CCD Photometry of bright stars using objective wire mesh
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamiński, Krzysztof; Zgórz, Marika; Schwarzenberg-Czerny, Aleksander, E-mail: chrisk@amu.edu.pl
2014-06-01
Obtaining accurate photometry of bright stars from the ground remains problematic due to the danger of overexposing the target and/or the lack of suitable nearby comparison stars. The century-old method of using objective wire mesh to produce multiple stellar images seems promising for the precise CCD photometry of such stars. Furthermore, our tests on β Cep and its comparison star, differing by 5 mag, are very encouraging. Using a CCD camera and a 20 cm telescope with the objective covered by a plastic wire mesh, in poor weather conditions, we obtained differential photometry with a precision of 4.5 mmag permore » two minute exposure. Our technique is flexible and may be tuned to cover a range as big as 6-8 mag. We discuss the possibility of installing a wire mesh directly in the filter wheel.« less
Cross-reacting carbohydrate determinants and hymenoptera venom allergy.
Brehler, Randolf; Grundmann, Sonja; Stöcker, Benedikt
2013-08-01
Insect venom allergy is an important cause of anaphylaxis. Venom immunotherapy assume the clear identification of the culprit insect, but this is impeded by Immunoglobulin E (IgE) antibodies to cross reactive carbohydrate determinant (CCD) epitopes of common glycoproteins. Here we give an overview about inducers, importance, and relevance of anti-N-Glycan CCD IgE antibodies. Pollen exposure and insect stings induce anti-CCD IgE antibodies interfering with in-vitro tests for allergy diagnosis due to extensive IgE cross-reactivity. Instead of being biologically active these antibodies are irrelevant for allergic reactions due to hymenoptera stings. The general response of the immune system to the ubiquitous exposure to N-glycan containing glycoproteins is still a matter of debate. CCD specific IgG antibodies in sera of bee keepers suggest tolerance induction due to high-dose exposure. Tolerance induction by pollen and food glycoproteins has not been proved. Hymenoptera stings and pollen exposure induce anti-CCD IgE. In regard to anaphylaxis due to Hymenoptera stings these antibodies are not clinically relevant, but they are important for the specificity of in-vitro tests proving insect venom allergy. The introduction of component based diagnostic IgE testing improves the specificity of in-vitro tests if proteins devoid of CCD epitopes are used.
Colony Collapse Disorder: A Descriptive Study
vanEngelsdorp, Dennis; Evans, Jay D.; Saegerman, Claude; Mullin, Chris; Haubruge, Eric; Nguyen, Bach Kim; Frazier, Maryann; Frazier, Jim; Cox-Foster, Diana; Chen, Yanping; Underwood, Robyn; Tarpy, David R.; Pettis, Jeffery S.
2009-01-01
Background Over the last two winters, there have been large-scale, unexplained losses of managed honey bee (Apis mellifera L.) colonies in the United States. In the absence of a known cause, this syndrome was named Colony Collapse Disorder (CCD) because the main trait was a rapid loss of adult worker bees. We initiated a descriptive epizootiological study in order to better characterize CCD and compare risk factor exposure between populations afflicted by and not afflicted by CCD. Methods and Principal Findings Of 61 quantified variables (including adult bee physiology, pathogen loads, and pesticide levels), no single measure emerged as a most-likely cause of CCD. Bees in CCD colonies had higher pathogen loads and were co-infected with a greater number of pathogens than control populations, suggesting either an increased exposure to pathogens or a reduced resistance of bees toward pathogens. Levels of the synthetic acaricide coumaphos (used by beekeepers to control the parasitic mite Varroa destructor) were higher in control colonies than CCD-affected colonies. Conclusions/Significance This is the first comprehensive survey of CCD-affected bee populations that suggests CCD involves an interaction between pathogens and other stress factors. We present evidence that this condition is contagious or the result of exposure to a common risk factor. Potentially important areas for future hypothesis-driven research, including the possible legacy effect of mite parasitism and the role of honey bee resistance to pesticides, are highlighted. PMID:19649264
Colony collapse disorder: a descriptive study.
Vanengelsdorp, Dennis; Evans, Jay D; Saegerman, Claude; Mullin, Chris; Haubruge, Eric; Nguyen, Bach Kim; Frazier, Maryann; Frazier, Jim; Cox-Foster, Diana; Chen, Yanping; Underwood, Robyn; Tarpy, David R; Pettis, Jeffery S
2009-08-03
Over the last two winters, there have been large-scale, unexplained losses of managed honey bee (Apis mellifera L.) colonies in the United States. In the absence of a known cause, this syndrome was named Colony Collapse Disorder (CCD) because the main trait was a rapid loss of adult worker bees. We initiated a descriptive epizootiological study in order to better characterize CCD and compare risk factor exposure between populations afflicted by and not afflicted by CCD. Of 61 quantified variables (including adult bee physiology, pathogen loads, and pesticide levels), no single measure emerged as a most-likely cause of CCD. Bees in CCD colonies had higher pathogen loads and were co-infected with a greater number of pathogens than control populations, suggesting either an increased exposure to pathogens or a reduced resistance of bees toward pathogens. Levels of the synthetic acaricide coumaphos (used by beekeepers to control the parasitic mite Varroa destructor) were higher in control colonies than CCD-affected colonies. This is the first comprehensive survey of CCD-affected bee populations that suggests CCD involves an interaction between pathogens and other stress factors. We present evidence that this condition is contagious or the result of exposure to a common risk factor. Potentially important areas for future hypothesis-driven research, including the possible legacy effect of mite parasitism and the role of honey bee resistance to pesticides, are highlighted.
Nonlinear time dependence of dark current in charge-coupled devices
NASA Astrophysics Data System (ADS)
Dunlap, Justin C.; Bodegom, Erik; Widenhorn, Ralf
2011-03-01
It is generally assumed that charge-coupled device (CCD) imagers produce a linear response of dark current versus exposure time except near saturation. We found a large number of pixels with nonlinear dark current response to exposure time to be present in two scientific CCD imagers. These pixels are found to exhibit distinguishable behavior with other analogous pixels and therefore can be characterized in groupings. Data from two Kodak CCD sensors are presented for exposure times from a few seconds up to two hours. Linear behavior is traditionally taken for granted when carrying out dark current correction and as a result, pixels with nonlinear behavior will be corrected inaccurately.
Portal imaging with flat-panel detector and CCD camera
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Tang, Chuankun; Cheng, Chee-Wai; Dallas, William J.
1997-07-01
This paper provides a comparison of imaging parameters of two portal imaging systems at 6 MV: a flat panel detector and a CCD-camera based portal imaging system. Measurements were made of the signal and noise and consequently of signal-to-noise per pixel as a function of the exposure. Both systems have a linear response with respect to exposure, and the noise is proportional to the square-root of the exposure, indicating photon-noise limitation. The flat-panel detector has a signal- to-noise ratio, which is higher than that observed wit the CCD-camera based portal imaging system. This is expected because most portal imaging systems using optical coupling with a lens exhibit severe quantum-sinks. The paper also presents data on the screen's photon gain (the number of light-photons per interacting x-ray photon), as well as on the magnitude of the Swank-noise, (which describes fluctuation in the screen's photon gain). Images of a Las Vegas-type aluminum contrast detail phantom, located at the ISO-Center, were generated at an exposure of 1 MU. The CCD-camera based system permits detection of aluminum-holes of 0.01194 cm diameter and 0.228 mm depth while the flat-panel detector permits detection of aluminum holes of 0.01194 cm diameter and 0.1626 mm depth, indicating a better signal-to-noise ratio. Rank order filtering was applied to the raw images from the CCD-based system in order to remove the direct hits. These are camera responses to scattered x-ray photons which interact directly with the CCD of the CCD-camera and generate 'salt and pepper type noise,' which interferes severely with attempts to determine accurate estimates of the image noise.
Flat-panel detector, CCD cameras, and electron-beam-tube-based video for use in portal imaging
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Tang, Chuankun; Cheng, Chee-Way; Dallas, William J.
1998-07-01
This paper provides a comparison of some imaging parameters of four portal imaging systems at 6 MV: a flat panel detector, two CCD cameras and an electron beam tube based video camera. Measurements were made of signal and noise and consequently of signal-to-noise per pixel as a function of the exposure. All systems have a linear response with respect to exposure, and with the exception of the electron beam tube based video camera, the noise is proportional to the square-root of the exposure, indicating photon-noise limitation. The flat-panel detector has a signal-to-noise ratio, which is higher than that observed with both CCD-Cameras or with the electron beam tube based video camera. This is expected because most portal imaging systems using optical coupling with a lens exhibit severe quantum-sinks. The measurements of signal-and noise were complemented by images of a Las Vegas-type aluminum contrast detail phantom, located at the ISO-Center. These images were generated at an exposure of 1 MU. The flat-panel detector permits detection of Aluminum holes of 1.2 mm diameter and 1.6 mm depth, indicating the best signal-to-noise ratio. The CCD-cameras rank second and third in signal-to- noise ratio, permitting detection of Aluminum-holes of 1.2 mm diameter and 2.2 mm depth (CCD_1) and of 1.2 mm diameter and 3.2 mm depth (CCD_2) respectively, while the electron beam tube based video camera permits detection of only a hole of 1.2 mm diameter and 4.6 mm depth. Rank Order Filtering was applied to the raw images from the CCD-based systems in order to remove the direct hits. These are camera responses to scattered x-ray photons which interact directly with the CCD of the CCD-Camera and generate 'Salt and Pepper type noise,' which interferes severely with attempts to determine accurate estimates of the image noise. The paper also presents data on the metal-phosphor's photon gain (the number of light-photons per interacting x-ray photon).
Development of Multiple-Element Flame Emission Spectrometer Using CCD Detection
ERIC Educational Resources Information Center
Seney, Caryn S.; Sinclair, Karen V.; Bright, Robin M.; Momoh, Paul O.; Bozeman, Amelia D.
2005-01-01
The full wavelength coverage of charge coupled device (CCD) detector when coupled with an echelle spectrography, the system allows for simultaneously multiple element spectroscopy to be performed. The multiple-element flame spectrometer was built and characterized through the analysis of environmentally significant elements such as Ca, K, Na, Cu,…
CCD Measurements of Double and Multiple Stars at NAO Rozhen and ASV in 2015
NASA Astrophysics Data System (ADS)
Cvetković, Z.; Pavlović, R.; Boeva, S.
2017-04-01
Results of CCD observations of 154 double or multiple stars, made with the 2 m telescope of the Bulgarian National Astronomical Observatory at Rozhen over five nights in 2015, are presented. This is the ninth series of measurements of CCD frames obtained at Rozhen. We also present results of CCD observations of 323 double or multiple stars made with the 0.6 m telescope of the Serbian Astronomical Station on the mountain of Vidojevica over 23 nights in 2015. This is the fourth series of measurements of CCD frames obtained at this station. This paper contains the results for the position angle and angular separation for 801 pairs and residuals for 127 pairs with published orbital elements or linear solutions. The angular separations are in the range from 1.″52 to 201.″56, with a median angular separation of 8.″26. We also present eight pairs that are measured for the first time and linear elements for five pairs.
NASA Technical Reports Server (NTRS)
Halama, G.; McAdoo, J.; Liu, H.
1998-01-01
To demonstrate the feasibility of a novel large-field digital mammography technique, a 1024 x 1024 pixel Loral charge-coupled device (CCD) focal plane array (FPA) was positioned in a mammographic field with one- and two-dimensional scan sequences to obtain 950 x 1800 pixel and 3600 x 3600 pixel composite images, respectively. These experiments verify that precise positioning of FPAs produced seamless composites and that the CCD mosaic concept has potential for high-resolution, large-field imaging. The proposed CCD mosaic concept resembles a checkerboard pattern with spacing left between the CCDs for the driver and readout electronics. To obtain a complete x-ray image, the mosaic must be repositioned four times, with an x-ray exposure at each position. To reduce the patient dose, a lead shield with appropriately patterned holes is placed between the x-ray source and the patient. The high-precision motorized translation stages and the fiber-coupled-scintillating-screen-CCD sensor assembly were placed in the position usually occupied by the film cassette. Because of the high mechanical precision, seamless composites were constructed from the subimages. This paper discusses the positioning, image alignment procedure, and composite image results. The paper only addresses the formation of a seamless composite image from subimages and will not consider the effects of the lead shield, multiple CCDs, or the speed of motion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finch, Charlie T.; Zacharias, Norbert; Wycoff, Gary L., E-mail: finch@usno.navy.mi
2010-06-15
Presented here are the details of the astrometric reductions from the x, y data to mean right ascension (R.A.), declination (decl.) coordinates of the third U.S. Naval Observatory CCD Astrograph Catalog (UCAC3). For these new reductions we used over 216,000 CCD exposures. The Two-Micron All-Sky Survey (2MASS) data are used extensively to probe for coordinate and coma-like systematic errors in UCAC data mainly caused by the poor charge transfer efficiency of the 4K CCD. Errors up to about 200 mas have been corrected using complex look-up tables handling multiple dependences derived from the residuals. Similarly, field distortions and sub-pixel phasemore » errors have also been evaluated using the residuals with respect to 2MASS. The overall magnitude equation is derived from UCAC calibration field observations alone, independent of external catalogs. Systematic errors of positions at the UCAC observing epoch as presented in UCAC3 are better corrected than in the previous catalogs for most stars. The Tycho-2 catalog is used to obtain final positions on the International Celestial Reference Frame. Residuals of the Tycho-2 reference stars show a small magnitude equation (depending on declination zone) that might be inherent in the Tycho-2 catalog.« less
Design of system calibration for effective imaging
NASA Astrophysics Data System (ADS)
Varaprasad Babu, G.; Rao, K. M. M.
2006-12-01
A CCD based characterization setup comprising of a light source, CCD linear array, Electronics for signal conditioning/ amplification, PC interface has been developed to generate images at varying densities and at multiple view angles. This arrangement is used to simulate and evaluate images by Super Resolution technique with multiple overlaps and yaw rotated images at different view angles. This setup also generates images at different densities to analyze the response of the detector port wise separately. The light intensity produced by the source needs to be calibrated for proper imaging by the high sensitive CCD detector over the FOV. One approach is to design a complex integrating sphere arrangement which costs higher for such applications. Another approach is to provide a suitable intensity feed back correction wherein the current through the lamp is controlled in a closed loop arrangement. This method is generally used in the applications where the light source is a point source. The third method is to control the time of exposure inversely to the lamp variations where lamp intensity is not possible to control. In this method, light intensity during the start of each line is sampled and the correction factor is applied for the full line. The fourth method is to provide correction through Look Up Table where the response of all the detectors are normalized through the digital transfer function. The fifth method is to have a light line arrangement where the light through multiple fiber optic cables are derived from a single source and arranged them in line. This is generally applicable and economical for low width cases. In our applications, a new method wherein an inverse multi density filter is designed which provides an effective calibration for the full swath even at low light intensities. The light intensity along the length is measured, an inverse density is computed, a correction filter is generated and implemented in the CCD based Characterization setup. This paper describes certain novel techniques of design and implementation of system calibration for effective Imaging to produce better quality data product especially while handling high resolution data.
NASA Technical Reports Server (NTRS)
Hewes, C. R.; Bosshart, P. W.; Eversole, W. L.; Dewit, M.; Buss, D. D.
1976-01-01
Two CCD techniques were discussed for performing an N-point sampled data correlation between an input signal and an electronically programmable reference function. The design and experimental performance of an implementation of the direct time correlator utilizing two analog CCDs and MOS multipliers on a single IC were evaluated. The performance of a CCD implementation of the chirp z transform was described, and the design of a new CCD integrated circuit for performing correlation by multiplication in the frequency domain was presented. This chip provides a discrete Fourier transform (DFT) or inverse DFT, multipliers, and complete support circuitry for the CCD CZT. The two correlation techniques are compared.
Sun, Steven; Francis, Jesse; Sapsford, Kim E.; Kostov, Yordan; Rasooly, Avraham
2010-01-01
A portable and rapid detection system for the activity analysis of Botulinum Neurotoxins (BoNT) is needed for food safety and bio-security applications. To improve BoNT activity detection, a previously designed portable charge-coupled device (CCD) based detector was modified and equipped with a higher intensity more versatile multi-wavelength spatial light-emitting diode (LED) illumination, a faster CCD detector and the capability to simultaneously detect 30 samples. A FITC/DABCYL Förster Resonance Energy Transfer (FRET)-labeled peptide substrate (SNAP-25), with BoNT-A target cleavage site sequence was used to measure BoNT-A light chain (LcA) activity through the FITC fluorescence increase that occurs upon peptide substrate cleavage. For fluorescence excitation, a multi-wavelength spatial LED illuminator was used and compared to our previous electroluminescent (EL) strips. The LED illuminator was equipped with blue, green, red and white LEDs, covering a spectrum of 450-680 nm (red 610-650 nm, green 492-550 nm, blue 450-495 nm, and white LED 440-680 nm). In terms of light intensity, the blue LED was found to be ~80 fold higher than the previously used blue EL strips. When measuring the activity of LcA the CCD detector limit of detection (LOD) was found to be 0.08 nM LcA for both the blue LED (2 s exposure) and the blue EL (which require ≥60 s exposure) while the limits of quantitation (LOQ) is about 1 nM. The LOD for white LED was higher at 1.4 nM while the white EL was not used for the assay due to a high variable background. Unlike the weaker intensity EL illumination the high intensity LED illumination enabled shorter exposure times and allowed multi-wavelength illumination without the need to physically change the excitation strip, thus making spectrum excitation of multiple fluorophores possible increasing the versatility of the detector platform for a variety of optical detection assays. PMID:20498728
Modeling colony collapse disorder in honeybees as a contagion.
Kribs-Zaleta, Christopher M; Mitchell, Christopher
2014-12-01
Honeybee pollination accounts annually for over $14 billion in United States agriculture alone. Within the past decade there has been a mysterious mass die-off of honeybees, an estimated 10 million beehives and sometimes as much as 90% of an apiary. There is still no consensus on what causes this phenomenon, called Colony Collapse Disorder, or CCD. Several mathematical models have studied CCD by only focusing on infection dynamics. We created a model to account for both healthy hive dynamics and hive extinction due to CCD, modeling CCD via a transmissible infection brought to the hive by foragers. The system of three ordinary differential equations accounts for multiple hive population behaviors including Allee effects and colony collapse. Numerical analysis leads to critical hive sizes for multiple scenarios and highlights the role of accelerated forager recruitment in emptying hives during colony collapse.
NASA Astrophysics Data System (ADS)
Anton, Rainer
2011-04-01
Using a 50cm Cassegrain in Namibia, recordings of double and multiple stars were made with a fast CCD camera and a notebook computer. From superpositions of "lucky images", measurements of 149 systems were obtained and compared with literature data. B/W and color images of some remarkable systems are also presented.
NASA Astrophysics Data System (ADS)
Anton, Rainer
2010-07-01
Using a 10" Newtonian and a fast CCD camera, recordings of double and multiple stars were made at high frame rates with a notebook computer. From superpositions of "lucky images", measurements of 139 systems were obtained and compared with literature data. B/w and color images of some noteworthy systems are also presented.
VizieR Online Data Catalog: Photometry of multiple stars at NAOR&ASV in 2015 (Cvetkovic+, 2017)
NASA Astrophysics Data System (ADS)
Cvetkovic, Z.; Pavlovic, R.; Boeva, S.
2018-05-01
This is the ninth series of CCD observations of double and multiple stars, obtained at the Bulgarian National Astronomical Observatory at Rozhen (NAOR) over five nights. As previously, the CCD camera VersArray 1300B was used, which was attached to the 2 m telescope. For each double or multiple star, five CCD frames in the Johnson B filter and five frames in the Johnson V filter were taken, which enabled us to determine the magnitude difference for these filters. In 2015 at the Astronomical Station at Vidojevica (ASV), over a total of 23 nights, observations were carried out by using the 60 cm telescope with a Cassegrain optical system. This is the fourth observational series at ASV since the work started there in 2011. In the observations we used the Apogee Alta U42 CCD camera whose characteristics can be found in the paper by Cvetkovic et al. (2016, J/AJ/151/58). Every pair was observed five times in the Cousins/Bessel B filter and five times in the Cousins/Bessel V one. (3 data files).
SU-F-T-180: Evaluation of a Scintillating Screen Detector for Proton Beam QA and Acceptance Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghebremedhin, A; Taber, M; Koss, P
2016-06-15
Purpose: To test the performance of a commercial scintillating screen detector for acceptance testing and Quality Assurance of a proton pencil beam scanning system. Method: The detector (Lexitek DRD 400) has 40cm × 40cm field, uses a thin scintillator imaged onto a 16-bit scientific CCD with ∼0.5mm resolution. A grid target and LED illuminators are provided for spatial calibration and relative gain correction. The detector mounts to the nozzle with micron precision. Tools are provided for image processing and analysis of single or multiple Gaussian spots. Results: The bias and gain of the detector were studied to measure repeatability andmore » accuracy. Gain measurements were taken with the LED illuminators to measure repeatability and variation of the lens-CCD pair as a function with f-stop. Overall system gain was measured with a passive scattering (broad) beam whose shape is calibrated with EDR film placed in front of the scintillator. To create a large uniform field, overlapping small fields were recorded with the detector translated laterally and stitched together to cover the full field. Due to the long exposures required to obtain multiple spills of the synchrotron and very high detector sensitivity, borated polyethylene shielding was added to reduce direct radiation events hitting the CCD. Measurements with a micro ion chamber were compared to the detector’s spot profile. Software was developed to process arrays of Gaussian spots and to correct for radiation events. Conclusion: The detector background has a fixed bias, a small component linear in time, and is easily corrected. The gain correction method was validated with 2% accuracy. The detector spot profile matches the micro ion chamber data over 4 orders of magnitude. The multiple spot analyses can be easily used with plan data for measuring pencil beam uniformity and for regular QA comparison.« less
Phase retrieval without unwrapping by single-shot dual-wavelength digital holography
NASA Astrophysics Data System (ADS)
Min, Junwei; Yao, Baoli; Zhou, Meiling; Guo, Rongli; Lei, Ming; Yang, Yanlong; Dan, Dan; Yan, Shaohui; Peng, Tong
2014-12-01
A phase retrieval method by using single-shot dual-wavelength digital holography is proposed. Each single wavelength hologram is extracted from the color CCD recorded hologram at one exposure, and the unwrapped phase image of object can be reconstructed directly. Different from the traditional multiple wavelength phase unwrapping techniques, any single complex wave-fronts at different wavelengths have no need to be calculated any more. Thus, the phase retrieval is computationally fast and straightforward, and the limitations on the total optical path difference are significantly relaxed. The practicability of the proposed method is demonstrated by both simulated and experimental results.
NASA Technical Reports Server (NTRS)
Bathel, Brett F.; Danehy, Paul M.; Inmian, Jennifer A.; Jones, Stephen B.; Ivey, Christopher B.; Goyne, Christopher P.
2010-01-01
Nitric-oxide planar laser-induced fluorescence (NO PLIF) was used to perform velocity measurements in hypersonic flows by generating multiple tagged lines which fluoresce as they convect downstream. For each laser pulse, a single interline, progressive scan intensified CCD camera was used to obtain separate images of the initial undelayed and delayed NO molecules that had been tagged by the laser. The CCD configuration allowed for sub-microsecond acquisition of both images, resulting in sub-microsecond temporal resolution as well as sub-mm spatial resolution (0.5-mm x 0.7-mm). Determination of axial velocity was made by application of a cross-correlation analysis of the horizontal shift of individual tagged lines. Quantification of systematic errors, the contribution of gating/exposure duration errors, and influence of collision rate on fluorescence to temporal uncertainty were made. Quantification of the spatial uncertainty depended upon the analysis technique and signal-to-noise of the acquired profiles. This investigation focused on two hypersonic flow experiments: (1) a reaction control system (RCS) jet on an Orion Crew Exploration Vehicle (CEV) wind tunnel model and (2) a 10-degree half-angle wedge containing a 2-mm tall, 4-mm wide cylindrical boundary layer trip. The experiments were performed at the NASA Langley Research Center's 31-inch Mach 10 wind tunnel.
Stock, David; Paszat, Lawrence F; Rabeneck, Linda
2016-07-01
Colonoscopy has been demonstrated to be effective in colorectal cancer (CRC) mortality reduction, although current screening guidelines have yet to be evaluated. We assessed the protective benefit of colonoscopy within the previous 10 years and whether this effect is maintained with age. We used administrative data to compare risk of CRC death (CCD) across colonoscopy utilization among a population-wide cohort comprising individuals aged 60 to 80 years (N = 1,509,423). Baseline and time-dependent colonoscopy exposure models were assessed in the context of competing "other causes of death" (OCDs). Cumulative incidence of CCD and OCD across colonoscopy exposure, over follow-up, was estimated. Relative hazards were computed by age strata (60-69 years, 70-74 years, 75+ years) and proximal and distal cancer subsites. At least 1 colonoscopy during 10 years before baseline was estimated to provide a 51% reduced hazard of CCD (hazard ratio [HR] 0.49; 95% confidence interval [CI], 0.45-0.54) over the following 8 years. When colonoscopy was modeled as a time-dependent covariate, the risk of CCD was further diminished (multivariable-adjusted HR 0.36; 95% CI, 0.33-0.38). Stratified analyses suggested moderately attenuated CCD risk reduction among the oldest age group; however, consideration of OCDs suggest that this is related to competing risks. CCD risk reduction related to colonoscopy was lower for proximal cancers. Colonoscopy within the previous 10 years provides substantial protective benefit for average-risk individuals over 60 years. CCD risk reduction may be maintained well beyond 74 years, a common upper age limit recommended by screening guidelines. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Soft X-ray and XUV imaging with a charge-coupled device /CCD/-based detector
NASA Technical Reports Server (NTRS)
Loter, N. G.; Burstein, P.; Krieger, A.; Ross, D.; Harrison, D.; Michels, D. J.
1981-01-01
A soft X-ray/XUV imaging camera which uses a thinned, back-illuminated, all-buried channel RCA CCD for radiation sensing has been built and tested. The camera is a slow-scan device which makes possible frame integration if necessary. The detection characteristics of the device have been tested over the 15-1500 eV range. The response was linear with exposure up to 0.2-0.4 erg/sq cm; saturation occurred at greater exposures. Attention is given to attempts to resolve single photons with energies of 1.5 keV.
Signal processing applications of massively parallel charge domain computing devices
NASA Technical Reports Server (NTRS)
Fijany, Amir (Inventor); Barhen, Jacob (Inventor); Toomarian, Nikzad (Inventor)
1999-01-01
The present invention is embodied in a charge coupled device (CCD)/charge injection device (CID) architecture capable of performing a Fourier transform by simultaneous matrix vector multiplication (MVM) operations in respective plural CCD/CID arrays in parallel in O(1) steps. For example, in one embodiment, a first CCD/CID array stores charge packets representing a first matrix operator based upon permutations of a Hartley transform and computes the Fourier transform of an incoming vector. A second CCD/CID array stores charge packets representing a second matrix operator based upon different permutations of a Hartley transform and computes the Fourier transform of an incoming vector. The incoming vector is applied to the inputs of the two CCD/CID arrays simultaneously, and the real and imaginary parts of the Fourier transform are produced simultaneously in the time required to perform a single MVM operation in a CCD/CID array.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goddu, S; Sun, B; Grantham, K
2016-06-15
Purpose: Proton therapy (PT) delivery is complex and extremely dynamic. Therefore, quality assurance testing is vital, but highly time-consuming. We have developed a High-Speed Scintillation-Camera-System (HS-SCS) for simultaneously measuring multiple beam characteristics. Methods: High-speed camera was placed in a light-tight housing and dual-layer neutron shield. HS-SCS is synchronized with a synchrocyclotron to capture individual proton-beam-pulses (PBPs) at ∼504 frames/sec. The PBPs from synchrocyclotron trigger the HS-SCS to open its shutter for programmed exposure-time. Light emissions within 30×30×5cm3 plastic-scintillator (BC-408) were captured by a CCD-camera as individual images revealing dose-deposition in a 2D-plane with a resolution of 0.7mm for range andmore » SOBP measurements and 1.67mm for profiles. The CCD response as well as signal to noise ratio (SNR) was characterized for varying exposure times, gains for different light intensities using a TV-Optoliner system. Software tools were developed to analyze ∼5000 images to extract different beam parameters. Quenching correction-factors were established by comparing scintillation Bragg-Peaks with water scanned ionization-chamber measurements. Quenching corrected Bragg-peaks were integrated to ascertain proton-beam range (PBR), width of Spared-Out-Bragg-Peak (MOD) and distal.« less
Mosaic CCD method: A new technique for observing dynamics of cometary magnetospheres
NASA Technical Reports Server (NTRS)
Saito, T.; Takeuchi, H.; Kozuba, Y.; Okamura, S.; Konno, I.; Hamabe, M.; Aoki, T.; Minami, S.; Isobe, S.
1992-01-01
On April 29, 1990, the plasma tail of Comet Austin was observed with a CCD camera on the 105-cm Schmidt telescope at the Kiso Observatory of the University of Tokyo. The area of the CCD used in this observation is only about 1 sq cm. When this CCD is used on the 105-cm Schmidt telescope at the Kiso Observatory, the area corresponds to a narrow square view of 12 ft x 12 ft. By comparison with the photograph of Comet Austin taken by Numazawa (personal communication) on the same night, we see that only a small part of the plasma tail can be photographed at one time with the CCD. However, by shifting the view on the CCD after each exposure, we succeeded in imaging the entire length of the cometary magnetosphere of 1.6 x 10(exp 6) km. This new technique is called 'the mosaic CCD method'. In order to study the dynamics of cometary plasma tails, seven frames of the comet from the head to the tail region were twice imaged with the mosaic CCD method and two sets of images were obtained. Six microstructures, including arcade structures, were identified in both the images. Sketches of the plasma tail including microstructures are included.
Granero, Luis; Zalevsky, Zeev; Micó, Vicente
2011-04-01
We present a new implementation capable of producing two-dimensional (2D) superresolution (SR) imaging in a single exposure by aperture synthesis in digital lensless Fourier holography when using angular multiplexing provided by a vertical cavity surface-emitting laser source array. The system performs the recording in a single CCD snapshot of a multiplexed hologram coming from the incoherent addition of multiple subholograms, where each contains information about a different 2D spatial frequency band of the object's spectrum. Thus, a set of nonoverlapping bandpass images of the input object can be recovered by Fourier transformation (FT) of the multiplexed hologram. The SR is obtained by coherent addition of the information contained in each bandpass image while generating an enlarged synthetic aperture. Experimental results demonstrate improvement in resolution and image quality.
Bottenberg, Peter; Jacquet, Wolfgang; Stachniss, Vitus; Wellnitz, Johann; Schulte, Andreas G
2011-04-01
To determine the ability of digital sensors (CMOS and CCD sensors) and D and F-speed films to detect cavitated and non-cavitated enamel caries lesions at different exposure conditions compared to a gold standard. 100 extracted human molars and premolars were selected and mounted in a block between two neighboring teeth. Sensors or films were exposed with voltages of 60 or 70 kVp at varying times. Three observers assessed each approximal site independently. Lesion depth was rated according to an anatomical five-point scale (0 = no lesion to 4 = lesion reaching inner half of dentin). Serial sections of resin-embedded teeth were prepared. Gold-standard scores were established by consensus based on histological sectioning. A carious lesion was present at scores of 1 and higher. Statistical evaluation (sensitivity, specificity and receiver-operating curves) was based on caries-free surfaces and those presenting enamel caries (n=116). The ROC curves had "area under the curve" values (Az) from 0.50 (F-speed, 70 kVp, 0.20 seconds) to 0.58 (CCD 60 kVp, 0.08 seconds). The detection percentage of cavitated lesions was generally higher (0-52%, depending on technique and observer) than that of non-cavitated lesions (3-32%). The CMOS sensor showed Az values comparable to the CCD sensors but required higher exposure times. There was no significant difference between 60 and 70 kVp.
Targeting excited states in all-trans polyenes with electron-pair states.
Boguslawski, Katharina
2016-12-21
Wavefunctions restricted to electron pair states are promising models for strongly correlated systems. Specifically, the pair Coupled Cluster Doubles (pCCD) ansatz allows us to accurately describe bond dissociation processes and heavy-element containing compounds with multiple quasi-degenerate single-particle states. Here, we extend the pCCD method to model excited states using the equation of motion (EOM) formalism. As the cluster operator of pCCD is restricted to electron-pair excitations, EOM-pCCD allows us to target excited electron-pair states only. To model singly excited states within EOM-pCCD, we modify the configuration interaction ansatz of EOM-pCCD to contain also single excitations. Our proposed model represents a simple and cost-effective alternative to conventional EOM-CC methods to study singly excited electronic states. The performance of the excited state models is assessed against the lowest-lying excited states of the uranyl cation and the two lowest-lying excited states of all-trans polyenes. Our numerical results suggest that EOM-pCCD including single excitations is a good starting point to target singly excited states.
Pathogen webs in collapsing honey bee colonies.
Cornman, R Scott; Tarpy, David R; Chen, Yanping; Jeffreys, Lacey; Lopez, Dawn; Pettis, Jeffery S; vanEngelsdorp, Dennis; Evans, Jay D
2012-01-01
Recent losses in honey bee colonies are unusual in their severity, geographical distribution, and, in some cases, failure to present recognized characteristics of known disease. Domesticated honey bees face numerous pests and pathogens, tempting hypotheses that colony collapses arise from exposure to new or resurgent pathogens. Here we explore the incidence and abundance of currently known honey bee pathogens in colonies suffering from Colony Collapse Disorder (CCD), otherwise weak colonies, and strong colonies from across the United States. Although pathogen identities differed between the eastern and western United States, there was a greater incidence and abundance of pathogens in CCD colonies. Pathogen loads were highly covariant in CCD but not control hives, suggesting that CCD colonies rapidly become susceptible to a diverse set of pathogens, or that co-infections can act synergistically to produce the rapid depletion of workers that characterizes the disorder. We also tested workers from a CCD-free apiary to confirm that significant positive correlations among pathogen loads can develop at the level of individual bees and not merely as a secondary effect of CCD. This observation and other recent data highlight pathogen interactions as important components of bee disease. Finally, we used deep RNA sequencing to further characterize microbial diversity in CCD and non-CCD hives. We identified novel strains of the recently described Lake Sinai viruses (LSV) and found evidence of a shift in gut bacterial composition that may be a biomarker of CCD. The results are discussed with respect to host-parasite interactions and other environmental stressors of honey bees.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Su, Minfei; Li, Yue; Wyborny, Shane
ATG14 binding to BECN/Beclin homologs is essential for autophagy, a critical catabolic homeostasis pathway. Here, we show that the α-helical, coiled-coil domain (CCD) of BECN2, a recently identified mammalian BECN1 paralog, forms an antiparallel, curved homodimer with seven pairs of nonideal packing interactions, while the BECN2 CCD and ATG14 CCD form a parallel, curved heterodimer stabilized by multiple, conserved polar interactions. Compared to BECN1, the BECN2 CCD forms a weaker homodimer, but binds more tightly to the ATG14 CCD. Mutation of nonideal BECN2 interface residues to more ideal pairs improves homodimer self-association and thermal stability. Unlike BECN1, all BECN2 CCDmore » mutants bind ATG14, although more weakly than wild type. Thus, polar BECN2 CCD interface residues result in a metastable homodimer, facilitating dissociation, but enable better interactions with polar ATG14 residues stabilizing the BECN2:ATG14 heterodimer. These structure-based mechanistic differences in BECN1 and BECN2 homodimerization and heterodimerization likely dictate competitive ATG14 recruitment.« less
Event-Driven Random-Access-Windowing CCD Imaging System
NASA Technical Reports Server (NTRS)
Monacos, Steve; Portillo, Angel; Ortiz, Gerardo; Alexander, James; Lam, Raymond; Liu, William
2004-01-01
A charge-coupled-device (CCD) based high-speed imaging system, called a realtime, event-driven (RARE) camera, is undergoing development. This camera is capable of readout from multiple subwindows [also known as regions of interest (ROIs)] within the CCD field of view. Both the sizes and the locations of the ROIs can be controlled in real time and can be changed at the camera frame rate. The predecessor of this camera was described in High-Frame-Rate CCD Camera Having Subwindow Capability (NPO- 30564) NASA Tech Briefs, Vol. 26, No. 12 (December 2002), page 26. The architecture of the prior camera requires tight coupling between camera control logic and an external host computer that provides commands for camera operation and processes pixels from the camera. This tight coupling limits the attainable frame rate and functionality of the camera. The design of the present camera loosens this coupling to increase the achievable frame rate and functionality. From a host computer perspective, the readout operation in the prior camera was defined on a per-line basis; in this camera, it is defined on a per-ROI basis. In addition, the camera includes internal timing circuitry. This combination of features enables real-time, event-driven operation for adaptive control of the camera. Hence, this camera is well suited for applications requiring autonomous control of multiple ROIs to track multiple targets moving throughout the CCD field of view. Additionally, by eliminating the need for control intervention by the host computer during the pixel readout, the present design reduces ROI-readout times to attain higher frame rates. This camera (see figure) includes an imager card consisting of a commercial CCD imager and two signal-processor chips. The imager card converts transistor/ transistor-logic (TTL)-level signals from a field programmable gate array (FPGA) controller card. These signals are transmitted to the imager card via a low-voltage differential signaling (LVDS) cable assembly. The FPGA controller card is connected to the host computer via a standard peripheral component interface (PCI).
Familial cleidocranial dysplasia misdiagnosed as rickets over three generations.
Franceschi, Roberto; Maines, Evelina; Fedrizzi, Michela; Piemontese, Maria Rosaria; De Bonis, Patrizia; Agarwal, Nivedita; Bellizzi, Maria; Di Palma, Annunziata
2015-10-01
Cleidocranial dysplasia (CCD) is a rare autosomal dominant skeletal dysplasia characterized by hypoplastic clavicles, late closure of the fontanels, dental problems and other skeletal features. CCD is caused by mutations, deletions or duplications in runt-related transcription factor 2 (RUNX2), which encodes for a protein essential for osteoblast differentiation and chondrocyte maturation. We describe three familial cases of CCD, misdiagnosed as rickets over three generations. No mutations were detected on standard DNA sequencing of RUNX2, but a novel deletion was identified on quantitative polymerase chain reaction (qPCR) and multiple ligation-dependent probe amplification (MLPA). The present cases indicate that CCD could be misdiagnosed as rickets, leading to inappropriate treatment, and confirm that mutations in RUNX2 are not able to be identified on standard DNA sequencing in all CCD patients, but can be identified on qPCR and MLPA. © 2015 Japan Pediatric Society.
Pathogen Webs in Collapsing Honey Bee Colonies
Cornman, R. Scott; Tarpy, David R.; Chen, Yanping; Jeffreys, Lacey; Lopez, Dawn; Pettis, Jeffery S.; vanEngelsdorp, Dennis; Evans, Jay D.
2012-01-01
Recent losses in honey bee colonies are unusual in their severity, geographical distribution, and, in some cases, failure to present recognized characteristics of known disease. Domesticated honey bees face numerous pests and pathogens, tempting hypotheses that colony collapses arise from exposure to new or resurgent pathogens. Here we explore the incidence and abundance of currently known honey bee pathogens in colonies suffering from Colony Collapse Disorder (CCD), otherwise weak colonies, and strong colonies from across the United States. Although pathogen identities differed between the eastern and western United States, there was a greater incidence and abundance of pathogens in CCD colonies. Pathogen loads were highly covariant in CCD but not control hives, suggesting that CCD colonies rapidly become susceptible to a diverse set of pathogens, or that co-infections can act synergistically to produce the rapid depletion of workers that characterizes the disorder. We also tested workers from a CCD-free apiary to confirm that significant positive correlations among pathogen loads can develop at the level of individual bees and not merely as a secondary effect of CCD. This observation and other recent data highlight pathogen interactions as important components of bee disease. Finally, we used deep RNA sequencing to further characterize microbial diversity in CCD and non-CCD hives. We identified novel strains of the recently described Lake Sinai viruses (LSV) and found evidence of a shift in gut bacterial composition that may be a biomarker of CCD. The results are discussed with respect to host-parasite interactions and other environmental stressors of honey bees. PMID:22927991
ERIC Educational Resources Information Center
Edgecombe, Nikki; Jaggars, Shanna Smith; Baker, Elaine DeLott; Bailey, Thomas
2013-01-01
Originally designed for students who test into at least two levels of developmental education in a particular subject area, FastStart is a compressed course program model launched in 2005 at the Community College of Denver (CCD). The program combines multiple semester-length courses into a single intensive semester, while providing case…
Multiple-target tracking implementation in the ebCMOS camera system: the LUSIPHER prototype
NASA Astrophysics Data System (ADS)
Doan, Quang Tuyen; Barbier, Remi; Dominjon, Agnes; Cajgfinger, Thomas; Guerin, Cyrille
2012-06-01
The domain of the low light imaging systems progresses very fast, thanks to detection and electronic multiplication technology evolution, such as the emCCD (electron multiplying CCD) or the ebCMOS (electron bombarded CMOS). We present an ebCMOS camera system that is able to track every 2 ms more than 2000 targets with a mean number of photons per target lower than two. The point light sources (targets) are spots generated by a microlens array (Shack-Hartmann) used in adaptive optics. The Multiple-Target-Tracking designed and implemented on a rugged workstation is described. The results and the performances of the system on the identification and tracking are presented and discussed.
Degradation of optical components in space
NASA Technical Reports Server (NTRS)
Blue, M. D.
1993-01-01
This report concerns two types of optical components: multilayer filters and mirrors, and self-scanned imaging arrays using charge coupled device (CCD) readouts. For the filters and mirrors, contamination produces a strong reduction in transmittance in the ultraviolet spectral region, but has little or no effect in the visible and infrared spectral regions. Soft substrates containing halides are unsatisfactory as windows or substrates. Materials choice for dielectric layers should also reflect such considerations. Best performance is also found for the harder materials. Compaction of the layers and interlayer diffusion causes a blue shift in center wavelength and loss of throughput. For sensors using CCD's, shifts in gate voltage and reductions in transfer efficiency occur. Such effects in CCD's are in accord with expectations of the effects of the radiation dose on the device. Except for optical fiber, degradation of CCD's represents the only ionizing-radiation induced effect on the Long Duration Exposure Facility (LDEF) optical systems components that has been observed.
Ramachandra, Ranjan; Bouwer, James C; Mackey, Mason R; Bushong, Eric; Peltier, Steven T; Xuong, Nguyen-Huu; Ellisman, Mark H
2014-06-01
Energy filtered transmission electron microscopy techniques are regularly used to build elemental maps of spatially distributed nanoparticles in materials and biological specimens. When working with thick biological sections, electron energy loss spectroscopy techniques involving core-loss electrons often require exposures exceeding several minutes to provide sufficient signal to noise. Image quality with these long exposures is often compromised by specimen drift, which results in blurring and reduced resolution. To mitigate drift artifacts, a series of short exposure images can be acquired, aligned, and merged to form a single image. For samples where the target elements have extremely low signal yields, the use of charge coupled device (CCD)-based detectors for this purpose can be problematic. At short acquisition times, the images produced by CCDs can be noisy and may contain fixed pattern artifacts that impact subsequent correlative alignment. Here we report on the use of direct electron detection devices (DDD's) to increase the signal to noise as compared with CCD's. A 3× improvement in signal is reported with a DDD versus a comparably formatted CCD, with equivalent dose on each detector. With the fast rolling-readout design of the DDD, the duty cycle provides a major benefit, as there is no dead time between successive frames.
The Multi-site All-Sky CAmeRA (MASCARA). Finding transiting exoplanets around bright (mV < 8) stars
NASA Astrophysics Data System (ADS)
Talens, G. J. J.; Spronck, J. F. P.; Lesage, A.-L.; Otten, G. P. P. L.; Stuik, R.; Pollacco, D.; Snellen, I. A. G.
2017-05-01
This paper describes the design, operations, and performance of the Multi-site All-Sky CAmeRA (MASCARA). Its primary goal is to find new exoplanets transiting bright stars, 4 < mV < 8, by monitoring the full sky. MASCARA consists of one northern station on La Palma, Canary Islands (fully operational since February 2015), one southern station at La Silla Observatory, Chile (operational from early 2017), and a data centre at Leiden Observatory in the Netherlands. Both MASCARA stations are equipped with five interline CCD cameras using wide field lenses (24 mm focal length) with fixed pointings, which together provide coverage down to airmass 3 of the local sky. The interline CCD cameras allow for back-to-back exposures, taken at fixed sidereal times with exposure times of 6.4 sidereal seconds. The exposures are short enough that the motion of stars across the CCD does not exceed one pixel during an integration. Astrometry and photometry are performed on-site, after which the resulting light curves are transferred to Leiden for further analysis. The final MASCARA archive will contain light curves for 70 000 stars down to mV = 8.4, with a precision of 1.5% per 5 minutes at mV = 8.
NASA Technical Reports Server (NTRS)
Bathel, Brett F.; Danehy, Paul M.; Inman, Jennifer A.; Jones, Stephen B.; Ivey,Christopher b.; Goyne, Christopher P.
2010-01-01
Nitric-oxide planar laser-induced fluorescence (NO PLIF) was used to perform velocity measurements in hypersonic flows by generating multiple tagged lines which fluoresce as they convect downstream. For each laser pulse, a single interline, progressive scan intensified CCD (charge-coupled device) camera was used to obtain two sequential images of the NO molecules that had been tagged by the laser. The CCD configuration allowed for sub-microsecond acquisition of both images, resulting in sub-microsecond temporal resolution as well as sub-mm spatial resolution (0.5-mm horizontal, 0.7-mm vertical). Determination of axial velocity was made by application of a cross-correlation analysis of the horizontal shift of individual tagged lines. A numerical study of measured velocity error due to a uniform and linearly-varying collisional rate distribution was performed. Quantification of systematic errors, the contribution of gating/exposure duration errors, and the influence of collision rate on temporal uncertainty were made. Quantification of the spatial uncertainty depended upon the signal-to-noise ratio of the acquired profiles. This velocity measurement technique has been demonstrated for two hypersonic flow experiments: (1) a reaction control system (RCS) jet on an Orion Crew Exploration Vehicle (CEV) wind tunnel model and (2) a 10-degree half-angle wedge containing a 2-mm tall, 4-mm wide cylindrical boundary layer trip. The experiments were performed at the NASA Langley Research Center's 31-Inch Mach 10 Air Tunnel.
Anissi, H D; Geibel, M A
2014-08-01
The purpose of this study was to gain insight into the distribution and application of digital intraoral radiographic techniques within general dental practices and to compare these with film-based systems in terms of patient dose reduction. 1100 questionnaires were handed out to general dental practitioners. Data was analyzed with respect to the type of system by using descriptive statistics and nonparametric tests, i.e. Kruskal-Wallis, Mann-Whitney and chi-square test (SPSS 20). 64% of the questioned dentists still use film-based radiology, 23% utilize storage phosphor plate (SPP) systems and 13% use a charge-coupled device (CCD). A strong correlation between the number of dentists working in a practice and the use of digital dental imaging was observed. Almost 3/4 of the film users work with E- or F-speed film. 45% of them refuse to change to a digital system. The use of lead aprons was popular, while only a minority preferred thyroid shields and rectangular collimators. A fourfold reduction of exposure time from D-speed film to CCD systems was observed. Due to detector size and positioning errors, users of CCD systems take significantly more single-tooth radiographs in total. Considering the number of radiographs per patient, there is only a slight tendency towards more X-rays with CCD systems. Up to image generation, digital systems seem to be as or even more difficult to handle than film-based systems, while their handling was favored after radiographic exposure. Despite a slight increase of radiographs taken with CCD systems, there is a significant dosage reduction. Corresponding to the decrease in exposure time, the patient dose for SPP systems is reduced to one half compared to film. The main issues in CCD technology are positioning errors and the size of the X-ray detectors which are difficult to eliminate. The usage of radiation protection measures still needs to be improved. ► Responsible use of digital intraoral radiology results in a significant dose reduction in everyday practice. ► The ALARA principle is only achieved by strict implementation of dose-reducing methods. ► The efforts to use dose-reducing devices must be increased. © Georg Thieme Verlag KG Stuttgart · New York.
2010-06-01
CCD Astrograph Catalog (UCAC3). For these new reductions we used over 216,000 CCD exposures. The Two-Micron All-Sky Survey ( 2MASS ) data are used...distortions and sub-pixel phase errors have also been evaluated using the residuals with respect to 2MASS . The overall magnitude equation is derived from...Høg et al. 2000) reference frame as in UCAC2. However, Two-Micron All Sky Survey ( 2MASS ; Skrutskie et al. 2006) residuals are used to probe for
Optical readout of a two phase liquid argon TPC using CCD camera and THGEMs
NASA Astrophysics Data System (ADS)
Mavrokoridis, K.; Ball, F.; Carroll, J.; Lazos, M.; McCormick, K. J.; Smith, N. A.; Touramanis, C.; Walker, J.
2014-02-01
This paper presents a preliminary study into the use of CCDs to image secondary scintillation light generated by THick Gas Electron Multipliers (THGEMs) in a two phase LAr TPC. A Sony ICX285AL CCD chip was mounted above a double THGEM in the gas phase of a 40 litre two-phase LAr TPC with the majority of the camera electronics positioned externally via a feedthrough. An Am-241 source was mounted on a rotatable motion feedthrough allowing the positioning of the alpha source either inside or outside of the field cage. Developed for and incorporated into the TPC design was a novel high voltage feedthrough featuring LAr insulation. Furthermore, a range of webcams were tested for operation in cryogenics as an internal detector monitoring tool. Of the range of webcams tested the Microsoft HD-3000 (model no:1456) webcam was found to be superior in terms of noise and lowest operating temperature. In ambient temperature and atmospheric pressure 1 ppm pure argon gas, the THGEM gain was ≈ 1000 and using a 1 msec exposure the CCD captured single alpha tracks. Successful operation of the CCD camera in two-phase cryogenic mode was also achieved. Using a 10 sec exposure a photograph of secondary scintillation light induced by the Am-241 source in LAr has been captured for the first time.
Smear correction of highly variable, frame-transfer CCD images with application to polarimetry.
Iglesias, Francisco A; Feller, Alex; Nagaraju, Krishnappa
2015-07-01
Image smear, produced by the shutterless operation of frame-transfer CCD detectors, can be detrimental for many imaging applications. Existing algorithms used to numerically remove smear do not contemplate cases where intensity levels change considerably between consecutive frame exposures. In this report, we reformulate the smearing model to include specific variations of the sensor illumination. The corresponding desmearing expression and its noise properties are also presented and demonstrated in the context of fast imaging polarimetry.
Changes in transcript abundance relating to colony collapse disorder in honey bees (Apis mellifera).
Johnson, Reed M; Evans, Jay D; Robinson, Gene E; Berenbaum, May R
2009-09-01
Colony collapse disorder (CCD) is a mysterious disappearance of honey bees that has beset beekeepers in the United States since late 2006. Pathogens and other environmental stresses, including pesticides, have been linked to CCD, but a causal relationship has not yet been demonstrated. Because the gut acts as a primary interface between the honey bee and its environment as a site of entry for pathogens and toxins, we used whole-genome microarrays to compare gene expression between guts of bees from CCD colonies originating on both the east and west coasts of the United States and guts of bees from healthy colonies sampled before the emergence of CCD. Considerable variation in gene expression was associated with the geographical origin of bees, but a consensus list of 65 transcripts was identified as potential markers for CCD status. Overall, elevated expression of pesticide response genes was not observed. Genes involved in immune response showed no clear trend in expression pattern despite the increased prevalence of viruses and other pathogens in CCD colonies. Microarray analysis revealed unusual ribosomal RNA fragments that were conspicuously more abundant in the guts of CCD bees. The presence of these fragments may be a possible consequence of picorna-like viral infection, including deformed wing virus and Israeli acute paralysis virus, and may be related to arrested translation. Ribosomal fragment abundance and presence of multiple viruses may prove to be useful diagnostic markers for colonies afflicted with CCD.
Changes in transcript abundance relating to colony collapse disorder in honey bees (Apis mellifera)
Johnson, Reed M.; Evans, Jay D.; Robinson, Gene E.; Berenbaum, May R.
2009-01-01
Colony collapse disorder (CCD) is a mysterious disappearance of honey bees that has beset beekeepers in the United States since late 2006. Pathogens and other environmental stresses, including pesticides, have been linked to CCD, but a causal relationship has not yet been demonstrated. Because the gut acts as a primary interface between the honey bee and its environment as a site of entry for pathogens and toxins, we used whole-genome microarrays to compare gene expression between guts of bees from CCD colonies originating on both the east and west coasts of the United States and guts of bees from healthy colonies sampled before the emergence of CCD. Considerable variation in gene expression was associated with the geographical origin of bees, but a consensus list of 65 transcripts was identified as potential markers for CCD status. Overall, elevated expression of pesticide response genes was not observed. Genes involved in immune response showed no clear trend in expression pattern despite the increased prevalence of viruses and other pathogens in CCD colonies. Microarray analysis revealed unusual ribosomal RNA fragments that were conspicuously more abundant in the guts of CCD bees. The presence of these fragments may be a possible consequence of picorna-like viral infection, including deformed wing virus and Israeli acute paralysis virus, and may be related to arrested translation. Ribosomal fragment abundance and presence of multiple viruses may prove to be useful diagnostic markers for colonies afflicted with CCD. PMID:19706391
CCD Camera Lens Interface for Real-Time Theodolite Alignment
NASA Technical Reports Server (NTRS)
Wake, Shane; Scott, V. Stanley, III
2012-01-01
Theodolites are a common instrument in the testing, alignment, and building of various systems ranging from a single optical component to an entire instrument. They provide a precise way to measure horizontal and vertical angles. They can be used to align multiple objects in a desired way at specific angles. They can also be used to reference a specific location or orientation of an object that has moved. Some systems may require a small margin of error in position of components. A theodolite can assist with accurately measuring and/or minimizing that error. The technology is an adapter for a CCD camera with lens to attach to a Leica Wild T3000 Theodolite eyepiece that enables viewing on a connected monitor, and thus can be utilized with multiple theodolites simultaneously. This technology removes a substantial part of human error by relying on the CCD camera and monitors. It also allows image recording of the alignment, and therefore provides a quantitative means to measure such error.
Double Star Measurements at the Southern Sky with 50 cm Reflectors and Fast CCD Cameras in 2012
NASA Astrophysics Data System (ADS)
Anton, Rainer
2014-07-01
A Cassegrain and a Ritchey-Chrétien reflector, both with 50 cm aperture, were used in Namibia for recordings of double stars with fast CCD cameras and a notebook computer. From superposition of "lucky images", measurements of 39 double and multiple systems were obtained and compared with literature data. Occasional deviations are discussed. Images of some remarkable systems are also presented.
Evaluation of tellurium toxicity in transformed and non-transformed human colon cells.
Vij, Puneet; Hardej, Diane
2012-11-01
Diphenyl ditelluride (DPDT) and tellurium tetrachloride (TeCl(4)) were evaluated for toxicity in transformed (HT-29, Caco-2) and non-transformed colon cells (CCD-18Co). Significant decreases in viability were observed with DPDT exposure in HT-29 (62.5-1000 μM), Caco-2 (31.25-1000 μM) and CCD-18Co cells (500-1000 μM) and with TeCl(4) in HT-29 (31.25-1000 μM), Caco-2 (31.25-1000 μM) and CCD-18Co cells (500-1000 μM). Light microscopy confirmed viability analysis. Significant increases in caspase 3/7 and 9 activity were observed with DPDT in HT-29 (500-1000 μM) and CCD-18Co cells (1000 μM) indicating apoptosis. No significant increases in caspases were seen with TeCl(4) indicating necrosis. Apoptosis or necrosis was confirmed with fluorescent staining (FITC-Annexin, Hoechst 33342 and Ethidium Homodimer). Significant decreases in GSH/GSSG ratio were observed with DPDT in HT-29 (62.5-1000 μM), and CCD-18Co cells (1000 μM) and with TeCl(4) in HT-29 (62.5-1000 μM) and CCD-18Co cells (250-1000 μM). We concluded that cells treated with DPDT resulted in apoptosis and TeCl(4) treatment in necrosis. GSH/GSSG ratio shifts indicate oxidative mechanisms are involved. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Chatterjee, Abhijit; Verma, Anurag
2016-05-01
The Advanced Wide Field Sensor (AWiFS) camera caters to high temporal resolution requirement of Resourcesat-2A mission with repeativity of 5 days. The AWiFS camera consists of four spectral bands, three in the visible and near IR and one in the short wave infrared. The imaging concept in VNIR bands is based on push broom scanning that uses linear array silicon charge coupled device (CCD) based Focal Plane Array (FPA). On-Board Calibration unit for these CCD based FPAs is used to monitor any degradation in FPA during entire mission life. Four LEDs are operated in constant current mode and 16 different light intensity levels are generated by electronically changing exposure of CCD throughout the calibration cycle. This paper describes experimental setup and characterization results of various flight model visible LEDs (λP=650nm) for development of On-Board Calibration unit of Advanced Wide Field Sensor (AWiFS) camera of RESOURCESAT-2A. Various LED configurations have been studied to meet dynamic range coverage of 6000 pixels silicon CCD based focal plane array from 20% to 60% of saturation during night pass of the satellite to identify degradation of detector elements. The paper also explains comparison of simulation and experimental results of CCD output profile at different LED combinations in constant current mode.
NASA Technical Reports Server (NTRS)
1994-01-01
Charge Coupled Devices (CCDs) are high technology silicon chips that connect light directly into electronic or digital images, which can be manipulated or enhanced by computers. When Goddard Space Flight Center (GSFC) scientists realized that existing CCD technology could not meet scientific requirements for the Hubble Space Telescope Imagining Spectrograph, GSFC contracted with Scientific Imaging Technologies, Inc. (SITe) to develop an advanced CCD. SITe then applied many of the NASA-driven enhancements to the manufacture of CCDs for digital mammography. The resulting device images breast tissue more clearly and efficiently. The LORAD Stereo Guide Breast Biopsy system incorporates SITe's CCD as part of a digital camera system that is replacing surgical biopsy in many cases. Known as stereotactic needle biopsy, it is performed under local anesthesia with a needle and saves women time, pain, scarring, radiation exposure and money.
Colony Collapse Disorder (CCD) and bee age impact honey bee pathophysiology
Traynor, Kirsten S.; Andree, Michael; Lichtenberg, Elinor M.; Chen, Yanping; Saegerman, Claude; Cox-Foster, Diana L.
2017-01-01
Honey bee (Apis mellifera) colonies continue to experience high annual losses that remain poorly explained. Numerous interacting factors have been linked to colony declines. Understanding the pathways linking pathophysiology with symptoms is an important step in understanding the mechanisms of disease. In this study we examined the specific pathologies associated with honey bees collected from colonies suffering from Colony Collapse Disorder (CCD) and compared these with bees collected from apparently healthy colonies. We identified a set of pathological physical characteristics that occurred at different rates in CCD diagnosed colonies prior to their collapse: rectum distension, Malpighian tubule iridescence, fecal matter consistency, rectal enteroliths (hard concretions), and venom sac color. The multiple differences in rectum symptomology in bees from CCD apiaries and colonies suggest effected bees had trouble regulating water. To ensure that pathologies we found associated with CCD were indeed pathologies and not due to normal changes in physical appearances that occur as an adult bee ages (CCD colonies are assumed to be composed mostly of young bees), we documented the changes in bees of different ages taken from healthy colonies. We found that young bees had much greater incidences of white nodules than older cohorts. Prevalent in newly-emerged bees, these white nodules or cellular encapsulations indicate an active immune response. Comparing the two sets of characteristics, we determined a subset of pathologies that reliably predict CCD status rather than bee age (fecal matter consistency, rectal distension size, rectal enteroliths and Malpighian tubule iridescence) and that may serve as biomarkers for colony health. In addition, these pathologies suggest that CCD bees are experiencing disrupted excretory physiology. Our identification of these symptoms is an important first step in understanding the physiological pathways that underlie CCD and factors impacting bee health. PMID:28715431
Colony Collapse Disorder (CCD) and bee age impact honey bee pathophysiology.
vanEngelsdorp, Dennis; Traynor, Kirsten S; Andree, Michael; Lichtenberg, Elinor M; Chen, Yanping; Saegerman, Claude; Cox-Foster, Diana L
2017-01-01
Honey bee (Apis mellifera) colonies continue to experience high annual losses that remain poorly explained. Numerous interacting factors have been linked to colony declines. Understanding the pathways linking pathophysiology with symptoms is an important step in understanding the mechanisms of disease. In this study we examined the specific pathologies associated with honey bees collected from colonies suffering from Colony Collapse Disorder (CCD) and compared these with bees collected from apparently healthy colonies. We identified a set of pathological physical characteristics that occurred at different rates in CCD diagnosed colonies prior to their collapse: rectum distension, Malpighian tubule iridescence, fecal matter consistency, rectal enteroliths (hard concretions), and venom sac color. The multiple differences in rectum symptomology in bees from CCD apiaries and colonies suggest effected bees had trouble regulating water. To ensure that pathologies we found associated with CCD were indeed pathologies and not due to normal changes in physical appearances that occur as an adult bee ages (CCD colonies are assumed to be composed mostly of young bees), we documented the changes in bees of different ages taken from healthy colonies. We found that young bees had much greater incidences of white nodules than older cohorts. Prevalent in newly-emerged bees, these white nodules or cellular encapsulations indicate an active immune response. Comparing the two sets of characteristics, we determined a subset of pathologies that reliably predict CCD status rather than bee age (fecal matter consistency, rectal distension size, rectal enteroliths and Malpighian tubule iridescence) and that may serve as biomarkers for colony health. In addition, these pathologies suggest that CCD bees are experiencing disrupted excretory physiology. Our identification of these symptoms is an important first step in understanding the physiological pathways that underlie CCD and factors impacting bee health.
CCD image sensor induced error in PIV applications
NASA Astrophysics Data System (ADS)
Legrand, M.; Nogueira, J.; Vargas, A. A.; Ventas, R.; Rodríguez-Hidalgo, M. C.
2014-06-01
The readout procedure of charge-coupled device (CCD) cameras is known to generate some image degradation in different scientific imaging fields, especially in astrophysics. In the particular field of particle image velocimetry (PIV), widely extended in the scientific community, the readout procedure of the interline CCD sensor induces a bias in the registered position of particle images. This work proposes simple procedures to predict the magnitude of the associated measurement error. Generally, there are differences in the position bias for the different images of a certain particle at each PIV frame. This leads to a substantial bias error in the PIV velocity measurement (˜0.1 pixels). This is the order of magnitude that other typical PIV errors such as peak-locking may reach. Based on modern CCD technology and architecture, this work offers a description of the readout phenomenon and proposes a modeling for the CCD readout bias error magnitude. This bias, in turn, generates a velocity measurement bias error when there is an illumination difference between two successive PIV exposures. The model predictions match the experiments performed with two 12-bit-depth interline CCD cameras (MegaPlus ES 4.0/E incorporating the Kodak KAI-4000M CCD sensor with 4 megapixels). For different cameras, only two constant values are needed to fit the proposed calibration model and predict the error from the readout procedure. Tests by different researchers using different cameras would allow verification of the model, that can be used to optimize acquisition setups. Simple procedures to obtain these two calibration values are also described.
NASA Astrophysics Data System (ADS)
Fischer, P.
1997-12-01
Weak distortions of background galaxies are rapidly emerging as a powerful tool for the measurement of galaxy cluster mass distributions. Lensing based studies have the advantage of being direct measurements of mass and are not model-dependent as are other techniques (X-ray, radial velocities). To date studies have been limited by CCD field size meaning that full coverage of the clusters out to the virial radii and beyond has not been possible. Probing this large radius region is essential for testing models of large scale structure formation. New wide field CCD mosaics, for the first time, allow mass measurements out to very large radius. We have obtained images for a sample of clusters with the ``Big Throughput Camera'' (BTC) on the CTIO 4m. This camera comprises four thinned SITE 2048(2) CCDs, each 15arcmin on a side for a total area of one quarter of a square degree. We have developed an automated reduction pipeline which: 1) corrects for spatial distortions, 2) corrects for PSF anisotropy, 3) determines relative scaling and background levels, and 4) combines multiple exposures. In this poster we will present some preliminary results of our cluster lensing study. This will include radial mass and light profiles and 2-d mass and galaxy density maps.
Double Star Measurements at the Southern Sky with a 50 cm Reflector and a Fast CCD Camera in 2014
NASA Astrophysics Data System (ADS)
Anton, Rainer
2015-04-01
A Ritchey-Chrétien reflector with 50 cm aperture was used in Namibia for recordings of double stars with a fast CCD camera and a notebook computer. From superposition of "lucky images", measurements of 91 pairings in 79 double and multiple systems were obtained and compared with literature data. Occasional deviations are discussed. Some images of noteworthy systems are also presented.
VizieR Online Data Catalog: LY And photometric followup (Lu+, 2017)
NASA Astrophysics Data System (ADS)
Lu, H.-P.; Zhang, L.-Y.; Han, X. L.; Pi, Q.-F.; Wang, D.-M.
2017-04-01
We obtained our first photometric data set in R and I bands for LY And on November 24, 2014 using the 1-m RCC reflecting telescope at Yunnan Observatory, which was equipped with an Andor DW436 2048x2048 CCD camera with a field of view of 7.3'x7.3'. The exposure times were 300s for both R and I bands. We obtained our second photometric data set in B, V, R and I bands using the SARA 914-mm telescope at Kitt Peak National Observatory on October 23, 2015. This telescope was equipped with a 2048x2048 pixels CCD and each pixel after 2x2 binning is about 0.86". The exposure times were 120s in B band and 60 s in V, R and I bands, respectively. (3 data files).
Environmental performance evaluation of an advanced-design solid-state television camera
NASA Technical Reports Server (NTRS)
1979-01-01
The development of an advanced-design black-and-white solid-state television camera which can survive exposure to space environmental conditions was undertaken. A 380 x 488 element buried-channel CCD is utilized as the image sensor to ensure compatibility with 525-line transmission and display equipment. Specific camera design approaches selected for study and analysis included: (1) component and circuit sensitivity to temperature; (2) circuit board thermal and mechanical design; and (3) CCD temperature control. Preferred approaches were determined and integrated into the final design for two deliverable solid-state TV cameras. One of these cameras was subjected to environmental tests to determine stress limits for exposure to vibration, shock, acceleration, and temperature-vacuum conditions. These tests indicate performance at the design goal limits can be achieved for most of the specified conditions.
The CTIO Acquisition CCD-TV camera design
NASA Astrophysics Data System (ADS)
Schmidt, Ricardo E.
1990-07-01
A CCD-based Acquisition TV Camera has been developed at CTIO to replace the existing ISIT units. In a 60 second exposure, the new Camera shows a sixfold improvement in sensitivity over an ISIT used with a Leaky Memory. Integration times can be varied over a 0.5 to 64 second range. The CCD, contained in an evacuated enclosure, is operated at -45 C. Only the image section, an area of 8.5 mm x 6.4 mm, gets exposed to light. Pixel size is 22 microns and either no binning or 2 x 2 binning can be selected. The typical readout rates used vary between 3.5 and 9 microseconds/pixel. Images are stored in a PC/XT/AT, which generates RS-170 video. The contrast in the RS-170 frames is automatically enhanced by the software.
Comparing the TYCHO Catalogue with CCD Astrograph Observations
NASA Astrophysics Data System (ADS)
Zacharias, N.; Hoeg, E.; Urban, S. E.; Corbin, T. E.
1997-08-01
Selected fields around radio-optical reference frame sources have been observed with the U.S. Naval Observatory CCD astrograph (UCA). This telescope is equipped with a red-corrected 206mm 5-element lens and a 4k by 4k CCD camera which provides a 1 square degree field of view. Positions with internal precisions of 20 mas for stars in the 7 to 12 magnitude range have been obtained with 30 second exposures. A comparison is made with the Tycho Catalogue, which is accurate to about 5 to 50 mas at mean epoch of J1991.25, depending on the magnitude of the star. Preliminary proper motions are obtained using the Astrographic Catalogue (AC) to update the Tycho positions to the epoch of the UCA observations, which adds an error contribution of about 15 to 20 mas. Individual CCD frames have been reduced with an average of 30 Tycho reference stars per frame. A linear plate model gives an average adjustment standard error of 46 mas, consistent with the internal errors. The UCA is capable of significantly improving the positions of Tycho stars fainter than about visual magnitude 9.5.
The superiority of L3-CCDs in the high-flux and wide dynamic range regimes
NASA Astrophysics Data System (ADS)
Butler, Raymond F.; Sheehan, Brendan J.
2008-02-01
Low Light Level CCD (L3-CCD) cameras have received much attention for high cadence astronomical imaging applications. Efforts to date have concentrated on exploiting them for two scenarios: post-exposure image sharpening and ``lucky imaging'', and rapid variability in astrophysically interesting sources. We demonstrate their marked superiority in a third distinct scenario: observing in the high-flux and wide dynamic range regimes. We realized that the unique features of L3-CCDs would make them ideal for maximizing signal-to-noise in observations of bright objects (whether variable or not), and for high dynamic range scenarios such as faint targets embedded in a crowded field of bright objects. Conventional CCDs have drawbacks in such regimes, due to a poor duty cycle-the combination of short exposure times (for time-series sampling or to avoid saturation) and extended readout times (for minimizing readout noise). For different telescope sizes, we use detailed models to show that a range of conventional imaging systems are photometrically out-performed across a wide range of object brightness, once the operational parameters of the L3-CCD are carefully set. The cross-over fluxes, above which the L3-CCD is operationally superior, are surprisingly faint-even for modest telescope apertures. We also show that the use of L3-CCDs is the optimum strategy for minimizing atmospheric scintillation noise in photometric observations employing a given telescope aperture. This is particularly significant, since scintillation can be the largest source of error in timeseries photometry. These results should prompt a new direction in developing imaging instrumentation solutions for observatories.
Brown, Sarah; Hinsley, Samantha; Ballesteros, Mónica; Bourne, Sue; McGarry, Paul; Sherratt, Debbie; Flanagan, Louise; Gregory, Walter; Cavenagh, Jamie; Owen, Roger; Williams, Cathy; Kaiser, Martin; Low, Eric; Yong, Kwee
2016-01-01
Multiple myeloma is a plasma cell tumour with an annual incidence in the UK of approximately 40-50 per million i.e. about 4500 new cases per annum. The triple combination cyclophosphamide, bortezomib (Velcade®) and dexamethasone (CVD) is an effective regimen at relapse and has emerged in recent years as the standard therapy at first relapse in the UK. Carfilzomib has good activity as a single agent in the relapsed setting, and it is expected that efficacy will be improved when used in combination with dexamethasone and cyclophosphamide. MUK Five is a phase II open label, randomised, controlled, parallel group, multi-centre trial that will compare the activity of carfilzomib, cyclophosphamide and dexamethasone (CCD) with that of CVD, given over an equivalent treatment period (24 weeks), in participants with multiple myeloma at first relapse, or refractory to no more than 1 line of treatment. In addition, the study also aims to assess the utility of a maintenance schedule of carfilzomib in these participants. The primary objective of the trial is to assess whether CCD provides non-inferior activity in terms of ≥ VGPR rates at 24 weeks, and whether the addition of maintenance treatment with carfilzomib to CCD provides superior activity in terms of progression-free survival, as compared to CCD with no maintenance. Secondary objectives include comparing toxicity profiles, further summarizing and comparing the activity of the different treatment arms and analysis of the effect of each treatment arm on minimal residual disease status. The development of carfilzomib offers the opportunity to further explore the anti-tumour efficacy of proteasome inhibition and, based on the available evidence, it is important and timely to obtain data on the activity, toxicity and tolerability of this drug. In contrast to ongoing phase III trials, this phase II trial has a unique subset of participants diagnosed with multiple myeloma at first relapse or refractory to no more than 1 line of treatment and will also evaluate the utility of maintenance with carfilzomib for up to 18 months and investigate minimal residual disease status to provide information on depth of response and the prognostic impact thereof. The trial is registered under ISRCTN17354232, December 2012.
Principal components analysis of the photoresponse nonuniformity of a matrix detector.
Ferrero, Alejandro; Alda, Javier; Campos, Joaquín; López-Alonso, Jose Manuel; Pons, Alicia
2007-01-01
The principal component analysis is used to identify and quantify spatial distributions of relative photoresponse as a function of the exposure time for a visible CCD array. The analysis shows a simple way to define an invariant photoresponse nonuniformity and compare it with the definition of this invariant pattern as the one obtained for long exposure times. Experimental data of radiant exposure from levels of irradiance obtained in a stable and well-controlled environment are used.
Fujimura, Kei E; Demoor, Tine; Rauch, Marcus; Faruqi, Ali A; Jang, Sihyug; Johnson, Christine C; Boushey, Homer A; Zoratti, Edward; Ownby, Dennis; Lukacs, Nicholas W; Lynch, Susan V
2014-01-14
Exposure to dogs in early infancy has been shown to reduce the risk of childhood allergic disease development, and dog ownership is associated with a distinct house dust microbial exposure. Here, we demonstrate, using murine models, that exposure of mice to dog-associated house dust protects against ovalbumin or cockroach allergen-mediated airway pathology. Protected animals exhibited significant reduction in the total number of airway T cells, down-regulation of Th2-related airway responses, as well as mucin secretion. Following dog-associated dust exposure, the cecal microbiome of protected animals was extensively restructured with significant enrichment of, amongst others, Lactobacillus johnsonii. Supplementation of wild-type animals with L. johnsonii protected them against both airway allergen challenge or infection with respiratory syncytial virus. L. johnsonii-mediated protection was associated with significant reductions in the total number and proportion of activated CD11c(+)/CD11b(+) and CD11c(+)/CD8(+) cells, as well as significantly reduced airway Th2 cytokine expression. Our results reveal that exposure to dog-associated household dust results in protection against airway allergen challenge and a distinct gastrointestinal microbiome composition. Moreover, the study identifies L. johnsonii as a pivotal species within the gastrointestinal tract capable of influencing adaptive immunity at remote mucosal surfaces in a manner that is protective against a variety of respiratory insults.
Fujimura, Kei E.; Demoor, Tine; Rauch, Marcus; Faruqi, Ali A.; Jang, Sihyug; Johnson, Christine C.; Boushey, Homer A.; Zoratti, Edward; Ownby, Dennis; Lukacs, Nicholas W.; Lynch, Susan V.
2014-01-01
Exposure to dogs in early infancy has been shown to reduce the risk of childhood allergic disease development, and dog ownership is associated with a distinct house dust microbial exposure. Here, we demonstrate, using murine models, that exposure of mice to dog-associated house dust protects against ovalbumin or cockroach allergen-mediated airway pathology. Protected animals exhibited significant reduction in the total number of airway T cells, down-regulation of Th2-related airway responses, as well as mucin secretion. Following dog-associated dust exposure, the cecal microbiome of protected animals was extensively restructured with significant enrichment of, amongst others, Lactobacillus johnsonii. Supplementation of wild-type animals with L. johnsonii protected them against both airway allergen challenge or infection with respiratory syncytial virus. L. johnsonii-mediated protection was associated with significant reductions in the total number and proportion of activated CD11c+/CD11b+ and CD11c+/CD8+ cells, as well as significantly reduced airway Th2 cytokine expression. Our results reveal that exposure to dog-associated household dust results in protection against airway allergen challenge and a distinct gastrointestinal microbiome composition. Moreover, the study identifies L. johnsonii as a pivotal species within the gastrointestinal tract capable of influencing adaptive immunity at remote mucosal surfaces in a manner that is protective against a variety of respiratory insults. PMID:24344318
The development of large-aperture test system of infrared camera and visible CCD camera
NASA Astrophysics Data System (ADS)
Li, Yingwen; Geng, Anbing; Wang, Bo; Wang, Haitao; Wu, Yanying
2015-10-01
Infrared camera and CCD camera dual-band imaging system is used in many equipment and application widely. If it is tested using the traditional infrared camera test system and visible CCD test system, 2 times of installation and alignment are needed in the test procedure. The large-aperture test system of infrared camera and visible CCD camera uses the common large-aperture reflection collimator, target wheel, frame-grabber, computer which reduces the cost and the time of installation and alignment. Multiple-frame averaging algorithm is used to reduce the influence of random noise. Athermal optical design is adopted to reduce the change of focal length location change of collimator when the environmental temperature is changing, and the image quality of the collimator of large field of view and test accuracy are also improved. Its performance is the same as that of the exotic congener and is much cheaper. It will have a good market.
3D digital image correlation using single color camera pseudo-stereo system
NASA Astrophysics Data System (ADS)
Li, Junrui; Dan, Xizuo; Xu, Wan; Wang, Yonghong; Yang, Guobiao; Yang, Lianxiang
2017-10-01
Three dimensional digital image correlation (3D-DIC) has been widely used by industry to measure the 3D contour and whole-field displacement/strain. In this paper, a novel single color camera 3D-DIC setup, using a reflection-based pseudo-stereo system, is proposed. Compared to the conventional single camera pseudo-stereo system, which splits the CCD sensor into two halves to capture the stereo views, the proposed system achieves both views using the whole CCD chip and without reducing the spatial resolution. In addition, similarly to the conventional 3D-DIC system, the center of the two views stands in the center of the CCD chip, which minimizes the image distortion relative to the conventional pseudo-stereo system. The two overlapped views in the CCD are separated by the color domain, and the standard 3D-DIC algorithm can be utilized directly to perform the evaluation. The system's principle and experimental setup are described in detail, and multiple tests are performed to validate the system.
Miyoshi, Hirokazu; Hiroura, Mitsunori; Tsujimoto, Kazunori; Irikura, Namiko; Otani, Tamaki; Shinohara, Yasuo
2017-05-01
A new scintillation imaging material [scintillator-silica fine powder (FP)] was prepared using silica FPs and scintillator-encapsulating silica nanoparticles (NPs) (scintillator-silica NPs). The wt% values of scintillator-silica NPs on the scintillator-silica FPs were 38, 43, 36 and 44%. Scintillation images of 3H, 63Ni, 35S, 33P, 204Tl, 89Sr and 32P dropped on the scintillator-silica FPs were obtained at about 37 kBq per 0.1-10 µl with a charge-coupled device (CCD) imager for a 5 min exposure. In particular, high-intensity CCD images of 35S were selectively obtained using the 2.25, 4.77 and 10 µm silica FPs with scintillator-silica NPs owing to the residual S of dimethyl sulfoxide in the preparation. Scintillation images of 3H at 1670 ± 9 Bq/0.5 µl and 347 ± 6 Bq/0.5 µl dropped in a 2 mm hole on the scintillator-silica FPs (6.78 and 10 µm) were also obtained using the CCD imager for a 2 h exposure. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
High-speed line-scan camera with digital time delay integration
NASA Astrophysics Data System (ADS)
Bodenstorfer, Ernst; Fürtler, Johannes; Brodersen, Jörg; Mayer, Konrad J.; Eckel, Christian; Gravogl, Klaus; Nachtnebel, Herbert
2007-02-01
Dealing with high-speed image acquisition and processing systems, the speed of operation is often limited by the amount of available light, due to short exposure times. Therefore, high-speed applications often use line-scan cameras, based on charge-coupled device (CCD) sensors with time delayed integration (TDI). Synchronous shift and accumulation of photoelectric charges on the CCD chip - according to the objects' movement - result in a longer effective exposure time without introducing additional motion blur. This paper presents a high-speed color line-scan camera based on a commercial complementary metal oxide semiconductor (CMOS) area image sensor with a Bayer filter matrix and a field programmable gate array (FPGA). The camera implements a digital equivalent to the TDI effect exploited with CCD cameras. The proposed design benefits from the high frame rates of CMOS sensors and from the possibility of arbitrarily addressing the rows of the sensor's pixel array. For the digital TDI just a small number of rows are read out from the area sensor which are then shifted and accumulated according to the movement of the inspected objects. This paper gives a detailed description of the digital TDI algorithm implemented on the FPGA. Relevant aspects for the practical application are discussed and key features of the camera are listed.
An Investigation into the Spectral Imaging of Hall Thruster Plumes
2015-07-01
imaging experiment. It employs a Kodak KAF-3200E 3 megapixel CCD (2184×1472 with 6.8 µm pixels). The camera was designed for astronomical imaging and thus...19 mml 14c--7_0_m_m_~•... ,. ,. 50 mm I· ·I ,. 41 mm I Kodak KAF- 3200E ceo 2184 x 1472 px 14.9 x 10.0 mm 6.8 x 6.8J..Lm pixel size SBIG ST...It employs a Kodak KAF-3200E 3 megapixel CCD (2184×1472 with 6.8 µm pixels). The camera was designed for astronomical imaging and thus long exposure
VizieR Online Data Catalog: Proper motions and photometry of stars in NGC 3201 (Sariya+, 2017)
NASA Astrophysics Data System (ADS)
Sariya, D. P.; Jiang, I.-G.; Yadav, R. K. S.
2017-07-01
To determine the PMs of the stars in this work, we used archive images (http://archive.eso.org/eso/esoarchivemain.html) from observations made with the 2.2m ESO/MPI telescope at La Silla, Chile. This telescope contains a mosaic camera called the Wide-Field Imager (WFI), consisting of 4*2 (i.e., 8 CCD chips). Since each CCD has an array of 2048*4096 pixels, WFI ultimately produces images with a 34*33arcmin2 field of view. The observational run of the first epoch contains two images in B,V and I bands, each with 240s exposure time observed on 1999 December 05. In the second epoch, we have 35 images with 40s exposure time each in V filter observed during the period of 2014 April 02-05. Thus the epoch gap between the data is ~14.3 years. (2 data files).
DQE analysis for CCD imaging arrays
NASA Astrophysics Data System (ADS)
Shaw, Rodney
1997-05-01
By consideration of the statistical interaction between exposure quanta and the mechanisms of image detection, the signal-to-noise limitations of a variety of image acquisition technologies are now well understood. However in spite of the growing fields of application for CCD imaging- arrays and the obvious advantages of their multi-level mode of quantum detection, only limited and largely empirical approaches have been made to quantify these advantages on an absolute basis. Here an extension is made of a previous model for noise-free sequential photon-counting to the more general case involving both count-noise and arbitrary separation functions between count levels. This allows a basic model to be developed for the DQE associated with devices which approximate to the CCD mode of operation, and conclusions to be made concerning the roles of the separation-function and count-noise in defining the departure from the ideal photon counter.
NASA Astrophysics Data System (ADS)
Bessell, Michael S.
2000-08-01
Spectacular colour images have been made by combining CCD images in three different passbands using Adobe Photoshop. These beautiful images highlight a variety of astrophysical phenomena and should be a valuable resource for science education and public awareness of science. The wide field images were obtained at the Siding Spring Observatory (SSO) by mounting a Hasselblad or Nikkor telephoto lens in front of a 2K × 2K CCD. Options of more than 30 degrees or 6 degrees square coverage are produced in a single exposure in this way. Narrow band or broad band filters were placed between lens and CCD enabling deep, linear images in a variety of passbands to be obtained. We have mapped the LMC and SMC and are mapping the Galactic Plane for comparison with the Molonglo Radio Survey. Higher resolution images have also been made with the 40 inch telescope of galaxies and star forming regions in the Milky Way.
Solar x ray astronomy rocket program
NASA Technical Reports Server (NTRS)
1990-01-01
The dynamics were studied of the solar corona through the imaging of large scale coronal structures with AS&E High Resolution Soft X ray Imaging Solar Sounding Rocket Payload. The proposal for this program outlined a plan of research based on the construction of a high sensitivity X ray telescope from the optical and electronic components of the previous flight of this payload (36.038CS). Specifically, the X ray sensitive CCD camera was to be placed in the prime focus of the grazing incidence X ray mirror. The improved quantum efficiency of the CCD detector (over the film which had previously been used) allows quantitative measurements of temperature and emission measure in regions of low x ray emission such as helmet streamers beyond 1.2 solar radii or coronal holes. Furthermore, the improved sensitivity of the CCD allows short exposures of bright objects to study unexplored temporal regimes of active region loop evolution.
Inexpensive Neutron Imaging Cameras Using CCDs for Astronomy
NASA Astrophysics Data System (ADS)
Hewat, A. W.
We have developed inexpensive neutron imaging cameras using CCDs originally designed for amateur astronomical observation. The low-light, high resolution requirements of such CCDs are similar to those for neutron imaging, except that noise as well as cost is reduced by using slower read-out electronics. For example, we use the same 2048x2048 pixel ;Kodak; KAI-4022 CCD as used in the high performance PCO-2000 CCD camera, but our electronics requires ∼5 sec for full-frame read-out, ten times slower than the PCO-2000. Since neutron exposures also require several seconds, this is not seen as a serious disadvantage for many applications. If higher frame rates are needed, the CCD unit on our camera can be easily swapped for a faster readout detector with similar chip size and resolution, such as the PCO-2000 or the sCMOS PCO.edge 4.2.
Kawakami, Hiroshi; Ogimoto, Akiyoshi; Tokunaga, Naohito; Nishimura, Kazuhisa; Kawakami, Hideo; Higashi, Haruhiko; Iio, Chiharuko; Kono, Tamami; Aono, Jun; Uetani, Teruyoshi; Nagai, Takayuki; Inoue, Katsuji; Suzuki, Jun; Ikeda, Shuntaro; Okura, Takafumi; Ohyagi, Yasumasa; Tabara, Yasuharu; Higaki, Jitsuo
2018-05-30
The cardiac phenotype of laminopathies is characterized by cardiac conduction disorders (CCDs) and dilated cardiomyopathy (DCM). Although laminopathies have been considered monogenic, they exhibit a remarkable degree of clinical variability. This case series aimed to detect the causal mutation and to investigate the causes of clinical variability in a Japanese family with inherited CCD and DCM.Of the five family members investigated, four had either CCD/DCM or CCD alone, while one subject had no cardiovascular disease and acted as a normal control. We performed targeted resequencing of 174 inherited cardiovascular disease-associated genes in this family and pathological mutations were confirmed using Sanger sequencing. The degree of clinical severity and variability were also evaluated using long-term medical records. We discovered a novel heterozygous truncating lamin A/C (LMNA) mutation (c.774delG) in all four subjects with CCD. Because this mutation was predicted to cause a frameshift mutation and premature termination (p.Gln258HisfsTer222) in LMNA, we believe that this LMNA mutation was the causal mutation in this family with CCD and laminopathies. In addition, gender-specific intra-familiar clinical variability was observed in this Japanese family where affected males exhibited an earlier onset of CCD and more severe DCM compared to affected females. Using targeted resequencing, we discovered a novel truncating LMNA mutation associated with CCD and DCM in this family characterized by gender differences in clinical severity in LMNA carriers. Our results suggest that in patients with laminopathy, clinical severity may be the result of multiple factors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taneja, S; Fru, L Che; Desai, V
Purpose: It is now commonplace to handle treatments of hyperthyroidism using iodine-131 as an outpatient procedure due to lower costs and less stringent federal regulations. The Nuclear Regulatory Commission has currently updated release guidelines for these procedures, but there is still a large uncertainty in the dose to the public. Current guidelines to minimize dose to the public require patients to remain isolated after treatment. The purpose of this study was to use a low-cost common device, such as a cell phone, to estimate exposure emitted from a patient to the general public. Methods: Measurements were performed using an Applemore » iPhone 3GS and a Cs-137 irradiator. The charge-coupled device (CCD) camera on the phone was irradiated to exposure rates ranging from 0.1 mR/hr to 100 mR/hr and 30-sec videos were taken during irradiation with the camera lens covered by electrical tape. Interactions were detected as white pixels on a black background in each video. Both single threshold (ST) and colony counting (CC) methods were performed using MATLAB®. Calibration curves were determined by comparing the total pixel intensity output from each method to the known exposure rate. Results: The calibration curve showed a linear relationship above 5 mR/hr for both analysis techniques. The number of events counted per unit exposure rate within the linear region was 19.5 ± 0.7 events/mR and 8.9 ± 0.4 events/mR for the ST and CC methods respectively. Conclusion: Two algorithms were developed and show a linear relationship between photons detected by a CCD camera and low exposure rates, in the range of 5 mR/hr to 100-mR/hr. Future work aims to refine this model by investigating the dose-rate and energy dependencies of the camera response. This algorithm allows for quantitative monitoring of exposure from patients treated with iodine-131 using a simple device outside of the hospital.« less
Radioactive Quality Evaluation and Cross Validation of Data from the HJ-1A/B Satellites' CCD Sensors
Zhang, Xin; Zhao, Xiang; Liu, Guodong; Kang, Qian; Wu, Donghai
2013-01-01
Data from multiple sensors are frequently used in Earth science to gain a more complete understanding of spatial information changes. Higher quality and mutual consistency are prerequisites when multiple sensors are jointly used. The HJ-1A/B satellites successfully launched on 6 September 2008. There are four charge-coupled device (CCD) sensors with uniform spatial resolutions and spectral range onboard the HJ-A/B satellites. Whether these data are keeping consistency is a major issue before they are used. This research aims to evaluate the data consistency and radioactive quality from the four CCDs. First, images of urban, desert, lake and ocean are chosen as the objects of evaluation. Second, objective evaluation variables, such as mean, variance and angular second moment, are used to identify image performance. Finally, a cross validation method are used to ensure the correlation of the data from the four HJ-1A/B CCDs and that which is gathered from the moderate resolution imaging spectro-radiometer (MODIS). The results show that the image quality of HJ-1A/B CCDs is stable, and the digital number distribution of CCD data is relatively low. In cross validation with MODIS, the root mean square errors of bands 1, 2 and 3 range from 0.055 to 0.065, and for band 4 it is 0.101. The data from HJ-1A/B CCD have better consistency. PMID:23881127
Zhang, Xin; Zhao, Xiang; Liu, Guodong; Kang, Qian; Wu, Donghai
2013-07-05
Data from multiple sensors are frequently used in Earth science to gain a more complete understanding of spatial information changes. Higher quality and mutual consistency are prerequisites when multiple sensors are jointly used. The HJ-1A/B satellites successfully launched on 6 September 2008. There are four charge-coupled device (CCD) sensors with uniform spatial resolutions and spectral range onboard the HJ-A/B satellites. Whether these data are keeping consistency is a major issue before they are used. This research aims to evaluate the data consistency and radioactive quality from the four CCDs. First, images of urban, desert, lake and ocean are chosen as the objects of evaluation. Second, objective evaluation variables, such as mean, variance and angular second moment, are used to identify image performance. Finally, a cross validation method are used to ensure the correlation of the data from the four HJ-1A/B CCDs and that which is gathered from the moderate resolution imaging spectro-radiometer (MODIS). The results show that the image quality of HJ-1A/B CCDs is stable, and the digital number distribution of CCD data is relatively low. In cross validation with MODIS, the root mean square errors of bands 1, 2 and 3 range from 0.055 to 0.065, and for band 4 it is 0.101. The data from HJ-1A/B CCD have better consistency.
VizieR Online Data Catalog: Observed light curve of (3200) Phaethon (Ansdell+, 2014)
NASA Astrophysics Data System (ADS)
Ansdell, M.; Meech, K. J.; Hainaut, O.; Buie, M. W.; Kaluna, H.; Bauer, J.; Dundon, L.
2017-04-01
We obtained time series photometry over 15 nights from 1994 to 2013. All but three nights used the Tektronix 2048x2048 pixel CCD camera on the University of Hawaii 2.2 m telescope on Mauna Kea. Two nights used the PRISM 2048x2048 pixel CCD camera on the Perkins 72 inch telescope at the Lowell Observatory in Flagstaff, Arizona, while one night used the Optic 2048x4096 CCD camera also on the University of Hawaii 2.2 m telescope. All observations used the standard Kron-Cousins R filter with the telescope guiding on (3200) Phaethon at non-sidereal rates. Raw images were processed with standard IRAF routines for bias subtraction, flat-fielding, and cosmic ray removal (Tody, 1986SPIE..627..733T). We constructed reference flat fields by median combining dithered images of either twilight or the object field (in both cases, flattening reduced gradients to <1% across the CCD). We performed photometry using the IRAF phot routine with circular apertures typically 5'' in radius, although aperture sizes changed depending on the night and/or exposure as they were chosen to consistently include 99.5% of the object's light. (1 data file).
A simple, low-cost, versatile CCD spectrometer for plasma spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Den Hartog, D. J.; Holly, D. J.
1996-06-01
The authors have constructed a simple, low-cost CCD spectrometer capable of both high resolution ({Delta}{lambda} {le} 0.015 nm) and large bandpass (110 nm with {Delta}{lambda} {approximately}0.3 nm). These two modes of operation provide two broad areas of capability for plasma spectroscopy. The first major application is measurement of emission line broadening; the second is emission line surveys from the ultraviolet to the near infrared. Measurements have been made on a low-temperature plasma produced by a miniature electrostatic plasma source and the high-temperature plasma in the MST Reversed-Field Pinch. The spectrometer is a modified Jarrell-Ash 0.5 m Ebert-Fastie monochromator. Light ismore » coupled into the entrance slit with a fused silica fiber optic bundle. The exposure time (2 ms minimum) is controlled by a fast electromechanical shutter. The exit plane detector is a compact and robust CCD detector developed for amateur astronomy by Santa Barbara Instrument Group. The CCD detector is controlled and read out by a Macintosh{reg_sign} computer. This spectrometer is sophisticated enough to serve well in a research laboratory, yet is simple and inexpensive enough to be affordable for instructional use.« less
Camera for Quasars in the Early Universe (CQUEAN)
NASA Astrophysics Data System (ADS)
Kim, Eunbin; Park, W.; Lim, J.; Jeong, H.; Kim, J.; Oh, H.; Pak, S.; Im, M.; Kuehne, J.
2010-05-01
The early universe of z ɳ is where the first stars, galaxies, and quasars formed, starting the re-ionization of the universe. The discovery and the study of quasars in the early universe allow us to witness the beginning of history of astronomical objects. In order to perform a medium-deep, medium-wide, imaging survey of quasars, we are developing an optical CCD camera, CQUEAN (Camera for QUasars in EArly uNiverse) which uses a 1024*1024 pixel deep-depletion CCD. It has an enhanced QE than conventional CCD at wavelength band around 1μm, thus it will be an efficient tool for observation of quasars at z > 7. It will be attached to the 2.1m telescope at McDonald Observatory, USA. A focal reducer is designed to secure a larger field of view at the cassegrain focus of 2.1m telescope. For long stable exposures, auto-guiding system will be implemented by using another CCD camera viewing an off-axis field. All these instruments will be controlled by the software written in python on linux platform. CQUEAN is expected to see the first light during summer in 2010.
NASA Astrophysics Data System (ADS)
Takashima, Ichiro; Kajiwara, Riichi; Murano, Kiyo; Iijima, Toshio; Morinaka, Yasuhiro; Komobuchi, Hiroyoshi
2001-04-01
We have designed and built a high-speed CCD imaging system for monitoring neural activity in an exposed animal cortex stained with a voltage-sensitive dye. Two types of custom-made CCD sensors were developed for this system. The type I chip has a resolution of 2664 (H) X 1200 (V) pixels and a wide imaging area of 28.1 X 13.8 mm, while the type II chip has 1776 X 1626 pixels and an active imaging area of 20.4 X 18.7 mm. The CCD arrays were constructed with multiple output amplifiers in order to accelerate the readout rate. The two chips were divided into either 24 (I) or 16 (II) distinct areas that were driven in parallel. The parallel CCD outputs were digitized by 12-bit A/D converters and then stored in the frame memory. The frame memory was constructed with synchronous DRAM modules, which provided a capacity of 128 MB per channel. On-chip and on-memory binning methods were incorporated into the system, e.g., this enabled us to capture 444 X 200 pixel-images for periods of 36 seconds at a rate of 500 frames/second. This system was successfully used to visualize neural activity in the cortices of rats, guinea pigs, and monkeys.
VizieR Online Data Catalog: Ultracool white dwarfs (Gianninas+, 2015)
NASA Astrophysics Data System (ADS)
Gianninas, A.; Curd, B.; Thorstensen, J. R.; Kilic, M.; Bergeron, P.; Andrews, J. J.; Canton, P.; Agueros, M. A.
2015-11-01
All our parallax data are from the 2.4m Hiltner telescope at Michigan-Dartmouth-MIT (MDM) Observatory on Kitt Peak, Arizona. We used a thinned SITe CCD (named 'echelle'); at the f7.5 focus, each 24um pixel subtended 0.275-arcsec, giving a field of view 9.4arcmin2. For all our parallax data, we used a 4-inch-square Kron-Cousins I-band filter, which did not vignette the CCD. Exposure times varied with the brightness of the object, but were typically a few hundred seconds. Our data were taken on numerous observing runs between 2007 and 2011. (4 data files).
Astrometric Quality of the USNO CCD Astrograph (UCA)
NASA Astrophysics Data System (ADS)
Zacharias, N.
1997-05-01
The USNO 8-inch astrograph has been equipped with a Kodak 1536x1024 pixel CCD since June 1995, operating in a 570-650 nm bandpass. With 3-minute exposures well exposed images are obtained in the magnitude range R ~ 8.5 - 13.5(m) . An astrometric precision of 10 to 15 mas for those stars is estimated from frame-to-frame comparisons. External comparisons reveal an accuracy of about 15 mas for those stars in a 20' field of view. For fainter stars, the error budget is dominated by the S/N ratio, reaching ~ 100 mas at R=16(m) under good observing conditions.
CCD sensors in synchrotron X-ray detectors
NASA Astrophysics Data System (ADS)
Strauss, M. G.; Naday, I.; Sherman, I. S.; Kraimer, M. R.; Westbrook, E. M.; Zaluzec, N. J.
1988-04-01
The intense photon flux from advanced synchrotron light sources, such as the 7-GeV synchrotron being designed at Argonne, require integrating-type detectors. Charge-coupled devices (CCDs) are well suited as synchrotron X-ray detectors. When irradiated indirectly via a phosphor followed by reducing optics, diffraction patterns of 100 cm 2 can be imaged on a 2 cm 2 CCD. With a conversion efficiency of ˜ 1 CCD electron/X-ray photon, a peak saturation capacity of > 10 6 X-rays can be obtained. A programmable CCD controller operating at a clock frequency of 20 MHz has been developed. The readout rate is 5 × 10 6 pixels/s and the shift rate in the parallel registers is 10 6 lines/s. The test detector was evaluated in two experiments. In protein crystallography diffraction patterns have been obtained from a lysozyme crystal using a conventional rotating anode X-ray generator. Based on these results we expect to obtain at a synchrotron diffraction images at a rate of ˜ 1 frame/s or a complete 3-dimensional data set from a single crystal in ˜ 2 min. In electron energy-loss spectroscopy (EELS), the CCD was used in a parallel detection mode which is similar to the mode array detectors are used in dispersive EXAFS. With a beam current corresponding to 3 × 10 9 electron/s on the detector, a series of 64 spectra were recorded on the CCD in a continuous sequence without interruption due to readout. The frame-to-frame pixel signal fluctuations had σ = 0.4% from which DQE = 0.4 was obtained, where the detector conversion efficiency was 2.6 CCD electrons/X-ray photon. These multiple frame series also showed the time-resolved modulation of the electron microscope optics by stray magnetic fields.
Orthodontic treatment of a patient with cleidocranial dysplasia: A case report.
Li, Zi-Jian; Wang, Jun-Yan; Gao, Ming-Fei; Wu, Da-Lei; Chang, Xin
2016-08-01
Cleidocranial dysplasia (CCD) is a rare autosomal dominant condition that affects ossification. The dental abnormalities associated with CCD present an obstacle to orthodontic treatment planning. Early diagnosis is crucial to provide the patient with different treatment modalities that will suit the particular patient. In the present case, combined surgical and orthodontic treatment were performed to guide multiple impacted teeth. A single nucleotide missense variation was identified in exon 3 of runt-related transcription factor 2 ( RUNX2 ) in this patient. The current results suggest a correlation between dental alterations and mutations in the runt domain of RUNX2 in CCD patients. Further clinical and genetic studies may required to confirm the association between phenotypes and genotypes in CCD and to identify other factors that may influence the clinical features of this disease. Patients with cleidocranial dysplasia require a team approach which demands good communication and cooperation from the patient. Timing of the intervention is critical, and numerous surgeries may be required. The patient in the present case report was treated by a team of practitioners, which involved several dental specialties to achieve an optimal result.
Li, Rui; Elson, Daniel S; Dunsby, Chris; Eckersley, Robert; Tang, Meng-Xing
2011-04-11
Ultrasound-modulated optical tomography (UOT) combines optical contrast with ultrasound spatial resolution and has great potential for soft tissue functional imaging. One current problem with this technique is the weak optical modulation signal, primarily due to strong optical scattering in diffuse media and minimal acoustically induced modulation. The acoustic radiation force (ARF) can create large particle displacements in tissue and has been shown to be able to improve optical modulation signals. However, shear wave propagation induced by the ARF can be a significant source of nonlocal optical modulation which may reduce UOT spatial resolution and contrast. In this paper, the time evolution of shear waves was examined on tissue mimicking-phantoms exposed to 5 MHz ultrasound and 532 nm optical radiation and measured with a CCD camera. It has been demonstrated that by generating an ARF with an acoustic burst and adjusting both the timing and the exposure time of the CCD measurement, optical contrast and spatial resolution can be improved by ~110% and ~40% respectively when using the ARF rather than 5 MHz ultrasound alone. Furthermore, it has been demonstrated that this technique simultaneously detects both optical and mechanical contrast in the medium and the optical and mechanical contrast can be distinguished by adjusting the CCD exposure time. © 2011 Optical Society of America
Bee cups: Single-use cages for honey bee experiments
USDA-ARS?s Scientific Manuscript database
Honey bees face challenges ranging from poor nutrition to exposure to parasites, pathogens, and environmental chemicals. These challenges drain colony resources and have been tied to both subtle and extreme colony declines, including the enigmatic Colony Collapse Disorder (CCD). Understanding how ...
Farooqui, Tahira
2013-01-01
Pesticides are substances that have been widely used throughout the world to kill, repel, or control organisms such as certain forms of plants or animals considered as pests. Depending on their type, dose, and persistence in the environment, they can have impact even on non-target species such as beneficial insects (honeybees) in different ways, including reduction in their survival rate and interference with their reproduction process. Honeybee Apis mellifera is a major pollinator and has substantial economical and ecological values. Colony collapse disorder (CCD) is a mysterious phenomenon in which adult honeybee workers suddenly abandon from their hives, leaving behind food, brood, and queen. It is lately drawing a lot of attention due to pollination crisis as well as global agriculture and medical demands. If the problem of CCD is not resolved soon enough, this could have a major impact on food industry affecting world's economy a big time. Causes of CCD are not known. In this overview, I discuss CCD, biogenic amines-based-pesticides (neonicotinoids and formamidines), and their disruptive effects on biogenic amine signaling causing olfactory dysfunction in honeybees. According to my hypothesis, chronic exposure of biogenic amines-based-pesticides to honeybee foragers in hives and agricultural fields can disrupt neural cholinergic and octopaminergic signaling. Abnormality in biogenic amines-mediated neuronal signaling impairs their olfactory learning and memory, therefore foragers do not return to their hive - a possible cause of CCD. This overview is an attempt to discuss a hypothetical link among biogenic amines-based pesticides, olfactory learning and memory, and CCD. Copyright © 2012 Elsevier Ltd. All rights reserved.
The Development of the Spanish Fireball Network Using a New All-Sky CCD System
NASA Astrophysics Data System (ADS)
Trigo-Rodríguez, J. M.; Castro-Tirado, A. J.; Llorca, J.; Fabregat, J.; Martínez, V. J.; Reglero, V.; Jelínek, M.; Kubánek, P.; Mateo, T.; Postigo, A. De Ugarte
2004-12-01
We have developed an all-sky charge coupled devices (CCD) automatic system for detecting meteors and fireballs that will be operative in four stations in Spain during 2005. The cameras were developed following the BOOTES-1 prototype installed at the El Arenosillo Observatory in 2002, which is based on a CCD detector of 4096 × 4096 pixels with a fish-eye lens that provides an all-sky image with enough resolution to make accurate astrometric measurements. Since late 2004, a couple of cameras at two of the four stations operate for 30 s in alternate exposures, allowing 100% time coverage. The stellar limiting magnitude of the images is +10 in the zenith, and +8 below ~ 65° of zenithal angle. As a result, the images provide enough comparison stars to make astrometric measurements of faint meteors and fireballs with an accuracy of ~ 2°arcminutes. Using this prototype, four automatic all-sky CCD stations have been developed, two in Andalusia and two in the Valencian Community, to start full operation of the Spanish Fireball Network. In addition to all-sky coverage, we are developing a fireball spectroscopy program using medium field lenses with additional CCD cameras. Here we present the first images obtained from the El Arenosillo and La Mayora stations in Andalusia during their first months of activity. The detection of the Jan 27, 2003 superbolide of ± 17 ± 1 absolute magnitude that overflew Algeria and Morocco is an example of the detection capability of our prototype.
Wide field NEO survey 1.0-m telescope with 10 2k×4k mosaic CCD camera
NASA Astrophysics Data System (ADS)
Isobe, Syuzo; Asami, Atsuo; Asher, David J.; Hashimoto, Toshiyasu; Nakano, Shi-ichi; Nishiyama, Kota; Ohshima, Yoshiaki; Terazono, Junya; Umehara, Hiroaki; Yoshikawa, Makoto
2002-12-01
We developed a new 1.0 m telescope with a 3 degree flat focal plane to which a mosaic CCD camera with 10 2k×4k chips is fixed. The system was set up in February 2002, and is now undergoing the final fine adjustments. Since the telescope has a focal length of 3 m, a field of 7.5 square degrees is covered in one image. In good seeing conditions, 1.5 arc seconds, at the site located in Bisei town, Okayama prefecture in Japan, we can expect to detect down to 20th magnitude stars with an exposure time of 60 seconds. Considering a read-out time, 46 seconds, of the CCD camera, one image is taken in every two minutes, and about 2,100 square degrees of field is expected to be covered in one clear night. This system is very effective for survey work, especially for Near-Earth-Asteroid detection.
VizieR Online Data Catalog: Hα images of HD93521 (Rauw+, 2012)
NASA Astrophysics Data System (ADS)
Rauw, G.; Morel, T.; Palate, M.
2012-09-01
The best quality H-alpha images of the field around HD93521 are provided. These data were obtained by amateur astronomer Gaston Dessy (member of the Society Astronomique de Liege, Belgium) with a TMB-92 9.2cm refractor. The first image (haskyco1.fit) was taken with an Atik 16IC CCD and is the combination of 15 individual 5min exposures. The field of view covers 41x30.8-arcmin squared. HD93521 and BD+38 2183 are located on the pixels (328, 230) and (218, 390) respectively. A flat sky background was subtracted. The second image (haskyco2.fit) was taken with an Atik 4000M CCD and is the combination of 12 individual 5min exposures. The field of view covers 127.7x127.7arcmin squared. HD93521 and BD+38 2183 are located on the pixels (1109, 1545) and (989, 1385) respectively. A flat sky background was subtracted. (2 data files).
Handling of huge multispectral image data volumes from a spectral hole burning device (SHBD)
NASA Astrophysics Data System (ADS)
Graff, Werner; Rosselet, Armel C.; Wild, Urs P.; Gschwind, Rudolf; Keller, Christoph U.
1995-06-01
We use chlorin-doped polymer films at low temperatures as the primary imaging detector. Based on the principles of persistent spectral hole burning, this system is capable of storing spatial and spectral information simultaneously in one exposure with extremely high resolution. The sun as an extended light source has been imaged onto the film. The information recorded amounts to tens of GBytes. This data volume is read out by scanning the frequency of a tunable dye laser and reading the images with a digital CCD camera. For acquisition, archival, processing, and visualization, we use MUSIC (MUlti processor System with Intelligent Communication), a single instruction multiple data parallel processor system equipped with the necessary I/O facilities. The huge amount of data requires the developemnt of sophisticated algorithms to efficiently calibrate the data and to extract useful and new information for solar physics.
Adjustment of multi-CCD-chip-color-camera heads
NASA Astrophysics Data System (ADS)
Guyenot, Volker; Tittelbach, Guenther; Palme, Martin
1999-09-01
The principle of beam-splitter-multi-chip cameras consists in splitting an image into differential multiple images of different spectral ranges and in distributing these onto separate black and white CCD-sensors. The resulting electrical signals from the chips are recombined to produce a high quality color picture on the monitor. Because this principle guarantees higher resolution and sensitivity in comparison to conventional single-chip camera heads, the greater effort is acceptable. Furthermore, multi-chip cameras obtain the compete spectral information for each individual object point while single-chip system must rely on interpolation. In a joint project, Fraunhofer IOF and STRACON GmbH and in future COBRA electronic GmbH develop methods for designing the optics and dichroitic mirror system of such prism color beam splitter devices. Additionally, techniques and equipment for the alignment and assembly of color beam splitter-multi-CCD-devices on the basis of gluing with UV-curable adhesives have been developed, too.
[Orthodontic and oral surgery therapy in cleidocranial dysplasia].
Balaton, Gergely; Tarján, Ildikó; Balaton, Péter; Barabási, Zoltán; Gyulai Gál, Szabolcs; Nagy, Katalin; Vajó, Zoltán
2007-02-01
A cleidocranial dysplasia is an autosomal dominant inherited condition consisting of generalized skeletal disorder. Associated dental signs are present in 93,5%; failure of tooth eruption with multiple supernumerary teeth, dilaceration of roots, crown germination, microdontia, high arched palate, midface hypoplasia, high gonion angle. The molecular- genetic analysis revealed a missense mutation in the CBFA1 gene located on chromosome 6p21, which is considered to be etiological factor for CCD. Orthodontic and oral surgery therapy of a 13 year-old child with CCD was performed due to aesthetic and functional problems. The supernumerary germs were removed and the teeth were aligned with orthodontic appliances. Temporary functional rehabilitation was solved with partial denture. The presented case and the literature data support the importance of early diagnosis of CCD. The good collaboration of the orthodontic and maxillo-facial surgery specialists help achieve the correct rehabilitation of the patient.
VanEngelsdorp, Dennis; Speybroeck, Niko; Evans, Jay D; Nguyen, Bach Kim; Mullin, Chris; Frazier, Maryann; Frazier, Jim; Cox-Foster, Diana; Chen, Yanping; Tarpy, David R; Haubruge, Eric; Pettis, Jeffrey S; Saegerman, Claude
2010-10-01
Colony collapse disorder (CCD), a syndrome whose defining trait is the rapid loss of adult worker honey bees, Apis mellifera L., is thought to be responsible for a minority of the large overwintering losses experienced by U.S. beekeepers since the winter 2006-2007. Using the same data set developed to perform a monofactorial analysis (PloS ONE 4: e6481, 2009), we conducted a classification and regression tree (CART) analysis in an attempt to better understand the relative importance and interrelations among different risk variables in explaining CCD. Fifty-five exploratory variables were used to construct two CART models: one model with and one model without a cost of misclassifying a CCD-diagnosed colony as a non-CCD colony. The resulting model tree that permitted for misclassification had a sensitivity and specificity of 85 and 74%, respectively. Although factors measuring colony stress (e.g., adult bee physiological measures, such as fluctuating asymmetry or mass of head) were important discriminating values, six of the 19 variables having the greatest discriminatory value were pesticide levels in different hive matrices. Notably, coumaphos levels in brood (a miticide commonly used by beekeepers) had the highest discriminatory value and were highest in control (healthy) colonies. Our CART analysis provides evidence that CCD is probably the result of several factors acting in concert, making afflicted colonies more susceptible to disease. This analysis highlights several areas that warrant further attention, including the effect of sublethal pesticide exposure on pathogen prevalence and the role of variability in bee tolerance to pesticides on colony survivorship.
Digital Mammography with a Mosaic of CCD Arrays
NASA Technical Reports Server (NTRS)
Jalink, Antony, Jr. (Inventor); McAdoo, James A. (Inventor)
1998-01-01
A digital mammography device uses a mosaic of electronic digital imaging arrays to scan an x-ray image is discussed. The mosaic of arrays is repositioned several times to expose different portions of the image, until the entire image is scanned. The data generated by the arrays during each exposure is stored in a computer. After the final exposure, the computer combines data of the several partial images to produce a composite of the original x-ray image. An aperture plate is used to reduce scatter and the overall exposure of the patient to x-rays.
Klein, Dawn M; Pham, Kassi; Samy, Leila; Bluth, Adam; Nazi, Kim M; Witry, Matthew; Klutts, J Stacey; Grant, Kathleen M; Gundlapalli, Adi V; Kochersberger, Gary; Pfeiffer, Laurie; Romero, Sergio; Vetter, Brian; Turvey, Carolyn L
2017-04-01
Information continuity is critical to person-centered care when patients receive care from multiple healthcare systems. Patients can access their electronic health record data through patient portals to facilitate information exchange. This pilot was developed to improve care continuity for rural Veterans by (1) promoting the use of the Department of Veterans Affairs (VA) patient portal to share health information with non-VA providers, and (2) evaluating the impact of health information sharing at a community appointment. Veterans from nine VA healthcare systems were trained to access and share their VA Continuity of Care Document (CCD) with their non-VA providers. Patients and non-VA providers completed surveys on their experiences. Participants (n = 620) were primarily older, white, and Vietnam era Veterans. After training, 78% reported the CCD would help them be more involved in their healthcare and 86% planned to share it regularly with non-VA providers. Veterans (n = 256) then attended 277 community appointments. Provider responses from these appointments (n = 133) indicated they were confident in the accuracy of the information (97%) and wanted to continue to receive the CCD (96%). Ninety percent of providers reported the CCD improved their ability to have an accurate medication list and helped them make medication treatment decisions. Fifty percent reported they did not order a laboratory test or another procedure because of information available in the CCD. This pilot demonstrates feasibility and value of patient access to a CCD to facilitate information sharing between VA and non-VA providers. Outreach and targeted education are needed to promote consumer-mediated health information exchange.
NASA Astrophysics Data System (ADS)
Swain, Pradyumna; Mark, David
2004-09-01
The emergence of curved CCD detectors as individual devices or as contoured mosaics assembled to match the curved focal planes of astronomical telescopes and terrestrial stereo panoramic cameras represents a major optical design advancement that greatly enhances the scientific potential of such instruments. In altering the primary detection surface within the telescope"s optical instrumentation system from flat to curved, and conforming the applied CCD"s shape precisely to the contour of the telescope"s curved focal plane, a major increase in the amount of transmittable light at various wavelengths through the system is achieved. This in turn enables multi-spectral ultra-sensitive imaging with much greater spatial resolution necessary for large and very large telescope applications, including those involving infrared image acquisition and spectroscopy, conducted over very wide fields of view. For earth-based and space-borne optical telescopes, the advent of curved CCD"s as the principle detectors provides a simplification of the telescope"s adjoining optics, reducing the number of optical elements and the occurrence of optical aberrations associated with large corrective optics used to conform to flat detectors. New astronomical experiments may be devised in the presence of curved CCD applications, in conjunction with large format cameras and curved mosaics, including three dimensional imaging spectroscopy conducted over multiple wavelengths simultaneously, wide field real-time stereoscopic tracking of remote objects within the solar system at high resolution, and deep field survey mapping of distant objects such as galaxies with much greater multi-band spatial precision over larger sky regions. Terrestrial stereo panoramic cameras equipped with arrays of curved CCD"s joined with associative wide field optics will require less optical glass and no mechanically moving parts to maintain continuous proper stereo convergence over wider perspective viewing fields than their flat CCD counterparts, lightening the cameras and enabling faster scanning and 3D integration of objects moving within a planetary terrain environment. Preliminary experiments conducted at the Sarnoff Corporation indicate the feasibility of curved CCD imagers with acceptable electro-optic integrity. Currently, we are in the process of evaluating the electro-optic performance of a curved wafer scale CCD imager. Detailed ray trace modeling and experimental electro-optical data performance obtained from the curved imager will be presented at the conference.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sadler, D.A.; Sun, F.; Littlejohn, D.
1995-12-31
ICP-OES is a useful technique for multi-element analysis of soils. However, as a number of elements are present in relatively high concentrations, matrix interferences can occur and examples have been widely reported. The availability of CCD detectors has increased the opportunities for rapid multi-element, multi-wave-length determination of elemental concentrations in soils and other environmental samples. As the composition of soils from industrial sites can vary considerably, especially when taken from different pit horizons, procedures are required to assess the extent of interferences and correct the effects, on a simultaneous multi-element basis. In single element analysis, plasma operating conditions can sometimesmore » be varied to minimize or even remove multiplicative interferences. In simultaneous multi-element analysis, the scope for this approach may be limited, depending on the spectrochemical characteristics of the emitting analyte species. Matrix matching, by addition of major sample components to the analyte calibrant solutions, can be used to minimize inaccuracies. However, there are also limitations to this procedure, when the sample composition varies significantly. Multiplicative interference effects can also be assessed by a {open_quotes}single standard addition{close_quotes} of each analyte to the sample solution and the information obtained may be used to correct the analyte concentrations determined directly. Each of these approaches has been evaluated to ascertain the best procedure for multi-element analysis of industrial soils by ICP-OES with CCD detection at multiple wavelengths. Standard reference materials and field samples have been analyzed to illustrate the efficacy of each procedure.« less
The design and development of low- and high-voltage ASICs for space-borne CCD cameras
NASA Astrophysics Data System (ADS)
Waltham, N.; Morrissey, Q.; Clapp, M.; Bell, S.; Jones, L.; Torbet, M.
2017-12-01
The CCD remains the pre-eminent visible and UV wavelength image sensor in space science, Earth and planetary remote sensing. However, the design of space-qualified CCD readout electronics is a significant challenge with requirements for low-volume, low-mass, low-power, high-reliability and tolerance to space radiation. Space-qualified components are frequently unavailable and up-screened commercial components seldom meet project or international space agency requirements. In this paper, we describe an alternative approach of designing and space-qualifying a series of low- and high-voltage mixed-signal application-specific integrated circuits (ASICs), the ongoing development of two low-voltage ASICs with successful flight heritage, and two new high-voltage designs. A challenging sub-system of any CCD camera is the video processing and digitisation electronics. We describe recent developments to improve performance and tolerance to radiation-induced single event latchup of a CCD video processing ASIC originally developed for NASA's Solar Terrestrial Relations Observatory and Solar Dynamics Observatory. We also describe a programme to develop two high-voltage ASICs to address the challenges presented with generating a CCD's bias voltages and drive clocks. A 0.35 μm, 50 V tolerant, CMOS process has been used to combine standard low-voltage 3.3 V transistors with high-voltage 50 V diffused MOSFET transistors that enable output buffers to drive CCD bias drains, gates and clock electrodes directly. We describe a CCD bias voltage generator ASIC that provides 24 independent and programmable 0-32 V outputs. Each channel incorporates a 10-bit digital-to-analogue converter, provides current drive of up to 20 mA into loads of 10 μF, and includes current-limiting and short-circuit protection. An on-chip telemetry system with a 12-bit analogue-to-digital converter enables the outputs and multiple off-chip camera voltages to be monitored. The ASIC can drive one or more CCDs and replaces the many discrete components required in current cameras. We also describe a CCD clock driver ASIC that provides six independent and programmable drivers with high-current capacity. The device enables various CCD clock parameters to be programmed independently, for example the clock-low and clock-high voltage levels, and the clock-rise and clock-fall times, allowing configuration for serial clock frequencies in the range 0.1-2 MHz and image clock frequencies in the range 10-100 kHz. Finally, we demonstrate the impact and importance of this technology for the development of compact, high-performance and low-power integrated focal plane electronics.
X-Ray Spectroscopy of Optically Bright Planets using the Chandra Observatory
NASA Technical Reports Server (NTRS)
Ford, P. G.; Elsner, R. F.
2005-01-01
Since its launch in July 1999, Chandra's Advanced CCD Imaging Spectrometer (ACIS) has observed several planets (Venus, Mars, Jupiter and Saturn) and 6 comets. At 0.5 arc-second spatial resolution, ACIS detects individual x-ray photons with good quantum efficiency (25% at 0.6 KeV) and energy resolution (20% FWHM at 0.6 KeV). However, the ACIS CCDs are also sensitive to optical and near-infrared light, which is absorbed by optical blocking filters (OBFs) that eliminate optical contamination from all but the brightest extended sources, e.g., planets. .Jupiter at opposition subseconds approx.45 arc-seconds (90 CCD pixels.) Since Chandra is incapable of tracking a moving target, the planet takes 10 - 20 kiloseconds to move across the most sensitive ACIS CCD, after which the observatory must be re-pointed. Meanwhile, the OBF covering that CCD adds an opt,ical signal equivalent to approx.110 eV to each pixel that lies within thc outline of the Jovian disk. This has three consequences: (1) the observatory must be pointed away from Jupiter while CCD bias maps are constructed; (2) most x-rays from within the optical image will be misidentified as charged-particle background and ignored; and (3) those x-rays that are reported will bc assigned anomalously high energies. The same also applies to thc other planets, but is less serious since they are either dimmer at optical wavelengths, or they show less apparent motion across the sky, permitting reduced CCD exposure times: the optical contamination from Saturn acids approx.15 eV per pixel, and from Mars and Venus approx.31 eV. After analyzing a series of short .Jupiter observations in December 2000, ACIS parameters were optimized for the February 2003 opposition. CCD bias maps were constructed while Chandra pointed away from Jupiter, and the subsequent observations employed on-board software to ignore any pixel that contained less charge than that expected from optical leakage. In addition, ACIS was commanded to report 5 x 5 arrays of pixel values surrounding each x-ray event, and the outlying values were employed during ground processing to correct for the optical contamination.
VizieR Online Data Catalog: BV(RI)c light curves of NSVS 5066754 (Samec+, 2016)
NASA Astrophysics Data System (ADS)
Samec, R. G.; Nyaude, R.; Caton, D. B.; Faulkner, D. R.
2017-01-01
Our BVRcIc light curves were taken with the Dark 0.81m reflector at Philips Gap, North Carolina, on 17-20 inclusive, 2014 May with a thermoelectrically cooled (-40°C) 2K*2K Apogee Alta U44 CCD using standard Johnson-Cousins BVRcIc filters (320 observations with an exposure time of 60s in B, 333 observations with an exposure time of 24s in V, 338 observations with an exposure time of 20s in Rc, and 258 observations with an exposure time of 20s in Ic). Our complete set of observations is given in Table2. (1 data file).
The Operation and Evolution of the Swift X-ray Telescope
NASA Technical Reports Server (NTRS)
Kennea, Jamie; Burrows, D. N.; Pagani, C.; Hill, Joanne; Racusin, J. L.; Morris, D. C.; Abbey, A. F.; Beardmore, A. P.; Campana, G.; Chincarini, G.;
2007-01-01
The Swift X-ray Telescope (XRT) is a CCD based X-ray telescope designed for localization, spectroscopy and long term light curve monitoring of Gamma-Ray Bursts and their X-ray afterglows. Since the launch of Swift in November 2004, the XRT has undergone significant evolution in the way it is operated. Shortly after launch there was a failure of the thermo-electric cooler on the XRT CCD, which led to the XRT team being required to devise a method of keeping the XRT CCD temperature below 50C utilizing only passive cooling by minimizing the exposure of the XRT radiator to the Earth. We present in this paper an update on how the modeling of this passive cooling method has improved in first -1000 days since the method was devised, and the success rate of this method in day-to-day planning. We also discuss the changes to the operational modes and onboard software of the XRT. These changes include improved rapid data product generation in order to improve speed of rapid Gamma-Ray Burst response and localization to the community; changes to the way XRT observation modes are chosen in order to better fine tune data aquisition to a particular science goal; reduction of "mode switching" caused by the contamination of the CCD by Earth light or high temperature effects.
Ultrasound-modulated optical tomography with intense acoustic bursts.
Zemp, Roger J; Kim, Chulhong; Wang, Lihong V
2007-04-01
Ultrasound-modulated optical tomography (UOT) detects ultrasonically modulated light to spatially localize multiply scattered photons in turbid media with the ultimate goal of imaging the optical properties in living subjects. A principal challenge of the technique is weak modulated signal strength. We discuss ways to push the limits of signal enhancement with intense acoustic bursts while conforming to optical and ultrasonic safety standards. A CCD-based speckle-contrast detection scheme is used to detect acoustically modulated light by measuring changes in speckle statistics between ultrasound-on and ultrasound-off states. The CCD image capture is synchronized with the ultrasound burst pulse sequence. Transient acoustic radiation force, a consequence of bursts, is seen to produce slight signal enhancement over pure ultrasonic-modulation mechanisms for bursts and CCD exposure times of the order of milliseconds. However, acoustic radiation-force-induced shear waves are launched away from the acoustic sample volume, which degrade UOT spatial resolution. By time gating the CCD camera to capture modulated light before radiation force has an opportunity to accumulate significant tissue displacement, we reduce the effects of shear-wave image degradation, while enabling very high signal-to-noise ratios. Additionally, we maintain high-resolution images representative of optical and not mechanical contrast. Signal-to-noise levels are sufficiently high so as to enable acquisition of 2D images of phantoms with one acoustic burst per pixel.
Dark Energy Camera (DECam) | CTIO
DECam SAM 0.9-m CCD Goodman SOI Optical Spectrographs CHIRON COSMOS Goodman Filters Telescopes Blanco 4 affecting mainly short exposures taken with bluer filters in dark conditions. 2015 Dec. A new filter, N964 the SDSS filters, has been successfully installed. Images are still being evaluated, but looks good
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Ang; Yu, Heng; Tozzi, Paolo
2016-04-10
We search for bulk motions in the intracluster medium (ICM) of massive clusters showing evidence of an ongoing or recent major merger with spatially resolved spectroscopy in Chandra CCD data. We identify a sample of six merging clusters with >150 ks Chandra exposure in the redshift range 0.1 < z < 0.3. By performing X-ray spectral analysis of projected ICM regions selected according to their surface brightness, we obtain the projected redshift maps for all of these clusters. After performing a robust analysis of the statistical and systematic uncertainties in the measured X-ray redshift z{sub X}, we check whether or not themore » global z{sub X} distribution differs from that expected when the ICM is at rest. We find evidence of significant bulk motions at more than 3σ in A2142 and A115, and less than 2σ in A2034 and A520. Focusing on single regions, we identify significant localized velocity differences in all of the merger clusters. We also perform the same analysis on two relaxed clusters with no signatures of recent mergers, finding no signs of bulk motions, as expected. Our results indicate that deep Chandra CCD data enable us to identify the presence of bulk motions at the level of v{sub BM} > 1000 km s{sup −1} in the ICM of massive merging clusters at 0.1 < z < 0.3. Although the CCD spectral resolution is not sufficient for a detailed analysis of the ICM dynamics, Chandra CCD data constitute a key diagnostic tool complementing X-ray bolometers on board future X-ray missions.« less
Double Star Measurements at the Internationale Amateur Sternwarte (IAS) in Namibia in 2008 and 2009
NASA Astrophysics Data System (ADS)
Anton, Rainer
2010-04-01
A 40-cm-Cassegrain telescope in Namibia was used for observing double and multiple systems in the southern sky. Digital images were recorded with a CCD camera at high frame rates via a firewire interface directly in a computer. Measurements of 34 double and multiple systems are presented and compared with literature data. Some noteworthy objects are discussed in more detail.
Recent CCD Images of Hubble's Variable Nebula (NGC 2261)
NASA Astrophysics Data System (ADS)
Meisel, D.; Dykstra, W.; Schulitz, F.
1992-05-01
Four CCD exposures of Hubble's Variable Nebula were taken with the RIT Kodak KF-4200 array using the 0.6m Hawaii telescope at Mauna Kea. The field of view was 5' x 7' of arc with a resolution of 0.3" per pixel. The effective wavelengths were v 5300A, r 6200A, i 8000A and ii 9000A. Preliminary image processing has been done on Macintosh IIfxs and LCs using NIH Image1.44b20 and has revealed considerable detail in the dust cloud, but no obvious obscuration features as seen at past epochs. Final image processing is continuing on Sun workstations using IRAF and SAO Image. Differences of structure between the wavelength bands and comparisons between images at other epochs, CO maps, and polarimetry will be discussed.
CCD Astrometric Measurements of WDS 08167+4053 Using the iTelescope Network
NASA Astrophysics Data System (ADS)
Riley, Bill; Li, Dewei; Li, Junyao; Dennis, Aren; Boyce, Grady; Boyce, Pat
2016-10-01
Separations and position angle astrometric measurements were made of the multiple star system WDS 08167+4053 AB, AC, and BC components. Our measurements compared favorably with historical measurements from the United States Naval Observatory Washington Double Star Catalog, confirming the trend.
Managed pollinator CAP Coordinated Agricultural Project
USDA-ARS?s Scientific Manuscript database
Scientists are looking at the root cause of the Colony Collapse Disorder (CCD) syndrome; searching for new diseases, harmful chemicals or a combination of these factors which could inflict stress on bee colonies pushing them over the edge for recovery. Among multiple suspects identified so far, bee...
Detect Nosema parasite in time
USDA-ARS?s Scientific Manuscript database
Scientists are looking at the root cause of the Colony Collapse Disorder (CCD) syndrome, searching for new diseases, harmful chemicals or a combination of these factors which could inflict stress on bee colonies pushing them over the edge for recovery. Among multiple suspects identified so far, bee ...
A fast double shutter for CCD-based metrology
NASA Astrophysics Data System (ADS)
Geisler, R.
2017-02-01
Image based metrology such as Particle Image Velocimetry (PIV) depends on the comparison of two images of an object taken in fast succession. Cameras for these applications provide the so-called `double shutter' mode: One frame is captured with a short exposure time and in direct succession a second frame with a long exposure time can be recorded. The difference in the exposure times is typically no problem since illumination is provided by a pulsed light source such as a laser and the measurements are performed in a darkened environment to prevent ambient light from accumulating in the long second exposure time. However, measurements of self-luminous processes (e.g. plasma, combustion ...) as well as experiments in ambient light are difficult to perform and require special equipment (external shutters, highspeed image sensors, multi-sensor systems ...). Unfortunately, all these methods incorporate different drawbacks such as reduced resolution, degraded image quality, decreased light sensitivity or increased susceptibility to decalibration. In the solution presented here, off-the-shelf CCD sensors are used with a special timing to combine neighbouring pixels in a binning-like way. As a result, two frames of short exposure time can be captured in fast succession. They are stored in the on-chip vertical register in a line-interleaved pattern, read out in the common way and separated again by software. The two resultant frames are completely congruent; they expose no insensitive lines or line shifts and thus enable sub-pixel accurate measurements. A third frame can be captured at the full resolution analogue to the double shutter technique. Image based measurement techniques such as PIV can benefit from this mode when applied in bright environments. The third frame is useful e.g. for acceleration measurements or for particle tracking applications.
Astronomical Association of Queensland Program of Measurements of Seven Southern Multiple Stars
NASA Astrophysics Data System (ADS)
Jenkinson, Graeme
2016-04-01
This paper presents the results of a mid-2014 program of the Astronomical Association of Queensland of photographic measurements of seven southern multiple stars. The images were obtained using a Meade DSI CCD camera in conjunction with an equatorially mounted 150mm F8 refractor. For each target pair, either a 2x or 5x barlow lens was used as required. Image processing was carried out using Losse's REDUC software.
Enhancing Ground Based Telescope Performance with Image Processing
2013-11-13
driven by the need to detect small faint objects with relatively short integration times to avoid streaking of the satellite image across multiple...the time right before the eclipse. The orbital elements of the satellite were entered into the SST’s tracking system, so that the SST could be...short integration times , thereby avoiding streaking of the satellite image across multiple CCD pixels so that the objects are suitably modeled as point
VizieR Online Data Catalog: BVR photometry of EPIC 211957146 (Sriram+, 2017)
NASA Astrophysics Data System (ADS)
Sriram, K.; Malu, S.; Choi, C. S.; Vivekananda Rao, P.
2017-08-01
Photometric observations of the variable EPIC 211957146 in the R band were taken using the IUCAA-Girawali Observatory (IGO) 2m telescope from 2015 February 5-22, for 5 nights (specifications of IGO 2m telescope CCD are as discussed in Sriram et al. 2016AJ....151...69S). An exposure time of 20-30s was given for imaging. B and V band observations were taken from the JCBT 1.3m telescope at Vainu Bappu Observatory (VBO) during 2016 February 3-8 and 2016 March 25-April 3 for a total of 7 nights. The JCBT 1.3m DFM telescope at VBO uses a 2K*4K UKATC CCD having a gain of 0.745e-/ADU and a read out noise of 4.2e-. The plate scale is 0.3arcsec/pixel resulting in an image of 10'*20' and images of the source in the B and V bands were taken with an integration time of 120s. Differential photometry was performed on the variable, with the comparison and check stars (of similar brightness) lying close to the variable. This source was also observed by the Kepler K2 mission Campaign 5, and the data were acquired from the MAST portal and the NASA Exoplanet Archive. K2 campaign 5 monitored the sky for a duration of ~74days and was fixed upon a single boresight position of 08h40m38s, +16°49'47'' starting from 2015 April 27 to July 10. Spectroscopic observation of the variable was performed during the nights of 2016 January 29-30 using the 2m Himalaya Chandra Telescope (HCT, IAO) equipped with the Himalaya Faint Object Spectrograph Camera (HFOSC) having a 2K*4K CCD. Spectra were obtained with an exposure time of 1800-2700s for both variable and spectrophotometric standard stars (BD+08 2015). A few spectra were also taken on 2016 February 1 using the Optomechanics Research spectrograph mounted on the 2.3m Vainu Bappu Telescope using a 1K*1K CCD. A 600lines/mm grating spanning a wavelength range of 2000-8000Å with a dispersion of 2.6Å/pixel and a resolution of ~5.3Å was used. The same spectrophotometric standard as before was used for observation, and an exposure time of 2700s was given to both the variable and the standard. (2 data files).
Time-resolved imaging of the plasma development in a triggered vacuum switch
NASA Astrophysics Data System (ADS)
Park, Wung-Hoa; Kim, Moo-Sang; Son, Yoon-Kyoo; Frank, Klaus; Lee, Byung-Joon; Ackerman, Thilo; Iberler, Marcus
2017-12-01
Triggered vacuum switches (TVS) are particularly used in pulsed power technology as closing switches for high voltages and high charge transfer. A non-sealed-off prototype was designed with a side-on quartz window to investigate the evolution of the trigger discharge into the main discharge. The image acquisition was done with a fast CCD camera PI-MAX2 from Princeton Instruments. The CCD camera has a maximum exposure time of 2 ns. The electrode configuration of the prototype is a conventional six-rod gap type, a capacitor bank with C = 16.63 μF, which corresponds at 20 kV charging voltage to a total stored charge of 0.3 C or a total energy of 3.3 kJ. The peak current is 88 kA. According to the tremendously highly different light intensities during the trigger and main discharge, the complete discharge is split into three phases: a trigger breakdown phase, an intermediate phase and a main discharge phase. The CCD camera images of the first phase show instabilities of the trigger breakdown, in phase 2 three different discharge modes are observed. After the first current maximum the discharge behavior is reproducible.
Fireball Observations in Visible and Sodium Bands
NASA Astrophysics Data System (ADS)
Fletcher, Sandra
On November 17th at 1:32am MST, a large Leonid fireball was simultaneously imaged by two experiments, a visible band CCD camera and a 590nm filtered band equi-angle fisheye and telecentric lens assembly. The visible band camera, ROTSE (Robotic Optical Transient Search Experiment) is a two by two f/1.9 telephoto lens array with 2k x2k Thompson CCD and is located at 35.87 N, 106.25 W at an altitude of 2115m. One-minute exposures along the radiant were taken of the event for 30 minutes after the initial explosion. The sodium band experiment was located at 35.29 N,106.46 W at an altitude of 1860m. It took ninety second exposures and captured several events throughout the night. Triangulation from two New Mexico sites resulted in an altitude of 83km over Wagon Mound, NM. Two observers present at the ROTSE site saw a green flash and a persistent glow up to seven minutes after the explosion. Cataloging of all sodium trails for comparison with lidar and infrasonic measurements is in progress. The raw data from both experiments and the atmospheric chemistry interpretation of them will be presented.
Establishing imaging sensor specifications for digital still cameras
NASA Astrophysics Data System (ADS)
Kriss, Michael A.
2007-02-01
Digital Still Cameras, DSCs, have now displaced conventional still cameras in most markets. The heart of a DSC is thought to be the imaging sensor, be it Full Frame CCD, and Interline CCD, a CMOS sensor or the newer Foveon buried photodiode sensors. There is a strong tendency by consumers to consider only the number of mega-pixels in a camera and not to consider the overall performance of the imaging system, including sharpness, artifact control, noise, color reproduction, exposure latitude and dynamic range. This paper will provide a systematic method to characterize the physical requirements of an imaging sensor and supporting system components based on the desired usage. The analysis is based on two software programs that determine the "sharpness", potential for artifacts, sensor "photographic speed", dynamic range and exposure latitude based on the physical nature of the imaging optics, sensor characteristics (including size of pixels, sensor architecture, noise characteristics, surface states that cause dark current, quantum efficiency, effective MTF, and the intrinsic full well capacity in terms of electrons per square centimeter). Examples will be given for consumer, pro-consumer, and professional camera systems. Where possible, these results will be compared to imaging system currently on the market.
Managed pollinator CAP coordinated agricultural project: detecting Nosema in time
USDA-ARS?s Scientific Manuscript database
Scientists are looking at the root cause of the Colony Collapse Disorder (CCD) syndrome by searching for new diseases, harmful chemicals or a combination of these factors which could inflict stress on bee colonies pushing them over the edge for recovery. Among multiple suspects identified so far, be...
Experimental research on femto-second laser damaging array CCD cameras
NASA Astrophysics Data System (ADS)
Shao, Junfeng; Guo, Jin; Wang, Ting-feng; Wang, Ming
2013-05-01
Charged Coupled Devices (CCD) are widely used in military and security applications, such as airborne and ship based surveillance, satellite reconnaissance and so on. Homeland security requires effective means to negate these advanced overseeing systems. Researches show that CCD based EO systems can be significantly dazzled or even damaged by high-repetition rate pulsed lasers. Here, we report femto - second laser interaction with CCD camera, which is probable of great importance in future. Femto - second laser is quite fresh new lasers, which has unique characteristics, such as extremely short pulse width (1 fs = 10-15 s), extremely high peak power (1 TW = 1012W), and especially its unique features when interacting with matters. Researches in femto second laser interaction with materials (metals, dielectrics) clearly indicate non-thermal effect dominates the process, which is of vast difference from that of long pulses interaction with matters. Firstly, the damage threshold test are performed with femto second laser acting on the CCD camera. An 800nm, 500μJ, 100fs laser pulse is used to irradiate interline CCD solid-state image sensor in the experiment. In order to focus laser energy onto tiny CCD active cells, an optical system of F/5.6 is used. A Sony production CCDs are chose as typical targets. The damage threshold is evaluated with multiple test data. Point damage, line damage and full array damage were observed when the irradiated pulse energy continuously increase during the experiment. The point damage threshold is found 151.2 mJ/cm2.The line damage threshold is found 508.2 mJ/cm2.The full-array damage threshold is found to be 5.91 J/cm2. Although the phenomenon is almost the same as that of nano laser interaction with CCD, these damage thresholds are substantially lower than that of data obtained from nano second laser interaction with CCD. Then at the same time, the electric features after different degrees of damage are tested with electronic multi meter. The resistance values between clock signal lines are measured. Contrasting the resistance values of the CCD before and after damage, it is found that the resistances decrease significantly between the vertical transfer clock signal lines values. The same results are found between the vertical transfer clock signal line and the earth electrode (ground).At last, the damage position and the damage mechanism were analyzed with above results and SEM morphological experiments. The point damage results in the laser destroying material, which shows no macro electro influence. The line damage is quite different from that of point damage, which shows deeper material corroding effect. More importantly, short circuits are found between vertical clock lines. The full array damage is even more severe than that of line damage starring with SEM, while no obvious different electrical features than that of line damage are found. Further researches are anticipated in femto second laser caused CCD damage mechanism with more advanced tools. This research is valuable in EO countermeasure and/or laser shielding applications.
NASA Astrophysics Data System (ADS)
Golcuk, Kurtulus; Mandair, Gurjit S.; Callender, Andrew F.; Finney, William F.; Sahar, Nadder; Kohn, David H.; Morris, Michael D.
2006-02-01
Background fluorescence can often complicate the use of Raman microspectroscopy in the study of musculoskeletal tissues. Such fluorescence interferences are undesirable as the Raman spectra of matrix and mineral phases can be used to differentiate between normal and pathological or microdamaged bone. Photobleaching with the excitation laser provides a non-invasive method for reducing background fluorescence, enabling 532 nm Raman hyperspectral imaging of bone tissue. The signal acquisition time for a 400 point Raman line image is reduced to 1-4 seconds using electronmultiplying CCD (EMCCD) detector, enabling acquisition of Raman images in less than 10 minutes. Rapid photobleaching depends upon multiple scattering effects in the tissue specimen and is applicable to some, but not all experimental situations.
2014-01-01
and GMOS . Observations were made using a 2′′ slit and grating B600_G5323. Two sets of three 600 s exposures were taken during sky conditions...that the CCD gaps on the GMOS chip could be removed. Three one-second dome flats were taken immediately after each set of exposures and used for flat...procedures as for SCR 1848, whereas the blue spectra were obtained on UT 2011 May 7 at Gemini- South using the same GMOS setup discussed above, but under
Optical Observation, Image-processing, and Detection of Space Debris in Geosynchronous Earth Orbit
NASA Astrophysics Data System (ADS)
Oda, H.; Yanagisawa, T.; Kurosaki, H.; Tagawa, M.
2014-09-01
We report on optical observations and an efficient detection method of space debris in the geosynchronous Earth orbit (GEO). We operate our new Australia Remote Observatory (ARO) where an 18 cm optical telescope with a charged-coupled device (CCD) camera covering a 3.14-degree field of view is used for GEO debris survey, and analyse datasets of successive CCD images using the line detection method (Yanagisawa and Nakajima 2005). In our operation, the exposure time of each CCD image is set to be 3 seconds (or 5 seconds), and the time interval of CCD shutter open is about 4.7 seconds (or 6.7 seconds). In the line detection method, a sufficient number of sample objects are taken from each image based on their shape and intensity, which includes not only faint signals but also background noise (we take 500 sample objects from each image in this paper). Then we search a sequence of sample objects aligning in a straight line in the successive images to exclude the noise sample. We succeed in detecting faint signals (down to about 1.8 sigma of background noise) by applying the line detection method to 18 CCD images. As a result, we detected about 300 GEO objects up to magnitude of 15.5 among 5 nights data. We also calculate orbits of objects detected using the Simplified General Perturbations Satellite Orbit Model 4(SGP4), and identify the objects listed in the two-line-element (TLE) data catalogue publicly provided by the U.S. Strategic Command (USSTRATCOM). We found that a certain amount of our detections are new objects that are not contained in the catalogue. We conclude that our ARO and detection method posse a high efficiency detection of GEO objects despite the use of comparatively-inexpensive observation and analysis system. We also describe the image-processing specialized for the detection of GEO objects (not for usual astronomical objects like stars) in this paper.
Accuracy of Conventional and Digital Radiography in Detecting External Root Resorption
Mesgarani, Abbas; Haghanifar, Sina; Ehsani, Maryam; Yaghub, Samereh Dokhte; Bijani, Ali
2014-01-01
Introduction: External root resorption (ERR) is associated with physiological and pathological dissolution of mineralized tissues by clastic cells and radiography is one of the most important methods in its diagnosis. The aim of this experimental study was to evaluate the accuracy of conventional intraoral radiography (CR) in comparison with digital radiographic techniques, i.e. charge-coupled device (CCD) and photo-stimulable phosphor (PSP) sensors, in detection of ERR. Methods and Materials: This study was performed on 80 extracted human mandibular premolars. After taking separate initial periapical radiographs with CR technique, CCD and PSP sensors, the artificial defects resembling ERR with variable sizes were created in apical half of the mesial, distal and buccal surfaces of the teeth. Ten teeth were used as control samples without any resorption. The radiographs were then repeated with 2 different exposure times and the images were observed by 3 observers. Data were analyzed using SPSS version 17 and chi-squared and Cohen’s Kappa tests with 95% confidence interval (CI=95%). Result: The CCD had the highest percentage of correct assessment compared to the CR and PSP sensors, although the difference was not significant (P=0.39). It was shown that the higher dosage of radiation increases the accuracy of diagnosis; however, it was only significant for CCD sensor (P=0.02). Also, the accuracy of diagnosis increased with the increase in the size of lesion (P=0.001). Conclusion: Statistically significant difference was not observed for accurate detection of ERR by conventional and digital radiographic techniques. PMID:25386202
Follow-up study of children with cerebral coordination disturbance (CCD, Vojta).
Imamura, S; Sakuma, K; Takahashi, T
1983-01-01
713 children (from newborn to 12-month-old) with delayed motor development were carefully examined and classified into normal, very light cerebral coordination disturbance (CCD, Vojta), light CCD, moderate CCD, severe CCD, suspected cerebral palsy (CP) and other diseases at their first visit, and were followed up carefully. Finally, 89.0% of very light CCD, 71.4% of light CCD, 56.0% of moderate CCD and 30.0% of severe CCD developed into normal. 59.5% of moderate CCD and 45.5% of severe CCD among children who were given Vojta's physiotherapy developed into normal. The classification of cases with delayed motor development into very light, light, moderate and severe CCD based on the extent of abnormality in their postural reflexes is useful and well correlated with their prognosis. Treatment by Vojta's method seems to be efficient and helpful for young children with delayed motor development.
PESO - The Python Based Control System of the Ondrejov 2m Telescope
NASA Astrophysics Data System (ADS)
Skoda, P.; Fuchs, J.; Honsa, J.
2005-12-01
Python has been gaining a good reputation and respectability in many areas of software development. We have chosen Python after getting the new CCD detector for the coudé spectrograph of Ondřejov observatory 2m telescope. The VersArray detector from Roper Scientific came only with the closed source library PVCAM of low-level camera control functions for Linux, so we had to write the whole astronomical data acquisition system from scratch and integrate it with the current spectrograph and telescope control systems. The final result of our effort, PESO (Python Exposure System for Ondřejov) is a highly comfortable GUI-based environment allowing the observer to change the spectrograph configuration, choose the detector acquisition mode, select the exposure parameters, and monitor the exposure progress. All of the relevant information from the control computers is written into the FITS headers by the PyFITS module, and the acquired CCD frame is immediately displayed in an SAO DS9 window using XPA calls. The GTK-based front end design was drawn in the Glade visual development tool, giving the shape and position of all widgets in single XML file, which is used in Python by a simple call of the PyGlade module. We describe our experience with the design and implementation of PESO, stressing the easiness of quick changes of the GUI, together with the capability of separate testing of every module using the Python debugger, IPython.
Srivastava, Kshama; Soin, Seepika; Sapra, B K; Ratna, P; Datta, D
2017-11-01
The occupational exposure incurred by the radiation workers due to the external radiation is estimated using personal dosemeter placed on the human body during the monitoring period. In certain situations, it is required to determine whether the dosemeter alone was exposed accidentally/intentionally in radiation field (static exposure) or was exposed while being worn by a worker moving in his workplace (dynamic exposure). The present thermoluminscent (TL) based personnel monitoring systems are not capable of distinguishing between the above stated (static and dynamic) exposure conditions. The feasibility of a new methodology developed using the charge coupled device based imaging technique for identification of the static/dynamic exposure of CaSO4:Dy based TL detectors for low energy photons has been investigated. The techniques for the qualitative and the quantitative assessments of the exposure conditions are presented in this paper. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
VizieR Online Data Catalog: Properties of late M-dwarfs (Janson+, 2014)
NASA Astrophysics Data System (ADS)
Janson, M.; Bergfors, C.; Brandner, W.; Kudryavtseva, N.; Hormuth, F.; Hippler, S.; Henning, T.
2017-03-01
The targets in this study were selected from the Lepine & Gaidos (2011, J/AJ/142/138) sample, where stars with a spectral type (SpT) estimate of M5 or later were selected if they were sufficiently bright (J <= 10.0 mag) and sufficiently far north (>-15°) to be meaningfully observed with AstraLux Norte. In total, this gave an input sample of 408 potential targets, of which 286 were actually observed. All observations in this program were acquired with the AstraLux Norte camera on the 2.2 m telescope at Calar Alto in Spain. The 2.2 m telescope is on an equatorial mount. AstraLux uses an Andor DV887-UVB camera head equipped with a thinned, back-illuminated, electron-multiplying 512 x 512 pixel monolithic CCD. The CCD is equipped with two readout registers, one for conventional readout, and one 536 stage electron multiplication register. Each of the two registers comes with its own output amplifier. All Lucky Imaging data were obtained using the electron multiplication mode, and the associated output amplifier. (3 data files).
Multiple capillary biochemical analyzer with barrier member
Dovichi, N.J.; Zhang, J.Z.
1996-10-22
A multiple capillary biochemical analyzer is disclosed for sequencing DNA and performing other analyses, in which a set of capillaries extends from wells in a microtiter plate into a cuvette. In the cuvette the capillaries are held on fixed closely spaced centers by passing through a sandwich construction having a pair of metal shims which squeeze between them a rubber gasket, forming a leak proof seal for an interior chamber in which the capillary ends are positioned. Sheath fluid enters the chamber and entrains filament sample streams from the capillaries. The filament sample streams, and sheath fluid, flow through aligned holes in a barrier member spaced close to the capillary ends, into a collection chamber having a lower glass window. The filament streams are illuminated above the barrier member by a laser, causing them to fluoresce. The fluorescence is viewed end-on by a CCD camera chip located below the glass window. The arrangement ensures an equal optical path length from all fluorescing spots to the CCD chip and also blocks scattered fluorescence illumination, providing more uniform results and an improved signal-to-noise ratio. 12 figs.
Multiple capillary biochemical analyzer with barrier member
Dovichi, Norman J.; Zhang, Jian Z.
1996-01-01
A multiple capillary biochemical analyzer for sequencing DNA and performing other analyses, in which a set of capillaries extends from wells in a microtiter plate into a cuvette. In the cuvette the capillaries are held on fixed closely spaced centers by passing through a sandwich construction having a pair of metal shims which squeeze between them a rubber gasket, forming a leak proof seal for an interior chamber in which the capillary ends are positioned. Sheath fluid enters the chamber and entrains filament sample streams from the capillaries. The filament sample streams, and sheath fluid, flow through aligned holes in a barrier member spaced close to the capillary ends, into a collection chamber having a lower glass window. The filament streams are illuminated above the barrier member by a laser, causing them to fluoresce. The fluorescence is viewed end-on by a CCD camera chip located below the glass window. The arrangement ensures an equal optical path length from all fluorescing spots to the CCD chip and also blocks scattered fluorescence illumination, providing more uniform results and an improved signal to noise ratio.
Ultrafast Imaging using Spectral Resonance Modulation
NASA Astrophysics Data System (ADS)
Huang, Eric; Ma, Qian; Liu, Zhaowei
2016-04-01
CCD cameras are ubiquitous in research labs, industry, and hospitals for a huge variety of applications, but there are many dynamic processes in nature that unfold too quickly to be captured. Although tradeoffs can be made between exposure time, sensitivity, and area of interest, ultimately the speed limit of a CCD camera is constrained by the electronic readout rate of the sensors. One potential way to improve the imaging speed is with compressive sensing (CS), a technique that allows for a reduction in the number of measurements needed to record an image. However, most CS imaging methods require spatial light modulators (SLMs), which are subject to mechanical speed limitations. Here, we demonstrate an etalon array based SLM without any moving elements that is unconstrained by either mechanical or electronic speed limitations. This novel spectral resonance modulator (SRM) shows great potential in an ultrafast compressive single pixel camera.
VizieR Online Data Catalog: AQ Boo VRI differential light curves (Wang+, 2016)
NASA Astrophysics Data System (ADS)
Wang, S.; Zhang, L.; Pi, Q.; Han, X. L.; Zhang, X.; Lu, H.; Wang, D.; Li, T.
2016-11-01
On March 22 and April 19 in 2014, we observed AQ Boo with the 60cm telescope at Xinglong Station of the National Astronomical Observatories of China (NAOC). The CCD camera on this telescope has a resolution of 1024 x 1024 pixels and its corresponding field of view is 17'x17' (Yang, 2013NewA...25..109Y). The other three days of data were obtained using the 1-m telescope at Yunnan Observatory of Chinese Academy of Sciences, on January 20, 21 and February 28 in 2015. The CCD camera on this telescope has a resolution of 2048x2048 pixels and its corresponding field of view is 7.3'x7.3'. Bessel VRI filters were used. The exposure times are 100-170s, 50-100s and 50-80s in the V, R, I bands, respectively. (1 data file).
Design and realization of an AEC&AGC system for the CCD aerial camera
NASA Astrophysics Data System (ADS)
Liu, Hai ying; Feng, Bing; Wang, Peng; Li, Yan; Wei, Hao yun
2015-08-01
An AEC and AGC(Automatic Exposure Control and Automatic Gain Control) system was designed for a CCD aerial camera with fixed aperture and electronic shutter. The normal AEC and AGE algorithm is not suitable to the aerial camera since the camera always takes high-resolution photographs in high-speed moving. The AEC and AGE system adjusts electronic shutter and camera gain automatically according to the target brightness and the moving speed of the aircraft. An automatic Gamma correction is used before the image is output so that the image is better for watching and analyzing by human eyes. The AEC and AGC system could avoid underexposure, overexposure, or image blurring caused by fast moving or environment vibration. A series of tests proved that the system meet the requirements of the camera system with its fast adjusting speed, high adaptability, high reliability in severe complex environment.
Easily Transported CCD Systems for Use in Astronomy Labs
NASA Astrophysics Data System (ADS)
Meisel, D.
1992-12-01
Relatively inexpensive CCD cameras and portable computers are now easily obtained as commercially available products. I will describe a prototype system that can be used by introductory astronomy students, even urban enviroments, to obtain useful observations of the night sky. It is based on the ST-4 CCDs made by Santa Barbara Instruments Group and Macintosh Powerbook145 computers. Students take outdoor images directly from the college campus, bring the exposures back into the lab and download the images into our networked server. These stored images can then be processed (at a later time) using a variety of image processing programs including a new astronomical version of the popular "freeware" NIH Image package that is currently under development at Geneseo. The prototype of this system will be demonstrated and available for hands-on use during the meeting. This work is supported by NSF ILI Demonstration Grant USE9250493 and Grants from SUNY-GENESEO.
SkyProbe, monitoring the absolute atmospheric transmission in the optical
NASA Astrophysics Data System (ADS)
Cuillandre, Jean-charles; Magnier, Eugene; Mahoney, William
2011-03-01
Mauna Kea is known for its pristine seeing conditions, but sky transparency can be an issue for science operations since 25% of the night are not photometric, mostly due to high-altitude cirrus. Since 2001, the original single-channel SkyProbe has gathered one exposure every minute during each observing night using a small CCD camera with a very wide field of view (35 sq. deg.) encompassing the region pointed by the telescope for science operations, and exposures long enough (40 seconds) to capture at least 100 stars of Hipparcos' Tychos catalog at high galactic latitudes (and up to 600 stars at low galactic latitudes). A key advantage of SkyProbe over direct thermal infrared imaging detection of clouds, is that it allows an accurate absolute measurement, within 5%, of the true atmospheric absorption by clouds affecting the data being gathered by the telescope's main science instrument. This system has proven crucial for decision making in the CFHT queued service observing (QSO), representing today 80% of the telescope time: science exposures taken in non-photometric conditions are automatically registered for being re-observed later on (at 1/10th of the original exposure time per pointing in the observed filters) to ensure a proper final absolute photometric calibration. The new dual color system (simultaneous B&V bands) will allow a better characterization of the sky properties atop Mauna Kea and will enable a better detection of the thinner cirrus (absorption down to 0.02 mag., i.e. 2%). SkyProbe is operated within the Elixir pipeline, a collection of tools used for handling the CFHT CCD mosaics (CFH12K and MegaCam), from data pre-processing to astrometric and photometric calibration.
Astrometric Calibration and Performance of the Dark Energy Camera
Bernstein, G. M.; Armstrong, R.; Plazas, A. A.; ...
2017-05-30
We characterize the ability of the Dark Energy Camera (DECam) to perform relative astrometry across its 500 Mpix, 3more » $deg^2$ science field of view, and across 4 years of operation. This is done using internal comparisons of $~ 4 x 10^7$ measurements of high-S/N stellar images obtained in repeat visits to fields of moderate stellar density, with the telescope dithered to move the sources around the array. An empirical astrometric model includes terms for: optical distortions; stray electric fields in the CCD detectors; chromatic terms in the instrumental and atmospheric optics; shifts in CCD relative positions of up to $$\\approx 10 \\mu m$$ when the DECam temperature cycles; and low-order distortions to each exposure from changes in atmospheric refraction and telescope alignment. Errors in this astrometric model are dominated by stochastic variations with typical amplitudes of 10-30 mas (in a 30 s exposure) and $$5^{\\prime}-10^{\\prime}$$ arcmin coherence length, plausibly attributed to Kolmogorov-spectrum atmospheric turbulence. The size of these atmospheric distortions is not closely related to the seeing. Given an astrometric reference catalog at density $$\\approx 0.7$$ $$arcmin^{-2}$$, e.g. from Gaia, the typical atmospheric distortions can be interpolated to $$\\approx$$ 7 mas RMS accuracy (for 30 s exposures) with $$1^{\\prime}$$ arcmin coherence length for residual errors. Remaining detectable error contributors are 2-4 mas RMS from unmodelled stray electric fields in the devices, and another 2-4 mas RMS from focal plane shifts between camera thermal cycles. Thus the astrometric solution for a single DECam exposure is accurate to 3-6 mas ( $$\\approx$$ 0.02 pixels, or $$\\approx$$ 300 nm) on the focal plane, plus the stochastic atmospheric distortion.« less
The cD galaxy in Abell cluster 1775
NASA Technical Reports Server (NTRS)
Hayes, J. J. E.; Bhattacharya, B.
1990-01-01
Over the last 20 years, a number of workers have studied the multiple nuclei cD galaxy in the rich Abell cluster 1775, trying to discover its nature. In all the cases though, very little has been published concerning its morphology. The majority of arguments about the nature of this object have been based on the relative radial velocities of the 2 components with each other and with the other galaxies in the cluster, or its radio morphology. Very little work has been done on the optical morphology. To rectify that lack of data, the authors have obtained charge coupled device (CCD) images of the cD. The authors find from the CCD data that the cD is unlikely to be a bound object and that there is strong evidence for a collision.
Rethinking CCD's Significance in Estimating Late Neogene Whole Ocean Carbonate Budget
NASA Astrophysics Data System (ADS)
Si, W.; Rosenthal, Y.
2017-12-01
The global averaged calcite compensation depth (CCD) record is conventionally used to reconstruct two correlatable parameters of the carbonate system - the alkalinity budget of the ocean and/or the saturation state of the ocean. Accordingly, the available CCD reconstructions have been interpreted to suggest either relative stable (Pearson and Palmer, 2000) or increased alkalinity of the ocean over the past 15 Ma (Tyrrell and Zeebe, 2004; Pälike et al., 2012). However, CCD alone is insufficient to constrain the carbonate system because the weathering flux of alkalinity into the ocean is not only balanced by CaCO3 dissolution on the seafloor but also by the biologic production in the euphotic zone and, the CCD records cannot be readily interpreted as changes in either process. Here, we present evidence of the co-evolution of surface CaCO3 production and deepsea dissolution through the late Neogene. By examining separately the mass accumulation rates (MAR) of coccoliths, planktonic foraminifera, and quantifying dissolution (using a proxy revised from Broecker et al., 1999) in seventeen deepsea cores from multiple depth-transects, we find that 1) MAR of dissolution-resistant coccoliths was substantially higher in the mid Miocene and declining on a global scale towards the present; 2) unlike coccoliths, MAR of planktonic foraminifera, shows no apparent secular trend through that time; 3) the revised dissolution index, shows significantly improved preservation of planktonic foraminiferal shells over that time, particularly at intermediate water depth and exhibits close association between changes in preservation with key climatic events. Our new records have two immediate implications. First, the substantially weakened pelagic biogenic carbonate production from mid Miocene to present alone could account for the improved preservation of deepsea carbonates without calling for a scenario of increased weathering input. Second, with the constrain of global averaged CCD records, the net accumulation of pelagic carbonate has declined over the course of late Neogene. Hence, the weathering alkalinity input should have decreased since 15 Ma, as oppose to the weathering hypothesis (Raymo et al., 1988).
CCD Astrometric Measurements of WDS 04155+0611
NASA Astrophysics Data System (ADS)
Cao, Zhixin; Li, Junyao; Li, Jeff; Qu, Steve; Fene, Michael; Boyce, Grady; Boyce, Pat
2016-01-01
Twenty-two separations and position angle astrometric measurements were made of the multiple star system WDS 04155+0611. This system includes the pairs STTA 45 AB, H 6 98 AC, H 6 98 CD, and STU 18 CE. All measurements were compared with historical measurements from the Washington Double Star Catalog. Our astrometric results compare favorably with other recent observations.
IDSAC-IUCAA digital sampler array controller
NASA Astrophysics Data System (ADS)
Chattopadhyay, Sabyasachi; Chordia, Pravin; Ramaprakash, A. N.; Burse, Mahesh P.; Joshi, Bhushan; Chillal, Kalpesh
2016-07-01
In order to run the large format detector arrays and mosaics that are required by most astronomical instruments, readout electronic controllers are required which can process multiple CCD outputs simultaneously at high speeds and low noise levels. These CCD controllers need to be modular and configurable, should be able to run multiple detector types to cater to a wide variety of requirements. IUCAA Digital Sampler Array Controller (IDSAC), is a generic CCD Controller based on a fully scalable architecture which is adequately flexible and powerful enough to control a wide variety of detectors used in ground based astronomy. The controller has a modular backplane architecture that consists of Single Board Controller Cards (SBCs) and can control up to 5 CCDs (mosaic or independent). Each Single Board Controller (SBC) has all the resources to a run Single large format CCD having up to four outputs. All SBCs are identical and are easily interchangeable without needing any reconfiguration. A four channel video processor on each SBC can process up to four output CCDs with or without dummy outputs at 0.5 Megapixels/Sec/Channel with 16 bit resolution. Each SBC has a USB 2.0 interface which can be connected to a host computer via optional USB to Fibre converters. The SBC uses a reconfigurable hardware (FPGA) as a Master Controller. IDSAC offers Digital Correlated Double Sampling (DCDS) to eliminate thermal kTC noise. CDS performed in Digital domain (DCDS) has several advantages over its analog counterpart, such as - less electronics, faster readout and easier post processing. It is also flexible with sampling rate and pixel throughput while maintaining the core circuit topology intact. Noise characterization of the IDSAC CDS signal chain has been performed by analytical modelling and practical measurements. Various types of noise such as white, pink, power supply, bias etc. has been considered while creating an analytical noise model tool to predict noise of a controller system like IDSAC. Several tests are performed to measure the actual noise of IDSAC. The theoretical calculation matches very well with practical measurements within 10% accuracy.
Soft x-ray pinhole imaging diagnostics for compact toroid plasmas
NASA Astrophysics Data System (ADS)
Crawford, E. A.; Taggart, D. P.; Bailey, A. D., III
1990-10-01
Soft x-ray pinhole imaging has recently become established as a valuable diagnostic for visualization of field reversed configuration (FRC) plasmas in the TRX-2, FRX-C/LSM devices. Gated MCP image converter devices with CsI cathodes and Be filters with a peak response around 11 nm wavelength are used for exposure durations ranging from a few tenths up to several microseconds. Results of experiments with single and Chevron channel plates are discussed along with estimates of linear exposure limitations with both film and CCD cameras as recording media. Plans for multiframe devices on the FRX-C/LSM and the LSX devices are also discussed.
Cognitive dysfunction in naturally occurring canine idiopathic epilepsy.
Packer, Rowena M A; McGreevy, Paul D; Salvin, Hannah E; Valenzuela, Michael J; Chaplin, Chloe M; Volk, Holger A
2018-01-01
Globally, epilepsy is a common serious brain disorder. In addition to seizure activity, epilepsy is associated with cognitive impairments including static cognitive impairments present at onset, progressive seizure-induced impairments and co-morbid dementia. Epilepsy occurs naturally in domestic dogs but its impact on canine cognition has yet to be studied, despite canine cognitive dysfunction (CCD) recognised as a spontaneous model of dementia. Here we use data from a psychometrically validated tool, the canine cognitive dysfunction rating (CCDR) scale, to compare cognitive dysfunction in dogs diagnosed with idiopathic epilepsy (IE) with controls while accounting for age. An online cross-sectional study resulted in a sample of 4051 dogs, of which n = 286 had been diagnosed with IE. Four factors were significantly associated with a diagnosis of CCD (above the diagnostic cut-off of CCDR ≥50): (i) epilepsy diagnosis: dogs with epilepsy were at higher risk; (ii) age: older dogs were at higher risk; (iii) weight: lighter dogs (kg) were at higher risk; (iv) training history: dogs with more exposure to training activities were at lower risk. Impairments in memory were most common in dogs with IE, but progression of impairments was not observed compared to controls. A significant interaction between epilepsy and age was identified, with IE dogs exhibiting a higher risk of CCD at a young age, while control dogs followed the expected pattern of low-risk throughout middle age, with risk increasing exponentially in geriatric years. Within the IE sub-population, dogs with a history of cluster seizures and high seizure frequency had higher CCDR scores. The age of onset, nature and progression of cognitive impairment in the current IE dogs appear divergent from those classically seen in CCD. Longitudinal monitoring of cognitive function from seizure onset is required to further characterise these impairments.
VizieR Online Data Catalog: Optical & Spitzer photometry in IC 1805 (Sung+, 2017)
NASA Astrophysics Data System (ADS)
Sung, H.; Bessell, M. S.; Chun, M.-Y.; Yi, J.; Naze, Y.; Lim, B.; Karimov, R.; Rauw, G.; Park, B.-G.; Hur, H.
2017-06-01
For a study of the IMF and the star-formation history of the young open cluster IC 1805, we obtained deep wide-field VRI and Hα images of IC 1805 using the CFH12K mosaic CCD camera of the CFHT on 2002 January 6 and 7. We also observed several regions in IC 1805, for a study of the reddening and massive star content, using the SITe 2000x800 CCD (Maidanak 2k CCD) and standard UBVRI filters of the AZT-22 1.5m telescope at the Maidanak Astronomical Observatory in Uzbekistan on 2003 August 18 and 2004 december 25,30. Later, we obtained additional images of the central region of IC 1805 with the Fairchild 486 CCD (SNUCam) and UBVI and Hα filters of the AZT-22 telescope on 2007 October 7 and 2009 January 19. The Spitzer mapping observations were performed on 2006 September 20 under program ID 20052 (PI: S. Wolff). For complete photometry of stars in the CFH12K FOV in 3.6 and 4.5um, we also downloaded and reduced the GLIMPSE360 data (AOR: 38753280, 38763264, 38769408, 38799104, 38798592, 38784512, PI: B. A. Whitney). MIPS scans of IC 1805 were obtained on 2005 August 31 and 2005 September 2 (PID 3234, PI: J. S. Greeves). The Chandra X-ray Observatory Observations of IC 1805 (ObsID: 7033, PI: L. Townley) were made on 2006 November 25. The total exposure time was about 79ks. The properties of 647 X-ray sources were published in Townsley+ (2014,J/ApJS/213/1). We searched for the optical and MIR counterparts of these X-ray sources with a matching radius of up to 1.5". (4 data files).
Cognitive dysfunction in naturally occurring canine idiopathic epilepsy
McGreevy, Paul D.; Salvin, Hannah E.; Valenzuela, Michael J.; Chaplin, Chloe M.; Volk, Holger A.
2018-01-01
Globally, epilepsy is a common serious brain disorder. In addition to seizure activity, epilepsy is associated with cognitive impairments including static cognitive impairments present at onset, progressive seizure-induced impairments and co-morbid dementia. Epilepsy occurs naturally in domestic dogs but its impact on canine cognition has yet to be studied, despite canine cognitive dysfunction (CCD) recognised as a spontaneous model of dementia. Here we use data from a psychometrically validated tool, the canine cognitive dysfunction rating (CCDR) scale, to compare cognitive dysfunction in dogs diagnosed with idiopathic epilepsy (IE) with controls while accounting for age. An online cross-sectional study resulted in a sample of 4051 dogs, of which n = 286 had been diagnosed with IE. Four factors were significantly associated with a diagnosis of CCD (above the diagnostic cut-off of CCDR ≥50): (i) epilepsy diagnosis: dogs with epilepsy were at higher risk; (ii) age: older dogs were at higher risk; (iii) weight: lighter dogs (kg) were at higher risk; (iv) training history: dogs with more exposure to training activities were at lower risk. Impairments in memory were most common in dogs with IE, but progression of impairments was not observed compared to controls. A significant interaction between epilepsy and age was identified, with IE dogs exhibiting a higher risk of CCD at a young age, while control dogs followed the expected pattern of low-risk throughout middle age, with risk increasing exponentially in geriatric years. Within the IE sub-population, dogs with a history of cluster seizures and high seizure frequency had higher CCDR scores. The age of onset, nature and progression of cognitive impairment in the current IE dogs appear divergent from those classically seen in CCD. Longitudinal monitoring of cognitive function from seizure onset is required to further characterise these impairments. PMID:29420639
Progress In Ground Based Mercury's Imaging
NASA Astrophysics Data System (ADS)
Ksanfomality, L.
The reduction of an exposure time improves considerably the resolution of the images of astronomical objects, which usually equals 1.0"-1.5"?for telescopes of a moderate diameter. A poor resolution is determined specifically by the atmospheric instability. A considerable reduction of the exposure became possible only with the advent of ef- fective CCD receivers. Certainly, the reduction of exposure does not eliminate distor- tions, though it can eliminate the image blurring. Nevertheless, it is possible to select the images with small distortions from a number of images. This study using the short exposure method for observations of the planet Mercury started in 1998 (Ksanfomal- ity, 1998). A similar study of Mercury using ground based technique, was fulfilled by J.Warell (Astronomical Observatory Uppsala, Sweden) and S.S.Limaye (University of Wisconsin-Madison, USA). J. Warell started his work as early as 1995 (Warell and Limaye, 2001). Later J.Baumgardner, M.Mendello and J.K.Wilson (2000) succeeded obtaining an image of a portion of Mercury's surface not covered by the Mariner- 10 imaging. They used a CCD camera, continuously operating with frequency 30 frames/sec and choose the best of them for a compilation. Due to the low planet's orbit the possible duration of the ground-based observations of Mercury is extremely limited. Nevertheless the new results are really promising and can be a means for obtaining new information on the planet; it may be of importance for new missions to Mercury that are now in progress both by NASA (the Messenger project) and by the European Space Agency (the BepiColombo project). Within the framework of the Mercury investigations carried out at the Institute for Space Research, Russian Academy of Sciences, on December 1-3, 1999, and November 1-10, 2001, observa- tions of the planet Mercury were carried out at the Abastumany Astrophysical Obser- vatory (Republic of Georgia), by the short exposure method using a charge-coupled device (CCD) camera. A great advantage of the observations at this Observatory was its considerable height above sea level (about 1700 m), which is important for obser- vations at large zenith distances.The AZT-11 telescope (D = 1.25 m, the Cassegrain focus F = 16 m) was used as a long-focus instrument. Due to a random fortunate co- incidence, the phase and position of the planet happened to be virtually the same as 1 in 1974, when Mercury was observed from the Mariner-10 spacecraft. Exposures as short as 3 ms and up to 70 ms were used. The atmospheric condition on November 3rd for about 45 min got unusually clear, and about 300 of electronic images of different quality were gathered. Using a sophisticated technique processing of observationally independent data rows resulted in many compositional electronic images with a num- ber of small features, never seen before and repeating times and again, which could be successfully compared the Mariner-10 mosaic. A set of the images is presented. 2
NASA Astrophysics Data System (ADS)
Demro, James C.; Hartshorne, Richard; Woody, Loren M.; Levine, Peter A.; Tower, John R.
1995-06-01
The next generation Wedge Imaging Spectrometer (WIS) instruments currently in integration at Hughes SBRD incorporate advanced features to increase operation flexibility for remotely sensed hyperspectral imagery collection and use. These features include: a) multiple linear wedge filters to tailor the spectral bands to the scene phenomenology; b) simple, replaceable fore-optics to allow different spatial resolutions and coverages; c) data acquisition system (DAS) that collects the full data stream simultaneously from both WIS instruments (VNIR and SWIR/MWIR), stores the data in a RAID storage, and provides for down-loading of the data to MO disks; the WIS DAS also allows selection of the spectral band sets to be stored; d) high-performance VNIR camera subsystem based upon a 512 X 512 CCD area array and associated electronics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buts, Lieven; De Jonge, Natalie; Loris, Remy, E-mail: reloris@vub.ac.be
2005-10-01
The CcdA C-terminal domain was crystallized in complex with CcdB in two crystal forms that diffract to beyond 2.0 Å resolution. CcdA and CcdB are the antidote and toxin of the ccd addiction module of Escherichia coli plasmid F. The CcdA C-terminal domain (CcdA{sub C36}; 36 amino acids) was crystallized in complex with CcdB (dimer of 2 × 101 amino acids) in three different crystal forms, two of which diffract to high resolution. Form II belongs to space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 37.6, b = 60.5, c = 83.8 Å and diffracts to 1.8more » Å resolution. Form III belongs to space group P2{sub 1}, with unit-cell parameters a = 41.0, b = 37.9, c = 69.6 Å, β = 96.9°, and diffracts to 1.9 Å resolution.« less
ACS Internal CTE Monitor and Short Darks
NASA Astrophysics Data System (ADS)
Ogaz, Sara
2013-10-01
This is a continuation of Program 13156 and is to be executed once a cycle for internal CTE and short darks, respectively.INTERNAL CTE MONITOR:The charge transfer efficiency {CTE} of the ACS CCD detectors will decline as damage due to on-orbit radiation exposure accumulates. This degradation will be monitored once a cycle to determine the useful lifetime of the CCDs. All the data for this program is acquired using internal targets {lamps} only, so all of the exposures should be taken during Earth occultation time {but not during SAA passages}. This program emulates the ACS pre-flight ground calibration and post-launch SMOV testing {program 8948}, so that results from each epoch can be directly compared. Extended Pixel Edge Response {EPER} data will be obtained over a range of signal levels for the Wide Field Channel {WFC}. The signal levels are 125, 500, 1620, 5000, 10000, and 60000 electrons at gain 2.Since Cycle 18, this monitoring program was reduced {compared to 11881} considering that there is also an external CTE monitoring program.SHORT DARKS:To improve the pixel-based CTE model at signals below 10 DN, short dark frames are needed to obtain a statistically useful sample of clean, warm pixel trails. This program obtains a set of dark frames for each of the following exposure times: 66 s {60 s for some subarrays} and 339 s. These short darks and the 1040 s darks obtained from the CCD Daily Monitor will sample warm and hot pixels over logarithmically increasing brightness. Subarray short darks were added in Cycle 19 to study CTE tails in different subarray readout modes.
The impact of radiation damage on photon counting with an EMCCD for the WFIRST-AFTA coronagraph
NASA Astrophysics Data System (ADS)
Bush, Nathan; Hall, David; Holland, Andrew; Burgon, Ross; Murray, Neil; Gow, Jason; Soman, Matthew; Jordan, Douglas; Demers, Richard; Harding, Leon; Hoenk, Michael; Michaels, Darren; Nemati, Bijan; Peddada, Pavani
2015-09-01
WFIRST-AFTA is a 2.4m class NASA observatory designed to address a wide range of science objectives using two complementary scientific payloads. The Wide Field Instrument (WFI) offers Hubble quality imaging over a 0.28 square degree field of view, and will gather NIR statistical data on exoplanets through gravitational microlensing. The second instrument is a high contrast coronagraph that will carry out the direct imaging and spectroscopic analysis of exoplanets, providing a means to probe the structure and composition of planetary systems. The coronagraph instrument is expected to operate in low photon flux for long integration times, meaning all noise sources must be kept to a minimum. In order to satisfy the low noise requirements, the Electron Multiplication (EM)-CCD has been baselined for both the imaging and spectrograph cameras. The EMCCD was selected in comparison with other candidates because of its low effective electronic read noise at sub-electron values with appropriate multiplication gain setting. The presence of other noise sources, however, such as thermal dark signal and Clock Induced Charge (CIC), need to be characterised and mitigated. In addition, operation within a space environment will subject the device to radiation damage that will degrade the Charge Transfer Efficiency (CTE) of the device throughout the mission lifetime. Here we present our latest results from pre- and post-irradiation testing of the e2v CCD201-20 BI EMCCD sensor, baselined for the WFIRST-AFTA coronagraph instrument. A description of the detector technology is presented, alongside considerations for operation within a space environment. The results from a room temperature irradiation are discussed in context with the nominal operating requirements of AFTA-C and future work which entails a cryogenic irradiation of the CCD201-20 is presented.
Soft x-ray imager (SXI) onboard the NeXT satellite
NASA Astrophysics Data System (ADS)
Tsuru, Takeshi Go; Takagi, Shin-Ichiro; Matsumoto, Hironori; Inui, Tatsuya; Ozawa, Midori; Koyama, Katsuji; Tsunemi, Hiroshi; Hayashida, Kiyoshi; Miyata, Emi; Ozawa, Hideki; Touhiguchi, Masakuni; Matsuura, Daisuke; Dotani, Tadayasu; Ozaki, Masanobu; Murakami, Hiroshi; Kohmura, Takayoshi; Kitamoto, Shunji; Awaki, Hisamitsu
2006-06-01
We give overview and the current status of the development of the Soft X-ray Imager (SXI) onboard the NeXT satellite. SXI is an X-ray CCD camera placed at the focal plane detector of the Soft X-ray Telescopes for Imaging (SXT-I) onboard NeXT. The pixel size and the format of the CCD is 24 x 24μm (IA) and 2048 x 2048 x 2 (IA+FS). Currently, we have been developing two types of CCD as candidates for SXI, in parallel. The one is front illumination type CCD with moderate thickness of the depletion layer (70 ~ 100μm) as a baseline plan. The other one is the goal plan, in which we develop back illumination type CCD with a thick depletion layer (200 ~ 300μm). For the baseline plan, we successfully developed the proto model 'CCD-NeXT1' with the pixel size of 12μm x 12μm and the CCD size of 24mm x 48mm. The depletion layer of the CCD has reached 75 ~ 85μm. The goal plan is realized by introduction of a new type of CCD 'P-channel CCD', which collects holes in stead of electrons in the common 'N-channel CCD'. By processing a test model of P-channel CCD we have confirmed high quantum efficiency above 10 keV with an equivalent depletion layer of 300μm. A back illumination type of P-channel CCD with a depletion layer of 200μm with aluminum coating for optical blocking has been also successfully developed. We have been also developing a thermo-electric cooler (TEC) with the function of the mechanically support of the CCD wafer without standoff insulators, for the purpose of the reduction of thermal input to the CCD through the standoff insulators. We have been considering the sensor housing and the onboard electronics for the CCD clocking, readout and digital processing of the frame date.
Linear CCD attitude measurement system based on the identification of the auxiliary array CCD
NASA Astrophysics Data System (ADS)
Hu, Yinghui; Yuan, Feng; Li, Kai; Wang, Yan
2015-10-01
Object to the high precision flying target attitude measurement issues of a large space and large field of view, comparing existing measurement methods, the idea is proposed of using two array CCD to assist in identifying the three linear CCD with multi-cooperative target attitude measurement system, and to address the existing nonlinear system errors and calibration parameters and more problems with nine linear CCD spectroscopic test system of too complicated constraints among camera position caused by excessive. The mathematical model of binocular vision and three linear CCD test system are established, co-spot composition triangle utilize three red LED position light, three points' coordinates are given in advance by Cooperate Measuring Machine, the red LED in the composition of the three sides of a triangle adds three blue LED light points as an auxiliary, so that array CCD is easier to identify three red LED light points, and linear CCD camera is installed of a red filter to filter out the blue LED light points while reducing stray light. Using array CCD to measure the spot, identifying and calculating the spatial coordinates solutions of red LED light points, while utilizing linear CCD to measure three red LED spot for solving linear CCD test system, which can be drawn from 27 solution. Measured with array CCD coordinates auxiliary linear CCD has achieved spot identification, and has solved the difficult problems of multi-objective linear CCD identification. Unique combination of linear CCD imaging features, linear CCD special cylindrical lens system is developed using telecentric optical design, the energy center of the spot position in the depth range of convergence in the direction is perpendicular to the optical axis of the small changes ensuring highprecision image quality, and the entire test system improves spatial object attitude measurement speed and precision.
Adaptive Optics Makes A Research Instrument Out Of A Commercial 30 cm Aperture Telescope
NASA Astrophysics Data System (ADS)
Durig, D. T.
1999-12-01
I recently upgraded my SBIG ST-8 CCD camera with the AO-7 Adaptive Optics unit. This has solved many of the problems with tracking errors and the stability of my telescope mount and allowed me to obtain useful astrometric information on asteroids, comets and supernovae. It is no longer easy to take automated remote images but as long as I am at the observatory, good quality data can be obtained. The AO-7 unit allows me to pick a guide star for the guiding CCD just slightly out of the field of view of the imaging CCD. I am able to guide at the rate of 5 corrections per second with a 13th magnitude guide star. The fastest I have been able to guide is 30 times per second, but there are not usually bright enough stars near the image field to use this rate. When I have to use a dimmer star to guide on, and my rate is as slow as once per two seconds, good results are possible as long as the winds are not too strong. With a focal length of 1775 mm (f/5.75) and 2x2 binning on the CDD I am able to reach at least 18th magnitude objects in a 30 second exposure, but the guiding has to be very good to use these images for astrometry. For objects dimmer than 17th magnitude I normally go to a 2 minute exposure. With this equipment I was the first to observe that a recently discovered object (Comet LINEAR S4) was a comet and not an asteroid as originally reported (see IAUC 7267). I have performed additional astrometric observations on Comets LINEAR S3, S4, T2 and Ferris U1. I have also performed measurements on over a dozen asteroids from the MPC Critical List.
Double Star Measurements at the Internationale Amateur Sternwarte (IAS) in Namibia in 2009
NASA Astrophysics Data System (ADS)
Anton, Rainer
2012-01-01
This paper is a continuation of earlier work published in JDSO in 2010. Using a 40-cm-Cassegrain telescope in Namibia and a fast CCD camera, 87 double and multiple systems were recorded and analyzed with the technique of "lucky imaging". Measurements are compared with literature data. Some noteworthy systems are discussed in more detail.
Large Format CMOS-based Detectors for Diffraction Studies
NASA Astrophysics Data System (ADS)
Thompson, A. C.; Nix, J. C.; Achterkirchen, T. G.; Westbrook, E. M.
2013-03-01
Complementary Metal Oxide Semiconductor (CMOS) devices are rapidly replacing CCD devices in many commercial and medical applications. Recent developments in CMOS fabrication have improved their radiation hardness, device linearity, readout noise and thermal noise, making them suitable for x-ray crystallography detectors. Large-format (e.g. 10 cm × 15 cm) CMOS devices with a pixel size of 100 μm × 100 μm are now becoming available that can be butted together on three sides so that very large area detector can be made with no dead regions. Like CCD systems our CMOS systems use a GdOS:Tb scintillator plate to convert stopping x-rays into visible light which is then transferred with a fiber-optic plate to the sensitive surface of the CMOS sensor. The amount of light per x-ray on the sensor is much higher in the CMOS system than a CCD system because the fiber optic plate is only 3 mm thick while on a CCD system it is highly tapered and much longer. A CMOS sensor is an active pixel matrix such that every pixel is controlled and readout independently of all other pixels. This allows these devices to be readout while the sensor is collecting charge in all the other pixels. For x-ray diffraction detectors this is a major advantage since image frames can be collected continuously at up 20 Hz while the crystal is rotated. A complete diffraction dataset can be collected over five times faster than with CCD systems with lower radiation exposure to the crystal. In addition, since the data is taken fine-phi slice mode the 3D angular position of diffraction peaks is improved. We have developed a cooled 6 sensor CMOS detector with an active area of 28.2 × 29.5 cm with 100 μm × 100 μm pixels and a readout rate of 20 Hz. The detective quantum efficiency exceeds 60% over the range 8-12 keV. One, two and twelve sensor systems are also being developed for a variety of scientific applications. Since the sensors are butt able on three sides, even larger systems could be built at reasonable cost.
2013-01-01
Background In plants, carotenoids serve as the precursors to C13-norisoprenoids, a group of apocarotenoid compounds with diverse biological functions. Enzymatic cleavage of carotenoids catalysed by members of the carotenoid cleavage dioxygenase (CCD) family has been shown to produce a number of industrially important volatile flavour and aroma apocarotenoids including β-ionone, geranylacetone, pseudoionone, α-ionone and 3-hydroxy-β-ionone in a range of plant species. Apocarotenoids contribute to the floral and fruity attributes of many wine cultivars and are thereby, at least partly, responsible for the “varietal character”. Despite their importance in grapes and wine; carotenoid cleavage activity has only been described for VvCCD1 and the mechanism(s) and regulation of carotenoid catabolism remains largely unknown. Results Three grapevine-derived CCD-encoding genes have been isolated and shown to be functional with unique substrate cleavage capacities. Our results demonstrate that the VvCCD4a and VvCCD4b catalyse the cleavage of both linear and cyclic carotenoid substrates. The expression of VvCCD1, VvCCD4a and VvCCD4b was detected in leaf, flower and throughout berry development. VvCCD1 expression was constitutive, whereas VvCCD4a expression was predominant in leaves and VvCCD4b in berries. A transgenic population with a 12-fold range of VvCCD1 expression exhibited a lack of correlation between VvCCD1 expression and carotenoid substrates and/or apocarotenoid products in leaves, providing proof that the in planta function(s) of VvCCD1 in photosynthetically active tissue is distinct from the in vitro activities demonstrated. The isolation and functional characterisation of VvCCD4a and VvCCD4b identify two additional CCDs that are functional in grapevine. Conclusions Taken together, our results indicate that the three CCDs are under various levels of control that include gene expression (spatial and temporal), substrate specificity and compartmentalisation that act individually and/or co-ordinately to maintain carotenoid and volatile apocarotenoid levels in plants. Altering the expression of VvCCD1 in a transgenic grapevine population illustrated the divergence between the in vitro enzyme activity and the in planta activity of this enzyme, thereby contributing to the efforts to understand how enzymatic degradation of carotenoids involved in photosynthesis occurs. The identification and functional characterisation of VvCCD4a and VvCCD4b suggest that these enzymes are primarily responsible for catalysing the cleavage of plastidial carotenoids. PMID:24106789
Improved Underwater Excitation-Emission Matrix Fluorometer
NASA Technical Reports Server (NTRS)
Moore, Casey; daCunha, John; Rhoades, Bruce; Twardowski, Michael
2007-01-01
A compact, high-resolution, two-dimensional excitation-emission matrix fluorometer (EEMF) has been designed and built specifically for use in identifying and measuring the concentrations of organic compounds, including polluting hydrocarbons, in natural underwater settings. Heretofore, most EEMFs have been designed and built for installation in laboratories, where they are used to analyze the contents of samples collected in the field and brought to the laboratories. Because the present EEMF can be operated in the field, it is better suited to measurement of spatially and temporally varying concentrations of substances of interest. In excitation-emission matrix (EEM) fluorometry, fluorescence is excited by irradiating a sample at one or more wavelengths, and the fluorescent emission from the sample is measured at multiple wavelengths. When excitation is provided at only one wavelength, the technique is termed one-dimensional (1D) EEM fluorometry because the resulting matrix of fluorescence emission data (the EEM) contains only one row or column. When excitation is provided at multiple wavelengths, the technique is termed two-dimensional (2D) EEM fluorometry because the resulting EEM contains multiple rows and columns. EEM fluorometry - especially the 2D variety - is well established as a means of simultaneously detecting numerous dissolved and particulate compounds in water. Each compound or pool of compounds has a unique spectral fluorescence signature, and each EEM is rich in information content, in that it can contain multiple fluorescence signatures. By use of deconvolution and/or other mixture-analyses techniques, it is often possible to isolate the spectral signature of compounds of interest, even when their fluorescence spectra overlap. What distinguishes the present 2D EEMF over prior laboratory-type 2D EEMFs are several improvements in packaging (including a sealed housing) and other aspects of design that render it suitable for use in natural underwater settings. In addition, the design of the present 2D EEMF incorporates improvements over the one prior commercial underwater 2D EEMF, developed in 1994 by the same company that developed the present one. Notable advanced features of the present EEMF include the following: 1) High sensitivity and spectral resolution are achieved by use of an off-the-shelf grating spectrometer equipped with a sensor in the form of a commercial astronomical- grade 256 532-pixel charge-coupled-device (CCD) array. 2) All of the power supply, timing, control, and readout circuits for the illumination source and the CCD, ancillary environmental monitoring sensors, and circuitry for controlling a shutter or filter motor are custom-designed and mounted compactly on three circuit boards below a fourth circuit board that holds the CCD (see figure). 3) The compactness of the grating spectrometer, CCD, and circuit assembly makes it possible to fit the entire instrument into a compact package that is intended to be maneuverable underwater by one person. 4) In mass production, the cost of the complete instrument would be relatively low - estimated at approximately $30,000 at 2005 prices.
NASA Astrophysics Data System (ADS)
Jayarajan, Jayesh; Kumar, Nishant; Verma, Amarnath; Thaker, Ramkrishna
2016-05-01
Drive electronics for generating fast, bipolar clocks, which can drive capacitive loads of the order of 5-10nF are indispensable for present day Charge Coupled Devices (CCDs). Design of these high speed bipolar clocks is challenging because of the capacitive loads that have to be driven and a strict constraint on the rise and fall times. Designing drive electronics circuits for space applications becomes even more challenging due to limited number of available discrete devices, which can survive in the harsh radiation prone space environment. This paper presents the design, simulations and test results of a set of such high speed, bipolar clock drivers. The design has been tested under a thermal cycle of -15 deg C to +55 deg C under vacuum conditions and has been designed using radiation hardened components. The test results show that the design meets the stringent rise/fall time requirements of 50+/-10ns for Multiple Vertical CCD (VCCD) clocks and 20+/-5ns for Horizontal CCD (HCCD) clocks with sufficient design margins across full temperature range, with a pixel readout rate of 6.6MHz. The full design has been realized in flexi-rigid PCB with package volume of 140x160x50 mm3.
Software simulations of the detection of rapidly moving asteroids by a charge-coupled device
NASA Astrophysics Data System (ADS)
McMillan, R. S.; Stoll, C. P.
1982-10-01
A rendezvous of an unmanned probe to an earth-approaching asteroid has been given a high priority in the planning of interplanetary missions for the 1990s. Even without a space mission, much could be learned about the history of asteroids and comet nuclei if more information were available concerning asteroids with orbits which cross or approach the orbit of earth. It is estimated that the total number of earth-crossers accessible to ground-based survey telescopes should be approximately 1000. However, in connection with the small size and rapid angular motion expected of many of these objects an average of only one object is discovered per year. Attention is given to the development of the software necessary to distinguish such rapidly moving asteroids from stars and noise in continuously scanned CCD exposures of the night sky. Model and input parameters are considered along with detector sensitivity, aspects of minimum detectable displacement, and the point-spread function of the CCD.
NASA Astrophysics Data System (ADS)
Grant, Catherine E.; Prigozhin, Gregory Y.; LaMarr, Beverly; Bautz, Mark W.
2003-03-01
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The ACIS team is continuing to study the properties of the damage with an emphasis on developing techniques to mitigate charge transfer inefficiency (CTI) and spectral resolution degradation. A post-facto CTI corrector has been developed which can effectively recover much of the lost resolution. Any further improvements in performance will require knowledge of the location and amount of sacrificial charge - charge deposited along the readout path of an event which fills electron traps and changes CTI. We report on efforts by the ACIS Instrument team to characterize which charge traps cause performance degradation and the properties of the sacrificial charge seen on-orbit. We also report on attempts to correct X-ray pulseheights for the presence of sacrificial charge.
Barlier-Salsi, A
2014-12-01
The European directive 2006/25/EC requires the employer to assess and, if necessary, measure the levels of exposure to optical radiation in the workplace. Array spectroradiometers can measure optical radiation from various types of sources; however poor stray light rejection affects their accuracy. A stray light correction matrix, using a tunable laser, was developed at the National Institute of Standards and Technology (NIST). As tunable lasers are very expensive, the purpose of this study was to implement this method using only nine low power lasers; other elements of the correction matrix being completed by interpolation and extrapolation. The correction efficiency was evaluated by comparing CCD spectroradiometers with and without correction and a scanning double monochromator device as reference. Similar to findings recorded by NIST, these experiments show that it is possible to reduce the spectral stray light by one or two orders of magnitude. In terms of workplace risk assessment, this spectral stray light correction method helps determine exposure levels, with an acceptable degree of uncertainty, for the majority of workplace situations. The level of uncertainty depends upon the model of spectroradiometers used; the best results are obtained with CCD detectors having an enhanced spectral sensitivity in the UV range. Thus corrected spectroradiometers require a validation against a scanning double monochromator spectroradiometer before using them for risk assessment in the workplace.
NASA Technical Reports Server (NTRS)
Matus, Carlos V.
1989-01-01
Alignment viewed through microscope. Alignment jig positions shadow mask on charge-coupled device (CCD) so metal film deposited on it precisely. Allows CCD package to be inserted and removed without disturbing alignment of mask. Holds CCD packages securely and isolates it electrostatically while providing electrical contact to each of its pins. When alignment jig assembled with CCD, used to move mask under micrometer control.
Rubio, Angela; Rambla, José Luís; Santaella, Marcella; Gómez, M. Dolores; Orzaez, Diego; Granell, Antonio; Gómez-Gómez, Lourdes
2008-01-01
Saffron, the processed stigma of Crocus sativus, is characterized by the presence of several apocarotenoids that contribute to the color, flavor, and aroma of the spice. However, little is known about the synthesis of aroma compounds during the development of the C. sativus stigma. The developing stigma is nearly odorless, but before and at anthesis, the aromatic compound β-ionone becomes the principal norisoprenoid volatile in the stigma. In this study, four carotenoid cleavage dioxygenase (CCD) genes, CsCCD1a, CsCCD1b, CsCCD4a, and CsCCD4b, were isolated from C. sativus. Expression analysis showed that CsCCD1a was constitutively expressed, CsCCD1b was unique to the stigma tissue, but only CsCCD4a and -b had expression patterns consistent with the highest levels of β-carotene and emission of β-ionone derived during the stigma development. The CsCCD4 enzymes were localized in plastids and more specifically were present in the plastoglobules. The enzymatic activities of CsCCD1a, CsCCD1b, and CsCCD4 enzymes were determined by Escherichia coli expression, and subsequent analysis of the volatile products was generated by GC/MS. The four CCDs fell in two phylogenetically divergent dioxygenase classes, but all could cleave β-carotene at the 9,10(9′,10′) positions to yield β-ionone. The data obtained suggest that all four C. sativus CCD enzymes may contribute in different ways to the production of β-ionone. In addition, the location and precise timing of β-ionone synthesis, together with its known activity as a fragrance and insect attractant, suggest that this volatile may have a role in Crocus pollination. PMID:18611853
64 x 64 thresholding photodetector array for optical pattern recognition
NASA Astrophysics Data System (ADS)
Langenbacher, Harry; Chao, Tien-Hsin; Shaw, Timothy; Yu, Jeffrey W.
1993-10-01
A high performance 32 X 32 peak detector array is introduced. This detector consists of a 32 X 32 array of thresholding photo-transistor cells, manufactured with a standard MOSIS digital 2-micron CMOS process. A built-in thresholding function that is able to perform 1024 thresholding operations in parallel strongly distinguishes this chip from available CCD detectors. This high speed detector offers responses from one to 10 milliseconds that is much higher than the commercially available CCD detectors operating at a TV frame rate. The parallel multiple peaks thresholding detection capability makes it particularly suitable for optical correlator and optoelectronically implemented neural networks. The principle of operation, circuit design and the performance characteristics are described. Experimental demonstration of correlation peak detection is also provided. Recently, we have also designed and built an advanced version of a 64 X 64 thresholding photodetector array chip. Experimental investigation of using this chip for pattern recognition is ongoing.
NASA Astrophysics Data System (ADS)
Blain, Pascal; Michel, Fabrice; Piron, Pierre; Renotte, Yvon; Habraken, Serge
2013-08-01
Noncontact optical measurement methods are essential tools in many industrial and research domains. A family of new noncontact optical measurement methods based on the polarization states splitting technique and monochromatic light projection as a way to overcome ambient lighting for in-situ measurement has been developed. Recent works on a birefringent element, a Savart plate, allow one to build a more flexible and robust interferometer. This interferometer is a multipurpose metrological device. On one hand the interferometer can be set in front of a charge-coupled device (CCD) camera. This optical measurement system is called a shearography interferometer and allows one to measure microdisplacements between two states of the studied object under coherent lighting. On the other hand, by producing and shifting multiple sinusoidal Young's interference patterns with this interferometer, and using a CCD camera, it is possible to build a three-dimensional structured light profilometer.
Using a delta-doped CCD to determine the energy of a low-energy particle
NASA Technical Reports Server (NTRS)
Nikzad, Shouleh (Inventor); Croley, Donald R. (Inventor); Murphy, Gerald B. (Inventor)
2001-01-01
The back surface of a thinned charged-coupled device (CCD) is treated to eliminate the backside potential well that appears in a conventional thinned CCD during backside illumination. The backside of the CCD includes a delta layer of high-concentration dopant confined to less than one monolayer of the crystal semiconductor. The thinned, delta-doped CCD is used to determine the energy of a very low-energy particle that penetrates less than 1.0 nm into the CCD, such as a proton having energy less than 10 keV.
Delta-doped CCD's as low-energy particle detectors and imagers
NASA Technical Reports Server (NTRS)
Nikzad, Shouleh (Inventor); Hoenk, Michael E. (Inventor); Hecht, Michael H. (Inventor)
2002-01-01
The back surface of a thinned charged-coupled device (CCD) is treated to eliminate the backside potential well that appears in a conventional thinned CCD during backside illumination. The backside of the CCD includes a delta layer of high-concentration dopant confined to less than one monolayer of the crystal semiconductor. The thinned, delta-doped CCD is used to detect very low-energy particles that penetrate less than 1.0 nm into the CCD, including electrons having energies less than 1000 eV and protons having energies less than 10 keV.
Smith, Andrew B.; Maxwell, Anthony
2006-01-01
DNA gyrase is the only topoisomerase able to introduce negative supercoils into DNA. Absent in humans, gyrase is a successful target for antibacterial drugs. However, increasing drug resistance is a serious problem and new agents are urgently needed. The naturally-produced Escherichia coli toxin CcdB has been shown to target gyrase by what is predicted to be a novel mechanism. CcdB has been previously shown to stabilize the gyrase ‘cleavage complex’, but it has not been shown to inhibit the catalytic reactions of gyrase. We present data showing that CcdB does indeed inhibit the catalytic reactions of gyrase by stabilization of the cleavage complex and that the GyrA C-terminal DNA-wrapping domain and the GyrB N-terminal ATPase domain are dispensable for CcdB's action. We further investigate the role of specific GyrA residues in the action of CcdB by site-directed mutagenesis; these data corroborate a model for CcdB action based on a recent crystal structure of a CcdB–GyrA fragment complex. From this work, we are now able to present a model for CcdB action that explains all previous observations relating to CcdB–gyrase interaction. CcdB action requires a conformation of gyrase that is only revealed when DNA strand passage is taking place. PMID:16963775
Smith, Andrew B; Maxwell, Anthony
2006-01-01
DNA gyrase is the only topoisomerase able to introduce negative supercoils into DNA. Absent in humans, gyrase is a successful target for antibacterial drugs. However, increasing drug resistance is a serious problem and new agents are urgently needed. The naturally-produced Escherichia coli toxin CcdB has been shown to target gyrase by what is predicted to be a novel mechanism. CcdB has been previously shown to stabilize the gyrase 'cleavage complex', but it has not been shown to inhibit the catalytic reactions of gyrase. We present data showing that CcdB does indeed inhibit the catalytic reactions of gyrase by stabilization of the cleavage complex and that the GyrA C-terminal DNA-wrapping domain and the GyrB N-terminal ATPase domain are dispensable for CcdB's action. We further investigate the role of specific GyrA residues in the action of CcdB by site-directed mutagenesis; these data corroborate a model for CcdB action based on a recent crystal structure of a CcdB-GyrA fragment complex. From this work, we are now able to present a model for CcdB action that explains all previous observations relating to CcdB-gyrase interaction. CcdB action requires a conformation of gyrase that is only revealed when DNA strand passage is taking place.
Drummond, Revel S M; Martínez-Sánchez, N Marcela; Janssen, Bart J; Templeton, Kerry R; Simons, Joanne L; Quinn, Brian D; Karunairetnam, Sakuntala; Snowden, Kimberley C
2009-12-01
One of the key factors that defines plant form is the regulation of when and where branches develop. The diversity of form observed in nature results, in part, from variation in the regulation of branching between species. Two CAROTENOID CLEAVAGE DIOXYGENASE (CCD) genes, CCD7 and CCD8, are required for the production of a branch-suppressing plant hormone. Here, we report that the decreased apical dominance3 (dad3) mutant of petunia (Petunia hybrida) results from the mutation of the PhCCD7 gene and has a less severe branching phenotype than mutation of PhCCD8 (dad1). An analysis of the expression of this gene in wild-type, mutant, and grafted petunia suggests that in petunia, CCD7 and CCD8 are coordinately regulated. In contrast to observations in Arabidopsis (Arabidopsis thaliana), ccd7ccd8 double mutants in petunia show an additive phenotype. An analysis using dad3 or dad1 mutant scions grafted to wild-type rootstocks showed that when these plants produce adventitious mutant roots, branching is increased above that seen in plants where the mutant roots are removed. The results presented here indicate that mutation of either CCD7 or CCD8 in petunia results in both the loss of an inhibitor of branching and an increase in a promoter of branching.
Drummond, Revel S.M.; Martínez-Sánchez, N. Marcela; Janssen, Bart J.; Templeton, Kerry R.; Simons, Joanne L.; Quinn, Brian D.; Karunairetnam, Sakuntala; Snowden, Kimberley C.
2009-01-01
One of the key factors that defines plant form is the regulation of when and where branches develop. The diversity of form observed in nature results, in part, from variation in the regulation of branching between species. Two CAROTENOID CLEAVAGE DIOXYGENASE (CCD) genes, CCD7 and CCD8, are required for the production of a branch-suppressing plant hormone. Here, we report that the decreased apical dominance3 (dad3) mutant of petunia (Petunia hybrida) results from the mutation of the PhCCD7 gene and has a less severe branching phenotype than mutation of PhCCD8 (dad1). An analysis of the expression of this gene in wild-type, mutant, and grafted petunia suggests that in petunia, CCD7 and CCD8 are coordinately regulated. In contrast to observations in Arabidopsis (Arabidopsis thaliana), ccd7ccd8 double mutants in petunia show an additive phenotype. An analysis using dad3 or dad1 mutant scions grafted to wild-type rootstocks showed that when these plants produce adventitious mutant roots, branching is increased above that seen in plants where the mutant roots are removed. The results presented here indicate that mutation of either CCD7 or CCD8 in petunia results in both the loss of an inhibitor of branching and an increase in a promoter of branching. PMID:19846541
Improved accuracies for satellite tracking
NASA Technical Reports Server (NTRS)
Kammeyer, P. C.; Fiala, A. D.; Seidelmann, P. K.
1991-01-01
A charge coupled device (CCD) camera on an optical telescope which follows the stars can be used to provide high accuracy comparisons between the line of sight to a satellite, over a large range of satellite altitudes, and lines of sight to nearby stars. The CCD camera can be rotated so the motion of the satellite is down columns of the CCD chip, and charge can be moved from row to row of the chip at a rate which matches the motion of the optical image of the satellite across the chip. Measurement of satellite and star images, together with accurate timing of charge motion, provides accurate comparisons of lines of sight. Given lines of sight to stars near the satellite, the satellite line of sight may be determined. Initial experiments with this technique, using an 18 cm telescope, have produced TDRS-4 observations which have an rms error of 0.5 arc second, 100 m at synchronous altitude. Use of a mosaic of CCD chips, each having its own rate of charge motion, in the focal place of a telescope would allow point images of a geosynchronous satellite and of stars to be formed simultaneously in the same telescope. The line of sight of such a satellite could be measured relative to nearby star lines of sight with an accuracy of approximately 0.03 arc second. Development of a star catalog with 0.04 arc second rms accuracy and perhaps ten stars per square degree would allow determination of satellite lines of sight with 0.05 arc second rms absolute accuracy, corresponding to 10 m at synchronous altitude. Multiple station time transfers through a communications satellite can provide accurate distances from the satellite to the ground stations. Such observations can, if calibrated for delays, determine satellite orbits to an accuracy approaching 10 m rms.
Brehler, Randolf; von Schaewen, Antje
2011-01-01
Background A longstanding debate in allergy is whether or not specific immunoglobulin-E antibodies (sIgE), recognizing cross-reactive carbohydrate determinants (CCD), are able to elicit clinical symptoms. In pollen and food allergy, ≥20% of patients display in-vitro CCD reactivity based on presence of α1,3-fucose and/or β1,2-xylose residues on N-glycans of plant (xylose/fucose) and insect (fucose) glycoproteins. Because the allergenicity of tomato glycoallergen Lyc e 2 was ascribed to N-glycan chains alone, this study aimed at evaluating clinical relevance of CCD-reduced foodstuff in patients with carbohydrate-specific IgE (CCD-sIgE). Methodology/Principal Findings Tomato and/or potato plants with stable reduction of Lyc e 2 (tomato) or CCD formation in general were obtained via RNA interference, and gene-silencing was confirmed by immunoblot analyses. Two different CCD-positive patient groups were compared: one with tomato and/or potato food allergy and another with hymenoptera-venom allergy (the latter to distinguish between CCD- and peptide-specific reactions in the food-allergic group). Non-allergic and CCD-negative food-allergic patients served as controls for immunoblot, basophil activation, and ImmunoCAP analyses. Basophil activation tests (BAT) revealed that Lyc e 2 is no key player among other tomato (glyco)allergens. CCD-positive patients showed decreased (re)activity with CCD-reduced foodstuff, most obvious in the hymenoptera venom-allergic but less in the food-allergic group, suggesting that in-vivo reactivity is primarily based on peptide- and not CCD-sIgE. Peptide epitopes remained unaffected in CCD-reduced plants, because CCD-negative patient sera showed reactivity similar to wild-type. In-house-made ImmunoCAPs, applied to investigate feasibility in routine diagnosis, confirmed BAT results at the sIgE level. Conclusions/Significance CCD-positive hymenoptera venom-allergic patients (control group) showed basophil activation despite no allergic symptoms towards tomato and potato. Therefore, this proof-of-principle study demonstrates feasibility of CCD-reduced foodstuff to minimize ‘false-positive results’ in routine serum tests. Despite confirming low clinical relevance of CCD antibodies, we identified one patient with ambiguous in-vitro results, indicating need for further component-resolved diagnosis. PMID:21423762
Timing generator of scientific grade CCD camera and its implementation based on FPGA technology
NASA Astrophysics Data System (ADS)
Si, Guoliang; Li, Yunfei; Guo, Yongfei
2010-10-01
The Timing Generator's functions of Scientific Grade CCD Camera is briefly presented: it generates various kinds of impulse sequence for the TDI-CCD, video processor and imaging data output, acting as the synchronous coordinator for time in the CCD imaging unit. The IL-E2TDI-CCD sensor produced by DALSA Co.Ltd. use in the Scientific Grade CCD Camera. Driving schedules of IL-E2 TDI-CCD sensor has been examined in detail, the timing generator has been designed for Scientific Grade CCD Camera. FPGA is chosen as the hardware design platform, schedule generator is described with VHDL. The designed generator has been successfully fulfilled function simulation with EDA software and fitted into XC2VP20-FF1152 (a kind of FPGA products made by XILINX). The experiments indicate that the new method improves the integrated level of the system. The Scientific Grade CCD camera system's high reliability, stability and low power supply are achieved. At the same time, the period of design and experiment is sharply shorted.
NGS2: a focal plane array upgrade for the GeMS multiple tip-tilt wavefront sensor
NASA Astrophysics Data System (ADS)
Rigaut, François; Price, Ian; d'Orgeville, Céline; Bennet, Francis; Herrald, Nick; Paulin, Nicolas; Uhlendorf, Kristina; Garrel, Vincent; Sivo, Gaetano; Montes, Vanessa; Trujillo, Chad
2016-07-01
NGS2 is an upgrade for the multi-natural guide star tip-tilt & plate scale wavefront sensor for GeMS (Gemini Multi-Conjugate Adaptive Optics system). It uses a single Nüvü HNü-512 Electron-Multiplied CCD array that spans the entire GeMS wavefront sensor focal plane. Multiple small regions-of-interest are used to enable frame rates up to 800Hz. This set up will improve the optical throughput with respect to the current wavefront sensor, as well as streamline acquisition and allow for distortion compensation.
NASA Astrophysics Data System (ADS)
Abdullayev, B. I.; Gulmaliyev, N. I.; Majidova, S. O.; Mikayilov, Kh. M.; Rustamov, B. N.
2009-12-01
Basic technical characteristics of CCD matrix U-47 made by the Apogee Alta Instruments Inc. are provided. Short description and features of various noises introduced by optical system and CCD camera are presented. The technique of getting calibration frames: bias, dark, flat field and main stages of processing of results CCD photometry are described.
Comparative analysis of data quality and applications in vegetation of HJ-1A CCD images
NASA Astrophysics Data System (ADS)
Wei, Hongwei; Tian, Qingjiu; Huang, Yan; Wang, Yan
2014-05-01
To study the data quality and to find the differences in vegetation monitoring applications, the same region at Chuzhou Lai 'an, the data of HJ-1A CCD1 on the April 1st, 2012 and the data of HJ-1A CCD2 on the March 31, 2012 have being comparative analysis by the method of objective quality (image)assessment which selecting over five spectral image evaluation parameters: radiation precision (mean, variance, inclination, steepness), information entropy, signal-to-noise ratio, sharpness, contrast, and normalized differential vegetation index. The results show that there is little differences between the HJ-1A CCD1 and CCD2 by objective evaluation of data quality except radiation precision conform to their design theory, so the conclusion is that the difference of them without considering on the usual unless continuation;and Combination of field observation data Lai'an spectral data and GPS data (each point),selecting the normalized difference vegetation index as CCD1, CCD2 in vegetation monitoring application on the evaluation of the differences, and the specific process is based on GPS data is divided into nine small plots of spectral data ,and image data of nine one-to-one correspondence plots, and their normalized difference vegetation index values were calculated ,and measured spectra data resampling HJ-1A CCD1, CCD2 spectral response function calculated NDVI, and the results show that there is little differences between the HJ-1A CCD1 and CCD2 by objective evaluation of data quality, and, the differences of wheat `s reflection and normalized vegetation index is mainly due to calibration coefficients of CCD1 and CCD2, the differences of the solar elevation angle when obtaining the image and atmospheric conditions, so it has to consider the performance indicators as well as access conditions of CCD1 and CCD2, and to be take the normalization techniques for processing for the comparison analysis in the use of HJ-1A CCD Data to surface dynamic changes; Finally, in order to study the response of the spectral response function proposed spectral response function of impact factor, and in view of the spectral response function measured spectral data resampling only HJ-1A CCD spectral response function, calculated according to the formula of the equivalent reflectivity quantitative spectral response function, and spectral normalization of proposed theoretical Technical Support. The Objective evaluation of its application of HJ-1A CCD1, and CCD2 data quality differences research has important implications for broader application to further promote China-made remote sensing satellite data, future research also needs calibration coefficient, the solar elevation angle atmospheric conditions and its image scanning angle be taken into account, and to make the corresponding normalized its impact quantitative research has important significance for the timing changes in the application of the ecological environment in China.
Asteroid detection using a single multi-wavelength CCD scan
NASA Astrophysics Data System (ADS)
Melton, Jonathan
2016-09-01
Asteroid detection is a topic of great interest due to the possibility of diverting possibly dangerous asteroids or mining potentially lucrative ones. Currently, asteroid detection is generally performed by taking multiple images of the same patch of sky separated by 10-15 minutes, then subtracting the images to find movement. However, this is time consuming because of the need to revisit the same area multiple times per night. This paper describes an algorithm that can detect asteroids using a single CCD camera scan, thus cutting down on the time and cost of an asteroid survey. The algorithm is based on the fact that some telescopes scan the sky at multiple wavelengths with a small time separation between the wavelength components. As a result, an object moving with sufficient speed will appear in different places in different wavelength components of the same image. Using image processing techniques we detect the centroids of points of light in the first component and compare these positions to the centroids in the other components using a nearest neighbor algorithm. The algorithm was used on a test set of 49 images obtained from the Sloan telescope in New Mexico and found 100% of known asteroids with only 3 false positives. This algorithm has the advantage of decreasing the amount of time required to perform an asteroid scan, thus allowing more sky to be scanned in the same amount of time or freeing a telescope for other pursuits.
SPECKLE INTERFEROMETRY AT THE U.S. NAVAL OBSERVATORY. XV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason, Brian D.; Hartkopf, William I.; Wycoff, Gary L., E-mail: bdm@usno.navy.mi, E-mail: wih@usno.navy.mi, E-mail: glw@usno.navy.mi
2010-08-15
Results of 2433 intensified CCD observations of double stars, made with the 26 inch refractor of the U.S. Naval Observatory, are presented. Each observation of a system represents a combination of over 2000 short-exposure images. These observations are averaged into 1013 mean relative positions and range in separation from 0.''96 to 58.''05, with a mean separation of 13.''50. This paper is the 15th in the series of papers and covers the period 2008 January 3 through 2008 December 21.
2002-08-01
c~r6bral A l’autopsie. La capacit6 de faire d~vier le liquide c6phalorachidien du cerveau dans le canal rachidien en reaction A une augmentation de...expliquer la presence d’une enflure ou d’un ccd~me c~r~bral A P’autopsie. La capacit6 de faire d~vier le liquide c~phalorachidien du cerveau dans le canal
VizieR Online Data Catalog: V873 Per BVR light curves (Kriwattanawong+, 2015)
NASA Astrophysics Data System (ADS)
Kriwattanawong, W.; Poojon, P.
2015-07-01
BVR photometric observations of V873 Per were carried out on the 0.5-m telescope at Sirindhorn Observatory, Chiang Mai University. The photometric data were taken during four nights (November 27-30, 2011), by using SBIG CCD (Model of ST10-XME), with exposure time of 90s. A total of 855 individual observations were obtained in three filter bands (285 observations per filter band). The IRAF package was used for data reduction and the BVR magnitude measurements. (1 data file).
VizieR Online Data Catalog: Velocity catalog of A545 galaxies (Barrena+, 2011)
NASA Astrophysics Data System (ADS)
Barrena, R.; Girardi, M.; Boschin, W.; de Grandi, S.; Eckert, D.; Rossetti, M.
2011-08-01
Multi-object spectroscopic observations of A545 were carried out at the TNG telescope in October 2009. We used DOLORES/MOS with the LR-B Grism 1, yielding a dispersion of 187Å/mm. We used the new 2048x2048pixels E2V CCD, with a pixel size of 13.5um. In total, we observed 4 MOS masks for a total of 142 slits. We acquired three exposures of 1200s for each mask. (1 data file).
CCD TV focal plane guider development and comparison to SIRTF applications
NASA Technical Reports Server (NTRS)
Rank, David M.
1989-01-01
It is expected that the SIRTF payload will use a CCD TV focal plane fine guidance sensor to provide acquisition of sources and tracking stability of the telescope. Work has been done to develop CCD TV cameras and guiders at Lick Observatory for several years and have produced state of the art CCD TV systems for internal use. NASA decided to provide additional support so that the limits of this technology could be established and a comparison between SIRTF requirements and practical systems could be put on a more quantitative basis. The results of work carried out at Lick Observatory which was designed to characterize present CCD autoguiding technology and relate it to SIRTF applications is presented. Two different design types of CCD cameras were constructed using virtual phase and burred channel CCD sensors. A simple autoguider was built and used on the KAO, Mt. Lemon and Mt. Hamilton telescopes. A video image processing system was also constructed in order to characterize the performance of the auto guider and CCD cameras.
Rapid detection of benzoyl peroxide in wheat flour by using Raman scattering spectroscopy
NASA Astrophysics Data System (ADS)
Zhao, Juan; Peng, Yankun; Chao, Kuanglin; Qin, Jianwei; Dhakal, Sagar; Xu, Tianfeng
2015-05-01
Benzoyl peroxide is a common flour additive that improves the whiteness of flour and the storage properties of flour products. However, benzoyl peroxide adversely affects the nutritional content of flour, and excess consumption causes nausea, dizziness, other poisoning, and serious liver damage. This study was focus on detection of the benzoyl peroxide added in wheat flour. A Raman scattering spectroscopy system was used to acquire spectral signal from sample data and identify benzoyl peroxide based on Raman spectral peak position. The optical devices consisted of Raman spectrometer and CCD camera, 785 nm laser module, optical fiber, prober, and a translation stage to develop a real-time, nondestructive detection system. Pure flour, pure benzoyl peroxide and different concentrations of benzoyl peroxide mixed with flour were prepared as three sets samples to measure the Raman spectrum. These samples were placed in the same type of petri dish to maintain a fixed distance between the Raman CCD and petri dish during spectral collection. The mixed samples were worked by pretreatment of homogenization and collected multiple sets of data of each mixture. The exposure time of this experiment was set at 0.5s. The Savitzky Golay (S-G) algorithm and polynomial curve-fitting method was applied to remove the fluorescence background from the Raman spectrum. The Raman spectral peaks at 619 cm-1, 848 cm-1, 890 cm-1, 1001 cm-1, 1234 cm-1, 1603cm-1, 1777cm-1 were identified as the Raman fingerprint of benzoyl peroxide. Based on the relationship between the Raman intensity of the most prominent peak at around 1001 cm-1 and log values of benzoyl peroxide concentrations, the chemical concentration prediction model was developed. This research demonstrated that Raman detection system could effectively and rapidly identify benzoyl peroxide adulteration in wheat flour. The experimental result is promising and the system with further modification can be applicable for more products in near future.
SkyProbeBV: dual-color absolute sky transparency monitor to optimize science operations
NASA Astrophysics Data System (ADS)
Cuillandre, Jean-Charles; Magnier, Eugene; Sabin, Dan; Mahoney, Billy
2008-07-01
Mauna Kea (4200 m elevation, Hawaii) is known for its pristine seeing conditions, but sky transparency can be an issue for science operations: 25% of the nights are not photometric, a cloud coverage mostly due to high-altitude thin cirrus. The Canada-France-Hawaii Telescope (CFHT) is upgrading its real-time sky transparency monitor in the optical domain (V-band) into a dual-color system by adding a B-band channel and redesigning the entire optical and mechanical assembly. Since 2000, the original single-channel SkyProbe has gathered one exposure every minute during each observing night using a small CCD camera with a very wide field of view (35 sq. deg.) encompassing the region pointed by the telescope for science operations, and exposures long enough (30 seconds) to capture at least 100 stars of Hipparcos' Tychos catalog at high galactic latitudes (and up to 600 stars at low galactic latitudes). A key advantage of SkyProbe over direct thermal infrared imaging detection of clouds, is that it allows an accurate absolute measurement, within 5%, of the true atmospheric absorption by clouds affecting the data being gathered by the telescope's main science instrument. This system has proven crucial for decision making in the CFHT queued service observing (QSO), representing today 95% of the telescope time: science exposures taken in non-photometric conditions are automatically registered for being re-observed later on (at 1/10th of the original exposure time per pointing in the observed filters) to ensure a proper final absolute photometric calibration. If the absorption is too high, exposures can be repeated, or the observing can be done for a lower ranked science program. The new dual color system (simultaneous B & V bands) will allow a better characterization of the sky properties above Mauna Kea and should enable a better detection of the thinner cirrus (absorption down to 0.02 mag., i.e. 2%). SkyProbe is operated within the Elixir pipeline, a collection of tools used for handling the CFHT CCD mosaics (CFH12K and MegaCam), from data pre-processing to astrometric and photometric calibration.
A metagenomic survey of microbes in honey bee colony collapse disorder.
Cox-Foster, Diana L; Conlan, Sean; Holmes, Edward C; Palacios, Gustavo; Evans, Jay D; Moran, Nancy A; Quan, Phenix-Lan; Briese, Thomas; Hornig, Mady; Geiser, David M; Martinson, Vince; vanEngelsdorp, Dennis; Kalkstein, Abby L; Drysdale, Andrew; Hui, Jeffrey; Zhai, Junhui; Cui, Liwang; Hutchison, Stephen K; Simons, Jan Fredrik; Egholm, Michael; Pettis, Jeffery S; Lipkin, W Ian
2007-10-12
In colony collapse disorder (CCD), honey bee colonies inexplicably lose their workers. CCD has resulted in a loss of 50 to 90% of colonies in beekeeping operations across the United States. The observation that irradiated combs from affected colonies can be repopulated with naive bees suggests that infection may contribute to CCD. We used an unbiased metagenomic approach to survey microflora in CCD hives, normal hives, and imported royal jelly. Candidate pathogens were screened for significance of association with CCD by the examination of samples collected from several sites over a period of 3 years. One organism, Israeli acute paralysis virus of bees, was strongly correlated with CCD.
Silicide Schottky Barrier For Back-Surface-Illuminated CCD
NASA Technical Reports Server (NTRS)
Hecht, Michael H.
1990-01-01
Quantum efficiency of back-surface-illuminated charge-coupled device (CCD) increased by coating back surface with thin layer of PtSi or IrSi on thin layer of SiO2. In its interaction with positively-doped bulk Si of CCD, silicide/oxide layer forms Schottky barrier that repels electrons, promoting accumulation of photogenerated charge carriers in front-side CCD potential wells. Physical principle responsible for improvement explained in "Metal Film Increases CCD Output" (NPO-16815).
Three-dimensional device characterization by high-speed cinematography
NASA Astrophysics Data System (ADS)
Maier, Claus; Hofer, Eberhard P.
2001-10-01
Testing of micro-electro-mechanical systems (MEMS) for optimization purposes or reliability checks can be supported by device visualization whenever an optical access is available. The difficulty in such an investigation is the short time duration of dynamical phenomena in micro devices. This paper presents a test setup to visualize movements within MEMS in real-time and in two perpendicular directions. A three-dimensional view is achieved by the combination of a commercial high-speed camera system, which allows to take up to 8 images of the same process with a minimum interframe time of 10 ns for the first direction, with a second visualization system consisting of a highly sensitive CCD camera working with a multiple exposure LED illumination in the perpendicular direction. Well synchronized this provides 3-D information which is treated by digital image processing to correct image distortions and to perform the detection of object contours. Symmetric and asymmetric binary collisions of micro drops are chosen as test experiments, featuring coalescence and surface rupture. Another application shown here is the investigation of sprays produced by an atomizer. The second direction of view is a prerequisite for this measurement to select an intended plane of focus.
NASA Technical Reports Server (NTRS)
Garmire, Gordon P.; Nousek, John; Burrows, David; Ricker, George; Bautz, Mark; Doty, John; Collins, Stewart; Janesick, James
1988-01-01
The search for the optimum CCD to be used at the focal surface of the Advanced X-ray Astrophysics Facility (AXAF) is described. The physics of the interaction of X-rays in silicon through the photoelectric effect is reviewed. CCD technology at the beginning of the AXAF definition phase is summarized, and the results of the CCD enhancement program are discussed. Other sources of optimum CCDs are examined, and CCD enhancements made at MIT Lincoln Laboratory are addressed.
CCD research. [design, fabrication, and applications
NASA Technical Reports Server (NTRS)
Gassaway, J. D.
1976-01-01
The fundamental problems encountered in designing, fabricating, and applying CCD's are reviewed. Investigations are described and results and conclusions are given for the following: (1) the development of design analyses employing computer aided techniques and their application to the design of a grapped structure; (2) the role of CCD's in applications to electronic functions, in particular, signal processing; (3) extending the CCD to silicon films on sapphire (SOS); and (4) all aluminum transfer structure with low noise input-output circuits. Related work on CCD imaging devices is summarized.
Real-time optical multiple object recognition and tracking system and method
NASA Technical Reports Server (NTRS)
Chao, Tien-Hsin (Inventor); Liu, Hua-Kuang (Inventor)
1990-01-01
System for optically recognizing and tracking a plurality of objects within a field of vision. Laser (46) produces a coherent beam (48). Beam splitter (24) splits the beam into object (26) and reference (28) beams. Beam expanders (50) and collimators (52) transform the beams (26, 28) into coherent collimated light beams (26', 28'). A two-dimensional SLM (54), disposed in the object beam (26'), modulates the object beam with optical information as a function of signals from a first camera (16) which develops X and Y signals reflecting the contents of its field of vision. A hololens (38), positioned in the object beam (26') subsequent to the modulator (54), focuses the object beam at a plurality of focal points (42). A planar transparency-forming film (32), disposed with the focal points on an exposable surface, forms a multiple position interference filter (62) upon exposure of the surface and development processing of the film (32). A reflector (53) directing the reference beam (28') onto the film (32), exposes the surface, with images focused by the hololens (38), to form interference patterns on the surface. There is apparatus (16', 64) for sensing and indicating light passage through respective ones of the positions of the filter (62), whereby recognition of objects corresponding to respective ones of the positions of the filter (62) is affected. For tracking, apparatus (64) focuses light passing through the filter (62) onto a matrix of CCD's in a second camera (16') to form a two-dimensional display of the recognized objects.
A 100 Mfps image sensor for biological applications
NASA Astrophysics Data System (ADS)
Etoh, T. Goji; Shimonomura, Kazuhiro; Nguyen, Anh Quang; Takehara, Kosei; Kamakura, Yoshinari; Goetschalckx, Paul; Haspeslagh, Luc; De Moor, Piet; Dao, Vu Truong Son; Nguyen, Hoang Dung; Hayashi, Naoki; Mitsui, Yo; Inumaru, Hideo
2018-02-01
Two ultrahigh-speed CCD image sensors with different characteristics were fabricated for applications to advanced scientific measurement apparatuses. The sensors are BSI MCG (Backside-illuminated Multi-Collection-Gate) image sensors with multiple collection gates around the center of the front side of each pixel, placed like petals of a flower. One has five collection gates and one drain gate at the center, which can capture consecutive five frames at 100 Mfps with the pixel count of about 600 kpixels (512 x 576 x 2 pixels). In-pixel signal accumulation is possible for repetitive image capture of reproducible events. The target application is FLIM. The other is equipped with four collection gates each connected to an in-situ CCD memory with 305 elements, which enables capture of 1,220 (4 x 305) consecutive images at 50 Mfps. The CCD memory is folded and looped with the first element connected to the last element, which also makes possible the in-pixel signal accumulation. The sensor is a small test sensor with 32 x 32 pixels. The target applications are imaging TOF MS, pulse neutron tomography and dynamic PSP. The paper also briefly explains an expression of the temporal resolution of silicon image sensors theoretically derived by the authors in 2017. It is shown that the image sensor designed based on the theoretical analysis achieves imaging of consecutive frames at the frame interval of 50 ps.
Design and Development of Multi-Purpose CCD Camera System with Thermoelectric Cooling: Hardware
NASA Astrophysics Data System (ADS)
Kang, Y.-W.; Byun, Y. I.; Rhee, J. H.; Oh, S. H.; Kim, D. K.
2007-12-01
We designed and developed a multi-purpose CCD camera system for three kinds of CCDs; KAF-0401E(768×512), KAF-1602E(1536×1024), KAF-3200E(2184×1472) made by KODAK Co.. The system supports fast USB port as well as parallel port for data I/O and control signal. The packing is based on two stage circuit boards for size reduction and contains built-in filter wheel. Basic hardware components include clock pattern circuit, A/D conversion circuit, CCD data flow control circuit, and CCD temperature control unit. The CCD temperature can be controlled with accuracy of approximately 0.4° C in the max. range of temperature, Δ 33° C. This CCD camera system has with readout noise 6 e^{-}, and system gain 5 e^{-}/ADU. A total of 10 CCD camera systems were produced and our tests show that all of them show passable performance.
NASA Astrophysics Data System (ADS)
Wen, Lin; Li, Yu-dong; Guo, Qi; Wang, Chao-min
2018-02-01
Total ionizing dose effect is a major threat to space applications of CCD, which leads to the decrease of CCD saturation output voltage and the increase of dark signal. This paper investigated CCD and its readout circuit for experimental samples of different channel width to length ratio of MOSFET, and readout circuit amplifier, and CCD. The irradiation source was 60Co- gamma ray. through testing the parameters degradation of MOSFET and amplifier degradation, the generation and annealing law of irradiation induced defects in MOS single tube are analyzed. Combined with the radiation effect of amplifier and CCD, The correlation of radiation damage of the MOSFET and the readout circuit amplifier and CCD parameter degradation is established. Finally, this paper reveals the physical mechanism of ionizing radiation damage of the readout circuit. The research results provide a scientific basis for the selection of anti-radiation technology and structure optimization of domestic CCD.
2014-01-01
Background In saffron (Crocus sativus), new corms develop at the base of every shoot developed from the maternal corm, a globular underground storage stem. Since the degree of bud sprouts influences the number and size of new corms, and strigolactones (SLs) suppress growth of pre-formed axillary bud, it was considered appropriate to investigate SL involvement in physiology and molecular biology in saffron. We focused on two of the genes within the SL pathway, CCD7 and CCD8, encoding carotenoid cleavage enzymes required for the production of SLs. Results The CsCCD7 and CsCCD8 genes are the first ones isolated and characterized from a non-grass monocotyledonous plant. CsCCD7 and CsCCD8 expression showed some overlapping, although they were not identical. CsCCD8 was highly expressed in quiescent axillary buds and decapitation dramatically reduced its expression levels, suggesting its involvement in the suppression of axillary bud outgrowth. Furthermore, in vitro experiments showed also the involvement of auxin, cytokinin and jasmonic acid on the sprouting of axillary buds from corms in which the apical bud was removed. In addition, CsCCD8 expression, but not CsCCD7, was higher in the newly developed vascular tissue of axillary buds compared to the vascular tissue of the apical bud. Conclusions We showed that production and transport of auxin in saffron corms could act synergistically with SLs to arrest the outgrowth of the axillary buds, similar to the control of above-ground shoot branching. In addition, jasmonic acid seems to play a prominent role in bud dormancy in saffron. While cytokinins from roots promote bud outgrowth. In addition the expression results of CsCCD8 suggest that SLs could positively regulate procambial activity and the development of new vascular tissues connecting leaves with the mother corm. PMID:24947472
NASA Astrophysics Data System (ADS)
Genet, Russell M.; Fulton, B. J.; Bianco, Federica B.; Martinez, John; Baxter, John; Brewer, Mark; Carro, Joseph; Collins, Sarah; Estrada, Chris; Johnson, Jolyon; Salam, Akash; Wallen, Vera; Warren, Naomi; Smith, Thomas C.; Armstrong, James D.; McGaughey, Steve; Pye, John; Mohanan, Kakkala; Church, Rebecca
2012-05-01
Double stars have been systematically observed since William Herschel initiated his program in 1779. In 1803 he reported that, to his surprise, many of the systems he had been observing for a quarter century were gravitationally bound binary stars. In 1830 the first binary orbital solution was obtained, leading eventually to the determination of stellar masses. Double star observations have been a prolific field, with observations and discoveries - often made by students and amateurs - routinely published in a number of specialized journals such as the Journal of Double Star Observations. All published double star observations from Herschel's to the present have been incorporated in the Washington Double Star Catalog. In addition to reviewing the history of visual double stars, we discuss four observational technologies and illustrate these with our own observational results from both California and Hawaii on telescopes ranging from small SCTs to the 2-meter Faulkes Telescope North on Haleakala. Two of these technologies are visual observations aimed primarily at published "hands-on" student science education, and CCD observations of both bright and very faint doubles. The other two are recent technologies that have launched a double star renaissance. These are lucky imaging and speckle interferometry, both of which can use electron-multiplying CCD cameras to allow short (30 ms or less) exposures that are read out at high speed with very low noise. Analysis of thousands of high speed exposures allows normal seeing limitations to be overcome so very close doubles can be accurately measured.
X-ray phase contrast imaging at MAMI
NASA Astrophysics Data System (ADS)
El-Ghazaly, M.; Backe, H.; Lauth, W.; Kube, G.; Kunz, P.; Sharafutdinov, A.; Weber, T.
2006-05-01
Experiments have been performed to explore the potential of the low emittance 855MeV electron beam of the Mainz Microtron MAMI for imaging with coherent X-rays. Transition radiation from a micro-focused electron beam traversing a foil stack served as X-ray source with good transverse coherence. Refraction contrast radiographs of low absorbing materials, in particular polymer strings with diameters between 30 and 450μm, were taken with a polychromatic transition radiation X-ray source with a spectral distribution in the energy range between 8 and about 40keV. The electron beam spot size had standard deviation σh = (8.6±0.1)μm in the horizontal and σv = (7.5±0.1)μm in the vertical direction. X-ray films were used as detectors. The source-to-detector distance amounted to 11.4m. The objects were placed in a distance of up to 6m from the X-ray film. Holograms of strings were taken with a beam spot size σv = (0.50±0.05)μm in vertical direction, and a monochromatic X-ray beam of 6keV energy. A good longitudinal coherence has been obtained by the (111) reflection of a flat silicon single crystal in Bragg geometry. It has been demonstrated that a direct exposure CCD chip with a pixel size of 13×13μm^2 provides a highly efficient on-line detector. Contrast images can easily be generated with a complete elimination of all parasitic background. The on-line capability allows a minimization of the beam spot size by observing the smallest visible interference fringe spacings or the number of visible fringes. It has been demonstrated that X-ray films are also very useful detectors. The main advantage in comparison with the direct exposure CCD chip is the resolution. For the Structurix D3 (Agfa) X-ray film the standard deviation of the resolution was measured to be σf = (1.2±0.4)μm, which is about a factor of 6 better than for the direct exposure CCD chip. With the small effective X-ray spot size in vertical direction of σv = (1.2±0.3)μm and a geometrical magnification of up to 7.4 high-quality holograms of tiny transparent strings were taken in which the holographic information is contained in up to 18 interference fringes.
Massive Binaries in the R 136 Cluster
NASA Astrophysics Data System (ADS)
Morrell, N. I.; Massey, P.; Degioia-Eastwood, K.; Penny, L. R.; Gies, D. R.; Tsitkin, Y.; Darnell, E.
2008-08-01
As part of a large project aimed to the discovery and follow up of massive eclipsing systems in young clusters and stellar associations, we have obtained V-band CCD imaging of the R136 cluster in 30 Doradus, and high resolution spectroscopy of several among the variable stars we found there. Here we summarize our preliminary analysis of light and radial velocity variations for 4 massive multiple systems in the R136 cluster.
de Lasarte, Marta; Pujol, Jaume; Arjona, Montserrat; Vilaseca, Meritxell
2007-01-10
We present an optimized linear algorithm for the spatial nonuniformity correction of a CCD color camera's imaging system and the experimental methodology developed for its implementation. We assess the influence of the algorithm's variables on the quality of the correction, that is, the dark image, the base correction image, and the reference level, and the range of application of the correction using a uniform radiance field provided by an integrator cube. The best spatial nonuniformity correction is achieved by having a nonzero dark image, by using an image with a mean digital level placed in the linear response range of the camera as the base correction image and taking the mean digital level of the image as the reference digital level. The response of the CCD color camera's imaging system to the uniform radiance field shows a high level of spatial uniformity after the optimized algorithm has been applied, which also allows us to achieve a high-quality spatial nonuniformity correction of captured images under different exposure conditions.
Visualization of hump formation in high-speed gas metal arc welding
NASA Astrophysics Data System (ADS)
Wu, C. S.; Zhong, L. M.; Gao, J. Q.
2009-11-01
The hump bead is a typical weld defect observed in high-speed welding. Its occurrence limits the improvement of welding productivity. Visualization of hump formation during high-speed gas metal arc welding (GMAW) is helpful in the better understanding of the humping phenomena so that effective measures can be taken to suppress or decrease the tendency of hump formation and achieve higher productivity welding. In this study, an experimental system was developed to implement vision-based observation of the weld pool behavior during high-speed GMAW. Considering the weld pool characteristics in high-speed welding, a narrow band-pass and neutral density filter was equipped for the CCD camera, the suitable exposure time was selected and side view orientation of the CCD camera was employed. The events that took place at the rear portion of the weld pools were imaged during the welding processes with and without hump bead formation, respectively. It was found that the variation of the weld pool surface height and the solid-liquid interface at the pool trailing with time shows some useful information to judge whether the humping phenomenon occurs or not.
Time-resolved spectroscopy using a chopper wheel as a fast shutter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Shicong; Wendt, Amy E.; Boffard, John B.
Widely available, small form-factor, fiber-coupled spectrometers typically have a minimum exposure time measured in milliseconds, and thus cannot be used directly for time-resolved measurements at the microsecond level. Spectroscopy at these faster time scales is typically done with an intensified charge coupled device (CCD) system where the image intensifier acts as a “fast” electronic shutter for the slower CCD array. In this paper, we describe simple modifications to a commercially available chopper wheel system to allow it to be used as a “fast” mechanical shutter for gating a fiber-coupled spectrometer to achieve microsecond-scale time-resolved optical measurements of a periodically pulsedmore » light source. With the chopper wheel synchronized to the pulsing of the light source, the time resolution can be set to a small fraction of the pulse period by using a chopper wheel with narrow slots separated by wide spokes. Different methods of synchronizing the chopper wheel and pulsing of the light sources are explored. The capability of the chopper wheel system is illustrated with time-resolved measurements of pulsed plasmas.« less
Han, Yuanji; Wu, Miao; Cao, Liya; Yuan, Wangjun; Dong, Meifang; Wang, Xiaohui; Chen, Weicai; Shang, Fude
2016-07-01
The sweet osmanthus carotenoid cleavage dioxygenase 4 (OfCCD4) cleaves carotenoids such as β-carotene and zeaxanthin to yield β-ionone. OfCCD4 is a member of the CCD gene family, and its promoter contains a W-box palindrome with two reversely oriented TGAC repeats, which are the proposed binding sites of WRKY transcription factors. We isolated three WRKY cDNAs from the petal of Osmanthus fragrans. One of them, OfWRKY3, encodes a protein containing two WRKY domains and two zinc finger motifs. OfWRKY3 and OfCCD4 had nearly identical expression profile in petals of 'Dangui' and 'Yingui' at different flowering stages and showed similar expression patterns in petals treated by salicylic acid, jasmonic acid and abscisic acid. Activation of OfCCD4pro:GUS by OfWRKY3 was detected in coinfiltrated tobacco leaves and very weak GUS activity was detected in control tissues, indicating that OfWRKY3 can interact with the OfCCD4 promoter. Yeast one-hybrid and electrophoretic mobility shift assay showed that OfWRKY3 was able to bind to the W-box palindrome motif present in the OfCCD4 promoter. These results suggest that OfWRKY3 is a positive regulator of the OfCCD4 gene, and might partly account for the biosynthesis of β-ionone in sweet osmanthus.
High-resolution CCD imaging alternatives
NASA Astrophysics Data System (ADS)
Brown, D. L.; Acker, D. E.
1992-08-01
High resolution CCD color cameras have recently stimulated the interest of a large number of potential end-users for a wide range of practical applications. Real-time High Definition Television (HDTV) systems are now being used or considered for use in applications ranging from entertainment program origination through digital image storage to medical and scientific research. HDTV generation of electronic images offers significant cost and time-saving advantages over the use of film in such applications. Further in still image systems electronic image capture is faster and more efficient than conventional image scanners. The CCD still camera can capture 3-dimensional objects into the computing environment directly without having to shoot a picture on film develop it and then scan the image into a computer. 2. EXTENDING CCD TECHNOLOGY BEYOND BROADCAST Most standard production CCD sensor chips are made for broadcast-compatible systems. One popular CCD and the basis for this discussion offers arrays of roughly 750 x 580 picture elements (pixels) or a total array of approximately 435 pixels (see Fig. 1). FOR. A has developed a technique to increase the number of available pixels for a given image compared to that produced by the standard CCD itself. Using an inter-lined CCD with an overall spatial structure several times larger than the photo-sensitive sensor areas each of the CCD sensors is shifted in two dimensions in order to fill in spatial gaps between adjacent sensors.
Spectral analysis using the CCD Chirp Z-transform
NASA Technical Reports Server (NTRS)
Eversole, W. L.; Mayer, D. J.; Bosshart, P. W.; Dewit, M.; Howes, C. R.; Buss, D. D.
1978-01-01
The charge coupled device (CCD) Chirp Z transformation (CZT) spectral analysis techniques were reviewed and results on state-of-the-art CCD CZT technology are presented. The CZT algorithm was examined and the advantages of CCD implementation are discussed. The sliding CZT which is useful in many spectral analysis applications is described, and the performance limitations of the CZT are studied.
Documentation to the 2015-16 Common Core of Data (CCD) Universe Files. NCES 2017-074
ERIC Educational Resources Information Center
Glander, Mark
2017-01-01
The Common Core of Data (CCD) is a national statistical program that collects and compiles administrative data from SEAs covering the universe of all public elementary and secondary schools and school districts in the United States. The first CCD collection was for SY 1986-87. The predecessor to CCD was the Elementary and Secondary General…
NASA Astrophysics Data System (ADS)
Mori, Koji; Nishioka, Yusuke; Ohura, Satoshi; Koura, Yoshiaki; Yamauchi, Makoto; Nakajima, Hiroshi; Ueda, Shutaro; Kan, Hiroaki; Anabuki, Naohisa; Nagino, Ryo; Hayashida, Kiyoshi; Tsunemi, Hiroshi; Kohmura, Takayoshi; Ikeda, Shoma; Murakami, Hiroshi; Ozaki, Masanobu; Dotani, Tadayasu; Maeda, Yukie; Sagara, Kenshi
2013-12-01
We report on a proton radiation damage experiment on P-channel CCD newly developed for an X-ray CCD camera onboard the ASTRO-H satellite. The device was exposed up to 109 protons cm-2 at 6.7 MeV. The charge transfer inefficiency (CTI) was measured as a function of radiation dose. In comparison with the CTI currently measured in the CCD camera onboard the Suzaku satellite for 6 years, we confirmed that the new type of P-channel CCD is radiation tolerant enough for space use. We also confirmed that a charge-injection technique and lowering the operating temperature efficiently work to reduce the CTI for our device. A comparison with other P-channel CCD experiments is also discussed. We performed a proton radiation damage experiment on a new P-channel CCD. The device was exposed up to 109 protons cm-2 at 6.7 MeV. We confirmed that it is radiation tolerant enough for space use. We confirmed that a charge-injection technique reduces the CTI. We confirmed that lowering the operating temperature also reduces the CTI.
Chandra/ACIS Spectra of the 30 Doradus Star Forming Region
NASA Astrophysics Data System (ADS)
Townsley, L.; Broos, P.; Feigelson, E.; Burrows, D.; Chu, Y.-H.; Garmire, G.; Griffiths, R.; Maeda, Y.; Tsuboi, Y.
2000-12-01
We present the first high-spatial-resolution X-ray spectra of constituents of the 30 Doradus star-forming region in the Large Magellanic Cloud, obtained with the Advanced CCD Imaging Spectrometer (ACIS) aboard the Chandra X-ray Observatory. Our continuing efforts to remove the spectral effects of CCD charge transfer inefficiency (CTI) due to radiation damage are described. The central cluster of young high-mass stars, R136, is resolved at the arcsecond level by ACIS, allowing spectral analysis of several constituents. Other Wolf-Rayet stars and multiple systems (e.g. R139, R140) are also detected. Spatially-resolved spectra are presented for N157B, the plerion SNR recently shown by X-ray observations to contain a 16-msec pulsar (Marshall et al., ApJ 499, L179). The spectrally soft superbubble structures seen by ROSAT are visible in the Chandra image; a composite spectrum, improved with CTI correction, is presented. Support for this effort was provided by NASA contract NAS8-38252 to Gordon Garmire, the ACIS Principal Investigator.
Utilizing the Southwest Ultraviolet Imaging System (SwUIS) on the International Space Station
NASA Astrophysics Data System (ADS)
Schindhelm, Eric; Stern, S. Alan; Ennico-Smith, Kimberly
2013-09-01
We present the Southwest Ultraviolet Imaging System (SwUIS), a compact, low-cost instrument designed for remote sensing observations from a manned platform in space. It has two chief configurations; a high spatial resolution mode with a 7-inch Maksutov-Cassegrain telescope, and a large field-of-view camera mode using a lens assembly. It can operate with either an intensified CCD or an electron multiplying CCD camera. Interchangeable filters and lenses enable broadband and narrowband imaging at UV/visible/near-infrared wavelengths, over a range of spatial resolution. SwUIS has flown previously on Space Shuttle flights STS-85 and STS-93, where it recorded multiple UV images of planets, comets, and vulcanoids. We describe the instrument and its capabilities in detail. The SWUIS's broad wavelength coverage and versatile range of hardware configurations make it an attractive option for use as a facility instrument for Earth science and astronomical imaging investigations aboard the International Space Station.
Fast optical and electrical diagnostics of pulsed spark discharges in different gap geometries
NASA Astrophysics Data System (ADS)
Höft, Hans; Huiskamp, Tom; Kettlitz, Manfred
2016-09-01
Spark discharges in different electrode configurations and with various electrode materials were ignited in air at atmospheric pressure using a custom build pulse charger with 1 μs voltage rise time (up to 28 kV) in single shot operation. Fast voltage and current measurements were combined with iCCD imaging with high spatial resolution (better than 10 μm) on pin-to-pin, pin-to-half-sphere and symmetrical half-sphere tungsten electrodes and symmetrical half-sphere brass electrodes for electrode gaps of 0.1 to 0.7 mm. Breakdown voltages, consumed electrical energies and the discharge emission structures as well as the discharge diameters were obtained. Because of the synchronization of the electrical measurements and the iCCD imaging (i.e. one complete data set for every shot), it was possible to estimate the current density and the change of the discharge pattern, such as single or multiple channels, for all cases. EU funding under Grant No 316216 (PlasmaShape).
4D multiple-cathode ultrafast electron microscopy
Baskin, John Spencer; Liu, Haihua; Zewail, Ahmed H.
2014-01-01
Four-dimensional multiple-cathode ultrafast electron microscopy is developed to enable the capture of multiple images at ultrashort time intervals for a single microscopic dynamic process. The dynamic process is initiated in the specimen by one femtosecond light pulse and probed by multiple packets of electrons generated by one UV laser pulse impinging on multiple, spatially distinct, cathode surfaces. Each packet is distinctly recorded, with timing and detector location controlled by the cathode configuration. In the first demonstration, two packets of electrons on each image frame (of the CCD) probe different times, separated by 19 picoseconds, in the evolution of the diffraction of a gold film following femtosecond heating. Future elaborations of this concept to extend its capabilities and expand the range of applications of 4D ultrafast electron microscopy are discussed. The proof-of-principle demonstration reported here provides a path toward the imaging of irreversible ultrafast phenomena of materials, and opens the door to studies involving the single-frame capture of ultrafast dynamics using single-pump/multiple-probe, embedded stroboscopic imaging. PMID:25006261
4D multiple-cathode ultrafast electron microscopy.
Baskin, John Spencer; Liu, Haihua; Zewail, Ahmed H
2014-07-22
Four-dimensional multiple-cathode ultrafast electron microscopy is developed to enable the capture of multiple images at ultrashort time intervals for a single microscopic dynamic process. The dynamic process is initiated in the specimen by one femtosecond light pulse and probed by multiple packets of electrons generated by one UV laser pulse impinging on multiple, spatially distinct, cathode surfaces. Each packet is distinctly recorded, with timing and detector location controlled by the cathode configuration. In the first demonstration, two packets of electrons on each image frame (of the CCD) probe different times, separated by 19 picoseconds, in the evolution of the diffraction of a gold film following femtosecond heating. Future elaborations of this concept to extend its capabilities and expand the range of applications of 4D ultrafast electron microscopy are discussed. The proof-of-principle demonstration reported here provides a path toward the imaging of irreversible ultrafast phenomena of materials, and opens the door to studies involving the single-frame capture of ultrafast dynamics using single-pump/multiple-probe, embedded stroboscopic imaging.
Instrumentation for Laue diffraction (invited)
NASA Astrophysics Data System (ADS)
Helliwell, J. R.; Harrop, S.; Habash, J.; Magorrian, B. G.; Allinson, N. M.; Gomez, D.; Helliwell, M.; Derewenda, Z.; Cruickshank, D. W. J.
1989-07-01
Single-crystal x-ray diffraction data can be measured very quickly in Laue geometry compared with monochromatic methods. Alternatively, this gain factor can be used instead to reduce the sample volume for a fixed exposure time. In the latter case especially, there is a critical need to control parasitic scatter in the Laue camera. The use of Laue geometry as a means of quantitative data acquisition required the solution of some fundamental problems. The so-called ``overlapping orders problem'' has been found not to be limiting. It can be shown that the bulk of the Laue spots are single order, provided dhkl<2dmin where dhkl is the interplanar spacing and dmin is the resolution limit of the data. In addition, empirical wavelength normalization is required. This can be achieved by using the symmetry of the diffraction pattern. The fact that different equivalents occur at different wavelengths means that the differences in these intensities can be used to establish the ``λ curve.'' Successful wavelength normalization to date has used a relatively broad-band pass. The multiplicity distribution is the histogram of the number of spots of a given order. This distribution is determined by the ratio λmax/λmin (λmax =maximum wavelength, λmin =minimum wavelength in the beam). λmax is determined by the use of any filters in the beamline. λmin is determined either by the spectral curve or a critical cutoff if a mirror is used. A mirror can be usefully introduced to enhance the multiplicity distribution in favor of single wavelength spots or to focus the white beam; so far only vertical focussing has been used. The detector options used to date have been photographic film, Fuji image plate (at Photon Factory)/Kodak storage phosphor (at Cornell) and charge coupled device (CCD) (at Daresbury). It is useful to consider the joint theoretical spatial and energy distribution of spots in defining the detector specification and geometry. To date, we have processed Laue film data successfully. The attraction of using the CCD, even to look at a small portion of the Laue pattern, is to view the diffraction in real time. This will allow tight control of parasitic scatter for microcrystal Laue diffraction and real-time monitoring for time-resolved work. We performed initial experiments using a direct detection CCD imager, and have obtained satisfactory diffraction data on a 40 ms time scale. Results of this work will be presented. In order to assess the efficacy of the Laue method for quantitative crystallography, we have used Laue data from the protein pea lectin and compared it in detail with monochromatic pea lectin data. To assess the use of a vertically focussing mirror, we have successfully used a mercury derivative protein crystal to yield isomorphous and anomalous differences suitable for phase determination. In both the pea lectin and mercury derivative cases, doublet Laue spots were deconvoluted. In the latter case, the data were used in a difference Fourier calculation which showed the mercury peak. Future developments and projections based on multipole sources are given.
Lobato-Márquez, Damián; Molina-García, Laura; Moreno-Córdoba, Inma; García-Del Portillo, Francisco; Díaz-Orejas, Ramón
2016-01-01
Certain Salmonella enterica serovars belonging to subspecies I carry low-copy-number virulence plasmids of variable size (50-90 kb). All of these plasmids share the spv operon, which is important for systemic infection. Virulence plasmids are present at low copy numbers. Few copies reduce metabolic burden but suppose a risk of plasmid loss during bacterial division. This drawback is counterbalanced by maintenance modules that ensure plasmid stability, including partition systems and toxin-antitoxin (TA) loci. The low-copy number virulence pSLT plasmid of Salmonella enterica serovar Typhimurium encodes three auxiliary maintenance systems: one partition system ( parAB ) and two TA systems ( ccdAB ST and vapBC2 ST ). The TA module ccdAB ST has previously been shown to contribute to pSLT plasmid stability and vapBC2 ST to bacterial virulence. Here we describe a novel assay to measure plasmid stability based on the selection of plasmid-free cells following elimination of plasmid-containing cells by ParE toxin, a DNA gyrase inhibitor. Using this new maintenance assay we confirmed a crucial role of parAB in pSLT maintenance. We also showed that vapBC2 ST , in addition to contribute to bacterial virulence, is important for plasmid stability. We have previously shown that ccdAB ST encodes an inactive CcdB ST toxin. Using our new stability assay we monitored the contribution to plasmid stability of a ccdAB ST variant containing a single mutation (R99W) that restores the toxicity of CcdB ST . The "activation" of CcdB ST (R99W) did not increase pSLT stability by ccdAB ST . In contrast, ccdAB ST behaves as a canonical type II TA system in terms of transcriptional regulation. Of interest, ccdAB ST was shown to control the expression of a polycistronic operon in the pSLT plasmid. Collectively, these results show that the contribution of the CcdB ST toxin to pSLT plasmid stability may depend on its role as a co-repressor in coordination with CcdA ST antitoxin more than on its toxic activity.
Speckle Interferometry at the U.S. Naval Observatory. XXII.
NASA Astrophysics Data System (ADS)
Mason, Brian D.; Hartkopf, William I.
2017-11-01
The results of 4747 intensified CCD observations of double stars, made with the 26 inch refractor of the U.S. Naval Observatory, are presented. Each observation of a system represents a combination of over 2000 short-exposure images. These observations are averaged into 2667 mean relative positions and range in separation from 0.″328 to 95.″9, with a median separation of 8.″673. Eight orbits are improved. This is the 22nd in this series of papers and covers the period 2016 January 4 through 2016 December 29.
Evaluation of COTS Rad Detection Apps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, Eric
2014-02-01
Mobile applications are currently under distribution to smart phones utilizing the built-in charge coupled-device (CCD) camera as a radiation detector. The CCD detector has a very low but measurable gamma interaction cross section so the mechanism is feasible, especially for higher dose rate environments. Given that in a large release of radioactive material these ‘crowd sourced’ measurements will be put forth for consideration, a testing and evaluation of the accuracy and uncertainty of the Apps is a critical endeavor. Not only is the accuracy of the reported measurement of concern to the immediate user’s safety, a quantitative uncertainty is requiredmore » for a government response such as the Federal Radiological Monitoring and Assessment Center (FRMAC) to accept the values for consideration in the determination of regions exceeding protective action guidelines. Already, prompted by the Fukushima nuclear material releases, several repositories of this crowd-sourced data have been created (http://japan.failedrobot.com, http://www.stubbytour.com/nuc/index_en.asp, and http://www.rdtn.org) although the question remains as to the reliability of measurements incorporated into these repositories. In cases of conflict between the real-time published crowd-sourced data and governmental protective actions prepared literature should be on-hand documenting why the difference, if any, exists. Four applications for iOS devices were obtained along with hardware to benchmark their performance. Gamma/X-Ray Detector by Stephan Hotto, Geiger Camera by Senscare, and RadioactivityCounter App by Hotray LTD are all the applications available for distribution within the US that utilize the CCD camera sensor for detection of radiation levels. The CellRad app under development by Idaho National Laboratory for the Android platform was evaluated. In addition, iRad Geiger with the associated hardware accessory was also benchmarked. Radiation fields were generated in a Cs-137 JL Shepherd Model 89 shielded calibration range. The accuracy of the exposure rate within the box calibrator is +/- 5% of the system settings and NIST traceable. This is the same calibration unit utilized for calibration of US DOE exposure rate meters. Measurements were performed from 0.2 to 40,000 mR/hr. Included in the following sections are discussions on each of the evaluated applications and their performance in reporting radiation field measurements. Unfortunately the applications do not provide a readily identifiable quality of the measurement in order to produce error bars or even out of range conditions. In general all the CCD based applications had issues detecting consistent measurements in radiation fields less than 5 mR/hr. This is most likely attributable to the electronic noise level on the CCD’s becoming comparable to the signal level due to the ionizing radiation photons.« less
VizieR Online Data Catalog: Field RR Lyrae stars (Liska+, 2016)
NASA Astrophysics Data System (ADS)
Liska, J.; Skarka, M.; Zejda, M.; Mikulasek, Z.; de Villiers, S. N.
2016-05-01
Differential photometry for VX Her in 'table1.dat' file. New photometric measurements for VX Her were performed at Masaryk University Observatory, Brno, Czech Republic during 13 nights (April-August 2014) with 0.6-m (24-inch) Newtonian telescope, CCD G2-0402, in BVRI bands. CCD images were calibrated in a standard way (dark frame and flat field corrections). The C-Munipack software (Motl 2009) was used for this processing as well as for differential photometry. TYC 1510-269-1 and TYC 1510-149-1 were used as comparison and check stars, respectively. Differential photometry for AT Ser and SS Leo is in 'table2.dat' file. New photometric measurements for these two stars were obtained using 1-inch refractor (a photographic lens Sonnar 4/135mm, lens focal ratio/focal length) and ATIK 16IC CCD camera with green photometric filter with similar throughput as the Johnson V filter. Exposures were 30s and each five frames were combined to a single image to achieve a better signal-to-noise ratio. The time resolution of a such combined frame is about 170s. The comparison stars were HD 142799 for AT Ser and HD 100763 for SS Leo. List with candidates for binaries with RR Lyrae component - RRLyrBinCan database (version 2016 May 5) is in 'table3.dat' file. 'table4.dat' file contains false-positives binary candidates among RR Lyrae stars. 'table5.dat' and 'table6.dat' files contain used maxima timings given in GEOS RR Lyr database, or newly determined in this study. (7 data files).
Rudin, Stephen; Kuhls, Andrew T.; Yadava, Girijesh K.; Josan, Gaurav C.; Wu, Ye; Chityala, Ravishankar N.; Rangwala, Hussain S.; Ciprian Ionita, N.; Hoffmann, Kenneth R.; Bednarek, Daniel R.
2011-01-01
New cone-beam computed tomographic (CBCT) mammography system designs are presented where the detectors provide high spatial resolution, high sensitivity, low noise, wide dynamic range, negligible lag and high frame rates similar to features required for high performance fluoroscopy detectors. The x-ray detectors consist of a phosphor coupled by a fiber-optic taper to either a high gain image light amplifier (LA) then CCD camera or to an electron multiplying CCD. When a square-array of such detectors is used, a field-of-view (FOV) to 20 × 20 cm can be obtained where the images have pixel-resolution of 100 µm or better. To achieve practical CBCT mammography scan-times, 30 fps may be acquired with quantum limited (noise free) performance below 0.2 µR detector exposure per frame. Because of the flexible voltage controlled gain of the LA’s and EMCCDs, large detector dynamic range is also achievable. Features of such detector systems with arrays of either generation 2 (Gen 2) or 3 (Gen 3) LAs optically coupled to CCD cameras or arrays of EMCCDs coupled directly are compared. Quantum accounting analysis is done for a variety of such designs where either the lowest number of information carriers off the LA photo-cathode or electrons released in the EMCCDs per x-ray absorbed in the phosphor are large enough to imply no quantum sink for the design. These new LA- or EMCCD-based systems could lead to vastly improved CBCT mammography, ROI-CT, or fluoroscopy performance compared to systems using flat panels. PMID:21297904
NASA Astrophysics Data System (ADS)
Rudin, Stephen; Kuhls, Andrew T.; Yadava, Girijesh K.; Josan, Gaurav C.; Wu, Ye; Chityala, Ravishankar N.; Rangwala, Hussain S.; Ionita, N. Ciprian; Hoffmann, Kenneth R.; Bednarek, Daniel R.
2006-03-01
New cone-beam computed tomographic (CBCT) mammography system designs are presented where the detectors provide high spatial resolution, high sensitivity, low noise, wide dynamic range, negligible lag and high frame rates similar to features required for high performance fluoroscopy detectors. The x-ray detectors consist of a phosphor coupled by a fiber-optic taper to either a high gain image light amplifier (LA) then CCD camera or to an electron multiplying CCD. When a square-array of such detectors is used, a field-of-view (FOV) to 20 x 20 cm can be obtained where the images have pixel-resolution of 100 μm or better. To achieve practical CBCT mammography scan-times, 30 fps may be acquired with quantum limited (noise free) performance below 0.2 μR detector exposure per frame. Because of the flexible voltage controlled gain of the LA's and EMCCDs, large detector dynamic range is also achievable. Features of such detector systems with arrays of either generation 2 (Gen 2) or 3 (Gen 3) LAs optically coupled to CCD cameras or arrays of EMCCDs coupled directly are compared. Quantum accounting analysis is done for a variety of such designs where either the lowest number of information carriers off the LA photo-cathode or electrons released in the EMCCDs per x-ray absorbed in the phosphor are large enough to imply no quantum sink for the design. These new LA- or EMCCD-based systems could lead to vastly improved CBCT mammography, ROI-CT, or fluoroscopy performance compared to systems using flat panels.
The Matrix Rib Plating System: improving aesthetic outcomes in microvascular breast reconstruction.
Ahdoot, Michael A; Echo, Anthony; Otake, Leo R; Son, Ji; Zeidler, Kamakshi R; Saadian, Isaac; Lee, Gordon K
2013-04-01
During microvascular breast reconstruction, exposure of internal mammary vessels (IMVs) is facilitated by the removal of a portion of the rib resulting in occasional chest contour deformity (CCD). The use of rib plating may reduce CCD and reduce postoperative pain. All patients underwent microvascular breast reconstruction using IMVs. In the retrospective arm, photographs were assessed by a blinded reviewer for CCDs. In the prospective cohort, patients were randomized to rib plating with the Synthes Matrix Rib Plating System or no rib plating. Postoperatively, patients were assessed for CCD and pain. In the retrospective arm, 11 of 98 (11.2%) patients representing 12 of 130 (9.2%) breast reconstructions had a noticeable contour deformity. The average body mass index (BMI) of patients with CCDs was 26.6 kg/m. In the prospective arm, there was 16% (3 of 19) rate of visible and palpable CCDs among controls, compared to 0% rate of palpable and visible contour deformity in the rib plating group. Pain was decreased in the rib plating group on all postoperative days. The pain reduction was statistically significant at rest by postoperative day 30. The majority of patients (9 of 11) with compromised aesthetic outcomes had a BMI less than 30 kg/m, suggesting a paucity of overlying soft tissue contributed to visibility of these bony defects. Rib plating prevented chest contour deformity, reduced postoperative pain, and added limited additional morbidity. We believe that rib plating is a safe, useful adjunct to microvascular breast reconstruction using IMVs, as it may improve aesthetic outcomes and reduce postoperative pain.
NASA Astrophysics Data System (ADS)
Greene, S. E.; Ridgwell, A. J.; Schmidt, D. N.; Kirtland Turner, S.; Paelike, H.; Thomas, E.
2014-12-01
The carbonate compensation depth (CCD) is the depth below which negligible calcium carbonate is preserved in marine sediments. The long-term position of the CCD is often considered to be a powerful constraint on palaeoclimate and atmospheric CO2 concentration due to the requirement that carbonate burial balance riverine weathering over long timescales. The requirement that weathering and burial be in balance is clear, but it is less certain that burial compensates for changes in weathering via shoaling or deepening of the CCD. Because most carbonate burial occurs well above the CCD , changes in weathering fluxes may be primarily accommodated by increasing or decreasing carbonate burial at shallower depths, i.e., at or near the lysocline, the depth range over which carbonate dissolution markedly increases. Indeed, recent earth system modelling studies have suggested that the position of the CCD is relatively insensitive to changes in atmospheric pCO2. Additionally, studies have questioned the nature and strength of the relationship between the CCD, carbonate saturation state in the water column, and lysocline. To test the relationship between palaeoclimate and the location of the CCD, we reconstructed the global, long-term CCD behaviour across major Cenozoic climate transitions: the late Paleocene - early Eocene long-term warming trend (study interval ~58 to 49 Ma) and the late Eocene - early Oligocene cooling and glaciation (study interval ~38 to 27 Ma). We use Earth system modelling (GENIE) to explore the links between atmospheric pCO2 and the CCD, isolating and teasing apart the roles of total dissolved inorganic carbon, temperature, circulation, and productivity in determining the CCD.
NASA Astrophysics Data System (ADS)
Lee, John H.; Fernandez, Patricia; Madden, Tim; Molitsky, Michael; Weizeorick, John
2007-11-01
This paper will describe two ongoing detector projects being developed by the Beamline Technical Support Group at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The first project is the design and construction of two detectors: a single-CCD system and a two-by-two Mosaic CCD camera for Small-Angle X-ray Scattering (SAXS). Both of these systems utilize the Kodak KAF-4320E CCD coupled to fiber optic tapers, custom mechanical hardware, electronics, and software developed at ANL. The second project is a Fast-CCD (FCCD) detector being developed in a collaboration between ANL and Lawrence Berkeley National Laboratory (LBNL). This detector will use ANL-designed readout electronics and a custom LBNL-designed CCD, with 480×480 pixels and 96 outputs, giving very fast readout.
The In-flight Spectroscopic Performance of the Swift XRT CCD Camera During 2006-2007
NASA Technical Reports Server (NTRS)
Godet, O.; Beardmore, A.P.; Abbey, A.F.; Osborne, J.P.; Page, K.L.; Evans, P.; Starling, R.; Wells, A.A.; Angelini, L.; Burrows, D.N.;
2007-01-01
The Swift X-ray Telescope focal plane camera is a front-illuminated MOS CCD, providing a spectral response kernel of 135 eV FWHM at 5.9 keV as measured before launch. We describe the CCD calibration program based on celestial and on-board calibration sources, relevant in-flight experiences, and developments in the CCD response model. We illustrate how the revised response model describes the calibration sources well. Comparison of observed spectra with models folded through the instrument response produces negative residuals around and below the Oxygen edge. We discuss several possible causes for such residuals. Traps created by proton damage on the CCD increase the charge transfer inefficiency (CTI) over time. We describe the evolution of the CTI since the launch and its effect on the CCD spectral resolution and the gain.
Modeling the impact of preflushing on CTE in proton irradiated CCD-based detectors
NASA Astrophysics Data System (ADS)
Philbrick, R. H.
2002-04-01
A software model is described that performs a "real world" simulation of the operation of several types of charge-coupled device (CCD)-based detectors in order to accurately predict the impact that high-energy proton radiation has on image distortion and modulation transfer function (MTF). The model was written primarily to predict the effectiveness of vertical preflushing on the custom full frame CCD-based detectors intended for use on the proposed Kepler Discovery mission, but it is capable of simulating many other types of CCD detectors and operating modes as well. The model keeps track of the occupancy of all phosphorous-silicon (P-V), divacancy (V-V) and oxygen-silicon (O-V) defect centers under every CCD electrode over the entire detector area. The integrated image is read out by simulating every electrode-to-electrode charge transfer in both the vertical and horizontal CCD registers. A signal level dependency on the capture and emission of signal is included and the current state of each electrode (e.g., barrier or storage) is considered when distributing integrated and emitted signal. Options for performing preflushing, preflashing, and including mini-channels are available on both the vertical and horizontal CCD registers. In addition, dark signal generation and image transfer smear can be selectively enabled or disabled. A comparison of the charge transfer efficiency (CTE) data measured on the Hubble space telescope imaging spectrometer (STIS) CCD with the CTE extracted from model simulations of the STIS CCD show good agreement.
Characterization of Electrically Active Defects in Si Using CCD Image Sensors
1978-02-01
63 35 Dislocation Segments in CCD Imager . . . . . . . . . . . . . 64 36 422 Reflection Topograph of Dislocation Loop ir... Loops . . . . . 3 39 422 Reflection Topograph of Scratch on CCD Imager, . . . 69 40 Dark Current Display of a CCD Imager with 32 ms integration Time...made of each slice using the elon -asoorbio aold developer described in Appendix D. The inagers were then thinned using the procedure at Appendix taor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gelb, B.D.; Desnick, R.J.; Shevell, M.
1995-08-28
Cleidocranial dysplasia (CCD) is a generalized skeletal dysplasia with autosomal dominant inheritance. Recently, the CCD disease locus was localized to 23 and 17 cM regions of chromosome band 6p21 by linkage studies of seven affected families. Of note, the 23 cM region contained a microdeletion detected in one family at D6S459, an interval that was excluded in the 17 cM overlapping region. Here, linkage of CCD to 6p21 was independently confirmed with a maximal two-point LOD score of Z=5.12 with marker D6S452 at {theta}=0.00. Recombinant events in two affected individuals defined a CCD region of 7 cM from D6S465 tomore » D6S282, which overlapped with the CCD region containing the microdeletion but did not overlap with the 17 cM critical region from D6S282 to D6S291. These results suggest the refined localization of the CCD region to 6 cM spanning markers D6S438 to D6S282, thereby reviving the possibility that the CCD gene lies within the microdeletion at D6S459. 13 refs., 2 figs., 1 tab.« less
CCD radiation damage in ESA Cosmic Visions missions: assessment and mitigation
NASA Astrophysics Data System (ADS)
Lumb, David H.
2009-08-01
Charge Coupled Device (CCD) imagers have been widely used in space-borne astronomical instruments. A frequent concern has been the radiation damage effects on the CCD charge transfer properties. We review some methods for assessing the Charge Transfer Inefficiency (CTI) in CCDs. Techniques to minimise degradation using background charge injection and p-channel CCD architectures are discussed. A critical review of the claims for p-channel architectures is presented. The performance advantage for p-channel CCD performance is shown to be lower than claimed previously. Finally we present some projections for the performance in the context of some future ESA missions.
A Design and Development of Multi-Purpose CCD Camera System with Thermoelectric Cooling: Software
NASA Astrophysics Data System (ADS)
Oh, S. H.; Kang, Y. W.; Byun, Y. I.
2007-12-01
We present a software which we developed for the multi-purpose CCD camera. This software can be used on the all 3 types of CCD - KAF-0401E (768×512), KAF-1602E (15367times;1024), KAF-3200E (2184×1472) made in KODAK Co.. For the efficient CCD camera control, the software is operated with two independent processes of the CCD control program and the temperature/shutter operation program. This software is designed to fully automatic operation as well as manually operation under LINUX system, and is controled by LINUX user signal procedure. We plan to use this software for all sky survey system and also night sky monitoring and sky observation. As our results, the read-out time of each CCD are about 15sec, 64sec, 134sec for KAF-0401E, KAF-1602E, KAF-3200E., because these time are limited by the data transmission speed of parallel port. For larger format CCD, the data transmission is required more high speed. we are considering this control software to one using USB port for high speed data transmission.
NASA Astrophysics Data System (ADS)
Migiyama, Go; Sugimura, Atsuhiko; Osa, Atsushi; Miike, Hidetoshi
Recently, digital cameras are offering technical advantages rapidly. However, the shot image is different from the sight image generated when that scenery is seen with the naked eye. There are blown-out highlights and crushed blacks in the image that photographed the scenery of wide dynamic range. The problems are hardly generated in the sight image. These are contributory cause of difference between the shot image and the sight image. Blown-out highlights and crushed blacks are caused by the difference of dynamic range between the image sensor installed in a digital camera such as CCD and CMOS and the human visual system. Dynamic range of the shot image is narrower than dynamic range of the sight image. In order to solve the problem, we propose an automatic method to decide an effective exposure range in superposition of edges. We integrate multi-step exposure images using the method. In addition, we try to erase pseudo-edges using the process to blend exposure values. Afterwards, we get a pseudo wide dynamic range image automatically.
NASA Astrophysics Data System (ADS)
Dubey, Vishesh; Singh, Veena; Ahmad, Azeem; Singh, Gyanendra; Mehta, Dalip Singh
2016-03-01
We report white light phase shifting interferometry in conjunction with color fringe analysis for the detection of contaminants in water such as Escherichia coli (E.coli), Campylobacter coli and Bacillus cereus. The experimental setup is based on a common path interferometer using Mirau interferometric objective lens. White light interferograms are recorded using a 3-chip color CCD camera based on prism technology. The 3-chip color camera have lesser color cross talk and better spatial resolution in comparison to single chip CCD camera. A piezo-electric transducer (PZT) phase shifter is fixed with the Mirau objective and they are attached with a conventional microscope. Five phase shifted white light interferograms are recorded by the 3-chip color CCD camera and each phase shifted interferogram is decomposed into the red, green and blue constituent colors, thus making three sets of five phase shifted intererograms for three different colors from a single set of white light interferogram. This makes the system less time consuming and have lesser effect due to surrounding environment. Initially 3D phase maps of the bacteria are reconstructed for red, green and blue wavelengths from these interferograms using MATLAB, from these phase maps we determines the refractive index (RI) of the bacteria. Experimental results of 3D shape measurement and RI at multiple wavelengths will be presented. These results might find applications for detection of contaminants in water without using any chemical processing and fluorescent dyes.
DECam SAM 0.9-m CCD Goodman SOI Optical Spectrographs CHIRON COSMOS Goodman Filters Telescopes Blanco 4 4.4.4 Gain 4.5: CCD scales at various foci APPENDIX I: Filters for CCD Imaging II: Gain and Readout
High-frame rate multiport CCD imager and camera
NASA Astrophysics Data System (ADS)
Levine, Peter A.; Patterson, David R.; Esposito, Benjamin J.; Tower, John R.; Lawler, William B.
1993-01-01
A high frame rate visible CCD camera capable of operation up to 200 frames per second is described. The camera produces a 256 X 256 pixel image by using one quadrant of a 512 X 512 16-port, back illuminated CCD imager. Four contiguous outputs are digitally reformatted into a correct, 256 X 256 image. This paper details the architecture and timing used for the CCD drive circuits, analog processing, and the digital reformatter.
Transmission electron microscope CCD camera
Downing, Kenneth H.
1999-01-01
In order to improve the performance of a CCD camera on a high voltage electron microscope, an electron decelerator is inserted between the microscope column and the CCD. This arrangement optimizes the interaction of the electron beam with the scintillator of the CCD camera while retaining optimization of the microscope optics and of the interaction of the beam with the specimen. Changing the electron beam energy between the specimen and camera allows both to be optimized.
Lack of evidence for an association between Iridovirus and colony collapse disorder.
Tokarz, Rafal; Firth, Cadhla; Street, Craig; Cox-Foster, Diana L; Lipkin, W Ian
2011-01-01
Colony collapse disorder (CCD) is characterized by the unexplained losses of large numbers of adult worker bees (Apis mellifera) from apparently healthy colonies. Although infections, toxins, and other stressors have been associated with the onset of CCD, the pathogenesis of this disorder remains obscure. Recently, a proteomics study implicated a double-stranded DNA virus, invertebrate iridescent virus (Family Iridoviridae) along with a microsporidium (Nosema sp.) as the cause of CCD. We tested the validity of this relationship using two independent methods: (i) we surveyed healthy and CCD colonies from the United States and Israel for the presence of members of the Iridovirus genus and (ii) we reanalyzed metagenomics data previously generated from RNA pools of CCD colonies for the presence of Iridovirus-like sequences. Neither analysis revealed any evidence to suggest the presence of an Iridovirus in healthy or CCD colonies.
Lack of Evidence for an Association between Iridovirus and Colony Collapse Disorder
Street, Craig; Cox-Foster, Diana L.; Lipkin, W. Ian
2011-01-01
Colony collapse disorder (CCD) is characterized by the unexplained losses of large numbers of adult worker bees (Apis mellifera) from apparently healthy colonies. Although infections, toxins, and other stressors have been associated with the onset of CCD, the pathogenesis of this disorder remains obscure. Recently, a proteomics study implicated a double-stranded DNA virus, invertebrate iridescent virus (Family Iridoviridae) along with a microsporidium (Nosema sp.) as the cause of CCD. We tested the validity of this relationship using two independent methods: (i) we surveyed healthy and CCD colonies from the United States and Israel for the presence of members of the Iridovirus genus and (ii) we reanalyzed metagenomics data previously generated from RNA pools of CCD colonies for the presence of Iridovirus-like sequences. Neither analysis revealed any evidence to suggest the presence of an Iridovirus in healthy or CCD colonies. PMID:21738798
Fully depleted back illuminated CCD
Holland, Stephen Edward
2001-01-01
A backside illuminated charge coupled device (CCD) is formed of a relatively thick high resistivity photon sensitive silicon substrate, with frontside electronic circuitry, and an optically transparent backside ohmic contact for applying a backside voltage which is at least sufficient to substantially fully deplete the substrate. A greater bias voltage which overdepletes the substrate may also be applied. One way of applying the bias voltage to the substrate is by physically connecting the voltage source to the ohmic contact. An alternate way of applying the bias voltage to the substrate is to physically connect the voltage source to the frontside of the substrate, at a point outside the depletion region. Thus both frontside and backside contacts can be used for backside biasing to fully deplete the substrate. Also, high resistivity gaps around the CCD channels and electrically floating channel stop regions can be provided in the CCD array around the CCD channels. The CCD array forms an imaging sensor useful in astronomy.
High-Voltage Clock Driver for Photon-Counting CCD Characterization
NASA Technical Reports Server (NTRS)
Baker, Robert
2013-01-01
A document discusses the CCD97 from e2v technologies as it is being evaluated at Goddard Space Flight Center's Detector Characterization Laboratory (DCL) for possible use in ultra-low background noise space astronomy applications, such as Terrestrial Planet Finder Coronagraph (TPF-C). The CCD97 includes a photoncounting mode where the equivalent output noise is less than one electron. Use of this mode requires a clock signal at a voltage level greater than the level achievable by the existing CCD (charge-coupled-device) electronics. A high-voltage waveform generator has been developed in code 660/601 to support the CCD97 evaluation. The unit generates required clock waveforms at voltage levels from -20 to +50 V. It deals with standard and arbitrary waveforms and supports pixel rates from 50 to 500 kHz. The system is designed to interface with existing Leach CCD electronics.
Hult, Johan; Richter, Mattias; Nygren, Jenny; Aldén, Marcus; Hultqvist, Anders; Christensen, Magnus; Johansson, Bengt
2002-08-20
High-repetition-rate laser-induced fluorescence measurements of fuel and OH concentrations in internal combustion engines are demonstrated. Series of as many as eight fluorescence images, with a temporal resolution ranging from 10 micros to 1 ms, are acquired within one engine cycle. A multiple-laser system in combination with a multiple-CCD camera is used for cycle-resolved imaging in spark-ignition, direct-injection stratified-charge, and homogeneous-charge compression-ignition engines. The recorded data reveal unique information on cycle-to-cycle variations in fuel transport and combustion. Moreover, the imaging system in combination with a scanning mirror is used to perform instantaneous three-dimensional fuel-concentration measurements.
NASA Technical Reports Server (NTRS)
Janesick, J. R.; Elliott, T.; Collins, S.; Marsh, H.; Blouke, M. M.
1984-01-01
Since the first introduction of charge-coupled devices (CCDs) in 1970, CCDs have been considered for applications related to memories, logic circuits, and the detection of visible radiation. It is pointed out, however, that the mass market orientation of CCD development has left largely untapped the enormous potential of these devices for advanced scientific instrumentation. The present paper has, therefore, the objective to introduce the CCD characteristics to the scientific community, taking into account prospects for further improvement. Attention is given to evaluation criteria, a summary of current CCDs, CCD performance characteristics, absolute calibration tools, quantum efficiency, aspects of charge collection, charge transfer efficiency, read noise, and predictions regarding the characteristics of the next generation of silicon scientific CCD imagers.
Enhanced performance CCD output amplifier
Dunham, Mark E.; Morley, David W.
1996-01-01
A low-noise FET amplifier is connected to amplify output charge from a che coupled device (CCD). The FET has its gate connected to the CCD in common source configuration for receiving the output charge signal from the CCD and output an intermediate signal at a drain of the FET. An intermediate amplifier is connected to the drain of the FET for receiving the intermediate signal and outputting a low-noise signal functionally related to the output charge signal from the CCD. The amplifier is preferably connected as a virtual ground to the FET drain. The inherent shunt capacitance of the FET is selected to be at least equal to the sum of the remaining capacitances.
Advances in CCD detector technology for x-ray diffraction applications
NASA Astrophysics Data System (ADS)
Thorson, Timothy A.; Durst, Roger D.; Frankel, Dan; Bordwell, Rex L.; Camara, Jose R.; Leon-Guerrero, Edward; Onishi, Steven K.; Pang, Francis; Vu, Paul; Westbrook, Edwin M.
2004-01-01
Phosphor-coupled CCDs are established as one of the most successful technologies for x-ray diffraction. This application demands that the CCD simultaneously achieve both the highest possible sensitivity and high readout speeds. Recently, wafer-scale, back illuminated devices have become available which offer significantly higher quantum efficiency than conventional devices (the Fairchild Imaging CCD 486 BI). However, since back thinning significantly changes the electrical properties of the CCD the high speed operation of wafer-scale, back-illuminated devices is not well understood. Here we describe the operating characteristics (including noise, linearity, full well capacity and CTE) of the back-illuminated CCD 486 at readout speeds up to 4 MHz.
Scientific CCD technology at JPL
NASA Technical Reports Server (NTRS)
Janesick, J.; Collins, S. A.; Fossum, E. R.
1991-01-01
Charge-coupled devices (CCD's) were recognized for their potential as an imaging technology almost immediately following their conception in 1970. Twenty years later, they are firmly established as the technology of choice for visible imaging. While consumer applications of CCD's, especially the emerging home video camera market, dominated manufacturing activity, the scientific market for CCD imagers has become significant. Activity of the Jet Propulsion Laboratory and its industrial partners in the area of CCD imagers for space scientific instruments is described. Requirements for scientific imagers are significantly different from those needed for home video cameras, and are described. An imager for an instrument on the CRAF/Cassini mission is described in detail to highlight achieved levels of performance.
Digital Mammography with a Mosaic of CCD-Arrays
NASA Technical Reports Server (NTRS)
Jalink, Antony, Jr. (Inventor); McAdoo, James A. (Inventor)
1996-01-01
The present invention relates generally to a mammography device and method and more particularly to a novel digital mammography device and method to detect microcalcifications of precancerous tissue. A digital mammography device uses a mosaic of electronic digital imaging arrays to scan an x-ray image. The mosaic of arrays is repositioned several times to expose different portions of the image, until the entire image is scanned. The data generated by the arrays during each exposure is stored in a computer. After the final exposure, the computer combines data of the several partial images to produce a composite of the original x-ray image. An aperture plate is used to reduce scatter and the overall exposure of the patient to x-rays. The novelty of this invention is that it provides a digital mammography device with large field coverage, high spatial resolution, scatter rejection, excellent contrast characteristics and lesion detectability under clinical conditions. This device also shields the patient from excessive radiation, can detect extremely small calcifications and allows manipulation and storage of the image.
Cryostat and CCD for MEGARA at GTC
NASA Astrophysics Data System (ADS)
Castillo-Domínguez, E.; Ferrusca, D.; Tulloch, S.; Velázquez, M.; Carrasco, E.; Gallego, J.; Gil de Paz, A.; Sánchez, F. M.; Vílchez Medina, J. M.
2012-09-01
MEGARA (Multi-Espectrógrafo en GTC de Alta Resolución para Astronomía) is the new integral field unit (IFU) and multi-object spectrograph (MOS) instrument for the GTC. The spectrograph subsystems include the pseudo-slit, the shutter, the collimator with a focusing mechanism, pupil elements on a volume phase holographic grating (VPH) wheel and the camera joined to the cryostat through the last lens, with a CCD detector inside. In this paper we describe the full preliminary design of the cryostat which will harbor the CCD detector for the spectrograph. The selected cryogenic device is an LN2 open-cycle cryostat which has been designed by the "Astronomical Instrumentation Lab for Millimeter Wavelengths" at INAOE. A complete description of the cryostat main body and CCD head is presented as well as all the vacuum and temperature sub-systems to operate it. The CCD is surrounded by a radiation shield to improve its performance and is placed in a custom made mechanical mounting which will allow physical adjustments for alignment with the spectrograph camera. The 4k x 4k pixel CCD231 is our selection for the cryogenically cooled detector of MEGARA. The characteristics of this CCD, the internal cryostat cabling and CCD controller hardware are discussed. Finally, static structural finite element modeling and thermal analysis results are shown to validate the cryostat model.
Robotic CCD microscope for enhanced crystal recognition
Segelke, Brent W.; Toppani, Dominique
2007-11-06
A robotic CCD microscope and procedures to automate crystal recognition. The robotic CCD microscope and procedures enables more accurate crystal recognition, leading to fewer false negative and fewer false positives, and enable detection of smaller crystals compared to other methods available today.
Optical CT scanning of PRESAGETM polyurethane samples with a CCD-based readout system
NASA Astrophysics Data System (ADS)
Doran, S. J.; Krstajic, N.; Adamovics, J.; Jenneson, P. M.
2004-01-01
This article demonstrates the resolution capabilities of the CCD scanner under ideal circumstances and describes the first CCD-based optical CT experiments on a new class of dosimeter, known as PRESAGETM (Heuris Pharma, Skillman, NJ).
Aziz, Danish Abdul; Kahlid, Misha; Memon, Fozia; Sadiq, Kamran
2017-01-01
To determine clinical features and relevant laboratory investigations of patient with celiac disease (CD) and comparing classical celiac disease (CCD) with Non-diarrheal celiac disease (NDCD). This is a five years retrospective study conducted at The Aga Khan University Hospital Karachi, Pakistan from January 2010 to December 2015, enrolling children from one year to 15 years of either gender diagnosed as celiac disease in accordance with revised ESPGHAN criteria. Biopsy samples with grade 2 or more on Modified Marsh Classification were considered as consistent with celiac disease. Celiac patients were categorized into Classical celiac disease (with Chronic Diarrhea) and non-diarrheal celiac disease (Atypical celiac) and their clinical features and relevant laboratory investigations were documented. Total 66 patients were selected with celiac disease according to inclusion criteria, 39 (59.09%) patients were labeled as CCD and 27 (40.91%) patients were labeled as NDCD. Marsh grading 3a and above were more marked in CCD as compared to NDCD. Mean titer for Tissue transglutaminase antibodies (TTG) were higher in CCD group in comparison to NDCD group. In CCD, the most common clinical presentations were abdominal distension whereas in NDCD, the most remarkable features were recurrent abdominal pain (62.9%). Frequency of failure to thrive is significantly high in CCD (82.05%) but patients merely with short stature were more common in NDCD (33.3%). Refractory anemia was present in 66.6% patients in NDCD group and 41.1% patients in CCD group. 74.3% patients in CCD group were vitamin D deficient whereas 85% patient had vitamin D deficiency in NDCD group (p= 0.03). NDCD is not uncommon in our population. Recurrent abdominal pain, failure to thrive or patients only with short stature and refractory anemia are prominent features in NCDC group whereas abdominal distension, failure to thrive and recurrent abdominal pain were noticeable features in CCD. High grade histopathology and raised antibodies titer is hallmark of CCD. Vitamin D deficiency is almost equally present in both groups.
Multiple Target Tracking in a Wide-Field-of-View Camera System
1990-01-01
assembly is mounted on a Contraves alt-azi axis table with a pointing accuracy of < 2 Urad. * Work performed under the auspices of the U.S. Department of... Contraves SUN 3 CCD DR11W VME EITHERNET SUN 3 !3T 3 RS170 Video 1 Video ^mglifier^ I WWV Clock VCR Datacube u Monitor Monitor UL...displaying processed images with overlay from the Datacube. We control the Contraves table using a GPIB interface on the SUN. GPIB also interfaces a
True 3D digital holographic tomography for virtual reality applications
NASA Astrophysics Data System (ADS)
Downham, A.; Abeywickrema, U.; Banerjee, P. P.
2017-09-01
Previously, a single CCD camera has been used to record holograms of an object while the object is rotated about a single axis to reconstruct a pseudo-3D image, which does not show detailed depth information from all perspectives. To generate a true 3D image, the object has to be rotated through multiple angles and along multiple axes. In this work, to reconstruct a true 3D image including depth information, a die is rotated along two orthogonal axes, and holograms are recorded using a Mach-Zehnder setup, which are subsequently numerically reconstructed. This allows for the generation of multiple images containing phase (i.e., depth) information. These images, when combined, create a true 3D image with depth information which can be exported to a Microsoft® HoloLens for true 3D virtual reality.
NASA Astrophysics Data System (ADS)
Zheng, Puchao; Li, Enpu; Zhao, Jianlin; Di, Jianglei; Zhou, Wangmin; Wang, Hao; Zhang, Ruifeng
2009-11-01
By using digital holographic interferometory with phase multiplication, the visualized measurement of the acoustic levitation field (ALF) with single axis is carried out. The digital holograms of the ALF under different conditions are recorded by use of CCD. The corresponding digital holographic interferograms reflecting the sound pressure distribution and the interference phase distribution are obtained by numerical reconstruction and phase subtraction, which are consistent with the theoretical results. It indicates that the proposed digital holographic interferometory with phase multiplication can successfully double the fringe number of the interference phase patterns of the ALF and improve the measurement precision. Compared with the conventional optical holographic interferometory, digital holographic interferometory has the merits of quasi real-time, more exactitude and convenient operation, and it provides an effective way for studying the sound pressure distribution of the ALF.
CCD filter and transform techniques for interference excision
NASA Technical Reports Server (NTRS)
Borsuk, G. M.; Dewitt, R. N.
1976-01-01
The theoretical and some experimental results of a study aimed at applying CCD filter and transform techniques to the problem of interference excision within communications channels were presented. Adaptive noise (interference) suppression was achieved by the modification of received signals such that they were orthogonal to the recently measured noise field. CCD techniques were examined to develop real-time noise excision processing. They were recursive filters, circulating filter banks, transversal filter banks, an optical implementation of the chirp Z transform, and a CCD analog FFT.
VizieR Online Data Catalog: BVR light curves of UZ Leo (Lee+, 2018)
NASA Astrophysics Data System (ADS)
Lee, J. W.; Park, J.-H.
2018-04-01
We performed new CCD photometry of UZ Leo during two observing seasons between 2012 February and 2013 April, using a PIXIS: 2048B CCD and a BVR filter set attached to the 61 cm reflector at Sobaeksan Optical Astronomy Observatory (SOAO) in Korea. The CCD chip has 2048x2048pixels and a pixel size of 13.5um, so the field of view of a CCD frame is 17.6'x17.6'. (1 data file).
NASA Astrophysics Data System (ADS)
Zirin, H.; Cameron, R.
1998-05-01
We have studied several hundred images of solar spicules obtained on June 18 and 19 and July 15 of 1997. The observations were made at BBSO with the 65cm telescope feeding a Zeiss 1/4 Angstroms filter and a 1536x1024 Kodak CCD. Overexposed observations were made above the limb as well as normal exposures on the limb. The filter was tuned to Hα -0.65A and a 30sec interval was used. We were limited to a single wavelength because new software was being installed in a new control computer. The images obtained were processed by high-pass digital filtering of the original FITS images and reregistered by an FFT technique. The image scale is 0.17 arcsec per pixel. The disk was observed on June 18, 1997 to detect the sources of macrospicules and the limb was observed by overexposure on June 19 to determine the height trajectory of the faintest Hα We found that: Many more spicules go up than come down. There are numerous double and multiple spicules. The macrospicules come from normal network elements and start with an "Eiffel tower" shape. There is evidence of magnetic changes underlying these features. Both long macrospicules and complex eruptions are important at the pole. There is some evidence for rotation in spicules.
Single-exposure color digital holography
NASA Astrophysics Data System (ADS)
Feng, Shaotong; Wang, Yanhui; Zhu, Zhuqing; Nie, Shouping
2010-11-01
In this paper, we report a method for color image reconstruction by recording only one single multi-wavelength hologram. In the recording process, three lasers of different wavelengths emitting in the red, green and blue regions are used for illuminating on the object and the object diffraction fields will arrive at the hologram plane simultaneously. Three reference beams with different spatial angles will interfere with the corresponding object diffraction fields on the hologram plane, respectively. Finally, a series of sub-holograms incoherently overlapped on the CCD to be recorded as a multi-wavelength hologram. Angular division multiplexing is employed to reference beams so that the spatial spectra of the multiple recordings will be separated in the Fourier plane. In the reconstruction process, the multi-wavelength hologram will be Fourier transformed into its Fourier plane, where the spatial spectra of different wavelengths are separated and can be easily extracted by employing frequency filtering. The extracted spectra are used to reconstruct the corresponding monochromatic complex amplitudes, which will be synthesized to reconstruct the color image. For singleexposure recording technique, it is convenient for applications on the real-time image processing fields. However, the quality of the reconstructed images is affected by speckle noise. How to improve the quality of the images needs for further research.
NASA Astrophysics Data System (ADS)
Zitzelsberger, Horst; Fung, Jingly; Janish, C.; McNamara, George; Bryant, P. E.; Riches, A. C.; Weier, Heinz-Ulli G.
1999-05-01
Radiocarcinogenesis is widely recognized as occupational, environmental and therapeutical hazard, but the underlying mechanisms and cellular targets have not yet been identified. We applied SKY to study chromosomal rearrangements leading to malignant transformation of irradiated thyroid epithelial cells. SKY is a recently developed technique to detect translocations involving non-homologous based on unique staining of all 24 human chromosomes by hybridization with a mixture of whole chromosome painting probes. A tuneable interferometer mounted on a fluorescence microscope in front of a CCD camera allows to record the 400 nm - 1000 nm fluorescence spectrum for each pixel in the image. After background correction, spectra recorded for each pixel are compared to reference spectra stored previously for each chromosome-specific probe. Thus, pixel spectra can be associated with specific chromosomes and displayed in 'classification' colors, which are defined so that even small translocations become readily discernible. SKY analysis was performed on several radiation-transformed cell lines. Line S48T was generated from a primary tumor of a child exposed to elevated levels of radiation following the Chernobyl nuclear accident. Subclones were generated from the human thyroid epithelial cell line (HTori-3) by exposure to gamma or alpha irradiation. SKY analysis revealed multiple translocations and, combined with G-banding, allowed the definition of targets for positional cloning of tumor related genes.
VizieR Online Data Catalog: Collinder 261 Chandra sources & optical counterparts (Vats+, 2017)
NASA Astrophysics Data System (ADS)
Vats, S.; van den Berg, M.
2017-10-01
Cr 261 was observed with the Advanced CCD Imaging Spectrometer (ACIS) on board Chandra starting 2009 November 9 14:50 UTC, for a total exposure time of 53.8ks (ObsID 11308). We retrieved optical images of Cr 261 in the B and V bands from the ESO public archive. These data were taken as part of the ESO Imaging Survey (EIS; program ID 164.O-0561). The observations of Cr 261 were made using the Wide Field Imager (WFI), mounted on the 2.2m MPG/ESO telescope at La Silla, Chile. The Cr 261 data were taken from 2001 June 27 23:55 UTC to 2001 June 28 00:38 UTC, with a total exposure time of 510s in the B and V filter each. (2 data files).
NASA Astrophysics Data System (ADS)
Garza, Alejandro J.; Sousa Alencar, Ana G.; Scuseria, Gustavo E.
2015-12-01
Singlet-paired coupled cluster doubles (CCD0) is a simplification of CCD that relinquishes a fraction of dynamic correlation in order to be able to describe static correlation. Combinations of CCD0 with density functionals that recover specifically the dynamic correlation missing in the former have also been developed recently. Here, we assess the accuracy of CCD0 and CCD0+DFT (and variants of these using Brueckner orbitals) as compared to well-established quantum chemical methods for describing ground-state properties of singlet actinide molecules. The f0 actinyl series (UO22+, NpO23+, PuO24+), the isoelectronic NUN, and thorium (ThO, ThO2+) and nobelium (NoO, NoO2) oxides are studied.
A programmable CCD driver circuit for multiphase CCD operation
NASA Technical Reports Server (NTRS)
Ewin, Audrey J.; Reed, Kenneth V.
1989-01-01
A programmable CCD (charge-coupled device) driver circuit was designed to drive CCDs in multiphased modes. The purpose of the drive electronics is to operate developmental CCD imaging arrays for NASA's tiltable moderate resolution imaging spectrometer (MODIS-T). Five objectives for the driver were considered during its design: (1) the circuit drives CCD electrode voltages between 0 V and +30 V to produce reasonable potential wells, (2) the driving sequence is started with one input signal, (3) the driving sequence is started with one input signal, (4) the circuit allows programming of frame sequences required by arrays of any size, (5) it produces interfacing signals for the CCD and the DTF (detector test facility). Simulation of the driver verified its function with the master clock running up to 10 MHz. This suggests a maximum rate of 400,000 pixels/s. Timing and packaging parameters were verified. The design uses 54 TTL (transistor-transistor logic) chips. Two versions of hardware were fabricated: wirewrap and printed circuit board. Both were verified functionally with a logic analyzer.
Smith, Andrew B; López-Villarejo, Juan; Diago-Navarro, Elizabeth; Mitchenall, Lesley A; Barendregt, Arjan; Heck, Albert J; Lemonnier, Marc; Maxwell, Anthony; Díaz-Orejas, Ramón
2012-01-01
Bacterial toxin-antitoxin (TA) systems encode two proteins, a potent inhibitor of cell proliferation (toxin) and its specific antidote (antitoxin). Structural data has revealed striking similarities between the two model TA toxins CcdB, a DNA gyrase inhibitor encoded by the ccd system of plasmid F, and Kid, a site-specific endoribonuclease encoded by the parD system of plasmid R1. While a common structural fold seemed at odds with the two clearly different modes of action of these toxins, the possibility of functional crosstalk between the parD and ccd systems, which would further point to their common evolutionary origin, has not been documented. Here, we show that the cleavage of RNA and the inhibition of protein synthesis by the Kid toxin, two activities that are specifically counteracted by its cognate Kis antitoxin, are altered, but not inhibited, by the CcdA antitoxin. In addition, Kis was able to inhibit the stimulation of DNA gyrase-mediated cleavage of DNA by CcdB, albeit less efficiently than CcdA. We further show that physical interactions between the toxins and antitoxins of the different systems do occur and define the stoichiometry of the complexes formed. We found that CcdB did not degrade RNA nor did Kid have any reproducible effect on the tested DNA gyrase activities, suggesting that these toxins evolved to reach different, rather than common, cellular targets.
Hewetson, Ronelle; Cornwell, Petrea; Shum, David
2017-07-01
Rehabilitation positively influences return to activities and social roles in people with aphasia. The cognitive-communication disorder (CCD) found following a right hemisphere stroke has been less extensively researched with rehabilitation access and outcomes yet to be determined. To document rehabilitation access and outcomes for people with CCD post-stroke; and compare outcomes based on presence (viz CCD; aphasia) or absence of communication impairment. A retrospective chart audit was completed for patients with first onset unilateral stroke, with a hospital length of stay (LOS) of at least two days and a communication assessment by a speech pathologist. Data extracted included presence and severity of communication impairment, access to and LOS in a rehabilitation unit, and functional outcome measures recorded at rehabilitation discharge. The majority of the 115 patients who met inclusion criteria were living independently (n = 112, 97.4%) at the time of stroke. CCD (66%) was diagnosed with similar frequency to aphasia (68%). The presence of communication impairment did not result in significant differences in rehabilitation LOS and discharge destination when compared to hemispheric strokes without communication impairment. Severity of CCD was an independent predictor of functional gain by rehabilitation discharge. People with CCD require comparable access to rehabilitation as people with aphasia, and severity of CCD should be considered in determining rehabilitation LOS. A large number of people are discharged with ongoing CCD which warrants exploration of potential participation restrictions created by the communication impairment.
Mitchenall, Lesley A.; Barendregt, Arjan; Heck, Albert J.; Lemonnier, Marc; Maxwell, Anthony; Díaz-Orejas, Ramón
2012-01-01
Bacterial toxin-antitoxin (TA) systems encode two proteins, a potent inhibitor of cell proliferation (toxin) and its specific antidote (antitoxin). Structural data has revealed striking similarities between the two model TA toxins CcdB, a DNA gyrase inhibitor encoded by the ccd system of plasmid F, and Kid, a site-specific endoribonuclease encoded by the parD system of plasmid R1. While a common structural fold seemed at odds with the two clearly different modes of action of these toxins, the possibility of functional crosstalk between the parD and ccd systems, which would further point to their common evolutionary origin, has not been documented. Here, we show that the cleavage of RNA and the inhibition of protein synthesis by the Kid toxin, two activities that are specifically counteracted by its cognate Kis antitoxin, are altered, but not inhibited, by the CcdA antitoxin. In addition, Kis was able to inhibit the stimulation of DNA gyrase-mediated cleavage of DNA by CcdB, albeit less efficiently than CcdA. We further show that physical interactions between the toxins and antitoxins of the different systems do occur and define the stoichiometry of the complexes formed. We found that CcdB did not degrade RNA nor did Kid have any reproducible effect on the tested DNA gyrase activities, suggesting that these toxins evolved to reach different, rather than common, cellular targets. PMID:23029540
High Resolution Spectrograph for the Hobby-Eberly Telescope
NASA Astrophysics Data System (ADS)
Tull, R. G.; MacQueen, P. J.; Good, J.; Epps, H. W.; HET HRS Team
1998-12-01
A fiber fed high-resolution spectrograph (HRS) is under construction for the Hobby-Eberly Telescope (HET). The primary resolving power originally specified, from astrophysical considerations, was R = 60,000 with a fiber of diameter at least 1 arc-second, with full spectral coverage limited only by the combined band-pass of the HET, the optical fiber, and the image detector. This was achieved in the final design with a high blaze angle R-4 echelle mosaic, white pupil design, image slicing, and a large area CCD mosaic illuminated by an eight element refractive camera. Two back-to-back, user selectable first-order diffraction gratings are employed for cross dispersion, to separate echelle spectral orders; the entire spectral range (420 - 1,000 nm) can be covered in as few as two exposures. Critical issues addressed in the design are cross dispersion and order spacing, sky subtraction, echelle and CCD selection, fiber optic feed and scrambling, and image or pupil slicing. In the final design meeting the requirements we exploited the large-area 4096 square CCD, image slicing, and the optical performance of the white-pupil design to acquire a range of 30,000 < R < 120,000 with fibers of diameter 2 and 3 arc-seconds, without sacrificing full spectral coverage. Design details will be presented. Limiting magnitude is projected to be about V = 19 (for S/N = 10) at the nominal R = 60,000 resolving power. The poster display will outline performance characteristics expected in relation to projected astrophysical research capabilities outlined by Sneden et al., in this conference. HRS is supported by generous grants from NSF, NASA, the State of Texas, and private philanthropy, with matching funds granted by the University of Texas and by McDonald Observatory.
SPECKLE INTERFEROMETRY AT THE U.S. NAVAL OBSERVATORY. XVII
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason, Brian D.; Hartkopf, William I.; Wycoff, Gary L., E-mail: bdm@usno.navy.mil, E-mail: wih@usno.navy.mil
2011-08-15
The results of 3362 intensified CCD observations of double stars, made with the 26 inch refractor of the U.S. Naval Observatory, are presented. Each observation of a system represents a combination of over 2000 short-exposure images. These observations are averaged into 1970 mean relative positions and range in separation from 0.''78 to 72.''17, with a mean separation of 14.''76. This is the 17th in this series of papers and covers the period 2010 January 6 through December 20. Also presented are 10 pairs that are resolved for the first time.
Speckle Interferometry at the U.S. Naval Observatory. XXI.
NASA Astrophysics Data System (ADS)
Mason, Brian D.; Hartkopf, William I.; Bredthauer, Greg; Ferguson, Eric W.; Finch, Charlie T.; Kilian, Christopher M.; Rafferty, Theodore J.; Ragan, Tai J.; Wieder, Gary D.
2017-01-01
The results of 2408 intensified CCD observations of double stars, made with the 26 inch refractor of the U.S. Naval Observatory, are presented. Each observation of a system represents a combination of over 2000 short-exposure images. These observations are averaged into 1602 mean relative positions and range in separation from 1.″94 to 107.″41, with a median separation of 11.″96. This is the twenty-first in this series of papers and covers the period from 2015 January 13 through 2015 December 19. Significant instrumentation changes are reported in this paper.
VizieR Online Data Catalog: Velocities in the A2345 cluster (Boschin+, 2010)
NASA Astrophysics Data System (ADS)
Boschin, W.; Barrena, R.; Girardi, M.
2011-08-01
Multi-object spectroscopic observations of A2345 were carried out at the TNG telescope in August 2008. We used DOLORES/MOS with the LR-B Grism 1, yielding a dispersion of 187Å/mm. We used the new E2V CCD, a matrix of 2048x2048 pixels with a pixel size of 13.5um. In total we observed four MOS masks for a total of 147 slits. Total exposure times were of 1h for three masks and 1.5h for the remaining mask. (1 data file).
VizieR Online Data Catalog: Line list for red giants in open clusters (Reddy+, 2015)
NASA Astrophysics Data System (ADS)
Reddy, A. B. S.; Giridhar, S.; Lambert, D. L.
2017-11-01
Observations were carried out during observing runs in 2011 May and November, 2012 November and 2013 March using the Robert G. Tull echelle spectrograph (Tull et al. 1995PASP..107..251T) at the coude focus of the 2.7m Harlan J. Smith telescope located at the McDonald Observatory. On all occasions we employed a 2048x2048 24μm pixel, backside-illuminated, anti-reflection coated CCD as a detector and the 52.67 grooves/mm echelle grating with exposures centred at 5060Å. (2 data files).
Occupational Ocular UV Exposure in Civilian Aircrew.
Chorley, Adrian C; Baczynska, Katarzyna A; Benwell, Martin J; Evans, Bruce J W; Higlett, Michael P; Khazova, Marina; O'Hagan, John B
2016-01-01
Ultraviolet radiation (UVR) increases with altitude; however, there are a number of other factors which may influence ocular exposure during flight. The aim of this study was to assess ocular UVR exposure of pilots in airline and off-shore helicopter operations on different aircraft types and to compare with exposure in a typical office environment. In-flight data were captured on equipment including a CCD array spectroradiometer on five return sector European airline flights and one transatlantic flight from London Gatwick in addition to four helicopter flights from Aberdeen Dyce airport. Further data were collected in an office environment from three workstations during summer and winter months. A wide variation in ocular UVA dose was found during flights. The main factor influencing exposure was the UVR transmission of the windshield, which fell into two distinct profile types. In an aircraft with good UVA blocking properties, ocular exposure was found to be equivalent to office exposure and did not exceed international guideline limits regardless of external conditions or flight time. Most aircraft assessed had poor UVA blocking windshields which resulted in an ocular exposure to the unprotected eye in excess of international guideline limits (up to between 4.5 to 6.5 times greater during one flight). No significant UVB dose was found. Pilots should be warned of the potential high UVA exposure during flight and advised on the use of sunglasses. A windshield labeling system would allow the pilot to tailor their eye protection practices to that particular aircraft.
VizieR Online Data Catalog: Periods of 4-10 Myr old T Tauri members of Orion OB1 (Karim+, 2016)
NASA Astrophysics Data System (ADS)
Karim, M. T.; Stassun, K. G.; Briceno, C.; Vivas, A. K.; Raetz, S.; Mateu, C.; Downes, J. J.; Calvet, N.; Hernandez, J.; Neuhauser, R.; Mugrauer, M.; Takahashi, H.; Tachihara, K.; Chini, R.; Cruz-Dias, G. A.; Aarnio, A.; James, D. J.; Hackstein, M.
2017-02-01
The Astronomia Variability Survey of Orion (CVSO) was carried out at the Llano del Hato National Astronomical Observatory in Venezuela, with the QUEST CCD mosaic camera (8000*8000pixels) on the 1m (clear aperture) Schmidt telescope, with a plate scale of 1.02''/pixel and field of view of 5.4 deg2. This V-, RC-, and IC-band multi-epoch survey, covering ~180deg2 of the Orion OB1 association, spans a time baseline of 12yr, from 1998 December to 2011 February. The 25 Ori cluster was observed by the 0.6/0.9m Schmidt-type telescope at Jena Observatory (Germany), the two 5.9'' telescopes at Observatorio Cerro Armazones (OCA, Chile), and the 1.5m reflector at the Gunma Astronomical Observatory in Japan, over four observing campaigns during the years 2010-2013. The Jena Schmidt-type telescope was equipped with the optical Schmidt Telescope Camera (STK), with an e2v 42-10 2048*2048 detector, yielding a plate scale of 1.55''/pixel and a field of view of 53'*53', thus encompassing most of the cluster. The Jena 50s exposures, all taken through the R filter, were centered on 25 Ori. A total of 8506 individual exposures were obtained in 108 nights. The Gunma 1.5m reflector observations were carried out by obtaining 60s integrations in R with the Gunma Low-resolution Spectrograph and Imager (GLOWS), which has an e2v CCD55-30 1250*1152 pixel detector with a 0.6''/pixel scale, covering a field of view of 12.5'*11.5'. Observations were obtained during four nights in year 2010. The Observatorio Cerro Armazones observations were done in the R band using the RoBoTT (Robotic Bochum TWin Telescope), which consists of twin Takahashi 150mm aperture apochromatic astrographs, each equipped with an Apogee U16M camera with a KAF-16803 4096*4096 pixel CCD, providing a 2.7°*2.7° field of view with 2.37''/pixel scale. The 60s exposures were centered on 25 Ori, spanning an area much larger than the cluster. OCA data were obtained during all YETI seasons. During the nights of 2006 January 8-15, we used the 0.9m telescope with the 8000*8000 pixel MOSAIC imager at the Kitt Peak National Observatory (KPNO), Arizona, USA, to obtain IC-band time-series observations of several regions in the Orion OB1 association, including the 25 Ori cluster in the OB1a subassociation, and fields in the OB1b subassociation, under NOAO program 2005B-0529. (1 data file).
OP09O-OP404-9 Wide Field Camera 3 CCD Quantum Efficiency Hysteresis
NASA Technical Reports Server (NTRS)
Collins, Nick
2009-01-01
The HST/Wide Field Camera (WFC) 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. At the nominal operating temperature of -83C, the QEH feature contrast was typically 0.1-0.2% or less. The behavior was replicated using flight spare detectors. A visible light flat-field (540nm) with a several times full-well signal level can pin the detectors at both optical (600nm) and near-UV (230nm) wavelengths, suppressing the QEH behavior. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. The HST/Wide Field Camera 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. The first observed manifestation of QEH was the presence in a small percentage of flat-field images of a bowtie-shaped contrast that spanned the width of each chip. At the nominal operating temperature of -83C, the contrast observed for this feature was typically 0.1-0.2% or less, though at warmer temperatures contrasts up to 5% (at -50C) have been observed. The bowtie morphology was replicated using flight spare detectors in tests at the GSFC Detector Characterization Laboratory by power cycling the detector while cold. Continued investigation revealed that a clearly-related global QE suppression at the approximately 5% level can be produced by cooling the detector in the dark; subsequent flat-field exposures at a constant illumination show asymptotically increasing response. This QE "pinning" can be achieved with a single high signal flat-field or a series of lower signal flats; a visible light (500-580nm) flat-field with a signal level of several hundred thousand electrons per pixel is sufficient for QE pinning at both optical (600nm) and near-UV (230nm) wavelengths. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. A preliminary estimate of the decay timescale for one detector is that a drop of 0.1-0.2% occurs over a ten day period, indicating that relatively infrequent cal lamp exposures can mitigate the behavior to extremely low levels.
Cryogenic irradiation of an EMCCD for the WFIRST coronagraph: preliminary performance analysis
NASA Astrophysics Data System (ADS)
Bush, Nathan; Hall, David; Holland, Andrew; Burgon, Ross; Murray, Neil; Gow, Jason; Jordan, Douglas; Demers, Richard; Harding, Leon K.; Nemati, Bijan; Hoenk, Michael; Michaels, Darren; Peddada, Pavani
2016-08-01
The Wide Field Infra-Red Survey Telescope (WFIRST) is a NASA observatory scheduled to launch in the next decade that will settle essential questions in exoplanet science. The Wide Field Instrument (WFI) offers Hubble quality imaging over a 0.28 square degree field of view and will gather NIR statistical data on exoplanets through gravitational microlensing. An on-board coronagraph will for the first time perform direct imaging and spectroscopic analysis of exoplanets with properties analogous to those within our own solar system, including cold Jupiters, mini Neptunes and potentially super Earths. The Coronagraph Instrument (CGI) will be required to operate with low signal flux for long integration times, demanding all noise sources are kept to a minimum. The Electron Multiplication (EM)-CCD has been baselined for both the imaging and spectrograph cameras due its ability to operate with sub-electron effective read noise values with appropriate multiplication gain setting. The presence of other noise sources, however, such as thermal dark signal and Clock Induced Charge (CIC), need to be characterized and mitigated. In addition, operation within a space environment will subject the device to radiation damage that will degrade the Charge Transfer Effciency (CTE) of the device throughout the mission lifetime. Irradiation at the nominal instrument operating temperature has the potential to provide the best estimate of performance degradation that will be experienced in-flight, since the final population of silicon defects has been shown to be dependent upon the temperature at which the sensor is irradiated. Here we present initial findings from pre- and post- cryogenic irradiation testing of the e2v CCD201-20 BI EMCCD sensor, baselined for the WFIRST coronagraph instrument. The motivation for irradiation at cryogenic temperatures is discussed with reference to previous investigations of a similar nature. The results are presented in context with those from a previous room temperature irradiation investigation that was performed on a CCD201-20 operated under the same conditions. A key conclusion is that the measured performance degradation for a given proton fluence is seen to measurably differ for the cryogenic case compared to the room temperature equivalent for the conditions of this study.
NASA Astrophysics Data System (ADS)
Hahn, K. E.; Turner, E. C.; Kontak, D. J.; Fayek, M.
2018-02-01
Ancient carbonate rocks commonly contain numerous post-depositional phases (carbonate minerals; quartz) recording successive diagenetic events that can be deciphered and tied to known or inferred geological events using a multi-pronged in situ analytical protocol. The framework voids of large, deep-water microbial carbonate seep-mounds in Arctic Canada (Mesoproterozoic Ikpiarjuk Formation) contain multiple generations of synsedimentary and late cement. An in situ analytical study of the post-seafloor cements used optical and cathodoluminescence petrography, SEM-EDS analysis, fluid inclusion (FI) microthermometry and evaporate mound analysis, LA-ICP-MS analysis, and SIMS δ18O to decipher the mounds' long-term diagenetic history. The six void-filling late cements include, in paragenetic order: inclusion-rich euhedral dolomite (ED), finely crystalline clear dolomite (FCD), hematite-bearing dolomite (HD), coarsely crystalline clear dolomite (CCD), quartz (Q), replacive calcite (RC) and late calcite (LC). Based on the combined analytical results, the following fluid-flow history is defined: (1) ED precipitation by autocementation during shallow burial (fluid 1; Mesoproterozoic); (2) progressive mixing of Ca-rich hydrothermal fluid with the connate fluid, resulting in precipitation of FCD followed by HD (fluid 2; also Mesoproterozoic); (3) precipitation of hydrothermal dolomite (CCD) from high-Ca and K-rich fluids (fluid 3; possibly Mesoproterozoic, but timing unclear); (4) hydrothermal Q precipitation (fluid 4; timing unclear), and (5) RC and LC precipitation from a meteoric-derived water (fluid 5) in or since the Mesozoic. Fluids associated with FCD, HD, and CCD may have been mobilised during deposition of the upper Bylot Supergroup; this time interval was the most tectonically active episode in the region's Mesoproterozoic to Recent history. The entire history of intermittent fluid migration and cement precipitation recorded in seemingly unimportant void-filling mineral phases spans over 1 billion years, and was decipherable only because of the in situ protocol used. The multiple-method in situ analytical protocol employed in this study substantially augments the knowledge of an area's geological history, parts of which cannot be discerned by means other than meticulous study of diagenetic phases, and should become routine in similar studies.
CheMin Instrument Performance and Calibration on Mars
NASA Technical Reports Server (NTRS)
Vaniman, D. T.; Blake, D. F.; Morookian, J. M.; Yen, A. S.; Ming, D. W.; Morris, R. V.; Achilles, C. N.; Bish, D. L.; Chipera, S. J.; Morrison, S. M.;
2013-01-01
The CheMin (Chemistry and Mineralogy) instrument on the Mars Science Laboratory rover Curiosity uses a CCD detector and a Co-anode X-ray tube source to acquire both mineralogy (from the pattern of Co diffraction) and chemical information (from energies of fluoresced X-rays). A key component of the CheMin instrument is the ability to move grains within sample cells during analysis, providing multiple, random grain orientations that disperse diffracted X-ray photons along Debye rings rather than producing discrete Laue spots. This movement is accomplished by piezoelectric vibration of the sample cells. A cryocooler is used to maintain the CCD at a temperature at about -50 C in order to obtain energy resolution better than 250 eV, allowing discrimination of diffracted Co K X-rays from Fe K and other fluorescent X-rays. A detailed description of CheMin is provided in [1]. The CheMin flight model (FM) is mounted within the body of Curiosity and has been operating on Mars since August 6, 2012. An essentially identical sister instrument, the CheMin demonstration model (DM), is operated in a Mars environment chamber at JPL.
NASA Astrophysics Data System (ADS)
Levine, Peter A.; Dawson, Robin M.; Andrews, James T.; Bhaskaran, Mahalingham; Furst, David; Hsueh, Fu-Lung; Meray, Grazyna M.; Sudol, Thomas M.; Swain, Pradyumna K.; Tower, John R.
2003-05-01
Many applications, such as industrial inspection and overhead reconnaissance benefit from line scanning architectures where time delay integration (TDI) significantly improves sensitivity. CCDs are particularly well suited to the TDI architecture since charge is transferred virtually noiselessly down the column. Sarnoff's TDI CCDs have demonstrated extremely high speeds where a 7200 x 64, 8 um pixel device with 120 output ports demonstrated a vertical line transfer rate greater than 800 kHz. The most recent addition to Sarnoff's TDI technology is the implementation of extended dynamic range (XDR) in high speed, back illuminated TDI CCDs. The optical, intrascene dynamic range can be adjusted in the design of the imager with measured dynamic ranges exceeding 2,000,000:1 with no degradation in low light performance. The device provides a piecewise linear response to light where multiple slopes and break points can be set during the CCD design. A description of the device architecture and measured results from fabricated XDR TDI CCDs are presented.
Experimental Modeling of the Impulse Diffraction System with a "White" SR Beam
NASA Astrophysics Data System (ADS)
Fedotov, M. G.; Aleshaev, A. N.
Some matrix detectors (CCD and CIS) have direct X-ray sensitivity and can operate as dispersionless spectrometers with a very large number of elements (106 and more). In the case of the impulse diffraction such detector can simultaneously record a significant number of independent events. In the reading the position and energy of the absorbed X-ray photon may be restored for each event. The mathematical processing of the received data with respect to the Bragg condition can theoretically lead to the coordinates of the events of one fixed energy and to form an analogue of powder diffraction patterns. In this case the registration can be performed on the "white" SR beam for a short time (up to 1 ns or less). The possibility of using of the 2000-element linear CCD ILX511 (Sony) as X-ray dispersionless spectrometer allowed to conduct simulation experiments to obtain diffraction patterns of graphite, boron nitride, boric acid and TNT-hexogen solid detonation products. SR beam from VEPP-3 storage ring was modulated by a mechanical chopper and statistics were provided by a multiple recording with on-line processing.
CCD Detects Two Images In Quick Succession
NASA Technical Reports Server (NTRS)
Janesick, James R.; Collins, Andy
1996-01-01
Prototype special-purpose charge-coupled device (CCD) designed to detect two 1,024 x 1,024-pixel images in rapid succession. Readout performed slowly to minimize noise. CCD operated in synchronism with pulsed laser, stroboscope, or other pulsed source of light to form pairs of images of rapidly moving objects.
Maori, E; Paldi, N; Shafir, S; Kalev, H; Tsur, E; Glick, E; Sela, I
2009-02-01
Colony Collapse Disorder (CCD) has been associated with Israeli acute paralysis virus (IAPV). CCD poses a serious threat to apiculture and agriculture as a whole, due to the consequent inability to provide the necessary amount of bees for pollination of critical crops. Here we report on RNAi-silencing of IAPV infection by feeding bees with double-stranded RNA, as an efficient and feasible way of controlling this viral disease. The association of CCD with IAPV is discussed, as well as the potential of controlling CCD.
SCP -- A Simple CCD Processing Package
NASA Astrophysics Data System (ADS)
Lewis, J. R.
This note describes a small set of programs, written at RGO, which deal with basic CCD frame processing (e.g. bias subtraction, flat fielding, trimming etc.). The need to process large numbers of CCD frames from devices such as FOS or ISIS in order to extract spectra has prompted the writing of routines which will do the basic hack-work with a minimal amount of interaction from the user. Although they were written with spectral data in mind, there are no ``spectrum-specific'' features in the software which means they can be applied to any CCD data.
Software design of control system of CCD side-scatter lidar
NASA Astrophysics Data System (ADS)
Kuang, Zhiqiang; Liu, Dong; Deng, Qian; Zhang, Zhanye; Wang, Zhenzhu; Yu, Siqi; Tao, Zongming; Xie, Chenbo; Wang, Yingjian
2018-03-01
Because of the existence of blind zone and transition zone, the application of backscattering lidar in near-ground is limited. The side-scatter lidar equipped with the Charge Coupled Devices (CCD) can separate the transmitting and receiving devices to avoid the impact of the geometric factors which is exited in the backscattering lidar and, detect the more precise near-ground aerosol signals continuously. Theories of CCD side-scatter lidar and the design of control system are introduced. The visible control of laser and CCD and automatic data processing method of the side-scatter lidar are developed by using the software of Visual C #. The results which are compared with the calibration of the atmospheric aerosol lidar data show that signals from the CCD side- scatter lidar are convincible.
Regulation of transport in the connecting tubule and cortical collecting duct
Staruschenko, Alexander
2012-01-01
The central goal of this overview article is to summarize recent findings in renal epithelial transport, focusing chiefly on the connecting tubule (CNT) and the cortical collecting duct (CCD). Mammalian CCD and CNT are involved in fine tuning of electrolyte and fluid balance through reabsorption and secretion. Specific transporters and channels mediate vectorial movements of water and solutes in these segments. Although only a small percent of the glomerular filtrate reaches the CNT and CCD, these segments are critical for water and electrolyte homeostasis since several hormones, e.g. aldosterone and arginine vasopressin, exert their main effects in these nephron sites. Importantly, hormones regulate the function of the entire nephron and kidney by affecting channels and transporters in the CNT and CCD. Knowledge about the physiological and pathophysiological regulation of transport in the CNT and CCD and particular roles of specific channels/transporters has increased tremendously over the last two decades. Recent studies shed new light on several key questions concerning the regulation of renal transport. Precise distribution patterns of transport proteins in the CCD and CNT will be reviewed, and their physiological roles and mechanisms mediating ion transport in these segments will be also covered. Special emphasis will be given to pathophysiological conditions appearing as a result of abnormalities in renal transport in the CNT and CCD. PMID:23227301
Design of area array CCD image acquisition and display system based on FPGA
NASA Astrophysics Data System (ADS)
Li, Lei; Zhang, Ning; Li, Tianting; Pan, Yue; Dai, Yuming
2014-09-01
With the development of science and technology, CCD(Charge-coupled Device) has been widely applied in various fields and plays an important role in the modern sensing system, therefore researching a real-time image acquisition and display plan based on CCD device has great significance. This paper introduces an image data acquisition and display system of area array CCD based on FPGA. Several key technical challenges and problems of the system have also been analyzed and followed solutions put forward .The FPGA works as the core processing unit in the system that controls the integral time sequence .The ICX285AL area array CCD image sensor produced by SONY Corporation has been used in the system. The FPGA works to complete the driver of the area array CCD, then analog front end (AFE) processes the signal of the CCD image, including amplification, filtering, noise elimination, CDS correlation double sampling, etc. AD9945 produced by ADI Corporation to convert analog signal to digital signal. Developed Camera Link high-speed data transmission circuit, and completed the PC-end software design of the image acquisition, and realized the real-time display of images. The result through practical testing indicates that the system in the image acquisition and control is stable and reliable, and the indicators meet the actual project requirements.
Silicon sample holder for molecular beam epitaxy on pre-fabricated integrated circuits
NASA Technical Reports Server (NTRS)
Hoenk, Michael E. (Inventor); Grunthaner, Paula J. (Inventor); Grunthaner, Frank J. (Inventor)
1994-01-01
The sample holder of the invention is formed of the same semiconductor crystal as the integrated circuit on which the molecular beam expitaxial process is to be performed. In the preferred embodiment, the sample holder comprises three stacked micro-machined silicon wafers: a silicon base wafer having a square micro-machined center opening corresponding in size and shape to the active area of a CCD imager chip, a silicon center wafer micro-machined as an annulus having radially inwardly pointing fingers whose ends abut the edges of and center the CCD imager chip within the annulus, and a silicon top wafer micro-machined as an annulus having cantilevered membranes which extend over the top of the CCD imager chip. The micro-machined silicon wafers are stacked in the order given above with the CCD imager chip centered in the center wafer and sandwiched between the base and top wafers. The thickness of the center wafer is about 20% less than the thickness of the CCD imager chip. Preferably, four titanium wires, each grasping the edges of the top and base wafers, compress all three wafers together, flexing the cantilever fingers of the top wafer to accommodate the thickness of the CCD imager chip, acting as a spring holding the CCD imager chip in place.
Ilg, Andrea; Yu, Qiuju; Schaub, Patrick; Beyer, Peter; Al-Babili, Salim
2010-08-01
Carotenoids are converted by carotenoid cleavage dioxygenases that catalyze oxidative cleavage reactions leading to apocarotenoids. However, apocarotenoids can also be further truncated by some members of this enzyme family. The plant carotenoid cleavage dioxygenase 1 (CCD1) subfamily is known to degrade both carotenoids and apocarotenoids in vitro, leading to different volatile compounds. In this study, we investigated the impact of the rice CCD1 (OsCCD1) on the pigmentation of Golden Rice 2 (GR2), a genetically modified rice variety accumulating carotenoids in the endosperm. For this purpose, the corresponding cDNA was introduced into the rice genome under the control of an endosperm-specific promoter in sense and anti-sense orientations. Despite high expression levels of OsCCD1 in sense plants, pigment analysis revealed carotenoid levels and patterns comparable to those of GR2, pleading against carotenoids as substrates in rice endosperm. In support, similar carotenoid contents were determined in anti-sense plants. To check whether OsCCD1 overexpressed in GR2 endosperm is active, in vitro assays were performed with apocarotenoid substrates. HPLC analysis confirmed the cleavage activity of introduced OsCCD1. Our data indicate that apocarotenoids rather than carotenoids are the substrates of OsCCD1 in planta.
Fabrication of Robust, Flat, Thinned, UV-Imaging CCDs
NASA Technical Reports Server (NTRS)
Grunthaner, Paula; Elliott, Stythe; Jones, Todd; Nikzad, Shouleh
2004-01-01
An improved process that includes a high-temperature bonding subprocess has been developed to enable the fabrication of robust, flat, silicon-based charge-coupled devices (CCDs) for imaging in ultraviolet (UV) light and/or for detecting low-energy charged particles. The CCDs in question are devices on which CCD circuitry has already been formed and have been thinned for backsurface illumination. These CCDs may be delta doped, and aspects of this type of CCD have been described in several prior articles in NASA Tech Briefs. Unlike prior low-temperature bonding subprocesses based on the use of epoxies or waxes, the high-temperature bonding subprocess is compatible with the deltadoping process as well as with other CCD-fabrication processes. The present improved process and its bonding, thinning, and delta-doping subprocesses, are characterized as postfabrication processes because they are undertaken after the fabrication of CCD circuitry on the front side of a full-thickness silicon substrate. In a typical case, it is necessary to reduce the thickness of the CCD to between 10 and 20 m in order to take advantage of back-side illumination and in order to perform delta doping and/or other back-side treatment to enhance the quantum efficiency. In the prior approach to the fabrication of back-side-illuminated CCDs, the thinning subprocess turned each CCD into a free-standing membrane that was fragile and tended to become wrinkled. In the present improved process, prior to thinning and delta doping, a CCD is bonded on its front side to a silicon substrate that has been prefabricated to include cutouts to accommodate subsequent electrical connections to bonding pads on the CCD circuitry. The substrate provides structural support to increase ruggedness and maintain flatness. At the beginning of this process, the back side of a CCD as fabricated on a full-thickness substrate is polished. Silicon nitride is deposited on the back side, opposite the bonding pads on the front side, in order to define a relatively thick frame. The portion of the CCD not covered by the frame is the portion to be thinned by etching.
NASA Astrophysics Data System (ADS)
Li, Xiaoqin; Li, Baian; Chen, Naisong; Huang, Xuxiong; Hua, Xuemin; Leng, Xiangjun
2017-12-01
To compare the flesh quality of large yellow croaker cultured with three different modes, enclosure culture (EC), cage culture with feeding trash fish (CCF) and cage culture with feeding formula diet (CCD), thirty six fish individuals of EC (484.6 ± 79.8 g), CCF (432.7 ± 87.9 g) and CCD (416.9 ± 49.5 g) were sampled to measure body color, flesh water holding capacity, flesh proximate composition, amino acids and fatty acids composition, and collagen and inosinic acid contents. The analysis showed that there was no significant difference in the yellowness of skin and the contents of crude protein and inosinic acid between CCD and EC (P >0.05), and the two modes showed higher values than CCF ( P < 0.05). Most of the amino acids (AA) in flesh were higher in EC than in CCF ( P < 0.05), but CCD showed no difference in AA composition from the other two modes ( P > 0.05). EC and CCD had higher contents of collagen, free AA and lower drip loss than CC ( P < 0.05). In polyunsaturated fatty acids, EC showed significantly higher levels of C20:5n-3 and C22:6n-3 than CCF and CCD ( P < 0.05), but CCD had significantly higher C18:2n-6 than CCF and EC ( P < 0.05). In conclusion, the flesh quality of CCD fish is similar to EC fish, and these two modes have better flesh quality than CCF.
Chevrot, G; Schurhammer, R; Wipff, G
2007-04-28
We report a molecular dynamics study of chlorinated cobalt bis(dicarbollide) anions [(B(9)C(2)H(8)Cl(3))(2)Co](-)"CCD(-)" in octanol and at the octanol-water interface, with the main aim to understand why these hydrophobic species act as strong synergists in assisted liquid-liquid cation extraction. Neat octanol is quite heterogeneous and is found to display dual solvation properties, allowing to well solubilize CCD(-), Cs(+) salts in the form of diluted pairs or oligomers, without displaying aggregation. At the aqueous interface, octanol behaves as an amphiphile, forming either monolayers or bilayers, depending on the initial state and confinement conditions. In biphasic octanol-water systems, CCD(-) anions are found to mainly partition to the organic phase, thus attracting Cs(+) or even more hydrophilic counterions like Eu(3+) into that phase. The remaining CCD(-) anions adsorb at the interface, but are less surface active than at the chloroform interface. Finally, we compare the interfacial behavior of the Eu(BTP)(3)(3+) complex in the absence and in the presence of CCD(-) anions and extractant molecules. It is found that when the CCD(-)'s are concentrated enough, the complex is extracted to the octanol phase. Otherwise, it is trapped at the interface, attracted by water. These results are compared to those obtained with chloroform as organic phase and discussed in the context of synergistic effect of CCD(-) in liquid-liquid extraction, pointing to the importance of dual solvation properties of octanol and of the hydrophobic character of CCD(-) for synergistic extraction of cations.
Study of physical and sound absorbing property of epoxy blended coir dust biocomposite
NASA Astrophysics Data System (ADS)
Nath, G.; Mishra, S. P.
2016-09-01
Reinforcement biocomposite has gained more attention recently due to its low cost, abundantly availability, low density, specific properties, easy method of separation, enhanced energy recovery, CO2 neutrality, biodegradability and recyclable in nature. As a waste product of coconut fruit, the coconut coir dust (CCD) obtained from the coconut husk. The biocomposite material prepared from the CCD modified with the proper blended solution with the help of ultrasonic technique. The study of adiabatic compressibility of acetone / water (70/30) worth its blending property for bleaching of CCD. The biocomposite material of CCD was prepared with epoxy resin. The different physical properties such as sound absorption coefficient, thermal conductivity and electrical conductivity were measured. The morphological study of biocomposite and measurement of sound absorption coefficient shows good evidence of sound absorbing characteristics of biocomposite of CCD. The sound absorption property of composite material shows a significant result where as the thermal conductivity and electrical conductivity executes a weak result. Thus biocomposite of CCD can acts as a good sound absorber and band conductor of heat and electric current.
Driving techniques for high frame rate CCD camera
NASA Astrophysics Data System (ADS)
Guo, Weiqiang; Jin, Longxu; Xiong, Jingwu
2008-03-01
This paper describes a high-frame rate CCD camera capable of operating at 100 frames/s. This camera utilizes Kodak KAI-0340, an interline transfer CCD with 640(vertical)×480(horizontal) pixels. Two output ports are used to read out CCD data and pixel rates approaching 30 MHz. Because of its reduced effective opacity of vertical charge transfer registers, interline transfer CCD can cause undesired image artifacts, such as random white spots and smear generated in the registers. To increase frame rate, a kind of speed-up structure has been incorporated inside KAI-0340, then it is vulnerable to a vertical stripe effect. The phenomena which mentioned above may severely impair the image quality. To solve these problems, some electronic methods of eliminating these artifacts are adopted. Special clocking mode can dump the unwanted charge quickly, then the fast readout of the images, cleared of smear, follows immediately. Amplifier is used to sense and correct delay mismatch between the dual phase vertical clock pulses, the transition edges become close to coincident, so vertical stripes disappear. Results obtained with the CCD camera are shown.
A 128K-bit CCD buffer memory system
NASA Technical Reports Server (NTRS)
Siemens, K. H.; Wallace, R. W.; Robinson, C. R.
1976-01-01
A prototype system was implemented to demonstrate that CCD's can be applied advantageously to the problem of low power digital storage and particularly to the problem of interfacing widely varying data rates. 8K-bit CCD shift register memories were used to construct a feasibility model 128K-bit buffer memory system. Peak power dissipation during a data transfer is less than 7 W., while idle power is approximately 5.4 W. The system features automatic data input synchronization with the recirculating CCD memory block start address. Descriptions are provided of both the buffer memory system and a custom tester that was used to exercise the memory. The testing procedures and testing results are discussed. Suggestions are provided for further development with regards to the utilization of advanced versions of CCD memory devices to both simplified and expanded memory system applications.
Speckle Interferometry at the Blanco and SOAR Telescopes in 2008 and 2009
NASA Technical Reports Server (NTRS)
Tokovinin, Andrei; Mason, Brian D.; Hartkopf, William I.
2010-01-01
The results of speckle interferometric measurements of binary and multiple stars conducted in 2008 and 2009 at the Blanco and Southern Astrophysical Research (SOAR) 4 m telescopes in Chile are presented. A tot al of 1898 measurements of 1189 resolved pairs or sub-systems and 394 observations of 285 un-resolved targets are listed. We resolved for the first time 48 new pairs, 21 of which are new sub-systems in close visual multiple stars. Typical internal measurement precision is 0.3 mas in both coordinates, typical companion detection capability is delta m approximately 4.2 at 0.15 degree separation. These data were obtained with a new electron-multiplication CCD camera; data processing is described in detail, including estimation of magnitude difference, observational errors, detection limits, and analysis of artifacts. We comment on some newly discovered pairs and objects of special interest.
CICADA -- Configurable Instrument Control and Data Acquisition
NASA Astrophysics Data System (ADS)
Young, Peter J.; Roberts, William H.; Sebo, Kim M.
CICADA (Young et al. 1997) is a multi-process, distributed application for the control of astronomical data acquisition systems. It comprises elements that control the operation of, and data flow from CCD camera systems; and the operation of telescope instrument control systems. CICADA can be used to dynamically configure support for astronomical instruments that can be made up of multiple cameras and multiple instrument controllers. Each camera is described by a hierarchy of parts that are each individually configured and linked together. Most of CICADA is written in C++ and much of the configurability of CICADA comes from the use of inheritance and polymorphism. An example of a multiple part instrument configuration -- a wide field imager (WFI) -- is described here. WFI, presently under construction, is made up of eight 2k x 4k CCDs with dual SDSU II controllers and will be used at Siding Spring's ANU 40in and AAO 3.9m telescopes.
SPECKLE INTERFEROMETRY AT THE BLANCO AND SOAR TELESCOPES IN 2008 AND 2009
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tokovinin, Andrei; Mason, Brian D.; Hartkopf, William I.
2010-02-15
The results of speckle interferometric measurements of binary and multiple stars conducted in 2008 and 2009 at the Blanco and SOAR 4 m telescopes in Chile are presented. A total of 1898 measurements of 1189 resolved pairs or sub-systems and 394 observations of 285 un-resolved targets are listed. We resolved for the first time 48 new pairs, 21 of which are new sub-systems in close visual multiple stars. Typical internal measurement precision is 0.3 mas in both coordinates, typical companion detection capability is {delta}m {approx} 4.2 at 0.''15 separation. These data were obtained with a new electron-multiplication CCD camera; datamore » processing is described in detail, including estimation of magnitude difference, observational errors, detection limits, and analysis of artifacts. We comment on some newly discovered pairs and objects of special interest.« less
Lucas, J E; Richter, L M; Daelmans, B
2018-01-01
An estimated 43% of children younger than 5 years of age are at elevated risk of failing to achieve their human potential. In response, the World Health Organization and UNICEF developed Care for Child Development (CCD), based on the science of child development, to improve sensitive and responsive caregiving and promote the psychosocial development of young children. In 2015, the World Health Organization and UNICEF identified sites where CCD has been implemented and sustained. The sites were surveyed, and responses were followed up by phone interviews. Project reports provided information on additional sites, and a review of published studies was undertaken to document the effectiveness of CCD for improving child and family outcomes, as well as its feasibility for implementation in resource-constrained communities. The inventory found that CCD had been integrated into existing services in diverse sectors in 19 countries and 23 sites, including child survival, health, nutrition, infant day care, early education, family and child protection and services for children with disabilities. Published and unpublished evaluations have found that CCD interventions can improve child development, growth and health, as well as responsive caregiving. It has also been reported to reduce maternal depression, a known risk factor for poor pregnancy outcomes and poor child health, growth and development. Although CCD has expanded beyond initial implementation sites, only three countries reported having national policy support for integrating CCD into health or other services. Strong interest exists in many countries to move beyond child survival to protect and support optimal child development. The United Nations Sustainable Development Goals depend on children realizing their potential to build healthy and emotionally, cognitively and socially competent future generations. More studies are needed to guide the integration of the CCD approach under different conditions. Nevertheless, the time is right to provide for the scale-up of CCD as part of services for families and children. © 2017 The Authors. Child: Care, Health and Development Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Zeng, Yi; Han, Xue-bing; Yang, Dong-shang; Gui, Li-jia; Zhao, Xiao-xiang; Si, Fu-qi
2016-03-01
A space-borne differential optical absorption spectrometer is a high precision aerospace optical remote sensor. It obtains the hyper-spectral,high spatial resolution radiation information by using the spectrometer with CCD(Charge Coupled Device)array detectors. Since a few CCDs are used as the key detector, the performance of the entire instrument is greatly affected by working condition of CCDs. The temperature of CCD modules has a great impact on the instrument measurement accuracy. It requires strict temperature control. The selection of the thermal conductive filler sticking CCD to the radiator is important in the CCD thermal design. Besides,due tothe complex and compact structure, it needs to take into account the anti-pollution of the optical system. Therefore, it puts forward high requirements on the selection of the conductive filler. In this paper, according to the structure characteristics of the CCD modules and the distribution of heat consumption, the thermal analysis tool I-DEAS/TMG is utilized to compute and simulate the temperature level of the CCD modules, while filling in thermal grease and thermal pad respectively. The temperature distribution of CCD heat dissipation in typical operating conditions is obtained. In addition, the heat balance test was carried out under the condition of two kinds of thermal conductive fillers. The thermal control of CCD was tested under various conditions, and the results were compared with the results of thermal analysis. The results show that there are some differences in thermal performance between the two kinds of thermal conductive fillers. Although they both can meet the thermal performance requirements of the instrument, either would be chosen taking account of other conditions and requirements such as anti-pollution and insulation. The content and results of this paper will be a good reference for the thermal design of the CCD in the aerospace optical payload.
Toolkit for testing scientific CCD cameras
NASA Astrophysics Data System (ADS)
Uzycki, Janusz; Mankiewicz, Lech; Molak, Marcin; Wrochna, Grzegorz
2006-03-01
The CCD Toolkit (1) is a software tool for testing CCD cameras which allows to measure important characteristics of a camera like readout noise, total gain, dark current, 'hot' pixels, useful area, etc. The application makes a statistical analysis of images saved in files with FITS format, commonly used in astronomy. A graphical interface is based on the ROOT package, which offers high functionality and flexibility. The program was developed in a way to ensure future compatibility with different operating systems: Windows and Linux. The CCD Toolkit was created for the "Pie of the Sky" project collaboration (2).
Low temperature multi-alkali photocathode processing technique for sealed intensified CCD tubes
NASA Technical Reports Server (NTRS)
Doliber, D. L.; Dozier, E. E.; Wenzel, H.; Beaver, E. A.; Hier, R. G.
1989-01-01
A low temperature photocathode process has been used to fabricate an intensified CCD visual photocathode image tube, by incorporating a thinned, backside-illumined CCD as the target anode of a digicon tube of Hubble Space Telescope (HST) design. The CCD digicon tube employs the HST's sodium bialkali photocathode and MgF2 substrate, thereby allowing a direct photocathode quantum efficiency comparison between photocathodes produced by the presently employed low temperature process and those of the conventional high temperature process. Attention is given to the processing chamber used, as well as the details of gas desorption and photocathode processing.
NASA Astrophysics Data System (ADS)
Granero, Luis; Ferreira, Carlos; Zalevsky, Zeev; García, Javier; Micó, Vicente
2016-07-01
Single-Exposure Super-Resolved Interferometric Microscopy (SESRIM) reports on a way to achieve one-dimensional (1-D) superresolved imaging in digital holographic microscopy (DHM) by a single illumination shot and digital recording. SESRIM provides color-coded angular multiplexing of the accessible sample's range of spatial frequencies and it allows their recording in a single CCD (color or monochrome) snapshot by adding 3 RGB coherent reference beams at the output plane. In this manuscript, we extend the applicability of SESRIM to the field of digital in-line holographic microscopy (DIHM), that is, working without lenses. As consequence of the in-line configuration, an additional restriction concerning the object field of view (FOV) must be imposed to the technique. Experimental results are reported for both a synthetic object (USAF resolution test target) and a biological sample (swine sperm sample) validating this new kind of superresolution imaging method named as lensless SESRIM (L-SESRIM).
Photon Counting Imaging with an Electron-Bombarded Pixel Image Sensor
Hirvonen, Liisa M.; Suhling, Klaus
2016-01-01
Electron-bombarded pixel image sensors, where a single photoelectron is accelerated directly into a CCD or CMOS sensor, allow wide-field imaging at extremely low light levels as they are sensitive enough to detect single photons. This technology allows the detection of up to hundreds or thousands of photon events per frame, depending on the sensor size, and photon event centroiding can be employed to recover resolution lost in the detection process. Unlike photon events from electron-multiplying sensors, the photon events from electron-bombarded sensors have a narrow, acceleration-voltage-dependent pulse height distribution. Thus a gain voltage sweep during exposure in an electron-bombarded sensor could allow photon arrival time determination from the pulse height with sub-frame exposure time resolution. We give a brief overview of our work with electron-bombarded pixel image sensor technology and recent developments in this field for single photon counting imaging, and examples of some applications. PMID:27136556
NASA Technical Reports Server (NTRS)
Tull, Robert G.; Macqueen, Phillip J.; Sneden, Christopher; Lambert, David L.
1995-01-01
A new high-resolution cross-dispersed echelle spectrometer has been installed at the coude focus of the McDonald Observatory 2.7-m telescope. Its primary goal was simultaneously to gather spectra over as much of the spectral range 3400 A to 1 micrometer as practical, at a resolution R identical with lambda/Delta lambda which approximately = 60,000 with signal-to-noise ratio of approximately 100 for stars down to magnitude 11, using 1-h exposures. In the instrument as built, two exposures are all that are needed to cover the full range. Featuring a white-pupil design, fused silica prism cross disperser, and folded Schmidt camera with a Tektronix 2048x2048 CCD used at either of two foci, it has been in regularly scheduled operation since 1992 April. Design details and performance are described.
Regulation of transport in the connecting tubule and cortical collecting duct.
Staruschenko, Alexander
2012-04-01
The central goal of this overview article is to summarize recent findings in renal epithelial transport,focusing chiefly on the connecting tubule (CNT) and the cortical collecting duct (CCD).Mammalian CCD and CNT are involved in fine-tuning of electrolyte and fluid balance through reabsorption and secretion. Specific transporters and channels mediate vectorial movements of water and solutes in these segments. Although only a small percent of the glomerular filtrate reaches the CNT and CCD, these segments are critical for water and electrolyte homeostasis since several hormones, for example, aldosterone and arginine vasopressin, exert their main effects in these nephron sites. Importantly, hormones regulate the function of the entire nephron and kidney by affecting channels and transporters in the CNT and CCD. Knowledge about the physiological and pathophysiological regulation of transport in the CNT and CCD and particular roles of specific channels/transporters has increased tremendously over the last two decades.Recent studies shed new light on several key questions concerning the regulation of renal transport.Precise distribution patterns of transport proteins in the CCD and CNT will be reviewed, and their physiological roles and mechanisms mediating ion transport in these segments will also be covered. Special emphasis will be given to pathophysiological conditions appearing as a result of abnormalities in renal transport in the CNT and CCD. © 2012 American Physiological Society. Compr Physiol 2:1491-1539, 2012.
Cervical spine dysfunction signs and symptoms in individuals with temporomandibular disorder.
Weber, Priscila; Corrêa, Eliane Castilhos Rodrigues; Ferreira, Fabiana dos Santos; Soares, Juliana Corrêa; Bolzan, Geovana de Paula; Silva, Ana Maria Toniolo da
2012-01-01
To study the frequency of cervical spine dysfunction (CCD) signs and symptoms in subjects with and without temporomandibular disorder (TMD) and to assess the craniocervical posture influence on TMD and CCD coexistence. Participants were 71 women (19 to 35 years), assessed about TMD presence; 34 constituted the TMD group (G1) and 37 comprised the group without TMD (G2). The CCD was evaluated through the Craniocervical Dysfunction Index and the Cervical Mobility Index. Subjects were also questioned about cervical pain. Craniocervical posture was assessed by cephalometric analysis. There was no difference in the craniocervical posture between groups. G2 presented more mild CCD frequency and less moderate and severe CCD frequency (p=0.01). G1 presented higher percentage of pain during movements (p=0.03) and pain during cervical muscles palpation (p=0.01) compared to G2. Most of the TMD patients (88.24%) related cervical pain with significant difference when compared to G2 (p=0.00). Craniocervical posture assessment showed no difference between groups, suggesting that postural alterations could be more related to the CCD. Presence of TMD resulted in higher frequency of cervical pain symptom. Thus the coexistence of CCD and TMD signs and symptoms appear to be more related to the common innervations of the trigeminocervical complex and hyperalgesia of the TMD patients than to craniocervical posture deviations.
Instructional Staff Salary and Benefits Spending: 1991-2011. Data Point. NCES 2016-156
ERIC Educational Resources Information Center
Malkus, Nat; Hoyer, Kathleen Mulvaney
2016-01-01
This report uses expenditure data from the Common Core of Data (CCD) "National Public Education Financial Survey (NPEFS)" for fiscal years 1991 to 2011 and instructional staff data from the CCD "State Nonfiscal Survey of Public Elementary/Secondary Education" for school years 1990-91 to 2010-11. The CCD annually collects fiscal…
Yao, Tao; Yin, Shi-Min; Xiangli, Bin; Lü, Qun-Bo
2010-06-01
Based on in-depth analysis of the relative radiation scaling theorem and acquired scaling data of pixel response nonuniformity correction of CCD (charge-coupled device) in spaceborne visible interferential imaging spectrometer, a pixel response nonuniformity correction method of CCD adapted to visible and infrared interferential imaging spectrometer system was studied out, and it availably resolved the engineering technical problem of nonuniformity correction in detector arrays for interferential imaging spectrometer system. The quantitative impact of CCD nonuniformity on interferogram correction and recovery spectrum accuracy was given simultaneously. Furthermore, an improved method with calibration and nonuniformity correction done after the instrument is successfully assembled was proposed. The method can save time and manpower. It can correct nonuniformity caused by other reasons in spectrometer system besides CCD itself's nonuniformity, can acquire recalibration data when working environment is changed, and can also more effectively improve the nonuniformity calibration accuracy of interferential imaging
A CCD experimental platform for large telescope in Antarctica based on FPGA
NASA Astrophysics Data System (ADS)
Zhu, Yuhua; Qi, Yongjun
2014-07-01
The CCD , as a detector , is one of the important components of astronomical telescopes. For a large telescope in Antarctica, a set of CCD detector system with large size, high sensitivity and low noise is indispensable. Because of the extremely low temperatures and unattended, system maintenance and software and hardware upgrade become hard problems. This paper introduces a general CCD controller experiment platform, using Field programmable gate array FPGA, which is, in fact, a large-scale field reconfigurable array. Taking the advantage of convenience to modify the system, construction of driving circuit, digital signal processing module, network communication interface, control algorithm validation, and remote reconfigurable module may realize. With the concept of integrated hardware and software, the paper discusses the key technology of building scientific CCD system suitable for the special work environment in Antarctica, focusing on the method of remote reconfiguration for controller via network and then offering a feasible hardware and software solution.
Atac, M.; McKay, T.A.
1998-04-21
An imaging system is provided for direct detection of x-rays from an irradiated biological tissue. The imaging system includes an energy source for emitting x-rays toward the biological tissue and a charge coupled device (CCD) located immediately adjacent the biological tissue and arranged transverse to the direction of irradiation along which the x-rays travel. The CCD directly receives and detects the x-rays after passing through the biological tissue. The CCD is divided into a matrix of cells, each of which individually stores a count of x-rays directly detected by the cell. The imaging system further includes a pattern generator electrically coupled to the CCD for reading a count from each cell. A display device is provided for displaying an image representative of the count read by the pattern generator from the cells of the CCD. 13 figs.
Atac, Muzaffer; McKay, Timothy A.
1998-01-01
An imaging system is provided for direct detection of x-rays from an irradiated biological tissue. The imaging system includes an energy source for emitting x-rays toward the biological tissue and a charge coupled device (CCD) located immediately adjacent the biological tissue and arranged transverse to the direction of irradiation along which the x-rays travel. The CCD directly receives and detects the x-rays after passing through the biological tissue. The CCD is divided into a matrix of cells, each of which individually stores a count of x-rays directly detected by the cell. The imaging system further includes a pattern generator electrically coupled to the CCD for reading a count from each cell. A display device is provided for displaying an image representative of the count read by the pattern generator from the cells of the CCD.
NASA Astrophysics Data System (ADS)
Villanueva, Steven; Gaudi, B. Scott; Pogge, Richard; Stassun, Keivan G.; Eastman, Jason; Trueblood, Mark; Trueblood, Pat
2018-01-01
The DEdicated MONitor of EXotransits and Transients (DEMONEXT) is a 20 inch (0.5-m) robotic telescope that has been in operation since May 2016. Fully automated, DEMONEXT has observed over 150 transits of exoplanet candidates for the KELT survey, including confirmation observations of KELT-20b. DEMONEXT achieves 2-4 mmag precision with unbinned, 20-120 second exposures, on targets orbiting V<13 host stars. Millimagnitude precision can be achieved by binning the transits on 5-6 minute timescales. During observations of 8 hours with hundreds of consecutive exposures, DEMONEXT maintains sub-pixel (<0.5 pixels) target position stability on the CCD during good observing conditions, with degraded performance during poor observing conditions (<1 pixel). DEMONEXT achieves 1% photometry on targets with V<17 in 5 minute exposures, with detection limits of V~21. In addition to the 150 transits observed by DEMONEXT, 50 supernovae and transients haven been observed for the ASAS-SN supernovae group, as well as time-series observations of Galactic microlensing, active galactic nuclei, stellar variability, and stellar rotation.
Isolation Mounting for Charge-Coupled Devices
NASA Technical Reports Server (NTRS)
Goss, W. C.; Salomon, P. M.
1985-01-01
CCD's suspended by wires under tension. Remote thermoelectric cooling of charge coupled device allows vibration isolating mounting of CCD assembly alone, without having to suspend entire mass and bulk of thermoelectric module. Mounting hardware simple and light. Developed for charge-coupled devices (CCD's) in infrared telescope support adaptable to sensors in variety of environments, e.g., sensors in nuclear reactors, engine exhausts and plasma chambers.
Test of CCD Precision Limits for Differential Photometry
NASA Technical Reports Server (NTRS)
Borucki, W. J.; Dunham, E. W.; Wei, M. Z.; Robinson, L. B.; Ford, C. H.; Granados, A. F.
1995-01-01
Results of tests to demonstrate the very high differential-photometric stability of CCD light sensors are presented. The measurements reported here demonstrate that in a controlled laboratory environment, a front-illuminated CCD can provide differential-photometric measurements with reproducible precision approaching one part in 105. Practical limitations to the precision of differential-photometric measurements with CCDs and implications for spaceborne applications are discussed.
Common Core of Data (CCD): School Years 1996-1997 through 2000-2001. [CD-ROM].
ERIC Educational Resources Information Center
National Center for Education Statistics (ED), Washington, DC.
The Common Core of Data (CCD) is NCES's primary database on elementary and secondary public education in the United States. CCD is a comprehensive, annual, national statistical database of all elementary and secondary schools and school districts, which contains data that are comparable across all states. The 50 states and the District of Columbia…
NASA Astrophysics Data System (ADS)
Mugrauer, M.
2016-03-01
The Cassegrain-Teleskop-Kamera (CTK-II) and the Refraktor-Teleskop-Kamera (RTK) are two CCD-imagers which are operated at the 25 cm Cassegrain and 20 cm refractor auxiliary telescopes of the University Observatory Jena. This article describes the main characteristics of these instruments. The properties of the CCD-detectors, the astrometry, the image quality, and the detection limits of both CCD-cameras, as well as some results of ongoing observing projects, carried out with these instruments, are presented. Based on observations obtained with telescopes of the University Observatory Jena, which is operated by the Astrophysical Institute of the Friedrich-Schiller-University.
CCD charge collection efficiency and the photon transfer technique
NASA Technical Reports Server (NTRS)
Janesick, J.; Klaasen, K.; Elliott, T.
1985-01-01
The charge-coupled device (CCD) has shown unprecendented performance as a photon detector in the areas of spectral response, charge transfer, and readout noise. Recent experience indicates, however, that the full potential for the CCD's charge collection efficiency (CCE) lies well beyond that which is realized in currently available devices. A definition of CCE performance is presented and a standard test tool (the photon transfer technique) for measuring and optimizing this important CCD parameter is introduced. CCE characteristics for different types of CCDs are compared; the primary limitations in achieving high CCE performance are discussed, and the prospects for future improvement are outlined.
Howard, Richard; Finn, Peter; Jose, Paul; Gallagher, Jennifer
2011-12-16
This study tested the hypothesis that adolescent-onset alcohol abuse (AOAA) would both mediate and moderate the effect of childhood conduct disorder on antisocial behaviour in late adolescence and early adulthood. A sample comprising 504 young men and women strategically recruited from the community were grouped using the criteria of the Diagnostic and Statistical Manual (DSM-IV, American Psychiatric Association. (1994). Diagnostic and statistical manual of mental disorders (4th ed.). Washington, DC: APA), as follows: neither childhood conduct disorder (CCD) nor alcohol abuse/dependence; CCD but no alcohol abuse or dependence; alcohol abuse/dependence but no CCD; both CCD and alcohol abuse/dependence. The outcome measure was the sum of positive responses to 55 interview items capturing a variety of antisocial behaviours engaged in since age 15. Severity of lifetime alcohol-related and CCD problems served as predictor variables in regression analysis. Antisocial behaviour problems were greatest in individuals with a history of co-occurring conduct disorder (CD) and alcohol abuse/dependence. While CCD was strongly predictive of adult antisocial behaviour, this effect was both mediated and moderated (exacerbated) by AOAA.
NASA Astrophysics Data System (ADS)
Garza, Alejandro J.; Bulik, Ireneusz W.; Alencar, Ana G. Sousa; Sun, Jianwei; Perdew, John P.; Scuseria, Gustavo E.
2016-04-01
Contrary to standard coupled cluster doubles (CCD) and Brueckner doubles (BD), singlet-paired analogues of CCD and BD (denoted here as CCD0 and BD0) do not break down when static correlation is present, but neglect substantial amounts of dynamic correlation. In fact, CCD0 and BD0 do not account for any contributions from multielectron excitations involving only same-spin electrons at all. We exploit this feature to add - without introducing double counting, self-interaction, or increase in cost - the missing correlation to these methods via meta-GGA (generalised gradient approximation) density functionals (Tao-Perdew-Staroverov-Scuseria and strongly constrained and appropriately normed). Furthermore, we improve upon these CCD0+DFT blends by invoking range separation: the short- and long-range correlations absent in CCD0/BD0 are evaluated with density functional theory and the direct random phase approximation, respectively. This corrects the description of long-range van der Waals forces. Comprehensive benchmarking shows that the combinations presented here are very accurate for weakly correlated systems, while also providing a reasonable description of strongly correlated problems without resorting to symmetry breaking.
NASA Astrophysics Data System (ADS)
von Zanthier, Christoph; Holl, Peter; Kemmer, Josef; Lechner, Peter; Maier, B.; Soltau, Heike; Stoetter, R.; Braeuninger, Heinrich W.; Dennerl, Konrad; Haberl, Frank; Hartmann, R.; Hartner, Gisela D.; Hippmann, H.; Kastelic, E.; Kink, W.; Krause, N.; Meidinger, Norbert; Metzner, G.; Pfeffermann, Elmar; Popp, M.; Reppin, Claus; Stoetter, Diana; Strueder, Lothar; Truemper, Joachim; Weber, U.; Carathanassis, D.; Engelhard, S.; Gebhart, Th.; Hauff, D.; Lutz, G.; Richter, R. H.; Seitz, H.; Solc, P.; Bihler, Edgar; Boettcher, H.; Kendziorra, Eckhard; Kraemer, J.; Pflueger, Bernhard; Staubert, Ruediger
1998-04-01
The concept and performance of the fully depleted pn- junction CCD system, developed for the European XMM- and the German ABRIXAS-satellite missions for soft x-ray imaging and spectroscopy in the 0.1 keV to 15 keV photon range, is presented. The 58 mm X 60 mm large pn-CCD array uses pn- junctions for registers and for the backside instead of MOS registers. This concept naturally allows to fully deplete the detector volume to make it an efficient detector to photons with energies up to 15 keV. For high detection efficiency in the soft x-ray region down to 100 eV, an ultrathin pn-CCD backside deadlayer has been realized. Each pn-CCD-channel is equipped with an on-chip JFET amplifier which, in combination with the CAMEX-amplifier and multiplexing chip, facilitates parallel readout with a pixel read rate of 3 MHz and an electronic noise floor of ENC < e-. With the complete parallel readout, very fast pn-CCD readout modi can be implemented in the system which allow for high resolution photon spectroscopy of even the brightest x-ray sources in the sky.
Howard, Richard; Finn, Peter; Jose, Paul; Gallagher, Jennifer
2012-01-01
This study tested the hypothesis that adolescent-onset alcohol abuse (AOAA) would both mediate and moderate the effect of childhood conduct disorder on antisocial behaviour in late adolescence and early adulthood. A sample comprising 504 young men and women strategically recruited from the community were grouped using the criteria of the Diagnostic and Statistical Manual (DSM-IV, American Psychiatric Association. (1994). Diagnostic and statistical manual of mental disorders (4th ed.). Washington, DC: APA), as follows: neither childhood conduct disorder (CCD) nor alcohol abuse/dependence; CCD but no alcohol abuse or dependence; alcohol abuse/dependence but no CCD; both CCD and alcohol abuse/dependence. The outcome measure was the sum of positive responses to 55 interview items capturing a variety of antisocial behaviours engaged in since age 15. Severity of lifetime alcohol-related and CCD problems served as predictor variables in regression analysis. Antisocial behaviour problems were greatest in individuals with a history of co-occurring conduct disorder (CD) and alcohol abuse/dependence. While CCD was strongly predictive of adult antisocial behaviour, this effect was both mediated and moderated (exacerbated) by AOAA. PMID:23459369
NASA Astrophysics Data System (ADS)
Waltham, N.; Beardsley, S.; Clapp, M.; Lang, J.; Jerram, P.; Pool, P.; Auker, G.; Morris, D.; Duncan, D.
2017-11-01
Solar Dynamics Observatory (SDO) is imaging the Sun in many wavelengths near simultaneously and with a resolution ten times higher than the average high-definition television. In this paper we describe our innovative systems approach to the design of the CCD cameras for two of SDO's remote sensing instruments, the Atmospheric Imaging Assembly (AIA) and the Helioseismic and Magnetic Imager (HMI). Both instruments share use of a custom-designed 16 million pixel science-grade CCD and common camera readout electronics. A prime requirement was for the CCD to operate with significantly lower drive voltages than before, motivated by our wish to simplify the design of the camera readout electronics. Here, the challenge lies in the design of circuitry to drive the CCD's highly capacitive electrodes and to digitize its analogue video output signal with low noise and to high precision. The challenge is greatly exacerbated when forced to work with only fully space-qualified, radiation-tolerant components. We describe our systems approach to the design of the AIA and HMI CCD and camera electronics, and the engineering solutions that enabled us to comply with both mission and instrument science requirements.
pnCCD for photon detection from near-infrared to X-rays
NASA Astrophysics Data System (ADS)
Meidinger, Norbert; Andritschke, Robert; Hartmann, Robert; Herrmann, Sven; Holl, Peter; Lutz, Gerhard; Strüder, Lothar
2006-09-01
A pnCCD is a special type of charge-coupled device developed for spectroscopy and imaging of X-rays with high time resolution and quantum efficiency. Its most famous application is the operation on the XMM-Newton satellite, an X-ray astronomy mission that was launched by the European space agency in 1999. The excellent performance of the focal plane camera has been maintained for more than 6 years in orbit. The energy resolution in particular has shown hardly any degradation since launch. In order to satisfy the requirements of future X-ray astronomy missions as well as those of ground-based experiments, a new type of pnCCD has been developed. This ‘frame-store pnCCD’ shows an enhanced performance compared to the XMM-Newton type of pnCCD. Now, more options in device design and operation are available to tailor the detector to its respective application. Part of this concept is a programmable analog signal processor, which has been developed for the readout of the CCD signals. The electronic noise of the new detector has a value of only 2 electrons equivalent noise charge (ENC), which is less than half of the figure achieved for the XMM-Newton-type pnCCD. The energy resolution for the Mn-Kα line at 5.9 keV is approximately 130 eV FWHM. We have close to 100% quantum efficiency for both low- and high-energy photon detection (e.g. the C-K line at 277 eV, and the Ge-Kα line at 10 keV, respectively). Very high frame rates of 1000 images/s have been achieved due to the ultra-fast readout accomplished by the parallel architecture of the pnCCD and the analog signal processor. Excellent spectroscopic performance is shown even at the relatively high operating temperature of -25 °C that can be achieved by a Peltier cooler. The applications of the low-noise and fast pnCCD detector are not limited to the detection of X-rays. With an anti-reflective coating deposited on the photon entrance window, we achieve high quantum efficiency also for near-infrared and optical photons. A novel type of pnCCD is in preparation, which allows single optical photon counting. This feature is accomplished by implementation of an avalanche-type amplifier in the pnCCD concept.
NASA Astrophysics Data System (ADS)
Garza, Alejandro J.
Perhaps the most important approximations to the electronic structure problem in quantum chemistry are those based on coupled cluster and density functional theories. Coupled cluster theory has been called the ``gold standard'' of quantum chemistry due to the high accuracy that it achieves for weakly correlated systems. Kohn-Sham density functionals based on semilocal approximations are, without a doubt, the most widely used methods in chemistry and material science because of their high accuracy/cost ratio. The root of the success of coupled cluster and density functionals is their ability to efficiently describe the dynamic part of the electron correlation. However, both traditional coupled cluster and density functional approximations may fail catastrophically when substantial static correlation is present. This severely limits the applicability of these methods to a plethora of important chemical and physical problems such as, e.g., the description of bond breaking, transition states, transition metal-, lanthanide- and actinide-containing compounds, and superconductivity. In an attempt to tackle this problem, nonstandard (single-reference) coupled cluster-based techniques that aim to describe static correlation have been recently developed: pair coupled cluster doubles (pCCD) and singlet-paired coupled cluster doubles (CCD0). The ability to describe static correlation in pCCD and CCD0 comes, however, at the expense of important amounts of dynamic correlation so that the high accuracy of standard coupled cluster becomes unattainable. Thus, the reliable and efficient description of static and dynamic correlation in a simultaneous manner remains an open problem for quantum chemistry and many-body theory in general. In this thesis, different ways to combine pCCD and CCD0 with density functionals in order to describe static and dynamic correlation simultaneously (and efficiently) are explored. The combination of wavefunction and density functional methods has a long history in quantum chemistry (practical implementations have appeared in the literature since the 1970s). However, this kind of techniques have not achieved widespread use due to problems such as double counting of correlation and the symmetry dilemma--the fact that wavefunction methods respect the symmetries of Hamiltonian, while modern functionals are designed to work with broken symmetry densities. Here, particular mathematical features of pCCD and CCD0 are exploited to avoid these problems in an efficient manner. The two resulting families of approximations, denoted as pCCD+DFT and CCD0+DFT, are shown to be able to describe static and dynamic correlation in standard benchmark calculations. Furthermore, it is also shown that CCD0+DFT lends itself to combination with correlation from the direct random phase approximation (dRPA). Inclusion of dRPA in the long-range via the technique of range-separation allows for the description of dispersion correlation, the remaining part of the correlation. Thus, when combined with the dRPA, CCD0+DFT can account for all three-types of electron correlation that are necessary to accurately describe molecular systems. Lastly, applications of CCD0+DFT to actinide chemistry are considered in this work. The accuracy of CCD0+DFT for predicting equilibrium geometries and vibrational frequencies of actinide molecules and ions is assessed and compared to that of well-established quantum chemical methods. For this purpose, the f0 actinyl series (UO2 2+, NpO 23+, PuO24+, the isoelectronic NUN, and Thorium (ThO, ThO2+) and Nobelium (NoO, NoO2) oxides are studied. It is shown that the CCD0+DFT description of these species agrees with available experimental data and is comparable with the results given by the highest-level calculations that are possible for such heavy compounds while being, at least, an order of magnitude lower in computational cost.
The prevalence and geographic distribution of complex co-occurring disorders: a population study.
Somers, J M; Moniruzzaman, A; Rezansoff, S N; Brink, J; Russolillo, A
2016-06-01
A subset of people with co-occurring substance use and mental disorders require coordinated support from health, social welfare and justice agencies to achieve diversion from homelessness, criminal recidivism and further health and social harms. Integrated models of care are typically concentrated in large urban centres. The present study aimed to empirically measure the prevalence and distribution of complex co-occurring disorders (CCD) in a large geographic region that includes urban as well as rural and remote settings. Linked data were examined in a population of roughly 3.7 million adults. Inclusion criteria for the CCD subpopulation were: physician diagnosed substance use and mental disorders; psychiatric hospitalisation; shelter assistance; and criminal convictions. Prevalence per 100 000 was calculated in 91 small areas representing urban, rural and remote settings. 2202 individuals met our inclusion criteria for CCD. Participants had high rates of hospitalisation (8.2 admissions), criminal convictions (8.6 sentences) and social assistance payments (over $36 000 CDN) in the past 5 years. There was wide variability in the geographic distribution of people with CCD, with high prevalence rates in rural and remote settings. People with CCD are not restricted to areas with large populations or to urban settings. The highest per capita rates of CCD were observed in relatively remote locations, where mental health and substance use services are typically in limited supply. Empirically supported interventions must be adapted to meet the needs of people living outside of urban settings with high rates of CCD.
Soriano-Arandes, Antoni; Angheben, Andrea; Serre-Delcor, Nuria; Treviño-Maruri, Begoña; Gómez I Prat, Jordi; Jackson, Yves
2016-05-01
Identifying pregnant women infected with Trypanosoma cruzi is one of the major challenges for preventing and controlling Chagas disease (CD) in non-endemic countries. The aim of this paper was to perform a policy evaluation of the current practices of congenital Chagas disease (CCD) control in non-endemic countries and to propose specific targets for enhanced interventions to tackle this emerging health problem outside the endemic areas of Latin America. We conducted a mixed method review of CCD policy strategies by searching the literature in the PubMed, Google Scholar and the World Health Organization (WHO) databases using the key terms 'CCD', 'paediatric Chagas disease' and 'non-endemic countries'; as free text and combined as one phrase to increase the search sensitivity. Reviews, recommendations, guidelines and control/surveillance programme reports were included. Of 427 CCD papers identified in non-endemic countries, 44 matched the inclusion. Although local programmes were launched in different countries with large numbers of Latin American immigrants, there were considerable disparities in terms of the programmes' distribution, delivery, integration and appropriated CCD control strategies. Moreover, Catalonia, Spain is the only region/country with an established systematic monitoring of CCD in pregnant women from Latin American countries. Given the worldwide dissemination of CD, the nature of its vertical transmission, and the gaps of the current strategies in non-endemic countries, there is an urgent need to standardise, expand and reinforce the control measures against CCD transmission. © 2016 John Wiley & Sons Ltd.
Development and use of an L3CCD high-cadence imaging system for Optical Astronomy
NASA Astrophysics Data System (ADS)
Sheehan, Brendan J.; Butler, Raymond F.
2008-02-01
A high cadence imaging system, based on a Low Light Level CCD (L3CCD) camera, has been developed for photometric and polarimetric applications. The camera system is an iXon DV-887 from Andor Technology, which uses a CCD97 L3CCD detector from E2V technologies. This is a back illuminated device, giving it an extended blue response, and has an active area of 512×512 pixels. The camera system allows frame-rates ranging from 30 fps (full frame) to 425 fps (windowed & binned frame). We outline the system design, concentrating on the calibration and control of the L3CCD camera. The L3CCD detector can be either triggered directly by a GPS timeserver/frequency generator or be internally triggered. A central PC remotely controls the camera computer system and timeserver. The data is saved as standard `FITS' files. The large data loads associated with high frame rates, leads to issues with gathering and storing the data effectively. To overcome such problems, a specific data management approach is used, and a Python/PYRAF data reduction pipeline was written for the Linux environment. This uses calibration data collected either on-site, or from lab based measurements, and enables a fast and reliable method for reducing images. To date, the system has been used twice on the 1.5 m Cassini Telescope in Loiano (Italy) we present the reduction methods and observations made.
Janossy, G; Coustan-Smith, E; Campana, D
1989-03-01
Current views about the origin of acute lymphoid leukemia (ALL) emphasize the importance of maturation arrest at a precursor cell level. Recently, the CD22 antigen has been identified in the cytoplasm of normal bone marrow-borne immature B lineage cells, while the CD3 antigen (epsilon chain) has been detected within normal immature thymic blasts. In the first part our study performed on 100 cases of known acute leukemias, the expression of such cytoplasmic molecules, referred to as cCD22 and cCD3, was analyzed together with their appearance in the leukemic cells' membrane (mCD22 and mCD3). The presence of cCD22 in B-lineage ALL and that of cCD3 in T-ALL has indeed fully confirmed the diagnosis reached by other markers, and mCD22 and mCD3 were expressed on only a few cases of B- and T-lineage ALL, also revealing a degree of developmental asynchrony within leukemic blasts. In the subsequent analysis both cCD22 and cCD3 have been included in a standard panel of diagnostic reagents applied on 500 consecutive cases of acute leukemia. Here the aim was to analyze both the diagnostic precision of individual markers and the heterogeneity of various leukemic types in terms of the expression of membrane and intracellular antigens and their cytochemical features (Sudan Black B and esterases). It has been found that cCD22 and cCD3 are exquisitely specific for B-precursor ALL (TdT+, CD19+) and T-ALL (TdT+, CD7+), respectively, while both markers are absent in acute myeloblastic leukemia (AML) and acute myelomonocytic and monocytic leukemia (AMML/AMoL). These observations contrast the findings which demonstrate that 31% of cases among nonlymphoid acute leukemia (including AML and AMML) express CD7 and/or TdT. The study of myeloid antigens detected by CD13, CD33, and CD14 is also informative and complementary, both in diagnosing and subdividing the AML and AMML/AMoL groups. The peculiar main observation of this study is that only with the combined use of these markers in a microplate assay for membrane antigens, followed by double staining for intracellular antigens such as terminal deoxynucleotidyl transferase, cCD3, cCD22, c mu heavy chain, and T cell receptor beta, it is possible to safely establish the lineage affiliation and subgrouping of virtually all acute leukemias. Among these cases are those with aberrant combinations of markers, including 14% of B-lineage ALL (cCD22+,CD19+,TdT+) and a single case T-ALL (cCD3+,CD7+,TdT+), which exhibit CD13 and/or CD33 antigens, cases with mixtures of ALL and AML blasts, and 1.2% of acute leukemias which lack lineage affiliation and can be regarded as acute undifferentiated leukemia.
NASA Astrophysics Data System (ADS)
Chávez-Estrada, Marisol; Aguilar-Arevalo, Alexis A.
2017-10-01
We study the potential of a detector based on CCD sensors (CONNIE experiment) to study neutrino oscillations to sterile states using reactor neutrinos. We calculate the number of events expected in a 1 kg detector and determine the sensitivity to oscillations νe → νs in the Δ m412 vs. sin2 θes parameter space for various exposures. The sensitivity is compared with the regions excluded by the Daya Bay experiment under the assumption θ 24 = θ 34 = 0. This work was carried out independently of the CONNIE Collaboration using published information, and its results are not official.
NASA Astrophysics Data System (ADS)
Liakos, A.; Niarchos, P.
2009-03-01
CCD observations of 24 eclipsing binary systems with spectral types ranging between A0-F0, candidate for containing pulsating components, were obtained. Appropriate exposure times in one or more photometric filters were used so that short-periodic pulsations could be detected. Their light curves were analyzed using the Period04 software in order to search for pulsational behaviour. Two new variable stars, namely GSC 2673-1583 and GSC 3641-0359, were discov- ered as by-product during the observations of eclipsing variables. The Fourier analysis of the observations of each star, the dominant pulsation frequencies and the derived frequency spectra are also presented.
Optical observations of Swift J1822.3-1606 with the 10.4m Gran Telescopio Canarias
NASA Astrophysics Data System (ADS)
Rea, N.; Mignani, R. P.; Israel, G. L.; Esposi, P.
2011-07-01
We observed the field of the new Soft Gamma-ray Repeater (SGR), Swift J1822.3-1606 (Cummings et al., Atel #3488) with the 10.4m Gran Telescopio Canarias (GranTeCan). Images have been taken with the OSIRIS camera, a two-chip CCD with a nominal 7.8'x7.8' arcmin field of view and a pixel size of 0.125". Observations have been taken in the z-Sloan-band on 2011 July 21st (unfortunately in bright lunar time, with a large sky background and a seeing ranging from 1-2.5") with exposure times of 54-108s.
Canning, John; Lau, Angelica; Naqshbandi, Masood; Petermann, Ingemar; Crossley, Maxwell J
2011-01-01
The blue OLED emission from a mobile phone was characterised, revealing a sharp emission band centred at λ = 445 nm with a 3dB bandwidth Δλ ∼ 20 nm. It was used to excite Rhodamine 123 doped within a "giant" mesostructured silica sphere during fabrication through evaporative self-assembly of silica nanoparticles. Fluorescence was able to be detected using a standard optical microscope fitted with a green transmission pass filter and cooled CCD and with 1 ms exposure time demonstrating the potential of mobile platforms as the basis for portable diagnostics in the field.
Dynamical investigations of the multiple stars
NASA Astrophysics Data System (ADS)
Kiyaeva, Olga V.; Zhuchkov, Roman Ya.
2017-11-01
Two multiple stars - the quadruple star - Bootis (ADS 9173) and the triple star T Taury were investigated. The visual double star - Bootiswas studied on the basis of the Pulkovo 26-inch refractor observations 1982-2013. An invisible satellite of the component A was discovered due to long-term uniform series of observations. Its orbital period is 20 ± 2 years. The known invisible satellite of the component B with near 5 years period was confirmed due to high precision CCD observations. The astrometric orbits of the both components were calculated. The orbits of inner and outer pairs of the pre-main sequence binary T Taury were calculated on the basis of high precision observations by the VLT and on the Keck II Telescope. This weakly hierarchical triple system is stable with probability more than 70%.
Multiple-Point Mass Flux Measurement System Using Rayleigh Scattering
NASA Technical Reports Server (NTRS)
Mielke, Amy F.; Elam, Kristie A.; Clem, Michelle M.
2009-01-01
A multiple-point Rayleigh scattering diagnostic is being developed to provide mass flux measurements in gas flows. Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous density, temperature, and velocity measurements. Rayleigh scattered light from a focused 18 Watt continuous-wave laser beam is directly imaged through a solid Fabry-Perot etalon onto a CCD detector which permits spectral analysis of the light. The spatial resolution of the measurements is governed by the locations of interference fringes, which can be changed by altering the etalon characteristics. A prototype system has been used to acquire data in a Mach 0.56 flow to demonstrate feasibility of using this system to provide mass flux measurements. Estimates of measurement uncertainty and recommendations for system improvements are presented
Test of CCD Precision Limits for Differential Photometry
NASA Technical Reports Server (NTRS)
Robinson, L. B.; Wei, M. Z.; Borucki, W. J.; Dunham, E. W.; Ford, C. H.; Granados, A. F.
1995-01-01
Results of tests to demonstrate the very high differential-photometric stability of CCD light sensors are presented. The measurements reported here demonstrate that in a controlled laboratory environment, a front-illuminated CCD can provide differential-photometric measurements with reproducible precision approaching one part in 10(exp 5). Practical limitations to the precision of differential-photometric measurements with CCDs and implications for spaceborne applications are discussed.
NASA Astrophysics Data System (ADS)
Park, Sun-Youp; Choi, Jin; Roh, Dong-Goo; Park, Maru; Jo, Jung Hyun; Yim, Hong-Suh; Park, Young-Sik; Bae, Young-Ho; Park, Jang-Hyun; Moon, Hong-Kyu; Choi, Young-Jun; Cho, Sungki; Choi, Eun-Jung
2016-09-01
As described in the previous paper (Park et al. 2013), the detector subsystem of optical wide-field patrol (OWL) provides many observational data points of a single artificial satellite or space debris in the form of small streaks, using a chopper system and a time tagger. The position and the corresponding time data are matched assuming that the length of a streak on the CCD frame is proportional to the time duration of the exposure during which the chopper blades do not obscure the CCD window. In the previous study, however, the length was measured using the diagonal of the rectangle of the image area containing the streak; the results were quite ambiguous and inaccurate, allowing possible matching error of positions and time data. Furthermore, because only one (position, time) data point is created from one streak, the efficiency of the observation decreases. To define the length of a streak correctly, it is important to locate the endpoints of a streak. In this paper, a method using a differential convolution mask pattern is tested. This method can be used to obtain the positions where the pixel values are changed sharply. These endpoints can be regarded as directly detected positional data, and the number of data points is doubled by this result.
Insect Wing Displacement Measurement Using Digital Holography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aguayo, Daniel D.; Mendoza Santoyo, Fernando; Torre I, Manuel H. de la
2008-04-15
Insects in flight have been studied with optical non destructive techniques with the purpose of using meaningful results in aerodynamics. With the availability of high resolution and large dynamic range CCD sensors the so called interferometric digital holographic technique was used to measure the surface displacement of in flight insect wings, such as butterflies. The wings were illuminated with a continuous wave Verdi laser at 532 nm, and observed with a CCD Pixelfly camera that acquire images at a rate of 11.5 frames per second at a resolution of 1392x1024 pixels and 12 Bit dynamic range. At this frame ratemore » digital holograms of the wings were captured and processed in the usual manner, namely, each individual hologram is Fourier processed in order to find the amplitude and phase corresponding to the digital hologram. The wings displacement is obtained when subtraction between two digital holograms is performed for two different wings position, a feature applied to all consecutive frames recorded. The result of subtracting is seen as a wrapped phase fringe pattern directly related to the wing displacement. The experimental data for different butterfly flying conditions and exposure times are shown as wire mesh plots in a movie of the wings displacement.« less
Measuring the effective pixel positions for the HARPS3 CCD
NASA Astrophysics Data System (ADS)
Hall, Richard D.; Thompson, Samantha; Queloz, Didier
2016-07-01
We present preliminary results from an experiment designed to measure the effective pixel positions of a CCD to sub-pixel precision. This technique will be used to characterise the 4k x 4k CCD destined for the HARPS-3 spectrograph. The principle of coherent beam interference is used to create intensity fringes along one axis of the CCD. By sweeping the physical parameters of the experiment, the geometry of the fringes can be altered which is used to probe the pixel structure. We also present the limitations of the current experimental set-up and suggest what will be implemented in the future to vastly improve the precision of the measurements.
Vacuum compatible miniature CCD camera head
Conder, Alan D.
2000-01-01
A charge-coupled device (CCD) camera head which can replace film for digital imaging of visible light, ultraviolet radiation, and soft to penetrating x-rays, such as within a target chamber where laser produced plasmas are studied. The camera head is small, capable of operating both in and out of a vacuum environment, and is versatile. The CCD camera head uses PC boards with an internal heat sink connected to the chassis for heat dissipation, which allows for close(0.04" for example) stacking of the PC boards. Integration of this CCD camera head into existing instrumentation provides a substantial enhancement of diagnostic capabilities for studying high energy density plasmas, for a variety of military industrial, and medical imaging applications.
NASA Astrophysics Data System (ADS)
Harshaw, Richard
2018-04-01
In the winter and spring of 2017, an aggressive observing program of measuring close double stars with speckle interferometry and CCD imaging was undertaken at Brilliant Sky Observatory, my observing site in Cave Creek, Arizona. A total of 596 stars were observed, 8 of which were rejected for various reasons, leaving 588 pairs. Of these, 427 were observed and measured with speckle interferometry, while the remaining 161 were measured with a CCD. This paper reports the results of the observations of the 161 CCD cases. A separate paper in this issue will report the speckle measurements of the 427 other pairs.
A survey of nebulae around galactic wolf-rayet stars in the southern sky, 2.
NASA Technical Reports Server (NTRS)
Marston, A. P.; Yocum, D. R.; Garcia-Segura, G.; Chu, Y.-H.
1994-01-01
We present the second half of a charge coupled device (CCD) narrow-band imaging survey of galactic Wolf-Rayet stars located in the southern hemisphere as listed by van der Hucht et al. (1981). Images of 50 Wolf-Rayet stars were taken using a wide-field CCD and narrowband interference filters centered on H alpha and (O III) 5007 A wavelengths. The first half of the survey (Marston, Chu, & Garcia-Segura 1993, hereafter Paper I) revealed six new ring nebulae residing around Wolf-Rayet stars. Here we reveal a possible 11 new rings and the existence of multiple rings associated with two previously known nebula, RCW 118 and G2.4+1.4 and around the stars WR 16 and WR 43. Combining our results with those of Miller & Chu (1993) and Paper I, 92% of the van der Hucht catalog of Wolf-Rayet stars have now been surveyed. Of the 38 possible ring nebulae found in our surveys to date, 22 reside around WN subtype Wolf-Rayet stars, 13 around WC stars, one around a triplet of Wolf-Rayet stars and one around a WO star (WR 102). One ring exists around a WN/WC star (WR 98). A bias toward rings being observed around W-R + OB binaries is noted. Such pairings are generally bright, and the detection of a ring around them may merely be a function of their combined luminosity. Several Wolf-Rayet stars are shown to be surrounded by multiple rings (two or three) which suggests that a number of ejections of stellar material have taken place during their evolution.
A survey of nebulae around galactic wolf-rayet stars in the southern sky, 2.
NASA Astrophysics Data System (ADS)
Marston, A. P.; Yocum, D. R.; Garcia-Segura, G.; Chu, Y.-H.
1994-11-01
We present the second half of a charge coupled device (CCD) narrow-band imaging survey of galactic Wolf-Rayet stars located in the southern hemisphere as listed by van der Hucht et al. (1981). Images of 50 Wolf-Rayet stars were taken using a wide-field CCD and narrowband interference filters centered on H alpha and (O III) 5007 A wavelengths. The first half of the survey (Marston, Chu, & Garcia-Segura 1993, hereafter Paper I) revealed six new ring nebulae residing around Wolf-Rayet stars. Here we reveal a possible 11 new rings and the existence of multiple rings associated with two previously known nebula, RCW 118 and G2.4+1.4 and around the stars WR 16 and WR 43. Combining our results with those of Miller & Chu (1993) and Paper I, 92% of the van der Hucht catalog of Wolf-Rayet stars have now been surveyed. Of the 38 possible ring nebulae found in our surveys to date, 22 reside around WN subtype Wolf-Rayet stars, 13 around WC stars, one around a triplet of Wolf-Rayet stars and one around a WO star (WR 102). One ring exists around a WN/WC star (WR 98). A bias toward rings being observed around W-R + OB binaries is noted. Such pairings are generally bright, and the detection of a ring around them may merely be a function of their combined luminosity. Several Wolf-Rayet stars are shown to be surrounded by multiple rings (two or three) which suggests that a number of ejections of stellar material have taken place during their evolution.
Characterization of viral siRNA populations in honey bee colony collapse disorder.
Chejanovsky, Nor; Ophir, Ron; Schwager, Michal Sharabi; Slabezki, Yossi; Grossman, Smadar; Cox-Foster, Diana
2014-04-01
Colony Collapse Disorder (CCD), a special case of collapse of honey bee colonies, has resulted in significant losses for beekeepers. CCD-colonies show abundance of pathogens which suggests that they have a weakened immune system. Since honey bee viruses are major players in colony collapse and given the important role of viral RNA interference (RNAi) in combating viral infections we investigated if CCD-colonies elicit an RNAi response. Deep-sequencing analysis of samples from CCD-colonies from US and Israel revealed abundant small interfering RNAs (siRNA) of 21-22 nucleotides perfectly matching the Israeli acute paralysis virus (IAPV), Kashmir virus and Deformed wing virus genomes. Israeli colonies showed high titers of IAPV and a conserved RNAi-pattern of matching the viral genome. That was also observed in sample analysis from colonies experimentally infected with IAPV. Our results suggest that CCD-colonies set out a siRNA response that is specific against predominant viruses associated with colony losses. Copyright © 2014 Elsevier Inc. All rights reserved.
Dolin, Robert H.; Giannone, Gay; Schadow, Gunther
2007-01-01
We sought to determine how well the HL7 / ASTM Continuity of Care Document (CCD) standard supports the requirements underlying the Joint Commission medication reconciliation recommendations. In particular, the Joint Commission emphasizes that transition points in the continuum of care are vulnerable to communication breakdowns, and that these breakdowns are a common source of medication errors. These transition points are the focus of communication standards, suggesting that CCD can support and enable medication related patient safety initiatives. Data elements needed to support the Joint Commission recommendations were identified and mapped to CCD, and a detailed clinical scenario was constructed. The mapping identified minor gaps, and identified fields present in CCD not specifically identified by Joint Commission, but useful nonetheless when managing medications across transitions of care, suggesting that a closer collaboration between the Joint Commission and standards organizations will be mutually beneficial. The nationally recognized CCD specification provides a standards-based solution for enabling Joint Commission medication reconciliation objectives. PMID:18693823
Dolin, Robert H; Giannone, Gay; Schadow, Gunther
2007-10-11
We sought to determine how well the HL7/ASTM Continuity of Care Document (CCD) standard supports the requirements underlying the Joint Commission medication reconciliation recommendations. In particular, the Joint Commission emphasizes that transition points in the continuum of care are vulnerable to communication breakdowns, and that these breakdowns are a common source of medication errors. These transition points are the focus of communication standards, suggesting that CCD can support and enable medication related patient safety initiatives. Data elements needed to support the Joint Commission recommendations were identified and mapped to CCD, and a detailed clinical scenario was constructed. The mapping identified minor gaps, and identified fields present in CCD not specifically identified by Joint Commission, but useful nonetheless when managing medications across transitions of care, suggesting that a closer collaboration between the Joint Commission and standards organizations will be mutually beneficial. The nationally recognized CCD specification provides a standards-based solution for enabling Joint Commission medication reconciliation objectives.
The Speckle Toolbox: A Powerful Data Reduction Tool for CCD Astrometry
NASA Astrophysics Data System (ADS)
Harshaw, Richard; Rowe, David; Genet, Russell
2017-01-01
Recent advances in high-speed low-noise CCD and CMOS cameras, coupled with breakthroughs in data reduction software that runs on desktop PCs, has opened the domain of speckle interferometry and high-accuracy CCD measurements of double stars to amateurs, allowing them to do useful science of high quality. This paper describes how to use a speckle interferometry reduction program, the Speckle Tool Box (STB), to achieve this level of result. For over a year the author (Harshaw) has been using STB (and its predecessor, Plate Solve 3) to obtain measurements of double stars based on CCD camera technology for pairs that are either too wide (the stars not sharing the same isoplanatic patch, roughly 5 arc-seconds in diameter) or too faint to image in the coherence time required for speckle (usually under 40ms). This same approach - using speckle reduction software to measure CCD pairs with greater accuracy than possible with lucky imaging - has been used, it turns out, for several years by the U. S. Naval Observatory.
Single-Electron and Single-Photon Sensitivity with a Silicon Skipper CCD
Tiffenberg, Javier; Sofo-Haro, Miguel; Drlica-Wagner, Alex; ...
2017-09-26
Here, we have developed ultralow-noise electronics in combination with repetitive, nondestructive readout of a thick, fully depleted charge-coupled device (CCD) to achieve an unprecedented noise level of 0.068 e - rms/pixel. This is the first time that discrete subelectron readout noise has been achieved reproducible over millions of pixels on a stable, large-area detector. This enables the contemporaneous, discrete, and quantized measurement of charge in pixels, irrespective of whether they contain zero electrons or thousands of electrons. Thus, the resulting CCD detector is an ultra-sensitive calorimeter. It is also capable of counting single photons in the optical and near-infrared regime.more » Implementing this innovative non-destructive readout system has a negligible impact on CCD design and fabrication, and there are nearly immediate scientific applications. As a particle detector, this CCD will have unprecedented sensitivity to low-mass dark matter particles and coherent neutrino-nucleus scattering, while future astronomical applications may include direct imaging and spectroscopy of exoplanets.« less
Development of a Portable 3CCD Camera System for Multispectral Imaging of Biological Samples
Lee, Hoyoung; Park, Soo Hyun; Noh, Sang Ha; Lim, Jongguk; Kim, Moon S.
2014-01-01
Recent studies have suggested the need for imaging devices capable of multispectral imaging beyond the visible region, to allow for quality and safety evaluations of agricultural commodities. Conventional multispectral imaging devices lack flexibility in spectral waveband selectivity for such applications. In this paper, a recently developed portable 3CCD camera with significant improvements over existing imaging devices is presented. A beam-splitter prism assembly for 3CCD was designed to accommodate three interference filters that can be easily changed for application-specific multispectral waveband selection in the 400 to 1000 nm region. We also designed and integrated electronic components on printed circuit boards with firmware programming, enabling parallel processing, synchronization, and independent control of the three CCD sensors, to ensure the transfer of data without significant delay or data loss due to buffering. The system can stream 30 frames (3-waveband images in each frame) per second. The potential utility of the 3CCD camera system was demonstrated in the laboratory for detecting defect spots on apples. PMID:25350510
Odlum, Michelle; Gordon, Peter; Camhi, Eli; Schnall, Rebecca; Teixeira, Paul; Bakken, Suzanne
2012-11-01
The provision of personal health information through electronic personal health management tools (EPHMT) has the potential to improve health outcomes. However, little is known about factors that affect EPHMT use in special needs people living with HIV/AIDS (PLWH). The purpose of this study was to describe PLWH perceptions of predisposing, enabling, and reinforcing factors affecting use of one type of EPHMT, a continuity of care document (CCD). Data were collected through focus groups and qualitative interviews with PLWH (n=35), health care providers (N=19) and care site managers (N=5). All participant types identified predisposing barriers to CCD use including literacy, privacy, and technology access and enabling factors to promote CCD use including user support and password simplicity. People living with HIV/AIDS also identified reinforcing factors for recurring CCD use including emergent situations and reducing test redundancy. Results inform methods to promote use of the CCD and other EPHMT by special needs PLWH.
Concordia CCD - A Geoscope station in continental Antarctica
NASA Astrophysics Data System (ADS)
Maggi, A.; Lévêque, J.; Thoré, J.; Bes de Berc, M.; Bernard, A.; Danesi, S.; Morelli, A.; Delladio, A.; Sorrentino, D.; Stutzmann, E.; Geoscope Team
2010-12-01
Concordia (Dome C, Antarctica) has had a permanent seismic station since 2005. It is run by EOST and INGV in collaboration with the French and Italian polar institutes (IPEV and PNRA). It is installed in an ice-vault, at 12m depth, distant 1km from the permanent scientific base at Concordia. The temperature in the vault is a constant -55°C. The data quality at the station has improved continuously since its installation. In 2007, the station was declared at ISC as an open station with station code CCD (ConCorDia), with data available upon request. It is only the second permanent station in the Antarctic continent, after South Pole. In 2010, CCD was included in the Geoscope network. Data from CCD starting in 2007 are now freely available from the Geoscope Data Center and IRIS. We present an analysis of the data quality at CCD, and describe the technical difficulties of operating an observatory-quality seismic station in the extreme environmental conditons present in continental Antarctica.
Single-Electron and Single-Photon Sensitivity with a Silicon Skipper CCD
NASA Astrophysics Data System (ADS)
Tiffenberg, Javier; Sofo-Haro, Miguel; Drlica-Wagner, Alex; Essig, Rouven; Guardincerri, Yann; Holland, Steve; Volansky, Tomer; Yu, Tien-Tien
2017-09-01
We have developed ultralow-noise electronics in combination with repetitive, nondestructive readout of a thick, fully depleted charge-coupled device (CCD) to achieve an unprecedented noise level of 0.068 e- rms /pixel . This is the first time that discrete subelectron readout noise has been achieved reproducible over millions of pixels on a stable, large-area detector. This enables the contemporaneous, discrete, and quantized measurement of charge in pixels, irrespective of whether they contain zero electrons or thousands of electrons. Thus, the resulting CCD detector is an ultra-sensitive calorimeter. It is also capable of counting single photons in the optical and near-infrared regime. Implementing this innovative non-destructive readout system has a negligible impact on CCD design and fabrication, and there are nearly immediate scientific applications. As a particle detector, this CCD will have unprecedented sensitivity to low-mass dark matter particles and coherent neutrino-nucleus scattering, while future astronomical applications may include direct imaging and spectroscopy of exoplanets.
Single-Electron and Single-Photon Sensitivity with a Silicon Skipper CCD.
Tiffenberg, Javier; Sofo-Haro, Miguel; Drlica-Wagner, Alex; Essig, Rouven; Guardincerri, Yann; Holland, Steve; Volansky, Tomer; Yu, Tien-Tien
2017-09-29
We have developed ultralow-noise electronics in combination with repetitive, nondestructive readout of a thick, fully depleted charge-coupled device (CCD) to achieve an unprecedented noise level of 0.068 e^{-} rms/pixel. This is the first time that discrete subelectron readout noise has been achieved reproducible over millions of pixels on a stable, large-area detector. This enables the contemporaneous, discrete, and quantized measurement of charge in pixels, irrespective of whether they contain zero electrons or thousands of electrons. Thus, the resulting CCD detector is an ultra-sensitive calorimeter. It is also capable of counting single photons in the optical and near-infrared regime. Implementing this innovative non-destructive readout system has a negligible impact on CCD design and fabrication, and there are nearly immediate scientific applications. As a particle detector, this CCD will have unprecedented sensitivity to low-mass dark matter particles and coherent neutrino-nucleus scattering, while future astronomical applications may include direct imaging and spectroscopy of exoplanets.
VizieR Online Data Catalog: IC 361 Vilnius photometry (Zdanavicius+, 2010)
NASA Astrophysics Data System (ADS)
Zdanavicius, J.; Bartasiute, S.; Boyle, R. P.; Vrba, F. J.; Zdanavicius, K.
2015-03-01
CCD observations in seven filters U,P,X,Y,Z,V,S of the Vilnius system plus the filter I of the Cousins system were carried out in December of 1999 with a 2K CCD camera on the 1m telescope of the USNO Flagstaff Station (Arizona), which gives a field of the diameter of 20'. Repeated observations in the Vilnius filters were done with the same telescope and a new 2Kx2K CCD camera in March of 2009. During the latter run we have obtained well-calibrated CCD data only for filters Y, Z, V, S, since observations through the remaining three filters on the succeeding night were curtailed by cirrus clouds. Additional frames in the Vilnius filters U,Y,V were taken for the central part of the field (12'x12') in December of 2008 with a 4K CCD camera on the 1.8m Vatican Advanced Technology Telescope (VATT) on Mt. Graham (Arizona). (1 data file).
Ko, Yi-An; Mukherjee, Bhramar; Smith, Jennifer A; Kardia, Sharon L R; Allison, Matthew; Diez Roux, Ana V
2016-11-01
There has been an increased interest in identifying gene-environment interaction (G × E) in the context of multiple environmental exposures. Most G × E studies analyze one exposure at a time, but we are exposed to multiple exposures in reality. Efficient analysis strategies for complex G × E with multiple environmental factors in a single model are still lacking. Using the data from the Multiethnic Study of Atherosclerosis, we illustrate a two-step approach for modeling G × E with multiple environmental factors. First, we utilize common clustering and classification strategies (e.g., k-means, latent class analysis, classification and regression trees, Bayesian clustering using Dirichlet Process) to define subgroups corresponding to distinct environmental exposure profiles. Second, we illustrate the use of an additive main effects and multiplicative interaction model, instead of the conventional saturated interaction model using product terms of factors, to study G × E with the data-driven exposure subgroups defined in the first step. We demonstrate useful analytical approaches to translate multiple environmental exposures into one summary class. These tools not only allow researchers to consider several environmental exposures in G × E analysis but also provide some insight into how genes modify the effect of a comprehensive exposure profile instead of examining effect modification for each exposure in isolation.
Particle displacement tracking applied to air flows
NASA Technical Reports Server (NTRS)
Wernet, Mark P.
1991-01-01
Electronic Particle Image Velocimeter (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single cw laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640x480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.
Development of proton CT imaging system using plastic scintillator and CCD camera
NASA Astrophysics Data System (ADS)
Tanaka, Sodai; Nishio, Teiji; Matsushita, Keiichiro; Tsuneda, Masato; Kabuki, Shigeto; Uesaka, Mitsuru
2016-06-01
A proton computed tomography (pCT) imaging system was constructed for evaluation of the error of an x-ray CT (xCT)-to-WEL (water-equivalent length) conversion in treatment planning for proton therapy. In this system, the scintillation light integrated along the beam direction is obtained by photography using the CCD camera, which enables fast and easy data acquisition. The light intensity is converted to the range of the proton beam using a light-to-range conversion table made beforehand, and a pCT image is reconstructed. An experiment for demonstration of the pCT system was performed using a 70 MeV proton beam provided by the AVF930 cyclotron at the National Institute of Radiological Sciences. Three-dimensional pCT images were reconstructed from the experimental data. A thin structure of approximately 1 mm was clearly observed, with spatial resolution of pCT images at the same level as that of xCT images. The pCT images of various substances were reconstructed to evaluate the pixel value of pCT images. The image quality was investigated with regard to deterioration including multiple Coulomb scattering.
Colony collapse disorder in Europe.
Dainat, Benjamin; Vanengelsdorp, Dennis; Neumann, Peter
2012-02-01
Colony collapse disorder (CCD) is a condition of honey bees, which has contributed in part to the recent major losses of honey bee colonies in the USA. Here we report the first CCD case from outside of the USA. We suggest that more standardization is needed for the case definition to diagnose CCD and to compare data on a global scale. © 2011 Society for Applied Microbiology and Blackwell Publishing Ltd.
Performance of the STIS CCD Dark Rate Temperature Correction
NASA Astrophysics Data System (ADS)
Branton, Doug; STScI STIS Team
2018-06-01
Since July 2001, the Space Telescope Imaging Spectrograph (STIS) onboard Hubble has operated on its Side-2 electronics due to a failure in the primary Side-1 electronics. While nearly identical, Side-2 lacks a functioning temperature sensor for the CCD, introducing a variability in the CCD operating temperature. Previous analysis utilized the CCD housing temperature telemetry to characterize the relationship between the housing temperature and the dark rate. It was found that a first-order 7%/°C uniform dark correction demonstrated a considerable improvement in the quality of dark subtraction on Side-2 era CCD data, and that value has been used on all Side-2 CCD darks since. In this report, we show how this temperature correction has performed historically. We compare the current 7%/°C value against the ideal first-order correction at a given time (which can vary between ~6%/°C and ~10%/°C) as well as against a more complex second-order correction that applies a unique slope to each pixel as a function of dark rate and time. At worst, the current correction has performed ~1% worse than the second-order correction. Additionally, we present initial evidence suggesting that the variability in pixel temperature-sensitivity is significant enough to warrant a temperature correction that considers pixels individually rather than correcting them uniformly.
Typical effects of laser dazzling CCD camera
NASA Astrophysics Data System (ADS)
Zhang, Zhen; Zhang, Jianmin; Shao, Bibo; Cheng, Deyan; Ye, Xisheng; Feng, Guobin
2015-05-01
In this article, an overview of laser dazzling effect to buried channel CCD camera is given. The CCDs are sorted into staring and scanning types. The former includes the frame transfer and interline transfer types. The latter includes linear and time delay integration types. All CCDs must perform four primary tasks in generating an image, which are called charge generation, charge collection, charge transfer and charge measurement. In camera, the lenses are needed to input the optical signal to the CCD sensors, in which the techniques for erasing stray light are used. And the electron circuits are needed to process the output signal of CCD, in which many electronic techniques are used. The dazzling effects are the conjunct result of light distribution distortion and charge distribution distortion, which respectively derive from the lens and the sensor. Strictly speaking, in lens, the light distribution is not distorted. In general, the lens are so well designed and fabricated that its stray light can be neglected. But the laser is of much enough intensity to make its stray light obvious. In CCD image sensors, laser can induce a so large electrons generation. Charges transfer inefficiency and charges blooming will cause the distortion of the charge distribution. Commonly, the largest signal outputted from CCD sensor is restricted by capability of the collection well of CCD, and can't go beyond the dynamic range for the subsequent electron circuits maintaining normal work. So the signal is not distorted in the post-processing circuits. But some techniques in the circuit can make some dazzling effects present different phenomenon in final image.
Effects of biomechanical forces on signaling in the cortical collecting duct (CCD)
Carrisoza-Gaytan, Rolando; Liu, Yu; Flores, Daniel; Else, Cindy; Lee, Heon Goo; Rhodes, George; Sandoval, Ruben M.; Kleyman, Thomas R.; Lee, Francis Young-In; Molitoris, Bruce; Satlin, Lisa M.
2014-01-01
An increase in tubular fluid flow rate (TFF) stimulates Na reabsorption and K secretion in the cortical collecting duct (CCD) and subjects cells therein to biomechanical forces including fluid shear stress (FSS) and circumferential stretch (CS). Intracellular MAPK and extracellular autocrine/paracrine PGE2 signaling regulate cation transport in the CCD and, at least in other systems, are affected by biomechanical forces. We hypothesized that FSS and CS differentially affect MAPK signaling and PGE2 release to modulate cation transport in the CCD. To validate that CS is a physiological force in vivo, we applied the intravital microscopic approach to rodent kidneys in vivo to show that saline or furosemide injection led to a 46.5 ± 2.0 or 170 ± 32% increase, respectively, in distal tubular diameter. Next, murine CCD (mpkCCD) cells were grown on glass or silicone coated with collagen type IV and subjected to 0 or 0.4 dyne/cm2 of FSS or 10% CS, respectively, forces chosen based on prior biomechanical modeling of ex vivo microperfused CCDs. Cells exposed to FSS expressed an approximately twofold greater abundance of phospho(p)-ERK and p-p38 vs. static cells, while CS did not alter p-p38 and p-ERK expression compared with unstretched controls. FSS induced whereas CS reduced PGE2 release by ∼40%. In conclusion, FSS and CS differentially affect ERK and p38 activation and PGE2 release in a cell culture model of the CD. We speculate that TFF differentially regulates biomechanical signaling and, in turn, cation transport in the CCD. PMID:24872319
Kohrt, Brandon A; Rasmussen, Andrew; Kaiser, Bonnie N; Haroz, Emily E; Maharjan, Sujen M; Mutamba, Byamah B; de Jong, Joop TVM; Hinton, Devon E
2014-01-01
Background Burgeoning global mental health endeavors have renewed debates about cultural applicability of psychiatric categories. This study’s goal is to review strengths and limitations of literature comparing psychiatric categories with cultural concepts of distress (CCD) such as cultural syndromes, culture-bound syndromes, and idioms of distress. Methods The Systematic Assessment of Quality in Observational Research (SAQOR) was adapted based on cultural psychiatry principles to develop a Cultural Psychiatry Epidemiology version (SAQOR-CPE), which was used to rate quality of quantitative studies comparing CCD and psychiatric categories. A meta-analysis was performed for each psychiatric category. Results Forty-five studies met inclusion criteria, with 18 782 unique participants. Primary objectives of the studies included comparing CCD and psychiatric disorders (51%), assessing risk factors for CCD (18%) and instrument validation (16%). Only 27% of studies met SAQOR-CPE criteria for medium quality, with the remainder low or very low quality. Only 29% of studies employed representative samples, 53% used validated outcome measures, 44% included function assessments and 44% controlled for confounding. Meta-analyses for anxiety, depression, PTSD and somatization revealed high heterogeneity (I2 > 75%). Only general psychological distress had low heterogeneity (I2 = 8%) with a summary effect odds ratio of 5.39 (95% CI 4.71-6.17). Associations between CCD and psychiatric disorders were influenced by methodological issues, such as validation designs (β = 16.27, 95%CI 12.75-19.79) and use of CCD multi-item checklists (β = 6.10, 95%CI 1.89-10.31). Higher quality studies demonstrated weaker associations of CCD and psychiatric disorders. Conclusions Cultural concepts of distress are not inherently unamenable to epidemiological study. However, poor study quality impedes conceptual advancement and service application. With improved study design and reporting using guidelines such as the SAQOR-CPE, CCD research can enhance detection of mental health problems, reduce cultural biases in diagnostic criteria and increase cultural salience of intervention trial outcomes. PMID:24366490
NASA Astrophysics Data System (ADS)
Prabhu, Vijendra; Rao, Bola Sadashiva S.; Mahato, Krishna Kishore
2014-02-01
Investigations on the use of Low Level Laser Therapy (LLLT) for wound healing especially with the red laser light have demonstrated its pro-healing potential on a variety of pre-clinical and surgical wounds. However, until now, in LLLT the effect of multiple exposure of low dose laser irradiation on acute wound healing on well-designed pre-clinical model is not much explored. The present study aimed to investigate the effect of multiple exposure of low dose Helium Neon laser on healing progression of full thickness excision wounds in Swiss albino mice. Further, the efficacy of the multiple exposure of low dose laser irradiation was compared with the single exposure of optimum dose. Full thickness excision wounds (circular) of 15 mm diameter were created, and subsequently illuminated with the multiple exposures (1, 2, 3, 4 and 5 exposure/ week until healing) of He-Ne (632.8 nm, 4.02 mWcm-2) laser at 0.5 Jcm-2 along with single exposure of optimum laser dose (2 J/cm-2) and un-illuminated controls. Classical biophysical parameters such as contraction kinetics, area under the curve and the mean healing time were documented as the assessment parameters to examine the efficacy of multiple exposures with low level laser dose. Experimental findings substantiated that either single or multiple exposures of 0.5 J/cm2 failed to produce any detectable alterations on wound contraction, area under the curve and mean healing time compared to single exposure of optimum dose (2 Jcm-2) and un-illuminated controls. Single exposure of optimum, laser dose was found to be ideal for acute wound healing.
Mitosek-Szewczyk, Krystyna; Tabarkiewicz, Jacek; Wilczynska, Barbara; Lobejko, Katarzyna; Berbecki, Jerzy; Nastaj, Marcin; Dworzanska, Ewa; Kolodziejczyk, Beata; Stelmasiak, Zbigniew; Rolinski, Jacek
2013-09-15
Cladribine causes sustained reduction in peripheral T and B cell populations while sparing other immune cells. We determined two populations of dendritic cells (DCs): namely CD1c(+)/CD19(-) (myeloid DCs) and CD303(+)/CD123(+) (plasmacytoid DCs), CD19(+) B lymphocytes, CD3(+) T lymphocytes and CD4(+) or CD8(+) subpopulations in patients with multiple sclerosis after cladribine therapy. We examined 50 patients with secondary progressive multiple sclerosis (SP MS) according to McDonalds et al.'s criteria, 2001 [15]. Blood samples were collected before the initiation of cladribine therapy and after 1st, 2nd, 3th, 4th and 5th courses of treatment. DC subsets, T and B cells were analyzed by flow cytometry. During cladribine treatment the myeloid DCs CD1c(+)/CD19(-) did not change (p=0.73175), and the plasmacytoid DCs CD303(+)/CD123(+) significantly increased (p=0.00034) which resulted in significant changes in the ratio of myeloid DCs to plasmacytoid DCs (p=0.00273). During therapy, B lymphocyte CD19(+) significantly decreased (p=0.00005) and significant changes in CD4(+) cells (p=0.00191), changes in CD8(+) cells (p=0.05760) and significant changes in CD3(+) (p=0.01822) were found. We noticed significant trend to increase the CD303(+) circulating the dendritic cells. This population produces large amounts of IFN-alfa. We found significant and rapid decrease in B cells and CD4(+) Th cells. Our results suggest two possible ways of beneficial cladribine influence on immune system in MS. Induction of IFN-alfa producing cells and their predominance over BDCA-1(+) DCs, which are associated with cytotoxic response. Additionally, cladribine could influence two populations of lymphocytes: B cells and Th lymphocytes responsible for induction of immune response against myelin antigens. Copyright © 2013 Elsevier B.V. All rights reserved.
Development of a CCD array as an imaging detector for advanced X-ray astrophysics facilities
NASA Technical Reports Server (NTRS)
Schwartz, D. A.
1981-01-01
The development of a charge coupled device (CCD) X-ray imager for a large aperture, high angular resolution X-ray telescope is discussed. Existing CCDs were surveyed and three candidate concepts were identified. An electronic camera control and computer interface, including software to drive a Fairchild 211 CCD, is described. In addition a vacuum mounting and cooling system is discussed. Performance data for the various components are given.
CCD Astrometry with Robotic Telescopes
NASA Astrophysics Data System (ADS)
AlZaben, Faisal; Li, Dewei; Li, Yongyao; Dennis, Aren Fene, Michael; Boyce, Grady; Boyce, Pat
2016-01-01
CCD images were acquired of three binary star systems: WDS06145+1148, WDS06206+1803, and WDS06224+2640. The astrometric solution, position angle, and separation of each system were calculated with MaximDL v6 and Mira Pro x64 software suites. The results were consistent with historical measurements in the Washington Double Star Catalog. Our analysis found some differences in measurements between single-shot color CCD cameras and traditional monochrome CCDs using a filter wheel.
A FORTRAN version implementation of block adjustment of CCD frames and its preliminary application
NASA Astrophysics Data System (ADS)
Yu, Y.; Tang, Z.-H.; Li, J.-L.; Zhao, M.
2005-09-01
A FORTRAN version implementation of the block adjustment (BA) of overlapping CCD frames is developed and its flowchart is shown. The program is preliminarily applied to obtain the optical positions of four extragalactic radio sources. The results show that because of the increase in the number and sky coverage of reference stars the precision of optical positions with BA is improved compared with the single CCD frame adjustment.
Applications of charge-coupled device transversal filters to communication
NASA Technical Reports Server (NTRS)
Buss, D. D.; Bailey, W. H.; Brodersen, R. W.; Hewes, C. R.; Tasch, A. F., Jr.
1975-01-01
The paper discusses the computational power of state-of-the-art charged-coupled device (CCD) transversal filters in communications applications. Some of the performance limitations of CCD transversal filters are discussed, with attention given to time delay and bandwidth, imperfect charge transfer efficiency, weighting coefficient error, noise, and linearity. The application of CCD transversal filters to matched filtering, spectral filtering, and Fourier analysis is examined. Techniques for making programmable transversal filters are briefly outlined.
CCD imaging system for the EUV solar telescope
NASA Astrophysics Data System (ADS)
Gong, Yan; Song, Qian; Ye, Bing-Xun
2006-01-01
In order to develop the detector adapted to the space solar telescope, we have built a CCD camera system capable of working in the extra ultraviolet (EUV) band, which is composed of one phosphor screen, one intensified system using a photocathode/micro-channel plate(MCP)/ phosphor, one optical taper and one chip of front-illuminated (FI) CCD without screen windows. All of them were stuck one by one with optical glue. The working principle of the camera system is presented; moreover we have employed the mesh experiment to calibrate and test the CCD camera system in 15~24nm, the position resolution of about 19 μm is obtained at the wavelength of 17.1nm and 19.5nm.
CCD centroiding analysis for Nano-JASMINE observation data
NASA Astrophysics Data System (ADS)
Niwa, Yoshito; Yano, Taihei; Araki, Hiroshi; Gouda, Naoteru; Kobayashi, Yukiyasu; Yamada, Yoshiyuki; Tazawa, Seiichi; Hanada, Hideo
2010-07-01
Nano-JASMINE is a very small satellite mission for global space astrometry with milli-arcsecond accuracy, which will be launched in 2011. In this mission, centroids of stars in CCD image frames are estimated with sub-pixel accuracy. In order to realize such a high precision centroiding an algorithm utilizing a least square method is employed. One of the advantages is that centroids can be calculated without explicit assumption of the point spread functions of stars. CCD centroiding experiment has been performed to investigate whether this data analysis is available, and centroids of artificial star images on a CCD are determined with a precision of less than 0.001 pixel. This result indicates parallaxes of stars within 300 pc from Sun can be observed in Nano-JASMINE.
Printed circuit board for a CCD camera head
Conder, Alan D.
2002-01-01
A charge-coupled device (CCD) camera head which can replace film for digital imaging of visible light, ultraviolet radiation, and soft to penetrating x-rays, such as within a target chamber where laser produced plasmas are studied. The camera head is small, capable of operating both in and out of a vacuum environment, and is versatile. The CCD camera head uses PC boards with an internal heat sink connected to the chassis for heat dissipation, which allows for close (0.04" for example) stacking of the PC boards. Integration of this CCD camera head into existing instrumentation provides a substantial enhancement of diagnostic capabilities for studying high energy density plasmas, for a variety of military industrial, and medical imaging applications.
CCD BVI c observations of Cepheids
NASA Astrophysics Data System (ADS)
Berdnikov, L. N.; Kniazev, A. Yu.; Sefako, R.; Kravtsov, V. V.; Zhujko, S. V.
2014-02-01
In 2008-2013, we obtained 11333 CCD BVI c frames for 57 Cepheids from the General Catalogue of Variable Stars. We performed our observations with the 76-cm telescope of the South African Astronomical Observatory (SAAO, South Africa) and the 40-cm telescope of the Cerro Armazones Astronomical Observatory of the Universidad Católica del Norte (OCA, Chile) using the SBIG ST-10XME CCD camera. The tables of observations, the plots of light curves, and the current light elements are presented. Comparison of our light curves with those constructed from photoelectric observations shows that the differences between their mean magnitudes exceed 0ṃ05 in 20% of the cases. This suggests the necessity of performing CCD observations for all Cepheids.
New Research by CCD Scanning for Comets and Asteroids
NASA Technical Reports Server (NTRS)
Gehrels, Tom
1997-01-01
Spacewatch was begun in 1980; its purpose is to explore the various populations of small objects within the solar system. Spacewatch provides data for studies of comets and asteroids, finds potential targets for space missions, and provides information on the environmental problem of possible impacts. Moving objects are discovered by scanning the sky with charge-coupled devices (CCDS) on the 0.9-meter Spacewatch Telescope of the University of Arizona on Kitt Peak. Each Spacewatch scan consists of three drift scan passes over an area of sky using a CCD filtered to a bandpass of 0.5-1.0 pm (approximately V+R+I with peak sensitivity at 0.7 pm). The effective exposure time for each pass is 143 seconds multiplied by the secant of the declination. The area covered by each scan is 32 arcminutes in declination by about 28 minutes of time in right ascension. The image scale is 1.05 arcseconds per pixel. Three passes take about 1.5 hours to complete and show motions of individual objects over a one hour time baseline. The limiting magnitude is about 21.5 in single scans. CCD scanning was developed by Spacewatch in the early 1980s, with improvements still being made - particularly by bringing a new 1.8-m Spacewatch Telescope on line. In the meantime, we have been finding some 30,000 new asteroids per year and applying their statistics to the study of the collisional history of the solar system. Spacewatch had found a total of 150 Near-Earth Asteroids (NEAS) and 8 new comets, and had recovered one lost comet (P/Spitaler in 1993). Spacewatch is also efficient in recovery of known comets and has detected and reported positions for more than 137,000 asteroids, mostly new ones in the main belt, including more than 10,882 asteroids designated by the Minor Planet Center (MPC).
Yang, Minghui; Sun, Steven; Kostov, Yordan; Rasooly, Avraham
2010-04-21
We describe a new eight channel Lab-On-a-Chip (LOC) for a Carbon Nanotube (CNT) based immunoassay with optical detection of Staphylococcal Enterotoxin B (SEB) for food safety applications. In this work, we combined four biosensing elements: (1) CNT technology for primary antibody immobilization, (2) Enhanced Chemiluminescence (ECL) for light signal generation, (3) a cooled charge-coupled device (CCD) for detection and (4) polymer lamination technology for developing a point of care immunological assay for SEB detection. Our concept for developing versatile LOCs, which can be used for many different applications, is to use a modular design with interchangeable recognition elements (e.g. various antibodies) to determine the specificity. Polymer lamination technology was used for the fabrication of a six layer, syringe operated LOC capable of analyzing eight samples simultaneously. An anti-SEB antibody-nanotube mixture was immobilized onto a polycarbonate strip, to serve as an interchangeable ligand surface that was then bonded onto the LOC. SEB samples are loaded into the device and detected by an ELISA assay using Horse Radish Peroxidase (HRP) conjugated anti-SEB IgG as a secondary antibody and ECL, with detection by a previously described portable cooled CCD detector. Eight samples of SEB in buffer or soy milk were assayed simultaneously with a limit of detection of 0.1 ng mL(-1). CNT immobilization of the antibody increased the sensitivity of detection six fold. Use of a simple interchangeable immunological surface allows this LOC to be adapted to any immunoassay by simply replacing the ligand surface. A syringe was used to move fluids for this assay so no power is needed to operate the device. Our versatile portable point-of-care CCD detector combined with the LOC immunoassay method described here can be used to reduce the exposure of users to toxins and other biohazards when working outside the lab, as well as to simplify and increase sensitivity for many other types of immunological diagnostics and detection assays.
Dumoulin, Julie A.; Bown, Paul R.; Stewart, Sondra K.; Kennett, Diana; Mazzullo, Elsa K.
1992-01-01
Sediments from the Argo Abyssal Plain (AAP), northwest of Australia, are the oldest known from the Indian Ocean and were recovered from ODP Site 765 and DSDP Site 261. New biostratigraphic and sedimentologic data from these sites, as well as reinterpretations of earlier findings, indicate that basal sediments at both localities are of Late Jurassic age and delineate a history of starved sedimentation punctuated by periodic influx of calcareous pelagic turbidites.Biostratigraphy and correlation of Upper Jurassic-Lower Cretaceous sediments is based largely on calcareous nannofossils. Both sites yielded variably preserved nannofossil successions ranging from Tithonian to Hauterivian at Site 765 and Kimmeridgian to Hauterivian at Site 261. The nannofloras are comparable to those present in the European and Atlantic Boreal and Tethyan areas, but display important differences that reflect biogeographic differentiation. The Argo region is thought to have occupied a position at the southern limit of the Tethyan nannofloral realm, thus yielding both Tethyan and Austral biogeographic features.Sedimentary successions at the two sites are grossly similar, and differences largely reflect Site 765 's greater proximity to the continental margin. Jurassic sediments were deposited at rates of about 2 m/m.y. near the carbonate compensation depth (CCD) and contain winnowed concentrations of inoceramid prisms and nannofossils, redeposited layers rich in calcispheres and calcisphere debris, manganese nodules, and volcanic detritus. Lower Cretaceous and all younger sediments accumulated below the CCD at rates that were highest (about 20 m/m.y.) during mid-Cretaceous and Neogene time. Background sediment in this interval is noncalcareous claystone; turbidites dominate the sequence and are thicker and coarser grained at Site 765.AAP turbidites consist mostly of calcareous and siliceous biogenic components and volcanogenic smectite clay; they were derived from relatively deep parts of the continental margin that lay below the photic zone, but above the CCD. The Jurassic-Lower Cretaceous section is about the same thickness across the AAP; turbidites in this interval appear to have had multiple sources along the Australian margin. The Upper Cretaceous-Cenozoic section, however, is three times thicker at Site 765 than at Site 261; turbidites in this interval were derived predominantly from the south.Patterns of sedimentation across the AAP have been influenced by shifts in sea level, the CCD, and configuration of the continental margin. Major pulses of calcareous turbidite deposition occurred during Valanginian, Aptian, and Neogene time—all periods of eustatic lowstands and depressed CCD levels. Sediment redeposited on the AAP has come largely from the Australian outer shelf, continental slope, or rise, rather than the continent itself. Most terrigenous detritus was trapped in epicontinental basins that have flanked northwestern Australia since the early Mesozoic.
Saito, Akiko; Ooki, Akio; Nakamura, Takashi; Onodera, Shoko; Hayashi, Kamichika; Hasegawa, Daigo; Okudaira, Takahito; Watanabe, Katsuhito; Kato, Hiroshi; Onda, Takeshi; Watanabe, Akira; Kosaki, Kenjiro; Nishimura, Ken; Ohtaka, Manami; Nakanishi, Mahito; Sakamoto, Teruo; Yamaguchi, Akira; Sueishi, Kenji; Azuma, Toshifumi
2018-01-22
Runt-related transcription factor 2 (RUNX2) haploinsufficiency causes cleidocranial dysplasia (CCD) which is characterized by supernumerary teeth, short stature, clavicular dysplasia, and osteoporosis. At present, as a therapeutic strategy for osteoporosis, mesenchymal stem cell (MSC) transplantation therapy is performed in addition to drug therapy. However, MSC-based therapy for osteoporosis in CCD patients is difficult due to a reduction in the ability of MSCs to differentiate into osteoblasts resulting from impaired RUNX2 function. Here, we investigated whether induced pluripotent stem cells (iPSCs) properly differentiate into osteoblasts after repairing the RUNX2 mutation in iPSCs derived from CCD patients to establish normal iPSCs, and whether engraftment of osteoblasts derived from properly reverted iPSCs results in better regeneration in immunodeficient rat calvarial bone defect models. Two cases of CCD patient-derived induced pluripotent stem cells (CCD-iPSCs) were generated using retroviral vectors (OCT3/4, SOX2, KLF4, and c-MYC) or a Sendai virus SeVdp vector (KOSM302L). Reverted iPSCs were established using programmable nucleases, clustered regularly interspaced short palindromic repeats (CRISPR)/Cas-derived RNA-guided endonucleases, to correct mutations in CCD-iPSCs. The mRNA expressions of osteoblast-specific markers were analyzed using quantitative reverse-transcriptase polymerase chain reaction. iPSCs-derived osteoblasts were transplanted into rat calvarial bone defects, and bone regeneration was evaluated using microcomputed tomography analysis and histological analysis. Mutation analysis showed that both contained nonsense mutations: one at the very beginning of exon 1 and the other at the initial position of the nuclear matrix-targeting signal. The osteoblasts derived from CCD-iPSCs (CCD-OBs) expressed low levels of several osteoblast differentiation markers, and transplantation of these osteoblasts into calvarial bone defects created in rats with severe combined immunodeficiency showed poor regeneration. However, reverted iPSCs improved the abnormal osteoblast differentiation which resulted in much better engraftment into the rat calvarial bone defect. Taken together, these results demonstrate that patient-specific iPSC technology can not only provide a useful disease model to elucidate the role of RUNX2 in osteoblastic differentiation but also raises the tantalizing prospect that reverted iPSCs might provide a practical medical treatment for CCD.
Measurements of stress evolution during thin film deposition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chason, E.; Floro, J.A.
1996-05-01
We have developed a technique for measuring thin film stress during growth by monitoring the wafer curvature. By measuring the deflection of multiple parallel laser beams with a CCD detector, the sensivity to vibration is reduced and a radius of curvature limit of 4 km has been obtained in situ. This technique also enables us to obtain a 2-dimensional profile of the surface curvature from the simultaneous reflection of a rectangular array of beams. Results from the growth of SiG alloy films are presented to demonstrate the unique information that can be obtained during growth.
Wang, Yong; Ding, Guanqun; Gu, Tingting; Ding, Jing; Li, Yi
2017-08-01
Carotenoid dioxygenases, including 9-cis-epoxycarotenoid dioxygenases (NCEDs) and carotenoid cleavage dioxygenases (CCDs), can selectively cleave carotenoids into various apocarotenoid products that play important roles in fleshy fruit development and abiotic stress response. In this study, we identified 12 carotenoid dioxygenase genes in diploid strawberry Fragaria vesca, and explored their evolution with orthologous genes from nine other species. Phylogenetic analyses suggested that the NCED and CCDL groups moderately expanded during their evolution, whereas gene numbers of the CCD1, CCD4, CCD7, and CCD8 groups maintained conserved. We characterized the expression profiles of FveNCED and FveCCD genes during flower and fruit development, and in response to several abiotic stresses. FveNCED1 expression positively responded to osmotic, cold, and heat stresses, whereas FveNCED2 was only induced under cold stress. In contrast, FveNCED2 was the unique gene highly and continuously increasing in receptacle during fruit ripening, which co-occurred with the increase in endogenous abscisic acid (ABA) content previously reported in octoploid strawberry. The differential expression patterns suggested that FveNCED1 and FveNCED2 were key genes for ABA biosynthesis in abiotic stress responses and fruit ripening, respectively. FveCCD1 exhibited the highest expression in most stages of flower and fruit development, while the other FveCCDs were expressed in a subset of stages and tissues. Our study suggests distinct functions of FveNCED and FveCCD genes in fruit development and stress responses and lays a foundation for future study to understand the roles of these genes and their metabolites, including ABA and other apocarotenoid products, in the growth and development of strawberry.
SU-E-T-161: SOBP Beam Analysis Using Light Output of Scintillation Plate Acquired by CCD Camera.
Cho, S; Lee, S; Shin, J; Min, B; Chung, K; Shin, D; Lim, Y; Park, S
2012-06-01
To analyze Bragg-peak beams in SOBP (spread-out Bragg-peak) beam using CCD (charge-coupled device) camera - scintillation screen system. We separated each Bragg-peak beam using light output of high sensitivity scintillation material acquired by CCD camera and compared with Bragg-peak beams calculated by Monte Carlo simulation. In this study, CCD camera - scintillation screen system was constructed with a high sensitivity scintillation plate (Gd2O2S:Tb) and a right-angled prismatic PMMA phantom, and a Marlin F-201B, EEE-1394 CCD camera. SOBP beam irradiated by the double scattering mode of a PROTEUS 235 proton therapy machine in NCC is 8 cm width, 13 g/cm 2 range. The gain, dose rate and current of this beam is 50, 2 Gy/min and 70 nA, respectively. Also, we simulated the light output of scintillation plate for SOBP beam using Geant4 toolkit. We evaluated the light output of high sensitivity scintillation plate according to intergration time (0.1 - 1.0 sec). The images of CCD camera during the shortest intergration time (0.1 sec) were acquired automatically and randomly, respectively. Bragg-peak beams in SOBP beam were analyzed by the acquired images. Then, the SOBP beam used in this study was calculated by Geant4 toolkit and Bragg-peak beams in SOBP beam were obtained by ROOT program. The SOBP beam consists of 13 Bragg-peak beams. The results of experiment were compared with that of simulation. We analyzed Bragg-peak beams in SOBP beam using light output of scintillation plate acquired by CCD camera and compared with that of Geant4 simulation. We are going to study SOBP beam analysis using more effective the image acquisition technique. © 2012 American Association of Physicists in Medicine.
Tuan, Pham Anh; Park, Sang Un
2013-01-01
Carotenoid cleavage dioxygenases (CCDs) are a family of enzymes that catalyze the oxidative cleavage of carotenoids at various chain positions to form a broad spectrum of apocarotenoids, including aromatic substances, pigments and phytohormones. Using the rapid amplification of cDNA ends (RACE) PCR method, we isolated three cDNA-encoding CCDs (McCCD1, McCCD4, and McNCED) from Momordica charantia. Amino acid sequence alignments showed that they share high sequence identity with other orthologous genes. Quantitative real-time RT PCR (reverse transcriptase PCR) analysis revealed that the expression of McCCD1 and McCCD4 was highest in flowers, and lowest in roots and old leaves (O-leaves). During fruit maturation, the two genes displayed differential expression, with McCCD1 peaking at mid-stage maturation while McCCD4 showed the lowest expression at that stage. The mRNA expression level of McNCED, a key enzyme involved in abscisic acid (ABA) biosynthesis, was high during fruit maturation and further increased at the beginning of seed germination. When first-leaf stage plants of M. charantia were exposed to dehydration stress, McNCED mRNA expression was induced primarily in the leaves and, to a lesser extend, in roots and stems. McNCED expression was also induced by high temperature and salinity, while treatment with exogenous ABA led to a decrease. These results should be helpful in determining the substrates and cleavage sites catalyzed by CCD genes in M. charantia, and also in defining the roles of CCDs in growth and development, and in the plant's response to environmental stress. Copyright © 2012 Elsevier GmbH. All rights reserved.
Paleoenvironments of the Jurassic and Cretaceous Oceans: Selected Highlights
NASA Astrophysics Data System (ADS)
Ogg, J. G.
2007-12-01
There are many themes contributing to the sedimentation history of the Mesozoic oceans. This overview briefly examines the roles of the carbonate compensation depth (CCD) and the associated levels of atmospheric carbon dioxide, of the evolution of marine calcareous microplankton, of major transgressive and regressive trends, and of super-plume eruptions. Initiation of Atlantic seafloor spreading in the Middle Jurassic coincided with an elevated carbonate compensation depth (CCD) in the Pacific-Tethys mega-ocean. Organic-rich sediments that would become the oil wealth of regions from Saudi Arabia to the North Sea were deposited during a continued rise in CCD during the Oxfordian-early Kimmeridgian, which suggests a possible increase in carbon dioxide release by oceanic volcanic activity. Deep-sea deposits in near-equatorial settings are dominated by siliceous shales or cherts, which reflect the productivity of siliceous microfossils in the tropical surface waters. The end-Jurassic explosion in productivity by calcareous microplankton contributed to the lowering of the CCD and onset of the chalk ("creta") deposits that characterize the Tithonian and lower Cretaceous in all ocean basins. During the mid-Cretaceous, the eruption of enormous Pacific igneous provinces (Ontong Java Plateau and coeval edifices) increased carbon dioxide levels. The resulting rise in CCD terminated chalk deposition in the deep sea. The excess carbon was progressively removed in widespread black-shale deposits in the Atlantic basins and other regions - another major episode of oil source rock. A major long-term transgression during middle and late Cretaceous was accompanied by extensive chalk deposition on continental shelves and seaways while the oceanic CCD remained elevated. Pacific guyots document major oscillations (sequences) of global sea level superimposed on this broad highstand. The Cretaceous closed with a progressive sea-level regression and lowering of the CCD that again enabled widespread carbonate deposition in the deep sea.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Hsu-Pin; Hsu, Shu-Yuan; Wu, Wen-Ai
Highlights: •Pnn CCD domain functions as a dominant negative mutant regulating Pnn expression and function. •Pnn CCD mutant Tg mice have a muscle wasting phenotype during development and show dystrophic histological features. •Pnn mutant muscles are susceptible to slow fiber type gene transition and NEB reduction. •The Tg mouse generated by overexpression of the Pnn CCD domain displays many characteristics resembling NEB{sup +/−} mice. -- Abstract: Pinin (Pnn) is a nuclear speckle-associated SR-like protein. The N-terminal region of the Pnn protein sequence is highly conserved from mammals to insects, but the C-terminal RS domain-containing region is absent in lower species.more » The N-terminal coiled-coil domain (CCD) is, therefore, of interest not only from a functional point of view, but also from an evolutionarily standpoint. To explore the biological role of the Pnn CCD in a physiological context, we generated transgenic mice overexpressing Pnn mutant in skeletal muscle. We found that overexpression of the CCD reduces endogenous Pnn expression in cultured cell lines as well as in transgenic skeletal muscle fibers. Pnn mutant mice exhibited reduced body mass and impaired muscle function during development. Mutant skeletal muscles show dystrophic histological features with muscle fibers heavily loaded with centrally located myonuclei. Expression profiling and pathway analysis identified over-representation of genes in gene categories associated with muscle contraction, specifically those related to slow type fiber. In addition nebulin (NEB) expression level is repressed in Pnn mutant skeletal muscle. We conclude that Pnn downregulation in skeletal muscle causes a muscular dystrophic phenotype associated with NEB deficiency and the CCD domain is incapable of replacing full length Pnn in terms of functional capacity.« less
Effects of biomechanical forces on signaling in the cortical collecting duct (CCD).
Carrisoza-Gaytan, Rolando; Liu, Yu; Flores, Daniel; Else, Cindy; Lee, Heon Goo; Rhodes, George; Sandoval, Ruben M; Kleyman, Thomas R; Lee, Francis Young-In; Molitoris, Bruce; Satlin, Lisa M; Rohatgi, Rajeev
2014-07-15
An increase in tubular fluid flow rate (TFF) stimulates Na reabsorption and K secretion in the cortical collecting duct (CCD) and subjects cells therein to biomechanical forces including fluid shear stress (FSS) and circumferential stretch (CS). Intracellular MAPK and extracellular autocrine/paracrine PGE2 signaling regulate cation transport in the CCD and, at least in other systems, are affected by biomechanical forces. We hypothesized that FSS and CS differentially affect MAPK signaling and PGE2 release to modulate cation transport in the CCD. To validate that CS is a physiological force in vivo, we applied the intravital microscopic approach to rodent kidneys in vivo to show that saline or furosemide injection led to a 46.5 ± 2.0 or 170 ± 32% increase, respectively, in distal tubular diameter. Next, murine CCD (mpkCCD) cells were grown on glass or silicone coated with collagen type IV and subjected to 0 or 0.4 dyne/cm(2) of FSS or 10% CS, respectively, forces chosen based on prior biomechanical modeling of ex vivo microperfused CCDs. Cells exposed to FSS expressed an approximately twofold greater abundance of phospho(p)-ERK and p-p38 vs. static cells, while CS did not alter p-p38 and p-ERK expression compared with unstretched controls. FSS induced whereas CS reduced PGE2 release by ∼40%. In conclusion, FSS and CS differentially affect ERK and p38 activation and PGE2 release in a cell culture model of the CD. We speculate that TFF differentially regulates biomechanical signaling and, in turn, cation transport in the CCD. Copyright © 2014 the American Physiological Society.
Multiple diffraction in an icosahedral Al-Cu-Fe quasicrystal
NASA Astrophysics Data System (ADS)
Fan, C. Z.; Weber, Th.; Deloudi, S.; Steurer, W.
2011-07-01
In order to reveal its influence on quasicrystal structure analysis, multiple diffraction (MD) effects in an icosahedral Al-Cu-Fe quasicrystal have been investigated in-house on an Oxford Diffraction four-circle diffractometer equipped with an Onyx™ CCD area detector and MoKα radiation. For that purpose, an automated approach for Renninger scans (ψ-scans) has been developed. Two weak reflections were chosen as the main reflections (called P) in the present measurements. As is well known for periodic crystals, it is also observed for this quasicrystal that the intensity of the main reflection may significantly increase if the simultaneous (H) and the coupling (P-H) reflections are both strong, while there is no obvious MD effect if one of them is weak. The occurrence of MD events during ψ-scans has been studied based on an ideal structure model and the kinematical MD theory. The reliability of the approach is revealed by the good agreement between simulation and experiment. It shows that the multiple diffraction effect is quite significant.
CTK: A new CCD Camera at the University Observatory Jena
NASA Astrophysics Data System (ADS)
Mugrauer, M.
2009-05-01
The Cassegrain-Teleskop-Kamera (CTK) is a new CCD imager which is operated at the University Observatory Jena since begin of 2006. This article describes the main characteristics of the new camera. The properties of the CCD detector, the CTK image quality, as well as its detection limits for all filters are presented. Based on observations obtained with telescopes of the University Observatory Jena, which is operated by the Astrophysical Institute of the Friedrich-Schiller-University.
Astronomical Archive at Tartu Observatory
NASA Astrophysics Data System (ADS)
Annuk, K.
2007-10-01
Archiving astronomical data is important task not only at large observatories but also at small observatories. Here we describe the astronomical archive at Tartu Observatory. The archive consists of old photographic plate images, photographic spectrograms, CCD direct--images and CCD spectroscopic data. The photographic plate digitizing project was started in 2005. An on-line database (based on MySQL) was created. The database includes CCD data as well photographic data. A PHP-MySQL interface was written for access to all data.
López-Ráez, Juan A; Fernández, Iván; García, Juan M; Berrio, Estefanía; Bonfante, Paola; Walter, Michael H; Pozo, María J
2015-01-01
Apocarotenoids are a class of compounds that play important roles in nature. In recent years, a prominent role for these compounds in arbuscular mycorrhizal (AM) symbiosis has been shown. They are derived from carotenoids by the action of the carotenoid cleavage dioxygenase (CCD) enzyme family. In the present study, using tomato as a model, the spatio-temporal expression pattern of the CCD genes during AM symbiosis establishment and functioning was investigated. In addition, the levels of the apocarotenoids strigolactones (SLs), C13 α-ionol and C14 mycorradicin (C13/C14) derivatives were analyzed. The results suggest an increase in SLs promoted by the presence of the AM fungus at the early stages of the interaction, which correlated with an induction of the SL biosynthesis gene SlCCD7. At later stages, induction of SlCCD7 and SlCCD1 expression in arbusculated cells promoted the production of C13/C14 apocarotenoid derivatives. We show here that the biosynthesis of apocarotenoids during AM symbiosis is finely regulated throughout the entire process at the gene expression level, and that CCD7 constitutes a key player in this regulation. Once the symbiosis is established, apocarotenoid flux would be turned towards the production of C13/C14 derivatives, thus reducing SL biosynthesis and maintaining a functional symbiosis. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Multiple image encryption scheme based on pixel exchange operation and vector decomposition
NASA Astrophysics Data System (ADS)
Xiong, Y.; Quan, C.; Tay, C. J.
2018-02-01
We propose a new multiple image encryption scheme based on a pixel exchange operation and a basic vector decomposition in Fourier domain. In this algorithm, original images are imported via a pixel exchange operator, from which scrambled images and pixel position matrices are obtained. Scrambled images encrypted into phase information are imported using the proposed algorithm and phase keys are obtained from the difference between scrambled images and synthesized vectors in a charge-coupled device (CCD) plane. The final synthesized vector is used as an input in a random phase encoding (DRPE) scheme. In the proposed encryption scheme, pixel position matrices and phase keys serve as additional private keys to enhance the security of the cryptosystem which is based on a 4-f system. Numerical simulations are presented to demonstrate the feasibility and robustness of the proposed encryption scheme.
Ando, Yoriko; Sakurai, Takashi; Koida, Kowa; Tei, Hajime; Hida, Akiko; Nakao, Kazuki; Natsume, Mistuo; Numano, Rika
2016-01-01
Bioluminescence imaging (BLI) is used in biomedical research to monitor biological processes within living organisms. Recently, fiber bundles with high transmittance and density have been developed to detect low light with high resolution. Therefore, we have developed a bundled-fiber-coupled microscope with a highly sensitive cooled-CCD camera that enables the BLI of organs within the mouse body. This is the first report of in vivo BLI of the brain and multiple organs in luciferase-reporter mice using bundled-fiber optics. With reflectance imaging, the structures of blood vessels and organs can be seen clearly with light illumination, and it allowed identification of the structural details of bioluminescence images. This technique can also be applied to clinical diagnostics in a low invasive manner. PMID:27231601
Yang, Yuan-Zheng; Chang, Yu; Hu, Yuan-Man; Liu, Miao; Li, Yue-Hui
2011-06-01
To timely and accurately acquire the spatial distribution pattern of wetlands is of significance for the dynamic monitoring, conservation, and sustainable utilization of wetlands. The small remote sensing satellite constellations A/B stars (HJ-1A/1B stars) for environmental hazards were launched by China for monitoring terrestrial resources, which could provide a new data source of remote sensing image acquisition for retrieving wetland types. Taking Liaohe Delta as a case, this paper compared the accuracy of wetland classification map and the area of each wetland type retrieved from CCD data (HJ CCD data) and TM5 data, and validated and explored the applicability and the applied potential of HJ CCD data in wetland resources dynamic monitoring. The results showed that HJ CCD data could completely replace Landsat TM5 data in feature extraction and remote sensing classification. In real-time monitoring, due to its 2 days of data acquisition cycle, HJ CCD data had the priority to Landsat TM5 data (16 days of data acquisition cycle).
Replacing a technology - The Large Space Telescope and CCDs
NASA Astrophysics Data System (ADS)
Smith, R. W.; Tatarewicz, J. H.
1985-07-01
The technological improvements, design choices and mission goals which led to the inclusion of CCD detectors in the wide field camera of the Large Space Telescope (LST) to be launched by the STS are recounted. Consideration of CCD detectors began before CCDs had seen wide astronomical applications. During planning for the ST, in the 1960s, photographic methods and a vidicon were considered, and seemed feasible provided that periodic manual maintenance could be performed. The invention of CCDs was first reported in 1970 and by 1973 the CCDs were receiving significant attention as potential detectors instead of a vidicon, which retained its own technological challenges. The CCD format gained new emphasis when success was achieved in developments for planetary-imaging spacecraft. The rapidity of progress in CCD capabilities, coupled with the continued shortcomings of the vidicon, resulted in a finalized choice for a CCD device by 1977. The decision was also prompted by continuing commercial and military interest in CCDs, which was spurring the development of the technology and improving the sensitivities and reliability while lowering the costs.
Three-dimensional charge coupled device
Conder, Alan D.; Young, Bruce K. F.
1999-01-01
A monolithic three dimensional charged coupled device (3D-CCD) which utilizes the entire bulk of the semiconductor for charge generation, storage, and transfer. The 3D-CCD provides a vast improvement of current CCD architectures that use only the surface of the semiconductor substrate. The 3D-CCD is capable of developing a strong E-field throughout the depth of the semiconductor by using deep (buried) parallel (bulk) electrodes in the substrate material. Using backside illumination, the 3D-CCD architecture enables a single device to image photon energies from the visible, to the ultra-violet and soft x-ray, and out to higher energy x-rays of 30 keV and beyond. The buried or bulk electrodes are electrically connected to the surface electrodes, and an E-field parallel to the surface is established with the pixel in which the bulk electrodes are located. This E-field attracts charge to the bulk electrodes independent of depth and confines it within the pixel in which it is generated. Charge diffusion is greatly reduced because the E-field is strong due to the proximity of the bulk electrodes.
Final Report, January 1991 - July 1992
NASA Astrophysics Data System (ADS)
Ferrara, Jon
1992-07-01
This report covers final schedules, expenses and billings, monthly reports, testing, and deliveries for this contract. The goal of the detector development program for the Solar and Heliospheric Spacecraft (SOHO) EUV Imaging Telescope (EIT) is an Extreme UltraViolet (EUV) CCD (Change Collecting Device) camera. As a part of the CCD screening effort, the quantum efficiency (QE) of a prototype CCD has been measured in the NRL EUV laboratory over the wavelength range of 256 to 735 Angstroms. A simplified model has been applied to these QE measurements to illustrate the relevant physical processes that determine the performance of the detector. The charge transfer efficiency (CTE) characteristics of the Tektronix 1024 X 1024 CCD being developed for STIS/SOHO space imaging applications have been characterized at different signal levels, operating conditions, and temperatures using a variety of test methods. A number of CCD's have been manufactured using processing techniques developed to improve CTE, and test results on these devices will be used in determining the final chip design. In this paper, we discuss the CTE test methods used and present the results and conclusions of these tests.
Westbrook, John D.; Shao, Chenghua; Feng, Zukang; Zhuravleva, Marina; Velankar, Sameer; Young, Jasmine
2015-01-01
Summary: The Chemical Component Dictionary (CCD) is a chemical reference data resource that describes all residue and small molecule components found in Protein Data Bank (PDB) entries. The CCD contains detailed chemical descriptions for standard and modified amino acids/nucleotides, small molecule ligands and solvent molecules. Each chemical definition includes descriptions of chemical properties such as stereochemical assignments, chemical descriptors, systematic chemical names and idealized coordinates. The content, preparation, validation and distribution of this CCD chemical reference dataset are described. Availability and implementation: The CCD is updated regularly in conjunction with the scheduled weekly release of new PDB structure data. The CCD and amino acid variant reference datasets are hosted in the public PDB ftp repository at ftp://ftp.wwpdb.org/pub/pdb/data/monomers/components.cif.gz, ftp://ftp.wwpdb.org/pub/pdb/data/monomers/aa-variants-v1.cif.gz, and its mirror sites, and can be accessed from http://wwpdb.org. Contact: jwest@rcsb.rutgers.edu. Supplementary information: Supplementary data are available at Bioinformatics online. PMID:25540181
Process for fabricating a charge coupled device
Conder, Alan D.; Young, Bruce K. F.
2002-01-01
A monolithic three dimensional charged coupled device (3D-CCD) which utilizes the entire bulk of the semiconductor for charge generation, storage, and transfer. The 3D-CCD provides a vast improvement of current CCD architectures that use only the surface of the semiconductor substrate. The 3D-CCD is capable of developing a strong E-field throughout the depth of the semiconductor by using deep (buried) parallel (bulk) electrodes in the substrate material. Using backside illumination, the 3D-CCD architecture enables a single device to image photon energies from the visible, to the ultra-violet and soft x-ray, and out to higher energy x-rays of 30 keV and beyond. The buried or bulk electrodes are electrically connected to the surface electrodes, and an E-field parallel to the surface is established with the pixel in which the bulk electrodes are located. This E-field attracts charge to the bulk electrodes independent of depth and confines it within the pixel in which it is generated. Charge diffusion is greatly reduced because the E-field is strong due to the proximity of the bulk electrodes.
Quantum efficiency measurement of the Transiting Exoplanet Survey Satellite (TESS) CCD detectors
NASA Astrophysics Data System (ADS)
Krishnamurthy, A.; Villasenor, J.; Thayer, C.; Kissel, S.; Ricker, G.; Seager, S.; Lyle, R.; Deline, A.; Morgan, E.; Sauerwein, T.; Vanderspek, R.
2016-07-01
Very precise on-ground characterization and calibration of TESS CCD detectors will significantly assist in the analysis of the science data from the mission. An accurate optical test bench with very high photometric stability has been developed to perform precise measurements of the absolute quantum efficiency. The setup consists of a vacuum dewar with a single MIT Lincoln Lab CCID-80 device mounted on a cold plate with the calibrated reference photodiode mounted next to the CCD. A very stable laser-driven light source is integrated with a closed-loop intensity stabilization unit to control variations of the light source down to a few parts-per-million when averaged over 60 s. Light from the stabilization unit enters a 20 inch integrating sphere. The output light from the sphere produces near-uniform illumination on the cold CCD and on the calibrated reference photodiode inside the dewar. The ratio of the CCD and photodiode signals provides the absolute quantum efficiency measurement. The design, key features, error analysis, and results from the test campaign are presented.
Raimondi, V; Agati, G; Cecchi, G; Gomoiu, I; Lognoli, D; Palombi, L
2009-12-07
An optical epifluorescence microscope, coupled to a CCD camera, a standard webcam and a microspectrofluorimeter, are used to record in vivo real-time changes in the autofluorescence of spores and hyphae in Aspergillus niger, a fungus containing melanin, while exposed to UV irradiation. The results point out major changes in both signal intensity and the spectral shape of the autofluorescence signal after only few minutes of exposure, and can contribute to the interpretation of data obtained with other fluorescence techniques, including those, such as GPF labeling, in which endogenous fluorophores constitute a major disturbance.
Software manual for operating particle displacement tracking data acquisition and reduction system
NASA Technical Reports Server (NTRS)
Wernet, Mark P.
1991-01-01
The software manual is presented. The necessary steps required to record, analyze, and reduce Particle Image Velocimetry (PIV) data using the Particle Displacement Tracking (PDT) technique are described. The new PDT system is an all electronic technique employing a CCD video camera and a large memory buffer frame-grabber board to record low velocity (less than or equal to 20 cm/s) flows. Using a simple encoding scheme, a time sequence of single exposure images are time coded into a single image and then processed to track particle displacements and determine 2-D velocity vectors. All the PDT data acquisition, analysis, and data reduction software is written to run on an 80386 PC.
SPECKLE INTERFEROMETRY AT THE U.S. NAVAL OBSERVATORY. XVIII
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason, Brian D.; Hartkopf, William I.; Friedman, Elizabeth A., E-mail: bdm@usno.navy.mil, E-mail: wih@usno.navy.mil, E-mail: efriedman09@ucla.edu
2012-05-15
The results of 2490 intensified CCD observations of double stars, made with the 26 inch refractor of the U.S. Naval Observatory, are presented. Each observation of a system represents a combination of over 2000 short-exposure images. These observations are averaged into 1462 mean relative positions and range in separation from 0.''56 to 71.''80, with a mean separation of 14.''81. This is the 18th in this series of papers and covers the period 2011 January 3 through 2011 December 18. Also presented are four pairs which are resolved for the first time, thirteen other pairs which appear to be lost, andmore » linear elements for four additional pairs.« less
Canning, John; Lau, Angelica; Naqshbandi, Masood; Petermann, Ingemar; Crossley, Maxwell J.
2011-01-01
The blue OLED emission from a mobile phone was characterised, revealing a sharp emission band centred at λ = 445 nm with a 3dB bandwidth Δλ ∼ 20 nm. It was used to excite Rhodamine 123 doped within a “giant” mesostructured silica sphere during fabrication through evaporative self-assembly of silica nanoparticles. Fluorescence was able to be detected using a standard optical microscope fitted with a green transmission pass filter and cooled CCD and with 1 ms exposure time demonstrating the potential of mobile platforms as the basis for portable diagnostics in the field. PMID:22164002
Design on the x-ray oral digital image display card
NASA Astrophysics Data System (ADS)
Wang, Liping; Gu, Guohua; Chen, Qian
2009-10-01
According to the main characteristics of X-ray imaging, the X-ray display card is successfully designed and debugged using the basic principle of correlated double sampling (CDS) and combined with embedded computer technology. CCD sensor drive circuit and the corresponding procedures have been designed. Filtering and sampling hold circuit have been designed. The data exchange with PC104 bus has been implemented. Using complex programmable logic device as a device to provide gating and timing logic, the functions which counting, reading CPU control instructions, corresponding exposure and controlling sample-and-hold have been completed. According to the image effect and noise analysis, the circuit components have been adjusted. And high-quality images have been obtained.
Speckle Interferometry at the U.S. Naval Observatory. XIX
NASA Astrophysics Data System (ADS)
Mason, Brian D.; Hartkopf, William I.; Hurowitz, Haley M.
2013-09-01
The results of 2916 intensified CCD observations of double stars, made with the 26 inch refractor of the U.S. Naval Observatory, are presented. Each observation of a system represents a combination of over two thousand short-exposure images. These observations are averaged into 1584 mean relative positions and range in separation from 0.''54 to 98.''09, with a median separation of 11.''73. This is the 19th in this series of papers and covers the period 2012 January 5 through 2012 December 18. Also presented are 10 pairs that are reported for the first time, 17 pairs that appear to be lost, linear elements for 18 pairs, and orbital elements for 2 additional pairs.
NASA Astrophysics Data System (ADS)
Hayashida, T.,; Yonai, J.; Kitamura, K.; Arai, T.; Kurita, T.; Tanioka, K.; Maruyama, H.; Etoh, T. Goji; Kitagawa, S.; Hatade, K.; Yamaguchi, T.; Takeuchi, H.; Iida, K.
2008-02-01
We are advancing the development of ultrahigh-speed, high-sensitivity CCDs for broadcast use that are capable of capturing smooth slow-motion videos in vivid colors even where lighting is limited, such as at professional baseball games played at night. We have already developed a 300,000 pixel, ultrahigh-speed CCD, and a single CCD color camera that has been used for sports broadcasts and science programs using this CCD. However, there are cases where even higher sensitivity is required, such as when using a telephoto lens during a baseball broadcast or a high-magnification microscope during science programs. This paper provides a summary of our experimental development aimed at further increasing the sensitivity of CCDs using the light-collecting effects of a microlens array.
Tests of commercial colour CMOS cameras for astronomical applications
NASA Astrophysics Data System (ADS)
Pokhvala, S. M.; Reshetnyk, V. M.; Zhilyaev, B. E.
2013-12-01
We present some results of testing commercial colour CMOS cameras for astronomical applications. Colour CMOS sensors allow to perform photometry in three filters simultaneously that gives a great advantage compared with monochrome CCD detectors. The Bayer BGR colour system realized in colour CMOS sensors is close to the astronomical Johnson BVR system. The basic camera characteristics: read noise (e^{-}/pix), thermal noise (e^{-}/pix/sec) and electronic gain (e^{-}/ADU) for the commercial digital camera Canon 5D MarkIII are presented. We give the same characteristics for the scientific high performance cooled CCD camera system ALTA E47. Comparing results for tests of Canon 5D MarkIII and CCD ALTA E47 show that present-day commercial colour CMOS cameras can seriously compete with the scientific CCD cameras in deep astronomical imaging.
Ion-molecule calculation of the abundance ratio of CCD to CCH in dense interstellar clouds
NASA Technical Reports Server (NTRS)
Herbst, Eric; Adams, Nigel G.; Smith, David; Defrees, D. J.
1987-01-01
Laboratory measurements and calculations have been performed to determine the abundance ratio of the deuterated ethynyl radical (CCD) to the normal radical (CCH) which can be achieved in dense interstellar clouds via isotopic fractionation in the C2H2(+) (HD)=C2HD(+)(H2) system of reactions. According to this limited treatment, the CCD/CCH abundance ratio which can be attained is in the range 0.02-0.03 for the Orion molecular cloud and 0.0l-0.02 for TMC-1. These ranges of numbers are in reasonable agreement with the observed values in Orion and TMC-1. However, the analysis of the CCD/CCH abundance ratio is complicated via the presence of competing fractionation mechanisms, especially in the low-temperature source TMC-1.
Solid state television camera (CCD-buried channel)
NASA Technical Reports Server (NTRS)
1976-01-01
The development of an all solid state television camera, which uses a buried channel charge coupled device (CCD) as the image sensor, was undertaken. A 380 x 488 element CCD array is utilized to ensure compatibility with 525 line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (a) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (b) techniques for the elimination or suppression of CCD blemish effects, and (c) automatic light control and video gain control (i.e., ALC and AGC) techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a deliverable solid state TV camera which addressed the program requirements for a prototype qualifiable to space environment conditions.
Solid state television camera (CCD-buried channel), revision 1
NASA Technical Reports Server (NTRS)
1977-01-01
An all solid state television camera was designed which uses a buried channel charge coupled device (CCD) as the image sensor. A 380 x 488 element CCD array is utilized to ensure compatibility with 525-line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (1) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (2) techniques for the elimination or suppression of CCD blemish effects, and (3) automatic light control and video gain control techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a deliverable solid state TV camera which addressed the program requirements for a prototype qualifiable to space environment conditions.
Solid state, CCD-buried channel, television camera study and design
NASA Technical Reports Server (NTRS)
Hoagland, K. A.; Balopole, H.
1976-01-01
An investigation of an all solid state television camera design, which uses a buried channel charge-coupled device (CCD) as the image sensor, was undertaken. A 380 x 488 element CCD array was utilized to ensure compatibility with 525 line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (a) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (b) techniques for the elimination or suppression of CCD blemish effects, and (c) automatic light control and video gain control techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a design which addresses the program requirements for a deliverable solid state TV camera.
Feng, Wei; Zhang, Fumin; Qu, Xinghua; Zheng, Shiwei
2016-01-01
High-speed photography is an important tool for studying rapid physical phenomena. However, low-frame-rate CCD (charge coupled device) or CMOS (complementary metal oxide semiconductor) camera cannot effectively capture the rapid phenomena with high-speed and high-resolution. In this paper, we incorporate the hardware restrictions of existing image sensors, design the sampling functions, and implement a hardware prototype with a digital micromirror device (DMD) camera in which spatial and temporal information can be flexibly modulated. Combined with the optical model of DMD camera, we theoretically analyze the per-pixel coded exposure and propose a three-element median quicksort method to increase the temporal resolution of the imaging system. Theoretically, this approach can rapidly increase the temporal resolution several, or even hundreds, of times without increasing bandwidth requirements of the camera. We demonstrate the effectiveness of our method via extensive examples and achieve 100 fps (frames per second) gain in temporal resolution by using a 25 fps camera. PMID:26959023
Feng, Wei; Zhang, Fumin; Qu, Xinghua; Zheng, Shiwei
2016-03-04
High-speed photography is an important tool for studying rapid physical phenomena. However, low-frame-rate CCD (charge coupled device) or CMOS (complementary metal oxide semiconductor) camera cannot effectively capture the rapid phenomena with high-speed and high-resolution. In this paper, we incorporate the hardware restrictions of existing image sensors, design the sampling functions, and implement a hardware prototype with a digital micromirror device (DMD) camera in which spatial and temporal information can be flexibly modulated. Combined with the optical model of DMD camera, we theoretically analyze the per-pixel coded exposure and propose a three-element median quicksort method to increase the temporal resolution of the imaging system. Theoretically, this approach can rapidly increase the temporal resolution several, or even hundreds, of times without increasing bandwidth requirements of the camera. We demonstrate the effectiveness of our method via extensive examples and achieve 100 fps (frames per second) gain in temporal resolution by using a 25 fps camera.
VizieR Online Data Catalog: Redshifts of galaxies in Abell 1351 field (Barrena+, 2014)
NASA Astrophysics Data System (ADS)
Barrena, R.; Girardi, M.; Boschin, W.; de Grandi, S.; Rossetti, M.
2015-03-01
Multi-object spectroscopic (MOS) observations of A1351 were carried out at the TNG on 2010 March 10. We used DOLORES/MOS with the LR-B Grism 1, yielding a dispersion of 187Å/mm. We used the 2048x2048 pixel E2V CCD, with a pixel size of 13.5um. In total, we observed four MOS masks including 143 slits. For each mask, the exposure time was 3x1800s. We had already observed A1351 field with the Wide Field Camera (WFC), mounted at the prime focus of the 2.5m INT telescope. We took exposures of 9x600s and 9x300s in B and R Harris filters in photometric conditions and 1.2-arcsec seeing. However, we used SDSS-DR7 data because a greater number of photometric bands are available, which allows an accurate colour analysis. INT and SDSS-DR7 photometric data are very similar. The completeness magnitude is r'=20.8. (1 data file).
Large-mirror testing facility at the National Optical Astronomy Observatories.
NASA Astrophysics Data System (ADS)
Barr, L. D.; Coudé du Foresto, V.; Fox, J.; Poczulp, G. A.; Richardson, J.; Roddier, C.; Roddier, F.
1991-09-01
A method for testing the surfaces of large mirrors has been developed to be used even when conditions of vibration and thermal turbulence in the light path cannot be eliminated. The full aperture of the mirror under test is examined by means of a scatterplate interferometer that has the property of being a quasi-common-path method, although any means for obtaining interference fringes will do. The method uses a remotely operated CCD camera system to record the fringe pattern from the workpiece. The typical test is done with a camera exposure of about a millisecond to "freeze" the fringe pattern on the detector. Averaging up to 10 separate exposures effectively eliminates the turbulence effects. The method described provides the optician with complete numerical information and visual plots for the surface under test and the diffracted image the method will produce, all within a few minutes, to an accuracy of 0.01 μm measured peak-to-valley.
NASA Technical Reports Server (NTRS)
Bozyan, Elizabeth P.; Hemenway, Paul D.; Argue, A. Noel
1990-01-01
Observations of a set of 89 extragalactic objects (EGOs) will be made with the Hubble Space Telescope Fine Guidance Sensors and Planetary Camera in order to link the HIPPARCOS Instrumental System to an extragalactic coordinate system. Most of the sources chosen for observation contain compact radio sources and stellarlike nuclei; 65 percent are optical variables beyond a 0.2 mag limit. To ensure proper exposure times, accurate mean magnitudes are necessary. In many cases, the average magnitudes listed in the literature were not adequate. The literature was searched for all relevant photometric information for the EGOs, and photometric parameters were derived, including mean magnitude, maximum range, and timescale of variability. This paper presents the results of that search and the parameters derived. The results will allow exposure times to be estimated such that an observed magnitude different from the tabular magnitude by 0.5 mag in either direction will not degrade the astrometric centering ability on a Planetary Camera CCD frame.
Flexcam Image Capture Viewing and Spot Tracking
NASA Technical Reports Server (NTRS)
Rao, Shanti
2008-01-01
Flexcam software was designed to allow continuous monitoring of the mechanical deformation of the telescope structure at Palomar Observatory. Flexcam allows the user to watch the motion of a star with a low-cost astronomical camera, to measure the motion of the star on the image plane, and to feed this data back into the telescope s control system. This automatic interaction between the camera and a user interface facilitates integration and testing. Flexcam is a CCD image capture and analysis tool for the ST-402 camera from Santa Barbara Instruments Group (SBIG). This program will automatically take a dark exposure and then continuously display corrected images. The image size, bit depth, magnification, exposure time, resolution, and filter are always displayed on the title bar. Flexcam locates the brightest pixel and then computes the centroid position of the pixels falling in a box around that pixel. This tool continuously writes the centroid position to a network file that can be used by other instruments.
NASA Technical Reports Server (NTRS)
Traub, W. A.
1984-01-01
The first physical demonstration of the principle of image reconstruction using a set of images from a diffraction-blurred elongated aperture is reported. This is an optical validation of previous theoretical and numerical simulations of the COSMIC telescope array (coherent optical system of modular imaging collectors). The present experiment utilizes 17 diffraction blurred exposures of a laboratory light source, as imaged by a lens covered by a narrow-slit aperture; the aperture is rotated 10 degrees between each exposure. The images are recorded in digitized form by a CCD camera, Fourier transformed, numerically filtered, and added; the sum is then filtered and inverse Fourier transformed to form the final image. The image reconstruction process is found to be stable with respect to uncertainties in values of all physical parameters such as effective wavelength, rotation angle, pointing jitter, and aperture shape. Future experiments will explore the effects of low counting rates, autoguiding on the image, various aperture configurations, and separated optics.
An Overview of the CBERS-2 Satellite and Comparison of the CBERS-2 CCD Data with the L5 TM Data
NASA Technical Reports Server (NTRS)
Chandler, Gyanesh
2007-01-01
CBERS satellite carries on-board a multi sensor payload with different spatial resolutions and collection frequencies. HRCCD (High Resolution CCD Camera), IRMSS (Infrared Multispectral Scanner), and WFI (Wide-Field Imager). The CCD and the WFI camera operate in the VNIR regions, while the IRMSS operates in SWIR and thermal region. In addition to the imaging payload, the satellite carries a Data Collection System (DCS) and Space Environment Monitor (SEM).
Design of a CCD Camera for Space Surveillance
2016-03-05
Laboratory fabricated CCID-51M, a 2048x1024 pixel Charge Couple Device (CCD) imager. [1] The mission objective is to observe and detect satellites in...phased to transfer the charge to the outputs. An electronic shutter is created by having an equal area of pixels covered by an opaque metal mask. The...Figure 4 CDS Timing Diagram By design the CCD readout rate is 400 KHz. This rate was chosen so reading the 2E6 pixels from one output is less than
Perkins, David Nikolaus; Gonzales, Antonio I
2014-04-08
A set of co-registered coherent change detection (CCD) products is produced from a set of temporally separated synthetic aperture radar (SAR) images of a target scene. A plurality of transformations are determined, which transformations are respectively for transforming a plurality of the SAR images to a predetermined image coordinate system. The transformations are used to create, from a set of CCD products produced from the set of SAR images, a corresponding set of co-registered CCD products.
NASA Astrophysics Data System (ADS)
Lyuty, V. M.; Abdullayev, B. I.; Alekberov, I. A.; Gulmaliyev, N. I.; Mikayilov, Kh. M.; Rustamov, B. N.
2009-12-01
Short description of optical and electric scheme of CCD photometer with camera U-47 installed on the Cassegrain focus of ZEISS-600 telescope of the ShAO NAS Azerbaijan is provided. The reducer of focus with factor of reduction 1.7 is applied. It is calculated equivalent focal distances of a telescope with a focus reducer. General calculations of optimum distance from focal plane and t sizes of optical filters of photometer are presented.
Development of CCD imaging sensors for space applications, phase 1
NASA Technical Reports Server (NTRS)
Antcliffe, G. A.
1975-01-01
The results of an experimental investigation to develop a large area charge coupled device (CCD) imager for space photography applications are described. Details of the design and processing required to achieve 400 X 400 imagers are presented together with a discussion of the optical characterization techniques developed for this program. A discussion of several aspects of large CCD performance is given with detailed test reports. The areas covered include dark current, uniformity of optical response, square wave amplitude response, spectral responsivity and dynamic range.
A large longitudinal cohort study designed to evaluate the association between children's exposures to environmental agents and health outcomes presents many challenges for exposure monitoring. Exposure of the child must be measured for multiple chemicals through multiple path...
CCD Times of Minima of Selected Eclipsing Binaries
NASA Astrophysics Data System (ADS)
Zejda, Miloslav
2004-12-01
682 CCD minima observations of 259 eclipsing binaries made mainly by author are presented. The observed stars were chosen mainly from catalogue BRKA of observing programme of BRNO-Variable Star Section of CAS.
NASA Technical Reports Server (NTRS)
Gassaway, J. D.
1976-01-01
Two approaches have been taken to study CCD's and some of their fundamental limitations. First a numerical analysis approach has been developed to solve the coupled transport and Poisson's equation for a thorough analysis of charge transfer in a CCD structure. The approach is formulated by treating the minority carriers as a surface distribution at the Si-SiO2 interface and setting up coupled difference equations for the charge and the potential. The SOR method is proposed for solving the two dimensional Poisson's equation for the potential. Methods are suggested for handling the discontinuities to improve convergence. Second, CCD shift registers were fabricated with parameters which should allow complete charge transfer independent of the transfer electrode gap width. A test instrument was designed and constructed which can be used to test this, or any similar, three phase CCD shift register.
NASA Astrophysics Data System (ADS)
Upputuri, Paul Kumar; Pramanik, Manojit
2018-02-01
Phase shifting white light interferometry (PSWLI) has been widely used for optical metrology applications because of their precision, reliability, and versatility. White light interferometry using monochrome CCD makes the measurement process slow for metrology applications. WLI integrated with Red-Green-Blue (RGB) CCD camera is finding imaging applications in the fields optical metrology and bio-imaging. Wavelength dependent refractive index profiles of biological samples were computed from colour white light interferograms. In recent years, whole-filed refractive index profiles of red blood cells (RBCs), onion skin, fish cornea, etc. were measured from RGB interferograms. In this paper, we discuss the bio-imaging applications of colour CCD based white light interferometry. The approach makes the measurement faster, easier, cost-effective, and even dynamic by using single fringe analysis methods, for industrial applications.
Noise analysis for CCD-based ultraviolet and visible spectrophotometry.
Davenport, John J; Hodgkinson, Jane; Saffell, John R; Tatam, Ralph P
2015-09-20
We present the results of a detailed analysis of the noise behavior of two CCD spectrometers in common use, an AvaSpec-3648 CCD UV spectrometer and an Ocean Optics S2000 Vis spectrometer. Light sources used include a deuterium UV/Vis lamp and UV and visible LEDs. Common noise phenomena include source fluctuation noise, photoresponse nonuniformity, dark current noise, fixed pattern noise, and read noise. These were identified and characterized by varying light source, spectrometer settings, or temperature. A number of noise-limiting techniques are proposed, demonstrating a best-case spectroscopic noise equivalent absorbance of 3.5×10(-4) AU for the AvaSpec-3648 and 5.6×10(-4) AU for the Ocean Optics S2000 over a 30 s integration period. These techniques can be used on other CCD spectrometers to optimize performance.
Realization of Vilnius UPXYZVS photometric system for AltaU42 CCD camera at the MAO NAS of Ukraine
NASA Astrophysics Data System (ADS)
Vid'Machenko, A. P.; Andruk, V. M.; Samoylov, V. S.; Delets, O. S.; Nevodovsky, P. V.; Ivashchenko, Yu. M.; Kovalchuk, G. U.
2005-06-01
The description of two-inch glass filters of the Vilnius UPXYZVS photometric system, which are made at the Main Astronomical Observatory of NAS of Ukraine for AltaU42 CCD camera with format of 2048×2048 pixels, is presented in the paper. Reaction curves of instrumental system are shown. Estimations of minimal star's magnitudes for each filter's band in comparison with the visual V one are obtained. New software for automation of CCD frames processing is developed in program shell of LINUX/MIDAS/ROMAFOT. It is planned to carry out observations with the purpose to create the catalogue of primary UPXYZVS CCD standards in selected field of the sky for some radio-sources, globular and open clusters, etc. Numerical estimations of astrometric and photometric accuracy are obtained.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aoyagi, Yasuyuki; Department of Genome Research and Clinical Application, Graduate School of Medicine, Chiba University, Chiba; Kuroda, Masayuki, E-mail: kurodam@faculty.chiba-u.jp
Adipose tissue is expected to provide a source of cells for protein replacement therapies via auto-transplantation. However, the conditioning of the environment surrounding the transplanted adipocytes for their long-term survival and protein secretion properties has not been established. We have recently developed a preparation procedure for preadipocytes, ceiling culture-derived proliferative adipocytes (ccdPAs), as a therapeutic gene vehicle suitable for stable gene product secretion. We herein report the results of our evaluation of using fibrin glue as a scaffold for the transplanted ccdPAs for the expression of a transduced gene in a three-dimensional culture system. The ccdPAs secreted the functional proteinmore » translated from an exogenously transduced gene, as well as physiological adipocyte proteins, and the long viability of ccdPAs (up to 84 days) was dependent on the fibrinogen concentrations. The ccdPAs spontaneously accumulated lipid droplets, and their expression levels of the transduced exogenous gene with its product were maintained for at least 56 days. The fibrinogen concentration modified the adipogenic differentiation of ccdPAs and their exogenous gene expression levels, and the levels of exogenously transduced gene expression at the different fibrinogen concentrations were dependent on the extent of adipogenic differentiation in the gel. These results indicate that fibrin glue helps to maintain the high adipogenic potential of cultured adipocytes after passaging in a 3D culture system, and suggests that once they are successfully implanted at the transplantation site, the cells exhibit increased expression of the transduced gene with adipogenic differentiation.« less
Goudsmit, Miriam; Uysal-Bozkir, Özgül; Parlevliet, Juliette L; van Campen, Jos P C M; de Rooij, Sophia E; Schmand, Ben
2017-03-01
Currently, approximately 3.9% of the European population are non-EU citizens, and a large part of these people are from "non-Western" societies, such as Turkey and Morocco. For various reasons, the incidence of dementia in this group is expected to increase. However, cognitive testing is challenging due to language barriers and low education and/or illiteracy. The newly developed Cross-Cultural Dementia Screening (CCD) can be administered without an interpreter. It contains three subtests that assess memory, mental speed, and executive function. We hypothesized the CCD to be a culture-fair test that could discriminate between demented patients and cognitively healthy controls. To test this hypothesis, 54 patients who had probable dementia were recruited via memory clinics. Controls (N = 1625) were recruited via their general practitioners. All patients and controls were aged 55 years and older and of six different self-defined ethnicities (Dutch, Turkish, Moroccan-Arabic, Moroccan-Berber, Surinamese-Creole, and Surinamese-Hindustani). Exclusion criteria included current or previous conditions that affect cognitive functioning. There were performance differences between the ethnic groups, but these disappeared after correcting for age and education differences between the groups, which supports our central hypothesis that the CCD is a culture-fair test. Receiver-operating characteristic (ROC) and logistic regression analyses showed that the CCD has high predictive validity for dementia (sensitivity: 85%; specificity: 89%). The CCD is a sensitive and culture-fair neuropsychological instrument for dementia screening in low-educated immigrant populations.
Nano-JASMINE: cosmic radiation degradation of CCD performance and centroid detection
NASA Astrophysics Data System (ADS)
Kobayashi, Yukiyasu; Shimura, Yuki; Niwa, Yoshito; Yano, Taihei; Gouda, Naoteru; Yamada, Yoshiyuki
2012-09-01
Nano-JASMINE (NJ) is a very small astrometry satellite project led by the National Astronomical Observatory of Japan. The satellite is ready for launch, and the launch is currently scheduled for late 2013 or early 2014. The satellite is equipped with a fully depleted CCD and is expected to perform astrometry observations for stars brighter than 9 mag in the zw-band (0.6 µm-1.0 µm). Distances of stars located within 100 pc of the Sun can be determined by using annual parallax measurements. The targeted accuracy for the position determination of stars brighter than 7.5 mag is 3 mas, which is equivalent to measuring the positions of stars with an accuracy of less than one five-hundredth of the CCD pixel size. The position measurements of stars are performed by centroiding the stellar images taken by the CCD that operates in the time and delay integration mode. The degradation of charge transfer performance due to cosmic radiation damage in orbit is proved experimentally. A method is then required to compensate for the effects of performance degradation. One of the most effective ways of achieving this is to simulate observed stellar outputs, including the effect of CCD degradation, and then formulate our centroiding algorithm and evaluate the accuracies of the measurements. We report here the planned procedure to simulate the outputs of the NJ observations. We also developed a CCD performance-measuring system and present preliminary results obtained using the system.
One of the objectives of the National Human Exposure Assessment Survey (NHEXAS) is to estimate exposures to several pollutants in multiple media and determine their distributions for the population of Arizona. This paper presents modeling methods used to estimate exposure dist...
Boone, M.D.; Bridges, C.M.
2003-01-01
The majority of studies on pesticide impacts have evaluated the effects of single exposures. However, multiple exposures to a pesticide may be more prevalent. The objective of our study was to determine how multiple exposures versus single exposure at different times during development affected survival to metamorphosis, tadpole survival, tadpole mass, and tadpole developmental stage of green frog (Rana clamitans) tadpoles reared at low and high density in outdoor cattle tank ponds. Tadpoles were exposed to carbaryl zero, one, two, or three times at 14-d intervals. We applied single doses of carbaryl at one of three times, specifically during early, mid, or late development. Overall, we found that multiple exposures had a greater impact than single exposures during development. More individuals reached metamorphosis in ponds exposed to multiple doses of carbaryl compared with controls, indicating that the presence of carbaryl stimulated metamorphosis. The presence of carbaryl in the aquatic environment also resulted in more developed tadpoles compared with controls. Tadpoles in control ponds did not reach metamorphosis and were less developed than individuals exposed to carbaryl; this effect indicates that, under ideal conditions, green frogs could overwinter in ponds so that greater size could be attained before metamorphosis in the following spring or summer. Our study demonstrated the importance of including realistic application procedures when evaluating the effects of a pesticide and that multiple exposures to a short-lived pesticide are more likely to affect an amphibian population.
Two-dimensional singlet oxygen imaging with its near-infrared luminescence during photosensitization
Hu, Bolin; Zeng, Nan; Liu, Zhiyi; Ji, Yanhong; Xie, Weidong; Peng, Qing; Zhou, Yong; He, Yonghong; Ma, Hui
2011-01-01
Photodynamic therapy is a promising cancer treatment that involves activation of photosensitizer by visible light to create singlet oxygen. This highly reactive oxygen species is believed to induce cell death and tissue destruction in PDT. Our approach used a near-infrared area CCD with high quantum efficiency to detect singlet oxygen by its 1270-nm luminescence. Two-dimensional singlet oxygen images with its near-infrared luminescence during photosensitization could be obtained with a CCD integration time of 1 s, without scanning. Thus this system can produce singlet oxygen luminescence images faster and achieve more accurate measurements in comparison to raster-scanning methods. The experimental data show a linear relationship between the singlet oxygen luminescence intensity and sample concentration. This method provides a detection sensitivity of 0.0181 μg/ml (benzoporphyrin derivative monoacid ring A dissolved in ethanol) and a spatial resolution better than 50 μm. A pilot study was conducted on a total of six female Kunming mice. The results from this study demonstrate the system's potential for in vivo measurements. Further experiments were carried out on two tumor-bearing nude mice. Singlet oxygen luminescence images were acquired from the tumor-bearing nude mouse with intravenous injection of BPD-MA, and the experimental results showed real-time singlet oxygen signal depletion as a function of the light exposure. PMID:21280909
Malinauskas, Karolis; Palevicius, Paulius; Ragulskis, Minvydas; Ostasevicius, Vytautas; Dauksevicius, Rolanas
2013-01-01
Examination of wrist radial pulse is a noninvasive diagnostic method, which occupies a very important position in Traditional Chinese Medicine. It is based on manual palpation and therefore relies largely on the practitioner′s subjective technical skills and judgment. Consequently, it lacks reliability and consistency, which limits practical applications in clinical medicine. Thus, quantifiable characterization of the wrist pulse diagnosis method is a prerequisite for its further development and widespread use. This paper reports application of a noninvasive CCD sensor-based hybrid measurement system for radial pulse signal analysis. First, artery wall deformations caused by the blood flow are calibrated with a laser triangulation displacement sensor, following by the measurement of the deformations with projection moiré method. Different input pressures and fluids of various viscosities are used in the assembled artificial blood flow system in order to test the performance of laser triangulation technique with detection sensitivity enhancement through microfabricated retroreflective optical element placed on a synthetic vascular graft. Subsequently, the applicability of double-exposure whole-field projection moiré technique for registration of blood flow pulses is considered: a computational model and representative example are provided, followed by in vitro experiment performed on a vascular graft with artificial skin atop, which validates the suitability of the technique for characterization of skin surface deformations caused by the radial pulsation. PMID:23609803
Malinauskas, Karolis; Palevicius, Paulius; Ragulskis, Minvydas; Ostasevicius, Vytautas; Dauksevicius, Rolanas
2013-04-22
Examination of wrist radial pulse is a noninvasive diagnostic method, which occupies a very important position in Traditional Chinese Medicine. It is based on manual palpation and therefore relies largely on the practitioner's subjective technical skills and judgment. Consequently, it lacks reliability and consistency, which limits practical applications in clinical medicine. Thus, quantifiable characterization of the wrist pulse diagnosis method is a prerequisite for its further development and widespread use. This paper reports application of a noninvasive CCD sensor-based hybrid measurement system for radial pulse signal analysis. First, artery wall deformations caused by the blood flow are calibrated with a laser triangulation displacement sensor, following by the measurement of the deformations with projection moiré method. Different input pressures and fluids of various viscosities are used in the assembled artificial blood flow system in order to test the performance of laser triangulation technique with detection sensitivity enhancement through microfabricated retroreflective optical element placed on a synthetic vascular graft. Subsequently, the applicability of double-exposure whole-field projection moiré technique for registration of blood flow pulses is considered: a computational model and representative example are provided, followed by in vitro experiment performed on a vascular graft with artificial skin atop, which validates the suitability of the technique for characterization of skin surface deformations caused by the radial pulsation.
Overview of the Multi-Spectral Imager on the NEAR spacecraft
NASA Astrophysics Data System (ADS)
Hawkins, S. E., III
1996-07-01
The Multi-Spectral Imager on the Near Earth Asteroid Rendezvous (NEAR) spacecraft is a 1 Hz frame rate CCD camera sensitive in the visible and near infrared bands (~400-1100 nm). MSI is the primary instrument on the spacecraft to determine morphology and composition of the surface of asteroid 433 Eros. In addition, the camera will be used to assist in navigation to the asteroid. The instrument uses refractive optics and has an eight position spectral filter wheel to select different wavelength bands. The MSI optical focal length of 168 mm gives a 2.9 ° × 2.25 ° field of view. The CCD is passively cooled and the 537×244 pixel array output is digitized to 12 bits. Electronic shuttering increases the effective dynamic range of the instrument by more than a factor of 100. A one-time deployable cover protects the instrument during ground testing operations and launch. A reduced aperture viewport permits full field of view imaging while the cover is in place. A Data Processing Unit (DPU) provides the digital interface between the spacecraft and the Camera Head and uses an RTX2010 processor. The DPU provides an eight frame image buffer, lossy and lossless data compression routines, and automatic exposure control. An overview of the instrument is presented and design parameters and trade-offs are discussed.
Westbrook, John D; Shao, Chenghua; Feng, Zukang; Zhuravleva, Marina; Velankar, Sameer; Young, Jasmine
2015-04-15
The Chemical Component Dictionary (CCD) is a chemical reference data resource that describes all residue and small molecule components found in Protein Data Bank (PDB) entries. The CCD contains detailed chemical descriptions for standard and modified amino acids/nucleotides, small molecule ligands and solvent molecules. Each chemical definition includes descriptions of chemical properties such as stereochemical assignments, chemical descriptors, systematic chemical names and idealized coordinates. The content, preparation, validation and distribution of this CCD chemical reference dataset are described. The CCD is updated regularly in conjunction with the scheduled weekly release of new PDB structure data. The CCD and amino acid variant reference datasets are hosted in the public PDB ftp repository at ftp://ftp.wwpdb.org/pub/pdb/data/monomers/components.cif.gz, ftp://ftp.wwpdb.org/pub/pdb/data/monomers/aa-variants-v1.cif.gz, and its mirror sites, and can be accessed from http://wwpdb.org. jwest@rcsb.rutgers.edu. Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
GPS-CCD: A Novel Computational Program for the Prediction of Calpain Cleavage Sites
Gao, Xinjiao; Ma, Qian; Ren, Jian; Xue, Yu
2011-01-01
As one of the most essential post-translational modifications (PTMs) of proteins, proteolysis, especially calpain-mediated cleavage, plays an important role in many biological processes, including cell death/apoptosis, cytoskeletal remodeling, and the cell cycle. Experimental identification of calpain targets with bona fide cleavage sites is fundamental for dissecting the molecular mechanisms and biological roles of calpain cleavage. In contrast to time-consuming and labor-intensive experimental approaches, computational prediction of calpain cleavage sites might more cheaply and readily provide useful information for further experimental investigation. In this work, we constructed a novel software package of GPS-CCD (Calpain Cleavage Detector) for the prediction of calpain cleavage sites, with an accuracy of 89.98%, sensitivity of 60.87% and specificity of 90.07%. With this software, we annotated potential calpain cleavage sites for hundreds of calpain substrates, for which the exact cleavage sites had not been previously determined. In this regard, GPS-CCD 1.0 is considered to be a useful tool for experimentalists. The online service and local packages of GPS-CCD 1.0 were implemented in JAVA and are freely available at: http://ccd.biocuckoo.org/. PMID:21533053
3D morphology reconstruction using linear array CCD binocular stereo vision imaging system
NASA Astrophysics Data System (ADS)
Pan, Yu; Wang, Jinjiang
2018-01-01
Binocular vision imaging system, which has a small field of view, cannot reconstruct the 3-D shape of the dynamic object. We found a linear array CCD binocular vision imaging system, which uses different calibration and reconstruct methods. On the basis of the binocular vision imaging system, the linear array CCD binocular vision imaging systems which has a wider field of view can reconstruct the 3-D morphology of objects in continuous motion, and the results are accurate. This research mainly introduces the composition and principle of linear array CCD binocular vision imaging system, including the calibration, capture, matching and reconstruction of the imaging system. The system consists of two linear array cameras which were placed in special arrangements and a horizontal moving platform that can pick up objects. The internal and external parameters of the camera are obtained by calibrating in advance. And then using the camera to capture images of moving objects, the results are then matched and 3-D reconstructed. The linear array CCD binocular vision imaging systems can accurately measure the 3-D appearance of moving objects, this essay is of great significance to measure the 3-D morphology of moving objects.
Designing payment for Collaborative Care for Depression in primary care.
Bao, Yuhua; Casalino, Lawrence P; Ettner, Susan L; Bruce, Martha L; Solberg, Leif I; Unützer, Jürgen
2011-10-01
To design a bundled case rate for Collaborative Care for Depression (CCD) that aligns incentives with evidence-based depression care in primary care. A clinical information system used by all care managers in a randomized controlled trial of CCD for older primary care patients. We conducted an empirical investigation of factors accounting for variation in CCD resource use over time and across patients. CCD resource use at the patient-episode and patient-month levels was measured by number of care manager contacts and direct patient contact time and analyzed with count data (Poisson or negative binomial) models. Episode-level resource use varies substantially with patient's time in the program. Monthly use declines sharply in the first 6 months regardless of treatment response or remission status, but it remains stable afterwards. An adjusted episode or monthly case rate design better matches payment with variation in resource use compared with a fixed design. Our findings lend support to an episode payment adjusted by number of months receiving CCD and a monthly payment adjusted by the ordinal month. Nonpayment tools including program certification and performance evaluation and reward systems are needed to fully align incentives. © Health Research and Educational Trust.
Research of optical coherence tomography microscope based on CCD detector
NASA Astrophysics Data System (ADS)
Zhang, Hua; Xu, Zhongbao; Zhang, Shuomo
2008-12-01
The reference wave phase was modulated with a sinusoidal vibrating mirror attached to a Piezoelectric Transducer (PZT), the integration was performed by a CCD, and the charge storage period of the CCD image sensor was one-quarter period of the sinusoidal phase modulation. With the frequency- synchronous detection technique, four images (four frames of interference pattern) were recorded during one period of the phase modulation. In order to obtain the optimum modulation parameter, the values of amplitude and phase of the sinusoidal phase modulation were determined by considering the measurement error caused by the additive noise contained in the detected values. The PZT oscillation was controlled by a closed loop control system based on PID controller. An ideal discrete digital sine function at 50Hz with adjustable amplitude was used to adjust the vibrating of PZT, and a digital phase shift techniques was used to adjust vibrating phase of PZT so that the phase of the modulation could reach their optimum values. The CCD detector was triggered with software at 200Hz. Based on work above a small coherent signal masked by the preponderant incoherent background with a CCD detector was obtained.
Human exposure to xenobiotics may occur through multiple pathways and routes of entry punctuated by exposure intervals throughout a work or leisure day. Exposure to a single environmental chemical along multiple pathways and routes (aggregate exposure) may have an influence on an...
Institute CCD School Videos Student Projects Two Eyes, 3D Variable Star Astronomy H-R Diagram Plotting CHOICE Online Institute CCD School Videos Student Projects Two Eyes, 3D Variable Star Astronomy H-R
Evaluation of large format electron bombarded virtual phase CCDs as ultraviolet imaging detectors
NASA Technical Reports Server (NTRS)
Opal, Chet B.; Carruthers, George R.
1989-01-01
In conjunction with an external UV-sensitive cathode, an electron-bombarded CCD may be used as a high quantum efficiency/wide dynamic range photon-counting UV detector. Results are presented for the case of a 1024 x 1024, 18-micron square pixel virtual phase CCD used with an electromagnetically focused f/2 Schmidt camera, which yields excellent simgle-photoevent discrimination and counting efficiency. Attention is given to the vacuum-chamber arrangement used to conduct system tests and the CCD electronics and data-acquisition systems employed.
Optical synthesizer for a large quadrant-array CCD camera: Center director's discretionary fund
NASA Technical Reports Server (NTRS)
Hagyard, Mona J.
1992-01-01
The objective of this program was to design and develop an optical device, an optical synthesizer, that focuses four contiguous quadrants of a solar image on four spatially separated CCD arrays that are part of a unique CCD camera system. This camera and the optical synthesizer will be part of the new NASA-Marshall Experimental Vector Magnetograph, and instrument developed to measure the Sun's magnetic field as accurately as present technology allows. The tasks undertaken in the program are outlined and the final detailed optical design is presented.
InSb arrays with CCD readout for 1.0- to 5.5-microns infrared applications
NASA Technical Reports Server (NTRS)
Phillips, J. D.; Scorso, J. B.; Thom, R. D.
1976-01-01
There were two approaches for fabricating indium antimonide (InSb) arrays with CCD readout discussed. The hybrid approach integrated InSb detectors and silicon CCDs in a modular assembly via an advanced interconnection technology. In the monolithic approach, the InSb infrared detectors and the CCD readout were integrated on the same InSb chip. Both approaches utilized intrinsic (band-to-band) photodetection with the attendant advantages over extrinsic detectors. The status of each of these detector readout concepts, with pertinent performance characteristics, was presented.
A design of driving circuit for star sensor imaging camera
NASA Astrophysics Data System (ADS)
Li, Da-wei; Yang, Xiao-xu; Han, Jun-feng; Liu, Zhao-hui
2016-01-01
The star sensor is a high-precision attitude sensitive measuring instruments, which determine spacecraft attitude by detecting different positions on the celestial sphere. Imaging camera is an important portion of star sensor. The purpose of this study is to design a driving circuit based on Kodak CCD sensor. The design of driving circuit based on Kodak KAI-04022 is discussed, and the timing of this CCD sensor is analyzed. By the driving circuit testing laboratory and imaging experiments, it is found that the driving circuits can meet the requirements of Kodak CCD sensor.
Gombár, Melinda; Józsa, Éva; Braun, Mihály; Ősz, Katalin
2012-10-01
An inexpensive photoreactor using LED light sources and a fibre-optic CCD spectrophotometer as a detector was built by designing a special cell holder for standard 1.000 cm cuvettes. The use of this device was demonstrated by studying the aqueous photochemical reaction of 2,5-dichloro-1,4-benzoquinone. The developed method combines the highly quantitative data collection of CCD spectrophotometers with the possibility of illuminating the sample independently of the detecting light beam, which is a substantial improvement of the method using diode array spectrophotometers as photoreactors.
NEUTRON RADIATION DAMAGE IN CCD CAMERAS AT JOINT EUROPEAN TORUS (JET).
Milocco, Alberto; Conroy, Sean; Popovichev, Sergey; Sergienko, Gennady; Huber, Alexander
2017-10-26
The neutron and gamma radiations in large fusion reactors are responsible for damage to charged couple device (CCD) cameras deployed for applied diagnostics. Based on the ASTM guide E722-09, the 'equivalent 1 MeV neutron fluence in silicon' was calculated for a set of CCD cameras at the Joint European Torus. Such evaluations would be useful to good practice in the operation of the video systems. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
LAMOST CCD camera-control system based on RTS2
NASA Astrophysics Data System (ADS)
Tian, Yuan; Wang, Zheng; Li, Jian; Cao, Zi-Huang; Dai, Wei; Wei, Shou-Lin; Zhao, Yong-Heng
2018-05-01
The Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) is the largest existing spectroscopic survey telescope, having 32 scientific charge-coupled-device (CCD) cameras for acquiring spectra. Stability and automation of the camera-control software are essential, but cannot be provided by the existing system. The Remote Telescope System 2nd Version (RTS2) is an open-source and automatic observatory-control system. However, all previous RTS2 applications were developed for small telescopes. This paper focuses on implementation of an RTS2-based camera-control system for the 32 CCDs of LAMOST. A virtual camera module inherited from the RTS2 camera module is built as a device component working on the RTS2 framework. To improve the controllability and robustness, a virtualized layer is designed using the master-slave software paradigm, and the virtual camera module is mapped to the 32 real cameras of LAMOST. The new system is deployed in the actual environment and experimentally tested. Finally, multiple observations are conducted using this new RTS2-framework-based control system. The new camera-control system is found to satisfy the requirements for automatic camera control in LAMOST. This is the first time that RTS2 has been applied to a large telescope, and provides a referential solution for full RTS2 introduction to the LAMOST observatory control system.
Multiple Sensor Camera for Enhanced Video Capturing
NASA Astrophysics Data System (ADS)
Nagahara, Hajime; Kanki, Yoshinori; Iwai, Yoshio; Yachida, Masahiko
A resolution of camera has been drastically improved under a current request for high-quality digital images. For example, digital still camera has several mega pixels. Although a video camera has the higher frame-rate, the resolution of a video camera is lower than that of still camera. Thus, the high-resolution is incompatible with the high frame rate of ordinary cameras in market. It is difficult to solve this problem by a single sensor, since it comes from physical limitation of the pixel transfer rate. In this paper, we propose a multi-sensor camera for capturing a resolution and frame-rate enhanced video. Common multi-CCDs camera, such as 3CCD color camera, has same CCD for capturing different spectral information. Our approach is to use different spatio-temporal resolution sensors in a single camera cabinet for capturing higher resolution and frame-rate information separately. We build a prototype camera which can capture high-resolution (2588×1958 pixels, 3.75 fps) and high frame-rate (500×500, 90 fps) videos. We also proposed the calibration method for the camera. As one of the application of the camera, we demonstrate an enhanced video (2128×1952 pixels, 90 fps) generated from the captured videos for showing the utility of the camera.
CCD imaging technology and the war on crime
NASA Astrophysics Data System (ADS)
McNeill, Glenn E.
1992-08-01
Linear array based CCD technology has been successfully used in the development of an Automatic Currency Reader/Comparator (ACR/C) system. The ACR/C system is designed to provide a method for tracking US currency in the organized crime and drug trafficking environments where large amounts of cash are involved in illegal transactions and money laundering activities. United States currency notes can be uniquely identified by the combination of the denomination serial number and series year. The ACR/C system processes notes at five notes per second using a custom transport a stationary linear array and optical character recognition (OCR) techniques to make such identifications. In this way large sums of money can be " marked" (using the system to read and store their identifiers) and then circulated within various crime networks. The system can later be used to read and compare confiscated notes to the known sets of identifiers from the " marked" set to document a trail of criminal activities. With the ACR/C law enforcement agencies can efficiently identify currency without actually marking it. This provides an undetectable means for making each note individually traceable and facilitates record keeping for providing evidence in a court of law. In addition when multiple systems are used in conjunction with a central data base the system can be used to track currency geographically. 1.
Development and performances of very long stripe-filters for a multispectral detector
NASA Astrophysics Data System (ADS)
Laubier, David; Gimenez, Thierry; Mercier-Ythier, Renaud
2002-01-01
The development in the past few years of all-mirror telescopes has opened a wide new range of possibilities to instrument designers, with features like high compactness and outstanding optical quality over wide fields of view. However, this design imposes specific constraints on the focal plane: it can no longer accommodate glass beamsplitters and its size increases with the field of view. New CCD detectors with multiple long lines are well-suited to this application, but require a new filters strategy. This paper will detail what ours was in the particular case of a 78-mm long, 4-channel CCD. The choice of the stripe- filters concept was made on the basis of a performance versus cost analysis. Two kinds of assemblies were retained at this stage. The components manufactured by SAGEM-REOSC PRODUCTS in an initial development phase showed good spectral performance with high rejection over a very wide range of wavelengths. Some topics like local defects and straylight needed specific work. The paper focuses on the impact of the defects on the performances and the way they have been dealt with, and on the straylight design strategy with the results obtained in the different cases. In particular, it shows how the detector's design can be partially driven by the straylight requirements.
Reduction of time-resolved space-based CCD photometry developed for MOST Fabry Imaging data*
NASA Astrophysics Data System (ADS)
Reegen, P.; Kallinger, T.; Frast, D.; Gruberbauer, M.; Huber, D.; Matthews, J. M.; Punz, D.; Schraml, S.; Weiss, W. W.; Kuschnig, R.; Moffat, A. F. J.; Walker, G. A. H.; Guenther, D. B.; Rucinski, S. M.; Sasselov, D.
2006-04-01
The MOST (Microvariability and Oscillations of Stars) satellite obtains ultraprecise photometry from space with high sampling rates and duty cycles. Astronomical photometry or imaging missions in low Earth orbits, like MOST, are especially sensitive to scattered light from Earthshine, and all these missions have a common need to extract target information from voluminous data cubes. They consist of upwards of hundreds of thousands of two-dimensional CCD frames (or subrasters) containing from hundreds to millions of pixels each, where the target information, superposed on background and instrumental effects, is contained only in a subset of pixels (Fabry Images, defocused images, mini-spectra). We describe a novel reduction technique for such data cubes: resolving linear correlations of target and background pixel intensities. This step-wise multiple linear regression removes only those target variations which are also detected in the background. The advantage of regression analysis versus background subtraction is the appropriate scaling, taking into account that the amount of contamination may differ from pixel to pixel. The multivariate solution for all pairs of target/background pixels is minimally invasive of the raw photometry while being very effective in reducing contamination due to, e.g. stray light. The technique is tested and demonstrated with both simulated oscillation signals and real MOST photometry.
An exposure indicator for digital radiography: AAPM Task Group 116 (executive summary).
Shepard, S Jeff; Wang, Jihong; Flynn, Michael; Gingold, Eric; Goldman, Lee; Krugh, Kerry; Leong, David L; Mah, Eugene; Ogden, Kent; Peck, Donald; Samei, Ehsan; Wang, Jihong; Willis, Charles E
2009-07-01
Digital radiographic imaging systems, such as those using photostimulable storage phosphor, amorphous selenium, amorphous silicon, CCD, and MOSFET technology, can produce adequate image quality over a much broader range of exposure levels than that of screen/film imaging systems. In screen/film imaging, the final image brightness and contrast are indicative of over- and underexposure. In digital imaging, brightness and contrast are often determined entirely by digital postprocessing of the acquired image data. Overexposure and underexposures are not readily recognizable. As a result, patient dose has a tendency to gradually increase over time after a department converts from screen/film-based imaging to digital radiographic imaging. The purpose of this report is to recommend a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The intent is to facilitate the production of consistent, high quality digital radiographic images at acceptable patient doses. This should be based not on image optical density or brightness but on feedback regarding the detector exposure provided and actively monitored by the imaging system. A standard beam calibration condition is recommended that is based on RQA5 but uses filtration materials that are commonly available and simple to use. Recommendations on clinical implementation of the indices to control image quality and patient dose are derived from historical tolerance limits and presented as guidelines.
An exposure indicator for digital radiography: AAPM Task Group 116 (Executive Summary)
Shepard, S. Jeff; Wang, Jihong; Flynn, Michael; Gingold, Eric; Goldman, Lee; Krugh, Kerry; Leong, David L.; Mah, Eugene; Ogden, Kent; Peck, Donald; Samei, Ehsan; Wang, Jihong; Willis, Charles E.
2009-01-01
Digital radiographic imaging systems, such as those using photostimulable storage phosphor, amorphous selenium, amorphous silicon, CCD, and MOSFET technology, can produce adequate image quality over a much broader range of exposure levels than that of screen/film imaging systems. In screen/film imaging, the final image brightness and contrast are indicative of over- and underexposure. In digital imaging, brightness and contrast are often determined entirely by digital postprocessing of the acquired image data. Overexposure and underexposures are not readily recognizable. As a result, patient dose has a tendency to gradually increase over time after a department converts from screen/film-based imaging to digital radiographic imaging. The purpose of this report is to recommend a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The intent is to facilitate the production of consistent, high quality digital radiographic images at acceptable patient doses. This should be based not on image optical density or brightness but on feedback regarding the detector exposure provided and actively monitored by the imaging system. A standard beam calibration condition is recommended that is based on RQA5 but uses filtration materials that are commonly available and simple to use. Recommendations on clinical implementation of the indices to control image quality and patient dose are derived from historical tolerance limits and presented as guidelines. PMID:19673189
Olatunji, Bunmi O; Tomarken, Andrew; Wentworth, Brian; Fritzsche, Laura
2017-03-01
The current study examines effects of exposure in multiple contexts on fear reduction and renewal and the moderating effect of baseline threat-specific and nonspecific emotionality. Snake-fearful participants received a negative or neutral emotion induction and were randomized to video exposure to a snake in a single context, multiple context, or a no exposure control group. Anxiety in response to video presentations of a snake was significantly reduced in the two exposure groups compared to the control group, especially among those with heightened baseline threat-specific emotionality as indicated by snake anxiety ratings at baseline. Although the two exposure groups did not differ in responding when confronted with a novel snake, both exposure groups reported significantly lower snake anxiety and arousal than the control group. Subsequent analysis did show that compared to controls, the single context group demonstrated greater increase in anxiety and arousal from post-exposure to exposure to the novel snake among those with heightened snake anxiety at baseline. Furthermore, the multiple context group was less avoidant and less fearful than the single context group on a post-exposure behavioral test. The study used an analogue exposure paradigm with an analogue sample and findings may not be generalizable to a clinical population. These findings suggest that baseline threat-specific emotionality influences fear reduction and renewal. The benefits of exposure in multiple contexts are discussed in relation to a distinct pattern of symptom change that is in line with an inhibitory learning approach. Copyright © 2016 Elsevier Ltd. All rights reserved.
A method of immediate detection of objects with a near-zero apparent motion in series of CCD-frames
NASA Astrophysics Data System (ADS)
Savanevych, V. E.; Khlamov, S. V.; Vavilova, I. B.; Briukhovetskyi, A. B.; Pohorelov, A. V.; Mkrtichian, D. E.; Kudak, V. I.; Pakuliak, L. K.; Dikov, E. N.; Melnik, R. G.; Vlasenko, V. P.; Reichart, D. E.
2018-01-01
The paper deals with a computational method for detection of the solar system minor bodies (SSOs), whose inter-frame shifts in series of CCD-frames during the observation are commensurate with the errors in measuring their positions. These objects have velocities of apparent motion between CCD-frames not exceeding three rms errors (3σ) of measurements of their positions. About 15% of objects have a near-zero apparent motion in CCD-frames, including the objects beyond the Jupiter's orbit as well as the asteroids heading straight to the Earth. The proposed method for detection of the object's near-zero apparent motion in series of CCD-frames is based on the Fisher f-criterion instead of using the traditional decision rules that are based on the maximum likelihood criterion. We analyzed the quality indicators of detection of the object's near-zero apparent motion applying statistical and in situ modeling techniques in terms of the conditional probability of the true detection of objects with a near-zero apparent motion. The efficiency of method being implemented as a plugin for the Collection Light Technology (CoLiTec) software for automated asteroids and comets detection has been demonstrated. Among the objects discovered with this plugin, there was the sungrazing comet C/2012 S1 (ISON). Within 26 min of the observation, the comet's image has been moved by three pixels in a series of four CCD-frames (the velocity of its apparent motion at the moment of discovery was equal to 0.8 pixels per CCD-frame; the image size on the frame was about five pixels). Next verification in observations of asteroids with a near-zero apparent motion conducted with small telescopes has confirmed an efficiency of the method even in bad conditions (strong backlight from the full Moon). So, we recommend applying the proposed method for series of observations with four or more frames.
Beumer, Wouter; Welzen-Coppens, Jojanneke M. C.; van Helden-Meeuwsen, Cornelia G.; Gibney, Sinead M.; Drexhage, Hemmo A.; Versnel, Marjan A.
2014-01-01
Two major dendritic cell (DC) subsets have been described in the pancreas of mice: The CD11c+CD8α− DCs (strong CD4+ T cell proliferation inducers) and the CD8α+CD103+ DCs (T cell apoptosis inducers). Here we analyzed the larger subset of CD11c+CD8α− DCs isolated from the pancreas of pre-diabetic NOD mice for genome-wide gene expression (validated by Q-PCR) to elucidate abnormalities in underlying gene expression networks. CD11c+CD8α− DCs were isolated from 5 week old NOD and control C57BL/6 pancreas. The steady state pancreatic NOD CD11c+CD8α− DCs showed a reduced expression of several gene networks important for the prime functions of these cells, i.e. for cell renewal, immune tolerance induction, migration and for the provision of growth factors including those for beta cell regeneration. A functional in vivo BrdU incorporation test showed the reduced proliferation of steady state pancreatic DC. The reduced expression of tolerance induction genes (CD200R, CCR5 and CD24) was supported on the protein level by flow cytometry. Also previously published functional tests on maturation, immune stimulation and migration confirm the molecular deficits of NOD steady state DC. Despite these deficiencies NOD pancreas CD11c+CD8α− DCs showed a hyperreactivity to LPS, which resulted in an enhanced pro-inflammatory state characterized by a gene profile of an enhanced expression of a number of classical inflammatory cytokines. The enhanced up-regulation of inflammatory genes was supported by the in vitro cytokine production profile of the DCs. In conclusion, our data show that NOD pancreatic CD11c+CD8α− DCs show various deficiencies in steady state, while hyperreactive when encountering a danger signal such as LPS. PMID:25166904
Application of the CCD Fabry-Perot Annular Summing Technique to Thermospheric O(1)D.
NASA Astrophysics Data System (ADS)
Coakley, Monica Marie
1995-01-01
This work will detail the verification of the advantages of the Fabry-Perot charge coupled device (CCD) annular summing technique, the development of the technique for analysis of daysky spectra, and the implications of the resulting spectra for neutral temperature and wind measurements in the daysky thermosphere. The daysky spectral feature of interest is the bright (1 kilo-Rayleigh) thermospheric (OI) emission at 6300 A which had been observed in the nightsky in order to determine winds and temperatures in the vicinity of the altitude of 250 km. In the daysky, the emission line sits on top of a bright Rayleigh scattered continuum background which significantly complicates the observation. With a triple etalon Fabry-Perot spectrometer, the continuum background can be reduced while maintaining high throughput and high resolution. The inclusion of a CCD camera results in significant savings in integration time over the two more standard scanning photomultiplier systems that have made the same wind and temperature measurements in the past. A comparable CCD system can experience an order of magnitude savings in integration time over a PMT system. Laboratory and field tests which address the advantages and limitations of both the Fabry-Perot CCD annular summing technique and the daysky CCD imaging are included in Chap. 2 and Chap. 3. With a sufficiently large throughput associated with the spectrometer and a CCD detector, rapid observations (~4 minute integrations) can be made. Extraction of the line width and line center from the daysky near-continuum background is complicated compared to the nightsky case, but possible. Methods of fitting the line are included in Chap. 4. The daysky O ^1D temperatures are consistent with a lower average emission height than predicted by models. The data and models are discussed in Chap. 5. Although some discrepancies exist between resulting temperatures and models, the observations indicate the potential for other direct measurements of bright neutral species in the daysky as well as the potential for twenty-four hour coverage.
Flat Field Anomalies in an X-ray CCD Camera Measured Using a Manson X-ray Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
M. J. Haugh and M. B. Schneider
2008-10-31
The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. The intensity distribution taken by the SXI camera during a NIF shot is used to determine how accurately NIF can aim laser beams. This is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 μm square pixels, and 15 μm thick. Amore » multi-anode Manson X-ray source, operating up to 10kV and 10W, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE≈10. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within ±1% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation occurred at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was not observable below 4 keV. We were also able to observe debris, damage, and surface defects on the CCD chip. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager.« less
Multiple coherent light scattering in ultracold rubidium
NASA Astrophysics Data System (ADS)
Kulatunga, P.; Sukenik, C. I.; Havey, M. D.; Kupriyanov, D. V.; Sokolov, I. M.
2001-11-01
We report investigation of multiple coherent light scattering from ^85Rb atoms confined in a magneto-optic trap. In a theoretical study of intensity enhancement of near-resonant backscattered light from cold ^85,87Rb atoms, we consider the dominant mode of double scattering only. Enhancement factors are calculated for all D1 and D2 hyperfine components and for both isotopes. In experimental studies, measurements are made of coherent backscattering of a low-intensity probe beam tuned near the F = 3 - F' = 4 transition in ^85Rb atoms. Polarization of backscattered light is determined by a backscattering polarimeter; the spatial distribution of light intensity is measured by a liquid-nitrogen cooled CCD camera set in the focal plane of the analyzing optics. The instrument has angular resolution of about 100 micro-radians, and a polarization analyzing power of roughly 1000. In this paper we describe the instrument details, including calibration procedures, and progress towards observation of atomic coherent backscattering.
Multiple coherent light scattering in ultracold rubidium
NASA Astrophysics Data System (ADS)
Havey, M. D.; Sukenik, C. I.; Kulatunga, P.; Kupriyanov, D. V.; Sokolov, I. M.
2001-05-01
We report investigation of multiple coherent light scattering from ^85Rb atoms confined in a magneto-optic trap. In a theoretical study of intensity enhancement of near-resonant backscattered light from cold ^85,87Rb atoms, we consider the dominant mode of double scattering only. Enhancement factors are calculated for all D1 and D2 hyperfine components and for both isotopes. In experimental studies, measurements are made of coherent backscattering of a low-intensity probe beam tuned near the F = 3 - F' = 4 transition in ^85Rb atoms. Polarization of backscattered light is determined by a backscattering polarimeter; the spatial distribution of light intensity is measured by a liquid-nitrogen cooled CCD camera set in the focal plane of the analyzing optics. The instrument has angular resolution of about 100 micro-radians, and a polarization analyzing power of roughly 1000. In this paper we describe the instrument details, including calibration procedures, and progress towards observation of atomic coherent backscattering.
Very large ground-based telescopes for optical and IR astronomy
NASA Technical Reports Server (NTRS)
Angel, J. R. P.
1982-01-01
Methods for improving the light grasp by an order of magnitude for earth-based observations of astrophysical objects are reviewed. Noting that the atmosphere is opaque below 0.3 micron and that techniques have been developed to make corrections for the atmospheric distortion, fully diffraction limited IR performance at 10 microns is asserted to be practicable. The use of mirror-seeing with metal mirrors with thin faceplates and air cooling is outlined as a means to achieve subarcsec resolution. Designs are considered which involve multiple sections to gain effective large aperture viewing for spectroscopy, using Si CCD detectors, and heterodyne IR interferometry, but not for direct interferometry or certain IR measurements. The Multiple Mirror Telescope is described, including designs for four 7.5 m honeycomb glass primaries co-aligned in a single mount. Further discussion is devoted to the fabrication of mirror elements and electronic image stabilization.
CCD Times of Minima of Faint Eclipsing Binaries in 2000
NASA Astrophysics Data System (ADS)
Zejda, Miloslav
2002-06-01
196 CCD minima observations of 122 eclipsing binaries made by the author in 2000 are presented. The observed stars were chosen from the catalogue BRKA of observing programme of BRNO-Variable Star Section of CAS.
Active Pixel Sensors: Are CCD's Dinosaurs?
NASA Technical Reports Server (NTRS)
Fossum, Eric R.
1993-01-01
Charge-coupled devices (CCD's) are presently the technology of choice for most imaging applications. In the 23 years since their invention in 1970, they have evolved to a sophisticated level of performance. However, as with all technologies, we can be certain that they will be supplanted someday. In this paper, the Active Pixel Sensor (APS) technology is explored as a possible successor to the CCD. An active pixel is defined as a detector array technology that has at least one active transistor within the pixel unit cell. The APS eliminates the need for nearly perfect charge transfer -- the Achilles' heel of CCDs. This perfect charge transfer makes CCD's radiation 'soft,' difficult to use under low light conditions, difficult to manufacture in large array sizes, difficult to integrate with on-chip electronics, difficult to use at low temperatures, difficult to use at high frame rates, and difficult to manufacture in non-silicon materials that extend wavelength response.
Measurement of phase function of aerosol at different altitudes by CCD Lidar
NASA Astrophysics Data System (ADS)
Sun, Peiyu; Yuan, Ke'e.; Yang, Jie; Hu, Shunxing
2018-02-01
The aerosols near the ground are closely related to human health and climate change, the study on which has important significance. As we all know, the aerosol is inhomogeneous at different altitudes, of which the phase function is also different. In order to simplify the retrieval algorithm, it is usually assumed that the aerosol is uniform at different altitudes, which will bring measurement error. In this work, an experimental approach is demonstrated to measure the scattering phase function of atmospheric aerosol particles at different heights by CCD lidar system, which could solve the problem of the traditional CCD lidar system in assumption of phase function. The phase functions obtained by the new experimental approach are used to retrieve the aerosol extinction coefficient profiles. By comparison of the aerosol extinction coefficient retrieved by Mie-scattering aerosol lidar and CCD lidar at night, the reliability of new experimental approach is verified.
Direct detection of x-rays for protein crystallography employing a thick, large area CCD
Atac, Muzaffer; McKay, Timothy
1999-01-01
An apparatus and method for directly determining the crystalline structure of a protein crystal. The crystal is irradiated by a finely collimated x-ray beam. The interaction of the x-ray beam with the crystal produces scattered x-rays. These scattered x-rays are detected by means of a large area, thick CCD which is capable of measuring a significant number of scattered x-rays which impact its surface. The CCD is capable of detecting the position of impact of the scattered x-ray on the surface of the CCD and the quantity of scattered x-rays which impact the same cell or pixel. This data is then processed in real-time and the processed data is outputted to produce a image of the structure of the crystal. If this crystal is a protein the molecular structure of the protein can be determined from the data received.
NASA Astrophysics Data System (ADS)
Butner, Melissa Jean
The DaMIC (Dark Matter in CCDs) experiment searches for dark matter particles using charge coupled devices (CCDs) operated at a low detection threshold of ˜40 eV electron equivalent energy (eVee). A multiplexor board is tested for DAMIC100+ which has the ability to control up to 16 CCDs at one time allowing for the selection of a single CCD for readout while leaving all others static and maintaining sub-electron noise. A dark matter limit is produced using the results of physics data taken with the DAMIC experiment. Next, the contribution from neutrino-nucleus coherent scattering is investigated using data from the Coherent Neutrino Nucleus Interaction Experiment (CONnuIE) using the same CCD technology. The results are used to explore the performance of CCD detectors that ultimately will limit the ability to differentiate incident solar and atmospheric neutrinos from dark matter particles.
A wide bandwidth CCD buffer memory system
NASA Technical Reports Server (NTRS)
Siemens, K.; Wallace, R. W.; Robinson, C. R.
1978-01-01
A prototype system was implemented to demonstrate that CCD's can be applied advantageously to the problem of low power digital storage and particularly to the problem of interfacing widely varying data rates. CCD shift register memories (8K bit) were used to construct a feasibility model 128 K-bit buffer memory system. Serial data that can have rates between 150 kHz and 4.0 MHz can be stored in 4K-bit, randomly-accessible memory blocks. Peak power dissipation during a data transfer is less than 7 W, while idle power is approximately 5.4 W. The system features automatic data input synchronization with the recirculating CCD memory block start address. System expansion to accommodate parallel inputs or a greater number of memory blocks can be performed in a modular fashion. Since the control logic does not increase proportionally to increase in memory capacity, the power requirements per bit of storage can be reduced significantly in a larger system.
Nikcevic, Irena; Piruska, Aigars; Wehmeyer, Kenneth R; Seliskar, Carl J; Limbach, Patrick A; Heineman, William R
2010-08-01
Parallel separations using CE on a multilane microchip with multiplexed LIF detection is demonstrated. The detection system was developed to simultaneously record data on all channels using an expanded laser beam for excitation, a camera lens to capture emission, and a CCD camera for detection. The detection system enables monitoring of each channel continuously and distinguishing individual lanes without significant crosstalk between adjacent lanes. Multiple analytes can be determined in parallel lanes within a single microchip in a single run, leading to increased sample throughput. The pK(a) determination of small molecule analytes is demonstrated with the multilane microchip.
Nikcevic, Irena; Piruska, Aigars; Wehmeyer, Kenneth R.; Seliskar, Carl J.; Limbach, Patrick A.; Heineman, William R.
2010-01-01
Parallel separations using capillary electrophoresis on a multilane microchip with multiplexed laser induced fluorescence detection is demonstrated. The detection system was developed to simultaneously record data on all channels using an expanded laser beam for excitation, a camera lens to capture emission, and a CCD camera for detection. The detection system enables monitoring of each channel continuously and distinguishing individual lanes without significant crosstalk between adjacent lanes. Multiple analytes can be analyzed on parallel lanes within a single microchip in a single run, leading to increased sample throughput. The pKa determination of small molecule analytes is demonstrated with the multilane microchip. PMID:20737446
NASA Astrophysics Data System (ADS)
Johnson, Kristina Mary
In 1973 the computerized tomography (CT) scanner revolutionized medical imaging. This machine can isolate and display in two-dimensional cross-sections, internal lesions and organs previously impossible to visualize. The possibility of three-dimensional imaging however is not yet exploited by present tomographic systems. Using multiple-exposure holography, three-dimensional displays can be synthesizing from two-dimensional CT cross -sections. A multiple-exposure hologram is an incoherent superposition of many individual holograms. Intuitively it is expected that holograms recorded with equal energy will reconstruct images with equal brightness. It is found however, that holograms recorded first are brighter than holograms recorded later in the superposition. This phenomena is called Holographic Reciprocity Law Failure (HRLF). Computer simulations of latent image formation in multiple-exposure holography are one of the methods used to investigate HRLF. These simulations indicate that it is the time between individual exposures in the multiple -exposure hologram that is responsible for HRLF. This physical parameter introduces an asymmetry into the latent image formation process that favors the signal of previously recorded holograms over holograms recorded later in the superposition. The origin of this asymmetry lies in the dynamics of latent image formation, and in particular in the decay of single-atom latent image specks, which have lifetimes that are short compared to typical times between exposures. An analytical model is developed for a double exposure hologram that predicts a decrease in the brightness of the second exposure as compared to the first exposure as the time between exposures increases. These results are consistent with the computer simulations. Experiments investigating the influence of this parameter on the diffraction efficiency of reconstructed images in a double exposure hologram are also found to be consistent with the computer simulations and analytical results. From this information, two techniques are presented that correct for HRLF, and succeed in reconstructing multiple holographic images of CT cross-sections with equal brightness. The multiple multiple-exposure hologram is a new hologram that increases the number of equally bright images that can be superimposed on one photographic plate.
PN-CCD camera for XMM: performance of high time resolution/bright source operating modes
NASA Astrophysics Data System (ADS)
Kendziorra, Eckhard; Bihler, Edgar; Grubmiller, Willy; Kretschmar, Baerbel; Kuster, Markus; Pflueger, Bernhard; Staubert, Ruediger; Braeuninger, Heinrich W.; Briel, Ulrich G.; Meidinger, Norbert; Pfeffermann, Elmar; Reppin, Claus; Stoetter, Diana; Strueder, Lothar; Holl, Peter; Kemmer, Josef; Soltau, Heike; von Zanthier, Christoph
1997-10-01
The pn-CCD camera is developed as one of the focal plane instruments for the European photon imaging camera (EPIC) on board the x-ray multi mirror (XMM) mission to be launched in 1999. The detector consists of four quadrants of three pn-CCDs each, which are integrated on one silicon wafer. Each CCD has 200 by 64 pixels (150 micrometer by 150 micrometers) with 280 micrometers depletion depth. One CCD of a quadrant is read out at a time, while the four quadrants can be processed independently of each other. In standard imaging mode the CCDs are read out sequentially every 70 ms. Observations of point sources brighter than 1 mCrab will be effected by photon pile- up. However, special operating modes can be used to observe bright sources up to 150 mCrab in timing mode with 30 microseconds time resolution and very bright sources up to several crab in burst mode with 7 microseconds time resolution. We have tested one quadrant of the EPIC pn-CCD camera at line energies from 0.52 keV to 17.4 keV at the long beam test facility Panter in the focus of the qualification mirror module for XMM. In order to test the time resolution of the system, a mechanical chopper was used to periodically modulate the beam intensity. Pulse periods down to 0.7 ms were generated. This paper describes the performance of the pn-CCD detector in timing and burst readout modes with special emphasis on energy and time resolution.
NASA Astrophysics Data System (ADS)
Xue, Bo; Mao, Bingjing; Chen, Xiaomei; Ni, Guoqiang
2010-11-01
This paper renders a configurable distributed high performance computing(HPC) framework for TDI-CCD imaging simulation. It uses strategy pattern to adapt multi-algorithms. Thus, this framework help to decrease the simulation time with low expense. Imaging simulation for TDI-CCD mounted on satellite contains four processes: 1) atmosphere leads degradation, 2) optical system leads degradation, 3) electronic system of TDI-CCD leads degradation and re-sampling process, 4) data integration. Process 1) to 3) utilize diversity data-intensity algorithms such as FFT, convolution and LaGrange Interpol etc., which requires powerful CPU. Even uses Intel Xeon X5550 processor, regular series process method takes more than 30 hours for a simulation whose result image size is 1500 * 1462. With literature study, there isn't any mature distributing HPC framework in this field. Here we developed a distribute computing framework for TDI-CCD imaging simulation, which is based on WCF[1], uses Client/Server (C/S) layer and invokes the free CPU resources in LAN. The server pushes the process 1) to 3) tasks to those free computing capacity. Ultimately we rendered the HPC in low cost. In the computing experiment with 4 symmetric nodes and 1 server , this framework reduced about 74% simulation time. Adding more asymmetric nodes to the computing network, the time decreased namely. In conclusion, this framework could provide unlimited computation capacity in condition that the network and task management server are affordable. And this is the brand new HPC solution for TDI-CCD imaging simulation and similar applications.
Davila, Stephen J; Hadjar, Omar; Eiceman, Gary A
2013-07-16
A linear pixel-based detector array, the IonCCD, is characterized for use under ambient conditions with thermal (<1 eV) positive ions derived from purified air and a 10 mCi (63)Ni foil. The IonCCD combined with a drift tube-ion mobility spectrometer permitted the direct detection of gas phase ions at atmospheric pressure and confirmed a limit of detection of 3000 ions/pixel/frame established previously in both the keV (1-2 keV) and the hyper-thermal (10-40 eV) regimes. Results demonstrate the "broad-band" application of the IonCCD over 10(5) orders in ion energy and over 10(10) in operating pressure. The Faraday detector of a drift tube for an ion mobility spectrometer was replaced with the IonCCD providing images of ion profiles over the cross-section of the drift tube. Patterns in the ion profiles were developed in the drift tube cross-section by control of electric fields between wires of Bradbury Nielson and Tyndall Powell shutter designs at distances of 1-8 cm from the detector. Results showed that ion beams formed in wire sets, retained their shape with limited mixing by diffusion and Coulombic repulsion. Beam broadening determined as 95 μm/cm for hydrated protons in air with moisture of ~10 ppmv. These findings suggest a value of the IonCCD in further studies of ion motion and diffusion of thermalized ions, enhancing computational results from simulation programs, and in the design or operation of ion mobility spectrometers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glover, Karen; Li, Yue; Mukhopadhyay, Shreya
Beclin 1 (BECN1) is a key regulator of autophagy, a critical catabolic homeostasis pathway that involves sequestration of selected cytoplasmic components by multilayered vesicles called autophagosomes, followed by lysosomal fusion and degradation. BECN1 is a core component of class III phosphatidylinositol-3-kinase complexes responsible for autophagosome nucleation. Without heterologous binding partners, BECN1 forms an antiparallel homodimer via its coiled-coil domain (CCD). However, the last 16 CCD residues, composing an “overlap helix” (OH), have been crystallized in two mutually exclusive states: either as part of the CCD or packed against the C-terminal β-α repeated, autophagy-specific domain (BARAD). Here, using CD spectroscopy, isothermalmore » titration calorimetry, and small-angle X-ray scattering, we show that in the homodimeric state, the OH transitions between these two different packing states, with the predominant state comprising the OH packed against the BARAD, contrary to expectations based on known BECN1 interactions with heterologous partners. We confirmed this observation by comparing the impact of mutating four residues that mediate packing of the OH against both the CCD and BARAD on structure and stability of the CCD, the OH+BARAD, and the two-domain CCD–BARAD. Last, we used cellular assays to demonstrate that mutation of these OH-interface residues abrogates starvation-induced up-regulation of autophagy but does not affect basal autophagy. In summary, we have identified a BECN1 helical region that transitions between packing as part of either one of two conserved domains (i.e. the CCD or the BARAD). Our findings have important implications for the relative stability of autophagy-inactive and autophagy-active BECN1 complexes.« less
A New Serial-direction Trail Effect in CCD Images of the Lunar-based Ultraviolet Telescope
NASA Astrophysics Data System (ADS)
Wu, C.; Deng, J. S.; Guyonnet, A.; Antilogus, P.; Cao, L.; Cai, H. B.; Meng, X. M.; Han, X. H.; Qiu, Y. L.; Wang, J.; Wang, S.; Wei, J. Y.; Xin, L. P.; Li, G. W.
2016-10-01
Unexpected trails have been seen subsequent to relative bright sources in astronomical images taken with the CCD camera of the Lunar-based Ultraviolet Telescope (LUT) since its first light on the Moon’s surface. The trails can only be found in the serial-direction of CCD readout, differing themselves from image trails of radiation-damaged space-borne CCDs, which usually appear in the parallel-readout direction. After analyzing the same trail defects following warm pixels (WPs) in dark frames, we found that the relative intensity profile of the LUT CCD trails can be expressed as an exponential function of the distance i (in number of pixels) of the trailing pixel to the original source (or WP), i.e., {\\mathtt{\\exp }}(α {\\mathtt{i}}+β ). The parameters α and β seem to be independent of the CCD temperature, intensity of the source (or WP), and its position in the CCD frame. The main trail characteristics show evolution occurring at an increase rate of ˜(7.3 ± 3.6) × 10-4 in the first two operation years. The trails affect the consistency of the profiles of different brightness sources, which make smaller aperture photometry have larger extra systematic error. The astrometric uncertainty caused by the trails is too small to be acceptable based on LUT requirements for astrometry accuracy. Based on the empirical profile model, a correction method has been developed for LUT images that works well for restoring the fluxes of astronomical sources that are lost in trailing pixels.
NASA Technical Reports Server (NTRS)
1999-01-01
Jet Propulsion Laboratory's research on a second generation, solid-state image sensor technology has resulted in the Complementary Metal- Oxide Semiconductor Active Pixel Sensor (CMOS), establishing an alternative to the Charged Coupled Device (CCD). Photobit Corporation, the leading supplier of CMOS image sensors, has commercialized two products of their own based on this technology: the PB-100 and PB-300. These devices are cameras on a chip, combining all camera functions. CMOS "active-pixel" digital image sensors offer several advantages over CCDs, a technology used in video and still-camera applications for 30 years. The CMOS sensors draw less energy, they use the same manufacturing platform as most microprocessors and memory chips, and they allow on-chip programming of frame size, exposure, and other parameters.
Generation of large-area and glow-like surface discharge in atmospheric pressure air
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, Ying; Bi, Zhenhua; Wang, Xueyang
2016-08-15
A large-area (6 cm × 6 cm) air surface dielectric barrier discharge has been generated at atmospheric pressure by using well-aligned and micron-sized dielectric tubes with tungsten wire electrodes. Intensified CCD images with an exposure time of 5 ns show that the uniform surface air discharge can be generated during the rising and falling time of pulsed DC voltage. Current and voltage and optical measurements confirm the formation of glow-like air discharges on the surface of micron-sized dielectric tubes. Simulation results indicate that the microelectrode configuration contributes to the formation of strong surface electric field and plays an important role in the generation of uniformmore » surface air discharge.« less
MR Persei - A new rotating, spotted flare star
NASA Technical Reports Server (NTRS)
Honeycutt, R. K.; Turner, G. W.; Vesper, D. N.; Schlegel, E. M.
1992-01-01
Spectroscopy and photometry are used to show that MR Persei, an object originally classified as a dwarf nova, is in fact a flare star. The automated CCD photometry consists of sequences of exposures within a single night as well as long-term photometry over a five-month interval. One sequence shows a 30-min flare, accompanied by post-flare 'dips'. A 0.2 mag variation with a period of about one-half day is also seen in this sequence. The long-term photometry is used to refine the period to 0.45483 d, which we attribute to the rotation of a spotted star. Evidence for membership of MR Per in the young Alpha Per cluster is considered, and found to be inconclusive.
SPECKLE INTERFEROMETRY AT THE U.S. NAVAL OBSERVATORY. XIX
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason, Brian D.; Hartkopf, William I.; Hurowitz, Haley M., E-mail: bdm@usno.navy.mil, E-mail: wih@usno.navy.mil, E-mail: hurowitz@mit.edu
2013-09-15
The results of 2916 intensified CCD observations of double stars, made with the 26 inch refractor of the U.S. Naval Observatory, are presented. Each observation of a system represents a combination of over two thousand short-exposure images. These observations are averaged into 1584 mean relative positions and range in separation from 0.''54 to 98.''09, with a median separation of 11.''73. This is the 19th in this series of papers and covers the period 2012 January 5 through 2012 December 18. Also presented are 10 pairs that are reported for the first time, 17 pairs that appear to be lost, linearmore » elements for 18 pairs, and orbital elements for 2 additional pairs.« less
High resolution in galaxy photometry and imaging
NASA Astrophysics Data System (ADS)
Nieto, J.-L.; Lelievre, G.
Techniques for increasing the resolution of ground-based photometric observations of galaxies are discussed. The theoretical limitations on resolution and their implications for choosing telescope size at a given site considered, with an emphasis on the importance of the Fried (1966) parameter r0. The techniques recommended are shortening exposure time, selection of the highest-resolution images, and a posteriori digital image processing (as opposed to active-mirror image stabilization or the cine-CCD system of Fort et al., 1984). The value of the increased resolution (by a factor of 2) achieved at Pic du Midi observatory for studies of detailed structure in extragalactic objects, for determining the distance to galaxies, and for probing the central cores of galaxies is indicated.
NASA Astrophysics Data System (ADS)
Xu, S. J.; Zhang, Y. H.; Yu, Z.; Yao, J.; Zhang, Z. T.
2013-03-01
The streamer regime of pin-to-plane dielectric barrier discharge in air was studied by means of fast photography, electrical measurement and photoelectricity. The fast photographs of positive streamer were obtained by CCD camera with micro lens. The exposure time is one microseconds. The images illustrate that the streamer is non-axisymmetric because of some random factors, such as surface charge position, space charge distribution, gas liquidity and so on. In fact, the streamer propagates along bend discharge channel. The bending degree increases with the electric field strengthen. By surveying a mass of images, the diameter of streamer, height of surface charge effect and scope of surface charge was estimate used to describe the shape of streamer.
VizieR Online Data Catalog: Abundance ratio for 5 local stellar associations (Reddy+, 2015)
NASA Astrophysics Data System (ADS)
Reddy, A. B. S.; Lambert, D. L.
2018-01-01
In this paper, we have performed a homogeneous and a comprehensive abundance analysis using high-resolution spectroscopy. High-resolution and high signal-to-noise (S/N) spectra of the program stars were obtained during the nights of 2015 February 10-11 with the Robert G. Tull coude cross-dispersed echelle spectrograph (Tull et al. 1995PASP..107..251T) of the 2.7 m Harlan J. Smith reflector at the McDonald Observatory. We employed a Tektronix 2048x2048 24 μm pixel, backside illuminated and anti-reflection coated CCD as a detector and an R2 echelle grating with 52.67 grooves/mm with exposures centred at 5060 Å. (7 data files).
Intelligent error correction method applied on an active pixel sensor based star tracker
NASA Astrophysics Data System (ADS)
Schmidt, Uwe
2005-10-01
Star trackers are opto-electronic sensors used on-board of satellites for the autonomous inertial attitude determination. During the last years star trackers became more and more important in the field of the attitude and orbit control system (AOCS) sensors. High performance star trackers are based up today on charge coupled device (CCD) optical camera heads. The active pixel sensor (APS) technology, introduced in the early 90-ties, allows now the beneficial replacement of CCD detectors by APS detectors with respect to performance, reliability, power, mass and cost. The company's heritage in star tracker design started in the early 80-ties with the launch of the worldwide first fully autonomous star tracker system ASTRO1 to the Russian MIR space station. Jena-Optronik recently developed an active pixel sensor based autonomous star tracker "ASTRO APS" as successor of the CCD based star tracker product series ASTRO1, ASTRO5, ASTRO10 and ASTRO15. Key features of the APS detector technology are, a true xy-address random access, the multiple windowing read out and the on-chip signal processing including the analogue to digital conversion. These features can be used for robust star tracking at high slew rates and under worse conditions like stray light and solar flare induced single event upsets. A special algorithm have been developed to manage the typical APS detector error contributors like fixed pattern noise (FPN), dark signal non-uniformity (DSNU) and white spots. The algorithm works fully autonomous and adapts to e.g. increasing DSNU and up-coming white spots automatically without ground maintenance or re-calibration. In contrast to conventional correction methods the described algorithm does not need calibration data memory like full image sized calibration data sets. The application of the presented algorithm managing the typical APS detector error contributors is a key element for the design of star trackers for long term satellite applications like geostationary telecom platforms.
Candidate enzymes for saffron crocin biosynthesis are localized in multiple cellular compartments.
Demurtas, Olivia Costantina; Frusciante, Sarah; Ferrante, Paola; Diretto, Gianfranco; Azad, Noraddin Hosseinpour; Pietrella, Marco; Aprea, Giuseppe; Taddei, Anna Rita; Romano, Elena; Mi, Jianing; Al-Babili, Salim; Frigerio, Lorenzo; Giuliano, Giovanni
2018-05-29
Saffron is composed of the dried stigmas of Crocus sativus and is the most expensive spice on Earth. Its red color is due to the apocarotenoid glycosides, crocins, which accumulate in the vacuole and reach up to 10% of the stigma dry weight. We have previously characterized the first dedicated enzyme in crocin biosynthesis, CsCCD2, which cleaves zeaxanthin to yield crocetin dialdehyde. In this work, we identified six putative aldehyde dehydrogenase (ALDH) transcripts expressed in saffron stigmas. When expressed in E. coli, only one of corresponding proteins (CsALDH3I1), was able to convert crocetin dialdehyde into the crocin precursor, crocetin. CsALDH3I1 carries a C-terminal hydrophobic domain, similar to that of a Neurospora membrane-associated apocarotenoid dehydrogenase, YLO-1. We also characterized a UDP-glycosyltransferase enzyme, CsUGT74AD1, able to convert crocetin to crocins 1 and 2'. In vitro assays showed high specificity of CsALDH3I1 for crocetin dialdehyde and long chain apocarotenals, and of CsUGT74AD1 for crocetin. Upon extract fractionation, the CsCCD2, CsALDH3I1 and CsUGT74AD1 enzymes partitioned in the insoluble fraction, suggesting that they are associated to membranes or to large insoluble complexes. Immunogold labeling of saffron stigmas and confocal microscopy of fusions to Green Fluorescent Protein expressed in N. benthamiana leaves revealed that CsCCD2 localizes to plastids, CsALDH3I1 to the endoplasmic reticulum (ER) and CsUGT74AD1 to the cytoplasm, in association with cytoskeletal-like structures. Based on our and on literature data, we propose that the ER and cytoplasm function as "transit centers" for metabolites whose biosynthesis starts in the plastid and are accumulated in the vacuole. {copyright, serif} 2018 American Society of Plant Biologists. All rights reserved.
Speckle contrast diffuse correlation tomography of complex turbid medium flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Chong; Irwin, Daniel; Lin, Yu
2015-07-15
Purpose: Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckle contrast diffuse correlation tomography (scDCT), enables incorporation of complex optical property heterogeneities and sample boundaries. When combined with a reflectance-based design, this system facilitates a rapid segue into flow contrast imaging of larger, in vivo applications such as humans. Methods: A highly sensitive CCD camera was integrated into a reflectance-based optical system. Four long-coherence laser source positions were coupledmore » to an optical switch for sequencing of tomographic data acquisition providing multiple projections through the sample. This system was investigated through incorporation of liquid and solid tissue-like phantoms exhibiting optical properties and flow characteristics typical of human tissues. Computer simulations were also performed for comparisons. A uniquely encountered smear correction algorithm was employed to correct point-source illumination contributions during image capture with the frame-transfer CCD and reflectance setup. Results: Measurements with scDCT on a homogeneous liquid phantom showed that speckle contrast-based deep flow indices were within 12% of those from standard DCT. Inclusion of a solid phantom submerged below the liquid phantom surface allowed for heterogeneity detection and validation. The heterogeneity was identified successfully by reconstructed 3D flow contrast tomography with scDCT. The heterogeneity center and dimensions and averaged relative flow (within 3%) and localization were in agreement with actuality and computer simulations, respectively. Conclusions: A custom cost-effective CCD-based reflectance 3D flow imaging system demonstrated rapid acquisition of dense boundary data and, with further studies, a high potential for translatability to real tissues with arbitrary boundaries. A requisite correction was also found for measurements in the fashion of scDCT to recover accurate speckle contrast of deep tissues.« less
NASA Astrophysics Data System (ADS)
Song, Qing; Zhu, Sijia; Yan, Han; Wu, Wenqian
2008-03-01
Parallel light projection method for the diameter measurement is to project the workpiece to be measured on the photosensitive units of CCD, but the original signal output from CCD cannot be directly used for counting or measurement. The weak signal with high-frequency noise should be filtered and amplified firstly. This paper introduces RC low-pass filter and multiple feed-back second-order low-pass filter with infinite gain. Additionally there is always dispersion on the light band and the output signal has a transition between the irradiant area and the shadow, because of the instability of the light source intensity and the imperfection of the light system adjustment. To obtain exactly the shadow size related to the workpiece diameter, binary-value processing is necessary to achieve a square wave. Comparison method and differential method can be adopted for binary-value processing. There are two ways to decide the threshold value when using voltage comparator: the fixed level method and the floated level method. The latter has a high accuracy. Deferential method is to output two spike pulses with opposite pole by the rising edge and the failing edge of the video signal related to the differential circuit firstly, then the rising edge of the signal output from the differential circuit is acquired by half-wave rectifying circuit. After traveling through the zero passing comparator and the maintain- resistance edge trigger, the square wave which indicates the measured size is acquired at last. And then it is used for filling through standard pulses and for counting through the counter. Data acquisition and information processing is accomplished by the computer and the control software. This paper will introduce in detail the design and analysis of the filter circuit, binary-value processing circuit and the interface circuit towards the computer.
SU-C-207A-03: Development of Proton CT Imaging System Using Thick Scintillator and CCD Camera
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanaka, S; Uesaka, M; Nishio, T
2016-06-15
Purpose: In the treatment planning of proton therapy, Water Equivalent Length (WEL), which is the parameter for the calculation of dose and the range of proton, is derived by X-ray CT (xCT) image and xCT-WEL conversion. However, about a few percent error in the accuracy of proton range calculation through this conversion has been reported. The purpose of this study is to construct a proton CT (pCT) imaging system for an evaluation of the error. Methods: The pCT imaging system was constructed with a thick scintillator and a cooled CCD camera, which acquires the two-dimensional image of integrated value ofmore » the scintillation light toward the beam direction. The pCT image is reconstructed by FBP method using a correction between the light intensity and residual range of proton beam. An experiment for the demonstration of this system was performed with 70-MeV proton beam provided by NIRS cyclotron. The pCT image of several objects reconstructed from the experimental data was evaluated quantitatively. Results: Three-dimensional pCT images of several objects were reconstructed experimentally. A finestructure of approximately 1 mm was clearly observed. The position resolution of pCT image was almost the same as that of xCT image. And the error of proton CT pixel value was up to 4%. The deterioration of image quality was caused mainly by the effect of multiple Coulomb scattering. Conclusion: We designed and constructed the pCT imaging system using a thick scintillator and a CCD camera. And the system was evaluated with the experiment by use of 70-MeV proton beam. Three-dimensional pCT images of several objects were acquired by the system. This work was supported by JST SENTAN Grant Number 13A1101 and JSPS KAKENHI Grant Number 15H04912.« less
Event-Driven X-Ray CCD Detectors for High Energy Astrophysics
NASA Technical Reports Server (NTRS)
Ricker, George R.
2004-01-01
A viewgraph presentation describing the Event-Driven X- Ray CCD (EDCCD) detector system for high energy astrophysics is presented. The topics include: 1) EDCCD: Description and Advantages; 2) Summary of Grant Activity Carried Out; and 3) EDCCD Test System.
Study of digital charge coupled devices
NASA Technical Reports Server (NTRS)
Wilson, D. D.; Young, V. F.
1980-01-01
Charge coupled devices represent unique usage of the metal oxide semiconductor concept. These devices can sample an AC signal at the input, transfer charge proportional to this signal through the CCD shift register and then provide an output of the same frequency and shape as the input. The delay time between input and output is controlled by the CCD operating frequency and the number of stages in the shift resistor. This work is a reliability evaluation of the buried channel and surface channel CCD technologies. The constructions are analyzed, failure modes are described, and test results are reported.
NASA Astrophysics Data System (ADS)
Vishnevsky, G. I.; Galyatkin, I. A.; Zhuk, A. A.; Iblyaminova, A. F.; Kossov, V. G.; Levko, G. V.; Nesterov, V. K.; Rivkind, V. L.; Rogalev, Yu. N.; Smirnov, A. V.; Gumerov, R. I.; Bikmaev, I. F.; Pinigin, G. I.; Shulga, A. V.; Kovalchyk, A. V.; Protsyuk, Yu. I.; Malevinsky, S. V.; Abrosimov, V. M.; Mironenko, V. N.; Savchenko, V. V.; Ivaschenko, Yu. N.; Andruk, V. M.; Dalinenko, I. N.; Vydrevich, M. G.
2003-01-01
The paper presents the possibilities and a list of tasks that are solved by collaboration between research and production companies, and astronomical observatories of Russia and Ukraine in the field of development, modernization and equipping of various telescopes (the AMC, RTT-150, Zeiss-600 and quantum-optical system Sazhen-S types) with advanced charge-coupled device (CCD) cameras. CCD imagers and ditital CCD cameras designed and manufactured by the "Electron-Optronic" Research & Production Company, St Petersburg, to equip astronomical telescopes and scientific instruments are described.
ESA's CCD test bench for the PLATO mission
NASA Astrophysics Data System (ADS)
Beaufort, Thierry; Duvet, Ludovic; Bloemmaert, Sander; Lemmel, Frederic; Prod'homme, Thibaut; Verhoeve, Peter; Smit, Hans; Butler, Bart; van der Luijt, Cornelis; Heijnen, Jerko; Visser, Ivo
2016-08-01
PLATO { PLAnetary Transits and Oscillations of stars { is the third medium-class mission to be selected in the European Space Agency (ESA) Science and Robotic Exploration Cosmic Vision programme. Due for launch in 2025, the payload makes use of a large format (8 cm x 8 cm) Charge-Coupled Devices (CCDs), the e2v CCD270 operated at 4 MHz and at -70 C. To de-risk the PLATO CCD qualification programme initiated in 2014 and support the mission definition process, ESA's Payload Technology Validation section from the Future Missions Office has developed a dedicated test bench.
The study of surface acoustic wave charge transfer device
NASA Technical Reports Server (NTRS)
Papanicolaou, N.; Lin, H. C.
1978-01-01
A surface acoustic wave-charge transfer device, consisting of an n-type silicon substrate, a thermally grown silicon dioxide layer, and a sputtered film of piezoelectric zinc oxide is proposed as a means of circumventing problems associated with charge-coupled device (CCD) applications in memory, signal processing, and imaging. The proposed device creates traveling longitudinal electric fields in the silicon and replaces the multiphase clocks in CCD's. The traveling electric fields create potential wells which carry along charges stored there. These charges may be injected into the wells by light or by using a p-n junction as in conventional CCD's.
Hou, Chunsheng; Rivkin, Hadassah; Slabezki, Yossi; Chejanovsky, Nor
2014-05-05
The determinants of Colony Collapse Disorder (CCD), a particular case of collapse of honey bee colonies, are still unresolved. Viruses including the Israeli acute paralysis virus (IAPV) were associated with CCD. We found an apiary with colonies showing typical CCD characteristics that bore high loads of IAPV, recovered some colonies from collapse and tested the hypothesis if IAPV was actively replicating in them and infectious to healthy bees. We found that IAPV was the dominant pathogen and it replicated actively in the colonies: viral titers decreased from April to September and increased from September to December. IAPV extracted from infected bees was highly infectious to healthy pupae: they showed several-fold amplification of the viral genome and synthesis of the virion protein VP3. The health of recovered colonies was seriously compromised. Interestingly, a rise of IAPV genomic copies in two colonies coincided with their subsequent collapse. Our results do not imply IAPV as the cause of CCD but indicate that once acquired and induced to replication it acts as an infectious factor that affects the health of the colonies and may determine their survival. This is the first follow up outside the US of CCD-colonies bearing IAPV under natural conditions.
Hou, Chunsheng; Rivkin, Hadassah; Slabezki, Yossi; Chejanovsky, Nor
2014-01-01
The determinants of Colony Collapse Disorder (CCD), a particular case of collapse of honey bee colonies, are still unresolved. Viruses including the Israeli acute paralysis virus (IAPV) were associated with CCD. We found an apiary with colonies showing typical CCD characteristics that bore high loads of IAPV, recovered some colonies from collapse and tested the hypothesis if IAPV was actively replicating in them and infectious to healthy bees. We found that IAPV was the dominant pathogen and it replicated actively in the colonies: viral titers decreased from April to September and increased from September to December. IAPV extracted from infected bees was highly infectious to healthy pupae: they showed several-fold amplification of the viral genome and synthesis of the virion protein VP3. The health of recovered colonies was seriously compromised. Interestingly, a rise of IAPV genomic copies in two colonies coincided with their subsequent collapse. Our results do not imply IAPV as the cause of CCD but indicate that once acquired and induced to replication it acts as an infectious factor that affects the health of the colonies and may determine their survival. This is the first follow up outside the US of CCD-colonies bearing IAPV under natural conditions. PMID:24800677
Line scanning system for direct digital chemiluminescence imaging of DNA sequencing blots
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karger, A.E.; Weiss, R.; Gesteland, R.F.
A cryogenically cooled charge-coupled device (CCD) camera equipped with an area CCD array is used in a line scanning system for low-light-level imaging of chemiluminescent DNA sequencing blots. Operating the CCD camera in time-delayed integration (TDI) mode results in continuous data acquisition independent of the length of the CCD array. Scanning is possible with a resolution of 1.4 line pairs/mm at the 50% level of the modulation transfer function. High-sensitivity, low-light-level scanning of chemiluminescent direct-transfer electrophoresis (DTE) DNA sequencing blots is shown. The detection of DNA fragments on the blot involves DNA-DNA hybridization with oligonucleotide-alkaline phosphatase conjugate and 1,2-dioxetane-based chemiluminescence.more » The width of the scan allows the recording of up to four sequencing reactions (16 lanes) on one scan. The scan speed of 52 cm/h used for the sequencing blots corresponds to a data acquisition rate of 384 pixels/s. The chemiluminescence detection limit on the scanned images is 3.9 [times] 10[sup [minus]18] mol of plasmid DNA. A conditional median filter is described to remove spikes caused by cosmic ray events from the CCD images. 39 refs., 9 refs.« less
Defect inspection in hot slab surface: multi-source CCD imaging based fuzzy-rough sets method
NASA Astrophysics Data System (ADS)
Zhao, Liming; Zhang, Yi; Xu, Xiaodong; Xiao, Hong; Huang, Chao
2016-09-01
To provide an accurate surface defects inspection method and make the automation of robust image region of interests(ROI) delineation strategy a reality in production line, a multi-source CCD imaging based fuzzy-rough sets method is proposed for hot slab surface quality assessment. The applicability of the presented method and the devised system are mainly tied to the surface quality inspection for strip, billet and slab surface etcetera. In this work we take into account the complementary advantages in two common machine vision (MV) systems(line array CCD traditional scanning imaging (LS-imaging) and area array CCD laser three-dimensional (3D) scanning imaging (AL-imaging)), and through establishing the model of fuzzy-rough sets in the detection system the seeds for relative fuzzy connectedness(RFC) delineation for ROI can placed adaptively, which introduces the upper and lower approximation sets for RIO definition, and by which the boundary region can be delineated by RFC region competitive classification mechanism. For the first time, a Multi-source CCD imaging based fuzzy-rough sets strategy is attempted for CC-slab surface defects inspection that allows an automatic way of AI algorithms and powerful ROI delineation strategies to be applied to the MV inspection field.
Ilg, Andrea; Bruno, Mark; Beyer, Peter; Al-Babili, Salim
2014-01-01
The biosynthetic processes leading to many of the isoprenoid volatiles released by tomato fruits are still unknown, though previous reports suggested a clear correlation with the carotenoids contained within the fruit. In this study, we investigated the activity of the tomato (Solanum lycopersicum) carotenoid cleavage dioxygenase (SlCCD1B), which is highly expressed in fruits, and of its homolog SlCCD1A. Using in vitro assays performed with purified recombinant enzymes and by analyzing products formed by the two enzymes in carotene-accumulating Escherichia coli strains, we demonstrate that SlCCD1A and, to a larger extent, SlCCD1B, have a very relaxed specificity for both substrate and cleavage site, mediating the oxidative cleavage of cis- and all-trans-carotenoids as well as of different apocarotenoids at many more double bonds than previously reported. This activity gives rise to a plenitude of volatiles, mono-apocarotenoids and dialdehyde products, including cis-pseudoionone, neral, geranial, and farnesylacetone. Our results provide a direct evidence for a carotenoid origin of these compounds and point to CCD1s as the enzymes catalyzing the formation of the vast majority of tomato isoprenoid volatiles, many of which are aroma constituents. PMID:25057464
Koottathape, Natthavoot; Takahashi, Hidekazu; Finger, Wernerj; Kanehira, Masafumi; Iwasaki, Naohiko; Aoyagi, Yujin
2012-06-01
Although attritive and abrasive wear of recent composite resins has been substantially reduced, in vitro wear testing with reasonably simulating devices and quantitative determination of resulting wear is still needed. Three-dimensional scanning methods are frequently used for this purpose. The aim of this trial was to compare maximum depth of wear and volume loss of composite samples, evaluated with a contact profilometer and a non-contact CCD camera imaging system, respectively. Twenty-three random composite specimens with wear traces produced in a ball-on-disc sliding device, using poppy seed slurry and PMMA suspension as third-body media, were evaluated with the contact profilometer (TalyScan 150, Taylor Hobson LTD, Leicester, UK) and with the digital CCD microscope (VHX1000, KEYENCE, Osaka, Japan). The target parameters were maximum depth of the wear and volume loss.Results - The individual time of measurement needed with the non-contact CCD method was almost three hours less than that with the contact method. Both, maximum depth of wear and volume loss data, recorded with the two methods were linearly correlated (r(2) > 0.97; p < 0.01). The contact scanning method and the non-contact CCD method are equally suitable for determination of maximum depth of wear and volume loss of abraded composite resins.
Strigolactone regulation of shoot branching in chrysanthemum (Dendranthema grandiflorum)
Liang, Jianli; Zhao, Liangjun; Challis, Richard; Leyser, Ottoline
2010-01-01
Previous studies of highly branched mutants in pea (rms1–rms5), Arabidopsis thaliana (max1–max4), petunia (dad1–dad3), and rice (d3, d10, htd1/d17, d14, d27) identified strigolactones or their derivates (SLs), as shoot branching inhibitors. This recent discovery offers the possibility of using SLs to regulate branching commercially, for example, in chrysanthemum, an important cut flower crop. To investigate this option, SL physiology and molecular biology were studied in chrysanthemum (Dendranthema grandiflorum), focusing on the CCD8/MAX4/DAD1/RMS1/D10 gene. Our results suggest that, as has been proposed for Arabidopsis, the ability of SLs to inhibit bud activity depends on the presence of a competing auxin source. The chrysanthemum SL biosynthesis gene, CCD8 was cloned, and found to be regulated in a similar, but not identical way to known CCD8s. Expression analyses revealed that DgCCD8 is predominantly expressed in roots and stems, and is up-regulated by exogenous auxin. Exogenous SL can down-regulate DgCCD8 expression, but this effect can be overridden by apical auxin application. This study provides evidence that SLs are promising candidates to alter the shoot branching habit of chrysanthemum. PMID:20478970
Sánchez, Brisa N; Kang, Shan; Mukherjee, Bhramar
2012-06-01
Many existing cohort studies initially designed to investigate disease risk as a function of environmental exposures have collected genomic data in recent years with the objective of testing for gene-environment interaction (G × E) effects. In environmental epidemiology, interest in G × E arises primarily after a significant effect of the environmental exposure has been documented. Cohort studies often collect rich exposure data; as a result, assessing G × E effects in the presence of multiple exposure markers further increases the burden of multiple testing, an issue already present in both genetic and environment health studies. Latent variable (LV) models have been used in environmental epidemiology to reduce dimensionality of the exposure data, gain power by reducing multiplicity issues via condensing exposure data, and avoid collinearity problems due to presence of multiple correlated exposures. We extend the LV framework to characterize gene-environment interaction in presence of multiple correlated exposures and genotype categories. Further, similar to what has been done in case-control G × E studies, we use the assumption of gene-environment (G-E) independence to boost the power of tests for interaction. The consequences of making this assumption, or the issue of how to explicitly model G-E association has not been previously investigated in LV models. We postulate a hierarchy of assumptions about the LV model regarding the different forms of G-E dependence and show that making such assumptions may influence inferential results on the G, E, and G × E parameters. We implement a class of shrinkage estimators to data adaptively trade-off between the most restrictive to most flexible form of G-E dependence assumption and note that such class of compromise estimators can serve as a benchmark of model adequacy in LV models. We demonstrate the methods with an example from the Early Life Exposures in Mexico City to Neuro-Toxicants Study of lead exposure, iron metabolism genes, and birth weight. © 2011, The International Biometric Society.
NASA Astrophysics Data System (ADS)
Cajgfinger, Thomas; Chabanat, Eric; Dominjon, Agnes; Doan, Quang T.; Guerin, Cyrille; Houles, Julien; Barbier, Remi
2011-03-01
Nano-biophotonics applications will benefit from new fluorescent microscopy methods based essentially on super-resolution techniques (beyond the diffraction limit) on large biological structures (membranes) with fast frame rate (1000 Hz). This trend tends to push the photon detectors to the single-photon counting regime and the camera acquisition system to real time dynamic multiple-target tracing. The LUSIPHER prototype presented in this paper aims to give a different approach than those of Electron Multiplied CCD (EMCCD) technology and try to answer to the stringent demands of the new nano-biophotonics imaging techniques. The electron bombarded CMOS (ebCMOS) device has the potential to respond to this challenge, thanks to the linear gain of the accelerating high voltage of the photo-cathode, to the possible ultra fast frame rate of CMOS sensors and to the single-photon sensitivity. We produced a camera system based on a 640 kPixels ebCMOS with its acquisition system. The proof of concept for single-photon based tracking for multiple single-emitters is the main result of this paper.
Structure Formation in Complex Plasma
2011-08-24
Dewer bottle (upper figures) or in the vapor of liquid helium (lower figures). Liq. He Ring electrode Particles Green Laser RF Plasma ... Ring electrode CCD camera Prism mirror Liq. He Glass Tube Liq. N2 Glass Dewar Acrylic particles Gas Helium Green Laser CCD camera Pressure
Sun Exposure, Vitamin D Receptor Polymorphisms FokI and BsmI and Risk of Multiple Primary Melanoma
Mandelcorn-Monson, Rochelle; Marrett, Loraine; Kricker, Anne; Armstrong, Bruce K.; Orlow, Irene; Goumas, Chris; Paine, Susan; Rosso, Stefano; Thomas, Nancy; Millikan, Robert C.; Pole, Jason D.; Cotignola, Javier; Rosen, Cheryl; Kanetsky, Peter A.; Lee-Taylor, Julia; Begg, Colin B.; Berwick, Marianne
2011-01-01
Sunlight exposure increases risk of melanoma. Sunlight also potentiates cutaneous synthesis of vitamin D, which can inhibit melanoma cell growth and promote apoptosis. Vitamin D effects are mediated through the vitamin D receptor (VDR). We hypothesized that genetic variation in VDR affects the relationship of sun exposure to risk of a further melanoma in people who have already had one. We investigated the interaction between VDR polymorphisms and sun exposure in a population-based multinational study comparing 1138 patients with a multiple (second or subsequent) primary melanoma (cases) to 2151 patients with a first primary melanoma (controls); essentially a case-control study of melanoma in a population of melanoma survivors. Sun exposure was assessed using a questionnaire and interview, and was shown to be associated with multiple primary melanoma. VDR was genotyped at the FokI and BsmI loci and the main effects of variants at these loci and their interactions with sun exposure were analyzed. Only the BsmI variant was associated with multiple primary melanoma (OR = 1.27, 95% CI 0.99-1.62 for the homozygous variant genotype). Joint effects analyses showed highest ORs in the high exposure, homozygous variant BsmI genotype category for each sun exposure variable. Stratified analyses showed somewhat higher ORs for the homozygous BsmI variant genotype in people with high sun exposure than with low sun exposure. P values for interaction, however, were high. These results suggest that risk of multiple primary melanoma is increased in people who have the BsmI variant of VDR. PMID:21612999
Kordas, Katarzyna; Ardoino, Graciela; Coffman, Donna L.; Queirolo, Elena I.; Ciccariello, Daniela; Mañay, Nelly; Ettinger, Adrienne S.
2015-01-01
While it is known that toxic metals contribute individually to child cognitive and behavioral deficits, we still know little about the effects of exposure to multiple metals, particularly when exposures are low. We studied the association between children's blood lead and hair arsenic, cadmium, and manganese and their performance on the Bayley Scales of Infant Development III. Ninety-two preschool children (age 13–42 months) from Montevideo, Uruguay, provided a hair sample and 78 had a blood lead level (BLL) measurement. Using latent class analysis (LCA), we identified four groups of exposure based on metal concentrations: (1) low metals, (2) low-to-moderate metals, (3) high lead and cadmium, and (4) high metals. Using the four-group exposure variable as the main predictor, and fitting raw scores on the cognitive, receptive vocabulary, and expressive vocabulary scales as dependent variables, both complete-case and multiple imputation (MI) analyses were conducted. We found no association between multiple-metal exposures and neurodevelopment in covariate-adjusted models. This study demonstrates the use of LCA together with MI to determine patterns of exposure to multiple toxic metals and relate these to child neurodevelopment. However, because the overall study population was small, other studies with larger sample sizes are needed to investigate these associations. PMID:25694786
The Modeling Environment for Total Risks studies (MENTOR) system, combined with an extension of the SHEDS (Stochastic Human Exposure and Dose Simulation) methodology, provide a mechanistically consistent framework for conducting source-to-dose exposure assessments of multiple pol...