NASA Astrophysics Data System (ADS)
Ikelle, Luc T.
2006-02-01
We here describe one way of constructing internal multiples from surface seismic data only. The key feature of our construct of internal multiples is the introduction of the concept of virtual seismic events. Virtual events here are events, which are not directly recorded in standard seismic data acquisition, but their existence allows us to construct internal multiples with scattering points at the sea surface; the standard construct of internal multiples does not include any scattering points at the sea surface. The mathematical and computational operations invoked in our construction of virtual events and internal multiples are similar to those encountered in the construction of free-surface multiples based on the Kirchhoff or Born scattering theory. For instance, our construct operates on one temporal frequency at a time, just like free-surface demultiple algorithms; other internal multiple constructs tend to require all frequencies for the computation of an internal multiple at a given frequency. It does not require any knowledge of the subsurface nor an explicit knowledge of specific interfaces that are responsible for the generation of internal multiples in seismic data. However, our construct requires that the data be divided into two, three or four windows to avoid generating primaries. This segmentation of the data also allows us to select a range of periods of internal multiples that one wishes to construct because, in the context of the attenuation of internal multiples, it is important to avoid generating short-period internal multiples that may constructively average to form primaries at the seismic scale.
Global multiplicity of dietary standards for trace elements.
Freeland-Graves, Jeanne H; Lee, Jane J
2012-06-01
Consistent guidelines across the world for dietary standards of trace elements remain elusive. Harmonization of dietary standards has been suggested by international agencies to facilitate consistency in food and nutrition policies and international trade. Yet significant barriers exist to standardize recommendations on a global basis, such as vast differences in geography, food availability and transport; cultural, social and economic constraints, and biological diversity. Simple commonality is precluded further by the variety of terminologies among countries and regions related to diet. Certain unions have created numerous nutritional descriptive categories for standards, while other large countries are limited to only a few. This paper will explore the global multiplicity of dietary standards and efforts for harmonization. Copyright © 2012 Elsevier GmbH. All rights reserved.
Tsuchiyama, Tomoyuki; Katsuhara, Miki; Nakajima, Masahiro
2017-11-17
In the multi-residue analysis of pesticides using GC-MS, the quantitative results are adversely affected by a phenomenon known as the matrix effect. Although the use of matrix-matched standards is considered to be one of the most practical solutions to this problem, complete removal of the matrix effect is difficult in complex food matrices owing to their inconsistency. As a result, residual matrix effects can introduce analytical errors. To compensate for residual matrix effects, we have developed a novel method that employs multiple isotopically labeled internal standards (ILIS). The matrix effects of ILIS and pesticides were evaluated in spiked matrix extracts of various agricultural commodities, and the obtained data were subjected to simple statistical analysis. Based on the similarities between the patterns of variation in the analytical response, a total of 32 isotopically labeled compounds were assigned to 338 pesticides as internal standards. It was found that by utilizing multiple ILIS, residual matrix effects could be effectively compensated. The developed method exhibited superior quantitative performance compared with the common single-internal-standard method. The proposed method is more feasible for regulatory purposes than that using only predetermined correction factors and is considered to be promising for practical applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Song, Mi; Chen, Zeng-Ping; Chen, Yao; Jin, Jing-Wen
2014-07-01
Liquid chromatography-mass spectrometry assays suffer from signal instability caused by the gradual fouling of the ion source, vacuum instability, aging of the ion multiplier, etc. To address this issue, in this contribution, an internal standard was added into the mobile phase. The internal standard was therefore ionized and detected together with the analytes of interest by the mass spectrometer to ensure that variations in measurement conditions and/or instrument have similar effects on the signal contributions of both the analytes of interest and the internal standard. Subsequently, based on the unique strategy of adding internal standard in mobile phase, a multiplicative effects model was developed for quantitative LC-MS assays and tested on a proof of concept model system: the determination of amino acids in water by LC-MS. The experimental results demonstrated that the proposed method could efficiently mitigate the detrimental effects of continuous signal variation, and achieved quantitative results with average relative predictive error values in the range of 8.0-15.0%, which were much more accurate than the corresponding results of conventional internal standard method based on the peak height ratio and partial least squares method (their average relative predictive error values were as high as 66.3% and 64.8%, respectively). Therefore, it is expected that the proposed method can be developed and extended in quantitative LC-MS analysis of more complex systems. Copyright © 2014 Elsevier B.V. All rights reserved.
Fortini, Martina; Migliorini, Marzia; Cherubini, Chiara; Cecchi, Lorenzo; Calamai, Luca
2017-04-01
The commercial value of virgin olive oils (VOOs) strongly depends on their classification, also based on the aroma of the oils, usually evaluated by a panel test. Nowadays, a reliable analytical method is still needed to evaluate the volatile organic compounds (VOCs) and support the standard panel test method. To date, the use of HS-SPME sampling coupled to GC-MS is generally accepted for the analysis of VOCs in VOOs. However, VOO is a challenging matrix due to the simultaneous presence of: i) compounds at ppm and ppb concentrations; ii) molecules belonging to different chemical classes and iii) analytes with a wide range of molecular mass. Therefore, HS-SPME-GC-MS quantitation based upon the use of external standard method or of only a single internal standard (ISTD) for data normalization in an internal standard method, may be troublesome. In this work a multiple internal standard normalization is proposed to overcome these problems and improving quantitation of VOO-VOCs. As many as 11 ISTDs were used for quantitation of 71 VOCs. For each of them the most suitable ISTD was selected and a good linearity in a wide range of calibration was obtained. Except for E-2-hexenal, without ISTD or with an unsuitable ISTD, the linear range of calibration was narrower with respect to that obtained by a suitable ISTD, confirming the usefulness of multiple internal standard normalization for the correct quantitation of VOCs profile in VOOs. The method was validated for 71 VOCs, and then applied to a series of lampante virgin olive oils and extra virgin olive oils. In light of our results, we propose the application of this analytical approach for routine quantitative analyses and to support sensorial analysis for the evaluation of positive and negative VOOs attributes. Copyright © 2017 Elsevier B.V. All rights reserved.
Database of Standardized Questionnaires About Walking & Bicycling
This database contains questionnaire items and a list of validation studies for standardized items related to walking and biking. The items come from multiple national and international physical activity questionnaires.
Three-Drug Combination for Relapsed Multiple Myeloma
A summary of Interim results from an international, randomized phase III trial that suggest that adding carfilzomib (Kyprolis®) to a standard treatment improves outcomes for patients with multiple myeloma whose cancer has relapsed.
Systematic Review of International Colposcopy Quality Improvement Guidelines.
Mayeaux, Edward J; Novetsky, Akiva P; Chelmow, David; Choma, Kim; Garcia, Francisco; Liu, Angela H; Papasozomenos, Theognosia; Einstein, Mark H
2017-10-01
The American Society for Colposcopy and Cervical Pathology Colposcopy Standards Committee organized multiple working groups to draft colposcopy standards for the United States. As part of this project, international quality assurance and improvement measures were examined. The quality improvement working group performed a systematic review of the literature to collate international guidelines related to quality improvement. Source guidelines were collected using searches in Medline, Google Scholar, the International Federation of Cervical Pathology and Colposcopy Web site, other regional colposcopy group's Web sites, and communications with International Federation of Cervical Pathology and Colposcopy board of directors' members and other expert members of various national groups. Once identified, the sources were reviewed by multiple workgroup members for potential guideline materials. Fifty-six unique documents were identified, of which 18 met inclusion criteria and contributed data to the analysis. Information was abstracted and grouped by related subject. Wide variation exists in colposcopy guidance and quality indicators from regional and national colposcopy societies. Abstracted international guidelines are presented.
Seismic reflection imaging, accounting for primary and multiple reflections
NASA Astrophysics Data System (ADS)
Wapenaar, Kees; van der Neut, Joost; Thorbecke, Jan; Broggini, Filippo; Slob, Evert; Snieder, Roel
2015-04-01
Imaging of seismic reflection data is usually based on the assumption that the seismic response consists of primary reflections only. Multiple reflections, i.e. waves that have reflected more than once, are treated as primaries and are imaged at wrong positions. There are two classes of multiple reflections, which we will call surface-related multiples and internal multiples. Surface-related multiples are those multiples that contain at least one reflection at the earth's surface, whereas internal multiples consist of waves that have reflected only at subsurface interfaces. Surface-related multiples are the strongest, but also relatively easy to deal with because the reflecting boundary (the earth's surface) is known. Internal multiples constitute a much more difficult problem for seismic imaging, because the positions and properties of the reflecting interfaces are not known. We are developing reflection imaging methodology which deals with internal multiples. Starting with the Marchenko equation for 1D inverse scattering problems, we derived 3D Marchenko-type equations, which relate reflection data at the surface to Green's functions between virtual sources anywhere in the subsurface and receivers at the surface. Based on these equations, we derived an iterative scheme by which these Green's functions can be retrieved from the reflection data at the surface. This iterative scheme requires an estimate of the direct wave of the Green's functions in a background medium. Note that this is precisely the same information that is also required by standard reflection imaging schemes. However, unlike in standard imaging, our iterative Marchenko scheme retrieves the multiple reflections of the Green's functions from the reflection data at the surface. For this, no knowledge of the positions and properties of the reflecting interfaces is required. Once the full Green's functions are retrieved, reflection imaging can be carried out by which the primaries and multiples are mapped to their correct positions, with correct reflection amplitudes. In the presentation we will illustrate this new methodology with numerical examples and discuss its potential and limitations.
Carrillo, Maria C; Blennow, Kaj; Soares, Holly; Lewczuk, Piotr; Mattsson, Niklas; Oberoi, Pankaj; Umek, Robert; Vandijck, Manu; Salamone, Salvatore; Bittner, Tobias; Shaw, Leslie M; Stephenson, Diane; Bain, Lisa; Zetterberg, Henrik
2013-03-01
Recognizing that international collaboration is critical for the acceleration of biomarker standardization efforts and the efficient development of improved diagnosis and therapy, the Alzheimer's Association created the Global Biomarkers Standardization Consortium (GBSC) in 2010. The consortium brings together representatives of academic centers, industry, and the regulatory community with the common goal of developing internationally accepted common reference standards and reference methods for the assessment of cerebrospinal fluid (CSF) amyloid β42 (Aβ42) and tau biomarkers. Such standards are essential to ensure that analytical measurements are reproducible and consistent across multiple laboratories and across multiple kit manufacturers. Analytical harmonization for CSF Aβ42 and tau will help reduce confusion in the AD community regarding the absolute values associated with the clinical interpretation of CSF biomarker results and enable worldwide comparison of CSF biomarker results across AD clinical studies. Copyright © 2013 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.
Prentice, Boone M; Chumbley, Chad W; Hachey, Brian C; Norris, Jeremy L; Caprioli, Richard M
2016-10-04
Quantitative matrix-assisted laser desorption/ionization time-of-flight (MALDI TOF) approaches have historically suffered from poor accuracy and precision mainly due to the nonuniform distribution of matrix and analyte across the target surface, matrix interferences, and ionization suppression. Tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity as well as improve signal-to-noise ratios by eliminating interferences from chemical noise, alleviating some concerns about dynamic range. However, conventional MALDI TOF/TOF modalities typically only scan for a single MS/MS event per laser shot, and multiplex assays require sequential analyses. We describe here new methodology that allows for multiple TOF/TOF fragmentation events to be performed in a single laser shot. This technology allows the reference of analyte intensity to that of the internal standard in each laser shot, even when the analyte and internal standard are quite disparate in m/z, thereby improving quantification while maintaining chemical specificity and duty cycle. In the quantitative analysis of the drug enalapril in pooled human plasma with ramipril as an internal standard, a greater than 4-fold improvement in relative standard deviation (<10%) was observed as well as improved coefficients of determination (R 2 ) and accuracy (>85% quality controls). Using this approach we have also performed simultaneous quantitative analysis of three drugs (promethazine, enalapril, and verapamil) using deuterated analogues of these drugs as internal standards.
USDA-ARS?s Scientific Manuscript database
Microsatellite markers (MS) have traditionally been used for parental verification and are still the international standard in spite of their higher cost, error rate, and turnaround time compared with Single Nucleotide Polymorphisms (SNP)-based assays. Despite domestic and international demands fro...
Cheng, Dongwan; Zheng, Li; Hou, Junjie; Wang, Jifeng; Xue, Peng; Yang, Fuquan; Xu, Tao
2015-01-01
The absolute quantification of target proteins in proteomics involves stable isotope dilution coupled with multiple reactions monitoring mass spectrometry (SID-MRM-MS). The successful preparation of stable isotope-labeled internal standard peptides is an important prerequisite for the SID-MRM absolute quantification methods. Dimethyl labeling has been widely used in relative quantitative proteomics and it is fast, simple, reliable, cost-effective, and applicable to any protein sample, making it an ideal candidate method for the preparation of stable isotope-labeled internal standards. MRM mass spectrometry is of high sensitivity, specificity, and throughput characteristics and can quantify multiple proteins simultaneously, including low-abundance proteins in precious samples such as pancreatic islets. In this study, a new method for the absolute quantification of three proteases involved in insulin maturation, namely PC1/3, PC2 and CPE, was developed by coupling a stable isotope dimethyl labeling strategy for internal standard peptide preparation with SID-MRM-MS quantitative technology. This method offers a new and effective approach for deep understanding of the functional status of pancreatic β cells and pathogenesis in diabetes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, George; Haring, Adrian; Spooner, Ted
To help address the industry's needs for assuring the value and reducing the risk of investments in PV power plants; the International Electrotechnical Commission (IEC) has established a new conformity assessment system for renewable energy (IECRE). There are presently important efforts underway to define the requirements for various types of PV system certificates, and publication of the international standards upon which these certifications will be based. This paper presents a detailed analysis of the interrelationship of these activities and the timing for initiation of IECRE PV system certifications.
USDA-ARS?s Scientific Manuscript database
Microsatellite markers (MS) have traditionally been used for parental verification and are still the international standard in spite of their higher cost, error rate, and turnaround time compared with Single Nucleotide Polymorphisms (SNP) -based assays. Despite domestic and international demands fr...
International standards for brucellosis prevention and management.
Ragan, V; Vroegindewey, G; Babcock, S
2013-04-01
International standards are a crucial element in brucellosis prevention and management. They allow policy-makers, scientists, epidemiologists, laboratories and trade entities to have a common vocabulary for communication and understanding of the disease. These standards cover the entire spectrum of activities from surveillance, testing, prophylaxis, transport and trade to policy development, research and reporting. Developing, adhering to and monitoring standards increases both the effectiveness and efficiency of prevention and management programmes. Creating standards with the input of all stakeholders ensures that the standards do not adversely affect the requirements of any of the multiple parties involved. The World Organisation for Animal Health (OIE), in conjunction with its Member Countries, and through its standing and ad hoc committees plus expert input, has taken a key leadership role in developing and reviewing brucellosis standards. These standards are used to harmonise testing, prevention processes, vaccines and reporting, to support trade and to protect human and animal health.
Adamec, Jiri; Yang, Wen-Chu; Regnier, Fred E
2014-01-14
Reagents and methods are provided that permit simultaneous analysis of multiple diverse small molecule analytes present in a complex mixture. Samples are labeled with chemically identical but isotopically distince forms of the labeling reagent, and analyzed using mass spectrometry. A single reagent simultaneously derivatizes multiple small molecule analytes having different reactive functional groups.
ERIC Educational Resources Information Center
Paletta, Angelo
2014-01-01
This article investigates the effect of school autonomy on multiple measures of student achievement, combining the individual data of the students participating in the International Civics and Citizenship Survey with their results in the national high stakes standardized tests at the end of eighth grade administered by the Italian National…
ERIC Educational Resources Information Center
Wilkerson, Judy R.
2017-01-01
Purpose: Understanding and navigating the differences in standards, and the roots and rationales underlying accreditation reviews, is necessary for all institutions that seek multiple accreditations. The purpose of this paper is to demonstrate a method to assist institutional-level leaders and assessment practitioners analyze and align these…
Cantrill, Richard C
2008-01-01
Methods of analysis for products of modern biotechnology are required for national and international trade in seeds, grain and food in order to meet the labeling or import/export requirements of different nations and trading blocks. Although many methods were developed by the originators of transgenic events, governments, universities, and testing laboratories, trade is less complicated if there exists a set of international consensus-derived analytical standards. In any analytical situation, multiple methods may exist for testing for the same analyte. These methods may be supported by regional preferences and regulatory requirements. However, tests need to be sensitive enough to determine low levels of these traits in commodity grain for regulatory purposes and also to indicate purity of seeds containing these traits. The International Organization for Standardization (ISO) and its European counterpart have worked to produce a suite of standards through open, balanced and consensus-driven processes. Presently, these standards are approaching the time for their first review. In fact, ISO 21572, the "protein standard" has already been circulated for systematic review. In order to expedite the review and revision of the nucleic acid standards an ISO Technical Specification (ISO/TS 21098) was drafted to set the criteria for the inclusion of precision data from collaborative studies into the annexes of these standards.
Conway, Kristin M; Ciafaloni, Emma; Matthews, Dennis; Westfield, Chris; James, Kathy; Paramsothy, Pangaja; Romitti, Paul A
2018-07-01
Duchenne and Becker muscular dystrophies, collectively referred to as dystrophinopathies, are X-linked recessive diseases that affect dystrophin production resulting in compromised muscle function across multiple systems. The International Classification of Functioning, Disability and Health provides a systematic classification scheme from which body functions affected by a dystrophinopathy can be identified and used to examine functional health. The infrastructure of the Muscular Dystrophy Surveillance, Tracking, and Research Network was used to identify commonly affected body functions and link selected functions to clinical surveillance data collected through medical record abstraction. Seventy-one (24 second-, 41 third- and 7 fourth-level) body function categories were selected via clinician review and consensus. Of these, 15 of 24 retained second-level categories were linked to data elements from the Muscular Dystrophy Surveillance, Tracking, and Research Network surveillance database. Our findings support continued development of a core set of body functions from the International Classification of Functioning, Disability and Health system that are representative of disease progression in dystrophinopathies and the incorporation of these functions in standardized evaluations of functional health and implementation of individualized rehabilitation care plans. Implications for Rehabilitation Duchenne and Becker muscular dystrophies, collectively referred to as dystrophinopathies, are X-linked recessive disorders that affect the production of dystrophin resulting in compromised muscle function across multiple systems. The severity and progressive nature of dystrophinopathies can have considerable impact on a patient's participation in activities across multiple life domains. Our findings support continued development of an International Classification of Functioning, Disability and Health core set for childhood-onset dystrophinopathies. A standardized dystrophinopathy International Classification of Functioning, Disability and Health documentation form can be used as a screening tool by rehabilitation professionals and for patient goal setting when developing rehabilitation plans. Patient reports of perceived functional health should be incorporated into the rehabilitation plan and therapeutic progress monitored by a standardized form.
Brief International Cognitive Assessment for MS (BICAMS): international standards for validation.
Benedict, Ralph H B; Amato, Maria Pia; Boringa, Jan; Brochet, Bruno; Foley, Fred; Fredrikson, Stan; Hamalainen, Paivi; Hartung, Hans; Krupp, Lauren; Penner, Iris; Reder, Anthony T; Langdon, Dawn
2012-07-16
An international expert consensus committee recently recommended a brief battery of tests for cognitive evaluation in multiple sclerosis. The Brief International Cognitive Assessment for MS (BICAMS) battery includes tests of mental processing speed and memory. Recognizing that resources for validation will vary internationally, the committee identified validation priorities, to facilitate international acceptance of BICAMS. Practical matters pertaining to implementation across different languages and countries were discussed. Five steps to achieve optimal psychometric validation were proposed. In Step 1, test stimuli should be standardized for the target culture or language under consideration. In Step 2, examiner instructions must be standardized and translated, including all information from manuals necessary for administration and interpretation. In Step 3, samples of at least 65 healthy persons should be studied for normalization, matched to patients on demographics such as age, gender and education. The objective of Step 4 is test-retest reliability, which can be investigated in a small sample of MS and/or healthy volunteers over 1-3 weeks. Finally, in Step 5, criterion validity should be established by comparing MS and healthy controls. At this time, preliminary studies are underway in a number of countries as we move forward with this international assessment tool for cognition in MS.
Krasnodebski, Marcin
2016-11-01
Turpentine is a complex substance of pine resin origin, widely used as a solvent in multiple industries. Attempts to define it, even when elaborated by scientists, have been marked by a whole range of extra-scientific market considerations. While the Pine Institute, a resin chemistry research centre in Bordeaux, succeeded in stabilizing the meaning of the word "turpentine" on the national level in France, its expertise was contested abroad. When the International Organization for Standardization (ISO) Committee 35 tried to establish a new international standard for turpentine, France was accused of protecting its industry by twisting scientific definitions for its own needs. The ISO members clashed over the relationship between trade standards and scientific definitions, at the same time highlighting the epistemological difficulties in constructing both categories.
Recent progress in the development of ISO 19751
NASA Astrophysics Data System (ADS)
Farnand, Susan P.; Dalal, Edul N.; Ng, Yee S.
2006-01-01
A small number of general visual attributes have been recognized as essential in describing image quality. These include micro-uniformity, macro-uniformity, colour rendition, text and line quality, gloss, sharpness, and spatial adjacency or temporal adjacency attributes. The multiple-part International Standard discussed here was initiated by the INCITS W1 committee on the standardization of office equipment to address the need for unambiguously documented procedures and methods, which are widely applicable over the multiple printing technologies employed in office applications, for the appearance-based evaluation of these visually significant image quality attributes of printed image quality. 1,2 The resulting proposed International Standard, for which ISO/IEC WD 19751-1 3 presents an overview and an outline of the overall procedure and common methods, is based on a proposal that was predicated on the idea that image quality could be described by a small set of broad-based attributes. 4 Five ad hoc teams were established (now six since a sharpness team is in the process of being formed) to generate standards for one or more of these image quality attributes. Updates on the colour rendition, text and line quality, and gloss attributes are provided.
Joyce, Barbara L; Steenbergh, Timothy; Scher, Eric
2010-06-01
This study examined the psychometric properties of the Kalamazoo Essential Elements Communication Checklist (Adapted) (KEECC-A), which addresses 7 key elements of physician communication identified in the Kalamazoo Consensus Statement, in a sample of 135 residents in multiple specialties at a large urban medical center in 2008-2009. The KEECC-A was used by residents, standardized patients, and faculty as the assessment tool in a broader institutional curriculum initiative. Three separate KEECC-A scores (self-ratings, faculty ratings, and standardized patient ratings) were calculated for each resident to assess the internal consistency and factor structure of the checklist. In addition, we analyzed KEECC-A ratings by gender and US versus international medical graduates, and collected American Board of Internal Medicine Patient Satisfaction Questionnaire (PSQ) scores for a subsample of internal medicine residents (n = 28) to examine the relationship between this measure and the KEECC-A ratings to provide evidence of convergent validity. The KEECC-A ratings generated by faculty, standardized patients, and the residents themselves demonstrated a high degree of internal consistency. Factor analyses of the 3 different sets of KEECC-A ratings produced a consistent single-factor structure. We could not examine the relationship between KEECC-A and the PSQ because of substantial range restriction in PSQ scores. No differences were seen in the communication scores of men versus women. Faculty rated US graduates significantly higher than international medical graduates. Our study provides evidence for the reliability and validity of the KEECC-A as a measure of physician communication skills. The KEECC-A appears to be a psychometrically sound, user-friendly communication tool, linked to an expert consensus statement, that can be quickly and accurately completed by multiple raters across diverse specialties.
Inhibitory control in young children and its role in emerging internalization.
Kochanska, G; Murray, K; Jacques, T Y; Koenig, A L; Vandegeest, K A
1996-04-01
We examined inhibitory control as a quality of temperament that contributes to internalization. Children were assessed twice, at 26-41 months (N = 103) and at 43-56 months (N = 99), on repeated occasions, in multiple observational contexts and using parental reports. Comprehensive behavioral batteries incorporating multiple tasks were designed to measure inhibitory control at toddler and preschool age. They had good internal consistencies, corresponded with maternal ratings, and were developmentally sensitive. Individual children's performance was significantly correlated across both assessments, indicating stable individual differences. Girls surpassed boys at both ages. Children's internalization was observed while they were alone with prohibited objects, with a mundane chore, playing games that occasioned cheating, being induced to violate standards of conduct, and assessed using maternal reports. Inhibitory control was significantly associated with internalization, both contemporaneously and as a predictor in the longitudinal sense. The implications for considering children's temperament as a significant, yet often neglected contributor to developing internalization are discussed.
NASA Astrophysics Data System (ADS)
Thornton, P. E.; Nacp Site Synthesis Participants
2010-12-01
The North American Carbon Program (NACP) synthesis effort includes an extensive intercomparison of modeled and observed ecosystem states and fluxes preformed with multiple models across multiple sites. The participating models span a range of complexity and intended application, while the participating sites cover a broad range of natural and managed ecosystems in North America, from the subtropics to arctic tundra, and coastal to interior climates. A unique characteristic of this collaborative effort is that multiple independent observations are available at all sites: fluxes are measured with the eddy covariance technique, and standard biometric and field sampling methods provide estimates of standing stock and annual production in multiple categories. In addition, multiple modeling approaches are employed to make predictions at each site, varying, for example, in the use of diagnostic vs. prognostic leaf area index. Given multiple independent observational constraints and multiple classes of model, we evaluate the internal consistency of observations at each site, and use this information to extend previously derived estimates of uncertainty in the flux observations. Model results are then compared with all available observations and models are ranked according to their consistency with each type of observation (high frequency flux measurement, carbon stock, annual production). We demonstrate a range of internal consistency across the sites, and show that some models which perform well against one observational metric perform poorly against others. We use this analysis to construct a hypothesis for combining eddy covariance, biometrics, and other standard physiological and ecological measurements which, as data collection proceeded over several years, would present an increasingly challenging target for next generation models.
CAD/CAE Integration Enhanced by New CAD Services Standard
NASA Technical Reports Server (NTRS)
Claus, Russell W.
2002-01-01
A Government-industry team led by the NASA Glenn Research Center has developed a computer interface standard for accessing data from computer-aided design (CAD) systems. The Object Management Group, an international computer standards organization, has adopted this CAD services standard. The new standard allows software (e.g., computer-aided engineering (CAE) and computer-aided manufacturing software to access multiple CAD systems through one programming interface. The interface is built on top of a distributed computing system called the Common Object Request Broker Architecture (CORBA). CORBA allows the CAD services software to operate in a distributed, heterogeneous computing environment.
Bridging the gap between financial reporting and the revenue cycle.
Clark, Kari; Bang, Derek A
2012-09-01
Implementing a standardized financial reporting and revenue cycle monitoring platform can help healthcare organizations improve their net revenue reporting and budgeting processes. Consistent, standardized data help the finance office estimate accounts receivable reserves more accurately, streamline the month-end closing process, and strengthen internal controls. The benefits of standardizing the finance and revenue cycle functions are particularly significant in large organizations with multiple facilities, but even single-facility providers can benefit from improved communication between the business office and finance.
Linearized inversion of multiple scattering seismic energy
NASA Astrophysics Data System (ADS)
Aldawood, Ali; Hoteit, Ibrahim; Zuberi, Mohammad
2014-05-01
Internal multiples deteriorate the quality of the migrated image obtained conventionally by imaging single scattering energy. So, imaging seismic data with the single-scattering assumption does not locate multiple bounces events in their actual subsurface positions. However, imaging internal multiples properly has the potential to enhance the migrated image because they illuminate zones in the subsurface that are poorly illuminated by single scattering energy such as nearly vertical faults. Standard migration of these multiples provides subsurface reflectivity distributions with low spatial resolution and migration artifacts due to the limited recording aperture, coarse sources and receivers sampling, and the band-limited nature of the source wavelet. The resultant image obtained by the adjoint operator is a smoothed depiction of the true subsurface reflectivity model and is heavily masked by migration artifacts and the source wavelet fingerprint that needs to be properly deconvolved. Hence, we proposed a linearized least-square inversion scheme to mitigate the effect of the migration artifacts, enhance the spatial resolution, and provide more accurate amplitude information when imaging internal multiples. The proposed algorithm uses the least-square image based on single-scattering assumption as a constraint to invert for the part of the image that is illuminated by internal scattering energy. Then, we posed the problem of imaging double-scattering energy as a least-square minimization problem that requires solving the normal equation of the following form: GTGv = GTd, (1) where G is a linearized forward modeling operator that predicts double-scattered seismic data. Also, GT is a linearized adjoint operator that image double-scattered seismic data. Gradient-based optimization algorithms solve this linear system. Hence, we used a quasi-Newton optimization technique to find the least-square minimizer. In this approach, an estimate of the Hessian matrix that contains curvature information is modified at every iteration by a low-rank update based on gradient changes at every step. At each iteration, the data residual is imaged using GT to determine the model update. Application of the linearized inversion to synthetic data to image a vertical fault plane demonstrate the effectiveness of this methodology to properly delineate the vertical fault plane and give better amplitude information than the standard migrated image using the adjoint operator that takes into account internal multiples. Thus, least-square imaging of multiple scattering enhances the spatial resolution of the events illuminated by internal scattering energy. It also deconvolves the source signature and helps remove the fingerprint of the acquisition geometry. The final image is obtained by the superposition of the least-square solution based on single scattering assumption and the least-square solution based on double scattering assumption.
Education Outcomes in a Duty-Hour Flexibility Trial in Internal Medicine.
Desai, Sanjay V; Asch, David A; Bellini, Lisa M; Chaiyachati, Krisda H; Liu, Manqing; Sternberg, Alice L; Tonascia, James; Yeager, Alyssa M; Asch, Jeremy M; Katz, Joel T; Basner, Mathias; Bates, David W; Bilimoria, Karl Y; Dinges, David F; Even-Shoshan, Orit; Shade, David M; Silber, Jeffrey H; Small, Dylan S; Volpp, Kevin G; Shea, Judy A
2018-04-19
Concern persists that inflexible duty-hour rules in medical residency programs may adversely affect the training of physicians. We randomly assigned 63 internal medicine residency programs in the United States to be governed by standard duty-hour policies of the 2011 Accreditation Council for Graduate Medical Education (ACGME) or by more flexible policies that did not specify limits on shift length or mandatory time off between shifts. Measures of educational experience included observations of the activities of interns (first-year residents), surveys of trainees (both interns and residents) and faculty, and intern examination scores. There were no significant between-group differences in the mean percentages of time that interns spent in direct patient care and education nor in trainees' perceptions of an appropriate balance between clinical demands and education (primary outcome for trainee satisfaction with education; response rate, 91%) or in the assessments by program directors and faculty of whether trainees' workload exceeded their capacity (primary outcome for faculty satisfaction with education; response rate, 90%). Another survey of interns (response rate, 49%) revealed that those in flexible programs were more likely to report dissatisfaction with multiple aspects of training, including educational quality (odds ratio, 1.67; 95% confidence interval [CI], 1.02 to 2.73) and overall well-being (odds ratio, 2.47; 95% CI, 1.67 to 3.65). In contrast, directors of flexible programs were less likely to report dissatisfaction with multiple educational processes, including time for bedside teaching (response rate, 98%; odds ratio, 0.13; 95% CI, 0.03 to 0.49). Average scores (percent correct answers) on in-training examinations were 68.9% in flexible programs and 69.4% in standard programs; the difference did not meet the noninferiority margin of 2 percentage points (difference, -0.43; 95% CI, -2.38 to 1.52; P=0.06 for noninferiority). od Institute and the ACGME; iCOMPARE ClinicalTrials.gov number, NCT02274818 .). There was no significant difference in the proportion of time that medical interns spent on direct patient care and education between programs with standard duty-hour policies and programs with more flexible policies. Interns in flexible programs were less satisfied with their educational experience than were their peers in standard programs, but program directors were more satisfied. (Funded by the National Heart, Lung, and Blo
Xiang, Yu; Song, Xiaona; Qiao, Jing; Zang, Yimei; Li, Yanpeng; Liu, Yong; Liu, Chunsheng
2015-07-01
An efficient simplified method was developed to determine multiple classes of phytohormones simultaneously in the medicinal plant Glycyrrhiza uralensis. Ultrahigh-performance liquid chromatography electrospray ionization tandem mass spectrometry (UPLC/ESI-MS/MS) with multiple reaction monitoring (MRM) in negative mode was used for quantification. The five studied phytohormones are gibberellic acid (GA3), abscisic acid (ABA), jasmonic acid (JA), indole-3-acetic acid, and salicylic acid (SA). Only 100 mg of fresh leaves was needed, with one purification step based on C18 solid-phase extraction. Cinnamic acid was chosen as the internal standard instead of isotope-labeled internal standards. Under the optimized conditions, the five phytohormones with internal standard were separated within 4 min, with good linearities and high sensitivity. The validated method was applied to monitor the spatial and temporal changes of the five phytohormones in G. uralensis under ABA stress. The levels of GA3, ABA, JA, and SA in leaves of G. uralensis were increased at different times and with different tendencies in the reported stress mode. These changes in phytohormone levels are discussed in the context of a possible feedback regulation mechanism. Understanding this mechanism will provide a good chance of revealing the mutual interplay between different biosynthetic routes, which could further help elucidate the mechanisms of effective composition accumulation in medicinal plants.
Lin, Yi-Reng; Huang, Mei-Fang; Wu, You-Ying; Liu, Meng-Chieh; Huang, Jing-Heng; Chen, Ziyu; Shiue, Yow-Ling; Wu, Chia-En; Liang, Shih-Shin
2017-09-01
In this work, we synthesized internal standards for four garlic organosulfur compounds (OSCs) by reductive amination with 13 C, D 2 -formaldehyde, and developed an isotope dilution analysis method to quantitate these organosulfur components in garlic samples. Internal standards were synthesized for internal absolute quantification of S-allylcysteine (SAC), S-allylcysteine sulfoxide (alliin), S-methylcysteine (SMC), and S-ethylcysteine (SEC). We used a multiple reaction monitoring (MRM) to detect 13 C, D 2 -formaldehyde-modified OSCs by ultrahigh-performance liquid phase chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) and obtained MS spectra showing different ratios of 13 C, D 2 -formaldehyde-modified and H 2 -formaldehyde-modified compounds. The resulting labeled and unlabeled OSCs were exhibited correlation coefficient (R 2 ) ranged from 0.9989 to 0.9994, respectively. The average recoveries for four OSCs at three concentration levels ranged from 89% to 105%. By 13 C, D 2 -formaldehyde and sodium cyanoborohydride, the reductive amination-based method can be utilized to generate novel internal standard for isotope dilution and to extend the quantitative application. Copyright © 2017 Elsevier Ltd. All rights reserved.
International aircrew sleep and wakefulness after multiple time zone flights - A cooperative study
NASA Technical Reports Server (NTRS)
Graeber, R. Curtis; Lauber, John K.; Connell, Linda J.; Gander, Philippa H.
1986-01-01
An international research team has carried out an electroencephalographic study of sleep and wakefulness in flight crews operating long-haul routes across seven or eight time zones. Following baseline recordings, volunteer crews (n = 56) from four airlines spent their first outbound layover at a sleep laboratory. This paper provides an overview of the project's history, its research design, and the standardization of procedures. The overall results are remarkably consistent among the four participating laboratories and strongly support the feasibility of cooperative international sleep research in the operational arena.
Sociocultural Variations in the Body Image Perceptions of Urban Adolescent Females.
ERIC Educational Resources Information Center
Abrams, Laura S.; Stormer, Colleen Cook
2002-01-01
Investigated the influences of ethnicity, socioeconomic status, and ethnic peer group composition on awareness and internalization of socially sanctioned standards of appearance using the Sociocultural Attitudes towards Adolescence Questionnaire. Findings for 208 adolescent females highlight the importance of multiple ecological factors in…
Smartcards in Libraries: A Brave New World.
ERIC Educational Resources Information Center
Myhill, Martin
1998-01-01
Describes the University of Exeter (UK), Mondex, and NatWest UK smartcard-based campus card system project. Smartcards, wallet-sized plastic cards with microprocessors, interface with network terminal devices and are programmable as data, identity, and finance cards. International standard multiple operating system (MULTOS) increases current…
Nirogi, Ramakrishna V S; Kandikere, Vishwottam N; Mudigonda, Koteshwara; Maurya, Santosh
2007-02-01
A simple, rapid, sensitive, and selective liquid chromatography-tandem mass spectrometry method is developed and validated for the quantitation of galantamine, an acetylcholinesterase inhibitor in human plasma, using a commercially available compound, loratadine, as the internal standard. Following liquid-liquid extraction, the analytes are separated using an isocratic mobile phase on a reverse-phase C18 column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective (M+H)+ ions, m/z 288 to 213 for galantamine and m/z 383 and 337 for the internal standard. The assay exhibit a linear dynamic range of 0.5-100 ng/mL for galantamine in human plasma. The lower limit of quantitation is 0.5 ng/mL, with a relative standard deviation of less than 8%. Acceptable precision and accuracy are obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample makes it possible to analyze more than 400 human plasma samples per day. The validated method is successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability, or bioequivalence studies.
2017-01-01
Background Clinicians, such as respiratory therapists and physicians, are often required to set up pieces of medical equipment that use inconsistent terminology. Current lung ventilator terminology that is used by different manufacturers contributes to the risk of usage errors, and in turn the risk of ventilator-associated lung injuries and other conditions. Human factors and communication issues are often associated with ventilator-related sentinel events, and inconsistent ventilator terminology compounds these issues. This paper describes our proposed protocol, which will be implemented at the University of Waterloo, Canada when this project is externally funded. Objective We propose to determine whether a standardized vocabulary improves the ease of use, safety, and utility as it relates to the usability of medical devices, compared to legacy medical devices from multiple manufacturers, which use different terms. Methods We hypothesize that usage errors by clinicians will be lower when standardization is consistently applied by all manufacturers. The proposed study will experimentally examine the impact of standardized nomenclature on performance declines in the use of an unfamiliar ventilator product in clinically relevant scenarios. Participants will be respiratory therapy practitioners and trainees, and we propose studying approximately 60 participants. Results The work reported here is in the proposal phase. Once the protocol is implemented, we will report the results in a follow-up paper. Conclusions The proposed study will help us better understand the effects of standardization on medical device usability. The study will also help identify any terms in the International Organization for Standardization (ISO) Draft International Standard (DIS) 19223 that may be associated with recurrent errors. Amendments to the standard will be proposed if recurrent errors are identified. This report contributes a protocol that can be used to assess the effect of standardization in any given domain that involves equipment, multiple manufacturers, inconsistent vocabulary, symbology, audio tones, or patterns in interface navigation. Second, the protocol can be used to experimentally evaluate the ISO DIS 19223 for its effectiveness, as researchers around the world may wish to conduct such tests and compare results. PMID:28887292
Internationalizing Technology Teaching with Blogs and Bananas
ERIC Educational Resources Information Center
Davey, Sandy; Smith, Walter S.; Merrill, Chris
2009-01-01
Educators can connect their students internationally in meaningful activities that address multiple teaching standards that are of concern to educators, parents, and the public worldwide. In this article, the authors describe a project wherein Australian Year 7 students made an "Edible Lunar Vehicle" (ELV) together with U.S. college…
ERIC Educational Resources Information Center
Witzig, Stephen B.; Rebello, Carina M.; Siegel, Marcelle A.; Freyermuth, Sharyn K.; Izci, Kemal; McClure, Bruce
2014-01-01
Identifying students' conceptual scientific understanding is difficult if the appropriate tools are not available for educators. Concept inventories have become a popular tool to assess student understanding; however, traditionally, they are multiple choice tests. International science education standard documents advocate that assessments…
Cascading Effects of BPT for Child Internalizing Problems and Caregiver Depression
Gonzalez, Michelle A.; Jones, Deborah J.
2016-01-01
Behavioral Parent Training (BPT) is the standard of care for early onset (3 to 8 years old) disruptive behavior disorders (DBDs). Preliminary evidence suggests that BPT may also produce cascading treatment effects for comorbid and interrelated symptomatology in children, primarily internalizing problems, as well as symptomatology in multiple systems of the family, including caregiver depressive symptomatology. What is less well understood, however, is why and how BPT functions to impact these multiple symptom clusters within and between family members. Accordingly, this manuscript aims to serve as a conceptual and theoretical consideration of the mechanisms through which BPT may produce generalized treatment effects among children with early onset DBDs and internalizing problems, as well as the psychosocial difficulties among their caregivers. It is our intention that the hypothesized mechanisms highlighted in this review may guide advances in clinical research, as well as assessment and practice. PMID:27676702
Hopewell, Philip C; Fair, Elizabeth L; Uplekar, Mukund
2014-03-01
The International Standards for Tuberculosis Care, first published in 2006 (Lancet Infect Dis 2006;6:710-725.) with a second edition in 2009 ( www.currytbcenter.ucsf.edu/international/istc_report ), was produced by an international coalition of organizations funded by the United States Agency for International Development. Development of the document was led jointly by the World Health Organization and the American Thoracic Society, with the aim of promoting engagement of all care providers, especially those in the private sector in low- and middle-income countries, in delivering high-quality services for tuberculosis. In keeping with World Health Organization recommendations regarding rapid molecular testing, as well as other pertinent new recommendations, the third edition of the Standards has been developed. After decades of dormancy, the technology available for tuberculosis care and control is now rapidly evolving. In particular, rapid molecular testing, using devices with excellent performance characteristics for detecting Mycobacterium tuberculosis and rifampin resistance, and that are practical and affordable for use in decentralized facilities in low-resource settings, is being widely deployed globally. Used appropriately, both within tuberculosis control programs and in private laboratories, these devices have the potential to revolutionize tuberculosis care and control, providing a confirmed diagnosis and a determination of rifampin resistance within a few hours, enabling appropriate treatment to be initiated promptly. Major changes have been made in the standards for diagnosis. Additional important changes include: emphasis on the recognition of groups at increased risk of tuberculosis; updating the standard on antiretroviral treatment in persons with tuberculosis and human immunodeficiency virus infection; and revising the standard on treating multiple drug-resistant tuberculosis.
Business Management System Support Analysis
NASA Technical Reports Server (NTRS)
Parikh, Jay
2008-01-01
The purpose of this research project was to develop a searchable database compiled with internal and external audit findings/observations. The data will correspond to the findings and observations from the date of Center-wide implementation of the ISO 9001-2000 standard to the present (2003-2008). It was derived and extracted from several sources and was in multiple formats. Once extracted, categorization of the findings/observations would be possible. The final data was mapped to the ISO 9001-2000 standard with the understanding that it will be displayed graphically. The data will be used to verify trends, associate risks, and establish timelines to identify strengths and weaknesses to determine areas of improvement in the Kennedy Space Center Business Management System Internal Audit Program.
Austin, Paul F; Bauer, Stuart B; Bower, Wendy; Chase, Janet; Franco, Israel; Hoebeke, Piet; Rittig, Søren; Walle, Johan Vande; von Gontard, Alexander; Wright, Anne; Yang, Stephen S; Nevéus, Tryggve
2016-04-01
The impact of the original International Children's Continence Society (ICCS) terminology document on lower urinary tract (LUT) function resulted in the global establishment of uniformity and clarity in the characterization of LUT function and dysfunction in children across multiple healthcare disciplines. The present document serves as a stand-alone terminology update reflecting refinement and current advancement of knowledge on pediatric LUT function. A variety of worldwide experts from multiple disciplines within the ICCS leadership who care for children with LUT dysfunction were assembled as part of the standardization committee. A critical review of the previous ICCS terminology document and the current literature was performed. Additionally, contributions and feedback from the multidisciplinary ICCS membership were solicited. Following a review of the literature over the last 7 years, the ICCS experts assembled a new terminology document reflecting current understanding of bladder function and LUT dysfunction in children using the resources from the literature review, expert opinion and ICCS member feedback. The present ICCS terminology document provides a current and consensus update to the evolving terminology and understanding of LUT function in children. Neurourol. Urodynam. 35:471-481, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Moving beyond the Name: Defining Corporate Entities to Support Provenance-Based Access
ERIC Educational Resources Information Center
Light, Michelle
2007-01-01
The second edition of the "International Standard Archival Authority Records for Corporate Bodies, Persons, and Families (ISAAR(CPF)2)" focuses on describing entities as they exist in reality, rather than on establishing authorized terms. This change allows authority records to include multiple authorized terms representing an entity as it changed…
Introduction to ISO 15189: a blueprint for quality systems in veterinary laboratories.
Freeman, Kathleen P; Bauer, Natali; Jensen, Asger L; Thoresen, Stein
2006-06-01
A trend in human and veterinary medical laboratory management is to achieve accreditation based on international standards. The International Organization for Standardization (ISO) 15189 standard is the first developed especially for accreditation of medical laboratories, and emphasizes the laboratory-client interface. European veterinary laboratories seeking to train candidates for the certification examination of the European College of Veterinary Clinical Pathology (ECVCP) require approval by the ECVCP Laboratory Standards Committee, which bases its evaluation in part on adherence to quality systems described in the ISO 15189 standards. The purpose of this article was to introduce the latest ISO quality standard and describe its application to veterinary laboratories in Europe, specifically as pertains to accreditation of laboratories involved in training veterinary clinical pathologists. Between 2003 and 2006, the Laboratory Standards Committee reviewed 12 applications from laboratories (3 commercial and 9 university) involved in training veterinary clinical pathologists. Applicants were asked to provide a description of the facilities for training and testing, current methodology and technology, health and safety policy, quality assurance policy (including internal quality control and participation in an external quality assurance program), written standard operating procedures (SOPs) and policies, a description of the laboratory information system, and personnel and training. Also during this time period multiple informal and formal discussions among ECVCP diplomates took place as to current practices and perceived areas of concern with regard to laboratory accreditation requirements. Areas in which improvement most often was needed in veterinary laboratories applying for ECVCP accreditation were the written quality plan, defined quality requirements for the tests performed, written SOPs and policies, training records, ongoing audits and competency assessments, and processes for identifying and addressing opportunities for improvement. Recommendations were developed for a stepwise approach towards achieving ISO 15189 standards, including 3 levels of quality components. The ISO 15189 standard provides a sound framework for veterinary laboratories aspiring to meet international quality standards.
Large-scale progenitor cell expansion for multiple donors in a monitored hollow fibre bioreactor.
Lambrechts, Toon; Papantoniou, Ioannis; Rice, Brent; Schrooten, Jan; Luyten, Frank P; Aerts, Jean-Marie
2016-09-01
With the increasing scale in stem cell production, a robust and controlled cell expansion process becomes essential for the clinical application of cell-based therapies. The objective of this work was the assessment of a hollow fiber bioreactor (Quantum Cell Expansion System from Terumo BCT) as a cell production unit for the clinical-scale production of human periosteum derived stem cells (hPDCs). We aimed to demonstrate comparability of bioreactor production to standard culture flask production based on a product characterization in line with the International Society of Cell Therapy in vitro benchmarks and supplemented with a compelling quantitative in vivo bone-forming potency assay. Multiple process read-outs were implemented to track process performance and deal with donor-to-donor-related variation in nutrient needs and harvest timing. The data show that the hollow fiber bioreactor is capable of robustly expanding autologous hPDCs on a clinical scale (yield between 316 million and 444 million cells starting from 20 million after ± 8 days of culture) while maintaining their in vitro quality attributes compared with the standard flask-based culture. The in vivo bone-forming assay on average resulted in 10.3 ± 3.7% and 11.0 ± 3.8% newly formed bone for the bioreactor and standard culture flask respectively. The analysis showed that the Quantum system provides a reproducible cell expansion process in terms of yields and culture conditions for multiple donors. Copyright © 2016 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.
International Metadata Standards and Enterprise Data Quality Metadata Systems
NASA Technical Reports Server (NTRS)
Habermann, Ted
2016-01-01
Well-documented data quality is critical in situations where scientists and decision-makers need to combine multiple datasets from different disciplines and collection systems to address scientific questions or difficult decisions. Standardized data quality metadata could be very helpful in these situations. Many efforts at developing data quality standards falter because of the diversity of approaches to measuring and reporting data quality. The one size fits all paradigm does not generally work well in this situation. I will describe these and other capabilities of ISO 19157 with examples of how they are being used to describe data quality across the NASA EOS Enterprise and also compare these approaches with other standards.
[Experts consensus of dental esthetic photography].
2017-05-09
Clinical photography in esthetic dentistry is an essential skill in clinical practice. It is widely applied clinically in multiple fields related to esthetic dentistry. Society of Esthetic Dentistry of Chinese Stomatological Association established a consensus for clinical photography and standards for images in esthetic dentistry in order to standardize domestic dental practitioners' procedure, and meet the demands of diagnosis and design in modern esthetic dentistry. It was also developed to facilitate domestic and international academic communication. Sixteen commonly used images in practice, which are of apparent importance in guiding esthetic analysis, design and implementation, are proposed in the standards. This consensus states the clinical significance of these images and the standard protocol of acquiring them.
Furlong, Michael; Bessire, Andrew; Song, Wei; Huntington, Christopher; Groeber, Elizabeth
2010-07-15
During routine liquid chromatography/tandem mass spectrometric (LC/MS/MS) bioanalysis of a small molecule analyte in rat serum samples from a toxicokinetic study, an unexpected interfering peak was observed in the extracted ion chromatogram of the internal standard. No interfering peaks were observed in the extracted ion chromatogram of the analyte. The dose-dependent peak area response and peak area response versus time profiles of the interfering peak suggested that it might have been related to a metabolite of the dosed compound. Further investigation using high-resolution mass spectrometry led to unequivocal identification of the interfering peak as an N-desmethyl metabolite of the parent analyte. High-resolution mass spectrometry (HRMS) was also used to demonstrate that the interfering response of the metabolite in the multiple reaction monitoring (MRM) channel of the internal standard was due to an isobaric relationship between the (13)C-isotope of the metabolite and the internal standard (i.e., common precursor ion mass), coupled with a metabolite product ion with identical mass to the product ion used in the MRM transition of the internal standard. These results emphasize (1) the need to carefully evaluate internal standard candidates with regard to potential interferences from metabolites during LC/MS/MS method development, validation and bioanalysis of small molecule analytes in biological matrices; (2) the value of HRMS as a tool to investigate unexpected interferences encountered during LC/MS/MS analysis of small molecules in biological matrices; and (3) the potential for interference regardless of choice of IS and therefore the importance of conducting assay robustness on incurred in vitro or in vivo study samples. Copyright 2010 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Journal of College Student Psychotherapy, 2011
2011-01-01
University and college counseling services have played a vital role in higher education for many years. In the last 40 years, there has been a dramatic increase in the number of campus counseling services and the multiplicity of functions that are performed. Guidelines for university and college counseling services were first developed in 1970 by…
77 FR 26238 - Fisheries of the United States; National Standard 1 Guidelines
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-03
... this work, a number of issues regarding the application of the NS1 Guidelines were identified that may.... Further guidance on how OY should be specified to balance the multiple considerations in mixed-stock.... Under the MSA, stocks that have a life cycle of approximately 1 year and stocks subject to international...
NASA Astrophysics Data System (ADS)
Liliawati, W.; Utama, J. A.; Ramalis, T. R.; Rochman, A. A.
2018-03-01
Validation of the Earth and Space Science learning the material in the chapter of the Earth's Protector based on experts (media & content expert and practitioners) and junior high school students' responses are presented. The data came from the development phase of the 4D method (Define, Design, Develop, Dissemination) which consist of two steps: expert appraisal and developmental testing. The instrument employed is rubric of suitability among the book contents with multiple intelligences activities, character education, a standard of book assessment, a questionnaires and close procedure. The appropriateness of the book contents with multiple intelligences, character education and standard of book assessment is in a good category. Meanwhile, students who used the book in their learning process gave a highly positive response; the book was easy to be understood. In general, the result of cloze procedure indicates high readability of the book. As our conclusion is the book chapter of the Earth's Protector can be used as a learning material accommodating students’ multiple intelligences and character internalization.
Sun, Xiaohong; Ouyang, Yue; Chu, Jinfang; Yan, Jing; Yu, Yan; Li, Xiaoqiang; Yang, Jun; Yan, Cunyu
2014-04-18
A sensitive and reliable in-advance stable isotope labeling strategy was developed for simultaneous relative quantification of 8 acidic plant hormones in sub-milligram amount of plant materials. Bromocholine bromide (BETA) and its deuterated counterpart D9-BETA were used to in-advance derivatize control and sample extracts individually, which were then combined and subjected to solid-phase extraction (SPE) purification followed by UPLC-MS/MS analysis. Relative quantification of target compounds was obtained by calculation of the peak area ratios of BETA/D9-BETA labeled plant hormones. The in-advance stable isotope labeling strategy realized internal standard-based relative quantification of multiple kinds of plant hormones independent of availability of internal standard of every analyte with enhanced sensitivity of 1-3 orders of magnitude. Meanwhile, the in-advance labeling contributes to higher sample throughput and more reliability. The method was successfully applied to determine 8 plant hormones in 0.8mg DW (dry weight) of seedlings and 4 plant hormones from single seed of Arabidopsis thaliana. The results show the potential of the method in relative quantification of multiple plant hormones in tiny plant tissues or organs, which will advance the knowledge of the crosstalk mechanism of plant hormones. Copyright © 2014 Elsevier B.V. All rights reserved.
Figures of Merit for Lunar Simulants
NASA Technical Reports Server (NTRS)
Slane, Frederick A.; Rickman, Douglas L.
2012-01-01
At an earlier SRR the concept for an international standard on Lunar regolith simulants was presented. The international standard, ISO 10788, Lunar Simulants, has recently been published. This paper presents the final content of the standard. Therefore, we are presenting an update of the following: The collection and analysis of lunar samples from 1969 to present has yielded large amounts of data. Published analyses give some idea of the complex nature of the regolith at all scales, rocks, soils and the smaller particulates commonly referred to as dust. Data recently acquired in support of NASA s simulant effort has markedly increased our knowledge and quantitatively demonstrates that complexity. It is anticipated that future analyses will further add to the known complexity. In an effort to communicate among the diverse technical communities performing research on or research using regolith samples and simulants, a set of Figures of Merit (FoM) have been devised. The objective is to allow consistent and concise comparative communication between researchers from multiple organizations and nations engaged in lunar exploration. This paper describes Figures of Merit in a new international standard for Lunar Simulants. The FoM methodology uses scientific understanding of the lunar samples to formulate parameters which are reproducibly quantifiable. Contaminants and impurities in the samples are also addressed.
Austin, Paul F; Bauer, Stuart B; Bower, Wendy; Chase, Janet; Franco, Israel; Hoebeke, Piet; Rittig, Søren; Vande Walle, Johan; von Gontard, Alexander; Wright, Anne; Yang, Stephen S; Nevéus, Tryggve
2014-06-01
The impact of the original International Children's Continence Society terminology document on lower urinary tract function resulted in the global establishment of uniformity and clarity in the characterization of lower urinary tract function and dysfunction in children across multiple health care disciplines. The present document serves as a stand-alone terminology update reflecting refinement and current advancement of knowledge on pediatric lower urinary tract function. A variety of worldwide experts from multiple disciplines in the ICCS leadership who care for children with lower urinary tract dysfunction were assembled as part of the standardization committee. A critical review of the previous ICCS terminology document and the current literature was performed. In addition, contributions and feedback from the multidisciplinary ICCS membership were solicited. Following a review of the literature during the last 7 years the ICCS experts assembled a new terminology document reflecting the current understanding of bladder function and lower urinary tract dysfunction in children using resources from the literature review, expert opinion and ICCS member feedback. The present ICCS terminology document provides a current and consensus update to the evolving terminology and understanding of lower urinary tract function in children. For the complete document visit http://jurology.com/. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Astuti, Sri Puji
2013-01-01
The primary purpose of this multiple case study is to explore teachers' and learners' perceptions of motivational teaching strategies. The data were obtained from two schools in a small town in West Sumatra, Indonesia; one is from an international standard high school and the other is from a local high school. This study is underpinned by…
International Virtual Observatory System for Water Resources Information
NASA Astrophysics Data System (ADS)
Leinenweber, Lewis; Bermudez, Luis
2013-04-01
Sharing, accessing, and integrating hydrologic and climatic data have been identified as a critical need for some time. The current state of data portals, standards, technologies, activities, and expertise can be leverage to develop an initial operational capability for a virtual observatory system. This system will allow to link observations data with stream networks and models, and to solve semantic inconsistencies among communities. Prototyping a virtual observatory system is an inter-disciplinary, inter-agency and international endeavor. The Open Geospatial Consortium (OGC) within the OGC Interoperability Program provides the process and expertise to run such collaborative effort. The OGC serves as a global forum for the collaboration of developers and users of spatial data products and services, and to advance the development of international standards for geospatial interoperability. The project coordinated by OGC that is advancing an international virtual observatory system for water resources information is called Climatology-Hydrology Information Sharing Pilot, Phase 1 (CHISP-1). It includes observations and forecasts in the U.S. and Canada levering current networks and capabilities. It is designed to support the following use cases: 1) Hydrologic modeling for historical and near-future stream flow and groundwater conditions. Requires the integration of trans-boundary stream flow and groundwater well data, as well as national river networks (US NHD and Canada NHN) from multiple agencies. Emphasis will be on time series data and real-time flood monitoring. 2) Modeling and assessment of nutrient load into the lakes. Requires accessing water-quality data from multiple agencies and integrating with stream flow information for calculating loads. Emphasis on discrete sampled water quality observations, linking those to specific NHD stream reaches and catchments, and additional metadata for sampled data. The key objectives of these use cases are: 1) To link observations data to the stream network, enabling queries of conditions upstream from a given location to return all relevant gages and well locations. This is currently not practical with the data sources available. 2) To bridge differences in semantics across information models and processes used by the various data producers, to improve the hydrologic and water quality modeling capabilities. Other expected benefits to be derived from this project include: - Leverage a large body of existing data holdings and related activities of multiple agencies in the US and Canada. - Influence data and metadata standards used internationally for web-based information sharing, through multiple agency cooperation and OGC standards setting process. - Reduction of procurement risk through partnership-based development of an initial operating capability verses the cost for building a fully operational system using a traditional "waterfall approach". - Identification and clarification of what is possible, and of the key technical and non-technical barriers to continued progress in sharing and integrating hydrologic and climatic information. - Promote understanding and strengthen ties within the hydro-climatic community. This is anticipated to be the first phase of a multi-phase project, with future work on forecasting the hydrologic consequences of extreme weather events, and enabling more sophisticated water quality modeling.
Global Federation of Data Services in Seismology: Extending the Concept to Interdisciplinary Science
NASA Astrophysics Data System (ADS)
Ahern, Tim; Trabant, Chad; Stults, Mike; VanFossen, Mick
2016-04-01
The International Federation of Digital Seismograph Networks (FDSN) sets international standards, formats, and access protocols for global seismology. Recently the availability of an FDSN standard for web services has enabled the development of a federated model of data access. With a growing number of internationally distributed data centers supporting compatible web services the task of federation is now fully realizable. The utility of this approach is already starting to bear fruit in seismology. This presentation will highlight the advances the seismological community has made in the past year towards federated access to seismological data including waveforms, earthquake event catalogs, and metadata describing seismic stations. It will include a discussion of an IRIS Federator as well as an emerging effort to develop an FDSN Federator that will allow seamless access to seismological information across multiple FDSN data centers. As part of the NSF EarthCube initiative as well as the US-European data coordination project (COOPEUS), IRIS and several partners, collectively called GeoWS, have been extending the concept of standard web services to other domains. Our primary partners include Lamont Doherty Earth Observatory (marine geophysics), Caltech (tectonic plate reconstructions), SDSC (hydrology), UNAVCO (geodesy), and Unidata (atmospheric sciences). Additionally, IRIS is working with partners at NOAA's National Centers for Environmental Information (NCEI) , NEON, UTEP, WOVOdat, INTERMAGNET, Global Geodynamics Program, and the Ocean Observatory Initiative (OOI) to develop web services for those domains. The ultimate goal is to allow discovery, access, and utilization of cross-domain data sources. One of the significant outcomes of this effort is the development of a simple text and metadata representation for tabular data called GeoCSV, that allows straightforward interpretation of information from multiple domains by non-domain experts.
Multiple extrafoveal macular holes following internal limiting membrane peeling
Hussain, Nazimul; Mitra, Sandip
2018-01-01
Objective Internal limiting membrane (ILM) peeling has been the standard of treatment for macular holes. Besides, causing retinal nerve fiber layer surface abnormality, postoperative extrafoveal multiple retinal holes is a rare phenomenon following ILM peeling. We report an unusual complication of eight extrafoveal macular holes occurring following ILM peeling. Case presentation A 60-year-old male presented with complaints of decreased and distorted vision in the right eye. He was diagnosed as having epiretinal membrane with lamellar macular hole. He underwent 23G pars plana vitrectomy, brilliant blue assisted ILM peeling and fluid gas exchange. Intraoperatively, ILM was found to be adherent to the underlying neurosensory retina. One month after cataract surgery, he underwent YAG capsulotomy in the right eye. He complained of visual distortion. His fundus evaluation in the right eye showed multiple (eight) extrafoveal retinal holes temporal to the macula clustered together. Conclusion This case demonstrated that peeling of ILM, especially when it is adherent to the underlying neurosensory retina, may cause unwanted mechanical trauma to the inner retina. Glial apoptosis and neuronal degeneration may presumably play a role in delayed appearance of multiple (eight) extrafoveal macular holes, which has not been reported earlier. PMID:29760571
Multiple extrafoveal macular holes following internal limiting membrane peeling.
Hussain, Nazimul; Mitra, Sandip
2018-01-01
Internal limiting membrane (ILM) peeling has been the standard of treatment for macular holes. Besides, causing retinal nerve fiber layer surface abnormality, postoperative extrafoveal multiple retinal holes is a rare phenomenon following ILM peeling. We report an unusual complication of eight extrafoveal macular holes occurring following ILM peeling. A 60-year-old male presented with complaints of decreased and distorted vision in the right eye. He was diagnosed as having epiretinal membrane with lamellar macular hole. He underwent 23G pars plana vitrectomy, brilliant blue assisted ILM peeling and fluid gas exchange. Intraoperatively, ILM was found to be adherent to the underlying neurosensory retina. One month after cataract surgery, he underwent YAG capsulotomy in the right eye. He complained of visual distortion. His fundus evaluation in the right eye showed multiple (eight) extrafoveal retinal holes temporal to the macula clustered together. This case demonstrated that peeling of ILM, especially when it is adherent to the underlying neurosensory retina, may cause unwanted mechanical trauma to the inner retina. Glial apoptosis and neuronal degeneration may presumably play a role in delayed appearance of multiple (eight) extrafoveal macular holes, which has not been reported earlier.
Evaluation and Field Assessment of Bifacial Photovoltaic Module Power Rating Methodologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deline, Chris; MacAlpine, Sara; Marion, Bill
2016-11-21
1-sun power ratings for bifacial modules are currently undefined. This is partly because there is no standard definition of rear irradiance given 1000 Wm-2 on the front. Using field measurements and simulations, we evaluate multiple deployment scenarios for bifacial modules and provide details on the amount of irradiance that could be expected. A simplified case that represents a single module deployed under conditions consistent with existing 1-sun irradiance standards leads to a bifacial reference condition of 1000 Wm-2 Gfront and 130-140 Wm-2 Grear. For fielded systems of bifacial modules, Grear magnitude and spatial uniformity will be affected by self-shade frommore » adjacent modules, varied ground cover, and ground-clearance height. A standard measurement procedure for bifacial modules is also currently undefined. A proposed international standard is under development, which provides the motivation for this work. Here, we compare outdoor field measurements of bifacial modules with irradiance on both sides with proposed indoor test methods where irradiance is only applied to one side at a time. The indoor method has multiple advantages, including controlled and repeatable irradiance and thermal environment, along with allowing the use of conventional single-sided flash test equipment. The comparison results are promising, showing that the indoor and outdoor methods agree within 1%-2% for multiple rear-irradiance conditions and bifacial module types.« less
Evaluation and Field Assessment of Bifacial Photovoltaic Module Power Rating Methodologies: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deline, Chris; MacAlpine, Sara; Marion, Bill
2016-06-16
1-sun power ratings for bifacial modules are currently undefined. This is partly because there is no standard definition of rear irradiance given 1000 Wm-2 on the front. Using field measurements and simulations, we evaluate multiple deployment scenarios for bifacial modules and provide details on the amount of irradiance that could be expected. A simplified case that represents a single module deployed under conditions consistent with existing 1-sun irradiance standards leads to a bifacial reference condition of 1000 Wm-2 Gfront and 130-140 Wm-2 Grear. For fielded systems of bifacial modules, Grear magnitude and spatial uniformity will be affected by self-shade frommore » adjacent modules, varied ground cover, and ground-clearance height. A standard measurement procedure for bifacial modules is also currently undefined. A proposed international standard is under development, which provides the motivation for this work. Here, we compare outdoor field measurements of bifacial modules with irradiance on both sides with proposed indoor test methods where irradiance is only applied to one side at a time. The indoor method has multiple advantages, including controlled and repeatable irradiance and thermal environment, along with allowing the use of conventional single-sided flash test equipment. The comparison results are promising, showing that the indoor and outdoor methods agree within 1%-2% for multiple rear-irradiance conditions and bifacial module types.« less
Defining the clinical course of multiple sclerosis
Reingold, Stephen C.; Cohen, Jeffrey A.; Cutter, Gary R.; Sørensen, Per Soelberg; Thompson, Alan J.; Wolinsky, Jerry S.; Balcer, Laura J.; Banwell, Brenda; Barkhof, Frederik; Bebo, Bruce; Calabresi, Peter A.; Clanet, Michel; Comi, Giancarlo; Fox, Robert J.; Freedman, Mark S.; Goodman, Andrew D.; Inglese, Matilde; Kappos, Ludwig; Kieseier, Bernd C.; Lincoln, John A.; Lubetzki, Catherine; Miller, Aaron E.; Montalban, Xavier; O'Connor, Paul W.; Petkau, John; Pozzilli, Carlo; Rudick, Richard A.; Sormani, Maria Pia; Stüve, Olaf; Waubant, Emmanuelle; Polman, Chris H.
2014-01-01
Accurate clinical course descriptions (phenotypes) of multiple sclerosis (MS) are important for communication, prognostication, design and recruitment of clinical trials, and treatment decision-making. Standardized descriptions published in 1996 based on a survey of international MS experts provided purely clinical phenotypes based on data and consensus at that time, but imaging and biological correlates were lacking. Increased understanding of MS and its pathology, coupled with general concern that the original descriptors may not adequately reflect more recently identified clinical aspects of the disease, prompted a re-examination of MS disease phenotypes by the International Advisory Committee on Clinical Trials of MS. While imaging and biological markers that might provide objective criteria for separating clinical phenotypes are lacking, we propose refined descriptors that include consideration of disease activity (based on clinical relapse rate and imaging findings) and disease progression. Strategies for future research to better define phenotypes are also outlined. PMID:24871874
White, Helen E; Hedges, John; Bendit, Israel; Branford, Susan; Colomer, Dolors; Hochhaus, Andreas; Hughes, Timothy; Kamel-Reid, Suzanne; Kim, Dong-Wook; Modur, Vijay; Müller, Martin C; Pagnano, Katia B; Pane, Fabrizio; Radich, Jerry; Cross, Nicholas C P; Labourier, Emmanuel
2013-06-01
Current guidelines for managing Philadelphia-positive chronic myeloid leukemia include monitoring the expression of the BCR-ABL1 (breakpoint cluster region/c-abl oncogene 1, non-receptor tyrosine kinase) fusion gene by quantitative reverse-transcription PCR (RT-qPCR). Our goal was to establish and validate reference panels to mitigate the interlaboratory imprecision of quantitative BCR-ABL1 measurements and to facilitate global standardization on the international scale (IS). Four-level secondary reference panels were manufactured under controlled and validated processes with synthetic Armored RNA Quant molecules (Asuragen) calibrated to reference standards from the WHO and the NIST. Performance was evaluated in IS reference laboratories and with non-IS-standardized RT-qPCR methods. For most methods, percent ratios for BCR-ABL1 e13a2 and e14a2 relative to ABL1 or BCR were robust at 4 different levels and linear over 3 logarithms, from 10% to 0.01% on the IS. The intraassay and interassay imprecision was <2-fold overall. Performance was stable across 3 consecutive lots, in multiple laboratories, and over a period of 18 months to date. International field trials demonstrated the commutability of the reagents and their accurate alignment to the IS within the intra- and interlaboratory imprecision of IS-standardized methods. The synthetic calibrator panels are robust, reproducibly manufactured, analytically calibrated to the WHO primary standards, and compatible with most BCR-ABL1 RT-qPCR assay designs. The broad availability of secondary reference reagents will further facilitate interlaboratory comparative studies and independent quality assessment programs, which are of paramount importance for worldwide standardization of BCR-ABL1 monitoring results and the optimization of current and new therapeutic approaches for chronic myeloid leukemia. © 2013 American Association for Clinical Chemistry.
The effects of normal aging on multiple aspects of financial decision-making.
Bangma, Dorien F; Fuermaier, Anselm B M; Tucha, Lara; Tucha, Oliver; Koerts, Janneke
2017-01-01
Financial decision-making (FDM) is crucial for independent living. Due to cognitive decline that accompanies normal aging, older adults might have difficulties in some aspects of FDM. However, an improved knowledge, personal experience and affective decision-making, which are also related to normal aging, may lead to a stable or even improved age-related performance in some other aspects of FDM. Therefore, the present explorative study examines the effects of normal aging on multiple aspects of FDM. One-hundred and eighty participants (range 18-87 years) were assessed with eight FDM tests and several standard neuropsychological tests. Age effects were evaluated using hierarchical multiple regression analyses. The validity of the prediction models was examined by internal validation (i.e. bootstrap resampling procedure) as well as external validation on another, independent, sample of participants (n = 124). Multiple regression and correlation analyses were applied to investigate the mediation effect of standard measures of cognition on the observed effects of age on FDM. On a relatively basic level of FDM (e.g., paying bills or using FDM styles) no significant effects of aging were found. However more complex FDM, such as making decisions in accordance with specific rules, becomes more difficult with advancing age. Furthermore, an older age was found to be related to a decreased sensitivity for impulsive buying. These results were confirmed by the internal and external validation analyses. Mediation effects of numeracy and planning were found to explain parts of the association between one aspect of FDM (i.e. Competence in decision rules) and age; however, these cognitive domains were not able to completely explain the relation between age and FDM. Normal aging has a negative influence on a complex aspect of FDM, however, other aspects appear to be unaffected by normal aging or improve.
Medvedovici, Andrei; Albu, Florin; Sora, Iuliana Daniela; Udrescu, Stefan; Galaon, Toma; David, Victor
2009-10-01
A sensitive method for determination of free captopril as monobromobimane derivative in plasma samples is discussed. The internal standard (IS) was 5-methoxy-1H-benzimidazole-2-thiol. Derivatization with monobromobimane immediately after blood collection and plasma preparation prevents oxidation of captopril to the corresponding disulfide compound and enhances the ionization yield. Consequently, derivatization enhances sample stability and detection sensitivity. Addition of the internal standard was made immediately after plasma preparation. The internal standard was also derivatized by monobromobimane, as it contains a thiol functional group. Preparation of plasma samples containing captopril and IS derivatives was based upon protein precipitation through addition of acetonitrile, in a volumetric ratio 1:2. The reversed-phase liquid chromatographic separation was achieved on a rapid resolution cartridge Zorbax SB-C(18), monitored through positive electrospray ionization and tandem MS detection using the multiple-reaction monitoring mode. Transitions were 408-362 amu for the captopril derivative and 371-260 amu for the internal standard derivative. The kinetics of captopril oxidation to the corresponding disulfide compound in plasma matrix was also studied using the proposed method. A linear log-log calibration was obtained over the concentration interval 2.5-750 ng/mL. A low limit of quantitation in the 2.5 ng/mL range was obtained. The analytical method was fully validated and successfully applied in a three-way, three-period, single-dose (50 mg), block-randomized bioequivalence study for two pharmaceutical formulations (captopril LPH 25 and 50 mg) against the comparator Capoten 50 mg. Copyright (c) 2009 John Wiley & Sons, Ltd.
Zolg, Daniel Paul; Wilhelm, Mathias; Yu, Peng; Knaute, Tobias; Zerweck, Johannes; Wenschuh, Holger; Reimer, Ulf; Schnatbaum, Karsten; Kuster, Bernhard
2017-11-01
Beyond specific applications, such as the relative or absolute quantification of peptides in targeted proteomic experiments, synthetic spike-in peptides are not yet systematically used as internal standards in bottom-up proteomics. A number of retention time standards have been reported that enable chromatographic aligning of multiple LC-MS/MS experiments. However, only few peptides are typically included in such sets limiting the analytical parameters that can be monitored. Here, we describe PROCAL (ProteomeTools Calibration Standard), a set of 40 synthetic peptides that span the entire hydrophobicity range of tryptic digests, enabling not only accurate determination of retention time indices but also monitoring of chromatographic separation performance over time. The fragmentation characteristics of the peptides can also be used to calibrate and compare collision energies between mass spectrometers. The sequences of all selected peptides do not occur in any natural protein, thus eliminating the need for stable isotope labeling. We anticipate that this set of peptides will be useful for multiple purposes in individual laboratories but also aiding the transfer of data acquisition and analysis methods between laboratories, notably the use of spectral libraries. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
External Payload Interfaces on the International Space Station
NASA Astrophysics Data System (ADS)
Voels, S. A.; Eppler, D. B.; Park, B.
2000-12-01
The International Space Station (ISS) includes multiple payload locations that are external to the pressurized environment and that are suitable for astronomical and space science observations. These external or attached payload accommodation locations allow direct access to the space environment and fields of view that include the earth and/or space. NASA sponsored payloads will have access to several different types of standard external locations; the S3/P3 Truss Sites (with an EXPRESS Pallet interface), the Columbus Exposed Payload Facility (EPF), and the Japanese Experiment Module Exposed Facility (JEM-EF). Payload accommodations at each of the standard locations named above will be described, as well as transport to and retrieval from the site. The Office of Space Science's ISS Research Program Office has an allocation equivalent to 25% of the external space and opportunities for proposing to use this allocation will be as Missions of Opportunity through the normal Explorer (UNEX, SMEX, MIDEX) Announcements of Opportunity.
International Space Station (ISS)
2001-05-14
Astronaut James S. Voss, Expedition Two flight engineer, works with a series of cables on the EXPRESS Rack in the United State's Destiny laboratory on the International Space Station (ISS). The EXPRESS Rack is a standardized payload rack system that transports, stores, and supports experiments aboard the ISS. EXPRESS stands for EXpedite the PRocessing of Experiments to the Space Station, reflecting the fact that this system was developed specifically to maximize the Station's research capabilities. The EXPRESS Rack system supports science payloads in several disciplines, including biology, chemistry, physics, ecology, and medicine. With the EXPRESS Rack, getting experiments to space has never been easier or more affordable. With its standardized hardware interfaces and streamlined approach, the EXPRESS Rack enables quick, simple integration of multiple payloads aboard the ISS. The system is comprised of elements that remain on the ISS, as well as elements that travel back and forth between the ISS and Earth via the Space Shuttle.
Measuring health care process quality with software quality measures.
Yildiz, Ozkan; Demirörs, Onur
2012-01-01
Existing quality models focus on some specific diseases, clinics or clinical areas. Although they contain structure, process, or output type measures, there is no model which measures quality of health care processes comprehensively. In addition, due to the not measured overall process quality, hospitals cannot compare quality of processes internally and externally. To bring a solution to above problems, a new model is developed from software quality measures. We have adopted the ISO/IEC 9126 software quality standard for health care processes. Then, JCIAS (Joint Commission International Accreditation Standards for Hospitals) measurable elements were added to model scope for unifying functional requirements. Assessment (diagnosing) process measurement results are provided in this paper. After the application, it was concluded that the model determines weak and strong aspects of the processes, gives a more detailed picture for the process quality, and provides quantifiable information to hospitals to compare their processes with multiple organizations.
NASA Technical Reports Server (NTRS)
Kuch, T.; Sakamoto, R.
1981-01-01
An applications data service (ADS) was developed to meet the challenges in the data access and integration. The ADS provides a common service to locate and access applications data electronically and integrate the cross correlative data sets required by multiple users. Its catalog and network services increase data visibility as well as provide the data in a more rapid manner and a usable form.
Narayanaswamy, Rohini; Iyer, Vignesh; Khare, Prachi; Bodziak, Mary Lou; Badgett, Darlene; Zivadinov, Robert; Weinstock-Guttman, Bianca; Rideout, Todd C.; Ramanathan, Murali; Browne, Richard W.
2015-01-01
Background Oxysterols are promising biomarkers of neurodegenerative diseases that are linked with cholesterol and vitamin D metabolism. There is an unmet need for methods capable of sensitive, and simultaneous quantitation of multiple oxysterols, vitamin D and cholesterol pathway biomarkers. Methods A method for simultaneous determination of 5 major oxysterols, 25-hydroxy vitamin D3 and cholesterol in human plasma was developed. Total oxysterols were prepared by room temperature saponification followed by solid phase extraction from plasma spiked with deuterated internal standards. Oxysterols were resolved by reverse phase HPLC using a methanol/water/0.1% formic acid gradient. Oxysterols and 25-hydroxy vitamin D3 were detected with atmospheric pressure chemical ionization mass spectrometry in positive ion mode; in-series photodiode array detection at 204nm was used for cholesterol. Method validation studies were performed. Oxysterol levels in 220 plasma samples from healthy control subjects, multiple sclerosis and other neurological disorders patients were quantitated. Results Our method quantitated 5 oxysterols, cholesterol and 25-hydroxy vitamin D3 from 200 μL plasma in 35 minutes. Recoveries were >85% for all analytes and internal standards. The limits of detection were 3-10 ng/mL for oxysterols and 25-hydroxy vitamin D3 and 1 μg/mL for simultaneous detection of cholesterol. Analytical imprecision was <10 %CV for 24(S)-, 25-, 27-, 7α-hydroxycholesterol (HC) and cholesterol and ≤15 % for 7-keto-cholesterol. Multiple Sclerosis and other neurological disorder patients had lower 27-hydroxycholesterol levels compared to controls whereas 7α-hydroxycholesterol was lower specifically in Multiple Sclerosis. Conclusion The method is suitable for measuring plasma oxysterols levels in human health and disease. Analysis of human plasma indicates that the oxysterol, bile acid precursors 7α-hydroxycholesterol and 27-hydroxycholesterol are lower in Multiple Sclerosis and may serve as potential biomarkers of disease. PMID:25875771
Developing product quality standards for wheelchairs used in less-resourced environments
McCambridge, Matt; Reese, Norman; Schoendorfer, Don; Wunderlich, Eric; Rushman, Chris; Mahilo, Dave
2017-01-01
Background Premature failures of wheelchairs in less-resourced environments (LREs) may be because of shortcomings in product regulation and quality standards. The standards published by the International Organization for Standardization (ISO) specify wheelchair tests for durability, safety and performance, but their applicability to products used in the rugged conditions of LREs is unclear. Because of this, wheelchair-related guidelines published by the World Health Organization recommended developing more rigorous durability tests for wheelchairs. Objectives This study was performed to identify the additional tests needed for LREs. Methods First, a literature review of the development of ISO test standards, wheelchair standards testing studies and wheelchair evaluations in LREs was performed. Second, expert advice from members of the Standards Working Group of the International Society of Wheelchair Professionals (ISWP) was compiled and reviewed. Results A total of 35 articles were included in the literature review. Participation from LREs was not observed in the ISO standards development. As per wheelchair testing study evidence, wheelchair models delivered in LREs did not meet the minimum standards requirement. Multiple part failures and repairs were observed with reviewed field evaluation studies. ISWP experts noted that several testing factors responsible for premature failures with wheelchair parts are not included in the standards and accordingly provided advice for additional test development. Conclusion The study findings indicate the need to develop a wide range of tests, with specific tests for measuring corrosion resistance of the entire wheelchair, rolling resistance of castors and rear wheels, and durability of whole wheelchair and castor assemblies. PMID:28936410
Determination of tiropramide in human plasma by liquid chromatography-tandem mass spectrometry.
Lee, Hye Won; Ji, Hye Young; Kim, Hee Hyun; Cho, Hea-Young; Lee, Yong-Bok; Lee, Hye Suk
2003-11-05
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of tiropramide in human plasma was developed. Tiropramide and internal standard, cisapride were extracted from human plasma by liquid-liquid extraction and analyzed on a Luna C8 column with the mobile phase of acetonitrile-ammonium formate (10mM, pH 4.5) (50:50, v/v). The analytes was detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.998) over the concentration range of 2.0-200 ng/ml. The intra- and inter-assay coefficients of variation ranged from 2.8 to 7.8 and 6.7 to 8.9%, respectively. The recoveries of tiropramide ranged from 50.2 to 53.1%, with that of cisapride (internal standard) being 60.9+/-5.3%. The lower limit of quantification for tiropramide was 2.0 ng/ml using 100 microl plasma sample. This method was applied to the pharmacokinetic study of tiropramide in human.
NASA Technical Reports Server (NTRS)
Gary, G. Allen; Moore, R. L.
2003-01-01
We present observations and an interpretation of a unique multiple-turn spiral flux tube eruption from AR10030 on 2002 July 15. The TRACE CIV observations clearly show a flux tube that is helical and that is erupting from within a sheared magnetic field. These observations are interpreted in the context of the breakout model for magnetic field explosions. The initiation of the helix eruption starts 25 seconds after the peak of the flare s strongest impulsive spike of microwave gryosynchrotron radiation early in the flare s explosive phase, implying that the sheared core field is not the site of the initial reconnection. Within the quadrupolar configuration of the active region, the external and internal reconnection sites are identified in each of two consecutive eruptive flares that produce a double CME. The first external breakout reconnection apparently releases an underlying sheared core field and allows it to erupt, leading to internal reconnection in the wake of the erupting helix. This internal reconnection heats the two-ribbon flare and might or might not produce the helix. These events lead to the first CME and are followed by a second breakout that initiates a second and larger halo CME. The strong magnetic shear in the region is associated with rapid proper motion and evolution of the active region. The multiple-turn helix originates from above a sheared-field magnetic inversion line within a filament channel, and starts to erupt only after fast breakout reconnection has started. These observations are counter to the standard flare model and support the breakout model for eruptive flare initiation. However, the observations are compatible with internal reconnection in a sheared magnetic arcade in the formation and eruption of the helix.
Bisgaard, N
2001-06-01
This article presents an overview of past and current experiences with time division multiple assess-based (Global System for Mobil Communication) mobile telephones in Europe as seen by the European Hearing Instrument Manufacturers Association. Initial fear of widespread interference problems for hearing aid users in general owing to use of a new generation of mobile telephones seems unjustified. The background for the International Electrotechnical Commission 118-13 standard for measuring interference is described. No solution to complete elimination of interference problems resulting from direct contact between hearing aids and mobile telephones has yet been found. Several reports on the subjects are cited, and new work on measurement standards for near-field situations is mentioned.
Standard payload computer for the international space station
NASA Astrophysics Data System (ADS)
Knott, Karl; Taylor, Chris; Koenig, Horst; Schlosstein, Uwe
1999-01-01
This paper describes the development and application of a Standard PayLoad Computer (SPLC) which is being applied by the majority of ESA payloads accommodated on the International Space Station (ISS). The strategy of adopting of a standard computer leads to a radical rethink in the payload data handling procurement process. Traditionally, this has been based on a proprietary development with repeating costs for qualification, spares, expertise and maintenance for each new payload. Implementations have also tended to be unique with very little opportunity for reuse or utilisation of previous developments. While this may to some extent have been justified for short duration one-off missions, the availability of a standard, long term space infrastructure calls for a quite different approach. To support a large number of concurrent payloads, the ISS implementation relies heavily on standardisation, and this is particularly true in the area of payloads. Physical accommodation, data interfaces, protocols, component quality, operational requirements and maintenance including spares provisioning must all conform to a common set of standards. The data handling system and associated computer used by each payload must also comply with these common requirements, and thus it makes little sense to instigate multiple developments for the same task. The opportunity exists to provide a single computer suitable for all payloads, but with only a one-off development and qualification cost. If this is combined with the benefits of multiple procurement, centralised spares and maintenance, there is potential for great savings to be made by all those concerned in the payload development process. In response to the above drivers, the SPLC is based on the following concepts: • A one-off development and qualification process • A modular computer, configurable according to the payload developer's needs from a list of space-qualified items • An `open system' which may be added to by payload developers • Core software providing a suite of common communications services including a verified protocol implementation required to communicate with the ISS • A standardized ground support equipment and accompanying software development environment • The use of commercial hardware and software standards and products.
Recent advances in standards for collaborative Digital Anatomic Pathology
2011-01-01
Context Collaborative Digital Anatomic Pathology refers to the use of information technology that supports the creation and sharing or exchange of information, including data and images, during the complex workflow performed in an Anatomic Pathology department from specimen reception to report transmission and exploitation. Collaborative Digital Anatomic Pathology can only be fully achieved using medical informatics standards. The goal of the international integrating the Healthcare Enterprise (IHE) initiative is precisely specifying how medical informatics standards should be implemented to meet specific health care needs and making systems integration more efficient and less expensive. Objective To define the best use of medical informatics standards in order to share and exchange machine-readable structured reports and their evidences (including whole slide images) within hospitals and across healthcare facilities. Methods Specific working groups dedicated to Anatomy Pathology within multiple standards organizations defined standard-based data structures for Anatomic Pathology reports and images as well as informatic transactions in order to integrate Anatomic Pathology information into the electronic healthcare enterprise. Results The DICOM supplements 122 and 145 provide flexible object information definitions dedicated respectively to specimen description and Whole Slide Image acquisition, storage and display. The content profile “Anatomic Pathology Structured Report” (APSR) provides standard templates for structured reports in which textual observations may be bound to digital images or regions of interest. Anatomic Pathology observations are encoded using an international controlled vocabulary defined by the IHE Anatomic Pathology domain that is currently being mapped to SNOMED CT concepts. Conclusion Recent advances in standards for Collaborative Digital Anatomic Pathology are a unique opportunity to share or exchange Anatomic Pathology structured reports that are interoperable at an international level. The use of machine-readable format of APSR supports the development of decision support as well as secondary use of Anatomic Pathology information for epidemiology or clinical research. PMID:21489187
[International collaboration to develop a nurse practitioner master's program].
Tang, Woung-Ru
2007-12-01
Because of the shortage of resident doctors and in order to raise standards, hospitals and medical centers have trained their own nurse practitioners (NPs). Given the absence of standard training criteria and an unevenness of faculty quality, however, many NPs play the role of medical substitute, which is far from the independent role performed by NPs in foreign countries. It is therefore necessary to include NP training within higher education. The Graduate Institute of Nursing at Chang Gung University established the first NP in-service training program in 2003 through international collaboration, with the purpose of cultivating advanced clinical nursing talents. The program emphasizes the importance of clinical reasoning and practical training, in order to enable students to perform the multiple roles of treatment and caring undertaken by NPs. Experts in advanced nursing and clinical medicine from Taiwan and abroad were invited to serve as lecturers. The students also had the opportunity to take NP courses at Oregon Health and Science University (USA) and participate in clinical visits. The results have been widely praised. International collaboration is built upon the mutual trust of the parties, and its success is determined by the measures that it involves, as well as by the global vision and competence of participants. This paper shares the advantages and disadvantages of the NP master's program through international collaboration.
Mortality in a Combined Cohort of Uranium Enrichment Workers
Yiin, James H.; Anderson, Jeri L.; Daniels, Robert D.; Bertke, Stephen J.; Fleming, Donald A.; Tollerud, David J.; Tseng, Chih-Yu; Chen, Pi-Hsueh; Waters, Kathleen M.
2017-01-01
Objective To examine the patterns of cause-specific mortality and relationship between internal exposure to uranium and specific causes in a pooled cohort of 29,303 workers employed at three former uranium enrichment facilities in the United States with follow-up through 2011. Methods Cause-specific standardized mortality ratios (SMRs) for the full cohort were calculated with the U.S. population as referent. Internal comparison of the dose-response relation between selected outcomes and estimated organ doses was evaluated using regression models. Results External comparison with the U.S. population showed significantly lower SMRs in most diseases in the pooled cohort. Internal comparison showed positive associations of absorbed organ doses with multiple myeloma, and to a lesser degree with kidney cancer. Conclusion In general, these gaseous diffusion plant workers had significantly lower SMRs than the U.S. population. The internal comparison however, showed associations between internal organ doses and diseases associated with uranium exposure in previous studies. PMID:27753121
Mtove, George; Kimani, Joshua; Kisinza, William; Makenga, Geofrey; Mangesho, Peter; Duparc, Stephan; Nakalembe, Miriam; Phiri, Kamija S; Orrico, Russell; Rojo, Ricardo; Vandenbroucke, Pol
2018-03-22
Multinational clinical trials are logistically complex and require close coordination between various stakeholders. They must comply with global clinical standards and are accountable to multiple regulatory and ethical bodies. In resource-limited settings, it is challenging to understand how to apply global clinical standards to international, national, and local factors in clinical trials, making multiple-level stakeholder engagement an important element in the successful conduct of these clinical trials. During the planning and implementation of a large multinational clinical trial for intermittent preventive treatment of malaria in pregnancy in resource-limited areas of sub-Saharan Africa, we encountered numerous challenges, which required implementation of a range of engagement measures to ensure compliance with global clinical and regulatory standards. These challenges included coordination with ongoing global malaria efforts, heterogeneity in national regulatory structures, sub-optimal healthcare infrastructure, local practices and beliefs, and perspectives that view healthcare providers with undue trust or suspicion. In addition to engagement with international bodies, such as the World Health Organization, the Malaria in Pregnancy Consortium, the Steve Biko Centre for Bioethics, and the London School of Hygiene and Tropical Medicine, in order to address the challenges just described, Pfizer Inc. and Medicines for Malaria Venture (the "Sponsoring Entities" for these studies) and investigators liaised with national- and district-level stakeholders such as health ministers and regional/local community health workers. Community engagement measures undertaken by investigators included local meetings with community leaders to explain the research aims and answer questions and concerns voiced by the community. The investigators also engaged with family members of prospective trial participants in order to be sensitive to local practices and beliefs. Engagement with key stakeholders at international and national levels enabled the Sponsoring Entities to address challenges by aligning the study design with the requirements of health and regulatory agencies and to understand and address healthcare infrastructure needs prior to trial initiation. Local stakeholder engagement, including community members, study participants, and family enabled the investigators to address challenges by ensuring that study design and conduct were adapted to local considerations and ensuring accurate information about the study aims was shared with the public. ClinicalTrials.gov, ID: NCT01103063 . Registered on 7 April 2010.
Ausserhofer, Dietmar; Rakic, Severin; Novo, Ahmed; Dropic, Emira; Fisekovic, Eldin; Sredic, Ana; Van Malderen, Greet
2016-06-01
We explored how selected 'positive deviant' healthcare facilities in Bosnia and Herzegovina approach the continuous development, adaptation, implementation, monitoring and evaluation of nursing-related standard operating procedures. Standardized nursing care is internationally recognized as a critical element of safe, high-quality health care; yet very little research has examined one of its key instruments: nursing-related standard operating procedures. Despite variability in Bosnia and Herzegovina's healthcare and nursing care quality, we assumed that some healthcare facilities would have developed effective strategies to elevate nursing quality and safety through the use of standard operating procedures. Guided by the 'positive deviance' approach, we used a multiple-case study design to examine a criterion sample of four facilities (two primary healthcare centres and two hospitals), collecting data via focus groups and individual interviews. In each studied facility, certification/accreditation processes were crucial to the initiation of continuous development, adaptation, implementation, monitoring and evaluation of nursing-related SOPs. In one hospital and one primary healthcare centre, nurses working in advanced roles (i.e. quality coordinators) were responsible for developing and implementing nursing-related standard operating procedures. Across the four studied institutions, we identified a consistent approach to standard operating procedures-related processes. The certification/accreditation process is enabling necessary changes in institutions' organizational cultures, empowering nurses to take on advanced roles in improving the safety and quality of nursing care. Standardizing nursing procedures is key to improve the safety and quality of nursing care. Nursing and Health Policy are needed in Bosnia and Herzegovina to establish a functioning institutional framework, including regulatory bodies, educational systems for developing nurses' capacities or the inclusion of nursing-related standard operating procedures in certification/accreditation standards. © 2016 International Council of Nurses.
Valkenborg, Dirk; Baggerman, Geert; Vanaerschot, Manu; Witters, Erwin; Dujardin, Jean-Claude; Burzykowski, Tomasz; Berg, Maya
2013-01-01
Abstract Combining liquid chromatography-mass spectrometry (LC-MS)-based metabolomics experiments that were collected over a long period of time remains problematic due to systematic variability between LC-MS measurements. Until now, most normalization methods for LC-MS data are model-driven, based on internal standards or intermediate quality control runs, where an external model is extrapolated to the dataset of interest. In the first part of this article, we evaluate several existing data-driven normalization approaches on LC-MS metabolomics experiments, which do not require the use of internal standards. According to variability measures, each normalization method performs relatively well, showing that the use of any normalization method will greatly improve data-analysis originating from multiple experimental runs. In the second part, we apply cyclic-Loess normalization to a Leishmania sample. This normalization method allows the removal of systematic variability between two measurement blocks over time and maintains the differential metabolites. In conclusion, normalization allows for pooling datasets from different measurement blocks over time and increases the statistical power of the analysis, hence paving the way to increase the scale of LC-MS metabolomics experiments. From our investigation, we recommend data-driven normalization methods over model-driven normalization methods, if only a few internal standards were used. Moreover, data-driven normalization methods are the best option to normalize datasets from untargeted LC-MS experiments. PMID:23808607
Pathology Imagebase-a reference image database for standardization of pathology.
Egevad, Lars; Cheville, John; Evans, Andrew J; Hörnblad, Jonas; Kench, James G; Kristiansen, Glen; Leite, Katia R M; Magi-Galluzzi, Cristina; Pan, Chin-Chen; Samaratunga, Hemamali; Srigley, John R; True, Lawrence; Zhou, Ming; Clements, Mark; Delahunt, Brett
2017-11-01
Despite efforts to standardize histopathology practice through the development of guidelines, the interpretation of morphology is still hampered by subjectivity. We here describe Pathology Imagebase, a novel mechanism for establishing an international standard for the interpretation of pathology specimens. The International Society of Urological Pathology (ISUP) established a reference image database through the input of experts in the field. Three panels were formed, one each for prostate, urinary bladder and renal pathology, consisting of 24 international experts. Each of the panel members uploaded microphotographs of cases into a non-public database. The remaining 23 experts were asked to vote from a multiple-choice menu. Prior to and while voting, panel members were unable to access the results of voting by the other experts. When a consensus level of at least two-thirds or 16 votes was reached, cases were automatically transferred to the main database. Consensus was reached in a total of 287 cases across five projects on the grading of prostate, bladder and renal cancer and the classification of renal tumours and flat lesions of the bladder. The full database is available to all ISUP members at www.isupweb.org. Non-members may access a selected number of cases. It is anticipated that the database will assist pathologists in calibrating their grading, and will also promote consistency in the diagnosis of difficult cases. © 2017 John Wiley & Sons Ltd.
Use of Electronic Health Record Simulation to Understand the Accuracy of Intern Progress Notes
March, Christopher A.; Scholl, Gretchen; Dversdal, Renee K.; Richards, Matthew; Wilson, Leah M.; Mohan, Vishnu; Gold, Jeffrey A.
2016-01-01
Background With the widespread adoption of electronic health records (EHRs), there is a growing awareness of problems in EHR training for new users and subsequent problems with the quality of information present in EHR-generated progress notes. By standardizing the case, simulation allows for the discovery of EHR patterns of use as well as a modality to aid in EHR training. Objective To develop a high-fidelity EHR training exercise for internal medicine interns to understand patterns of EHR utilization in the generation of daily progress notes. Methods Three months after beginning their internship, 32 interns participated in an EHR simulation designed to assess patterns in note writing and generation. Each intern was given a simulated chart and instructed to create a daily progress note. Notes were graded for use of copy-paste, macros, and accuracy of presented data. Results A total of 31 out of 32 interns (97%) completed the exercise. There was wide variance in use of macros to populate data, with multiple macro types used for the same data category. Three-quarters of notes contained either copy-paste elements or the elimination of active medical problems from the prior days' notes. This was associated with a significant number of quality issues, including failure to recognize a lack of deep vein thrombosis prophylaxis, medications stopped on admission, and issues in prior discharge summary. Conclusions Interns displayed wide variation in the process of creating progress notes. Additional studies are being conducted to determine the impact EHR-based simulation has on standardization of note content. PMID:27168894
Use of Electronic Health Record Simulation to Understand the Accuracy of Intern Progress Notes.
March, Christopher A; Scholl, Gretchen; Dversdal, Renee K; Richards, Matthew; Wilson, Leah M; Mohan, Vishnu; Gold, Jeffrey A
2016-05-01
Background With the widespread adoption of electronic health records (EHRs), there is a growing awareness of problems in EHR training for new users and subsequent problems with the quality of information present in EHR-generated progress notes. By standardizing the case, simulation allows for the discovery of EHR patterns of use as well as a modality to aid in EHR training. Objective To develop a high-fidelity EHR training exercise for internal medicine interns to understand patterns of EHR utilization in the generation of daily progress notes. Methods Three months after beginning their internship, 32 interns participated in an EHR simulation designed to assess patterns in note writing and generation. Each intern was given a simulated chart and instructed to create a daily progress note. Notes were graded for use of copy-paste, macros, and accuracy of presented data. Results A total of 31 out of 32 interns (97%) completed the exercise. There was wide variance in use of macros to populate data, with multiple macro types used for the same data category. Three-quarters of notes contained either copy-paste elements or the elimination of active medical problems from the prior days' notes. This was associated with a significant number of quality issues, including failure to recognize a lack of deep vein thrombosis prophylaxis, medications stopped on admission, and issues in prior discharge summary. Conclusions Interns displayed wide variation in the process of creating progress notes. Additional studies are being conducted to determine the impact EHR-based simulation has on standardization of note content.
Achieving interoperability for metadata registries using comparative object modeling.
Park, Yu Rang; Kim, Ju Han
2010-01-01
Achieving data interoperability between organizations relies upon agreed meaning and representation (metadata) of data. For managing and registering metadata, many organizations have built metadata registries (MDRs) in various domains based on international standard for MDR framework, ISO/IEC 11179. Following this trend, two pubic MDRs in biomedical domain have been created, United States Health Information Knowledgebase (USHIK) and cancer Data Standards Registry and Repository (caDSR), from U.S. Department of Health & Human Services and National Cancer Institute (NCI), respectively. Most MDRs are implemented with indiscriminate extending for satisfying organization-specific needs and solving semantic and structural limitation of ISO/IEC 11179. As a result it is difficult to address interoperability among multiple MDRs. In this paper, we propose an integrated metadata object model for achieving interoperability among multiple MDRs. To evaluate this model, we developed an XML Schema Definition (XSD)-based metadata exchange format. We created an XSD-based metadata exporter, supporting both the integrated metadata object model and organization-specific MDR formats.
Assessment of bifacial photovoltaic module power rating methodologies–inside and out
Deline, Chris; MacAlpine, Sara; Marion, Bill; ...
2017-01-26
One-sun power ratings for bifacial modules are currently undefined. This is partly because there is no standard definition of rear irradiance given 1000 W·m -2 on the front. Using field measurements and simulations, we evaluate multiple deployment scenarios for bifacial modules and provide details on the amount of irradiance that could be expected. A simplified case that represents a single module deployed under conditions consistent with existing one-sun irradiance standards lead to a bifacial reference condition of 1000 W·m -2 G front and 130-140 W·m -2 G rear. For fielded systems of bifacial modules, Grear magnitude and spatial uniformity willmore » be affected by self-shade from adjacent modules, varied ground cover, and ground-clearance height. A standard measurement procedure for bifacial modules is also currently undefined. A proposed international standard is under development, which provides the motivation for this paper. Here, we compare field measurements of bifacial modules under natural illumination with proposed indoor test methods, where irradiance is only applied to one side at a time. The indoor method has multiple advantages, including controlled and repeatable irradiance and thermal environment, along with allowing the use of conventional single-sided flash test equipment. The comparison results are promising, showing that indoor and outdoor methods agree within 1%-2% for multiple rear-irradiance conditions and bifacial module construction. Furthermore, a comparison with single-diode theory also shows good agreement to indoor measurements, within 1%-2% for power and other current-voltage curve parameters.« less
Hybrid Multiagent System for Automatic Object Learning Classification
NASA Astrophysics Data System (ADS)
Gil, Ana; de La Prieta, Fernando; López, Vivian F.
The rapid evolution within the context of e-learning is closely linked to international efforts on the standardization of learning object metadata, which provides learners in a web-based educational system with ubiquitous access to multiple distributed repositories. This article presents a hybrid agent-based architecture that enables the recovery of learning objects tagged in Learning Object Metadata (LOM) and provides individualized help with selecting learning materials to make the most suitable choice among many alternatives.
Laser-ablation ICP-MS as a tool for whole rock trace element analyses on fused powders
NASA Astrophysics Data System (ADS)
Girard, G.; Rooney, T. O.
2013-12-01
Here we present an accurate and precise technique for routine trace element analysis of geologic materials by laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). We focus on rock powders previously prepared for X-ray fluorescence by fusion in a Li2B4O7 flux, and subsequently quenched in a Pt mold to form a glass disk. Our method allows for the analysis up to 30 trace elements by LA-ICP-MS using a Photon-Machines Analyte G2 193 nm excimer laser coupled to a Thermo-Fisher Scientific ICAP Q quadrupole ICP-MS. Analyses are run as scans on the surface of the disks. Laser ablation conditions for which trace element fractionation effects are minimal have been empirically determined to be ~ 4 J m-2 fluence, at 10 Hz , and 10 μm s-1 scan speed, using a 110 μm laser beam size. Ablated material is carried into the ICP-MS by a He carrier at a rate of 0.75 L min-1. Following pre-ablation to remove surface particles, samples are ablated for 200 s, of which 140 s are used for data acquisition. At the end of each scan, a gas blank is collected for 30 s. Dwell times for each element vary between 15 and 60 μs, depending on abundance and instrument sensitivity, allowing 120 readings of each element during the data acquisition time window. To correct for variations in the total volume of material extracted by the laser, three internal standards are used, Ca, Fe and Zr. These elements are routinely analyzed by X-ray fluorescence by the Geoanalytical laboratory at Michigan State University with precision and accuracy of <5%. The availability of several internal standards allows for better correction of possible persisting laser ablation fractionation effects; for a particular trace element, we correct using the internal standard that best reproduces its ablation behavior. Our calibration is based on a combination of fused powders of US Geological Survey and Geological Survey of Japan rock standards, NIST SRM 612 glass, and US Geological Survey natural and synthetic basalt glasses. Instrumental drift is monitored during each run using two fused standards analyzed multiple times as unknowns. We routinely achieve an external precision of <5% on multiple replicates of standards run as unknowns, which are also within <5% of certified values. Elements analyzed include most first row transition metals, large ion lithophile elements, high field strength elements, lanthanide and actinide rare earth elements.
Na Kim, Ha; Yeol Kim, Dong; Hee Oh, Se; Sook Kim, Hyung; Suk Kim, Kyung
2017-01-01
Abstract Multiple system atrophy (MSA) is a sporadic neurodegenerative disease of the central and autonomic nervous system. Because no drug treatment consistently benefits MSA patients, neuroprotective strategy using mesenchymal stem cells (MSCs) has a lot of concern for the management of MSA. In this study, we investigated the safety and efficacy of intra‐arterial administration of MSCs via internal carotid artery (ICA) in an animal model of MSA. The study was composed of feasibility test using a ×10 and ×50 of a standard dose of MSCs (4 × 107 MSCs) and efficacy test using a ×0.2, ×2, and ×20 of the standard dose. An ultrasonic flow meter and magnetic resonance imaging (MRI) showed that no cerebral ischemic lesions with patent ICA blood flow was were observed in animals receiving a ×10 of the standard dose of MSCs. However, no MSA animals receiving a ×50 of the standard dose survived. In efficacy test, animals injected with a ×2 of the standard dose increased nigrostriatal neuronal survival relative to a ×0.2 or ×20 of the standard dose. MSA animals receiving MSCs at ×0.2 and ×2 concentrations of the standard dose exhibited a significant reduction in rotation behavior relative to ×20 of the standard dose of MSCs. Cerebral ischemic lesions on MRI were only observed in MSA animals receiving a ×20 of the standard dose. The present study revealed that if their concentration is appropriate, intra‐arterial injection of MSCs is safe and exerts a neuroprotective effect on striatal and nigral neurons with a coincidental improvement in motor behavior. Stem Cells Translational Medicine 2017;6:1424–1433 PMID:28296268
Palumbo, Antonio; Rajkumar, S. Vincent; San Miguel, Jesus F.; Larocca, Alessandra; Niesvizky, Ruben; Morgan, Gareth; Landgren, Ola; Hajek, Roman; Einsele, Hermann; Anderson, Kenneth C.; Dimopoulos, Meletios A.; Richardson, Paul G.; Cavo, Michele; Spencer, Andrew; Stewart, A. Keith; Shimizu, Kazuyuki; Lonial, Sagar; Sonneveld, Pieter; Durie, Brian G.M.; Moreau, Philippe; Orlowski, Robert Z.
2014-01-01
Purpose To provide an update on recent advances in the management of patients with multiple myeloma who are not eligible for autologous stem-cell transplantation. Methods A comprehensive review of the literature on diagnostic criteria is provided, and treatment options and management of adverse events are summarized. Results Patients with symptomatic disease and organ damage (ie, hypercalcemia, renal failure, anemia, or bone lesions) require immediate treatment. The International Staging System and chromosomal abnormalities identify high- and standard-risk patients. Proteasome inhibitors, immunomodulatory drugs, corticosteroids, and alkylating agents are the most active agents. The presence of concomitant diseases, frailty, or disability should be assessed and, if present, treated with reduced-dose approaches. Bone disease, renal damage, hematologic toxicities, infections, thromboembolism, and peripheral neuropathy are the most frequent disabling events requiring prompt and active supportive care. Conclusion These recommendations will help clinicians ensure the most appropriate care for patients with myeloma in everyday clinical practice. PMID:24419113
Crew factors in flight operations. Part 4: Sleep and wakefulness in international aircrews
NASA Technical Reports Server (NTRS)
Graeber, R. C.
1986-01-01
Physiological recordings of sleep and wakefulness in operating international (B-747) flight crews were obtained. Crews spent their first layover (48 h) of a trip in a sleep laboratory where standardized EEG, electro-oculograph (EOC), and electromyograph (EMG) sleep recordings were carried out whenever volunteers chose to sleep. During periods of wakefulness they underwent multiple sleep latency tests every 2 h in order to assess daytime drowsiness. The same standardized recordings were carried out at a home-based laboratory before departure. Approximately four crews each participated in flights over 7 to 9 time zones on five routes. All participants were encouraged to use whatever sleep-wake strategies they thought would provide them with the most satisfactory crew rest. Overall, layover sleep quality was not seriously disturbed, but eastward flights produced greater sleep disruption. The contributors of individual factors and the usefulness of various sleep strategies are discussed in the individual laboratory reports and in an operational summary.
Wang, Chunyan; Zhang, Wenyan; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying
2012-05-01
The analysis by electrospray-ionization tandem mass spectrometry of amino acids with butyl esterification and isotopically labeled internal standard is routine in newborn screening laboratories worldwide. In the present study, we established a direct analysis method of higher accuracy that uses a non-deuterated internal standard. The automatic sampler and the pump of an LC apparatus were used to inject sample and mobile phase to MS, but no LC column was needed. The dry blood spot (DBS) material was prepared at levels of low, medium and high concentration; the running time was 1 min. In parallel to the new procedure, we applied the established method to analyze nine amino acids on DBS of healthy newborns and phenylketonuria newborns. The newly proposed method of product ion confirmation scan along with multiple reaction monitoring resulted in a very accurate identification of each amino acid. Our innovative protocol had high sensitivity and specificity in the analysis of cases of suspected metabolic diseases.
Viidanoja, Jyrki
2015-09-15
A new, sensitive and selective liquid chromatography-electrospray ionization-tandem mass spectrometric (LC-ESI-MS/MS) method was developed for the analysis of Phospholipids (PLs) in bio-oils and fats. This analysis employs hydrophilic interaction liquid chromatography-scheduled multiple reaction monitoring (HILIC-sMRM) with a ZIC-cHILIC column. Eight PL class selective internal standards (homologs) were used for the semi-quantification of 14 PL classes for the first time. More than 400 scheduled MRMs were used for the measurement of PLs with a run time of 34min. The method's performance was evaluated for vegetable oil, animal fat and algae oil. The averaged within-run precision and between-run precision were ≤10% for all of the PL classes that had a direct homologue as an internal standard. The method accuracy was generally within 80-120% for the tested PL analytes in all three sample matrices. Copyright © 2015 Elsevier B.V. All rights reserved.
The effects of normal aging on multiple aspects of financial decision-making
Bangma, Dorien F.; Fuermaier, Anselm B. M.; Tucha, Lara; Tucha, Oliver; Koerts, Janneke
2017-01-01
Objectives Financial decision-making (FDM) is crucial for independent living. Due to cognitive decline that accompanies normal aging, older adults might have difficulties in some aspects of FDM. However, an improved knowledge, personal experience and affective decision-making, which are also related to normal aging, may lead to a stable or even improved age-related performance in some other aspects of FDM. Therefore, the present explorative study examines the effects of normal aging on multiple aspects of FDM. Methods One-hundred and eighty participants (range 18–87 years) were assessed with eight FDM tests and several standard neuropsychological tests. Age effects were evaluated using hierarchical multiple regression analyses. The validity of the prediction models was examined by internal validation (i.e. bootstrap resampling procedure) as well as external validation on another, independent, sample of participants (n = 124). Multiple regression and correlation analyses were applied to investigate the mediation effect of standard measures of cognition on the observed effects of age on FDM. Results On a relatively basic level of FDM (e.g., paying bills or using FDM styles) no significant effects of aging were found. However more complex FDM, such as making decisions in accordance with specific rules, becomes more difficult with advancing age. Furthermore, an older age was found to be related to a decreased sensitivity for impulsive buying. These results were confirmed by the internal and external validation analyses. Mediation effects of numeracy and planning were found to explain parts of the association between one aspect of FDM (i.e. Competence in decision rules) and age; however, these cognitive domains were not able to completely explain the relation between age and FDM. Conclusion Normal aging has a negative influence on a complex aspect of FDM, however, other aspects appear to be unaffected by normal aging or improve. PMID:28792973
NASA Astrophysics Data System (ADS)
Evans, Ben; Wyborn, Lesley; Druken, Kelsey; Richards, Clare; Trenham, Claire; Wang, Jingbo; Rozas Larraondo, Pablo; Steer, Adam; Smillie, Jon
2017-04-01
The National Computational Infrastructure (NCI) facility hosts one of Australia's largest repositories (10+ PBytes) of research data collections spanning datasets from climate, coasts, oceans, and geophysics through to astronomy, bioinformatics, and the social sciences domains. The data are obtained from national and international sources, spanning a wide range of gridded and ungridded (i.e., line surveys, point clouds) data, and raster imagery, as well as diverse coordinate reference projections and resolutions. Rather than managing these data assets as a digital library, whereby users can discover and download files to personal servers (similar to borrowing 'books' from a 'library'), NCI has built an extensive and well-integrated research data platform, the National Environmental Research Data Interoperability Platform (NERDIP, http://nci.org.au/data-collections/nerdip/). The NERDIP architecture enables programmatic access to data via standards-compliant services for high performance data analysis, and provides a flexible cloud-based environment to facilitate the next generation of transdisciplinary scientific research across all data domains. To improve use of modern scalable data infrastructures that are focused on efficient data analysis, the data organisation needs to be carefully managed including performance evaluations of projections and coordinate systems, data encoding standards and formats. A complication is that we have often found multiple domain vocabularies and ontologies are associated with equivalent datasets. It is not practical for individual dataset managers to determine which standards are best to apply to their dataset as this could impact accessibility and interoperability. Instead, they need to work with data custodians across interrelated communities and, in partnership with the data repository, the international scientific community to determine the most useful approach. For the data repository, this approach is essential to enable different disciplines and research communities to invoke new forms of analysis and discovery in an increasingly complex data-rich environment. Driven by the heterogeneity of Earth and environmental datasets, NCI developed a Data Quality/Data Assurance Strategy to ensure consistency is maintained within and across all datasets, as well as functionality testing to ensure smooth interoperability between products, tools, and services. This is particularly so for collections that contain data generated from multiple data acquisition campaigns, often using instruments and models that have evolved over time. By implementing the NCI Data Quality Strategy we have seen progressive improvement in the integration and quality of the datasets across the different subject domains, and through this, the ease by which the users can access data from this major data infrastructure. By both adhering to international standards and also contributing to extensions of these standards, data from the NCI NERDIP platform can be federated with data from other globally distributed data repositories and infrastructures. The NCI approach builds on our experience working with the astronomy and climate science communities, which have been internationally coordinating such interoperability standards within their disciplines for some years. The results of our work so far demonstrate more could be done in the Earth science, solid earth and environmental communities, particularly through establishing better linkages between international/national community efforts such as EPOS, ENVRIplus, EarthCube, AuScope and the Research Data Alliance.
Development Of International Data Standards For The COSMOS/PEER-LL Virtual Data Center
NASA Astrophysics Data System (ADS)
Swift, J. N.
2005-12-01
The COSMOS -PEER Lifelines Project 2L02 completed a Pilot Geotechnical Virtual Data Center (GVDC) system capable of both archiving geotechnical data and of disseminating data from multiple linked geotechnical databases. The Pilot GVDC system links geotechnical databases of four organizations: the California Geological Survey, Caltrans, PG&E, and the U. S. Geological Survey The System was presented and reviewed in the COSMOS-PEER Lifelines workshop on June 21 - 23, 2004, which was co-sponsored by the Federal Highway Administration (FHWA) and included participation by the United Kingdom Highways Agency (UKHA) , the Association of Geotechnical and Geoenvironmental Specialists in the United Kingdom (AGS), the United States Army Corp of Engineers (USACOE), Caltrans, United States Geological Survey (USGS), California Geological Survey (CGS), a number of state Departments of Transportation (DOTs), county building code officials, and representatives of academic institutions and private sector geotechnical companies. As of February 2005 COSMOS-PEER Lifelines Project 2L03 is currently funded to accomplish the following tasks: 1) expand the Pilot GVDC Geotechnical Data Dictionary and XML Schema to include data definitions and structures to describe in-situ measurements such as shear wave velocity profiles, and additional laboratory geotechnical test types; 2) participate in an international cooperative working group developing a single geotechnical data exchange standard that has broad international acceptance; and 3) upgrade the GVDC system to support corresponding exchange standard data dictionary and schema improvements. The new geophysical data structures being developed will include PS-logs, downhole geophysical logs, cross-hole velocity data, and velocity profiles derived using surface waves. A COSMOS-PEER Lifelines Geophysical Data Dictionary Working Committee constituted of experts in the development of data dictionary standards and experts in the specific data to be captured are presently working on this task. The international geotechnical data dictionary and schema development is a highly collaborative effort funded by a pooled fund study coordinated by state DOTs and FHWA. The technical development of the standards called DIGGS (Data Interchange for Geotechnical and Geoenvironmental Specialists) is lead by a team consisting of representatives from the University of Florida, Department of Civil Engineering (UF), AGS, Construction Industry Research and Information Association (CIRIA), UKHA, Ohio DOT, and COSMOS. The first draft of DIGGS is currently in preparation. A Geotechnical Management System Group (GMS group), composed of representatives from 13 State DOTs, FHWA, US EPA, USACOE, USGS and UKHA, oversees and approves the development of the standards. The ultimate goal of both COSMOS-PEER Lifelines Project 2L03 and the international GMS working group is to produce open and flexible, GML-compliant XML schema-based data structures and data dictionaries for review and approval by DOTs, other public agencies, and the international engineering and geoenvironmental community at large, leading to adoption of internationally accepted geotechnical and geophysical data transfer standards. Establishment of these standards is intended to significantly facilitate the accessibility and exchange of geotechnical information world wide.
Potential GPRS 900/180-MHz and WCDMA 1900-MHz interference to medical devices.
Iskra, Steve; Thomas, Barry W; McKenzie, Ray; Rowley, Jack
2007-10-01
This study compared the potential for interference to medical devices from radio frequency (RF) fields radiated by GSM 900/1800-MHz, general packet radio service (GPRS) 900/1800-MHz, and wideband code division multiple access (WCDMA) 1900-MHz handsets. The study used a balanced half-wave dipole antenna, which was energized with a signal at the standard power level for each technology, and then brought towards the medical device while noting the distance at which interference became apparent. Additional testing was performed with signals that comply with the requirements of the international immunity standard to RF fields, IEC 61000-4-3. The testing provides a sense of the overall interference impact that GPRS and WCDMA (frequency division duplex) may have, relative to current mobile technologies, and to the internationally recognized standard for radiated RF immunity. Ten medical devices were tested: two pulse oximeters, a blood pressure monitor, a patient monitor, a humidifier, three models of cardiac defibrillator, and two models of infusion pump. Our conclusion from this and a related study on consumer devices is that WCDMA handsets are unlikely to be a significant interference threat to medical electronics at typical separation distances.
NASA Technical Reports Server (NTRS)
Gary, G. Allen; Moore, R. L.
2004-01-01
We present observations and an interpretation of a unique multiple-turn spiral flux tube eruption from active region 10030 on 2002 July 15. The TRACE C IV observations clearly show a flux tube that is helical and erupting from within a sheared magnetic field. These observations are interpreted in the context of the breakout model for magnetic field explosions. The initiation of the helix eruption. as determined by a linear backward extrapolation, starts 25 s after the peak of the flare's strongest impulsive spike of microwave gyrosynchrotron radiation early in the flare s explosive phase, implying that the sheared core field is not the site of the initial reconnection. Within the quadrupolar configuration of the active region, the external and internal reconnection sites are identified in each of two consecutive eruptive flares that produce a double coronal mass ejection (CME). The first external breakout reconnection apparently releases an underlying sheared core field and allows it to erupt, leading to internal reconnection in the wake of the erupting helix. This internal reconnection releases the helix and heats the two-ribbon flare. These events lead to the first CME and are followed by a second breakout that initiates a second and larger halo CME. The strong magnetic shear in the region is compatible with the observed rapid proper motion and evolution of the active region. The multiple-turn helix originates from above a sheared-field magnetic inversion line within a filament channel. and starts to erupt only after fast breakout reconnection has started. These observations are counter to the standard flare model and support the breakout model for eruptive flare initiation.
Liu, Yu-Qi; Wang, Yue-Xi; Shi, Nan-Nan; Han, Xue-Jie; Lu, Ai-Ping
2017-05-01
To review the current situation and progress of traditional Chinese medicine (TCM) international standards, standard projects and proposals in International Organization for Standardization (ISO)/ technical committee (TC) 249. ISO/TC 249 standards and standard projects on the ISO website were searched and new standard proposals information were collected from ISO/TC 249 National Mirror Committee in China. Then all the available data were summarized in 5 closely related items, including proposed time, proposed country, assigned working group (WG), current stage and classifification. In ISO/TC 249, there were 2 international standards, 18 standard projects and 24 new standard proposals proposed in 2014. These 44 standard subjects increased year by year since 2011. Twenty-nine of them were proposed by China, 15 were assigned to WG 4, 36 were in preliminary and preparatory stage and 8 were categorized into 4 fifields, 7 groups and sub-groups based on International Classifification Standards. A rapid and steady development of international standardization in TCM can be observed in ISO/TC 249.
NASA Astrophysics Data System (ADS)
Zhu, Xiaoyan; Sun, Jianguo; Hao, Haiping; Wang, Guangji; Hu, Xiaoling; Lv, Hua; Gu, Shenghua; Wu, Xiaoming; Xu, Jinyi
2008-05-01
A rapid and sensitive high performance liquid chromatography-electrospray tandem mass spectrometry (HPLC-ESI-MS/MS) detection was developed for the simultaneous determination of multiple angiotensin type 1 receptor antagonists (AT1RAs) WX472, WX581, 1b and telmisartan in rat plasma for the purpose of high-throughout pharmacokinetic screening. The method was operated under selected reaction monitoring (SRM) mode in the positive ion mode. The analytes and the internal standard (pitavastatin) were extracted from 100 [mu]L rat plasma under acidic conditions by liquid-liquid extraction with ethyl acetate. The analytes and internal standard were baseline separated on a Gemini analytical column (3 [mu]m, 150 mm × 2.0 mm) with the adoption of a gradient elution using acetonitrile and 0.05% aqueous formic acid. The standard curves were linear in the concentration ranges of 4.5-900 ng/mL for WX472, 5-1000 ng/mL for WX581 and 0.5-100 ng/mL for 1b and telmisartan. Intra- and inter-batch precisions (R.S.D.%) were all within 15% and the method assessed a quite good accuracy (R.E.%). Recoveries were found to be >65% for all the compounds and no obvious matrix effects were found. This method has been successfully applied to the high-throughput pharmacokinetic screening study for both cassette dosing and cassette analysis of four compounds to rats. Significant drug-drug interactions were observed after cassette dosing. The study suggested that cassette analysis of pooled samples would be a better choice for the high-throughput pharmacokinetic screening of angiotensin type 1 receptor antagonists.
NASA Astrophysics Data System (ADS)
Prentice, Boone M.; Chumbley, Chad W.; Caprioli, Richard M.
2017-01-01
Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) allows for the visualization of molecular distributions within tissue sections. While providing excellent molecular specificity and spatial information, absolute quantification by MALDI IMS remains challenging. Especially in the low molecular weight region of the spectrum, analysis is complicated by matrix interferences and ionization suppression. Though tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity and improve sensitivity by eliminating chemical noise, typical MALDI MS/MS modalities only scan for a single MS/MS event per laser shot. Herein, we describe TOF/TOF instrumentation that enables multiple fragmentation events to be performed in a single laser shot, allowing the intensity of the analyte to be referenced to the intensity of the internal standard in each laser shot while maintaining the benefits of MS/MS. This approach is illustrated by the quantitative analyses of rifampicin (RIF), an antibiotic used to treat tuberculosis, in pooled human plasma using rifapentine (RPT) as an internal standard. The results show greater than 4-fold improvements in relative standard deviation as well as improved coefficients of determination (R2) and accuracy (>93% quality controls, <9% relative errors). This technology is used as an imaging modality to measure absolute RIF concentrations in liver tissue from an animal dosed in vivo. Each microspot in the quantitative image measures the local RIF concentration in the tissue section, providing absolute pixel-to-pixel quantification from different tissue microenvironments. The average concentration determined by IMS is in agreement with the concentration determined by HPLC-MS/MS, showing a percent difference of 10.6%.
Modulation and Coding for NASA's New Space Communications Architecture
NASA Technical Reports Server (NTRS)
Deutsch, Leslie J.; Stocklin, Frank J.; Rush, John J.
2008-01-01
With the release in 2006 of NASA's Space Communications and Navigation Architecture, the agency defined its vision for the future in these areas. The results reported in this paper help define the myriad communications links included in this architecture through the year 2030. While these results represent the work of multiple NASA Centers and some of the best experts in the Agency, this is only a first step toward developing international telecommunication link standards that will take the world into the next era of space exploration.
Yan, Chao-Gan; Craddock, R. Cameron; Zuo, Xi-Nian; Zang, Yu-Feng; Milham, Michael P.
2014-01-01
As researchers increase their efforts to characterize variations in the functional connectome across studies and individuals, concerns about the many sources of nuisance variation present and their impact on resting state fMRI (R-fMRI) measures continue to grow. Although substantial within-site variation can exist, efforts to aggregate data across multiple sites such as the 1000 Functional Connectomes Project (FCP) and International Neuroimaging Data-sharing Initiative (INDI) datasets amplify these concerns. The present work draws upon standardization approaches commonly used in the microarray gene expression literature, and to a lesser extent recent imaging studies, and compares them with respect to their impact on relationships between common R-fMRI measures and nuisance variables (e.g., imaging site, motion), as well as phenotypic variables of interest (age, sex). Standardization approaches differed with regard to whether they were applied post-hoc vs. during pre-processing, and at the individual vs. group level; additionally they varied in whether they addressed additive effects vs. additive + multiplicative effects, and were parametric vs. non-parametric. While all standardization approaches were effective at reducing undesirable relationships with nuisance variables, post-hoc approaches were generally more effective than global signal regression (GSR). Across approaches, correction for additive effects (global mean) appeared to be more important than for multiplicative effects (global SD) for all R-fMRI measures, with the exception of amplitude of low frequency fluctuations (ALFF). Group-level post-hoc standardizations for mean-centering and variance-standardization were found to be advantageous in their ability to avoid the introduction of artifactual relationships with standardization parameters; though results between individual and group-level post-hoc approaches were highly similar overall. While post-hoc standardization procedures drastically increased test–retest (TRT) reliability for ALFF, modest reductions were observed for other measures after post-hoc standardizations—a phenomena likely attributable to the separation of voxel-wise from global differences among subjects (global mean and SD demonstrated moderate TRT reliability for these measures). Finally, the present work calls into question previous observations of increased anatomical specificity for GSR over mean centering, and draws attention to the near equivalence of global and gray matter signal regression. PMID:23631983
Multi-mesh gear dynamics program evaluation and enhancements
NASA Technical Reports Server (NTRS)
Boyd, L. S.; Pike, J.
1985-01-01
A multiple mesh gear dynamics computer program was continually developed and modified during the last four years. The program can handle epicyclic gear systems as well as single mesh systems with internal, buttress, or helical tooth forms. The following modifications were added under the current funding: variable contact friction, planet cage and ring gear rim flexibility options, user friendly options, dynamic side bands, a speed survey option and the combining of the single and multiple mesh options into one general program. The modified program was evaluated by comparing calculated values to published test data and to test data taken on a Hamilton Standard turboprop reduction gear-box. In general, the correlation between the test data and the analytical data is good.
Pasquali, Matias; Serchi, Tommaso; Planchon, Sebastien; Renaut, Jenny
2017-01-01
The two-dimensional difference gel electrophoresis method is a valuable approach for proteomics. The method, using cyanine fluorescent dyes, allows the co-migration of multiple protein samples in the same gel and their simultaneous detection, thus reducing experimental and analytical time. 2D-DIGE, compared to traditional post-staining 2D-PAGE protocols (e.g., colloidal Coomassie or silver nitrate), provides faster and more reliable gel matching, limiting the impact of gel to gel variation, and allows also a good dynamic range for quantitative comparisons. By the use of internal standards, it is possible to normalize for experimental variations in spot intensities and gel patterns. Here we describe the experimental steps we follow in our routine 2D-DIGE procedure that we then apply to multiple biological questions.
Comparative quantification of human intestinal bacteria based on cPCR and LDR/LCR
Tang, Zhou-Rui; Li, Kai; Zhou, Yu-Xun; Xiao, Zhen-Xian; Xiao, Jun-Hua; Huang, Rui; Gu, Guo-Hao
2012-01-01
AIM: To establish a multiple detection method based on comparative polymerase chain reaction (cPCR) and ligase detection reaction (LDR)/ligase chain reaction (LCR) to quantify the intestinal bacterial components. METHODS: Comparative quantification of 16S rDNAs from different intestinal bacterial components was used to quantify multiple intestinal bacteria. The 16S rDNAs of different bacteria were amplified simultaneously by cPCR. The LDR/LCR was examined to actualize the genotyping and quantification. Two beneficial (Bifidobacterium, Lactobacillus) and three conditionally pathogenic bacteria (Enterococcus, Enterobacterium and Eubacterium) were used in this detection. With cloned standard bacterial 16S rDNAs, standard curves were prepared to validate the quantitative relations between the ratio of original concentrations of two templates and the ratio of the fluorescence signals of their final ligation products. The internal controls were added to monitor the whole detection flow. The quantity ratio between two bacteria was tested. RESULTS: cPCR and LDR revealed obvious linear correlations with standard DNAs, but cPCR and LCR did not. In the sample test, the distributions of the quantity ratio between each two bacterial species were obtained. There were significant differences among these distributions in the total samples. But these distributions of quantity ratio of each two bacteria remained stable among groups divided by age or sex. CONCLUSION: The detection method in this study can be used to conduct multiple intestinal bacteria genotyping and quantification, and to monitor the human intestinal health status as well. PMID:22294830
Comparative quantification of human intestinal bacteria based on cPCR and LDR/LCR.
Tang, Zhou-Rui; Li, Kai; Zhou, Yu-Xun; Xiao, Zhen-Xian; Xiao, Jun-Hua; Huang, Rui; Gu, Guo-Hao
2012-01-21
To establish a multiple detection method based on comparative polymerase chain reaction (cPCR) and ligase detection reaction (LDR)/ligase chain reaction (LCR) to quantify the intestinal bacterial components. Comparative quantification of 16S rDNAs from different intestinal bacterial components was used to quantify multiple intestinal bacteria. The 16S rDNAs of different bacteria were amplified simultaneously by cPCR. The LDR/LCR was examined to actualize the genotyping and quantification. Two beneficial (Bifidobacterium, Lactobacillus) and three conditionally pathogenic bacteria (Enterococcus, Enterobacterium and Eubacterium) were used in this detection. With cloned standard bacterial 16S rDNAs, standard curves were prepared to validate the quantitative relations between the ratio of original concentrations of two templates and the ratio of the fluorescence signals of their final ligation products. The internal controls were added to monitor the whole detection flow. The quantity ratio between two bacteria was tested. cPCR and LDR revealed obvious linear correlations with standard DNAs, but cPCR and LCR did not. In the sample test, the distributions of the quantity ratio between each two bacterial species were obtained. There were significant differences among these distributions in the total samples. But these distributions of quantity ratio of each two bacteria remained stable among groups divided by age or sex. The detection method in this study can be used to conduct multiple intestinal bacteria genotyping and quantification, and to monitor the human intestinal health status as well.
Description of the case mix experienced by chiropractic students during a clinical internship.
Puhl, Aaron A; Reinhart, Christine J; Injeyan, H Stephen; Tibbles, Anthony
2017-10-01
The primary objective of this study was to describe the case mix experienced by chiropractic students during their clinical internship at the Canadian Memorial Chiropractic College. Secondary objectives were to characterize teaching clinic patient populations, assess the similarity to previously published data for practicing chiropractors, and describe the treatment plans being recommended by interns. A prospective, observational study was conducted using a convenience sample of 24 chiropractic interns. Data were collected by interns using a standardized form that was completed for each new patient and each new complaint examined during the 1-year internship. Standardized forms included data regarding patient demographics, complaint characteristics, and treatment recommendations. Data were included for 23 of 24 participating interns, who described 828 patients and a total of 948 unique complaint presentations. Overall, 60% of patients were female, 86% were 18 to 64 years old, and 23% were naive to chiropractic care. Of all presenting complaints, 93% were pain-based, 67% were chronic, 65% included spinal complaints, and 7% presented with red flags; individual interns' experiences were variable and are described. On average, treatment recommendations called for 9.4 visits and often included multimodal treatment approaches, most commonly soft-tissue therapies (91%), home-based active care (84%), and spine manipulation (70%). The findings of this study suggest that patients presenting to CMCC teaching clinics are similar to those reported previously to attend private chiropractic clinics. While all participating interns encountered multiple complex clinical cases, very few had experience with pediatric populations. This study adds to the few that detail the characteristics of patients attending chiropractic teaching clinics; to our knowledge it is the first to describe average case loads of chiropractic interns.
Economics of ingot slicing with an internal diameter saw for low-cost solar cells
NASA Technical Reports Server (NTRS)
Daud, T.; Liu, J. K.; Fiegl, G.
1981-01-01
Slicing of silicon ingots using diamond impregnated internal diameter blade saws has been a standard technology of the semiconductor industry. This paper describes work on improvements to this technology for 10 cm diameter ingot slicing. Ingot rotation, dynamic blade edge control with feedback, mechanized blade dressing and development of thinner blades are the approaches tried. A comparison of the results for wafering with and without ingot rotation is also made. A sensitivity analysis of the major cost elements in wafering is performed for 10 cm diameter ingot and extended to the 15 cm diameter ingot case. Various parameter values such as machine cost, feed rate and consumable materials cost are identified both for single and multiple ingot slicing.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-16
... for Residential Construction in High Wind Areas. ICC 700: National Green Building Standard. The... Codes and Standards that are comprehensive, coordinated, and necessary to regulate the built environment... International Codes and Standards consist of the following: ICC Codes International Building Code. International...
Fiber-channel audio video standard for military and commercial aircraft product lines
NASA Astrophysics Data System (ADS)
Keller, Jack E.
2002-08-01
Fibre channel is an emerging high-speed digital network technology that combines to make inroads into the avionics arena. The suitability of fibre channel for such applications is largely due to its flexibility in these key areas: Network topologies can be configured in point-to-point, arbitrated loop or switched fabric connections. The physical layer supports either copper or fiber optic implementations with a Bit Error Rate of less than 10-12. Multiple Classes of Service are available. Multiple Upper Level Protocols are supported. Multiple high speed data rates offer open ended growth paths providing speed negotiation within a single network. Current speeds supported by commercially available hardware are 1 and 2 Gbps providing effective data rates of 100 and 200 MBps respectively. Such networks lend themselves well to the transport of digital video and audio data. This paper summarizes an ANSI standard currently in the final approval cycle of the InterNational Committee for Information Technology Standardization (INCITS). This standard defines a flexible mechanism whereby digital video, audio and ancillary data are systematically packaged for transport over a fibre channel network. The basic mechanism, called a container, houses audio and video content functionally grouped as elements of the container called objects. Featured in this paper is a specific container mapping called Simple Parametric Digital Video (SPDV) developed particularly to address digital video in avionics systems. SPDV provides pixel-based video with associated ancillary data typically sourced by various sensors to be processed and/or distributed in the cockpit for presentation via high-resolution displays. Also highlighted in this paper is a streamlined Upper Level Protocol (ULP) called Frame Header Control Procedure (FHCP) targeted for avionics systems where the functionality of a more complex ULP is not required.
Watts, Jennifer; Russ, Christiana; St Clair, Nicole E; Uwemedimo, Omolara Thomas
2018-03-28
The number of pediatric Global Health (GH) tracks has more than doubled in less than 10 years. The goal of this study was to describe the characteristics of the pediatric GH tracks to identify commonalities and differences in track structure, funding, and education. In addition, we also identified demographic, institutional, and residency-related factors that were significantly associated with educational offerings and logistical challenges. A cross-sectional survey was electronically administered to pediatric residency programs with GH tracks. Statistical analyses included frequencies to describe GH track characteristics. Fisher's exact tests were used to identify bivariate associations between track structure and funding with educational offerings and logistical challenges. Leaders of 32 pediatric GH tracks (67%) completed the survey. The majority of GH tracks were completed within the 3 years of residency (94%) and identified a GH track director (100%); however, tracks varied in size, enrollment methods, domestic and international partnerships, funding, and evaluations. Dedicated faculty time and GH track budget amounts were associated with more robust infrastructure pertaining to resident international electives, including funding and mentorship. Many tracks did not meet American Academy of Pediatrics recommended standards for clinical international rotations. Despite the presence of multiple similarities among pediatric GH tracks, there are large variations in track structure, education, and funding. The results from this study support the proposal of a formal definition and minimum standards for a GH track, which may provide a framework for quality, consistency, and comparison of GH tracks. Copyright © 2018. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Gan, Yu; Yao, Wang; Myers, Kristin M.; Vink, Joy-Sarah Y.; Wapner, Ronald J.; Hendon, Christine P.
2017-02-01
Uterine cervical collagen fiber network is vital to the normal cervical function in pregnancy. Previously, we presented an orientation estimation method to enable dispersion analysis on a single axial slice of human cervical tissue obtained from the upper half of cervix using optical coherence tomography (OCT). How the collagen fiber network structure changes from the internal os (top of the cervix which meets the uterus) to external os (bottom of cervix which extends into the vagina), remains unknown due to depth penetration limitations of OCT. To establish a collagen fiber directionality "map" of the entire cervix, we imaged serial axial slices of human NP (n=11) and PG (n=2) cervical tissue obtained from the internal to external os using Institutional Review Board approved protocols at Columbia University Medical Center. Each slice was divided into four quadrants. In each quadrant, we stitched multiple overlapped OCT volumes and analyzed the en face images that were parallel to the surface. A pixel-wise directionality map was generated. We analyzed fiber trend by measuring the mean angles and quantified dispersion by calculating the standard deviation of the fiber direction over a region of 400 μm × 400 μm. For the initial four samples, our analysis confirms a circumferential fiber pattern in the outer region of slices at all depths. We found that the standard deviation close to internal os showed no significance to the standard deviation close to external os (p>0.05), indicating comparable dispersion.
26 CFR 1.415(b)-2 - Multiple annuity starting dates. [Reserved
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 5 2010-04-01 2010-04-01 false Multiple annuity starting dates. [Reserved] 1.415(b)-2 Section 1.415(b)-2 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY... Multiple annuity starting dates. [Reserved] ...
Ziegler, Jörg; Abel, Steffen
2014-12-01
A new method for the determination of amino acids is presented. It combines established methods for the derivatization of primary and secondary amino groups with 9-fluorenylmethoxycarbonyl chloride (Fmoc-Cl) with the subsequent amino acid specific detection of the derivatives by LC-ESI-MS/MS using multiple reaction monitoring (MRM). The derivatization proceeds within 5 min, and the resulting amino acid derivatives can be rapidly purified from matrix by solid-phase extraction (SPE) on HR-X resin and separated by reversed-phase HPLC. The Fmoc derivatives yield several amino acid specific fragment ions which opened the possibility to select amino acid specific MRM transitions. The method was applied to all 20 proteinogenic amino acids, and the quantification was performed using L-norvaline as standard. A limit of detection as low as 1 fmol/µl with a linear range of up to 125 pmol/µl could be obtained. Intraday and interday precisions were lower than 10 % relative standard deviations for most of the amino acids. Quantification using L-norvaline as internal standard gave very similar results compared to the quantification using deuterated amino acid as internal standards. Using this protocol, it was possible to record the amino acid profiles of only a single root from Arabidopsis thaliana seedlings and to compare it with the amino acid profiles of 20 dissected root meristems (200 μm).
NASA Astrophysics Data System (ADS)
Carey, William M.
2004-05-01
Recent societal concerns have focused attention on the use of sound as a probe to investigate the oceans and its use in naval sonar applications. The concern is the impact the use of sound may have on marine mammals and fishes. The focus has changed the fields of acoustical oceanography (AO) and underwater acoustics (UW) because of the requirement to communicate between disciplines. Multiple National Research Council publications, Dept. of Navy reports, and several monographs have been written on this subject, and each reveals the importance as well as the misapplication of ASA standards. The ANSI-ASA standards are comprehensive, however not widely applied. The clear definition of standards and recommendations of their use is needed for both scientists and government agencies. Traditionally the U.S. Navy has been responsible for UW standards and calibration; the ANSI-ASA standards have been essential. However, recent changes in the Navy and its laboratory structure may necessitate a more formal recognition of ANSI-ASA standards and perhaps incorporation of UW-AO in the Bureau of Standards. A separate standard for acoustical terminology, reference levels, and notation used in the UW-AO is required. Since the problem is global, a standard should be compatible and cross referenced with the International Standard (CEI/IEC 27-3).
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 2 2011-04-01 2011-04-01 false What are the minimum internal control standards for internal audit for Tier A gaming operations? 542.22 Section 542.22 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are the minimum internal control standards for...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 2 2011-04-01 2011-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for internal audit for Tier B gaming operations? 542.32 Section 542.32 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are the minimum internal control standards for...
Froeling, Martijn; Tax, Chantal M W; Vos, Sjoerd B; Luijten, Peter R; Leemans, Alexander
2017-05-01
In this work, we present the MASSIVE (Multiple Acquisitions for Standardization of Structural Imaging Validation and Evaluation) brain dataset of a single healthy subject, which is intended to facilitate diffusion MRI (dMRI) modeling and methodology development. MRI data of one healthy subject (female, 25 years) were acquired on a clinical 3 Tesla system (Philips Achieva) with an eight-channel head coil. In total, the subject was scanned on 18 different occasions with a total acquisition time of 22.5 h. The dMRI data were acquired with an isotropic resolution of 2.5 mm 3 and distributed over five shells with b-values up to 4000 s/mm 2 and two Cartesian grids with b-values up to 9000 s/mm 2 . The final dataset consists of 8000 dMRI volumes, corresponding B 0 field maps and noise maps for subsets of the dMRI scans, and ten three-dimensional FLAIR, T 1 -, and T 2 -weighted scans. The average signal-to-noise-ratio of the non-diffusion-weighted images was roughly 35. This unique set of in vivo MRI data will provide a robust framework to evaluate novel diffusion processing techniques and to reliably compare different approaches for diffusion modeling. The MASSIVE dataset is made publically available (both unprocessed and processed) on www.massive-data.org. Magn Reson Med 77:1797-1809, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Tsai, Tsung-Heng; Tadesse, Mahlet G.; Di Poto, Cristina; Pannell, Lewis K.; Mechref, Yehia; Wang, Yue; Ressom, Habtom W.
2013-01-01
Motivation: Liquid chromatography-mass spectrometry (LC-MS) has been widely used for profiling expression levels of biomolecules in various ‘-omic’ studies including proteomics, metabolomics and glycomics. Appropriate LC-MS data preprocessing steps are needed to detect true differences between biological groups. Retention time (RT) alignment, which is required to ensure that ion intensity measurements among multiple LC-MS runs are comparable, is one of the most important yet challenging preprocessing steps. Current alignment approaches estimate RT variability using either single chromatograms or detected peaks, but do not simultaneously take into account the complementary information embedded in the entire LC-MS data. Results: We propose a Bayesian alignment model for LC-MS data analysis. The alignment model provides estimates of the RT variability along with uncertainty measures. The model enables integration of multiple sources of information including internal standards and clustered chromatograms in a mathematically rigorous framework. We apply the model to LC-MS metabolomic, proteomic and glycomic data. The performance of the model is evaluated based on ground-truth data, by measuring correlation of variation, RT difference across runs and peak-matching performance. We demonstrate that Bayesian alignment model improves significantly the RT alignment performance through appropriate integration of relevant information. Availability and implementation: MATLAB code, raw and preprocessed LC-MS data are available at http://omics.georgetown.edu/alignLCMS.html Contact: hwr@georgetown.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:24013927
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-21
... National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines AGENCY: Environmental Protection... Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance...
78 FR 63873 - Minimum Internal Control Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-25
... Internal Control Standards AGENCY: National Indian Gaming Commission, Interior. ACTION: Final rule. SUMMARY: The National Indian Gaming Commission (NIGC) amends its minimum internal control standards for Class... Internal Control Standards. 64 FR 590. The rule added a new part to the Commission's regulations...
78 FR 11793 - Minimum Internal Control Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-20
... Internal Control Standards AGENCY: National Indian Gaming Commission. ACTION: Proposed rule. SUMMARY: The National Indian Gaming Commission (NIGC) proposes to amend its minimum internal control standards for Class... NIGC published a final rule in the Federal Register called Minimum Internal Control Standards. 64 FR...
International Standards for Genomes, Transcriptomes, and Metagenomes
Mason, Christopher E.; Afshinnekoo, Ebrahim; Tighe, Scott; Wu, Shixiu; Levy, Shawn
2017-01-01
Challenges and biases in preparing, characterizing, and sequencing DNA and RNA can have significant impacts on research in genomics across all kingdoms of life, including experiments in single-cells, RNA profiling, and metagenomics (across multiple genomes). Technical artifacts and contamination can arise at each point of sample manipulation, extraction, sequencing, and analysis. Thus, the measurement and benchmarking of these potential sources of error are of paramount importance as next-generation sequencing (NGS) projects become more global and ubiquitous. Fortunately, a variety of methods, standards, and technologies have recently emerged that improve measurements in genomics and sequencing, from the initial input material to the computational pipelines that process and annotate the data. Here we review current standards and their applications in genomics, including whole genomes, transcriptomes, mixed genomic samples (metagenomes), and the modified bases within each (epigenomes and epitranscriptomes). These standards, tools, and metrics are critical for quantifying the accuracy of NGS methods, which will be essential for robust approaches in clinical genomics and precision medicine. PMID:28337071
Deans, Zandra C; Costa, Jose Luis; Cree, Ian; Dequeker, Els; Edsjö, Anders; Henderson, Shirley; Hummel, Michael; Ligtenberg, Marjolijn Jl; Loddo, Marco; Machado, Jose Carlos; Marchetti, Antonio; Marquis, Katherine; Mason, Joanne; Normanno, Nicola; Rouleau, Etienne; Schuuring, Ed; Snelson, Keeda-Marie; Thunnissen, Erik; Tops, Bastiaan; Williams, Gareth; van Krieken, Han; Hall, Jacqueline A
2017-01-01
The clinical demand for mutation detection within multiple genes from a single tumour sample requires molecular diagnostic laboratories to develop rapid, high-throughput, highly sensitive, accurate and parallel testing within tight budget constraints. To meet this demand, many laboratories employ next-generation sequencing (NGS) based on small amplicons. Building on existing publications and general guidance for the clinical use of NGS and learnings from germline testing, the following guidelines establish consensus standards for somatic diagnostic testing, specifically for identifying and reporting mutations in solid tumours. These guidelines cover the testing strategy, implementation of testing within clinical service, sample requirements, data analysis and reporting of results. In conjunction with appropriate staff training and international standards for laboratory testing, these consensus standards for the use of NGS in molecular pathology of solid tumours will assist laboratories in implementing NGS in clinical services.
Investigation of Coatings Which Prevent Molten Aluminum/Water Explosions
NASA Astrophysics Data System (ADS)
León, D. D.; Richter, R. T.; Levendusky, T. L.
The Aluminum Association contracted Alcoa in 1995 to identify and test new protective coatings for casting pits as a replacement for Porter International's 7001 (Tarset Standard). Three new coatings have been identified through a series of selection criteria including: 1) A standardized splash test used to evaluate personal protective clothing, 2) An industry-standard molten metal explosion test, 3) A multiple-exposure test to measure durability, and 4) An external shock impact test. The results of this program will be reviewed. This study only tested protective coatings at the "in-service cure time", as defined by the manufacturer. These curing times can be excessive for a production casting facility. The Aluminum Association has contracted Alcoa in a second program to investigate the effect of reduced cure times on adhesion and their effectiveness in preventing molten metal/water explosions. A status update of this new two year program is provided.
77 FR 32444 - Minimum Internal Control Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-01
... Internal Control Standards AGENCY: National Indian Gaming Commission. ACTION: Proposed rule. SUMMARY: The National Indian Gaming Commission (NIGC) proposes to amend its minimum internal control standards for Class... the Federal Register called Minimum Internal Control Standards. 64 FR 590. The rule added a new part...
A Systems Approach to Designing Effective Clinical Trials Using Simulations
Fusaro, Vincent A.; Patil, Prasad; Chi, Chih-Lin; Contant, Charles F.; Tonellato, Peter J.
2013-01-01
Background Pharmacogenetics in warfarin clinical trials have failed to show a significant benefit compared to standard clinical therapy. This study demonstrates a computational framework to systematically evaluate pre-clinical trial design of target population, pharmacogenetic algorithms, and dosing protocols to optimize primary outcomes. Methods and Results We programmatically created an end-to-end framework that systematically evaluates warfarin clinical trial designs. The framework includes options to create a patient population, multiple dosing strategies including genetic-based and non-genetic clinical-based, multiple dose adjustment protocols, pharmacokinetic/pharmacodynamics (PK/PD) modeling and international normalization ratio (INR) prediction, as well as various types of outcome measures. We validated the framework by conducting 1,000 simulations of the CoumaGen clinical trial primary endpoints. The simulation predicted a mean time in therapeutic range (TTR) of 70.6% and 72.2% (P = 0.47) in the standard and pharmacogenetic arms, respectively. Then, we evaluated another dosing protocol under the same original conditions and found a significant difference in TTR between the pharmacogenetic and standard arm (78.8% vs. 73.8%; P = 0.0065), respectively. Conclusions We demonstrate that this simulation framework is useful in the pre-clinical assessment phase to study and evaluate design options and provide evidence to optimize the clinical trial for patient efficacy and reduced risk. PMID:23261867
Bate, Roger; Mathur, Aparna; Lever, Harry M; Thakur, Dinesh; Graedon, Joe; Cooperman, Tod; Mason, Preston; Fox, Erin R
2016-03-01
The regulations for assessing the quality of generic drugs and their bioequivalence to innovator products are outdated and need to be substantially modernized. There are multiple reasons why these changes are needed, including: (i) the regulations remain largely unchanged since the passage of the Hatch-Waxman Act in 1984; (ii) medication therapies have become substantially more complex over the three decades since the passage of the Act; (iii) a switch from an innovator drug to a generic drug, or switching from one generic to another, is not a benign process - there is substantial clinical professional judgment involved and in some instances these decisions should be better informed; and (iv) pharmaceutical ingredients for finished products, whether innovator or generic, are from multiple sources of supply, adding variability in their production, and which may not be accounted for in specification tolerances. When these elements are viewed together, they clearly suggest that more transparency of responsible manufacturers in product labels and updated standards for bioequivalence are required. Copyright © 2015 Elsevier Ltd. All rights reserved.
Payne, Deborah A; Baluchova, Katarina; Peoc'h, Katell H; van Schaik, Ron H N; Chan, K C Allen; Maekawa, Masato; Mamotte, Cyril; Russomando, Graciela; Rousseau, François; Ahmad-Nejad, Parviz
2017-04-01
Multiple organizations produce guidance documents that provide opportunities to harmonize quality practices for diagnostic testing. The International Organization for Standardization ISO 15189 standard addresses requirements for quality in management and technical aspects of the clinical laboratory. One technical aspect addresses the complexities of the pre-examination phase prior to diagnostic testing. The Committee for Molecular Diagnostics of the International Federation for Clinical Chemistry and Laboratory Medicine (also known as, IFCC C-MD) conducted a survey of international molecular laboratories and determined ISO 15189 to be the most referenced guidance document. In this review, the IFCC C-MD provides case-based examples illustrating the value of select pre-examination processes as these processes relate to molecular diagnostic testing. Case-based examples in infectious disease, oncology, inherited disease and pharmacogenomics address the utility of: 1) providing information to patients and users, 2) designing requisition forms, 3) obtaining informed consent and 4) maintaining sample integrity prior to testing. The pre-examination phase requires extensive and consistent communication between the laboratory, the healthcare provider and the end user. The clinical vignettes presented in this paper illustrate the value of applying select ISO 15189 recommendations for general laboratory to the more specialized area of Molecular Diagnostics. Copyright © 2016 Elsevier B.V. All rights reserved.
Yokoyama, Takaomi D; Suzuki, Toshihiro; Kon, Yoshiaki; Hirata, Takafumi
2011-12-01
We have developed a new calibration technique for multielement determination and U-Pb dating of zircon samples using laser ablation-inductively coupled plasma mass spectrometry (ICPMS) coupled with galvanometric optics. With the galvanometric optics, laser ablation of two or more sample materials could be achieved in very short time intervals (~10 ms). The resulting sample aerosols released from different ablation pits or different solid samples were mixed and homogenized within the sample cell and then transported into the ICP ion source. Multiple spot laser ablation enables spiking of analytes or internal standard elements directly into the solid samples, and therefore the standard addition calibration method can be applied for the determination of trace elements in solid samples. In this study, we have measured the rare earth element (REE) abundances of two zircon samples (Nancy 91500 and Prešovice) based on the standard addition technique, using a direct spiking of analytes through a multispot laser ablation of the glass standard material (NIST SRM612). The resulting REE abundance data show good agreement with previously reported values within analytical uncertainties achieved in this study (10% for most elements). Our experiments demonstrated that nonspectroscopic interferences on 14 REEs could be significantly reduced by the standard addition technique employed here. Another advantage of galvanometric devices is the accumulation of sample aerosol released from multiple spots. In this study we have measured the U-Pb age of a zircon sample (LMR) using an accumulation of sample aerosols released from 10 separate ablation pits of low diameters (~8 μm). The resulting (238)U-(206)Pb age data for the LMR zircons was 369 ± 64 Ma, which is in good agreement with previously reported age data (367.6 ± 1.5 Ma). (1) The data obtained here clearly demonstrate that the multiple spot laser ablation-ICPMS technique can become a powerful approach for elemental and isotopic ratio measurements in solid materials.
Waldman, Amy; Ghezzi, Angelo; Bar-Or, Amit; Mikaeloff, Yann; Tardieu, Marc; Banwell, Brenda
2015-01-01
The clinical features, diagnostic challenges, neuroimaging appearance, therapeutic options, and pathobiological research progress in childhood—and adolescent—onset multiple sclerosis have been informed by many new insights in the past 7 years. National programmes in several countries, collaborative research efforts, and an established international paediatric multiple sclerosis study group have contributed to revised clinical diagnostic definitions, identified clinical features of multiple sclerosis that differ by age of onset, and made recommendations regarding the treatment of paediatric multiple sclerosis. The relative risks conveyed by genetic and environmental factors to paediatric multiple sclerosis have been the subject of several large cohort studies. MRI features have been characterised in terms of qualitative descriptions of lesion distribution and applicability of MRI aspects to multiple sclerosis diagnostic criteria, and quantitative studies have assessed total lesion burden and the effect of the disease on global and regional brain volume. Humoral-based and cell-based assays have identified antibodies against myelin, potassium-channel proteins, and T-cell profiles that support an adult-like T-cell repertoire and cellular reactivity against myelin in paediatric patients with multiple sclerosis. Finally, the safety and efficacy of standard first-line therapies in paediatric multiple sclerosis populations are now appreciated in more detail, and consensus views on the future conduct and feasibility of phase 3 trials for new drugs have been proposed. PMID:25142460
Percy, Andrew J; Yang, Juncong; Hardie, Darryl B; Chambers, Andrew G; Tamura-Wells, Jessica; Borchers, Christoph H
2015-06-15
Spurred on by the growing demand for panels of validated disease biomarkers, increasing efforts have focused on advancing qualitative and quantitative tools for more highly multiplexed and sensitive analyses of a multitude of analytes in various human biofluids. In quantitative proteomics, evolving strategies involve the use of the targeted multiple reaction monitoring (MRM) mode of mass spectrometry (MS) with stable isotope-labeled standards (SIS) used for internal normalization. Using that preferred approach with non-invasive urine samples, we have systematically advanced and rigorously assessed the methodology toward the precise quantitation of the largest, multiplexed panel of candidate protein biomarkers in human urine to date. The concentrations of the 136 proteins span >5 orders of magnitude (from 8.6 μg/mL to 25 pg/mL), with average CVs of 8.6% over process triplicate. Detailed here is our quantitative method, the analysis strategy, a feasibility application to prostate cancer samples, and a discussion of the utility of this method in translational studies. Copyright © 2015 Elsevier Inc. All rights reserved.
Richards-Kortum, Rebecca
2015-01-01
It was recently demonstrated that recombinase polymerase amplification (RPA), an isothermal amplification platform for pathogen detection, may be used to quantify DNA sample concentration using a standard curve. In this manuscript, a detailed protocol for developing and implementing a real-time quantitative recombinase polymerase amplification assay (qRPA assay) is provided. Using HIV-1 DNA quantification as an example, the assembly of real-time RPA reactions, the design of an internal positive control (IPC) sequence, and co-amplification of the IPC and target of interest are all described. Instructions and data processing scripts for the construction of a standard curve using data from multiple experiments are provided, which may be used to predict the concentration of unknown samples or assess the performance of the assay. Finally, an alternative method for collecting real-time fluorescence data with a microscope and a stage heater as a step towards developing a point-of-care qRPA assay is described. The protocol and scripts provided may be used for the development of a qRPA assay for any DNA target of interest. PMID:25867513
Crannell, Zachary A; Rohrman, Brittany; Richards-Kortum, Rebecca
2015-03-30
It was recently demonstrated that recombinase polymerase amplification (RPA), an isothermal amplification platform for pathogen detection, may be used to quantify DNA sample concentration using a standard curve. In this manuscript, a detailed protocol for developing and implementing a real-time quantitative recombinase polymerase amplification assay (qRPA assay) is provided. Using HIV-1 DNA quantification as an example, the assembly of real-time RPA reactions, the design of an internal positive control (IPC) sequence, and co-amplification of the IPC and target of interest are all described. Instructions and data processing scripts for the construction of a standard curve using data from multiple experiments are provided, which may be used to predict the concentration of unknown samples or assess the performance of the assay. Finally, an alternative method for collecting real-time fluorescence data with a microscope and a stage heater as a step towards developing a point-of-care qRPA assay is described. The protocol and scripts provided may be used for the development of a qRPA assay for any DNA target of interest.
The Third International Standard for Corticotrophin
Bangham, D. R.; Mussett, M. V.; Stack-Dunne, M. P.
1962-01-01
At its meeting in September 1957, the WHO Expert Committee on Biological Standardization agreed with the recommendation of the International Conference on Corticotrophin, held in July 1957, that a new international standard for corticotrophin should be set up, since the Second International Standard was made from crude material and was unsuitable for the assay of the purer preparations of corticotrophin now in general clinical use. In this paper, the authors describe the steps taken to establish the Third International Standard for Corticotrophin, from the preparation and international collaborative assay of the new material to the choice of the ”subcutaneous assay” for deriving the potency. The clinical and pharmacological implications of this choice are discussed. Since the preparation, characterization and exact quantitative assay of standards for corticotrophin are so difficult, several batches of approximately 3500 ampoules were prepared in a similar way from the same material to serve as an international Working Standard. Samples from two batches were included in the collaborative assay and found to have the same potency as the Third Standard. Sufficient ampoules of the Working Standard are available for use as national and laboratory standards. PMID:13966359
FOREWORD: Special issue on mass
NASA Astrophysics Data System (ADS)
Gläser, Michael
2003-12-01
This special issue is intended to present a review of mass standards, mass determination and the efforts to replace the international prototype of the kilogram by a new definition of the kilogram based on a fundamental constant of physics. Mass is a quantity that is familiar to everybody primarily for its importance in commerce. It is not only one of the traditional quantities of metrology but also of science in general. The unit of mass has always been based on a material object and, since 1889, on the international prototype of the kilogram. The mass of any standard weight is derived from this prototype by a cascade of comparison measurements using balances. The sources of uncertainty of the mass of a standard depend upon the circumstances of the weighing process and the long-term instabilities of the intermediate standards. The international prototype—its mass is one kilogram by definition—may also suffer from instabilities or drifts in time, but until now it has not been possible to check this by comparison with a fundamental constant in physics. Repeated verifications of some 40 or so national prototypes of the members of the Metre Convention have shown significant drifts with an average of about 50 µg within 100 years, a fact that casts doubt on the stability of the international prototype itself. Experiments have been underway for about 30 years on linking fundamental constants such as the Avogadro constant or, correspondingly, the atomic mass unit and Planck's constant to the kilogram. Relative uncertainties of the order of 10-7 have been reached today, still one order of magnitude too large for monitoring the stability of the international prototype or for a new definition. The first article of this special issue gives information on the international and the national prototypes of the kilogram, its material, manufacture, cleaning procedures, stability investigations and the periodic verifications of national prototypes. The next article describes methods for determining the mass of multiples and submultiples of the kilogram. In practice, mass standards in the range from one milligram up to several thousands of kilograms are used for the mass determination of commercial objects or for the calibration of weighing instruments. The determination of the mass of multiples and submultiples of the kilogram is a procedure that links such mass standards to the kilogram by a number of—mostly redundant—weighing processes and mathematical procedures that result in the values and the uncertainties of the standards involved. The reproducibility of E-class weights is the topic of the next article. Classification of weights is defined in an international recommendation for legal metrology and is carried over into the national regulations of most countries. E-class weights are at the highest level in this context. Reproducibility is related to the instability of mass standards within some time interval. Corresponding observations and discussions of the results are reported. As already mentioned, weighing is an important source of the uncertainty of a mass standard. The requirements on weighing in legal metrology are discussed in the following article. It refers to the project of a new international recommendation for weights (revised OIML R 111) that describes procedures for mass determination and for testing the properties of weights according to the stated requirements for the different classes. The instability of mass standards is mostly due to surface contamination. A review of the stability of platinum-iridium and stainless-steel standards and their surface contamination is presented in the next article. It gives a comprehensive overview of published data and investigations on this topic. Magnetic weights interact with the magnetic field generated by a balance. A change in the balance indication is the consequence if certain limits are exceeded. Magnetic properties of weights, their measurements and magnetic interactions between weights and balances constitute the theme of the next article. After an introduction to the theoretical aspects of magnetic fields and magnetic forces, different measurement methods, international comparisons in this field, modelling the interacting forces and finally the impact on the new international recommendation for weights are presented. The moving-coil Watt balance and the superconducting magnetic levitation experiment are two of the experiments aimed at redefining the kilogram. 'Tracing Planck's constant to the kilogram by electromechanical methods' is the title of the corresponding article. It describes the principles of these experiments and reviews the efforts and results achieved at present in the laboratories concerned. Another approach to redefining the kilogram is reviewed in the article entitled 'Tracing the definition of the kilogram to the Avogadro constant using a silicon single crystal'. This approach is performed in a worldwide collaboration coordinated by the Working Group on the Avogadro Constant of the CIPM Consultative Committee for Mass and related quantities. An experiment for determining the atomic mass unit by ion accumulation follows a straightforward way for determining the mass of an atom by collecting ions, weighing and 'counting' them by measuring their total charge. This article reports on a 'third' way of redefining the kilogram. This approach is followed by only one laboratory and it is still at an early stage compared with the uncertainties already achieved by the other ones.
78 FR 21060 - Appeal Proceedings Before the Commission
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-09
... adoption of alternate standards from those required by the Commission's minimum internal control standards... adoption of alternate standards from those required by the Commission's minimum internal control standards... TGRAs' adoption of alternate standards from those required by the Commission's minimum internal control...
26 CFR 26.2653-1 - Taxation of multiple skips.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 14 2010-04-01 2010-04-01 false Taxation of multiple skips. 26.2653-1 Section 26.2653-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) ESTATE...-1 Taxation of multiple skips. (a) General rule. If property is held in trust immediately after a GST...
26 CFR 26.2653-1 - Taxation of multiple skips.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 14 2011-04-01 2010-04-01 true Taxation of multiple skips. 26.2653-1 Section 26.2653-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) ESTATE AND... Taxation of multiple skips. (a) General rule. If property is held in trust immediately after a GST, solely...
Laboratory information management system: an example of international cooperation in Namibia.
Colangeli, Patrizia; Ferrilli, Monica; Quaranta, Fabrizio; Malizia, Elio; Mbulu, Rosa-Stella; Mukete, Esther; Iipumbu, Lukas; Kamhulu, Anna; Tjipura-Zaire, Georgina; Di Francesco, Cesare; Lelli, Rossella; Scacchia, Massimo
2012-01-01
The authors describe the project undertaken by the Istituto G. Caporale to provide a laboratory information management system (LIMS) to the Central Veterinary Laboratory (CVL) in Windhoek, Namibia. This robust laboratory management tool satisfies Namibia's information obligations under international quality standard ISO 17025:2005. The Laboratory Information Management System (LIMS) for Africa was designed to collect and manage all necessary information on samples, tests and test results. The system involves the entry of sample data on arrival, as required by Namibian sampling plans, the tracking of samples through the various sections of the CVL, the collection of test results, generation of test reports and monitoring of outbreaks through data interrogation functions, eliminating multiple registrations of the same data on paper records. It is a fundamental component of the Namibian veterinary information system.
Hewavitharana, Amitha K; Abu Kassim, Nur Sofiah; Shaw, Paul Nicholas
2018-06-08
With mass spectrometric detection in liquid chromatography, co-eluting impurities affect the analyte response due to ion suppression/enhancement. Internal standard calibration method, using co-eluting stable isotope labelled analogue of each analyte as the internal standard, is the most appropriate technique available to correct for these matrix effects. However, this technique is not without drawbacks, proved to be expensive because separate internal standard for each analyte is required, and the labelled compounds are expensive or require synthesising. Traditionally, standard addition method has been used to overcome the matrix effects in atomic spectroscopy and was a well-established method. This paper proposes the same for mass spectrometric detection, and demonstrates that the results are comparable to those with the internal standard method using labelled analogues, for vitamin D assay. As conventional standard addition procedure does not address procedural errors, we propose the inclusion of an additional internal standard (not co-eluting). Recoveries determined on human serum samples show that the proposed method of standard addition yields more accurate results than the internal standardisation using stable isotope labelled analogues. The precision of the proposed method of standard addition is superior to the conventional standard addition method. Copyright © 2018 Elsevier B.V. All rights reserved.
Using FTIR-ATR Spectroscopy to Teach the Internal Standard Method
ERIC Educational Resources Information Center
Bellamy, Michael K.
2010-01-01
The internal standard method is widely applied in quantitative analyses. However, most analytical chemistry textbooks either omit this topic or only provide examples of a single-point internal standardization. An experiment designed to teach students how to prepare an internal standard calibration curve is described. The experiment is a modified…
Internal jugular vein blood flow in multiple sclerosis patients and matched controls.
Mancini, Marcello; Lanzillo, Roberta; Liuzzi, Raffaele; Di Donato, Orlando; Ragucci, Monica; Monti, Serena; Salvatore, Elena; Morra, Vincenzo Brescia; Salvatore, Marco
2014-01-01
The aim of the study was to investigate the Internal Jugular Veins dynamics using contrast enhanced ultrasonography in Multiple Sclerosis patients, clinically isolated syndrome patients and healthy controls. Contrast enhanced ultrasonography imaging of the Internal Jugular Vein was performed in fifty-eight patients with Multiple Sclerosis, seven clinically isolated syndrome patients and in thirteen healthy controls. Time-intensity curves were quantified using a semi-automated method and compared with clinical disease outcomes. Wash-out parameters were calculated and six Time-intensity curves shapes were created. Significantly reduction of wash-out rate in Internal Jugular Veins was detected in Multiple Sclerosis patients compared to healthy controls [22.2% (2.7%-65.9%) vs. 33.4% (16.2%-76.8%); P<0.005]. Internal Jugular Vein enhancement was heterogeneous in patients with Multiple Sclerosis and consisted of slow wash-out Time-intensity curves shapes, compared with almost only one type of Time-intensity curves shape in control subjects that correspond to fast enhancement and fast wash-out. The vein wash-in parameters were similar in Multiple Sclerosis group compared with controls. A significant correlation was found between Internal Jugular Vein wash-out and level of disability (R = -0.402, p<0.05). Contrast enhanced ultrasonography of the Internal Jugular Vein with time intensity curve analysis revealed alterations of cerebral venous outflow in Multiple Sclerosis patients, however mechanisms that determine this condition remains unclear.
Anand, K; Saini, Ks; Chopra, Y; Binod, Sk
2010-07-01
'Medical Devices' include everything from highly sophisticated, computerized, medical equipment, right down to simple wooden tongue depressors. Regulations embody the public expectations for how buildings and facilities are expected to perform and as such represent public policy. Regulators, who develop and enforce regulations, are empowered to act in the public's interest to set this policy and are ultimately responsible to the public in this regard. Standardization contributes to the basic infrastructure that underpins society including health and environment, while promoting sustainability and good regulatory practice. The international organizations that produce International Standards are the International Electrotechnical Commission (IEC), the International Organization for Standardization (ISO), and the International Telecommunication Union (ITU). With the increasing globalization of markets, International Standards (as opposed to regional or national standards) have become critical to the trading process, ensuring a level playing field for exports, and ensuring that imports meet the internationally recognized levels of performance and safety. The development of standards is done in response to sectors and stakeholders that express a clearly established need for them. An industry sector or other stakeholder group typically communicates its requirement for standards to one of the national members. To be accepted for development, a proposed work item must receive a majority support of the participating members, who verify the global relevance of the proposed item. The regulatory authority (RA) should provide a method for the recognition of international voluntary standards and for public notification of such recognition. The process of recognition may vary from country to country. Recognition may occur by periodic publication of lists of standards that a regulatory authority has found will meet the Essential Principles. In conclusion, International standards, such as, basic standards, group standards, and product standards, are a tool for harmonizing regulatory processes, to assure the safety, quality, and performance of medical devices. Standards represent the opinion of experts from all interested parties, including industry, regulators, users, and others.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-26
... for Residential Construction in High Wind Regions. ICC 700: National Green Building Standard The..., coordinated, and necessary to regulate the built environment. Federal agencies frequently use these codes and... International Codes and Standards consist of the following: ICC Codes International Building Code. International...
Nelson, Michael A; Bedner, Mary; Lang, Brian E; Toman, Blaza; Lippa, Katrice A
2015-11-01
Given the critical role of pure, organic compound primary reference standards used to characterize and certify chemical Certified Reference Materials (CRMs), it is essential that associated mass purity assessments be fit-for-purpose, represented by an appropriate uncertainty interval, and metrologically sound. The mass fraction purities (% g/g) of 25-hydroxyvitamin D (25(OH)D) reference standards used to produce and certify values for clinical vitamin D metabolite CRMs were investigated by multiple orthogonal quantitative measurement techniques. Quantitative (1)H-nuclear magnetic resonance spectroscopy (qNMR) was performed to establish traceability of these materials to the International System of Units (SI) and to directly assess the principal analyte species. The 25(OH)D standards contained volatile and water impurities, as well as structurally-related impurities that are difficult to observe by chromatographic methods or to distinguish from the principal 25(OH)D species by one-dimensional NMR. These impurities have the potential to introduce significant biases to purity investigations in which a limited number of measurands are quantified. Combining complementary information from multiple analytical methods, using both direct and indirect measurement techniques, enabled mitigation of these biases. Purities of 25(OH)D reference standards and associated uncertainties were determined using frequentist and Bayesian statistical models to combine data acquired via qNMR, liquid chromatography with UV absorbance and atmospheric pressure-chemical ionization mass spectrometric detection (LC-UV, LC-ACPI-MS), thermogravimetric analysis (TGA), and Karl Fischer (KF) titration.
Evans, D. G.; Perkins, F. T.
1963-01-01
The Fifth International Standard Gas-Gangrene Antitoxin (Perfringens) (Clostridium welchii Type A Antitoxin) was prepared from serum from immunized horses. It was freeze-dried in ampoules each containing 1 ml. Seven laboratories collaborated in assaying its potency in terms of the Fourth International Standard by the intravenous inoculation of mice. The geometric mean value, taking the results of all the laboratories, was 270 International Units per ampoule and the maximum variation between laboratories was 15%. In vitro (lecithinase) tests were also done by three laboratories, giving an average of 261 International Units per ampoule. The dry weight contents of ampoules, determined in three laboratories, varied by less than 3%, with an average of 90.35 mg per ampoule. The standard was stable for 120 hours at 56°C. Each ampoule of the Fifth International Standard for Gas-Gangrene Antitoxin (Perfringens) contains 270 International Units, and one International Unit is contained in 0.3346 mg of the International Standard. PMID:14107745
The second international standard for polymyxin B.
Lightbown, J W; Thomas, A H; Grab, B; Outschoorn, A S
1973-01-01
Since supplies of the first International Standard for Polymyxin B were exhausted, it was replaced by a second international standard the potency of which was estimated from the results of a collaborative assay carried out by 5 laboratories in 4 countries. The wide variations in the results probably resulted from difficulties experienced in handling the first international standard. The potency finally agreed upon by the collaborating laboratories, on the basis of the overall mean values obtained after rejection of the most discrepant assays, was 8 403 IU/mg. That value was accepted by the WHO Expert Committee on Biological Standardization (1970), which consequently defined the International Unit of polymyxin B as the activity contained in 0.000119 mg of the second international standard.
The second international standard for polymyxin B*
Lightbown, J. W.; Thomas, A. H.; Grab, B.; Outschoorn, A. S.
1973-01-01
Since supplies of the first International Standard for Polymyxin B were exhausted, it was replaced by a second international standard the potency of which was estimated from the results of a collaborative assay carried out by 5 laboratories in 4 countries. The wide variations in the results probably resulted from difficulties experienced in handling the first international standard. The potency finally agreed upon by the collaborating laboratories, on the basis of the overall mean values obtained after rejection of the most discrepant assays, was 8 403 IU/mg. That value was accepted by the WHO Expert Committee on Biological Standardization (1970), which consequently defined the International Unit of polymyxin B as the activity contained in 0.000119 mg of the second international standard. PMID:4350877
Salerno, Stephen M; Arnett, Michael V; Domanski, Jeremy P
2009-01-01
Prior research on reducing variation in housestaff handoff procedures have depended on proprietary checkout software. Use of low-technology standardization techniques has not been widely studied. We wished to determine if standardizing the process of intern sign-out using low-technology sign-out tools could reduce perception of errors and missing handoff data. We conducted a pre-post prospective study of a cohort of 34 interns on a general internal medicine ward. Night interns coming off duty and day interns reassuming care were surveyed on their perception of erroneous sign-out data, mistakes made by the night intern overnight, and occurrences unanticipated by sign-out. Trainee satisfaction with the sign-out process was assessed with a 5-point Likert survey. There were 399 intern surveys performed 8 weeks before and 6 weeks after the introduction of a standardized sign-out form. The response rate was 95% for the night interns and 70% for the interns reassuming care in the morning. After the standardized form was introduced, night interns were significantly (p < .003) less likely to detect missing sign-out data including missing important diseases, contingency plans, or medications. Standardized sign-out did not significantly alter the frequency of dropped tasks or missed lab and X-ray data as perceived by the night intern. However, the day teams thought there were significantly less perceived errors on the part of the night intern (p = .001) after introduction of the standardized sign-out sheet. There was no difference in mean Likert scores of resident satisfaction with sign-out before and after the intervention. Standardized written sign-out sheets significantly improve the completeness and effectiveness of handoffs between night and day interns. Further research is needed to determine if these process improvements are related to better patient outcomes.
Gong, Zheng; Chen, Tianrun; Ratilal, Purnima; Makris, Nicholas C
2013-11-01
An analytical model derived from normal mode theory for the accumulated effects of range-dependent multiple forward scattering is applied to estimate the temporal coherence of the acoustic field forward propagated through a continental-shelf waveguide containing random three-dimensional internal waves. The modeled coherence time scale of narrow band low-frequency acoustic field fluctuations after propagating through a continental-shelf waveguide is shown to decay with a power-law of range to the -1/2 beyond roughly 1 km, decrease with increasing internal wave energy, to be consistent with measured acoustic coherence time scales. The model should provide a useful prediction of the acoustic coherence time scale as a function of internal wave energy in continental-shelf environments. The acoustic coherence time scale is an important parameter in remote sensing applications because it determines (i) the time window within which standard coherent processing such as matched filtering may be conducted, and (ii) the number of statistically independent fluctuations in a given measurement period that determines the variance reduction possible by stationary averaging.
Dong, Shuya; He, Jiao; Hou, Huiping; Shuai, Yaping; Wang, Qi; Yang, Wenling; Sun, Zheng; Li, Qing; Bi, Kaishun; Liu, Ran
2017-12-01
A novel, improved, and comprehensive method for quality evaluation and discrimination of Herba Leonuri has been developed and validated based on normal- and reversed-phase chromatographic methods. To identify Herba Leonuri, normal- and reversed-phase high-performance thin-layer chromatography fingerprints were obtained by comparing the colors and R f values of the bands, and reversed-phase high-performance liquid chromatography fingerprints were obtained by using an Agilent Poroshell 120 SB-C18 within 28 min. By similarity analysis and hierarchical clustering analysis, we show that there are similar chromatographic patterns in Herba Leonuri samples, but significant differences in counterfeits and variants. To quantify the bio-active components of Herba Leonuri, reversed-phase high-performance liquid chromatography was performed to analyze syringate, leonurine, quercetin-3-O-robiniaglycoside, hyperoside, rutin, isoquercitrin, wogonin, and genkwanin simultaneously by single standard to determine multi-components method with rutin as internal standard. Meanwhile, normal-phase high-performance liquid chromatography was performed by using an Agilent ZORBAX HILIC Plus within 6 min to determine trigonelline and stachydrine using trigonelline as internal standard. Innovatively, among these compounds, bio-active components of quercetin-3-O-robiniaglycoside and trigonelline were first determined in Herba Leonuri. In general, the method integrating multi-chromatographic analyses offered an efficient way for the standardization and identification of Herba Leonuri. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Basu, Sankha S; Mesaros, Clementina; Gelhaus, Stacy L; Blair, Ian A
2011-02-15
Stable isotope dilution mass spectrometry (MS) represents the gold standard for quantification of endogenously formed cellular metabolites. Although coenzyme A (CoA) and acyl-CoA thioester derivatives are central players in numerous metabolic pathways, the lack of a commercially available isotopically labeled CoA limits the development of rigorous MS-based methods. In this study, we adapted stable isotope labeling by amino acids in cell culture (SILAC) methodology to biosynthetically generate stable isotope labeled CoA and thioester analogues for use as internal standards in liquid chromatography/multiple reaction monitoring mass spectrometry (LC/MRM-MS) assays. This was accomplished by incubating murine hepatocytes (Hepa 1c1c7) in media in which pantothenate (a precursor of CoA) was replaced with [(13)C(3)(15)N(1)]-pantothenate. Efficient incorporation into various CoA species was optimized to >99% [(13)C(3)(15)N(1)]-pantothenate after three passages of the murine cells in culture. Charcoal-dextran-stripped fetal bovine serum (FBS) was found to be more efficient for serum supplementation than dialyzed or undialyzed FBS, due to lower contaminating unlabeled pantothenate content. Stable isotope labeled CoA species were extracted and utilized as internal standards for CoA thioester analysis in cell culture models. This methodology of stable isotope labeling by essential nutrients in cell culture (SILEC) can serve as a paradigm for using vitamins and other essential nutrients to generate stable isotope standards that cannot be readily synthesized.
Spaun, J.; Lyng, J.
1970-01-01
Since 1935 the International Unit for Tetanus Antitoxin has been defined as the activity contained in a certain weight of the first International Standard for Tetanus Antitoxin. As stocks of this standard had become depleted, 11 laboratories in 8 countries were requested to participate in a collaborative assay of a preparation proposed as a replacement. The assay results were analysed and presented to the WHO Expert Committee on Biological Standardization in 1969 which established the preparation studied as the second International Standard for Tetanus Antitoxin and defined the International Unit for Tetanus Antitoxin as the activity contained in 0.03384 mg of the second International Standard for Tetanus Antitoxin. This definition would ensure the continuity of the size of this international unit. The analysis of the collaborative studies also showed that the second International Standard for Tetanus Antitoxin has suitable properties for use in the flocculation test for the determination of the antigen content of tetanus toxoids in Lf values. The designation Lf-equivalent is described and the problems relating to the use of this term for the expression of results of in vitro assays are analysed in relation to the use of international units for expressing results of in vivo assays. As the second International Standard for Tetanus Antitoxin has an in vivo/in vitro ratio of 1.4, the Lf-equivalent of this antitoxin is 1.4 times less than its unitage. PMID:5310949
25 CFR 542.14 - What are the minimum internal control standards for the cage?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for the cage? 542.14 Section 542.14 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.14 What are the minimum internal control standards for the cage? (a) Computer applications. For...
25 CFR 543.8 - What are the minimum internal control standards for bingo?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for bingo? 543.8 Section 543.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.8 What are the minimum internal control standards for bingo? (a) Supervision....
25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 2 2011-04-01 2011-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...
25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...
25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...
25 CFR 543.8 - What are the minimum internal control standards for bingo?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for bingo? 543.8 Section 543.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.8 What are the minimum internal control standards for bingo? (a) Supervision....
25 CFR 542.17 - What are the minimum internal control standards for complimentary services or items?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for complimentary services or items? 542.17 Section 542.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.17 What are the minimum internal control standards for complimentary...
25 CFR 542.8 - What are the minimum internal control standards for pull tabs?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for pull tabs? 542.8 Section 542.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.8 What are the minimum internal control standards for pull tabs? (a) Computer applications. For...
25 CFR 542.8 - What are the minimum internal control standards for pull tabs?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for pull tabs? 542.8 Section 542.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.8 What are the minimum internal control standards for pull tabs? (a) Computer applications. For...
25 CFR 542.8 - What are the minimum internal control standards for pull tabs?
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 2 2012-04-01 2012-04-01 false What are the minimum internal control standards for pull tabs? 542.8 Section 542.8 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.8 What are the minimum internal control standards for pull tabs? (a) Computer applications. For...
Rule, Geoffrey S; Clark, Zlatuse D; Yue, Bingfang; Rockwood, Alan L
2013-04-16
Stable isotope-labeled internal standards are of great utility in providing accurate quantitation in mass spectrometry (MS). An implicit assumption has been that there is no "cross talk" between signals of the internal standard and the target analyte. In some cases, however, naturally occurring isotopes of the analyte do contribute to the signal of the internal standard. This phenomenon becomes more pronounced for isotopically rich compounds, such as those containing sulfur, chlorine, or bromine, higher molecular weight compounds, and those at high analyte/internal standard concentration ratio. This can create nonlinear calibration behavior that may bias quantitative results. Here, we propose the use of a nonlinear but more accurate fitting of data for these situations that incorporates one or two constants determined experimentally for each analyte/internal standard combination and an adjustable calibration parameter. This fitting provides more accurate quantitation in MS-based assays where contributions from analyte to stable labeled internal standard signal exist. It can also correct for the reverse situation where an analyte is present in the internal standard as an impurity. The practical utility of this approach is described, and by using experimental data, the approach is compared to alternative fits.
NASA Astrophysics Data System (ADS)
Richards, C. J.; Evans, B. J. K.; Wyborn, L. A.; Wang, J.; Trenham, C. E.; Druken, K. A.
2016-12-01
The Australian National Computational Infrastructure (NCI) has ingested over 10PB of national and international environmental, Earth systems science and geophysics reference data onto a single platform to advance high performance data (HPD) techniques that enable interdisciplinary Data-intensive Science. Improved Data Stewardship is critical to evolve both data and data services that support the increasing need for programmatic usability and that prioritises interoperability rather than just traditional data download or portal access. A data platform designed for programmatic access requires quality checked collections that better utilise interoperable data formats and standards. Achieving this involves strategies to meet both the technical and `social' challenges. Aggregating datasets used by different communities and organisations requires satisfying multiple use cases for the broader research community, whilst addressing existing BAU requirements. For NCI, this requires working with data stewards to manage the process of replicating data to the common platform, community representatives and developers to confirm their requirements, and with international peers to better enable globally integrated data communities. It is particularly important to engage with representatives from each community who can work collaboratively to a common goal, as well as capture their community needs, apply quality assurance, determine any barriers to change and to understand priorities. This is critical when managing the aggregation of data collections from multiple producers with different levels of stewardship maturity, technologies and standards, and where organisational barriers can impact the transformation to interoperable and performant data access. To facilitate the management, development and operation of the HPD platform, NCI coordinates technical and domain committees made up of user representatives, data stewards and informatics experts to provide a forum to discuss, learn and advise NCI's management. This experience has been a useful collaboration and suggests that in the age of interdisciplinary HPD research, Data Stewardship is evolving from a focus on the needs of a single community to one which helps balance priorities and navigates change for multiple communities.
77 FR 58707 - Minimum Internal Control Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-21
... Gaming Commission 25 CFR Part 543 Minimum Internal Control Standards; Final Rule #0;#0;Federal Register... Control Standards AGENCY: National Indian Gaming Commission, Interior. ACTION: Final rule. SUMMARY: The National Indian Gaming Commission (NIGC) amends its minimum internal control standards for Class II gaming...
77 FR 43196 - Minimum Internal Control Standards and Technical Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-24
... NATIONAL INDIAN GAMING COMMISSION 25 CFR Parts 543 and 547 Minimum Internal Control Standards [email protected] . SUPPLEMENTARY INFORMATION: Part 543 addresses minimum internal control standards (MICS) for Class II gaming operations. The regulations require tribes to establish controls and implement...
Davis, Jenny; Morgans, Amee; Burgess, Stephen
2016-04-01
Efficient information systems support the provision of multi-disciplinary aged care and a variety of organisational purposes, including quality, funding, communication and continuity of care. Agreed minimum data sets enable accurate communication across multiple care settings. However, in aged care multiple and poorly integrated data collection frameworks are commonly used for client assessment, government reporting and funding purposes. To determine key information needs in aged care settings to improve information quality, information transfer, safety, quality and continuity of care to meet the complex needs of aged care clients. Modified Delphi methods involving five stages were employed by one aged care provider in Victoria, Australia, to establish stakeholder consensus for a derived minimum data set and address barriers to data quality. Eleven different aged care programs were identified; with five related data dictionaries, three minimum data sets, five program standards or quality frameworks. The remaining data collection frameworks related to diseases classification, funding, service activity reporting, and statistical standards and classifications. A total of 170 different data items collected across seven internal information systems were consolidated to a derived set of 60 core data items and aligned with nationally consistent data collection frameworks. Barriers to data quality related to inconsistencies in data items, staff knowledge, workflow, system access and configuration. The development an internal aged care minimum data set highlighted the critical role of primary data quality in the upstream and downstream use of client information; and presents a platform to build national consistency across the sector.
Islam, Nazrul; Woo, Sun-Hee; Tsujimoto, Hisashi; Kawasaki, Hiroshi; Hirano, Hisashi
2002-09-01
Changes in protein composition of wheat endosperm proteome were investigated in 39 ditelocentric chromosome lines of common wheat (Triticum aestivum L.) cv. Chinese Spring. Two-dimensional gel electrophoresis followed by Coomassie Brilliant Blue staining has resolved a total of 105 protein spots in a gel. Quantitative image analysis of protein spots was performed by PDQuest. Variations in protein spots between the euploid and the 39 ditelocentric lines were evaluated by spot number, appearance, disappearance and intensity. A specific spot present in all gels was taken as an internal standard, and the intensity of all other spots was calculated as the ratio of the internal standard. Out of the 1755 major spots detected in 39 ditelocentric lines, 1372 (78%) spots were found variable in different spot parameters: 147 (11%) disappeared, 978 (71%) up-regulated and 247 (18%) down-regulated. Correlation studies in changes in protein intensities among 24 protein spots across the ditelocentric lines were performed. High correlations in changes of protein intensities were observed among the proteins encoded by genes located in the homoeologous arms. Locations of structural genes controlling 26 spots were identified in 10 chromosomal arms. Multiple regulators of the same protein located at various chromosomal arms were also noticed. Identification of structural genes for most of the proteins was found difficult due to multiple regulators encoding the same protein. Two novel subunits (1B(Z,) 1BDz), the structure of which are very similar to the high molecular weight glutenin subunit 12, were identified, and the chromosome arm locations of these subunits were assigned.
Magnano, Immacolata; Pes, Giovanni Mario; Pilurzi, Giovanna; Cabboi, Maria Paola; Ginatempo, Francesca; Giaconi, Elena; Tolu, Eusebio; Achene, Antonio; Salis, Antonio; Rothwell, John C; Conti, Maurizio; Deriu, Franca
2014-11-01
To investigate vestibulo-masseteric (VMR), acoustic-masseteric (AMR), vestibulo-collic (VCR) and trigemino-collic (TCR) reflexes in patients with multiple sclerosis (MS); to relate abnormalities of brainstem reflexes (BSRs) to multimodal evoked potentials (EPs), clinical and Magnetic Resonance Imaging (MRI) findings. Click-evoked VMR, AMR and VCR were recorded from active masseter and sternocleidomastoid muscles, respectively; TCR was recorded from active sternocleidomastoid muscles, following electrical stimulation of the infraorbital nerve. EPs and MRI were performed with standard techniques. Frequencies of abnormal BSRs were: VMR 62.1%, AMR 55.1%, VCR 25.9%, TCR 58.6%. Brainstem dysfunction was identified by these tests, combined into a four-reflex battery, in 86.9% of cases, by EPs in 82.7%, MRI in 71.7% and clinical examination in 37.7% of cases. The sensitivity of paired BSRs/EPs (93.3%) was significantly higher than combined MRI/clinical testing (70%) in patients with disease duration ⩽6.4years. BSR alterations significantly correlated with clinical, EP and MRI findings. The four-BSR battery effectively increases the performance of standard EPs in early detection of brainstem impairment, otherwise undetected by clinical examination and neuroimaging. Multiple BSR assessment usefully supplements conventional testing and monitoring of brainstem function in MS, especially in newly diagnosed patients. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Multiple imputation to account for measurement error in marginal structural models
Edwards, Jessie K.; Cole, Stephen R.; Westreich, Daniel; Crane, Heidi; Eron, Joseph J.; Mathews, W. Christopher; Moore, Richard; Boswell, Stephen L.; Lesko, Catherine R.; Mugavero, Michael J.
2015-01-01
Background Marginal structural models are an important tool for observational studies. These models typically assume that variables are measured without error. We describe a method to account for differential and non-differential measurement error in a marginal structural model. Methods We illustrate the method estimating the joint effects of antiretroviral therapy initiation and current smoking on all-cause mortality in a United States cohort of 12,290 patients with HIV followed for up to 5 years between 1998 and 2011. Smoking status was likely measured with error, but a subset of 3686 patients who reported smoking status on separate questionnaires composed an internal validation subgroup. We compared a standard joint marginal structural model fit using inverse probability weights to a model that also accounted for misclassification of smoking status using multiple imputation. Results In the standard analysis, current smoking was not associated with increased risk of mortality. After accounting for misclassification, current smoking without therapy was associated with increased mortality [hazard ratio (HR): 1.2 (95% CI: 0.6, 2.3)]. The HR for current smoking and therapy (0.4 (95% CI: 0.2, 0.7)) was similar to the HR for no smoking and therapy (0.4; 95% CI: 0.2, 0.6). Conclusions Multiple imputation can be used to account for measurement error in concert with methods for causal inference to strengthen results from observational studies. PMID:26214338
The Second International Standard for Penicillin*
Humphrey, J. H.; Mussett, M. V.; Perry, W. L. M.
1953-01-01
In 1950 the Department of Biological Standards, National Institute for Medical Research, London, was authorized by the WHO Expert Committee on Biological Standardization to prepare the Second International Standard for Penicillin. A single batch of specially recrystallized sodium penicillin G was obtained and 11 laboratories in seven different countries were requested to take part in its collaborative assay. 112 assays were carried out, of which 101 were done by cup-plate methods using either Staphylococcus aureus or Bacillus subtilis. The results were subjected to standard methods of analysis, on the basis of which the authors define the Second International Standard for Penicillin as containing 1,670 International Units (IU) per mg, with limits of error (P = 0.05) of 1,666-1,674 IU/mg. The International Unit is therefore redefined as the activity contained in 0.0005988 mg of the Second International Standard for Penicillin. PMID:13082387
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-05
... Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines AGENCY... hazardous air pollutants for stationary reciprocating internal combustion engines and the standards of performance for stationary internal combustion engines. Subsequently, the EPA received three petitions for...
The International Standard for Anti-Brucella abortus Serum
Stableforth, A. W.
1954-01-01
In field trials on the eradication of brucellosis from dairy herds in Great Britain, which began in 1933, a serum standard of reference was used for the examination of agglutinating suspensions prepared in different laboratories. In 1937, the Office International des Epizooties (OIE) adopted this standard and made recommendations for its use internationally. These recommendations were revised by OIE in 1948, by the Third Inter-American Congress on Brucellosis and by the Joint FAO/WHO Expert Panel on Brucellosis in 1950, and again by the latter body in 1952. A new batch equivalent in potency to the original standard was established by the WHO Expert Committee on Biological Standardization in 1952 as the International Standard for Anti-Brucella abortus Serum. The International Standard, or a national standard of equivalent potency, ensures comparability of the titres obtained in different countries by different methods, and the results of such comparisons can be expressed in a simple manner by describing the titres in terms of International Units of Brucella antibody. PMID:13199656
Recent technological developments on LGAD and iLGAD detectors for tracking and timing applications
NASA Astrophysics Data System (ADS)
Pellegrini, G.; Baselga, M.; Carulla, M.; Fadeyev, V.; Fernández-Martínez, P.; García, M. Fernández; Flores, D.; Galloway, Z.; Gallrapp, C.; Hidalgo, S.; Liang, Z.; Merlos, A.; Moll, M.; Quirion, D.; Sadrozinski, H.; Stricker, M.; Vila, I.
2016-09-01
This paper reports the latest technological development on the Low Gain Avalanche Detector (LGAD) and introduces a new architecture of these detectors called inverse-LGAD (iLGAD). Both approaches are based on the standard Avalanche Photo Diodes (APD) concept, commonly used in optical and X-ray detection applications, including an internal multiplication of the charge generated by radiation. The multiplication is inherent to the basic n++-p+-p structure, where the doping profile of the p+ layer is optimized to achieve high field and high impact ionization at the junction. The LGAD structures are optimized for applications such as tracking or timing detectors for high energy physics experiments or medical applications where time resolution lower than 30 ps is required. Detailed TCAD device simulations together with the electrical and charge collection measurements are presented through this work.
25 CFR 543.17 - What are the minimum internal control standards for drop and count?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for drop and count? 543.17 Section 543.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.17 What are the minimum internal control standards for drop and count?...
25 CFR 543.15 - What are the minimum internal control standards for lines of credit?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for lines of credit? 543.15 Section 543.15 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.15 What are the minimum internal control standards for lines of credi...
25 CFR 543.9 - What are the minimum internal control standards for pull tabs?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for pull tabs? 543.9 Section 543.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.9 What are the minimum internal control standards for pull tabs? (a)...
25 CFR 543.13 - What are the minimum internal control standards for complimentary services or items?
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for complimentary services or items? 543.13 Section 543.13 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.13 What are the minimum internal control standards fo...
25 CFR 543.9 - What are the minimum internal control standards for pull tabs?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for pull tabs? 543.9 Section 543.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.9 What are the minimum internal control standards for pull tabs? (a)...
25 CFR 543.15 - What are the minimum internal control standards for lines of credit?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for lines of credit? 543.15 Section 543.15 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.15 What are the minimum internal control standards for lines of credi...
25 CFR 543.17 - What are the minimum internal control standards for drop and count?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for drop and count? 543.17 Section 543.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.17 What are the minimum internal control standards for drop and count?...
25 CFR 543.13 - What are the minimum internal control standards for complimentary services or items?
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for complimentary services or items? 543.13 Section 543.13 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.13 What are the minimum internal control standards fo...
Huang, Yande; Su, Bao-Ning; Ye, Qingmei; Palaniswamy, Venkatapuram A; Bolgar, Mark S; Raglione, Thomas V
2014-01-01
The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained. Copyright © 2013 Elsevier B.V. All rights reserved.
"They Will Come to Understand": Supervisor Reflections on International Medical Electives.
Roebbelen, Erica; Dorman, Katie; Hunter, Andrea; Kraeker, Christian; O'Shea, Tim; Bozinoff, Nikki
2018-03-22
Phenomenon: Increasing numbers of medical students from high-income countries are undertaking international medical electives (IMEs) during their training. Much has been written about the benefits of these experiences for the student, and concerns have been raised regarding the burden of IMEs on host communities. The voices of physicians from low- and middle-income countries who supervise IMEs have not been explored in depth. The current study sought to investigate host-physician perspectives on IMEs. Host supervisors were recruited by convenience sampling through students travelling abroad for IMEs during the summer of 2012. From 2012 through 2014, 11 semistructured interviews were conducted by telephone with host supervisors from Nepal, Uganda, Ghana, Guyana, and Kenya. Participants were invited to describe their motivations for hosting IMEs and their experiences of the benefits and harms of IMEs. Interviews were transcribed verbatim and checked for accuracy. An initial coding framework was developed and underwent multiple revisions, after which analytic categories were derived using conventional qualitative content analysis. For host supervisors, visits from international medical students provided a window into the resource-rich medical practice of high-income countries, and supervisors positioned themselves, their education, and clinical expertise against perceived standards of the international students' context. Hosting IMEs also contributed to supervisors' identities as educators connected to a global community. Supervisors described the challenge of helping students navigate their distress when confronting global health inequity. Finally, the desire for increasingly reciprocal relationships was expressed as a hope for the future. Insights: IMEs can be formative for host supervisors' identities and are used to benchmark host institutions compared with international medical standards. Reciprocity was articulated as essential for IMEs moving forward.
Tang, Hsin-Yao; Beer, Lynn A.; Barnhart, Kurt T.; Speicher, David W.
2011-01-01
Stable isotope dilution-multiple reaction monitoring-mass spectrometry (SID-MRM-MS) has emerged as a promising platform for verification of serological candidate biomarkers. However, cost and time needed to synthesize and evaluate stable isotope peptides, optimize spike-in assays, and generate standard curves, quickly becomes unattractive when testing many candidate biomarkers. In this study, we demonstrate that label-free multiplexed MRM-MS coupled with major protein depletion and 1-D gel separation is a time-efficient, cost-effective initial biomarker verification strategy requiring less than 100 μl serum. Furthermore, SDS gel fractionation can resolve different molecular weight forms of targeted proteins with potential diagnostic value. Because fractionation is at the protein level, consistency of peptide quantitation profiles across fractions permits rapid detection of quantitation problems for specific peptides from a given protein. Despite the lack of internal standards, the entire workflow can be highly reproducible, and long-term reproducibility of relative protein abundance can be obtained using different mass spectrometers and LC methods with external reference standards. Quantitation down to ~200 pg/mL could be achieved using this workflow. Hence, the label-free GeLC-MRM workflow enables rapid, sensitive, and economical initial screening of large numbers of candidate biomarkers prior to setting up SID-MRM assays or immunoassays for the most promising candidate biomarkers. PMID:21726088
Tang, Hsin-Yao; Beer, Lynn A; Barnhart, Kurt T; Speicher, David W
2011-09-02
Stable isotope dilution-multiple reaction monitoring-mass spectrometry (SID-MRM-MS) has emerged as a promising platform for verification of serological candidate biomarkers. However, cost and time needed to synthesize and evaluate stable isotope peptides, optimize spike-in assays, and generate standard curves quickly becomes unattractive when testing many candidate biomarkers. In this study, we demonstrate that label-free multiplexed MRM-MS coupled with major protein depletion and 1D gel separation is a time-efficient, cost-effective initial biomarker verification strategy requiring less than 100 μL of serum. Furthermore, SDS gel fractionation can resolve different molecular weight forms of targeted proteins with potential diagnostic value. Because fractionation is at the protein level, consistency of peptide quantitation profiles across fractions permits rapid detection of quantitation problems for specific peptides from a given protein. Despite the lack of internal standards, the entire workflow can be highly reproducible, and long-term reproducibility of relative protein abundance can be obtained using different mass spectrometers and LC methods with external reference standards. Quantitation down to ~200 pg/mL could be achieved using this workflow. Hence, the label-free GeLC-MRM workflow enables rapid, sensitive, and economical initial screening of large numbers of candidate biomarkers prior to setting up SID-MRM assays or immunoassays for the most promising candidate biomarkers.
Ellis, D W; Srigley, J
2016-01-01
Key quality parameters in diagnostic pathology include timeliness, accuracy, completeness, conformance with current agreed standards, consistency and clarity in communication. In this review, we argue that with worldwide developments in eHealth and big data, generally, there are two further, often overlooked, parameters if our reports are to be fit for purpose. Firstly, population-level studies have clearly demonstrated the value of providing timely structured reporting data in standardised electronic format as part of system-wide quality improvement programmes. Moreover, when combined with multiple health data sources through eHealth and data linkage, structured pathology reports become central to population-level quality monitoring, benchmarking, interventions and benefit analyses in public health management. Secondly, population-level studies, particularly for benchmarking, require a single agreed international and evidence-based standard to ensure interoperability and comparability. This has been taken for granted in tumour classification and staging for many years, yet international standardisation of cancer datasets is only now underway through the International Collaboration on Cancer Reporting (ICCR). In this review, we present evidence supporting the role of structured pathology reporting in quality improvement for both clinical care and population-level health management. Although this review of available evidence largely relates to structured reporting of cancer, it is clear that the same principles can be applied throughout anatomical pathology generally, as they are elsewhere in the health system.
Comparisons of Two Plasma Instruments on the International Space Station
NASA Astrophysics Data System (ADS)
Balthazor, R.; McHarg, M. G.; Minow, J. I.; Chandler, M. O.; Musick, J. D.; Feldmesser, H.; Darrin, M. A.; Osiander, R.
2011-12-01
The United States Air Force Academy's Canary instrument, a low-cost ion spectrometer with integrated charge multiplication, was installed on the International Space Station (ISS) on shuttle flight STS-134. The primary goal of the Canary experiment is to measure ion signals in the wake when ISS is flying in the standard +XVV attitude. However, the instrument is pointed (approximately) into ram and detects ambient Low Earth Orbit ions when the ISS is flying in the -XVV attitude. Simultaneous observations with NASA's Floating Plasma Measurement Unit (FPMU) have been taken during these times, and the results from each instrument are compared, in order to determine the origin of energy variations observed in the Canary ion signal. In addition, insights into the ISS floating plasma potential at the two different instrument locations can be obtained.
Absolute Spectrophotometric Calibration to 1% from the FUV through the near-IR
NASA Astrophysics Data System (ADS)
Finley, David
2005-07-01
We propose a significant improvement to the existing HST calibration. The current calibration is based on three primary DA white dwarf standards, GD 71, GD 153, and G 191-B2B. The standard fluxes are calculated using NLTE models, with effective temperatures and gravities that were derived from Balmer line fits using LTE models. We propose to improve the accuracy and internal consistency of the calibration by deriving corrected effective temperatures and gravities based on fitting the observed line profiles with updated NLTE models, and including the fit results from multiple STIS spectra, rather than the {usually} 1 or 2 ground-based spectra used previously. We will also determine the fluxes for 5 new, fainter primary or secondary standards, extending the standard V magnitude lower limit from 13.4 to 16.5, and extending the wavelength coverage from 0.1 to 2.5 micron. The goal is to achieve an overall flux accuracy of 1%, which will be needed, for example, for the upcoming supernova survey missions to measure the equation of state of the dark energy that is accelerating the expansion of the universe.
Donaldson, Keri J; Shaw, Leslie M
2010-01-01
We describe a multiple reaction monitoring positive ion HPLC/tandem mass spectrometric method for quantification of tacrolimus in human whole blood with online extraction and cleanup. Included in this procedure: API 2000 triple quadrupole mass spectrometer with turbo-ion spray source (Applied Biosystems, Foster City, CA); 10-port diverter/switching valve (Valco, Houston, TX); HPLC system (Agilent Technologies series 1100, Wilmington, DE); 10 mm (C(18)) guard cartridge (Perkin Elmer, Norwalk, CT) used as an extraction column; a Nova-Pak C18 analytical column (2.1 x 150 mm I.D., 4 microm, Waters Corp, Milford, MA); washing solution, methanol: 30 mM ammonium acetate pH 5.1 (80:20); eluting solution, methanol:30 mM ammonium acetate pH 5.1 (97:3); flow rate 0.8 mL/min; and a run-time of 2.8 min. The first and third quadrupoles were set to detect the ammonium adduct ion and a high mass fragment of tacrolimus (m/z 821.5-->768.3), and of an internal standard (ascomycin) (m/z 901.8-->834.4). The lower limit of quantification of this method is 3.75 mg/L. The concentration of drug is determined by comparing peak-area ratios for tacrolimus and internal standard to a standard curve constructed using non-weighted linear through zero regression.
Lee, Wanhyung; Yeom, Hyungseon; Yoon, Jin-Ha; Won, Jong-Uk; Jung, Pil Kyun; Lee, June-Hee; Seok, Hongdeok; Roh, Jaehoon
2016-08-01
Occupation influences the risk for developing chronic metabolic diseases. We compared the prevalence of MetS by International Standard Classification of Occupations using the nationally representative data in Korea (KNHANES). We enrolled 16,763 workers (9,175 males; 7,588 females) who had measurements for the National Cholesterol Education Program criteria III and other variables. OR and 95%CIs for MetS and its components were estimated according to occupation using the multiple logistic regression models. The occupational groups with the highest age-standardized prevalence of MetS were lower skilled white-collar men (31.1 ± 2.4%) and green-collar women (24.2 ± 2.9%). Compared with the unskilled male blue-collar group, which had the lowest prevalence of MetS, the OR (95%CIs) of MetS in men were 1.77 (1.45-2.15) in higher skilled white-collar, 1.82 (1.47-2.26) in lower-skilled white-collar, 1.63 (1.32-2.01) in pink-collar and 1.37 (1.13-1.66) in skilled blue-collar workers in final logistic regression model. MetS and its components vary by occupational category and gender in ways that may guide health interventions. Am. J. Ind. Med. 59:685-694, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Exploration of sequence space as the basis of viral RNA genome segmentation.
Moreno, Elena; Ojosnegros, Samuel; García-Arriaza, Juan; Escarmís, Cristina; Domingo, Esteban; Perales, Celia
2014-05-06
The mechanisms of viral RNA genome segmentation are unknown. On extensive passage of foot-and-mouth disease virus in baby hamster kidney-21 cells, the virus accumulated multiple point mutations and underwent a transition akin to genome segmentation. The standard single RNA genome molecule was replaced by genomes harboring internal in-frame deletions affecting the L- or capsid-coding region. These genomes were infectious and killed cells by complementation. Here we show that the point mutations in the nonstructural protein-coding region (P2, P3) that accumulated in the standard genome before segmentation increased the relative fitness of the segmented version relative to the standard genome. Fitness increase was documented by intracellular expression of virus-coded proteins and infectious progeny production by RNAs with the internal deletions placed in the sequence context of the parental and evolved genome. The complementation activity involved several viral proteins, one of them being the leader proteinase L. Thus, a history of genetic drift with accumulation of point mutations was needed to allow a major variation in the structure of a viral genome. Thus, exploration of sequence space by a viral genome (in this case an unsegmented RNA) can reach a point of the space in which a totally different genome structure (in this case, a segmented RNA) is favored over the form that performed the exploration.
NASA Astrophysics Data System (ADS)
McCoy, Kevin; Mays, Claude
2008-04-01
The fuel rod performance and neutronics of enhanced thermal conductivity oxide (ECO) nuclear fuel with BeO have been compared to those of standard UO 2 fuel. The standards of comparison were that the ECO fuel should have the same infinite neutron-multiplication factor kinf at end of life and provide the same energy extraction per fuel assembly over its lifetime. The BeO displaces some uranium, so equivalence with standard UO 2 fuel was obtained by increasing the burnup and slightly increasing the enrichment. The COPERNIC fuel rod performance code was adapted to account for the effect of BeO on thermal properties. The materials considered were standard UO 2, UO 2 with 4.0 vol.% BeO, and UO 2 with 9.6 vol.% BeO. The smaller amount of BeO was assumed to provide increases in thermal conductivity of 0, 5, or 10%, whereas the larger amount was assumed to provide an increase of 50%. A significant improvement in performance was seen, as evidenced by reduced temperatures, internal rod pressures, and fission gas release, even with modest (5-10%) increases in thermal conductivity. The benefits increased monotonically with increasing thermal conductivity. Improvements in LOCA initialization performance were also seen. A neutronic calculation considered a transition from standard UO 2 fuel to ECO fuel. The calculation indicated that only a small increase in enrichment is required to maintain the kinf at end of life. The smallness of the change was attributed to the neutron-multiplication reaction of Be with fast neutrons and the moderating effect of BeO. Adoption of ECO fuel was predicted to provide a net reduction in uranium cost. Requirements for industrial hygiene were found to be comparable to those for processing of UO 2.
National policy on physical activity: the development of a policy audit tool.
Bull, Fiona C; Milton, Karen; Kahlmeier, Sonja
2014-02-01
Physical inactivity is a leading risk factor for noncommunicable disease worldwide. Increasing physical activity requires large scale actions and relevant, supportive national policy across multiple sectors. The policy audit tool (PAT) was developed to provide a standardized instrument to assess national policy approaches to physical activity. A draft tool, based on earlier work, was developed and pilot-tested in 7 countries. After several rounds of revisions, the final PAT comprises 27 items and collects information on 1) government structure, 2) development and content of identified key policies across multiple sectors, 3) the experience of policy implementation at both the national and local level, and 4) a summary of the PAT completion process. PAT provides a standardized instrument for assessing progress of national policy on physical activity. Engaging a diverse international group of countries in the development helped ensure PAT has applicability across a wide range of countries and contexts. Experiences from the development of the PAT suggests that undertaking an audit of health enhancing physical activity (HEPA) policy can stimulate greater awareness of current policy opportunities and gaps, promote critical debate across sectors, and provide a catalyst for collaboration on policy level actions. The final tool is available online.
Sun, Bing; Zheng, Yun-Ling
2018-01-01
Currently there is no sensitive, precise, and reproducible method to quantitate alternative splicing of mRNA transcripts. Droplet digital™ PCR (ddPCR™) analysis allows for accurate digital counting for quantification of gene expression. Human telomerase reverse transcriptase (hTERT) is one of the essential components required for telomerase activity and for the maintenance of telomeres. Several alternatively spliced forms of hTERT mRNA in human primary and tumor cells have been reported in the literature. Using one pair of primers and two probes for hTERT, four alternatively spliced forms of hTERT (α-/β+, α+/β- single deletions, α-/β- double deletion, and nondeletion α+/β+) were accurately quantified through a novel analysis method via data collected from a single ddPCR reaction. In this chapter, we describe this ddPCR method that enables direct quantitative comparison of four alternatively spliced forms of the hTERT messenger RNA without the need for internal standards or multiple pairs of primers specific for each variant, eliminating the technical variation due to differential PCR amplification efficiency for different amplicons and the challenges of quantification using standard curves. This simple and straightforward method should have general utility for quantifying alternatively spliced gene transcripts.
Common Calibration Source for Monitoring Long-term Ozone Trends
NASA Technical Reports Server (NTRS)
Kowalewski, Matthew
2004-01-01
Accurate long-term satellite measurements are crucial for monitoring the recovery of the ozone layer. The slow pace of the recovery and limited lifetimes of satellite monitoring instruments demands that datasets from multiple observation systems be combined to provide the long-term accuracy needed. A fundamental component of accurately monitoring long-term trends is the calibration of these various instruments. NASA s Radiometric Calibration and Development Facility at the Goddard Space Flight Center has provided resources to minimize calibration biases between multiple instruments through the use of a common calibration source and standardized procedures traceable to national standards. The Facility s 50 cm barium sulfate integrating sphere has been used as a common calibration source for both US and international satellite instruments, including the Total Ozone Mapping Spectrometer (TOMS), Solar Backscatter Ultraviolet 2 (SBUV/2) instruments, Shuttle SBUV (SSBUV), Ozone Mapping Instrument (OMI), Global Ozone Monitoring Experiment (GOME) (ESA), Scanning Imaging SpectroMeter for Atmospheric ChartographY (SCIAMACHY) (ESA), and others. We will discuss the advantages of using a common calibration source and its effects on long-term ozone data sets. In addition, sphere calibration results from various instruments will be presented to demonstrate the accuracy of the long-term characterization of the source itself.
Rapid prototyping and evaluation of programmable SIMD SDR processors in LISA
NASA Astrophysics Data System (ADS)
Chen, Ting; Liu, Hengzhu; Zhang, Botao; Liu, Dongpei
2013-03-01
With the development of international wireless communication standards, there is an increase in computational requirement for baseband signal processors. Time-to-market pressure makes it impossible to completely redesign new processors for the evolving standards. Due to its high flexibility and low power, software defined radio (SDR) digital signal processors have been proposed as promising technology to replace traditional ASIC and FPGA fashions. In addition, there are large numbers of parallel data processed in computation-intensive functions, which fosters the development of single instruction multiple data (SIMD) architecture in SDR platform. So a new way must be found to prototype the SDR processors efficiently. In this paper we present a bit-and-cycle accurate model of programmable SIMD SDR processors in a machine description language LISA. LISA is a language for instruction set architecture which can gain rapid model at architectural level. In order to evaluate the availability of our proposed processor, three common baseband functions, FFT, FIR digital filter and matrix multiplication have been mapped on the SDR platform. Analytical results showed that the SDR processor achieved the maximum of 47.1% performance boost relative to the opponent processor.
Kumar, Shaji; Durie, Brian; Nahi, Hareth; Vij, Ravi; Dimopoulos, Meletios A; Kastritis, Efstathios; Terpos, Evangelos; Leleu, Xavier; Beksac, Meral; Goldschmidt, Hartmut; Hillengass, Jens; Su, Zhuo; Hutton, Brian; Cameron, Chris; Khan, Imran; Lam, Annette
2018-05-09
Daratumumab is a CD38-directed monoclonal antibody approved for treating multiple myeloma (MM). Propensity score matching (PSM) based on individual patient data (IPD) was conducted to compare overall survival (OS) and progression-free survival (PFS) for daratumumab versus real-world standard of care (SOC). IPD for patients with relapsed and refractory (RR) MM treated with daratumumab monotherapy were from the GEN501 and SIRIUS studies; IPD for patients treated with SOC were from an International Myeloma Working Group (IMWG) chart review of patients with RRMM. Prior to PSM, patients treated with daratumumab had significantly longer OS (median 20.1 vs. 10.1 months, hazard ratio [HR] = 0.51 [0.39-0.67]) and PFS (median 4.0 vs. 2.8 months, HR = 0.73 [0.58-0.92]) than patients treated with SOC therapies. After PSM, daratumumab maintained a significantly prolonged OS (19.9 vs. 9.2 months, HR = 0.44 [0.31-0.63]) and PFS (3.9 vs. 1.6 months, HR = 0.56 [0.42-0.74]) compared with SOC.
This standard operating procedure describes the method used for preparing internal standard, surrogate recovery standard and calibration standard solutions for neutral analytes used for gas chromatography/mass spectrometry analysis.
Performance management of multiple access communication networks
NASA Astrophysics Data System (ADS)
Lee, Suk; Ray, Asok
1993-12-01
This paper focuses on conceptual design, development, and implementation of a performance management tool for computer communication networks to serve large-scale integrated systems. The objective is to improve the network performance in handling various types of messages by on-line adjustment of protocol parameters. The techniques of perturbation analysis of Discrete Event Dynamic Systems (DEDS), stochastic approximation (SA), and learning automata have been used in formulating the algorithm of performance management. The efficacy of the performance management tool has been demonstrated on a network testbed. The conceptual design presented in this paper offers a step forward to bridging the gap between management standards and users' demands for efficient network operations since most standards such as ISO (International Standards Organization) and IEEE address only the architecture, services, and interfaces for network management. The proposed concept of performance management can also be used as a general framework to assist design, operation, and management of various DEDS such as computer integrated manufacturing and battlefield C(sup 3) (Command, Control, and Communications).
NASA Astrophysics Data System (ADS)
Maling, George C., Jr.
Recent advances in noise analysis and control theory and technology are discussed in reviews and reports. Topics addressed include noise generation; sound-wave propagation; noise control by external treatments; vibration and shock generation, transmission, isolation, and reduction; multiple sources and paths of environmental noise; noise perception and the physiological and psychological effects of noise; instrumentation, signal processing, and analysis techniques; and noise standards and legal aspects. Diagrams, drawings, graphs, photographs, and tables of numerical data are provided.
MSSM-inspired multifield inflation
NASA Astrophysics Data System (ADS)
Dubinin, M. N.; Petrova, E. Yu.; Pozdeeva, E. O.; Sumin, M. V.; Vernov, S. Yu.
2017-12-01
Despite the fact that experimentally with a high degree of statistical significance only a single Standard Model-like Higgs boson is discovered at the LHC, extended Higgs sectors with multiple scalar fields not excluded by combined fits of the data are more preferable theoretically for internally consistent realistic models of particle physics. We analyze the inflationary scenarios which could be induced by the two-Higgs-doublet potential of the Minimal Supersymmetric Standard Model (MSSM) where five scalar fields have non-minimal couplings to gravity. Observables following from such MSSM-inspired multifield inflation are calculated and a number of consistent inflationary scenarios are constructed. Cosmological evolution with different initial conditions for the multifield system leads to consequences fully compatible with observational data on the spectral index and the tensor-to-scalar ratio. It is demonstrated that the strong coupling approximation is precise enough to describe such inflationary scenarios.
International Standardization of Bed Rest Standard Measures
NASA Technical Reports Server (NTRS)
Cromwell, Ronita L.
2010-01-01
This slide presentation gives an overview of the standardization of bed rest measures. The International Countermeasures Working Group attempted to define and agree internationally on standard measurements for spaceflight based bed rest studies. The group identified the experts amongst several stakeholder agencys. It included information on exercise, muscle, neurological, psychological, bone and cardiovascular measures.
First Results from the iSTAR International STudy on Astronomy Reasoning
NASA Astrophysics Data System (ADS)
Tatge, Coty B.; Slater, Stephanie J.; Slater, Timothy F.
2015-01-01
Our best efforts in the United States to dramatically improve teaching and learning in astronomy courses has been less than satisfactory despite Herculean efforts. A possible solution is to expand our view beyond our own culture's borders and presumptions in order to bring our shortcomings in discipline-based astronomy education research to light. Before we can begin the process of international comparisons of student conceptual understanding, we need to better understand how different citizens of different countries position astronomy culturally. Under the banner of the International STudy on Astronomy Reasoning Project, iSTAR, we are now carefully observing how foreign experts in teaching astronomy and the science of astronomy translate the Test Of Astronomy STandards - TOAST multiple-choice assessment instrument to look for subtle clues revealed during the translation process. The TOAST is the widely used standard to evaluate students' gains in the United States' Astronomy classrooms. We hope that the process of translation itself will help us comprehend how other cultures think differently about astronomical concepts and eventually we are looking to obtain useful data of how other cultures develop their society's understanding of particular astronomy aspects where we may fall short. Several of the iSTAR Project's bilingual speakers are documenting their thoughts and insights as they translate the TOAST. The end-goal is to collect a comprehensible, well-defined, and logical translation in various languages that are culturally sensitive and linguistically accurate. This project is sponsored and managed by the CAPER Center for Astronomy & Physics Education Research at CAPERTeam.com in collaboration with members of the International Astronomical Union-Commission 46.
Slattery, Marcia J.; Grieve, Adam J.; Ames, Michelle E.; Armstrong, Jeffrey M.; Essex, Marilyn J.
2014-01-01
Stress and associated alterations in hypothalamic-pituitary-adrenal (HPA) function have deleterious impacts on the development of multiple mental and physical health problems. Prior research has aimed to identify individuals most at risk for the development of these stress-related maladies by examining factors that may contribute to inter-individual differences in HPA responses to acute stress. The objectives of this study were to investigate, in adolescents, 1) whether differences in neurocognitive abilities influenced cortisol reactivity to an acute stressor, 2) whether internalizing psychiatric disorders influenced this relationship, and 3) whether acute cognitive stress-appraisal mechanisms mediated an association between neurocognitive function and cortisol reactivity. Subjects were 70 adolescents from a community sample who underwent standardized neurocognitive assessments of IQ, achievement, and declarative memory measures at mean age 14 and whose physiological and behavioral responses to a standardized psychosocial stress paradigm (Trier Social Stress Test, TSST) were assessed at mean age 18. Results showed that, among all adolescents, lower nonverbal memory performance predicted lower cortisol reactivity. In addition, internalizing disorders interacted with verbal memory such that the association with cortisol reactivity was strongest for adolescents with internalizing disorders. Finally, lower secondary cognitive appraisal of coping in anticipation of the TSST independently predicted lower cortisol reactivity but did not mediate the neurocognitive–cortisol relationship. Findings suggest that declarative memory may contribute to inter-individual differences in acute cortisol reactivity in adolescents, internalizing disorders may influence this relationship, and cognitive stress appraisal also predicts cortisol reactivity. Developmental, research, and clinical implications are discussed. PMID:23253895
Kramer, Robin S S; Manesi, Zoi; Towler, Alice; Reynolds, Michael G; Burton, A Mike
2018-01-01
As faces become familiar, we come to rely more on their internal features for recognition and matching tasks. Here, we assess whether this same pattern is also observed for a card sorting task. Participants sorted photos showing either the full face, only the internal features, or only the external features into multiple piles, one pile per identity. In Experiments 1 and 2, we showed the standard advantage for familiar faces-sorting was more accurate and showed very few errors in comparison with unfamiliar faces. However, for both familiar and unfamiliar faces, sorting was less accurate for external features and equivalent for internal and full faces. In Experiment 3, we asked whether external features can ever be used to make an accurate sort. Using familiar faces and instructions on the number of identities present, we nevertheless found worse performance for the external in comparison with the internal features, suggesting that less identity information was available in the former. Taken together, we show that full faces and internal features are similarly informative with regard to identity. In comparison, external features contain less identity information and produce worse card sorting performance. This research extends current thinking on the shift in focus, both in attention and importance, toward the internal features and away from the external features as familiarity with a face increases.
Limits of linearity and detection for some drugs of abuse.
Needleman, S B; Romberg, R W
1990-01-01
The limits of linearity (LOL) and detection (LOD) are important factors in establishing the reliability of an analytical procedure for accurately assaying drug concentrations in urine specimens. Multiple analyses of analyte over an extended range of concentrations provide a measure of the ability of the analytical procedure to correctly identify known quantities of drug in a biofluid matrix. Each of the seven drugs of abuse gives linear analytical responses from concentrations at or near their LOD to concentrations several-fold higher than those generally encountered in the drug screening laboratory. The upper LOL exceeds the Department of Navy (DON) cutoff values by factors of approximately 2 to 160. The LOD varies from 0.4 to 5.0% of the DON cutoff value for each drug. The limit of quantitation (LOQ) is calculated as the LOD + 7 SD. The range for LOL is greater for drugs analyzed with deuterated internal standards compared with those using conventional internal standards. For THC acid, cocaine, PCP, and morphine, LOLs are 8 to 160-fold greater than the defined cutoff concentrations. For the other drugs, the LOL's are only 2 to 4-fold greater than the defined cutoff concentrations.
Liu, Shi-jia; Zhou, Ling; Zhang, Jun; Yu, Bo-yang; Li, Chang-yin; Liu, Zi-xiu; Ju, Wen-zheng
2013-04-01
A highly sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for the determination of limonin in beagle dog plasma using nimodipine as internal standard. The analyte and internal standard (IS) were extracted with ether followed by a rapid isocratic elution with 10 mm ammonium acetate buffer-methanol (26:74, v/v) on a C18 column (150 × 2.1 mm i.d.) and subsequent analysis by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 469.4 → 229.3 and m/z 417.2 → 122.0 were used to measure the analyte and the IS. The assay was linear over the concentration range of 0.625-100 ng/mL for limonin in dog plasma. The lower limit of quantification was 0.312 ng/mL and the extraction recovery was >90.4% for limonin. The inter- and intra-day precision of the method at three concentrations was less than 9.9%. The method was successfully applied to pharmacokinetic study of limonin in dogs. Copyright © 2012 John Wiley & Sons, Ltd.
The International Standard for Aureomycin
Humphrey, J. H.; Lightbown, J. W.; Mussett, M. V.; Perry, W. L. M.
1953-01-01
In 1950, the Department of Biological Standards, National Institute for Medical Research, London, was authorized by the WHO Expert Committee on Biological Standardization to proceed with the establishment of an International Standard for Aureomycin. A 100-g batch of aureomycin was obtained and was compared with the Standard Preparation of Aureomycin of the United States Food and Drug Administration (FDA) in a collaborative assay in which six laboratories in five countries participated. In all, 30 assays were carried out; 26 of these were done by biological methods, using Sarcina lutea, Bacillus pumilus, Staphylococcus aureus, or Bacillus cereus, and the remaining four by physicochemical methods. The results were subjected to standard methods of analysis, and the overall weighted mean potency (calculated from the biological assays only) was 1.0139, with limits of error of 99.5% to 100.5%. Since the International Standard is 1.39% more potent than the FDA Standard Preparation, it is probable that the latter contains a small amount of inert material; it is also possible that the International Standard itself is not 100% pure. For most practical purposes, however, both preparations may be regarded as substantially pure, and it is considered that to alter the present practice of quoting aureomycin dosage in metric units of weight would be inadvisable. Nevertheless, since the International Standard may not be a pure substance, a unit notation—for use where required in bioassays—is desirable, and the International Unit of Aureomycin has therefore been defined as the activity contained in one microgram of the International Standard. PMID:13141137
Sleno, Lekha; Volmer, Dietrich A
2006-01-01
Growing interest in the ability to conduct quantitative assays for small molecules by matrix-assisted laser desorption/ionization (MALDI) has been the driving force for several recent studies. This present work includes the investigation of internal standards for these analyses using a high-repetition rate MALDI triple quadrupole instrument. Certain physicochemical properties are assessed for predicting possible matches for internal standards for different small molecules. The importance of similar molecular weight of an internal standard to its analyte is seen through experiments with a series of acylcarnitines, having a fixed charge site and growing alkyl chain length. Both acetyl- and hexanoyl-carnitine were systematically assessed with several other acylcarnitine compounds as internal standards. The results clearly demonstrate that closely matched molecular weights between analyte and internal standard are essential for acceptable quantitation results. Using alpha-cyano-4-hydroxycinnamic acid as the organic matrix, the similarities between analyte and internal standard remain the most important parameter and not necessarily their even distribution within the solid sample spot. Several 4-quinolone antibiotics as well as a diverse group of pharmaceutical drugs were tested as internal standards for the 4-quinolone, ciprofloxacin. Quantitative results were shown using the solution-phase properties, log D and pKa, of these molecules. Their distribution coefficients, log D, are demonstrated as a fundamental parameter for similar crystallization patterns of analyte and internal standard. In the end, it was also possible to quantify ciprofloxacin using a drug from a different compound class, namely quinidine, having a similar log D value as the analyte. Copyright 2006 John Wiley & Sons, Ltd.
The NCAR Research Data Archive's Hybrid Approach for Data Discovery and Access
NASA Astrophysics Data System (ADS)
Schuster, D.; Worley, S. J.
2013-12-01
The NCAR Research Data Archive (RDA http://rda.ucar.edu) maintains a variety of data discovery and access capabilities for it's 600+ dataset collections to support the varying needs of a diverse user community. In-house developed and standards-based community tools offer services to more than 10,000 users annually. By number of users the largest group is external and access the RDA through web based protocols; the internal NCAR HPC users are fewer in number, but typically access more data volume. This paper will detail the data discovery and access services maintained by the RDA to support both user groups, and show metrics that illustrate how the community is using the services. The distributed search capability enabled by standards-based community tools, such as Geoportal and an OAI-PMH access point that serves multiple metadata standards, provide pathways for external users to initially discover RDA holdings. From here, in-house developed web interfaces leverage primary discovery level metadata databases that support keyword and faceted searches. Internal NCAR HPC users, or those familiar with the RDA, may go directly to the dataset collection of interest and refine their search based on rich file collection metadata. Multiple levels of metadata have proven to be invaluable for discovery within terabyte-sized archives composed of many atmospheric or oceanic levels, hundreds of parameters, and often numerous grid and time resolutions. Once users find the data they want, their access needs may vary as well. A THREDDS data server running on targeted dataset collections enables remote file access through OPENDAP and other web based protocols primarily for external users. In-house developed tools give all users the capability to submit data subset extraction and format conversion requests through scalable, HPC based delayed mode batch processing. Users can monitor their RDA-based data processing progress and receive instructions on how to access the data when it is ready. External users are provided with RDA server generated scripts to download the resulting request output. Similarly they can download native dataset collection files or partial files using Wget or cURL based scripts supplied by the RDA server. Internal users can access the resulting request output or native dataset collection files directly from centralized file systems.
A Standardized Relative Resource Cost Model for Medical Care: Application to Cancer Control Programs
2013-01-01
Medicare data represent 75% of aged and permanently disabled Medicare beneficiaries enrolled in the fee-for-service (FFS) indemnity option, but the data omit 25% of beneficiaries enrolled in Medicare Advantage health maintenance organizations (HMOs). Little research has examined how longitudinal patterns of utilization differ between HMOs and FFS. The Burden of Cancer Study developed and implemented an algorithm to assign standardized relative costs to HMO and Medicare FFS data consistently across time and place. Medicare uses 15 payment systems to reimburse FFS providers for covered services. The standardized relative resource cost algorithm (SRRCA) adapts these various payment systems to utilization data. We describe the rationale for modifications to the Medicare payment systems and discuss the implications of these modifications. We applied the SRRCA to data from four HMO sites and the linked Surveillance, Epidemiology, and End Results–Medicare data. Some modifications to Medicare payment systems were required, because data elements needed to categorize utilization were missing from both data sources. For example, data were not available to create episodes for home health services received, so we assigned costs per visit based on visit type (nurse, therapist, and aide). For inpatient utilization, we modified Medicare’s payment algorithm by changing it from a flat payment per diagnosis-related group to daily rates for diagnosis-related groups to differentiate shorter versus longer stays. The SRRCA can be used in multiple managed care plans and across multiple FFS delivery systems within the United States to create consistent relative cost data for economic analyses. Prior to international use of the SRRCA, data need to be standardized. PMID:23962514
Core Outcome Set-STAndards for Development: The COS-STAD recommendations.
Kirkham, Jamie J; Davis, Katherine; Altman, Douglas G; Blazeby, Jane M; Clarke, Mike; Tunis, Sean; Williamson, Paula R
2017-11-01
The use of core outcome sets (COS) ensures that researchers measure and report those outcomes that are most likely to be relevant to users of their research. Several hundred COS projects have been systematically identified to date, but there has been no formal quality assessment of these studies. The Core Outcome Set-STAndards for Development (COS-STAD) project aimed to identify minimum standards for the design of a COS study agreed upon by an international group, while other specific guidance exists for the final reporting of COS development studies (Core Outcome Set-STAndards for Reporting [COS-STAR]). An international group of experienced COS developers, methodologists, journal editors, potential users of COS (clinical trialists, systematic reviewers, and clinical guideline developers), and patient representatives produced the COS-STAD recommendations to help improve the quality of COS development and support the assessment of whether a COS had been developed using a reasonable approach. An open survey of experts generated an initial list of items, which was refined by a 2-round Delphi survey involving nearly 250 participants representing key stakeholder groups. Participants assigned importance ratings for each item using a 1-9 scale. Consensus that an item should be included in the set of minimum standards was defined as at least 70% of the voting participants from each stakeholder group providing a score between 7 and 9. The Delphi survey was followed by a consensus discussion with the study management group representing multiple stakeholder groups. COS-STAD contains 11 minimum standards that are the minimum design recommendations for all COS development projects. The recommendations focus on 3 key domains: the scope, the stakeholders, and the consensus process. The COS-STAD project has established 11 minimum standards to be followed by COS developers when planning their projects and by users when deciding whether a COS has been developed using reasonable methods.
Xu, Fei; Liu, Feng; Wang, Chaozhan; Wei, Yinmao
2018-02-01
In this study, the strategy of unique adsorbent combined with isotope labeled internal standards was used to significantly reduce the matrix effect for the enrichment and analysis of nine fluoroquinolones in a complex sample by liquid chromatography coupled to quadrupole linear ion trap mass spectrometry (LC-QqQ LIT -MS/MS). The adsorbent was prepared conveniently by functionalizing Fe 3 O 4 @SiO 2 microspheres with phenyl and tetrazolyl groups, which could adsorb fluoroquinolones selectively via hydrophobic, electrostatic, and π-π interactions. The established magnetic solid-phase extraction (MSPE) method as well as using stable isotope labeled internal standards in the next MS/MS detection was able to reduce the matrix effect significantly. In the process of LC-QqQ LIT -MS/MS analysis, the precursor and product ions of the analytes were monitored quantitatively and qualitatively on a QTrap system equipped simultaneously with the multiple reaction monitoring (MRM) and enhanced product ion (EPI) scan. Subsequently, the enrichment method combined with LC-QqQ LIT -MS/MS demonstrated good analytical features in terms of linearity (7.5-100.0 ng mL -1 , r > 0.9960), satisfactory recoveries (88.6%-118.3%) with RSDs < 12.0%, LODs = 0.5 μg kg -1 and LOQs = 1.5 μg kg -1 for all tested analytes. Finally, the developed MSPE-LC-QqQ LIT -MS/MS method had been successfully applied to real pork samples for food-safety risk monitoring in Ningxia Province, China. Graphical abstract Mechanism of reducing matrix effect through the as-prepared adsorbent.
van den Besselaar, A M H P; Chantarangkul, V; Angeloni, F; Binder, N B; Byrne, M; Dauer, R; Gudmundsdottir, B R; Jespersen, J; Kitchen, S; Legnani, C; Lindahl, T L; Manning, R A; Martinuzzo, M; Panes, O; Pengo, V; Riddell, A; Subramanian, S; Szederjesi, A; Tantanate, C; Herbel, P; Tripodi, A
2018-01-01
Essentials Two candidate International Standards for thromboplastin (coded RBT/16 and rTF/16) are proposed. International Sensitivity Index (ISI) of proposed standards was assessed in a 20-centre study. The mean ISI for RBT/16 was 1.21 with a between-centre coefficient of variation of 4.6%. The mean ISI for rTF/16 was 1.11 with a between-centre coefficient of variation of 5.7%. Background The availability of International Standards for thromboplastin is essential for the calibration of routine reagents and hence the calculation of the International Normalized Ratio (INR). Stocks of the current Fourth International Standards are running low. Candidate replacement materials have been prepared. This article describes the calibration of the proposed Fifth International Standards for thromboplastin, rabbit, plain (coded RBT/16) and for thromboplastin, recombinant, human, plain (coded rTF/16). Methods An international collaborative study was carried out for the assignment of International Sensitivity Indexes (ISIs) to the candidate materials, according to the World Health Organization (WHO) guidelines for thromboplastins and plasma used to control oral anticoagulant therapy with vitamin K antagonists. Results Results were obtained from 20 laboratories. In several cases, deviations from the ISI calibration model were observed, but the average INR deviation attributabled to the model was not greater than 10%. Only valid ISI assessments were used to calculate the mean ISI for each candidate. The mean ISI for RBT/16 was 1.21 (between-laboratory coefficient of variation [CV]: 4.6%), and the mean ISI for rTF/16 was 1.11 (between-laboratory CV: 5.7%). Conclusions The between-laboratory variation of the ISI for candidate material RBT/16 was similar to that of the Fourth International Standard (RBT/05), and the between-laboratory variation of the ISI for candidate material rTF/16 was slightly higher than that of the Fourth International Standard (rTF/09). The candidate materials have been accepted by WHO as the Fifth International Standards for thromboplastin, rabbit plain, and thromboplastin, recombinant, human, plain. © 2017 International Society on Thrombosis and Haemostasis.
Cífková, Eva; Holčapek, Michal; Lísa, Miroslav; Ovčačíková, Magdaléna; Lyčka, Antonín; Lynen, Frédéric; Sandra, Pat
2012-11-20
The identification and quantitation of a wide range of lipids in complex biological samples is an essential requirement for the lipidomic studies. High-performance liquid chromatography-mass spectrometry (HPLC/MS) has the highest potential to obtain detailed information on the whole lipidome, but the reliable quantitation of multiple lipid classes is still a challenging task. In this work, we describe a new method for the nontargeted quantitation of polar lipid classes separated by hydrophilic interaction liquid chromatography (HILIC) followed by positive-ion electrospray ionization mass spectrometry (ESI-MS) using a single internal lipid standard to which all class specific response factors (RFs) are related to. The developed method enables the nontargeted quantitation of lipid classes and molecules inside these classes in contrast to the conventional targeted quantitation, which is based on predefined selected reaction monitoring (SRM) transitions for selected lipids only. In the nontargeted quantitation method described here, concentrations of lipid classes are obtained by the peak integration in HILIC chromatograms multiplied by their RFs related to the single internal standard (i.e., sphingosyl PE, d17:1/12:0) used as common reference for all polar lipid classes. The accuracy, reproducibility and robustness of the method have been checked by various means: (1) the comparison with conventional lipidomic quantitation using SRM scans on a triple quadrupole (QqQ) mass analyzer, (2) (31)P nuclear magnetic resonance (NMR) quantitation of the total lipid extract, (3) method robustness test using subsequent measurements by three different persons, (4) method transfer to different HPLC/MS systems using different chromatographic conditions, and (5) comparison with previously published results for identical samples, especially human reference plasma from the National Institute of Standards and Technology (NIST human plasma). Results on human plasma, egg yolk and porcine liver extracts are presented and discussed.
Code of Federal Regulations, 2010 CFR
2010-07-01
... I am a manufacturer of stationary SI internal combustion engines or equipment containing such... Stationary Spark Ignition Internal Combustion Engines Emission Standards for Manufacturers § 60.4231 What emission standards must I meet if I am a manufacturer of stationary SI internal combustion engines or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... I am a manufacturer of stationary SI internal combustion engines or equipment containing such... Stationary Spark Ignition Internal Combustion Engines Emission Standards for Manufacturers § 60.4231 What emission standards must I meet if I am a manufacturer of stationary SI internal combustion engines or...
Code of Federal Regulations, 2014 CFR
2014-07-01
... I am a manufacturer of stationary SI internal combustion engines or equipment containing such... Stationary Spark Ignition Internal Combustion Engines Emission Standards for Manufacturers § 60.4231 What emission standards must I meet if I am a manufacturer of stationary SI internal combustion engines or...
Code of Federal Regulations, 2011 CFR
2011-07-01
... I am a manufacturer of stationary SI internal combustion engines or equipment containing such... Stationary Spark Ignition Internal Combustion Engines Emission Standards for Manufacturers § 60.4231 What emission standards must I meet if I am a manufacturer of stationary SI internal combustion engines or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... I am a manufacturer of stationary SI internal combustion engines or equipment containing such... Stationary Spark Ignition Internal Combustion Engines Emission Standards for Manufacturers § 60.4231 What emission standards must I meet if I am a manufacturer of stationary SI internal combustion engines or...
Code of Federal Regulations, 2010 CFR
2010-04-01
... reconciliation process; (ii) Pull tabs, including but not limited to, statistical records, winner verification... 25 Indians 2 2010-04-01 2010-04-01 false What are the minimum internal control standards for... COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.42 What are...
CMMI(Registered) for Acquisition, Version 1.3. CMMI-ACQ, V1.3
2010-11-01
and Software Engineering – System Life Cycle Processes [ ISO 2008b] ISO /IEC 27001 :2005 Information technology – Security techniques – Information...International Organization for Standardization and International Electrotechnical Commission. ISO /IEC 27001 Information Technology – Security Techniques...International Organization for Standardization/International Electrotechnical Commission ( ISO /IEC) body of standards. CMMs focus on improving processes
Efforts to improve international migration statistics: a historical perspective.
Kraly, E P; Gnanasekaran, K S
1987-01-01
During the past decade, the international statistical community has made several efforts to develop standards for the definition, collection and publication of statistics on international migration. This article surveys the history of official initiatives to standardize international migration statistics by reviewing the recommendations of the International Statistical Institute, International Labor Organization, and the UN, and reports a recently proposed agenda for moving toward comparability among national statistical systems. Heightening awareness of the benefits of exchange and creating motivation to implement international standards requires a 3-pronged effort from the international statistical community. 1st, it is essential to continue discussion about the significance of improvement, specifically standardization, of international migration statistics. The move from theory to practice in this area requires ongoing focus by migration statisticians so that conformity to international standards itself becomes a criterion by which national statistical practices are examined and assessed. 2nd, the countries should be provided with technical documentation to support and facilitate the implementation of the recommended statistical systems. Documentation should be developed with an understanding that conformity to international standards for migration and travel statistics must be achieved within existing national statistical programs. 3rd, the call for statistical research in this area requires more efforts by the community of migration statisticians, beginning with the mobilization of bilateral and multilateral resources to undertake the preceding list of activities.
The standards process: X3 information processing systems
NASA Technical Reports Server (NTRS)
Emard, Jean-Paul
1993-01-01
The topics are presented in viewgraph form and include the following: International Organization for Standards (ISO); International Electrotechnical Committee (IEC); ISO/IEC Joint Technical Committee 1 (JTC-1); U.S. interface to JTC-1; ANSI; national organizations; U.S. standards development processes; national and international standards developing organizations; regional organizations; and X3 information processing systems.
Huang, Min; Winters, Doug; Crowley, Richard; Sullivan, Darryl
2009-01-01
A method has been developed for the simultaneous measurement of multiple B vitamins (i.e., B1, B2, B3, B5, and B6) in infant formulas by LC-MSIMS. The vitamins were extracted with acidic solvent, followed by protein precipitation at a pH range of 4.5 to 5.5, and filtered. This simplified procedure eliminates many of the potential sources of laboratory error and facilitates rapid and efficient analysis. As is common in most cases, isotope internal standards were added to account for variations in sample preparation, as well as changes in MS measurement. In this method, isotope-labeled internal standards of B1, B3, B5, and B6 were used. The factors affecting analytical performance were investigated and optimized. In addition, the stability of these vitamins in the extraction solution was investigated. An acidic condition (5 mM HCl) was applied to successfully stabilize B1, which had shown a decrease in signal when other solvents were used. The quantitative extraction and good stability allowed isotope standards to be added to the filtered sample solution, instead of to the extraction solvent. The addition of the isotope to the small portion of the filtered sample solution significantly reduces cost. A comprehensive evaluation of the analysis of the standard reference material and good spike recovery of the vitamins (100 +/- 6%) demonstrates the accuracy of the method. The results for commercially available infant formula samples were also compared with those obtained using the current microbiological method.
International Micrographics Standards: Report of the 1979 Paris Meeting of ISO/TC171.
ERIC Educational Resources Information Center
Heynen, Jeffrey
1980-01-01
Describes a meeting of the technical committee on micrographics of the International Organization for Standardization, and fcuses on the committee's work relating to the reproduction of library materials within the general context of international standards-making activities. (FM)
Faculty Perspectives on International Accounting Topics.
ERIC Educational Resources Information Center
Smith, L. Murphy; Salter, Stephen B.
1996-01-01
A survey of 63 professors specializing in international accounting identified the following topics as most important to incorporate into the curriculum: (1) foreign currency translation; (2) international accounting standards; (3) comparative standards and harmonizing of accounting standards; (4) reporting and disclosure problems of multinational…
Multi-Sensor Fusion with Interacting Multiple Model Filter for Improved Aircraft Position Accuracy
Cho, Taehwan; Lee, Changho; Choi, Sangbang
2013-01-01
The International Civil Aviation Organization (ICAO) has decided to adopt Communications, Navigation, and Surveillance/Air Traffic Management (CNS/ATM) as the 21st century standard for navigation. Accordingly, ICAO members have provided an impetus to develop related technology and build sufficient infrastructure. For aviation surveillance with CNS/ATM, Ground-Based Augmentation System (GBAS), Automatic Dependent Surveillance-Broadcast (ADS-B), multilateration (MLAT) and wide-area multilateration (WAM) systems are being established. These sensors can track aircraft positions more accurately than existing radar and can compensate for the blind spots in aircraft surveillance. In this paper, we applied a novel sensor fusion method with Interacting Multiple Model (IMM) filter to GBAS, ADS-B, MLAT, and WAM data in order to improve the reliability of the aircraft position. Results of performance analysis show that the position accuracy is improved by the proposed sensor fusion method with the IMM filter. PMID:23535715
Multi-sensor fusion with interacting multiple model filter for improved aircraft position accuracy.
Cho, Taehwan; Lee, Changho; Choi, Sangbang
2013-03-27
The International Civil Aviation Organization (ICAO) has decided to adopt Communications, Navigation, and Surveillance/Air Traffic Management (CNS/ATM) as the 21st century standard for navigation. Accordingly, ICAO members have provided an impetus to develop related technology and build sufficient infrastructure. For aviation surveillance with CNS/ATM, Ground-Based Augmentation System (GBAS), Automatic Dependent Surveillance-Broadcast (ADS-B), multilateration (MLAT) and wide-area multilateration (WAM) systems are being established. These sensors can track aircraft positions more accurately than existing radar and can compensate for the blind spots in aircraft surveillance. In this paper, we applied a novel sensor fusion method with Interacting Multiple Model (IMM) filter to GBAS, ADS-B, MLAT, and WAM data in order to improve the reliability of the aircraft position. Results of performance analysis show that the position accuracy is improved by the proposed sensor fusion method with the IMM filter.
Dose-response relationships in multifunctional food design: assembling the evidence.
Aggett, Peter J
2012-03-01
Demonstrating single and multiple functions attributable to foods or specific food components is a challenge. The International Life Sciences Institute Europe co-ordinated EU concerted actions, Functional Food Science in Europe (FUFOSE) and the Process for the Assessment of Scientific Support for Claims on Food (PASSCLAIM), respectively, addressed the soundness of the evidence and its coherence with a mechanistic schema comprising valid markers of exposure, intermediate and final outcomes and the quality and integrity of the evidence overall. Demonstrating causality often relies on randomized controlled trials (RCTs). However, in public health and biomedical science there is concern about the suitability of RCTs as sole standards of evidence-based approaches. Alternative and complementary approaches using updated Hill's viewpoints for appraising the evidence can be used in conjunction with evidence-based mechanistic reasoning and the quality criteria proposed in FUFOSE and PASSCLAIM to design studies and to assemble evidence exploring single or multiple benefits from food components and foods.
Dziadosz, Marek
2018-05-01
Multiple analyte adduct formation was examined and discussed in the context of reproducible signal detection in liquid chromatography-tandem mass spectrometry applied in the analysis of biologically-related samples. Appropriate infusion solutions were prepared in H 2 O/methanol (3/97, v/v) with 1 mM sodium acetate and 10 mM acetic acid. An API 4000 QTrap tandem mass spectrometer was used for experiments performed in the negative scan mode (-Q1 MS) and the negative enhanced product ion mode (-EPI). γ‑Hydroxybutyrate and its deuterated form were used as model compounds to highlight both the complexity of adduct formation in popular mobile phases used and the effective signal compensation by the application of isotope-labelled analytes as internal standards. Copyright © 2018 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-04-01
... but not limited to, bingo card control, payout procedures, and cash reconciliation process; (ii) Pull... 25 Indians 2 2010-04-01 2010-04-01 false What are the minimum internal control standards for... COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.22 What are...
Code of Federal Regulations, 2010 CFR
2010-04-01
... but not limited to, bingo card control, payout procedures, and cash reconciliation process; (ii) Pull... 25 Indians 2 2010-04-01 2010-04-01 false What are the minimum internal control standards for... COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.32 What are...
Pagliusi, Sonia R; Dillner, Joakim; Pawlita, Michael; Quint, Wim G V; Wheeler, Cosette M; Ferguson, M
2006-08-31
International reference materials such as International Standard reagents facilitate quality assurance of essential biopharmaceutical products and related in vitro diagnostic tests. Standardization of antibody and DNA measurements and harmonization of laboratory procedures are key to the success of cancer prevention strategies through screening methods as well as for development and implementation of vaccination against the human papillomavirus (HPV). The WHO supported the preparation and initial analysis of a panel of candidate serological and DNA reference reagents aimed at facilitating inter-laboratory comparisons and detection of HPV worldwide. Two international collaborative studies assessed the performance of various HPV antibody and HPV-DNA detection assays and examined the feasibility of generating HPV antibody and DNA standard reagents. These studies showed that improvement in performance and comparability of assays is urgently needed and that the use of the same International Standard reference reagent could significantly improve performance and comparability. It is hoped that the establishment of International Units and International Standards for HPV antibody and DNA analysis will be pursued with high priority.
Housekeeping genes as internal standards: use and limits.
Thellin, O; Zorzi, W; Lakaye, B; De Borman, B; Coumans, B; Hennen, G; Grisar, T; Igout, A; Heinen, E
1999-10-08
Quantitative studies are commonly realised in the biomedical research to compare RNA expression in different experimental or clinical conditions. These quantifications are performed through their comparison to the expression of the housekeeping gene transcripts like glyceraldehyde-3-phosphate dehydrogenase (G3PDH), albumin, actins, tubulins, cyclophilin, hypoxantine phsophoribosyltransferase (HRPT), L32. 28S, and 18S rRNAs are also used as internal standards. In this paper, it is recalled that the commonly used internal standards can quantitatively vary in response to various factors. Possible variations are illustrated using three experimental examples. Preferred types of internal standards are then proposed for each of these samples and thereafter the general procedure concerning the choice of an internal standard and the way to manage its uses are discussed.
Issues concerning international comparison of free-field calibrations of acoustical standards
NASA Astrophysics Data System (ADS)
Nedzelnitsky, Victor
2002-11-01
Primary free-field calibrations of laboratory standard microphones by the reciprocity method establish these microphones as reference standard devices for calibrating working standard microphones, other measuring microphones, and practical instruments such as sound level meters and personal sound exposure meters (noise dosimeters). These primary, secondary, and other calibrations are indispensable to the support of regulatory requirements, standards, and product characterization and quality control procedures important for industry, commerce, health, and safety. International Electrotechnical Commission (IEC) Technical Committee 29 Electroacoustics produces international documentary standards, including standards for primary and secondary free-field calibration and measurement procedures and their critically important application to practical instruments. This paper addresses some issues concerning calibrations, standards activities, and the international key comparison of primary free-field calibrations of IEC-type LS2 laboratory standard microphones that is being planned by the Consultative Committee for Acoustics, Ultrasound, and Vibration (CCAUV) of the International Committee for Weights and Measures (CIPM). This comparison will include free-field calibrations by the reciprocity method at participating major national metrology laboratories throughout the world.
International standards in mitigating trade risks.
Thiermann, A B
2011-04-01
This paper describes the role of the World Organisation for Animal Health (OIE), as a science-based and democratic standard-setting organisation that provides guidance on preventing the spread of animal diseases, including zoonoses, in international trade. The World Trade Organization is identified as the international institution with the legal power to encourage adherence to international standards and mediate trade disputes. The importance of assuring good governance and the credibility of national Veterinary Services through a process of official certification is identified as an essential component in the safety of trade. Private-public partnerships and the evolution of responsibilities are also identified as essential for the implementation of health guarantees such as compartmentalisation. The rapid emergence of private standards is described as a potential complement to the implementation of sanitary standards, as long as they are applied globally and in support of the OIE standards. Ultimately, the biggest challenge is for the international community to create the incentives and generate the political will for fair trade and for the universal recognition and application of the established international sanitary standards.
78 FR 59372 - Certain Multiple Mode Outdoor Grills and Parts Thererof; Institution of Investigation
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-26
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-895] Certain Multiple Mode Outdoor Grills and Parts Thererof; Institution of Investigation AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that a complaint was filed with the U.S. International Trade...
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission standards if I am a manufacturer of stationary SI internal combustion engines? 60.4232 Section 60... Internal Combustion Engines Emission Standards for Manufacturers § 60.4232 How long must my engines meet the emission standards if I am a manufacturer of stationary SI internal combustion engines? Engines...
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission standards if I am a manufacturer of stationary SI internal combustion engines? 60.4232 Section 60... Internal Combustion Engines Emission Standards for Manufacturers § 60.4232 How long must my engines meet the emission standards if I am a manufacturer of stationary SI internal combustion engines? Engines...
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission standards if I am a manufacturer of stationary SI internal combustion engines? 60.4232 Section 60... Internal Combustion Engines Emission Standards for Manufacturers § 60.4232 How long must my engines meet the emission standards if I am a manufacturer of stationary SI internal combustion engines? Engines...
Code of Federal Regulations, 2010 CFR
2010-07-01
... emission standards if I am a stationary CI internal combustion engine manufacturer? 60.4203 Section 60.4203... Combustion Engines Emission Standards for Manufacturers § 60.4203 How long must my engines meet the emission standards if I am a stationary CI internal combustion engine manufacturer? Engines manufactured by...
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission standards if I am a stationary CI internal combustion engine manufacturer? 60.4203 Section 60.4203... Combustion Engines Emission Standards for Manufacturers § 60.4203 How long must my engines meet the emission standards if I am a stationary CI internal combustion engine manufacturer? Engines manufactured by...
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission standards if I am a manufacturer of stationary CI internal combustion engines? 60.4203 Section 60... Ignition Internal Combustion Engines Emission Standards for Manufacturers § 60.4203 How long must my engines meet the emission standards if I am a manufacturer of stationary CI internal combustion engines...
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission standards if I am a manufacturer of stationary CI internal combustion engines? 60.4203 Section 60... Ignition Internal Combustion Engines Emission Standards for Manufacturers § 60.4203 How long must my engines meet the emission standards if I am a manufacturer of stationary CI internal combustion engines...
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission standards if I am a manufacturer of stationary SI internal combustion engines? 60.4232 Section 60... Internal Combustion Engines Emission Standards for Manufacturers § 60.4232 How long must my engines meet the emission standards if I am a manufacturer of stationary SI internal combustion engines? Engines...
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission standards if I am a manufacturer of stationary CI internal combustion engines? 60.4203 Section 60... Ignition Internal Combustion Engines Emission Standards for Manufacturers § 60.4203 How long must my engines meet the emission standards if I am a manufacturer of stationary CI internal combustion engines...
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission standards if I am a manufacturer of stationary SI internal combustion engines? 60.4232 Section 60... Internal Combustion Engines Emission Standards for Manufacturers § 60.4232 How long must my engines meet the emission standards if I am a manufacturer of stationary SI internal combustion engines? Engines...
ERIC Educational Resources Information Center
International Language Testing Association.
The Task Force on Testing Standards (TFTS) of the International Language Testing Association was charged to produce a report of an international survey of language assessment standards, to provide for exchange of information on standards and for development of a code of practice. Contact with individuals in both language testing and the broader…
Simeone, Piero; Valentini, Pier Paolo; Pizzoferrato, Roberto; Scudieri, Folco
2011-01-01
The purpose of this in vitro study was to compare the dimensional accuracy of the pickup impression technique using a modular individual tray (MIT) and using a standard individual tray (ST) for multiple internal-connection implants. The roles of both materials and geometric misfits were considered. First, because the MIT relies on the stiffness and elasticity of acrylic resin material, a preliminary investigation of the resin volume contraction during curing and polymerization was done. Then, two sets of specimens were tested to compare the accuracy of the MIT (test group) to that of the ST (control group). The linear and angular displacements of the transfer copings were measured and compared during three different stages of the impression procedure. Experimental measurements were performed with a computerized coordinate measuring machine. The curing dynamic of the acrylic resin was strongly dependent on the physical properties of the acrylic material and the powder/liquid ratio. Specifically, an increase in the powder/liquid ratio accelerated resin polymerization (curing time decreases by 70%) and reduced the final volume contraction by 45%. However, the total shrinkage never exceeded the elastic limits of the material; hence, it did not affect the coping's stability. In the test group, linear errors were reduced by 55% and angular errors were reduced by 65%. Linear and angular displacements of the transfer copings were significantly reduced with the MIT technique, which led to higher dimensional accuracy versus the ST group. The MIT approach, in combination with a thin and uniform amount of acrylic resin in the pickup impression technique, showed no significant permanent distortions in multiple misalignment internal-connection implants compared to the ST technique.
46 CFR 108.503 - Relationship to international standards.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Relationship to international standards. 108.503 Section 108.503 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Lifesaving Equipment § 108.503 Relationship to international standards. For...
Third International Standard for Posterior Pituitary
Bangham, D. R.; Mussett, Marjorie V.
1958-01-01
In October 1955, stocks of the Second International Standard for Posterior Pituitary were running low and the Department of Biological Standards of the National Institute for Medical Research, London, was asked to proceed with the arrangements for an international collaborative assay of material for the Third Standard. A single 142-g batch of posterior-pituitary-lobe powder was obtained and distributed in ampoules, in approximately 30-mg quantities. Samples were sent to 19 laboratories in 10 countries. In all, 185 assays were carried out, 122 for oxytocic activity, 53 for vasopressor activity and 10 for antidiuretic activity. On the basis of the results, which were analysed statistically at the National Institute for Medical Research, it was agreed that the potency of the Third Standard (re-named International Standard for Oxytocic, Vasopressor and Antidiuretic Substances in 1956, in view of the recent synthesis of oxytocin and vasopressin) should be expressed as 2.0 International Units per milligram. The International Unit therefore remains unchanged as 0.5 mg of the dry powder. PMID:13585079
Evidences to validate public policies: a review with an international research perspective.
Gregori, Dario
2014-01-01
Nutrition and related health issues are nowadays topics of general interest. The prevalence of overweight and obesity has increased with alarming speed over the past twenty years, being described by the World Health Organization as a global epidemic. An evidence-based approach to public health interventions should be based on the best available information. Given the substantial investment of society in fundamental and applied health research, and the high expectations of society for reducing the burden of illness, attention to these matters should have high priority. There's an urgent need to foster the development of international standards, such as food labeling and profiling. Considering the complex network involved in obesity development, it is necessary to promote multiple-concurrent interventions, taking into account that by focusing on a single intervention in isolation, all other factors being constant, each individual policy change is likely to appear ineffective.
Evolution and convergence of the patterns of international scientific collaboration.
Coccia, Mario; Wang, Lili
2016-02-23
International research collaboration plays an important role in the social construction and evolution of science. Studies of science increasingly analyze international collaboration across multiple organizations for its impetus in improving research quality, advancing efficiency of the scientific production, and fostering breakthroughs in a shorter time. However, long-run patterns of international research collaboration across scientific fields and their structural changes over time are hardly known. Here we show the convergence of international scientific collaboration across research fields over time. Our study uses a dataset by the National Science Foundation and computes the fraction of papers that have international institutional coauthorships for various fields of science. We compare our results with pioneering studies carried out in the 1970s and 1990s by applying a standardization method that transforms all fractions of internationally coauthored papers into a comparable framework. We find, over 1973-2012, that the evolution of collaboration patterns across scientific disciplines seems to generate a convergence between applied and basic sciences. We also show that the general architecture of international scientific collaboration, based on the ranking of fractions of international coauthorships for different scientific fields per year, has tended to be unchanged over time, at least until now. Overall, this study shows, to our knowledge for the first time, the evolution of the patterns of international scientific collaboration starting from initial results described by literature in the 1970s and 1990s. We find a convergence of these long-run collaboration patterns between the applied and basic sciences. This convergence might be one of contributing factors that supports the evolution of modern scientific fields.
van Tongeren, Martie
2013-01-01
The INTEROCC project is a multi-centre case–control study investigating the risk of developing brain cancer due to occupational chemical and electromagnetic field exposures. To estimate chemical exposures, the Finnish Job Exposure Matrix (FINJEM) was modified to improve its performance in the INTEROCC study and to address some of its limitations, resulting in the development of the INTEROCC JEM. An international team of occupational hygienists developed a crosswalk between the Finnish occupational codes used in FINJEM and the International Standard Classification of Occupations 1968 (ISCO68). For ISCO68 codes linked to multiple Finnish codes, weighted means of the exposure estimates were calculated. Similarly, multiple ISCO68 codes linked to a single Finnish code with evidence of heterogeneous exposure were refined. One of the key time periods in FINJEM (1960–1984) was split into two periods (1960–1974 and 1975–1984). Benzene exposure estimates in early periods were modified upwards. The internal consistency of hydrocarbon exposures and exposures to engine exhaust fumes was improved. Finally, exposure to polycyclic aromatic hydrocarbon and benzo(a)pyrene was modified to include the contribution from second-hand smoke. The crosswalk ensured that the FINJEM exposure estimates could be applied to the INTEROCC study subjects. The modifications generally resulted in an increased prevalence of exposure to chemical agents. This increased prevalence of exposure was not restricted to the lowest categories of cumulative exposure, but was seen across all levels for some agents. Although this work has produced a JEM with important improvements compared to FINJEM, further improvements are possible with the expansion of agents and additional external data. PMID:23467593
Electronic Health Records Data and Metadata: Challenges for Big Data in the United States.
Sweet, Lauren E; Moulaison, Heather Lea
2013-12-01
This article, written by researchers studying metadata and standards, represents a fresh perspective on the challenges of electronic health records (EHRs) and serves as a primer for big data researchers new to health-related issues. Primarily, we argue for the importance of the systematic adoption of standards in EHR data and metadata as a way of promoting big data research and benefiting patients. EHRs have the potential to include a vast amount of longitudinal health data, and metadata provides the formal structures to govern that data. In the United States, electronic medical records (EMRs) are part of the larger EHR. EHR data is submitted by a variety of clinical data providers and potentially by the patients themselves. Because data input practices are not necessarily standardized, and because of the multiplicity of current standards, basic interoperability in EHRs is hindered. Some of the issues with EHR interoperability stem from the complexities of the data they include, which can be both structured and unstructured. A number of controlled vocabularies are available to data providers. The continuity of care document standard will provide interoperability in the United States between the EMR and the larger EHR, potentially making data input by providers directly available to other providers. The data involved is nonetheless messy. In particular, the use of competing vocabularies such as the Systematized Nomenclature of Medicine-Clinical Terms, MEDCIN, and locally created vocabularies inhibits large-scale interoperability for structured portions of the records, and unstructured portions, although potentially not machine readable, remain essential. Once EMRs for patients are brought together as EHRs, the EHRs must be managed and stored. Adequate documentation should be created and maintained to assure the secure and accurate use of EHR data. There are currently a few notable international standards initiatives for EHRs. Organizations such as Health Level Seven International and Clinical Data Interchange Standards Consortium are developing and overseeing implementation of interoperability standards. Denmark and Singapore are two countries that have successfully implemented national EHR systems. Future work in electronic health information initiatives should underscore the importance of standards and reinforce interoperability of EHRs for big data research and for the sake of patients.
Design and synthesis of multiple antigenic peptides and their application for dengue diagnosis.
Rai, Reeta; Dubey, Sameer; Santosh, K V; Biswas, Ashutosh; Mehrotra, Vinit; Rao, D N
2017-09-01
Major difficulty in development of dengue diagnostics is availability of suitable antigens. To overcome this, we made an attempt to develop a peptide based diagnosis which offers significant advantage over other methods. With the help of in silico methods, two epitopes were selected from envelope protein and three from NS1 protein of dengue virus. These were synthesized in combination as three multiple antigenic peptides (MAPs). We have tested 157 dengue positive sera confirmed for NS1 antigen. MAP1 showed 96.81% sera positive for IgM and 68.15% positive for IgG. MAP2 detected 94.90% IgM and 59.23% IgG positive sera. MAP3 also detected 96.17% IgM and 59.87% IgG positive sera. To the best of our knowledge this is the first study describing the use of synthetic multiple antigenic peptides for the diagnosis of dengue infection. This study describes MAPs as a promising tool for the use in serodiagnosis of dengue. Copyright © 2017 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.
Radiation safety standards and their application: international policies and current issues.
González, Abel J
2004-09-01
This paper briefly describes the current policies of the United Nations Scientific Committee on the Effects of Atomic Radiation and the International Commission on Radiological Protection and how these policies are converted into international radiation safety standards by the International Atomic Energy Agency, which is the only global organization-within the United Nations family of international agencies-with a statutory mandate not only to establish such standards but also to provide for their application. It also summarizes the current status of the established corpus of such international standards, and of it foreseeable evolution, as well as of legally binding undertakings by countries around the world that are linked to these standards. Moreover, this paper also reviews some major current global issues related to the application of international standards, including the following: strengthening of national infrastructures for radiation safety, including technical cooperation programs for assisting developing countries; occupational radiation safety challenges, including the protection of pregnant workers and their unborn children, dealing with working environments with high natural radiation levels, and occupational attributability of health effects (probability of occupational causation); restricting discharges of radioactive substances into the environment: reviewing current international policies vis-a-vis the growing concern on the radiation protection of the "environment;" radiological protection of patients undergoing radiodiagnostic and radiotherapeutic procedures: the current International Action Plan; safety and security of radiation sources: post-11 September developments; preparedness and response to radiation emergencies: enhancing the international network; safe transport of radioactive materials: new apprehensions; safety of radioactive waste management: concerns and connections with radiation protection; and radioactive residues remaining after the termination of activities: radiation protection response to the forthcoming wave of decommissioning of installations with radioactive materials. The ultimate aim of this paper is to encourage information exchange, cooperation, and collaboration within the radiation protection professional community. In particular, the paper tries to facilitate consolidation of the growing international regime on radiation safety, including the expansion of legally binding undertakings by countries, the strengthening of the current corpus of international radiation safety standards, and the development of international provisions for ensuring the proper worldwide application of these standards, such as a system of international appraisals by peer review.
46 CFR 133.03 - Relationship to international standards.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Relationship to international standards. 133.03 Section 133.03 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS General § 133.03 Relationship to international standards. This subpart and subpart B of...
77 FR 60625 - Minimum Internal Control Standards for Class II Gaming
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-04
...-37 Minimum Internal Control Standards for Class II Gaming AGENCY: National Indian Gaming Commission... Internal Control Standards that were published on September 21, 2012. DATES: The effective date [email protected] . FOR FURTHER INFORMATION CONTACT: Jennifer Ward, Attorney, NIGC Office of General Counsel, at...
46 CFR 133.03 - Relationship to international standards.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Relationship to international standards. 133.03 Section 133.03 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS General § 133.03 Relationship to international standards. This subpart and subpart B of...
46 CFR 133.03 - Relationship to international standards.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Relationship to international standards. 133.03 Section 133.03 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS General § 133.03 Relationship to international standards. This subpart and subpart B of...
46 CFR 133.03 - Relationship to international standards.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Relationship to international standards. 133.03 Section 133.03 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS General § 133.03 Relationship to international standards. This subpart and subpart B of...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for patron deposit accounts and cashless systems? 543.14 Section 543.14 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.14 What are the minimum internal control...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 2 2010-04-01 2010-04-01 false How do these regulations affect minimum internal control standards established in a Tribal-State compact? 542.4 Section 542.4 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.4 How do these regulations affect minimum internal...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 2 2011-04-01 2011-04-01 false How do these regulations affect minimum internal control standards established in a Tribal-State compact? 542.4 Section 542.4 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.4 How do these regulations affect minimum internal...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for gaming promotions and player tracking systems? 543.12 Section 543.12 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.12 What are the minimum internal contro...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false How do these regulations affect minimum internal control standards established in a Tribal-State compact? 542.4 Section 542.4 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.4 How do these regulations affect minimum internal...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 2 2012-04-01 2012-04-01 false How do these regulations affect minimum internal control standards established in a Tribal-State compact? 542.4 Section 542.4 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.4 How do these regulations affect minimum internal...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for patron deposit accounts and cashless systems? 543.14 Section 543.14 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.14 What are the minimum internal control...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false How do these regulations affect minimum internal control standards established in a Tribal-State compact? 542.4 Section 542.4 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.4 How do these regulations affect minimum internal...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for gaming promotions and player tracking systems? 543.12 Section 543.12 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.12 What are the minimum internal contro...
Citizen Science: Data Sharing For, By, and With the Public
NASA Astrophysics Data System (ADS)
Wiggins, A.
2017-12-01
Data sharing in citizen science is just as challenging as it is for any other type of science, except that there are more parties involved, with more diverse needs and interests. This talk provides an overview of the challenges and current efforts to advance data sharing in citizen science, and suggests refocusing data management activities on supporting the needs of multiple audiences. Early work on data sharing in citizen science advocated applying the standards and practices of academia, which can only address the needs of one of several audiences for citizen science data, and academics are not always the primary audience. Practitioners still need guidance on how to better share data other key parties, such as participants and policymakers, and which data management practices to prioritize for addressing the needs of multiple audiences. The benefits to the project of investing scarce resources into data products and dissemination strategies for each target audience still remain variable, unclear, or unpredictable. And as projects mature and change, the importance of data sharing activities and audiences are likely to change as well. This combination of multiple diverse audiences, shifting priorities, limited resources, and unclear benefits creates a perfect storm of conditions to suppress data sharing. Nonetheless, many citizen science projects make the effort, with exemplars showing substantial returns on data stewardship investments, and international initiatives are underway to bolster the data sharing capacity of the field. To improve the state of data sharing in citizen science, strategic use of limited resources suggests prioritizing data management activities that support the needs of multiple audiences. These may include better transparency about data access and usage, and standardized reporting of broader impacts from secondary data users, to both reward projects and incentivize further data sharing.
Status of international optical disk standards
NASA Astrophysics Data System (ADS)
Chen, Di; Neumann, John
1999-11-01
Optical technology for data storage offers media removability with unsurpassed reliability. As the media are removable, data interchange between the media and drives from different sources is a major concern. The optical recording community realized, at the inception of this new storage technology development, that international standards for all optical recording disk/cartridge must be established to insure the healthy growth of this industry and for the benefit of the users. Many standards organizations took up the challenge and numerous international standards were established which are now being used world-wide. This paper provides a brief summary of the current status of the international optical disk standards.
ERIC Educational Resources Information Center
Ji, Chang; Boisvert, Susanne M.; Arida, Ann-Marie C.; Day, Shannon E.
2008-01-01
An internal standard method applicable to undergraduate instrumental analysis or environmental chemistry laboratory has been designed and tested to determine the Henry's law constants for a series of alkyl nitriles. In this method, a mixture of the analytes and an internal standard is prepared and used to make a standard solution (organic solvent)…
Robinson, D; Zhao, N; Gathany, T; Kim, L-L; Cella, D; Revicki, D
2009-05-01
Baseline clinical and health-related quality of life (HRQoL) data from a phase 2, multi-site, international, randomized, controlled trial were analyzed to: (1) characterize the health status of patients with relapsing-remitting multiple sclerosis (RRMS), (2) explore cross-sectional relationships between HRQoL and clinical measures, and (3) evaluate differences in HRQoL scores for subsequent validation as minimally important differences (MID). www.clinicaltrials.gov, NCT00207727. Baseline clinical and HRQoL data were selected and analyzed. HRQoL questionnaires included the Short Form-36 (SF-36), Fatigue Severity Scale (FSS), a Patient Assessment of multiple sclerosis (MS) Impact (PAMSI), and MS-specific symptom scales for Bladder and Bowel Control, Cognition, and Sexual Satisfaction. Standard summary statistics described the population while Pearson and Spearman correlations evaluated the baseline association between HRQoL and clinical measures. Cross-sectional estimates of MID in HRQoL scores were derived using several clinical anchors, the PAMSI, and two tests: Tukey multiple comparisons and adjacent mean difference. Patients (n = 249) had a mean age of 39.0 (Standard deviation, SD = 10.5), 70% were female, 63% resided in Europe, and 96% were Caucasian. Baseline median Expanded Disability Severity Scale (EDSS) was 2.5 (range = 0.0-6.5); median disease duration was 1.9 years (range = 0.1-33.6). The worst baseline mean (normalized) SF-36 scores were for General Health (39.9), Role Physical (40.4), Physical Functioning (41.0), and Vitality (42.7). The worst MS symptom mean scores were for Cognition (6.3) and FSS (4.4). Fatigue scores indicated substantial burden and were consistent with SF-36 Vitality results. Baseline HRQoL scores (SF-36, FSS, MS symptom scales) correlated most with EDSS, Multiple Sclerosis Functional Composite (MSFC), age and disease duration. Lesion count and pre-baseline relapse rate had no meaningful association with HRQoL or other clinical measures. The MID for several HRQoL measures are proposed for confirmation in longitudinal patient datasets. Clinical and HRQoL assessments documented health impairments in physical functioning, fatigue, and cognition among these RRMS patients with relatively short disease duration. HRQoL data varied with clinical measures and contributed new information regarding disease burden. The association between clinical and HRQoL measures was limited to cross-sectional analysis and requires confirmation in longitudinal datasets. These findings reflect an ambulatory, early-stage RRMS population that was mostly European in location or descent. The PAMSI also requires further validation as a measure of patient health status.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the requirements set forth in §§ 312.23 through 312.31: (a) The procedures of ASTM International... Site Assessment Process.” (b) The procedures of ASTM International Standard E2247-08 entitled “Standard... or Rural Property.” This standard is available from ASTM International at http://www.astm.org, 1-610...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-06
... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Parts 60 and 63 [EPA-HQ-OAR-2008-0708, FRL-9756-4] RIN 2060-AQ58 National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines; New Source Performance Standards for Stationary Internal Combustion Engines Correction In rule...
Internal Standards: A Source of Analytical Bias For Volatile Organic Analyte Determinations
The use of internal standards in the determination of volatile organic compounds as described in SW-846 Method 8260C introduces a potential for bias in results once the internal standards (ISTDs) are added to a sample for analysis. The bias is relative to the dissimilarity betw...
The influence of international standards on optomechanical design
NASA Astrophysics Data System (ADS)
Parks, Robert E.
1992-12-01
In the last 10 to 15 years, a considerable body of international standards literature has been published on both mechanical and optical design. We discuss the influence of these internationally developed standards on the design and fabrication of optical systems. We conclude that while there are large benefits to be gained from using these international standards, there will have to be a substantial educational effort at all levels from project scientist to worker on the shop floor to take advantage of the benefits. Many sources to help in this education process are outlined.
INTERNATIONAL REPORTS: New International Standards for Quantities and Units
NASA Astrophysics Data System (ADS)
Thor, A. J.
1994-01-01
Each coherent system of units is based on a system of quantities in such a way that the equations between the numerical values expressed in coherent units have exactly the same form, including numerical factors, as the corresponding equations between the quantities. The highest international body responsible for the International System of Units (SI) is the Conférence Générale des Poids et Mesures (CGPM). However, the CGPM is not concerned with quantities or systems of quantities. That question lies within the scope of Technical Committee number twelve of the International Organization for Standardization (ISO/TC 12). Quantities, units, symbols, conversion factors. To fulfil its responsibility, ISO/TC 12 has prepared the International Standard ISO 31, Quantities and Units, which consists of fourteen parts. The new editions of the different parts of the International Standard are briefly presented here.
Yeh, Kenneth B; Adams, Martin; Stamper, Paul D; Dasgupta, Debanjana; Hewson, Roger; Buck, Charles D; Richards, Allen L; Hay, John
2016-01-01
Strategic laboratory planning in limited resource areas is essential for addressing global health security issues. Establishing a national reference laboratory, especially one with BSL-3 or -4 biocontainment facilities, requires a heavy investment of resources, a multisectoral approach, and commitments from multiple stakeholders. We make the case for donor organizations and recipient partners to develop a comprehensive laboratory operations roadmap that addresses factors such as mission and roles, engaging national and political support, securing financial support, defining stakeholder involvement, fostering partnerships, and building trust. Successful development occurred with projects in African countries and in Azerbaijan, where strong leadership and a clear management framework have been key to success. A clearly identified and agreed management framework facilitate identifying the responsibility for developing laboratory capabilities and support services, including biosafety and biosecurity, quality assurance, equipment maintenance, supply chain establishment, staff certification and training, retention of human resources, and sustainable operating revenue. These capabilities and support services pose rate-limiting yet necessary challenges. Laboratory capabilities depend on mission and role, as determined by all stakeholders, and demonstrate the need for relevant metrics to monitor the success of the laboratory, including support for internal and external audits. Our analysis concludes that alternative frameworks for success exist for developing and implementing capabilities at regional and national levels in limited resource areas. Thus, achieving a balance for standardizing practices between local procedures and accepted international standards is a prerequisite for integrating new facilities into a country's existing public health infrastructure and into the overall international scientific community.
Parkinson's disease-related fatigue: A case definition and recommendations for clinical research.
Kluger, Benzi M; Herlofson, Karen; Chou, Kelvin L; Lou, Jau-Shin; Goetz, Christopher G; Lang, Anthony E; Weintraub, Daniel; Friedman, Joseph
2016-05-01
Fatigue is one of the most common and disabling symptoms in Parkinson's disease (PD). Since fatigue was first described as a common feature of PD 20 years ago, little progress has been made in understanding its causes or treatment. Importantly, PD patients attending the 2013 World Parkinson Congress voted fatigue as the leading symptom in need of further research. In response, the Parkinson Disease Foundation and ProjectSpark assembled an international team of experts to create recommendations for clinical research to advance this field. The working group identified several areas in which shared standards would improve research quality and foster progress including terminology, diagnostic criteria, and measurement. Terminology needs to (1) clearly distinguish fatigue from related phenomena (eg, sleepiness, apathy, depression); (2) differentiate subjective fatigue complaints from objective performance fatigability; and (3) specify domains affected by fatigue and causal factors. We propose diagnostic criteria for PD-related fatigue to guide participant selection for clinical trials and add rigor to mechanistic studies. Recommendations are made for measurement of subjective fatigue complaints, performance fatigability, and neurophysiologic changes. We also suggest areas in which future research is needed to address methodological issues and validate or optimize current practices. Many limitations in current PD-related fatigue research may be addressed by improving methodological standards, many of which are already being successfully applied in clinical fatigue research in other medical conditions (eg, cancer, multiple sclerosis). © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.
This SOP describes the method used for preparing surrogate recovery standard and internal standard solutions for the analysis of polar target analytes. It also describes the method for preparing calibration standard solutions for polar analytes used for gas chromatography/mass sp...
The population health record: concepts, definition, design, and implementation.
Friedman, Daniel J; Parrish, R Gibson
2010-01-01
In 1997, the American Medical Informatics Association proposed a US information strategy that included a population health record (PopHR). Despite subsequent progress on the conceptualization, development, and implementation of electronic health records and personal health records, minimal progress has occurred on the PopHR. Adapting International Organization for Standarization electronic health records standards, we define the PopHR as a repository of statistics, measures, and indicators regarding the state of and influences on the health of a defined population, in computer processable form, stored and transmitted securely, and accessible by multiple authorized users. The PopHR is based upon an explicit population health framework and a standardized logical information model. PopHR purpose and uses, content and content sources, functionalities, business objectives, information architecture, and system architecture are described. Barriers to implementation and enabling factors and a three-stage implementation strategy are delineated.
Zazzeroni, Raniero; Homan, Andrew; Thain, Emma
2009-08-01
The estimation of the dietary intake of gamma-aminobutyric acid (GABA) is dependent upon the knowledge of its concentration values in food matrices. To this end, an isotope dilution liquid chromatography-mass spectrometry method has been developed employing the hydrophilic interaction chromatography technique for analyte separation. This approach enabled accurate quantification of GABA in apple, potato, soybeans, and orange juice without the need of a pre- or post-column derivatization reaction. A selective and precise analytical measurement has been obtained with a triple quadrupole mass spectrometer operating in multiple reaction monitoring using the method of standard additions and GABA-d(6) as an internal standard. The concentrations of GABA found in the matrices tested are 7 microg/g of apple, 342 microg/g of potatoes, 211 microg/g of soybeans, and 344 microg/mL of orange juice.
Transmission line design for a power distribution system at 20 kHz for aircraft
NASA Technical Reports Server (NTRS)
Zelby, L. W.; Mathes, J. B.; Shawver, J. W.
1986-01-01
A low inductance, low characteristic impedance transmission line was designed for a 20 kHz power distribution system. Several different conductor configurations were considered: strip lines, interdigitated metal ribbons, and standard insulated wires in multiwire configurations (circular and rectangular cylindrical arrangements). The final design was a rectangular arrangement of multiple wires of the same gauge with alternating polarities from wire to wire. This offered the lowest inductance per unit length (on the order of several nanohenries/meter) and the lowest characteristic impedance (on the order of one Ohm). Standard multipin connectors with gold-plated elements were recommended with this transmission line, the junction boxes to be internally connected with flat metal ribbons for low inductance, and the line to be constructed in sections of suitable length. Computer programs for the calculation of inductance of multiwire lines and of capacitances of strip lines were developed.
Astronaut James S. Voss Performs Tasks in the Destiny Laboratory
NASA Technical Reports Server (NTRS)
2001-01-01
Astronaut James S. Voss, Expedition Two flight engineer, works with a series of cables on the EXPRESS Rack in the United State's Destiny laboratory on the International Space Station (ISS). The EXPRESS Rack is a standardized payload rack system that transports, stores, and supports experiments aboard the ISS. EXPRESS stands for EXpedite the PRocessing of Experiments to the Space Station, reflecting the fact that this system was developed specifically to maximize the Station's research capabilities. The EXPRESS Rack system supports science payloads in several disciplines, including biology, chemistry, physics, ecology, and medicine. With the EXPRESS Rack, getting experiments to space has never been easier or more affordable. With its standardized hardware interfaces and streamlined approach, the EXPRESS Rack enables quick, simple integration of multiple payloads aboard the ISS. The system is comprised of elements that remain on the ISS, as well as elements that travel back and forth between the ISS and Earth via the Space Shuttle.
7 CFR 51.1584 - Internal discoloration.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS) United States Consumer Standards for Potatoes Definitions § 51.1584 Internal discoloration..., stem-end browning, internal brown spot, or other similar types of discoloration not visible externally. ...
7 CFR 51.1584 - Internal discoloration.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS) United States Consumer Standards for Potatoes Definitions § 51.1584 Internal discoloration..., stem-end browning, internal brown spot, or other similar types of discoloration not visible externally. ...
Surgical plate fixation of multiple rib fractures: a case report.
Mitev, Konstantin; Neziri, Dashurie; Stoicovski, Emil; Mitrev, Zan
2018-05-29
The healthcare system in developing countries is limited; particularly, medical specialties such as emergency and trauma medicine are underdeveloped. Consequently, trauma injuries sustained in traffic accidents result in chronic morbidity more often than similar cases in developed countries. Multiple rib fractures induce significant patient morbidity. Current international guidelines recommend a multidisciplinary, surgery-based treatment approach to achieve optimal clinical benefit. We admitted a 41-year-old Albanian man to our emergency department following a pedestrian-vehicle accident 5 days earlier. He presented with severe upper thoracic pain, chest deformity, dyspnea, tachycardia, subcutaneous emphysema, and hematoma. Chest radiography pointed to hypoventilated lung fields and a minor pleural effusion. Computed tomographic scans indicated displaced fractures of right lateral ribs 5 -11, hyperdensity regions from bone fragments, and pulmonary contusion. The treatment consisted of surgical fixation of ribs 7-10 using titanium reconstruction plates and cortical locking screws. The patient's clinical condition rapidly improved postoperatively. Follow-up at 6 weeks confirmed a full return to preoperative daily activities and a high quality of life. In this case report, we present a novel and promising development in the field of trauma medicine in the Republic of Macedonia. Trauma injuries can be treated via advanced multidisciplinary medical care according to international standards, allowing optimal health recovery.
Operations and Plans: International Military Rationalization, Standardization, and Interoperability
1989-02-15
Army Regulation 34–1 Operations and Plans International Military Rationalization , Standardization, and Interoperability Headquarters Department of...YYYY) 15-02-1997 2. REPORT TYPE 3. DATES COVERED (FROM - TO) xx-xx-1997 to xx-xx-1997 4. TITLE AND SUBTITLE International Military Rationalization ...DSN 427-9007 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39.18 SUMMARY of CHANGE AR 34–1 International Military Rationalization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Hsin; Bai, Shengqiang; Chen, Lidong
2015-09-03
International transport property measurement round-robins have been conducted by the Thermoelectric Annex under the International Energy Agency (IEA) Implementing Agreement on Advanced Materials for Transportation (AMT). The previous round-robins used commercially available bismuth telluride as the testing material, with the goals of understanding measurement issues and developing standard testing procedures. The current round-robin extended the measurement temperature range to 773 K. It was designed to meet the increasing demands for reliable transport data of thermoelectric materials for power generation applications. Eleven laboratories from six IEA-AMT member countries participated in this study. Half-Heusler (n-type) material prepared by GMZ Energy was selectedmore » for the round-robin. The measured transport properties showed narrower distribution on uncertainties compared to previous round-robin efforts. The study intentionally included multiple testing methods and instrument types. Over the full temperature range, the measurement discrepancies on the figure of merit, ZT, in this round-robin were ±1.5 to ±16.4% from the averages.« less
46 CFR 80.25 - Notification of safety standards.
Code of Federal Regulations, 2014 CFR
2014-10-01
... standards, except the 1966 fire safety standards. (ii) This vessel complies with international safety standards developed prior to 1960. There is (or, is not) an automatic sprinkler system fitted in the... international safety standard. There is (or, is not) an automatic sprinkler system fitted in the passenger...
46 CFR 80.25 - Notification of safety standards.
Code of Federal Regulations, 2012 CFR
2012-10-01
... standards, except the 1966 fire safety standards. (ii) This vessel complies with international safety standards developed prior to 1960. There is (or, is not) an automatic sprinkler system fitted in the... international safety standard. There is (or, is not) an automatic sprinkler system fitted in the passenger...
46 CFR 80.25 - Notification of safety standards.
Code of Federal Regulations, 2013 CFR
2013-10-01
... standards, except the 1966 fire safety standards. (ii) This vessel complies with international safety standards developed prior to 1960. There is (or, is not) an automatic sprinkler system fitted in the... international safety standard. There is (or, is not) an automatic sprinkler system fitted in the passenger...
46 CFR 80.25 - Notification of safety standards.
Code of Federal Regulations, 2011 CFR
2011-10-01
... standards, except the 1966 fire safety standards. (ii) This vessel complies with international safety standards developed prior to 1960. There is (or, is not) an automatic sprinkler system fitted in the... international safety standard. There is (or, is not) an automatic sprinkler system fitted in the passenger...
40 CFR 86.1806-04 - On-board diagnostics.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 2002). (vii) As an alternative to the above standards, heavy-duty vehicles may conform to the... standards shall utilize multiplicative factors from the California vehicle type (i.e. LEV II, ULEV II... standards shall utilize the Tier 2 Bin 4 emission standards and the CARB ULEV II multiplicative factors to...
The International Standard for Oxytetracycline
Humphrey, J. H.; Lightbown, J. W.; Mussett, M. V.; Perry, W. L. M.
1955-01-01
The first attempt to set up an international standard for oxytetracycline, using oxytetracycline hydrochloride, failed because of difficulties in obtaining a preparation whose moisture content was uniform after distribution into ampoules. A preparation of dihydrate of oxytetracycline base was obtained instead, and was compared in an international collaborative assay with a sample of oxytetracycline hydrochloride, which was the current working standard of Chas. Pfizer & Co., Inc., USA. The results of the collaborative assay showed that the potency of the dihydrate was uniform, and that it was a suitable preparation for use as the International Standard. Evidence was obtained, however, that the reference preparation at the time of examination was less potent than had been originally supposed, and that it was hydrated. The potency of the proposed international standard was recalculated after allowance for water in the reference preparation, and the resulting biological potency agreed well with that to be expected on the basis of the physicochemical properties of the preparation. It was agreed, therefore, that the recalculated values should be used, and the preparation of oxytetracycline base dihydrate used in the collaborative assay is established as the International Standard for Oxytetracycline with a potency of 900 International Units per mg. PMID:13284563
Code of Federal Regulations, 2012 CFR
2012-07-01
... standards if I am an owner or operator of a stationary CI internal combustion engine? 60.4206 Section 60... Ignition Internal Combustion Engines Emission Standards for Owners and Operators § 60.4206 How long must I meet the emission standards if I am an owner or operator of a stationary CI internal combustion engine...
Code of Federal Regulations, 2014 CFR
2014-07-01
... standards if I am an owner or operator of a stationary CI internal combustion engine? 60.4206 Section 60... Ignition Internal Combustion Engines Emission Standards for Owners and Operators § 60.4206 How long must I meet the emission standards if I am an owner or operator of a stationary CI internal combustion engine...
Code of Federal Regulations, 2013 CFR
2013-07-01
... standards if I am an owner or operator of a stationary SI internal combustion engine? 60.4234 Section 60... Internal Combustion Engines Emission Standards for Owners and Operators § 60.4234 How long must I meet the emission standards if I am an owner or operator of a stationary SI internal combustion engine? Owners and...
Code of Federal Regulations, 2011 CFR
2011-07-01
... standards if I am an owner or operator of a stationary SI internal combustion engine? 60.4234 Section 60... Internal Combustion Engines Emission Standards for Owners and Operators § 60.4234 How long must I meet the emission standards if I am an owner or operator of a stationary SI internal combustion engine? Owners and...
Code of Federal Regulations, 2013 CFR
2013-07-01
... standards if I am an owner or operator of a stationary CI internal combustion engine? 60.4206 Section 60... Ignition Internal Combustion Engines Emission Standards for Owners and Operators § 60.4206 How long must I meet the emission standards if I am an owner or operator of a stationary CI internal combustion engine...
Code of Federal Regulations, 2014 CFR
2014-07-01
... standards if I am an owner or operator of a stationary SI internal combustion engine? 60.4234 Section 60... Internal Combustion Engines Emission Standards for Owners and Operators § 60.4234 How long must I meet the emission standards if I am an owner or operator of a stationary SI internal combustion engine? Owners and...
Code of Federal Regulations, 2010 CFR
2010-07-01
... standards if I am an owner or operator of a stationary SI internal combustion engine? 60.4234 Section 60... Internal Combustion Engines Emission Standards for Owners and Operators § 60.4234 How long must I meet the emission standards if I am an owner or operator of a stationary SI internal combustion engine? Owners and...
Code of Federal Regulations, 2012 CFR
2012-07-01
... standards if I am an owner or operator of a stationary SI internal combustion engine? 60.4234 Section 60... Internal Combustion Engines Emission Standards for Owners and Operators § 60.4234 How long must I meet the emission standards if I am an owner or operator of a stationary SI internal combustion engine? Owners and...
Toya, Yusuke; Itagaki, Toshiko; Wagatsuma, Kazuaki
2017-01-01
We investigated a simultaneous internal standard method in flame atomic absorption spectrometry (FAAS), in order to better the analytical precision of 3d-transition metals contained in steel materials. For this purpose, a new spectrometer system for FAAS, comprising a bright xenon lamp as the primary radiation source and a high-resolution Echelle monochromator, was employed to measure several absorption lines at a wavelength width of ca. 0.3 nm at the same time, which enables the absorbances of an analytical line and also an internal standard line to be estimated. In considering several criteria for selecting an internal standard element and the absorption line, it could be suggested that platinum-group elements: ruthenium, rhodium, or palladium, were suitable for an internal standard element to determine the 3d-transition metal elements, such as titanium, iron, and nickel, by measuring an appropriate pair of these absorption lines simultaneously. Several variances of the absorption signal, such as a variation in aspirated amounts of sample solution and a short-period drift of the primary light source, would be corrected and thus reduced, when the absorbance ratio of the analytical line to the internal standard line was measured. In Ti-Pd, Ni-Rh, and Fe-Ru systems chosen as typical test samples, the repeatability of the signal respnses was investigated with/without the internal standard method, resulting in better precision when the internal standard method was applied in the FAAS with a nitrous oxide-acetylene flame rather than an air-acetylene flame.
USDA Snack Policy Implementation: Best Practices From the Front Lines, United States, 2013-2014.
Asada, Yuka; Chriqui, Jamie; Chavez, Noel; Odoms-Young, Angela; Handler, Arden
2016-06-16
The Smart Snacks in Schools interim final rule was promulgated by the US Department of Agriculture (USDA) as authorized by the Healthy, Hunger-Free Kids Act of 2010 (PL 111-296) and implementation commenced beginning July 1, 2014; however, in the years leading up to this deadline, national studies suggested that most schools were far from meeting the USDA standards. Evidence to guide successful implementation of the standards is needed. This study examined snack policy implementation in exemplary high schools to learn best practices for implementation. Guided by a multiple case study approach, school professionals (n = 37) from 9 high schools across 8 states were recruited to be interviewed about perceptions of school snack implementation; schools were selected using criterion sampling on the basis of the HealthierUS Schools Challenge: Smarter Lunchrooms (HUSSC: SL) database. Interview transcripts and internal documents were organized and coded in ATLAS.Ti v7; 2 researchers coded and analyzed data using a constant comparative analysis method to identify best practice themes. Best practices for snack policy implementation included incorporating the HUSSC: SL award's comprehensive wellness approach; leveraging state laws or district policies to reinforce snack reform initiatives; creating strong internal and external partnerships; and crafting positive and strategic communications. Implementation of snack policies requires evidence of successful experiences from those on the front lines. As federal, state, and local technical assistance entities work to ensure implementation of the Smart Snacks standards, these best practices provide strategies to facilitate the process.
An Evaluation of Unit and ½ Mass Correction Approaches as a ...
Rare earth elements (REE) and certain alkaline earths can produce M+2 interferences in ICP-MS because they have sufficiently low second ionization energies. Four REEs (150Sm, 150Nd, 156Gd and 156Dy) produce false positives on 75As and 78Se and 132Ba can produce a false positive on 66Zn. Currently, US EPA Method 200.8 does not address these as sources of false positives. Additionally, these M+2 false positives are typically enhanced if collision cell technology is utilized to reduce polyatomic interferences associated with ICP-MS detection. A preliminary evaluation indicates that instrumental tuning conditions can impact the observed M+2/M+1 ratio and in turn the false positives generated on Zn, As and Se. Both unit and ½ mass approaches will be evaluated to correct for these false positives relative to the benchmark concentrations estimates from a triple quadrupole ICP-MS using standard solutions. The impact of matrix on these M+2 corrections will be evaluated over multiple analysis days with a focus on evaluating internal standards that mirror the matrix induced shifts in the M+2 ion transmission. The goal of this evaluation is to move away from fixed M+2 corrective approaches and move towards sample specific approaches that mimic the sample matrix induced variability while attempting to address intra-day variability of the M+2 correction factors through the use of internal standards. Oral Presentation via webinar for EPA Laboratory Technical Informati
Quality assurance in military medical research and medical radiation accident management.
Hotz, Mark E; Meineke, Viktor
2012-08-01
The provision of quality radiation-related medical diagnostic and therapeutic treatments cannot occur without the presence of robust quality assurance and standardization programs. Medical laboratory services are essential in patient treatment and must be able to meet the needs of all patients and the clinical personnel responsible for the medical care of these patients. Clinical personnel involved in patient care must embody the quality assurance process in daily work to ensure program sustainability. In conformance with the German Federal Government's concept for modern departmental research, the international standard ISO 9001, one of the relevant standards of the International Organization for Standardization (ISO), is applied in quality assurance in military medical research. By its holistic approach, this internationally accepted standard provides an excellent basis for establishing a modern quality management system in line with international standards. Furthermore, this standard can serve as a sound basis for the further development of an already established quality management system when additional standards shall apply, as for instance in reference laboratories or medical laboratories. Besides quality assurance, a military medical facility must manage additional risk events in the context of early recognition/detection of health risks of military personnel on deployment in order to be able to take appropriate preventive and protective measures; for instance, with medical radiation accident management. The international standard ISO 31000:2009 can serve as a guideline for establishing risk management. Clear organizational structures and defined work processes are required when individual laboratory units seek accreditation according to specific laboratory standards. Furthermore, international efforts to develop health laboratory standards must be reinforced that support sustainable quality assurance, as in the exchange and comparison of test results within the scope of external quality assurance, but also in the exchange of special diagnosis data among international research networks. In summary, the acknowledged standard for a quality management system to ensure quality assurance is the very generic standard ISO 9001.Health Phys. 103(2):221-225; 2012.
Assay of lovastatin containing dietary supplement by LC-MS/MS under MRM condition.
Di Donna, Leonardo; Bartella, Lucia; Napoli, Anna; Sindona, Giovanni; Mazzotti, Fabio
2018-05-16
Monacolin K, the active ingredient present in dietary supplement, is a nutraceutical whose health benefits have been widely documented. A fast approach for the assay of lovastatin in both form, lactone and acid, by mass spectrometry is presented. The quantitative assay is carried out by HPLC-MS/MS using the multiple reaction monitoring (MRM) mode and simvastatin and pravastatin as internal standards. The accuracy values ranged from 97 to 101%; the analytical parameters values of LOQ, LOD, recovery and reproducibility, were calculated analyzing fortified samples, confirming the reliability of the proposed approach. This article is protected by copyright. All rights reserved.
Kastritis, Efstathios; Terpos, Evangelos; Roussou, Maria; Gavriatopoulou, Maria; Migkou, Magdalini; Eleutherakis-Papaiakovou, Evangelos; Fotiou, Despoina; Ziogas, Dimitrios; Panagiotidis, Ioannis; Kafantari, Eftychia; Giannouli, Stavroula; Zomas, Athanasios; Konstantopoulos, Konstantinos; Dimopoulos, Meletios A.
2017-01-01
The Revised International Staging System (R-ISS) was recently introduced in order to improve risk stratification over that provided by the widely used standard International Staging System. In addition to the parameters of the standard system, the R-ISS incorporates the presence of chromosomal abnormalities detected by interphase fluorescence in situ hybridization [t(4;14), t(14;16) and del17p] and elevated serum lactate dehydrogenase. The R-ISS was formulated on the basis of a large dataset of selected patients who had participated in clinical trials and has not been validated in an independent cohort of unselected patients. Thus, we evaluated the R-ISS in 475 consecutive, unselected patients, treated in a single center. Our patients were older and more often had severe renal dysfunction than those in the original publication on the R-ISS. As regards distribution by group, 18% had R-ISS-1, 64.5% R-ISS-2 and 18% R-ISS-3. According to R-ISS group, the 5-year survival rate was 77%, 53% and 19% for R-ISS-1, -2 and -3, respectively (P<0.001). The R-ISS could identify three groups with distinct outcomes among patients treated with or without autologous stem cell transplantation, among those treated with either bortezomib-based or immunomodulatory drug-based primary therapy and in patients ≤65, 66–75 or >75 years. However, in patients with severe renal dysfunction the distinction between groups was less clear. In conclusion, our data in consecutive, unselected patients, with differences in the characteristics and treatment approaches compared to the original International Myeloma Working Group cohort, verified that R-ISS is a robust tool for risk stratification of newly diagnosed patients with symptomatic myeloma. PMID:27789676
International aerospace standards - An overview
NASA Astrophysics Data System (ADS)
Mason, J. L.
1983-10-01
Factors to be considered in adopting and extending international standards in the U.S. aerospace industry are reviewed. Cost-related advantages and disadvantages of standardization are weighed, and further obstacles are identified in the English/metric rivalry and the pacing of metrification. The problem of standard duplication is examined, and the issue of revenues from the sale of copyrighted documents describing standards is addressed. It is recommended that international metric-system standards be introduced, with proper timing, wherever possible, and that prompt negotiations be undertaken to prevent or resolve document-sales disagreements. The continuation of English-system standards for safety-related cockpit readouts and communications systems is suggested.
Design of the iSTAR International STudy on Astronomy Reasoning
NASA Astrophysics Data System (ADS)
Tatge, Coty B.; Slater, Stephanie J.
2015-01-01
Beginning in 2013, a small international collaborative of discipline-based astronomy education researchers began to build the foundation to start the International STudy on Astronomy Reasoning Project, known simply as iSTAR. The project was a direct result of the inability of existing large international investigations into the learning of science, such as the TIMSS and PISA studies, to provide actionable intelligence on either strengths or weaknesses of astronomy teaching across the world. This is not because those studies were flawed; rather, they focused on the general characteristics of teaching and learning across all sciences. Prior to the iSTAR effort, there has been no systematic effort to measure individual's conceptual astronomy understanding across the globe. The goal of studying a widely dispersed international sample is to identify cultural subpopulations that do not conform to our existing knowledge of student misconceptions, highlighting unexpected cultural or educational practices that hint at alternative, and perhaps more effective, means of instruction. As a first step, we are carefully translating the Test Of Astronomy STandards - TOAST multiple-choice assessment instrument and carefully attending to nuances that occur during the translation process as cultural clues to differences in the teaching and learning of astronomy. We are actively welcoming and seeking international partners in this work through the CAPERteam.com website and at https://www.surveymonkey.com/s/iSTAR-Registration . This project is sponsored and managed by the CAPER Center for Astronomy & Physics Education Research in collaboration with members of the International Astronomical Union-Commission 46.
26 CFR 1.23-4 - Performance and quality standards. [Reserved
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 1 2010-04-01 2010-04-01 true Performance and quality standards. [Reserved] 1.23-4 Section 1.23-4 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY INCOME TAX INCOME TAXES Changes in Rates During A Taxable Year § 1.23-4 Performance and quality standards. [Reserved...
What States Should Know about International Standards in Science: Highlights from Achieve's Analysis
ERIC Educational Resources Information Center
Achieve, Inc., 2010
2010-01-01
Achieve, through support from the Noyce Foundation, examined ten sets of international standards with the intent of informing the development of both the conceptual framework and Next Generation Science Standards. Achieve selected countries based on their strong performance on international assessments and/or their economic, political, or cultural…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-23
... National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines... March 3, 2010, final national emission standards for hazardous air pollutants for reciprocating internal... engines to allow emergency engines to operate for up to 15 hours per year as part of an emergency demand...
Both US Environmental Protection Agency (EPA) SW-846 Methods 8260C/5035 and 8261A include mixing soil with water and addition of internal standards prior to analyses but the equilibration of internal standards with the soil is not required. With increasing total organic carbon (...
ERIC Educational Resources Information Center
Sugahara, Satoshi; Wilson, Rachel
2013-01-01
The development and implementation of the International Education Standards (IES) for professional accountants is currently an important issue in accounting education and for educators interested in a shift toward international education standards more broadly. The purpose of this study is to investigate professional and research discourse…
Quality of tuberculosis care in India: a systematic review.
Satyanarayana, S; Subbaraman, R; Shete, P; Gore, G; Das, J; Cattamanchi, A; Mayer, K; Menzies, D; Harries, A D; Hopewell, P; Pai, M
2015-07-01
While Indian studies have assessed care providers' knowledge and practices, there is no systematic review on the quality of tuberculosis (TB) care. We searched multiple sources to identify studies (2000-2014) on providers' knowledge and practices. We used the International Standards for TB Care to benchmark quality of care. Of the 47 studies included, 35 were questionnaire surveys and 12 used chart abstraction. None assessed actual practice using standardised patients. Heterogeneity in the findings precluded meta-analysis. Of 22 studies evaluating provider knowledge about using sputum smears for diagnosis, 10 found that less than half of providers had correct knowledge; 3 of 4 studies assessing self-reported practices by providers found that less than a quarter reported ordering smears for patients with chest symptoms. In 11 of 14 studies that assessed treatment, less than one third of providers knew the standard regimen for drug-susceptible TB. Adherence to standards in practice was generally lower than correct knowledge of those standards. Eleven studies with both public and private providers found higher levels of appropriate knowledge/practice in the public sector. Available evidence suggests suboptimal quality of TB care, particularly in the private sector. Improvement of quality of care should be a priority for India.
Goddard, Braden; Croft, Stephen; Lousteau, Angela; ...
2016-05-25
Safeguarding nuclear material is an important and challenging task for the international community. One particular safeguards technique commonly used for uranium assay is active neutron correlation counting. This technique involves irradiating unused uranium with ( α,n) neutrons from an Am-Li source and recording the resultant neutron pulse signal which includes induced fission neutrons. Although this non-destructive technique is widely employed in safeguards applications, the neutron energy spectra from an Am-Li sources is not well known. Several measurements over the past few decades have been made to characterize this spectrum; however, little work has been done comparing the measured spectra ofmore » various Am-Li sources to each other. This paper examines fourteen different Am-Li spectra, focusing on how these spectra affect simulated neutron multiplicity results using the code Monte Carlo N-Particle eXtended (MCNPX). Two measurement and simulation campaigns were completed using Active Well Coincidence Counter (AWCC) detectors and uranium standards of varying enrichment. The results of this work indicate that for standard AWCC measurements, the fourteen Am-Li spectra produce similar doubles and triples count rates. Finally, the singles count rates varied by as much as 20% between the different spectra, although they are usually not used in quantitative analysis.« less
Code of Federal Regulations, 2010 CFR
2010-10-01
... and Service Contract Act-Price Adjustment (Multiple Year and Option Contracts). 52.222-43 Section 52... Standards Act and Service Contract Act—Price Adjustment (Multiple Year and Option Contracts). As prescribed...—Price Adjustment (Multiple Year and Option Contracts) (SEP 2009) (a) This clause applies to both...
Easy access to geophysical data sets at the IRIS Data Management Center
NASA Astrophysics Data System (ADS)
Trabant, C.; Ahern, T.; Suleiman, Y.; Karstens, R.; Weertman, B.
2012-04-01
At the IRIS Data Management Center (DMC) we primarily manage seismological data but also have other geophysical data sets for related fields including atmospheric pressure and gravity measurements and higher level data products derived from raw data. With a few exceptions all data managed by the IRIS DMC are openly available and we serve an international research audience. These data are available via a number of different mechanisms from batch requests submitted through email, web interfaces, near real time streams and more recently web services. Our initial suite of web services offer access to almost all of the raw data and associated metadata managed at the DMC. In addition, we offer services that apply processing to the data before it is sent to the user. Web service technologies are ubiquitous with support available in nearly every programming language and operating system. By their nature web services are programmatic interfaces, but by choosing a simple subset of web service methods we make our data available to a very broad user base. These interfaces will be usable by professional developers as well as non-programmers. Whenever possible we chose open and recognized standards. The data returned to the user is in a variety of formats depending on type, including FDSN SEED, QuakeML, StationXML, ASCII, PNG images and in some cases where no appropriate standard could be found a customized XML format. To promote easy access to seismological data for all researchers we are coordinating with international partners to define web service interfaces standards. Additionally we are working with key partners in Europe to complete the initial implementation of these services. Once a standard has been adopted and implemented at multiple data centers researchers will be able to use the same request tools to access data across multiple data centers. The web services that apply on-demand processing to requested data include the capability to apply instrument corrections and format translations which ultimately allows more researchers to use the data without knowledge of specific data and metadata formats. In addition to serving as a new platform on top of which research scientists will build advanced processing tools we anticipate that they will result in more data being accessible by more users.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-11
... apply to: prototypes (new designs) submitted after January 1, 2012; production testing of designs... Lifesaving Equipment: Production Testing and Harmonization With International Standards AGENCY: Coast Guard... and Standards Directorate, Office of Design and Engineering Standards, Lifesaving and Fire Safety...
This rule will adopt the current voluntary NOx and CO emissions standards of the United Nations International Civil Aviation Organization (ICAO), bringing the United States aircraft standards into alignment with the international standards.
Gardemann, Joachim; Wilp, Thomas
2016-05-01
In recent refugee migration into Germany the responsibilities and reactions of health authorities are still lacking general co-ordination. Can the ethical and technical standards of international humanitarian assistance serve as an appropriate and even a compulsory guideline for relief agencies, public health and regulatory authorities in Germany? Documents from the field of medical ethics, medical law, international humanitarian law and disaster medicine will be examined and checked for practicability by consulting experiences during the 1990s Balkan wars refugee movement and international missions of relief agencies. Ethical and technical standards of international humanitarian assistance have been developed, improved and evaluated for 20 years, and are valuable tools for emergency management. Victims of disaster or conflict have a right to live in dignity and therefore have a right to receive health care according to international standards. International ethical and technical standards for refugees should be considered in the Federal Republic of Germany like in any other country.
Harnessing Multiple Internal Reflections to Design Highly Absorptive Acoustic Metasurfaces
NASA Astrophysics Data System (ADS)
Shen, Chen; Cummer, Steven A.
2018-05-01
The rapid development of metasurfaces has enabled numerous intriguing applications with acoustically thin sheets. Here we report the theory and experimental realization of a nonresonant sound-absorbing strategy using metasurfaces by harnessing multiple internal reflections. We theoretically and numerically show that the higher-order diffraction of thin gradient-index metasurfaces is tied to multiple internal reflections inside the unit cells. Highly absorbing acoustic metasurfaces can be realized by enforcing multiple internal reflections together with a small amount of loss. A reflective gradient-index acoustic metasurface is designed based on the theory, and we further experimentally verify the performance using a three-dimensional printed prototype. Measurements show over 99% energy absorption at the peak frequency and a 95% energy absorption bandwidth of around 600 Hz. The proposed mechanism provides an alternative route for sound absorption without the necessity of high absorption of the individual unit cells.
Next Generation Space Surveillance System-of-Systems
NASA Astrophysics Data System (ADS)
McShane, B.
2014-09-01
International economic and military dependence on space assets is pervasive and ever-growing in an environment that is now congested, contested, and competitive. There are a number of natural and man-made risks that need to be monitored and characterized to protect and preserve the space environment and the assets within it. Unfortunately, today's space surveillance network (SSN) has gaps in coverage, is not resilient, and has a growing number of objects that get lost. Risks can be efficiently and effectively mitigated, gaps closed, resiliency improved, and performance increased within a next generation space surveillance network implemented as a system-of-systems with modern information architectures and analytic techniques. This also includes consideration for the newest SSN sensors (e.g. Space Fence) which are born Net-Centric out-of-the-box and able to seamlessly interface with the JSpOC Mission System, global information grid, and future unanticipated users. Significant opportunity exists to integrate legacy, traditional, and non-traditional sensors into a larger space system-of-systems (including command and control centers) for multiple clients through low cost sustainment, modification, and modernization efforts. Clients include operations centers (e.g. JSpOC, USSTRATCOM, CANSPOC), Intelligence centers (e.g. NASIC), space surveillance sensor sites (e.g. AMOS, GEODSS), international governments (e.g. Germany, UK), space agencies (e.g. NASA), and academic institutions. Each has differing priorities, networks, data needs, timeliness, security, accuracy requirements and formats. Enabling processes and technologies include: Standardized and type accredited methods for secure connections to multiple networks, machine-to-machine interfaces for near real-time data sharing and tip-and-queue activities, common data models for analytical processing across multiple radar and optical sensor types, an efficient way to automatically translate between differing client and sensor formats, data warehouse of time based space events, secure collaboration tools for international coalition space operations, shared concept-of-operations, tactics, techniques, and procedures.
ERIC Educational Resources Information Center
Ragan, Joseph M.; Savino, Christopher J.; Parashac, Paul; Hosler, Jonathan C.
2010-01-01
International Financial Reporting Standards now constitute an important part of educating young professional accountants. This paper looks at a case based process to teach International Financial Reporting Standards using integrated Enterprise Resource Planning software. The case contained within the paper can be used within a variety of courses…
26 CFR 1.430(f)-1 - Effect of prefunding balance and funding standard carryover balance.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 5 2011-04-01 2011-04-01 false Effect of prefunding balance and funding standard carryover balance. 1.430(f)-1 Section 1.430(f)-1 Internal Revenue INTERNAL REVENUE SERVICE... § 1.430(f)-1 Effect of prefunding balance and funding standard carryover balance. (a) In general—(1...
26 CFR 1.430(f)-1 - Effect of prefunding balance and funding standard carryover balance.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 5 2010-04-01 2010-04-01 false Effect of prefunding balance and funding standard carryover balance. 1.430(f)-1 Section 1.430(f)-1 Internal Revenue INTERNAL REVENUE SERVICE... Effect of prefunding balance and funding standard carryover balance. (a) In general—(1) Overview. This...
25 CFR 543.23 - What are the minimum internal control standards for audit and accounting?
Code of Federal Regulations, 2014 CFR
2014-04-01
... supervision, bingo cards, bingo card sales, draw, prize payout; cash and equivalent controls, technologic aids... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for audit... INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.23 What are the...
25 CFR 543.23 - What are the minimum internal control standards for audit and accounting?
Code of Federal Regulations, 2013 CFR
2013-04-01
... supervision, bingo cards, bingo card sales, draw, prize payout; cash and equivalent controls, technologic aids... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for audit... INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.23 What are the...
Cross-Cultural Validation of the Patient Perception of Integrated Care Survey.
Tietschert, Maike V; Angeli, Federica; van Raak, Arno J A; Ruwaard, Dirk; Singer, Sara J
2017-07-20
To test the cross-cultural validity of the U.S. Patient Perception of Integrated Care (PPIC) Survey in a Dutch sample using a standardized procedure. Primary data collected from patients of five primary care centers in the south of the Netherlands, through survey research from 2014 to 2015. Cross-sectional data collected from patients who saw multiple health care providers during 6 months preceding data collection. The PPIC survey includes 59 questions that measure patient perceived care integration across providers, settings, and time. Data analysis followed a standardized procedure guiding data preparation, psychometric analysis, and included invariance testing with the U.S. dataset. Latent scale structures of the Dutch and U.S. survey were highly comparable. Factor "Integration with specialist" had lower reliability scores and noninvariance. For the remaining factors, internal consistency and invariance estimates were strong. The standardized cross-cultural validation procedure produced strong support for comparable psychometric characteristics of the Dutch and U.S. surveys. Future research should examine the usability of the proposed procedure for contexts with greater cultural differences. © Health Research and Educational Trust.
Anderson, William J; Nowinska, Kamila; Hutter, Tanya; Mahajan, Sumeet; Fischlechner, Martin
2018-04-19
Surface-enhanced Raman spectroscopy (SERS) is well known for its high sensitivity that emerges due to the plasmonic enhancement of electric fields typically on gold and silver nanostructures. However, difficulties associated with the preparation of nanostructured substrates with uniform and reproducible features limit reliability and quantitation using SERS measurements. In this work we use layer-by-layer (LbL) self-assembly to incorporate multiple functional building blocks of collaborative assemblies of nanoparticles on colloidal spheres to fabricate SERS sensors. Gold nanoparticles (AuNPs) are packaged in discrete layers, effectively 'freezing nano-gaps', on spherical colloidal cores to achieve multifunctionality and reproducible sensing. Coupling between layers tunes the plasmon resonance for optimum SERS signal generation to achieve a 10 nM limit of detection. Significantly, using the layer-by-layer construction, SERS-active AuNP layers are spaced out and thus optically isolated. This uniquely allows the creation of an internal standard within each colloidal sensor to enable highly reproducible self-calibrated sensing. By using 4-mercaptobenzoic acid (4-MBA) as the internal standard adenine concentrations are quantified to an accuracy of 92.6-99.5%. Our versatile approach paves the way for rationally designed yet quantitative colloidal SERS sensors and their use in a variety of sensing applications.
Fountoulakis, Konstantinos N; Gonda, Xenia
2017-03-01
The current study investigated the relationship of suicide and homicide rates internationally. WHO database mortality data for 82 countries concerning suicide, homicides, and cancer and traffic accidents as controls were used. The analysis included Pearson correlation and multiple linear regression analysis. Worldwide homicidal rates explained 55.42%, 43.86% and 41.7% of male and 22.0%, 22.14% and 13.25% of female suicides for 2000, 2005 and 2010 respectively. In Europe there was a positive correlation between male suicide rates and all homicide rates including homicide rates in both genders, in male victims, and in female victims. In America there is no significant correlation. In Asia there is a significant correlation of male suicidal rates only with homicide rates of female victims. We observed marked and interesting differences in the pattern of association between Europe and the Americas. Overall the current paper suggests that at least in some human populations, suicidality and homicidality share common etiopathogenetic substrates and could be triggered by the same internal or external events or might develop based on common genetic background. Empirically it has been suggested that suicide is related to higher living standards while murder is related to poor quality of life and lower living standards. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Dubey, Sunil Kumar; Saha, R N; Jangala, Hemanth; Pasha, S
2013-12-01
A new ultra-performance liquid chromatography-electrospray ionization mass spectrometry (UPLC-MS/ESI) method for simultaneous determination of venlafaxine (VEN) and its metabolite O-desmethylvenlafaxine (ODV) in rat plasma has been developed and validated using Venlafaxine d6 as the internal standard. The compounds and internal standard were extracted from plasma by solid phase extraction. The UPLC separation of the analytes was performed on ACQUITY UPLC ® BEH Shield RP18 (1.7 µm, 100 mm×2.1 mm) column, using isocratic elution with mobile phase constituted of water (containing 2 mM ammonium acetate): acetonitrile (20:80, v/v) at a flow rate of 0.3 mL/min. All of the analytes were eluted within 1.5 min. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer, operating in multiple reaction monitoring (MRM) and positive ion mode. The precursor to product ion transitions monitored for VEN, ODV and Venlafaxine d6 were m / z 278.3→121.08, 264.2→107.1 and 284.4→121.0, respectively. The developed and validated method was used for the pharmacokinetic study of VEN in rats.
White Paper Summary of 2nd ASTM International Workshop on Hydrides in Zirconium Alloy Cladding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sindelar, R.; Louthan, M.; PNNL, B.
2015-05-29
This white paper recommends that ASTM International develop standards to address the potential impact of hydrides on the long term performance of irradiated zirconium alloys. The need for such standards was apparent during the 2nd ASTM International Workshop on Hydrides in Zirconium Alloy Cladding and Assembly Components, sponsored by ASTM International Committee C26.13 and held on June 10-12, 2014, in Jackson, Wyoming. The potentially adverse impacts of hydrogen and hydrides on the long term performance of irradiated zirconium-alloy cladding on used fuel were shown to depend on multiple factors such as alloy chemistry and processing, irradiation and post irradiation history,more » residual and applied stresses and stress states, and the service environment. These factors determine the hydrogen content and hydride morphology in the alloy, which, in turn, influence the response of the alloy to the thermo-mechanical conditions imposed (and anticipated) during storage, transport and disposal of used nuclear fuel. Workshop presentations and discussions showed that although hydrogen/hydride induced degradation of zirconium alloys may be of concern, the potential for occurrence and the extent of anticipated degradation vary throughout the nuclear industry because of the variations in hydrogen content, hydride morphology, alloy chemistry and irradiation conditions. The tools and techniques used to characterize hydrides and hydride morphologies and their impacts on material performance also vary. Such variations make site-to-site comparisons of test results and observations difficult. There is no consensus that a single material or system characteristic (e.g., reactor type, burnup, hydrogen content, end-of life stress, alloy type, drying temperature, etc.) is an effective predictor of material response during long term storage or of performance after long term storage. Multi-variable correlations made for one alloy may not represent the behavior of another alloy exposed to identical conditions and the material responses to thermo-mechanical exposures will be different depending on the materials and systems used. The discussions at the workshop showed several gaps in the standardization of processes and techniques necessary to assess the long term performance of irradiated zirconium alloy cladding during dry storage and transport. The development of, and adherence to, standards to help bridge these gaps will strengthen the technical basis for long term storage and post-storage operations, provide consistency across the nuclear industry, maximize the value of most observations, and enhance the understanding of behavioral differences among alloys. The need for, and potential benefits of, developing the recommended standards are illustrated in the various sections of this report.« less
Aung, Wint Yan; Massoumzadeh, Parinaz; Najmi, Safa; Salter, Amber; Heaps, Jodi; Benzinger, Tammie L S; Mar, Soe
2018-01-01
There are no clinical features or biomarkers that can reliably differentiate acute disseminated encephalomyelitis from multiple sclerosis at the first demyelination attack. Consequently, a final diagnosis is sometimes delayed by months and years of follow-up. Early treatment for multiple sclerosis is recommended to reduce long-term disability. Therefore, we intend to explore neuroimaging biomarkers that can reliably distinguish between the two diagnoses. We reviewed prospectively collected clinical, standard MRI and diffusion tensor imaging data from 12 pediatric patients who presented with acute demyelination with and without encephalopathy. Patients were followed for an average of 6.5 years to determine the accuracy of final diagnosis. Final diagnosis was determined using 2013 International Pediatric MS Study Group criteria. Control subjects consisted of four age-matched healthy individuals for each patient. The study population consisted of six patients with central nervous system demyelination with encephalopathy with a presumed diagnosis of acute disseminated encephalomyelitis and six without encephalopathy with a presumed diagnosis of multiple sclerosis or clinically isolated syndrome at high risk for multiple sclerosis. During follow-up, two patients with initial diagnosis of acute disseminated encephalomyelitis were later diagnosed with multiple sclerosis. Diffusion tensor imaging region of interest analysis of baseline scans showed differences between final diagnosis of multiple sclerosis and acute disseminated encephalomyelitis patients, whereby low fractional anisotropy and high radial diffusivity occurred in multiple sclerosis patients compared with acute disseminated encephalomyelitis patients and the age-matched controls. Fractional anisotropy and radial diffusivity measures may have the potential to serve as biomarkers for distinguishing acute disseminated encephalomyelitis from multiple sclerosis at the onset. Copyright © 2017 Elsevier Inc. All rights reserved.
IPDA PDS4 Project: Towards an International Planetary Data Standard
NASA Astrophysics Data System (ADS)
Martinez, Santa; Roatsch, Thomas; Capria, Maria Teresa; Heather, David; Yamamoto, Yukio; Hughes, Steven; Stein, Thomas; Cecconi, Baptiste; Prashar, Ajay; Batanov, Oleg; Gopala Krishna, Barla
2016-07-01
The International Planetary Data Alliance (IPDA) is an international collaboration of space agencies with the main objective of facilitating discovery, access and use of planetary data managed across international boundaries. For this purpose, the IPDA has adopted the NASA's Planetary Data System (PDS) standard as the de-facto archiving standard, and is working towards the internationalisation of the new generation of the standards, called PDS4. PDS4 is the largest upgrade in the history of the PDS, and is a significant step towards an online, distributed, model-driven and service-oriented architecture international archive. Following the successful deployment of PDS4 to support NASA's LADEE and MAVEN missions, PDS4 was endorsed by IPDA in 2014. This has led to the adoption of PDS4 by a number of international space agencies (ESA, JAXA, ISRO and Roscosmos, among others) for their upcoming missions. In order to closely follow the development of the PDS4 standards and to coordinate the international contribution and participation in its evolution, a group of experts from each international agency is dedicated to review different aspects of the standards and to capture recommendations and requirements to ensure the international needs are met. The activities performed by this group cover the assessment and implementation of all aspects of PDS4, including its use, documentation, tools, validation strategies and information model. This contribution will present the activities carried out by this group and how this partnership between PDS and IPDA provides an excellent foundation towards an international platform for planetary science research.
International standards for optical wireless communications: state-of-the-art and future directions
NASA Astrophysics Data System (ADS)
Marciniak, Marian
2017-10-01
As the number of active OWC installations is growing fast, the standards for compatibility of co-existing neighbouring systems are being developed. The paper addresses the Laser Safety (IEC standards), ITU-T Study Group 15 standards (G.640 Co-location longitudinally compatible interfaces for free space optical systems), ITU-Radiocommunication Sector standards (P.1817-1 Propagation data required for the design of terrestrial free-space optical links), and the IEEE Work in Progress - standardization activity on Visible Light Communications. International standards of FSO communications have been reviewed and discussed. ITU, IEC, and IEEE International standards for Free-Space Optical links have been reviewed. The system reliability and availability as well as security issues will be addressed as well in the talk.
[Differences and international standardization between acupuncture as therapy and as specialty].
Ng, Szetuen
2017-01-12
The purpose of this study is to explore the differences of definition and clinical roles as well as international standardization between acupuncture as therapy and as specialty, which can provide reference evidence for specialization and internationalization of acupuncture. Owing to the clinical efficacy and safety, the credibility and controversy both exist in acupuncture; moreover, there is a lack of fair definition and international precedent regarding acupuncture specialty. Therefore, it is particularly essential to objectively compare the differences of definitions and clinical roles as well as criteria of international standardization for acupuncture as therapy and as specialty. It is believed acupuncture standardization can draw lessons from the international medical standards, evidence-based medicine and acupuncture theory from the following three major projects:acupuncture safety and contraindications; acupuncture indications and treatment guidelines; acupuncture indication classified into 3 levels of evidence-based acupuncture disease spectrum, as objective evidence of indication of acupuncture specialty.
Calmet, D; Ameon, R; Bombard, A; Brun, S; Byrde, F; Chen, J; Duda, J-M; Forte, M; Fournier, M; Fronka, A; Haug, T; Herranz, M; Husain, A; Jerome, S; Jiranek, M; Judge, S; Kim, S B; Kwakman, P; Loyen, J; LLaurado, M; Michel, R; Porterfield, D; Ratsirahonana, A; Richards, A; Rovenska, K; Sanada, T; Schuler, C; Thomas, L; Tokonami, S; Tsapalov, A; Yamada, T
2017-04-01
Radiological protection is a matter of concern for members of the public and thus national authorities are more likely to trust the quality of radioactivity data provided by accredited laboratories using common standards. Normative approach based on international standards aims to ensure the accuracy or validity of the test result through calibrations and measurements traceable to the International System of Units. This approach guarantees that radioactivity test results on the same types of samples are comparable over time and space as well as between different testing laboratories. Today, testing laboratories involved in radioactivity measurement have a set of more than 150 international standards to help them perform their work. Most of them are published by the International Standardization Organization (ISO) and the International Electrotechnical Commission (IEC). This paper reviews the most essential ISO standards that give guidance to testing laboratories at different stages from sampling planning to the transmission of the test report to their customers, summarizes recent activities and achievements and present the perspectives on new standards under development by the ISO Working Groups dealing with radioactivity measurement in connection with radiological protection. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Loftus, Pete; Giudice, Seb
2014-08-01
Measurements underpin the engineering decisions that allow products to be designed, manufactured, operated, and maintained. Therefore, the quality of measured data needs to be systematically assured to allow decision makers to proceed with confidence. The use of standards is one way of achieving this. This paper explores the relevance of international documentary standards to the assessment of measurement system capability in High Value Manufacturing (HVM) Industry. An internal measurement standard is presented which supplements these standards and recommendations are made for a cohesive effort to develop the international standards to provide consistency in such industrial applications.
7 CFR 51.485 - Good internal quality.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Good internal quality. 51.485 Section 51.485... STANDARDS) United States Standards for Grades of Cantaloups 1 Definitions § 51.485 Good internal quality. Good internal quality means that the combined juice from the edible portion of a sample of cantaloups...
ERIC Educational Resources Information Center
Lee, Jaekyung; Liu, Xiaoyan; Amo, Laura Casey; Wang, Weichun Leilani
2014-01-01
Drawing on national and state assessment datasets in reading and math, this study tested "external" versus "internal" standards-based education models. The goal was to understand whether and how student performance standards work in multilayered school systems under No Child Left Behind Act of 2001 (NCLB). Under the…
ERIC Educational Resources Information Center
Colombani, Olivier; Langelier, Ophelie; Martwong, Ekkachai; Castignolles, Patrice
2011-01-01
The use of an internal standard is a conventional and convenient way to monitor the conversion of one or several monomers during a controlled radical polymerization. However, the validity of this technique relies on an accurate determination of the initial monomer-to-internal standard ratio, A[subscript 0], because all subsequent calculations of…
Code of Federal Regulations, 2010 CFR
2010-07-01
... emergency engines if I am a stationary CI internal combustion engine manufacturer? 60.4202 Section 60.4202... Combustion Engines Emission Standards for Manufacturers § 60.4202 What emission standards must I meet for emergency engines if I am a stationary CI internal combustion engine manufacturer? (a) Stationary CI...
The international standard for colistin*
Lightbown, J. W.; Bond, J. M.; Grab, B.
1973-01-01
An International Standard for Colistin has been established and the International Unit defined as the activity contained in 0.00004878 mg of this preparation. The unit was defined on the basis of a collaborative assay in which nine laboratories from six different countries participated. The material used to prepare the international standard had been manufactured in Japan; it was shown to have a composition similar to that of material produced in Europe and to be suitable for the assay of colistin from the existing sources of manufacture. PMID:4541149
NASA Astrophysics Data System (ADS)
Evans, David J.
2002-11-01
The documentary standards defining internationally adopted methodologies and protocols for calibrating transducers used to measure vibration are currently developed under the International Organization for Standardization (ISO) Technical Committee 108 Sub Committee 3 (Use and calibration of vibration and shock measuring instruments). Recent revisions of the documentary standards on primary methods for the calibration of accelerometers used to measure rectilinear motion have been completed. These standards can be, and have been, used as references in the technical protocols of key international and regional comparisons between National Measurement Institutes (NMIs) on the calibration of accelerometers. These key comparisons are occurring in part as a result of the creation of the Mutual Recognition Arrangement between NMIs which has appendices that document the uncertainties, and the comparisons completed in support of the uncertainties, claimed by the National Laboratories that are signatories of the MRA. The measurements for the first international and the first Interamerican System of Metrology (SIM) regional key comparisons in vibration have been completed. These intercomparisons were promulgated via the relatively new Consultative Committee for Acoustics, Ultrasound and Vibration (CCAUV) of the International Committee for Weights and Measures (CIPM) and SIM Metrology Working Group (MWG) 9, respectively.
Abbatiello, Susan E; Mani, D R; Keshishian, Hasmik; Carr, Steven A
2010-02-01
Multiple reaction monitoring mass spectrometry (MRM-MS) of peptides with stable isotope-labeled internal standards (SISs) is increasingly being used to develop quantitative assays for proteins in complex biological matrices. These assays can be highly precise and quantitative, but the frequent occurrence of interferences requires that MRM-MS data be manually reviewed, a time-intensive process subject to human error. We developed an algorithm that identifies inaccurate transition data based on the presence of interfering signal or inconsistent recovery among replicate samples. The algorithm objectively evaluates MRM-MS data with 2 orthogonal approaches. First, it compares the relative product ion intensities of the analyte peptide to those of the SIS peptide and uses a t-test to determine if they are significantly different. A CV is then calculated from the ratio of the analyte peak area to the SIS peak area from the sample replicates. The algorithm identified problematic transitions and achieved accuracies of 94%-100%, with a sensitivity and specificity of 83%-100% for correct identification of errant transitions. The algorithm was robust when challenged with multiple types of interferences and problematic transitions. This algorithm for automated detection of inaccurate and imprecise transitions (AuDIT) in MRM-MS data reduces the time required for manual and subjective inspection of data, improves the overall accuracy of data analysis, and is easily implemented into the standard data-analysis work flow. AuDIT currently works with results exported from MRM-MS data-processing software packages and may be implemented as an analysis tool within such software.
Abbatiello, Susan E.; Mani, D. R.; Keshishian, Hasmik; Carr, Steven A.
2010-01-01
BACKGROUND Multiple reaction monitoring mass spectrometry (MRM-MS) of peptides with stable isotope–labeled internal standards (SISs) is increasingly being used to develop quantitative assays for proteins in complex biological matrices. These assays can be highly precise and quantitative, but the frequent occurrence of interferences requires that MRM-MS data be manually reviewed, a time-intensive process subject to human error. We developed an algorithm that identifies inaccurate transition data based on the presence of interfering signal or inconsistent recovery among replicate samples. METHODS The algorithm objectively evaluates MRM-MS data with 2 orthogonal approaches. First, it compares the relative product ion intensities of the analyte peptide to those of the SIS peptide and uses a t-test to determine if they are significantly different. A CV is then calculated from the ratio of the analyte peak area to the SIS peak area from the sample replicates. RESULTS The algorithm identified problematic transitions and achieved accuracies of 94%–100%, with a sensitivity and specificity of 83%–100% for correct identification of errant transitions. The algorithm was robust when challenged with multiple types of interferences and problematic transitions. CONCLUSIONS This algorithm for automated detection of inaccurate and imprecise transitions (AuDIT) in MRM-MS data reduces the time required for manual and subjective inspection of data, improves the overall accuracy of data analysis, and is easily implemented into the standard data-analysis work flow. AuDIT currently works with results exported from MRM-MS data-processing software packages and may be implemented as an analysis tool within such software. PMID:20022980
Radin, Daniel P; Krebs, Austin; Maqsudlu, Arman; Patel, Parth
2018-01-01
Angiotensin-I-converting enzyme (ACE) inhibitors have been very effective in treating cardiac hypertension since their clinical inception over four decades ago. Since then, it has been established that angiotensin II, the product of ACE, has oncogenic and pro-proliferative qualities, which begs the question as to whether ACE inhibitors may have oncolytic characteristics. In fact, scattered reports suggest that ACE inhibitors are oncolytic and oncopreventive, but the available literature has yet to be thoroughly examined. In the present review, we examine the available literature and determine that ACE inhibitors would have great utility in the prevention and treatment of cancer. At the same time, they would augment the efficacy of chemo- and radiotherapy as well as mitigating damage to healthy tissue by standard chemotherapeutic regimens. We review some of the mounting clinical evidence and show that ACE inhibitors have oncolytic activity in multiple types of cancer and discuss the ability of ACE inhibitors to prevent cardiotoxicity of multiple chemotherapies. Our analysis demonstrates that the actions of ACE inhibitors converge on vascular endolthelial growth factor to reduce its levels in tumors and prevent construction of blood vessels to masses, leaving them nutrient-depleted and subsequently hindering their growth. Given that ACE inhibitors are approved by the Federal Drug Administration and the therapeutic dose for hypertension treatment also slows the growth of multiple cancers types, ACE inhibitors are in a perfect position to be repurposed as oncolytic agents, that would widely increase their utility in the clinic. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
USDA-ARS?s Scientific Manuscript database
The International Plant Protection Convention (IPPC) is an international plant health agreement, established in 1952, that aims to protect cultivated and wild plants by preventing the introduction and spread of pests. International Standards for Phytosanitary Measures (ISPMs) are the standards adopt...
77 FR 282 - Proposed Settlement Agreement
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-04
... revised the National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion... the stationary internal combustion engine new source performance standards (ICE NSPS) to allow owners and operators of emergency stationary internal combustion engines to operate emergency stationary...
Sizaret, P
1988-01-01
The main activities in international biological standardization during the 18 years that followed the first international biological standardization meeting in London in 1921 were concerned with expressing the potencies of test preparations in comparison with reference materials. After the Second World War, however, it became clear that the testing of biological substances against international reference materials was only one among several measures for obtaining safe and potent products. The activities in international biological standardization were therefore widened so that, by the strict observance of specific manufacturing and control requirements, it was possible to gain further in safety and efficacy. At the end of 1987, 42 international requirements for biological substances were available and were being used as national requirements, sometimes after minor modification, by the majority of WHO's Member States. This is of utmost importance for the worldwide use of safe and potent biological products, including vaccines.
Standards: The Keys to Domestic and International Competitiveness.
ERIC Educational Resources Information Center
Hunter, Robert D.
1993-01-01
Demonstrates the importance of standards for the competitiveness of U.S. companies and for international trade. The value of standards in research and development, marketing, design, purchasing, manufacturing, installation, and service is explained. Examples of specific standards and their application to the computer industry are included. (10…
EPA STANDARDS NETWORK FACT SHEET: ISO 14000: INTERNATIONAL ENVIRONMENTAL MANAGEMENT STANDARDS
This flyer provides an overview of the ISO 14000 series of International standards, supplying a brief history, structure of the Technical Committee (TC) 207, structure of the U.S. Technical Advisory Group (TAG) to ISO TC-207, status of the Standards development as of June 1997, w...
Oates, R P; Mcmanus, Michelle; Subbiah, Seenivasan; Klein, David M; Kobelski, Robert
2017-07-14
Internal standards are essential in electrospray ionization liquid chromatography-mass spectrometry (ESI-LC-MS) to correct for systematic error associated with ionization suppression and/or enhancement. A wide array of instrument setups and interfaces has created difficulty in comparing the quantitation of absolute analyte response across laboratories. This communication demonstrates the use of primary standards as operational qualification standards for LC-MS instruments and their comparison with commonly accepted internal standards. In monitoring the performance of internal standards for perfluorinated compounds, potassium hydrogen phthalate (KHP) presented lower inter-day variability in instrument response than a commonly accepted deuterated perfluorinated internal standard (d3-PFOS), with percent relative standard deviations less than or equal to 6%. The inter-day precision of KHP was greater than d3-PFOS over a 28-day monitoring of perfluorooctanesulfonic acid (PFOS), across concentrations ranging from 0 to 100μg/L. The primary standard trometamol (Trizma) performed as well as known internal standards simeton and tris (2-chloroisopropyl) phosphate (TCPP), with intra-day precision of Trizma response as low as 7% RSD on day 28. The inter-day precision of Trizma response was found to be greater than simeton and TCPP, across concentrations of neonicotinoids ranging from 1 to 100μg/L. This study explores the potential of primary standards to be incorporated into LC-MS/MS methodology to improve the quantitative accuracy in environmental contaminant analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Yu, Mu Xue; Jiang, Xiao Yun; Li, Yi Juan; Shen, Zhen Yu; Zhuang, Si Qi; Gu, Yu Fen
2018-02-01
The effect of using standardized parent training history-taking on the quality of medical records and communication skills among pediatric interns was determined. Fifth-year interns who were undertaking a pediatric clinical practice rotation were randomized to intervention and control groups. All of the pediatric interns received history-taking training by lecture and bedside teaching. The pediatric interns in the intervention group also received standardized parent history-taking training. The following two outcome measures were used: the scores of medical records, which were written by the pediatric interns after history-taking from real parents of pediatric patients; and the communication assessment tool (CAT) assessed by real parents. The general information, history of present illness (HPI), past medical history, personal history, family history, diagnosis, diagnostic analysis, and differential diagnosis scores in the intervention group were significantly higher than the control group (p < 0.05). Assessment of the CAT indicated that the real parents were more satisfied with the pediatric interns in the intervention group. Standardized parent training history-taking is effective in improving the quality of medical records by pediatric interns. Standardized parent training history-taking is a superior teaching tool for clinical reasoning ability, as well as communication skills in clinical pediatric practice.
Serbin, Lisa A; Kingdon, Danielle; Ruttle, Paula L; Stack, Dale M
2015-11-01
Most theoretical models of developmental psychopathology involve a transactional, bidirectional relation between parenting and children's behavior problems. The present study utilized a cross-lagged panel, multiple interval design to model change in bidirectional relations between child and parent behavior across successive developmental periods. Two major categories of child behavior problems, internalizing and externalizing, and two aspects of parenting, positive (use of support and structure) and harsh discipline (use of physical punishment), were modeled across three time points spaced 3 years apart. Two successive developmental intervals, from approximately age 7.5 to 10.5 and from 10.5 to 13.5, were included. Mother-child dyads (N = 138; 65 boys) from a lower income longitudinal sample of families participated, with standardized measures of mothers rating their own parenting behavior and teachers reporting on child's behavior. Results revealed different types of reciprocal relations between specific aspects of child and parent behavior, with internalizing problems predicting an increase in positive parenting over time, which subsequently led to a reduction in internalizing problems across the successive 3-year interval. In contrast, externalizing predicted reduced levels of positive parenting in a reciprocal sequence that extended across two successive intervals and predicted increased levels of externalizing over time. Implications for prevention and early intervention are discussed.
Review of codes, standards, and regulations for natural gas locomotives.
DOT National Transportation Integrated Search
2014-06-01
This report identified, collected, and summarized relevant international codes, standards, and regulations with potential : applicability to the use of natural gas as a locomotive fuel. Few international or country-specific codes, standards, and regu...
International Comparison Test in Asia-Pacific Region for Impulse Voltage Measurements
NASA Astrophysics Data System (ADS)
Wakimoto, Takayuki; Ishii, Masaru; Goshima, Hisashi; Hino, Etsuhiro; Shimizu, Hiroyuki; Li, Yi; Ik-Soo, Kim
The national standard class divider for the lightning impulse voltage measurements in Japan was developed in 1998. After three years, the standard impulse voltage calibrator was manufactured, too. These standard equipment are used as an industrial standard, and the performance had been evaluated annually supported by Ministry of Economy, Trade and Industry (METI). The standard impulse measuring system including the standard divider participated in the worldwide comparison test and its good performance was confirmed in 1999. Another international comparison test was carried out among three countries in the Asia-Pacific region in 2004 again and the standard measuring system participated in the test. In this paper, the details and the results of the international comparison tests in 2004 are described.
A review of the International Atomic Energy Agency (IAEA) international standards for tissue banks.
Morales Pedraza, Jorge; Lobo Gajiwala, Astrid; Martinez Pardo, María Esther
2012-03-01
The IAEA International Standards for Tissue Banks published in 2003 were based on the Standards then currently in use in the USA and the European Union, among others, and reflect the best practices associated with the operation of a tissue bank. They cover legal, ethical and regulatory controls as well as requirements and procedures from donor selection and tissue retrieval to processing and distribution of finished tissue for clinical use. The application of these standards allows tissue banks to operate with the current good tissue practice, thereby providing grafts of high quality that satisfy the national and international demand for safe and biologically useful grafts. The objective of this article is to review the IAEA Standards and recommend new topics that could improve the current version.
Jung, Jeeyoun; Park, Bongki; Lee, Ju Ah; You, Sooseong; Alraek, Terje; Bian, Zhao-Xiang; Birch, Stephen; Kim, Tae-Hun; Xu, Hao; Zaslawski, Chris; Kang, Byoung-Kab; Lee, Myeong Soo
2016-09-01
An international brainstorming session on standardizing pattern identification (PI) was held at the Korea Institute of Oriental Medicine on October 1, 2013 in Daejeon, South Korea. This brainstorming session was convened to gather insights from international traditional East Asian medicine specialists regarding PI standardization. With eight presentations and discussion sessions, the meeting allowed participants to discuss research methods and diagnostic systems used in traditional medicine for PI. One speaker presented a talk titled "The diagnostic criteria for blood stasis syndrome: implications for standardization of PI". Four speakers presented on future strategies and objective measurement tools that could be used in PI research. Later, participants shared information and methodology for accurate diagnosis and PI. They also discussed the necessity for standardizing PI and methods for international collaborations in pattern research.
International Safety Regulation and Standards for Space Travel and Commerce
NASA Astrophysics Data System (ADS)
Pelton, J. N.; Jakhu, R.
The evolution of air travel has led to the adoption of the 1944 Chicago Convention that created the International Civil Aviation Organization (ICAO), headquartered in Montreal, Canada, and the propagation of aviation safety standards. Today, ICAO standardizes and harmonizes commercial air safety worldwide. Space travel and space safety are still at an early stage of development, and the adoption of international space safety standards and regulation still remains largely at the national level. This paper explores the international treaties and conventions that govern space travel, applications and exploration today and analyzes current efforts to create space safety standards and regulations at the national, regional and global level. Recent efforts to create a commercial space travel industry and to license commercial space ports are foreseen as means to hasten a space safety regulatory process.
Hawboldt, John; Nash, Rose; FitzPatrick, Beverly
2017-03-06
International standards of pharmacy curricula are necessary to ensure student readiness for international placements. This paper explores whether curricula from two pharmacy programs, in Australia and Canada, are congruent with international standards and if students feel prepared for international placements. Nationally prescribed educational standards for the two schools were compared to each other and then against the International Pharmaceutical Federation (FIP) Global Competency Framework. Written student reflections complemented this analysis. Mapping results suggested substantial agreement between the FIP framework and Australia and Canada, with two gaps being identified. Moreover, the students felt their programs prepared them for their international placements. Despite differences in countries, pharmacy programs, and health-systems all students acclimatized to their new practice sites. Implications are that if pharmacy programs align well with FIP, pharmacists should be able to integrate and practise in other jurisdictions that also align with the FIP. This has implications for the mobility of pharmacy practitioners to countries not of their origin of training.
Code of Federal Regulations, 2013 CFR
2013-07-01
... I am an owner or operator of a stationary SI internal combustion engine? 60.4233 Section 60.4233... Combustion Engines Emission Standards for Owners and Operators § 60.4233 What emission standards must I meet if I am an owner or operator of a stationary SI internal combustion engine? (a) Owners and operators...
Code of Federal Regulations, 2010 CFR
2010-07-01
... I am an owner or operator of a stationary SI internal combustion engine? 60.4233 Section 60.4233... Combustion Engines Emission Standards for Owners and Operators § 60.4233 What emission standards must I meet if I am an owner or operator of a stationary SI internal combustion engine? (a) Owners and operators...
Code of Federal Regulations, 2012 CFR
2012-07-01
... I am an owner or operator of a stationary SI internal combustion engine? 60.4233 Section 60.4233... Combustion Engines Emission Standards for Owners and Operators § 60.4233 What emission standards must I meet if I am an owner or operator of a stationary SI internal combustion engine? (a) Owners and operators...
Code of Federal Regulations, 2014 CFR
2014-07-01
... I am an owner or operator of a stationary SI internal combustion engine? 60.4233 Section 60.4233... Combustion Engines Emission Standards for Owners and Operators § 60.4233 What emission standards must I meet if I am an owner or operator of a stationary SI internal combustion engine? (a) Owners and operators...
Code of Federal Regulations, 2011 CFR
2011-07-01
... I am an owner or operator of a stationary SI internal combustion engine? 60.4233 Section 60.4233... Combustion Engines Emission Standards for Owners and Operators § 60.4233 What emission standards must I meet if I am an owner or operator of a stationary SI internal combustion engine? (a) Owners and operators...
Yiin, James H; Anderson, Jeri L; Bertke, Stephen J; Tollerud, David J
2018-05-09
To examine dose-response relationships between internal uranium exposures and select outcomes among a cohort of uranium enrichment workers. Cox regression was conducted to examine associations between selected health outcomes and cumulative internal uranium with consideration for external ionizing radiation, work-related medical X-rays and contaminant radionuclides technetium ( 99 Tc) and plutonium ( 239 Pu) as potential confounders. Elevated and monotonically increasing mortality risks were observed for kidney cancer, chronic renal diseases, and multiple myeloma, and the association with internal uranium absorbed organ dose was statistically significant for multiple myeloma. Adjustment for potential confounders had minimal impact on the risk estimates. Kidney cancer, chronic renal disease, and multiple myeloma mortality risks were elevated with increasing internal uranium absorbed organ dose. The findings add to evidence of an association between internal exposure to uranium and cancer. Future investigation includes a study of cancer incidence in this cohort. © 2018 Wiley Periodicals, Inc.
Alpha-synuclein levels in patients with multiple system atrophy: a meta-analysis.
Yang, Fei; Li, Wan-Jun; Huang, Xu-Sheng
2018-05-01
This study evaluates the relationship between multiple system atrophy and α-synuclein levels in the cerebrospinal fluid, plasma and neural tissue. Literature search for relevant research articles was undertaken in electronic databases and study selection was based on a priori eligibility criteria. Random-effects meta-analyses of standardized mean differences in α-synuclein levels between multiple system atrophy patients and normal controls were conducted to obtain the overall and subgroup effect sizes. Meta-regression analyses were performed to evaluate the effect of age, gender and disease severity on standardized mean differences. Data were obtained from 11 studies involving 378 multiple system atrophy patients and 637 healthy controls (age: multiple system atrophy patients 64.14 [95% confidence interval 62.05, 66.23] years; controls 64.16 [60.06, 68.25] years; disease duration: 44.41 [26.44, 62.38] months). Cerebrospinal fluid α-synuclein levels were significantly lower in multiple system atrophy patients than in controls but in plasma and neural tissue, α-synuclein levels were significantly higher in multiple system atrophy patients (standardized mean difference: -0.99 [-1.65, -0.32]; p = 0.001). Percentage of male multiple system atrophy patients was significantly positively associated with the standardized mean differences of cerebrospinal fluid α-synuclein levels (p = 0.029) whereas the percentage of healthy males was not associated with the standardized mean differences of cerebrospinal fluid α-synuclein levels (p = 0.920). In multiple system atrophy patients, α-synuclein levels were significantly lower in the cerebrospinal fluid and were positively associated with the male gender.
Kahraman, Turhan; Özdoğar, Asiye Tuba; Honan, Cynthia Alison; Ertekin, Özge; Özakbaş, Serkan
2018-05-09
To linguistically and culturally adapt the Multiple Sclerosis Work Difficulties Questionnaire-23 (MSWDQ-23) for use in Turkey, and to examine its reliability and validity. Following standard forward-back translation of the MSWDQ-23, it was administered to 124 people with multiple sclerosis (MS). Validity was evaluated using related outcome measures including those related to employment status and expectations, disability level, fatigue, walking, and quality of life. Randomly selected participants were asked to complete the MSWDQ-23 again to assess test-retest reliability. Confirmatory factor analysis on the MSWDQ-23 demonstrated a good fit for the data, and the internal consistency of each subscale was excellent. The test-retest reliability for the total score, psychological/cognitive barriers, physical barriers, and external barriers subscales were high. The MSWDQ-23 and its subscales were positively correlated with the employment, disability level, walking, and fatigue outcome measures. This study suggests that the Turkish version of MSWDQ-23 has high reliability and adequate validity, and it can be used to determine the difficulties faced by people with multiple sclerosis in workplace. Moreover, the study provides evidence about the test-retest reliability of the questionnaire. Implications for rehabilitation Multiple sclerosis affects young people of working age. Understanding work-related problems is crucial to enhance people with multiple sclerosis likelihood of maintaining their job. The Multiple Sclerosis Work Difficulties Questionnaire-23 (MSWDQ-23) is a valid and reliable measure of perceived workplace difficulties in people with multiple sclerosis: we presented its validation to Turkish. Professionals working in the field of vocational rehabilitation may benefit from using the MSWDQ-23 to predict the current work outcomes and future employment expectations.
Olayo-Lortia, Jesús; Ferreira-Nuño, Armando; Velázquez-Moctezuma, Javier; Morales-Otal, Adriana
2014-10-01
The multiple partner choice arena (MPCA) is an experimental setup in which male rats display a significant shortening of ejaculation latency, which is the main characteristic of premature ejaculation (PE) in men. Thus, the MPCA is a potential animal model for PE. In this study, we further analyze whether the features of the MPCA satisfy the validity criteria for it to be considered an animal model as well as the possible participation of the serotoninergic system in the faster ejaculation exhibited by male rats in the MPCA. In Experiment 1, male rats were tested in a standard arena to assess their sexual behavior, then were assessed 1 week later in the MPCA. Another group was first tested in the MPCA, then in a standard arena. In Experiment 2, male rats divided into two groups were treated daily with WAY-100635 (5-HT(1A) antagonist) or vehicle for 15 days. In each group, half of the subjects were tested in a standard arena and half were tested in the MPCA on days 1, 8, and 15 of treatment. Number of intromissions and intromission and ejaculation latencies were the main outcome measures. In Experiment 1, males tested in the MPCA ejaculated significantly faster, regardless of the order in which they were evaluated in both arenas. In Experiment 2, the administration of WAY-100635 increased intromission and ejaculation latencies, and the number of intromissions in the MPCA. The results obtained in the MPCA support its use as an animal model for PE evaluation. © 2014 International Society for Sexual Medicine.
GKS. Minimal Graphical Kernel System C Binding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simons, R.W.
1985-10-01
GKS (the Graphical Kernel System) is both an American National Standard (ANS) and an ISO international standard graphics package. It conforms to ANS X3.124-1985 and to the May 1985 draft proposal for the GKS C Language Binding standard under development by the X3H3 Technical Committee. This implementation includes level ma (the lowest level of the ANS) and some routines from level mb. The following graphics capabilities are supported: two-dimensional lines, markers, text, and filled areas; control over color, line type, and character height and alignment; multiple simultaneous workstations and multiple transformations; and locator and choice input. Tektronix 4014 and 4115more » terminals are supported, and support for other devices may be added. Since this implementation was developed under UNIX, it uses makefiles, C shell scripts, the ar library maintainer, editor scripts, and other UNIX utilities. Therefore, implementing it under another operating system may require considerable effort. Also included with GKS is the small plot package (SPP), a direct descendant of the WEASEL plot package developed at Sandia. SPP is built on the GKS; therefore, all of the capabilities of GKS are available. It is not necessary to use GKS functions, since entire plots can be produced using only SPP functions, but the addition of GKS will give the programmer added power and flexibility. SPP provides single-call plot commands, linear and logarithmic axis commands, control for optional plotting of tick marks and tick mark labels, and permits plotting of data with or without markers and connecting lines.« less
Adams, Martin; Stamper, Paul D.; Dasgupta, Debanjana; Hewson, Roger; Buck, Charles D.; Richards, Allen L.; Hay, John
2016-01-01
Strategic laboratory planning in limited resource areas is essential for addressing global health security issues. Establishing a national reference laboratory, especially one with BSL-3 or -4 biocontainment facilities, requires a heavy investment of resources, a multisectoral approach, and commitments from multiple stakeholders. We make the case for donor organizations and recipient partners to develop a comprehensive laboratory operations roadmap that addresses factors such as mission and roles, engaging national and political support, securing financial support, defining stakeholder involvement, fostering partnerships, and building trust. Successful development occurred with projects in African countries and in Azerbaijan, where strong leadership and a clear management framework have been key to success. A clearly identified and agreed management framework facilitate identifying the responsibility for developing laboratory capabilities and support services, including biosafety and biosecurity, quality assurance, equipment maintenance, supply chain establishment, staff certification and training, retention of human resources, and sustainable operating revenue. These capabilities and support services pose rate-limiting yet necessary challenges. Laboratory capabilities depend on mission and role, as determined by all stakeholders, and demonstrate the need for relevant metrics to monitor the success of the laboratory, including support for internal and external audits. Our analysis concludes that alternative frameworks for success exist for developing and implementing capabilities at regional and national levels in limited resource areas. Thus, achieving a balance for standardizing practices between local procedures and accepted international standards is a prerequisite for integrating new facilities into a country's existing public health infrastructure and into the overall international scientific community. PMID:27559843
The Business Value of Superior Energy Performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKane, Aimee; Scheihing, Paul; Evans, Tracy
Industrial facilities participating in the U.S. Department of Energy’s (US DOE) Superior Energy Performance (SEP) program are finding that it provides them with significant business value. This value starts with the implementation of ISO 50001-Energy management system standard, which provides an internationally-relevant framework for integration of energy management into an organization’s business processes. The resulting structure emphasizes effective use of available data and supports continual improvement of energy performance. International relevance is particularly important for companies with a global presence or trading interests, providing them with access to supporting ISO standards and a growing body of certified companies representing themore » collective knowledge of communities of practice. This paper examines the business value of SEP, a voluntary program that builds on ISO 50001, inviting industry to demonstrate an even greater commitment through third-party verification of energy performance improvement to a specified level of achievement. Information from 28 facilities that have already achieved SEP certification will illustrate key findings concerning both the value and the challenges from SEP/ISO 50001 implementation. These include the facilities’ experience with implementation, internal and external value of third-party verification of energy performance improvement; attractive payback periods and the importance of SEP tools and guidance. US DOE is working to bring the program to scale, including the Enterprise-Wide Accelerator (SEP for multiple facilities in a company), the Ratepayer-Funded Program Accelerator (supporting tools for utilities and program administrators to include SEP in their program offerings), and expansion of the program to other sectors and industry supply chains.« less
Falcone, John L; Gonzalo, Jed D
2014-01-19
To determine Internal Medicine residency program compliance with the Accreditation Council for Graduate Medical Education 80% pass-rate standard and the correlation between residency program size and performance on the American Board of Internal Medicine Certifying Examination. Using a cross-sectional study design from 2010-2012 American Board of Internal Medicine Certifying Examination data of all Internal Medicine residency pro-grams, comparisons were made between program pass rates to the Accreditation Council for Graduate Medical Education pass-rate standard. To assess the correlation between program size and performance, a Spearman's rho was calculated. To evaluate program size and its relationship to the pass-rate standard, receiver operative characteristic curves were calculated. Of 372 Internal Medicine residency programs, 276 programs (74%) achieved a pass rate of =80%, surpassing the Accreditation Council for Graduate Medical Education minimum standard. A weak correlation was found between residency program size and pass rate for the three-year period (p=0.19, p<0.001). The area underneath the receiver operative characteristic curve was 0.69 (95% Confidence Interval [0.63-0.75]), suggesting programs with less than 12 examinees/year are less likely to meet the minimum Accreditation Council for Graduate Medical Education pass-rate standard (sensitivity 63.8%, specificity 60.4%, positive predictive value 82.2%, p<0.001). Although a majority of Internal Medicine residency programs complied with Accreditation Council for Graduate Medical Education pass-rate standards, a quarter of the programs failed to meet this requirement. Program size is positively but weakly associated with American Board of Internal Medicine Certifying Examination performance, suggesting other unidentified variables significantly contribute to program performance.
Analytical methods for determining fire resistance of timber members
Robert H. White
2008-01-01
The fire resistance ratings of wood members and assemblies, as of other materials, have traditionally been obtained by testing the assembly in a furnace in accordance with ASTM International (ASTM) Standard E119, International Organization for Standardization (ISO) Standard 834, and similar standards. These ratings are published in listings, such as Underwriters...
Interrogating Identity: The International Standard School in Indonesia
ERIC Educational Resources Information Center
Sakhiyya, Zulfa
2011-01-01
This paper examines the impact of the International Standard School (ISS) on the identity of Indonesia as a postcolonial nation. According to the Indonesian Ministry of National Education, an ISS is "a school which complies with the National Standard of Education and enriches its standards from the Organisation for Economic Cooperation and…
ERIC Educational Resources Information Center
Baird, Jo-Anne; Gray, Lena
2016-01-01
The ways in which examination standards are conceptualised and operationalised differently across nations has not been given sufficient attention. The international literature on standard-setting has been dominated by the psychometrics tradition. Broader conceptualisations of examination standards have been discussed in the literature in England,…
FRANK, ELLEN; RITCHEY, FIONA C.; LEVENSON, JESSICA C.
2015-01-01
We employed standard literature search techniques and surveyed participants on the International Society for Interpersonal Psychotherapy listserve (isipt-list@googlegroups.com) to catalogue the multiple and highly creative ways in which Klerman’s and Weissman’s original concept of interpersonal psychotherapy (IPT) has been modified to meet the needs of a vast range of patient populations. Focusing first on adaptations of the individual treatment model for subgroups of adult patients, we next describe further adaptations of four major off-shoots of IPT: interpersonal counseling (IPC), IPT for adolescents (IPT-A), group IPT (IPT-G) and most recently, brief IPT (IPT-B). We then discuss IPT “in-laws,” those treatments that have married IPT with of other forms of psychotherapy for patients with bipolar disorder, panic symptomatology, and substance abuse. We conclude with that although there have been myriad successful adaptations of IPT, there remain some conditions for which IPT adaptations have not been found to be efficacious. PMID:26453344
Sun, Bing; Tao, Lian; Zheng, Yun-Ling
2014-06-01
Human telomerase reverse transcriptase (hTERT) is an essential component required for telomerase activity and telomere maintenance. Several alternatively spliced forms of hTERT mRNA have been reported in human primary and tumor cells. Currently, however, there is no sensitive and accurate method for the simultaneous quantification of multiple alternatively spliced RNA transcripts, such as in the case of hTERT. Here we show droplet digital PCR (ddPCR) provides sensitive, simultaneous digital quantification in a single reaction of two alternatively spliced single deletion hTERT transcripts (α-/β+ and α+/β-) as well as the opportunity to manually quantify non-deletion (α+/β+) and double deletion (α-/β-) transcripts. Our ddPCR method enables direct comparison among four alternatively spliced mRNAs without the need for internal standards or multiple primer pairs specific for each variant as real-time PCR (qPCR) requires, thus eliminating potential variation due to differences in PCR amplification efficiency.
Celestial Reference Frames at Multiple Radio Wavelengths
NASA Technical Reports Server (NTRS)
Jacobs, Christopher S.
2012-01-01
In 1997 the IAU adopted the International Celestial Reference Frame (ICRF) built from S/X VLBI data. In response to IAU resolutions encouraging the extension of the ICRF to additional frequency bands, VLBI frames have been made at 24, 32, and 43 gigahertz. Meanwhile, the 8.4 gigahertz work has been greatly improved with the 2009 release of the ICRF-2. This paper discusses the motivations for extending the ICRF to these higher radio bands. Results to date will be summarized including evidence that the high frequency frames are rapidly approaching the accuracy of the 8.4 gigahertz ICRF-2. We discuss current limiting errors and prospects for the future accuracy of radio reference frames. We note that comparison of multiple radio frames is characterizing the frequency dependent systematic noise floor from extended source morphology and core shift. Finally, given Gaia's potential for high accuracy optical astrometry, we have simulated the precision of a radio-optical frame tie to be approximately10-15 microarcseconds ((1-sigma) (1-standard deviation), per component).
Cruza, Norberto Sotelo; Fierros, Luis E
2006-01-01
The present study was done at the internal medicine service oft he Hospital lnfantil in the State of Sonora, Mexico. We tried to address the question of the use of conceptual schemes and mind maps and its impact on the teaching-learning-evaluation process among medical residents. Analyze the effects of conceptual schemes, and mind maps as a teaching and evaluation tool and compare them with multiple choice exams among Pediatric residents. Twenty two residents (RI, RII, RIII)on service rotation during six months were assessed initially, followed by a lecture on a medical subject. Conceptual schemes and mind maps were then introduced as a teaching-learning-evaluation instrument. Comprehension impact and comparison with a standard multiple choice evaluation was done. The statistical package (JMP version 5, SAS inst. 2004) was used. We noted that when we used conceptual schemes and mind mapping, learning improvement was noticeable among the three groups of residents (P < 0.001) and constitutes a better evaluation tool when compared with multiple choice exams (P < 0.0005). Based on our experience we recommend the use of this educational technique for medical residents in training.
Internal curvature signal and noise in low- and high-level vision
Grabowecky, Marcia; Kim, Yee Joon; Suzuki, Satoru
2011-01-01
How does internal processing contribute to visual pattern perception? By modeling visual search performance, we estimated internal signal and noise relevant to perception of curvature, a basic feature important for encoding of three-dimensional surfaces and objects. We used isolated, sparse, crowded, and face contexts to determine how internal curvature signal and noise depended on image crowding, lateral feature interactions, and level of pattern processing. Observers reported the curvature of a briefly flashed segment, which was presented alone (without lateral interaction) or among multiple straight segments (with lateral interaction). Each segment was presented with no context (engaging low-to-intermediate-level curvature processing), embedded within a face context as the mouth (engaging high-level face processing), or embedded within an inverted-scrambled-face context as a control for crowding. Using a simple, biologically plausible model of curvature perception, we estimated internal curvature signal and noise as the mean and standard deviation, respectively, of the Gaussian-distributed population activity of local curvature-tuned channels that best simulated behavioral curvature responses. Internal noise was increased by crowding but not by face context (irrespective of lateral interactions), suggesting prevention of noise accumulation in high-level pattern processing. In contrast, internal curvature signal was unaffected by crowding but modulated by lateral interactions. Lateral interactions (with straight segments) increased curvature signal when no contextual elements were added, but equivalent interactions reduced curvature signal when each segment was presented within a face. These opposing effects of lateral interactions are consistent with the phenomena of local-feature contrast in low-level processing and global-feature averaging in high-level processing. PMID:21209356
Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum
Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.
The core role of the nurse practitioner: practice, professionalism and clinical leadership.
Carryer, Jenny; Gardner, Glenn; Dunn, Sandra; Gardner, Anne
2007-10-01
To draw on empirical evidence to illustrate the core role of nurse practitioners in Australia and New Zealand. Enacted legislation provides for mutual recognition of qualifications, including nursing, between New Zealand and Australia. As the nurse practitioner role is relatively new in both countries, there is no consistency in role expectation and hence mutual recognition has not yet been applied to nurse practitioners. A study jointly commissioned by both countries' Regulatory Boards developed information on the core role of the nurse practitioner, to develop shared competency and educational standards. Reporting on this study's process and outcomes provides insights that are relevant both locally and internationally. This interpretive study used multiple data sources, including published and grey literature, policy documents, nurse practitioner program curricula and interviews with 15 nurse practitioners from the two countries. Data were analysed according to the appropriate standard for each data type and included both deductive and inductive methods. The data were aggregated thematically according to patterns within and across the interview and material data. The core role of the nurse practitioner was identified as having three components: dynamic practice, professional efficacy and clinical leadership. Nurse practitioner practice is dynamic and involves the application of high level clinical knowledge and skills in a wide range of contexts. The nurse practitioner demonstrates professional efficacy, enhanced by an extended range of autonomy that includes legislated privileges. The nurse practitioner is a clinical leader with a readiness and an obligation to advocate for their client base and their profession at the systems level of health care. A clearly articulated and research informed description of the core role of the nurse practitioner provides the basis for development of educational and practice competency standards. These research findings provide new perspectives to inform the international debate about this extended level of nursing practice. The findings from this research have the potential to achieve a standardised approach and internationally consistent nomenclature for the nurse practitioner role.
NASA Astrophysics Data System (ADS)
Wang, Chao; Xiao, Jun; Luo, Xiaobing
2016-10-01
The neutron inelastic scattering cross section of 115In has been measured by the activation technique at neutron energies of 2.95, 3.94, and 5.24 MeV with the neutron capture cross sections of 197Au as an internal standard. The effects of multiple scattering and flux attenuation were corrected using the Monte Carlo code GEANT4. Based on the experimental values, the 115In neutron inelastic scattering cross sections data were theoretically calculated between the 1 and 15 MeV with the TALYS software code, the theoretical results of this study are in reasonable agreement with the available experimental results.
How can we maximize the diagnostic utility of uroflow?: ICI-RS 2017.
Gammie, Andrew; Rosier, Peter; Li, Rui; Harding, Chris
2018-01-09
To gauge the current level of diagnostic utility of uroflowmetry and to suggest areas needing research to improve this. A summary of the debate held at the 2017 meeting of the International Consultation on Incontinence Research Society, with subsequent analysis by the authors. Limited diagnostic sensitivity and specificity exist for maximum flow rates, multiple uroflow measurements, and flow-volume nomograms. There is a lack of clarity in flow rate curve shape description and uroflow time measurement. There is a need for research to combine uroflowmetry with other non-invasive indicators. Better standardizations of test technique, flow-volume nomograms, uroflow shape descriptions, and time measurements are required. © 2017 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Sachse, Karoline A.; Haag, Nicole
2017-01-01
Standard errors computed according to the operational practices of international large-scale assessment studies such as the Programme for International Student Assessment's (PISA) or the Trends in International Mathematics and Science Study (TIMSS) may be biased when cross-national differential item functioning (DIF) and item parameter drift are…
USDA Snack Policy Implementation: Best Practices From the Front Lines, United States, 2013–2014
Chriqui, Jamie; Chavez, Noel; Odoms-Young, Angela; Handler, Arden
2016-01-01
Introduction The Smart Snacks in Schools interim final rule was promulgated by the US Department of Agriculture (USDA) as authorized by the Healthy, Hunger-Free Kids Act of 2010 (PL 111–296) and implementation commenced beginning July 1, 2014; however, in the years leading up to this deadline, national studies suggested that most schools were far from meeting the USDA standards. Evidence to guide successful implementation of the standards is needed. This study examined snack policy implementation in exemplary high schools to learn best practices for implementation. Methods Guided by a multiple case study approach, school professionals (n = 37) from 9 high schools across 8 states were recruited to be interviewed about perceptions of school snack implementation; schools were selected using criterion sampling on the basis of the HealthierUS Schools Challenge: Smarter Lunchrooms (HUSSC: SL) database. Interview transcripts and internal documents were organized and coded in ATLAS.Ti v7; 2 researchers coded and analyzed data using a constant comparative analysis method to identify best practice themes. Results Best practices for snack policy implementation included incorporating the HUSSC: SL award’s comprehensive wellness approach; leveraging state laws or district policies to reinforce snack reform initiatives; creating strong internal and external partnerships; and crafting positive and strategic communications. Conclusion Implementation of snack policies requires evidence of successful experiences from those on the front lines. As federal, state, and local technical assistance entities work to ensure implementation of the Smart Snacks standards, these best practices provide strategies to facilitate the process. PMID:27309416
Chang, Kai-Chun; Chang, Yu-Ting; Tsai, Chin-En
2018-04-01
A liquid chromatography tandem mass spectrometric method was developed for the determination of two β-agonists (ractopamine and salbutamol) in pig hair samples. An isotope of ractopamine-d5 or salbutamol-d6 as an internal standard was used to carry out quantitative analysis. Concentrated sodium hydroxide was used to pretreat hair samples and then purified by the solid phase extraction (SPE) procedure. The extracted solution was evaporated and reconstituted for injection in the instrument with electrospray ionization (ESI) operating in a positive multiple-reaction-monitoring (MRM) mode. Ractopamine and salbutamol separation were performed on C18 analytical column under gradient condition. The internal standard calibration curve was linear in the range of concentration from 0.5 to 100 ng mL -1 (R 2 > 0.995). Recoveries of this method estimated at three spiked concentrations of 100, 250 and 500 ng mL -1 in pig hair samples, were 79-82% for ractopamine and 77-96% for salbutamol. The corresponding inter-day and intra-day precisions expressed as relative standard deviation (RSD %) were 3.8-6.4% and 3.8-8.6%, respectively. The analytical time for one sample was 8 min. The detection limit of this method was 0.6 and 8.3 ng mL -1 for ractopamine and salbutamol, respectively. This developed method can be applied for monitoring the use of the β-agonists salbutamol and ractopamine in swine feed incurred pig hair. Copyright © 2017. Published by Elsevier B.V.
Information Model Translation to Support a Wider Science Community
NASA Astrophysics Data System (ADS)
Hughes, John S.; Crichton, Daniel; Ritschel, Bernd; Hardman, Sean; Joyner, Ronald
2014-05-01
The Planetary Data System (PDS), NASA's long-term archive for solar system exploration data, has just released PDS4, a modernization of the PDS architecture, data standards, and technical infrastructure. This next generation system positions the PDS to meet the demands of the coming decade, including big data, international cooperation, distributed nodes, and multiple ways of analysing and interpreting data. It also addresses three fundamental project goals: providing more efficient data delivery by data providers to the PDS, enabling a stable, long-term usable planetary science data archive, and enabling services for the data consumer to find, access, and use the data they require in contemporary data formats. The PDS4 information architecture is used to describe all PDS data using a common model. Captured in an ontology modeling tool it supports a hierarchy of data dictionaries built to the ISO/IEC 11179 standard and is designed to increase flexibility, enable complex searches at the product level, and to promote interoperability that facilitates data sharing both nationally and internationally. A PDS4 information architecture design requirement stipulates that the content of the information model must be translatable to external data definition languages such as XML Schema, XMI/XML, and RDF/XML. To support the semantic Web standards we are now in the process of mapping the contents into RDF/XML to support SPARQL capable databases. We are also building a terminological ontology to support virtually unified data retrieval and access. This paper will provide an overview of the PDS4 information architecture focusing on its domain information model and how the translation and mapping are being accomplished.
Wang, Chunyan; Zhu, Hongbin; Zhang, Wenyan; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying
2013-02-01
The quantitative analysis of amino acids (AAs) in single dry blood spot (DBS) samples is an important issue for metabolic diseases as a second-tier test in newborn screening. An analytical method for quantifying underivatized AAs in DBS was developed by using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The sample preparation in this method is simple and ion-pairing agent is not used in the mobile phase that could avoid ion suppression, which happens in mass spectrometry and avoids damage to the column. Through chromatographic separation, some isomeric compounds could be identified and quantified, which cannot be solved through only appropriate multiple reactions monitoring transitions by MS/MS. The concentrations of the different AAs were determined using non-deuterated internal standard. All calibration curves showed excellent linearity within test ranges. For most of the amino acids the accuracy of extraction recovery was between 85.3 and 115 %, and the precision of relative standard deviation was <7.0 %. The 35 AAs could be identified in DBS specimens by the developed LC-MS/MS method in 17-19 min, and eventually 24 AAs in DBS were quantified. The results of the present study prove that this method as a second-tier test in newborn screening for metabolic diseases could be performed by the quantification of free AAs in DBS using the LC-MS/MS method. The assay has advantages of high sensitive, specific, and inexpensive merits because non-deuterated internal standard and acetic acid instead of ion-pairing agent in mobile phase are used in this protocol.
ERIC Educational Resources Information Center
Byrum, John D.
This paper describes two international standards for the representation of the names of languages. The first (ISO 639-1), published in 1988, provides two-letter codes for 136 languages and was produced primarily to meet terminological needs. The second (ISO 639-2) appeared in late 1998 and includes three-letter codes for 460 languages. This list…
In Situ Catalytic Groundwater Treatment Using Pd-Catalysts and Horizontal Flow Treatment Wells
2007-02-01
1,2,4-Trichlorobenzene Hexachlorobutadiene Naphthalene 1,2,3-Trichlorobenzene Internal Standards Fluorobenzene 2-Bromo- 1 - chloropropane a Retention...internal standard method using a purge-and-trap. Internal standards were: Fluorobenzene for PID, 2-Bromo- 1 - chloropropane for HECD. b Detector does not...information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and
Madhavaram, Hima; Woollard, Gerald A
2014-05-01
Urinary metanephrines are widely used in the diagnosis of catecholamine secreting tumours. Over the past two years we have been using the commercial Recipe(®) ClinRep(®) Complete Kit for Metanephrines in Urine coupled with high-performance liquid chromatography and coulometric detection. It was noticed that the internal standards on the patient chromatograms were sporadically raised due to interference. The interference had identical chromatographic and electrochemical properties to the Recipe(®) internal standard (undisclosed identity). Inspection of the patient names showed it seemingly had a higher frequency and magnitude in patients of Indian origin. The source of the interference was tracked by dietary observation and intervention to curry leaves, a common component of Indian foods. The interference was chromatographically and electrochemically indistinguishable from the internal standard. The mass spectrum of the pentafluoropropionate derivative of the interference matched the Recipe(®) internal standard and was identified as methoxyhydroxybenzylamine by library match. The component co-elutes exactly with internal standard and artifactually decreases the metanephrine and normetanephrine results. It is surprising that it has not been described previously. Patients being assessed for catecholamine secreting tumours should be advised to withdraw from eating Indian foods at least 24 h prior to commencement of urinary collection.
Improving quality of tuberculosis care in India.
Pai, Madhukar; Satyanarayana, Srinath; Hopewell, Phil
2014-01-01
In India, the quality of care that tuberculosis (TB) patients receive varies considerably and is often not in accordance with the national and international standards. In this article, we provide an overview of the third (latest) edition of the International Standards of Tuberculosis Care (ISTC). These standards are supported by the existing World Health Organization guidelines and policy statements pertaining to TB care and have been endorsed by a number of international organizations. We call upon all health care providers in the country to practice TB care that is consistent with these standards, as well as the upcoming Standards for TB Care in India (STCI).
77 FR 57524 - Stage 3 Helicopter Noise Certification Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-18
... standards of the International Civil Aviation Organization (ICAO). The proposal of these more stringent... Organization (ICAO) is the international body with the responsibility for the development of international..., organizations, and governmental jurisdictions subject to regulation.'' To achieve that principle, the RFA...
Mechanisms for the prevention of marine bioinvasions for better biosecurity.
Hewitt, Chad L; Campbell, Marnie L
2007-01-01
Biosecurity management allows countries to meet a number of international obligations and provides some protection from potential degradation of environmental, economic, social and cultural values. Ocean governance relies on the precepts of ecologically sustainable development to manage the multiple uses in the coastal zone. The increasing reliance on aquaculture to provide food security and economic development has led to an increase in the use of non-native target species grown as food sources. Increased economic activity has led to shifting trade patterns and increased efficiencies in vessels with the resulting increase in the number of introduced marine species via ballast water and hull fouling. Herein we review the different marine biosecurity strategies and legislation that have been implemented internationally and locally that aid in preventing and managing introduced marine species, with some attention to Australia and New Zealand as examples. Typical tools being used include quarantine, Import Health Standards, voluntary cleaning guidelines, and risk assessment, all of which aim to prevent introductions.
International employment in clinical practice: influencing factors for the dental hygienist.
Abbott, A; Barrow, S-Y; Lopresti, F; Hittelman, E
2005-02-01
To assess demographics, job characteristics, geographical regions, resources and commitment, which influence dental hygienists seeking international clinical practice employment opportunities. Questionnaires were mailed to a convenience sample of members of the Dental Hygienists' Association of the City of New York. Statistical analyses were conducted and frequency distributions and relationships between variables were calculated. Seventy-two percent of respondents reported that they are or may be interested in working overseas. Italy and Spain (67%) were the regions of most interest. Salary (65%) was cited as the most influencing factor in selection, whereas non-compliance with the equivalency to Occupational Safety and Health Administration standards (74%) was the most frequently perceived barrier. Multiple language fluency was statistically significant (0.003) regarding interest in overseas employment. Policy makers, employers and educators need to be aware of these findings should recruitment be a possibility to render urgently needed oral hygiene care in regions where there is a perceived shortage of dental hygienists.
Adjusting Inequality: Education and Structural Adjustment Policies in Tanzania
ERIC Educational Resources Information Center
Vavrus, Frances
2005-01-01
International economic forces increasingly affect policy at multiple levels and in multiple domains. The interplay of three levels--international, national, and local--are underresearched in the social and educational policy fields, which includes educational policy studies. In this article, Frances Vavrus employs ethnography to investigate how…
77 FR 9859 - Lifesaving Equipment: Production Testing and Harmonization With International Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-21
... inflatable buoyant apparatuses may be certified using either occupant weight standard. Likewise, equipment...-AB46 Lifesaving Equipment: Production Testing and Harmonization With International Standards AGENCY... lifesaving equipment to harmonize Coast Guard regulations for inflatable liferafts and inflatable buoyant...
PIAAC Technical Standards and Guidelines
ERIC Educational Resources Information Center
OECD Publishing, 2014
2014-01-01
The Programme for International Assessment of Adult Competencies (PIAAC) will establish technical standards and guidelines to ensure that the survey design and implementation processes of PIAAC yield high-quality and internationally comparable data. This document provides a revised version of the technical standards and guidelines originally…
40 CFR 437.47 - Pretreatment standards for new sources (PSNS).
Code of Federal Regulations, 2010 CFR
2010-07-01
... subparts A, B, or C of this part may be subject to Multiple Wastestream Subcategory pretreatment standards representing the application of PSNS set forth in paragraphs (b), (c), (d), or (e) of this section if the... Multiple Wastestream Subcategory standards set forth in paragraphs (b), (c), (d) or (e) of this section; (2...
40 CFR 437.46 - Pretreatment standards for existing sources (PSES)
Code of Federal Regulations, 2010 CFR
2010-07-01
... from subparts A, B, or C of this part may be subject to Multiple Wastestream Subcategory pretreatment standards representing the application of PSES set forth in paragraphs (b), (c), (d), or (e) of this section... applicable Multiple Wastestream Subcategory standards set forth in paragraphs (b), (c), (d) or (e) of this...
9 CFR 113.108 - Clostridium Novyi Bacterin-Toxoid.
Code of Federal Regulations, 2014 CFR
2014-01-01
... which reacts with Lo and L+ doses of Standard Toxin according to their definitions. (ii) Lo dose. The... 0.1 International Unit of antitoxin per ml. (ii) Make a dilution of Standard Toxin in which 0.1 Lo... Antitoxin with 0.1 Lo dose of diluted Standard Toxin and combine 0.1 International Unit of Standard...
9 CFR 113.108 - Clostridium Novyi Bacterin-Toxoid.
Code of Federal Regulations, 2013 CFR
2013-01-01
... which reacts with Lo and L+ doses of Standard Toxin according to their definitions. (ii) Lo dose. The... 0.1 International Unit of antitoxin per ml. (ii) Make a dilution of Standard Toxin in which 0.1 Lo... Antitoxin with 0.1 Lo dose of diluted Standard Toxin and combine 0.1 International Unit of Standard...
9 CFR 113.108 - Clostridium Novyi Bacterin-Toxoid.
Code of Federal Regulations, 2011 CFR
2011-01-01
... which reacts with Lo and L+ doses of Standard Toxin according to their definitions. (ii) Lo dose. The... 0.1 International Unit of antitoxin per ml. (ii) Make a dilution of Standard Toxin in which 0.1 Lo... Antitoxin with 0.1 Lo dose of diluted Standard Toxin and combine 0.1 International Unit of Standard...
9 CFR 113.108 - Clostridium Novyi Bacterin-Toxoid.
Code of Federal Regulations, 2012 CFR
2012-01-01
... which reacts with Lo and L+ doses of Standard Toxin according to their definitions. (ii) Lo dose. The... 0.1 International Unit of antitoxin per ml. (ii) Make a dilution of Standard Toxin in which 0.1 Lo... Antitoxin with 0.1 Lo dose of diluted Standard Toxin and combine 0.1 International Unit of Standard...
[International Standards of Tuberculosis Care (ISTC)--comments from the German point of view].
Castell, S; Bauer, T; Diel, R; Hedrich, A; Magdorf, K; Rüsch-Gerdes, S; Schaberg, T; Loddenkemper, R
2012-04-01
The "International Standards for Tuberculosis Care" (ISTC) were developed by the World Health Organisation (WHO) and others to provide internationally agreed and, if possible, evidence-based standards for tuberculosis care including the care by private providers who are not part of national tuberculosis programmes or health-care systems. Hence, the ISTC primarily address resource-restrained countries with high tuberculosis prevalence. In this article, the German translation of the 21 standards from 2009 is presented - addressing diagnostic and therapeutic standards, co-infection (especially with HIV) and public-health issues. The accompanying comments show how these standards have to be modified for Germany due to the medical resources available here and country-specific characteristics respectively. © Georg Thieme Verlag KG Stuttgart · New York.
Micro-mass standards to calibrate the sensitivity of mass comparators
NASA Astrophysics Data System (ADS)
Madec, Tanguy; Mann, Gaëlle; Meury, Paul-André; Rabault, Thierry
2007-10-01
In mass metrology, the standards currently used are calibrated by a chain of comparisons, performed using mass comparators, that extends ultimately from the international prototype (which is the definition of the unit of mass) to the standards in routine use. The differences measured in the course of these comparisons become smaller and smaller as the standards approach the definitions of their units, precisely because of how accurately they have been adjusted. One source of uncertainty in the determination of the difference of mass between the mass compared and the reference mass is the sensitivity error of the comparator used. Unfortunately, in the market there are no mass standards small enough (of the order of a few hundreds of micrograms) for a valid evaluation of this source of uncertainty. The users of these comparators therefore have no choice but to rely on the characteristics claimed by the makers of the comparators, or else to determine this sensitivity error at higher values (at least 1 mg) and interpolate from this result to smaller differences of mass. For this reason, the LNE decided to produce and calibrate micro-mass standards having nominal values between 100 µg and 900 µg. These standards were developed, then tested in multiple comparisons on an A5 type automatic comparator. They have since been qualified and calibrated in a weighing design, repeatedly and over an extended period of time, to establish their stability with respect to oxidation and the harmlessness of the handling and storage procedure associated with their use. Finally, the micro-standards so qualified were used to characterize the sensitivity errors of two of the LNE's mass comparators, including the one used to tie France's Platinum reference standard (Pt 35) to stainless steel and superalloy standards.
Active investigation of material damage under load using micro-CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Navalgund, Megha, E-mail: megha.navalgund@ge.com; Mishra, Debasish; Manoharan, V.
2015-03-31
Due the growth of composite materials across multiple industries such as Aviation, Wind there is an increasing need to not just standardize and improve manufacturing processes but also to design these materials for the specific applications. One of the things that this translates to is understanding how failure initiates and grows in these materials and at what loads, especially around internal flaws such as voids or features such as ply drops. Traditional methods of investigating internal damage such as CT lack the resolution to resolve ply level damage in composites. Interrupted testing with layer removal can be used to investigatemore » internal damage using microscopy; however this is a destructive method. Advanced techniques such as such as DIC are useful for in-situ damage detection, however are limited to surface information and would not enable interrogating the volume. Computed tomography has become a state of the art technique for metrology and complete volumetric investigation especially for metallic components. However, its application to the composite world is still nascent. This paper demonstrates micro-CT’s capability as a gauge to quantitatively estimate the extent of damage and understand the propagation of damage in PMC composites while the component is under stress.« less
Hippert, Christine
2002-12-01
Presently, globalization and the world economy maintain power relations that hamper the economic integrity and the political autonomy of the developing world. My paper addresses specific economic conditions that perpetuate poverty and poor health. I examine multinational corporations and their effects on women's health, particularly in Mexico and parts of Asia. The advent of multinational corporate business in Mexico, Malaysia, Philippines, India, and Indonesia has led to increased poverty and human rights abuses. Women bear the brunt of this because of specific international economic arrangements and their low social status, both locally and globally. As a result, their physical, mental, and emotional health is suffering. Solutions to these health problems have been proposed on multiple levels: international top-down approaches (i.e., employing international protectionist regulatory standards, exposing multinationals who infringe on their workers' human rights), as well as local grassroots organizational campaigns (i.e., conducting informational human rights workshops for factory workers). Ultimately, the answers lie in holding corporations accountable to their laborers while developing countries maintain their comparative advantage; this is the only way women's health will improve and the developing world can entice corporate investment.
Mawson, Deborah H; Jeffrey, Keon L; Teale, Philip; Grace, Philip B
2018-06-19
A rapid, accurate and robust method for the determination of catechin (C), epicatechin (EC), gallocatechin (GC), epigallocatechin (EGC), catechin gallate (Cg), epicatechin gallate (ECg), gallocatechin gallate (GCg) and epigallocatechin gallate (EGCg) concentrations in human plasma has been developed. The method utilises protein precipitation following enzyme hydrolysis, with chromatographic separation and detection using reversed-phase liquid chromatography - tandem mass spectrometry (LC-MS/MS). Traditional issues such as lengthy chromatographic run times, sample and extract stability, and lack of suitable internal standards have been addressed. The method has been evaluated using a comprehensive validation procedure, confirming linearity over appropriate concentration ranges, and inter/intra batch precision and accuracies within suitable thresholds (precisions within 13.8% and accuracies within 12.4%). Recoveries of analytes were found to be consistent between different matrix samples, compensated for using suitable internal markers and within the performance of the instrumentation used. Similarly, chromatographic interferences have been corrected using the internal markers selected. Stability of all analytes in matrix is demonstrated over 32 days and throughout extraction conditions. This method is suitable for high throughput sample analysis studies. This article is protected by copyright. All rights reserved.
Active investigation of material damage under load using micro-CT
NASA Astrophysics Data System (ADS)
Navalgund, Megha; Zunjarrao, Suraj; Mishra, Debasish; Manoharan, V.
2015-03-01
Due the growth of composite materials across multiple industries such as Aviation, Wind there is an increasing need to not just standardize and improve manufacturing processes but also to design these materials for the specific applications. One of the things that this translates to is understanding how failure initiates and grows in these materials and at what loads, especially around internal flaws such as voids or features such as ply drops. Traditional methods of investigating internal damage such as CT lack the resolution to resolve ply level damage in composites. Interrupted testing with layer removal can be used to investigate internal damage using microscopy; however this is a destructive method. Advanced techniques such as such as DIC are useful for in-situ damage detection, however are limited to surface information and would not enable interrogating the volume. Computed tomography has become a state of the art technique for metrology and complete volumetric investigation especially for metallic components. However, its application to the composite world is still nascent. This paper demonstrates micro-CT's capability as a gauge to quantitatively estimate the extent of damage & understand the propagation of damage in PMC composites while the component is under stress.
Community-Wide Zero Energy Ready Home Standard
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herk, A.; Beggs, T.
This report outlines the steps a developer can use when looking to create and implement higher performance standards such as the U.S. Department of Energy (DOE) Zero Energy Ready Home (ZERH) standards in a community. The report also describes the specific examples of how this process was followed by a developer, Forest City, in the Stapleton community in Denver, Colorado. IBACOS described the steps used to begin to bring the DOE ZERH standard to the Forest City Stapleton community based on 15 years of community-scale development work done by IBACOS. As a result of this prior IBACOS work, the teammore » gained an understanding of the various components that a master developer needs to consider and created strategies for incorporating those components in the initial phases of development to achieve higher performance buildings in the community. An automated scoring system can be used to perform an internal audit that provides a detailed and consistent evaluation of how several homes under construction or builders' floor plans compare with the requirements of the DOE Zero Energy Ready Home program. This audit can be performed multiple times at specific milestones during construction to allow the builder to make changes as needed throughout construction for the project to meet Zero Energy Ready Home standards. This scoring system also can be used to analyze a builder's current construction practices and design.« less
International Standardization of Library and Documentation Techniques.
ERIC Educational Resources Information Center
International Federation for Documentation, The Hague (Netherlands).
This comparative study of the national and international standards, rules and regulations on library and documentation techniques adopted in various countries was conducted as a preliminary step in determining the minimal bases for facilitating national and international cooperation between documentalists and librarians. The study compares and…
46 CFR 199.03 - Relationship to international standards.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Relationship to international standards. 199.03 Section 199.03 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LIFESAVING APPLIANCES AND ARRANGEMENTS LIFESAVING SYSTEMS FOR CERTAIN INSPECTED VESSELS General § 199.03 Relationship to international...
Quality of tuberculosis care in India: a systematic review
Satyanarayana, S.; Subbaraman, R.; Shete, P.; Gore, G.; Das, J.; Cattamanchi, A.; Mayer, K.; Menzies, D.; Harries, A. D.; Hopewell, P.; Pai, M.
2015-01-01
SUMMARY BACKGROUND While Indian studies have assessed care providers’ knowledge and practices, there is no systematic review on the quality of tuberculosis (TB) care. METHODS We searched multiple sources to identify studies (2000–2014) on providers’ knowledge and practices. We used the International Standards for TB Care to benchmark quality of care. RESULTS Of the 47 studies included, 35 were questionnaire surveys and 12 used chart abstraction. None assessed actual practice using standardised patients. Heterogeneity in the findings precluded meta-analysis. Of 22 studies evaluating provider knowledge about using sputum smears for diagnosis, 10 found that less than half of providers had correct knowledge; 3 of 4 studies assessing self-reported practices by providers found that less than a quarter reported ordering smears for patients with chest symptoms. In 11 of 14 studies that assessed treatment, less than one third of providers knew the standard regimen for drug-susceptible TB. Adherence to standards in practice was generally lower than correct knowledge of those standards. Eleven studies with both public and private providers found higher levels of appropriate knowledge/practice in the public sector. CONCLUSIONS Available evidence suggests suboptimal quality of TB care, particularly in the private sector. Improvement of quality of care should be a priority for India. PMID:26056098
Mouratidou, T; Miguel, M L; Androutsos, O; Manios, Y; De Bourdeaudhuij, I; Cardon, G; Kulaga, Z; Socha, P; Galcheva, S; Iotova, V; Payr, A; Koletzko, B; Moreno, L A
2014-08-01
The ToyBox-intervention is a kindergarten-based, family-involved intervention targeting multiple lifestyle behaviours in preschool children, their teachers and their families. This intervention was conducted in six European countries, namely Belgium, Bulgaria, Germany, Greece, Poland and Spain. The aim of this paper is to provide a descriptive overview of the harmonization and standardization procedures of the baseline and follow-up evaluation of the study (and substudies). Steps related to the study's operational, standardization and harmonization procedures as well as the impact and outcome evaluation assessment tools used are presented. Experiences from the project highlight the importance of safeguarding the measurement process to minimize data heterogeneity derived from potential measurement error and country-by-country differences. In addition, it was made clear that continuing quality control and support is an important component of such studies. For this reason, well-supported communication channels, such as regular email updates and teleconferences, and regular internal and external meetings to ensure smooth and accurate implementation were in place during the study. The ToyBox-intervention and its harmonized and standardized procedures can serve as a successful case study for future studies evaluating the efficacy of similar interventions. © 2014 World Obesity.
Science and the rules governing anti-doping violations.
Bowers, Larry D
2010-01-01
The fight against the use of performance-enhancing drugs in sports has been in effect for nearly 90 years. The formation of the World Anti-Doping Agency in 1999 was a major event because an independent agency was entrusted with harmonization of the antidoping program. In addition to sports governing bodies, governments have endorsed WADA and its programs by signing a United Nations Education, Science, and Cultural Organization Convention on Doping. The first step in the harmonization process was the development of the World Anti-Doping Program. This program consisted of five documents - the Code, the International Standard for Testing, the International Standard for Laboratories, the Prohibited List, and the International Standard for Therapeutic Use Exemptions - which unified the approach of the international federations and national antidoping agencies in applying antidoping rules. For laboratory testing, the International Standard for Laboratories establishes the performance expectations for and competence of laboratories recognized by WADA, including accreditation under ISO/IEC 17025. The antidoping rules are adjudicated by arbitration using the internationally recognized Court of Arbitration for Sport.
Whole lung morphometry with 3D multiple b-value hyperpolarized gas MRI and compressed sensing.
Chan, Ho-Fung; Stewart, Neil J; Parra-Robles, Juan; Collier, Guilhem J; Wild, Jim M
2017-05-01
To demonstrate three-dimensional (3D) multiple b-value diffusion-weighted (DW) MRI of hyperpolarized 3 He gas for whole lung morphometry with compressed sensing (CS). A fully-sampled, two b-value, 3D hyperpolarized 3 He DW-MRI dataset was acquired from the lungs of a healthy volunteer and retrospectively undersampled in the k y and k z phase-encoding directions for CS simulations. Optimal k-space undersampling patterns were determined by minimizing the mean absolute error between reconstructed and fully-sampled 3 He apparent diffusion coefficient (ADC) maps. Prospective three-fold, undersampled, 3D multiple b-value 3 He DW-MRI datasets were acquired from five healthy volunteers and one chronic obstructive pulmonary disease (COPD) patient, and the mean values of maps of ADC and mean alveolar dimension (Lm D ) were validated against two-dimensional (2D) and 3D fully-sampled 3 He DW-MRI experiments. Reconstructed undersampled datasets showed no visual artifacts and good preservation of the main image features and quantitative information. A good agreement between fully-sampled and prospective undersampled datasets was found, with a mean difference of +3.4% and +5.1% observed in mean global ADC and Lm D values, respectively. These differences were within the standard deviation range and consistent with values reported from healthy and COPD lungs. Accelerated CS acquisition has facilitated 3D multiple b-value 3 He DW-MRI scans in a single breath-hold, enabling whole lung morphometry mapping. Magn Reson Med 77:1916-1925, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
Sudore, Rebecca L.; Stewart, Anita L.; Knight, Sara J.; McMahan, Ryan D.; Feuz, Mariko; Miao, Yinghui; Barnes, Deborah E.
2013-01-01
Introduction Advance directives have traditionally been considered the gold standard for advance care planning. However, recent evidence suggests that advance care planning involves a series of multiple discrete behaviors for which people are in varying stages of behavior change. The goal of our study was to develop and validate a survey to measure the full advance care planning process. Methods The Advance Care Planning Engagement Survey assesses “Process Measures” of factors known from Behavior Change Theory to affect behavior (knowledge, contemplation, self-efficacy, and readiness, using 5-point Likert scales) and “Action Measures” (yes/no) of multiple behaviors related to surrogate decision makers, values and quality of life, flexibility for surrogate decision making, and informed decision making. We administered surveys at baseline and 1 week later to 50 diverse, older adults from San Francisco hospitals. Internal consistency reliability of Process Measures was assessed using Cronbach's alpha (only continuous variables) and test-retest reliability of Process and Action Measures was examined using intraclass correlations. For discriminant validity, we compared Process and Action Measure scores between this cohort and 20 healthy college students (mean age 23.2 years, SD 2.7). Results Mean age was 69.3 (SD 10.5) and 42% were non-White. The survey took a mean of 21.4 minutes (±6.2) to administer. The survey had good internal consistency (Process Measures Cronbach's alpha, 0.94) and test-retest reliability (Process Measures intraclass correlation, 0.70; Action Measures, 0.87). Both Process and Action Measure scores were higher in the older than younger group, p<.001. Conclusion A new Advance Care Planning Engagement Survey that measures behavior change (knowledge, contemplation, self-efficacy, and readiness) and multiple advance care planning actions demonstrates good reliability and validity. Further research is needed to assess whether survey scores improve in response to advance care planning interventions and whether scores are associated with receipt of care consistent with one's wishes. PMID:24039772
Kim, Ki-Hyun; Anthwal, A; Pandey, Sudhir Kumar; Kabir, Ehsanul; Sohn, Jong Ryeul
2010-11-01
In this study, a series of GC calibration experiments were conducted to examine the feasibility of the thermal desorption approach for the quantification of five carbonyl compounds (acetaldehyde, propionaldehyde, butyraldehyde, isovaleraldehyde, and valeraldehyde) in conjunction with two internal standard compounds. The gaseous working standards of carbonyls were calibrated with the aid of thermal desorption as a function of standard concentration and of loading volume. The detection properties were then compared against two types of external calibration data sets derived by fixed standard volume and fixed standard concentration approach. According to this comparison, the fixed standard volume-based calibration of carbonyls should be more sensitive and reliable than its fixed standard concentration counterpart. Moreover, the use of internal standard can improve the analytical reliability of aromatics and some carbonyls to a considerable extent. Our preliminary test on real samples, however, indicates that the performance of internal calibration, when tested using samples of varying dilution ranges, can be moderately different from that derivable from standard gases. It thus suggests that the reliability of calibration approaches should be examined carefully with the considerations on the interactive relationships between the compound-specific properties and the operation conditions of the instrumental setups.
Nsimba, Stephen E D
2008-12-01
To review the global implications associated with the use of substandard and or counterfeit drugs in developing and may be developed countries. The focus of this review is particularly on antiretroviral (ARVs), antimalarials and other drugs. Review of various literatures through Pub-Med, Medline, Google and Internet search to retrieve and download published materials was done by the author of this review paper. When patients receive a counterfeit medicines, they are subjected to multiple risks. They often suffer more than just an inconvenience; as they become victims of fraud medicines and are all put at risk of adverse effects from unprescribed medicines or substandard ingredients. Additionally, patients may lose confidence in health care professionals including their physician and pharmacist, and potentially modern medicine or the pharmaceutical industry in general. Counterfeit or substandard (poor quality) drugs pose threats to society; not only to the individual in terms of the health side effects experienced, but also to the public in terms of trade relations, economic implications, and the effects on global pandemics. It is vital for suppliers, providers, and patients to be aware of current trends in counterfeiting in order to best prepare for encounters with suspicious products. Furthermore, this is an issue that needs to be continually dealt with on national and international policy levels. Developing countries should try their level best to establish good laboratories for monitoring and checking quality of all pharmaceuticals manufactured locally and those imported or donated to these countries. The Ministries of Health and all stakeholders involved in this issue must ensure that all drugs meet the set or established international standards and national standards. Failure to do so will be to misuse the hard earned forex that is normally borrowed from banks for the procurement and distribution of drugs to its people. Indeed sub-standard medications do more harm than good to people's health and it is unethical to give such drugs to people. Of course, in any market, some corruption and fraud always exist, but there are few commercial markets where fraud can have such drastic impact on global health and welfare. It is essential, therefore, that a multi-faceted approach be used to control this problem which affects the international community and continuously threatens the health of millions of people especially in developing countries. Developing countries should try their best at all costs establish good laboratories for monitoring or checking for quality control for all pharmaceuticals locally manufactured and those imported (entering) or donated to countries to make sure that they meet the set or established international or national standards. Short of that countries will be wasting a lot of money using forex which has been borrowed in a form a loans procuring and distributing to its people sub-standard medications which will do more harm than good to its indigenous people and this is unethical per se to give people drugs not meeting required set international standards.
77 FR 37397 - Proposed Settlement Agreement
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-21
... Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines (the RICE NESHAP... revised the National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion...
Code of Federal Regulations, 2011 CFR
2011-07-01
... I am an owner or operator of a stationary internal combustion engine using special fuels? 60.4217... Compression Ignition Internal Combustion Engines Special Requirements § 60.4217 What emission standards must I meet if I am an owner or operator of a stationary internal combustion engine using special fuels? (a...
Code of Federal Regulations, 2013 CFR
2013-07-01
... I am an owner or operator of a stationary internal combustion engine using special fuels? 60.4217... Compression Ignition Internal Combustion Engines Special Requirements § 60.4217 What emission standards must I meet if I am an owner or operator of a stationary internal combustion engine using special fuels...
Code of Federal Regulations, 2014 CFR
2014-07-01
... I am an owner or operator of a stationary internal combustion engine using special fuels? 60.4217... Compression Ignition Internal Combustion Engines Special Requirements § 60.4217 What emission standards must I meet if I am an owner or operator of a stationary internal combustion engine using special fuels...
Code of Federal Regulations, 2010 CFR
2010-07-01
... I am an owner or operator of a stationary internal combustion engine using special fuels? 60.4217... Compression Ignition Internal Combustion Engines Special Requirements § 60.4217 What emission standards must I meet if I am an owner or operator of a stationary internal combustion engine using special fuels? (a...
Code of Federal Regulations, 2012 CFR
2012-07-01
... I am an owner or operator of a stationary internal combustion engine using special fuels? 60.4217... Compression Ignition Internal Combustion Engines Special Requirements § 60.4217 What emission standards must I meet if I am an owner or operator of a stationary internal combustion engine using special fuels...
[Accreditation of clinical laboratories based on ISO standards].
Kawai, Tadashi
2004-11-01
International Organization for Standardization (ISO) have published two international standards (IS) to be used for accreditation of clinical laboratories; ISO/IEC 17025:1999 and ISO 15189:2003. Any laboratory accreditation body must satisfy the requirements stated in ISO/IEC Guide 58. In order to maintain the quality of the laboratory accreditation bodies worldwide, the International Laboratory Accreditation Cooperation (ILAC) has established the mutual recognition arrangement (MRA). In Japan, the International Accreditation Japan (IAJapan) and the Japan Accreditation Board for Conformity Assessment (JAB) are the members of the ILAC/MRA group. In 2003, the Japanese Committee for Clinical Laboratory Standards (JCCLS) and the JAB have established the Development Committee of Clinical Laboratory Accreditation Program (CLAP), in order to establish the CLAP, probably starting in 2005.
Savel'eva, N B; Bykovskaia, N Iu; Dikunets, M A; Bolotov, S L; Rodchenkov, G M
2010-01-01
The objective of this study was to demonstrate the possibility to use deuterated compounds as internal standards for the quantitative analysis of morphine by gas chromatography with mass-selective detection for the purpose of doping control. The paper is focused on the problems associated with the use of deuterated morphine-D3 as the internal standard. Quantitative characteristics of the calibration dependence thus documented are presented along with uncertainty values obtained in the measurements with the use of deuterated morphine-D6. An approach to the assessment of method bias associated with the application of morphine-D6 as the deuterated internal standard is described.
Adibi, Mehrad; Pearle, Margaret S; Lotan, Yair
2012-07-01
Multiple studies have shown an increase in the hospital admission rates due to infectious complications after transrectal ultrasonography (TRUS)-guided prostate biopsy (TRUSBx), mostly related to a rise in the prevalence of fluoroquinolone-resistant organisms. As a result, multiple series have advocated the use of more intensive prophylactic antibiotic regimens to augment the effect of the widely used fluoroquinolone prophylaxis for TRUSBx. The present study compares the cost-effectiveness fluoroquinolone prophylaxis to more intensive prophylactic antibiotic regimens, which is an important consideration for any antibiotic regimen used on a wide-scale for TRUSBx prophylaxis. To compare the cost-effectiveness of fluoroquinolones vs intensive antibiotic regimens for transrectal ultrasonography (TRUS)-guided prostate biopsy (TRUSBx) prophylaxis. Risk of hospital admission for infectious complications after TRUSBx was determined from published data. The average cost of hospital admission due to post-biopsy infection was determined from patients admitted to our University hospital ≤1 week of TRUSBx. A decision tree analysis was created to compare cost-effectiveness of standard vs intensive antibiotic prophylactic regimens based on varying risk of infection, cost, and effectiveness of the intensive antibiotic regimen. Baseline assumption included cost of TRUSBx ($559), admission rate (1%), average cost of admission ($5900) and cost of standard and intensive antibiotic regimens of $1 and $33, respectively. Assuming a 50% risk reduction in admission rates with intensive antibiotics, the standard regimen was slightly less costly with average cost of $619 vs $622, but was associated with twice as many infections. Sensitivity analyses found that a 1.1% risk of admission for quinolone-resistant infections or a 54% risk reduction attributed to the more intensive antibiotic regimen will result in cost-equivalence for the two regimens. Three-way sensitivity analyses showed that small increases in probability of admission using the standard antibiotics or greater risk reduction using the intensive regimen result in the intensive prophylactic regimen becoming substantially more cost-effectiveness even at higher costs. As the risk of admission for infectious complications due to TRUSBx increases, use of an intensive prophylactic antibiotic regimen becomes significantly more cost-effective than current standard antibiotic prophylaxis. © 2011 BJU INTERNATIONAL.
Prior, Sandra; Hufton, Simon E; Fox, Bernard; Dougall, Thomas; Rigsby, Peter; Bristow, Adrian
2018-01-01
The intrinsic complexity and heterogeneity of therapeutic monoclonal antibodies is built into the biosimilarity paradigm where critical quality attributes are controlled in exhaustive comparability studies with the reference medicinal product. The long-term success of biosimilars will depend on reassuring healthcare professionals and patients of consistent product quality, safety and efficacy. With this aim, the World Health Organization has endorsed the need for public bioactivity standards for therapeutic monoclonal antibodies in support of current controls. We have developed a candidate international potency standard for rituximab that was evaluated in a multi-center collaborative study using participants' own qualified Fc-effector function and cell-based binding bioassays. Dose-response curve model parameters were shown to reflect similar behavior amongst rituximab preparations, albeit with some differences in potency. In the absence of a common reference standard, potency estimates were in poor agreement amongst laboratories, but the use of the candidate preparation significantly reduced this variability. Our results suggest that the candidate rituximab standard can support bioassay performance and improve data harmonization, which when implemented will promote consistency of rituximab products over their life-cycles. This data provides the first scientific evidence that a classical standardization exercise allowing traceability of bioassay data to an international standard is also applicable to rituximab. However, we submit that this new type of international standard needs to be used appropriately and its role not to be mistaken with that of the reference medicinal product.
Towards a Policy Framework for Decent Work.
ERIC Educational Resources Information Center
Egger, Philippe
2002-01-01
International Labour Organization (ILO) standards for decent work promote social justice and humane working conditions. These standards can contribute to sustainable development, macroeconomic security, and fairer distribution of benefits from growth. The ILO is working for policy integration and promotion of international labor standards as a…
A Serviced-based Approach to Connect Seismological Infrastructures: Current Efforts at the IRIS DMC
NASA Astrophysics Data System (ADS)
Ahern, Tim; Trabant, Chad
2014-05-01
As part of the COOPEUS initiative to build infrastructure that connects European and US research infrastructures, IRIS has advocated for the development of Federated services based upon internationally recognized standards using web services. By deploying International Federation of Digital Seismograph Networks (FDSN) endorsed web services at multiple data centers in the US and Europe, we have shown that integration within seismological domain can be realized. By deploying identical methods to invoke the web services at multiple centers this approach can significantly ease the methods through which a scientist can access seismic data (time series, metadata, and earthquake catalogs) from distributed federated centers. IRIS has developed an IRIS federator that helps a user identify where seismic data from global seismic networks can be accessed. The web services based federator can build the appropriate URLs and return them to client software running on the scientists own computer. These URLs are then used to directly pull data from the distributed center in a very peer-based fashion. IRIS is also involved in deploying web services across horizontal domains. As part of the US National Science Foundation's (NSF) EarthCube effort, an IRIS led EarthCube Building Block's project is underway. When completed this project will aid in the discovery, access, and usability of data across multiple geoscienece domains. This presentation will summarize current IRIS efforts in building vertical integration infrastructure within seismology working closely with 5 centers in Europe and 2 centers in the US, as well as how we are taking first steps toward horizontal integration of data from 14 different domains in the US, in Europe, and around the world.
Timmons, Chris; Trees, Eija; Ribot, Efrain M; Gerner-Smidt, Peter; LaFon, Patti; Im, Sung; Ma, Li Maria
2016-06-01
Non-O157 Shiga toxin-producing Escherichia coli (STEC) are foodborne pathogens of growing concern worldwide that have been associated with several recent multistate and multinational outbreaks of foodborne illness. Rapid and sensitive molecular-based bacterial strain discrimination methods are critical for timely outbreak identification and contaminated food source traceback. One such method, multiple-locus variable-number tandem repeat analysis (MLVA), is being used with increasing frequency in foodborne illness outbreak investigations to augment the current gold standard bacterial subtyping technique, pulsed-field gel electrophoresis (PFGE). The objective of this study was to develop a MLVA assay for intra- and inter-serogroup discrimination of six major non-O157 STEC serogroups-O26, O111, O103, O121, O45, and O145-and perform a preliminary internal validation of the method on a limited number of clinical isolates. The resultant MLVA scheme consists of ten variable number tandem repeat (VNTR) loci amplified in three multiplex PCR reactions. Sixty-five unique MLVA types were obtained among 84 clinical non-O157 STEC strains comprised of geographically diverse sporadic and outbreak related isolates. Compared to PFGE, the developed MLVA scheme allowed similar discrimination among serogroups O26, O111, O103, and O121 but not among O145 and O45. To more fully compare the discriminatory power of this preliminary MLVA method to PFGE and to determine its epidemiological congruence, a thorough internal and external validation needs to be performed on a carefully selected large panel of strains, including multiple isolates from single outbreaks. Copyright © 2016. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Pine, Jerome; Aschbacher, Pamela; Roth, Ellen; Jones, Melanie; McPhee, Cameron; Martin, Catherine; Phelps, Scott; Kyle, Tara; Foley, Brian
2006-05-01
A large number of American elementary school students are now studying science using the hands-on inquiry curricula developed in the 1990s: Insights; Full Option Science System (FOSS); and Science and Technology for Children (STC). A goal of these programs, echoed in the National Science Education Standards, is that children should gain abilities to do scientific inquiry and understanding about scientific inquiry. We have studied the degree to which students can do inquiries by using four hands-on performance assessments, which required one or three class periods. To be fair, the assessments avoided content that is studied in depth in the hands-on programs. For a sample of about 1000 fifth grade students, we compared the performance of students in hands-on curricula with an equal number of students with textbook curricula. The students were from 41 classrooms in nine school districts. The results show little or no curricular effect. There was a strong dependence on students' cognitive ability, as measured with a standard multiple-choice instrument. There was no significant difference between boys and girls. Also, there was no difference on a multiple-choice test, which used items released from the Trends in International Mathematics and Science Study (TIMSS). It is not completely clear whether the lack of difference on the performance assessments was a consequence of the assessments, the curricula, and/or the teaching.
Galati, Eunice A. B.; Galvis-Ovallos, Fredy; Lawyer, Phillip; Léger, Nicole; Depaquit, Jérôme
2017-01-01
Phlebotomine (Diptera, Psychodidae, Phlebotominae) taxonomy has been studied extensively, primarily due to the role of these flies as vectors of various parasites, including species of Leishmania, Bartonella and arboviruses that cause diseases in humans and other vertebrates. We present some topics discussed at a round-table on phlebotomine taxonomy held at the Ninth International Symposium on Phlebotomine Sandflies (ISOPS IX) in Reims, France, in June 2016. To date, approximately one thousand phlebotomine species have been described worldwide, although in varying languages and mostly without standardization of characters and terminology. In the interest of standardization, we list the characters that should minimally be considered in the description of new phlebotomine taxa as well as annotated illustrations of several characters. For these characters, multiple illustrations are provided to show some of the variations. The preferred terms for all pertinent characters are listed as well as their synonyms in English, Portuguese, and French. Finally, we offer an updated list of abbreviations to be used for generic and subgeneric names. PMID:28730992
Mark, Quentin J
2014-01-01
Human height is a heritable trait that is known to be influenced by environmental factors and general standard of living. Individual and population stature is correlated with health, education and economic achievement. Strong sexual selection pressures for stature have been observed in multiple diverse populations, however; there is significant global variance in gender equality and prohibitions on female mate selection. This paper explores the contribution of general standard of living and gender inequality to the variance in global female population heights. Female population heights of 96 nations were culled from previously published sources and public access databases. Factor analysis with United Nations international data on education rates, life expectancy, incomes, maternal and childhood mortality rates, ratios of gender participation in education and politics, the Human Development Index (HDI) and the Gender Inequality Index (GII) was run. Results indicate that population heights vary more closely with gender inequality than with population health, income or education.
Pataky, Reka; Bremner, Karen E.; Rangrej, Jagadish; Chan, Kelvin K.W.; Cheung, Winson Y.; Hoch, Jeffrey S.; Peacock, Stuart; Krahn, Murray D.
2017-01-01
Background: Costing studies are useful to measure the economic burden of cancer. Comparing costs between healthcare systems can inform evaluation, development or modification of cancer care policies. Objectives: To estimate and compare cancer costs in British Columbia and Ontario from the payers' perspectives. Methods: Using linked cancer registry and administrative data, and standardized costing methodology and analyses, we estimated costs for 21 cancer sites by phase of care to determine potential differences between provinces. Results: Overall, costs were higher in Ontario. Costs were highest in the initial post-diagnosis and pre-death phases and lowest in the pre-diagnosis and continuing phases, and generally higher for brain cancer and multiple myeloma, and lower for melanoma. Hospitalization was the major cost category. Costs for physician services and diagnostic tests differed the most between provinces. Conclusions: The standardization of data and costing methodology is challenging, but it enables interprovincial and international comparative costing analyses. PMID:28277207
Phinney, Karen W; Rimmer, Catherine A; Thomas, Jeanice Brown; Sander, Lane C; Sharpless, Katherine E; Wise, Stephen A
2011-01-01
Vitamins are essential to human health, and dietary supplements containing vitamins are widely used by individuals hoping to ensure they have adequate intake of these important nutrients. Measurement of vitamins in nutritional formulations is necessary to monitor regulatory compliance and in studies examining the nutrient intake of specific populations. Liquid chromatographic methods, primarily with UV absorbance detection, are well established for both fat- and water-soluble measurements, but they do have limitations for certain analytes and may suffer from a lack of specificity in complex matrices. Liquid chromatography-mass spectrometry (LC-MS) provides both sensitivity and specificity for the determination of vitamins in these matrices, and simultaneous analysis of multiple vitamins in a single analysis is often possible. In this work, LC-MS methods were developed for both fat- and water-soluble vitamins and applied to the measurement of these analytes in two NIST Standard Reference Materials. When possible, stable isotope labeled internal standards were employed for quantification.
Wang, Jiang; Jiang, Yao; Wang, Yingwu; Zhao, Xia; Cui, Yimin; Gu, Jingkai
2007-05-09
A simple, sensitive and specific liquid chromatography/tandem mass spectrometry method for the quantitation of aildenafil, a new phosphodiesterase V inhibitor, in human plasma is presented. The analyte and internal standard, sildenafil, were extracted by a one-step liquid-liquid extraction in alkaline conditions and separated on a C(18) column using ammonia:10mM ammonium acetate buffer:methanol (0.1:15:85, v/v/v) as the mobile phase. The detection by an API 4000 triple quadrupole mass spectrometer in multiple-reaction monitoring mode was completed within 2.5 min. The calibration curve exhibited a linear dynamic range of 0.05-100 ng/ml with a 10 pg/ml limit of detection. The intra- and inter-day precisions measured as relative standard deviation were within 8.04% and 5.72%, respectively. This method has been used in a pharmacokinetic study of aildenafil in healthy male volunteers each given an oral administration of one of the three dosages.
Time synchronized video systems
NASA Technical Reports Server (NTRS)
Burnett, Ron
1994-01-01
The idea of synchronizing multiple video recordings to some type of 'range' time has been tried to varying degrees of success in the past. Combining this requirement with existing time code standards (SMPTE) and the new innovations in desktop multimedia however, have afforded an opportunity to increase the flexibility and usefulness of such efforts without adding costs over the traditional data recording and reduction systems. The concept described can use IRIG, GPS or a battery backed internal clock as the master time source. By converting that time source to Vertical Interval Time Code or Longitudinal Time Code, both in accordance with the SMPTE standards, the user will obtain a tape that contains machine/computer readable time code suitable for use with editing equipment that is available off-the-shelf. Accuracy on playback is then determined by the playback system chosen by the user. Accuracies of +/- 2 frames are common among inexpensive systems and complete frame accuracy is more a matter of the users' budget than the capability of the recording system.
Software database creature for investment property measurement according to international standards
NASA Astrophysics Data System (ADS)
Ponomareva, S. V.; Merzliakova, N. A.
2018-05-01
The article deals with investment property measurement and accounting problems at the international, national and enterprise levels. The need to create the software for investment property measurement according to International Accounting Standards was substantiated. The necessary software functions and the processes were described.
Heleniak, Charlotte; King, Kevin M.; Monahan, Kathryn C.; McLaughlin, Katie A.
2017-01-01
Although community violence is an established risk factor for youth aggression, less research has examined its relation with internalizing psychopathology. This study examined associations of community violence exposure with internalizing symptoms, and state and trait emotion dysregulation as mechanisms underlying these associations, in 287 adolescents aged 16–17 (45.6% male; 40.8% White). Community violence exposure was associated with internalizing symptoms, negative affect during peer evaluation, trait emotional reactivity, and infrequent problem solving. Multiple emotion dysregulation indices were also associated with internalizing symptoms. In simultaneous multiple mediator models, indirect effects of community violence on internalizing problems were significantly explained by state and trait emotion dysregulation. Findings implicate emotion dysregulation as one mechanism linking community violence exposure to adolescent internalizing symptoms. PMID:28646545
Standardized protocols for quality control of MRM-based plasma proteomic workflows.
Percy, Andrew J; Chambers, Andrew G; Smith, Derek S; Borchers, Christoph H
2013-01-04
Mass spectrometry (MS)-based proteomics is rapidly emerging as a viable technology for the identification and quantitation of biological samples, such as human plasma--the most complex yet commonly employed biofluid in clinical analyses. The transition from a qualitative to quantitative science is required if proteomics is going to successfully make the transition to a clinically useful technique. MS, however, has been criticized for a lack of reproducibility and interlaboratory transferability. Currently, the MS and plasma proteomics communities lack standardized protocols and reagents to ensure that high-quality quantitative data can be accurately and precisely reproduced by laboratories across the world using different MS technologies. Toward addressing this issue, we have developed standard protocols for multiple reaction monitoring (MRM)-based assays with customized isotopically labeled internal standards for quality control of the sample preparation workflow and the MS platform in quantitative plasma proteomic analyses. The development of reference standards and their application to a single MS platform is discussed herein, along with the results from intralaboratory tests. The tests highlighted the importance of the reference standards in assessing the efficiency and reproducibility of the entire bottom-up proteomic workflow and revealed errors related to the sample preparation and performance quality and deficits of the MS and LC systems. Such evaluations are necessary if MRM-based quantitative plasma proteomics is to be used in verifying and validating putative disease biomarkers across different research laboratories and eventually in clinical laboratories.
1997 DOE technical standards program workshop: Proceedings
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-10-01
The Department of Energy held its annual Technical Standards Program Workshop on July 8--10, 1997, at the Loews L`Enfant Plaza Hotel in Washington, DC. The workshop focused on aspects of implementation of the National Technology Transfer and Advancement Act of 1995 [Public Law (PL) 104-113] and the related revision (still pending) to OMB Circular A119 (OMB A119), Federal Participation in the Development and Use of Voluntary Standards. It also addressed DOE`s efforts in transitioning to a standards-based operating culture, and, through this transition, to change from a developer of internal technical standards to a customer of external technical standards. Themore » workshop was designed to provide a forum to better understand how the new law is affecting Department activities. Panel topics such as ``Public Law 104-113 and Its Influence on Federal Agency Standards Activities`` and ``Update on Global Standards Issues`` provided insight on both the internal and external effects of the new law. Keynote speaker Richard Meier of Meadowbrook International (and formerly the Deputy Assistant US Trade Representative) addressed the subject of international trade balance statistics. He pointed out that increases in US export figures do not necessarily indicate increases in employment. Rather, increased employment results from product growth. Mr Meier also discussed issues such as the US migration to the sue of the metric system, the impact of budget limitations on Government participation in voluntary standards organizations, international standards ISO 9000 and ISO 14000, and DOE`s role in the worldwide transition from weapons production to cleanup.« less
Looking for the Perfect Mentor.
Sá, Ana Pinheiro; Teixeira-Pinto, Cristina; Veríssimo, Rafaela; Vilas-Boas, Andreia; Firmino-Machado, João
2015-01-01
The authors established the profile of the Internal Medicine clinical teachers in Portugal aiming to define a future interventional strategy plan as adequate as possible to the target group and to the problems identified by the residents. Observational, transversal, analytic study. An online anonymous questionnaire was defined, evaluating the demographic characteristics of the clinical teachers, their path in Internal Medicine and their involvement in the residents learning process. We collected 213 valid questionnaires, making for an estimated response rate of 28.4%. Median global satisfaction with the clinical teacher was 4.52 (± 1.33 points) and the classification of the relationship between resident and clinical teacher was 4.86 ± 1.04 points. The perfect clinical teacher is defined by high standards of dedication and responsibility (4.9 ± 1.37 points), practical (4.8 ± 1.12 points) and theoretical skills (4.8 ± 1.07 points). The multiple linear regression model allowed to determine predictors of the residentâs satisfaction with their clinical teacher, justifying 82,5% of the variation of satisfaction with the clinical teacher (R2 = 0.83; R2 a = 0.82). Postgraduate medical education consists of an interaction between several areas of knowledge and intervening variables in the learning process having the clinical teacher in the central role. Overall, the pedagogical abilities were the most valued by the Internal Medicine residents regarding their clinical teacher, as determinants of a quality residentship. This study demonstrates the critical relevance of the clinical teacher in the satisfaction of residents with their residentship. The established multiple linear regression model highlights the impact of the clinical and pedagogical relantionship with the clinical teacher in a relevant increase in the satisfaction with the latter.
Health and safety management systems: liability or asset?
Bennett, David
2002-01-01
Health and safety management systems have a background in theory and in various interests among employers and workplace health and safety professionals. These have resulted in a number of national systems emanating from national standard-writing centres and from employers' organizations. In some cases these systems have been recognized as national standards. The contenders for an international standard have been the International Organization of Standardization (ISO) and the International Labour Organization (ILO). The quality and environmental management systems of ISO indicate what an ISO health and safety management standard would look like. The ILO Guidelines on Safety and Health Management Systems, by contrast, are stringent, specific and potentially effective in improving health and safety performance in the workplace.
The internal consistency of the standard gamble: tests after adjusting for prospect theory.
Oliver, Adam
2003-07-01
This article reports a study that tests whether the internal consistency of the standard gamble can be improved upon by incorporating loss weighting and probability transformation parameters in the standard gamble valuation procedure. Five alternatives to the standard EU formulation are considered: (1) probability transformation within an EU framework; and, within a prospect theory framework, (2) loss weighting and full probability transformation, (3) no loss weighting and full probability transformation, (4) loss weighting and no probability transformation, and (5) loss weighting and partial probability transformation. Of the five alternatives, only the prospect theory formulation with loss weighting and no probability transformation offers an improvement in internal consistency over the standard EU valuation procedure.
Future Direction of IMIA Standardization
Kimura, M.; Ogishima, S.; Shabo, A.; Kim, I. K.; Parisot, C.; de Faria Leao, B.
2014-01-01
Summary Objectives Standardization in the field of health informatics has increased its importance and global alliance for establishing interoperability and compatibility internationally. Standardization has been organized by standard development organizations (SDOs) such as ISO (International Organization for Standardization), CEN (European Committee for Standardization), IHE (Integrating the Healthcare Enterprise), and HL7 (Health Level 7), etc. This paper reports the status of these SDOs’ activities. Methods In this workshop, we reviewed the past activities and the current situation of standardization in health care informatics with the standard development organizations such as ISO, CEN, IHE, and HL7. Then we discussed the future direction of standardization in health informatics toward “future medicine” based on standardized technologies. Results We could share the status of each SDO through exchange of opinions in the workshop. Some WHO members joined our discussion to support this constructive activity. Conclusion At this meeting, the workshop speakers have been appointed as new members of the IMIA working groups of Standards in Health Care Informatics (WG16). We could reach to the conclusion that we collaborate for the international standardization in health informatics toward “future medicine”. PMID:25123729
Environmental Analytical Measurement Uncertainty Estimation: Nested Hierarchical Approach
2001-01-01
recognized. The International Organization of Standardization ( ISO / IEC 17025 ) standard for the general requirements for competence of testing and...Uncertainty in Measurement” (GUM) was published by the International Organization of Standardization ( ISO ) in collaboration with the seven member...the American National Standards Institute (ANSI) adoption of the ISO GUM. The ANSI adoption of the ISO GUM provides the mathematical model and
Miura, Tsutomu; Chiba, Koichi; Kuroiwa, Takayoshi; Narukawa, Tomohiro; Hioki, Akiharu; Matsue, Hideaki
2010-09-15
Neutron activation analysis (NAA) coupled with an internal standard method was applied for the determination of As in the certified reference material (CRM) of arsenobetaine (AB) standard solutions to verify their certified values. Gold was used as an internal standard to compensate for the difference of the neutron exposure in an irradiation capsule and to improve the sample-to-sample repeatability. Application of the internal standard method significantly improved linearity of the calibration curve up to 1 microg of As, too. The analytical reliability of the proposed method was evaluated by k(0)-standardization NAA. The analytical results of As in AB standard solutions of BCR-626 and NMIJ CRM 7901-a were (499+/-55)mgkg(-1) (k=2) and (10.16+/-0.15)mgkg(-1) (k=2), respectively. These values were found to be 15-20% higher than the certified values. The between-bottle variation of BCR-626 was much larger than the expanded uncertainty of the certified value, although that of NMIJ CRM 7901-a was almost negligible. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Ni, Kuei-Jung
2013-01-01
Most international health-related standards are voluntary per se. However, the incorporation of international standard-making into WTO agreements like the SPS Agreement has drastically changed the status and effectiveness of the standards. WTO members are urged to follow international standards, even when not required to comply fully with them. Indeed, such standards have attained great influence in the trade system. Yet evidence shows that the credibility of the allegedly scientific approach of these international standard-setting institutions, especially the Codex Alimentarius Commission (Codex) governing food safety standards, has been eroded and diluted by industrial and political influences. Its decision-making is no longer based on consensus, but voting. The adoption of new safety limits for the veterinary drug ractopamine in 2012, by a very close vote, is simply another instance of the problematic operations of the Codex. These dynamics have led skeptics to question the legitimacy of the standard setting body and to propose solutions to rectify the situation. Prior WTO rulings have yet to pay attention to the defect in the decision-making processes of the Codex. Nevertheless, the recent Appellate Body decision on Hormones II is indicative of a deferential approach to national measures that are distinct from Codex formulas. The ruling also rejects the reliance on those experts who authored the Codex standards to assess new measures of the European Community. This approach provides an opportunity to contemplate what the proper relationship between the WTO and Codex ought to be. Through a critical review of WTO rulings and academic proposals, this article aims to analyze how the WTO ought to define such interactions and respond to the politicized standard-making process in an optimal manner. This article argues that building a more systematic approach and normative basis for WTO judicial review of standard-setting decisions and the selection of technical experts would be instrumental to strengthening the mutual supports between the WTO and international standard-setting organizations, and may help avoid the introduction of a prejudice toward a justified science finding.
Calder, W.; Snyder, D.; Burr, J.F.
2018-01-01
This paper provides a determination of the equivalent level of protection of the international standards relative to similar criteria used by the U.S. Mine Safety and Health Administration (MSHA) to approve two-fault intrinsically safe (IS) stand-alone equipment. U.S. mining law requires such a determination for MSHA to use alternatives to existing standards. The primary issue is to demonstrate that the international standards for equipment evaluation will provide at least the same level of protection for miners as the document currently used by MSHA. PMID:29780219
Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher
NASA Technical Reports Server (NTRS)
Butz, James R.; Turchi, Craig S.; Kimball, Amanda; McKinnon, Thomas; Riedel, Edward
2010-01-01
A fine-water-mist fire-suppression device has been designed so that it can be discharged uniformly in any orientation via a high-pressure gas propellant. Standard fire extinguishers used while slightly tilted or on their side will not discharge all of their contents. Thanks to the new design, this extinguisher can be used in multiple environments such as aboard low-gravity spacecraft, airplanes, and aboard vehicles that may become overturned prior to or during a fire emergency. Research in recent years has shown that fine water mist can be an effective alternative to Halons now banned from manufacture. Currently, NASA uses carbon dioxide for fire suppression on the International Space Station (ISS) and Halon chemical extinguishers on the space shuttle. While each of these agents is effective, they have drawbacks. The toxicity of carbon dioxide requires that the crew don breathing apparatus when the extinguishers are deployed on the ISS, and Halon use in future spacecraft has been eliminated because of international protocols on substances that destroy atmospheric ozone. A major advantage to the new system on occupied spacecraft is that the discharged system is locally rechargeable. Since the only fluids used are water and nitrogen, the system can be recharged from stores of both carried aboard the ISS or spacecraft. The only support requirement would be a pump to fill the water and a compressor to pressurize the nitrogen propellant gas. This system uses a gaseous agent to pressurize the storage container as well as to assist in the generation of the fine water mist. The portable fire extinguisher hardware works like a standard fire extinguisher with a single storage container for the agents (water and nitrogen), a control valve assembly for manual actuation, and a discharge nozzle. The design implemented in the proof-of-concept experiment successfully extinguished both open fires and fires in baffled enclosures.
Polak, Michel; Blair, Jo; Kotnik, Primoz; Pournara, Effie; Pedersen, Birgitte Tønnes; Rohrer, Tilman R
2017-11-01
To investigate the effect of age at growth hormone (GH) treatment start on near adult height (NAH) in children with isolated GH deficiency (GHD). NordiNet® International Outcome Study (IOS) (Nbib960128), a non-interventional, multicentre study, evaluates the long-term effectiveness and safety of Norditropin® (somatropin) (Novo Nordisk A/S) in the real-life clinical setting. Patients ( n = 172) treated to NAH (height at ≥18 years, or height velocity <2 cm/year at ≥16 (boys) or ≥15 (girls) years) were grouped by age (years) at treatment start (early (girls, <8; boys, <9), intermediate (girls, 8-10; boys, 9-11) or late (girls, >10; boys, >11)) and GHD severity (<3 ng/mL or 3 to ≤10 ng/mL). Multiple regression analysis was used to evaluate the effect of age at treatment start (as a categorical and continuous variable) on NAH standard deviation score (SDS). Age at treatment start had a marked effect on NAH SDS; NAH SDS achieved by patients starting treatment early ( n = 40 (boys, 70.0%); least squares mean (standard error) -0.76 (0.14)) exceeded that achieved by those starting later (intermediate, n = 42 (boys, 57.1%); -1.14 (0.15); late, n = 90 (boys, 68.9%); -1.21 (0.10)). Multiple regression analysis showed a significant association between NAH SDS and age at treatment start ( P < 0.0242), baseline height SDS (HSDS) ( P < 0.0001), target HSDS ( P < 0.0001), and GHD severity ( P = 0.0012). Most (78.5%) patients achieved a normal NAH irrespective of age at treatment start. Early initiation of GH treatment in children with isolated GHD improves their chance of achieving their genetic height potential. © 2017 The authors.
The use of heart rate variability in assessing precompetitive stress in high-standard judo athletes.
Morales, J; Garcia, V; García-Massó, X; Salvá, P; Escobar, R; Buscà, B
2013-02-01
The objective of this study is to examine the sensitivity to and changes in heart rate variability (HRV) in stressful situations before judo competitions and to observe the differences among judo athletes according to their competitive standards in both official and unofficial competitions. 24 (10 male and 14 female) national- and international-standard athletes were evaluated. Each participant answered the Revised Competitive State Anxiety Inventory (CSAI-2R) and their HRV was recorded both during an official and unofficial competition. The MANOVA showed significant main effects of the athlete's standard and the type of competition in CSAI-2R, in HRV time domain, in HRV frequency domain and in HRV nonlinear analysis (p<0.05). International-standard judo athletes have lower somatic anxiety, cognitive anxiety, heart rate and low-high frequency ratio than national-standard athletes (p<0.05). International-standard athletes have a higher confidence, mean RR interval, standard deviation of RR, square root of the mean squared difference of successive RR intervals, number of consecutive RR that differ by more than 5 ms, short-term variability, long-term variability, long-range scaling exponents and short-range scaling exponent than national-standard judo athletes. In conclusion, international-standard athletes show less pre-competitive anxiety than the national-standard athletes and HRV analysis is sensitive to changes in pre-competitive anxiety. © Georg Thieme Verlag KG Stuttgart · New York.
Chambers, Brian; Chambers, Jayne; Churilov, Leonid; Cameron, Heather; Macdonell, Richard
2014-09-01
We evaluated internal jugular vein and vertebral vein volume flow using ultrasound, in patients with clinically isolated syndrome or mild multiple sclerosis and controls, to determine whether volume flow was different between the two groups. In patients and controls, internal jugular vein volume flow increased from superior to inferior segments, consistent with recruitment from collateral veins. Internal jugular vein and vertebral vein volume flow were greater on the right in supine and sitting positions. Internal jugular vein volume flow was higher in the supine posture. Vertebral vein volume flow was higher in the sitting posture. Regression analyses of cube root transformed volume flow data, adjusted for supine/sitting, right/left and internal jugular vein/vertebral vein, revealed no significant difference in volume flow in patients compared to controls. Our findings further refute the concept of venous obstruction as a causal factor in the pathogenesis of multiple sclerosis. Control volume flow data may provide useful normative reference values. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Multi-functional Chassis-based Antennas Using Characteristic Mode Theory
NASA Astrophysics Data System (ADS)
Kishor, Krishna Kumar
Designing antennas for handheld devices is quite challenging primarily due to the limited real-estate available, and the fact that internal antennas occupy a large volume. With the need to support a variety of radio systems such as GSM, LTE and WiFi that operate in a wide range of frequency bands, multi-band, wideband and frequency reconfigurable antenna designs have been explored in the literature. Moreover, to support higher data rates, the Long Term Evolution Advanced (LTE-A) standard has been introduced, which requires supporting multiple input multiple output (MIMO) antenna technology and carrier aggregation (CA) on a handheld device. Both of these benefit from the use of multiple antennas or multi-port antennas, but with the limited space available, adding more internal antennas may not be easily possible. Additionally, to realize the benefits of these technologies the multiple antenna ports have to be well isolated from each other. This thesis explores the utilization of the ground plane (or chassis) of a handheld device as an antenna to meet some of these challenges. To achieve this, the theory of characteristic modes (TCM) for conducting bodies is relied upon, to determine the eigen-currents supported on the chassis. The orthogonality properties of these eigencurrents, and their corresponding far-field eigenfields (electric and magnetic) makes TCM a good tool to design multiple antennas with high isolation. This is demonstrated in this thesis via the design of four chassis-based antennas that have different functionalities. The first design is a two port MIMO antenna utilizing a combination of eigenmodes to achieve port isolation. The second design is a pattern reconfigurable MIMO antenna that can operate in two states at 2.28 GHz. The third design is a four port antenna that operates in three frequency bands, with two bands below 1 GHz for CA and the remaining two ports for MIMO communication. The final design is a five port antenna that supports MIMO operation in two frequency bands along with an additional port for CA in the third band. The four designs have been experimentally verified, validating the use of TCM as a versatile tool to design multi-functional chassis-based antennas.
ISO 9000: The Librarian's Role.
ERIC Educational Resources Information Center
Dobson, Chris; Ernst, Carolyn
1999-01-01
Describes the special library's role in implementing ISO 9000 (i.e., a series of international quality-assurance standards developed by the International Organization of Standards). Topics discussed include document and data control, keeping the standards current, documentation of procedures, the ISO 9000 audit, and benefits for the library. (MES)
Ono, Tomohiro; Nakamura, Mitsuhiro; Hirose, Yoshinori; Kitsuda, Kenji; Ono, Yuka; Ishigaki, Takashi; Hiraoka, Masahiro
2017-09-01
To estimate the lung tumor position from multiple anatomical features on four-dimensional computed tomography (4D-CT) data sets using single regression analysis (SRA) and multiple regression analysis (MRA) approach and evaluate an impact of the approach on internal target volume (ITV) for stereotactic body radiotherapy (SBRT) of the lung. Eleven consecutive lung cancer patients (12 cases) underwent 4D-CT scanning. The three-dimensional (3D) lung tumor motion exceeded 5 mm. The 3D tumor position and anatomical features, including lung volume, diaphragm, abdominal wall, and chest wall positions, were measured on 4D-CT images. The tumor position was estimated by SRA using each anatomical feature and MRA using all anatomical features. The difference between the actual and estimated tumor positions was defined as the root-mean-square error (RMSE). A standard partial regression coefficient for the MRA was evaluated. The 3D lung tumor position showed a high correlation with the lung volume (R = 0.92 ± 0.10). Additionally, ITVs derived from SRA and MRA approaches were compared with ITV derived from contouring gross tumor volumes on all 10 phases of the 4D-CT (conventional ITV). The RMSE of the SRA was within 3.7 mm in all directions. Also, the RMSE of the MRA was within 1.6 mm in all directions. The standard partial regression coefficient for the lung volume was the largest and had the most influence on the estimated tumor position. Compared with conventional ITV, average percentage decrease of ITV were 31.9% and 38.3% using SRA and MRA approaches, respectively. The estimation accuracy of lung tumor position was improved by the MRA approach, which provided smaller ITV than conventional ITV. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Nazare, P; Massaroti, P; Duarte, L F; Campos, D R; Marchioretto, M A M; Bernasconi, G; Calafatti, S; Barros, F A P; Meurer, E C; Pedrazzoli, J; Moraes, L A B
2005-09-01
A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method for the quantification of bromopride I in human plasma is presented. Sample preparation consisted of the addition of procainamide II as the internal standard, liquid-liquid extraction in alkaline conditions using hexane-ethyl acetate (1 : 1, v/v) as the extracting solvent, followed by centrifugation, evaporation of the solvent and sample reconstitution in acetonitrile. Both I and II (internal standard, IS) were analyzed using a C18 column and the mobile-phase acetonitrile-water (formic acid 0.1%). The eluted compounds were monitored using electrospray tandem mass spectrometry. The analyses were carried out by multiple reaction monitoring (MRM) using the parent-to-daughter combinations of m/z 344.20 > 271.00 and m/z 236.30 > 163.10. The areas of peaks from analyte and IS were used for quantification of I. The achieved limit of quantification was 1.0 ng/ml and the assay exhibited a linear dynamic range of 1-100.0 ng/ml and gave a correlation coefficient (r) of 0.995 or better. Validation results on linearity, specificity, accuracy, precision and stability, as well as application to the analysis of samples taken up to 24 h after oral administration of 10 mg of I in healthy volunteers demonstrated the applicability to bioequivalence studies.
Chen, Xiabin; Zheng, Xirong; Ding, Kai; Zhou, Ziyuan; Zhan, Chang-Guo; Zheng, Fang
2016-01-01
As new metabolic pathways of cocaine were recently identified, a high performance liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed to simultaneously determine cocaine and nine cocaine-related metabolites in whole blood samples. One-step solid phase extraction was used to extract all of the ten compounds and corresponding internal standards from blood samples. All compounds and internal standards extracted were separated on an Atlantis T3 (100Å, 3 µm, 2.1 mm × 150 mm I.D) column and detected in positive ion and high sensitivity mode with multiple reaction monitoring. This method was validated for its sensitivity, linearity, specificity, accuracy, precision, recovery, and stability. All of the ten compounds were quantifiable ranging from the lower limit of quantification (LLOQs) of ~10 nM (1.9–3.2 ng/ml) to ~1000 nM (190–320 ng/ml) without any interfering substance. Accuracy and precision were determined, and both of them were within the acceptance criteria of the United States (US) Food and Drug Administration (FDA) and European Medicines Agency (EMA) guidelines. The recovery was above 66.7% for all compounds. Stability tests demonstrated the stability of compounds under different storage conditions in whole blood samples. The method was successfully applied to a pharmacokinetic study with co-administration of cocaine and alcohol in rats. PMID:27923200
Determination of ambroxol in human plasma using LC-MS/MS.
Kim, Hohyun; Yoo, Jeong-Yeon; Han, Sang Beom; Lee, Hee Joo; Lee, Kyung Ryul
2003-06-01
A sensitive and selective liquid chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) was developed for the quantification of ambroxol in human plasma. Domperidone was used as internal standard, with plasma samples extracted using diethyl ether under basic condition. A centrifuged upper layer was then evaporated and reconstituted with 200 microl methanol. The reconstituted samples were injected into a C(18) XTerra MS column (2.1 x 30 mm) with 3.5 microm particle size. The analytical column lasted for at least 600 injections. The mobile phase was composed of 20 mM ammonium acetate in 90% acetonitrile (pH 8.8), with flow rate at 250 microl/min. The mass spectrometer was operated in positive ion mode using turbo electrospray ionization. Nitrogen was used as the nebulizer, curtain, collision, and auxiliary gases. Using MS/MS with multiple reaction monitoring (MRM) mode, ambroxol was detected without severe interferences from plasma matrix. Ambroxol produced a protonated precursor ion ([M+H](+)) at m/z 379 and a corresponding product ion at m/z 264. And internal standard (domperidone) produced a protonated precursor ion ([M+H](+)) at m/z 426 and a corresponding product ion at m/z 174. Detection of ambroxol in human plasma was accurate and precise, with quantification limit at 0.2 ng/ml. This method has been successfully applied to a study of ambroxol in human specimens.
Creelman, R A; Mullet, J E
1995-01-01
Jasmonic acid (JA) is a naturally occurring growth regulator found in higher plants. Several physiological roles have been described for this compound (or a related compound, methyl jasmonate) during plant development and in response to biotic and abiotic stress. To accurately determine JA levels in plant tissue, we have synthesized JA containing 13C for use as an internal standard with an isotopic composition of [225]:[224] 0.98:0.02 compared with [225]:[224] 0.15:0.85 for natural material. GC analysis (flame ionization detection and MS) indicate that the internal standard is composed of 92% 2-(+/-)-[13C]JA and 8% 2-(+/-)-7-iso-[13C]JA. In soybean plants, JA levels were highest in young leaves, flowers, and fruit (highest in the pericarp). In soybean seeds and seedlings, JA levels were highest in the youngest organs including the hypocotyl hook, plumule, and 12-h axis. In soybean leaves that had been dehydrated to cause a 15% decrease in fresh weight, JA levels increased approximately 5-fold within 2 h and declined to approximately control levels by 4 h. In contrast, a lag time of 1-2 h occurred before abscisic acid accumulation reached a maximum. These results will be discussed in the context of multiple pathways for JA biosynthesis and the role of JA in plant development and responses to environmental signals. PMID:11607536
Creelman, R A; Mullet, J E
1995-05-09
Jasmonic acid (JA) is a naturally occurring growth regulator found in higher plants. Several physiological roles have been described for this compound (or a related compound, methyl jasmonate) during plant development and in response to biotic and abiotic stress. To accurately determine JA levels in plant tissue, we have synthesized JA containing 13C for use as an internal standard with an isotopic composition of [225]:[224] 0.98:0.02 compared with [225]:[224] 0.15:0.85 for natural material. GC analysis (flame ionization detection and MS) indicate that the internal standard is composed of 92% 2-(+/-)-[13C]JA and 8% 2-(+/-)-7-iso-[13C]JA. In soybean plants, JA levels were highest in young leaves, flowers, and fruit (highest in the pericarp). In soybean seeds and seedlings, JA levels were highest in the youngest organs including the hypocotyl hook, plumule, and 12-h axis. In soybean leaves that had been dehydrated to cause a 15% decrease in fresh weight, JA levels increased approximately 5-fold within 2 h and declined to approximately control levels by 4 h. In contrast, a lag time of 1-2 h occurred before abscisic acid accumulation reached a maximum. These results will be discussed in the context of multiple pathways for JA biosynthesis and the role of JA in plant development and responses to environmental signals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barbareschi, Daniele; et al.
We describe a general purpose detector ( "Fourth Concept") at the International Linear Collider (ILC) that can measure with high precision all the fundamental fermions and bosons of the standard model, and thereby access all known physics processes. The 4th concept consists of four basic subsystems: a pixel vertex detector for high precision vertex definitions, impact parameter tagging and near-beam occupancy reduction; a Time Projection Chamber for robust pattern recognition augmented with three high-precision pad rows for precision momentum measurement; a high precision multiple-readout fiber calorimeter, complemented with an EM dual-readout crystal calorimeter, for the energy measurement of hadrons, jets,more » electrons, photons, missing momentum, and the tagging of muons; and, an iron-free dual-solenoid muon system for the inverse direction bending of muons in a gas volume to achieve high acceptance and good muon momentum resolution. The pixel vertex chamber, TPC and calorimeter are inside the solenoidal magnetic field. All four subsytems separately achieve the important scientific goal to be 2-to-10 times better than the already excellent LEP detectors, ALEPH, DELPHI, L3 and OPAL. All four basic subsystems contribute to the identification of standard model partons, some in unique ways, such that consequent physics studies are cogent. As an integrated detector concept, we achieve comprehensive physics capabilities that puts all conceivable physics at the ILC within reach.« less
Xiong, Wei; Tao, Xiaoqiu; Pang, Su; Yang, Xue; Tang, GangLing; Bian, Zhaoyang
2014-01-01
A method for the determination of three acidic herbicides, dicamba, 2,4-dichlorophenoxyacetic acid (2,4-D) and 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) in tobacco and soil has been developed based on the use of liquid-liquid extraction and dispersive solid-phase extraction (dispersive-SPE) followed by UPLC-MS/MS. Two percentage of (v/v) formic acid in acetonitrile as the extraction helped partitioning of analytes into the acetonitrile phase. The extract was then cleaned up by dispersive-SPE using primary secondary amine as selective sorbents. Quantitative analysis was done in the multiple-reaction monitoring mode using stable isotope-labeled internal standards for each compound. A separate internal standard for each analyte is required to minimize sample matrix effects on each analyte, which can lead to poor analyte recoveries and decreases in method accuracy and precision. The total analysis time was <4 min. The linear range of the method was from 1 to 100 ng mL(-1) with a limit of detection of each herbicide varied from 0.012 to 0.126 ng g(-1). The proposed method is faster, more sensitive and selective than the traditional methods and more accurate and robust than the published LC-MS/MS methods. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
An Experimental Study of the Internal Consistency of Judgments Made in Bookmark Standard Setting
ERIC Educational Resources Information Center
Clauser, Brian E.; Baldwin, Peter; Margolis, Melissa J.; Mee, Janet; Winward, Marcia
2017-01-01
Validating performance standards is challenging and complex. Because of the difficulties associated with collecting evidence related to external criteria, validity arguments rely heavily on evidence related to internal criteria--especially evidence that expert judgments are internally consistent. Given its importance, it is somewhat surprising…
77 FR 33950 - Prudential Management and Operations Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-08
... by guideline. 12 U.S.C. 4513b. Those 10 areas relate to: Adequacy of internal controls and information systems; adequacy and independence of the internal audit systems; management of interest rate risk... Join Bank Letter at 7-8. 4. Standard 1 (Internal Controls and Information Systems) \\22\\ \\22\\ The Joint...
ERIC Educational Resources Information Center
Thammasat Univ., Bangkok (Thailand). Univ. Libraries.
This document which covers the proceedings of the 1989 International Symposium on Information Technology, begins with several opening ceremony messages and includes the following papers: (1) "Reflections on International Bibliographic Standards" (Winston D. Roberts); (2) "Bibliographic Control from the User's Perspective" (Ruth…
Nobody Seems to Speak English Here Today: Enhancing Assessment and Training in Aviation English
ERIC Educational Resources Information Center
Douglas, Dan
2014-01-01
In 2003 the International Civil Aviation Organization (ICAO) strengthened the provisions that English be made available for international radiotelephony communication. ICAO also developed standards for English proficiency for international pilots and air traffic controllers. However, these standards are applied variably from country to country and…
ERIC Educational Resources Information Center
Virginia State General Assembly, Richmond. House.
This study of existing guidelines and standards for international travel by students in local school divisions is the result of a Virginia Department of Education team effort over four months. The interdisciplinary team reviewed guidelines and standards for international travel and student exchange programs from major organizations and developed…
NASA Technical Reports Server (NTRS)
Hirsch, David B.
2010-01-01
This slide presentation reviews some of the lessons learned in the sphere of international cooperation during the development, assembly and operation of the International Space Station. From the begining all Partners shared a common objective to build, operate and utilize a crewed laboratory in low orbit as an international partnership. The importance of standards is emphasized.
Zanelli, Ugo; Michna, Thomas; Petersson, Carl
2018-03-26
1. A novel method utilizing an internal standard in hepatocytes incubations has been developed and demonstrated to decrease the variability in the determination of intrinsic clearance (CL int ) in this system. The reduced variability was shown to allow differentiation of lower elimination rate constants from noise. 2. The suggested method was able to compensate for a small but systematic error (0.5 µL/min/10 6 cells) caused by an evaporation of approximately 15% of the volume during the incubation time. 3. The approach was validated using six commercial drugs (ketoprofen, tolbutamide, phenacetin, etodolac and quinidine) which were metabolized by different pathways. 4. The suggested internal standard, MSC1815677, was extensively characterized and the acquired data suggest that it fulfills the requirements of an internal standard present during the incubation. The proposed internal standard was stable during the incubation and showed a low potential to inhibit drug metabolizing enzymes and transporters. With MSC1815677 we propose a novel simple, robust and cost-effective method to address the challenges in the estimation of low clearance in hepatocyte incubations.
Building SAWE Capability as an ANSI Accredited Standards Developer
NASA Technical Reports Server (NTRS)
Cerro, Jeffrey A.; Davis, Ed; Peterson, Eric; Griffiths, William T.; Brooks, Andy; Stratton, Bonnie; Attar, Jose
2014-01-01
This paper presents a 2014 status of the Society of Allied Weight Engineers' process towards becoming an Accredited Standards Developer (ASD) under certification by the United States American National Standards Institute (ANSI). Included is material from the committee's 2013 International presentation, current status, and additional general background material. The document strives to serve as a reference point to assist SAWE Recommended Practice and Standards developers in negotiating United States Standards Strategy, international standards strategy, and the association of SAWE standards and recommended practices to those efforts. Required procedures for SAWE to develop and maintain Recommended Practices and ANSI/SAWE Standards are reviewed.
Fibrinolysis standards: a review of the current status.
Thelwell, C
2010-07-01
Biological standards are used to calibrate measurements of components of the fibrinolytic system, either for assigning potency values to therapeutic products, or to determine levels in human plasma as an indicator of thrombotic risk. Traditionally WHO International Standards are calibrated in International Units based on consensus values from collaborative studies. The International Unit is defined by the response activity of a given amount of the standard in a bioassay, independent of the method used. Assay validity is based on the assumption that both standard and test preparation contain the same analyte, and the response in an assay is a true function of this analyte. This principle is reflected in the diversity of source materials used to prepare fibrinolysis standards, which has depended on the contemporary preparations they were employed to measure. With advancing recombinant technology, and improved analytical techniques, a reference system based on reference materials and associated reference methods has been recommended for future fibrinolysis standards. Careful consideration and scientific judgement must however be applied when deciding on an approach to develop a new standard, with decisions based on the suitability of a standard to serve its purpose, and not just to satisfy a metrological ideal. 2010 The International Association for Biologicals. Published by Elsevier Ltd. All rights reserved.
The international development of forensic science standards - A review.
Wilson-Wilde, Linzi
2018-04-16
Standards establish specifications and procedures designed to ensure products, services and systems are safe, reliable and consistently perform as intended. Standards can be used in the accreditation of forensic laboratories or facilities and in the certification of products and services. In recent years there have been various international activities aiming at developing forensic science standards and guidelines. The most significant initiative currently underway within the global forensic community is the development of International Organization for Standardization (ISO) standards. This paper reviews the main bodies working on standards for forensic science, the processes used and the implications for accreditation. This paper specifically discusses the work of ISO Technical Committee TC272, the future TC272 work program for the development of forensic science standards and associated timelines. Also discussed, are the lessons learnt to date in navigating the complex environment of multi-country stakeholder deliberations in standards development. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.
Doyle, E; Fowles, S E; Summerfield, S; White, T J
2002-03-25
A method was developed for the determination of tafenoquine (I) in human plasma using high-performance liquid chromatography-tandem mass spectrometry. Prior to analysis, the protein in plasma samples was precipitated with methanol containing [2H3(15N)]tafenoquine (II) to act as an internal standard. The supernatant was injected onto a Genesis-C18 column without any further clean-up. The mass spectrometer was operated in the positive ion mode, employing a heat assisted nebulisation, electrospray interface. Ions were detected in multiple reaction monitoring mode. The assay required 50 microl of plasma and was precise and accurate within the range 2 to 500 ng/ml. The average within-run and between-run relative standard deviations were < 7% at 2 ng/ml and greater concentrations. The average accuracy of validation standards was generally within +/- 4% of the nominal concentration. There was no evidence of instability of I in human plasma following three complete freeze-thaw cycles and samples can safely be stored for at least 8 months at approximately -70 degrees C. The method was very robust and has been successfully applied to the analysis of clinical samples from patients and healthy volunteers dosed with I.