NASA Astrophysics Data System (ADS)
Badia, Jordi; Boretius, Tim; Andreu, David; Azevedo-Coste, Christine; Stieglitz, Thomas; Navarro, Xavier
2011-06-01
The selection of a suitable nerve electrode for neuroprosthetic applications implies a trade-off between invasiveness and selectivity, wherein the ultimate goal is achieving the highest selectivity for a high number of nerve fascicles by the least invasiveness and potential damage to the nerve. The transverse intrafascicular multichannel electrode (TIME) is intended to be transversally inserted into the peripheral nerve and to be useful to selectively activate subsets of axons in different fascicles within the same nerve. We present a comparative study of TIME, LIFE and multipolar cuff electrodes for the selective stimulation of small nerves. The electrodes were implanted on the rat sciatic nerve, and the activation of gastrocnemius, plantar and tibialis anterior muscles was recorded by EMG signals. Thus, the study allowed us to ascertain the selectivity of stimulation at the interfascicular and also at the intrafascicular level. The results of this study indicate that (1) intrafascicular electrodes (LIFE and TIME) provide excitation circumscribed to the implanted fascicle, whereas extraneural electrodes (cuffs) predominantly excite nerve fascicles located superficially; (2) the minimum threshold for muscle activation with TIME and LIFE was significantly lower than with cuff electrodes; (3) TIME allowed us to selectively activate the three tested muscles when stimulating through different active sites of one device, both at inter- and intrafascicular levels, whereas selective activation using multipolar cuff (with a longitudinal tripolar stimulation configuration) was only possible for two muscles, at the interfascicular level, and LIFE did not activate selectively more than one muscle in the implanted nerve fascicle.
2001-10-25
stimulation techniques. In contrast to epimesial or intramuscular electrodes, the nerve cuff can be placed proximally on the limb to isolate it from the direct...single cuff can be installed proximally on the limb and control several muscles independently, the amount of surgery required to implant electrodes would... neuroprosthetic system and that would obviate the need for the inclusion of one or more IFEs. V. CONCLUSION Results thus far have shown that the inclusion of a
Nielsen, Thomas N; Kurstjens, G A Mathijs; Struijk, Johannes J
2011-04-01
The ability to stimulate subareas of a nerve selectively is highly desirable, since it has the potential of simplifying surgery to implanting one cuff on a large nerve instead of many cuffs on smaller nerves or muscles, or alternatively can improve function where surgical access to the smaller nerves is limited. In this paper, stimulation was performed with a four-channel multipolar cuff electrode implanted on the sciatic nerve of nine rabbits to compare the extensively researched longitudinal tripolar configuration with the transverse tripolar configuration, which has received less interest. The performance of these configurations was evaluated in terms of selectivity in recruitment of the three branches of the sciatic nerve. The results showed that the transverse configuration was able to selectively activate the sciatic nerve branches to a functionally relevant level in more cases than the longitudinal configuration (20/27 versus 11/27 branches) and overall achieved a higher mean selectivity [0.79 ± 0.13 versus 0.61 ± 0.09 (mean ± standard deviation)]. The transverse configuration was most successful at recruiting the small cutaneous and medium-sized peroneal branches, and less successful at recruiting the large tibial nerve.
NASA Astrophysics Data System (ADS)
Sabetian, Parisa; Popovic, Milos R.; Yoo, Paul B.
2017-06-01
Objective. Differential measurement of efferent and afferent peripheral nerve activity offers a promising means of improving the clinical utility of implantable neuroprostheses. The tripolar nerve cuff electrode has historically served as the gold standard for achieving high signal-to-noise ratios (SNRs) of the recordings. However, the symmetrical geometry of this electrode array (i.e. electrically-shorted side contacts) precludes it from measuring electrical signals that can be used to obtain directional information. In this study, we investigated the feasibility of using a bipolar nerve cuff electrode to achieve high-SNR of peripheral nerve activity. Approach. A finite element model was implemented to investigate the effects of electrode design parameters—electrode length, electrode edge length (EEL), and a conductive shielding layer (CSL)—on simulated single fiber action potentials (SFAP) and also artifact noise signals (ANS). Main results. Our model revealed that the EEL was particularly effective in increasing the peak-to-peak amplitude of the SFAP (319%) and reducing the common mode ANS (67%) of the bipolar cuff electrode. By adding a CSL to the bipolar cuff electrode, the SNR was found to be 65.2% greater than that of a conventional tripolar cuff electrode. In vivo experiments in anesthetized rats confirmed that a bipolar cuff electrode can achieve a SNR that is 38% greater than that achieved by a conventional tripolar cuff electrode (p < 0.05). Significance. The current study showed that bipolar nerve cuff electrodes can be designed to achieve SNR levels that are comparable to that of tripolar configuration. Further work is needed to confirm that these bipolar design parameters can be used to record bi-directional neural activity in a physiological setting.
Sabetian, Parisa; Popovic, Milos R; Yoo, Paul B
2017-06-01
Differential measurement of efferent and afferent peripheral nerve activity offers a promising means of improving the clinical utility of implantable neuroprostheses. The tripolar nerve cuff electrode has historically served as the gold standard for achieving high signal-to-noise ratios (SNRs) of the recordings. However, the symmetrical geometry of this electrode array (i.e. electrically-shorted side contacts) precludes it from measuring electrical signals that can be used to obtain directional information. In this study, we investigated the feasibility of using a bipolar nerve cuff electrode to achieve high-SNR of peripheral nerve activity. A finite element model was implemented to investigate the effects of electrode design parameters-electrode length, electrode edge length (EEL), and a conductive shielding layer (CSL)-on simulated single fiber action potentials (SFAP) and also artifact noise signals (ANS). Our model revealed that the EEL was particularly effective in increasing the peak-to-peak amplitude of the SFAP (319%) and reducing the common mode ANS (67%) of the bipolar cuff electrode. By adding a CSL to the bipolar cuff electrode, the SNR was found to be 65.2% greater than that of a conventional tripolar cuff electrode. In vivo experiments in anesthetized rats confirmed that a bipolar cuff electrode can achieve a SNR that is 38% greater than that achieved by a conventional tripolar cuff electrode (p < 0.05). The current study showed that bipolar nerve cuff electrodes can be designed to achieve SNR levels that are comparable to that of tripolar configuration. Further work is needed to confirm that these bipolar design parameters can be used to record bi-directional neural activity in a physiological setting.
An Implantable Neuroprosthetic Device to Normalize Bladder Function after SCI
2013-10-01
we now used 2 separate cuff electrodes (one bipolar and one tripolar , i.e., the electrode #1 and #2 in Fig.1A) to deliver the low and high...Stim. A in Fig.1B) Page 5 and a high frequency (5-20 kHz, 0-11 V) biphasic square waveform (see Fig.1B) to the tripolar cuff electrodes #2 and...sacral spine. Two tripolar cuff electrodes were implanted bilaterally on the pudendal nerves in addition to one bipolar cuff electrode that was
Improving the accuracy of Laplacian estimation with novel multipolar concentric ring electrodes
Ding, Quan; Besio, Walter G.
2015-01-01
Conventional electroencephalography with disc electrodes has major drawbacks including poor spatial resolution, selectivity and low signal-to-noise ratio that are critically limiting its use. Concentric ring electrodes, consisting of several elements including the central disc and a number of concentric rings, are a promising alternative with potential to improve all of the aforementioned aspects significantly. In our previous work, the tripolar concentric ring electrode was successfully used in a wide range of applications demonstrating its superiority to conventional disc electrode, in particular, in accuracy of Laplacian estimation. This paper takes the next step toward further improving the Laplacian estimation with novel multipolar concentric ring electrodes by completing and validating a general approach to estimation of the Laplacian for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method for n ≥ 2 that allows cancellation of all the truncation terms up to the order of 2n. An explicit formula based on inversion of a square Vandermonde matrix is derived to make computation of multipolar Laplacian more efficient. To confirm the analytic result of the accuracy of Laplacian estimate increasing with the increase of n and to assess the significance of this gain in accuracy for practical applications finite element method model analysis has been performed. Multipolar concentric ring electrode configurations with n ranging from 1 ring (bipolar electrode configuration) to 6 rings (septapolar electrode configuration) were directly compared and obtained results suggest the significance of the increase in Laplacian accuracy caused by increase of n. PMID:26693200
Improving the accuracy of Laplacian estimation with novel multipolar concentric ring electrodes.
Makeyev, Oleksandr; Ding, Quan; Besio, Walter G
2016-02-01
Conventional electroencephalography with disc electrodes has major drawbacks including poor spatial resolution, selectivity and low signal-to-noise ratio that are critically limiting its use. Concentric ring electrodes, consisting of several elements including the central disc and a number of concentric rings, are a promising alternative with potential to improve all of the aforementioned aspects significantly. In our previous work, the tripolar concentric ring electrode was successfully used in a wide range of applications demonstrating its superiority to conventional disc electrode, in particular, in accuracy of Laplacian estimation. This paper takes the next step toward further improving the Laplacian estimation with novel multipolar concentric ring electrodes by completing and validating a general approach to estimation of the Laplacian for an ( n + 1)-polar electrode with n rings using the (4 n + 1)-point method for n ≥ 2 that allows cancellation of all the truncation terms up to the order of 2 n . An explicit formula based on inversion of a square Vandermonde matrix is derived to make computation of multipolar Laplacian more efficient. To confirm the analytic result of the accuracy of Laplacian estimate increasing with the increase of n and to assess the significance of this gain in accuracy for practical applications finite element method model analysis has been performed. Multipolar concentric ring electrode configurations with n ranging from 1 ring (bipolar electrode configuration) to 6 rings (septapolar electrode configuration) were directly compared and obtained results suggest the significance of the increase in Laplacian accuracy caused by increase of n .
Effects of the choice of reference on the selectivity of a multi-contact nerve cuff electrode.
Koh, Ryan G L; Zariffa, Jose
2016-08-01
Tripolar referencing is typically used in nerve cuff electrode recordings due to its ability to maximize the signal-to-noise ratio of contacts at the centre, but this may not be the optimal choice for a multi-contact nerve cuff consisting of contacts in off-centre rings. We conducted a simulation study to compare the effects of 3 different reference types on the recording selectivity of a multi-contact nerve cuff: the tripolar reference (TPR), common average reference (CAR), and multiple tripolar references based on consecutive groups of 3 rings (cTPR). For this purpose, we introduce a novel measure called the contact information metric (CIM). Selectivity was tested in 2 noise settings, one in which white Gaussian noise was added inside the nerve cuff electrode and the other in which electromyogram (EMG) noise was added outside the nerve cuff electrode. The mean CIMs values calculated for the best 8 contacts were 3.42±6.25, 2.70±3.37, and 3.65±1.90 for the TPR, the CAR and the cTPR, respectively, in the case of EMG noise added outside the nerve cuff electrode. This study shows that the use of cTPR reference is the optimal choice for selectivity when using a multi-contact nerve cuff electrode which contains off-centre rings.
Effect of contacts configuration and location on selective stimulation of cuff electrode.
Taghipour-Farshi, Hamed; Frounchi, Javad; Ahmadiasl, Nasser; Shahabi, Parviz; Salekzamani, Yaghoub
2015-01-01
Cuff electrodes have been widely used chronically in different clinical applications. Advancements have been made in selective stimulation by using multi-contact cuff electrodes. Steering anodic current is a strategy to increase selectivity by reshaping and localizing electric fields. There are two configurations for contacts to be implemented in cuff, monopolar and tripolar. A cuff electrode with tripolar configuration can restrict the activation to a more localized region within a nerve trunk compared to a cuff with monopolar configuration and improve the selectivity. Anode contacts in tripolar configuration can be made in two structures, "ring" and "dot". In this study, the stimulation capabilities of these two structures were evaluated. The recruitment properties and the selectivity of stimulation were examined by measuring the electric potential produced by stimulation currents. The results of the present study indicated that using dot configuration, the current needed to stimulate fascicles in tripolar topologies would be reduced by 10%. It was also shown that stimulation threshold was increased by moving anode contacts inward the cuff. On the other hand, stimulation threshold was decreased by moving the anode contacts outward the cuff which would decrease selectivity, too. We conclude that dot configuration is a better choice for stimulation. Also, a cuff inward placement of 10% relative to the cuff length was near optimal.
Reducing Stiffness and Electrical Losses of High Channel Hybrid Nerve Cuff Electrodes
2001-10-25
Electrodes were developed. These electrodes consisted of a micromachined polyimide -based thin-film structure with integrated electrode contacts and...electrodes, mechanical properties were enhanced by changing the method of joining silicone and polyimide from using one part silicone adhesive to...gold, platinum, platinum black, polyimide , silicone, polymer bonding I. INTRODUCTION Cuff-type electrodes are probably the most commonly used neural
Comparison of joint torque evoked with monopolar and tripolar-cuff electrodes.
Tarler, Matthew D; Mortimer, J Thomas
2003-09-01
Using a self-sizing spiral-cuff electrode placed on the sciatic nerve of the cat, the joint torque evoked with stimulation applied to contacts in a monopolar configuration was judged to be the same as the torque evoked by stimulation applied to contacts in a tripolar configuration. Experiments were carried out in six acute cat preparations. In each experiment, a 12-contact electrode was placed on the sciatic nerve and used to effect both the monopolar and tripolar electrode configurations. The ankle torque produced by electrically evoked isometric muscle contraction was measured in three dimensions: plantar flexion, internal rotation, and inversion. Based on the recorded ankle torque, qualitative and quantitative comparisons were performed to determine if any significant difference existed in the pattern or order in which motor nerve fibers were recruited. No significant difference was found at a 98% confidence interval in either the recruitment properties or the repeatability of the monopolar and tripolar configurations. Further, isolated activation of single fascicles within the sciatic nerve was observed. Once nerve fibers in a fascicle were activated, recruitment of that fascicle was modulated over the full range before "spill-over" excitation occurred in neighboring fascicles. These results indicate that a four contact, monopolar nerve-cuff electrode is a viable substitute for a 12 contact, tripolar nerve-cuff electrode. The results of this study are also consistent with the hypothesis that multicontact self-sizing spiral-cuff electrodes can be used in motor prostheses to provide selective control of many muscles. These findings should also apply to other neuroprostheses employing-cuff electrodes on nerve trunks.
Sabetian, Parisa; Sadeghlo, Bita; Zhang, Chengran Harvey; Yoo, Paul B
2017-02-01
Tripolar nerve cuff electrodes have been widely used for measuring peripheral nerve activity. However, despite the high signal-to-noise ratio levels that can be achieved with this recording configuration, the clinical use of cuff electrodes in closed-loop controlled neuroprostheses remains limited. This is largely attributed to artifact noise signals that contaminate the recorded neural activity. In this study, we investigated the use of a conductive shield layer (CSL) as a means of reducing the artifact noise recorded by nerve cuff electrodes. Using both computational simulations and in vivo experiments, we found that the CSL can result in up to an 85% decrease in the recorded artifact signal. Both the electrical conductivity and the surface area of the CSL were identified as important design criteria. Although this study shows that the CSL can significantly reduce artifact noise in tripolar nerve cuff electrodes, long-term implant studies are needed to validate our findings. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Toward improving the Laplacian estimation with novel multipolar concentric ring electrodes.
Makeyev, Oleksandr; Ding, Quan; Kay, Steven M; Besio, Walter G
2013-01-01
Conventional electroencephalography with disc electrodes has major drawbacks including poor spatial resolution, selectivity and low signal-to-noise ratio that are critically limiting its use. Concentric ring electrodes are a promising alternative with potential to improve all of the aforementioned aspects significantly. In our previous work, the tripolar concentric ring electrode was successfully used in a wide range of applications demonstrating its superiority to conventional disc electrode, in particular, in accuracy of Laplacian estimation. This paper takes the first fundamental step toward further improving the Laplacian estimation of the novel multipolar concentric ring electrodes by proposing a general approach to estimation of the Laplacian for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method for n ≥ 2 that allows cancellation of all the truncation terms up to the order of 2n. Examples of using the proposed approach to estimate the Laplacian for the cases of tripolar and, for the first time, quadripolar concentric ring electrode are presented.
Silicone Molding and Lifetime Testing of Peripheral Nerve Interfaces for Neuroprostheses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupte, Kimaya; Tolosa, Vanessa
Implantable peripheral nerve cuffs have a large application in neuroprostheses as they can be used to restore sensation to those with upper limb amputations. Modern day prosthetics, while lessening the pain associated with phantom limb syndrome, have limited fine motor control and do not provide sensory feedback to patients. Sensory feedback with prosthetics requires communication between the nervous system and limbs, and is still a challenge to accomplish with amputees. Establishing this communication between the peripheral nerves in the arm and artificial limbs is vital as prosthetics research aims to provide sensory feedback to amputees. Peripheral nerve cuffs restore sensationmore » by electrically stimulating certain parts of the nerve in order to create feeling in the hand. Cuff electrodes have an advantage over standard electrodes as they have high selective stimulation by bringing the electrical interface close to the neural tissue in order to selectively activate targeted regions of a peripheral nerve. In order to further improve the selective stimulation of these nerve cuffs, there is need for finer spatial resolution among electrodes. One method to achieve a higher spatial resolution is to increase the electrode density on the cuff itself. Microfabrication techniques can be used to achieve this higher electrode density. Using L-Edit, a layout editor, microfabricated peripheral nerve cuffs were designed with a higher electrode density than the current model. This increase in electrode density translates to an increase in spatial resolution by at least one order of magnitude. Microfabricated devices also have two separate components that are necessary to understand before implantation: lifetime of the device and assembly to prevent nerve damage. Silicone molding procedures were optimized so that devices do not damage nerves in vivo, and lifetime testing was performed on test microfabricated devices to determine their lifetime in vivo. Future work of this project would include fabricating some of the designed devices and seeing how they compare to the current cuffs in terms of their electrical performance, lifetime, shape, and mechanical properties.« less
Nerve cuff electrode using embedded magnets and its application to hypoglossal nerve stimulation.
Seo, Jungmin; Wee, Jee Hye; Park, Jeong Hoan; Park, Pona; Kim, Jeong-Whun; Kim, Sung June
2016-12-01
A novel nerve cuff electrode with embedded magnets was fabricated and developed. In this study, a pair of magnets was fully embedded and encapsulated in a liquid crystal polymer (LCP) substrate to utilize magnetic force in order to replace the conventional installing techniques of cuff electrodes. In vitro and in vivo experiments were conducted to evaluate the feasibility of the magnet-embedded nerve cuff electrode (MENCE). Lastly, several issues pertaining to the MENCE such as the cuff-to-nerve diameter ratio, the force of the magnets, and possible concerns were discussed in the discussion section. Electrochemical impedance spectrum and cyclic voltammetry assessments were conducted to measure the impedance and charge storage capacity of the cathodal phase (CSC c ). The MENCE was installed onto the hypoglossal nerve (HN) of a rabbit and the movement of the genioglossus was recorded through C-arm fluoroscopy while the HN was stimulated by a pulsed current. The measured impedance was 0.638 ∠ -67.8° kΩ at 1 kHz and 5.27 ∠ -82.1° kΩ at 100 Hz. The average values of access resistance and cut-off frequency were 0.145 kΩ and 3.98 kHz, respectively. The CSC c of the electrode was measured as 1.69 mC cm -2 at the scan rate of 1 mV s -1 . The movement of the genioglossus contraction was observed under a pulsed current with an amplitude level of 0.106 mA, a rate of 0.635 kHz, and a duration of 0.375 ms applied through the MENCE. A few methods to close and secure cuff electrodes have been researched, but they are associated with several drawbacks. To overcome these, we used magnetic force as a closing method of the cuff electrode. The MENCE can be precisely installed on a target nerve without any surgical techniques such as suturing or molding. Furthermore, it is convenient to remove the installed MENCE because it requires little force to detach one magnet from the other, enabling repeatable installation and removal. We anticipate that the MENCE will become a very useful tool given its unique properties as a cuff electrode for neural engineering.
Dweiri, Yazan M; Stone, Matthew A; Tyler, Dustin J; McCallum, Grant A; Durand, Dominique M
2016-10-04
Many attempts have been made to manufacture multi-contact nerve cuff electrodes that are safe, robust and reliable for long term neuroprosthetic applications. This protocol describes a fabrication technique of a modified cylindrical nerve cuff electrode to meet these criteria. Minimum computer-aided design and manufacturing (CAD and CAM) skills are necessary to consistently produce cuffs with high precision (contact placement 0.51 ± 0.04 mm) and various cuff sizes. The precision in spatially distributing the contacts and the ability to retain a predefined geometry accomplished with this design are two criteria essential to optimize the cuff's interface for selective recording and stimulation. The presented design also maximizes the flexibility in the longitudinal direction while maintaining sufficient rigidity in the transverse direction to reshape the nerve by using materials with different elasticities. The expansion of the cuff's cross sectional area as a result of increasing the pressure inside the cuff was observed to be 25% at 67 mm Hg. This test demonstrates the flexibility of the cuff and its response to nerve swelling post-implant. The stability of the contacts' interface and recording quality were also examined with contacts' impedance and signal-to-noise ratio metrics from a chronically implanted cuff (7.5 months), and observed to be 2.55 ± 0.25 kΩ and 5.10 ± 0.81 dB respectively.
Fisher, L E; Tyler, D J; Anderson, J S; Triolo, R J
2009-08-01
This study describes the stability and selectivity of four-contact spiral nerve-cuff electrodes implanted bilaterally on distal branches of the femoral nerves of a human volunteer with spinal cord injury as part of a neuroprosthesis for standing and transfers. Stimulation charge threshold, the minimum charge required to elicit a visible muscle contraction, was consistent and low (mean threshold charge at 63 weeks post-implantation: 23.3 +/- 8.5 nC) for all nerve-cuff electrode contacts over 63 weeks after implantation, indicating a stable interface with the peripheral nervous system. The ability of individual nerve-cuff electrode contacts to selectively stimulate separate components of the femoral nerve to activate individual heads of the quadriceps was assessed with fine-wire intramuscular electromyography while measuring isometric twitch knee extension moment. Six of eight electrode contacts could selectively activate one head of the quadriceps while selectively excluding others to produce maximum twitch responses of between 3.8 and 8.1 N m. The relationship between isometric twitch and tetanic knee extension moment was quantified, and selective twitch muscle responses scaled to between 15 and 35 N m in tetanic response to pulse trains with similar stimulation parameters. These results suggest that this nerve-cuff electrode can be an effective and chronically stable tool for selectively stimulating distal nerve branches in the lower extremities for neuroprosthetic applications.
Fisher, L E; Tyler, D J; Anderson, J S; Triolo, R J
2010-01-01
This study describes the stability and selectivity of four-contact spiral nerve-cuff electrodes implanted bilaterally on distal branches of the femoral nerves of a human volunteer with spinal cord injury as part of a neuroprosthesis for standing and transfers. Stimulation charge threshold, the minimum charge required to elicit a visible muscle contraction, was consistent and low (mean threshold charge at 63 weeks post-implantation: 23.3 ± 8.5 nC) for all nerve-cuff electrode contacts over 63 weeks after implantation, indicating a stable interface with the peripheral nervous system. The ability of individual nerve-cuff electrode contacts to selectively stimulate separate components of the femoral nerve to activate individual heads of the quadriceps was assessed with fine-wire intramuscular electromyography while measuring isometric twitch knee extension moment. Six of eight electrode contacts could selectively activate one head of the quadriceps while selectively excluding others to produce maximum twitch responses of between 3.8 and 8.1 Nm. The relationship between isometric twitch and tetanic knee extension moment was quantified, and selective twitch muscle responses scaled to between 15 and 35 Nm in tetanic response to pulse trains with similar stimulation parameters. These results suggest that this nerve-cuff electrode can be an effective and chronically stable tool for selectively stimulating distal nerve branches in the lower extremities for neuroprosthetic applications. PMID:19602729
A New Pulse Shape to Obtain Selective Small Fiber Activation by Anodal Blocking
2001-10-25
anodal blocking a tripolar cuff electrode is most commonly used. When external stimulation is applied, the fiber membrane is depolarized close to...would be safer if somehow the charge per phase could be reduced. Charge reduction might be possible with the following idea: In a tripolar cuff...inhomogeneous and anisotropic volume conductor model [3]. A symmetrical tripolar cuff electrode with an inner diameter of 2 mm was placed around a
Recording of electroneurograms from the nerves innervating the pancreas of a dog.
Rozman, J; Zorko, B; Bunc, M
2001-12-15
Electroneurograms (ENGs) from the vagus, splanchnic and pancreatic nerves innervating the pancreas of a dog, were recorded with chronically implanted silicone multi-electrode circular cuffs in an intact pancreas and in a pancreas partly disabled with alloxan. The cuffs contained 33 platinum electrodes (0.6x1.5 mm) arranged in three parallel circular groups integrated into the inner surface of the cuff. Each circular group contained 11 electrodes at a distance of 0.5 mm apart, with 6 mm between the circular groups. The cuffs had an inner diameter of 2.5 mm and the length of 18 mm. In a 2-year study, the cuffs were implanted into two adult Beagle dogs (one female and one male). In the vagus nerve, the cuff was installed on the nerve at the neck, whilst in the splanchnic nerve, the cuff was installed on the nerve before the celiac ganglion, and in the pancreatic nerve, the cuff was installed on the nerve just before it enters the pancreas. In each of the three implanted cuffs, the electrodes of the central circular group were connected to each other and this signal provided one input to a multi-channel ENG amplifying system. The electrodes of each of the two outer spiral groups were connected to each other and then both these groups were short-circuited. This signal then provided another input to the multi-channel ENG amplifying system. The ENG amplifying system was designed to amplify the ENGs 100000 times and to pass frequencies of between 500 and 10 kHz. In our study, three recordings in each animal were conducted. Recordings in the intact pancreas were conducted 2 and 6 months after the implantation, while the recording in the partly disabled pancreas, was conducted 10 months after the implantation and 10 days after the disablement. Due to the fact that the results obtained in both animals were actually quite similar, we present the results of the recordings obtained in one animal. In both animals the cuffs were left implanted for more than 1 year and were used for pancreatic stimulation, although this is not in this paper. The results show that cuffs implanted chronically on the nerves innervating the pancreas of a dog could reliably record the ENGs. This information could be used effectively in further study of pancreatic innervation and its function. Moreover, the results suggest that cuffs could also be useful in recording the ENGs from other nerves of the autonomic nervous system that innervate various glands and internal organs.
"Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves".
Christie, Breanne P; Freeberg, Max; Memberg, William D; Pinault, Gilles J C; Hoyen, Harry A; Tyler, Dustin J; Triolo, Ronald J
2017-07-11
Electrical stimulation of the peripheral nerves has been shown to be effective in restoring sensory and motor functions in the lower and upper extremities. This neural stimulation can be applied via non-penetrating spiral nerve cuff electrodes, though minimal information has been published regarding their long-term performance for multiple years after implantation. Since 2005, 14 human volunteers with cervical or thoracic spinal cord injuries, or upper limb amputation, were chronically implanted with a total of 50 spiral nerve cuff electrodes on 10 different nerves (mean time post-implant 6.7 ± 3.1 years). The primary outcome measures utilized in this study were muscle recruitment curves, charge thresholds, and percent overlap of recruited motor unit populations. In the eight recipients still actively involved in research studies, 44/45 of the spiral contacts were still functional. In four participants regularly studied over the course of 1 month to 10.4 years, the charge thresholds of the majority of individual contacts remained stable over time. The four participants with spiral cuffs on their femoral nerves were all able to generate sufficient moment to keep the knees locked during standing after 2-4.5 years. The dorsiflexion moment produced by all four fibular nerve cuffs in the active participants exceeded the value required to prevent foot drop, but no tibial nerve cuffs were able to meet the plantarflexion moment that occurs during push-off at a normal walking speed. The selectivity of two multi-contact spiral cuffs was examined and both were still highly selective for different motor unit populations for up to 6.3 years after implantation. The spiral nerve cuffs examined remain functional in motor and sensory neuroprostheses for 2-11 years after implantation. They exhibit stable charge thresholds, clinically relevant recruitment properties, and functional muscle selectivity. Non-penetrating spiral nerve cuff electrodes appear to be a suitable option for long-term clinical use on human peripheral nerves in implanted neuroprostheses.
Radiofrequency ablation of hepatocellular carcinoma: Mono or multipolar?
Cartier, Victoire; Boursier, Jérôme; Lebigot, Jérôme; Oberti, Frédéric; Fouchard-Hubert, Isabelle; Aubé, Christophe
2016-03-01
Thermo-ablation by radiofrequency is recognized as a curative treatment for early-stage hepatocellular carcinoma. However, local recurrence may occur because of incomplete peripheral tumor destruction. Multipolar radiofrequency has been developed to increase the size of the maximal ablation zone. We aimed to compare the efficacy of monopolar and multipolar radiofrequency for the treatment of hepatocellular carcinoma and determine factors predicting failure. A total of 171 consecutive patients with 214 hepatocellular carcinomas were retrospectively included. One hundred fifty-eight tumors were treated with an expandable monopolar electrode and 56 with a multipolar technique using several linear bipolar electrodes. Imaging studies at 6 weeks after treatment, then every 3 months, assessed local effectiveness. Radiofrequency failure was defined as persistent residual tumor after two sessions (primary radiofrequency failure) or local tumor recurrence during follow-up. This study received institutional review board approval (number 2014/77). Imaging showed complete tumor ablation in 207 of 214 lesions after the first session of radiofrequency. After a second session, only two cases of residual viable tumor were observed. During follow-up, there were 46 local tumor recurrences. Thus, radiofrequency failure occurred in 48/214 (22.4%) cases. By multivariate analysis, technique (P < 0.001) and tumor size (P = 0.023) were independent predictors of radiofrequency failure. Failure rate was lower with the multipolar technique for tumors < 25 mm (P = 0.023) and for tumors between 25 and 45 mm (P = 0.082). There was no difference for tumors ≥ 45 mm (P = 0.552). Compared to monopolar radiofrequency, multipolar radiofrequency improves tumor ablation with a subsequent lower rate of local tumor recurrence. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Biomechanical and functional variation in rat sciatic nerve following cuff electrode implantation
2014-01-01
Background Nerve cuff electrodes are commonly and successfully used for stimulating peripheral nerves. On the other hand, they occasionally induce functional and morphological changes following chronic implantation, for reasons not always clear. We hypothesize that restriction of nerve mobility due to cuff implantation may alter nerve conduction. Methods We quantified acute changes in nerve-muscle electrophysiology, using electromyography, and nerve kinematics in anesthetized Sprague Dawley rat sciatic nerves during controlled hindlimb joint movement. We compared electrophysiological and biomechanical response in uncuffed nerves and those secured within a cuff electrode using analysis of variance (ANOVA) and regression analysis. Results Tethering resulting from cuff implantation resulted in altered nerve strain and a complex biomechanical environment during joint movement. Coincident with biomechanical changes, electromyography revealed significantly increased variability in the response of conduction latency and amplitude in cuffed, but not free, nerves following joint movement. Conclusion Our findings emphasize the importance of the mechanical interface between peripheral nerves and their devices on neurophysiological performance. This work has implications for nerve device design, implantation, and prediction of long-term efficacy. PMID:24758405
A device for emulating cuff recordings of action potentials propagating along peripheral nerves.
Rieger, Robert; Schuettler, Martin; Chuang, Sheng-Chih
2014-09-01
This paper describes a device that emulates propagation of action potentials along a peripheral nerve, suitable for reproducible testing of bio-potential recording systems using nerve cuff electrodes. The system is a microcontroller-based stand-alone instrument which uses established nerve and electrode models to represent neural activity of real nerves recorded with a nerve cuff interface, taking into consideration electrode impedance, voltages picked up by the electrodes, and action potential propagation characteristics. The system emulates different scenarios including compound action potentials with selectable propagation velocities and naturally occurring nerve traffic from different velocity fiber populations. Measured results from a prototype implementation are reported and compared with in vitro recordings from Xenopus Laevis frog sciatic nerve, demonstrating that the electrophysiological setting is represented to a satisfactory degree, useful for the development, optimization and characterization of future recording systems.
NASA Astrophysics Data System (ADS)
Dupas-Bruzek, C.; Dréan, P.; Derozier, D.
2009-10-01
Chronic nerve recording and stimulation became possible through the use of implanted electrodes cuffs. In particular, self-sizing spiral electrode cuffs limit mechanical damage to the tissue: these have been shown to be suitable for long term implantation in animal and in man. However, up to now, such electrode cuffs were handmade and were hardly reproducible. They possessed a small number of electrodes (dot contacts), each being linked to its own wire. In order to improve the selectivity of nerve recording and/or stimulation (functional electrical stimulation), the numbers of electrodes and tracks have to be increased within the same electrode cuff surface. To fulfill this requirement, we have developed a fabrication process that uses an UV laser to induce surface modification, which activates the silicone rubber and is used with a mask to give high definition tracks and electrodes. After this primary step, silicone rubber is immersed in a Pt autocatalytic bath leading to a selective Pt metallization of the laser activated tracks and electrodes. We report our process as well as the results on the Pt metallization, including its morphology, how the DC resistance of Pt tracks depends on the laser used and the irradiation conditions, and also the electrical resistance of Pt tracks submitted to Scotch tape tests or to imposed strains. We show that (i) the type of laser and the irradiation conditions have a strong influence on the nucleation and growth rate of platinum and thus on the DC resistance of the tracks, (ii) the tracks of width 400 μm and thickness 10 μm have a sheet resistivity of 0.2 Ω/sq, (iii) DC resistance does not change much during a 6 month soak in saline, (iv) strains above 2% breaks the track continuity, and (v) when strains below 53% are relaxed, the DC resistance returns to a low value. This recovery from large tensile strains means that nerve cuffs with such metallization could be handled by the surgeon without great care before and during implantation.
Evaluation of high-density, multi-contact nerve cuffs for activation of grasp muscles in monkeys
NASA Astrophysics Data System (ADS)
Brill, N. A.; Naufel, S. N.; Polasek, K.; Ethier, C.; Cheesborough, J.; Agnew, S.; Miller, L. E.; Tyler, D. J.
2018-06-01
Objective. The objective of this work was to evaluate whether nerve cuffs can selectively activate hand muscles for functional electrical stimulation (FES). FES typically involves identifying and implanting electrodes in many individual muscles, but nerve cuffs only require implantation at a single site around the nerve. This method is surgically more attractive. Nerve cuffs may also more effectively stimulate intrinsic hand muscles, which are difficult to implant and stimulate without spillover to adjacent muscles. Approach. To evaluate its ability to selectively activate muscles, we implanted and tested the flat interface nerve electrode (FINE), which is designed to selectively stimulate peripheral nerves that innervate multiple muscles (Tyler and Durand 2002 IEEE Trans. Neural Syst. Rehabil. Eng. 10 294-303). We implanted FINEs on the nerves and bipolar intramuscular wires for recording compound muscle action potentials (CMAPs) from up to 20 muscles in each arm of six monkeys. We then collected recruitment curves while the animals were anesthetized. Main result. A single FINE implanted on an upper extremity nerve in the monkey can selectively activate muscles or small groups of muscles to produce multiple, independent hand functions. Significance. FINE cuffs can serve as a viable supplement to intramuscular electrodes in FES systems, where they can better activate intrinsic and extrinsic muscles with lower currents and less extensive surgery.
Blana, Dimitra; Hincapie, Juan G; Chadwick, Edward K; Kirsch, Robert F
2013-01-01
Neuroprosthetic systems based on functional electrical stimulation aim to restore motor function to individuals with paralysis following spinal cord injury. Identifying the optimal electrode set for the neuroprosthesis is complicated because it depends on the characteristics of the individual (such as injury level), the force capacities of the muscles, the movements the system aims to restore, and the hardware limitations (number and type of electrodes available). An electrode-selection method has been developed that uses a customized musculoskeletal model. Candidate electrode sets are created based on desired functional outcomes and the hard ware limitations of the proposed system. Inverse-dynamic simulations are performed to determine the proportion of target movements that can be accomplished with each set; the set that allows the most movements to be performed is chosen as the optimal set. The technique is demonstrated here for a system recently developed by our research group to restore whole-arm movement to individuals with high-level tetraplegia. The optimal set included selective nerve-cuff electrodes for the radial and musculocutaneous nerves; single-channel cuffs for the axillary, suprascapular, upper subscapular, and long-thoracic nerves; and muscle-based electrodes for the remaining channels. The importance of functional goals, hardware limitations, muscle and nerve anatomy, and surgical feasibility are highlighted.
An improved method of crafting a multi-electrode spiral cuff for the selective.
Rozman, Janez; Pečlin, Polona; Ribarič, Samo; Godec, Matjaž; Burja, Jaka
2018-01-17
This article reviews an improved methodology and technology for crafting a multi-electrode spiral cuff for the selective activation of nerve fibres in particular superficial regions of a peripheral nerve. The analysis, structural and mechanical properties of the spot welds used for the interconnections between the stimulating electrodes and stainless-steel lead wires are presented. The cuff consisted of 33 platinum electrodes embedded within a self-curling 17-mm-long silicone spiral sheet with a nominal internal diameter of 2.5 mm. The weld was analyzed using scanning electron microscopy and nanohardness tests, while the interconnection was investigated using destructive load tests. The functionality of the cuff was tested in an isolated porcine vagus nerve. The results of the scanning electron microscopy show good alloying and none of the typical welding defects that occur between the wire and the platinum foil. The results of the destructive load tests show that the breaking loads were between 3.22 and 5 N. The results of the nanohardness testing show that the hardness of the weld was different for the particular sites on the weld sample. Finally, the results of the functional testing show that for different stimulation intensities both the compound action potential deflection and the shape are modulated.
Combined electric and pressure cuff pain stimuli for assessing conditioning pain modulation (CPM).
Tsukamoto, M; Petersen, K K; Mørch, C D; Arendt-Nielsen, L
2017-12-29
Aims Traditionally, conditioning pain modulation (CPM) can be assessed by applying a test stimulus (TS) before and after application of a conditioning stimulus (CS), which is normally applied extra-segmental. Currently, no studies have attempted to apply the TS and CS to the same site using different stimuli modalities. The aim of this study was to evaluate electrical TS and cuff pressure CS applied to the same experimental site for studying CPM. Methods 20 male volunteers participated in this study, which consisted of stimulations applied by a cuff-algometer (NociTech and Aalborg University, Denmark) and current stimulator (Digitimer DS5, UK), through two Ag/AgCl electrodes (Ambu® Neuroline 700, Denmark). The cuff was wrapped around the lower leg and stimulation electrodes were placed under the cuff and to the same location on the contralateral leg. Electrical TS were applied to the non-dominant leg with or without cuff pressure CS on the dominant (CS1) or the same (non-dominant) leg (CS2, electrode under cuff). The subjects were instructed to rate the electrical evoked pain intensity on a 10-cm continuous visual analog scale (VAS, "0" represented "no pain", and "10" represented "maximal pain"). The pain detection threshold (PDT) was defined as "1" on the VAS scale. Results There was no significant deference in PDT for neither CS1 nor CS2. A median split subanalysis on CPM-responders versus CPM-nonresponders to the TS + CS1 combination. Using this grouping, there was significant increase in PDT when comparing TS to TS + CS1 or TS + CS2 (4.0 mA vs 5.6 mA; P < 0.05, 4.0 mA vs 5.1 mA; P < 0.05). Conclusions The study indicates that CPM can be evoked in a subgroup of subjects by applying the electrical test stimulus and cuff pressure conditioning stimuli to the same experimental site.
Wavelet Packet Analysis for Angular Data Extraction from Muscle Afferent Cuff Electrode Signals
2001-10-25
from rabbits. In order to estimate ankle flexion/extension angles, we recorded ENG signals from the left Tibial and Peroneal nerves, both during FES...afferent ENG. II. METHODOLOGY A. Experimental Setup Acute experiments were conducted with 2 female New Zealand rabbits. The rabbits were pre-anesthetized...fixating the knee and ankle joints in place (see [3] for more details) . For extracting the ENG signals, tripolar cuff electrodes were implanted onto the
NASA Astrophysics Data System (ADS)
Crook, J. J.; Brouillard, C. B. J.; Irazoqui, P. P.; Lovick, T. A.
2018-04-01
Objective. Neuromodulation of autonomic nerve activity to regulate physiological processes is an emerging field. Vagal stimulation has received most attention whereas the potential of modulate visceral function by targeting autonomic nerves within the abdominal cavity remains under-exploited. Surgery to locate intra-abdominal targets is inherently more stressful than for peripheral nerves. Electrode leads risk becoming entrapped by intestines and loss of functionality in the nerve-target organ connection could result from electrode migration or twisting. Since nociceptor afferents are intermingled with similar-sized visceral autonomic fibres, stimulation may induce pain. In anaesthetised rats high frequency stimulation of the pelvic nerve can suppress urinary voiding but it is not known how conscious animals would react to this procedure. Our objective therefore was to determine how rats tolerated chronic implantation of cuff electrodes on the pelvic nerve, whether nerve stimulation would be aversive and whether nerve-bladder functionality would be compromised. Approach. We carried out a preliminary de-risking study to investigate how conscious rats tolerated chronic implantation of electrodes on the pelvic nerve, their responsiveness to intermittent high frequency stimulation and whether functionality of the nerve-bladder connection became compromised. Main results. Implantation of cuff electrodes was well-tolerated. The normal diurnal pattern of urinary voiding was not disrupted. Pelvic nerve stimulation (up to 4 mA, 3 kHz) for 30 min periods evoked mild alerting at stimulus onset but no signs of pain. Stimulation evoked a modest (<0.5 °C) increase in nerve temperature but the functional integrity of the nerve-bladder connection, reflected by contraction of the detrusor muscle in response to 10 Hz nerve stimulation, was not compromised. Significance. Chronic implantation of cuff electrodes on the pelvic nerve was found to be a well-tolerated procedure in rats and high frequency stimulation did not lead to loss of nerve functionality. Pelvic nerve stimulation has development potential for normalizing voiding dysfunction in conscious rats.
Biocompatibility of platinum-metallized silicone rubber: in vivo and in vitro evaluation.
Vince, V; Thil, M A; Veraart, C; Colin, I M; Delbeke, J
2004-01-01
Silicone rubber is commonly used for biomedical applications, including implanted cuff electrodes for both recording and stimulation of peripheral nerves. This study was undertaken to evaluate the consequences of a new platinum metallization method on the biocompatibility of silicone rubber cuff electrodes. This method was introduced in order to allow the manufacture of spiral nerve cuff electrodes with a large number of contacts. The metallization process, implying silicone coating with poly(methyl methacrylate) (PMMA), its activation by an excimer laser and subsequent electroless metal deposition, led to a new surface microtexture. The neutral red cytotoxicity assay procedure was first applied in vitro on BALB/c 3T3 fibroblasts in order to analyze the cellular response elicited by the studied material. An in vivo assay was then performed to investigate the tissue reaction after chronic subcutaneous implantation of the metallized material. Results demonstrate that silicone rubber biocompatibility is not altered by the new platinum metallization method.
Pudendal nerve stimulation and block by a wireless-controlled implantable stimulator in cats.
Yang, Guangning; Wang, Jicheng; Shen, Bing; Roppolo, James R; de Groat, William C; Tai, Changfeng
2014-07-01
The study aims to determine the functionality of a wireless-controlled implantable stimulator designed for stimulation and block of the pudendal nerve. In five cats under α-chloralose anesthesia, the stimulator was implanted underneath the skin on the left side in the lower back along the sacral spine. Two tripolar cuff electrodes were implanted bilaterally on the pudendal nerves in addition to one bipolar cuff electrode that was implanted on the left side central to the tripolar cuff electrode. The stimulator provided high-frequency (5-20 kHz) biphasic stimulation waveforms to the two tripolar electrodes and low-frequency (1-100 Hz) rectangular pulses to the bipolar electrode. Bladder and urethral pressures were measured to determine the effects of pudendal nerve stimulation (PNS) or block. The maximal (70-100 cmH2O) urethral pressure generated by 20-Hz PNS applied via the bipolar electrode was completely eliminated by the pudendal nerve block induced by the high-frequency stimulation (6-15 kHz, 6-10 V) applied via the two tripolar electrodes. In a partially filled bladder, 20-30 Hz PNS (2-8 V, 0.2 ms) but not 5 Hz stimulation applied via the bipolar electrode elicited a large sustained bladder contraction (45.9 ± 13.4 to 52.0 ± 22 cmH2O). During cystometry, the 5 Hz PNS significantly (p < 0.05) increased bladder capacity to 176.5 ± 27.1% of control capacity. The wireless-controlled implantable stimulator successfully generated the required waveforms for stimulation and block of pudendal nerve, which will be useful for restoring bladder functions after spinal cord injury. © 2013 International Neuromodulation Society.
Model-based evaluation of the short-circuited tripolar cuff configuration.
Andreasen, Lotte N S; Struijk, Johannes J
2006-05-01
Recordings of neural information for use as feedback in functional electrical stimulation are often contaminated with interfering signals from muscles and from stimulus pulses. The cuff electrode used for the neural recording can be optimized to improve the S/I ratio. In this work, we evaluate a model of both the nerve signal and the interfering signals recorded by a cuff, and subsequently use this model to study the signal to interference ratio of different cuff designs and to evaluate a recently introduced short-circuited tripolar cuff configuration. The results of the model showed good agreement with results from measurements in rabbits and confirmed the superior performance of the short-circuited tripolar configuration as compared with the traditionally used tripolar configuration.
Xue, Ning; Martinez, Ignacio Delgado; Sun, Jianhai; Cheng, Yuhua; Liu, Chunxiu
2018-07-30
Vagus nerve stimulation is an emerging bioelectronic medicine to modulate cardiac function, as the nerve provides parasympathetic innervation to the heart. In this study, we developed a polyimide based 2D cuff electrode to wrap around on the vagus nerve. Thanks to the tiny size and bendable protruding structure of the contact tips of the device, the electrode sites are able to flexibly bend to touch the nerve, selectively record and stimulate the vagus nerve. Gold, platinum and platinum black materials were chosen to compose the electrodes for nerve stimulation and recording, respectively. Since the platinum black has ~30 times larger charge delivery capacity (CDC) than gold, Pt black electrode is used for nerve stimulation. The electrochemical impedance spectroscopy and cyclic voltammetry measurement of the three materials were conducted in vitro, revealing the results of 405 kΩ, 41 kΩ, 10.5 kΩ, @1 kHz and 0.81 mC/cm 2 , 4.26 mC/cm 2 , 25.5 mC/cm 2 , respectively (n = 3). The cuff electrodes were implanted into the right-sided vagus nerve of rats for in vivo experiment. Biphasic current configuration was implemented for nerve stimulation with frequency of 10 Hz, pulse during of 300 μs and various currents stimulus. The result shows the heart beat frequency drops up to 36% during the stimulation and was able to return the regular frequency as stimulation was removed. Subsequently, the vagus nerve signals were recorded with the four channel cuff electrodes. The magnitude of the compound nerve action potentials (CNAPs) is ~10 μV and the signal to noise ratio (SNR) is ~20. Copyright © 2018 Elsevier B.V. All rights reserved.
Clasen, Stephan; Schmidt, Diethard; Boss, Andreas; Dietz, Klaus; Kröber, Stefan M; Claussen, Claus D; Pereira, Philippe L
2006-03-01
To evaluate the size and geometry of thermally induced coagulation by using multipolar radiofrequency (RF) ablation and to determine a mathematic model to predict coagulation volume. Multipolar RF ablations (n = 80) were performed in ex vivo bovine livers by using three internally cooled bipolar applicators with two electrodes on the same shaft. Applicators were placed in a triangular array (spacing, 2-5 cm) and were activated in multipolar mode (power output, 75-225 W). The size and geometry of the coagulation zone, together with ablation time, were assessed. Mathematic functions were fitted, and the goodness of fit was assessed by using r(2). Coagulation volume, short-axis diameter, and ablation time were dependent on power output and applicator distance. The maximum zone of coagulation (volume, 324 cm(3); short-axis diameter, 8.4 cm; ablation time, 193 min) was induced with a power output of 75 W at an applicator distance of 5 cm. Coagulation volume and ablation time decreased as power output increased. Power outputs of 100-125 W at applicator distances of 2-4 cm led to a reasonable compromise between coagulation volume and ablation time. At 2 cm (100 W), coagulation volume, short-axis diameter, and ablation time were 66 cm(3), 4.5 cm, and 19 min, respectively; at 3 cm (100 W), 90 cm(3), 5.2 cm, and 22 min, respectively; at 4 cm (100 W), 132 cm(3), 6.1 cm, and 27 min, respectively; at 2 cm (125 W), 56 cm(3), 4.2 cm, and 9 min, respectively; at 3 cm (125 W), 73 cm(3), 4.9 cm, and 12 min, respectively; and at 4 cm (125 W), 103 cm(3), 5.5 cm, and 16 min, respectively. At applicator distances of 4 cm (>125 W) and 5 cm (>100 W), the zones of coagulation were not confluent. Coagulation volume (r(2) = 0.80) and RF ablation time (r(2) = 0.93) were determined by using the mathematic model. Multipolar RF ablation with three bipolar applicators may produce large volumes of confluent coagulation ex vivo. A compromise is necessary between prolonged RF ablations at lower power outputs, which produce larger volumes of coagulation, and faster RF ablations at higher power outputs, which produce smaller volumes of coagulation. Copyright RSNA, 2006.
Shon, Ahnsei; Chu, Jun-Uk; Jung, Jiuk; Kim, Hyungmin; Youn, Inchan
2017-12-21
Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.
Shon, Ahnsei; Chu, Jun-Uk; Jung, Jiuk; Youn, Inchan
2017-01-01
Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time. PMID:29267230
Bioactive nitric oxide concentration does not increase during reactive hyperemia in human skin.
Zhao, J L; Pergola, P E; Roman, L J; Kellogg, D L
2004-02-01
This study examined whether nitric oxide (NO) is involved in the cutaneous response to reactive hyperemia (RH) in the human forearm. We enrolled seven healthy volunteers. NO concentrations were monitored using a NO selective amperometric electrode (ISO-NOP200, World Precision Instruments) inserted into the skin of the forearm. Laser-Doppler flowmetry (Moor Instruments) was used for monitoring skin blood flow (SkBF) at the same site. SkBF and NO levels were monitored and recorded continuously throughout the experiment. An intradermal microdialysis probe was inserted adjacent to the NO electrode for drug delivery. Data collection began 140 min after the NO electrodes and microdialysis probes were inserted. RH was achieved by the inflation of a blood pressure cuff to 25 mmHg above systolic pressure for 7 min after which the pressure in the cuff was abruptly released. Acetylcholine (ACh) was given by microdialysis probe at the end of RH study to verify the ability of the electrode system to detect changes in the NO concentration. SkBF and NO data before RH and immediately, 2, 5, 7, and 10 min after cuff deflation were used for analysis. SkBF increased immediately after release of the occlusion (P < 0.0001) and remained elevated for 2 min. No significant NO changes occurred with the increases in LDF. ACh induced increases in both SkBF and NO (P < 0.000 and P < 0.037, respectively). We conclude that RH increases SkBF by mechanisms that do not require a measurable increase in NO concentrations.
Ritz, Joerg-Peter; Lehmann, Kai S; Reissfelder, Christoph; Albrecht, Thomas; Frericks, Bernd; Zurbuchen, Urte; Buhr, Heinz J
2006-01-01
Radiofrequency ablation (RFA) is a promising method for local treatment of liver malignancies. Currently available systems for radiofrequency ablation use monopolar current, which carries the risk of uncontrolled electrical current paths, collateral damages and limited effectiveness. To overcome this problem, we used a newly developed internally cooled bipolar application system in patients with irresectable liver metastases undergoing laparotomy. The aim of this study was to clinically evaluate the safety, feasibility and effectiveness of this new system with a novel multipolar application concept. Patients with a maximum of five liver metastases having a maximum diameter of 5 cm underwent laparotomy and abdominal exploration to control resectability. In cases of irresectability, RFA with the newly developed bipolar application system was performed. Treatment was carried out under ultrasound guidance. Depending on tumour size, shape and location, up to three applicators were simultaneously inserted in or closely around the tumour, never exceeding a maximum probe distance of 3 cm. In the multipolar ablation concept, the current runs alternating between all possible pairs of consecutively activated electrodes with up to 15 possible electrode combinations. Post-operative follow-up was evaluated by CT or MRI controls 24-48 h after RFA and every 3 months. In a total of six patients (four male, two female; 61-68 years), ten metastases (1.0-5.5 cm) were treated with a total of 14 RF applications. In four metastases three probes were used, and in another four and two metastases, two and one probes were used, respectively. During a mean ablation time of 18.8 min (10-31), a mean energy of 48.8 kJ (12-116) for each metastases was applied. No procedure-related complications occurred. The patients were released from the hospital between 7 and 12 days post-intervention (median 9 days). The post-interventional control showed complete tumour ablation in all cases. Bipolar radiofrequency using the novel multipolar ablation concept permits a safe and effective therapy for the induction of large volumes of coagulation in the local treatment of liver metastases.
Triantis, Iasonas F; Demosthenous, Andreas
2008-06-01
Ideally, interference in neural measurements due to signals from nearby muscles can be completely eliminated with the use of tripolar cuffs, in combination with appropriate amplifier configurations, such as the quasi-tripole (QT) and the true-tripole (TT). The operation of these amplifiers, is based on the theoretical property of the nerve cuff to produce a linear relationship of potential versus distance along its length, internally, when external potentials appear between its ends. Thus, in principle, electroneurogram (ENG) recordings from an ideal tripolar cuff would be free from electromyogram (EMG) interference generated by nearby muscles. However, in practice the cuff exhibits non-ideal behaviour leading to "cuff imbalance". The main focus of this paper is to investigate the causes of cuff imbalance, to demonstrate that it should be incorporated as a main parameter in the theoretical ENG-recording cuff electrode model. In addition to cuff asymmetry and tissue growth, the proximity of the interference source to the cuff is shown to result in cuff imbalance. The influence of proximity imbalance on the performance of the QT and TT amplifiers is also considered. Proximity imbalance is studied using bioelectric field simulations and saline-bath experiments. Variation is observed with both distance (40 mm and 70 mm was examined) and orientation (0-180 degrees), with the latter causing a more severe effect especially when the source dipole and the cuff are vertical to each other. The simulations and measurements are in close agreement. Tissue growth imbalance and asymmetry imbalance are also investigated in vitro. Finally, the signal-to-interference ratio (SIR; ENG/EMG) of the QT and TT amplifiers is examined in the presence of cuff imbalance. It is shown that proximity imbalance results in their SIR to peak only at certain cuff orientation values. This important finding offers an insight as to why in practice ENG recordings using these amplifiers have been widely reported to be degraded by EMG interference.
Multipolar hepatic radiofrequency ablation using up to six applicators: preliminary results.
Bruners, P; Schmitz-Rode, T; Günther, R W; Mahnken, A
2008-03-01
To evaluate the clinical feasibility and safety of hepatic radiofrequency (RF) ablation using a multipolar RF system permitting the simultaneous use of up to six electrodes. Ten patients (3 female, 7 male, mean age 61) suffering from 29 hepatic metastases (range: 1 - 5) of different tumors were treated with a modified multipolar RF system (CelonLab Power, Celon Medical Instruments, Teltow, Germany) operating four to six needle-shaped internally cooled RF applicators. The procedure duration, applied energy and generator output were recorded during the intervention. The treatment result and procedure-related complications were analyzed. The achieved coagulation volume was calculated on the basis of contrast-enhanced CT scans 24 hours after RF ablation. Complete tumor ablation was achieved in all cases as determined by the post-interventional lack of contrast enhancement in the target region using four applicators in five patients, five applicators in one patient and six applicators in four patients. A mean energy deposition of 353.9 +/- 176.2 kJ resulted in a mean coagulation volume of 115.9 +/- 79.5 cm (3). The mean procedure duration was 74.9 +/- 21.2 minutes. Four patients showed an intraabdominal hemorrhage which necessitated further interventional treatment (embolization; percutaneous histoacryl injection) in two patients. Multipolar RF ablation of hepatic metastasis with up to six applicators was clinically feasible. In our patient population it was associated with an increased risk of intraabdominal bleeding probably due to the multiple punctures associated with the use of multiple applicators.
Evaluation of focused multipolar stimulation for cochlear implants in long-term deafened cats
NASA Astrophysics Data System (ADS)
George, Shefin S.; Wise, Andrew K.; Fallon, James B.; Shepherd, Robert K.
2015-06-01
Objective. Focused multipolar (FMP) stimulation has been shown to produce restricted neural activation using intracochlear stimulation in animals with a normal population of spiral ganglion neurons (SGNs). However, in a clinical setting, the widespread loss of SGNs and peripheral fibres following deafness is expected to influence the effectiveness of FMP. Approach. We compared the efficacy of FMP stimulation to both monopolar (MP) and tripolar (TP) stimulation in long-term deafened cat cochleae (n = 8). Unlike our previous study, these cochleae contained <10% of the normal SGN population adjacent to the electrode array. We also evaluated the effect of electrode position on stimulation modes by using either modiolar facing or lateral wall facing half-band electrodes. The spread of neural activity across the inferior colliculus, a major nucleus within the central auditory pathway, was used as a measure of spatial selectivity. Main results. In cochleae with significant SGN degeneration, we observed that FMP and TP stimulation resulted in greater spatial selectivity than MP stimulation (p < 0.001). However, thresholds were significantly higher for FMP and TP stimulation compared to MP stimulation (p < 0.001). No difference between FMP and TP stimulation was found in any measures. The high threshold levels for FMP stimulation was significantly reduced without compromising spatial selectivity by varying the degree of current focusing (referred as ‘partial-FMP’ stimulation). Spatial selectivity of all stimulation modes was unaffected by the electrode position. Finally, spatial selectivity in long-term deafened cochleae was significantly less than that of cochleae with normal SGN population (George S S et al 2014 J. Neural Eng. 11 065003). Significance. The present results indicate that the greater spatial selectivity of FMP and TP stimulation over MP stimulation is maintained in cochleae with significant neural degeneration and is not adversely affected by electrode position. The greater spatial selectivity of FMP and TP stimulation would be expected to result in improved clinical performance.
2013-01-01
Background Cuff electrodes have been widely used chronically in different clinical applications. This neural interface has been dominantly used for nerve stimulation while interfering noise is the major issue when employed for recording purposes. Advancements have been made in rejecting extra-neural interference by using continuous ring contacts in tripolar topologies. Ring contacts provide an average of the neural activity, and thus reduce the information retrieved. Splitting these contacts into smaller recording areas could potentially increase the information content. In this study, we investigate the impact of such discretization on the Signal-to-Noise Ratio (SNR). The effect of contacts positioning and an additional short circuited pair of electrodes were also addressed. Methods Different recording configurations using ring, dot, and a mixed of both contacts were studied in vitro in a frog model. An interfering signal was induced in the medium to simulate myoelectric noise. The experimental setup was design in such a way that the only difference between recordings was the configuration used. The inter-session experimental differences were taken care of by a common configuration that allowed normalization between electrode designs. Results It was found that splitting all contacts into small recording areas had negative effects on noise rejection. However, if this is only applied to the central contact creating a mixed tripole configuration, a considerable and statistically significant improvement was observed. Moreover, the signal to noise ratio was equal or larger than what can be achieved with the best known configuration, namely the short circuited tripole. This suggests that for recording purposes, any tripole topology would benefit from splitting the central contact into one or more discrete contacts. Conclusions Our results showed that a mixed tripole configuration performs better than the configuration including only ring contacts. Therefore, splitting the central ring contact of a cuff electrode into a number of dot contacts not only provides additional information but also an improved SNR. In addition, the effect of an additional pair of short circuited electrodes and the “end effect” observed with the presented method are in line with previous findings by other authors. PMID:23433089
Haugland, M; Lickel, A; Haase, J; Sinkjaer, T
1999-06-01
A tetraplegic volunteer was implanted with percutaneous intramuscular electrodes in hand and forearm muscles. Furthermore, a sensory nerve cuff electrode was implanted on the volar digital nerve to the radial side of the index finger branching off the median nerve. In laboratory experiments a stimulation system was used to produce a lateral grasp (key grip) while the neural activity was recorded with the cuff electrode. The nerve signal contained information that could be used to detect the occurrence of slips and further to increase stimulation intensity to the thumb flexor/adductor muscles to stop the slip. Thereby the system provided a grasp that could catch an object if it started to slip due to, e.g., decreasing muscle force or changes in load forces tangential to the surface of the object. This method enabled an automatic adjustment of the stimulation intensity to the lowest possible level without loosing the grip and without any prior knowledge about the strength of the muscles and the weight and surface texture of the object.
Gierthmuehlen, Mortimer; Freiman, Thomas M; Haastert-Talini, Kirsten; Mueller, Alexandra; Kaminsky, Jan; Stieglitz, Thomas; Plachta, Dennis T T
2013-01-01
The development of neural cuff-electrodes requires several in vivo studies and revisions of the electrode design before the electrode is completely adapted to its target nerve. It is therefore favorable to simulate many of the steps involved in this process to reduce costs and animal testing. As the restoration of motor function is one of the most interesting applications of cuff-electrodes, the position and trajectories of myelinated fibers in the simulated nerve are important. In this paper, we investigate a method for building a precise neuroanatomical model of myelinated fibers in a peripheral nerve based on images obtained using high-resolution light microscopy. This anatomical model describes the first aim of our "Virtual workbench" project to establish a method for creating realistic neural simulation models based on image datasets. The imaging, processing, segmentation and technical limitations are described, and the steps involved in the transition into a simulation model are presented. The results showed that the position and trajectories of the myelinated axons were traced and virtualized using our technique, and small nerves could be reliably modeled based on of light microscopy images using low-cost OpenSource software and standard hardware. The anatomical model will be released to the scientific community.
Gierthmuehlen, Mortimer; Freiman, Thomas M.; Haastert-Talini, Kirsten; Mueller, Alexandra; Kaminsky, Jan; Stieglitz, Thomas; Plachta, Dennis T. T.
2013-01-01
The development of neural cuff-electrodes requires several in vivo studies and revisions of the electrode design before the electrode is completely adapted to its target nerve. It is therefore favorable to simulate many of the steps involved in this process to reduce costs and animal testing. As the restoration of motor function is one of the most interesting applications of cuff-electrodes, the position and trajectories of myelinated fibers in the simulated nerve are important. In this paper, we investigate a method for building a precise neuroanatomical model of myelinated fibers in a peripheral nerve based on images obtained using high-resolution light microscopy. This anatomical model describes the first aim of our “Virtual workbench” project to establish a method for creating realistic neural simulation models based on image datasets. The imaging, processing, segmentation and technical limitations are described, and the steps involved in the transition into a simulation model are presented. The results showed that the position and trajectories of the myelinated axons were traced and virtualized using our technique, and small nerves could be reliably modeled based on of light microscopy images using low-cost OpenSource software and standard hardware. The anatomical model will be released to the scientific community. PMID:23785485
Makeyev, Oleksandr; Besio, Walter G.
2016-01-01
Noninvasive concentric ring electrodes are a promising alternative to conventional disc electrodes. Currently, the superiority of tripolar concentric ring electrodes over disc electrodes, in particular, in accuracy of Laplacian estimation, has been demonstrated in a range of applications. In our recent work, we have shown that accuracy of Laplacian estimation can be improved with multipolar concentric ring electrodes using a general approach to estimation of the Laplacian for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method for n ≥ 2. This paper takes the next step toward further improving the Laplacian estimate by proposing novel variable inter-ring distances concentric ring electrodes. Derived using a modified (4n + 1)-point method, linearly increasing and decreasing inter-ring distances tripolar (n = 2) and quadripolar (n = 3) electrode configurations are compared to their constant inter-ring distances counterparts. Finite element method modeling and analytic results are consistent and suggest that increasing inter-ring distances electrode configurations may decrease the truncation error resulting in more accurate Laplacian estimates compared to respective constant inter-ring distances configurations. For currently used tripolar electrode configuration, the truncation error may be decreased more than two-fold, while for the quadripolar configuration more than a six-fold decrease is expected. PMID:27294933
Makeyev, Oleksandr; Besio, Walter G
2016-06-10
Noninvasive concentric ring electrodes are a promising alternative to conventional disc electrodes. Currently, the superiority of tripolar concentric ring electrodes over disc electrodes, in particular, in accuracy of Laplacian estimation, has been demonstrated in a range of applications. In our recent work, we have shown that accuracy of Laplacian estimation can be improved with multipolar concentric ring electrodes using a general approach to estimation of the Laplacian for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method for n ≥ 2. This paper takes the next step toward further improving the Laplacian estimate by proposing novel variable inter-ring distances concentric ring electrodes. Derived using a modified (4n + 1)-point method, linearly increasing and decreasing inter-ring distances tripolar (n = 2) and quadripolar (n = 3) electrode configurations are compared to their constant inter-ring distances counterparts. Finite element method modeling and analytic results are consistent and suggest that increasing inter-ring distances electrode configurations may decrease the truncation error resulting in more accurate Laplacian estimates compared to respective constant inter-ring distances configurations. For currently used tripolar electrode configuration, the truncation error may be decreased more than two-fold, while for the quadripolar configuration more than a six-fold decrease is expected.
Makeyev, Oleksandr; Besio, Walter G
2016-08-01
Noninvasive concentric ring electrodes are a promising alternative to conventional disc electrodes. Currently, superiority of tripolar concentric ring electrodes over disc electrodes, in particular, in accuracy of Laplacian estimation has been demonstrated in a range of applications. In our recent work we have shown that accuracy of Laplacian estimation can be improved with multipolar concentric ring electrodes using a general approach to estimation of the Laplacian for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method for n ≥ 2. This paper takes the next step toward further improving the Laplacian estimate by proposing novel variable inter-ring distances concentric ring electrodes. Derived using a modified (4n + 1)-point method, linearly increasing and decreasing inter-ring distances tripolar (n = 2) and quadripolar (n = 3) electrode configurations are compared to their constant inter-ring distances counterparts using finite element method modeling. Obtained results suggest that increasing inter-ring distances electrode configurations may decrease the estimation error resulting in more accurate Laplacian estimates compared to respective constant inter-ring distances configurations. For currently used tripolar electrode configuration the estimation error may be decreased more than two-fold while for the quadripolar configuration more than six-fold decrease is expected.
Makeyev, Oleksandr; Besio, Walter G
2016-08-01
Noninvasive concentric ring electrodes are a promising alternative to conventional disc electrodes. Currently, superiority of tripolar concentric ring electrodes over disc electrodes, in particular, in accuracy of Laplacian estimation has been demonstrated in a range of applications. In our recent work we have shown that accuracy of Laplacian estimation can be improved with multipolar concentric ring electrodes using a general approach to estimation of the Laplacian for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method for n ≥ 2. This paper takes the next step toward further improving the Laplacian estimate by proposing novel variable inter-ring distances concentric ring electrodes. Derived using a modified (4n + 1)-point method, linearly increasing inter-ring distances tripolar (n = 2) and quadripolar (n = 3) electrode configurations are analytically compared to their constant inter-ring distances counterparts using coefficients of the Taylor series truncation terms. Obtained results suggest that increasing inter-ring distances electrode configurations may decrease the truncation error of the Laplacian estimation resulting in more accurate Laplacian estimates compared to respective constant inter-ring distances configurations. For currently used tripolar electrode configuration the truncation error may be decreased more than two-fold while for the quadripolar more than seven-fold decrease is expected.
Rathi, Sangeeta; Taylor, Nicholas F; Soo, Brendan; Green, Rodney A
2018-03-02
To determine whether patients with symptomatic rotator cuff pathology had more glenohumeral joint translation and different patterns of rotator cuff muscle activity compared to controls. Repeated measurements of glenohumeral translation and muscle activity in two positions and six testing conditions in two groups. Twenty participants with a symptomatic and diagnosed rotator cuff tear and 20 age, and gender matched controls were included. Neuromuscular activity was tested by inserting intramuscular electrodes in the rotator cuff muscles. Anterior and posterior glenohumeral translations were measured using real time ultrasound in testing conditions (with and without translation force, with and without isometric internal and external rotation), in two positions (shoulder neutral, 90° of abduction) and two force directions (anterior, posterior). Symptomatic pathology group demonstrated increased passive glenohumeral translation with posterior translation force (p<0.05). Overall, rotator cuff muscle contraction in the pathology group limited joint translation in a similar manner to the control group, but they did not show the normal direction specific pattern in the neutral posterior position (p<0.03). The pathology group demonstrated reduced EMG activity in the upper infraspinatus muscle relative to the reference position (p<0.02) with anterior translation force and in the supraspinatus (p<0.05) muscle with anterior and posterior translation force in the abducted position. Symptomatic pathology resulted in increased passive glenohumeral joint translation. Although there were some reductions in muscle activity with injury, their rotator cuff still controlled glenohumeral translation. These results highlight the need to consider joint translation in the assessment and management of patients with rotator cuff injury. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Rathi, Sangeeta; Taylor, Nicholas F; Green, Rodney A
2016-12-08
The proposed stabilizing mechanism of rotator cuff muscles is to limit excessive humeral head translation. However, an accurate measurement of glenohumeral joint translation in vivo has been challenging. We aimed to measure the effect of rotator cuff muscle contraction on glenohumeral joint translation using real time ultrasound (RTUS) and electromyography. Twenty healthy adults with no history of shoulder pathology were recruited. Six intramuscular electrodes were inserted in the rotator cuff muscles (supraspinatus, upper and lower infraspinatus, teres minor, upper and lower subscapularis). Anterior and posterior glenohumeral translations were measured in testing conditions (with and without translation force, with and without isometric internal and external rotation), in two positions (shoulder neutral, abduction) and views (anterior, posterior). There was reduced glenohumeral translation with rotator cuff muscle contraction in the neutral anterior (F 2,38 =17.8, p<0.01), neutral posterior (F 1.6,31.0 =44.3, p<0.01) and abducted posterior (F 1.5,28.8 =5.2, p<0.02) positions. There were also differences between the amount of translation limited by anterior and posterior rotator cuff muscles in response to anterior and posterior translation forces (p<0.05), indicating that their activity was, to a certain extent, direction specific. For example, in both neutral and abducted positions, contraction of the posterior rotator cuff muscles, infraspinatus and teres minor, appeared to tether anterior translation of the humeral head. Our results confirm that the rotator cuff functions as a stabilizer of the glenohumeral joint by limiting humeral head translation and this is likely to be in a direction-specific manner. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ultra-low noise miniaturized neural amplifier with hardware averaging.
Dweiri, Yazan M; Eggers, Thomas; McCallum, Grant; Durand, Dominique M
2015-08-01
Peripheral nerves carry neural signals that could be used to control hybrid bionic systems. Cuff electrodes provide a robust and stable interface but the recorded signal amplitude is small (<3 μVrms 700 Hz-7 kHz), thereby requiring a baseline noise of less than 1 μVrms for a useful signal-to-noise ratio (SNR). Flat interface nerve electrode (FINE) contacts alone generate thermal noise of at least 0.5 μVrms therefore the amplifier should add as little noise as possible. Since mainstream neural amplifiers have a baseline noise of 2 μVrms or higher, novel designs are required. Here we apply the concept of hardware averaging to nerve recordings obtained with cuff electrodes. An optimization procedure is developed to minimize noise and power simultaneously. The novel design was based on existing neural amplifiers (Intan Technologies, LLC) and is validated with signals obtained from the FINE in chronic dog experiments. We showed that hardware averaging leads to a reduction in the total recording noise by a factor of 1/√N or less depending on the source resistance. Chronic recording of physiological activity with FINE using the presented design showed significant improvement on the recorded baseline noise with at least two parallel operation transconductance amplifiers leading to a 46.1% reduction at N = 8. The functionality of these recordings was quantified by the SNR improvement and shown to be significant for N = 3 or more. The present design was shown to be capable of generating <1.5 μVrms total recording baseline noise when connected to a FINE placed on the sciatic nerve of an awake animal. An algorithm was introduced to find the value of N that can minimize both the power consumption and the noise in order to design a miniaturized ultralow-noise neural amplifier. These results demonstrate the efficacy of hardware averaging on noise improvement for neural recording with cuff electrodes, and can accommodate the presence of high source impedances that are associated with the miniaturized contacts and the high channel count in electrode arrays. This technique can be adopted for other applications where miniaturized and implantable multichannel acquisition systems with ultra-low noise and low power are required.
Evaluation of focused multipolar stimulation for cochlear implants: a preclinical safety study
NASA Astrophysics Data System (ADS)
Shepherd, Robert K.; Wise, Andrew K.; Enke, Ya Lang; Carter, Paul M.; Fallon, James B.
2017-08-01
Objective. Cochlear implants (CIs) have a limited number of independent stimulation channels due to the highly conductive nature of the fluid-filled cochlea. Attempts to develop highly focused stimulation to improve speech perception in CI users includes the use of simultaneous stimulation via multiple current sources. Focused multipolar (FMP) stimulation is an example of this approach and has been shown to reduce interaction between stimulating channels. However, compared with conventional biphasic current pulses generated from a single current source, FMP is a complex stimulus that includes extended periods of stimulation before charge recovery is achieved, raising questions on whether chronic stimulation with this strategy is safe. The present study evaluated the long-term safety of intracochlear stimulation using FMP in a preclinical animal model of profound deafness. Approach. Six cats were bilaterally implanted with scala tympani electrode arrays two months after deafening, and received continuous unilateral FMP stimulation at levels that evoked a behavioural response for periods of up to 182 d. Electrode impedance, electrically-evoked compound action potentials (ECAPs) and auditory brainstem responses (EABRs) were monitored periodically over the course of the stimulation program from both the stimulated and contralateral control cochleae. On completion of the stimulation program cochleae were examined histologically and the electrode arrays were evaluated for evidence of platinum (Pt) corrosion. Main results. There was no significant difference in electrode impedance between control and chronically stimulated electrodes following long-term FMP stimulation. Moreover, there was no significant difference between ECAP and EABR thresholds evoked from control or stimulated cochleae at either the onset of stimulation or at completion of the stimulation program. Chronic FMP stimulation had no effect on spiral ganglion neuron (SGN) survival when compared with unstimulated control cochleae. Long-term implantation typically evoked a mild foreign body reaction proximal to the electrode array; however stimulated cochleae exhibited a small but statistically significant increase in the tissue response. Finally, there was no evidence of Pt corrosion following long-term FMP stimulation; stimulated electrodes exhibited the same surface features as the unstimulated control electrodes. Significance. Chronic intracochlear FMP stimulation at levels used in the present study did not adversely affect electrically-evoked neural thresholds or SGN survival but evoked a small, benign increase in inflammatory response compared to control ears. Moreover chronic FMP stimulation does not affect the surface of Pt electrodes at suprathreshold stimulus levels. These findings support the safe clinical application of an FMP stimulation strategy.
Electrophysiological channel interactions using focused multipolar stimulation for cochlear implants
NASA Astrophysics Data System (ADS)
George, Shefin S.; Shivdasani, Mohit N.; Wise, Andrew K.; Shepherd, Robert K.; Fallon, James B.
2015-12-01
Objective. Speech intelligibility with existing multichannel cochlear implants (CIs) is thought to be limited by poor spatial selectivity and interactions between CI channels caused by overlapping activation with monopolar (MP) stimulation. Our previous studies have shown that focused multipolar (FMP) and tripolar (TP) stimulation produce more restricted neural activation in the inferior colliculus (IC), compared to MP stimulation. Approach. This study explored interactions in the IC produced by simultaneous stimulation of two CI channels. We recorded multi-unit neural activity in the IC of anaesthetized cats with normal and severely degenerated spiral ganglion neuron populations in response to FMP, TP and MP stimulation from a 14 channel CI. Stimuli were applied to a ‘fixed’ CI channel, chosen toward the middle of the cochlear electrode array, and the effects of simultaneously stimulating a more apical ‘test’ CI channel were measured as a function of spatial separation between the two stimulation channels and stimulus level of the fixed channel. Channel interactions were quantified by changes in neural responses and IC threshold (i.e., threshold shift) elicited by simultaneous stimulation of two CI channels, compared to stimulation of the test channel alone. Main results. Channel interactions were significantly lower for FMP and TP than for MP stimulation (p < 0.001), whereas no significant difference was observed between FMP and TP stimulation. With MP stimulation, threshold shifts increased with decreased inter-electrode spacing and increased stimulus levels of the fixed channel. For FMP and TP stimulation, channel interactions were found to be similar for different inter-electrode spacing and stimulus levels of the fixed channel. Significance. The present study demonstrates how the degree of channel interactions in a CI can be controlled using stimulation configurations such as FMP and TP; such knowledge is essential in enhancing CI function in complex acoustic environments.
Glove perforations and blood contact associated with manipulation of the fetal scalp electrode.
Rhoton-Vlasak, A; Duff, P
1993-02-01
To assess prospectively the frequency of glove injury associated with insertion of the fetal scalp electrode and subsequent examination of the cervix with the electrode in place. Over a 7-month period, sterile gloves were collected after use for insertion of the fetal scalp electrode or cervical examination with the electrode in place. Attendants indicated their level of training, time, date and purpose of glove use, and cervical examination. They also noted whether they were aware of a glove perforation or observed blood, amniotic fluid, or genital tract secretions on their hand. Glove patency was assessed by filling the glove with water to 1.5-2.0 times its normal volume and observing for leaks. One hundred unused gloves were tested for patency and served as controls. Five hundred one gloves were evaluated, of which 13 (2.6%, 95% confidence interval [Cl] 1-4%) had perforations. Seven of 277 gloves (2.5%) used only for examinations had perforations, compared with six of 244 (2.5%) used only for insertion of the electrode. Two percent (95% CI 0-5%) of the unused control gloves had perforations. These observed differences were not statistically significant. Nineteen attendants (3.8%, 95% CI 2.1-5.5%) noted blood or genital tract secretions on their hand after insertion of the electrode (N = 4) or subsequent cervical examination (N = 15). Only one point of contract resulted from a glove perforation; the other 18 were on the wrist and apparently resulted from leakage of fluid around the open cuff of the glove. The risk of glove perforation during insertion of the fetal scalp electrode or subsequent cervical examination is low if proper technique is observed. Blood or fluid contact is more likely to result from leakage of fluid around the open cuff of the glove during a vaginal examination.
Nerve monitoring-guided selective hypoglossal nerve stimulation in obstructive sleep apnea patients.
Heiser, Clemens; Hofauer, Benedikt; Lozier, Luke; Woodson, B Tucker; Stark, Thomas
2016-12-01
Selective stimulation of the upper airway is a new therapy for obstructive sleep apnea. The aim of the study was to determine if a selective nerve integrity monitoring (NIM) system could aid in precise placement of the cuff electrode in selective upper-airway stimulation. Single-center, prospective clinical trial. Twenty patients who received a selective upper-airway stimulation system (Inspire Medical Systems, Maple Grove, MN) were implanted by using a NIM system. The tongue motions were recorded during surgery and 2 months postoperatively from the transoral view and by transnasal endoscopy. All patients exhibited consistent protrusion at tongue front and tongue base. The nerve monitoring system helped to place the cuff electrode around the protrusion and stiffening branches, while excluding the retractor branches of the hypoglossal nerve. This report demonstrated a novel use of a NIM system to identify the functional separation between inclusion and exclusion branches of the hypoglossal nerve for implantation of a selective upper-airway stimulation system. 4. Laryngoscope, 126:2852-2858, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
The design of and chronic tissue response to a composite nerve electrode with patterned stiffness.
Freeberg, M J; Stone, M A; Triolo, R J; Tyler, D J
2017-06-01
As neural interfaces demonstrate success in chronic applications, a novel class of reshaping electrodes with patterned regions of stiffness will enable application to a widening range of anatomical locations. Patterning stiff regions and flexible regions of the electrode enables nerve reshaping while accommodating anatomical constraints of various implant locations ranging from peripheral nerves to spinal and autonomic plexi. Introduced is a new composite electrode enabling patterning of regions of various electrode mechanical properties. The initial demonstration of the composite's capability is the composite flat interface nerve electrode (C-FINE). The C-FINE is constructed from a sandwich of patterned PEEK within layers of pliable silicone. The shape of the PEEK provides a desired pattern of stiffness: stiff across the width of the nerve to reshape the nerve, but flexible along its length to allow for bending with the nerve. This is particularly important in anatomical locations near joints or organs, and in constrained compartments. We tested pressure and volume design constraints in vitro to verify that the C-FINE can attain a safe cuff-to-nerve ratio (CNR) without impeding intraneural blood flow. We measured nerve function as well as nerve and axonal morphology following 3 month implantation of the C-FINE without wires on feline peripheral nerves in anatomically constrained areas near mobile joints and major blood vessels in both the hind and fore limbs. In vitro inflation tests showed effective CNRs (1.93 ± 0.06) that exceeded the industry safety standard of 1.5 at an internal pressure of 20 mmHg. This is less than the 30 mmHg shown to induce loss of conduction or compromise blood flow. Implanted cats showed no changes in physiology or electrophysiology. Behavioral signs were normal suggesting healthy nerves. Motor nerve conduction velocity and compound motor action potential did not change significantly between implant and explant (p > 0.15 for all measures). Axonal density and myelin sheath thickness was not significantly different within the electrode compared to sections greater than 2 cm proximal to implanted cuffs (p > 0.14 for all measures). We present the design and verification of a novel nerve cuff electrode, the C-FINE. Laminar manufacturing processes allow C-FINE stiffness to be configured for specific applications. Here, the central region in the configuration tested is stiff to reshape or conform to the target nerve, while edges are highly flexible to bend along its length. The C-FINE occupies less volume than other NCEs, making it suitable for implantation in highly mobile locations near joints. Design constraints during simulated transient swelling were verified in vitro. Maintenance of nerve health in various challenging anatomical locations (sciatic and median/ulnar nerves) was verified in a chronic feline model in vivo.
The design of and chronic tissue response to a composite nerve electrode with patterned stiffness
NASA Astrophysics Data System (ADS)
Freeberg, M. J.; Stone, M. A.; Triolo, R. J.; Tyler, D. J.
2017-06-01
Objective. As neural interfaces demonstrate success in chronic applications, a novel class of reshaping electrodes with patterned regions of stiffness will enable application to a widening range of anatomical locations. Patterning stiff regions and flexible regions of the electrode enables nerve reshaping while accommodating anatomical constraints of various implant locations ranging from peripheral nerves to spinal and autonomic plexi. Approach. Introduced is a new composite electrode enabling patterning of regions of various electrode mechanical properties. The initial demonstration of the composite’s capability is the composite flat interface nerve electrode (C-FINE). The C-FINE is constructed from a sandwich of patterned PEEK within layers of pliable silicone. The shape of the PEEK provides a desired pattern of stiffness: stiff across the width of the nerve to reshape the nerve, but flexible along its length to allow for bending with the nerve. This is particularly important in anatomical locations near joints or organs, and in constrained compartments. We tested pressure and volume design constraints in vitro to verify that the C-FINE can attain a safe cuff-to-nerve ratio (CNR) without impeding intraneural blood flow. We measured nerve function as well as nerve and axonal morphology following 3 month implantation of the C-FINE without wires on feline peripheral nerves in anatomically constrained areas near mobile joints and major blood vessels in both the hind and fore limbs. Main Results. In vitro inflation tests showed effective CNRs (1.93 ± 0.06) that exceeded the industry safety standard of 1.5 at an internal pressure of 20 mmHg. This is less than the 30 mmHg shown to induce loss of conduction or compromise blood flow. Implanted cats showed no changes in physiology or electrophysiology. Behavioral signs were normal suggesting healthy nerves. Motor nerve conduction velocity and compound motor action potential did not change significantly between implant and explant (p > 0.15 for all measures). Axonal density and myelin sheath thickness was not significantly different within the electrode compared to sections greater than 2 cm proximal to implanted cuffs (p > 0.14 for all measures). Significance. We present the design and verification of a novel nerve cuff electrode, the C-FINE. Laminar manufacturing processes allow C-FINE stiffness to be configured for specific applications. Here, the central region in the configuration tested is stiff to reshape or conform to the target nerve, while edges are highly flexible to bend along its length. The C-FINE occupies less volume than other NCEs, making it suitable for implantation in highly mobile locations near joints. Design constraints during simulated transient swelling were verified in vitro. Maintenance of nerve health in various challenging anatomical locations (sciatic and median/ulnar nerves) was verified in a chronic feline model in vivo.
Mizutani, Ken-Ichi
2018-01-01
Neurogenesis encompasses an entire set of events that leads to the generation of newborn neurons from neural stem cells and more committed progenitor cells, including cell division, the production of migratory precursors and their progeny, differentiation and integration into circuits. In particular, the precise control of neuronal migration and morphological changes is essential for the development of the neocortex. Postmitotic cells within the intermediate zone have been found to transiently assume a characteristic "multipolar" morphology, after which a multipolar-to-bipolar transition occurs before the cells enter the cortical plate; however, the importance of this multipolar phase in the establishment of mature cortical cytoarchitecture and the precise genetic control of this phase remains largely unknown. Thus, this review article focuses on the multipolar phase in the developing neocortex. It begins by summarizing the molecular mechanism that underlies multipolar migration for the regulation of each step in multipolar phase in intermediate zone. The physiological significance of this multipolar phase in the establishment of mature cortical lamination and neurodevelopmental disorders associated with migration defects is then described. © 2017 Molecular Biology Society of Japan and John Wiley & Sons Australia, Ltd.
NASA Astrophysics Data System (ADS)
Vidmar, David; Narayan, Sanjiv M.; Krummen, David E.; Rappel, Wouter-Jan
2016-11-01
We present a general method of utilizing bioelectric recordings from a spatially sparse electrode grid to compute a dynamic vector field describing the underlying propagation of electrical activity. This vector field, termed the wave-front flow field, permits quantitative analysis of the magnitude of rotational activity (vorticity) and focal activity (divergence) at each spatial point. We apply this method to signals recorded during arrhythmias in human atria and ventricles using a multipolar contact catheter and show that the flow fields correlate with corresponding activation maps. Further, regions of elevated vorticity and divergence correspond to sites identified as clinically significant rotors and focal sources where therapeutic intervention can be effective. These flow fields can provide quantitative insights into the dynamics of normal and abnormal conduction in humans and could potentially be used to enhance therapies for cardiac arrhythmias.
Ware, Taylor; Simon, Dustin; Hearon, Keith; Liu, Clive; Shah, Sagar; Reeder, Jonathan; Khodaparast, Navid; Kilgard, Michael P; Maitland, Duncan J; Rennaker, Robert L; Voit, Walter E
2012-12-01
Planar electronics processing methods have enabled neural interfaces to become more precise and deliver more information. However, this processing paradigm is inherently 2D and rigid. The resulting mechanical and geometrical mismatch at the biotic-abiotic interface can elicit an immune response that prevents effective stimulation. In this work, a thiol-ene/acrylate shape memory polymer is utilized to create 3D softening substrates for stimulation electrodes. This substrate system is shown to soften in vivo from more than 600 to 6 MPa. A nerve cuff electrode that coils around the vagus nerve in a rat and that drives neural activity is demonstrated.
Kenney, Laurence P; Heller, Ben W; Barker, Anthony T; Reeves, Mark L; Healey, Jamie; Good, Timothy R; Cooper, Glen; Sha, Ning; Prenton, Sarah; Liu, Anmin; Howard, David
2016-11-01
Functional electrical stimulation has been shown to be a safe and effective means of correcting foot drop of central neurological origin. Current surface-based devices typically consist of a single channel stimulator, a sensor for determining gait phase and a cuff, within which is housed the anode and cathode. The cuff-mounted electrode design reduces the likelihood of large errors in electrode placement, but the user is still fully responsible for selecting the correct stimulation level each time the system is donned. Researchers have investigated different approaches to automating aspects of setup and/or use, including recent promising work based on iterative learning techniques. This paper reports on the design and clinical evaluation of an electrode array-based FES system for the correction of drop foot, ShefStim. The paper reviews the design process from proof of concept lab-based study, through modelling of the array geometry and interface layer to array search algorithm development. Finally, the paper summarises two clinical studies involving patients with drop foot. The results suggest that the ShefStim system with automated setup produces results which are comparable with clinician setup of conventional systems. Further, the final study demonstrated that patients can use the system without clinical supervision. When used unsupervised, setup time was 14min (9min for automated search plus 5min for donning the equipment), although this figure could be reduced significantly with relatively minor changes to the design. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Makeyev, Oleksandr; Lee, Colin; Besio, Walter G
2017-07-01
Tripolar concentric ring electrodes are showing great promise in a range of applications including braincomputer interface and seizure onset detection due to their superiority to conventional disc electrodes, in particular, in accuracy of surface Laplacian estimation. Recently, we proposed a general approach to estimation of the Laplacian for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method for n ≥ 2 that allows cancellation of all the truncation terms up to the order of 2n. This approach has been used to introduce novel multipolar and variable inter-ring distances concentric ring electrode configurations verified using finite element method. The obtained results suggest their potential to improve Laplacian estimation compared to currently used constant interring distances tripolar concentric ring electrodes. One of the main limitations of the proposed (4n + 1)-point method is that the radius of the central disc and the widths of the concentric rings are not included and therefore cannot be optimized. This study incorporates these two parameters by representing the central disc and both concentric rings as clusters of points with specific radius and widths respectively as opposed to the currently used single point and concentric circles. A proof of concept Laplacian estimate is derived for a tripolar concentric ring electrode with non-negligible radius of the central disc and non-negligible widths of the concentric rings clearly demonstrating how both of these parameters can be incorporated into the (4n + 1)-point method.
Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants
NASA Astrophysics Data System (ADS)
Wilke, R. G. H.; Khalili Moghadam, G.; Lovell, N. H.; Suaning, G. J.; Dokos, S.
2011-08-01
Active multi-electrode arrays are used in vision prostheses, including optic nerve cuffs and cortical and retinal implants for stimulation of neural tissue. For retinal implants, arrays with up to 1500 electrodes are used in clinical trials. The ability to convey information with high spatial resolution is critical for these applications. To assess the extent to which spatial resolution is impaired by electric crosstalk, finite-element simulation of electric field distribution in a simplified passive tissue model of the retina is performed. The effects of electrode size, electrode spacing, distance to target cells, and electrode return configuration (monopolar, tripolar, hexagonal) on spatial resolution is investigated in the form of a mathematical model of electric field distribution. Results show that spatial resolution is impaired with increased distance from the electrode array to the target cells. This effect can be partly compensated by non-monopolar electrode configurations and larger electrode diameters, albeit at the expense of lower pixel densities due to larger covering areas by each stimulation electrode. In applications where multi-electrode arrays can be brought into close proximity to target cells, as presumably with epiretinal implants, smaller electrodes in monopolar configuration can provide the highest spatial resolution. However, if the implantation site is further from the target cells, as is the case in suprachoroidal approaches, hexagonally guarded electrode return configurations can convey higher spatial resolution. This paper was originally submitted for the special issue containing contributions from the Sixth Biennial Research Congress of The Eye and the Chip.
Mapping of the human upper arm muscle activity with an electrode matrix.
Côté, J; Mathieu, P A
2000-06-01
Surface electrode matrices allow measurement of muscle activity while avoiding certain hazardous risks and inconvenience associated with invasive techniques. Major challenges of such equipment involve optimizing spatial resolution, and designing simple acquisition systems able to record simultaneously many potentials over large anatomical areas. We present a surface electromyography acquisition system comprising of 3 x 8 Ag-AgCl electrodes mounted onto an elastic band, which can be adjusted to fit an entire human upper limb segment. Using this equipment, we acquired a simultaneous representation of muscular activity from a segment of the upper limb surface of 6 healthy subjects during isometric contractions at various intensities. We found that the location of regions of highest activity depended on elbow torque direction but also varied among subjects. Signals obtained with such equipment can be used to solve the inverse problem and help optimize the electrode configuration in volume conduction studies. The efficacy of decision algorithms of multi-functional myoelectric prostheses can be tested with the global muscle activity patterns gathered. The electrode cuff could also be used in the investigation of fatigue and injury mechanisms during occupational activities.
Heiser, Clemens; Knopf, Andreas; Hofauer, Benedikt
2017-12-01
Selective upper airway stimulation (UAS) has shown effectiveness in treating patients with obstructive sleep apnea (OSA). The terminating branches of the hypoglossal nerve show a wide complexity, requiring careful discernment of a functional breakpoint between branches for inclusion and exclusion from the stimulation cuff electrode. The purpose of this study was to describe and categorize the topographic phenotypes of these branches. Thirty patients who received an implant with selective UAS from July 2015 to June 2016 were included. All implantations were recorded using a microscope and resultant tongue motions were captured perioperatively for comparison. Eight different variations of the branches were encountered and described, both in a tabular numeric fashion and in pictorial schema. The examinations showed the complex phenotypic surgical anatomy of the hypoglossal nerve. A schematic classification system has been developed to help surgeons identify the optimal location for cuff placement in UAS. © 2017 Wiley Periodicals, Inc.
2012-01-01
The control of robotic prostheses based on pattern recognition algorithms is a widely studied subject that has shown promising results in acute experiments. The long-term implementation of this technology, however, has not yet been achieved due to practical issues that can be mainly attributed to the use of surface electrodes and their highly environmental dependency. This paper describes several implantable electrodes and discusses them as a solution for the natural control of artificial limbs. In this context “natural” is defined as producing control over limb movement analogous to that of an intact physiological system. This includes coordinated and simultaneous movements of different degrees of freedom. It also implies that the input signals must come from nerves or muscles that were originally meant to produce the intended movement and that feedback is perceived as originating in the missing limb without requiring burdensome levels of concentration. After scrutinizing different electrode designs and their clinical implementation, we concluded that the epimysial and cuff electrodes are currently promising candidates to achieving a long-term stable and natural control of robotic prosthetics, provided that communication from the electrodes to the outside of the body is guaranteed. PMID:22715940
Selective electrical interfaces with the nervous system.
Rutten, Wim L C
2002-01-01
To achieve selective electrical interfacing to the neural system it is necessary to approach neuronal elements on a scale of micrometers. This necessitates microtechnology fabrication and introduces the interdisciplinary field of neurotechnology, lying at the juncture of neuroscience with microtechnology. The neuroelectronic interface occurs where the membrane of a cell soma or axon meets a metal microelectrode surface. The seal between these may be narrow or may be leaky. In the latter case the surrounding volume conductor becomes part of the interface. Electrode design for successful interfacing, either for stimulation or recording, requires good understanding of membrane phenomena, natural and evoked action potential generation, volume conduction, and electrode behavior. Penetrating multimicroelectrodes have been produced as one-, two-, and three-dimensional arrays, mainly in silicon, glass, and metal microtechnology. Cuff electrodes circumvent a nerve; their selectivity aims at fascicles more than at nerve fibers. Other types of electrodes are regenerating sieves and cone-ingrowth electrodes. The latter may play a role in brain-computer interfaces. Planar substrate-embedded electrode arrays with cultured neural cells on top are used to study the activity and plasticity of developing neural networks. They also serve as substrates for future so-called cultured probes.
An Implantable Neuroprosthetic Device to Normalize Bladder Function after SCI
2012-10-01
Billington, K.S. Tweden, R.R. Wilson, F.G. Moody, “Selection of electrical algorithms to treat obesity with intermittent vagal block using an...C.J., Tweden, K.S., Wilson, R.R., Moody, F.G. (2009). Selection of electrical algorithms to treat obesity with intermittent vagal block using an...only one cuff electrode was implanted on the left pudendal nerve. Therefore, voiding induced by intermittent stimulation was tested but pudendal
Silkworth, William T.; Nardi, Isaac K.; Scholl, Lindsey M.; Cimini, Daniela
2009-01-01
Many cancer cells display a CIN (Chromosome Instability) phenotype, by which they exhibit high rates of chromosome loss or gain at each cell cycle. Over the years, a number of different mechanisms, including mitotic spindle multipolarity, cytokinesis failure, and merotelic kinetochore orientation, have been proposed as causes of CIN. However, a comprehensive theory of how CIN is perpetuated is still lacking. We used CIN colorectal cancer cells as a model system to investigate the possible cellular mechanism(s) underlying CIN. We found that CIN cells frequently assembled multipolar spindles in early mitosis. However, multipolar anaphase cells were very rare, and live-cell experiments showed that almost all CIN cells divided in a bipolar fashion. Moreover, fixed-cell analysis showed high frequencies of merotelically attached lagging chromosomes in bipolar anaphase CIN cells, and higher frequencies of merotelic attachments in multipolar vs. bipolar prometaphases. Finally, we found that multipolar CIN prometaphases typically possessed γ-tubulin at all spindle poles, and that a significant fraction of bipolar metaphase/early anaphase CIN cells possessed more than one centrosome at a single spindle pole. Taken together, our data suggest a model by which merotelic kinetochore attachments can easily be established in multipolar prometaphases. Most of these multipolar prometaphase cells would then bi-polarize before anaphase onset, and the residual merotelic attachments would produce chromosome mis-segregation due to anaphase lagging chromosomes. We propose this spindle pole coalescence mechanism as a major contributor to chromosome instability in cancer cells. PMID:19668340
The Role of Angular Momentum in the Construction of Electromagnetic Multipolar Fields
ERIC Educational Resources Information Center
Tischler, Nora; Zambrana-Puyalto, Xavier; Molina-Terriza, Gabriel
2012-01-01
Multipolar solutions of Maxwell's equations are used in many practical applications and are essential for the understanding of light-matter interactions at the fundamental level. Unlike the set of plane wave solutions of electromagnetic fields, the multipolar solutions do not share a standard derivation or notation. As a result, expressions…
Modeling the response of small myelinated axons in a compound nerve to kilohertz frequency signals
NASA Astrophysics Data System (ADS)
Pelot, N. A.; Behrend, C. E.; Grill, W. M.
2017-08-01
Objective. There is growing interest in electrical neuromodulation of peripheral nerves, particularly autonomic nerves, to treat various diseases. Electrical signals in the kilohertz frequency (KHF) range can produce different responses, including conduction block. For example, EnteroMedics’ vBloc® therapy for obesity delivers 5 kHz stimulation to block the abdominal vagus nerves, but the mechanisms of action are unclear. Approach. We developed a two-part computational model, coupling a 3D finite element model of a cuff electrode around the human abdominal vagus nerve with biophysically-realistic electrical circuit equivalent (cable) model axons (1, 2, and 5.7 µm in diameter). We developed an automated algorithm to classify conduction responses as subthreshold (transmission), KHF-evoked activity (excitation), or block. We quantified neural responses across kilohertz frequencies (5-20 kHz), amplitudes (1-8 mA), and electrode designs. Main results. We found heterogeneous conduction responses across the modeled nerve trunk, both for a given parameter set and across parameter sets, although most suprathreshold responses were excitation, rather than block. The firing patterns were irregular near transmission and block boundaries, but otherwise regular, and mean firing rates varied with electrode-fibre distance. Further, we identified excitation responses at amplitudes above block threshold, termed ‘re-excitation’, arising from action potentials initiated at virtual cathodes. Excitation and block thresholds decreased with smaller electrode-fibre distances, larger fibre diameters, and lower kilohertz frequencies. A point source model predicted a larger fraction of blocked fibres and greater change of threshold with distance as compared to the realistic cuff and nerve model. Significance. Our findings of widespread asynchronous KHF-evoked activity suggest that conduction block in the abdominal vagus nerves is unlikely with current clinical parameters. Our results indicate that compound neural or downstream muscle force recordings may be unreliable as quantitative measures of neural activity for in vivo studies or as biomarkers in closed-loop clinical devices.
Modeling the response of small myelinated axons in a compound nerve to kilohertz frequency signals.
Pelot, N A; Behrend, C E; Grill, W M
2017-08-01
There is growing interest in electrical neuromodulation of peripheral nerves, particularly autonomic nerves, to treat various diseases. Electrical signals in the kilohertz frequency (KHF) range can produce different responses, including conduction block. For example, EnteroMedics' vBloc ® therapy for obesity delivers 5 kHz stimulation to block the abdominal vagus nerves, but the mechanisms of action are unclear. We developed a two-part computational model, coupling a 3D finite element model of a cuff electrode around the human abdominal vagus nerve with biophysically-realistic electrical circuit equivalent (cable) model axons (1, 2, and 5.7 µm in diameter). We developed an automated algorithm to classify conduction responses as subthreshold (transmission), KHF-evoked activity (excitation), or block. We quantified neural responses across kilohertz frequencies (5-20 kHz), amplitudes (1-8 mA), and electrode designs. We found heterogeneous conduction responses across the modeled nerve trunk, both for a given parameter set and across parameter sets, although most suprathreshold responses were excitation, rather than block. The firing patterns were irregular near transmission and block boundaries, but otherwise regular, and mean firing rates varied with electrode-fibre distance. Further, we identified excitation responses at amplitudes above block threshold, termed 're-excitation', arising from action potentials initiated at virtual cathodes. Excitation and block thresholds decreased with smaller electrode-fibre distances, larger fibre diameters, and lower kilohertz frequencies. A point source model predicted a larger fraction of blocked fibres and greater change of threshold with distance as compared to the realistic cuff and nerve model. Our findings of widespread asynchronous KHF-evoked activity suggest that conduction block in the abdominal vagus nerves is unlikely with current clinical parameters. Our results indicate that compound neural or downstream muscle force recordings may be unreliable as quantitative measures of neural activity for in vivo studies or as biomarkers in closed-loop clinical devices.
Alenabi, Talia; Dal Maso, Fabien; Tétreault, Patrice; Begon, Mickaël
2016-02-01
Arm elevations in different planes are commonly assessed in clinics and are included in rehabilitation protocols for patients with rotator cuff pathology. The aim of this study was to quantify the effect of plane and angle of elevation on shoulder muscles activity in patients with symptomatic rotator cuff tear to be used for rehabilitation purposes. Eight symptomatic patients with rotator cuff tears were assessed by using EMG (11 surface and 2 fine wire electrodes) synchronized with a motion analysis. The subjects completed five elevations in full can position (arm externally rotated and thumb up) in frontal, scapular and sagittal planes. Muscle activity in three elevation arcs of 20° (from 0° to 60°) was presented as the percentage of mean activity. Data were analyzed by mixed linear models (α=0.003), and Tuckey Post-hoc comparisons for significant effects (α=0.05). The effect of plane was significant for supraspinatus, middle trapezius, anterior, middle, and posterior deltoid, triceps, and pectoralis major (P<0.001). Supraspinatus was more active during abduction than scaption and flexion (P<0.05), and its activity did not increase significantly after 40° of elevation (P>0.05). Infraspinatus had similar activity pattern in the three planes of elevation (P>0.003) with increasing trend in accordance with the elevation angle. In any rehabilitation protocol, if less activity of supraspinatus is desired, active arm elevation should be directed toward flexion and scaption and postponed abduction to prevent high level of activity in this muscle. Copyright © 2015 Elsevier Ltd. All rights reserved.
Sevcencu, Cristian; Nielsen, Thomas N; Kjaergaard, Benedict; Struijk, Johannes J
2018-04-01
Left vagus nerve (LVN) stimulation (LVNS) has been tested for lowering the blood pressure (BP) in patients with resistant hypertension (RH). Whereas, closed-loop LVNS (CL-LVNS) driven by a BP marker may be superior to open-loop LVNS, there are situations (e.g., exercising) when hypertension is normal. Therefore, an ideal anti-RH CL-LVNS system requires a variable to avoid stimulation in such conditions, for example, a respiratory marker ideally extracted from the LVN. As the LVN conducts respiratory signals, this study aimed to investigate if such signals can be recorded using implantable means and if a marker to monitor respiration could be derived from such recordings. The experiments were performed in 14 anesthetized pigs. Five pigs were subjected to changes of the respiratory frequency and nine to changes of the respiratory volume. The LVN electroneurogram (VENG) was recorded using two cuff electrodes and the respiratory cycles (RC) using a pressure transducer. To separate the afferent and efferent VENGs, vagotomy was performed between the cuffs in the first group of pigs. The VENG was squared to derive respiration-related neural profiles (RnPs) and their correlation with the RCs was investigated in regard to timing and magnitude parameters derived from the two waveforms. The RnPs were morphologically similar with the RCs and the average RnPs represented accurate copies of the average RCs. Consequently, the lung inflation/deflation RC and RnP components had the same duration, the respiratory frequency changes affected in the same way both waveforms and the RnP amplitude increased linearly with the lung inflation in all tested pigs (R 2 values between 0.85 and 0.99). The RnPs comprise information regarding the timing and magnitude of the respiratory parameters. As those LVN profiles were derived using implantable means, this study indicates that the RnPs could serve as respiratory markers in implantable systems. © 2017 International Neuromodulation Society.
Wang, Y. L.; Fabbris, G.; Meyers, D.; ...
2017-08-30
Resonant elastic x-ray scattering is a powerful technique for measuring multipolar order parameters. In this paper, we theoretically and experimentally study the possibility of using this technique to detect the proposed multipolar order parameters in URu 2 Si 2 at the U- L 3 edge with the electric quadrupolar transition. Based on an atomic model, we calculate the azimuthal dependence of the quadrupolar transition at the U- L 3 edge. Our results illustrate the potential of this technique for distinguishing different multipolar order parameters. We then perform experiments on ultraclean single crystals of URu 2 Si 2 at the U-more » L 3 edge to search for the predicted signal, but do not detect any indications of multipolar moments within the experimental uncertainty. We also theoretically estimate the orders of magnitude of the cross section and the expected count rate of the quadrupolar transition and compare them to the dipolar transitions at the U- M 4 and U- L 3 edges, clarifying the difficulty in detecting higher order multipolar order parameters in URu 2 Si 2 in the current experimental setup.« less
Nielsen, Thomas N; Sevcencu, Cristian; Struijk, Johannes J
2014-01-01
Previous studies have indicated that electrodes placed between fascicles can provide nerve recruitment with high topological selectivity if the areas of interest in the nerve are separated with passive elements. In this study, we investigated if this separation of fascicles also can provide topologically selective nerve recordings and compared the performance of mono-, bi-, and tripolar configurations for stimulation and recording with an intra-neural interface. The interface was implanted in the sciatic nerve of 10 rabbits and achieved a median selectivity of Ŝ=0.98-0.99 for all stimulation configurations, while recording selectivity configurations was in the range of Ŝ=0.70-0.80 with the monopolar configuration providing the lowest and the average reference configuration the highest recording selectivity. Interfascicular electrodes could provide an interesting addition to the bulk of peripheral nerve interfaces available for neural prosthetic devices. The separation of the nerve into chambers by the passive elements of the electrode could ensure a higher selectivity than comparable cuff electrodes and the intra-neural location could provide an option of targeting mainly central fascicles. Further studies are, however, still required to develop biocompatible electrodes and test their stability and safety in chronic experiments.
Micromachined devices for interfacing neurons
NASA Astrophysics Data System (ADS)
Stieglitz, Thomas; Beutel, Hansjoerg; Blau, Cornelia; Meyer, Joerg-Uwe
1998-07-01
Micromachining technologies were established to fabricate microelectrode arrays and devices for interfacing parts of the central or peripheral nervous system. The devices were part of a neural prosthesis that allows simultaneous multichannel recording and multisite stimulation of neurons. Overcoming the brittle mechanics of silicon devices and challenging housing demands close to the nerve we established a process technology to fabricate light-weighted and highly flexible polyimide based devices. Platinum and iridium thin-film electrodes were embedded in the polyimide. With reactive ion etching we got the possibility to simply integrate interconnections and to form nearly arbitrary outer shapes of the devices. We designed multichannel devices with up to 24 electrodes in the shape of plates, hooks and cuffs for different applications. In vitro tests exhibited stable electrode properties and no cytotoxicity of the materials and the devices. Sieve electrodes were chronically implanted in rats to interface the regenerating sciatic nerve. After six months, recordings and stimulation of the nerve via electrodes on the micro-device proved functional reinnervation of the limb. Concentric circular structures were designed for a retina implant for the blind. In preliminary studies in rabbits, evoked potentials in the visual cortex corresponded to stimulation sites of the implant.
Muscular Activation During Plyometric Exercises in 90° of Glenohumeral Joint Abduction
Ellenbecker, Todd S.; Sueyoshi, Tetsuro; Bailie, David S.
2015-01-01
Background: Plyometric exercises are frequently used to increase posterior rotator cuff and periscapular muscle strength and simulate demands and positional stresses in overhead athletes. The purpose of this study was to provide descriptive data on posterior rotator cuff and scapular muscle activation during upper extremity plyometric exercises in 90° of glenohumeral joint abduction. Hypothesis: Levels of muscular activity in the posterior rotator cuff and scapular stabilizers will be high during plyometric shoulder exercises similar to previously reported electromyographic (EMG) levels of shoulder rehabilitation exercises. Study Design: Descriptive laboratory study. Methods: Twenty healthy subjects were tested using surface EMG during the performance of 2 plyometric shoulder exercises: prone external rotation (PERP) and reverse catch external rotation (RCP) using a handheld medicine ball. Electrode application included the upper and lower trapezius (UT and LT, respectively), serratus anterior (SA), infraspinatus (IN), and the middle and posterior deltoid (MD and PD, respectively) muscles. A 10-second interval of repetitive plyometric exercise (PERP) and 3 repetitions of RCP were sampled. Peak and average normalized EMG data were generated. Results: Normalized peak and average IN activity ranged between 73% and 102% and between 28% and 52% during the plyometric exercises, respectively, with peak and average LT activity measured between 79% and 131% and between 31% and 61%. SA activity ranged between 76% and 86% for peak and between 35% and 37% for average activity. Muscular activity levels in the MD and PD ranged between 49% and 72% and between 12% and 33% for peak and average, respectively. Conclusion: Moderate to high levels of muscular activity were measured in the rotator cuff and scapular stabilizers during these plyometric exercises with the glenohumeral joint abducted 90°. PMID:25553216
Muscular activation during plyometric exercises in 90° of glenohumeral joint abduction.
Ellenbecker, Todd S; Sueyoshi, Tetsuro; Bailie, David S
2015-01-01
Plyometric exercises are frequently used to increase posterior rotator cuff and periscapular muscle strength and simulate demands and positional stresses in overhead athletes. The purpose of this study was to provide descriptive data on posterior rotator cuff and scapular muscle activation during upper extremity plyometric exercises in 90° of glenohumeral joint abduction. Levels of muscular activity in the posterior rotator cuff and scapular stabilizers will be high during plyometric shoulder exercises similar to previously reported electromyographic (EMG) levels of shoulder rehabilitation exercises. Descriptive laboratory study. Twenty healthy subjects were tested using surface EMG during the performance of 2 plyometric shoulder exercises: prone external rotation (PERP) and reverse catch external rotation (RCP) using a handheld medicine ball. Electrode application included the upper and lower trapezius (UT and LT, respectively), serratus anterior (SA), infraspinatus (IN), and the middle and posterior deltoid (MD and PD, respectively) muscles. A 10-second interval of repetitive plyometric exercise (PERP) and 3 repetitions of RCP were sampled. Peak and average normalized EMG data were generated. Normalized peak and average IN activity ranged between 73% and 102% and between 28% and 52% during the plyometric exercises, respectively, with peak and average LT activity measured between 79% and 131% and between 31% and 61%. SA activity ranged between 76% and 86% for peak and between 35% and 37% for average activity. Muscular activity levels in the MD and PD ranged between 49% and 72% and between 12% and 33% for peak and average, respectively. Moderate to high levels of muscular activity were measured in the rotator cuff and scapular stabilizers during these plyometric exercises with the glenohumeral joint abducted 90°.
Sardu, Celestino; Barbieri, Michelangela; Santamaria, Matteo; Giordano, Valerio; Sacra, Cosimo; Paolisso, Pasquale; Spirito, Alessandro; Marfella, Raffaele; Paolisso, Giuseppe; Rizzo, Maria Rosaria
2017-06-09
Type 2 diabetes mellitus (T2DM) is a multi factorial disease, affecting clinical outcomes in failing heart patients treated by cardiac resynchronization therapy with a defibrillator (CRT-d). One hundred and ninety-five T2DM patients received a CRT-d treatment. Randomly the study population received a CRT-d via multipolar left ventricle (LV) lead pacing (n 99, multipolar group), vs a CRT-d via bipolar LV pacing (n 96, bipolar group). These patients were followed by clinical, and instrumental assessment, and telemetric device control at follow up. In this study we evaluated, in a population of failing heart T2DM patients, cardiac deaths, all cause deaths, arrhythmic events, CRT-d responders rate, hospitalizations for HF worsening, phrenic nerve stimulation (PNS), and LV catheter dislodgment events (and re-intervention for LV catheter re-positioning), comparing multipolar CRT-d vs bipolar CRT-d group of patients at follow up. At follow up there was a statistical significant difference about atrial arrhythmic events [7 (7%) vs 16 (16.7%), p value 0.019], hospitalizations for HF worsening [15 (15.2% vs 24 (25%), p value 0.046], LV catheter dislodgments [1 (1%) vs 9 (9.4%), p value 0018], PNS [5 (5%) vs 18 (18.7%), p value 0.007], and LV re-positioning [1 (1%) vs 9 (9.4%), p value 0.018], comparing multipolar CRT-d vs bipolar CRT-d group of patients. Multipolar pacing was an independent predictor of all these events. CRT-d pacing via multipolar LV lead vs bipolar LV lead may reduce arrhythmic burden, hospitalization rate, PNS, LV catheters dislodgments, and re-interventions in T2DM failing heart patients. Clinical trial number NCT03095196.
De-May, C.L.; Ali, A.B.
2013-01-01
To investigate the involvement of N-Methyl-D-aspartate (NMDA) receptors in local neocortical synaptic transmission, dual whole-cell recordings – combined with biocytin labelling – were obtained from bitufted adapting, multipolar adapting or multipolar non-adapting interneurons and pyramidal cells in layers II–V of rat (postnatal days 17–22) sensorimotor cortex. The voltage dependency of the amplitude of Excitatory postsynaptic potentials (EPSPs) received by the three types of interneuron appeared to coincide with the interneuron subclass; upon depolarisation, EPSPs received by multipolar non-adapting interneurons either decreased in amplitude or appeared insensitive, multipolar adapting interneuron EPSP amplitudes increased or appeared insensitive, whereas bitufted interneuron EPSP amplitudes increased or decreased. Connections were challenged with the NMDA receptor antagonist d-(−)-2-amino-5-phosphonopentanoic acid (d-AP5) (50 μM) revealing NMDA receptors to contribute to EPSPs received by all cell types, this also abolished the non-conventional voltage dependency. Reciprocal connections were frequent between pyramidal cells and multipolar interneurons, and inhibitory postsynaptic potentials (IPSPs) elicited in pyramidal cells by both multipolar adapting and multipolar non-adapting interneurons were sensitive to a significant reduction in amplitude by d-AP5. The involvement of presynaptic NMDA receptors was indicated by coefficient of variation analysis and an increase in the failures of transmission. Furthermore, by loading MK-801 into the pre- or postsynaptic neurons, we observed that a reduction in inhibition requires presynaptic and not postsynaptic NMDA receptors. These results suggest that NMDA receptors possess pre- and postsynaptic roles at selective neocortical synapses that are probably important in governing spike-timing and information flow. PMID:23079623
NASA Astrophysics Data System (ADS)
Yao, Guang-Rui; Huang, Lei; Yu, Cong; Shen, Zhi-Qiang
2018-02-01
We have analyzed the multipolar magnetic field structure variation at neutron star surface by means of the catastrophic eruption model and find that the variation of the geometry of multipolar fields on the magnetar surface could result in the catastrophic rearrangement of the magnetosphere, which provides certain physical mechanism for the outburst of giant flares. The magnetospheric model we adopted consists of two assumptions: (1) a helically twisted flux rope is suspended in an ideal force-free magnetosphere around the magnetar, and (2) a current sheet emerges during the flux rope evolution. Magnetic energy accumulates during the flux rope’s gradual evolution along with the variation of magnetar surface magnetic structure before the eruption. The two typical behaviors, either state transition or catastrophic escape, would take place once the flux rope loses equilibrium; thus, tremendous accumulated energy is radiated. We have investigated the equilibrium state of the flux rope and the energy release affected by different multipolar structures and find structures that could trigger violent eruption and provide the radiation approximately 0.5% of the total magnetic energy during the giant flare outburst. Our results provide certain multipolar structures of the neutron star’s magnetic field with an energy release percentage 0.42% in the state transition and 0.51% in the catastrophic escape case, which are sufficient for the previously reported energy release from SGR 1806–20 giant flares.
Structuring Light to Manipulate Multipolar Resonances for Metamaterial Applications
NASA Astrophysics Data System (ADS)
Das, Tanya
Multipolar electromagnetic phenomena in sub-wavelength resonators are at the heart of metamaterial science and technology. Typically, researchers engineer multipolar light-matter interactions by modifying the size, shape, and composition of the resonators. Here, we instead engineer multipolar interactions by modifying properties of the incident radiation. In this dissertation, we propose a new framework for determining the scattering response of resonators based on properties of the local excitation field. First, we derive an analytical theory to determine the scattering response of spherical nanoparticles under any type of illumination. Using this theory, we demonstrate the ability to drastically manipulate the scattering properties of a spherical nanoparticle by varying the illumination and demonstrate excitation of a longitudinal quadrupole mode that cannot be accessed with conventional illumination. Next, we investigate the response of dielectric dimer structures illuminated by cylindrical vector beams. Using finite-difference time-domain simulations, we demonstrate significant modification of the scattering spectra of dimer antennas and reveal how the illumination condition gives rise to these spectra through manipulation of electric and magnetic mode hybridization. Finally, we present a simple and efficient numerical simulation based on local field principles for extracting the multipolar response of any resonator under illumination by structured light. This dissertation enhances the understanding of fundamental light-matter interactions in metamaterials and lays the foundation for researchers to identify, quantify, and manipulate multipolar light-matter interactions through optical beam engineering.
Multipolar mitosis of tetraploid cells: inhibition by p53 and dependency on Mos.
Vitale, Ilio; Senovilla, Laura; Jemaà, Mohamed; Michaud, Mickaël; Galluzzi, Lorenzo; Kepp, Oliver; Nanty, Lisa; Criollo, Alfredo; Rello-Varona, Santiago; Manic, Gwenola; Métivier, Didier; Vivet, Sonia; Tajeddine, Nicolas; Joza, Nicholas; Valent, Alexander; Castedo, Maria; Kroemer, Guido
2010-04-07
Tetraploidy can constitute a metastable intermediate between normal diploidy and oncogenic aneuploidy. Here, we show that the absence of p53 is not only permissive for the survival but also for multipolar asymmetric divisions of tetraploid cells, which lead to the generation of aneuploid cells with a near-to-diploid chromosome content. Multipolar mitoses (which reduce the tetraploid genome to a sub-tetraploid state) are more frequent when p53 is downregulated and the product of the Mos oncogene is upregulated. Mos inhibits the coalescence of supernumerary centrosomes that allow for normal bipolar mitoses of tetraploid cells. In the absence of p53, Mos knockdown prevents multipolar mitoses and exerts genome-stabilizing effects. These results elucidate the mechanisms through which asymmetric cell division drives chromosomal instability in tetraploid cells.
Coupled multipolar interactions in small-particle metallic clusters.
Pustovit, Vitaly N; Sotelo, Juan A; Niklasson, Gunnar A
2002-03-01
We propose a new formalism for computing the optical properties of small clusters of particles. It is a generalization of the coupled dipole-dipole particle-interaction model and allows one in principle to take into account all multipolar interactions in the long-wavelength limit. The method is illustrated by computations of the optical properties of N = 6 particle clusters for different multipolar approximations. We examine the effect of separation between particles and compare the optical spectra with the discrete-dipole approximation and the generalized Mie theory.
Steffen, Armin; Kilic, Ayse; König, Inke R; Suurna, Maria V; Hofauer, Benedikt; Heiser, Clemens
2017-12-27
Upper airway stimulation (UAS) is an effective treatment for obstructive sleep apnea (OSA). Previous data have demonstrated a correlation between the phenotype of tongue motion and therapy response. Closed loop hypoglossal nerve stimulation implant offers five different electrode configuration settings which may result in different tongue motion. Two-center, prospective consecutive trial in a university hospital setting. Clinical outcomes of 35 patients were analyzed after at least 12 months of device use. Tongue motion was assessed at various electrode configuration settings. Correlation between the tongue motion and treatment response was evaluated. OSA severity was significantly reduced with the use of UAS therapy (P < .001). Changes in tongue motion patterns were frequently observed (58.8%) with different electrode configuration settings. Most of the patients alternated between right and bilateral protrusion (73.5%), which are considered to be the optimal phenotypes for selective UAS responses. Different voltage settings were required to achieve functional stimulation levels when changing between the electrode settings. UAS is highly effective for OSA treatment in selected patients with an apnea-hypopnea index between 15 and 65 events per hour and higher body mass index. Attention should be given to patients with shifting tongue movement in response to change of electrode configuration. The intraoperative cuff placement should be reassessed when tongue movement shifting is observed. 4 Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Miniaturized neural interfaces and implants
NASA Astrophysics Data System (ADS)
Stieglitz, Thomas; Boretius, Tim; Ordonez, Juan; Hassler, Christina; Henle, Christian; Meier, Wolfgang; Plachta, Dennis T. T.; Schuettler, Martin
2012-03-01
Neural prostheses are technical systems that interface nerves to treat the symptoms of neurological diseases and to restore sensory of motor functions of the body. Success stories have been written with the cochlear implant to restore hearing, with spinal cord stimulators to treat chronic pain as well as urge incontinence, and with deep brain stimulators in patients suffering from Parkinson's disease. Highly complex neural implants for novel medical applications can be miniaturized either by means of precision mechanics technologies using known and established materials for electrodes, cables, and hermetic packages or by applying microsystems technologies. Examples for both approaches will be introduced and discussed. Electrode arrays for recording of electrocorticograms during presurgical epilepsy diagnosis have been manufactured using approved materials and a marking laser to achieve an integration density that is adequate in the context of brain machine interfaces, e.g. on the motor cortex. Microtechnologies have to be used for further miniaturization to develop polymer-based flexible and light weighted electrode arrays to interface the peripheral and central nervous system. Polyimide as substrate and insulation material will be discussed as well as several application examples for nerve interfaces like cuffs, filament like electrodes and large arrays for subdural implantation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mosher, J. C.; Baillet, S.; Jerbi, K.
2001-01-01
We describe the use of truncated multipolar expansions for producing dynamic images of cortical neural activation from measurements of the magnetoencephalogram. We use a signal-subspace method to find the locations of a set of multipolar sources, each of which represents a region of activity in the cerebral cortex. Our method builds up an estimate of the sources in a recursive manner, i.e. we first search for point current dipoles, then magnetic dipoles, and finally first order multipoles. The dynamic behavior of these sources is then computed using a linear fit to the spatiotemporal data. The final step in the proceduremore » is to map each of the multipolar sources into an equivalent distributed source on the cortical surface. The method is illustrated through an application to epileptic interictal MEG data.« less
Yoles-Frenkel, Michal; Cohen, Oksana; Bansal, Rohini; Horesh, Noa; Ben-Shaul, Yoram
2017-06-15
Achieving controlled stimulus delivery is a major challenge in the physiological analysis of the vomeronasal system (VNS). We provide a comprehensive description of a setup allowing controlled stimulus delivery into the vomeronasal organ (VNO) of anesthetized mice. VNO suction is achieved via electrical stimulation of the sympathetic nerve trunk (SNT) using cuff electrodes, followed by flushing of the nasal cavity. Successful application of this methodology depends on several aspects including the surgical preparation, fabrication of cuff electrodes, experimental setup modifications, and the stimulus delivery and flushing. Here, we describe all these aspects in sufficient detail to allow other researchers to readily adopt it. We also present a custom written MATLAB based software with a graphical user interface that controls all aspects of the actual experiment, including trial sequencing, hardware control, and data logging. The method allows measurement of stimulus evoked sensory responses in brain regions that receive vomeronasal inputs. An experienced investigator can complete the entire surgical procedure within thirty minutes. This is the only approach that allows repeated and controlled stimulus delivery to the intact VNO, employing the natural mode of stimulus uptake. The approach is economical with respect to stimuli, requiring stimulus volumes as low as 1-2μl. This comprehensive description will allow other investigators to adapt this setup to their own experimental needs and can thus promote our physiological understanding of this fascinating chemosensory system. With minor changes it can also be adapted for other rodent species. Copyright © 2017 Elsevier B.V. All rights reserved.
Stieglitz, T; Schuettler, M; Koch, K P
2004-04-01
Neural prostheses partially restore body functions by technical nerve excitation after trauma or neurological diseases. External devices and implants have been developed since the early 1960s for many applications. Several systems have reached nowadays clinical practice: Cochlea implants help the deaf to hear, micturition is induced by bladder stimulators in paralyzed persons and deep brain stimulation helps patients with Parkinson's disease to participate in daily life again. So far, clinical neural prostheses are fabricated with means of precision mechanics. Since microsystem technology opens the opportunity to design and develop complex systems with a high number of electrodes to interface with the nervous systems, the opportunity for selective stimulation and complex implant scenarios seems to be feasible in the near future. The potentials and limitations with regard to biomedical microdevices are introduced and discussed in this paper. Target specifications are derived from existing implants and are discussed on selected applications that has been investigated in experimental research: a micromachined implant to interface a nerve stump with a sieve electrode, cuff electrodes with integrated electronics, and an epiretinal vision prosthesis.
Fritz, M; Rinaldi, G
2008-01-01
Systolic blood pressure (SBP) is still measured in rats by the tail-cuff method, allowing readings when pulse/flow disappears during cuff inflation and reappears during deflation, separated by a compression interval. Although cuff deflation is habitually used to estimate SBP, we found cuff deflation-cuff inflation pressure to be usually negative, indicating that cuff deflation pressure < cuff inflation pressure. SBP was measured in 226 male Wistar and SHR utilizing compression intervals of different durations, and also pharmacological interventions intended to modulate the cuff deflation-cuff inflation cycle. Direct, simultaneous intravascular measurements were also performed in some animals. With compression interval congruent with 15 s, cuff deflation-cuff inflation was--6 +/- 0.6 mmHg in 73 Wistar and--6 +/- 1.4 mmHg in 51 SHR. Lengthening compression interval up to 4 min increased cuff deflation-cuff inflation pressure significantly to--27 +/- 3 mmHg in Wistar and to - 31 +/- 5 mmHg in SHR, suggesting accumulation of a vasodilating mediator. This increase of cuff deflation-cuff inflation pressure was prevented by papaverine (totally in Wistar, partially in SHR), indicating its dependence on vasodilatory capacity. Adrenergic blockade decreased cuff deflation-cuff inflation pressure to--13 +/- 5 mmHg (P < 0.05) in SHR, but had no effect in Wistar rats. Injection of L-NAME decreased cuff deflation-cuff inflation pressure to--5 +/- 2 mmHg (P < 0.05) in Wistar rats but was ineffective in SHR. Simultaneous measurements by tail-cuff method and carotid cannulation revealed that the cuff inflation most accurately estimated the intravascular SBP. 1) Cuff inflation measurements should be considered representative of SBP, as cuff deflation can underestimate SBP depending on compression interval duration, 2) nitric oxide accumulation due to flow deprivation is the main cause of SBP underestimation by cuff deflation in Wistar, and 3) in SHR, nitric oxide effects were minimal, and sympathetic activation plus physical factors seemed to predominate in the determining the outcome of measurements.
NASA Astrophysics Data System (ADS)
Letelier, Patricio S.
1999-04-01
We give a physical interpretation to the multi-polar Erez-Rozen-Quevedo solution of the Einstein equations in terms of bars. We find that each multi-pole corresponds to the Newtonian potential of a bar with linear density proportional to a Legendre polynomial. We use this fact to find an integral representation of the 0264-9381/16/4/010/img1 function. These integral representations are used in the context of the inverse scattering method to find solutions associated with one or more rotating bodies each with their own multi-polar structure.
Two-way communication for programming and measurement in a miniature implantable stimulator.
Thil, M A; Gérard, B; Jarvis, J C; Delbeke, J
2005-07-01
Implantable stimulators are needed for chronic electrical stimulation of nerves and muscles in experimental studies. The device described exploits the versatility of current microcontrollers for stimulation and communication in a miniature implant. Their standard outputs can provide the required selectable constant-current sources. In this device, pre-programmed stimulation paradigms were selected by transcutaneous light pulses. The potential of a programmable integrated circuit (PIC) was thus exploited. Implantable devices must be biocompatible. A novel encapsulation method that require no specialised equipment and that used two classical encapsulants, silicone and Teflon was developed. It was tested for implantation periods of up to four weeks. A novel way to estimate electrode impedance in awake animals is also presented. It was thus possible to follow the evolution of the nerve-electrode interface and, if necessary, to adjust the stimulation parameters. In practice, the electrode voltage at the end of a known constant-current pulse was measured by the PIC. The binary coded value was then indicated to the user as a series of muscle twitches that represented the binary value of the impedance measurement. This neurostimulator has been successfully tested in vitro and in vivo. Thresholds and impedance values were chronically monitored following implantation of a self-sizing spiral cuff electrode. Impedance variations in the first weeks could reflect morphological changes usually observed after the implantation of such electrodes.
Hedberg, Pia; Eklund, Carolina; Högqvist, Sandra
2015-06-01
The most common complication due to intubation is a high cuff pressure. A high cuff pressure can cause postanesthetic tracheal mucosal injuries in patients undergoing surgery. The aim of this cross-sectional study was to describe whether anesthetic nurses and anesthesiologists identified a very high cuff pressure by manual palpation of the external cuff balloon on an endotracheal tube. An airway device was intubated with an endotracheal tube cuffed to 95 cm H2O. Each participant palpated the external cuff balloon and then filled out a questionnaire, including estimation of the cuff pressure and user frequency of the cuff pressure manometer. The results showed that 89.1% estimated that the cuff pressure was high. Among the participants who rated the cuff pressure as high, 44.8% rated the pressure as quite high and 60.6% rated the pressure as very high. There was no significant relationship between profession and skill in identifying a very high cuff pressure (P = .843) or between work experience and skill in terms of identifying a very high cuff pressure (P = .816). These findings indicate that 10% of patients are at risk of tracheal erosion because of a high cuff pressure.
Evaluation of focused multipolar stimulation for cochlear implants in acutely deafened cats
NASA Astrophysics Data System (ADS)
George, Shefin S.; Wise, Andrew K.; Shivdasani, Mohit N.; Shepherd, Robert K.; Fallon, James B.
2014-12-01
Objective. The conductive nature of the fluids and tissues of the cochlea can lead to broad activation of spiral ganglion neurons using contemporary cochlear implant stimulation configurations such as monopolar (MP) stimulation. The relatively poor spatial selectivity is thought to limit implant performance, particularly in noisy environments. Several current focusing techniques have been proposed to reduce the spread of activation with the aim towards achieving improved clinical performance. Approach. The present research evaluated the efficacy of focused multipolar (FMP) stimulation, a relatively new focusing technique in the cochlea, and compared its efficacy to both MP stimulation and tripolar (TP) stimulation. The spread of neural activity across the inferior colliculus (IC), measured by recording the spatial tuning curve, was used as a measure of spatial selectivity. Adult cats (n = 6) were acutely deafened and implanted with an intracochlear electrode array before multi-unit responses were recorded across the cochleotopic gradient of the contralateral IC. Recordings were made in response to acoustic and electrical stimulation using the MP, TP and FMP configurations. Main results. FMP and TP stimulation resulted in greater spatial selectivity than MP stimulation. However, thresholds were significantly higher (p < 0.001) for FMP and TP stimulation compared to MP stimulation. There were no differences found in spatial selectivity and threshold between FMP and TP stimulation. Significance. The greater spatial selectivity of FMP and TP stimulation would be expected to result in improved clinical performance. However, further research will be required to demonstrate the efficacy of these modes of stimulation after longer durations of deafness.
Passive contribution of the rotator cuff to abduction and joint stability.
Tétreault, Patrice; Levasseur, Annie; Lin, Jenny C; de Guise, Jacques; Nuño, Natalia; Hagemeister, Nicola
2011-11-01
The purpose of this study is to compare shoulder joint biomechanics during abduction with and without intact non-functioning rotator cuff tissue. A cadaver model was devised to simulate the clinical findings seen in patients with a massive cuff tear. Eight full upper limb shoulder specimens were studied. Initially, the rotator cuff tendons were left intact, representing a non-functional rotator cuff, as seen in suprascapular nerve paralysis or in cuff repair with a patch. Subsequently, a massive rotator cuff tear was re-created. Three-dimensional kinematics and force requirements for shoulder abduction were analyzed for each condition using ten abduction cycles in the plane of the scapula. Mediolateral displacements of the glenohumeral rotation center (GHRC) during abduction with an intact non-functioning cuff were minimal, but massive cuff tear resulted in significant lateral displacement of the GHRC (p < 0.013). Similarly, massive cuff tear caused increased superior migration of the GHRC during abduction compared with intact non-functional cuff (p < 0.01). From 5 to 30° of abduction, force requirements were significantly less with an intact non-functioning cuff than with massive cuff tear (p < 0.009). During abduction, an intact but non-functioning rotator cuff resulted in decreased GHRC displacement in two axes as well as lowered the force requirement for abduction from 5 to 30° as compared with the results following a massive rotator cuff tear. This provides insight into the potential biomechanical effect of repairing massive rotator cuff tears with a biological or synthetic "patch," which is a new treatment for massive cuff tear.
Linder, Brian J; Viers, Boyd R; Ziegelmann, Matthew J; Rivera, Marcelino E; Elliott, Daniel S
2017-01-01
To compare outcomes for single urethral cuff downsizing versus tandem cuff placement during artificial urinary sphincter (AUS) revision for urethral atrophy. We identified 1778 AUS surgeries performed at our institution from 1990-2014. Of these, 406 were first AUS revisions, including 69 revisions for urethral atrophy. Multiple clinical and surgical variables were evaluated for potential association with device outcomes following revision, including surgical revision strategy (downsizing a single urethral cuff versus placing tandem urethral cuffs). Of the 69 revision surgeries for urethral atrophy at our institution, 56 (82%) were tandem cuff placements, 12 (18%) were single cuff downsizings and one was relocation of a single cuff. When comparing tandem cuff placements and single cuff downsizings, the cohorts were similar with regard to age (p=0.98), body-mass index (p=0.95), prior pelvic radiation exposure (p=0.73) and length of follow-up (p=0.12). Notably, there was no difference in 3-year overall device survival compared between single cuff and tandem cuff revisions (60% versus 76%, p=0.94). Likewise, no significant difference was identified for tandem cuff placement (ref. single cuff) when evaluating the risk of any tertiary surgery (HR 0.95, 95% CI 0.32-4.12, p=0.94) or urethral erosion/device infection following revision (HR 0.79, 95% CI 0.20-5.22, p=0.77). There was no significant difference in overall device survival in patients undergoing single cuff downsizing or tandem cuff placement during AUS revision for urethral atrophy. Copyright® by the International Brazilian Journal of Urology.
Ayers, Christopher A; Fisher, Lee E; Gaunt, Robert A; Weber, Douglas J
2016-07-01
Patterned microstimulation of the dorsal root ganglion (DRG) has been proposed as a method for delivering tactile and proprioceptive feedback to amputees. Previous studies demonstrated that large- and medium-diameter afferent neurons could be recruited separately, even several months after implantation. However, those studies did not examine the anatomical localization of sensory fibers recruited by microstimulation in the DRG. Achieving precise recruitment with respect to both modality and receptive field locations will likely be crucial to create a viable sensory neuroprosthesis. In this study, penetrating microelectrode arrays were implanted in the L5, L6, and L7 DRG of four isoflurane-anesthetized cats instrumented with nerve cuff electrodes around the proximal and distal branches of the sciatic and femoral nerves. A binary search was used to find the recruitment threshold for evoking a response in each nerve cuff. The selectivity of DRG stimulation was characterized by the ability to recruit individual distal branches to the exclusion of all others at threshold; 84.7% (n = 201) of the stimulation electrodes recruited a single nerve branch, with 9 of the 15 instrumented nerves recruited selectively. The median stimulation threshold was 0.68 nC/phase, and the median dynamic range (increase in charge while stimulation remained selective) was 0.36 nC/phase. These results demonstrate the ability of DRG microstimulation to achieve selective recruitment of the major nerve branches of the hindlimb, suggesting that this approach could be used to drive sensory input from localized regions of the limb. This sensory input might be useful for restoring tactile and proprioceptive feedback to a lower-limb amputee. Copyright © 2016 the American Physiological Society.
Levine, Yaakov A.; Koopman, Frieda A.; Faltys, Michael; Caravaca, April; Bendele, Alison; Zitnik, Ralph; Vervoordeldonk, Margriet J.; Tak, Paul Peter
2014-01-01
Introduction The inflammatory reflex is a physiological mechanism through which the nervous system maintains immunologic homeostasis by modulating innate and adaptive immunity. We postulated that the reflex might be harnessed therapeutically to reduce pathological levels of inflammation in rheumatoid arthritis by activating its prototypical efferent arm, termed the cholinergic anti-inflammatory pathway. To explore this, we determined whether electrical neurostimulation of the cholinergic anti-inflammatory pathway reduced disease severity in the collagen-induced arthritis model. Methods Rats implanted with vagus nerve cuff electrodes had collagen-induced arthritis induced and were followed for 15 days. Animals underwent active or sham electrical stimulation once daily from day 9 through the conclusion of the study. Joint swelling, histology, and levels of cytokines and bone metabolism mediators were assessed. Results Compared with sham treatment, active neurostimulation of the cholinergic anti-inflammatory pathway resulted in a 52% reduction in ankle diameter (p = 0.02), a 57% reduction in ankle diameter (area under curve; p = 0.02) and 46% reduction overall histological arthritis score (p = 0.01) with significant improvements in inflammation, pannus formation, cartilage destruction, and bone erosion (p = 0.02), accompanied by numerical reductions in systemic cytokine levels, not reaching statistical significance. Bone erosion improvement was associated with a decrease in serum levels of receptor activator of NF-κB ligand (RANKL) from 132±13 to 6±2 pg/mL (mean±SEM, p = 0.01). Conclusions The severity of collagen-induced arthritis is reduced by neurostimulation of the cholinergic anti-inflammatory pathway delivered using an implanted electrical vagus nerve stimulation cuff electrode, and supports the rationale for testing this approach in human inflammatory disorders. PMID:25110981
Saline-filled cuffs help prevent laser-induced polyvinylchloride endotracheal tube fires.
Sosis, M B; Dillon, F X
1991-02-01
To determine whether the filling of tracheal tube cuffs with saline would decrease their combustibility during laser surgery, 20 polyvinylchloride tracheal tubes were studied. The cuffed end of each tracheal tube was inserted into the neck of an empty flask, and the tube and flask were flushed with oxygen for 5 min before cuff inflation. Ten tracheal tubes had their cuffs inflated with air, and 10 were inflated with saline. A Lasersonics LS880 CO2 laser, set to 5 W for five of each of the two types of filled cuffs and to 40 W for the other pair of five tubes, was fired continuously at the cuffs for up to 1 min. No combustion occurred at the 5-W setting. The times to cuff perforation when the laser was set at 5 W were (mean +/- SD) 1.00 +/- 0.83 and 4.21 +/- 3.91 s for the air- and saline-filled cuffs, respectively, a difference that was not statistically significant. The time to deflation of the saline-filled cuff (104.6 +/- 67.5 s) was, however, significantly longer than that of the air-filled cuff (2.59 +/- 1.97 s). When the tracheal tube cuffs were exposed to 40-W laser radiation, the cuff and adjacent tube shaft ignited in all cases when the cuffs were inflated with air, but only in one of five cases when the cuffs were filled with saline (P less than 0.05). The filling of tracheal tube cuffs with saline provides simple, moderately effective partial protection of the cuff of endotracheal tubes during CO2 laser airway surgery.
[Rotator cuff tear athropathy prevalence].
Guerra-Soriano, F; Encalada-Díaz, M I; Ruiz-Suárez, M; Valero-González, F S
2017-01-01
Glenohumeral arthritis secondary to massive rotator cuff tear presents with a superior displacement and femoralization of the humeral head with coracoacromial arch acetabularization. The purpose of this study was to establish prevalence of rotator cuff tear artropathy (CTA) at our institution. Four hundred electronic records were reviewed from which we identified 136 patients with rotator cuff tears. A second group was composed with patients with massive cuff tears that were analized and staged by the Seebauer cuff tear arthropathy classification. Thirty four patients with massive rotator cuff tears were identified, 8 male and 26 female (age 60.1 ± 10.26 years). Massive rotator cuff tear prevalence was 25%. CTA prevalence found in the rotator cuff group was 19 and 76% in the massive cuff tears group. Patients were staged according to the classification with 32% in stage 1a, 11% 1b, 32% 2a and 0% 2b. CTA prevalence in patients with rotator cuff tears and massive cuff tears is higher than the one reported in American population. We consider that a revision of the Seebauer classification to be appropriate to determine its reliability.
Evaluation of cartilage degeneration in a rat model of rotator cuff tear arthropathy
Kramer, Erik J.; Bodendorfer, Blake M.; Laron, Dominique; Wong, Jason; Kim, Hubert T.; Liu, Xuhui; Feeley, Brian T.
2013-01-01
Introduction Rotator cuff tears are the most common injury seen by shoulder surgeons. Many late stage rotator cuff tear patients develop glenohumeral osteoarthritis as a result of torn cuff tendons, termed cuff tear arthropathy. However, the mechanisms of cuff tear arthropathy have not been fully established. It has been hypothesized that a combination of synovial and mechanical factors contribute equally to the development of cuff tear arthropathy. The goal of this study was to assess the utility of this model in investigating cuff-tear arthropathy. Methods We utilized a rat model which accurately reflects rotator cuff muscle degradation after massive rotator cuff tears through either infraspinatus and supraspinatus tenotomy or suprascapular nerve transection. Using a Modified-Mankin Scoring System (MMS), we found significant glenohumeral cartilage damage following both rotator cuff tenotomy and suprascapular nerve transection after only 12 weeks. Results Cartilage degeneration was similar between groups, and was present on both the humeral head and the glenoid. Denervation of the supraspinatus and infraspinatus muscles without opening the joint capsule caused cartilage degeneration similar to that found in the tendon transection group. Conclusions These results suggest that altered mechanical loading after rotator cuff tears is the primary factor in cartilage degeneration after rotator cuff tears. Clinically, understanding the process of cartilage degeneration after rotator cuff injury will help guide treatment decisions in the setting of rotator cuff tears. Level of evidence Basic Science Study, Animal Model PMID:23664745
Automated control of endotracheal tube cuff pressure during simulated flight.
Blakeman, Thomas; Rodriquez, Dario; Woods, James; Cox, Daniel; Elterman, Joel; Branson, Richard
2016-11-01
Successful mechanical ventilation requires that the airway be controlled by an endotracheal tube (ETT) with an inflatable cuff to seal the airway. Aeromedical evacuation represents a unique challenge in which to manage ETT cuffs. We evaluated three methods of automatic ETT cuff pressure adjustment during changes in altitude in an altitude chamber. Size 7.5 and 8.0 mm ETTs that are currently included in the Critical Care Air Transport Team allowance standard were used for the evaluation. Three automatic cuff pressure controllers-Intellicuff, Hamilton Medical; Pyton, ARM Medical; and Cuff Sentry, Outcome Solutions-were used to manage cuff pressures. The fourth group had cuff pressure set at sea level without further adjustment. Each ETT was inserted into a tracheal model and taken to 8,000 feet and then to 16,000 feet at 2,500 ft/min. Baseline cuff pressure at sea level was approximately 25 cm H2O. Mean cuff pressure at both altitudes with both size ETTs was as follows: Control arm, 141 ± 64 cm H2O; Pyton, 25 ± 0.8 cm H2O; Cuff Sentry, 22 ± 0.3 cm H2O; and Intellicuff, 29 ± 6.6 cm H2O. The mean time that cuff pressure was >30 cm H2O using Intellicuff at both altitudes was 2.8 ± 0.8 minutes. Pressure differences from baseline in the control arm and with Intellicuff were statistically significant. Cuff pressure with the Cuff Sentry tended to be lower than indicated on the device. Mean cuff pressures were within the recommended range with all three devices. Intellicuff had difficulty regulating the cuff pressure initially with increases in altitude but was able to reduce the pressure to a safe level during the stabilization period at each altitude. The Pyton and Cuff Sentry allowed the least variation in pressure throughout the evaluation, although the Cuff Sentry set pressure was less than the actual pressure. Therapeutic study, level V.
Measurements of multipolarities in 225Ra
NASA Astrophysics Data System (ADS)
Andersen, E.; Borge, M. J. G.; Burke, D. G.; Gietz, H.; Hill, P.; Kaffrell, N.; Kurcewicz, W.; Løvhøiden, G.; Mattsson, S.; Naumann, R. A.; Nybø, K.; Nyman, G.; Thorsteinsen, T. F.; Isolde Collaboration
1989-01-01
Multipolarities of 45 transitions in 225Ra have been established by investigating the radiations associated with the β - decay of 225Fr. The study includes β -, e - and γ-singles spectra, e -γ- and γγ-coincidence measurements. The conversion electrons were measured with a mini-orange electron spectrometer, and the γ-spectra with Ge detectors. The multipolarities obtained from the measured conversion coefficients support the assignments of spin-parity doublets thus giving evidence for a stable octupole deformation of this nucleus. The negative parity of the 394.2 keV level established in the present work indicates that this level is a candidate for the parity-doublet partner of the {5}/{2}+ state at 236.3 keV.
2017-01-31
AFRL-SA-WP-SR-2017-0004 Correlation Between Endotracheal Tube Cuff Pressure and Tracheal Wall Pressure Using Air- and Saline -Filled...Correlation Between Endotracheal Tube Cuff Pressure and Tracheal Wall Pressure Using Air- and Saline -Filled Cuffs 5a. CONTRACT NUMBER FA8650-14...descending from altitude. When using saline in the ETT cuff, TW pressure differences with the 7.5 high-volume, low-pressure cuff and 8.0 TaperGuard
Experimental and theoretical charge density studies at subatomic resolution.
Fischer, A; Tiana, D; Scherer, W; Batke, K; Eickerling, G; Svendsen, H; Bindzus, N; Iversen, B B
2011-11-17
Analysis of accurate experimental and theoretical structure factors of diamond and silicon reveals that the contraction of the core shell due to covalent bond formation causes significant perturbations of the total charge density that cannot be ignored in precise charge density studies. We outline that the nature and origin of core contraction/expansion and core polarization phenomena can be analyzed by experimental studies employing an extended Hansen-Coppens multipolar model. Omission or insufficient treatment of these subatomic charge density phenomena might yield erroneous thermal displacement parameters and high residual densities in multipolar refinements. Our detailed studies therefore suggest that the refinement of contraction/expansion and population parameters of all atomic shells is essential to the precise reconstruction of electron density distributions by a multipolar model. Furthermore, our results imply that also the polarization of the inner shells needs to be adopted, especially in cases where second row or even heavier elements are involved in covalent bonding. These theoretical studies are supported by direct multipolar refinements of X-ray powder diffraction data of diamond obtained from a third-generation synchrotron-radiation source (SPring-8, BL02B2).
On macromolecular refinement at subatomic resolution with interatomic scatterers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Afonine, Pavel V., E-mail: pafonine@lbl.gov; Grosse-Kunstleve, Ralf W.; Adams, Paul D.
2007-11-01
Modelling deformation electron density using interatomic scatters is simpler than multipolar methods, produces comparable results at subatomic resolution and can easily be applied to macromolecules. A study of the accurate electron-density distribution in molecular crystals at subatomic resolution (better than ∼1.0 Å) requires more detailed models than those based on independent spherical atoms. A tool that is conventionally used in small-molecule crystallography is the multipolar model. Even at upper resolution limits of 0.8–1.0 Å, the number of experimental data is insufficient for full multipolar model refinement. As an alternative, a simpler model composed of conventional independent spherical atoms augmented bymore » additional scatterers to model bonding effects has been proposed. Refinement of these mixed models for several benchmark data sets gave results that were comparable in quality with the results of multipolar refinement and superior to those for conventional models. Applications to several data sets of both small molecules and macromolecules are shown. These refinements were performed using the general-purpose macromolecular refinement module phenix.refine of the PHENIX package.« less
Komasawa, Nobuyasu; Mihara, Ryosuke; Imagawa, Kentaro; Hattori, Kazuo; Minami, Toshiaki
2015-01-01
The present study compared changes in cuff pressure by head and neck position between high-volume low-pressure (HVLP) and taper-shaped (taper) cuffs in a prospective randomized clinical trial. Methods. Forty patients were intubated using tracheal tubes with either HVLP (n = 20; HVLP group) or taper-shaped (n = 20; Taper group) cuffs. Initial cuff pressure was adjusted to 15, 20, or 25 cmH2O in the neutral position. Cuff pressure was evaluated after changing the head and neck positions to flexion, extension, and rotation. Results. Cuff pressure significantly increased with flexion in both HVLP and Taper groups at all initial cuff pressures. It significantly increased with extension in the HVLP group, but not in the Taper group. Cuff pressure did not significantly differ with rotation in either group and was significantly smaller in the Taper group during flexion and extension than in the HVLP group, regardless of initial cuff pressure. Conclusion. Cuff pressure changes with head and neck flexion and extension were smaller in the Taper group than in the HVLP group. Our results highlight the potential for taper cuffs to prevent excessive cuff pressure increases with positional changes in the head and neck. This trial is registered with UMIN000016119. PMID:26509152
The minimal leak test technique for endotracheal cuff maintenance.
Harvie, D A; Darvall, J N; Dodd, M; De La Cruz, A; Tacey, M; D'Costa, R L; Ward, D
2016-09-01
Endotracheal tube (ETT) cuff pressure management is an essential part of airway management in intubated and mechanically ventilated patients. Both under- and over-inflation of the ETT cuff can lead to patient complications, with an ideal pressure range of 20-30 cmH 2 O defined. A range of techniques are employed to ensure adequate ETT cuff inflation, with little comparative data. We performed an observational cross-sectional study in a tertiary metropolitan ICU, assessing the relationship between the minimal leak test and cuff manometry. Forty-five mechanically ventilated patients, over a three-month period, had ETT cuff manometry performed at the same time as their routine cuff maintenance (minimal leak test). Bedside nurse measurements were compared with investigator measurements. At the endpoint of cuff inflation, 20 of 45 patients (44%) had cuff pressures between 20 and 30 cmH 2 O; 11 of 45 patients (24%) had cuff pressures <20 cmH 2 O; 14 of 45 patients (31%) had cuff pressures ≥30 cmH 2 O. Univariate analysis demonstrated an association between both patient obesity and female gender requiring less ETT cuff volume ( P =0.008 and P <0.001 respectively), though this association was lost on multivariate analysis. No association was demonstrated between any measured variables and cuff pressures. Inter-operator reliability in performing the minimal leak test showed no evidence of bias between nurse and investigators (Pearson coefficient = 0.897). We conclude the minimal leak test for maintenance of ETT cuffs leads to both over- and under-inflation, and alternative techniques, such as cuff manometry, should be employed.
p53 Dependent Centrosome Clustering Prevents Multipolar Mitosis in Tetraploid Cells
Yi, Qiyi; Zhao, Xiaoyu; Huang, Yun; Ma, Tieliang; Zhang, Yingyin; Hou, Heli; Cooke, Howard J.; Yang, Da-Qing; Wu, Mian; Shi, Qinghua
2011-01-01
Background p53 abnormality and aneuploidy often coexist in human tumors, and tetraploidy is considered as an intermediate between normal diploidy and aneuploidy. The purpose of this study was to investigate whether and how p53 influences the transformation from tetraploidy to aneuploidy. Principal Findings Live cell imaging was performed to determine the fates and mitotic behaviors of several human and mouse tetraploid cells with different p53 status, and centrosome and spindle immunostaining was used to investigate centrosome behaviors. We found that p53 dominant-negative mutation, point mutation, or knockout led to a 2∼ 33-fold increase of multipolar mitosis in N/TERT1, 3T3 and mouse embryonic fibroblasts (MEFs), while mitotic entry and cell death were not significantly affected. In p53-/- tetraploid MEFs, the ability of centrosome clustering was compromised, while centrosome inactivation was not affected. Suppression of RhoA/ROCK activity by specific inhibitors in p53-/- tetraploid MEFs enhanced centrosome clustering, decreased multipolar mitosis from 38% to 20% and 16% for RhoA and ROCK, respectively, while expression of constitutively active RhoA in p53+/+ tetraploid 3T3 cells increased the frequency of multipolar mitosis from 15% to 35%. Conclusions p53 could not prevent tetraploid cells entering mitosis or induce tetraploid cell death. However, p53 abnormality impaired centrosome clustering and lead to multipolar mitosis in tetraploid cells by modulating the RhoA/ROCK signaling pathway. PMID:22076149
Composition of Muscle Fiber Types in Rat Rotator Cuff Muscles.
Rui, Yongjun; Pan, Feng; Mi, Jingyi
2016-10-01
The rat is a suitable model to study human rotator cuff pathology owing to the similarities in morphological anatomy structure. However, few studies have reported the composition muscle fiber types of rotator cuff muscles in the rat. In this study, the myosin heavy chain (MyHC) isoforms were stained by immunofluorescence to show the muscle fiber types composition and distribution in rotator cuff muscles of the rat. It was found that rotator cuff muscles in the rat were of mixed fiber type composition. The majority of rotator cuff fibers labeled positively for MyHCII. Moreover, the rat rotator cuff muscles contained hybrid fibers. So, compared with human rotator cuff muscles composed partly of slow-twitch fibers, the majority of fast-twitch fibers in rat rotator cuff muscles should be considered when the rat model study focus on the pathological process of rotator cuff muscles after injury. Gaining greater insight into muscle fiber types in rotator cuff muscles of the rat may contribute to elucidate the mechanism of pathological change in rotator cuff muscles-related diseases. Anat Rec, 299:1397-1401, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
A review of invasive and non-invasive sensory feedback in upper limb prostheses.
Svensson, Pamela; Wijk, Ulrika; Björkman, Anders; Antfolk, Christian
2017-06-01
The constant challenge to restore sensory feedback in prosthetic hands has provided several research solutions, but virtually none has reached clinical fruition. A prosthetic hand with sensory feedback that closely imitates an intact hand and provides a natural feeling may induce the prosthetic hand to be included in the body image and also reinforces the control of the prosthesis. Areas covered: This review presents non-invasive sensory feedback systems such as mechanotactile, vibrotactile, electrotactile and combinational systems which combine the modalities; multi-haptic feedback. Invasive sensory feedback has been tried less, because of the inherent risk, but it has successfully shown to restore some afferent channels. In this review, invasive methods are also discussed, both extraneural and intraneural electrodes, such as cuff electrodes and transverse intrafascicular multichannel electrodes. The focus of the review is on non-invasive methods of providing sensory feedback to upper-limb amputees. Expert commentary: Invoking embodiment has shown to be of importance for the control of prosthesis and acceptance by the prosthetic wearers. It is a challenge to provide conscious feedback to cover the lost sensibility of a hand, not be overwhelming and confusing for the user, and to integrate technology within the constraint of a wearable prosthesis.
Sommer, C M; Lemm, G; Hohenstein, E; Bellemann, N; Stampfl, U; Goezen, A S; Rassweiler, J; Kauczor, H U; Radeleff, B A; Pereira, P L
2013-06-01
This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. We included 22 consecutive patients (3 women; age 74.2 ± 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 ± 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 ± 13.6 min and 43.7 ± 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 ± 8.8 months, local recurrence-free survival was 14.4 ± 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 ± 16.6 ml/min/1.73 m(2) before RF ablation vs. 47.2 ± 11.9 ml/min/1.73 m(2) after RF ablation; not significant). CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.
New-generation radiofrequency technology.
Krueger, Nils; Sadick, Neil S
2013-01-01
Radiofrequency (RF) technology has become a standard treatment in aesthetic medicine with many indications due to its versatility, efficacy, and safety. It is used worldwide for cellulite reduction; acne scar revision; and treatment of hypertrophic scars and keloids, rosacea, and inflammatory acne in all skin types. However, the most common indication for RF technology is the nonablative tightening of tissue to improve skin laxity and reduce wrinkles. Radiofrequency devices are classified as unipolar, bipolar, or multipolar depending on the number of electrodes used. Additional modalities include fractional RF; sublative RF; phase-controlled RF; and combination RF therapies that apply light, massage, or pulsed electromagnetic fields (PEMFs). This article reviews studies and case series on these devices. Radiofrequency technology for aesthetic medicine has seen rapid advancements since it was used for skin tightening in 2003. Future developments will continue to keep RF technology at the forefront of the dermatologist's armamentarium for skin tightening and rejuvenation.
An in vitro comparison of tracheostomy tube cuffs
Maguire, Seamus; Haury, Frances; Jew, Korinne
2015-01-01
Introduction The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT]) with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force. Methods Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O), instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site. Results The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05). The taper-shaped cuff also demonstrated a more even, lower pressure distribution along the lateral wall of the model trachea. The average air and fluid seal performance with the taper-shaped cuff was significantly improved, when compared to the cylindrical-shaped cuff, for each tube size tested (P<0.05). The insertion force for the taper-shaped cuff was ~40% less than that for the cylindrical-shaped cuff. Conclusion In a model trachea, the Shiley™ Flexible Adult tracheostomy tube with TaperGuard™ cuff, when compared to the Shiley™ Disposable Inner Cannula Tracheostomy tube with cylindrical cuff, exerted a lower average lateral wall pressure and a more evenly distributed pressure. In addition, it provided more effective fluid and air seals and required less force to insert. PMID:25960679
Charmoy, Alexia; Würzner, Grégoire; Ruffieux, Christiane; Hasler, Christopher; Cachat, François; Waeber, Bernard; Burnier, Michel
2007-10-01
Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (P<0.01), and at both levels of cuff inflation. The blood pressure response to cuff inflation was independent of baseline blood pressure. The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.
Development of Skylab medical equipment and flight preparations
NASA Technical Reports Server (NTRS)
Johnston, R. S.; Stonesifer, J. C.; Hawkins, W. R.
1975-01-01
The major medical systems in the Skylab orbital workshop are described. They comprise the food system, the waste management system, operational bioinstrumentation, personal hygiene, gas sampling, an inflight medical support system, and a cardiovascular counterpressure garment. Life sciences experiments carried out aboard Skylab are also reviewed; these include an ergometer and metabolic analyzer, a lower-body negative pressure device, an electrode harness and body temperature probe, a blood pressure cuff, a leg volume measuring band, sleep studies, a body-mass measuring device, a rotating litter chair, a blood sample processor, and small-mass measuring apparatus. All performance requirements were met with the equipment, and no failures were encountered.
Almarakbi, Waleed A; Kaki, Abdullah M
2014-07-01
The main function of an endotracheal tube (ETT) cuff is to prevent aspiration. High cuff pressure is usually associated with postoperative complications. We tried to compare cuff inflation guided by pressure volume loop closure (PV-L) with those by just to seal technique (JS) and assess the postoperative incidence of sore throat, cough and hoarseness. In a prospective, randomized clinical trial, 100 patients' tracheas were intubated. In the first group (n = 50), ETT cuff inflation was guided by PV-L, while in the second group (n. = 50) the ETT cuff was inflated using the JS technique. Intracuff pressures and volumes were measured. The incidence of postoperative cuff-related complications was reported. Demographic data and durations of intubation were comparable between the groups. The use of PV-L was associated with a lesser amount of intracuff air [4.05 (3.7-4.5) vs 5 (4.8-5.5), P < 0.001] and lower cuff pressure than those in the JS group [18.25 (18-19) vs 33 (32-35), P ≤ 0.001]. The incidence of postextubation cuff-related complications was significantly less frequent among the PV-L group patients as compared with the JS group patients (P ≤ 0.009), except for hoarseness of voice, which was less frequent among the PV-L group, but not statistically significant (P ≤ 0.065). Multiple regression models for prediction of intra-cuff pressure after intubation and before extubation revealed a statistically significant association with the technique used for cuff inflation (P < 0.0001). The study confirms that PV-L-guided ETT cuff inflation is an effective way to seal the airway and associates with a lower ETT cuff pressure and lower incidence of cuff-related complications.
Comparison of outcomes after single or DOUBLE-CUFF artificial urinary sphincter insertion.
O'Connor, R Corey; Gerber, Glenn S; Avila, Desiderio; Chen, Andrew A; Bales, Gregory T
2003-10-01
To assess the effectiveness and complications associated with single and double-cuff artificial urinary sphincter (AUS) implantation for postprostatectomy stress urinary incontinence. A retrospective study of 56 men with postprostatectomy stress urinary incontinence who underwent either single (28 patients) or double (28 patients) cuff AUS placement was performed. Patients in each cohort were matched on the basis of preoperative pad use, risk factors for complications, and age. Patient selection was blinded relative to outcome. Continence, quality of life, and complications were assessed using the Incontinence Impact Questionnaire Short Form (IIQ-7), postoperative pad use, and chart review. The mean age was 67 years for each group. Daily pad use decreased from 7.7 to 1.1 in patients treated with a single-cuff AUS and from 7.8 to 0.7 in patients with a double-cuff AUS (P = 0.25). Complete continence (0 pads daily) was reported in 3 (11%) of 28 men with single-cuff and 12 (43%) of 28 men with double-cuff sphincters (P = 0.008). The IIQ-7 scores improved from 14.8 to 3.1 after single-cuff placement and from 16.3 to 2.5 after double-cuff placement (P = 0.03). With an average follow-up of 41.3 and 21.2 months for the single and double-cuff cohorts, respectively, five complications were reported in the single-cuff recipients and four in the double-cuff patients. A significantly greater rate of complete continence and improvement in the IIQ-7 were seen in men with double-cuff AUS compared with single-cuff devices. Additional study is needed to confirm the relative advantages of double-cuff insertion.
Strategies for Business Schools in a Multi-Polar World
ERIC Educational Resources Information Center
Dameron, Stephanie; Durand, Thomas
2013-01-01
Purpose: The purpose of this paper is to examine the contours of the emerging business education and institutions in a multi-polar world and to identify the causes of the strategic convergence of management education, to explore the limitations of the dominant models of management education and to propose a range of strategic alternatives for…
Makhni, Eric C; Swart, Eric; Steinhaus, Michael E; Mather, Richard C; Levine, William N; Bach, Bernard R; Romeo, Anthony A; Verma, Nikhil N
2016-09-01
To compare the cost-effectiveness within the United States health care system of arthroscopic rotator cuff repair versus reverse total shoulder arthroplasty in patients with symptomatic large and massive rotator cuff tears without cuff-tear arthropathy. An expected-value decision analysis was constructed comparing the costs and outcomes of patients undergoing arthroscopic rotator cuff repair and reverse total shoulder arthroplasty for large and massive rotator cuff tears (and excluding cases of cuff-tear arthropathy). Comprehensive literature search provided input data to extrapolate costs and health utility states for these outcomes. The primary outcome assessed was that of incremental cost-effectiveness ratio (ICER) of reverse total shoulder arthroplasty versus rotator cuff repair. For the base case, both arthroscopic rotator cuff repair and reverse total shoulder were superior to nonoperative care, with an ICER of $15,500/quality-adjusted life year (QALY) and $37,400/QALY, respectively. Arthroscopic rotator cuff repair was dominant over primary reverse total shoulder arthroplasty, with lower costs and slightly improved clinical outcomes. Arthroscopic rotator cuff repair was the preferred strategy as long as the lifetime progression rate from retear to end-stage cuff-tear arthropathy was less than 89%. However, when the model was modified to account for worse outcomes when reverse shoulder arthroplasty was performed after a failed attempted rotator cuff repair, primary reverse total shoulder had superior outcomes with an ICER of $90,000/QALY. Arthroscopic rotator cuff repair-despite high rates of tendon retearing-for patients with large and massive rotator cuff tears may be a more cost-effective initial treatment strategy when compared with primary reverse total shoulder arthroplasty and when assuming no detrimental impact of previous surgery on outcomes after arthroplasty. Clinical judgment should still be prioritized when formulating treatment plans for these patients. LEVEL OF EVIDENCE: Level II, economic decision analysis. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Sharma, Mona; Sinha, Renu; Trikha, Anjan; Ramachandran, Rashmi; Chandralekha, C
2016-08-01
Laryngeal mask airway (LMA) cuff pressure increases when the air is used for the cuff inflation during oxygen: nitrous oxide (O2:N2O) anaesthesia, which may lead to various problems. We compared the effects of different gases for ProSeal LMA™ (PLMA) cuff inflation in adult patients for various parameters. A total of 120 patients were randomly allocated to four groups, according to composition of gases used to inflate the PLMA cuff to achieve 40 cmH2 O cuff pressure, air (Group A), 50% O2 :air (Group OA), 50% O2:N2O (Group ON) and 100% O2 (Group O). Cuff pressure, cuff volume and ventilator parameters were monitored intraoperatively. Pharyngolaryngeal parameters were assessed at 1, 2 and 24 h postoperatively. Statistical analysis was performed using ANOVA, Fisher's exact test and step-wise logistic regression. Cuff pressure significantly increased at 10, 15 and 30 min in Group A, OA and O from initial pressure. Cuff pressure decreased at 5 min in Group ON (36.6 ± 3.5 cmH2 O) (P = 0.42). PLMA cuff volume increased in Group A, OA, O, but decreased in Group ON (6.16 ± 2.8 ml [P < 0.001], 4.7 ± 3.8 ml [P < 0.001], 1.4 ± 3.19 ml [P = 0.023] and - 1.7 ± 4.9 ml [P = 0.064], respectively), from basal levels. Ventilatory parameters were comparable in all four groups. There was no significant association between sore throat and cuff pressure, with odds ratio 1.002. Cuff inflation with 50% O2:N2O mixture provided more stable cuff pressure in comparison to air, O2 :air, 100% O2 during O2:N2O anaesthesia. Ventilatory parameters did not change with variation in PLMA cuff pressure. Post-operative sore throat had no correlation with cuff pressure.
Ghai, Babita; Sethi, Sameer; Ram, Jagat; Wig, Jyotsna
2013-02-01
Clinical end points are often used to guide inflation and adequacy of cuff seal after laryngeal mask airway placement. However, clinical end points for cuff inflation have been shown to have significantly higher intracuff pressure. The adjusted cuff pressure between 55 and 60 cm H(2)O causes significantly better seal of laryngeal mask airway. We prospectively assessed the cuff pressures generated by cuff inflation guided by clinical end points, and the actual volume of air required to achieve cuff pressures between 55 and 60 cm H(2)O for sizes 1-2.5 reusable classic laryngeal mask airway. Two hundred and three ASA I and II children undergoing elective cataract surgery requiring general anesthesia receiving laryngeal mask airway sizes 1-2.5 were recruited to this study. The laryngeal mask airway was placed using standard technique. After insertion of laryngeal mask airway, the cuff was slowly inflated until a slight outward shift of device was noted. Cuff pressures were measured using calibrated hand held Portex Cuff Inflator Pressure Gauge (Portex Limited, Hythe, Kent, UK). If the cuff pressure was >60 cm H(2)O, the cuff was deflated to achieve a cuff pressure of 55-60 cm H(2)O. The volume of air required to achieve this pressure was recorded. The volume of air required to achieve the pressure between 55 and 60 cm H(2)O in laryngeal mask airway size 1, 1.5, 2.0, and 2.5 were 2.750 ± 0.2565, 4.951 ± 0.5378, 6.927 ± 0.6328, and 10.208 ± 1.4535 ml, respectively. The difference between the initial and the final cuff volumes and pressures in all laryngeal mask airway sizes were statistically significant(P = 0.000). Lower cuff volumes are required to achieve a pressure of 60 cm H(2)O than those required if clinical end points are used as a sole guide for determining cuff inflation for patients receiving pediatric laryngeal mask airways. © 2012 Blackwell Publishing Ltd.
Model-based Bayesian signal extraction algorithm for peripheral nerves
NASA Astrophysics Data System (ADS)
Eggers, Thomas E.; Dweiri, Yazan M.; McCallum, Grant A.; Durand, Dominique M.
2017-10-01
Objective. Multi-channel cuff electrodes have recently been investigated for extracting fascicular-level motor commands from mixed neural recordings. Such signals could provide volitional, intuitive control over a robotic prosthesis for amputee patients. Recent work has demonstrated success in extracting these signals in acute and chronic preparations using spatial filtering techniques. These extracted signals, however, had low signal-to-noise ratios and thus limited their utility to binary classification. In this work a new algorithm is proposed which combines previous source localization approaches to create a model based method which operates in real time. Approach. To validate this algorithm, a saline benchtop setup was created to allow the precise placement of artificial sources within a cuff and interference sources outside the cuff. The artificial source was taken from five seconds of chronic neural activity to replicate realistic recordings. The proposed algorithm, hybrid Bayesian signal extraction (HBSE), is then compared to previous algorithms, beamforming and a Bayesian spatial filtering method, on this test data. An example chronic neural recording is also analyzed with all three algorithms. Main results. The proposed algorithm improved the signal to noise and signal to interference ratio of extracted test signals two to three fold, as well as increased the correlation coefficient between the original and recovered signals by 10-20%. These improvements translated to the chronic recording example and increased the calculated bit rate between the recovered signals and the recorded motor activity. Significance. HBSE significantly outperforms previous algorithms in extracting realistic neural signals, even in the presence of external noise sources. These results demonstrate the feasibility of extracting dynamic motor signals from a multi-fascicled intact nerve trunk, which in turn could extract motor command signals from an amputee for the end goal of controlling a prosthetic limb.
Lewis, P; Naqvi, S; Mandal, P; Potluri, P
2015-06-01
Sphygmomanometer cuff pressure during deflation is assumed to equal systolic arterial pressure at the point of resumption of flow. Previous studies demonstrated that pressure decreases with increasing depth of soft tissues whilst visco-elastic characteristics of the arm tissue cause spatial and temporal variation in pressure magnitude. These generally used non-anatomical axisymmetrical arm simulations without incorporating arterial pressure variation. We used data from a volunteer's Magnetic Resonance (MR) arm scan and investigated the effect of variations in cuff materials and construction on the simulated transmission of pressure from under the cuff to the arterial wall under sinusoidal flow conditions. Pressure was measured under 8 different cuffs using Oxford Pressure Monitor Sensors placed at 90 degrees around the mid upper arm of a healthy male. Each cuff was inflated 3 times to 155 mmHg and then deflated to zero with 90 seconds between inflations. Young's modulus, flexural rigidity and thickness of each cuff was measured.Using DICOM data from the MR scan of the arm, a 3D model was derived using ScanIP and imported into Abaqus for Finite Element Analysis (FEA). Published mechanical properties of arm tissues and geometric non-linearity were assumed. The measured sub-cuff pressures were applied to the simulated arm and pressure was calculated around the brachial arterial wall. which was loaded with a sinusoidal pressure of 125/85 mmHg. FEA estimates of pressure around the brachial artery cuffs varied by up to 27 mmHg SBP and 17 mmHg DBP with different cuffs. Pressures within the cuffs varied up to 27 mmHg. Pressure transmission from the cuff to the arterial surface achieved a 95% transmission ratio with one rubber-bladdered cuff but varied between 76 and 88% for the others. Non-uniform pressure distribution around the arterial wall was strongly related to cuff fabric elastic modulus. Identical size cuffs with a separate rubber bladder produced peri-arterial pressure 14 mmHg higher than with a fabric bladder.(Figure is included in full-text article.) : Wide variations of pressure within and under cuffs and at the artery wall interface, dependent on differing cuff materials and construction, may critically affect blood pressure measurement.
Takahashi, N; Sugaya, H; Matsuki, K; Miyauchi, H; Matsumoto, M; Tokai, M; Onishi, K; Hoshika, S; Ueda, Y
2017-06-01
The aim of this study was to assess hypertrophy of the extra-articular tendon of the long head of biceps (LHB) in patients with a rotator cuff tear. The study involved 638 shoulders in 334 patients (175 men, 159 women, mean age 62.6 years; 25 to 81) with unilateral symptomatic rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon in the bicipital groove was measured pre-operatively in both shoulders using ultrasound. There were 154 asymptomatic rotator cuff tears in the contralateral shoulder. Comparisons were made between those with a symptomatic tear, an asymptomatic tear and those with no rotator cuff tear. In the affected shoulders, the CSAs were compared in relation to the location and size of the rotator cuff tear. The mean CSA was 21.0 mm 2 (4 to 71) in those with a symptomatic rotator cuff tear, 19.9 mm 2 (4 to 75) in those with an asymptomatic rotator cuff tear and 14.1 mm 2 (5 to 43) in those with no rotator cuff tear. The mean CSA in patients with both symptomatic and asymptomatic rotator cuff tears was significantly larger than in those with no rotator cuff tear (p < 0.001). In the affected shoulders, there were significant differences between patients with more than a medium sized posterosuperior cuff tear and those with an antero-superior cuff tear. Regardless of the symptoms, there was significant hypertrophy of the extra-articular LHB tendon in patients with a rotator cuff tear. The values were significantly related to the size of the tear. Cite this article: Bone Joint J 2017;99-B:806-11. ©2017 The British Editorial Society of Bone & Joint Surgery.
On cuff imbalance and tripolar ENG amplifier configurations.
Triantis, Iasonas F; Demosthenous, Andreas; Donaldson, Nick
2005-02-01
Electroneurogram (ENG) recording techniques benefit from the use of tripolar cuffs because they assist in reducing interference from sources outside the cuff. However, in practice the performance of ENG amplifier configurations, such as the quasi-tripole and the true-tripole, has been widely reported to be degraded due to the departure of the tripolar cuff from ideal behavior. This paper establishes the presence of cuff imbalance and investigates its relationship to cuff asymmetry, cuff end-effects and interference source proximity. The paper also presents a comparison of the aforementioned amplifier configurations with a new alternative, termed the adaptive-tripole, developed to automatically compensate for cuff imbalance. The output signal-to-interference ratio of the three amplifier configurations were compared in vivo for two interference signals (stimulus artifact and M-wave) superimposed on compound action potentials. The experiments showed (for the first time) that the two interference signals result in different cuff imbalance values. Nevertheless, even with two distinct cuff imbalances present, the adaptive-tripole performed better than the other two systems in 61.9% of the trials.
Evidence of multipolar response of Bacteriorhodopsin by noncollinear second harmonic generation.
Bovino, F A; Larciprete, M C; Sibilia, C; Váró, G; Gergely, C
2012-06-18
Noncollinear second harmonic generation from a Bacteriorhodopsin (BR) oriented multilayer film was systematically investigated by varying the polarization state of both fundamental beams. Both experimental results and theoretical simulations, show that the resulting polarization mapping is an useful tool to put in evidence the optical chirality of the investigated film as well as the corresponding multipolar contributions to the nonlinear.
... smooth layer) lining these tendons. A rotator cuff tear occurs when one of the tendons is torn ... Poor posture over many years Aging Rotator cuff tears TEARS Rotator cuff tears may occur in two ...
Indications for reverse total shoulder arthroplasty in rotator cuff disease.
Drake, Gregory N; O'Connor, Daniel P; Edwards, T Bradley
2010-06-01
Reverse total shoulder arthroplasty (RTSA) was introduced to treat rotator cuff tear arthropathy but is now used to treat a variety of problems. Although its use has expanded substantially since the FDA's approval in 2004, the appropriateness in patients with rotator cuff disease is unclear. We review the use of RTSA in patients with rotator cuff disease to (1) describe classification of rotator cuff tear reparability and the concept of a balanced shoulder; (2) explore the theory behind RTSA design relative to rotator cuff arthropathy; (3) discuss the indications and contraindications for RTSA; and (4) review published outcomes of RTSA for rotator cuff arthropathy. We performed a selective review of the literature on the use of RTSA in the treatment of rotator cuff disease. Modern RTSA designs restore deltoid tension and a functional fulcrum to the rotator cuff deficient shoulder, which allows recovery of active shoulder elevation and effectively restores function in short- and medium-term followup studies. In short-term followup the RTSA relieves symptoms and restores function for patients with cuff tear arthropathy and irreparable rotator cuff tears with pseudoparalysis (preserved deltoid contraction but loss of active elevation). Severely impaired deltoid function, an isolated supraspinatus tear, and the presence of full active shoulder elevation with a massive rotator cuff tear and arthritis are contraindications to RTSA. For properly selected patients who have symptomatic and disabling rotator cuff deficiency, RTSA can result in life-changing improvements in pain, motion, function, and patient satisfaction. Level V therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Kretschmer, Alexander; Hüsch, Tanja; Thomsen, Frauke; Kronlachner, Dominik; Obaje, Alice; Anding, Ralf; Pottek, Tobias; Rose, Achim; Olianas, Roberto; Friedl, Alexander; Hübner, Wilhelm; Homberg, Roland; Pfitzenmaier, Jesco; Grein, Ulrich; Queissert, Fabian; Naumann, Carsten Maik; Schweiger, Josef; Wotzka, Carola; Nyarangi-Dix, Joanne N; Hofmann, Torben; Seiler, Roland; Haferkamp, Axel; Bauer, Ricarda M
2016-01-01
Background/Aims/Objectives: To analyze perioperative complication and short-term explantation rates after perineal or penoscrotal single-cuff and double-cuff artificial urinary sphincter (AUS) implantation in a large middle European multi-institutional patient cohort. 467 male patients with stress urinary incontinence underwent implantation of a perineal single-cuff (n = 152), penoscrotal single-cuff (n = 99), or perineal double-cuff (n = 216) AUS between 2010 and 2012. Postoperative complications and 6-month explantation rates were assessed. For statistical analysis, Fisher's exact test and Kruskal-Wallis rank sum test, and a multiple logistic regression model were used (p < 0.05). Compared to perineal single-cuff AUS, penoscrotal single-cuff implantation led to significantly increased short-term explantation rates (8.6% (perineal) vs. 19.2% (penoscrotal), p = 0.019). The postoperative infection rate was significantly higher after double-cuff compared to single-cuff implantation (6.0% (single-cuff) vs. 13.9% (double-cuff), p = 0.019). The short-term explantation rate after primary double-cuff placement was 6.5% (p = 0.543 vs. perineal single-cuff). In multivariate analysis, the penoscrotal approach (p = 0.004), intraoperative complications (p = 0.005), postoperative bleeding (p = 0.011), and perioperative infection (p < 0.001) were independent risk factors for short-term explantation. Providing data from a large contemporary multi-institutional patient cohort from high-volume and low-volume institutions, our results reflect the current standard of care in middle Europe. We indicate that the penoscrotal approach is an independent risk factor for increased short-term explantation rates. © 2016 S. Karger AG, Basel.
Integration of High-Charge-Injection-Capacity Electrodes onto Polymer Softening Neural Interfaces.
Arreaga-Salas, David E; Avendaño-Bolívar, Adrian; Simon, Dustin; Reit, Radu; Garcia-Sandoval, Aldo; Rennaker, Robert L; Voit, Walter
2015-12-09
Softening neural interfaces are implanted stiff to enable precise insertion, and they soften in physiological conditions to minimize modulus mismatch with tissue. In this work, a high-charge-injection-capacity iridium electrode fabrication process is detailed. For the first time, this process enables integration of iridium electrodes onto softening substrates using photolithography to define all features in the device. Importantly, no electroplated layers are utilized, leading to a highly scalable method for consistent device fabrication. The iridium electrode is metallically bonded to the gold conductor layer, which is covalently bonded to the softening substrate via sulfur-based click chemistry. The resulting shape-memory polymer neural interfaces can deliver more than 2 billion symmetric biphasic pulses (100 μs/phase), with a charge of 200 μC/cm(2) and geometric surface area (GSA) of 300 μm(2). A transfer-by-polymerization method is used in combination with standard semiconductor processing techniques to fabricate functional neural probes onto a thiol-ene-based, thin film substrate. Electrical stability is tested under simulated physiological conditions in an accelerated electrical aging paradigm with periodic measurement of electrochemical impedance spectra (EIS) and charge storage capacity (CSC) at various intervals. Electrochemical characterization and both optical and scanning electron microscopy suggest significant breakdown of the 600 nm-thick parylene-C insulation, although no delamination of the conductors or of the final electrode interface was observed. Minor cracking at the edges of the thin film iridium electrodes was occasionally observed. The resulting devices will provide electrical recording and stimulation of the nervous system to better understand neural wiring and timing, to target treatments for debilitating diseases, and to give neuroscientists spatially selective and specific tools to interact with the body. This approach has uses for cochlear implants, nerve cuff electrodes, penetrating cortical probes, spinal stimulators, blanket electrodes for the gut, stomach, and visceral organs and a host of other custom nerve-interfacing devices.
Carter, Eleanor L; Duguid, Alasdair; Ercole, Ari; Matta, Basil; Burnstein, Rowan M; Veenith, Tonny
2014-03-01
Ventilation-associated pneumonia (VAP) is the commonest nosocomial infection in intensive care. Implementation of a VAP prevention care bundle is a proven method to reduce its incidence. The UK care bundle recommends maintenance of the tracheal tube cuff pressure at 20 to 30 cmH₂O with 4-hourly pressure checks and use of tracheal tubes with subglottic aspiration ports in patients admitted for more than 72 h. To evaluate the effects of tracheal tube type and cuff pressure monitoring technique on leakage of subglottic secretions past the tracheal tube cuff. Bench-top study. Laboratory. A model adult trachea with simulated subglottic secretions was intubated with a tracheal tube with the cuff inflated to 25 cmH₂O. Experiments were conducted using a Portex Profile Soft Seal tracheal tube with three cuff pressure monitoring strategies and using a Portex SACETT tracheal tube with intermittent cuff pressure checks. Rate of simulated secretion leakage past the tracheal tube cuff. Mean ± SD leakage of fluid past the Profile Soft Seal tracheal tube cuff was 2.25 ± 1.49 ml min⁻¹ with no monitoring of cuff pressure, 2.98 ± 1.63 ml min⁻¹ with intermittent cuff pressure monitoring and 3.83 ± 2.17 ml min⁻¹ with continuous cuff pressure monitoring (P <0.001). Using a SACETT tracheal tube with a subglottic aspiration port and aspirating the simulated secretions prior to intermittent cuff pressure checks reduced the leakage rate to 0.50 ± 0.48 ml min⁻¹ (P <0.001). Subglottic secretions leaked past the tracheal tube cuff with all tube types and cuff pressure monitoring strategies in this model. Significantly higher rates were observed with continuous cuff pressure monitoring and significantly lower rates were observed when using a tracheal tube with a subglottic aspiration port. Further evaluation of medical device performance is needed in order to design more effective VAP prevention strategies.
From dipolar to multipolar interactions between ultracold Feshbach molecules
NASA Astrophysics Data System (ADS)
Quéméner, Goulven; Lepers, Maxence; Luc-Koenig, Eliane; Dulieu, Olivier
2016-05-01
Using the multipolar expansion of electrostatic and magnetostatic potential energies, we characterize the long-range interactions between two weakly-bound diatomic molecules, taking as an example the paramagnetic Er2 Feshbach molecules which were produced recently. The interaction between atomic magnetic dipoles gives rise to the usual R-3 leading term of the multipolar expansion, where R is the intermolecular distance. We show that additional terms scaling as R-5, R-7 and so on also appear, which are strongly anisotropic with respect to the orientation of the molecules. These terms can be seen as effective molecular multipole moments reflecting the spatial extension of the molecules which is non-negligible compared to R. We acknowledge the financial support of the COPOMOL project (ANR-13-IS04-0004) from Agence Nationale de la Recherche.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-25
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 13880-000] Cuffs Run Pumped..., Motions To Intervene, and Competing Applications On November 18, 2010, Cuffs Run Pumped Storage, LLC filed... to study the feasibility of the Cuffs Run Pumped Storage Project, located on Cuffs Run and the...
[Methodical aspects of pneumatic segment plethysmography. III. Measuring tourniquet problems].
Bethge, K P; de Caleya, D
1976-08-01
The question, to which extent utilization of different plethysmographic cuffs influenced the assessment of volume changes, was examined in 40 healthy individuals as well as by means of an experimental model. It could be shown that plethysmographic results varied significantly according to the design of the cuffs: 1.a) Utilization of short (19.5 cm) cuffs that did not cover the entire thigh circumference resulted in significantly lower arterial inflow and pressure-dependent venous capacity measurements as compared to long cuffs (48.8 cm). b) This result was confirmed by use of a newly developed "calibration-cylinder" demonstrating that use of the short cuff showed only 62.2% of the true volume change, use of the long cuff, however, 89.6%. Deficiency of thigh contact is discussed as possible etiologic factor for this difference. 2. The cover material of the cuff also influenced the results significantly since results could be improved from 62.2% to 86.9% (short cuff) and from 89.6% to 95.1% (long cuff) by use of double layer non-compliant cloth. The reason for this finding is thought to be the compliance of conventional cloth. 3. Comparison of two cuffs with identical shape and dimensions resulted in significantly lower volume changes using hard stiff rubber as compared to soft compliant rubber. These findings suggest some recommendations for optimal design of plethysmographic cuffs. Cuffs should not underestimate volume changes obtained with the "calibration-cylinder" by more than 10%.
Acquired tracheoesophageal fistula due to high intracuff pressure.
Hameed, Akmal A; Mohamed, Hasan; Al-Mansoori, Motasem
2008-01-01
High-compliance endotracheal tube cuffs are used to prevent gas leak and also pulmonary aspiration in mechanically ventilated patients. However, the use of the usual cuff inflation volumes may cause tracheal damage and lead to tracheoesophageal fistula.Tracheostomy tube cuffs seal against the tracheal wall and prevent leakage of air around the tube, assuring that the tidal volume is delivered to the lungs. In the past, high-pressure cuffs were used, but these contributed to tracheal injury and have been replaced by high-volume, low-pressure cuffs. For long-term applications, some newer tubes have low-profile (tight to shaft) cuffs that facilitate the tracheostomy tube changes by eliminating the lip that forms when standard cuffs are deflated.
Handcrafted cuff manometers do not accurately measure endotracheal tube cuff pressure
Annoni, Raquel; de Almeida, Antonio Evanir
2015-01-01
Objective To test the agreement between two handcrafted devices and a cuff-specific manometer. Methods The agreement between two handcrafted devices adapted to measure tracheal tube cuff pressure and a cuff-specific manometer was tested on 79 subjects. The cuff pressure was measured with a commercial manometer and with two handcrafted devices (HD) assembled with aneroid sphygmomanometers (HD1 and HD2). The data were compared using Wilcoxon and Spearman tests, the intraclass correlation coefficient (ICC) and limit-of-agreement analysis. Results Cuff pressures assessed with handcrafted devices were significantly different from commercial device measurements (pressures were higher when measured with HD1 and lower with HD2). The ICCs between the commercial device and HD1 and HD2 were excellent (ICC = 0.8 p < 0.001) and good (ICC = 0.66, p < 0.001), respectively. However, the Bland- Altman plots showed wide limits of agreement between HD1 and HD2 and the commercial device. Conclusion The handcrafted manometers do not provide accurate cuff pressure measurements when compared to a cuff-specific device and should not be used to replace the commercial cuff manometers in mechanically ventilated patients. PMID:26376160
Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study.
Dave, M H; Frotzler, A; Spielmann, N; Madjdpour, C; Weiss, M
2010-10-01
This study compared the fluid leakage in the new 'tapered' shaped against the classic 'cylindrical' shaped tracheal tube cuffs when placed in different sized tracheas. The 7.5 mm internal diameter (ID) tracheal tube cuffs-Tapered Seal Guard (TSG), Standard Seal Guard (SSG), Hi-Lo, Microcuff, Ruesch, and Portex Profile-were compared in an in vitro apparatus. Vertical artificial tracheas with 16, 20, and 22 mm ID were intubated, 5 ml clear water was applied above the unlubricated tube cuffs, and fluid leakage was measured up to 60 min. Data of tapered vs non-tapered tube cuffs (16 observations) were compared for each tracheal diameter using the Mann-Whitney test. Median (range) fluid leakage (ml) at 60 min was 2.14 (0.05-4.88), 1.14 (0.00-4.84), and 0.13 (0.00-1.32), respectively, for 16, 20, and 22 mm tracheas in the TSG tube studies when compared with 4.58 (0.44-4.88), 2.21 (0.00-4.81), and 0.00 (0.00-4.81) in the SSG tube and 4.54 (1.54-4.82), 0.90 (0.00-4.49), and 4.85 (4.40-4.99) in the Microcuff tube studies. Leakage in all polyvinylchloride (PVC) tube cuffs was almost complete (5 ml) within 5 min (P<0.001). The tapered PU tube cuff was as effective as the cylindrical PU cuffs in smaller tracheal diameters and was more efficient than the cylindrical Microcuff PU tube cuff in larger tracheal diameter in preventing subglottic fluid leakage across the tube cuff tested in this in vitro study. PVC tube cuffs leaked much more and faster than PU cuffs.
Cancienne, Jourdan M; Brockmeier, Stephen F; Rodeo, Scott A; Young, Chris; Werner, Brian C
2017-07-01
To evaluate the association of postoperative fluoroquinolone use following arthroscopic primary rotator cuff repair with failure requiring revision rotator cuff repair. An insurance database was queried for patients undergoing rotator cuff repair from 2007 to 2015. These patients were divided into three groups: (1) patients prescribed fluoroquinolones within 6 months postoperatively (divided into 0-2, 2-4, and 4-6 months), (2) a matched negative control cohort of patients not prescribed fluoroquinolones, and (3) a matched positive control cohort of patients prescribed fluoroquinolones between 6 and 18 months following rotator cuff repair. Rates of failure requiring revision rotator cuff repair were compared within 2 years. A total of 1292 patients were prescribed fluoroquinolones within 6 months after rotator cuff repair, including 442 within 2 months, 433 within 2 to 4 months, and 417 within 4 to 6 months, and were compared to 5225 matched negative controls and 1597 matched positive controls. The rate of revision rotator cuff repair was significantly higher in patients prescribed fluoroquinolones within 2 months (6.1 %) compared to matched negative (2.2 %, P = 0.0009) and positive controls (2.4 %, P = 0.0026). There were no significant differences in the rate of revision rotator cuff repair when fluoroquinolones were prescribed >2 months after rotator cuff repair. Early use of fluoroquinolones following rotator cuff repair was independently associated with significantly increased rates of failure requiring revision rotator cuff repair. This is the first clinical study examining the association of postoperative fluoroquinolone use with failure following arthroscopic rotator cuff repair. III.
Mission from Anti-Terrorism to Peace in Sri Lanka
2009-03-24
citizens working together. Endnotes 1 Asoka Bandarage, “The Sri Lankan Conflict a Multi-Polar Approach,” Harvard International Review, 15 June 2008...8 Asoka Bandarage, “The Sri Lankan Conflict a Multi-Polar Approach”, Harvard International Review, 15 June 2008, available from...Eastern University Press, 2003), 222. 24 H. Kaunaratna. BA (Ceylon) University of Peradeniya, Sri Lanka, interviewed by author, 25 November 2008. 25 Asoka
Statistical Analysis to Develop a Three-Dimensional Surface Model of a Midsize-Male Foot
2013-10-31
alignment of the landmarks was conducted to remove differences in posture, particularly rotation about the...edge of long underwear cuff at midline of ankle 59 9 CuffInfEdge_MalleolusLateral Interior edge of long underwear cuff superior to lateral malleolus...60 0 CuffInfEdge_AnkleMidline_Posterior Posterior-inferior edge of long underwear cuff at midline of ankle 61 1 CuffInfEdge_MalleolusMedial Interior
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Lei; Yu, Cong, E-mail: muduri@shao.ac.cn, E-mail: cyu@ynao.ac.cn
2014-04-01
We propose a catastrophic eruption model for the enormous energy release of magnetars during giant flares, in which a toroidal and helically twisted flux rope is embedded within a force-free magnetosphere. The flux rope stays in stable equilibrium states initially and evolves quasi-statically. Upon the loss of equilibrium, the flux rope cannot sustain the stable equilibrium states and erupts catastrophically. During the process, the magnetic energy stored in the magnetosphere is rapidly released as the result of destabilization of global magnetic topology. The magnetospheric energy that could be accumulated is of vital importance for the outbursts of magnetars. We carefullymore » establish the fully open fields and partially open fields for various boundary conditions at the magnetar surface and study the relevant energy thresholds. By investigating the magnetic energy accumulated at the critical catastrophic point, we find that it is possible to drive fully open eruptions for dipole-dominated background fields. Nevertheless, it is hard to generate fully open magnetic eruptions for multipolar background fields. Given the observational importance of the multipolar magnetic fields in the vicinity of the magnetar surface, it would be worthwhile to explore the possibility of the alternative eruption approach in multipolar background fields. Fortunately, we find that flux ropes may give rise to partially open eruptions in the multipolar fields, which involve only partial opening of background fields. The energy release fractions are greater for cases with central-arcaded multipoles than those with central-caved multipoles that emerged in background fields. Eruptions would fail only when the centrally caved multipoles become extremely strong.« less
Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs.
Kumar, R D C; Hirsch, N P
2011-11-01
Tracheal tube cuffs are commonly inflated to pressures exceeding the recommended upper limit of 30 cmH(2)O. We evaluated whether a stethoscope-guided method of cuff inflation results in pressures within the recommended range. Patients were randomly assigned to receive one of two methods of cuff inflation. In the standard 'just seal' group, air was introduced into the tracheal cuff until the audible leak at the mouth disappeared. In the stethoscope-guided group, air was introduced into the cuff until a change from harsh to soft breath sounds occurred, whilst listening with a stethoscope bell placed over the thyroid cartilage. Twenty-five patients were recruited to each group. The median (IQR [range]) cuff pressure in the 'just seal' group was 34 (28-40 [18-49]) cmH(2)O, and in the stethoscope-guided group was 20 (20-26 [16-28]) cmH(2)O, p < 0.0001. The stethoscope-guided method of tracheal tube cuff inflation is a novel, simple technique that reliably results in acceptable tracheal cuff pressures. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.
New suturing technique for robotic-assisted vaginal cuff closure during single-site hysterectomy.
Shin, So-Jin; Chung, Hyewon; Kwon, Sang-Hoon; Cha, Soon-Do; Cho, Chi-Heum
2017-06-01
To describe a simple and efficient technique for suturing the vaginal cuff in robotic-assisted single-site hysterectomy using barbed suture and a straight needle. Consecutive patients undergoing robotic-assisted single-site hysterectomy from February 2014 to August 2015 at Dong San Hospital, Keimyung University were included. Surgeons used two barbed sutures in a running fashion to close the vaginal cuff. A barbed suture was exclusively used with a straightened needle in upward direction from posterior vaginal cuff to anterior vaginal cuff which played a pivotal role for closure. A total of 100 patients underwent robotic-assisted single-site hysterectomy. The total operation time was 132.5 min and vaginal cuff closure time was 12.0 min. There were no postoperative complications; vaginal cuff dehiscence, vaginal cuff infection, and vaginal bleeding that require surgical intervention or admission. The use of barbed suture with straightened needle to close the vaginal cuff in robotic-assisted single-site hysterectomy is easy to perform and demonstrates safety and efficacy. This technique offers secure, fast, and effective incision closure.
Rotator cuff tendinopathy: a model for the continuum of pathology and related management.
Lewis, Jeremy S
2010-10-01
Pathology of the soft tissues of the shoulder including the musculotendinous rotator cuff and subacromial bursa are extremely common and are a principal cause of pain and suffering. Competing theories have been proposed to explain the pathoaetiology of rotator cuff pathology at specific stages and presentations of the condition. This review proposes a model to describe the continuum of the rotator cuff pathology from asymptomatic tendon through full thickness rotator cuff tears. The pathoaetiology of rotator cuff failure is multifactorial and results from a combination of intrinsic, extrinsic and environmental factors. Recently a new and generic model detailing the continuum of tendon pathology has been proposed. This model is relevant for the rotator cuff and provides a framework to stage the continuity of rotator cuff pathology. Furthermore, it provides a structure to identify the substantial deficiencies in our knowledge base and areas where research would improve our understanding of the pathological and repair process, together with assessment and management. The strength of this model adapted for the rotator cuff tendons and subacromial bursa will be tested in its ability to incorporate and adapt to emerging research.
Electromyographical Comparison of Four Common Shoulder Exercises in Unstable and Stable Shoulders
Sciascia, Aaron; Kuschinsky, Nina; Nitz, Arthur J.; Mair, Scott D.; Uhl, Tim L.
2012-01-01
This study examines if electromyographic (EMG) amplitude differences exist between patients with shoulder instability and healthy controls performing scaption, prone horizontal abduction, prone external rotation, and push-up plus shoulder rehabilitation exercises. Thirty nine subjects were categorized by a single orthopedic surgeon as having multidirectional instability (n = 10), anterior instability (n = 9), generalized laxity (n = 10), or a healthy shoulder (n = 10). Indwelling and surface electrodes were utilized to measure EMG activity (reported as a % of maximum voluntary isometric contraction (MVIC)) in various shoulder muscles during 4 common shoulder exercises. The exercises studied effectively activated the primary musculature targeted in each exercise equally among all groups. The serratus anterior generated high activity (50–80% MVIC) during a push-up plus, while the infraspinatus and teres major generated moderate-to-high activity (30–80% MVIC) during both the prone horizontal and prone external rotation exercises. Scaption exercise generated moderate activity (20–50% MVIC) in both rotator cuff and scapular musculature. Clinicians should feel confident in prescribing these shoulder-strengthening exercises in patients with shoulder instability as the activation levels are comparable to previous findings regarding EMG amplitudes and should improve the dynamic stabilization capability of both rotator cuff and scapular muscles using exercises designed to address glenohumeral joint instability. PMID:22919499
Ultrasound determination of rotator cuff tear repairability
Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa
2015-01-01
Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p < 0.0001) and a specificity of 67% (p < 0.0001). The strongest predictors of rotator cuff repairability were tear size (p < 0.001) and age (p = 0.004). Sonographic assessments of tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996
Rothrauff, Benjamin B; Pauyo, Thierry; Debski, Richard E; Rodosky, Mark W; Tuan, Rocky S; Musahl, Volker
2017-08-01
The torn rotator cuff remains a persistent orthopedic challenge, with poor outcomes disproportionately associated with chronic, massive tears. Degenerative changes in the tissues that comprise the rotator cuff organ, including muscle, tendon, and bone, contribute to the poor healing capacity of chronic tears, resulting in poor function and an increased risk for repair failure. Tissue engineering strategies to augment rotator cuff repair have been developed in an effort to improve rotator cuff healing and have focused on three principal aims: (1) immediate mechanical augmentation of the surgical repair, (2) restoration of muscle quality and contractility, and (3) regeneration of native enthesis structure. Work in these areas will be reviewed in sequence, highlighting the relevant pathophysiology, developmental biology, and biomechanics, which must be considered when designing therapeutic applications. While the independent use of these strategies has shown promise, synergistic benefits may emerge from their combined application given the interdependence of the tissues that constitute the rotator cuff organ. Furthermore, controlled mobilization of augmented rotator cuff repairs during postoperative rehabilitation may provide mechanotransductive cues capable of guiding tissue regeneration and restoration of rotator cuff function. Present challenges and future possibilities will be identified, which if realized, may provide solutions to the vexing condition of chronic massive rotator cuff tears.
Blood pressure control with selective vagal nerve stimulation and minimal side effects
NASA Astrophysics Data System (ADS)
Plachta, Dennis T. T.; Gierthmuehlen, Mortimer; Cota, Oscar; Espinosa, Nayeli; Boeser, Fabian; Herrera, Taliana C.; Stieglitz, Thomas; Zentner, Joseph
2014-06-01
Objective. Hypertension is the largest threat to patient health and a burden to health care systems. Despite various options, 30% of patients do not respond sufficiently to medical treatment. Mechanoreceptors in the aortic arch relay blood pressure (BP) levels through vagal nerve (VN) fibers to the brainstem and trigger the baroreflex, lowering the BP. Selective electrical stimulation of these nerve fibers reduced BP in rats. However, there is no technique described to localize and stimulate these fibers inside the VN without inadvertent stimulation of non-baroreceptive fibers causing side effects like bradycardia and bradypnea. Approach. We present a novel method for selective VN stimulation to reduce BP without the aforementioned side effects. Baroreceptor compound activity of rat VN (n = 5) was localized using a multichannel cuff electrode, true tripolar recording and a coherent averaging algorithm triggered by BP or electrocardiogram. Main results. Tripolar stimulation over electrodes near the barofibers reduced the BP without triggering significant bradycardia and bradypnea. The BP drop was adjusted to 60% of the initial value by varying the stimulation pulse width and duration, and lasted up to five times longer than the stimulation. Significance. The presented method is robust to impedance changes, independent of the electrode's relative position, does not compromise the nerve and can run on implantable, ultra-low power signal processors.
Multimodal nonlinear nanophotonics (Conference Presentation)
NASA Astrophysics Data System (ADS)
Kivshar, Yuri S.
2017-05-01
Nonlinear nanophotonics is a rapidly developing field of research with many potential applications for the design of nonlinear nanoantennas, light sources, nanolasers, and ultrafast miniature metadevices. A tight confinement of the local electromagnetic fields in resonant photonic nanostructures can boost nonlinear optical effects, thus offering versatile opportunities for the subwavelength control of light. To achieve the desired functionalities, it is essential to gain flexible control over the near- and far-field properties of nanostructures. To engineer nonlinear scattering from resonant nanoscale elements, both modal and multipolar control of the nonlinear response are widely exploited for enhancing the near-field interaction and optimizing the radiation directionality. Motivated by the recent progress of all-dielectric nanophotonics, where the electric and magnetic multipolar contributions may become comparable, here we review the advances in the recently emerged field of multipolar nonlinear nanophotonics, starting from earlier relevant studies of metallic and metal-dielectric structures supporting localized plasmonic resonances to then discussing the latest results for all-dielectric nanostructures driven by Mie-type multipolar resonances and optically induced magnetic response. These recent developments suggest intriguing opportunities for a design of nonlinear subwavelength light sources with reconfigurable radiation characteristics and engineering large effective optical nonlinearities at the nanoscale, which could have important implications for novel nonlinear photonic devices operating beyond the diffraction limit.
Force-balance model of suppression of multipolar division in cancer cells with extra centrosomes
NASA Astrophysics Data System (ADS)
Zhu, Jie
2013-03-01
Cancer cells often possess extra centrosomes which have the potential to cause cell death due to catastrophic multipolar division. Many cancer cells, however, are able to escape multipolar mitosis by clustering the extra centrosomes to form bipolar spindles. The mechanism of centrosome clustering is therefore of great interest to the development of anti-cancer drugs because the de-clustering of extra centrosomes provides an appealing way to eliminate cancer cells while keeping healthy cells intact. We present a physical model assuming 1) dynamic centrosomal microtubules interact with chromosomes by both pushing on chromosome arms and pulling along kinetochores; 2) these microtubules interact with force generators associated with actin/adhesion structures at the cell boundary; and 3) motors act on anti-parallel microtubules from different centrosomes. We find via computer simulations that chromosomes tend to aggregate near the cell center while centrosomes can be either clustered to form bipolar spindles or scattered to form multipolar spindles, depending on the strengths of relative forces, cell shape and adhesion geometry. The model predictions agree with data from cells plated on adhesive micropatterns and from biochemically or genetically perturbed cells. Furthermore, our model is able to explain various microtubule distributions in interphase cells on patterned substrates. This work was supported by NSF
Xie, Min-Jue; Yagi, Hideshi; Kuroda, Kazuki; Wang, Chen-Chi; Komada, Munekazu; Zhao, Hong; Sakakibara, Akira; Miyata, Takaki; Nagata, Koh-Ichi; Oka, Yuichiro; Iguchi, Tokuichi; Sato, Makoto
2013-06-01
Glia-guided migration (glia-guided locomotion) during radial migration is a characteristic yet unique mode of migration. In this process, the directionality of migration is predetermined by glial processes and not by growth cones. Prior to the initiation of glia-guided migration, migrating neurons transform from multipolar to bipolar, but the molecular mechanisms underlying this multipolar-bipolar transition and the commencement of glia-guided migration are not fully understood. Here, we demonstrate that the multipolar-bipolar transition is not solely a cell autonomous event; instead, the interaction of growth cones with glial processes plays an essential role. Time-lapse imaging with lattice assays reveals the importance of vigorously active growth cones in searching for appropriate glial scaffolds, completing the transition, and initiating glia-guided migration. These growth cone activities are regulated by Abl kinase and Cdk5 via WAVE2-Abi2 through the phosphorylation of tyrosine 150 and serine 137 of WAVE2. Neurons that do not display such growth cone activities are mispositioned in a more superficial location in the neocortex, suggesting the significance of growth cones for the final location of the neurons. This process occurs in spite of the "inside-out" principle in which later-born neurons are situated more superficially.
Schumann, R; Alyamani, O; Viswanath, A; Bonney, I
2016-01-01
The purpose of this study was to determine the correlation between body mass index (BMI) and upper and lower arm as well as lower leg circumferences and the frequency of correct blood pressure (BP) cuff fit. We explored recommendations for the most likely BP cuff size and location for the three BMI categories. Following IRB approval we retrospectively analyzed a research database of bariatric surgical patients with a BMI of ≥40 kg/m(2). Data included patients' characteristics, upper and lower arm as well as lower leg circumferences. Patients were divided into three groups based on BMI (kg/m(2), Group I: <45, Group II: 45-55, and Group III: >55). Appropriate cuff fit using a standard or large adult BP cuff (CRITIKON(®), GE Healthcare, Waukesha, Wisconsin, USA) on the upper and lower arm, and lower leg was determined. We analyzed the percent proportion of proper cuff fit for cuff sizes and locations between groups using appropriate nonparametric testing. Limb circumference correlated significantly with BMI (P = 0.01), and the upper arm correlated most closely (r = 0.76). A standard adult BP cuff on the lower arm fit properly in >90% and >80% and in Groups I and II, respectively. A large cuff on the lower arm was appropriate in 87% of Group III. In two participants, a large cuff fit properly on the lower leg. Limb circumference significantly correlated with BMI. Recommendations for proper cuff fit in different BMI categories can be made.
Neovascularization prevalence in the supraspinatus of patients with rotator cuff tendinopathy.
Kardouni, Joseph R; Seitz, Amee L; Walsworth, Matthew K; Michener, Lori A
2013-11-01
A high prevalence of neovascularity in lower extremity tendinopathies has been reported. Neovascularity in those with rotator cuff tendinopathy exclusively has not been examined. The objective was to determine the prevalence of neovascularization in patients with rotator cuff tendinopathy compared with asymptomatic controls. Single-blind cross-sectional study. Research laboratory. Participants (n = 40; age = 44.9 years, 23-62 years; 20 females) with rotator cuff tendinopathy (n = 20) but without full-thickness rotator cuff tears, and asymptomatic controls that were age, gender, and hand dominance matched (n = 20) to the patients. The participants laying in supine had their shoulder positioned in internal rotation and extension. Ultrasound images were collected of the supraspinatus tendon and subacromial bursae in the transverse and longitudinal planes using a linear transducer in color Doppler mode. Images were assessed for neovascularization by 2 trained raters who were blinded to group (rotator cuff tendinopathy or asymptomatic group). No statistically significant difference in neovascularization was identified between participants with and without rotator cuff tendinopathy (χ = 0.13, df = 1, P = 0.72). Neovascularization was identified in 6 of 20 patients with rotator cuff tendinopathy (30%) and 5 of 20 asymptomatic control participants (25%). The authors found no differences in neovascularization rate in patients with rotator cuff tendinopathy (30%) and asymptomatic controls (25%). The study indicates that neovascularization is not related to presence of symptomatic tendinopathy in those with rotator cuff tendinopathy. Neovascularization may not be a relevant sonographic finding to aid the clinical assessment of those with rotator cuff tendinopathy.
Rotator Cuff Deficient Arthritis of the Glenohumeral Joint
Macaulay, Alec A.; Greiwe, R. Michael
2010-01-01
Rotator cuff deficient arthritis of the glenohumeral joint, especially cuff tear arthropathy, has proved a challenging clinical entity for orthopaedic surgeons ever since Charles Neer originally detailed the problem in 1983. Understanding has improved regarding the pathophysiology and pathomechanics underlying cuff tear arthropathy. Surgical reconstruction options can lead to excellent outcomes for patients afflicted with these painful and functionally limited shoulders. Humeral hemiarthroplasty and reverse total shoulder arthroplasty have jumped to the forefront in the treatment of cuff tear arthropathy. As studies continue to look at the results of these procedures in cuff tear arthropathy, existing indications and treatment algorithms will be further refined. In this article the history and pathophysiology of cuff tear arthropathy are reviewed. Additionally, the clinical findings and results of surgical reconstruction are discussed. PMID:21119934
Altitude-Related Change in Endotracheal Tube Cuff Pressures in Helicopter EMS
Weisberg, Stacy N.; McCall, Jonathan C.; Tennyson, Joseph
2017-01-01
Introduction Over-inflation of endotracheal tube (ETT) cuffs has the potential to lead to scarring and stenosis of the trachea.1, 2,3, 4 The air inside an ETT cuff is subject to expansion as atmospheric pressure decreases, as happens with an increase in altitude. Emergency medical services helicopters are not pressurized, thereby providing a good environment for studying the effects of altitude changes ETT cuff pressures. This study aims to explore the relationship between altitude and ETT cuff pressures in a helicopter air-medical transport program. Methods ETT cuffs were initially inflated in a nonstandardized manner and then adjusted to a pressure of 25 cmH2O. The pressure was again measured when the helicopter reached maximum altitude. A final pressure was recorded when the helicopter landed at the receiving facility. Results We enrolled 60 subjects in the study. The mean for initial tube cuff pressures was 70 cmH2O. Maximum altitude for the program ranged from 1,000–3,000 feet above sea level, with a change in altitude from 800–2,480 feet. Mean cuff pressure at altitude was 36.52 ± 8.56 cmH2O. Despite the significant change in cuff pressure at maximum altitude, there was no relationship found between the maximum altitude and the cuff pressures measured. Conclusion Our study failed to demonstrate the expected linear relationship between ETT cuff pressures and the maximum altitude achieved during typical air-medical transportation in our system. At altitudes less than 3,000 feet above sea level, the effect of altitude change on ETT pressure is minimal and does not require a change in practice to saline-filled cuffs. PMID:28611883
Predicting Rotator Cuff Tears Using Data Mining and Bayesian Likelihood Ratios
Lu, Hsueh-Yi; Huang, Chen-Yuan; Su, Chwen-Tzeng; Lin, Chen-Chiang
2014-01-01
Objectives Rotator cuff tear is a common cause of shoulder diseases. Correct diagnosis of rotator cuff tears can save patients from further invasive, costly and painful tests. This study used predictive data mining and Bayesian theory to improve the accuracy of diagnosing rotator cuff tears by clinical examination alone. Methods In this retrospective study, 169 patients who had a preliminary diagnosis of rotator cuff tear on the basis of clinical evaluation followed by confirmatory MRI between 2007 and 2011 were identified. MRI was used as a reference standard to classify rotator cuff tears. The predictor variable was the clinical assessment results, which consisted of 16 attributes. This study employed 2 data mining methods (ANN and the decision tree) and a statistical method (logistic regression) to classify the rotator cuff diagnosis into “tear” and “no tear” groups. Likelihood ratio and Bayesian theory were applied to estimate the probability of rotator cuff tears based on the results of the prediction models. Results Our proposed data mining procedures outperformed the classic statistical method. The correction rate, sensitivity, specificity and area under the ROC curve of predicting a rotator cuff tear were statistical better in the ANN and decision tree models compared to logistic regression. Based on likelihood ratios derived from our prediction models, Fagan's nomogram could be constructed to assess the probability of a patient who has a rotator cuff tear using a pretest probability and a prediction result (tear or no tear). Conclusions Our predictive data mining models, combined with likelihood ratios and Bayesian theory, appear to be good tools to classify rotator cuff tears as well as determine the probability of the presence of the disease to enhance diagnostic decision making for rotator cuff tears. PMID:24733553
Altitude-Related Change in Endotracheal Tube Cuff Pressures in Helicopter EMS.
Weisberg, Stacy N; McCall, Jonathan C; Tennyson, Joseph
2017-06-01
Over-inflation of endotracheal tube (ETT) cuffs has the potential to lead to scarring and stenosis of the trachea.1, 2,3, 4 The air inside an ETT cuff is subject to expansion as atmospheric pressure decreases, as happens with an increase in altitude. Emergency medical services helicopters are not pressurized, thereby providing a good environment for studying the effects of altitude changes ETT cuff pressures. This study aims to explore the relationship between altitude and ETT cuff pressures in a helicopter air-medical transport program. ETT cuffs were initially inflated in a nonstandardized manner and then adjusted to a pressure of 25 cmH 2 O. The pressure was again measured when the helicopter reached maximum altitude. A final pressure was recorded when the helicopter landed at the receiving facility. We enrolled 60 subjects in the study. The mean for initial tube cuff pressures was 70 cmH 2 O. Maximum altitude for the program ranged from 1,000-3,000 feet above sea level, with a change in altitude from 800-2,480 feet. Mean cuff pressure at altitude was 36.52 ± 8.56 cmH 2 O. Despite the significant change in cuff pressure at maximum altitude, there was no relationship found between the maximum altitude and the cuff pressures measured. Our study failed to demonstrate the expected linear relationship between ETT cuff pressures and the maximum altitude achieved during typical air-medical transportation in our system. At altitudes less than 3,000 feet above sea level, the effect of altitude change on ETT pressure is minimal and does not require a change in practice to saline-filled cuffs.
Comparison between Two Endotracheal Tube Cuff Inflation Methods; Just-Seal Vs. Stethoscope-Guided.
Borhazowal, Rishiraj; Harde, Minal; Bhadade, Rakesh; Dave, Sona; Aswar, Swapnil Ganeshrao
2017-06-01
The Endotracheal Tube (ETT) cuff performs a critical function of sealing the airway during positive pressure ventilation. There is a narrow range of cuff pressure required to maintain a functionally safe seal without exceeding capillary blood pressure. We aimed to compare Just-Seal (JS) and Stethoscope-Guided (SG) method of ETT cuff inflation with respect to the volume of air required to inflate the cuff, the manometric cuff pressure achieved and also to assess for the occurrence of postoperative sore throat after extubation in both the groups. It was a prospective observational study done in a Tertiary Teaching Public Hospital over a period of 1½ years on 100 patients with 50 each in two groups; JS or SG method of cuff inflation. SPSS Version 17 was used for data analysis. Statistically significant difference (p-value of less than 0.05) was noted between the two methods based on the volume of air injected into the cuff {the mean volume injected in JS was 6.79 ml and in the SG was 4.95 ml with p=5.71E-16 (< 0.05)} and cuff pressure achieved {mean cuff pressure achieved was 38.80 cm H 2 O in the JS and 29.64 cm H 2 O in SG with p=2.29E-14 (< 0.05)}. The incidence of post extubation sore throat was 54% (27 in 50) in the JS group and only 12% (6 in 50) in the SG; p= 0.00000797. ETT cuff inflation guided by a stethoscope is an effective technique for ensuring appropriate cuff pressures thus accomplishing the objective of providing safe and superior quality care of the patient both during and after anaesthesia and reducing the likelihood of even minimal risk complications that may still have legal implications.
Ventilatory responses to dynamic exercise elicited by intramuscular sensors
NASA Technical Reports Server (NTRS)
Smith, S. A.; Gallagher, K. M.; Norton, K. H.; Querry, R. G.; Welch-O'Connor, R. M.; Raven, P. B.
1999-01-01
PURPOSE: Eight subjects, aged 27.0+/-1.6 yr, performed incremental workload cycling to investigate the contribution of skeletal muscle mechano- and metaboreceptors to ventilatory control during dynamic exercise. METHODS: Each subject performed four bouts of exercise: exercise with no intervention (CON); exercise with bilateral thigh cuffs inflated to 90 mm Hg (CUFF); exercise with application of lower-body positive pressure (LBPP) to 45 torr (PP); and exercise with 90 mm Hg thigh cuff inflation and 45 torr LBPP (CUFF+PP). Ventilatory responses and pulmonary gas exchange variables were collected breath-by-breath with concomitant measurement of leg intramuscular pressure. RESULTS: Ventilation (VE) was significantly elevated from CON during PP and CUFF+PP at workloads corresponding to > or = 60% CON peak oxygen uptake (VO2peak) and during CUFF at workloads > or = 80% CON VO2peak, P < 0.05. The VO2 at which ventilatory threshold occurred was significantly reduced from CON (2.17+/-0.28 L x min(-1)) to 1.60+/-0.19 L x min(-1), 1.45+/-0.15 L x min(-1), and 1.15+/-0.11 L x min(-1) during CUFF, PP, and CUFF+PP, respectively. The slope of the linear regression describing the VE/CO2 output relationship was increased from CON by approximately 22% during CUFF, 40% during PP, and 41% during CUFF+PP. CONCLUSIONS: As intramuscular pressure was significantly elevated immediately upon application of LBPP during PP and CUFF+PP without a concomitant increase in VE, it seems unlikely that LBPP-induced increases in VE can be attributed to activation of the mechanoreflex. These findings suggest that LBPP-induced reductions in perfusion pressure and decreases in venous outflow resulting from inflation of bilateral thigh cuffs may generate a metabolite sensitive intramuscular ventilatory stimulus.
Hsu, Jason E; Tang, Anna; Matsen, Frederick A
2017-11-01
The rationale for rotator cuff repair surgery is that better integrity of the cuff should be associated with better comfort and function. However, in patients with cuff disease, there is not good evidence that the degree of rotator cuff integrity is closely associated with the shoulder's comfort, function, or active motion. The goal of this study was to explore these relationships in shoulders with surgically documented cuff disease. In 55 shoulders having surgery for cuff-related symptoms, we correlated the preoperative Simple Shoulder Test score with the objectively measured preoperative active shoulder motion and with the integrity of the cuff observed at surgery. The 16 shoulders with tendinosis or partial-thickness tears had an average Simple Shoulder Test score of 3.7 ± 3.3, active abduction of 111° ± 38°, and active flexion of 115° ± 36°. The corresponding values were 3.6 ± 2.8, 94° ± 47°, and 94° ± 52° for the 22 full-thickness supraspinatus tears and 3.9 ± 2.7, 89° ± 39°, and 100° ± 39° for the 17 supraspinatus and infraspinatus tears. In this study, surgically observed cuff integrity was not strongly associated with the shoulder's comfort or function. Whereas surgeons often seek to improve the integrity of the rotator cuff, the management of patients with rotator cuff disorders needs to be informed by a better understanding of the factors other than cuff integrity that influence the comfort and functioning of shoulders with cuff disease. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Paré, Jessica; Froehlich, John E
2017-01-01
Context Recent advances within the field of genetics are currently changing many of the methodologies in which medicine is practiced. These advances are also beginning to influence the manner in which physical therapy services are rendered. Rotator cuff pathology is one of the most common diagnoses treated by the sports physical therapist. The purpose of this commentary is to educate sports physical therapists on the recent advances regarding how genetics influences rotator cuff pathology, including rotator cuff tears, and provide a perspective on how this information will likely influence post-operative shoulder rehabilitation in the near future. Evidence Acquisition A comprehensive review of the literature was completed using the Medline database along with individual searches of relevant physical therapy, surgical, cell biology, and sports medicine journals. Search terms included: shoulder, rotator cuff pathology, genetics, apoptosis, and physical therapy. Search results were compiled and evaluated; relevant primary studies and review articles were gathered; the results from this comprehensive review are summarized here. Study Design Clinical Commentary, Review of the Literature Results Recent advances within the understanding of rotator cuff pathology have further elucidated the cellular and molecular mechanisms associated with rotator cuff tears. There appears to be a hypoxic-induced apoptotic cellular pathway that contributes to rotator cuff tears. Activation of specific proteins termed matrix metalloproteinases appear to be involved in not only primary rotator cuff tears, but also may influence the re-tear rate after surgical intervention. Further advancements in the understanding of the cellular mechanisms contributing to rotator cuff tears and postoperative techniques to help prevent re-tears, may soon influence the methodology in which physical therapy services are provided to patients sustaining a rotator cuff injury. Conclusions At this time continued research is required to more fully develop a comprehensive understanding of the role of genetic variables both within primary rotator cuff tears and their influences on post-operative rehabilitation from rotator cuff repair surgery. Level of Evidence Level 5 PMID:28515982
Saline soaked pledgets prevent carbon dioxide laser-induced endotracheal tube cuff ignition.
Sosis, M B
1995-08-01
To determine whether saline soaked pledgets would protect the cuffs of polyvinylchloride (PVC) endotracheal tubes from carbon dioxide (CO2) laser-induced combustion. 12 PVC endotracheal tubes were studied. The cuffed end of each was placed in a graduated cylinder and flushed with 5 L/min of oxygen for 5 minutes. The endotracheal tube's cuff was then inflated with air and the system pressure set to 20 cm H2O. Research laboratory of a university hospital. Six of the endotracheal tube cuffs were protected with 1 inch by 3 inch saline soaked pledgets and six were left unprotected. A CO2 laser set to 40 watts was then fired at the cuffs. All six unprotected cuffs were ignited in less than 1 second. No significant combustion occurred at the six pledget protected endotracheal tube cuffs after 1 minute of laser fire. Under the conditions of this experiment, saline soaked pledgets protected PVC endotracheal tube cuffs from the CO2 laser.
Factors affecting rotator cuff healing.
Mall, Nathan A; Tanaka, Miho J; Choi, Luke S; Paletta, George A
2014-05-07
Several studies have noted that increasing age is a significant factor for diminished rotator cuff healing, while biomechanical studies have suggested the reason for this may be an inferior healing environment in older patients. Larger tears and fatty infiltration or atrophy negatively affect rotator cuff healing. Arthroscopic rotator cuff repair, double-row repairs, performing a concomitant acromioplasty, and the use of platelet-rich plasma (PRP) do not demonstrate an improvement in structural healing over mini-open rotator cuff repairs, single-row repairs, not performing an acromioplasty, or not using PRP. There is conflicting evidence to support postoperative rehabilitation protocols using early motion over immobilization following rotator cuff repair.
From the RSNA refresher courses: US of the rotator cuff: pitfalls, limitations, and artifacts.
Rutten, Matthieu J C M; Jager, Gerrit J; Blickman, Johan G
2006-01-01
High-resolution ultrasonography (US) has gained increasing popularity as a diagnostic tool for assessment of the soft tissues in shoulder impingement syndrome. US is a powerful and accurate method for diagnosis of rotator cuff tears and other rotator cuff abnormalities, provided the examiner has a detailed knowledge of shoulder anatomy, uses a standardized examination technique, and has a thorough understanding of the potential pitfalls, limitations, and artifacts. False-positive sonographic findings of rotator cuff tears can be caused by the technique (anisotropy, transducer positioning, acoustic shadowing by the deltoid septum), by the anatomy (rotator cuff interval, supraspinatus-infraspinatus interface, musculotendinous junction, fibrocartilaginous insertion), or by disease (criteria for diagnosis of rotator cuff tears, tendon inhomogeneity, acoustic shadowing by scar tissue or calcification, rotator cuff thinning). False-negative sonographic findings of rotator cuff tears can be caused by the technique (transducer frequency, suboptimal focusing, imaging protocol, transducer handling), by the anatomy (nondiastasis of the ruptured tendon fibers, posttraumatic obscuration of landmarks), by disease (tendinosis, calcifications, synovial proliferation, granulation or scar tissue, bursal thickening, massive rotator cuff tears), or by patient factors (obesity, muscularity, limited shoulder motion). (c) RSNA, 2006.
Characteristics and Clinical Outcomes in Overhead Sports Athletes after Rotator Cuff Repair
Inui, Hiroaki; Ninomiya, Hiroki; Tanaka, Hiroshi; Nobuhara, Katsuya
2017-01-01
Rotator cuff tears in young overhead sports athletes are rare. The pathomechanism causing rotator cuff tears in young overhead athletes is different from that in aged patients. The purpose of this study was to investigate rotator cuff tear characteristics in young overhead sports athletes to reveal the pathomechanism causing these injuries. This study included 25 overhead sports athletes less than 30 years old with atraumatic rotator cuff tears necessitating repair. Rotator cuff tear characteristics were evaluated intraoperatively, including rotator cuff tear shape and injured rotator cuff tendon. Clinical outcome measures were assessed before surgery and at the final follow-up. In this study, 22 patients reported minimal to no shoulder pain and returned to sports without significant complaints at last follow-up. The isolated infraspinatus tendon was most often injured; the incidence rate of the tear at this site was 32% (8 cases). In the deceleration phase of overhead motion, the eccentric contraction force of the ISP (infraspinatus) tendon peaks and the increased load leads to injury at the ISP tendon. The pathomechanism of rotator cuff injuries in young overhead athletes might be not only internal or subacromial impingement, but also these mechanisms. PMID:28702502
Bone mineralization changes of the glenoid in shoulders with symptomatic rotator cuff tear.
Harada, Yohei; Yokoya, Shin; Akiyama, Yuji; Mochizuki, Yu; Ochi, Mitsuo; Adachi, Nobuo
2018-06-06
Computed tomography osteoabsorptiometry (CTO) is a method to analyze the stress distribution in joints by measuring the subchondral bone density. The purpose of this study was to evaluate the bone mineralization changes of the glenoid in shoulders with rotator cuff tears by CTO and to evaluate whether rotator cuff tears are associated with stress changes in the glenoid. In total, 32 patients, who were diagnosed with unilateral rotator cuff tears and underwent arthroscopic rotator cuff repair, were enrolled in this study. They underwent CT scanning of both shoulders pre-operatively and the glenoid was evaluated using CTO. Hounsfield units (HU) in seven areas of the glenoid were compared between the affected and unaffected sides. The central area of the glenoid on the affected side had significantly lower HU than on the unaffected side among all patients. Focusing on the rotator cuff tear size and the subscapularis tendon, only patients with larger cuff tears or with subscapularis tendon tears showed significantly lower HU in the central area of the affected side. This study showed a decrease in bone mineralization density in the central glenoid in shoulders with rotator cuff tear. This change was observed in the case of larger cuff tears and subscapularis tendon tears. Our results help clarify the changes in stress distribution in the shoulder joint caused by symptomatic rotator cuff tears.
Bowton, David L; Hite, R Duncan; Martin, R Shayn; Sherertz, Robert
2013-10-01
Aspiration of colonized oropharyngeal secretions is a major factor in the pathogenesis of ventilator-associated pneumonia (VAP). A tapered-cuff endotracheal tube (ETT) has been demonstrated to reduce aspiration around the cuff. Whether these properties are efficacious in reducing VAP is not known. This 2-period, investigator-initiated observational study was designed to assess the efficacy of a tapered-cuff ETT to reduce the VAP rate. All intubated, mechanically ventilated patients over the age of 18 were included. During the baseline period a standard, barrel-shaped-cuff ETT (Mallinckrodt Hi-Lo) was used. All ETTs throughout the hospital were then replaced with a tapered-cuff ETT (TaperGuard). The primary outcome variable was the incidence of VAP per 1,000 ventilator days. We included 2,849 subjects, encompassing 15,250 ventilator days. The mean ± SD monthly VAP rate was 3.29 ± 1.79/1,000 ventilator days in the standard-cuff group and 2.77 ± 2.00/1,000 ventilator days in the tapered-cuff group (P = .65). While adherence to the VAP prevention bundle was high throughout the study, bundle adherence was significantly higher during the standard-cuff period (96.5 ± 2.7%) than in the tapered-cuff period (90.3 ± 3.5%, P = .01). In the setting of a VAP rate very near the average of ICUs in the United States, and where there was high adherence to a VAP prevention bundle, the use of a tapered-cuff ETT was not associated with a reduction in the VAP rate.
Ang, Benjamin Fu Hong; Chen, Jerry Yongqiang; Yeo, William; Lie, Denny Tijauw Tjoen; Chang, Paul Chee Cheng
2018-01-01
The aim of our study is to compare the improvement in clinical outcomes after conventional arthroscopic double-row rotator cuff repair and arthroscopic undersurface rotator cuff repair. A consecutive series of 120 patients who underwent arthroscopic rotator cuff repair was analysed. Sixty-one patients underwent conventional double-row rotator cuff repair and 59 patients underwent undersurface rotator cuff repair. Several clinical outcomes, including numerical pain rating scale (NPRS), constant shoulder score (CSS), Oxford shoulder score (OSS) and University of California Los Angeles shoulder score (UCLASS), were prospectively recorded by a trained healthcare professional preoperatively and at 3, 6, 12 and 24 months after surgery. Comparing both groups, there were no differences in age, gender and preoperative NPRS, CSS, OSS and UCLASS. However, the tear size was 0.7 ± 0.2 (95% confidence interval (CI) 0.3-1.1) cm larger in the conventional group ( p = 0.002). There was no difference in the improvement of NPRS, CSS, OSS and UCLASS at all time points of follow-up, that is, at 3, 6, 12 and 24 months after surgery. The duration of operation was shorter by 35 ± 3 (95% CI 28-42) min in the undersurface group ( p < 0.001). Both arthroscopic undersurface rotator cuff repair and conventional arthroscopic double-row rotator cuff repair showed marked improvements in clinical scores when compared preoperatively, and there was no difference in improvements between both groups. Arthroscopic undersurface rotator cuff repair is a faster technique compared to the conventional arthroscopic double-row rotator cuff repair.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nerve cuff. 882.5275 Section 882.5275 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5275 Nerve cuff. (a) Identification. A nerve cuff...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nerve cuff. 882.5275 Section 882.5275 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5275 Nerve cuff. (a) Identification. A nerve cuff...
21 CFR 870.1120 - Blood pressure cuff.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...
21 CFR 870.1120 - Blood pressure cuff.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...
21 CFR 870.1120 - Blood pressure cuff.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...
21 CFR 870.1120 - Blood pressure cuff.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...
Hubble space telescope observations and geometric models of compact multipolar planetary nebulae
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsia, Chih-Hao; Chau, Wayne; Zhang, Yong
2014-05-20
We report high angular resolution Hubble Space Telescope observations of 10 compact planetary nebulae (PNs). Many interesting internal structures, including multipolar lobes, arcs, two-dimensional rings, tori, and halos, are revealed for the first time. These results suggest that multipolar structures are common among PNs, and these structures develop early in their evolution. From three-dimensional geometric models, we have determined the intrinsic dimensions of the lobes. Assuming the lobes are the result of interactions between later-developed fast winds and previously ejected asymptotic giant branch winds, the geometric structures of these PNs suggest that there are multiple phases of fast winds separatedmore » by temporal variations and/or directional changes. A scenario of evolution from lobe-dominated to cavity-dominated stages is presented. The results reported here will provide serious constraints on any dynamical models of PNs.« less
A parity-breaking electronic nematic phase transition in the spin-orbit coupled metal Cd 2Re 2O 7
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harter, J. W.; Zhao, Z. Y.; Yan, J. -Q.
Strong electron interactions can drive metallic systems toward a variety of well-known symmetry-broken phases, but the instabilities of correlated metals with strong spin-orbit coupling have only recently begun to be explored. We uncovered a multipolar nematic phase of matter in the metallic pyrochlore Cd 2Re 2O 7 using spatially resolved second-harmonic optical anisotropy measurements. Like previously discovered electronic nematic phases, this multipolar phase spontaneously breaks rotational symmetry while preserving translational invariance. However, it has the distinguishing property of being odd under spatial inversion, which is allowed only in the presence of spin-orbit coupling. By examining the critical behavior of themore » multipolar nematic order parameter, we show that it drives the thermal phase transition near 200 kelvin in Cd 2Re 2O 7 and induces a parity-breaking lattice distortion as a secondary order.« less
A parity-breaking electronic nematic phase transition in the spin-orbit coupled metal Cd2Re2O7
NASA Astrophysics Data System (ADS)
Harter, J. W.; Zhao, Z. Y.; Yan, J.-Q.; Mandrus, D. G.; Hsieh, D.
2017-04-01
Strong electron interactions can drive metallic systems toward a variety of well-known symmetry-broken phases, but the instabilities of correlated metals with strong spin-orbit coupling have only recently begun to be explored. We uncovered a multipolar nematic phase of matter in the metallic pyrochlore Cd2Re2O7 using spatially resolved second-harmonic optical anisotropy measurements. Like previously discovered electronic nematic phases, this multipolar phase spontaneously breaks rotational symmetry while preserving translational invariance. However, it has the distinguishing property of being odd under spatial inversion, which is allowed only in the presence of spin-orbit coupling. By examining the critical behavior of the multipolar nematic order parameter, we show that it drives the thermal phase transition near 200 kelvin in Cd2Re2O7 and induces a parity-breaking lattice distortion as a secondary order.
Jiang, Hua; Wang, Fen-Fei; Wu, Yu-Ting; Zhou, Xi; Huang, Xue-Yong; Zhu, Jun; Gao, Ju-Fang; Dong, Rui-Bin; Cao, Kai-Ming; Yang, Zhong-Nan
2009-09-01
The spindle is essential for chromosome segregation during meiosis, but the molecular mechanism of meiotic spindle organization in higher plants is still not well understood. Here, we report on the identification and characterization of a plant-specific protein, MULTIPOLAR SPINDLE 1 (MPS1), which is involved in spindle organization in meiocytes of Arabidopsis thaliana. The homozygous mps1 mutant exhibits male and female sterility. Light microscopy showed that mps1 mutants produced multiple uneven spores during anther development, most of which aborted in later stages. Cytological analysis showed that chromosome segregation was abnormal in mps1 meiocytes. Immunolocalization showed unequal bipolar or multipolar spindles in mps1 meiocytes, which indicated that aberrant spindles resulted in disordered chromosome segregation. MPS1 encodes a 377-amino-acid protein with putative coiled-coil motifs. In situ hybridization analysis showed that MPS1 is strongly expressed in meiocytes.
On macromolecular refinement at subatomic resolution withinteratomic scatterers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Afonine, Pavel V.; Grosse-Kunstleve, Ralf W.; Adams, Paul D.
2007-11-09
A study of the accurate electron density distribution in molecular crystals at subatomic resolution, better than {approx} 1.0 {angstrom}, requires more detailed models than those based on independent spherical atoms. A tool conventionally used in small-molecule crystallography is the multipolar model. Even at upper resolution limits of 0.8-1.0 {angstrom}, the number of experimental data is insufficient for the full multipolar model refinement. As an alternative, a simpler model composed of conventional independent spherical atoms augmented by additional scatterers to model bonding effects has been proposed. Refinement of these mixed models for several benchmark datasets gave results comparable in quality withmore » results of multipolar refinement and superior of those for conventional models. Applications to several datasets of both small- and macro-molecules are shown. These refinements were performed using the general-purpose macromolecular refinement module phenix.refine of the PHENIX package.« less
On macromolecular refinement at subatomic resolution with interatomic scatterers
Afonine, Pavel V.; Grosse-Kunstleve, Ralf W.; Adams, Paul D.; Lunin, Vladimir Y.; Urzhumtsev, Alexandre
2007-01-01
A study of the accurate electron-density distribution in molecular crystals at subatomic resolution (better than ∼1.0 Å) requires more detailed models than those based on independent spherical atoms. A tool that is conventionally used in small-molecule crystallography is the multipolar model. Even at upper resolution limits of 0.8–1.0 Å, the number of experimental data is insufficient for full multipolar model refinement. As an alternative, a simpler model composed of conventional independent spherical atoms augmented by additional scatterers to model bonding effects has been proposed. Refinement of these mixed models for several benchmark data sets gave results that were comparable in quality with the results of multipolar refinement and superior to those for conventional models. Applications to several data sets of both small molecules and macromolecules are shown. These refinements were performed using the general-purpose macromolecular refinement module phenix.refine of the PHENIX package. PMID:18007035
On macromolecular refinement at subatomic resolution with interatomic scatterers.
Afonine, Pavel V; Grosse-Kunstleve, Ralf W; Adams, Paul D; Lunin, Vladimir Y; Urzhumtsev, Alexandre
2007-11-01
A study of the accurate electron-density distribution in molecular crystals at subatomic resolution (better than approximately 1.0 A) requires more detailed models than those based on independent spherical atoms. A tool that is conventionally used in small-molecule crystallography is the multipolar model. Even at upper resolution limits of 0.8-1.0 A, the number of experimental data is insufficient for full multipolar model refinement. As an alternative, a simpler model composed of conventional independent spherical atoms augmented by additional scatterers to model bonding effects has been proposed. Refinement of these mixed models for several benchmark data sets gave results that were comparable in quality with the results of multipolar refinement and superior to those for conventional models. Applications to several data sets of both small molecules and macromolecules are shown. These refinements were performed using the general-purpose macromolecular refinement module phenix.refine of the PHENIX package.
A parity-breaking electronic nematic phase transition in the spin-orbit coupled metal Cd 2Re 2O 7
Harter, J. W.; Zhao, Z. Y.; Yan, J. -Q.; ...
2017-04-21
Strong electron interactions can drive metallic systems toward a variety of well-known symmetry-broken phases, but the instabilities of correlated metals with strong spin-orbit coupling have only recently begun to be explored. We uncovered a multipolar nematic phase of matter in the metallic pyrochlore Cd 2Re 2O 7 using spatially resolved second-harmonic optical anisotropy measurements. Like previously discovered electronic nematic phases, this multipolar phase spontaneously breaks rotational symmetry while preserving translational invariance. However, it has the distinguishing property of being odd under spatial inversion, which is allowed only in the presence of spin-orbit coupling. By examining the critical behavior of themore » multipolar nematic order parameter, we show that it drives the thermal phase transition near 200 kelvin in Cd 2Re 2O 7 and induces a parity-breaking lattice distortion as a secondary order.« less
The Role of Platelet Rich Plasma (PRP) and Other Biologics for Rotator Cuff Repair.
Greenspoon, Joshua A; Moulton, Samuel G; Millett, Peter J; Petri, Maximilian
2016-01-01
Surgical treatment of rotator cuff tears has consistently demonstrated good clinical and functional outcomes. However, in some cases, the rotator cuff fails to heal. While improvements in rotator cuff constructs and biomechanics have been made, the role of biologics to aid healing is currently being investigated. A selective literature search was performed and personal surgical experiences are reported. Biologic augmentation of rotator cuff repairs can for example be performed wtableith platelet-rich plasma (PRP) and mesenchymal stem cells (MSCs). Clinical results on PRP application have been controversial. Application of MSCs has shown promise in animal studies, but clinical data on its effectiveness is presently lacking. The role of Matrix Metalloproteinase (MMP) inhibitors is another interesting field for potential targeted drug therapy after rotator cuff repair. Large randomized clinical studies need to confirm the benefit of these approaches, in order to eventually lower retear rates and improve clinical outcomes after rotator cuff repair.
The Burden of Craft in Arthroscopic Rotator Cuff Repair: Where Have We Been and Where We Are Going.
Burkhart, Stephen S
2015-08-01
The rather turbulent history of arthroscopic rotator cuff repair went through stages of innovation, conflict, disruption, assimilation, and transformation that might be anticipated when a new and advanced technology (arthroscopic cuff repair) displaces an entrenched but outdated discipline (open cuff repair). The transition from open to arthroscopic rotator cuff repair has been a major paradigm shift that has greatly benefited patients. However, this technical evolution/revolution has also imposed a higher "burden of craft" on the practitioners of arthroscopic rotator cuff repair. Technological advancements in surgery demand that surgeons accept this burden of craft and master the advanced technology for the benefit of their patients. This article outlines the author's involvement in the development of arthroscopic rotator cuff repair, and it also explores the surgeon's obligation to accept the burden of craft that is imposed by this discipline.
Obesity, hypertension and home sphygmomanometer cuffs.
Akpolat, Tekin
2010-08-01
Since the increasing prevalence of obesity leads to a larger mean arm circumferences in the hypertensive population and appropriate cuff size is essential for accurate measurement of blood pressure, overweight and obese patients often require automated home sphygmomanometers with large- or extra large-sized cuffs. The aims of this study were to evaluate the information about cuff size on automated upper arm home sphygmomanometer packing boxes and compare the findings with wrist device boxes. One hundred twelve different device boxes (49 automated upper arm, 5 semi-automatic, and 58 wrist) produced by 40 manufacturers were investigated. Three different types of information were observed (written, graphical, or a combination of both). There was not any information about cuff size on 49 (44%) device boxes. Most of the information expressed on the boxes was not attractive or informative for the patients. This study showed that the information regarding cuff size on most of the device boxes was obtuse and the patients are not warned sufficiently about appropriate cuff size. Physicians and health care providers should inform and train their patients about appropriate cuff size.
Mechanisms of rotator cuff tendinopathy: intrinsic, extrinsic, or both?
Seitz, Amee L; McClure, Philip W; Finucane, Sheryl; Boardman, N Douglas; Michener, Lori A
2011-01-01
The etiology of rotator cuff tendinopathy is multi-factorial, and has been attributed to both extrinsic and intrinsic mechanisms. Extrinsic factors that encroach upon the subacromial space and contribute to bursal side compression of the rotator cuff tendons include anatomical variants of the acromion, alterations in scapular or humeral kinematics, postural abnormalities, rotator cuff and scapular muscle performance deficits, and decreased extensibility of pectoralis minor or posterior shoulder. A unique extrinsic mechanism, internal impingement, is attributed to compression of the posterior articular surface of the tendons between the humeral head and glenoid and is not related to subacromial space narrowing. Intrinsic factors that contribute to rotator cuff tendon degradation with tensile/shear overload include alterations in biology, mechanical properties, morphology, and vascularity. The varied nature of these mechanisms indicates that rotator cuff tendinopathy is not a homogenous entity, and thus may require different treatment interventions. Treatment aimed at addressing mechanistic factors appears to be beneficial for patients with rotator cuff tendinopathy, however, not for all patients. Classification of rotator cuff tendinopathy into subgroups based on underlying mechanism may improve treatment outcomes. 2010 Elsevier Ltd. All rights reserved.
Gurnani, Navin; van Deurzen, Derek F P; van den Bekerom, Michel P J
2017-10-01
Nontraumatic full-thickness rotator cuff tears are commonly initially treated conservatively. If conservative treatment fails, rotator cuff repair is a viable subsequent option. The objective of the present meta-analysis is to evaluate the shoulder-specific outcomes one year after arthroscopic or mini-open rotator cuff repair of nontraumatic rotator cuff tears. A literature search was conducted in PubMed and EMBASE within the period January 2000 to January 2017. All studies measuring the clinical outcome at 12 months after nontraumatic rotator cuff repair of full-thickness rotator cuff tears were listed. We included 16 randomized controlled trials that met our inclusion criteria with a total of 1.221 shoulders. At 12 months after rotator cuff repair, the mean Constant score had increased 29.5 points; the mean American Shoulder and Elbow Score score increased by 38.6 points; mean Simple Shoulder Test score was 5.6 points; mean University of California Los Angeles score improved by 13.0 points; and finally, mean Visual Analogue Scale score decreased by 4.1 points. Based on this meta-analysis, significant improvements in the shoulder-specific indices are observed 12 months after nontraumatic arthroscopic or mini-open rotator cuff repair.
del Cotillo Fuente, M; Valls Matarín, J
2014-01-01
To quantify the hours of mechanical ventilation in patients with head of bed elevation≥30°. Determining compliance of cuff measurement every 6h. Descriptive longitudinal study. Measured: time head of bed elevation≥30°, <30° and reasons for non compliance, as well as cuff control every 6h. One hundred and seventy-two records of head of bed elevation and 584 of cuff pressure. Daily average head<30° for care or procedures: 2h (1h19'). The theoretical average number of hours that patients should remain at≥30° was 21h15' (3h) and actual 14h (5h) (P<.001). Registration of cuff was 76,7%. Cuffs between 20-30cmH2O were 75.9%. The 20% of cuff pressure were measured every 6h<20cmH2O and 33.7% when the interval was higher (P=.04). A third of the day patients are<30° without justification. Cuff pressure registration and percentage of therapeutic range are high. Control every 6h decreases the cuff with pressure<20cmH2O. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
Comparison of endotracheal tube cuff pressure values before and after training seminar.
Özcan, Ayça Tuba Dumanlı; Döğer, Cihan; But, Abdülkadir; Kutlu, Işık; Aksoy, Şemsi Mustafa
2018-06-01
It is recommended that endotracheal cuff (ETTc) pressure be between 20 and 30 cm H 2 O. In this present study, we intend to observe average cuff pressure values in our clinic and the change in these values after the training seminar. The cuff pressure values of 200 patients intubated following general anesthesia induction in the operating theatre were measured following intubation. One hundred patients whose values were measured before the training seminar held for all physician assistants, and 100 patients whose values were measured after the training seminar were regarded as Group 1 and Group 2, respectively. Cuff pressures of both groups were recorded, and the difference between them was shown. Moreover, cuff pressure values were explored according to the working period of the physician assistants. There was no significant difference between the groups in terms of age, gender and tube diameters. Statistically significant difference was found between cuff pressure values before and after the training (p < 0.001). Average pressure measure for Group I was 54 cm H 2 O, while average pressure in Group II declined to 33 cm H 2 O. It was observed that as the working period and experience of physician assistants increased, cuff pressure values decreased, however no statistically significant different was found (p < 0.375). We believe that clinical experience does not have significant effects on cuff pressure and that training seminars held at intervals would prevent high cuff pressure values and potential complications.
Liang, Fuyou; Takagi, Shu; Himeno, Ryutaro; Liu, Hao
2013-01-01
A variety of methods have been proposed to noninvasively assess arterial stiffness using single or multiple oscillometric cuffs. A common pitfall of most of such methods is that the individual-specific accuracy of assessment is not clearly known due to an insufficient understanding of the relationships between the characteristics of cuff oscillometry and cardiovascular properties. To provide a tool for quantitatively investigating such relationships, we developed a computational model of the cardiovascular system coupled with an oscillometric cuff wrapped around the left upper arm. The model was first examined by simulating the inflation-deflation process of the cuff. The simulated results reasonably reproduced the well-established characteristics of cuff oscillometry. The model was then applied to study the oscillation wave generated by a suprasystolic cuff that is currently under considerable debate regarding its validity for assessing aortic stiffness. The simulated results confirmed the experimental observations that the suprasystolic cuff oscillation wave resembles the blood pressure wave in the proximal brachial artery and is characterised by the presence of two systolic peaks. A systemic analysis on the simulation results for various cardiovascular/physiological conditions revealed that neither the time lag nor the height difference between the two peaks is a direct indicator of aortic stiffness. These findings provided useful evidence for explaining the conflicts among previous studies. Finally, it was stressed that although the emphasis of this study has been placed on a suprasystolic upper-arm cuff, the model could be employed to address more issues related to oscillometric cuffs.
Effects of asymptomatic rotator cuff pathology on in vivo shoulder motion and clinical outcomes.
Baumer, Timothy G; Dischler, Jack; Mende, Veronica; Zauel, Roger; van Holsbeeck, Marnix; Siegal, Daniel S; Divine, George; Moutzouros, Vasilios; Bey, Michael J
2017-06-01
The incidence of asymptomatic rotator cuff tears has been reported to range from 15% to 39%, but the influence of asymptomatic rotator cuff pathology on shoulder function is not well understood. This study assessed the effects of asymptomatic rotator cuff pathology on shoulder kinematics, strength, and patient-reported outcomes. A clinical ultrasound examination was performed in 46 asymptomatic volunteers (age: 60.3 ± 7.5 years) with normal shoulder function to document the condition of their rotator cuff. The ultrasound imaging identified the participants as healthy (n = 14) or pathologic (n = 32). Shoulder motion was measured with a biplane x-ray imaging system, strength was assessed with a Biodex (Biodex Medical Systems, Inc., Shirley, NY, USA), and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and visual analog scale pain scores. Compared with healthy volunteers, those with rotator cuff pathology had significantly less abduction (P = .050) and elevation (P = .041) strength, their humerus was positioned more inferiorly on the glenoid (P = .018), and the glenohumeral contact path length was longer (P = .007). No significant differences were detected in the Western Ontario Rotator Cuff Index, visual analog scale, range of motion, or acromiohumeral distance. The differences observed between the healthy volunteers and those with asymptomatic rotator cuff pathology lend insight into the changes in joint mechanics, shoulder strength, and conventional clinical outcomes associated with the early stages of rotator cuff pathology. Furthermore, these findings suggest a plausible mechanical progression of kinematic and strength changes associated with the development of rotator cuff pathology. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Talekar, C R; Udy, A A; Boots, R J; Lipman, J; Cook, D
2014-11-01
The application of tracheal cuff pressure monitoring is likely to vary between institutions. The aim of this study was therefore to review current evidence concerning this intervention in the intensive care unit (ICU) and to appraise regional practice by performing a state-wide survey. Publications for review were identified through searches of PubMed, EMBASE and Cochrane (1977 to 2014). All studies in English relevant to critical care and with complete data were included. Survey questions were developed by small-group consensus. Public and private ICUs across Queensland were contacted, with responses obtained from a representative member of the medical or nursing staff. Existing literature suggests significant variability in tracheal cuff pressure monitoring in the ICU, particularly in the applied technique, frequency of assessment and optimal intra-cuff pressures. Twenty-nine respondents completed the survey, representing 80.5% (29/36) of ICUs in Queensland. Twenty-eight out of twenty-nine respondents reported routinely monitoring tracheal cuff function, primarily employing cuff pressure measurement (26/28). Target cuff pressures varied, with 3/26 respondents aiming for 10 to 20 cmH2O, 10/26 for 21 to 25 cmH2O, and 13/26 for 26 to 30 cmH2O. Fifteen out of twenty-nine reported they had no current guideline or protocol for tracheal cuff management and only 16/29 indicated there was a dedicated area in the clinical record for reporting cuff intervention. Our results indicate that many ICUs across Queensland routinely measure tracheal cuff function, with most utilising pressure monitoring devices. Consistent with existing literature, the optimum cuff pressure remains uncertain. Most, however, considered that this should be a routine part of ICU care.
Endotracheal cuff pressure changes with change in position in neurosurgical patients.
Athiraman, UmeshKumar; Gupta, Rohit; Singh, Georgene
2015-01-01
Placement of a cuffed endotracheal tube for the administration of general anesthesia is routine. The cuff of the endotracheal tube is inflated with air to achieve an adequate seal to prevent micro-aspiration. Over inflation of the cuff can decrease the mucosal perfusion, leading to pressure necrosis and nerve palsies. Inadequate seal can lead to micro aspiration. So the cuff pressure has to be monitored and kept within the prescribed limits of 20-30 cms of water. To observe the effect of different positions on the endotracheal cuff pressure in patients undergoing neurosurgical procedures. This is an observational study conducted on 70 patients undergoing neurosurgical procedures in various positions. After intubation, the cuff pressure was checked with a cuff pressure manometer, Endotest (Teleflex Medical, Rush) and adjusted to be within the allowable pressure limits as is the routine practice. The cuff pressure was checked again at three time points after achieving the final position with the head on pins, at the end of the procedure and before extubation. Various factors such as the age, position, duration of surgery were studied. There were no major complications like aspiration, stridor or hoarseness of voice post extubation in any of the patients. A significant decline in the cuff pressures were noted from the initial supine position to extubation (P < .001) in the supine group. Also a significant decline in the cuff pressures were found in the prone group from their initial intubated supine position to all the other three corresponding time points namely after final positioning (P < .001), at the end of the procedure (P < .001) and before extubation (P < .001). Cuff pressure has to be checked after achieving the final positioning of the patient and adjusted to the prescribed limits to prevent micro aspiration.
Gene expression profiles of changes underlying different-sized human rotator cuff tendon tears.
Chaudhury, Salma; Xia, Zhidao; Thakkar, Dipti; Hakimi, Osnat; Carr, Andrew J
2016-10-01
Progressive cellular and extracellular matrix (ECM) changes related to age and disease severity have been demonstrated in rotator cuff tendon tears. Larger rotator cuff tears demonstrate structural abnormalities that potentially adversely influence healing potential. This study aimed to gain greater insight into the relationship of pathologic changes to tear size by analyzing gene expression profiles from normal rotator cuff tendons, small rotator cuff tears, and large rotator cuff tears. We analyzed gene expression profiles of 28 human rotator cuff tendons using microarrays representing the entire genome; 11 large and 5 small torn rotator cuff tendon specimens were obtained intraoperatively from tear edges, which we compared with 12 age-matched normal controls. We performed real-time polymerase chain reaction and immunohistochemistry for validation. Torn rotator cuff tendons demonstrated upregulation of a number of key genes, such as matrix metalloproteinase 3, 10, 12, 13, 15, 21, and 25; a disintegrin and metalloproteinase (ADAM) 12, 15, and 22; and aggrecan. Amyloid was downregulated in all tears. Small tears displayed upregulation of bone morphogenetic protein 5. Chemokines and cytokines that may play a role in chemotaxis were altered; interleukins 3, 10, 13, and 15 were upregulated in tears, whereas interleukins 1, 8, 11, 18, and 27 were downregulated. The gene expression profiles of normal controls and small and large rotator cuff tear groups differ significantly. Extracellular matrix remodeling genes were found to contribute to rotator cuff tear pathogenesis. Rotator cuff tears displayed upregulation of a number of matrix metalloproteinase (3, 10, 12, 13, 15, 21, and 25), a disintegrin and metalloproteinase (ADAM 12, 15, and 22) genes, and downregulation of some interleukins (1, 8, and 27), which play important roles in chemotaxis. These gene products may potentially have a role as biomarkers of failure of healing or therapeutic targets to improve tendon healing. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Dean, Benjamin John Floyd; Franklin, Sarah Louise; Murphy, Richard J; Javaid, Muhammad K; Carr, Andrew Jonathan
2014-12-01
Glucocorticoid injection (GCI) and surgical rotator cuff repair are two widely used treatments for rotator cuff tendinopathy. Little is known about the way in which medical and surgical treatments affect the human rotator cuff tendon in vivo. We assessed the histological and immunohistochemical effects of these common treatments on the rotator cuff tendon. Controlled laboratory study. Supraspinatus tendon biopsies were taken before and after treatment from 12 patients undergoing GCI and 8 patients undergoing surgical rotator cuff repair. All patients were symptomatic and none of the patients undergoing local GCI had full thickness tears of the rotator cuff. The tendon tissue was then analysed using histological techniques and immunohistochemistry. There was a significant increase in nuclei count and vascularity after rotator cuff repair and not after GCI (both p=0.008). Hypoxia inducible factor 1α (HIF-1α) and cell proliferation were only increased after rotator cuff repair (both p=0.03) and not GCI. The ionotropic N-methyl-d-aspartate receptor 1 (NMDAR1) glutamate receptor was only increased after GCI and not rotator cuff repair (p=0.016). An increase in glutamate was seen in both groups following treatment (both p=0.04), while an increase in the receptor metabotropic glutamate receptor 7 (mGluR7) was only seen after rotator cuff repair (p=0.016). The increases in cell proliferation, vascularity and HIF-1α after surgical rotator cuff repair appear consistent with a proliferative healing response, and these features are not seen after GCI. The increase in the glutamate receptor NMDAR1 after GCI raises concerns about the potential excitotoxic tendon damage that may result from this common treatment. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Differences of RNA Expression in the Tendon According to Anatomic Outcomes in Rotator Cuff Repair.
Ahn, Jin-Ok; Chung, Jin-Young; Kim, Do Hoon; Im, Wooseok; Kim, Sae Hoon
2017-11-01
Despite increased understanding of the pathophysiology of rotator cuff tears and the evolution of rotator cuff repair, healing failure remains a substantial problem. The critical roles played by biological factors have been emphasized, but little is known of the implications of gene expression profile differences at the time of repair. To document the relationship between the perioperative gene expression of healed and unhealed rotator cuffs by RNA microarray analysis. Case-control study; Level of evidence, 3. Superior (supraspinatus involvement) and posterosuperior (supraspinatus and infraspinatus involvement) tears were included in the study. Samples of rotator cuff tendons were prospectively collected during rotator cuff surgery. Three samples were harvested at the tendon ends of tears from the anterior, middle (apex), and posterior parts using an arthroscopic punch. Seven patients with an unhealed rotator cuff were matched one-to-one with patients with a healed rotator cuff by sex, age, tear size, and fatty degeneration of rotator cuff muscles. mRNA microarray analysis was used to identify genetic differences between healed and unhealed rotator cuff tendons. Gene ontology and gene association files were obtained from the Gene Ontology Consortium, and the Gene Ontology system in DAVID was used to identify enhanced biological processes. Microarray analyses identified 262 genes that were differentially expressed by at least 1.5-fold between the healed and unhealed groups. Overall, in the healed group, 103 genes were significantly downregulated, and 159 were significantly upregulated. DAVID Functional Annotation Cluster analysis showed that in the healed group, the genes most upregulated were related to the G protein-coupled receptor protein signaling pathway and to the neurological system. On the other hand, the genes most downregulated were related to immune and inflammatory responses. BMP5 was the gene most upregulated in the healed group, and the majority of downregulated genes were involved in the immune/inflammatory response. The downregulation of inflammatory response genes and the upregulation of cell differentiation genes in torn rotator cuffs at the time of surgery are related to rotator cuff healing. These results provide useful baseline information for future biological studies on rotator cuff healing.
Chung, Seok Won; Oh, Joo Han; Gong, Hyun Sik; Kim, Joon Yub; Kim, Sae Hoon
2011-10-01
The prognostic factors associated with structural outcome after arthroscopic rotator cuff repair have not yet been fully determined. The hypothesis of this study was that bone mineral density (BMD) is an important prognostic factor affecting rotator cuff healing after arthroscopic cuff repair. Cohort study; Level of evidence, 3. Among 408 patients who underwent arthroscopic repair for full-thickness rotator cuff tear between January 2004 and July 2008, 272 patients were included whose postoperative cuff integrity was verified by computed tomography arthrography (CTA) or ultrasonography (USG) and simultaneously who were evaluated by various functional outcome instruments. The mean age at the time of operation was 59.5 ± 7.9 years. Postoperative CTA or USG was performed at a mean 13.0 ± 5.1 months after surgery, and the mean follow-up period was 37.2 ± 10.0 months (range, 24-65 months). The clinical, structural, and surgery-related factors affecting cuff integrity including BMD were analyzed using both univariate and multivariate analysis. Evaluation of postoperative cuff integrity was performed by musculoskeletal radiologists who were unaware of the present study. The failure rate of rotator cuff healing was 22.8% (62 of 272). The failure rate was significantly higher in patients with lower BMD (P < .001); older age (P < .001); female gender (P = .03); larger tear size (P < .001); higher grade of fatty infiltration (FI) of the supraspinatus, infraspinatus, and subscapularis (all P < .001); diabetes mellitus (P = .02); shorter acromiohumeral distance (P < .001); and associated biceps procedure (P < .001). However, in the multivariate analysis, only BMD (P = .001), FI of the infraspinatus (P = .01), and the amount of retraction (P = .03) showed a significant relationship with cuff healing failure following arthroscopic rotator cuff repair. Bone mineral density, as well as FI of the infraspinatus and amount of retraction, was an independent determining factor affecting postoperative rotator cuff healing. Further studies with prospective, randomized, and controlled design are needed to confirm the relationship between BMD and postoperative rotator cuff healing.
[Analysis on risk factors of endotracheal cuff under inflation in mechanically ventilated patients].
Fu, You; Xi, Xiuming
2014-12-01
To investigate the prevalent condition of endotracheal cuff pressure and risk factors for under inflation. A prospective cohort study was conducted. Patients admitted to the Department of Critical Care Medicine of Fuxing Hospital Affiliated to Capital Medical University, who were intubated with a high-volume low-pressure endotracheal tube, and had undergone mechanical ventilation for at least 48 hours, were enrolled. The endotracheal cuff pressure was determined every 8 hours by a manual manometer connected to the distal edge of the valve cuff at 07 : 00, 15 : 00, and 23 : 00. Measurement of the endotracheal cuff pressure was continued until the extubation of endotracheal or tracheostomy tube, or death of the patient. According to the incidence of under inflation of endotracheal cuff, patients were divided into the incidence of under inflation lower than 25% group (lower low cuff pressure group) and higher than 25% group (higher low cuff pressure group). The possible influencing factors were evaluated in the two groups, including body mass index (BMI), size of endotracheal tube, duration of intubation, use of sedative or analgesic, number of leaving from intensive care unit (ICU), the number of turning over the patients, and aspiration of sputum. Logistic regression analysis was used to determine risk factors for under-inflation of the endotracheal cuff. During the study period, 53 patients were enrolled. There were 812 measurements, and 46.3% of them was abnormal, and 204 times (25.1%) of under inflation of endotracheal cuff were found. There were 24 patients (45.3%) in whom the incidence of under inflation rate was higher than 25%. The average of under inflation was 7 (4, 10) times. Compared with the group with lower rate of low cuff pressure, a longer time for intubation was found in group with higher rate of low cuff pressure [hours: 162 (113, 225) vs. 118 (97, 168), Z=-2.034, P=0.042]. There were no differences between the two groups in other factors, including size of endotracheal tube, the time from intubation to first measurement of endotracheal cuff pressure, number of leaving from ICU during admission, use of sedative agent or analgesic, and the number of body turning and aspiration (all P>0.05). No risk factor was found resulting from under inflation of the endotracheal cuff by logistic regression analysis. No significant difference was found in the incidence of ventilator associated pneumonia, duration of mechanical ventilation, successful rate of weaning on 28th day, or 28-day mortality after weaning from mechanical ventilation, and ICU mortality between the two groups. However, patients in the group of higher rate of low cuff pressure had a longer ICU stay compared with that in the group of lower rate of low cuff pressure group [days: 13 (8, 21) vs. 10 (6, 18), Z=-2.120, P=0.034]. Abnormal endotracheal cuff pressure is common in critically ill patients with intratracheal intubation. Duration of intubation is associated with under inflation of the cuff, and it calls for strengthening monitoring and management.
Elbes, Delphine; Magat, Julie; Govari, Assaf; Ephrath, Yaron; Vieillot, Delphine; Beeckler, Christopher; Weerasooriya, Rukshen; Jais, Pierre; Quesson, Bruno
2017-03-01
Interventional cardiac catheter mapping is routinely guided by X-ray fluoroscopy, although radiation exposure remains a significant concern. Feasibility of catheter ablation for common flutter has recently been demonstrated under magnetic resonance imaging (MRI) guidance. The benefit of catheter ablation under MRI could be significant for complex arrhythmias such as atrial fibrillation (AF), but MRI-compatible multi-electrode catheters such as Lasso have not yet been developed. This study aimed at demonstrating the feasibility and safety of using a multi-electrode catheter [magnetic resonance (MR)-compatible Lasso] during MRI for cardiac mapping. We also aimed at measuring the level of interference between MR and electrophysiological (EP) systems. Experiments were performed in vivo in sheep (N = 5) using a multi-electrode, circular, steerable, MR-compatible diagnostic catheter. The most common MRI sequences (1.5T) relevant for cardiac examination were run with the catheter positioned in the right atrium. High-quality electrograms were recorded while imaging with a maximal signal-to-noise ratio (peak-to-peak signal amplitude/peak-to-peak noise amplitude) ranging from 5.8 to 165. Importantly, MRI image quality was unchanged. Artefacts induced by MRI sequences during mapping were demonstrated to be compatible with clinical use. Phantom data demonstrated that this 10-pole circular catheter can be used safely with a maximum of 4°C increase in temperature. This new MR-compatible 10-pole catheter appears to be safe and effective. Combining MR and multipolar EP in a single session offers the possibility to correlate substrate information (scar, fibrosis) and EP mapping as well as online monitoring of lesion formation and electrical endpoint. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Garcia-Calero, Elena; Botella-Lopez, Arancha; Bahamonde, Olga; Perez-Balaguer, Ariadna; Martinez, Salvador
2016-07-01
In the mammalian telencephalon, part of the progenitor cells transition from multipolar to bipolar morphology as they invade the mantle zone. This associates with changing patterns of radial migration. However, the molecules implicated in these morphology transitions are not well known. In the present work, we analyzed the function of FoxP2 protein in this process during telencephalic development in vertebrates. We analyzed the expression of FoxP2 protein and its relation with cell morphology and migratory patterns in mouse and chicken developing striatum. We observed FoxP2 protein expressed in a gradient from the subventricular zone to the mantle layer in mice embryos. In the FoxP2 low domain cells showed multipolar migration. In the striatal mantle layer where FoxP2 protein expression is higher, cells showed locomoting migration and bipolar morphology. In contrast, FoxP2 showed a high and homogenous expression pattern in chicken striatum, thus bipolar morphology predominated. Elevation of FoxP2 in the striatal subventricular zone by in utero electroporation promoted bipolar morphology and impaired multipolar radial migration. In mouse cerebral cortex we obtained similar results. FoxP2 promotes transition from multipolar to bipolar morphology by means of gradiental expression in mouse striatum and cortex. Together these results indicate a role of FoxP2 differential expression in cell morphology control of the vertebrate telencephalon.
Abnormal mitosis triggers p53-dependent cell cycle arrest in human tetraploid cells.
Kuffer, Christian; Kuznetsova, Anastasia Yurievna; Storchová, Zuzana
2013-08-01
Erroneously arising tetraploid mammalian cells are chromosomally instable and may facilitate cell transformation. An increasing body of evidence shows that the propagation of mammalian tetraploid cells is limited by a p53-dependent arrest. The trigger of this arrest has not been identified so far. Here we show by live cell imaging of tetraploid cells generated by an induced cytokinesis failure that most tetraploids arrest and die in a p53-dependent manner after the first tetraploid mitosis. Furthermore, we found that the main trigger is a mitotic defect, in particular, chromosome missegregation during bipolar mitosis or spindle multipolarity. Both a transient multipolar spindle followed by efficient clustering in anaphase as well as a multipolar spindle followed by multipolar mitosis inhibited subsequent proliferation to a similar degree. We found that the tetraploid cells did not accumulate double-strand breaks that could cause the cell cycle arrest after tetraploid mitosis. In contrast, tetraploid cells showed increased levels of oxidative DNA damage coinciding with the p53 activation. To further elucidate the pathways involved in the proliferation control of tetraploid cells, we knocked down specific kinases that had been previously linked to the cell cycle arrest and p53 phosphorylation. Our results suggest that the checkpoint kinase ATM phosphorylates p53 in tetraploid cells after abnormal mitosis and thus contributes to proliferation control of human aberrantly arising tetraploids.
Neurons of human nucleus accumbens.
Sazdanović, Maja; Sazdanović, Predrag; Zivanović-Macuzić, Ivana; Jakovljević, Vladimir; Jeremić, Dejan; Peljto, Amir; Tosevski, Jovo
2011-08-01
Nucleus accumbens is a part of the ventral striatum also known as a drug active brain region, especially related with drug addiction. The aim of the study was to investigate the Golgi morphology of the nucleus accumbens neurons. The study was performed on the frontal and sagittal sections of 15 human brains by the Golgi Kopsch method. We classified neurons in the human nucleus accumbens according to their morphology and size into four types: type I--fusiform neurons; type II--fusiform neurons with lateral dendrite, arising from a part of the cell body; type III--pyramidal-like neuron; type IV--multipolar neuron. The medium spiny neurons, which are mostly noted regarding to the drug addictive conditions of the brain, correspond to the type IV--multipolar neurons. Two regions of human nucleus accumbens could be clearly recognized on Nissl and Golgi preparations each containing different predominant neuronal types. Central part of nucleus accumbens, core region, has a low density of impregnated neurons with predominant type III, pyramidal-like neurons, with spines on secondary branches and rare type IV, multipolar neurons. Contrary to the core, peripheral region, shell of nucleus, has a high density of impregnated neurons predominantly contained of type I and type IV--multipolar neurons, which all are rich in spines on secondary and tertiary dendritic branches. Our results indicate great morphological variability of human nucleus accumbens neurons. This requires further investigations and clarifying clinical significance of this important brain region.
The Biomechanical Role of Scaffolds in Augmented Rotator Cuff Tendon Repairs
2012-01-01
failure loads of a human dermal allograft rotator cuff augmentation. Arthroscopy 2008;24:20-4. doi:10.1016/j.arthro.2007.07.013 5. Bartolozzi A...of the cuff. J Bone Joint Surg Am 1991;73-A:982-9. 17. Ide J, Maeda S, Takagi K. A comparison of arthroscopic and open rotator cuff repair. Arthroscopy
National Trends in Surgery for Rotator Cuff Disease in Korea
2017-01-01
The objective of this study was to investigate the national trends in rotator cuff surgery in Korea and analyze hospital type-specific trends. We analyzed a nationwide database acquired from the Korean Health Insurance Review and Assessment Service (HIRA) from 2007 to 2015. International Classification of Diseases, 10th revision (ICD-10) codes, procedure codes, and arthroscopic device code were used to identify patients who underwent surgical treatment for rotator cuff disease. A total of 383,719 cases of rotator cuff surgeries were performed from 2007 to 2015. The mean annual percentage change in the age-adjusted rate of rotator cuff surgery per population of 100,000 persons rapidly increased from 2007 to 2012 (53.3%, P < 0.001), while that between 2012 to 2015 remained steady (2.3%, P = 0.34). The proportion of arthroscopic surgery among all rotator cuff surgeries steadily rose from 89.9% in 2007 to 96.8% in 2015 (P < 0.001). In terms of hospital types, the rate of rotator cuff surgery increased to the greatest degree in hospitals with 30–100 inpatient beds, and isolated acromioplasty procedure accounted for a larger proportion of the rotator cuff surgeries in small hospitals and clinics compared to large hospitals. Overall, our findings indicate that cases of rotator cuff surgery have increased rapidly recently in Korea, of which arthroscopic surgeries account for the greatest proportion. While rotator cuff surgery is a popular procedure that is commonly performed even in small hospitals, there was a difference in the component ratio of the procedure code in accordance with hospital type. PMID:28049250
Shinagawa, Kiyotsugu; Hatta, Taku; Yamamoto, Nobuyuki; Kawakami, Jun; Shiota, Yuki; Mineta, Mitsuyoshi; Itoi, Eiji
2018-05-03
Focus has recently been on the critical shoulder angle (CSA) as a factor related to rotator cuff tear and osteoarthritis (OA) in the European population. However, whether this relationship is observed in the Asian population is unclear. The correlation between the CSAs measured on anteroposterior radiographs and the presence or absence of rotator cuff tears or OA changes was assessed in 295 patients. Rotator cuff tears were diagnosed with magnetic resonance imaging or ultrasonography. OA findings were classified using the Samilson-Prieto classification. The CSAs among the patients with rotator cuff tears, OA changes, and those without pathologies were compared. Multivariable analyses were used to clarify the potential risks for these pathologies. The mean CSA with rotator cuff tear (33.9° ± 4.1°) was significantly greater than that without a rotator cuff tear (32.3° ± 4.5°; P = .002). Multivariable analysis also showed that a greater CSA had a significantly increased risk of rotator cuff tears, with the odds ratio of 1.08 per degree. OA findings showed no significant correlation to the CSAs. Our study demonstrates that the CSA is greater in those with a rotator cuff tear than in those without a tear or OA changes, which may be an independent risk factor for the incidence of rotator cuff tears in the Japanese population. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Effects of Asymptomatic Rotator Cuff Pathology On In-Vivo Shoulder Motion and Clinical Outcomes
Baumer, Timothy G.; Dischler, Jack; Mende, Veronica; Zauel, Roger; van Holsbeeck, Marnix; Siegal, Daniel S.; Divine, George; Moutzouros, Vasilios; Bey, Michael J.
2017-01-01
Background The incidence of asymptomatic rotator cuff tears has been reported to range from 15–39%, but the influence of asymptomatic rotator cuff pathology on shoulder function is not well understood. The objective of this study was to assess the effects of asymptomatic rotator cuff pathology on shoulder kinematics, strength, and patient-reported outcomes. Methods 46 asymptomatic volunteers (age: 60.3±7.5) with normal shoulder function underwent a clinical ultrasound exam to document the condition of their rotator cuff. The ultrasound imaging identified subjects as healthy (n=14) or pathologic (n=32). Shoulder motion was measured with a biplane x-ray imaging system, strength was assessed with a Biodex, and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and VAS pain scores. Results Compared to healthy subjects, the subjects with rotator cuff pathology had significantly less abduction (p=0.050) and elevation (p=0.041) strength, their humerus was positioned more inferiorly on the glenoid (p=0.018), and the glenohumeral contact path length was longer (p=0.007). No significant differences were detected in terms of WORC, VAS, ROM, or acromiohumeral distance. Discussion The differences observed between the healthy subjects and subjects with asymptomatic rotator cuff pathology lend insight into the changes in joint mechanics, shoulder strength, and conventional clinical outcomes associated with the early stages of rotator cuff pathology. Furthermore, these findings suggest a plausible mechanical progression of kinematic and strength changes associated with the development of rotator cuff pathology. Level of evidence Basic Science Study, Kinesiology PMID:28131679
Asymptomatic rotator cuff tears: Patient demographics and baseline shoulder function
Keener, Jay D.; Steger-May, Karen; Stobbs, Georgia; Yamaguchi, Ken
2010-01-01
Background The purpose of this study is to characterize the demographic features and physical function of subjects with asymptomatic rotator cuff tears and to compare their shoulder function to controls with an intact rotator cuff. Materials and Methods 196 subjects with an asymptomatic rotator cuff tear and 54 subjects with an intact rotator cuff presenting with a painful rotator cuff tear in the contralateral shoulder were enrolled. Various demographic features, shoulder function (ASES score and SST score), range of motion and strength were compared. Results The demographic features of the study and control groups were similar. Hand dominance was associated with the presence of shoulder pain (p < .05). Subjects with an intact rotator cuff had greater but clinically insignificant ASES (p < .05) and SST scores (p < .05) than those with an asymptomatic tear. No differences in functional scores, range of motion or strength were seen between partial (n=61) and full-thickness tears (n=135). Of the full-thickness tears, 36 (27%) were classified as small, 85 (63%) as medium and 14 (10%) as large tears. No differences were seen in functional scores between full-thickness tears of various sizes. Conclusions When asymptomatic, a rotator cuff tear is associated with a clinically insignificant loss of shoulder function compared to those with an intact rotator cuff. Therefore, a clinically detectable decline in shoulder function may indicate an “at-risk” asymptomatic tear. The presence of pain is important in cuff deficient shoulders for creating a measurable loss of shoulder function. Hand dominance appears to be an important risk factor for pain. PMID:21030274
Grewal, Harjeet; Varshney, Kavita; Thomas, Lee C; Kok, Jen; Shetty, Amith
2013-06-01
Blood pressure (BP) cuffs are potential vectors for transmission of multi-resistant organisms (MROs). The present study aims to determine MRO colonisation rates in BP cuffs from areas of high patient flow as an assessment of the quality of disinfection and infection control practices. BP cuffs in the ED, high dependency unit (HDU) and operating theatres (OT) were prospectively examined after routine disinfection procedures. Swabs collected from the inner and outer surfaces of BP cuffs during inter-patient intervals were plated onto replicate organism detection and counting, methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant Enterococcus (VRE) chromogenic agar plates to detect rates of bacterial, MRSA and VRE colonisation, respectively. High bacterial colonisation rates were detected in BP cuffs from all three areas. BP cuffs from OT were significantly less colonised compared with cuffs from HDU and ED; 76% versus 96% and 100% (P < 0.0001) for inner surfaces and 86% versus 98% and 100% (P < 0.0001) for outer surfaces, respectively. Equivalent or higher bacterial growth was observed on the inner surface compared with outer surface in 54%, 84% and 86% of BP cuffs from OT, HDU and ED, respectively. MRSA was detected in 3 of 150 (2%) swabs collected, but no VRE was detected. Although MRSA and VRE were infrequently isolated, current disinfection and infection control protocols need to be improved given the greater recovery of organisms from the inner compared with outer surfaces of BP cuffs. © 2013 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Kholinne, Erica; Lee, Hyun Joo; Kim, Sung Jung; Park, So Hyun; Jeon, In-Ho
2018-01-01
The aim of this study was to compare the microarchitecture of the greater tuberosity with or without rotator cuff tear and to obtain optimum location for anchor screw insertion for rotator cuff repair. Twenty-five humeral heads were harvested from 13 male cadavers of mean age 58.4 years, including 6 humeri with rotator cuff tear and 19 intact humeri. Six regions of interest (proximal, intermediate, and distal zones of the superficial and deep regions) were divided into the anterior (G1), middle (G2), and posterior (G3) areas of the greater tuberosity. Trabecular bone volume and cortical thickness were evaluated. Total trabecular bone volume was greater in subjects <50 years old than in subjects >50 years old but did not differ significantly in subjects with and without rotator cuff tear. Cortical thickness in both intact and torn rotator cuff groups was significantly greater in the proximal and intermediate zones than in the distal zone. Cortical thickness was related to anatomic location rather than age or cuff tear. The optimal location for anchor screw insertion during rotator cuff repair is either the proximal or intermediate region of the greater tuberosity. Age has more influence in terms of trabecular bone volume loss than rotator cuff integrity. Copyright © 2017. Production and hosting by Elsevier B.V.
Schröder, Femke F; Huis In't Veld, Rianne; den Otter, Lydia A; van Raak, Sjoerd M; Ten Haken, Bennie; Vochteloo, Anne J H
2018-04-01
The rate of retear after rotator cuff surgery is 17%. Magnetic resonance imaging (MRI) scans are used for confirmative diagnosis of retear. However, because of the presence of titanium suture anchors, metal artefacts on the MRI are common. The present study evaluated the diagnostic value of MRI after rotator cuff tendon surgery with respect to assessing the integrity as well as the degeneration and atrophy of the rotator cuff tendons when titanium anchors are in place. Twenty patients who underwent revision surgery of the rotator cuff as a result of a clinically suspected retear between 2013 and 2015 were included. The MRI scans of these patients were retrospectively analyzed by four specialized shoulder surgeons and compared with intra-operative findings (gold standard). Sensitivity and interobserver agreement among the surgeons in assessing retears as well as the Goutallier and Warner classification were examined. In 36% (range 15% to 50%) of the pre-operative MRI scans, the observers could not review the rotator cuff tendons. When the rotator cuff tendons were assessable, a diagnostic accuracy with a mean sensitivity of 0.84 (0.70 to 1.0) across the surgeons was found, with poor interobserver agreement (kappa = 0.12). Metal artefacts prevented accurate diagnosis from MRI scans of rotator cuff retear in 36% of the patients studied.
Preexisting Rotator Cuff Tears as a Predictor of Outcomes in National Football League Athletes.
Gibbs, Daniel B; Lynch, T Sean; Gombera, M Mustafa; Saltzman, Matthew D; Nuber, Gordon W; Schroeder, Gregory D; Labelle, Mark; Hollett, Brian P
A preexisting rotator cuff tear may affect the draft status and career performance of National Football League (NFL) players. Preexisting rotator cuff tears decrease a player's draft status, performance, and longevity in the NFL. Retrospective cohort study. Level 3. Medical reports of prospective NFL players during the NFL Scouting Combine from 2003 to 2011 were evaluated to identify players with a previous rotator cuff tear. Athletes were matched to control draftees without documented shoulder pathology by age, position, year drafted, and round drafted. Career statistics and performance scores were calculated. Between 2003 and 2011, 2965 consecutive athletes were evaluated. Forty-nine athletes had preexisting rotator cuff tears: 22 athletes underwent surgical intervention for their tear and 27 were treated nonoperatively. Those with a rotator cuff tear were significantly less likely to be drafted than those without a previous injury (55.1% vs 77.5%, P = 0.002). The 27 drafted athletes with preexisting rotator cuff tears started significantly fewer games (23.7 vs 43.0, P = 0.02) and played significantly fewer years (4.3 vs 5.7, P = 0.04) and significantly fewer games (47.1 vs 68.4, P = 0.04) than matched control athletes without rotator cuff tears. Athletes with a preexisting rotator cuff tear were less likely to be drafted and had decreased career longevity.
Editorial Commentary: Subacromial Decompression Is Unnecessary in Most Routine Rotator Cuff Repairs.
Solomon, Daniel J
2017-07-01
There is no need to perform subacromial decompression in partial bursal-sided rotator cuff repairs to obtain a good result. This, paired with the findings of previous studies of full-thickness rotator cuff repairs, suggests that extrinsic factors rarely affect the rotator cuff. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Medial-row failure after arthroscopic double-row rotator cuff repair.
Yamakado, Kotaro; Katsuo, Shin-ichi; Mizuno, Katsunori; Arakawa, Hitoshi; Hayashi, Seigaku
2010-03-01
We report 4 cases of medial-row failure after double-row arthroscopic rotator cuff repair (ARCR) without arthroscopic subacromial decompression (ASAD), in which there was pullout of mattress sutures of the medial row and knots were caught between the cuff and the greater tuberosity. Between October 2006 and January 2008, 49 patients underwent double-row ARCR. During this period, ASAD was not performed with ARCR. Revision arthroscopy was performed in 8 patients because of ongoing symptoms after the index operation. In 4 of 8 patients the medial rotator cuff failed; the tendon appeared to be avulsed at the medial row, and there were exposed knots on the bony surface of the rotator cuff footprint. It appeared that the knots were caught between the cuff and the greater tuberosity. Three retear cuffs were revised with the arthroscopic transtendon technique, and one was revised with a single-row technique after completing the tear. ASAD was performed in all patients. Three of the four patients showed improvement of symptoms and returned to their preinjury occupation. Impingement of pullout knots may be a source of pain after double-row rotator cuff repair. Copyright 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Wignall, Jamie R; Baines, Stephen J
2014-01-01
To evaluate the effect of cuff presence and cuff inflation on airway pressure in an inspiratory model of canine tracheostomy. Ex vivo experimental study. Cadaver tracheas from Beagle dogs were attached aborally to a vacuum. Airway pressure and flow rate was measured before and after placement of tracheostomy tubes. None. Adult uncuffed tubes and cuffed tracheostomy tubes (sizes 4, 6, 8, and 10) were placed within tracheas. Cuffs were investigated without inflation and at maximum cuff inflation. Airway pressure was measured at constant airflow rates at 30 and 60 L/min. At set flow rates, airway pressures of tracheostomy tubes were compared to the intact trachea. A size 4 uncuffed tracheostomy tube showed the lowest airway pressure and a size 4 cuffed trachestomy tube with inflation showed the highest airway pressures. For sizes 6, 8, and 10 tubes, the presence of a cuff with and without inflation significantly increased airway pressure. Inflation of a cuff always significantly increased airway pressure. Similar pressure is seen between sizes 4 and 6 uncuffed tubes. Cuffed tracheostomy tubes should not be used unless specifically indicated due to increased airway pressure. © Veterinary Emergency and Critical Care Society 2013.
Acromion Index in Korean Population and Its Relationship with Rotator Cuff Tears.
Kum, Dong Ho; Kim, Jun Ho; Park, Keun Min; Lee, Eun Su; Park, Yong Bok; Yoo, Jae Chul
2017-06-01
Among the many causes of rotator cuff tears, scapular morphology is associated with the accelerating degenerative process of the rotator cuff. Acromion index (AI) was previously introduced and compared in two populations. We enrolled 100 Korean patients diagnosed with full-thickness rotator cuff tears by magnetic resonance imaging and intraoperative arthroscopic findings between January and December 2013. Another 100 Korean patients with an intact rotator cuff tendon identified on magnetic resonance imaging and other shoulder diseases, such as frozen shoulder and instability, were enrolled as controls. We retrospectively compared these 100 rotator cuff tear patients (mean age, 63 years) and 100 controls (mean age, 51 years) in this study. Two independent orthopedic surgeons assessed the AI on radiographs. We performed an interobserver reliability test of the AI assessment, and then compared the AI between two groups. The measurement of the AI showed excellent reliability (intraclass correlation coefficient, 0.82). The mean AI in the rotator cuff tear group was 0.68 and it was significantly different between groups ( p <0.001, 95% confidence interval). The AI was not related to tear size. Our study showed that the AI was an effective predictive factor for rotator cuff tears in a Korean population.
Extracorporeal shock wave treatment for chronic rotator cuff tendonitis (shoulder pain).
Ho, C
2007-01-01
(1) Electrohydraulic, electromagnetic, or piezoelectric devices are used to translate energy into acoustic waves during extracorporeal shock wave treatment (ESWT) for chronic rotator cuff tendonitis (shoulder pain). The acoustic waves may help to accelerate the healing process of chronic rotator cuff tendonitis via an unknown mechanism. (2) ESWT, which is performed as an outpatient procedure, is intended to alleviate the pain due to chronic rotator cuff tendonitis. (3) Limited evidence from a German study indicates that the cost of ESWT for rotator cuff tendonitis is one-fifth to one-seventh the cost of surgical treatment, with longer recovery time and time off work in the surgical treatment group accounting for about two-thirds of the overall cost. (4) The evidence reviewed for this bulletin supports the use of high-energy ESWT for chronic calcific rotator cuff tendonitis, but not for non-calcific rotator cuff tendonitis. High-quality RCTs with larger sample sizes are needed to provide stronger evidence.
Regional Conflict and the Superiority of the Defense--Challenges for U. S. Operational Commanders.
1991-05-10
States and the USSR. In the new world order the U.S. finds itself in a leadership role within a multipolar community of nations. One outcome of this...multipolar community of nations. This is primarily because it is the only nation with the means to enforce international order or confront regional outlaws...point at Ascension Island. Such a long line of communication (LOC) was a major vulnera- bility for the British. To a certain extent, long LOCs also
Nuclear forward scattering of synchrotron radiation by 99Ru
Bessas, D.; Merkel, D. G.; Chumakov, A. I.; ...
2014-10-03
In this study, we measured nuclear forward scattering spectra utilizing the 99Ru transition, 89.571(3) keV, with a notably mixed E2/M1 multipolarity. The extension of the standard evaluation routines to include mixed multipolarity allows us to extract electric and magnetic hyperfine interactions from 99Ru-containing compounds. This paves the way for several other high-energy Mössbauer transitions, E~90 keV. Lastly, the high energy of such transitions allows for operando nuclear forward scattering studies in real devices.
Rosero, Eric B; Ozayar, Esra; Eslava-Schmalbach, Javier; Minhajuddin, Abu; Joshi, Girish P
2017-11-17
Tracheal tube cuff pressures exceeding the perfusion pressures of the tracheal mucosa have been associated with complications such as sore throat, tracheal mucosa ulcers, tracheal rupture, and subglottic stenosis. Despite appropriate inflation, many factors can increase the tracheal cuff pressure during mechanical ventilation. This prospective observational cohort study was designed to test the hypothesis that during a clinical model of decreasing respiratory compliance, the pressure within the endotracheal tube cuff will rise in direct relationship to increases in the airway pressures. Twenty-eight adult obese patients (BMI ≥30 kg/m) scheduled for elective laparoscopic gynecologic procedures were enrolled. All patients received general anesthesia utilizing endotracheal tubes with low-pressure high-volume cuffs. After baseline adjustment of the cuff pressure to 25 cm H2O, the airway pressures and endotracheal cuff pressures were continuously measured using pressure transducers connected to the anesthesia circuit and cuff pilot, respectively. Data on cuff and airway pressures, mechanical ventilation parameters, intraabdominal pressures, and degree of surgical table inclination were collected throughout the anesthetic procedure. General linear regression models with fixed and random effects were fit to assess the effect of increases in airway pressures on cuff pressure, after adjusting for covariates and the clustered structure of the data. The mean (standard deviation) age and body mass index were 42.2 (8.8) years and 37.7 (5.1) kg/m, respectively. After tracheal intubation, the cuffs were overinflated (ie, intracuff pressures >30 cm H2O) in 89% of patients. The cuff pressures significantly changed after concomitant variations in the airway pressures from a mean (standard error) value of 29.6 (1.30) cm H2O before peritoneal insufflations, to 35.6 (0.68) cm H2O after peritoneal insufflation, and to 27.8 (0.79) cm H2O after peritoneal deflation (P < .0001). The multilevel mixed regression models revealed that after controlling for clustering of the data (at the patient and study phase levels) and covariates, increased peak airway pressures were significantly associated with increased pressures within the endotracheal cuff (coefficient [95% confidence interval], 0.25 [0.14-0.36]; P < .0001). Other variables associated with increasing endotracheal cuff pressure included degree of surgical table inclination (0.08 [0.04-0.12]; P = .0003) and I:E ratio of 1:1 (4.47 [2.10-6.83]; P = .0002). This clinical model of decreased respiratory compliance in mechanically ventilated patients reveals that the pressure within the endotracheal cuff significantly changes in direct relation to changes in the airway pressures. This finding may have clinical relevance in patients requiring prolonged use of high airway pressures.
Robertson, Catherine M; Chen, Christopher T; Shindle, Michael K; Cordasco, Frank A; Rodeo, Scott A; Warren, Russell F
2012-09-01
Despite improvements in arthroscopic rotator cuff repair technique and technology, a significant rate of failed tendon healing persists. Improving the biology of rotator cuff repairs may be an important focus to decrease this failure rate. The objective of this study was to determine the mRNA biomarkers and histological characteristics of repaired rotator cuffs that healed or developed persistent defects as determined by postoperative ultrasound. Increased synovial inflammation and tendon degeneration at the time of surgery are correlated with the failed healing of rotator cuff tendons. Case-control study; Level of evidence, 3. Biopsy specimens from the subscapularis tendon, supraspinatus tendon, glenohumeral synovium, and subacromial bursa of 35 patients undergoing arthroscopic rotator cuff repair were taken at the time of surgery. Expression of proinflammatory cytokines, tissue remodeling genes, and angiogenesis factors was evaluated by quantitative real-time polymerase chain reaction. Histological characteristics of the affected tissue were also assessed. Postoperative (>6 months) ultrasound was used to evaluate the healing of the rotator cuff. General linear modeling with selected mRNA biomarkers was used to predict rotator cuff healing. Thirty patients completed all analyses, of which 7 patients (23%) had failed healing of the rotator cuff. No differences in demographic data were found between the defect and healed groups. American Shoulder and Elbow Surgeons shoulder scores collected at baseline and follow-up showed improvement in both groups, but there was no significant difference between groups. Increased expression of matrix metalloproteinase 1 (MMP-1) and MMP-9 was found in the supraspinatus tendon in the defect group versus the healed group (P = .006 and .02, respectively). Similar upregulation of MMP-9 was also found in the subscapularis tendon of the defect group (P = .001), which was consistent with the loss of collagen organization as determined by histological examination. From a general linear model, the upregulation of MMP-1 and MMP-9 was highly correlated with failed healing of the rotator cuff (R(2) = .656). The upregulation of tissue remodeling genes in the torn rotator cuff at the time of surgery provides a snapshot of the biological environment surrounding the torn rotator cuff that is closely related to the healing of repaired rotator cuffs.
Endotracheal Tube Cuff Pressures in Patients Intubated Prior to Helicopter EMS Transport.
Tennyson, Joseph; Ford-Webb, Tucker; Weisberg, Stacy; LeBlanc, Donald
2016-11-01
Endotracheal intubation is a common intervention in critical care patients undergoing helicopter emergency medical services (HEMS) transportation. Measurement of endotracheal tube (ETT) cuff pressures is not common practice in patients referred to our service. Animal studies have demonstrated an association between the pressure of the ETT cuff on the tracheal mucosa and decreased blood flow leading to mucosal ischemia and scarring. Cuff pressures greater than 30 cmH 2 O impede mucosal capillary blood flow. Multiple prior studies have recommended 30 cmH 2 O as the maximum safe cuff inflation pressure. This study sought to evaluate the inflation pressures in ETT cuffs of patients presenting to HEMS. We enrolled a convenience sample of patients presenting to UMass Memorial LifeFlight who were intubated by the sending facility or emergency medical services (EMS) agency. Flight crews measured the ETT cuff pressures using a commercially available device. Those patients intubated by the flight crew were excluded from this analysis as the cuff was inflated with the manometer to a standardized pressure. Crews logged the results on a research form, and we analyzed the data using Microsoft Excel and an online statistical analysis tool. We analyzed data for 55 patients. There was a mean age of 57 years (range 18-90). The mean ETT cuff pressure was 70 (95% CI= [61-80]) cmH 2 O. The mean lies 40 cmH 2 O above the maximum accepted value of 30 cmH 2 O (p<0.0001). Eighty-four percent (84%) of patients encountered had pressures above the recommended maximum. The most frequently recorded pressure was >120 cmH 2 O, the maximum pressure on the analog gauge. Patients presenting to HEMS after intubation by the referral agency (EMS or hospital) have ETT cuffs inflated to pressures that are, on average, more than double the recommended maximum. These patients are at risk for tracheal mucosal injury and scarring from decreased mucosal capillary blood flow. Hospital and EMS providers should use ETT cuff manometry to ensure that they inflate ETT cuffs to safe pressures.
Endotracheal Tube Cuff Pressures in Patients Intubated Prior to Helicopter EMS Transport
Tennyson, Joseph; Ford-Webb, Tucker; Weisberg, Stacy; LeBlanc, Donald
2016-01-01
Introduction Endotracheal intubation is a common intervention in critical care patients undergoing helicopter emergency medical services (HEMS) transportation. Measurement of endotracheal tube (ETT) cuff pressures is not common practice in patients referred to our service. Animal studies have demonstrated an association between the pressure of the ETT cuff on the tracheal mucosa and decreased blood flow leading to mucosal ischemia and scarring. Cuff pressures greater than 30 cmH2O impede mucosal capillary blood flow. Multiple prior studies have recommended 30 cmH2O as the maximum safe cuff inflation pressure. This study sought to evaluate the inflation pressures in ETT cuffs of patients presenting to HEMS. Methods We enrolled a convenience sample of patients presenting to UMass Memorial LifeFlight who were intubated by the sending facility or emergency medical services (EMS) agency. Flight crews measured the ETT cuff pressures using a commercially available device. Those patients intubated by the flight crew were excluded from this analysis as the cuff was inflated with the manometer to a standardized pressure. Crews logged the results on a research form, and we analyzed the data using Microsoft Excel and an online statistical analysis tool. Results We analyzed data for 55 patients. There was a mean age of 57 years (range 18–90). The mean ETT cuff pressure was 70 (95% CI= [61–80]) cmH2O. The mean lies 40 cmH2O above the maximum accepted value of 30 cmH2O (p<0.0001). Eighty-four percent (84%) of patients encountered had pressures above the recommended maximum. The most frequently recorded pressure was >120 cmH2O, the maximum pressure on the analog gauge. Conclusion Patients presenting to HEMS after intubation by the referral agency (EMS or hospital) have ETT cuffs inflated to pressures that are, on average, more than double the recommended maximum. These patients are at risk for tracheal mucosal injury and scarring from decreased mucosal capillary blood flow. Hospital and EMS providers should use ETT cuff manometry to ensure that they inflate ETT cuffs to safe pressures. PMID:27833679
Peripheral nerve recruitment curve using near-infrared stimulation
NASA Astrophysics Data System (ADS)
Dautrebande, Marie; Doguet, Pascal; Gorza, Simon-Pierre; Delbeke, Jean; Nonclercq, Antoine
2018-02-01
In the context of near-infrared neurostimulation, we report on an experimental hybrid electrode allowing for simultaneous photonic or electrical neurostimulation and for electrical recording of evoked action potentials. The electrode includes three contacts and one optrode. The optrode is an opening in the cuff through which the tip of an optical fibre is held close to the epineurium. Two contacts provide action potential recording. The remaining contact, together with a remote subcutaneous electrode, is used for electric stimulation which allows periodical assessment of the viability of the nerve during the experiment. A 1470 nm light source was used to stimulate a mouse sciatic nerve. Neural action potentials were not successfully recorded because of the electrical noise so muscular activity was used to reflect the motor fibres stimulation. A recruitment curve was obtained by stimulating with photonic pulses of same power and increasing duration and recording the evoked muscular action potentials. Motor fibres can be recruited with radiant exposures between 0.05 and 0.23 J/cm2 for pulses in the 100 to 500 μs range. Successful stimulation at short duration and at a commercial wavelength is encouraging in the prospect of miniaturisation and practical applications. Motor fibres recruitment curve is a first step in an ongoing research work. Neural action potential acquisition will be improved, with aim to shed light on the mechanism of action potential initiation under photonic stimulation.
Gait Phase Estimation Based on Noncontact Capacitive Sensing and Adaptive Oscillators.
Zheng, Enhao; Manca, Silvia; Yan, Tingfang; Parri, Andrea; Vitiello, Nicola; Wang, Qining
2017-10-01
This paper presents a novel strategy aiming to acquire an accurate and walking-speed-adaptive estimation of the gait phase through noncontact capacitive sensing and adaptive oscillators (AOs). The capacitive sensing system is designed with two sensing cuffs that can measure the leg muscle shape changes during walking. The system can be dressed above the clothes and free human skin from contacting to electrodes. In order to track the capacitance signals, the gait phase estimator is designed based on the AO dynamic system due to its ability of synchronizing with quasi-periodic signals. After the implementation of the whole system, we first evaluated the offline estimation performance by experiments with 12 healthy subjects walking on a treadmill with changing speeds. The strategy achieved an accurate and consistent gait phase estimation with only one channel of capacitance signal. The average root-mean-square errors in one stride were 0.19 rad (3.0% of one gait cycle) for constant walking speeds and 0.31 rad (4.9% of one gait cycle) for speed transitions even after the subjects rewore the sensing cuffs. We then validated our strategy in a real-time gait phase estimation task with three subjects walking with changing speeds. Our study indicates that the strategy based on capacitive sensing and AOs is a promising alternative for the control of exoskeleton/orthosis.
Jeon, Yoon Sang; Kim, Rag Gyu; Shin, Sang-Jin
2018-05-16
The purpose of this study was to identify the tear pattern that could be anatomically repaired by preserving the remaining tendon on footprint and evaluate clinical outcomes of patients who underwent remaining tendon preserving cuff repair. Of 523 patients with full-thickness rotator cuff tears who underwent arthroscopic repair, 41 (7.8%) patients had repairable rotator cuff tear while preserving the remaining tendon. Among them, 31 patients were followed-up for more than 2 years, including 26 patients with posterior L-shaped tear and 5 patients with transtendinous tear patterns. Clinical outcomes were evaluated using ASES and Constant score, SANE score for patient satisfaction, and VAS for pain. MRI was taken for tendon integrity 6 months postoperatively. Of the 31 patients, 11 (35.5%) had previous injury history before rotator cuff tear, including 7 (26.9%) of the 26 patients with posterior L-shaped tear and 4 (80%) of the 5 patients with transtendinous tear. The average size of preoperative cuff tear was 17.8 ± 6.8 mm in anterior-to-posterior direction and 15.2 ± 5.1 mm in medial-to-lateral direction. ASES and Constant score, SANE score, and VAS for pain were significantly (p < 0.001) improved after remaining tendon preserving rotator cuff repair. Rotator cuff tendons of 22(84.6%) patients with posterior L-shaped tear and 4(80%) patients with transtendinous tear patterns were healed. Patients who underwent rotator cuff repair with preservation of the remaining tendon on the footprint obtained satisfactory functional outcomes. Rotator cuff tears in patients who had posterior L-shaped tear extending between supraspinatus and infraspinatus tendons or transtendinous tear pattern with substantial remaining tendon could be repaired using remaining tendon preserving repair technique. Anatomic reduction of torn cuff tendon without undue tension could be achieved using the remaining tendon preserving repair technique.
Huang, Shih-Wei; Wang, Wei-Te; Chou, Lin-Chuan; Liou, Tsan-Hon; Chen, Yi-Wen; Lin, Hui-Wen
Rotator cuff tears are the most common cause of shoulder disability in people older than 50years, and surgical intervention is usually required for restoring functioning. However, in patients undergoing rotator cuff repair surgery, patients with DM had poorer functional outcomes than those without DM, and hence, DM is one of the possible risks factor for rotator cut off tear. The aim of this population-based study was to investigate the relationship between DM and the risk of rotator cuff tear in patients receiving rotator cuff repair surgery. In this retrospective longitudinal population-based 7-year cohort study, we investigated the risk of rotator cuff repair surgery in patients with DM. We performed a case-control matched analysis by using data from the Taiwan Longitudinal Health Insurance Database 2005. Patients were enrolled on the basis of the International Classification of Diseases, Ninth Revision, Clinical Modification diagnostic codes for DM between January 1, 2004, and December 31, 2007. The prevalence and the adjusted hazard ratios (HRs) of a rotator cuff repair surgery in patients with and without DM were estimated according to the Cox proportional hazard regression analysis using the frailty model. The DM and non-DM cohorts comprised 58,652 patients with DM and 117,304 (1:2) patients without DM after matching for age and sex. The incidence of rotator cuff repair surgery was 41 per 100,000 and 26 per 100,000 person-years in the DM and non-DM cohorts, respectively. The HR of rotator cuff repair surgery during the follow-up period was 1.56 (95% confidence interval [CI] 1.25-1.93, p<0.001) for patients with DM. After adjustment for covariates, the adjusted HR of rotator cuff repair surgery was 1.33 (95% CI, 1.05-1.68, p<0.001) in the DM cohort. DM is an independent risk factor for rotator cuff tear repair surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
... do not have to. Activity If you had rotator cuff or other ligament or labral surgery, you need ... 2015:chap 45. Read More Frozen shoulder Osteoarthritis Rotator cuff problems Rotator cuff repair Shoulder arthroscopy Shoulder CT ...
21 CFR 868.5750 - Inflatable tracheal tube cuff.
Code of Federal Regulations, 2010 CFR
2010-04-01
... cuff. (a) Identification. An inflatable tracheal tube cuff is a device used to provide an airtight seal between a tracheal tube and a patient's trachea. (b) Classification. Class II (performance standards). ...
Managing endotracheal tube cuff pressure at altitude: a comparison of four methods.
Britton, Tyler; Blakeman, Thomas C; Eggert, John; Rodriquez, Dario; Ortiz, Heather; Branson, Richard D
2014-09-01
Ascent to altitude results in the expansion of gases in closed spaces. The management of overinflation of the endotracheal tube (ETT) cuff at altitude is critical to prevent mucosal injury. We continuously measured ETT cuff pressures during a Critical Care Air Transport Team training flight to 8,000-ft cabin pressure using four methods of cuff pressure management. ETTs were placed in a tracheal model, and mechanical ventilation was performed. In the control ETT, the cuff was inflated to 20 mm Hg to 22 mm Hg and not manipulated. The manual method used a pressure manometer to adjust pressure at cruising altitude and after landing. A PressureEasy device was connected to the pilot balloon of the third tube and set to a pressure of 20 mm Hg to 22 mm Hg. The final method filled the balloon with 10 mL of saline. Both size 8.0-mm and 7.5-mm ETT were studied during three flights. In the control tube, pressure exceeded 70 mm Hg at cruising altitude. Manual management corrected for pressure at altitude but resulted in low cuff pressures upon landing (<10 mm Hg). The PressureEasy reduced the pressure change to a maximum of 36 mm Hg, but on landing, cuff pressures were less than 15 mm Hg. Saline inflation ameliorated cuff pressure changes at altitude, but initial pressures were 40 mm Hg. None of the three methods using air inflation managed to maintain cuff pressures below those associated with tracheal damage at altitude or above pressures associated with secretion aspiration during descent. Saline inflation minimizes altitude-related alteration in cuff pressure but creates excessive pressures at sea level. New techniques need to be developed.
Verhaegen, Filip; Brys, Peter; Debeer, Philippe
2016-02-01
Arthroscopic needling of a rotator cuff calcification is a highly reliable operation in terms of pain relief and return of function. However, during the needling process, a cuff defect is created. Little is known about the evolution of this defect. We conducted a prospective, randomized controlled clinical trial to investigate the evolution of the aforementioned defect and the role of platelet-rich plasma (PRP) augmentation in this healing process. Patients were randomized to either group 1 (PRP, n = 20) or group 2 (no PRP [control group], n = 20). Patients in group 1 received a perioperative PRP infiltration at the rotator cuff defect, whereas the control group did not. Patients were assessed clinically preoperatively and postoperatively at 6 weeks, 3 and 6 months, and 1 year. The Constant score, Simple Shoulder Test, and QuickDASH (short version of Disabilities of the Arm, Shoulder and Hand questionnaire) were used as outcome measures. The evolution of the cuff defect was evaluated on sonography at 3 and 6 months and with magnetic resonance imaging after 1 year. All patients improved significantly after surgery (P < .05). There was no difference in clinical outcome or rotator cuff healing between groups. We observed a high rate of persistent rotator cuff defects after 1 year in both groups. The presence of residual cuff defects did not influence the clinical outcome. Arthroscopic needling is an operation with a predictive, good clinical outcome. We found a high rate of persistent rotator cuff defects after 1 year. This study could not identify any beneficial effect of the addition of PRP on rotator cuff healing. Level II; Randomized Controlled Trial; Treatment Study. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Davies, Michael R; Lee, Lawrence; Feeley, Brian T; Kim, Hubert T; Liu, Xuhui
2017-07-01
Previous studies have suggested that macrophage-mediated chronic inflammation is involved in the development of rotator cuff muscle atrophy and degeneration following massive tendon tears. Increased RhoA signaling has been reported in chronic muscle degeneration, such as muscular dystrophy. However, the role of RhoA signaling in macrophage infiltration and rotator muscle degeneration remains unknown. Using a previously established rat model of massive rotator cuff tears, we found RhoA signaling is upregulated in rotator cuff muscle following a massive tendon-nerve injury. This increase in RhoA expression is greatly potentiated by the administration of a potent RhoA activator, lysophosphatidic acid (LPA), and is accompanied by increased TNFα and TGF-β1 expression in rotator cuff muscle. Boosting RhoA signaling with LPA significantly worsened rotator cuff muscle atrophy, fibrosis, and fatty infiltration, accompanied with massive monocytic infiltration of rotator cuff muscles. Co-staining of RhoA and the tissue macrophage marker CD68 showed that CD68+ tissue macrophages are the dominant cell source of increased RhoA signaling in rotator cuff muscles after tendon tears. Taken together, our findings suggest that LPA-mediated RhoA signaling in injured muscle worsens the outcomes of atrophy, fibrosis, and fatty infiltration by increasing macrophage infiltraion in rotator cuff muscle. Clinically, inhibiting RhoA signaling may represent a future direction for developing new treatments to improve muscle quality following massive rotator cuff tears. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1539-1547, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Zheng, Dingchang; Pan, Fan; Murray, Alan
2013-10-01
The aim of this study was to investigate the effect of different mechanical behaviour of the brachial artery on blood pressure (BP) measurements during cuff inflation and deflation. BP measurements were taken from each of 40 participants, with three repeat sessions under three randomized cuff deflation/inflation conditions. Cuff pressure was linearly deflated and inflated at a standard rate of 2-3 mmHg/s and also linearly inflated at a fast rate of 5-6 mmHg/s. Manual auscultatory systolic and diastolic BPs, and pulse pressure (SBP, DBP, PP) were measured. Automated BPs were determined from digitally recorded cuff pressures by fitting a polynomial model to the oscillometric pulse amplitudes. The BPs from cuff deflation and inflation were then compared. Repeatable measurements between sessions and between the sequential order of inflation/deflation conditions (all P > 0.1) indicated stability of arterial mechanical behaviour with repeat measurements. Comparing BPs obtained by standard inflation with those from standard deflation, manual SBP was 2.6 mmHg lower (P < 0.01), manual DBP was 1.5 mmHg higher (P < 0.01), manual PP was 4.2 mmHg lower (P < 0.001), automated DBP was 6.7 mmHg higher (P < 0.001) and automatic PP was 7.5 mmHg lower (P < 0.001). There was no statistically significant difference for any automated BPs between fast and standard cuff inflation. The statistically significant BP differences between inflation and deflation suggest different arterial mechanical behaviour between arterial opening and closing during BP measurement. We have shown that the mechanical behaviour of the brachial artery during BP measurement differs between cuff deflation and cuff inflation.
Pulley lesions in rotator cuff tears: prevalence, etiology, and concomitant pathologies.
Hawi, Nael; Liodakis, Emmanouil; Garving, Christina; Habermeyer, Peter; Tauber, Mark
2017-08-01
This study aimed to demonstrate the prevalence of lesions in the biceps pulley complex in a representative, consecutive series of rotator cuff tears and rotator cuff interval treatments. We also analyzed associated tear pattern of rotator cuff injuries and superior labrum anterior-posterior (SLAP) lesions. We evaluated the relationships of these lesions to traumatic genesis and the prevalence of pulley lesions in revision cases. This retrospective study analyzed all pre- and intra-operative documentation on arthroscopic rotator cuff reconstructions and isolated pulley lesion treatments performed by a single surgeon over 2 consecutive years. According to Habermeyer et al., we classified cases into four groups, based on the presence of additional or related complete or partial rotator cuff tears, SLAP lesions, trauma, and primary or revision surgery. Among 382 patients with rotator cuff tears, 345 (90.3%) had an injured pulley system; 151 (43.8%) had partial tears of the rotator cuff; out of these, 106 (30.6%) were articular-sided. All of these articular-sided partial tears showed extension into the pulley complex. In 154 cases (44.6%), history of shoulder trauma was associated with the beginning of symptoms. In addition, concomitant SLAP lesions occurred in 25-62% of pulley lesions, correlating with the severity of pulley lesions. Among the 345 cases, there have been 32 (9.3%) revision cases where a pulley lesion was intra-operatively identified and addressed. Pulley complex lesions are present in 90.3% of surgically treated rotator cuff lesions, particularly in articular-sided injuries. In addition, we found a significant relationship between the incidence of SLAP lesions and the severity of pulley lesions. It seems reasonable to assume an important role of pulley system injuries in the pathogenesis of rotator cuff lesions.
Kim, Jong Ok; Lee, Jong-Ho; Kim, Kwang-Sup; Ji, Jong-Hun; Koh, Sung-Jun; Lee, Jae-Ho
2017-11-01
This study investigated the efficacy of the bridging repair using an acellular dermal matrix (ADM) and an ADM with stem cells in rabbits. Also investigated were clinical outcomes of ADM bridging repair for large to massive rotator cuff tears. ADM, with and without stem cells, was used to cover a 5- × 5-mm-sized cuff defect in 17 rabbits, and biomechanical, histologic, and immunohistochemical analyses were conducted. Also evaluated were 24 patients with large to massive rotator cuff tears after ADM bridging repair. In the biomechanical test, the normal rotator cuff, cuff with ADM plus stem cells, and cuff with ADM in the rabbit model showed a maximum load (N) of 287.3, 217.5, and 170.3 and ultimate tensile strength (N/mm 2 ) of 11.1, 8.0, and 5.2, respectively. Histologically, the cuff tendons with the ADM or ADM plus stem cells showed characteristically mature tendons as time passed. In the clinical study, the mean American Shoulder and Elbow Surgeons score improved from preoperative 50 to postoperative 83, the University of California Los Angeles Shoulder Rating Scale from 17 to 30, and the Simple Shoulder Test from 4 to 8, respectively. No further fatty deteriorations or muscle atrophy were observed on follow-up magnetic resonance imaging. A retear was found in 5 of 24 patients (21%). Bridging repair with ADM or stem cells in the rabbit model showed cellular infiltration into the graft and some evidence of neotendon formation. Clinically, ADM repair was a safe alternative that did not show any further fatty deterioration nor muscle atrophy in large to massive rotator cuff tears. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Magnitude of Interfractional Vaginal Cuff Movement: Implications for External Irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Daniel J.; Michaletz-Lorenz, Martha; Goddu, S. Murty
2012-03-15
Purpose: To quantify the extent of interfractional vaginal cuff movement in patients receiving postoperative irradiation for cervical or endometrial cancer in the absence of bowel/bladder instruction. Methods and Materials: Eleven consecutive patients with cervical or endometrial cancer underwent placement of three gold seed fiducial markers in the vaginal cuff apex as part of standard of care before simulation. Patients subsequently underwent external irradiation and brachytherapy treatment based on institutional guidelines. Daily megavoltage CT imaging was performed during each external radiation treatment fraction. The daily positions of the vaginal apex fiducial markers were subsequently compared with the original position of themore » fiducial markers on the simulation CT. Composite dose-volume histograms were also created by summing daily target positions. Results: The average ({+-} standard deviation) vaginal cuff movement throughout daily pelvic external radiotherapy when referenced to the simulation position was 16.2 {+-} 8.3 mm. The maximum vaginal cuff movement for any patient during treatment was 34.5 mm. In the axial plane the mean vaginal cuff movement was 12.9 {+-} 6.7 mm. The maximum vaginal cuff axial movement was 30.7 mm. In the craniocaudal axis the mean movement was 10.3 {+-} 7.6 mm, with a maximum movement of 27.0 mm. Probability of cuff excursion outside of the clinical target volume steadily dropped as margin size increased (53%, 26%, 4.2%, and 1.4% for 1.0, 1.5, 2.0, and 2.5 cm, respectively.) However, rectal and bladder doses steadily increased with larger margin sizes. Conclusions: The magnitude of vaginal cuff movement is highly patient specific and can impact target coverage in patients without bowel/bladder instructions at simulation. The use of vaginal cuff fiducials can help identify patients at risk for target volume excursion.« less
Lau, Arthur C W; Lam, S M; Yan, W W
2014-02-01
OBJECTIVES. To compare three endotracheal tubes for leakage across the cuff (microaspiration) under a comprehensive set of simulated clinical situations. These were the Mallinckrodt TaperGuard (Covidien, US) with a tapered polyvinyl chloride cuff; the KimVent Microcuff (Kimberly-Clark Health Care, US) with a cylindrical polyurethane cuff; and a conventional Portex (Smiths Medical International Ltd, UK) with a globular polyvinyl chloride cuff. DESIGN. A benchtop experimental study. SETTING AND MATERIALS. A silicone cylinder serving as the model trachea was intubated with each of the three endotracheal tubes, one at a time. A total of 20 mL of water were added above the cuff and leakage measured every minute for 20 minutes under five simulated mechanical ventilation scenarios, including different positive end-expiratory pressure levels, and disconnection with and without spontaneous breathing efforts. Each scenario was studied under three cuff pressures of 10, 20 and 30 cm H2O, and then repeated with the application of a continuous suction force of 200 cm H2O, and leakage measured every minute for 3 minutes. RESULTS. The outcome of interest was the cumulative amount of leakage. The Microcuff endotracheal tubes with an ultrathin polyurethane cuff consistently provided the best protection against microaspiration under all simulated clinical situations, followed by TaperGuard with a tapered cuff, and lastly Portex with a globular polyvinyl chloride cuff. Clinical scenarios associated with the greatest leakage were mechanical ventilation with zero positive end-expiratory pressure, circuit disconnection with spontaneous breathing efforts, application of suction, and a low cuff pressure. CONCLUSIONS. Microcuff endotracheal tubes outperformed TaperGuard and Portex endotracheal tubes in preventing microaspiration, which is one of the major mechanisms for ventilator-associated pneumonia.
Influence of rotator cuff tears on glenohumeral stability during abduction tasks.
Hölscher, Thomas; Weber, Tim; Lazarev, Igor; Englert, Carsten; Dendorfer, Sebastian
2016-09-01
One of the main goals in reconstructing rotator cuff tears is the restoration of glenohumeral joint stability, which is subsequently of utmost importance in order to prevent degenerative damage such as superior labral anterior posterior (SLAP) lesion, arthrosis, and malfunction. The goal of the current study was to facilitate musculoskeletal models in order to estimate glenohumeral instability introduced by muscle weakness due to cuff lesions. Inverse dynamics simulations were used to compute joint reaction forces for several static abduction tasks with different muscle weakness. Results were compared with the existing literature in order to ensure the model validity. Further arm positions taken from activities of daily living, requiring the rotator cuff muscles were modeled and their contribution to joint kinetics computed. Weakness of the superior rotator cuff muscles (supraspinatus; infraspinatus) leads to a deviation of the joint reaction force to the cranial dorsal rim of the glenoid. Massive rotator cuff defects showed higher potential for glenohumeral instability in contrast to single muscle ruptures. The teres minor muscle seems to substitute lost joint torque during several simulated muscle tears to maintain joint stability. Joint instability increases with cuff tear size. Weakness of the upper part of the rotator cuff leads to a joint reaction force closer to the upper glenoid rim. This indicates the comorbidity of cuff tears with SLAP lesions. The teres minor is crucial for maintaining joint stability in case of massive cuff defects and should be uprated in clinical decision-making. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1628-1635, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Tempelaere, Christine; Pierrart, Jérome; Lefèvre-Colau, Marie-Martine; Vuillemin, Valérie; Cuénod, Charles-André; Hansen, Ulrich; Mir, Olivier; Skalli, Wafa; Gregory, Thomas
2016-01-01
MRI is the standard methodology in diagnosis of rotator cuff diseases. However, many patients continue to have pain despite treatment, and MRI of a static unloaded shoulder seems insufficient for best diagnosis and treatment. This study evaluated if Dynamic MRI provides novel kinematic data that can be used to improve the understanding, diagnosis and best treatment of rotator cuff diseases. Dynamic MRI provided real-time 3D image series and was used to measure changes in the width of subacromial space, superior-inferior translation and anterior-posterior translation of the humeral head relative to the glenoid during active abduction. These measures were investigated for consistency with the rotator cuff diseases classifications from standard MRI. The study included: 4 shoulders with massive rotator cuff tears, 5 shoulders with an isolated full-thickness supraspinatus tear, 5 shoulders with tendinopathy and 6 normal shoulders. A change in the width of subacromial space greater than 4mm differentiated between rotator cuff diseases with tendon tears (massive cuff tears and supraspinatus tear) and without tears (tendinopathy) (p = 0.012). The range of the superior-inferior translation was higher in the massive cuff tears group (6.4mm) than in normals (3.4mm) (p = 0.02). The range of the anterior-posterior translation was higher in the massive cuff tears (9.2 mm) and supraspinatus tear (9.3 mm) shoulders compared to normals (3.5mm) and tendinopathy (4.8mm) shoulders (p = 0.05). The Dynamic MRI enabled a novel measure; 'Looseness', i.e. the translation of the humeral head on the glenoid during an abduction cycle. Looseness was better able at differentiating different forms of rotator cuff disease than a simple static measure of relative glenohumeral position.
Relationship of individual scapular anatomy and degenerative rotator cuff tears.
Moor, Beat K; Wieser, Karl; Slankamenac, Ksenija; Gerber, Christian; Bouaicha, Samy
2014-04-01
The etiology of rotator cuff disease is age related, as documented by prevalence data. Despite conflicting results, growing evidence suggests that distinct scapular morphologies may accelerate the underlying degenerative process. The purpose of the present study was to evaluate the predictive power of 5 commonly used radiologic parameters of scapular morphology to discriminate between patients with intact rotator cuff tendons and those with torn rotator cuff tendons. A pre hoc power analysis was performed to determine the sample size. Two independent readers measured the acromion index, lateral acromion angle, and critical shoulder angle on standardized anteroposterior radiographs. In addition, the acromial morphology according to Bigliani and the acromial slope were determined on true outlet views. Measurements were performed in 51 consecutive patients with documented degenerative rotator cuff tears and in an age- and sex-matched control group of 51 patients with intact rotator cuff tendons. Receiver operating characteristic analyses were performed to determine cutoff values and to assess the sensitivity and specificity of each parameter. Patients with degenerative rotator cuff tears demonstrated significantly higher acromion indices, smaller lateral acromion angles, and larger critical shoulder angles than patients with intact rotator cuffs. However, no difference was found between the acromial morphology according to Bigliani and the acromial slope. With an area under the receiver operating characteristic curve of 0.855 and an odds ratio of 10.8, the critical shoulder angle represented the strongest predictor for the presence of a rotator cuff tear. The acromion index, lateral acromion angle, and critical shoulder angle accurately predict the presence of degenerative rotator cuff tears. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Tempelaere, Christine; Pierrart, Jérome; Lefèvre-Colau, Marie-Martine; Vuillemin, Valérie; Cuénod, Charles-André; Hansen, Ulrich; Mir, Olivier; Skalli, Wafa; Gregory, Thomas
2016-01-01
Background MRI is the standard methodology in diagnosis of rotator cuff diseases. However, many patients continue to have pain despite treatment, and MRI of a static unloaded shoulder seems insufficient for best diagnosis and treatment. This study evaluated if Dynamic MRI provides novel kinematic data that can be used to improve the understanding, diagnosis and best treatment of rotator cuff diseases. Methods Dynamic MRI provided real-time 3D image series and was used to measure changes in the width of subacromial space, superior-inferior translation and anterior-posterior translation of the humeral head relative to the glenoid during active abduction. These measures were investigated for consistency with the rotator cuff diseases classifications from standard MRI. Results The study included: 4 shoulders with massive rotator cuff tears, 5 shoulders with an isolated full-thickness supraspinatus tear, 5 shoulders with tendinopathy and 6 normal shoulders. A change in the width of subacromial space greater than 4mm differentiated between rotator cuff diseases with tendon tears (massive cuff tears and supraspinatus tear) and without tears (tendinopathy) (p = 0.012). The range of the superior-inferior translation was higher in the massive cuff tears group (6.4mm) than in normals (3.4mm) (p = 0.02). The range of the anterior-posterior translation was higher in the massive cuff tears (9.2 mm) and supraspinatus tear (9.3 mm) shoulders compared to normals (3.5mm) and tendinopathy (4.8mm) shoulders (p = 0.05). Conclusion The Dynamic MRI enabled a novel measure; ‘Looseness’, i.e. the translation of the humeral head on the glenoid during an abduction cycle. Looseness was better able at differentiating different forms of rotator cuff disease than a simple static measure of relative glenohumeral position. PMID:27434235
Gastric volume rather than nutrient content inhibits food intake.
Phillips, R J; Powley, T L
1996-09-01
To evaluate the separate contributions of distension and nutrient stimulation of the stomach to the inhibition of short-term food intake and, particularly, to reassess previous analyses based on the inflatable gastrointestinal cuff, four experiments were performed. Rats equipped with pyloric cuffs and indwelling gastric catheters consumed a liquid diet ad libitum. Their consumption during short-term (30 min) feeding bout was measured after gastric infusions on cuff-open and cuff-closed trials. Animals taking meals (approximately 5 ml) with cuffs closed immediately after receiving intragastric infusions of 2.5, 5, 7.5, or 10 ml of normal saline exhibited both suppression at the smallest infusion and a dose-dependent reduction across the other volumes (experiment 1). Additionally, when the test diet concentration was varied, animals with their cuffs closed consumed a constant volume, not a constant number of calories (experiment 2). Furthermore, cuff-closed animals exhibited no more suppression to 5-ml intragastric infusions of nutrients (including, on different trials, 50 and 100% Isocal diet; 10, 20, and 40% glucose; and 40% sucrose and 40% fructose) than to the same volume of saline (experiments 3 and 4). In contrast, on cuff-open trials in which gastric contents could empty into the duodenum, these same nutrient loads were more effective (except fructose) than saline in producing suppression of food intake. In summary, although both limited gastric distension with the pylorus occluded and intestinal nutrient stimulation with the cuff open effectively reduced intake, cuff-closed gastric loads of mixed macronutrients or carbohydrate solutions of 2-8 kcal, pH from 5.8 to 6.7, and osmolarities between 117 and 2,294 mosM/kg produced only the distension-based suppression generated by the same volume of saline.
Multipolar second harmonic generation in a symmetric nonlinear metamaterial
Wolf, Omri; Campione, Salvatore; Yang, Yuanmu; ...
2017-08-14
Optical nonlinearities are intimately related to the spatial symmetry of the nonlinear media. For example, the second order susceptibility vanishes for centrosymmetric materials under the dipole approximation. The latter concept has been naturally extended to the metamaterials’ realm, sometimes leading to the (erroneous) hypothesis that second harmonic (SH) generation is negligible in highly symmetric meta-atoms. In this work we aim to show that such symmetric meta-atoms can radiate SH light efficiently. In particular, we investigate in-plane centrosymmetric meta-atom designs where the approximation for meta-atoms breaks down. In a periodic array this building block allows us to control the directionality ofmore » the SH radiation. We conclude by showing that the use of symmetry considerations alone allows for the manipulation of the nonlinear multipolar response of a meta-atom, resulting in e.g. dipolar, quadrupolar, or multipolar emission on demand. This is because the size of the meta-atom is comparable with the free-space wavelength, thus invalidating the dipolar approximation for meta-atoms.« less
NASA Astrophysics Data System (ADS)
Ivonin, D. V.; Skrunes, S.; Brekke, C.; Ivanov, A. Yu.
2016-03-01
A simple automatic multipolarization technique for discrimination of main types of thin oil films (of thickness less than the radio wave skin depth) from natural ones is proposed. It is based on a new multipolarization parameter related to the ratio between the damping in the slick of specially normalized resonant and nonresonant signals calculated using the normalized radar cross-section model proposed by Kudryavtsev et al. (2003a). The technique is tested on RADARSAT-2 copolarization (VV/HH) synthetic aperture radar images of slicks of a priori known provenance (mineral oils, e.g., emulsion and crude oil, and plant oil served to model a natural slick) released during annual oil-on-water exercises in the North Sea in 2011 and 2012. It has been shown that the suggested multipolarization parameter gives new capabilities in interpreting slicks visible on synthetic aperture radar images while allowing discrimination between mineral oil and plant oil slicks.
Multipolar second-harmonic generation by Mie-resonant dielectric nanoparticles
NASA Astrophysics Data System (ADS)
Smirnova, Daria; Smirnov, Alexander I.; Kivshar, Yuri S.
2018-01-01
By combining analytical and numerical approaches, we study resonantly enhanced second-harmonic generation by individual high-index dielectric nanoparticles made of centrosymmetric materials. Considering both bulk and surface nonlinearities, we describe second-harmonic nonlinear scattering from a silicon nanoparticle optically excited in the vicinity of the magnetic and electric dipolar resonances. We discuss the contributions of different nonlinear sources and the effect of the low-order optical Mie modes on the characteristics of the generated far field. We demonstrate that the multipolar expansion of the radiated field is dominated by dipolar and quadrupolar modes (two axially symmetric electric quadrupoles, an electric dipole, and a magnetic quadrupole) and the interference of these modes can ensure directivity of the nonlinear scattering. The developed multipolar analysis can be instructive for interpreting the far-field measurements of the nonlinear scattering and it provides prospective insights into a design of complementary metal-oxide-semiconductor compatible nonlinear nanoantennas fully integrated with silicon-based photonic circuits, as well as methods of nonlinear diagnostics.
Partial Thickness Rotator Cuff Tears: Current Concepts
Matthewson, Graeme; Beach, Cara J.; Nelson, Atiba A.; Woodmass, Jarret M.; Ono, Yohei; Boorman, Richard S.; Lo, Ian K. Y.; Thornton, Gail M.
2015-01-01
Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized. PMID:26171251
Muscle atrophy and fatty infiltration after an acute rotator cuff repair in a sheep model
Luan, Tammy; Liu, Xuhui; Easley, Jeremiah T.; Ravishankar, Bharat; Puttlitz, Christian; Feeley, Brian T.
2015-01-01
Summary Introduction rotator cuff tears (RCTs) are the most common tendon injury seen in orthopedic patients. Muscle atrophy and fatty infiltration of the muscle are crucial factors that dictate the outcome following rotator cuff surgery. Though less studied in humans, rotator cuff muscle fibrosis has been seen in animal models as well and may influence outcomes as well. The purpose of this study was to determine if the rotator cuff would develop muscle changes even in the setting of an acute repair in a sheep model. We hypothesized that fatty infiltration and fibrosis would be present even after an acute repair six months after initial surgery. Methods twelve female adult sheep underwent an acute rotator cuff tear and immediate repair on the right shoulder. The left shoulder served as a control and did not undergo a tear or a repair. Six months following acute rotator cuff repairs, sheep muscles were harvested to study atrophy, fatty infiltration, and fibrosis by histological analysis, western blotting, and reverse transcription polymerase chain reaction (RT-PCR). Results the repair group demonstrated an increase expression of muscle atrophy, fatty infiltration, and fibrosis related genes. Significantly increased adipocytes, muscle fatty infiltration, and collagen deposition was observed in rotator cuff muscles in the tendon repair group compared to the control group. Conclusions rotator cuff muscle undergoes degradation changes including fatty infiltration and fibrosis even after the tendons are repair immediately after rupture. Level of Evidence Basic Science Study. PMID:26261789
Watson, Sheri; Aguas, Marita; Bienapfl, Tracy; Colegrove, Pat; Foisy, Nancy; Jondahl, Bonnie; Yosses, Mary Beth; Yu, Larissa; Anastas, Zoe
2011-06-01
The purpose of this study was to determine if blood pressure (BP) measured in the forearm or with an extra-long BP cuff in the upper arm accurately reflects BP measured in the upper arm with an appropriately sized BP cuff in patients with large upper arm circumference. A method-comparison design was used with a convenience sample of 49 PACU patients. Noninvasive blood pressures were obtained in two different locations (forearm; upper arm) and in the upper arm with an extra-long adult and recommended large adult cuff sizes. Data were analyzed by calculating bias and precision for the BP cuff size and location and Student's t-tests, with P < .0125 considered significant. Significantly higher forearm systolic (P < .0001) and diastolic (P < .0002) BP measurements were found compared to BP obtained in the upper arm with the reference standard BP cuff. Significantly higher systolic (t(48df) = 5.38, P < .0001), but not diastolic (t(48df) = 4.11, P < .019), BP differences were found for BP measured with the extra-long cuff at the upper arm site compared to the upper arm, reference standard BP. Findings suggest that the clinical practice of using the forearm or an extra-long cuff in the upper arm for BP measurement in post anesthesia patients with large upper arm circumferences may result in inaccurate BP values. Copyright © 2011 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.
Recurrent rotator cuff tear: is ultrasound imaging reliable?
Gilat, Ron; Atoun, Ehud; Cohen, Ornit; Tsvieli, Oren; Rath, Ehud; Lakstein, Dror; Levy, Ofer
2018-02-02
The diagnostic workup of the painful shoulder after rotator cuff repair (RCR) can be quite challenging. The aim of this study was to assess the reliability of ultrasonography (US) for the detection of recurrent rotator cuff tears in patients with shoulder pain after RCR. We hypothesized that US for the diagnosis of recurrent rotator cuff tear after RCR would not prove to be reliable when compared with surgical arthroscopic confirmation (gold standard). In this cohort study (diagnosis), we retrospectively analyzed the data of 39 patients with shoulder pain after arthroscopic RCR who had subsequently undergone US, followed by revision arthroscopy. The rotator cuff was evaluated first using US for the presence of retears. Thereafter, revision arthroscopy was performed, and the diagnosis was either established or disproved. The sensitivity and specificity of US were assessed in reference to revision arthroscopy (gold standard). A rotator cuff retear was indicated by US in 21 patients (54%) and by revision arthroscopy in 26 patients (67%). US showed a sensitivity of 80.8% and specificity of 100% in the diagnosis of rotator cuff retears. Omission of partial rotator cuff retears resulted in a spike in sensitivity to 94.7%, with 100% specificity remaining. US imaging is a highly sensitive and specific test for the detection of recurrent rotator cuff tears, as confirmed by revision arthroscopy, in patients with a painful shoulder after primary RCR. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Iwata, Eiichiro; Shigematsu, Hideki; Inoue, Kazuya; Egawa, Takuya; Tanaka, Masato; Okuda, Akinori; Morimoto, Yasuhiko; Masuda, Keisuke; Yamamoto, Yusuke; Sakamoto, Yoshihiro; Koizumi, Munehisa; Tanaka, Yasuhito
2018-02-01
Case-control study. The aim of the present study was to identify physical findings useful for differentiating between cervical spondylotic amyotrophy (CSA) and rotator cuff tears to prevent the misdiagnosis of CSA as a rotator cuff tear. CSA and rotator cuff tears are often confused among patients presenting with difficulty in shoulder elevation. Twenty-five patients with CSA and 27 with rotator cuff tears were enrolled. We included five physical findings specific to CSA that were observed in both CSA and rotator cuff tear patients. The findings were as follows: (1) weakness of the deltoid muscle, (2) weakness of the biceps muscle, (3) atrophy of the deltoid muscle, (4) atrophy of the biceps muscle, and (5) swallow-tail sign (assessment of the posterior fibers of the deltoid). Among 25 CSA patients, 10 (40.0%) were misdiagnosed with a rotator cuff tear on initial diagnosis. The sensitivity and specificity of each physical finding were as follows: (1) deltoid weakness (sensitivity, 92.0%; specificity, 55.6%), (2) biceps weakness (sensitivity, 80.0%; specificity, 100%), (3) deltoid atrophy (sensitivity, 96.0%; specificity, 77.8%), (4) biceps atrophy (sensitivity, 88.8%; specificity, 92.6%), and (5) swallow-tail sign (sensitivity, 56.0%; specificity, 74.1%). There were statistically significant differences in each physical finding. CSA is likely to be misdiagnosed as a rotator cuff tear; however, weakness and atrophy of the biceps are useful findings for differentiating between CSA and rotator cuff tears to prevent misdiagnosis.
Gellhorn, Alfred C; Gillenwater, Cody; Mourad, Pierre D
2015-09-01
The objective of this preliminary study was to evaluate the ability of individual 0.1-s long pulses of intense focused ultrasound (iFU) emitted with a carrier frequency of 2 MHz to evoke diagnostic sensations when applied to patients whose shoulders have rotator cuff tears or tendinopathy. Patients were adults with painful shoulders and clinical and imaging findings consistent with rotator cuff disease. iFU stimulation of the shoulder was performed using B-mode ultrasound coupled with a focused ultrasound transducer that allowed image-guided delivery of precisely localized pulses of energy to different anatomic areas around the rotator cuff. The main outcome measure was iFU spatial average-temporal average intensity (I_SATA), and location required to elicit sensation. In control patients, iFU produced no sensation throughout the range of stimulation intensities (≤2000 W/cm(2) I_SATA). In patients with rotator cuff disease, iFU was able to induce sensation in the tendons of the rotator cuff, the subacromial bursa, and the subchondral bone in patients with chronic shoulder pain and rotator cuff disease, with an average ± standard deviation intensity equaling 680 ± 281 W/cm(2) I_SATA. This result suggests a primary role for these tissues in the pathogenesis of shoulder pain related to rotator cuff tendinopathy. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Rehabilitation after Rotator Cuff Repair.
Nikolaidou, Ourania; Migkou, Stefania; Karampalis, Christos
2017-01-01
Rotator cuff tears are a very common condition that is often incapacitating. Whether non-surgical or surgical, successful management of rotator cuff disease is dependent on appropriate rehabilitation. If conservative management is insufficient, surgical repair is often indicated. Postsurgical outcomes for patients having had rotator cuff repair can be quite good. A successful outcome is much dependent on surgical technique as it is on rehabilitation. Numerous rehabilitation protocols for the management of rotator cuff disease are based primarily on clinical experience and expert opinion. This article describes the different rehabilitation protocols that aim to protect the repair in the immediate postoperative period, minimize postoperative stiffness and muscle atrophy. A review of currently available literature on rehabilitation after arthroscopic rotator cuff tear repair was performed to illustrate the available evidence behind various postoperative treatment modalities. There were no statistically significant differences between a conservative and an accelerated rehabilitation protocol . Early passive range of motion (ROM) following arthroscopic cuff repair is thought to decrease postoperative stiffness and improve functionality. However, early aggressive rehabilitation may compromise repair integrity. The currently available literature did not identify any significant differences in functional outcomes and relative risks of re-tears between delayed and early motion in patients undergoing arthroscopic rotator cuff repairs. A gentle rehabilitation protocol with limits in range of motion and exercise times after arthroscopic rotator cuff repair would be better for tendon healing without taking any substantial risks. A close communication between the surgeon, the patient and the physical therapy team is important and should continue throughout the whole recovery process.
Akiyama, Yasuhiro; Okamoto, Shogo; Yamada, Yoji; Ishiguro, Kenji
2016-07-01
Continuous use of wearable robots can cause skin injuries beneath the cuffs of robots. To prevent such injuries, understanding the contact behavior of the cuff is important. Thus far, this contact behavior has not been studied because of the difficulty involved in measuring the slippage under the cuff. In this study, for the first time, the relative displacement, slippage, and interaction force and moment at the thigh cuff of a robot during sit-to-stand motion were measured using an instrumented cuff, which was developed for this purpose. The results indicated that the slippage and relative displacement under the cuff was uneven because of the rotation of the cuff, which suggests that the risk of skin injuries is different at different positions. Especially, the skin closer to the hip showed larger dynamism, with a maximum slippage of approximately 10 mm and a displacement of 20 mm during motion. Another important phenomenon was the individual difference among subjects. During motion, the interaction force, moment, and slippage of some subjects suddenly increased. Such behavior results in stress concentration, which increases the risk of skin injuries. These analyses are intended to understand how skin injuries are caused and to design measures to prevent such injuries.
Validity of a new feedback method for the VEMP test.
Vanspauwen, R; Wuyts, F L; Van De Heyning, P H
2006-08-01
We used a feedback method, based on a blood pressure manometer with inflatable cuff, to control the sternocleidomastoid muscle (SCM) contraction. To obtain comparable left-right VEMP responses, it is necessary (1) to determine which cuff pressures on both sides yield identical mean rectified voltage (MRV) values of the SCM contraction and (2) to apply these cuff pressures during the VEMP test. To investigate the effect of the SCM muscle contraction variability on the VEMP variables when applying the feedback method. Subjects pushed with their jaw against the hand-held inflated cuff to generate cuff pressures of subsequently 30, 40 and 50 mmHg during a MRV and VEMP measurement. When analyzing the relationship between the applied cuff pressures and the MRV values/VEMP amplitudes, we showed that (1) there was a linear relationship, (2) there was no side effect and (3) there was an interaction effect between 'side' and 'subject'. There was neither a side effect, nor an effect of the applied cuff pressure when considering the p13 latencies. As for the n23 values, there was no side effect but there was a significant difference when comparing the n23 latencies at cuff pressures of 30 vs 40 mmHg/50 mmHg.
Differences in Risk Factors for Rotator Cuff Tears between Elderly Patients and Young Patients.
Watanabe, Akihisa; Ono, Qana; Nishigami, Tomohiko; Hirooka, Takahiko; Machida, Hirohisa
2018-02-01
It has been unclear whether the risk factors for rotator cuff tears are the same at all ages or differ between young and older populations. In this study, we examined the risk factors for rotator cuff tears using classification and regression tree analysis as methods of nonlinear regression analysis. There were 65 patients in the rotator cuff tears group and 45 patients in the intact rotator cuff group. Classification and regression tree analysis was performed to predict rotator cuff tears. The target factor was rotator cuff tears; explanatory variables were age, sex, trauma, and critical shoulder angle≥35°. In the results of classification and regression tree analysis, the tree was divided at age 64. For patients aged≥64, the tree was divided at trauma. For patients aged<64, the tree was divided at critical shoulder angle≥35°. The odds ratio for critical shoulder angle≥35° was significant for all ages (5.89), and for patients aged<64 (10.3) while trauma was only a significant factor for patients aged≥64 (5.13). Age, trauma, and critical shoulder angle≥35° were related to rotator cuff tears in this study. However, these risk factors showed different trends according to age group, not a linear relationship.
Current Biomechanical Concepts for Rotator Cuff Repair
2013-01-01
For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471
Mann, Catherine; Parkinson, Neil; Bleetman, Anthony
2007-03-01
Helicopters and light (unpressurised) aircraft are used increasingly for the transport of ventilated patients. Most of these patients are ventilated through endotracheal tubes (ETTs), others through laryngeal mask airways (LMAs). The cuffs of both ETTs and LMAs inflate with increases in altitude as barometric pressure decreases (30 mbar/1000 feet). Tracheal mucosa perfusion becomes compromised at a pressure of approximately 30 cm H2O; critical perfusion pressure is 50 cm H2O. The change in dimensions of the inflated cuffs of a size 8 ETT and a size 5 LMA were measured with digital callipers at 1000 feet intervals in the unpressurised cabin of an Agusta 109 helicopter used by the Warwickshire and Northamptonshire Air Ambulance. A linear expansion in cuff dimensions as a function of altitude increase was identified. For ETTs, a formula for removal of air from the cuff with increasing altitude was calculated and is recommended for use in aeromedical transfers. This is 1/17x1.1 = 0.06 ml/1000 foot ascent/ml initial cuff inflation. The data for LMA cuff expansion failed to show significant correlation with altitude change. Further work is required to determine a similar rule of thumb for LMA cuff deflation.
Mannava, Sandeep; Plate, Johannes F; Tuohy, Christopher J; Seyler, Thorsten M; Whitlock, Patrick W; Curl, Walton W; Smith, Thomas L; Saul, Katherine R
2013-07-01
The purpose of this article is to review basic science studies using various animal models for rotator cuff research and to describe structural, biomechanical, and functional changes to muscle following rotator cuff tears. The use of computational simulations to translate the findings from animal models to human scale is further detailed. A comprehensive review was performed of the basic science literature describing the use of animal models and simulation analysis to examine muscle function following rotator cuff injury and repair in the ageing population. The findings from various studies of rotator cuff pathology emphasize the importance of preventing permanent muscular changes with detrimental results. In vivo muscle function, electromyography, and passive muscle-tendon unit properties were studied before and after supraspinatus tenotomy in a rodent rotator cuff injury model (acute vs chronic). Then, a series of simulation experiments were conducted using a validated computational human musculoskeletal shoulder model to assess both passive and active tension of rotator cuff repairs based on surgical positioning. Outcomes of rotator cuff repair may be improved by earlier surgical intervention, with lower surgical repair tensions and fewer electromyographic neuromuscular changes. An integrated approach of animal experiments, computer simulation analyses, and clinical studies may allow us to gain a fundamental understanding of the underlying pathology and interpret the results for clinical translation.
Thomas-Fermi model electron density with correct boundary conditions: Application to atoms and ions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patil, S.H.
1999-01-01
The author proposes an electron density in atoms and ions, which has the Thomas-Fermi-Dirac form in the intermediate region of r, satisfies the Kato condition for small r, and has the correct asymptotic behavior at large values of r, where r is the distance from the nucleus. He also analyzes the perturbation in the density produced by multipolar fields. He uses these densities in the Poisson equation to deduce average values of r{sup m}, multipolar polarizabilities, and dispersion coefficients of atoms and ions. The predictions are in good agreement with experimental and other theoretical values, generally within about 20%. Hemore » tabulates here the coefficient A in the asymptotic density; radial expectation values (r{sup m}) for m = 2, 4, 6; multipolar polarizabilities {alpha}{sub 1}, {alpha}{sub 2}, {alpha}{sub 3}; expectation values {l_angle}r{sup 0}{r_angle} and {l_angle}r{sup 2}{r_angle} of the asymptotic electron density; and the van der Waals coefficient C{sub 6} for atoms and ions with 2 {le} Z {le} 92. Many of the results, particularly the multipolar polarizabilities and the higher order dispersion coefficients, are the only ones available in the literature. The variation of these properties also provides interesting insight into the shell structure of atoms and ions. Overall, the Thomas-Fermi-Dirac model with the correct boundary conditions provides a good global description of atoms and ions.« less
Lee, M.W.; Meuwly, M.
2013-01-01
The evaluation of hydration free energies is a sensitive test to assess force fields used in atomistic simulations. We showed recently that the vibrational relaxation times, 1D- and 2D-infrared spectroscopies for CN(-) in water can be quantitatively described from molecular dynamics (MD) simulations with multipolar force fields and slightly enlarged van der Waals radii for the C- and N-atoms. To validate such an approach, the present work investigates the solvation free energy of cyanide in water using MD simulations with accurate multipolar electrostatics. It is found that larger van der Waals radii are indeed necessary to obtain results close to the experimental values when a multipolar force field is used. For CN(-), the van der Waals ranges refined in our previous work yield hydration free energy between -72.0 and -77.2 kcal mol(-1), which is in excellent agreement with the experimental data. In addition to the cyanide ion, we also study the hydroxide ion to show that the method used here is readily applicable to similar systems. Hydration free energies are found to sensitively depend on the intermolecular interactions, while bonded interactions are less important, as expected. We also investigate in the present work the possibility of applying the multipolar force field in scoring trajectories generated using computationally inexpensive methods, which should be useful in broader parametrization studies with reduced computational resources, as scoring is much faster than the generation of the trajectories.
NASA Astrophysics Data System (ADS)
Souza-Filho, Pedro Walfir M.; Paradella, Waldir R.; Rodrigues, Suzan W. P.; Costa, Francisco R.; Mura, José C.; Gonçalves, Fabrício D.
2011-11-01
This study assessed the use of multi-polarized L-band images for the identification of coastal wetland environments in the Amazon coast region of northern Brazil. Data were acquired with a SAR R99B sensor from the Amazon Surveillance System (SIVAM) on board a Brazilian Air Force jet. Flights took place in the framework of the 2005 MAPSAR simulation campaign, a German-Brazilian feasibility study focusing on a L-band SAR satellite. Information retrieval was based on the recognition of the interaction between a radar signal and shallow-water morphology in intertidal areas, coastal dunes, mangroves, marshes and the coastal plateau. Regarding the performance of polarizations, VV was superior for recognizing intertidal area morphology under low spring tide conditions; HH for mapping coastal environments covered with forest and scrub vegetation such as mangrove and vegetated dunes, and HV was suitable for distinguishing transition zones between mangroves and coastal plateau. The statistical results for the classification maps expressed by kappa index and general accuracy were 83.3% and 0.734 for the multi-polarized color composition (R-HH, G-HV, B-VV), 80.7% and 0.694% for HH, 79.7% and 0.673% for VV, and 77.9% and 0.645% for HV amplitude image. The results indicate that use of multi-polarized L-band SAR is a valuable source of information aiming at the identification and discrimination of distinct geomorphic targets in tropical wetlands.
Assessment and treatment strategies for rotator cuff tears
Al-Hakim, Wisam; Noorani, Ali
2014-01-01
Tears of the rotator cuff are common and becoming an increasingly frequent problem. There is a vast amount of literature on the merits and limitations of the various methods of clinical and radiological assessment of rotator cuff tears. This is also the case with regard to treatment strategies. Certain popular beliefs and principles practiced widely and the basis upon which they are derived may be prone to inaccuracy. We provide an overview of the historical management of rotator cuff tears, as well as an explanation for how and why rotator cuff tears should be managed, and propose a structured methodology for their assessment and treatment. PMID:27582960
Immobilization After Rotator Cuff Repair: What Evidence Do We Have Now?
Hsu, Jason E; Horneff, John G; Gee, Albert O
2016-01-01
Recurrent tears after rotator cuff repair are common. Postoperative rehabilitation after rotator cuff repair is a modifiable factor controlled by the surgeon that can affect re-tear rates. Some surgeons prefer early mobilization after rotator cuff repair, whereas others prefer a period of immobilization to protect the repair site. The tendon-healing process incorporates biochemical and biomechanical responses to mechanical loading. Healing can be optimized with controlled loading. Complete load removal and chronic overload can be deleterious to the process. Several randomized clinical studies have also characterized the role of postoperative mobilization after rotator cuff repair. Copyright © 2016 Elsevier Inc. All rights reserved.
Injection Therapies for Rotator Cuff Disease.
Lin, Kenneth M; Wang, Dean; Dines, Joshua S
2018-04-01
Rotator cuff disease affects a large proportion of the overall population and encompasses a wide spectrum of pathologies, including subacromial impingement, rotator cuff tendinopathy or tear, and calcific tendinitis. Various injection therapies have been used for the treatment of rotator cuff disease, including corticosteroid, prolotherapy, platelet-rich plasma, stem cells, and ultrasound-guided barbotage for calcific tendinitis. However, the existing evidence for these therapies remains controversial or sparse. Ultimately, improved understanding of the underlying structural and compositional deficiencies of the injured rotator cuff tissue is needed to identify the biological needs that can potentially be targeted with injection therapies. Copyright © 2017 Elsevier Inc. All rights reserved.
Genome-wide association study identifies a locus associated with rotator cuff injury
Roos, Thomas R.; Roos, Andrew K.; Avins, Andrew L.; Ahmed, Marwa A.; Kleimeyer, John P.; Fredericson, Michael; Ioannidis, John P. A.; Dragoo, Jason L.
2017-01-01
Rotator cuff tears are common, especially in the fifth and sixth decades of life, but can also occur in the competitive athlete. Genetic differences may contribute to overall injury risk. Identifying genetic loci associated with rotator cuff injury could shed light on the etiology of this injury. We performed a genome-wide association screen using publically available data from the Research Program in Genes, Environment and Health including 8,357 cases of rotator cuff injury and 94,622 controls. We found rs71404070 to show a genome-wide significant association with rotator cuff injury with p = 2.31x10-8 and an odds ratio of 1.25 per allele. This SNP is located next to cadherin8, which encodes a protein involved in cell adhesion. We also attempted to validate previous gene association studies that had reported a total of 18 SNPs showing a significant association with rotator cuff injury. However, none of the 18 SNPs were validated in our dataset. rs71404070 may be informative in explaining why some individuals are more susceptible to rotator cuff injury than others. PMID:29228018
The Repaired Rotator Cuff: MRI and Ultrasound Evaluation.
Lee, Susan C; Williams, Danielle; Endo, Yoshimi
2018-03-01
The purposes of this review were to provide an overview of the current practice of evaluating the postoperative rotator cuff on imaging and to review the salient imaging findings of the normal and abnormal postoperative rotator cuff, as well as of postoperative complications. The repaired rotator cuff frequently appears abnormal on magnetic resonance imaging (MRI) and ultrasound (US). Recent studies have shown that while the tendons typically normalize, they can demonstrate clinically insignificant abnormal imaging appearances for longer than 6 months. Features of capsular thickening or subacromial-subdeltoid bursal thickening and fluid distension were found to decrease substantially in the first 6-month postoperative period. MRI and US were found to be highly comparable in the postoperative assessment of the rotator cuff, although they had a lower sensitivity for partial thickness tears. Imaging evaluation of newer techniques such as patch augmentation and superior capsular reconstruction needs to be further investigated. MRI and US are useful in the postoperative assessment of the rotator cuff, not only for evaluation of the integrity of the rotator cuff, but also for detecting hardware complications and other etiologies of shoulder pain.
Severed cuff inflation tubing of endotracheal tube: A novel way to prevent cuff deflation.
Rao, Amrut K; Chaudhuri, Souvik; Joseph, Tim T; Kamble, Deependra; Gotur, Gopal; Venkatesh, Sandeep
2014-01-01
A well-secured endotracheal tube (ETT) is essential for safe anesthesia. The ETT has to be fixed with the adhesive plasters or with tie along with adhesive plasters appropriately. It is specially required in patients having beard, in intensive care unit (ICU) patients or in oral surgeries. If re-adjustment of the ETT is necessary, we should be cautious while removal of the plasters and tie, as there may be damage to the cuff inflation system. This can be a rare cause of ETT cuff leak, thus making maintenance of adequate ventilation difficult and requiring re-intubation. In a difficult airway scenario, it can be extremely challenging to re-intubate again. We report an incidence where the ETT cuff tubing was severed while attempting to re-adjust and re-fix the ETT and the patient required re-intubation. Retrospectively, we thought of and describe a safe, reliable and novel technique to prevent cuff deflation of the severed inflation tube. The technique can also be used to monitor cuff pressure in such scenarios.
Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure.
Kikuya, Masahiro; Chonan, Kenichi; Imai, Yutaka; Goto, Eiji; Ishii, Masao
2002-04-01
Self-measurement of blood pressure (BP) might offer some advantages in diagnosis and therapeutic evaluation and in patient management of hypertension. Recently, wrist-cuff devices for self-measurement of BP have gained more than one-third of the world market share. In the present study, we validated wrist-cuff devices and compared the results between wrist- and arm-cuff devices. The factors affecting the accuracy of wrist-cuff devices were also studied. The research group to assess the validity of automated blood pressure measuring device consisted of 13 institutes in Japan, which validated two wrist-cuff devices (WC-1 and WC-2) and two arm-cuff devices (AC-1 and AC-2). They used a crossover method, where the comparison was done between auscultation, by two observers by means of a double stethoscope on one arm and the device on the opposite arm or wrist. There was good inter-observer agreement for the auscultation method in each institute (systolic blood pressure (SBP), -0.1 +/- 2.8 mmHg; diastolic blood pressure (DBP), -0.1 +/- 2.6 mmHg, n = 498). The mean difference between auscultation and the device was minimal both in arm-cuff devices (mean difference for AC-1, 2.2/1.9 mmHg, n = 97 and for AC-2, 5.1/2.9 mmHg, n = 136, SBP/DBP) and wrist-cuff devices (mean difference for WC-1, -2.1/1.2 mmHg, n = 173 mmHg and for WC-2, -2.3/-5.6 mmHg, n = 92). The standard deviation of the difference (SDD) in wrist-cuff devices, however (SDD for WC-1, 9.7/7.3 mmHg and for WC-2, 10.2/8.6 mmHg), was larger than that of the arm-cuff devices (SDD for AC-1, 5.6/6.6 mmHg and for AC-2, 6.3/5.1 mmHg). Grading of AC-1 and AC-2 based on criteria of British Hypertension Society was A/A and B/A, respectively, while that of WC-1 and WC-2 was C/B and D/B, respectively. Using the same validation protocol, the results of validation for one device were divergent in each institute. In wrist-cuff devices, the BP value obtained in palmar flexion was significantly higher and that obtained in palmar dorsiflexion was significantly lower than that in palmar extension. In some cases, finger plethysmogram did not disappear during maximum inflation of the wrist-cuff (congruent with 250 mmHg), even in palmar extension and especially in palmar flexion, suggesting incomplete obstruction of radial and/or ulnar arteries during inflation. The results suggest that wrist-cuff devices in the present form are inadequate for self-measurement of blood pressure and, thus, are inadequate for general use or clinical and practical use. However, there is much possibility in wrist-cuff device and the accuracy and reliability of wrist-cuff device are warranted by an improvement of technology.
Rotator Cuff Injuries - Multiple Languages
... Are Here: Home → Multiple Languages → All Health Topics → Rotator Cuff Injuries URL of this page: https://medlineplus.gov/ ... V W XYZ List of All Topics All Rotator Cuff Injuries - Multiple Languages To use the sharing features ...
[Contribution of MRI to the preoperative evaluation of rotator cuff tears].
Gagey, N; Desmoineaux, P; Gagey, O; Idy-Peretti, I; Mazas, F
1991-01-01
The authors report a series of 38 patients who had been examined by MRI and then operated for a rotator cuff syndrome. The correlation between the description of the cuff lesions after MRI and the surgical observations were excellent for 37 patients. In one case MRI showed a false image of tear of the supra spinatus m. on its anterior edge. This was due to a bad knowledge of the anatomy of the muscle and tendon and to a poor orientation of the frontal cut plane. This study was completed with MRI and anatomic study of 12 non embalmed cadaveric shoulders. The results showed that MRI was very sensitive (0.93) and specific (0.94) for the diagnosis of rotator cuff tears. MRI allowed also to show partial tears of the tendons of the rotator cuff. The authors propose a MRI classification of cuff lesions which permits to establish a good surgical planning.
The role of platelet-rich plasma in rotator cuff repair.
Mei-Dan, Omer; Carmont, Michael R
2011-09-01
The shoulder is a common source of disability resulting from traumatic and degenerate tears of the rotator cuff, subacromial impingement, and osteoarthritis. Nonoperative management has focused on treatment of the predisposing factors, the use of analgesics and anti-inflammatory medication usually in association with local anesthetic and steroid injections. Surgical intervention allows debridement of the degenerate cuff and partial thickness cuff tears, subacromial bursitis, impinging bone spurs and osteophytes together with rotator cuff repairs. Repairs of degenerate and torn tissue are often prone to failure due to many intrinsic and extrinsic factors. It is assumed that some biological therapies might improve clinical, mechanical, and histologic outcomes. Injections of platelet-rich plasma (PRP) have led to reduced pain and improved recovery in other degenerate pathologies areas together with the restoration of function. This study reviews the current literature on PRP and in particular discusses its relevance in the treatment of rotator cuff tears.
Special report: Occlusive cuff controller
NASA Technical Reports Server (NTRS)
Baker, J. T.
1975-01-01
A mechanical occlusive cuff controller suitable for blood flow experiments in space shuttle flights is described. The device requires 115 volt ac power and a pressurized gas source. Two occluding cuff pressures (30 and 50 mmHg) are selectable by a switch on the front panel. A screw driver adjustment allows accurate cuff pressurization levels for under or oversized limbs. Two pressurization cycles (20 second and 2 minutes) can be selected by a front panel switch. Adjustment of the timing cycles is also available through the front panel. A pushbutton hand switch allows remote start of the cuff inflation cycle. A stop/reset switch permits early termination of the cycle and disabling of the controller to prevent inadvertent reactivation. Pressure in the cuff is monitored by a differential aneroid barometer. In addition, an electrocardiogram trigger circuit permits the initiation of the pressurization cycle by an externally supplied ECG cycle.
Miyazaki, Yu; Komasawa, Nobuyasu; Fujiawara, Shunsuke; Majima, Nozomi; Tatsumi, Shinichi; Minami, Toshiaki
2015-02-01
BaCKGROUND: The present study aimed to compare nitrous oxide-mediated increases in cuff pressure between the disposable type air-Q (air-Q-DT) and re-use type air-Q (air-Q-RU) in a simulated adult airway model. Automated cuff pressure was adjusted to 10, 20, and 30 cmH2O. The air-Q-DT and air-Q-RU were exposed to 80% nitrous oxide and cuff pressure was measured 15 and 30 minutes later. Cuff pressure of the air-Q-DT was significantly lower than that of the air-Q-RU after 15 and 30 minutes, regardless of the initial pressure. The polyvinyl chloride-based air-Q-DT may be more effective than the silicon-based air-Q-RU in preventing hyperinflation of the tracheal tube cuff in response to nitrous oxide exposure.
Stevens, Gregory J; Warfel, Joel W; Aden, James K; Blackwell, Scott D
2018-02-13
Endotracheal intubation is a medical procedure that is often indicated in both the perioperative and critical care environments. Cuffed endotracheal tubes (ETT) allow for safer and more efficient delivery of positive pressure ventilation, as well as create a barrier to reduce the risk of micro-aspiration and anesthetic pollution in the operating room environment. Over-inflation of the endotracheal cuff can lead to serious and harmful sequelae. This study aimed to assess if departmental education paired with ready access to a manometer to assess cuff pressure would result in an improvement in the proportion of ETT cuff pressures in the goal range. A quality improvement study was conducted at the San Antonio Military Medical Center (SAMMC; Department of Defense hospital in San Antonio, TX). The initiative was divided into three key periods: pre-implementation, implementation, and post-implementation. During the pre-implementation period, ETT cuff pressures were obtained to assess the baseline state of ETT cuff pressures for patients in the operating room; the proportion of in-range (20-30 cmH2O) pressures was calculated. During the implementation phase, operating rooms were equipped with manometers and anesthesia departmental education was performed regarding the use of the manometers. Three months later, post-implementation cuff pressures were measured in the OR, and the proportion of in-range pressures was again calculated. The pre-implementation data showed an average cuff pressure of 48.92 cmH2O and a median of 38.5 cmH2O. Of the 100 pre-implementation pressures, 20 were in the goal range. Post-implementation data had an average cuff pressure of 41.96 cmH2O and a median of 30 cmH2O. A chi-squared test of pressures in the safe range from the pre-implementation versus post-implementation values yielded a highly significant p-value of 0.0003. The data from this study clearly demonstrated a statistically significant improvement in the proportion of in-range cuff pressures following the quality improvement initiative. This study supports the use of department-wide education and the availability of manometers in each OR to yield safer cuff pressures for intubated patients. This study did not aim to determine an optimal ETT cuff pressure, but utilized data already available to determine a safe cuff pressure. Further research needs to be performed to assess whether routine monitoring of cuff pressure results in improved patient outcomes. Published by Oxford University Press on behalf of the Association of Military Surgeons of the United States 2018. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Efrati, Shai; Bolotin, Gil; Levi, Leon; Zaaroor, Menashe; Guralnik, Ludmila; Weksler, Natan; Levinger, Uriel; Soroksky, Arie; Denman, William T; Gurman, Gabriel M
2017-10-01
Many of the complications of mechanical ventilation are related to inappropriate endotracheal tube (ETT) cuff pressure. The aim of the current study was to evaluate the effectiveness of automatic cuff pressure closed-loop control in patients under prolonged intubation, where presence of carbon dioxide (CO2) in the subglottic space is used as an indicator for leaks. The primary outcome of the study is leakage around the cuff quantified using the area under the curve (AUC) of CO2 leakage over time. This was a multicenter, prospective, randomized controlled, noninferiority trial including intensive care unit patients. All patients were intubated with the AnapnoGuard ETT, which has an extra lumen used to monitor CO2 levels in the subglottic space.The study group was connected to the AnapnoGuard system operating with cuff control adjusted automatically based on subglottic CO2 (automatic group). The control group was connected to the AnapnoGuard system, while cuff pressure was managed manually using a manometer 3 times/d (manual group). The system recorded around cuff CO2 leakage in both groups. Seventy-two patients were recruited and 64 included in the final analysis. The mean hourly around cuff CO2 leak (mm Hg AUC/h) was 0.22 ± 0.32 in the manual group and 0.09 ± 0.04 in the automatic group (P = .01) where the lower bound of the 1-sided 95% confidence interval was 0.05, demonstrating noninferiority (>-0.033). Additionally, the 2-sided 95% confidence interval was 0.010 to 0.196, showing superiority (>0.0) as well. Significant CO2 leakage (CO2 >2 mm Hg) was 0.027 ± 0.057 (mm Hg AUC/h) in the automatic group versus 0.296 ± 0.784 (mm Hg AUC/h) in the manual group (P = .025). In addition, cuff pressures were in the predefined safety range 97.6% of the time in the automatic group compared to 48.2% in the automatic group (P < .001). This study shows that the automatic cuff pressure group is not only noninferior but also superior compared to the manual cuff pressure group. Thus, the use of automatic cuff pressure control based on subglottic measurements of CO2 levels is an effective method for ETT cuff pressure optimization. The method is safe and can be easily utilized with any intubated patient.
Validation of a Cephalad Fluid Shift Countermeasure
NASA Technical Reports Server (NTRS)
Macias, B.; Cole, C.; Kesari, S.; Hargens, A.; Stenger, M.; Ebert, D.; Lee, S. M. C.; Sargsyan, A.; Liu, J.
2016-01-01
INTRODUCTION: This project will provide critical data required to objectively determine how an optimized thigh cuff could be incorporated into the NASA integrated physiological countermeasure suite. This project will determine if thigh cuffs used during simulated spaceflight impact intracranial pressure (ICP), ocular structure and function, and intraocular pressure (IOP) using state of-the-art techniques. Additionally, some of the same methods, hardware, and protocols will be employed in the present investigation to enable direct comparisons to the International Space Station (ISS) "Fluid Shifts" experiment with Chibis-Lower Body Negative Pressure (LBNP). This study will determine the temporal physiological responses of thigh cuff application and removal on ocular and cerebral variables (including invasive ICP) in a microgravity analog. Furthermore, this proposed study will determine tissue pressure distribution applied by thigh cuffs in order to improve comfort, mobility, and efficacy of the countermeasure. Our specific aim is to determine the efficacy of a novel thigh cuff device to mitigate cephalad fluid shifts. We hypothesize that a thigh cuff countermeasure employed in a microgravity analog will temporarily reverse or attenuate ocular and cerebral-volume-pressure variables, approaching normal Earth-based seated posture, the most frequent posture assumed in daily life. In addition, we hypothesize that the magnitude of fluid and pressure redistribution using a thigh cuff countermeasure may require a longer exposure time than that of Chibis-LBNP (using ground-based data from our "Fluid Shifts" project). This project directly addresses Critical Path Roadmap Risks and Questions regarding "Risk of Spaceflight-Induced Intracranial Hypertension/Vision Alterations," and IRP Gap VIIP13: We need to identify preventative and treatment countermeasures to mitigate changes in ocular structure and function and intracranial pressure during spaceflight. METHODS: Noninvasive measures and tissue pressure distributions beneath thigh cuffs The objectives of this study are to: 1) determine the distribution of skin surface pressures beneath the advanced thigh cuff in ten subjects, 2) calibrate the built-in pressure measurement system of the advanced thigh cuff using an industry standard device, and 3) collect subjective feedback and data on the new cuff design to allow for further adjustments prior to invasive studies. A Tekscan Industrial Sensing (I-Scan) system will measure the pressure distribution of the advanced thigh cuff against the skin. In addition, we will measure blood pooling in the thigh and record the circumference of the thigh using Hokanson strain gauge plethysmography. The advanced thigh cuff will be adjusted to obtain a skin contact pressure of 30-50 mmHg as visualized on the Tekscan system. The built-in advanced thigh cuff pressure monitor will be recorded simultaneously to allow direct comparison to the Tekscan measurements. The volunteer will then remove the thigh cuff and remain at rest for five minutes with no legging applied. The thigh cuff will be donned again and pressure measurements will be taken in the same manner for up to 10 repetitions to show reproducibility of pressure after donning. At the conclusion of the study, subjects will be asked to flex their knee, stand, walk, and sit with the thigh cuff activated. During each of these maneuvers the subject will rate their pain/comfort using a modified Borg scale. Effect of thigh cuffs on ICP during simulated microgravity Ommaya reservoir patients will be recruited from the John Wayne Cancer Institute. Ommaya reservoirs provide safe and direct access for the measurement of ICP. Subjects will be instrumented for continuous blood pressure, ECG, and invasive ICP measures. The subjects will be positioned in the upright sitting posture for a 10-minute stabilization period. After the 10-minute stabilization period, imaging measures [ICP, Optical Coherence Tomography, IOP, ocular and vascular ultrasound] will be performed. Following baseline seated measures, the subject will be positioned randomly in the supine, 15deg head-down-tilt, and 15deg head-down-tilt with thigh cuffs and measures repeated. DISCUSSION: Tests to down-select thigh cuff designs will occur in early 2016. Invasive ICP and noninvasive eye imaging tests will begin in spring 2016. Supported by NSBRI through NCC 9-58.
Reyes, Bryan A; Hull, Brandon R; Kurth, Alexander B; Kukowski, Nathan R; Mulligan, Edward P; Khazzam, Michael S
2017-11-01
Many patients with rotator cuff tears suffer from nocturnal shoulder pain, resulting in sleep disturbance. To determine whether rotator cuff tear size correlated with sleep disturbance in patients with full-thickness rotator cuff tears. Cross-sectional study; Level of evidence, 3. Patients with a diagnosis of unilateral full-thickness rotator cuff tears (diagnosed via magnetic resonance imaging [MRI]) completed the Pittsburgh Sleep Quality Index (PSQI), a visual analog scale (VAS) quantifying their shoulder pain, and the American Shoulder and Elbow Surgeons (ASES) questionnaire. Shoulder MRI scans were analyzed for anterior-posterior tear size (mm), tendon retraction (mm), Goutallier grade (0-4), number of tendons involved (1-4), muscle atrophy (none, mild, moderate, or severe), and humeral head rise (present or absent). Bivariate correlations were calculated between the MRI characteristics and baseline survey results. A total of 209 patients with unilateral full-thickness rotator cuff tears were included in this study: 112 (54%) female and 97 (46%) male (mean age, 64.1 years). On average, shoulder pain had been present for 24 months. The mean PSQI score was 9.8, and the mean VAS score was 5.0. No significant correlations were found between any of the rotator cuff tear characteristics and sleep quality. Only tendon retraction had a significant correlation with pain. Although rotator cuff tears are frequently associated with nocturnal pain and sleep disruption, this study demonstrated that morphological characteristics of full-thickness rotator cuff tears, such as size and tendon retraction, do not correlate with sleep disturbance and have little to no correlation with pain levels.
Petrillo, S; Longo, U G; Papalia, R; Denaro, V
2017-08-01
To report the outcomes and complications of reverse shoulder arthroplasty (RSA) in massive irreparable rotator cuff tears (MIRCT) and cuff tear arthropathy (CTA). A systematic review of the literature contained in Medline, Cochrane, EMBASE, Google Scholar and Ovid databases was conducted on May 1, 2016, according to PRISMA guidelines. The key words "reverse total shoulder arthroplasty" or "reverse total shoulder prostheses" with "rotator cuff tears"; "failed rotator cuff surgery"; "massive rotator cuff tears"; "irreparable rotator cuff tears"; "cuff tear arthropathy"; "outcomes"; "complications" were matched. All articles reporting outcomes and complications of RSA for the management of MIRCT or CTA were included. The comparison between preoperative and postoperative clinical scores, as well as range of motion (ROM), was performed using the Wilcoxon-Mann-Whitney test. P values lower than 0.05 were considered statistically significant. Seven articles were included in our qualitative synthesis. A statistically significant improvement in all clinical scores and ROM was found comparing the preoperative value with the postoperative value. The degrees of retroversion of the humeral stem of the RSA do not influence the functional outcomes in a statistically significant fashion. There were 17.4% of complications. The most frequent was heterotopic ossification, occurring in 6.6% of patients. Revision surgery was necessary in 7.3% of patients. RSA restores pain-free ROM and improves function of the shoulder in patients with MIRCT or CTA. However, complications occur in a high percentage of patients. The lack of level I studies limits the real understanding of the potentials and limitations of RSA for the management of MIRCT and CTA.
Hollman, Freek; Wolterbeek, Nienke; Flikweert, Petra E; Yang, Kiem G Auw
2018-06-01
Fatty infiltration is an important prognostic factor for cuff healing after rotator cuff repair. Treatment options for stage 2-3 Goutallier rotator cuff tears vary widely and there is lack of decent comparative studies. The objective of this study was 1) to give an overview of the treatment options of stage 2-3 Goutallier rotator cuff tears and their clinical outcome and 2) to give a recommendation of the optimal treatment within this specific subgroup. We searched the databases of Medline, Embase, Cochrane library, NHS Centre for Reviews and Dissemination, PEDro from inception to December 12th, 2016. Two authors, F.H. and N.W., selected the studies after consensus. Data was extracted by one author (F.H.) and checked for completeness by a second author (N.W.). Our primary outcome was physical function, measured by shoulder-specific patient reported outcomes. Secondary outcomes were cuff integrity after rotator cuff repair, shoulder pain, general health, quality of life, activity level and adverse events. For the first research question 28 prospective as well as retrospective studies were included. For the clinical outcome of these treatments three randomized controlled trials were included. Despite the high reported retear rate, rotator cuff repair has comparable results (clinical improvement) as partial repair and isolated bicepstenotomy or tenodesis. These findings suggest that the additional effect of rotator cuff repair compared to the less extensive treatment options like isolated bicepstenotomy or tenodesis should be studied, as these might form a good alternative treatment based on this systematic review. Level IV; systematic review.
Bayle, Xavier; Pham, Thuy-Trang; Faruch, Marie; Gobet, Aurelie; Mansat, Pierre; Bonnevialle, Nicolas
2017-12-01
Arthroscopic techniques tend to become the gold standard in rotator cuff repair. However, little data are reported in the literature regarding the improvement of postoperative outcomes and re-tear rate relative to conventional open surgery. The aim of this study was to compare clinical outcomes and cuff integrity after arthroscopic versus open cuff repair. We prospectively assessed clinical outcomes and cuff integrity after an arthroscopic or open rotator cuff repair with a minimum follow-up of 12 months. Clinical evaluation was based on Constant score, Simple Shoulder Value (SSV) and American Shoulder and Elbow Score (ASES). Rotator cuff healing was explored with ultrasound. 44 patients in arthroscopic group A (mean age 56-year-old) and 43 in open group O (mean age 61-year-old) fulfilled the inclusion criteria. Tendons were repaired with a single row technique associated with biceps tenodesis and subacromial decompression. All objective clinical scores significantly improved postoperatively in both groups. No statistical difference was identified between group A and O regarding, respectively, Constant score (72 vs 75 points; p = 0.3), ASES score (88 vs 91 points; p = 0.3), and SSV (81 vs 85%). The overall rate of re-tear (Sugaya type IV or V) reached 7 and 9%, respectively, in group A and O (p = 0.8). This study did not prove any difference of arthroscopic over open surgery in case of rotator cuff repair regarding clinical outcome and cuff integrity at 1-year follow-up. Prospective comparative study.
The development of confocal arthroscopy as optical histology for rotator cuff tendinopathy.
Wu, J-P; Walton, M; Wang, A; Anderson, P; Wang, T; Kirk, T B; Zheng, M H
2015-09-01
MRI, ultrasound and video arthroscopy are traditional imaging technologies for noninvasive or minimal invasive assessment of the rotator cuff tendon pathology. However, these imaging modalities do not have sufficient resolution to demonstrate the pathology of rotator cuff tendons at a microstructural level. Therefore, they are insensitive to low-level tendon diseases. Although traditional histology can be used to analyze the physiology of rotator cuff tendons, it requires biopsy that traumatizes the rotator cuff, thus, potentially comprising the mechanical properties of tendons. Besides, it cannot offer real-time histological information. Confocal endoscopy offers a way to assess the microstructural disorder in tissues without biopsy. However, the application of this useful technique for detecting low-level tendon diseases has been restricted by using clinical grade fluorescent contrast agent to acquire high-resolution microstructural images of tendons. In this study, using a clinical grade sodium fluorescein contrast agent, we have reported the development of confocal arthroscopy for optical histological assessment without biopsy. The confocal arthroscopic technique was able to demonstrate rotator cuff tendinopathy in human cadavers, which appeared macroscopically normal under video arthroscopic examinations. The tendinopathy status of the rotator cuff tendons was confirmed by corresponding traditional histology. The development of confocal arthroscopy may provide a minimally invasive imaging technique for real-time histology of rotator cuff without the need for tissue biopsy. This technique has the potential for surgeons to gain in real time the histological information of rotator cuff tendons, which may assist planning repair strategies and potentially improve intervention outcomes. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
Performance of the PneuX System: A Bench Study Comparison With 4 Other Endotracheal Tube Cuffs.
Chenelle, Christopher T; Itagaki, Taiga; Fisher, Daniel F; Berra, Lorenzo; Kacmarek, Robert M
2017-01-01
Cuff design affects microaspiration, a risk factor for pneumonia. We questioned whether the PneuX low-volume fold-free cuff design would prevent cuff leakage and maintain the same tracheal wall pressure as high-volume, low-pressure (HVLP) cuffs. We evaluated 4 HVLP-cuffed endotracheal tubes (ETTs), Hi-Lo (polyvinyl chloride [PVC]), Microcuff (polyurethane [PU]), SealGuard (PU + tapered), and TaperGuard (PVC + tapered), and the PneuX with its dedicated tracheal seal monitor. In Part 1, we determined tracheal wall pressure using each cuff's capacity to support water columns across recommended intracuff pressures. In Part 2, we evaluated the tracheal seal monitor function at recommended settings. In Part 3, we compared leakage volumes of all ETTs during 30 min of simulated mechanical ventilation or during 8 h if no leak occurred. Parts 1 and 3 were performed with/without lubrication and PEEP. In Part 1, PneuX cuffs exerted an average tracheal wall pressure of 27.4 ± 2.4 cm H 2 O at the recommended intracuff pressure of approximately 80 cm H 2 O. Tracheal wall pressure did not differ among HVLP cuffs (19.6 ± 1.4 to 29.5 ± 1.4 cm H 2 O). In Part 2, preinflation intracuff pressure affected the time to obtain tracheal seal monitor pressure attainment (P < .01). The tracheal seal monitor generated average calculated tracheal wall pressure of 33.4 ± 1.2 cm H 2 O. In Part 3, PneuX ETT showed no leak across 8 h for all trials. Overall, leakage volume was lower with PU (P < .01) and PneuX (P < .01) than with PVC cuffs, regardless of shape, and lower with lubrication and/or PEEP (all P < .01). In each HVLP cuff, lubrication alone eliminated leak at an intracuff pressure of ≤30 cm H 2 O. The PneuX cuff generally exerted acceptable tracheal wall pressure, but the tracheal wall pressure monitor allowed pressures exceeding 30 cm H 2 O in some trials and was the only ETT to prevent leak in all tests. For HVLP cuffs, leak was reduced by PU and PEEP and eliminated by lubrication. Copyright © 2017 by Daedalus Enterprises.
Evaluation of the Risk Factors for a Rotator Cuff Retear After Repair Surgery.
Lee, Yeong Seok; Jeong, Jeung Yeol; Park, Chan-Deok; Kang, Seung Gyoon; Yoo, Jae Chul
2017-07-01
A retear is a significant clinical problem after rotator cuff repair. However, no study has evaluated the retear rate with regard to the extent of footprint coverage. To evaluate the preoperative and intraoperative factors for a retear after rotator cuff repair, and to confirm the relationship with the extent of footprint coverage. Cohort study; Level of evidence, 3. Data were retrospectively collected from 693 patients who underwent arthroscopic rotator cuff repair between January 2006 and December 2014. All repairs were classified into 4 types of completeness of repair according to the amount of footprint coverage at the end of surgery. All patients underwent magnetic resonance imaging (MRI) after a mean postoperative duration of 5.4 months. Preoperative demographic data, functional scores, range of motion, and global fatty degeneration on preoperative MRI and intraoperative variables including the tear size, completeness of rotator cuff repair, concomitant subscapularis repair, number of suture anchors used, repair technique (single-row or transosseous-equivalent double-row repair), and surgical duration were evaluated. Furthermore, the factors associated with failure using the single-row technique and transosseous-equivalent double-row technique were analyzed separately. The retear rate was 7.22%. Univariate analysis revealed that rotator cuff retears were affected by age; the presence of inflammatory arthritis; the completeness of rotator cuff repair; the initial tear size; the number of suture anchors; mean operative time; functional visual analog scale scores; Simple Shoulder Test findings; American Shoulder and Elbow Surgeons scores; and fatty degeneration of the supraspinatus, infraspinatus, and subscapularis. Multivariate logistic regression analysis revealed patient age, initial tear size, and fatty degeneration of the supraspinatus as independent risk factors for a rotator cuff retear. Multivariate logistic regression analysis of the single-row group revealed patient age and fatty degeneration of the supraspinatus as independent risk factors for a rotator cuff retear. Multivariate logistic regression analysis of the transosseous-equivalent double-row group revealed a frozen shoulder as an independent risk factor for a rotator cuff retear. Our results suggest that patient age, initial tear size, and fatty degeneration of the supraspinatus are independent risk factors for a rotator cuff retear, whereas the completeness of rotator cuff repair based on the extent of footprint coverage and repair technique are not.
Rotator cuff tears in children and adolescents: experience at a large pediatric hospital.
Zbojniewicz, Andrew M; Maeder, Matthew E; Emery, Kathleen H; Salisbury, Shelia R
2014-06-01
Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between rotator cuff tears and physeal patency (P > 0.05). Most patients were athletes (76%). Five tears were confirmed at surgery. Poor clinical follow-up limited evaluation of patient outcomes. Rotator cuff tears can be identified during MRI examination of symptomatic child and adolescent shoulders and often consist of tear patterns associated with repetitive microtrauma in overhead athletic activities or with single traumatic events. Rotator cuff tears are seen throughout the range of skeletal maturity, often coexist with labral tears and typically are found in athletes.
Kumar, Rakesh; Gupta, Ekta; Kumar, Sunil; Rani Sharma, Kavita; Rani Gupta, Neera
2013-03-01
Softer endotracheal (ET) tubes are more difficult to navigate in the oropharynx than the stiffer polyvinyl chloride (PVC) tubes during nasotracheal intubation (NTI). Cuff inflation has been used to guide PVC tubes into the laryngeal inlet during blind NTI, but it has not been tested when performing NTI under direct laryngoscopic guidance. We assessed the role of cuff inflation in improving oropharyngeal navigation of 3 ET tubes of varying stiffness during direct laryngoscope-guided NTI. Simultaneously, we also assessed and compared the nasotracheal navigability and incidence of nasal injury with these ET tubes during cuff inflation-supplemented, laryngoscope-guided NTI. One hundred sixty-two adults were randomized to undergo NTI with either a conventional PVC (n = 54), wire reinforced (WR; n = 54) or a silicone-tipped WR (SWR; n = 54) ET tube. Ease of insertion of these tubes was assessed during passage from nose into oropharynx, from oropharynx into laryngeal inlet aided by cuff inflation if needed, and from laryngeal inlet into trachea. Nasal morbidity was assessed by a blinded observer. All ET tubes could be inserted into the trachea. Seventy-one of 162 ET tubes could be inserted from the oropharynx into the laryngeal inlet without cuff inflation. Eighty-six of the remaining 91 tubes that did not enter the laryngeal inlet without cuff inflation could be inserted when using the cuff inflation technique. Thus, a total of 157 ET tubes could be inserted into the laryngeal inlet with cuff inflation (95% confidence interval of difference of proportions between total number of tubes passed [157] and those without cuff inflation [71]: 53% [45%-61%]). The remaining 5 tubes had to be inserted with the help of Magill forceps. The incidence of epistaxis was lowest with the SWR tube (difference of proportions [95% confidence interval] SWR versus PVC 27% [8%-45%]; SWR versus WR 20% [1%-38%]; WR versus PVC 7% [-12% to 26%]). The cuff inflation technique consistently improved the oropharyngeal insertion of the 3 ET tubes of varying stiffness during direct laryngoscope-guided NTI. Supplemented with the cuff inflation technique, the SWR ET tube seems to be better than the PVC and WR ET tubes in terms of complete nasotracheal navigability and less perioperative nasal injury.
Rotator cuff tear measurement by arthropneumotomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kilcoyne, R.F.; Matsen, F.A. III
1983-02-01
Five years of experience with a method of shoulder arthrography using upright tomography in cases of suspected or known rotator cuff tears has demonstrated its effectiveness. The value of the procedure lies in its ability to demonstrate the size of the cuff tear and the thickness of the remaining cuff tissue. This information provides the surgeon with a preoperative estimate of the difficulty of the repair and the prognosis for a good functional recovery. In 33 cases, there was good correlation between the upright thin-section tomogram findings and the surgical results. The tomograms provided better information about the size ofmore » the tear and the quality of the remaining cuff than did plain arthrograms.« less
Multipolar modes in dielectric disk resonator for wireless power transfer
NASA Astrophysics Data System (ADS)
Song, Mingzhao; Belov, Pavel; Kapitanova, Polina
2017-09-01
We demonstrate a magnetic resonant WPT system based on dielectric disk resonators and investigated the WPT efficiency as a function of separation. It has been demonstrated that the power transfer can be achieved at different multipolar modes. The numerical study shows that the highest WPT efficiency of 99% can be obtained for the MQ mode in an ideal case. However, the efficiency of MQ mode decays much faster than the MD mode which suggests that a trade-off has to be made in the practical WPT system design.
NASA Technical Reports Server (NTRS)
Yu, Anthony W.; Harding, David J.; Dabney, Philip W.
2016-01-01
The Slope Imaging Multi-polarization Photon-counting Lidar (SIMPL) instrument is a polarimetric, two-color, multibeam push broom laser altimeter developed through the NASA Earth Science Technology Office Instrument Incubator Program and has been flown successfully on multiple airborne platforms since 2008. In this talk we will discuss the laser transmitter performance and present recent science data collected over the Greenland ice sheet and sea ice in support of the NASA Ice Cloud and land Elevation Satellite 2 (ICESat-2) mission to be launched in 2017.
Muzlovic, Igor; Perme, Janja; Stubljar, David
2018-05-01
The aim of the study was to investigate whether polyurethane (PU) endotracheal tubes, continuous measurements of cuff pressure and aspiration of the subglottic space as a bundle of parameters could reduce patients' risk for developing ventilator associated pneumonia (VAP). Two groups of patients that differed only in terms of endotracheal tubes and intubation intervention were compared. Group A was ventilated using PU tubes a with conical cuff; they also had continuous cuff pressure measurement and continuous subglottic aspiration. Group B was ventilated using PVC tubes with a cylindrical cuff; the patients underwent intermittent cuff pressure measurement and intermittent subglottic aspiration. Seven patients in group A (13.2%) and 18 in group B (36.0%) out of 103 were diagnosed with VAP. VAP patients were in general older, stayed longer in the ICU and were ventilated significantly longer compared with the patients with no VAP. Eight more patients in group B died compared with group A. Moreover, subjects in group A survived longer. Patient age, hours on mechanical ventilation, and days on an ICU were all positively associated with the occurrence of VAP. Prevention parameters in ventilation (PU cuff, conical cuff, continuous subglottic drainage and continuous cuff pressure measurement) could prevent the incidence of VAP in ICU patients.
Namdari, Surena; Baldwin, Keith; Ahn, Albert; Huffman, G Russell; Sennett, Brian J
2011-01-01
Little is known about pitching performance or lack of it among Major League Baseball (MLB) pitchers who undergo operative treatment of rotator cuff tears. To assess pitching performance outcomes in MLB players who needed operative treatment of rotator cuff tears and to compare performance in these athletes with that in a control group of MLB players. Case-control study. Publicly available player profiles, press releases, and team injury reports. Thirty-three MLB pitchers with documented surgery to treat rotator cuff tears and 117 control pitchers who did not have documented rotator cuff tears were identified. Major League Baseball pitching attrition and performance variables. Players who underwent rotator cuff surgery were no more likely not to play than control players. Performance variables of players who underwent surgery improved after surgery but never returned to baseline preoperative status. Players who needed rotator cuff surgery typically were more experienced and had better earned run averages than control players. Pitchers who had symptomatic rotator cuff tears that necessitated operative treatment tended to decline gradually in performance leading up to their operations and to improve gradually over the next 3 seasons. In contrast to what we expected, they did not have a greater attrition rate than their control counterparts; however, their performances did not return to preoperative levels over the course of the study.
Fonseca-Reyes, Salvador; Fajardo-Flores, Ismael; Montes-Casillas, Mayra; Forsyth-Macquarrie, Avril
2009-08-01
This study analyzed systolic and diastolic blood pressure (SBP and DBP) reading differences in individuals with muscular arms, using medium and large adult cuffs. Resting blood pressures (BPs) were measured in bodybuilders competing at the Mexican National Bodybuilding and Fitness Championship. The means of two bilateral simultaneous arm BP measurements were obtained using two different cuff sizes, 12 cm (medium adult) and 16 cm (large adult). A total of 193 bodybuilders completed the measurements. With an arm circumference greater than 33 cm, the SBP and DBP average taken with the medium adult cuff was higher than that obtained with the large adult cuff, 8.2+/-10.6 and 1.6+/-7.4 mmHg, respectively; however, a significant difference was observed only with the SBP. With the medium adult cuff, 48 of 144 individuals showed SBP at least 140 mmHg, whereas with the large adult cuff there were only 17 of 144 individuals. In those participants with an arm circumference less than 33 cm, the BP was nonsignificantly lower with the large cuff, -4.24+/-9.2 and -2.24+/-5.4 mmHg for the SBP and DBP, respectively. Incorrect cuffing of a muscular arm leads to significant errors in the measurement of SBP and DBP, similar to that observed in miscuffing of nonmuscular arms.
The Societal and Economic Value of Rotator Cuff Repair
Mather, Richard C.; Koenig, Lane; Acevedo, Daniel; Dall, Timothy M.; Gallo, Paul; Romeo, Anthony; Tongue, John; Williams, Gerald
2013-01-01
Background: Although rotator cuff disease is a common musculoskeletal problem in the United States, the impact of this condition on earnings, missed workdays, and disability payments is largely unknown. This study examines the value of surgical treatment for full-thickness rotator cuff tears from a societal perspective. Methods: A Markov decision model was constructed to estimate lifetime direct and indirect costs associated with surgical and continued nonoperative treatment for symptomatic full-thickness rotator cuff tears. All patients were assumed to have been unresponsive to one six-week trial of nonoperative treatment prior to entering the model. Model assumptions were obtained from the literature and data analysis. We obtained estimates of indirect costs using national survey data and patient-reported outcomes. Four indirect costs were modeled: probability of employment, household income, missed workdays, and disability payments. Direct cost estimates were based on average Medicare reimbursements with adjustments to an all-payer population. Effectiveness was expressed in quality-adjusted life years (QALYs). Results: The age-weighted mean total societal savings from rotator cuff repair compared with nonoperative treatment was $13,771 over a patient’s lifetime. Savings ranged from $77,662 for patients who are thirty to thirty-nine years old to a net cost to society of $11,997 for those who are seventy to seventy-nine years old. In addition, surgical treatment results in an average improvement of 0.62 QALY. Societal savings were highly sensitive to age, with savings being positive at the age of sixty-one years and younger. The estimated lifetime societal savings of the approximately 250,000 rotator cuff repairs performed in the U.S. each year was $3.44 billion. Conclusions: Rotator cuff repair for full-thickness tears produces net societal cost savings for patients under the age of sixty-one years and greater QALYs for all patients. Rotator cuff repair is cost-effective for all populations. The results of this study should not be interpreted as suggesting that all rotator cuff tears require surgery. Rather, the results show that rotator cuff repair has an important role in minimizing the societal burden of rotator cuff disease. PMID:24257656
Knobloch, Karsten; Grasemann, Ruth; Spies, Marcus; Vogt, Peter M
2008-11-01
The effect of combined cryotherapy/compression versus cryotherapy alone on the Achilles tendon is undetermined. Standardized combined cryotherapy/compression changes in midportion Achilles tendon microcirculation are superior to those with cryotherapy during intermittent application. Controlled laboratory study. Sixty volunteers were randomized for either combined cryotherapy/compression (Cryo/Cuff, DJO Inc, Vista, California: n = 30; 32 +/- 11 years) or cryotherapy alone (KoldBlue, TLP Industries, Kent, United Kingdom: n = 30; 33 +/- 12 years) with intermittent 3 x 10-minute application. Midportion Achilles tendon microcirculation was determined (O2C, LEA Medizintechnik, Giessen, Germany). Both Cryo/Cuff and KoldBlue significantly reduced superficial and deep capillary tendon blood flow within the first minute of application (43 +/- 46 arbitrary units [AU] vs 10 +/- 19 AU and 42 +/- 46 AU vs 12 +/- 10 AU; P = .0001) without a significant difference throughout all 3 applications. However, during recovery, superficial and deep capillary blood flow was reestablished significantly faster using Cryo/Cuff (P = .023). Tendon oxygen saturation was reduced in both groups significantly (3 minutes Cryo/Cuff: 36% +/- 20% vs 16% +/- 15%; KoldBlue: 42% +/- 19% vs 28% +/- 20%; P < .05) with significantly stronger effects using Cryo/Cuff (P = .014). Cryo/Cuff led to significantly higher tendon oxygenation (Cryo/Cuff: 62% +/- 28% vs baseline 36% +/- 20%; P = .0001) in superficial and deep tissue (Cryo/Cuff: 73% +/- 14% vs baseline 65% +/- 17%; P = .0001) compared with KoldBlue during all recoveries. Postcapillary venous filling pressures were significantly reduced in both groups during application; however, Cryo/Cuff led to significantly, but marginally, lower pressures (Cryo/Cuff: 41 +/- 7 AU vs baseline 51 +/- 13 AU; P = .0001 and KoldBlue: 46 +/- 7 AU vs baseline 56 +/- 11 AU; P = .026 for Cryo/Cuff vs KoldBlue). Increased tendon oxygenation is achieved as tendon preconditioning by combined cryotherapy and compression with significantly increased tendon oxygen saturation during recovery in contrast to cryotherapy alone. Both regimens lead to a significant amelioration of tendinous venous outflow. Combined cryotherapy and compression is superior to cryotherapy alone regarding the Achilles tendon microcirculation. Further studies in tendinopathy and tendon rehabilitation are warranted to elucidate its value regarding functional issues.
Rotator Cuff Damage: Reexamining the Causes and Treatments.
ERIC Educational Resources Information Center
Nash, Heyward L.
1988-01-01
Sports medicine specialists are beginning to reexamine the causes and treatments of rotator cuff problems, questioning the role of primary impingement in a deficient or torn cuff and trying new surgical procedures as alternatives to the traditional open acromioplasty. (Author/CB)
Pepke, W; Brunner, M; Abel, R; Almansour, H; Gerner, H J; Hug, A; Zeifang, F; Kentar, Y; Bruckner, T; Akbar, M
2018-02-27
Shoulder pain and rotator cuff tears are highly prevalent among wheelchair dependent individuals with paraplegia. The purpose of this study was to identify potential risk factors associated with the development of rotator cuff tears in this population. A total of 217 wheelchair dependent individuals with paraplegia were included in this cross-sectional study (level of evidence III). The mean age of this population was 47.9 years and the mean duration of wheelchair dependence was 24.1 years. Each individual was asked to complete a questionnaire designed to identify risk factors for rotator cuff tears and underwent a standardized clinical examination with the documentation of the Constant-Murley shoulder outcome score and magnetic resonance imaging (MRI) of both shoulder joints. MRI analysis revealed at least one rotator cuff tear in 93 patients (43%). Multiple logistic regression analysis identified the following factors to be associated with the presence of rotator cuff tear: patient age, duration of spinal cord injury/wheelchair dependence, gender, and wheelchair athletic activity. Neither BMI nor the level of spinal cord injury was found to pose a risk factor in the population studied. With respect to patient age, the risk of developing a rotator cuff tear increased by 11% per annum. In terms of duration of spinal cord injury, the analysis revealed a 6% increased risk per year of wheelchair dependence (OR = 1.06). Females had a 2.6-fold higher risk of developing rotator cuff tears than males and wheelchair sport activity increased the risk 2.3-fold. There is a high prevalence of rotator cuff tears in wheel-chair dependent persons with paraplegia. Risk factors such as age, gender, duration of paraplegia, and wheel chair sport activity seem to play an important role in the development of rotator cuff tears.
Zehnder, Ashley M; Hawkins, Michelle G; Pascoe, Peter J; Kass, Philip H
2009-09-01
To compare Doppler and oscillometric methods of indirect arterial blood pressure (IBP) with direct arterial measurements in anesthetized and awake red-tailed hawks. Prospective, randomized, blinded study. Six, sex unknown, adult red-tailed hawks. Birds were anesthetized and IBP measurements were obtained by oscillometry (IBP-O) and Doppler (IBP-D) on the pectoral and pelvic limbs using three cuffs of different width based on limb circumference: cuff 1 (20-30% of circumference), cuff 2 (30-40%), and cuff 3 (40-50%). Direct arterial pressure measurements were obtained from the contralateral superficial ulnar artery. Indirect blood pressure measurements were compared to direct systolic arterial pressure (SAP) and mean arterial pressure (MAP) during normotension and induced states of hypotension and hypertension. Measurements were also obtained in awake, restrained birds. Three-way anova, linear regression and Bland-Altman analyses were used to evaluate the IBP-D data. Results are reported as mean bias (95% confidence intervals). The IBP-O monitor reported errors during 54% of the measurements. Indirect blood pressure Doppler measurements were most accurate with cuff 3 and were comparable to MAP with a bias of 2 (-9, 13 mmHg). However, this cuff consistently underestimated SAP with a bias of 33 (19, 48 mmHg). Variability in the readings within and among birds was high. There was no significant difference between sites of cuff placement. Awake birds had SAP, MAP and diastolic arterial pressure that were 56, 43, and 38 mmHg higher than anesthetized birds. Indirect blood pressure (oscillometric) measurements were unreliable in red-tailed hawks. Indirect blood pressure (Doppler) measurements were closer to MAP measurements than SAP measurements. There was slightly better agreement with the use of cuff 3 on either the pectoral or pelvic limbs. Awake, restrained birds have significantly higher arterial pressures than those under sevoflurane anesthesia.
Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf
2017-12-01
The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally, the combination of MR imaging and clinical tests does not improve diagnostic accuracy. Level II, Diagnostic study.
Tashjian, Robert Z; Granger, Erin K; Farnham, James M; Cannon-Albright, Lisa A; Teerlink, Craig C
2016-02-01
The precise etiology of rotator cuff disease is unknown, but prior evidence suggests a role for genetic factors. Limited data exist identifying specific genes associated with rotator cuff tearing. The purpose of this study was to identify specific genes or genetic variants associated with rotator cuff tearing by a genome-wide association study with an independent set of rotator cuff tear cases. A set of 311 full-thickness rotator cuff tear cases genotyped on the Illumina 5M single-nucleotide polymorphism (SNP) platform were used in a genome-wide association study with 2641 genetically matched white population controls available from the Illumina iControls database. Tests of association were performed with GEMMA software at 257,558 SNPs that compose the intersection of Illumina SNP platforms and that passed general quality control metrics. SNPs were considered significant if P < 1.94 × 10(-7) (Bonferroni correction: 0.05/257,558). Tests of association revealed 2 significantly associated SNPs, one occurring in SAP30BP (rs820218; P = 3.8E-9) on chromosome 17q25 and another occurring in SASH1 (rs12527089; P = 1.9E-7) on chromosome 6q24. This study represents the first attempt to identify genetic factors influencing rotator cuff tearing by a genome-wide association study using a dense/complete set of SNPs. Two SNPs were significantly associated with rotator cuff tearing, residing in SAP30BP on chromosome 17 and SASH1 on chromosome 6. Both genes are associated with the cellular process of apoptosis. Identification of potential genes or genetic variants associated with rotator cuff tearing may help in identifying individuals at risk for the development of rotator cuff tearing. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Preoperative and post-operative sleep quality evaluation in rotator cuff tear patients.
Serbest, Sancar; Tiftikçi, Uğur; Askın, Aydogan; Yaman, Ferda; Alpua, Murat
2017-07-01
The aim of this study was to examine the potential relationship between subjective sleep quality and degree of pain in patients with rotator cuff repair. Thirty-one patients who underwent rotator cuff repair prospectively completed the Pittsburgh Sleep Quality Index, the Western Ontario Rotator Cuff Index, and the Constant and Murley shoulder scores before surgery and at 6 months after surgery. Preoperative demographic, clinical, and radiologic parameters were also evaluated. The study analysed 31 patients with a median age of 61 years. There was a significant difference preoperatively versus post-operatively in terms of all PSQI global scores and subdivisions (p < 0.001). A statistically significant improvement was determined by the Western Ontario Rotator Cuff Scale and the Constant and Murley shoulder scores (p ˂ 0.001). Sleep disorders are commonly seen in patients with rotator cuff tear, and after repair, there is an increase in the quality of sleep with a parallel improvement in shoulder functions. However, no statistically significant correlation was determined between arthroscopic procedures and the size of the tear and sleep quality. It is suggested that rotator cuff tear repair improves the quality of sleep and the quality of life. IV.
Tail-Cuff Technique and Its Influence on Central Blood Pressure in the Mouse.
Wilde, Elena; Aubdool, Aisah A; Thakore, Pratish; Baldissera, Lineu; Alawi, Khadija M; Keeble, Julie; Nandi, Manasi; Brain, Susan D
2017-06-27
Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of the results. C57Bl/6J mice were implanted with radio-telemetry probes to investigate the effects of the steps of the tail-cuff technique on central blood pressure, heart rate, and temperature. This included comparison of handling techniques, operator's sex, habituation, and influence of hypertension induced by angiotensin II. Direct comparison of measurements obtained by telemetry and tail-cuff were made in the same mouse. The results revealed significant increases in central blood pressure, heart rate, and core body temperature from baseline following handling interventions without significant difference among the different handling technique, habituation, or sex of the investigator. Restraint induced the largest and sustained increase in cardiovascular parameters and temperature. The tail-cuff readings significantly underestimated those from simultaneous telemetry recordings; however, "nonsimultaneous" telemetry, obtained in undisturbed mice, were similar to tail-cuff readings obtained in undisturbed mice on the same day. This study reveals that the tail-cuff technique underestimates the core blood pressure changes that occur simultaneously during the restraint and measurement phases. However, the measurements between the 2 techniques are similar when tail-cuff readings are compared with telemetry readings in the nondisturbed mice. The differences between the simultaneous recordings by the 2 techniques should be recognized by researchers. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Shah, Shivam A; Kormpakis, Ioannis; Cavinatto, Leonardo; Killian, Megan L; Thomopoulos, Stavros; Galatz, Leesa M
2017-12-01
Large rotator cuff tear size and advanced muscle degeneration can affect reparability of tears and compromise tendon healing. Clinicians often rely on direct measures of rotator cuff tear size and muscle degeneration from magnetic resonance imaging (MRI) to determine whether the rotator cuff tear is repairable. The objective of this study was to identify the relationship between gene expression changes in rotator cuff muscle degeneration to standard data available to clinicians. Radiographic assessment of preoperative rotator cuff tear severity was completed for 25 patients with varying magnitudes of rotator cuff tears. Tear width and retraction were measured using MRI, and Goutallier grade, tangent (tan) sign, and Thomazeau grade were determined. Expression of myogenic-, adipogenic-, atrophy-, and metabolism-related genes in biopsied muscles were correlated with tear width, tear retraction, Goutallier grade, tan sign, and Thomazeau grade. Tear width positively correlated with Goutallier grade in both the supraspinatus (r = 0.73) and infraspinatus (r = 0.77), along with tan sign (r = 0.71) and Thomazeau grade (r = 0.68). Decreased myogenesis (Myf5), increased adipogenesis (CEBPα, Lep, Wnt10b), and decreased metabolism (PPARα) correlated with radiographic assessments. Gene expression changes suggest that rotator cuff tears lead to a dramatic molecular response in an attempt to maintain normal muscle tissue, increase adipogenesis, and decrease metabolism. Fat accumulation and muscle atrophy appear to stem from endogenous changes rather than from changes mediated by infiltrating cells. Results suggest that chronic unloading of muscle, induced by rotator cuff tear, disrupts muscle homeostasis. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2808-2814, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Augmentation of Rotator Cuff Repair With Soft Tissue Scaffolds
Thangarajah, Tanujan; Pendegrass, Catherine J.; Shahbazi, Shirin; Lambert, Simon; Alexander, Susan; Blunn, Gordon W.
2015-01-01
Background Tears of the rotator cuff are one of the most common tendon disorders. Treatment often includes surgical repair, but the rate of failure to gain or maintain healing has been reported to be as high as 94%. This has been substantially attributed to the inadequate capacity of tendon to heal once damaged, particularly to bone at the enthesis. A number of strategies have been developed to improve tendon-bone healing, tendon-tendon healing, and tendon regeneration. Scaffolds have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects but may not possess situation-specific or durable mechanical and biological characteristics. Purpose To provide an overview of the biology of tendon-bone healing and the current scaffolds used to augment rotator cuff repairs. Study Design Systematic review; Level of evidence, 4. Methods A preliminary literature search of MEDLINE and Embase databases was performed using the terms rotator cuff scaffolds, rotator cuff augmentation, allografts for rotator cuff repair, xenografts for rotator cuff repair, and synthetic grafts for rotator cuff repair. Results The search identified 438 unique articles. Of these, 214 articles were irrelevant to the topic and were therefore excluded. This left a total of 224 studies that were suitable for analysis. Conclusion A number of novel biomaterials have been developed into biologically and mechanically favorable scaffolds. Few clinical trials have examined their effect on tendon-bone healing in well-designed, long-term follow-up studies with appropriate control groups. While there is still considerable work to be done before scaffolds are introduced into routine clinical practice, there does appear to be a clear indication for their use as an interpositional graft for large and massive retracted rotator cuff tears and when repairing a poor-quality degenerative tendon. PMID:26665095
Does arthroscopic rotator cuff repair improve patients' activity levels?
Baumgarten, Keith M; Chang, Peter S; Dannenbring, Tasha M; Foley, Elaine K
2018-06-04
Rotator cuff repair decreases pain, improves range of motion, and increases strength. Whether these improvements translate to an improvement in a patient's activity level postoperatively remains unknown. The Shoulder Activity Level is a valid and reliable outcomes survey that can be used to measure a patient's shoulder-specific activity level. Currently, there are no studies that examine the effect of rotator cuff repair on shoulder activity level. Preoperative patient-determined outcomes scores collected prospectively on patients undergoing rotator cuff repair were compared with postoperative scores at a minimum of 2 years. These scores included the Shoulder Activity Level, Western Ontario Rotator Cuff Index, American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, Single Assessment Numeric Evaluation, and simple shoulder test. Inclusion criteria were patients undergoing arthroscopic rotator cuff repair. Included were 281 shoulders from 273 patients with a mean follow-up of 3.7 years. The postoperative median Western Ontario Rotator Cuff Index (42 vs. 94), American Shoulder and Elbow Surgeons (41 vs. 95), Single Assessment Numeric Evaluation (30 vs. 95), and simple shoulder test (4 vs. 11) scores were statistically significantly improved compared with preoperative scores (P < .0001). The postoperative median Shoulder Activity Level score decreased compared with the preoperative score (12 vs. 11; P < .0001). Patients reported a statistically significant deterioration of their Shoulder Activity Level score after rotator cuff repair compared with their preoperative scores, although disease-specific and joint-specific quality of life scores all had statistically significantly improvement. This study suggests that patients generally have (1) significant improvements in their quality of life and (2) small deteriorations in activity level after arthroscopic rotator cuff repair. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Sonoda, Yuma; Nishioka, Takashi; Nakajima, Ryo; Imai, Shinji; Vigers, Piers; Kawasaki, Taku
2018-04-01
Fall prevention is essential in patients after arthroscopic rotator cuff repair because of the high risk of re-rupture. However, there are no reports related to falls that occur during the early postoperative period, while the affected limb is immobilized. This study assessed gait performance and falls in patients using a shoulder abduction brace after arthroscopic rotator cuff repair. Prospective cohort and postoperative repeated measures. This study included 29 patients (mean age, 67.1 ± 7.4 years) who underwent arthroscopic rotator cuff repair followed by rehabilitation. The timed up and go test, Geriatric Depression Scale, and Falls Efficacy Scale were measured, and the numbers of falls were compared between those shoulder abduction brace users and patients who had undergone total hip or knee arthroplasty. In arthroscopic rotator cuff repair patients, there were significant improvements in timed up and go test and Geriatric Depression Scale, but no significant differences in Falls Efficacy Scale, between the second and fifth postoperative weeks ( p < 0.05). Additionally, arthroscopic rotator cuff repair patients fell more often than patients with total hip arthroplasty or total knee arthroplasty during the same period. The findings suggest that rehabilitation in arthroscopic rotator cuff repair patients is beneficial, but decreased gait performance due to the immobilizing shoulder abduction brace can lead to falls. Clinical relevance Although rehabilitation helps motor function and mental health after arthroscopic rotator cuff repair, shoulder abduction brace use is associated with impaired gait performance, high Falls Efficacy Scale scores, and risk of falls, so awareness of risk factors including medications and lower limb dysfunctions is especially important after arthroscopic rotator cuff repair.
Van der Bracht, Hans; Van den Langenbergh, Tom; Pouillon, Marc; Verhasselt, Skrallan; Verniers, Philippe; Stoffelen, Danny
2018-05-22
This study investigated the feasibility and safety of all-suture anchors in arthroscopic rotator cuff repair. All patients were diagnosed with a rotator cuff tear by ultrasound or magnetic resonance imaging (MRI). Patients with partial tears, massive tears, subscapularis tears, or previous shoulder surgery, were excluded. MRI and clinical outcome were investigated in all patients at 1.58 years (range, 1.0-2.0 years) after rotator cuff repair with all-suture anchors (prospective case series). Integrity of the cuff repair, cyst formation (encapsulated fluid signal around the anchor), ingrowth of the bone into the anchor, and integrity of the bone tunnel border were evaluated for 47 anchors. Clinical results were evaluated using the Constant-Murley score. An MRI evaluation was performed in 20 patients at 1.58 years (range, 1.0-2.0 years) after rotator cuff repair with all-suture anchors. MRI evaluation showed a very small rim of fluid around 10% of the anchors. None of the anchors showed cyst formation with fluid diameter more than twice the anchor diameter. In approximately 90% of the anchors, no fluid could be detected between the anchors and the edge of the bony tunnel. Full rotator cuff integrity was seen in 19 patients. Only 1 patient sustained a retear. Clinical results comparable with an arthroscopic rotator cuff repair using classic anchors were seen. This prospective clinical cohort study shows promising early radiographic and clinical results after arthroscopic rotator cuff repair using all-suture anchors. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Cadogan, Angela; McNair, Peter; Laslett, Mark; Hing, Wayne; Taylor, Stephen
2013-01-01
Objectives: Rotator cuff tears are a common and disabling complaint. The early diagnosis of medium and large size rotator cuff tears can enhance the prognosis of the patient. The aim of this study was to identify clinical features with the strongest ability to accurately predict the presence of a medium, large or multitendon (MLM) rotator cuff tear in a primary care cohort. Methods: Participants were consecutively recruited from primary health care practices (n = 203). All participants underwent a standardized history and physical examination, followed by a standardized X-ray series and diagnostic ultrasound scan. Clinical features associated with the presence of a MLM rotator cuff tear were identified (P<0.200), a logistic multiple regression model was derived for identifying a MLM rotator cuff tear and thereafter diagnostic accuracy was calculated. Results: A MLM rotator cuff tear was identified in 24 participants (11.8%). Constant pain and a painful arc in abduction were the strongest predictors of a MLM tear (adjusted odds ratio 3.04 and 13.97 respectively). Combinations of ten history and physical examination variables demonstrated highest levels of sensitivity when five or fewer were positive [100%, 95% confidence interval (CI): 0.86–1.00; negative likelihood ratio: 0.00, 95% CI: 0.00–0.28], and highest specificity when eight or more were positive (0.91, 95% CI: 0.86–0.95; positive likelihood ratio 4.66, 95% CI: 2.34–8.74). Discussion: Combinations of patient history and physical examination findings were able to accurately detect the presence of a MLM rotator cuff tear. These findings may aid the primary care clinician in more efficient and accurate identification of rotator cuff tears that may require further investigation or orthopedic consultation. PMID:24421626
Austin, Luke; Pepe, Matthew; Tucker, Bradford; Ong, Alvin; Nugent, Robert; Eck, Brandon; Tjoumakaris, Fotios
2015-06-01
Sleep disturbance is a common complaint of patients with a rotator cuff tear. Inadequate and restless sleep, along with pain, is often a driving symptom for patients to proceed with rotator cuff repair. To date, no studies have examined sleep disturbance in patients undergoing rotator cuff repair, and there is no evidence that surgery improves sleep disturbance. Sleep disturbance is prevalent in patients with a symptomatic rotator cuff tear, and sleep disturbance improves after arthroscopic rotator cuff repair. Case series; Level of evidence, 4. A total of 56 patients undergoing arthroscopic rotator cuff repair for full-thickness tears were enrolled in a prospective study. Patients were surveyed preoperatively and postoperatively at intervals of 2, 6, 12, 18, and 24 weeks. Patient outcomes were scored using the Pittsburgh Sleep Quality Index (PSQI), Simple Shoulder Test (SST), visual analog scale for pain (VAS), and single assessment numeric evaluation (SANE). Demographic and surgical factors were also collected for analysis. Preoperative PSQI scores indicative of sleep disturbance were reported in 89% of patients. After surgery, a statistically significant improvement in PSQI was achieved at 3 months (P = .0012; 91% follow-up) and continued through 6 months (P = .0179; 93% follow-up). Six months after surgery, only 38% of patients continued to have sleep disturbance. Multivariable linear regression of all surgical and demographic factors versus PSQI was performed and demonstrated that preoperative and prolonged postoperative narcotic use negatively affected sleep. Sleep disturbance is common in patients undergoing rotator cuff repair. After surgery, sleep disturbance improves to levels comparable with those of the general public. Preoperative and prolonged postoperative use of narcotic pain medication negatively affects sleep. © 2015 The Author(s).
Identification of a genetic variant associated with rotator cuff repair healing.
Tashjian, Robert Z; Granger, Erin K; Zhang, Yue; Teerlink, Craig C; Cannon-Albright, Lisa A
2016-06-01
A familial and genetic predisposition for the development of rotator cuff tearing has been identified. The purpose of this study was to determine if a familial predisposition exists for healing after rotator cuff repair and if the reported significant association with a single-nucleotide polymorphism (SNP) in the ESRRB gene is present in patients who fail to heal. The study recruited 72 patients undergoing arthroscopic rotator cuff repair for a full-thickness posterosuperior tear. Magnetic resonance imaging studies were performed at a minimum of 1 year postoperatively (average, 2.6 years). Healing failures were classified as lateral or medial. Self-reported family history of rotator cuff tearing data and genome-wide genotypes were available. Characteristics of cases with and without a family history of rotator cuff tearing were compared, and a comparison of the frequency of SNP 1758384 (in ESRRB) was performed between patients who healed and those who failed to heal. Of the rotator cuff repairs, 42% failed to heal; 42% of patients reported a family history of rotator cuff tear. Multivariate regression analysis showed a significant association between familiality and overall healing failure (medial and lateral failures) (P = .036) and lateral failures independently (P = .006). An increased risk for the presence of a rare allele for SNP rs17583842 was present in lateral failures compared with those that healed (P = .005). Individuals with a family history of rotator cuff tearing were more likely to have repair failures. Significant association of a SNP variant in the ESRRB gene was also observed with lateral failure. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Castricini, Roberto; De Benedetto, Massimo; Familiari, Filippo; De Gori, Marco; De Nardo, Pasquale; Orlando, Nicola; Gasparini, Giorgio; Galasso, Olimpio
2016-04-01
Arthroscopic-assisted latissimus dorsi tendon transfer (LDTT) has been recently introduced for treatment of irreparable, posterosuperior massive rotator cuff tears. We sought to evaluate the functional outcomes of this technique and to check for possible outcome predictors. The study reviewed 86 patients (aged 59.8 ± 5.9 years) who underwent an arthroscopic-assisted latissimus dorsi tendon transfer after 36.4 ± 9 months of follow-up. Of these, 14 patients (16.3%) sustained an irreparable massive rotator cuff tear after a failed arthroscopic rotator cuff repair. The Constant and Murley score (CMS) was used to assess patients' functionality preoperatively and at follow-up. As a group, the CMS improved with surgery from 35.5 ± 6.1 to 69.5 ± 12.3 (P < .001). A lower preoperative CMS and a previous failed rotator cuff repair resulted in lower postoperative range of motion (P = .044 and P = .007, respectively) and CMS (P = .042 and P = .018, respectively). A previous rotator cuff repair resulted in lower satisfaction with surgery (P = .009). Gender and age did not affect the clinical outcomes. Our results support the effectiveness of arthroscopic-assisted LDTT in the treatment of patients with an irreparable, posterosuperior massive rotator cuff tears in pain relief, functional recovery, and postoperative satisfaction. Patients with lower preoperative CMS and a history of failed rotator cuff repair have a greater likelihood of having a lower clinical result. However, the favorable values of summary postoperative scores do not exclude these patients as candidates for arthroscopic-assisted LDTT. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Extracorporeal shock wave therapy is not useful after arthroscopic rotator cuff repair.
Kim, Jae Yoon; Lee, Jae Sung; Park, Chi Woo
2012-12-01
Extracorporeal shock wave therapy (ESWT) is known to accelerate the healing of musculoskeletal tissue. The purpose of this study was to test the hypothesis that ESWT stimulates rotator cuff healing after arthroscopic repair. Seventy-one consecutive patients with a small- to large-sized rotator cuff tear underwent arthroscopic rotator cuff repair. The patients were randomized into two groups: 35 patients underwent ESWT at 6 weeks after surgery (ESWT group) and 36 patients did not (control group). Cuff integrity was evaluated with computed tomographic arthrography at 6 months after surgery. Constant and UCLA scores were measurable outcomes. All patients were available for a minimum one-year follow-up. The mean age of the ESWT and control groups was 59.4 (SD: 7.7) and 58.6 years (SD: 7.8) (n.s.). There were no significant differences in tear size and repair method between the two groups (n.s.). The mean Constant and UCLA scores, respectively, increased from 54.6 to 90.6 (P < 0.001) and from 18.5 to 27.4 (P < 0.001) in the ESWT group, and from 58.9 to 89.3 (P < 0.001) and 18.5 to 27.4 in the control group. Computed tomographic arthrography was performed in 26 patients from the ESWT group and 24 from the control group, and cuff integrity was maintained in 46 out of 50 patients. Definite re-tear was observed in two patients of the ESWT group and four of the controls. There were no complications associated with ESWT. This study failed to prove that ESWT stimulates rotator cuff healing after arthroscopic rotator cuff repair. Additional ESWT after rotator cuff repair could theoretically be advantageous, and it was proven to be safe in this study. II.
Magnetic Doppler imaging of 53 Camelopardalis in all four Stokes parameters
NASA Astrophysics Data System (ADS)
Kochukhov, O.; Bagnulo, S.; Wade, G. A.; Sangalli, L.; Piskunov, N.; Landstreet, J. D.; Petit, P.; Sigut, T. A. A.
2004-02-01
We present the first investigation of the structure of the stellar surface magnetic field using line profiles in all four Stokes parameters. We extract the information about the magnetic field geometry and abundance distributions of the chemically peculiar star 53 Cam by modelling time-series of high-resolution spectropolarimetric observations with the help of a new magnetic Doppler imaging code. This combination of the unique four Stokes parameter data and state-of-the-art magnetic imaging technique makes it possible to infer the stellar magnetic field topology directly from the rotational variability of the Stokes spectra. In the magnetic imaging of 53 Cam we discard the traditional multipolar assumptions about the structure of magnetic fields in Ap stars and explore the stellar magnetic topology without introducing any global a priori constraints on the field structure. The complex magnetic model of 53 Cam derived with our magnetic Doppler imaging method achieves a good fit to the observed intensity, circular and linear polarization profiles of strong magnetically sensitive Fe II spectral lines. Such an agreement between observations and model predictions was not possible with any earlier multipolar magnetic models, based on modelling Stokes I spectra and fitting surface averaged magnetic observables (e.g., longitudinal field, magnetic field modulus, etc.). Furthermore, we demonstrate that even the direct inversion of the four Stokes parameters of 53 Cam assuming a low-order multipolar magnetic geometry is incapable of achieving an adequate fit to our spectropolarimetric observations. Thus, as a main result of our investigation, we discover that the magnetic field topology of 53 Cam is considerably more complex than any low-order multipolar expansion, raising a general question about the validity of the multipolar assumption in the studies of magnetic field structures of Ap stars. In addition to the analysis of the magnetic field of 53 Cam, we reconstruct surface abundance distributions of Si, Ca, Ti, Fe and Nd. These abundance maps confirm results of the previous studies of 53 Cam, in particular dramatic antiphase variation of Ca and Ti abundances. Based on observations obtained with the Bernard Lyot telescope of the Pic du Midi Observatory and Isaac Newton Telescope of the La Palma Observatory.
Transverse tripolar stimulation of peripheral nerve: a modelling study of spatial selectivity.
Deurloo, K E; Holsheimer, J; Boom, H B
1998-01-01
Various anode-cathode configurations in a nerve cuff are modelled to predict their spatial selectivity characteristics for functional nerve stimulation. A 3D volume conductor model of a monofascicular nerve is used for the computation of stimulation-induced field potentials, whereas a cable model of myelinated nerve fibre is used for the calculation of the excitation thresholds of fibres. As well as the usual configurations (monopole, bipole, longitudinal tripole, 'steering' anode), a transverse tripolar configuration (central cathode) is examined. It is found that the transverse tripole is the only configuration giving convex recruitment contours and therefore maximises activation selectivity for a small (cylindrical) bundle of fibres in the periphery of a monofascicular nerve trunk. As the electrode configuration is changed to achieve greater selectivity, the threshold current increases. Therefore threshold currents for fibre excitation with a transverse tripole are relatively high. Inverse recruitment is less extreme than for the other configurations. The influences of several geometrical parameters and model conductivities of the transverse tripole on selectivity and threshold current are analysed. In chronic implantation, when electrodes are encapsulated by a layer of fibrous tissue, threshold currents are low, whereas the shape of the recruitment contours in transverse tripolar stimulation does not change.
The diagnosis of aortoiliac disease. A noninvasive femoral cuff technique.
Barringer, M; Poole, G V; Shircliffe, A C; Meredith, J W; Hightower, F; Plonk, G W
1983-01-01
An inexpensive femoral "cuff" developed in this noninvasive vascular laboratory allows pulse volume recordings and systolic pressure measurements of the femoral arteries. Using the parameters 1) femoral/brachial systolic pressure ratio, 2) wave amplitude, and 3) status of the dicrotic notch for assessment of results, it was found that the cuff correctly identified 59 of 62 limbs with at least 50% aortoiliac stenosis, with only two false-positive results, for an accuracy of 97%. The high, wide thigh cuff identified 57 of the 62 limbs, but had 45 false-positive results (77% accuracy). Use of the femoral "cuff" has refined the ability to identify the anatomic location of significant arterial stenoses in the lower extremities. Images Fig. 1. Fig. 2. PMID:6824373
Swarm observation of field-aligned current and electric field in multiple arc systems
NASA Astrophysics Data System (ADS)
Wu, J.; Knudsen, D. J.; Gillies, M.; Donovan, E.; Burchill, J. K.
2017-12-01
It is often thought that auroral arcs are a direct consequence of upward field-aligned currents. In fact, the relation between currents and brightness is more complicated. Multiple auroral arc systems provide and opportunity to study this relation in detail. In this study, we have identified two types of FAC configurations in multiple parallel arc systems using ground-based optical data from the THEMIS all-sky imagers (ASIs), magnetometers and electric field instruments onboard the Swarm satellites during the period from December 2013 to March 2015. In type 1 events, each arc is an intensification within a broad, unipolar current sheet and downward currents only exist outside the upward current sheet. These types of events are termed "unipolar FAC" events. In type 2 events, multiple arc systems represent a collection of multiple up/down current pairs, which are termed as "multipolar FAC" events. Comparisons of these two types of FAC events are presented with 17 "unipolar FAC" events and 12 "multipolar FAC" events. The results show that "unipolar FAC" and "multipolar FAC" events have systematic differences in terms of MLT, arc width and separation, and dependence on substorm onset time. For "unipolar FAC" events, significant electric field enhancements are shown on the edges of the broad upward current sheet. Electric field fluctuations inside the multiple arc system can be large or small. For "multipolar FAC" events, a strong correlation between magnetic and electric field indicate uniform conductance within each upward current sheet. The electrodynamical structures of multiple arc systems presented in this paper represents a step toward understanding arc generation.
Post-Newtonian factorized multipolar waveforms for spinning, nonprecessing black-hole binaries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pan, Yi; Buonanno, Alessandra; Racine, Etienne
2011-03-15
We generalize the factorized resummation of multipolar waveforms introduced by Damour, Iyer, and Nagar to spinning black holes. For a nonspinning test particle spiraling a Kerr black hole in the equatorial plane, we find that factorized multipolar amplitudes which replace the residual relativistic amplitude f{sub lm} with its lth root, {rho}{sub lm}=f{sub lm}{sup 1/l}, agree quite well with the numerical amplitudes up to the Kerr-spin value q{<=}0.95 for orbital velocities v{<=}0.4. The numerical amplitudes are computed solving the Teukolsky equation with a spectral code. The agreement for prograde orbits and large spin values of the Kerr black-hole can be furthermore » improved at high velocities by properly factoring out the lower-order post-Newtonian contributions in {rho}{sub lm}. The resummation procedure results in a better and systematic agreement between numerical and analytical amplitudes (and energy fluxes) than standard Taylor-expanded post-Newtonian approximants. This is particularly true for higher-order modes, such as (2,1), (3,3), (3,2), and (4,4), for which less spin post-Newtonian terms are known. We also extend the factorized resummation of multipolar amplitudes to generic mass-ratio, nonprecessing, spinning black holes. Lastly, in our study we employ new, recently computed, higher-order post-Newtonian terms in several subdominant modes and compute explicit expressions for the half and one-and-half post-Newtonian contributions to the odd-parity (current) and even-parity (odd) multipoles, respectively. Those results can be used to build more accurate templates for ground-based and space-based gravitational-wave detectors.« less
[Shoulder instability and rotator cuff tear].
Voigt, C; Lill, H
2009-01-01
A rotator cuff tear as a complication of anterior shoulder dislocation is well known in patients over 40 years old. The incidence of this accompanying injury correlates with the patient's age and the number of redislocations. The tear localization and dimension depend on the patient's age. To what extent these tears are a complication of shoulder dislocation is often unclear, as rotator cuff tears and glenohumeral instability interact. Reports on this combined injury pattern are rare, but based on the patient's age, activity level, and functional demand, therapeutic concepts have been devised. In active patients younger than 60 years and in cases of redislocation, both the rotator cuff tear and the capsule-labrum-ligament lesion should be reconstructed arthroscopically. In lesser active patients age 60 years or older, an isolated rotator cuff reconstruction is often sufficient to stabilize the glenohumeral joint. This treatment concept shows a predominantly good outcome.As a special form of anterior shoulder dislocation, a rotator cuff tear and a plexus brachialis lesion--the"terrible triad of the shoulder"--is described here.
Natural History of Rotator Cuff Disease and Implications on Management
Hsu, Jason
2015-01-01
Degenerative rotator cuff disease is commonly associated with ageing and is often asymptomatic. The factors related to tear progression and pain development are just now being defined through longitudinal natural history studies. The majority of studies that follow conservatively treated painful cuff tears or asymptomatic tears that are monitored at regular intervals show slow progression of tear enlargement and muscle degeneration over time. These studies have highlighted greater risks for disease progression for certain variables, such as the presence of a full-thickness tear and involvement of the anterior aspect supraspinatus tendon. Coupling the knowledge of the natural history of degenerative cuff tear progression with variables associated with greater likelihood of successful tendon healing following surgery will allow better refinement of surgical indications for rotator cuff disease. In addition, natural history studies may better define the risks of nonoperative treatment over time. This article will review pertinent literature regarding degenerative rotator cuff disease with emphasis on variables important to defining appropriate initial treatments and refining surgical indications. PMID:26726288
Ultrasound-Guided Prolotherapy with Polydeoxyribonucleotide for Painful Rotator Cuff Tendinopathy.
Ryu, Kyoungho; Ko, Dongchan; Lim, Goeun; Kim, Eugene; Lee, Sung Hyun
2018-01-01
Rotator cuff tendinopathy is a primary cause of shoulder pain and dysfunction. Several effective nonsurgical treatment methods have been described for chronic rotator cuff tendinopathy. Prolotherapy with polydeoxyribonucleotide (PDRN), which consists of active deoxyribonucleotide polymers that stimulate tissue repair, is a nonsurgical regenerative injection that may be a viable treatment option. The objective of this study was to assess the efficacy of PDRN in the treatment of chronic rotator cuff tendinopathy. The records of patients with chronic rotator cuff tendinopathy ( n =131) were reviewed retrospectively, and the patients treated with PDRN prolotherapy ( n =32) were selected. We measured the main outcome of the shoulder pain and disability index score on a numerical rating scale of average shoulder pain. Compared with baseline data, significant improvements in the shoulder pain and disability index and pain visual analog scale scores were demonstrated at one week after the end of treatment, and at one month and three months later. PDRN prolotherapy may improve the conservative treatment of painful rotator cuff tendinopathy for a specific subset of patients.
Shamsudin, Aminudin; Lam, Patrick H; Peters, Karin; Rubenis, Imants; Hackett, Lisa; Murrell, George A C
2015-03-01
Symptomatic rotator cuff tears are often treated surgically. However, there is a paucity of information regarding the outcomes of revision arthroscopic rotator cuff repairs. To evaluate the outcome of revision arthroscopic rotator cuff surgery when compared with primary arthroscopic rotator cuff surgery in a large cohort of patients. Cohort study; Level of evidence, 3. A consecutive series of 50 revision arthroscopic rotator cuff repairs performed by a single surgeon, with minimum 2-year follow-up, were retrospectively reviewed using prospectively collected data. As a comparison, 3 primary arthroscopic rotator cuff repair cases (primary group; n = 310) were chosen immediately before each revision case, and 3 were chosen after. Standardized patient-ranked outcomes, examiner-determined assessments, and ultrasound-determined rotator cuff integrity were assessed preoperatively at 6 months and at a minimum of 2 years after surgery. The revision group was older (mean age, 63 years; range, 43-80 years) compared with the primary group (mean age, 60 years; range, 18-88 years) (P < .05) and had larger tear size (mean ± SEM) (4.1 ± 0.5 cm(2)) compared with the primary group (3.0 ± 0.2 cm(2)) (P < .05). Two years after surgery, the primary group reported less pain at rest (P < .02), during sleep (P < .05), and with overhead activity (P < .01) compared with the revision group. The primary group had better passive forward flexion (+13°; P < .05), abduction (+18°; P < .01), internal rotation (+2 vertebral levels; P < .001) and also significantly greater supraspinatus strength (+15 N; P < .001), lift-off strength (+9.3 N; P < .05), and adduction strength (+20 N; P < .01) compared with the revision group at 2 years. When compared with the primary group, the revision group was more satisfied with the overall shoulder function before surgery but was less satisfied with their shoulder function than the primary group at 2 years (P < .005). The retear rate for primary rotator cuff repair was 16% at 6 months and 21% at 2 years, while the retear rate for revision rotator cuff repair was 28% at 6 months and deteriorated to 40% at 2 years (P < .05). The short-term clinical outcomes of patients undergoing revision rotator cuff repair were similar to those after primary rotator cuff repair. However, these results did not persist, and by 2 years patients who had revision rotator cuff repair were twice as likely to have retorn compared with those undergoing primary repair. The increase in retear rate in the revision group at 2 years was associated with increased pain, impaired overhead function, less passive motion, weaker strength, and less overall satisfaction with shoulder function. © 2014 The Author(s).
Tripolar mitosis in human cells and embryos: occurrence, pathophysiology and medical implications.
Kalatova, Beata; Jesenska, Renata; Hlinka, Daniel; Dudas, Marek
2015-01-01
Tripolar mitosis is a specific case of cell division driven by typical molecular mechanisms of mitosis, but resulting in three daughter cells instead of the usual count of two. Other variants of multipolar mitosis show even more mitotic poles and are relatively rare. In nature, this phenomenon was frequently observed or suspected in multiple common cancers, infected cells, the placenta, and in early human embryos with impaired pregnancy-yielding potential. Artificial causes include radiation and various toxins. Here we combine several pieces of the most recent evidence for the existence of different types of multipolar mitosis in preimplantation embryos together with a detailed review of the literature. The related molecular and cellular mechanisms are discussed, including the regulation of centriole duplication, mitotic spindle biology, centromere functions, cell cycle checkpoints, mitotic autocorrection mechanisms, and the related complicating factors in healthy and affected cells, including post-mitotic cell-cell fusion often associated with multipolar cell division. Clinical relevance for oncology and embryo selection in assisted reproduction is also briefly discussed in this context. Copyright © 2014 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Kai, Li; Jun, Liu; Weiqiang, Liu
2017-07-01
In order to cover the shortage of dipole magnetic field in the magnetohydrodynamic(MHD) heat shield system, physical model of a multipolar magnetic field with central and peripheral solenoids is constructed. By employing the governing equations of three dimensional thermochemical nonequilibrium flow with electromagnetic source terms based on the low magneto-Reynolds assumption, the flow control performance of the dipole and multipolar magnetic fields are numerically simulated. To make the results comparable, two groups of cases are designed by first assuming equal stagnation magnetic induction strength and secondly assuming equal ampere-turns. Results show that, the five-magnet system, whose central polar orientation is the same with the peripheral ones, have stronger work capability and better shock control and thermal protection performance. Moreover, the five-solenoid systems are the best when the ampere-turns of the central solenoid are twice and fourth of the peripheral ones under those two circumstances respectively. Compared with the dipole magnetic field, the stagnation non-catalytic heat fluxes are decreased by a factor of 47.5% and 34.0% respectively.
Broadband reflective multi-polarization converter based on single-layer double-L-shaped metasurface
NASA Astrophysics Data System (ADS)
Mao, Chenyang; Yang, Yang; He, Xiaoxiang; Zheng, Jingming; Zhou, Chun
2017-12-01
In this paper, a broadband reflective multi-polarization converter based on single-layer double-L-shaped metasurface is proposed. The proposed metasurface can effectively convert linear-polarized (TE/TM) incident wave into the reflected wave with three different polarizations within the frequency bands of 5.5-22.75 GHz. Based on the electric and magnetic resonant features of the double-L-shaped structure, the proposed metasurface can convert linearly polarized waves into cross-polarized waves at three resonant frequency bands. Furthermore, the incident linearly polarized waves can be effectively converted into left/right handed circular-polarized (LHCP and RHCP) waves at other four non-resonance frequency bands. Thus, the proposed metasurface can be regarded as a seven-band multi-polarization converter. The prototype of the proposed polarization converter is analyzed and measured. Both simulated and measured results show the 3-dB axis ratio bandwidth of circular polarization bands and the high polarization conversion efficiency of cross-polarization bands when the incident wave changes from 0° to 30° at both TE and TM modes.
Winans, Amy M; Collins, Sean R; Meyer, Tobias
2016-01-01
Many developing neurons transition through a multi-polar state with many competing neurites before assuming a unipolar state with one axon and multiple dendrites. Hallmarks of the multi-polar state are large fluctuations in microtubule-based transport into and outgrowth of different neurites, although what drives these fluctuations remains elusive. We show that actin waves, which stochastically migrate from the cell body towards neurite tips, direct microtubule-based transport during the multi-polar state. Our data argue for a mechanical control system whereby actin waves transiently widen the neurite shaft to allow increased microtubule polymerization to direct Kinesin-based transport and create bursts of neurite extension. Actin waves also require microtubule polymerization, arguing that positive feedback links these two components. We propose that actin waves create large stochastic fluctuations in microtubule-based transport and neurite outgrowth, promoting competition between neurites as they explore the environment until sufficient external cues can direct one to become the axon. DOI: http://dx.doi.org/10.7554/eLife.12387.001 PMID:26836307
21 CFR 870.1120 - Blood pressure cuff.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure cuff. 870.1120 Section 870.1120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff...
Morihara, Toru; Kida, Yoshikazu; Furukawa, Ryuhei; Sukenari, Tsuyoshi; Kabuto, Yukichi; Kurokawa, Masao; Fujiwara, Hiroyoshi; Kubo, Toshikazu
2018-05-01
In cases of the large or massive rotator cuff tears, retear rates after rotator cuff repairs remain high. We introduced an arthroscopic-assisted modified Debeyre-Patte procedure which enables to decrease the tension of torn rotator cuff by sliding supraspinatus and infraspinatus laterally keeping fascia connection to the rhomboids. The objective of this study was to examine the clinical outcomes and retear rates after an arthroscopic-assisted modified Debeyre-Patte procedure for irreparable large and massive rotator cuff tears. Thirty-three rotator cuff tear patients (34 shoulders) were selected. These patients underwent arthroscopic-assisted modified Debeyre-Patte procedures and were observed postoperatively for at least 24 months. Magnetic resonance imaging (MRI) was used to evaluate the preoperative location of the torn rotator cuff stump and fatty infiltration of the muscles composing the rotator cuff, as well as the repaired rotator cuffs. Shoulder functional evaluations through the use of the Constant and Murley scores and the University of California Los Angeles (UCLA) shoulder score were compared before and after surgery, and the preoperative global fatty degeneration index (GFDI) was compared between retear and healed shoulders. MRI showed that 77% of shoulders were healed and 23% exhibited retear postoperatively. The mean preoperative GFDI was 1.99 among the 26 healed shoulders and 2.54 among the 8 retear shoulders (p < .05). When the Goutallier's classification was grade 3 or lower for all 3 cuff muscles for fatty infiltration, the retear rate was 14.3%. The mean Constant and Murley scores in healed and retear groups respectively improved from 34.7 ± 15.8, 30.0 ± 15.1 points (p = 0.47) preoperatively to 70.8 ± 8.3, 53.9 ± 14.0 points (p < .001), and UCLA scores in healed and retear groups from 13.8 ± 3.9, 12.4 ± 5.0 points (p = 0.46) preoperatively to 32.8 ± 2.7, 28.4 ± 3.6 points (p < .001). The clinical outcomes of healed shoulders after the arthroscopic-assisted modified Debeyre-Patte procedure were favorable. If the torn rotator cuff stump is retracted near the glenoid fossa, and the rotator cuff muscle scored Goutallier grade 3 or lower, this modified Debeyre-Patte procedure would be a viable option. Copyright © 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Muscle fibers are injured at the time of acute and chronic rotator cuff repair.
Davis, Max E; Stafford, Patrick L; Jergenson, Matthew J; Bedi, Asheesh; Mendias, Christopher L
2015-01-01
Rotator cuff tears are a common source of shoulder pain and disability. Even after surgical repair, some patients continue to have reduced function and progression of fatty degeneration. Because patients with chronic cuff tears often experience muscle shortening, it is possible that repairing the tendon to its anatomic footprint induces a stretch-induced muscle injury that could contribute to failures of the repair and perhaps ongoing pain. We hypothesized that, compared with acutely torn and repaired muscles, the stretch that is required to repair a chronically torn cuff would result in more muscle fiber damage. Specifically, we asked: (1) Is there muscle fiber damage that occurs from repair of an acutely torn rotator cuff and does it vary by location in the muscle; and (2) is the damage greater in the case of repair of a chronic injury? We used an open surgical approach to create a full-thickness rotator cuff tear in rats, and measured changes in muscle mass, length, and the number of fibers containing the membrane impermeable Evans Blue Dye after acute (1 day) or chronic (28 days) cuff tear or repair in rats. Differences between groups were tested using a one-way ANOVA followed by Tukey's post hoc sorting. Chronic tears resulted in 24% to 35% decreases in mass and a 20% decrease in length. The repair of acutely and chronically torn muscles resulted in damage to 90% of fibers in the distal portion of the muscle. In the proximal portion, no differences between the acutely torn and repaired groups and controls were observed, whereas repairing the chronically torn group resulted in injury to almost 70% of fibers. In a rat model, marked injury to muscle fibers is induced when the tendons of torn rotator cuffs are repaired to their anatomic footprint. In this animal model, we found that repair of chronically torn cuff muscles results in extensive injury throughout the muscle. Based on these findings, we posit that inducing a widespread injury at the time of surgical repair of chronically torn rotator cuff muscles may contribute to the problems of failed repairs or continued progression of fatty degeneration that is observed in some patients that undergo rotator cuff repair. Therapeutic interventions to protect muscle fiber membranes potentially could enhance outcomes for patients undergoing rotator cuff repair. To evaluate this, future studies that evaluate the use of membrane sealing compounds or drugs that upregulate endogenous membrane-sealing proteins are warranted.
[A design and study of a novel electronic device for cuff-pressure monitoring].
Wang, Shupeng; Li, Wei; Li, Wen; Song, Dejing; Chen, Desheng; Duan, Jun; Li, Chen; Li, Gang
2017-06-01
To design a novel electronic device for measuring the pressure in the cuff of the artificial airway; and to study the advantage of this device on continuous and intermittent cuff pressure monitoring. (1) a portable electronic device for cuff pressure measurement was invented, which could turn pressure signal into electrical signal through a pressure transducer. Meantime, it was possible to avoid pressure leak from the joint and the inside of the apparatus by modified Luer taper and sophisticated design. If the cuff pressure was out of the normal range, the apparatus could release a sound and light alarm. (2) Six traditional mechanical manometers were used to determine the cuff pressure in 6 tracheal tubes. The cuff pressure was maintain at 30 cmH 2 O (1 cmH 2 O = 0.098 kPa) by the manometer first, and repeated every 30 seconds for 4 times. (3) Study of continuous cuff pressure monitoring: We used a random number generator to randomize 6 tracheal tubes, 6 mechanical manometers and 6 our products by number 1-6, which has the same number of a group. Every group was further randomized into two balanced groups, one group used the mechanical manometer first, and the other used our product first. The baseline pressure was 30 cmH 2 O, measurement was performed every 4 hours for 6 times. When traditional mechanical manometer was used for cuff pressure monitoring, cuff pressure was decreased by an average of 2.9 cmH 2 O for each measurement (F = 728.2, P = 0.000). In study of continually monitoring, at each monitoring point, the pressure measured by electronic manometer was higher than the mechanical manometer. All the pressures measured by mechanical manometer were dropped below 20 cmH 2 O at 8th hour, and there was no pressure decrease below 20 cmH 2 O measured by electronic manometer in 24 hours by contrast. In study of intermittent monitoring, the same result was found. The pressure was dropped significantly with time when measured by mechanical manometer (F = 61.795, P = 0.000), the drops below 20 cmH 2 O began at 8th hour; but when measured by electronic manometer, all the value stayed unchanged around the baseline in 24 hours (F = 0.511, P = 0.796). Compared with traditional mechanical manometer, cuff pressures monitored by our novel electronic manometer were steadier in both continuous and intermittent monitoring. The device is compact and convenient, and can provide a good solution for continuously monitor of the tracheal cuff pressure.
A system for the automatic measurement and digital display of systolic and diastolic blood pressures
NASA Technical Reports Server (NTRS)
Schulze, A. E.
1971-01-01
Basic components of system are - occluding cuff with mounted cuff microscope, cuff pump deflator, pressure transducer, preamplifier unit, electrocardiograph machine, an analog to digital convertor unit, and digital display unit. System utilizes indirect auscultatory method, based on Korotkoff sounds, for measurement.
Rotator Cuff Disease and Injury--Evaluation and Management.
ERIC Educational Resources Information Center
Williams, Randy
This presentation considers the incidence, evaluation, and management of rotator cuff disease and injury. Pathogenesis, symptoms, physical findings, treatment (therapeutic and surgical), and prevention are discussed. It is noted that rotator cuff problems, common in athletes, are usually related to an error in training or lack of training. They…
Brand, Jefferson C
2016-03-01
In "Risk Factors for Infection After Rotator Cuff Repair," B. G. Vopat et al. report a lower rate of postoperative infection with an arthroscopic rotator cuff repair than with an open or mini-open approach. Although there were only 14 infections (infection rate of 0.77%), the reason for the preponderance of male patients, 13 of the 14 infections, needs further research to determine effective preventive strategies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Dilisio, Matthew F.; Miller, Lindsay R.; Higgins, Laurence D.
2014-01-01
Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness. PMID:25473606
Dilisio, Matthew F; Miller, Lindsay R; Higgins, Laurence D
2014-10-01
Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness.
Patch-Augmented Rotator Cuff Repair and Superior Capsule Reconstruction
Petri, M.; Greenspoon, J.A.; Moulton, S.G.; Millett, P.J.
2016-01-01
Background: Massive rotator cuff tears in active patients with minimal glenohumeral arthritis remain a particular challenge for the treating surgeon. Methods: A selective literature search was performed and personal surgical experiences are reported. Results: For patients with irreparable rotator cuff tears, a reverse shoulder arthroplasty or a tendon transfer are often performed. However, both procedures have rather high complication rates and debatable long-term results, particularly in younger patients. Therefore, patch-augmented rotator cuff repair or superior capsule reconstruction (SCR) have been recently developed as arthroscopically applicable treatment options, with promising biomechanical and early clinical results. Conclusion: For younger patients with irreparable rotator cuff tears wishing to avoid tendon transfers or reverse total shoulder arthroplasty, both patch-augmentation and SCR represent treatment options that may delay the need for more invasive surgery. PMID:27708733
Edwards, Peter; Ebert, Jay; Joss, Brendan; Bhabra, Gev; Ackland, Tim; Wang, Allan
2016-01-01
The incidence of rotator cuff tears increases with age, with full-thickness rotator cuff tears present in approximately 25% of individuals in their sixties, and more than 50% of those in their eighties. While surgery is considered an effective treatment, recurrent tears at the insertion site are common, especially with degenerative tears, which are frequent in the older population. More recently, there has been increasing interest in exercise rehabilitation and physical therapy as a means to manage partial and full thickness tears of the rotator cuff by addressing weakness and functional deficits. Recent studies have suggested that patients opting for physical therapy have demonstrated high satisfaction, an improvement in function, and success in avoiding surgery. When considering the increasing rate of shoulder surgery and the associated economic and social burden rotator cuff surgery places on both the patient and the health care system, non-surgical management such as physical therapy and exercise may, in selected cases, be a treatment alternative to surgical repair. The purpose of this clinical commentary is to provide an overview of rotator cuff pathology and pathogenesis, and to present an evidence-based case for the role of conservative rehabilitation in the management of rotator cuff injuries. Level of Evidence Level 5 PMID:27104061
Kim, Do Hoon; Jang, Young Hoon; Choi, Young Eun; Lee, Hwa-Ryeong; Kim, Sae Hoon
2016-11-01
Repair tension of a torn rotator cuff can affect healing after repair. However, a measurement of the actual tension during arthroscopic rotator cuff repair is not feasible. The relationship between repair tension and healing of a rotator cuff repair remains unclear. The purpose of this study was to evaluate the effect of repair tension on healing at the repair site. The hypothesis was that repair tension would be a major factor in determining the anatomic outcome of rotator cuff repair. Cohort study; Level of evidence, 2. Arthroscopic rotator cuff repairs (132 patients) for full-thickness rotator cuff tears were analyzed. An intraoperative model was designed for the estimation of repair tension using a tensiometer. Magnetic resonance imaging (MRI) was performed approximately 1 year (mean [±SD], 12.7 ± 3.2 months) postoperatively for the evaluation of healing at the repair site. Multivariable analysis was performed for tear size, amount of retraction, and fatty degeneration (FD) of rotator cuff muscles. The mean repair tension measured during the arthroscopic procedure was 28.5 ± 23.1 N. There was a statistically significant correlation between tension and tear size (Pearson correlation coefficient [PCC], 0.529; P < .001), amount of retraction (PCC, 0.619; P < .001), and FD of the supraspinatus (Spearman correlation coefficient [SCC], 0.308; P < .001) and infraspinatus (SCC, 0.332; P < .001). At the final follow-up (12.7 ± 3.2 months), healing failure was observed in 18.2% (24/132), and repair tension also showed a significant inverse correlation with healing at the repair site (SCC, 0.195; P = .025). However, when sex, age, tear size, amount of retraction, tendon quality, and FD of rotator cuff muscles were included for multivariable logistic regression analysis, only FD of the infraspinatus showed an association with the anatomic outcome of repair (Exp(B) = 0.596; P = .010). Our intraoperative model for the estimation of rotator cuff repair tension showed an inverse correlation of repair tension with healing at the repair site, suggesting that complete healing is less likely with high-tension repairs. A significant association was observed on MRI between a high level of FD of the infraspinatus and repaired tendon integrity. © 2016 The Author(s).
Gravitational polarizability of black holes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damour, Thibault; Lecian, Orchidea Maria; APC, UMR 7164 du CNRS, Universite Paris 7, 10, rue Alice Domon et Leonie Duquet, 75205 Paris Cedex 13
The gravitational polarizability properties of black holes are compared and contrasted with their electromagnetic polarizability properties. The 'shape' or 'height' multipolar Love numbers h{sub l} of a black hole are defined and computed. They are then compared to their electromagnetic analogs h{sub l}{sup EM}. The Love numbers h{sub l} give the height of the lth multipolar 'tidal bulge' raised on the horizon of a black hole by faraway masses. We also discuss the shape of the tidal bulge raised by a test-mass m, in the limit where m gets very close to the horizon.
NASA Astrophysics Data System (ADS)
Ullah, Kaleem; Liu, Xuefeng; Krasnok, Alex; Habib, Muhammad; Song, Li; Garcia-Camara, Braulio
2018-07-01
In this work, we show the spatial distribution of the scattered electromagnetic field of dielectric particles by using a new super-resolution method based on polarization modulation. Applying this technique, we were able to resolve the multipolar distribution of a Cu2O particle with a radius of 450 nm. In addition, FDTD and Mie simulations have been carried out to validate and confirm the experimental results. The results are helpful to understand the resonant modes of dielectric submicron particles which have a broad range of potential applications, such as all-optical devices or nanoantennas.
Charousset, Christophe; Zaoui, Amine; Bellaïche, Laurence; Piterman, Michel
2014-04-01
To evaluate the clinical and magnetic resonance imaging (MRI) outcome of arthroscopic rotator cuff repair with the use of leukocyte-platelet-rich plasma (L-PRP) in patients with large or massive rotator cuff tears. A comparative cohort of patients with large or massive rotator cuff tears undergoing arthroscopic repair was studied. Two consecutive groups of patients were included: rotator cuff repairs with L-PRP injection (group 1, n = 35) and rotator cuff repairs without L-PRP injection (group 2, n = 35). A double-row cross-suture cuff repair was performed by a single surgeon with the same rehabilitation protocol. Patients were clinically evaluated with the Constant score; Simple Shoulder Test score; University of California, Los Angeles (UCLA) score; and strength measurements by use of a handheld dynamometer. Rotator cuff healing was evaluated by postoperative MRI using the Sugaya classification (type 1 to type 5). We prospectively evaluated the 2 groups at a minimum 2-year follow-up. The results did not show differences in cuff healing between the 2 groups (P = .16). The size of recurrent tears (type 4 v type 5), however, was significantly smaller in group 1 (P = .008). There was no statistically significant difference in the recurrent tear rate (types 4 and 5) between the 2 groups (P = .65). There was no significant difference between group 1 and group 2 in terms of University of California, Los Angeles score (29.1 and 30.3, respectively; P = .90); Simple Shoulder Test score (9.9 and 10.2, respectively; P = .94); Constant score (77.3 and 78.1, respectively; P = .82); and strength (7.5 and 7.0, respectively; P = .51). In our study the use of autologous L-PRP did not improve the quality of tendon healing in patients undergoing arthroscopic repair of large or massive rotator cuff tears based on postoperative MRI evaluation. The only significant advantage was that the L-PRP patients had smaller iterative tears. However, the functional outcome was similar in the 2 groups of patients. Level III, case-control study. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
User-independent assessment of conditioning pain modulation by cuff pressure algometry.
Graven-Nielsen, T; Izumi, M; Petersen, K K; Arendt-Nielsen, L
2017-03-01
The use of conditioning pain modulation (CPM) is hampered by poor reproducibility and lack of user-independent paradigms. This study refined the CPM paradigm by applying user-independent cuff algometry. In 20 subjects, the CPM effect of conditioning with cuff stimulation on the arm was investigated by pain test stimuli on the contralateral leg before and in parallel with different cuff conditionings (10, 30, 60 kPa/60 s; 30, 60 kPa/10 s). As test stimulus, another cuff was inflated (1 kPa/s) until the subjects detected the pain tolerance threshold (PTT) during which the pain detection threshold (PDT) and the pressure at a pain intensity of 6 cm on a 10-cm visual analogue scale (PVAS6) were extracted. For comparison, pressure pain thresholds (PPTs) as test stimuli were recorded by the user-dependent handheld pressure algometry. Combinations of cuff locations for conditioning (pain intensity standardized) and contralateral test stimuli were additionally evaluated (leg-arm, leg-leg, arm-thigh). The test-retest reliability in two sessions 1 month apart was assessed in five CPM protocols. In all protocols, the PDT, PVAS6 and PTT increased during conditioning compared with baseline (p < 0.05). The CPM effect (i.e. conditioning minus baseline) for PVAS6, PTT and PPT increased for increasing conditioning intensities (p < 0.05). The CPM effects were not significantly different for changes in conditioning durations or conditioning/test stimulus locations. In two sessions, the CPM effects for PVAS6 and PTT assessed after 60 s of conditioning on the leg/thigh showed the highest intra-class correlations (0.47-0.73), where they were 0.04-0.6 for PPTs. The user-independent cuff algometry is reliable for CPM assessment and for supra-pain threshold test stimuli better than the user-dependent technology. A user-independent CPM technique where the conditioning is controlled by one cuff stimulation, and the test-stimulus is provided by another cuff stimulation. This study shows that cuff algometry is reliable for CPM assessment. © 2016 European Pain Federation - EFIC®.
The cost-effectiveness of single-row compared with double-row arthroscopic rotator cuff repair.
Genuario, James W; Donegan, Ryan P; Hamman, Daniel; Bell, John-Erik; Boublik, Martin; Schlegel, Theodore; Tosteson, Anna N A
2012-08-01
Interest in double-row techniques for arthroscopic rotator cuff repair has increased over the last several years, presumably because of a combination of literature demonstrating superior biomechanical characteristics and recent improvements in instrumentation and technique. As a result of the increasing focus on value-based health-care delivery, orthopaedic surgeons must understand the cost implications of this practice. The purpose of this study was to examine the cost-effectiveness of double-row arthroscopic rotator cuff repair compared with traditional single-row repair. A decision-analytic model was constructed to assess the cost-effectiveness of double-row arthroscopic rotator cuff repair compared with single-row repair on the basis of the cost per quality-adjusted life year gained. Two cohorts of patients (one with a tear of <3 cm and the other with a tear of ≥3 cm) were evaluated. Probabilities for retear and persistent symptoms, health utilities for the particular health states, and the direct costs for rotator cuff repair were derived from the orthopaedic literature and institutional data. The incremental cost-effectiveness ratio for double-row compared with single-row arthroscopic rotator cuff repair was $571,500 for rotator cuff tears of <3 cm and $460,200 for rotator cuff tears of ≥3 cm. The rate of radiographic or symptomatic retear alone did not influence cost-effectiveness results. If the increase in the cost of double-row repair was less than $287 for small or moderate tears and less than $352 for large or massive tears compared with the cost of single-row repair, then double-row repair would represent a cost-effective surgical alternative. On the basis of currently available data, double-row rotator cuff repair is not cost-effective for any size rotator cuff tears. However, variability in the values for costs and probability of retear can have a profound effect on the results of the model and may create an environment in which double-row repair becomes the more cost-effective surgical option. The identification of the threshold values in this study may help surgeons to determine the most cost-effective treatment.
Mihata, Teruhisa; Watanabe, Chisato; Fukunishi, Kunimoto; Ohue, Mutsumi; Tsujimura, Tomoyuki; Fujiwara, Kenta; Kinoshita, Mitsuo
2011-10-01
Although previous biomechanical research has demonstrated the superiority of the suture-bridge rotator cuff repair over double-row repair from a mechanical point of view, no articles have described the structural and functional outcomes of this type of procedure. The structural and functional outcomes after arthroscopic rotator cuff repair may be different between the single-row, double-row, and combined double-row and suture-bridge (compression double-row) techniques. Cohort study; Level of evidence, 3. There were 206 shoulders in 201 patients with full-thickness rotator cuff tears that underwent arthroscopic rotator cuff repair. Eleven patients were lost to follow-up. Sixty-five shoulders were repaired using the single-row, 23 shoulders using the double-row, and 107 shoulders using the compression double-row techniques. Clinical outcomes were evaluated at an average of 38.5 months (range, 24-74 months) after rotator cuff repair. Postoperative cuff integrity was determined using Sugaya's classification of magnetic resonance imaging (MRI). The retear rates after arthroscopic rotator cuff repair were 10.8%, 26.1%, and 4.7%, respectively, for the single-row, double-row, and compression double-row techniques. In the subcategory of large and massive rotator cuff tears, the retear rate in the compression double-row group (3 of 40 shoulders, 7.5%) was significantly less than those in the single-row group (5 of 8 shoulders, 62.5%, P < .001) and the double-row group (5 of 12 shoulders, 41.7%, P < .01). Postoperative clinical outcomes in patients with a retear were significantly lower than those in patients without a retear for all 3 techniques. The additional suture bridges decreased the retear rate for large and massive tears. The combination of the double-row and suture-bridge techniques, which had the lowest rate of postoperative retear, is an effective option for arthroscopic repair of the rotator cuff tendons because the postoperative functional outcome in patients with a retear is inferior to that without retear.
Jensen, Andrew R; Kelley, Benjamin V; Mosich, Gina M; Ariniello, Allison; Eliasberg, Claire D; Vu, Brandon; Shah, Paras; Devana, Sai K; Murray, Iain R; Péault, Bruno; Dar, Ayelet; Petrigliano, Frank A
2018-04-10
After massive tears, rotator cuff muscle often undergoes atrophy, fibrosis, and fatty degeneration. These changes can lead to high surgical failure rates and poor patient outcomes. The identity of the progenitor cells involved in these processes has not been fully elucidated. Platelet-derived growth factor receptor β (PDGFRβ) and platelet-derived growth factor receptor α (PDGFRα) have previously been recognized as markers of cells involved in muscle fibroadipogenesis. We hypothesized that PDGFRα expression identifies a fibroadipogenic subset of PDGFRβ + progenitor cells that contribute to fibroadipogenesis of the rotator cuff. We created massive rotator cuff tears in a transgenic strain of mice that allows PDGFRβ + cells to be tracked via green fluorescent protein (GFP) fluorescence. We then harvested rotator cuff muscle tissues at multiple time points postoperatively and analyzed them for the presence and localization of GFP + PDGFRβ + PDGFRα + cells. We cultured, induced, and treated these cells with the molecular inhibitor CWHM-12 to assess fibrosis inhibition. GFP + PDGFRβ + PDGFRα + cells were present in rotator cuff muscle tissue and, after massive tears, localized to fibrotic and adipogenic tissues. The frequency of PDGFRβ + PDGFRα + cells increased at 5 days after massive cuff tears and decreased to basal levels within 2 weeks. PDGFRβ + PDGFRα + cells were highly adipogenic and significantly more fibrogenic than PDGFRβ + PDGFRα - cells in vitro and localized to adipogenic and fibrotic tissues in vivo. Treatment with CWHM-12 significantly decreased fibrogenesis from PDGFRβ + PDGFRα + cells. PDGFRβ + PDGFRα + cells directly contribute to fibrosis and fatty degeneration after massive rotator cuff tears in the mouse model. In addition, CWHM-12 treatment inhibits fibrogenesis from PDGFRβ + PDGFRα + cells in vitro. Clinically, perioperative PDGFRβ + PDGFRα + cell inhibition may limit rotator cuff tissue degeneration and, ultimately, improve surgical outcomes for massive rotator cuff tears. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Oh, Joo Han; McGarry, Michelle H; Jun, Bong Jae; Gupta, Akash; Chung, Kyung Chil; Hwang, James; Lee, Thay Q
2012-11-01
Complete repair in massive rotator cuff tear may not be possible, allowing for only partial repair. However, the effect of partial repair on glenohumeral biomechanics has not been evaluated. Therefore, the purpose of this study was to compare the rotational range of motion (ROM), glenohumeral kinematics, and gap formation at the repaired tendon edge following massive cuff tear and repair according to the degree of repair completion. Posterior fixation will restore the altered biomechanics of massive rotator cuff tear. Controlled laboratory study. Eight cadaveric shoulders were tested at 0°, 30°, and 60° of abduction in the scapular plane. Muscle loading was applied based on physiological muscle cross-sectional area ratios. Maximum internal (MaxIR) and external rotations (MaxER) were measured. Humeral head apex (HHA) position and gap formation at the repaired tendon edge were measured using a MicroScribe from MaxIR to MaxER in 30° increments. Testing was performed for intact, massive cuff tear, complete repair, and 4 types of partial repair. A repeated-measures analysis of variance was used to determine significant differences. Massive tear significantly increased ROM and shifted HHA superiorly in MaxIR at all abduction angles (P < .05). The complete repair restored ROM to intact (P < .05), while all partial repairs did not. Abnormal HHA elevation due to massive tear was restored by all repairs (P < .05). Release of the anterior single row alone and release of the marginal convergence significantly increased gap formation at the anterior tendon edge (P < .05). This study emphasizes the importance of anterior fixation in massive cuff tear to restore rotational range of motion and decrease gap formation at the repaired tendon edge and of posterior fixation to restore abnormal glenohumeral kinematics due to massive cuff tear. If complete repair of massive cuff tear is not possible, posterior cuff (infraspinatus) repair is necessary to restore abnormal glenohumeral kinematics, and margin convergence anteriorly is recommended to decrease gap formation of the repaired tendon edge, which may provide a better biomechanical environment for healing.
Clinical effects of thigh cuffs during a 7-day 6° head-down bed rest
NASA Astrophysics Data System (ADS)
Pavy-Le Traon, Anne; Maillet, Alain; Vasseur Clausen, Pascale; Custaud, Marc-Antoine; Alferova, Irina; Gharib, Claude; Fortrat, Jacques-Olivier
2001-08-01
Thigh cuffs are used by Russian cosmonauts to limit the fluid shift induced by space flight. A ground simulation using the head-down bed rest (HDBR) model was performed to assess the effects of thigh cuffs on clinical tolerance and orthostatic adaptation. 8 male healthy volunteers (32.4±1.9 years) participated twice in a 7-day HDBR — one time with thigh cuffs (worm daily from 9 am to 7 pm) (TC) and one time without (WTC). Orthostatic tolerance was assessed by a 10 minute stand test and by a LBNP test (5 min at -15, -30, -45 mmHg) before (BDC-1) and at the end of the HDBR period (R+1). Plasma volume was measured before and at the end of HDBR by the Evans blue dye dilution technique. Thigh cuffs limits headache due to fluid shift, as well as the loss in plasma volume (TC: -5.85±0.95%; WTC: -9.09±0.82%, p<0.05). The mean duration of the stand test (R+1) did not differ in the two group (TC 7.1±1.3 min; WTC 7.0±1.0 min). The increase in HR and decrease in diastolic blood pressure were slightly but significantly larger without thigh cuffs. Duration of the LBNP tests did not differ with thigh cuffs. Thigh cuffs limit the symptoms due to fluid shift and the loss in plasma volume. They partly reduced the increase in HR during orthostatic stress but had no effect on duration of orthostatic stress tests.
Iwata, Eiichiro; Shigematsu, Hideki; Inoue, Kazuya; Egawa, Takuya; Sakamoto, Yoshihiro; Tanaka, Yasuhito
2017-01-01
Rotator cuff tears and cervical spondylotic amyotrophy (CSA) are often confused as the main symptom in those with difficulty in shoulder elevation. Empty and full can tests are frequently used for the clinical diagnosis of rotator cuff tears. The aim of the present study was to investigate whether the empty and full can test results can help differentiate rotator cuff tears from CSA. Twenty-seven consecutive patients with rotator cuff tears and 25 with CSA were enrolled. We prospectively performed empty and full can tests in patients with rotator cuff tears and CSA. The following signs were considered positive: (a) muscle weakness during the empty can test, (b) muscle weakness during the full can test, (c) pain provocation during the empty can test, and (d) pain provocation during the full can test. We calculated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of rotator cuff tears for each positive finding. The sensitivity and specificity of each index were as follows (sensitivity, specificity, PPV, NPV): (a) 77.8%, 0%, 45.7%, 0%; (b) 66.7%, 4.0%, 42.9%, 10.0%; (c) 88.9%, 96.0%, 96.0%, 88.9%; and (d) 74.1%, 96.0%, 95.2%, 77.4%. There were significant differences for each index. Muscle weakness during the empty and full can tests was not useful in differentiating rotator cuff tears from CSA because of low specificity and PPV. However, pain provocation was useful in differentiating these two conditions because of high specificity and PPV.
Dierckman, Brian D; Ni, Jake J; Karzel, Ronald P; Getelman, Mark H
2018-01-01
This study evaluated the repair integrity and patient clinical outcomes following arthroscopic rotator cuff repair of medium to large rotator cuff tears using a single-row technique consisting of medially based, triple-loaded anchors augmented with bone marrow vents in the rotator cuff footprint lateral to the repair. This is a retrospective study of 52 patients (53 shoulders) comprising 36 males and 16 females with a median age of 62 (range 44-82) with more than 24-month follow-up, tears between 2 and 4 cm in the anterior-posterior dimension and utilizing triple-loaded anchors. Mann-Whitney test compared Western Ontario Rotator Cuff (WORC) outcome scores between patients with healed and re-torn cuff repairs. Multivariate logistic regression analysed association of variables with healing status and WORC score. Cuff integrity was assessed on MRI, read by a musculoskeletal fellowship-trained radiologist. Magnetic resonance imaging (MRI) demonstrated an intact repair in 48 of 53 shoulders (91%). The overall median WORC score was 95.7 (range 27.6-100.0). A significant difference in WORC scores were seen between patients with healed repairs 96.7 (range 56.7-100.0) compared with a re-tear 64.6 (27.6-73.8), p < 0.00056. Arthroscopic repair of medium to large rotator cuff tears using a triple-loaded single-row repair augmented with bone marrow vents resulted in a 91% healing rate by MRI and excellent patient reported clinical outcomes comparable to similar reported results in the literature. IV.
Ostrander, Roger V; McKinney, Bart I
2012-10-01
Studies suggest that arthroscopic repair techniques may have high recurrence rates for larger rotator cuff tears. A more anatomic repair may improve the success rate when performing arthroscopic rotator cuff repair. We hypothesized that a triple-row modification of the suture-bridge technique for rotator cuff repair would result in significantly more footprint contact area and pressure between the rotator cuff and the humeral tuberosity. Eighteen ovine infraspinatus tendons were repaired using 1 of 3 simulated arthroscopic techniques: a double-row repair, the suture-bridge technique, and a triple-row repair. The triple-row repair technique is a modification of the suture-bridge technique that uses an additional reducing anchor between the medial and lateral rows. Six samples were tested per group. Pressure-indicating film was used to measure the footprint contact area and pressure after each repair. The triple-row repair resulted in significantly more rotator cuff footprint contact area and contact pressure compared with the double-row technique and the standard suture-bridge technique. No statistical difference in contact area or contact pressure was found between the double-row technique and the suture-bridge technique. The triple-row technique for rotator cuff repair results in significantly more footprint contact area and contact pressure compared with the double-row and standard suture-bridge techniques. This more anatomic repair may improve the healing rate when performing arthroscopic rotator cuff repair. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Relationship of ABO Blood Type on Rotator Cuff Tears.
Lee, Doo-Hyung; Lee, Han-Dong; Yoon, Seung-Hyun
2015-11-01
ABO blood groups are associated with various diseases. A relationship between Achilles tendon ruptures and blood type O has been reported, although its pathogenesis was not clear. To the best of our knowledge, there is no published study describing the relationship between blood type and rotator cuff tendon tears. To determine whether patients with rotator cuff tear had a greater prevalence of blood type O than those without rotator cuff tear. A cross-sectional study. Research hospital outpatient evaluation. A total of 316 subjects with shoulder pain were included and divided into "tear" and "no-tear" groups according to ultrasonographic examination. ABO blood group, gender, dominant arm, smoking history, trauma history, and age were compared between the 2 groups and the odds ratios of these factors were evaluated by logistic regression. The tear group (38.6%) had more instances of blood type O than the healthy population (27.2%; P = .002). The adjusted odds ratio for rotator cuff tear for blood type O to non-O was 2.38 (95% confidence interval 1.28-4.42). The odds ratios for rotator cuff tears for smoking, major trauma history, minor trauma history, and age were 2.08, 3.11, 2.29, and 1.06, respectively. Patients with rotator cuff tears were more likely to have blood type O. The odds ratios of factors for rotator cuff tears were high in the following order: major trauma history, blood type O, minor trauma history, and age. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Increasing age and tear size reduce rotator cuff repair healing rate at 1 year.
Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J
2017-12-01
Background and purpose - There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods - Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results - The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation - Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor.
Improper tube fixation causing a leaky cuff.
Gupta, Babita; Farooque, Kamran; Jain, Divya; Kapoor, Rakesh
2010-04-01
Leaking endotracheal tube cuffs are common problems in intensive care units. We report a case wherein the inflation tube was damaged by the adhesive plaster used for tube fixation and resulted in leaking endotracheal tube cuff. We also give some suggestions regarding the tube fixation and some remedial measures for damaged inflation system.
The effect of glenoid cavity depth on rotator cuff tendinitis.
Malkoc, Melih; Korkmaz, Ozgur; Ormeci, Tugrul; Sever, Cem; Kara, Adna; Mahirogulları, Mahir
2016-03-01
Some of the most important causes of shoulder pain are inflammation and degenerative changes in the rotator cuff (RC). Magnetic resonance imaging (MRI) is a noninvasive and safe imaging modality. MRI can be used for the evaluation of cuff tendinopathy. In this study, we evaluated the relationship between glenoid cavity depth and cuff tendinopathy and we investigated glenoid cavity depth on the pathogenesis of cuff tendinopathy. We retrospectively evaluated 215 patients who underwent MRI. Of these, 60 patients showed cuff tendinopathy (group A) and 54 patients showed no pathology (group B). Glenoid cavity depth was calculated in the coronal and transverse planes. The mean axial depth was 1.7 ± 0.9 and the mean coronal depth 3.8 ± 0.9, for group A. The mean axial depth was 3.5 ± 0.7 and the mean coronal depth 1.5 ± 0.8, for group B. There were significant differences in the axial and coronal depths between the two groups. High coronal and low axial depth of the glenoid cavity can be used to diagnose RC tendinitis.
NASA Astrophysics Data System (ADS)
Deng, Zhipeng; Liang, Fuyou
2016-10-01
An inflatable cuff wrapped around the upper arm is widely used in noninvasive blood pressure measurement. However, the mechanical interaction between cuff and arm tissues, a factor that potentially affects the accuracy of noninvasive blood pressure measurement, remains rarely addressed. In the present study, finite element (FE) models were constructed to quantify intra-arm stresses generated by cuff compression, aiming to provide some theoretical evidence for identifying factors of importance for blood pressure measurement or explaining clinical observations. Obtained results showed that the simulated tissue stresses were highly sensitive to the distribution of cuff pressure on the arm surface and the contact condition between muscle and bone. In contrast, the magnitude of cuff pressure and small variations in elastic properties of arm soft tissues had little influence on the efficiency of pressure transmission in arm tissues. In particular, it was found that a thickened subcutaneous fat layer in obese subjects significantly reduced the effective pressure transmitted to the brachial artery, which may explain why blood pressure overestimation occurs more frequently in obese subjects in noninvasive blood pressure measurement.
Leakage of fluid around endotracheal tube cuffs: a cadaver study
Lucius, Ralph; Ewald, Kristian
2013-01-01
Background The aim of the study was to evaluate the leakage of liquid past the cuffs of tracheal tubes in fresh frozen human heads. Methods Six truncated fresh frozen heads were used and intubated with 8.0 mm endotracheal tubes. The intracuff pressures tested were 30 and 100 cmH2O. Subsequently, 20 ml of each of two oral antiseptic rinses (0.2% chlorhexidine and octenidine [octenidol®, Schülke & Mayr GmbH, Norderstedt, Germany]) was applied for thirty seconds in the mouth. During the trial, leakage of the cuffs was examined. Results The sealing between the tracheal cuff and tracheal wall was leakage-proof for all tested intracuff pressures and all tested antiseptic rinses. However, approximately 5.6 ml and 1.8 ml leaked into the esophagus and remained as a cuff-puddle, respectively. Conclusions The sealing between an endotracheal tube cuff with an intracuff pressure of 30 cmH2O and the tracheal wall is leakage-proof during oral care with antiseptic rinsing. An increase of intracuff pressure to 100 cmH2O does not appear to be required. PMID:24363847
Andreas Vesalius' five hundreth anniversary: initiation of the rotator cuff concept.
Brinkman, Romy J; Hage, J Joris
2015-12-01
The rotator cuff concept refers to the four scapulohumeral muscles that stabilize and rotate the humerus relative to the scapula. To date, the first description of the rotator cuff remained unidentified. In light of the 500th birthday of Andreas Vesalius (1515-1564) we searched his 1543 masterwork "Fabrica Corporis Humani Libri Septem" for references to the morphology and function of the rotator cuff muscles. Even though he distinguished three rather than four scapulohumeral muscles, Vesalius recognized the need for structures that prevent dislocation of the shoulder inherent to the morphology of the humeral caput and scapular socket. He recorded "three strong ligaments" and the "three muscles that rotate the arm" of which the tendons completely "embrace the ligaments of the joint" as such structures. Vesalius defined the rotator cuff concept avant la lettre.
Weiss, M; Dullenkopf, A; Gerber, A C
2004-01-01
Principles and characteristics of the recently introduced Microcuff paediatric tracheal tube (Microcuff, GmbH, Weinheim, Germany) with anatomically based depth markings, cuff-free subglottic tube shaft and short high volume-low pressure cuff with ultrathin cuff membrane are presented. First available tubes (ID 4.0 mm) were evaluated regarding cuff pressures required to seal the trachea and regarding the distance from the tube tip to the carina. After obtaining approval of the local ethical committee, 20 children aged 2-4 years, receiving tracheal intubation under general anaesthesia with muscle paralysis, were included. The tubes were placed during direct laryngoscopy and the glottic depth marking placed between the vocal cords. Cuff pressure to prevent audible air leakage at standardised ventilator settings (PIP 20 cm H(2)O/PEEP 5 cm H(2)O/RR20 x min(-1)) was assessed by means of a cuff pressure manometer within 5 min after intubation. Subsequently, the distance from the tube tip to the tracheal carina was measured by means of fibre bronchoscopy. Data are presented as the median (range). Patient age was 3.0 years (2.0-3.9 years), weight 13.5 kg (9.1-19.2 kg) and body length 95 cm (79-105 cm). The lowest cuff pressure required to seal the trachea ranged from 4-14 cmH(2)O (median 10 cm H(2)O), the distance from tube tip to tracheal carina was to 2.9 cm (2.0-4.5 cm). The new Microcuff paediatric tracheal tube with ultrathin high volume-low pressure cuff required tracheal sealing pressures below tracheal wall pressures usually required with uncuffed tracheal tubes for efficient sealing and ventilation at 20 cm H(2)O peak inspiratory pressure. The distance from the tube tip to carina was in the safe range in all patients.
Does the Rotator Cuff Tear Pattern Influence Clinical Outcomes After Surgical Repair?
Watson, Scott; Allen, Benjamin; Robbins, Chris; Bedi, Asheesh; Gagnier, Joel J.; Miller, Bruce
2018-01-01
Background: Limited literature exists regarding the influence of rotator cuff tear morphology on patient outcomes. Purpose: To determine the effect of rotator cuff tear pattern (crescent, U-shape, L-shape) on patient-reported outcomes after rotator cuff repair. Study Design: Cohort study; Level of evidence, 3. Methods: Patients undergoing arthroscopic repair of known full-thickness rotator cuff tears were observed prospectively at regular intervals from baseline to 1 year. The tear pattern was classified at the time of surgery as crescent, U-shaped, or L-shaped. Primary outcome measures were the Western Ontario Rotator Cuff Index (WORC), the American Shoulder and Elbow Surgeons (ASES), and a visual analog scale (VAS) for pain. The tear pattern was evaluated as the primary predictor while controlling for variables known to affect rotator cuff outcomes. Mixed-methods regression and analysis of variance (ANOVA) were used to examine the effects of tear morphology on patient-reported outcomes after surgical repair from baseline to 1 year. Results: A total of 82 patients were included in the study (53 male, 29 female; mean age, 58 years [range, 41-75 years]). A crescent shape was the most common tear pattern (54%), followed by U-shaped (25%) and L-shaped tears (21%). There were no significant differences in outcome scores between the 3 groups at baseline. All 3 groups showed statistically significant improvement from baseline to 1 year, but analysis failed to show any predictive effect in the change in outcome scores from baseline to 1 year for the WORC, ASES, or VAS when tear pattern was the primary predictor. Further ANOVA also failed to show any significant difference in the change in outcome scores from baseline to 1 year for the WORC (P = .96), ASES (P = .71), or VAS (P = .86). Conclusion: Rotator cuff tear pattern is not a predictor of functional outcomes after arthroscopic rotator cuff repair. PMID:29623283
Boorman, Richard S; More, Kristie D; Hollinshead, Robert M; Wiley, James P; Mohtadi, Nicholas G; Lo, Ian K Y; Brett, Kelly R
2018-03-01
The purpose of this study was to examine 5-year outcomes in a prospective cohort of patients previously enrolled in a nonoperative rotator cuff tear treatment program. Patients with chronic (>3 months), full-thickness rotator cuff tears (demonstrated on imaging) who were referred to 1 of 2 senior shoulder surgeons were enrolled in the study between October 2008 and September 2010. They participated in a comprehensive, nonoperative, home-based treatment program. After 3 months, the outcome in these patients was defined as "successful" or "failed." Patients in the successful group were essentially asymptomatic and did not require surgery. Patients in the failed group were symptomatic and consented to undergo surgical repair. All patients were followed up at 1 year, 2 years, and 5 or more years. At 5 or more years, all patients were contacted for follow-up; the response rate was 84%. Approximately 75% of patients remained successfully treated with nonoperative treatment at 5 years and reported a mean rotator cuff quality-of-life index score of 83 of 100 (SD, 16). Furthermore, between 2 and 5 years, only 3 patients who had previously been defined as having a successful outcome became more symptomatic and underwent surgical rotator cuff repair. Those in whom nonoperative treatment had failed and who underwent surgical repair had a mean rotator cuff quality-of-life index score of 89 (SD, 11) at 5-year follow-up. The operative and nonoperative groups at 5-year follow-up were not significantly different (P = .11). Nonoperative treatment is an effective and lasting option for many patients with a chronic, full-thickness rotator cuff tear. While some clinicians may argue that nonoperative treatment delays inevitable surgical repair, our study shows that patients can do very well over time. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Does the Rotator Cuff Tear Pattern Influence Clinical Outcomes After Surgical Repair?
Watson, Scott; Allen, Benjamin; Robbins, Chris; Bedi, Asheesh; Gagnier, Joel J; Miller, Bruce
2018-03-01
Limited literature exists regarding the influence of rotator cuff tear morphology on patient outcomes. To determine the effect of rotator cuff tear pattern (crescent, U-shape, L-shape) on patient-reported outcomes after rotator cuff repair. Cohort study; Level of evidence, 3. Patients undergoing arthroscopic repair of known full-thickness rotator cuff tears were observed prospectively at regular intervals from baseline to 1 year. The tear pattern was classified at the time of surgery as crescent, U-shaped, or L-shaped. Primary outcome measures were the Western Ontario Rotator Cuff Index (WORC), the American Shoulder and Elbow Surgeons (ASES), and a visual analog scale (VAS) for pain. The tear pattern was evaluated as the primary predictor while controlling for variables known to affect rotator cuff outcomes. Mixed-methods regression and analysis of variance (ANOVA) were used to examine the effects of tear morphology on patient-reported outcomes after surgical repair from baseline to 1 year. A total of 82 patients were included in the study (53 male, 29 female; mean age, 58 years [range, 41-75 years]). A crescent shape was the most common tear pattern (54%), followed by U-shaped (25%) and L-shaped tears (21%). There were no significant differences in outcome scores between the 3 groups at baseline. All 3 groups showed statistically significant improvement from baseline to 1 year, but analysis failed to show any predictive effect in the change in outcome scores from baseline to 1 year for the WORC, ASES, or VAS when tear pattern was the primary predictor. Further ANOVA also failed to show any significant difference in the change in outcome scores from baseline to 1 year for the WORC ( P = .96), ASES ( P = .71), or VAS ( P = .86). Rotator cuff tear pattern is not a predictor of functional outcomes after arthroscopic rotator cuff repair.
In Vivo Shoulder Function After Surgical Repair of a Torn Rotator Cuff
Bey, Michael J.; Peltz, Cathryn D.; Ciarelli, Kristin; Kline, Stephanie K.; Divine, George W.; van Holsbeeck, Marnix; Muh, Stephanie; Kolowich, Patricia A.; Lock, Terrence R.; Moutzouros, Vasilios
2015-01-01
Background Surgical repair of a torn rotator cuff is based on the belief that repairing the tear is necessary to restore normal glenohumeral joint (GHJ) mechanics and achieve a satisfactory clinical outcome. Hypothesis Dynamic joint function is not completely restored by rotator cuff repair, thus compromising shoulder function and potentially leading to long-term disability. Study Design Controlled laboratory study and Case series; Level of evidence, 4. Methods Twenty-one rotator cuff patients and 35 control participants enrolled in the study. Biplane radiographic images were acquired bilaterally from each patient during coronal-plane abduction. Rotator cuff patients were tested at 3, 12, and 24 months after repair of a supraspinatus tendon tear. Control participants were tested once. Glenohumeral joint kinematics and joint contact patterns were accurately determined from the biplane radiographic images. Isometric shoulder strength and patient-reported outcomes were measured at each time point. Ultrasound imaging assessed rotator cuff integrity at 24 months after surgery. Results Twenty of 21 rotator cuff repairs appeared intact at 24 months after surgery. The humerus of the patients’ repaired shoulder was positioned more superiorly on the glenoid than both the patients’ contralateral shoulder and the dominant shoulder of control participants. Patient-reported outcomes improved significantly over time. Shoulder strength also increased over time, although strength deficits persisted at 24 months for most patients. Changes over time in GHJ mechanics were not detected for either the rotator cuff patients’ repaired or contralateral shoulders. Clinical outcome was associated with shoulder strength but not GHJ mechanics. Conclusion Surgical repair of an isolated supraspinatus tear may be sufficient to keep the torn rotator cuff intact and achieve satisfactory patient-reported outcomes, but GHJ mechanics and shoulder strength are not fully restored with current repair techniques. Clinical Relevance The study suggests that current surgical repair techniques may be effective for reducing pain but have not yet been optimized for restoring long-term shoulder function. PMID:21737834
Oh, Joo Han; Jun, Bong Jae; McGarry, Michelle H; Lee, Thay Q
2011-11-16
It is unknown at which stage of rotator cuff tear the biomechanical environment is altered. The purpose of this study was to determine if a critical rotator cuff tear stage exists that alters glenohumeral joint biomechanics throughout the rotational range of shoulder motion, and to evaluate the biomechanical effect of parascapular muscle-loading. Eight cadaver shoulders were used with a custom testing system. Four progressive rotator cuff tear stages were investigated on the basis of footprint anatomy. Three muscle-loading conditions were examined: rotator cuff only; rotator cuff with deltoid muscle; and rotator cuff, deltoid, pectoralis major, and latissimus dorsi muscles. Testing was performed in the scapular plane with 0°, 30°, and 60° of shoulder abduction. The maximum internal and external rotations were measured with 3.4 Nm of torque. The position of the humeral head apex with respect to the glenoid was calculated with use of a MicroScribe 3DLX digitizing system throughout the rotational range of motion. The abduction capability was determined as the abduction angle achieved with increasing deltoid load. Tear of the entire supraspinatus tendon significantly increased maximum external rotation and significantly decreased abduction capability with higher deltoid loads (p < 0.05). Tear of the entire supraspinatus tendon and half of the infraspinatus tendon significantly shifted the humeral head apex posteriorly at the midrange of rotation and superiorly at maximum internal rotation (p < 0.05). Loading the pectoralis major and latissimus dorsi muscles decreased the amount of humeral head elevation due to deltoid loading. Tear of the entire supraspinatus tendon was the critical stage for increasing rotational range of shoulder motion and for decreased abduction capability. Further tear progression to the infraspinatus muscle was the critical stage for significant changes in humeral head kinematics. The pectoralis major and latissimus dorsi muscles played an important role in stabilizing the humeral head as the rotator cuff tear progressed.
Gaur, Pallavi; Ubale, Pravin; Khadanga, Prashant
2017-01-01
We wished to compare the endotracheal tube (ETT) cuff pressure inflated with air or alkalinized lignocaine during anesthesia and evaluate clinical symptoms such as coughing and sore throat (postoperative sore throat [POST]) following tracheal extubation. This was a prospective randomized controlled study conducted in a tertiary care set up over a period of 1 year. We included 100 patients in age group of 18-65 years posted for elective surgeries of duration more than 90 min under general anesthesia with N 2 O-O 2 mixture. Patients were randomized using computer-generated randomization table into air and lignocaine group. The ETT cuff was inflated with air or alkalinized lignocaine (2% lignocaine with 7.5% sodium bicarbonate, in the proportions of 19.0:1.0 ml) to the volume that prevented air leak using cuff pressure manometer. After extubation, an independent observer blinded to study group recorded the presence or absence of coughing and POST at immediately, 1 h and 24 h postoperatively. Demographic data, baseline characteristics (American Society of Anesthesiologists grade, intracuff volume/cuff pressure at start of surgery), and duration of anesthesia were comparable among study groups ( P > 0.05). Cuff pressure and volume achieved in the end of surgery were much higher in air group as compared to lignocaine group ( P < 0.05). Incidence of coughing and POST at immediately, 1 h and 24 h postoperatively was significantly higher in air group compared to lignocaine group. Impact of duration of anesthesia on rise in cuff pressure was significantly higher in air group and its effect on cuff-induced laryngotracheal morbidity was significant in both air and lignocaine group. This study showed the significance of use of alkalinized 2% lignocaine in prevention of rise of cuff pressure and incidence of coughing and POST. Duration of anesthesia has also a significant effect on incidence of postoperative trachea-laryngeal morbidity.
Sherman, Seth L
2018-01-01
Transosseous equivalent rotator cuff repair is an expensive construct that has demonstrated biomechanical superiority when compared with other rotator cuff repair techniques. A novel transosseous knotless repair that substitutes medial row anchors for a transosseous tunnel rivals the biomechanical advantages of transosseous equivalent rotator cuff repair at half the cost and with reduced dependence on bone quality. Surgeons should carefully consider if "knotless transosseous is more." Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Swarm Observation of Field-Aligned Currents Associated With Multiple Auroral Arc Systems
NASA Astrophysics Data System (ADS)
Wu, J.; Knudsen, D. J.; Gillies, D. M.; Donovan, E. F.; Burchill, J. K.
2017-10-01
Auroral arcs occur in regions of upward field-aligned currents (FACs); however, the relation is not one to one, since kinetic energy of the current-carrying electrons is also important in the production of auroral luminosity. Multiple auroral arc systems provide an opportunity to study the relation between FACs and auroral brightness in detail. In this study, we have identified two types of FAC configurations in multiple parallel arc systems using ground-based optical data from the Time History of Events and Macroscale Interactions during Substorms all-sky imagers, magnetometers and electric field instruments on board the Swarm satellites. In "unipolar FAC" events, each arc is an intensification within a broad, unipolar current sheet and downward return currents occur outside of this broad sheet. In "multipolar FAC" events, multiple arc systems represent a collection of multiple up/down current pairs. By collecting 17 events with unipolar FAC and 12 events with multipolar FACs, we find that (1) unipolar FAC events occur most frequently between 20 and 21 magnetic local time and multipolar FAC events tend to occur around local midnight and within 1 h after substorm onset. (2) Arcs in unipolar FAC systems have a typical width of 10-20 km and a spacing of 25-50 km. Arcs in multipolar FAC systems are wider and more separated. (3) Upward currents with more arcs embedded have larger intensities and widths. (4) Electric fields are strong and highly structured on the edges of multiple arc system with unipolar FAC. The fact that arcs with unipolar FAC are much more highly structured than the associated currents suggests that arc multiplicity is indicative not of a structured generator deep in the magnetosphere, but rather of the magnetosphere-ionosphere coupling process.
Multipolar moments of weak lensing signal around clusters. Weighing filaments in harmonic space
NASA Astrophysics Data System (ADS)
Gouin, C.; Gavazzi, R.; Codis, S.; Pichon, C.; Peirani, S.; Dubois, Y.
2017-09-01
Context. Upcoming weak lensing surveys such as Euclid will provide an unprecedented opportunity to quantify the geometry and topology of the cosmic web, in particular in the vicinity of lensing clusters. Aims: Understanding the connectivity of the cosmic web with unbiased mass tracers, such as weak lensing, is of prime importance to probe the underlying cosmology, seek dynamical signatures of dark matter, and quantify environmental effects on galaxy formation. Methods: Mock catalogues of galaxy clusters are extracted from the N-body PLUS simulation. For each cluster, the aperture multipolar moments of the convergence are calculated in two annuli (inside and outside the virial radius). By stacking their modulus, a statistical estimator is built to characterise the angular mass distribution around clusters. The moments are compared to predictions from perturbation theory and spherical collapse. Results: The main weakly chromatic excess of multipolar power on large scales is understood as arising from the contraction of the primordial cosmic web driven by the growing potential well of the cluster. Besides this boost, the quadrupole prevails in the cluster (ellipsoidal) core, while at the outskirts, harmonic distortions are spread on small angular modes, and trace the non-linear sharpening of the filamentary structures. Predictions for the signal amplitude as a function of the cluster-centric distance, mass, and redshift are presented. The prospects of measuring this signal are estimated for current and future lensing data sets. Conclusions: The Euclid mission should provide all the necessary information for studying the cosmic evolution of the connectivity of the cosmic web around lensing clusters using multipolar moments and probing unique signatures of, for example, baryons and warm dark matter.
Rational Design of Orthogonal Multipolar Interactions with Fluorine in Protein–Ligand Complexes
Pollock, Jonathan; Borkin, Dmitry; Lund, George; ...
2015-08-19
Multipolar interactions involving fluorine and the protein backbone have been frequently observed in protein–ligand complexes. Such fluorine–backbone interactions may substantially contribute to the high affinity of small molecule inhibitors. Here we found that introduction of trifluoromethyl groups into two different sites in the thienopyrimidine class of menin–MLL inhibitors considerably improved their inhibitory activity. In both cases, trifluoromethyl groups are engaged in short interactions with the backbone of menin. In order to understand the effect of fluorine, we synthesized a series of analogues by systematically changing the number of fluorine atoms, and we determined high-resolution crystal structures of the complexes withmore » menin. Here, we found that introduction of fluorine at favorable geometry for interactions with backbone carbonyls may improve the activity of menin–MLL inhibitors as much as 5- to 10-fold. In order to facilitate the design of multipolar fluorine–backbone interactions in protein–ligand complexes, we developed a computational algorithm named FMAP, which calculates fluorophilic sites in proximity to the protein backbone. We demonstrated that FMAP could be used to rationalize improvement in the activity of known protein inhibitors upon introduction of fluorine. Furthermore, FMAP may also represent a valuable tool for designing new fluorine substitutions and support ligand optimization in drug discovery projects. Analysis of the menin–MLL inhibitor complexes revealed that the backbone in secondary structures is particularly accessible to the interactions with fluorine. Lastly, considering that secondary structure elements are frequently exposed at protein interfaces, we postulate that multipolar fluorine–backbone interactions may represent a particularly attractive approach to improve inhibitors of protein–protein interactions.« less
NASA Astrophysics Data System (ADS)
Fisher, Lee E.; Ayers, Christopher A.; Ciollaro, Mattia; Ventura, Valérie; Weber, Douglas J.; Gaunt, Robert A.
2014-06-01
Objective. This study describes results of primary afferent neural microstimulation experiments using microelectrode arrays implanted chronically in the lumbar dorsal root ganglia (DRG) of four cats. The goal was to test the stability and selectivity of these microelectrode arrays as a potential interface for restoration of somatosensory feedback after damage to the nervous system such as amputation. Approach. A five-contact nerve-cuff electrode implanted on the sciatic nerve was used to record the antidromic compound action potential response to DRG microstimulation (2-15 µA biphasic pulses, 200 µs cathodal pulse width), and the threshold for eliciting a response was tracked over time. Recorded responses were segregated based on conduction velocity to determine thresholds for recruiting Group I and Group II/Aβ primary afferent fibers. Main results. Thresholds were initially low (5.1 ± 2.3 µA for Group I and 6.3 ± 2.0 µA for Group II/Aβ) and increased over time. Additionally the number of electrodes with thresholds less than or equal to 15 µA decreased over time. Approximately 12% of tested electrodes continued to elicit responses at 15 µA up to 26 weeks after implantation. Higher stimulation intensities (up to 30 µA) were tested in one cat at 23 weeks post-implantation yielding responses on over 20 additional electrodes. Within the first six weeks after implantation, approximately equal numbers of electrodes elicited only Group I or Group II/Aβ responses at threshold, but the relative proportion of Group II/Aβ responses decreased over time. Significance. These results suggest that it is possible to activate Group I or Group II/Aβ primary afferent fibers in isolation with penetrating microelectrode arrays implanted in the DRG, and that those responses can be elicited up to 26 weeks after implantation, although it may be difficult to achieve a consistent response day-to-day with currently available electrode technology. The DRG are compelling targets for sensory neuroprostheses with potential to achieve recruitment of a range of sensory fiber types over multiple months after implantation.
Improved apparatus for predictive diagnosis of rotator cuff disease
NASA Astrophysics Data System (ADS)
Pillai, Anup; Hall, Brittany N.; Thigpen, Charles A.; Kwartowitz, David M.
2014-03-01
Rotator cuff disease impacts over 50% of the population over 60, with reports of incidence being as high as 90% within this population, causing pain and possible loss of function. The rotator cuff is composed of muscles and tendons that work in tandem to support the shoulder. Heavy use of these muscles can lead to rotator cuff tear, with the most common causes is age-related degeneration or sport injuries, both being a function of overuse. Tears ranges in severity from partial thickness tear to total rupture. Diagnostic techniques are based on physical assessment, detailed patient history, and medical imaging; primarily X-ray, MRI and ultrasonography are the chosen modalities for assessment. The final treatment technique and imaging modality; however, is chosen by the clinician is at their discretion. Ultrasound has been shown to have good accuracy for identification and measurement of full-thickness and partial-thickness rotator cuff tears. In this study, we report on the progress and improvement of our method of transduction and analysis of in situ measurement of rotator cuff biomechanics. We have improved the ability of the clinician to apply a uniform force to the underlying musculotendentious tissues while simultaneously obtaining the ultrasound image. This measurement protocol combined with region of interest (ROI) based image processing will help in developing a predictive diagnostic model for treatment of rotator cuff disease and help the clinicians choose the best treatment technique.
Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.
Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio
2004-06-01
It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (p<0.05) than forearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (p<0.05) than those found for forearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.
Tissue Engineering for Rotator Cuff Repair: An Evidence-Based Systematic Review
Maffulli, Nicola; Longo, Umile Giuseppe; Loppini, Mattia; Berton, Alessandra; Spiezia, Filippo; Denaro, Vincenzo
2012-01-01
The purpose of this systematic review was to address the treatment of rotator cuff tears by applying tissue engineering approaches to improve tendon healing, specifically platelet rich plasma (PRP) augmentation, stem cells, and scaffolds. Our systematic search was performed using the combination of the following terms: “rotator cuff”, “shoulder”, “PRP”, “platelet rich plasma”, “stemcells”, “scaffold”, “growth factors”, and “tissue engineering”. No level I or II studies were found on the use of scaffolds and stem cells for rotator cuff repair. Three studies compared rotator cuff repair with or without PRP augmentation. All authors performed arthroscopic rotator cuff repair with different techniques of suture anchor fixation and different PRP augmentation. The three studies found no difference in clinical rating scales and functional outcomes between PRP and control groups. Only one study showed clinical statistically significant difference between the two groups at the 3-month follow up. Any statistically significant difference in the rates of tendon rerupture between the control group and the PRP group was found using the magnetic resonance imaging. The current literature on tissue engineering application for rotator cuff repair is scanty. Comparative studies included in this review suggest that PRP augmented repair of a rotator cuff does not yield improved functional and clinical outcome compared with non-augmented repair at a medium and long-term followup. PMID:25098365
Livesey, Michael; Horneff, John G; Sholder, Daniel; Lazarus, Mark; Williams, Gerald; Namdari, Surena
2018-05-01
A well-functioning rotator cuff is necessary for successful anatomic total shoulder arthroplasty (TSA). This study evaluated patients who underwent concomitant TSA and rotator cuff repair (RCR) for functional outcomes, revision rates, and predictors of poor results. Retrospective chart review was conducted to identify patients who underwent TSA and RCR. Demographic data, rotator cuff tear and RCR characteristics, range of motion, and radiographs were recorded. Minimum 2-year functional outcomes were obtained. Predictors of reoperation and/or poor clinical results were determined. Forty-five patients met inclusion criteria (22 high-grade partial-thickness and 23 full-thickness tears). Fourteen (31%) patients were labeled as having a poor result; 8 (18%) patients required reoperation. There was a significant difference between the acromiohumeral interval preoperatively and immediately postoperatively (P=.013). However, at maximum radiographic follow-up, the acromiohumeral interval was not significantly different from preoperative values (P=.86). Patients with a preoperative acromiohumeral interval of less than 8 mm had an increased rate of cuff-related reoperation (P=.003). Although concomitant TSA and RCR is a reasonable consideration, 31% of patients had a poor clinical result. An acromiohumeral interval of less than 8 mm was a predictor of cuff-related reoperation and may be an indication to consider reverse arthroplasty in the setting of joint arthrosis with a rotator cuff tear. [Orthopedics. 2018; 41(3):e334-e339.]. Copyright 2018, SLACK Incorporated.
[Rotator cuff repair: single- vs double-row. Clinical and biomechanical results].
Baums, M H; Kostuj, T; Klinger, H-M; Papalia, R
2016-02-01
The goal of rotator cuff repair is a high initial mechanical stability as a requirement for adequate biological recovery of the tendon-to-bone complex. Notwithstanding the significant increase in publications concerning the topic of rotator cuff repair, there are still controversies regarding surgical technique. The aim of this work is to present an overview of the recently published results of biomechanical and clinical studies on rotator cuff repair using single- and double-row techniques. The review is based on a selective literature research of PubMed, Embase, and the Cochrane Database on the subject of the clinical and biomechanical results of single- and double-row repair. In general, neither the biomechanical nor the clinical evidence can recommend the use of a double-row concept for the treatment for every rotator cuff tear. Only tears of more than 3 cm seem to benefit from better results on both imaging and in clinical outcome studies compared with the use of single-row techniques. Despite a significant increase in publications on the surgical treatment of rotator cuff tears in recent years, the clinical results were not significantly improved in the literature so far. Unique information and algorithms, from which the optimal treatment of this entity can be derived, are still inadequate. Because of the cost-effectiveness and the currently vague evidence, the double-row techniques cannot be generally recommended for the repair of all rotator cuff tears.
Bernhardsson, Susanne; Klintberg, Ingrid Hultenheim; Wendt, Gunilla Kjellby
2011-01-01
To evaluate the effect on pain intensity and function of an exercise concept focusing on specific eccentric strength training of the rotator cuff in patients with subacromial impingement syndrome. Single-subject research design with baseline and treatment phases (AB design). Home-based training programme supervised and supported by visits to physiotherapy clinic. Ten patients, mean (SD) age 54 (8.6) years, symptom duration 12 (9.1) months. Daily eccentric strengthening exercises of the rotator cuff during 12 weeks. Pain intensity, assessed with a visual analogue scale, and function, using the Patient-Specific Functional Scale. Shoulder function evaluated with the Constant score, and shoulder-related quality of life evaluated with the Western Ontario Rotator Cuff Index. Pain intensity decreased significantly in eight of the ten subjects. Function improved significantly in all ten subjects. Constant score increased in nine subjects and Western Ontario Rotator Cuff Index increased in seven subjects. Mean Constant score for the whole group increased significantly from 44 to 69 points (P = 0.008). Mean Western Ontario Rotator Cuff Index increased from 51 to 71% (P = 0.021). A 12-week eccentric strengthening programme targeting the rotator cuff and incorporating scapular control and correct movement pattern can be effective in decreasing pain and increasing function in patients with subacromial impingement syndrome. A randomized controlled trial is necessary to provide stronger evidence of the method.
No prosthetic management of massive and irreparable rotator cuff tears
Garofalo, Raffaele; Cesari, Eugenio
2014-01-01
A massive rotator cuff tear is not necessarily irreparable. Number of tendons involved, muscle-tendon unit quality, and decreased acromionhumeral distance (AHD) are as important as tear size in determining reparability of lesion. Massive and irreparable rotator cuff tears cannot be anatomically repaired to the bone and are a common source of pain and disability even in middle-aged patients. In these patients when conservative management has failed, it is possible to perform different surgical techniques. A functional repair can help to restore the horizontal force couple of the cuff on the humeral head and to increase the AHD. Debridement of irreparable tears and biceps tenotomy or tenodesis can have a role in low functional demand patients but results deteriorate over time. Recently, several commercially available tissue-engineered biological and synthetic scaffolds have been developed to augment rotator cuff repairs. The aim is to provide a mechanical improvement in case of poor quality tissue at time zero and give a support to have a better cuff healing. In selected cases, the scaffold can be used also to bridge tendon defect. Patients who not have pseudoparalysis, cuff tear arthropathy and with intact deltoid function can benefit from tendon transfers with satisfactory outcomes. These different procedures should be chosen for each patient with selected criteria and after a satisfactory explanation about the really possible expectation after surgery. PMID:27582930
Cerciello, Simone; Monk, Andrew Paul; Visonà, Enrico; Carbone, Stefano; Edwards, Thomas Bradley; Maffulli, Nicola; Walch, Gilles
2017-07-01
Secondary cuff failure after shoulder replacement is disabling and often requires additional surgery. Increased critical shoulder angle (CSA) has been found in patients with cuff tear compared to normal subjects. The interobserver reliability of the CSA and the relationship between CSA and symptomatic secondary cuff failure after shoulder replacement were investigated. Nineteen patients with symptomatic cuff failure after anatomic shoulder replacement (mean FU 45 months) were compared to a control group of 29 patients showing no signs of symptomatic cuff failure (mean FU 105.7 months). The CSA was measured by two blinded surgeons at a mean follow-up of 45 and 105.7 months, respectively. Inter-observer reliability was calculated. The mean CSA in the study group in neutral, internal and external rotations were 33°, 34° and 34°, respectively. Corresponding values in the control group were 32°, 32° and 32°. The interclass correlation coefficient for the whole population between the two examiners were 0.956 (P < 0.01), 0.964 (P < 0.01) and 0.955 (P < 0.01), respectively. There were no significant differences of CSA values between patients who had undergone shoulder replacement and experienced late cuff failure and those in whom the same procedure had been successful. A good inter-observer reliability was found for the CSA method.
EGR1 induces tenogenic differentiation of tendon stem cells and promotes rabbit rotator cuff repair.
Tao, Xu; Liu, Junpeng; Chen, Lei; Zhou, You; Tang, Kanglai
2015-01-01
The rate of healing failure after surgical repair of chronic rotator cuff tears is considerably high. The aim of this study was to investigate the function of the zinc finger transcription factor early growth response 1 (EGR1) in the differentiation of tendon stem cells (TSCs) and in tendon formation, healing, and tendon tear repair using an animal model of rotator cuff repair. Tenocyte, adipocyte, osteocyte, and chondrocyte differentiation as well as the expression of related genes were determined in EGR1-overexpressing TSCs (EGR1-TSCs) using tissue-specific staining, immunofluorescence staining, quantitative PCR, and western blotting. A rabbit rotator cuff repair model was established, and TSCs and EGR1-TSCs in a fibrin glue carrier were applied onto repair sites. The rabbits were sacrificed 8 weeks after repair operation, and tissues were histologically evaluated and tenocyte-related gene expression was determined. EGR1 induced tenogenic differentiation of TSCs and inhibited non-tenocyte differentiation of TSCs. Furthermore, EGR1 promoted tendon repair in a rabbit model of rotator cuff injury. The BMP12/Smad1/5/8 signaling pathway was involved in EGR1-induced tenogenic differentiation and rotator cuff tendon repair. EGR1 plays a key role in tendon formation, healing, and repair through BMP12/Smad1/5/8 pathway. EGR1-TSCs is a promising treatment for rotator cuff tendon repair surgeries. © 2015 S. Karger AG, Basel.
[Cuff pressure control at the intersinve care unit: influence of nursing professionals' training].
Velasco Sanz, T R; Ronda Delgado de la Fuente, M; Sánchez de la Ventana, A B; Reyes Merino Martínez, M
2015-01-01
To analyze proper control of endotracheal cuff pressure in an intensive care unit. The specific objective is to verify whether training of nursing professionals improves monitoring endotracheal cuff pressure. the study type is descriptive, observational and retrospective. All patients were admitted to the Critical Unit II of the Clínico San Carlos Hospital between May 2010-November 2011, requiring either a tracheal tube or tracheal cannula. Studied variables were: number of in range measures, number of intubated patients, or with tracheal cannula and register. Four cuts were made on all admitted patients admitted during the study period in order to measure endotracheal cuff pressure. Two cuts were performed before the professional nurses training and the other two cuts after a specific training with respect to endotracheal cuff pressure and Zero pneumonia. There were 74 measurements. The first cut obtained 40.74% of measures in range. In the second cut 61.90% of measures were identified in range. In the third cut, it was found that 85.7% of measures were in range and in the fourth court, it was noted the 89.47% of measures were in range. Monitoring of the endotracheal cuff pressure was inadequate before specific training of professionals. Nursing professionals training facilitates the correct measurement of the endotracheal cuff pressure, which improves patient safety. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
El-Tawil, Sherif; Prinja, Aditya; Stanton, Jeremy
2015-01-01
We describe the first reported case of a tumour deposit within the rotator cuff presenting as a bizarre, progressive, and fixed external rotation deformity of the shoulder. It is also the first reported case to our knowledge of an oesophageal primary metastasising to the rotator cuff.
Yoshida, Masahito; Collin, Phillipe; Josseaume, Thierry; Lädermann, Alexandre; Goto, Hideyuki; Sugimoto, Katumasa; Otsuka, Takanobu
2018-01-01
Magnetic resonance (MR) imaging is common in structural and qualitative assessment of the rotator cuff post-operatively. Rotator cuff integrity has been thought to be associated with clinical outcome. The purpose of this study was to evaluate the inter-observer reliability of cuff integrity (Sugaya's classification) and assess the correlation between Sugaya's classification and the clinical outcome. It was hypothesized that Sugaya's classification would show good reliability and good correlation with the clinical outcome. Post-operative MR images were taken two years post-operatively, following arthroscopic rotator cuff repair. For assessment of inter-rater reliability, all radiographic evaluations for the supraspinatus muscle were done by two orthopaedic surgeons and one radiologist. Rotator cuff integrity was classified into five categories, according to Sugaya's classification. Fatty infiltration was graded into four categories, based on the Fuchs' classification grading system. Muscle hypotrophy was graded as four grades, according to the scale proposed by Warner. The clinical outcome was assessed according to the constant scoring system pre-operatively and 2 years post-operatively. Of the sixty-two consecutive patients with full-thickness rotator cuff tears, fifty-two patients were reviewed in this study. These subjects included twenty-three men and twenty-nine women, with an average age of fifty-seven years. In terms of the inter-rater reliability between orthopaedic surgeons, Sugaya's classification showed the highest agreement [ICC (2.1) = 0.82] for rotator cuff integrity. The grade of fatty infiltration and muscle atrophy demonstrated good agreement, respectively (0.722 and 0.758). With regard to the inter-rater reliability between orthopaedic surgeon and radiologist, Sugaya's classification showed good reliability [ICC (2.1) = 0.70]. On the other hand, fatty infiltration and muscle hypotrophy classifications demonstrated fair and moderate agreement [ICC (2.1) = 0.39 and 0.49]. Although no significant correlation was found between overall post-operative constant score and Sugaya's classification, Sugaya's classification indicated significant correlation with the muscle strength score. Sugaya's classification showed repeatability and good agreement between the orthopaedist and radiologist, who are involved in the patient care for the rotator cuff tear. Common classification of rotator cuff integrity with good reliability will give appropriate information for clinicians to improve the patient care of the rotator cuff tear. This classification also would be helpful to predict the strength of arm abduction in the scapular plane. IV.
Budoff, Jeffrey E; Lin, Cheng-Li; Hong, Chih-Kai; Chiang, Florence L; Su, Wei-Ren
2016-06-01
Coracoacromial ligament (CAL) excision and acromioplasty increase superior and anterosuperior glenohumeral translation. It is unknown how much of an increase in rotator cuff force production is required to re-establish intact glenohumeral biomechanics after these surgical procedures. We hypothesized that, after CAL excision and acromioplasty, an increase in rotator cuff force production would not be necessary to reproduce the anterosuperior and superior translations of the intact specimens. Nine cadaveric shoulders were subjected to loading in the superior and anterosuperior directions in the intact state after CAL excision, acromioplasty, and recording of the translations. The rotator cuff force was then increased to normalize glenohumeral biomechanics. After CAL excision at 150 and 200 N of loading, an increase in the rotator cuff force by 25% decreased anterosuperior translation to the point where there was no significant difference from the intact specimen's translation. After acromioplasty (and CAL excision) at 150 and 200 N, an increase in the rotator cuff force of 25% and 30%, respectively, decreased superior translation to the point where there was no significant difference from the intact specimen's translation. At 150 to 200 N of loading, CAL excision and acromioplasty increase the rotator cuff force required to maintain normal glenohumeral biomechanics by 25% to 30%. After a subacromial decompression, the rotator cuff has an increased force production requirement to maintain baseline glenohumeral mechanics. Under many circumstances, in vivo force requirements may be even greater after surgical attenuation of the coracoacromial arch. Basic Science Study; Biomechanics. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Fonseca-Reyes, Salvador; de Alba-García, Javier García; Parra-Carrillo, José Z; Paczka-Zapata, José Antonio
2003-06-01
To measure the effect on blood pressure readings when a standard cuff is used on patients with arms of a large circumference, and to determine the frequency of arms of a large circumference. Blood pressures were taken in 120 subjects with an arm circumference greater than 33 cm. Also, the arm circumference was determined in 244 patients from a family health unit, and in 216 patients from a hypertension clinic. A mercury sphygmomanometer and two different cuff sizes were used in a random sequence; therefore, 60 patients' blood pressure were first measured with a large cuff, followed by a standard cuff; the opposite sequence was then applied for another 60 patients. With the obtained values and using a regression analysis, the difference in blood pressure overestimation was calculated. Arm circumference measurement percentages were used to determine the frequency of arms of a large circumference. Both systolic and diastolic blood pressures were significantly greater when the standard cuff was used. For every 5 cm increase in arm circumference, starting at 35 cm, a 2-5 mmHg increase in systolic blood pressure, and a 1-3 mmHg increase in diastolic blood pressure was observed. The prevalence of arms with a large circumference in the family medicine unit and hypertension clinic was 42% and 41.8%, respectively. There is an overestimation of blood pressure when a standard cuff is used in obese subjects. The high prevalence of these individuals in our environment, both in the hypertensive and normotensive population, makes it necessary to have on hand different sizes of cuffs for taking blood pressure in order to avoid incorrect decisions.
An ultrasound look at Korotkoff sounds: the role of pulse wave velocity and flow turbulence.
Benmira, Amir; Perez-Martin, Antonia; Schuster, Iris; Veye, Florent; Triboulet, Jean; Berron, Nicolas; Aichoun, Isabelle; Coudray, Sarah; Laurent, Jérémy; Bereksi-Reguig, Fethi; Dauzat, Michel
2017-04-01
The aim of this study was to analyze the temporal relationships between pressure, flow, and Korotkoff sounds, providing clues for their comprehensive interpretation. When measuring blood pressure in a group of 23 volunteers, we used duplex Doppler ultrasonography to assess, under the arm-cuff, the brachial artery flow, diameter changes, and local pulse wave velocity (PWV), while recording Korotkoff sounds 10 cm downstream together with cuff pressure and ECG. The systolic (SBP) and diastolic (DBP) blood pressures were 118.8±17.7 and 65.4±10.4 mmHg, respectively (n=23). The brachial artery lumen started opening when cuff pressure decreased below the SBP and opened for an increasing length of time until cuff pressure reached the DBP, and then remained open but pulsatile. A high-energy low-frequency Doppler signal, starting a few milliseconds before flow, appeared and disappeared together with Korotkoff sounds at the SBP and DBP, respectively. Its median duration was 42.7 versus 41.1 ms for Korotkoff sounds (P=0.54; n=17). There was a 2.20±1.54 ms/mmHg decrement in the time delay between the ECG R-wave and the Korotkoff sounds during cuff deflation (n=18). The PWV was 10±4.48 m/s at null cuff pressure and showed a 0.62% decrement per mmHg when cuff pressure increased (n=13). Korotkoff sounds are associated with a high-energy low-frequency Doppler signal of identical duration, typically resulting from wall vibrations, followed by flow turbulence. Local arterial PWV decreases when cuff pressure increases. Exploiting these changes may help improve SBP assessment, which remains a challenge for oscillometric techniques.
Valencia, Mauricio; Ferrer, Miquel; Farre, Ramon; Navajas, Daniel; Badia, Joan Ramon; Nicolas, Josep Maria; Torres, Antoni
2007-06-01
The aspiration of subglottic secretions colonized by bacteria pooled around the tracheal tube cuff due to inadvertent deflation (<20 cm H2O) of the cuff plays a relevant role in the pathogenesis of ventilator-associated pneumonia. We assessed the efficacy of an automatic, validated device for the continuous regulation of tracheal tube cuff pressure in preventing ventilator-associated pneumonia. Prospective randomized controlled trial. Respiratory intensive care unit and general medical intensive care unit. One hundred and forty-two mechanically ventilated patients (age, 64 +/- 17 yrs; Acute Physiology and Chronic Health Evaluation II score, 18 +/- 6) without pneumonia or aspiration at admission. Within 24 hrs of intubation, patients were randomly allocated to undergo continuous regulation of the cuff pressure with the automatic device (n = 73) or routine care of the cuff pressure (control group, n = 69). Patients remained in a semirecumbent position in bed. The primary end point variable was the incidence of ventilator-associated pneumonia. Main causes for intubation were decreased consciousness (43, 30%) and exacerbation of chronic respiratory diseases (38, 27%). Cuff pressure <20 cm H2O was more frequently observed in the control than the automatic group (45.3 vs. 0.7% determinations, p < .001). However, the rate of ventilator-associated pneumonia with clinical criteria (16, 22% vs. 20, 29%) and microbiological confirmation (11, 15% vs. 10, 15%), the distribution of early and late onset, the causative microorganisms, and intensive care unit (20, 27% vs. 16, 23%) and hospital mortality (30, 41% vs. 23, 33%) were similar for the automatic and control groups, respectively. Cuff pressure is better controlled with the automatic device. However, it did not result in additional benefits to the semirecumbent position in preventing ventilator-associated pneumonia.
Effects of age and pathology on shear wave speed of the human rotator cuff.
Baumer, Timothy G; Dischler, Jack; Davis, Leah; Labyed, Yassin; Siegal, Daniel S; van Holsbeeck, Marnix; Moutzouros, Vasilios; Bey, Michael J
2018-01-01
Rotator cuff tears are common and often repaired surgically, but post-operative repair tissue healing, and shoulder function can be unpredictable. Tear chronicity is believed to influence clinical outcomes, but conventional clinical approaches for assessing tear chronicity are subjective. Shear wave elastography (SWE) is a promising technique for assessing soft tissue via estimates of shear wave speed (SWS), but this technique has not been used extensively on the rotator cuff. Specifically, the effects of age and pathology on rotator cuff SWS are not well known. The objectives of this study were to assess the association between SWS and age in healthy, asymptomatic subjects, and to compare measures of SWS between patients with a rotator cuff tear and healthy, asymptomatic subjects. SWE images of the supraspinatus muscle and intramuscular tendon were acquired from 19 asymptomatic subjects and 11 patients with a rotator cuff tear. Images were acquired with the supraspinatus under passive and active (i.e., minimal activation) conditions. Mean SWS was positively associated with age in the supraspinatus muscle and tendon under passive and active conditions (p ≤ 0.049). Compared to asymptomatic subjects, patients had a lower mean SWS in their muscle and tendon under active conditions (p ≤ 0.024), but no differences were detected under passive conditions (p ≥ 0.783). These findings identify the influences of age and pathology on SWS in the rotator cuff. These preliminary findings are an important step toward evaluating the clinical utility of SWE for assessing rotator cuff pathology. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:282-288, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Surgery or conservative treatment for rotator cuff tear: a meta-analysis.
Ryösä, Anssi; Laimi, Katri; Äärimaa, Ville; Lehtimäki, Kaisa; Kukkonen, Juha; Saltychev, Mikhail
2017-07-01
Comparative evidence on treating rotator cuff tear is inconclusive. The objective of this review was to evaluate the evidence on effectiveness of tendon repair in reducing pain and improving function of the shoulder when compared with conservative treatment of symptomatic rotator cuff tear. Search on CENTRAL, MEDLINE, EMBASE, CINAHL, Web of Science and Pedro databases. Randomised controlled trials (RCT) comparing surgery and conservative treatment of rotator cuff tear. Study selection and extraction based on the Cochrane Handbook for Systematic reviews of Interventions. Random effects meta-analysis. Three identified RCTs involved 252 participants (123 cases and 129 controls). The risk of bias was considered low for all three RCTs. For Constant score, statistically insignificant effect size was 5.6 (95% CI -0.41 to 11.62) points in 1-year follow up favouring surgery and below the level of minimal clinically important difference. The respective difference in pain reduction was -0.93 (95% CI -1.65 to -0.21) cm on a 0-10 pain visual analogue scale favouring surgery. The difference was statistically significant (p = 0.012) in 1-year follow up but below the level of minimal clinically important difference. There is limited evidence that surgery is not more effective in treating rotator cuff tear than conservative treatment alone. Thus, a conservative approach is advocated as the initial treatment modality. Implications for Rehabilitation There is limited evidence that surgery is not more effective in treating rotator cuff tear than conservative treatment alone. There was no clinically significant difference between surgery and active physiotherapy in 1-year follow-up in improving Constant score or reducing pain caused by rotator cuff tear. As physiotherapy is less proneness to complications and less expensive than surgery, a conservative approach is advocated as the initial treatment modality to rotator cuff tears.
Effectiveness Of Plain Shoulder Radiograph In Detecting Degenerate Rotator Cuff Tears.
Hussain, Adnan; Muzzammil, Muhammad; Butt, Faisal; Valsamis, Epaminondas Markos; Dwyer, Amitabh J
2018-01-01
Studies have demonstrated radiographic findings of sclerosis and cortical irregularity at the greater tuberosity can suggest a rotator cuff tear. Plain radiographs are the most easily attainable first-line investigations in evaluating shoulder injuries. This study determines the effectiveness in predicting degenerate rotator cuff tears by detecting radiographic changes on shoulder x-rays. Retrospective cross-sectional study with a consecutive series of patients conducted in Hinchingbrooke Hospital, Huntingdon, United Kingdom from January 2015 to June 2017. Anteroposterior shoulder radiographs of 150 symptomatic patients who underwent shoulder arthroscopy were independently analysed by surgeons who were blinded from the arthroscopic results. Patients aged fewer than 30 and over 70 years were excluded. Patients with advanced osteoarthritis and cuff tear arthropathy evident on x-rays were also excluded. Sixty-five patients included in the study had rotator cuff tears on arthroscopy. Radiographic changes were correlated with arthroscopic findings to determine this test's ability to predict degenerate rotator cuff tears. When both cortical irregularity and sclerosis were present on the plain radiograph, these signs had a sensitivity of 78.8% [95% CI 65.7, 87.8%] and specificity 77.4% [95% CI 67.2, 85.0%] with a positive predictive value of 68.3%, using contingency table analysis. The presence of cortical irregularity was found to be a better predictor of a tear as compared to sclerosis. This study concludes that plain radiograph are good modality for initial evaluation of rotator cuff tears and detecting when both cortical irregularity and sclerosis. Consideration of these radiographic findings serves as a useful adjunct in diagnostic workup and can guide subsequent investigations and treatment when evaluating rotator cuff tears of the shoulder.
The effect of a rotator cuff tear and its size on three-dimensional shoulder motion.
Kolk, Arjen; Henseler, Jan Ferdinand; de Witte, Pieter Bas; van Zwet, Erik W; van der Zwaal, Peer; Visser, Cornelis P J; Nagels, Jochem; Nelissen, Rob G H H; de Groot, Jurriaan H
2017-06-01
Rotator cuff-disease is associated with changes in kinematics, but the effect of a rotator cuff-tear and its size on shoulder kinematics is still unknown in-vivo. In this cross-sectional study, glenohumeral and scapulothoracic kinematics of the affected shoulder were evaluated using electromagnetic motion analysis in 109 patients with 1) subacromial pain syndrome (n=34), 2) an isolated supraspinatus tear (n=21), and 3) a massive rotator cuff tear involving the supraspinatus and infraspinatus (n=54). Mixed models were applied for the comparisons of shoulder kinematics between the three groups during abduction and forward flexion. In the massive rotator cuff-tear group, we found reduced glenohumeral elevation compared to the subacromial pain syndrome (16°, 95% CI [10.5, 21.2], p<0.001) and the isolated supraspinatus tear group (10°, 95% CI [4.0, 16.7], p=0.002) at 110° abduction. Reduced glenohumeral elevation in massive rotator cuff tears coincides with an increase in scapulothoracic lateral rotation compared to subacromial pain syndrome (11°, 95% CI [6.5, 15.2], p<0.001) and supraspinatus tears (7°, 95% CI [1.8, 12.1], p=0.012). Comparable differences were observed for forward flexion. No differences in glenohumeral elevation were found between the subacromial pain syndrome and isolated supraspinatus tear group during arm elevation. The massive posterosuperior rotator cuff-tear group had substantially less glenohumeral elevation and more scapulothoracic lateral rotation compared to the other groups. These observations suggest that the infraspinatus is essential to preserve glenohumeral elevation in the presence of a supraspinatus tear. Shoulder kinematics are associated with rotator cuff-tear size and may have diagnostic potential. Copyright © 2017 Elsevier Ltd. All rights reserved.
Superior glenoid inclination and rotator cuff tears.
Chalmers, Peter N; Beck, Lindsay; Granger, Erin; Henninger, Heath; Tashjian, Robert Z
2018-03-23
The objectives of this study were to determine whether glenoid inclination (1) could be measured accurately on magnetic resonance imaging (MRI) using computed tomography (CT) as a gold standard, (2) could be measured reliably on MRI, and (3) whether it differed between patients with rotator cuff tears and age-matched controls without evidence of rotator cuff tears or glenohumeral osteoarthritis. In this comparative retrospective radiographic study, we measured glenoid inclination on T1 coronal MRI corrected into the plane of the scapula. We determined accuracy by comparison with CT and inter-rater reliability. We compared glenoid inclination between patients with full-thickness rotator cuff tears and patients aged >50 years without evidence of a rotator cuff tear or glenohumeral arthritis. An a priori power analysis determined adequate power to detect a 2° difference in glenoid inclination. (1) In a validation cohort of 37 patients with MRI and CT, the intraclass correlation coefficient was 0.877, with a mean difference of 0° (95% confidence interval, -1° to 1°). (2) For MRI inclination, the inter-rater intraclass correlation coefficient was 0.911. (3) Superior glenoid inclination was 2° higher (range, 1°-4°, P < .001) in the rotator cuff tear group of 192 patients than in the control cohort of 107 patients. Glenoid inclination can be accurately and reliably measured on MRI. Although superior glenoid inclination is statistically greater in those with rotator cuff tears than in patients of similar age without rotator cuff tears or glenohumeral arthritis, the difference is likely below clinical significance. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
McNamara, William J; Lam, Patrick H; Murrell, George A C
2016-11-16
Retear and stiffness are not uncommon outcomes of rotator cuff repair. The purpose of this study was to evaluate the relationship between rotator cuff repair healing and shoulder stiffness. A total of 1,533 consecutive shoulders had an arthroscopic rotator cuff repair by a single surgeon. Patients assessed their shoulder stiffness using a Likert scale preoperatively and at 1, 6, 12, and 24 weeks (6 months) postoperatively, and examiners evaluated passive range of motion preoperatively and at 6, 12, and 24 weeks postoperatively. Repair integrity was determined by ultrasound evaluation at 6 months. After rotator cuff repair, there was an overall significant loss of patient-ranked and examiner-assessed shoulder motion at 6 weeks compared with preoperative measurements (p < 0.0001), a partial recovery at 12 weeks, and a full recovery at 24 weeks. Shoulders that were stiff before surgery were more likely to be stiff at 6, 12, and, to a lesser extent, 24 weeks after surgery (r = 0.10 to 0.31; p < 0.0001). A stiffer shoulder at 6 and 12 weeks (but not 24 weeks) postoperatively correlated with better rotator cuff integrity at 6 months postoperatively (r = 0.11 to 0.18; p < 0.001). The retear rate of patients with ≤20° of external rotation at 6 weeks postoperatively was 7%, while the retear rate of patients with >20° of external rotation at 6 weeks was 15% (p < 0.001). In patients who developed stiffness after surgery, a rotator cuff repair was more likely to heal. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Zhang, Zhenxiang; Gu, Beibei; Zhu, Wei; Zhu, Lixian; Li, Qingsong
2014-08-01
This prospective, randomized study was performed to evaluate the results of mini-open and arthroscopic rotator cuff repair in a comparative case series of patients followed for 24 months. A total of 125 patients were randomized to mini-open (Group I) or arthroscopic (Group II) rotator cuff repair at the time of surgical intervention. The University of California Los Angeles (UCLA) score, the American Shoulder and Elbow Surgeons (ASES) index, and muscle strength were measured to evaluate the clinical results, while magnetic resonance arthrography was used at 24-month follow-up to investigate the postoperative rotator cuff integrity. Fifty-three patients in Group I and 55 patients in Group II were available for evaluation at 24-month follow-up. At 24-month follow-up, the UCLA score, the ASES index, and muscle strength were statistically significantly increased in both groups postoperatively, while no significant difference was detected between the 2 groups. Intact rotator cuffs were investigated in 42 patients in Group I and 35 in Group II, and there was a significant difference in postoperative structural integrity between the two groups (P < 0.05). When analysis was limited to the patients with full-thickness tear, the muscle strength of the shoulder was significantly better in Group II, and the retearing rate was significantly higher in Group II. Based on the results obtained from this study, it can be indicated that arthroscopic and mini-open rotator cuff repair displayed substantially equal outcomes, except for higher retearing rate in the arthroscopic repair group. While for patients with full-thickness tear, arthroscopic rotator cuff repair displayed better shoulder strength and significantly higher retearing rate as compared to mini-open rotator cuff repair at 24-month follow-up.
Radiographic progression of arthritic changes in shoulders with degenerative rotator cuff tears.
Chalmers, Peter N; Salazar, Dane H; Steger-May, Karen; Chamberlain, Aaron M; Stobbs-Cucchi, Georgia; Yamaguchi, Ken; Keener, Jay D
2016-11-01
Very little longitudinal information has been available regarding the relationship of cuff tears and arthritis. The purpose of this study was to determine the midterm risk of and risk factors for rotator cuff tear arthropathy progression in a cohort of subjects with an asymptomatic rotator cuff tear. Baseline (visit 1), 5-year (visit 2), and most recent follow-up (visit 3) radiographs were reviewed in a cohort of 105 subjects enrolled for longitudinal surveillance of asymptomatic degenerative rotator cuff tears and 33 controls. The radiographs were assessed in a blinded, randomized fashion by 3 observers who graded glenohumeral arthritic changes using the Hamada scores, Samilson-Prieto (SPO) scores, and acromiohumeral interval (AHI). Osteoarthritis (SPO classification), cuff tear arthropathy (Hamada classification), and AHI progressed between visits 1 and 3 (median, 8 years; P < .001 in all cases). SPO progression was not significantly different for partial- vs. full-thickness vs. control baseline tear types (P = .19). Both full-thickness and partial-thickness tears had greater progression in Hamada scores than controls did in the first 5 years of follow-up (P = .02 and P = .03, respectively), but scores did not differ between partial- and full-thickness tears. Tears with and without enlargement did not differ in progression in SPO grade, Hamada grade, or AHI. Glenohumeral arthritic changes progress significantly but remain minimal within an 8-year period in early to moderate degenerative cuff disease. Whereas the presence of a rotator cuff tear influences progression in Hamada grade, the magnitude of radiographic progression is not influenced by tear severity or enlargement at midterm time points. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Terabayashi, Nobuo; Watanabe, Tsuneo; Matsumoto, Kazu; Takigami, Iori; Ito, Yoshiki; Fukuta, Masashi; Akiyama, Haruhiko; Shimizu, Katsuji
2014-09-01
Night pain is a particularly vexing symptom in patients with rotator cuff tear. It disturbs sleep and decreases quality of life, and there is no consensus regarding its etiology. Based on arthroscopic surgical observations of synovitis around the rotator interval or capsule surface in rotator cuff tear, we hypothesized that blood flow from the artery feeding the capsule increases blood supply to the synovium. This study aimed to investigate the relationship between blood flow and night pain using pulse Doppler ultrasonography. A series of 47 consecutive patients with rotator cuff tear was evaluated. The peak systolic velocity and resistance index of blood flow in the ascending branch of the anterior humeral circumflex artery were evaluated using pulse Doppler ultrasonography. We also investigated 20 normal shoulders in healthy volunteers. The peak systolic velocity and resistance index were compared between affected and unaffected sides in patients and between dominant and nondominant sides in controls. Anterior humeral circumflex artery peak systolic velocity and resistance index did not differ between sides in control subjects or in patients with rotator cuff tear without night pain. However, anterior humeral circumflex artery peak systolic velocity and resistance index did differ significantly between sides in patients with rotator cuff tear with night pain. This study revealed anterior humeral circumflex artery hemodynamics in patients with rotator cuff tear and normal subjects using Doppler ultrasonography. Night pain, particularly involving aching, appears to be related to the hemodynamics. These findings suggest that investigating the hemodynamics of patients with rotator cuff tear with night pain may lead to greater understanding of the etiology of this symptom.
Street, Matthew; Thambyah, Ashvin; Dray, Michael; Amirapu, Satya; Tuari, Donna; Callon, Karen E; McIntosh, Julie D; Burkert, Kristina; Dunbar, P Rod; Coleman, Brendan; Cornish, Jillian; Musson, David S
2015-10-20
Rotator cuff tears can cause significant pain and functional impairment. Without surgical repair, the rotator cuff has little healing potential, and following surgical repair, they are highly prone to re-rupture. Augmenting such repairs with a biomaterial scaffold has been suggested as a potential solution. Extracellular matrix (ECM)-based scaffolds are the most commonly used rotator cuff augments, although to date, reports on their success are variable. Here, we utilize pre-clinical in vitro and in vivo assays to assess the efficacy of a novel biomaterial scaffold, ovine forestomach extracellular matrix (OFM), in augmenting rotator cuff repair. OFM was assessed in vitro for primary tenocyte growth and adherence, and for immunogenicity using an assay of primary human dendritic cell activation. In vivo, using a murine model, supraspinatus tendon repairs were carried out in 34 animals. Augmentation with OFM was compared to sham surgery and unaugmented control. At 6- and 12-week time points, the repairs were analysed biomechanically for strength of repair and histologically for quality of healing. OFM supported tenocyte growth in vitro and did not cause an immunogenic response. Augmentation with OFM improved the quality of healing of the repaired tendon, with no evidence of excessive inflammatory response. However, there was no biomechanical advantage of augmentation. The ideal rotator cuff tendon augment has not yet been identified or clinically implemented. ECM scaffolds offer a promising solution to a difficult clinical problem. Here, we have shown improved histological healing with OFM augmentation. Identifying materials that offset the poorer mechanical properties of the rotator cuff post-injury/repair and enhance organised tendon healing will be paramount to incorporating augmentation into surgical treatment of the rotator cuff.
Increasing age and tear size reduce rotator cuff repair healing rate at 1 year
Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J
2017-01-01
Background and purpose — There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods — Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results — The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation — Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor. PMID:28880113
Gwak, Heui-Chul; Kim, Chang-Wan; Kim, Jung-Han; Choo, Hye-Jeung; Sagong, Seung-Yeob; Shin, John
2015-05-01
The purpose of this study was to evaluate the extension of delamination and the cuff integrity after arthroscopic repair of delaminated rotator cuff tears. Sixty-five patients with delaminated rotator cuff tears were retrospectively reviewed. The delaminated tears were divided into full-thickness delaminated tears and partial-thickness delaminated tears. To evaluate the medial extension, we calculated the coronal size of the delaminated portion. To evaluate the posterior extension, we checked the tendon involved. Cuff integrity was evaluated by computed tomography arthrography. The mean medial extension in the full-thickness and partial-thickness delaminated tears was 18.1 ± 6.0 mm and 22.7 ± 6.3 mm, respectively (P = .0084). The posterior extension into the supraspinatus and the infraspinatus was 36.9% and 32.3%, respectively, in the full-thickness delaminated tears, and it was 27.7% and 3.1%, respectively, in the partial-thickness delaminated tears (P = .0043). With regard to cuff integrity, 35 cases of anatomic healing, 10 cases of partial healing defects, and 17 cases of retear were detected. Among the patients with retear and partial healing of the defect, all the partially healed defects showed delamination. Three retear patients showed delamination, and 14 retear patients did not show delamination; the difference was statistically significant (P = .0001). The full-thickness delaminated tears showed less medial extension and more posterior extension than the partial-thickness delaminated tears. Delamination did not develop in retear patients, but delamination was common in the patients with partially healed defects. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Jiang, Nancy; Del Signore, Anthony G; Iloreta, Alfred M; Malkin, Benjamin D
2013-08-01
The purpose of this study was to evaluate the efficacy of a novel teaching tool to improve health care providers' ability to inflate tracheostomy tube cuffs to the appropriate pressure. Single-blinded, randomized, controlled trial. Subjects were randomized to a control and study group. The control group viewed a video about inflating tracheostomy tube cuffs to safe pressure levels. The study group viewed the same video and also got to palpate the pilot balloons of tracheostomy tube cuffs inflated to three different pressures. All subjects inflated tracheostomy tube cuffs to pressures they believed to be appropriate based on palpation of the pilot balloon preintervention, and immediately, 2 weeks, and 3 months postintervention. Forty-nine health care providers participated in the study. There was no significant difference in the mean preintervention cuff inflation pressures between the two groups (36 cm H2 O vs. 38 cm H2 O, P = 0.4888), with both initially overinflating. Postintervention, the study group inflated the cuffs to significantly lower pressures than the control group, closer to the ideal of 25 cm H2 O (26 cm H2 O vs. 35 cm H2 O, P = 0.0001). This difference was also observed 2 weeks (28 cm H2 O vs. 37 cm H2 O P <0.0001) and 3 months (28 cm H2 O vs. 36 cm H2 O, P = 0.0002) postintervention. The novel teaching tool evaluated in this study is simple, easily reproducible, and low-cost. Its use leads to long-lasting improvement in health care providers' ability to more accurately inflate tracheostomy tube cuffs to safe pressures. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Mook, William R; Greenspoon, Joshua A; Millett, Peter J
2016-01-01
Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. The preferred technique for rotator cuff repair of the senior author was reviewed and described in a step by step fashion. The final construct is a knotless double row transosseous equivalent construct. The described technique includes the advantages of a double-row construct while also offering self reinforcement, decreased risk of suture cut through, decreased risk of medial row overtensioning and tissue strangulation, improved vascularity, the efficiency of a knotless system, and no increased risk for subacromial impingement from the burden of suture knots. Arthroscopic knotless double row rotator cuff repair is a safe and effective method to repair rotator cuff tears.
Mook, William R.; Greenspoon, Joshua A.; Millett, Peter J.
2016-01-01
Background: Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. Methods: The preferred technique for rotator cuff repair of the senior author was reviewed and described in a step by step fashion. The final construct is a knotless double row transosseous equivalent construct. Results: The described technique includes the advantages of a double-row construct while also offering self reinforcement, decreased risk of suture cut through, decreased risk of medial row overtensioning and tissue strangulation, improved vascularity, the efficiency of a knotless system, and no increased risk for subacromial impingement from the burden of suture knots. Conclusion: Arthroscopic knotless double row rotator cuff repair is a safe and effective method to repair rotator cuff tears. PMID:27733881
Ji, Jong-Hun; Shafi, Mohamed; Moon, Chang-Yun; Park, Sang-Eun; Kim, Yeon-Jun; Kim, Sung-Eun
2013-11-01
Arthroscopic removal, now the main treatment option, has almost replaced open surgery for treatment of resistant calcific tendinitis. In some cases of chronic calcific tendinitis of the shoulder, the calcific materials are hard and adherent to the tendon. Removal of these materials can cause significant intratendinous tears between the superficial and deep layers of the degenerated rotator cuff. Thus far, there are no established surgical techniques for removing the calcific materials while ensuring cuff integrity. Good clinical results for rotator cuff repair were achieved by using an arthroscopic suture bridge technique in patients with long-standing calcific tendinitis. Intact rotator cuff integrity and recovery of signal change on follow-up magnetic resonance imaging scans were confirmed. This is a technical note about a surgical technique and its clinical results with a review of relevant published reports. © 2013 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.
Fennerty, M; Corless, C; Sheppard, B; Faigel, D; Lieberman, D; Sampliner, R
2001-01-01
The previous paradigm that Barrett's is an irreversible premalignant lesion has recently been challenged by a proliferation of reports documenting elimination of Barrett's by a variety of endoscopic techniques. Whether Barrett's is entirely eliminated is unknown as endoscopic biopsy samples the surface of the epithelium only. Numerous reports document underlying specialised columnar epithelium in many of these trials. Until now there have been no reports of pathological examination of the entire oesophagus as a specimen. This case documents complete elimination of intestinal metaplasia from the oesophagus and supports the biological plausibility of these research techniques. Keywords: Barrett's oesophagus; endoscopy; multipolar electrocoagulation PMID:11413122
Huang, Ling; Xie, Chen; Zhang, Lifeng; Meng, Liying; Li, Guizheng; Li, Yang; Huang, Bing; Pan, Linghui; Tang, Zhanhong
2017-01-01
To discuss the influence of intermittently monitoring on endotracheal tube cuff pressure using handheld pressure gauge, and to provide some reference for the clinical work. The experiment was carried out on the model of the glass tube, which was divided into three parts. Each part of the experiment was divided into normal pressure group and high pressure group according to the different inflation pressure target value. The endotracheal tube cuff pressure was determined intermittently by using the transparent tracheal models which had a static diameter of 2 cm. The target press value of normal pressure group was 32 cmH 2 O (1 cmH 2 O = 0.098 kPa) while that of high pressure group was 40 cmH 2 O. The handheld pressure gauge was connected with the indicated cuff through a tee joint, and the pressure in the cuff in both groups was determined. The pressure loss caused by intermittent measurement of the two groups was compared. By switching the tee joint, the pressure loss through the gauge self-structure and the pressure loss when connecting and disconnecting the indicated cuff were determined to analyze the causes of pressure loss caused by intermittent measurement of pressure gauge. The pressure loss caused by intermittent measurement of high pressure group was significantly higher than that of normal pressure group (cmH 2 O: 15.10±0.43 vs. 10.19±0.45) with statistical significance (t = -24.875, P = 0.000). The pressure loss through the gauge self-structure of high pressure group was also significantly higher than that of normal pressure group (cmH 2 O: 13.91±0.48 vs. 8.77±0.53), which showed a statistics significance (t = -22.854, P = 0.000). The pressure loss when connecting and disconnecting the indicated cuff of the normal pressure and high pressure groups were (1.33±0.49) cmH 2 O and (1.23±0.55) cmH 2 O, respectively, without statistics significance (t = 0.445, P = 0.662). It was figured that the total pressure loss caused by intermittent measurement of the endotracheal intubation cuff was approximately equal to the value of the pressure loss caused by the pressure gauge self-structure and the pressure loss when the indicated cuff was connected and disconnected [normal pressure group: (10.19±0.45) cmH 2 O ≍ (8.77±0.53) cmH 2 O + (1.33±0.49) cmH 2 O, high pressure group: (15.10±0.43) cmH 2 O ≍ (13.91±0.48) cmH 2 O + (1.23±0.55) cmH 2 O]. The intermittently monitoring on endotracheal tube cuff pressure is the main cause of the pressure loss. The total pressure loss consists of the pressure leak from the cuff to the gauge and the pressure leak when connecting and disconnecting the gauge and the indicated cuff during each test. When the pressure in the cuff is increased, it will cause more pressure loss.
Polarization-direction correlation measurement --- Experimental test of the PDCO methods
NASA Astrophysics Data System (ADS)
Starosta, K.; Morek, T.; Droste, Ch.; Rohoziński, S. G.; Srebrny, J.; Bergstrem, M.; Herskind, B.
1998-04-01
Information about spins and parities of excited states is crucial for nuclear structure studies. In ``in-beam" gamma ray spectroscopy the directional correlation (DCO) or angular distribution measurements are widely used tools for multipolarity assignment; although, it is known that neither of these methods is sensitive to electric or magnetic character of gamma radiation. Multipolarity of gamma rays may be determined when the results of the DCO analysis are combined with the results of linear polarization measurements. The large total efficiency of modern multidetector arrays allows one to carry out coincidence measurements between the polarimeter and the remaining detectors. The aim of the present study was to test experimentally the possibility of polarization-direction correlation measurements using the EUROGAM II array. The studied nucleus was ^164Yb produced in the ^138Ba(^30Si,4n) reaction at beam energies of 150 and 155 MeV. The angular correlation, linear polarization and direction-polarization correlation were measured for the strong transitions in yrast and non yrast cascades. Application of the PDCO analysis to a transition connecting a side band with the yrast band allowed one to rule out most of the ambiguities in multipolarity assignment occuring if one used angular correlations only.
Time-Lapse Cinemicrographic Studies of X-Irradiated HeLa S3 Cells
Hurwitz, Camilla; Tolmach, L. J.
1969-01-01
Analysis of time-lapse cinemicrographs of X-irradiated HeLa S3 cells has shown that the incidence of cell fusion was increased from 0.9% (following 1267 divisions) in control cells to an average of 22% (following 655 divisions) in cells irradiated with 500 rad doses of 220 kv X-rays. The incidence depended on the stage of the generation cycle at which the parent cells were irradiated. It was nearly constant in the first three postirradiation generations. Fusion occurred at all stages of the generation cycle, but preferentially during the first 20%. Cells undergoing fusion progressed more slowly through the generation cycle and had a higher probability of disintegrating than did irradiated cells that did not fuse. The occurrence of fusion was clonally distributed in the population. It took place only between sister (or closely related) cells. Protoplasmic bridges were often visible between sister cells prior to fusion. Giant cells arose only as a result of fusion. The incidence of multipolar divisions, though higher than in unirradiated cells, was only 5.5% in cultures irradiated with 500 rads. Fusion occurred following 85% of the multipolar divisions and was often followed by a multipolar division. ImagesFigure 1 PMID:5807221
El-Tawil, Sherif; Prinja, Aditya; Stanton, Jeremy
2015-01-01
We describe the first reported case of a tumour deposit within the rotator cuff presenting as a bizarre, progressive, and fixed external rotation deformity of the shoulder. It is also the first reported case to our knowledge of an oesophageal primary metastasising to the rotator cuff. PMID:26543658
[Continuous inflation of a leaking cuff of an intubation tube].
Boussard, N; Helmer, J; Rose, E; Lascombes, P
1988-01-01
Perforation of the cuff of the endotracheal tube peroperatively is a very serious problem, especially when it occurs in a patient prone on an orthopaedic table. This is even more dramatic when the patient is not breathing spontaneously and he cannot be turned over to be reintubated. Given the unusual character of this situation, an apparatus has been designed to keep the cuff inflated permanently. It was a circuit consisting of a manual pressure valve, flexible tubing, a peripheral catheter and the cuff supply tube. The gas used was medical air at 3 bar pressure. This method proved perfectly safe and efficient, the operation having continued without reintubation.
Shoulder disorders in an outpatient clinic: an epidemiological study.
Malavolta, Eduardo Angeli; Gracitelli, Mauro Emilio Conforto; Assunção, Jorge Henrique; Pinto, Gustavo de Mello Ribeiro; da Silveira, Arthur Zorzi Freire; Ferreira, Arnaldo Amado
2017-01-01
To describe shoulder disorders in patients evaluated by two shoulder and elbow surgeons. This cross-sectional study analyzed patients evaluated by two authors, excluding acute fractures and dislocations and patients with symptoms not involving the shoulder. Age and sex distribution was determined for the different diagnoses. We evaluated 1001 patients. Mean age was 51.43±15.15 years and 51.0% were female. Disorders of the rotator cuff occurred in 64.3% (41.2% tendinopathy, 11.0% partial tears and 12.2% full-thickness tears). Adhesive capsulitis occurred in 13.5% of cases and glenohumeral instability in 8.1%. Rotator cuff disorders were more common in women, with a peak between 50 and 59 years for tendinopathy and partial tears and between 60 and 69 years for full-thickness tears. Glenohumeral instability was more frequent in men, with a peak between 30 and 39 years. The most frequent diagnosis was rotator cuff tendinopathy, followed by adhesive capsulitis, full-thickness rotator cuff tears, partial rotator cuff tears and glenohumeral instability. Rotator cuff lesions were more common in women, with a peak between 60 and 69 years for full-thickness tears. Level of Evidence IV, Case Series.
Krieger, J R; Tellier, L E; Ollukaren, M T; Temenoff, J S; Botchwey, E A
2017-06-01
Rotator cuff tears cause muscle degeneration that is characterized by myofiber atrophy, fatty infiltration, and fibrosis and is minimally responsive to current treatment options. The underlying pathogenesis of rotator cuff muscle degeneration remains to be elucidated, and increasing evidence implicates immune cell infiltration as a significant factor. Because immune cells are comprised of highly heterogeneous subpopulations that exert divergent effects on injured tissue, understanding trafficking and accumulation of immune subpopulations may hold the key to more effective therapies. The present study quantifies subpopulations of immune cells infiltrating the murine supraspinatus muscle after severe rotator cuff injury that includes tenotomy and denervation. Rotator cuff injury stimulates dramatic infiltration of mononuclear phagocytes, enriches mononuclear phagocytes in non-classical subpopulations, and enriches T lymphocytes in T H and T reg subpopulations. The combination of tenotomy plus denervation significantly increases mononuclear phagocyte infiltration, enriches macrophages in the non-classical subpopulation, and decreases T lymphocyte enrichment in T H cells compared to tenotomy alone. Depletion of circulating monocytes via liposomal clodronate accelerates supraspinatus atrophy after tenotomy and denervation. The study may aid rational design of immunologically smart therapies that harness immune cells to enhance outcomes after rotator cuff tears.
Arthroscopic treatment options for irreparable rotator cuff tears of the shoulder
Anley, Cameron M; Chan, Samuel KL; Snow, Martyn
2014-01-01
The management of patients with irreparable rotator cuff tears remains a challenge for orthopaedic surgeons with the final treatment option in many algorithms being either a reverse shoulder arthroplasty or a tendon transfer. The long term results of these procedures are however still widely debated, especially in younger patients. A variety of arthroscopic treatment options have been proposed for patients with an irreparable rotator cuff tear without the presence of arthritis of the glenohumeral joint. These include a simple debridement with or without a biceps tenotomy, partial rotator cuff repair with or without an interval slide, tuberplasty, graft interposition of the rotator cuff, suprascapular nerve ablation, superior capsule reconstruction and insertion of a biodegradable spacer (Inspace) to depress the humeral head. These options should be considered as part of the treatment algorithm in patients with an irreparable rotator cuff and could be used as either as an interim procedure, delaying the need for more invasive surgery in the physiologically young and active, or as potential definitive procedures in the medically unfit. The aim of this review is to highlight and summarise arthroscopic procedures and the results thereof currently utilised in the management of these challenging patients. PMID:25405083
An epidemiological study of rotator cuff pathology using The Health Improvement Network database.
White, J J E; Titchener, A G; Fakis, A; Tambe, A A; Hubbard, R B; Clark, D I
2014-03-01
Little is known about the incidence of rotator cuff pathology or its demographic associations in the general population. We undertook a large epidemiological study of rotator cuff pathology in the United Kingdom using The Health Improvement Network (THIN) database. The incidence of rotator cuff pathology was 87 per 100,000 person-years. It was more common in women than in men (90 cases per 100,000 person-years in women and 83 per 100,000 person-years in men; p < 0.001). The highest incidence of 198 per 100,000 person-years was found in those aged between 55 and 59 years. The regional distribution of incidence demonstrated an even spread across 13 UK health authorities except Wales, where the incidence was significantly higher (122 per 100,000 person-years; p < 0.001). The lowest socioeconomic group had the highest incidence (98 per 100,000 person-years). The incidence has risen fourfold since 1987 and as of 2006 shows no signs of plateauing. This study represents the largest general population study of rotator cuff pathology reported to date. The results obtained provide an enhanced appreciation of the epidemiology of rotator cuff pathology and may help to direct future upper limb orthopaedic services.
Endotracheal tubes and fluid aspiration: an in vitro evaluation of new cuff technologies.
Mariyaselvam, Maryanne Z; Marsh, Lucy L; Bamford, Sarah; Smith, Ann; Wise, Matt P; Williams, David W
2017-03-04
Aspiration of subglottic secretions past the endotracheal tube (ETT) cuff is a prerequisite for developing ventilator-associated pneumonia (VAP). Subglottic secretion drainage (SSD) ETTs reduce aspiration of subglottic secretions and have demonstrated lower VAP rates. We compared the performance of seven SSD ETTs against a non-SSD ETT in preventing aspiration below inflated cuffs. ETTs were positioned vertically in 2 cm diameter cylinders. Four ml of a standard microbial suspension was added above inflated cuffs. After 1 h, aspiration was measured and ETTs demonstrating no leakage were subjected to rotational movement and evaluation over 24 h. Collected aspirated fluid was used to inoculate agar media and incubated aerobically at 37 °C for 24 h. The aspiration rate, volume and number of microorganisms that leaked past the cuff was measured. Experiments were repeated (×10) for each type of ETT, with new ETTs used for each repeat. Best performing ETTs were then tested in five different cylinder diameters (1.6, 1.8, 2.0, 2.2 and 2.4 cm). Experiments were repeated as above using sterile water. Volume and time taken for aspiration past the cuff was measured. Experiments were repeated (×10) for each type of ETT. Results were analysed using non-parametric tests for repeated measures. The PneuX ETT prevented aspiration past the cuff in all experiments. All other ETTs allowed aspiration, with considerable variability in performance. The PneuX ETT was statistically superior in reducing aspiration compared to the SealGuard (p < 0.009), KimVent (p < 0.002), TaperGuard (p < 0.004), Lanz (p < 0.001), ISIS (p < 0.001), SACETT (p < 0.001) and Soft Seal (p < 0.001) ETTs. Of the 4 ETTs tested in differing cylinder sizes, the PneuX significantly reduced aspiration across the range of diameters compared to the SealGuard (p < 0.0001), TaperGuard (p < 0.0001) and KimVent (p < 0.0001) ETTs. ETTs showed substantial variation in fluid aspiration, relating to cuff material and design. Variability in performance was likely due to the random manner in which involutional folds form in the inflated ETT cuff. The PneuX ETT was the only ETT able to consistently prevent aspiration past the cuff in all experiments.
Rotator cuff crepitus: could Codman really feel a cuff tear?
Ponce, Brent A; Kundukulam, Joseph A; Sheppard, Evan D; Determann, Jason R; McGwin, Gerald; Narducci, Carl A; Crowther, Marshall J
2014-07-01
The objective of this study was to assess the accuracy of palpating crepitus to diagnose rotator cuff tears. Seventy consecutive consenting patients who presented with shoulder pain and no previous imaging or surgery on the affected shoulder were prospectively enrolled during a 10-month period. A standardized patient history and examination, including the crepitus test, were recorded in addition to obtaining standard radiographs. Additional imaging after initial evaluation was performed with magnetic resonance imaging and interpreted by a musculoskeletal radiologist blinded to the examination findings. Statistical analysis was used to determine sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the crepitus test in the clinical diagnosis of a rotator cuff tear. Sixty-three patients had histories, examinations, and imaging studies available for analysis. The crepitus test had a sensitivity of 67%, specificity of 80%, PPV of 91%, and NPV of 43% for all types of rotator cuff tears. The sensitivity and specificity for full-thickness or high-grade partial tears was 82% and 73%, respectively; the PPV and NPV were 77% and 79%. Increasing age improved accuracy as the presence of crepitus in patients older than 55 years had a sensitivity of 76%, specificity of 100%, PPV of 100%, and NPV of 38%. The crepitus test has a favorable sensitivity, specificity, PPV, and NPV to assess the integrity of the rotator cuff and may be a useful examination in the clinical diagnosis of a rotator cuff tear. Published by Mosby, Inc.
Internal impingement in the etiology of rotator cuff tendinosis revisited.
Budoff, Jeffrey E; Nirschl, Robert P; Ilahi, Omer A; Rodin, Dennis M
2003-10-01
The theory of internal impingement holds that, in overhead athletes, repeated contact between the undersurface of the rotator cuff and the posterosuperior glenoid rim leads to articular-sided partial-thickness rotator cuff tears and superior labral lesions. However, we have noted this same constellation of lesions in our general patient population. These recreational athletic patients do not routinely assume the position of extreme abduction and external rotation, and thus are unlikely to experience significant internal impingement forces. The goal of this study was to document the prevalence of superior labral lesions in patients being treated for partial-thickness undersurface rotator cuff tears. Retrospective case series. We retrospectively reviewed the records of 75 shoulders arthroscopically treated for partial-thickness articular-sided rotator cuff tears. With the exception of one professional tennis player, no patients were playing sports at a professional or major college level. No professional or collegiate throwing athletes were included. The prevalence of these lesions and their association with recreational athletics was noted. We found that 55 of 75 (73.3%) shoulders with articular-sided partial-thickness rotator cuff tears also had superior labral lesions. A statistically significant increased prevalence of superior labral lesions in the dominant shoulder was seen (P =.03). In addition, our patients who engaged in overhand throwing had significantly fewer superior labral lesions in the dominant shoulders than did nonthrowers (P =.017). The "kissing lesions" of undersurface rotator cuff tears and posterosuperior labral damage may be explained by mechanisms other than "internal impingement."
[A novel technique for distal ureterectomy and bladder cuff excision].
Sotelo, R; Ramírez, D; Carmona, O; di Grazia, E; de Andrade, R; Giedelman, C; Pascal, Z; Gill, I; Desai, M
2011-03-01
We describe a novel endoscopic approach and provide a literature review for the "en bloc" dissection of the distal ureter and bladder cuff during laparoscopic radical nephroureterectomy using a transvesical single port approach under pneumovesicum. The procedure was performed in an 80-year old male with a history of gross hematuria due to left renal pelvic TCC and no history of prior bladder TCC. Laparoscopic radical nephroureterectomy was performed and the ureter was dissected down to the bladder and clipped. A single-port device was inserted transvesically and pneumovesicum established. A full thickness incision of the bladder around the ureter was performed with progressive intravesical mobilization of the distal ureter. Subsequently, a water-tight closure of the bladder defect was achieved. The distal ureter, together with the bladder cuff, was then delivered en bloc laparoscopically with the specimen. The operating time (LESS radical nephroureterectomy, RPLND, and bladder cuff excision) was 6hours and 15minutes. The bladder cuff time was 45minutes. There were no intra or postoperative complications and the catheter was removed after 6 days. Histopathological analysis showed kidney-invasive papillary urothelial cancer, pT3 pN0 (0/7) G3. The distal ureter and bladder cuff techniques have not yet been standardized. Management of the bladder cuff with a single port is feasible. Additional studies are needed to identify the best approach for management of the distal ureter at the time of laparoscopic nephroureterectomy. Copyright © 2010 AEU. Published by Elsevier Espana. All rights reserved.
Perivascular fluid cuffs decrease lung compliance by increasing tissue resistance.
Lowe, Kevin; Alvarez, Diego F; King, Judy A; Stevens, Troy
2010-06-01
Lung inflammation causes perivascular fluid cuffs to form around extra-alveolar blood vessels; however, the physiologic consequences of such cuffs remain poorly understood. Herein, we tested the hypothesis that perivascular fluid cuffs, without concomitant alveolar edema, are sufficient to decrease lung compliance. Prospective, randomized, controlled study. Research laboratory. One hundred twenty male CD40 rats. To test this hypothesis, the plant alkaloid thapsigargin was used to activate store-operated calcium entry and increase cytosolic calcium in endothelium. Thapsigargin was infused into a central venous catheter of intact, sedated, and mechanically ventilated rats. Static and dynamic lung mechanics and hemodynamics were measured continuously. Thapsigargin produced perivascular fluid cuffs along extra-alveolar vessels but did not cause alveolar flooding or blood gas abnormalities. Lung compliance dose-dependently decreased after thapsigargin infusion, attributable to an increase in tissue resistance that was attributed to increased tissue damping and tissue elastance. Airway resistance was not changed. Neither central venous pressure nor left ventricular end diastolic pressure was altered by thapsigargin. Heart rate did not change, although thapsigargin decreased left ventricular systolic function sufficient to reduce cardiac output by 50%. Infusion of the type 4 phosphodiesterase inhibitor, rolipram, prevented thapsigargin from inducing perivascular cuffs and decreasing lung compliance. Rolipram also normalized pressure over time and corrected the deficit in cardiac output. Our findings resolve for the first time that perivascular cuff formation negatively impacts mechanical coupling between the bronchovascular bundle and the lung parenchyma, decreasing lung compliance without impacting central venous pressure.
Establishing Maximal Medical Improvement After Arthroscopic Rotator Cuff Repair.
Zuke, William A; Leroux, Timothy S; Gregory, Bonnie P; Black, Austin; Forsythe, Brian; Romeo, Anthony A; Verma, Nikhil N
2018-03-01
As health care transitions from a pay-for-service to a pay-for-performance infrastructure, the value of orthopaedic care must be defined accurately. Significant efforts have been made in defining quality and cost in arthroplasty; however, there remains a lag in ambulatory orthopaedic care. Two-year follow-up has been a general requirement for reporting outcomes after rotator cuff repair. However, this time requirement has not been established scientifically and is of increasing importance in the era of value-based health care. Given that arthroscopic rotator cuff repair is a common ambulatory orthopaedic procedure, the purpose of this study was to establish a time frame for maximal medical improvement (the state when improvement has stabilized) after arthroscopic rotator cuff repair. Systematic review. A systematic review of the literature was conducted, identifying studies reporting sequential patient-reported outcomes up to a minimum of 2 years after arthroscopic rotator cuff repair. The primary clinical outcome was patient-reported outcomes at 3-month, 6-month, 1-year, and 2-year follow-up. Secondary clinical outcomes included range of motion, strength, retears, and complications. Clinically significant improvement was determined between various time intervals by use of the minimal clinically important difference. The review included 19 studies including 1370 patients who underwent rotator cuff repair. Clinically significant improvement in patient-reported outcomes was seen up to 1 year after rotator cuff repair, but no clinical significance was noted from 1 year to 2 years. The majority of improvement in strength and range of motion was seen up to 6 months, but no clinically meaningful improvement was seen thereafter. All reported complications and the majority of retears occurred within 6 months after rotator cuff repair. After rotator cuff repair, a clinically significant improvement in patient-reported outcomes, range of motion, and strength was seen up to 1 year after surgery, but not beyond this. This information is important not only to establish appropriate patient expectations but also to determine a time frame for outcome collection after surgery to better define value in orthopaedic care.
Lambers Heerspink, Frederik O; Hoogeslag, Roy Ag; Diercks, Ron L; van Eerden, Pepijn Jm; van den Akker-Scheek, Inge; van Raay, Jos Jam
2011-01-26
Subacromial impingement syndrome is a frequently observed disorder in orthopedic practice. Lasting symptoms and impairment may occur when a subsequent atraumatic rotator cuff rupture is also present. However, degenerative ruptures of the rotator cuff can also be observed in asymptomatic elderly individuals. Treatment of these symptomatic degenerative ruptures may be conservative or surgical. Acceptable results are reported for both treatment modalities. No evidence-based level-1 studies have been conducted so far to compare these treatment modalities. The objective of this study is to determine whether there is a difference in outcome between surgical reconstruction and conservative treatment of a degenerative atraumatic rotator cuff tendon rupture. A randomized controlled trial will be conducted. Patients aged between 45 and 75 with a symptomatic atraumatic rotator cuff rupture as diagnosed by MRI will be included. Exclusion criteria are traumatic rotator cuff rupture, frozen shoulder and diabetes mellitus. Patients will be randomized into two groups. Conservative treatment includes physical therapy according to a standardized protocol, NSAIDs and, if indicated, subacromial infiltration with a local anesthetic and corticosteroids. Surgical reconstruction is performed under general anesthesia in combination with an interscalenus plexus block. An acromioplasty with reconstruction of the rotator cuff tendon is performed, as described by Rockwood et al. Measurements take place preoperatively and 6 weeks, 3 months, 6 months and 1 year postoperatively. The primary outcome measure is the Constant score. Secondary measures include both disease-specific and generic outcome measures, and an economic evaluation. Additionally, one year after inclusion a second MRI will be taken of all patients in order to determine whether extent and localization of the rupture as well as the amount of fatty degeneration are prognostic factors. Both surgical as conservative treatment of a symptomatic atraumatic rotator cuff tendon rupture is used in current practice. There is a lack of level-1 studies comparing surgical vs. conservative treatment. This randomized controlled trial has been designed to determine whether the surgical treatment of a degenerative atraumatic rotator cuff tendon rupture may lead to a better functional and radiological outcome than conservative treatment after one year of follow-up. Netherlands Trial Register (NTR): NTRTC2343.
Increased Upper Trapezius Muscle Stiffness in Overhead Athletes with Rotator Cuff Tendinopathy
Leong, Hio Teng; Hug, François; Fu, Siu Ngor
2016-01-01
Although excessive tension of the upper trapezius (UT) is thought to contribute to rotator cuff tendinopathy, no study examined UT tension in athletes with and without rotator cuff tendinopathy. Here we used UT shear modulus measured using ultrasound shear wave elastography as an index of muscle stiffness/tension. The aims of this study were twofold: 1) to determine whether the UT muscle shear modulus is altered in athletes with rotator cuff tendinopathy compared to asymptomatic athletes, and 2) to detect optimal cut-off points of UT shear modulus in identifying athletes with rotator cuff tendinopathy. Forty-three male volleyball players (17 asymptomatic and 26 with rotator cuff tendinopathy, mean age = 22.9±3.5 years) participated in the study. UT shear modulus was quantified during active arm holding at 30° and 60° of shoulder abduction and passive arm positioning at 0°, 30° and 60° of shoulder abduction. During the active tasks, the UT shear modulus was higher in athletes with rotator cuff tendinopathy than the asymptomatic athletes (p = 0.002), regardless the arm position. During the passive tasks, athletes with rotator cuff tendinopathy exhibited a higher UT shear modulus than asymptomatic athletes only at 0° of shoulder abduction (13.0±2.5 kPa vs 10.2±1.8 kPa, p = 0.001). When considering the active task, an optimal cut-off shear modulus of 12.0 kPa at 30° of shoulder abduction (sensitivity = 0.84, specificity = 0.57, AUC = 0.757, p = 0.008) and 9.5 kPa at 60° of shoulder abduction (sensitivity = 0.88, specificity = 0.67, AUC = 0.816, p = 0.002) was detected. When considering the passive task at 0° of shoulder abduction, a cut-off of 12.2 kPa was found (sensitivity = 0.73, AUC = 0.817, p = 0.001). Findings from the present study show that monitoring passive and active UT muscle shear modulus may provide important information for the prevention/rehabilitation of rotator cuff tendinopathy. PMID:27159276
Increased Upper Trapezius Muscle Stiffness in Overhead Athletes with Rotator Cuff Tendinopathy.
Leong, Hio Teng; Hug, François; Fu, Siu Ngor
2016-01-01
Although excessive tension of the upper trapezius (UT) is thought to contribute to rotator cuff tendinopathy, no study examined UT tension in athletes with and without rotator cuff tendinopathy. Here we used UT shear modulus measured using ultrasound shear wave elastography as an index of muscle stiffness/tension. The aims of this study were twofold: 1) to determine whether the UT muscle shear modulus is altered in athletes with rotator cuff tendinopathy compared to asymptomatic athletes, and 2) to detect optimal cut-off points of UT shear modulus in identifying athletes with rotator cuff tendinopathy. Forty-three male volleyball players (17 asymptomatic and 26 with rotator cuff tendinopathy, mean age = 22.9±3.5 years) participated in the study. UT shear modulus was quantified during active arm holding at 30° and 60° of shoulder abduction and passive arm positioning at 0°, 30° and 60° of shoulder abduction. During the active tasks, the UT shear modulus was higher in athletes with rotator cuff tendinopathy than the asymptomatic athletes (p = 0.002), regardless the arm position. During the passive tasks, athletes with rotator cuff tendinopathy exhibited a higher UT shear modulus than asymptomatic athletes only at 0° of shoulder abduction (13.0±2.5 kPa vs 10.2±1.8 kPa, p = 0.001). When considering the active task, an optimal cut-off shear modulus of 12.0 kPa at 30° of shoulder abduction (sensitivity = 0.84, specificity = 0.57, AUC = 0.757, p = 0.008) and 9.5 kPa at 60° of shoulder abduction (sensitivity = 0.88, specificity = 0.67, AUC = 0.816, p = 0.002) was detected. When considering the passive task at 0° of shoulder abduction, a cut-off of 12.2 kPa was found (sensitivity = 0.73, AUC = 0.817, p = 0.001). Findings from the present study show that monitoring passive and active UT muscle shear modulus may provide important information for the prevention/rehabilitation of rotator cuff tendinopathy.
High-resolution measurement of electrically-evoked vagus nerve activity in the anesthetized dog
NASA Astrophysics Data System (ADS)
Yoo, Paul B.; Lubock, Nathan B.; Hincapie, Juan G.; Ruble, Stephen B.; Hamann, Jason J.; Grill, Warren M.
2013-04-01
Objective. Not fully understanding the type of axons activated during vagus nerve stimulation (VNS) is one of several factors that limit the clinical efficacy of VNS therapies. The main goal of this study was to characterize the electrical recruitment of both myelinated and unmyelinated fibers within the cervical vagus nerve. Approach. In anesthetized dogs, recording nerve cuff electrodes were implanted on the vagus nerve following surgical excision of the epineurium. Both the vagal electroneurogram (ENG) and laryngeal muscle activity were recorded in response to stimulation of the right vagus nerve. Main results. Desheathing the nerve significantly increased the signal-to-noise ratio of the ENG by 1.2 to 9.9 dB, depending on the nerve fiber type. Repeated VNS following nerve transection or neuromuscular block (1) enabled the characterization of A-fibers, two sub-types of B-fibers, and unmyelinated C-fibers, (2) confirmed the absence of stimulation-evoked reflex compound nerve action potentials in both the ipsilateral and contralateral vagus nerves, and (3) provided evidence of stimulus spillover into muscle tissue surrounding the stimulating electrode. Significance. Given the anatomical similarities between the canine and human vagus nerves, the results of this study provide a template for better understanding the nerve fiber recruitment patterns associated with VNS therapies.
Tang, Xin; Huang, Fuguo; Chen, Gang; Li, Qi; Fu, Weili; Li, Jian
2018-01-01
To investigate effectiveness of rotator cuff repair with manipulation release and arthroscopic debridement for rotator cuff tear with shoulder stiffness. A retrospectively study was performed on the data of 15 patients with rotator cuff tear combined with shoulder stiffness (stiff group) and 24 patients without stiffness (non-stiff group) between January 2014 and December 2015. The patients in the stiff group underwent arthroscopic rotator cuff repair with manipulation release and arthroscopic debridement while the patients in the non-stiff group only received arthroscopic rotator cuff repair. The patients in the stiff group were older than the patients in the non-stiff group, showing significant difference ( P <0.05). There was no significant difference in gender, type of rotator cuff tear, side of rotator cuff tear, and combined with diabetes between 2 groups ( P >0.05). The visual analogue scale (VAS) score, University of California Los Angeles (UCLA) score, American Shoulder and Elbow Surgeons (ASES) score, and range of motion (ROM) were used to evaluate the effectiveness after operation. All incisions healed by first intention without any complication after operation. The patients were followed up 13-31 months in the stiff group (mean, 19.2 months) and 13-23 months in the non-stiff group (mean, 20.3 months). There was no significant difference in follow- up time between 2 groups ( t =-0.573, P =0.570). The VAS score in the stiff group was higher than that in the non-stiff group before operation ( t =-2.166, P =0.037); there was no significant difference between 2 groups at 3, 6, 12 months and last follow-up ( P >0.05). The forward flexion and external rotation were significantly lower in the stiff group than those in the non-stiff group before operation and at 3 months after operation ( P <0.05); there was no significant difference between 2 groups at 6, 12 months and last follow-up ( P >0.05). At last follow-up, the internal rotation was beyond L 3 level in 2 groups. The preoperative UCLA score was significant lower in the stiff group than that in the non-stiff group ( P =0.037); but there was no significant difference in UCLA score at last follow-up between 2 groups ( P =0.786). There was no significant difference in pre- and post-operative ASES scores between 2 groups ( P >0.05). Satisfactory effectiveness can be achieved in the patients with rotator cuff tear combined with shoulder stiffness after rotator cuff repair with manipulation release and arthroscopic debridement, although the patients with shoulder stiffness had slower postoperative recovery of ROM until 6 months after operation.
A silicon carbide array for electrocorticography and peripheral nerve recording.
Diaz-Botia, C A; Luna, L E; Neely, R M; Chamanzar, M; Carraro, C; Carmena, J M; Sabes, P N; Maboudian, R; Maharbiz, M M
2017-10-01
Current neural probes have a limited device lifetime of a few years. Their common failure mode is the degradation of insulating films and/or the delamination of the conductor-insulator interfaces. We sought to develop a technology that does not suffer from such limitations and would be suitable for chronic applications with very long device lifetimes. We developed a fabrication method that integrates polycrystalline conductive silicon carbide with insulating silicon carbide. The technology employs amorphous silicon carbide as the insulator and conductive silicon carbide at the recording sites, resulting in a seamless transition between doped and amorphous regions of the same material, eliminating heterogeneous interfaces prone to delamination. Silicon carbide has outstanding chemical stability, is biocompatible, is an excellent molecular barrier and is compatible with standard microfabrication processes. We have fabricated silicon carbide electrode arrays using our novel fabrication method. We conducted in vivo experiments in which electrocorticography recordings from the primary visual cortex of a rat were obtained and were of similar quality to those of polymer based electrocorticography arrays. The silicon carbide electrode arrays were also used as a cuff electrode wrapped around the sciatic nerve of a rat to record the nerve response to electrical stimulation. Finally, we demonstrated the outstanding long term stability of our insulating silicon carbide films through accelerated aging tests. Clinical translation in neural engineering has been slowed in part due to the poor long term performance of current probes. Silicon carbide devices are a promising technology that may accelerate this transition by enabling truly chronic applications.
A silicon carbide array for electrocorticography and peripheral nerve recording
NASA Astrophysics Data System (ADS)
Diaz-Botia, C. A.; Luna, L. E.; Neely, R. M.; Chamanzar, M.; Carraro, C.; Carmena, J. M.; Sabes, P. N.; Maboudian, R.; Maharbiz, M. M.
2017-10-01
Objective. Current neural probes have a limited device lifetime of a few years. Their common failure mode is the degradation of insulating films and/or the delamination of the conductor-insulator interfaces. We sought to develop a technology that does not suffer from such limitations and would be suitable for chronic applications with very long device lifetimes. Approach. We developed a fabrication method that integrates polycrystalline conductive silicon carbide with insulating silicon carbide. The technology employs amorphous silicon carbide as the insulator and conductive silicon carbide at the recording sites, resulting in a seamless transition between doped and amorphous regions of the same material, eliminating heterogeneous interfaces prone to delamination. Silicon carbide has outstanding chemical stability, is biocompatible, is an excellent molecular barrier and is compatible with standard microfabrication processes. Main results. We have fabricated silicon carbide electrode arrays using our novel fabrication method. We conducted in vivo experiments in which electrocorticography recordings from the primary visual cortex of a rat were obtained and were of similar quality to those of polymer based electrocorticography arrays. The silicon carbide electrode arrays were also used as a cuff electrode wrapped around the sciatic nerve of a rat to record the nerve response to electrical stimulation. Finally, we demonstrated the outstanding long term stability of our insulating silicon carbide films through accelerated aging tests. Significance. Clinical translation in neural engineering has been slowed in part due to the poor long term performance of current probes. Silicon carbide devices are a promising technology that may accelerate this transition by enabling truly chronic applications.
Teratani, Takeshi
2017-12-01
The purpose of this study was to investigate the prevalence, epidemiology, and outcomes of anterosuperior (A group) rotator cuff tears (RCTs) and posterosuperior (P group) RCTs treated by arthroscopic rotator cuff repair (ARCR). A total of 67 A group patients and 14 P group patients were included in the study. The prevalence of the A group (82.3%) was significantly higher than that of the P group (17.7%). The outcomes in both groups were good, even though the A group had a higher rate of injury to the LHB than the P group. Level III, case-control Study, treatment study.
Adams, Nicola
2014-01-01
Objectives: To conduct a feasibility study to compare concentric and eccentric rotator cuff strengthening exercises for rotator cuff tendinopathy. Methods: A total of 11 patients with rotator cuff tendinopathy who were on the waiting list for arthroscopic subacromial decompression surgery were randomised to perform eccentric rotator cuff strengthening exercises, concentric strengthening exercises or no exercises. Patients were evaluated in terms of levels of pain and function using the Oxford Shoulder Score and a Visual Analogue Scale initially, at 4 weeks and at 8 weeks. Results: The study design was found to be acceptable to patients and achieved a high level of 86% compliance. The drop-out rate was 0%. Two patients performing eccentric strengthening exercises improved sufficiently to cancel their planned surgery. Conclusion: Further research in this area is recommended. The study design was feasible and power calculations have been conducted to aid future research planning. PMID:26770702
Arthroscopic Rotator Cuff Tear Transosseous Repair System: The Sharc-FT Using the Taylor Stitcher.
Pellegrini, Andrea; Lunini, Enricomaria; Rebuzzi, Manuela; Verdano, Michele; Baudi, Paolo; Ceccarelli, Francesco
2015-06-01
Transosseous rotator cuff tear repair was first described in 1944. Over the years, it has represented the gold standard for such lesions. Through open and mini-open approaches, as well as the arthroscopic approach, the transosseous repair system represents one of the most reliable surgical techniques from a biological and mechanical perspective. Nevertheless, further improvements are required. This article describes an arthroscopic rotator cuff tear transosseous repair system, developed in collaboration with NCS Lab (Carpi, Italy): the Sharc-FT using the Taylor Stitcher. Our first experience in the clinical application of the arthroscopic technique using the transosseous suture system has shown encouraging clinical outcomes, confirming its efficacy. The patient satisfaction rate was high, and no patient expressed concern about the implant. The complication rate was very low. By improving the suture technique in the treatment of rotator cuff tears, a remarkable increase in the success rate in the treatment of this pathology could be reached; nevertheless, complications such as retears of the rotator cuff still occur.
Macías-Hernández, Salvador Israel; Pérez-Ramírez, Luis Enrique
2015-01-01
Rotator cuff tears are the leading cause of pain and functional disability of the shoulder. Conservative treatment is an essential part of their management. Despite the limited evidence, rehabilitation is the mainstay of the treatment for rotator cuff tears associated to impingement syndrome. There are current reports on the utility of strengthening with resistance, particularly by eccentric exercise. This report aims to present an overview of the efficacy of eccentric exercises in tendinopathies and current evidence of its benefit in rotator cuff tears. We describe the information available in tendinopathy and analyzed four studies published on eccentric strengthening for rotator cuff tears. There is theoretical evidence about its usefulness in this pathology, but only a controlled clinical trial has been published with data on improvement in strength but not in pain or functionality. More studies are needed with better methodological designs in order to generate evidence of their utility and recommendation. Copyright © 2015. Published by Masson Doyma México S.A.
Biomaterials based strategies for rotator cuff repair.
Zhao, Song; Su, Wei; Shah, Vishva; Hobson, Divia; Yildirimer, Lara; Yeung, Kelvin W K; Zhao, Jinzhong; Cui, Wenguo; Zhao, Xin
2017-09-01
Tearing of the rotator cuff commonly occurs as among one of the most frequently experienced tendon disorders. While treatment typically involves surgical repair, failure rates to achieve or sustain healing range from 20 to 90%. The insufficient capacity to recover damaged tendon to heal to the bone, especially at the enthesis, is primarily responsible for the failure rates reported. Various types of biomaterials with special structures have been developed to improve tendon-bone healing and tendon regeneration, and have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects. In this review, we first give a brief introduction of the anatomy of the rotator cuff and then discuss various design strategies to augment rotator cuff repair. Furthermore, we highlight current biomaterials used for repair and their clinical applications as well as the limitations in the literature. We conclude this article with challenges and future directions in designing more advanced biomaterials for augmentation of rotator cuff repair. Copyright © 2017 Elsevier B.V. All rights reserved.
Automated Control of Endotracheal Tube Cuff Pressure during Simulated Flight
2016-06-21
accomplished in the intensive care unit (ICU) with stand-alone devices as well as those integral to a ventilator [13,14]. We hypothesized that closed loop ... Administration approved automatic cuff pressure adjustment devices (Intellicuff, Hamilton Medical , Reno, NV; Pyton, ARM Medical , Bristol, CT; Cuff Sentry, Outcome...711th Human Performance Wing U.S. Air Force School of Aerospace Medicine Int’l Expeditionary Educ & Training Dept Air Force Expeditionary Medical
Rotator Cuff Tear Arthropathy: Pathophysiology, Imaging Characteristics, and Treatment Options.
Eajazi, Alireza; Kussman, Steve; LeBedis, Christina; Guermazi, Ali; Kompel, Andrew; Jawa, Andrew; Murakami, Akira M
2015-11-01
The purpose of this article is to review the biomechanical properties of the rotator cuff and glenohumeral joint and the pathophysiology, imaging characteristics, and treatment options of rotator cuff tear arthropathy (RCTA). Although multiple pathways have been proposed as causes of RCTA, the exact cause remains unclear. Increasing knowledge about the clinical diagnosis, imaging features, and indicators of severity improves recognition and treatment of this pathologic condition.
Murakami, Naoya; Norihisa, Yoshiki; Isohashi, Fumiaki; Murofushi, Keiko; Ariga, Takuro; Kato, Tomoyasu; Inaba, Koji; Okamoto, Hiroyuki; Ito, Yoshinori; Toita, Takafumi; Itami, Jun
2016-01-01
The aim of this study was to develop an appropriate definition for vaginal cuff and paracolpium clinical target volume (CTV) for postoperative intensity modulated radiation therapy in patients with uterine cervical cancer. A working subgroup was organized within the Radiation Therapy Study Group of the Japan Clinical Oncology Group to develop a definition for the postoperative vaginal cuff and paracolpium CTV in December 2013. The group consisted of 5 radiation oncologists who specialized in gynecologic oncology and a gynecologic oncologist. A comprehensive literature review that included anatomy, surgery, and imaging fields was performed and was followed by multiple discreet face-to-face discussions and e-mail messages before a final consensus was reached. Definitions for the landmark structures in all directions that demarcate the vaginal cuff and paracolpium CTV were decided by consensus agreement of the working group. A table was created that showed boundary structures of the vaginal cuff and paracolpium CTV in each direction. A definition of the postoperative cervical cancer vaginal cuff and paracolpium CTV was developed. It is expected that this definition guideline will serve as a template for future radiation therapy clinical trial protocols, especially protocols involving intensity modulated radiation therapy. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Pai Raikar, Vipul; Kwartowitz, David M.
2016-04-01
Degradation and injury of the rotator cuff is one of the most common diseases of the shoulder among the general population. In orthopedic injuries, rotator cuff disease is only second to back pain in terms of overall reduced quality of life for patients. Clinically, this disease is managed via pain and activity assessment and diagnostic imaging using ultrasound and MRI. Ultrasound has been shown to have good accuracy for identification and measurement of rotator cuff tears. In our previous work, we have developed novel, real-time techniques to biomechanically assess the condition of the rotator cuff based on Musculoskeletal Ultrasound. Of the rotator cuff tissues, supraspinatus is the first that sees degradation and is the most commonly affected. In our work, one of the challenges lies in effectively segmenting and characterizing the supraspinatus. We are exploring the possibility of using curvelet transform for improving techniques to segment tissue in ultrasound. Curvelets have been shown to give optimal multi-scale representation of edges in images. They are designed to represent edges and singularities along curves in images which makes them an attractive proposition for use in ultrasound segmentation. In this work, we present a novel approach to the possibility of using curvelet transforms for automatic edge and feature extraction for the supraspinatus.
Manafi-Khanian, Bahram; Arendt-Nielsen, Lars; Graven-Nielsen, Thomas
2016-03-01
Cuff pressure stimulation is applicable for assessing deep-tissue pain sensitivity by exciting a variety of deep-tissue nociceptors. In this study, the relative transfer of biomechanical stresses and strains from the cuff via the skin to the muscle and the somatic tissue layers around bones were investigated. Cuff pressure was applied on the lower leg at three different stimulation intensities (mild pressure to pain). Three-dimensional finite element models including bones and three different layers of deep tissues were developed based on magnetic resonance images (MRI). The skin indentation maps at mild pressure, pain threshold, and intense painful stimulations were extracted from MRI and applied to the model. The mean stress under the cuff position around tibia was 4.6, 4.9 and around fibula 14.8, 16.4 times greater than mean stress of muscle surface in the same section at pain threshold and intense painful stimulations, respectively. At the same stimulation intensities, the mean strains around tibia were 36.4, 42.3 % and around fibula 32.9, 35.0 %, respectively, of mean strain on the muscle surface. Assuming strain as the ideal stimulus for nociceptors the results suggest that cuff algometry is less capable to challenge the nociceptors of tissues around bones as compared to more superficially located muscles.
Longo, Umile Giuseppe; Saris, Daniël; Poolman, Rudolf W; Berton, Alessandra; Denaro, Vincenzo
2012-10-01
The aims of this study were to obtain an overview of the methodological quality of studies on the measurement properties of rotator cuff questionnaires and to describe how well various aspects of the design and statistical analyses of studies on measurement properties are performed. A systematic review of published studies on the measurement properties of rotator cuff questionnaires was performed. Two investigators independently rated the quality of the studies using the Consensus-based Standards for the selection of health Measurement Instruments checklist. This checklist was developed in an international Delphi consensus study. Sixteen studies were included, in which two measurement instruments were evaluated, namely the Western Ontario Rotator Cuff Index and the Rotator Cuff Quality-of-Life Measure. The methodological quality of the included studies was adequate on some properties (construct validity, reliability, responsiveness, internal consistency, and translation) but need to be improved on other aspects. The most important methodological aspects that need to be developed are as follows: measurement error, content validity, structural validity, cross-cultural validity, criterion validity, and interpretability. Considering the importance of adequate measurement properties, it is concluded that, in the field of rotator cuff pathology, there is room for improvement in the methodological quality of studies measurement properties. II.
Gender, ethnicity and smoking affect pain and function in patients with rotator cuff tears.
Maher, Anthony; Leigh, Warren; Brick, Matt; Young, Simon; Millar, James; Walker, Cameron; Caughey, Michael
2017-09-01
This study is a collation of baseline demographic characteristics of those presenting for rotator cuff repair in New Zealand, and exploration of associations with preoperative function and pain. Data were obtained from the New Zealand Rotator Cuff Registry; a multicentre, nationwide prospective cohort of rotator cuff repairs undertaken from 1 March 2009 until 31 December 2010. A total of 1383 patients were included in the study. This required complete demographic information, preoperative Flex-SF (functional score) and pain scores. Following univariate analysis, a multivariate model was used. The average age was 58 years (69% males and 11% smokers). New Zealand Europeans made up 90% and Maori 5%. The average preoperative Flex-SF was significantly lower (poorer function) in those over 65 years, females, smokers and Maori, in the non-dominant patients, using a multivariate model. Average preoperative pain scores were significantly worse (higher scores) in females, Maori, Polynesians, smokers, using a multivariate model. This is the largest reported prospective cohort of patients presenting for rotator cuff surgery. Results can be used to understand the effect of rotator cuff tears on the different patients, for example Maori patients who are under-represented, present younger, with more pain and poorer function. © 2017 Royal Australasian College of Surgeons.
Petri, Maximilian; Greenspoon, Joshua A.; Bhatia, Sanjeev; Millett, Peter J.
2015-01-01
Latissimus dorsi transfer is a reasonable treatment option for massive posterosuperior rotator cuff tears that can substantially improve chronically painful and dysfunctional shoulders. This report and accompanying video describe the treatment of an active 43-year-old man with severe pain and weakness in the right shoulder after 3 failed rotator cuff repairs. Preoperative imaging showed a massive posterosuperior rotator cuff tear retracted to the glenoid as well as a hypermobile os acromiale likely causing dynamic impingement and recurrent rotator cuff tears. After diagnostic arthroscopy, the latissimus tendon is harvested and augmented with a 3-mm human acellular dermal patch (ArthroFlex; Arthrex, Naples, FL). The native rotator cuff tissue is repaired as much as possible, and the latissimus tendon is passed underneath the deltoid and posterior to the teres minor. The patch-augmented tendon is then integrated into a double-row SpeedBridge repair of eight 4.75-mm BioComposite SwiveLock anchors (Arthrex). The bony surface of the os acromiale is prepared and then fixed to the acromion with 2 cannulated partially threaded screws and additional tension-band wiring. Postoperative rehabilitation initially focuses on early passive range of motion, followed by active and active-assisted motion and a biofeedback program starting at 6 weeks postoperatively. PMID:26697309
The impact of rotator cuff tendinopathy on proprioception, measuring force sensation.
Maenhout, Annelies G; Palmans, Tanneke; De Muynck, Martine; De Wilde, Lieven F; Cools, Ann M
2012-08-01
The impact of rotator cuff tendinopathy and related impingement on proprioception is not well understood. Numerous quantitative and qualitative changes in shoulder muscles have been shown in patients with rotator cuff tendinopathy. These findings suggest that control of force might be affected. This investigation wants to evaluate force sensation, a submodality of proprioception, in patients with rotator cuff tendinopathy. Thirty-six patients with rotator cuff tendinopathy and 30 matched healthy subjects performed force reproduction tests to isometric external and internal rotation to investigate how accurately they could reproduce a fixed target (50% MVC). Relative error, constant error, and force steadiness were calculated to evaluate respectively magnitude of error made during the test, direction of this error (overshoot or undershoot), and fluctuations of produced forces. Patients significantly overshoot the target (mean, 6.04% of target) while healthy subjects underestimate the target (mean, -5.76% of target). Relative error and force steadiness are similar in patients with rotator cuff tendinopathy and healthy subjects. Force reproduction tests, as executed in this study, were found to be highly reliable (ICC 0.849 and 0.909). Errors were significantly larger during external rotation tests, compared to internal rotation. Patients overestimate the target during force reproduction tests. This should be taken into account in the rehabilitation of patients with rotator cuff tendinopathy; however, precision of force sensation and steadiness of force exertion remains unaltered. This might indicate that control of muscle force is preserved. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Omid, Reza; Heckmann, Nathanael; Wang, Lawrence; McGarry, Michelle H; Vangsness, C Thomas; Lee, Thay Q
2015-10-01
The purpose of this study was to characterize the biomechanical effects of the lower trapezius transfer and to compare it with the latissimus dorsi transfer in a cadaveric model of a massive posterosuperior rotator cuff tear. Eight cadaveric shoulders were tested at 0°, 30°, and 60° of shoulder abduction. Range of motion, humeral rotational position due to muscle loading, joint reaction forces, and kinematics were measured. All specimens were tested in 4 conditions: intact, massive posterosuperior cuff tear, lower trapezius transfer, and latissimus dorsi transfer. A repeated-measures analysis of variance was used for statistical analysis. Internal rotation due to muscle loading increased with massive cuff tear compared with the intact condition (P < .05). The latissimus transfer corrected this change at 0° abduction, whereas the trapezius transfer corrected this at all abduction angles. The massive cuff tear decreased glenohumeral joint compression forces at all abduction angles; these forces were restored by the lower trapezius transfer (P < .05). At maximum humeral internal rotation and 0° of abduction, the humeral head apex shifted superiorly and laterally with massive cuff tear (P < .05); this shift was more closely restored to intact values by the trapezius transfer compared with the latissimus transfer (P < .05). The lower trapezius transfer is superior to the latissimus transfer at restoring native glenohumeral kinematics and joint reaction forces in our cadaveric model. It may be a promising treatment option for patients with a massive irreparable rotator cuff tear. Published by Elsevier Inc.
Partial repair in irreparable rotator cuff tear: our experience in long-term follow-up.
Di Benedetto, E D; Di Benedetto, Paolo; Fiocchi, Andrea; Beltrame, Alessandro; Causero, Araldo
2017-10-18
Massive rotator cuff tears are a common source of shoulder pain and dysfunction, especially in middle age patient; these lesions represent about 20% of all rotator cuff tears and 80% of recurrent tears. Some lesions are not repairable or should not be repaired: in this case, a rotator cuff partial repair should be recommended. The aim of the study is to evaluate the outcome of rotator cuff partial repair in irreparable rotator cuff massive tear at medium and long-term follow-up. We have evaluated 74 consecutive patients treated with functional repair of rotator cuff by the same surgeon between 2006 and 2014. We divided patients into 2 groups, obtaining 2 average follow-up: at about 6,5 (group A) and 3 years (group B). In December 2015, we evaluated in every patient ROM and Constant Score. We analyzed difference between pre-operatory data and the 2 groups. Results: We found statistical significant difference in ROM and in Constant Score between pre-operatory data and group A and group B. Between group A and group B there is relevant difference in Constant Score but not in ROM. Partial repair can give good results in a medium follow-up, in terms of pain relief and improvement of ROM, as well as in quality of life. Difference in ROM and Constant Score between group A and group B may indicate the begin of partial repair failure; according to our data, 6-7 years may be the time limit for this surgery technique.
Rotator cuff tendon connections with the rotator cable.
Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo
2017-07-01
The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.
Jacobson, Jon A.; Benson, Carol B.; Bancroft, Laura W.; Bedi, Asheesh; McShane, John M.; Miller, Theodore T.; Parker, Laurence; Smith, Jay; Steinbach, Lynne S.; Teefey, Sharlene A.; Thiele, Ralf G.; Tuite, Michael J.; Wise, James N.; Yamaguchi, Ken
2013-01-01
The Society of Radiologists in Ultrasound convened a panel of specialists from a variety of medical disciplines to reach a consensus about the recommended imaging evaluation of painful shoulders with clinically suspected rotator cuff disease. The panel met in Chicago, Ill, on October 18 and 19, 2011, and created this consensus statement regarding the roles of radiography, ultrasonography (US), computed tomography (CT), CT arthrography, magnetic resonance (MR) imaging, and MR arthrography. The consensus panel consisted of two co-moderators, a facilitator, a statistician and health care economist, and 10 physicians who have specialty expertise in shoulder pain evaluation and/or treatment. Of the 13 physicians on the panel, nine were radiologists who were chosen to represent a broad range of skill sets in diagnostic imaging, different practice types (private and academic), and different geographical regions of the United States. Five of the radiologists routinely performed musculoskeletal US as part of their practice and four did not. There was also one representative from each of the following clinical specialties: rheumatology, physical medicine and rehabilitation, orthopedic surgery, and nonoperative sports medicine. The goal of this conference was to construct several algorithms with which to guide the imaging evaluation of suspected rotator cuff disease in patients with a native rotator cuff, patients with a repaired rotator cuff, and patients who have undergone shoulder replacement. The panel hopes that these recommendations will lead to greater uniformity in rotator cuff imaging and more cost-effective care for patients suspected of having rotator cuff abnormality. © RSNA, 2013 PMID:23401583
Urita, Atsushi; Funakoshi, Tadanao; Horie, Tatsunori; Nishida, Mutsumi; Iwasaki, Norimasa
2017-01-01
Vascularity is the important factor of biologic healing of the repaired tissue. The purpose of this study was to clarify sequential vascular patterns of repaired rotator cuff by suture techniques. We randomized 21 shoulders in 20 patients undergoing arthroscopic rotator cuff repair into 2 groups: transosseous-equivalent repair (TOE group, n = 10) and transosseous repair (TO group, n = 11). Blood flow in 4 regions inside the cuff (lateral articular, lateral bursal, medial articular, and medial bursal), in the knotless suture anchor in the TOE group, and in the bone tunnel in the TO group was measured using contrast-enhanced ultrasound at 1 month, 2 months, 3 months, and 6 months postoperatively. The sequential vascular pattern inside the repaired rotator cuff was different between groups. The blood flow in the lateral articular area at 1 month, 2 months, and 3 months (P = .002, .005, and .025) and that in the lateral bursal area at 2 months (P = .031) in the TO group were significantly greater than those in the TOE group postoperatively. Blood flow was significantly greater for the bone tunnels in the TO group than for the knotless suture anchor in the TOE group at 1 month and 2 months postoperatively (P = .041 and .009). This study clarified that the sequential vascular pattern inside the repaired rotator cuff depends on the suture technique used. Bone tunnels through the footprint may contribute to biologic healing by increasing blood flow in the repaired rotator cuff. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
[Shoulder calcifying tendinitis].
Clavert, P; Sirveaux, F
2008-12-01
Calcifying tendinitis is a frequent shoulder disease but the surgical treatment is still debatable. The authors of this symposium reviewed retrospectively 450 patients treated by arthroscopal excision for calcifying tendinitis. Imaging were used to assess the cuff status in every case. The minimum follow-up was five years except for subscapularis and infraspinatus calcification (minimum two years). At the same time, we led a prospective study evaluating the prevalence of the calcifications on 1276 asymptomatic shoulders. The prevalence of rotator cuff calcification was 7.3%, with a female predominance specially in the operated group. Calcifications have been found as well in patients more than 70 years old. The inter- and intraobserver agreement for the A-B-C classification was poor, specially to differentiate the type A and B calcifications. The long-term follow-up allows to prove that the calcifying tendinitis is temporary without any relation with rotator cuff rupture. Recurrence of the calcific deposit after complete disappearance was never observed and the rate of full thickness tears was 3.9% at an average of nine years follow-up (mean age 56 years). These findings allowed to conclude than cuff suture after removing the deposit is not mandatory. However, the preoperative cuff status had a significant influence on the functional results at follow-up. Preoperative associated partial tear of the cuff or a preoperative positive Jobe test affected significantly the results and increased the rate of full thickness tear at follow-up. The subscapularis calcifications were rare (6% of the calcifications) and were associated with further deposit on the cuff. Infraspinatus calcifications were more frequent (20%), mostly associated to over tendons calcifications. The arthroscopic treatment obtained good results independently from the calcification location but the surgical approach should be adapted. Functional results were lower after removing a type C calcification. Acromioplasty improved the results when the calcification was associated with an aggressive acromion or a partial cuff tear.
Blot, Stijn I; Poelaert, Jan; Kollef, Marin
2014-11-28
Microaspiration of subglottic secretions through channels formed by folds in high volume-low pressure poly-vinyl chloride cuffs of endotracheal tubes is considered a significant pathogenic mechanism of ventilator-associated pneumonia (VAP). Therefore a series of prevention measures target the avoidance of microaspiration. However, although some of these can minimize microaspiration, benefits in terms of VAP prevention are not always obvious. Polyurethane-cuffed endotracheal tubes successfully reduce microaspiration but high quality data demonstrating VAP rate reduction are lacking. An analogous conclusion can be made regarding taper-shaped cuffs compared with classic barrel-shaped cuffs. More clinical data regarding these endotracheal tube designs are needed to demonstrate clinical value in addition to in vitro-based evidence. The clinical usefulness of endotracheal tubes developed for subglottic secretions drainage is established in multiple studies and confirmed by meta-analysis. Any change in cuff design will fail to prevent microaspiration if the cuff is insufficiently inflated. At least one well-designed trial demonstrated that continuous cuff pressure monitoring and control decrease the risk of VAP. Gel lubrication of the cuff prior to intubation temporarily hampers microaspiration through sludging the channels formed by folds in high volume-low pressure cuffs. As the beneficial effect of gel lubrication is temporarily, its potential to reduce VAP risk is probably nonsignificant. A minimum positive end-expiratory pressure of at least 5 cmH2O can be recommended as it reduces the risk of microaspiration in vitro and in vivo. One randomized controlled study demonstrated a reduced risk of VAP in patients ventilated with PEEP (5-8 cmH2O). Regarding head-of-bed elevation, it can be recommended to avoid supine positioning. Whether a 45° head-of-bed elevation is to be preferred above 25-30° head-of-bed elevation remains unproven. Finally, the routine monitoring of gastric residual volumes in mechanically ventilated patients receiving enteral nutrition cannot be recommended.
Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan
2014-12-01
This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P < 0.001, 95% confidence interval -3.5 to -2.1 mm Hg). Since it is known that the traditional Korotkoff sound method, with the stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.
Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan
2014-01-01
Abstract This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P < 0.001, 95% confidence interval −3.5 to −2.1 mm Hg). Since it is known that the traditional Korotkoff sound method, with the stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP. PMID:25546675
Jensen, Andrew R; Cha, Peter S; Devana, Sai K; Ishmael, Chad; Di Pauli von Treuheim, Theo; D'Oro, Anthony; Wang, Jeffrey C; McAllister, David R; Petrigliano, Frank A
2017-10-01
Medicare insures the largest population of patients at risk for rotator cuff tears in the United States. To evaluate the trends in incidence, concomitant procedures, and complications with open and arthroscopic rotator cuff repairs in Medicare patients. Cohort study; Level of evidence, 3. All Medicare patients who had undergone open or arthroscopic rotator cuff repair from 2005 through 2011 were identified with a claims database. Annual incidence, concomitant procedures, and postoperative complications were compared between these 2 groups. In total, 372,109 rotator cuff repairs were analyzed. The incidence of open repairs decreased (from 6.0 to 4.3 per 10,000 patients, P < .001) while the incidence of arthroscopic repairs increased (from 4.5 to 7.8 per 10,000 patients, P < .001) during the study period. Patients in the arthroscopic group were more likely to have undergone concomitant subacromial decompression than those in the open group (87% vs 35%, P < .001), and the annual incidence of concomitant biceps tenodesis increased for both groups (from 3.8% to 11% for open and 2.2% to 16% for arthroscopic, P < .001). While postoperative complications were infrequent, patients in the open group were more likely to be diagnosed with infection within 6 months (0.86% vs 0.37%, P < .001) but no more likely to undergo operative debridement (0.43% vs 0.26%, P = .08). Additionally, patients in the open group were more likely to undergo intervention for shoulder stiffness within 1 year (1.4% vs 1.1%, P = .01). In the Medicare population, arthroscopic rotator cuff repairs have increased in incidence and now represent the majority of rotator cuff repair surgery. Among concomitant procedures, subacromial decompression was most commonly performed despite evidence suggesting a lack of efficacy. Infections and stiffness were rare complications that were slightly but significantly more frequent in open rotator cuff repairs.
Jensen, Andrew R.; Cha, Peter S.; Devana, Sai K.; Ishmael, Chad; Di Pauli von Treuheim, Theo; D’Oro, Anthony; Wang, Jeffrey C.; McAllister, David R.; Petrigliano, Frank A.
2017-01-01
Background: Medicare insures the largest population of patients at risk for rotator cuff tears in the United States. Purpose: To evaluate the trends in incidence, concomitant procedures, and complications with open and arthroscopic rotator cuff repairs in Medicare patients. Study Design: Cohort study; Level of evidence, 3. Methods: All Medicare patients who had undergone open or arthroscopic rotator cuff repair from 2005 through 2011 were identified with a claims database. Annual incidence, concomitant procedures, and postoperative complications were compared between these 2 groups. Results: In total, 372,109 rotator cuff repairs were analyzed. The incidence of open repairs decreased (from 6.0 to 4.3 per 10,000 patients, P < .001) while the incidence of arthroscopic repairs increased (from 4.5 to 7.8 per 10,000 patients, P < .001) during the study period. Patients in the arthroscopic group were more likely to have undergone concomitant subacromial decompression than those in the open group (87% vs 35%, P < .001), and the annual incidence of concomitant biceps tenodesis increased for both groups (from 3.8% to 11% for open and 2.2% to 16% for arthroscopic, P < .001). While postoperative complications were infrequent, patients in the open group were more likely to be diagnosed with infection within 6 months (0.86% vs 0.37%, P < .001) but no more likely to undergo operative debridement (0.43% vs 0.26%, P = .08). Additionally, patients in the open group were more likely to undergo intervention for shoulder stiffness within 1 year (1.4% vs 1.1%, P = .01). Conclusion: In the Medicare population, arthroscopic rotator cuff repairs have increased in incidence and now represent the majority of rotator cuff repair surgery. Among concomitant procedures, subacromial decompression was most commonly performed despite evidence suggesting a lack of efficacy. Infections and stiffness were rare complications that were slightly but significantly more frequent in open rotator cuff repairs. PMID:29051905
Rhee, Yong Girl; Cho, Nam Su; Song, Jong Hoon; Park, Jung Gwan; Kim, Tae Yong
2017-09-01
If the balance of the rotator cuff force couple is disrupted, pseudoparalysis may occur, but the exact mechanism remains unknown. This study investigated the effect of rotator cuff force couple disruption on active range of motion in massive rotator cuff tear (mRCT) by rotator cuff muscle volume analysis. The study included 53 patients with irreparable mRCT: 22 in the nonpseudoparalysis group and 31 in the pseudoparalysis group. The volumes of the subscapularis (SBS), infraspinatus (ISP), and teres minor (TM) muscles were measured using magnetic resonance imaging (MRI), and the ratios of each muscle volume to the anatomic external rotator (aER) volume were calculated. A control group of 25 individuals with normal rotator cuffs was included. Anterior-to-posterior cuff muscle volume ratio (SBS/ISP + TM) was imbalanced in both mRCT groups (1.383 nonpseudoparalysis and 1.302 pseudoparalysis). Between the 2 groups, the ISP/aER ratio (0.277 vs. 0.249) and the inferior SBS/aER ratio (0.426 vs. 0.390) were significantly decreased in the pseudoparalysis group (P= .022 and P= .040, respectively). However, neither the TM/aER ratio (0.357 vs. 0.376) nor the superior SBS/aER ratio (0.452 vs. 0.424) showed a significant difference between the two groups (P= .749 and P= .068, respectively). If the inferior SBS was torn, a high frequency of pseudoparalysis was noted (81.0%, P= .010). The disruption of transverse force couple was noted in both irreparable mRCT groups, although no significant difference was found between the nonpseudoparalysis and pseudoparalysis groups. ISP and inferior SBS muscle volumes showed a significant decrease in pseudoparalysis group and, therefore, were considered to greatly influence the loss of active motion in mRCT. The TM did not exert significant effect on the incidence of pseudoparalysis. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Lewington, Matthew R; Ferguson, Devin P; Smith, T Duncan; Burks, Robert; Coady, Catherine; Wong, Ivan Ho-Bun
2017-11-01
Rotator cuff tears are one of the most common conditions affecting the shoulder. Because of the difficulty in managing massive rotator cuff tears and the inability of standard techniques to prevent arthropathy, surgeons have developed several novel techniques to improve outcomes and ideally alter the natural history. To systematically review the existing literature and analyze reported outcomes to evaluate the effectiveness of using a bridging graft reconstruction technique to treat large to massive irreparable rotator cuff tears. Systematic review. A systematic search of PubMed, EMBASE, CINAHL, and CENTRAL was employed with the key terms "tear," "allograft," and "rotator cuff." Eligibility was determined by a 3-phase screening process according to the outlined inclusion/exclusion criteria. Data in relation to the primary and secondary outcomes were summarized. The results were synthesized according to the origin of the graft and the level of evidence. Fifteen studies in total were included in this review: 2 comparative studies and 13 observational case series. Both the biceps tendon and the fascia lata autograft groups had significantly superior structural integrity rates on magnetic resonance imaging at 12-month minimum follow-up when compared with their partial primary repair counterparts (58% vs 26%, P = .036; 79% vs 58%, P < .05), respectively. Multiple noncomparative case series investigating allografts, xenografts, and synthetic materials for bridging reconstruction of large to massive rotator cuff tears demonstrated high structural healing rates (74%-90%, 73%-100%, and 60%-90%, respectively). Additionally, both comparative studies and case series demonstrated a general improvement of patients' functional outcome scores. Using a graft for an anatomic bridging rotator cuff repair results in improved function on objective testing and may be functionally better than nonanatomic or partial repair of large to massive rotator cuff tears. Allograft or xenograft techniques appear to be favorable options, given demonstrated functional improvement, imaging-supported graft survival, and lack of harvest complication risk. More high-quality randomized controlled studies are needed to further assess this technique.
Gumina, S; Candela, V; Mariani, L; Venditto, T; Catalano, C; Castellano, S; Santilli, V; Giannicola, G; Castagna, A
2018-01-01
In order to evaluate whether overuse has a significant role in rotator cuff tear (RCT) aetiology, we evaluated both shoulders of patients with old unilateral arm amputation expecting a higher rate of RC degeneration in the healthy side. Nineteen males and six females (mean age: 57.3 ± 10.1) with an old (>20 years) unilateral arm amputation were submitted to an MRI of both shoulders. Tendon status and muscle tropism were evaluated according to Sugaya and Fuchs classifications, respectively; the acromion humeral distance was measured. Statistical analysis was performed to verify the prevalence of Sugaya and Fuchs categories in each sides. A significant prevalence of Sugaya type II in the amputated side (p = 0.02) and of type I in the healthy side (p < 0.001) was found. Rotator cuff was healthy in 28 and 52% of amputated and non-amputated side, respectively. The mean acromio-humeral distances of the amputated and healthy side were 0.8 cm (SD: 0.1) and 0.9 cm (SD: 0.1), respectively, (p = 0.02). A significant prevalence of Fuchs type II category in the healthy side (p < 0.001) was found. Fuchs III/IV were observed in 40 and 12% of amputated and healthy side, respectively. The present study resizes the role of overuse on the aetiology of RCT. Cuff tear prevalence in not amputated shoulders, inevitably submitted to functional overload, was not higher than that of coetaneous subjects with two functional upper limbs. Shoulder non-use is a risk factor for rotator cuff tear. As the prevalence of rotator cuff degeneration/tear is higher in the amputee side, non-use is a more relevant risk factor than overuse. In the daily clinical practice, patients with rotator cuff tear should be encouraged to shoulder movement because rotator cuff tendon status could be worsened by disuse. III.
Cuff, Derek J; Pupello, Derek R; Santoni, Brandon G
2016-11-01
A subset of patients with massive irreparable rotator cuff tears present with retained overhead elevation and pain as their primary complaint. Our aim was to evaluate the outcomes of partial arthroscopic rotator cuff repair with biceps tenotomy and to report the failure rate of this procedure for patients with >5 years of follow-up. Thirty-four patients underwent partial rotator cuff repair and biceps tenotomy for treatment of a massive rotator cuff tear. Patients had preoperative active forward elevation >120° and no radiographic evidence of glenohumeral arthritis. Patients were followed up clinically and radiographically, and 28 patients had a minimum of 5 years of follow-up. Failure was defined as an American Shoulder and Elbow Surgeons score of <70, loss of active elevation >90°, or revision to reverse shoulder arthroplasty during the study period. Patients demonstrated improvements in average preoperative to postoperative American Shoulder and Elbow Surgeons scores (46.6 to 79.3 [P < .001]) and Simple Shoulder Test scores (5.7 to 9.1 [P < .001]) along with decrease in visual analog scale for pain scores (6.9 to 1.9 [P < .001]). No significant change in forward elevation (168° to 154° [P = .07]), external rotation (38° to 39° [P = 1.0]), or internal rotation (84% to 80% [P = 1.0]) was identified; 36% of patients had progression of the Hamada stage. The failure rate was 29%; 75% of patients were satisfied with their index procedure. Partial rotator cuff repair and biceps tenotomy for patients with massive irreparable rotator cuff tears with retained overhead elevation and pain as the primary complaint produced reasonable outcomes at midterm follow-up of at least 5 years. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Taniguchi, Noboru; D'Lima, Darryl D; Suenaga, Naoki; Chosa, Etsuo
2018-02-01
Failure rates after rotator cuff repair remain high in patients with massive tears. Although superior translation of the humeral head has been used to assess the severity of rotator cuff tears, the relevance of anterior migration of the humeral head to clinical outcomes has not been established. The purpose of this study was to investigate the potential role of the T-scale, a measure of the anterolateral translation of the humeral head, as a prognostic factor for rotator cuff repair. One hundred twenty consecutive patients with full-thickness rotator cuff tears underwent primary rotator cuff repair. The T-scale and acromiohumeral interval (AHI) were measured preoperatively on axial computed tomography scans and radiographs, respectively. The correlations of the T-scale and AHI with previously published scores and active forward elevation (FE) were investigated. The outcome of rotator cuff repairs was compared between patients with positive and patients with negative preoperative T-scale values. The preoperative T-scale but not AHI correlated significantly with postoperative FE and clinical scores in patients with large to massive tears but not in those with small to medium tears. Postoperative FE and clinical scores were significantly higher in patients with positive T-scale values than in those with negative T-scale values. The relative risk of retear was 2.0 to 7.9 times greater in patients with negative T-scale values. Patients with large to massive tears and negative T-scale values had poorer clinical outcomes and higher retear rates. A negative T-scale value represents a useful prognostic factor for considering reverse shoulder arthroplasty in patients at greater risk of retear after rotator cuff repair. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Proximal Long Head Biceps Rupture: A Predictor of Rotator Cuff Pathology.
Kowalczuk, Marcin; Kohut, Kevin; Sabzevari, Soheil; Naendrup, Jan-Hendrik; Lin, Albert
2018-04-01
To investigate whether acute rupture of the proximal long head biceps is a harbinger of disease of the nearby supraspinatus and subscapularis tendons. A retrospective chart review from February 1, 2008, to August 31, 2016, was performed at our institution identifying patients who presented with an acute (<12-week) history of "Popeye" deformity of the distal biceps and a magnetic resonance imaging (MRI) of the affected shoulder. MRI images were then reviewed in duplicate to determine supraspinatus and subscapularis tendon tear incidence, size, chronicity, and depth. The association between rotator cuff status and acute long head biceps rupture as well as patient age, sex, smoking status, hand dominance, and history of diabetes mellitus or trauma was then evaluated. A total of 116 patients were included in this study (mean age: 61.9 ± 10.9 years). A significant proportion (n = 99; incidence: 85%) were found to have some degree of supraspinatus or subscapularis tendon tearing on MRI (P < .001). These patients were also found to be significantly older compared with those with an intact rotator cuff (mean age 63.3 ± 10.7 vs 54.2 ± 9.2; P = .001). Full thickness rotator cuff tears were significantly more likely to involve the supraspinatus as opposed to the subscapularis (incidence: 44% and 21%; P = .002). Despite the expected association of rotator cuff disease with increasing patient age, the results of this study also affirm the hypothesis that inflammation in the rotator cuff interval signaled by rupture of the long head of biceps is a harbinger of rotator cuff disease. Clinicians should have a high index of suspicion regarding concomitant anterosuperior rotator cuff pathology in patients presenting with acute long head of biceps rupture. Early evaluation with advanced imaging should be strongly considered. Level IV, case series. Published by Elsevier Inc.
The prevalence of rotator cuff tears: is the contralateral shoulder at risk?
Liem, Dennis; Buschmann, Vera Elisa; Schmidt, Carolin; Gosheger, Georg; Vogler, Tim; Schulte, Tobias L; Balke, Maurice
2014-04-01
Rotator cuff tears are a common cause of pain and disability of the shoulder. Information on the prevalence and identification of potential risk factors could help in early detection of rotator cuff tears and improve treatment outcome. Patients treated for a symptomatic rotator cuff tear on one side have a higher prevalence of rotator cuff tears and decreased shoulder function on the contralateral side compared with an age- and sex-matched group of healthy individuals. Case control study; Level of evidence, 3. One group consisted of 55 patients who had been arthroscopically treated on one shoulder for rotator cuff tear (tear group). In this group, the nonoperated contralateral shoulder was examined. For comparison, the matching shoulder in a control group consisting of 55 subjectively healthy individuals matched by age (±1 year) and sex to the tear group was included. Diagnosis of a rotator cuff tear was made by ultrasound. Outcomes were measured using the Constant score. The prevalence of supraspinatus tears was significantly higher (P < .0001) in the tear group (67.3%) compared with the control group (11.0%). The Constant score for the activities of daily living subscale, however, was significantly lower (18.4) in the tear group compared with the control group (19.9; P = .012). No other subcategory score nor the overall score showed a significant difference. There was a significantly higher tear prevalence in the tear group of patients aged between 50 and 59 years (P < .001) and 60 and 69 years (P = .004). No tear was diagnosed in the control group in individuals younger than 60 years. Patients treated for partial and full-thickness rotator cuff tears have a significantly higher risk of having a tear on the contralateral side and have noticeable deficits in their shoulder function regarding activities of daily living even if the tear is otherwise asymptomatic.
Postoperative stiff shoulder after open rotator cuff repair: a 3- to 20-year follow-up study.
Vastamäki, H; Vastamäki, M
2014-12-01
Stiffness after a rotator cuff tear is common. So is stiffness after an arthroscopic rotator cuff repair. In the literature, however, postoperative restriction of passive range of motion after open rotator cuff repair in shoulders with free passive range of motion at surgery has seldom been recognized. We hypothesize that this postoperative stiffness is more frequent than recognized and slows the primary postoperative healing after a rotator cuff reconstruction. We wondered how common is postoperative restriction of both active and passive range of motion after open rotator cuff repair in shoulders with free passive preoperative range of motion, how it recovers, and whether this condition influences short- and long-term results of surgery. We also explored factors predicting postoperative shoulder stiffness. We retrospectively identified 103 postoperative stiff shoulders among 416 consecutive open rotator cuff repairs, evaluating incidence and duration of stiffness, short-term clinical results and long-term range of motion, pain relief, shoulder strength, and functional results 3-20 (mean 8.7) years after surgery in 56 patients. The incidence of postoperative shoulder stiffness was 20%. It delayed primary postoperative healing by 3-6 months and resolved during a mean 6.3 months postoperatively. External rotation resolved first, corresponding to that of the controls at 3 months; flexion and abduction took less than 1 year after surgery. The mean summarized range of motion (flexion + abduction + external rotation) increased as high as 93% of the controls' range of motion by 6 months and 100% by 1 year. Flexion, abduction, and internal rotation improved to the level of the contralateral shoulders as did pain, strength, and function. Age at surgery and condition of the biceps tendon were related to postoperative stiffness. Postoperative stiff shoulder after open rotator cuff repair is a common complication resolving in 6-12 months with good long-term results. © The Finnish Surgical Society 2013.
Early versus delayed rehabilitation following arthroscopic rotator cuff repair: A systematic review.
Gallagher, Brian P; Bishop, Meghan E; Tjoumakaris, Fotios P; Freedman, Kevin B
2015-05-01
Early passive range of motion (ROM) following arthroscopic cuff repair is thought to decrease postoperative stiffness and improve functionality. However, early aggressive rehabilitation may compromise repair integrity. Our purpose was to perform a systematic review to determine if there are differences between early and delayed rehabilitation after arthroscopic rotator cuff repair in terms of clinical outcomes and healing. We performed a literature search with the terms 'arthroscopic rotator cuff', 'immobilization', 'early', 'delayed', 'late', and 'rehabilitation' using PubMed, Cochrane Central Register of Controlled Trials, and EMBASE. Selection criteria included: level I/II evidence ≤ 6 months in duration, comparing early versus delayed rehabilitation following arthroscopic repair. Data regarding demographics, sample sizes, duration, cuff pathology, surgery, rehabilitation, functional outcomes, pain, ROM and anatomic assessment of healing were analyzed. PRIMSA criteria were followed. We identified six articles matching our criteria. Three reported significantly increased functional scores within the first 3-6 months with early rehabilitation compared to the delayed group, only one of which continued to observe a difference at a final follow-up of 15 months. Four articles showed improved ROM in the first 3-6 months post-operatively with early rehabilitation. One noted transient differences in pain scores. Only one study noted significant differences in ROM at final follow-up. No study reported any significant difference in rates of rotator cuff re-tear. However, two studies noted a trend towards increased re-tear with early rehabilitation that did not reach significance. This was more pronounced in studies including medium-large tears. Early rehabilitation after arthroscopic cuff repair is associated with some initial improvements in ROM and function. Ultimately, similar clinical and anatomical outcomes between groups existed at 1 year. While there was no significant difference between groups in anatomic failure of the repaired cuff, there may be a trend towards increased re-tear with larger tears.
Updates of operative techniques for upper airway stimulation.
Heiser, Clemens; Thaler, Erica; Boon, Maurits; Soose, Ryan J; Woodson, B Tucker
2016-09-01
Selective upper airway stimulation has been established as an additional treatment for obstructive sleep apnea (OSA). Essential for the treatment is the precise placement of the cuff electrode for select branches of the hypoglossal nerve, which innervate the protrusors and stiffeners of the tongue. A direct approach to the distal hypoglossal nerve has been established to achieve this goal. For surgeons, detailed knowledge of this anatomy is vital. Another decisive step is the placement of the sensing lead between the intercostal muscles. Also, the complexity of follow-up care postoperatively should be kept in mind. The aim of this article is to provide the latest knowledge on the neuroanatomy of the hypoglossal nerve and to give surgeons a step-by-step guide on the current operative technique. Laryngoscope, 126:S12-S16, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Schiefer, Matthew; Gamble, Jenniffer; Strohl, Kingman Perkins
2018-06-07
Obstructive sleep apnea (OSA) is a disorder characterized by collapse of the velopharynx and/or oropharynx during sleep when drive to the upper airway is reduced. Here, we explore an indirect approach for activation of upper airway muscles which might affect airway dynamics- unilateral electrical stimulation of the afferent fibers of the sciatic nerve- in an anesthetized rabbit model. A nerve cuff electrode was placed around the sciatic and hypoglossal nerves to deliver stimulus while air flow, air pressure, and alae nasi electromyogram (EMG) were monitored both prior to and after sciatic transection. Sciatic nerve stimulation increased respiratory effort, rate, and alae nasi EMG, which persisted for seconds after stimulation; however, upper airway resistance was unchanged. Hypoglossal stimulation reduced resistance without altering drive. While sciatic nerve stimulation is not ideal for treating obstructive sleep apnea, it remains a target for altering respiratory drive.
Application of high-quality SiO2 grown by multipolar ECR source to Si/SiGe MISFET
NASA Technical Reports Server (NTRS)
Sung, K. T.; Li, W. Q.; Li, S. H.; Pang, S. W.; Bhattacharya, P. K.
1993-01-01
A 5 nm-thick SiO2 gate was grown on an Si(p+)/Si(0.8)Ge(0.2) modulation-doped heterostructure at 26 C with an oxygen plasma generated by a multipolar electron cyclotron resonance source. The ultrathin oxide has breakdown field above 12 MV/cm and fixed charge density about 3 x 10 exp 10/sq cm. Leakage current as low as 1/micro-A was obtained with the gate biased at 4 V. The MISFET with 0.25 x 25 sq m gate shows maximum drain current of 41.6 mA/mm and peak transconductance of 21 mS/mm.
Belichenko, P V; Leontovich, T A
1989-05-01
Giant multipolar neurons of nucleus reticularis gigantocellularis of rats which had been kept on board the biosatellite "Kosmos-1667" were morphometrically studied. There was a trend towards the increase in the cellular surface, the maximum diameter of dendritic field, the volume of the whole dendritic territory in the test group ad in the control experimental group kept on the earth. A reliable decrease in dendritic mass oriented to nucleus vestibularis and an increase in dendritic mass oriented to the midline were also found in test group, as compared to 3 control groups. Our data were discussed in the light of nervous tissue plasticity in adult mammals.
Redler, Lauren H.; Byram, Ian R.; Luchetti, Timothy J.; Tsui, Ying Lai; Moen, Todd C.; Gardner, Thomas R.; Ahmad, Christopher S.
2014-01-01
Background: Redundancies in the rotator cuff tissue, commonly referred to as “dog ear” deformities, are frequently encountered during rotator cuff repair. Knowledge of how these deformities are created and their impact on rotator cuff footprint restoration is limited. Purpose: The goals of this study were to assess the impact of tear size and repair method on the creation and management of dog ear deformities in a human cadaveric model. Study Design: Controlled laboratory study. Methods: Crescent-shaped tears were systematically created in the supraspinatus tendon of 7 cadaveric shoulders with increasing medial to lateral widths (0.5, 1.0, and 1.5 cm). Repair of the 1.5-cm tear was performed on each shoulder with 3 methods in a randomized order: suture bridge, double-row repair with 2-mm fiber tape, and fiber tape with peripheral No. 2 nonabsorbable looped sutures. Resulting dog ear deformities were injected with an acrylic resin mixture, digitized 3-dimensionally (3D), and photographed perpendicular to the footprint with calibration. The volume, height, and width of the rotator cuff tissue not in contact with the greater tuberosity footprint were calculated using the volume injected, 3D reconstructions, and calibrated photographs. Comparisons were made between tear size, dog ear measurement technique, and repair method utilizing 2-way analysis of variance and Student-Newman-Keuls multiple-comparison tests. Results: Utilizing 3D digitized and injection-derived volumes and dimensions, anterior dog ear volume, height, and width were significantly smaller for rotator cuff repair with peripheral looped sutures compared with a suture bridge (P < .05) or double-row repair with 2-mm fiber tape alone (P < .05). Similarly, posterior height and width were significantly smaller for repair with looped peripheral sutures compared with a suture bridge (P < .05). Dog ear volumes and heights trended larger for the 1.5-cm tear, but this was not statistically significant. Conclusion: When combined with a standard transosseous-equivalent repair technique, peripheral No. 2 nonabsorbable looped sutures significantly decreased the volume, height, and width of dog ear deformities, better restoring the anatomic footprint of the rotator cuff. Clinical Relevance: Dog ear deformities are commonly encountered during rotator cuff repair. Knowledge of a repair technique that reliably decreases their size, and thus increases contact at the anatomic footprint of the rotator cuff, will aid sports medicine surgeons in the management of these deformities. PMID:26535317
Incidence and treatment of postoperative stiffness following arthroscopic rotator cuff repair.
Huberty, David P; Schoolfield, John D; Brady, Paul C; Vadala, Antonio P; Arrigoni, Paolo; Burkhart, Stephen S
2009-08-01
The purpose of this study was to determine the incidence of clinically significant postoperative stiffness following arthroscopic rotator cuff repair. This study also sought to determine the clinical and surgical factors that were associated with higher rates of postoperative stiffness. Finally, we analyzed the result of arthroscopic lysis of adhesions and capsular release for treatment of patients who developed refractory postoperative stiffness 4 to 19 months (median, 8 months) following arthroscopic rotator cuff repair. A retrospective review of a consecutive series of arthroscopic rotator cuff repairs was conducted. During a 3-year time period, the senior author (S.S.B.) performed 489 arthroscopic rotator cuff repairs. The operative indications, technique of the rotator cuff repair, and the rehabilitation protocol were essentially unchanged during this time period. Demographic data, comorbid medical conditions, rotator cuff tear description, technique of repair, and concomitant surgical procedures were evaluated for their effect on stiffness. All office evaluations were reviewed to determine the pre- and postoperative motion, pain scores, functional strength, and patient satisfaction. Patients who were dissatisfied because of the development of postoperative stiffness underwent secondary arthroscopic lysis of adhesions. The final result of the secondary lysis of adhesions and capsular release were analyzed. In total, 24 patients (4.9%) were dissatisfied with the result of their procedure because of the development of postoperative stiffness, which was more likely (P < .05) to develop in patients with Workers' Compensation insurance (8.6%), patients younger than 50 years of age (8.6%), those with a coexisting diagnosis of calcific tendonitis (16.7%) or adhesive capsulitis (15.0%) requiring additional postoperative therapy, partial articular-sided tendon avulsion (PASTA) type rotator cuff tear (13.5%), or concomitant labral repair (11.0%). Patients with concomitant coracoplasty (2.3%) or tears larger in size and/or involving more tendons were less likely (P < .05) to develop postoperative stiffness. Among 90 patients positive for selected risk factors (adhesive capsulitis, excision of calcific deposits, single-tendon repair, PASTA repair, or any labral repair without a concomitant coracoplasty), 12 (13.3%) developed postoperative stiffness (P < .001). This overall clinical risk factor combined with Workers' Compensation insurance identified 16 of the 24 cases resulting in a sensitivity of 66.7% and a specificity of 64.5%. All 24 patients who experienced postoperative stiffness elected to undergo arthroscopic lysis of adhesions and capsular release, which was performed from 4 to 19 months (median, 8 months) after the rotator cuff repair. During second-look arthroscopy, 23 patients (95.8%) were noted to have complete healing of the original pathology. Following capsular release, all 24 patients were satisfied with the overall result of their treatment. In a series of 489 consecutive arthroscopic rotator cuff repairs, we found that 24 patients (4.9%) developed postoperative stiffness. Risk factors for postoperative stiffness were calcific tendinitis, adhesive capsulitis, single-tendon cuff repair, PASTA repair, being under 50 years of age, and having Workers' Compensation insurance. Twenty-three of 24 patients (95.8%) showed complete healing of the rotator cuff. Arthroscopic release resulted in normal motion in all cases. Level IV, therapeutic case series.
Crusher, R H
2000-07-01
Different types of rotator cuff injuries frequently present to Accident and Emergency departments and minor injury units but can be difficult to differentiate clinically. This brief case study describes the examination and diagnosis of related shoulder injuries, specifically rotator cuff tears/disruption and calcifying supraspinatus tendinitis. The relevant anatomy and current therapies for these injuries is also discussed to enable the emergency nurse practitioner to have a greater understanding of the theory surrounding their diagnosis and treatments.
Brand, Jefferson C
2016-04-01
Results from a recent investigation into the practice of greater tuberosity decortication before rotator cuff repair showed that decortication significantly reduced the ultimate failure load. Although the potential of greater tuberosity treatment for solving the rotator cuff healing quandary still exists, the biomechanics are clear, one should not decorticate the greater tuberosity to cancellous bone. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Physiotherapy assessment of patients with rotator cuff pathology
2014-01-01
Pathology of the rotator cuff and sub-acromial bursa are considered to be the main cause of shoulder pain and dysfunction. In the absence of trauma, conservative care, including physiotherapy is the primary treatment. This paper aims to present the key features of a physiotherapy assessment, excluding diagnostic tests for rotator cuff pathology. It describes and explores how assessment can be used to direct management options and develop a treatment plan. PMID:27582940
Backwards Fading to Speed Task Learning
2013-09-01
estimates.) Table 1 Finalized Task List Task Domain Task Name Knot Tying Hand Cuff Rappel First Aid Fracture Bleed Map Reading* Resection...materials used. Hand Cuff . There are 10 steps in this task. To complete this task, the learner must manipulate a short length of rope (e.g...Design for Experiment 1 – Step Fade Experiment 1 (Step Fade) Task Type: Knot Tying Task Type: First Aid Task Complexity: Low (1) Hand Cuff (10
Automated Control of Endotracheal Tube Cuff Pressure During Simulated Flight
2016-06-01
ventilator, while the other two devices are stand-alone products. The fourth group of ETTs had the cuff pressure measured by the respiratory ...Maquet, Rastatt, Germany). To simulate a clinical environment, each model was ventilated using ventilator settings of respiratory rate of 12...rapidly changes with descent to below 10 cmH2O, allowing fluid above the cuff to readily move into the lower respiratory tract. As with ascent
Tailoring dielectric resonator geometries for directional scattering and Huygens’ metasurfaces
Campione, Salvatore; Basilio, Lorena I.; Warne, Larry K.; ...
2015-01-28
In this paper we describe a methodology for tailoring the design of metamaterial dielectric resonators, which represent a promising path toward low-loss metamaterials at optical frequencies. We first describe a procedure to decompose the far field scattered by subwavelength resonators in terms of multipolar field components, providing explicit expressions for the multipolar far fields. We apply this formulation to confirm that an isolated high-permittivity dielectric cube resonator possesses frequency separated electric and magnetic dipole resonances, as well as a magnetic quadrupole resonance in close proximity to the electric dipole resonance. We then introduce multiple dielectric gaps to the resonator geometrymore » in a manner suggested by perturbation theory, and demonstrate the ability to overlap the electric and magnetic dipole resonances, thereby enabling directional scattering by satisfying the first Kerker condition. We further demonstrate the ability to push the quadrupole resonance away from the degenerate dipole resonances to achieve local behavior. These properties are confirmed through the multipolar expansion and show that the use of geometries suggested by perturbation theory is a viable route to achieve purely dipole resonances for metamaterial applications such as wave-front manipulation with Huygens’ metasurfaces. Our results are fully scalable across any frequency bands where high-permittivity dielectric materials are available, including microwave, THz, and infrared frequencies.« less
Anatomy of the binary black hole recoil: A multipolar analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schnittman, Jeremy D.; Buonanno, Alessandra; Meter, James R. van
2008-02-15
We present a multipolar analysis of the gravitational recoil computed in recent numerical simulations of binary black hole coalescence, for both unequal masses and nonzero, nonprecessing spins. We show that multipole moments up to and including l=4 are sufficient to accurately reproduce the final recoil velocity (within {approx_equal}2%) and that only a few dominant modes contribute significantly to it (within {approx_equal}5%). We describe how the relative amplitudes, and more importantly, the relative phases, of these few modes control the way in which the recoil builds up throughout the inspiral, merger, and ringdown phases. We also find that the numerical resultsmore » can be reproduced by an 'effective Newtonian' formula for the multipole moments obtained by replacing the radial separation in the Newtonian formulas with an effective radius computed from the numerical data. Beyond the merger, the numerical results are reproduced by a superposition of three Kerr quasinormal modes. Analytic formulas, obtained by expressing the multipole moments in terms of the fundamental quasinormal modes of a Kerr black hole, are able to explain the onset and amount of 'antikick' for each of the simulations. Lastly, we apply this multipolar analysis to help explain the remarkable difference between the amplitudes of planar and nonplanar kicks for equal-mass spinning black holes.« less
Anatomy of the Binary Black Hole Recoil: A Multipolar Analysis
NASA Technical Reports Server (NTRS)
Schnittman, Jeremy; Buonanno, Alessandra; vanMeter, James R.; Baker, John G.; Boggs, William D.; Centrella, Joan; Kelly, Bernard J.; McWilliams, Sean T.
2007-01-01
We present a multipolar analysis of the recoil velocity computed in recent numerical simulations of binary black hole coalescence, for both unequal masses and non-zero, non-precessing spins. We show that multipole moments up to and including 1 = 4 are sufficient to accurately reproduce the final recoil velocity (= 98%) and that only a few dominant modes contribute significantly to it (2 95%). We describe how the relative amplitude, and more importantly, the relative phase, of these few modes control the way in which the recoil builds up throughout the inspiral, merger, and ring-down phases. We also find that the numerical results can be reproduced, to a high level of accuracy, by an effective Newtonian formula for the multipole moments obtained by replacing in the Newtonian formula the radial separation with an effective radius computed from the numerical data. Beyond the merger, the numerical results are reproduced by a superposition of three Kerr quasi-normal modes. Analytic formulae, obtained by expressing the multipole moments in terms of the fundamental QNMs of a Kerr BH, are able to explain the onset and amount of '.anti-kick" for each of the simulations. Lastly, we apply this multipolar analysis to understand the remarkable difference between the amplitudes of planar and non-planar kicks for equal-mass spinning black holes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tretiak, Sergei
2009-01-01
The aim of the present work is to demonstrate that combined spectral tuning of fluorescence and two-photon absorption (TPA) properties of multipolar chromophores can be achieved by introduction of slight electronic chemical dissymmetry. In that perspective, two novel series of structurally related chromophores have been designed and studied: a first series based on rod-like quadrupolar chromophores bearing different electron-donating (D) end groups and a second series based on three-branched octupolar chromophores built from a trigonal donating moiety and bearing various acceptor (A) peripheral groups. The influence of the electronic dissymmetry is investigated by combined experimental and theoretical studies of themore » linear and nonlinear optical properties of dissymmetric chromophores compared to their symmetrical counterparts. In both types of systems (i.e. quadrupoles and octupoles) experiments and theory reveal that excitation is essentially delocalized and that excitation involves synchronized charge redistribution between the different D and A moieties within the multipolar structure (i.e. concerted intramolecular charge transfer). In contrast, the emission stems only from a particular dipolar subunit bearing the strongest D or A moieties due to fast excitation localization after excitation prior to emission. Hence control of emission characteristics (polarization and emission spectrum) in addition to localization can be achieved by controlled introduction of electronic dissymmetry (i.e. replacement of one of the D or A end-groups by a slightly stronger D{prime} or A{prime} units). Interestingly dissymmetrical functionalization of both quadrupolar and octupolar compounds does not lead to significant loss in TPA responses and can even be beneficial due to the spectral broadening and peak position tuning that it allows. This study thus reveals an original molecular engineering route strategy allowing major TPA enhancement in multipolar structures due to concerted multidimensional ICT while providing for spatial control of emission localization. Such route could be extended to more intricate (dendritic) and multipolar systems (3D).« less
NASA Astrophysics Data System (ADS)
Stanley, S.; Tian, B. Y.
2016-12-01
Previous dynamo scaling law studies (Christensen and Aubert, 2006) have demonstrated that the morphology of a planet's magnetic field is determined by the local Rossby number (Rol): a non-dimensional diagnostic variable that quantifies the ratio of inertial forces to Coriolis forces on the average length scale of the flow. Dynamos with Rol < 0.1 produce dipolar dominated magnetic fields whereas dynamos with Rol > 0.1 produce multipolar magnetic fields. Scaling studies have also determined the dependence of the local Rossby number on non-dimensional parameters governing the system - specifically the Ekman, Prandtl, magnetic Prandtl and flux-based Rayleigh numbers (Olson and Christensen, 2006). However, those studies focused on the specific convective shell thickness of the Earth's core and hence could not determine the influence of convective shell thickness on the local Rossby number. Aubert et al. (2009) investigated the role of convective shell thickness on dynamo scaling laws in order to investigate the palaeo-evolution of the geodynamo. Due to the focus of that study, they varied the ratio of the inner to outer core radii (rio) from 0 to 0.35 and found Rol scales with (1+rio). Here we consider a larger range of convective shell thicknesses and find an exponential dependence of rio on the local Rossby number. Our results are consistent with Aubert et al. (2009) for their small rio values. With this new scaling dependence on convective shell thickness, we find that Uranus and Neptune reside deeply in the multipolar regime, whereas without the dependence on rio, they resided near Rol =0.1; i.e. on the boundary between dipolar and multipolar fields and close to where Earth resides in the parameter space. We also find that Earth will reside more deeply in the multipolar regime, and hence not produce a stable dipolar field once the inner core has grown such that rio = 0.4.
Donohue, Kenneth W; Ricchetti, Eric T; Ho, Jason C; Iannotti, Joseph P
2018-03-07
Glenoid morphology and rotator cuff muscle quality are important anatomic factors that can impact longevity of the glenoid component following total shoulder arthroplasty (TSA). We hypothesized that rotator cuff muscle fatty infiltration is associated with increased pathologic glenoid bone loss in glenohumeral osteoarthritis (OA). We retrospectively reviewed 190 preoperative computed tomography (CT) scans of 175 patients (mean age, 66 years; range, 44 to 90 years) who underwent TSA for the treatment of primary glenohumeral OA. Two-dimensional orthogonal CT images were reformatted in the plane of the scapula from 3-dimensional images. Pathologic joint-line medialization was defined with use of the glenoid vault model. Pathologic glenoid version was measured directly. Glenoid morphology was graded according to a modified Walch classification (subtypes A1, A2, B1, B2, B3, C1, and C2). Rotator cuff muscle fatty infiltration was assessed and assigned a Goutallier score on the sagittal CT slice just medial to the spinoglenoid notch for each muscle. There was a significant difference in the Goutallier score for the supraspinatus, infraspinatus, and teres minor muscles between Walch subtypes (p ≤ 0.05). High-grade posterior rotator cuff muscle fatty infiltration was present in 55% (21) of 38 B3 glenoids compared with 8% (3) of 39 A1 glenoids. Increasing joint-line medialization was associated with increasing fatty infiltration of all rotator cuff muscles (p ≤ 0.05). Higher fatty infiltration of the infraspinatus, teres minor, and combined posterior rotator cuff muscles was associated with increasing glenoid retroversion (p ≤ 0.05). After controlling for joint-line medialization and retroversion, B3 glenoids were more likely to have fatty infiltration of the supraspinatus and infraspinatus muscles than B2 glenoids were. High-grade rotator cuff muscle fatty infiltration is associated with B3 glenoids, increased pathologic glenoid retroversion, and increased joint-line medialization. Additional studies are needed to determine the causal relationship between these muscle changes and glenoid wear, whether these muscle changes independently affect clinical and radiographic outcomes in anatomic TSA, and whether fatty infiltration can improve postoperatively with correction of pathologic version and/or joint-line restoration. This study investigates the association between different patterns of glenoid bone loss and rotator cuff muscle fatty infiltration. Both factors have been shown to affect clinical outcome following TSA.
Yeo, Daniel Y T; Walton, Judie R; Lam, Patrick; Murrell, George A C
2017-03-01
Rotator cuff repair often results in significant pain postoperatively, the cause of which is undetermined. Purpose/Hypothesis: The aim of this study was to evaluate the relationship between rotator cuff tear area and postoperative pain in patients who had undergone arthroscopic rotator cuff repair. We hypothesized that larger tears would be more painful because of elevated repair tension at 1 week postoperatively but that smaller tears would be more painful because of a greater healing response, especially from 6 weeks postoperatively. Cohort study; Level of evidence, 3. A total of 1624 patients who underwent arthroscopic rotator cuff repair were included in this study. Exclusion criteria were moderate to severe osteoarthritis, isolated subscapularis repair, calcific tendinitis, synthetic patch repair, revision surgery, and retears on ultrasound at 6 months after surgery. Rotator cuff tears were subdivided into groups based on the tear size and retear rate found for each group. A modified L'Insalata questionnaire was given before surgery and at 1 week, 6 weeks, 3 months, and 6 months after surgery. Pearson and Spearman correlation coefficient tests were performed between rotator cuff tear areas and pain scores. Intraoperative rotator cuff tear areas did not correlate with pain scores preoperatively or at 1 week after surgery. A smaller tear area was associated with more frequent and severe pain with overhead activities, at rest, and during sleep as well as a poorer perceived overall shoulder condition at 6 weeks, 3 months, and 6 months after repair ( r = 0.11-0.23, P < .0001). Patients who were younger, had partial-thickness tears, and had occupational injuries experienced more pain postoperatively ( r = 0.10-0.28, P < .0001). Larger tears did not have more pain at 1 week after surgery. The retear rate was 7% in tears <2 cm 2 but reached 44% in tears >8 cm 2 . There were fewer retears with smaller tears, but they were more painful than large tears postoperatively from 6 weeks to 6 months after surgery. Smaller tears may heal more vigorously, causing more pain. Patients with smaller tears experienced more pain after rotator cuff repair compared with patients with larger tears. These findings are contrary to previous ideas about tear size and postoperative pain. Healing is likely a determinant of postoperative pain.
A systematic review of cost-effective treatment of postoperative rotator cuff repairs.
Dickinson, Rebecca N; Kuhn, John E; Bergner, Jamie L; Rizzone, Katherine H
2017-05-01
The Bundled Payments for Care Improvement initiative combines payment of multiple services for episodes of care into 1 bundle. Rotator cuff repair is a likely candidate for future inclusion. The objective of this study was to determine cost-effective, high-quality postoperative rehabilitation dosing and cryotherapy for patients undergoing rotator cuff repair based on systematic review of the literature. Systematic review of level I and level II articles was performed in PubMed, Cochrane Databases, and PEDro. Conference references and bibliographies were also reviewed. For postoperative therapy, keywords included rotator cuff, rotator cuff repair, exercise therapy, exercise, unsupervised, self-care, postoperative period, physical therapy, and physiotherapy; for cryotherapy, keywords included rotator cuff repair, shoulder, cryotherapy, and ice. Five studies compared postoperative outcomes in participants assigned to supervised therapy vs. unsupervised therapy. Three found no difference between groups. One found improved outcomes in supervised therapy. Limitations included that therapies were not consistently defined and significant methodologic issues were present, decreasing the applicability and validity of the results. Five articles examined cryotherapy outcomes in the postoperative shoulder. Two studies showed improved patient outcomes with cryotherapy vs. no cryotherapy; 2 studies showed no decrease in joint space temperatures at 90 minutes but decrease in temperature at 4 to 23 hours postoperatively. One study indicated that an ice bag and Ace bandage might be as effective as continuous, compressive cryotherapy units using patient-reported outcomes. Further studies are needed to determine effective dosing of physical therapy after rotator cuff repair. Cryotherapy is favorable and cost-effective using simple methods for delivery. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
T lymphocytes are not required for the development of fatty degeneration after rotator cuff tear
Gumucio, J.; Flood, M.; Harning, J.; Phan, A.; Roche, S.; Lynch, E.; Bedi, A.; Mendias, C.
2014-01-01
Objectives Rotator cuff tears are among the most common and debilitating upper extremity injuries. Chronic cuff tears result in atrophy and an infiltration of fat into the muscle, a condition commonly referred to as ‘fatty degeneration’. While stem cell therapies hold promise for the treatment of cuff tears, a suitable immunodeficient animal model that could be used to study human or other xenograft-based therapies for the treatment of rotator cuff injuries had not previously been identified. Methods A full-thickness, massive supraspinatus and infraspinatus tear was induced in adult T-cell deficient rats. We hypothesised that, compared with controls, 28 days after inducing a tear we would observe a decrease in muscle force production, an accumulation of type IIB fibres, and an upregulation in the expression of genes involved with muscle atrophy, fibrosis and inflammation. Results Chronic cuff tears in nude rats resulted in a 30% to 40% decrease in muscle mass, a 23% reduction in production of muscle force, and an induction of genes that regulate atrophy, fibrosis, lipid accumulation, inflammation and macrophage recruitment. Marked large lipid droplet accumulation was also present. Conclusions The extent of degenerative changes in nude rats was similar to what was observed in T-cell competent rats. T cells may not play an important role in regulating muscle degeneration following chronic muscle unloading. The general similarities between nude and T-cell competent rats suggest the nude rat is likely an appropriate preclinical model for the study of xenografts that have the potential to enhance the treatment of chronically torn rotator cuff muscles. Cite this article: Bone Joint Res 2014;3:262–72. PMID:25185444
Jaillette, Emmanuelle; Brunin, Guillaume; Girault, Christophe; Zerimech, Farid; Chiche, Arnaud; Broucqsault-Dedrie, Céline; Fayolle, Cyril; Minacori, Franck; Alves, Isabelle; Barrailler, Stephanie; Robriquet, Laurent; Tamion, Fabienne; Delaporte, Emmanuel; Thellier, Damien; Delcourte, Claire; Duhamel, Alain; Nseir, Saad
2015-09-25
Ventilator-associated pneumonia (VAP) is the most common infection in intubated critically ill patients. Microaspiration of the contaminated gastric and oropharyngeal secretions is the main mechanism involved in the pathophysiology of VAP. Tracheal cuff plays an important role in stopping the progression of contaminated secretions into the lower respiratory tract. Previous in vitro studies suggested that conical cuff shape might be helpful in improving tracheal sealing. However, clinical studies found conflicting results. The aim of this study is to determine the impact of conical tracheal cuff shape on the microaspiration of gastric contents in critically ill patients. This prospective cluster randomized controlled crossover open-label trial is currently being conducted in ten French intensive care units (ICUs). Patients are allocated to intubation with a polyvinyl chloride (PVC) standard (barrel)-shaped or a PVC conical-shaped tracheal tube. The primary objective is to determine the impact of the conical shaped tracheal cuff on abundant microaspiration of gastric contents. Secondary outcomes include the incidence of microaspiration of oropharyngeal secretions, tracheobronchial colonization, VAP and ventilator-associated events. Abundant microaspiration is defined as the presence of pepsin at significant level (>200 ng/ml) in at least 30 % of the tracheal aspirates. Pepsin and amylase are quantitatively measured in all tracheal aspirates during the 48 h following inclusion. Quantitative tracheal aspirate culture is performed at inclusion and twice weekly. We plan to recruit 312 patients in the participating ICUs. BEST Cuff is the first randomized controlled study evaluating the impact of PVC tracheal-cuff shape on gastric microaspirations in patients receiving invasive mechanical ventilation. Enrollment began in June 2014 and is expected to end in October 2015. ClinicalTrials.gov Identifier: NCT01948635 (registered 31 August 2013).
Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.
Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus
2011-01-01
Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P < .001) from the preset level. Fluid aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P < .001) and was much more during 15 and 20 seconds suction time as compared to 5 seconds (P < .001). Massive aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.
The Relationship Between Body Mass Index and Fatty Infiltration in the Shoulder Musculature.
Dow, David F; Mehta, Kaushal; Xu, Yuanfang; England, Eric
Fatty infiltration in the rotator cuff muscles has been well studied in the setting of rotator cuff tendon tears to help predict outcomes of surgical repair. Fatty infiltration in the rotator cuff has also been independently correlated to the variables of age and sex. The purpose of our study was to determine if there is a relationship between body mass index and fatty infiltration in patients with no imaging evidence of rotator cuff tendinosis or tear. Radiology reports of all magnetic resonance imaging examinations of the shoulder were searched over a 2-year period. Studies with imaging findings of rotator cuff tendinosis, partial tear, or full thickness tear were excluded from the study, resulting in a total of 143 patients with normal rotator cuffs who were included in the study. These studies were reviewed by consensus by 2 fellowship-trained musculoskeletal radiologists who used the Goutallier 5-stage scoring system to grade the supraspinatus, infraspinatus, subscapularis, teres minor, teres major, and deltoid muscles. Sex was shown not to be significantly associated with fatty infiltration with the exception of the deltoid muscle, which showed a statistically significant increase in fatty infiltration associated with female sex (P = 0.038). Age was shown to be a statistically significant predictor of fatty infiltration for all 6 muscles (P < 0.05). Body mass index was shown to be a statistically significant predictor of fatty infiltration for all of the evaluated shoulder musculature (P < 0.05) with the exception of the teres minor. Our results suggest that increased body mass index is associated with increased fatty infiltration in the supraspinatus, infraspinatus, subscapularis, teres major, and deltoid muscles. This relationship could help guide the decisions of orthopedic surgeons when considering rotator cuff repair.
Incidence of retear with double-row versus single-row rotator cuff repair.
Shen, Chong; Tang, Zhi-Hong; Hu, Jun-Zu; Zou, Guo-Yao; Xiao, Rong-Chi
2014-11-01
Rotator cuff tears have a high recurrence rate, even after arthroscopic rotator cuff repair. Although some biomechanical evidence suggests the superiority of the double-row vs the single-row technique, clinical findings regarding these methods have been controversial. The purpose of this study was to determine whether the double-row repair method results in a lower incidence of recurrent tearing compared with the single-row method. Electronic databases were systematically searched to identify reports of randomized, controlled trials (RCTs) comparing single-row with double-row rotator cuff repair. The primary outcome assessed was retear of the repaired cuff. Secondary outcome measures were the American Shoulder and Elbow Surgeons (ASES) shoulder score, the Constant shoulder score, and the University of California, Los Angeles (UCLA) score. Heterogeneity between the included studies was assessed. Six studies involving 428 patients were included in the review. Compared with single-row repair, double-row repair demonstrated a lower retear incidence (risk ratio [RR]=1.71 [95% confidence interval (CI), 1.18-2.49]; P=.005; I(2)=0%) and a reduced incidence of partial-thickness retears (RR=2.16 [95% CI, 1.26-3.71]; P=.005; I(2)=26%). Functional ASES, Constant, and UCLA scores showed no difference between single- and double-row cuff repairs. Use of the double-row technique decreased the incidence of retears, especially partial-thickness retears, compared with the single-row technique. The functional outcome was not significantly different between the 2 techniques. To improve the structural outcome of the repaired rotator cuff, surgeons should use the double-row technique. However, further long-term RCTs on this topic are needed. Copyright 2014, SLACK Incorporated.
Kim, Min-Soo; Lee, Jeong-Rim; Shin, Yang-Sik; Chung, Ji-Won; Lee, Kyu-Ho; Ahn, Ki Ryang
2014-03-01
This single-center, prospective, randomized, double-blind, 2-arm, parallel group comparison trial was performed to establish whether the adult-sized laryngeal mask airway (LMA) Classic (The Laryngeal Mask Company Ltd, Henley-on-Thames, UK) could be used safely without any consideration of cuff hyperinflation when a cuff of the LMA Classic was inflated using half the maximum inflation volume or the resting volume before insertion of device. Eighty patients aged 20 to 70 years scheduled for general anesthesia using the LMA Classic were included. Before insertion, the cuff was partially filled with half the maximum inflation volume in the half volume group or the resting volume created by opening the pilot balloon valve to equalize with atmospheric pressure in the resting volume group. Several parameters regarding insertion, intracuff pressure, airway leak pressure, and leakage volume/fraction were collected after LMA insertion. The LMA Classic with a partially inflated cuff was successfully inserted in all enrolled patients. Both groups had the same success rate of 95% at the first insertion attempt. The half volume group had a lower mean intracuff pressure compared with the resting volume group (54.5 ± 16.1 cm H2O vs 61.8 ± 16.1 cm H2O; P = .047). There was no difference in airway leak pressure or leakage volume/fraction between the 2 groups under mechanical ventilation. The partially inflated cuff method using half the maximum recommended inflation volume or the resting volume is feasible with the adult-sized LMA Classic, resulting in a high success rate of insertion and adequate range of intracuff pressures. Copyright © 2014 Elsevier Inc. All rights reserved.
Walter, S G; Stadler, T; Thomas, T S; Thomas, W
2018-03-02
To introduce a (semi-)quantitative surgical score for the classification of rotator cuff tears. A total of 146 consecutive patients underwent rotator cuff repair and were assessed using the previously defined Advanced Rotator Cuff Tear Score (ARoCuS) criteria: muscle tendon, size, tissue quality, pattern as well as mobilization of the tear. The data set was split into a training (125 patients) and a testing set (21 patients). The training data set fitted a nonlinear predictive model of the tear score based on the ARoCuS criteria, while the testing data served as control. Based on the scoring results, rotator cuff tears were assigned to one of four categories (ΔV I-IV) and received a stage-adapted treatment. For statistical analysis, mean values ± standard deviation, interclass correlation coefficients (ICC) and kappa values were calculated. Overall, 32 patients were classified as ΔV I, 68 as ΔV II and 37 as ΔV III. Nine patients showed ΔV IV tears. Patients of all ΔV groups improved significantly their Constant scores (p < 0.001) and profited from significant pain reduction after surgery (p < 0.001). To date, ten patients have undergone revision surgery with five of them primarily classified as ΔV IV. Kappa values for the interobserver reliability ranged between 0.69 and 0.95. ICC scores for the ΔV category were 0.95 for interobserver reliability. The ARoCuS facilitates intra-operative decision-making and enables surgeons and researches to document rotator cuff tears in a standardized and reproducible manner.
Dejaco, Beate; Habets, Bas; van Loon, Corné; van Grinsven, Susan; van Cingel, Robert
2017-07-01
To investigate the effectiveness of isolated eccentric versus conventional exercise therapy in patients with rotator cuff tendinopathy. Thirty-six patients with rotator cuff tendinopathy, diagnosed by an orthopaedic surgeon, were included and randomly allocated to an isolated eccentric exercise (EE) group (n = 20, mean age = 50.2 ± 10.8 years) or a conventional exercise (CG) group (n = 16, mean age = 48.6 ± 12.3 years). Both groups fulfilled a 12-week daily home-based exercise programme and received a total amount of nine treatment sessions. The Constant Murley score was used to evaluate both objective (e.g. range of motion and strength) and subjective measures (e.g. pain and activities of daily living). A visual analogue scale (VAS) was used to evaluate pain during daily activities. As secondary outcomes, shoulder range of motion and isometric abduction strength in 45° in the scapular plane were evaluated. All measurements were taken at baseline, at 6, 12 and 26 weeks. After 26 weeks, both groups showed a significant increase in the Constant Murley score and a significant decrease in VAS scores. No difference was found between the groups, for any of the evaluated outcome measures. A 12-week-isolated eccentric training programme of the rotator cuff is beneficial for shoulder function and pain after 26 weeks in patients with rotator cuff tendinopathy. However, it is no more beneficial than a conventional exercise programme for the rotator cuff and scapular muscles. Based on the results, clinicians should take into account that performing two eccentric exercises twice a day is as effective as performing six concentric/eccentric exercises once a day in patients with rotator cuff tendinopathy.
Arthroscopic rotator cuff repair in the weight-bearing shoulder.
Kerr, Jacek; Borbas, Paul; Meyer, Dominik C; Gerber, Christian; Buitrago Téllez, Carlos; Wieser, Karl
2015-12-01
In wheelchair-dependent individuals, pain often develops because of rotator cuff tendon failure and/or osteoarthritis of the glenohumeral joint. The purposes of this study were to investigate (1) specific rotator cuff tear patterns, (2) structural healing, and (3) clinical outcomes after arthroscopic rotator cuff repair in a cohort of wheelchair-dependent patients. Forty-six shoulders with a mean follow-up of 46 months (range, 24-82 months; SD, 13 months) from a consecutive series of 61 shoulders in 56 patients (46 men and 10 women) undergoing arthroscopic rotator cuff repair were available for analysis. Clinical outcome analysis was performed using the Constant-Murley score, the Subjective Shoulder Value, and the American Shoulder and Elbow Surgeons score. The integrity of the repair was analyzed by ultrasound. Of the shoulders, 87% had supraspinatus involvement, 70% had subscapularis involvement, and 57% had an anterosuperior lesion involving both the supraspinatus and subscapularis. Despite an overall structural failure rate of 33%, the patients showed improvements in the Constant-Murley score from 50 points (range, 22-86 points; SD, 16 points) preoperatively to 80 points (range, 40-98 points; SD, 12 points) postoperatively and in the American Shoulder and Elbow Surgeons score from 56 points (range, 20-92 points; SD, 20 points) preoperatively to 92 points (range, 53-100 points; SD, 10 points) postoperatively, with a mean postoperative Subjective Shoulder Value of 84% (range, 25%-100%; SD, 17%). Failure of the rotator cuff in weight-bearing shoulders occurs primarily anterosuperiorly. Arthroscopic rotator cuff repair leads to a structural failure rate of 33% but satisfactory functional results with high patient satisfaction at midterm follow-up. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Koike, Yoichi; Sano, Hirotaka; Kita, Atushi; Itoi, Eiji
2013-09-01
Some patients with rotator cuff tears complain of pain, whereas others are asymptomatic. Previous studies have pointed out the presence of active bone metabolism in the painful shoulder, identified with increased radioisotope uptake during bone scintigraphy. Shoulders with symptomatic rotator cuff tears will demonstrate higher radioisotope uptake than shoulders with asymptomatic tears with bone scintigraphy, reflecting active bone metabolism in symptomatic tears. Cross-sectional study; Level of evidence, 3. The study consisted of 3 groups: patients with symptomatic tears (symptomatic group), patients with asymptomatic tears (asymptomatic group), and controls (no tear group). The symptomatic group consisted of 28 shoulders from 28 patients with symptomatic rotator cuff tears (pain score ≤4 on the University of California, Los Angeles [UCLA] shoulder evaluation form) who underwent bone scintigraphy followed by rotator cuff repair. Of 70 volunteers who had previously undergone bone scintigraphy for diseases unrelated to their shoulder, 34 were selected for the asymptomatic group (pain score ≥8 on the UCLA shoulder form), and 32 were selected for the no tear group. The mean radioisotope uptake in the symptomatic group was significantly higher than that in the asymptomatic group (P = .02) and the no tear group (P = .02). Ten of 28 shoulders (36%) in the symptomatic group showed increased radioisotope uptake exceeding 2 standard deviations from the mean of the no tear group. This percentage was significantly higher when compared with the asymptomatic group (0%) (P < .01). Shoulders with a symptomatic rotator cuff tear showed higher radioisotope uptake on bone scintigraphy than those with an asymptomatic tear. The radioisotope uptake in shoulders with an asymptomatic tear was comparable with that in shoulders without a tear. Positive radioisotope uptake may be associated with pain in a subgroup of patients with rotator cuff tears.
Comorbidities in rotator cuff disease: a case-control study.
Titchener, Andrew G; White, Jonathan J E; Hinchliffe, Sally R; Tambe, Amol A; Hubbard, Richard B; Clark, David I
2014-09-01
Rotator cuff disease is a common condition in the general population, but relatively little is known about its associated risk factors. We have undertaken a large case-control study using The Health Improvement Network database to assess and to quantify the relative contributions of some constitutional and environmental risk factors for rotator cuff disease in the community. Our data set included 5000 patients with rotator cuff disease who were individually matched with a single control by age, sex, and general practice (primary care practice). The median age at diagnosis was 55 years (interquartile range, 44-65 years). Multivariate analysis showed that the risk factors associated with rotator cuff disease were Achilles tendinitis (odds ratio [OR] = 1.78), trigger finger (OR = 1.99), lateral epicondylitis (OR = 1.71), and carpal tunnel syndrome (OR = 1.55). Oral corticosteroid therapy (OR = 2.03), oral antidiabetic use (OR = 1.66), insulin use (OR = 1.77), and "overweight" body mass index of 25.1 to 30 (OR = 1.15) were also significantly associated. Current or previous smoking history, body mass index of greater than 30, any alcohol intake, medial epicondylitis, de Quervain syndrome, cubital tunnel syndrome, and rheumatoid arthritis were not found to be associated with rotator cuff disease. We have identified a number of comorbidities and risk factors for rotator cuff disease. These include lateral epicondylitis, carpal tunnel syndrome, trigger finger, Achilles tendinitis, oral corticosteroid use, and diabetes mellitus. The findings should alert the clinician to comorbid pathologic processes and guide future research into the etiology of this condition. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Black, Eric M; Austin, Luke S; Narzikul, Alexa; Seidl, Adam J; Martens, Kelly; Lazarus, Mark D
2016-09-01
We investigated the cost savings associated with arthroscopic transosseous (anchorless) double-row rotator cuff repair compared with double-row anchored (transosseous-equivalent [TOE]) repair. All patients undergoing double-row arthroscopic rotator cuff repair from 2009 to 2012 by a single surgeon were eligible for inclusion. The study included 2 consecutive series of patients undergoing anchorless or TOE repair. Excluded from the study were revision repairs, subscapularis repairs, patients with poor tendon quality or excursion requiring medialized repair, and partial repairs. Rotator cuff implant costs (paid by the institution) and surgical times were compared between the 2 groups, controlling for rotator cuff tear size and additional procedures performed. The study included 344 patients, 178 with TOE repairs and 166 with anchorless repairs. Average implant cost for TOE repairs was $1014.10 ($813.00 for small, $946.67 for medium, $1104.56 for large, and $1507.29 for massive tears). This was significantly more expensive compared with anchorless repairs, which averaged $678.05 ($659.75 for small, $671.39 for medium, $695.55 for large, and $716.00 for massive tears). Average total operative time in TOE and anchorless groups was not significantly different (99 vs. 98 minutes). There was larger (although not statistically significant) case time variation in the TOE group. Compared with TOE repair, anchorless rotator cuff repair provides substantial implant-related cost savings, with no significant differences in surgical time for medium and large rotator cuff tears. Case time for TOE repair varied more with extremes in tear size. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Rotator cuff tear and sarcopenia: are these related?
Chung, Seok Won; Yoon, Jong Pil; Oh, Kyung-Soo; Kim, Hyung Sup; Kim, Young Gun; Lee, Hyun-Joo; Jeong, Won-Ju; Kim, Dong-Hyun; Lee, Jong Soo; Yoon, Jee Wook
2016-09-01
Sarcopenia is the loss of muscle mass and consequent loss of muscle function with aging. Its prevalence among the general population is 12% to 30% in those aged >60 years. We evaluated (1) the difference in the prevalence of sarcopenia between patients with rotator cuff tear and controls and (2) the sarcopenia severity according to the size of the rotator cuff tear. Group 1 included 48 consecutive patients with chronic symptomatic full-thickness rotator cuff tears (mean age, 60.1 ± 6.5 years; range, 46-76 years), and group 2 included 48 age- and sex-matched patients. The sarcopenic index was evaluated by using the grip strength of the asymptomatic contralateral side and the skeletal muscle mass. No significant differences were found in the baseline data and demographic factors between the groups. The sarcopenic index was significantly inferior in the rotator cuff tear group than in the age- and sex-matched control groups (P = .041, .007, and .05, respectively). Patients with large to massive tears had a significantly inferior sarcopenic index than those with small and medium tears. The results showed that sarcopenia was more severe in patients with a chronic symptomatic full-thickness rotator cuff tear than in the age- and sex-matched control population and was correlated with the size of the tear, with the numbers available. Despite the individual variance in the underlying medical condition and physical activities, this study suggests that clinicians should consider the sarcopenic condition of patients with a rotator cuff tear, especially in elderly patients with large to massive tears. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Rotator cuff repair using cell sheets derived from human rotator cuff in a rat model.
Harada, Yoshifumi; Mifune, Yutaka; Inui, Atsuyuki; Sakata, Ryosuke; Muto, Tomoyuki; Takase, Fumiaki; Ueda, Yasuhiro; Kataoka, Takeshi; Kokubu, Takeshi; Kuroda, Ryosuke; Kurosaka, Masahiro
2017-02-01
To achieve biological regeneration of tendon-bone junctions, cell sheets of human rotator-cuff derived cells were used in a rat rotator cuff injury model. Human rotator-cuff derived cells were isolated, and cell sheets were made using temperature-responsive culture plates. Infraspinatus tendons in immunodeficient rats were resected bilaterally at the enthesis. In right shoulders, infraspinatus tendons were repaired by the transosseous method and covered with the cell sheet (sheet group), whereas the left infraspinatus tendons were repaired in the same way without the cell sheet (control group). Histological examinations (safranin-O and fast green staining, isolectin B4, type II collagen, and human-specific CD31) and mRNA expression (vascular endothelial growth factor; VEGF, type II collagen; Col2, and tenomodulin; TeM) were analyzed 4 weeks after surgery. Biomechanical tests were performed at 8 weeks. In the sheet group, proteoglycan at the enthesis with more type II collagen and isolectin B4 positive cells were seen compared with in the control group. Human specific CD31-positive cells were detected only in the sheet group. VEGF and Col2 gene expressions were higher and TeM gene expression was lower in the sheet group than in the control group. In mechanical testing, the sheet group showed a significantly higher ultimate failure load than the control group at 8 weeks. Our results indicated that the rotator-cuff derived cell sheet could promote cartilage regeneration and angiogenesis at the enthesis, with superior mechanical strength compared with the control. Treatment for rotator cuff injury using cell sheets could be a promising strategy for enthesis of tendon tissue engineering. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:289-296, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Functional outcomes after bilateral arthroscopic rotator cuff repair.
Aleem, Alexander W; Syed, Usman Ali M; Wascher, Jocelyn; Zoga, Adam C; Close, Koby; Abboud, Joseph A; Cohen, Steven B
2016-10-01
Arthroscopic repair of rotator cuff tears is a common procedure performed by orthopedic surgeons. There is a well-known incidence of up to 35% of bilateral rotator cuff tear disease in patients who have a known unilateral tear. The majority of the literature focuses on outcomes after unilateral surgery. The purpose of this study was to determine if there are clinical differences in shoulders of patients who underwent staged bilateral rotator cuff repairs during their lifetime. A retrospective review of all patients who underwent staged bilateral arthroscopic rotator cuff surgery at our institution was performed. All patients had at least 2 years of follow-up. Clinical outcome scores including the American Shoulder and Elbow Surgeons (ASES), Single Assessment Numeric Evaluation, and Rowe measures were obtained. A subset of patients returned for clinical and ultrasound evaluation performed by an independent fellowship-trained musculoskeletal radiologist. Overall, 110 shoulders in 55 patients, representing 68% of all eligible patients, participated. No clinical or statistical difference was found in any outcome measure. ASES scores averaged 86.5 (36.7-100) in the dominant shoulder compared with 89.6 (23.3-100) in the nondominant shoulder (P = .42). Ultrasound was available on 34 shoulders and showed complete healing rate of 88%. The shoulders with retearing of the rotator cuff (12%) demonstrated clinically relevant lower ASES scores (72.5) compared with shoulders with confirmed healed repairs (86.2; P = .2). Patients who undergo staged bilateral rotator cuff repair can expect to have similarly good clinical outcomes regardless of hand dominance or chronologic incidence with excellent healing rates in both shoulders. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Proctor, Christopher S
2014-10-01
Rotator cuff repair is a procedure with varying outcomes, and there has been subsequent interest in devices that reinforce the repair and enhance structural and functional outcomes. The objective of this study was to determine these outcomes for arthroscopic repair of large and massive rotator cuff tears augmented with a synthetic absorbable mesh designed specifically for reinforcement of tendon repair by imaging and clinical assessments. Consecutive arthroscopic repairs were performed on 18 patients with large to massive rotator cuff tears by use of a poly-l-lactic acid synthetic patch as a reinforcement device and fixation with 4 sutures. Patients were assessed preoperatively and at 6 months, 12 months, and a mean of 42 months after surgery by the American Shoulder and Elbow Surgeons (ASES) shoulder score to evaluate clinical performance and at 12 months by ultrasound to assess structural repair. Ultrasound showed that 15 of 18 patients had intact rotator cuff repair at 12 months; at 42 months, an additional patient had a failed repair. Patients showed improvement in the ASES shoulder score from 25 preoperatively to 71 at 12 months and 70 at 42 months after surgery. Patients with intact rotator cuff (n = 14) at 42 months had an ASES shoulder score of 82. The poly-l-lactic acid bioabsorbable patch designed specifically to reinforce the surgical repair of tendons supported successful repair of large to massive rotator cuff tears in 83% of patients at 12 months after surgery and 78% of patients at 42 months after surgery, with substantial functional improvement. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
The greater tuberosity angle: a new predictor for rotator cuff tear.
Cunningham, Gregory; Nicodème-Paulin, Emilie; Smith, Margaret M; Holzer, Nicolas; Cass, Benjamin; Young, Allan A
2018-04-24
The implication of scapular morphology in rotator cuff tears has been extensively studied. However, the role of the greater tuberosity (GT) should be of equal importance. The aim of this study was to propose a new radiographic marker, the GT angle (GTA), which measures the position of the GT in relation to the center of rotation of the humeral head. The hypothesis was that a higher angle value would be associated with a higher likelihood in detecting a rotator cuff tear. During 1 year, patients were prospectively recruited from a single institution specialized shoulder clinic in 2 different groups. The patient group consisted of individuals with a degenerative rotator cuff tear involving at least the supraspinatus. The control group consisted of individuals with no rotator cuff pathology. Individuals in both groups with congenital, post-traumatic, or degenerative alterations of the proximal humerus were excluded. The GTA was measured on an anteroposterior shoulder x-ray image with the arm in neutral rotation by 3 observers at 2 different times. The study recruited 71 patients (33 patients, 38 controls). Mean GTA value was 72.5° (range, 67.6°-79.2°) in patients and 65.2° (range, 55.8°-70.5°) for controls (P <.001). A value above 70° resulted in 93-fold higher odds of detecting a rotator cuff tear (P <.001). Interobserver and intraobserver reliability were high. GT morphology is implicated in rotator cuff tears. The GTA is a reliable radiographic marker, with more than 70° being highly predictive in detecting such lesions. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
Genetic and familial predisposition to rotator cuff disease: a systematic review.
Dabija, Dominique I; Gao, Chan; Edwards, Todd L; Kuhn, John E; Jain, Nitin B
2017-06-01
Rotator cuff disease is a common disorder leading to shoulder pain and loss of function. Its etiology in atraumatic cases is uncertain and is likely to extend beyond repetitive microtrauma or overuse. Our objective was to determine whether there is a genetic or familial predisposition to rotator cuff disease. A literature search of PubMed and Embase databases identified 251 citations. After review of the titles, abstracts, and full articles, 7 met our inclusion and exclusion criteria. Four studies assessed familial predisposition to rotator cuff disease. One of these demonstrated that siblings of an individual with a rotator cuff tear were more likely to develop a full-thickness tear and more likely to be symptomatic. A 5-year follow-up showed that the relative risks were increased for the siblings to have a full-thickness tear, for a tear to progress in size, and for being symptomatic. Another study demonstrated that a significantly higher number of individuals with tears had family members with a history of tears or surgery than those without tears did. The other 3 studies investigated whether a genetic predisposition to rotator cuff disease exists and found significant association of haplotypes in DEFB1, FGFR1, FGF3, ESRRB, and FGF10 and 2 single-nucleotide polymorphisms within SAP30BP and SASH1. Prior studies provide preliminary evidence for genetic and familial predisposition to rotator cuff disease. However, there is a lack of large genome-wide studies that can provide more definitive information and guide early detection of individuals at risk, prophylactic rehabilitation, and potential gene therapies and regenerative medicine interventions. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Genetic and Familial Predisposition to Rotator Cuff Disease: A Systematic Review
Dabija, Dominique I.; Gao, Chan; Edwards, Todd L; Kuhn, John E.; Jain, Nitin B.
2017-01-01
Background Rotator cuff disease is a common disorder leading to shoulder pain and loss of function. Its etiology in atraumatic cases is uncertain and likely extends beyond repetitive micro-trauma or overuse. Our objective was to determine whether there is a genetic or familial predisposition to rotator cuff disease. Methods A literature search of PubMed and EMBASE databases identified 251 citations. After reviewing the titles, abstracts, and full articles, seven met our inclusion/exclusion criteria. Results Four studies assessed familial predisposition to rotator cuff disease. One of these demonstrated that siblings of an individual with a rotator cuff tear were more likely to develop a full-thickness tear and more likely to be symptomatic. A five-year follow-up showed that the relative risks were increased for the siblings to have a full-thickness tear, for a tear to progress in size, and for being symptomatic. Another study demonstrated that a significantly higher number of individuals with tears had family members with a history of tears or surgery than those without tears. The other three studies investigated whether a genetic predisposition to rotator cuff disease exists and found significant association of haplotypes in DEFB1, FGFR1, FGFR3, ESRRB, and FGF10, and two single nucleotide polymorphisms within SAP30BP and SASH1. Conclusion Prior studies provide preliminary evidence for genetic and familial predisposition to rotator cuff disease. However, there is a lack of large genome-wide studies that can provide more definitive information and guide early detection of individuals at risk, prophylactic rehabilitation, and potential gene therapies and regenerative medicine interventions. Level of Evidence Systematic Review PMID:28162885
Vasanth Karthik, R; Ranganathan, Priya; Kulkarni, Atul P; Sharma, Kailash S
2014-10-01
The incidence of postoperative pharyngolaryngeal complications after laryngeal mask airway (LMA) insertion can be as high as 50%. Over-inflation of the LMA cuff may be a causal factor. We conducted a single-centre parallel group randomised trial to determine whether maintaining LMA-ProSeal intra-cuff pressures below 60 cm H2O decreases postoperative pharyngolaryngeal complications. We recruited 120 adult patients who were scheduled to undergo elective surgery under general anaesthesia. Appropriate sized LMA-ProSeal was inserted and the cuff was inflated with air (to no more than the maximum recommended volume) until there was no audible leak. Patients were randomised to either the control group (n = 60), where the intra-cuff pressure was noted and no further action was taken, or to the pressure-monitored group (n = 60), where intra-cuff pressure was maintained below 60 cm H2O. Pharyngolaryngeal complications consisting of sore throat, dysphonia and dysphagia were assessed at 1, 2, and 24 h postoperatively. Patients, anaesthesiologists and assessors were blinded to group allocation. The primary outcome was a composite endpoint of any pharyngolaryngeal complication at any of the three time points. Secondary outcomes were the incidence of individual outcomes at each time point. The incidence of pharyngolaryngeal complications at any time point was 42% in the routine care group and 32% in the pressure-monitored group (95% CI for difference +28 to -7%, p = 0.26). There was no difference between groups for any of the secondary outcomes. Our study failed to demonstrate a statistically significant reduction in postoperative pharyngolaryngeal complications by limiting intra-cuff pressures in the LMA-Proseal.
Park, Gi-Young; Kwon, Dong Rak; Lee, Sang Chul
2015-11-01
Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit's activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. ©AlphaMed Press.