An oppositely charged insect exclusion screen with gap-free multiple electric fields
NASA Astrophysics Data System (ADS)
Matsuda, Yoshinori; Kakutani, Koji; Nonomura, Teruo; Kimbara, Junji; Kusakari, Shin-ichi; Osamura, Kazumi; Toyoda, Hideyoshi
2012-12-01
An electric field screen was constructed to examine insect attraction mechanisms in multiple electric fields generated inside the screen. The screen consisted of two parallel insulated conductor wires (ICWs) charged with equal but opposite voltages and two separate grounded nets connected to each other and placed on each side of the ICW layer. Insects released inside the fields were charged either positively or negatively as a result of electricity flow from or to the insect, respectively. The force generated between the charged insects and opposite ICW charges was sufficient to capture all insects.
Fatigue failure of regenerator screens in a high frequency Stirling engine
NASA Technical Reports Server (NTRS)
Hull, David R.; Alger, Donald L.; Moore, Thomas J.; Scheuermann, Coulson M.
1988-01-01
Failure of Stirling Space Power Demonstrator Engine (SPDE) regenerator screens was investigated. After several hours of operation the SPDE was shut down for inspection and on removing the regenator screens, debris of unknown origin was discovered along with considerable cracking of the screens in localized areas. Metallurgical analysis of the debris determined it to be cracked-off-deformed pieces of the 41 micron thickness Type 304 stainless steel wire screen. Scanning electron microscopy of the cracked screens revealed failures occurring at wire crossovers and fatigue striations on the fracture surface of the wires. Thus, the screen failure can be characterized as a fatigue failure of the wires. The crossovers were determined to contain 30 percent reduction in wire thickness and a highly worked microstructure occurring from the manufacturing process of the wire screens. Later it was found that reduction in wire thickness occurred because the screen fabricator had subjected it to a light cold-roll process after weaving. Installation of this screen left a clearance in the regenerator allowing the screens to move. The combined effects of the reduction in wire thickness, stress concentration (caused by screen movement), and highly worked microstructure at the wire crossovers led to the fatigue failure of the screens.
Fatigue failure of regenerator screens in a high frequency Stirling engine
NASA Technical Reports Server (NTRS)
Hull, David R.; Alger, Donald L.; Moore, Thomas J.; Scheuermann, Coulson M.
1987-01-01
Failure of Stirling Space Power Demonstrator Engine (SPDE) regenerator screens was investigated. After several hours of operation the SPDE was shut down for inspection and on removing the regenerator screens, debris of unknown origin was discovered along with considerable cracking of the screens in localized areas. Metallurgical analysis of the debris determined it to be cracked-off-deformed pieces of the 41 micron thickness Type 304 stainless steel wire screen. Scanning electron microscopy of the cracked screens revealed failures occurring at wire crossovers and fatigue striations on the fracture surface of the wires. Thus, the screen failure can be characterized as a fatigue failure of the wires. The crossovers were determined to contain a 30 percent reduction in wire thickness and a highly worked microstructure occurring from the manufacturing process of the wire screens. Later it was found that reduction in wire thickness occurred because the screen fabricator had subjected it to a light cold-roll process after weaving. Installation of this screen left a clearance in the regenerator allowing the screens to move. The combined effects of the reduction in wire thickness, stress concentration (caused by screen movement), and highly worked microstructure at the wire crossovers led to the fatigue failure of the screens.
Wire-bending test as a predictor of preclinical performance by dental students.
Kao, E C; Ngan, P W; Wilson, S; Kunovich, R
1990-10-01
Traditional Dental Aptitude Test and academic grade point average have been shown to be poor predictors of clinical performance by dental students. To refine predictors of psychomotor skills, a wire-bending test was given to 105 freshmen at the beginning of their dental education. Grades from seven restorative preclinical courses in their freshman and sophomore years were compared to scores on wire bending and the three traditional predictors: GPA, academic aptitude, and perceptual aptitude scores. Wire-bending scores correlated significantly with six out of seven preclinical restorative courses. The predictive power for preclinical performance was doubled when wire bending was added to traditional predictors in stepwise multiple regression analysis. Wire-bending scores identified students of low performance. These preliminary results suggest that the wire-bending test shows some potential as a screening test for identifying students who may hae psychomotor difficulties, early in their dental education.
Large scale generation of micro-droplet array by vapor condensation on mesh screen piece
Xie, Jian; Xu, Jinliang; He, Xiaotian; Liu, Qi
2017-01-01
We developed a novel micro-droplet array system, which is based on the distinct three dimensional mesh screen structure and sintering and oxidation induced thermal-fluid performance. Mesh screen was sintered on a copper substrate by bonding the two components. Non-uniform residue stress is generated along weft wires, with larger stress on weft wire top location than elsewhere. Oxidation of the sintered package forms micro pits with few nanograsses on weft wire top location, due to the stress corrosion mechanism. Nanograsses grow elsewhere to show hydrophobic behavior. Thus, surface-energy-gradient weft wires are formed. Cooling the structure in a wet air environment nucleates water droplets on weft wire top location, which is more “hydrophilic” than elsewhere. Droplet size is well controlled by substrate temperature, air humidity and cooling time. Because warp wires do not contact copper substrate and there is a larger conductive thermal resistance between warp wire and weft wire, warp wires contribute less to condensation but function as supporting structure. The surface energy analysis of drops along weft wires explains why droplet array can be generated on the mesh screen piece. Because the commercial material is used, the droplet system is cost effective and can be used for large scale utilization. PMID:28054635
Large scale generation of micro-droplet array by vapor condensation on mesh screen piece.
Xie, Jian; Xu, Jinliang; He, Xiaotian; Liu, Qi
2017-01-05
We developed a novel micro-droplet array system, which is based on the distinct three dimensional mesh screen structure and sintering and oxidation induced thermal-fluid performance. Mesh screen was sintered on a copper substrate by bonding the two components. Non-uniform residue stress is generated along weft wires, with larger stress on weft wire top location than elsewhere. Oxidation of the sintered package forms micro pits with few nanograsses on weft wire top location, due to the stress corrosion mechanism. Nanograsses grow elsewhere to show hydrophobic behavior. Thus, surface-energy-gradient weft wires are formed. Cooling the structure in a wet air environment nucleates water droplets on weft wire top location, which is more "hydrophilic" than elsewhere. Droplet size is well controlled by substrate temperature, air humidity and cooling time. Because warp wires do not contact copper substrate and there is a larger conductive thermal resistance between warp wire and weft wire, warp wires contribute less to condensation but function as supporting structure. The surface energy analysis of drops along weft wires explains why droplet array can be generated on the mesh screen piece. Because the commercial material is used, the droplet system is cost effective and can be used for large scale utilization.
Large scale generation of micro-droplet array by vapor condensation on mesh screen piece
NASA Astrophysics Data System (ADS)
Xie, Jian; Xu, Jinliang; He, Xiaotian; Liu, Qi
2017-01-01
We developed a novel micro-droplet array system, which is based on the distinct three dimensional mesh screen structure and sintering and oxidation induced thermal-fluid performance. Mesh screen was sintered on a copper substrate by bonding the two components. Non-uniform residue stress is generated along weft wires, with larger stress on weft wire top location than elsewhere. Oxidation of the sintered package forms micro pits with few nanograsses on weft wire top location, due to the stress corrosion mechanism. Nanograsses grow elsewhere to show hydrophobic behavior. Thus, surface-energy-gradient weft wires are formed. Cooling the structure in a wet air environment nucleates water droplets on weft wire top location, which is more “hydrophilic” than elsewhere. Droplet size is well controlled by substrate temperature, air humidity and cooling time. Because warp wires do not contact copper substrate and there is a larger conductive thermal resistance between warp wire and weft wire, warp wires contribute less to condensation but function as supporting structure. The surface energy analysis of drops along weft wires explains why droplet array can be generated on the mesh screen piece. Because the commercial material is used, the droplet system is cost effective and can be used for large scale utilization.
46 CFR 30.10-25 - Flame screen-TB/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Flame screen—TB/ALL. The term flame screen means a fitted single screen of corrosion-resistant wire of at least 30 by 30 mesh, or two fitted screens, both of corrosion-resistant wire, of at least 20 by 20...
46 CFR 30.10-25 - Flame screen-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Flame screen—TB/ALL. The term flame screen means a fitted single screen of corrosion-resistant wire of at least 30 by 30 mesh, or two fitted screens, both of corrosion-resistant wire, of at least 20 by 20...
Wrinkle-Free Hydroforming of Wire Mesh
NASA Technical Reports Server (NTRS)
Fadness, J.
1986-01-01
Plastic films lubricate workpiece so it deforms smoothly. Thin layers of plastic below top die and above bottom die ensure wire screen slides as shaped by hydroforming. Plastic layers are 0.0043 in. (0.11 m) thick. Preformed to contours of dies and final workpiece. New method of hydroforming fine-wire-mesh heat-shield screens eliminates wrinkles and marks. Prevents screen from being damaged and pores from becoming blocked.
46 CFR 162.017-3 - Materials, construction, and workmanship.
Code of Federal Regulations, 2011 CFR
2011-10-01
...-resistant wire mesh with a 1/2-inch corrosion-resistant separator on a single screen of 30×30 corrosion-resistant wire mesh shall be fitted on all openings to atmosphere. The net free area through the flame... are not acceptable. (e) Flame screens shall be made of corrosion-resistant wire. (f) Nonmetallic...
Outcomes of multiple wire localization for larger breast cancers: when can mastectomy be avoided?
Kirstein, Laurie J; Rafferty, Elizabeth; Specht, Michelle C; Moore, Richard H; Taghian, Alphonse G; Hughes, Kevin S; Gadd, Michele A; Smith, Barbara L
2008-09-01
Mastectomy is often recommended when mammography shows a breast cancer with extensive calcifications. We wished to determine whether the use of multiple localizing wires to guide lumpectomy in this setting was associated with increased rates of breast conservation. We also wanted to identify factors that predicted a poor chance of successful lumpectomy, to avoid multiple lumpectomy attempts in a patient who would ultimately require mastectomy. Records of 153 women with breast cancer who underwent lumpectomy for larger lesions that required multiple wire localization and 196 controls who required only single wire localization were reviewed retrospectively. The number of localizing wires, specimen volume, largest specimen dimension, number of surgical procedures, and rates of breast conservation were scored. Seventy-seven percent of patients requiring multiple wire localization had successful breast conservation, compared with 90% of those needing only single wire localization. Only 28% of multiple wire patients required more than 1 excision to achieve clear margins, compared with 36% of single wire patients (p < 0.01). Breast conservation is possible in the great majority of breast cancer patients whose mammographic lesions require multiple localizing wires for excision. The use of multiple wires can decrease the number of procedures required to obtain clear lumpectomy margins.
1984-03-01
surrounded the rat. The ends of the screen wire tube were twisted and secured with galvanized wire. Care was taken to wrap the screen wire tight so that...function. In N. R. DiLuzio and R. Paoletti (eds.). The reticuloendothelial system and atherosclerosis : Advances in experimental medicine and biology, pp
46 CFR 194.10-25 - Ventilation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... and shall serve no other space. Weather cowls shall be provided with a double layer of wire screen of.... Louvers or weather cowls with a double layer of wire screen of not less than 1/8-inch mesh shall be...
Three dimensional interactive display
NASA Technical Reports Server (NTRS)
Vranish, John M. (Inventor)
2005-01-01
A three-dimensional (3-D) interactive display and method of forming the same, includes a transparent capaciflector (TC) camera formed on a transparent shield layer on the screen surface. A first dielectric layer is formed on the shield layer. A first wire layer is formed on the first dielectric layer. A second dielectric layer is formed on the first wire layer. A second wire layer is formed on the second dielectric layer. Wires on the first wire layer and second wire layer are grouped into groups of parallel wires with a turnaround at one end of each group and a sensor pad at the opposite end. An operational amplifier is connected to each of the sensor pads and the shield pad biases the pads and receives a signal from connected sensor pads in response to intrusion of a probe. The signal is proportional to probe location with respect to the monitor screen.
Optical phonon effect in quasi-one-dimensional semiconductor quantum wires: Band-gap renormalization
NASA Astrophysics Data System (ADS)
Dan, Nguyen Trung; Bechstedt, F.
1996-02-01
We present theoretical studies of dynamical screening in quasi-one-dimensional semiconductor quantum wires including electron-electron and electron-LO-phonon interactions. Within the random-phase approximation we obtain analytical expressions for screened interaction potentials. These expressions can be used to calculate the band-gap renormalization of quantum wires, which depends on the free-carrier density and temperature. We find that the optical phonon interaction effect plays a significant role in band-gap renormalization of quantum wires. The numerical results are compared with some recent experiment measurements as well as available theories.
15. CYLINDRICAL FISH SCALER Remnants of the wire screen remain, ...
15. CYLINDRICAL FISH SCALER Remnants of the wire screen remain, through which the fish tumbled as the cylinder revolved. Note geared ring around cylinder, and the small drive shaft by which it was driven. - Hovden Cannery, 886 Cannery Row, Monterey, Monterey County, CA
Variation with Mach Number of Static and Total Pressures Through Various Screens
NASA Technical Reports Server (NTRS)
Adler, Alfred A
1946-01-01
Tests were conducted in the Langley 24-inch highspeed tunnel to ascertain the static-pressure and total-pressure losses through screens ranging in mesh from 3 to 12 wires per inch and in wire diameter from 0.023 to 0.041 inch. Data were obtained from a Mach number of approximately 0.20 up to the maximum (choking) Mach number obtainable for each screen. The results of this investigation indicate that the pressure losses increase with increasing Mach number until the choking Mach number, which can be computed, is reached. Since choking imposes a restriction on the mass rate of flow and maximum losses are incurred at this condition, great care must be taken in selecting the screen mesh and wire dimmeter for an installation so that the choking Mach number is
Two-Piece Screens for Decontaminating Granular Material
NASA Technical Reports Server (NTRS)
Backes, Douglas; Poulter, Clay; Godfrey, Max; Dutton, Melinda; Tolman, Dennis
2009-01-01
Two-piece screens have been designed specifically for use in filtering a granular material to remove contaminant particles that are significantly wider or longer than are the desired granules. In the original application for which the twopiece screens were conceived, the granular material is ammonium perchlorate and the contaminant particles tend to be wires and other relatively long, rigid strands. The basic design of the twopiece screens can be adapted to other granular materials and contaminants by modifying critical dimensions to accommodate different grain and contaminant- particle sizes. A two-piece screen of this type consists mainly of (1) a top flat plate perforated with circular holes arranged in a hexagonal pattern and (2) a bottom plate that is also perforated with circular holes (but not in a pure hexagonal pattern) and is folded into an accordion structure. Fabrication of the bottom plate begins with drilling circular holes into a flat plate in a hexagonal pattern that is interrupted, at regular intervals, by parallel gaps. The plate is then folded into the accordion structure along the gaps. Because the folds are along the gaps, there are no holes at the peaks and valleys of the accordion screen. The top flat plate and the bottom accordion plate are secured within a metal frame. The resulting two-piece screen is placed at the bottom opening of a feed hopper containing the granular material to be filtered. Tests have shown that such long, rigid contaminant strands as wires readily can pass through a filter consisting of the flat screen alone and that the addition of the accordion screen below the flat screen greatly increases the effectiveness of removal of wires and other contaminant strands. Part of the reason for increased effectiveness is in the presentation of the contaminant to the filter surface. Testing has shown that wire type contamination will readily align itself parallel to the material direction flow. Since this direction of flow is nearly always perpendicular to the filter surface holes, the contamination is automatically aligned to pass through. The two-filter configuration reduces the likelihood that a given contaminant strand will be aligned with the flow of material by eliminating the perpendicular presentation angle. Thus, for wires of a certain diameter, a two-piece screen is 20 percent more effective than is the corresponding flat perforated plate alone, even if the holes in the flat plate are narrower. An accordion screen alone is similarly effective in catching contaminants, but lumps of agglomerated granules of the desired material often collect in the valleys and clog the screen. The addition of a flat screen above the accordion screen prevents clogging of the accordion screen. Flat wire screens have often been used to remove contaminants from granular materials, and are about as effective as are the corresponding perforated flat plates used alone.
Synchronized Re-Entrant Flux Reversal of Multiple FeSiB Amorphous Wires Having the Larger Output
NASA Astrophysics Data System (ADS)
Takajo, Minoru; Yamasaki, Jiro
Technique to synchronize the re-entrant flux reversal of the multiple magnetostrictive Fe77.5Si7.5B15 amorphous wires was developed using a flux keeper of amorphous ribbons contacted to the wire ends. It is comprehended that the characteristics of the re-entrant flux takes place respectively at almost the same time in the three Fe-Si-B amorphous wires with a diameter of 65, 95μm. This phenomenon can be explained by considering the strong magnetic coupling of wires and amorphous ribbon by stray field from the each wire ends. As a result, the magnitude of the induced voltage in the sense coil is increased in proportion to the multiplication of the number of the wires.
Random vibration (stress screening) of printed wiring assemblies
NASA Technical Reports Server (NTRS)
Bastien, Gilbert J.
1988-01-01
The results of a random vibration test screening (RVSS) study of the determination of the upper and lower vibration limits on printed wiring assemblies (PWA) are summarized. The study results are intended to serve as a guide for engineers and designers who make decisions on PWA features that need to withstand the stresses of dynamic testing and screening. The maximum allowable PWA deflection, G levels, and PSD levels are compared to the expected or actual levels to determine if deleterious effects will occur.
Breast surgery techniques: preoperative bracketing wire localization by surgeons.
Burkholder, Hans C; Witherspoon, Laura E; Burns, R Phillip; Horn, Jeffrey S; Biderman, Michael D
2007-06-01
With the development of expertise in image guidance for breast surgery, many surgeons now perform preoperative wire localization themselves. Use of a single wire versus multiple wires to bracket a radiographic breast abnormality has previously been described, although benefits of this technique based on clinical outcomes such as margin status, tissue volume removed, and re-excision rates have not been established. This study is a retrospective analysis of wire-localized breast biopsies performed by 14 surgeons over 29 months; stereotactic and ultrasound guidance were used. During this time, 489 wire localizations were done, of which 159 used multiple wires. Two hundred eleven of these biopsies were done for malignant disease, 86 using multiple wires. After controlling for tumor node metastases stage, single and multiple wire placements were compared using endpoints of margin status, need for re-excision, and total volume of tissue removed. Neither margin status nor re-excision was related to the number of wires placed. However, the number of wires placed was significantly related to the total volume of tissue removed. Use of more than one localizing wire was associated with greater volume of tissue removal (measured in centimeters cubed) in benign disease (46 vs 25, P < 0.001), equivalent volumes in stage 0 disease (73 vs 67), less volume in stage 1 disease (113 vs 164), and less volume in stages 2 through 4 (158 vs 207, P = 0.03). Outcomes based on surgeon case volume during the study period demonstrated that low- (1-40), medium- (41-80), and high-volume (>80) surgeons did not differ in the type or stage of breast pathology treated. Surgeons with high case volumes were more likely to place multiple localizing wires (P < 0.001) and were more likely to do a breast-conserving procedure if re-excision was performed (P < 0.018). Surgeons with low case volumes were more likely to perform a re-excision (P < 0.025). Surgeon experience has a positive impact on quality outcome measures such as performance of a definitive procedure at the time of initial surgery and use of breast-conserving procedures at the time of re-excision. Multiple wire localization can be used to significantly reduce the volume of breast tissue removed in malignant disease without sacrificing margin status or increasing the need for future re-excision.
A nanofabricated wirescanner with free standing wires: Design, fabrication and experimental results
NASA Astrophysics Data System (ADS)
Veronese, M.; Grulja, S.; Penco, G.; Ferianis, M.; Fröhlich, L.; Dal Zilio, S.; Greco, S.; Lazzarino, M.
2018-05-01
Measuring the transverse size of electron beams is of crucial importance in modern accelerators, from large colliders to free electron lasers to storage rings. For this reason several kind of beam instrumentation have been developed such as optical transition radiation screens, scintillating screens, laser scanners and wire scanners. The last ones although providing only a multishot profile in one plane have demonstrated a very high resolution. Wirescanners employ thin wires with typical thickness of the order of tens of microns that are scanned across the beam, whilst ionizing radiation generated from the impact of the electrons with the wires is detected. In this paper we describe a new approach to wirescanners design based on nanofabrication technologies opening new possibilities in term of wire shape, size, material and thickness with potential for sub-micron resolution and increase flexibility for instrumentation designers. We present a device fitted with nanofabricated wires and its fabrication process. We also report the measurements performed on the FERMI FEL electron beam with the goal of providing an online profile measurement without perturbing the FEL.
Microscreen radiation shield for thermoelectric generator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunt, T.K.; Novak, R.F.; McBride, J.R.
1990-08-14
This patent describes a radiation shield adapted to be interposed between a reaction zone and a means for condensing an alkali metal vapor in a thermoelectric generator for converting heat energy directly to electrical energy. The radiation shield comprises woven wire mesh screen, the spacing between the wires forming the mesh screen being such that the radiation shield reflects thermal radiation while permitting the passage of alkali metal vapor therethrough.
Gino, Efrat; Starosvetsky, Jeanna; Kurzbaum, Eyal; Armon, Robert
2010-04-15
Groundwater wells containing large concentrations of ferrous iron face serious clogging problems as a result of biotic iron oxidation. Following a short time after their start off, wells get clogged, and their production efficiency drop significantly up to a total obstruction, making cleanup and rehabilitation an economic burden. The present study was undertaken to test an experimental combined treatment (chemical and biological) for future prevention or rehabilitation of clogged wells. Sphaerotilus natans (an iron-oxidizing bacterium) freshly isolated from a deep well was grown to form biofilms on two systems: coupons and sand buried miniature wedge wire screen baskets. A combined chemical-biological treatment, applied at laboratory scale by use of glycolic acid (2%) and isolated bacteriophages against Sphaerotilus natans (SN1 and ER1-a newly isolated phage) at low multiplicity of infection (MOI), showed inhibition of biofilm formation and inactivation of the contaminant bacteria. In addition to complete inactivation of S. natans planktonic bacteria by the respective phages, earlier biofilm treatment with reduced glycolic acid concentration revealed efficient exopolysaccharide (EPS) digestion allowing phages to be increasingly efficient against biofilm matrix bacteria. Utilization of this combined treatment revealed clean surfaces of a model stainless steel wedge wire screen baskets (commonly used in wells) for up to 60 days.
Screen Channel Liquid Acquisition Devices for Cryogenic Propellants
NASA Technical Reports Server (NTRS)
Chato, David J.; Kudlac, Maureen T.
2005-01-01
This paper describes an on-going project to study the application screen channel liquid acquisition devices to cryogenic propellant systems. The literature of screen liquid acquisition devices is reviewed for prior cryogenic experience. Test programs and apparatus are presented to study these devices. Preliminary results are shown demonstrating bubble points for 200 x 1400 wires per inch and 325 x 2300 wires per inch Dutch twill screens. The 200 x 1400 screen has a bubble point of 15.8 inches of water in isopropyl alcohol and 6.6 inches of water in liquid nitrogen. The 325 x 2300 screen has a bubble point of 24.5 inches of water in isopropyl alcohol, 10.7 inches of water in liquid nitrogen, and 1.83 inches of water in liquid hydrogen. These values are found to be in good agreement with the results reported in the literature.
Interceptive Beam Diagnostics - Signal Creation and Materials Interactions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plum, Michael; Spallation Neutron Source, Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN
2004-11-10
The focus of this tutorial will be on interceptive beam diagnostics such as wire scanners, screens, and harps. We will start with an overview of the various ways beams interact with materials to create signals useful for beam diagnostics systems. We will then discuss the errors in a harp or wire scanner profile measurement caused by errors in wire position, number of samples, and signal errors. Finally we will apply our results to two design examples-the SNS wire scanner system and the SNS target harp.
Heat Transfer Characteristics of Regenerator Matrix (Case of Packed Wire Gauzes)
NASA Technical Reports Server (NTRS)
Hamaguchi, K.; Takahashi, S.; Miyabe, H.
1984-01-01
The average heat transfer coefficient in the matrix of laminated wire screens (10 to 250 mesh) for a Stirling engine heat exchanger was studied experimentally. The data are correlated by N sub ud = 0.42 R sub ed 0.56 (3 or = R sub ed or = 400), and R sub ed are the Nusselt and Reynolds nubmers based on the wire diameter. The pressure drop decreased and the heat transfer increased as the wire diameter was decreased.
Instability of the sliding Luttinger liquid
NASA Astrophysics Data System (ADS)
Fleurov, V.; Kagalovsky, V.; Lerner, I. V.; Yurkevich, I. V.
2018-05-01
We revise a phase diagram for the sliding Luttinger liquid (SLL) of coupled one-dimensional quantum wires packed in two- or three-dimensional arrays in the absence of a magnetic field. We analyse whether physically justifiable (reasonable) inter-wire interactions, i.e. either the screened Coulomb or ‘Coulomb-blockade’ type interactions, stabilise the SLL phase. Calculating the scaling dimensions of the most relevant perturbations (the inter-wire single-particle hybridisation, charge-density wave, and superconducting inter-wire couplings), we find that their combination always destroys the SLL phase for the repulsive intra-wire interaction. However, suppressing the inter-wire tunnelling of repulsive fermions (when the charge-density wave is the only remaining perturbation), one can observe a stability region emerging due to the inter-wire forward scattering interaction.
Experimental verification of a gain reduction model for the space charge effect in a wire chamber
NASA Astrophysics Data System (ADS)
Nagakura, Naoki; Fujii, Kazuki; Harayama, Isao; Kato, Yu; Sekiba, Daiichiro; Watahiki, Yumi; Yamashita, Satoru
2018-01-01
A wire chamber often suffers significant saturation of the multiplication factor when the electric field around its wires is strong. An analytical model of this effect has previously been proposed [Y. Arimoto et al., Nucl. Instrum. Meth. Phys. Res. A 799, 187 (2015)], in which the saturation was described by the multiplication factor, energy deposit density per wire length, and one constant parameter. In order to confirm the validity of this model, a multi-wire drift chamber was developed and irradiated by a MeV-range proton beam at the University of Tsukuba. The saturation effect was compared for energy deposits ranging from 70 keV/cm to 180 keV/cm and multiplication factors 3× 103 to 3× 104. The chamber was rotated with respect to the proton beam in order to vary the space charge density around the wires. The energy deposit distribution corrected for the effect was consistent with the result of a Monte Carlo simulation, thus validating the proposed model.
Plated nickel wire mesh makes superior catalyst bed
NASA Technical Reports Server (NTRS)
Sill, M.
1965-01-01
Porous nickel mesh screen catalyst bed produces gas evolution in hydrogen peroxide thrust chambers used for attitude control of space vehicles. The nickel wire mesh disks in the catalyst bed are plated in rugose form with a silver-gold coating.
Code of Federal Regulations, 2010 CFR
2010-10-01
... only to “unprotected” premises wiring used with simple installations of wiring for up to four line residential and business telephone service. More complex installations of wiring for multiple line services... requirements, for installation and maintenance of wiring on the subscriber's side of the demarcation point...
Vortex Ring Interaction with a Heated Screen
NASA Astrophysics Data System (ADS)
Smith, Jason; Krueger, Paul S.
2008-11-01
Previous examinations of vortex rings impinging on porous screens has shown the reformation of the vortex ring with a lower velocity after passing through the screen, the creation of secondary vortices, and mixing. A heated screen could, in principle, alter the vortex-screen interaction by changing the local liquid viscosity and density. In the present investigation, a mechanical piston-cylinder vortex ring generator was used to create vortex rings in an aqueous sucrose solution. The rings impinged on a screen of horizontal wires that were heated using electrical current. The flow was visualized with food color and video imaging. Tests with and without heat were conducted at a piston stroke-to-jet diameter ratio of 4 and a jet Reynolds number (Re) of 1000. The vortex rings slowed after passing through the screen, but in tests with heat, they maintained a higher fraction of their before-screen velocity due to reduction in fluid viscosity near the wires. In addition, small ``fingers'' that developed on the front of the vortex rings as they passed through the screen exhibited positive buoyancy effects in the heated case.
Intravascular migration of a broken cerclage wire into the left heart.
Leonardi, Francesco; Rivera, Fabrizio
2014-10-01
This article describes a patient in whom a broken cerclage wire migrated from the left hip into the left ventricle. A 71-year-old woman was admitted to the authors' hospital for preoperative examination before femoral hernia repair. Chest radiograph showed a metallic wire in the left ventricle. Twenty-four years earlier, she had a revision arthroplasty. During revision surgery, fragments of the osteotomy were fixed to the femur with multiple cerclage wires. During the past 5 years, radiographic follow-up showed progressive multiple ruptures of cerclage wires. The cerclage wiring was not removed because the patient had no related clinical symptoms. Radiograph of the left hip showed a well-fixed cemented acetabular ring and an uncemented femoral stem with a healed trochanteric osteotomy. All cerclage wires were broken into multiple parts, and it was very difficult to determine which part had migrated into the heart. Thoracic computed tomography scan showed wire that had migrated into the anterior left ventricular myocardial wall at the atrioventricular level. The patient had no clinical symptoms. Electrocardiogram showed a normal sinus rhythm and right bundle branch block. Because of the high risk of surgical left ventriculotomy associated with searching for wire that had migrated into the myocardial wall, patient monitoring was planned. Definitive management of this complication constitutes a dilemma. Although this complication is highly unusual, the possibility of intracardiac migration of broken wire should be considered when deciding on prophylactic surgical removal of hardware after fracture or osteotomy healing. Copyright 2014, SLACK Incorporated.
49 CFR 236.754 - Line, open wire.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Line, open wire. 236.754 Section 236.754 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Line, open wire. An overhead wire line consisting of single conductors as opposed to multiple-conductor...
49 CFR 236.754 - Line, open wire.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Line, open wire. 236.754 Section 236.754 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Line, open wire. An overhead wire line consisting of single conductors as opposed to multiple-conductor...
49 CFR 236.754 - Line, open wire.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Line, open wire. 236.754 Section 236.754 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Line, open wire. An overhead wire line consisting of single conductors as opposed to multiple-conductor...
49 CFR 236.754 - Line, open wire.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Line, open wire. 236.754 Section 236.754 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Line, open wire. An overhead wire line consisting of single conductors as opposed to multiple-conductor...
49 CFR 236.754 - Line, open wire.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Line, open wire. 236.754 Section 236.754 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Line, open wire. An overhead wire line consisting of single conductors as opposed to multiple-conductor...
Current distribution in conducting nanowire networks
NASA Astrophysics Data System (ADS)
Kumar, Ankush; Vidhyadhiraja, N. S.; Kulkarni, Giridhar U.
2017-07-01
Conducting nanowire networks find diverse applications in solar cells, touch-screens, transparent heaters, sensors, and various related transparent conducting electrode (TCE) devices. The performances of these devices depend on effective resistance, transmittance, and local current distribution in these networks. Although, there have been rigorous studies addressing resistance and transmittance in TCE, not much attention is paid on studying the distribution of current. Present work addresses this compelling issue of understanding current distribution in TCE networks using analytical as well as Monte-Carlo approaches. We quantified the current carrying backbone region against isolated and dangling regions as a function of wire density (ranging from percolation threshold to many multiples of threshold) and compared the wired connectivity with those obtained from template-based methods. Further, the current distribution in the obtained backbone is studied using Kirchhoff's law, which reveals that a significant fraction of the backbone (which is believed to be an active current component) may not be active for end-to-end current transport due to the formation of intervening circular loops. The study shows that conducting wire based networks possess hot spots (extremely high current carrying regions) which can be potential sources of failure. The fraction of these hot spots is found to decrease with increase in wire density, while they are completely absent in template based networks. Thus, the present work discusses unexplored issues related to current distribution in conducting networks, which are necessary to choose the optimum network for best TCE applications.
Process for producing fine and ultrafine filament superconductor wire
Kanithi, H.C.
1992-02-18
A process for producing a superconductor wire made up of a large number of round monofilament rods is provided for, comprising assembling a multiplicity of round monofilaments inside each of a multiplicity of thin wall hexagonal tubes and then assembling a number of said thin wall hexagonal tubes within an extrusion can and subsequently consolidating, extruding and drawing the entire assembly down to the desired wire size. 8 figs.
Process for producing fine and ultrafine filament superconductor wire
Kanithi, Hem C.
1992-01-01
A process for producing a superconductor wire made up of a large number of round monofilament rods is provided for, comprising assembling a multiplicity of round monofilaments inside each of a multiplicity of thin wall hexagonal tubes and then assembling a number of said thin wall hexagonal tubes within an extrusion can and subsequently consolidating, extruding and drawing the entire assembly down to the desired wire size.
Detail of the underground wire net mat and cable at ...
Detail of the underground wire net mat and cable at the base of a 94' low-band reflector screen pole, view facing north - U.S. Naval Base, Pearl Harbor, Naval Radio Station, AF/FRD-10 Circularly Disposed Antenna Array, Wahiawa, Honolulu County, HI
NASA Astrophysics Data System (ADS)
Alqadami, Abdulrahman Shueai Mohsen; Jamlos, Mohd Faizal; Soh, Ping Jack; Rahim, Sharul Kamal Abdul; Narbudowicz, Adam
2017-01-01
A compact coplanar waveguide-fed multiple-input multiple-output antenna array based on the left-handed wire loaded spiral resonators (SR) is presented. The proposed antenna consists of a 2 × 2 wire SR with two symmetrical microstrip feed lines, each line exciting a 1 × 2 wire SR. Left-handed metamaterial unit cells are placed on its reverse side and arranged in a 2 × 3 array. A reflection coefficient of less than -16 dB and mutual coupling of less than -28 dB are achieved at 5.15 GHz WLAN band.
46 CFR 30.10-25 - Flame screen-TB/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Flame screen-TB/ALL. 30.10-25 Section 30.10-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS GENERAL PROVISIONS Definitions § 30.10-25 Flame screen—TB/ALL. The term flame screen means a fitted single screen of corrosion-resistant wire of...
46 CFR 30.10-25 - Flame screen-TB/ALL.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Flame screen-TB/ALL. 30.10-25 Section 30.10-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS GENERAL PROVISIONS Definitions § 30.10-25 Flame screen—TB/ALL. The term flame screen means a fitted single screen of corrosion-resistant wire of...
46 CFR 30.10-25 - Flame screen-TB/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Flame screen-TB/ALL. 30.10-25 Section 30.10-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS GENERAL PROVISIONS Definitions § 30.10-25 Flame screen—TB/ALL. The term flame screen means a fitted single screen of corrosion-resistant wire of...
Majewski, Stanislaw; Weisenberger, Andrew G.; Wojcik, Randolph F.; Steinbach, Daniela
1999-01-01
A high resolution gamma ray imaging device includes an aluminum housing, a lead screen collimator at an opened end of the housing, a crystal scintillator array mounted behind the lead screen collimator, a foam layer between the lead screen collimator and the crystal scintillator array, a photomultiplier window coupled to the crystal with optical coupling grease, a photomultiplier having a dynode chain body and a base voltage divider with anodes, anode wire amplifiers each connected to four anodes and a multi pin connector having pin connections to each anode wire amplifier. In one embodiment the crystal scintillator array includes a yttrium aluminum perovskite (YAP) crystal array. In an alternate embodiment, the crystal scintillator array includes a gadolinium oxyorthosilicate (GSO) crystal array.
Josephson junctions of multiple superconducting wires
NASA Astrophysics Data System (ADS)
Deb, Oindrila; Sengupta, K.; Sen, Diptiman
2018-05-01
We study the spectrum of Andreev bound states and Josephson currents across a junction of N superconducting wires which may have s - or p -wave pairing symmetries and develop a scattering matrix based formalism which allows us to address transport across such junctions. For N ≥3 , it is well known that Berry curvature terms contribute to the Josephson currents; we chart out situations where such terms can have relatively large effects. For a system of three s -wave or three p -wave superconductors, we provide analytic expressions for the Andreev bound-state energies and study the Josephson currents in response to a constant voltage applied across one of the wires; we find that the integrated transconductance at zero temperature is quantized to integer multiples of 4 e2/h , where e is the electron charge and h =2 π ℏ is Planck's constant. For a sinusoidal current with frequency ω applied across one of the wires in the junction, we find that Shapiro plateaus appear in the time-averaged voltage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iguchi, Toshihiro, E-mail: iguchi@ba2.so-net.ne.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp
PurposeThe aim of the study was to retrospectively evaluate simultaneous multiple hook wire placement outcomes before video-assisted thoracoscopic surgery (VATS).Materials and MethodsThirty-eight procedures were performed on 35 patients (13 men and 22 women; mean age, 59.9 years) with 80 lung lesions (mean diameter 7.9 mm) who underwent simultaneous multiple hook wire placements for preoperative localizations. The primary endpoints were technical success, complications, procedure duration, and VATS outcome; secondary endpoints included comparisons between technical success rates, complication rates, and procedure durations of the 238 single-placement procedures performed. Complications were also evaluated.ResultsIn 35 procedures including 74 lesions, multiple hook wire placements were technically successful;more » in the remaining three procedures, the second target placement was aborted because of massive pneumothorax after the first placement. Although complications occurred in 34 procedures, no grade 3 or above adverse event was observed. The mean procedure duration was 36.4 ± 11.8 min. Three hook wires dislodged during patient transport to the surgical suite. Seventy-four successfully marked lesions were resected. Six lesions without hook wires were successfully resected after detection by palpation with an additional mini-thoracotomy or using subtle pleural changes as a guide. The complication rates and procedure durations of multiple-placement procedures were significantly higher (P = 0.04) and longer (P < 0.001) than those in the single-placement group, respectively, while the technical success rate was not significantly different (P = 0.051).ConclusionsSimultaneous multiple hook wire placements before VATS were clinically feasible, but increased the complication rate and lengthened the procedure time.« less
Thermal Modeling of the Injection of Standard and Thermally Insulated Cored Wire
NASA Astrophysics Data System (ADS)
Castro-Cedeno, E.-I.; Jardy, A.; Carré, A.; Gerardin, S.; Bellot, J. P.
2017-12-01
Cored wire injection is a widespread method used to perform alloying additions during ferrous and non-ferrous liquid metal treatment. The wire consists of a metal casing that is tightly wrapped around a core of material; the casing delays the release of the material as the wire is immersed into the melt. This method of addition presents advantages such as higher repeatability and yield of cored material with respect to bulk additions. Experimental and numerical work has been performed by several authors on the subject of alloy additions, spherical and cylindrical geometries being mainly considered. Surprisingly this has not been the case for cored wire, where the reported experimental or numerical studies are scarce. This work presents a 1-D finite volume numerical model aimed for the simulation of the thermal phenomena which occurs when the wire is injected into a liquid metal bath. It is currently being used as a design tool for the conception of new types of cored wire. A parametric study on the effect of injection velocity and steel casing thickness for an Al cored wire immersed into a steel melt at 1863 K (1590 °C) is presented. The standard single casing wire is further compared against a wire with multiple casings. Numerical results show that over a certain range of injection velocities, the core contents' release is delayed in the multiple casing when compared to a single casing wire.
46 CFR 162.017-3 - Materials, construction, and workmanship.
Code of Federal Regulations, 2012 CFR
2012-10-01
... corrosion-resistant wire mesh with a 1/2-inch corrosion-resistant separator on a single screen of 30×30 corrosion-resistant wire mesh shall be fitted on all openings to atmosphere. The net free area through the... bronze or such corrosion-resistant material as may be approved by the Commanding Officer, USCG Marine...
46 CFR 162.017-3 - Materials, construction, and workmanship.
Code of Federal Regulations, 2014 CFR
2014-10-01
... corrosion-resistant wire mesh with a 1/2-inch corrosion-resistant separator on a single screen of 30 × 30 corrosion-resistant wire mesh shall be fitted on all openings to atmosphere. The net free area through the... bronze or such corrosion-resistant material as may be approved by the Commanding Officer, USCG Marine...
46 CFR 162.017-3 - Materials, construction, and workmanship.
Code of Federal Regulations, 2013 CFR
2013-10-01
... corrosion-resistant wire mesh with a 1/2-inch corrosion-resistant separator on a single screen of 30 × 30 corrosion-resistant wire mesh shall be fitted on all openings to atmosphere. The net free area through the... bronze or such corrosion-resistant material as may be approved by the Commanding Officer, USCG Marine...
Hydrodynamic parameters of mesh fillers relevant to miniature regenerative cryocoolers
NASA Astrophysics Data System (ADS)
Landrum, E. C.; Conrad, T. J.; Ghiaasiaan, S. M.; Kirkconnell, Carl S.
2010-06-01
Directional hydrodynamic parameters of two fine-mesh porous materials that are suitable for miniature regenerative cryocoolers were studied under steady and oscillating flows of helium. These materials included stacked discs of #635 stainless steel (wire diameter of 20.3 μm) and #325 phosphor bronze (wire diameter of 35.6 μm) wire mesh screens, which are among the commercially available fillers for use in small-scale regenerators and heat exchangers, respectively. Experiments were performed in test sections in which pressure variations across these fillers, in the axial and lateral (radial) directions, were measured under steady and oscillatory flows. The directional permeability and Forchheimer's inertial coefficient were then obtained by using a Computational Fluid Dynamics (CFD)-assisted method. The oscillatory flow experiments covered a frequency range of 50-200 Hz. The results confirmed the importance of anisotropy in the mesh screen fillers, and indicated differences between the directional hydrodynamic resistance parameters for steady and oscillating flow regimes.
Effects of sinker shapes on dissolution profiles.
Soltero, R A; Hoover, J M; Jones, T F; Standish, M
1989-01-01
In dissolution testing, according to the U.S. Pharmacopeia, a nonreactive stainless steel wire helix is typically used to sink dosage forms that would otherwise float. The objective of this investigation was to determine if other sinker shapes will influence the rate, extent, or variability of dissolution. Criteria for the optimal sinker were defined. Various new sinker designs were fabricated, tested, and classified. Four classes of sinker shapes were defined: longitudinal, lateral, screen enclosures, and internal weights. Longitudinal sinkers contact the dosage forms on the long axis. Lateral sinkers either wrap around or contact capsule dosage forms in the middle, such as the line where the top and bottom halves of a capsule shell come together. Screen enclosures are of two types: either a wire cage, which holds the entire capsule, or a circular piece of wire screen placed on top of the capsule. Internal weights consist of two steel ball bearings, one inserted into each end of the capsule. The investigation consisted of four studies: (1) visual observation of the dissolution performance using 12 different sinkers; (2) the effect on drug release from nine classified sinkers on two different capsule formulations; (3) side-by-side comparison between the selected optimal longitudinal U clip and the wire helix lateral type sinkers; and (4) hydrodynamic effects caused by the use of the longitudinal U clip and the wire helix lateral type sinkers in the absence of capsule shells. We concluded that capsules sunk with either of the two longitudinal sinkers, the U clip or the paper clip, have faster, more complete dissolution and less variable results than did lateral type sinkers.(ABSTRACT TRUNCATED AT 250 WORDS)
Zhong, Yan; Xu, Xiao-Quan; Pan, Xiang-Long; Zhang, Wei; Xu, Hai; Yuan, Mei; Kong, Ling-Yan; Pu, Xue-Hui; Chen, Liang; Yu, Tong-Fu
2017-09-01
To evaluate the safety and efficacy of the hook wire system in the simultaneous localizations for multiple pulmonary nodules (PNs) before video-assisted thoracoscopic surgery (VATS), and to clarify the risk factors for pneumothorax associated with the localization procedure. Between January 2010 and February 2016, 67 patients (147 nodules, Group A) underwent simultaneous localizations for multiple PNs using a hook wire system. The demographic, localization procedure-related information and the occurrence rate of pneumothorax were assessed and compared with a control group (349 patients, 349 nodules, Group B). Multivariate logistic regression analyses were used to determine the risk factors for pneumothorax during the localization procedure. All the 147 nodules were successfully localized. Four (2.7%) hook wires dislodged before VATS procedure, but all these four lesions were successfully resected according to the insertion route of hook wire. Pathological diagnoses were acquired for all 147 nodules. Compared with Group B, Group A demonstrated significantly longer procedure time (p < 0.001) and higher occurrence rate of pneumothorax (p = 0.019). Multivariate logistic regression analysis indicated that position change during localization procedure (OR 2.675, p = 0.021) and the nodules located in the ipsilateral lung (OR 9.404, p < 0.001) were independent risk factors for pneumothorax. Simultaneous localizations for multiple PNs using a hook wire system before VATS procedure were safe and effective. Compared with localization for single PN, simultaneous localizations for multiple PNs were prone to the occurrence of pneumothorax. Position change during localization procedure and the nodules located in the ipsilateral lung were independent risk factors for pneumothorax.
Substation alarm multiplexing system (SAMS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
ElBadaly, H.; Gaughan, J.; Ward, G.
1996-03-01
This paper describes an on going R&D project to develop, design, install, and assess the field performance of an advanced substation alarm system. SAMS provides a highly fault-tolerant system for the reporting of equipment alarms. SAMS separates and identifies each of the multiple alarm contacts, transmits an alarm condition over existing substation two-wire system, and displays the alarm source, and its associated technical information, on a touch-screen monitor inside the substation control room, and a remote central location and on a hand held terminal which may be carried anywhere within the substation. SAMS is currently installed at the Sherman Creekmore » substation in the Bronx for the purpose of a three month field evaluation.« less
Detail of 25' highband reflector screen pole showing the horizontal ...
Detail of 25' high-band reflector screen pole showing the horizontal wood beams and vertical wires hung from ceramic insulators, note the dipole antenna element and 94' low-band reflector screen poles in background, view facing north - U.S. Naval Base, Pearl Harbor, Naval Radio Station, AF/FRD-10 Circularly Disposed Antenna Array, Wahiawa, Honolulu County, HI
46 CFR 133.153 - Survival craft launching and recovery arrangements using falls and a winch.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) Each fall wire must be of rotation-resistant and corrosion-resistant steel wire rope. (b) The breaking strength of each fall wire and each attachment used on the fall must be at least six times the load.... (e) Each winch drum must be arranged so the fall wire winds onto the drum in a level wrap. A multiple...
46 CFR 133.153 - Survival craft launching and recovery arrangements using falls and a winch.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Each fall wire must be of rotation-resistant and corrosion-resistant steel wire rope. (b) The breaking strength of each fall wire and each attachment used on the fall must be at least six times the load.... (e) Each winch drum must be arranged so the fall wire winds onto the drum in a level wrap. A multiple...
Detail of 94' lowband reflector screen posts, note the concrete ...
Detail of 94' low-band reflector screen posts, note the concrete curb and vertical wires between posts, view facing north northeast - U.S. Naval Base, Pearl Harbor, Naval Radio Station, AF/FRD-10 Circularly Disposed Antenna Array, Wahiawa, Honolulu County, HI
CAVITATION STUDY OF A PROPELLER OPERATING IN A NONUNIFORM FLOW CREATED BY A WIRE GRID SCREEN.
a given axial wake as produced by a wire mesh with the cavitation in the same wake as reported by van Manen . The second objective was to determine...observed by van Manen except that the intensity varied suggesting that the cavitation index used in the two studies may not be equivalent. (Author)
NASA Technical Reports Server (NTRS)
Linley, Larry
1994-01-01
The objectives of these projects include the following: validate method used to screen wire insulation with arc tracking characteristics; determine damage resistance to arc as a function of source voltage and insulation thickness; investigate propagation characteristics of Kapton at low voltages; and investigate pyrolytic properties of polyimide insulated (Kapton) wire for low voltage (less than 35 VDC) applications. Supporting diagrams and tables are presented.
Detail of 25' highband reflector screen poles with monopole antenna ...
Detail of 25' high-band reflector screen poles with monopole antenna elements behind, note the metal sleeve bases of the reflector screen poles and the guy wire anchors from the dipole antenna elements (left foreground), view facing north northwest - U.S. Naval Base, Pearl Harbor, Naval Radio Station, AF/FRD-10 Circularly Disposed Antenna Array, Wahiawa, Honolulu County, HI
RCS of resonant scatterers with attached wires
NASA Astrophysics Data System (ADS)
Trueman, C. W.; Mishra, S. R.; Kubina, S. J.; Larose, C. L.
1993-03-01
Some aircraft carry wire antennas for HF communication. This paper investigates the effect of such wires on the radar cross section (RCS) at HF frequencies by comparing the RCS of a strip, a cylinder, and a rod with and without an attached wire. The RCS is found for broadside incidence and for end-on incidence of the plane wave for scatterer lengths from 0.4 to 3.8 wavelengths, typical of aircraft size at HF frequencies. It is shown that the RCS of such fuselage-like targets with a wire 'antenna' is quite different from that of the targets without the wire. For broadside incidence, the wire contributes a sharp peak-and-trough to the RCS at the wire's fundamental resonant frequency. For end-on incidence the wire considerably enhances the RCS at frequencies making its length odd multiples of the quarter-wave.
ERIC Educational Resources Information Center
Dutro, Elizabeth; Kantor, Julia
2011-01-01
"The Wire," a critically acclaimed television series on HBO, is one of the latest narratives of urban schools to appear on screen. The series--which unfolded across five seasons and aired its series finale in late 2007--is set in Baltimore and interweaves the stories of inner city residents, particularly a network of characters involved…
46 CFR 119.450 - Vent pipes for fuel tanks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used... installed or equipped to prevent the accidental contamination of the fuel by water under normal operating... flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at...
46 CFR 119.450 - Vent pipes for fuel tanks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used... installed or equipped to prevent the accidental contamination of the fuel by water under normal operating... flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at...
46 CFR 182.450 - Vent pipes for fuel tanks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. Such hose... installed or equipped to prevent the accidental contamination of the fuel by water under normal operating... flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at...
46 CFR 182.450 - Vent pipes for fuel tanks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. Such hose... installed or equipped to prevent the accidental contamination of the fuel by water under normal operating... flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at...
46 CFR 119.450 - Vent pipes for fuel tanks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used... installed or equipped to prevent the accidental contamination of the fuel by water under normal operating... flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at...
46 CFR 119.450 - Vent pipes for fuel tanks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used... installed or equipped to prevent the accidental contamination of the fuel by water under normal operating... flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at...
46 CFR 182.450 - Vent pipes for fuel tanks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. Such hose... installed or equipped to prevent the accidental contamination of the fuel by water under normal operating... flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at...
46 CFR 182.450 - Vent pipes for fuel tanks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. Such hose... installed or equipped to prevent the accidental contamination of the fuel by water under normal operating... flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at...
46 CFR 182.450 - Vent pipes for fuel tanks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. Such hose... installed or equipped to prevent the accidental contamination of the fuel by water under normal operating... flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at...
46 CFR 119.450 - Vent pipes for fuel tanks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used... installed or equipped to prevent the accidental contamination of the fuel by water under normal operating... flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at...
M-plane core-shell InGaN/GaN multiple-quantum-wells on GaN wires for electroluminescent devices.
Koester, Robert; Hwang, Jun-Seok; Salomon, Damien; Chen, Xiaojun; Bougerol, Catherine; Barnes, Jean-Paul; Dang, Daniel Le Si; Rigutti, Lorenzo; de Luna Bugallo, Andres; Jacopin, Gwénolé; Tchernycheva, Maria; Durand, Christophe; Eymery, Joël
2011-11-09
Nonpolar InGaN/GaN multiple quantum wells (MQWs) grown on the {11-00} sidewalls of c-axis GaN wires have been grown by organometallic vapor phase epitaxy on c-sapphire substrates. The structural properties of single wires are studied in detail by scanning transmission electron microscopy and in a more original way by secondary ion mass spectroscopy to quantify defects, thickness (1-8 nm) and In-composition in the wells (∼16%). The core-shell MQW light emission characteristics (390-420 nm at 5 K) were investigated by cathodo- and photoluminescence demonstrating the absence of the quantum Stark effect as expected due to the nonpolar orientation. Finally, these radial nonpolar quantum wells were used in room-temperature single-wire electroluminescent devices emitting at 392 nm by exploiting sidewall emission.
A Full-Visible-Spectrum Invisibility Cloak for Mesoscopic Metal Wires.
Kim, Sang-Woo; An, Byeong Wan; Cho, Eunjin; Hyun, Byung Gwan; Moon, Yoon-Jong; Kim, Sun-Kyung; Park, Jang-Ung
2018-06-13
Structured metals can sustain a very large scattering cross-section that is induced by localized surface plasmons, which often has an adverse effect on their use as transparent electrodes in displays, touch screens, and smart windows due to an issue of low clarity. Here, we report a broadband optical cloaking strategy for the network of mesoscopic metal wires with submicrometer to micrometer diameters, which is exploited for manufacturing and application of high-clarity metal-wires-based transparent electrodes. We prepare electrospun Ag wires with 300-1800 nm in diameter and perform a facile surface oxidation process to form Ag/Ag 2 O core/shell heterogeneous structures. The absorptive Ag 2 O shell, together with the coating of a dielectric cover, leads to the cancellation of electric multipole moments in Ag wires, thereby drastically suppressing plasmon-mediated scattering over the full visible spectrum and rendering Ag wires to be invisible. Simultaneously with the effect of invisibility, the transmittance of Ag/Ag 2 O wires is significantly improved compared to bare Ag wires, despite the formation of an absorptive Ag 2 O shell. As an application example, we demonstrate that these invisible Ag wires serve as a high-clarity, high-transmittance, and high-speed defroster for automotive windshields.
NASA Technical Reports Server (NTRS)
Williams, Martha; Roberson, Luke; Caraccio, Anne
2010-01-01
This viewgraph presentation describes new technologies in polymer and material chemistry that benefits NASA programs and missions. The topics include: 1) What are Polymers?; 2) History of Polymer Chemistry; 3) Composites/Materials Development at KSC; 4) Why Wiring; 5) Next Generation Wiring Materials; 6) Wire System Materials and Integration; 7) Self-Healing Wire Repair; 8) Smart Wiring Summary; 9) Fire and Polymers; 10) Aerogel Technology; 11) Aerogel Composites; 12) Aerogels for Oil Remediation; 13) KSC's Solution; 14) Chemochromic Hydrogen Sensors; 15) STS-130 and 131 Operations; 16) HyperPigment; 17) Antimicrobial Materials; 18) Conductive Inks Formulations for Multiple Applications; and 19) Testing and Processing Equipment.
Measurement of heat conduction through stacked screens
NASA Technical Reports Server (NTRS)
Lewis, M. A.; Kuriyama, T.; Kuriyama, F.; Radebaugh, R.
1998-01-01
This paper describes the experimental apparatus for the measurement of heat conduction through stacked screens as well as some experimental results taken with the apparatus. Screens are stacked in a fiberglass-epoxy cylinder, which is 24.4 mm in diameter and 55 mm in length. The cold end of the stacked screens is cooled by a Gifford-McMahon (GM) cryocooler at cryogenic temperature, and the hot end is maintained at room temperature. Heat conduction through the screens is determined from the temperature gradient in a calibrated heat flow sensor mounted between the cold end of the stacked screens and the GM cryocooler. The samples used for these experiments consisted of 400-mesh stainless steel screens, 400-mesh phosphor bronze screens, and two different porosities of 325-mesh stainless steel screens. The wire diameter of the 400-mesh stainless steel and phosphor bronze screens was 25.4 micrometers and the 325-mesh stainless steel screen wire diameters were 22.9 micrometers and 27.9 micrometers. Standard porosity values were used for the experimental data with additional porosity values used on selected experiments. The experimental results showed that the helium gas between each screen enhanced the heat conduction through the stacked screens by several orders of magnitude compared to that in vacuum. The conduction degradation factor is the ratio of actual heat conduction to the heat conduction where the regenerator material is assumed to be a solid rod of the same cross sectional area as the metal fraction of the screen. This factor was about 0.1 for the stainless steel and 0.022 for the phosphor bronze, and almost constant for the temperature range of 40 to 80 K at the cold end.
Measurement of heat conduction through stacked screens.
Lewis, M A; Kuriyama, T; Kuriyama, F; Radebaugh, R
1998-01-01
This paper describes the experimental apparatus for the measurement of heat conduction through stacked screens as well as some experimental results taken with the apparatus. Screens are stacked in a fiberglass-epoxy cylinder, which is 24.4 mm in diameter and 55 mm in length. The cold end of the stacked screens is cooled by a Gifford-McMahon (GM) cryocooler at cryogenic temperature, and the hot end is maintained at room temperature. Heat conduction through the screens is determined from the temperature gradient in a calibrated heat flow sensor mounted between the cold end of the stacked screens and the GM cryocooler. The samples used for these experiments consisted of 400-mesh stainless steel screens, 400-mesh phosphor bronze screens, and two different porosities of 325-mesh stainless steel screens. The wire diameter of the 400-mesh stainless steel and phosphor bronze screens was 25.4 micrometers and the 325-mesh stainless steel screen wire diameters were 22.9 micrometers and 27.9 micrometers. Standard porosity values were used for the experimental data with additional porosity values used on selected experiments. The experimental results showed that the helium gas between each screen enhanced the heat conduction through the stacked screens by several orders of magnitude compared to that in vacuum. The conduction degradation factor is the ratio of actual heat conduction to the heat conduction where the regenerator material is assumed to be a solid rod of the same cross sectional area as the metal fraction of the screen. This factor was about 0.1 for the stainless steel and 0.022 for the phosphor bronze, and almost constant for the temperature range of 40 to 80 K at the cold end.
The performance of cable braids and terminations to lightning induced transients
NASA Technical Reports Server (NTRS)
Crofts, David
1991-01-01
The latest specification detailing the test waveforms for indirect lightning transients as applied to aircraft wiring systems specify very high voltages and currents. Although considerable data exists for measuring cable screen leakage using such methods as surface transfer impedance and bulk cable injection, there is little data on the likely core transient level that is likely to be induced from these threats. In particular, the new Waveform 5 at very high current levels (10 kA) is reputed to cause severe cable damage. A range of representative cables were made with various screen termination techniques and screening levels. These were tested first to determine their relative screening performance and then they were subjected to lightning transient testing to all the specified waveforms. Core voltages were measured for each test. Tests were also performed on bundles with fewer wires to determine the failure criteria with Waveform 5 and these tests also include flat conductor cables. The test showed that correctly terminated cable bundles performed well in all the tests and would provide a high level of protection to the electronic systems. The use of overbraides, provided the individual screens are well terminated, appears to be unnecessary.
Thermoelectric device with multiple, nanometer scale, elements
NASA Technical Reports Server (NTRS)
Fleurial, Jean-Pierre (Inventor); Ryan, Margaret A. (Inventor); Borshchevsky, Alexander (Inventor); Herman, Jennifer (Inventor)
2006-01-01
A thermoelectric device formed of nanowires on the nm scale. The nanowires are preferably of a size that causes quantum confinement effects within the wires. The wires are connected together into a bundle to increase the power density.
Shape memory alloy wires turn composites into smart structures: I. Material requirements
NASA Astrophysics Data System (ADS)
Schrooten, Jan; Michaud, Veronique J.; Zheng, Yanjun; Balta-Neumann, J. Antonio; Manson, Jan-Anders E.
2002-07-01
Composites containing thin Shape Memory Alloy (SMA) wires show great potential as materials able to adapt their shape, thermal behavior or vibrational properties to external stimuli. The functional properties of SMA-composites are directly related to the constraining effect of the matrix on the reversible martensitic transformation of the embedded pre-strained SMA wires. The present work reports results of a concerted European effort towards a fundamental understanding of the manufacturing and design of SMA composites. This first part investigates the transformational behavior of constrained SMA wires and its translation into functional properties of SMA composites. Thermodynamic and thermomechanical experiments were performed on SMA wires. A model was developed to simulate the thermomechanical behavior of the wires. From the screening of potential wires it was concluded that NiTiCu, as well as R-phase NiTi appeared as best candidates. Requirements for the host composite materials were surveyed. A Kevlar-epoxy system was chosen. Finally, the quality of the SMA wire-resin interface was assessed by two different techniques. These indicated that a thin oxide layer seems to provide the best interfacial strength. A temperature window in which SMA composites can be safely used was also defined. The manufacturing and properties of the SMA composites will be discussed in Part II.
SIGIR Quarterly Report to the United States Congress
2007-04-30
4975 APOLLO PORTABLE PROJECTOR SCREEN 60” INSTANT CINEMA PROJECTION SCREEN ITEM# 20022351 SYTLES#: 60300 $12,750.00 $12,750.00 $0.00 CEFMS ISFF2 4/2...Generators: 200 MW ( Japanese Generator Sets) Start Date: 9/26/2003 13C 400kV Line from Baghdad South to Diwaniyah (27 towers; 810 km of wire) Start Date
Effectiveness of common fish screen materials to protect lamprey ammocoetes
Rose, Brien P.; Mesa, Matthew G.
2012-01-01
Understanding the effects of irrigation diversions on populations of Pacific lampreyLampetra tridentata in the Columbia River basin is needed for their recovery. We tested the effectiveness of five common fish screen materials for excluding lamprey ammocoetes: interlock (IL), vertical bar (VB), perforated plate (PP), and 12-gauge and 14-gauge wire cloth (WC12) and (WC14). When fish (28–153 mm) were exposed for 60 min to screen panels perpendicular to an approach velocity of 12 cm/s in a recirculating flume, the percentage of ammocoetes entrained (i.e., passed through the screen) was 26% for the IL, 18% for the PP, 33% for the VB, 62% for the WC14, and 65% for the WC12 screens. For all screens, most fish were entrained within the first 15–20 min. Fish length significantly influenced entrainment, with the PP, VB, and IL screens preventing fish greater than 50–65 mm from entrainment and the WC14 and WC12 screens preventing entrainment of fish greater than 90–110 mm. Fish of all sizes repeatedly became impinged (i.e., contacting the screen for more than 1 s) on the screens, with the frequency of impingement events increasing during the first 5 min and becoming relatively stable thereafter. Impingement ranges were highest on the IL screen (36–62%), lowest on the WC14 and WC12 screens (13–31%), and intermediate on the PP and VB screens (23–54%). However, the WC14 and WC12 screens had fewer and larger fish remaining as time elapsed because so many were entrained. For all screen types, injuries were rare and minor, and no fish died after overnight posttest holding. Our results indicate that wire cloth screens should be replaced, where practical, with perforated plate, vertical bar, or interlocking bar screens to reduce lamprey entrainment at water diversions.
NASA Astrophysics Data System (ADS)
Texier, Christophe; Mitscherling, Johannes
2018-02-01
We study the nonlinear conductance G ˜∂2I /∂ V2|V =0 in coherent quasi-one-dimensional weakly disordered metallic wires. Our analysis is based on the scattering approach and includes the effect of Coulomb interaction. The nonlinear conductance correlations can be related to integrals of two fundamental correlation functions: the correlator of functional derivatives of the conductance and the correlator of injectivities (the injectivity is the contribution to the local density of states of eigenstates incoming from one contact). These correlators are obtained explicitly by using diagrammatic techniques for weakly disordered metals. In a coherent wire of length L , we obtain rms (G )≃0.006 ETh-1 (and
NASA Astrophysics Data System (ADS)
Burke, G. J.; King, R. J.; Miller, E. K.
1984-09-01
Relative communication efficiency (RCE) as defined by Fenwick and Weeks compares the field of a test antenna to that of a reference antenna at the same location for equal input plower to each antenna. Thus, RCE is similar to power gain but is definable in the presence of ground. The effectiveness of antennas in launching TM surface waves was compared. Antennas considered included the vertical dipole, monople on a ground stake, monopole on a radial-wire ground screen, Beverage antenna and vertical half rhombic. Since the performance of these antennas is strongly dependent on parameters such as the number wires in a ground screen or the length of a Beverage antenna, results are presented with parameters varying over a reasonable range. Thus, antenna performance can be weighed against the effort and limitations of construction.
Goffin, N J; Higginson, R L; Tyrer, J R
2016-12-01
In laser cladding, the potential benefits of wire feeding are considerable. Typical problems with the use of powder, such as gas entrapment, sub-100% material density and low deposition rate are all avoided with the use of wire. However, the use of a powder-based source material is the industry standard, with wire-based deposition generally regarded as an academic curiosity. This is because, although wire-based methods have been shown to be capable of superior quality results, the wire-based process is more difficult to control. In this work, the potential for wire shaping techniques, combined with existing holographic optical element knowledge, is investigated in order to further improve the processing characteristics. Experiments with pre-placed wire showed the ability of shaped wire to provide uniformity of wire melting compared with standard round wire, giving reduced power density requirements and superior control of clad track dilution. When feeding with flat wire, the resulting clad tracks showed a greater level of quality consistency and became less sensitive to alterations in processing conditions. In addition, a 22% increase in deposition rate was achieved. Stacking of multiple layers demonstrated the ability to create fully dense, three-dimensional structures, with directional metallurgical grain growth and uniform chemical structure.
Higginson, R. L.; Tyrer, J. R.
2016-01-01
In laser cladding, the potential benefits of wire feeding are considerable. Typical problems with the use of powder, such as gas entrapment, sub-100% material density and low deposition rate are all avoided with the use of wire. However, the use of a powder-based source material is the industry standard, with wire-based deposition generally regarded as an academic curiosity. This is because, although wire-based methods have been shown to be capable of superior quality results, the wire-based process is more difficult to control. In this work, the potential for wire shaping techniques, combined with existing holographic optical element knowledge, is investigated in order to further improve the processing characteristics. Experiments with pre-placed wire showed the ability of shaped wire to provide uniformity of wire melting compared with standard round wire, giving reduced power density requirements and superior control of clad track dilution. When feeding with flat wire, the resulting clad tracks showed a greater level of quality consistency and became less sensitive to alterations in processing conditions. In addition, a 22% increase in deposition rate was achieved. Stacking of multiple layers demonstrated the ability to create fully dense, three-dimensional structures, with directional metallurgical grain growth and uniform chemical structure. PMID:28119550
Emerging Technologies in Aircraft Crashworthiness
1999-05-01
is both lightweight and accommodates the expanding occupant range. Solutions such as EA’s with variable-thickness wire-benders, multiple-stage wire ... bending mechanisms, and energy-absorbing foams have been developed. Another focus will be on restraint-system integration that is designed for a
NASA Astrophysics Data System (ADS)
Darr, Samuel Ryan
Technologies that enable the storage and transfer of cryogenic propellants in space will be needed for the next generation vehicles that will carry humans to Mars. One of the candidate technologies is the screen channel liquid acquisition device (LAD), which uses a metal woven wire mesh to separate the liquid and vapor phases so that single-phase liquid propellant can be transferred in microgravity. The purpose of this work is to provide an accurate hydrodynamic model of the liquid flow through a screen channel LAD. Chapter 2 provides a derivation of the flow-through-screen (FTS) boundary condition. The final boundary condition more accurately represents the complex geometry of metal woven wire mesh than the current model used in the literature. The effect of thermal contraction on the screen geometry due to large temperature changes common in cryogenic systems is quantified in this chapter as well. Chapter 3 provides a two-dimensional (2-D) analytical solution of the velocity and pressure fields in a screen channel LAD. This solution, which accounts for non-uniform injection through the screen, is compared with the traditional 1-D model which assumes a constant, uniform injection velocity. Chapter 4 describes the setup and results of an experiment that measures both the velocity and pressure fields in a screen channel LAD in order to validate the 2-D model. Results show that the 2-D model performs best against the new data and historical data. With the improved FTS boundary condition and the 2-D model, the pressure drop of a screen channel LAD is described with excellent accuracy. The result of this work is a predictive tool that will instill confidence in the design of screen channel LADs for future in-space propulsion systems.
Steering of quantum waves: Demonstration of Y-junction transistors using InAs quantum wires
NASA Astrophysics Data System (ADS)
Jones, Gregory M.; Qin, Jie; Yang, Chia-Hung; Yang, Ming-Jey
2005-06-01
In this paper we demonstrate using an InAs quantum wire Y-branch switch that the electron wave can be switched to exit from the two drains by a lateral gate bias. The gating modifies the electron wave functions as well as their interference pattern, causing the anti-correlated, oscillatory transconductances. Our result suggests a new transistor function in a multiple-lead ballistic quantum wire system.
Research study on stellar X-ray imaging experiment, volume 1
NASA Technical Reports Server (NTRS)
Wilson, H. H.; Vanspeybroeck, L. P.
1972-01-01
The use of microchannel plates as focal plane readout devices and the evaluation of mirrors for X-ray telescopes applied to stellar X-ray imaging is discussed. The microchannel plate outputs were either imaged on a phosphor screen which was viewed by a low light level vidicon or on a wire array which was read out by digitally processing the output of a charge division network attached to the wires. A service life test which was conducted on two image intensifiers is described.
NASA Technical Reports Server (NTRS)
Carpenter, K. H.
1974-01-01
The design, construction, and test history of a 4096 word by 18 bit random access NDRO Plated Wire Memory for use in conjunction with a spacecraft input/output and central processing unit is reported. A technical and functional description is given along with diagrams illustrating layout and systems operation. Test data is shown on the procedures and results of system level and memory stack testing, and hybrid circuit screening. A comparison of the most significant physical and performance characteristics of the memory unit versus the specified requirements is also included.
An Experimental Study of the Dynamics of an Unsteady Turbulent Boundary Layer.
1982-12-01
honeycomb combination into the screen box. The screen box is made of plexiglas, and the screens are made of stainless steel wire (24 gauge, 70% porosity...port plug was modified to accommodate at its cen- ter a stainless steel stem with a disk on the end toward the inside of the tunnel. The stem is spring...necessay and Identify by block nomber) * turbulent boundary layers fluid dynamics free stream velocity A B r R CT si royy.rs ebb it ,imseesa nd ideiiit
Training Objectives for Tank Platoon Leaders Covering Tasks Performed during Four Armor Operations
1983-01-01
screens to conceal their movement to covered and concealed positions. The M250 grenade launcher consists of two six-barreled dischargers wired for two...generates smoke by the injestion of fuel onto the hot engine exhaust system. The smoke screen generated by VEESS is used to compli- ment the M250 smoke...grenade system by reinforcing and sustaining the screen created by the M250 system. The purpose of the smoke producing systems is to make it more
Wireless power transfer magnetic couplers
Wu, Hunter; Gilchrist, Aaron; Sealy, Kylee
2016-01-19
A magnetic coupler is disclosed for wireless power transfer systems. A ferrimagnetic component is capable of guiding a magnetic field. A wire coil is wrapped around at least a portion of the ferrimagnetic component. A screen is capable of blocking leakage magnetic fields. The screen may be positioned to cover at least one side of the ferrimagnetic component and the coil. A distance across the screen may be at least six times an air gap distance between the ferrimagnetic component and a receiving magnetic coupler.
Piezo-Potential Generation in Capacitive Flexible Sensors Based on GaN Horizontal Wires.
El Kacimi, Amine; Pauliac-Vaujour, Emmanuelle; Delléa, Olivier; Eymery, Joël
2018-06-12
We report an example of the realization of a flexible capacitive piezoelectric sensor based on the assembly of horizontal c¯-polar long Gallium nitride (GaN) wires grown by metal organic vapour phase epitaxy (MOVPE) with the Boostream ® technique spreading wires on a moving liquid before their transfer on large areas. The measured signal (<0.6 V) obtained by a punctual compression/release of the device shows a large variability attributed to the dimensions of the wires and their in-plane orientations. The cause of this variability and the general operating mechanisms of this flexible capacitive device are explained by finite element modelling simulations. This method allows considering the full device composed of a metal/dielectric/wires/dielectric/metal stacking. We first clarify the mechanisms involved in the piezo-potential generation by mapping the charge and piezo-potential in a single wire and studying the time-dependent evolution of this phenomenon. GaN wires have equivalent dipoles that generate a tension between metallic electrodes only when they have a non-zero in-plane projection. This is obtained in practice by the conical shape occurring spontaneously during the MOVPE growth. The optimal aspect ratio in terms of length and conicity (for the usual MOVPE wire diameter) is determined for a bending mechanical loading. It is suggested to use 60⁻120 µm long wires (i.e., growth time less than 1 h). To study further the role of these dipoles, we consider model systems with in-plane 1D and 2D regular arrays of horizontal wires. It is shown that a strong electrostatic coupling and screening occur between neighbouring horizontal wires depending on polarity and shape. This effect, highlighted here only from calculations, should be taken into account to improve device performance.
2013-01-01
GaN wires are grown on a Si (111) substrate by metal organic vapour-phase epitaxy on a thin deposited AlN blanket and through a thin SiNx layer formed spontaneously at the AlN/Si interface. N-doped wires are used as templates for the growth of core-shell InGaN/GaN multiple quantum wells coated by a p-doped shell. Standing single-wire heterostructures are connected using a metallic tip and a Si substrate backside contact, and the electroluminescence at room temperature and forward bias is demonstrated at 420 nm. This result points out the feasibility of lower cost nitride-based wires for light-emitting diode applications. PMID:23391377
Power and energy of exploding wires
Valancius, Cole J.; Garasi, Christopher J.; O?Malley, Patrick D.
2017-01-01
Exploding wires are used in many high-energy applications, such as initiating explosives. Previous work analyzing gold wire burst in detonator applications has shown burst current and action metrics to be inconsistent with burst phenomenon across multiple firing-sets. Energy density better captures the correlation between different wire geometries, different electrical inputs, and explosive initiation. This idea has been expanded upon, to analyze the burst properties in power-energy space. Further inconsistencies in the understanding of wire burst and its relation to peak voltage have been found. An argument will be made for redefining the definition of burst. The result is a moremore » broad understanding of rapid metal phase transition and the initiation of explosives in EBW applications.« less
Power and energy of exploding wires
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valancius, Cole J.; Garasi, Christopher J.; O?Malley, Patrick D.
Exploding wires are used in many high-energy applications, such as initiating explosives. Previous work analyzing gold wire burst in detonator applications has shown burst current and action metrics to be inconsistent with burst phenomenon across multiple firing-sets. Energy density better captures the correlation between different wire geometries, different electrical inputs, and explosive initiation. This idea has been expanded upon, to analyze the burst properties in power-energy space. Further inconsistencies in the understanding of wire burst and its relation to peak voltage have been found. An argument will be made for redefining the definition of burst. The result is a moremore » broad understanding of rapid metal phase transition and the initiation of explosives in EBW applications.« less
Mouse Visual Neocortex Supports Multiple Stereotyped Patterns of Microcircuit Activity
Sadovsky, Alexander J.
2014-01-01
Spiking correlations between neocortical neurons provide insight into the underlying synaptic connectivity that defines cortical microcircuitry. Here, using two-photon calcium fluorescence imaging, we observed the simultaneous dynamics of hundreds of neurons in slices of mouse primary visual cortex (V1). Consistent with a balance of excitation and inhibition, V1 dynamics were characterized by a linear scaling between firing rate and circuit size. Using lagged firing correlations between neurons, we generated functional wiring diagrams to evaluate the topological features of V1 microcircuitry. We found that circuit connectivity exhibited both cyclic graph motifs, indicating recurrent wiring, and acyclic graph motifs, indicating feedforward wiring. After overlaying the functional wiring diagrams onto the imaged field of view, we found properties consistent with Rentian scaling: wiring diagrams were topologically efficient because they minimized wiring with a modular architecture. Within single imaged fields of view, V1 contained multiple discrete circuits that were overlapping and highly interdigitated but were still distinct from one another. The majority of neurons that were shared between circuits displayed peri-event spiking activity whose timing was specific to the active circuit, whereas spike times for a smaller percentage of neurons were invariant to circuit identity. These data provide evidence that V1 microcircuitry exhibits balanced dynamics, is efficiently arranged in anatomical space, and is capable of supporting a diversity of multineuron spike firing patterns from overlapping sets of neurons. PMID:24899701
Design, fabrication, and testing of a low frequency MEMS piezoelectromagnetic energy harvester
NASA Astrophysics Data System (ADS)
Fernandes, Egon; Martin, Blake; Rua, Isabel; Zarabi, Sid; Debéda, Hélène; Nairn, David; Wei, Lan; Salehian, Armaghan
2018-03-01
This paper details a power solution for smart grid applications to replace batteries by harvesting the electromagnetic energy from a current-carrying wire. A MEMS piezoelectromagnetic energy harvester has been fabricated using PZT screen-printing technology with a centrally-supported meandering geometry. The energy harvesting device employs a symmetric geometry to increase its power output by reducing the effects of the torsional modes and the resultant overall strain nodes in the system subsequently reduce the complexities for the electrode fabrication. The unit is modelled using COMSOL to determine mode shapes and frequency response functions. A 12.7 mm by 14.7 mm unit is fabricated by screen-printing 75 μm-thick PZT on a stainless steel substrate and then experimentally tested to validate the FEA results. Experimentally, the harvester is shown to produce 9 μW from a wire carrying 7 A while operating at a distance of 6.5 mm from the wire. The design of the current work results in a greater normalized power density than other MEMS based piezoelectromagnetic devices and shows great potential relative to larger devices that use bulk or thin film piezoelectrics.
West, A E; Jones, M L; Newcombe, R G
1995-11-01
Two arch wires commonly used for initial tooth alignment were compared with regard to their clinical effectiveness. The two arch wires tested were 0.0155-inch diameter multiple-stranded stainless steel wire (Dentaflex, Dentaurium, Optident, Yorkshire, England) and 0.014-inch diameter nickel-titanium alloy wire (NiTi, ORMCO Co., Monrovia, Calif.). Consecutive patients attending an orthodontic clinic for routine placement of a fixed appliance were randomly assigned one of these two initial arch wires. Good quality alginate impressions of the appropriate dental arch were taken before arch wire placement and also at the subsequent appointment, which was, on average, 6 weeks later. Seventy-four arches were used in this study. The degree of tooth alignment achieved for each wire type was compared with a Reflex Microscope (Reflex Measurement Ltd., Butleigh, England) to make detailed measurements on the resultant casts. The degree of initial alignment achieved with the two wires was similar over this 6-week period. However, some differences were found for the lower labial segment where the interbracket span is usually reduced and where the superelastic nickel-titanium wire was found to give improved alignment. No threshold of crowding was found where one arch wire performed better than the other.
Use of Multiple Operatories in Dental Care Delivery.
1982-02-01
07212 Repair Traumatic Wounds, Complex Under 5cm 2.6 07213 Repair Traumatic Wounds, Complex Over 5cm 5.3 07260 Cleft Palate Repair 10.6 07265 Cleft Lip ...Facial Prosthesis 18.5 05940 Implants 16.8 05950 Maxillary Inclined Plane or Occlusal Table 19.4 05955 Mandibular Guide Flange 16.8 05960 Palatal Lift...Passive Lingual or Palatal Wire 1.2 08446 Face Bow, J Hooks, Clinical Cup 1.2 08447 Active Lingual or Palatal Wire 1.2 08448 Multi-Stranded Wire 0.6 08510
Parallel flow diffusion battery
Yeh, H.C.; Cheng, Y.S.
1984-01-01
A parallel flow diffusion battery for determining the mass distribution of an aerosol has a plurality of diffusion cells mounted in parallel to an aerosol stream, each diffusion cell including a stack of mesh wire screens of different density.
Parallel flow diffusion battery
Yeh, Hsu-Chi; Cheng, Yung-Sung
1984-08-07
A parallel flow diffusion battery for determining the mass distribution of an aerosol has a plurality of diffusion cells mounted in parallel to an aerosol stream, each diffusion cell including a stack of mesh wire screens of different density.
Use of reinforced inorganic cement materials for spark wire and drift chamber wire frames
NASA Technical Reports Server (NTRS)
1987-01-01
The results of a survey, materials test, and analysis study directed toward the development of an inorganic glass-fiber reinforced cement material for use in the construction of space qualified spark wire frames and drift chamber frames are presented. The purpose for this research was to evaluate the feasibility of using glass fiber reinforced cement (GFRC) for large dimensioned structural frames for supporting a number of precisely located spark wires in multiple planes. A survey of the current state of the art in fiber reinforced cement materials was made; material sample mixes were made and tested to determine their laboratory performances. Tests conducted on sample materials showed that compressive and flexural strengths of this material could approach values which would enable fabrication of structural spark wire frames.
Lunar Module Wiring Design Considerations and Failure Modes
NASA Technical Reports Server (NTRS)
Interbartolo, Michael
2009-01-01
This slide presentation reviews the considerations for the design of wiring for the Lunar Module. Included are a review of the choice of conductors and insulations, the wire splicing (i.e., crimping, and soldering), the wire connectors, and the fabrication of the wire harnesses. The problems in fabrication include the wires being the wrong length, the damage due to the sharp edges, the requried use of temproary protective covers and inadequate training. The problems in the wire harness installation include damge from sharp eges, work on adjacent harnesses, connector damage, and breaking wires. Engineering suggestions from the Apollo-era in reference to the conductors that are reviewed include: the use of plated conductors, and the use of alloys for stronger wiring. In refernce to insulation, the suggestions from Apollo era include the use of polymer tape-wrap wire insulation due to the light weight, however, other types of modern insulation might be more cost-effective. In reference to wire splices and terminal boards the suggestions from the Apollo Era include the use of crimp splices as superior to solder splices, joining multiple wire to a common point using modular plug-ins might be more reliable, but are heavier than crimp splicing. For connectors, the lessons from the Apollo era indicate that a rear environmental seal that does not require additional potting is preferred, and pins should be crimped or welded to the incoming wires and be removable from the rear of the connector.
Lam, Carl W; Lim, Seong-Rin; Schoenung, Julie M
2011-05-15
Modern manufacturing of printed wiring boards (PWBs) involves extensive use of various hazardous chemicals in different manufacturing steps such as board preparation, circuit design transfer, etching and plating processes. Two complementary environmental screening methods developed by the U.S. EPA, namely: (i) the Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts (TRACI) and (ii) Risk-Screening Environmental Indicators (RSEI), are used to quantify geographic and chemical environmental impacts in the U.S. PWB manufacturing industry based on Toxics Release Inventory (TRI) data. Although the release weight percentages of industrial chemicals such as methanol, glycol ethers and dimethylformamide comprise the larger fraction of reported air and water emissions, results indicate that lead, copper and their compounds' releases correspond to the highest environmental impact from toxicity potentials and risk-screening scores. Combining these results with further knowledge of PWB manufacturing, select alternative chemical processes and materials for pollution prevention are discussed. Examples of effective pollution prevention options in the PWB industry include spent etchant recovery technologies, and process and material substitutions. In addition, geographic assessment of environmental burden highlights states where promotion of pollution prevention strategies and emissions regulations can have the greatest effect to curb the PWB industry's toxic release impacts. Copyright © 2011 Elsevier B.V. All rights reserved.
Handbook of estimating data, factors, and procedures. [for manufacturing cost studies
NASA Technical Reports Server (NTRS)
Freeman, L. M.
1977-01-01
Elements to be considered in estimating production costs are discussed in this manual. Guidelines, objectives, and methods for analyzing requirements and work structure are given. Time standards for specific specfic operations are listed for machining, sheet metal working, electroplating and metal treating; painting; silk screening, etching and encapsulating; coil winding; wire preparation and wiring; soldering; and the fabrication of etched circuits and terminal boards. The relation of the various elements of cost to the total cost as proposed for various programs by various contractors is compared with government estimates.
Constrained sheath optics for high thrust density, low specific impulse ion thrusters
NASA Technical Reports Server (NTRS)
Wilbur, Paul J.; Han, Jian-Zhang
1987-01-01
The results of an experimental study showing that a contoured, fine wire mesh attached to the screen grid can be used to control the divergence characteristics of ion beamlets produced at low net-to-total accelerating voltage ratios are presented. The influence of free and constrained-sheath optics systems on beamlet divergence characteristics are found to be similar in the operating regime investigated, but it was found that constrained-sheath optics systems can be operated at higher perveance levels than free-sheath ones. The concept of a fine wire interference probe that can be used to study ion beamlet focusing behavior is introduced. This probe is used to demonstrate beamlet focusing to a diameter about one hundreth of the screen grid extraction aperture diameter. Additional testing is suggested to define an optimally contoured mesh that could yield well focused beamlets at net-to-total accelerating voltage ratios below about 0.1.
NASA Astrophysics Data System (ADS)
Olles, Joseph; Garasi, Christopher; Ball, J. Patrick
2017-11-01
Electrically-pulsed wires undergo multiple phase changes including a postulated metastable phase resulting in explosive wire growth. Simulations using the MHD approximation attempt to account for the governing physics, but lack the material properties (equations-of-state and electrical conductivity) to accurately predict the phase evolution of the exploding (bursting) wire. To explore the dynamics of an exploding copper wire (in water), we employ a digital micro-Schlieren streak photography technique. This imaging quantifies wire expansion and shock waves emitted from the wire during phase changes. Using differential voltage probes, a Rogowski coil, and timing fiducials, the phase change of the wire is aligned with electrical power and energy deposition. Time-correlated electrical diagnostics and imaging allow for detailed validation of MHD simulations, comparing observed phases with phase change details found in the material property descriptions. In addition to streak imaging, a long exposure image is taken to capture axial striations along the length of the wire. These images are used to compare with results from 3D MHD simulations which propose that these perturbations impact the rate of wire expansion and temporal change in phases. If successful, the experimental data will identify areas for improvement in the material property models, and modeling results will provide insight into the details of phase change in the wire with correlation to variations in the electrical signals.
Multiple-stripe lithiation mechanism of individual SnO2 nanowires in a flooding geometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhong, Li; Liu, Xiao H.; Wang, G. F.
2011-06-17
The atomic scale lithiation mechanism of individual SnO2 nanowires in a flooding geometry with the entire wires being immersed in the electrolyte was revealed by in-situ transmission electron microscopy. The lithiation initiated multiple stripes with width of a few nanometer parallel to {020} planes transversing the entire wires, serving as multiple reaction fronts for late stage of lithiation. Inside the stripes, we identified high density of dislocations and enlarged inter-planar spacing, which provide effective path for lithium ion transport. The density of the stripes increased with further lithiation, and eventually they merged with one another, causing a large enlongation andmore » volume expansion and the crystalline to amorphous phase transformation. This multiple stripes and multiple reaction fronts lithiation mechanism is unexpected and differs completely from the expected core-shell lithiation mechanism.« less
Code of Federal Regulations, 2013 CFR
2013-10-01
... CABLE TELEVISION SERVICE Cable Inside Wiring § 76.800 Definitions. (a) MDU. A multiple dwelling unit... owns or controls the common areas of a multiple dwelling unit building. (c) MVPD. A multichannel video...
Code of Federal Regulations, 2014 CFR
2014-10-01
... CABLE TELEVISION SERVICE Cable Inside Wiring § 76.800 Definitions. (a) MDU. A multiple dwelling unit... owns or controls the common areas of a multiple dwelling unit building. (c) MVPD. A multichannel video...
Code of Federal Regulations, 2012 CFR
2012-10-01
... CABLE TELEVISION SERVICE Cable Inside Wiring § 76.800 Definitions. (a) MDU. A multiple dwelling unit... owns or controls the common areas of a multiple dwelling unit building. (c) MVPD. A multichannel video...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, Scott M., E-mail: Thompson.scott@mayo.edu; Gorny, Krzysztof R.; Jondal, Danielle E.
A 17-year-old previously healthy female presented with a progressive soft tissue infiltrative process involving the neck and thorax. Extensive diagnostic evaluation including multiple imaging, laboratory, and biopsy studies was nondiagnostic. Due to an urgent need to establish a diagnosis and several previous nondiagnostic biopsies, she was referred to interventional radiology for MRI-guided wire localization immediately prior to open surgical biopsy. Under general anesthesia, wires were placed in the areas of increased T2 signal within the bilateral splenius capitis muscles using intermittent MRI-guidance followed by immediate surgical biopsy down to the wires. Pathology confirmed the diagnosis of diffuse large B-cell lymphoma.
Removal of Long-Lived Radon Daughters by Electropolishing Thin Layers of Stainless Steel
NASA Astrophysics Data System (ADS)
White, James; Schnee, Richard; Bunker, Raymond; Bowles, Michael; Cushman, Priscilla; Epland, Matthew; Pepin, Mark; Guiseppe, Vince
2012-10-01
Long-lived alpha and beta emitters in the Radon decay chain on detector surfaces may be limiting background in many experiments attempting to detect dark matter or neutrinoless double beta decay. To screen detector surfaces for this radioactive contamination, a low-radiation, multi-wire proportional chamber (the BetaCage) is under construction. Removal of Pb-210 implanted on its 25-micron stainless steel wires without causing significant variation in the diameter of the wires is critical to the BetaCage's ultimate sensitivity. An apparatus to perform electropolishing trials to remove roughly a micron of material has been assembled. These trials have shown promising results. Stainless steel square samples implanted with Pb-210 have shown counts with a reduction factor greater than 10 after electropolishing according to gamma assay. Furthermore, alpha counting has produced similar results, with a reduction factor greater than 100. Lastly, the diameters of wires after electropolishing have remained sufficiently uniform, with reduction in thickness consistent with expectations.
Astrophysically relevant radiatively cooled hypersonic bow shocks in nested wire arrays
NASA Astrophysics Data System (ADS)
Ampleford, David
2009-11-01
We have performed laboratory experiments which introduce obstructions into hypersonic plasma flows to study the formation of shocks. Astrophysical observations have demonstrated many examples of equivalent radiatively cooled bow shocks, for example the head of protostellar jets or supernova remnants passing through the interstellar medium or between discrete clumps in jets. Wire array z-pinches allow us to study quasi-planar radiatively cooled flows in the laboratory. The early stage of a wire array z-pinch implosion consists of a steady flow of the wire material towards the axis. Given a high rate of radiative cooling, these flows reach high sonic- Mach numbers, typically up to 5. The 2D nature of this configuration allows the insertion of obstacles into the flow, such as a concentric ``inner'' wire array, as has previously been studied for ICF research. Here we study the application of such a nested array to laboratory astrophysics where the inner wires act as obstructions perpendicular to the flow, and induce bow shocks. By varying the wire array material (W/Al), the significance of radiative cooling on these shocks can be controlled, and is shown to change the shock opening angle. As multiple obstructions are present, the experiments show the interaction of multiple bow shocks. It is also possible to introduce a magnetic field around the static object, increasing the opening angle of the shocks. Further experiments can be designed to control the flow density, magnetic field structure and obstruction locations. In collaboration with: S.V. Lebedev, M.E. Cuneo, C.A. Jennings, S.N. Bland, J.P. Chittenden, A. Ciardi, G.N. Hall, S.C. Bott, M. Sherlock, A. Frank, E. Blackman
Guo, Hangwen; Noh, Joo H; Dong, Shuai; Rack, Philip D; Gai, Zheng; Xu, Xiaoshan; Dagotto, Elbio; Shen, Jian; Ward, T Zac
2013-08-14
Electronically phase separated manganite wires are found to exhibit controllable metal-insulator transitions under local electric fields. The switching characteristics are shown to be fully reversible, polarity independent, and highly resistant to thermal breakdown caused by repeated cycling. It is further demonstrated that multiple discrete resistive states can be accessed in a single wire. The results conform to a phenomenological model in which the inherent nanoscale insulating and metallic domains are rearranged through electrophoretic-like processes to open and close percolation channels.
Development of practical high temperature superconducting wire for electric power application
NASA Technical Reports Server (NTRS)
Hawsey, Robert A.; Sokolowski, Robert S.; Haldar, Pradeep; Motowidlo, Leszek R.
1995-01-01
The technology of high temperature superconductivity has gone from beyond mere scientific curiousity into the manufacturing environment. Single lengths of multifilamentary wire are now produced that are over 200 meters long and that carry over 13 amperes at 77 K. Short-sample critical current densities approach 5 x 104 A/sq cm at 77 K. Conductor requirements such as high critical current density in a magnetic field, strain-tolerant sheathing materials, and other engineering properties are addressed. A new process for fabricating round BSCCO-2212 wire has produced wires with critical current densities as high as 165,000 A/sq cm at 4.2 K and 53,000 A/sq cm at 40 K. This process eliminates the costly, multiple pressing and rolling steps that are commonly used to develop texture in the wires. New multifilamentary wires with strengthened sheathing materials have shown improved yield strengths up to a factor of five better than those made with pure silver. Many electric power devices require the wire to be formed into coils for production of strong magnetic fields. Requirements for coils and magnets for electric power applications are described.
High-performance, stretchable, wire-shaped supercapacitors.
Chen, Tao; Hao, Rui; Peng, Huisheng; Dai, Liming
2015-01-07
A general approach toward extremely stretchable and highly conductive electrodes was developed. The method involves wrapping a continuous carbon nanotube (CNT) thin film around pre-stretched elastic wires, from which high-performance, stretchable wire-shaped supercapacitors were fabricated. The supercapacitors were made by twisting two such CNT-wrapped elastic wires, pre-coated with poly(vinyl alcohol)/H3PO4 hydrogel, as the electrolyte and separator. The resultant wire-shaped supercapacitors exhibited an extremely high elasticity of up to 350% strain with a high device capacitance up to 30.7 F g(-1), which is two times that of the state-of-the-art stretchable supercapacitor under only 100% strain. The wire-shaped structure facilitated the integration of multiple supercapacitors into a single wire device to meet specific energy and power needs for various potential applications. These supercapacitors can be repeatedly stretched from 0 to 200% strain for hundreds of cycles with no change in performance, thus outperforming all the reported state-of-the-art stretchable electronics. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
RF verification tasks underway at the Harris Corporation for multiple aperture reflector system
NASA Technical Reports Server (NTRS)
Gutwein, T. A.
1982-01-01
Mesh effects on gain and patterns and adjacent aperture coupling effects for "pie" and circular apertures are discussed. Wire effects for Harris model with Langley scale model results included for assessing D/lamda effects, and wire effects with adjacent aperture coupling were determined. Reflector surface distortion effects (pillows and manufacturing roughness) were studied.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-01
... times for those actions. This AD was prompted by reports of cracking in the frame, or in the frame and frame reinforcement, common to the 1.04- inch nominal diameter wire penetration hole intended for wire routing; and recent reports of multiple adjacent frame cracking found before the compliance time required...
Mechanical properties and aesthetics of FRP orthodontic wire fabricated by hot drawing.
Imai, T; Watari, F; Yamagata, S; Kobayashi, M; Nagayama, K; Toyoizumi, Y; Nakamura, S
1998-12-01
The FRP wires 0.5 mm in diameter with a multiple fiber structure were fabricated by drawing the fiber polymer complex at 250 degrees C for an esthetic, transparent orthodontic wire. Biocompatible CaO-P2O5-SiO2-Al2O3 (CPSA) glass fibers of 8-20 microm in diameter were oriented unidirectionally in the longitudinal direction in PMMA matrix. The mechanical properties were investigated by 3-point flexural test. The FRP wire showed sufficient strength and a very good elastic recovery after deformation. Young's modulus and the flexural load at deflection 1 mm were nearly independent of the fiber diameter and linearly increased with the fiber fraction. The dependence on fiber fraction obeys well the rule of mixture. This FRP wire could cover the range of strength corresponding to the conventional metal orthodontic wires from Ni-Ti used in the initial stage of orthodontic treatments to Co-Cr used in the final stage by changing the volume ratio of glass fibers with the same external diameter. The estheticity in external appearance was excellent. Thus the new FRP wire can satisfy both mechanical properties necessary for an orthodontic wire and enough estheticity, which was not possible for the conventional metal wire.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carpenter, Gary D.; El-Essawy, Wael; Ferreira, Alexandre Peixoto
2016-04-26
A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing formed from two portions that mechanically close around the wire and that contain the current and voltage sensors. The current sensor is a ferrite cylinder formed from at least three portions that form the cylindermore » when the sensor is closed around the wire with a hall effect sensor disposed in a gap between two of the ferrite portions along the circumference to measure current. A capacitive plate or wire is disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.« less
Bubble Point Measurements with Liquid Methane of a Screen Capillary Liquid Acquisition Device
NASA Technical Reports Server (NTRS)
Jurns, John M.; McQuillen, John B.
2009-01-01
Liquid acquisition devices (LADs) can be utilized within a propellant tank in space to deliver single-phase liquid to the engine in low gravity. One type of liquid acquisition device is a screened gallery whereby a fine mesh screen acts as a bubble filter and prevents the gas bubbles from passing through until a crucial pressure differential condition across the screen, called the bubble point, is reached. This paper presents data for LAD bubble point data in liquid methane (LCH4) for stainless steel Dutch twill screens with mesh sizes of 325 by 2300 and 200 by 1400 wires per inch. Data is presented for both saturated and sub-cooled LCH4, and is compared with predicted values.
Code of Federal Regulations, 2012 CFR
2012-10-01
... that: (a) Discharges vertically upward; (b) Has a rain cap or other means of preventing the entrance of rain or snow; (c) Has a screen with 25mm (1 inch) wire mesh or bars not more than 25mm (1 in.) apart on...
Code of Federal Regulations, 2014 CFR
2014-10-01
... that: (a) Discharges vertically upward; (b) Has a rain cap or other means of preventing the entrance of rain or snow; (c) Has a screen with 25mm (1 inch) wire mesh or bars not more than 25mm (1 in.) apart on...
Passive Control of Vortex Shedding via Screen Shroud
NASA Astrophysics Data System (ADS)
Azmi, A. M.; Zhou, T.
2017-12-01
The turbulent wake of screen-shrouded cylinders were experimentally investigated using flow visualization. Screen cylinders made from screen mesh of various porosity (37%, 49%, 61% and 67%) were used as the shrouds. The main purpose of the study is to examine the effect of screen porosity, β and screen diameter ratio, dw /D (wire diameter to cylinder diameter ratio) on the vortex development behind the shrouded cylinders, particularly in supressing the vortex shedding from a circular cylinder. The diameter ratio between the screen shroud and the plain cylinder, D/d was 2.0. The flow Reynolds number based on the shroud diameter, ReD was about 1000. Results showed that the inclusion of the screen shrouds has significant impact on the wake of the circular cylinder. With larger value of the non-dimensional parameter βdw /D, vortex was impaired and the formation length was longer in the shrouded cylinder wake. The vortex generation mechanism was also discussed.
Sié, Essoh J.B.; Kacou, Aka D.; Traoré, A.; Mobiot, C.; Bamba, I.; Lambin, Y.
2014-01-01
Objective To evaluate the results of multiple closed intramedullary Kirschner wiring via a supracondylar entry point for humeral shaft fractures. Patients and methods The charts of 37 patients with humeral shaft fractures treated with the Hackethal's technique between January 2007 and December 2011 were reviewed retrospectively. The operation was performed with the patient lying in supine (n = 22) or lateral (n = 15) position. The elbow was flexed over an articulated support with the arm kept in a vertical position. Thirty-three patients were available for final evaluation with a mean follow-up delay of 14 (range, 6–24) months. We were concerned about fracture union, range of motion of the shoulder and the elbow, and complications. Final evaluation used the criteria by Qidwai. Results Bone union rate was 94%. Restriction of ranges of motion of the shoulder more than 20° was noticed in two patients due to protruding wires. Three patients developed limitation of elbow extension owing to backing out of the wires. The overall results were excellent (n = 26; 79%), good (n = 4; 12%), and poor (n = 3; 9%). Conclusion Closed Hackethal's technique using K-wires gives satisfactory results in terms of bone union and elbow and shoulder function in selected humeral shaft fractures. The articulated support precludes the transolecranon traction. PMID:25983469
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun Zhonghua, E-mail: z.sun@curtin.edu.a; Chaichana, Thanapong
The purpose of the study was to investigate the hemodynamic effect of stent struts (wires) on renal arteries in patients with abdominal aortic aneurysms (AAAs) treated with suprarenal stent-grafts. Two sample patients with AAA undergoing multislice CT angiography pre- and postsuprarenal fixation of stent-grafts were selected for inclusion in the study. Eight juxtarenal models focusing on the renal arteries were generated from the multislice CT datasets. Four types of configurations of stent wires crossing the renal artery ostium were simulated in the segmented aorta models: a single wire crossing centrally, a single wire crossing peripherally, a V-shaped wire crossing centrally,more » and multiple wires crossing peripherally. The blood flow pattern, flow velocity, wall pressure, and wall shear stress at the renal arteries pre- and post-stent-grafting were analyzed and compared using a two-way fluid structure interaction analysis. The stent wire thickness was simulated with a diameter of 0.4, 1.0, and 2.0 mm, and hemodynamic analysis was performed at different cardiac cycles. The interference of stent wires with renal blood flow was mainly determined by the thickness of stent wires and the type of configuration of stent wires crossing the renal ostium. The flow velocity was reduced by 20-30% in most of the situations when the stent wire thickness increased to 1.0 and 2.0 mm. Of the four types of configuration, the single wire crossing centrally resulted in the highest reduction of flow velocity, ranging from 21% to 28.9% among three different wire thicknesses. Wall shear stress was also dependent on the wire thickness, which decreased significantly when the wire thickness reached 1.0 and 2.0 mm. In conclusion, our preliminary study showed that the hemodynamic effect of suprarenal stent wires in patients with AAA treated with suprarenal stent-grafts was determined by the thickness of suprarenal stent wires. Research findings in our study are useful for follow-up of patients treated with suprarenal stent-grafts to ensure long-term safety of the suprarenal fixation.« less
Multi-service small-cell cloud wired/wireless access network based on tunable optical frequency comb
NASA Astrophysics Data System (ADS)
Xiang, Yu; Zhou, Kun; Yang, Liu; Pan, Lei; Liao, Zhen-wan; Zhang, Qiang
2015-11-01
In this paper, we demonstrate a novel multi-service wired/wireless integrated access architecture of cloud radio access network (C-RAN) based on radio-over-fiber passive optical network (RoF-PON) system, which utilizes scalable multiple- frequency millimeter-wave (MF-MMW) generation based on tunable optical frequency comb (TOFC). In the baseband unit (BBU) pool, the generated optical comb lines are modulated into wired, RoF and WiFi/WiMAX signals, respectively. The multi-frequency RoF signals are generated by beating the optical comb line pairs in the small cell. The WiFi/WiMAX signals are demodulated after passing through the band pass filter (BPF) and band stop filter (BSF), respectively, whereas the wired signal can be received directly. The feasibility and scalability of the proposed multi-service wired/wireless integrated C-RAN are confirmed by the simulations.
Chen, Yu-Gene T.
2013-04-16
A method includes receiving a message at a first wireless node. The first wireless node is associated with a first wired network, and the first wired network is associated with a first security layer. The method also includes transmitting the message over the first wired network when at least one destination of the message is located in the first security layer. The method further includes wirelessly transmitting the message for delivery to a second wireless node when at least one destination of the message is located in a second security layer. The second wireless node is associated with a second wired network, and the second wired network is associated with the second security layer. The first and second security layers may be associated with different security paradigms and/or different security domains. Also, the message could be associated with destinations in the first and second security layers.
Oscillating-flow regenerator test rig: Woven screen and metal felt results
NASA Technical Reports Server (NTRS)
Gedeon, D.; Wood, J. G.
1992-01-01
We present correlating expressions, in terms of Reynolds or Peclet numbers, for friction factors, Nusselt numbers, enhanced axial conduction ratios, and overall heat flux ratios in four porous regenerator samples representative of stirling cycle regenerators: two woven screen samples and two random wire samples. Error estimates and comparison of data with others suggest our correlations are reliable, but we need to test more samples over a range of porosities before our results will become generally useful.
Babu, K Pradeep; Keerthi, V Naga; Madathody, Deepika; Prasanna, A Laxmi; Gopinath, Vidhya; Kumar, M Senthil; Kumar, A Nanda
2016-05-01
Recent metallurgical research and advancement in material science has benefited orthodontists in the selection of an appropriate wire size and alloy type, which is necessary to provide an optimum and predictable treatment results. The purpose of the study was to clinically evaluate and compare the surface characteristics of 16 x 22 stainless steel, Titanium molybdenum alloy, timolium, and titanium-niobium before and after placing them in a patient's mouth for 3 months using a scanning electron microscope (SEM). The total sample size was 40, which were divided into four groups (group 1 - stainless steel wires, 10 samples, group 2 - TMA wires, 10 samples, group 3 - timolium wires, 10 samples, and group 4 - titanium-niobium wires, 10 samples), and these were further subdivided into 5 each. The first subgroup of five samples was placed in the patient's mouth and was evaluated under SEM, and another subgroup of five samples was directly subjected to the SEM. Scanning electron microscopic evaluation of surface characteristics of unused 16 x 22 rectangular stainless steel wire under 500 x magnification showed an overall smooth surface. Stainless steel wire samples placed in the patient's mouth showed black hazy patches, which may be interoperated as areas of stress. TMA unused wires showed multiple small voids of areas and small craters with fewer elevated regions. The TMA wire samples placed in the patient's mouth showed black hazy patches and prominent ridges, making the wire rougher. Timolium unused archwires showed heavy roughness and voids, whereas wires tested in the patient's mouth showed homogeneous distribution of deep cracks and craters. Unused titanium-niobium archwires showed uniform prominent striations and ridges with occasional voids, whereas wires used in the patient's mouth showed prominent huge voids that could be interpreted as maximum stress areas. Stainless steel (group 1) used and unused wires showed smooth surface characteristics when compared with all the other three groups followed by timolium, which was superior to titanium-niobium wires and TMA wires. Timolium wires are superior to titanium-niobium wires and TMA wires.
Scale-up of 2G wire manufacturing at American Superconductor Corporation
NASA Astrophysics Data System (ADS)
Fleshler, S.; Buczek, D.; Carter, B.; Cedrone, P.; DeMoranville, K.; Gannon, J.; Inch, J.; Li, X.; Lynch, J.; Otto, A.; Podtburg, E.; Roy, D.; Rupich, M.; Sathyamurthy, S.; Schreiber, J.; Thieme, C.; Thompson, E.; Tucker, D.; Nagashima, K.; Ogata, M.
2009-10-01
American Superconductor Corporation (AMSC) has developed the base technology and a manufacturing line for initial volume production of low-cost second generation high temperature superconductor (2G HTS) wire for commercial and military applications. The manufacturing line is based on reel-to-reel processing of wide HTS strips using rolling assisted bi-axially textured substrate (RABiTS™) for the template and Metal Organic Deposition (MOD) for the HTS layer. AMSC’s wide strip process is a low cost manufacturing technology since multiple wires are produced in a single manufacturing pass by slitting the wide strip to narrower width in the last stage of the manufacturing process. Industry standard 4.4 mm wide wires are produced by laminating metallic foils, such as copper, stainless steel or any other material, to the HTS insert wire, and are chosen to tailor the electrical, thermal and mechanical properties of the wire for specific applications. The laminated, 4.4 mm wide wires are known as “344 superconductors.” In this paper, we summarize the status of AMSC’s manufacturing capability, the performance of the wire presently being produced, as well as the cost and technical advantages of AMSC’s manufacturing approach. In addition, future direction for research and development to improve electrical performance is presented.
Ag paste-based nanomesh electrodes for large-area touch screen panels
NASA Astrophysics Data System (ADS)
Chung, Sung-il; Kyeom Kim, Pan; Ha, Tae-gyu
2017-10-01
This study reports a novel method for fabricating a nickel nanomesh mold using phase shift lithography, suitable for use in large-area touch screen panel applications. Generally, the values of light transmittance and sheet resistance of metal mesh transparent conducting electrode (TCE) films are determined by the ratio of the aperture to metal areas. In this study, taking into consideration the optimal light transmittance, sheet resistance, and pattern visibility issues, the line width of the metal mesh pattern was ~1 µm, and the pitch of the pattern was ~100 µm. In addition, a novel method of manufacturing wiring electrodes using a phase shift lithography process was also developed and evaluated. A TCE film with a size of 370 mm × 470 mm was prepared and evaluated for its light transmittance and sheet resistance. In addition, wiring electrodes with a length of 70 mm were fabricated and their line resistances evaluated by varying their line width.
Monte Carlo design of optimal wire mesh collimator for breast tumor imaging process
NASA Astrophysics Data System (ADS)
Saad, W. H. M.; Roslan, R. E.; Mahdi, M. A.; Choong, W.-S.; Saion, E.; Saripan, M. I.
2011-08-01
This paper presents the modeling of breast tumor imaging process using wire mesh collimator gamma camera. Previous studies showed that the wire mesh collimator has a potential to improve the sensitivity of the tumor detection. In this paper, we extend our research significantly, to find an optimal configuration of the wire mesh collimator specifically for semi-compressed breast tumor detection, by looking into four major factors: weight, sensitivity, spatial resolution and tumor contrast. The numbers of layers in the wire mesh collimator is varied to optimize the collimator design. The statistical variations of the results are studied by simulating multiple realizations for each experiment using different starting random numbers. All the simulation environments are modeled using Monte Carlo N-Particle Code (MCNP). The quality of the detection is measured directly by comparing the sensitivity, spatial resolution and tumor contrast of the images produced by the wire mesh collimator and benchmarked that with a standard multihole collimator. The proposed optimal configuration of the wire mesh collimator is optimized by selecting the number of layers in wire mesh collimator, where the tumor contrast shows a relatively comparable value to the multihole collimator, when it is tested with uniformly semi-compressed breast phantom. The wire mesh collimator showed higher number of sensitivity because of its loose arrangement while the spatial resolution of wire mesh collimator does not shows much different compared to the multihole collimator. With a relatively good tumor contrast and spatial resolution, and increased in sensitivity, a new proposed wire mesh collimator gives a significant improvement in the wire mesh collimator design for breast cancer imaging process. The proposed collimator configuration is reduced to 44.09% from the total multihole collimator weight.
NASA Technical Reports Server (NTRS)
Papazian, Peter B.; Perala, Rodney A.; Curry, John D.; Lankford, Alan B.; Keller, J. David
1988-01-01
Using three different current injection methods and a simple voltage probe, transfer impedances for Solid Rocket Motor (SRM) joints, wire meshes, aluminum foil, Thorstrand and a graphite composite motor case were measured. In all cases, the surface current distribution for the particular current injection device was calculated analytically or by finite difference methods. The results of these calculations were used to generate a geometric factor which was the ratio of total injected current to surface current density. The results were validated in several ways. For wire mesh measurements, results showed good agreement with calculated results for a 14 by 18 Al screen. SRM joint impedances were independently verified. The filiment wound case measurement results were validated only to the extent that their curve shape agrees with the expected form of transfer impedance for a homogeneous slab excited by a plane wave source.
Electrostatic potential profiles of molecular conductors
NASA Astrophysics Data System (ADS)
Liang, G. C.; Ghosh, A. W.; Paulsson, M.; Datta, S.
2004-03-01
The electrostatic potential across a short ballistic molecular conductor depends sensitively on the geometry of its environment, and can affect its conduction significantly by influencing its energy levels and wave functions. We illustrate some of the issues involved by evaluating the potential profiles for a conducting gold wire and an aromatic phenyl dithiol molecule in various geometries. The potential profile is obtained by solving Poisson’s equation with boundary conditions set by the contact electrochemical potentials and coupling the result self-consistently with a nonequilibrium Green’s function formulation of transport. The overall shape of the potential profile (ramp versus flat) depends on the feasibility of transverse screening of electric fields. Accordingly, the screening is better for a thick wire, a multiwalled nanotube, or a close-packed self-assembled monolayer, in comparison to a thin wire, a single-walled nanotube, or an isolated molecular conductor. The electrostatic potential further governs the alignment or misalignment of intramolecular levels, which can strongly influence the molecular current voltage (I V) characteristic. An external gate voltage can modify the overall potential profile, changing the I V characteristic from a resonant conducting to a saturating one. The degree of saturation and gate modulation depends on the availability of metal-induced-gap states and on the electrostatic gate control parameter set by the ratio of the gate oxide thickness to the channel length.
NASA Astrophysics Data System (ADS)
Al-Rashid, Md Mamun; Maqableh, Mazin; Stadler, Bethanie; Atulasimha, Jayasimha
High density arrays of electrodeposited nanowires consisting of ferromagnetic/non-magnetic (Co/Cu) multilayers are promising as magnetic memory devices. For individual nanowires containing multiple (Co/Cu) bilayers, the stable magnetization orientations of the Co layers (with respect to each other and the nanowire axis) are dependent on the Cu layer thickness, even when the Co layer dimensions are fixed. This dependence is a result of the competition between shape anisotropy, magneto-crystalline anisotropy and intra-wire dipole coupling. However, when the nanowires are closely packed in arrays, inter-wire dipole coupling can result in complex and tunable domain structures comprising segments of multiple nanowires. This work explores the dependence of these domain structures and their switching on the non-magnetic layer thickness and intra-wire spacing both experimentally and via rigorous micromagnetic simulation. These domain structures play a crucial role in determining the current and time required for STT switching. NSF CAREER Grant CCF-1253370.
A hydrodynamic model of the oscillating screen viscometer
NASA Technical Reports Server (NTRS)
Davis, A. M. J.
1993-01-01
The viscometer consists of an oscillating screen immersed in a fluid and free to rotate about an axis in its plane. The viscosity can be determined from the measured ratio of the periodic driving force to the screen motion when an adequate hydrodynamical model of the immersed oscillator is available. The screen is formed by a square mesh of thin wire whose dimensions invite comparison with asymptotic results for narrow hollow bodies translating in Stokes flow. These indicate that the closed hole structure of the grid plays an important role in determining its motion. It is shown that this role diminishes as the frequency increases. The computed results, obtained from a system of linear equations, are consistent with experimental values over the appropriate range of frequency.
Materials for Space Exploration
NASA Technical Reports Server (NTRS)
Robertson, Luke B.; Williams, Martha
2010-01-01
Topics include a lab overview, testing and processing equipment, hemochromic hydrogen sensors, antimicrobial materials, wire system materials, CNT ink formulations, CNT ink dust screens, CNT ink printed circuitry, cryogenic materials development, fire and polymers, the importance of lighting, electric lighting systems, LED for plant growth, and carbon nanotube fiber filaments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lv, Mei; Liu, Zengrong; He, Bing
In previous studies, we reported molecular dynamics (MD) simulations showing that single-file water wires confined inside Y-shaped single-walled carbon nanotubes (Y-SWNTs) held strong and robust capability to convert and multiply charge signals [Y. S. Tu, P. Xiu, R. Z. Wan, J. Hu, R. H. Zhou, and H. P. Fang, Proc. Natl. Acad. Sci. U.S.A. 106, 18120 (2009); Y. Tu, H. Lu, Y. Zhang, T. Huynh, and R. Zhou, J. Chem. Phys. 138, 015104 (2013)]. It is fascinating to see whether the signal multiplication can be realized by other kinds of polar molecules with larger dipole moments (which make the experimentalmore » realization easier). In this article, we use MD simulations to study the urea-mediated signal conversion and multiplication with Y-SWNTs. We observe that when a Y-SWNT with an external charge of magnitude 1.0 e (the model of a signal at the single-electron level) is solvated in 1 M urea solutions, urea can induce drying of the Y-SWNT and fill its interiors in single-file, forming Y-shaped urea wires. The external charge can effectively control the dipole orientation of the urea wire inside the main channel (i.e., the signal can be readily converted), and this signal can further be multiplied into 2 (or more) output signals by modulating dipole orientations of urea wires in bifurcated branch channels of the Y-SWNT. This remarkable signal transduction capability arises from the strong dipole-induced ordering of urea wires under extreme confinement. We also discuss the advantage of urea as compared with water in the signal multiplication, as well as the robustness and biological implications of our findings. This study provides the possibility for multiplying signals by using urea molecules (or other polar organic molecules) with Y-shaped nanochannels and might also help understand the mechanism behind signal conduction in both physical and biological systems.« less
Noise Identification in a Hot Transonic Jet Using Low-Dimensional Methods
2008-03-01
calibration between the nozzle static pressure (transducer) and total pressure ( pitot probe) reveals a nearly linear relationship between the two, exhibiting... rakes of hot-wires. Multi-point correlations of velocity components coupled with assumptions of homogeneity and periodicity in the jet flow flied...axisymmetric incompressible jet at one downstream position using an in-house designed rake of 138 hot-wires. The experiment was then carried out at multiple
The effect of zinc oxide nanoparticles deposition for friction reduction on orthodontic wires
Kachoei, Mojghan; Eskandarinejad, Faranak; Divband, Baharak; Khatamian, Masumeh
2013-01-01
Background: In the sliding technique, the reduced frictional forces are associated with rapid tooth movements and better control of the anchorage. Recently, wire coating with different nanoparticles has been proposed to decrease frictional forces. This in vitro study was carried out to coat stainless steel (SS) wires with zinc oxide (ZnO) nanoparticles in order to determine the effect of this coating on friction between wires and orthodontic brackets. Materials and Methods: Eighty 0.016 inch and 0.019 inch × 0.025 inch SS wires with and without ZnO nanoparticles were used in 80 orthodontic brackets (0.018 and 0.022 systems). The coated wires were analyzed by SEM and X-Ray diffraction (XRD) observations. Kinetic friction between the wires and orthodontic brackets were calculated using a universal testing machine. Frictional forces were statistically analyzed using three-way ANOVA, one-way ANOVA, Student's t-test and Tukey multiple comparison tests. Results: Coating with ZnO nanoparticles significantly influenced frictional force values (P < 0.0001). In 0.019 inch × 0.025 inch wires, the frictional forces were 1.6912 ± 0.18868 and 3.4485 ± 0.32389 N in the coated and uncoated wires respectively, (51% reductions). In the 0.016 inch wires, the friction values were estimated to be 1.5668 ± 0.10703 and 2.56 ± 0.34008 N in the coated and uncoated conditions, respectively, (39% reductions). Conclusion: Due to the positive effects of ZnO nanoparticle coating on decreasing frictional forces, these nanoparticles might offer a novel opportunity to significantly reduce friction during tooth movement. PMID:24130586
Kalia, Anoop; Khatri, Kavin; Singh, Jagdeep; Bansal, Kapil; Sagy, Mohammed
2016-01-01
Introduction: The migration of circlage wires used in tension band wiring construct of patella fractures in the posterior soft tissue envelope surrounding the knee joint has been rarely reported. Case Presentation: A 60-year-old woman presented to us with pain over medial aspect of right knee joint. She underwent open reduction and internal fixation for a patellar fracture which she sustained 4 years back and subsequently underwent kirschner wire(k wire) removal for the same around 2 years back. X-rays of the knee joint shows that the circlage wire used in tension band construct which was left in place had broken into multiple pieces and was lying in the soft tissue envelope surrounding the knee joint and one piece migrate to the popliteal fossa. On examination patient did not had distal neuro-vascular deficit. The pain of the patient was due to the osteo-arthritic changes in her medial side of knee joint rather than broken wire pieces. Patient was advised to undergo total knee replacement along with subsequent removal of broken wires but patient refused for any type of surgery and is kept on regular follow up Conclusion: This case report summarizes a rare complication resulting from hardware failure used for fixing patella fractures and throws a light on potential unwarned complications due to broken wires along with early recogonition and removal of broken hardware by surgeons. PMID:28116277
Composite ceramic superconducting wires for electric motor applications
NASA Astrophysics Data System (ADS)
Halloran, John W.
1990-07-01
Several types of HTSC wire have been produced and two types of HTSC motors are being built. Hundreds of meters of Ag- clad wire were fabricated from YBa2Cu3O(7-x) (Y-123) and Bi2Ca2Sr2Cu3O10 (BiSCCO). The dc homopolar motor coils are not yet completed, but multiple turns of wire have been wound on the coil bobbins to characterize the superconducting properties of coiled wire. Multifilamentary conductors were fabricated as cables and coils. The sintered polycrystalline wire has self-field critical current densities (Jc) as high as 2800 A/sq cm, but the Jc falls rapidly with magnetic field. To improve Jc, sintered YBCO wire is melt textured with a continuous process which has produced textures wire up to 0.5 meters long with 77K transport Jc above 11, 770 A/sq cm2 in self field and 2100 A/sq cm2 at 1 telsa. The Emerson Electric dc homopolar HTSC motor has been fabricated and run with conventional copper coils. A novel class of potential very powerful superconducting motors have been designed to use trapped flux in melt textures Y-123 as magnet replicas in an new type of permanent magnet motor. The stator element and part of the rotor of the first prototype machine exist, and the HTSC magnet replica segments are being fabricated.
Silicon-fiber blanket solar-cell array concept
NASA Technical Reports Server (NTRS)
Eliason, J. T.
1973-01-01
Proposed economical manufacture of solar-cell arrays involves parallel, planar weaving of filaments made of doped silicon fibers with diffused radial junction. Each filament is a solar cell connected either in series or parallel with others to form a blanket of deposited grids or attached electrode wire mesh screens.
Detail of dipole antenna element (right) and 94' lowband reflector ...
Detail of dipole antenna element (right) and 94' low-band reflector screen poles (left), note the guy wires from the antenna element, view facing north northeast - U.S. Naval Base, Pearl Harbor, Naval Radio Station, AF/FRD-10 Circularly Disposed Antenna Array, Wahiawa, Honolulu County, HI
46 CFR 162.017-6 - Procedure for approval.
Code of Federal Regulations, 2014 CFR
2014-10-01
... and size of wire of flame screens. (c) Pre-approval tests. Before approval is granted, the... desiring approval of a new design or type of pressure-vacuum relief valve shall submit drawings in quadruplicate showing the design of the valve, the sizes for which approval is requested, method of operation...
46 CFR 162.017-6 - Procedure for approval.
Code of Federal Regulations, 2013 CFR
2013-10-01
... and size of wire of flame screens. (c) Pre-approval tests. Before approval is granted, the... desiring approval of a new design or type of pressure-vacuum relief valve shall submit drawings in quadruplicate showing the design of the valve, the sizes for which approval is requested, method of operation...
46 CFR 162.017-6 - Procedure for approval.
Code of Federal Regulations, 2012 CFR
2012-10-01
... and size of wire of flame screens. (c) Pre-approval tests. Before approval is granted, the... desiring approval of a new design or type of pressure-vacuum relief valve shall submit drawings in quadruplicate showing the design of the valve, the sizes for which approval is requested, method of operation...
Needleless electrospinning with twisted wire spinneret
NASA Astrophysics Data System (ADS)
Holopainen, Jani; Penttinen, Toni; Santala, Eero; Ritala, Mikko
2015-01-01
A needleless electrospinning setup named ‘Needleless Twisted Wire Electrospinning’ was developed. The polymer solution is electrospun from the surface of a twisted wire set to a high voltage and collected on a cylindrical collector around the wire. Multiple Taylor cones are simultaneously self-formed on the downward flowing solution. The system is robust and simple with no moving parts aside from the syringe pump used to transport the solution to the top of the wire. The structure and process parameters of the setup and the results on the preparation of polyvinyl pyrrolidone (PVP), hydroxyapatite (HA) and bioglass fibers with the setup are presented. PVP fiber sheets with areas of 40 × 120 cm2 and masses up to 1.15 g were prepared. High production rates of 5.23 g h-1 and 1.40 g h-1 were achieved for PVP and HA respectively. The major limiting factor of the setup is drying of the polymer solution on the wire during the electrospinning process which will eventually force to interrupt the process for cleaning of the wire. Possible solutions to this problem and other ways to develop the setup are discussed. The presented system provides a simple way to increase the production rate and area of fiber sheet as compared with the conventional needle electrospinning.
Shi, Minjie; Yang, Cheng; Song, Xuefeng; Liu, Jing; Zhao, Liping; Zhang, Peng; Gao, Lian
2017-05-24
Wire-shaped supercapacitors (SCs) based on shape memory materials are of considerable interest for next-generation portable and wearable electronics. However, the bottleneck in this field is how to develop the devices with excellent electrochemical performance while well-maintaining recoverability and flexibility. Herein, a unique asymmetric electrode concept is put forward to fabricate smart wire-shaped SCs with ultrahigh energy density, which is realized by using porous carbon dodecahedra coated on NiTi alloy wire and flexible graphene fiber as yarn electrodes. Notably, the wire-shaped SCs not only exhibit high flexibility that can be readily woven into real clothing but also represent the available recoverable ability. When irreversible plastic deformations happen, the deformed shape of the devices can automatically resume the initial predesigned shape in a warm environment (about 35 °C). More importantly, the wire-shaped SCs act as efficient energy storage devices, which display high volumetric energy density (8.9 mWh/cm 3 ), volumetric power density (1080 mW/cm 3 ), strong durability in multiple mechanical states, and steady electrochemical behavior after repeated shape recovery processes. Considering their relative facile fabrication technology and excellent electrochemical performance, this asymmetric electrode strategy produced smart wire-shaped supercapacitors desirable for multifunctional portable and wearable electronics.
Miniature High-Force, Long-Stroke SMA Linear Actuators
NASA Technical Reports Server (NTRS)
Cummin, Mark A.; Donakowski, William; Cohen, Howard
2008-01-01
Improved long-stroke shape-memory-alloy (SMA) linear actuators are being developed to exert significantly higher forces and operate at higher activation temperatures than do prior SMA actuators. In these actuators, long linear strokes are achieved through the principle of displacement multiplication, according to which there are multiple stages, each intermediate stage being connected by straight SMA wire segments to the next stage so that relative motions of stages are additive toward the final stage, which is the output stage. Prior SMA actuators typically include polymer housings or shells, steel or aluminum stages, and polymer pads between successive stages of displacement-multiplication assemblies. Typical output forces of prior SMA actuators range from 10 to 20 N, and typical strokes range from 0.5 to 1.5 cm. An important disadvantage of prior SMA wire actuators is relatively low cycle speed, which is related to actuation temperature as follows: The SMA wires in prior SMA actuators are typically made of a durable nickel/titanium alloy that has a shape-memory activation temperature of 80 C. An SMA wire can be heated quickly from below to above its activation temperature to obtain a stroke in one direction, but must then be allowed to cool to somewhat below its activation temperature (typically, less than or equal to 60 C in the case of an activation temperature of 80 C) to obtain a stroke in the opposite direction (return stroke). At typical ambient temperatures, cooling times are of the order of several seconds. Cooling times thus limit cycle speeds. Wires made of SMA alloys having significantly higher activation temperatures [denoted ultra-high-temperature (UHT) SMA alloys] cool to the required lower return-stroke temperatures more rapidly, making it possible to increase cycle speeds. The present development is motivated by a need, in some applications (especially aeronautical and space-flight applications) for SMA actuators that exert higher forces, operate at greater cycle speeds, and have stronger housings that can withstand greater externally applied forces and impacts. The main novel features of the improved SMA actuators are the following: 1) The ends of the wires are anchored in compact crimps made from short steel tubes. Each wire end is inserted in a tube, the tube is flattened between planar jaws to make the tube grip the wire, the tube is compressed to a slight U-cross-section deformation to strengthen the grip, then the crimp is welded onto one of the actuator stages. The pull strength of a typical crimp is about 125 N -- comparable to the strength of the SMA wire and greater than the typical pull strengths of wire-end anchors in prior SMA actuators. Greater pull strength is one of the keys to achievement of higher actuation force; 2) For greater strength and resistance to impacts, housings are milled from aluminum instead of being made from polymers. Each housing is made from two pieces in a clamshell configuration. The pieces are anodized to reduce sliding friction; 3) Stages are made stronger (to bear greater compression loads without excessive flexing) by making them from steel sheets thicker than those used in prior SMA actuators. The stages contain recessed pockets to accommodate the crimps. Recessing the pockets helps to keep overall dimensions as small as possible; and, 4) UHT SMA wires are used to satisfy the higher-speed/higher-temperature requirement.
Coupled resonator optical waveguides based on silicon-on-insulator photonic wires
NASA Astrophysics Data System (ADS)
Xia, Fengnian; Sekaric, Lidija; O'Boyle, Martin; Vlasov, Yurii
2006-07-01
Coupled resonator optical waveguides (CROWs) comprised of up to 16 racetrack resonators based on silicon-on-insulator (SOI) photonic wires were fabricated and characterized. The optical properties of the CROWs were simulated using measured single resonator parameters based on a matrix approach. The group delay property of CROWs was also analyzed. The SOI based CROWs consisting of multiple resonators have extremely small footprints and can find applications in optical filtering, dispersion compensation, and optical buffering. Moreover, such CROW structure is a promising candidate for exploration of low light level nonlinear optics due to its resonant nature and compact mode size (˜0.1μm2) in photonic wire.
Song, Hyung Keun; Yoo, Je Hyun; Byun, Young Soo; Yang, Kyu Hyun
2014-05-01
Among patients over 50 years of age, separate vertical wiring alone may be insufficient for fixation of fractures of the inferior pole of the patella. Therefore, mechanical and clinical studies were performed in patients over the age of 50 to test the strength of augmentation of separate vertical wiring with cerclage wire (i.e., combined technique). Multiple osteotomies were performed to create four-part fractures in the inferior poles of eight pairs of cadaveric patellae. One patella from each pair was fixed with the separate wiring technique, while the other patella was fixed with a combined technique. The ultimate load to failure and stiffness of the fixation were subsequently measured. In a clinical study of 21 patients (average age of 64 years), comminuted fractures of the inferior pole of the patellae were treated using the combined technique. Operative parameters were recorded from which post-operative outcomes were evaluated. For cadaveric patellae, whose mean age was 69 years, the mean ultimate loads to failure for the separate vertical wiring technique and the combined technique were 216.4±72.4 N and 324.9±50.6 N, respectively (p=0.012). The mean stiffness for the separate vertical wiring technique and the combined technique was 241.1±68.5 N/mm and 340.8±45.3 N/mm, respectively (p=0.012). In the clinical study, the mean clinical score at final follow-up was 28.1 points. Augmentation of separate vertical wiring with cerclage wire provides enough strength for protected early exercise of the knee joint and uneventful healing.
A generalized analytical approach to the coupled effect of SMA actuation and elastica deflection
NASA Astrophysics Data System (ADS)
Sreekumar, M.; Singaperumal, M.
2009-11-01
A compliant miniature parallel manipulator made of superelastic nitinol pipe as its central pillar and actuated by three symmetrically attached shape memory alloy (SMA) wires is under development. The mobility for the platform is obtained by the selective actuation of one or two wires at a time. If one wire is actuated, the other two unactuated wires provide the counter effect. Similarly, if two wires are actuated simultaneously or in a differential manner, the third unactuated wire resists the movement of the platform. In an earlier work of the authors, the static displacement analysis was presented without considering the effect of unactuated wires. In this contribution, the force-displacement analysis is presented considering the effect of both actuated and unactuated wires. Subsequently, an attempt has been made to obtain a generalized approach from which six types of actuation methods are identified using a group of conditional parameters. Each method leads to a set of large deflection expressions suitable for a particular actuation method. As the large deflection expressions derived for the mechanism are nonlinear and involve interdependent parameters, their simplified form using a parametric approximation have also been obtained using Howell's algorithm. The generalized approach and the solution algorithm developed can be applied to any kind of compliant mechanism having large deflection capabilities, including planar and spatial MEMS devices and stability analysis of long slender columns supported by wires or cables. The procedure developed is also suitable for the static analysis of spatial compliant mechanisms actuated by multiple SMA actuators.
Assembly techniques for ultra-low mass drift chambers
NASA Astrophysics Data System (ADS)
Assiro, R.; Cascella, M.; Grancagnolo, F.; L'Erario, A.; Miccoli, A.; Rella, S.; Spedicato, M.; Tassielli, G.
2014-03-01
We presents a novel technique for the fast assembly of next generation ultra low mass drift chambers offering space point resolution of the order of 100 μm and high tolerance to pile-up. The chamber design has been developed keeping in mind the requirements for the search of rare processes: high resolutions (order of 100-200 KeV/c) for particles momenta in a range (50-100 MeV/c) totally dominated by the multiple scattering contribution (e.g., muon and kaon decay experiment such as MEG at PSI and Mu2e and ORKA at Fermilab). We describe a novel wiring strategy enabling the semiautomatic wiring of a complete layer with a high degree of control over wire tension and position. We also present feed-through-less wire anchoring system. These techniques have been already implemented at INFN-Lecce in the construction of a prototype drift chamber to be soon tested with cosmic rays and particle beams.
CCD Photometry of bright stars using objective wire mesh
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamiński, Krzysztof; Zgórz, Marika; Schwarzenberg-Czerny, Aleksander, E-mail: chrisk@amu.edu.pl
2014-06-01
Obtaining accurate photometry of bright stars from the ground remains problematic due to the danger of overexposing the target and/or the lack of suitable nearby comparison stars. The century-old method of using objective wire mesh to produce multiple stellar images seems promising for the precise CCD photometry of such stars. Furthermore, our tests on β Cep and its comparison star, differing by 5 mag, are very encouraging. Using a CCD camera and a 20 cm telescope with the objective covered by a plastic wire mesh, in poor weather conditions, we obtained differential photometry with a precision of 4.5 mmag permore » two minute exposure. Our technique is flexible and may be tuned to cover a range as big as 6-8 mag. We discuss the possibility of installing a wire mesh directly in the filter wheel.« less
Transmission line design for a power distribution system at 20 kHz for aircraft
NASA Technical Reports Server (NTRS)
Zelby, L. W.; Mathes, J. B.; Shawver, J. W.
1986-01-01
A low inductance, low characteristic impedance transmission line was designed for a 20 kHz power distribution system. Several different conductor configurations were considered: strip lines, interdigitated metal ribbons, and standard insulated wires in multiwire configurations (circular and rectangular cylindrical arrangements). The final design was a rectangular arrangement of multiple wires of the same gauge with alternating polarities from wire to wire. This offered the lowest inductance per unit length (on the order of several nanohenries/meter) and the lowest characteristic impedance (on the order of one Ohm). Standard multipin connectors with gold-plated elements were recommended with this transmission line, the junction boxes to be internally connected with flat metal ribbons for low inductance, and the line to be constructed in sections of suitable length. Computer programs for the calculation of inductance of multiwire lines and of capacitances of strip lines were developed.
A screen-printed flexible flow sensor
NASA Astrophysics Data System (ADS)
Moschos, A.; Syrovy, T.; Syrova, L.; Kaltsas, G.
2017-04-01
A thermal flow sensor was printed on a flexible plastic substrate using exclusively screen-printing techniques. The presented device was implemented with custom made screen-printed thermistors, which allows simple, cost-efficient production on a variety of flexible substrates while maintaining the typical advantages of thermal flow sensors. Evaluation was performed for both static (zero flow) and dynamic conditions using a combination of electrical measurements and IR imaging techniques in order to determine important characteristics, such as temperature response, output repeatability, etc. The flow sensor was characterized utilizing the hot-wire and calorimetric principles of operation, while the preliminary results appear to be very promising, since the sensor was successfully evaluated and displayed adequate sensitivity in a relatively wide flow range.
Proportional counter radiation camera
Borkowski, C.J.; Kopp, M.K.
1974-01-15
A gas-filled proportional counter camera that images photon emitting sources is described. A two-dimensional, positionsensitive proportional multiwire counter is provided as the detector. The counter consists of a high- voltage anode screen sandwiched between orthogonally disposed planar arrays of multiple parallel strung, resistively coupled cathode wires. Two terminals from each of the cathode arrays are connected to separate timing circuitry to obtain separate X and Y coordinate signal values from pulse shape measurements to define the position of an event within the counter arrays which may be recorded by various means for data display. The counter is further provided with a linear drift field which effectively enlarges the active gas volume of the counter and constrains the recoil electrons produced from ionizing radiation entering the counter to drift perpendicularly toward the planar detection arrays. A collimator is interposed between a subject to be imaged and the counter to transmit only the radiation from the subject which has a perpendicular trajectory with respect to the planar cathode arrays of the detector. (Official Gazette)
Gallerani, Giulia; Cocchi, Claudia; Bocchini, Martine; Piccinini, Filippo; Fabbri, Francesco
2017-01-01
Circulating tumor cells (CTCs) are associated with poor survival in metastatic cancer. Their identification, phenotyping, and genotyping could lead to a better understanding of tumor heterogeneity and thus facilitate the selection of patients for personalized treatment. However, this is hampered because of the rarity of CTCs. We present an innovative approach for sampling a high volume of the patient blood and obtaining information about presence, phenotype, and gene translocation of CTCs. The method combines immunofluorescence staining and DNA fluorescent-in-situ-hybridization (DNA FISH) and is based on a functionalized medical wire. This wire is an innovative device that permits the in vivo isolation of CTCs from a large volume of peripheral blood. The blood volume screened by a 30-min administration of the wire is approximately 1.5-3 L. To demonstrate the feasibility of this approach, epithelial cell adhesion molecule (EpCAM) expression and the chromosomal translocation of the ALK gene were determined in non-small-cell lung cancer (NSCLC) cell lines captured by the functionalized wire and stained with an immuno-DNA FISH approach. Our main challenge was to perform the assay on a 3D structure, the functionalized wire, and to determine immuno-phenotype and FISH signals on this support using a conventional fluorescence microscope. The results obtained indicate that catching CTCs and analyzing their phenotype and chromosomal rearrangement could potentially represent a new companion diagnostic approach and provide an innovative strategy for improving personalized cancer treatments. PMID:29286485
A study of the factors affecting boundary layer two-dimensionality in wind tunnels
NASA Technical Reports Server (NTRS)
Mehta, R. D.; Hoffmann, P. H.
1986-01-01
The effect of screens, honeycombs, and centrifugal blowers on the two-dimensionality of a boundary layer on the test section floors of low-speed blower tunnels is studied. Surveys of the spanwise variation in surface shear stress in three blower tunnels revealed that the main component responsible for altering the spanwise properties of the test section boundary layer was the last screen, thus confirming previous findings. It was further confirmed that a screen with varying open-area ratio, produced an unstable flow. However, contrary to popular belief, it was also found that for given incoming conditions and a screen free of imperfections, its open-area ratio alone was not enough to describe its performance. The effect of other geometric parameters such as the type of screen, honeycomb, and blower were investigated. In addition, the effect of the order of components in the settling chamber, and of wire Reynolds number were also studied.
Using Storytelling to Hone Language Skills
ERIC Educational Resources Information Center
Snider, Michelle
2008-01-01
A first glance into the classroom where Phillip Tillery teaches may leave visitors overwhelmed due by the array of high-tech equipment wired and ready for access by his students. Some students are working independently at computers while others are immersed in teams at a green screen and motion-capture setup. Various computer programs with myriad…
46 CFR 194.10-25 - Ventilation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... and shall serve no other space. Weather cowls shall be provided with a double layer of wire screen of... temperature below 100 °F. with 88 °F. weather air. Mechanical cooling may be used where ventilation... 130 °F. with an assumed outside temperature of 115 °F. (2) Ventilation supply weather openings shall...
46 CFR 194.10-25 - Ventilation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... and shall serve no other space. Weather cowls shall be provided with a double layer of wire screen of... temperature below 100 °F. with 88 °F. weather air. Mechanical cooling may be used where ventilation... 130 °F. with an assumed outside temperature of 115 °F. (2) Ventilation supply weather openings shall...
46 CFR 194.10-25 - Ventilation.
Code of Federal Regulations, 2013 CFR
2013-10-01
... and shall serve no other space. Weather cowls shall be provided with a double layer of wire screen of... temperature below 100 °F. with 88 °F. weather air. Mechanical cooling may be used where ventilation... 130 °F. with an assumed outside temperature of 115 °F. (2) Ventilation supply weather openings shall...
46 CFR 194.10-25 - Ventilation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... and shall serve no other space. Weather cowls shall be provided with a double layer of wire screen of... temperature below 100 °F. with 88 °F. weather air. Mechanical cooling may be used where ventilation... 130 °F. with an assumed outside temperature of 115 °F. (2) Ventilation supply weather openings shall...
Multiple cell radiation detector system, and method, and submersible sonde
Johnson, Larry O.; McIsaac, Charles V.; Lawrence, Robert S.; Grafwallner, Ervin G.
2002-01-01
A multiple cell radiation detector includes a central cell having a first cylindrical wall providing a stopping power less than an upper threshold; an anode wire suspended along a cylindrical axis of the central cell; a second cell having a second cylindrical wall providing a stopping power greater than a lower threshold, the second cylindrical wall being mounted coaxially outside of the first cylindrical wall; a first end cap forming a gas-tight seal at first ends of the first and second cylindrical walls; a second end cap forming a gas-tight seal at second ends of the first and second cylindrical walls; and a first group of anode wires suspended between the first and second cylindrical walls.
Cinti, Filippo; Pisani, Guido; Vezzoni, Luca; Peirone, Bruno; Vezzoni, Aldo
2017-01-16
To evaluate the use of Kirschner wires for treatment of fractures of the lateral aspect of the humeral condyle in growing dogs. Retrospective analysis of 35 elbow fractures (33 dogs) of the lateral aspect of the humeral condyle treated by insertion of multiple transcondylar and one anti-rotational Kirschner wires. Radiographic and clinical re-evaluations were carried out immediately after surgery, at four weeks and, when required, at eight weeks postoperatively. Long-term follow-up was planned after a minimum of six months. The relationship between different implant configurations and clinical outcome was analysed statistically. Complete functional recovery was seen in 31 elbows (30 dogs), three elbows (2 dogs) had reduction in the range of motion, and one elbow (1 dog) had persistent grade 1 lameness two months postoperatively. Major complications occurred in eight elbows (8 dogs) and all were resolved by implant removal. Implant configuration did not affect outcome. Long-term evaluation in 12 cases with a mean follow-up of four years showed absence of lameness, normal function and no or mild radiographic evidence of osteoarthritis in 11 cases. Fracture of the lateral aspect of the humeral condyle in growing dogs can be successfully treated by multiple transcondylar convergent or parallel Kirschner wires, resulting in adequate fracture healing.
Ozcelikkale, Altug; Moon, Hye-Ran; Linnes, Michael; Han, Bumsoo
2017-09-01
Advances in nanotechnology have enabled numerous types of nanoparticles (NPs) to improve drug delivery to tumors. While many NP systems have been proposed, their clinical translation has been less than anticipated primarily due to failure of current preclinical evaluation techniques to adequately model the complex interactions between the NP and physiological barriers of tumor microenvironment. This review focuses on microfluidic tumor models for characterization of delivery efficacy and toxicity of cancer nanomedicine. Microfluidics offer significant advantages over traditional macroscale cell cultures by enabling recapitulation of tumor microenvironment through precise control of physiological cues such as hydrostatic pressure, shear stress, oxygen, and nutrient gradients. Microfluidic systems have recently started to be adapted for screening of drugs and NPs under physiologically relevant settings. So far the two primary application areas of microfluidics in this area have been high-throughput screening using traditional culture settings such as single cells or multicellular tumor spheroids, and mimicry of tumor microenvironment for study of cancer-related cell-cell and cell-matrix interactions. These microfluidic technologies are also useful in modeling specific steps in NP delivery to tumor and characterize NP transport properties and outcomes by systematic variation of physiological conditions. Ultimately, it will be possible to design drug-screening platforms uniquely tailored for individual patient physiology using microfluidics. These in vitro models can contribute to development of precision medicine by enabling rapid and patient-specific evaluation of cancer nanomedicine. WIREs Nanomed Nanobiotechnol 2017, 9:e1460. doi: 10.1002/wnan.1460 For further resources related to this article, please visit the WIREs website. © 2017 Wiley Periodicals, Inc.
Kumar, B Sunil; Miryala, Suresh; Kumar, K Kiran; Shameem, K; Regalla, Ravindra Reddy
2014-09-01
The orthodontist seeks an archwire-bracket combination that has both good biocompatibility and low friction. Hence, the aim of this multicenter in vitro study was to evaluate and compare the frictional resistance generated between titanium (Ti), stainless steel (SS), ceramic and ceramic with metal insert (CMI) brackets with SS wires of varying dimensions in a specially designed apparatus. The material used in this study were Ti, SS, Ceramic and CMI with 0.018″ slot manufactured with zero degree tip and -7° torque premolar brackets (3M, Unitek) and SS wires of varying dimensions (0.016″ round, 0.016 × 0.016″ square, 0.016 × 0.022″ rectangular and 0.017 × 0.025″ rectangular) used. The frictional resistance was measured using Instron Universal testing machine (Model no. 4301). The specimen population in each center composed each of 160 brackets and wires. Differences among the all bracket/wire combinations were tested using (one-way) ANOVA, followed by the student Newman Keuls multiple comparisons of means ranking (at P < 0.05) for the determination of differences among the groups. Ti bracket in combination with 0.017 × 0.025″ SS rectangular wire produced significant force levels for an optimum orthodontic movement with least frictional resistance. Ti brackets have least resistance and rectangular wires produced significant force. These can be used to avoid hazards of Nickel. SS brackets revealed higher static frictional force values as the wire dimension increased and showed lower static friction than Ti brackets for all wires except the thicker wire. Our study recommends the preclusion of brackets with rough surface texture (Ti brackets) with SS ligature wire for ligating bracket and archwire are better to reduce friction.
Song, Hyung Keun; Yoo, Je Hyun; Byun, Young Soo
2014-01-01
Purpose Among patients over 50 years of age, separate vertical wiring alone may be insufficient for fixation of fractures of the inferior pole of the patella. Therefore, mechanical and clinical studies were performed in patients over the age of 50 to test the strength of augmentation of separate vertical wiring with cerclage wire (i.e., combined technique). Materials and Methods Multiple osteotomies were performed to create four-part fractures in the inferior poles of eight pairs of cadaveric patellae. One patella from each pair was fixed with the separate wiring technique, while the other patella was fixed with a combined technique. The ultimate load to failure and stiffness of the fixation were subsequently measured. In a clinical study of 21 patients (average age of 64 years), comminuted fractures of the inferior pole of the patellae were treated using the combined technique. Operative parameters were recorded from which post-operative outcomes were evaluated. Results For cadaveric patellae, whose mean age was 69 years, the mean ultimate loads to failure for the separate vertical wiring technique and the combined technique were 216.4±72.4 N and 324.9±50.6 N, respectively (p=0.012). The mean stiffness for the separate vertical wiring technique and the combined technique was 241.1±68.5 N/mm and 340.8±45.3 N/mm, respectively (p=0.012). In the clinical study, the mean clinical score at final follow-up was 28.1 points. Conclusion Augmentation of separate vertical wiring with cerclage wire provides enough strength for protected early exercise of the knee joint and uneventful healing. PMID:24719149
Wiring economy and volume exclusion determine neuronal placement in the Drosophila brain.
Rivera-Alba, Marta; Vitaladevuni, Shiv N; Mishchenko, Yuriy; Mischenko, Yuriy; Lu, Zhiyuan; Takemura, Shin-Ya; Scheffer, Lou; Meinertzhagen, Ian A; Chklovskii, Dmitri B; de Polavieja, Gonzalo G
2011-12-06
Wiring economy has successfully explained the individual placement of neurons in simple nervous systems like that of Caenorhabditis elegans [1-3] and the locations of coarser structures like cortical areas in complex vertebrate brains [4]. However, it remains unclear whether wiring economy can explain the placement of individual neurons in brains larger than that of C. elegans. Indeed, given the greater number of neuronal interconnections in larger brains, simply minimizing the length of connections results in unrealistic configurations, with multiple neurons occupying the same position in space. Avoiding such configurations, or volume exclusion, repels neurons from each other, thus counteracting wiring economy. Here we test whether wiring economy together with volume exclusion can explain the placement of neurons in a module of the Drosophila melanogaster brain known as lamina cartridge [5-13]. We used newly developed techniques for semiautomated reconstruction from serial electron microscopy (EM) [14] to obtain the shapes of neurons, the location of synapses, and the resultant synaptic connectivity. We show that wiring length minimization and volume exclusion together can explain the structure of the lamina microcircuit. Therefore, even in brains larger than that of C. elegans, at least for some circuits, optimization can play an important role in individual neuron placement. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Flexible Screen Propellant Management Device (PMD) Demonstration With Cryogenic Liquid
NASA Technical Reports Server (NTRS)
Wollen, Mark; Bakke, Victor; Baker, James
2012-01-01
While evaluating various options for liquid methane and liquid oxygen propellant management for lunar missions, Innovative Engineering Solutions (IES) conceived the flexible screen device as a potential simple alternative to conventional propellant management devices (PMD). An apparatus was designed and fabricated to test flexible screen devices in liquid nitrogen. After resolution of a number of issues (discussed in detail in the paper), a fine mesh screen (325 by 2300 wires per inch) spring return assembly was successfully tested. No significant degradation in the screen bubble point was observed either due to the screen stretching process or due to cyclic fatigue during testing. An estimated 30 to 50 deflection cycles, and approximately 3 to 5 thermal cycles, were performed on the final screen specimen, prior to and between formally recorded testing. These cycles included some "abusive" pressure cycling, where gas or liquid was driven through the screen at rates that produced differential pressures across the screen of several times the bubble point pressure. No obvious performance degradation or other changes were observed over the duration of testing. In summary, it is felt by the author that these simple tests validated the feasibility of the flexible screen PMD concept for use with cryogenic propellants.
Long lifetimes of ultrahot particles in interacting Fermi systems
NASA Astrophysics Data System (ADS)
Bard, M.; Protopopov, I. V.; Mirlin, A. D.
2018-05-01
The energy dependence of the relaxation rate of hot electrons due to interaction with the Fermi sea is studied. We consider 2D and 3D systems, quasi-1D quantum wires with multiple transverse bands, as well as single-channel 1D wires. Our analysis includes both spinful and spin-polarized setups, with short-range and Coulomb interactions. We show that, quite generally, the relaxation rate is a nonmonotonic function of the electron energy and decays as a power law at high energies. In other words, ultrahot electrons regain their coherence with increasing energy. Such a behavior was observed in a recent experiment on multiband quantum wires, J. Reiner et al., Phys. Rev. X 7, 021016 (2017)., 10.1103/PhysRevX.7.021016
NASA Astrophysics Data System (ADS)
Assiro, R.; Cappelli, L.; Cascella, M.; De Lorenzis, L.; Grancagnolo, F.; Ignatov, F.; L'Erario, A.; Maffezzoli, A.; Miccoli, A.; Onorato, G.; Perillo, M.; Piacentino, G.; Rella, S.; Rossetti, F.; Spedicato, M.; Tassielli, G.; Zavarise, G.
2013-08-01
We present a novel low mass drift chamber concept, developed in order to fulfill the stringent requirements imposed by the experiments for extremely rare processes, which require high resolutions (order of 100-200 keV/c) for particle momenta in a range (50-100 MeV/c) totally dominated by the multiple scattering contribution. We describe a geometry optimization procedure and a new wiring strategy with a feed-through-less wire anchoring system developed and tested on a drift chamber prototype under completion at INFN-Lecce .
1989-01-01
prestrained Nitinol (an alloy of nickel and titanium) wires are embedded in an off-axis position in the graphite fiber reinforced epoxy composite beam... Nitinol ) alloy. Shape memory alloys have been applied to a number of items including connectors and heat engines, but have usually found application in... nitinol wire; the design includes prevention from ancillary jams. Miwa (1985) discusses the use of SMA actuator to sequential robotic control of multiple
Flightfax - Army Aviation Risk-Management Information. Volume 25, Number 11, August 1997. Snow
1997-08-01
but why haven’t Loach that would ensure our surviving a multiple- you been acknowledging the radio calls?" A quick wire strike. check confirmed that...helicopter upright with only the collective and Loach on post with skid shoes, the skid cleats would pedals. have snagged the middle wire and flipped...is more cost effective to overhaul until because masking violated FAA Mr. Ken Muzzo, DSN 490-2257 (314-260- the retirement life is reached. The
Diode probes for spatiotemporal optical control of multiple neurons in freely moving animals
Koos, Tibor; Buzsáki, György
2012-01-01
Neuronal control with high temporal precision is possible with optogenetics, yet currently available methods do not enable to control independently multiple locations in the brains of freely moving animals. Here, we describe a diode-probe system that allows real-time and location-specific control of neuronal activity at multiple sites. Manipulation of neuronal activity in arbitrary spatiotemporal patterns is achieved by means of an optoelectronic array, manufactured by attaching multiple diode-fiber assemblies to high-density silicon probes or wire tetrodes and implanted into the brains of animals that are expressing light-responsive opsins. Each diode can be controlled separately, allowing localized light stimulation of neuronal activators and silencers in any temporal configuration and concurrent recording of the stimulated neurons. Because the only connections to the animals are via a highly flexible wire cable, unimpeded behavior is allowed for circuit monitoring and multisite perturbations in the intact brain. The capacity of the system to generate unique neural activity patterns facilitates multisite manipulation of neural circuits in a closed-loop manner and opens the door to addressing novel questions. PMID:22496529
Comparison of joint designs for laser welding of cast metal plates and wrought wires.
Takayama, Yasuko; Nomoto, Rie; Nakajima, Hiroyuki; Ohkubo, Chikahiro
2013-01-01
The purpose of the present study was to compare joint designs for the laser welding of cast metal plates and wrought wire, and to evaluate the welded area internally using X-ray micro-focus computerized tomography (micro-CT). Cast metal plates (Ti, Co-Cr) and wrought wires (Ti, Co-Cr) were welded using similar metals. The specimens were welded using four joint designs in which the wrought wires and the parent metals were welded directly (two designs) or the wrought wires were welded to the groove of the parent metal from one or both sides (n = 5). The porosity and gap in the welded area were evaluated by micro-CT, and the maximum tensile load of the welded specimens was measured with a universal testing machine. An element analysis was conducted using an electron probe X-ray microanalyzer. The statistical analysis of the results was performed using Bonferroni's multiple comparisons (α = 0.05). The results included that all the specimens fractured at the wrought wire when subjected to tensile testing, although there were specimens that exhibited gaps due to the joint design. The wrought wires were affected by laser irradiation and observed to melt together and onto the filler metal. Both Mo and Sn elements found in the wrought wire were detected in the filler metal of the Ti specimens, and Ni was detected in the filler metal of the Co-Cr specimens. The four joint designs simulating the designs used clinically were confirmed to have adequate joint strength provided by laser welding.
Social Media in a Content Course for the Digital Natives
ERIC Educational Resources Information Center
Lie, Anita
2013-01-01
Digital technologies and the Internet have revolutionized the way people gather information and acquire new knowledge. With a click of a button or a touch on the screen, any person who is wired to the internet can access a wealth of information, ranging from books, poems, articles, graphics, animations and so much more. It is imperative that…
Simulated Laboratory in Digital Logic.
ERIC Educational Resources Information Center
Cleaver, Thomas G.
Design of computer circuits used to be a pencil and paper task followed by laboratory tests, but logic circuit design can now be done in half the time as the engineer accesses a program which simulates the behavior of real digital circuits, and does all the wiring and testing on his computer screen. A simulated laboratory in digital logic has been…
Monel-shot and screen regenerators
NASA Technical Reports Server (NTRS)
Browning, C. W.
1974-01-01
Monel has been found to be ideal material for matrix of regenerators operating in temperature range of 325 K to 50 K. Two best shapes are as spheres or as wire mesh. For given size of regenerator, spherical shots are preferable for low-temperature operation. At high temperatures, mesh would be superior by virtue of its lower flow resistance.
Innovative Chimney-Graft Technique for Endovascular Repair of a Pararenal Abdominal Aortic Aneurysm
Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A.
2015-01-01
After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta. PMID:25873796
Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.
Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir
2015-02-01
After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.
Background Acoustics Levels in the 9x15 Wind Tunnel and Linear Array Testing
NASA Technical Reports Server (NTRS)
Stephens, David
2011-01-01
The background noise level in the 9x15 foot wind tunnel at NASA Glenn has been documented, and the results compare favorably with historical measurements. A study of recessed microphone mounting techniques was also conducted, and a recessed cavity with a micronic wire mesh screen reduces hydrodynamic noise by around 10 dB. A three-microphone signal processing technique can provide additional benefit, rejecting up to 15 dB of noise contamination at some frequencies. The screen and cavity system offers considerable benefit to test efficiency, although there are additional calibration requirements.
A practical guide to the design and construction of a single wire beverage antenna
NASA Astrophysics Data System (ADS)
Spong, H. L.
1980-09-01
Theoretical results are presented which show the performance likely to result from using differing antenna heights, lengths and wire sizes and from operating with different ground conductivities. These studies were undertaken to provide practical advice for constructors and operators. Design parameters can be easily obtained with the aid of computer programs and an antenna can be rapidly constructed from readily available materials. Directivity can be increased by adding more elements, either in parallel or on a radial basis. A particular performance can be achieved with great latitude in the parameters. Good low angle performance can be achieved without large ground screens. A directional array can be made by switching between a number of elements set up on different bearings.
Catalytic igniters and their use to ignite lean hydrogen-air mixtures
McLean, William J.; Thorne, Lawrence R.; Volponi, Joanne V.
1988-01-01
A catalytic igniter which can ignite a hydrogen-air mixture as lean as 5.5% hydrogen with induction times ranging from 20 s to 400 s, under conditions which may be present during a loss-of-liquid-coolant accident at a light water nuclear reactor comprises (a) a perforate catalytically active substrate, such as a platinum coated ceramic honeycomb or wire mesh screen, through which heated gases produced by oxidation of the mixture can freely flow and (b) a plurality of thin platinum wires mounted in a thermally conductive manner on the substrate and positioned thereon so as to be able to receive heat from the substrate and the heated gases while also in contact with unoxidized gases.
A calibration loop to test hot-wire response under supercritical conditions
NASA Astrophysics Data System (ADS)
Radulović, Ivana; Vukoslavčević, P. V.; Wallace, J. M.
2004-11-01
A calibration facility to test the response of hot-wires in CO2 flow under supercritical conditions has been designed and constructed. It is capable of inducing variable speeds at different temperatures and pressures in the ranges of 0.15 - 2 m/s, 15 - 70 deg. C and 1 - 100 bar. The facility is designed as a closed loop with a test section, pump, electrical heater, DC motor and different regulating and measuring devices. The test section is a small tunnel, with a diffuser, honeycomb, screens and a nozzle to provide a uniform flow with a low turbulence level. The speed variation is created by a sealed, magnetic driven gear pump, with a variable rpm DC motor. Using the electrical heater and regulating the amount of CO2 in the facility, the desired temperature and pressure can be reached. The dimensions of the instalation are minimized to reduce the heat, pump power required, and CO2 consumption and to optimize safety. Preliminary testing of a single hot-wire velocity sensor at constant pressure (80 bar) and variable speed and temperature will be briefly described. The hot-wire probes calibrated in this loop will be used to measure turbulence properties in supercritical CO2 in support of improved designs of nuclear reactors to be cooled by supercritical fluids.
Small molecules targeting viral RNA.
Hermann, Thomas
2016-11-01
Highly conserved noncoding RNA (ncRNA) elements in viral genomes and transcripts offer new opportunities to expand the repertoire of drug targets for the development of antiinfective therapy. Ligands binding to ncRNA architectures are able to affect interactions, structural stability or conformational changes and thereby block processes essential for viral replication. Proof of concept for targeting functional RNA by small molecule inhibitors has been demonstrated for multiple viruses with RNA genomes. Strategies to identify antiviral compounds as inhibitors of ncRNA are increasingly emphasizing consideration of drug-like properties of candidate molecules emerging from screening and ligand design. Recent efforts of antiviral lead discovery for RNA targets have provided drug-like small molecules that inhibit viral replication and include inhibitors of human immunodeficiency virus (HIV), hepatitis C virus (HCV), severe respiratory syndrome coronavirus (SARS CoV), and influenza A virus. While target selectivity remains a challenge for the discovery of useful RNA-binding compounds, a better understanding is emerging of properties that define RNA targets amenable for inhibition by small molecule ligands. Insight from successful approaches of targeting viral ncRNA in HIV, HCV, SARS CoV, and influenza A will provide a basis for the future exploration of RNA targets for therapeutic intervention in other viral pathogens which create urgent, unmet medical needs. Viruses for which targeting ncRNA components in the genome or transcripts may be promising include insect-borne flaviviruses (Dengue, Zika, and West Nile) and filoviruses (Ebola and Marburg). WIREs RNA 2016, 7:726-743. doi: 10.1002/wrna.1373 For further resources related to this article, please visit the WIREs website. © 2016 Wiley Periodicals, Inc.
Towards the development of a triple SMA actuated vertical tube
NASA Astrophysics Data System (ADS)
Karimi, Saeed; Konh, Bardia; Seidi, Ebrahim
2018-03-01
In this work an active vertically hung tube has been designed, fabricated and tested. The active tube was made of three separate 3D printed parts assembled and glued together. Shape Memory Alloy (SMA) wires were embedded as actuators in the body of the tube to privilege from their robust actuation and high energy density. Three SMA wires were trained and installed evenly on the exterior peripheral side of the tubes to realize motion in multiple directions. A deadweight was hung to one end of the tube to exert a certain amount of pre-stress on actuators. This design offers a restricted actuation because the two wires on the opposite side always resist the intended deflection. Hence, for a proper actuation, each wire was stressed to a certain level to exhibit either expansion or contraction upon demand. This amount of stress was selected based on rigorous experimental data. Power supply units were integrated and linked to a python program to control the amount of power passed through each SMA wire. The active tube was tested, and its movement was captured via a camera and analyzed by ImageJ software for the two cases free of stress and with an applied external load. The electrical resistance of the each SMA wire was measured and used for controlling the tube's deflection in each direction. This work demonstrated the feasibility of using three evenly distributed SMA wires on a tube to create motion in 3D direction.
Multiple-layer printed-wiring trace connector
NASA Technical Reports Server (NTRS)
Pizzeck, D. E.
1977-01-01
Nickel-plated spring-steel foil connector is hollow pin, with lengthwise slit, that is inserted into improperly plated-through holes. Edges of connector make positive contact with copper pads within hole.
Reduced cost alternatives to premise wiring using ATM and microcellular technologies
NASA Technical Reports Server (NTRS)
Gejji, Raghvendra R.
1993-01-01
The cost of premises wiring keeps increasing due to personnel moves, new equipment, capacity upgrades etc. It would be desirable to have a wireless interface from the workstations to the fixed network, so as to minimize the wiring changes needed. New technologies such as microcellular personal communication systems are promising to bring down the cost of wireless communication. Another promising technology is Code Division Multiple Access (CDMA), which could dramatically increase the bandwidth available for wireless connections. In addition, Asynchronous Transfer Mode (ATM) technology is emerging as a technique for integrated management of voice, data, and video traffic on a single network. The focus of this investigation will be to assess the future utility of these new technologies for reducing the premise wiring cost at KSC. One of the issues to be studied is the cost comparison of 'old' versus 'new,' especially as time and technology progress. An additional issue for closer study is a feasible time-line for progress in technological capability.
Beyer, Edward T.
1976-01-06
The present invention relates to switches and switch actuating devices to be operated for purposes of arming a bomb or other missile as it is dropped or released from an aircraft. The particular bomb or missile in which this invention is applied is one in which there is a plurality of circuits which are to be armed by the closing of switches upon dropping or releasing of the bomb. The operation of the switches to closed position is normally accomplished by means of a pull-out wire; that is, a wire which is withdrawn from the bomb or missile at the time of release of the bomb, one end of the wire being attached to the aircraft. The conditions to be met are that the arming switches must be positively and surely maintained in open position until the bomb is released and the arming action is effected. The action of the pull-out wire in achieving the arming action must be sure and positive with minimum danger of malfunctioning, jamming or binding.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adams, C.; et al.
We describe the concept and procedure of drifted-charge extraction developed in the MicroBooNE experiment, a single-phase liquid argon time projection chamber (LArTPC). This technique converts the raw digitized TPC waveform to the number of ionization electrons passing through a wire plane at a given time. A robust recovery of the number of ionization electrons from both induction and collection anode wire planes will augment the 3D reconstruction, and is particularly important for tomographic reconstruction algorithms. A number of building blocks of the overall procedure are described. The performance of the signal processing is quantitatively evaluated by comparing extracted charge withmore » the true charge through a detailed TPC detector simulation taking into account position-dependent induced current inside a single wire region and across multiple wires. Some areas for further improvement of the performance of the charge extraction procedure are also discussed.« less
Charged particle tracking through electrostatic wire meshes using the finite element method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Devlin, L. J.; Karamyshev, O.; Welsch, C. P., E-mail: carsten.welsch@cockcroft.ac.uk
Wire meshes are used across many disciplines to accelerate and focus charged particles, however, analytical solutions are non-exact and few codes exist which simulate the exact fields around a mesh with physical sizes. A tracking code based in Matlab-Simulink using field maps generated using finite element software has been developed which tracks electrons or ions through electrostatic wire meshes. The fields around such a geometry are presented as an analytical expression using several basic assumptions, however, it is apparent that computational calculations are required to obtain realistic values of electric potential and fields, particularly when multiple wire meshes are deployed.more » The tracking code is flexible in that any quantitatively describable particle distribution can be used for both electrons and ions as well as other benefits such as ease of export to other programs for analysis. The code is made freely available and physical examples are highlighted where this code could be beneficial for different applications.« less
Mechanical evaluation of quad-helix appliance made of low-nickel stainless steel wire.
dos Santos, Rogério Lacerda; Pithon, Matheus Melo
2013-01-01
The objective of this study was to test the hypothesis that there is no difference between stainless steel and low-nickel stainless steel wires as regards mechanical behavior. Force, resilience, and elastic modulus produced by Quad-helix appliances made of 0.032-inch and 0.036-inch wires were evaluated. Sixty Quad-helix appliances were made, thirty for each type of alloy, being fifteen for each wire thickness, 0.032-in and 0.036-in. All the archwires were submitted to mechanical compression test using an EMIC DL-10000 machine simulating activations of 4, 6, 9, and 12 mm. Analysis of variance (ANOVA) with multiple comparisons and Tukey's test were used (p < 0.05) to assess force, resilience, and elastic modulus. Statistically significant difference in the forces generated, resilience and elastic modulus were found between the 0.032-in and 0.036-in thicknesses (p < 0.05). Appliances made of low-nickel stainless steel alloy had force, resilience, and elastic modulus similar to those made of stainless steel alloy.
Electron transport in high aspect ratio semiconductor nanowires and metal-semiconductor interfaces
NASA Astrophysics Data System (ADS)
Sun, Zhuting
We are facing variability problems for modern semiconductor transistors due to the fact that the performances of nominally identical devices in the scale of 10 100 nm could be dramatically different attributed to the small manufacturing variations. Different doping strategies give statistical variations in the number of dopant atom density ND in the channel. The material size gives variations in wire diameter dW. And the immediate environment of the material leads to an additional level of variability. E.g. vacuum-semiconductor interface causes variations in surface state density Ds, metal-semiconductor interface causes variations in Schottky barrier and dielectric semiconductor interface induces dielectric confinement at small scales. To approach these variability problems, I choose Si-doped GaAs nanowires as an example. I investigate transport in Si-doped GaAs nanowire (NW) samples contacted by lithographically patterned Gold-Titanium films as function of temperature T. I find a drastically different temperature dependence between the wire resistance RW, which is relatively weak, and the zero bias resistance RC, which is strong. I show that the data are consistent with a model based on a sharp donor energy level slightly above the bottom of the semiconductor conduction band and develop a simple method for using transport measurements for estimates of the doping density after nanowire growth. I discuss the predictions of effective free carrier density n eff as function of the surface state density Ds and wire size dW. I also describe a correction to the widely used model of Schottky contacts that improves thermodynamic consistency of the Schottky tunnel barrier profile and show that the original theory may underestimate the barrier conductance under certain conditions. I also provide analytical calculations for shallow silicon dopant energy in GaAs crystals, and find the presence of dielectrics (dielectric screening) and free carriers (Coulomb screening) cause a reduction of ionization energy and shift the donor energy level ED upward, accompanying conduction band EC shift downward due to band gap narrowing for doped semiconductor material. The theoretical results are in a reasonable agreement with previous experimental data. I also find that when the material reduces to nanoscale, dielectric confinement and surface depletion compete with both Coulomb screening and dielectric screening that shift the donor level ED down towards the band gap. The calculation should be appropriate for all types of semiconductors and dopant species.
A Multiple-range Self-balancing Thermocouple Potentiometer
NASA Technical Reports Server (NTRS)
Warshawsky, I; Estrin, M
1951-01-01
A multiple-range potentiometer circuit is described that provides automatic measurement of temperatures or temperature differences with any one of several thermocouple-material pairs. Techniques of automatic reference junction compensation, span adjustment, and zero suppression are described that permit rapid selection of range and wire material, without the necessity for restandardization, by setting of two external tap switches.
Environmental Influence of Gravity and Pressure on Arc Tracking of Insulated Wires Investigated
NASA Technical Reports Server (NTRS)
2005-01-01
Momentary short-circuit arcs between a defective polyimide-insulated wire and another conductor may thermally char (pyrolize) the insulating material. The charred polyimide, being conductive, can sustain the short-circuit arc, which may propagate along the wire through continuous pyrolization of the polyimide insulation (arc tracking). If the arcing wire is part of a multiple-wire bundle, the polyimide insulation of other wires within the bundle may become thermally charred and start arc tracking also (flash over). Such arc tracking can lead to complete failure of an entire wire bundle, causing other critical spacecraft or aircraft failures. Unfortunately, all tested candidate wire insulations for aerospace vehicles were susceptible to arc tracking. Therefore, a test procedure was designed at the NASA Lewis Research Center to select the insulation type least susceptible to arc tracking. This test procedure addresses the following three areas of concern: (1) probability of initiation, (2) probability of reinitiation (restrike), and (3) extent of arc tracking damage (propagation rate). Item 2 (restrike probability) is an issue if power can be terminated from and reapplied to the arcing wire (by a switch, fuse, or resettable circuit breaker). The degree of damage from an arcing event (item 3) refers to how easily the arc chars nearby insulation and propagates along the wire pair. Ease of nearby insulation charring can be determined by measuring the rate of arc propagation. Insulation that chars easily will propagate the arc faster than insulation that does not char very easily. A popular polyimide insulated wire for aerospace vehicles, MIL-W-81381, was tested to determine a degree of damage from an arcing event (item 3) in the following three environments: (1) microgravity with air at 1-atm pressure, (2) 1g with air at 1 atm, and (3) 1g within a 10^-6 Torr vacuum. The microgravity 1-atm air was the harshest environment, with respect to the rate of damage of arc tracking, for the 20 AWG (American Wiring Gauge) MIL-W-81381 wire insulation type . The vacuum environment resulted in the least damage. Further testing is planned to determine if the environmental results are consistent between insulation types and to evaluate the other two parameters associated with arc tracking susceptibility.
Wire Array Solar Cells: Fabrication and Photoelectrochemical Studies
NASA Astrophysics Data System (ADS)
Spurgeon, Joshua Michael
Despite demand for clean energy to reduce our addiction to fossil fuels, the price of these technologies relative to oil and coal has prevented their widespread implementation. Solar energy has enormous potential as a carbon-free resource but is several times the cost of coal-produced electricity, largely because photovoltaics of practical efficiency require high-quality, pure semiconductor materials. To produce current in a planar junction solar cell, an electron or hole generated deep within the material must travel all the way to the junction without recombining. Radial junction, wire array solar cells, however, have the potential to decouple the directions of light absorption and charge-carrier collection so that a semiconductor with a minority-carrier diffusion length shorter than its absorption depth (i.e., a lower quality, potentially cheaper material) can effectively produce current. The axial dimension of the wires is long enough for sufficient optical absorption while the charge-carriers are collected along the shorter radial dimension in a massively parallel array. This thesis explores the wire array solar cell design by developing potentially low-cost fabrication methods and investigating the energy-conversion properties of the arrays in photoelectrochemical cells. The concept was initially investigated with Cd(Se, Te) rod arrays; however, Si was the primary focus of wire array research because its semiconductor properties make low-quality Si an ideal candidate for improvement in a radial geometry. Fabrication routes for Si wire arrays were explored, including the vapor-liquid-solid growth of wires using SiCl4. Uniform, vertically aligned Si wires were demonstrated in a process that permits control of the wire radius, length, and spacing. A technique was developed to transfer these wire arrays into a low-cost, flexible polymer film, and grow multiple subsequent arrays using a single Si(111) substrate. Photoelectrochemical measurements on Si wire array/polymer composite films showed that their energy-conversion properties were comparable to those of an array attached to the growth substrate. High quantum efficiencies were observed relative to the packing density of the wires, particularly with illumination at high angles of incidence. The results indicate that an inexpensive, solid-state Si wire array solar cell is possible, and a plan is presented to develop one.
Pressure drop and He II flow through fine mesh screens
NASA Astrophysics Data System (ADS)
Maddocks, J. R.; van Sciver, S. W.
1989-05-01
Fluid acquisition systems for He II transfer devices will utilize gallery arms to ensure that the fluid encounters the pump inlet. In near term experiments such as Superfluid Helium on Orbit Transfer (SHOOT), the preferred configuration consists of several rectangular channels which have one side made from a Dutch weave stainless steel screen having 325 x 2300 wires per inch. The effective pore diameter for this screen is about 5 microns. The present paper reports on measurements of pressure drop across a screen when it is subjected to a flow of liquid helium. The experiment measures the time rate of change of the level in two different helium reservoirs connected by a screen-blocked channel. Results with normal helium are compared with predictions based on the Armour-Cannon (1968) equations. The He II data show considerable deviation from the classical result. A discussion of the He II pressure drop results in terms of two fluid hydrodynamics is included.
Pressure drop and He II flow through fine mesh screens
NASA Technical Reports Server (NTRS)
Maddocks, J. R.; Van Sciver, S. W.
1989-01-01
Fluid acquisition systems for He II transfer devices will utilize gallery arms to ensure that the fluid encounters the pump inlet. In near term experiments such as Superfluid Helium on Orbit Transfer (SHOOT), the preferred configuration consists of several rectangular channels which have one side made from a Dutch weave stainless steel screen having 325 x 2300 wires per inch. The effective pore diameter for this screen is about 5 microns. The present paper reports on measurements of pressure drop across a screen when it is subjected to a flow of liquid helium. The experiment measures the time rate of change of the level in two different helium reservoirs connected by a screen-blocked channel. Results with normal helium are compared with predictions based on the Armour-Cannon (1968) equations. The He II data show considerable deviation from the classical result. A discussion of the He II pressure drop results in terms of two fluid hydrodynamics is included.
Microwave Power Combiners for Signals of Arbitrary Amplitude
NASA Technical Reports Server (NTRS)
Conroy, Bruce; Hoppe, Daniel
2009-01-01
Schemes for combining power from coherent microwave sources of arbitrary (unequal or equal) amplitude have been proposed. Most prior microwave-power-combining schemes are limited to sources of equal amplitude. The basic principle of the schemes now proposed is to use quasi-optical components to manipulate the polarizations and phases of two arbitrary-amplitude input signals in such a way as to combine them into one output signal having a specified, fixed polarization. To combine power from more than two sources, one could use multiple powercombining stages based on this principle, feeding the outputs of lower-power stages as inputs to higher-power stages. Quasi-optical components suitable for implementing these schemes include grids of parallel wires, vane polarizers, and a variety of waveguide structures. For the sake of brevity, the remainder of this article illustrates the basic principle by focusing on one scheme in which a wire grid and two vane polarizers would be used. Wire grids are the key quasi-optical elements in many prior equal-power combiners. In somewhat oversimplified terms, a wire grid reflects an incident beam having an electric field parallel to the wires and passes an incident beam having an electric field perpendicular to the wires. In a typical prior equal-power combining scheme, one provides for two properly phased, equal-amplitude signals having mutually perpendicular linear polarizations to impinge from two mutually perpendicular directions on a wire grid in a plane oriented at an angle of 45 with respect to both beam axes. The wires in the grid are oriented to pass one of the incident beams straight through onto the output path and to reflect the other incident beam onto the output path along with the first-mentioned beam.
STEREOMATRIX 3-D display system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whiteside, Stephen Earl
1973-08-01
STEREOMATRIX is a large-screen interactive 3-D laser display system which presents computer-generated wire figures stereoscopically. The presented image can be rotated, translated, and scaled by the system user and the perspective of the image is changed according to the position of the user. A cursor may be positioned in three dimensions to identify points and allows communication with the computer.
Germination and field survival of white-topped pitcher plant seeds
Kristina Connor; Hilliard Gibbs
2012-01-01
A study was initiated to determine longevity of white-topped pitcher plant (Sarracenia leucophylla, Raf.) seeds in the field and in cold storage. Thirty seed pods were harvested in August 2009 from plants located in Alabama 38 miles from the Gulf Coast. Of the 10,000+ seeds extracted from the pods, some were buried outside in screen-wire bags and...
NASA Astrophysics Data System (ADS)
Bigu, J.; Raz, R.
1985-01-01
A solid-state alpha dosimeter has been designed and tested suitable for personal and environmental radon/thoron monitoring. The dosimeter basically consists of an electrostatic collector and an alpha-particle counting system with spectroscopy capabilities. The sensitive volume (˜20 cm3) of the electrostatic collector consists of a cylindrically shaped metal wire screen and a diffused-junction silicon alpha-detector covered with a thin aluminized Mylar sheet. A dc voltage (˜500 V) is applied between the wire screen and the Mylar sheet, with the latter held at negative potential relative to the former. Data can be retrieved during or after sampling by means of a microcomputer (Epson HX20) via a RS-232 communication interface unit. The dosimeter has been calibrated in a large (26 m3) radon/thoron test facility. A linear relationship was found between the dosimeter's alpha-count and both radon gas concentration and radon daughter working level. The dosimeter is mounted on top of an ordinary miner's cap lamp battery and is ideally suited for personal monitoring in underground uranium mines and other working areas. The dosimeter presented here is a considerably improved version of an earlier prototype.
Predictors of temporary epicardial pacing wires use after valve surgery
2014-01-01
Background Although temporary cardiac pacing is infrequently needed, temporary epicardial pacing wires are routinely inserted after valve surgery. As they are associated with infrequent, but life threatening complications, and the decreased need for postoperative pacing in a group of low risk patients; this study aims to identify the predictors of temporary cardiac pacing after valve surgery. Methods A retrospective analysis of data collected prospectively on 400 consecutive valve surgery patients between May 2002 and December 2012 was performed. Patients were grouped according to avoidance or insertion of temporary pacing wires, and were further subdivided according to temporary cardiac pacing need. Multiple logistic regression was used to determine the predictors of temporary cardiac pacing. Results 170 (42.5%) patients did not have insertion of temporary pacing wires and none of them needed temporary pacing. 230 (57.5%) patients had insertion of temporary pacing wires and among these, only 55 (23.9%) required temporary pacing who were compared with the remaining 175 (76.1%) patients in the main analysis. The determinants of temporary cardiac pacing (adjusted odds ratios; 95% confidence interval) were as follows: increased age (1.1; 1.1, 1.3, p = 0.002), New York Heart Association class III- IV (5.6; 1.6, 20.2, p = 0.008) , pulmonary artery pressure ≥ 50 mmHg (22.0; 3.4, 142.7, p = 0.01), digoxin use (8.0; 1.3, 48.8, p = 0.024), multiple valve surgery (13.5; 1.5, 124.0, p = 0.021), aorta cross clamp time ≥ 60 minutes (7.8; 1.6, 37.2, p = 0.010), and valve annulus calcification (7.9; 2.0, 31.7, p = 0.003). Conclusion Although limited by sample size, the present results suggest that routine use of temporary epicardial pacing wires after valve surgery is only necessary for high risk patients. Preoperative identification and aggressive management of predictors of temporary cardiac pacing and the possible modulation of intraoperative techniques can decrease the need of temporary cardiac pacing. Prospective randomized controlled studies on a larger number of patients are necessary to draw solid conclusions regarding the selective use of temporary epicardial pacing wires in valve surgery. PMID:24521215
The constant current loop: A new paradigm for resistance signal conditioning
NASA Astrophysics Data System (ADS)
Anderson, Karl F.
1994-02-01
A practical single constant current loop circuit for the signal conditioning of variable-resistance transducers has been synthesized, analyzed, and demonstrated. The strain gage and the resistance temperature detector are examples of variable-resistance sensors. Lead wires connect variable-resistance sensors to remotely located signal-conditioning hardware. The presence of lead wires in the conventional Wheatstone bridge signal-conditioning circuit introduces undesired effects that reduce the quality of the data from the remote sensors. A practical approach is presented for suppressing essentially all lead wire resistance effects while indicating only the change in resistance value. Theoretical predictions supported by laboratory testing confirm the following features of the approach: (1) dc response; (2) the electrical output is unaffected by extremely large variation in the resistance of any or all lead wires; (3) the electrical output remains zero for no change in gage resistance; (4) the electrical output is inherently linear with respect to gage resistance change; (5) the sensitivity is double that of a Wheatstone bridge circuit; and (6) the same excitation wires can serve multiple independent gages. An adaptation of current loop circuit is presented that simultaneously provides an output signal voltage directly proportional to transducer resistance change and provides temperature information that is unaffected by transducer and lead wire resistance variations. These innovations are the subject of NASA patent applications.
The constant current loop: A new paradigm for resistance signal conditioning
NASA Astrophysics Data System (ADS)
Anderson, Karl F.
1992-10-01
A practical single constant current loop circuit for the signal conditioning of variable resistance transducers has been synthesized, analyzed, and demonstrated. The strain gage and the resistance temperature device are examples of variable resistance sensors. Lead wires connect variable resistance sensors to remotely located signal conditioning hardware. The presence of lead wires in the conventional Wheatstone bridge signal conditioning circuit introduces undesired effects that reduce the quality of the data from the remote sensors. A practical approach is presented for suppressing essentially all lead wire resistance effects while indicating only the change in resistance value. Theoretical predictions supported by laboratory testing confirm the following features of the approach: (1) dc response; (2) the electrical output is unaffected by extremely large variations in the resistance of any or all lead wires; (3) the electrical output remains zero for no change in gage resistance; (4) the electrical output is inherently linear with respect to gage resistance change; (5) the sensitivity is double that of a Wheatstone bridge circuit; and (6) the same excitation wires can serve multiple independent gages. An adaptation of current loop circuit is presented that simultaneously provides an output signal voltage directly proportional to transducer resistance change and provides temperature information that is unaffected by transducer and lead wire resistance variations. These innovations are the subject of NASA patent applications.
The constant current loop: A new paradigm for resistance signal conditioning
NASA Astrophysics Data System (ADS)
Anderson, Karl F.
A practical, single, constant-current loop circuit for the signal conditioning of variable-resistance transducers was synthesized, analyzed, and demonstrated. The strain gage and the resistance temperature device are examples of variable-resistance sensors. Lead wires connect variable-resistance sensors to remotely located signal-conditioning hardware. The presence of lead wires in the conventional Wheatstone bridge signal-conditioning circuit introduces undesired effects that reduce the quality of the data from the remote sensors. A practical approach is presented for suppressing essentially all lead wire resistance effects while indicating only the change in resistance value. Theoretical predictions supported by laboratory testing confirm the following features of the approach: (1) the dc response; (2) the electrical output is unaffected by extremely large variations in the resistance of any or all lead wires; (3) the electrical output remains zero for no change in gage resistance; (4) the electrical output is inherently linear with respect to gage resistance change; (5) the sensitivity is double that of a Wheatstone bridge circuit; and (6) the same excitation and sense wires can serve multiple independent gages. An adaptation of the current loop circuit is presented that simultaneously provides an output signal voltage directly proportional to transducer resistance change and provides temperature information that is unaffected by transducer and lead wire resistance variations. These innovations are the subject of NASA patent applications.
The constant current loop: A new paradigm for resistance signal conditioning
NASA Technical Reports Server (NTRS)
Anderson, Karl F.
1994-01-01
A practical single constant current loop circuit for the signal conditioning of variable-resistance transducers has been synthesized, analyzed, and demonstrated. The strain gage and the resistance temperature detector are examples of variable-resistance sensors. Lead wires connect variable-resistance sensors to remotely located signal-conditioning hardware. The presence of lead wires in the conventional Wheatstone bridge signal-conditioning circuit introduces undesired effects that reduce the quality of the data from the remote sensors. A practical approach is presented for suppressing essentially all lead wire resistance effects while indicating only the change in resistance value. Theoretical predictions supported by laboratory testing confirm the following features of the approach: (1) dc response; (2) the electrical output is unaffected by extremely large variation in the resistance of any or all lead wires; (3) the electrical output remains zero for no change in gage resistance; (4) the electrical output is inherently linear with respect to gage resistance change; (5) the sensitivity is double that of a Wheatstone bridge circuit; and (6) the same excitation wires can serve multiple independent gages. An adaptation of current loop circuit is presented that simultaneously provides an output signal voltage directly proportional to transducer resistance change and provides temperature information that is unaffected by transducer and lead wire resistance variations. These innovations are the subject of NASA patent applications.
The constant current loop: A new paradigm for resistance signal conditioning
NASA Technical Reports Server (NTRS)
Anderson, Karl F.
1993-01-01
A practical, single, constant-current loop circuit for the signal conditioning of variable-resistance transducers was synthesized, analyzed, and demonstrated. The strain gage and the resistance temperature device are examples of variable-resistance sensors. Lead wires connect variable-resistance sensors to remotely located signal-conditioning hardware. The presence of lead wires in the conventional Wheatstone bridge signal-conditioning circuit introduces undesired effects that reduce the quality of the data from the remote sensors. A practical approach is presented for suppressing essentially all lead wire resistance effects while indicating only the change in resistance value. Theoretical predictions supported by laboratory testing confirm the following features of the approach: (1) the dc response; (2) the electrical output is unaffected by extremely large variations in the resistance of any or all lead wires; (3) the electrical output remains zero for no change in gage resistance; (4) the electrical output is inherently linear with respect to gage resistance change; (5) the sensitivity is double that of a Wheatstone bridge circuit; and (6) the same excitation and sense wires can serve multiple independent gages. An adaptation of the current loop circuit is presented that simultaneously provides an output signal voltage directly proportional to transducer resistance change and provides temperature information that is unaffected by transducer and lead wire resistance variations. These innovations are the subject of NASA patent applications.
Gibs, Jacob; Brown, G. Allan; Turner, Kenneth S.; MacLeod, Cecilia L.; Jelinski, James; Koehnlein, Susan A.
1993-01-01
Because a water sample collected from a well is an integration of water from different depths along the well screen, measured concentrations can be biased if analyte concentrations are not uniform along the length of the well screen. The resulting concentration in the sample, therefore, is a function of variations in well-screen inflow rate and analyte concentration with depth. A multiport sampler with seven short screened intervals was designed and used to investigate small-scale vertical variations in water chemistry and aquifer hydraulic conductivity in ground water contaminated by leaded gasoline at Galloway Township, Atlantic County, New Jersey. The multiport samplers were used to collect independent samples from seven intervals within the screened zone that were flow-rate weighted and integrated to simulate a 5-foot-long, 2.375-inch- outside-diameter conventional wire-wound screen. The integration of the results of analyses of samples collected from two multiport samplers showed that a conventional 5-foot-long well screen would integrate contaminant concentrations over its length and resulted in an apparent contaminant concentration that was a little as 28 percent of the maximum concentration observed in the multiport sampler.
Manchester Coding Option for SpaceWire: Providing Choices for System Level Design
NASA Technical Reports Server (NTRS)
Rakow, Glenn; Kisin, Alex
2014-01-01
This paper proposes an optional coding scheme for SpaceWire in lieu of the current Data Strobe scheme for three reasons. First reason is to provide a straightforward method for electrical isolation of the interface; secondly to provide ability to reduce the mass and bend radius of the SpaceWire cable; and thirdly to provide a means for a common physical layer over which multiple spacecraft onboard data link protocols could operate for a wide range of data rates. The intent is to accomplish these goals without significant change to existing SpaceWire design investments. The ability to optionally use Manchester coding in place of the current Data Strobe coding provides the ability to DC balanced the signal transitions unlike the SpaceWire Data Strobe coding; and therefore the ability to isolate the electrical interface without concern. Additionally, because the Manchester code has the clock and data encoded on the same signal, the number of wires of the existing SpaceWire cable could be optionally reduced by 50. This reduction could be an important consideration for many users of SpaceWire as indicated by the already existing effort underway by the SpaceWire working group to reduce the cable mass and bend radius by elimination of shields. However, reducing the signal count by half would provide even greater gains. It is proposed to restrict the data rate for the optional Manchester coding to a fixed data rate of 10 Megabits per second (Mbps) in order to make the necessary changes simple and still able to run in current radiation tolerant Field Programmable Gate Arrays (FPGAs). Even with this constraint, 10 Mbps will meet many applications where SpaceWire is used. These include command and control applications and many instruments applications with have moderate data rate. For most NASA flight implementations, SpaceWire designs are in rad-tolerant FPGAs, and the desire to preserve the heritage design investment is important for cost and risk considerations. The Manchester coding option can be accommodated in existing designs with only changes to the FPGA.
High resolution structural characterisation of laser-induced defect clusters inside diamond
NASA Astrophysics Data System (ADS)
Salter, Patrick S.; Booth, Martin J.; Courvoisier, Arnaud; Moran, David A. J.; MacLaren, Donald A.
2017-08-01
Laser writing with ultrashort pulses provides a potential route for the manufacture of three-dimensional wires, waveguides, and defects within diamond. We present a transmission electron microscopy study of the intrinsic structure of the laser modifications and reveal a complex distribution of defects. Electron energy loss spectroscopy indicates that the majority of the irradiated region remains as sp3 bonded diamond. Electrically conductive paths are attributed to the formation of multiple nano-scale, sp2-bonded graphitic wires and a network of strain-relieving micro-cracks.
Manipulation of biological cells using a microelectromagnet matrix
NASA Astrophysics Data System (ADS)
Lee, H.; Purdon, A. M.; Westervelt, R. M.
2004-08-01
Noninvasive manipulation of biological cells inside a microfluidic channel was demonstrated using a microelectromagnet matrix. The matrix consists of two layers of straight Au wires, aligned perpendicular to each other, that are covered by insulating layers. By adjusting the current in each independent wire, the microelectromagnet matrix can create versatile magnetic field patterns to control the motion of individual cells in fluid. Single or multiple yeast cells attached to magnetic beads were trapped, continuously moved and rotated, and a viable cell was separated from nonviable cells for cell sorting.
Multiple Differential-Amplifier MMICs Embedded in Waveguides
NASA Technical Reports Server (NTRS)
Kangaslahti, Pekka; Schlecht, Erich
2010-01-01
Compact amplifier assemblies of a type now being developed for operation at frequencies of hundreds of gigahertz comprise multiple amplifier units in parallel arrangements to increase power and/or cascade arrangements to increase gains. Each amplifier unit is a monolithic microwave integrated circuit (MMIC) implementation of a pair of amplifiers in differential (in contradistinction to single-ended) configuration. Heretofore, in cascading amplifiers to increase gain, it has been common practice to interconnect the amplifiers by use of wires and/or thin films on substrates. This practice has not yielded satisfactory results at frequencies greater than 200 Hz, in each case, for either or both of two reasons: Wire bonds introduce large discontinuities. Because the interconnections are typically tens of wavelengths long, any impedance mismatches give rise to ripples in the gain-vs.-frequency response, which degrade the performance of the cascade.
Distributing Data from Desktop to Hand-Held Computers
NASA Technical Reports Server (NTRS)
Elmore, Jason L.
2005-01-01
A system of server and client software formats and redistributes data from commercially available desktop to commercially available hand-held computers via both wired and wireless networks. This software is an inexpensive means of enabling engineers and technicians to gain access to current sensor data while working in locations in which such data would otherwise be inaccessible. The sensor data are first gathered by a data-acquisition server computer, then transmitted via a wired network to a data-distribution computer that executes the server portion of the present software. Data in all sensor channels -- both raw sensor outputs in millivolt units and results of conversion to engineering units -- are made available for distribution. Selected subsets of the data are transmitted to each hand-held computer via the wired and then a wireless network. The selection of the subsets and the choice of the sequences and formats for displaying the data is made by means of a user interface generated by the client portion of the software. The data displayed on the screens of hand-held units can be updated at rates from 1 to
Chen, Yuhan; Wang, Shengjun; Hilgetag, Claus C.; Zhou, Changsong
2013-01-01
The formation of the complex network architecture of neural systems is subject to multiple structural and functional constraints. Two obvious but apparently contradictory constraints are low wiring cost and high processing efficiency, characterized by short overall wiring length and a small average number of processing steps, respectively. Growing evidence shows that neural networks are results from a trade-off between physical cost and functional value of the topology. However, the relationship between these competing constraints and complex topology is not well understood quantitatively. We explored this relationship systematically by reconstructing two known neural networks, Macaque cortical connectivity and C. elegans neuronal connections, from combinatory optimization of wiring cost and processing efficiency constraints, using a control parameter , and comparing the reconstructed networks to the real networks. We found that in both neural systems, the reconstructed networks derived from the two constraints can reveal some important relations between the spatial layout of nodes and the topological connectivity, and match several properties of the real networks. The reconstructed and real networks had a similar modular organization in a broad range of , resulting from spatial clustering of network nodes. Hubs emerged due to the competition of the two constraints, and their positions were close to, and partly coincided, with the real hubs in a range of values. The degree of nodes was correlated with the density of nodes in their spatial neighborhood in both reconstructed and real networks. Generally, the rebuilt network matched a significant portion of real links, especially short-distant ones. These findings provide clear evidence to support the hypothesis of trade-off between multiple constraints on brain networks. The two constraints of wiring cost and processing efficiency, however, cannot explain all salient features in the real networks. The discrepancy suggests that there are further relevant factors that are not yet captured here. PMID:23505352
Spooled packaging of shape memory alloy actuators
NASA Astrophysics Data System (ADS)
Redmond, John A.
A vast cross-section of transportation, manufacturing, consumer product, and medical technologies rely heavily on actuation. Accordingly, progress in these industries is often strongly coupled to the advancement of actuation technologies. As the field of actuation continues to evolve, smart materials show significant promise for satisfying the growing needs of industry. In particular, shape memory alloy (SMA) wire actuators present an opportunity for low-cost, high performance actuation, but until now, they have been limited or restricted from use in many otherwise suitable applications by the difficulty in packaging the SMA wires within tight or unusually shaped form constraints. To address this packaging problem, SMA wires can be spool-packaged by wrapping around mandrels to make the actuator more compact or by redirecting around multiple mandrels to customize SMA wire pathways to unusual form factors. The goal of this dissertation is to develop the scientific knowledge base for spooled packaging of low-cost SMA wire actuators that enables high, predictable performance within compact, customizable form factors. In developing the scientific knowledge base, this dissertation defines a systematic general representation of single and multiple mandrel spool-packaged SMA actuators and provides tools for their analysis, understanding, and synthesis. A quasi-static analytical model distills the underlying mechanics down to the three effects of friction, bending, and binding, which enables prediction of the behavior of generic spool-packaged SMA actuators with specifiable geometric, loading, frictional, and SMA material parameters. An extensive experimental and simulation-based parameter study establishes the necessary understanding of how primary design tradeoffs between performance, packaging, and cost are governed by the underlying mechanics of spooled actuators. A design methodology outlines a systematic approach to synthesizing high performance SMA wire actuators with mitigated material, power, and packaging costs and compact, customizable form factors. By examining the multi-faceted connections between performance, packaging, and cost, this dissertation builds a knowledge base that goes beyond implementing SMA actuators for particular applications. Rather, it provides a well-developed strategy for realizing the advantages of SMA actuation for a broadened range of applications, thereby enabling opportunities for new functionality and capabilities in industry.
NASA/BAE SYSTEMS SpaceWire Effort
NASA Technical Reports Server (NTRS)
Rakow, Glenn Parker; Schnurr, Richard G.; Kapcio, Paul
2003-01-01
This paper discusses the state of the NASA and BAE SYSTEMS developments of SpaceWire. NASA has developed intellectual property that implements SpaceWire in Register Transfer Level (RTL) VHDL for a SpaceWire link and router. This design has been extensively verified using directed tests from the SpaceWire Standard and design specification, as well as being randomly tested to flush out hard to find bugs in the code. The high level features of the design will be discussed, including the support for multiple time code masters, which will be useful for the James Webb Space Telescope electrical architecture. This design is now ready to be targeted to FPGA's and ASICs. Target utilization and performance information will be presented for Spaceflight worthy FPGA's and a discussion of the ASIC implementations will be addressed. In particular, the BAE SYSTEMS ASIC will be highlighted which will be implemented on their .25micron rad-hard line. The chip will implement a 4-port router with the ability to tie chips together to make larger routers without external glue logic. This part will have integrated LVDS drivers/receivers, include a PLL and include skew control logic. It will be targeted to run at greater than 300 MHz and include the implementation for the proposed SpaceWire transport layer. The need to provide a reliable transport mechanism for SpaceWire has been identified by both NASA And ESA, who are attempting to define a transport layer standard that utilizes a low overhead, low latency connection oriented approach that works end-to-end. This layer needs to be implemented in hardware to prevent bottlenecks.
Kaur, Sandeep; Harjai, Kusum; Chhibber, Sanjay
2014-01-01
Background Infections of bone and joint tissues following arthroplasty surgeries remain a major challenge in orthopaedic settings. Methicillin resistant Staphylococcus aureus (MRSA) is recognised as an established pathogen in such infections. Combination therapy using linezolid and bacteriophage impregnated in biopolymer was investigated in the present study as an alternative strategy to prevent MRSA colonisation on the orthopaedic implant surface. Methodology Coating of stainless steel orthopaedic grade K-wires was achieved using hydroxypropylmethlycellulose (HPMC) mixed with phage alone, linezolid alone and phage and linezolid together. The potential of these agents to inhibit adhesion of S.aureus (MRSA) 43300 on K-wires was assessed. Coated and naked wires were analysed by scanning electron microscopy (SEM) and fluorescent staining. Result Significant reduction in bacterial adhesion was achieved on phage/linezolid wires in comparison to naked as well as HPMC coated wires. However, maximum reduction in bacterial adherence (∼4 log cycles) was observed on the wires coated with phage-linezolid combination. The frequency of emergence of resistant mutants was also negligible in presence of both the agents. Conclusion This study provides evidence to confirm that local delivery system employing linezolid (a potent protein synthesis inhibitor) along with a broad spectrum lytic bacteriophage (capable of self-multiplication) is able to attack the adhered as well as surrounding bacteria present near the implant site. Unlike other antibiotic based therapies, this combination has the potential to significantly restrict the emergence of resistant mutants, thus paving the way for effective treatment of MRSA associated infection of medical implants. PMID:24594764
Hierarchical screening for multiple mental disorders.
Batterham, Philip J; Calear, Alison L; Sunderland, Matthew; Carragher, Natacha; Christensen, Helen; Mackinnon, Andrew J
2013-10-01
There is a need for brief, accurate screening when assessing multiple mental disorders. Two-stage hierarchical screening, consisting of brief pre-screening followed by a battery of disorder-specific scales for those who meet diagnostic criteria, may increase the efficiency of screening without sacrificing precision. This study tested whether more efficient screening could be gained using two-stage hierarchical screening than by administering multiple separate tests. Two Australian adult samples (N=1990) with high rates of psychopathology were recruited using Facebook advertising to examine four methods of hierarchical screening for four mental disorders: major depressive disorder, generalised anxiety disorder, panic disorder and social phobia. Using K6 scores to determine whether full screening was required did not increase screening efficiency. However, pre-screening based on two decision tree approaches or item gating led to considerable reductions in the mean number of items presented per disorder screened, with estimated item reductions of up to 54%. The sensitivity of these hierarchical methods approached 100% relative to the full screening battery. Further testing of the hierarchical screening approach based on clinical criteria and in other samples is warranted. The results demonstrate that a two-phase hierarchical approach to screening multiple mental disorders leads to considerable increases efficiency gains without reducing accuracy. Screening programs should take advantage of prescreeners based on gating items or decision trees to reduce the burden on respondents. © 2013 Elsevier B.V. All rights reserved.
The Work Softening Behavior of Pure Mg Wire during Cold Drawing.
Sun, Liuxia; Bai, Jing; Xue, Feng; Chu, Chenglin; Meng, Jiao
2018-04-13
We performed multiple-pass cold drawing for pure Mg wire which showed excellent formability (~138% accumulative true strain) at room temperature. Different from the continuous work hardening occurring during cold drawing of Mg alloy wires, for pure Mg, an initially rapid increase in hardness and strength was followed by significant work softening and finally reached a steady-state level, approximately 40~45 HV. The work softening can be attributed to the dynamic recovery and recrystallization of pure Mg at room temperature. Meanwhile, an abrupt change in texture component also was detected with the transition from work hardening to softening in the strain range of 28~34%. During the whole drawing, the strongest texture component gradually transformed from as-extruded basal to <10 1 ¯ 0> fiber (~28% accumulative true strain), and then rapidly returned to the weak basal texture.
Thermal Dispersion Within a Porous Medium Near a Solid Wall
NASA Technical Reports Server (NTRS)
Simon, T.; McFadden, G.; Ibrahim, M.
2006-01-01
The regenerator is a key component to Stirling cycle machine efficiency. Typical regenerators are of sintered fine wires or layers of fine-wire screens. Such porous materials are contained within solid-waH casings. Thermal energy exchange between the regenerator and the casing is important to cycle performance for the matrix and casing would not have the same axial temperature profile in an actual machine. Exchange from one to the other may allow shunting of thermal energy, reducing cycle efficiency. In this paper, temperature profiles within the near-wall region of the matrix are measured and thermal energy transport, termed thermal dispersion, is inferred. The data show how the wall affects thermal transport. Transport normal to the mean flow direction is by conduction within the solid and fluid and by advective transport within the matrix. In the near-wall region, both may be interrupted from their normal in-core pattern. Solid conduction paths are broken and scales of advective transport are damped. An equation is presented which describes this change for a wire screen mesh. The near-wall layer typically acts as an insulating layer. This should be considered in design or analysis. Effective thermal conductivity within the core is uniform. In-core transverse thermal effective conductivity values are compared to direct and indirect measurements reported elsewhere and to 3D numerical simulation results, computed previously and reported elsewhere. The 3-D CFD model is composed of six cylinders in cross flow, staggered in arrangement to match the dimensions and porosity of the matrix used in the experiments. The commercial code FLUENT is used to obtain the flow and thermal fields. The thermal dispersion and effective thermal conductivities for the matrix are computed from the results.
Design Modification of Electrophoretic Equipment
NASA Technical Reports Server (NTRS)
Reddick, J. M.; Hirsch, I.
1973-01-01
The improved design of a zone electrophoretic sampler is reported that can be used in mass screening for hemoglobin S, the cause of sickle cell anemia. Considered is a high voltage multicell cellulose acetate device that requires 5 to 6 minutes electrophoresis periods; cells may be activitated individually or simultaneously. A multisample hemoglobin applicator standardizes the amount of sample applied and transfers the homolysate to the electrical wires.
Static Multiple-Pole Homopolar Generator With a Superconducting Screen,
1983-11-03
STANAR193-A OlCFILE GORY 00 FOREIGN TECHNOLOGY DIVISION STATIC MULTIPLE-POLE HOMOPOLAR GENERATOR WITH A SUPERC9ONDUCTING SCREEN by V.P. Kartsev, avld...November 1983 MICROFICHE MJR: FTD-83-C-001336 STATIC %fULTIPLE-POLE HOMOPOLAR GENERATOR WITH A SUPRCONDUCTING SCREEN By: V.P. Kartsev, and I.M. Yegorov...this translation were extracted from the best quality copy available. STATIC MULTIPLE-POLE HOMOPOLAR GENERATOR WITH A SUPERCONDUCTING SCREEN V.P
NASA Astrophysics Data System (ADS)
Darr, S. R.; Camarotti, C. F.; Hartwig, J. W.; Chung, J. N.
2017-01-01
Technologies that enable the storage and transfer of cryogenic propellants in space will be needed for the next generation vehicles that will carry humans to Mars. One of the candidate technologies is the screen channel liquid acquisition device (LAD), which uses a metal woven wire mesh to separate the liquid and vapor phases so that single-phase liquid propellant can be transferred in microgravity. In this work, an experiment is carried out that provides measurements of the velocity and pressure fields in a screen channel LAD. These data are used to validate a new analytical solution of the liquid flow through a screen channel LAD. This hydrodynamic model, which accounts for non-uniform injection through the screen, is compared with the traditional pressure term summation model which assumes a constant, uniform injection velocity. Results show that the new model performs best against the new data and historical data. The velocity measurements inside the screen channel LAD are used to provide a more accurate velocity profile which further improves the new model. The result of this work is a predictive tool that will instill confidence in the design of screen channel LADs for future in-space propulsion systems.
NASA Astrophysics Data System (ADS)
Carter, Rachel; Huhman, Brett; Love, Corey T.; Zenyuk, Iryna V.
2018-03-01
X-ray computed tomography (X-ray CT) across multiple length scales is utilized for the first time to investigate the physical abuse of high C-rate pulsed discharge on cells wired individually and in parallel.. Manufactured lithium iron phosphate cells boasting high rate capability were pulse power tested in both wiring conditions with high discharge currents of 10C for a high number of cycles (up to 1200) until end of life (<80% of initial discharge capacity retained). The parallel assembly reached end of life more rapidly for reasons unknown prior to CT investigations. The investigation revealed evidence of overdischarge in the most degraded cell from the parallel assembly, compared to more traditional failure in the individual cell. The parallel-wired cell exhibited dissolution of copper from the anode current collector and subsequent deposition throughout the separator near the cathode of the cell. This overdischarge-induced copper deposition, notably impossible to confirm with other state of health (SOH) monitoring methods, is diagnosed using CT by rendering the interior current collector without harm or alteration to the active materials. Correlation of CT observations to the electrochemical pulse data from the parallel-wired cells reveals the risk of parallel wiring during high C-rate pulse discharge.
Spacewire on Earth orbiting scatterometers
NASA Technical Reports Server (NTRS)
Bachmann, Alex; Lang, Minh; Lux, James; Steffke, Richard
2002-01-01
The need for a high speed, reliable and easy to implement communication link has led to the development of a space flight oriented version of IEEE 1355 called SpaceWire. SpaceWire is based on high-speed (200 Mbps) serial point-to-point links using Low Voltage Differential Signaling (LVDS). SpaceWIre has provisions for routing messages between a large network of processors, using wormhole routing for low overhead and latency. {additionally, there are available space qualified hybrids, which provide the Link layer to the user's bus}. A test bed of multiple digital signal processor breadboards, demonstrating the ability to meet signal processing requirements for an orbiting scatterometer has been implemented using three Astrium MCM-DSPs, each breadboard consists of a Multi Chip Module (MCM) that combines a space qualified Digital Signal Processor and peripherals, including IEEE-1355 links. With the addition of appropriate physical layer interfaces and software on the DSP, the SpaceWire link is used to communicate between processors on the test bed, e.g. sending timing references, commands, status, and science data among the processors. Results are presented on development issues surrounding the use of SpaceWire in this environment, from physical layer implementation (cables, connectors, LVDS drivers) to diagnostic tools, driver firmware, and development methodology. The tools, methods, and hardware, software challenges and preliminary performance are investigated and discussed.
A numerical method for measuring capacitive soft sensors through one channel
NASA Astrophysics Data System (ADS)
Tairych, Andreas; Anderson, Iain A.
2018-03-01
Soft capacitive stretch sensors are well suited for unobtrusive wearable body motion capture. Conventional sensing methods measure sensor capacitances through separate channels. In sensing garments with many sensors, this results in high wiring complexity, and a large footprint of rigid sensing circuit boards. We have developed a more efficient sensing method that detects multiple sensors through only one channel, and one set of wires. It is based on a R-C transmission line assembled from capacitive conductive fabric stretch sensors, and external resistors. The unknown capacitances are identified by solving a system of nonlinear equations. These equations are established by modelling and continuously measuring transmission line reactances at different frequencies. Solving these equations numerically with a Newton-Raphson solver for the unknown capacitances enables real time reading of all sensors. The method was verified with a prototype comprising three sensors that is capable of detecting both individually and simultaneously stretched sensors. Instead of using three channels and six wires to detect the sensors, the task was achieved with only one channel and two wires.
Generation of extreme state of water by spherical wire array underwater electrical explosion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antonov, O.; Gilburd, L.; Efimov, S.
2012-10-15
The results of the first experiments on the underwater electrical explosion of a spherical wire array generating a converging strong shock wave are reported. Using a moderate pulse power generator with a stored energy of {<=}6 kJ and discharge current of {<=}500 kA with a rise-time of {approx}300 ns, explosions of Cu and Al wire arrays of different diameters and with a different number and diameter of wires were tested. Electrical, optical, and destruction diagnostics were used to determine the energy deposited into the array, the time-of-flight of the shock wave to the origin of the implosion, and the parametersmore » of water at that location. The experimental and numerical simulation results indicate that the convergence of the shock wave leads to the formation of an extreme state of water in the vicinity of the implosion origin that is characterized by pressure, temperature, and compression factors of (2 {+-} 0.2) Multiplication-Sign 10{sup 12} Pa, 8 {+-} 0.5 eV, and 7 {+-} 0.5, respectively.« less
NASA Astrophysics Data System (ADS)
Ghaysari, N.; Ataei, M.; Sereshki, F.; Mikaiel, R.
2012-12-01
In this study, prediction of production rate in diamond wire saw has been investigated. Performance measurements of diamond wire saw carried out in 7 different quarries of carbonate rocks in Iran. For determination textural properties, rock samples were collected from these quarries. At first, a thin section was prepared for each rock and then 5 digital photographs were taken from each section. After this, all images were digitized using AutoCAD software. Then, area, perimeter, longest diameter and shortest diameter were assigned. According to these parameters, all of the other textural characteristics and texture coefficient were determined too. The correlation between sawing rate and textural characteristics were evaluated using multiple and simple regression analyses. Then developed model was validated by P-value test. It was concluded that area, perimeter, diameter equivalent and index of grain size homogeneity are very effective on production rate. Production rate using diamond wire saw can reliably be predicted using developed model.
Anomalous length dependence of conductance of aromatic nanoribbons with amine anchoring groups
NASA Astrophysics Data System (ADS)
Bilić, Ante; Sanvito, Stefano
2012-09-01
Two sets of aromatic nanoribbons, based around a common hexagonal scaffolding, with single and dual terminal amine groups have been considered as potential molecular wires in a junction formed by gold leads. Charge transport through the two-terminal device has been modeled using density functional theory (with and without self-interaction correction) and the nonequilibrium Green's function method. The effects of wire length, multiple terminal contacts, and pathways across the junction have been investigated. For nanoribbons with the oligopyrene motif and conventional single amine terminal groups, an increase in the wire length causes an exponential drop in the conductance. In contrast, for the nanoribbons with the oligoperylene motif and dual amine anchoring groups the predicted conductance rises with the wire length over the whole range of investigated lengths. Only when the effects of self-interaction correction are taken into account, the conductance of the oligoperylene ribbons exhibits saturation for longer members of the series. The oligoperylene nanoribbons, with dual amine groups at both terminals, show the potential to fully harness the highly conjugated system of π molecular orbitals across the junction.
Effect of time and pH on physical-chemical properties of orthodontic brackets and wires.
Dos Santos, Aretha Aliny Ramos; Pithon, Matheus Melo; Carlo, Fabíola Galbiatti Carvalho; Carlo, Hugo Lemes; de Lima, Bruno Alessandro Silva Guedes; Dos Passos, Tibério Andrade; Lacerda-Santos, Rogério
2015-03-01
To test the hypothesis that treatment time, debris/biofilm, and oral pH have an influence on the physical-chemical properties of orthodontic brackets and arch wires. One hundred twenty metal brackets were evaluated. They were divided into four groups (n = 30) according to treatment time: group C (control) and groups T12, T24, and T36 (brackets recovered after 12, 24, and 36 months of treatment, respectively). Rectangular stainless-steel arch wires that remained in the oral cavity for 12 to 24 months were also analyzed. Dimensional stability, surface morphology, composition of brackets, resistance to sliding of the bracket-wire set, surface roughness of wires, and oral pH were analyzed. One-way analysis of variance, followed by a Tukey multiple comparisons test, was used for statistical analysis (P < .05). Carbon and oxygen were shown to be elements that increased expressively and in direct proportion to time, and there was a progressive increase in the coefficient of friction and roughness of wires as a function of time of clinical use after 36 months. Oral pH showed a significant difference between group T36 and its control (P = .014). The hypothesis was partially accepted: treatment time and biofilm and debris accumulation in bracket slots were shown to have more influence on the degradation process and frictional force of these devices than did oral pH.
Shielded high-Tc bscco tapes or wires for high field applications
Balachandran, Uthamalingam; Lelovic, Milan; Eror, Nicholas G.
2002-01-01
A composite superconductor having an interior component of multiple filaments of superconducting Bi-2223 sheathed in a Ag or Ag alloy material, and a RE, TI or Hg based superconductor surrounding the interior component.
Shielded high-TC BSCCO tapes or wires for high field applications
Balachandran, Uthamalingam; Lelovic, Milan; Eror, Nicholas G.
2001-01-01
A composite superconductor having an interior component of multiple filaments of superconducting Bi-2223 sheathed in a Ag or Ag alloy material, and a RE, TI or Hg based superconductor surrounding the interior component.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Dong; Heidelberger, Philip; Sugawara, Yutaka
An apparatus and method for extending the scalability and improving the partitionability of networks that contain all-to-all links for transporting packet traffic from a source endpoint to a destination endpoint with low per-endpoint (per-server) cost and a small number of hops. An all-to-all wiring in the baseline topology is decomposed into smaller all-to-all components in which each smaller all-to-all connection is replaced with star topology by using global switches. Stacking multiple copies of the star topology baseline network creates a multi-planed switching topology for transporting packet traffic. Point-to-point unified stacking method using global switch wiring methods connects multiple planes ofmore » a baseline topology by using the global switches to create a large network size with a low number of hops, i.e., low network latency. Grouped unified stacking method increases the scalability (network size) of a stacked topology.« less
NASA Astrophysics Data System (ADS)
Chen, Yen-Sheng; Zhou, Huang-Cheng
2017-05-01
This paper presents a multiple-input-multiple-output (MIMO) antenna that has four-unit elements enabled by an isolation technique for long-term evolution (LTE) small-cell base stations. While earlier studies on MIMO base-station antennas cope with either a lower LTE band (698-960 MHz) or an upper LTE band (1710-2690 MHz), the proposed antenna meets the full LTE specification, yet it uses the maximum number of unit elements to increase channel capacity. The antenna configuration is optimized for good impedance matching and high radiation efficiency. In particular, as the spacing between unit elements is so small that severe mutual coupling occurs, we propose a simple structure with extremely low costs to enhance the isolation. By using suspended solid wires interconnecting the position having strong coupled current of two adjacent elements, an isolation enhancement of 37 dB is achieved. Although solid wires inherently aim at direct-current applications, this work successfully employs such a low-cost technique to microwave antenna development. Experimental results have validated the design guidelines and the proposed configuration, showing that antenna performances including impedance matching, isolation, radiation features, signal correlation, and channel capacity gain are highly desired for LTE small-cell base stations.
Three-body effects in Casimir-Polder repulsion
NASA Astrophysics Data System (ADS)
Milton, Kimball A.; Abalo, E. K.; Parashar, Prachi; Pourtolami, Nima; Brevik, Iver; Ellingsen, Simen Å.; Buhmann, Stefan Yoshi; Scheel, Stefan
2015-04-01
In this paper we study an archetypical scenario in which repulsive Casimir-Polder forces between an atom or molecule and two macroscopic bodies can be achieved. This is an extension of previous studies of the interaction between a polarizable atom and a wedge, in which repulsion occurs if the atom is sufficiently anisotropic and close enough to the symmetry plane of the wedge. A similar repulsion occurs if such an atom passes a thin cylinder or a wire. An obvious extension is to compute the interaction between such an atom and two facing wedges, which includes as a special case the interaction of an atom with a conducting screen possessing a slit, or between two parallel wires. To this end we further extend the electromagnetic multiple-scattering formalism for three-body interactions. To test this machinery we reinvestigate the interaction of a polarizable atom between two parallel conducting plates. In that case, three-body effects are shown to be small and are dominated by three- and four-scattering terms. The atom-wedge calculation is illustrated by an analogous scalar situation, described in the Appendix. The wedge-wedge-atom geometry is difficult to analyze because this is a scale-free problem. However, it is not so hard to investigate the three-body corrections to the interaction between an anisotropic atom or nanoparticle and a pair of parallel conducting cylinders and show that the three-body effects are very small and do not affect the Casimir-Polder repulsion at large distances between the cylinders. Finally, we consider whether such highly anisotropic atoms needed for repulsion are practically realizable. Since this appears rather difficult to accomplish, it may be more feasible to observe such effects with highly anisotropic nanoparticles.
Action Potential Waveform Variability Limits Multi-Unit Separation in Freely Behaving Rats
Stratton, Peter; Cheung, Allen; Wiles, Janet; Kiyatkin, Eugene; Sah, Pankaj; Windels, François
2012-01-01
Extracellular multi-unit recording is a widely used technique to study spontaneous and evoked neuronal activity in awake behaving animals. These recordings are done using either single-wire or mulitwire electrodes such as tetrodes. In this study we have tested the ability of single-wire electrodes to discriminate activity from multiple neurons under conditions of varying noise and neuronal cell density. Using extracellular single-unit recording, coupled with iontophoresis to drive cell activity across a wide dynamic range, we studied spike waveform variability, and explored systematic differences in single-unit spike waveform within and between brain regions as well as the influence of signal-to-noise ratio (SNR) on the similarity of spike waveforms. We also modelled spike misclassification for a range of cell densities based on neuronal recordings obtained at different SNRs. Modelling predictions were confirmed by classifying spike waveforms from multiple cells with various SNRs using a leading commercial spike-sorting system. Our results show that for single-wire recordings, multiple units can only be reliably distinguished under conditions of high recording SNR (≥4) and low neuronal density (≈20,000/ mm3). Physiological and behavioural changes, as well as technical limitations typical of awake animal preparations, reduce the accuracy of single-channel spike classification, resulting in serious classification errors. For SNR <4, the probability of misclassifying spikes approaches 100% in many cases. Our results suggest that in studies where the SNR is low or neuronal density is high, separation of distinct units needs to be evaluated with great caution. PMID:22719894
Adaptive Code Division Multiple Access Protocol for Wireless Network-on-Chip Architectures
NASA Astrophysics Data System (ADS)
Vijayakumaran, Vineeth
Massive levels of integration following Moore's Law ushered in a paradigm shift in the way on-chip interconnections were designed. With higher and higher number of cores on the same die traditional bus based interconnections are no longer a scalable communication infrastructure. On-chip networks were proposed enabled a scalable plug-and-play mechanism for interconnecting hundreds of cores on the same chip. Wired interconnects between the cores in a traditional Network-on-Chip (NoC) system, becomes a bottleneck with increase in the number of cores thereby increasing the latency and energy to transmit signals over them. Hence, there has been many alternative emerging interconnect technologies proposed, namely, 3D, photonic and multi-band RF interconnects. Although they provide better connectivity, higher speed and higher bandwidth compared to wired interconnects; they also face challenges with heat dissipation and manufacturing difficulties. On-chip wireless interconnects is one other alternative proposed which doesn't need physical interconnection layout as data travels over the wireless medium. They are integrated into a hybrid NOC architecture consisting of both wired and wireless links, which provides higher bandwidth, lower latency, lesser area overhead and reduced energy dissipation in communication. However, as the bandwidth of the wireless channels is limited, an efficient media access control (MAC) scheme is required to enhance the utilization of the available bandwidth. This thesis proposes using a multiple access mechanism such as Code Division Multiple Access (CDMA) to enable multiple transmitter-receiver pairs to send data over the wireless channel simultaneously. It will be shown that such a hybrid wireless NoC with an efficient CDMA based MAC protocol can significantly increase the performance of the system while lowering the energy dissipation in data transfer. In this work it is shown that the wireless NoC with the proposed CDMA based MAC protocol outperformed the wired counterparts and several other wireless architectures proposed in literature in terms of bandwidth and packet energy dissipation. Significant gains were observed in packet energy dissipation and bandwidth even with scaling the system to higher number of cores. Non-uniform traffic simulations showed that the proposed CDMA-WiNoC was consistent in bandwidth across all traffic patterns. It is also shown that the CDMA based MAC scheme does not introduce additional reliability concerns in data transfer over the on-chip wireless interconnects.
Sleeve Push Technique: A Novel Method of Space Gaining.
Verma, Sanjeev; Bhupali, Nameksh Raj; Gupta, Deepak Kumar; Singh, Sombir; Singh, Satinder Pal
2018-01-01
Space gaining is frequently required in orthodontics. Multiple loops were initially used for space gaining and alignment. The most common used mechanics for space gaining is the use of nickel-titanium open coil springs. The disadvantage of nickel-titanium coil spring is that they cannot be used until the arches are well aligned to receive the stiffer stainless steel wires. Therefore, a new method of gaining space during initial alignment and leveling has been developed and named as sleeve push technique (SPT). The nickel-titanium wires, i.e. 0.012 inches and 0.014 inches along with archwire sleeve (protective tubing) can be used in a modified way to gain space along with alignment. This method helps in gaining space right from day 1 of treatment. The archwire sleeve and nickel-titanium wire in this new SPT act as a mutually synergistic combination and provide the orthodontist with a completely new technique for space opening.
Suppression of background noise in a transonic wind-tunnel test section
NASA Technical Reports Server (NTRS)
Schutzenhofer, L. A.; Howard, P. W.
1975-01-01
Some exploratory tests were recently performed in the transonic test section of the NASA Marshall Space Flight Center 14-in. wind tunnel to suppress the background noise. In these tests, the perforated walls of the test section were covered with fine wire screens. The screens eliminated the edge tones generated by the holes in the perforated walls and significantly reduced the tunnel background noise. The tunnel noise levels were reduced to such a degree by this simple modification at Mach numbers 0.75, 0.9, 1.1, 1.2, and 1.46 that the fluctuating pressure levels of a turbulent boundary layer could be measured on a 5-deg half-angle cone.
Low Cost Dewatering of Waste Slurries
NASA Technical Reports Server (NTRS)
Peterson, J. B.; Sharma, S. K.; Church, R. H.; Scheiner, B. J.
1993-01-01
The U.S. Bureau of Mines has developed a technique for dewatering mineral waste slurries which utilizes polymer and a static screen. A variety of waste slurries from placer gold mines and crushed stone operations have been successfully treated using the system. Depending on the waste, a number of polymers have been used successfully with polymer costs ranging from $0.05 to $0.15 per 1,000 gal treated. The dewatering is accomplished using screens made from either ordinary window screen or wedge wire. The screens used are 8 ft wide and 8 ft long. The capacity of the screens varies from 3 to 7 gpm/sq. ft. The water produced is acceptable for recycling to the plant or for discharge to the environment. For example, a fine grain dolomite waste slurry produced from a crushed stone operation was dewatered from a nominal 2.5 pct solids to greater than 50 pct solids using $0.10 to $0.15 worth of polymer per 1,000 gal of slurry. The resulting waste water had a turbidity of less than 50 NTU and could be discharged or recycled. The paper describes field tests conducted using the polymer-screen dewatering system.
Three-dimensional hologram display system
NASA Technical Reports Server (NTRS)
Mintz, Frederick (Inventor); Chao, Tien-Hsin (Inventor); Bryant, Nevin (Inventor); Tsou, Peter (Inventor)
2009-01-01
The present invention relates to a three-dimensional (3D) hologram display system. The 3D hologram display system includes a projector device for projecting an image upon a display medium to form a 3D hologram. The 3D hologram is formed such that a viewer can view the holographic image from multiple angles up to 360 degrees. Multiple display media are described, namely a spinning diffusive screen, a circular diffuser screen, and an aerogel. The spinning diffusive screen utilizes spatial light modulators to control the image such that the 3D image is displayed on the rotating screen in a time-multiplexing manner. The circular diffuser screen includes multiple, simultaneously-operated projectors to project the image onto the circular diffuser screen from a plurality of locations, thereby forming the 3D image. The aerogel can use the projection device described as applicable to either the spinning diffusive screen or the circular diffuser screen.
Applying a cloud computing approach to storage architectures for spacecraft
NASA Astrophysics Data System (ADS)
Baldor, Sue A.; Quiroz, Carlos; Wood, Paul
As sensor technologies, processor speeds, and memory densities increase, spacecraft command, control, processing, and data storage systems have grown in complexity to take advantage of these improvements and expand the possible missions of spacecraft. Spacecraft systems engineers are increasingly looking for novel ways to address this growth in complexity and mitigate associated risks. Looking to conventional computing, many solutions have been executed to solve both the problem of complexity and heterogeneity in systems. In particular, the cloud-based paradigm provides a solution for distributing applications and storage capabilities across multiple platforms. In this paper, we propose utilizing a cloud-like architecture to provide a scalable mechanism for providing mass storage in spacecraft networks that can be reused on multiple spacecraft systems. By presenting a consistent interface to applications and devices that request data to be stored, complex systems designed by multiple organizations may be more readily integrated. Behind the abstraction, the cloud storage capability would manage wear-leveling, power consumption, and other attributes related to the physical memory devices, critical components in any mass storage solution for spacecraft. Our approach employs SpaceWire networks and SpaceWire-capable devices, although the concept could easily be extended to non-heterogeneous networks consisting of multiple spacecraft and potentially the ground segment.
Gomes, Ana L.; Kinchesh, Paul; Kersemans, Veerle; Allen, Philip D.; Smart, Sean C.
2016-01-01
Purpose To develop an MRI-compatible resistive heater, using high frequency alternating current (AC), for temperature maintenance of anaesthetised animals. Materials and Methods An MRI-compatible resistive electrical heater was formed from narrow gauge wire connected to a high frequency (10–100 kHz) AC power source. Multiple gradient echo images covering a range of echo times, and pulse-acquire spectra were acquired with the wire heater powered using high frequency AC or DC power sources and without any current flowing in order to assess the sensitivity of the MRI acquisitions to the presence of current flow through the heater wire. The efficacy of temperature maintenance using the AC heater was assessed by measuring rectal temperature immediately following induction of general anaesthesia for a period of 30 minutes in three different mice. Results Images and spectra acquired in the presence and absence of 50–100 kHz AC through the wire heater were indistinguishable, whereas DC power created field shifts and lineshape distortions. Temperature lost during induction of anaesthesia was recovered within approximately 20 minutes and a stable temperature was reached as the mouse’s temperature approached the set target. Conclusion The AC-powered wire heater maintains adequate heat input to the animal to maintain body temperature, and does not compromise image quality. PMID:27806062
NASA Astrophysics Data System (ADS)
Matsuda, Y.; Nonomura, T.; Kakutani, K.; Kimbara, J.; Osamura, K.; Kusakari, S.; Toyoda, H.
2015-10-01
An electric field screen is a physical device used to exclude pest insects from greenhouses and warehouses to protect crop production and storage. The screen consists of iron insulated conductor wires (ICWs) arrayed in parallel and linked to each other, an electrostatic DC voltage generator used to supply a negative charge to the ICWs, and an earthed stainless net placed on one side of the ICW layer. The ICW was negatively charged to polarize the earthed net to create a positive charge on the ICW side surface, and an electric field formed between the opposite charges of the ICW and earthed net. The current study focused on the ability of the screen to repel insects reaching the screen net. This repulsion was a result of the insect's behaviour, i.e., the insects were deterred from entering the electric field of the screen. In fact, when the screen was negatively charged with the appropriate voltages, the insects placed their antennae inside the screen and then flew away without entering. Obviously, the insects recognized the electric field using their antennae and thereby avoided entering. Using a wide range of insects and spiders belonging to different taxonomic groups, we confirmed that the avoidance response to the electric field was common in these animals.
Modeling of a stacked-screen regenerator in an oscillatory flow
NASA Astrophysics Data System (ADS)
Hsu, Shu Han; Biwa, Tetsushi
2017-01-01
In this paper, we model tortuous flow channels of a stacked-screen regenerator as a bundle of cylindrical tubes to analyze and design thermoacoustic Stirling engines. The oscillatory flow resistance of stacked-screen regenerators is measured and compared with those obtained using empirical equations to verify the applicability of those empirical equations to oscillating flows of pressurized Ar and He gases. It is then converted to an effective radius parameterized by Re h and r 0/δν, where Re h represents the Reynolds number based on velocity oscillation amplitude, r 0 is Ueda’s effective radius ( = \\sqrt{d\\text{h}D} /2, where d h is the hydraulic diameter and D is the mesh wire diameter), and δν denotes the viscous penetration depth. The applicability of the proposed effective radius is demonstrated experimentally when the axial temperature gradient is imposed on the regenerator.
Apparatus for monitoring two-phase flow
Sheppard, John D.; Tong, Long S.
1977-03-01
A method and apparatus for monitoring two-phase flow is provided that is particularly related to the monitoring of transient two-phase (liquid-vapor) flow rates such as may occur during a pressurized water reactor core blow-down. The present invention essentially comprises the use of flanged wire screens or similar devices, such as perforated plates, to produce certain desirable effects in the flow regime for monitoring purposes. One desirable effect is a measurable and reproducible pressure drop across the screen. The pressure drop can be characterized for various known flow rates and then used to monitor nonhomogeneous flow regimes. Another useful effect of the use of screens or plates in nonhomogeneous flow is that such apparatus tends to create a uniformly dispersed flow regime in the immediate downstream vicinity. This is a desirable effect because it usually increases the accuracy of flow rate measurements determined by conventional methods.
Method and apparatus for monitoring two-phase flow. [PWR
Sheppard, J.D.; Tong, L.S.
1975-12-19
A method and apparatus for monitoring two-phase flow is provided that is particularly related to the monitoring of transient two-phase (liquid-vapor) flow rates such as may occur during a pressurized water reactor core blow-down. The present invention essentially comprises the use of flanged wire screens or similar devices, such as perforated plates, to produce certain desirable effects in the flow regime for monitoring purposes. One desirable effect is a measurable and reproducible pressure drop across the screen. The pressure drop can be characterized for various known flow rates and then used to monitor nonhomogeneous flow regimes. Another useful effect of the use of screens or plates in nonhomogeneous flow is that such apparatus tends to create a uniformly dispersed flow regime in the immediate downstream vicinity. This is a desirable effect because it usually increases the accuracy of flow rate measurements determined by conventional methods.
Primary experimental results of wire-array Z-pinches on PTS
NASA Astrophysics Data System (ADS)
Huang, X. B.; Zhou, S. T.; Ren, X. D.; Dan, J. K.; Wang, K. L.; Zhang, S. Q.; Li, J.; Xu, Q.; Cai, H. C.; Duan, S. C.; Ouyang, K.; Chen, G. H.; Ji, C.; Wang, M.; Feng, S. P.; Yang, L. B.; Xie, W. P.; Deng, J. J.
2014-12-01
The Primary Test Stand (PTS) developed at the China Academy of Engineering Physics is a multiterawatt pulsed power driver, which can deliver a ˜10 MA, 70 ns rise-time (10%-90%) current to a short circuit load and has important applications in Z-pinch driven inertial confinement fusion and high energy density physics. In this paper, primary results of tungsten wire-array Z-pinch experiments on PTS are presented. The load geometries investigated include 15-mm-tall cylindrical single and nested arrays with diameter ranging from 14.4-26.4 mm, and consisting of 132˜276 tungsten wires with 5˜10 μm in diameter. Multiple diagnostics were fielded to determine the characteristics of x-ray radiations and to obtain self-emitting images of imploding plasmas. X-ray power up to 80 TW with ˜3 ns FWMH is achieved by using nested wire arrays. The total x-ray energy exceeds 500 kJ and the peak radiation temperature is about 150 eV. Typical velocity of imploding plasmas goes around 3˜5×107 cm/s and the radial convergence ratio is between 10 and 20.
Cryogenic and radiation-hard asic for interfacing large format NIR/SWIR detector arrays
NASA Astrophysics Data System (ADS)
Gao, Peng; Dupont, Benoit; Dierickx, Bart; Müller, Eric; Verbruggen, Geert; Gielis, Stijn; Valvekens, Ramses
2017-11-01
For scientific and earth observation space missions, weight and power consumption is usually a critical factor. In order to obtain better vehicle integration, efficiency and controllability for large format NIR/SWIR detector arrays, a prototype ASIC is designed. It performs multiple detector array interfacing, power regulation and data acquisition operations inside the cryogenic chambers. Both operation commands and imaging data are communicated via the SpaceWire interface which will significantly reduce the number of wire goes in and out the cryogenic chamber. This "ASIC" prototype is realized in 0.18um CMOS technology and is designed for radiation hardness.
Thermal resilient multiple jaw braze fixture
Ney, Robert; Perrone, Alex J.
1995-07-11
A braze fixture has side walls forming a cavity with an opening to receive a stack of parts to be brazed. Sidewalls of the housing have a plurality of bearing receiving openings into which bearing rods or jaws are inserted to align the stacked elements of the workpiece. The housing can also have view ports to allow a visual check of the alignment. Straps or wires around the fixture are selected to have thermal characteristics similar to the thermal characteristics of the workpiece undergoing brazing. The straps or wires make physical contact with the bearing rods thereby causing bearing rods to maintain the workpiece in proper alignment throughout the entire brazing cycle.
Vertical epitaxial wire-on-wire growth of Ge/Si on Si(100) substrate.
Shimizu, Tomohiro; Zhang, Zhang; Shingubara, Shoso; Senz, Stephan; Gösele, Ulrich
2009-04-01
Vertically aligned epitaxial Ge/Si heterostructure nanowire arrays on Si(100) substrates were prepared by a two-step chemical vapor deposition method in anodic aluminum oxide templates. n-Butylgermane vapor was employed as new safer precursor for Ge nanowire growth instead of germane. First a Si nanowire was grown by the vapor liquid solid growth mechanism using Au as catalyst and silane. The second step was the growth of Ge nanowires on top of the Si nanowires. The method presented will allow preparing epitaxially grown vertical heterostructure nanowires consisting of multiple materials on an arbitrary substrate avoiding undesired lateral growth.
A novel biomechanical model assessing continuous orthodontic archwire activation
Canales, Christopher; Larson, Matthew; Grauer, Dan; Sheats, Rose; Stevens, Clarke; Ko, Ching-Chang
2013-01-01
Objective The biomechanics of a continuous archwire inserted into multiple orthodontic brackets is poorly understood. The purpose of this research was to apply the birth-death technique to simulate insertion of an orthodontic wire and consequent transfer of forces to the dentition in an anatomically accurate model. Methods A digital model containing the maxillary dentition, periodontal ligament (PDL), and surrounding bone was constructed from human computerized tomography data. Virtual brackets were placed on four teeth (central and lateral incisors, canine and first premolar), and a steel archwire (0.019″ × 0.025″) with a 0.5 mm step bend to intrude the lateral incisor was virtually inserted into the bracket slots. Forces applied to the dentition and surrounding structures were simulated utilizing the birth-death technique. Results The goal of simulating a complete bracket-wire system on accurate anatomy including multiple teeth was achieved. Orthodontic force delivered by the wire-bracket interaction was: central incisor 19.1 N, lateral incisor 21.9 N, and canine 19.9 N. Loading the model with equivalent point forces showed a different stress distribution in the PDL. Conclusions The birth-death technique proved to be a useful biomechanical simulation method for placement of a continuous archwire in orthodontic brackets. The ability to view the stress distribution throughout proper anatomy and appliances advances understanding of orthodontic biomechanics. PMID:23374936
An efficient miniature 120 Hz pulse tube cryocooler using high porosity regenerator material
NASA Astrophysics Data System (ADS)
Yu, Huiqin; Wu, Yinong; Ding, Lei; Jiang, Zhenhua; Liu, Shaoshuai
2017-12-01
A 1.22 kg coaxial miniature pulse tube cryocooler (MPTC) has been fabricated and tested in our laboratory to provide cooling for cryogenic applications demanding compactness, low mass and rapid cooling rate. The geometrical parameters of regenerator, pulse tube and phase shifter are optimized. The investigation demonstrates that using higher mesh number and thinner wire diameter of stainless steel screen (SSS) can promote the coefficient of performance (COP) when the MPTC operates at 120 Hz. In this study, the 604 mesh SSS with 17 μm diameter of mesh wire is constructed as filler of regenerator. The experimental results show the MPTC operating at 120 Hz achieves a no-load temperature of 53.5 K with 3.8 MPa charging pressure, and gets a cooling power of 2 W at 80 K with 55 W input electric power which has a relative Carnot efficiency of 9.68%.
Laser Scanner For Automatic Inspection Of Printed Wiring Boards
NASA Astrophysics Data System (ADS)
Geise, Philip; George, Eugene; Freese, Fritz; Brown, Robert; Ruwe, Victor
1980-11-01
An, Instrument is described which inspects unpopulated, populated (components onserted and leads clinched), and soldered printed wiring boards for correct hole location, component presence, correct lead clinch direction and solder bridges. The instrument consists of a low power heliumneon laser, an x-y moving iron galvanometer scanner and several folding mirros. A unique shadow signature is detected by silicon photodiodes located at the optium geometry to allow rapid and reliable detection of components with correctly clinched leads. A reflective glint screen is utilized to inspect for a solder bridges. The detected signal are processed and evaluated by a minocomputer which also controls the scan inspection rate of at least 25 components or 50 components holes per second. The return of investment on this instrument for high volume production of printed wirind boards is less than one yea and only slightly longer for medium run military application.
Flexible fiber batteries for applications in smart textiles
NASA Astrophysics Data System (ADS)
Qu, Hang; Semenikhin, Oleg; Skorobogatiy, Maksim
2015-02-01
In this paper, we demonstrate flexible fiber-based Al-NaOCl galvanic cells fabricated using fiber drawing process. Aluminum and copper wires are used as electrodes, and they are introduced into the fiber structure during drawing of the low-density polyethylene microstructured jacket. NaOCl solution is used as electrolyte, and it is introduced into the battery after the drawing process. The capacity of a 1 m long fiber battery is measured to be ˜10 mAh. We also detail assembly and optimization of the electrical circuitry in the energy-storing fiber battery textiles. Several examples of their applications are presented including lighting up an LED, driving a wireless mouse and actuating a screen with an integrated shape-memory nitinol wire. The principal advantages of the presented fiber batteries include: ease of fabrication, high flexibility, simple electrochemistry and use of widely available materials in the battery design.
[Methods of resolution for haptic assistance during catheterization].
Kern, T A; Herrmann, J; Klages, S; Meiss, T; Werthschützky, R
2005-01-01
During catheterization navigation within the patient is mainly dependent on a live x-ray image on the screen. Although methods for 3D visualisation and remote navigation of the catheter are discussed and tested still precise positioning is merely the result of intense training and a high skill and level of training of the performing surgeon. This article refers to a system which can be considered as an add-on for existing procedures of catheterization. It compromises of a miniaturised force sensor located at the tip of guide-wires whose prototype is shown here. The measured forces will be presented to the surgeon amplified by an external actuator described in this article. As a result a haptic perception of the forces between the tip of the guide-wire and the vessels walls will be available and enable the surgeon to gain an impression which is comparable to palpation of living vessels from the inside
The controlled relay of multiple protons required at the active site of nitrogenase.
Dance, Ian
2012-07-07
The enzyme nitrogenase, when reducing natural and unnatural substrates, requires large numbers of protons per chemical catalytic cycle. The active face of the catalytic site (the FeMo-cofactor, FeMo-co) is situated in a protein domain which is largely hydrophobic and anhydrous, and incapable of serial provision of multiple protons. Through detailed analysis of the high quality protein crystal structures available the characteristics of a chain of water molecules leading from the protein surface to a key sulfur atom (S3B) of FeMo-co are described. The first half of the water chain from the surface inwards is branched, slightly variable, and able to accommodate exogenous small molecules: this is dubbed the proton bay. The second half, from the proton bay to S3B, is comprised of a single chain of eight hydrogen bonded water molecules. This section is strictly conserved, and is intimately involved in hydrogen bonds with homocitrate, an essential component that chelates Mo. This is the proton wire, and a detailed Grotthuss mechanism for serial translocation of protons through this proton wire to S3B is proposed. This controlled serial proton relay from the protein surface to S3B is an essential component of the intramolecular hydrogenation paradigm for the complete chemical mechanisms of nitrogenase. Each proton reaching S3B, instigated by electron transfer to FeMo-co, becomes a hydrogen atom that migrates to other components of the active face of FeMo-co and to bound substrates and intermediates, allowing subsequent multiple proton transfers along the proton wire. Experiments to test the proposed mechanism of proton supply are suggested. The water chain in nitrogenase is comparable with the purported proton pumping pathway of cytochrome c oxidase.
Scalable screen-size enlargement by multi-channel viewing-zone scanning holography.
Takaki, Yasuhiro; Nakaoka, Mitsuki
2016-08-08
Viewing-zone scanning holographic displays can enlarge both the screen size and the viewing zone. However, limitations exist in the screen size enlargement process even if the viewing zone is effectively enlarged. This study proposes a multi-channel viewing-zone scanning holographic display comprising multiple projection systems and a planar scanner to enable the scalable enlargement of the screen size. Each projection system produces an enlarged image of the screen of a MEMS spatial light modulator. The multiple enlarged images produced by the multiple projection systems are seamlessly tiled on the planar scanner. This screen size enlargement process reduces the viewing zones of the projection systems, which are horizontally scanned by the planar scanner comprising a rotating off-axis lens and a vertical diffuser to enlarge the viewing zone. A screen size of 7.4 in. and a viewing-zone angle of 43.0° are demonstrated.
Proceedings of the ECOM Hybrid Microcircuit Symposium, 1976
1976-06-01
remove both stationary and moving clutter. The hex fast line receiver micrýocircuit is a thin film chip-and-wire microcircuit (shown in Figure 7) which...of the following: (a) multiple usage, (b) high volume production, or (c) moderate volume and multiple usage. These criteria are not hard and fast ...compounding when the circuit complexity increases. O particular concern are open or intermittent bonds, susceptibility to moisture and impurities in the
High-speed autoverifying technology for printed wiring boards
NASA Astrophysics Data System (ADS)
Ando, Moritoshi; Oka, Hiroshi; Okada, Hideo; Sakashita, Yorihiro; Shibutani, Nobumi
1996-10-01
We have developed an automated pattern verification technique. The output of an automated optical inspection system contains many false alarms. Verification is needed to distinguish between minor irregularities and serious defects. In the past, this verification was usually done manually, which led to unsatisfactory product quality. The goal of our new automated verification system is to detect pattern features on surface mount technology boards. In our system, we employ a new illumination method, which uses multiple colors and multiple direction illumination. Images are captured with a CCD camera. We have developed a new algorithm that uses CAD data for both pattern matching and pattern structure determination. This helps to search for patterns around a defect and to examine defect definition rules. These are processed with a high speed workstation and a hard-wired circuits. The system can verify a defect within 1.5 seconds. The verification system was tested in a factory. It verified 1,500 defective samples and detected all significant defects with only a 0.1 percent of error rate (false alarm).
NASA Astrophysics Data System (ADS)
Kagawa, Hideshi; Fujii, Go; Kajiwara, Kenichi; Kuroda, Daisuke; Suzuki, Takuya; Yamabe-Mitarai, Yoko; Murakami, Hideyuki; Ono, Yoshinori
2012-07-01
Haynes25 (L-605) is a common heat resistant alloy used in mono-propellant structures and screen materials for catalyst beds. The lifetime requirements for thrusters have expanded dramatically after studies conducted in the 1970s on mono-propellant materials used to extend the service life. The material design had long remained unchanged, and the L-605 was still used as thruster material due to its good heritage. However, some important incidents involving degradation were found during the test-unit break-up inspection following the thruster life tests. The Japanese research team focused on the L-605 degradations found on the catalyst bed screen mesh used for mono-propellant thruster and analysed the surface of the wire material and the cross- section of the wire screen mesh used in the life tests. The investigation showed that the degradation was caused by nitriding L-605 component elements. The team suggested that the brittle fracture was attributable to tungsten (W) carbides, which formed primarily in the grain boundaries, and chromium (Cr) nitride, which formed mainly in the parts in contact with the hot firing gas. The team also suggested the installation of a platinum coating on the material surface as a countermeasure L-605 nitric degradation. Inconel 625 is now selected as a mono-propellant structure material due to its marginal raw material characters and cost. The team believes that Inconel 625 does not form W carbides since it contains no tungsten component, but does contain Cr and Fe, which form nitrides easily. Therefore, the team agreed that for the Inconel 625, there was a need to evaluate changes in the microstructure and mechanical properties following exposure to hot nitrogen gases. This paper will describe these changes of Inconel 625.
Metallic oxide switches using thick film technology
NASA Technical Reports Server (NTRS)
Patel, D. N.; Williams, L., Jr.
1974-01-01
Metallic oxide thick film switches were processed on alumina substrates using thick film technology. Vanadium pentoxide in powder form was mixed with other oxides e.g., barium, strontium copper and glass frit, ground to a fine powder. Pastes and screen printable inks were made using commercial conductive vehicles and appropriate thinners. Some switching devices were processed by conventional screen printing and firing of the inks and commercial cermet conductor terminals on 96% alumina substrates while others were made by applying small beads or dots of the pastes between platinum wires. Static, and dynamic volt-ampere, and pulse tests indicate that the switching and self-oscillatory characteristics of these devices could make them useful in memory element, oscillator, and automatic control applications.
NASA Astrophysics Data System (ADS)
Epstein, A.; Briquet-Laugier, F.; Sheldon, S.; Boulin, C.
2000-04-01
Most of the X-ray multi-wire gas detectors used at the EMBL Hamburg outstation for time-resolved studies of biological samples are readout, using the delay line method. The main disadvantage of such readout systems is their event rate limitation introduced by the delay line and the required time to digital conversion step. They also lack the possibility to deal with multiple events. To overcome these limitations, a new approach for the complete readout system was introduced. The new linear detection system is based on the wire per wire approach where each individual wire is associated to preamplifier/discriminator/counter electronics channel. High-density, front-end electronics were designed around a fast current sensitive preamplifier. An eight-channel board was designed to include the preamplifiers-discriminators and the differential ECL drivers output stages. The detector front-end consists of 25 boards directly mounted inside the detector assembly. To achieve a time framing resolution as short as 10 /spl mu/s, very fast histogramming is required. The only way to implement this for a high number of channels (200 in our case) is by using a distributed system. The digital part of the system consists of a crate controller, up to 16 acquisition boards (capable of handling fast histogramming for up to 32-channels each) and an optical-link board (based on the Cypress "Hot-Link" chip set). Both the crate controller and the acquisition boards are based on a standard RISC microcontroller (IDT R3081) plug-in board. At present, a dedicated CAMAC module which we developed is used to interface the digital front-end acquisition crate to the host via the optical link.
Roe, S C
1997-01-01
Evaluate the mechanical properties of twist, loop, double loop, double-wrap and loop/twist cerclage. The initial tension generated by 18 cerclage of each type was determined using a materials testing machine after tying around a testing jig. Six wires from each type were distracted and the initial stiffness and yield load were determined. Yield behavior was further investigated in six wires of each type by determining the load required to reduce cerclage tension below 30 Newton (N) following and incremental (50 N) stepwise load and unload regimen. The amount of collapse of the simulated bone fragments that resulted in the reduction of initial tension to 30 N was measured for the final six wires of each group. Data were analyzed by analysis of variance and a multiple comparison test. Twist type cerclage generated less tension than loop-type cerclage. The yield load of these two types was similar. Double-loop and double-wrap cerclage generated superior tension and resisted a greater load before loosening. Loop/twist cerclage had an intermediate initial tension but had the greatest resistance to loading. In the collapse test, the greater the initial tension, the more collapse could occur before the wire was loose. For all types of cerclage wire fixation, a reduction of diameter of the testing jig of more than 1% caused loosening. Double-loop and double-wrap cerclage provide greater compression of fragments and resist loads associated with weight-bearing better than the twist and loop methods. Loop/twist cerclage may have advantages because of their superior resistance to loading. All cerclage will loosen if fracture fragments collapse.
Integrated Circuit Chip Improves Network Efficiency
NASA Technical Reports Server (NTRS)
2008-01-01
Prior to 1999 and the development of SpaceWire, a standard for high-speed links for computer networks managed by the European Space Agency (ESA), there was no high-speed communications protocol for flight electronics. Onboard computers, processing units, and other electronics had to be designed for individual projects and then redesigned for subsequent projects, which increased development periods, costs, and risks. After adopting the SpaceWire protocol in 2000, NASA implemented the standard on the Swift mission, a gamma ray burst-alert telescope launched in November 2004. Scientists and developers on the James Webb Space Telescope further developed the network version of SpaceWire. In essence, SpaceWire enables more science missions at a lower cost, because it provides a standard interface between flight electronics components; new systems need not be custom built to accommodate individual missions, so electronics can be reused. New protocols are helping to standardize higher layers of computer communication. Goddard Space Flight Center improved on the ESA-developed SpaceWire by enabling standard protocols, which included defining quality of service and supporting plug-and-play capabilities. Goddard upgraded SpaceWire to make the routers more efficient and reliable, with features including redundant cables, simultaneous discrete broadcast pulses, prevention of network blockage, and improved verification. Redundant cables simplify management because the user does not need to worry about which connection is available, and simultaneous broadcast signals allow multiple users to broadcast low-latency side-band signal pulses across the network using the same resources for data communication. Additional features have been added to the SpaceWire switch to prevent network blockage so that more robust networks can be designed. Goddard s verification environment for the link-and-switch implementation continuously randomizes and tests different parts, constantly anticipating situations, which helps improve communications reliability. It has been tested in many different implementations for compatibility.
Fatigue testing of controlled memory wire nickel-titanium rotary instruments.
Shen, Ya; Qian, Wei; Abtin, Houman; Gao, Yuan; Haapasalo, Markus
2011-07-01
To improve the fracture resistance of nickel-titanium (NiTi) files, manufacturers have introduced new alloys to manufacture NiTi files and developed new manufacturing processes. This study was aimed to examine the fatigue behavior of NiTi instruments from a novel controlled memory NiTi wire (CM Wire). Instruments of ProFile, Typhoon (TYP), Typhoon CM (TYP CM), DS-SS0250425NEYY (NEYY), and DS-SS0250425NEYY CM (NEYY CM) (DS Dental, Johnson City, TN) all size 25/.04 were subjected to rotational bending at the curvature of 35° and 45° in air at the temperature of 23° ± 2°C, and the number of revolutions to fracture (N(f)) was recorded. The fracture surface of all fragments was examined by a scanning electron microscope. The crack-initiation sites, the percentage of dimple area to the whole fracture cross-section, and the surface strain amplitude (ε(a)) were noted. The new alloy yielded an improvement of over three to eight times in N(f) of CM files than that of conventional NiTi files (P < .05). The vast majority of CM instruments (50%-92%) showed multiple crack origins, whereas most instruments made from conventional NiTi wire (58%-100%) had one crack origin. The values of the fraction area occupied by the dimple region were significantly smaller on CM NiTi instruments compared with conventional NiTi instruments (P < .01). The square (NEYY CM) versus the triangular (TYP CM) configuration showed a significantly different lifetime on CM wire at both curvatures (P < .01). The material property had a substantial impact on fatigue lifetime. Instruments made from CM Wire had a significantly higher N(f) and lower surface strain amplitude than the conventional NiTi wire files with identical design. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Shen, Ya; Qian, Wei; Abtin, Houman; Gao, Yuan; Haapasalo, Markus
2012-03-01
This study examined the fatigue behavior of 2 types of nickel-titanium (NiTi) instruments made from a novel controlled memory NiTi wire (CM wire) under various environment conditions. Three conventional superelastic NiTi instruments of ProFile (Dentsply Maillefer, Ballaigues, Switzerland), Typhoon (Clinician's Choice Dental Products, New Milford, CT), and DS-SS0250425NEYY (Clinician's Choice Dental Products) and 2 new CM wire instruments of Typhoon CM and DS-SS0250425NEYY CM were subjected to rotational bending at the curvature of 35° in air, deionized water, 17% EDTA, or deionized water after immersion in 6% sodium hypochlorite for 25 minutes, and the number of revolutions of fracture (N(f)) was recorded. The fracture surface of all fragments was examined by a scanning electron microscope. The crack-initiation sites and the percentage of dimple area to the whole fracture cross-section were noted. Two new CM Wire instruments yielded an improvement of >4 to 9 times in N(f) than conventional NiTi files with the same design under various environments (P < .05). The fatigue life of 3 conventional superelastic NiTi instruments was similar under various environments, whereas the N(f) of 2 new CM Wire instruments was significantly longer in liquid media than in air (P < .05). The vast majority of CM instruments showed multiple crack origins, whereas most instruments made from conventional NiTi wire had one crack origin. The values of the area fraction occupied by the dimple region were significantly smaller on CM NiTi instruments than in conventional NiTi instruments under various environments (P < .05). Within the limitations of this study, the type of NiTi metal alloy (CM files vs conventional superelastic NiTi files) influences the cyclic fatigue resistance under various environments. The fatigue life of CM instruments is longer in liquid media than in air. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Pointright: a system to redirect mouse and keyboard control among multiple machines
Johanson, Bradley E [Palo Alto, CA; Winograd, Terry A [Stanford, CA; Hutchins, Gregory M [Mountain View, CA
2008-09-30
The present invention provides a software system, PointRight, that allows for smooth and effortless control of pointing and input devices among multiple displays. With PointRight, a single free-floating mouse and keyboard can be used to control multiple screens. When the cursor reaches the edge of a screen it seamlessly moves to the adjacent screen and keyboard control is simultaneously redirected to the appropriate machine. Laptops may also redirect their keyboard and pointing device, and multiple pointers are supported simultaneously. The system automatically reconfigures itself as displays go on, go off, or change the machine they display.
Effect of screens in wide-angle diffusers
NASA Technical Reports Server (NTRS)
Schubauer, G B; Spangenberg, W G
1949-01-01
An experimental investigation at low airspeeds was made of the filling effect observed when a screen or similar resistance is placed across a diffuser. The filling effect is found to be real in that screens can prevent separation or restore separated flow in diffusers even of extreme divergence and to depend principally on screen location and pressure-drop coefficient of the screen. Results are given for three different diffusers of circular cross section with a variety of screen arrangements. Effects of single screens and multiple screens are shown. The mechanics of the filling effect is explained, and possible efficiencies are discussed. Results of arrangements of multiple screens in wide-angle diffusers are given to show a possible application to damping screens as used in wind tunnels to reduce turbulence. (author)
Iguchi, Toshihiro; Hiraki, Takao; Gobara, Hideo; Fujiwara, Hiroyasu; Matsui, Yusuke; Miyoshi, Shinichiro; Kanazawa, Susumu
2016-01-01
To retrospectively evaluate the safety of computed tomography (CT) fluoroscopy-guided short hook wire placement for video-assisted thoracoscopic surgery and the risk factors for pneumothorax associated with this procedure. We analyzed 267 short hook wire placements for 267 pulmonary lesions (mean diameter, 9.9 mm). Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for pneumothorax. Complications (219 grade 1 and 4 grade 2 adverse events) occurred in 196 procedures. No grade 3 or above adverse events were observed. Univariate analysis revealed increased vital capacity (odds ratio [OR], 1.518; P = 0.021), lower lobe lesion (OR, 2.343; P =0.001), solid lesion (OR, 1.845; P = 0.014), prone positioning (OR, 1.793; P = 0.021), transfissural approach (OR, 11.941; P = 0.017), and longer procedure time (OR, 1.036; P = 0.038) were significant predictors of pneumothorax. Multivariate analysis revealed only the transfissural approach (OR, 12.171; P = 0.018) and a longer procedure time (OR, 1.048; P = 0.012) as significant independent predictors. Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occurred, but all complications were minor. A transfissural approach and longer procedure time were significant independent predictors of pneumothorax. Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occur. Complications are usually minor and asymptomatic. A transfissural approach and longer procedure time are significant independent predictors of pneumothorax.
Homogenized boundary conditions and resonance effects in Faraday cages
Hewitt, I. J.
2016-01-01
We present a mathematical study of two-dimensional electrostatic and electromagnetic shielding by a cage of conducting wires (the so-called ‘Faraday cage effect’). Taking the limit as the number of wires in the cage tends to infinity, we use the asymptotic method of multiple scales to derive continuum models for the shielding, involving homogenized boundary conditions on an effective cage boundary. We show how the resulting models depend on key cage parameters such as the size and shape of the wires, and, in the electromagnetic case, on the frequency and polarization of the incident field. In the electromagnetic case, there are resonance effects, whereby at frequencies close to the natural frequencies of the equivalent solid shell, the presence of the cage actually amplifies the incident field, rather than shielding it. By appropriately modifying the continuum model, we calculate the modified resonant frequencies, and their associated peak amplitudes. We discuss applications to radiation containment in microwave ovens and acoustic scattering by perforated shells. PMID:27279775
The wiring diagram of a glomerular olfactory system
Berck, Matthew E; Khandelwal, Avinash; Claus, Lindsey; Hernandez-Nunez, Luis; Si, Guangwei; Tabone, Christopher J; Li, Feng; Truman, James W; Fetter, Rick D; Louis, Matthieu; Samuel, Aravinthan DT; Cardona, Albert
2016-01-01
The sense of smell enables animals to react to long-distance cues according to learned and innate valences. Here, we have mapped with electron microscopy the complete wiring diagram of the Drosophila larval antennal lobe, an olfactory neuropil similar to the vertebrate olfactory bulb. We found a canonical circuit with uniglomerular projection neurons (uPNs) relaying gain-controlled ORN activity to the mushroom body and the lateral horn. A second, parallel circuit with multiglomerular projection neurons (mPNs) and hierarchically connected local neurons (LNs) selectively integrates multiple ORN signals already at the first synapse. LN-LN synaptic connections putatively implement a bistable gain control mechanism that either computes odor saliency through panglomerular inhibition, or allows some glomeruli to respond to faint aversive odors in the presence of strong appetitive odors. This complete wiring diagram will support experimental and theoretical studies towards bridging the gap between circuits and behavior. DOI: http://dx.doi.org/10.7554/eLife.14859.001 PMID:27177418
Programmable growth of branched silicon nanowires using a focused ion beam.
Jun, Kimin; Jacobson, Joseph M
2010-08-11
Although significant progress has been made in being able to spatially define the position of material layers in vapor-liquid-solid (VLS) grown nanowires, less work has been carried out in deterministically defining the positions of nanowire branching points to facilitate more complicated structures beyond simple 1D wires. Work to date has focused on the growth of randomly branched nanowire structures. Here we develop a means for programmably designating nanowire branching points by means of focused ion beam-defined VLS catalytic points. This technique is repeatable without losing fidelity allowing multiple rounds of branching point definition followed by branch growth resulting in complex structures. The single crystal nature of this approach allows us to describe resulting structures with linear combinations of base vectors in three-dimensional (3D) space. Finally, by etching the resulting 3D defined wire structures branched nanotubes were fabricated with interconnected nanochannels inside. We believe that the techniques developed here should comprise a useful tool for extending linear VLS nanowire growth to generalized 3D wire structures.
Homogenized boundary conditions and resonance effects in Faraday cages
NASA Astrophysics Data System (ADS)
Hewett, D. P.; Hewitt, I. J.
2016-05-01
We present a mathematical study of two-dimensional electrostatic and electromagnetic shielding by a cage of conducting wires (the so-called `Faraday cage effect'). Taking the limit as the number of wires in the cage tends to infinity, we use the asymptotic method of multiple scales to derive continuum models for the shielding, involving homogenized boundary conditions on an effective cage boundary. We show how the resulting models depend on key cage parameters such as the size and shape of the wires, and, in the electromagnetic case, on the frequency and polarization of the incident field. In the electromagnetic case, there are resonance effects, whereby at frequencies close to the natural frequencies of the equivalent solid shell, the presence of the cage actually amplifies the incident field, rather than shielding it. By appropriately modifying the continuum model, we calculate the modified resonant frequencies, and their associated peak amplitudes. We discuss applications to radiation containment in microwave ovens and acoustic scattering by perforated shells.
Homogenized boundary conditions and resonance effects in Faraday cages.
Hewett, D P; Hewitt, I J
2016-05-01
We present a mathematical study of two-dimensional electrostatic and electromagnetic shielding by a cage of conducting wires (the so-called 'Faraday cage effect'). Taking the limit as the number of wires in the cage tends to infinity, we use the asymptotic method of multiple scales to derive continuum models for the shielding, involving homogenized boundary conditions on an effective cage boundary. We show how the resulting models depend on key cage parameters such as the size and shape of the wires, and, in the electromagnetic case, on the frequency and polarization of the incident field. In the electromagnetic case, there are resonance effects, whereby at frequencies close to the natural frequencies of the equivalent solid shell, the presence of the cage actually amplifies the incident field, rather than shielding it. By appropriately modifying the continuum model, we calculate the modified resonant frequencies, and their associated peak amplitudes. We discuss applications to radiation containment in microwave ovens and acoustic scattering by perforated shells.
Simpson, Jr, J A
1950-12-05
A multiple wire counter utilizing air at atmospheric pressure as the ionizing medium and having a window of a nylon sheet of less than 0.5 mil thickness coated with graphite. The window is permeable to alpha particles so that the counter is well adapted to surveying sources of alpha radiation.
Integrated Services Digital Network
1992-01-01
users. " Pair Gain • ISDN’s capability to deliver multiple communications channels over a limited set of wires (as in 2B+D service or pasive bus...configuration commands to devices encountered in a communications path, is not yet a reality at Redstone. But for that matter , transparent connectivity
Detecting and removing multiplicative spatial bias in high-throughput screening technologies.
Caraus, Iurie; Mazoure, Bogdan; Nadon, Robert; Makarenkov, Vladimir
2017-10-15
Considerable attention has been paid recently to improve data quality in high-throughput screening (HTS) and high-content screening (HCS) technologies widely used in drug development and chemical toxicity research. However, several environmentally- and procedurally-induced spatial biases in experimental HTS and HCS screens decrease measurement accuracy, leading to increased numbers of false positives and false negatives in hit selection. Although effective bias correction methods and software have been developed over the past decades, almost all of these tools have been designed to reduce the effect of additive bias only. Here, we address the case of multiplicative spatial bias. We introduce three new statistical methods meant to reduce multiplicative spatial bias in screening technologies. We assess the performance of the methods with synthetic and real data affected by multiplicative spatial bias, including comparisons with current bias correction methods. We also describe a wider data correction protocol that integrates methods for removing both assay and plate-specific spatial biases, which can be either additive or multiplicative. The methods for removing multiplicative spatial bias and the data correction protocol are effective in detecting and cleaning experimental data generated by screening technologies. As our protocol is of a general nature, it can be used by researchers analyzing current or next-generation high-throughput screens. The AssayCorrector program, implemented in R, is available on CRAN. makarenkov.vladimir@uqam.ca. Supplementary data are available at Bioinformatics online. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com
A high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen
NASA Astrophysics Data System (ADS)
Luo, ZhiJie; Luo, JianKun; Zhao, WenWen; Cao, Yang; Lin, WeiJie; Zhou, GuoFu
2018-02-01
Electrowetting display technology is realized by tuning the surface energy of a hydrophobic surface by applying a voltage based on electrowetting mechanism. With the rapid development of the electrowetting industry, how to analyze efficiently the quality of an electrowetting display screen has a very important significance. There are two kinds of dead pixels on the electrowetting display screen. One is that the oil of pixel cannot completely cover the display area. The other is that indium tin oxide semiconductor wire connecting pixel and foil was burned. In this paper, we propose a high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen. First, we built an aperture ratio-capacitance model based on the electrical characteristics of electrowetting display. A field-programmable gate array is used as the integrated logic hub of the system for a highly reliable and efficient control of the circuit. Dead pixels can be detected and displayed on a PC-based 2D graphical interface in real time. The proposed dead pixel detection scheme reported in this work has promise in automating electrowetting display experiments.
Two Droplets on Wire Approaching Ignition
NASA Technical Reports Server (NTRS)
2003-01-01
The Fiber-Supported Droplet Combustion (FSDC) uses two droplets positioned on the fiber wire, instead of the usual one. Two droplets more closely simulates the environment in engines, which ignite many fuel droplets at once. The behavior of the burning was also unexpected -- the droplets moved together after ignition, generating quite a bit of data for understanding the interaction of fuel droplets while they burn. This MPEG movie (1.3 MB) shows a time-lapse of this burn (3x speed). Because FSDC is backlit (the bright glow behind the drops), you carnot see the glow of the droplets while they burn -- instead, you see them shrink! The small blobs left on the wire after the burn are the beads used to center the fuel droplet on the wire. This image was taken on STS-94, July 12, 1997, MET:10/19:13 (approximate). FSDC-2 studied fundamental phenomena related to liquid fuel droplet combustion in air. Pure fuels and mixtures of fuels were burned as isolated single and dual droplets with and without forced air convection. The FSDC guest investigator was Forman Williams, University of California, San Diego. The experiment was part of the space research investigations conducted during the Microgravity Science Laboratory-1R mission (STS-94, July 1-17 1997). Advanced combustion experiments will be a part of investigations planned for the International Space Station. (1.3MB, 12-second MPEG, screen 320 x 240 pixels; downlinked video, higher quality not available) A still JPG composite of this movie is available at http://mix.msfc.nasa.gov/ABSTRACTS/MSFC-0300178.html.
Helmy, Tarek A; Sanchez, Carlos E; Bailey, Steven R
2016-03-01
Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries. © 2015 Wiley Periodicals, Inc.
Landing Gear Components Noise Study - PIV and Hot-Wire Measurements
NASA Technical Reports Server (NTRS)
Hutcheson, Florence V.; Burley, Casey L.; Stead, Daniel J.; Becker, Lawrence E.; Price, Jennifer L.
2010-01-01
PIV and hot-wire measurements of the wake flow from rods and bars are presented. The test models include rods of different diameters and cross sections and a rod juxtaposed to a plate. The latter is representative of the latch door that is attached to an aircraft landing gear when the gear is deployed, while the single and multiple rod configurations tested are representative of some of the various struts and cables configuration present on an aircraft landing gear. The test set up is described and the flow measurements are presented. The effect of model surface treatment and freestream turbulence on the spanwise coherence of the vortex shedding is studied for several rod and bar configurations.
Thermal resilient multiple jaw braze fixture
Ney, R.; Perrone, A.J.
1995-07-11
A braze fixture has side walls forming a cavity with an opening to receive a stack of parts to be brazed. Sidewalls of the housing have a plurality of bearing receiving openings into which bearing rods or jaws are inserted to align the stacked elements of the workpiece. The housing can also have view ports to allow a visual check of the alignment. Straps or wires around the fixture are selected to have thermal characteristics similar to the thermal characteristics of the workpiece undergoing brazing. The straps or wires make physical contact with the bearing rods thereby causing bearing rods to maintain the workpiece in proper alignment throughout the entire brazing cycle. 9 figs.
Gamalski, A. D.; Tersoff, J.; Stach, E. A.
2016-04-13
We study the growth of GaN nanowires from liquid Au–Ga catalysts using environmental transmission electron microscopy. GaN wires grow in either (11¯20) or (11¯00) directions, by the addition of {11¯00} double bilayers via step flow with multiple steps. Step-train growth is not typically seen with liquid catalysts, and we suggest that it results from low step mobility related to the unusual double-height step structure. Finally, the results here illustrate the surprising dynamics of catalytic GaN wire growth at the nanoscale and highlight striking differences between the growth of GaN and other III–V semiconductor nanowires.
Grentzer, Jaclyn M; Peipert, Jeffrey F; Zhao, Qiuhong; McNicholas, Colleen; Secura, Gina M; Madden, Tessa
2015-10-01
The objective was to compare three strategies for Chlamydia trachomatis and Neisseria gonorrhoeae screening prior to intrauterine device (IUD) insertion. This was a secondary analysis of the Contraceptive CHOICE Project. We measured the prevalence of C. trachomatis and/or N. gonorrhoeae at the time of IUD insertion. We then compared sensitivity, specificity, negative and positive predictive values, and likelihood ratios for three screening strategies for C. trachomatis and N. gonorrhoeae prior to IUD insertion: (a) "age-based" — age ≤25 years alone; (b) "age/partner-based" — age ≤25 and/or multiple sexual partners; and (c) "risk-based" — age ≤25, multiple sexual partners, inconsistent condom use and/or history of prior sexually transmitted infection (STI). Among 5087 IUD users, 140 (2.8%) tested positive for C. trachomatis, 16 (0.3%) tested positive for N. gonorrhoeae, and 6 (0.1%) were positive for both at the time of IUD insertion. The "risk-based" screening strategy had the highest sensitivity (99.3%) compared to "age-based" and "age/partner-based" screening (80.7% and 84.7%, respectively.) Only one (0.7%) woman with a chlamydia or gonorrhea infection would not have been screened using "risk-based" screening. A risk-based strategy to screen for C. trachomatis and N. gonorrhoeae prior to IUD insertion has higher sensitivity than screening based on age alone or age and multiple sexual partners. Using a risk-based screening strategy (age≤25, multiple sexual partners, inconsistent condom use and/or history of an STI) to determine who should be screened for C. trachomatis and N. gonorrhoeae prior to IUD insertion will miss very few cases of infection and obviates the need for universal screening. Copyright © 2015 Elsevier Inc. All rights reserved.
The FLIGHT Drosophila RNAi database
Bursteinas, Borisas; Jain, Ekta; Gao, Qiong; Baum, Buzz; Zvelebil, Marketa
2010-01-01
FLIGHT (http://flight.icr.ac.uk/) is an online resource compiling data from high-throughput Drosophila in vivo and in vitro RNAi screens. FLIGHT includes details of RNAi reagents and their predicted off-target effects, alongside RNAi screen hits, scores and phenotypes, including images from high-content screens. The latest release of FLIGHT is designed to enable users to upload, analyze, integrate and share their own RNAi screens. Users can perform multiple normalizations, view quality control plots, detect and assign screen hits and compare hits from multiple screens using a variety of methods including hierarchical clustering. FLIGHT integrates RNAi screen data with microarray gene expression as well as genomic annotations and genetic/physical interaction datasets to provide a single interface for RNAi screen analysis and datamining in Drosophila. PMID:20855970
PPM-based System for Guided Waves Communication Through Corrosion Resistant Multi-wire Cables
NASA Astrophysics Data System (ADS)
Trane, G.; Mijarez, R.; Guevara, R.; Pascacio, D.
Novel wireless communication channels are a necessity in applications surrounded by harsh environments, for instance down-hole oil reservoirs. Traditional radio frequency (RF) communication schemes are not capable of transmitting signals through metal enclosures surrounded by corrosive gases and liquids. As an alternative to RF, a pulse position modulation (PPM) guided waves communication system has been developed and evaluated using a corrosion resistant 4H18 multi-wire cable, commonly used to descend electronic gauges in down-hole oil applications, as the communication medium. The system consists of a transmitter and a receiver that utilizes a PZT crystal, for electrical/mechanical coupling, attached to each extreme of the multi-wire cable. The modulator is based on a microcontroller, which transmits60 kHz guided wave pulses, and the demodulator is based on a commercial digital signal processor (DSP) module that performs real time DSP algorithms. Experimental results are presented, which were obtained using a 1m corrosion resistant 4H18multi-wire cable, commonly used with downhole electronic gauges in the oil sector. Although there was significant dispersion and multiple mode excitations of the transmitted guided wave energy pulses, the results show that data rates on the order of 500 bits per second are readily available employing PPM and simple communications techniques.
Simple debugging techniques for embedded subsystems
NASA Astrophysics Data System (ADS)
MacPherson, Matthew S.; Martin, Kevin S.
1990-08-01
This paper describes some of the tools and methods used for developing and debugging embedded subsystems at Fermilab. Specifically, these tools have been used for the Flying Wire project and are currently being employed for the New TECAR upgrade. The Flying Wire is a subsystem that swings a wire through the beam in order to measure luminosity and beam density distribution, and TECAR (Tevatron excitation controller and regulator) controls the power-supply ramp generation for the superconducting Tevatron accelerator at Fermilab. In both instances the subsystem hardware consists of a VME crate with one or more processors, shared memory and a network connection to the accelerator control system. Two real-time-operating systems are currently being used: VRTX for the Flying Wire system, and MTOS for New TECAR. The code which runs in these subsystems is a combination of C and assembler and is developed using the Microtec cross-development tools on a VAX 8650 running VMS. This paper explains how multiple debuggers are used to give the greatest possible flexibility from assembly to high-level debugging. Also discussed is how network debugging and network downloading can make a very effective and efficient means of finding bugs in the subsystem environment. The debuggers used are PROBE1, TRACER and the MTOS debugger.
Economic consequences of earthquakes: bridging research and practice with HayWired
NASA Astrophysics Data System (ADS)
Wein, A. M.; Kroll, C.
2016-12-01
The U.S. Geological Survey partners with organizations and experts to develop multiple hazard scenarios. The HayWired earthquake scenario refers to a rupture of the Hayward fault in the Bay Area of California and addresses the potential chaos related to interconnectedness at many levels: the fault afterslip and aftershocks, interdependencies of lifelines, wired/wireless technology, communities at risk, and ripple effects throughout today's digital economy. The scenario is intended for diverse audiences. HayWired analyses translate earthquake hazards (surface rupture, ground shaking, liquefaction, landslides) into physical engineering and environmental health impacts, and into societal consequences. Damages to life and property and lifeline service disruptions are direct causes of business interruption. Economic models are used to estimate the economic impacts and resilience in the regional economy. The objective of the economic analysis is to inform policy discourse about economic resilience at all three levels of the economy: macro, meso, and micro. Stakeholders include businesses, economic development, and community leaders. Previous scenario analyses indicate the size of an event: large earthquakes and large winter storms are both "big ones" for California. They motivate actions to reduce the losses from fire following earthquake and water supply outages. They show the effect that resilience can have on reducing economic losses. Evaluators find that stakeholders learned the most about the economic consequences.
Surface characterization of nickel titanium orthodontic arch wires
Krishnan, Manu; Seema, Saraswathy; Tiwari, Brijesh; Sharma, Himanshu S.; Londhe, Sanjay; Arora, Vimal
2015-01-01
Background Surface roughness of nickel titanium orthodontic arch wires poses several clinical challenges. Surface modification with aesthetic/metallic/non metallic materials is therefore a recent innovation, with clinical efficacy yet to be comprehensively evaluated. Methods One conventional and five types of surface modified nickel titanium arch wires were surface characterized with scanning electron microscopy, energy dispersive analysis, Raman spectroscopy, Atomic force microscopy and 3D profilometry. Root mean square roughness values were analyzed by one way analysis of variance and post hoc Duncan's multiple range tests. Results Study groups demonstrated considerable reduction in roughness values from conventional in a material specific pattern: Group I; conventional (578.56 nm) > Group V; Teflon (365.33 nm) > Group III; nitride (301.51 nm) > Group VI (i); rhodium (290.64 nm) > Group VI (ii); silver (252.22 nm) > Group IV; titanium (229.51 nm) > Group II; resin (158.60 nm). It also showed the defects with aesthetic (resin/Teflon) and nitride surfaces and smooth topography achieved with metals; titanium/silver/rhodium. Conclusions Resin, Teflon, titanium, silver, rhodium and nitrides were effective in decreasing surface roughness of nickel titanium arch wires albeit; certain flaws. Findings have clinical implications, considering their potential in lessening biofilm adhesion, reducing friction, improving corrosion resistance and preventing nickel leach and allergic reactions. PMID:26843749
Using Ant Colony Optimization for Routing in VLSI Chips
NASA Astrophysics Data System (ADS)
Arora, Tamanna; Moses, Melanie
2009-04-01
Rapid advances in VLSI technology have increased the number of transistors that fit on a single chip to about two billion. A frequent problem in the design of such high performance and high density VLSI layouts is that of routing wires that connect such large numbers of components. Most wire-routing problems are computationally hard. The quality of any routing algorithm is judged by the extent to which it satisfies routing constraints and design objectives. Some of the broader design objectives include minimizing total routed wire length, and minimizing total capacitance induced in the chip, both of which serve to minimize power consumed by the chip. Ant Colony Optimization algorithms (ACO) provide a multi-agent framework for combinatorial optimization by combining memory, stochastic decision and strategies of collective and distributed learning by ant-like agents. This paper applies ACO to the NP-hard problem of finding optimal routes for interconnect routing on VLSI chips. The constraints on interconnect routing are used by ants as heuristics which guide their search process. We found that ACO algorithms were able to successfully incorporate multiple constraints and route interconnects on suite of benchmark chips. On an average, the algorithm routed with total wire length 5.5% less than other established routing algorithms.
Preliminary experimental results of tungsten wire-array Z-pinches on primary test stand
NASA Astrophysics Data System (ADS)
Huang, Xian-Bin; Zhou, Shao-Tong; Dan, Jia-Kun; Ren, Xiao-Dong; Wang, Kun-Lun; Zhang, Si-Qun; Li, Jing; Xu, Qiang; Cai, Hong-Chun; Duan, Shu-Chao; Ouyang, Kai; Chen, Guang-Hua; Ji, Ce; Wei, Bing; Feng, Shu-Ping; Wang, Meng; Xie, Wei-Ping; Deng, Jian-Jun; Zhou, Xiu-Wen; Yang, Yi
2015-07-01
The Primary Test Stand (PTS) developed at the China Academy of Engineering Physics is a 20 TW pulsed power driver, which can deliver a ˜10 MA, 70 ns rise-time (10%-90%) current to a short-circuit load and has important applications in Z-pinch driven inertial confinement fusion and high energy density physics. Preliminary results of tungsten wire-array Z-pinch experiments on PTS are presented. The load geometries investigated include 15-mm-tall cylindrical single and nested arrays with diameter ranging from 13 mm to 30 mm, consisting of 132-300 tungsten wires with 5-10 μm in diameter. Multiple diagnostics were fielded to characterize the x-ray radiation from wire-array Z pinches. The x-ray peak power (˜50 TW) and total radiated energy (˜500 kJ) were obtained from a single 20-mm-diam array with 80-ns stagnation time. The highest x-ray peak power up to 80 TW with 2.4 ns FWHM was achieved by using a nested array with 20-mm outer diameter, and the total x-ray energy from the nested array is comparable to that of single array. Implosion velocity estimated from the time-resolved image measurement exceeds 30 cm/μs. The detailed experimental results and other findings are presented and discussed.
ERIC Educational Resources Information Center
Emery, Jill
2010-01-01
In August 2010, "Wired" magazine declared, "The Web is Dead. Long Live the Internet." Citing the rise of IPad & Smartphone sales and the rapid explosion of application-based software to run various programs on multiple computing devices--but especially mobile computing devices--people spend more hours than ever connected to or "on" the Internet…
Investigation of the Multiple Method Adaptive Control (MMAC) method for flight control systems
NASA Technical Reports Server (NTRS)
Athans, M.; Baram, Y.; Castanon, D.; Dunn, K. P.; Green, C. S.; Lee, W. H.; Sandell, N. R., Jr.; Willsky, A. S.
1979-01-01
The stochastic adaptive control of the NASA F-8C digital-fly-by-wire aircraft using the multiple model adaptive control (MMAC) method is presented. The selection of the performance criteria for the lateral and the longitudinal dynamics, the design of the Kalman filters for different operating conditions, the identification algorithm associated with the MMAC method, the control system design, and simulation results obtained using the real time simulator of the F-8 aircraft at the NASA Langley Research Center are discussed.
Duncan, David B.
1992-01-01
An improved wick for a metal vapor laser is made of a refractory metal cylinder, preferably molybdenum or tungsten for a copper laser, which provides the wicking surface. Alternately, the inside surface of the ceramic laser tube can be metalized to form the wicking surface. Capillary action is enhanced by using wire screen, porous foam metal, or grooved surfaces. Graphite or carbon, in the form of chunks, strips, fibers or particles, is placed on the inside surface of the wick to reduce water, reduce metal oxides and form metal carbides.
Procedures for precap visual inspection
NASA Technical Reports Server (NTRS)
1984-01-01
Screening procedures for the final precap visual inspection of microcircuits used in electronic system components are described as an aid in training personnel unfamiliar with microcircuits. Processing techniques used in industry for the manufacture of monolithic and hybrid components are presented and imperfections that may be encountered during this inspection are discussed. Problem areas such as scratches, voids, adhesions, and wire bonding are illustrated by photomicrographs. This guide can serve as an effective tool in training personnel to perform precap visual inspections efficiently and reliably.
NASA Astrophysics Data System (ADS)
Zhang, Luhui; Shi, Enzheng; Ji, Chunyan; Li, Zhen; Li, Peixu; Shang, Yuanyuan; Li, Yibin; Wei, Jinquan; Wang, Kunlin; Zhu, Hongwei; Wu, Dehai; Cao, Anyuan
2012-07-01
Electrode materials are key components for fiber solar cells, and when combined with active layers (for light absorption and charge generation) in appropriate ways, they enable design and fabrication of efficient and innovative device structures. Here, we apply carbon nanotube yarns as counter electrodes in combination with CdSe nanowire-grafted primary electrodes (Ti wire) for making fiber and fabric-shaped photoelectrochemical cells with power conversion efficiencies in the range 1% to 2.9%. The spun-twist long nanotube yarns possess both good electrical conductivity and mechanical flexibility compared to conventional metal wires or carbon fibers, which facilitate fabrication of solar cells with versatile configurations. A unique feature of our process is that instead of making individual fiber cells, we directly weave single or multiple nanotube yarns with primary electrodes into a functional fabric. Our results demonstrate promising applications of semiconducting nanowires and carbon nanotubes in woven photovoltaics.Electrode materials are key components for fiber solar cells, and when combined with active layers (for light absorption and charge generation) in appropriate ways, they enable design and fabrication of efficient and innovative device structures. Here, we apply carbon nanotube yarns as counter electrodes in combination with CdSe nanowire-grafted primary electrodes (Ti wire) for making fiber and fabric-shaped photoelectrochemical cells with power conversion efficiencies in the range 1% to 2.9%. The spun-twist long nanotube yarns possess both good electrical conductivity and mechanical flexibility compared to conventional metal wires or carbon fibers, which facilitate fabrication of solar cells with versatile configurations. A unique feature of our process is that instead of making individual fiber cells, we directly weave single or multiple nanotube yarns with primary electrodes into a functional fabric. Our results demonstrate promising applications of semiconducting nanowires and carbon nanotubes in woven photovoltaics. Electronic supplementary information (ESI) available. See DOI: 10.1039/c2nr31440a
High-throughput screening for combinatorial thin-film library of thermoelectric materials.
Watanabe, Masaki; Kita, Takuji; Fukumura, Tomoteru; Ohtomo, Akira; Ueno, Kazunori; Kawasaki, Masashi
2008-01-01
A high-throughput method has been developed to evaluate the Seebeck coefficient and electrical resistivity of combinatorial thin-film libraries of thermoelectric materials from room temperature to 673 K. Thin-film samples several millimeters in size were deposited on an integrated Al2O3 substrate with embedded lead wires and local heaters for measurement of the thermopower under a controlled temperature gradient. An infrared camera was used for real-time observation of the temperature difference Delta T between two electrical contacts on the sample to obtain the Seebeck coefficient. The Seebeck coefficient and electrical resistivity of constantan thin films were shown to be almost identical to standard data for bulk constantan. High-throughput screening was demonstrated for a thermoelectric Mg-Si-Ge combinatorial library.
Yuenyongviwat, Varah; Tuntarattanapong, Pakjai; Tangtrakulwanich, Boonsin
2016-01-11
Internal fixation is one treatment for femoral neck fracture. Some devices and techniques reported improved accuracy and decreased fluoroscopic time. However, these are not widely used nowadays due to the lack of available special instruments and techniques. To improve the surgical procedure, the authors designed a new adjustable drill guide and tested the efficacy of the device. The authors developed a new adjustable drill guide for cannulated screw guide wire insertion for multiple screw fixation. Eight orthopaedic surgeons performed the experimental study to evaluate the efficacy of this device. Each surgeon performed guide wire insertion for multiple screw fixation in six synthetic femurs: three times with the new device and three times with the conventional technique. The fluoroscopic time, operative time and surgeon satisfaction were evaluated. In the operations with the new adjustable drill guide, the fluoroscopic and operative times were significantly lower than the operations with the conventional technique (p < 0.05). The mean score for the level of satisfaction of this device was also statistically significantly better (p = 0.02) than the conventional technique. The fluoroscopic and operative times with the new adjustable drill guide were reduced for multiple screw fixation of femoral neck fracture and the satisfaction of the surgeons was good.
van Dijk, J P; Eiglsperger, U; Hellmann, D; Giannakopoulos, N N; McGill, K C; Schindler, H J; Lapatki, B G
2016-09-01
To study motor unit activity in the medio-lateral extension of the masseter using an adapted scanning EMG technique that allows studying the territories of multiple motor units (MUs) in one scan. We studied the m. masseter of 10 healthy volunteers in whom two scans were performed. A monopolar scanning needle and two pairs of fine-wire electrodes were inserted into the belly of the muscle. The signals of the fine wire electrodes were decomposed into the contribution of single MUs and used as a trigger for the scanning needle. In this manner multiple MU territory scans were obtained simultaneously. We determined 161 MU territories. The maximum number of territories obtained in one scan was 15. The median territory size was 4.0mm. Larger and smaller MU territories were found throughout the muscle. The presented technique showed its feasibility in obtaining multiple MU territories in one scan. MUs were active throughout the depth of the muscle. The distribution of electrical and anatomical size of MUs substantiates the heterogeneous distribution of MUs throughout the muscle volume. This distributed activity may be of functional significance for the stabilization of the muscle during force generation. Copyright © 2016 International Federation of Clinical Neurophysiology. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Xiaorong; Caspi, Shlomo; Dietderich, Daniel R.; Ghiorso, William B.; Gourlay, Stephen A.; Higley, Hugh C.; Lin, Andy; Prestemon, Soren O.; van der Laan, Danko; Weiss, Jeremy D.
2018-04-01
REBCO coated conductors maintain a high engineering current density above 16 T at 4.2 K. That fact will significantly impact markets of various magnet applications including high-field magnets for high-energy physics and fusion reactors. One of the main challenges for the high-field accelerator magnet is the use of multi-tape REBCO cables with high engineering current density in magnet development. Several approaches developing high-field accelerator magnets using REBCO cables are demonstrated. In this paper, we introduce an alternative concept based on the canted cos θ (CCT) magnet design using conductor on round core (CORC®) wires that are wound from multiple REBCO tapes with a Cu core. We report the development and test of double-layer three-turn CCT dipole magnets using CORC® wires at 77 and 4.2 K. The scalability of the CCT design allowed us to effectively develop and demonstrate important magnet technology features such as coil design, winding, joints and testing with minimum conductor lengths. The test results showed that the CCT dipole magnet using CORC® wires was a viable option in developing a REBCO accelerator magnet. One of the critical development needs is to increase the engineering current density of the 3.7 mm diameter CORC® wire to 540 A mm-2 at 21 T, 4.2 K and to reduce the bending radius to 15 mm. This would enable a compact REBCO dipole insert magnet to generate a 5 T field in a background field of 16 T at 4.2 K.
Kaur, Sandeep; Harjai, Kusum; Chhibber, Sanjay
2016-01-01
Staphylococcus comprises up to two-thirds of all pathogens in orthopaedic implant infections with two species respectively Staphylococcus aureus and Staphylococcus epidermidis, being the predominate etiological agents isolated. Further, with the emergence of methicillin-resistant S. aureus (MRSA), treatment of S. aureus implant infections has become more difficult, thus representing a devastating complication. Use of local delivery system consisting of S.aureus specific phage along with linezolid (incorporated in biopolymer) allowing gradual release of the two agents at the implant site represents a new, still unexplored treatment option (against orthopaedic implant infections) that has been studied in an animal model of prosthetic joint infection. Naked wire, hydroxypropyl methylcellulose (HPMC) coated wire and phage and /or linezolid coated K-wire were surgically implanted into the intra-medullary canal of mouse femur bone of respective groups followed by inoculation of S.aureus ATCC 43300(MRSA). Mice implanted with K-wire coated with both the agents i.e phage as well as linezolid (dual coated wires) showed maximum reduction in bacterial adherence, associated inflammation of the joint as well as faster resumption of locomotion and motor function of the limb. Also, all the coating treatments showed no emergence of resistant mutants. Use of dual coated implants incorporating lytic phage (capable of self-multiplication) as well as linezolid presents an attractive and aggressive early approach in preventing as well as treating implant associated infections caused by methicillin resistant S. aureus strains as assessed in a murine model of experimental joint infection. PMID:27333300
Automated macromolecular crystallization screening
Segelke, Brent W.; Rupp, Bernhard; Krupka, Heike I.
2005-03-01
An automated macromolecular crystallization screening system wherein a multiplicity of reagent mixes are produced. A multiplicity of analysis plates is produced utilizing the reagent mixes combined with a sample. The analysis plates are incubated to promote growth of crystals. Images of the crystals are made. The images are analyzed with regard to suitability of the crystals for analysis by x-ray crystallography. A design of reagent mixes is produced based upon the expected suitability of the crystals for analysis by x-ray crystallography. A second multiplicity of mixes of the reagent components is produced utilizing the design and a second multiplicity of reagent mixes is used for a second round of automated macromolecular crystallization screening. In one embodiment the multiplicity of reagent mixes are produced by a random selection of reagent components.
Pierce, Jim D.
1994-01-01
A container for hazardous materials capable of protecting the enclosed materials from high speed impact. Energy absorption is provided by a multiplicity of crushable layers of either wire mesh or perforated metal sheets which thin and flow together under impact loading. Layers of a higher tensile strength material are interspersed within the crushable layers to confine them and increase performance.
Energy requirement for the production of silicon solar arrays
NASA Technical Reports Server (NTRS)
Lindmayer, J.; Wihl, M.; Scheinine, A.; Morrison, A.
1977-01-01
An assessment of potential changes and alternative technologies which could impact the photovoltaic manufacturing process is presented. Topics discussed include: a multiple wire saw, ribbon growth techniques, silicon casting, and a computer model for a large-scale solar power plant. Emphasis is placed on reducing the energy demands of the manufacturing process.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-13
... Unusual Design Features The GVI will have a fly-by-wire electronic flight control system. This system... the design of the flight control system has multiple modes of operation, a means must be provided to... Control System Mode Annunciation AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of...
Creating Technology Infrastructures in a Rural School District: A Partnership Approach.
ERIC Educational Resources Information Center
Jensen, Dennis
Rural schools face significant challenges in upgrading their technology infrastructures. Rural school districts tend to have older school buildings that have multiple problems and lack climate control, adequate space, and necessary wiring. In rural districts, it may be difficult to find the leadership and expertise needed to provide professional…
Lightweight, Wearable, Metal Rubber Sensor
NASA Technical Reports Server (NTRS)
Hill, Andrea
2015-01-01
For autonomous health monitoring. NanoSonic, Inc., has developed comfortable garments with multiple integrated sensors designed to monitor astronaut health throughout long-duration space missions. The combined high electrical conductivity, low mechanical modulus, and environmental robustness of the sensors make them an effective, lightweight, and comfortable alternative to conventional use of metal wiring and cabling.
NASA Astrophysics Data System (ADS)
Varun, Sajja; Reddy, Kalakada Bhargav Bal; Vardhan Reddy, R. R. Vishnu
2016-09-01
In this research work, development of a multi response optimization technique has been undertaken, using traditional desirability analysis and non-traditional particle swarm optimization techniques (for different customer's priorities) in wire electrical discharge machining (WEDM). Monel 400 has been selected as work material for experimentation. The effect of key process parameters such as pulse on time (TON), pulse off time (TOFF), peak current (IP), wire feed (WF) were on material removal rate (MRR) and surface roughness(SR) in WEDM operation were investigated. Further, the responses such as MRR and SR were modelled empirically through regression analysis. The developed models can be used by the machinists to predict the MRR and SR over a wide range of input parameters. The optimization of multiple responses has been done for satisfying the priorities of multiple users by using Taguchi-desirability function method and particle swarm optimization technique. The analysis of variance (ANOVA) is also applied to investigate the effect of influential parameters. Finally, the confirmation experiments were conducted for the optimal set of machining parameters, and the betterment has been proved.
Wang, Long; Liu, Yong; Yin, Zengshan
2018-01-01
To achieve launch-on-demand for Operationally Responsive Space (ORS) missions, in this article, an intra-satellite wireless network (ISWN) is presented. It provides a wireless and modularized scheme for intra-spacecraft sensing and data buses. By removing the wired data bus, the commercial off-the-shelf (COTS) based wireless modular architecture will reduce both the volume and weight of the satellite platform, thus achieving rapid design and cost savings in development and launching. Based on the on-orbit data demand analysis, a hybrid time division multiple access/carrier sense multiple access (TDMA/CSMA) protocol is proposed. It includes an improved clear channel assessment (CCA) mechanism and a traffic adaptive slot allocation method. To analyze the access process, a Markov model is constructed. Then a detailed calculation is given in which the unsaturated cases are considered. Through simulations, the proposed protocol is proved to commendably satisfy the demands and performs better than existing schemes. It helps to build a full-wireless satellite instead of the current wired ones, and will contribute to provide dynamic space capabilities for ORS missions. PMID:29757243
Wang, Long; Liu, Yong; Yin, Zengshan
2018-05-12
To achieve launch-on-demand for Operationally Responsive Space (ORS) missions, in this article, an intra-satellite wireless network (ISWN) is presented. It provides a wireless and modularized scheme for intra-spacecraft sensing and data buses. By removing the wired data bus, the commercial off-the-shelf (COTS) based wireless modular architecture will reduce both the volume and weight of the satellite platform, thus achieving rapid design and cost savings in development and launching. Based on the on-orbit data demand analysis, a hybrid time division multiple access/carrier sense multiple access (TDMA/CSMA) protocol is proposed. It includes an improved clear channel assessment (CCA) mechanism and a traffic adaptive slot allocation method. To analyze the access process, a Markov model is constructed. Then a detailed calculation is given in which the unsaturated cases are considered. Through simulations, the proposed protocol is proved to commendably satisfy the demands and performs better than existing schemes. It helps to build a full-wireless satellite instead of the current wired ones, and will contribute to provide dynamic space capabilities for ORS missions.
High-frequency ultrasonic wire bonding systems
Tsujino; Yoshihara; Sano; Ihara
2000-03-01
The vibration characteristics of longitudinal-complex transverse vibration systems with multiple resonance frequencies of 350-980 kHz for ultrasonic wire bonding of IC, LSI or electronic devices were studied. The complex vibration systems can be applied for direct welding of semiconductor tips (face-down bonding, flip-chip bonding) and packaging of electronic devices. A longitudinal-complex transverse vibration bonding system consists of a complex transverse vibration rod, two driving longitudinal transducers 7.0 mm in diameter and a transverse vibration welding tip. The vibration distributions along ceramic and stainless-steel welding tips were measured at up to 980 kHz. A high-frequency vibration system with a height of 20.7 mm and a weight of less than 15 g was obtained.
An Optical Actuation System and Curvature Sensor for a MR-compatible Active Needle
Ryu, Seok Chang; Quek, Zhan Fan; Renaud, Pierre; Black, Richard J.; Daniel, Bruce L.; Cutkosky, Mark R.
2015-01-01
A side optical actuation method is presented for a slender MR-compatible active needle. The needle includes an active region with a shape memory alloy (SMA) wire actuator, where the wire generates a contraction force when optically heated by a laser delivered though optical fibers, producing needle tip bending. A prototype, with multiple side heating spots, demonstrates twice as fast an initial response compared to fiber tip heating when 0.8 W of optical power is applied. A single-ended optical sensor with a gold reflector is also presented to measure the curvature as a function of optical transmission loss. Preliminary tests with the sensor prototype demonstrate approximately linear response and a repeatable signal, independent of the bending history. PMID:26509099
Accelerated aging test results for aerospace wire insulation constructions
NASA Technical Reports Server (NTRS)
Dunbar, William G.
1995-01-01
Several wire insulation constructions were evaluated with and without continuous glow discharges at low pressure and high temperature to determine the aging characteristics of acceptable wire insulation constructions. It was known at the beginning of the test program that insulation aging takes several years when operated at normal ambient temperature and pressure of 20 C and 760 torr. Likewise, it was known that the accelerated aging process decreases insulation life by approximately 50% for each 10 C temperature rise. Therefore, the first phases of the program, not reported in these test results, were to select wire insulation constructions that could operate at high temperature and low pressure for over 10,000 hours with negligible shrinkage and little materials' deterioration.The final phase of the program was to determine accelerated aging characteristics. When an insulation construction is subjected to partial discharges the insulation is locally heated by the bombardment of the discharges, the insulation is also subjected to ozone and other deteriorating gas particles that may significantly increase the aging process. Several insulation systems using either a single material or combinations of teflon, kapton, and glass insulation constructions were tested. All constructions were rated to be partial discharge and/or corona-free at 240 volts, 400 Hz and 260 C (500 F) for 50, 000 hours at altitudes equivalent to the Paschen law. Minimum partial discharge aging tests were preceded by screening tests lasting 20 hours at 260 C. The aging process was accelerated by subjecting the test articles to temperatures up to 370 C (700 F) with and without partial discharges. After one month operation with continuous glow discharges surrounding the test articles, most insulation systems were either destroyed or became brittle, cracked, and unsafe for use. Time with space radiation as with partial discharges is accumulative.
Paper-based maskless enzymatic sensor for glucose determination combining ink and wire electrodes.
Amor-Gutiérrez, O; Costa Rama, E; Costa-García, A; Fernández-Abedul, M T
2017-07-15
In this work we have developed an amperometric enzymatic biosensor in a paper-based platform with a mixed electrode configuration: carbon ink for the working electrode (WE) and metal wires (from a low-cost standard electronic connection) for reference (RE) and auxiliary electrodes (AE). A hydrophobic wax-defined paper area was impregnated with diluted carbon ink. Three gold-plated pins of the standard connection are employed, one for connecting the WE and the other two acting as RE and AE. The standard connection works as a clip in order to support the paper in between. As a proof-of-concept, glucose sensing was evaluated. The enzyme cocktail (glucose oxidase, horseradish peroxidase and potassium ferrocyanide as mediator of the electron transfer) was adsorbed on the surface. After drying, glucose solution was added to the paper, on the opposite side of the carbon ink. It wets RE and AE, and flows by capillarity through the paper contacting the carbon WE surface. The reduction current of ferricyanide, product of the enzymatic reaction, is measured chronoamperometrically and correlates to the concentration of glucose. Different parameters related to the bioassay were optimized, adhering the piece of paper onto a conventional screen-printed carbon electrode (SPCE). In this way, the RE and the AE of the commercial card were employed for optimizing the paper-WE. After evaluating the assay system in the hybrid paper-SPCE cell, the three-electrode system consisting of paper-WE, wire-RE and wire-AE, was employed for glucose determination, achieving a linear range between 0.3 and 15mM with good analytical features and being able of quantifying glucose in real food samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Accelerated aging test results for aerospace wire insulation constructions
NASA Astrophysics Data System (ADS)
Dunbar, William G.
1995-11-01
Several wire insulation constructions were evaluated with and without continuous glow discharges at low pressure and high temperature to determine the aging characteristics of acceptable wire insulation constructions. It was known at the beginning of the test program that insulation aging takes several years when operated at normal ambient temperature and pressure of 20 C and 760 torr. Likewise, it was known that the accelerated aging process decreases insulation life by approximately 50% for each 10 C temperature rise. Therefore, the first phases of the program, not reported in these test results, were to select wire insulation constructions that could operate at high temperature and low pressure for over 10,000 hours with negligible shrinkage and little materials' deterioration.The final phase of the program was to determine accelerated aging characteristics. When an insulation construction is subjected to partial discharges the insulation is locally heated by the bombardment of the discharges, the insulation is also subjected to ozone and other deteriorating gas particles that may significantly increase the aging process. Several insulation systems using either a single material or combinations of teflon, kapton, and glass insulation constructions were tested. All constructions were rated to be partial discharge and/or corona-free at 240 volts, 400 Hz and 260 C (500 F) for 50, 000 hours at altitudes equivalent to the Paschen law. Minimum partial discharge aging tests were preceded by screening tests lasting 20 hours at 260 C. The aging process was accelerated by subjecting the test articles to temperatures up to 370 C (700 F) with and without partial discharges. After one month operation with continuous glow discharges surrounding the test articles, most insulation systems were either destroyed or became brittle, cracked, and unsafe for use. Time with space radiation as with partial discharges is accumulative.
McKeever, P E; Wahl, R L; Shakui, P; Jackson, G A; Letica, L H; Liebert, M; Taren, J A; Beierwaltes, W H; Hoff, J T
1990-06-01
To test the feasibility of primary screening of hybridoma supernatants against human glioma tissue, over 5000 combinations of hybridoma supernatants with glioma tissue, cultured glioma cells, and normal central neural tissue were screened with a new multiple-well (M-well) screening system. This is an immunoperoxidase assay system with visual endpoints for screening 20-30 hybridoma supernatants per single microscope slide. There were extensive differences between specificities to tissue and to cultured glioma cells when both were screened with M-wells and when cultured cells were screened with standard semi-automated fluorescence. Primary M-well screening with glioma tissue detected seven hybridoma supernatants that specifically identified parenchymal cells of glioma tissue and that were not detected with cultured cells. Immunoreactivities of individual supernatants for vascular components (nine supernatants), necrosis (five supernatants), and nuclei (three supernatants) were detected. Other supernatants bound multiple sites on glioma tissue and/or subpopulations of neurons and glia of normal tissue. The results show that primary screening with glioma tissue detects a number of different specificities of hybridoma supernatants to gliomas not detected by conventional screening with cultured cells. These are potentially applicable to diagnosis and therapy.
Langhans, Linnea; Jensen, Maj-Britt; Talman, Maj-Lis M; Vejborg, Ilse; Kroman, Niels; Tvedskov, Tove F
2017-04-01
New techniques for preoperative localization of nonpalpable breast lesions may decrease the reoperation rate in breast-conserving surgery (BCS) compared with rates after surgery with the standard wire-guided localization. However, a valid reoperation rate for this procedure needs to be established for comparison, as previous studies on this procedure include a variety of malignant and benign breast lesions. To determine the reoperation rate after wire-guided BCS in patients with histologically verified nonpalpable invasive breast cancer (IBC) or ductal carcinoma in situ (DCIS) and to examine whether the risk of reoperation is associated with DCIS or histologic type of the IBC. This nationwide study including women with histologically verified IBC or DCIS having wire-guided BCS performed between January 1, 2010, and December 31, 2013, used data from the Danish National Patient Registry that were cross-checked with the Danish Breast Cancer Group database and the Danish Pathology Register. Reoperation rate after wire-guided BCS in patients with IBC or DCIS. Wire-guided BCS was performed in 4118 women (mean [SD] age, 60.9 [8.7] years). A total of 725 patients (17.6%) underwent a reoperation: 593 were reexcisions (14.4%) and 132 were mastectomies (3.2%). Significantly more patients with DCIS (271 of 727 [37.3%]) than with IBC (454 of 3391 [13.4%]) underwent a reoperation (adjusted odds ratio, 3.82; 95% CI, 3.19-4.58; P < .001). After the first reexcision, positive margins were still present in 97 patients (16.4%). The risk of repeated positive margins was significantly higher in patients with DCIS vs those with IBC (unadjusted odds ratio, 2.21; 95% CI, 1.42-3.43; P < .001). The risk of reoperation was significantly increased in patients with lobular carcinoma vs those with ductal carcinoma (adjusted odds ratio, 1.44; 95% CI 1.06-1.95; P = .02). A total of 202 patients (4.9%) had a subsequent completion mastectomy, but no difference was found in the type of reoperation between patients with DCIS and those with IBC. A lower reoperation rate after wire-guided BCS was found in this study than those shown in previous studies. However, the risk of reoperation in patients with DCIS was 3 times higher than in those with IBC. The widespread use of mammographic screening will increase the number of patients diagnosed with DCIS, making a precise localization of nonpalpable DCIS lesions even more important.
Continuous measurements of bronchial exposure induced by radon decay products during inhalation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iwaoka, Kazuki; Tokonami, Shinji; Yonehara, Hidenori
2007-09-15
The deposition of radon decay products is not equal in each of the respiratory regions and as the presence of radon has been linked with an increase in lung cancer risk, it is important to calculate the deposition of radon decay products in each of the respiratory regions. Recently, many studies on the deposition of radon in respiratory regions have been simulated using wire screens. The systems and equipment used in those studies are not suitable for field measurements as their dimensions are relatively massive, nor can they measure continuously. We developed a continuous bronchial dosimeter (CBD) which is suitablemore » for field measurements. It was designed with specifications that allow it to be remain compact. The CBD simulates the deposition of radon decay products in the different respiratory regions by the use of a combination of wire screens. Deposition in the simulated regions of the lung can be continuously estimated in various environments. The ratio of activities deposited in a simulated nasal cavity (N) and tracheobronchial (TB) regions was calculated from the results of simultaneous measurements using CBD-R (reference), CBD-N (nasal), and CBD-TB (tracheobronchial) measurement units. After aerosols were injected into the radon chamber, the ratio of N and TB depositions decreased. This results indicate that the CBD gave a good response to changes in the environment. It was found that the ratio of N and TB deposition also varied with time in each actual environment.« less
Wang, Lei; Bock, David C.; Li, Jing; ...
2018-02-20
Here, a series of one-dimensional CuFe 2O 4 nano/sub-micron wires possessing different diameters, crystal phases, and crystal sizes have been successfully generated using a facile template-assisted co precipitation reaction at room temperature, followed by a short post-annealing process. The diameter and the crystal structure of the resulting CuFe 2O4 (CFO) wires were judiciously tuned by varying the pore size of the template and the post-annealing temperature, respectively. Carbon nanotubes (CNTs) were incorporated to generate CFO-CNT binder-free anodes, and multiple characterization techniques were employed with the goal of delineating the relationships between electrochemical behavior and the properties of both the CFOmore » wires (crystal phase, wire diameter, crystal size) and the electrode architecture (binder-free vs. conventionally prepared approaches). The study reveals several notable findings. First, the crystal phase (cubic or tetragonal) did not influence the electrochemical behavior in this CFO system. Second, regarding crystallite size and wire diameter, CFO wires with larger crystallite sizes exhibit improved cycling stability, while wires possessing smaller diameters exhibiting higher capacities. Finally, the electrochemical behavior is strongly influenced by the electrode architecture, with CFO-CNT binder-free electrodes demonstrating significantly higher capacities and cycling stability compared to conventionally prepared coatings. The mechanism(s) associated with the high capacities under low current density but limited electrochemical reversibility of CFO electrodes under high current density were probed via x-ray absorption spectroscopy (XAS) mapping with sub-micron spatial resolution for the first time. Results suggest that the capacity of the binder-free electrodes under high rate is limited by the irreversible formation of Cu 0, as well as limited reduction of Fe 3+, to Fe 2+ not Fe 0. The results (1) shed fundamental insight into the reversibility of CuFe 2O 4 materials cycled at high current density and (2) demonstrate that a synergistic effort to control both active material morphology and electrode architecture is an effective strategy for optimizing electrochemical behavior.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Lei; Bock, David C.; Li, Jing
Here, a series of one-dimensional CuFe 2O 4 nano/sub-micron wires possessing different diameters, crystal phases, and crystal sizes have been successfully generated using a facile template-assisted co precipitation reaction at room temperature, followed by a short post-annealing process. The diameter and the crystal structure of the resulting CuFe 2O4 (CFO) wires were judiciously tuned by varying the pore size of the template and the post-annealing temperature, respectively. Carbon nanotubes (CNTs) were incorporated to generate CFO-CNT binder-free anodes, and multiple characterization techniques were employed with the goal of delineating the relationships between electrochemical behavior and the properties of both the CFOmore » wires (crystal phase, wire diameter, crystal size) and the electrode architecture (binder-free vs. conventionally prepared approaches). The study reveals several notable findings. First, the crystal phase (cubic or tetragonal) did not influence the electrochemical behavior in this CFO system. Second, regarding crystallite size and wire diameter, CFO wires with larger crystallite sizes exhibit improved cycling stability, while wires possessing smaller diameters exhibiting higher capacities. Finally, the electrochemical behavior is strongly influenced by the electrode architecture, with CFO-CNT binder-free electrodes demonstrating significantly higher capacities and cycling stability compared to conventionally prepared coatings. The mechanism(s) associated with the high capacities under low current density but limited electrochemical reversibility of CFO electrodes under high current density were probed via x-ray absorption spectroscopy (XAS) mapping with sub-micron spatial resolution for the first time. Results suggest that the capacity of the binder-free electrodes under high rate is limited by the irreversible formation of Cu 0, as well as limited reduction of Fe 3+, to Fe 2+ not Fe 0. The results (1) shed fundamental insight into the reversibility of CuFe 2O 4 materials cycled at high current density and (2) demonstrate that a synergistic effort to control both active material morphology and electrode architecture is an effective strategy for optimizing electrochemical behavior.« less
Wired and Wireless Camera Triggering with Arduino
NASA Astrophysics Data System (ADS)
Kauhanen, H.; Rönnholm, P.
2017-10-01
Synchronous triggering is an important task that allows simultaneous data capture from multiple cameras. Accurate synchronization enables 3D measurements of moving objects or from a moving platform. In this paper, we describe one wired and four wireless variations of Arduino-based low-cost remote trigger systems designed to provide a synchronous trigger signal for industrial cameras. Our wireless systems utilize 315 MHz or 434 MHz frequencies with noise filtering capacitors. In order to validate the synchronization accuracy, we developed a prototype of a rotating trigger detection system (named RoTriDeS). This system is suitable to detect the triggering accuracy of global shutter cameras. As a result, the wired system indicated an 8.91 μs mean triggering time difference between two cameras. Corresponding mean values for the four wireless triggering systems varied between 7.92 and 9.42 μs. Presented values include both camera-based and trigger-based desynchronization. Arduino-based triggering systems appeared to be feasible, and they have the potential to be extended to more complicated triggering systems.
Berend, Keith R; Lombardi, Adolph V; Mallory, Thomas H; Chonko, Douglas J; Dodds, Kathleen L; Adams, Joanne B
2004-10-01
Initial stability is critical for fixation and survival of cementless total hip arthroplasty. Occasionally, a split of the calcar occurs intraoperatively. A review of 1,320 primary total hip arthroplasties with 2-year follow-up, performed between August 1985 and February 2001 using the Mallory-Head Porous tapered femoral component, revealed 58 hips in 55 patients with an intraoperative calcar fracture managed with single or multiple cerclage wires or cables and immediate full weight bearing. At 7.5 years average follow-up (range, 2-16 years), there were no revisions of the femoral component, radiographic failures, or patients with severe thigh pain, for a stem survival rate of 100%. Average Harris hip score improvement was 33.8 points. Fracture of the proximal femur occurs in approximately 4% of primary THAs using the Mallory-Head Porous femoral component. When managed intraoperatively with cerclage wire or cable, the mid- to long-term results appear unaffected with 100% femoral component survival at up to 16 years.
NASA Astrophysics Data System (ADS)
Collins, Gilbert; Valenzuela, Julio; Aybar, Nicholas; Conti, Fabio; Beg, Farhat
2017-10-01
We report on the effects wire material on collisionality and radiative cooling on the interactions of counter-streaming plasma jets produced by conical wire arrays on the 200 kA GenASIS driver. In these interactions, mean free path (λmfp) scales with jet velocity (vjet4),atomic mass (A2), and ionization (Z*-4), while cooling scales with atomic mass. By changing the material of the jets one can create slowly cooling, weakly collisional regimes using C, Al, or Cu, or strongly cooled, effectively collisionless plasmas using Mo or W. The former produced smooth shocks soon after the jets collide (near the peak current of 150 ns) that grew in size over time. Interactions of the latter produced multiple structures of a different shape, at a later time ( 300 ns) that dissipated rapidly compared to the lower Z materials. We will report on the scaleability of these different materials to astrophysical phenomena. This work was partially supported by the Department of Energy Grant Number DE-SC0014493.
Anatomy of RISC: how do small RNAs and chaperones activate Argonaute proteins?
Nakanishi, Kotaro
2016-09-01
RNA silencing is a eukaryote-specific phenomenon in which microRNAs and small interfering RNAs degrade messenger RNAs containing a complementary sequence. To this end, these small RNAs need to be loaded onto an Argonaute protein (AGO protein) to form the effector complex referred to as RNA-induced silencing complex (RISC). RISC assembly undergoes multiple and sequential steps with the aid of Hsc70/Hsp90 chaperone machinery. The molecular mechanisms for this assembly process remain unclear, despite their significance for the development of gene silencing techniques and RNA interference-based therapeutics. This review dissects the currently available structures of AGO proteins and proposes models and hypotheses for RISC assembly, covering the conformation of unloaded AGO proteins, the chaperone-assisted duplex loading, and the slicer-dependent and slicer-independent duplex separation. The differences in the properties of RISC between prokaryotes and eukaryotes will also be clarified. WIREs RNA 2016, 7:637-660. doi: 10.1002/wrna.1356 For further resources related to this article, please visit the WIREs website. © 2016 The Authors. WIREs RNA published by Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Matsuda, Y.; Kakutani, K.; Nonomura, T.; Kimbara, J.; Osamura, K.; Kusakar, S.; Toyoda, H.
2015-10-01
An electric field screen can be used to keep mosquitoes out of houses with open windows. In this study, doubly charged dipolar electric field screens (DD-screens) were used to capture mosquitoes entering through a window. The screen had two components: three layers of insulated conductor iron wires (ICWs) in parallel arrays and two electrostatic direct current (DC) voltage generators that supplied negative or positive voltages to the ICWs. Within each layer, the ICWs were parallel at 5-mm intervals, and connected to each other and to a negative or positive voltage generator. The negatively and positively charged ICWs are represented as ICW(-) and ICW(+), respectively. The screen consisted of one ICW(+) layer with an ICW(-) layer on either side. The Asian tiger mosquito (Aedes albopictus) and house mosquito (Culex pipiens) were used as models of vectors carrying viral pathogens. Adult mosquitoes were blown into the space between the ICWs by sending compressed air through the tip of an insect aspirator to determine the voltage range that captured all of the test insects. Wind speed was measured at the surface of the ICW using a sensitive anemometer. The result showed that at ≥ 1.2 kV, the force was strong enough that the ICWs captured all of the mosquitoes, despite a wind speed of 7 m/s. Therefore, the DD-screen could serve as a physical barrier to prevent noxious mosquitoes from entering houses with good air penetration.
NASA Technical Reports Server (NTRS)
Dubin, Matthew B. (Inventor); Larson, Brent D. (Inventor); Kolosowsky, Aleksandra (Inventor)
2006-01-01
A modular and scalable seamless tiled display apparatus includes multiple display devices, a screen, and multiple lens assemblies. Each display device is subdivided into multiple sections, and each section is configured to display a sectional image. One of the lens assemblies is optically coupled to each of the sections of each of the display devices to project the sectional image displayed on that section onto the screen. The multiple lens assemblies are configured to merge the projected sectional images to form a single tiled image. The projected sectional images may be merged on the screen by magnifying and shifting the images in an appropriate manner. The magnification and shifting of these images eliminates any visual effect on the tiled display that may result from dead-band regions defined between each pair of adjacent sections on each display device, and due to gaps between multiple display devices.
Franco, Érika Mendonça Fernandes; Valarelli, Fabrício Pinelli; Fernandes, João Batista; Cançado, Rodrigo Hermont; de Freitas, Karina Maria Salvatore
2015-01-01
Abstract Objective: The aim of this study was to compare torque expression in active and passive self-ligating and conventional brackets. Methods: A total of 300 segments of stainless steel wire 0.019 x 0.025-in and six different brands of brackets (Damon 3MX, Portia, In-Ovation R, Bioquick, Roth SLI and Roth Max) were used. Torque moments were measured at 12°, 24°, 36° and 48°, using a wire torsion device associated with a universal testing machine. The data obtained were compared by analysis of variance followed by Tukey test for multiple comparisons. Regression analysis was performed by the least-squares method to generate the mathematical equation of the optimal curve for each brand of bracket. Results: Statistically significant differences were observed in the expression of torque among all evaluated bracket brands in all evaluated torsions (p < 0.05). It was found that Bioquick presented the lowest torque expression in all tested torsions; in contrast, Damon 3MX bracket presented the highest torque expression up to 36° torsion. Conclusions: The connection system between wire/bracket (active, passive self-ligating or conventional with elastic ligature) seems not to interfere in the final torque expression, the latter being probably dependent on the interaction between the wire and the bracket chosen for orthodontic mechanics. PMID:26691972
Wenstrom, K D; Boots, L R; Cosper, P C
1996-01-01
The goal of this study was to determine if the multiple marker screening test (maternal serum alpha-fetoprotein, unconjugated estriol, human chorionic gonadotrophin, and maternal age) detects fetal Turner syndrome or just cystic hygroma/hydrops. Multiple marker screening tests from 4 groups were compared: 1) Turner syndrome with hydrops/ hygroma group (n = 10) = fetuses with cystic hygroma/hydrops and a 45X karyotype, 2) Turner syndrome without hydrops/hygroma (n = 9) = sonographically unremarkable fetal Turner syndrome or Turner mosaic, 3) hydrops group (n = 8) = all cases of fetal cystic hygroma/hydrops excluding Turner syndrome, 4) sex chromosome aneuploidy group (n = 16) = other sonographically normal fetal sex chromosome aneuploidies. Positive screening tests (Down syndrome risk > or = 1:190 or MSAFP > or = 2.5 MOM) were found in 60% (6/10) of the Turner syndrome with hydrops/hygroma group, but only 11% (1/9) of the Turner syndrome without hydrops/hygroma group (P = .04). The incidence of positive screening tests in the Hydrops group was 75% (6/8), while it was only 12.5% (2/16) in the other sex chromosome aneuploidy group. We conclude that the multiple marker screening test identifies fetuses with cystic hygroma/hydrops, and may do so independently of the etiology of the hydrops.
NASA Astrophysics Data System (ADS)
Alejandro Juárez-Reyes, Salvador; Sosa-Sánchez, Citlalli Teresa; Silva-Ortigoza, Gilberto; de Jesús Cabrera-Rosas, Omar; Espíndola-Ramos, Ernesto; Ortega-Vidals, Paula
2018-03-01
Among the best known non-interferometric optical tests are the wire test, the Foucault test and Ronchi test with a low frequency grating. Since the wire test is the seed to understand the other ones, the aim of the present work is to do a thorough study of this test for a lens with symmetry of revolution and to do this study for any configuration of the object and detection planes where both planes could intersect: two, one or no branches of the caustic region (including the marginal and paraxial foci). To this end, we calculated the vectorial representation for the caustic region, and we found the analytical expression for the pattern; we report that the analytical pattern explicitly depends on the magnitude of a branch of the caustic. With the analytical pattern we computed a set of simulations of a dynamical adaptation of the optical wire test. From those simulations, we have done a thorough analysis of the topological structure of the pattern; so we explain how the multiple image formation process and the image collapse process take place for each configuration, in particular, when both the wire and the detection planes are placed inside the caustic region, which has not been studied before. For the first time, we remark that not only the intersections of the object and detection planes with the caustic are important in the change of pattern topology; but also the projection of the intersection between the caustic and the object plane mapped onto the detection plane; and the virtual projection of the intersection between the caustic and the detection plane mapped onto the object plane. We present that for the new configurations of the optical system, the wire image is curves of the Tschirnhausen’s cubic, the piriform and the deformed eight-curve types.
An, Byeong Wan; Kim, Kukjoo; Lee, Heejoo; Kim, So-Yun; Shim, Yulhui; Lee, Dae-Young; Song, Jun Yeob; Park, Jang-Ung
2015-08-05
Electrohydrodynamic-inkjet-printed high-resolution complex 3D structures with multiple functional inks are demonstrated. Printed 3D structures can have a variety of fine patterns, such as vertical or helix-shaped pillars and straight or rounded walls, with high aspect ratios (greater than ≈50) and narrow diameters (≈0.7 μm). Furthermore, the formation of freestanding, bridge-like Ag wire structures on plastic substrates suggests substantial potentials as high-precision, flexible 3D interconnects. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Gamo, H.; Majumdar, A. K.
1978-01-01
Consideration is given to an atmospheric turbulence chamber designed for optical wave propagation experiments. The chamber consists of ten small electric heater/blowers with an aluminum foil screen and three screens of 2-mm aluminum wire meshes. Calculations are made of the temperature structure constant squared on the basis of temperature structure function measurements derived from a differential microthermocouple system. Values are presented for the refractive-index structure constant squared. The average wind velocity and temperature are found to be, respectively, 0.41 m/sec and 53 C. The inner and outer scales of turbulence are 5.0 mm and 6.5 cm. It is shown that the measured temperature structure function and the power spectrum of temperature fluctuations satisfy, respectively, the 2/3 and -5/3 power similarity laws in the inertial subrange. Possible chamber improvements are discussed.
ERIC Educational Resources Information Center
Gamble-Risley, Michelle
2006-01-01
In the past, projection systems were large, heavy, and unwieldy and cost $3,000 to $5,000. Setup was fraught with the challenges of multiple wires plugged into the backs of desktop computers, often causing confusion about what went where. Systems were sometimes so difficult to set up that teachers had to spend pre-class time putting them together.…
Pierce, J.D.
1994-08-16
A container for hazardous materials capable of protecting the enclosed materials from high speed impact is disclosed. Energy absorption is provided by a multiplicity of crushable layers of either wire mesh or perforated metal sheets which thin and flow together under impact loading. Layers of a higher tensile strength material are interspersed within the crushable layers to confine them and increase performance. 1 fig.
A cross docking pipeline for improving pose prediction and virtual screening performance
NASA Astrophysics Data System (ADS)
Kumar, Ashutosh; Zhang, Kam Y. J.
2018-01-01
Pose prediction and virtual screening performance of a molecular docking method depend on the choice of protein structures used for docking. Multiple structures for a target protein are often used to take into account the receptor flexibility and problems associated with a single receptor structure. However, the use of multiple receptor structures is computationally expensive when docking a large library of small molecules. Here, we propose a new cross-docking pipeline suitable to dock a large library of molecules while taking advantage of multiple target protein structures. Our method involves the selection of a suitable receptor for each ligand in a screening library utilizing ligand 3D shape similarity with crystallographic ligands. We have prospectively evaluated our method in D3R Grand Challenge 2 and demonstrated that our cross-docking pipeline can achieve similar or better performance than using either single or multiple-receptor structures. Moreover, our method displayed not only decent pose prediction performance but also better virtual screening performance over several other methods.
Measurements of matric and water potentials in unsaturated tuff at Yucca Mountain, Nevada
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thamir, F.; McBride, C.M.
1985-12-31
Two types of instruments were installed in a borehole in order to monitor matric and water potentials of various hydrogeologic units consisting of tuff. The borehole was drilled as part of a study to provide information to the US Department of Energy for their use in evaluating Yucca Mountain, Nevada, for a repository for high-level radioactive waste. Heat-dissipation probes were used to monitor matric potentials and thermocouple psychrometers were used to monitor water potentials. Two major concerns regarding the use of these instruments in deep boreholes are: (1) the effect of length of the lead wires, and (2) the inabilitymore » to recalibrate the instruments after installation. The length of the lead wire contributes to the source resistance and lead capacitance, which affects the signal settling time. Both instruments tested proved to be insensitive to lead-wire length, except when connected to smaller input-impedance data loggers. Thermocouple wires were more sensitive than heat-dissipation probe wires because of their greater resistance and quality of voltmeters used. Two thermocouple psychrometers were installed at every instrument station for backup and verification of data, because the instruments could not be recalibrated in situ. Multiple scanning rather than single-point scanning of the evaporation curve of a thermocouple psychrometer could give more reliable data, especially in differentiating between very wet and very dry environments. An isolated power supply needs to be used for each heat dissipation probe rather than a single power supply for a group of probes to avoid losing data from all probes when one probe malfunctions. This type of system is particularly desirable if the site is unattended by an operator for as long as a month. 20 refs., 13 figs., 2 tabs.« less
Bonner, Oliver; Beardsall, Kathryn; Crilly, Nathan; Lasenby, Joan
2017-02-01
The neonatal intensive care unit (NICU) can be one of the most stressful hospital environments. Alongside providing intensive clinical care, it is important that parents have the opportunity for regular physical contact with their babies because the neonatal period is critical for parent-child bonding. At present, monitoring technology in the NICU requires multiple wired sensors to track each baby's vital signs. This study describes the experiences that parents and nurses have with the current monitoring methods, and reports on their responses to the concept of a wireless monitoring system. Semistructured interviews were conducted with six parents, each of whom had babies on the unit, and seven nurses who cared for those babies. The interviews initially focused on the participants' experiences of the current wired system and then on their responses to the concept of a wireless system. The transcripts were analysed using a general inductive approach to identify relevant themes. Participants reported on physical and psychological barriers to parental care, the ways in which the current system obstructed the efficient delivery of clinical care and the perceived benefits and risks of a wireless system. The parents and nurses identified that the wires impeded baby-parent bonding; physically and psychologically. While a wireless system was viewed as potentially enabling greater interaction, staff and parents highlighted potential concerns, including the size, weight and battery life of any new device. The many wires required to safely monitor babies within the NICU creates a negative environment for parents at a critical developmental period, in terms of physical and psychological interactions. Nurses also experience challenges with the existing system, which could negatively impact the clinical care delivery. Developing a wireless system could overcome these barriers, but there remain challenges in designing a device suitable for this unique environment.
Gupt, Parikshit; Nagpal, Archana; Samra, Rupandeep Kaur; Verma, Ramit; Kaur, Jasjeet; Abrol, Surbhi
2017-01-01
The purpose of the study was to evaluate the fracture strength of provisional fixed partial dentures made of autopolymerizing polymethylmethacrylate (PMMA) resin using different types of reinforcement materials to determine the best among them. Fifty samples were made (10 samples for each group) with autopolymerizing PMMA resin using reinforcement materials (stainless steel wire: looped and unlooped and glass fiber: loose and unidirectional) as 3-unit posterior bridge. The test specimens were divided into five groups depending on the reinforcing material as Group I, II, III, IV, and V; Group I: PMMA unreinforced (control group), Group II: PMMA reinforced with stainless steel wire (straight ends), Group III: PMMA reinforced with stainless steel wire (looped ends), Group IV: PMMA reinforced with unidirectional glass fibers, and Group V: PMMA reinforced with randomly distributed glass fibers. Universal testing machine was used to evaluate and compare the fracture strength of samples. Comparison of mean ultimate force and ultimate stress was done employing one-way analysis of variance and Tukey's post hoc tests. The highest and lowest mean ultimate force and mean ultimate stress were of Group IV and I, respectively. Tukey's post hoc honestly significant difference multiple comparison for mean ultimate force and stress shows the increase in strength to be statistically significant ( P < 0.05) except for the samples reinforced with randomly distributed glass fibers ( P > 0.05). Unidirectional glass fibers showed the maximum strength, which was comparable to mean values of both stainless steel wire groups. Low cost and easy technique of using stainless steel wire make it the material of choice over the unidirectional glass fiber for reinforcement in nonesthetic areas where high strength is required.
The Need for Screening, Assessment, and Treatment for Cognitive Dysfunction in Multiple Sclerosis
Benedict, Ralph H.B.; Gromisch, Elizabeth S.; DeLuca, John
2012-01-01
Cognitive dysfunction is observed in about half of people with multiple sclerosis (MS), and MS health-care professionals face the challenge of screening, assessing, and treating patients for cognitive problems. Considering the inconsistent or limited empirical evidence to assist in this task, a multidisciplinary consensus conference of MS experts, sponsored by the Consortium of Multiple Sclerosis Centers (CMSC), was held on September 24, 2010, to address these issues. Key articles from the literature on these topics were distributed prior to the meeting, and CMSC member professionals were surveyed on clinical practices related to screening, assessment, and treatment for cognitive problems. The purpose of the meeting was threefold: 1) to achieve a multidisciplinary perspective on practices for screening, monitoring, evaluating, and treating MS patients for cognitive problems; 2) to propose consensus candidate measures for screening and/or monitoring for cognitive problems in MS that neurologists or nurses might administer on a regular basis; and 3) to propose consensus treatment approaches from a multidisciplinary perspective. This article summarizes the conclusions of the conference participants and provides preliminary suggestions for screening and brief assessment. PMID:24453735
NASA Technical Reports Server (NTRS)
Freeman, J. W.; Hervey, D.; Glaser, P.
1980-01-01
A preliminary study of the feasibility and cost of an offshore rectenna to serve the upper metropolitan east coast was performed. A candidate site at which to build a 5 GW rectenna was selected on the basis of proximity to load centers, avoidance of shipping lanes, sea floor terrain, and relocated conditions. Several types of support structures were selected for study based initially on the reference system rectenna concept of a wire mesh ground screen and dipoles each with its own rectifier and filter circuits. Possible secondary uses of an offshore rectenna were examined and are evaluated.
A Reactive-Heat-Pipe for Combined Heat Generation and Transport
1977-12-01
The Lennard - Jones potential parameters a and F-1 can be found in Ar Ar Table 2.3 of Reference [26]. They are a Ar =3.542 A ~Ar -=93.3 K The above...Specific Heat Ratio Wire Spacing of Screen S Volume Fraction of Solid Phase in Wick or Lennard Jones Force Constant e’ Wick Void Fraction 1Viscusity p...Density a Surface Tension G Condensation Coefficient c e Evaporation Coefficient*e U Lennard - Jones Force Constant Subscripts A Position A in Figure 13 Ar
ONRASIA Scientific Information Bulletin, Volume 18 Number 1, January - March 1993,
1993-03-01
synthesized with half- mirrors to achieve this 3-D ers hope to be able to reflect time relationships in realization. This permits a 3-D visualization...field because the wires that stretch in all directions will of vision, so a mirror is placed in front of the become tangled. operator’s face at an...angle of 450 and the computer screen is prtjccted there. Thus the mirror hides the c. Joy Stick hands from view. "If we can recreate the trial-and-error
High-Tc thermal bridges for space-borne cryogenic infrared detectors
NASA Technical Reports Server (NTRS)
Wise, S. A.; Buckley, J. D.; Nolt, I.; Hooker, M. W.; Haertling, G. H.; Selim, R.; Caton, R.; Buoncristiani, A. M.
1993-01-01
The potential for using high-temperature superconductive elements, screen-printed onto ceramic substrates, as thermal bridges to replace the currently employed manganin wires is studied at NASA-LaRC. Substrate selection is considered to be the most critical parameter in device production. Due to the glass-like thermal behavior of yttria-stabilized-zirconia (YSZ) and fused silica substrates, these materials are found to reduce the heat load significantly. The estimated thermal savings for superconductive leads printed onto YSZ or fused silica substrates range from 6 to 14 percent.
Colorectal cancer screening: The role of the noninvasive options.
Dickerson, Lisa; Varcak, Susan Combs
2016-09-01
Recommended screening options for colorectal cancer are divided into noninvasive stool-based options, and invasive procedure-based options. Because multiple screening strategies are effective, efforts to reduce deaths from colorectal cancer should focus on maximizing the number of patients who are screened. This article reviews noninvasive stool-based screening options.
Steeves, Jeremy A; Thompson, Dixie L; Bassett, David R; Fitzhugh, Eugene C; Raynor, Hollie A
2012-01-01
Previous research suggests that reducing sedentary screen behaviors may be a strategy for preventing and treating obesity in children. This systematic review describes strategies used in interventions designed to either solely target sedentary screen behaviors or multiple health behaviors, including sedentary screen behaviors. Eighteen studies were included in this paper; eight targeting sedentary screen behaviors only, and ten targeting multiple health behaviors. All studies used behavior modification strategies for reducing sedentary screen behaviors in children (aged 1-12 years). Nine studies only used behavior modification strategies, and nine studies supplemented behavior modification strategies with an electronic device to enhance sedentary screen behaviors reductions. Many interventions (50%) significantly reduced sedentary screen behaviors; however the magnitude of the significant reductions varied greatly (-0.44 to -3.1 h/day) and may have been influenced by the primary focus of the intervention, number of behavior modification strategies used, and other tools used to limit sedentary screen behaviors.
Practical applications of current loop signal conditioning
NASA Astrophysics Data System (ADS)
Anderson, Karl F.
1994-10-01
This paper describes a variety of practical application circuits based on the current loop signal conditioning paradigm. Equations defining the circuit response are also provided. The constant current loop is a fundamental signal conditioning circuit concept that can be implemented in a variety of configurations for resistance-based transducers, such as strain gages and resistance temperature devices. The circuit features signal conditioning outputs which are unaffected by extremely large variations in lead wire resistance, direct current frequency response, and inherent linearity with respect to resistance change. Sensitivity of this circuit is double that of a Wheatstone bridge circuit. Electrical output is zero for resistance change equals zero. The same excitation and output sense wires can serve multiple transducers. More application arrangements are possible with constant current loop signal conditioning than with the Wheatstone bridge.
Two-dimensional fringe probing of transient liquid temperatures in a mini space.
Xue, Zhenlan; Qiu, Huihe
2011-05-01
A 2D fringe probing transient temperature measurement technique based on photothermal deflection theory was developed. It utilizes material's refractive index dependence on temperature gradient to obtain temperature information from laser deflection. Instead of single beam, this method applies multiple laser beams to obtain 2D temperature information. The laser fringe was generated with a Mach-Zehnder interferometer. A transient heating experiment was conducted using an electric wire to demonstrate this technique. Temperature field around a heating wire and variation with time was obtained utilizing the scattering fringe patterns. This technique provides non-invasive 2D temperature measurements with spatial and temporal resolutions of 3.5 μm and 4 ms, respectively. It is possible to achieve temporal resolution to 500 μs utilizing the existing high speed camera.
Current loop signal conditioning: Practical applications
NASA Technical Reports Server (NTRS)
Anderson, Karl F.
1995-01-01
This paper describes a variety of practical application circuits based on the current loop signal conditioning paradigm. Equations defining the circuit response are also provided. The constant current loop is a fundamental signal conditioning circuit concept that can be implemented in a variety of configurations for resistance-based transducers, such as strain gages and resistance temperature detectors. The circuit features signal conditioning outputs which are unaffected by extremely large variations in lead wire resistance, direct current frequency response, and inherent linearity with respect to resistance change. Sensitivity of this circuit is double that of a Wheatstone bridge circuit. Electrical output is zero for resistance change equals zero. The same excitation and output sense wires can serve multiple transducers. More application arrangements are possible with constant current loop signal conditioning than with the Wheatstone bridge.
Micropillar arrays as a high-throughput screening platform for therapeutics in multiple sclerosis.
Mei, Feng; Fancy, Stephen P J; Shen, Yun-An A; Niu, Jianqin; Zhao, Chao; Presley, Bryan; Miao, Edna; Lee, Seonok; Mayoral, Sonia R; Redmond, Stephanie A; Etxeberria, Ainhoa; Xiao, Lan; Franklin, Robin J M; Green, Ari; Hauser, Stephen L; Chan, Jonah R
2014-08-01
Functional screening for compounds that promote remyelination represents a major hurdle in the development of rational therapeutics for multiple sclerosis. Screening for remyelination is problematic, as myelination requires the presence of axons. Standard methods do not resolve cell-autonomous effects and are not suited for high-throughput formats. Here we describe a binary indicant for myelination using micropillar arrays (BIMA). Engineered with conical dimensions, micropillars permit resolution of the extent and length of membrane wrapping from a single two-dimensional image. Confocal imaging acquired from the base to the tip of the pillars allows for detection of concentric wrapping observed as 'rings' of myelin. The platform is formatted in 96-well plates, amenable to semiautomated random acquisition and automated detection and quantification. Upon screening 1,000 bioactive molecules, we identified a cluster of antimuscarinic compounds that enhance oligodendrocyte differentiation and remyelination. Our findings demonstrate a new high-throughput screening platform for potential regenerative therapeutics in multiple sclerosis.
Immobilized OBOC combinatorial bead array to facilitate multiplicative screening.
Xiao, Wenwu; Bononi, Fernanda C; Townsend, Jared; Li, Yuanpei; Liu, Ruiwu; Lam, Kit S
2013-07-01
One-bead-one-compound (OBOC) combinatorial library screening has been broadly utilized for the last two decades to identify small molecules, peptides or peptidomimetics targeting variable screening probes such as cell surface receptors, bacteria, protein kinases, phosphatases, proteases etc. In previous screening methods, library beads were suspended in solution and screened against one single probe. Only the positive beads were tracked and isolated for additional screens and finally selected for chemical decoding. During this process, the remaining negative beads were not tracked and discarded. Here we report a novel bead immobilization method such that a bead library array can be conveniently prepared and screened in its entirety, sequentially many times with a series of distinct probes. This method not only allows us to increase the screening efficiency but also permits us to determine the binding profile of each and every library bead against a large number of target receptors. As proof of concept, we serially screened a random OBOC disulfide containing cyclic heptapeptide library with three water soluble dyes as model probes: malachite green, bromocresol purple and indigo carmine. This multiplicative screening approach resulted in a rapid determination of the binding profile of each and every bead respective to each of the three dyes. Beads that interacted with malachite green only, bromocresol purple only, or both indigo carmine and bromocresol purple were isolated, and their peptide sequences were determined with microsequencer. Ultimately, the novel OBOC multiplicative screening approach could play a key role in the enhancement of existing on-bead assays such as whole cell binding, bacteria binding, protein binding, posttranslational modifications etc. with increased efficiency, capacity, and specificity.
Behavioral phenotyping of mice in pharmacological and toxicological research.
Karl, Tim; Pabst, Reinhard; von Hörsten, Stephan
2003-07-01
The evaluation of behavioral effects is an important component for the in vivo screening of drugs or potentially toxic compounds in mice. Ideally, such screening should be composed of monitoring general health, sensory functions, and motor abilities, right before specific behavioral domains are tested. A rational strategy in the design and procedure of testing as well as an effective composition of different well-established and reproducible behavioral tests can minimize the risk of false positive and false negative results in drug screening. In the present review we describe such basic considerations in planning experiments, selecting strains of mice, and propose groups of behavioral tasks suitable for a reliable detection of differences in specific behavioral domains in mice. Screening of general health and neurophysiologic functions (reflexes, sensory abilities) and motor function (pole test, wire hang test, beam walking, rotarod, accelerod, and footprint) as well as specific hypothesis-guided testing in the behavioral domains of learning and memory (water maze, radial maze, conditioned fear, and avoidance tasks), emotionality (open field, hole board, elevated plus maze, and object exploration), nociception (tail flick, hot plate), psychiatric-like conditions (porsolt swim test, acoustic startle response, and prepulse inhibition), and aggression (isolation-induced aggression, spontaneous aggression, and territorial aggression) are described in further detail. This review is designed to describe a general approach, which increases reliability of behavioral screening. Furthermore, it provides an overview on a selection of specific procedures suitable for but not limited to behavioral screening in pharmacology and toxicology.
The BetaCage, an ultra-sensitive screener for surface contamination
NASA Astrophysics Data System (ADS)
Bunker, R.; Ahmed, Z.; Bowles, M. A.; Golwala, S. R.; Grant, D. R.; Kos, M.; Nelson, R. H.; Schnee, R. W.; Rider, A.; Wang, B.; Zahn, A.
2013-08-01
Material screening for identifying low-energy electron emitters and alpha-decaying isotopes is now a prerequisite for rare-event searches (e.g., dark-matter direct detection and neutrinoless double-beta decay) for which surface radiocon-tamination has become an increasingly important background. The BetaCage, a gaseous neon time-projection chamber, is a proposed ultra-sensitive (and nondestructive) screener for alpha-and beta-emitting surface contaminants to which existing screening facilities are insufficiently sensitive. Sensitivity goals are 0.1 betas keV-1 m-2 day-1 and 0.1 alphas m-2 day-1, with the former limited by Compton scattering of photons in the screening samples and (thanks to tracking) the latter expected to be signal-limited; radioassays and simulations indicate backgrounds from detector materials and radon daughters should be subdominant. We report on details of the background simulations and detector design that provide the discrimination, shielding, and radiopurity necessary to reach our sensitivity goals for a chamber with a 95 × 95 cm2 sample area positioned below a 40 cm drift region and monitored by crisscrossed anode and cathode planes consisting of 151 wires each.
NASA Astrophysics Data System (ADS)
Safir, Abdelilah; Mudd, David; Yazdanpanah, Mehdi; Dobrokhotov, Vladimir; Sumanasekera, Gamini; Cohn, Robert
2008-03-01
In this work, we report a recent experimental study of high emission current densities exceeding 10mA/cm^2 and breakdown electric field lower than 5Volts/μm from novel cold cathodes such as conical shaped carbon nanopipettes (CNP). CNP were grown by CVD on Pt wire and have apex as sharp as 10nm with length between 3-6μm. The emission experiments were conducted under vacuum in a scanning electron microscope for individual CNP and in a dedicated chamber for bulk samples. CNP's conical bases and low density contribute significantly to the reduction of the screening effect and to the field emission enhancement. The experimental value for the field enhancement factor, γ, was about 867. Comparing emission results taken from CNP and aligned multiwall carbon nanotubes (MWNT) show that the ratio between γCNP and γMWNT is ˜1.6 which contributes to the reduction of screening effect. The emission from multilayers of graphene was also studied. High emission current (20μA) demonstrates promising emission properties of graphene.
Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D
2014-03-01
Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.
Flat Plate Boundary Layer Stimulation Using Trip Wires and Hama Strips
NASA Astrophysics Data System (ADS)
Peguero, Charles; Henoch, Charles; Hrubes, James; Fredette, Albert; Roberts, Raymond; Huyer, Stephen
2017-11-01
Water tunnel experiments on a flat plate at zero angle of attack were performed to investigate the effect of single roughness elements, i.e., trip wires and Hama strips, on the transition to turbulence. Boundary layer trips are traditionally used in scale model testing to force a boundary layer to transition from laminar to turbulent flow at a single location to aid in scaling of flow characteristics. Several investigations of trip wire effects exist in the literature, but there is a dearth of information regarding the influence of Hama strips on the flat plate boundary layer. The intent of this investigation is to better understand the effects of boundary layer trips, particularly Hama strips, and to investigate the pressure-induced drag of both styles of boundary layer trips. Untripped and tripped boundary layers along a flat plate at a range of flow speeds were characterized with multiple diagnostic measurements in the NUWC/Newport 12-inch water tunnel. A wide range of Hama strip and wire trip thicknesses were used. Measurements included dye flow visualization, direct skin friction and parasitic drag force, boundary layer profiles using LDV, wall shear stress fluctuations using hot film anemometry, and streamwise pressure gradients. Test results will be compared to the CFD and boundary layer model results as well as the existing body of work. Conclusions, resulting in guidance for application of Hama strips in model scale experiments and non-dimensional predictions of pressure drag will be presented.
Preliminary Experience with use of Qureshi-5 Catheters for Diagnostic Cerebral Angiography.
Qureshi, Adnan I; Yan, Xiao; Liu, HongLiang
2015-05-01
A catheter technique was developed to overcome current challenges in the stabilization and manipulation of catheter in tortuous arteries such as right subclavian artery and left common carotid artery. The new catheter has the following two lumens: first lumen can accommodate a 0.035-inch guide wire (lumen A) and a curved shape at the distal end; the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen (lumen B). The catheter is withdrawn or advanced over the 0.018-inch guide wire and the curved free end of catheter manipulated until the end engages the origin of the target artery. Subsequently, either contrast can be injected or a 0.035-inch guide wire advanced into the target artery. The catheters were used in two patients to perform diagnostic cerebral angiography through a 6F introducer sheath placed in the right common femoral artery. The left and right common carotid arteries and left and right vertebral arteries were catheterized in first patient (contrast used 50 ml; fluoroscopy time 20:09 min). The left and right internal carotid arteries, left and right subclavian arteries, and left external carotid artery were catheterized in second patient (contrast used 40 ml; fluoroscopy time 13:56 min). No complications were observed in either of the two patients. The performance of the new catheter for catheterization of multiple arteries in two patients was considered adequate with high-quality angiographic image acquisitions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Naderi, G., E-mail: gnaderi@ncsu.edu; Schwartz, J.
2014-04-14
Despite progress in the performance of Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub x} (Bi2212)/Ag multifilamentary round wires, understanding the impact of microstructural defects on multiple length scales on electrical transport remains a significant challenge. Many recent studies have focused on porosity, but porosity is not the only factor in determining J{sub c}. The primary impurity in partial-melt processed multifilamentary Bi2212 wires is Bi{sub 2}Sr{sub 2}CuO{sub x} (Bi2201), which forms as mesoscopic grains and nanoscopic intergrowths. Previously, we showed the destructive effect of Bi2201 grains on transport. Here, we relate scanning transmission electron microscopy results to the Bi2212 coherence length, anisotropic magnetization behavior,more » and magnetic-field dependent transport to study c-axis transport and the effects of Bi2201 intergrowths on magnetic flux pinning. We show that wide Bi2201 intergrowths are barrier to c-axis transport within Bi2212 grains, whereas narrow (half- and full-cell) Bi2201 intergrowths are not detrimental to c-axis transport and are likely magnetic flux pinning centers. These results have significant impact on the understanding of Bi2212/Bi2201 systems and provide important physical insight towards future improvements in devices based upon wires, film, and junctions.« less
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 77.1802 Section 77.1802... Wires and Trolley Feeder Wires § 77.1802 Insulation of trolley wires, trolley feeder wires and bare...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 77.1802 Section 77.1802... Wires and Trolley Feeder Wires § 77.1802 Insulation of trolley wires, trolley feeder wires and bare...
Multiscale modeling methods in biomechanics.
Bhattacharya, Pinaki; Viceconti, Marco
2017-05-01
More and more frequently, computational biomechanics deals with problems where the portion of physical reality to be modeled spans over such a large range of spatial and temporal dimensions, that it is impossible to represent it as a single space-time continuum. We are forced to consider multiple space-time continua, each representing the phenomenon of interest at a characteristic space-time scale. Multiscale models describe a complex process across multiple scales, and account for how quantities transform as we move from one scale to another. This review offers a set of definitions for this emerging field, and provides a brief summary of the most recent developments on multiscale modeling in biomechanics. Of all possible perspectives, we chose that of the modeling intent, which vastly affect the nature and the structure of each research activity. To the purpose we organized all papers reviewed in three categories: 'causal confirmation,' where multiscale models are used as materializations of the causation theories; 'predictive accuracy,' where multiscale modeling is aimed to improve the predictive accuracy; and 'determination of effect,' where multiscale modeling is used to model how a change at one scale manifests in an effect at another radically different space-time scale. Consistent with how the volume of computational biomechanics research is distributed across application targets, we extensively reviewed papers targeting the musculoskeletal and the cardiovascular systems, and covered only a few exemplary papers targeting other organ systems. The review shows a research subdomain still in its infancy, where causal confirmation papers remain the most common. WIREs Syst Biol Med 2017, 9:e1375. doi: 10.1002/wsbm.1375 For further resources related to this article, please visit the WIREs website. © 2017 The Authors. WIREs Systems Biology and Medicine published by Wiley Periodicals, Inc.
A hydroponic method for plant growth in microgravity
NASA Technical Reports Server (NTRS)
Wright, B. D.
1985-01-01
A hydroponic apparatus under development for long-term microgravity plant growth is described. The capillary effect root environment system (CERES) is designed to keep separate the nutrient and air flows, although both must be simultaneously available to the roots. Water at a pressure slightly under air pressure is allowed to seep into a plastic depression covered by a plastic screen and a porous membrane. A root in the air on the membrane outer surface draws the moisture through it. The laboratory model has a wire-based 1.241 mm mesh polyethylene screen and a filter membrane with 0.45 micron pores, small enough to prohibit root hair penetration. The design eliminates the need to seal-off the plant environment. Problems still needing attention include scaling up of the CERES size, controlling biofouling of the membrane, and extending the applications to plants without fibrous root systems.
Interactive display of molecular models using a microcomputer system
NASA Technical Reports Server (NTRS)
Egan, J. T.; Macelroy, R. D.
1980-01-01
A simple, microcomputer-based, interactive graphics display system has been developed for the presentation of perspective views of wire frame molecular models. The display system is based on a TERAK 8510a graphics computer system with a display unit consisting of microprocessor, television display and keyboard subsystems. The operating system includes a screen editor, file manager, PASCAL and BASIC compilers and command options for linking and executing programs. The graphics program, written in USCD PASCAL, involves the centering of the coordinate system, the transformation of centered model coordinates into homogeneous coordinates, the construction of a viewing transformation matrix to operate on the coordinates, clipping invisible points, perspective transformation and scaling to screen coordinates; commands available include ZOOM, ROTATE, RESET, and CHANGEVIEW. Data file structure was chosen to minimize the amount of disk storage space. Despite the inherent slowness of the system, its low cost and flexibility suggests general applicability.
NASA Technical Reports Server (NTRS)
Tanzer, H. J.
1982-01-01
The feasibility of fabricating and processing liquid metal heat pipes in a low mass honeycomb sandwich panel configuration for application on the NASA Langley airframe-integrated Scramjet engine was investigated. A variety of honeycomb panel facesheet and core-ribbon wick concepts was evaluated within constraints dictated by existing manufacturing technology and equipment. The chosen design consists of an all-stainless steel structure, sintered screen facesheets, and two types of core-ribbon; a diffusion bonded wire mesh and a foil-screen composite. Cleaning, fluid charging, processing, and process port sealing techniques were established. The liquid metals potassium, sodium and cesium were used as working fluids. Eleven honeycomb panels 15.24 cm X 15.24 cm X 2.94 cm were delivered to NASA Langley for extensive performance testing and evaluation; nine panels were processed as heat pipes, and two panels were left unprocessed.
NASA Astrophysics Data System (ADS)
Santos, José; Janeiro, Fernando M.; Ramos, Pedro M.
2015-10-01
This paper presents an embedded liquid viscosity measurement system based on a vibrating wire sensor. Although multiple viscometers based on different working principles are commercially available, there is still a market demand for a dedicated measurement system capable of performing accurate, fast measurements and requiring little or no operator training for simple systems and solution monitoring. The developed embedded system is based on a vibrating wire sensor that works by measuring the impedance response of the sensor, which depends on the viscosity and density of the liquid in which the sensor is immersed. The core of the embedded system is a digital signal processor (DSP) which controls the waveform generation and acquisitions for the measurement of the impedance frequency response. The DSP also processes the acquired waveforms and estimates the liquid viscosity. The user can interact with the measurement system through a keypad and an LCD or through a computer with a USB connection for data logging and processing. The presented system is tested on a set of viscosity standards and the estimated values are compared with the standard manufacturer specified viscosity values. A stability study of the measurement system is also performed.
NASA Technical Reports Server (NTRS)
Noebe, Ronald; Draper, Susan; Gaydosh, Darrell; Garga, Anita; Lerch, Brad; Penney, Nicholas; Begelow, Glen; Padula, Santo, II; Brown, Jeff
2006-01-01
TiNiPt shape memory alloys are particularly promising for use as solid state actuators in environments up to 300 C, due to a reasonable balance of properties, including acceptable work output. However, one of the challenges to commercializing a viable high-temperature shape memory alloy (HTSMA) is to establish the appropriate primary and secondary processing techniques for fabrication of the material in a required product form such as rod and wire. Consequently, a Ti(50.5)Ni(29.5)Pt20 alloy was processed using several techniques including single-pass high-temperature extrusion, multiple-pass high-temperature extrusion, and cold drawing to produce bar stock, thin rod, and fine wire, respectively. The effects of heat treatment on the hardness, grain size, room temperature tensile properties, and transformation temperatures of hot- and cold-worked material were examined. Basic tensile properties as a function of temperature and the strain-temperature response of the alloy under constant load, for the determination of work output, were also investigated for various forms of the Ti(50.5)Ni(29.5)Pt20 alloy, including fine wire.
A method for building low loss multi-layer wiring for superconducting microwave devices
NASA Astrophysics Data System (ADS)
Dunsworth, A.; Barends, R.; Chen, Yu; Chen, Zijun; Chiaro, B.; Fowler, A.; Foxen, B.; Jeffrey, E.; Kelly, J.; Klimov, P. V.; Lucero, E.; Mutus, J. Y.; Neeley, M.; Neill, C.; Quintana, C.; Roushan, P.; Sank, D.; Vainsencher, A.; Wenner, J.; White, T. C.; Neven, H.; Martinis, John M.; Megrant, A.
2018-02-01
Complex integrated circuits require multiple wiring layers. In complementary metal-oxide-semiconductor processing, these layers are robustly separated by amorphous dielectrics. These dielectrics would dominate energy loss in superconducting integrated circuits. Here, we describe a procedure that capitalizes on the structural benefits of inter-layer dielectrics during fabrication and mitigates the added loss. We use a deposited inter-layer dielectric throughout fabrication and then etch it away post-fabrication. This technique is compatible with foundry level processing and can be generalized to make many different forms of low-loss wiring. We use this technique to create freestanding aluminum vacuum gap crossovers (airbridges). We characterize the added capacitive loss of these airbridges by connecting ground planes over microwave frequency λ/4 coplanar waveguide resonators and measuring resonator loss. We measure a low power resonator loss of ˜3.9 × 10-8 per bridge, which is 100 times lower than that of dielectric supported bridges. We further characterize these airbridges as crossovers, control line jumpers, and as part of a coupling network in gmon and fluxmon qubits. We measure qubit characteristic lifetimes (T1s) in excess of 30 μs in gmon devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shafer, D.; Gurovich, V. Tz.; Gleizer, S.
The results of experiments with underwater electrical explosion of modified conical arrays of copper and aluminum wires are presented. A pulsed generator producing a 550 kA-amplitude current with a 400 ns rise time was used in the explosion of the arrays. The array explosion generates water flows converging at the axis of the cone. This flow generates a fast-moving water jet with a velocity exceeding 1.8 × 10{sup 5 }cm/s, which was observed being ejected from the surface of the water covering the array. The positions of the water jet were measured by multiple-exposure fast framing imaging. In experiments, the apex angle of the array,more » the thickness of the water layer above the arrays, or the material of the wires was altered, which changed the resulting velocities and shapes of the emitted jets. A model that considers the converging stationary flow of a slightly compressible fluid is suggested. The velocities and shapes of the jets obtained by this model agree well with the experimentally measured jet velocities.« less
Multiple-Stage Screening of Youth Depression in Schools
ERIC Educational Resources Information Center
Morey, Melissa E.; Arora, Prerna; Stark, Kevin D.
2015-01-01
Schools present a unique environment in which to conduct universal screenings for youth depression. The present study examines the efficiency of a multiple-stage assessment procedure assessing youth depression in the schools by calculating hit rates and establishing diagnostic accuracy for the measures used. Girls (N = 3318) aged 8 to 13,…
Experimenter's Laboratory for Visualized Interactive Science
NASA Technical Reports Server (NTRS)
Hansen, Elaine R.; Rodier, Daniel R.; Klemp, Marjorie K.
1994-01-01
ELVIS (Experimenter's Laboratory for Visualized Interactive Science) is an interactive visualization environment that enables scientists, students, and educators to visualize and analyze large, complex, and diverse sets of scientific data. It accomplishes this by presenting the data sets as 2-D, 3-D, color, stereo, and graphic images with movable and multiple light sources combined with displays of solid-surface, contours, wire-frame, and transparency. By simultaneously rendering diverse data sets acquired from multiple sources, formats, and resolutions and by interacting with the data through an intuitive, direct-manipulation interface, ELVIS provides an interactive and responsive environment for exploratory data analysis.
Microscreen radiation shield for thermoelectric generator
Hunt, Thomas K.; Novak, Robert F.; McBride, James R.
1990-01-01
The present invention provides a microscreen radiation shield which reduces radiative heat losses in thermoelectric generators such as sodium heat engines without reducing the efficiency of operation of such devices. The radiation shield is adapted to be interposed between a reaction zone and a means for condensing an alkali metal vapor in a thermoelectric generator for converting heat energy directly to electrical energy. The radiation shield acts to reflect infrared radiation emanating from the reaction zone back toward the reaction zone while permitting the passage of the alkali metal vapor to the condensing means. The radiation shield includes a woven wire mesh screen or a metal foil having a plurality of orifices formed therein. The orifices in the foil and the spacing between the wires in the mesh is such that radiant heat is reflected back toward the reaction zone in the interior of the generator, while the much smaller diameter alkali metal atoms such as sodium pass directly through the orifices or along the metal surfaces of the shield and through the orifices with little or no impedance.
NASA Technical Reports Server (NTRS)
Anderson, John R.; Wilbur, Paul J.
1989-01-01
The potential usefulness of the constrained sheath optics concept as a means of controlling the divergence of low energy, high current density ion beams is examined numerically and experimentally. Numerical results demonstrate that some control of the divergence of typical ion beamlets can be achieved at perveance levels of interest by contouring the surface of the constrained sheath properly. Experimental results demonstrate that a sheath can be constrained by a wire mesh attached to the screen plate of the ion optics system. The numerically predicted beamlet divergence characteristics are shown to depart from those measured experimentally, and additional numerical analysis is used to demonstrate that this departure is probably due to distortions of the sheath caused by the fact that it attempts to conform to the individual wires that make up the sheath constraining mesh. The concept is considered potentially useful in controlling the divergence of ion beamlets in applications where low divergence, low energy, high current density beamlets are being sought, but more work is required to demonstrate this for net beam ion energies as low as 5 eV.
Li, Qingling; Liu, Dali; Xu, Lin; Xing, Ruiqing; Liu, Wei; Sheng, Kuang; Song, Hongwei
2015-10-14
A sensitive, label-free immunosensor based on iridium oxide (IrOx, 0≤x≤2) nanofibers, which were synthesized through a simple one-spinneret electrospinning method, was first developed for immunoassay of the cancer biomarker α-fetoprotein (AFP). The specific wire-in-tube nanostructure could be obtained and the composition of IrOx nanofibers also could be controlled through changing the annealing temperature. The unique structure and properties of IrOx nanofibers obtained at 500 °C not only led to increased electrode surface area and accelerated electron transfer kinetics but also could provide a highly stable matrix for the convenient conjugation of biomolecules together with chitosan (CS). The good electrochemical properties of the IrOx-nanofiber-modified immunosensor allowed one to detect AFP over a wide concentration range from 0.05 to 150 ng/mL, with a detection limit of 20 pg/mL. The proposed immunosensor also has been used to determine AFP in human serum with satisfactory results. The present protocol was shown to be quite promising for clinical screening of cancer biomarkers and point-of-care diagnostics applications.
Combined Volar Hamate Dislocation and Scapholunate Ligament Rupture: A Case Report.
Walmsley, David; Dhotar, Herman; Geddes, Christopher; Axelrod, Terry
2015-04-22
A twenty-two-year-old male patient presented to our trauma center after a motor-vehicle accident in which he sustained multiple injuries, including a volar dislocation of the hamate and ipsilateral scapholunate dissociation. Following closed reduction of the hamate dislocation, open reduction and stabilization of these carpal injuries was undertaken two days post-injury via a dorsal approach. Percutaneous Kirschner wires were used as well as two mini suture anchors to repair the scapholunate ligament. The patient was immobilized for six weeks and Kirschner wires were removed at twelve weeks postoperatively. To our knowledge, hamate dislocation with scapholunate dissociation and its surgical treatment have not previously been described. Successful surgical treatment for this injury pattern may be performed dorsally via direct reduction and repair of the scapholunate ligament with percutaneous pinning of the affected carpal bones.
Plasmonic mode converter for controlling optical impedance and nanoscale light-matter interaction.
Hung, Yun-Ting; Huang, Chen-Bin; Huang, Jer-Shing
2012-08-27
To enable multiple functions of plasmonic nanocircuits, it is of key importance to control the propagation properties and the modal distribution of the guided optical modes such that their impedance matches to that of nearby quantum systems and desired light-matter interaction can be achieved. Here, we present efficient mode converters for manipulating guided modes on a plasmonic two-wire transmission line. The mode conversion is achieved through varying the path length, wire cross section and the surrounding index of refraction. Instead of pure optical interference, strong near-field coupling of surface plasmons results in great momentum splitting and modal profile variation. We theoretically demonstrate control over nanoantenna radiation and discuss the possibility to enhance nanoscale light-matter interaction. The proposed converter may find applications in surface plasmon amplification, index sensing and enhanced nanoscale spectroscopy.
Advancement of Analysis Method for Electromagnetic Screening Effect of Mountain Tunnel
NASA Astrophysics Data System (ADS)
Okutani, Tamio; Nakamura, Nobuyuki; Terada, Natsuki; Fukuda, Mitsuyoshi; Tate, Yutaka; Inada, Satoshi; Itoh, Hidenori; Wakao, Shinji
In this paper we report advancement of an analysis method for electromagnetic screening effect of mountain tunnel with a multiple conductor circuit model. On A.C. electrified railways it is a great issue to manage the influence of electromagnetic induction caused by feeding circuits. Tunnels are said to have a screening effect to reduce the electromagnetic induction because a large amount of steel is used in the tunnels. But recently the screening effect is less expected because New Austrian Tunneling Method (NATM), in which the amount of steel used is less than in conventional methods, is adopted as the standard tunneling method for constructing mountain tunnels. So we measured and analyzed the actual screening effect of mountain tunnels constructed with NATM. In the process of the analysis we have advanced a method to analyze the screening effect more precisely. In this method we can adequately model tunnel structure as a part of multiple conductor circuit.
Electron-phonon interactions in semiconductor nanostructures
NASA Astrophysics Data System (ADS)
Yu, Segi
In this dissertation, electron-phonon interactions are studied theoretically in semiconductor nanoscale heterostructures. Interactions of electrons with interface optical phonons dominate over other electron-phonon interactions in narrow width heterostructures. Hence, a transfer matrix method is used to establish a formalism for determining the dispersion relations and electrostatic potentials of the interface phonons for multiple-interface heterostructure within the macroscopic dielectric continuum model. This method facilitates systematic calculations for complex structures where the conventional method is difficult to implement. Several specific cases are treated to illustrate advantages of the formalism. Electrophonon resonance (EPR) is studied in cylindrical quantum wires using the confined/interface optical phonons representation and bulk phonon representation. It has been found that interface phonon contribution to EPR is small compared with confined phonon. Different selection rules for bulk phonons and confined phonons result in different EPR behaviors as the radius of cylindrical wire changes. Experiment is suggested to test which phonon representation is appropriate for EPR. The effects of phonon confinement on elect ron-acoustic-phonon scattering is studied in cylindrical and rectangular quantum wires. In the macroscopic elastic continuum model, the confined-phonon dispersion relations are obtained for several crystallographic directions with free-surface and clamped-surface boundary conditions in cylindrical wires. The scattering rates due to the deformation potential are obtained for these confined phonons and are compared with those of bulk-like phonons. The results show that the inclusion of acoustic phonon confinement may be crucial for calculating accurate low-energy electron scattering rates. Furthermore, it has been found that there is a scaling rule governing the directional dependence of the scattering rates. The Hamiltonian describing the deformation-potential of confined acoustic phonons is derived by quantizing the appropriate, experimentally verified approximate compressional acoustic-phonon modes in a free-standing rectangular quantum wire. The scattering rate is obtained for GaAs quantum wires with a range of cross-sectional dimensions. The results demonstrate that a proper treatment of confined acoustic phonons may be essential to correctly model electron scattering rates at low energies in nanoscale structures.
2011-01-01
Background Screen-viewing has been associated with increased body mass, increased risk of metabolic syndrome and lower psychological well-being among children and adolescents. There is a shortage of information about the nature of contemporary screen-viewing amongst children especially given the rapid advances in screen-viewing equipment technology and their widespread availability. Anecdotal evidence suggests that large numbers of children embrace the multi-functionality of current devices to engage in multiple forms of screen-viewing at the same time. In this paper we used qualitative methods to assess the nature and extent of multiple forms of screen-viewing in UK children. Methods Focus groups were conducted with 10-11 year old children (n = 63) who were recruited from five primary schools in Bristol, UK. Topics included the types of screen-viewing in which the participants engaged; whether the participants ever engaged in more than one form of screen-viewing at any time and if so the nature of this multiple viewing; reasons for engaging in multi-screen-viewing; the room within the house where multi-screen-viewing took place and the reasons for selecting that room. All focus groups were transcribed verbatim, anonymised and thematically analysed. Results Multi-screen viewing was a common behaviour. Although multi-screen viewing often involved watching TV, TV viewing was often the background behaviour with attention focussed towards a laptop, handheld device or smart-phone. There were three main reasons for engaging in multi-screen viewing: 1) tempering impatience that was associated with a programme loading; 2) multi-screen facilitated filtering out unwanted content such as advertisements; and 3) multi-screen viewing was perceived to be enjoyable. Multi-screen viewing occurred either in the child's bedroom or in the main living area of the home. There was considerable variability in the level and timing of viewing and this appeared to be a function of whether the participants attended after-school clubs. Conclusions UK children regularly engage in two or more forms of screen-viewing at the same time. There are currently no means of assessing multi-screen viewing nor any interventions that specifically focus on reducing multi-screen viewing. To reduce children's overall screen-viewing we need to understand and then develop approaches to reduce multi-screen viewing among children. PMID:21812945
Jago, Russell; Sebire, Simon J; Gorely, Trish; Cillero, Itziar Hoyos; Biddle, Stuart J H
2011-08-03
Screen-viewing has been associated with increased body mass, increased risk of metabolic syndrome and lower psychological well-being among children and adolescents. There is a shortage of information about the nature of contemporary screen-viewing amongst children especially given the rapid advances in screen-viewing equipment technology and their widespread availability. Anecdotal evidence suggests that large numbers of children embrace the multi-functionality of current devices to engage in multiple forms of screen-viewing at the same time. In this paper we used qualitative methods to assess the nature and extent of multiple forms of screen-viewing in UK children. Focus groups were conducted with 10-11 year old children (n = 63) who were recruited from five primary schools in Bristol, UK. Topics included the types of screen-viewing in which the participants engaged; whether the participants ever engaged in more than one form of screen-viewing at any time and if so the nature of this multiple viewing; reasons for engaging in multi-screen-viewing; the room within the house where multi-screen-viewing took place and the reasons for selecting that room. All focus groups were transcribed verbatim, anonymised and thematically analysed. Multi-screen viewing was a common behaviour. Although multi-screen viewing often involved watching TV, TV viewing was often the background behaviour with attention focussed towards a laptop, handheld device or smart-phone. There were three main reasons for engaging in multi-screen viewing: 1) tempering impatience that was associated with a programme loading; 2) multi-screen facilitated filtering out unwanted content such as advertisements; and 3) multi-screen viewing was perceived to be enjoyable. Multi-screen viewing occurred either in the child's bedroom or in the main living area of the home. There was considerable variability in the level and timing of viewing and this appeared to be a function of whether the participants attended after-school clubs. UK children regularly engage in two or more forms of screen-viewing at the same time. There are currently no means of assessing multi-screen viewing nor any interventions that specifically focus on reducing multi-screen viewing. To reduce children's overall screen-viewing we need to understand and then develop approaches to reduce multi-screen viewing among children.
De Jesus, Maria; Sprunck-Harrild, Kim M.; Tellez, Trinidad; Bastani, Roshan; Battaglia, Tracy A.; Michaelson, James S.; Emmons, Karen M.
2014-01-01
Introduction Cancer screening rates among Latinas are suboptimal. The objective of this study was to explore how Latinas perceive cancer screening and the use and design of interactive voice response (IVR) messages to prompt scheduling of 1 or more needed screenings. Methods Seven focus groups were conducted with Latina community health center patients (n = 40) in need of 1 or more cancer screenings: 5 groups were of women in need of 1 cancer screening (breast, cervical, or colorectal), and 2 groups were of women in need of multiple screenings. A bilingual researcher conducted all focus groups in Spanish using a semistructured guide. Focus groups were recorded, transcribed, and translated into English for analysis. Emergent themes were identified by using thematic content analysis. Results Participants were familiar with cancer screening and viewed it positively, although barriers to screening were identified (unaware overdue for screening, lack of physician referral, lack of insurance or insufficient insurance coverage, embarrassment or fear of screening procedures, fear of screening outcomes). Women needing multiple screenings voiced more concern about screening procedures, whereas women in need of a single screening expressed greater worry about the screening outcome. Participants were receptive to receiving IVR messages and believed that culturally appropriate messages that specified needed screenings while emphasizing the benefit of preventive screening would motivate them to schedule needed screenings. Conclusion Participants’ receptiveness to IVR messages suggests that these messages may be an acceptable strategy to promote cancer screening among underserved Latina patients. Additional research is needed to determine the effectiveness of IVR messages in promoting completion of cancer screening. PMID:24625364
Peng, Sean X; Cousineau, Martin; Juzwin, Stephen J; Ritchie, David M
2006-01-01
A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples--to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.
Havas, Magda
2006-01-01
Dirty electricity is a ubiquitous pollutant. It flows along wires and radiates from them and involves both extremely low frequency electromagnetic fields and radio frequency radiation. Until recently, dirty electricity has been largely ignored by the scientific community. Recent inventions of metering and filter equipment provide scientists with the tools to measure and reduce dirty electricity on electrical wires. Several case studies and anecdotal reports are presented. Graham/Stetzer (GS) filters have been installed in schools with sick building syndrome and both staff and students reported improved health and more energy. The number of students needing inhalers for asthma was reduced in one school and student behavior associated with ADD/ADHD improved in another school. Blood sugar levels for some diabetics respond to the amount of dirty electricity in their environment. Type 1 diabetics require less insulin and Type 2 diabetics have lower blood sugar levels in an electromagnetically clean environment. Individuals diagnosed with multiple sclerosis have better balance and fewer tremors. Those requiring a cane walked unassisted within a few days to weeks after GS filters were installed in their home. Several disorders, including asthma, ADD/ADHD, diabetes, multiple sclerosis, chronic fatigue, fibromyalgia, are increasing at an alarming rate, as is electromagnetic pollution in the form of dirty electricity, ground current, and radio frequency radiation from wireless devices. The connection between electromagnetic pollution and these disorders needs to be investigated and the percentage of people sensitive to this form of energy needs to be determined.
Quantifying and resolving multiple vector transformants in S. cerevisiae plasmid libraries.
Scanlon, Thomas C; Gray, Elizabeth C; Griswold, Karl E
2009-11-20
In addition to providing the molecular machinery for transcription and translation, recombinant microbial expression hosts maintain the critical genotype-phenotype link that is essential for high throughput screening and recovery of proteins encoded by plasmid libraries. It is known that Escherichia coli cells can be simultaneously transformed with multiple unique plasmids and thusly complicate recombinant library screening experiments. As a result of their potential to yield misleading results, bacterial multiple vector transformants have been thoroughly characterized in previous model studies. In contrast to bacterial systems, there is little quantitative information available regarding multiple vector transformants in yeast. Saccharomyces cerevisiae is the most widely used eukaryotic platform for cell surface display, combinatorial protein engineering, and other recombinant library screens. In order to characterize the extent and nature of multiple vector transformants in this important host, plasmid-born gene libraries constructed by yeast homologous recombination were analyzed by DNA sequencing. It was found that up to 90% of clones in yeast homologous recombination libraries may be multiple vector transformants, that on average these clones bear four or more unique mutant genes, and that these multiple vector cells persist as a significant proportion of library populations for greater than 24 hours during liquid outgrowth. Both vector concentration and vector to insert ratio influenced the library proportion of multiple vector transformants, but their population frequency was independent of transformation efficiency. Interestingly, the average number of plasmids born by multiple vector transformants did not vary with their library population proportion. These results highlight the potential for multiple vector transformants to dominate yeast libraries constructed by homologous recombination. The previously unrecognized prevalence and persistence of multiply transformed yeast cells have important implications for yeast library screens. The quantitative information described herein should increase awareness of this issue, and the rapid sequencing approach developed for these studies should be widely useful for identifying multiple vector transformants and avoiding complications associated with cells that have acquired more than one unique plasmid.
An investigation of nonsimultaneous laser-induced fluorescence
NASA Technical Reports Server (NTRS)
Fletcher, D. G.
1993-01-01
An alternative to simultaneous, two-line laser-induced fluorescence for thermodynamic property measurement is presented. This spectroscopic approach is similar to multiple-overheat hot-wire anemometry and is based on laser excitation of different fluorescence transitions for separate, sequential wind tunnel runs. Both fluctuating and mean thermodynamic property measurements seem to be achievable with this method without exciting the transitions during the same laser pulse.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 75.1003 Section 75.1003... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trolley Wires and Trolley Feeder Wires § 75.1003...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 75.1003 Section 75.1003... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trolley Wires and Trolley Feeder Wires § 75.1003...
Stability test and analysis of the Space Shuttle Primary Reaction Control Subsystem thruster
NASA Technical Reports Server (NTRS)
Applewhite, John; Hurlbert, Eric; Krohn, Douglas; Arndt, Scott; Clark, Robert
1992-01-01
The results are reported of a test program conducted on the Space Shuttle Primary Reaction Control Subsystem thruster in order to investigate the effects of trapped helium bubbles and saturated propellants on stability, determine if thruster-to-thruster stability variations are significant, and determine stability under STS-representative conditions. It is concluded that the thruster design is highly reliable in flight and that burn-through has not occurred. Significantly unstable thrusters are screened out, and wire wrap is found to protect against chamber burn-throughs and to provide a fail-safe thruster for this situation.
The state of the art of conventional flow visualization techniques for wind tunnel testing
NASA Technical Reports Server (NTRS)
Settles, G. S.
1982-01-01
Conventional wind tunnel flow visualization techniques which consist of surface flow methods, tracers, and optical methods are presented. Different surface flow methods are outlined: (1) liquid films (oil and fluorescent dye and UV lighting, renewable film via porous dispenser in model, volatile carrier fluid, cryogenic colored oil dots, oil film interferometry); (2) reactive surface treatment (reactive gas injection, reversible dye); (3) transition and heat transfer detectors (evaporation, sublimation, liquid crystals, phase change paints, IR thermography); and (4) tufts (fluorescent mini tufts, cryogenic suitability). Other methods are smoke wire techniques, vapor screens, and optical methods.
Dual wire welding torch and method
Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.
2009-04-28
A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.
Sun, Guanghao; Nakayama, Yosuke; Dagdanpurev, Sumiyakhand; Abe, Shigeto; Nishimura, Hidekazu; Kirimoto, Tetsuo; Matsui, Takemi
2017-02-01
Infrared thermography (IRT) is used to screen febrile passengers at international airports, but it suffers from low sensitivity. This study explored the application of a combined visible and thermal image processing approach that uses a CMOS camera equipped with IRT to remotely sense multiple vital signs and screen patients with suspected infectious diseases. An IRT system that produced visible and thermal images was used for image acquisition. The subjects' respiration rates were measured by monitoring temperature changes around the nasal areas on thermal images; facial skin temperatures were measured simultaneously. Facial blood circulation causes tiny color changes in visible facial images that enable the determination of the heart rate. A logistic regression discriminant function predicted the likelihood of infection within 10s, based on the measured vital signs. Sixteen patients with an influenza-like illness and 22 control subjects participated in a clinical test at a clinic in Fukushima, Japan. The vital-sign-based IRT screening system had a sensitivity of 87.5% and a negative predictive value of 91.7%; these values are higher than those of conventional fever-based screening approaches. Multiple vital-sign-based screening efficiently detected patients with suspected infectious diseases. It offers a promising alternative to conventional fever-based screening. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Daghighi, Yasaman; Heidari, Hossein; Taylor, Hayden
2018-02-01
A predominant unsolved challenge in tissue engineering is the need of a robust technique for producing vascular networks, particularly when modeling human brain tissue. The availability of reliable in vitro human brain microvasculature models would advance our understanding of its function and would provide a platform for highthroughput drug screening. Current strategies for modeling vascularized brain tissue suffer from limitations such as (1) culturing non-human cell lines, (2) limited multi-cell co-culture, and (3) the effects of neighboring physiologically unrealistic rigid polymeric surfaces, such as solid membranes. We demonstrate a new micro-engineered platform that can address these shortcomings. Specifically, we have designed and prototyped a molding system to enable the precise casting of 100μm-diameter coaxial hydrogel structures laden with the requisite cells to mimic a vascular lumen. Here we demonstrate that a fine wire with diameter 130 μm or a needle with outer diameter 300 μm can be used as a temporary mold insert, and agarose-collagen composite matrix can be cast around these inserts and thermally gelled. When the wire or needle is retracted under the precise positional control afforded by our system, a microchannel is formed which is then seeded with human microvascular endothelial cells. After seven days of culture these cells produce an apparently confluent monolayer on the channel walls. In principle, this platform could be used to create multilayered cellular structures. By arranging a fine wire and a hollow needle coaxially, three distinct zones could be defined in the model: first, the bulk gel surrounding the needle; then, after needle retraction, a cylindrical shell of matrix; and finally, after retraction of the wire, a lumen. Each zone could be independently cell-seeded. To this end, we have also successfully 3D cultured human astrocytes and SY5Y glial cells in our agarose-collagen matrix. Our approach ultimately promises scalable and repeatable production of vascular structures with physiologically realistic mechanical properties.
ERIC Educational Resources Information Center
Sprague, Sheila; Madden, Kim; Dosanjh, Sonia; Petrisor, Brad; Schemitsch, Emil H.; Bhandari, Mohit
2012-01-01
Accurately identifying victims of intimate partner violence (IPV) can be a challenge for clinicians and clinical researchers. Multiple instruments have been developed and validated to identify IPV in patients presenting to health care practitioners, including the Woman Abuse Screening Tool (WAST) and the Partner Violence Screen (PVS). The purpose…
NASA Astrophysics Data System (ADS)
Tsai, Tsung-Ying; Chang, Kai-Wei; Chen, Calvin Yu-Chian
2011-06-01
The rapidly advancing researches on traditional Chinese medicine (TCM) have greatly intrigued pharmaceutical industries worldwide. To take initiative in the next generation of drug development, we constructed a cloud-computing system for TCM intelligent screening system (iScreen) based on TCM Database@Taiwan. iScreen is compacted web server for TCM docking and followed by customized de novo drug design. We further implemented a protein preparation tool that both extract protein of interest from a raw input file and estimate the size of ligand bind site. In addition, iScreen is designed in user-friendly graphic interface for users who have less experience with the command line systems. For customized docking, multiple docking services, including standard, in-water, pH environment, and flexible docking modes are implemented. Users can download first 200 TCM compounds of best docking results. For TCM de novo drug design, iScreen provides multiple molecular descriptors for a user's interest. iScreen is the world's first web server that employs world's largest TCM database for virtual screening and de novo drug design. We believe our web server can lead TCM research to a new era of drug development. The TCM docking and screening server is available at http://iScreen.cmu.edu.tw/.
Tsai, Tsung-Ying; Chang, Kai-Wei; Chen, Calvin Yu-Chian
2011-06-01
The rapidly advancing researches on traditional Chinese medicine (TCM) have greatly intrigued pharmaceutical industries worldwide. To take initiative in the next generation of drug development, we constructed a cloud-computing system for TCM intelligent screening system (iScreen) based on TCM Database@Taiwan. iScreen is compacted web server for TCM docking and followed by customized de novo drug design. We further implemented a protein preparation tool that both extract protein of interest from a raw input file and estimate the size of ligand bind site. In addition, iScreen is designed in user-friendly graphic interface for users who have less experience with the command line systems. For customized docking, multiple docking services, including standard, in-water, pH environment, and flexible docking modes are implemented. Users can download first 200 TCM compounds of best docking results. For TCM de novo drug design, iScreen provides multiple molecular descriptors for a user's interest. iScreen is the world's first web server that employs world's largest TCM database for virtual screening and de novo drug design. We believe our web server can lead TCM research to a new era of drug development. The TCM docking and screening server is available at http://iScreen.cmu.edu.tw/.
Lindén, Rolf O; Eronen, Ville-Pekka; Aittokallio, Tero
2011-03-24
High-throughput genetic screening approaches have enabled systematic means to study how interactions among gene mutations contribute to quantitative fitness phenotypes, with the aim of providing insights into the functional wiring diagrams of genetic interaction networks on a global scale. However, it is poorly known how well these quantitative interaction measurements agree across the screening approaches, which hinders their integrated use toward improving the coverage and quality of the genetic interaction maps in yeast and other organisms. Using large-scale data matrices from epistatic miniarray profiling (E-MAP), genetic interaction mapping (GIM), and synthetic genetic array (SGA) approaches, we carried out here a systematic comparative evaluation among these quantitative maps of genetic interactions in yeast. The relatively low association between the original interaction measurements or their customized scores could be improved using a matrix-based modelling framework, which enables the use of single- and double-mutant fitness estimates and measurements, respectively, when scoring genetic interactions. Toward an integrative analysis, we show how the detections from the different screening approaches can be combined to suggest novel positive and negative interactions which are complementary to those obtained using any single screening approach alone. The matrix approximation procedure has been made available to support the design and analysis of the future screening studies. We have shown here that even if the correlation between the currently available quantitative genetic interaction maps in yeast is relatively low, their comparability can be improved by means of our computational matrix approximation procedure, which will enable integrative analysis and detection of a wider spectrum of genetic interactions using data from the complementary screening approaches.
ERIC Educational Resources Information Center
Dowdy, Erin; Dever, Bridget V.; Raines, Tara C.; Moffa, Kathryn
2016-01-01
Mental health screening in schools is a progressive practice to identify students for prevention and intervention services. Multiple gating procedures, in which students are provided more intensive assessments following initial identification of risk, are aligned with prevention science and poised to enhance multi-tiered systems of support. Yet,…
Mazoure, Bogdan; Caraus, Iurie; Nadon, Robert; Makarenkov, Vladimir
2018-06-01
Data generated by high-throughput screening (HTS) technologies are prone to spatial bias. Traditionally, bias correction methods used in HTS assume either a simple additive or, more recently, a simple multiplicative spatial bias model. These models do not, however, always provide an accurate correction of measurements in wells located at the intersection of rows and columns affected by spatial bias. The measurements in these wells depend on the nature of interaction between the involved biases. Here, we propose two novel additive and two novel multiplicative spatial bias models accounting for different types of bias interactions. We describe a statistical procedure that allows for detecting and removing different types of additive and multiplicative spatial biases from multiwell plates. We show how this procedure can be applied by analyzing data generated by the four HTS technologies (homogeneous, microorganism, cell-based, and gene expression HTS), the three high-content screening (HCS) technologies (area, intensity, and cell-count HCS), and the only small-molecule microarray technology available in the ChemBank small-molecule screening database. The proposed methods are included in the AssayCorrector program, implemented in R, and available on CRAN.
Preliminary Experience with use of Qureshi-5 Catheters for Diagnostic Cerebral Angiography
Qureshi, Adnan I.; Yan, Xiao; Liu, HongLiang
2015-01-01
BACKGROUND A catheter technique was developed to overcome current challenges in the stabilization and manipulation of catheter in tortuous arteries such as right subclavian artery and left common carotid artery. METHODS The new catheter has the following two lumens: first lumen can accommodate a 0.035-inch guide wire (lumen A) and a curved shape at the distal end; the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen (lumen B). The catheter is withdrawn or advanced over the 0.018-inch guide wire and the curved free end of catheter manipulated until the end engages the origin of the target artery. Subsequently, either contrast can be injected or a 0.035-inch guide wire advanced into the target artery. RESULTS The catheters were used in two patients to perform diagnostic cerebral angiography through a 6F introducer sheath placed in the right common femoral artery. The left and right common carotid arteries and left and right vertebral arteries were catheterized in first patient (contrast used 50 ml; fluoroscopy time 20:09 min). The left and right internal carotid arteries, left and right subclavian arteries, and left external carotid artery were catheterized in second patient (contrast used 40 ml; fluoroscopy time 13:56 min). No complications were observed in either of the two patients. CONCLUSIONS The performance of the new catheter for catheterization of multiple arteries in two patients was considered adequate with high-quality angiographic image acquisitions. PMID:26060529
Lopes, Hélio P; Gambarra-Soares, Thaiane; Elias, Carlos N; Siqueira, José F; Inojosa, Inês F J; Lopes, Weber S P; Vieira, Victor T L
2013-04-01
This study compared the mechanical properties of endodontic instruments made of conventional nickel-titanium (NiTi) wire (K(3) and Revo-S SU), M-Wire (ProFile Vortex), or NiTi alloy in R-phase (K(3)XF). The test instruments were subjected to mechanical tests to evaluate resistance to bending (flexibility), cyclic fatigue, and torsional load in clockwise rotation. Data were statistically evaluated by the analysis of variance test and the Student-Newman-Keuls test for multiple comparisons. In the bending resistance test, flexibility decreased in the following order: K(3)XF > Revo-S SU > ProFile Vortex > K(3). The ranking in the fatigue resistance test was the following: K(3)XF > K(3) > ProFile Vortex > Revo-S SU. In the torsional assay, the angular deflection at failure decreased in the following order: K(3)XF > Revo-S SU > K(3) > ProFile Vortex. For the maximum torque values, the ranking was K(3) > K(3)XF > ProFile Vortex > Revo-S SU. The results showed that the K(3)XF instrument, which is made of NiTi alloy in R-phase, had the overall best performance in terms of flexibility, angular deflection at failure, and cyclic fatigue resistance. In addition to the alloy from which the instrument is manufactured, the design and dimensions are important determinants of the mechanical performance of endodontic instruments. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Fabrication of a Kilopixel Array of Superconducting Microcalorimeters with Microstripline Wiring
NASA Technical Reports Server (NTRS)
Chervenak, James
2012-01-01
A document describes the fabrication of a two-dimensional microcalorimeter array that uses microstrip wiring and integrated heat sinking to enable use of high-performance pixel designs at kilopixel scales (32 X 32). Each pixel is the high-resolution design employed in small-array test devices, which consist of a Mo/Au TES (transition edge sensor) on a silicon nitride membrane and an electroplated Bi/Au absorber. The pixel pitch within the array is 300 microns, where absorbers 290 microns on a side are cantilevered over a silicon support grid with 100-micron-wide beams. The high-density wiring and heat sinking are both carried by the silicon beams to the edge of the array. All pixels are wired out to the array edge. ECR (electron cyclotron resonance) oxide underlayer is deposited underneath the sensor layer. The sensor (TES) layer consists of a superconducting underlayer and a normal metal top layer. If the sensor is deposited at high temperature, the ECR oxide can be vacuum annealed to improve film smoothness and etch characteristics. This process is designed to recover high-resolution, single-pixel x-ray microcalorimeter performance within arrays of arbitrarily large format. The critical current limiting parts of the circuit are designed to have simple interfaces that can be independently verified. The lead-to-TES interface is entirely determined in a single layer that has multiple points of interface to maximize critical current. The lead rails that overlap the TES sensor element contact both the superconducting underlayer and the TES normal metal
Talamo, Giampaolo P; Ibrahim, Sulfi; Claxton, David; Tricot, Guido J; Fink, Louis M; Zangari, Maurizio
2009-07-01
The therapeutic use of thalidomide in patients with multiple myeloma is often complicated by the development of venous thromboembolism. The objective of the present study was to identify hypercoagulable states associated with development of venous thromboembolism in thalidomide-treated multiple myeloma patients. We screened 49 consecutive multiple myeloma patients treated with thalidomide at baseline for hypercoagulability. With a median follow-up of 11 months, 10 of 49 multiple myeloma patients developed a thrombotic episode. Laboratory assays revealed an underlying abnormality in nine of the 10 patients; hypercoagulable screenings were normal in 36 of the 39 patients who did not develop venous thromboembolism (P < 0.0001). Our retrospective study results suggest that the multiple myeloma patients with thromboembolic complications during treatment with thalidomide have a frequent concomitant underlying thrombophilic state.
Multilayer self-organization of InGaAs quantum wires on GaAs surfaces
NASA Astrophysics Data System (ADS)
Wang, Zhiming M.; Kunets, Vasyl P.; Xie, Yanze Z.; Schmidbauer, Martin; Dorogan, Vitaliy G.; Mazur, Yuriy I.; Salamo, Gregory J.
2010-12-01
Molecular-Beam Epitaxy growth of multiple In 0.4Ga 0.6As layers on GaAs (311)A and GaAs (331)A has been investigated by Atomic Force Microscopy and Photoluminescence. On GaAs (311)A, uniformly distributed In 0.4Ga 0.6As quantum wires (QWRs) with wider lateral separation were achieved, presenting a significant improvement in comparison with the result on single layer [H. Wen, Z.M. Wang, G.J. Salamo, Appl. Phys. Lett. 84 (2004) 1756]. On GaAs (331)A, In 0.4Ga 0.6As QWRs were revealed to be much straighter than in the previous report on multilayer growth [Z. Gong, Z. Niu, Z. Fang, Nanotechnology 17 (2006) 1140]. These observations are discussed in terms of the strain-field interaction among multilayers, enhancement of surface mobility at high temperature, and surface stability of GaAs (311)A and (331)A surfaces.
Interconnect-free parallel logic circuits in a single mechanical resonator
Mahboob, I.; Flurin, E.; Nishiguchi, K.; Fujiwara, A.; Yamaguchi, H.
2011-01-01
In conventional computers, wiring between transistors is required to enable the execution of Boolean logic functions. This has resulted in processors in which billions of transistors are physically interconnected, which limits integration densities, gives rise to huge power consumption and restricts processing speeds. A method to eliminate wiring amongst transistors by condensing Boolean logic into a single active element is thus highly desirable. Here, we demonstrate a novel logic architecture using only a single electromechanical parametric resonator into which multiple channels of binary information are encoded as mechanical oscillations at different frequencies. The parametric resonator can mix these channels, resulting in new mechanical oscillation states that enable the construction of AND, OR and XOR logic gates as well as multibit logic circuits. Moreover, the mechanical logic gates and circuits can be executed simultaneously, giving rise to the prospect of a parallel logic processor in just a single mechanical resonator. PMID:21326230
Interconnect-free parallel logic circuits in a single mechanical resonator.
Mahboob, I; Flurin, E; Nishiguchi, K; Fujiwara, A; Yamaguchi, H
2011-02-15
In conventional computers, wiring between transistors is required to enable the execution of Boolean logic functions. This has resulted in processors in which billions of transistors are physically interconnected, which limits integration densities, gives rise to huge power consumption and restricts processing speeds. A method to eliminate wiring amongst transistors by condensing Boolean logic into a single active element is thus highly desirable. Here, we demonstrate a novel logic architecture using only a single electromechanical parametric resonator into which multiple channels of binary information are encoded as mechanical oscillations at different frequencies. The parametric resonator can mix these channels, resulting in new mechanical oscillation states that enable the construction of AND, OR and XOR logic gates as well as multibit logic circuits. Moreover, the mechanical logic gates and circuits can be executed simultaneously, giving rise to the prospect of a parallel logic processor in just a single mechanical resonator.
Extracellular wire tetrode recording in brain of freely walking insects.
Guo, Peiyuan; Pollack, Alan J; Varga, Adrienn G; Martin, Joshua P; Ritzmann, Roy E
2014-04-01
Increasing interest in the role of brain activity in insect motor control requires that we be able to monitor neural activity while insects perform natural behavior. We previously developed a technique for implanting tetrode wires into the central complex of cockroach brains that allowed us to record activity from multiple neurons simultaneously while a tethered cockroach turned or altered walking speed. While a major advance, tethered preparations provide access to limited behaviors and often lack feedback processes that occur in freely moving animals. We now present a modified version of that technique that allows us to record from the central complex of freely moving cockroaches as they walk in an arena and deal with barriers by turning, climbing or tunneling. Coupled with high speed video and cluster cutting, we can now relate brain activity to various parameters of the movement of freely behaving insects.
System for phase-contrast x-ray radiography using X pinch radiation and a method thereof
Chandler, Katherine; Chelkovenko, Tatiana; Hammer, David; Pikuz, Sergei; Sinars, Daniel; Song, Byungmoo
2007-11-06
A radiograph system with an anode plate, a cathode plate, and a power source coupled to said anode plate and the cathode plate. At least two wires coupled between the anode plate and the cathode plate provide a configuration to form an X-pinch having a photon source size of less than five microns at energies above 2.5 keV. Material at the configuration forming the X-pinch vaporizes upon application of a suitable current to the wires forming a dense hot plasma and emitting a single x-ray pulse with sufficient photons having energies in the range of from about 2.5 keV to about 20 keV to provide a phase contrast image of an object in the path of the photons. Multiple simultaneous images may be formed of a plurality of objects. Suitable filters and x-ray detectors are provided.
Reliability Criteria for Thick Bonding Wire.
Dagdelen, Turker; Abdel-Rahman, Eihab; Yavuz, Mustafa
2018-04-17
Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire.
Reliability Criteria for Thick Bonding Wire
Yavuz, Mustafa
2018-01-01
Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire. PMID:29673194
Skeletal Fixation in a Mutilated Hand.
Bhardwaj, Praveen; Sankaran, Ajeesh; Sabapathy, S Raja
2016-11-01
Hand fracture fixation in mutilating injuries is characterized by multiple challenges due to possible skeletal disorganization and concomitant severe injury of soft tissue structures. The effects of skeletal disruption are best analyzed as divided into specific locales in the hand: radial, ulnar, proximal, and distal. Functional consequences of injuries in each of these regions are discussed. Although a variety of implants are now in vogue, K-wire fixation has stood the test of time and is especially useful in multiple fracture situations. Segmental bone loss is quite common in such injuries, which can be safely reconstructed in a staged manner. Copyright © 2016 Elsevier Inc. All rights reserved.
GBLD10+: a compact low-power 10 Gb/s VCSEL driver
Zhang, T.; Kulis, S.; Gui, P.; ...
2016-01-13
We report the design and implementation of the GBLD10+, a low-power 10 Gb/s VCSEL driver for High Energy Physics (HEP) applications. With new circuit techniques, the driver consumes only 31 mW and occupies a small area of 400 μm × 1750 μm including the IO PADs and sealrings. These characteristics allow for multiple GBLD10+ ICs to be assembled side by side in a compact module, with each one directly wire bonded to one VCSEL diode. Finally, this makes the GBLD10+ a suitable candidate for the Versatile Link PLUS (VL +) project, offering flexibility in configuring multiple transmitters and receivers.
NASA Astrophysics Data System (ADS)
Kohl, M.; Heitmann, D.; Grambow, P.; Ploog, K.
1988-06-01
Periodic multiple-quantum-well wires have been prepared by etching five-layer quantum-well structures through a holographically prepared mask. The periodicity was 380 nm, the lateral confinement 180 nm, and the quantum-well width 13, nm. The luminescence from these microstructured systems in the frequency regime of the one-electron-one-heavy-hole transition was strongly polarized with the electric field perpendicular to the periodic structure. This effect was caused by the resonantly enhanced emission of quantum-well-exciton (QWE) polaritons. Excitation of QWE polaritons was also observed in reflection measurements on the microstructured samples.
NASA Technical Reports Server (NTRS)
Parrish, Clyde F. (Inventor)
2012-01-01
A self-healing system for an insulation material initiates a self-repair process by rupturing a plurality of microcapsules disposed on the insulation material. When the plurality of microcapsules are ruptured, reactants within the plurality of microcapsules react to form a replacement polymer in a break of the insulation material. This self-healing system has the ability to repair multiple breaks in a length of insulation material without exhausting the repair properties of the material.
30 CFR 75.1003-1 - Other requirements for guarding of trolley wires and trolley feeder wires.
Code of Federal Regulations, 2010 CFR
2010-07-01
... wires and trolley feeder wires. 75.1003-1 Section 75.1003-1 Mineral Resources MINE SAFETY AND HEALTH... Trolley Wires and Trolley Feeder Wires § 75.1003-1 Other requirements for guarding of trolley wires and trolley feeder wires. Adequate precaution shall be taken to insure that equipment being moved along...
30 CFR 75.1003-1 - Other requirements for guarding of trolley wires and trolley feeder wires.
Code of Federal Regulations, 2011 CFR
2011-07-01
... wires and trolley feeder wires. 75.1003-1 Section 75.1003-1 Mineral Resources MINE SAFETY AND HEALTH... Trolley Wires and Trolley Feeder Wires § 75.1003-1 Other requirements for guarding of trolley wires and trolley feeder wires. Adequate precaution shall be taken to insure that equipment being moved along...
The BetaCage, an ultra-sensitive screener for surface contamination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bunker, R.; Bowles, M. A.; Schnee, R. W.
Material screening for identifying low-energy electron emitters and alpha-decaying isotopes is now a prerequisite for rare-event searches (e.g., dark-matter direct detection and neutrinoless double-beta decay) for which surface radiocon-tamination has become an increasingly important background. The BetaCage, a gaseous neon time-projection chamber, is a proposed ultra-sensitive (and nondestructive) screener for alpha-and beta-emitting surface contaminants to which existing screening facilities are insufficiently sensitive. Sensitivity goals are 0.1 betas keV{sup −1} m{sup −2} day{sup −1} and 0.1 alphas m{sup −2} day{sup −1}, with the former limited by Compton scattering of photons in the screening samples and (thanks to tracking) the latter expectedmore » to be signal-limited; radioassays and simulations indicate backgrounds from detector materials and radon daughters should be subdominant. We report on details of the background simulations and detector design that provide the discrimination, shielding, and radiopurity necessary to reach our sensitivity goals for a chamber with a 95 × 95 cm{sup 2} sample area positioned below a 40 cm drift region and monitored by crisscrossed anode and cathode planes consisting of 151 wires each.« less
Ahadian, Samad; Ramón-Azcón, Javier; Ostrovidov, Serge; Camci-Unal, Gulden; Hosseini, Vahid; Kaji, Hirokazu; Ino, Kosuke; Shiku, Hitoshi; Khademhosseini, Ali; Matsue, Tomokazu
2012-09-21
Engineered skeletal muscle tissues could be useful for applications in tissue engineering, drug screening, and bio-robotics. It is well-known that skeletal muscle cells are able to differentiate under electrical stimulation (ES), with an increase in myosin production, along with the formation of myofibers and contractile proteins. In this study, we describe the use of an interdigitated array of electrodes as a novel platform to electrically stimulate engineered muscle tissues. The resulting muscle myofibers were analyzed and quantified in terms of their myotube characteristics and gene expression. The engineered muscle tissues stimulated through the interdigitated array of electrodes demonstrated superior performance and maturation compared to the corresponding tissues stimulated through a conventional setup (i.e., through Pt wires in close proximity to the muscle tissue). In particular, the ES of muscle tissue (voltage 6 V, frequency 1 Hz and duration 10 ms for 1 day) through the interdigitated array of electrodes resulted in a higher degree of C2C12 myotube alignment (∼80%) as compared to ES using Pt wires (∼65%). In addition, higher amounts of C2C12 myotube coverage area, myotube length, muscle transcription factors and protein biomarkers were found for myotubes stimulated through the interdigitated array of electrodes compared to those stimulated using the Pt wires. Due to the wide array of potential applications of ES for two- and three-dimensional (2D and 3D) engineered tissues, the suggested platform could be employed for a variety of cell and tissue structures to more efficiently investigate their response to electrical fields.
Chiang, Ann-Shyn; Lin, Chih-Yung; Chuang, Chao-Chun; Chang, Hsiu-Ming; Hsieh, Chang-Huain; Yeh, Chang-Wei; Shih, Chi-Tin; Wu, Jian-Jheng; Wang, Guo-Tzau; Chen, Yung-Chang; Wu, Cheng-Chi; Chen, Guan-Yu; Ching, Yu-Tai; Lee, Ping-Chang; Lin, Chih-Yang; Lin, Hui-Hao; Wu, Chia-Chou; Hsu, Hao-Wei; Huang, Yun-Ann; Chen, Jing-Yi; Chiang, Hsin-Jung; Lu, Chun-Fang; Ni, Ru-Fen; Yeh, Chao-Yuan; Hwang, Jenn-Kang
2011-01-11
Animal behavior is governed by the activity of interconnected brain circuits. Comprehensive brain wiring maps are thus needed in order to formulate hypotheses about information flow and also to guide genetic manipulations aimed at understanding how genes and circuits orchestrate complex behaviors. To assemble this map, we deconstructed the adult Drosophila brain into approximately 16,000 single neurons and reconstructed them into a common standardized framework to produce a virtual fly brain. We have constructed a mesoscopic map and found that it consists of 41 local processing units (LPUs), six hubs, and 58 tracts covering the whole Drosophila brain. Despite individual local variation, the architecture of the Drosophila brain shows invariance for both the aggregation of local neurons (LNs) within specific LPUs and for the connectivity of projection neurons (PNs) between the same set of LPUs. An open-access image database, named FlyCircuit, has been constructed for online data archiving, mining, analysis, and three-dimensional visualization of all single neurons, brain-wide LPUs, their wiring diagrams, and neural tracts. We found that the Drosophila brain is assembled from families of multiple LPUs and their interconnections. This provides an essential first step in the analysis of information processing within and between neurons in a complete brain. Copyright © 2011 Elsevier Ltd. All rights reserved.
Thomas, N.J.
1999-01-01
Power lines and power poles present a potential electrocution hazard to wild birds. Many birds, especially raptors, select power poles for perching, and, sometimes, for nesting (Figs. 50.1–3). If a bird’s appendages bridge the gap between two energized parts or between an energized and a grounded metal part, electricity flows through the “bridge” that is filling the gap and the bird is electrocuted. Most commonly, birds are electrocuted where conducting wires (conductors) are placed closer together than the wingspan of birds that frequent the poles (Fig. 50.2). Feathers are poor electrical conductors, but if contact is made between points on the skin, talons, or beak, or if the feathers are wet, conduction can occur. Common anatomical sites of contact include conduction between the wrists of each wing or between the skin of one wing and a foot or leg. The resulting shock causes severe, usually fatal, cardiovascular injury. Because conductors on distribution lines are placed closer together than high voltage transmission lines, birds are more frequently electrocuted on distribution lines despite their lower voltage. In addition to one to three conductors, power poles may also carry ground wires, transformers, or grounded metal crossarm braces. Complicated wiring configurations that put multiple energized and grounded metal parts near attractive perching or nesting sites are the most hazardous configurations (Fig. 50.3).
Kim, Yi-Soon; Kim, Min-Za; Jeong, Ihn-Sook
2004-08-01
This study was aimed to identify the effect of self-foot reflexology on the relief of premenstrual syndrome and dysmenorrhea in high school girls. Study subjects was 236 women residing in the community, teachers and nurses who were older than 45 were recruited. Data was collected with self administered questionnaires from July 1st to August 31st, 2003 and analysed using SPSS/WIN 10.0 with Xtest, t-test, and stepwise multiple logistic regression at a significant level of =.05. The breast cancer screening rate was 57.2%, and repeat screening rate was 15.3%. With the multiple logistic regression analysis, factors associated with mammography screening were age and perceived barriers of action, and factors related to the repeat mammography screening were education level and other cancer screening experience. Based on the results, we recommend the development of an intervention program to decrease the perceived barrier of action, to regard mammography as an essential test in regular check-up, and to give active advertisement and education to the public to improve the rates of breast cancer screening and repeat screening.
Electrically isolated, high melting point, metal wire arrays and method of making same
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpson, John T.; Cunningham, Joseph P.; D'Urso, Brian R.
2016-01-26
A method of making a wire array includes the step of providing a tube of a sealing material and having an interior surface, and positioning a wire in the tube, the wire having an exterior surface. The tube is heated to soften the tube, and the softened tube is drawn and collapsed by a mild vacuum to bring the interior surface of the tube into contact with the wire to create a coated wire. The coated wires are bundled. The bundled coated wires are heated under vacuum to fuse the tube material coating the wires and create a fused rodmore » with a wire array embedded therein. The fused rod is cut to form a wire array. A wire array is also disclosed.« less
ERIC Educational Resources Information Center
Danseco, Evangeline R.; Marques, Paul R.
2002-01-01
The Problem-Oriented Screening Instrument for Teenagers (POSIT) screens for multiple problems among adolescents at risk for substance use. A shortened version of the POSIT was developed, using factor analysis, and correlational and reliability analyses. The POSIT-SF shows potential for a reliable and cost-efficient screen for youth with substance…
49 CFR 234.241 - Protection of insulated wire; splice in underground wire.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Protection of insulated wire; splice in underground wire. 234.241 Section 234.241 Transportation Other Regulations Relating to Transportation... of insulated wire; splice in underground wire. Insulated wire shall be protected from mechanical...
49 CFR 234.241 - Protection of insulated wire; splice in underground wire.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Protection of insulated wire; splice in underground wire. 234.241 Section 234.241 Transportation Other Regulations Relating to Transportation... of insulated wire; splice in underground wire. Insulated wire shall be protected from mechanical...
Wire-bonder-assisted integration of non-bondable SMA wires into MEMS substrates
NASA Astrophysics Data System (ADS)
Fischer, A. C.; Gradin, H.; Schröder, S.; Braun, S.; Stemme, G.; van der Wijngaart, W.; Niklaus, F.
2012-05-01
This paper reports on a novel technique for the integration of NiTi shape memory alloy wires and other non-bondable wire materials into silicon-based microelectromechanical system structures using a standard wire-bonding tool. The efficient placement and alignment functions of the wire-bonding tool are used to mechanically attach the wire to deep-etched silicon anchoring and clamping structures. This approach enables a reliable and accurate integration of wire materials that cannot be wire bonded by traditional means.
Depressive symptoms in adolescence: the association with multiple health risk behaviors.
Katon, Wayne; Richardson, Laura; Russo, Joan; McCarty, Carolyn A; Rockhill, Carol; McCauley, Elizabeth; Richards, Julie; Grossman, David C
2010-01-01
Although multiple studies of adolescents have examined the association of depression with individual health risk behaviors such as obesity or smoking, this is one of the few studies that examined the association between depression and multiple risk behaviors. A brief mail questionnaire, which screened for age, gender, weight, height, sedentary behaviors, physical activity, perception of general health, functional impairment and depressive symptoms, was completed by a sample of 2291 youth (60.7% response rate) aged 13-17 enrolled in a health care plan. A subset of youth who screened positive on the two-item depression screen and a random sample of those screening negative were approached to participate in a telephone interview with more in-depth information obtained on smoking and at-risk behaviors associated with drug and alcohol use. Youth screening positive for high levels of depressive symptoms compared to those with few or no depressive symptoms were significantly more likely to meet criteria for obesity, had a poorer perception of health, spent more time on the computer, got along less well with parents and friends, had more problems completing school work and were more likely to have experimented with smoking and a wide array of behaviors associated with drug and alcohol use. Because many adverse health behaviors that develop in adolescence continue into adulthood, the association of depressive symptoms with multiple risk behaviors and poor functioning suggest that early interventions are needed at an individual, school, community and primary care level. Copyright 2010 Elsevier Inc. All rights reserved.
Questionnaires that screen for multiple sleep disorders.
Klingman, Karen J; Jungquist, Carla R; Perlis, Michael L
2017-04-01
The goal of this review was to identify, describe, and evaluate the existing multiple sleep disorders screening questionnaires for their comprehensiveness, brevity, and psychometric quality. A systematic review was conducted using Medline/PubMed, cumulative index to nursing & allied health literature, health and psychosocial instruments and the "grey literature". Search terms were "sleep disorders, screening, questionnaires, and psychometrics". The scope of the search was limited to English language articles for adult age groups from 1989 through 2015. Of the n = 2812 articles identified, most were assessment or treatment guideline reviews, topical reviews, and/or empirical articles. Seven of the articles described multiple sleep disorders screening instruments. Of the identified instruments, two questionnaires (the Holland sleep Disorders questionnaire and sleep-50) were evaluated as comprehensive and one questionnaire (the global sleep assessment questionnaire [GSAQ]) was judged to be both comprehensive and efficient. The GSAQ was found to cover four of the six core intrinsic disorders, sleep insufficiency, and daytime sequela with 11 questions. Accordingly, the GSAQ is the most suitable for application as a general sleep disorders screener. Additional work is required to validate this instrument in the context of primary care. Finally, the future development of multiple sleep disorders screening questionnaires should not only cover all six intrinsic sleep disorders but also acquire some basic demographic information (age, sex, body mass index, presence/absence of bed partner, work status and shift) and some limited data regarding sleep sufficiency and the daytime consequences of sleep disturbance. Copyright © 2016 Elsevier Ltd. All rights reserved.
30 CFR 75.517 - Power wires and cables; insulation and protection.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Power wires and cables; insulation and...-General § 75.517 Power wires and cables; insulation and protection. [Statutory Provisions] Power wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately...
30 CFR 75.517 - Power wires and cables; insulation and protection.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Power wires and cables; insulation and...-General § 75.517 Power wires and cables; insulation and protection. [Statutory Provisions] Power wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately...
30 CFR 75.517 - Power wires and cables; insulation and protection.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Power wires and cables; insulation and...-General § 75.517 Power wires and cables; insulation and protection. [Statutory Provisions] Power wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately...
30 CFR 75.517 - Power wires and cables; insulation and protection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Power wires and cables; insulation and...-General § 75.517 Power wires and cables; insulation and protection. [Statutory Provisions] Power wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-26
... DEPARTMENT OF COMMERCE International Trade Administration [C-570-976] Galvanized Steel Wire From... exporters of galvanized steel wire (galvanized wire) from the People's Republic of China (the PRC). For... investigation are Davis Wire Corporation, Johnstown Wire Technologies, Inc., Mid- South Wire Company, Inc...
30 CFR 75.517 - Power wires and cables; insulation and protection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Power wires and cables; insulation and...-General § 75.517 Power wires and cables; insulation and protection. [Statutory Provisions] Power wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately...
Interconnect mechanisms in microelectronic packaging
NASA Astrophysics Data System (ADS)
Roma, Maria Penafrancia C.
Global economic, environmental and market developments caused major impact in the microelectronics industry. Astronomical rise of gold metal prices over the last decade shifted the use of copper and silver alloys as bonding wires. Environmental legislation on the restriction of the use of Pb launched worldwide search for lead-free solders and platings. Finally, electrical and digital uses demanded smaller, faster and cheaper devices. Ultra-fine pitch bonding, decreasing bond wire sizes and hard to bond substrates have put the once-robust stitch bond in the center of reliability issues due to stitch bond lift or open wires .Unlike the ball bond, stitch bonding does not lead to intermetallic compound formation but adhesion is dependent on mechanical deformation, interdiffusion, solid solution formation, void formation and mechanical interlocking depending on the wire material, bond configuration, substrate type , thickness and surface condition. Using Au standoff stitch bonds on NiPdAu plated substrates eliminated stitch bond lift even when the Au and Pd layers are reduced. Using the Matano-Boltzmann analysis on a STEM (Scanning Transmission Analysis) concentration profile the interdiffusion coefficient is measured to be 10-16 cm 2/s. Wire pull strength data showed that the wire pull strength is 0.062N and increases upon stress testing. Meanwhile, coating the Cu wire with Pd, not only increases oxidation resistance but also improved adhesion due to the formation of a unique interfacial adhesion layers. Adhesion strength as measured by pull showed the Cu wire bonded to Ag plated Cu substrate (0.132N) to be stronger than the Au wire bonded on the same substrate (0.124N). Ag stitch bonded to Au is predicted to be strong but surface modification made the adhesion stronger. However, on the Ag ball bonded to Al showed multiple IMC formation with unique morphology exposed by ion milling and backscattered scanning electron microscopy. Adding alloying elements in the Ag wire alloy showed differences in adhesion strength and IMC formation. Bond strength by wire pull testing showed the 95Ag alloy with higher values while shear bond testing showed the 88Ag higher bond strength. Use of Cu pillars in flip chips and eutectic bonding in wafer level chip scale packages are direct consequences of diminishing interconnect dimension as a result of the drive for miniaturization. The combination of Cu-Sn interdiffusion, Kirkendall mechanism and heterogeneous vacancy precipitation are the main causes of IMC and void formation in Cu pillar - Sn solder - Cu lead frame sandwich structure. However, adding a Ni barrier agent showed less porous IMC layer as well as void formation as a result of the modified Cu and Sn movement well as the void formation. Direct die to die bonding using Al-Ge eutectic bonds is necessary when 3D integration is needed to reduce the footprint of a package. Hermeticity and adhesion strength are a function of the Al/Ge thickness ratio, bonding pressure, temperature and time. Scanning Electron Microscope (SEM) and Focused Ion Beam (FIB) allowed imaging of interfacial microstructures, porosity, grain morphology while Scanning Transmission Electron microscope (STEM) provided diffusion profile and confirmed interdiffusion. Ion polishing technique provided information on porosity and when imaged using backscattered mode, grain structure confirmed mechanical deformation of the bonds. Measurements of the interfacial bond strength are made by wire pull tests and ball shear tests based on existing industry standard tests. However, for the Al-Ge eutectic bonds, no standard strength is available so a test is developed using the stud pull test method using the Dage 4000 Plus to yield consistent results. Adhesion strengths of 30-40 MPa are found for eutectic bonded packages however, as low as 20MPa was measured in low temperature bonded areas.
Orbiter Kapton wire operational requirements and experience
NASA Technical Reports Server (NTRS)
Peterson, R. V.
1994-01-01
The agenda of this presentation includes the Orbiter wire selection requirements, the Orbiter wire usage, fabrication and test requirements, typical wiring installations, Kapton wire experience, NASA Kapton wire testing, summary, and backup data.
30 CFR 75.701-4 - Grounding wires; capacity of wires.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity of wires. 75.701-4... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.701-4 Grounding wires; capacity of wires. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames...
30 CFR 75.701-4 - Grounding wires; capacity of wires.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Grounding wires; capacity of wires. 75.701-4... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.701-4 Grounding wires; capacity of wires. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Improved Plow Steel, Independent Wire Rope Core, Wire Rope and Wire Rope Slings [In tons of 2,000 pounds... for Improved Plow Steel, Independent Wire Rope Core, Wire Rope Slings [in tons of 2,000 pounds] Two...-4—Rated Capacities for Improved Plow Steel, Fiber Core, Wire Rope and Wire Rope Slings [in tons of 2...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Improved Plow Steel, Independent Wire Rope Core, Wire Rope and Wire Rope Slings [In tons of 2,000 pounds... for Improved Plow Steel, Independent Wire Rope Core, Wire Rope Slings [in tons of 2,000 pounds] Two...-4—Rated Capacities for Improved Plow Steel, Fiber Core, Wire Rope and Wire Rope Slings [in tons of 2...
Characterization of copper and nichrome wires for safety fuse
NASA Astrophysics Data System (ADS)
Murdani, E.
2016-11-01
Fuse is an important component of an electrical circuit to limiting the current through the electrical circuit for electrical equipment safety. Safety fuses are made of a conductor such as copper and nichrome wires. The aim of this research was to determine the maximum current that can flow in the conductor wires (copper and nichrome). In the experiment used copper and nichrome wires by varying the length of wires (0.2 cm to 20 cm) and diameter of wires (0.1, 0.2, 0.3, 0.4 and 0.5) mm until maximum current reached that marked by melted or broken wire. From this experiment, it will be obtained the dependences data of maximum current to the length and diameter of wires. All data are plotted and it's known as a standard curve. The standard curve will provide an alternative choice of replacing fuse wire according to the maximum current requirement, including the wire type (copper and nichrome wires) and wire dimensions (length and diameter of wire).
Length-dependent structural stability of linear monatomic Cu wires
NASA Astrophysics Data System (ADS)
Singh, Gurvinder; Kumar, Krishan; Singh, Baljinder; Moudgil, R. K.
2018-05-01
We present first-principle calculations based on density functional theory for the finite-length monatomic Cu atom linear wires. The structure and its stability with increasing wire length in terms of number of atoms (N) is determined. Interestingly, the bond length is found to exhibit an oscillatory structure (the so-called magic length phenomenon), with a qualitative change in oscillatory behavior as one moves from even N wire to odd N wire. The even N wires follow simple even-odd oscillations whereas odd N wires show a phase change at the half length of the wires. The stability of the wire structure, determined in terms of the wire formation energy, also contains even-odd oscillation as a function of wire length. However, the oscillations in formation energy reverse its phase after the wire length is increased beyond N=12. Our findings are seen to be qualitatively consistent with recent simulations for a similar class finite-length metal atom wires.
Multiplex and label-free screening of foodborne pathogens using surface plasmon resonance imaging
USDA-ARS?s Scientific Manuscript database
In order to protect outbreaks caused by foodborne pathogens, more rapid and efficient methods are needed for pathogen screening from food samples. Surface plasmon resonance imaging (SPRi) is an emerging optical technique, which allows for label-free screening of multiple targets simultaneously with ...
Conceptual understanding of screen media parenting: Report of a working group
USDA-ARS?s Scientific Manuscript database
Screen media (television, computers, and videogames) use has been linked to multiple child outcomes, including obesity. Parents can be an important influence on children's screen use. There has been an increase in the number of instruments available to assess parenting in feeding and physical activi...
Screen Layout Design: Research into the Overall Appearance of the Screen.
ERIC Educational Resources Information Center
Grabinger, R. Scott
1989-01-01
Examines the current state of research into the visual effects of screen designs used in computer-assisted instruction and suggests areas for future efforts. Topics discussed include technical elements and comprehensibility elements in layout design; single element and multiple element research methodologies; dependent variables; and learning…
High-throughput screening (HTS) for potential thyroid–disrupting chemicals requires a system of assays to capture multiple molecular-initiating events (MIEs) that converge on perturbed thyroid hormone (TH) homeostasis. Screening for MIEs specific to TH-disrupting pathways is limi...
Responsible implementation of expanded carrier screening
Henneman, Lidewij; Borry, Pascal; Chokoshvili, Davit; Cornel, Martina C; van El, Carla G; Forzano, Francesca; Hall, Alison; Howard, Heidi C; Janssens, Sandra; Kayserili, Hülya; Lakeman, Phillis; Lucassen, Anneke; Metcalfe, Sylvia A; Vidmar, Lovro; de Wert, Guido; Dondorp, Wybo J; Peterlin, Borut
2016-01-01
This document of the European Society of Human Genetics contains recommendations regarding responsible implementation of expanded carrier screening. Carrier screening is defined here as the detection of carrier status of recessive diseases in couples or persons who do not have an a priori increased risk of being a carrier based on their or their partners' personal or family history. Expanded carrier screening offers carrier screening for multiple autosomal and X-linked recessive disorders, facilitated by new genetic testing technologies, and allows testing of individuals regardless of ancestry or geographic origin. Carrier screening aims to identify couples who have an increased risk of having an affected child in order to facilitate informed reproductive decision making. In previous decades, carrier screening was typically performed for one or few relatively common recessive disorders associated with significant morbidity, reduced life-expectancy and often because of a considerable higher carrier frequency in a specific population for certain diseases. New genetic testing technologies enable the expansion of screening to multiple conditions, genes or sequence variants. Expanded carrier screening panels that have been introduced to date have been advertised and offered to health care professionals and the public on a commercial basis. This document discusses the challenges that expanded carrier screening might pose in the context of the lessons learnt from decades of population-based carrier screening and in the context of existing screening criteria. It aims to contribute to the public and professional discussion and to arrive at better clinical and laboratory practice guidelines. PMID:26980105
DiMarco, Anthony F
2018-06-01
Diaphragm pacing (DP) is a useful and cost-effective alternative to mechanical ventilation in patients with ventilator-dependent spinal cord injury and central hypoventilation syndrome. Patients with SCI should be carefully screened to assess the integrity of their phrenic nerves. In eligible patients, DP improves mobility, speech, olfaction, and quality of life. The stigma of being attached to a mechanical device and risk of ventilator disconnection are eliminated. There is also some evidence that DP results in a reduction in the rate of respiratory tract infections. DP is associated with infrequent side effects and complications, such as wire breakage, radiofrequency failure, and infection. Copyright © 2018 Elsevier Inc. All rights reserved.
The effect of free-stream turbulence on heat transfer from a flat plate
NASA Technical Reports Server (NTRS)
Sugawara, Sugao; Sato, Takashi; Komatsu, Hiroyasu; Osaka, Hiroichi
1958-01-01
Turbulence was generated by using screens, and the turbulence percentage was measured by a hot-wire anemometer both in the boundary layer and the free stream. The local heat-transfer coefficient was measured at 12 locations along the plate for the cases of various turbulence levels. The transition Reynolds number from laminar to turbulent flow decreases as the main-stream turbulence level increases. In the range of laminar heat transfer the effect of turbulence in the main flow was not great, but in the range of turbulent heat transfer the heat-transfer coefficient increases according to the increase of turbulence.
Jongsma, Marije A; Pelser, Floris D H; van der Mei, Henny C; Atema-Smit, Jelly; van de Belt-Gritter, Betsy; Busscher, Henk J; Ren, Yijin
2013-05-01
Bonded retainers are used in orthodontics to maintain treatment result. Retention wires are prone to biofilm formation and cause gingival recession, bleeding on probing and increased pocket depths near bonded retainers. In this study, we compare in vitro and in vivo biofilm formation on different wires used for bonded retainers and the susceptibility of in vitro biofilms to oral antimicrobials. Orthodontic wires were exposed to saliva, and in vitro biofilm formation was evaluated using plate counting and live/dead staining, together with effects of exposure to toothpaste slurry alone or followed by antimicrobial mouthrinse application. Wires were also placed intra-orally for 72 h in human volunteers and undisturbed biofilm formation was compared by plate counting and live/dead staining, as well as by denaturing gradient gel electrophoresis for compositional differences in biofilms. Single-strand wires attracted only slightly less biofilm in vitro than multi-strand wires. Biofilms on stainless steel single-strand wires however, were much more susceptible to antimicrobials from toothpaste slurries and mouthrinses than on single-strand gold wires and biofilms on multi-strand wires. Also, in vivo significantly less biofilm was found on single-strand than on multi-strand wires. Microbial composition of biofilms was more dependent on the volunteer involved than on wire type. Biofilms on single-strand stainless steel wires attract less biofilm in vitro and are more susceptible to antimicrobials than on multi-strand wires. Also in vivo, single-strand wires attract less biofilm than multi-strand ones. Use of single-strand wires is preferred over multi-strand wires, not because they attract less biofilm, but because biofilms on single-strand wires are not protected against antimicrobials as in crevices and niches as on multi-strand wires.
Accelerated life test of sputtering and anode deposit spalling in a small mercury ion thruster
NASA Technical Reports Server (NTRS)
Power, J. L.
1975-01-01
Tantalum and molybdenum sputtered from discharge chamber components during operation of a 5 centimeter diameter mercury ion thruster adhered much more strongly to coarsely grit blasted anode surfaces than to standard surfaces. Spalling of the sputtered coating did occur from a coarse screen anode surface but only in flakes less than a mesh unit long. The results were obtained in a 200 hour accelerated life test conducted at an elevated discharge potential of 64.6 volts. The test approximately reproduced the major sputter erosion and deposition effects that occur under normal operation but at approximately 75 times the normal rate. No discharge chamber component suffered sufficient erosion in the test to threaten its structural integrity or further serviceability. The test indicated that the use of tantalum-surfaced discharge chamber components in conjunction with a fine wire screen anode surface should cure the problems of sputter erosion and sputtered deposits spalling in long term operation of small mercury ion thrusters.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Wire. 111.60-11 Section 111.60-11 Shipping COAST GUARD... Wiring Materials and Methods § 111.60-11 Wire. (a) Wire must be in an enclosure. (b) Wire must be component insulated. (c) Wire, other than in switchboards, must meet the requirements in sections 24.6.7 and...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Wire. 111.60-11 Section 111.60-11 Shipping COAST GUARD... Wiring Materials and Methods § 111.60-11 Wire. (a) Wire must be in an enclosure. (b) Wire must be component insulated. (c) Wire, other than in switchboards, must meet the requirements in sections 24.6.7 and...
Conceptual Design of an Electric Sail Technology Demonstration Mission Spacecraft
NASA Technical Reports Server (NTRS)
Wiegmann, Bruce M.
2017-01-01
There is great interest in examining the outer planets of our solar system and Heliopause region (edge of Solar System) and beyond regions of interstellar space by both the Planetary and Heliophysics communities. These needs are well docu-mented in the recent National Academy of Sciences Decadal Surveys. There is significant interest in developing revolutionary propulsion techniques that will enable such Heliopause scientific missions to be completed within 10 to15 years of the launch date. One such enabling propulsion technique commonly known as Electric Sail (E-Sail) propulsion employs positively charged bare wire tethers that extend radially outward from a rotating spacecraft spinning at a rate of one revolution per hour. Around the positively charged bare-wire tethers, a Debye Sheath is created once positive voltage is applied. This sheath stands off of the bare wire tether at a sheath diameter that is proportional to the voltage in the wire coupled with the flux density of solar wind ions within the solar system (or the location of spacecraft in the solar system. The protons that are expended from the sun (solar wind) at 400 to 800 km/sec are electrostatically repelled away from these positively charged Debye sheaths and propulsive thrust is produced via the resulting momentum transfer. The amount of thrust produced is directly proportional to the total wire length. The Marshall Space Flight Center (MSFC) Electric Sail team is currently funded via a two year Phase II NASA Innovative Advanced Concepts (NIAC) awarded in July 2015. The team's current activities are: 1) Developing a Particle in Cell (PIC) numeric engineering model from the experimental data collected at MSFC's Solar Wind Facility on the interaction between simulated solar wind interaction with a charged bare wire that can be applied to a variety of missions, 2) The development of the necessary tether deployers and tethers to enable successful de-ployment of multiple, multi km length bare tethers, 3) Controllability of the space-craft via a voltage bias to steer itself through the solar system to destinations of discovery. These activities once demonstrated analytically, will require a technology demonstration mission (TDM) around the year2020 to demonstrate that all systems work together seamlessly before a Heliophysics Electrostatic Rapid Transit System (HERTS) mission could be initiated. A notional TDM spacecraft that meets the requirements of such a mission will be showcased in this paper.
Wosar, Marc A; Marcellin-Little, Denis J; Roe, Simon C
2002-01-01
To evaluate the effects of bolt torque, wire size, and component reuse on the ability to maintain wire tension in 3 external skeletal fixation systems. Biomechanical study. Yield strength in tension of 1.0-, 1.2-, 1.5-, and 1.6-mm-diameter wires, and yield strength in torque of Hofmann Small Bone Fixation (SBF) cannulated and slotted bolts and IMEX regular and miniature bolts were determined on a testing machine. The minimum bolt tightening torque needed to prevent wire slippage at clinically recommended wire tensions was determined. Components were tested 10 times, and loads at slippage were recorded. The IMEX system required a mean of 8 Nm of bolt tightening torque to maintain 900 N (1.6-mm wires). The SBF system required a mean of 3 Nm bolt torque to maintain 300 N (1.0-mm wires) and 5 Nm to maintain 600 N (1.2-mm wires). The SBF cannulated bolt required 9 Nm of torque to maintain 900 N (1.5-mm wires). The SBF slotted bolts could only maintain 800 N before yield. The IMEX miniature system required a mean bolt torque of 1.1 Nm to maintain 300 N. The cannulated and slotted bolts from both manufacturers failed to maintain 70% of initial wire tension after 7 and 4 uses, respectively. The IMEX systems and the SBF system using 1.0- and 1.2-mm wires could maintain clinically recommended wire tension safely. Only the IMEX system could maintain clinically recommended wire tension safely using 1.5- or 1.6-mm wires. The SBF system using 1.0- and 1.2-mm wires and the IMEX system using all wire sizes can maintain clinically relevant wire tension. The SBF system using 1.5-mm wires could not. Cannulated and slotted bolts should not be used more than 6 and 3 times, respectively. Nuts should not be reused. Copyright 2002 by The American College of Veterinary Surgeons
A developmental screening tool for toddlers with multiple domains based on Rasch analysis.
Hwang, Ai-Wen; Chou, Yeh-Tai; Hsieh, Ching-Lin; Hsieh, Wu-Shiun; Liao, Hua-Fang; Wong, Alice May-Kuen
2015-01-01
Using multidomain developmental screening tools is a feasible method for pediatric health care professionals to identify children at risk of developmental problems in multiple domains simultaneously. The purpose of this study was to develop a Rasch-based tool for Multidimensional Screening in Child Development (MuSiC) for children aged 0-3 years. The MuSic was developed by constructing items bank based on three commonly used screening tools, validating with developmental status (at risk for delay or not) on five developmental domains. Parents of a convenient sample of 632 children (aged 3-35.5 months) with and without developmental delays responded to items from the three screening tools funded by health authorities in Taiwan. Item bank was determined by item fit of Rasch analysis for each of the five developmental domains (cognitive skills, language skills, gross motor skills, fine motor skills, and socioadaptive skills). Children's performance scores in logits derived in Rasch analysis were validated with developmental status for each domain using the area under receiver operating characteristic curves. MuSiC, a 75-item developmental screening tool for five domains, was derived. The diagnostic validity of all five domains was acceptable for all stages of development, except for the infant stage (≤11 months and 15 days). MuSiC can be applied simultaneously to well-child care visits as a universal screening tool for children aged 1-3 years on multiple domains. Items with sound validity for infants need to be further developed. Copyright © 2014. Published by Elsevier B.V.
49 CFR 236.71 - Signal wires on pole line and aerial cable.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Signal wires on pole line and aerial cable. 236.71... Instructions: All Systems Wires and Cables § 236.71 Signal wires on pole line and aerial cable. Signal wire on... pole or other support. Signal wire shall not interfere with, or be interfered by, other wires on the...
49 CFR 236.71 - Signal wires on pole line and aerial cable.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Signal wires on pole line and aerial cable. 236.71... Instructions: All Systems Wires and Cables § 236.71 Signal wires on pole line and aerial cable. Signal wire on... pole or other support. Signal wire shall not interfere with, or be interfered by, other wires on the...
Atom chips in the real world: the effects of wire corrugation
NASA Astrophysics Data System (ADS)
Schumm, T.; Estève, J.; Figl, C.; Trebbia, J.-B.; Aussibal, C.; Nguyen, H.; Mailly, D.; Bouchoule, I.; Westbrook, C. I.; Aspect, A.
2005-02-01
We present a detailed model describing the effects of wire corrugation on the trapping potential experienced by a cloud of atoms above a current carrying micro wire. We calculate the distortion of the current distribution due to corrugation and then derive the corresponding roughness in the magnetic field above the wire. Scaling laws are derived for the roughness as a function of height above a ribbon shaped wire. We also present experimental data on micro wire traps using cold atoms which complement some previously published measurements [CITE] and which demonstrate that wire corrugation can satisfactorily explain our observations of atom cloud fragmentation above electroplated gold wires. Finally, we present measurements of the corrugation of new wires fabricated by electron beam lithography and evaporation of gold. These wires appear to be substantially smoother than electroplated wires.
Acquisition of Turbulence Data Using the DST Group Constant-Temperature Hot-Wire Anemometer System
2015-10-01
fluctuations in the low-speed wind tunnel at DST Group. The use of both single- wire and crossed- wire (2 wire ) probes is described. Areas covered include a...fluid-flow studies, including testing of models of aircraft, ships and submarines in wind and water tunnels. Hot- wire anemometers and associated hot...spectra of velocity fluctuations in the low-speed wind tunnel at DST Group. The use of both single- wire and crossed- wire (2 wires ) probes is
Integrating the Gradient of the Thin Wire Kernel
NASA Technical Reports Server (NTRS)
Champagne, Nathan J.; Wilton, Donald R.
2008-01-01
A formulation for integrating the gradient of the thin wire kernel is presented. This approach employs a new expression for the gradient of the thin wire kernel derived from a recent technique for numerically evaluating the exact thin wire kernel. This approach should provide essentially arbitrary accuracy and may be used with higher-order elements and basis functions using the procedure described in [4].When the source and observation points are close, the potential integrals over wire segments involving the wire kernel are split into parts to handle the singular behavior of the integrand [1]. The singularity characteristics of the gradient of the wire kernel are different than those of the wire kernel, and the axial and radial components have different singularities. The characteristics of the gradient of the wire kernel are discussed in [2]. To evaluate the near electric and magnetic fields of a wire, the integration of the gradient of the wire kernel needs to be calculated over the source wire. Since the vector bases for current have constant direction on linear wire segments, these integrals reduce to integrals of the form
An Obstacle Alerting System for Agricultural Application
NASA Technical Reports Server (NTRS)
DeMaio, Joe
2003-01-01
Wire strikes are a significant cause of helicopter accidents. The aircraft most at risk are aerial applicators. The present study examines the effectiveness of a wire alert delivered by way of the lightbar, a GPS-based guidance system for aerial application. The alert lead-time needed to avoid an invisible wire is compared with that to avoid a visible wire. A flight simulator was configured to simulate an agricultural application helicopter. Two pilots flew simulated spray runs in fields with visible wires, invisible wires, and no wires. The wire alert was effective in reducing wire strikes. A lead-time of 3.5 sec was required for the alert to be effective. The lead- time required was the same whether the pilot could see the wire or not.
NASA Astrophysics Data System (ADS)
Sundaram, Rajyashree; Yamada, Takeo; Hata, Kenji; Sekiguchi, Atsuko
2018-04-01
We present the influence of density, structural regularity, and purity of carbon nanotube wires (CNTWs) used as Cu electrodeposition templates on fabricating homogeneous high-electrical performance CNT-Cu wires lighter than Cu. We show that low-density CNTWs (<0.6 g/cm3 for multiwall nanotube wires) with regular macro- and microstructures and high CNT content (>90 wt %) are essential for making homogeneous CNT-Cu wires. These homogeneous CNT-Cu wires show a continuous Cu matrix with evenly mixed nanotubes of high volume fractions (˜45 vol %) throughout the wire-length. Consequently, the composite wires show densities ˜5.1 g/cm3 (33% lower than Cu) and electrical conductivities ˜6.1 × 104 S/cm (>100 × CNTW conductivity). However, composite wires from templates with higher densities or structural inconsistencies are non-uniform with discontinuous Cu matrices and poor CNT/Cu mixing. These non-uniform CNT-Cu wires show conductivities 2-6 times lower than the homogeneous composite wires.
Adherence to multiple cancer screening tests among women living in Appalachia Ohio
Katz, Mira L.; Reiter, Paul L.; Young, Gregory S.; Pennell, Michael L.; Tatum, Cathy M.; Paskett, Electra D.
2015-01-01
Background There is a lack of information about the correlates of completing all three cancer screening tests among women living in Appalachia. Methods Cross-sectional telephone interviews were conducted (April-September 2013) among women (n=637) ages 51-75 from 12 Appalachia Ohio counties. Outcomes of within screening guidelines were verified by medical record. Multivariable logistic regression models identified correlates of being within guidelines for all three cancer screening tests. Results Screening rates were: mammography (32.1%), Pap test (36.1%), and a colorectal cancer test (30.1%). Only 8.6% of women were within guidelines for all tests. Having had a check-up in the past two years and having received a screening recommendation were significantly related to being within guidelines for all three tests (p<0.01). Participants with higher annual household incomes ($60,000+; OR=3.53, 95% CI: 1.49, 8.33) and conditions requiring regular medical visits (OR=3.16, 95% CI: 1.29, 7.74) were more likely to be within guidelines for all three screening tests. Conclusion Less than 10% of women had completed screening within guidelines for all three screening tests. Regular contact with the healthcare system and higher incomes were significant predictors of being within guidelines. Impact Within guidelines rates for the three recommended cancer screening tests is low among women in Appalachia Ohio. This finding illustrates the need for innovative interventions to improve rates of multiple cancer screening tests. PMID:26282630
Schneidereit, Dominik; Kraus, Larissa; Meier, Jochen C; Friedrich, Oliver; Gilbert, Daniel F
2017-06-15
High-content screening microscopy relies on automation infrastructure that is typically proprietary, non-customizable, costly and requires a high level of skill to use and maintain. The increasing availability of rapid prototyping technology makes it possible to quickly engineer alternatives to conventional automation infrastructure that are low-cost and user-friendly. Here, we describe a 3D printed inexpensive open source and scalable motorized positioning stage for automated high-content screening microscopy and provide detailed step-by-step instructions to re-building the device, including a comprehensive parts list, 3D design files in STEP (Standard for the Exchange of Product model data) and STL (Standard Tessellation Language) format, electronic circuits and wiring diagrams as well as software code. System assembly including 3D printing requires approx. 30h. The fully assembled device is light-weight (1.1kg), small (33×20×8cm) and extremely low-cost (approx. EUR 250). We describe positioning characteristics of the stage, including spatial resolution, accuracy and repeatability, compare imaging data generated with our device to data obtained using a commercially available microplate reader, demonstrate its suitability to high-content microscopy in 96-well high-throughput screening format and validate its applicability to automated functional Cl - - and Ca 2+ -imaging with recombinant HEK293 cells as a model system. A time-lapse video of the stage during operation and as part of a custom assembled screening robot can be found at https://vimeo.com/158813199. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Measuring the Pain Area: An Intra- and Inter-Rater Reliability Study Using Image Analysis Software.
Dos Reis, Felipe Jose Jandre; de Barros E Silva, Veronica; de Lucena, Raphaela Nunes; Mendes Cardoso, Bruno Alexandre; Nogueira, Leandro Calazans
2016-01-01
Pain drawings have frequently been used for clinical information and research. The aim of this study was to investigate intra- and inter-rater reliability of area measurements performed on pain drawings. Our secondary objective was to verify the reliability when using computers with different screen sizes, both with and without mouse hardware. Pain drawings were completed by patients with chronic neck pain or neck-shoulder-arm pain. Four independent examiners participated in the study. Examiners A and B used the same computer with a 16-inch screen and wired mouse hardware. Examiner C used a notebook with a 16-inch screen and no mouse hardware, and Examiner D used a computer with an 11.6-inch screen and a wireless mouse. Image measurements were obtained using GIMP and NIH ImageJ computer programs. The length of all the images was measured using GIMP software to a set scale in ImageJ. Thus, each marked area was encircled and the total surface area (cm(2) ) was calculated for each pain drawing measurement. A total of 117 areas were identified and 52 pain drawings were analyzed. The intrarater reliability between all examiners was high (ICC = 0.989). The inter-rater reliability was also high. No significant differences were observed when using different screen sizes or when using or not using the mouse hardware. This suggests that the precision of these measurements is acceptable for the use of this method as a measurement tool in clinical practice and research. © 2014 World Institute of Pain.
Optical Property Enhancement and Durability Evaluation of Heat Receiver Aperture Shield Materials
NASA Technical Reports Server (NTRS)
deGroh, Kim K.; Jaworske, Donald A.; Smith, Daniela C.
1998-01-01
Under the Solar Dynamic Flight Demonstration (SDFD) program, NASA Lewis Research Center worked with AlliedSignal Aerospace, the heat receiver contractor, on the development, characterization and durability testing of refractory metals to obtain appropriate optical and thermal properties for the SDFD heat receiver aperture shield. Molybdenum and tungsten foils were grit-blasted using silicon carbide or alumina grit under various grit-blasting conditions for optical property enhancement. Black rhenium coated tungsten foil was also evaluated. Tungsten, black rhenium-coated tungsten, and grit-blasted tungsten screens of various mesh sizes were placed over the pristine and grit-blasted foils for optical property characterization. Grit-blasting was found to be effective in decreasing the specular reflectance and the absorptance/emittance ratio of the refractory foils. The placement of a screen further enhanced these optical properties, with a grit-blasted screen over a grit-blasted foil producing the best results. Based on the optical property enhancement results, samples were tested for atomic oxygen and vacuum heat treatment durability. Grit-blasted (Al2O3 grit) 2 mil tungsten foil was chosen for the exterior layer of the SDFD heat receiver aperture shield. A 0.007 in. wire diameter, 20 x 20 mesh tungsten screen was chosen to cover the tungsten foil. Based on these test results, a heat receiver aperture shield test unit has been built with the screen covered grit-blast tungsten foil exterior layers. The aperture shield was tested and verified the thermal and structural durability of the outer foil layers during an off-pointing period.
Ridley, Taylor J; Freking, Will; Erickson, Lauren O; Ward, Christina Marie
2017-07-01
To determine whether there is a difference in the incidence of infection between exposed and buried K-wires when used to treat phalangeal, metacarpal, and distal radius fractures. We conducted a retrospective review identifying all patients aged greater than 16 years who underwent fixation of phalangeal, metacarpal, or distal radius fractures with K-wires between 2007 and 2015. We recorded patient demographic data, fracture location, number of K-wires used, whether K-wires were buried or left exposed, and duration of K-wire placement. A total of 695 patients met inclusion criteria. Surgeons buried K-wires in 207 patients and left K-wires exposed in 488. Infections occurred more frequently in exposed K-wire cases than in buried K-wire ones. Subgroup analysis based on fracture location revealed a significantly increased risk of being treated for infection when exposed K-wires were used for metacarpal fractures. Patients with exposed K-wires for fixation of phalangeal, metacarpal, or distal radius fractures were more likely to be treated for a pin-site infection than those with K-wires buried beneath the skin. Metacarpal fractures treated with exposed K-wires were 2 times more likely to be treated for a pin-site infection (17.6% of exposed K wire cases vs 8.7% of buried K wire cases). Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Noise Radiation from Single and Multiple Rod Configurations
NASA Technical Reports Server (NTRS)
Hutcheson, Florence V.; Brooks, Thomas F.
2006-01-01
Acoustic measurements were performed on single and multiple rod configurations to study the effect of Reynolds number, surface roughness, freestream turbulence, proximity and wake interference on the radiated noise. The Reynolds number ranged from 3.8 x 10(exp 3) to 10(exp 5). Directivity measurements were performed to determine how well the dipole assumption for the radiation of vortex shedding noise holds for the different model configurations tested. The dependence of the peak Sound Pressure Level on velocity was also examined. Several concepts for the reduction of the noise radiating from cylindrical rods were tested. It was shown that wire wraps and collar distributions could be used to significantly reduce the noise radiating from rods in tandem configurations.
Autocalibration of a projector-camera system.
Okatani, Takayuki; Deguchi, Koichiro
2005-12-01
This paper presents a method for calibrating a projector-camera system that consists of multiple projectors (or multiple poses of a single projector), a camera, and a planar screen. We consider the problem of estimating the homography between the screen and the image plane of the camera or the screen-camera homography, in the case where there is no prior knowledge regarding the screen surface that enables the direct computation of the homography. It is assumed that the pose of each projector is unknown while its internal geometry is known. Subsequently, it is shown that the screen-camera homography can be determined from only the images projected by the projectors and then obtained by the camera, up to a transformation with four degrees of freedom. This transformation corresponds to arbitrariness in choosing a two-dimensional coordinate system on the screen surface and when this coordinate system is chosen in some manner, the screen-camera homography as well as the unknown poses of the projectors can be uniquely determined. A noniterative algorithm is presented, which computes the homography from three or more images. Several experimental results on synthetic as well as real images are shown to demonstrate the effectiveness of the method.
NASA Astrophysics Data System (ADS)
Ciofu, C.; Stan, G.
2016-11-01
Elephant's trunk robotic arms driven by wires and pulley mechanisms have issues with wires stiffness because of the entailed elastic deformations that is causing errors of positioning. Static and dynamic loads from each joint of the robotic arm affect the stiffness of driving wires and precision positioning. The influence of wires elastic deformation on precision positioning decreases with the increasing of wires stiffness by using different pre-tensioning devices. In this paper, we analyze the variation of driving wires stiffness particularly to each wire driven joint. We obtain optimum wires stiffness variation by using an analytical method that highlights the efficiency of pre-tensioning mechanism. The analysis of driving wires stiffness is necessary for taking appropriate optimization measures of robotic arm dynamic behavior and, thus, for decreasing positioning errors of the elephant's trunk robotic arm with inner actuation through wires/cables.
Hydrogen in Mono-Atomic Gold Wires
NASA Astrophysics Data System (ADS)
Barnett, Robert N.; Sherbakov, Andrew G.; Landman, Uzi; Hakkinen, Hannu
2004-03-01
Results of ab-initio scalar relativistic density functional calculations of the interaction between a mono-atomic gold wire (suspended between two gold tips) and a hydrogen molecule, at various stages of wire stretching, are presented. The hydrogen molecule does not bind to the wire until the wire is sufficiently stretched, i.e. starting to break, at which time the molecule inserts itself into the wire restoring a fraction of the conductance quantum g. With subsequent compression of the wire the axis of the molecule gradually tips away from the wire axis until it becomes "quasi-dissociated" with the H-H axis perpendicular to the wire. At this point the conductance almost vanishes, while for the bare wire the conductance at this tip-to-tip separation is close to 1g. These results, and the frequency of various vibrational modes of the hydrogen molecule, are compared with recent experimental and theoretical work involving platinum wires.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.
2013-05-01
In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, themore » gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.« less
47 CFR 76.802 - Disposition of cable home wiring.
Code of Federal Regulations, 2010 CFR
2010-10-01
... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.802 Disposition of cable home wiring... alternative video programming service provider connects its wiring to the home wiring before the incumbent... alternative video programming service provider shall be responsible for ensuring that the incumbent's wiring...
DESIGN: a program to create data entry programs
J. Michael Wuerth; David R. Weise
1994-01-01
Scientific data entry can be an exacting process. The specific information needs change from investigation to investigation. A computer program to design custom data screens is described. The program, DESIGN, generates the necessary C programming language source code to create a basic data entry program. Data entry screens can contain multiple nested screens. Users can...
Mishra, Girish; Sharma, Yojana; Mehta, Kanishk; Patel, Gunjan
2013-04-01
Deafness is commonest curable childhood handicap. Most remedies and programmes don't address this issue at childhood level leading to detrimental impact on development of newborns. Aims and objectives are (A) screen all newborns for deafness and detect prevalence of deafness in children less than 2 years of age. and (B) assess efficacy of multi-staged OAE/ABR protocol for hearing screening. Non-randomized, prospective study from August 2008 to August 2011. All infants underwent a series of oto-acoustic emission (OAE) and final confirmatory auditory brainstem evoked response (ABR) audiometry. Finally, out of 1,101 children, 1,069 children passed the test while 12 children had impaired hearing after final testing, confirmed by ABR. Positive predictive value of OAE after multiple test increased to 100 %. OAE-ABR test series is effective in screening neonates and multiple tests reduce economic burden. High risk screening will miss nearly 50 % deaf children, thus universal screening is indispensable in picking early deafness.
Comparison of three different orthodontic wires for bonded lingual retainer fabrication
Uysal, Tancan; Gul, Nisa; Alan, Melike Busra; Ramoglu, Sabri Ilhan
2012-01-01
Objective We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication. Methods We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), 0.016 × 0.022-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III). To test detachment force, deformation, and fracture mode, we embedded 94 lower incisor teeth in acrylic blocks in pairs. Retainer wires were bonded to the teeth and vertically directed force was applied to the wire. To test pull-out force, wires were embedded in composite that was placed in a hole at the center of an acrylic block. Tensile force was applied along the long axis of the wire. Results Detachment force and mode of fracture were not different between groups. Deformation was significantly higher in groups II and III than in group I (p < 0.001). Mean pull-out force was significantly higher for group I compared to groups II and III (p < 0.001). Conclusions Detachment force and fracture mode were similar for all wires, but greater deformations were seen in dead-soft wires. Wire pull-out force was significantly higher for five-stranded coaxial wire than for the other wires tested. Five-stranded coaxial wires are suggested for use in bonded lingual retainers. PMID:23112930
Electronic screen use and selected somatic symptoms in 10-12 year old children.
Taehtinen, Richard E; Sigfusdottir, Inga Dora; Helgason, Asgeir R; Kristjansson, Alfgeir L
2014-10-01
Screen-based media use by children and adolescents has increased in recent years but the consequences of their use are not well understood. The objective of this study was to provide a comprehensive examination of the relationship between screen-based activities and a selection of single and multiple self-reported somatic symptoms in a large sample of 10-12 year old children. We use data from the population-based 2011 Youth in Iceland school survey (N=10,829, response rate: 84.5%, boys: 49.9%) that is conducted triennially in 5th-7th grades in all secondary schools in Iceland. Self-reported measures of common screen-based activities were hypothesized to predict the odds of dizziness, tremors, headaches, stomach aches, and multiple symptoms. In general the reported prevalence of symptoms increased with greater number of hours reported on screen based activity for boys and girls. This held for all individual screen activities as well as the cumulative measure of daily minutes spent on screen-based media and prevalence of one or more somatic symptoms. This study confirms previous findings and puts forth additional information concerning the relationship between the prevalence of electronic screen use and somatic symptoms in 10-12 year old children. Copyright © 2014 Elsevier Inc. All rights reserved.
30 CFR 77.1430 - Wire ropes; scope.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Wire ropes; scope. 77.1430 Section 77.1430... Hoisting Wire Ropes § 77.1430 Wire ropes; scope. (a) Sections 77.1431 through 77.1438 apply to wire ropes.... (b) These standards do not apply to wire ropes used for elevators. ...
49 CFR 234.231 - Fouling wires.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Fouling wires. 234.231 Section 234.231..., Inspection, and Testing Maintenance Standards § 234.231 Fouling wires. Each set of fouling wires in a highway... single duplex wire with single plug acting as fouling wires is prohibited. Existing installations having...
30 CFR 77.1430 - Wire ropes; scope.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Wire ropes; scope. 77.1430 Section 77.1430... Hoisting Wire Ropes § 77.1430 Wire ropes; scope. (a) Sections 77.1431 through 77.1438 apply to wire ropes.... (b) These standards do not apply to wire ropes used for elevators. ...
49 CFR 234.231 - Fouling wires.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Fouling wires. 234.231 Section 234.231..., Inspection, and Testing Maintenance Standards § 234.231 Fouling wires. Each set of fouling wires in a highway... single duplex wire with single plug acting as fouling wires is prohibited. Existing installations having...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-09
... Wire Strand from Mexico: Rescission of Antidumping Duty Administrative Review AGENCY: Import... request an administrative review of the antidumping duty order on prestressed concrete steel wire strand... received a timely request from American Spring Wire Corp., Insteel Wire Products Co., and Sumiden Wire...
29 CFR 1926.1413 - Wire rope-inspection.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Apparent deficiencies in this category are: (A) Visible broken wires, as follows: (1) In running wire ropes: Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope... around the rope. (2) In rotation resistant ropes: Two randomly distributed broken wires in six rope...
29 CFR 1926.1413 - Wire rope-inspection.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Apparent deficiencies in this category are: (A) Visible broken wires, as follows: (1) In running wire ropes: Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope... around the rope. (2) In rotation resistant ropes: Two randomly distributed broken wires in six rope...
29 CFR 1926.1413 - Wire rope-inspection.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Apparent deficiencies in this category are: (A) Visible broken wires, as follows: (1) In running wire ropes: Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope... around the rope. (2) In rotation resistant ropes: Two randomly distributed broken wires in six rope...
International space station wire program
NASA Technical Reports Server (NTRS)
May, Todd
1995-01-01
Hardware provider wire systems and current wire insulation issues for the International Space Station (ISS) program are discussed in this viewgraph presentation. Wire insulation issues include silicone wire contamination, Tefzel cold temperature flexibility, and Russian polyimide wire insulation. ISS is a complex program with hardware developed and managed by many countries and hundreds of contractors. Most of the obvious wire insulation issues are known by contractors and have been precluded by proper selection.
U.S. Navy Wire-Rope Handbook. Volume 2. Wire-Rope Analysis and Design Data
1976-01-01
beneficial from the standpoint of wire - bending stress. How- ever, there is a design trade-off here in that the smaller L/d becomes, the lower are the...wires of a rope, it is first necessary to determine the radii of curvature of the wires prior to and after bending the rope. The wire - bending stress can... wire bending stress. 4.3. CONTACT STRESSES Contact stresses in a wire rope are one of the most important determinants of its fatigue life and are, by far
Model-Based Testability Assessment and Directed Troubleshooting of Shuttle Wiring Systems
NASA Technical Reports Server (NTRS)
Deb, Somnath; Domagala, Chuck; Shrestha, Roshan; Malepati, Venkatesh; Cavanaugh, Kevin; Patterson-Hine, Ann; Sanderfer, Dwight; Cockrell, Jim; Norvig, Peter (Technical Monitor)
2000-01-01
We have recently completed a pilot study on the Space shuttle wiring system commissioned by the Wiring Integrity Research (WIRe) team at NASA Ames Research Center, As the space shuttle ages, it is experiencing wiring degradation problems including arcing, chaffing insulation breakdown and broken conductors. A systematic and comprehensive test process is required to thoroughly test and quality assure (QA) the wiring systems. The NASA WIRe team recognized the value of a formal model based analysis for risk-assessment and fault coverage analysis. However. wiring systems are complex and involve over 50,000 wire segments. Therefore, NASA commissioned this pilot study with Qualtech Systems. Inc. (QSI) to explore means of automatically extracting high fidelity multi-signal models from wiring information database for use with QSI's Testability Engineering and Maintenance System (TEAMS) tool.