Effects of electrofishing gear type on spatial and temporal variability in fish community sampling
Meador, M.R.; McIntyre, J.P.
2003-01-01
Fish community data collected from 24 major river basins between 1993 and 1998 as part of the U.S. Geological Survey's National Water-Quality Assessment Program were analyzed to assess multiple-reach (three consecutive reaches) and multiple-year (three consecutive years) variability in samples collected at a site. Variability was assessed using the coefficient of variation (CV; SD/mean) of species richness, the Jaccard index (JI), and the percent similarity index (PSI). Data were categorized by three electrofishing sample collection methods: backpack, towed barge, and boat. Overall, multiple-reach CV values were significantly lower than those for multiple years, whereas multiple-reach JI and PSI values were significantly greater than those for multiple years. Multiple-reach and multiple-year CV values did not vary significantly among electrofishing methods, although JI and PSI values were significantly greatest for backpack electrofishing across multiple reaches and multiple years. The absolute difference between mean species richness for multiple-reach samples and mean species richness for multiple-year samples was 0.8 species (9.5% of total species richness) for backpack samples, 1.7 species (10.1%) for towed-barge samples, and 4.5 species (24.4%) for boat-collected samples. Review of boat-collected fish samples indicated that representatives of four taxonomic families - Catostomidae, Centrarchidae, Cyprinidae, and Ictaluridae - were collected at all sites. Of these, catostomids exhibited greater interannual variability than centrarchids, cyprinids, or ictalurids. Caution should be exercised when combining boat-collected fish community data from different years because of relatively high interannual variability, which is primarily due to certain relatively mobile species. Such variability may obscure longer-term trends.
Composite analysis for Escherichia coli at coastal beaches
Bertke, E.E.
2007-01-01
At some coastal beaches, concentrations of fecal-indicator bacteria can differ substantially between multiple points at the same beach at the same time. Because of this spatial variability, the recreational water quality at beaches is sometimes determined by stratifying a beach into several areas and collecting a sample from each area to analyze for the concentration of fecal-indicator bacteria. The average concentration of bacteria from those points is often used to compare to the recreational standard for advisory postings. Alternatively, if funds are limited, a single sample is collected to represent the beach. Compositing the samples collected from each section of the beach may yield equally accurate data as averaging concentrations from multiple points, at a reduced cost. In the study described herein, water samples were collected at multiple points from three Lake Erie beaches and analyzed for Escherichia coli on modified mTEC agar (EPA Method 1603). From the multiple-point samples, a composite sample (n = 116) was formed at each beach by combining equal aliquots of well-mixed water from each point. Results from this study indicate that E. coli concentrations from the arithmetic average of multiple-point samples and from composited samples are not significantly different (t = 1.59, p = 0.1139) and yield similar measures of recreational water quality; additionally, composite samples could result in a significant cost savings.
Huffman, Raegan L.
2002-01-01
Ground-water samples were collected in April 1999 at Naval Air Station Whidbey Island, Washington, with passive diffusion samplers and a submersible pump to compare concentrations of volatile organic compounds (VOCs) in water samples collected using the two sampling methods. Single diffusion samplers were installed in wells with 10-foot screened intervals, and multiple diffusion samplers were installed in wells with 20- to 40-foot screened intervals. The diffusion samplers were recovered after 20 days and the wells were then sampled using a submersible pump. VOC concentrations in the 10-foot screened wells in water samples collected with diffusion samplers closely matched concentrations in samples collected with the submersible pump. Analysis of VOC concentrations in samples collected from the 20- to 40-foot screened wells with multiple diffusion samplers indicated vertical concentration variation within the screened interval, whereas the analysis of VOC concentrations in samples collected with the submersible pump indicated mixing during pumping. The results obtained using the two sampling methods indicate that the samples collected with the diffusion samplers were comparable with and can be considerably less expensive than samples collected using a submersible pump.
Replacing missing data between airborne SAR coherent image pairs
Musgrove, Cameron H.; West, James C.
2017-07-31
For synthetic aperture radar systems, missing data samples can cause severe image distortion. When multiple, coherent data collections exist and the missing data samples do not overlap between collections, there exists the possibility of replacing data samples between collections. For airborne radar, the known and unknown motion of the aircraft prevents direct data sample replacement to repair image features. Finally, this paper presents a method to calculate the necessary phase corrections to enable data sample replacement using only the collected radar data.
Replacing missing data between airborne SAR coherent image pairs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Musgrove, Cameron H.; West, James C.
For synthetic aperture radar systems, missing data samples can cause severe image distortion. When multiple, coherent data collections exist and the missing data samples do not overlap between collections, there exists the possibility of replacing data samples between collections. For airborne radar, the known and unknown motion of the aircraft prevents direct data sample replacement to repair image features. Finally, this paper presents a method to calculate the necessary phase corrections to enable data sample replacement using only the collected radar data.
Chapman, Kent; Favaloro, Emmanuel J
2018-05-01
The Multiplate is a popular instrument that measures platelet function using whole blood. Potentially considered a point of care instrument, it is also used by hemostasis laboratories. The instrument is usually utilized to assess antiplatelet medication or as a screen of platelet function. According to the manufacturer, testing should be performed within 0.5-3 hours of blood collection, and preferably using manufacturer provided hirudin tubes. We report time-associated reduction in platelet aggregation using the Multiplate and hirudin blood collection tubes, for all the major employed agonists. Blood for Multiplate analysis was collected into manufacturer supplied hirudin tubes, and 21 consecutive samples assessed using manufacturer supplied agonists (ADP, arachidonic acid, TRAP, collagen and ristocetin), at several time-points post-sample collection within the recommended test time period. Blood was also collected into EDTA as a reference method for platelet counts, with samples collected into sodium citrate and hirudin used for comparative counts. All platelet agonists showed a diminution of response with time. Depending on the agonist, the reduction caused 5-20% and 22-47% of responses initially in the normal reference range to fall below the reference range at 120min and 180min, respectively. Considering any agonist, 35% and 67% of initially "normal" responses became 'abnormal' at 120 min and 180 min, respectively. Platelet counts showed generally minimal changes in EDTA blood, but were markedly reduced over time in both citrate and hirudin blood, with up to 40% and 60% reduction, respectively, at 240 min. The presence of platelet clumping (micro-aggregate formation) was also observed in a time dependent manner, especially for hirudin. In conclusion, considering any platelet agonist, around two-thirds of samples can, within the recommended 0.5-3 hour testing window post-blood collection, yield a reduction in platelet aggregation that may lead to a change in interpretation (i.e., normal to reduced). Thus, the stability of Multiplate testing can more realistically be considered as being between 30-120 min of blood collection for samples collected into hirudin.
A single-sampling hair trap for mesocarnivores
Jonathan N. Pauli; Matthew B. Hamilton; Edward B. Crain; Steven W. Buskirk
2007-01-01
Although techniques to analyze and quantifY DNA-based data have progressed, methods to noninvasively collect samples lag behind. Samples are generally collected from devices that permit coincident sampling of multiple individuals. Because of cross-contamination, substantive genotyping errors can arise. We developed a cost-effective (US$4.60/trap) single-capture hair...
40 CFR 141.703 - Sampling locations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... multiple plants draw water from the same influent, such as the same pipe or intake, the State may approve...) The State may approve a system to collect a source water sample after chemical treatment. To grant this approval, the State must determine that collecting a sample prior to chemical treatment is not...
Microbiological and meteorological analysis of two Australian dust storms in April 2009.
Lim, Natalie; Munday, Chris I; Allison, Gwen E; O'Loingsigh, Tadhg; De Deckker, Patrick; Tapper, Nigel J
2011-12-15
Dust is an important source of bioaerosols including bacteria. In this study, the microbiology and meteorology of specific dust storms in Australia were investigated. The samples were collected from two dust events in April 2009 that were characterised by intense cold fronts that entrained dust from the highly erodible and drought-stricken Mallee and Riverina regions of Victoria and central NSW. In the first storm, the dust travelled eastward over Canberra and Sydney, and in the second storm, the dust travelled east/southeastward over Canberra and Melbourne. Rain fell on both cities during the second dust storm. Dust and rain samples were collected, cultured, and the composition compared using polymerase chain reaction denaturing gradient gel electrophoresis (PCR-DGGE). Multiple bands were evident on DGGE indicative of a diverse microflora, and identification of several bands confirmed the presence of multiple genera and species representing three phyla. Numerous bands represented Bacillus species, and these were present in multiple dust samples collected from both Canberra and Melbourne. Interestingly, the microflora present in rain samples collected in Canberra during the second dust storm was quite different and the DGGE banding patterns from these samples clustered separately to most dust samples collected at the same time. Identification of several DGGE bands and PCR products from these rain samples indicated the presence of Pseudomonas species. These results indicate that Australian dust and rain have a diverse microflora and highlights the contribution of dust events to the distribution of microbes in the environment. Copyright © 2011 Elsevier B.V. All rights reserved.
Li, Han-Qing; Mei, Jian-Gang; Cao, Hong-Qin; Shao, Liang-Jing; Zhai, Yong-Ping
2017-12-01
To establish a multiple myeloma specimen bank applied for molecular biological researches and to explore the methods of specimen collection, transportation, storage, quality control and the management of specimen bank. Bone marrow and blood samples were collected from multiple myeloma patients, plasma cell sorting were operated after the separation of mononuclear cells from bone marrow specimens. The plasma cells were divided into 2 parts, one was added with proper amount of TRIzol and then kept in -80 °C refrigerator for subsequent RNA extraction, the other was added with proper amount of calf serum cell frozen liquid and then kept in -80 °C refrigerator for subsequent cryopreservation of DNA extraction after numbered respectively. Serum and plasma were separated from peripheral blood, specimens of serum and plasma were then stored at -80 °C refrigerator after registration. Meantime, the myeloma specimen information management system was established, managed and maintained by specially-assigned persons and continuous modification and improvement in the process of use as to facilitate the rapid collection, management, query of the effective samples and clinical data. A total of 244 portions plasma cells, 564 portions of serum, and 1005 portions of plasma were collected, clinical characters were documented. A multiple myeloma specimen bank have been established initially, which can provide quality samples and related clinical information for molecular biological research on multiple myeloma.
NASA Astrophysics Data System (ADS)
Gupta, Sakshi; Ahmad, Azeem; Gambhir, Vijayeta; Reddy, Martha N.; Mehta, Dalip S.
2015-08-01
In a typical Raman based sensor, a single laser beam is used for exciting the sample and the backscattered or forward scattered light is collected using collection optics and is analyzed by a spectrometer. We have investigated that by means of exciting the sample with multiple beams, i.e., by dividing the same input power of the single beam into two or three or more beams and exciting the sample from different angles, the Raman signal enhances significantly. Due to the presence of multiple beams passing through the same volume of the sample, an interference pattern is formed and the volume of interaction of excitation beams with the sample increases. By means of this geometry, the enhancement in the Raman signal is observed and it was found that the signal strength increases linearly with the increase in number of excitation beams. Experimental results of this scheme for excitation of the samples are reported for explosive detection at a standoff distance.
Soil Gas Sample Handling: Evaluation of Water Removal and Sample Ganging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fritz, Brad G.; Abrecht, David G.; Hayes, James C.
2016-10-31
Soil gas sampling is currently conducted in support of Nuclear Test Ban treaty verification. Soil gas samples are collected and analyzed for isotopes of interest. Some issues that can impact sampling and analysis of these samples are excess moisture and sample processing time. Here we discuss three potential improvements to the current sampling protocol; a desiccant for water removal, use of molecular sieve to remove CO 2 from the sample during collection, and a ganging manifold to allow composite analysis of multiple samples.
Offline solid phase microextraction sampling system
Harvey, Chris A.
2008-12-16
An offline solid phase microextraction (SPME) sampling apparatus for enabling SPME samples to be taken a number of times from a previously collected fluid sample (e.g. sample atmosphere) stored in a fused silica lined bottle which keeps volatile organics in the fluid sample stable for weeks at a time. The offline SPME sampling apparatus has a hollow body surrounding a sampling chamber, with multiple ports through which a portion of a previously collected fluid sample may be (a) released into the sampling chamber, (b) SPME sampled to collect analytes for subsequent GC analysis, and (c) flushed/purged using a fluidically connected vacuum source and purging fluid source to prepare the sampling chamber for additional SPME samplings of the same original fluid sample, such as may have been collected in situ from a headspace.
USDA-ARS?s Scientific Manuscript database
The effect of sponge sample collection site on the recovery of multiple indicator organisms from beef carcass surfaces was evaluated. Two 4,000 cm2 samples were collected from pre-evisceration carcasses (n=248), one from the inside and outside round area (top site) and one from the navel-plate-bris...
High-density grids for efficient data collection from multiple crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baxter, Elizabeth L.; Aguila, Laura; Alonso-Mori, Roberto
Higher throughput methods to mount and collect data from multiple small and radiation-sensitive crystals are important to support challenging structural investigations using microfocus synchrotron beamlines. Furthermore, efficient sample-delivery methods are essential to carry out productive femtosecond crystallography experiments at X-ray free-electron laser (XFEL) sources such as the Linac Coherent Light Source (LCLS). To address these needs, a high-density sample grid useful as a scaffold for both crystal growth and diffraction data collection has been developed and utilized for efficient goniometer-based sample delivery at synchrotron and XFEL sources. A single grid contains 75 mounting ports and fits inside an SSRL cassettemore » or uni-puck storage container. The use of grids with an SSRL cassette expands the cassette capacity up to 7200 samples. Grids may also be covered with a polymer film or sleeve for efficient room-temperature data collection from multiple samples. New automated routines have been incorporated into theBlu-Ice/DCSSexperimental control system to support grids, including semi-automated grid alignment, fully automated positioning of grid ports, rastering and automated data collection. Specialized tools have been developed to support crystallization experiments on grids, including a universal adaptor, which allows grids to be filled by commercial liquid-handling robots, as well as incubation chambers, which support vapor-diffusion and lipidic cubic phase crystallization experiments. Experiments in which crystals were loaded into grids or grown on grids using liquid-handling robots and incubation chambers are described. As a result, crystals were screened at LCLS-XPP and SSRL BL12-2 at room temperature and cryogenic temperatures.« less
High-density grids for efficient data collection from multiple crystals
Baxter, Elizabeth L.; Aguila, Laura; Alonso-Mori, Roberto; Barnes, Christopher O.; Bonagura, Christopher A.; Brehmer, Winnie; Brunger, Axel T.; Calero, Guillermo; Caradoc-Davies, Tom T.; Chatterjee, Ruchira; Degrado, William F.; Fraser, James S.; Ibrahim, Mohamed; Kern, Jan; Kobilka, Brian K.; Kruse, Andrew C.; Larsson, Karl M.; Lemke, Heinrik T.; Lyubimov, Artem Y.; Manglik, Aashish; McPhillips, Scott E.; Norgren, Erik; Pang, Siew S.; Soltis, S. M.; Song, Jinhu; Thomaston, Jessica; Tsai, Yingssu; Weis, William I.; Woldeyes, Rahel A.; Yachandra, Vittal; Yano, Junko; Zouni, Athina; Cohen, Aina E.
2016-01-01
Higher throughput methods to mount and collect data from multiple small and radiation-sensitive crystals are important to support challenging structural investigations using microfocus synchrotron beamlines. Furthermore, efficient sample-delivery methods are essential to carry out productive femtosecond crystallography experiments at X-ray free-electron laser (XFEL) sources such as the Linac Coherent Light Source (LCLS). To address these needs, a high-density sample grid useful as a scaffold for both crystal growth and diffraction data collection has been developed and utilized for efficient goniometer-based sample delivery at synchrotron and XFEL sources. A single grid contains 75 mounting ports and fits inside an SSRL cassette or uni-puck storage container. The use of grids with an SSRL cassette expands the cassette capacity up to 7200 samples. Grids may also be covered with a polymer film or sleeve for efficient room-temperature data collection from multiple samples. New automated routines have been incorporated into the Blu-Ice/DCSS experimental control system to support grids, including semi-automated grid alignment, fully automated positioning of grid ports, rastering and automated data collection. Specialized tools have been developed to support crystallization experiments on grids, including a universal adaptor, which allows grids to be filled by commercial liquid-handling robots, as well as incubation chambers, which support vapor-diffusion and lipidic cubic phase crystallization experiments. Experiments in which crystals were loaded into grids or grown on grids using liquid-handling robots and incubation chambers are described. Crystals were screened at LCLS-XPP and SSRL BL12-2 at room temperature and cryogenic temperatures. PMID:26894529
High-density grids for efficient data collection from multiple crystals
Baxter, Elizabeth L.; Aguila, Laura; Alonso-Mori, Roberto; ...
2015-11-03
Higher throughput methods to mount and collect data from multiple small and radiation-sensitive crystals are important to support challenging structural investigations using microfocus synchrotron beamlines. Furthermore, efficient sample-delivery methods are essential to carry out productive femtosecond crystallography experiments at X-ray free-electron laser (XFEL) sources such as the Linac Coherent Light Source (LCLS). To address these needs, a high-density sample grid useful as a scaffold for both crystal growth and diffraction data collection has been developed and utilized for efficient goniometer-based sample delivery at synchrotron and XFEL sources. A single grid contains 75 mounting ports and fits inside an SSRL cassettemore » or uni-puck storage container. The use of grids with an SSRL cassette expands the cassette capacity up to 7200 samples. Grids may also be covered with a polymer film or sleeve for efficient room-temperature data collection from multiple samples. New automated routines have been incorporated into theBlu-Ice/DCSSexperimental control system to support grids, including semi-automated grid alignment, fully automated positioning of grid ports, rastering and automated data collection. Specialized tools have been developed to support crystallization experiments on grids, including a universal adaptor, which allows grids to be filled by commercial liquid-handling robots, as well as incubation chambers, which support vapor-diffusion and lipidic cubic phase crystallization experiments. Experiments in which crystals were loaded into grids or grown on grids using liquid-handling robots and incubation chambers are described. As a result, crystals were screened at LCLS-XPP and SSRL BL12-2 at room temperature and cryogenic temperatures.« less
Karger, Barry L.; Kotler, Lev; Foret, Frantisek; Minarik, Marek; Kleparnik, Karel
2003-12-09
A modular multiple lane or capillary electrophoresis (chromatography) system that permits automated parallel separation and comprehensive collection of all fractions from samples in all lanes or columns, with the option of further on-line automated sample fraction analysis, is disclosed. Preferably, fractions are collected in a multi-well fraction collection unit, or plate (40). The multi-well collection plate (40) is preferably made of a solvent permeable gel, most preferably a hydrophilic, polymeric gel such as agarose or cross-linked polyacrylamide.
Chambers, Andrew G.; Percy, Andrew J.; Yang, Juncong; Camenzind, Alexander G.; Borchers, Christoph H.
2013-01-01
Dried blood spot (DBS) sampling, coupled with multiple reaction monitoring mass spectrometry (MRM-MS), is a well-established approach for quantifying a wide range of small molecule biomarkers and drugs. This sampling procedure is simpler and less-invasive than those required for traditional plasma or serum samples enabling collection by minimally trained personnel. Many analytes are stable in the DBS format without refrigeration, which reduces the cost and logistical challenges of sample collection in remote locations. These advantages make DBS sample collection desirable for advancing personalized medicine through population-wide biomarker screening. Here we expand this technology by demonstrating the first multiplexed method for the quantitation of endogenous proteins in DBS samples. A panel of 60 abundant proteins in human blood was targeted by monitoring proteotypic tryptic peptides and their stable isotope-labeled analogs by MRM. Linear calibration curves were obtained for 40 of the 65 peptide targets demonstrating multiple proteins can be quantitatively extracted from DBS collection cards. The method was also highly reproducible with a coefficient of variation of <15% for all 40 peptides. Overall, this assay quantified 37 proteins spanning a range of more than four orders of magnitude in concentration within a single 25 min LC/MRM-MS analysis. The protein abundances of the 33 proteins quantified in matching DBS and whole blood samples showed an excellent correlation, with a slope of 0.96 and an R2 value of 0.97. Furthermore, the measured concentrations for 80% of the proteins were stable for at least 10 days when stored at −20 °C, 4 °C and 37 °C. This work represents an important first step in evaluating the integration of DBS sampling with highly-multiplexed MRM for quantitation of endogenous proteins. PMID:23221968
H. T. Schreuder; M. S. Williams; C. Aguirre-Bravo; P. L. Patterson
2003-01-01
The sampling strategy is presented for the initial phase of the natural resources pilot project in the Mexican States of Jalisco and Colima. The sampling design used is ground-based cluster sampling with poststratification based on Landsat Thematic Mapper imagery. The data collected will serve as a basis for additional data collection, mapping, and spatial modeling...
Fashion, Paper Dolls and Multiplicatives
ERIC Educational Resources Information Center
Ura, Suzana Kaori; Stein-Barana, Alzira C. M.; Munhoz, Deisy P.
2011-01-01
The multiplicative principle is the tool allowing the counting of groups that can be described by a sequence of events. An event is a subset of sample space, i.e. a collection of possible outcomes, which may be equal to or smaller than the sample space as a whole. It is important that students understand this basic principle early on and know how…
Survival and multiplication of Legionella pneumophila in municipal drinking water systems.
States, S J; Conley, L F; Kuchta, J M; Oleck, B M; Lipovich, M J; Wolford, R S; Wadowsky, R M; McNamara, A M; Sykora, J L; Keleti, G
1987-01-01
Studies were conducted to investigate the survival and multiplication of Legionella spp. in public drinking water supplies. An attempt was made, over a period of several years, to isolate legionellae from a municipal system. Sampling sites included the river water supply, treatment plant, finished water reservoir system, mains, and distribution taps. Despite the use of several isolation techniques, Legionella spp. could not be detected in any of the samples other than those collected from the river. It was hypothesized that this was due to the maintenance of a chlorine residual throughout the system. To investigate the potential for Legionella growth, additional water samples, collected from throughout the system, were dechlorinated, pasteurized, and inoculated with Legionella pneumophila. Subsequent growth indicated that many of these samples, especially those collected from areas affected by an accumulation of algal materials, exhibited a much greater ability to support Legionella multiplication than did river water prior to treatment. Chemical analyses were also performed on these samples. Correlation of chemical data and experimental growth results indicated that the chemical environment significantly affects the ability of the water to support multiplication, with turbidity, organic carbon, and certain metals being of particular importance. These studies indicate that the potential exists for Legionella growth within municipal systems and support the hypothesis that public water supplies may contaminate the plumbing systems of hospitals and other large buildings. The results also suggest that useful methods to control this contamination include adequate treatment plant filtration, maintenance of a chlorine residual throughout the treatment and distribution network, and effective covering of open reservoirs. PMID:3606101
Molecular dynamics based enhanced sampling of collective variables with very large time steps.
Chen, Pei-Yang; Tuckerman, Mark E
2018-01-14
Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.
Molecular dynamics based enhanced sampling of collective variables with very large time steps
NASA Astrophysics Data System (ADS)
Chen, Pei-Yang; Tuckerman, Mark E.
2018-01-01
Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.
PBDES IN US HUMANS, FOOD, AND ENVIRONMENTAL SAMPLES
Polybrominated diphenyl ether (PBDE) flame retardants were measured in US human milk and blood, food and environmental samples. All 59 milk samples were positive for multiple congeners measured. Milk was collected beginning in 2001 from various locations in the US. PBDEs varied f...
Clark, Dennis A.; Izbicki, John A.; Metzger, Loren F.; Everett, Rhett; Smith, Gregory A.; O'Leary, David R.; Teague, Nicholas F.; Burgess, Matthew K.
2012-01-01
Data were collected by the U.S. Geological Survey from 2003 through 2008 in the Eastern San Joaquin Groundwater Subbasin, 80 miles east of San Francisco, California, as part of a study of the increasing chloride concentrations in groundwater processes. Data collected include geologic, geophysical, chemical, and hydrologic data collected during and after the installation of five multiple-well monitoring sites, from three existing multiple-well sites, and from 79 selected public-supply, irrigation, and domestic wells. Each multiple-well monitoring site installed as part of this study contained three to five 2-inch diameter polyvinyl chloride (PVC)-cased wells ranging in depth from 68 to 880 feet below land surface. Continuous water-level data were collected from the 19 wells installed at these 5 sites and from 10 existing monitoring wells at 3 additional multiple-well sites in the study area. Thirty-one electromagnetic logs were collected seasonally from the deepest PVC-cased monitoring well at seven multiple-well sites. About 200 water samples were collected from 79 wells in the study area. Coupled well-bore flow data and depth-dependent water-quality data were collected from 12 production wells under pumped conditions, and well-bore flow data were collected from 10 additional wells under unpumped conditions.
NASA Astrophysics Data System (ADS)
Isnard, H.; Aubert, M.; Blanchet, P.; Brennetot, R.; Chartier, F.; Geertsen, V.; Manuguerra, F.
2006-02-01
Strontium-90 is one of the most important fission products generated in nuclear industry. In the research field concerning nuclear waste disposal in deep geological environment, it is necessary to quantify accurately and precisely its concentration (or the 90Sr / 238U atomic ratio) in irradiated fuels. To obtain accurate analysis of radioactive 90Sr, mass spectrometry associated with isotope dilution is the most appropriated method. But, in nuclear fuel samples the interference with 90Zr must be previously eliminated. An inductively coupled plasma mass spectrometer with multiple collection, equipped with an hexapole collision cell, has been used to eliminate the 90Sr / 90Zr interference by addition of oxygen in the collision cell as a reactant gas. Zr + ions are converted into ZrO +, whereas Sr + ions are not reactive. A mixed solution, prepared from a solution of enriched 84Sr and a solution of enriched 235U was then used to quantify the 90Sr / 238U ratio in spent fuel sample solutions using the double isotope dilution method. This paper shows the results, the reproducibility and the uncertainties that can be obtained with this method to quantify the 90Sr / 238U atomic ratio in an UOX (uranium oxide) and a MOX (mixed oxide) spent fuel samples using the collision cell of an inductively coupled plasma mass spectrometer with multiple collection to perform the 90Sr / 90Zr separation. A comparison with the results obtained by inductively coupled plasma mass spectrometer with multiple collection after a chemical separation of strontium from zirconium using a Sr spec resin (Eichrom) has been performed. Finally, to validate the analytical procedure developed, measurements of the same samples have been performed by thermal ionization mass spectrometry, used as an independent technique, after chemical separation of Sr.
Armstrong, Jenna L; Fitzpatrick, Cole F; Loftus, Christine T; Yost, Michael G; Tchong-French, Maria; Karr, Catherine J
2013-09-01
This research describes the design, deployment, performance, and acceptability of a novel outdoor active air sampler to provide simultaneous measurements of multiple contaminants at timed intervals for the Aggravating Factors of Asthma in Rural Environment (AFARE) study-a longitudinal cohort of 50 children in Yakima Valley, Washington. The sampler was constructed of multiple sampling media connected to individual critical orifices and a rotary vane vacuum pump. It was connected to a timed control valve system to collect 24 hours samples every six days over 18 months. We describe a spatially representative approach with both quantitative and qualitative location criteria to deploy a network of 14 devices at participant residences in a rural region (20 × 60 km). Overall the sampler performed well, as the concurrent mean sample flow rates were within or above the ranges of recommended sampling rates for each exposure metric of interest. Acceptability was high among the study population of Hispanic farmworker participant households. The sampler design may prove useful for future urban and rural community-based studies with aims at collecting multiple contaminant data during specific time periods.
On sampling biases arising from insufficient bottle flushing
NASA Astrophysics Data System (ADS)
Codispoti, L. A.; Paver, C. R.
2016-02-01
Collection of representative water samples using carousel bottles is important for accurately determining biological and chemical gradients. The development of more technologically advanced instrumentation and sampling apparatus causes sampling packages to increase and "soak times" to decrease, increasing the probability that insufficient bottle flushing will produce biased results. Qualitative evidence from various expeditions suggest that insufficient flushing may be a problem. Here we report on multiple field experiments that were conducted to better quantify the errors that can arise from insufficient bottle flushing. Our experiments suggest that soak times of more than 2 minutes are sometimes required to collect a representative sample.
Steele, Riley E; Nasser, Nawaf A; Patterson, R Timothy; Gregory, Braden R B; Roe, Helen M; Reinhardt, Eduard G
2018-03-04
Arcellinida (testate lobose amoebae), a group of benthic protists, were examined from 46 sediment-water interface samples collected from oligotrophic Oromocto Lake, New Brunswick, Canada. To assess (1) assemblage homogeneity at a sub-meter spatial scale and (2) the necessity for collecting samples from multiple stations during intra-lake surveys; multiple samples were collected from three stations (quadrats 1, 2, and 3) across the north basin of Oromocto Lake, with quadrat 1 (n = 16) being the furthest to the west, quadrat 2 (n = 15) situated closer to the center of the basin, and quadrat 3 (n = 15) positioned 300 m south of the mouth of Dead Brook, an inlet stream. Results from cluster analysis and non-metric multidimensional scaling (NMDS) analysis identified two major Arcellinida assemblages, A1 and A2, the latter containing two sub-assemblages (A2a and A2b). Redundancy analysis and variance partitioning results indicated that seven statistically significant environmental variables (K, S, Sb, Ti, Zn, Fe, and Mn) explained 41.5% of the total variation in the Arcellinida distribution. Iron, Ti and K, indicators of detrital runoff, had the greatest influence on assemblage variance. The results of this study reveal that closely spaced samples (~ 10 cm) in an open-water setting are comprised of homogenous arcellinidan assemblages, indicating that replicate sampling is not required. The results, however, must be tempered with respect to the various water properties and physical characteristics that comprise individual lakes as collection of several samples may likely be necessary when sampling multiple sites of a lake basin characterized by varying water depths (e.g., littoral zone vs. open water), or lakes impacted by geogenic or anthropogenic stressors (e.g., eutrophication, or industrial contamination).
Flagging versus dragging as sampling methods for nymphal Ixodes scapularis (Acari: Ixodidae)
Rulison, Eric L.; Kuczaj, Isis; Pang, Genevieve; Hickling, Graham J.; Tsao, Jean I.; Ginsberg, Howard S.
2013-01-01
The nymphal stage of the blacklegged tick, Ixodes scapularis (Acari: Ixodidae), is responsible for most transmission of Borrelia burgdorferi, the etiologic agent of Lyme disease, to humans in North America. From 2010 to fall of 2012, we compared two commonly used techniques, flagging and dragging, as sampling methods for nymphal I. scapularis at three sites, each with multiple sampling arrays (grids), in the eastern and central United States. Flagging and dragging collected comparable numbers of nymphs, with no consistent differences between methods. Dragging collected more nymphs than flagging in some samples, but these differences were not consistent among sites or sampling years. The ratio of nymphs collected by flagging vs dragging was not significantly related to shrub density, so habitat type did not have a strong effect on the relative efficacy of these methods. Therefore, although dragging collected more ticks in a few cases, the numbers collected by each method were so variable that neither technique had a clear advantage for sampling nymphal I. scapularis.
Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi
2016-02-01
Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62 mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.
Hotspot and sampling analysis for effective maintenance and performance monitoring.
DOT National Transportation Integrated Search
2017-05-01
In this project, we propose two sampling methods addressing how much and where the agencies need to collect infrastraucture condition data for accurate Level-of-Maintenance (LOM) estimation in maintenance network with single type or multiple ty...
Baker, Laurie L; Mills Flemming, Joanna E; Jonsen, Ian D; Lidgard, Damian C; Iverson, Sara J; Bowen, W Don
2015-01-01
Paired with satellite location telemetry, animal-borne instruments can collect spatiotemporal data describing the animal's movement and environment at a scale relevant to its behavior. Ecologists have developed methods for identifying the area(s) used by an animal (e.g., home range) and those used most intensely (utilization distribution) based on location data. However, few have extended these models beyond their traditional roles as descriptive 2D summaries of point data. Here we demonstrate how the home range method, T-LoCoH, can be expanded to quantify collective sampling coverage by multiple instrumented animals using grey seals (Halichoerus grypus) equipped with GPS tags and acoustic transceivers on the Scotian Shelf (Atlantic Canada) as a case study. At the individual level, we illustrate how time and space-use metrics quantifying individual sampling coverage may be used to determine the rate of acoustic transmissions received. Grey seals collectively sampled an area of 11,308 km (2) and intensely sampled an area of 31 km (2) from June-December. The largest area sampled was in July (2094.56 km (2)) and the smallest area sampled occurred in August (1259.80 km (2)), with changes in sampling coverage observed through time. T-LoCoH provides an effective means to quantify changes in collective sampling effort by multiple instrumented animals and to compare these changes across time. We also illustrate how time and space-use metrics of individual instrumented seal movement calculated using T-LoCoH can be used to account for differences in the amount of time a bioprobe (biological sampling platform) spends in an area.
DICARBOXYLIC ACID CONCENTRATION TRENDS AND SAMPLING ARTIFACTS
Dicarboxylic acids associated with airborne particulate matter were measured during a summer period in Philadelphia that included multiple air pollution episodes. Samples were collected for two ten hour periods each day using a high volume sampler with two quartz fiber filters in...
Al, Kait F; Bisanz, Jordan E; Gloor, Gregory B; Reid, Gregor; Burton, Jeremy P
2018-01-01
The increasing interest on the impact of the gut microbiota on health and disease has resulted in multiple human microbiome-related studies emerging. However, multiple sampling methods are being used, making cross-comparison of results difficult. To avoid additional clinic visits and increase patient recruitment to these studies, there is the potential to utilize at-home stool sampling. The aim of this pilot study was to compare simple self-sampling collection and storage methods. To simulate storage conditions, stool samples from three volunteers were freshly collected, placed on toilet tissue, and stored at four temperatures (-80, 7, 22 and 37°C), either dry or in the presence of a stabilization agent (RNAlater®) for 3 or 7days. Using 16S rRNA gene sequencing by Illumina, the effect of storage variations for each sample was compared to a reference community from fresh, unstored counterparts. Fastq files may be accessed in the NCBI Sequence Read Archive: Bioproject ID PRJNA418287. Microbial diversity and composition were not significantly altered by any storage method. Samples were always separable based on participant, regardless of storage method suggesting there was no need for sample preservation by a stabilization agent. In summary, if immediate sample processing is not feasible, short term storage of unpreserved stool samples on toilet paper offers a reliable way to assess the microbiota composition by 16S rRNA gene sequencing. Copyright © 2017 Elsevier B.V. All rights reserved.
Adaptive Sampling-Based Information Collection for Wireless Body Area Networks.
Xu, Xiaobin; Zhao, Fang; Wang, Wendong; Tian, Hui
2016-08-31
To collect important health information, WBAN applications typically sense data at a high frequency. However, limited by the quality of wireless link, the uploading of sensed data has an upper frequency. To reduce upload frequency, most of the existing WBAN data collection approaches collect data with a tolerable error. These approaches can guarantee precision of the collected data, but they are not able to ensure that the upload frequency is within the upper frequency. Some traditional sampling based approaches can control upload frequency directly, however, they usually have a high loss of information. Since the core task of WBAN applications is to collect health information, this paper aims to collect optimized information under the limitation of upload frequency. The importance of sensed data is defined according to information theory for the first time. Information-aware adaptive sampling is proposed to collect uniformly distributed data. Then we propose Adaptive Sampling-based Information Collection (ASIC) which consists of two algorithms. An adaptive sampling probability algorithm is proposed to compute sampling probabilities of different sensed values. A multiple uniform sampling algorithm provides uniform samplings for values in different intervals. Experiments based on a real dataset show that the proposed approach has higher performance in terms of data coverage and information quantity. The parameter analysis shows the optimized parameter settings and the discussion shows the underlying reason of high performance in the proposed approach.
Adaptive Sampling-Based Information Collection for Wireless Body Area Networks
Xu, Xiaobin; Zhao, Fang; Wang, Wendong; Tian, Hui
2016-01-01
To collect important health information, WBAN applications typically sense data at a high frequency. However, limited by the quality of wireless link, the uploading of sensed data has an upper frequency. To reduce upload frequency, most of the existing WBAN data collection approaches collect data with a tolerable error. These approaches can guarantee precision of the collected data, but they are not able to ensure that the upload frequency is within the upper frequency. Some traditional sampling based approaches can control upload frequency directly, however, they usually have a high loss of information. Since the core task of WBAN applications is to collect health information, this paper aims to collect optimized information under the limitation of upload frequency. The importance of sensed data is defined according to information theory for the first time. Information-aware adaptive sampling is proposed to collect uniformly distributed data. Then we propose Adaptive Sampling-based Information Collection (ASIC) which consists of two algorithms. An adaptive sampling probability algorithm is proposed to compute sampling probabilities of different sensed values. A multiple uniform sampling algorithm provides uniform samplings for values in different intervals. Experiments based on a real dataset show that the proposed approach has higher performance in terms of data coverage and information quantity. The parameter analysis shows the optimized parameter settings and the discussion shows the underlying reason of high performance in the proposed approach. PMID:27589758
Pothineni, Sudhir Babu; Venugopalan, Nagarajan; Ogata, Craig M.; Hilgart, Mark C.; Stepanov, Sergey; Sanishvili, Ruslan; Becker, Michael; Winter, Graeme; Sauter, Nicholas K.; Smith, Janet L.; Fischetti, Robert F.
2014-01-01
The calculation of single- and multi-crystal data collection strategies and a data processing pipeline have been tightly integrated into the macromolecular crystallographic data acquisition and beamline control software JBluIce. Both tasks employ wrapper scripts around existing crystallographic software. JBluIce executes scripts through a distributed resource management system to make efficient use of all available computing resources through parallel processing. The JBluIce single-crystal data collection strategy feature uses a choice of strategy programs to help users rank sample crystals and collect data. The strategy results can be conveniently exported to a data collection run. The JBluIce multi-crystal strategy feature calculates a collection strategy to optimize coverage of reciprocal space in cases where incomplete data are available from previous samples. The JBluIce data processing runs simultaneously with data collection using a choice of data reduction wrappers for integration and scaling of newly collected data, with an option for merging with pre-existing data. Data are processed separately if collected from multiple sites on a crystal or from multiple crystals, then scaled and merged. Results from all strategy and processing calculations are displayed in relevant tabs of JBluIce. PMID:25484844
Pothineni, Sudhir Babu; Venugopalan, Nagarajan; Ogata, Craig M.; ...
2014-11-18
The calculation of single- and multi-crystal data collection strategies and a data processing pipeline have been tightly integrated into the macromolecular crystallographic data acquisition and beamline control software JBluIce. Both tasks employ wrapper scripts around existing crystallographic software. JBluIce executes scripts through a distributed resource management system to make efficient use of all available computing resources through parallel processing. The JBluIce single-crystal data collection strategy feature uses a choice of strategy programs to help users rank sample crystals and collect data. The strategy results can be conveniently exported to a data collection run. The JBluIce multi-crystal strategy feature calculates amore » collection strategy to optimize coverage of reciprocal space in cases where incomplete data are available from previous samples. The JBluIce data processing runs simultaneously with data collection using a choice of data reduction wrappers for integration and scaling of newly collected data, with an option for merging with pre-existing data. Data are processed separately if collected from multiple sites on a crystal or from multiple crystals, then scaled and merged. Results from all strategy and processing calculations are displayed in relevant tabs of JBluIce.« less
Wildlife monitoring across multiple spatial scales using grid-based sampling
Kevin S. McKelvey; Samuel A. Cushman; Michael K. Schwartz; Leonard F. Ruggiero
2009-01-01
Recently, noninvasive genetic sampling has become the most effective way to reliably sample occurrence of many species. In addition, genetic data provide a rich data source enabling the monitoring of population status. The combination of genetically based animal data collected at known spatial coordinates with vegetation, topography, and other available covariates...
Witt, Emitt C; Wronkiewicz, David J; Shi, Honglan
2013-01-01
Fugitive road dust collection for chemical analysis and interpretation has been limited by the quantity and representativeness of samples. Traditional methods of fugitive dust collection generally focus on point-collections that limit data interpretation to a small area or require the investigator to make gross assumptions about the origin of the sample collected. These collection methods often produce a limited quantity of sample that may hinder efforts to characterize the samples by multiple geochemical techniques, preserve a reference archive, and provide a spatially integrated characterization of the road dust health hazard. To achieve a "better sampling" for fugitive road dust studies, a cyclonic fugitive dust (CFD) sampler was constructed and tested. Through repeated and identical sample collection routes at two collection heights (50.8 and 88.9 cm above the road surface), the products of the CFD sampler were characterized using particle size and chemical analysis. The average particle size collected by the cyclone was 17.9 μm, whereas particles collected by a secondary filter were 0.625 μm. No significant difference was observed between the two sample heights tested and duplicates collected at the same height; however, greater sample quantity was achieved at 50.8 cm above the road surface than at 88.9 cm. The cyclone effectively removed 94% of the particles >1 μm, which substantially reduced the loading on the secondary filter used to collect the finer particles; therefore, suction is maintained for longer periods of time, allowing for an average sample collection rate of about 2 g mi. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Melcher, Anthony A; Horsburgh, Jeffery S
2017-06-01
Water quality in urban streams and stormwater systems is highly dynamic, both spatially and temporally, and can change drastically during storm events. Infrequent grab samples commonly collected for estimating pollutant loadings are insufficient to characterize water quality in many urban water systems. In situ water quality measurements are being used as surrogates for continuous pollutant load estimates; however, relatively few studies have tested the validity of surrogate indicators in urban stormwater conveyances. In this paper, we describe an observatory aimed at demonstrating the infrastructure required for surrogate monitoring in urban water systems and for capturing the dynamic behavior of stormwater-driven pollutant loads. We describe the instrumentation of multiple, autonomous water quality and quantity monitoring sites within an urban observatory. We also describe smart and adaptive sampling procedures implemented to improve data collection for developing surrogate relationships and for capturing the temporal and spatial variability of pollutant loading events in urban watersheds. Results show that the observatory is able to capture short-duration storm events within multiple catchments and, through inter-site communication, sampling efforts can be synchronized across multiple monitoring sites.
Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C
2015-12-01
Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.
USDA-ARS?s Scientific Manuscript database
Background/Question/Methods Standardized monitoring data collection efforts using a probabilistic sample design, such as in the Bureau of Land Management’s (BLM) Assessment, Inventory, and Monitoring (AIM) Strategy, provide a core suite of ecological indicators, maximize data collection efficiency,...
USDA-ARS?s Scientific Manuscript database
Standardized monitoring data collection efforts using a probabilistic sample design, such as in the Bureau of Land Management’s (BLM) Assessment, Inventory, and Monitoring (AIM) Strategy, provide a core suite of ecological indicators, maximize data collection efficiency, and promote reuse of monitor...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yi-Xin; Zeng, Qiang; Wang, Le
Urinary haloacetic acids (HAAs), such as dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA), have been suggested as potential biomarkers of exposure to drinking water disinfection byproducts (DBPs). However, variable exposure to and the short elimination half-lives of these biomarkers can result in considerable variability in urinary measurements, leading to exposure misclassification. Here we examined the variability of DCAA and TCAA levels in the urine among eleven men who provided urine samples on 8 days over 3 months. The urinary concentrations of DCAA and TCAA were measured by gas chromatography coupled with electron capture detection. We calculated the intraclass correlation coefficientsmore » (ICCs) to characterize the within-person and between-person variances and computed the sensitivity and specificity to assess how well single or multiple urine collections accurately determined personal 3-month average DCAA and TCAA levels. The within-person variance was much higher than the between-person variance for all three sample types (spot, first morning, and 24-h urine samples) for DCAA (ICC=0.08–0.37) and TCAA (ICC=0.09–0.23), regardless of the sampling interval. A single-spot urinary sample predicted high (top 33%) 3-month average DCAA and TCAA levels with high specificity (0.79 and 0.78, respectively) but relatively low sensitivity (0.47 and 0.50, respectively). Collecting two or three urine samples from each participant improved the classification. The poor reproducibility of the measured urinary DCAA and TCAA concentrations indicate that a single measurement may not accurately reflect individual long-term exposure. Collection of multiple urine samples from one person is an option for reducing exposure classification errors in studies exploring the effects of DBP exposure on reproductive health. - Highlights: • We evaluated the variability of DCAA and TCAA levels in the urine among men. • Urinary DCAA and TCAA levels varied greatly over a 3-month period. • Single measurement may not accurately reflect personal long-term exposure levels. • Collecting multiple samples from one person improved the exposure classification.« less
Tissue, Blood, and Body Fluid Sample Collection From Patients With Hematologic Cancer
2017-09-20
Chronic Myeloproliferative Disorders; Leukemia; Lymphoma; Lymphoproliferative Disorder; Multiple Myeloma and Plasma Cell Neoplasm; Myelodysplastic Syndromes; Myelodysplastic/Myeloproliferative Neoplasms; Nonmalignant Neoplasm
McAdoo, Mitchell A.; Kozar, Mark D.
2017-11-14
This report describes a compilation of existing water-quality data associated with groundwater resources originating from abandoned underground coal mines in West Virginia. Data were compiled from multiple sources for the purpose of understanding the suitability of groundwater from abandoned underground coal mines for public supply, industrial, agricultural, and other uses. This compilation includes data collected for multiple individual studies conducted from July 13, 1973 through September 7, 2016. Analytical methods varied by the time period of data collection and requirements of the independent studies.This project identified 770 water-quality samples from 294 sites that could be attributed to abandoned underground coal mine aquifers originating from multiple coal seams in West Virginia.
A precision multi-sampler for deep-sea hydrothermal microbial mat studies
NASA Astrophysics Data System (ADS)
Breier, J. A.; Gomez-Ibanez, D.; Reddington, E.; Huber, J. A.; Emerson, D.
2012-12-01
A new tool was developed for deep-sea microbial mat studies by remotely operated vehicles and was successfully deployed during a cruise to the hydrothermal vent systems of the Mid-Cayman Rise. The Mat Sampler allows for discrete, controlled material collection from complex microbial structures, vertical-profiling within thick microbial mats and particulate and fluid sample collection from venting seafloor fluids. It has a reconfigurable and expandable sample capacity based on magazines of 6 syringes, filters, or water bottles. Multiple magazines can be used such that 12-36 samples can be collected routinely during a single dive; several times more if the dive is dedicated for this purpose. It is capable of hosting in situ physical, electrochemical, and optical sensors, including temperature and oxygen probes in order to guide sampling and to record critical environmental parameters at the time and point of sample collection. The precision sampling capability of this instrument will greatly enhance efforts to understand the structured, delicate, microbial mat communities that grow in diverse benthic habitats.
MEASUREMENTS OF AIR POLLUTANT BIOMARKERS WITH EXHALED BREATH TECHNIQUES
Use of exhaled breath condensate (EBC) has appeal as a noninvasive surrogate sample for lung-derived fluid. Additionally, EBC can be collected multiple times over the course of a study, unlike many other lung sampling techniques which can be performed fewer times. However validat...
Multiple Smaller Missions as a Direct Pathway to Mars Sample Return
NASA Technical Reports Server (NTRS)
Niles, P. B.; Draper, D. S.; Evans, C. A.; Gibson, E. K.; Graham, L. D.; Jones, J. H.; Lederer, S. M.; Ming, D.; Seaman, C. H.; Archer, P. D.;
2012-01-01
Recent discoveries by the Mars Exploration Rovers, Mars Express, Mars Odyssey, and Mars Reconnaissance Orbiter spacecraft include multiple, tantalizing astrobiological targets representing both past and present environments on Mars. The most desirable path to Mars Sample Return (MSR) would be to collect and return samples from that site which provides the clearest examples of the variety of rock types considered a high priority for sample return (pristine igneous, sedimentary, and hydrothermal). Here we propose an MSR architecture in which the next steps (potentially launched in 2018) would entail a series of smaller missions, including caching, to multiple landing sites to verify the presence of high priority sample return targets through in situ analyses. This alternative architecture to one flagship-class sample caching mission to a single site would preserve a direct path to MSR as stipulated by the Planetary Decadal Survey, while permitting investigation of diverse deposit types and providing comparison of the site of returned samples to other aqueous environments on early Mars
Wickremsinhe, Enaksha R; Perkins, Everett J
2015-03-01
Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 μL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal-often to a single collection per mouse-thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 μL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study.
Wickremsinhe, Enaksha R; Perkins, Everett J
2015-01-01
Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 µL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal—often to a single collection per mouse—thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 µL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study. PMID:25836959
The Learning Styles and Multiple Intelligences of EFL College Students in Kuwait
ERIC Educational Resources Information Center
Alrabah, Sulaiman; Wu, Shu-hua; Alotaibi, Abdullah M.
2018-01-01
The study aimed to investigate the learning styles and multiple intelligences of English as foreign language (EFL) college-level students. "Convenience sampling" (Patton, 2015) was used to collect data from a population of 250 students enrolled in seven different academic departments at the College of Basic Education in Kuwait. The data…
USDA-ARS?s Scientific Manuscript database
Given a set of biallelic molecular markers, such as SNPs, with genotype values encoded numerically on a collection of plant, animal or human samples, the goal of genetic trait prediction is to predict the quantitative trait values by simultaneously modeling all marker effects. Genetic trait predicti...
Cesium isotope ratios as indicators of nuclear power plant operations.
Delmore, James E; Snyder, Darin C; Tranter, Troy; Mann, Nick R
2011-11-01
There are multiple paths by which radioactive cesium can reach the effluent from reactor operations. The radioactive (135)Cs/(137)Cs ratios are controlled by these paths. In an effort to better understand the origin of this radiation, these (135)Cs/(137)Cs ratios in effluents from three power reactor sites have been measured in offsite samples. These ratios are different from global fallout by up to six fold and as such cannot have a significant component from this source. A cesium ratio for a sample collected outside of the plant boundary provides integration over the operating life of the reactor. A sample collected inside the plant at any given time can be much different from this lifetime ratio. The measured cesium ratios vary significantly for the three reactors and indicate that the multiple paths have widely varying levels of contributions. There are too many ways these isotopes can fractionate to be useful for quantitative evaluations of operating parameters in an offsite sample, although it may be possible to obtain limited qualitative information for an onsite sample. Copyright © 2011 Elsevier Ltd. All rights reserved.
ELECTROFISHING DISTANCE AND NUMBER OF SPECIES COLLECTED FROM THREE RAFTABLE WESTERN RIVERS
A key issue in assessing a fish assemblage at a site is determining a sufficient sampling effort to adequately represent the species in an assemblage. Inadequate effort produces considerable noise in multiple samples at the site or under-represents the species present. Excessiv...
Hanmer, Lyn; Nicola, Edward; Bradshaw, Debbie
2017-01-01
The quality of morbidity data in multiple routine inpatient records in a sample of South African hospitals is being assessed in terms of data accuracy and completeness. Extensive modification of available data collection tools was required to make it possible to collect the required data for the study.
Large-scale atlas of microarray data reveals biological landscape of gene expression in Arabidopsis
USDA-ARS?s Scientific Manuscript database
Transcriptome datasets from thousands of samples of the model plant Arabidopsis thaliana have been collectively generated by multiple individual labs. Although integration and meta-analysis of these samples has become routine in the plant research community, it is often hampered by the lack of metad...
Petrology of the Crystalline Rocks Hosting the Santa Fe Impact Structure
NASA Technical Reports Server (NTRS)
Schrader, C. M.; Cohen, B. A.
2010-01-01
We collected samples from within the area of shatter cone occurrence and for approximately 8 kilometers (map distance) along the roadway. Our primary goal is to date the impact. Our secondary goal is to use the petrology and Ar systematics to provide further insight into size and scale of the impact. Our approach is to: Conduct a detailed petrology study to identify lithologies that share petrologic characteristics and tectonic histories but with differing degrees of shock. Obtain micro-cores of K-bearing minerals from multiple samples for Ar-40/Ar-39 analysis. Examine the Ar diffusion patterns for multiple minerals in multiple shocked and control samples. This will help us to better understand outcrop and regional scale relationships among rocks and their responses to the impact event.
ERIC Educational Resources Information Center
Kuosuwan, Bavornluck
2016-01-01
The objective of this research was to study the readiness of English communication skills of tourism employees in Bangkok for entering the ASEAN community. The scope of this research included the employees from 26 tourism companies. A sample group was determined by utilizing multiple-stage sampling. At least three samples were collected from each…
ERIC Educational Resources Information Center
Morales, Julie R.; Guerra, Nancy G.
2006-01-01
Using longitudinal data collected over 2 years on a sample of 2,745 urban elementary school children (1st-6th graders, ages 6-11 years) from economically disadvantaged communities, effects of stressful experiences within 3 contexts (school, family, neighborhood), cumulative stress, and multiple context stress on 3 indices of children's adjustment…
Rafkin, Lisa E.; Matheson, Della; Steck, Andrea K.; Yu, Liping; Henderson, Courtney; Beam, Craig A.; Boulware, David C.
2015-01-01
Abstract Background: Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot–based screening to identify islet autoantibody–positive relatives potentially eligible for inclusion in prevention trials. Materials and Methods: Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Results: Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Conclusions: Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies. PMID:26375197
Alvarez, D.A.; Stackelberg, P.E.; Petty, J.D.; Huckins, J.N.; Furlong, E.T.; Zaugg, S.D.; Meyer, M.T.
2005-01-01
Four water samples collected using standard depth and width water-column sampling methodology were compared to an innovative passive, in situ, sampler (the polar organic chemical integrative sampler or POCIS) for the detection of 96 organic wastewater-related contaminants (OWCs) in a stream that receives agricultural, municipal, and industrial wastewaters. Thirty-two OWCs were identified in POCIS extracts whereas 9-24 were identified in individual water-column samples demonstrating the utility of POCIS for identifying contaminants whose occurrence are transient or whose concentrations are below routine analytical detection limits. Overall, 10 OWCs were identified exclusively in the POCIS extracts and only six solely identified in the water-column samples, however, repetitive water samples taken using the standard method during the POCIS deployment period required multiple trips to the sampling site and an increased number of samples to store, process, and analyze. Due to the greater number of OWCs detected in the POCIS extracts as compared to individual water-column samples, the ease of performing a single deployment as compared to collecting and processing multiple water samples, the greater mass of chemical residues sequestered, and the ability to detect chemicals which dissipate quickly, the passive sampling technique offers an efficient and effective alternative for detecting OWCs in our waterways for wastewater contaminants.
Laukkanen-Ninios, R.; Ortiz Martínez, P.; Siitonen, A.; Fredriksson-Ahomaa, M.; Korkeala, H.
2013-01-01
Sporadic and epidemiologically linked Yersinia enterocolitica strains (n = 379) isolated from fecal samples from human patients, tonsil or fecal samples from pigs collected at slaughterhouses, and pork samples collected at meat stores were genotyped using multiple-locus variable-number tandem-repeat analysis (MLVA) with six loci, i.e., V2A, V4, V5, V6, V7, and V9. In total, 312 different MLVA types were found. Similar types were detected (i) in fecal samples collected from human patients over 2 to 3 consecutive years, (ii) in samples from humans and pigs, and (iii) in samples from pigs that originated from the same farms. Among porcine strains, we found farm-specific MLVA profiles. Variations in the numbers of tandem repeats from one to four for variable-number tandem-repeat (VNTR) loci V2A, V5, V6, and V7 were observed within a farm. MLVA was applicable for serotypes O:3, O:5,27, and O:9 and appeared to be a highly discriminating tool for distinguishing sporadic and outbreak-related strains. With long-term use, interpretation of the results became more challenging due to variations in more-discriminating loci, as was observed for strains originating from pig farms. Additionally, we encountered unexpectedly short V2A VNTR fragments and sequenced them. According to the sequencing results, updated guidelines for interpreting V2A VNTR results were prepared. PMID:23637293
Application of allflex conservation buffer in illumina genotyping.
de Groot, M; Ras, T; van Haeringen, W A
2016-12-01
This experiment was designed to study if liquid conservation buffer used in the novel Tissue Sampling Technology (TST) from Allflex can be used for Illumina BeadChip genotyping. Ear punches were collected from 6 bovine samples, using both the Tissue Sampling Unit (TSU) as well as the Total Tagger Universal (TTU) collection system. The stability of the liquid conservation buffer was tested by genotyping samples on Illumina BeadChips, incubated at 0, 3, 15, 24, 48, 72, 168, 336, 720 h after sample collection. Additionally, a replenishment study was designed to test how often the liquid conservation buffer could be completely replenished before a significant call rate drop could be observed. Results from the stability study showed an average call rate of 0.993 for samples collected with the TSU system and 0.953 for samples collected with the TTU system, both exceeding the inclusion threshold call rate of 0.85. As an additional control, the identity of the individual animals was confirmed using the International Society of Animal Genetics (ISAG) recommended SNP panel. The replenishment study revealed a slight drop in the sample call rate after replenishing the conservation buffer for the fourth time for the TSU as well as the TTU samples. In routine analysis, this application allows for multiple experiments to be performed on the liquid conservation buffer, while maintaining the tissue samples for future use. The data collected in this study shows that the liquid conservation buffer used in the TST system can be used for Illumina BeadChip genotyping applications.
A Study on the Perceived Risk of Surface Sample Collection Systems in Proposal Formulation
NASA Technical Reports Server (NTRS)
Sunday, Cecily M.
2012-01-01
This project compares design and proposal elements from multiple proposals and presents conclusions and recommendations for sampling systems. Contributions from this project include a list of common evaluation themes, concept and proposal-related strengths and weaknesses and ways in which self-identified risks relate the evaluation of the mission.
Charles, Isabel; Sinclair, Ian; Addison, Daniel H
2014-04-01
A new approach to the storage, processing, and interrogation of the quality data for screening samples has improved analytical throughput and confidence and enhanced the opportunities for learning from the accumulating records. The approach has entailed the design, development, and implementation of a database-oriented system, capturing information from the liquid chromatography-mass spectrometry capabilities used for assessing the integrity of samples in AstraZeneca's screening collection. A Web application has been developed to enable the visualization and interactive annotation of the analytical data, monitor the current sample queue, and report the throughput rate. Sample purity and identity are certified automatically on the chromatographic peaks of interest if predetermined thresholds are reached on key parameters. Using information extracted in parallel from the compound registration and container inventory databases, the chromatographic and spectroscopic profiles for each vessel are linked to the sample structures and storage histories. A search engine facilitates the direct comparison of results for multiple vessels of the same or similar compounds, for single vessels analyzed at different time points, or for vessels related by their origin or process flow. Access to this network of information has provided a deeper understanding of the multiple factors contributing to sample quality assurance.
Eccentricity Fluctuations Make Flow Measurable in High Multiplicity p-p Collisions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Casalderrey-Solana, Jorge; Wiedemann, Urs Achim
2010-03-12
Elliptic flow is a hallmark of collectivity in hadronic collisions. Its measurement relies on analysis techniques which require high event multiplicity and so far can only be applied to heavy ion collisions. Here, we delineate the conditions under which elliptic flow becomes measurable in the samples of high-multiplicity (dN{sub ch}/dy>=50) p-p collisions, which will soon be collected at the LHC. We observe that fluctuations in the p-p interaction region can result in a sizable spatial eccentricity even for the most central p-p collisions. Under relatively mild assumptions on the nature of such fluctuations and on the eccentricity scaling of ellipticmore » flow, we find that the resulting elliptic flow signal in high-multiplicity p-p collisions at the LHC becomes measurable with standard techniques.« less
ERIC Educational Resources Information Center
Dehghan, Mahshid; Lopez Jaramillo, Patricio; Duenas, Ruby; Anaya, Lilliam Lima; Garcia, Ronald G.; Zhang, Xiaohe; Islam, Shofiqul; Merchant, Anwar T.
2012-01-01
Objective: To validate a food frequency questionnaire (FFQ) against multiple 24-hour dietary recalls (DRs) that could be used for Colombian adults. Methods: A convenience sample of 219 individuals participated in the study. The validity of the FFQ was evaluated against multiple DRs. Four dietary recalls were collected during the year, and an FFQ…
THE SCREENING AND RANKING ALGORITHM FOR CHANGE-POINTS DETECTION IN MULTIPLE SAMPLES
Song, Chi; Min, Xiaoyi; Zhang, Heping
2016-01-01
The chromosome copy number variation (CNV) is the deviation of genomic regions from their normal copy number states, which may associate with many human diseases. Current genetic studies usually collect hundreds to thousands of samples to study the association between CNV and diseases. CNVs can be called by detecting the change-points in mean for sequences of array-based intensity measurements. Although multiple samples are of interest, the majority of the available CNV calling methods are single sample based. Only a few multiple sample methods have been proposed using scan statistics that are computationally intensive and designed toward either common or rare change-points detection. In this paper, we propose a novel multiple sample method by adaptively combining the scan statistic of the screening and ranking algorithm (SaRa), which is computationally efficient and is able to detect both common and rare change-points. We prove that asymptotically this method can find the true change-points with almost certainty and show in theory that multiple sample methods are superior to single sample methods when shared change-points are of interest. Additionally, we report extensive simulation studies to examine the performance of our proposed method. Finally, using our proposed method as well as two competing approaches, we attempt to detect CNVs in the data from the Primary Open-Angle Glaucoma Genes and Environment study, and conclude that our method is faster and requires less information while our ability to detect the CNVs is comparable or better. PMID:28090239
NASA Astrophysics Data System (ADS)
Breier, J. A.; Sheik, C. S.; Gomez-Ibanez, D.; Sayre-McCord, R. T.; Sanger, R.; Rauch, C.; Coleman, M.; Bennett, S. A.; Cron, B. R.; Li, M.; German, C. R.; Toner, B. M.; Dick, G. J.
2014-12-01
A new tool was developed for large volume sampling to facilitate marine microbiology and biogeochemical studies. It was developed for remotely operated vehicle and hydrocast deployments, and allows for rapid collection of multiple sample types from the water column and dynamic, variable environments such as rising hydrothermal plumes. It was used successfully during a cruise to the hydrothermal vent systems of the Mid-Cayman Rise. The Suspended Particulate Rosette V2 large volume multi-sampling system allows for the collection of 14 sample sets per deployment. Each sample set can include filtered material, whole (unfiltered) water, and filtrate. Suspended particulate can be collected on filters up to 142 mm in diameter and pore sizes down to 0.2 μm. Filtration is typically at flowrates of 2 L min-1. For particulate material, filtered volume is constrained only by sampling time and filter capacity, with all sample volumes recorded by digital flowmeter. The suspended particulate filter holders can be filled with preservative and sealed immediately after sample collection. Up to 2 L of whole water, filtrate, or a combination of the two, can be collected as part of each sample set. The system is constructed of plastics with titanium fasteners and nickel alloy spring loaded seals. There are no ferrous alloys in the sampling system. Individual sample lines are prefilled with filtered, deionized water prior to deployment and remain sealed unless a sample is actively being collected. This system is intended to facilitate studies concerning the relationship between marine microbiology and ocean biogeochemistry.
Liu, Chengfang; Lu, Louise; Zhang, Linxiu; Bai, Yu; Medina, Alexis; Rozelle, Scott; Smith, Darvin Scott; Zhou, Changhai; Zang, Wei
2017-09-01
Soil-transmitted helminths, or parasitic intestinal worms, are among the most prevalent and geographically widespread parasitic infections in the world. Accurate diagnosis and quantification of helminth infection are critical for informing and assessing deworming interventions. The Kato-Katz thick smear technique, the most widely used laboratory method to quantitatively assess infection prevalence and infection intensity of helminths, has often been compared with other methods. Only a few small-scale studies, however, have considered ways to improve its diagnostic sensitivity. This study, conducted among 4,985 school-age children in an area of rural China with moderate prevalence of helminth infection, examines the effect on diagnostic sensitivity of the Kato-Katz technique when two fecal samples collected over consecutive days are examined and compared with a single sample. A secondary aim was to consider cost-effectiveness by calculating an estimate of the marginal costs of obtaining an additional fecal sample. Our findings show that analysis of an additional fecal sample led to increases of 23%, 26%, and 100% for Ascaris lumbricoides, Trichuris trichiura , and hookworm prevalence, respectively. The cost of collecting a second fecal sample for our study population was approximately USD4.60 per fecal sample. Overall, the findings suggest that investing 31% more capital in fecal sample collection prevents an underestimation of prevalence by about 21%, and hence improves the diagnostic sensitivity of the Kato-Katz method. Especially in areas with light-intensity infections of soil-transmitted helminths and limited public health resources, more accurate epidemiological surveillance using multiple fecal samples will critically inform decisions regarding infection control and prevention.
Luo, Ting; Srinivasan, Usha; Ramadugu, Kirtana; Shedden, Kerby A; Neiswanger, Katherine; Trumble, Erika; Li, Jiean J; McNeil, Daniel W; Crout, Richard J; Weyant, Robert J; Marazita, Mary L; Foxman, Betsy
2016-09-15
Community profiling of the oral microbiome requires the recovery of quality sequences in order to accurately describe microbial community structure and composition. Our objective was to assess the effects of specimen collection method, storage medium, and storage conditions on the relative abundance of taxa in saliva and plaque identified using 16S rRNA genes. We also assessed short-term changes in taxon composition and relative abundance and compared the salivary and dental plaque communities in children and adults. Over a 2-week period, four successive saliva and dental plaque specimens were collected from four adults with no dental decay (108 samples), and two successive specimens were collected from six children with four or more erupted teeth (48 samples). There were minimal differences in community composition at the phylum and operational taxonomic unit levels between dental plaque collection using a scaler and collection using a CytoSoft brush. Plaque samples stored in OMNIgene medium showed higher within-sample Shannon diversity, were compositionally different, and were more similar to each other than plaque stored in liquid dental transport medium. Saliva samples stored in OMNIgene recovered similar communities for at least a week following storage at room temperature. However, the microbial communities recovered from plaque and saliva stored in OMNIgene were significantly different in composition from their counterparts stored in liquid dental transport medium. Dental plaque communities collected from the same tooth type over four successive visits from the same adult did not significantly differ in structure or composition. Large-scale epidemiologic studies require collection over time and space, often with multiple teams collecting, storing, and processing data. Therefore, it is essential to understand how sensitive study results are to modest changes in collection and storage protocols that may occur with variation in personnel, resources available at a study site, and shipping requirements. The research presented in this paper measures the effects of multiple storage parameters and collection methodologies on the measured ecology of the oral microbiome from healthy adults and children. These results will potentially enable investigators to conduct oral microbiome studies at maximal efficiency by guiding informed administrative decisions pertaining to the necessary field or clinical work. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Luo, Ting; Srinivasan, Usha; Ramadugu, Kirtana; Shedden, Kerby A.; Neiswanger, Katherine; Trumble, Erika; Li, Jiean J.; McNeil, Daniel W.; Crout, Richard J.; Weyant, Robert J.; Marazita, Mary L.
2016-01-01
ABSTRACT Community profiling of the oral microbiome requires the recovery of quality sequences in order to accurately describe microbial community structure and composition. Our objective was to assess the effects of specimen collection method, storage medium, and storage conditions on the relative abundance of taxa in saliva and plaque identified using 16S rRNA genes. We also assessed short-term changes in taxon composition and relative abundance and compared the salivary and dental plaque communities in children and adults. Over a 2-week period, four successive saliva and dental plaque specimens were collected from four adults with no dental decay (108 samples), and two successive specimens were collected from six children with four or more erupted teeth (48 samples). There were minimal differences in community composition at the phylum and operational taxonomic unit levels between dental plaque collection using a scaler and collection using a CytoSoft brush. Plaque samples stored in OMNIgene medium showed higher within-sample Shannon diversity, were compositionally different, and were more similar to each other than plaque stored in liquid dental transport medium. Saliva samples stored in OMNIgene recovered similar communities for at least a week following storage at room temperature. However, the microbial communities recovered from plaque and saliva stored in OMNIgene were significantly different in composition from their counterparts stored in liquid dental transport medium. Dental plaque communities collected from the same tooth type over four successive visits from the same adult did not significantly differ in structure or composition. IMPORTANCE Large-scale epidemiologic studies require collection over time and space, often with multiple teams collecting, storing, and processing data. Therefore, it is essential to understand how sensitive study results are to modest changes in collection and storage protocols that may occur with variation in personnel, resources available at a study site, and shipping requirements. The research presented in this paper measures the effects of multiple storage parameters and collection methodologies on the measured ecology of the oral microbiome from healthy adults and children. These results will potentially enable investigators to conduct oral microbiome studies at maximal efficiency by guiding informed administrative decisions pertaining to the necessary field or clinical work. PMID:27371581
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michael Keane; Xiao-Chun Shi; Tong-man Ong
The project staff partnered with Costas Sioutas from the University of Southern California to apply the VACES (Versatile Aerosol Concentration Enhancement System) to a diesel engine test facility at West Virginia University Department of Mechanical Engineering and later the NIOSH Lake Lynn Mine facility. The VACES system was able to allow diesel exhaust particulate matter (DPM) to grow to sufficient particle size to be efficiently collected with the SKC Biosampler impinger device, directly into a suspension of simulated pulmonary surfactant. At the WVU-MAE facility, the concentration of the aerosol was too high to allow efficient use of the VACES concentrationmore » enhancement, although aerosol collection was successful. Collection at the LLL was excellent with the diluted exhaust stream. In excess of 50 samples were collected at the LLL facility, along with matching filter samples, at multiple engine speed and load conditions. Replicate samples were combined and concentration increased using a centrifugal concentrator. Bioassays were negative for all tested samples, but this is believed to be due to insufficient concentration in the final assay suspensions.« less
Characterizing lentic freshwater fish assemblages using multiple sampling methods
Fischer, Jesse R.; Quist, Michael C.
2014-01-01
Characterizing fish assemblages in lentic ecosystems is difficult, and multiple sampling methods are almost always necessary to gain reliable estimates of indices such as species richness. However, most research focused on lentic fish sampling methodology has targeted recreationally important species, and little to no information is available regarding the influence of multiple methods and timing (i.e., temporal variation) on characterizing entire fish assemblages. Therefore, six lakes and impoundments (48–1,557 ha surface area) were sampled seasonally with seven gear types to evaluate the combined influence of sampling methods and timing on the number of species and individuals sampled. Probabilities of detection for species indicated strong selectivities and seasonal trends that provide guidance on optimal seasons to use gears when targeting multiple species. The evaluation of species richness and number of individuals sampled using multiple gear combinations demonstrated that appreciable benefits over relatively few gears (e.g., to four) used in optimal seasons were not present. Specifically, over 90 % of the species encountered with all gear types and season combinations (N = 19) from six lakes and reservoirs were sampled with nighttime boat electrofishing in the fall and benthic trawling, modified-fyke, and mini-fyke netting during the summer. Our results indicated that the characterization of lentic fish assemblages was highly influenced by the selection of sampling gears and seasons, but did not appear to be influenced by waterbody type (i.e., natural lake, impoundment). The standardization of data collected with multiple methods and seasons to account for bias is imperative to monitoring of lentic ecosystems and will provide researchers with increased reliability in their interpretations and decisions made using information on lentic fish assemblages.
Multiport well design for sampling of ground water at closely spaced vertical intervals
Delin, G.N.; Landon, M.K.
1996-01-01
Detailed vertical sampling is useful in aquifers where vertical mixing is limited and steep vertical gradients in chemical concentrations are expected. Samples can be collected at closely spaced vertical intervals from nested wells with short screened intervals. However, this approach may not be appropriate in all situations. An easy-to-construct and easy-to-install multiport sampling well to collect ground-water samples from closely spaced vertical intervals was developed and tested. The multiport sampling well was designed to sample ground water from surficial sand-and-gravel aquifers. The device consists of multiple stainless-steel tubes within a polyvinyl chloride (PVC) protective casing. The tubes protrude through the wall of the PVC casing at the desired sampling depths. A peristaltic pump is used to collect ground-water samples from the sampling ports. The difference in hydraulic head between any two sampling ports can be measured with a vacuum pump and a modified manometer. The usefulness and versatility of this multiport well design was demonstrated at an agricultural research site near Princeton, Minnesota where sampling ports were installed to a maximum depth of about 12 m below land surface. Tracer experiments were conducted using potassium bromide to document the degree to which short-circuiting occurred between sampling ports. Samples were successfully collected for analysis of major cations and anions, nutrients, selected herbicides, isotopes, dissolved gases, and chlorofluorcarbon concentrations.
Oltmann, R.N.; Guay, J.R.; Shay, J.M.
1987-01-01
Data were collected as part of the National Urban Runoff Program to characterize urban runoff in Fresno, California. Rainfall-runoff quantity and quality data are included along with atmospheric dry-deposition and street-surface particulate quality data. The data are presented in figures and tables that reflect four land uses: industrial, single-dwelling residential, multiple-dwelling residential, and commercial. A total of 255 storms were monitored for rainfall and runoff quantity. Runoff samples from 112 of these storms were analyzed for physical, organic, inorganic, and biological constituents. The majority of the remaining storms have pH and specific conductance data only. Ninety-two composite rain samples were collected. Of these, 63 were analyzed for physical, inorganic, and (or) organic constituents. The remaining rainfall samples have pH and specific conductance data only. Nineteen atmospheric deposition and 21 street-particulate samples were collected and analyzed for inorganic and organic constituents. The report also details equipment utilization and operation, and discusses data collection methods. (USGS)
Ramey, Andy M.; Schmutz, Joel A.; Fleskes, Joseph P.; Yabsley, Michael J.
2013-01-01
Information on the molecular detection of hematozoa from different tissue types and multiple years would be useful to inform sample collection efforts and interpret results of meta-analyses or investigations spanning multiple seasons. In this study, we tested blood and muscle tissue collected from northern pintails (Anas acuta) during autumn and winter of different years to evaluate prevalence and genetic diversity ofLeucocytozoon, Haemoproteus, and Plasmodium infections in this abundant waterfowl species of the Central Valley of California. We first compared results for paired blood and wing muscle samples to assess the utility of different tissue types for molecular investigations of haemosporidian parasites. Second, we explored inter-annual variability of hematozoa infection in Central Valley northern pintails and investigated possible effects of age, sex, and sub-region of sample collection on estimated parasite detection probability and prevalence. We found limited evidence for differences between tissue types in detection probability and prevalence ofLeucocytozoon, Haemoproteus, and Plasmodium parasites, which supports the utility of both sample types for obtaining information on hematozoan infections. However, we detected 11 haemosporidian mtDNA cyt bhaplotypes in blood samples vs. six in wing muscle tissue collected during the same sample year suggesting an advantage to using blood samples for investigations of genetic diversity. Estimated prevalence ofLeucocytozoon parasites was greater during 2006–2007 as compared to 2011–2012 and four unique haemosporidian mtDNA cyt b haplotypes were detected in the former sample year but not in the latter. Seven of 15 mtDNA cyt b haplotypes detected in northern pintails had 100% identity with previously reported hematozoa lineages detected in waterfowl (Haemoproteus and Leucocytozoon) or other avian taxa (Plasmodium) providing support for lack of host specificity for some parasite lineages.
Aramli, M S; Kalbassi, M R; Gharibi, M R
2015-02-01
In this study, we investigated the effects of multiple collections of sperm on the endangered Persian sturgeon, Acipenser persicus, in terms of a number of sperm functional parameters (percentage of motile spermatozoa, total time period of motility and sperm concentration) as well as on the ionic composition, protein concentration and osmolality of seminal plasma. Semen samples were collected from 12 induced male fish in three experimental groups that had been injected intramuscularly with LHRH-A2, at dosages of 5 μg/kg body weight, at a number of time regimes: at 12 h, 17 h and 24 h after spawning induction (1); at 24, 29 and 34 h after spawning induction (2); and at 36, 41 and 46 h after spawning induction (3). The percentage of motile spermatozoa and the period of sperm motility decreased significantly (p < 0.05) after the second and third collections. The concentration of spermatozoa decreased after the third collection, but this decline was not significant. No significant effect of multiple collections on protein concentration and ionic content (with exception of the Cl(-) ion) of seminal plasma was observed. In all experimental groups, a moderate impact of sequential collection on the osmolality (p < 0.05) of seminal plasma was observed. This study provides new data on the effects of multiple collections on spermatological characteristics in the Persian sturgeon. Our results confirm that sequential stripping after the third collections has a negative effect on a number of functional parameters associated with sperm. Journal of Animal Physiology and Animal Nutrition © 2014 Blackwell Verlag GmbH.
Priest, Jeffrey W.; Jenks, M. Harley; Moss, Delynn M.; Mao, Bunsoth; Buth, Sokhal; Wannemuehler, Kathleen; Soeung, Sann Chan; Lucchi, Naomi W.; Udhayakumar, Venkatachalam; Gregory, Christopher J.; Huy, Rekol; Muth, Sinuon; Lammie, Patrick J.
2016-01-01
Collection of surveillance data is essential for monitoring and evaluation of public health programs. Integrated collection of household-based health data, now routinely carried out in many countries through demographic health surveys and multiple indicator surveys, provides critical measures of progress in health delivery. In contrast, biomarker surveys typically focus on single or related measures of malaria infection, HIV status, vaccination coverage, or immunity status for vaccine-preventable diseases (VPD). Here we describe an integrated biomarker survey based on use of a multiplex bead assay (MBA) to simultaneously measure antibody responses to multiple parasitic diseases of public health importance as part of a VPD serological survey in Cambodia. A nationally-representative cluster-based survey was used to collect serum samples from women of child-bearing age. Samples were tested by MBA for immunoglobulin G antibodies recognizing recombinant antigens from Plasmodium falciparum and P. vivax, Wuchereria bancrofti, Toxoplasma gondii, Taenia solium, and Strongyloides stercoralis. Serologic IgG antibody results were useful both for generating national prevalence estimates for the parasitic diseases of interest and for confirming the highly focal distributions of some of these infections. Integrated surveys offer an opportunity to systematically assess the status of multiple public health programs and measure progress toward Millennium Development Goals. PMID:27136913
Mackeh, Rafah; Boughorbel, Sabri; Chaussabel, Damien; Kino, Tomoshige
2017-01-01
The collection of large-scale datasets available in public repositories is rapidly growing and providing opportunities to identify and fill gaps in different fields of biomedical research. However, users of these datasets should be able to selectively browse datasets related to their field of interest. Here we made available a collection of transcriptome datasets related to human follicular cells from normal individuals or patients with polycystic ovary syndrome, in the process of their development, during in vitro fertilization. After RNA-seq dataset exclusion and careful selection based on study description and sample information, 12 datasets, encompassing a total of 85 unique transcriptome profiles, were identified in NCBI Gene Expression Omnibus and uploaded to the Gene Expression Browser (GXB), a web application specifically designed for interactive query and visualization of integrated large-scale data. Once annotated in GXB, multiple sample grouping has been made in order to create rank lists to allow easy data interpretation and comparison. The GXB tool also allows the users to browse a single gene across multiple projects to evaluate its expression profiles in multiple biological systems/conditions in a web-based customized graphical views. The curated dataset is accessible at the following link: http://ivf.gxbsidra.org/dm3/landing.gsp.
Mackeh, Rafah; Boughorbel, Sabri; Chaussabel, Damien; Kino, Tomoshige
2017-01-01
The collection of large-scale datasets available in public repositories is rapidly growing and providing opportunities to identify and fill gaps in different fields of biomedical research. However, users of these datasets should be able to selectively browse datasets related to their field of interest. Here we made available a collection of transcriptome datasets related to human follicular cells from normal individuals or patients with polycystic ovary syndrome, in the process of their development, during in vitro fertilization. After RNA-seq dataset exclusion and careful selection based on study description and sample information, 12 datasets, encompassing a total of 85 unique transcriptome profiles, were identified in NCBI Gene Expression Omnibus and uploaded to the Gene Expression Browser (GXB), a web application specifically designed for interactive query and visualization of integrated large-scale data. Once annotated in GXB, multiple sample grouping has been made in order to create rank lists to allow easy data interpretation and comparison. The GXB tool also allows the users to browse a single gene across multiple projects to evaluate its expression profiles in multiple biological systems/conditions in a web-based customized graphical views. The curated dataset is accessible at the following link: http://ivf.gxbsidra.org/dm3/landing.gsp. PMID:28413616
Use of Internet panels to conduct surveys.
Hays, Ron D; Liu, Honghu; Kapteyn, Arie
2015-09-01
The use of Internet panels to collect survey data is increasing because it is cost-effective, enables access to large and diverse samples quickly, takes less time than traditional methods to obtain data for analysis, and the standardization of the data collection process makes studies easy to replicate. A variety of probability-based panels have been created, including Telepanel/CentERpanel, Knowledge Networks (now GFK KnowledgePanel), the American Life Panel, the Longitudinal Internet Studies for the Social Sciences panel, and the Understanding America Study panel. Despite the advantage of having a known denominator (sampling frame), the probability-based Internet panels often have low recruitment participation rates, and some have argued that there is little practical difference between opting out of a probability sample and opting into a nonprobability (convenience) Internet panel. This article provides an overview of both probability-based and convenience panels, discussing potential benefits and cautions for each method, and summarizing the approaches used to weight panel respondents in order to better represent the underlying population. Challenges of using Internet panel data are discussed, including false answers, careless responses, giving the same answer repeatedly, getting multiple surveys from the same respondent, and panelists being members of multiple panels. More is to be learned about Internet panels generally and about Web-based data collection, as well as how to evaluate data collected using mobile devices and social-media platforms.
Application of Handheld Laser-Induced Breakdown Spectroscopy (LIBS) to Geochemical Analysis.
Connors, Brendan; Somers, Andrew; Day, David
2016-05-01
While laser-induced breakdown spectroscopy (LIBS) has been in use for decades, only within the last two years has technology progressed to the point of enabling true handheld, self-contained instruments. Several instruments are now commercially available with a range of capabilities and features. In this paper, the SciAps Z-500 handheld LIBS instrument functionality and sub-systems are reviewed. Several assayed geochemical sample sets, including igneous rocks and soils, are investigated. Calibration data are presented for multiple elements of interest along with examples of elemental mapping in heterogeneous samples. Sample preparation and the data collection method from multiple locations and data analysis are discussed. © The Author(s) 2016.
Evaluating Multiple Imputation Models for the Southern Annual Forest Inventory
Gregory A. Reams; Joseph M. McCollum
1999-01-01
The USDA Forest Service's Southern Research Station is implementing an annualized forest survey in thirteen states. The sample design is a systematic sample of five interpenetrating grids (panels), where each panel is measured sequentially. For example, panel one information is collected in year one, and panel five in year five. The area representative and time...
Implementation of Comprehensive School Reform and Its Impact on Increases in Student Achievement
ERIC Educational Resources Information Center
Zhang, Yu; Fashola, Olatokunbo; Shkolnik, Jamie; Boyle, Andrea
2006-01-01
This study examined the relationship between the implementation of comprehensive school reform (CSR) and changes in reading and math achievement from 1999 until 2003. Survey data about CSR implementation and school-level achievement data were collected for multiple years from a sample of CSR schools and compared with a sample of matched comparison…
Avelar, Daniel M; Linardi, Pedro M
2010-09-15
The recently developed Multiple Displacement Amplification technique (MDA) allows for the production of a large quantity of high quality genomic DNA from low amounts of the original DNA. The goal of this study was to evaluate the performance of the MDA technique to amplify genomic DNA of siphonapterids that have been stored for long periods in 70% ethanol at room temperature. We subjected each DNA sample to two different methodologies: (1) amplification of mitochondrial 16S sequences without MDA; (2) amplification of 16S after MDA. All the samples obtained from these procedures were then sequenced. Only 4 samples (15.4%) subjected to method 1 showed amplification. In contrast, the application of MDA (method 2) improved the performance substantially, with 24 samples (92.3%) showing amplification, with significant difference. Interestingly, one of the samples successfully amplified with this method was originally collected in 1909. All of the sequenced samples displayed satisfactory results in quality evaluations (Phred ≥ 20) and good similarities, as identified with the BLASTn tool. Our results demonstrate that the use of MDA may be an effective tool in molecular studies involving specimens of fleas that have traditionally been considered inadequately preserved for such purposes.
2010-01-01
The recently developed Multiple Displacement Amplification technique (MDA) allows for the production of a large quantity of high quality genomic DNA from low amounts of the original DNA. The goal of this study was to evaluate the performance of the MDA technique to amplify genomic DNA of siphonapterids that have been stored for long periods in 70% ethanol at room temperature. We subjected each DNA sample to two different methodologies: (1) amplification of mitochondrial 16S sequences without MDA; (2) amplification of 16S after MDA. All the samples obtained from these procedures were then sequenced. Only 4 samples (15.4%) subjected to method 1 showed amplification. In contrast, the application of MDA (method 2) improved the performance substantially, with 24 samples (92.3%) showing amplification, with significant difference. Interestingly, one of the samples successfully amplified with this method was originally collected in 1909. All of the sequenced samples displayed satisfactory results in quality evaluations (Phred ≥ 20) and good similarities, as identified with the BLASTn tool. Our results demonstrate that the use of MDA may be an effective tool in molecular studies involving specimens of fleas that have traditionally been considered inadequately preserved for such purposes. PMID:20840790
Robin M. Reich; Hans T. Schreuder
2006-01-01
The sampling strategy involving both statistical and in-place inventory information is presented for the natural resources project of the Green Belt area (Centuron Verde) in the Mexican state of Jalisco. The sampling designs used were a grid based ground sample of a 90x90 m plot and a two-stage stratified sample of 30 x 30 m plots. The data collected were used to...
Huang, Yunda; Huang, Ying; Moodie, Zoe; Li, Sue; Self, Steve
2014-01-01
Summary In biomedical research such as the development of vaccines for infectious diseases or cancer, measures from the same assay are often collected from multiple sources or laboratories. Measurement error that may vary between laboratories needs to be adjusted for when combining samples across laboratories. We incorporate such adjustment in comparing and combining independent samples from different labs via integration of external data, collected on paired samples from the same two laboratories. We propose: 1) normalization of individual level data from two laboratories to the same scale via the expectation of true measurements conditioning on the observed; 2) comparison of mean assay values between two independent samples in the Main study accounting for inter-source measurement error; and 3) sample size calculations of the paired-sample study so that hypothesis testing error rates are appropriately controlled in the Main study comparison. Because the goal is not to estimate the true underlying measurements but to combine data on the same scale, our proposed methods do not require that the true values for the errorprone measurements are known in the external data. Simulation results under a variety of scenarios demonstrate satisfactory finite sample performance of our proposed methods when measurement errors vary. We illustrate our methods using real ELISpot assay data generated by two HIV vaccine laboratories. PMID:22764070
Methods for collecting algal samples as part of the National Water-Quality Assessment Program
Porter, Stephen D.; Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.
1993-01-01
Benthic algae (periphyton) and phytoplankton communities are characterized in the U.S. Geological Survey's National Water-Quality Assessment Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. This multidisciplinary approach provides multiple lines of evidence for evaluating water-quality status and trends, and for refining an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. Water quality can be characterized by evaluating the results of qualitative and quantitative measurements of the algal community. Qualitative periphyton samples are collected to develop of list of taxa present in the sampling reach. Quantitative periphyton samples are collected to measure algal community structure within selected habitats. These samples of benthic algal communities are collected from natural substrates, using the sampling methods that are most appropriate for the habitat conditions. Phytoplankton samples may be collected in large nonwadeable streams and rivers to meet specific program objectives. Estimates of algal biomass (chlorophyll content and ash-free dry mass) also are optional measures that may be useful for interpreting water-quality conditions. A nationally consistent approach provides guidance on site, reach, and habitat selection, as well as information on methods and equipment for qualitative and quantitative sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data locally, regionally, and nationally.
ERIC Educational Resources Information Center
Kitchin, R. M.; Jacobson, R. D.
1997-01-01
Assesses techniques used by researchers to collect and analyze data on how people with visual impairments or blindness learn, understand, and think about geographic space. Recommendations are made for increasing the validity of studies, including the use of multiple, mutually supportive tests; larger samples; and real-world environments.…
Sampling for mercury at subnanogram per litre concentrations for load estimation in rivers
Colman, J.A.; Breault, R.F.
2000-01-01
Estimation of constituent loads in streams requires collection of stream samples that are representative of constituent concentrations, that is, composites of isokinetic multiple verticals collected along a stream transect. An all-Teflon isokinetic sampler (DH-81) cleaned in 75??C, 4 N HCl was tested using blank, split, and replicate samples to assess systematic and random sample contamination by mercury species. Mean mercury concentrations in field-equipment blanks were low: 0.135 ng??L-1 for total mercury (??Hg) and 0.0086 ng??L-1 for monomethyl mercury (MeHg). Mean square errors (MSE) for ??Hg and MeHg duplicate samples collected at eight sampling stations were not statistically different from MSE of samples split in the laboratory, which represent the analytical and splitting error. Low fieldblank concentrations and statistically equal duplicate- and split-sample MSE values indicate that no measurable contamination was occurring during sampling. Standard deviations associated with example mercury load estimations were four to five times larger, on a relative basis, than standard deviations calculated from duplicate samples, indicating that error of the load determination was primarily a function of the loading model used, not of sampling or analytical methods.
Human breath metabolomics using an optimized noninvasive exhaled breath condensate sampler
Zamuruyev, Konstantin O.; Aksenov, Alexander A.; Pasamontes, Alberto; Brown, Joshua F.; Pettit, Dayna R.; Foutouhi, Soraya; Weimer, Bart C.; Schivo, Michael; Kenyon, Nicholas J.; Delplanque, Jean-Pierre; Davis, Cristina E.
2017-01-01
Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of saliva droplets from the breath flow. Engineering an inexpensive device that allows efficient collection of metalomic-rich breath samples is intended to aid further advancement in the field of breath analysis for non-invasive health diagnostic. EBC sampling from human volunteers was performed under UC Davis IRB protocol 63701-3 (09/30/2014-07/07/2017). PMID:28004639
Human breath metabolomics using an optimized non-invasive exhaled breath condensate sampler.
Zamuruyev, Konstantin O; Aksenov, Alexander A; Pasamontes, Alberto; Brown, Joshua F; Pettit, Dayna R; Foutouhi, Soraya; Weimer, Bart C; Schivo, Michael; Kenyon, Nicholas J; Delplanque, Jean-Pierre; Davis, Cristina E
2016-12-22
Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube ™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of saliva droplets from the breath flow. Engineering an inexpensive device that allows efficient collection of metalomic-rich breath samples is intended to aid further advancement in the field of breath analysis for non-invasive health diagnostic. EBC sampling from human volunteers was performed under UC Davis IRB protocol 63701-3 (09/30/2014-07/07/2017).
Barros, Anthony; Ly, Van T; Chando, Theodore J; Ruan, Qian; Donenfeld, Scott L; Holub, David P; Christopher, Lisa J
2011-04-05
Microplate scintillation counters are utilized routinely in drug metabolism laboratories for the off-line radioanalysis of fractions collected during HPLC radioprofiling. In this process, the current fraction collection technology is limited by the number of plates that can be used per injection as well as the potential for sample loss due to dripping or spraying as the fraction collector head moves from well to well or between plates. More importantly, sample throughput is limited in the conventional process, since the collection plates must be manually exchanged after each injection. The Collect PAL, an innovative multiple-plate fraction collector, was developed to address these deficiencies and improve overall sample throughput. It employs a zero-loss design and has sub-ambient temperature control. Operation of the system is completely controlled with software and up to 24 (96- or 384-well) fraction collection plates can be loaded in a completely automated run. The system may also be configured for collection into various-sized tubes or vials. At flow rates of 0.5 or 1.0 mL/min and at collection times of 10 or 15s, the system precisely delivered 83-μL fractions (within 4.1% CV) and 250-μL fractions (within 1.4% CV), respectively, of three different mobile phases into 12 mm × 32 mm vials. Similarly, at a flow rate of 1 mL/min and 10s collection times, the system precisely dispensed mobile phase containing a [(14)C]-radiolabeled compound across an entire 96-well plate (% CV was within 5.3%). Triplicate analyses of metabolism test samples containing [(14)C]buspirone and its metabolites, derived from three different matrices (plasma, urine and bile), indicated that the Collect PAL produced radioprofiles that were reproducible and comparable to the current technology; the % CV for 9 selected peaks in the radioprofiles generated with the Collect PAL were within 9.3%. Radioprofiles generated by collecting into 96- and 384-well plates were qualitatively comparable; however, the peak resolution was greater in the profiles that were collected in 384-well plates due to the collection of a larger number of fractions per minute. In conclusion, this new and innovative fraction collector generated radioprofile results that were comparable to current technology and should provide a major improvement in capacity and throughput for radioprofiling studies. Copyright © 2010 Elsevier B.V. All rights reserved.
Bowler, Michael G; Bowler, Matthew W
2014-01-01
The advent of micro-focused X-ray beams has led to the development of a number of advanced methods of sample evaluation and data collection. In particular, multiple-position data-collection and helical oscillation strategies are now becoming commonplace in order to alleviate the problems associated with radiation damage. However, intra-crystal and inter-crystal variation means that it is not always obvious on which crystals or on which region or regions of a crystal these protocols should be performed. For the automation of this process for large-scale screening, and to provide an indication of the best strategy for data collection, a metric of crystal variability could be useful. Here, measures of the intrinsic variability within protein crystals are presented and their implications for optimal data-collection strategies are discussed.
Hyperspectral stimulated emission depletion microscopy and methods of use thereof
Timlin, Jerilyn A; Aaron, Jesse S
2014-04-01
A hyperspectral stimulated emission depletion ("STED") microscope system for high-resolution imaging of samples labeled with multiple fluorophores (e.g., two to ten fluorophores). The hyperspectral STED microscope includes a light source, optical systems configured for generating an excitation light beam and a depletion light beam, optical systems configured for focusing the excitation and depletion light beams on a sample, and systems for collecting and processing data generated by interaction of the excitation and depletion light beams with the sample. Hyperspectral STED data may be analyzed using multivariate curve resolution analysis techniques to deconvolute emission from the multiple fluorophores. The hyperspectral STED microscope described herein can be used for multi-color, subdiffraction imaging of samples (e.g., materials and biological materials) and for analyzing a tissue by Forster Resonance Energy Transfer ("FRET").
Valentino, Kristin; De Alba, Ashley; Hibel, Leah C; Fondren, Kaitlin; McDonnell, Christina G
2017-11-01
There has been increasing interest in evaluating whether interventions for child maltreatment can improve and/or prevent child physiological dysregulation via measurement of diurnal cortisol. The assessment of diurnal cortisol typically involves the home-based collection of saliva multiple times per day, bringing forth important methodological considerations regarding adherence to collection instructions. To date, there has been no data regarding adherence to home collection of diurnal cortisol among maltreating families. The current study provides data on adherence to in-home sampling of salivary cortisol among 166 maltreating and demographically similar nonmaltreating mother-child dyads using electronic monitoring devices (Medication Event Monitoring System caps). Mothers collected saliva samples on themselves and their children 3 times per day (waking, midday, and evening) for 2 consecutive days. Analyses reveal that although maltreating families were more likely to be nonadherent to the collection protocol on their initial attempt, with additional support and resampling, maltreating and nonmaltreating families were comparable on most measures of adherence. Suggestions for best practices, including the use of electronic monitoring devices, for diurnal cortisol collection with maltreating families are provided.
Hladik, Michelle; Orlando, James L.; Kuivila, Kathryn
2009-01-01
Loss of pyrethroid insecticides onto surfaces during sample collection can confound the interpretation of analytical and toxicity test results. Sample collection devices, container materials, and water matrix composition have a significant influence on the association of pyrethroids to container walls, which can be as high as 50 percent. Any sample collection method involving transfer through multiple containers or pieces of equipment increases the potential for pyrethroid loss. This loose 'surface-association' with container walls can be reversed through agitation. When sampling water matrices with pumps or autosamplers, no pyrethroids were lost as long as the water was moving continuously through the system. When collecting water matrices in containers, the material with the least amount of pyrethroid sorption is as follows: glass less than (<) plastic less than (<) Teflon. Additionally, pyrethroids were easier to re-suspend from the glass container walls. Since the amount of surface-association is proportional to the ratio of volume-to-contact-area of the sample, taking larger-volume field samples (greater than 3 liters) reduced pyrethroid losses to less than 10 percent. The amount of surface-association cannot be predicted easily because of the dependence on water matrix composition; samples with higher dissolved organic carbon or suspended-sediment concentrations were observed to have lower percent loss. Sediment samples were not affected by glass-container sorption (the only containers tested). Standardized sample-collection protocols are critical to yield accurate pyrethroid concentrations for assessment of potential effects, and have been summarized in an accompanying standard operating procedure.
Zhong, Daibin; Lo, Eugenia; Wang, Xiaoming; Yewhalaw, Delenasaw; Zhou, Guofa; Atieli, Harrysone E; Githeko, Andrew; Hemming-Schroeder, Elizabeth; Lee, Ming-Chieh; Afrane, Yaw; Yan, Guiyun
2018-05-02
Parasite genetic diversity and multiplicity of infection (MOI) affect clinical outcomes, response to drug treatment and naturally-acquired or vaccine-induced immunity. Traditional methods often underestimate the frequency and diversity of multiclonal infections due to technical sensitivity and specificity. Next-generation sequencing techniques provide a novel opportunity to study complexity of parasite populations and molecular epidemiology. Symptomatic and asymptomatic Plasmodium vivax samples were collected from health centres/hospitals and schools, respectively, from 2011 to 2015 in Ethiopia. Similarly, both symptomatic and asymptomatic Plasmodium falciparum samples were collected, respectively, from hospitals and schools in 2005 and 2015 in Kenya. Finger-pricked blood samples were collected and dried on filter paper. Long amplicon (> 400 bp) deep sequencing of merozoite surface protein 1 (msp1) gene was conducted to determine multiplicity and molecular epidemiology of P. vivax and P. falciparum infections. The results were compared with those based on short amplicon (117 bp) deep sequencing. A total of 139 P. vivax and 222 P. falciparum samples were pyro-sequenced for pvmsp1 and pfmsp1, yielding a total of 21 P. vivax and 99 P. falciparum predominant haplotypes. The average MOI for P. vivax and P. falciparum were 2.16 and 2.68, respectively, which were significantly higher than that of microsatellite markers and short amplicon (117 bp) deep sequencing. Multiclonal infections were detected in 62.2% of the samples for P. vivax and 74.8% of the samples for P. falciparum. Four out of the five subjects with recurrent P. vivax malaria were found to be a relapse 44-65 days after clearance of parasites. No difference was observed in MOI among P. vivax patients of different symptoms, ages and genders. Similar patterns were also observed in P. falciparum except for one study site in Kenyan lowland areas with significantly higher MOI. The study used a novel method to evaluate Plasmodium MOI and molecular epidemiological patterns by long amplicon ultra-deep sequencing. The complexity of infections were similar among age groups, symptoms, genders, transmission settings (spatial heterogeneity), as well as over years (pre- vs. post-scale-up interventions). This study demonstrated that long amplicon deep sequencing is a useful tool to investigate multiplicity and molecular epidemiology of Plasmodium parasite infections.
Conducting On-orbit Gene Expression Analysis on ISS: WetLab-2
NASA Technical Reports Server (NTRS)
Parra, Macarena; Almeida, Eduardo; Boone, Travis; Jung, Jimmy; Lera, Matthew P.; Ricco, Antonio; Souza, Kenneth; Wu, Diana; Richey, C. Scott
2013-01-01
WetLab-2 will enable expanded genomic research on orbit by developing tools that support in situ sample collection, processing, and analysis on ISS. This capability will reduce the time-to-results for investigators and define new pathways for discovery on the ISS National Lab. The primary objective is to develop a research platform on ISS that will facilitate real-time quantitative gene expression analysis of biological samples collected on orbit. WetLab-2 will be capable of processing multiple sample types ranging from microbial cultures to animal tissues dissected on orbit. WetLab-2 will significantly expand the analytical capabilities onboard ISS and enhance science return from ISS.
Exposure assessment for endocrine disruptors: some considerations in the design of studies.
Rice, Carol; Birnbaum, Linda S; Cogliano, James; Mahaffey, Kathryn; Needham, Larry; Rogan, Walter J; vom Saal, Frederick S
2003-01-01
In studies designed to evaluate exposure-response relationships in children's development from conception through puberty, multiple factors that affect the generation of meaningful exposure metrics must be considered. These factors include multiple routes of exposure; the timing, frequency, and duration of exposure; need for qualitative and quantitative data; sample collection and storage protocols; and the selection and documentation of analytic methods. The methods for exposure data collection and analysis must be sufficiently robust to accommodate the a priori hypotheses to be tested, as well as hypotheses generated from the data. A number of issues that must be considered in study design are summarized here. PMID:14527851
ERIC Educational Resources Information Center
Qing, Siyu
2014-01-01
The National Science Foundation (NSF) Survey of Doctorate Recipients (SDR) collects information on a sample of individuals in the United States with PhD degrees. A significant portion of the sampled individuals appear in multiple survey years and can be linked across time. Survey weights in each year are created and adjusted for oversampling and…
de Castro, Francine Attié; Simões, Belinda Pinto; Coelho, Eduardo Barbosa; Lanchote, Vera Lucia
2017-06-01
The aim of this study was to evaluate the enantioselective pharmacokinetics of cyclophosphamide and its metabolites 4-hydroxycyclophosphamide and carboxyethylphosphoramide mustard in patients with systemic or multiple sclerosis. Patients with systemic sclerosis (n = 10) or multiple sclerosis (n = 10), genotyped for the allelic variants of CYP2C9*2 and CYP2C9*3 and of the CYP2B6 G516T polymorphism, were treated with 50 mg cyclophosphamide/kg daily for 4 days. Serial blood samples were collected up to 24 hours after administration of the last cyclophosphamide dose. Cyclophosphamide, 4-hydroxycyclophosphamide, and carboxyethylphosphoramide enantiomers were analyzed in plasma samples using liquid chromatography-tandem mass spectrometry coupled to chiral column Chiralcel OD-R or Chiralpak AD-RH. Cytokines IL-2, IL-4, IL-6, IL-8, IL-10, IL- 12p70, IL-17, TNF-α, and INT-δ in the plasma samples collected before cyclophosphamide infusion were analyzed by Milliplex MAP human cytokine/chemokine. Pharmacokinetic parameters showed higher plasma concentrations of (S)-(-)-cyclophosphamide (AUC 215.0 vs 186.2 μg·h/mL for multiple sclerosis patients and 219.1 vs 179.2 μg·h/mL for systemic sclerosis patients) and (R)-4-hydroxycyclophosphamide (AUC 5.6 vs 3.7 μg·h/mL for multiple sclerosis patients and 6.3 vs 5.6 μg·h/mL for systemic sclerosis patients) when compared to their enantiomers in both groups of patients, whereas the pharmacokinetics of the carboxyethylphosphoramide metabolite was not enantioselective. Cytokines' plasma concentrations were similar between multiple and systemic sclerosis groups. The pharmacokinetics of cyclophosphamide is enantioselective in patients with systemic sclerosis and multiple sclerosis, with higher plasma concentrations of the (S)-(-)-cyclophosphamide enantiomer due to the preferential formation of the (R)-4-hydroxycyclophosphamide metabolite. © 2017, The American College of Clinical Pharmacology.
Collecting and Storing Blood Samples From Patients With Cancer
2011-12-08
Brain and Central Nervous System Tumors; Chronic Myeloproliferative Disorders; Leukemia; Lymphoma; Lymphoproliferative Disorder; Multiple Myeloma and Plasma Cell Neoplasm; Myelodysplastic Syndromes; Myelodysplastic/Myeloproliferative Neoplasms; Nonmalignant Neoplasm; Unspecified Adult Solid Tumor, Protocol Specific; Unspecified Childhood Solid Tumor, Protocol Specific
Collecting and Storing Tissue and DNA Samples From Patients Undergoing a Donor Stem Cell Transplant
2012-11-04
Breast Cancer; Chronic Myeloproliferative Disorders; Gestational Trophoblastic Tumor; Graft Versus Host Disease; Leukemia; Lymphoma; Multiple Myeloma and Plasma Cell Neoplasm; Myelodysplastic Syndromes; Myelodysplastic/Myeloproliferative Neoplasms; Neuroblastoma; Ovarian Cancer; Testicular Germ Cell Tumor
NASA Astrophysics Data System (ADS)
Kim, Stephan D.; Luo, Jiajun; Buchholz, D. Bruce; Chang, R. P. H.; Grayson, M.
2016-09-01
A modular time division multiplexer (MTDM) device is introduced to enable parallel measurement of multiple samples with both fast and slow decay transients spanning from millisecond to month-long time scales. This is achieved by dedicating a single high-speed measurement instrument for rapid data collection at the start of a transient, and by multiplexing a second low-speed measurement instrument for slow data collection of several samples in parallel for the later transients. The MTDM is a high-level design concept that can in principle measure an arbitrary number of samples, and the low cost implementation here allows up to 16 samples to be measured in parallel over several months, reducing the total ensemble measurement duration and equipment usage by as much as an order of magnitude without sacrificing fidelity. The MTDM was successfully demonstrated by simultaneously measuring the photoconductivity of three amorphous indium-gallium-zinc-oxide thin films with 20 ms data resolution for fast transients and an uninterrupted parallel run time of over 20 days. The MTDM has potential applications in many areas of research that manifest response times spanning many orders of magnitude, such as photovoltaics, rechargeable batteries, amorphous semiconductors such as silicon and amorphous indium-gallium-zinc-oxide.
Kim, Stephan D; Luo, Jiajun; Buchholz, D Bruce; Chang, R P H; Grayson, M
2016-09-01
A modular time division multiplexer (MTDM) device is introduced to enable parallel measurement of multiple samples with both fast and slow decay transients spanning from millisecond to month-long time scales. This is achieved by dedicating a single high-speed measurement instrument for rapid data collection at the start of a transient, and by multiplexing a second low-speed measurement instrument for slow data collection of several samples in parallel for the later transients. The MTDM is a high-level design concept that can in principle measure an arbitrary number of samples, and the low cost implementation here allows up to 16 samples to be measured in parallel over several months, reducing the total ensemble measurement duration and equipment usage by as much as an order of magnitude without sacrificing fidelity. The MTDM was successfully demonstrated by simultaneously measuring the photoconductivity of three amorphous indium-gallium-zinc-oxide thin films with 20 ms data resolution for fast transients and an uninterrupted parallel run time of over 20 days. The MTDM has potential applications in many areas of research that manifest response times spanning many orders of magnitude, such as photovoltaics, rechargeable batteries, amorphous semiconductors such as silicon and amorphous indium-gallium-zinc-oxide.
Rosenberg, Matthew B; Dockery, Christopher R
2008-11-01
Laser-induced breakdown spectroscopy (LIBS) has been used to determine the period of time that a shooter will test positive for gunshot residue (GSR) after firing a revolver. Multiple rounds of primer were fired and samples collected at multiple hour intervals using an adhesive tape pressed against the skin. Samples were analyzed directly using a commercially available laser-induced breakdown spectrometer where barium emission (originating from barium nitrate in the primer) was observed. Population statistics were used to compare suspected GSR to a library of blank samples from which a threshold value was established. Statistically significant results, positive for GSR, are obtained 5.27 days after a firearm discharge using these techniques.
Unscaled Bayes factors for multiple hypothesis testing in microarray experiments.
Bertolino, Francesco; Cabras, Stefano; Castellanos, Maria Eugenia; Racugno, Walter
2015-12-01
Multiple hypothesis testing collects a series of techniques usually based on p-values as a summary of the available evidence from many statistical tests. In hypothesis testing, under a Bayesian perspective, the evidence for a specified hypothesis against an alternative, conditionally on data, is given by the Bayes factor. In this study, we approach multiple hypothesis testing based on both Bayes factors and p-values, regarding multiple hypothesis testing as a multiple model selection problem. To obtain the Bayes factors we assume default priors that are typically improper. In this case, the Bayes factor is usually undetermined due to the ratio of prior pseudo-constants. We show that ignoring prior pseudo-constants leads to unscaled Bayes factor which do not invalidate the inferential procedure in multiple hypothesis testing, because they are used within a comparative scheme. In fact, using partial information from the p-values, we are able to approximate the sampling null distribution of the unscaled Bayes factor and use it within Efron's multiple testing procedure. The simulation study suggests that under normal sampling model and even with small sample sizes, our approach provides false positive and false negative proportions that are less than other common multiple hypothesis testing approaches based only on p-values. The proposed procedure is illustrated in two simulation studies, and the advantages of its use are showed in the analysis of two microarray experiments. © The Author(s) 2011.
Lippmann, M.
1964-04-01
A cascade particle impactor capable of collecting particles and distributing them according to size is described. In addition the device is capable of collecting on a pair of slides a series of different samples so that less time is required for the changing of slides. Other features of the device are its compactness and its ruggedness making it useful under field conditions. Essentially the unit consists of a main body with a series of transverse jets discharging on a pair of parallel, spaced glass plates. The plates are capable of being moved incremental in steps to obtain the multiple samples. (AEC)
A new sampler for stratified lagoon chemical and microbiological assessments.
McLaughlin, M R; Brooks, J P; Adeli, A
2014-07-01
A sampler was needed for a spatial and temporal study of microbial and chemical stratification in a large swine manure lagoon that was known to contain zoonotic bacteria. Conventional samplers were limited to collections of surface water samples near the bank or required a manned boat. A new sampler was developed to allow simultaneous collection of multiple samples at different depths, up to 2.3 m, without a manned boat. The sampler was tethered for stability, used remote control (RC) for sample collection, and accommodated rapid replacement of sterile tubing modules and sample containers. The sampler comprised a PVC pontoon with acrylic deck and watertight enclosures, for a 12 VDC gearmotor, to operate the collection module, and vacuum system, to draw samples into reusable autoclavable tubing and 250-mL bottles. Although designed primarily for water samples, the sampler was easily modified to collect sludge. The sampler held a stable position during deployment, created minimal disturbance in the water column, and was readily cleaned and sanitized for transport. The sampler was field tested initially in a shallow fresh water lake and subsequently in a swine manure treatment lagoon. Analyses of water samples from the lagoon tests showed that chemical and bacterial levels, pH, and EC did not differ between 0.04, 0.47, and 1.0 m depths, but some chemical and bacterial levels differed between winter and spring collections. These results demonstrated the utility of the sampler and suggested that future manure lagoon studies employ fewer or different depths and more sampling dates.
Laboratory information management system: an example of international cooperation in Namibia.
Colangeli, Patrizia; Ferrilli, Monica; Quaranta, Fabrizio; Malizia, Elio; Mbulu, Rosa-Stella; Mukete, Esther; Iipumbu, Lukas; Kamhulu, Anna; Tjipura-Zaire, Georgina; Di Francesco, Cesare; Lelli, Rossella; Scacchia, Massimo
2012-01-01
The authors describe the project undertaken by the Istituto G. Caporale to provide a laboratory information management system (LIMS) to the Central Veterinary Laboratory (CVL) in Windhoek, Namibia. This robust laboratory management tool satisfies Namibia's information obligations under international quality standard ISO 17025:2005. The Laboratory Information Management System (LIMS) for Africa was designed to collect and manage all necessary information on samples, tests and test results. The system involves the entry of sample data on arrival, as required by Namibian sampling plans, the tracking of samples through the various sections of the CVL, the collection of test results, generation of test reports and monitoring of outbreaks through data interrogation functions, eliminating multiple registrations of the same data on paper records. It is a fundamental component of the Namibian veterinary information system.
Factors associated with number of duodenal samples obtained in suspected celiac disease.
Shamban, Leonid; Sorser, Serge; Naydin, Stan; Lebwohl, Benjamin; Shukr, Mousa; Wiemann, Charlotte; Yevsyukov, Daniel; Piper, Michael H; Warren, Bradley; Green, Peter H R
2017-12-01
Many people with celiac disease are undiagnosed and there is evidence that insufficient duodenal samples may contribute to underdiagnosis. The aims of this study were to investigate whether more samples leads to a greater likelihood of a diagnosis of celiac disease and to elucidate factors that influence the number of samples collected. We identified patients from two community hospitals who were undergoing duodenal biopsy for indications (as identified by International Classification of Diseases code) compatible with possible celiac disease. Three cohorts were evaluated: no celiac disease (NCD, normal villi), celiac disease (villous atrophy, Marsh score 3), and possible celiac disease (PCD, Marsh score < 3). Endoscopic features, indication, setting, trainee presence, and patient demographic details were evaluated for their role in sample collection. 5997 patients met the inclusion criteria. Patients with a final diagnosis of celiac disease had a median of 4 specimens collected. The percentage of patients diagnosed with celiac disease with one sample was 0.3 % compared with 12.8 % of those with six samples ( P = 0.001). Patient factors that positively correlated with the number of samples collected were endoscopic features, demographic details, and indication ( P = 0.001). Endoscopist factors that positively correlated with the number of samples collected were absence of a trainee, pediatric gastroenterologist, and outpatient setting ( P < 0.001). Histological diagnosis of celiac disease significantly increased with six samples. Multiple factors influenced whether adequate biopsies were taken. Adherence to guidelines may increase the diagnosis rate of celiac disease.
Multivariate analysis: greater insights into complex systems
USDA-ARS?s Scientific Manuscript database
Many agronomic researchers measure and collect multiple response variables in an effort to understand the more complex nature of the system being studied. Multivariate (MV) statistical methods encompass the simultaneous analysis of all random variables (RV) measured on each experimental or sampling ...
Evaluation of Bio-VOC Sampler for Analysis of Volatile Organic Compounds in Exhaled Breath
Kwak, Jae; Fan, Maomian; Harshman, Sean W.; Garrison, Catherine E.; Dershem, Victoria L.; Phillips, Jeffrey B.; Grigsby, Claude C.; Ott, Darrin K.
2014-01-01
Monitoring volatile organic compounds (VOCs) from exhaled breath has been used to determine exposures of humans to chemicals. Prior to analysis of VOCs, breath samples are often collected with canisters or bags and concentrated. The Bio-VOC breath sampler, a commercial sampling device, has been recently introduced to the market with growing use. The main advantage for this sampler is to collect the last portion of exhaled breath, which is more likely to represent the air deep in the lungs. However, information about the Bio-VOC sampler is somewhat limited. Therefore, we have thoroughly evaluated the sampler here. We determined the volume of the breath air collected in the sampler was approximately 88 mL. When sampling was repeated multiple times, with the succeeding exhalations applied to a single sorbent tube, we observed linear relationships between the normalized peak intensity and the number of repeated collections with the sampler in many of the breath VOCs detected. No moisture effect was observed on the Tenax sorbent tubes used. However, due to the limitation in the collection volume, the use of the Bio-VOC sampler is recommended only for detection of VOCs present at high concentrations unless repeated collections of breath samples on the sampler are conducted. PMID:25532709
Roth, A M; Rosenberger, J G; Reece, M; Van Der Pol, B
2013-04-01
Routine screening is a key component of sexually transmitted infection (STI) prevention and control; however, traditional programmes often fail to effectively reach men and women in hidden communities. To reduce prevalence, we must understand the programmatic features that would encourage utilization of services among asymptomatic individuals. Using incentivized snowball sampling, 44 women and men recently engaging in transactional sex were recruited (24 women, 20 men); median age 37 years. Respondents were offered the opportunity to collect genital, oropharyngeal and rectal samples for STI testing and completed a face-to-face interview about their experience with self-obtained sampling. Interviews were analysed using qualitative methods. Participants were unaware of potential risk for STI, but found self-sampling in non-clinical settings to be acceptable and preferable to clinic-based testing. All participants collected genital specimens; 96% and 4% collected oropharyngeal and rectal specimens, respectively. The burden of disease in this population was high: 38% tested positive for at least one STI. We detected multiple concomitant infections. Incorporating field collection of self-obtained samples into STI control programmes may increase utilization among high-risk populations unlikely to access clinic-based services. High infection rates indicate that individuals engaging in transactional sex would benefit from, and be responsive to, community-based self-sampling for STI screening.
Design tradeoffs for trend assessment in aquatic biological monitoring programs
Gurtz, Martin E.; Van Sickle, John; Carlisle, Daren M.; Paulsen, Steven G.
2013-01-01
Assessments of long-term (multiyear) temporal trends in biological monitoring programs are generally undertaken without an adequate understanding of the temporal variability of biological communities. When the sources and levels of variability are unknown, managers cannot make informed choices in sampling design to achieve monitoring goals in a cost-effective manner. We evaluated different trend sampling designs by estimating components of both short- and long-term variability in biological indicators of water quality in streams. Invertebrate samples were collected from 32 sites—9 urban, 6 agricultural, and 17 relatively undisturbed (reference) streams—distributed throughout the United States. Between 5 and 12 yearly samples were collected at each site during the period 1993–2008, plus 2 samples within a 10-week index period during either 2007 or 2008. These data allowed calculation of four sources of variance for invertebrate indicators: among sites, among years within sites, interaction among sites and years (site-specific annual variation), and among samples collected within an index period at a site (residual). When estimates of these variance components are known, changes to sampling design can be made to improve trend detection. Design modifications that result in the ability to detect the smallest trend with the fewest samples are, from most to least effective: (1) increasing the number of years in the sampling period (duration of the monitoring program), (2) decreasing the interval between samples, and (3) increasing the number of repeat-visit samples per year (within an index period). This order of improvement in trend detection, which achieves the greatest gain for the fewest samples, is the same whether trends are assessed at an individual site or an average trend of multiple sites. In multiple-site surveys, increasing the number of sites has an effect similar to that of decreasing the sampling interval; the benefit of adding sites is greater when a new set of different sites is selected for each sampling effort than when the same sites are sampled each time. Understanding variance components of the ecological attributes of interest can lead to more cost-effective monitoring designs to detect trends.
Selbig, William R.; ,; Roger T. Bannerman,
2011-01-01
A new depth-integrated sample arm (DISA) was developed to improve the representation of solids in stormwater, both organic and inorganic, by collecting a water quality sample from multiple points in the water column. Data from this study demonstrate the idea of vertical stratification of solids in storm sewer runoff. Concentrations of suspended sediment in runoff were statistically greater using a fixed rather than multipoint collection system. Median suspended sediment concentrations measured at the fixed location (near the pipe invert) were approximately double those collected using the DISA. In general, concentrations and size distributions of suspended sediment decreased with increasing vertical distance from the storm sewer invert. Coarser particles tended to dominate the distribution of solids near the storm sewer invert as discharge increased. In contrast to concentration and particle size, organic material, to some extent, was distributed homogenously throughout the water column, likely the result of its low specific density, which allows for thorough mixing in less turbulent water.
Selbig, William R; Bannerman, Roger T
2011-04-01
A new depth-integrated sample arm (DISA) was developed to improve the representation of solids in stormwater, both organic and inorganic, by collecting a water quality sample from multiple points in the water column. Data from this study demonstrate the idea of vertical stratification of solids in storm sewer runoff. Concentrations of suspended sediment in runoff were statistically greater using a fixed rather than multipoint collection system. Median suspended sediment concentrations measured at the fixed location (near the pipe invert) were approximately double those collected using the DISA. In general, concentrations and size distributions of suspended sediment decreased with increasing vertical distance from the storm sewer invert. Coarser particles tended to dominate the distribution of solids near the storm sewer invert as discharge increased. In contrast to concentration and particle size, organic material, to some extent, was distributed homogenously throughout the water column, likely the result of its low specific density, which allows for thorough mixing in less turbulent water.
Selbig, W.R.; Bannerman, R.T.
2011-01-01
A new depth-integrated sample arm (DISA) was developed to improve the representation of solids in stormwater, both organic and inorganic, by collecting a water quality sample from multiple points in the water column. Data from this study demonstrate the idea of vertical stratification of solids in storm sewer runoff. Concentrations of suspended sediment in runoff were statistically greater using a fixed rather than multipoint collection system. Median suspended sediment concentrations measured at the fixed location (near the pipe invert) were approximately double those collected using the DISA. In general, concentrations and size distributions of suspended sediment decreased with increasing vertical distance from the storm sewer invert. Coarser particles tended to dominate the distribution of solids near the storm sewer invert as discharge increased. In contrast to concentration and particle size, organic material, to some extent, was distributed homogenously throughout the water column, likely the result of its low specific density, which allows for thorough mixing in less turbulent water. ?? 2010 Publishing Technology.
Fogarty, Lisa R.; Duris, Joseph W.; Crowley, Suzanne L.; Hardigan, Nicole
2007-01-01
Water samples collected from 20 stream sites in Oakland and Macomb Counties, Mich., were analyzed to learn more about the occurrence of cephalosporin-resistant Escherichia coli (E. coli) and vancomycin-resistant enterococci (VRE) and the co-occurrence of antibiotics and mercury in area streams. Fecal indicator bacteria concentrations exceeded the Michigan recreational water-quality standard of 300 E. coli colony forming units (CFU) per 100 milliliters of water in 19 of 35 stream-water samples collected in Oakland County. A gene commonly associated with enterococci from humans was detected in samples from Paint Creek at Rochester and Evans Ditch at Southfield, indicating that human fecal waste is a possible source of fecal contamination at these sites. E. coli resistant to the cephalosporin antibiotics (cefoxitin and/ or ceftriaxone) were found at all sites on at least one occasion. The highest percentages of E. coli isolates resistant to cefoxitin and ceftriaxone were 71 percent (Clinton River at Auburn Hills) and 19 percent (Sashabaw Creek near Drayton Plains), respectively. Cephalosporin-resistant E. coli was detected more frequently in samples from intensively urbanized or industrialized areas than in samples from less urbanized areas. VRE were not detected in any sample collected in this study. Multiple antibiotics (azithromycin, erythromycin, ofloxacin, sulfamethoxazole, and trimethoprim) were detected in water samples from the Clinton River at Auburn Hills, and tylosin (an antibiotic used in veterinary medicine and livestock production that belongs to the macrolide group, along with erythromycin) was detected in one water sample from Paint Creek at Rochester. Concentrations of total mercury were as high as 19.8 nanograms per liter (Evans Ditch at Southfield). There was no relation among percentage of antibiotic-resistant bacteria and measured concentrations of antibiotics or mercury in the water. Genetic elements capable of exchanging multiple antibiotic-resistance genes (class I integrons) were detected in several samples, indicating that the resistance carried by these organisms may be transferable to other bacteria, including disease-causing bacteria.
Morrill, K M; Robertson, K E; Spring, M M; Robinson, A L; Tyler, H D
2015-01-01
The objectives of this study were to (1) validate a method using refractometry to rapidly and accurately determine immunoglobulin (IgG) concentration in Jersey colostrum, (2) determine whether there should be different refractive index (nD) and %Brix cut points for Jersey colostrum, and (3) evaluate the effect of multiple freeze-thaw (FT) cycles on radial immunodiffusion (RID) and a digital refractometer to determine IgG concentration in Jersey colostrum. Samples (n=58; 3L) of colostrum were collected from a dairy in northwestern Iowa. Samples were analyzed within 2h of collection for IgG concentration by RID, %Brix, and nD by refractometer and an estimate of IgG by colostrometer. Samples were frozen, placed on dry ice, and transported to the laboratory at Iowa State University (Ames). Samples arrived frozen and were placed in a -20°C manual-defrost freezer until further analysis. On d 7 (1FT), d 14 (2FT), and 1yr (3FT) all samples were thawed, analyzed for IgG by RID, %Brix, nD by refractometer, and IgG estimate by colostrometer, and frozen until reanalysis at the next time point. Fresh colostrum had a mean (±SD) IgG concentration of 72.91 (±33.53) mg/mL, 21.24% (±4.43) Brix, and nD 1.3669 (±0.0074). Multiple FT cycles did affect IgG as determined by RID and colostrometer reading. The IgG concentrations were greater in fresh and 1FT samples as compared with 2FT and 3FT samples (72.91, 75.38, 67.20, and 67.31mg of IgG/mL, respectively). The colostrometer reading was lower in 1FT samples compared with fresh and 2FT samples. Multiple FT cycles had no effect on nD or %Brix reading. In fresh samples, IgG concentration was moderately correlated with nD (r=0.79), %Brix (r=0.79), and colostrometer reading (r=0.79). Diagnostic test characteristics using the recommended cut point of 1.35966 nD resulted in similar sensitivities for 1FT and 2 FT samples (94.87 and 94.74%, respectively). Cut points of 18 and 19% Brix resulted in the greatest sensitivities (92.31 and 84.62%) and specificity (94.74 and 94.74%, respectively). The 18% Brix cut point resulted in 94.83% of the samples being correctly classified based on IgG concentration. These data support the use of digital refractometer to accurately and rapidly determine IgG concentration in fresh Jersey colostrum. Additionally, these data suggest that IgG concentration determined by RID is affected by multiple FT cycles, whereas estimates obtained by refractometer are not affected by multiple FT cycles. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Urban Air Toxics Monitoring Program, 1989
DOE Office of Scientific and Technical Information (OSTI.GOV)
McAllister, R.A.; Moore, W.H.; Rice, J.
1990-10-01
From January 1989 through January 1990 samples of ambient air were collected at 14 sites in the eastern part of the U.S. Every 12 days, air was integrated over 24-hour periods into passivated stainless steel canisters. Simultaneously, air was drawn through cartridges containing dinitrophenylhydrazine to collect carbonyl compounds. The samples were analyzed at a central laboratory for a total of 37 halogenated and aromatic hydrocarbons, formaldehyde, acetaldehyde, and other oxygenated species. The hydrocarbon species were analyzed by gas chromatography/multiple detectors and gas chromatography/mass spectrometry, while the carbonyl species were analyzed by liquid chromatography. An extensive quality assurance program was carriedmore » on to secure high quality data. Complete data for all the carbonyl samples are presented in the report.« less
Özkan Tuncay, Fatma; Mollaoğlu, Mukadder
2017-12-01
To determine the effects of cooling suit on fatigue and activities of daily living of individuals with multiple sclerosis. Fatigue is one of the most common symptoms in people with multiple sclerosis and adversely affects their activities of daily living. Studies evaluating fatigue associated with multiple sclerosis have reported that most of the fatigue cases are related to the increase in body temperature and that cooling therapy is effective in coping with fatigue. This study used a two sample, control group design. The study sample comprised 75 individuals who met the inclusion criteria. Data were collected with study forms. After the study data were collected, cooling suit treatment was administered to the experimental group. During home visits paid at the fourth and eighth weeks after the intervention, the aforementioned scales were re-administered to the participants in the experimental and control groups. The analyses performed demonstrated that the severity levels of fatigue experienced by the participants in the experimental group wearing cooling suit decreased. The experimental group also exhibited a significant improvement in the participants' levels of independence in activities of daily living. The cooling suit worn by individuals with multiple sclerosis was determined to significantly improve the participants' levels of fatigue and independence in activities of daily living. The cooling suit therapy was found to be an effective intervention for the debilitating fatigue suffered by many multiple sclerosis patients, thus significantly improving their level of independence in activities of daily living. © 2017 John Wiley & Sons Ltd.
New Noble Gas Studies on Popping Rocks from the Mid-Atlantic Ridge near 14°N
NASA Astrophysics Data System (ADS)
Kurz, M. D.; Curtice, J.; Jones, M.; Péron, S.; Wanless, V. D.; Mittelstaedt, E. L.; Soule, S. A.; Klein, F.; Fornari, D. J.
2017-12-01
New Popping Rocks were recovered in situ on the Mid-Atlantic Ridge (MAR) near 13.77° N, using HOV Alvin on cruise AT33-03 in 2016 on RV Atlantis. We report new helium, neon, argon, and CO2 step-crushing measurements on a subset of the glass samples, with a focus on a new procedure to collect seafloor samples with minimal exposure to air. Glassy seafloor basalts were collected in sealed containers using the Alvin mechanical arm and transported to the surface without atmospheric exposure. On the ship, the seawater was drained, the volcanic glass was transferred to stainless steel ultra-high-vacuum containers (in an oxygen-free glove box), which were then evacuated using a turbo-molecular pump and sealed for transport under vacuum. All processing was carried out under a nitrogen atmosphere. A control sample was collected from each pillow outcrop and processed normally in air. The preliminary step-crushing measurements show that the anaerobically collected samples have systematically higher 20Ne/22Ne, 21Ne/22Ne and 40Ar/36Ar than the control samples. Helium abundances and isotopes are consistent between anaerobically collected samples and control samples. These results suggest that minimizing atmospheric exposure during sample processing can significantly reduce air contamination for heavy noble gases, providing a new option for seafloor sampling. Higher vesicle abundances appear to yield a greater difference in neon and argon isotopes between the anaerobic and control samples, suggesting that atmospheric contamination is related to vesicle abundance, possibly through micro-fractures. The new data show variability in the maximum mantle neon and argon isotopic compositions, and abundance ratios, suggesting that the samples experienced variable outgassing prior to eruption, and may represent different phases of a single eruption, or multiple eruptions.
Sample Acquisition and Handling System from a Remote Platform
NASA Technical Reports Server (NTRS)
Badescu, Mircea; Sherrit, Stewart; Jones, Jack A.
2011-01-01
A system has been developed to acquire and handle samples from a suspended remote platform. The system includes a penetrator, a penetrator deployment mechanism, and a sample handler. A gravity-driven harpoon sampler was used for the system, but other solutions can be used to supply the penetration energy, such as pyrotechnic, pressurized gas, or springs. The deployment mechanism includes a line that is attached to the penetrator, a spool for reeling in the line, and a line engagement control mechanism. The penetrator has removable tips that can collect liquid, ice, or solid samples. The handling mechanism consists of a carousel that can store a series of identical or different tips, assist in penetrator reconfiguration for multiple sample acquisition, and deliver the sample to a series of instruments for analysis. The carousel sample handling system was combined with a brassboard reeling mechanism and a penetrator with removable tips. It can attach the removable tip to the penetrator, release and retrieve the penetrator, remove the tip, and present it to multiple instrument stations. The penetrator can be remotely deployed from an aerobot, penetrate and collect the sample, and be retrieved with the sample to the aerobot. The penetrator with removable tips includes sample interrogation windows and a sample retainment spring for unconsolidated samples. The line engagement motor can be used to control the penetrator release and reeling engagement, and to evenly distribute the line on the spool by rocking between left and right ends of the spool. When the arm with the guiding ring is aligned with the spool axis, the line is free to unwind from the spool without rotating the spool. When the arm is perpendicular to the spool axis, the line can move only if the spool rotates.
Peterson, David A.; Zumberge, Jeremy R.
2006-01-01
Samples of benthic macroinvertebrates were collected side-by-side from riffles at 12 stream sites in Wyoming, Colorado, and Montana during 2000-2001, following protocols established by the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program and the U.S. Environmental Protection Agency Environmental Monitoring and Assessment Program (EMAP). Samples from riffles were collected following NAWQA protocols, using a sampler with 425-micron net mesh-opening size from a total area of 1.25 m2 per sample in multiple riffles. Samples also were collected following EMAP protocols, using a sampler with 500-micron net mesh-opening size from a total area of 0.72 m2 per sample in multiple riffles. The taxonomic identification and enumeration of the samples followed procedures established for each program. Benthic macroinvertebrate community structure was compared between the data sets using individual metrics, a multimetric index, and multivariate analysis. Comparisons between the macroinvertebrate community structures were made after sequentially adjusting both data sets for: (1) ambiguous taxa, (2) taxonomic inconsistencies, and (3) differences in laboratory subsampling. After removal of ambiguous taxa, pair-wise differences in total taxa richness and Ephemeroptera taxa richness were statistically significant (p < 0.05). Differences between the data sets generally were not significant for richness of other taxa, tolerant taxa, semi-voltine taxa, functional feeding groups, diversity, and dominance. Sample scores calculated using the Wyoming Stream Integrity Index were not significantly different between the two data sets. After reconciling both data sets for taxonomic inconsistencies, total taxa richness and Ephemeroptera taxa richness remained significantly different between the data sets. After adjusting the data for differences in laboratory subsampling, the differences in taxa richness were no longer significant. Bray-Curtis similarity coefficients and non-metric multi-dimensional scaling were used to examine macroinvertebrate community structure. Similarity in community structure between sites was affected to a greater extent by taxa reconciliation than by adjustment for subsampling.
Tansel, Berrin; Surita, Sharon C
2016-06-01
Siloxane levels in biogas can jeopardize the warranties of the engines used at the biogas to energy facilities. The chemical structure of siloxanes consists of silicon and oxygen atoms, alternating in position, with hydrocarbon groups attached to the silicon side chain. Siloxanes can be either in cyclic (D) or linear (L) configuration and referred with a letter corresponding to their structure followed by a number corresponding to the number of silicon atoms present. When siloxanes are burned, the hydrocarbon fraction is lost and silicon is converted to silicates. The purpose of this study was to evaluate the adequacy of activated carbon gas samplers for quantitative analysis of siloxanes in biogas samples. Biogas samples were collected from a landfill and an anaerobic digester using multiple carbon sorbent tubes assembled in series. One set of samples was collected for 30min (sampling 6-L gas), and the second set was collected for 60min (sampling 12-L gas). Carbon particles were thermally desorbed and analyzed by Gas Chromatography Mass Spectrometry (GC/MS). The results showed that biogas sampling using a single tube would not adequately capture octamethyltrisiloxane (L3), hexamethylcyclotrisiloxane (D3), octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5) and dodecamethylcyclohexasiloxane (D6). Even with 4 tubes were used in series, D5 was not captured effectively. The single sorbent tube sampling method was adequate only for capturing trimethylsilanol (TMS) and hexamethyldisiloxane (L2). Affinity of siloxanes for activated carbon decreased with increasing molecular weight. Using multiple carbon sorbent tubes in series can be an appropriate method for developing a standard procedure for determining siloxane levels for low molecular weight siloxanes (up to D3). Appropriate quality assurance and quality control procedures should be developed for adequately quantifying the levels of the higher molecular weight siloxanes in biogas with sorbent tubes. Copyright © 2016 Elsevier Ltd. All rights reserved.
Catch me if you can: Comparing ballast water sampling skids to traditional net sampling
NASA Astrophysics Data System (ADS)
Bradie, Johanna; Gianoli, Claudio; Linley, Robert Dallas; Schillak, Lothar; Schneider, Gerd; Stehouwer, Peter; Bailey, Sarah
2018-03-01
With the recent ratification of the International Convention for the Control and Management of Ships' Ballast Water and Sediments, 2004, it will soon be necessary to assess ships for compliance with ballast water discharge standards. Sampling skids that allow the efficient collection of ballast water samples in a compact space have been developed for this purpose. We ran 22 trials on board the RV Meteor from June 4-15, 2015 to evaluate the performance of three ballast water sampling devices (traditional plankton net, Triton sampling skid, SGS sampling skid) for three organism size classes: ≥ 50 μm, ≥ 10 μm to < 50 μm, and < 10 μm. Natural sea water was run through the ballast water system and untreated samples were collected using paired sampling devices. Collected samples were analyzed in parallel by multiple analysts using several different analytic methods to quantify organism concentrations. To determine whether there were differences in the number of viable organisms collected across sampling devices, results were standardized and statistically treated to filter out other sources of variability, resulting in an outcome variable representing the mean difference in measurements that can be attributed to sampling devices. These results were tested for significance using pairwise Tukey contrasts. Differences in organism concentrations were found in 50% of comparisons between sampling skids and the plankton net for ≥ 50 μm, and ≥ 10 μm to < 50 μm size classes, with net samples containing either higher or lower densities. There were no differences for < 10 μm organisms. Future work will be required to explicitly examine the potential effects of flow velocity, sampling duration, sampled volume, and organism concentrations on sampling device performance.
NASA Technical Reports Server (NTRS)
Roman, Monserrate C.; Jones, Kathy U.; Oubre, Cherie M.; Castro, Victoria; Ott, Mark C.; Birmele, Michele; Venkateswaran, Kasthuri J.; Vaishampayan, Parag A.
2013-01-01
Current methods for microbial detection: a) Labor & time intensive cultivation-based approaches that can fail to detect or characterize all cells present. b) Requires collection of samples on orbit and transportation back to ground for analysis. Disadvantages to current detection methods: a) Unable to perform quick and reliable detection on orbit. b) Lengthy sampling intervals. c) No microbe identification.
Climate Change Mitigation: Can the U.S. Intelligence Community Help?
2013-06-01
satellite sensors to establish the concentration of atmospheric CO2 parts per million (ppm mole fraction) in samples collected at multiple...measurements. Spatial sampling density, the number of sensors or—in the case of satellite imagery the number and resolution of the images—likewise influences...Somewhat paradoxically, sensor accuracy from either remote ( satellites ) or in situ sensors is an important consideration, but it must also be evaluated
Refining lunar impact chronology through high spatial resolution 40Ar/39Ar dating of impact melts
Mercer, Cameron M.; Young, Kelsey E.; Weirich, John R.; Hodges, Kip V.; Jolliff, Bradley L.; Wartho, Jo-Anne; van Soest, Matthijs C.
2015-01-01
Quantitative constraints on the ages of melt-forming impact events on the Moon are based primarily on isotope geochronology of returned samples. However, interpreting the results of such studies can often be difficult because the provenance region of any sample returned from the lunar surface may have experienced multiple impact events over the course of billions of years of bombardment. We illustrate this problem with new laser microprobe 40Ar/39Ar data for two Apollo 17 impact melt breccias. Whereas one sample yields a straightforward result, indicating a single melt-forming event at ca. 3.83 Ga, data from the other sample document multiple impact melt–forming events between ca. 3.81 Ga and at least as young as ca. 3.27 Ga. Notably, published zircon U/Pb data indicate the existence of even older melt products in the same sample. The revelation of multiple impact events through 40Ar/39Ar geochronology is likely not to have been possible using standard incremental heating methods alone, demonstrating the complementarity of the laser microprobe technique. Evidence for 3.83 Ga to 3.81 Ga melt components in these samples reinforces emerging interpretations that Apollo 17 impact breccia samples include a significant component of ejecta from the Imbrium basin impact. Collectively, our results underscore the need to quantitatively resolve the ages of different melt generations from multiple samples to improve our current understanding of the lunar impact record, and to establish the absolute ages of important impact structures encountered during future exploration missions in the inner Solar System. PMID:26601128
Mercer, Cameron M; Young, Kelsey E; Weirich, John R; Hodges, Kip V; Jolliff, Bradley L; Wartho, Jo-Anne; van Soest, Matthijs C
2015-02-01
Quantitative constraints on the ages of melt-forming impact events on the Moon are based primarily on isotope geochronology of returned samples. However, interpreting the results of such studies can often be difficult because the provenance region of any sample returned from the lunar surface may have experienced multiple impact events over the course of billions of years of bombardment. We illustrate this problem with new laser microprobe (40)Ar/(39)Ar data for two Apollo 17 impact melt breccias. Whereas one sample yields a straightforward result, indicating a single melt-forming event at ca. 3.83 Ga, data from the other sample document multiple impact melt-forming events between ca. 3.81 Ga and at least as young as ca. 3.27 Ga. Notably, published zircon U/Pb data indicate the existence of even older melt products in the same sample. The revelation of multiple impact events through (40)Ar/(39)Ar geochronology is likely not to have been possible using standard incremental heating methods alone, demonstrating the complementarity of the laser microprobe technique. Evidence for 3.83 Ga to 3.81 Ga melt components in these samples reinforces emerging interpretations that Apollo 17 impact breccia samples include a significant component of ejecta from the Imbrium basin impact. Collectively, our results underscore the need to quantitatively resolve the ages of different melt generations from multiple samples to improve our current understanding of the lunar impact record, and to establish the absolute ages of important impact structures encountered during future exploration missions in the inner Solar System.
Validating a biometric authentication system: sample size requirements.
Dass, Sarat C; Zhu, Yongfang; Jain, Anil K
2006-12-01
Authentication systems based on biometric features (e.g., fingerprint impressions, iris scans, human face images, etc.) are increasingly gaining widespread use and popularity. Often, vendors and owners of these commercial biometric systems claim impressive performance that is estimated based on some proprietary data. In such situations, there is a need to independently validate the claimed performance levels. System performance is typically evaluated by collecting biometric templates from n different subjects, and for convenience, acquiring multiple instances of the biometric for each of the n subjects. Very little work has been done in 1) constructing confidence regions based on the ROC curve for validating the claimed performance levels and 2) determining the required number of biometric samples needed to establish confidence regions of prespecified width for the ROC curve. To simplify the analysis that address these two problems, several previous studies have assumed that multiple acquisitions of the biometric entity are statistically independent. This assumption is too restrictive and is generally not valid. We have developed a validation technique based on multivariate copula models for correlated biometric acquisitions. Based on the same model, we also determine the minimum number of samples required to achieve confidence bands of desired width for the ROC curve. We illustrate the estimation of the confidence bands as well as the required number of biometric samples using a fingerprint matching system that is applied on samples collected from a small population.
Daily sodium and potassium excretion can be estimated by scheduled spot urine collections.
Doenyas-Barak, Keren; Beberashvili, Ilia; Bar-Chaim, Adina; Averbukh, Zhan; Vogel, Ofir; Efrati, Shai
2015-01-01
The evaluation of sodium and potassium intake is part of the optimal management of hypertension, metabolic syndrome, renal stones, and other conditions. To date, no convenient method for its evaluation exists, as the gold standard method of 24-hour urine collection is cumbersome and often incorrectly performed, and methods that use spot or shorter collections are not accurate enough to replace the gold standard. The aim of this study was to evaluate the correlation and agreement between a new method that uses multiple-scheduled spot urine collection and the gold standard method of 24-hour urine collection. The urine sodium or potassium to creatinine ratios were determined for four scheduled spot urine samples. The mean ratios of the four spot samples and the ratios of each of the single spot samples were corrected for estimated creatinine excretion and compared to the gold standard. A significant linear correlation was demonstrated between the 24-hour urinary solute excretions and estimated excretion evaluated by any of the scheduled spot urine samples. The correlation of the mean of the four spots was better than for any of the single spots. Bland-Altman plots showed that the differences between these measurements were within the limits of agreement. Four scheduled spot urine samples can be used as a convenient method for estimation of 24-hour sodium or potassium excretion. © 2015 S. Karger AG, Basel.
AutoDrug: fully automated macromolecular crystallography workflows for fragment-based drug discovery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsai, Yingssu; Stanford University, 333 Campus Drive, Mudd Building, Stanford, CA 94305-5080; McPhillips, Scott E.
New software has been developed for automating the experimental and data-processing stages of fragment-based drug discovery at a macromolecular crystallography beamline. A new workflow-automation framework orchestrates beamline-control and data-analysis software while organizing results from multiple samples. AutoDrug is software based upon the scientific workflow paradigm that integrates the Stanford Synchrotron Radiation Lightsource macromolecular crystallography beamlines and third-party processing software to automate the crystallography steps of the fragment-based drug-discovery process. AutoDrug screens a cassette of fragment-soaked crystals, selects crystals for data collection based on screening results and user-specified criteria and determines optimal data-collection strategies. It then collects and processes diffraction data,more » performs molecular replacement using provided models and detects electron density that is likely to arise from bound fragments. All processes are fully automated, i.e. are performed without user interaction or supervision. Samples can be screened in groups corresponding to particular proteins, crystal forms and/or soaking conditions. A single AutoDrug run is only limited by the capacity of the sample-storage dewar at the beamline: currently 288 samples. AutoDrug was developed in conjunction with RestFlow, a new scientific workflow-automation framework. RestFlow simplifies the design of AutoDrug by managing the flow of data and the organization of results and by orchestrating the execution of computational pipeline steps. It also simplifies the execution and interaction of third-party programs and the beamline-control system. Modeling AutoDrug as a scientific workflow enables multiple variants that meet the requirements of different user groups to be developed and supported. A workflow tailored to mimic the crystallography stages comprising the drug-discovery pipeline of CoCrystal Discovery Inc. has been deployed and successfully demonstrated. This workflow was run once on the same 96 samples that the group had examined manually and the workflow cycled successfully through all of the samples, collected data from the same samples that were selected manually and located the same peaks of unmodeled density in the resulting difference Fourier maps.« less
Olives, Casey; Valadez, Joseph J; Brooker, Simon J; Pagano, Marcello
2012-01-01
Originally a binary classifier, Lot Quality Assurance Sampling (LQAS) has proven to be a useful tool for classification of the prevalence of Schistosoma mansoni into multiple categories (≤10%, >10 and <50%, ≥50%), and semi-curtailed sampling has been shown to effectively reduce the number of observations needed to reach a decision. To date the statistical underpinnings for Multiple Category-LQAS (MC-LQAS) have not received full treatment. We explore the analytical properties of MC-LQAS, and validate its use for the classification of S. mansoni prevalence in multiple settings in East Africa. We outline MC-LQAS design principles and formulae for operating characteristic curves. In addition, we derive the average sample number for MC-LQAS when utilizing semi-curtailed sampling and introduce curtailed sampling in this setting. We also assess the performance of MC-LQAS designs with maximum sample sizes of n=15 and n=25 via a weighted kappa-statistic using S. mansoni data collected in 388 schools from four studies in East Africa. Overall performance of MC-LQAS classification was high (kappa-statistic of 0.87). In three of the studies, the kappa-statistic for a design with n=15 was greater than 0.75. In the fourth study, where these designs performed poorly (kappa-statistic less than 0.50), the majority of observations fell in regions where potential error is known to be high. Employment of semi-curtailed and curtailed sampling further reduced the sample size by as many as 0.5 and 3.5 observations per school, respectively, without increasing classification error. This work provides the needed analytics to understand the properties of MC-LQAS for assessing the prevalance of S. mansoni and shows that in most settings a sample size of 15 children provides a reliable classification of schools.
A review of international biobanks and networks: success factors and key benchmarks.
Vaught, Jim; Kelly, Andrea; Hewitt, Robert
2009-09-01
Biobanks and biobanking networks are involved in varying degrees in the collection, processing, storage, and dissemination of biological specimens. This review outlines the approaches that 16 of the largest biobanks and biobanking networks in Europe, North America, Australia, and Asia have taken to collecting and distributing human research specimens and managing scientific initiatives while covering operating costs. Many are small operations that exist as either a single or a few freezers in a research laboratory, hospital clinical laboratory, or pathology suite. Larger academic and commercial biobanks operate to support large clinical and epidemiological studies. Operational and business models depend on the medical and research missions of their institutions and home countries. Some national biobanks operate with a centralized physical biobank that accepts samples from multiple locations. Others operate under a "federated" model where each institution maintains its own collections but agrees to list them on a central shared database. Some collections are "project-driven" meaning that specimens are collected and distributed to answer specific research questions. "General" collections are those that exist to establish a reference collection, that is, not to meet particular research goals but to be available to respond to multiple requests for an assortment of research uses. These individual and networked biobanking systems operate under a variety of business models, usually incorporating some form of partial cost recovery, while requiring at least partial public or government funding. Each has a well-defined biospecimen-access policy in place that specifies requirements that must be met-such as ethical clearance and the expertise to perform the proposed experiments-to obtain samples for research. The success of all of these biobanking models depends on a variety of factors including well-defined goals, a solid business plan, and specimen collections that are developed according to strict quality and operational controls.
Reproducibility of urinary biomarkers in multiple 24-h urine samples.
Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C
2017-01-01
Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses' Health Study), NHSII (Nurses' Health Study II), and Health Professionals Follow-Up Study. In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. © 2017 American Society for Nutrition.
Reproducibility of urinary biomarkers in multiple 24-h urine samples123
Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C
2017-01-01
Background: Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. Objective: We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. Design: We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses’ Health Study), NHSII (Nurses’ Health Study II), and Health Professionals Follow-Up Study. Results: In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. Conclusions: These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. PMID:28049663
Persistence of Multiple Genetic Lineages within Intrahost Populations of Ross River Virus▿
Liu, Wen J.; Rourke, Michelle F.; Holmes, Edward C.; Aaskov, John G.
2011-01-01
We examined the structure and extent of genetic diversity in intrahost populations of Ross River virus (RRV) in samples from six human patients, focusing on the nonstructural (nsP3) and structural (E2) protein genes. Strikingly, although the samples were collected from contrasting ecological settings 3,000 kilometers apart in Australia, we observed multiple viral lineages in four of the six individuals, which is indicative of widespread mixed infections. In addition, a comparison with previously published RRV sequences revealed that these distinct lineages have been in circulation for at least 5 years, and we were able to document their long-term persistence over extensive geographical distances. PMID:21430052
Cordón, G Pérez; Prados, A Hitos; Romero, D; Moreno, M Sánchez; Pontes, A; Osuna, A; Rosales, M J
2009-11-12
Birds from the Almuñecar ornithological garden (Granada, Spain) were surveyed from June 2006 to May 2007 to establish programmes to prevent, control, and treat intestinal and haematic parasites. A total of 984 faecal samples and 41 samples of blood were collected from Psittacidae, Cacatuidae, Phasianidae, and Anatidae. One or more intestinal parasites were identified in 51.6% of the samples. Blood parasites were found in 26.8% of the birds examined. The most frequent pathogenic endoparasites were coccidians, such as Cyclospora sp. (4.5%), Eimeria sp. (4.1%) and Isospora sp. (2%) and helminths such as Capillaria sp. (10. 1%), Ascaridia sp. (4.9%) and Heterakis gallinarum (4.9%). All the parasites varied with season but the most were found year round. Multiple parasitic infections by intestinal parasites were common, with 196 of 984 faecal samples having 2-5 intestinal parasites. The most frequent cases of multiple parasitism were Blastocystis plus Entamoeba sp. and Blastocystis plus Cyclospora sp. The haematic protozoa detected were Haemoproteus sp. (17%) and Plasmodium sp. (7.3%). Multiple parasitism by Haemoproteus sp. and Plasmodium sp. was detected in 1 sample of Gallus gallus. After each sampling, some of the affected animals were treated according to our results, and the corresponding programmes of prevention and control were designed.
Espín, S; García-Fernández, A J; Herzke, D; Shore, R F; van Hattum, B; Martínez-López, E; Coeurdassier, M; Eulaers, I; Fritsch, C; Gómez-Ramírez, P; Jaspers, V L B; Krone, O; Duke, G; Helander, B; Mateo, R; Movalli, P; Sonne, C; van den Brink, N W
2016-05-01
Biomonitoring using birds of prey as sentinel species has been mooted as a way to evaluate the success of European Union directives that are designed to protect people and the environment across Europe from industrial contaminants and pesticides. No such pan-European evaluation currently exists. Coordination of such large scale monitoring would require harmonisation across multiple countries of the types of samples collected and analysed-matrices vary in the ease with which they can be collected and the information they provide. We report the first ever pan-European assessment of which raptor samples are collected across Europe and review their suitability for biomonitoring. Currently, some 182 monitoring programmes across 33 European countries collect a variety of raptor samples, and we discuss the relative merits of each for monitoring current priority and emerging compounds. Of the matrices collected, blood and liver are used most extensively for quantifying trends in recent and longer-term contaminant exposure, respectively. These matrices are potentially the most effective for pan-European biomonitoring but are not so widely and frequently collected as others. We found that failed eggs and feathers are the most widely collected samples. Because of this ubiquity, they may provide the best opportunities for widescale biomonitoring, although neither is suitable for all compounds. We advocate piloting pan-European monitoring of selected priority compounds using these matrices and developing read-across approaches to accommodate any effects that trophic pathway and species differences in accumulation may have on our ability to track environmental trends in contaminants.
Fecal shedding of Salmonella in exotic felids.
Clyde, V L; Ramsay, E C; Bemis, D A
1997-06-01
Two collections of exotic felids were screened for the presence of Salmonella by selective fecal culture utilizing selenite broth and Hektoen enteric agar. In > 90% of the samples, Salmonella was isolated from a single culture. A commercial horsemeat-based diet was fed in both collections, and one collection also was fed raw chicken. Salmonella was cultured from the raw chicken and the horsemeat diet for both collections. Multiple Salmonella serotypes were identified, with S. typhimurium and S. typhimurium (copenhagen) isolated most frequently. Approximately half of the Salmonella isolates demonstrated multiple antibiotic resistance. The ability to harbor Salmonella as normal nonpathogenic bacteria of the gastrointestinal tract may be a physiological adaptation to carnivory. The high rate of fecal shedding of Salmonella in healthy individuals clouds the interpretation of a positive fecal culture in an ill felid, or one with diarrhea. All zoo employees having contact with cat feces or raw diets have a high rate of occupational exposure to Salmonella and should exercise appropriate hygienic precautions.
A line-scan hyperspectral Raman system for spatially offset Raman spectroscopy
USDA-ARS?s Scientific Manuscript database
Conventional methods of spatially offset Raman spectroscopy (SORS) typically use single-fiber optical measurement probes to slowly and incrementally collect a series of spatially offset point measurements moving away from the laser excitation point on the sample surface, or arrays of multiple fiber ...
The microbial community structure was investigated from bulk phase water samples of multiple collection sites from two service areas within the Cincinnati drinking water distribution system (DWDS). Each area is associated with a different primary source of water (i.e., groundwat...
CoINcIDE: A framework for discovery of patient subtypes across multiple datasets.
Planey, Catherine R; Gevaert, Olivier
2016-03-09
Patient disease subtypes have the potential to transform personalized medicine. However, many patient subtypes derived from unsupervised clustering analyses on high-dimensional datasets are not replicable across multiple datasets, limiting their clinical utility. We present CoINcIDE, a novel methodological framework for the discovery of patient subtypes across multiple datasets that requires no between-dataset transformations. We also present a high-quality database collection, curatedBreastData, with over 2,500 breast cancer gene expression samples. We use CoINcIDE to discover novel breast and ovarian cancer subtypes with prognostic significance and novel hypothesized ovarian therapeutic targets across multiple datasets. CoINcIDE and curatedBreastData are available as R packages.
NASA Astrophysics Data System (ADS)
Moyer, C. L.; Davis, R. E.; Curtis, A. C.; Rassa, A. C.
2007-12-01
Loihi Seamount is an active submarine volcano that marks the southernmost extent of the Hawaiian hotspot. Loihi rises over 3000 meters from the seafloor and summits nearly 1000 meters below sea level. Hydrothermal activity was discovered at Loihi in 1987, yielding diffuse vent effluent (Tmax 37°C) with associated high CO2 and Fe(II) concentrations and luxuriant microbial mats located near the summit of the volcano. Loihi erupted most recently in 1996 forming a new 300 meter deep caldera (Pele's Pit) with hydrothermal venting up to 200°C. Pele's Pit has cooled and now contains multiple hydrothermal vents with hydrothermal fluids ranging from 8-58°C with concentrations of Fe(II) remaining between 50 and 750 μM. Community fingerprints from over 75 microbial mat samples have now been collected from Loihi Seamount from 1993 to 2006, with temperatures ranging from ambient (~4°C) up to nearly ~200°C. These samples were analyzed using Pearson product-moment coupled with UPGMA cluster analysis of terminal- restriction fragment length polymorphisms (T-RFLP) coupled with traditional clone library and sequence analysis to identify the primary populations within each community. These mat samples form two distinct community clusters (Loihi Cluster Group 1 and Group 2) representing a combined 90% of all mat samples collected. Loihi Cluster Group 1 is by far the largest group (n = 45) and contains the most mat samples collected over time. Group 1 is dominated by phylotypes closely related to the recently described zeta- Proteobacteria that includes the type strain Mariprofundus ferrooxydans, an obligately lithotrophic, Fe-oxidizing bacterium. Loihi Cluster Group 2 is comprised of only post-eruption communities (n = 18) that generally contain greater diversity (in terms of richness) than Group 1 communities. Group 2 communities are primarily dominated by a unique array of phylotypes belonging to the Nitrospira division and by the class epsilon- Proteobacteria, including many putative sulphur-oxidizing bacteria. Interestingly, we have recently witnessed a shift away from the Group 2 communities back to the Group 1 communities. Only 2 of 11 microbial mat samples collected in 2004 exhibited the Group 2 community structure. All 10 of the mat samples collected in 2006 from multiple locations exhibited the Group 1 community structure, indicating a reduced overall diversity within Pele's Pit and a return to the microbial mats being dominated by Fe-oxidizing bacteria.
NASA Technical Reports Server (NTRS)
Guinn, Joseph R.; Kerridge, Stuart J.; Wilson, Roby S.
2012-01-01
Mars sample return is a major scientific goal of the 2011 US National Research Council Decadal Survey for Planetary Science. Toward achievement of this goal, recent architecture studies have focused on several mission concept options for the 2018/2020 Mars launch opportunities. Mars orbiters play multiple roles in these architectures such as: relay, landing site identification/selection/certification, collection of on-going or new measurements to fill knowledge gaps, and in-orbit collection and transportation of samples from Mars to Earth. This paper reviews orbiter concepts that combine these roles and describes a novel family of relay orbits optimized for surface operations support. Additionally, these roles provide an intersection of objectives for long term NASA science, human exploration, technology development and international collaboration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McAllister, R.A.; Moore, W.H.; Rice, J.
1989-04-01
From October, 1987 to October, 1988 samples of ambient air were collected at 19 sites in the eastern part of the U.S. Every 12 days, air was integrated over 24-hour periods into passivated stainless steel canisters. Simultaneously, air was drawn through cartridges containing dinitrophenylhydrazine to collect carbonyl compounds. The samples were analyzed at a central laboratory for a total of 37 halogenated and aromatic hydrocarbons, formaldehyde, acetaldehyde, and other oxygenated species. The hydrocarbon species were analyzed by gas chromatography/multiple detectors and gas chromatography/mass spectrometry, while the carbonyl species were analyzed by liquid chromatography. An extensive quality assurance program was carriedmore » on to secure high quality data. Complete data for all the hydrocarbon samples are presented in the report.« less
Improved explosive collection and detection with rationally assembled surface sampling materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chouyyok, Wilaiwan; Bays, J. Timothy; Gerasimenko, Aleksandr A.
Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple usesmore » of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sirunyan, Albert M; et al.
The elliptic azimuthal anisotropy coefficient (more » $$v_2$$) is measured for charm (D$^0$) and strange (K$$_\\mathrm{S}^0$$, $$\\Lambda$$, $$\\Xi^-$$, and $$\\Omega^-$$) hadrons, using a data sample of pPb collisions collected by the CMS experiment, at a nucleon-nucleon center-of-mass energy $$\\sqrt{s_{_\\mathrm{NN}}} =$$ 8.16 TeV. A significant positive $$v_2$$ signal from long-range azimuthal correlations is observed for all particle species in high-multiplicity pPb collisions. The measurement represents the first observation of possible long-range collectivity for open heavy flavor hadrons in small systems. The results suggest that charm quarks have a smaller $$v_2$$ than the lighter quarks, probably reflecting a weaker collective behavior. This effect is not seen in the larger PbPb collision system at $$\\sqrt{s_{_\\mathrm{NN}}} =$$ 5.02 TeV, also presented.« less
Developing a technique to master multiplication facts 6 to 9 for year 5 pupils
NASA Astrophysics Data System (ADS)
Ahmat, Norhayati; Mohamed, Nurul Huda; Azmee, Nor Afzalina; Adham, Sarah Mohd
2017-05-01
This study was performed to enhance the mastery of multiplication facts 6 to 9 amongst the year 5 pupils. The samples of this study were 40 pupils of year 5 from one of primary school at Teluk Intan, Perak. The samples were divided into two groups, the control group and the treatment group where each group consists of 20 pupils respectively. In this study, new multiplication facts technique, known as `Teknik Sifir Jari' has been introduced to the treatment group. The objectives of the study are to test the effectiveness of the new technique and to increase multiplication fact fluency among pupils. The instruments that have been used in this study are the achievement tests (pre-test and post-test). The data obtained were collected and analyzed using SPSS version 21.A t-test had also been carried out to test the null hypothesis. The results showed that there was an increment in the students' achievement for the students who were taught using the `Teknik Sifir Jari'. Therefore, the `Teknik Sifir Jari' has proved its effectiveness to support students in mastering multiplication facts.
Miller, Arthur L; Drake, Pamela L; Murphy, Nathaniel C; Cauda, Emanuele G; LeBouf, Ryan F; Markevicius, Gediminas
Miners are exposed to silica-bearing dust which can lead to silicosis, a potentially fatal lung disease. Currently, airborne silica is measured by collecting filter samples and sending them to a laboratory for analysis. Since this may take weeks, a field method is needed to inform decisions aimed at reducing exposures. This study investigates a field-portable Fourier transform infrared (FTIR) method for end-of-shift (EOS) measurement of silica on filter samples. Since the method entails localized analyses, spatial uniformity of dust deposition can affect accuracy and repeatability. The study, therefore, assesses the influence of radial deposition uniformity on the accuracy of the method. Using laboratory-generated Minusil and coal dusts and three different types of sampling systems, multiple sets of filter samples were prepared. All samples were collected in pairs to create parallel sets for training and validation. Silica was measured by FTIR at nine locations across the face of each filter and the data analyzed using a multiple regression analysis technique that compared various models for predicting silica mass on the filters using different numbers of "analysis shots." It was shown that deposition uniformity is independent of particle type (kaolin vs. silica), which suggests the role of aerodynamic separation is negligible. Results also reflected the correlation between the location and number of shots versus the predictive accuracy of the models. The coefficient of variation (CV) for the models when predicting mass of validation samples was 4%-51% depending on the number of points analyzed and the type of sampler used, which affected the uniformity of radial deposition on the filters. It was shown that using a single shot at the center of the filter yielded predictivity adequate for a field method, (93% return, CV approximately 15%) for samples collected with 3-piece cassettes.
Coupe, R H; Manning, M A; Foreman, W T; Goolsby, D A; Majewski, M S
2000-04-05
In April 1995, the US Geological Survey began a study to determine the occurrence and temporal distribution of 49 pesticides and pesticide metabolites in air and rain samples from an urban and an agricultural sampling site in Mississippi. The study was a joint effort between the National Water-Quality Assessment and the Toxic Substances Programs and was part of a larger study examining the occurrence and temporal distribution of pesticides in air and rain in the Mississippi River basin. Concurrent high-volume air and wet-only deposition samples were collected weekly. The air samplers consisted of a glass-fiber filter to collect particles and tandem polyurethane foam plugs to collect gas-phase pesticides. Every rain and air sample collected from the urban and agricultural sites had detectable levels of multiple pesticides. The magnitude of the total concentration was 5-10 times higher at the agricultural site as compared to the urban site. The pesticide with the highest concentration in rain at both sites was methyl parathion. The pesticide with the highest concentration in the air samples from the agricultural site was also methyl parathion, but from the urban site the highest concentration was diazinon followed closely by chlorpyrifos. More than two decades since p,p'-DDT was banned from use in the United States, p,p'-DDE, a metabolite of p,p'-DDT, was detected in every air sample collected from the agricultural site and in more than half of the air samples from the urban site.
Coupe, R.H.; Manning, M.A.; Foreman, W.T.; Goolsby, D.A.; Majewski, M.S.
2000-01-01
In April 1995, the US Geological Survey began a study to determine the occurrence and temporal distribution of 49 pesticides and pesticide metabolites in air and rain samples from an urban and an agricultural sampling site in Mississippi. The study was a joint effort between the National Water-Quality Assessment and the Toxic Substances Programs and was part of a larger study examining the occurrence and temporal distribution of pesticides in air and rain in the Mississippi River basin. Concurrent high-volume air and wet-only deposition samples were collected weekly. The air samplers consisted of a glass-fiber filter to collect particles and tandem polyurethane foam plugs to collect gas-phase pesticides. Every rain and air sample collected from the urban and agricultural sites had detectable levels of multiple pesticides. The magnitude of the total concentration was 5-10 times higher at the agricultural site as compared to the urban site. The pesticide with the highest concentration in rain at both sites was methyl parathion. The pesticide with the highest concentration in the air samples from the agricultural site was also methyl parathion, but from the urban site the highest concentration was diazinon followed closely by chlorpyrifos. More than two decades since p,p'-DDT was banned from use in the United States, p,p'-DDE, a metabolite of p,p'-DDT, was detected in every air sample collected from the agricultural site and in more than half of the air samples from the urban site. Copyright (C) 2000 Elsevier Science B.V.
Mielke, Howard W.; Gonzales, Christopher; Powell, Eric; MielkeJr, Paul W.
2005-01-01
Soil metal surveys were conducted in Baltimore, MD (1976–1979), Minnesota (1981–1988) and most recently, New Orleans, LA (1989-present). The unique characteristic of New Orleans is that it has two surveys; Survey I was completed in 1992 and Survey II was completed in 2000. This paper seeks to determine if there is a perceptible change in the amount of metals during less than a decade that separated these surveys. The Survey I collection was 4,026 samples stratified by 283 census tracts. All samples were collected in residential neighborhoods at least one block from a busy street. The Survey II collection was 5,467 samples stratified by 286 census tracts (plus City Park). The Survey II collection included busy streets as a category of samples. For comparison, the busy street category of 1,078 samples was excluded from Survey II for a total of 4,388 samples. The extraction methods of the two surveys used the same protocol for strength of acid (1 M HNO3), shaker-time (2 hours), and room temperature (~22ºC). However, Survey II differed in amount of sample used in extraction. For Surveys I and II, 4.0g and 0.4g were used respectively. The same ICP-AES was used to measure 8 metals in both surveys. To evaluate the analytical results of the two methods, reference soil samples (n=36) from the Wageningen Evaluating Programs for Analytical Laboratories, International Soil-analytical Exchange (WEPAL; ISE) were used. The relationship between the 4.0 and 0.4 g results were linear and the Survey I results were adjusted for sample:acid ratio. Further evaluation was done by creating interpolated Multiple Metal Accumulation (MMA) maps based on the median MMA for each census tract. A new map was created by dividing Survey II MMA by Survey I MMA. The ratio indicates increases of soil metals in the inner city and decreases of soil metals in the outlying areas of Metropolitan New Orleans. Comparing fresh parent alluvium from the Mississippi River with urban soil metal quantities demonstrates that the soils of New Orleans have undergone a massive accumulation of metals. The preliminary results provide ideas about methods needed to further evaluate the changes between these surveys. PMID:16705833
Fully automatic characterization and data collection from crystals of biological macromolecules.
Svensson, Olof; Malbet-Monaco, Stéphanie; Popov, Alexander; Nurizzo, Didier; Bowler, Matthew W
2015-08-01
Considerable effort is dedicated to evaluating macromolecular crystals at synchrotron sources, even for well established and robust systems. Much of this work is repetitive, and the time spent could be better invested in the interpretation of the results. In order to decrease the need for manual intervention in the most repetitive steps of structural biology projects, initial screening and data collection, a fully automatic system has been developed to mount, locate, centre to the optimal diffraction volume, characterize and, if possible, collect data from multiple cryocooled crystals. Using the capabilities of pixel-array detectors, the system is as fast as a human operator, taking an average of 6 min per sample depending on the sample size and the level of characterization required. Using a fast X-ray-based routine, samples are located and centred systematically at the position of highest diffraction signal and important parameters for sample characterization, such as flux, beam size and crystal volume, are automatically taken into account, ensuring the calculation of optimal data-collection strategies. The system is now in operation at the new ESRF beamline MASSIF-1 and has been used by both industrial and academic users for many different sample types, including crystals of less than 20 µm in the smallest dimension. To date, over 8000 samples have been evaluated on MASSIF-1 without any human intervention.
Correction of elevation offsets in multiple co-located lidar datasets
Thompson, David M.; Dalyander, P. Soupy; Long, Joseph W.; Plant, Nathaniel G.
2017-04-07
IntroductionTopographic elevation data collected with airborne light detection and ranging (lidar) can be used to analyze short- and long-term changes to beach and dune systems. Analysis of multiple lidar datasets at Dauphin Island, Alabama, revealed systematic, island-wide elevation differences on the order of 10s of centimeters (cm) that were not attributable to real-world change and, therefore, were likely to represent systematic sampling offsets. These offsets vary between the datasets, but appear spatially consistent within a given survey. This report describes a method that was developed to identify and correct offsets between lidar datasets collected over the same site at different times so that true elevation changes over time, associated with sediment accumulation or erosion, can be analyzed.
Faruki, Hawazin; Mayhew, Gregory M; Fan, Cheng; Wilkerson, Matthew D; Parker, Scott; Kam-Morgan, Lauren; Eisenberg, Marcia; Horten, Bruce; Hayes, D Neil; Perou, Charles M; Lai-Goldman, Myla
2016-06-01
Context .- A histologic classification of lung cancer subtypes is essential in guiding therapeutic management. Objective .- To complement morphology-based classification of lung tumors, a previously developed lung subtyping panel (LSP) of 57 genes was tested using multiple public fresh-frozen gene-expression data sets and a prospectively collected set of formalin-fixed, paraffin-embedded lung tumor samples. Design .- The LSP gene-expression signature was evaluated in multiple lung cancer gene-expression data sets totaling 2177 patients collected from 4 platforms: Illumina RNAseq (San Diego, California), Agilent (Santa Clara, California) and Affymetrix (Santa Clara) microarrays, and quantitative reverse transcription-polymerase chain reaction. Gene centroids were calculated for each of 3 genomic-defined subtypes: adenocarcinoma, squamous cell carcinoma, and neuroendocrine, the latter of which encompassed both small cell carcinoma and carcinoid. Classification by LSP into 3 subtypes was evaluated in both fresh-frozen and formalin-fixed, paraffin-embedded tumor samples, and agreement with the original morphology-based diagnosis was determined. Results .- The LSP-based classifications demonstrated overall agreement with the original clinical diagnosis ranging from 78% (251 of 322) to 91% (492 of 538 and 869 of 951) in the fresh-frozen public data sets and 84% (65 of 77) in the formalin-fixed, paraffin-embedded data set. The LSP performance was independent of tissue-preservation method and gene-expression platform. Secondary, blinded pathology review of formalin-fixed, paraffin-embedded samples demonstrated concordance of 82% (63 of 77) with the original morphology diagnosis. Conclusions .- The LSP gene-expression signature is a reproducible and objective method for classifying lung tumors and demonstrates good concordance with morphology-based classification across multiple data sets. The LSP panel can supplement morphologic assessment of lung cancers, particularly when classification by standard methods is challenging.
Wegner, S.J.
1989-01-01
Multiple water samples from 115 wells and 3 surface water sites were collected between 1980 and 1988 for the ongoing quality assurance program at the Idaho National Engineering Laboratory. The reported results from the six laboratories involved were analyzed for agreement using descriptive statistics. The constituents and properties included: tritium, plutonium-238, plutonium-239, -240 (undivided), strontium-90, americium-241, cesium-137, total dissolved chromium, selected dissolved trace metals, sodium, chloride, nitrate, selected purgeable organic compounds, and specific conductance. Agreement could not be calculated for purgeable organic compounds, trace metals, some nitrates and blank sample analyses because analytical uncertainties were not consistently reported. However, differences between results for most of these data were calculated. The blank samples were not analyzed for differences. The laboratory results analyzed using descriptive statistics showed a median agreement between all useable data pairs of 95%. (USGS)
Comparison of vaginal microbiota sampling techniques: cytobrush versus swab.
Mitra, Anita; MacIntyre, David A; Mahajan, Vishakha; Lee, Yun S; Smith, Ann; Marchesi, Julian R; Lyons, Deirdre; Bennett, Phillip R; Kyrgiou, Maria
2017-08-29
Evidence suggests the vaginal microbiota (VM) may influence risk of persistent Human Papillomavirus (HPV) infection and cervical carcinogenesis. Established cytology biobanks, typically collected with a cytobrush, constitute a unique resource to study such associations longitudinally. It is plausible that compared to rayon swabs; the most commonly used sampling devices, cytobrushes may disrupt biofilms leading to variation in VM composition. Cervico-vaginal samples were collected with cytobrush and rayon swabs from 30 women with high-grade cervical precancer. Quantitative PCR was used to compare bacterial load and Illumina MiSeq sequencing of the V1-V3 regions of the 16S rRNA gene used to compare VM composition. Cytobrushes collected a higher total bacterial load. Relative abundance of bacterial species was highly comparable between sampling devices (R 2 = 0.993). However, in women with a Lactobacillus-depleted, high-diversity VM, significantly less correlation in relative species abundance was observed between devices when compared to those with a Lactobacillus species-dominant VM (p = 0.0049). Cytobrush and swab sampling provide a comparable VM composition. In a small proportion of cases the cytobrush was able to detect underlying high-diversity community structure, not realized with swab sampling. This study highlights the need to consider sampling devices as potential confounders when comparing multiple studies and datasets.
Principals' Perceptions of Successful Leadership
ERIC Educational Resources Information Center
Childers, Gary L.
2013-01-01
The purposes of this qualitative multiple case study were to determine the catalysts and pathways that caused principals to move from managers to effective leaders. Data were collected through a series of interviews with 4 principals who were selected through a purposeful sampling procedure. The interviews were audio recorded, transcribed, and…
Fathead minnows (Pimephales promelas) were caged for four days at multiple locations upstream and downstream of a wastewater treatment plant (WWTP) discharge into the Maumee River (USA, OH). Grab water samples collected at the same location were extracted using several different ...
School Climate, Principal Support and Collaboration among Portuguese Teachers
ERIC Educational Resources Information Center
Castro Silva, José; Amante, Lúcia; Morgado, José
2017-01-01
This article analyses the relationship between school principal support and teacher collaboration among Portuguese teachers. Data were collected from a random sample of 234 teachers in middle and secondary schools. The use of a combined approach using linear and multiple regression tests concluded that the school principal support, through the…
Size-fractionated particulate matter (PM) samples were collected from six U.S. cities and chemically analyzed as part of the Multiple Air Pollutant Study. Particles were administered to cultured lung cells and the production of three different proinflammatory markers was measured...
ERIC Educational Resources Information Center
Obery, Amanda; Bangert, Arthur
2017-01-01
This study was undertaken to investigate the factors influencing proenvironmental behavior of individuals residing in the Northern Rocky Mountains (N = 267). Measures of relatedness to nature and perceived science knowledge were collected through a convenience sample approach using multiple avenues such as city email lists, organizational…
Conceptual Level of Understanding about Sound Concept: Sample of Fifth Grade Students
ERIC Educational Resources Information Center
Bostan Sarioglan, Ayberk
2016-01-01
In this study, students' conceptual change processes related to the sound concept were examined. Study group was comprises of 325 fifth grade middle school students. Three multiple-choice questions were used as the data collection tool. At the data analysis process "scientific response", "scientifically unacceptable response"…
Classroom-Based Measurement and Portfolio Assessment.
ERIC Educational Resources Information Center
Nolet, Victor
1992-01-01
Portfolio assessment involves collecting multiple forms of data to support inferences about student performance in skill or content areas that cannot be sampled directly by a single measure. Portfolio assessment can help to clarify and individualize instructional goals for regular and special education students as well as suggest research and…
Neuropsychological and Early Maturational Correlates of Intelligence.
ERIC Educational Resources Information Center
Denno, Deborah J.
A study designed to examine biological, sociological, and early maturational correlates of intelligence collected data prospectively, from birth to 15 years of age, on a sample of 987 black children. Multiple indicators of eight independent and three dependent variables were tested in a structural equation model. Altogether, clear sex differences…
A Multiple-Tracer Approach for Identifying Sewage Sources to an Urban Stream System
Hyer, Kenneth Edward
2007-01-01
The presence of human-derived fecal coliform bacteria (sewage) in streams and rivers is recognized as a human health hazard. The source of these human-derived bacteria, however, is often difficult to identify and eliminate, because sewage can be delivered to streams through a variety of mechanisms, such as leaking sanitary sewers or private lateral lines, cross-connected pipes, straight pipes, sewer-line overflows, illicit dumping of septic waste, and vagrancy. A multiple-tracer study was conducted to identify site-specific sources of sewage in Accotink Creek, an urban stream in Fairfax County, Virginia, that is listed on the Commonwealth's priority list of impaired streams for violations of the fecal coliform bacteria standard. Beyond developing this multiple-tracer approach for locating sources of sewage inputs to Accotink Creek, the second objective of the study was to demonstrate how the multiple-tracer approach can be applied to other streams affected by sewage sources. The tracers used in this study were separated into indicator tracers, which are relatively simple and inexpensive to apply, and confirmatory tracers, which are relatively difficult and expensive to analyze. Indicator tracers include fecal coliform bacteria, surfactants, boron, chloride, chloride/bromide ratio, specific conductance, dissolved oxygen, turbidity, and water temperature. Confirmatory tracers include 13 organic compounds that are associated with human waste, including caffeine, cotinine, triclosan, a number of detergent metabolites, several fragrances, and several plasticizers. To identify sources of sewage to Accotink Creek, a detailed investigation of the Accotink Creek main channel, tributaries, and flowing storm drains was undertaken from 2001 to 2004. Sampling was conducted in a series of eight synoptic sampling events, each of which began at the most downstream site and extended upstream through the watershed and into the headwaters of each tributary. Using the synoptic sampling approach, 149 sites were sampled at least one time for indicator tracers; 52 of these sites also were sampled for confirmatory tracers at least one time. Through the analysis of multiple-tracer levels in the synoptic samples, three major sewage sources to the Accotink Creek stream network were identified, and several other minor sewage sources to the Accotink Creek system likely deserve additional investigation. Near the end of the synoptic sampling activities, three additional sampling methods were used to gain better understanding of the potential for sewage sources to the watershed. These additional sampling methods included optical brightener monitoring, intensive stream sampling using automated samplers, and additional sampling of several storm-drain networks. The samples obtained by these methods provided further understanding of possible sewage sources to the streams and a better understanding of the variability in the tracer concentrations at a given sampling site. Collectively, these additional sampling methods were a valuable complement to the synoptic sampling approach that was used for the bulk of this study. The study results provide an approach for local authorities to use in applying a relatively simple and inexpensive collection of tracers to locate sewage sources to streams. Although this multiple-tracer approach is effective in detecting sewage sources to streams, additional research is needed to better detect extremely low-volume sewage sources and better enable local authorities to identify the specific sources of the sewage once it is detected in a stream reach.
Using multiple gears to assess acoustic detectability and biomass of fish species in lake superior
Yule, D.L.; Adams, J.V.; Stockwell, J.D.; Gorman, O.T.
2007-01-01
Recent predator demand and prey supply studies suggest that an annual daytime bottom trawl survey of Lake Superior underestimates prey fish biomass. A multiple-gear (acoustics, bottom trawl, and midwater trawl) nighttime survey has been recommended, but before abandoning a long-term daytime survey the effectiveness of night sampling of important prey species must be verified. We sampled three bottom depths (30, 60, and 120 m) at a Lake Superior site where the fish community included all commercially and ecologically important species. Day and night samples were collected within 48 h at all depths during eight different periods (one new and one full moon period during both early summer and late summer to early fall over 2 years). Biomass of demersal and benthic species was higher in night bottom trawl samples than in day bottom trawl samples. Night acoustic collections showed that pelagic fish typically occupied water cooler than 15°C and light levels less than 0.001 lx. Using biomass in night bottom trawls and acoustic biomass above the bottom trawl path, we calculated an index of acoustic detectability for each species. Ciscoes Coregonus artedi, kiyis C. kiyi, and rainbow smeltOsmerus mordax left the bottom at night, whereas bloaters C. hoyi stayed nearer the bottom. We compared the biomass of important prey species estimated with two survey types: day bottom trawls and night estimates of the entire water column (bottom trawl biomass plus acoustic biomass). The biomass of large ciscoes (>200 mm) was significantly greater when measured at night than when measured during daylight, but the differences for other sizes of important species did not vary significantly by survey type. Nighttime of late summer is a period when conditions for biomass estimation are largely invariant, and all important prey species can be sampled using a multiple-gear approach.
Study of probe-sample distance for biomedical spectra measurement.
Wang, Bowen; Fan, Shuzhen; Li, Lei; Wang, Cong
2011-11-02
Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in designing fiber optic probes for biomedical spectra measurement. This model was in general applicable to probes with single or multiple fibers at an arbitrary incident angle. In order to demonstrate the theory, a fluorescence spectrometer was used to measure the fluorescence of human finger skin at various probe-sample distances. The fluorescence spectrum and the total fluorescence intensity were recorded. The theoretical results show that for single fiber probes, contact measurement always provides the best results. While for multi-fiber probes, there is an optimal probe distance. When a 400- μm excitation fiber is used to deliver the light to the skin and another six 400- μm fibers surrounding the excitation fiber are used to collect the fluorescence signal, the experimental results show that human finger skin has very strong fluorescence between 475 nm and 700 nm under 450 nm excitation. The fluorescence intensity is heavily dependent on the probe-sample distance and there is an optimal probe distance. We investigated a number of probe-sample configurations and found that contact measurement could be the primary choice for single-fiber probes, but was very inefficient for multi-fiber probes. There was an optimal probe-sample distance for multi-fiber probes. By carefully choosing the probe-sample distance, the collection efficiency could be enhanced by 5-10 times. Our experiments demonstrated that the experimental results of the probe-sample distance dependence of collection efficiency in multi-fiber probes were in general agreement with our theory.
Field evaluation of personal sampling methods for multiple bioaerosols.
Wang, Chi-Hsun; Chen, Bean T; Han, Bor-Cheng; Liu, Andrew Chi-Yeu; Hung, Po-Chen; Chen, Chih-Yong; Chao, Hsing Jasmine
2015-01-01
Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC) filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters) and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min). Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols.
Multi-scale occupancy estimation and modelling using multiple detection methods
Nichols, James D.; Bailey, Larissa L.; O'Connell, Allan F.; Talancy, Neil W.; Grant, Evan H. Campbell; Gilbert, Andrew T.; Annand, Elizabeth M.; Husband, Thomas P.; Hines, James E.
2008-01-01
Occupancy estimation and modelling based on detection–nondetection data provide an effective way of exploring change in a species’ distribution across time and space in cases where the species is not always detected with certainty. Today, many monitoring programmes target multiple species, or life stages within a species, requiring the use of multiple detection methods. When multiple methods or devices are used at the same sample sites, animals can be detected by more than one method.We develop occupancy models for multiple detection methods that permit simultaneous use of data from all methods for inference about method-specific detection probabilities. Moreover, the approach permits estimation of occupancy at two spatial scales: the larger scale corresponds to species’ use of a sample unit, whereas the smaller scale corresponds to presence of the species at the local sample station or site.We apply the models to data collected on two different vertebrate species: striped skunks Mephitis mephitis and red salamanders Pseudotriton ruber. For striped skunks, large-scale occupancy estimates were consistent between two sampling seasons. Small-scale occupancy probabilities were slightly lower in the late winter/spring when skunks tend to conserve energy, and movements are limited to males in search of females for breeding. There was strong evidence of method-specific detection probabilities for skunks. As anticipated, large- and small-scale occupancy areas completely overlapped for red salamanders. The analyses provided weak evidence of method-specific detection probabilities for this species.Synthesis and applications. Increasingly, many studies are utilizing multiple detection methods at sampling locations. The modelling approach presented here makes efficient use of detections from multiple methods to estimate occupancy probabilities at two spatial scales and to compare detection probabilities associated with different detection methods. The models can be viewed as another variation of Pollock's robust design and may be applicable to a wide variety of scenarios where species occur in an area but are not always near the sampled locations. The estimation approach is likely to be especially useful in multispecies conservation programmes by providing efficient estimates using multiple detection devices and by providing device-specific detection probability estimates for use in survey design.
Impact of Educational Activities in Reducing Pre-Analytical Laboratory Errors
Al-Ghaithi, Hamed; Pathare, Anil; Al-Mamari, Sahimah; Villacrucis, Rodrigo; Fawaz, Naglaa; Alkindi, Salam
2017-01-01
Objectives Pre-analytic errors during diagnostic laboratory investigations can lead to increased patient morbidity and mortality. This study aimed to ascertain the effect of educational nursing activities on the incidence of pre-analytical errors resulting in non-conforming blood samples. Methods This study was conducted between January 2008 and December 2015. All specimens received at the Haematology Laboratory of the Sultan Qaboos University Hospital, Muscat, Oman, during this period were prospectively collected and analysed. Similar data from 2007 were collected retrospectively and used as a baseline for comparison. Non-conforming samples were defined as either clotted samples, haemolysed samples, use of the wrong anticoagulant, insufficient quantities of blood collected, incorrect/lack of labelling on a sample or lack of delivery of a sample in spite of a sample request. From 2008 onwards, multiple educational training activities directed at the hospital nursing staff and nursing students primarily responsible for blood collection were implemented on a regular basis. Results After initiating corrective measures in 2008, a progressive reduction in the percentage of non-conforming samples was observed from 2009 onwards. Despite a 127.84% increase in the total number of specimens received, there was a significant reduction in non-conforming samples from 0.29% in 2007 to 0.07% in 2015, resulting in an improvement of 75.86% (P <0.050). In particular, specimen identification errors decreased by 0.056%, with a 96.55% improvement. Conclusion Targeted educational activities directed primarily towards hospital nursing staff had a positive impact on the quality of laboratory specimens by significantly reducing pre-analytical errors. PMID:29062553
Impact of Educational Activities in Reducing Pre-Analytical Laboratory Errors: A quality initiative.
Al-Ghaithi, Hamed; Pathare, Anil; Al-Mamari, Sahimah; Villacrucis, Rodrigo; Fawaz, Naglaa; Alkindi, Salam
2017-08-01
Pre-analytic errors during diagnostic laboratory investigations can lead to increased patient morbidity and mortality. This study aimed to ascertain the effect of educational nursing activities on the incidence of pre-analytical errors resulting in non-conforming blood samples. This study was conducted between January 2008 and December 2015. All specimens received at the Haematology Laboratory of the Sultan Qaboos University Hospital, Muscat, Oman, during this period were prospectively collected and analysed. Similar data from 2007 were collected retrospectively and used as a baseline for comparison. Non-conforming samples were defined as either clotted samples, haemolysed samples, use of the wrong anticoagulant, insufficient quantities of blood collected, incorrect/lack of labelling on a sample or lack of delivery of a sample in spite of a sample request. From 2008 onwards, multiple educational training activities directed at the hospital nursing staff and nursing students primarily responsible for blood collection were implemented on a regular basis. After initiating corrective measures in 2008, a progressive reduction in the percentage of non-conforming samples was observed from 2009 onwards. Despite a 127.84% increase in the total number of specimens received, there was a significant reduction in non-conforming samples from 0.29% in 2007 to 0.07% in 2015, resulting in an improvement of 75.86% ( P <0.050). In particular, specimen identification errors decreased by 0.056%, with a 96.55% improvement. Targeted educational activities directed primarily towards hospital nursing staff had a positive impact on the quality of laboratory specimens by significantly reducing pre-analytical errors.
Urban-air-toxics Monitoring Program, 1990
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-06-01
From March 1990 through February 1991 samples of ambient air were collected at 12 sites in the eastern part of the U.S. Every 12 days, air was integrated over 24-hour periods into passivated stainless steel canisters. Simultaneously, air was drawn through cartridges containing dinitrophenylhydrazine to collect carbonyl compounds. The samples were analyzed at a central laboratory for a total of 37 halogenated and aromatic hydrocarbons, formaldehyde, acetaldehyde, and other oxygenated species. The hydrocarbon species were analyzed by gas chromatography/multiple detectors and gas chromatography/mass spectrometry, while the carbonyl species were analyzed by liquid chromatography. Complete data for all the hydrocarbon samplesmore » are presented in the report.« less
NASA Astrophysics Data System (ADS)
Baxter, Lisa K.; Clougherty, Jane E.; Paciorek, Christopher J.; Wright, Rosalind J.; Levy, Jonathan I.
Previous studies have identified associations between traffic-related air pollution and adverse health effects. Most have used measurements from a few central ambient monitors and/or some measure of traffic as indicators of exposure, disregarding spatial variability and factors influencing personal exposure-ambient concentration relationships. This study seeks to utilize publicly available data (i.e., central site monitors, geographic information system, and property assessment data) and questionnaire responses to predict residential indoor concentrations of traffic-related air pollutants for lower socioeconomic status (SES) urban households. As part of a prospective birth cohort study in urban Boston, we collected indoor and outdoor 3-4 day samples of nitrogen dioxide (NO 2) and fine particulate matter (PM 2.5) in 43 low SES residences across multiple seasons from 2003 to 2005. Elemental carbon (EC) concentrations were determined via reflectance analysis. Multiple traffic indicators were derived using Massachusetts Highway Department data and traffic counts collected outside sampling homes. Home characteristics and occupant behaviors were collected via a standardized questionnaire. Additional housing information was collected through property tax records, and ambient concentrations were collected from a centrally located ambient monitor. The contributions of ambient concentrations, local traffic and indoor sources to indoor concentrations were quantified with regression analyses. PM 2.5 was influenced less by local traffic but had significant indoor sources, while EC was associated with traffic and NO 2 with both traffic and indoor sources. Comparing models based on covariate selection using p-values or a Bayesian approach yielded similar results, with traffic density within a 50 m buffer of a home and distance from a truck route as important contributors to indoor levels of NO 2 and EC, respectively. The Bayesian approach also highlighted the uncertanity in the models. We conclude that by utilizing public databases and focused questionnaire data we can identify important predictors of indoor concentrations for multiple air pollutants in a high-risk population.
NASA Astrophysics Data System (ADS)
Prueger, J. H.; Hatfield, J. L.
2015-09-01
Remotely sensed reflectance parameters from corn and soybean surfaces can be correlated to crop production. Surface reflectance of a typical Upper Midwest corn /soybean region in central Iowa across multiple years reveal subtle dynamics in vegetative surface response to a continually varying climate. From 2006 through 2014 remotely sensed data have been acquired over production fields of corn and soybeans in central IA, U.S.A. with the fields alternating between corn and soybeans. The data have been acquired using ground-based radiometers with 16 wavebands covering the visible, near infrared, shortwave infrared wavebands and combined into a series of vegetative indices. These data were collected on clear days with the goal of collecting data at a minimum of once per week from prior to planting until after fall tillage operations. Within each field, five sites were established and sampled during the year to reduce spatial variation and allow for an assessment of changes in the vegetative indices throughout the growing season. Ancillary data collected for each crop included the phenological stage at each sampling date along with biomass sampled at the onset of the reproductive stage and at physiological maturity. Evaluation of the vegetative indices for the different years revealed that patterns were related to weather effects on corn and soybean growth. Remote sensing provides a method to evaluate changes within and among growing seasons to assess crop growth and development as affected by differences in weather variability.
Lanier, William A; Hall, Julia M; Herlihy, Rachel K; Rolfs, Robert T; Wagner, Jennifer M; Smith, Lori H; Hyytia-Trees, Eija K
2011-10-01
In summer 2009, the Utah Department of Health investigated an outbreak of Shiga-toxigenic Escherichia coli (STEC) O157:H7 (O157) illness associated with attendance at multiple rodeos. Patients were interviewed regarding exposures during the week before illness onset. A ground beef traceback investigation was performed. Ground beef samples from patient homes and a grocery store were tested for STEC O157. Rodeo managers were interviewed regarding food vendors present and cattle used at the rodeos. Environmental samples were collected from rodeo grounds. Two-enzyme pulsed-field gel electrophoresis (PFGE) and multiple-locus variable-number tandem repeat analysis (MLVA) were performed on isolates. Fourteen patients with primary STEC O157 illness were reported in this outbreak. Isolates from all patients were indistinguishable by PFGE. Isolates from nine patients had identical MLVA patterns (main outbreak strain), and five had minor differences. Thirteen (93%) patients reported ground beef consumption during the week before illness onset. Results of the ground beef traceback investigation and ground beef sampling were negative. Of 12 primary patients asked specifically about rodeo attendance, all reported having attended a rodeo during the week before illness onset; four rodeos were mentioned. All four rodeos had used bulls from the same cattle supplier. An isolate of STEC O157 identified from a dirt sample collected from the bullpens of one of the attended rodeos was indistinguishable by PFGE and MLVA from the main outbreak strain. Recommendations were provided to rodeo management to keep livestock and manure separate from rodeo attendees. This is the first reported STEC O157 outbreak associated with attendance at multiple rodeos. Public health officials should be aware of the potential for rodeo-associated STEC illness.
Towner, Jonathan S.; Rollin, Pierre E.; Bausch, Daniel G.; Sanchez, Anthony; Crary, Sharon M.; Vincent, Martin; Lee, William F.; Spiropoulou, Christina F.; Ksiazek, Thomas G.; Lukwiya, Mathew; Kaducu, Felix; Downing, Robert; Nichol, Stuart T.
2004-01-01
The largest outbreak on record of Ebola hemorrhagic fever (EHF) occurred in Uganda from August 2000 to January 2001. The outbreak was centered in the Gulu district of northern Uganda, with secondary transmission to other districts. After the initial diagnosis of Sudan ebolavirus by the National Institute for Virology in Johannesburg, South Africa, a temporary diagnostic laboratory was established within the Gulu district at St. Mary's Lacor Hospital. The laboratory used antigen capture and reverse transcription-PCR (RT-PCR) to diagnose Sudan ebolavirus infection in suspect patients. The RT-PCR and antigen-capture diagnostic assays proved very effective for detecting ebolavirus in patient serum, plasma, and whole blood. In samples collected very early in the course of infection, the RT-PCR assay could detect ebolavirus 24 to 48 h prior to detection by antigen capture. More than 1,000 blood samples were collected, with multiple samples obtained from many patients throughout the course of infection. Real-time quantitative RT-PCR was used to determine the viral load in multiple samples from patients with fatal and nonfatal cases, and these data were correlated with the disease outcome. RNA copy levels in patients who died averaged 2 log10 higher than those in patients who survived. Using clinical material from multiple EHF patients, we sequenced the variable region of the glycoprotein. This Sudan ebolavirus strain was not derived from either the earlier Boniface (1976) or Maleo (1979) strain, but it shares a common ancestor with both. Furthermore, both sequence and epidemiologic data are consistent with the outbreak having originated from a single introduction into the human population. PMID:15047846
DNA barcoding the native flowering plants and conifers of Wales.
de Vere, Natasha; Rich, Tim C G; Ford, Col R; Trinder, Sarah A; Long, Charlotte; Moore, Chris W; Satterthwaite, Danielle; Davies, Helena; Allainguillaume, Joel; Ronca, Sandra; Tatarinova, Tatiana; Garbett, Hannah; Walker, Kevin; Wilkinson, Mike J
2012-01-01
We present the first national DNA barcode resource that covers the native flowering plants and conifers for the nation of Wales (1143 species). Using the plant DNA barcode markers rbcL and matK, we have assembled 97.7% coverage for rbcL, 90.2% for matK, and a dual-locus barcode for 89.7% of the native Welsh flora. We have sampled multiple individuals for each species, resulting in 3304 rbcL and 2419 matK sequences. The majority of our samples (85%) are from DNA extracted from herbarium specimens. Recoverability of DNA barcodes is lower using herbarium specimens, compared to freshly collected material, mostly due to lower amplification success, but this is balanced by the increased efficiency of sampling species that have already been collected, identified, and verified by taxonomic experts. The effectiveness of the DNA barcodes for identification (level of discrimination) is assessed using four approaches: the presence of a barcode gap (using pairwise and multiple alignments), formation of monophyletic groups using Neighbour-Joining trees, and sequence similarity in BLASTn searches. These approaches yield similar results, providing relative discrimination levels of 69.4 to 74.9% of all species and 98.6 to 99.8% of genera using both markers. Species discrimination can be further improved using spatially explicit sampling. Mean species discrimination using barcode gap analysis (with a multiple alignment) is 81.6% within 10×10 km squares and 93.3% for 2×2 km squares. Our database of DNA barcodes for Welsh native flowering plants and conifers represents the most complete coverage of any national flora, and offers a valuable platform for a wide range of applications that require accurate species identification.
DNA Barcoding the Native Flowering Plants and Conifers of Wales
de Vere, Natasha; Rich, Tim C. G.; Ford, Col R.; Trinder, Sarah A.; Long, Charlotte; Moore, Chris W.; Satterthwaite, Danielle; Davies, Helena; Allainguillaume, Joel; Ronca, Sandra; Tatarinova, Tatiana; Garbett, Hannah; Walker, Kevin; Wilkinson, Mike J.
2012-01-01
We present the first national DNA barcode resource that covers the native flowering plants and conifers for the nation of Wales (1143 species). Using the plant DNA barcode markers rbcL and matK, we have assembled 97.7% coverage for rbcL, 90.2% for matK, and a dual-locus barcode for 89.7% of the native Welsh flora. We have sampled multiple individuals for each species, resulting in 3304 rbcL and 2419 matK sequences. The majority of our samples (85%) are from DNA extracted from herbarium specimens. Recoverability of DNA barcodes is lower using herbarium specimens, compared to freshly collected material, mostly due to lower amplification success, but this is balanced by the increased efficiency of sampling species that have already been collected, identified, and verified by taxonomic experts. The effectiveness of the DNA barcodes for identification (level of discrimination) is assessed using four approaches: the presence of a barcode gap (using pairwise and multiple alignments), formation of monophyletic groups using Neighbour-Joining trees, and sequence similarity in BLASTn searches. These approaches yield similar results, providing relative discrimination levels of 69.4 to 74.9% of all species and 98.6 to 99.8% of genera using both markers. Species discrimination can be further improved using spatially explicit sampling. Mean species discrimination using barcode gap analysis (with a multiple alignment) is 81.6% within 10×10 km squares and 93.3% for 2×2 km squares. Our database of DNA barcodes for Welsh native flowering plants and conifers represents the most complete coverage of any national flora, and offers a valuable platform for a wide range of applications that require accurate species identification. PMID:22701588
Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio.
Herrington, William; Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah
2016-10-07
Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long-term frozen storage at -80°C, -40°C, and -20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20-499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at -80°C or -40°C but not at -20°C. Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to -40°C or -80°C for 6 months before analysis also seem suitable. Copyright © 2016 by the American Society of Nephrology.
Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio
Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah
2016-01-01
Background and objectives Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Design, setting, participants, & measurements Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long–term frozen storage at −80°C, −40°C, and −20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Results Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20–499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at −80°C or −40°C but not at −20°C. Conclusions Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to −40°C or −80°C for 6 months before analysis also seem suitable. PMID:27654930
Fully automatic characterization and data collection from crystals of biological macromolecules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Svensson, Olof; Malbet-Monaco, Stéphanie; Popov, Alexander
A fully automatic system has been developed that performs X-ray centring and characterization of, and data collection from, large numbers of cryocooled crystals without human intervention. Considerable effort is dedicated to evaluating macromolecular crystals at synchrotron sources, even for well established and robust systems. Much of this work is repetitive, and the time spent could be better invested in the interpretation of the results. In order to decrease the need for manual intervention in the most repetitive steps of structural biology projects, initial screening and data collection, a fully automatic system has been developed to mount, locate, centre to themore » optimal diffraction volume, characterize and, if possible, collect data from multiple cryocooled crystals. Using the capabilities of pixel-array detectors, the system is as fast as a human operator, taking an average of 6 min per sample depending on the sample size and the level of characterization required. Using a fast X-ray-based routine, samples are located and centred systematically at the position of highest diffraction signal and important parameters for sample characterization, such as flux, beam size and crystal volume, are automatically taken into account, ensuring the calculation of optimal data-collection strategies. The system is now in operation at the new ESRF beamline MASSIF-1 and has been used by both industrial and academic users for many different sample types, including crystals of less than 20 µm in the smallest dimension. To date, over 8000 samples have been evaluated on MASSIF-1 without any human intervention.« less
Occurrence of Propionibacterium freudenreichii bacteriophages in swiss cheese.
Gautier, M; Rouault, A; Sommer, P; Briandet, R
1995-01-01
We isolated bacteriophages active against Propionibacterium freudenreichii from 16 of 32 swiss cheese samples. Bacteriophage concentrations ranged from 14 to 7 x 10(5) PFU/g, depending on the sample and the sensitive strain used for detection. Only a few strains, 8 of the 44 strains of P. freudenreichii in our collection, were sensitive. We observed that multiplication of bacteriophages occurred in the cheese loaf during multiplication of propionibacteria in a warm curing room, but it seems that these bacteriophages have no adverse effect on the development of the propionic flora. We also found that sensitive cells, originating from either the starter or the cheese-making milk, were present at a high level (10(9) CFU/g) in the cheese. PMID:7618869
Levecke, Bruno; Brooker, Simon J; Knopp, Stefanie; Steinmann, Peter; Sousa-Figueiredo, Jose Carlos; Stothard, J Russell; Utzinger, Jürg; Vercruysse, Jozef
2014-12-01
It is generally recommended to perform multiple stool examinations in order to improve the diagnostic accuracy when assessing the impact of mass drug administration programmes to control human intestinal worm infections and determining efficacy of the drugs administered. However, the collection and diagnostic work-up of multiple stool samples increases costs and workload. It has been hypothesized that these increased efforts provide more accurate results when infection and drug efficacy are summarized by prevalence (proportion of subjects infected) and cure rate (CR, proportion of infected subjects that become egg-negative after drug administration), respectively, but not when these indicators are expressed in terms of infection intensity and egg reduction rate (ERR). We performed a meta-analysis of six drug efficacy trials and one epidemiological survey. We compared prevalence and intensity of infection, CR and ERR based on collection of one or two stool samples that were processed with single or duplicate Kato-Katz thick smears. We found that the accuracy of prevalence estimates and CR was lowest with the minimal sampling effort, but that this was not the case for estimating infection intensity and ERR. Hence, a single Kato-Katz thick smear is sufficient for reporting infection intensity and ERR following drug treatment.
Predictors of 2,4-dichlorophenoxyacetic acid exposure among herbicide applicators
BHATTI, PARVEEN; BLAIR, AARON; BELL, ERIN M.; ROTHMAN, NATHANIEL; LAN, QING; BARR, DANA B.; NEEDHAM, LARRY L.; PORTENGEN, LUTZEN; FIGGS, LARRY W.; VERMEULEN, ROEL
2009-01-01
To determine the major factors affecting the urinary levels of 2,4-dichlorophenoxyacetic acid (2,4-D) among county noxious weed applicators in Kansas, we used a regression technique that accounted for multiple days of exposure. We collected 136 12-h urine samples from 31 applicators during the course of two spraying seasons (April to August of 1994 and 1995). Using mixed-effects models, we constructed exposure models that related urinary 2,4-D measurements to weighted self-reported work activities from daily diaries collected over 5 to 7 days before the collection of the urine sample. Our primary weights were based on an earlier pharmacokinetic analysis of turf applicators; however, we examined a series of alternative weighting schemes to assess the impact of the specific weights and the number of days before urine sample collection that were considered. The derived models accounting for multiple days of exposure related to a single urine measurement seemed robust with regard to the exact weights, but less to the number of days considered; albeit the determinants from the primary model could be fitted with marginal losses of fit to the data from the other weighting schemes that considered a different numbers of days. In the primary model, the total time of all activities (spraying, mixing, other activities), spraying method, month of observation, application concentration, and wet gloves were significant determinants of urinary 2,4-D concentration and explained 16% of the between-worker variance and 23% of the within-worker variance of urinary 2,4-D levels. As a large proportion of the variance remained unexplained, further studies should be conducted to try to systematically assess other exposure determinants. PMID:19319162
Kondo, Sonoko; Hoar, Bruce R; Villanueva, Veronica; Mandrell, Robert E; Atwill, Edward R
2010-11-01
To evaluate seasonal patterns and risk factors for Escherichia coli O157:H7 in feces in a beef cattle herd and determine strain diversity and transition in E coli over time by use of multiple-locus variable-number tandem-repeat analysis (MLVA) and pulsed-field gel electrophoresis (PFGE). 456 samples of freshly passed feces collected over a 1-year period from cattle in a range-based cow-calf operation located in the foothills of the Sierra Nevada Mountains in California. E coli O157:H7 was recovered from feces by use of immunomagnetic separation and 2 selective media. Virulence factors were detected via reverse transcriptase-PCR assay. Escherichia coli O157:H7 isolates were subtyped with MLVA and PFGE. Prevalence estimates were calculated and significant risk factors determined. A dendrogram was constructed on the basis of results of MLVA typing. Overall prevalence estimate for E coli O157:H7 was 10.5%, with the prevalence lowest during the winter. Mean temperature during the 30 days before collection of samples was significantly associated with prevalence of E coli O157:H7 in feces. Nineteen MLVA and 12 PFGE types were identified. A seasonal pattern was detected for prevalence of E coli O157:H7 in feces collected from beef cattle in California. Subtyping via MLVA and PFGE revealed a diversity of E coli O157:H7 strains in a cow-calf operation and noteworthy turnover of predominant types. Given the importance of accurately determining sources of contamination in investigations of disease outbreaks in humans, MLVA combined with PFGE should be powerful tools for epidemiologists.
The Hawaiian Freshwater Algal Database (HfwADB): a laboratory LIMS and online biodiversity resource
2012-01-01
Background Biodiversity databases serve the important role of highlighting species-level diversity from defined geographical regions. Databases that are specially designed to accommodate the types of data gathered during regional surveys are valuable in allowing full data access and display to researchers not directly involved with the project, while serving as a Laboratory Information Management System (LIMS). The Hawaiian Freshwater Algal Database, or HfwADB, was modified from the Hawaiian Algal Database to showcase non-marine algal specimens collected from the Hawaiian Archipelago by accommodating the additional level of organization required for samples including multiple species. Description The Hawaiian Freshwater Algal Database is a comprehensive and searchable database containing photographs and micrographs of samples and collection sites, geo-referenced collecting information, taxonomic data and standardized DNA sequence data. All data for individual samples are linked through unique 10-digit accession numbers (“Isolate Accession”), the first five of which correspond to the collection site (“Environmental Accession”). Users can search online for sample information by accession number, various levels of taxonomy, habitat or collection site. HfwADB is hosted at the University of Hawaii, and was made publicly accessible in October 2011. At the present time the database houses data for over 2,825 samples of non-marine algae from 1,786 collection sites from the Hawaiian Archipelago. These samples include cyanobacteria, red and green algae and diatoms, as well as lesser representation from some other algal lineages. Conclusions HfwADB is a digital repository that acts as a Laboratory Information Management System for Hawaiian non-marine algal data. Users can interact with the repository through the web to view relevant habitat data (including geo-referenced collection locations) and download images of collection sites, specimen photographs and micrographs, and DNA sequences. It is publicly available at http://algae.manoa.hawaii.edu/hfwadb/. PMID:23095476
Yang, Yang; DeGruttola, Victor
2016-01-01
Traditional resampling-based tests for homogeneity in covariance matrices across multiple groups resample residuals, that is, data centered by group means. These residuals do not share the same second moments when the null hypothesis is false, which makes them difficult to use in the setting of multiple testing. An alternative approach is to resample standardized residuals, data centered by group sample means and standardized by group sample covariance matrices. This approach, however, has been observed to inflate type I error when sample size is small or data are generated from heavy-tailed distributions. We propose to improve this approach by using robust estimation for the first and second moments. We discuss two statistics: the Bartlett statistic and a statistic based on eigen-decomposition of sample covariance matrices. Both statistics can be expressed in terms of standardized errors under the null hypothesis. These methods are extended to test homogeneity in correlation matrices. Using simulation studies, we demonstrate that the robust resampling approach provides comparable or superior performance, relative to traditional approaches, for single testing and reasonable performance for multiple testing. The proposed methods are applied to data collected in an HIV vaccine trial to investigate possible determinants, including vaccine status, vaccine-induced immune response level and viral genotype, of unusual correlation pattern between HIV viral load and CD4 count in newly infected patients. PMID:22740584
Yang, Yang; DeGruttola, Victor
2012-06-22
Traditional resampling-based tests for homogeneity in covariance matrices across multiple groups resample residuals, that is, data centered by group means. These residuals do not share the same second moments when the null hypothesis is false, which makes them difficult to use in the setting of multiple testing. An alternative approach is to resample standardized residuals, data centered by group sample means and standardized by group sample covariance matrices. This approach, however, has been observed to inflate type I error when sample size is small or data are generated from heavy-tailed distributions. We propose to improve this approach by using robust estimation for the first and second moments. We discuss two statistics: the Bartlett statistic and a statistic based on eigen-decomposition of sample covariance matrices. Both statistics can be expressed in terms of standardized errors under the null hypothesis. These methods are extended to test homogeneity in correlation matrices. Using simulation studies, we demonstrate that the robust resampling approach provides comparable or superior performance, relative to traditional approaches, for single testing and reasonable performance for multiple testing. The proposed methods are applied to data collected in an HIV vaccine trial to investigate possible determinants, including vaccine status, vaccine-induced immune response level and viral genotype, of unusual correlation pattern between HIV viral load and CD4 count in newly infected patients.
Vaccarella, Salvatore; Söderlund-Strand, Anna; Franceschi, Silvia; Plummer, Martyn; Dillner, Joakim
2013-01-01
To evaluate the pattern of co-infection of human papillomavirus (HPV) types in both sexes in Sweden. Cell samples from genital swabs, first-void urine, and genital swabs immersed in first-void urine were collected in the present cross-sectional High Throughput HPV Monitoring study. Overall, 31,717 samples from women and 9,949 from men (mean age 25) were tested for 16 HPV types using mass spectrometry. Multilevel logistic regression was used to estimate the expected number of multiple infections with specific HPV types, adjusted for age, type of sample, and accounting for correlations between HPV types due to unobserved risk factors using sample-level random effects. Bonferroni correction was used to allow for multiple comparisons (120). Observed-to-expected ratio for any multiple infections was slightly above unity in both sexes, but, for most 2-type combinations, there was no evidence of significant departure from expected numbers. HPV6/18 was found more often and HPV51/68 and 6/68 less often than expected. However, HPV68 tended to be generally underrepresented in co-infections, suggesting a sub-optimal performance of our testing method for this HPV type. We found no evidence for positive or negative clustering between HPV types included in the current prophylactic vaccines and other untargeted oncogenic types, in either sex.
Ebrahimi, Hossein; Hasankhani, Hadi; Namdar, Hossein; Fooladi, Marjaneh
2017-01-01
Background Today family members are providing care and support to each other during illness. In particular, in chronic illness, such as multiple sclerosis, the families are more involved in caring for and supporting their patients, so they use several strategies to cope with this situation. The purpose of this study was to explore the coping strategies in family caregivers of persons with multiple sclerosis in Iran. Methods This is a qualitative study that was conducted through 18 family caregivers of persons with multiple sclerosis. A purposeful sampling method was used. Data were collected through semistructured and in-depth interviews conducted in Multiple Sclerosis Society and hospitals of Tabriz in Iran. The collected data was analyzed according to qualitative content analysis. Results Five main categories were elicited from interviews: “using spirituality,” “living with hope,” “experiencing persistence and stability,” “seeking support,” and “seeking alternative treatments.” Conclusion. The study findings can help to inform the support given to families to help them cope with the effects of caring for someone with multiple sclerosis. Health system managers and professionals by using these results are able to support patients and their families appropriately in order to improve their quality of life and alleviate the complications of disease. PMID:29082042
Analysis of multiple enteric viral targets as sewage markers in coral reefs
Lipp, Erin K.; Futch, J. Carrie; Griffin, Dale W.
2007-01-01
Water and coral mucus samples were collected from throughout the Florida Keys National Marine Sanctuary and the Dry Tortugas for three years and were analyzed for human enteric viruses (enteroviruses, noroviruses, hepatitis A virus and adenoviruses) as conservative markers of human sewage using molecular methods. Of the 100 coral and water samples collected, 40 contained genetic material from one or more human enteric viruses. DNA-based adenoviruses were detected widely, in 37.8% of samples and at 91% of stations, including ‘pristine’ reefs in the Dry Tortugas; however, the detection rate was ⩽12% for the RNA-based enteroviruses and noroviruses (hepatitis A virus was never detected). The disparity between the prevalence of RNA- and DNA-based viruses suggests the need for additional work to determine the utility of adenovirus as marker of human sewage.
Clark, S.J.; Jackson, J.R.; Lochmann, S.E.
2007-01-01
We compared shoreline seines with fyke nets in terms of their ability to sample fish species in the littoral zone of 22 floodplain lakes of the White River, Arkansas. Lakes ranged in size from less than 0.5 to 51.0 ha. Most contained large amounts of coarse woody debris within the littoral zone, thus making seining in shallow areas difficult. We sampled large lakes (>2 ha) using three fyke nets; small lakes (<2 ha) were sampled using two fyke nets. Fyke nets were set for 24 h. Large lakes were sampled with an average of 11 seine hauls/ lake and small lakes were sampled with an average of 3 seine hauls/lake, but exact shoreline seining effort varied among lakes depending on the amount of open shoreline. Fyke nets collected more fish and produced greater species richness and diversity measures than did seining. Species evenness was similar for the two gear types. Two species were unique to seine samples, whereas 13 species and 3 families were unique to fyke-net samples. Although fyke nets collected more fish and more species than did shoreline seines, neither gear collected all the species present in the littoral zone of floodplain lakes. These results confirm the need for a multiple-gear approach to fully characterize the littoral fish assemblages in floodplain lakes. ?? Copyright by the American Fisheries Society 2007.
Lopez-Villanueva, Maria Eugenia; Conde-Ferráez, Laura; Ayora-Talavera, Guadalupe; Cerón-Espinosa, Jose D; González-Losa, Maria del Refugio
2011-01-01
Multifocal epithelial hyperplasia (MEH) is a disease of the oral mucosa. Human papillomaviruses 13 and 32 have been detected in these lesions. We describe the epidemiology and clinical characteristics of patients with MEH in a rural community in the Mayan area of Mexico with 53 cases and 54 controls. Clinical and epidemiological data were collected through a direct interview. Oral cell samples were collected with a cytobrush. Subjects collected their own saliva sample in a sterile bottle. All samples were tested for HPV 13 and 32 by polymerase chain reaction using specific primers. Of the 53 patients and 54 healthy subjects, 56% were < 12 years old, 25% were males and 75% females. Evolution of the lesions was between two months and 17 years. The lesions affected lips, jugal mucosa, and tongue, 96% had multiple lesions. From 53 patients, fifty samples of oral cells and 31 samples of saliva were analyzed. HPV 13 was detected in 100% oral cell and 100% saliva samples studied. 16 healthy subjects were HVP 13 positive. A highly significant association of HPV 13 infection and MEH was found, as determined by chi square test (p = 0.00) Household transmission of HPV 13 may happen through saliva and the shared use of contaminated objects.
The influence of serial fecal sampling on the diagnosis of giardiasis in humans, dogs, and cats.
Uchôa, Flávia Fernandes de Mendonça; Sudré, Adriana Pittella; Macieira, Daniel de Barros; Almosny, Nádia Regina Pereira
2017-08-24
Giardia infection is a common clinical problem in humans and pets. The diagnosis of giardiasis is challenging as hosts intermittently excrete protozoan cysts in their feces. In the present study, we comparatively evaluated two methods of serial fecal sampling in humans, dogs, and cats from Rio de Janeiro, Brazil. The Faust et al. technique was used to examine fecal specimens collected in triplicate from 133 patients (52 humans, 60 dogs, and 21 cats). Specimens from 74 patients were received from the group assigned to carry out sampling on consecutive days - 34 humans, 35 dogs, and 5 cats, and specimens from 59 patients were received from the group assigned to carry out sampling on non-consecutive, separate days - 18 human beings, 25 dogs, and 16 cats. G. duodenalis cysts were found in stools of 30 individuals. Multiple stool sampling resulted in an increase in the number of samples that were positive for Giardia in both groups. The authors therefore conclude that multiple stool sampling increases the sensitivity of the Faust et al . technique to detect G. duodenalis cysts in samples from humans, cats and dogs.
Surface sampling for endotoxin assessment using electrostatic wiping cloths.
Thorne, Peter S; Metwali, Nervana; Avol, Ed; McConnell, Rob S
2005-07-01
Much of the cost of exposure assessment for studies of residential cohorts is in scheduling and travel time for field staff. One way to reduce costs is to simplify methods such that subjects can sample their own residence. Analysis of settled dust is being widely used for assessment of exposures to allergens, lead and pesticides and can also be used for endotoxins. While vacuum sampling is the most common surface sampling method, wipe sampling has the advantage that it can be readily performed by the resident when convenient and samples can then be mailed to researchers. Thus, we evaluated the feasibility of wipe sampling for endotoxin environmental assessment using electrostatic wipes with or without the use of disposable examination gloves. Multiple lots of six types of commercial wipes and eight types of gloves were extracted and analyzed for endotoxin content using the kinetic chromogenic Limulus amebocyte lysate assay. Wipes were compared across brands, between lots, within lots, between pairs depending on proximity to cardboard packaging, and in wipe tests with or without gloves. Collected dust samples of known concentration were also tested in spiking assays for endotoxin recovery. The most striking finding was the high variability of endotoxin contamination of both wipes and gloves across brands and between various lots. The content of endotoxin in unused gloves ranged from <1.5 to 5810 endotoxin units (EU). The range for unused wipes was 3.6-87.8 EU. Surfaces of equal loading and area were sampled using three types of cloths that had low initial endotoxin contamination. The cloths were very good at collecting dust and endotoxin could be assayed from aqueous extracts of the wipes. Samples collected using cloths with bare washed hands yielded higher endotoxin loading per mass of collected dust versus samples collected wearing endotoxin-free gloves. This demonstrated additional endotoxin loading from the subject's hand. This study shows that wipe sampling while wearing medical gloves can be an effective method for collecting and assessing endotoxin on surfaces, so long as each lot of wipes and gloves have been tested and determined to be low in endotoxin.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fong, Erika J.; Huang, Chao; Hamilton, Julie
Here, a major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection,more » system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.« less
Development of a Novel Method for Temporal Analysis of Airborne Microbial Communities
NASA Astrophysics Data System (ADS)
Spring, A.; Domingue, K. D.; Mooney, M. M.; Kerber, T. V.; Lemmer, K. M.; Docherty, K. M.
2017-12-01
Microorganisms are ubiquitous in the atmosphere, which serves as an important vector for microbial dispersal to all terrestrial habitats. Very little is known about the mechanisms that control microbial dispersal, because sampling of airborne microbial communities beyond 2 m above the ground is limited. The goal of this study was to construct and test an airborne microbial sampling system to collect sufficient DNA for conducting next generation sequencing and microbial community analyses. The system we designed employs helium-filled helikites as a mechanism for launching samplers to various altitudes. The samplers use a passive collection dish system, weigh under 6 lbs and are operated by remote control from the ground. We conducted several troubleshooting experiments to test sampler functionality. We extracted DNA from sterile collection dish surfaces and examined communities using amplicons of the V4 region of 16S rRNA in bacteria using Illumina Mi-Seq. The results of these experiments demonstrate that the samplers we designed 1) remain decontaminated when closed and collect sufficient microbial biomass for DNA-based analyses when open for 6 hours; 2) are optimally decontaminated with 15 minutes of UV exposure; 3) require 8 collection dish surfaces to collect sufficient biomass. We also determined that DNA extraction conducted within 24 hours of collection has less of an impact on community composition than extraction after frozen storage. Using this sampling system, we collected samples from multiple altitudes in December 2016 and May 2017 at 3 sites in Kalamazoo and Pellston, Michigan. In Kalamazoo, areas sampled were primarily developed or agricultural, while in Pellston they were primarily forested. We observed significant differences between airborne bacterial communities collected at each location and time point. Additionally, bacterial communities did not differ with altitude, suggesting that terrestrial land use has an important influence on the upward distribution of bacteria. Proteobacteria were predominant in air samples from Kalamazoo, while Firmicutes were more prevalent in Pellston. Our results demonstrate that the sampling platform we designed is a useful tool for exploring ecological questions related to distribution of airborne microbial communities across a vertical transect.
Water flow in high-speed handpieces.
Cavalcanti, Bruno Neves; Serairdarian, Paulo Isaías; Rode, Sigmar Mello
2005-05-01
This study measured the water flow commonly used in high-speed handpieces to evaluate the water flow's influence on temperature generation. Different flow speeds were evaluated between turbines that had different numbers of cooling apertures. Two water samples were collected from each high-speed handpiece at private practices and at the School of Dentistry at São José dos Campos. The first sample was collected at the customary flow and the second was collected with the terminal opened for maximum flow. The two samples were collected into weighed glass receptacles after 15 seconds of turbine operation. The glass receptacles were reweighed and the difference between weights was recorded to calculate the water flow in mL/min and for further statistical analysis. The average water flow for 137 samples was 29.48 mL/min. The flow speeds obtained were 42.38 mL/min for turbines with one coolant aperture; 34.31 mL/min for turbines with two coolant apertures; and 30.44 mL/min for turbines with three coolant apertures. There were statistical differences between turbines with one and three coolant apertures (Tukey-Kramer multiple comparisons test with P < .05). Turbine handpieces with one cooling aperture distributed more water for the burs than high-speed handpieces with more than one aperture.
Urushadze, Teo
2018-01-01
Water quality contamination by heavy metal pollution has severe effects on public health. In the Mashavera River Basin, an important agricultural area for the national food system in Georgia (e.g., vegetable, dairy and wine production), water contamination has multiple influences on the regional and country-wide health. With new industrial activities in the region, sediment extraction, and discharge of untreated wastewater into the river, its tributaries and irrigation canals, a comprehensive study of water quality was greatly needed. This study examined sediment and water samples from 17 sampling sites in the Mashavera River Basin during the high and low precipitation seasons. The results were characterized utilizing the Geo-accumulation Index (Igeo), Enrichment Factor (EF), Pollution Load index (PLI), Contamination Factor (CF) and Metal Index (MI). According to the CFs, Cu > Cd > Zn > Pb > Fe > Mn > Ni > Cr > Hg is the descending order for the content of all observed heavy metals in sediments collected in both seasons. Fe and As were additionally examined in water samples. Overall, As, Cd and Pb, all highly toxic elements, were found in high concentrations in downstream sample sites. According to these results, comprehensive monitoring with narrow intervals between sampling dates, more sample sites along all waterways, and proximate observation of multiple trace metal elements are highly recommended. Moreover, as the part of the water quality governance system, an immediate and sustainable collective action by all stakeholders to control the pollution level is highly recommended, as this issue is linked to the security of the national food system and poses a local public health risk. PMID:29597320
Alam, Muhammad Masroor; Shaukat, Shahzad; Sharif, Salmaan; Angez, Mehar; Khurshid, Adnan; Malik, Farzana; Rehman, Lubna; Zaidi, Syed Sohail Zahoor
2014-11-01
The environmental surveillance has proven to be a useful tool to identify poliovirus circulation in different countries and was started in Pakistan during July 2009 to support the acute flaccid paralysis (AFP) surveillance system. Sewage samples were collected from 27 environmental sampling (ENV) sites and processed for poliovirus isolation through 2-phase separation method. Poliovirus isolates were identified as Sabin-like or wild type through real-time polymerase chain reaction (PCR). Wild-type strains were subjected to VP1 gene sequencing and phylogenetic analysis performed using MEGA 5.0. During 2011-2013, a total of 668 samples were collected from 4 provinces that resulted in 40% of samples positive for wild poliovirus type-1 (WPV-1). None of the samples were positive for WPV-3. The areas with high frequency of WPV-1 detection were Karachi-Gadap (69%), Peshawar (82%), and Rawalpindi (65%), whereas the samples from Quetta and Sukkur remained negative for WPV during 2013. Phylogenetic analysis revealed 3 major clusters with multiple poliovirus lineages circulating across different country areas as well as in bordering areas of Afghanistan. Environmental surveillance in Pakistan has been proven to be a powerful tool to detect WPV circulation in the absence of poliomyelitis cases in many communities. Our findings emphasize the need to continue and expand such surveillance activities to other high-risk areas in the country. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Bayesian function-on-function regression for multilevel functional data.
Meyer, Mark J; Coull, Brent A; Versace, Francesco; Cinciripini, Paul; Morris, Jeffrey S
2015-09-01
Medical and public health research increasingly involves the collection of complex and high dimensional data. In particular, functional data-where the unit of observation is a curve or set of curves that are finely sampled over a grid-is frequently obtained. Moreover, researchers often sample multiple curves per person resulting in repeated functional measures. A common question is how to analyze the relationship between two functional variables. We propose a general function-on-function regression model for repeatedly sampled functional data on a fine grid, presenting a simple model as well as a more extensive mixed model framework, and introducing various functional Bayesian inferential procedures that account for multiple testing. We examine these models via simulation and a data analysis with data from a study that used event-related potentials to examine how the brain processes various types of images. © 2015, The International Biometric Society.
Abrahamsson, Sara; McQuilken, Molly; Mehta, Shalin B.; Verma, Amitabh; Larsch, Johannes; Ilic, Rob; Heintzmann, Rainer; Bargmann, Cornelia I.; Gladfelter, Amy S.; Oldenbourg, Rudolf
2015-01-01
We have developed an imaging system for 3D time-lapse polarization microscopy of living biological samples. Polarization imaging reveals the position, alignment and orientation of submicroscopic features in label-free as well as fluorescently labeled specimens. Optical anisotropies are calculated from a series of images where the sample is illuminated by light of different polarization states. Due to the number of images necessary to collect both multiple polarization states and multiple focal planes, 3D polarization imaging is most often prohibitively slow. Our MF-PolScope system employs multifocus optics to form an instantaneous 3D image of up to 25 simultaneous focal-planes. We describe this optical system and show examples of 3D multi-focus polarization imaging of biological samples, including a protein assembly study in budding yeast cells. PMID:25837112
Evaluation of sewage source and fate on southeast Florida coastal reefs
Carrie, Futch J.; Griffin, Dale W.; Banks, K.; Lipp, E.K.
2011-01-01
Water, sponge and coral samples were collected from stations impacted by a variety of pollution sources and screened for human enteric viruses as conservative markers for human sewage. While human enteroviruses and adenoviruses were not detected, noroviruses (NoV; human genogroups I and II) were detected in 31% of samples (especially in sponge tissue). Stations near inlets were the only ones to show multiple sample types positive for NoV. Fecal indicator bacteria and enteric viruses were further evaluated at multiple inlet stations on an outgoing tide. Greatest indicator concentrations and highest prevalence of viruses were found at the mouth of the inlet and offshore in the inlet plume. Results suggest that inlets moving large volumes of water into the coastal zone with tides may be an important source of fecal contaminants. Efforts to reduce run-off or unintended release of water into the Intracoastal Waterway may lower contaminants entering sensitive coastal areas. ?? 2011 Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Fukami, Christine S.; Sullivan, Amy P.; Ryan Fulgham, S.; Murschell, Trey; Borch, Thomas; Smith, James N.; Farmer, Delphine K.
2016-07-01
Particle-into-Liquid Samplers (PILS) have become a standard aerosol collection technique, and are widely used in both ground and aircraft measurements in conjunction with off-line ion chromatography (IC) measurements. Accurate and precise background samples are essential to account for gas-phase components not efficiently removed and any interference in the instrument lines, collection vials or off-line analysis procedures. For aircraft sampling with PILS, backgrounds are typically taken with in-line filters to remove particles prior to sample collection once or twice per flight with more numerous backgrounds taken on the ground. Here, we use data collected during the Front Range Air Pollution and Photochemistry Éxperiment (FRAPPÉ) to demonstrate that not only are multiple background filter samples are essential to attain a representative background, but that the chemical background signals do not follow the Gaussian statistics typically assumed. Instead, the background signals for all chemical components analyzed from 137 background samples (taken from ∼78 total sampling hours over 18 flights) follow a log-normal distribution, meaning that the typical approaches of averaging background samples and/or assuming a Gaussian distribution cause an over-estimation of background samples - and thus an underestimation of sample concentrations. Our approach of deriving backgrounds from the peak of the log-normal distribution results in detection limits of 0.25, 0.32, 3.9, 0.17, 0.75 and 0.57 μg m-3 for sub-micron aerosol nitrate (NO3-), nitrite (NO2-), ammonium (NH4+), sulfate (SO42-), potassium (K+) and calcium (Ca2+), respectively. The difference in backgrounds calculated from assuming a Gaussian distribution versus a log-normal distribution were most extreme for NH4+, resulting in a background that was 1.58× that determined from fitting a log-normal distribution.
Digital Curation of Marine Physical Samples at Ocean Networks Canada
NASA Astrophysics Data System (ADS)
Jenkyns, R.; Tomlin, M. C.; Timmerman, R.
2015-12-01
Ocean Networks Canada (ONC) has collected hundreds of geological, biological and fluid samples from the water column and seafloor during its maintenance expeditions. These samples have been collected by Remotely Operated Vehicles (ROVs), divers, networked and autonomously deployed instruments, and rosettes. Subsequent measurements are used for scientific experiments, calibration of in-situ and remote sensors, monitoring of Marine Protected Areas, and environment characterization. Tracking the life cycles of these samples from collection to dissemination of results with all the pertinent documents (e.g., protocols, imagery, reports), metadata (e.g., location, identifiers, purpose, method) and data (e.g., measurements, taxonomic classification) is a challenge. The initial collection of samples is normally documented in SeaScribe (an ROV dive logging tool within ONC's Oceans 2.0 software) for which ONC has defined semantics and syntax. Next, samples are often sent to individual scientists and institutions (e.g., Royal BC Museum) for processing and storage, making acquisition of results and life cycle metadata difficult. Finally, this information needs to be retrieved and collated such that multiple user scenarios can be addressed. ONC aims to improve and extend its digital infrastructure for physical samples to support this complex array of samples, workflows and applications. However, in order to promote effective data discovery and exchange, interoperability and community standards must be an integral part of the design. Thus, integrating recommendations and outcomes of initiatives like the EarthCube iSamples working groups are essential. Use cases, existing tools, schemas and identifiers are reviewed, while remaining gaps and challenges are identified. The current status, selected approaches and possible future directions to enhance ONC's digital infrastructure for each sample type are presented.
Daigle, Courtney L; Siegford, Janice M
2014-03-01
Continuous observation is the most accurate way to determine animals' actual time budget and can provide a 'gold standard' representation of resource use, behavior frequency, and duration. Continuous observation is useful for capturing behaviors that are of short duration or occur infrequently. However, collecting continuous data is labor intensive and time consuming, making multiple individual or long-term data collection difficult. Six non-cage laying hens were video recorded for 15 h and behavioral data collected every 2 s were compared with data collected using scan sampling intervals of 5, 10, 15, 30, and 60 min and subsamples of 2 second observations performed for 10 min every 30 min, 15 min every 1 h, 30 min every 1.5 h, and 15 min every 2 h. Three statistical approaches were used to provide a comprehensive analysis to examine the quality of the data obtained via different sampling methods. General linear mixed models identified how the time budget from the sampling techniques differed from continuous observation. Correlation analysis identified how strongly results from the sampling techniques were associated with those from continuous observation. Regression analysis identified how well the results from the sampling techniques were associated with those from continuous observation, changes in magnitude, and whether a sampling technique had bias. Static behaviors were well represented with scan and time sampling techniques, while dynamic behaviors were best represented with time sampling techniques. Methods for identifying an appropriate sampling strategy based upon the type of behavior of interest are outlined and results for non-caged laying hens are presented. Copyright © 2013 Elsevier B.V. All rights reserved.
2012-2013 Delaware Valley Household Travel Survey | Transportation Secure
Data Center | NREL 12-2013 Delaware Valley Household Travel Survey 2012-2013 Delaware Valley Household Travel Survey The 2012-2013 Delaware Valley Household Travel Survey collected data for multiple ) sponsored the survey in collaboration with AbtSRBI. Methodology A sampling strategy was designed to recruit
Stream macroinvertebrate collection methods described in the Rapid Bioassessment Protocols (RBPs) have been used widely throughout the U.S. The first edition of the RBP manual in 1989 described a single habitat approach that focused on riffles and runs, where macroinvertebrate d...
ACER Chemistry Test Item Collection. ACER Chemtic Year 12.
ERIC Educational Resources Information Center
Australian Council for Educational Research, Hawthorn.
The chemistry test item banks contains 225 multiple-choice questions suitable for diagnostic and achievement testing; a three-page teacher's guide; answer key with item facilities; an answer sheet; and a 45-item sample achievement test. Although written for the new grade 12 chemistry course in Victoria, Australia, the items are widely applicable.…
Joint Trajectories of Behavioral, Affective, and Cognitive Engagement in Elementary School
ERIC Educational Resources Information Center
Archambault, Isabelle; Dupéré, Véronique
2017-01-01
The aim of the present study was to model student trajectories of behavioral, affective, and cognitive engagement from Grade 3 to Grade 6. The authors also examined whether teachers perceptions could predict student trajectory membership. The authors collected data from a sample of 831 students and 152 teachers. Using multiple-process growth…
EFFECT OF CONVENTIONAL AND ADVANCED COAL CONVERSION BY-PRODUCTS ON THE PULMONARY SYSTEM
To evaluate the environmental impact of different energy technologies, fly ash samples collected from a coal-fired and from an oil-fired electric power plant were used in aerosol inhalation exposures of mice. The effects of multiple 3-h exposures to the fly ash particles at 2 and...
This research characterizes associations between multiple pollutants in the near-road environment attributed to a roadway line source. It also examines the use of a tracer gas as a surrogate of mobile source pollutants. Air samples were collected in summa canisters along a 300 m ...
Jewish Women's Psychological Well-Being: The Role of Attachment, Separation, and Jewish Identity
ERIC Educational Resources Information Center
Goldberg, Julie L.; O'Brien, Karen M.
2005-01-01
The purpose of this study was to examine the contributions of attachment, separation, and Jewish identity to psychological well-being in a sample of 115 late adolescent Jewish women. Results from multiple regression analyses demonstrated that attachment to parents, separation from parents, and Jewish identity collectively accounted for variance in…
Predictors of Career Adaptability Skill among Higher Education Students in Nigeria
ERIC Educational Resources Information Center
Ebenehi, Amos Shaibu; Rashid, Abdullah Mat; Bakar, Ab Rahim
2016-01-01
This paper examined predictors of career adaptability skill among higher education students in Nigeria. A sample of 603 higher education students randomly selected from six colleges of education in Nigeria participated in this study. A set of self-reported questionnaire was used for data collection, and multiple linear regression analysis was used…
Exhaled Breath Condensate Collection in the Mechanically Ventilated Patient
Carter, Stewart R; Davis, Christopher S; Kovacs, Elizabeth J
2012-01-01
Collection of exhaled breath condensate (EBC) is a non-invasive means of sampling the airway-lining fluid of the lungs. EBC contains numerous measurable mediators, whose analysis could change the management of patients with certain pulmonary diseases. While initially popularized in investigations involving spontaneously breathing patients, an increasing number of studies have been performed using EBC in association with mechanical ventilation. Collection of EBC in mechanically ventilated patients follows basic principles of condensation, but is influenced by multiple factors. Effective collection requires selection of a collection device, adequate minute ventilation, low cooling temperatures, and sampling times of greater than ten minutes. Condensate can be contaminated by saliva, which needs to be filtered. Dilution of samples occurs secondary to distilled water in vapors and humidification in the ventilator circuit. Dilution factors may need to be employed when investigating non-volatile biomarkers. Storage and analysis should occur promptly at −70° C to −80° C to prevent rapid degradation of samples. The purpose of this review is to examine and describe methodologies and problems of EBC collection in mechanically ventilated patients. A straightforward and safe framework has been established to investigate disease processes in this population, yet technical aspects of EBC collection still exist that prevent clinical practicality of this technology. These include a lack of standardization of procedure and analysis of biomarkers, and of normal reference ranges for mediators in healthy individuals. Once these procedural aspects have been addressed, EBC could serve as a non-invasive alternative to invasive evaluation of lungs in mechanically ventilated patients. PMID:22398157
Use of FTA sampling cards for molecular detection of avian influenza virus in wild birds.
Keeler, Shamus P; Ferro, Pamela J; Brown, Justin D; Fang, Xingwang; El-Attrache, John; Poulson, Rebecca; Jackwood, Mark W; Stallknecht, David E
2012-03-01
Current avian influenza (AI) virus surveillance programs involving wild birds rely on sample collection methods that require refrigeration or low temperature freezing to maintain sample integrity for virus isolation and/or reverse-transcriptase (RT) PCR. Maintaining the cold chain is critical for the success of these diagnostic assays but is not always possible under field conditions. The aim of this study was to test the utility of Finders Technology Associates (FTA) cards for reliable detection of AI virus from cloacal and oropharyngeal swabs of wild birds. The minimum detectable titer was determined, and the effect of room temperature storage was evaluated experimentally using multiple egg-propagated stock viruses (n = 6). Using real time RT-PCR, we compared results from paired cloacal swab and samples collected on FTA cards from both experimentally infected mallards (Anasplatyrhynchos) and hunter-harvested waterfowl sampled along the Texas Gulf Coast. Based on the laboratory trials, the average minimal detectable viral titer was determined to be 1 x 10(4.7) median embryo infectious dose (EID50)/ml (range: 1 x 10(4.3) to 1 x 10(5.4) EID50/ml), and viral RNA was consistently detectable on the FTA cards for a minimum of 20 days and up to 30 days for most subtypes at room temperature (23 C) storage. Real-time RT-PCR of samples collected using the FTA cards showed fair to good agreement in live birds when compared with both real-time RT-PCR and virus isolation of swabs. AI virus detection rates in samples from several wild bird species were higher when samples were collected using the FTA cards compared with cloacal swabs. These results suggest that FTA cards can be used as an alternative sample collection method when traditional surveillance methods are not possible, especially in avian populations that have historically received limited testing or situations in which field conditions limit the ability to properly store or ship swab samples.
Biomolecular signatures of diabetic wound healing by structural mass spectrometry
Hines, Kelly M.; Ashfaq, Samir; Davidson, Jeffrey M.; Opalenik, Susan R.; Wikswo, John P.; McLean, John A.
2013-01-01
Wound fluid is a complex biological sample containing byproducts associated with the wound repair process. Contemporary techniques, such as immunoblotting and enzyme immunoassays, require extensive sample manipulation and do not permit the simultaneous analysis of multiple classes of biomolecular species. Structural mass spectrometry, implemented as ion mobility-mass spectrometry (IM-MS), comprises two sequential, gas-phase dispersion techniques well suited for the study of complex biological samples due to its ability to separate and simultaneously analyze multiple classes of biomolecules. As a model of diabetic wound healing, polyvinyl alcohol (PVA) sponges were inserted subcutaneously into non-diabetic (control) and streptozotocin-induced diabetic rats to elicit a granulation tissue response and to collect acute wound fluid. Sponges were harvested at days 2 or 5 to capture different stages of the early wound healing process. Utilizing IM-MS, statistical analysis, and targeted ultra-performance liquid chromatography (UPLC) analysis, biomolecular signatures of diabetic wound healing have been identified. The protein S100-A8 was highly enriched in the wound fluids collected from day 2 diabetic rats. Lysophosphatidylcholine (20:4) and cholic acid also contributed significantly to the differences between diabetic and control groups. This report provides a generalized workflow for wound fluid analysis demonstrated with a diabetic rat model. PMID:23452326
Ortiz, Genaro Gabriel; Macías-Islas, Miguel Ángel; Pacheco-Moisés, Fermín P.; Cruz-Ramos, José A.; Sustersik, Silvia; Barba, Elías Alejandro; Aguayo, Adriana
2009-01-01
Objective: To determine the oxidative stress markers in serum from patients with relapsing-remitting multiple sclerosis. Methods: Blood samples from healthy controls and 22 patients 15 women (7 aged from 20 to 30 and 8 were > 40 years old) and 7 men (5 aged from 20 to 30 and 2 were > 40 years old) fulfilling the McDonald Criteria and classified as having Relapsing-Remitting Multiple Sclerosis accordingly with Lublin were collected for oxidative stress markers quantification. Results: Nitric oxide metabolites (nitrates/nitrites), lipid peroxidation products (malondialdehyde plus 4-hidroxialkenals), and glutathione peroxidase activity were significantly increased in serum of subjects with relapsing-remitting multiple sclerosis in comparison with that of healthy controls. These data support the hypothesis that multiple sclerosis is a component closely linked to oxidative stress. PMID:19242067
Defibaugh-Chavez, Stephanie; Douris, Aphrodite; Vetter, Danah; Atkinson, Richard; Kissler, Bonnie; Khroustalev, Allison; Robertson, Kis; Sharma, Yudhbir; Becker, Karen; Dessai, Uday; Antoine, Nisha; Allen, Latasha; Holt, Kristin; Gieraltowski, Laura; Wise, Matthew; Schwensohn, Colin
2018-01-01
Abstract On June 28, 2013, the Food Safety and Inspection Service (FSIS) was notified by the Centers for Disease Control and Prevention (CDC) of an investigation of a multistate cluster of illnesses of Salmonella enterica serovar Heidelberg. Since case-patients in the cluster reported consumption of a variety of chicken products, FSIS used a simple likelihood-based approach using traceback information to focus on intensified sampling efforts. This article describes the multiphased product sampling approach taken by FSIS when epidemiologic evidence implicated chicken products from multiple establishments operating under one corporation. The objectives of sampling were to (1) assess process control of chicken slaughter and further processing and (2) determine whether outbreak strains were present in products from these implicated establishments. As part of the sample collection process, data collected by FSIS personnel to characterize product included category (whole chicken and type of chicken parts), brand, organic or conventional product, injection with salt solutions or flavorings, and whether product was skinless or skin-on. From the period September 9, 2013, through October 31, 2014, 3164 samples were taken as part of this effort. Salmonella percent positive declined from 19.7% to 5.3% during this timeframe as a result of regulatory and company efforts. The results of intensified sampling for this outbreak investigation informed an FSIS regulatory response and corrective actions taken by the implicated establishments. The company noted that a multihurdle approach to reduce Salmonella in products was taken, including on-farm efforts such as environmental testing, depopulation of affected flocks, disinfection of affected houses, vaccination, and use of various interventions within the establishments over the course of several months. PMID:29638165
Synchronous in-field application of life-detection techniques in planetary analog missions
NASA Astrophysics Data System (ADS)
Amador, Elena S.; Cable, Morgan L.; Chaudry, Nosheen; Cullen, Thomas; Gentry, Diana; Jacobsen, Malene B.; Murukesan, Gayathri; Schwieterman, Edward W.; Stevens, Adam H.; Stockton, Amanda; Yin, Chang; Cullen, David C.; Geppert, Wolf
2015-02-01
Field expeditions that simulate the operations of robotic planetary exploration missions at analog sites on Earth can help establish best practices and are therefore a positive contribution to the planetary exploration community. There are many sites in Iceland that possess heritage as planetary exploration analog locations and whose environmental extremes make them suitable for simulating scientific sampling and robotic operations. We conducted a planetary exploration analog mission at two recent lava fields in Iceland, Fimmvörðuháls (2010) and Eldfell (1973), using a specially developed field laboratory. We tested the utility of in-field site sampling down selection and tiered analysis operational capabilities with three life detection and characterization techniques: fluorescence microscopy (FM), adenine-triphosphate (ATP) bioluminescence assay, and quantitative polymerase chain reaction (qPCR) assay. The study made use of multiple cycles of sample collection at multiple distance scales and field laboratory analysis using the synchronous life-detection techniques to heuristically develop the continuing sampling and analysis strategy during the expedition. Here we report the operational lessons learned and provide brief summaries of scientific data. The full scientific data report will follow separately. We found that rapid in-field analysis to determine subsequent sampling decisions is operationally feasible, and that the chosen life detection and characterization techniques are suitable for a terrestrial life-detection field mission. In-field analysis enables the rapid obtainment of scientific data and thus facilitates the collection of the most scientifically relevant samples within a single field expedition, without the need for sample relocation to external laboratories. The operational lessons learned in this study could be applied to future terrestrial field expeditions employing other analytical techniques and to future robotic planetary exploration missions.
GHSI EMERGENCY RADIONUCLIDE BIOASSAY LABORATORY NETWORK - SUMMARY OF THE SECOND EXERCISE.
Li, Chunsheng; Bartizel, Christine; Battisti, Paolo; Böttger, Axel; Bouvier, Céline; Capote-Cuellar, Antonio; Carr, Zhanat; Hammond, Derek; Hartmann, Martina; Heikkinen, Tarja; Jones, Robert L; Kim, Eunjoo; Ko, Raymond; Koga, Roberto; Kukhta, Boris; Mitchell, Lorna; Morhard, Ryan; Paquet, Francois; Quayle, Debora; Rulik, Petr; Sadi, Baki; Sergei, Aleksanin; Sierra, Inmaculada; de Oliveira Sousa, Wanderson; Szab, Gyula
2017-05-01
The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency as a means of enhancing response capability, health outcomes and community resilience. GHSI partners conducted an exercise in collaboration with the WHO Radiation Emergency Medical Preparedness and Assistance Network and the IAEA Response and Assistance Network, to test the participating laboratories (18) for their capabilities in in vitro assay of biological samples, using a urine sample spiked with multiple high-risk radionuclides (90Sr, 106Ru, 137Cs, and 239Pu). Laboratories were required to submit their reports within 72 h following receipt of the sample, using a pre-formatted template, on the procedures, methods and techniques used to identify and quantify the radionuclides in the sample, as well as the bioassay results with a 95% confidence interval. All of the participating laboratories identified and measured all or some of the radionuclides in the sample. However, gaps were identified in both the procedures used to assay multiple radionuclides in one sample, as well as in the methods or techniques used to assay specific radionuclides in urine. Two-third of the participating laboratories had difficulties in determining all the radionuclides in the sample. Results from this exercise indicate that challenges remain with respect to ensuring that results are delivered in a timely, consistent and reliable manner to support medical interventions. Laboratories within the networks are encouraged to work together to develop and maintain collective capabilities and capacity for emergency bioassay, which is an important component of radiation emergency response. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
GHSI Emergency Radionuclide Bioassay Laboratory Network - Summary of the Second Exercise
Li, Chunsheng; Bartizel, Christine; Battisti, Paolo; Böttger, Axel; Bouvier, Céline; Capote-Cuellar, Antonio; Carr, Zhanat; Hammond, Derek; Hartmann, Martina; Heikkinen, Tarja; Jones, Robert L.; Kim, Eunjoo; Ko, Raymond; Koga, Roberto; Kukhta, Boris; Mitchell, Lorna; Morhard, Ryan; Paquet, Francois; Quayle, Debora; Rulik, Petr; Sadi, Baki; Sergei, Aleksanin; Sierra, Inmaculada; de Oliveira Sousa, Wanderson; Szabó, Gyula
2017-01-01
The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency as a means of enhancing response capability, health outcomes and community resilience. GHSI partners conducted an exercise in collaboration with the WHO REMPAN (Radiation Emergency Medical Preparedness and Assistance Network) and the IAEA RANET (Response and Assistance Network), to test the participating laboratories (18) for their capabilities in in vitro assay of biological samples, using a urine sample spiked with multiple high-risk radionuclides (90Sr, 106Ru, 137Cs, and 239Pu). Laboratories were required to submit their reports within 72 hours following receipt of the sample, using a pre-formatted template, on the procedures, methods and techniques used to identify and quantify the radionuclides in the sample, as well as the bioassay results with a 95% confidence interval. All of the participating laboratories identified and measured all or some of the radionuclides in the sample. However, gaps were identified in both the procedures used to assay multiple radionuclides in one sample, as well as in the methods or techniques used to assay specific radionuclides in urine. Two third of the participating laboratories had difficulties in determining all the radionuclides in the sample. Results from this exercise indicate that challenges remain with respect to ensuring that results are delivered in a timely, consistent and reliable manner to support medical interventions. Laboratories within the networks are encouraged to work together to develop and maintain collective capabilities and capacity for emergency bioassay, which is an important component of radiation emergency response. PMID:27574317
Iachan, Ronaldo; H. Johnson, Christopher; L. Harding, Richard; Kyle, Tonja; Saavedra, Pedro; L. Frazier, Emma; Beer, Linda; L. Mattson, Christine; Skarbinski, Jacek
2016-01-01
Background: Health surveys of the general US population are inadequate for monitoring human immunodeficiency virus (HIV) infection because the relatively low prevalence of the disease (<0.5%) leads to small subpopulation sample sizes. Objective: To collect a nationally and locally representative probability sample of HIV-infected adults receiving medical care to monitor clinical and behavioral outcomes, supplementing the data in the National HIV Surveillance System. This paper describes the sample design and weighting methods for the Medical Monitoring Project (MMP) and provides estimates of the size and characteristics of this population. Methods: To develop a method for obtaining valid, representative estimates of the in-care population, we implemented a cross-sectional, three-stage design that sampled 23 jurisdictions, then 691 facilities, then 9,344 HIV patients receiving medical care, using probability-proportional-to-size methods. The data weighting process followed standard methods, accounting for the probabilities of selection at each stage and adjusting for nonresponse and multiplicity. Nonresponse adjustments accounted for differing response at both facility and patient levels. Multiplicity adjustments accounted for visits to more than one HIV care facility. Results: MMP used a multistage stratified probability sampling design that was approximately self-weighting in each of the 23 project areas and nationally. The probability sample represents the estimated 421,186 HIV-infected adults receiving medical care during January through April 2009. Methods were efficient (i.e., induced small, unequal weighting effects and small standard errors for a range of weighted estimates). Conclusion: The information collected through MMP allows monitoring trends in clinical and behavioral outcomes and informs resource allocation for treatment and prevention activities. PMID:27651851
Olives, Casey; Valadez, Joseph J.; Brooker, Simon J.; Pagano, Marcello
2012-01-01
Background Originally a binary classifier, Lot Quality Assurance Sampling (LQAS) has proven to be a useful tool for classification of the prevalence of Schistosoma mansoni into multiple categories (≤10%, >10 and <50%, ≥50%), and semi-curtailed sampling has been shown to effectively reduce the number of observations needed to reach a decision. To date the statistical underpinnings for Multiple Category-LQAS (MC-LQAS) have not received full treatment. We explore the analytical properties of MC-LQAS, and validate its use for the classification of S. mansoni prevalence in multiple settings in East Africa. Methodology We outline MC-LQAS design principles and formulae for operating characteristic curves. In addition, we derive the average sample number for MC-LQAS when utilizing semi-curtailed sampling and introduce curtailed sampling in this setting. We also assess the performance of MC-LQAS designs with maximum sample sizes of n = 15 and n = 25 via a weighted kappa-statistic using S. mansoni data collected in 388 schools from four studies in East Africa. Principle Findings Overall performance of MC-LQAS classification was high (kappa-statistic of 0.87). In three of the studies, the kappa-statistic for a design with n = 15 was greater than 0.75. In the fourth study, where these designs performed poorly (kappa-statistic less than 0.50), the majority of observations fell in regions where potential error is known to be high. Employment of semi-curtailed and curtailed sampling further reduced the sample size by as many as 0.5 and 3.5 observations per school, respectively, without increasing classification error. Conclusion/Significance This work provides the needed analytics to understand the properties of MC-LQAS for assessing the prevalance of S. mansoni and shows that in most settings a sample size of 15 children provides a reliable classification of schools. PMID:22970333
Shackney, Stanley; Emlet, David R; Pollice, Agnese; Smith, Charles; Brown, Kathryn; Kociban, Deborah
2006-01-01
Laser scanning Cytometry (LSC) is a versatile technology that makes it possible to perform multiple measurements on individual cells and correlate them cell by cell with other cellular features. It would be highly desirable to be able to perform reproducible, quantitative, correlated cell-based immunofluorescence studies on individual cells from human solid tumors. However, such studies can be challenging because of the presence of large numbers of cell aggregates and other confounding factors. Techniques have been developed to deal with cell aggregates in data sets collected by LSC. Experience has also been gained in addressing other key technical and methodological issues that can affect the reproducibility of such cell-based immunofluorescence measurements. We describe practical aspects of cell sample collection, cell fixation and staining, protocols for performing multiparameter immunofluorescence measurements by LSC, use of controls and reference samples, and approaches to data analysis that we have found useful in improving the accuracy and reproducibility of LSC data obtained in human tumor samples. We provide examples of the potential advantages of LSC in examining quantitative aspects of cell-based analysis. Improvements in the quality of cell-based multiparameter immunofluorescence measurements make it possible to extract useful information from relatively small numbers of cells. This, in turn, permits the performance of multiple multicolor panels on each tumor sample. With links among the different panels that are provided by overlapping measurements, it is possible to develop increasingly more extensive profiles of intracellular expression of multiple proteins in clinical samples of human solid tumors. Examples of such linked panels of measurements are provided. Advances in methodology can improve cell-based multiparameter immunofluorescence measurements on cell suspensions from human solid tumors by LSC for use in prognostic and predictive clinical applications. Copyright (c) 2005 Wiley-Liss, Inc.
Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Morgan P.; Groh, Tyler A.; Parkin, Timothy B.
Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gasmore » flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.« less
Validation of spot-testing kits to determine iodine content in salt.
Pandav, C. S.; Arora, N. K.; Krishnan, A.; Sankar, R.; Pandav, S.; Karmarkar, M. G.
2000-01-01
Iodine deficiency disorders are a major public health problem, and salt iodization is the most widely practised intervention for their elimination. For the intervention to be successful and sustainable, it is vital to monitor the iodine content of salt regularly. Iodometric titration, the traditional method for measuring iodine content, has problems related to accessibility and cost. The newer spot-testing kits are inexpensive, require minimal training, and provide immediate results. Using data from surveys to assess the availability of iodized salt in two states in India, Madhya Pradesh and the National Capital Territory of Delhi, we tested the suitability of such a kit in field situations. Salt samples from Delhi were collected from 30 schools, chosen using the Expanded Programme on Immunization (EPI) cluster sampling technique. A single observer made the measurement for iodine content using the kit. Salt samples from Madhya Pradesh were from 30 rural and 30 urban clusters, identified by using census data and the EPI cluster sampling technique. In each cluster, salt samples were collected from 10 randomly selected households and all retailers. The 15 investigators performing the survey estimated the iodine content of salt samples in the field using the kit. All the samples were brought to the central laboratory in Delhi, where iodine content was estimated using iodometric titration as a reference method. The agreement between the kit and titration values decreased as the number of observers increased. Although sensitivity was not much affected by the increase in the number of observers (93.3% for a single observer and 93.9% for multiple observers), specificity decreased sharply (90.4% for a single observer and 40.4% for multiple observers). Due to the low specificity and resulting high numbers of false-positives for the kit when used by multiple observers ("real-life situations"), kits were likely to consistently overestimate the availability of iodized salt. This overestimation could result in complacency. Therefore, we conclude that until a valid alternative is available, the titration method should be used for monitoring the iodine content of salt at all levels, from producer to consumer, to ensure effectiveness of the programme. PMID:10994281
Lievers, Rik; Groot, Astrid T
2016-01-01
In the past decades, the sex pheromone composition in female moths has been analyzed by different methods, ranging from volatile collections to gland extractions, which all have some disadvantage: volatile collections can generally only be conducted on (small) groups of females to detect the minor pheromone compounds, whereas gland extractions are destructive. Direct-contact SPME overcomes some of these disadvantages, but is expensive, the SPME fiber coating can be damaged due to repeated usage, and samples need to be analyzed relatively quickly after sampling. In this study, we assessed the suitability of cheap and disposable fused silica optical fibers coated with 100 μm polydimethylsiloxane (PDMS) by sampling the pheromone of two noctuid moths, Heliothis virescens and Heliothis subflexa. By rubbing the disposable PDMS fibers over the pheromone glands of females that had called for at least 15 minutes and subsequently extracting the PDMS fibers in hexane, we collected all known pheromone compounds, and we found a strong positive correlation for most pheromone compounds between the disposable PDMS fiber rubs and the corresponding gland extracts of the same females. When comparing this method to volatile collections and the corresponding gland extracts, we generally found comparable percentages between the three techniques, with some differences that likely stem from the chemical properties of the individual pheromone compounds. Hexane extraction of cheap, disposable, PDMS coated fused silica optical fibers allows for sampling large quantities of individual females in a short time, eliminates the need for immediate sample analysis, and enables to use the same sample for multiple chemical analyses.
Lievers, Rik; Groot, Astrid T.
2016-01-01
In the past decades, the sex pheromone composition in female moths has been analyzed by different methods, ranging from volatile collections to gland extractions, which all have some disadvantage: volatile collections can generally only be conducted on (small) groups of females to detect the minor pheromone compounds, whereas gland extractions are destructive. Direct-contact SPME overcomes some of these disadvantages, but is expensive, the SPME fiber coating can be damaged due to repeated usage, and samples need to be analyzed relatively quickly after sampling. In this study, we assessed the suitability of cheap and disposable fused silica optical fibers coated with 100 μm polydimethylsiloxane (PDMS) by sampling the pheromone of two noctuid moths, Heliothis virescens and Heliothis subflexa. By rubbing the disposable PDMS fibers over the pheromone glands of females that had called for at least 15 minutes and subsequently extracting the PDMS fibers in hexane, we collected all known pheromone compounds, and we found a strong positive correlation for most pheromone compounds between the disposable PDMS fiber rubs and the corresponding gland extracts of the same females. When comparing this method to volatile collections and the corresponding gland extracts, we generally found comparable percentages between the three techniques, with some differences that likely stem from the chemical properties of the individual pheromone compounds. Hexane extraction of cheap, disposable, PDMS coated fused silica optical fibers allows for sampling large quantities of individual females in a short time, eliminates the need for immediate sample analysis, and enables to use the same sample for multiple chemical analyses. PMID:27533064
A method for detecting fungal contaminants in wall cavities.
Spurgeon, Joe C
2003-01-01
This article describes a practical method for detecting the presence of both fungal spores and culturable fungi in wall cavities. Culturable fungi were collected in 25 mm cassettes containing 0.8 microm mixed cellulose ester filters using aggressive sampling conditions. Both culturable fungi and fungal spores were collected in modified slotted-disk cassettes. The sample volume was 4 L. The filters were examined microscopically and dilution plated onto multiple culture media. Collecting airborne samples in filter cassettes was an effective method for assessing wall cavities for fungal contaminants, especially because this method allowed the sample to be analyzed by both microscopy and culture media. Assessment criteria were developed that allowed the sample results to be used to classify wall cavities as either uncontaminated or contaminated. As a criterion, wall cavities with concentrations of culturable fungi below the limit of detection (LOD) were classified as uncontaminated, whereas those cavities with detectable concentrations of culturable fungi were classified as contaminated. A total of 150 wall cavities was sampled as part of a field project. The concentrations of culturable fungi were below the LOD in 34% of the samples, whereas Aspergillus and/or Penicillium were the only fungal genera detected in 69% of the samples in which culturable fungi were detected. Spore counting resulted in the detection of Stachybotrys-like spores in 25% of the samples that were analyzed, whereas Stachybotrys chartarum colonies were only detected on 2% of malt extract agar plates and on 6% of corn meal agar plates.
Light, Thomas D.; Schmidt, Jeanine M.
2011-01-01
Mineralized and altered rock samples collected from the northern Talkeetna Mountains, Alaska, were analyzed by two different inductively coupled plasma atomic-emission spectrometry (ICP-AES) methods for as many as 44 elements; by fire assay and either direct-coupled plasma (DCP) or atomic absorption spectrophotometry (AAS) for gold (Au); by cold vapor atomic absorption (CVAA) for mercury (Hg); and by irradiated neutron activation analysis (INAA) for tungsten (W). The analytical results showed that some samples contain high values of multiple elements and may be potential indicators of hydrothermal mineralization in the area.
Comparison of Techniques for Sampling Adult Necrophilous Insects From Pig Carcasses.
Cruise, Angela; Hatano, Eduardo; Watson, David W; Schal, Coby
2018-02-06
Studies of the pre-colonization interval and mechanisms driving necrophilous insect ecological succession depend on effective sampling of adult insects and knowledge of their diel and successional activity patterns. The number of insects trapped, their diversity, and diel periodicity were compared with four sampling methods on neonate pigs. Sampling method, time of day and decomposition age of the pigs significantly affected the number of insects sampled from pigs. We also found significant interactions of sampling method and decomposition day, time of sampling and decomposition day. No single method was superior to the other methods during all three decomposition days. Sampling times after noon yielded the largest samples during the first 2 d of decomposition. On day 3 of decomposition however, all sampling times were equally effective. Therefore, to maximize insect collections from neonate pigs, the method used to sample must vary by decomposition day. The suction trap collected the most species-rich samples, but sticky trap samples were the most diverse, when both species richness and evenness were factored into a Shannon diversity index. Repeated sampling during the noon to 18:00 hours period was most effective to obtain the maximum diversity of trapped insects. The integration of multiple sampling techniques would most effectively sample the necrophilous insect community. However, because all four tested methods were deficient at sampling beetle species, future work should focus on optimizing the most promising methods, alone or in combinations, and incorporate hand-collections of beetles. © The Author(s) 2018. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Whitton, Clare; Gay, Gibson Ming Wei; Lim, Raymond Boon Tar; Tan, Linda Wei Lin; Lim, Wei-Yen; van Dam, Rob M
2016-08-01
The collection of 24-h urine samples for the estimation of sodium intake is burdensome, and the utility of spot urine samples in Southeast Asian populations is unclear. We aimed to assess the validity of prediction equations with the use of spot urine concentrations. A sample of 144 Singapore residents of Chinese, Malay, and Indian ethnicity aged 18-79 y were recruited from the Singapore Health 2 Study conducted in 2014. Participants collected urine for 24 h in multiple small bottles on a single day. To determine the optimal collection time for a spot urine sample, a 1-mL sample was taken from a random bottle collected in the morning, afternoon, and evening. Published equations and a newly derived equation were used to predict 24-h sodium excretion from spot urine samples. The mean ± SD concentration of sodium from the 24-h urine sample was 125 ± 53.4 mmol/d, which is equivalent to 7.2 ± 3.1 g salt. Bland-Altman plots showed good agreement at the group level between estimated and actual 24-h sodium excretion, with biases for the morning period of -3.5 mmol (95% CI: -14.8, 7.8 mmol; new equation) and 1.46 mmol (95% CI: -10.0, 13.0 mmol; Intersalt equation). A larger bias of 25.7 mmol (95% CI: 12.2, 39.3 mmol) was observed for the Tanaka equation in the morning period. The prediction accuracy did not differ significantly for spot urine samples collected at different times of the day or at a random time of day (P = 0.11-0.76). This study suggests that the application of both our own newly derived equation and the Intersalt equation to spot urine concentrations may be useful in predicting group means for 24-h sodium excretion in urban Asian populations. © 2016 American Society for Nutrition.
Method and apparatus for fiber optic multiple scattering suppression
NASA Technical Reports Server (NTRS)
Ackerson, Bruce J. (Inventor)
2000-01-01
The instant invention provides a method and apparatus for use in laser induced dynamic light scattering which attenuates the multiple scattering component in favor of the single scattering component. The preferred apparatus utilizes two light detectors that are spatially and/or angularly separated and which simultaneously record the speckle pattern from a single sample. The recorded patterns from the two detectors are then cross correlated in time to produce one point on a composite single/multiple scattering function curve. By collecting and analyzing cross correlation measurements that have been taken at a plurality of different spatial/angular positions, the signal representative of single scattering may be differentiated from the signal representative of multiple scattering, and a near optimum detector separation angle for use in taking future measurements may be determined.
Rossini, Giada; Gaibani, Paolo; Vocale, Caterina; Cagarelli, Roberto; Landini, Maria Paola
2017-09-01
The capability to detect ZIKV RNA is of crucial importance for cases confirmation. However, due to the short-lived viremia, the detection of ZIKV RNA in plasma/serum is challenging for samples collected more than one week after onset of clinical illness. We compared the window time and detection rate of ZIKV RNA in different specimen types (plasma, whole blood and urine) collected simultaneously at several times post-symptom onset. We examined the presence of ZIKV RNA in matched specimens of whole blood, plasma and urine collected in the same date (3-28 days after symptom onset) from 10 ZIKV infected patients. ZIKV RNA was found in plasma as late as 10 days after symptoms onset and tested positive in all 5 (100%) and in 2 of 6 (33,3%) plasma samples collected 1-5 and 6-10 days after symptoms onset, respectively. ZIKV RNA was positive in urine through the 21st day after symptom onset; the detection rate of ZIKV RNA in urine samples was 100% (11/11) for samples collected 1-10 days from symptoms onset, decreasing at later times of sampling. The detection rate of ZIKV RNA in whole blood was comparable to that in urine samples but extended the window of detection of ZIKV RNA up to 26 days after symptom onset. Our results highlight the usefulness of simultaneously testing multiple specimen types in order to extend the rate and the time frame of ZIKV RNA detection, increasing the possibility of cases confirmation through direct diagnosis in convalescence-phase of infection, supplementing serological data which are often difficult to interpret. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
Stachowiak, Jeanne C; Shugard, Erin E; Mosier, Bruce P; Renzi, Ronald F; Caton, Pamela F; Ferko, Scott M; Van de Vreugde, James L; Yee, Daniel D; Haroldsen, Brent L; VanderNoot, Victoria A
2007-08-01
For domestic and military security, an autonomous system capable of continuously monitoring for airborne biothreat agents is necessary. At present, no system meets the requirements for size, speed, sensitivity, and selectivity to warn against and lead to the prevention of infection in field settings. We present a fully automated system for the detection of aerosolized bacterial biothreat agents such as Bacillus subtilis (surrogate for Bacillus anthracis) based on protein profiling by chip gel electrophoresis coupled with a microfluidic sample preparation system. Protein profiling has previously been demonstrated to differentiate between bacterial organisms. With the goal of reducing response time, multiple microfluidic component modules, including aerosol collection via a commercially available collector, concentration, thermochemical lysis, size exclusion chromatography, fluorescent labeling, and chip gel electrophoresis were integrated together to create an autonomous collection/sample preparation/analysis system. The cycle time for sample preparation was approximately 5 min, while total cycle time, including chip gel electrophoresis, was approximately 10 min. Sensitivity of the coupled system for the detection of B. subtilis spores was 16 agent-containing particles per liter of air, based on samples that were prepared to simulate those collected by wetted cyclone aerosol collector of approximately 80% efficiency operating for 7 min.
ERIC Educational Resources Information Center
Thompson, Bruce
The relationship between analysis of variance (ANOVA) methods and their analogs (analysis of covariance and multiple analyses of variance and covariance--collectively referred to as OVA methods) and the more general analytic case is explored. A small heuristic data set is used, with a hypothetical sample of 20 subjects, randomly assigned to five…
Matching data on sediment contaminants and macroinfauna from 1,349 samples collected in estuaries along the U.S. Atlantic and Gulf of Mexico coasts were used to estimate risks of bioeffects from multiple-contaminant exposure. Sediment contamination was expressed as the mean ratio...
ERIC Educational Resources Information Center
Beach, Paul; Thier, Michael; Lench, Sarah Collins; Coleman, Matt
2015-01-01
"Understanding Entry-Level Courses in American Institutions of Higher Education" outlines a study conducted by EPIC that empirically identifies the characteristics of work at the college- and career-readiness level in English/language arts, science, and social sciences courses. Using a previously collected national sample of over two…
Sources of carbonaceous PM2.5 were quantified in downtown Cleveland, OH and Chippewa Lake, OH located ~40 miles southwest of Cleveland during the Cleveland Multiple Air Pollutant Study (CMAPS). PM2.5 filter samples were collected daily during July-August 200...
Marinho, Paula Eillanny Silva; Bretas de Oliveira, Danilo; Candiani, Talitah Michel Sanchez; Crispim, Ana Paula Correia; Alvarenga, Pedro Paulo Martins; Castro, Fabrizia Cristina Dos Santos; Abrahão, Jonatas Santos; Rios, Maria; Coimbra, Roney Santos; Kroon, Erna Geessien
2017-01-01
To determine the causes of viral meningitis, we analyzed 22 cerebrospinal fluid samples collected during the 2014-2015 dengue epidemics in Brazil. We identified 3 serotypes of dengue virus (DENV-1, -2, and -3), as well as co-infection with 2 or 3 serotypes. We also detected the Asian II genotype of DENV-2.
An assessment of re-randomization methods in bark beetle (Scolytidae) trapping bioassays
Christopher J. Fettig; Christopher P. Dabney; Stepehen R. McKelvey; Robert R. Borys
2006-01-01
Numerous studies have explored the role of semiochemicals in the behavior of bark beetles (Scolytidae). Multiple funnel traps are often used to elucidate these behavioral responses. Sufficient sample sizes are obtained by using large numbers of traps to which treatments are randomly assigned once, or by frequent collection of trap catches and subsequent re-...
ERIC Educational Resources Information Center
Kiwanuka, Henry Nsubuga; Van Damme, Jan; Van Den Noortgate, Wim; Anumendem, Dickson Nkafu; Vanlaar, Gudrun; Reynolds, Chandra; Namusisi, Speranza
2017-01-01
This study investigated the effects of student and classroom characteristics on math self-confidence, perceived usefulness, and enjoyment of mathematics as multiple outcomes. A sample of 7th-grade students from 78 classes of 49 schools was studied. The data were collected using, among other instruments, an attitude questionnaire. The results of…
He, Dan; Kuhn, David; Parida, Laxmi
2016-06-15
Given a set of biallelic molecular markers, such as SNPs, with genotype values encoded numerically on a collection of plant, animal or human samples, the goal of genetic trait prediction is to predict the quantitative trait values by simultaneously modeling all marker effects. Genetic trait prediction is usually represented as linear regression models. In many cases, for the same set of samples and markers, multiple traits are observed. Some of these traits might be correlated with each other. Therefore, modeling all the multiple traits together may improve the prediction accuracy. In this work, we view the multitrait prediction problem from a machine learning angle: as either a multitask learning problem or a multiple output regression problem, depending on whether different traits share the same genotype matrix or not. We then adapted multitask learning algorithms and multiple output regression algorithms to solve the multitrait prediction problem. We proposed a few strategies to improve the least square error of the prediction from these algorithms. Our experiments show that modeling multiple traits together could improve the prediction accuracy for correlated traits. The programs we used are either public or directly from the referred authors, such as MALSAR (http://www.public.asu.edu/~jye02/Software/MALSAR/) package. The Avocado data set has not been published yet and is available upon request. dhe@us.ibm.com. © The Author 2016. Published by Oxford University Press.
Evaluating single-pass catch as a tool for identifying spatial pattern in fish distribution
Bateman, Douglas S.; Gresswell, Robert E.; Torgersen, Christian E.
2005-01-01
We evaluate the efficacy of single-pass electrofishing without blocknets as a tool for collecting spatially continuous fish distribution data in headwater streams. We compare spatial patterns in abundance, sampling effort, and length-frequency distributions from single-pass sampling of coastal cutthroat trout (Oncorhynchus clarki clarki) to data obtained from a more precise multiple-pass removal electrofishing method in two mid-sized (500–1000 ha) forested watersheds in western Oregon. Abundance estimates from single- and multiple-pass removal electrofishing were positively correlated in both watersheds, r = 0.99 and 0.86. There were no significant trends in capture probabilities at the watershed scale (P > 0.05). Moreover, among-sample variation in fish abundance was higher than within-sample error in both streams indicating that increased precision of unit-scale abundance estimates would provide less information on patterns of abundance than increasing the fraction of habitat units sampled. In the two watersheds, respectively, single-pass electrofishing captured 78 and 74% of the estimated population of cutthroat trout with 7 and 10% of the effort. At the scale of intermediate-sized watersheds, single-pass electrofishing exhibited a sufficient level of precision to be effective in detecting spatial patterns of cutthroat trout abundance and may be a useful tool for providing the context for investigating fish-habitat relationships at multiple scales.
Neighborhood Structural Inequality, Collective Efficacy, and Sexual Risk Behavior among Urban Youth
BROWNING, CHRISTOPHER R.; BURRINGTON, LORI A.; LEVENTHAL, TAMA; BROOKS-GUNN, JEANNE
2011-01-01
We draw on collective efficacy theory to extend a contextual model of early adolescent sexual behavior. Specifically, we hypothesize that neighborhood structural disadvantage—as measured by levels of concentrated poverty, residential instability, and aspects of immigrant concentration—and diminished collective efficacy have consequences for the prevalence of early adolescent multiple sexual partnering. Findings from random effects multinomial logistic regression models of the number of sexual partners among a sample of youth, age 11 to 16, from the Project on Human Development in Chicago Neighborhoods (N = 768) reveal evidence of neighborhood effects on adolescent higher-risk sexual activity. Collective efficacy is negatively associated with having two or more sexual partners versus one (but not zero versus one) sexual partner. The effect of collective efficacy is dependent upon age: The regulatory effect of collective efficacy increases for older adolescents. PMID:18771063
Characterization of Qatar's surface carbonates for CO2 capture and thermochemical energy storage
NASA Astrophysics Data System (ADS)
Kakosimos, Konstantinos E.; Al-Haddad, Ghadeer; Sakellariou, Kyriaki G.; Pagkoura, Chrysa; Konstandopoulos, Athanasios G.
2017-06-01
Samples of surface carbonates were collected from three different areas of the Qatar peninsula. We employed material characterization techniques to examine the morphology and composition of the samples, while their CO2 capture capacity was assessed via multiple successive calcination-carbonation cycles. Our samples were mainly calcite and dolomite based. Calcite samples showed higher initial capacity of around 11 mmol CO2 g-1 which decayed rapidly to less than 2 mmol CO2 g-1. On the other hand, dolomite samples showed an excellent stability (˜15 cycles) with a capacity of 6 mmol CO2 g-1. The performance of the dolomite samples is better compared to other similar natural samples, from literature. A promising result for future studies towards improving their performance by physical and chemical modification.
Schimpf, Karen J.; Meek, Claudia C.; Leff, Richard D.; Phelps, Dale L.; Schmitz, Daniel J.; Cordle, Christopher T.
2015-01-01
Inositol is a six-carbon sugar alcohol and is one of nine biologically significant isomers of hexahydroxycyclohexane. Myo-inositol is the primary biologically active form and is present in higher concentrations in the fetus and newborn than in adults. It is currently being examined for the prevention of retinopathy of prematurity in newborn preterm infants. A robust method for quantifying myo-inositol (MI), D-chiro-inositol (DCI) and 1,5-anhydro-D-sorbitol (ADS) in very small-volume (25 μL) urine, blood serum and/or plasma samples was developed. Using a multiple-column, multiple mobile phase liquid chromatographic system with electrochemical detection, the method was validated with respect to (a) selectivity, (b) accuracy/recovery, (c) precision/reproducibility, (d) sensitivity, (e) stability and (f) ruggedness. The standard curve was linear and ranged from 0.5 to 30 mg/L for each of the three analytes. Above-mentioned performance measures were within acceptable limits described in the Food and Drug Administration’s Guidance for Industry: Bioanalytical Method Validation. The method was validated using blood serum and plasma collected using four common anticoagulants, and also by quantifying the accuracy and sensitivity of MI measured in simulated urine samples recovered from preterm infant diaper systems. The method performs satisfactorily measuring the three most common inositol isomers on 25 μL clinical samples of serum, plasma milk, and/or urine. Similar performance is seen testing larger volume samples of infant formulas and infant formula ingredients. MI, ADS and DCI may be accurately tested in urine samples collected from five different preterm infant diapers if the urine volume is greater than 2–5 mL. PMID:26010453
Bartholomay, Roy C.; Twining, Brian V.
2010-01-01
From 2005 to 2008, the U.S. Geological Survey's Idaho National Laboratory (INL) Project office, in cooperation with the U.S. Department of Energy, collected water-quality samples from multiple water-bearing zones in the eastern Snake River Plain aquifer. Water samples were collected from six monitoring wells completed in about 350-700 feet of the upper part of the aquifer, and the samples were analyzed for major ions, selected trace elements, nutrients, selected radiochemical constituents, and selected stable isotopes. Each well was equipped with a multilevel monitoring system containing four to seven sampling ports that were each isolated by permanent packer systems. The sampling ports were installed in aquifer zones that were highly transmissive and that represented the water chemistry of the top four to five model layers of a steady-state and transient groundwater-flow model. The model's water chemistry and particle-tracking simulations are being used to better define movement of wastewater constituents in the aquifer. The results of the water chemistry analyses indicated that, in each of four separate wells, one zone of water differed markedly from the other zones in the well. In four wells, one zone to as many as five zones contained radiochemical constituents that originated from wastewater disposal at selected laboratory facilities. The multilevel sampling systems are defining the vertical distribution of wastewater constituents in the eastern Snake River Plain aquifer and the concentrations of wastewater constituents in deeper zones in wells Middle 2051, USGS 132, and USGS 103 support the concept of groundwater flow deepening in the southwestern part of the INL.
Quality assured measurements of animal building emissions: gas concentrations.
Heber, Albert J; Ni, Ji-Qin; Lim, Teng T; Tao, Pei-Chun; Schmidt, Amy M; Koziel, Jacek A; Beasley, David B; Hoff, Steven J; Nicolai, Richard E; Jacobson, Larry D; Zhang, Yuanhui
2006-10-01
Comprehensive field studies were initiated in 2002 to measure emissions of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2), methane (CH4), nonmethane hydrocarbons (NMHC), particulate matter <10 microm in diameter, and total suspended particulate from swine and poultry production buildings in the United States. This paper focuses on the quasicontinuous gas concentration measurement at multiple locations among paired barns in seven states. Documented principles, used in air pollution monitoring at industrial sources, were applied in developing quality assurance (QA) project plans for these studies. Air was sampled from multiple locations with each gas analyzed with one high quality commercial gas analyzer that was located in an environmentally controlled on-farm instrument shelter. A nominal 4 L/min gas sampling system was designed and constructed with Teflon wetted surfaces, bypass pumping, and sample line flow and pressure sensors. Three-way solenoids were used to automatically switch between multiple gas sampling lines with > or =10 min sampling intervals. Inside and outside gas sampling probes were between 10 and 115 m away from the analyzers. Analyzers used chemiluminescence, fluorescence, photoacoustic infrared, and photoionization detectors for NH3, H2S, CO2, CH4, and NMHC, respectively. Data were collected using personal computer-based data acquisition hardware and software. This paper discusses the methodology of gas concentration measurements and the unique challenges that livestock barns pose for achieving desired accuracy and precision, data representativeness, comparability and completeness, and instrument calibration and maintenance.
Simultaneous monitoring of faecal indicators and harmful algae using an in-situ autonomous sensor.
Yamahara, K M; Demir-Hilton, E; Preston, C M; Marin, R; Pargett, D; Roman, B; Jensen, S; Birch, J M; Boehm, A B; Scholin, C A
2015-08-01
Faecal indicator bacteria (FIB) and harmful algal blooms (HABs) threaten the health and the economy of coastal communities worldwide. Emerging automated sampling technologies combined with molecular analytical techniques could enable rapid detection of micro-organisms in-situ, thereby improving resource management and public health decision-making. We evaluated this concept using a robotic device, the Environmental Sample Processor (ESP). The ESP automates in-situ sample collection, nucleic acid extraction and molecular analyses. Here, the ESP measured and reported concentrations of FIB (Enterococcus spp.), a microbial source-tracking marker (human-specific Bacteriodales) and a HAB species (Psuedo-nitzschia spp.) over a 45-day deployment on the Santa Cruz Municipal Wharf (Santa Cruz, CA, USA). Both FIB and HABs were enumerated from single in-situ collected water samples. The in-situ qPCR efficiencies ranged from 86% to 105%, while the limit of quantifications during the deployment was 10 copies reaction(-1) . No differences were observed in the concentrations of enterococci, the human-specific marker in Bacteroidales spp., and P. australis between in-situ collected sample and traditional hand sampling methods (P > 0·05). Analytical results were Internet-accessible within hours of sample collection, demonstrating the feasibility of same-day public notification of current water quality conditions. This study presents the first report of in-situ qPCR enumeration of both faecal indicators and harmful algal species in coastal marine waters. We utilize a robotic device for in-situ quantification of enterococci, the human-specific marker in Bacteriodales and Pseudo-nitzschia spp. from the same water samples collected and processed in-situ. The results demonstrate that rapid, in-situ monitoring can be utilized to identify and quantify multiple health-relevant micro-organisms important in water quality monitoring and that this monitoring can be used to inform same-day notifications. © 2015 The Society for Applied Microbiology.
Patterson, Kristine B.; Malone, Stephanie A.; Shaheen, Nicholas J.; Asher Prince, Heather M.; Dumond, Julie B.; Spacek, Melissa B.; Heidt, Paris E.; Cohen, Myron S.; Kashuba, Angela D. M.
2011-01-01
Background. Antiretroviral pharmacology in seminal plasma (SP) and rectal tissue (RT) may provide insight into antiretroviral resistance and the prevention of sexual transmission of human immunodeficiency virus (HIV). Saliva may be of utility for noninvasively measuring adherence. Methods. A pharmacokinetic study was performed in 12 HIV-negative men receiving maraviroc 300 mg twice daily for 8 days. Seven time-matched pairs of blood plasma (BP) and saliva samples were collected over 12 h on day 1 (PK1) and days 7 and 8 (PK2). One RT sample from each subject was collected during PK1 and PK2. Two SP samples were collected from each subject during PK1, and 6 SP samples were collected from each subject during PK2. Results. SP AUCs were ∼50% lower than BP. However, protein binding in SP ranged from 4% to 25%, resulting in protein-free concentrations >2-fold higher than BP. RT AUCs were 7.5- to 26-fold higher than BP. Maraviroc saliva AUCs were ∼70% lower than BP, but saliva concentrations correlated with BP (r2 = 0.58). Conclusions. More pharmacologically available maraviroc was found in SP than BP. High RT concentrations are promising for preventing rectal HIV acquisition. Saliva correlation with BP suggests that this may be useful for monitoring adherence. Clinical Trials Registration. NCT00775294. PMID:21502084
Handwashing and antiseptic-containing soaps in hospital
Jarvis, J. D.; Wynne, C. D.; Enwright, L.; Williams, J. D.
1979-01-01
Two aspects of handwashing in hospital were considered. A study was carried out to examine the contamination of bar soap and containers, and the use of antiseptic soaps in reducing the resident flora of the skin. Swabs were collected from soap dishes on six wards and from a bacteriology laboratory on four consecutive days. The unmedicated bar soap was replaced by bar soap containing 2·5% povidone-iodine, and further swabs were collected over a period of seven days. Ninety-two isolates from 48 samples were obtained when unmedicated bar soap was used, and nine isolates from 42 samples when povidone-iodine (Betadine) soap was substituted. The number of organisms recovered when povidone-iodine soap was used was much reduced, and Pseudomonas spp were recovered in low numbers on only one occasion. Six laboratory workers took part in a study to compare bar soap with other agents—povidone-iodine soap, povidone-iodine surgical scrub, povidone-iodine alcoholic solution, chlorhexidine surgical scrub, and alcoholic chlorhexidine. Samples were collected after standard washes and after surgical gloves had been worn for 90 minutes. The effect of multiple washes was assessed by samples collected after six washes with the agent under study (three per day) followed by 90 minutes wearing surgical gloves. The average percentage reduction in normal flora obtained indicated that alcoholic chlorhexidine was superior to the other agents. PMID:500840
Building an Internet of Samples: The Australian Contribution
NASA Astrophysics Data System (ADS)
Wyborn, Lesley; Klump, Jens; Bastrakova, Irina; Devaraju, Anusuriya; McInnes, Brent; Cox, Simon; Karssies, Linda; Martin, Julia; Ross, Shawn; Morrissey, John; Fraser, Ryan
2017-04-01
Physical samples are often the ground truth to research reported in the scientific literature across multiple domains. They are collected by many different entities (individual researchers, laboratories, government agencies, mining companies, citizens, museums, etc.). Samples must be curated over the long-term to ensure both that their existence is known, and to allow any data derived from them through laboratory and field tests to be linked to the physical samples. For example, having unique identifiers that link back ground truth data on the original sample helps calibrate large volumes of remotely sensed data. Access to catalogues of reliably identified samples from several collections promotes collaboration across all Earth Science disciplines. It also increases the cost effectiveness of research by reducing the need to re-collect samples in the field. The assignment of web identifiers to the digital representations of these physical objects allows us to link to data, literature, investigators and institutions, thus creating an "Internet of Samples". An Australian implementation of the "Internet of Samples" is using the IGSN (International Geo Sample Number, http://igsn.github.io) to identify samples in a globally unique and persistent way. IGSN was developed in the solid earth science community and is recommended for sample identification by the Coalition for Publishing Data in the Earth and Space Sciences (COPDESS). IGSN is interoperable with other persistent identifier systems such as DataCite. Furthermore, the basic IGSN description metadata schema is compatible with existing schemas such as OGC Observations and Measurements (O&M) and DataCite Metadata Schema which makes crosswalks to other metadata schemas easy. IGSN metadata is disseminated through the Open Archives Initiative Protocol for Metadata Harvesting (OAI-PMH) allowing it to be aggregated in other applications such as portals (e.g. the Australian IGSN catalogue http://igsn2.csiro.au). The metadata is available in more than one format. The software for IGSN web services is based on components developed for DataCite and adapted to the specific requirements of IGSN. This cooperation in open source development ensures sustainable implementation and faster turnaround times for updates. IGSN, in particular in its Australian implementation, is characterised by a federated approach to system architecture and organisational governance giving it the necessary flexibility to adapt to particular local practices within multiple domains, whilst maintaining an overarching international standard. The three current IGSN allocation agents in Australia: Geoscience Australia, CSIRO and Curtin University, represent different sectors. Through funding from the Australian Research Data Services Program they have combined to develop a common web portal that allows discovery of physical samples and sample collections at a national level.International governance then ensures we can link to an international community but at the same time act locally to ensure the services offered are relevant to the needs of Australian researchers. This flexibility aids the integration of new disciplines into a global community of a physical samples information network.
Proposed BioRepository platform solution for the ALS research community.
Sherman, Alex; Bowser, Robert; Grasso, Daniela; Power, Breen; Milligan, Carol; Jaffa, Matthew; Cudkowicz, Merit
2011-01-01
ALS is a rare disorder whose cause and pathogenesis is largely unknown ( 1 ). There is a recognized need to develop biomarkers for ALS to better understand the disease, expedite diagnosis and to facilitate therapy development. Collaboration is essential to obtain a sufficient number of samples to allow statistically meaningful studies. The availability of high quality biological specimens for research purposes requires the development of standardized methods for collection, long-term storage, retrieval and distribution of specimens. The value of biological samples to scientists and clinicians correlates with the completeness and relevance of phenotypical and clinical information associated with the samples ( 2 , 3 ). While developing a secure Web-based system to manage an inventory of multi-site BioRepositories, algorithms were implemented to facilitate ad hoc parametric searches across heterogeneous data sources that contain data from clinical trials and research studies. A flexible schema for a barcode label was introduced to allow association of samples to these data. The ALSBank™ BioRepository platform solution for managing biological samples and associated data is currently deployed by the Northeast ALS Consortium (NEALS). The NEALS Consortium and the Massachusetts General Hospital (MGH) Neurology Clinical Trials Unit (NCTU) support a network of multiple BioBanks, thus allowing researchers to take advantage of a larger specimen collection than they might have at an individual institution. Standard operating procedures are utilized at all collection sites to promote common practices for biological sample integrity, quality control and associated clinical data. Utilizing this platform, we have created one of the largest virtual collections of ALS-related specimens available to investigators studying ALS.
Morin, Alexander M; Gatev, Evan; McEwen, Lisa M; MacIsaac, Julia L; Lin, David T S; Koen, Nastassja; Czamara, Darina; Räikkönen, Katri; Zar, Heather J; Koenen, Karestan; Stein, Dan J; Kobor, Michael S; Jones, Meaghan J
2017-01-01
Cord blood is a commonly used tissue in environmental, genetic, and epigenetic population studies due to its ready availability and potential to inform on a sensitive period of human development. However, the introduction of maternal blood during labor or cross-contamination during sample collection may complicate downstream analyses. After discovering maternal contamination of cord blood in a cohort study of 150 neonates using Illumina 450K DNA methylation (DNAm) data, we used a combination of linear regression and random forest machine learning to create a DNAm-based screening method. We identified a panel of DNAm sites that could discriminate between contaminated and non-contaminated samples, then designed pyrosequencing assays to pre-screen DNA prior to being assayed on an array. Maternal contamination of cord blood was initially identified by unusual X chromosome DNA methylation patterns in 17 males. We utilized our DNAm panel to detect contaminated male samples and a proportional amount of female samples in the same cohort. We validated our DNAm screening method on an additional 189 sample cohort using both pyrosequencing and DNAm arrays, as well as 9 publically available cord blood 450K data sets. The rate of contamination varied from 0 to 10% within these studies, likely related to collection specific methods. Maternal blood can contaminate cord blood during sample collection at appreciable levels across multiple studies. We have identified a panel of markers that can be used to identify this contamination, either post hoc after DNAm arrays have been completed, or in advance using a targeted technique like pyrosequencing.
Quadrupole ion traps and trap arrays: geometry, material, scale, performance.
Ouyang, Z; Gao, L; Fico, M; Chappell, W J; Noll, R J; Cooks, R G
2007-01-01
Quadrupole ion traps are reviewed, emphasizing recent developments, especially the investigation of new geometries, guided by multiple particle simulations such as the ITSIM program. These geometries include linear ion traps (LITs) and the simplified rectilinear ion trap (RIT). Various methods of fabrication are described, including the use of rapid prototyping apparatus (RPA), in which 3D objects are generated through point-by-point laser polymerization. Fabrication in silicon using multilayer semi-conductor fabrication techniques has been used to construct arrays of micro-traps. The performance of instruments containing individual traps as well as arrays of traps of various sizes and geometries is reviewed. Two types of array are differentiated. In the first type, trap arrays constitute fully multiplexed mass spectrometers in which multiple samples are examined using multiple sources, analyzers and detectors, to achieve high throughput analysis. In the second, an array of individual traps acts collectively as a composite trap to increase trapping capacity and performance for a single sample. Much progress has been made in building miniaturized mass spectrometers; a specific example is a 10 kg hand-held tandem mass spectrometer based on the RIT mass analyzer. The performance of this instrument in air and water analysis, using membrane sampling, is described.
Hydraulically controlled discrete sampling from open boreholes
Harte, Philip T.
2013-01-01
Groundwater sampling from open boreholes in fractured-rock aquifers is particularly challenging because of mixing and dilution of fluid within the borehole from multiple fractures. This note presents an alternative to traditional sampling in open boreholes with packer assemblies. The alternative system called ZONFLO (zonal flow) is based on hydraulic control of borehole flow conditions. Fluid from discrete fractures zones are hydraulically isolated allowing for the collection of representative samples. In rough-faced open boreholes and formations with less competent rock, hydraulic containment may offer an attractive alternative to physical containment with packers. Preliminary test results indicate a discrete zone can be effectively hydraulically isolated from other zones within a borehole for the purpose of groundwater sampling using this new method.
Characterization and Delivery of Hanford High-Level Radioactive Waste Slurry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thien, Michael G.; Denslow, Kayte M.; Lee, K. P.
2014-11-15
Two primary challenges to characterizing Hanford’s high-level radioactive waste slurry prior to transfer to a treatment facility are the ability to representatively sample million-gallon tanks and to estimate the critical velocity of the complex slurry. Washington River Protection Solutions has successfully demonstrated a sampling concept that minimizes sample errors by collecting multiple sample increments from a sample loop where the mixed tank contents are recirculated. Pacific Northwest National Laboratory has developed and demonstrated an ultrasonic-based Pulse-Echo detection device that is capable of detecting a stationary settled bed of solids in a pipe with flowing slurry. These two concepts are essentialmore » elements of a feed delivery strategy that drives the Hanford clean-up mission.« less
Korfmacher, Walter; Luo, Yongyi; Ho, Stacy; Sun, Wei; Shen, Liduo; Wang, Jie; Wu, Zhongtao; Guo, Yang; Snow, Gregory; O'Shea, Thomas
2015-01-01
Serial sampling methods have been used for rat pharmacokinetic (PK) studies for over 20 years. Currently, it is still common to take 200-250 μL of blood at each timepoint when performing a PK study in rats and using serial sampling. While several techniques have been employed for collecting blood samples from rats, there is only limited published data to compare these methods. Recently, microsampling (≤ 50 μL) techniques have been reported as an alternative process for collecting blood samples from rats. In this report, five compounds were dosed orally into rats. For three proprietary compounds, jugular vein cannula (JVC) sampling was used to collect whole blood and plasma samples and capillary microsampling (CMS) was used to collect blood samples from the tail vein of the same animal. For the two other compounds, marketed drugs fluoxetine and glipizide, JVC sampling was used to collect both whole blood and blood CMS samples while tail-vein sampling from the same rats was also used to collect both whole blood and blood CMS samples. For the three proprietary compounds, the blood AUC as well as the blood concentration-time profile that were obtained from the tail vein were different from those obtained via JVC sampling. For fluoxetine, the blood total exposure (AUC) was not statistically different when comparing tail-vein sampling to JVC sampling, however the blood concentration-time profile that was obtained from the tail vein was different than the one obtained from JVC sampling. For glipizide, the blood AUC and concentration-time profile were not statistically different when comparing the tail-vein sampling to the JVC sampling. For both fluoxetine and glipizide, the blood concentration profiles obtained from CMS were equivalent to the blood concentration profiles obtained from the standard whole blood sampling, collected at the same sampling site. The data in this report provide strong evidence that blood CMS is a valuable small volume blood sampling approach for rats and that it provides results for test compound concentrations that are equivalent to those obtained from traditional whole blood sampling. The data also suggest that for some compounds, the concentration-time profile that is obtained for a test compound based on sampling from a rat tail vein may be different from that obtained from rat JVC sampling. In some cases, this shift in the concentration-time profile will result in different PK parameters for the test compound. Based on these observations, it is recommended that a consistent blood sampling method should be used for serial microsampling in discovery rat PK studies when testing multiple new chemical entities. If the rat tail vein sampling method is selected for PK screening, then conducting a bridging study on the lead compound is recommended to confirm that the rat PK obtained from JVC sampling is comparable to the tail-vein sampling. Copyright © 2015 Elsevier Inc. All rights reserved.
Tertuliani, John S.
1999-01-01
The results of a survey of macroinvertebrate communities in the Ravenna Army Ammunition Plant, were used as an indicator of disturbance in streams flowing through or near the training areas at the Plant. The data were interpreted using the Invertebrate Community Index (ICI), a multiple-metric index developed by the Ohio Environmental Protection Agency and based on the structural and functional characteristics of the macroinvertebrate community. Quantitative samples of the macroinvertebrate were collected for ICI determination from three streams South Fork Eagle Creek, Sand Creek, and Hinkley Creek flowing through the study area. These samples were collected using Hester-Dendy type artificial substrate samplers, which were placed in the streams during a 6-week sampling period, June 2 through July 15, 1998. A qualitative- dipnet sample from the natural substrates also was collected at each station on July 15, 1998, the last day of the sampling period. The macroinvertebrate communities at all three stations met the criterion designated for warmwater habitat aquatic life use, and communities at two of the three stations exceeded the criterion. The ICI scores were 42 at South Fork Eagle Creek, 50 at Sand Creek, and 48 at Hinkley Creek. The density of macroinvertebrates at South Fork Eagle Creek was 1,245 per square foot and represented 38 distinct taxa. The density at Sand Creek was 246 per square foot and represented 29 distinct taxa. The density at Hinkley Creek was 864 per square foot and represented 36 distinct taxa. Qualitative samples were also collected at 21 other sites using a D-framed dipnet. The qualitative sites encompassed three main environments: stream, pond, and swamp-wetland. All available habitat types in each environment were sampled until no new taxa were evident during coarse examination. The highest number of taxa were collected from the streams. The total number of taxa collected in streams ranged from 25 to 76; the mean was 60 and median 64. The total taxa collected from ponds ranged from 32 to 60; the mean was 42 and median 41. The total taxa collected from swamp-wetland areas ranged from 6 to 30; the mean was 20 and median 23. The results are listed in phylogenetic order in this report and establish baseline data for future studies.
Exposure of native bees foraging in an agricultural landscape to current-use pesticides.
Hladik, Michelle L; Vandever, Mark; Smalling, Kelly L
2016-01-15
The awareness of insects as pollinators and indicators of environmental quality has grown in recent years, partially in response to declines in honey bee (Apis mellifera) populations. While most pesticide research has focused on honey bees, there has been less work on native bee populations. To determine the exposure of native bees to pesticides, bees were collected from an existing research area in northeastern Colorado in both grasslands (2013-2014) and wheat fields (2014). Traps were deployed bi-monthly during the summer at each land cover type and all bees, regardless of species, were composited as whole samples and analyzed for 136 current-use pesticides and degradates. This reconnaissance approach provides a sampling of all species and represents overall pesticide exposure (internal and external). Nineteen pesticides and degradates were detected in 54 composite samples collected. Compounds detected in >2% of the samples included: insecticides thiamethoxam (46%), bifenthrin (28%), clothianidin (24%), chlorpyrifos (17%), imidacloprid (13%), fipronil desulfinyl (7%; degradate); fungicides azoxystrobin (17%), pyraclostrobin (11%), fluxapyroxad (9%), and propiconazole (9%); herbicides atrazine (19%) and metolachlor (9%). Concentrations ranged from 1 to 310 ng/g for individual pesticides. Pesticides were detected in samples collected from both grasslands and wheat fields; the location of the sample and the surrounding land cover at the 1000 m radius influenced the pesticides detected but because of a small number of temporally comparable samples, correlations between pesticide concentration and land cover were not significant. The results show native bees collected in an agricultural landscape are exposed to multiple pesticides, these results can direct future research on routes/timing of pesticide exposure and the design of future conservation efforts for pollinators. Published by Elsevier B.V.
Exposure of native bees foraging in an agricultural landscape to current-use pesticides
Hladik, Michelle; Vandever, Mark W.; Smalling, Kelly L.
2016-01-01
The awareness of insects as pollinators and indicators of environmental quality has grown in recent years, partially in response to declines in honey bee (Apis mellifera) populations. While most pesticide research has focused on honey bees, there has been less work on native bee populations. To determine the exposure of native bees to pesticides, bees were collected from an existing research area in northeastern Colorado from two land cover types: grasslands (2013-2014) and wheat fields (2014). Traps were deployed bi-monthly during the summer at each land cover type and all bees, regardless of species, were composited as whole samples and analyzed for 136 current-use pesticides and degradates. This reconnaissance approach provides a sampling of all species and represents overall pesticide exposure (internal and external). Nineteen pesticides and degradates were detected in 54 composite samples collected. Compounds detected in >10% of the samples included the insecticides thiamethoxam (46%), bifenthrin (28%), clothianidin (24%), chlorpyrifos (17%), and imidacloprid (13%), the fungicides azoxystrobin (17%), and pyraclostrobin (11%), and the herbicide atrazine (19%). Concentrations ranged from 1.1 to 312 ng/g for individual pesticides. Pesticides were detected in samples collected from both grasslands and wheat fields; the location of the sample and the surrounding land cover at the 1000 m buffer influenced the pesticides detected but because of a small number of temporally comparable samples, correlations between pesticide concentration and land cover were not significant. The results show native bees collected in both grasslands and wheat fields are exposed to multiple pesticides, these results can direct future research on routes/timing of pesticide exposure and the design of future conservation efforts for pollinators.
Johnson, Steven M.; Swanson, Robert B.
1994-01-01
Prototype stream-monitoring sites were operated during part of 1992 in the Central Nebraska Basins (CNBR) and three other study areas of the National Water-Quality Assessment (NAWQ) Program of the U.S. Geological Survey. Results from the prototype project provide information needed to operate a net- work of intensive fixed station stream-monitoring sites. This report evaluates operating procedures for two NAWQA prototype sites at Maple Creek near Nickerson and the Platte River at Louisville, eastern Nebraska. Each site was sampled intensively in the spring and late summer 1992, with less intensive sampling in midsummer. In addition, multiple samples were collected during two high- flow periods at the Maple Creek site--one early and the other late in the growing season. Water-samples analyses included determination of pesticides, nutrients, major ions, suspended sediment, and measurements of physical properties. Equipment and protocols for the water-quality sampling procedures were evaluated. Operation of the prototype stream- monitoring sites included development and comparison of onsite and laboratory sample-processing proce- dures. Onsite processing was labor intensive but allowed for immediate preservation of all sampled constituents. Laboratory processing required less field labor and decreased the risk of contamination, but allowed for no immediate preservation of the samples.
Protein Structure Classification and Loop Modeling Using Multiple Ramachandran Distributions.
Najibi, Seyed Morteza; Maadooliat, Mehdi; Zhou, Lan; Huang, Jianhua Z; Gao, Xin
2017-01-01
Recently, the study of protein structures using angular representations has attracted much attention among structural biologists. The main challenge is how to efficiently model the continuous conformational space of the protein structures based on the differences and similarities between different Ramachandran plots. Despite the presence of statistical methods for modeling angular data of proteins, there is still a substantial need for more sophisticated and faster statistical tools to model the large-scale circular datasets. To address this need, we have developed a nonparametric method for collective estimation of multiple bivariate density functions for a collection of populations of protein backbone angles. The proposed method takes into account the circular nature of the angular data using trigonometric spline which is more efficient compared to existing methods. This collective density estimation approach is widely applicable when there is a need to estimate multiple density functions from different populations with common features. Moreover, the coefficients of adaptive basis expansion for the fitted densities provide a low-dimensional representation that is useful for visualization, clustering, and classification of the densities. The proposed method provides a novel and unique perspective to two important and challenging problems in protein structure research: structure-based protein classification and angular-sampling-based protein loop structure prediction.
Fedy, B.C.; Aldridge, Cameron L.
2011-01-01
Long-term population monitoring is the cornerstone of animal conservation and management. The accuracy and precision of models developed using monitoring data can be influenced by the protocols guiding data collection. The greater sage-grouse (Centrocercus urophasianus) is a species of concern that has been monitored over decades, primarily, by counting the number of males that attend lek (breeding) sites. These lek count data have been used to assess long-term population trends and for multiple mechanistic studies. However, some studies have questioned the efficacy of lek counts to accurately identify population trends. In response, monitoring protocols were changed to have a goal of counting lek sites multiple times within a season. We assessed the influence of this change in monitoring protocols on model accuracy and precision applying generalized additive models to describe trends over time. We found that at large spatial scales including >50 leks, the absence of repeated counts within a year did not significantly alter population trend estimates or interpretation. Increasing sample size decreased the model confidence intervals. We developed a population trend model for Wyoming greater sage-grouse from 1965 to 2008, identifying significant changes in the population indices and capturing the cyclic nature of this species. Most sage-grouse declines in Wyoming occurred between 1965 and the 1990s and lek count numbers generally increased from the mid-1990s to 2008. Our results validate the combination of monitoring data collected under different protocols in past and future studies-provided those studies are addressing large-scale questions. We suggest that a larger sample of individual leks is preferable to multiple counts of a smaller sample of leks. ?? 2011 The Wildlife Society.
Naar-King, Sylvie; Parsons, Jeffrey T; Murphy, Debra A; Chen, Xinguang; Harris, D Robert; Belzer, Marvin E
2009-12-01
To determine if Healthy Choices, a motivational interviewing intervention targeting multiple risk behaviors, improved human immunodeficiency virus (HIV) viral load. A randomized, 2-group repeated measures design with analysis of data from baseline and 6- and 9-month follow-up collected from 2005 to 2007. Five US adolescent medicine HIV clinics. A convenience sample with at least 1 of 3 risk behaviors (nonadherence to HIV medications, substance abuse, and unprotected sex) was enrolled. The sample was aged 16 to 24 years and primarily African American. Of the 205 enrolled, 19 did not complete baseline data collections, for a final sample size of 186. Young people living with HIV were randomized to the intervention plus specialty care (n = 94) or specialty care alone (n = 92). The 3- and 6-month follow-up rates, respectively, were 86% and 82% for the intervention group and 81% and 73% for controls. Intervention Healthy Choices was a 4-session individual clinic-based motivational interviewing intervention delivered during a 10-week period. Motivational interviewing is a method of communication designed to elicit and reinforce intrinsic motivation for change. Outcome Measure Plasma viral load. Youth randomized to Healthy Choices showed a significant decline in viral load at 6 months postintervention compared with youth in the control condition (beta = -0.36, t = -2.15, P = .03), with those prescribed antiretroviral medications showing the lowest viral loads. Differences were no longer significant at 9 months. A motivational interviewing intervention targeting multiple risk behaviors resulted in short-term improvements in viral load for youth living with HIV. Trial Registration clinicaltrials.gov Identifier: NCT00103532.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wyrwas, Richard B.; Lamothe, Margaret E.
2013-05-30
This report describes the results of the electrochemical testing performed on tank 241-SY-102 (SY-102) grab samples that were collected in support of corrosion mitigation. The objective of the work presented here was to determine corrosion resistance of tank SY-102 to the grab samples collected using electrochemical methods up to 50°C as well as to satisfy data quality objectives. Grab samples were collected at multiple elevations from Riser 003. The electrochemical corrosion testing was planned to consist of linear polarization resistance testing (LPR) and cyclic potentiodynamic polarization (CPP) testing at 50°C. The temperature would be lowered to 40 °C and themore » test repeated if the CPP curve indicated pitting corrosion at 50°C. Ifno pitting was indicated by the CPP curve, then a duplicate scan would be repeated at 50°C to confirm the first result. The testing would be complete if the duplicate CPP scan was consistent with the first. This report contains the CPP results of the testing of grab sample 2SY-12-03 and 2SY-12-03DUP composite sample tested under these conditions. There was no indication of pitting at 50°C, and the duplicate scan was in agreement with the first scan. Since no further testing was required, a third scan with a shorter rest time was performed and is present in this report.« less
Unusual interactions above 100 TeV: A review of cosmic ray experiments with emulsion chambers
NASA Technical Reports Server (NTRS)
Yodh, D. B.
1977-01-01
A method is given for analyzing the space correlated collection of jets (gamma ray families) with energies greater than 100 TeV in Pb or Fe absorber sampled by photosensitive layers in an emulsion chamber. Events analyzed indicate large multiplicities of particles in the primary hadron-air interaction, and a marked absence of neutral pions.
ERIC Educational Resources Information Center
Bobbett, Gordon C.; And Others
The results of a study of six rural Appalachian high schools in Kentucky and Tennessee are presented. Multiple data sources were used to identify the relative effectiveness of these schools. Data were collected via administration of the: Wayson School Climate and Context Inventory to a stratified random sample of 20 faculty; Likert's…
Howard B. Stauffer; Cynthia J. Zabel; Jeffrey R. Dunk
2005-01-01
We compared a set of competing logistic regression habitat selection models for Northern Spotted Owls (Strix occidentalis caurina) in California. The habitat selection models were estimated, compared, evaluated, and tested using multiple sample datasets collected on federal forestlands in northern California. We used Bayesian methods in interpreting...
USDA-ARS?s Scientific Manuscript database
Malting quality data including diastatic power, ß-amylase activity, and ß-amylase thermostability, were collected on malts from three barley (Hordeum vulgare L.) breeding program trials containing two growth habits and 165 lines grown in multiple environments. We attempted to identify causal polymor...
ERIC Educational Resources Information Center
Zhao, Xiuxi; Lim, Vivien K. G.; Teo, Thompson S. H.
2012-01-01
Applying a multiple-mediator model, we examine the mediating effect of three types of career-specific parenting behaviors: lack of engagement, support, and interference, on the relationship between paternal job insecurity and youths' career self-efficacy. Data were collected from a sample of undergraduate students and their fathers. Results of the…
Indoor air, surface wipes (floors, table tops and window sills) and floor dust samples were collected at multiple locations within 11 occupied and 2 unoccupied homes both prior to and following lawn application of the herbicide 2,4-D. Residue measurements were made over period...
Magnetically encoded luminescent composite nanoparticles through layer-by-layer self-assembly.
Song, Erqun; Han, Weiye; Xu, Hongyan; Jiang, Yunfei; Cheng, Dan; Song, Yang; Swihart, Mark T
2014-11-03
Sensitive and rapid detection of multiple analytes and the collection of components from complex samples are important in fields ranging from bioassays/chemical assays, clinical diagnosis, to environmental monitoring. A convenient strategy for creating magnetically encoded luminescent CdTe@SiO2 @n Fe3 O4 composite nanoparticles, by using a layer-by-layer self-assembly approach based on electrostatic interactions, is described. Silica-coated CdTe quantum dots (CdTe@SiO2 ) serve as core templates for the deposition of alternating layers of Fe3 O4 magnetic nanoparticles and poly(dimethyldiallyl ammonium chloride), to construct CdTe@SiO2 @n Fe3 O4 (n=1, 2, 3, …︁) composite nanoparticles with a defined number (n) of Fe3 O4 layers. Composite nanoparticles were characterized by zeta-potential analysis, fluorescence spectroscopy, vibrating sample magnetometry, and transmission electron microscopy, which showed that the CdTe@SiO2 @n Fe3 O4 composite nanoparticles exhibited excellent luminescence properties coupled with well-defined magnetic responses. To demonstrate the utility of these magnetically encoded nanoparticles for near-simultaneous detection and separation of multiple components from complex samples, three different fluorescently labeled IgG proteins, as model targets, were identified and collected from a mixture by using the CdTe@SiO2 @n Fe3 O4 nanoparticles. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
System for determining position of normal shock in supersonic flow
NASA Technical Reports Server (NTRS)
Iverson, Jr., Donald G. (Inventor); Daiber, Troy D. (Inventor)
1991-01-01
Light from a plurality of light emitting diodes is transmitted through optical cables (12) to a lens system. The lenses (56, 58) expand and collimate the light and project it in a sheet (16) across the supersonic inlet of an aircraft power plant perpendicular to incoming airflow. A normal shock bends a portion of the sheet of light (16). A linear array of a multiplicity of optical fiber ends collects discrete samples of light. The samples are processed and compared to a predetermined profile to determine the shock location.
Determination of multiple mycotoxins levels in poultry feeds from Cameroon.
Abia, Wilfred Angie; Simo, Grace Nella; Warth, Benedikt; Sulyok, Michael; Krska, Rudolf; Tchana, Angele; Moundipa, Paul Fewou
2013-02-01
For the first time in Cameroon, this paper reports on multiple mycotoxins occurrences in poultry feeds. Twenty feed samples collected from different poultry farms were analyzed for 320 fungal metabolites by liquid chromatography electrospray ionization tandem mass spectrometry. Results showed feeds contamination by 68 metabolites including 18 mycotoxins/metabolites currently regulated in the European Union such as fumonisins B1 (FB1), B2, and B3; deoxynevalenol (DON); and beta-zearalenol recovered in all samples. FB1 reported highest FB mean level of 468 (range 16-1930) microg kg(-1). Levels of DON and ZEN were mostly concentrated in feeds from western-highlands conversely for FBs and aflatoxins concentrations in Yaounde. Aflatoxin B1 mean level of 40 microg kg(-1) exceeded the worldwide permitted limit for aflatoxins in feed and generally inversely proportional to weight gain in chicken.
Gas Emissions Acquired during the Aircraft Particle Emission Experiment (APEX) Series
NASA Technical Reports Server (NTRS)
Changlie, Wey; Chowen, Chou Wey
2007-01-01
NASA, in collaboration with other US federal agencies, engine/airframe manufacturers, airlines, and airport authorities, recently sponsored a series of 3 ground-based field investigations to examine the particle and gas emissions from a variety of in-use commercial aircraft. Emissions parameters were measured at multiple engine power settings, ranging from idle to maximum thrust, in samples collected at 3 different down stream locations of the exhaust. Sampling rakes at nominally 1 meter down stream contained multiple probes to facilitate a study of the spatial variation of emissions across the engine exhaust plane. Emission indices measured at 1 m were in good agreement with the engine certification data as well as predictions provided by the engine company. However at low power settings, trace species emissions were observed to be highly dependent on ambient conditions and engine temperature.
Proteomic analysis of formalin-fixed paraffin embedded tissue by MALDI imaging mass spectrometry
Casadonte, Rita; Caprioli, Richard M
2012-01-01
Archived formalin-fixed paraffin-embedded (FFPE) tissue collections represent a valuable informational resource for proteomic studies. Multiple FFPE core biopsies can be assembled in a single block to form tissue microarrays (TMAs). We describe a protocol for analyzing protein in FFPE -TMAs using matrix-assisted laser desorption/ionization (MAL DI) imaging mass spectrometry (IMS). The workflow incorporates an antigen retrieval step following deparaffinization, in situ trypsin digestion, matrix application and then mass spectrometry signal acquisition. The direct analysis of FFPE -TMA tissue using IMS allows direct analysis of multiple tissue samples in a single experiment without extraction and purification of proteins. The advantages of high speed and throughput, easy sample handling and excellent reproducibility make this technology a favorable approach for the proteomic analysis of clinical research cohorts with large sample numbers. For example, TMA analysis of 300 FFPE cores would typically require 6 h of total time through data acquisition, not including data analysis. PMID:22011652
Petrova, I D; Kononova, Iu V; Chausov, E V; Shestopalov, A M; Tishkova, F Kh
2013-01-01
506 Hyalomma anatolicum ticks were collected and assayed in two Crimean-Congo hemorrhagic fever (CCHF) endemic regions of Tajikistan. Antigen and RNA of CCHF virus were detected in 3.4% of tick pools from Rudaki district using ELISA and RT-PCR tests. As of Tursunzade district, viral antigen was identified in 9.0% of samples and viral RNA was identified in 8.1% of samples. The multiple alignment of the obtained nucleotide sequences of CCHF virus genome S-segment 287-nt region (996-1282) and multiple alignment of deduced amino acid sequences of the samples, carried out to compare with CCHF virus strains from the GenBank database, as well as phylogenetic analysis, enabled us to conclude that Asia 1 and Asia 2 genotypes of CCHF virus are circulating in Tajikistan. It is important to note that the genotype Asia 1 virus was detected for the first time in Tajikistan.
Kobayashi, Chigusa; Jung, Jaewoon; Matsunaga, Yasuhiro; Mori, Takaharu; Ando, Tadashi; Tamura, Koichi; Kamiya, Motoshi; Sugita, Yuji
2017-09-30
GENeralized-Ensemble SImulation System (GENESIS) is a software package for molecular dynamics (MD) simulation of biological systems. It is designed to extend limitations in system size and accessible time scale by adopting highly parallelized schemes and enhanced conformational sampling algorithms. In this new version, GENESIS 1.1, new functions and advanced algorithms have been added. The all-atom and coarse-grained potential energy functions used in AMBER and GROMACS packages now become available in addition to CHARMM energy functions. The performance of MD simulations has been greatly improved by further optimization, multiple time-step integration, and hybrid (CPU + GPU) computing. The string method and replica-exchange umbrella sampling with flexible collective variable choice are used for finding the minimum free-energy pathway and obtaining free-energy profiles for conformational changes of a macromolecule. These new features increase the usefulness and power of GENESIS for modeling and simulation in biological research. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Meador, M.R.; McIntyre, J.P.; Pollock, K.H.
2003-01-01
Two-pass backpack electrofishing data collected as part of the U.S. Geological Survey's National Water-Quality Assessment Program were analyzed to assess the efficacy of single-pass backpack electrofishing. A two-capture removal model was used to estimate, within 10 river basins across the United States, proportional fish species richness from one-pass electrofishing and probabilities of detection for individual fish species. Mean estimated species richness from first-pass sampling (ps1) ranged from 80.7% to 100% of estimated total species richness for each river basin, based on at least seven samples per basin. However, ps1 values for individual sites ranged from 40% to 100% of estimated total species richness. Additional species unique to the second pass were collected in 50.3% of the samples. Of these, cyprinids and centrarchids were collected most frequently. Proportional fish species richness estimated for the first pass increased significantly with decreasing stream width for 1 of the 10 river basins. When used to calculate probabilities of detection of individual fish species, the removal model failed 48% of the time because the number of individuals of a species was greater in the second pass than in the first pass. Single-pass backpack electrofishing data alone may make it difficult to determine whether characterized fish community structure data are real or spurious. The two-pass removal model can be used to assess the effectiveness of sampling species richness with a single electrofishing pass. However, the two-pass removal model may have limited utility to determine probabilities of detection of individual species and, thus, limit the ability to assess the effectiveness of single-pass sampling to characterize species relative abundances. Multiple-pass (at least three passes) backpack electrofishing at a large number of sites may not be cost-effective as part of a standardized sampling protocol for large-geographic-scale studies. However, multiple-pass electrofishing at some sites may be necessary to better evaluate the adequacy of single-pass electrofishing and to help make meaningful interpretations of fish community structure.
Collins, Charles R; Neal, Jennifer Watling; Neal, Zachary P
2014-12-01
Collective efficacy is defined as residents' perceived collective capacity to take coordinated and interdependent action on issues that affect their lives. This study explored factors associated with neighborhood collective efficacy among residents. Utilizing a national sample of 4,120 urban households provided by Annie E. Casey Foundation's Making Connection Initiative, we investigated the mediating role of residents' perceptions of bonding social capital (i.e. reciprocity, trust, and shared norms) in the association between civic engagement and collective efficacy. Multiple regression analyses revealed that civic engagement and bonding social capital were both directly related to collective efficacy. Additionally, bonding social capital partially mediated the relationship between civic engagement and collective efficacy. Specifically, residents who reported greater levels of civic engagement also reported higher levels of bonding social capital. In turn, residents who reported higher levels of bonding social capital also reported higher levels of neighborhood collective efficacy. We discuss implications of these findings for researchers and practitioners interested in associations of neighborhood collective efficacy.
Zumeta, Larraitz N; Oriol, Xavier; Telletxea, Saioa; Amutio, Alberto; Basabe, Nekane
2015-01-01
This cross-sectional study analyzes the relationship between collective efficacy and two psychosocial processes involved in collective sport-physical activities. It argues that in-group identification and fusion with the group will affect collective efficacy (CE). A sample of 276 university students answered different scales regarding their participation in collective physical and sport activities. Multiple-mediation analyses showed that shared flow and perceived emotional synchrony mediate the relationship between in-group identification and CE, whereas the relationship between identity fusion and CE was only mediated by perceived emotional synchrony. Results suggest that both psychosocial processes explain the positive effects of in-group identification and identity fusion with the group in collective efficacy. Specifically, the role of perceived emotional synchrony in explaining the positive effects of participation in collective sport-physical activities is underlined. In sum, this study highlights the utility of collective actions and social identities to explain the psychosocial processes related to collective efficacy in physical and sports activities. Finally, practical implications are discussed.
Collective Efficacy in Sports and Physical Activities: Perceived Emotional Synchrony and Shared Flow
Zumeta, Larraitz N.; Oriol, Xavier; Telletxea, Saioa; Amutio, Alberto; Basabe, Nekane
2016-01-01
This cross-sectional study analyzes the relationship between collective efficacy and two psychosocial processes involved in collective sport-physical activities. It argues that in-group identification and fusion with the group will affect collective efficacy (CE). A sample of 276 university students answered different scales regarding their participation in collective physical and sport activities. Multiple-mediation analyses showed that shared flow and perceived emotional synchrony mediate the relationship between in-group identification and CE, whereas the relationship between identity fusion and CE was only mediated by perceived emotional synchrony. Results suggest that both psychosocial processes explain the positive effects of in-group identification and identity fusion with the group in collective efficacy. Specifically, the role of perceived emotional synchrony in explaining the positive effects of participation in collective sport-physical activities is underlined. In sum, this study highlights the utility of collective actions and social identities to explain the psychosocial processes related to collective efficacy in physical and sports activities. Finally, practical implications are discussed. PMID:26779077
NEON Data Products: Supporting the Validation of GCOS Essential Climate Variables
NASA Astrophysics Data System (ADS)
Petroy, S. B.; Fox, A. M.; Metzger, S.; Thorpe, A.; Meier, C. L.
2014-12-01
The National Ecological Observatory Network (NEON) is a continental-scale ecological observation platform designed to collect and disseminate data that contributes to understanding and forecasting the impacts of climate change, land use change, and invasive species on ecology. NEON will collect in-situ and airborne data over 60 sites across the US, including Alaska, Hawaii, and Puerto Rico. The NEON Biomass, Productivity, and Biogeochemistry protocols currently direct the collection of samples from distributed, gradient, and tower plots at each site, with sampling occurring either multiple times during the growing season, annually, or on three- or five-year centers (e.g. for coarse woody debris). These data are processed into a series of field-derived data products (e.g. Biogeochemistry, LAI, above ground Biomass, etc.), and when combined with the NEON airborne hyperspectral and LiDAR imagery, are used support validation efforts of algorithms for deriving vegetation characteristics from the airborne data. Sites are further characterized using airborne data combined with in-situ tower measurements, to create additional data products of interest to the GCOS community, such as Albedo and fPAR. Presented here are a summary of tower/field/airborne sampling and observation protocols and examples of provisional datasets collected at NEON sites that may be used to support the ongoing validation of GCOS Essential Climate Variables.
Fong, Erika J.; Huang, Chao; Hamilton, Julie; ...
2015-11-23
Here, a major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection,more » system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.« less
Modular "plug-and-play" capsules for multi-capsule environment in the gastrointestinal tract.
Phee, S J; Ting, E K; Lin, L; Huynh, V A; Kencana, A P; Wong, K J; Tan, S L
2009-01-01
The invention of wireless capsule endoscopy has opened new ways of diagnosing and treating diseases in the gastrointestinal tract. Current wireless capsules can perform simple operations such as imaging and data collection (like temperature, pressure, and pH) in the gastrointestinal tract. Researchers are now focusing on adding more sophisticated functions such as drug delivery, surgical clips/tags deployment, and tissue samples collection. The finite on-board power on these capsules is one of the factors that limits the functionalities of these wireless capsules. Thus multiple application-specific capsules would be needed to complete an endoscopic operation. This would give rise to a multi-capsule environment. Having a modular "plug-and-play" capsule design would facilitate doctors in configuring multiple application-specific capsules, e.g. tagging capsule, for use in the gastrointestinal tract. This multi-capsule environment also has the advantage of reducing power consumption through asymmetric multi-hop communication.
Chamings, Anthony; Nelson, Tiffanie M; Vibin, Jessy; Wille, Michelle; Klaassen, Marcel; Alexandersen, Soren
2018-04-13
We evaluated the presence of coronaviruses by PCR in 918 Australian wild bird samples collected during 2016-17. Coronaviruses were detected in 141 samples (15.3%) from species of ducks, shorebirds and herons and from multiple sampling locations. Sequencing of selected positive samples found mainly gammacoronaviruses, but also some deltacoronaviruses. The detection rate of coronaviruses was improved by using multiple PCR assays, as no single assay could detect all coronavirus positive samples. Sequencing of the relatively conserved Orf1 PCR amplicons found that Australian duck gammacoronaviruses were similar to duck gammacoronaviruses around the world. Some sequenced shorebird gammacoronaviruses belonged to Charadriiformes lineages, but others were more closely related to duck gammacoronaviruses. Australian duck and heron deltacoronaviruses belonged to lineages with other duck and heron deltacoronaviruses, but were almost 20% different in nucleotide sequence to other deltacoronavirus sequences available. Deltacoronavirus sequences from shorebirds formed a lineage with a deltacoronavirus from a ruddy turnstone detected in the United States. Given that Australian duck gammacoronaviruses are highly similar to those found in other regions, and Australian ducks rarely come into contact with migratory Palearctic duck species, we hypothesise that migratory shorebirds are the important vector for moving wild bird coronaviruses into and out of Australia.
RESPONDENT-DRIVEN SAMPLING AS MARKOV CHAIN MONTE CARLO
GOEL, SHARAD; SALGANIK, MATTHEW J.
2013-01-01
Respondent-driven sampling (RDS) is a recently introduced, and now widely used, technique for estimating disease prevalence in hidden populations. RDS data are collected through a snowball mechanism, in which current sample members recruit future sample members. In this paper we present respondent-driven sampling as Markov chain Monte Carlo (MCMC) importance sampling, and we examine the effects of community structure and the recruitment procedure on the variance of RDS estimates. Past work has assumed that the variance of RDS estimates is primarily affected by segregation between healthy and infected individuals. We examine an illustrative model to show that this is not necessarily the case, and that bottlenecks anywhere in the networks can substantially affect estimates. We also show that variance is inflated by a common design feature in which sample members are encouraged to recruit multiple future sample members. The paper concludes with suggestions for implementing and evaluating respondent-driven sampling studies. PMID:19572381
Hower, Suzanne; Phillips, Matthew C; Brodsky, Micah; Dameron, Adrienne; Tamargo, Manuel A; Salazar, Norma C; Jackson, Charlene R; Barrett, John B; Davidson, Maureen; Davis, Johnnie; Mukherjee, Sampa; Ewing, Ruth Y; Gidley, Maribeth L; Sinigalliano, Christopher D; Johns, Lisa; Johnson, Frank E; Adebanjo, Olufunmilola; Plano, Lisa R W
2013-05-01
In May of 2011, a live mass stranding of 26 short-finned pilot whales (Globicephala macrorhynchus) occurred in the lower Florida Keys. Five surviving whales were transferred from the original stranding site to a nearby marine mammal rehabilitation facility where they were constantly attended to by a team of volunteers. Bacteria cultured during the routine clinical care of the whales and necropsy of a deceased whale included methicillin-sensitive and methicillin-resistant Staphylococcus aureus (MSSA and MRSA). In order to investigate potential sources or reservoirs of MSSA and MRSA, samples were obtained from human volunteers, whales, seawater, and sand from multiple sites at the facility, nearby recreational beaches, and a canal. Samples were collected on 3 days. The second collection day was 2 weeks after the first, and the third collection day was 2 months after the last animal was removed from the facility. MRSA and MSSA were isolated on each day from the facility when animals and volunteers were present. MSSA was found at an adjacent beach on all three collection days. Isolates were characterized by utilizing a combination of quantitative real-time PCR to determine the presence of mecA and genes associated with virulence, staphylococcal protein A typing, staphylococcal cassette chromosome mec typing, multilocus sequence typing, and pulsed field gel electrophoresis (PFGE). Using these methods, clonally related MRSA were isolated from multiple environmental locations as well as from humans and animals. Non-identical but genetically similar MSSA and MRSA were also identified from distinct sources within this sample pool. PFGE indicated that the majority of MRSA isolates were clonally related to the prototype human strain USA300. These studies support the notion that S. aureus may be shed into an environment by humans or pilot whales and subsequently colonize or infect exposed new hosts.
da Cunha Santos, Gilda; Liu, Ni; Tsao, Ming-Sound; Kamel-Reid, Suzanne; Chin, Kayu; Geddie, William R
2010-12-25
The aims of this study were to compare the quality of DNA recovered from fine-needle aspirates (FNAs) stored on Whatman FTA cards with that retrieved from corresponding cell blocks and to determine whether the DNA extracted from the cards is suitable for multiple mutation analyses. FNAs collected from 18 resected lung tumors and cell suspensions from 4 lung cancer cell lines were placed on FTA Indicating Micro Cards and further processed to produce paired formalin-fixed paraffin-embedded (FFPE) cell blocks. Fragment analysis was used for the detection of EGFR exon 19 deletion, and direct sequencing for detection of EGFR exon 21 L858R mutation and exon 2 deletion of KRAS. Corresponding FFPE tissue sections from 2 resection specimens were also tested. Analyses were successful with all FNAs and lung cancer-derived cell lines collected on cards. Polymerase chain reaction failed in 2 cell blocks. For FNAs collected on cards, 5 cases showed EGFR and 3 showed KRAS mutations. Eleven cases were wild type. With cell blocks, 4 cases were found to harbor KRAS and 4 harbored EGFR mutations. All lung cancer-derived cell lines tested positive for their respective mutations, and there was complete agreement between card and cell block FNA samples for EGFR exon 21. For EGFR exon 19, 1 of 18 cases showed discordant results between the card and cell block, and for KRAS 1 of 17. The two resection specimens tested gave concordant results with the FTA card. Storage of cytologic material on FTA cards can maximize and simplify sample procurement for multiple mutational analyses with results similar to those from cell blocks.
Fulton, Robert W.; Whitley, Evan M.; Johnson, Bill J.; Ridpath, Julia F.; Kapil, Sanjay; Burge, Lurinda J.; Cook, Billy J.; Confer, Anthony W.
2009-01-01
The prevalence of bovine viral diarrhea virus (BVDV) in persistently infected (PI) cattle in beef breeding herds was determined using 30 herds with 4530 calves. The samples were collected by ear notches and tested for BVDV antigens using immunohistochemistry (IHC) and antigen capture enzyme-linked immunosorbent assay (ACE). Animals with initial positives on both IHC and ACE were sampled again using both tests and serums were collected for viral propagation and sequencing of a viral genomic region, 5′-untranslated region (5′-UTR) for viral subtyping. Samples were also collected from the dams of PI calves. There were 25 PI calves from 4530 samples (0.55%) and these PI calves were from 5 of the 30 herds (16.7%). Two herds had multiple PI calves and 3 herds had only 1 PI calf. Only 1 of the 25 dams with a PI calf was also PI (4.0%). The subtype of all the PI isolates was BVDV1b. Histories of the ranches indicated 23 out of 30 had herd additions of untested breeding females. Twenty-four of the 30 herds had adult cowherd vaccinations against BVDV, primarily using killed BVDV vaccines at pregnancy examination. PMID:20046630
McCobb, Timothy D.; LeBlanc, Denis R.
2011-01-01
The U.S. Geological Survey (USGS) collected water-quality data between 2001 and 2010 in the Fishermans Cove area of Ashumet Pond, Falmouth, Massachusetts, where the eastern portion of a treated-wastewater plume, created by more than 60 years of overland disposal, discharges to the pond. Temporary drive points were installed, and shallow pond-bottom groundwater was sampled, at 167 locations in 2001, 150 locations in 2003, and 120 locations in 2004 to delineate the distribution of wastewater-related constituents. In 2004, the Air Force Center for Engineering and the Environment (AFCEE) installed a pond-bottom permeable reactive barrier (PRB) to intercept phosphate in the plume at its discharge point to the pond. The USGS monitored the performance of the PRB by collecting samples from temporary drive points at multiple depth intervals in 2006 (200 samples at 76 locations) and 2009 (150 samples at 90 locations). During the first 5 years after installation of the PRB, water samples were collected periodically from five types of pore-water samplers that had been permanently installed in and near the PRB during the barrier's emplacement. The distribution of wastewater-related constituents in the pond-bottom groundwater and changes in the geochemistry of the pond-bottom groundwater after installation of the PRB have been documented in several published reports that are listed in the references.
Han, Jiarui; Zhang, Xiangru; Liu, Jiaqi; Zhu, Xiaohu; Gong, Tingting
2017-08-01
Chlorine dioxide (ClO 2 ) is a widely used alternative disinfectant due to its high biocidal efficiency and low-level formation of trihalomethanes and haloacetic acids. A major portion of total organic halogen (TOX), a collective parameter for all halogenated DBPs, formed in ClO 2 -treated drinking water is still unknown. A commonly used pretreatment method for analyzing halogenated DBPs in drinking water is one-time liquid-liquid extraction (LLE), which may lead to a substantial loss of DBPs prior to analysis. In this study, characterization and identification of polar halogenated DBPs in a ClO 2 -treated drinking water sample were conducted by pretreating the sample with multiple extractions. Compared to one-time LLE, the combined four-time LLEs improved the recovery of TOX by 2.3 times. The developmental toxicity of the drinking water sample pretreated with the combined four-time LLEs was 1.67 times higher than that pretreated with one-time LLE. With the aid of ultra-performance liquid chromatography/electrospray ionization-triple quadrupole mass spectrometry, a new group of polar halogenated DBPs, trihalomethanols, were detected in the drinking water sample pretreated with multiple extractions; two of them, trichloromethanol and bromodichloromethanol, were identified with synthesized standard compounds. Moreover, these trihalomethanols were found to be the transformation products of trihalomethanes formed during ClO 2 disinfection. The results indicate that multiple LLEs can significantly improve extraction efficiencies of polar halogenated DBPs and is a better pretreatment method for characterizing and identifying new polar halogenated DBPs in drinking water. Copyright © 2017. Published by Elsevier B.V.
Tutterrow, Yeung L.; Avril, Marion; Singh, Kavita; Long, Carole A.; Leke, Robert J.; Sama, Grace; Salanti, Ali; Smith, Joseph D.; Leke, Rose G. F.
2012-01-01
Placental malaria, caused by sequestration of Plasmodium falciparum-infected erythrocytes in the placenta, is associated with increased risk of maternal morbidity and poor birth outcomes. The parasite antigen VAR2CSA (variant surface antigen 2-chondroitin sulfate A) is expressed on infected erythrocytes and mediates binding to chondroitin sulfate A, initiating inflammation and disrupting homeostasis at the maternal-fetal interface. Although antibodies can prevent sequestration, it is unclear whether parasite clearance is due to antibodies to a single Duffy binding-like (DBL) domain or to an extensive repertoire of antibodies to multiple DBL domains and allelic variants. Accordingly, plasma samples collected longitudinally from pregnant women were screened for naturally acquired antibodies against an extensive panel of VAR2CSA proteins, including 2 to 3 allelic variants for each of 5 different DBL domains. Analyses were performed on plasma samples collected from 3 to 9 months of pregnancy from women living in areas in Cameroon with high and low malaria transmission. The results demonstrate that high antibody levels to multiple VAR2CSA domains, rather than a single domain, were associated with the absence of placental malaria when antibodies were present from early in the second trimester until term. Absence of placental malaria was associated with increasing antibody breadth to different DBL domains and allelic variants in multigravid women. Furthermore, the antibody responses of women in the lower-transmission site had both lower magnitude and lesser breadth than those in the high-transmission site. These data suggest that immunity to placental malaria results from high antibody levels to multiple VAR2CSA domains and allelic variants and that antibody breadth is influenced by malaria transmission intensity. PMID:22331427
Zuo, Chandler; Chen, Kailei; Keleş, Sündüz
2017-06-01
Current analytic approaches for querying large collections of chromatin immunoprecipitation followed by sequencing (ChIP-seq) data from multiple cell types rely on individual analysis of each data set (i.e., peak calling) independently. This approach discards the fact that functional elements are frequently shared among related cell types and leads to overestimation of the extent of divergence between different ChIP-seq samples. Methods geared toward multisample investigations have limited applicability in settings that aim to integrate 100s to 1000s of ChIP-seq data sets for query loci (e.g., thousands of genomic loci with a specific binding site). Recently, Zuo et al. developed a hierarchical framework for state-space matrix inference and clustering, named MBASIC, to enable joint analysis of user-specified loci across multiple ChIP-seq data sets. Although this versatile framework estimates both the underlying state-space (e.g., bound vs. unbound) and also groups loci with similar patterns together, its Expectation-Maximization-based estimation structure hinders its applicability with large number of loci and samples. We address this limitation by developing MAP-based asymptotic derivations from Bayes (MAD-Bayes) framework for MBASIC. This results in a K-means-like optimization algorithm that converges rapidly and hence enables exploring multiple initialization schemes and flexibility in tuning. Comparison with MBASIC indicates that this speed comes at a relatively insignificant loss in estimation accuracy. Although MAD-Bayes MBASIC is specifically designed for the analysis of user-specified loci, it is able to capture overall patterns of histone marks from multiple ChIP-seq data sets similar to those identified by genome-wide segmentation methods such as ChromHMM and Spectacle.
Tong, Louis; Zhou, Xi Yuan; Jylha, Antti; Aapola, Ulla; Liu, Dan Ning; Koh, Siew Kwan; Tian, Dechao; Quah, Joanne; Uusitalo, Hannu; Beuerman, Roger W; Zhou, Lei
2015-02-06
Tear proteins are intimately related to the pathophysiology of the ocular surface. Many recent studies have demonstrated that the tear is an accessible fluid for studying eye diseases and biomarker discovery. This study describes a high resolution multiple reaction monitoring (HR-MRM) approach for developing assays for quantification of biologically important tear proteins. Human tear samples were collected from 1000 subjects with no eye complaints (411 male, 589 female, average age: 55.5±14.5years) after obtaining informed consent. Tear samples were collected using Schirmer's strips and pooled into a single global control sample. Quantification of proteins was carried out by selecting "signature" peptides derived by trypsin digestion. A 1-h nanoLC-MS/MS run was used to quantify the tear proteins in HR-MRM mode. Good reproducibility of signal intensity (using peak areas) was demonstrated for all 47 HR-MRM assays with an average coefficient of variation (CV%) of 4.82% (range: 1.52-10.30%). All assays showed consistent retention time with a CV of less than 0.80% (average: 0.57%). HR-MRM absolute quantitation of eight tear proteins was demonstrated using stable isotope-labeled peptides. In this study, we demonstrated for the first time the technique to quantify 47 human tear proteins in HR-MRM mode using approximately 1μl of human tear sample. These multiplexed HR-MRM-based assays show great promise of further development for biomarker validation in human tear samples. Both discovery-based and targeted quantitative proteomics can be achieved in a single quadrupole time-of-flight mass spectrometer platform (TripleTOF 5600 system). Copyright © 2015 Elsevier B.V. All rights reserved.
Generation Scotland: Donor DNA Databank; A control DNA resource.
Kerr, Shona M; Liewald, David C M; Campbell, Archie; Taylor, Kerrie; Wild, Sarah H; Newby, David; Turner, Marc; Porteous, David J
2010-11-23
Many medical disorders of public health importance are complex diseases caused by multiple genetic, environmental and lifestyle factors. Recent technological advances have made it possible to analyse the genetic variants that predispose to complex diseases. Reliable detection of these variants requires genome-wide association studies in sufficiently large numbers of cases and controls. This approach is often hampered by difficulties in collecting appropriate control samples. The Generation Scotland: Donor DNA Databank (GS:3D) aims to help solve this problem by providing a resource of control DNA and plasma samples accessible for research. GS:3D participants were recruited from volunteer blood donors attending Scottish National Blood Transfusion Service (SNBTS) clinics across Scotland. All participants gave full written consent for GS:3D to take spare blood from their normal donation. Participants also supplied demographic data by completing a short questionnaire. Over five thousand complete sets of samples, data and consent forms were collected. DNA and plasma were extracted and stored. The data and samples were unlinked from their original SNBTS identifier number. The plasma, DNA and demographic data are available for research. New data obtained from analysis of the resource will be fed back to GS:3D and will be made available to other researchers as appropriate. Recruitment of blood donors is an efficient and cost-effective way of collecting thousands of control samples. Because the collection is large, subsets of controls can be selected, based on age range, gender, and ethnic or geographic origin. The GS:3D resource should reduce time and expense for investigators who would otherwise have had to recruit their own controls.
Feasibility of conducting wetfall chemistry investigations around the Bowen Power Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, N.C.J.; Patrinos, A.A.N.
1979-10-01
The feasibility of expanding the Meteorological Effects of Thermal Energy Releases - Oak Ridge National Laboratory (METER-ORNL) research at Bower Power Plant, a coal-fired power plant in northwest Georgia, to include wetfall chemistry is evaluated using results of similar studies around other power plants, several atmospheric washout models, analysis of spatial variability in precipitation, and field logistical considerations. An optimal wetfall chemistry network design is proposed, incorporating the inner portion of the existing rain-gauge network and augmented by additional sites to ensure adequate coverage of probable target areas. The predicted sulfate production rate differs by about four orders of magnitudemore » among the models reviewed with a pH of 3. No model can claim superiority over any other model without substantive data verification. The spatial uniformity in rain amount is evaluated using four storms that occurred at the METER-ORNL network. Values of spatial variability ranged from 8 to 31% and decreased as the mean rainfall increased. The field study of wetfall chemistry will require a minimum of 5 persons to operate the approximately 50 collectors covering an area of 740 km/sup 2/. Preliminary wetfall-only samples collected on an event basis showed lower pH and higher electrical conductivity of precipitation collected about 5 km downwind of the power plant relative to samples collected upwind. Wetfall samples collected on a weekly basis using automatic samplers, however, showed variable results, with no consistent pattern. This suggests the need for event sampling to minimize variable rain volume and multiple-source effects often associated with weekly samples.« less
Variance partitioning of stream diatom, fish, and invertebrate indicators of biological condition
Zuellig, Robert E.; Carlisle, Daren M.; Meador, Michael R.; Potapova, Marina
2012-01-01
Stream indicators used to make assessments of biological condition are influenced by many possible sources of variability. To examine this issue, we used multiple-year and multiple-reach diatom, fish, and invertebrate data collected from 20 least-disturbed and 46 developed stream segments between 1993 and 2004 as part of the US Geological Survey National Water Quality Assessment Program. We used a variance-component model to summarize the relative and absolute magnitude of 4 variance components (among-site, among-year, site × year interaction, and residual) in indicator values (observed/expected ratio [O/E] and regional multimetric indices [MMI]) among assemblages and between basin types (least-disturbed and developed). We used multiple-reach samples to evaluate discordance in site assessments of biological condition caused by sampling variability. Overall, patterns in variance partitioning were similar among assemblages and basin types with one exception. Among-site variance dominated the relative contribution to the total variance (64–80% of total variance), residual variance (sampling variance) accounted for more variability (8–26%) than interaction variance (5–12%), and among-year variance was always negligible (0–0.2%). The exception to this general pattern was for invertebrates at least-disturbed sites where variability in O/E indicators was partitioned between among-site and residual (sampling) variance (among-site = 36%, residual = 64%). This pattern was not observed for fish and diatom indicators (O/E and regional MMI). We suspect that unexplained sampling variability is what largely remained after the invertebrate indicators (O/E predictive models) had accounted for environmental differences among least-disturbed sites. The influence of sampling variability on discordance of within-site assessments was assemblage or basin-type specific. Discordance among assessments was nearly 2× greater in developed basins (29–31%) than in least-disturbed sites (15–16%) for invertebrates and diatoms, whereas discordance among assessments based on fish did not differ between basin types (least-disturbed = 16%, developed = 17%). Assessments made using invertebrate and diatom indicators from a single reach disagreed with other samples collected within the same stream segment nearly ⅓ of the time in developed basins, compared to ⅙ for all other cases.
Schousboe, Mette L.; Ranjitkar, Samir; Rajakaruna, Rupika S.; Amerasinghe, Priyanie H.; Morales, Francisco; Pearce, Richard; Ord, Rosalyn; Leslie, Toby; Rowland, Mark; Gadalla, Nahla B.; Konradsen, Flemming; Bygbjerg, Ib C.; Roper, Cally; Alifrangis, Michael
2015-01-01
Background Chloroquine combined with primaquine has been the recommended antimalarial treatment of Plasmodium vivax malaria infections for six decades but the efficacy of this treatment regimen is threatened by chloroquine resistance (CQR). Single nucleotide polymorphisms (SNPs) in the multidrug resistance gene, Pvmdr1 are putative determinants of CQR but the extent of their emergence at population level remains to be explored. Objective In this study we describe the prevalence of SNPs in the Pvmdr1 among samples collected in seven P. vivax endemic countries and we looked for molecular evidence of drug selection by characterising polymorphism at microsatellite (MS) loci flanking the Pvmdr1 gene. Methods We examined the prevalence of SNPs in the Pvmdr1 gene among 267 samples collected from Pakistan, Afghanistan, Sri Lanka, Nepal, Sudan, São Tomé and Ecuador. We measured and diversity in four microsatellite (MS) markers flanking the Pvmdr1 gene to look evidence of selection on mutant alleles. Results SNP polymorphism in the Pvmdr1 gene was largely confined to codons T958M, Y976F and F1076L. Only 2.4% of samples were wildtype at all three codons (TYF, n = 5), 13.3% (n = 28) of the samples were single mutant MYF, 63.0% of samples (n = 133) were double mutant MYL, and 21.3% (n = 45) were triple mutant MFL. Clear geographic differences in the prevalence of these Pvmdr mutation combinations were observed. Significant linkage disequilibrium (LD) between Pvmdr1 and MS alleles was found in populations sampled in Ecuador, Nepal and Sri Lanka, while significant LD between Pvmdr1 and the combined 4 MS locus haplotype was only seen in Ecuador and Sri Lanka. When combining the 5 loci, high level diversity, measured as expected heterozygosity (He), was seen in the complete sample set (He = 0.99), while He estimates for individual loci ranged from 0.00–0.93. Although Pvmdr1 haplotypes were not consistently associated with specific flanking MS alleles, there was significant differentiation between geographic sites which could indicate directional selection through local drug pressure. Conclusions Our observations suggest that Pvmdr1 mutations emerged independently on multiple occasions even within the same population. In Sri Lanka population analysis at multiple sites showed evidence of local selection and geographical dispersal of Pvmdr1 mutations between sites. PMID:26539821
Nuts and Bolts - Techniques for Genesis Sample Curation
NASA Technical Reports Server (NTRS)
Burkett, Patti J.; Rodriquez, M. C.; Allton, J. H.
2011-01-01
The Genesis curation staff at NASA Johnson Space Center provides samples and data for analysis to the scientific community, following allocation approval by the Genesis Oversight Committee, a sub-committee of CAPTEM (Curation Analysis Planning Team for Extraterrestrial Materials). We are often asked by investigators within the scientific community how we choose samples to best fit the requirements of the request. Here we will demonstrate our techniques for characterizing samples and satisfying allocation requests. Even with a systematic approach, every allocation is unique. We are also providing updated status of the cataloging and characterization of solar wind collectors as of January 2011. The collection consists of 3721 inventoried samples consisting of a single fragment, or multiple fragments containerized or pressed between post-it notes, jars or vials of various sizes.
Skinner, Kenneth D.
2018-05-11
Groundwater-quality samples and water-level data were collected from 36 wells in the Jerome/Gooding County area of the eastern Snake River Plain aquifer during June 2017. The wells included 30 wells sampled for the U.S. Geological Survey’s National Water-Quality Assessment project, plus an additional 6 wells were selected to increase spatial distribution. The data provide water managers with the ability for an improved understanding of groundwater quality and flow directions in the area. Groundwater-quality samples were analyzed for nutrients, major ions, trace elements, and stable isotopes of water. Quality-assurance and quality-control measures consisted of multiple blank samples and a sequential replicate sample. All data are available online at the USGS National Water Information System.
Aylward, Lesa L; Hays, Sean M; Zidek, Angelika
2017-01-01
Population biomonitoring data sets such as the Canadian Health Measures Survey (CHMS) and the United States National Health and Nutrition Examination Survey (NHANES) collect and analyze spot urine samples for analysis for biomarkers of exposure to non-persistent chemicals. Estimation of population intakes using such data sets in a risk-assessment context requires consideration of intra- and inter-individual variability to understand the relationship between variation in the biomarker concentrations and variation in the underlying daily and longer-term intakes. Two intensive data sets with a total of 16 individuals with collection and measurement of serial urine voids over multiple days were used to examine these relationships using methyl paraben, triclosan, bisphenol A (BPA), monoethyl phthalate (MEP), and mono-2-ethylhexyl hydroxyl phthalate (MEHHP) as example compounds. Composited 24 h voids were constructed mathematically from the individual collected voids, and concentrations for each 24 h period and average multiday concentrations were calculated for each individual in the data sets. Geometric mean and 95th percentiles were compared to assess the relationship between distributions in spot sample concentrations and the 24 h and multiday collection averages. In these data sets, spot sample concentrations at the 95th percentile were similar to or slightly higher than the 95th percentile of the distribution of all 24 h composite void concentrations, but tended to overestimate the maximum of the multiday concentration averages for most analytes (usually by less than a factor of 2). These observations can assist in the interpretation of population distributions of spot samples for frequently detected analytes with relatively short elimination half-lives. PMID:27703149
Seagrave, JeanClare; McDonald, Jacob D; Gigliotti, Andrew P; Nikula, Kristen J; Seilkop, Steven K; Gurevich, Michael; Mauderly, Joe L
2002-12-01
Exposure to engine emissions is associated with adverse health effects. However, little is known about the relative effects of emissions produced by different operating conditions, fuels, or technologies. Rapid screening techniques are needed to compare the biological effects of emissions with different characteristics. Here, we examined a set of engine emission samples using conventional bioassays. The samples included combined particulate material and semivolatile organic compound fractions of emissions collected from normal- and high-emitter gasoline and diesel vehicles collected at 72 degrees F, and from normal-emitter groups collected at 30 degrees F. The relative potency of the samples was determined by statistical analysis of the dose-response curves. All samples induced bacterial mutagenicity, with a 10-fold range of potency among the samples. Responses to intratracheal instillation in rats indicated generally parallel rankings of the samples by multiple endpoints reflecting cytotoxic, inflammatory, and lung parenchymal changes, allowing selection of a more limited set of parameters for future studies. The parameters selected to assess oxidative stress and macrophage function yielded little useful information. Responses to instillation indicated little difference in potency per unit of combined particulate material and semivolatile organic compound mass between normal-emitter gasoline and diesel vehicles, or between emissions collected at different temperatures. However, equivalent masses of emissions from high-emitter vehicles of both types were more potent than those from normal-emitters. While preliminary in terms of assessing contributions of different emissions to health hazards, the results indicate that a subset of this panel of assays will be useful in providing rapid, cost-effective feedback on the biological impact of modified technology.
New measurements of particulates in glacial snow and ice in the Cordillera Blanca mountains of Peru
NASA Astrophysics Data System (ADS)
All, J.; Schmitt, C.; Celestian, A. J.; Rucks, M.; Arnott, W. P.; Cole, R.
2012-12-01
During the local dry season (June/July) of 2011 and 2012, the American Climber Science Program (organized with the assistance of the American Alpine Club) conducted scientific expeditions in Huascaran National Park in Peru. The Park is located in the Cordillera Blanca mountain range and contains the world's largest collection of tropical mountain glaciers. One component of the environmental research program was sampling particulates on glacier surfaces by means of snow collection and filtration. Over 150 samples were collected during the two expeditions by volunteer climbers working with scientists in the field. Glacier snows were collected on over fifteen peaks throughout the range at altitudes from 4800 to nearly 6800 meters. Snow samples were kept frozen until the climber-scientists returned to basecamp - at which point they were rapidly melted and then immediately filtered through 0.7 micron PallFlex tissuequartz filters. The particulates captured on the filters have been analyzed for their bulk heat absorption properties as well as to determine the properties of individual particles through X-ray diffraction for bulk mineral identification, and Raman microscopy for chemical mapping of minerals. Preliminary results indicate that snow age, altitude, as well as geographic location (with respect to urban areas, mines, and predominant wind direction) all play significant roles in the amount and types of contaminants. Multiple locations were sampled during both expeditions as well as at different times during the same climbing season. Results include the relative heating capacity of the samples at various wavelengths as well as mineral composition information across the range. Local weather patterns and geographic observations will be used to identify potential sources of contaminants. Sampling will continue under the American Climber Science Program in 2013 and beyond.
Characterization of Friction Joints Subjected to High Levels of Random Vibration
NASA Technical Reports Server (NTRS)
deSantos, Omar; MacNeal, Paul
2012-01-01
This paper describes the test program in detail including test sample description, test procedures, and vibration test results of multiple test samples. The material pairs used in the experiment were Aluminum-Aluminum, Aluminum- Dicronite coated Aluminum, and Aluminum-Plasmadize coated Aluminum. Levels of vibration for each set of twelve samples of each material pairing were gradually increased until all samples experienced substantial displacement. Data was collected on 1) acceleration in all three axes, 2) relative static displacement between vibration runs utilizing photogrammetry techniques, and 3) surface galling and contaminant generation. This data was used to estimate the values of static friction during random vibratory motion when "stick-slip" occurs and compare these to static friction coefficients measured before and after vibration testing.
Citizen science contributes to our knowledge of invasive plant species distributions
Crall, Alycia W.; Jarnevich, Catherine S.; Young, Nicholas E.; Panke, Brendon; Renz, Mark; Stohlgren, Thomas
2015-01-01
Citizen science is commonly cited as an effective approach to expand the scale of invasive species data collection and monitoring. However, researchers often hesitate to use these data due to concerns over data quality. In light of recent research on the quality of data collected by volunteers, we aimed to demonstrate the extent to which citizen science data can increase sampling coverage, fill gaps in species distributions, and improve habitat suitability models compared to professionally generated data sets used in isolation. We combined data sets from professionals and volunteers for five invasive plant species (Alliaria petiolata, Berberis thunbergii, Cirsium palustre, Pastinaca sativa, Polygonum cuspidatum) in portions of Wisconsin. Volunteers sampled counties not sampled by professionals for three of the five species. Volunteers also added presence locations within counties not included in professional data sets, especially in southern portions of the state where professional monitoring activities had been minimal. Volunteers made a significant contribution to the known distribution, environmental gradients sampled, and the habitat suitability of P. cuspidatum. Models generated with professional data sets for the other four species performed reasonably well according to AUC values (>0.76). The addition of volunteer data did not greatly change model performance (AUC > 0.79) but did change the suitability surface generated by the models, making them more realistic. Our findings underscore the need to merge data from multiple sources to improve knowledge of current species distributions, and to predict their movement under present and future environmental conditions. The efficiency and success of these approaches require that monitoring efforts involve multiple stakeholders in continuous collaboration via established monitoring networks.
Kumar, Deepak; Pornsukarom, Suchawan; Sivaraman, G K; Thakur, Siddhartha
2018-04-01
The deposition of manure originating from food animal farms in the environment can lead to the dissemination of antimicrobial-resistant (AMR) bacterial foodborne pathogens, thereby potentially impacting human health. The objective of our study was to determine the dissemination of multidrug methicillin-resistant Staphylococcus sciuri (MDR-MRSS) in the environment after land application of manure on commercial swine farms. A total of 400 environmental samples (40 manure and 360 soil) were collected after repeated sampling from four commercial swine farms located in North Carolina (n = 1) and Iowa (n = 3) in the United States. At each farm, we collected 10 manure and 40 soil samples (20 samples before and after 2 h of manure application) from four plots (five soil samples/plot) on day 0. Subsequently, 20 soil samples were collected on day 7, 14, and 21 from the same plots. A total of 67 (16.75%) MRSS were isolated from the 400 samples. The prevalence in soil and manure was 13.33% (48/360) and 47.5% (19/40), respectively. Prevalence was highest in the soil samples collected after 2 h of manure application on day 0 and decreased subsequently on 7, 14, and 21 days. Antimicrobial susceptibility testing was done against a panel of 12 antibiotics. A majority of S. sciuri isolates exhibited resistance against ampicillin (AMP; 95.5%), penicillin (PEN; 95.5%), clindamycin (CLI; 95.5%), cefoxitin (FOX; 92.5%), ceftiofur (XNL; 92.5%), tetracycline (TET; 86.56%), and erythromycin (ERY; 50.74%). The MDR pattern AMP FOX CLI PEN TET XNL (n = 24; 35.8%) was the most commonly observed. We detected multiple AMR genes, including mecA, aac(6'), Ie-aph(2″)Ia, tetM, tetK, mphC, ermA, ermB, and ermC. Pulsed-field gel electrophoresis clustered isolates from different sample collection days from the same farm into one group. Overall, our study identifies swine manure as an important reservoir of MDR-MRSS and highlights its dissemination in the environment upon spreading of manure.
History and evaluation of national-scale geochemical data sets for the United States
Smith, David B.; Smith, Steven M.; Horton, John D.
2013-01-01
Six national-scale, or near national-scale, geochemical data sets for soils or stream sediments exist for the United States. The earliest of these, here termed the ‘Shacklette’ data set, was generated by a U.S. Geological Survey (USGS) project conducted from 1961 to 1975. This project used soil collected from a depth of about 20 cm as the sampling medium at 1323 sites throughout the conterminous U.S. The National Uranium Resource Evaluation Hydrogeochemical and Stream Sediment Reconnaissance (NURE-HSSR) Program of the U.S. Department of Energy was conducted from 1975 to 1984 and collected either stream sediments, lake sediments, or soils at more than 378,000 sites in both the conterminous U.S. and Alaska. The sampled area represented about 65% of the nation. The Natural Resources Conservation Service (NRCS), from 1978 to 1982, collected samples from multiple soil horizons at sites within the major crop-growing regions of the conterminous U.S. This data set contains analyses of more than 3000 samples. The National Geochemical Survey, a USGS project conducted from 1997 to 2009, used a subset of the NURE-HSSR archival samples as its starting point and then collected primarily stream sediments, with occasional soils, in the parts of the U.S. not covered by the NURE-HSSR Program. This data set contains chemical analyses for more than 70,000 samples. The USGS, in collaboration with the Mexican Geological Survey and the Geological Survey of Canada, initiated soil sampling for the North American Soil Geochemical Landscapes Project in 2007. Sampling of three horizons or depths at more than 4800 sites in the U.S. was completed in 2010, and chemical analyses are currently ongoing. The NRCS initiated a project in the 1990s to analyze the various soil horizons from selected pedons throughout the U.S. This data set currently contains data from more than 1400 sites. This paper (1) discusses each data set in terms of its purpose, sample collection protocols, and analytical methods; and (2) evaluates each data set in terms of its appropriateness as a national-scale geochemical database and its usefulness for national-scale geochemical mapping.
Development of Sorbents for Extraction and Stabilization of Nucleic Acids
2016-09-13
ensure safe food and water supplies and to maintain the health and readiness of deployed troops. Identification of molecular signatures (genomic...biological, environmental, forensics, and food safety, drive the need for preservation of nucleic acid integrity during sample collection, transportation... antimicrobial activity as well as the potential for multiple and complex cationic interactions with nucleic acids (Fig. 10). Two different approaches were used
ERIC Educational Resources Information Center
Falasco, Dee; Heer, David M.
How the fertility of currently undocumented migrants might be affected by amnesty was examined within the context of Economic Theory of Fertility. Data were collected in 1980-81 from a sample of births recorded in Los Angeles County in which the mother or father was reported to be of Mexican descent. Multiple regression analyses for male and…
Feasibility Study for an Autonomous UAV - Magnetometer System
2007-11-01
collect data from multiple magnetometers at high sampling rates (~100 Hz), and associated with these acquisition systems are highly accurate...component for an UAV helicopter- magnetometer system is the ability to have precise positioning (both for flightpath execution and for data acquisition...discussed under section 6.3. Figure 6.11 shows the fluxgate data used to compensate a total field magnetometer as previously described. The red
Geokinetic Environment Investigations.
1981-03-31
geoceivers. Small DC solenoids had to be incorporated on each tiltmeter to overcome the Y tilt component stiction after geosensor azimuth slews... tiltmeter data during the sample period. Devel- opment of a LSI-11 executable multiple regression program was also initiated. Several runs of the ALS units...understanding of tilt and temperature data in- side the STM units, tilt and temperature data were collected at various locations on the tiltmeter and its
Factors influencing organic-horizon carbon pools in mixed-species stands of central Maine, USA
Joshua J. Puhlick; Shawn Fraver; Ivan J. Fernandez; Aaron R. Weiskittel; Laura S. Kenefic; Randy Kolka; Marie-Cecile Gruselle
2016-01-01
The overall goal of this study was to evaluate the correlation of multiple abiotic and biotic factors with organic-horizon (O-horizon) carbon (C) content on the Penobscot Experimental Forest in central Maine, USA. O-horizon samples were collected and their associated depths were recorded from stands managed with a range of silvicultural and harvesting treatments (i.e...
ERIC Educational Resources Information Center
Chen, Xinyin; Chang, Lei; He, Yunfeng; Liu, Hongyun
2005-01-01
This 2-year longitudinal study examined, in a sample of Chinese children (initial M age=11 years), the moderating effects of the peer group on relations between maternal supportive parenting and social and school adjustment. Data were collected from multiple sources including peer assessments, teacher ratings, school records, and maternal reports.…
Ichthyoplankton abundance and variance in a large river system concerns for long-term monitoring
Holland-Bartels, Leslie E.; Dewey, Michael R.; Zigler, Steven J.
1995-01-01
System-wide spatial patterns of ichthyoplankton abundance and variability were assessed in the upper Mississippi and lower Illinois rivers to address the experimental design and statistical confidence in density estimates. Ichthyoplankton was sampled from June to August 1989 in primary milieus (vegetated and non-vegated backwaters and impounded areas, main channels and main channel borders) in three navigation pools (8, 13 and 26) of the upper Mississippi River and in a downstream reach of the Illinois River. Ichthyoplankton densities varied among stations of similar aquatic landscapes (milieus) more than among subsamples within a station. An analysis of sampling effort indicated that the collection of single samples at many stations in a given milieu type is statistically and economically preferable to the collection of multiple subsamples at fewer stations. Cluster analyses also revealed that stations only generally grouped by their preassigned milieu types. Pilot studies such as this can define station groupings and sources of variation beyond an a priori habitat classification. Thus the minimum intensity of sampling required to achieve a desired statistical confidence can be identified before implementing monitoring efforts.
Woodruff, Laurel G.; Cannon, William F.; Knightes, Christopher D.; Chapelle, Francis H.; Bradley, Paul M.; Burns, Douglas A.; Brigham, Mark E.; Lowery, Mark A.
2010-01-01
Mercury is an element of on-going concern for human and aquatic health. Mercury sequestered in upland and wetland soils represents a source that may contribute to mercury contamination in sensitive ecosystems. An improved understanding of mercury cycling in stream ecosystems requires identification and quantification of mercury speciation and transport dynamics in upland and wetland soils within a watershed. This report presents data for soils collected in 2008 from two small watersheds in New York and South Carolina. In New York, 163 samples were taken from multiple depths or soil horizons at 70 separate locations near Fishing Brook, located in Hamilton County. At McTier Creek, in Aiken County, South Carolina, 81 samples from various soil horizons or soil depths were collected from 24 locations. Sample locations within each watershed were selected to characterize soil geochemistry in distinct land-cover compartments. Soils were analyzed for total mercury, selenium, total and carbonate carbon, and 42 other elements. A subset of the samples was also analyzed for methylmercury.
A simple and reliable method reducing sulfate to sulfide for multiple sulfur isotope analysis.
Geng, Lei; Savarino, Joel; Savarino, Clara A; Caillon, Nicolas; Cartigny, Pierre; Hattori, Shohei; Ishino, Sakiko; Yoshida, Naohiro
2018-02-28
Precise analysis of four sulfur isotopes of sulfate in geological and environmental samples provides the means to extract unique information in wide geological contexts. Reduction of sulfate to sulfide is the first step to access such information. The conventional reduction method suffers from a cumbersome distillation system, long reaction time and large volume of the reducing solution. We present a new and simple method enabling the process of multiple samples at one time with a much reduced volume of reducing solution. One mL of reducing solution made of HI and NaH 2 PO 2 was added to a septum glass tube with dry sulfate. The tube was heated at 124°C and the produced H 2 S was purged with inert gas (He or N 2 ) through gas-washing tubes and then collected by NaOH solution. The collected H 2 S was converted into Ag 2 S by adding AgNO 3 solution and the co-precipitated Ag 2 O was removed by adding a few drops of concentrated HNO 3 . Within 2-3 h, a 100% yield was observed for samples with 0.2-2.5 μmol Na 2 SO 4 . The reduction rate was much slower for BaSO 4 and a complete reduction was not observed. International sulfur reference materials, NBS-127, SO-5 and SO-6, were processed with this method, and the measured against accepted δ 34 S values yielded a linear regression line which had a slope of 0.99 ± 0.01 and a R 2 value of 0.998. The new methodology is easy to handle and allows us to process multiple samples at a time. It has also demonstrated good reproducibility in terms of H 2 S yield and for further isotope analysis. It is thus a good alternative to the conventional manual method, especially when processing samples with limited amount of sulfate available. © 2017 The Authors. Rapid Communications in Mass Spectrometry Pubished by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Sirorattanakul, Krittanon; Shen, Chong; Ou-Yang, Daniel
Diffusivity governs the dynamics of interacting particles suspended in a solvent. At high particle concentration, the interactions between particles become non-negligible, making the values of self and collective diffusivity diverge and concentration-dependent. Conventional methods for measuring this dependency, such as forced Rayleigh scattering, fluorescence correlation spectroscopy (FCS), and dynamic light scattering (DLS) require preparation of multiple samples. We present a new technique to measure this dependency by using only a single sample. Dielectrophoresis (DEP) is used to create concentration gradient in the solution. Across this concentration distribution, we use FCS to measure the concentration-dependent self diffusivity. Then, we switch off DEP to allow the particles to diffuse back to equilibrium. We obtain the time series of concentration distribution from fluorescence microscopy and use them to determine the concentration-dependent collective diffusivity. We compare the experimental results with computer simulations to verify the validity of this technique. Time and spatial resolution limits of FCS and imaging are also analyzed to estimate the limitation of the proposed technique. NSF DMR-0923299, Lehigh College of Arts and Sciences Undergraduate Research Grant, Lehigh Department of Physics, Emulsion Polymers Institute.
Development of a noise annoyance sensitivity scale
NASA Technical Reports Server (NTRS)
Bregman, H. L.; Pearson, R. G.
1972-01-01
Examining the problem of noise pollution from the psychological rather than the engineering view, a test of human sensitivity to noise was developed against the criterion of noise annoyance. Test development evolved from a previous study in which biographical, attitudinal, and personality data was collected on a sample of 166 subjects drawn from the adult community of Raleigh. Analysis revealed that only a small subset of the data collected was predictive of noise annoyance. Item analysis yielded 74 predictive items that composed the preliminary noise sensitivity test. This was administered to a sample of 80 adults who later rate the annoyance value of six sounds (equated in terms of peak sound pressure level) presented in a simulated home, living-room environment. A predictive model involving 20 test items was developed using multiple regression techniques, and an item weighting scheme was evaluated.
Singh, Sarman; Singh, Amit; Prajapati, Suneel; Kabra, Sushil K; Lodha, Rakesh; Mukherjee, Aparna; Singh, Varinder; Hesseling, Anneke C; Grewal, Harleen M S
2015-09-29
Tuberculosis (TB) in children is neglected, mainly due to lack of sensitive diagnostic tools. Recently Xpert MTB/RIF assay has revolutionized the diagnostic field, but its usefulness in pediatric TB has not been reported from India and no report is available on its use on long term archived samples. We recruited 130 pediatric patients with probable intrathoracic tuberculosis and their gastric aspirate (GA) and induced sputum (IS) samples on 2 consecutive days were collected between January 2009 and December 2012. All samples (n = 520) were subjected to smear examination, BACTEC-MGIT culture and in-house multiplex PCR. An aliquot of each sample was stored at -80 °C and tested in Xpert MTB/RIF assay in 2013. Sample wise and patient wise detection rate of smear microscopy was 4.4 % and 10 %, while for BACTEC-MGIT culture this rate was 24.4 % and 46.9 %, respectively. Of the 130 day 1 GA samples, 31.5 % and 27.7 % day 2 GA samples were culture positive. Only 17.7 % GA samples were positive on both days. Of the 130 IS samples collected on day 1 and day 2, 15.4 % and 23.1 % samples were culture positive. A combination of GA and IS yielded best results. Combining both GA and IS, the overall sensitivity of Xpert MTB/RIF on smear and culture positive samples was 95.6 %. In smear negative and culture positive samples its sensitivity was 62.5 %. The duration of sample storage impacted the Xpert MTB/RIF test performance (p = 0.0001). In smear positive samples stored for 650-849 days, its sensitivity was 85.7 % and 77.1 % for IS and GA samples which dropped to 33.3 % and 50 %, respectively, if stored for more than 1050 days. Confirmatory diagnosis of tuberculosis particularly in children is a medical challenge. No laboratory or radiological test can reach to a satisfactory level of diagnostic sensitivity. However, in this study we found that combination of multiple samples and multiple diagnostic tests can give much better yield, though not optimum. In present study, combination of 2 gastric aspirates (GA) and 2 induced sputum (IS) samples collected on two consecutive days, and tested on three diagnostic methods yielded a significantly high detection rate. Despite long term storage, the overall sensitivity of Xpert MTB/RIF on smear and -culture positive samples remained very high. But after storing these samples under subfreezing conditions the sensitivity of Xpert MTB/RIF decreased significantly. This is expected because even if the sample is smear and culture positive, the count of surviving mycobacteria goes down, after several years this count can reach to a undetectable level. This report shows that smear and culture positive samples stored at subfreezing conditions for several years can be used in the Xpert MTB/RIF assay, while maintaining appreciable diagnostic test sensitivity and specificity.
Bioaccumulation of metals by Fucus ceranoides in estuaries of South West England.
Varma, Ranjit; Turner, Andrew; Brown, Murray T
2011-11-01
Fucus ceranoides tolerates abiotic conditions encountered across the full range of estuarine salinities. We examined the bioaccumulation of metals in individuals and metal concentrations in accompanying sediment samples collected at different locations along estuaries of South West England. Intra- and inter-estuarine variations in metal accumulation by F. ceranoides, after correction for particulate contamination using Fe as a proxy, were attributed to variations in the availabilities and concentrations of aqueous metals. Greatest accumulation was observed in estuaries that remain most heavily impacted by historical mining activities and for metals that were mobilised to the greatest extent during these operations (As, Cu, Sn, Zn). Arsenic concentrations displayed a seaward increase in estuaries in which multiple samples were taken, whereas Cd concentrations were always greatest in samples collected from the most landward locations. Ongoing research aims to better understand the mechanisms and kinetics of metal interactions with F. ceranoides and their dependence on salinity. Copyright © 2011 Elsevier Ltd. All rights reserved.
Indelicato, Serena; Bongiorno, David; Tuzzolino, Nicola; Mannino, Maria Rosaria; Muscarella, Rosalia; Fradella, Pasquale; Gargano, Maria Elena; Nicosia, Salvatore; Ceraulo, Leopoldo
2018-03-14
Multivariate analysis was performed on a large data set of groundwater and leachate samples collected during 9 years of operation of the Bellolampo municipal solid waste landfill (located above Palermo, Italy). The aim was to obtain the most likely correlations among the data. The analysis results are presented. Groundwater samples were collected in the period 2004-2013, whereas the leachate analysis refers to the period 2006-2013. For groundwater, statistical data evaluation revealed notable differences among the samples taken from the numerous wells located around the landfill. Characteristic parameters revealed by principal component analysis (PCA) were more deeply investigated, and corresponding thematic maps were drawn. The composition of the leachate was also thoroughly investigated. Several chemical macro-descriptors were calculated, and the results are presented. A comparison of PCA results for the leachate and groundwater data clearly reveals that the groundwater's main components substantially differ from those of the leachate. This outcome strongly suggests excluding leachate permeation through the multiple landfill lining.
Comparability among four invertebrate sampling methods, Fountain Creek Basin, Colorado, 2010-2012
Zuellig, Robert E.; Bruce, James F.; Stogner, Sr., Robert W.; Brown, Krystal D.
2014-01-01
The U.S. Geological Survey, in cooperation with Colorado Springs City Engineering and Colorado Springs Utilities, designed a study to determine if sampling method and sample timing resulted in comparable samples and assessments of biological condition. To accomplish this task, annual invertebrate samples were collected concurrently using four sampling methods at 15 U.S. Geological Survey streamflow gages in the Fountain Creek basin from 2010 to 2012. Collectively, the four methods are used by local (U.S. Geological Survey cooperative monitoring program) and State monitoring programs (Colorado Department of Public Health and Environment) in the Fountain Creek basin to produce two distinct sample types for each program that target single-and multiple-habitats. This study found distinguishable differences between single-and multi-habitat sample types using both community similarities and multi-metric index values, while methods from each program within sample type were comparable. This indicates that the Colorado Department of Public Health and Environment methods were compatible with the cooperative monitoring program methods within multi-and single-habitat sample types. Comparisons between September and October samples found distinguishable differences based on community similarities for both sample types, whereas only differences were found for single-habitat samples when multi-metric index values were considered. At one site, differences between September and October index values from single-habitat samples resulted in opposing assessments of biological condition. Direct application of the results to inform the revision of the existing Fountain Creek basin U.S. Geological Survey cooperative monitoring program are discussed.
Schreier, Christina; Kremer, Werner; Huber, Fritz; Neumann, Sindy; Pagel, Philipp; Lienemann, Kai; Pestel, Sabine
2013-01-01
Introduction. Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining 1H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing) and the health status of the animals, which may influence urine pH and osmolarity. Methods. We treated rats with a solvent, a diuretic, or a nephrotoxicant and collected urine samples. Samples were titrated to pH 3 to 9, or salt concentrations increased up to 20-fold. The effects of storage conditions and freeze-thaw cycles were monitored. Selected metabolites and multivariate data analysis were evaluated after 1H NMR spectroscopy. Results. We showed that variation of pH from 3 to 9 and increases in osmolarity up to 6-fold had no effect on the quantification of the metabolites or on multivariate data analysis. Storage led to changes after 14 days at 4°C or after 12 months at −20°C, independent of sample composition. Multiple freeze-thaw cycles did not affect data analysis. Conclusion. Reproducibility of NMR measurements is not dependent on sample composition under physiological or pathological conditions. PMID:23865070
Schreier, Christina; Kremer, Werner; Huber, Fritz; Neumann, Sindy; Pagel, Philipp; Lienemann, Kai; Pestel, Sabine
2013-01-01
Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining (1)H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing) and the health status of the animals, which may influence urine pH and osmolarity. We treated rats with a solvent, a diuretic, or a nephrotoxicant and collected urine samples. Samples were titrated to pH 3 to 9, or salt concentrations increased up to 20-fold. The effects of storage conditions and freeze-thaw cycles were monitored. Selected metabolites and multivariate data analysis were evaluated after (1)H NMR spectroscopy. We showed that variation of pH from 3 to 9 and increases in osmolarity up to 6-fold had no effect on the quantification of the metabolites or on multivariate data analysis. Storage led to changes after 14 days at 4°C or after 12 months at -20°C, independent of sample composition. Multiple freeze-thaw cycles did not affect data analysis. Reproducibility of NMR measurements is not dependent on sample composition under physiological or pathological conditions.
Booth, Charlotte; Songco, Annabel; Parsons, Sam; Heathcote, Lauren; Vincent, John; Keers, Robert; Fox, Elaine
2017-12-29
Optimal psychological development is dependent upon a complex interplay between individual and situational factors. Investigating the development of these factors in adolescence will help to improve understanding of emotional vulnerability and resilience. The CogBIAS longitudinal study (CogBIAS-L-S) aims to combine cognitive and genetic approaches to investigate risk and protective factors associated with the development of mood and impulsivity-related outcomes in an adolescent sample. CogBIAS-L-S is a three-wave longitudinal study of typically developing adolescents conducted over 4 years, with data collection at age 12, 14 and 16. At each wave participants will undergo multiple assessments including a range of selective cognitive processing tasks (e.g. attention bias, interpretation bias, memory bias) and psychological self-report measures (e.g. anxiety, depression, resilience). Saliva samples will also be collected at the baseline assessment for genetic analyses. Multilevel statistical analyses will be performed to investigate the developmental trajectory of cognitive biases on psychological functioning, as well as the influence of genetic moderation on these relationships. CogBIAS-L-S represents the first longitudinal study to assess multiple cognitive biases across adolescent development and the largest study of its kind to collect genetic data. It therefore provides a unique opportunity to understand how genes and the environment influence the development and maintenance of cognitive biases and provide insight into risk and protective factors that may be key targets for intervention.
Consensus Classification Using Non-Optimized Classifiers.
Brownfield, Brett; Lemos, Tony; Kalivas, John H
2018-04-03
Classifying samples into categories is a common problem in analytical chemistry and other fields. Classification is usually based on only one method, but numerous classifiers are available with some being complex, such as neural networks, and others are simple, such as k nearest neighbors. Regardless, most classification schemes require optimization of one or more tuning parameters for best classification accuracy, sensitivity, and specificity. A process not requiring exact selection of tuning parameter values would be useful. To improve classification, several ensemble approaches have been used in past work to combine classification results from multiple optimized single classifiers. The collection of classifications for a particular sample are then combined by a fusion process such as majority vote to form the final classification. Presented in this Article is a method to classify a sample by combining multiple classification methods without specifically classifying the sample by each method, that is, the classification methods are not optimized. The approach is demonstrated on three analytical data sets. The first is a beer authentication set with samples measured on five instruments, allowing fusion of multiple instruments by three ways. The second data set is composed of textile samples from three classes based on Raman spectra. This data set is used to demonstrate the ability to classify simultaneously with different data preprocessing strategies, thereby reducing the need to determine the ideal preprocessing method, a common prerequisite for accurate classification. The third data set contains three wine cultivars for three classes measured at 13 unique chemical and physical variables. In all cases, fusion of nonoptimized classifiers improves classification. Also presented are atypical uses of Procrustes analysis and extended inverted signal correction (EISC) for distinguishing sample similarities to respective classes.
Moving Beyond the Household: Innovations in Data Collection on Kinship
Madhavan, Sangeetha; Clark, Shelley; Beguy, Donatien; Kabiru, Caroline W.; Gross, Mark
2017-01-01
Across settings, it has been shown that the co-residential household is an insufficient measure of family structure and support. However, it continues to be the primary means of population data collection. To address this problem, we have developed a new instrument – Kinship Support Tree (KST) – to collect kinship structure and support data on residential and non-residential kin and tested it on a sample of 462 single mothers and their children in a slum community in Nairobi, Kenya. This instrument is unique in four important ways: 1) it is not limited to the co-residential household; 2) it distinguishes potential from functional kin; 3) it incorporates multiple geospatial measures; and 4) it collects data on kin relationships from the perspective of children. In this paper, we describe the KST instrument, assess the data collected in comparison to data from household rosters, and consider the challenges and feasibility of administration of the KST. PMID:28139166
Moving beyond the household: Innovations in data collection on kinship.
Madhavan, Sangeetha; Clark, Shelley; Beguy, Donatien; Kabiru, Caroline W; Gross, Mark
2017-03-01
Across settings, it has been shown that the co-residential household is an insufficient measure of family structure and support. However, it continues to be the primary means of population data collection. To address this problem, we developed a new instrument, the Kinship Support Tree (KST), to collect kinship structure and support data on co-residential and non-residential kin and tested it on a sample of 462 single mothers and their children in a slum community in Nairobi, Kenya. This instrument is unique in four important ways: (1) it is not limited to the co-residential household; (2) it distinguishes potential from functional kin; (3) it incorporates multiple geospatial measures; and (4) it collects data on kin relationships specifically for children. In this paper, we describe the KST instrument, assess the data collected in comparison to data from household rosters, and consider the challenges and feasibility of administration of the KST.
Causal inference and the data-fusion problem
Bareinboim, Elias; Pearl, Judea
2016-01-01
We review concepts, principles, and tools that unify current approaches to causal analysis and attend to new challenges presented by big data. In particular, we address the problem of data fusion—piecing together multiple datasets collected under heterogeneous conditions (i.e., different populations, regimes, and sampling methods) to obtain valid answers to queries of interest. The availability of multiple heterogeneous datasets presents new opportunities to big data analysts, because the knowledge that can be acquired from combined data would not be possible from any individual source alone. However, the biases that emerge in heterogeneous environments require new analytical tools. Some of these biases, including confounding, sampling selection, and cross-population biases, have been addressed in isolation, largely in restricted parametric models. We here present a general, nonparametric framework for handling these biases and, ultimately, a theoretical solution to the problem of data fusion in causal inference tasks. PMID:27382148
Multiplexed electronically programmable multimode ionization detector for chromatography
Wise, M.B.; Buchanan, M.V.
1988-05-19
Method and apparatus for detecting and differentiating organic compounds based on their electron affinity. An electron capture detector cell (ECD) is operated in a plurality of multiplexed electronically programmable operating modes to alter the detector response during a single sampling cycle to acquire multiple simultaneous chromatograms corresponding to each of the different operating modes. The cell is held at a constant subatmospheric pressure while the electron collection bias voltage applied to the cell is modulated electronically to allow acquisition of multiple chromatograms for a single sample elution from a chromatograph representing three distinctly different response modes. A system is provided which automatically controls the programmed application of bias pulses at different intervals and/or amplitudes to switch the detector from an ionization mode to the electron capture mode and various degrees therebetween to provide an improved means of tuning an ECD for multimode detection and improved specificity. 6 figs.
Multiplexed electronically programmable multimode ionization detector for chromatography
Wise, Marcus B.; Buchanan, Michelle V.
1989-01-01
Method and apparatus for detecting and differentiating organic compounds based on their electron affinity. An electron capture detector cell (ECD) is operated in a plurality of multiplexed electroncially programmable operating modes to alter the detector response during a single sampling cycle to acquire multiple simultaneous chromatograms corresponding to each of the different operating modes. The cell is held at a constant subatmospheric pressure while the electron collection bias voltage applied to the cell is modulated electronically to allow acquisition of multiple chromatograms for a single sample elution from a chromatograph representing three distinctly different response modes. A system is provided which automatically controls the programmed application of bias pulses at different intervals and/or amplitudes to switch the detector from an ionization mode to the electron capture mode and various degrees therebetween to provide an improved means of tuning an ECD for multimode detection and improved specificity.
An Independent Orbit Determination Simulation for the OSIRIS-REx Asteroid Sample Return Mission
NASA Technical Reports Server (NTRS)
Getzandanner, Kenneth; Rowlands, David; Mazarico, Erwan; Antreasian, Peter; Jackman, Coralie; Moreau, Michael
2016-01-01
After arriving at the near-Earth asteroid (101955) Bennu in late 2018, the OSIRIS-REx spacecraft will execute a series of observation campaigns and orbit phases to accurately characterize Bennu and ultimately collect a sample of pristine regolith from its surface. While in the vicinity of Bennu, the OSIRIS-REx navigation team will rely on a combination of ground-based radiometric tracking data and optical navigation (OpNav) images to generate and deliver precision orbit determination products. Long before arrival at Bennu, the navigation team is performing multiple orbit determination simulations and thread tests to verify navigation performance and ensure interfaces between multiple software suites function properly. In this paper, we will summarize the results of an independent orbit determination simulation of the Orbit B phase of the mission performed to test the interface between the OpNav image processing and orbit determination software packages.
ϒ(nS) polarizations versus particle multiplicity in pp collisions at √{ s} = 7 TeV
NASA Astrophysics Data System (ADS)
Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Asilar, E.; Bergauer, T.; Brandstetter, J.; Brondolin, E.; Dragicevic, M.; Erö, J.; Fabjan, C.; Flechl, M.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Hartl, C.; Hörmann, N.; Hrubec, J.; Jeitler, M.; Knünz, V.; König, A.; Krammer, M.; Krätschmer, I.; Liko, D.; Matsushita, T.; Mikulec, I.; Rabady, D.; Rad, N.; Rahbaran, B.; Rohringer, H.; Schieck, J.; Schöfbeck, R.; Strauss, J.; Treberer-Treberspurg, W.; Waltenberger, W.; Wulz, C.-E.; Mossolov, V.; Shumeiko, N.; Suarez Gonzalez, J.; Alderweireldt, S.; Cornelis, T.; de Wolf, E. A.; Janssen, X.; Knutsson, A.; Lauwers, J.; Luyckx, S.; van de Klundert, M.; van Haevermaet, H.; van Mechelen, P.; van Remortel, N.; van Spilbeeck, A.; Abu Zeid, S.; Blekman, F.; D'Hondt, J.; Daci, N.; de Bruyn, I.; Deroover, K.; Heracleous, N.; Keaveney, J.; Lowette, S.; Moreels, L.; Olbrechts, A.; Python, Q.; Strom, D.; Tavernier, S.; van Doninck, W.; van Mulders, P.; van Onsem, G. P.; van Parijs, I.; Barria, P.; Brun, H.; Caillol, C.; Clerbaux, B.; de Lentdecker, G.; Fang, W.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Karapostoli, G.; Lenzi, T.; Léonard, A.; Maerschalk, T.; Marinov, A.; Perniè, L.; Randle-Conde, A.; Seva, T.; Vander Velde, C.; Vanlaer, P.; Yonamine, R.; Zenoni, F.; Zhang, F.; Beernaert, K.; Benucci, L.; Cimmino, A.; Crucy, S.; Dobur, D.; Fagot, A.; Garcia, G.; Gul, M.; McCartin, J.; Ocampo Rios, A. A.; Poyraz, D.; Ryckbosch, D.; Salva, S.; Sigamani, M.; Tytgat, M.; van Driessche, W.; Yazgan, E.; Zaganidis, N.; Basegmez, S.; Beluffi, C.; Bondu, O.; Brochet, S.; Bruno, G.; Caudron, A.; Ceard, L.; Delaere, C.; Favart, D.; Forthomme, L.; Giammanco, A.; Jafari, A.; Jez, P.; Komm, M.; Lemaitre, V.; Mertens, A.; Musich, M.; Nuttens, C.; Perrini, L.; Piotrzkowski, K.; Popov, A.; Quertenmont, L.; Selvaggi, M.; Vidal Marono, M.; Beliy, N.; Hammad, G. H.; Aldá Júnior, W. L.; Alves, F. L.; Alves, G. A.; Brito, L.; Correa Martins Junior, M.; Hamer, M.; Hensel, C.; Moraes, A.; Pol, M. E.; Rebello Teles, P.; Belchior Batista Das Chagas, E.; Carvalho, W.; Chinellato, J.; Custódio, A.; da Costa, E. M.; de Jesus Damiao, D.; de Oliveira Martins, C.; Fonseca de Souza, S.; Huertas Guativa, L. M.; Malbouisson, H.; Matos Figueiredo, D.; Mora Herrera, C.; Mundim, L.; Nogima, H.; Prado da Silva, W. L.; Santoro, A.; Sznajder, A.; Tonelli Manganote, E. J.; Vilela Pereira, A.; Ahuja, S.; Bernardes, C. A.; de Souza Santos, A.; Dogra, S.; Fernandez Perez Tomei, T. R.; Gregores, E. M.; Mercadante, P. G.; Moon, C. S.; Novaes, S. F.; Padula, Sandra S.; Romero Abad, D.; Ruiz Vargas, J. C.; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Rodozov, M.; Stoykova, S.; Sultanov, G.; Vutova, M.; Dimitrov, A.; Glushkov, I.; Litov, L.; Pavlov, B.; Petkov, P.; Ahmad, M.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Cheng, T.; Du, R.; Jiang, C. H.; Leggat, D.; Plestina, R.; Romeo, F.; Shaheen, S. M.; Spiezia, A.; Tao, J.; Wang, C.; Wang, Z.; Zhang, H.; Asawatangtrakuldee, C.; Ban, Y.; Li, Q.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Avila, C.; Cabrera, A.; Chaparro Sierra, L. F.; Florez, C.; Gomez, J. P.; Gomez Moreno, B.; Sanabria, J. C.; Godinovic, N.; Lelas, D.; Puljak, I.; Ribeiro Cipriano, P. M.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Kadija, K.; Luetic, J.; Micanovic, S.; Sudic, L.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Bodlak, M.; Finger, M.; Finger, M.; Abdelalim, A. A.; Awad, A.; Mahrous, A.; Radi, A.; Calpas, B.; Kadastik, M.; Murumaa, M.; Raidal, M.; Tiko, A.; Veelken, C.; Eerola, P.; Pekkanen, J.; Voutilainen, M.; Härkönen, J.; Karimäki, V.; Kinnunen, R.; Lampén, T.; Lassila-Perini, K.; Lehti, S.; Lindén, T.; Luukka, P.; Peltola, T.; Tuominiemi, J.; Tuovinen, E.; Wendland, L.; Talvitie, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Fabbro, B.; Faure, J. L.; Favaro, C.; Ferri, F.; Ganjour, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Locci, E.; Machet, M.; Malcles, J.; Rander, J.; Rosowsky, A.; Titov, M.; Zghiche, A.; Abdulsalam, A.; Antropov, I.; Baffioni, S.; Beaudette, F.; Busson, P.; Cadamuro, L.; Chapon, E.; Charlot, C.; Davignon, O.; Filipovic, N.; Granier de Cassagnac, R.; Jo, M.; Lisniak, S.; Mastrolorenzo, L.; Miné, P.; Naranjo, I. N.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Pigard, P.; Regnard, S.; Salerno, R.; Sauvan, J. B.; Sirois, Y.; Strebler, T.; Yilmaz, Y.; Zabi, A.; Agram, J.-L.; Andrea, J.; Aubin, A.; Bloch, D.; Brom, J.-M.; Buttignol, M.; Chabert, E. C.; Chanon, N.; Collard, C.; Conte, E.; Coubez, X.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Goetzmann, C.; Le Bihan, A.-C.; Merlin, J. A.; Skovpen, K.; van Hove, P.; Gadrat, S.; Beauceron, S.; Bernet, C.; Boudoul, G.; Bouvier, E.; Carrillo Montoya, C. A.; Chierici, R.; Contardo, D.; Courbon, B.; Depasse, P.; El Mamouni, H.; Fan, J.; Fay, J.; Gascon, S.; Gouzevitch, M.; Ille, B.; Lagarde, F.; Laktineh, I. B.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Ruiz Alvarez, J. D.; Sabes, D.; Sgandurra, L.; Sordini, V.; Vander Donckt, M.; Verdier, P.; Viret, S.; Toriashvili, T.; Tsamalaidze, Z.; Autermann, C.; Beranek, S.; Feld, L.; Heister, A.; Kiesel, M. K.; Klein, K.; Lipinski, M.; Ostapchuk, A.; Preuten, M.; Raupach, F.; Schael, S.; Schulte, J. F.; Verlage, T.; Weber, H.; Zhukov, V.; Ata, M.; Brodski, M.; Dietz-Laursonn, E.; Duchardt, D.; Endres, M.; Erdmann, M.; Erdweg, S.; Esch, T.; Fischer, R.; Güth, A.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Knutzen, S.; Kreuzer, P.; Merschmeyer, M.; Meyer, A.; Millet, P.; Mukherjee, S.; Olschewski, M.; Padeken, K.; Papacz, P.; Pook, T.; Radziej, M.; Reithler, H.; Rieger, M.; Scheuch, F.; Sonnenschein, L.; Teyssier, D.; Thüer, S.; Cherepanov, V.; Erdogan, Y.; Flügge, G.; Geenen, H.; Geisler, M.; Hoehle, F.; Kargoll, B.; Kress, T.; Künsken, A.; Lingemann, J.; Nehrkorn, A.; Nowack, A.; Nugent, I. M.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Asin, I.; Bartosik, N.; Behnke, O.; Behrens, U.; Borras, K.; Burgmeier, A.; Campbell, A.; Contreras-Campana, C.; Costanza, F.; Diez Pardos, C.; Dolinska, G.; Dooling, S.; Dorland, T.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Flucke, G.; Gallo, E.; Garay Garcia, J.; Geiser, A.; Gizhko, A.; Gunnellini, P.; Hauk, J.; Hempel, M.; Jung, H.; Kalogeropoulos, A.; Karacheban, O.; Kasemann, M.; Katsas, P.; Kieseler, J.; Kleinwort, C.; Korol, I.; Lange, W.; Leonard, J.; Lipka, K.; Lobanov, A.; Lohmann, W.; Mankel, R.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Mittag, G.; Mnich, J.; Mussgiller, A.; Naumann-Emme, S.; Nayak, A.; Ntomari, E.; Perrey, H.; Pitzl, D.; Placakyte, R.; Raspereza, A.; Roland, B.; Sahin, M. Ö.; Saxena, P.; Schoerner-Sadenius, T.; Seitz, C.; Spannagel, S.; Stefaniuk, N.; Trippkewitz, K. D.; Walsh, R.; Wissing, C.; Blobel, V.; Centis Vignali, M.; Draeger, A. R.; Erfle, J.; Garutti, E.; Goebel, K.; Gonzalez, D.; Görner, M.; Haller, J.; Hoffmann, M.; Höing, R. S.; Junkes, A.; Klanner, R.; Kogler, R.; Kovalchuk, N.; Lapsien, T.; Lenz, T.; Marchesini, I.; Marconi, D.; Meyer, M.; Nowatschin, D.; Ott, J.; Pantaleo, F.; Peiffer, T.; Perieanu, A.; Pietsch, N.; Poehlsen, J.; Rathjens, D.; Sander, C.; Scharf, C.; Schleper, P.; Schlieckau, E.; Schmidt, A.; Schumann, S.; Schwandt, J.; Sola, V.; Stadie, H.; Steinbrück, G.; Stober, F. M.; Tholen, H.; Troendle, D.; Usai, E.; Vanelderen, L.; Vanhoefer, A.; Vormwald, B.; Barth, C.; Baus, C.; Berger, J.; Böser, C.; Butz, E.; Chwalek, T.; Colombo, F.; de Boer, W.; Descroix, A.; Dierlamm, A.; Fink, S.; Frensch, F.; Friese, R.; Giffels, M.; Gilbert, A.; Haitz, D.; Hartmann, F.; Heindl, S. M.; Husemann, U.; Katkov, I.; Kornmayer, A.; Lobelle Pardo, P.; Maier, B.; Mildner, H.; Mozer, M. U.; Müller, T.; Müller, Th.; Plagge, M.; Quast, G.; Rabbertz, K.; Röcker, S.; Roscher, F.; Schröder, M.; Sieber, G.; Simonis, H. J.; Ulrich, R.; Wagner-Kuhr, J.; Wayand, S.; Weber, M.; Weiler, T.; Williamson, S.; Wöhrmann, C.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Giakoumopoulou, V. A.; Kyriakis, A.; Loukas, D.; Psallidas, A.; Topsis-Giotis, I.; Agapitos, A.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Tziaferi, E.; Evangelou, I.; Flouris, G.; Foudas, C.; Kokkas, P.; Loukas, N.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Strologas, J.; Bencze, G.; Hajdu, C.; Hazi, A.; Hidas, P.; Horvath, D.; Sikler, F.; Veszpremi, V.; Vesztergombi, G.; Zsigmond, A. J.; Beni, N.; Czellar, S.; Karancsi, J.; Molnar, J.; Szillasi, Z.; Bartók, M.; Makovec, A.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Choudhury, S.; Mal, P.; Mandal, K.; Sahoo, D. K.; Sahoo, N.; Swain, S. K.; Bansal, S.; Beri, S. B.; Bhatnagar, V.; Chawla, R.; Gupta, R.; Bhawandeep, U.; Kalsi, A. K.; Kaur, A.; Kaur, M.; Kumar, R.; Mehta, A.; Mittal, M.; Singh, J. B.; Walia, G.; Kumar, Ashok; Bhardwaj, A.; Choudhary, B. C.; Garg, R. B.; Malhotra, S.; Naimuddin, M.; Nishu, N.; Ranjan, K.; Sharma, R.; Sharma, V.; Bhattacharya, S.; Chatterjee, K.; Dey, S.; Dutta, S.; Majumdar, N.; Modak, A.; Mondal, K.; Mukhopadhyay, S.; Roy, A.; Roy, D.; Roy Chowdhury, S.; Sarkar, S.; Sharan, M.; Chudasama, R.; Dutta, D.; Jha, V.; Kumar, V.; Mohanty, A. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Banerjee, S.; Bhowmik, S.; Chatterjee, R. M.; Dewanjee, R. K.; Dugad, S.; Ganguly, S.; Ghosh, S.; Guchait, M.; Gurtu, A.; Jain, Sa.; Kole, G.; Kumar, S.; Mahakud, B.; Maity, M.; Majumder, G.; Mazumdar, K.; Mitra, S.; Mohanty, G. B.; Parida, B.; Sarkar, T.; Sur, N.; Sutar, B.; Wickramage, N.; Chauhan, S.; Dube, S.; Kapoor, A.; Kothekar, K.; Sharma, S.; Bakhshiansohi, H.; Behnamian, H.; Etesami, S. M.; Fahim, A.; Khakzad, M.; Mohammadi Najafabadi, M.; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Caputo, C.; Colaleo, A.; Creanza, D.; Cristella, L.; de Filippis, N.; de Palma, M.; Fiore, L.; Iaselli, G.; Maggi, G.; Maggi, M.; Miniello, G.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Ranieri, A.; Selvaggi, G.; Silvestris, L.; Venditti, R.; Abbiendi, G.; Battilana, C.; Bonacorsi, D.; Braibant-Giacomelli, S.; Brigliadori, L.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Chhibra, S. S.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Grandi, C.; Guiducci, L.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Cappello, G.; Chiorboli, M.; Costa, S.; di Mattia, A.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Gori, V.; Lenzi, P.; Meschini, M.; Paoletti, S.; Sguazzoni, G.; Viliani, L.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Primavera, F.; Calvelli, V.; Ferro, F.; Lo Vetere, M.; Monge, M. R.; Robutti, E.; Tosi, S.; Brianza, L.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Gerosa, R.; Ghezzi, A.; Govoni, P.; Malvezzi, S.; Manzoni, R. A.; Marzocchi, B.; Menasce, D.; Moroni, L.; Paganoni, M.; Pedrini, D.; Ragazzi, S.; Redaelli, N.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; di Guida, S.; Esposito, M.; Fabozzi, F.; Iorio, A. O. M.; Lanza, G.; Lista, L.; Meola, S.; Merola, M.; Paolucci, P.; Sciacca, C.; Thyssen, F.; Azzi, P.; Bacchetta, N.; Benato, L.; Bisello, D.; Boletti, A.; Carlin, R.; Checchia, P.; Dall'Osso, M.; Dorigo, T.; Dosselli, U.; Fanzago, F.; Gasparini, F.; Gasparini, U.; Gonella, F.; Gozzelino, A.; Lacaprara, S.; Margoni, M.; Meneguzzo, A. T.; Michelotto, M.; Pazzini, J.; Pozzobon, N.; Ronchese, P.; Simonetto, F.; Torassa, E.; Tosi, M.; Zanetti, M.; Zotto, P.; Zucchetta, A.; Zumerle, G.; Braghieri, A.; Magnani, A.; Montagna, P.; Ratti, S. P.; Re, V.; Riccardi, C.; Salvini, P.; Vai, I.; Vitulo, P.; Alunni Solestizi, L.; Bilei, G. M.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Mantovani, G.; Menichelli, M.; Saha, A.; Santocchia, A.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Bernardini, J.; Boccali, T.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Donato, S.; Fedi, G.; Foà, L.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Martini, L.; Messineo, A.; Palla, F.; Rizzi, A.; Savoy-Navarro, A.; Serban, A. T.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Barone, L.; Cavallari, F.; D'Imperio, G.; Del Re, D.; Diemoz, M.; Gelli, S.; Jorda, C.; Longo, E.; Margaroli, F.; Meridiani, P.; Organtini, G.; Paramatti, R.; Preiato, F.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Traczyk, P.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bellan, R.; Biino, C.; Cartiglia, N.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Finco, L.; Kiani, B.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Monteil, E.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Ravera, F.; Romero, A.; Ruspa, M.; Sacchi, R.; Solano, A.; Staiano, A.; Belforte, S.; Candelise, V.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; Gobbo, B.; La Licata, C.; Marone, M.; Schizzi, A.; Zanetti, A.; Kropivnitskaya, A.; Nam, S. K.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Kong, D. J.; Lee, S.; Oh, Y. D.; Sakharov, A.; Son, D. C.; Brochero Cifuentes, J. A.; Kim, H.; Kim, T. J.; Song, S.; Cho, S.; Choi, S.; Go, Y.; Gyun, D.; Hong, B.; Kim, H.; Kim, Y.; Lee, B.; Lee, K.; Lee, K. S.; Lee, S.; Lim, J.; Park, S. K.; Roh, Y.; Yoo, H. D.; Choi, M.; Kim, H.; Kim, J. H.; Lee, J. S. H.; Park, I. C.; Ryu, G.; Ryu, M. S.; Choi, Y.; Goh, J.; Kim, D.; Kwon, E.; Lee, J.; Yu, I.; Dudenas, V.; Juodagalvis, A.; Vaitkus, J.; Ahmed, I.; Ibrahim, Z. A.; Komaragiri, J. R.; Md Ali, M. A. B.; Mohamad Idris, F.; Wan Abdullah, W. A. T.; Yusli, M. N.; Zolkapli, Z.; Casimiro Linares, E.; Castilla-Valdez, H.; de La Cruz-Burelo, E.; Heredia-de La Cruz, I.; Hernandez-Almada, A.; Lopez-Fernandez, R.; Mejia Guisao, J.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Vazquez Valencia, F.; Pedraza, I.; Salazar Ibarguen, H. A.; Uribe Estrada, C.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Khan, W. A.; Khurshid, T.; Shoaib, M.; Waqas, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Romanowska-Rybinska, K.; Szleper, M.; Zalewski, P.; Brona, G.; Bunkowski, K.; Byszuk, A.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Misiura, M.; Olszewski, M.; Walczak, M.; Bargassa, P.; Beirão da Cruz E Silva, C.; di Francesco, A.; Faccioli, P.; Ferreira Parracho, P. G.; Gallinaro, M.; Hollar, J.; Leonardo, N.; Lloret Iglesias, L.; Nguyen, F.; Rodrigues Antunes, J.; Seixas, J.; Toldaiev, O.; Vadruccio, D.; Varela, J.; Vischia, P.; Afanasiev, S.; Bunin, P.; Gavrilenko, M.; Golutvin, I.; Gorbunov, I.; Kamenev, A.; Karjavin, V.; Lanev, A.; Malakhov, A.; Matveev, V.; Moisenz, P.; Palichik, V.; Perelygin, V.; Shmatov, S.; Shulha, S.; Skatchkov, N.; Smirnov, V.; Zarubin, A.; Golovtsov, V.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Levchenko, P.; Murzin, V.; Oreshkin, V.; Smirnov, I.; Sulimov, V.; Uvarov, L.; Vavilov, S.; Vorobyev, A.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Karneyeu, A.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Spiridonov, A.; Vlasov, E.; Zhokin, A.; Chadeeva, M.; Chistov, R.; Danilov, M.; Rusinov, V.; Tarkovskii, E.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Leonidov, A.; Mesyats, G.; Rusakov, S. V.; Baskakov, A.; Belyaev, A.; Boos, E.; Demiyanov, A.; Ershov, A.; Gribushin, A.; Kodolova, O.; Korotkikh, V.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Snigirev, A.; Vardanyan, I.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Krychkine, V.; Petrov, V.; Ryutin, R.; Sobol, A.; Tourtchanovitch, L.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Adzic, P.; Cirkovic, P.; Devetak, D.; Milosevic, J.; Rekovic, V.; Alcaraz Maestre, J.; Calvo, E.; Cerrada, M.; Chamizo Llatas, M.; Colino, N.; de La Cruz, B.; Delgado Peris, A.; Escalante Del Valle, A.; Fernandez Bedoya, C.; Fernández Ramos, J. P.; Flix, J.; Fouz, M. C.; Garcia-Abia, P.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Navarro de Martino, E.; Pérez-Calero Yzquierdo, A.; Puerta Pelayo, J.; Quintario Olmeda, A.; Redondo, I.; Romero, L.; Santaolalla, J.; Soares, M. S.; Albajar, C.; de Trocóniz, J. F.; Missiroli, M.; Moran, D.; Cuevas, J.; Fernandez Menendez, J.; Folgueras, S.; Gonzalez Caballero, I.; Palencia Cortezon, E.; Vizan Garcia, J. M.; Cabrillo, I. J.; Calderon, A.; Castiñeiras de Saa, J. R.; Curras, E.; de Castro Manzano, P.; Fernandez, M.; Garcia-Ferrero, J.; Gomez, G.; Lopez Virto, A.; Marco, J.; Marco, R.; Martinez Rivero, C.; Matorras, F.; Piedra Gomez, J.; Rodrigo, T.; Rodríguez-Marrero, A. Y.; Ruiz-Jimeno, A.; Scodellaro, L.; Trevisani, N.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Auffray, E.; Auzinger, G.; Bachtis, M.; Baillon, P.; Ball, A. H.; Barney, D.; Benaglia, A.; Bendavid, J.; Benhabib, L.; Berruti, G. M.; Bloch, P.; Bocci, A.; Bonato, A.; Botta, C.; Breuker, H.; Camporesi, T.; Castello, R.; Cerminara, G.; D'Alfonso, M.; D'Enterria, D.; Dabrowski, A.; Daponte, V.; David, A.; de Gruttola, M.; de Guio, F.; de Roeck, A.; de Visscher, S.; di Marco, E.; Dobson, M.; Dordevic, M.; Dorney, B.; Du Pree, T.; Duggan, D.; Dünser, M.; Dupont, N.; Elliott-Peisert, A.; Franzoni, G.; Fulcher, J.; Funk, W.; Gigi, D.; Gill, K.; Giordano, D.; Girone, M.; Glege, F.; Guida, R.; Gundacker, S.; Guthoff, M.; Hammer, J.; Harris, P.; Hegeman, J.; Innocente, V.; Janot, P.; Kirschenmann, H.; Kortelainen, M. J.; Kousouris, K.; Krajczar, K.; Lecoq, P.; Lourenço, C.; Lucchini, M. T.; Magini, N.; Malgeri, L.; Mannelli, M.; Martelli, A.; Masetti, L.; Meijers, F.; Mersi, S.; Meschi, E.; Moortgat, F.; Morovic, S.; Mulders, M.; Nemallapudi, M. V.; Neugebauer, H.; Orfanelli, S.; Orsini, L.; Pape, L.; Perez, E.; Peruzzi, M.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Pierini, M.; Piparo, D.; Racz, A.; Reis, T.; Rolandi, G.; Rovere, M.; Ruan, M.; Sakulin, H.; Schäfer, C.; Schwick, C.; Seidel, M.; Sharma, A.; Silva, P.; Simon, M.; Sphicas, P.; Steggemann, J.; Stieger, B.; Stoye, M.; Takahashi, Y.; Treille, D.; Triossi, A.; Tsirou, A.; Veres, G. I.; Wardle, N.; Wöhri, H. K.; Zagozdzinska, A.; Zeuner, W. D.; Bertl, W.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Rohe, T.; Bachmair, F.; Bäni, L.; Bianchini, L.; Casal, B.; Dissertori, G.; Dittmar, M.; Donegà, M.; Eller, P.; Grab, C.; Heidegger, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Lecomte, P.; Lustermann, W.; Mangano, B.; Marionneau, M.; Martinez Ruiz Del Arbol, P.; Masciovecchio, M.; Meinhard, M. T.; Meister, D.; Micheli, F.; Musella, P.; Nessi-Tedaldi, F.; Pandolfi, F.; Pata, J.; Pauss, F.; Perrozzi, L.; Quittnat, M.; Rossini, M.; Schönenberger, M.; Starodumov, A.; Takahashi, M.; Tavolaro, V. R.; Theofilatos, K.; Wallny, R.; Aarrestad, T. K.; Amsler, C.; Caminada, L.; Canelli, M. F.; Chiochia, V.; de Cosa, A.; Galloni, C.; Hinzmann, A.; Hreus, T.; Kilminster, B.; Lange, C.; Ngadiuba, J.; Pinna, D.; Rauco, G.; Robmann, P.; Salerno, D.; Yang, Y.; Cardaci, M.; Chen, K. H.; Doan, T. H.; Jain, Sh.; Khurana, R.; Konyushikhin, M.; Kuo, C. M.; Lin, W.; Lu, Y. J.; Pozdnyakov, A.; Yu, S. S.; Kumar, Arun; Chang, P.; Chang, Y. H.; Chang, Y. W.; Chao, Y.; Chen, K. F.; Chen, P. H.; Dietz, C.; Fiori, F.; Grundler, U.; Hou, W.-S.; Hsiung, Y.; Liu, Y. F.; Lu, R.-S.; Miñano Moya, M.; Petrakou, E.; Tsai, J. F.; Tzeng, Y. M.; Asavapibhop, B.; Kovitanggoon, K.; Singh, G.; Srimanobhas, N.; Suwonjandee, N.; Adiguzel, A.; Cerci, S.; Damarseckin, S.; Demiroglu, Z. S.; Dozen, C.; Dumanoglu, I.; Girgis, S.; Gokbulut, G.; Guler, Y.; Gurpinar, E.; Hos, I.; Kangal, E. E.; Kayis Topaksu, A.; Onengut, G.; Ozdemir, K.; Polatoz, A.; Tali, B.; Topakli, H.; Zorbilmez, C.; Bilin, B.; Bilmis, S.; Isildak, B.; Karapinar, G.; Yalvac, M.; Zeyrek, M.; Gülmez, E.; Kaya, M.; Kaya, O.; Yetkin, E. A.; Yetkin, T.; Cakir, A.; Cankocak, K.; Sen, S.; Vardarlı, F. I.; Grynyov, B.; Levchuk, L.; Sorokin, P.; Aggleton, R.; Ball, F.; Beck, L.; Brooke, J. J.; Clement, E.; Cussans, D.; Flacher, H.; Goldstein, J.; Grimes, M.; Heath, G. P.; Heath, H. F.; Jacob, J.; Kreczko, L.; Lucas, C.; Meng, Z.; Newbold, D. M.; Paramesvaran, S.; Poll, A.; Sakuma, T.; Seif El Nasr-Storey, S.; Senkin, S.; Smith, D.; Smith, V. J.; Belyaev, A.; Brew, C.; Brown, R. M.; Calligaris, L.; Cieri, D.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Worm, S. D.; Baber, M.; Bainbridge, R.; Buchmuller, O.; Bundock, A.; Burton, D.; Casasso, S.; Citron, M.; Colling, D.; Corpe, L.; Dauncey, P.; Davies, G.; de Wit, A.; Della Negra, M.; Dunne, P.; Elwood, A.; Futyan, D.; Hall, G.; Iles, G.; Lane, R.; Lucas, R.; Lyons, L.; Magnan, A.-M.; Malik, S.; Nash, J.; Nikitenko, A.; Pela, J.; Pesaresi, M.; Raymond, D. M.; Richards, A.; Rose, A.; Seez, C.; Tapper, A.; Uchida, K.; Vazquez Acosta, M.; Virdee, T.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Leslie, D.; Reid, I. D.; Symonds, P.; Teodorescu, L.; Turner, M.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Charaf, O.; Cooper, S. I.; Henderson, C.; Rumerio, P.; Arcaro, D.; Avetisyan, A.; Bose, T.; Gastler, D.; Rankin, D.; Richardson, C.; Rohlf, J.; Sulak, L.; Zou, D.; Alimena, J.; Benelli, G.; Berry, E.; Cutts, D.; Ferapontov, A.; Garabedian, A.; Hakala, J.; Heintz, U.; Jesus, O.; Laird, E.; Landsberg, G.; Mao, Z.; Narain, M.; Piperov, S.; Sagir, S.; Syarif, R.; Breedon, R.; Breto, G.; Calderon de La Barca Sanchez, M.; Chauhan, S.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Funk, G.; Gardner, M.; Ko, W.; Lander, R.; McLean, C.; Mulhearn, M.; Pellett, D.; Pilot, J.; Ricci-Tam, F.; Shalhout, S.; Smith, J.; Squires, M.; Stolp, D.; Tripathi, M.; Wilbur, S.; Yohay, R.; Cousins, R.; Everaerts, P.; Florent, A.; Hauser, J.; Ignatenko, M.; Saltzberg, D.; Takasugi, E.; Valuev, V.; Weber, M.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Hanson, G.; Heilman, J.; Ivova Paneva, M.; Jandir, P.; Kennedy, E.; Lacroix, F.; Long, O. R.; Malberti, M.; Olmedo Negrete, M.; Shrinivas, A.; Wei, H.; Wimpenny, S.; Yates, B. R.; Branson, J. G.; Cerati, G. B.; Cittolin, S.; D'Agnolo, R. T.; Derdzinski, M.; Holzner, A.; Kelley, R.; Klein, D.; Letts, J.; MacNeill, I.; Olivito, D.; Padhi, S.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Vartak, A.; Wasserbaech, S.; Welke, C.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Bradmiller-Feld, J.; Campagnari, C.; Dishaw, A.; Dutta, V.; Flowers, K.; Franco Sevilla, M.; Geffert, P.; George, C.; Golf, F.; Gouskos, L.; Gran, J.; Incandela, J.; McColl, N.; Mullin, S. D.; Richman, J.; Stuart, D.; Suarez, I.; West, C.; Yoo, J.; Anderson, D.; Apresyan, A.; Bornheim, A.; Bunn, J.; Chen, Y.; Duarte, J.; Mott, A.; Newman, H. B.; Pena, C.; Spiropulu, M.; Vlimant, J. R.; Xie, S.; Zhu, R. Y.; Andrews, M. B.; Azzolini, V.; Calamba, A.; Carlson, B.; Ferguson, T.; Paulini, M.; Russ, J.; Sun, M.; Vogel, H.; Vorobiev, I.; Cumalat, J. P.; Ford, W. T.; Gaz, A.; Jensen, F.; Johnson, A.; Krohn, M.; Mulholland, T.; Nauenberg, U.; Stenson, K.; Wagner, S. R.; Alexander, J.; Chatterjee, A.; Chaves, J.; Chu, J.; Dittmer, S.; Eggert, N.; Mirman, N.; Nicolas Kaufman, G.; Patterson, J. R.; Rinkevicius, A.; Ryd, A.; Skinnari, L.; Soffi, L.; Sun, W.; Tan, S. M.; Teo, W. D.; Thom, J.; Thompson, J.; Tucker, J.; Weng, Y.; Wittich, P.; Abdullin, S.; Albrow, M.; Apollinari, G.; Banerjee, S.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Cheung, H. W. K.; Chlebana, F.; Cihangir, S.; Elvira, V. D.; Fisk, I.; Freeman, J.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Hanlon, J.; Hare, D.; Harris, R. M.; Hasegawa, S.; Hirschauer, J.; Hu, Z.; Jayatilaka, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Klima, B.; Kreis, B.; Lammel, S.; Lewis, J.; Linacre, J.; Lincoln, D.; Lipton, R.; Liu, T.; Lopes de Sá, R.; Lykken, J.; Maeshima, K.; Marraffino, J. M.; Maruyama, S.; Mason, D.; McBride, P.; Merkel, P.; Mrenna, S.; Nahn, S.; Newman-Holmes, C.; O'Dell, V.; Pedro, K.; Prokofyev, O.; Rakness, G.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Stoynev, S.; Strobbe, N.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vernieri, C.; Verzocchi, M.; Vidal, R.; Wang, M.; Weber, H. A.; Whitbeck, A.; Acosta, D.; Avery, P.; Bortignon, P.; Bourilkov, D.; Brinkerhoff, A.; Carnes, A.; Carver, M.; Curry, D.; Das, S.; Field, R. D.; Furic, I. K.; Konigsberg, J.; Korytov, A.; Kotov, K.; Ma, P.; Matchev, K.; Mei, H.; Milenovic, P.; Mitselmakher, G.; Rank, D.; Rossin, R.; Shchutska, L.; Snowball, M.; Sperka, D.; Terentyev, N.; Thomas, L.; Wang, J.; Wang, S.; Yelton, J.; Hewamanage, S.; Linn, S.; Markowitz, P.; Martinez, G.; Rodriguez, J. L.; Ackert, A.; Adams, J. R.; Adams, T.; Askew, A.; Bein, S.; Bochenek, J.; Diamond, B.; Haas, J.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Khatiwada, A.; Prosper, H.; Weinberg, M.; Baarmand, M. M.; Bhopatkar, V.; Colafranceschi, S.; Hohlmann, M.; Kalakhety, H.; Noonan, D.; Roy, T.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Bucinskaite, I.; Cavanaugh, R.; Evdokimov, O.; Gauthier, L.; Gerber, C. E.; Hofman, D. J.; Kurt, P.; O'Brien, C.; Sandoval Gonzalez, I. D.; Turner, P.; Varelas, N.; Wu, Z.; Zakaria, M.; Zhang, J.; Bilki, B.; Clarida, W.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Snyder, C.; Tiras, E.; Wetzel, J.; Yi, K.; Anderson, I.; Barnett, B. A.; Blumenfeld, B.; Cocoros, A.; Eminizer, N.; Fehling, D.; Feng, L.; Gritsan, A. V.; Maksimovic, P.; Osherson, M.; Roskes, J.; Sarica, U.; Swartz, M.; Xiao, M.; Xin, Y.; You, C.; Baringer, P.; Bean, A.; Bruner, C.; Kenny, R. P., III; Majumder, D.; Malek, M.; McBrayer, W.; Murray, M.; Sanders, S.; Stringer, R.; Wang, Q.; Ivanov, A.; Kaadze, K.; Khalil, S.; Makouski, M.; Maravin, Y.; Mohammadi, A.; Saini, L. K.; Skhirtladze, N.; Toda, S.; Lange, D.; Rebassoo, F.; Wright, D.; Anelli, C.; Baden, A.; Baron, O.; Belloni, A.; Calvert, B.; Eno, S. C.; Ferraioli, C.; Gomez, J. A.; Hadley, N. J.; Jabeen, S.; Kellogg, R. G.; Kolberg, T.; Kunkle, J.; Lu, Y.; Mignerey, A. C.; Shin, Y. H.; Skuja, A.; Tonjes, M. B.; Tonwar, S. C.; Apyan, A.; Barbieri, R.; Baty, A.; Bi, R.; Bierwagen, K.; Brandt, S.; Busza, W.; Cali, I. A.; Demiragli, Z.; Di Matteo, L.; Gomez Ceballos, G.; Goncharov, M.; Gulhan, D.; Iiyama, Y.; Innocenti, G. M.; Klute, M.; Kovalskyi, D.; Lai, Y. S.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Marini, A. C.; McGinn, C.; Mironov, C.; Narayanan, S.; Niu, X.; Paus, C.; Roland, C.; Roland, G.; Salfeld-Nebgen, J.; Stephans, G. S. F.; Sumorok, K.; Tatar, K.; Varma, M.; Velicanu, D.; Veverka, J.; Wang, J.; Wang, T. W.; Wyslouch, B.; Yang, M.; Zhukova, V.; Benvenuti, A. C.; Dahmes, B.; Evans, A.; Finkel, A.; Gude, A.; Hansen, P.; Kalafut, S.; Kao, S. C.; Klapoetke, K.; Kubota, Y.; Lesko, Z.; Mans, J.; Nourbakhsh, S.; Ruckstuhl, N.; Rusack, R.; Tambe, N.; Turkewitz, J.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bartek, R.; Bloom, K.; Bose, S.; Claes, D. R.; Dominguez, A.; Fangmeier, C.; Gonzalez Suarez, R.; Kamalieddin, R.; Knowlton, D.; Kravchenko, I.; Meier, F.; Monroy, J.; Ratnikov, F.; Siado, J. E.; Snow, G. R.; Alyari, M.; Dolen, J.; George, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Kaisen, J.; Kharchilava, A.; Kumar, A.; Rappoccio, S.; Roozbahani, B.; Alverson, G.; Barberis, E.; Baumgartel, D.; Chasco, M.; Hortiangtham, A.; Massironi, A.; Morse, D. M.; Nash, D.; Orimoto, T.; Teixeira de Lima, R.; Trocino, D.; Wang, R.-J.; Wood, D.; Zhang, J.; Bhattacharya, S.; Hahn, K. A.; Kubik, A.; Low, J. F.; Mucia, N.; Odell, N.; Pollack, B.; Schmitt, M.; Sung, K.; Trovato, M.; Velasco, M.; Dev, N.; Hildreth, M.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Marinelli, N.; Meng, F.; Mueller, C.; Musienko, Y.; Planer, M.; Reinsvold, A.; Ruchti, R.; Smith, G.; Taroni, S.; Valls, N.; Wayne, M.; Wolf, M.; Woodard, A.; Antonelli, L.; Brinson, J.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Hart, A.; Hill, C.; Hughes, R.; Ji, W.; Ling, T. Y.; Liu, B.; Luo, W.; Puigh, D.; Rodenburg, M.; Winer, B. L.; Wulsin, H. W.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Koay, S. A.; Lujan, P.; Marlow, D.; Medvedeva, T.; Mooney, M.; Olsen, J.; Palmer, C.; Piroué, P.; Stickland, D.; Tully, C.; Zuranski, A.; Malik, S.; Barker, A.; Barnes, V. E.; Benedetti, D.; Bortoletto, D.; Gutay, L.; Jha, M. K.; Jones, M.; Jung, A. W.; Jung, K.; Kumar, A.; Miller, D. H.; Neumeister, N.; Radburn-Smith, B. C.; Shi, X.; Shipsey, I.; Silvers, D.; Sun, J.; Svyatkovskiy, A.; Wang, F.; Xie, W.; Xu, L.; Parashar, N.; Stupak, J.; Adair, A.; Akgun, B.; Chen, Z.; Ecklund, K. M.; Geurts, F. J. M.; Guilbaud, M.; Li, W.; Michlin, B.; Northup, M.; Padley, B. P.; Redjimi, R.; Roberts, J.; Rorie, J.; Tu, Z.; Zabel, J.; Betchart, B.; Bodek, A.; de Barbaro, P.; Demina, R.; Eshaq, Y.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Han, J.; Hindrichs, O.; Khukhunaishvili, A.; Lo, K. H.; Tan, P.; Verzetti, M.; Chou, J. P.; Contreras-Campana, E.; Ferencek, D.; Gershtein, Y.; Halkiadakis, E.; Heindl, M.; Hidas, D.; Hughes, E.; Kaplan, S.; Kunnawalkam Elayavalli, R.; Lath, A.; Nash, K.; Saka, H.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Foerster, M.; Riley, G.; Rose, K.; Spanier, S.; Thapa, K.; Bouhali, O.; Castaneda Hernandez, A.; Celik, A.; Dalchenko, M.; de Mattia, M.; Delgado, A.; Dildick, S.; Eusebi, R.; Gilmore, J.; Huang, T.; Kamon, T.; Krutelyov, V.; Mueller, R.; Osipenkov, I.; Pakhotin, Y.; Patel, R.; Perloff, A.; Rose, A.; Safonov, A.; Tatarinov, A.; Ulmer, K. A.; Akchurin, N.; Cowden, C.; Damgov, J.; Dragoiu, C.; Dudero, P. R.; Faulkner, J.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Libeiro, T.; Undleeb, S.; Volobouev, I.; Appelt, E.; Delannoy, A. G.; Greene, S.; Gurrola, A.; Janjam, R.; Johns, W.; Maguire, C.; Mao, Y.; Melo, A.; Ni, H.; Sheldon, P.; Tuo, S.; Velkovska, J.; Xu, Q.; Arenton, M. W.; Cox, B.; Francis, B.; Goodell, J.; Hirosky, R.; Ledovskoy, A.; Li, H.; Lin, C.; Neu, C.; Sinthuprasith, T.; Sun, X.; Wang, Y.; Wolfe, E.; Wood, J.; Xia, F.; Clarke, C.; Harr, R.; Karchin, P. E.; Kottachchi Kankanamge Don, C.; Lamichhane, P.; Sturdy, J.; Belknap, D. A.; Carlsmith, D.; Cepeda, M.; Dasu, S.; Dodd, L.; Duric, S.; Gomber, B.; Grothe, M.; Herndon, M.; Hervé, A.; Klabbers, P.; Lanaro, A.; Levine, A.; Long, K.; Loveless, R.; Mohapatra, A.; Ojalvo, I.; Perry, T.; Pierro, G. A.; Polese, G.; Ruggles, T.; Sarangi, T.; Savin, A.; Sharma, A.; Smith, N.; Smith, W. H.; Taylor, D.; Verwilligen, P.; Woods, N.; Cms Collaboration
2016-10-01
The polarizations of the ϒ (1 S) , ϒ (2 S) , and ϒ (3 S) mesons are measured as a function of the charged particle multiplicity in proton-proton collisions at √{ s} = 7 TeV. The measurements are performed with a dimuon data sample collected in 2011 by the CMS experiment, corresponding to an integrated luminosity of 4.9 fb-1. The results are extracted from the dimuon decay angular distributions, in two ranges of ϒ (nS) transverse momentum (10-15 and 15-35 GeV), and in the rapidity interval | y | < 1.2. The results do not show significant changes from low- to high-multiplicity pp collisions, although large uncertainties preclude definite statements in the ϒ (2 S) and ϒ (3 S) cases.
Shiu, A T
1999-04-01
The study investigated the contribution of the added part-time student role on the emotional experience of managing multiple roles of Hong Kong public health nurses (PHNs) who have children by comparing PHNs with and without the part-time student role. The research design employed the experience sampling method. Convenience sampling was used to recruit 20 subjects of which nine were undertaking part-time degree programmes. A watch was worn that gave a signal at six random times each day for 7 days to complete an experience sampling diary. PHNs on average responded to 34 signals (80%) and therefore completed 34 diaries, which collected data on work, college-work and family juggling and their effects on mood states. Results indicate that PHNs with an added part-time student role, although having fewer juggling occasions and higher emotional spouse support, had fewer family-related activities as well as a lower positive effect and a higher negative effect than PHNs without this role. These results suggest that taking up an added part-time student role creates additional role strain to nurses with children, and lend support to the argument that the stress of managing multiple roles is greatest and benefits least when work and non-work role responsibilities are both heavy.
Application of fuzzy set and Dempster-Shafer theory to organic geochemistry interpretation
NASA Technical Reports Server (NTRS)
Kim, C. S.; Isaksen, G. H.
1993-01-01
An application of fuzzy sets and Dempster Shafter Theory (DST) in modeling the interpretational process of organic geochemistry data for predicting the level of maturities of oil and source rock samples is presented. This was accomplished by (1) representing linguistic imprecision and imprecision associated with experience by a fuzzy set theory, (2) capturing the probabilistic nature of imperfect evidences by a DST, and (3) combining multiple evidences by utilizing John Yen's generalized Dempster-Shafter Theory (GDST), which allows DST to deal with fuzzy information. The current prototype provides collective beliefs on the predicted levels of maturity by combining multiple evidences through GDST's rule of combination.
Herrington, Jason S; Fan, Zhi-Hua Tina; Lioy, Paul J; Zhang, Junfeng Jim
2007-01-15
Airborne aldehyde and ketone (carbonyl) sampling methodologies based on derivatization with 2,4-dinitrophenylhydrazine (DNPH)-coated solid sorbents could unequivocally be considered the "gold" standard. Originally developed in the late 1970s, these methods have been extensively evaluated and developed up to the present day. However, these methods have been inadequately evaluated for the long-term (i.e., 24 h or greater) sampling collection efficiency (CE) of carbonyls other than formaldehyde. The current body of literature fails to demonstrate that DNPH-coated solid sorbent sampling methods have acceptable CEs for the long-term sampling of carbonyls other than formaldehyde. Despite this, such methods are widely used to report the concentrations of multiple carbonyls from long-term sampling, assuming approximately 100% CEs. Laboratory experiments were conducted in this study to evaluate the long-term formaldehyde and acetaldehyde sampling CEs for several commonly used DNPH-coated solid sorbents. Results from sampling known concentrations of formaldehyde and acetaldehyde generated in a dynamic atmosphere generation system demonstrate that the 24-hour formaldehyde sampling CEs ranged from 83 to 133%, confirming the findings made in previous studies. However, the 24-hour acetaldehyde sampling CEs ranged from 1 to 62%. Attempts to increase the acetaldehyde CEs by adding acid to the samples post sampling were unsuccessful. These results indicate that assuming approximately 100% CEs for 24-hour acetaldehyde sampling, as commonly done with DNPH-coated solid sorbent methods, would substantially under estimate acetaldehyde concentrations.
Sample flow switching techniques on microfluidic chips.
Pan, Yu-Jen; Lin, Jin-Jie; Luo, Win-Jet; Yang, Ruey-Jen
2006-02-15
This paper presents an experimental investigation into electrokinetically focused flow injection for bio-analytical applications. A novel microfluidic device for microfluidic sample handling is presented. The microfluidic chip is fabricated on glass substrates using conventional photolithographic and chemical etching processes and is bonded using a high-temperature fusion method. The proposed valve-less device is capable not only of directing a single sample flow to a specified output port, but also of driving multiple samples to separate outlet channels or even to a single outlet to facilitate sample mixing. The experimental results confirm that the sample flow can be electrokinetically pre-focused into a narrow stream and guided to the desired outlet port by means of a simple control voltage model. The microchip presented within this paper has considerable potential for use in a variety of applications, including high-throughput chemical analysis, cell fusion, fraction collection, sample mixing, and many other applications within the micro-total-analysis systems field.
Respondent-driven sampling as Markov chain Monte Carlo.
Goel, Sharad; Salganik, Matthew J
2009-07-30
Respondent-driven sampling (RDS) is a recently introduced, and now widely used, technique for estimating disease prevalence in hidden populations. RDS data are collected through a snowball mechanism, in which current sample members recruit future sample members. In this paper we present RDS as Markov chain Monte Carlo importance sampling, and we examine the effects of community structure and the recruitment procedure on the variance of RDS estimates. Past work has assumed that the variance of RDS estimates is primarily affected by segregation between healthy and infected individuals. We examine an illustrative model to show that this is not necessarily the case, and that bottlenecks anywhere in the networks can substantially affect estimates. We also show that variance is inflated by a common design feature in which the sample members are encouraged to recruit multiple future sample members. The paper concludes with suggestions for implementing and evaluating RDS studies.
Age differences in coping and locus of control: a study of managerial stress in Hong Kong.
Siu, O; Cooper, C L; Spector, P E; Donald, I
2001-12-01
The present study involved data collection from 3 samples of Hong Kong managers to examine mechanisms by which age would relate to work well-being. A total of 634 managers was drawn by random sampling and purposive sampling methods. The results showed that age was positively related to well-being (job satisfaction and mental well-being). Furthermore, older managers reported fewer sources of stress, better coping, and a more internal locus of control. Multiple regression analyses suggested that the relations of age with 2 well-being indicators can be attributed to various combinations of coping, work locus of control, sources of stress, managerial level, and organizational tenure.
Saliva Preservative for Diagnostic Purposes
NASA Technical Reports Server (NTRS)
Pierson, Duane L.; Mehta, Satish K.
2012-01-01
Saliva is an important body fluid for diagnostic purposes. Glycoproteins, glucose, steroids, DNA, and other molecules of diagnostic value are found in saliva. It is easier to collect as compared to blood or urine. Unfortunately, saliva also contains large numbers of bacteria that can release enzymes, which can degrade proteins and nucleic acids. These degradative enzymes destroy or reduce saliva s diagnostic value. This innovation describes the formulation of a chemical preservative that prevents microbial growth and inactivates the degradative enzymes. This extends the time that saliva can be stored or transported without losing its diagnostic value. Multiple samples of saliva can be collected if needed without causing discomfort to the subject and it does not require any special facilities to handle after it is collected.
McCabe, Sean Esteban; West, Brady T.
2016-01-01
Objectives This study examined the three-year course of multiple co-occurring substance use disorders (SUDs) based on longitudinal survey data from a large, nationally representative sample. Methods National estimates of the prevalence of DSM-IV SUDs were derived by analyzing data from structured, face-to-face diagnostic interviews as part of the National Epidemiologic Survey on Alcohol and Related Conditions (NESARC), which collected data from a large nationally representative sample of non-institutionalized U.S. adults at two waves (2001–2002 and 2004–2005; n = 34,653). Results U.S. adults with multiple past-year SUDs at Wave 1 were more likely than those with an individual past-year SUD at Wave 1 to report at least one past-year SUD at Wave 2. There were several sociodemographic characteristics and psychiatric disorders (i.e., male, younger age, never married, sexual minority identity, nicotine dependence, and anxiety, mood and personality disorders) associated with increased odds of developing multiple SUDs and having three-year persistence of multiple SUDs. The majority of adults with multiple past-year SUDs had a lifetime personality disorder and did not utilize substance abuse treatment or other help-seeking. Conclusions Multiple SUDs are associated with a more persistent three-year course of disease over time relative to individual-SUDs. Despite a more severe three-year course and higher rates of comorbidity with other psychiatric disorders, the majority of U.S. adults with multiple SUDs do not utilize substance abuse treatment or other help-seeking. Clinical assessments and the substance abuse literature tend to focus on drug-specific individual SUDs rather than considering multiple SUDs, which are more complex in nature. PMID:28406266
FISHtrees 3.0: Tumor Phylogenetics Using a Ploidy Probe.
Gertz, E Michael; Chowdhury, Salim Akhter; Lee, Woei-Jyh; Wangsa, Darawalee; Heselmeyer-Haddad, Kerstin; Ried, Thomas; Schwartz, Russell; Schäffer, Alejandro A
2016-01-01
Advances in fluorescence in situ hybridization (FISH) make it feasible to detect multiple copy-number changes in hundreds of cells of solid tumors. Studies using FISH, sequencing, and other technologies have revealed substantial intra-tumor heterogeneity. The evolution of subclones in tumors may be modeled by phylogenies. Tumors often harbor aneuploid or polyploid cell populations. Using a FISH probe to estimate changes in ploidy can guide the creation of trees that model changes in ploidy and individual gene copy-number variations. We present FISHtrees 3.0, which implements a ploidy-based tree building method based on mixed integer linear programming (MILP). The ploidy-based modeling in FISHtrees includes a new formulation of the problem of merging trees for changes of a single gene into trees modeling changes in multiple genes and the ploidy. When multiple samples are collected from each patient, varying over time or tumor regions, it is useful to evaluate similarities in tumor progression among the samples. Therefore, we further implemented in FISHtrees 3.0 a new method to build consensus graphs for multiple samples. We validate FISHtrees 3.0 on a simulated data and on FISH data from paired cases of cervical primary and metastatic tumors and on paired breast ductal carcinoma in situ (DCIS) and invasive ductal carcinoma (IDC). Tests on simulated data show improved accuracy of the ploidy-based approach relative to prior ploidyless methods. Tests on real data further demonstrate novel insights these methods offer into tumor progression processes. Trees for DCIS samples are significantly less complex than trees for paired IDC samples. Consensus graphs show substantial divergence among most paired samples from both sets. Low consensus between DCIS and IDC trees may help explain the difficulty in finding biomarkers that predict which DCIS cases are at most risk to progress to IDC. The FISHtrees software is available at ftp://ftp.ncbi.nih.gov/pub/FISHtrees.
FISHtrees 3.0: Tumor Phylogenetics Using a Ploidy Probe
Chowdhury, Salim Akhter; Lee, Woei-Jyh; Wangsa, Darawalee; Heselmeyer-Haddad, Kerstin; Ried, Thomas; Schwartz, Russell; Schäffer, Alejandro A.
2016-01-01
Advances in fluorescence in situ hybridization (FISH) make it feasible to detect multiple copy-number changes in hundreds of cells of solid tumors. Studies using FISH, sequencing, and other technologies have revealed substantial intra-tumor heterogeneity. The evolution of subclones in tumors may be modeled by phylogenies. Tumors often harbor aneuploid or polyploid cell populations. Using a FISH probe to estimate changes in ploidy can guide the creation of trees that model changes in ploidy and individual gene copy-number variations. We present FISHtrees 3.0, which implements a ploidy-based tree building method based on mixed integer linear programming (MILP). The ploidy-based modeling in FISHtrees includes a new formulation of the problem of merging trees for changes of a single gene into trees modeling changes in multiple genes and the ploidy. When multiple samples are collected from each patient, varying over time or tumor regions, it is useful to evaluate similarities in tumor progression among the samples. Therefore, we further implemented in FISHtrees 3.0 a new method to build consensus graphs for multiple samples. We validate FISHtrees 3.0 on a simulated data and on FISH data from paired cases of cervical primary and metastatic tumors and on paired breast ductal carcinoma in situ (DCIS) and invasive ductal carcinoma (IDC). Tests on simulated data show improved accuracy of the ploidy-based approach relative to prior ploidyless methods. Tests on real data further demonstrate novel insights these methods offer into tumor progression processes. Trees for DCIS samples are significantly less complex than trees for paired IDC samples. Consensus graphs show substantial divergence among most paired samples from both sets. Low consensus between DCIS and IDC trees may help explain the difficulty in finding biomarkers that predict which DCIS cases are at most risk to progress to IDC. The FISHtrees software is available at ftp://ftp.ncbi.nih.gov/pub/FISHtrees. PMID:27362268
Miller, Eleanor I; Murray, Gordon J; Rollins, Douglas E; Tiffany, Stephen T; Wilkins, Diana G
2011-07-01
The aim of this exploratory study was to develop and validate a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the quantification of nicotine, eight nicotine metabolites, and two minor tobacco alkaloids in fortified analyte-free hair and subsequently apply this method to hair samples collected from active smokers. An additional aim of the study was to include an evaluation of different wash procedures for the effective removal of environmentally deposited nicotine from tobacco smoke. An apparatus was designed for the purpose of exposing analyte-free hair to environmental tobacco smoke in order to deposit nicotine onto the hair surface. A shampoo/water wash procedure was identified as the most effective means of removing nicotine. This wash procedure was utilized for a comparison of washed and unwashed heavy smoker hair samples. Analytes and corresponding deuterated internal standards were extracted using a cation-exchange solid-phase cartridge. LC-MS-MS was carried out using an Acquity™ UPLC(®) system (Waters) and a Quattro Premier XE™ triple quadrupole MS (Waters) operated in electrospray positive ionization mode, with multiple reaction monitoring data acquisition. The developed method was applied to hair samples collected from heavy smokers (n = 3) and low-level smokers (n = 3) collected through IRB-approved protocols. Nicotine, cotinine, and nornicotine were quantified in both the washed and unwashed hair samples collected from three heavy smokers, whereas 3-hydroxycotinine was quantified in only one unwashed sample and nicotine-1'-oxide in the washed and unwashed hair samples from two heavy smokers. In contrast, nicotine-1'-oxide was quantified in one of the three low-level smoker samples; nicotine was quantified in the other two low-level smoker samples. No other analytes were detected in the hair of the three low-level smokers.
Song, Er-Qun; Hu, Jun; Wen, Cong-Ying; Tian, Zhi-Quan; Yu, Xu; Zhang, Zhi-Ling; Shi, Yun-Bo; Pang, Dai-Wen
2011-01-01
Fluorescent-magnetic-biotargeting multifunctional nanobioprobes (FMBMNs) have attracted great attention in recent years due to their increasing, important applications in biomedical research, clinical diagnosis, and biomedicine. We have previously developed such nanobioprobes for the detection and isolation of a single kind of tumor cells. Detection and isolation of multiple tumor markers or tumor cells from complex samples sensitively and with high efficiency is critical for the early diagnosis of tumors, especially malignant tumors or cancers, which will improve clinical diagnosis outcomes and help to select effective treatment approaches. Here, we expanded the application of the monoclonal antibody (mAb)-coupled FMBMNs for multiplexed assays. Multiple types of cancer cells, such as leukemia cells and prostate cancer cells, were detected and collected from mixed samples within 25 minutes by using a magnet and an ordinary fluorescence microscope. The capture efficiencies of mAb-coupled FMBMNs for the above mentioned two types of cells were 96% and 97% respectively. Furthermore, by using the mAb-coupled FMBMNs, specific and sensitive detection and rapid separation of a small number of spiked leukemia cells and prostate cancer cells in a large population of cultured normal cells (about 0.01% were tumor cells) were achieved simply and inexpensively without any sample pretreatment before cell analysis. Therefore, mAb-coupled multicolour FMBMNs may be used for very sensitive detection and rapid isolation of multiple cancer cells in biomedical research and medical diagnostics. PMID:21250650
Mckay, Garrett; Huang, Wenxi; Romera-Castillo, Cristina; Crouch, Jenna E; Rosario-Ortiz, Fernando L; Jaffé, Rudolf
2017-05-16
The antioxidant capacity and formation of photochemically produced reactive intermediates (RI) was studied for water samples collected from the Florida Everglades with different spatial (marsh versus estuarine) and temporal (wet versus dry season) characteristics. Measured RI included triplet excited states of dissolved organic matter ( 3 DOM*), singlet oxygen ( 1 O 2 ), and the hydroxyl radical ( • OH). Single and multiple linear regression modeling were performed using a broad range of extrinsic (to predict RI formation rates, R RI ) and intrinsic (to predict RI quantum yields, Φ RI ) parameters. Multiple linear regression models consistently led to better predictions of R RI and Φ RI for our data set but poor prediction of Φ RI for a previously published data set,1 probably because the predictors are intercorrelated (Pearson's r > 0.5). Single linear regression models were built with data compiled from previously published studies (n ≈ 120) in which E2:E3, S, and Φ RI values were measured, which revealed a high degree of similarity between RI-optical property relationships across DOM samples of diverse sources. This study reveals that • OH formation is, in general, decoupled from 3 DOM* and 1 O 2 formation, providing supporting evidence that 3 DOM* is not a • OH precursor. Finally, Φ RI for 1 O 2 and 3 DOM* correlated negatively with antioxidant activity (a surrogate for electron donating capacity) for the collected samples, which is consistent with intramolecular oxidation of DOM moieties by 3 DOM*.
Multiple object redshift determinations in clusters of galaxies using OCTOPUS
NASA Astrophysics Data System (ADS)
Mazure, A.; Proust, D.; Sodre, L.; Capelato, H. V.; Lund, G.
1988-04-01
The ESO multiobject facility, Octopus, was used to observe a sample of galaxy clusters such as SC2008-565 in an attempt to collect a large set of individual radial velocities. A dispersion of 114 A/mm was used, providing spectral coverage from 3800 to 5180 A. Octopus was found to be a well-adapted instrument for the rapid and simultaneous determination of redshifts in cataloged galaxy clusters.
Multiple object redshift determinations in clusters of galaxies using OCTOPUS
NASA Astrophysics Data System (ADS)
Mazure, A.; Proust, D.; Sodre, L.; Lund, G.; Capelato, H.
1987-03-01
The ESO multiobject facility, Octopus, was used to observe a sample of galaxy clusters such as SC2008-565 in an attempt to collect a large set of individual radial velocities. A dispersion of 114 A/mm was used, providing spectral coverage from 3800 to 5180 A. Octopus was found to be a well-adapted instrument for the rapid and simultaneous determination of redshifts in cataloged galaxy clusters.
Taich, Paula; Del Sole, Maria; Buontempo, Fabian; Williams, Gustavo; Winter, Ursula; Sgroi, Mariana; Chantada, Guillermo; Schaiquevich, Paula
2017-05-01
We characterized and compared the in-vivo absorption of topotecan into the aqueous humor after instillation of aqueous and ointment formulations. A lanolin/petrolatum ointment was used. New Zealand rabbits were instilled with topotecan solution (6 μg, group A), a single 10 μg dose of topotecan ointment (group B) or with five 10 μg doses of topotecan ointment (group C). Aqueous humor samples were collected at different times. Corneal samples were collected only for group A. Topotecan was quantified using HPLC, and pharmacokinetic parameters were calculated. Acute corneal epithelial toxicity was assessed after multiple instillations of topotecan ointment. Total topotecan maximum aqueous humor concentration (C max ) was 16.1, 69.9 and 287 ng/ml in group A, B and C, respectively. A single dose of topotecan ointment increased threefold and sevenfold the aqueous humor C max , and exposure compared to the aqueous formulation. Aqueous humor concentrations from group C eyes were substantially above the cytotoxic concentration for retinoblastoma cells. No corneal toxicity was evident after ointment instillation. Topotecan penetrated into the aqueous humor of the rabbit eye after multiple doses of an ointment in concentrations pharmacologically active against retinoblastoma cells without eliciting acute toxicity. Topotecan ointment may translate to the clinical treatment of anterior segment disseminated retinoblastoma. © 2016 Royal Pharmaceutical Society.
A dual mode breath sampler for the collection of the end-tidal and dead space fractions.
Salvo, P; Ferrari, C; Persia, R; Ghimenti, S; Lomonaco, T; Bellagambi, F; Di Francesco, F
2015-06-01
This work presents a breath sampler prototype automatically collecting end-tidal (single and multiple breaths) or dead space air fractions (multiple breaths). This result is achieved by real time measurements of the CO2 partial pressure and airflow during the expiratory and inspiratory phases. Suitable algorithms, used to control a solenoid valve, guarantee that a Nalophan(®) bag is filled with the selected breath fraction even if the subject under test hyperventilates. The breath sampler has low pressure drop (<0.5 kPa) and uses inert or disposable components to avoid bacteriological risk for the patients and contamination of the breath samples. A fully customisable software interface allows a real time control of the hardware and software status. The performances of the breath sampler were evaluated by comparing (a) the CO2 partial pressure calculated during the sampling with the CO2 pressure measured off-line within the Nalophan(®) bag; (b) the concentrations of four selected volatile organic compounds in dead space, end-tidal and mixed breath fractions. Results showed negligible deviations between calculated and off-line CO2 pressure values and the distributions of the selected compounds into dead space, end-tidal and mixed breath fractions were in agreement with their chemical-physical properties. Copyright © 2015. Published by Elsevier Ltd.
Hung, Chia-Wei; Huang, Kuo-Hao; Shih, Yung-Yen; Lin, Yu-Shih; Chen, Hsin-Hung; Wang, Chau-Chang; Ho, Chuang-Yi; Hung, Chin-Chang; Burdige, David J.
2016-01-01
Hydrocarbon vents have recently been reported to contribute considerable amounts of dissolved organic carbon (DOC) to the oceans. Many such hydrocarbon vents widely exist in the northern South China Sea (NSCS). To investigate if these hydrocarbon vent sites release DOC, we used a real-time video multiple-corer to collect bottom seawater and surface sediments at vent sites. We analyzed concentrations of DOC in these samples and estimated DOC fluxes. Elevated DOC concentrations in the porewaters were found at some sites suggesting that DOC may come from these hydrocarbon vents. Benthic fluxes of DOC from these sediments were 28 to 1264 μmol m−2 d−1 (on average ~321 μmol m−2 d−1) which are several times higher than most DOC fluxes in coastal and continental margin sediments. The results demonstrate that the real-time video multiple-corer can precisely collect samples at vent sites. The estimated benthic DOC flux from the methane venting sites (8.6 × 106 mol y−1), is 24% of the DOC discharge from the Pearl River to the South China Sea, indicating that these sediments make an important contribution to the DOC in deep waters. PMID:27432631
Jimmieson, Nerina L; Tucker, Michelle K; Walsh, Alexandra J
2017-05-01
Simultaneous exposure to time, cognitive, and emotional demands is a feature of the work environment for healthcare workers, yet effects of these common stressors in combination are not well established. Survey data were collected from 125 hospital employees (Sample 1, Study 1), 93 ambulance service employees (Sample 2, Study 1), and 380 aged care/disability workers (Study 2). Hierarchical multiple regressions were conducted. In Sample 1, high cognitive demand exacerbated high emotional demand on psychological strain and job burnout, whereas the negative effect of high emotional demand was not present at low cognitive demand. In Sample 2, a similar pattern between emotional demand and time demand on stress-remedial intentions was observed. In Study 2, emotional demand × time demand and time demand × cognitive demand interactions again revealed that high levels of two demands were stress-exacerbating and low levels of one demand neutralized the other. A three-way interaction on job satisfaction showed the negative impact of emotional demand was exacerbated when both time and cognitive demands were high, creating a "triple disadvantage" of job demands. The results demonstrate that reducing some job demands helps attenuate the stressful effects of other job demands on different employee outcomes.
Insights from two industrial hygiene pilot e-cigarette passive vaping studies.
Maloney, John C; Thompson, Michael K; Oldham, Michael J; Stiff, Charles L; Lilly, Patrick D; Patskan, George J; Shafer, Kenneth H; Sarkar, Mohamadi A
2016-01-01
While several reports have been published using research methods of estimating exposure risk to e-cigarette vapors in nonusers, only two have directly measured indoor air concentrations from vaping using validated industrial hygiene sampling methodology. Our first study was designed to measure indoor air concentrations of nicotine, menthol, propylene glycol, glycerol, and total particulates during the use of multiple e-cigarettes in a well-characterized room over a period of time. Our second study was a repeat of the first study, and it also evaluated levels of formaldehyde. Measurements were collected using active sampling, near real-time and direct measurement techniques. Air sampling incorporated industrial hygiene sampling methodology using analytical methods established by the National Institute of Occupational Safety and Health and the Occupational Safety and Health Administration. Active samples were collected over a 12-hr period, for 4 days. Background measurements were taken in the same room the day before and the day after vaping. Panelists (n = 185 Study 1; n = 145 Study 2) used menthol and non-menthol MarkTen prototype e-cigarettes. Vaping sessions (six, 1-hr) included 3 prototypes, with total number of puffs ranging from 36-216 per session. Results of the active samples were below the limit of quantitation of the analytical methods. Near real-time data were below the lowest concentration on the established calibration curves. Data from this study indicate that the majority of chemical constituents sampled were below quantifiable levels. Formaldehyde was detected at consistent levels during all sampling periods. These two studies found that indoor vaping of MarkTen prototype e-cigarette does not produce chemical constituents at quantifiable levels or background levels using standard industrial hygiene collection techniques and analytical methods.
Surveillance and molecular characterization of group A rotaviruses in Goroka, Papua New Guinea.
Horwood, Paul Francis; Luang-Suarkia, Dagwin; Bebes, Sauli; Boniface, Karen; Datta, Siddhartha Sankar; Siba, Peter Max; Kirkwood, Carl Dunn
2012-12-01
In this study, we investigated the molecular epidemiology of group A rotaviruses in cases of acute gastroenteritis in Goroka, Papua New Guinea. From April 2008 through November 2010, 813 diarrheal stool samples were collected from children < 5 years of age hospitalized with acute gastroenteritis. Rotavirus antigen was detected in 31.2% of samples using a commercial enzyme-linked immunosorbent assay. Genotyping revealed the presence of the globally circulating strains G1P[8] (50.0%), G3P[8] (23.0%), and G2P[4] (8.2%). The globally emerging strains G9 and G12 were detected in 1.2% and 6.1% of samples, respectively. Mixed infections were detected in a high proportion of samples (11.9%), with 9.0% and 3.7% of samples displaying multiple G and P genotypes, respectively.
Andreas, Nicholas J; Hyde, Matthew J; Herbert, Bronwen R; Jeffries, Suzan; Santhakumaran, Shalini; Mandalia, Sundhiya; Holmes, Elaine; Modi, Neena
2016-07-07
We tested the hypothesis that there is a positive association between maternal body mass index (BMI) and the concentration of appetite-regulating hormones leptin, insulin, ghrelin and resistin in breast milk. We also aimed to describe the change in breast milk hormone concentration within each feed, and over time. Mothers were recruited from the postpartum ward at a university hospital in London. Breast milk samples were collected at the participants' homes. We recruited 120 healthy, primiparous, breastfeeding mothers, aged over 18 years. Mothers who smoked, had multiple births or had diabetes were excluded. Foremilk and hindmilk samples were collected from 105 women at 1 week postpartum and 92 women at 3 months postpartum. We recorded maternal and infant anthropometric measurements at each sample collection and measured hormone concentrations using a multiplex assay. The concentration of leptin in foremilk correlated with maternal BMI at the time of sample collection, at 7 days (r=0.31, p=0.02) and 3 months postpartum (r=0.30, p=<0.00). Foremilk insulin correlated with maternal BMI at 3 months postpartum (r=0.22, p=0.04). Breast milk ghrelin and resistin were not correlated with maternal BMI. Ghrelin concentrations at 3 months postpartum were increased in foremilk compared with hindmilk (p=0.01). Concentrations of ghrelin were increased in hindmilk collected at 1 week postpartum compared with samples collected at 3 months postpartum (p=0.03). A trend towards decreased insulin concentrations in hindmilk was noted. Concentrations of leptin and resistin were not seen to alter over a feed. A positive correlation between maternal BMI and foremilk leptin concentration at both time points studied, and foremilk insulin at 3 months postpartum was observed. This may have implications for infant appetite regulation and obesity risk. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Pesticides in the Lower Clackamas River Basin, Oregon, 2000-01
Carpenter, Kurt D.
2004-01-01
In 2000-01, the U. S. Geological Survey sampled the Clackamas River and its major lower-basin tributaries during storm runoff conditions for 86 dissolved pesticides and selected breakdown products. Twenty-seven compounds, including 18 herbicides, 7 insecticides, and 2 pesticide breakdown products, were detected in 18 stream samples. The most commonly detected pesticides, in decreasing frequency, included atrazine, simazine, diazinon, metolachlor, and diuron, which variously occurred in 46-92% of samples collected from the tributaries. Of these, atrazine, simazine, and metolachlor, plus six other compounds, also were detected in the main-stem Clackamas River. Pesticides were detected more frequently and at higher concentrations in the four lowermost tributaries (Deep, Richardson, Rock, and Sieben Creeks). In these streams, 12 to 18 pesticides were detected per stream in samples collected during spring and fall. Pesticides always occurred with at least one other pesticide, and about half of the samples, including one sample from the Clackamas River in October 2000, contained six or more pesticides. Nine pesticides, including the insecticide diazinon and the herbicides 2,4-D, atrazine, dichlobenil, diuron, imazaquin, metolachlor, simazine, and trifluralin, were detected in five water samples of Clackamas River water. No pesticides were detected in three samples of treated Clackamas River water used for drinking-water supply. Concentrations of six compounds--carbaryl, chlorpyrifos, diazinon, dieldrin, malathion, and the breakdown product of DDT (p,p'-DDE)--exceeded established or recommended criteria for the protection of aquatic life in some of the tributaries, sometimes for multiple pesticides in one sample. Identifying the sources of pesticides detected in the Clackamas River Basin is difficult because of the diverse land use in the basin and the multiple-use nature of many of the pesticides detected. Of the 25 parent compounds detected, 22 have agricultural uses, 23 have urban uses, 16 are applied to golf courses, 11 are applied along roads and other right-of-ways, and 5 have or had forestry applications. Because only a small fraction of the thousands of pesticide products registered for use in Oregon were tested for in this study, future monitoring could benefit from knowledge of what pesticides are applied so that potential problems can be identified and managed.
Yin, Ge; Danielsson, Sara; Dahlberg, Anna-Karin; Zhou, Yihui; Qiu, Yanling; Nyberg, Elisabeth; Bignert, Anders
2017-10-01
Environmental monitoring typically assumes samples and sampling activities to be representative of the population being studied. Given a limited budget, an appropriate sampling strategy is essential to support detecting temporal trends of contaminants. In the present study, based on real chemical analysis data on polybrominated diphenyl ethers in snails collected from five subsites in Tianmu Lake, computer simulation is performed to evaluate three sampling strategies by the estimation of required sample size, to reach a detection of an annual change of 5% with a statistical power of 80% and 90% with a significant level of 5%. The results showed that sampling from an arbitrarily selected sampling spot is the worst strategy, requiring much more individual analyses to achieve the above mentioned criteria compared with the other two approaches. A fixed sampling site requires the lowest sample size but may not be representative for the intended study object e.g. a lake and is also sensitive to changes of that particular sampling site. In contrast, sampling at multiple sites along the shore each year, and using pooled samples when the cost to collect and prepare individual specimens are much lower than the cost for chemical analysis, would be the most robust and cost efficient strategy in the long run. Using statistical power as criterion, the results demonstrated quantitatively the consequences of various sampling strategies, and could guide users with respect of required sample sizes depending on sampling design for long term monitoring programs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Bruce, James F.; Roberts, James J.; Zuellig, Robert E.
2018-05-24
The U.S. Geological Survey (USGS), in cooperation with Colorado Springs City Engineering and Colorado Springs Utilities, analyzed previously collected invertebrate data to determine the comparability among four sampling methods and two versions (2010 and 2017) of the Colorado Benthic Macroinvertebrate Multimetric Index (MMI). For this study, annual macroinvertebrate samples were collected concurrently (in space and time) at 15 USGS surface-water gaging stations in the Fountain Creek Basin from 2010 to 2012 using four sampling methods. The USGS monitoring project in the basin uses two of the methods and the Colorado Department of Public Health and Environment recommends the other two. These methods belong to two distinct sample types, one that targets single habitats and one that targets multiple habitats. The study results indicate that there are significant differences in MMI values obtained from the single-habitat and multihabitat sample types but methods from each program within each sample type produced comparable values. This study also determined that MMI values calculated by different versions of the Colorado Benthic Macroinvertebrate MMI are indistinguishable. This indicates that the Colorado Department of Public Health and Environment methods are comparable with the USGS monitoring project methods for single-habitat and multihabitat sample types. This report discusses the direct application of the study results to inform the revision of the existing USGS monitoring project in the Fountain Creek Basin.
Hansen, Heidi; Ben-David, Merav; McDonald, David B
2008-03-01
In noninvasive genetic sampling, when genotyping error rates are high and recapture rates are low, misidentification of individuals can lead to overestimation of population size. Thus, estimating genotyping errors is imperative. Nonetheless, conducting multiple polymerase chain reactions (PCRs) at multiple loci is time-consuming and costly. To address the controversy regarding the minimum number of PCRs required for obtaining a consensus genotype, we compared consumer-style the performance of two genotyping protocols (multiple-tubes and 'comparative method') in respect to genotyping success and error rates. Our results from 48 faecal samples of river otters (Lontra canadensis) collected in Wyoming in 2003, and from blood samples of five captive river otters amplified with four different primers, suggest that use of the comparative genotyping protocol can minimize the number of PCRs per locus. For all but five samples at one locus, the same consensus genotypes were reached with fewer PCRs and with reduced error rates with this protocol compared to the multiple-tubes method. This finding is reassuring because genotyping errors can occur at relatively high rates even in tissues such as blood and hair. In addition, we found that loci that amplify readily and yield consensus genotypes, may still exhibit high error rates (7-32%) and that amplification with different primers resulted in different types and rates of error. Thus, assigning a genotype based on a single PCR for several loci could result in misidentification of individuals. We recommend that programs designed to statistically assign consensus genotypes should be modified to allow the different treatment of heterozygotes and homozygotes intrinsic to the comparative method. © 2007 The Authors.
Multiple immunofluorescence labelling of formalin-fixed paraffin-embedded (FFPE) tissue
Robertson, David; Savage, Kay; Reis-Filho, Jorge S; Isacke, Clare M
2008-01-01
Background Investigating the expression of candidate genes in tissue samples usually involves either immunohistochemical labelling of formalin-fixed paraffin-embedded (FFPE) sections or immunofluorescence labelling of cryosections. Although both of these methods provide essential data, both have important limitations as research tools. Consequently, there is a demand in the research community to be able to perform routine, high quality immunofluorescence labelling of FFPE tissues. Results We present here a robust optimised method for high resolution immunofluorescence labelling of FFPE tissues, which involves the combination of antigen retrieval, indirect immunofluorescence and confocal laser scanning microscopy. We demonstrate the utility of this method with examples of immunofluorescence labelling of human kidney, human breast and a tissue microarray of invasive human breast cancers. Finally, we demonstrate that stained slides can be stored in the short term at 4°C or in the longer term at -20°C prior to images being collected. This approach has the potential to unlock a large in vivo database for immunofluorescence investigations and has the major advantages over immunohistochemistry in that it provides higher resolution imaging of antigen localization and the ability to label multiple antigens simultaneously. Conclusion This method provides a link between the cell biology and pathology communities. For the cell biologist, it will enable them to utilise the vast archive of pathology specimens to advance their in vitro data into in vivo samples, in particular archival material and tissue microarrays. For the pathologist, it will enable them to utilise multiple antibodies on a single section to characterise particular cell populations or to test multiple biomarkers in limited samples and define with greater accuracy cellular heterogeneity in tissue samples. PMID:18366689
Fithian, William; Elith, Jane; Hastie, Trevor; Keith, David A
2015-04-01
Presence-only records may provide data on the distributions of rare species, but commonly suffer from large, unknown biases due to their typically haphazard collection schemes. Presence-absence or count data collected in systematic, planned surveys are more reliable but typically less abundant.We proposed a probabilistic model to allow for joint analysis of presence-only and survey data to exploit their complementary strengths. Our method pools presence-only and presence-absence data for many species and maximizes a joint likelihood, simultaneously estimating and adjusting for the sampling bias affecting the presence-only data. By assuming that the sampling bias is the same for all species, we can borrow strength across species to efficiently estimate the bias and improve our inference from presence-only data.We evaluate our model's performance on data for 36 eucalypt species in south-eastern Australia. We find that presence-only records exhibit a strong sampling bias towards the coast and towards Sydney, the largest city. Our data-pooling technique substantially improves the out-of-sample predictive performance of our model when the amount of available presence-absence data for a given species is scarceIf we have only presence-only data and no presence-absence data for a given species, but both types of data for several other species that suffer from the same spatial sampling bias, then our method can obtain an unbiased estimate of the first species' geographic range.
The Indian Council of Medical Research–India Diabetes (ICMR–INDIAB) Study: Methodological Details
Anjana, Ranjit Mohan; Pradeepa, Rajendra; Deepa, Mohan; Datta, Manjula; Sudha, Vasudevan; Unnikrishnan, Ranjit; Nath, Lalith M; Das, Ashok Kumar; Madhu, Sri Venkata; Rao, Paturi Vishnupriya; Shukla, Deepak Kumar; Kaur, Tanvir; Ali, Mohammed K; Mohan, Viswanathan
2011-01-01
Background Currently available estimates of diabetes prevalence in India are based on published data derived from very few studies. The Indian Council of Medical Research–India Diabetes (ICMR–INDIAB) study is a community-based survey conceived with the aim of obtaining the prevalence rates of diabetes in India as a whole, covering all 28 states, the National Capital Territory of Delhi, and two of the union territories in the mainland of India, with a total sample size of 124,000 individuals. Methods A stratified multistage sampling design has been used. In all study subjects, a structured questionnaire was administered and anthropometric parameters and blood pressure were measured. Fasting capillary blood glucose was first determined using a glucose meter. An oral glucose load was then administered to all subjects except those with self-reported diabetes, and the 2 h post-load capillary blood glucose was estimated. In every fifth subject, a fasting venous sample was collected for measurement of lipids and creatinine, a resting 12-lead electrocardiogram was performed, and dietary assessment questionnaire was administered. In all diabetic subjects, an additional diabetes questionnaire was used and a fasting venous sample drawn for glycated hemoglobin. Results All biological samples collected were analyzed in a central laboratory. All data collected were stored electronically. Quality control was achieved through multiple tiers of checks. Conclusions The ICMR–INDIAB study is the first of its kind attempting to provide accurate and comprehensive state- and national-level data on diabetes prevalence in India. PMID:21880233
Fithian, William; Elith, Jane; Hastie, Trevor; Keith, David A.
2016-01-01
Summary Presence-only records may provide data on the distributions of rare species, but commonly suffer from large, unknown biases due to their typically haphazard collection schemes. Presence–absence or count data collected in systematic, planned surveys are more reliable but typically less abundant.We proposed a probabilistic model to allow for joint analysis of presence-only and survey data to exploit their complementary strengths. Our method pools presence-only and presence–absence data for many species and maximizes a joint likelihood, simultaneously estimating and adjusting for the sampling bias affecting the presence-only data. By assuming that the sampling bias is the same for all species, we can borrow strength across species to efficiently estimate the bias and improve our inference from presence-only data.We evaluate our model’s performance on data for 36 eucalypt species in south-eastern Australia. We find that presence-only records exhibit a strong sampling bias towards the coast and towards Sydney, the largest city. Our data-pooling technique substantially improves the out-of-sample predictive performance of our model when the amount of available presence–absence data for a given species is scarceIf we have only presence-only data and no presence–absence data for a given species, but both types of data for several other species that suffer from the same spatial sampling bias, then our method can obtain an unbiased estimate of the first species’ geographic range. PMID:27840673
Report for the NGFA-5 project.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jaing, C; Jackson, P; Thissen, J
The objective of this project is to provide DHS a comprehensive evaluation of the current genomic technologies including genotyping, TaqMan PCR, multiple locus variable tandem repeat analysis (MLVA), microarray and high-throughput DNA sequencing in the analysis of biothreat agents from complex environmental samples. To effectively compare the sensitivity and specificity of the different genomic technologies, we used SNP TaqMan PCR, MLVA, microarray and high-throughput illumine and 454 sequencing to test various strains from B. anthracis, B. thuringiensis, BioWatch aerosol filter extracts or soil samples that were spiked with B. anthracis, and samples that were previously collected during DHS and EPAmore » environmental release exercises that were known to contain B. thuringiensis spores. The results of all the samples against the various assays are discussed in this report.« less
Ślączka-Wilk, Magdalena M; Włodarczyk, Elżbieta; Kaleniecka, Aleksandra; Zarzycki, Paweł K
2017-07-01
There is increasing interest in the development of simple analytical systems enabling the fast screening of target components in complex samples. A number of newly invented protocols are based on quasi separation techniques involving microfluidic paper-based analytical devices and/or micro total analysis systems. Under such conditions, the quantification of target components can be performed mainly due to selective detection. The main goal of this paper is to demonstrate that miniaturized planar chromatography has the capability to work as an efficient separation and quantification tool for the analysis of multiple targets within complex environmental samples isolated and concentrated using an optimized SPE method. In particular, we analyzed various samples collected from surface water ecosystems (lakes, rivers, and the Baltic Sea of Middle Pomerania in the northern part of Poland) in different seasons, as well as samples collected during key wastewater technological processes (originating from the "Jamno" wastewater treatment plant in Koszalin, Poland). We documented that the multiple detection of chromatographic spots on RP-18W microplates-under visible light, fluorescence, and fluorescence quenching conditions, and using the visualization reagent phosphomolybdic acid-enables fast and robust sample classification. The presented data reveal that the proposed micro-TLC system is useful, inexpensive, and can be considered as a complementary method for the fast control of treated sewage water discharged by a municipal wastewater treatment plant, particularly for the detection of low-molecular mass micropollutants with polarity ranging from estetrol to progesterone, as well as chlorophyll-related dyes. Due to the low consumption of mobile phases composed of water-alcohol binary mixtures (less than 1 mL/run for the simultaneous separation of up to nine samples), this method can be considered an environmentally friendly and green chemistry analytical tool. The described analytical protocol can be complementary to those involving classical column chromatography (HPLC) or various planar microfluidic devices.
Randall, M.T.; Sulak, K.J.
2012-01-01
Evidence of autumn spawning of Gulf sturgeon Acipenser oxyrinchus desotoi in the Suwannee River, Florida, was compiled from multiple investigations between 1986 and 2008. Gulf sturgeon are known from egg collections to spawn in the springtime months following immigration into rivers. Evidence of autumn spawning includes multiple captures of sturgeon in September through early November that were ripe (late-development ova; motile sperm) or exhibited just-spawned characteristics, telemetry of fish that made >175 river kilometer upstream excursions to the spawning grounds in September–October, and the capture of a 9.3 cm TL age-0 Gulf sturgeon on 29 November 2000 (which would have been spawned in late September 2000). Analysis of age-at-length data indicates that ca. 20% of the Suwannee River Gulf sturgeon population may be attributable to autumn spawning. However, with the very low sampling effort expended, eggs or early life stages have not yet been captured in the autumn, which would be the conclusive proof of autumn spawning. More sampling, and sampling at previously unknown sites frequented by acoustic telemetry fish, would be required to find eggs.
Modeling misidentification errors that result from use of genetic tags in capture-recapture studies
Yoshizaki, J.; Brownie, C.; Pollock, K.H.; Link, W.A.
2011-01-01
Misidentification of animals is potentially important when naturally existing features (natural tags) such as DNA fingerprints (genetic tags) are used to identify individual animals. For example, when misidentification leads to multiple identities being assigned to an animal, traditional estimators tend to overestimate population size. Accounting for misidentification in capture-recapture models requires detailed understanding of the mechanism. Using genetic tags as an example, we outline a framework for modeling the effect of misidentification in closed population studies when individual identification is based on natural tags that are consistent over time (non-evolving natural tags). We first assume a single sample is obtained per animal for each capture event, and then generalize to the case where multiple samples (such as hair or scat samples) are collected per animal per capture occasion. We introduce methods for estimating population size and, using a simulation study, we show that our new estimators perform well for cases with moderately high capture probabilities or high misidentification rates. In contrast, conventional estimators can seriously overestimate population size when errors due to misidentification are ignored. ?? 2009 Springer Science+Business Media, LLC.
Multiparallel Three-Dimensional Optical Microscopy
NASA Technical Reports Server (NTRS)
Nguyen, Lam K.; Price, Jeffrey H.; Kellner, Albert L.; Bravo-Zanoquera, Miguel
2010-01-01
Multiparallel three-dimensional optical microscopy is a method of forming an approximate three-dimensional image of a microscope sample as a collection of images from different depths through the sample. The imaging apparatus includes a single microscope plus an assembly of beam splitters and mirrors that divide the output of the microscope into multiple channels. An imaging array of photodetectors in each channel is located at a different distance along the optical path from the microscope, corresponding to a focal plane at a different depth within the sample. The optical path leading to each photodetector array also includes lenses to compensate for the variation of magnification with distance so that the images ultimately formed on all the photodetector arrays are of the same magnification. The use of optical components common to multiple channels in a simple geometry makes it possible to obtain high light-transmission efficiency with an optically and mechanically simple assembly. In addition, because images can be read out simultaneously from all the photodetector arrays, the apparatus can support three-dimensional imaging at a high scanning rate.
Search for neutrinoless double-electron capture of 156Dy
NASA Astrophysics Data System (ADS)
Finch, S. W.; Tornow, W.
2015-12-01
Background: Multiple large collaborations are currently searching for neutrinoless double-β decay, with the ultimate goal of differentiating the Majorana-Dirac nature of the neutrino. Purpose: Investigate the feasibility of resonant neutrinoless double-electron capture, an experimental alternative to neutrinoless double-β decay. Method: Two clover germanium detectors were operated underground in coincidence to search for the de-excitation γ rays of 156Gd following the neutrinoless double-electron capture of 156Dy. 231.95 d of data were collected at the Kimballton underground research facility with a 231.57 mg enriched 156Dy sample. Results: No counts were seen above background and half-life limits are set at O (1016-1018) yr for the various decay modes of 156Dy. Conclusion: Low background spectra were efficiently collected in the search for neutrinoless double-electron capture of 156Dy, although the low natural abundance and associated lack of large quantities of enriched samples hinders the experimental reach.
Madigan, Sheri; Wade, Mark; Plamondon, André; Jenkins, Jennifer M
2016-06-01
In a socio-demographically diverse sample of 501 caregivers participating in a longitudinal birth cohort study during the childbearing years, we examined whether neighborhood collective efficacy moderated the association between maternal adverse childhood experience (ACEs) and marital conflict. Maternal ACEs were assessed via retrospective reports. Neighborhood collective efficacy was measured via maternal and paternal reports at 2 months, and maternal reports of marital conflict were collected at infant age 2 and 18 months. Multiple linear regression analyses revealed that maternal ACEs were associated with increased marital conflict. Neighborhood collective efficacy moderated the association between early maternal ACEs and marital conflict, such that mothers experiencing ACEs had lower levels of marital conflict when exposed to high levels of neighborhood collective efficacy. Results suggest that extra-familial sources of social support and control, such as feelings of security, trust, order, and connectedness with others, may buffer the effects of early adversity on marital discord. © Society for Community Research and Action 2016.
Organizational Commitment and Nurses' Characteristics as Predictors of Job Involvement.
Alammar, Kamila; Alamrani, Mashael; Alqahtani, Sara; Ahmad, Muayyad
2016-01-01
To predict nurses' job involvement on the basis of their organizational commitment and personal characteristics at a large tertiary hospital in Saudi Arabia. Data were collected in 2015 from a convenience sample of 558 nurses working at a large tertiary hospital in Riyadh, Saudi Arabia. A cross-sectional correlational design was used in this study. Data were collected using a structured questionnaire. All commitment scales had significant relationships. Multiple linear regression analysis revealed that the model predicted a sizeable proportion of variance in nurses' job involvement (p < 0.001). High organizational commitment enhances job involvement, which may lead to more organizational stability and effectiveness.
2014-01-01
Background Chiari Type I Malformation (CMI) is characterized by herniation of the cerebellar tonsils through the foramen magnum at the base of the skull, resulting in significant neurologic morbidity. As CMI patients display a high degree of clinical variability and multiple mechanisms have been proposed for tonsillar herniation, it is hypothesized that this heterogeneous disorder is due to multiple genetic and environmental factors. The purpose of the present study was to gain a better understanding of what factors contribute to this heterogeneity by using an unsupervised statistical approach to define disease subtypes within a case-only pediatric population. Methods A collection of forty-four pediatric CMI patients were ascertained to identify disease subtypes using whole genome expression profiles generated from patient blood and dura mater tissue samples, and radiological data consisting of posterior fossa (PF) morphometrics. Sparse k-means clustering and an extension to accommodate multiple data sources were used to cluster patients into more homogeneous groups using biological and radiological data both individually and collectively. Results All clustering analyses resulted in the significant identification of patient classes, with the pure biological classes derived from patient blood and dura mater samples demonstrating the strongest evidence. Those patient classes were further characterized by identifying enriched biological pathways, as well as correlated cranial base morphological and clinical traits. Conclusions Our results implicate several strong biological candidates warranting further investigation from the dura expression analysis and also identified a blood gene expression profile corresponding to a global down-regulation in protein synthesis. PMID:24962150
Okello, James; Nakimuli-Mpungu, Etheldreda; Musisi, Seggane; Broekaert, Eric; Derluyn, Ilse
2013-11-01
The relationship between war-related trauma exposure, depressive symptoms and multiple risk behaviors among adolescents is less clear in sub-Saharan Africa. We analyzed data collected from a sample of school-going adolescents four years postwar. Participants completed interviews assessing various risk behaviors defined by the Youth Self Report (YSR) and a sexual risk behavior survey, and were screened for post-traumatic stress, anxiety and depression symptoms based on the Impact of Events Scale Revised (IESR) and Hopkins Symptom Checklist for Adolescents (HSCL-37A) respectively. Multivariate logistic regression was used to assess factors independently associated with multiple risk behaviors. The logistic regression model of Baron and Kenny (1986) was used to evaluate the mediating role of depression in the relationship between stressful war events and multiple risk behaviors. Of 551 participants, 139 (25%) reported multiple (three or more) risk behaviors in the past year. In the multivariate analyses, depression symptoms remained uniquely associated with multiple risk behavior after adjusting for potential confounders including socio-demographic characteristics, war-related trauma exposure variables, anxiety and post-traumatic stress symptoms. In mediation analysis, depression symptoms mediated the associations between stressful war events and multiple risk behaviors. The psychometric properties of the questionnaires used in this study are not well established in war affected African samples thus ethno cultural variation may decrease the validity of our measures. Adolescents with depression may be at a greater risk of increased engagement in multiple risk behaviors. Culturally sensitive and integrated interventions to treat and prevent depression among adolescents in post-conflict settings are urgently needed. © 2013 Elsevier B.V. All rights reserved.
Preserving Geological Samples and Metadata from Polar Regions
NASA Astrophysics Data System (ADS)
Grunow, A.; Sjunneskog, C. M.
2011-12-01
The Office of Polar Programs at the National Science Foundation (NSF-OPP) has long recognized the value of preserving earth science collections due to the inherent logistical challenges and financial costs of collecting geological samples from Polar Regions. NSF-OPP established two national facilities to make Antarctic geological samples and drill cores openly and freely available for research. The Antarctic Marine Geology Research Facility (AMGRF) at Florida State University was established in 1963 and archives Antarctic marine sediment cores, dredge samples and smear slides along with ship logs. The United States Polar Rock Repository (USPRR) at Ohio State University was established in 2003 and archives polar rock samples, marine dredges, unconsolidated materials and terrestrial cores, along with associated materials such as field notes, maps, raw analytical data, paleomagnetic cores, thin sections, microfossil mounts, microslides and residues. The existence of the AMGRF and USPRR helps to minimize redundant sample collecting, lessen the environmental impact of doing polar field work, facilitates field logistics planning and complies with the data sharing requirement of the Antarctic Treaty. USPRR acquires collections through donations from institutions and scientists and then makes these samples available as no-cost loans for research, education and museum exhibits. The AMGRF acquires sediment cores from US based and international collaboration drilling projects in Antarctica. Destructive research techniques are allowed on the loaned samples and loan requests are accepted from any accredited scientific institution in the world. Currently, the USPRR has more than 22,000 cataloged rock samples available to scientists from around the world. All cataloged samples are relabeled with a USPRR number, weighed, photographed and measured for magnetic susceptibility. Many aspects of the sample metadata are included in the database, e.g. geographical location, sample description, collector, rock age, formation, section location, multimedia images as well structural data, field observations, logistics, surface features, etc. The metadata are entered into a commercial, museum based database called EMu. The AMGRF houses more than 25,000m of deep-sea cores and drill cores as well as nearly 3,000 meters of rotary cored geological material from Antarctica. Detailed information on the sediment cores including location, sediment composition are available in cruise reports posted on the AMGRF web-site. Researchers may access the sample collections through the online websites (http://www-bprc.mps.ohio-state.edu/emuwebusprr and http://www.arf.fsu.edu). Searches may be done using multiple search terms or by use of the mapping feature. The on-line databases provide an essential resource for proposal preparation, pilot studies and other sample based research that should make fieldwork more efficient.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hill, T M; Spero, H J; Guilderson, T P
Deep-sea bamboo corals hold promise as long-term climatic archives, yet little information exists linking bamboo coral geochemistry to measured environmental parameters. This study focuses on a suite of 10 bamboo corals collected from the Pacific and Atlantic basins (250-2136 m water depth) to investigate coral longevity, growth rates, and isotopic signatures. Calcite samples for stable isotopes and radiocarbon were collected from the base the corals, where the entire history of growth is recorded. In three of the coral specimens, samples were also taken from an upper branch for comparison. Radiocarbon and growth band width analyses indicate that the skeletal calcitemore » precipitates from ambient dissolved inorganic carbon and that the corals live for 150-300 years, with extension rates of 9-128 {micro}m/yr. A linear relationship between coral calcite {delta}{sup 18}O and {delta}{sup 13}C indicates that the isotopic composition is influenced by vital effects ({delta}{sup 18}O:{delta}{sup 13}C slope of 0.17-0.47). As with scleractinian deep-sea corals, the intercept from a linear regression of {delta}{sup 18}O versus {delta}{sup 13}C is a function of temperature, such that a reliable paleotemperature proxy can be obtained, using the 'lines method.' Although the coral calcite {delta}{sup 18}O:{delta}{sup 13}C slope is maintained throughout the coral base ontogeny, the branches and central cores of the bases exhibit {delta}{sup 18}O:{delta}{sup 13}C values that are shifted far from equilibrium. We find that a reliable intercept value can be derived from the {delta}{sup 18}O:{delta}{sup 13}C regression of multiple samples distributed throughout one specimen or from multiple samples within individual growth bands.« less
NASA Biological Specimen Repository
NASA Technical Reports Server (NTRS)
Pietrzyk, Robert; McMonigal, K. A.; Sams, C. F.; Johnson, M. A.
2009-01-01
The NASA Biological Specimen Repository (NBSR) has been established to collect, process, annotate, store, and distribute specimens under the authority of the NASA/JSC Committee for the Protection of Human Subjects. The International Space Station (ISS) provides a platform to investigate the effects of microgravity on human physiology prior to lunar and exploration class missions. The NBSR is a secure controlled storage facility that is used to maintain biological specimens over extended periods of time, under well-controlled conditions, for future use in approved human spaceflight-related research protocols. The repository supports the Human Research Program, which is charged with identifying and investigating physiological changes that occur during human spaceflight, and developing and implementing effective countermeasures when necessary. The storage of crewmember samples from many different ISS flights in a single repository will be a valuable resource with which researchers can validate clinical hypotheses, study space-flight related changes, and investigate physiological markers All samples collected require written informed consent from each long duration crewmember. The NBSR collects blood and urine samples from all participating long duration ISS crewmembers. These biological samples are collected pre-flight at approximately 45 days prior to launch, during flight on flight days 15, 30, 60 120 and within 2 weeks of landing. Postflight sessions are conducted 3 and 30 days following landing. The number of inflight sessions is dependent on the duration of the mission. Operations began in 2007 and as of October 2009, 23 USOS crewmembers have completed or agreed to participate in this project. As currently planned, these human biological samples will be collected from crewmembers covering multiple ISS missions until the end of U.S. presence on the ISS or 2017. The NBSR will establish guidelines for sample distribution that are consistent with ethical principles, protection of crewmember confidentiality, prevailing laws and regulations, intellectual property policies, and consent form language. A NBSR Advisory Board composed of representatives of all participating agencies will be established to evaluate each request by an investigator for use of the samples to ensure the request reflects the mission of the NBSR.
NASA Astrophysics Data System (ADS)
Ramdeen, S.; Hangsterfer, A.; Stanley, V. L.
2017-12-01
There is growing enthusiasm for curation of physical samples in the Earth Science community (see sessions at AGU, GSA, ESIP). Multiple federally funded efforts aim to develop best practices for curation of physical samples; however, these efforts have not yet been consolidated. Harmonizing these concurrent efforts would enable the community as a whole to build the necessary tools and community standards to move forward together. Preliminary research indicate the various groups focused on this topic are working in isolation, and the development of standards needs to come from the broadest view of `community'. We will investigate the gaps between communities by collecting information about preservation policies and practices from curators, who can provide a diverse cross-section of the grand challenges to the overall community. We will look at existing reports and study results to identify example cases, then develop a survey to gather large scale data to reinforce or clarify the example cases. We will be targeting the various community groups which are working on similar issues, and use the survey to improve the visibility of developed best practices. Given that preservation and digital collection management for physical samples are both important and difficult at present (GMRWG, 2015; NRC, 2002), barriers to both need to be addressed in order to achieve open science goals for the entire community. To address these challenges, EarthCube's iSamples, a research coordination network established to advance discoverability, access, and curation of physical samples using cyberinfrastructure, has formed a working group to collect use cases to examine the breadth of earth scientists' work with physical samples. This research team includes curators of state survey and oceanographic geological collections, and a researcher from information science. In our presentation, we will share our research and the design of the proposed survey. Our goal is to engage the audience in a discussion on next steps towards building this community. References: The Geologic Materials Repository Working Group, 2015, USGS Circular 1410 National Research Council. 2002. Geoscience Data and Collections: National Resources in Peril.
Y(nS) polarizations versus particle multiplicity in pp collisions at s = 7 TeV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khachatryan, Vardan
The polarizations of the Y(1S), Y(2S), and Y(3S) mesons are measured as a function of the charged particle multiplicity in proton-proton collisions at √s = 7 TeV. The measurements are performed with a dimuon data sample collected in 2011 by the CMS experiment, corresponding to an integrated luminosity of 4.9 fb –1. The results are extracted from the dimuon decay angular distributions, in two ranges of Y(nS) transverse momentum (10-15 and 15-35 GeV), and in the rapidity interval |y| < 1.2. Furthermore, the results do not show significant changes from low- to high-multiplicity pp collisions, although large uncertainties preclude definitemore » statements in the Y(2S) and Y(3S) cases.« less
An integrated and accessible sample data library for Mars sample return science
NASA Astrophysics Data System (ADS)
Tuite, M. L., Jr.; Williford, K. H.
2015-12-01
Over the course of the next decade or more, many thousands of geological samples will be collected and analyzed in a variety of ways by researchers at the Jet Propulsion Laboratory (California Institute of Technology) in order to facilitate discovery and contextualize observations made of Mars rocks both in situ and here on Earth if samples are eventually returned. Integration of data from multiple analyses of samples including petrography, thin section and SEM imaging, isotope and organic geochemistry, XRF, XRD, and Raman spectrometry is a challenge and a potential obstacle to discoveries that require supporting lines of evidence. We report the development of a web-accessible repository, the Sample Data Library (SDL) for the sample-based data that are generated by the laboratories and instruments that comprise JPL's Center for Analysis of Returned Samples (CARS) in order to facilitate collaborative interpretation of potential biosignatures in Mars-analog geological samples. The SDL is constructed using low-cost, open-standards-based Amazon Web Services (AWS), including web-accessible storage, relational data base services, and a virtual web server. The data structure is sample-centered with a shared registry for assigning unique identifiers to all samples including International Geo-Sample Numbers. Both raw and derived data produced by instruments and post-processing workflows are automatically uploaded to online storage and linked via the unique identifiers. Through the web interface, users are able to find all the analyses associated with a single sample or search across features shared by multiple samples, sample localities, and analysis types. Planned features include more sophisticated search and analytical interfaces as well as data discoverability through NSF's EarthCube program.
Case Study: An Ethics Case Study of HIV Prevention Research on Facebook: The Just/Us Study
Breslin, Lindsey T.; Wright, Erin E.; Black, Sandra R.; Levine, Deborah; Santelli, John S.
2011-01-01
Objective To consider issues related to research with youth on social networking sites online. Methods Description of the data collection process from 1,588 participants in a randomized controlled trial testing the efficacy of HIV prevention education delivered on Facebook. Using respondent-driven sampling, staff-recruited participants are encouraged to recruit up to three friends to enroll in the study. Results Researchers should (a) consider whether an online social networking site is an appropriate place to implement a research study; (b) offer opportunities to review informed consent documents at multiple times and in multiple locations throughout the study; and (c) collect data outside the social networking site and store it behind secure firewalls to ensure it will not be accessible to any person on the social networking site. Conclusions Online social networks are growing in popularity. Conducting research on social media sites requires deliberate attention to consent, confidentiality, and security. PMID:21292724
Trace organic compounds in wet atmospheric deposition: an overview
Steinheimer, T.R.; Johnson, S.M.
1987-01-01
An overview of the occurrence of organic compounds in wet atmospheric deposition is given. Multiplicity of sources and problems associated with source identification are discussed. Available literature is reviewed by using citations from Chemical Abstracts and Water Resources Abstracts through June 1985 and includes reports published through December 1984 that summarize current knowledge. Approaches to the chemical determination of organic compounds in precipitation are examined in addition to aspects of sampling protocols. Best methods for sample collection and preparation for instrumental analysis continue to be discussed among various investigators. Automatic wet-deposition-only devices for collection and extraction are preferred. Classes of organic compounds that have been identified in precipitation include a spectrum of compounds with differing properties of acidity or basicity, polarity, and water solubility. Those compounds that have been reported in rainfall, snowfall, and ice include hydrocarbons (both aromatic and nonaromatic), chlorinated derivatives of these hydrocarbons, carbonyl compounds (both acidic and nonacidic), and carboxylic acids and esters. Formic and acetic are the most abundant organic acids present. Cloudwater, fogwater, and mist also have been collected and analyzed for organic composition.
Coggins, Lewis G; Bacheler, Nathan M; Gwinn, Daniel C
2014-01-01
Occupancy models using incidence data collected repeatedly at sites across the range of a population are increasingly employed to infer patterns and processes influencing population distribution and dynamics. While such work is common in terrestrial systems, fewer examples exist in marine applications. This disparity likely exists because the replicate samples required by these models to account for imperfect detection are often impractical to obtain when surveying aquatic organisms, particularly fishes. We employ simultaneous sampling using fish traps and novel underwater camera observations to generate the requisite replicate samples for occupancy models of red snapper, a reef fish species. Since the replicate samples are collected simultaneously by multiple sampling devices, many typical problems encountered when obtaining replicate observations are avoided. Our results suggest that augmenting traditional fish trap sampling with camera observations not only doubled the probability of detecting red snapper in reef habitats off the Southeast coast of the United States, but supplied the necessary observations to infer factors influencing population distribution and abundance while accounting for imperfect detection. We found that detection probabilities tended to be higher for camera traps than traditional fish traps. Furthermore, camera trap detections were influenced by the current direction and turbidity of the water, indicating that collecting data on these variables is important for future monitoring. These models indicate that the distribution and abundance of this species is more heavily influenced by latitude and depth than by micro-scale reef characteristics lending credence to previous characterizations of red snapper as a reef habitat generalist. This study demonstrates the utility of simultaneous sampling devices, including camera traps, in aquatic environments to inform occupancy models and account for imperfect detection when describing factors influencing fish population distribution and dynamics.
Coggins, Lewis G.; Bacheler, Nathan M.; Gwinn, Daniel C.
2014-01-01
Occupancy models using incidence data collected repeatedly at sites across the range of a population are increasingly employed to infer patterns and processes influencing population distribution and dynamics. While such work is common in terrestrial systems, fewer examples exist in marine applications. This disparity likely exists because the replicate samples required by these models to account for imperfect detection are often impractical to obtain when surveying aquatic organisms, particularly fishes. We employ simultaneous sampling using fish traps and novel underwater camera observations to generate the requisite replicate samples for occupancy models of red snapper, a reef fish species. Since the replicate samples are collected simultaneously by multiple sampling devices, many typical problems encountered when obtaining replicate observations are avoided. Our results suggest that augmenting traditional fish trap sampling with camera observations not only doubled the probability of detecting red snapper in reef habitats off the Southeast coast of the United States, but supplied the necessary observations to infer factors influencing population distribution and abundance while accounting for imperfect detection. We found that detection probabilities tended to be higher for camera traps than traditional fish traps. Furthermore, camera trap detections were influenced by the current direction and turbidity of the water, indicating that collecting data on these variables is important for future monitoring. These models indicate that the distribution and abundance of this species is more heavily influenced by latitude and depth than by micro-scale reef characteristics lending credence to previous characterizations of red snapper as a reef habitat generalist. This study demonstrates the utility of simultaneous sampling devices, including camera traps, in aquatic environments to inform occupancy models and account for imperfect detection when describing factors influencing fish population distribution and dynamics. PMID:25255325
Decision-theoretic approach to data acquisition for transit operations planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ritchie, S.G.
The most costly element of transportation planning and modeling activities in the past has usually been that of data acquisition. This is even truer today when the unit costs of data collection are increasing rapidly and at the same time budgets are severely limited by continuing policies of fiscal austerity in the public sector. The overall objectives of this research were to improve the decisions and decision-making capabilities of transit operators or planners in short-range transit planning, and to improve the quality and cost-effectiveness of associated route or corridor-level data collection and service monitoring activities. A new approach was presentedmore » for sequentially updating the parameters of both simple and multiple linear regression models with stochastic regressors, and for determining the expected value of sample information and expected net gain of sampling for associated sample designs. A new approach was also presented for estimating and updating (both spatially and temporally) the parameters of multinomial logit discrete choice models, and for determining associated optimal sample designs for attribute-based and choice-based sampling methods. The approach provides an effective framework for addressing the issue of optimal sampling method and sample size, which to date have been largely unresolved. The application of these methodologies and the feasibility of the decision-theoretic approach was illustrated with a hypothetical case study example.« less
NASA Astrophysics Data System (ADS)
Hus, Jean-Christophe; Bruschweiler, Rafael
2002-07-01
A general method is presented for the reconstruction of interatomic vector orientations from nuclear magnetic resonance (NMR) spectroscopic data of tensor interactions of rank 2, such as dipolar coupling and chemical shielding anisotropy interactions, in solids and partially aligned liquid-state systems. The method, called PRIMA, is based on a principal component analysis of the covariance matrix of the NMR parameters collected for multiple alignments. The five nonzero eigenvalues and their eigenvectors efficiently allow the approximate reconstruction of the vector orientations of the underlying interactions. The method is demonstrated for an isotropic distribution of sample orientations as well as for finite sets of orientations and internuclear vectors encountered in protein systems.
Taly, Valerie; Pekin, Deniz; Benhaim, Leonor; Kotsopoulos, Steve K; Le Corre, Delphine; Li, Xinyu; Atochin, Ivan; Link, Darren R; Griffiths, Andrew D; Pallier, Karine; Blons, Hélène; Bouché, Olivier; Landi, Bruno; Hutchison, J Brian; Laurent-Puig, Pierre
2013-12-01
Multiplex digital PCR (dPCR) enables noninvasive and sensitive detection of circulating tumor DNA with performance unachievable by current molecular-detection approaches. Furthermore, picodroplet dPCR facilitates simultaneous screening for multiple mutations from the same sample. We investigated the utility of multiplex dPCR to screen for the 7 most common mutations in codons 12 and 13 of the KRAS (Kirsten rat sarcoma viral oncogene homolog) oncogene from plasma samples of patients with metastatic colorectal cancer. Fifty plasma samples were tested from patients for whom the primary tumor biopsy tissue DNA had been characterized by quantitative PCR. Tumor characterization revealed that 19 patient tumors had KRAS mutations. Multiplex dPCR analysis of the plasma DNA prepared from these samples identified 14 samples that matched the mutation identified in the tumor, 1 sample contained a different KRAS mutation, and 4 samples had no detectable mutation. Among the tumor samples that were wild type for KRAS, 2 KRAS mutations were identified in the corresponding plasma samples. Duplex dPCR (i.e., wild-type and single-mutation assay) was also used to analyze plasma samples from patients with KRAS-mutated tumors and 5 samples expected to contain the BRAF (v-raf murine sarcoma viral oncogene homolog B) V600E mutation. The results for the duplex analysis matched those for the multiplex analysis for KRAS-mutated samples and, owing to its higher sensitivity, enabled detection of 2 additional samples with low levels of KRAS-mutated DNA. All 5 samples with BRAF mutations were detected. This work demonstrates the clinical utility of multiplex dPCR to screen for multiple mutations simultaneously with a sensitivity sufficient to detect mutations in circulating DNA obtained by noninvasive blood collection.
A round robin approach to the analysis of bisphenol a (BPA) in human blood samples
2014-01-01
Background Human exposure to bisphenol A (BPA) is ubiquitous, yet there are concerns about whether BPA can be measured in human blood. This Round Robin was designed to address this concern through three goals: 1) to identify collection materials, reagents and detection apparatuses that do not contribute BPA to serum; 2) to identify sensitive and precise methods to accurately measure unconjugated BPA (uBPA) and BPA-glucuronide (BPA-G), a metabolite, in serum; and 3) to evaluate whether inadvertent hydrolysis of BPA-G occurs during sample handling and processing. Methods Four laboratories participated in this Round Robin. Laboratories screened materials to identify BPA contamination in collection and analysis materials. Serum was spiked with concentrations of uBPA and/or BPA-G ranging from 0.09-19.5 (uBPA) and 0.5-32 (BPA-G) ng/mL. Additional samples were preserved unspiked as ‘environmental’ samples. Blinded samples were provided to laboratories that used LC/MSMS to simultaneously quantify uBPA and BPA-G. To determine whether inadvertent hydrolysis of BPA metabolites occurred, samples spiked with only BPA-G were analyzed for the presence of uBPA. Finally, three laboratories compared direct and indirect methods of quantifying BPA-G. Results We identified collection materials and reagents that did not introduce BPA contamination. In the blinded spiked sample analysis, all laboratories were able to distinguish low from high values of uBPA and BPA-G, for the whole spiked sample range and for those samples spiked with the three lowest concentrations (0.5-3.1 ng/ml). By completion of the Round Robin, three laboratories had verified methods for the analysis of uBPA and two verified for the analysis of BPA-G (verification determined by: 4 of 5 samples within 20% of spiked concentrations). In the analysis of BPA-G only spiked samples, all laboratories reported BPA-G was the majority of BPA detected (92.2 – 100%). Finally, laboratories were more likely to be verified using direct methods than indirect ones using enzymatic hydrolysis. Conclusions Sensitive and accurate methods for the direct quantification of uBPA and BPA-G were developed in multiple laboratories and can be used for the analysis of human serum samples. BPA contamination can be controlled during sample collection and inadvertent hydrolysis of BPA conjugates can be avoided during sample handling. PMID:24690217
Drivers of microbiological quality of household drinking water - a case study in rural Ethiopia.
Usman, Muhammed A; Gerber, Nicolas; Pangaribowo, Evita H
2018-04-01
This study aims at assessing the determinants of microbiological contamination of household drinking water under multiple-use water systems in rural areas of Ethiopia. For this analysis, a random sample of 454 households was surveyed between February and March 2014, and water samples from community sources and household storage containers were collected and tested for fecal contamination. The number of Escherichia coli (E. coli) colony-forming units per 100 mL water was used as an indicator of fecal contamination. The microbiological tests demonstrated that 58% of household stored water samples and 38% of protected community water sources were contaminated with E. coli. Moreover, most improved water sources often considered to provide safe water showed the presence of E. coli. The result shows that households' stored water collected from unprotected wells/springs had higher levels of E. coli than stored water from alternative sources. Distance to water sources and water collection containers are also strongly associated with stored water quality. To ensure the quality of stored water, the study suggests that there is a need to promote water safety from the point-of-source to point-of-use, with due considerations for the linkages between water and agriculture to advance the Sustainable Development Goal 6 of ensuring access to clean water for everyone.
Two Stellar Components in the Halo of the Milky Way
2007-12-13
that might be considered, multiple lines of evidence derived from these data clearly confirm that the halo can be resolved into (at least) two primary...of the inner-halo population. Evidence for the dichotomy of the halo The spectroscopy, photometry and astrometry for our large sample of stars were...0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing
Zappia, Humbert
2002-01-01
During the summer of 1998, as part of the National Water-Quality Assessment Program, a survey was conducted to determine which organochlorine compounds and trace elements occur in fish tissues and streambed sediments in the Mobile River Basin, which includes parts of Alabama, Mississippi, Georgia, and Tennessee. The data collected were compared to guidelines related to wildlife, land use, and to 1991 and 1994 National Water-Quality Assessment Program Study-Unit data.Twenty-one sites were sampled in subbasins of the Mobile River Basin. The subbasins ranged in size from about 9 to 22,000 square miles and were dominated by either a single land use or a combination of land uses. The major land-use categories were urban, agriculture, and forest.Organochlorine compounds were widespread spatially in the Mobile River Basin. At least one organochlorine compound was reported at the majority of sampling sites (84 percent) and in a majority of whole-fish (80 percent) and streambed-sediment (52 percent) samples. Multiple organochlorine compounds were reported at 75 percent of the sites where fish tissues were collected and were reported at many of the streambed-sediment sampling sites (45 percent). The majority of concentrations reported, however, were less than 5 micrograms per kilogram in fish-tissue samples and less than 1 microgram per kilogram in streambed-sediment samples.The majority of trace elements analyzed in fish-liver tissue (86 percent) and streambed-sediment (98 percent) samples were reported during this study. Multiple trace elements were reported in all samples and at all sites.Based on comparisons of concentrations of organochlorine compounds and trace elements in fish-tissue and streambed-sediment samples in relation to National Academy of Science and National Academy of Engineering and Canadian tissue guidelines, probable-effects concentrations, and mean probable-effects concentration quotients for streambed sediment, the potential exists for adverse effects to wildlife at 15 (72 percent) of the sites sampled. The potential for adverse effects at these sites is because of the presence of residues or breakdown products related to polychlorinated biphenyls (PCB?s), chlordane, dichlorodiphenyltrichloroethane (DDT), chromium, lead, and zinc.The majority of compounds reported (65 percent) were chlordane, DDT, and PCB?s, or their breakdown products. Concentrations of chlordane and heptachlor epoxide in whole-fish tissue were positively correlated to the amount of urban land use in a basin. Total DDT concentrations in whole-fish tissues were positively correlated to agriculture.The relation of trace elements to land use is not as clear as the relation of organochlorine compounds to land use. This lack of clarity may be due to the possibility of geologic sources of trace elements in the Mobile River Basin and to the ubiquitous nature of many of these trace elements. However, there may be a correlation between the amount of urban land use and concentrations of antimony, cadmium, lead, and zinc in streambed-sediment samples from the Mobile River Basin.Fewer organochlorine compounds and trace elements were reported in samples from the Mobile River Basin than in samples collected during the 1991 and 1994 National Water-Quality Assessment Program studies. Of the organochlorine compounds analyzed nationally, 57 percent were reported in whole-fish tissue samples collected locally and 41 percent were reported in streambed-sediment samples collected locally, whereas 96 percent and 86 percent, respectively, were reported nationally. Of trace elements analyzed nationally, 86 percent were reported in fish-liver tissue locally and 95 percent were reported in streambed-sediment samples locally, whereas 95 percent and 98 percent, respectively, were reported nationally.In general, concentrations of organochlorine compounds and trace elements and the frequency with which they were reported in the Mobile River Basin are similar to or less than t
Radin, Joanna
2014-09-01
In the decades after World War II, the World Health Organization (WHO) played an important role in managing the process of stabilizing collections of variable blood samples as a fundamentally unstable, protean, and unfolding biomedical resource. In this system, known and as yet unknown constituents of blood were positioned as relevant to the work of multiple constituencies including human population geneticists, physical anthropologists, and immunologists. To facilitate serving these and other constituencies, it was crucial to standardize practices of collecting and preserving samples of blood from globally distributed human populations. The WHO achieved this by linking its administrative infrastructure-comprised of expert advisory groups and technical reports-to key laboratories, which served as sites for demonstrating and also for disseminating standards for working with variable blood samples. The practices that were articulated in making blood samples into a flexible resource contributes to emerging histories of global health that highlight the centrality of new institutions, like the WHO, new forms of expertise, like population genetics and serological epidemiology, and new kinds of research materials, like frozen blood. Copyright © 2014 Elsevier Ltd. All rights reserved.
Mellert, Hestia S.; Alexander, Kristin E.; Jackson, Leisa P.; Pestano, Gary A.
2018-01-01
We have developed novel methods for the isolation and characterization of tumor-derived circulating ribonucleic acid (cRNA) for blood-based liquid biopsy. Robust detection of cRNA recovered from blood represents a solution to a critical unmet need in clinical diagnostics. The test begins with the collection of whole blood into blood collection tubes containing preservatives that stabilize cRNA. Cell-free, exosomal, and platelet-associated RNA is isolated from plasma in this test system. The cRNA is reverse transcribed to complementary DNA (cDNA) and amplified using digital polymerase chain reaction (dPCR). Samples are evaluated for both the target biomarker as well as a control gene. Test validation included limit of detection, accuracy, and robustness studies with analytic samples. The method developed as a result of these studies reproducibly detect multiple fusion variants for ROS1 (C-Ros proto-oncogene 1; 8 variants) and RET (rearranged during transfection proto-oncogene; 8 variants). The sample processing workflow has been optimized so that test results can consistently be generated within 72 hours of sample receipt. PMID:29683453
What measurements tell us about air composition and emissions in three US oil and gas fields
NASA Astrophysics Data System (ADS)
Petron, G.; Miller, B. R.; Montzka, S. A.; Dlugokencky, E. J.; Kofler, J.; Sweeney, C.; Karion, A.; Frost, G. J.; Helmig, D.; Hueber, J.; Schnell, R. C.; Conley, S. A.; Tans, P. P.
2013-12-01
In 2012 and 2013, the NOAA Global Monitoring Division and several collaborators conducted intensive airborne and ground campaigns in three US oil and gas plays to study emissions of methane and surface ozone precursors. In this presentation we will focus on the multiple species analysis in discrete air samples collected with the NOAA Mobile Laboratory (ML) and the light aircraft in the Uinta Basin (Utah), Denver Julesburg Basin (Colorado) and Barnett Shale (Texas). Hydrocarbon ratios in samples collected with the ML downwind of specific sources show significantly more variability than the aircraft samples. These surface samples provide some useful information about the composition of various sources in each region. Ratios of the non-methane hydrocarbons on the ground and higher in the boundary layer show some differences between the plays, which could be explained by the different composition of the raw gas being produced or by different mixes of sources contributions. Understanding the speciation of atmospheric emissions is critical to identify emission vectors and to assess their potential air quality and climate impacts. Our measurement results will be compared with data from other studies, including emission inventories.
Current Knowledge on Cannabinoids in Oral Fluid
Lee, Dayong; Huestis, Marilyn A.
2015-01-01
Oral fluid (OF) is a new biological matrix for clinical and forensic drug testing, offering non-invasive and directly observable sample collection reducing adulteration potential, ease of multiple sample collections, lower biohazard risk during collection, recent exposure identification, and stronger correlation with blood than urine concentrations. Because cannabinoids are usually the most prevalent analytes in illicit drug testing, application of OF drug testing requires sufficient scientific data to support sensitive and specific OF cannabinoid detection. This review presents current knowledge on OF cannabinoids, evaluating pharmacokinetic properties, detection windows, and correlation with other biological matrices and impairment from field applications and controlled drug administration studies. In addition, on-site screening technologies, confirmatory analytical methods, drug stability, and effects of sample collection procedure, adulterants, and passive environmental exposure are reviewed. Delta-9-tetrahydrocannabinol OF concentrations could be > 1000 μg/L shortly after smoking, whereas minor cannabinoids are detected at 10-fold and metabolites at 1000-fold lower concentrations. OF research over the past decade demonstrated that appropriate interpretation of test results requires a comprehensive understanding of distinct elimination profiles and detection windows for different cannabinoids, which are influenced by administration route, dose, and drug use history. Thus, each drug testing program should establish cutoff criteria, collection/analysis procedures, and storage conditions tailored to its purposes. Building a scientific basis for OF testing is on-going, with continuing OF cannabinoids research on passive environmental exposure, drug use history, donor physiological conditions, and oral cavity metabolism needed to better understand mechanisms of cannabinoid OF disposition and expand OF drug testing applicability. PMID:23983217
NASA Astrophysics Data System (ADS)
Vilhelmsen, Troels N.; Ferré, Ty P. A.
2016-04-01
Hydrological models are often developed to forecasting future behavior in response due to natural or human induced changes in stresses affecting hydrologic systems. Commonly, these models are conceptualized and calibrated based on existing data/information about the hydrological conditions. However, most hydrologic systems lack sufficient data to constrain models with adequate certainty to support robust decision making. Therefore, a key element of a hydrologic study is the selection of additional data to improve model performance. Given the nature of hydrologic investigations, it is not practical to select data sequentially, i.e. to choose the next observation, collect it, refine the model, and then repeat the process. Rather, for timing and financial reasons, measurement campaigns include multiple wells or sampling points. There is a growing body of literature aimed at defining the expected data worth based on existing models. However, these are almost all limited to identifying single additional observations. In this study, we present a methodology for simultaneously selecting multiple potential new observations based on their expected ability to reduce the uncertainty of the forecasts of interest. This methodology is based on linear estimates of the predictive uncertainty, and it can be used to determine the optimal combinations of measurements (location and number) established to reduce the uncertainty of multiple predictions. The outcome of the analysis is an estimate of the optimal sampling locations; the optimal number of samples; as well as a probability map showing the locations within the investigated area that are most likely to provide useful information about the forecasting of interest.
Circum-Arctic petroleum systems identified using decision-tree chemometrics
Peters, K.E.; Ramos, L.S.; Zumberge, J.E.; Valin, Z.C.; Scotese, C.R.; Gautier, D.L.
2007-01-01
Source- and age-related biomarker and isotopic data were measured for more than 1000 crude oil samples from wells and seeps collected above approximately 55??N latitude. A unique, multitiered chemometric (multivariate statistical) decision tree was created that allowed automated classification of 31 genetically distinct circumArctic oil families based on a training set of 622 oil samples. The method, which we call decision-tree chemometrics, uses principal components analysis and multiple tiers of K-nearest neighbor and SIMCA (soft independent modeling of class analogy) models to classify and assign confidence limits for newly acquired oil samples and source rock extracts. Geochemical data for each oil sample were also used to infer the age, lithology, organic matter input, depositional environment, and identity of its source rock. These results demonstrate the value of large petroleum databases where all samples were analyzed using the same procedures and instrumentation. Copyright ?? 2007. The American Association of Petroleum Geologists. All rights reserved.
Paretti, Nicholas; Coes, Alissa L.; Kephart, Christopher M.; Mayo, Justine
2018-03-05
Tumacácori National Historical Park protects the culturally important Mission, San José de Tumacácori, while also managing a portion of the ecologically diverse riparian corridor of the Santa Cruz River. This report describes the methods and quality assurance procedures used in the collection of water samples for the analysis of Escherichia coli (E. coli), microbial source tracking markers, suspended sediment, water-quality parameters, turbidity, and the data collection for discharge and stage; the process for data review and approval is also described. Finally, this report provides a quantitative assessment of the quality of the E. coli, microbial source tracking, and suspended sediment data.The data-quality assessment revealed that bias attributed to field and laboratory contamination was minimal, with E. coli detections in only 3 out of 33 field blank samples analyzed. Concentrations in the field blanks were several orders of magnitude lower than environmental concentrations. The microbial source tracking (MST) field blank was below the detection limit for all MST markers analyzed. Laboratory blanks for E. coli at the USGS Arizona Water Science Center and laboratory blanks for MST markers at the USGS Ohio Water Microbiology Laboratory were all below the detection limit. Irreplicate data for E. coli and suspended sediment indicated that bias was not introduced to the data by combining samples collected using discrete sampling methods with samples collected using automatic sampling methods.The split and sequential E. coli replicate data showed consistent analytical variability and a single equation was developed to explain the variability of E. coli concentrations. An additional analysis of analytical variability for E. coli indicated analytical variability around 18 percent relative standard deviation and no trend was observed in the concentration during the processing and analysis of multiple split-replicates. Two replicate samples were collected for MST and individual markers were compared for a base flow and flood sample. For the markers found in common between the two types of samples, the relative standard deviation for the base flow sample was more than 3 times greater than the markers in the flood sample. Sequential suspended sediment replicates had a relative standard deviation of about 1.3 percent, indicating that environmental and analytical variability was minimal.A holding time review and laboratory study analysis supported the extended holding times required for this investigation. Most concentrations for flood and base-flow samples were within the theoretical variability specified in the most probable number approach suggesting that extended hold times did not overly influence the final concentrations reported.
Traceability of Plant Diet Contents in Raw Cow Milk Samples
Ponzoni, Elena; Mastromauro, Francesco; Gianì, Silvia; Breviario, Diego
2009-01-01
The use of molecular marker in the dairy sector is gaining large acceptance as a reliable diagnostic approach for food authenticity and traceability. Using a PCR approach, the rbcL marker, a chloroplast-based gene, was selected to amplify plant DNA fragments in raw cow milk samples collected from stock farms or bought on the Italian market. rbcL-specific DNA fragments could be found in total milk, as well as in the skimmed and the cream fractions. When the PCR amplified fragments were sent to sequence, the nucleotide composition of the chromatogram reflected the multiple contents of the polyphytic diet. PMID:22253982
Miner, Michael H.; Bockting, Walter O.; Romine, Rebecca Swinburne; Raman, Sivakumaran
2013-01-01
Health research on transgender people has been hampered by the challenges inherent in studying a hard-to-reach, relatively small, and geographically dispersed population. The Internet has the potential to facilitate access to transgender samples large enough to permit examination of the diversity and syndemic health disparities found among this population. In this article, we describe the experiences of a team of investigators using the Internet to study HIV risk behaviors of transgender people in the United States. We developed an online instrument, recruited participants exclusively via websites frequented by members of the target population, and collected data using online quantitative survey and qualitative synchronous and asynchronous interview methods. Our experiences indicate that the Internet environment presents the investigator with some unique challenges and that commonly expressed criticisms about Internet research (e.g., lack of generalizable samples, invalid study participants, and multiple participation by the same subject) can be overcome with careful method design, usability testing, and pilot testing. The importance of both usability and pilot testing are described with respect to participant engagement and retention and the quality of data obtained online. PMID:24031157
NASA Astrophysics Data System (ADS)
Blum, M. D.; Umbarger, K.
2017-12-01
The Triassic Chinle Formation is a fluvial succession deposited in a backarc setting across the present-day Colorado Plateau of the southwestern United States. Existing studies have proposed various mechanisms responsible for the unique stratigraphic architecture and depositional sequences of the Chinle. However, these studies lack necessary age control to correlate stratigraphic patterns with contemporaneous mechanisms. This study will collect new samples for detrital zircon analysis, as well as upgrade existing samples (to n=300) from Dickinson and Gehrels (2008), to improve the resolution of Triassic sediment provenance from source-to-sink. The improved dataset allows appraisal of the multiple provenance terranes that contributed to the Chinle depositional system to delineate and reconstruct paleodrainage patterns. The additional samples will be collected systematically from the base of the Chinle, and vertically throughout the section to capture a regional story of how the continental scale drainage reorganized through time. U-Pb ages of detrital zircons will be utilized to provide quantitative fingerprinting information to constrain interpretations for the origin and transport history of the Chinle fluvial succession in time and space.
Miner, Michael H; Bockting, Walter O; Romine, Rebecca Swinburne; Raman, Sivakumaran
2012-05-01
Health research on transgender people has been hampered by the challenges inherent in studying a hard-to-reach, relatively small, and geographically dispersed population. The Internet has the potential to facilitate access to transgender samples large enough to permit examination of the diversity and syndemic health disparities found among this population. In this article, we describe the experiences of a team of investigators using the Internet to study HIV risk behaviors of transgender people in the United States. We developed an online instrument, recruited participants exclusively via websites frequented by members of the target population, and collected data using online quantitative survey and qualitative synchronous and asynchronous interview methods. Our experiences indicate that the Internet environment presents the investigator with some unique challenges and that commonly expressed criticisms about Internet research (e.g., lack of generalizable samples, invalid study participants, and multiple participation by the same subject) can be overcome with careful method design, usability testing, and pilot testing. The importance of both usability and pilot testing are described with respect to participant engagement and retention and the quality of data obtained online.
Monitoring heavy metal Cr in soil based on hyperspectral data using regression analysis
NASA Astrophysics Data System (ADS)
Zhang, Ningyu; Xu, Fuyun; Zhuang, Shidong; He, Changwei
2016-10-01
Heavy metal pollution in soils is one of the most critical problems in the global ecology and environment safety nowadays. Hyperspectral remote sensing and its application is capable of high speed, low cost, less risk and less damage, and provides a good method for detecting heavy metals in soil. This paper proposed a new idea of applying regression analysis of stepwise multiple regression between the spectral data and monitoring the amount of heavy metal Cr by sample points in soil for environmental protection. In the measurement, a FieldSpec HandHeld spectroradiometer is used to collect reflectance spectra of sample points over the wavelength range of 325-1075 nm. Then the spectral data measured by the spectroradiometer is preprocessed to reduced the influence of the external factors, and the preprocessed methods include first-order differential equation, second-order differential equation and continuum removal method. The algorithms of stepwise multiple regression are established accordingly, and the accuracy of each equation is tested. The results showed that the accuracy of first-order differential equation works best, which makes it feasible to predict the content of heavy metal Cr by using stepwise multiple regression.
Akter, Tahera; Jhohura, Fatema Tuz; Akter, Fahmida; Chowdhury, Tridib Roy; Mistry, Sabuj Kanti; Dey, Digbijoy; Barua, Milan Kanti; Islam, Md Akramul; Rahman, Mahfuzar
2016-02-09
Public health is at risk due to chemical contaminants in drinking water which may have immediate health consequences. Drinking water sources are susceptible to pollutants depending on geological conditions and agricultural, industrial, and other man-made activities. Ensuring the safety of drinking water is, therefore, a growing problem. To assess drinking water quality, we measured multiple chemical parameters in drinking water samples from across Bangladesh with the aim of improving public health interventions. In this cross-sectional study conducted in 24 randomly selected upazilas, arsenic was measured in drinking water in the field using an arsenic testing kit and a sub-sample was validated in the laboratory. Water samples were collected to test water pH in the laboratory as well as a sub-sample of collected drinking water was tested for water pH using a portable pH meter. For laboratory testing of other chemical parameters, iron, manganese, and salinity, drinking water samples were collected from 12 out of 24 upazilas. Drinking water at sample sites was slightly alkaline (pH 7.4 ± 0.4) but within acceptable limits. Manganese concentrations varied from 0.1 to 5.5 mg/L with a median value of 0.2 mg/L. The median iron concentrations in water exceeded WHO standards (0.3 mg/L) at most of the sample sites and exceeded Bangladesh standards (1.0 mg/L) at a few sample sites. Salinity was relatively higher in coastal districts. After laboratory confirmation, arsenic concentrations were found higher in Shibchar (Madaripur) and Alfadanga (Faridpur) compared to other sample sites exceeding WHO standard (0.01 mg/L). Of the total sampling sites, 33 % had good-quality water for drinking based on the Water Quality Index (WQI). However, the majority of the households (67 %) used poor-quality drinking water. Higher values of iron, manganese, and arsenic reduced drinking water quality. Awareness raising on chemical contents in drinking water at household level is required to improve public health.
Publishing Linked Open Data for Physical Samples - Lessons Learned
NASA Astrophysics Data System (ADS)
Ji, P.; Arko, R. A.; Lehnert, K.; Bristol, S.
2016-12-01
Most data and information about physical samples and associated sampling features currently reside in relational databases. Integrating common concepts from various databases has motivated us to publish Linked Open Data for collections of physical samples, using Semantic Web technologies including the Resource Description Framework (RDF), RDF Query Language (SPARQL), and Web Ontology Language (OWL). The goal of our work is threefold: To evaluate and select ontologies in different granularities for common concepts; to establish best practices and develop a generic methodology for publishing physical sample data stored in relational database as Linked Open Data; and to reuse standard community vocabularies from the International Commission on Stratigraphy (ICS), Global Volcanism Program (GVP), General Bathymetric Chart of the Oceans (GEBCO), and others. Our work leverages developments in the EarthCube GeoLink project and the Interdisciplinary Earth Data Alliance (IEDA) facility for modeling and extracting physical sample data stored in relational databases. Reusing ontologies developed by GeoLink and IEDA has facilitated discovery and integration of data and information across multiple collections including the USGS National Geochemical Database (NGDB), System for Earth Sample Registration (SESAR), and Index to Marine & Lacustrine Geological Samples (IMLGS). We have evaluated, tested, and deployed Linked Open Data tools including Morph, Virtuoso Server, LodView, LodLive, and YASGUI for converting, storing, representing, and querying data in a knowledge base (RDF triplestore). Using persistent identifiers such as Open Researcher & Contributor IDs (ORCIDs) and International Geo Sample Numbers (IGSNs) at the record level makes it possible for other repositories to link related resources such as persons, datasets, documents, expeditions, awards, etc. to samples, features, and collections. This work is supported by the EarthCube "GeoLink" project (NSF# ICER14-40221 and others) and the "USGS-IEDA Partnership to Support a Data Lifecycle Framework and Tools" project (USGS# G13AC00381).
Psychological traits underlying different killing methods among Malaysian male murderers.
Kamaluddin, Mohammad Rahim; Shariff, Nadiah Syariani; Nurfarliza, Siti; Othman, Azizah; Ismail, Khaidzir H; Mat Saat, Geshina Ayu
2014-04-01
Murder is the most notorious crime that violates religious, social and cultural norms. Examining the types and number of different killing methods that used are pivotal in a murder case. However, the psychological traits underlying specific and multiple killing methods are still understudied. The present study attempts to fill this gap in knowledge by identifying the underlying psychological traits of different killing methods among Malaysian murderers. The study adapted an observational cross-sectional methodology using a guided self-administered questionnaire for data collection. The sampling frame consisted of 71 Malaysian male murderers from 11 Malaysian prisons who were selected using purposive sampling method. The participants were also asked to provide the types and number of different killing methods used to kill their respective victims. An independent sample t-test was performed to establish the mean score difference of psychological traits between the murderers who used single and multiple types of killing methods. Kruskal-Wallis tests were carried out to ascertain the psychological trait differences between specific types of killing methods. The results suggest that specific psychological traits underlie the type and number of different killing methods used during murder. The majority (88.7%) of murderers used a single method of killing. Multiple methods of killing was evident in 'premeditated' murder compared to 'passion' murder, and revenge was a common motive. Examples of multiple methods are combinations of stabbing and strangulation or slashing and physical force. An exception was premeditated murder committed with shooting, when it was usually a single method, attributed to the high lethality of firearms. Shooting was also notable when the motive was financial gain or related to drug dealing. Murderers who used multiple killing methods were more aggressive and sadistic than those who used a single killing method. Those who used multiple methods or slashing also displayed a higher level of minimisation traits. Despite its limitations, this study has provided some light on the underlying psychological traits of different killing methods which is useful in the field of criminology.
Utilizing a Tower Based System for Optical Sensing of Ecosystem Carbon Fluxes
NASA Astrophysics Data System (ADS)
Huemmrich, K. F.; Corp, L. A.; Middleton, E.; Campbell, P. K. E.; Landis, D.; Kustas, W. P.
2015-12-01
Optical sampling of spectral reflectance and solar induced fluorescence provide information on the physiological status of vegetation that can be used to infer stress responses and estimates of production. Multiple repeated observations are required to observe the effects of changing environmental conditions on vegetation. This study examines the use of optical signals to determine inputs to a light use efficiency (LUE) model describing productivity of a cornfield where repeated observations of carbon flux, spectral reflectance and fluorescence were collected. Data were collected at the Optimizing Production Inputs for Economic and Environmental Enhancement (OPE3) fields (39.03°N, 76.85°W) at USDA Beltsville Agricultural Research Center. Agricultural Research Service researchers measured CO2 fluxes using eddy covariance methods throughout the growing season. Optical measurements were made from the nearby tower supporting the NASA FUSION sensors. The sensor system consists of two dual channel, upward and downward looking, spectrometers used to simultaneously collect high spectral resolution measurements of reflected and fluoresced light from vegetation canopies at multiple view angles. Estimates of chlorophyll fluorescence, combined with measures of vegetation pigment content and the Photosynthetic Reflectance Index (PRI) derived from the spectral reflectance are compared with CO2 fluxes over diurnal periods for multiple days. The relationships among the different optical measurements indicate that they are providing different types of information on the vegetation and that combinations of these measurements provide improved retrievals of CO2 fluxes than any index alone
Moore, Kimberly Sena; Peterson, David A; O'Shea, Geoffrey; McIntosh, Gerald C; Thaut, Michael H
2008-01-01
Research shows that people with multiple sclerosis exhibit learning and memory difficulties and that music can be used successfully as a mnemonic device to aid in learning and memory. However, there is currently no research investigating the effectiveness of music mnemonics as a compensatory learning strategy for people with multiple sclerosis. Participants with clinically definitive multiple sclerosis (N = 38) were given a verbal learning and memory test. Results from a recognition memory task were analyzed that compared learning through music (n = 20) versus learning through speech (n = 18). Preliminary baseline neuropsychological data were collected that measured executive functioning skills, learning and memory abilities, sustained attention, and level of disability. An independent samples t test showed no significant difference between groups on baseline neuropsychological functioning or on recognition task measures. Correlation analyses suggest that music mnemonics may facilitate learning for people who are less impaired by the disease. Implications for future research are discussed.
Sun, Yangbo; Chen, Long; Huang, Bisheng; Chen, Keli
2017-07-01
As a mineral, the traditional Chinese medicine calamine has a similar shape to many other minerals. Investigations of commercially available calamine samples have shown that there are many fake and inferior calamine goods sold on the market. The conventional identification method for calamine is complicated, therefore as a result of the large scale of calamine samples, a rapid identification method is needed. To establish a qualitative model using near-infrared (NIR) spectroscopy for rapid identification of various calamine samples, large quantities of calamine samples including crude products, counterfeits and processed products were collected and correctly identified using the physicochemical and powder X-ray diffraction method. The NIR spectroscopy method was used to analyze these samples by combining the multi-reference correlation coefficient (MRCC) method and the error back propagation artificial neural network algorithm (BP-ANN), so as to realize the qualitative identification of calamine samples. The accuracy rate of the model based on NIR and MRCC methods was 85%; in addition, the model, which took comprehensive multiple factors into consideration, can be used to identify crude calamine products, its counterfeits and processed products. Furthermore, by in-putting the correlation coefficients of multiple references as the spectral feature data of samples into BP-ANN, a BP-ANN model of qualitative identification was established, of which the accuracy rate was increased to 95%. The MRCC method can be used as a NIR-based method in the process of BP-ANN modeling.
The AstraLux Multiplicity Survey: Extension to Late M-dwarfs
NASA Astrophysics Data System (ADS)
Janson, Markus; Bergfors, Carolina; Brandner, Wolfgang; Kudryavtseva, Natalia; Hormuth, Felix; Hippler, Stefan; Henning, Thomas
2014-07-01
The distribution of multiplicity among low-mass stars is a key issue to understanding the formation of stars and brown dwarfs, and recent surveys have yielded large enough samples of nearby low-mass stars to study this issue statistically to good accuracy. Previously, we have presented a multiplicity study of ~700 early/mid M-type stars observed with the AstraLux high-resolution Lucky Imaging cameras. Here, we extend the study of multiplicity in M-type stars through studying 286 nearby mid/late M-type stars, bridging the gap between our previous study and multiplicity studies of brown dwarfs. Most of the targets have been observed more than once, allowing us to assess common proper motion to confirm companionship. We detect 68 confirmed or probable companions in 66 systems, of which 41 were previously undiscovered. Detections are made down to the resolution limit of ~100 mas of the instrument. The raw multiplicity in the AstraLux sensitivity range is 17.9%, leading to a total multiplicity fraction of 21%-27% depending on the mass ratio distribution, which is consistent with being flat down to mass ratios of ~0.4, but cannot be stringently constrained below this value. The semi-major axis distribution is well represented by a log-normal function with μa = 0.78 and σa = 0.47, which is narrower and peaked at smaller separations than for a Sun-like sample. This is consistent with a steady decrease in average semi-major axis from the highest-mass binary stars to the brown dwarf binaries. Based on observations collected at the Centro Astronómico Hispano Alemán (CAHA) at Calar Alto, operated jointly by the Max-Planck Institute for Astronomy and the Instituto de Astrofísica de Andalucía (CSIC).
Quiet Ego, Self-Regulatory Skills, and Perceived Stress in College Students.
Wayment, Heidi A; Cavolo, Keragan
2018-04-13
Examine the unique contributions of self-control and grit subscales (perseverance, interest consistency) as potential mediators of the relationship between quiet ego characteristics and less perceived stress in college students. Data from 1117 college students were collected between October, 2015 and May, 2016. The sample was split randomly into exploratory and confirmatory samples. Multiple mediator models were tested with PROCESS module (SPSS v. 24) in both samples. Hypotheses were largely confirmed with self-control fully mediating the link between quiet ego and perceived stress in both samples. Although many self-regulatory constructs may argue for their positive impact on college student outcomes, interventions that strengthen self-control, and not grit, may be most promising to reduce perceived stress. Further, interventions to strengthen quiet ego characteristics may be beneficial for strengthening self-control in college students.
Neural Network and Nearest Neighbor Algorithms for Enhancing Sampling of Molecular Dynamics.
Galvelis, Raimondas; Sugita, Yuji
2017-06-13
The free energy calculations of complex chemical and biological systems with molecular dynamics (MD) are inefficient due to multiple local minima separated by high-energy barriers. The minima can be escaped using an enhanced sampling method such as metadynamics, which apply bias (i.e., importance sampling) along a set of collective variables (CV), but the maximum number of CVs (or dimensions) is severely limited. We propose a high-dimensional bias potential method (NN2B) based on two machine learning algorithms: the nearest neighbor density estimator (NNDE) and the artificial neural network (ANN) for the bias potential approximation. The bias potential is constructed iteratively from short biased MD simulations accounting for correlation among CVs. Our method is capable of achieving ergodic sampling and calculating free energy of polypeptides with up to 8-dimensional bias potential.
NASA Astrophysics Data System (ADS)
Fisher, Christopher M.; Paton, Chad; Pearson, D. Graham; Sarkar, Chiranjeeb; Luo, Yan; Tersmette, Daniel B.; Chacko, Thomas
2017-12-01
A robust platform to view and integrate multiple data sets collected simultaneously is required to realize the utility and potential of the Laser Ablation Split-Stream (LASS) method. This capability, until now, has been unavailable and practitioners have had to laboriously process each data set separately, making it challenging to take full advantage of the benefits of LASS. We describe a new program for handling multiple mass spectrometric data sets collected simultaneously, designed specifically for the LASS technique, by which a laser aerosol is been split into two or more separate "streams" to be measured on separate mass spectrometers. New features within Iolite (https://iolite-software.com) enable the capability of loading, synchronizing, viewing, and reducing two or more data sets acquired simultaneously, as multiple DRSs (data reduction schemes) can be run concurrently. While this version of Iolite accommodates any combination of simultaneously collected mass spectrometer data, we demonstrate the utility using case studies where U-Pb and Lu-Hf isotope composition of zircon, and U-Pb and Sm-Nd isotope composition of monazite were analyzed simultaneously, in crystals showing complex isotopic zonation. These studies demonstrate the importance of being able to view and integrate simultaneously acquired data sets, especially for samples with complicated zoning and decoupled isotope systematics, in order to extract accurate and geologically meaningful isotopic and compositional data. This contribution provides instructions and examples for handling simultaneously collected laser ablation data. An instructional video is also provided. The updated Iolite software will help to fully develop the applications of both LASS and multi-instrument mass spectrometric measurement capabilities.
NASA Astrophysics Data System (ADS)
Scherrer, Nadim C.; Stefan, Zumbuehl; Francoise, Delavy; Annette, Fritsch; Renate, Kuehnen
2009-08-01
Some 170 organic pigments relevant to artist's paints have been collected from historic collections and modern manufacturers. The number includes multiples of the same pigment from different sources and comprises 118 different color indices (C.I.). All of them have been analysed with FTIR spectroscopy and 125 pigments (93 different C.I. No.s) of particular relevance to artist's paints have been characterised with Raman spectroscopy so far. The pigment collection encompasses the following pigment classes and subgroups: monoazo pigments represented by acetoacetic arylide yellow (hansa yellow), β-naphthol, BON, naphthol AS and benzimidazolone; disazo pigments with disazo condensation, diarylide, bisacetoacetarylide, pyrazolone; azo-azomethin metal complex pigments; non-azo, polycyclic pigments such as phthalocyanines, diketopyrrolo-pyrroles (DPP), perylenes and perinones, quinacridones, isoindolinones, polycarbocyclic anthraquinones and dioxanines. The selection of references was based on availability (historic collections) and current use in 16 acrylic, alkyd and oil-based artist's paints, and it covers pigment colors PY yellow (27 C.I. No.s), PR red (38), PO orange (9), PB blue (8), PV violet (6), PG green (3) and PBr brown (2). Besides peak tables and spectra patterns, flow charts based on color, pigment class, group and individual color index are presented to help identification of unknowns and mixed paint samples. While Raman could isolate all different C.I. numbers, multiple references of the same C.I. from different sources could not be distinguished.
Tran, Jonathan Q; Othman, Ahmed A; Wolstencroft, Paul; Elkins, Jacob
2016-07-01
To characterize the potential effect of daclizumab high-yield process (DAC HYP), a monoclonal antibody that blocks the high-affinity interleukin-2 receptors for treatment of multiple sclerosis, on activity of cytochrome P450 (CYP) enzymes. Twenty patients with multiple sclerosis received an oral cocktail of probe substrates of CYP1A2 (caffeine 200 mg), CYP2C9 (warfarin 10 mg/vitamin K 10 mg), CYP2C19 (omeprazole 40 mg), CYP2D6 (dextromethorphan 30 mg) and CYP3A (midazolam 5 mg) on two sequential occasions: 7 days before and 7 days after subcutaneous administration of DAC HYP 150 mg every 4 weeks for three doses. Serial pharmacokinetic blood samples up to 96 h post dose and 12-h urine samples were collected on both occasions. Area under the curve (AUC) for caffeine, S-warfarin, omeprazole and midazolam, and urine dextromethorphan to dextrorphan ratio were calculated. Statistical analyses were conducted on log-transformed parameters using a linear mixed-effects model. The 90% confidence intervals (CIs) for the geometric mean ratio (probe substrate with DAC HYP/probe substrate alone) for caffeine AUC from 0-12 h (0.93-1.15), S-warfarin AUC from 0 to infinity (AUC[0-inf]) (0.95-1.06), omeprazole AUC(0-inf) (0.88-1.13) and midazolam AUC(0-inf) (0.89-1.15) were within the no-effect boundary of 0.80-1.25. The geometric mean ratio for urine dextromethorphan to dextrorphan ratio was 1.01, with the 90% CI (0.76-1.34) extending slightly outside the no-effect boundary, likely due to high variability with urine collections and CYP2D6 activity. DAC HYP treatment in patients with multiple sclerosis had no effect on CYP 1A2, 2C9, 2C19, 2D6 and 3A activity. © 2016 The British Pharmacological Society.
Diversity changes of microbial communities into hospital surface environments.
Yano, Rika; Shimoda, Tomoko; Watanabe, Reina; Kuroki, Yasutoshi; Okubo, Torahiko; Nakamura, Shinji; Matsuo, Junji; Yoshimura, Sadako; Yamaguchi, Hiroyuki
2017-07-01
Previous works have demonstrated considerable variability in hospital cleanliness in Japan, suggesting that contamination is driven by factors that are currently poorly controlled. We undertook 16S rRNA sequence analysis to study population structures of hospital environmental microbiomes to see which factor(s) impacted contamination. One hundred forty-four samples were collected from surfaces of three hospitals with distinct sizes ("A": >500 beds, "B": 100-500 beds, "C": <100 beds). Sample locations of two ward types (Surgical and Internal) included patient room bed table (multiple) (4BT), patient overbed table (multiple) (4OT), patient room sink (multiple) (4S), patient room bed table (single) (SBT), patient overbed table (single) (SOT), patient room sink (single) (SS), nurse desk (ND), and nurse wagon (NW). Total DNA was extracted from each sample, and the 50 samples that yielded sufficient DNA were used for further 16S rRNA sequencing of hospital microbiome populations with cluster analysis. The number of assigned bacterial OTU populations was significantly decreased in hospital "C" compared to the other hospitals. Cluster analysis of sampling locations revealed that the population structure in almost all locations of hospital "C" and some locations in the other hospitals was very similar and unusually skewed with a family, Enterobacteriaceae. Interestingly, locations included patient area (4OT, 4BT, SBT) and nurse area (ND), with a device (NW) bridging the two and a place (4S and SS) shared between patients or visitors. We demonstrated diversity changes of hospital environmental microbiomes with a skewed population, presumably by medical staff pushing NWs or sinks shared by patients or visitors. Copyright © 2017 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Prevalence and Correlates of School Bullying Victimization in Xi'an, China.
Zhu, Yuhong; Chan, Ko Ling
2015-01-01
This study used the data from a representative sample to estimate the prevalence of child bullying victimization in Xi'an, China. Data on social demographic information and the experiences of different types of bullying victimization were collected from a randomly selected sample with 3,175 middle school students aged 15-17 years by self-administrated questionnaires. t Test, χ2 test, and multiple logistic regression analyses were used to test group differences and examine the correlates of bullying victimization. Results show that 54.9% and 44.6% of Chinese children have been bullied in a lifetime and in the preceding year, respectively. Correlates for direct and relational bullying victimization includes male participants, father's lower education level, father's unemployment, having one or more siblings, smoking, depression, borderline personality trait, posttraumatic stress disorder, and from rural schools. Overall, the prevalence of child bullying victimization in China is substantial. The multiple correlates suggest prevention and intervention of bullying victimization in a holistic and comprehensive way.
Students’ Conception on Heat and Temperature toward Science Process Skill
NASA Astrophysics Data System (ADS)
Ratnasari, D.; Sukarmin, S.; Suparmi, S.; Aminah, N. S.
2017-09-01
This research is aimed to analyze the effect of students’ conception toward science process skill. This is a descriptive research with subjects of the research were 10th-grade students in Surakarta from high, medium and low categorized school. The sample selection uses purposive sampling technique based on physics score in national examination four latest years. Data in this research collecting from essay test, two-tier multiple choice test, and interview. Two-tier multiple choice test consists of 30 question that contains an indicator of science process skill. Based on the result of the research and analysis, it shows that students’ conception of heat and temperature affect science process skill of students. The students’ conception that still contains the wrong concept can emerge misconception. For the future research, it is suggested to improve students’ conceptual understanding and students’ science process skill with appropriate learning method and assessment instrument because heat and temperature is one of physics material that closely related with students’ daily life.
NASA Technical Reports Server (NTRS)
Wells, W. C.
1978-01-01
Various science disciplines were examined to determine where and when it is appropriate to include their objectives in the planning of planetary missions. The disciplines considered are solar astronomy, stellar and galactic astronomy, solar physics, cosmology and gravitational physics, the geosciences and the applied sciences. For each discipline, science objectives are identified which could provide a multiple discipline opportunity utilizing either a single spacecraft or two spacecraft delivered by a single launch vehicle. Opportunities using a common engineering system are also considered. The most promising opportunities identified include observations of solar images and relativistic effects using the Mercury orbiter; collection of samples exposed to solar radiation using the Mars surface sample return; studies of interstellar neutral H and He, magnetic fields, cosmic rays, and solar physics during Pluto or Neptune flybys; using the Mars orbiter to obtain solar images from 0.2 AU synchronous or from 90 deg orbit; and the study of the structure and composition of the atmosphere using atmospheric probes and remotely piloted vehicles.
NASA Astrophysics Data System (ADS)
Alimi, Isiaka; Shahpari, Ali; Ribeiro, Vítor; Sousa, Artur; Monteiro, Paulo; Teixeira, António
2017-05-01
In this paper, we present experimental results on channel characterization of single input single output (SISO) free-space optical (FSO) communication link that is based on channel measurements. The histograms of the FSO channel samples and the log-normal distribution fittings are presented along with the measured scintillation index. Furthermore, we extend our studies to diversity schemes and propose a closed-form expression for determining ergodic channel capacity of multiple input multiple output (MIMO) FSO communication systems over atmospheric turbulence fading channels. The proposed empirical model is based on SISO FSO channel characterization. Also, the scintillation effects on the system performance are analyzed and results for different turbulence conditions are presented. Moreover, we observed that the histograms of the FSO channel samples that we collected from a 1548.51 nm link have good fits with log-normal distributions and the proposed model for MIMO FSO channel capacity is in conformity with the simulation results in terms of normalized mean-square error (NMSE).
Wang, Zhuo; Jin, Shuilin; Liu, Guiyou; Zhang, Xiurui; Wang, Nan; Wu, Deliang; Hu, Yang; Zhang, Chiping; Jiang, Qinghua; Xu, Li; Wang, Yadong
2017-05-23
The development of single-cell RNA sequencing has enabled profound discoveries in biology, ranging from the dissection of the composition of complex tissues to the identification of novel cell types and dynamics in some specialized cellular environments. However, the large-scale generation of single-cell RNA-seq (scRNA-seq) data collected at multiple time points remains a challenge to effective measurement gene expression patterns in transcriptome analysis. We present an algorithm based on the Dynamic Time Warping score (DTWscore) combined with time-series data, that enables the detection of gene expression changes across scRNA-seq samples and recovery of potential cell types from complex mixtures of multiple cell types. The DTWscore successfully classify cells of different types with the most highly variable genes from time-series scRNA-seq data. The study was confined to methods that are implemented and available within the R framework. Sample datasets and R packages are available at https://github.com/xiaoxiaoxier/DTWscore .
2011-01-01
Background The characterization of malaria parasite populations circulating in an area is part of site characterization, as a basis for evaluating the impact of malaria interventions on genetic diversity, parasite species, and multiplicity of infection. The present study was aimed at analysing genetic diversity of Plasmodium falciparum merozoite surface proteins 1 and 2 (MSP-1 and MSP-2) and to determine the multiplicity of infection in clinical isolates collected from children living in the Southern district of Brazzaville in the Republic of Congo. Methods A total of 125 isolates from patients with uncomplicated malaria attending Terinkyo and Madibou health centres were collected between January and June 2005 while evaluating the therapeutic efficacy of amodiaquine-artesunate combination. DNA was extracted and msp-1 and msp-2 genes were genotyped using allele-specific nested-PCR. Results Out of 468 distinct fragments detected, 15 msp-1 and 20 msp-2 genotypes were identified. For the msp-1 gene, K1 family was the predominant allelic type carried alone or in association with RO33 and Mad20 types, whereas the 3D7 family was the most prevalent in the msp-2 gene. Overall, the mean multiplicity of infection was 2.2. Out of 125 samples, 104 (83%) harboured more than one parasite genotype. There was no statistical significant difference in the multiplicity of infection by either sex or age of patients. However, a statistically significant correlation was found between parasite densities and the number of genotypes. Conclusion Polymorphism in P. falciparum clinical isolates from Brazzaville was high and mainly of multiple clones. The basis for the positive association between parasite densities and multiplicity of infection is discussed. PMID:21936949
NASA Astrophysics Data System (ADS)
Horst, A.; Varga, R. J.; Gee, J. S.; Karson, J. A.
2006-12-01
The tectonic window at the Pito Deep Rift exposes super-fast spread (>140mm/yr) oceanic crust created at the East Pacific Rise (EPR). Observations and investigations of well-exposed cross sections into modern ocean crust, such as Pito Deep, provide essential insights into ridge crest dynamics. Paleomagnetic analysis provides a quantitative means for assessing both magnitude and style of structural rotations of oceanic crust. The Pito Cruise 2005 collected 69 fully oriented samples [67 dikes, 2 gabbros] during several ALVIN and JASON II dives. These samples were all oriented in situ using the Geocompass. Along the escarpment of Pito Deep, dike orientations have consistant NE strikes and SE dips. These dikes are all formed roughly 3 million years ago at the EPR located to the west of their present position. We determined magnetic remanence for a subset of 34 oriented blocks. A majority of dikes in this subset have normal polarity and many are clockwise rotated from expected orientations. To assess possible orientation errors during collection, we sampled multiple dikes from relatively small areas. On ALVIN dive 4081, for example, we collected 14 samples from a well-exposed, subparallel series of dikes. These dikes provide stable and consistently oriented remanence directions suggesting that errors in the collection process are small. Remanence data collected to date verify tectonic models that suggest clockwise rotation of the Easter microplate, consistent with current models. In addition to magnetic remanence, we determined the anisotropy of magnetic susceptibility (AMS) of the 34 dike samples. AMS studies have proven their utility in a wide range of geological studies and have been shown to determine flow direction within dikes in a variety of settings. In most Pito Deep samples, two of three AMS eigenvectors lie close to dike plane orientations. Kmin generally lies perpendicular to dike planes while, in most samples, Kmax is shallow indicating dominantly subhorizontal magma flow. Steep Kmax in a few samples indicates vertical flow directions suggestive of primary flow or of gravitational back-flow during the waning stages of dike injection. Primarily horizontal magma flow in dikes might indicate injection of magma from a centralized magma chamber toward a plate segment boundary.
McNeel, Anthony K; Ondrak, Jeff D; Cushman, Robert A
2013-05-01
Placental separation is a complex physiological event in reproductive physiology and the underlying molecular mechanisms remain unclear. When comparing different experiments the timing of tissue collections is a significant consideration due to the variability in time between fetal expulsion and expulsion of the placenta (30 min to >24 h). This makes comparison of tissues samples across animals difficult and supports the need for serial tissue collections within animal. Additionally, the instrument most commonly used, a modified Richter-Resinsinger effeminator, for placentome collections is difficult to obtain and there are no data in the literature record regarding subsequent reproductive performance of animals subjected placentome collections. To facilitate continued research into the physiology behind placental separation, we designed an instrument from readily available components and performed serial transvaginal placentome collections in cattle. Three placentomes at 2-h intervals were collected after expulsion of the calf in 18 multiparous cows. There was no incidence of mortality and all cows resumed estrous after the procedure. Neither time from placentome collection nor age had a significant effect on pregnancy status at diagnosis (P > 0.05). These results demonstrate the viability of and utility of this device for collecting multiple placentomes in cattle.
Genetic heterogeneity of hepatitis E virus in Darfur, Sudan, and neighboring Chad.
Nicand, Elisabeth; Armstrong, Gregory L; Enouf, Vincent; Guthmann, Jean Paul; Guerin, Jean-Philippe; Caron, Mélanie; Nizou, Jacques Yves; Andraghetti, Roberta
2005-12-01
The within-outbreak diversity of hepatitis E virus (HEV) was studied during the outbreak of hepatitis E that occurred in Sudan in 2004. Specimens were collected from internally displaced persons living in a Sudanese refugee camp and two camps implanted in Chad. A comparison of the sequences in the ORF2 region of 23 Sudanese isolates and five HEV samples from the two Chadian camps displayed a high similarity (>99.7%) to strains belonging to Genotype 1. But four isolates collected in one of the Chadian camps were close to Genotype 2. Circulation of divergent strains argues for possible multiple sources of infection. Copyright (c) 2005 Wiley-Liss, inc.
Tosi, Simone; Costa, Cecilia; Vesco, Umberto; Quaglia, Giancarlo; Guido, Giovanni
2018-02-15
Honey bee (Apis mellifera L.) health is compromised by complex interactions between multiple stressors, among which pesticides play a major role. To better understand the extent of honey bee colonies' exposure to pesticides in time and space, we conducted a survey by collecting corbicular pollen from returning honey bee foragers in 53 Italian apiaries during the active beekeeping season of 3 subsequent years (2012-2014). Of 554 pollen samples analysed for pesticide residues, 62% contained at least one pesticide. The overall rate of multiresidual samples (38%) was higher than the rate of single pesticide samples (24%), reaching a maximum of 7 pesticides per sample (1%). Over 3years, 18 different pesticides were detected (10 fungicides and 8 insecticides) out of 66 analysed. Pesticide concentrations reached the level of concern for bee health (Hazard Quotient (HQ) higher than 1000) at least once in 13% of the apiaries and exceeded the thresholds of safety for human dietary intake (Acute Reference Dose (ARfD), the Acceptable Daily Intake (ADI), and the Maximum Residue Limit (MRL)) in 39% of the analysis. The pesticide which was most frequently detected was the insecticide chlorpyrifos (30% of the samples overall, exceeding ARfD, ADI, or MRL in 99% of the positive ones), followed by the fungicides mandipropamid (19%), metalaxyl (16%), spiroxamine (15%), and the neonicotinoid insecticide imidacloprid (12%). Imidacloprid had also the highest HQ level (5054, with 12% of its positive samples with HQ higher than 1000). This 3year survey provides further insights on the contamination caused by agricultural pesticide use on honey bee colonies. Bee-collected pollen is shown to be a valuable tool for environmental monitoring, and for the detection of illegal uses of pesticides. Copyright © 2017 Elsevier B.V. All rights reserved.
Noninvasive molecular tracking of colonizing wolf (Canis lupus) packs in the western Italian Alps.
Lucchini, V; Fabbri, E; Marucco, F; Ricci, S; Boitani, L; Randi, E
2002-05-01
We used noninvasive methods to obtain genetic and demographic data on the wolf packs (Canis lupus), which are now recolonizing the Alps, a century after their eradication. DNA samples, extracted from presumed wolf scats collected in the western Italian Alps (Piemonte), were genotyped to determine species and sex by sequencing parts of the mitochondrial DNA (mtDNA) control-region and ZFX/ZFY genes. Individual genotypes were identified by multilocus microsatellite analyses using a multiple tubes polymerase chain reaction (PCR). The performance of the laboratory protocols was affected by the age of samples. The quality of excremental DNA extracts was higher in samples freshly collected on snow in winter than in samples that were older or collected during summer. Preliminary mtDNA screening of all samples allowed species identification and was a good predictor of further PCR performances. Wolf, and not prey, DNA targets were preferentially amplified. Allelic dropout occurred more frequently than false alleles, but the probability of false homozygote determinations was always < 0.001. A panel of six to nine microsatellites would allow identification of individual wolf genotypes, also whether related, with a probability of identity of < 0.015. Genealogical relationships among individuals could be determined reliably if the number of candidate parents was 6-8, and most of them had been sampled and correctly genotyped. Genetic data indicate that colonizing Alpine wolves originate exclusively from the Italian source population and retain a high proportion of its genetic diversity. Spatial and temporal locations of individual genotypes, and kinship analyses, suggest that two distinct packs of closely related wolves, plus some unrelated individuals, ranged in the study areas. This is in agreement with field observations.
Initial genome sequencing and analysis of multiple myeloma
Chapman, Michael A.; Lawrence, Michael S.; Keats, Jonathan J.; Cibulskis, Kristian; Sougnez, Carrie; Schinzel, Anna C.; Harview, Christina L.; Brunet, Jean-Philippe; Ahmann, Gregory J.; Adli, Mazhar; Anderson, Kenneth C.; Ardlie, Kristin G.; Auclair, Daniel; Baker, Angela; Bergsagel, P. Leif; Bernstein, Bradley E.; Drier, Yotam; Fonseca, Rafael; Gabriel, Stacey B.; Hofmeister, Craig C.; Jagannath, Sundar; Jakubowiak, Andrzej J.; Krishnan, Amrita; Levy, Joan; Liefeld, Ted; Lonial, Sagar; Mahan, Scott; Mfuko, Bunmi; Monti, Stefano; Perkins, Louise M.; Onofrio, Robb; Pugh, Trevor J.; Vincent Rajkumar, S.; Ramos, Alex H.; Siegel, David S.; Sivachenko, Andrey; Trudel, Suzanne; Vij, Ravi; Voet, Douglas; Winckler, Wendy; Zimmerman, Todd; Carpten, John; Trent, Jeff; Hahn, William C.; Garraway, Levi A.; Meyerson, Matthew; Lander, Eric S.; Getz, Gad; Golub, Todd R.
2013-01-01
Multiple myeloma is an incurable malignancy of plasma cells, and its pathogenesis is poorly understood. Here we report the massively parallel sequencing of 38 tumor genomes and their comparison to matched normal DNAs. Several new and unexpected oncogenic mechanisms were suggested by the pattern of somatic mutation across the dataset. These include the mutation of genes involved in protein translation (seen in nearly half of the patients), genes involved in histone methylation, and genes involved in blood coagulation. In addition, a broader than anticipated role of NF-κB signaling was suggested by mutations in 11 members of the NF-κB pathway. Of potential immediate clinical relevance, activating mutations of the kinase BRAF were observed in 4% of patients, suggesting the evaluation of BRAF inhibitors in multiple myeloma clinical trials. These results indicate that cancer genome sequencing of large collections of samples will yield new insights into cancer not anticipated by existing knowledge. PMID:21430775
NASA Astrophysics Data System (ADS)
Alami, Y.; Sinaga, P.; Setiawan, A.
2018-05-01
Based on recommendations from the Physics Education literature recommend the use of multiple representations to help students solve problems. The use of some good representations is considered important to study physics, so many good motivations to learn how students use multiple representations while solving problems and to learn how to solve problems using multiple representations. This study aims to explore the profile of high school students’ problem solving abilities and this study is part of a larger research focus on improving this ability in students in physics. The data is needed to determine the appropriate treatment to be used in subsequent research. A purposive sampling technique was used in this study and a survey was conducted to collect data. 74 students from one high school in Bandung were involved in this research.
NASA Astrophysics Data System (ADS)
Mulholland, Troy; CMS Collaboration
2016-03-01
We present a search for supersymmetry (SUSY) with data collected from the Compact Muon Solenoid (CMS) detector. The sample corresponds to 2 . 3fb-1 of proton-proton collisions with √{ s} = 13 TeV delivered by the Large Hadron Collider (LHC). The search looks at events with large hadronic activity, missing transverse energy, and without any identified leptons. The data are analyzed in bins of jet multiplicity, bottom-quark tagged jet (b-jet) multiplicity, scalar sum of jet transverse momentum, and vector sum of jet transverse momentum. A standard model (SM) background to this search includes the SM production of multiple jets and a Z boson that decays to two undetectable neutrinos. This talk focuses on the measurement of this particular background and its context in the wider search. Observations are consistent with SM backgrounds and limits are set on gluino mediated simplified SUSY models.
Multiplexed Colorimetric Solid-Phase Extraction
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Fritz, James S.; Porter, Marc D.
2009-01-01
Multiplexed colorimetric solid-phase extraction (MC-SPE) is an extension of colorimetric solid-phase extraction (C-SPE) an analytical platform that combines colorimetric reagents, solid phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water. In CSPE, analytes are extracted and complexed on the surface of an extraction membrane impregnated with a colorimetric reagent. The analytes are then quantified directly on the membrane surface using a handheld diffuse reflectance spectrophotometer. Importantly, the use of solid-phase extraction membranes as the matrix for impregnation of the colorimetric reagents creates a concentration factor that enables the detection of low concentrations of analytes in small sample volumes. In extending C-SPE to a multiplexed format, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple sample syringes have been designed, enabling the simultaneous determination of multiple analytes. Separate, single analyte membranes, placed in a readout cartridge create unique, analyte-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. In a demonstration, MC-SPE was used to measure the pH of a sample and quantitate Ag(I) and Ni(II).
1999-07-28
lag phase for Proteus vulgaris (Manko et al., 1987), E. coli, and B. subtilis (Kaceua and Todd, 1997) on orbit. However, due to a limited number of... limitations often precluded the collection of multiple bacterial counts at different times during the relatively short exponential growth phase. This...g, respectively. Because the 50 centriiiige held only 6 FPAs, the number of samples for each experiment was limited . To increase the «-value
NASA Technical Reports Server (NTRS)
Zhang, Ye; Yeshitla, Samrawit; Hada, Megumi; Kadhim, Munira; Wilson, Bobby; Wu, Honglu
2015-01-01
Numerous published studies have reported the Relative Biological Effectiveness (RBE) values for chromosome aberrations induced by charged particles of different LET. The RBE for chromosome aberrations in human lymphocytes exposed ex vivo has been suggested to show a similar relationship as the quality factor for cancer induction. Therefore, increased chromosome aberrations in the astronauts' white blood cells post long-duration missions are used to determine the biological doses from exposures to space radiation. However, the RBE value is known to be very different for different types of cancer. Previously, we reported that, even though the RBE for initial chromosome damages was high in human lymphocytes exposed to Fe ions, the RBE was significantly reduced after multiple cell divisions post irradiation. To test the hypothesis that RBE values for chromosome aberrations are cell type dependent, and different between early and late damages, we exposed human lymphocytes ex vivo, and human mammary epithelial cells in vitro to various charged particles. Chromosome aberrations were quantified using the samples collected at first mitosis post irradiation for initial damages, and the samples collected after multiple generations for the remaining or late arising aberrations. Results of the study suggested that the effectiveness of high-LET charged particles for late chromosome aberrations may be cell type dependent, even though the RBE values are similar for early damages.
Kassotis, Christopher D.; Tillitt, Donald E.; Davis, J. Wade; Hormann, Anette M.; Nagel, Susan C.
2014-01-01
The rapid rise in natural gas extraction using hydraulic fracturing increases the potential for contamination of surface and ground water from chemicals used throughout the process. Hundreds of products containing more than 750 chemicals and components are potentially used throughout the extraction process, including more than 100 known or suspected endocrine-disrupting chemicals. We hypothesized thataselected subset of chemicalsusedin natural gas drilling operationsandalso surface and ground water samples collected in a drilling-dense region of Garfield County, Colorado, would exhibit estrogen and androgen receptor activities. Water samples were collected, solid-phase extracted, and measured for estrogen and androgen receptor activities using reporter gene assays in human cell lines. Of the 39 unique water samples, 89%, 41%, 12%, and 46% exhibited estrogenic, antiestrogenic, androgenic, and antiandrogenic activities, respectively. Testing of a subset of natural gas drilling chemicals revealed novel antiestrogenic, novel antiandrogenic, and limited estrogenic activities. The Colorado River, the drainage basin for this region, exhibited moderate levels of estrogenic, antiestrogenic, and antiandrogenic activities, suggesting that higher localized activity at sites with known natural gas–related spills surrounding the river might be contributing to the multiple receptor activities observed in this water source. The majority of water samples collected from sites in a drilling-dense region of Colorado exhibited more estrogenic, antiestrogenic, or antiandrogenic activities than reference sites with limited nearby drilling operations. Our data suggest that natural gas drilling operationsmayresult in elevated endocrine-disrupting chemical activity in surface and ground water.
Automatic initialization for 3D bone registration
NASA Astrophysics Data System (ADS)
Foroughi, Pezhman; Taylor, Russell H.; Fichtinger, Gabor
2008-03-01
In image-guided bone surgery, sample points collected from the surface of the bone are registered to the preoperative CT model using well-known registration methods such as Iterative Closest Point (ICP). These techniques are generally very sensitive to the initial alignment of the datasets. Poor initialization significantly increases the chances of getting trapped local minima. In order to reduce the risk of local minima, the registration is manually initialized by locating the sample points close to the corresponding points on the CT model. In this paper, we present an automatic initialization method that aligns the sample points collected from the surface of pelvis with CT model of the pelvis. The main idea is to exploit a mean shape of pelvis created from a large number of CT scans as the prior knowledge to guide the initial alignment. The mean shape is constant for all registrations and facilitates the inclusion of application-specific information into the registration process. The CT model is first aligned with the mean shape using the bilateral symmetry of the pelvis and the similarity of multiple projections. The surface points collected using ultrasound are then aligned with the pelvis mean shape. This will, in turn, lead to initial alignment of the sample points with the CT model. The experiments using a dry pelvis and two cadavers show that the method can align the randomly dislocated datasets close enough for successful registration. The standard ICP has been used for final registration of datasets.
The collection of MicroED data for macromolecular crystallography.
Shi, Dan; Nannenga, Brent L; de la Cruz, M Jason; Liu, Jinyang; Sawtelle, Steven; Calero, Guillermo; Reyes, Francis E; Hattne, Johan; Gonen, Tamir
2016-05-01
The formation of large, well-ordered crystals for crystallographic experiments remains a crucial bottleneck to the structural understanding of many important biological systems. To help alleviate this problem in crystallography, we have developed the MicroED method for the collection of electron diffraction data from 3D microcrystals and nanocrystals of radiation-sensitive biological material. In this approach, liquid solutions containing protein microcrystals are deposited on carbon-coated electron microscopy grids and are vitrified by plunging them into liquid ethane. MicroED data are collected for each selected crystal using cryo-electron microscopy, in which the crystal is diffracted using very few electrons as the stage is continuously rotated. This protocol gives advice on how to identify microcrystals by light microscopy or by negative-stain electron microscopy in samples obtained from standard protein crystallization experiments. The protocol also includes information about custom-designed equipment for controlling crystal rotation and software for recording experimental parameters in diffraction image metadata. Identifying microcrystals, preparing samples and setting up the microscope for diffraction data collection take approximately half an hour for each step. Screening microcrystals for quality diffraction takes roughly an hour, and the collection of a single data set is ∼10 min in duration. Complete data sets and resulting high-resolution structures can be obtained from a single crystal or by merging data from multiple crystals.
NASA Astrophysics Data System (ADS)
Alpers, C. N.; Marvin-DiPasquale, M. C.; Fleck, J.; Ackerman, J. T.; Eagles-Smith, C.; Stewart, A. R.; Windham-Myers, L.
2016-12-01
Many watersheds in the western U.S. have mercury (Hg) contamination from historical mining of Hg and precious metals (gold and silver), which were concentrated using Hg amalgamation (mid 1800's to early 1900's). Today, specialized sampling and analytical protocols for characterizing Hg and methylmercury (MeHg) in water, sediment, and biota generate high-quality data to inform management of land, water, and biological resources. Collection of vertically and horizontally integrated water samples in flowing streams and use of a Teflon churn splitter or cone splitter ensure that samples and subsamples are representative. Both dissolved and particulate components of Hg species in water are quantified because each responds to different hydrobiogeochemical processes. Suspended particles trapped on pre-combusted (Hg-free) glass- or quartz-fiber filters are analyzed for total mercury (THg), MeHg, and reactive divalent mercury. Filtrates are analyzed for THg and MeHg to approximate the dissolved fraction. The sum of concentrations in particulate and filtrate fractions represents whole water, equivalent to an unfiltered sample. This approach improves upon analysis of filtered and unfiltered samples and computation of particulate concentration by difference; volume filtered is adjusted based on suspended-sediment concentration to minimize particulate non-detects. Information from bed-sediment sampling is enhanced by sieving into multiple size fractions and determining detailed grain-size distribution. Wet sieving ensures particle disaggregation; sieve water is retained and fines are recovered by centrifugation. Speciation analysis by sequential extraction and examination of heavy mineral concentrates by scanning electron microscopy provide additional information regarding Hg mineralogy and geochemistry. Biomagnification of MeHg in food webs is tracked using phytoplankton, zooplankton, aquatic and emergent vegetation, invertebrates, fish, and birds. Analysis of zooplankton in multiple size fractions from multiple depths in reservoirs can provide insight into food-web dynamics. The presentation will highlight application of these methods in several Hg-contaminated watersheds, with emphasis on understanding seasonal variability in designing effective sampling strategies.
Corsi, Steven R.; Borchardt, Mark A.; Carvin, Rebecca B.; Burch, Tucker R; Spencer, Susan K.; Lutz, Michelle A.; McDermott, Colleen M.; Busse, Kimberly M.; Kleinheinz, Gregory; Feng, Xiaoping; Zhu, Jun
2016-01-01
Waterborne pathogens were measured at three beaches in Lake Michigan, environmental factors for predicting pathogen concentrations were identified, and the risk of swimmer infection and illness was estimated. Waterborne pathogens were detected in 96% of samples collected at three Lake Michigan beaches in summer, 2010. Samples were quantified for 22 pathogens in four microbial categories (human viruses, bovine viruses, protozoa, and pathogenic bacteria). All beaches had detections of human and bovine viruses and pathogenic bacteria indicating influence of multiple contamination sources at these beaches. Occurrence ranged from 40 to 87% for human viruses, 65–87% for pathogenic bacteria, and 13–35% for bovine viruses. Enterovirus, adenovirus A, Salmonella spp., Campylobacter jejuni, bovine polyomavirus, and bovine rotavirus A were present most frequently. Variables selected in multiple regression models used to explore environmental factors that influence pathogens included wave direction, cloud cover, currents, and water temperature. Quantitative Microbial Risk Assessment was done for C. jejuni, Salmonella spp., and enteroviruses to estimate risk of infection and illness. Median infection risks for one-time swimming events were approximately 3 × 10–5, 7 × 10–9, and 3 × 10–7 for C. jejuni, Salmonella spp., and enteroviruses, respectively. Results highlight the importance of investigating multiple pathogens within multiple categories to avoid underestimating the prevalence and risk of waterborne pathogens.
Zhang, Huimin; He, Hongkui; Yu, Xiujuan; Xu, Zhaohui; Zhang, Zhizhou
2016-11-01
It remains an unsolved problem to quantify a natural microbial community by rapidly and conveniently measuring multiple species with functional significance. Most widely used high throughput next-generation sequencing methods can only generate information mainly for genus-level taxonomic identification and quantification, and detection of multiple species in a complex microbial community is still heavily dependent on approaches based on near full-length ribosome RNA gene or genome sequence information. In this study, we used near full-length rRNA gene library sequencing plus Primer-Blast to design species-specific primers based on whole microbial genome sequences. The primers were intended to be specific at the species level within relevant microbial communities, i.e., a defined genomics background. The primers were tested with samples collected from the Daqu (also called fermentation starters) and pit mud of a traditional Chinese liquor production plant. Sixteen pairs of primers were found to be suitable for identification of individual species. Among them, seven pairs were chosen to measure the abundance of microbial species through quantitative PCR. The combination of near full-length ribosome RNA gene library sequencing and Primer-Blast may represent a broadly useful protocol to quantify multiple species in complex microbial population samples with species-specific primers.
Unsupervised Ensemble Anomaly Detection Using Time-Periodic Packet Sampling
NASA Astrophysics Data System (ADS)
Uchida, Masato; Nawata, Shuichi; Gu, Yu; Tsuru, Masato; Oie, Yuji
We propose an anomaly detection method for finding patterns in network traffic that do not conform to legitimate (i.e., normal) behavior. The proposed method trains a baseline model describing the normal behavior of network traffic without using manually labeled traffic data. The trained baseline model is used as the basis for comparison with the audit network traffic. This anomaly detection works in an unsupervised manner through the use of time-periodic packet sampling, which is used in a manner that differs from its intended purpose — the lossy nature of packet sampling is used to extract normal packets from the unlabeled original traffic data. Evaluation using actual traffic traces showed that the proposed method has false positive and false negative rates in the detection of anomalies regarding TCP SYN packets comparable to those of a conventional method that uses manually labeled traffic data to train the baseline model. Performance variation due to the probabilistic nature of sampled traffic data is mitigated by using ensemble anomaly detection that collectively exploits multiple baseline models in parallel. Alarm sensitivity is adjusted for the intended use by using maximum- and minimum-based anomaly detection that effectively take advantage of the performance variations among the multiple baseline models. Testing using actual traffic traces showed that the proposed anomaly detection method performs as well as one using manually labeled traffic data and better than one using randomly sampled (unlabeled) traffic data.
Abdallah, Mohamed F; Girgin, Gözde; Baydar, Terken; Krska, Rudolf; Sulyok, Michael
2017-10-01
The present study aimed to investigate the occurrence of multiple toxic fungal and bacterial metabolites in 156 animal feed (n = 77) and maize (n = 79) samples collected from three regions in Upper Egypt. The target analytes were quantified using the 'dilute and shoot' approach, followed by a liquid chromatography tandem mass spectrometry analysis. In total, 115 fungal and bacterial metabolites were detected in both matrices, including the regulated mycotoxins in the European Union, in addition to the modified forms such as deoxynivalenol-3-glucosid. Furthermore, some Fusarium, Alternaria, Aspergillus and Penicillum metabolites beside other fungal and bacterial metabolites were detected for the first time in Egypt. All of the samples were contaminated with at least four toxins. On average, 26 different metabolites were detected per sample with a trend of more metabolites in feed than in maize. The maximum number of analytes observed per samples was 54 analytes at maximum concentrations ranging from 0.04 µg kg -1 for tentoxin to 25 040 µg kg -1 for kojic acid. According to the international standards, the contamination rates in the investigated regions were not alarming, except for AFB1 in maize. The necessity of further and continuous monitoring is highly recommended to establish a database for mycotoxin occurrence. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Tully, B. J.; Heidelberg, J. F.; Kraft, B.; Girguis, P. R.; Huber, J. A.
2016-12-01
The oceanic crust contains the largest aquifer on Earth with a volume approximately 2% of the global ocean. Ongoing research at the North Pond (NP) site, west of the Mid-Atlantic Ridge, provides an environment representative of oxygenated crustal aquifers beneath oligotrophic surface waters. Using subseafloor CORK observatories for multiple sampling depths beneath the seafloor, crustal fluids were sampled along the predicted aquifer fluid flow path over a two-year period. DNA was extracted and sequenced for metagenomic analysis from 22 crustal fluid samples, along with the overlying bottom. At broad taxonomic groupings, the aquifer system is highly dynamic over time and space, with shifts in dominant taxa and "blooms" of transient groups that appear at discreet time points and sample depths. We were able to reconstruct 194 high-quality, low-contamination bacterial and archaeal metagenomic-assembled genomes (MAGs) with estimated completeness >50% (429 MAGs >20% complete). Environmental genomes were assigned to phylogenies from the major bacterial phyla, putative novel groups, and poorly sampled phylogenetic groups, including the Marinimicrobia, Candidate Phyla Radiation, and Planctomycetes. Biogeochemically relevant processes were assigned to MAGs, including denitrification, dissimilatory sulfur and hydrogen cycling, and carbon fixation. Collectively, the oxic NP aquifer system represents a diverse, dynamic microbial habitat with the metabolic potential to impact multiple globally relevant biogeochemical cycles, including nitrogen, sulfur, and carbon.
A short working distance multiple crystal x-ray spectrometer
Dickinson, B.; Seidler, G.T.; Webb, Z.W.; Bradley, J.A.; Nagle, K.P.; Heald, S.M.; Gordon, R.A.; Chou, I.-Ming
2008-01-01
For x-ray spot sizes of a few tens of microns or smaller, a millimeter-sized flat analyzer crystal placed ???1 cm from the sample will exhibit high energy resolution while subtending a collection solid angle comparable to that of a typical spherically bent crystal analyzer (SBCA) at much larger working distances. Based on this observation and a nonfocusing geometry for the analyzer optic, we have constructed and tested a short working distance (SWD) multicrystal x-ray spectrometer. This prototype instrument has a maximum effective collection solid angle of 0.14 sr, comparable to that of 17 SBCA at 1 m working distance. We find good agreement with prior work for measurements of the Mn K?? x-ray emission and resonant inelastic x-ray scattering for MnO, and also for measurements of the x-ray absorption near-edge structure for Dy metal using L??2 partial-fluorescence yield detection. We discuss future applications at third- and fourth-generation light sources. For concentrated samples, the extremely large collection angle of SWD spectrometers will permit collection of high-resolution x-ray emission spectra with a single pulse of the Linac Coherent Light Source. The range of applications of SWD spectrometers and traditional multi-SBCA instruments has some overlap, but also is significantly complementary. ?? 2008 American Institute of Physics.
Zhang, Jiajing; Watson, Gregory S.; Watson, Jolanta A.; Han, Dong
2018-01-01
Although the cicada wing has a variety of functions and the nanostructure and surface properties of many species have been extensively investigated, there are no reports investigating diversity of nanostructures and wetting properties within a single species collected at locations with different rainfall conditions. In this study, the hydrophobicity and nanostructure dimensions of the forewing surface of Cryptotympana atrata were measured, based on specimens collected from 12 distributions with varying precipitation averages in China and Japan. The relationships among hydrophobicity, nanostructures, and precipitation were analyzed, and the adaption of hydrophobic nanostructures under different wet environments is discussed. The precipitation of locations in the years the samples of C. atrata were collected only has an effect on the diameter and spacing of wing surface nanostructure, and the multiple years of precipitation may have an influence on the basic diameter and spacing, as well as the height of protrusions. The rougher the wing surface, the stronger the hydrophobicity which was observed from samples taken where the rainfall conditions of the collection years are high. To our knowledge, this is one special example providing evidence of hydrophobic nanostructures found on a biological surface of a single species which shows adaption for specific wet environments. PMID:29849761
NASA Astrophysics Data System (ADS)
Campbell, T. L.; Geller, J. B.; Heller, P.; Ruiz, G.; Chang, A.; McCann, L.; Ceballos, L.; Marraffini, M.; Ashton, G.; Larson, K.; Havard, S.; Meagher, K.; Wheelock, M.; Drake, C.; Rhett, G.
2016-02-01
The Ballast Water Management Act, the Marine Invasive Species Act, and the Coastal Ecosystem Protection Act require the California Department of Fish and Wildlife to monitor and evaluate the extent of biological invasions in the state's marine and estuarine waters. This has been performed statewide, using a variety of methodologies. Conventional sample collection and processing is laborious, slow and costly, and may require considerable taxonomic expertise requiring detailed time-consuming microscopic study of multiple specimens. These factors limit the volume of biomass that can be searched for introduced species. New technologies continue to reduce the cost and increase the throughput of genetic analyses, which become efficient alternatives to traditional morphological analysis for identification, monitoring and surveillance of marine invasive species. Using next-generation sequencing of mitochondrial Cytochrome c oxidase subunit I (COI) and nuclear large subunit ribosomal RNA (LSU), we analyzed over 15,000 individual marine invertebrates collected in Californian waters. We have created sequence databases of California native and non-native species to assist in molecular identification and surveillance in North American waters. Metagenetics, the next-generation sequencing of environmental samples with comparison to DNA sequence databases, is a faster and cost-effective alternative to individual sample analysis. We have sequenced from biomass collected from whole settlement plates and plankton in California harbors, and used our introduced species database to create species lists. We can combine these species lists for individual marinas with collected environmental data, such as temperature, salinity, and dissolved oxygen to understand the ecology of marine invasions. Here we discuss high throughput sampling, sequencing, and COASTLINE, our data analysis answer to challenges working with hundreds of millions of sequencing reads from tens of thousands of specimens.
Testing Collective Memory: Representing the Soviet Union on Multiple-Choice Questions
ERIC Educational Resources Information Center
Reich, Gabriel A.
2011-01-01
This article tests the assumption that state-mandated multiple-choice history exams are a cultural tool for disseminating an "official" collective memory. Findings from a qualitative study of a collection of multiple-choice questions that relate to the history of the Soviet Union are presented. The 263 questions all come from New York…
Ingala, Melissa R.; Simmons, Nancy B.; Wultsch, Claudia; Krampis, Konstantinos; Speer, Kelly A.; Perkins, Susan L.
2018-01-01
The gut microbiome is a community of host-associated symbiotic microbes that fulfills multiple key roles in host metabolism, immune function, and tissue development. Given the ability of the microbiome to impact host fitness, there is increasing interest in studying the microbiome of wild animals to better understand these communities in the context of host ecology and evolution. Human microbiome research protocols are well established, but wildlife microbiome research is still a developing field. Currently, there is no standardized set of best practices guiding the collection of microbiome samples from wildlife. Gut microflora are typically sampled either by fecal collection, rectal swabbing, or by destructively sampling the intestinal contents of the host animal. Studies rarely include more than one sampling technique and no comparison of these methods currently exists for a wild mammal. Although some studies have hypothesized that the fecal microbiome is a nested subset of the intestinal microbiome, this hypothesis has not been formally tested. To address these issues, we examined guano (feces) and distal intestinal mucosa from 19 species of free-ranging bats from Lamanai, Belize, using 16S rRNA amplicon sequencing to compare microbial communities across sample types. We found that the diversity and composition of intestine and guano samples differed substantially. In addition, we conclude that signatures of host evolution are retained by studying gut microbiomes based on mucosal tissue samples, but not fecal samples. Conversely, fecal samples retained more signal of host diet than intestinal samples. These results suggest that fecal and intestinal sampling methods are not interchangeable, and that these two microbiotas record different information about the host from which they are isolated. PMID:29765359
Ingala, Melissa R; Simmons, Nancy B; Wultsch, Claudia; Krampis, Konstantinos; Speer, Kelly A; Perkins, Susan L
2018-01-01
The gut microbiome is a community of host-associated symbiotic microbes that fulfills multiple key roles in host metabolism, immune function, and tissue development. Given the ability of the microbiome to impact host fitness, there is increasing interest in studying the microbiome of wild animals to better understand these communities in the context of host ecology and evolution. Human microbiome research protocols are well established, but wildlife microbiome research is still a developing field. Currently, there is no standardized set of best practices guiding the collection of microbiome samples from wildlife. Gut microflora are typically sampled either by fecal collection, rectal swabbing, or by destructively sampling the intestinal contents of the host animal. Studies rarely include more than one sampling technique and no comparison of these methods currently exists for a wild mammal. Although some studies have hypothesized that the fecal microbiome is a nested subset of the intestinal microbiome, this hypothesis has not been formally tested. To address these issues, we examined guano (feces) and distal intestinal mucosa from 19 species of free-ranging bats from Lamanai, Belize, using 16S rRNA amplicon sequencing to compare microbial communities across sample types. We found that the diversity and composition of intestine and guano samples differed substantially. In addition, we conclude that signatures of host evolution are retained by studying gut microbiomes based on mucosal tissue samples, but not fecal samples. Conversely, fecal samples retained more signal of host diet than intestinal samples. These results suggest that fecal and intestinal sampling methods are not interchangeable, and that these two microbiotas record different information about the host from which they are isolated.
Doidge, James C
2018-02-01
Population-based cohort studies are invaluable to health research because of the breadth of data collection over time, and the representativeness of their samples. However, they are especially prone to missing data, which can compromise the validity of analyses when data are not missing at random. Having many waves of data collection presents opportunity for participants' responsiveness to be observed over time, which may be informative about missing data mechanisms and thus useful as an auxiliary variable. Modern approaches to handling missing data such as multiple imputation and maximum likelihood can be difficult to implement with the large numbers of auxiliary variables and large amounts of non-monotone missing data that occur in cohort studies. Inverse probability-weighting can be easier to implement but conventional wisdom has stated that it cannot be applied to non-monotone missing data. This paper describes two methods of applying inverse probability-weighting to non-monotone missing data, and explores the potential value of including measures of responsiveness in either inverse probability-weighting or multiple imputation. Simulation studies are used to compare methods and demonstrate that responsiveness in longitudinal studies can be used to mitigate bias induced by missing data, even when data are not missing at random.
Comparison of Wipe Materials and Wetting Agents for Pesticide Residue Collection from Hard Surfaces
Deziel, Nicole C.; Viet, Susan M.; Rogers, John W.; Camann, David E.; Marker, David A.; Heikkinen, Maire S. A.; Yau, Alice Y.; Stout, Daniel M.; Dellarco, Michael
2011-01-01
Different wipe materials and wetting agents have been used to collect pesticide residues from surfaces, but little is known about their comparability. To inform the selection of a wipe for the National Children’s Study, the analytical feasibility, collection efficiency, and precision of Twillwipes wetted with isopropanol (TI), Ghost Wipes (GW), and Twillwipes wetted with water (TW), and were evaluated. Wipe samples were collected from stainless steel surfaces spiked with high and low concentrations of 27 insecticides, including organochlorines, organophosphates, and pyrethroids. Samples were analyzed by GC/MS/SIM. No analytical interferences were observed for any of the wipes. The mean percent collection efficiencies across all pesticides for the TI, GW, and TW were 69.3%, 31.1%, and 10.3% at the high concentration, respectively, and 55.6%, 22.5%, and 6.9% at the low concentration, respectively. The collection efficiencies of the TI were significantly greater than that of GW or TW (p<0.0001). Collection efficiency also differed significantly by pesticide (p<0.0001) and spike concentration (p<0.0001). The pooled coefficients of variation (CVs) of the collection efficiencies for the TI, GW, and TW at high concentration were 0.08, 0.17, and 0.24, respectively. The pooled CV of the collection efficiencies for the TI, GW, and TW at low concentration were 0.15, 0.19, and 0.36, respectively. The TI had significantly lower CVs than either of the other two wipes (p=0.0008). Though the TI was superior in terms of both accuracy and precision, it requires multiple preparation steps, which could lead to operational challenges in a large-scale study. PMID:21816452
Entangling measurements for multiparameter estimation with two qubits
NASA Astrophysics Data System (ADS)
Roccia, Emanuele; Gianani, Ilaria; Mancino, Luca; Sbroscia, Marco; Somma, Fabrizia; Genoni, Marco G.; Barbieri, Marco
2018-01-01
Careful tailoring the quantum state of probes offers the capability of investigating matter at unprecedented precisions. Rarely, however, the interaction with the sample is fully encompassed by a single parameter, and the information contained in the probe needs to be partitioned on multiple parameters. There exist, then, practical bounds on the ultimate joint-estimation precision set by the unavailability of a single optimal measurement for all parameters. Here, we discuss how these considerations are modified for two-level quantum probes — qubits — by the use of two copies and entangling measurements. We find that the joint estimation of phase and phase diffusion benefits from such collective measurement, while for multiple phases no enhancement can be observed. We demonstrate this in a proof-of-principle photonics setup.
Combining Search Engines for Comparative Proteomics
Tabb, David
2012-01-01
Many proteomics laboratories have found spectral counting to be an ideal way to recognize biomarkers that differentiate cohorts of samples. This approach assumes that proteins that differ in quantity between samples will generate different numbers of identifiable tandem mass spectra. Increasingly, researchers are employing multiple search engines to maximize the identifications generated from data collections. This talk evaluates four strategies to combine information from multiple search engines in comparative proteomics. The “Count Sum” model pools the spectra across search engines. The “Vote Counting” model combines the judgments from each search engine by protein. Two other models employ parametric and non-parametric analyses of protein-specific p-values from different search engines. We evaluated the four strategies in two different data sets. The ABRF iPRG 2009 study generated five LC-MS/MS analyses of “red” E. coli and five analyses of “yellow” E. coli. NCI CPTAC Study 6 generated five concentrations of Sigma UPS1 spiked into a yeast background. All data were identified with X!Tandem, Sequest, MyriMatch, and TagRecon. For both sample types, “Vote Counting” appeared to manage the diverse identification sets most effectively, yielding heightened discrimination as more search engines were added.
Biopsychosocial correlates of lifetime major depression in a multiple sclerosis population.
Patten, S B; Metz, L M; Reimer, M A
2000-04-01
The objective of this paper was to evaluate the lifetime and point prevalence of major depression in a population-based Multiple Sclerosis (MS) clinic sample, and to describe associations between selected biopsychosocial variables and the prevalence of lifetime major depression in this sample. Subjects who had participated in an earlier study were re-contacted for additional data collection. Eighty-three per cent (n=136) of those eligible consented to participate. Each subject completed the Composite International Diagnostic Interview (CIDI) and an interviewer-administered questionnaire evaluating a series of biopsychosocial variables. The lifetime prevalence of major depression in this sample was 22.8%, somewhat lower than previous estimates in MS clinic populations. Women, those under 35, and those with a family history of major depression had a higher prevalence. Also, subjects reporting high levels of stress and heavy ingestion of caffeine (>400 mg) had a higher prevalence of major depression. As this was a cross-sectional analysis, the direction of causal effect for the observed associations could not be determined. By identifying variables that are associated with lifetime major depression, these data generate hypotheses for future prospective studies. Such studies will be needed to further understand the etiology of depressive disorders in MS.
Chromatographic analysis of tryptophan metabolites
Sadok, Ilona; Gamian, Andrzej
2017-01-01
The kynurenine pathway generates multiple tryptophan metabolites called collectively kynurenines and leads to formation of the enzyme cofactor nicotinamide adenine dinucleotide. The first step in this pathway is tryptophan degradation, initiated by the rate‐limiting enzymes indoleamine 2,3‐dioxygenase, or tryptophan 2,3‐dioxygenase, depending on the tissue. The balanced kynurenine metabolism, which has been a subject of multiple studies in last decades, plays an important role in several physiological and pathological conditions such as infections, autoimmunity, neurological disorders, cancer, cataracts, as well as pregnancy. Understanding the regulation of tryptophan depletion provide novel diagnostic and treatment opportunities, however it requires reliable methods for quantification of kynurenines in biological samples with complex composition (body fluids, tissues, or cells). Trace concentrations, interference of sample components, and instability of some tryptophan metabolites need to be addressed using analytical methods. The novel separation approaches and optimized extraction protocols help to overcome difficulties in analyzing kynurenines within the complex tissue material. Recent developments in chromatography coupled with mass spectrometry provide new opportunity for quantification of tryptophan and its degradation products in various biological samples. In this review, we present current accomplishments in the chromatographic methodologies proposed for detection of tryptophan metabolites and provide a guide for choosing the optimal approach. PMID:28590049
Ortiz, Roderick F.; Stogner, Sr., Robert W.
2001-01-01
A comprehensive sampling network was implemented in the Alamosa River Basin from 1995 to 1997 to address data gaps identified as part of the ecological risk assessment of the Summitville Superfund site. Aluminum, copper, iron, and zinc were identified as the constituents of concern for the risk assessment. Water-quality samples were collected at six sites on the Alamosa River and Wightman Fork by automatic samplers. Several discrete (instantaneous) samples were collected over 24 hours at each site during periods of high diurnal variations in streamflow (May through September). The discrete samples were analyzed individually and duplicate samples were composited to produce a single sample that represented the daily-mean concentration. The diurnal variations in concentration with respect to the theoretical daily-mean concentration (maximum minus minimum divided by daily mean) are presented. Diurnal metal concentrations were highly variable in the Alamosa River and Wightman Fork. The concentration of a metal at a single site could change by several hundred percent during one diurnal cycle. The largest percent change in metal concentrations was observed for aluminum and iron. Zinc concentrations varied the least of the four metals. No discernible or predictable pattern was indicated in the timing of the daily mean, maximum, or minimum concentrations. The percentage of discrete sample concentrations that varied from the daily-mean concentration by thresholds of plus or minus 10, 25, and 50 percent was evaluated. Between 50 and 75 percent of discrete-sample concentrations varied from the daily-mean concentration by more than plus or minus 10 percent. The percentage of samples exceeding given thresholds generally was smaller during the summer period than the snowmelt period. Sampling strategies are critical to accurately define variability in constituent concentration, and conversely, understanding constituent variability is important in determining appropriate sampling strategies. During nonsteady-state periods, considerable errors in estimates of daily-mean concentration are possible if based on one discrete sample. Flow-weighting multiple discrete samples collected over a diurnal cycle provides a better estimate of daily-mean concentrations during nonsteady-state periods.
Hannett, George E.; Stone, Ward B.; Davis, Stephen W.; Wroblewski, Danielle
2011-01-01
The genetic relatedness of Clostridium botulinum type E isolates associated with an outbreak of wildlife botulism was studied using random amplification of polymorphic DNA (RAPD). Specimens were collected from November 2000 to December 2008 during a large outbreak of botulism affecting birds and fish living in and around Lake Erie and Lake Ontario. In our present study, a total of 355 wildlife samples were tested for the presence of botulinum toxin and/or organisms. Type E botulinum toxin was detected in 110 samples from birds, 12 samples from fish, and 2 samples from mammals. Sediment samples from Lake Erie were also examined for the presence of C. botulinum. Fifteen of 17 sediment samples were positive for the presence of C. botulinum type E. Eighty-one C. botulinum isolates were obtained from plants, animals, and sediments; of these isolates, 44 C. botulinum isolates produced type E toxin, as determined by mouse bioassay, while the remaining 37 isolates were not toxic for mice. All toxin-producing isolates were typed by RAPD; that analysis showed 12 different RAPD types and multiple subtypes. Our study thus demonstrates that multiple genetically distinct strains of C. botulinum were involved in the present outbreak of wildlife botulism. We found that C. botulinum type E is present in the sediments of Lake Erie and that a large range of bird and fish species is affected. PMID:21115703
Analyte variations in consecutive 24-hour urine collections in children.
Ellison, Jonathan S; Hollingsworth, John M; Langman, Craig B; Asplin, John R; Schwaderer, Andrew L; Yan, Phyllis; Bierlein, Maggie; Barraza, Mark A; Defoor, William R; Figueroa, T Ernesto; Jackson, Elizabeth C; Jayanthi, Venkata R; Johnson, Emilie K; Joseph, David B; Shnorhavorian, Margarett
2017-12-01
The metabolic evaluation of children with nephrolithiasis begins with a 24-h urine collection. For adults, the diagnostic yield increases with consecutive collections; however, little is known regarding the variability of multiple 24-h studies in the pediatric population. We sought to evaluate the variability of consecutive 24-h urine collection in children through a multi-institutional study hypothesizing that compared with a single collection, consecutive 24-h urine collections would reveal a greater degree of clinically useful information in the evaluation of children at risk for nephrolithiasis. Including data from six institutions, we identified children less than 18 years of age considered at risk for recurrent nephrolithiasis, undergoing metabolic evaluation. We evaluated a subset of patients performing two collections with urine creatinine varying by 10% or less during a 7-day period. Discordance between repeat collections based on normative urine chemistry values was evaluated. A total of 733 children met inclusion criteria, and in over a third both urine calcium and urine volume differed by 30% or more between samples. Urine oxalate demonstrated greater variation between collections in children <5 years than among older children (p = 0.030) while variation in other parameters did not differ by age. Discordance between repeat samples based on normative values was most common for urine oxalate (22.5%) and the derived relative supersaturation ratios for both calcium phosphate (25.1%) and calcium oxalate (20.5%). The proportion of discordant samples, based on normative thresholds, as well as variability greater ≥30% and 50%, respectively, are shown in the table. Our analysis indicates that stone risk in as many as one in four children may be misclassified if normative values of only a single 24-h urine are used. In light of these findings, repeat 24-h urine collections prior to targeted intervention to modify stone risk are advised to increase diagnostic yield in children at risk for nephrolithiasis. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Eikenberry, Barbara C. Scudder; Bell, Amanda H.; Olds, Hayley T.; Burns, Daniel J.
2016-07-25
Recent data are lacking to assess whether impairments still exist at four of Wisconsin’s largest Lake Michigan harbors that were designated as Areas of Concern (AOCs) in the late 1980s due to sediment contamination and multiple Beneficial Use Impairments (BUIs), such as those affecting benthos (macroinvertebrates) and plankton (zooplankton and phytoplankton) communities. During three seasonal sampling events (“seasons”) in May through August 2012, the U.S. Geological Survey collected sediment benthos and water plankton at the four AOCs as well as six less-degraded non-AOCs along the western Lake Michigan shoreline to assess whether AOC communities were degraded in comparison to non-AOC communities. The four AOCs are the Lower Menominee River, the Lower Green Bay and Fox River, the Sheboygan River, and the Milwaukee Estuary. Due to their size and complexity, multiple locations or “subsites” were sampled within the Lower Green Bay and Fox River AOC (Lower Green Bay, the Fox River near Allouez, and the Fox River near De Pere) and within the Milwaukee Estuary AOC (the Milwaukee River, the Menomonee River, and the Milwaukee Harbor) and single locations were sampled at the other AOCs and non-AOCs. The six non-AOCs are the Escanaba River in Michigan, and the Oconto River, Ahnapee River, Kewaunee River, Manitowoc River, and Root River in Wisconsin. Benthos samples were collected by using Hester-Dendy artificial substrates deployed for 30 days and by using a dredge sampler; zooplankton were collected by net and phytoplankton by whole-water sampler. Except for the Lower Green Bay and Milwaukee Harbor locations, communities at each AOC were compared to all non-AOCs as a group and to paired non-AOCs using taxa relative abundances and metrics, including richness, diversity, and an Index of Biotic Integrity (IBI, for Hester-Dendy samples only). Benthos samples collected during one or more seasons were rated as degraded for at least one metric at all AOCs. In the Milwaukee Estuary, benthos richness was lower in the Milwaukee River subsite spring and summer samples and in the Menomonee River subsite spring sample relative to the paired non-AOCs. Benthos diversity and IBIs at the Menomonee River subsite and IBIs at the Milwaukee River subsite and Sheboygan River were significantly lower than at all non-AOCs as a group across all seasons and therefore were rated as degraded. In addition, IBIs at the Lower Menominee River were significantly lower than those at the paired non-AOCs during all seasons and were therefore rated degraded. Benthos at both Fox River subsites and the Milwaukee River subsite were significantly different from their paired non-AOCs during all three seasons, based on a comparison of the relative abundances of taxa using multivariate testing. Metrics for plankton at AOCs were not significantly lower than those at the paired or group non-AOCs during all seasons; however, zooplankton richness in spring at the Sheboygan River and in fall at the Menomonee River subsite was rated as degraded in comparison to paired non-AOCs. Also, zooplankton richness in fall at the Fox River near Allouez subsite and in spring at the Milwaukee River subsite was rated degraded overall because values were lower than at all non-AOCs as a group and lower than at the paired non-AOCs. Zooplankton diversity in fall at the Fox River near Allouez subsite and the Lower Menominee River was rated degraded in comparison to paired non-AOC comparison sites. Zooplankton communities at the Fox River near Allouez subsite were significantly different from the paired non-AOCs when multivariate comparisons were made without rotifers other than A. priodonta. Overall, benthos and zooplankton BUIs remained at the AOCs in 2012 but no AOCs with a phytoplankton BUI were rated degraded in comparison to non-AOCs. The use of a multiple ecological measures, structural and functional, and multiple statistical analyses, biological metrics and multivariate statistics, provided assessments that defined 2012 status of communities relative to less-impaired non-AOCs in the Great Lakes area.
NASA Technical Reports Server (NTRS)
Eigenbrode, J. L.; Glavin, D.; Coll, P.; Summons, R. E.; Mahaffy, P.; Archer, D.; Brunner, A.; Conrad, P.; Freissinet, C.; Martin, M.;
2013-01-01
key challenge in assessing the habitability of martian environments is the detection of organic matter - a requirement of all life as we know it. The Curiosity rover, which landed on August 6, 2012 in Gale Crater of Mars, includes the Sample Analysis at Mars (SAM) instrument suite capable of in situ analysis of gaseous organic components thermally evolved from sediment samples collected, sieved, and delivered by the MSL rover. On Sol 94, SAM received its first solid sample: scooped sediment from Rocknest that was sieved to <150 m particle size. Multiple 10-40 mg portions of the scoop #5 sample were delivered to SAM for analyses. Prior to their introduction, a blank (empty cup) analysis was performed. This blank served 1) to clean the analytical instrument of SAMinternal materials that accumulated in the gas processing system since integration into the rover, and 2) to characterize the background signatures of SAM. Both the blank and the Rocknest samples showed the presence of hydrocarbon components.
Freeman, Christine M; Crudgington, Sean; Stolberg, Valerie R; Brown, Jeanette P; Sonstein, Joanne; Alexis, Neil E; Doerschuk, Claire M; Basta, Patricia V; Carretta, Elizabeth E; Couper, David J; Hastie, Annette T; Kaner, Robert J; O'Neal, Wanda K; Paine, Robert; Rennard, Stephen I; Shimbo, Daichi; Woodruff, Prescott G; Zeidler, Michelle; Curtis, Jeffrey L
2015-01-27
Subpopulations and Intermediate Outcomes in COPD Study (SPIROMICS) is a multi-center longitudinal, observational study to identify novel phenotypes and biomarkers of chronic obstructive pulmonary disease (COPD). In a subset of 300 subjects enrolled at six clinical centers, we are performing flow cytometric analyses of leukocytes from induced sputum, bronchoalveolar lavage (BAL) and peripheral blood. To minimize several sources of variability, we use a "just-in-time" design that permits immediate staining without pre-fixation of samples, followed by centralized analysis on a single instrument. The Immunophenotyping Core prepares 12-color antibody panels, which are shipped to the six Clinical Centers shortly before study visits. Sputum induction occurs at least two weeks before a bronchoscopy visit, at which time peripheral blood and bronchoalveolar lavage are collected. Immunostaining is performed at each clinical site on the day that the samples are collected. Samples are fixed and express shipped to the Immunophenotyping Core for data acquisition on a single modified LSR II flow cytometer. Results are analyzed using FACS Diva and FloJo software and cross-checked by Core scientists who are blinded to subject data. Thus far, a total of 152 sputum samples and 117 samples of blood and BAL have been returned to the Immunophenotyping Core. Initial quality checks indicate useable data from 126 sputum samples (83%), 106 blood samples (91%) and 91 BAL samples (78%). In all three sample types, we are able to identify and characterize the activation state or subset of multiple leukocyte cell populations (including CD4+ and CD8+ T cells, B cells, monocytes, macrophages, neutrophils and eosinophils), thereby demonstrating the validity of the antibody panel. Our study design, which relies on bi-directional communication between clinical centers and the Core according to a pre-specified protocol, appears to reduce several sources of variability often seen in flow cytometric studies involving multiple clinical sites. Because leukocytes contribute to lung pathology in COPD, these analyses will help achieve SPIROMICS aims of identifying subgroups of patients with specific COPD phenotypes. Future analyses will correlate cell-surface markers on a given cell type with smoking history, spirometry, airway measurements, and other parameters. This study was registered with ClinicalTrials.gov as NCT01969344 .
Overmyer, Katherine A.; Thonusin, Chanisa; Qi, Nathan R.; Burant, Charles F.; Evans, Charles R.
2015-01-01
A critical application of metabolomics is the evaluation of tissues, which are often the primary sites of metabolic dysregulation in disease. Laboratory rodents have been widely used for metabolomics studies involving tissues due to their facile handing, genetic manipulability and similarity to most aspects of human metabolism. However, the necessary step of administration of anesthesia in preparation for tissue sampling is not often given careful consideration, in spite of its potential for causing alterations in the metabolome. We examined, for the first time using untargeted and targeted metabolomics, the effect of several commonly used methods of anesthesia and euthanasia for collection of skeletal muscle, liver, heart, adipose and serum of C57BL/6J mice. The data revealed dramatic, tissue-specific impacts of tissue collection strategy. Among many differences observed, post-euthanasia samples showed elevated levels of glucose 6-phosphate and other glycolytic intermediates in skeletal muscle. In heart and liver, multiple nucleotide and purine degradation metabolites accumulated in tissues of euthanized compared to anesthetized animals. Adipose tissue was comparatively less affected by collection strategy, although accumulation of lactate and succinate in euthanized animals was observed in all tissues. Among methods of tissue collection performed pre-euthanasia, ketamine showed more variability compared to isoflurane and pentobarbital. Isoflurane induced elevated liver aspartate but allowed more rapid initiation of tissue collection. Based on these findings, we present a more optimal collection strategy mammalian tissues and recommend that rodent tissues intended for metabolomics studies be collected under anesthesia rather than post-euthanasia. PMID:25658945
Overmyer, Katherine A; Thonusin, Chanisa; Qi, Nathan R; Burant, Charles F; Evans, Charles R
2015-01-01
A critical application of metabolomics is the evaluation of tissues, which are often the primary sites of metabolic dysregulation in disease. Laboratory rodents have been widely used for metabolomics studies involving tissues due to their facile handing, genetic manipulability and similarity to most aspects of human metabolism. However, the necessary step of administration of anesthesia in preparation for tissue sampling is not often given careful consideration, in spite of its potential for causing alterations in the metabolome. We examined, for the first time using untargeted and targeted metabolomics, the effect of several commonly used methods of anesthesia and euthanasia for collection of skeletal muscle, liver, heart, adipose and serum of C57BL/6J mice. The data revealed dramatic, tissue-specific impacts of tissue collection strategy. Among many differences observed, post-euthanasia samples showed elevated levels of glucose 6-phosphate and other glycolytic intermediates in skeletal muscle. In heart and liver, multiple nucleotide and purine degradation metabolites accumulated in tissues of euthanized compared to anesthetized animals. Adipose tissue was comparatively less affected by collection strategy, although accumulation of lactate and succinate in euthanized animals was observed in all tissues. Among methods of tissue collection performed pre-euthanasia, ketamine showed more variability compared to isoflurane and pentobarbital. Isoflurane induced elevated liver aspartate but allowed more rapid initiation of tissue collection. Based on these findings, we present a more optimal collection strategy mammalian tissues and recommend that rodent tissues intended for metabolomics studies be collected under anesthesia rather than post-euthanasia.
van Ginkel, Joost H; van den Broek, Daan A; van Kuik, Joyce; Linders, Dorothé; de Weger, Roel; Willems, Stefan M; Huibers, Manon M H
2017-10-01
In current molecular cancer diagnostics, using blood samples of cancer patients for the detection of genetic alterations in plasma (cell-free) circulating tumor DNA (ctDNA) is an emerging practice. Since ctDNA levels in blood are low, highly sensitive Droplet Digital PCR (ddPCR) can be used for detecting rare mutational targets. In order to perform ddPCR on blood samples, a standardized procedure for processing and analyzing blood samples is necessary to facilitate implementation into clinical practice. Therefore, we assessed the technical sample workup procedure for ddPCR on blood plasma samples. Blood samples from healthy individuals, as well as lung cancer patients were analyzed. We compared different methods and protocols for sample collection, storage, centrifugation, isolation, and quantification. Cell-free DNA (cfDNA) concentrations of several wild-type targets and BRAF and EGFR-mutant ctDNA concentrations quantified by ddPCR were primary outcome measurements. Highest cfDNA concentrations were measured in blood collected in serum tubes. No significant differences in cfDNA concentrations were detected between various time points of up to 24 h until centrifugation. Highest cfDNA concentrations were detected after DNA isolation with the Quick cfDNA Serum & Plasma Kit, while plasma isolation using the QIAamp Circulating Nucleic Acid Kit yielded the most consistent results. DdPCR results on cfDNA are highly dependent on multiple factors during preanalytical sample workup, which need to be addressed during the development of this diagnostic tool for cancer diagnostics in the future. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Choi, Sungshin; Ray, Hami E; Lai, San-Huei; Alwood, Joshua S; Globus, Ruth K
2016-01-01
Even with recent scientific advancements, challenges posed by limited resources and capabilities at the time of sample dissection continue to limit the collection of high quality tissues from experiments that can be conducted only infrequently and at high cost, such as in space. The resources and time it takes to harvest tissues post-euthanasia, and the methods and duration of long duration storage, potentially have negative impacts on sample quantity and quality, thereby limiting the scientific outcome that can be achieved. The goals of this study were to optimize methods for both sample recovery and science return from rodent experiments, with possible relevance to both ground based and spaceflight studies. The first objective was to determine the impacts of tissue harvest time post-euthanasia, preservation methods, and storage duration, focusing on RNA quality and enzyme activities in liver and spleen as indices of sample quality. The second objective was to develop methods that will maximize science return by dissecting multiple tissues after long duration storage in situ at -80°C. Tissues of C57Bl/6J mice were dissected and preserved at various time points post-euthanasia and stored at -80°C for up to 11 months. In some experiments, tissues were recovered from frozen carcasses which had been stored at -80°C up to 7 months. RNA quantity and quality was assessed by measuring RNA Integrity Number (RIN) values using an Agilent Bioanalyzer. Additionally, the quality of tissues was assessed by measuring activities of hepatic enzymes (catalase, glutathione reductase and GAPDH). Fresh tissues were collected up to one hour post-euthanasia, and stored up to 11 months at -80°C, with minimal adverse effects on the RNA quality of either livers or RNAlater-preserved spleens. Liver enzyme activities were similar to those of positive controls, with no significant effect observed at any time point. Tissues dissected from frozen carcasses that had been stored for up to 7 months at -80°C had variable results, depending on the specific tissue analyzed. RNA quality of liver, heart, and kidneys were minimally affected after 6-7 months of storage at -80°C, whereas RNA degradation was evident in tissues such as small intestine, bone, and bone marrow when they were collected from the carcasses frozen for 2.5 months. These results demonstrate that 1) the protocols developed for spaceflight experiments with on-orbit dissections support the retrieval of high quality samples for RNA expression and some protein analyses, despite delayed preservation post-euthanasia or prolonged storage, and 2) many additional tissues for gene expression analysis can be obtained by dissection even following prolonged storage of the tissue in situ at -80°C. These findings have relevance both to high value, ground-based experiments when sample collection capability is severely constrained, and to spaceflight experiments that entail on-orbit sample recovery by astronauts.
Sun, Rui; Dama, James F; Tan, Jeffrey S; Rose, John P; Voth, Gregory A
2016-10-11
Metadynamics is an important enhanced sampling technique in molecular dynamics simulation to efficiently explore potential energy surfaces. The recently developed transition-tempered metadynamics (TTMetaD) has been proven to converge asymptotically without sacrificing exploration of the collective variable space in the early stages of simulations, unlike other convergent metadynamics (MetaD) methods. We have applied TTMetaD to study the permeation of drug-like molecules through a lipid bilayer to further investigate the usefulness of this method as applied to problems of relevance to medicinal chemistry. First, ethanol permeation through a lipid bilayer was studied to compare TTMetaD with nontempered metadynamics and well-tempered metadynamics. The bias energies computed from various metadynamics simulations were compared to the potential of mean force calculated from umbrella sampling. Though all of the MetaD simulations agree with one another asymptotically, TTMetaD is able to predict the most accurate and reliable estimate of the potential of mean force for permeation in the early stages of the simulations and is robust to the choice of required additional parameters. We also show that using multiple randomly initialized replicas allows convergence analysis and also provides an efficient means to converge the simulations in shorter wall times and, more unexpectedly, in shorter CPU times; splitting the CPU time between multiple replicas appears to lead to less overall error. After validating the method, we studied the permeation of a more complicated drug-like molecule, trimethoprim. Three sets of TTMetaD simulations with different choices of collective variables were carried out, and all converged within feasible simulation time. The minimum free energy paths showed that TTMetaD was able to predict almost identical permeation mechanisms in each case despite significantly different definitions of collective variables.
Protein crystallography prescreen kit
Segelke, Brent W.; Krupka, Heike I.; Rupp, Bernhard
2007-10-02
A kit for prescreening protein concentration for crystallization includes a multiplicity of vials, a multiplicity of pre-selected reagents, and a multiplicity of sample plates. The reagents and a corresponding multiplicity of samples of the protein in solutions of varying concentrations are placed on sample plates. The sample plates containing the reagents and samples are incubated. After incubation the sample plates are examined to determine which of the sample concentrations are too low and which the sample concentrations are too high. The sample concentrations that are optimal for protein crystallization are selected and used.
Protein crystallography prescreen kit
Segelke, Brent W.; Krupka, Heike I.; Rupp, Bernhard
2005-07-12
A kit for prescreening protein concentration for crystallization includes a multiplicity of vials, a multiplicity of pre-selected reagents, and a multiplicity of sample plates. The reagents and a corresponding multiplicity of samples of the protein in solutions of varying concentrations are placed on sample plates. The sample plates containing the reagents and samples are incubated. After incubation the sample plates are examined to determine which of the sample concentrations are too low and which the sample concentrations are too high. The sample concentrations that are optimal for protein crystallization are selected and used.
Dehghani, Ali; Dehghan Nayeri, Nahid; Ebadi, Abbas
2017-01-01
ABSTRACT Background: Due to many physical and mental disorders that occur in multiple sclerosis patients, identifying the factors affecting coping based on the experiences of patients using qualitative study is essential to improve their quality of life. This study was conducted to explore the antecedents of coping with the disease in patients with multiple sclerosis. Methods: This is a qualitative study conducted on 11 patients with multiple sclerosis in 2015 in Tehran, Iran. These patients were selected based on purposive sampling. Data were collected using semi-structured and in-depth interviews and coded. These data were analyzed using the conventional content analysis. The rigor of qualitative data using the criteria proposed by Guba and Lincoln were assessed. Results: Five main categories were revealed: (1) social support, (2) lenience, (3) reliance on faith, (4) knowledge of multiple sclerosis and modeling, and (5) economic and environmental situation. Each category had several distinct sub-categories. Conclusions: The results of this study showed that coping with multiple sclerosis is a complex, multidimensional and contextual concept that is affected by various factors in relation to the context of Iran. The findings of the study can provide the healthcare professionals with deeper recognition and understanding of these antecedents to improve successful coping in Iranian patients suffering from multiple sclerosis. PMID:28097178
Rasmussen, Teresa J.; Paxson, Chelsea R.
2017-08-25
Municipalities in Johnson County in northeastern Kansas are required to implement stormwater management programs to reduce pollutant discharges, protect water quality, and comply with applicable water-quality regulations in accordance with National Pollutant Discharge Elimination System permits for stormwater discharge. To this end, municipalities collect grab samples at streams entering and leaving their jurisdiction to determine levels of excessive nutrients, sediment, and fecal bacteria to characterize pollutants and understand the factors affecting them.In 2014, the U.S. Geological Survey and the Johnson County Stormwater Management Program, with input from the Kansas Department of Health and Environment, initiated a 5-year monitoring program to satisfy minimum sampling requirements for each municipality as described by new stormwater permits issued to Johnson County municipalities. The purpose of this report is to provide a preliminary assessment of the monitoring program. The monitoring program is described, a preliminary assessment of the monitoring program design is provided using water-quality data collected during the first 2 years of the program, and the ability of the current monitoring network and sampling plan to provide data sufficient to quantify improvements in water quality resulting from implemented and planned best management practices is evaluated. The information in this initial report may be used to evaluate changes in data collection methods while data collection is still ongoing that may lead to improved data utility.Discrete water-quality samples were collected at 27 sites and analyzed for nutrients, Escherichia coli (E. coli) bacteria, total suspended solids, and suspended-sediment concentration. In addition, continuous water-quality data (water temperature, pH, dissolved oxygen, specific conductance, turbidity, and nitrate plus nitrite) were collected at one site to characterize variability and provide a basis for comparison to discrete data. Base flow samples indicated that point sources are likely affecting nutrient concentrations and E. coli bacteria densities at several sites. Concentrations of all analytes in storm runoff samples were characterized by substantial variability among sites and samples. About one-half of the sites, representing different watersheds, had storm runoff samples with nitrogen concentrations greater than 10 milligrams per liter. About one-third of the sites, representing different watersheds, had storm runoff samples with total phosphorus concentrations greater than 3 milligrams per liter. Six sites had samples with E. coli densities greater than 100,000 colonies per 100 milliliters of water. Total suspended solids concentrations of about 12,000 milligrams per liter or greater occurred in samples from three sites.Data collected for this monitoring program may be useful for some general assessment purposes but may also be limited in potential to fully inform stormwater management activities. Valuable attributes of the monitoring program design included incorporating many sites across the county for comparisons among watersheds and municipalities, using fixed-stage samplers to collect multiple samples during single events, collection of base flow samples in addition to storm samples to isolate possible point sources from stormwater sources, and use of continuous monitors to characterize variability. Limiting attributes of the monitoring program design included location of monitoring sites along municipal boundaries to satisfy permit requirements rather than using watershed-based criteria such as locations of tributaries, potential pollutant sources, and implemented management practices. Additional limiting attributes include having a large number of widespread sampling locations, which presented logistical challenges for predicting localized rainfall and collecting and analyzing samples during short timeframes associated with storms, and collecting storm samples at fixed-stage elevations only during the rising limb of storms, which does not characterize conditions over the storm hydrograph. The small number of samples collected per site resulted in a sample size too small to be representative of site conditions, including seasonal and hydrologic variability, and insufficient for meaningful statistical analysis or site-specific modeling.Several measures could be taken to improve data utility and include redesigning the monitoring network according to watershed characteristics, incorporating a nested design in which data are collected at different scales (watershed, subwatershed, and best management practices), increasing sampling frequency, and combining different methods to allow for flexibility to focus on areas and conditions of particular interest. A monitoring design that would facilitate most of these improvements would be to focus efforts on a limited number of watersheds for several years, then cycle to the next set of watersheds for several years, eventually returning to previously monitored watersheds to document changes.Redesign of the water-quality monitoring program requires considerable effort and commitment from municipalities of Johnson County. However, the long-term benefit likely is a monitoring program that results in improved stream conditions and more effective management practices and efficient expenditure of resources.
Simmons, Johanna; Wijma, Barbro; Swahnberg, Katarina
2015-09-28
Lifetime co-occurrence of violence victimisation is common. A large proportion of victims report being exposed to multiple forms of violence (physical, sexual, emotional violence) and/or violence by multiple kinds of perpetrators (family members, intimate partners, acquaintances/strangers). Yet much research focuses on only one kind of victimisation. The aim of this study was to investigate the association between symptoms of psychological ill health, and A) exposure to multiple forms of violence, and B) violence by multiple perpetrators. Secondary analysis of cross-sectional data previously collected for prevalence studies on interpersonal violence in Sweden was used. Respondents were recruited at hospital clinics (women n = 2439, men n = 1767) and at random from the general population (women n = 1168, men n = 2924). Multinomial regression analysis was used to estimate associations between exposure to violence and symptoms of psychological ill health. Among both men and women and in both clinical and population samples, exposure to multiple forms of violence as well as violence by multiple perpetrators were more strongly associated with symptoms of psychological ill health than reporting one form of violence or violence by one perpetrator. For example, in the female population sample, victims reporting all three forms of violence were four times more likely to report many symptoms of psychological ill health compared to those reporting only one form of violence (adj OR: 3.8, 95 % CI 1.6-8.8). In the male clinical sample, victims reporting two or three kind of perpetrators were three times more likely to report many symptoms of psychological ill health than those reporting violence by one perpetrator (adj OR 3.3 95 % CI 1.9-5.9). The strong association found between lifetime co-occurrence of violence victimisation and symptoms of psychological ill-health is important to consider in both research and clinic work. If only the effect of one form of violence or violence by one kind of perpetrator is considered this may lead to a misinterpretation of the association between violence and psychological ill health. When the effect of unmeasured traumata is ignored, the full burden of violence experienced by victims may be underestimated. Different kinds of victimisation can work interactively, making exposure to multiple forms of violence as well as violence by multiple perpetrators more strongly associated with symptoms of psychological ill health than any one kind of victimisation alone.
Optimizing Urine Processing Protocols for Protein and Metabolite Detection.
Siddiqui, Nazema Y; DuBois, Laura G; St John-Williams, Lisa; Will, Thompson J; Grenier, Carole; Burke, Emily; Fraser, Matthew O; Amundsen, Cindy L; Murphy, Susan K
In urine, factors such as timing of voids, and duration at room temperature (RT) may affect the quality of recovered protein and metabolite data. Additives may aid with detection, but can add more complexity in sample collection or analysis. We aimed to identify the optimal urine processing protocol for clinically-obtained urine samples that allows for the highest protein and metabolite yields with minimal degradation. Healthy women provided multiple urine samples during the same day. Women collected their first morning (1 st AM) void and another "random void". Random voids were aliquotted with: 1) no additive; 2) boric acid (BA); 3) protease inhibitor (PI); or 4) both BA + PI. Of these aliquots, some were immediately stored at 4°C, and some were left at RT for 4 hours. Proteins and individual metabolites were quantified, normalized to creatinine concentrations, and compared across processing conditions. Sample pools corresponding to each processing condition were analyzed using mass spectrometry to assess protein degradation. Ten Caucasian women between 35-65 years of age provided paired 1 st morning and random voided urine samples. Normalized protein concentrations were slightly higher in 1 st AM compared to random "spot" voids. The addition of BA did not significantly change proteins, while PI significantly improved normalized protein concentrations, regardless of whether samples were immediately cooled or left at RT for 4 hours. In pooled samples, there were minimal differences in protein degradation under the various conditions we tested. In metabolite analyses, there were significant differences in individual amino acids based on the timing of the void. For comparative translational research using urine, information about void timing should be collected and standardized. For urine samples processed in the same day, BA does not appear to be necessary while the addition of PI enhances protein yields, regardless of 4°C or RT storage temperature.
Hoard, C.J.; Holtschlag, D.J.; Duris, J.W.; James, D.A.; Obenauer, D.J.
2012-01-01
In 2009, the Michigan Department of Environmental Quality and the U.S. Geological Survey developed a plan to compare the effect of various streamgaging and water-quality collection techniques on streamflow and stream water-quality data for the Saginaw River, Michigan. The Saginaw River is the primary contributor of surface runoff to Saginaw Bay, Lake Huron, draining approximately 70 percent of the Saginaw Bay watershed. The U.S. Environmental Protection Agency has listed the Saginaw Bay system as an "Area of Concern" due to many factors, including excessive sediment and nutrient concentrations in the water. Current efforts to estimate loading of sediment and nutrients to Saginaw Bay utilize water-quality samples collected using a surface-grab technique and flow data that are uncertain during specific conditions. Comparisons of current flow and water-quality sampling techniques to alternative techniques were assessed between April 2009 and September 2009 at two locations in the Saginaw River. Streamflow estimated using acoustic Doppler current profiling technology was compared to a traditional stage-discharge technique. Complex conditions resulting from the influence of Saginaw Bay on the Saginaw River were able to be captured using the acoustic technology, while the traditional stage-discharge technique failed to quantify these effects. Water-quality samples were collected at two locations and on eight different dates, utilizing both surface-grab and depth-integrating multiple-vertical techniques. Sixteen paired samples were collected and analyzed for suspended sediment, turbidity, total phosphorus, total nitrogen, orthophosphate, nitrite, nitrate, and ammonia. Results indicate that concentrations of constituents associated with suspended material, such as suspended sediment, turbidity, and total phosphorus, are underestimated when samples are collected using the surface-grab technique. The median magnitude of the relative percent difference in concentration based on sampling technique was 37 percent for suspended sediment, 26 percent for turbidity, and 9.7 percent for total phosphorus samples collected at both. Acoustic techniques were also used to assist in the determination of the effectiveness of using acoustic-backscatter information for estimating the suspended-sediment concentration of the river water. Backscatter data was collected by use of an acoustic Doppler current profiler, and a Van Dorn manual sampler was simultaneously used to collect discrete water samples at 10 depths (3.5, 7.5, 11, 14, 15.5, 17.5, 19.5, 20.5, 22, and 24.5 ft below the water surface) along two vertical profiles near the center of the Saginaw River near Bay City. The Van Dorn samples were analyzed for suspended-sediment concentrations, and these data were then used to develop a relationship between acoustic-backscatter data. Acoustic-backscatter data was strongly correlated to sediment concentrations and, by using a linear regression, was able to explain 89 percent of the variability. Although this regression technique showed promise for using acoustic backscatter to estimate suspended-sediment concentration, attempts to compare suspended-sediment concentrations to the acoustic signal-to-noise ratio estimates, recorded at the fixed acoustic streamflow-gaging station near Bay City (04157061), resulted in a poor correlation.
In-Situ Operations and Planning for the Mars Science Laboratory Robotic Arm: The First 200 Sols
NASA Technical Reports Server (NTRS)
Robinson, M.; Collins, C.; Leger, P.; Carsten, J.; Tompkins, V.; Hartman, F.; Yen, J.
2013-01-01
The Robotic Arm (RA) has operated for more than 200 Martian solar days (or sols) since the Mars Science Laboratory rover touched down in Gale Crater on August 5, 2012. During the first seven months on Mars the robotic arm has performed multiple contact science sols including the positioning of the Alpha Particle X-Ray Spectrometer (APXS) and/or Mars Hand Lens Imager (MAHLI) with respect to rocks or loose regolith targets. The RA has supported sample acquisition using both the scoop and drill, sample processing with CHIMRA (Collection and Handling for In- Situ Martian Rock Analysis), and delivery of sample portions to the observation tray, and the SAM (Sample Analysis at Mars) and CHEMIN (Chemistry and Mineralogy) science instruments. This paper describes the planning and execution of robotic arm activities during surface operations, and reviews robotic arm performance results from Mars to date.
Preserving, Enhancing, and Continuing the Scientific Legacy of the Apollo Sample Suite
NASA Astrophysics Data System (ADS)
Zeigler, R. A.; Evans, C. A.; Lehnert, K.; Cai, Y.; Todd, N. S.
2016-12-01
From 1969 to 1972, Apollo astronauts collected 382 kg of rocks, soils, and core samples from six geologically diverse locations on the Moon. In the nearly 50 years since the samples were collected, over 3000 different studies have been conducted using the nearly 2200 different Apollo samples. Despite the maturity of the sample collection, many new studies of lunar samples are undertaken each year, with an average of >55 requests and >600 distinct subsamples allocated annually over the past five years. The Apollo samples are a finite resource, however. Although new studies are encouraged, it is important that new studies do not duplicate previous studies, and where possible, leverage previous results to inform and enhance the current studies. This helps to preserve the samples and scientific funding, both of which are precious resources. We have initiated several new efforts to rescue some of the early analyses from these samples, including unpublished analytical data. We are actively scanning NASA documentation in paper form that is related to the Apollo missions and sample processing, and we are collaborating with IEDA to establish a geochemical data base called MoonDB. To populate this database, we are actively working with about a dozen prominent lunar PIs to organize and transcribe years of both published and unpublished data, making it available to all researchers. This effort will also take advantage of new online analytical tools like PetDB. There have already been tangible results from the MoonDB data rescue effort. A pilot project involving the rescue of geochemical data of John Delano on Apollo pyroclastic glasses has already been referenced in multiple Apollo sample requests, and in fact, the compiled data was used as part of one of the new studies. Similarly, scanned sample handling reports have been utilized to find previously analyzed samples that were appropriate to fulfill new sample requests. We have also begun to image the Apollo samples using (1) micro-CT scanning to document the interior structure of samples, and (2) comprehensive high resolution photography of samples, enabling high resolution 3D reconstructions of the samples. Both efforts will provide comprehensive access to these samples and allow for more targeted requests, and thus better curation of the samples for decades to come.
Preserving, Enhancing, and Continuing the Scientific Legacy of the Apollo Sample Suite
NASA Technical Reports Server (NTRS)
Zeigler, Ryan; Evans, Cindy; Cai, Yue; Lehnert, Kerstin; Todd, Nancy; Blumenfeld, Erika
2016-01-01
From 1969 to 1972, Apollo astronauts collected 382 kg of rocks, soils, and core samples from six geologically diverse locations on the Moon. In the nearly 50 years since the samples were collected, over 3000 different studies have been conducted using the nearly 2200 different Apollo samples. Despite the maturity of the sample collection, many new studies of lunar samples are undertaken each year, with an average of more than 55 requests and more than 600 distinct subsamples allocated annually over the past five years. The Apollo samples are a finite resource, however. Although new studies are encouraged, it is important that new studies do not duplicate previous studies, and where possible, leverage previous results to inform and enhance the current studies. This helps to preserve the samples and scientific funding, both of which are precious resources. We have initiated several new efforts to rescue some of the early analyses from these samples, including unpublished analytical data. We are actively scanning NASA documentation in paper form that is related to the Apollo missions and sample processing, and we are collaborating with IEDA to establish a geochemical data base called MoonDB. To populate this database, we are actively working with about a dozen prominent lunar PIs to organize and transcribe years of both published and unpublished data, making it available to all researchers. This effort will also take advantage of new online analytical tools like PetDB. There have already been tangible results from the MoonDB data rescue effort. A pilot project involving the rescue of geochemical data of John Delano on Apollo pyroclastic glasses has already been referenced in multiple Apollo sample requests, and in fact, the compiled data was used as part of one of the new studies. Similarly, scanned sample handling reports have been utilized to find previously analyzed samples that were appropriate to fulfill new sample requests. We have also begun to image the Apollo samples using (1) micro-CT scanning to document the interior structure of samples, and (2) comprehensive high resolution photography of samples, enabling high resolution 3D reconstructions of the samples. Both efforts will provide comprehensive access to these samples and allow for more targeted requests, and thus better curation of the samples for decades to come.
Ruutel, K; Lohmus, L; Janes, J
2015-04-16
The aim of the current project was to develop an Internet-based recruitment system for HIV and sexually transmitted infection (STI) screening for men who have sex with men (MSM) in Estonia in order to collect biological samples during behavioural studies. In 2013, an Internet-based HIV risk-behaviour survey was conducted among MSM living in Estonia. After completing the questionnaire, all participants were offered anonymous and free-of-charge STI testing. They could either order a urine sample kit by post to screen for chlamydia infections (including lymphogranuloma venereum (LGV)), trichomoniasis, gonorrhoea and Mycoplasma genitalium infections, or visit a laboratory for HIV, hepatitis A virus, hepatitis B virus,hepatitis C virus and syphilis screening. Of 301 participants who completed the questionnaire, 265 (88%),reported that they were MSM. Of these 265 MSM,68 (26%) underwent various types of testing. In the multiple regression analysis, Russian as the first language,previous HIV testing and living in a city or town increased the odds of testing during the study. Linking Internet-based behavioural data collection with biological sample collection is a promising approach. As there are no specific STI services for MSM in Estonia,this system could also be used as an additional option for anonymous and free-of-charge STI screening.
Whiley, Harriet; Keegan, Alexandra; Fallowfield, Howard; Bentham, Richard
2014-01-01
Inhalation of potable water presents a potential route of exposure to opportunistic pathogens and hence warrants significant public health concern. This study used qPCR to detect opportunistic pathogens Legionella spp., L. pneumophila and MAC at multiple points along two potable water distribution pipelines. One used chlorine disinfection and the other chloramine disinfection. Samples were collected four times over the year to provide seasonal variation and the chlorine or chloramine residual was measured during collection. Legionella spp., L. pneumophila and MAC were detected in both distribution systems throughout the year and were all detected at a maximum concentration of 103 copies/mL in the chlorine disinfected system and 106, 103 and 104 copies/mL respectively in the chloramine disinfected system. The concentrations of these opportunistic pathogens were primarily controlled throughout the distribution network through the maintenance of disinfection residuals. At a dead-end and when the disinfection residual was not maintained significant (p < 0.05) increases in concentration were observed when compared to the concentration measured closest to the processing plant in the same pipeline and sampling period. Total coliforms were not present in any water sample collected. This study demonstrates the ability of Legionella spp., L. pneumophila and MAC to survive the potable water disinfection process and highlights the need for greater measures to control these organisms along the distribution pipeline and at point of use. PMID:25046636
Emerging Methods and Systems for Observing Life in the Sea
NASA Astrophysics Data System (ADS)
Chavez, F.; Pearlman, J.; Simmons, S. E.
2016-12-01
There is a growing need for observations of life in the sea at time and space scales consistent with those made for physical and chemical parameters. International programs such as the Global Ocean Observing System (GOOS) and Marine Biodiversity Observation Networks (MBON) are making the case for expanded biological observations and working diligently to prioritize essential variables. Here we review past, present and emerging systems and methods for observing life in the sea from the perspective of maintaining continuous observations over long time periods. Methods that rely on ships with instrumentation and over-the-side sample collections will need to be supplemented and eventually replaced with those based from autonomous platforms. Ship-based optical and acoustic instruments are being reduced in size and power for deployment on moorings and autonomous vehicles. In parallel a new generation of low power, improved resolution sensors are being developed. Animal bio-logging is evolving with new, smaller and more sophisticated tags being developed. New genomic methods, capable of assessing multiple trophic levels from a single water sample, are emerging. Autonomous devices for genomic sample collection are being miniaturized and adapted to autonomous vehicles. The required processing schemes and methods for these emerging data collections are being developed in parallel with the instrumentation. An evolving challenge will be the integration of information from these disparate methods given that each provides their own unique view of life in the sea.
Whiley, Harriet; Keegan, Alexandra; Fallowfield, Howard; Bentham, Richard
2014-07-18
Inhalation of potable water presents a potential route of exposure to opportunistic pathogens and hence warrants significant public health concern. This study used qPCR to detect opportunistic pathogens Legionella spp., L. pneumophila and MAC at multiple points along two potable water distribution pipelines. One used chlorine disinfection and the other chloramine disinfection. Samples were collected four times over the year to provide seasonal variation and the chlorine or chloramine residual was measured during collection. Legionella spp., L. pneumophila and MAC were detected in both distribution systems throughout the year and were all detected at a maximum concentration of 103 copies/mL in the chlorine disinfected system and 106, 103 and 104 copies/mL respectively in the chloramine disinfected system. The concentrations of these opportunistic pathogens were primarily controlled throughout the distribution network through the maintenance of disinfection residuals. At a dead-end and when the disinfection residual was not maintained significant (p < 0.05) increases in concentration were observed when compared to the concentration measured closest to the processing plant in the same pipeline and sampling period. Total coliforms were not present in any water sample collected. This study demonstrates the ability of Legionella spp., L. pneumophila and MAC to survive the potable water disinfection process and highlights the need for greater measures to control these organisms along the distribution pipeline and at point of use.
Industrial Internship and Entrepreneurship Competencies on Vocational High School Students
NASA Astrophysics Data System (ADS)
Wendi, H. F.; Kusumah, I. H.
2018-02-01
The purpose of the research is to explore the influence of internship and vocational skill to student’s entrepreneurship competencies. The research used ex post facto approach. Population in this research is all students of Vocational High School in Bandung, Indonesia. The sample of 40 respondents was determined by proportional random sampling technique. The data were collected by instrument questionnaire and test. Data analysis used descriptive statistics and multiple linear regression. The results show that almost half students have a low the competencies of an entrepreneur. The hypothesis testing shows many the influence of factory teaching has a positive and significant effect on the competencies of an entrepreneur. Similarly, vocational skills have positive influence and significant on the competencies of an entrepreneur. Respectively, the influence of factory teaching and vocational skills expertise collectively have the effect on the competencies of an entrepreneur. Therefore, the influence of factory teaching and vocational skills are effective to student’s entrepreneurship cap competencies.
Recent results from the NA48 experiment at CERN
NASA Astrophysics Data System (ADS)
Shkarovskiy, Sergey; NA48/2 Collaboration
2017-12-01
The NA48/2 experiment presents a final result of the charged kaon semileptonic decays form factors measurement based on 4.28 million Ke3+/- and 2.91 million K{μ3}+/- selected decays collected in 2004. The result is competetive with other measurements in K{μ3}+/- mode and has a smallest uncertainty for Ke3+/- , that leads to the most precise combined Kl3+/- result and allows to reduce the form factor uncertainty of |VUS |. The NA48/2 experiment at CERN collected a very large sample of charged kaon decays into multiple final states. From this data sample we have reconstructed about 1663 events of the very rare decay K ± → μ ± νe + e - over almost negligible background in the region with m(e + e -) above 140 MeV, which is of great interest in Chiral Perturbation Theory. We present the mee spectrum and a model-independent measurement of the decay rate for this region.
AirLab: a cloud-based platform to manage and share antibody-based single-cell research.
Catena, Raúl; Özcan, Alaz; Jacobs, Andrea; Chevrier, Stephane; Bodenmiller, Bernd
2016-06-29
Single-cell analysis technologies are essential tools in research and clinical diagnostics. These methods include flow cytometry, mass cytometry, and other microfluidics-based technologies. Most laboratories that employ these methods maintain large repositories of antibodies. These ever-growing collections of antibodies, their multiple conjugates, and the large amounts of data generated in assays using specific antibodies and conditions makes a dedicated software solution necessary. We have developed AirLab, a cloud-based tool with web and mobile interfaces, for the organization of these data. AirLab streamlines the processes of antibody purchase, organization, and storage, antibody panel creation, results logging, and antibody validation data sharing and distribution. Furthermore, AirLab enables inventory of other laboratory stocks, such as primers or clinical samples, through user-controlled customization. Thus, AirLab is a mobile-powered and flexible tool that harnesses the capabilities of mobile tools and cloud-based technology to facilitate inventory and sharing of antibody and sample collections and associated validation data.
Sherrill, Andrew M; Bell, Kathryn M; Wyngarden, Nicole
2016-07-01
Little is known about intimate partner violence (IPV) victims' situational risk recognition, defined as the ability to identify situational factors that signal imminent risk of victimization. Using semi-structured interviews, qualitative data were collected from a community sample of 31 female victims of IPV episodes involving substance use. Thirteen themes were identified, the most prevalent being related to the partner's verbal behavior, tone of voice, motor behavior, alcohol or drug use, and facial expression. Participants reporting at least some anticipation of physical aggression (61.3% of the sample) tended to identify multiple factors (M = 3.47), suggesting numerous situational features often contribute to situational risk recognition. © The Author(s) 2015.
Al-Jewair, Thikriat; Stellrecht, Elizabeth; Lewandowski, Lauren; Chakaki, Rania
2018-01-01
The American Association of Orthodontists Foundation (AAOF) Craniofacial Growth Legacy Collection is a digital repository of records from 9 craniofacial growth study collections in the United States and Canada. The purposes of this article were to describe the use of materials from the AAOF Craniofacial Growth Legacy Collection in the orthodontic literature in comparative and follow-up studies, and to analyze trends before and after the project's launch in 2009. An electronic search without date or language restriction was conducted in the following databases: PubMed, Embase, Evidence-Based Medicine Reviews, and CINAHL. Grey literature resources and the bibliographies of the selected studies were also consulted. Three independent reviewers assessed the studies for inclusion. The criteria were human subjects of any age, sex, and ethnicity; at least 1 of the 9 AAOF legacy collections used as either the main sample population or the comparison or control; and orthodontic outcomes assessed. Data were analyzed using STATA software (version 14.2; StataCorp, College Station, Tex). A total of 199 studies (127 follow-up, 72 comparative) were included. The most commonly used collection in comparative studies was the Michigan Growth sample. The number of published studies more than doubled after the AAOF Legacy Collection project testing and launch in 2009. The increase continued through 2010 to 2014, during which there was a trend to use multiple collections. The Burlington Growth collection was the most commonly used collection for follow-up studies. The overall use of the legacy collection showed a small increase in published studies after 2009. The overall numbers of published studies in the comparative and follow-up categories increased after 2009, reflecting the efforts of the AAOF team and collection curators to make the records available worldwide. Further research should consider studying each collection to identify utilization predictors. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
The role of wild ruminants in the epidemiology of bovine petechial fever.
Snodgrass, D R; Karstad, L H; Cooper, J E
1975-04-01
After experimental inoculation of Cytoecetes ondiri, the agent of bovine petechial fever (BPF), multiplication occurred in impala, bushbuck, Thomson's gazelles and wildebeest, as shown by infectivity studies and clinical findings. Similar attempts to infect one eland failed. As a sequel to this, blood and spleen samples were collected from four species of wild ruminants in an area where BPTF was endemic. Isolations of C. ondiri were made from three of five bushbuck, but not from any other species.
The role of wild ruminants in the epidemiology of bovine petechial fever.
Snodgrass, D. R.; Karstad, L. H.; Cooper, J. E.
1975-01-01
After experimental inoculation of Cytoecetes ondiri, the agent of bovine petechial fever (BPF), multiplication occurred in impala, bushbuck, Thomson's gazelles and wildebeest, as shown by infectivity studies and clinical findings. Similar attempts to infect one eland failed. As a sequel to this, blood and spleen samples were collected from four species of wild ruminants in an area where BPTF was endemic. Isolations of C. ondiri were made from three of five bushbuck, but not from any other species. PMID:1054728