Sample records for multiresidue analytical method

  1. Evaluation of a multiclass, multiresidue liquid chromatography-tandem mass spectrometry method for analysis of 120 veterinary drugs in bovine kidney

    USDA-ARS?s Scientific Manuscript database

    Traditionally, regulatory monitoring of veterinary drug residues in food animal tissues involves the use of several single-class methods to cover a wide analytical scope. Multiclass, multiresidue methods of analysis tend to provide greater overall laboratory efficiency than the use of multiple meth...

  2. Multiresidue analysis of pesticides in straw roughage by liquid chromatography - tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    A multiresidue analytical method using a modification of the “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) sample preparation approach combined with liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesti...

  3. Establishing and performing targeted multi-residue analysis for lipid mediators and fatty acids in small clinical plasma samples.

    USDA-ARS?s Scientific Manuscript database

    LC-MS/MS and GC-MS based targeted metabolomics is typically conducted by analyzing and quantifying a cascade of metabolites with methods specifically developed for the metabolite class. Here we describe an approach for the development of multi-residue analytical profiles, calibration standards, and ...

  4. Problems and solutions of polyethylene glycol co-injection method in multiresidue pesticide analysis by gas chromatography-mass spectrometry: evaluation of instability phenomenon in type II pyrethroids and its suppression by novel analyte protectants.

    PubMed

    Akutsu, Kazuhiko; Kitagawa, Yoko; Yoshimitsu, Masato; Takatori, Satoshi; Fukui, Naoki; Osakada, Masakazu; Uchida, Kotaro; Azuma, Emiko; Kajimura, Keiji

    2018-05-01

    Polyethylene glycol 300 is commonly used as a base material for "analyte protection" in multiresidue pesticide analysis via gas chromatography-mass spectrometry. However, the disadvantage of the co-injection method using polyethylene glycol 300 is that it causes peak instability in α-cyano pyrethroids (type II pyrethroids) such as fluvalinate. In this study, we confirmed the instability phenomenon in type II pyrethroids and developed novel analyte protectants for acetone/n-hexane mixture solution to suppress the phenomenon. Our findings revealed that among the examined additive compounds, three lipophilic ascorbic acid derivatives, 3-O-ethyl-L-ascorbic acid, 6-O-palmitoyl-L-ascorbic acid, and 6-O-stearoyl-L-ascorbic acid, could effectively stabilize the type II pyrethroids in the presence of polyethylene glycol 300. A mixture of the three ascorbic acid derivatives and polyethylene glycol 300 proved to be an effective analyte protectant for multiresidue pesticide analysis. Further, we designed and evaluated a new combination of analyte protectant compounds without using polyethylene glycol or the troublesome hydrophilic compounds. Consequently, we obtained a set of 10 medium- and long-chain saturated fatty acids as an effective analyte protectant suitable for acetone/n-hexane solution that did not cause peak instability in type II pyrethroids. These analyte protectants will be useful in multiresidue pesticide analysis by gas chromatography-mass spectrometry in terms of ruggedness and reliable quantitativeness. Graphical abstract Comparison of effectiveness of the addition of lipophilic derivatives of ascorbic acid in controlling the instability phenomenon of fluvalinate with polyethylene glycol 300.

  5. 77 FR 39895 - New Analytic Methods and Sampling Procedures for the United States National Residue Program for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-06

    ... Analytic Methods and Sampling Procedures for the United States National Residue Program for Meat, Poultry... implementing several multi-residue methods for analyzing samples of meat, poultry, and egg products for animal.... These modern, high-efficiency methods will conserve resources and provide useful and reliable results...

  6. Multi-residue analysis of pesticides, plant hormones, veterinary drugs and mycotoxins using HILIC chromatography - MS/MS in various food matrices.

    PubMed

    Danezis, G P; Anagnostopoulos, C J; Liapis, K; Koupparis, M A

    2016-10-26

    One of the recent trends in Analytical Chemistry is the development of economic, quick and easy hyphenated methods to be used in a field that includes analytes of different classes and physicochemical properties. In this work a multi-residue method was developed for the simultaneous determination of 28 xenobiotics (polar and hydrophilic) using hydrophilic interaction liquid chromatography technique (HILIC) coupled with triple quadrupole mass spectrometry (LC-MS/MS) technology. The scope of the method includes plant growth regulators (chlormequat, daminozide, diquat, maleic hydrazide, mepiquat, paraquat), pesticides (cyromazine, the metabolite of the fungicide propineb PTU (propylenethiourea), amitrole), various multiclass antibiotics (tetracyclines, sulfonamides quinolones, kasugamycin and mycotoxins (aflatoxin B1, B2, fumonisin B1 and ochratoxin A). Isolation of the analytes from the matrix was achieved with a fast and effective technique. The validation of the multi-residue method was performed at the levels: 10 μg/kg and 100 μg/kg in the following representative substrates: fruits-vegetables (apples, apricots, lettuce and onions), cereals and pulses (flour and chickpeas), animal products (milk and meat) and cereal based baby foods. The method was validated taking into consideration EU guidelines and showed acceptable linearity (r ≥ 0.99), accuracy with recoveries between 70 and 120% and precision with RSD ≤ 20% for the majority of the analytes studied. For the analytes that presented accuracy and precision values outside the acceptable limits the method still is able to serve as a semi-quantitative method. The matrix effect, the limits of detection and quantification were also estimated and compared with the current EU MRLs (Maximum Residue Levels) and FAO/WHO MLs (Maximum Levels) or CXLs (Codex Maximum Residue Limits). The combined and expanded uncertainty of the method for each analyte per substrate, was also estimated. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Validated LC–MS-MS Method for Multiresidual Analysis of 13 Illicit Phenethylamines in Amniotic Fluid

    PubMed Central

    Burrai, Lucia; Nieddu, Maria; Carta, Antonio; Trignano, Claudia; Sanna, Raimonda; Boatto, Gianpiero

    2016-01-01

    A multi-residue analytical method was developed for the determination in amniotic fluid (AF) of 13 illicit phenethylamines, including 12 compounds never investigated in this matrix before. Samples were subject to solid-phase extraction using; hydrophilic–lipophilic balance cartridges which gave good recoveries and low matrix effects on analysis of the extracts. The quantification was performed by liquid chromatography electrospray tandem mass spectrometry. The water–acetonitrile mobile phase containing 0.1% formic acid, used with a C18 reversed phase column, provided adequate separation, resolution and signal-to-noise ratio for the analytes and the internal standard. The final optimized method was validated according to international guidelines. A monitoring campaign to assess fetal exposure to these 13 substances of abuse has been performed on AF test samples obtained from pregnant women. All mothers (n = 194) reported no use of drugs of abuse during pregnancy, and this was confirmed by the analytical data. PMID:26755540

  8. Multi-residue method for the analysis of 85 current-use and legacy pesticides in bed and suspended sediments

    USGS Publications Warehouse

    Smalling, K.L.; Kuivila, K.M.

    2008-01-01

    A multi-residue method was developed for the simultaneous determination of 85 current-use and legacy organochlorine pesticides in a single sediment sample. After microwave-assisted extraction, clean-up of samples was optimized using gel permeation chromatography and either stacked carbon and alumina solid-phase extraction cartridges or a deactivated Florisil column. Analytes were determined by gas chromatography with ion-trap mass spectrometry and electron capture detection. Method detection limits ranged from 0.6 to 8.9 ??g/kg dry weight. Bed and suspended sediments from a variety of locations were analyzed to validate the method and 29 pesticides, including at least 1 from every class, were detected.

  9. A sensitive multi-residue method for the determination of 35 micropollutants including pharmaceuticals, iodinated contrast media and pesticides in water.

    PubMed

    Valls-Cantenys, Carme; Scheurer, Marco; Iglesias, Mònica; Sacher, Frank; Brauch, Heinz-Jürgen; Salvadó, Victoria

    2016-09-01

    A sensitive, multi-residue method using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed to determine a representative group of 35 analytes, including corrosion inhibitors, pesticides and pharmaceuticals such as analgesic and anti-inflammatory drugs, five iodinated contrast media, β-blockers and some of their metabolites and transformation products in water samples. Few other methods are capable of determining such a broad range of contrast media together with other analytes. We studied the parameters affecting the extraction of the target analytes, including sorbent selection and extraction conditions, their chromatographic separation (mobile phase composition and column) and detection conditions using two ionisation sources: electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI). In order to correct matrix effects, a total of 20 surrogate/internal standards were used. ESI was found to have better sensitivity than APCI. Recoveries ranging from 79 to 134 % for tap water and 66 to 144 % for surface water were obtained. Intra-day precision, calculated as relative standard deviation, was below 34 % for tap water and below 21 % for surface water, groundwater and effluent wastewater. Method quantification limits (MQL) were in the low ng L(-1) range, except for the contrast agents iomeprol, amidotrizoic acid and iohexol (22, 25.5 and 17.9 ng L(-1), respectively). Finally, the method was applied to the analysis of 56 real water samples as part of the validation procedure. All of the compounds were detected in at least some of the water samples analysed. Graphical Abstract Multi-residue method for the determination of micropollutants including pharmaceuticals, iodinated contrast media and pesticides in waters by LC-MS/MS.

  10. Validated LC-MS-MS Method for Multiresidual Analysis of 13 Illicit Phenethylamines in Amniotic Fluid.

    PubMed

    Burrai, Lucia; Nieddu, Maria; Carta, Antonio; Trignano, Claudia; Sanna, Raimonda; Boatto, Gianpiero

    2016-04-01

    A multi-residue analytical method was developed for the determination in amniotic fluid (AF) of 13 illicit phenethylamines, including 12 compounds never investigated in this matrix before. Samples were subject to solid-phase extraction using; hydrophilic-lipophilic balance cartridges which gave good recoveries and low matrix effects on analysis of the extracts. The quantification was performed by liquid chromatography electrospray tandem mass spectrometry. The water-acetonitrile mobile phase containing 0.1% formic acid, used with a C18 reversed phase column, provided adequate separation, resolution and signal-to-noise ratio for the analytes and the internal standard. The final optimized method was validated according to international guidelines. A monitoring campaign to assess fetal exposure to these 13 substances of abuse has been performed on AF test samples obtained from pregnant women. All mothers (n = 194) reported no use of drugs of abuse during pregnancy, and this was confirmed by the analytical data. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Application of a hybrid ordered mesoporous silica as sorbent for solid-phase multi-residue extraction of veterinary drugs in meat by ultra-high-performance liquid chromatography coupled to ion-trap tandem mass spectrometry.

    PubMed

    Casado, Natalia; Morante-Zarcero, Sonia; Pérez-Quintanilla, Damián; Sierra, Isabel

    2016-08-12

    A quick, sensitive and selective analytical reversed-phase multi-residue method using ultra-high performance liquid chromatography coupled to an ion-trap mass spectrometry detector (UHPLC-IT-MS/MS) operating in both positive and negative ion mode was developed for the simultaneous determination of 23 veterinary drug residues (β-blockers, β-agonists and Non-Steroidal Anti-inflammatory Drugs (NSAIDs)) in meat samples. The sample treatment involved a liquid-solid extraction followed by a solid-phase extraction (SPE) procedure. SBA-15 type mesoporous silica was synthetized and modified with octadecylsilane, and the resulting hybrid material (denoted as SBA-15-C18) was applied and evaluated as SPE sorbent in the purification of samples. The materials were comprehensively characterized, and they showed a high surface area, high pore volume and a homogeneous distribution of the pores. Chromatographic conditions and extraction procedure were optimized, and the method was validated according to the Commission Decision 2002/657/EC. The method detection limits (MDLs) and the method quantification limits (MQLs) were determined for all the analytes in meat samples and found to range between 0.01-18.75μg/kg and 0.02-62.50μg/kg, respectively. Recoveries for 15 of the target analytes ranged from 71 to 98%. In addition, for comparative purpose SBA-15-C18 was evaluated towards commercial C18 amorphous silica. Results revealed that SBA-15-C18 was clearly more successful in the multi-residue extraction of the 23 mentioned analytes with higher recovery values. The method was successfully tested to analyze prepacked preparations of mince bovine meat. Traces of propranolol, ketoprofen and diclofenac were detected in some samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Multiresidue method for detection of pesticides in beef meat using liquid chromatography coupled to mass spectrometry detection (LC-MS) after QuEChERS extraction.

    PubMed

    Oliveira, Fabiano Aurélio da Silva; Pereira, Elba Nathália Corrêa; Gobbi, Jennifer Mattedi; Soto-Blanco, Benito; Melo, Marília Martins

    2018-01-01

    Beef meat is an important food that can be contaminated by pesticides. This study aimed to optimize a multiresidue method for identification and quantification of pesticides in beef meat by liquid chromatography coupled to mass spectrometry detection (LC-MS). The extraction and clean-up procedures were adapted from the QuECHERS method. From the 188 analytes tested, the method was validated as qualitative method for 19 compounds and as quantitative method for 152 compounds. The results were satisfactory, yielding coefficients of variation of less than 20% and recoveries ranging from 70% to 120% and expanded uncertainty of less than 50%. The quantification limit was typically 10 µg kg -1 (but 25 µg kg -1 for 12 of the compounds) and the detection limit was 5.0 µg kg -1 . Thirty-two real samples of commercialized beef meat were analyzed without any residual pesticide being found. Thus, the results showed that the multiresidue method for detecting 171 pesticides, using adapted QuECHERS for extraction and LC-MS for detection, is suitable for analyzing beef meat.

  13. Multiresidue determination of 114 multiclass pesticides in flue-cured tobacco by solid-phase extraction coupled with gas chromatography and tandem mass spectrometry.

    PubMed

    Cao, Jianmin; Sun, Na; Yu, Weisong; Pang, Xueli; Lin, Yingnan; Kong, Fanyu; Qiu, Jun

    2016-12-01

    A sensitive and robust multiresidue method for the simultaneous analysis of 114 pesticides in tobacco was developed based on solid-phase extraction coupled with gas chromatography and tandem mass spectrometry. In this strategy, tobacco samples were extracted with acetonitrile and cleaned up with a multilayer solid-phase extraction cartridge Cleanert TPT using acetonitrile/toluene (3:1) as the elution solvent. Two internal standards of different polarity were used to meet simultaneous pesticides quantification demands in the tobacco matrix. Satisfactory linearity in the range of 10-500 ng/mL was obtained for all 114 pesticides with linear regression coefficients higher than 0.994. The limit of detection and limit of quantification values were 0.02-5.27 and 0.06-17.6 ng/g, respectively. For most of the pesticides, acceptable recoveries in the range of 70-120% and repeatabilities (relative standard deviation) of <11% were achieved at spiking levels of 20, 100, and 400 ng/g. Compared with the reported multiresidue analytical method, the proposed method provided a cleaner test solution with smaller amounts of pigments, fatty acids as well as other undesirable interferences. The development and validation of the high sensitivity, high selectivity, easy automation, and high-throughput analytical method meant that it could be successfully used for the determination of pesticides in tobacco samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Simultaneous determination of multiresidual phenyl acetanilide pesticides in different food commodities by solid-phase cleanup and gas chromatography-mass spectrometry.

    PubMed

    Li, Yongjun; Wang, Meiling; Yan, Hongfei; Fu, Shanliang; Dai, Hua

    2013-03-01

    An efficient and sensitive multiresidue method has been developed for quantification and confirmation of 25 phenyl acetanilide pesticides in a wide variety of food commodities including maize, spinach, mushroom, apple, soybean, chestnut, tea, beef, cattle liver, chicken, fish, and milk. Analytes were extracted with acetone-n-hexane (1:2, v/v) followed by cleanup using SPE. Several types of adsorbents were evaluated. Neutral aluminum and graphitized carbon black cartridge showed good cleanup efficiency. The extract was determined by GC-MS in the selected ion monitoring mode using one target and two qualitative ions for each analyte. The limits of detection were 0.01 mg/kg for all analytes. The average recoveries ranged from 66.9 to 110.6% (mean 88.8%) and RSDs were in the range 2.0-19% (mean 10.5%) across three fortification levels. The proposed method was successfully applied to real samples in routine analysis and a satisfactory result was obtained. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. A multiresidue method by high performance liquid chromatography-based fractionation and gas chromatographic determination of trace levels of pesticides in air and water.

    PubMed

    Seiber, J N; Glotfelty, D E; Lucas, A D; McChesney, M M; Sagebiel, J C; Wehner, T A

    1990-01-01

    A multiresidue analytical method is described for pesticides, transformation products, and related toxicants based upon high performance liquid chromatographic (HPLC) fractionation of extracted residue on a Partisil silica gel normal phase column followed by selective-detector gas chromatographic (GC) determination of components in each fraction. The HPLC mobile phase gradient (hexane to methyl t-butyl ether) gave good chromatographic efficiency, resolution, reproducibility and recovery for 61 test compounds, and allowed for collection in four fractions spanning polarities from low polarity organochlorine compounds (fraction 1) to polar N-methylcarbamates and organophosphorus oxons (fraction 4). The multiresidue method was developed for use with air samples collected on XAD-4 and related trapping agents, and water samples extracted with methylene chloride. Detection limits estimated from spiking experiments were generally 0.3-1 ng/m3 for high-volume air samples, and 0.01-0.1 microgram/L for one-liter water samples. Applications were made to determination of pesticides in fogwater and air samples.

  16. A quantitative method for residues of macrolide antibiotics in porcine kidney by liquid chromatography/tandem mass spectrometry.

    PubMed

    Dickson, Leslie C; O'Byrne, Collin; Chan, Wayne

    2012-01-01

    An LC/MS/MS-based multiresidue quantitative method was developed for the macrolides erythromycin A, neospiramycin I, oleandomycin, spiramycin I, tilmicosin, and tylosin A in porcine kidney tissues. The Canadian Food Inspection Agency (CFIA) had as part of its analytical scope an LC/UV method for quantification of residues of two macrolide antibiotics, tilmicosin and tylosin A, in the kidney, liver, and muscle of cattle, swine, and poultry. The method could not reliably detect concentrations below 10 microg/kg. To increase the scope of the CFIA's analytical capabilities, a sensitive multiresidue quantitative method for macrolide residues in food animal tissues was required. Porcine kidney samples were extracted with acetonitrile and alkaline buffer and cleaned-up using silica-based C18 SPE cartridges. Sample extracts were analyzed using LC/MS/MS with positive electrospray ionization. Fitness for purpose was verified in a single-laboratory validation study using a second analyst. The working analytical range was 5 to 50 microg/kg. LOD and LOQ were 0.5 to 0.6 microg/kg and 1.5 to 3.0 microg/kg, respectively. Limits of identification were 0.5 to 2.0 microg/kg. Relative intermediate precisions were 8 to 17%. Average absolute recoveries were 68 to 76%.

  17. Pesticide residues determination in Polish organic crops in 2007-2010 applying gas chromatography-tandem quadrupole mass spectrometry.

    PubMed

    Walorczyk, Stanisław; Drożdżyński, Dariusz; Kowalska, Jolanta; Remlein-Starosta, Dorota; Ziółkowski, Andrzej; Przewoźniak, Monika; Gnusowski, Bogusław

    2013-08-15

    A sensitive, accurate and reliable multiresidue method based on the application of gas chromatography-tandem quadrupole mass spectrometry (GC-QqQ-MS/MS) has been established for screening, identification and quantification of a large number of pesticide residues in produce. The method was accredited in compliance with PN-EN ISO/IEC 17025:2005 standard and it was operated under flexible scope as PB-11 method. The flexible scope of accreditation allowed for minor modifications and extension of the analytical scope while using the same analytical technique. During the years 2007-2010, the method was used for the purpose of verification of organic crop production by multiresidue analysis for the presence of pesticides. A total of 528 samples of differing matrices such as fruits, vegetables, cereals, plant leaves and other green parts were analysed, of which 4.4% samples contained pesticide residues above the threshold value of 0.01 mg/kg. A total of 20 different pesticide residues were determined in the samples. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Ruggedness testing and validation of a practical analytical method for > 100 veterinary drug residues in bovine muscle by ultrahigh performance liquid chromatography – tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    In this study, optimization, extension, and validation of a streamlined, qualitative and quantitative multiclass, multiresidue method was conducted to monitor great than100 veterinary drug residues in meat using ultrahigh-performance liquid chromatography – tandem mass spectrometry (UHPLC-MS/MS). I...

  19. MULTIRESIDUE DETERMINATION OF ACIDIC PESTICIDES IN WATER BY HPLC/DAD WITH CONFIRMATION BY GC/MS USING CONVERSION TO THE METHYL ESTER WITH TRIMETHYLSILYDIAZOMETHANE

    EPA Science Inventory

    A multiresidue pesticide methodology has been studied and results for acidics are reported here with base/neutral to follow. This work studies a literature procedure as a possible general approach to many pesticides and potentially other analytes that are considered to be liquid...

  20. ANALYTICAL METHODOLOGY FOR THE DETERMINATION OF KEPONE (TRADEMARK) RESIDUES IN FISH, SHELLFISH, AND HI-VOL AIR FILTERS

    EPA Science Inventory

    The recent discovery of the pollution of the environment with Kepone has resulted in a tremendous interest in the development of residue methodology for the compound. Current multiresidue methods for the determination of the common organochlorinated pesticides do not yield good q...

  1. Development of an UPLC-MS/MS Sulfonamide Multi-residue Method and It's Application to Water, Manure Slurry, and Soils from Swine Rearing Facilities

    USDA-ARS?s Scientific Manuscript database

    An analytical method was developed using ultra performance liquid chromatography-triple quadrupole-tandem mass spectrophotometry (UPLC-TQ-MS/MS) to simultaneously analyze 14 sulfonamides (SA) in six minutes. The instrumental detection limit based on signal-to-noise ratio (S/N) > 3, was below 1 pg/µL...

  2. Development of an UPLC-MS/MS Sulfonamide Multi-residue Method and its Application to Water, Manure Slurry, and Soils from Swine Rearing Facilities

    USDA-ARS?s Scientific Manuscript database

    An analytical method was developed using ultra performance liquid chromatography-triple quadrupole-tandem mass spectrometry (UPLC-TQ-MS/MS) to simultaneously analyze 14 sulfonamides (SA) in six minutes. Despite the rapidity of the assay the system was properly re-equilibrated in this time. No carryo...

  3. Pesticide Multiresidue Analysis in Cereal Grains Using Modified QuEChERS Method Combined with Automated Direct Sample Introduction GC-TOFMS and UPLC-MS/MS Techniques

    USDA-ARS?s Scientific Manuscript database

    The QuEChERS (quick, easy, cheap, effective, rugged, and safe) sample preparation method was modified to accommodate various cereal grain matrices (corn, oat, rice and wheat) and provide good analytical results (recoveries in the range of 70-120% and RSDs <20%) for the majority of the target pestici...

  4. A multiclass multiresidue LC-MS/MS method for analysis of veterinary drugs in bovine kidney

    USDA-ARS?s Scientific Manuscript database

    The increased efficiency permitted by multiclass, multiresidue methods has made such approaches very attractive to laboratories involved in monitoring veterinary drug residues in animal tissues. In this current work, evaluation of a multiclass multiresidue LC-MS/MS method in bovine kidney is describ...

  5. Residue analysis of sixty pesticides in red swamp crayfish using QuEChERS with high-performance liquid chromatography-tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    In this study, a multi-residue analytical method using QuEChERS extraction and dispersive solid-phase extraction (d-SPE) cleanup followed by high-performance liquid chromatography–tandem mass spectrometry (HPLC-MS/MS) was developed for rapid determination of 60 pesticide residues in whole crayfish a...

  6. Validation of a multi-residue method to determine deltamethrin and alpha-cypermethrin in mosquito nets by gas chromatography with electron capture detection (GC-μECD)

    PubMed Central

    2013-01-01

    Background Nowadays long-lasting insecticidal mosquito nets (LNs) are frequently used around the world to protect people against malaria vectors. As they contain insecticide, laboratory control is needed to check whether the content of the active ingredient follows the conditions of the manufacturer and also if the active ingredient is still present after some time of use. For this purpose, an analytical method had to be developed. The fact that LNs include a range of polymers for the yarn and use coated or incorporated technologies for the active ingredient, it is a challenge to find only one analytical method determining the active ingredient in LNs, which takes into account both impregnation technologies. Some methods are provided by international organizations but are limited by the determination of only one pesticide per method. The aim of this study was to optimize a short time extraction method for deltamethrin and alpha-cypermethrin from coated and incorporated mosquito nets and also to detect both insecticides in one analytical run, using gas chromatography with electron capture detection (GC-μECD). Methods Based on the literature, the most suitable solvent and the adequate extraction process for the insecticides used for net making were identified and adapted for the new multi-residue method. Results The validation data of the multi-residue method to determine deltamethrin and alpha-cypermethrin in mosquito nets by GC-μECD are given. Depending on the concentration of the active ingredient spiked on the nets, the mean recovery for alpha-cypermethrin ranged between 86% and 107% with a relative standard deviation below 3.5%. For deltamethrin it ranged between 90% and 108% with a relative standard deviation also below 3.5%. The limit of detection is 0.009 g.a.i/kg of net (0.3 mg a.i./m2 of net) both for alpha-cypermethrin and deltamethrin. Conclusions Data obtained are excellent. A 30 minutes reflux extraction method with xylene was developed to determine alpha-cypermethrin and deltamethrin in long-lasting insecticidal mosquito nets (LNs) by gas chromatography with electron capture detection (GC-μECD). The method can be easily extended to others pyrethroid used for mosquito net treatment. This paper also presents an overview of the studies dealing with pesticide determination in mosquito nets. PMID:23514225

  7. Optimization of detection conditions and single-laboratory validation of a multiresidue method for the determination of 135 pesticides and 25 organic pollutants in grapes and wine by gas chromatography time-of-flight mass spectrometry.

    PubMed

    Dasgupta, Soma; Banerjee, Kaushik; Dhumal, Kondiba N; Adsule, Pandurang G

    2011-01-01

    This paper describes single-laboratory validation of a multiresidue method for the determination of 135 pesticides, 12 dioxin-like polychlorinated biphenyls, 12 polyaromatic hydrocarbons, and bisphenol A in grapes and wine by GC/time-of-flight MS in a total run time of 48 min. The method is based on extraction with ethyl acetate in a sample-to-solvent ratio of 1:1, followed by selective dispersive SPE cleanup for grapes and wine. The GC/MS conditions were optimized for the chromatographic separation and to achieve highest S/N for all 160 target analytes, including the temperature-sensitive compounds, like captan and captafol, that are prone to degradation during analysis. An average recovery of 80-120% with RSD < 10% could be attained for all analytes except 17, for which the average recoveries were 70-80%. LOQ ranged within 10-50 ng/g, with < 25% expanded uncertainties, for 155 compounds in grapes and 151 in wine. In the incurred grape and wine samples, the residues of buprofezin, chlorpyriphos, metalaxyl, and myclobutanil were detected, with an RSD of < 5% (n = 6); the results were statistically similar to previously reported validated methods.

  8. Development, validation, and uncertainty measurement of multi-residue analysis of organochlorine and organophosphorus pesticides using pressurized liquid extraction and dispersive-SPE techniques.

    PubMed

    Sanyal, Doyeli; Rani, Anita; Alam, Samsul; Gujral, Seema; Gupta, Ruchi

    2011-11-01

    Simple and efficient multi-residue analytical methods were developed and validated for the determination of 13 organochlorine and 17 organophosphorous pesticides from soil, spinach and eggplant. Techniques namely accelerated solvent extraction and dispersive SPE were used for sample preparations. The recovery studies were carried out by spiking the samples at three concentration levels (1 limit of quantification (LOQ), 5 LOQ, and 10 LOQ). The methods were subjected to a thorough validation procedure. The mean recovery for soil, spinach and eggplant were in the range of 70-120% with median CV (%) below 10%. The total uncertainty was evaluated taking four main independent sources viz., weighing, purity of the standard, GC calibration curve and repeatability under consideration. The expanded uncertainty was well below 10% for most of the pesticides and the rest fell in the range of 10-20%.

  9. Analytical performance of the various acquisition modes in Orbitrap MS and MS/MS.

    PubMed

    Kaufmann, Anton

    2018-04-30

    Quadrupole Orbitrap instruments (Q Orbitrap) permit high-resolution mass spectrometry (HRMS)-based full scan acquisitions and have a number of acquisition modes where the quadrupole isolates a particular mass range prior to a possible fragmentation and HRMS-based acquisition. Selecting the proper acquisition mode(s) is essential if trace analytes are to be quantified in complex matrix extracts. Depending on the particular requirements, such as sensitivity, selectivity of detection, linear dynamic range, and speed of analysis, different acquisition modes may have to be chosen. This is particularly important in the field of multi-residue analysis (e.g., pesticides or veterinary drugs in food samples) where a large number of analytes within a complex matrix have to be detected and reliably quantified. Meeting the specific detection and quantification performance criteria for every targeted compound may be challenging. It is the aim of this paper to describe the strengths and the limitations of the currently available Q Orbitrap acquisition modes. In addition, the incorporation of targeted acquisitions between full scan experiments is discussed. This approach is intended to integrate compounds that require an additional degree of sensitivity or selectivity into multi-residue methods. This article is protected by copyright. All rights reserved.

  10. Inclusion of 1-naphthylacetic acid and 2-(1-naphthyl)acetamide into three typical multiresidue methods for LC/MS/MS analysis of tomatoes and zucchini.

    PubMed

    Lozano, Ana; Pérez-Parada, Andrés; Heinzen, Horacio; Fernández-Alba, Amadeo R

    2012-01-01

    In spite of high plant growth regulator application rates, little has been reported in the literature on determination of their residues in fruits and vegetables. This would be useful in monitoring good manufacturing practices and overall safety through the enforcement of maximum residue levels (MRLs). The present work describes method validation for the determination of 1-naphthylacetic acid (NAA) and 2(1-naphthyl)acetamide (NAAm) in tomato and zucchini using the mini-Luke, ethyl acetate (EtOAc) and acetate-buffered quick, easy, cheap, effective, rugged, and safe (QuEChERS) methods. Samples were spiked at two different levels: 50 and 100 pg/kg for NAA and 20 and 100 pg/kg for NAAm. These compounds were analyzed within the same chromatographic run with LC coupled to triple quadrupole MS (LC/(QqQ)MS/MS) in positive and negative electrospray ionization [ESI(+) and ESI(-)] modes for NAAm and NAA, respectively. For analyte confirmation, LC/ESI(-)QTOF-MS was also investigated given that NAA has only one multiple reaction monitoring transition (185.1-*140.9 m/z). These three common methods were used to determine linearity, recoveries, precision (RSD), matrix effects, repeatability, and reproducibility (n = 5) for the selected matrixes. In terms of the Directorate-General for Health and Consumers (DG-SANCO) guidelines, only insignificant differences were found for the multiresidue methods tested, regardless of the commodity. Matrix-matched calibration was used, and LODs were below 10.1 pg/kg for NAA and 6.0 pg/kg for NAAm, which were lower than the MRLs established in current European Union legislation for these compounds. Obtained recoveries for NAA ranged from 87 to 107% with RSD values below 10% for mini-Luke, 83 to 107% with RSD <11% for EtOAc, and 76 to 85% with RSD <7% for QuEChERS. NAAm recoveries ranged from 74 to 102% with RSD 5 15% for mini-Luke, 76 to 97% with RSD <4% for EtOAc, and 76 to 93% with RSD < 5% for QuEChERS. The linearity of the response over two orders of magnitude was demonstrated (r2 > 0.996) for all methods used. Good repeatability and reproducibility in terms of RSD were obtained (11.3-17.8%) for these analytical methods. The results were acceptable within the studied ranges for both analytes in all methods. As these multiresidue methods are used at the present time in many laboratories, this survey indicates that these analytes should be included in their monitoring scope.

  11. Community air monitoring for pesticides-part 2: multiresidue determination of pesticides in air by gas chromatography, gas chromatography-mass spectrometry, and liquid chromatography-mass spectrometry.

    PubMed

    Hengel, Matt; Lee, P

    2014-03-01

    Two multiresidue methods were developed to determine pesticides in air collected in California. Pesticides were trapped using XAD-4 resin and extracted with ethyl acetate. Based on an analytical method from the University of California Davis Trace Analytical Laboratory, pesticides were detected by analyzing the extract by gas chromatography-mass spectrometry (GC-MS) to determine chlorothalonil, chlorthal-dimethyl, cycloate, dicloran, dicofol, EPTC, ethalfluralin, iprodione, mefenoxam, metolachlor, PCNB, permethrin, pronamide, simazine, trifluralin, and vinclozolin. A GC with a flame photometric detector was used to determine chlorpyrifos, chlorpyrifos oxon, diazinon, diazinon oxon, dimethoate, dimethoate oxon, fonophos, fonophos oxon, malathion, malathion oxon, naled, and oxydemeton. Trapping efficiencies ranged from 78 to 92 % for low level (0.5 μg) and 37-104 % for high level (50 and 100 μg) recoveries. Little to no degradation of compounds occurred over 31 days; recoveries ranged from 78 to 113 %. In the California Department of Food and Agriculture (CDFA) method, pesticides were detected by analyzing the extract by GC-MS to determine chlorothalonil, chlorpyrifos, cypermethrin, dichlorvos, dicofol, endosulfan 1, endosulfan sulfate, oxyfluorfen, permethrin, propargite, and trifluralin. A liquid chromatograph coupled to a MS was used to determine azinphos-methyl, chloropyrifos oxon, DEF, diazinon, diazinon oxon, dimethoate, dimethoate oxon, diuron, EPTC, malathion, malathion oxon, metolachlor, molinate, norflurazon, oryzalin, phosmet, propanil, simazine and thiobencarb. Trapping efficiencies for compounds determined by the CDFA method ranged from 10 to 113, 22 to 114, and 56 to 132 % for 10, 5, and 2 μg spikes, respectively. Storage tests yielded 70-170 % recovery for up to 28 days. These multiresidue methods represent flexible, sensitive, accurate, and cost-effective ways to determine residues of various pesticides in ambient air.

  12. Multi-residue determination of 210 drugs in pork by ultra-high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Yin, Zhiqiang; Chai, Tingting; Mu, Pengqian; Xu, Nana; Song, Yue; Wang, Xinlu; Jia, Qi; Qiu, Jing

    2016-09-09

    This paper presents a multi-residue analytical method for 210 drugs in pork using ultra-high-performance liquid chromatography-Q-Trap tandem mass spectrometry (UPLC-MS/MS) within 20min via positive ESI in scheduled multi-reaction monitoring (MRM) mode. The 210 drugs, belonging to 21 different chemical classes, included macrolides, sulfonamides, tetracyclines, β-lactams, β-agonists, aminoglycosides, antiviral drugs, glycosides, phenothiazine, protein anabolic hormones, non-steroidal anti-inflammatory drugs (NSAIDs), quinolones, antifungal drugs, corticosteroids, imidazoles, piperidines, piperazidines, insecticides, amides, alkaloids and others. A rapid and simple preparation method was applied to process the animal tissues, including solvent extraction with an acetonitrile/water mixture (80/20, v/v), defatting and clean-up processes. The recoveries ranged from 52% to 130% with relative standard deviations (RSDs)<20% for spiked concentrations of 10, 50 and 250μg/kg. More than 90% of the analytes achieved low limits of quantification (LOQs)<10μg/kg. The decision limit (CCα), detection capability (CCβ) values were in the range of 2-502μg/kg and 4-505μg/kg, respectively. This method is significant for food safety monitoring and controlling veterinary drug use. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Development and validation of a multiresidue method for the analysis of polybrominated diphenyl ethers, new brominated and organophosphorus flame retardants in sediment, sludge and dust.

    PubMed

    Cristale, Joyce; Lacorte, Silvia

    2013-08-30

    This study presents a multiresidue method for simultaneous extraction, clean-up and analysis of priority and emerging flame retardants in sediment, sewage sludge and dust. Studied compounds included eight polybrominated diphenyl ethers congeners, nine new brominated flame retardants and ten organophosphorus flame retardants. The analytical method was based on ultrasound-assisted extraction with ethyl acetate/cyclohexane (5:2, v/v), clean-up with Florisil cartridges and analysis by gas chromatography coupled to tandem mass spectrometry (GC-EI-MS/MS). Method development and validation protocol included spiked samples, certified reference material (for dust), and participation in an interlaboratory calibration. The method proved to be efficient and robust for extraction and determination of three families of flame retardants families in the studied solid matrices. The method was applied to river sediment, sewage sludge and dust samples, and allowed detection of 24 among the 27 studied flame retardants. Organophosphate esters, BDE-209 and decabromodiphenyl ethane were the most ubiquitous contaminants detected. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Simultaneous liquid chromatography/mass spectrometry determination of both polar and "multiresidue" pesticides in food using parallel hydrophilic interaction/reversed-phase liquid chromatography and a hybrid sample preparation approach.

    PubMed

    Robles-Molina, José; Gilbert-López, Bienvenida; García-Reyes, Juan F; Molina-Díaz, Antonio

    2017-09-29

    Pesticide testing of foodstuffs is usually accomplished with generic wide-scope multi-residue methods based on liquid chromatography tandem mass spectrometry (LC-MS/MS). However, this approach does not cover some special pesticides, the so called "single-residue method" compounds, that are hardly compatible with standard reversed-phase (RP) separations due to their specific properties. In this article, we propose a comprehensive strategy for the integration of single residue method compounds and standard multiresidue pesticides within a single run. It is based on the use of a parallel LC column assembly with two different LC gradients performing orthogonal hydrophilic interaction chromatography (HILIC) and reversed-phase (RPLC) chromatography within one analytical run. Two sample aliquots were simultaneously injected on each column, using different gradients, being the eluents merged post-column prior to mass spectrometry detection. The approach was tested with 41 multiclass pesticides covering a wide range of physicochemical properties across several orders of log K ow (from -4 to +5.5). With this assembly, distinct separation from the void was attained for all the pesticides studied, keeping similar performance in terms of sensitivity, peak area reproducibility (<6 RSD% in most cases) and retention time stability of standard single column approaches (better than±0.1min). The application of the proposed approach using parallel HILIC/RPLC and RPLC/aqueous normal phase (Obelisc) were assessed in leek using LC-MS/MS. For this purpose, a hybrid QuEChERS (Quick, easy, cheap, effective, rugged and safe)/QuPPe (quick method for polar pesticides) method was evaluated based on solvent extraction with MeOH and acetonitrile followed by dispersive solid-phase extraction, delivering appropriate recoveries for most of the pesticides included in the study within the log K ow in the range from -4 to +5.5. The proposed strategy may be extended to other fields such as sport drug testing or environmental analysis, where the same type of variety of analytes featuring poor retention within a single chromatographic separation occurs. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Multi-class, multi-residue analysis of pesticides, polychlorinated biphenyls, polycyclic aromatic hydrocarbons, polybrominated diphenyl ethers and novel flame retardants in fish using fast, low-pressure gas chromatography-tandem mass spectrometry.

    PubMed

    Sapozhnikova, Yelena; Lehotay, Steven J

    2013-01-03

    A multi-class, multi-residue method for the analysis of 13 novel flame retardants, 18 representative pesticides, 14 polychlorinated biphenyl (PCB) congeners, 16 polycyclic aromatic hydrocarbons (PAHs), and 7 polybrominated diphenyl ether (PBDE) congeners in catfish muscle was developed and evaluated using fast low pressure gas chromatography triple quadrupole tandem mass spectrometry (LP-GC/MS-MS). The method was based on a QuEChERS (quick, easy, cheap, effective, rugged, safe) extraction with acetonitrile and dispersive solid-phase extraction (d-SPE) clean-up with zirconium-based sorbent prior to LP-GC/MS-MS analysis. The developed method was evaluated at 4 spiking levels and further validated by analysis of NIST Standard Reference Materials (SRMs) 1974B and 1947. Sample preparation for a batch of 10 homogenized samples took about 1h/analyst, and LP-GC/MS-MS analysis provided fast separation of multiple analytes within 9min achieving high throughput. With the use of isotopically labeled internal standards, recoveries of all but one analyte were between 70 and 120% with relative standard deviations less than 20% (n=5). The measured values for both SRMs agreed with certified/reference values (72-119% accuracy) for the majority of analytes. The detection limits were 0.1-0.5ng g(-1) for PCBs, 0.5-10ng g(-1) for PBDEs, 0.5-5ng g(-1) for select pesticides and PAHs and 1-10ng g(-1) for flame retardants. The developed method was successfully applied for analysis of catfish samples from the market. Published by Elsevier B.V.

  16. A multi-residue method for 17 anticoccidial drugs and ractopamine in animal tissues by liquid chromatography-tandem mass spectrometry and time-of-flight mass spectrometry.

    PubMed

    Matus, Johanna L; Boison, Joe O

    2016-05-01

    A new and sensitive multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) and liquid chromatography-quadrupole time-of-flight-mass spectrometry (LC-QToF-MS) method was developed and validated for the determination and confirmation of residues of 17 anticoccidials, plus free ractopamine in poultry muscle and liver, and bovine muscle, liver, and kidney tissues. The 17 anticoccidials are lasalocid, halofuginone, narasin, monensin, semduramicin, ethopabate, robenidine, buquinolate, toltrazuril as its sulfone metabolite, maduramicin, salinomycin, diclazuril, amprolium, decoquinate, dinitolmide, clopidol, and the nicarbazin metabolite DNC (N,N1-bis(4-nitrophenyl)urea). The analytes were extracted and cleaned up within a 3-hour period by simply extracting the analytes into a solvent mixture with salts followed by centrifugation, dilution, and filtration. The validated method was used in a pilot study for the analysis of 173 samples that included quail liver, bovine kidney, liver, muscle, and horse muscle. The predominant residues found in this study were monensin, ractopamine, and lasalocid. The results of this pilot study showed that this new method is applicable to real samples, and is fit for use in a regulatory testing programme. © 2016 Her Majesty the Queen in Right of Canada. Drug Testing and Analysis. © 2016 John Wiley & Sons, Ltd. © 2016 Her Majesty the Queen in Right of Canada. Drug Testing and Analysis. © 2016 John Wiley & Sons, Ltd.

  17. Development of a multi-residue method for the determination of human and veterinary pharmaceuticals and some of their metabolites in aqueous environmental matrices by SPE-UHPLC-MS/MS.

    PubMed

    Paíga, P; Santos, L H M L M; Delerue-Matos, C

    2017-02-20

    The aim of the present work was to develop and validate a multi-residue method for the analysis of 33 human and veterinary pharmaceuticals (non-steroidal anti-inflammatory drugs (NSAIDs)/analgesics, antibiotics and psychiatric drugs), including some of their metabolites, in several aqueous environmental matrices: drinking water, surface water and wastewaters. The method is based on solid phase extraction (SPE) followed by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) and it was validated for different aqueous matrices, namely bottled water, tap water, seawater, river water and wastewaters, showing recoveries between 50% and 112% for the majority of the target analytes. The developed analytical methodology allowed method detection limits in the low nanograms per liter level. Method intra- and inter-day precision was under 8% and 11%, respectively, expressed as relative standard deviation. The developed method was applied to the analysis of drinking water (bottled and tap water), surface waters (seawater and river water) and wastewaters (wastewater treatment plant (WWTP) influent and effluent). Due to the selectivity and sensitivity of the optimized method, it was possible to detect pharmaceuticals in all the aqueous environmental matrices considered, including in bottled water at concentrations up to 31ngL -1 (salicylic acid). In general, non-steroidal anti-inflammatory drugs/analgesics was the therapeutic group most frequently detected, with the highest concentrations found in wastewaters (acetaminophen and the metabolite carboxyibuprofen at levels up to 615 and 120μgL -1 , respectively). Copyright © 2016 Elsevier B.V. All rights reserved.

  18. A multiresidue method for determination of trace levels of pesticides in air and water.

    PubMed

    Millet, M; Wortham, H; Sanusi, A; Mirabel, P

    1996-11-01

    A multiresidue analytical method is described for the analysis of 13 pesticides in fogwater, rainwater, gas, and particles. This method is based upon solid-liquid extraction using Sep-Pak tC18 light cartridges for aqueous samples, soxhlet for gas (adsorbed on XAD-2) and particles (on glass fiber filters), HPLC-based fractionation of the extracted residues using a silica column, and a linear gradient of n-hexane/tert butyl methyl ether followed by GC-ECD and HPLC-UV analyses of each fraction. Prior to analysis with GC-ECD, a methylation procedure using BF3/methanol was developed for the analysis of the fraction which contains chlorophenoxy acid herbicides. The recoveries of the extraction procedure of liquid samples and of the methylation were greater than 92 and 97% with a standard deviation lower than 8 and 5%, respectively. The detection limits varied between 0.1 and 0.01 microgram.ml-1 for the 13 pesticides studied with a standard deviation less than 9%. This method was used for the determination of pesticides in 18 fogwater samples (soluble + insoluble), 31 rainwater samples, and 17 air (gas + particles) samples collected between 1991 and 1993 in Colmar (east of France).

  19. Multi-residue analysis of emerging pollutants in benthic invertebrates by modified micro-quick-easy-cheap-efficient-rugged-safe extraction and nanoliquid chromatography-nanospray-tandem mass spectrometry analysis.

    PubMed

    Berlioz-Barbier, Alexandra; Buleté, Audrey; Faburé, Juliette; Garric, Jeanne; Cren-Olivé, Cécile; Vulliet, Emmanuelle

    2014-11-07

    Aquatic ecosystems are continuously contaminated by agricultural and industrial sources. Although the consequences of this pollution are gradually becoming visible, their potential impacts on aquatic ecosystems are poorly known, particularly regarding the risk of bioaccumulation in different trophic levels. To establish a causality relationship between bioaccumulation and disease, experiments on biotic matrices must be performed. In this context, a multi-residue method for the analysis of 35 emerging pollutants in three benthic invertebrates (Potamopyrgus antipodarum, Gammarus fossarum, and Chironomus riparius) has been developed. Because the variation in response of each individual must be taken into account in ecotoxicological studies, the entire analytical chain was miniaturised, thereby reducing the required sample size to a minimum of one individual and scaling the method accordingly. A new extraction strategy based on a modified, optimised and miniaturised "QuEChERS" approach is reported. The procedure involves salting out liquid-liquid extraction of approximately 10-20mg of matrix followed by nano-liquid chromatography-nano electospray ionisation coupled with tandem mass spectrometry. The validated analytical procedure exhibited recoveries between 40 and 98% for all the target compounds and enabled the determination of pollutants on an individual scale in the ng g(-1) concentration. The method was subsequently applied to determine the levels of target analytes in several encaged organisms which were exposed upstream and downstream of an effluent discharge. The results highlighted a bioaccumulation of certain targeted emerging pollutants in three freshwater invertebrates, as well as inter-species differences. 18 out of 35 compounds were detected and eight were quantified. The highest concentrations were measured for ibuprofen in G. fossarum, reaching up to 105 ng g(-1). Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Multiresidue analysis of synthetic pyrethroid pesticides in grapes by gas chromatography with programmed temperature vaporizing-large volume injection coupled with ion trap mass spectrometry.

    PubMed

    Banerjee, Kaushik; Savant, Rahul H; Dasgupta, Soma; Patil, Sangram H; Oulkar, Dasharath P; Adsule, Pandurang G

    2010-01-01

    A multiresidue analysis method was optimized and validated for simultaneous estimation of 21 synthetic pyrethroid pesticides and their isomers in grape matrix at 10 ng/g and higher levels. The method involves extraction of a 10 g sample with 10 mL ethyl acetate, cleanup by dispersive SPE with primary-secondary amine (25 mg) sorbent, and estimation by GC/MS/MS large volume injection (LVI) through a programmed temperature vaporizer (PTV) injector. The PTV-LVI parameters of the gas chromatograph and the multiple reaction monitoring (MRM) parameters of the ion trap mass spectrometer were optimized for each compound to achieve the highest SIN. For each analyte, the unique and most abundant MRM transition was used for quantification, along with the next most abundant MRM transition for confirmatory identification. The abundance ratio of the confirmatory to quantifier MRMs was used to ensure unambiguous residue monitoring in unknown samples within a 20% tolerance range at the 10 ng/g level. The analytes were separated on a TR-5MS capillary column within a 22 min run time. The method was selective and sensitive and ensured separation of the synthetic pyrethroids from high-boiling matrix components. The LOD and LOQ of the analytes ranged between 0.5 to 3.1 and 2.5 to 10 ng/g, respectively. Linearity of solvent and matrix-matched calibrations between 2.0 and 250 ng/g was established for each compound with r2 > 0.99. Recovery at 10, 25, and 50 ng/g levels of fortification in grapes ranged within 77-115% with associated RSD values (n = 8) up to 20%.

  1. Multiresidue analysis of multiclass pesticides and polyaromatic hydrocarbons in fatty fish by gas chromatography tandem mass spectrometry and evaluation of matrix effect.

    PubMed

    Chatterjee, Niladri S; Utture, Sagar; Banerjee, Kaushik; Ahammed Shabeer, T P; Kamble, Narayan; Mathew, Suseela; Ashok Kumar, K

    2016-04-01

    This paper reports a selective and sensitive method for multiresidue determination of 119 chemical residues including pesticides and polyaromatic hydrocarbons (PAH) in high fatty fish matrix. The novel sample preparation method involved extraction of the target analytes from homogenized fish meat (5 g) in acetonitrile (15 mL, 1% acetic acid) after three-phase partitioning with hexane (2 mL) and the remaining aqueous layer. An aliquot (1.5 mL) of the acetonitrile layer was aspirated and subjected to two-stage dispersive solid phase extraction (dSPE) cleanup and the residues were finally estimated by gas chromatography mass spectrometry with selected reaction monitoring (GC-MS/MS). The co-eluted matrix components were identified on the basis of their accurate mass by GC with quadrupole time of flight MS. Addition of hexane during extraction and optimized dSPE cleanup significantly minimized the matrix effects. Recoveries at 10, 25 and 50 μg/kg were within 60-120% with associated precision, RSD<11%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Analytical methods for multiresidue determination of sulfonamides and trimethoprim in meat and ground water samples by CE-MS and CE-MS/MS.

    PubMed

    Soto-Chinchilla, Jorge J; García-Campaña, Ana M; Gámiz-Gracia, Laura

    2007-11-01

    This paper presents two methods based on CZE-MS detection and CZE-MS/MS detection developed for the multiresidue determination of ten sulfonamides (sulfapyridine, sulfadoxin, sulfamethazine, sulfadimethoxine, sulfameter, sulfamerazine, sulfachlorpyridazine, sulfadiazine, sulfamethoxazole, and sulfamethizole) and a potentiator, trimethoprim (TMP), whose contents are regulated by the EU Council Regulation no. 2377/90 in animal edible tissues. Experimental designs were employed to optimize the electrospray conditions. MS/MS experiments using an IT as analyzer operating in multiple reaction monitoring (MRM) mode were carried out to achieve the minimum number of points according to the 2002/657/EC European Decision for unambiguous identification. The proposed procedures have been compared in terms of the performance characteristics and trueness. The limits of detection and quantification were in all cases lower than the maximum residue limits legislated for these compounds and the recoveries were satisfactory, being possible the application for their monitoring in foodstuff of animal origin and in environmental samples, allowing the determination of sulfonamides and TMP residues in meat and in superficial water in the low microg/L range.

  3. Evaluation of the matrix effect on gas chromatography--mass spectrometry with carrier gas containing ethylene glycol as an analyte protectant.

    PubMed

    Fujiyoshi, Tomoharu; Ikami, Takahito; Sato, Takashi; Kikukawa, Koji; Kobayashi, Masato; Ito, Hiroshi; Yamamoto, Atsushi

    2016-02-19

    The consequences of matrix effects in GC are a major issue of concern in pesticide residue analysis. The aim of this study was to evaluate the applicability of an analyte protectant generator in pesticide residue analysis using a GC-MS system. The technique is based on continuous introduction of ethylene glycol into the carrier gas. Ethylene glycol as an analyte protectant effectively compensated the matrix effects in agricultural product extracts. All peak intensities were increased by this technique without affecting the GC-MS performance. Calibration curves for ethylene glycol in the GC-MS system with various degrees of pollution were compared and similar response enhancements were observed. This result suggests a convenient multi-residue GC-MS method using an analyte protectant generator instead of the conventional compensation method for matrix-induced response enhancement adding the mixture of analyte protectants into both neat and sample solutions. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Determination of linuron and related compounds in soil by microwave-assisted solvent extraction and reversed-phase liquid chromatography with UV detection.

    PubMed

    Molins, C; Hogendoorn, E A; Dijkman, E; Heusinkveld, H A; Baumann, R A

    2000-02-11

    The combination of microwave-assisted solvent extraction (MASE) and reversed-phase liquid chromatography (RPLC) with UV detection has been investigated for the efficient determination of phenylurea herbicides in soils involving the single-residue method (SRM) approach (linuron) and the multi-residue method (MRM) approach (monuron, monolinuron, isoproturon, metobromuron, diuron and linuron). Critical parameters of MASE, viz, extraction temperature, water content and extraction solvent were varied in order to optimise recoveries of the analytes while simultaneously minimising co-extraction of soil interferences. The optimised extraction procedure was applied to different types of soil with an organic carbon content of 0.4-16.7%. Besides freshly spiked soil samples, method validation included the analysis of samples with aged residues. A comparative study between the applicability of RPLC-UV without and with the use of column switching for the processing of uncleaned extracts, was carried out. For some of the tested analyte/matrix combinations the one-column approach (LC mode) is feasible. In comparison to LC, coupled-column LC (LC-LC mode) provides high selectivity in single-residue analysis (linuron) and, although less pronounced in multi-residue analysis (all six phenylurea herbicides), the clean-up performance of LC-LC improves both time of analysis and sample throughput. In the MRM approach the developed procedure involving MASE and LC-LC-UV provided acceptable recoveries (range, 80-120%) and RSDs (<12%) at levels of 10 microg/kg (n=9) and 50 microg/kg (n=7), respectively, for most analyte/matrix combinations. Recoveries from aged residue samples spiked at a level of 100 microg/kg (n=7) ranged, depending of the analyte/soil type combination, from 41-113% with RSDs ranging from 1-35%. In the SRM approach the developed LC-LC procedure was applied for the determination of linuron in 28 sandy soil samples collected in a field study. Linuron could be determined in soil with a limit of quantitation of 10 microg/kg.

  5. Multi-class multi-residue analysis of veterinary drugs in meat using enhanced matrix removal lipid cleanup and liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhao, Limian; Lucas, Derick; Long, David; Richter, Bruce; Stevens, Joan

    2018-05-11

    This study presents the development and validation of a quantitation method for the analysis of multi-class, multi-residue veterinary drugs using lipid removal cleanup cartridges, enhanced matrix removal lipid (EMR-Lipid), for different meat matrices by liquid chromatography tandem mass spectrometry detection. Meat samples were extracted using a two-step solid-liquid extraction followed by pass-through sample cleanup. The method was optimized based on the buffer and solvent composition, solvent additive additions, and EMR-Lipid cartridge cleanup. The developed method was then validated in five meat matrices, porcine muscle, bovine muscle, bovine liver, bovine kidney and chicken liver to evaluate the method performance characteristics, such as absolute recoveries and precision at three spiking levels, calibration curve linearity, limit of quantitation (LOQ) and matrix effect. The results showed that >90% of veterinary drug analytes achieved satisfactory recovery results of 60-120%. Over 97% analytes achieved excellent reproducibility results (relative standard deviation (RSD) < 20%), and the LOQs were 1-5 μg/kg in the evaluated meat matrices. The matrix co-extractive removal efficiency by weight provided by EMR-lipid cartridge cleanup was 42-58% in samples. The post column infusion study showed that the matrix ion suppression was reduced for samples with the EMR-Lipid cartridge cleanup. The reduced matrix ion suppression effect was also confirmed with <15% frequency of compounds with significant quantitative ion suppression (>30%) for all tested veterinary drugs in all of meat matrices. The results showed that the two-step solid-liquid extraction provides efficient extraction for the entire spectrum of veterinary drugs, including the difficult classes such as tetracyclines, beta-lactams etc. EMR-Lipid cartridges after extraction provided efficient sample cleanup with easy streamlined protocol and minimal impacts on analytes recovery, improving method reliability and consistency. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Quick and simple sample treatment for multiresidue analysis of bisphenols, bisphenol diglycidyl ethers and their derivatives in canned food prior to liquid chromatography and fluorescence detection.

    PubMed

    Alabi, A; Caballero-Casero, N; Rubio, S

    2014-04-04

    We report herein a multiresidue method for canned food determination of 12 bisphenols [bisphenol A (BPA), bisphenol B (BPB), bisphenol F (BPF), bisphenol E (BPE)], bisphenol diglycidyl ethers [bisphenol F diglycidyl ether (BFDGE), bisphenol A diglycidyl ether (BADGE)] and their derivatives [BADGE·2H2O, BADGE·H2O, BADGE·HCl·H2O, BADGE·HCl, BADGE·2HCl and BFDGE·2HCl]. The method was based on the microextraction of the target contaminants in 200mg food sample with 600 μL of a supramolecular solvent made up of inverse aggregates of tetradecanol, followed by analysis of the extract by liquid chromatography/fluorescence detection using external calibration. Chromatographic separation of all target compounds, including the ortho-ortho, ortho-para and para-para isomers of BFDGE and BFDGE·2HCl, was achieved with baseline separation (Resolution ≥ 1.52). No concentration of the extracts was required, the microextraction took about 30 min and several samples could be simultaneous treated. Method validation was carried out according to the recommendations of the European Commission Decision 2002/657/EC. Quantitation limits for the different analytes ranged between 0.9 and 3.5 μg kg(-1). Repeatability and reproducibility, expressed as relative standard deviation, were in the ranges 1.8-6.8% and 4.4-8.1%. The method was applied to the analysis of the target compounds in different food categories including vegetables, legumes, fruits, fish and seafood, meat product and grain. Recoveries in samples were within the range 80-110%. Only BPF and BPE were undetected in the canned food analyzed. The concentration found for the rest of bisphenols, diglycidyl ethers and derivatives was in the range 7.1-959 μg kg(-1). The study of the isomeric distribution of BFDGE and BFDGE·2HCl in food showed that they are preferentially present as one of the isomeric forms, that highlighting for further studies. The analytical and operational characteristics of this multiresidue method make it suitable for monitoring programs intended for the assessment of human exposure to bisphenols, diglycidyl ethers and derivatives from diet. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Validation of a GC-MS/MS method for simultaneous determination of 86 persistent organic pollutants in marine sediments by pressurized liquid extraction followed by stir bar sorptive extraction.

    PubMed

    Camino-Sánchez, F J; Zafra-Gómez, Alberto; Pérez-Trujillo, J P; Conde-González, J E; Marques, J C; Vílchez, José Luis

    2011-08-01

    A multiresidue method for the analysis of 86 persistent pollutants in marine sediments at ultra-trace level has been developed and validated using pressurized liquid extraction (PLE) and stir-bar sorptive extraction (SBSE) coupled with thermal desorption and gas chromatography-triple quadrupole mass spectrometry (TD-GC-MS/MS QqQ). The compounds analyzed belong to various families such as polychlorinated biphenyls, polycyclic aromatic hydrocarbons, polybrominated diphenylethers, organophosphorus and organochlorine pesticides and other pesticides such as urons, and triazines. The analytes have very different polarities and log K(ow) values, which is an important parameter in the optimization of a SBSE method. Due to PLE high efficiency and throughput rates, along with the proven ability for multiresidue analysis and excellent sensitivity of SBSE, we present an efficient method. The limits of quantification obtained ranged from 0.014 to 1.0 ng g(-1), with detection limits below pg g(-1) levels. In order to validate the proposed methodology, quality parameters such as recovery, linearity and reproducibility were studied. Recoveries ranged from 63% to 119%, reproducibility (in terms of Relative Standard Deviation for ten determinations) was lower than 35% in all cases, and determination coefficients higher than 0.990 for all analytes. The main factors that affect PLE, SBSE and GC-MS/MS procedures were optimized. The method was applied to the analysis of nine marine sediments obtained from the nine main submarine wastewater discharge points (emissaries) presents along the coast of Tenerife Island (Canary Islands, Spain). Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Development of a gas chromatography-mass spectrometry method for the determination of pesticides in gaseous and particulate phases in the atmosphere.

    PubMed

    Borrás, E; Sánchez, P; Muñoz, A; Tortajada-Genaro, L A

    2011-08-05

    A reliable multi-residue method for determining gaseous and particulate phase pesticides in atmospheric samples has been developed. This method, based on full scan gas chromatography-mass spectrometry (GC-MS), allowed the proper determination of sixteen relevant pesticides, in a wide range of concentrations and without the influence of interferences. The pesticides were benfluralin, bitertanol, buprofezin, chlorfenvinphos, chlorpyrifos, chlorpyrifos-methyl, ethalfluralin, fenthion, lindane, malathion, methidathion, propachlor, propanil, pyriproxifen, tebuconazol and trifluralin. Comparisons of two types of sampling filters (quartz and glass fibre) and four types of solid-phase cartridges (XAD-2, XAD-4, Florisil and Orbo-49P) showed that the most suitable supports were glass fibre filter for particulate pesticides and XAD-2 and XAD-4 cartridges for gaseous pesticides (>95% recovery). Evaluations of elution solvents for ultrasonic-assisted extraction demonstrated that isooctane is better than ethylacetate, dichloromethane, methanol or a mixture of acetone:hexane (1:1). Recovery assays and the standard addition method were performed to validate the proposed methodology. Moreover, large simulator chamber experiments allowed the best study of the gas-particle partitioning of pesticides for testing the sampling efficiency for the validation of an analytical multiresidue method for pesticides in air. Satisfactory analytical parameters were obtained, with a repeatability of 5±1%, a reproducibility of 13±3% and detection limits of 0.05-0.18 pg m(-3) for the particulate phase and 26-88 pg m(-3) for the gaseous phase. Finally, the methodology was successfully applied to rural and agricultural samples in the Mediterranean area. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. A simultaneous screening and quantitative method for the multiresidue analysis of pesticides in spices using ultra-high performance liquid chromatography-high resolution (Orbitrap) mass spectrometry.

    PubMed

    Goon, Arnab; Khan, Zareen; Oulkar, Dasharath; Shinde, Raviraj; Gaikwad, Suresh; Banerjee, Kaushik

    2018-01-12

    A novel screening and quantitation method is reported for non-target multiresidue analysis of pesticides using ultra-HPLC-quadrupole-Orbitrap mass spectrometry in spice matrices, including black pepper, cardamom, chili, coriander, cumin, and turmeric. The method involved sequential full-scan (resolution = 70,000), and variable data independent acquisition (vDIA) with nine consecutive fragmentation events (resolution = 17,500). Samples were extracted by the QuEChERS method. The introduction of an SPE-based clean-up step through hydrophilic-lipophilic-balance (HLB) cartridges proved advantageous in minimizing the false negatives. For coriander, cumin, chili, and cardamom, the screening detection limit was largely at 2 ng/g, while it was 5 ng/g for black pepper, and turmeric. When the method was quantitatively validated for 199 pesticides, the limit of quantification (LOQ) was mostly at 10 ng/g (excluding black pepper, and turmeric with LOQ = 20 ng/g) with recoveries within 70-120%, and precision-RSDs <20%. Furthermore, the method allowed the identification of suspected non-target analytes through retrospective search of the accurate mass of the compound-specific precursor and product ions. Compared to LC-MS/MS, the quantitative performance of this Orbitrap-MS method had agreements in residue values between 78-100%. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Analysis of 70 Environmental Protection Agency priority pharmaceuticals in water by EPA Method 1694.

    PubMed

    Ferrer, Imma; Zweigenbaum, Jerry A; Thurman, E Michael

    2010-09-03

    The U.S. Environmental Protection Agency (EPA) Method 1694 for the determination of pharmaceuticals in water recently brought a new challenge for treatment utilities, where pharmaceuticals have been reported in the drinking water of 41-million Americans. This proposed methodology, designed to address this important issue, consists of solid-phase extraction (SPE) followed by liquid chromatography-mass spectrometry (LC/MS-MS) using triple quadrupole. Under the guidelines of Method 1694, a multi-residue method was developed, validated, and applied to wastewater, surface water and drinking water samples for the analysis of 70 pharmaceuticals. Four distinct chromatographic gradients and LC conditions were used according to the polarity and extraction of the different pharmaceuticals. Positive and negative ion electrospray were used with two MRM transitions (a quantifier and a qualifier ion for each compound), which adds extra confirmation not included in the original Method 1694. Finally, we verify, for the first time, EPA Method 1694 on water samples collected in several locations in Colorado, where positive identifications for several pharmaceuticals were found. This study is a valuable indicator of the potential of LC/MS-MS for routine quantitative multi-residue analysis of pharmaceuticals in drinking water and wastewater samples and will make monitoring studies much easier to develop for water utilities across the US, who are currently seeking guidance on analytical methods for pharmaceuticals in their water supplies. 2010 Elsevier B.V. All rights reserved.

  11. Simultaneous multiresidue determination of metronidazole and spiramycin in fish muscle using high performance liquid chromatography with UV detection.

    PubMed

    Maher, Hadir M; Youssef, Rasha M; Khalil, Riad H; El-Bahr, Sabry M

    2008-12-15

    An efficient multiresidue method for the simultaneous determination of metronidazole (MET) and spiramycin (SPY) in tilapia fish muscle, based on high performance liquid chromatography with UV detection (HPLC-UV), has been developed. The drugs were extracted with 0.2% orthophosphoric acid-methanol (6:4), and the extracts were cleaned up on a solid phase extraction cartridge, C18 Sep-Pak light column. The LC separation was performed on a RP stainless-steel C-18 analytical column (150 mm x 4.6 mm, 5 microm) with a gradient elution system of 0.05 M phosphate buffer adjusted to pH 2.4-acetonitrile as the mobile phase at the flow rate of 1.0 ml min(-1). A wavelength programming was applied for the UV detection of the analytes. The method not only enabled the determination of the parent drugs, MET and SPY, but also permitted the determination of their metabolites, hydroxymetronidazole (HMET) and neospiramycin (NSPY). The calibration graphs for each drug were rectilinear in the range of 0.005-1.000 microg g(-1) for MET and HMET and 0.025-1.000 microg g(-1) for SPY and NSPY. With this method, the cited drugs with their metabolites were determined in fortified fish muscle tissues at levels of 0.025, 0.1 and 1.0 microg g(-1) with good accuracy and precision. LOD and LOQ obtained for each drug were as follows: 0.002 and 0.005 microg g(-1) for MET and HMET and 0.005 and 0.025 microg g(-1) for SPY and NSPY. Utilization of the method to successfully analyze tilapia fish muscle samples incurred with MET and SPY was described.

  12. Multiresidue determination of pesticides in tea by gas chromatography-tandem mass spectrometry.

    PubMed

    Saito-Shida, Shizuka; Nemoto, Satoru; Teshima, Reiko

    2015-01-01

    An efficient and reliable GC-MS/MS method for the multiresidue determination of pesticides in tea was developed by modifying the Japanese official multiresidue method. Sample preparation was carefully optimized for the efficient removal of coextracted matrix components. The optimal sample preparation procedure involved swelling of the sample in water; extraction with acetonitrile; removal of water by salting-out; and sequential cleanup by ODS, graphitized carbon black/primary secondary amine (GCB/PSA) and silica gel cartridges prior to GC-MS/MS analysis. The recoveries of 162 pesticides from fortified (at 0.01 mg kg(-1)) green tea, oolong tea, black tea and matcha (powdered green tea) were mostly (95-98% of the tested pesticides) within the range of 70-120%, with relative standard deviations of <20%. Poor recovery of triazole pesticides was considered to be due to low recovery from the silica gel cartridges. The test solutions obtained by the modified method contained relatively small amounts of pigments, caffeine and other matrix components and were cleaner than those obtained by the original Japanese official multiresidue method. No interfering peaks were observed in the blank chromatograms, indicating the high selectivity of the modified method. The overall results suggest that the developed method is suitable for the quantitative analysis of GC-amenable pesticide residues in tea.

  13. Development and validation of a multi-residue method for the analysis of brominated and organophosphate flame retardants in indoor dust.

    PubMed

    He, Chang; Wang, Xianyu; Thai, Phong; Mueller, Jochen F; Gallen, Christie; Li, Yan; Baduel, Christine

    2017-03-01

    Flame retardants are associated to numerous adverse health effects, can accumulate in humans and have been used intensively worldwide. Recently, dust has been identified as a major human exposure route for flame retardants. The aim of this study was to develop a multi-residue method using a two-step SPE purification. It enabled us to effectively limit co-extracted matrix/interferets and therefore a simultaneous analysis of brominated and organophosphate flame retardants for indoor dust was achieved. The optimized method was validated according to standard protocol and achieved good accuracy and reproducibility (percent error ranged from -29% to 28%). Standard Reference Material (SRM) for dust was also analysed, and good agreement was found with reported brominated and organophosphate flame retardants (OPFRs) concentrations. The applicability of the validated method was demonstrated by the analysis of ten indoor dust samples from ten Australian homes. Overall 89% of the analytes were detected in these samples. The average concentrations of ∑OPFRs and ∑PBDEs in those samples were 41 and 3.6μg/g, respectively. Tris(2-butoxyethyl) phosphate and tris(2-chloroisopropyl) phosphate were the most abundant OPFRs, accounting for 57-92% ∑OPFRs, while decabromodiphenyl ether dominated the Polybrominated diphenyl ethers (PBDE) congeners contributing between 71-94% to the ∑PBDEs. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. High-Throughput Analytical Techniques for Determination of Residues of 653 Multiclass Pesticides and Chemical Pollutants in Tea--Part V: A Comparative Study of the Influence of Tea Hydration on the Efficiency of Pesticide Multiresidue Determination Using Three Sample Preparation Methods and GC/MS/MS.

    PubMed

    Chen, Xi; Li, Yan; Chang, Qiao-Ying; Hu, Xue-Yan; Pang, Guo-Fang; Fan, Chun-Lin

    2015-01-01

    This paper describes a comparative study of the influence of three sample preparation techniques (M1: hydration+oscillating extraction+partial extraction solution hexane partitioning cleanup; M2: hydration+oscillating extraction+overall extraction solution SPE cleanup; and M3: pure acetonitrile homogeneous extraction+overall extraction SPE cleanup) on the determination efficiency of 456 pesticide multiresidues in tea. First, it was discovered from the mathematical correlation equation of 329 pesticide recoveries established and log Kow values that the extraction efficiency of hydration method M1 has obvious correlation with pesticide log Kow, making the extraction efficiency of M1 take the shape of an arc trend line with a certain arc hanging down from both ends of polar pesticides and nonpolar pesticides. Second, regarding the M1 method, the interfering matter after co-extraction increased in large quantities, which markedly lowered the S/N of the target pesticides and method sensitivity, leading to an obvious decrease of the method efficiency. The fortification experiment of the uniform limit 0.010 mg/kg proved that with the M1 hydration method there are 23 pesticides with recoveries between 70 and 120% and RSD<20%, accounting for only 5.0%, while with nonhydration method M3 there are 229 pesticides, making up 50%.

  15. Multi-class, multi-residue analysis of pesticides, polychlorinated biphenyls, polycyclic aromatic hydrocarbons, polybrominated diphenyl ethers and novel flame retardants....mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    A multi-class, multi-residue method for the analysis of 13 novel flame retardants, 18 representative pesticides, 14 polychlorinated biphenyl (PCB) congeners, 16 polycyclic aromatic hydrocarbons (PAHs), and 7 polybrominated diphenyl ether (PBDE) congeners in catfish muscle was developed and evaluated...

  16. Simultaneous LC-MS/MS determination of 40 legal and illegal psychoactive drugs in breast and bovine milk.

    PubMed

    López-García, Ester; Mastroianni, Nicola; Postigo, Cristina; Valcárcel, Yolanda; González-Alonso, Silvia; Barceló, Damia; López de Alda, Miren

    2018-04-15

    This work presents a fast, sensitive and reliable multi-residue methodology based on fat and protein precipitation and liquid chromatography-tandem mass spectrometry for the determination of common legal and illegal psychoactive drugs, and major metabolites, in breast milk. One-fourth of the 40 target analytes is investigated for the first time in this biological matrix. The method was validated in breast milk and also in various types of bovine milk, as tranquilizers are occasionally administered to food-producing animals. Absolute recoveries were satisfactory for 75% of the target analytes. The use of isotopically labeled compounds assisted in correcting analyte losses due to ionization suppression matrix effects (higher in whole milk than in the other investigated milk matrices) and ensured the reliability of the results. Average method limits of quantification ranged between 0.4 and 6.8 ng/mL. Application of the developed method showed the presence of caffeine in breast milk samples (12-179 ng/mL). Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Simultaneous determination of quinolones in fish by liquid chromatography coupled with fluorescence detection: comparison of sub-2 microm particles and conventional C18 columns.

    PubMed

    Zhang, Hong; Chen, Si; Lu, Yanbin; Dai, Zhiyuan

    2010-07-01

    A simple and effective multi-residue analysis method is presented for the extraction and determination of eleven quinolones (pipemidic acid, enoxacin, norfloxacin, ciprofloxacin, lomefloxacin, enrofloxacin, gatifloxacin, difloxacin, oxolinic acid, nalidixic acid and flumequine) in fish tissues. In this study, multi-residue separations on four columns packed with 5 microm or sub-2 microm particles were simultaneously developed for the purpose of comparison. Various gradients were optimized and best resolutions were achieved on each column. A short and sub-2 microm particle-sized HPLC column was chosen for its advantages in analysis time and column performance. Additionally, considering the matrix effect of the complex crude fish tissue, an effective extraction protocol was also established for sample pre-treatment procedure. Good recoveries (71-98%) were obtained from samples fortified with a mix of eleven quinolones at three levels, with satisfactory relative standard deviations and limits of detection. As a result, the sub-2 microm HPLC column and proposed analytical procedures have been evaluated and applied to the analysis of different fish tissues. Detectable residues were observed in 8 of 30 samples, at concentrations ranging from 4.74 to 23.27 microg/kg.

  18. Miniaturized QuEChERS based methodology for multiresidue determination of pesticides in odonate nymphs as ecosystem biomonitors.

    PubMed

    Jesús, Florencia; Hladki, Ricardo; Gérez, Natalia; Besil, Natalia; Niell, Silvina; Fernández, Grisel; Heinzen, Horacio; Cesio, María Verónica

    2018-02-01

    The impacts of the modern, agrochemicals based agriculture that threatens the overall systems sustainability, need to be monitored and evaluated. Seeking for agroecosystems monitors, the present article focus in the occurrence and abundance of aquatic macroinvertebrates, that have been frequently used as bioindicators of water quality due to their relationship with land use. Some of these organisms are on the top of the food chain, where bioaccumulation and biomagnification processes can be observed, and they can turn into secondary pollution sources of systems and terrestrial organisms as well. Odonate nymphs, which belong to the functional group of predators, were selected for this study. A methodology to determine 73 pesticide residues in odonate nymphs by LC-MS/MS and GC-MS/MS was developed. A QuEChERS sample preparation strategy was adapted. As it is complex to obtain samples especially in disturbed ecosystems, the method was minimized to a sample size of 200mg of fresh nymphs. The method was validated and good recoveries (71-120%) with RSDs below 20% for the majority of the studied pesticides at least at two of the assayed levels 1, 10 and 50µgkg -1 were obtained. For 32 analytes the limit of quantitation was 1µgkg -1 and 10µgkg -1 for the others. The lineal range was observed between 1-100µgkg -1 in matrix-matched and solvent calibration curves for most of the assessed pesticides. LC-MS/MS matrix effects were evaluated, 40% of the analytes presented low or no signal suppression. Only flufenoxuron presented high matrix effects. The obtained methodology is adequate for pesticide multiresidue analysis in aquatic macroinvertebrates (odonates) aiming to contribute to the ecological state evaluation of freshwater ecosystems. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. A rapid miniaturized residue analytical method for the determination of zoxamide and its two acid metabolites in ginseng roots using UPLC-MS/MS.

    PubMed

    Podhorniak, Lynda V

    2014-04-30

    A miniaturized residue method was developed for the analysis of the fungicide zoxamide and its metabolites in dried ginseng root. The zoxamide metabolites, 3,5-dichloro-1,4-benzenedicarboxylic acid (DCBC) and 3,5-dichloro-4-hydroxymethylbenzoic acid (DCHB), are small acid molecules that have not been previously extracted from the ginseng matrix with common multiresidue methods. The presented extraction method effectively and rapidly recovers both the zoxamide parent compound and its acid metabolites from fortified ginseng root. The metabolites are extracted with an alkaline glycine buffer and the aqueous ginseng mixture is partitioned with ethyl acetate. In addition, this method avoids the use of derivatization of the small acid molecules by using UPLC-MS/MS instrumental analysis. In a quantitative validation of the analytical method at three levels for zoxamide (0.007 (LOD), 0.02 (LOQ), and 0.2 mg/kg) and four levels (0.07 (LOD), 0.2 (LOQ), and 0.6 and 6 mg/kg) for both metabolites, acceptable method performances were achieved with recoveries ranging from 86 to 107% (at levels of LOQ and 3×, 10×, and 30× the LOQ) with <20% RSD for the three analytes in accordance with international guidelines.1.

  20. Multiresidue analysis of 22 sulfonamides and their metabolites in animal tissues using quick, easy, cheap, effective, rugged, and safe extraction and high resolution mass spectrometry (hybrid linear ion trap-Orbitrap).

    PubMed

    Abdallah, H; Arnaudguilhem, C; Jaber, F; Lobinski, R

    2014-08-15

    A new high performance liquid chromatography-high resolution mass spectrometry (HPLC-HRMS) method was developed for a simultaneous multi-residue analysis of 22 sulfonamides (SAs) and their metabolites in edible animal (pig, beef, sheep and chicken) tissues. Sample preparation was optimized on the basis of the "QuEChERS" protocol. The analytes were identified using their LC retention times and accurate mass; the identification was further confirmed by multi-stage high mass accuracy (<5ppm) mass spectrometry. The performance of the method was evaluated according to the EU guidelines for the validation of screening methods for the analysis of veterinary drugs residues. Acceptable values were obtained for: linearity (R(2)<0.99), limit of detection (LOD, 3-26μg/kg), limit of quantification (LOQ, 11-88μg/kg), accuracy (recovery 88-112%), intra- and inter-day precision 1-14 and 1-17%, respectively, decision limit (CCα) and detection capability (CCβ) around the maximum residue limits (MRL) of SAs (100μg/kg). The method was validated by analysis of a reference material FAPAS-02188 "Pig kidney" with ǀ Z-scoreǀ<0.63. The method was applied to various matrices (kidney, liver, muscle) originated from pig, beef, sheep, and chicken) allowing the simultaneous quantification of target sulfonamides at concentration levels above the MRL/2 and the identification of untargeted compounds such as N(4)-acetyl metabolites using multi-stage high mass accuracy mass spectrometry. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Multiresidue analytical method for pharmaceuticals and personal care products in sewage and sewage sludge by online direct immersion SPME on-fiber derivatization - GCMS.

    PubMed

    López-Serna, Rebeca; Marín-de-Jesús, David; Irusta-Mata, Rubén; García-Encina, Pedro Antonio; Lebrero, Raquel; Fdez-Polanco, María; Muñoz, Raúl

    2018-08-15

    The work here presented aimed at developing an analytical method for the simultaneous determination of 22 pharmaceuticals and personal care products, including 3 transformation products, in sewage and sludge. A meticulous method optimization, involving an experimental design, was carried out. The developed method was fully automated and consisted of the online extraction of 17 mL of water sample by Direct Immersion Solid Phase MicroExtraction followed by On-fiber Derivatization coupled to Gas Chromatography - Mass Spectrometry (DI-SPME - On-fiber Derivatization - GC - MS). This methodology was validated for 12 of the initial compounds as a reliable (relative recoveries above 90% for sewage and 70% for sludge; repeatability as %RSD below 10% in all cases), sensitive (LODs below 20 ng L -1 in sewage and 10 ng g -1 in sludge), versatile (sewage and sewage-sludge samples up to 15,000 ng L -1 and 900 ng g -1 , respectively) and green analytical alternative for many medium-tech routine laboratories around the world to keep up with both current and forecast environmental regulations requirements. The remaining 10 analytes initially considered showed insufficient suitability to be included in the final method. The methodology was successfully applied to real samples generated in a pilot scale sewage treatment reactor. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Automated multi-plug filtration cleanup for liquid chromatographic-tandem mass spectrometric pesticide multi-residue analysis in representative crop commodities.

    PubMed

    Qin, Yuhong; Zhang, Jingru; Zhang, Yuan; Li, Fangbing; Han, Yongtao; Zou, Nan; Xu, Haowei; Qian, Meiyuan; Pan, Canping

    2016-09-02

    An automated multi-plug filtration cleanup (m-PFC) method on modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) extracts was developed. The automatic device was aimed to reduce labor-consuming manual operation workload in the cleanup steps. It could control the volume and the speed of pulling and pushing cycles accurately. In this work, m-PFC was based on multi-walled carbon nanotubes (MWCNTs) mixed with other sorbents and anhydrous magnesium sulfate (MgSO4) in a packed tip for analysis of pesticide multi-residues in crop commodities followed by liquid chromatography with tandem mass spectrometric (LC-MS/MS) detection. It was validated by analyzing 25 pesticides in six representative matrices spiked at two concentration levels of 10 and 100μg/kg. Salts, sorbents, m-PFC procedure, automated pulling and pushing volume, automated pulling speed, and pushing speed for each matrix were optimized. After optimization, two general automated m-PFC methods were introduced to relatively simple (apple, citrus fruit, peanut) and relatively complex (spinach, leek, green tea) matrices. Spike recoveries were within 83 and 108% and 1-14% RSD for most analytes in the tested matrices. Matrix-matched calibrations were performed with the coefficients of determination >0.997 between concentration levels of 10 and 1000μg/kg. The developed method was successfully applied to the determination of pesticide residues in market samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Development and validation of a multiresidue method for the simultaneous determination of organophosphorus insecticides and their toxic metabolites in sugarcane juice and refined sugar by gas chromatography with flame photometric detection.

    PubMed

    Ramasubramanian, Thirumalaiandi; Paramasivam, Mariappan

    2016-06-01

    A multiresidue method has been developed and validated for the simultaneous determination of organophosphorus insecticides and their toxic metabolites in sugarcane juice and refined sugar by gas chromatography with flame photometric detection. Limits of quantification of the method varied between 0.007 and 0.01 μg/g. Ethyl acetate based extraction followed by dispersive solid-phase extraction cleanup with primary secondary amine yielded internationally acceptable recoveries of acephate, chlorpyrifos, dichlorvos, monocrotophos, malathion, malaoxon, phorate, phorate-sulfoxide, phorate-oxon, phorate-sulfone, and quinalphos from selected matrices. The recoveries of target analytes from cane juice were 75.55 ± 0.5-102.57 ± 4.2, 77.45 ± 4.7-103.33 ± 3.3, and 80.55 ± 6.6-105.82 ± 9.8% at 0.01, 0.02, and 0.1 μg/g levels of fortification, respectively. The recoveries from cane sugar were 73.24 ± 3.5-104.47 ± 1.9, 75.23 ± 1.5-116.10 ± 3.7, and 70.75 ± 5.7-110.15 ± 2.7%, respectively at 0.01, 0.02, and 0.1 μg/g levels of fortification. Matrix effect and measurement uncertainty were within the permissible limit (less than 20%) as prescribed for pesticide residue analysis. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Quantitative multiresidue analysis of antibiotics in milk and milk powder by ultra-performance liquid chromatography coupled to tandem quadrupole mass spectrometry.

    PubMed

    Tian, He; Wang, Jiaqi; Zhang, Yangdong; Li, Songli; Jiang, Jindou; Tao, Dali; Zheng, Nan

    2016-10-15

    A simple and fast multiresidue extraction and purification method was developed for the determination of 61 veterinary drugs, belonging to seven classes, in milk and milk powder. The extraction depends on the acetonitrile solvent, followed by a single step to remove lipids with fatty acid chains using a new reversed phase SPE without traditional pre-equilibration and washing steps before eluting SPE. The purifying lipid effect of the present preparation method was evaluated by comparing the response changes of ion peak areas of the milk endogenous metabolites before and after SPE treatment using ultra-fast LC coupled to tandem quadrupole and TOF MS. Subsequently, UPLC coupled to tandem quadrupole MS was performed for the quantitative analysis of milk and milk powder samples spiked with 61 veterinary drugs, including β-lactam, macrolide, amide alcohol, forest amine, sulfanilamide, tetracyclines, and quinolones antibiotics. This method is very simple, fast, sensitive, and selective, and allows the good recoveries of all compounds, with a recovery range of 61.5-118.6%, and coefficients of variation of less than 11.6%. The 61 compounds behave in the dynamic range 0.01-200μgkg(-1), with correlation coefficient >0.99. The limits of quantification for the analytes are in the range 0.01-5.18μgkg(-1). Finally, this method has been successfully applied to the screening of veterinary drugs in 50 commercial bovine milk and milk powder samples, and ceftiofur and ciprofloxacin were detected in some brand samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Plant protection product residues in white grapes and wines of "Malvasia Istriana" produced in Istria.

    PubMed

    Baša Česnik, Helena; Velikonja Bolta, Špela; Bavčar, Dejan; Radeka, Sanja; Lisjak, Klemen

    2016-12-01

    Monitorting of plant protection product residues was performed in 12 grape and 66 wine samples of "Malvasia Istriana" variety, produced in Istria winegrowing region of Croatia and Slovenia. The samples were analysed for the presence of 169 different active compounds using two multiresidual analytical methods: gas chromatography coupled with mass spectrometry and liquid chromatography coupled with tandem mass spectrometry. Residues were found in 58.3% of all the inspected grape samples and in 28.8% of all the inspected wine samples. Beside that contents of residues in grapes were below 10% of maximum residue level values and they should not represent any risk for "Malvasia Istriana" grape or wine consumers.

  6. Matrix interference evaluation employing GC and LC coupled to triple quadrupole tandem mass spectrometry.

    PubMed

    Uclés, S; Lozano, A; Sosa, A; Parrilla Vázquez, P; Valverde, A; Fernández-Alba, A R

    2017-11-01

    Gas and liquid chromatography coupled to triple quadrupole tandem mass spectrometry are currently the most powerful tools employed for the routine analysis of pesticide residues in food control laboratories. However, whatever the multiresidue extraction method, there will be a residual matrix effect making it difficult to identify/quantify some specific compounds in certain cases. Two main effects stand out: (i) co-elution with isobaric matrix interferents, which can be a major drawback for unequivocal identification, and therefore false negative detections, and (ii) signal suppression/enhancement, commonly called the "matrix effect", which may cause serious problems including inaccurate quantitation, low analyte detectability and increased method uncertainty. The aim of this analytical study is to provide a framework for evaluating the maximum expected errors associated with the matrix effects. The worst-case study contrived to give an estimation of the extreme errors caused by matrix effects when extraction/determination protocols are applied in routine multiresidue analysis. Twenty-five different blank matrices extracted with the four most common extraction methods used in routine analysis (citrate QuEChERS with/without PSA clean-up, ethyl acetate and the Dutch mini-Luke "NL" methods) were evaluated by both GC-QqQ-MS/MS and LC-QqQ-MS/MS. The results showed that the presence of matrix compounds with isobaric transitions to target pesticides was higher in GC than under LC in the experimental conditions tested. In a second study, the number of "potential" false negatives was evaluated. For that, ten matrices with higher percentages of natural interfering components were checked. Additionally, the results showed that for more than 90% of the cases, pesticide quantification was not affected by matrix-matched standard calibration when an interferent was kept constant along the calibration curve. The error in quantification depended on the concentration level. In a third study, the "matrix effect" was evaluated for each commodity/extraction method. Results showed 44% of cases with suppression/enhancement for LC and 93% of cases with enhancement for GC. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Analytical difficulties facing today's regulatory laboratories: issues in method validation.

    PubMed

    MacNeil, James D

    2012-08-01

    The challenges facing analytical laboratories today are not unlike those faced in the past, although both the degree of complexity and the rate of change have increased. Challenges such as development and maintenance of expertise, maintenance and up-dating of equipment, and the introduction of new test methods have always been familiar themes for analytical laboratories, but international guidelines for laboratories involved in the import and export testing of food require management of such changes in a context which includes quality assurance, accreditation, and method validation considerations. Decisions as to when a change in a method requires re-validation of the method or on the design of a validation scheme for a complex multi-residue method require a well-considered strategy, based on a current knowledge of international guidance documents and regulatory requirements, as well the laboratory's quality system requirements. Validation demonstrates that a method is 'fit for purpose', so the requirement for validation should be assessed in terms of the intended use of a method and, in the case of change or modification of a method, whether that change or modification may affect a previously validated performance characteristic. In general, method validation involves method scope, calibration-related parameters, method precision, and recovery. Any method change which may affect method scope or any performance parameters will require re-validation. Some typical situations involving change in methods are discussed and a decision process proposed for selection of appropriate validation measures. © 2012 John Wiley & Sons, Ltd.

  8. Quantification of endocrine disruptors and pesticides in water by gas chromatography-tandem mass spectrometry. Method validation using weighted linear regression schemes.

    PubMed

    Mansilha, C; Melo, A; Rebelo, H; Ferreira, I M P L V O; Pinho, O; Domingues, V; Pinho, C; Gameiro, P

    2010-10-22

    A multi-residue methodology based on a solid phase extraction followed by gas chromatography-tandem mass spectrometry was developed for trace analysis of 32 compounds in water matrices, including estrogens and several pesticides from different chemical families, some of them with endocrine disrupting properties. Matrix standard calibration solutions were prepared by adding known amounts of the analytes to a residue-free sample to compensate matrix-induced chromatographic response enhancement observed for certain pesticides. Validation was done mainly according to the International Conference on Harmonisation recommendations, as well as some European and American validation guidelines with specifications for pesticides analysis and/or GC-MS methodology. As the assumption of homoscedasticity was not met for analytical data, weighted least squares linear regression procedure was applied as a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line, improving accuracy at the lower end of the calibration curve. The method was considered validated for 31 compounds after consistent evaluation of the key analytical parameters: specificity, linearity, limit of detection and quantification, range, precision, accuracy, extraction efficiency, stability and robustness. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. [Determination of 250 pesticide residues in vegetables using QuEChERS-ultra performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhang, Aizhi; Wang, Quanlin; Cao, Lili; Li, Yu; Shen, Hao; Shen, Jian; Zhang, Shufen; Man, Zhengyin

    2016-02-01

    A multiresidue analytical method for the determination of 250 pesticide residues in vegetables was developed by using QuEChERS-ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The target compounds were extracted with acetonitrile containing 1% (v/v) acetic acid, purified by a mixed sorbent of MgSO4, primary secondary amine (PSA), graphitized carbon black (GCB) and C18, separated on a Waters ACQUITY™ UPLC BEH C18 column (100 mm x 2. 1 mm, 1.7 µm) and detected by UPLC-MS/MS. Anhydrous magnesium sulfate was used as a dewatering agent. The effects of the amounts of MgSO4, PSA, GCB and C18 added on the recoveries of 250 pesticides were investigated. The results showed that the purification effect was best when 300 mg MgSO4, 200 mg PSA, 10 mg GCB and 100 mg C18 in 2 mL of the extract were added. For the 250 pesticide residues, the limits of detection (LODs) of the method were from 0. 01 to 50. 00 g/kg. The recoveries obtained ranged from 60. 1% to 120% at three spiked levels in Chinese chives with the relative standard deviations between 3. 5% and 19. 5% using matrix matched external standard method. The results showed that the method is able to meet requirements of the multiresidue detection of the 250 pesticides in vegetable. The method has the advantages of rapidity, simplicity, high sensitivity and better purification effect. It is suitable for the rapid determination of the common pesticides in vegetables, and it provides a strong guarantee for the risk assessments of the quality and safety of vegetables.

  10. Multiresidue analysis of sulfonamides in meat by supramolecular solvent microextraction, liquid chromatography and fluorescence detection and method validation according to the 2002/657/EC decision.

    PubMed

    Costi, Esther María; Sicilia, María Dolores; Rubio, Soledad

    2010-10-01

    A multiresidue method was described for determining eight sulfonamides, SAs (sulfadiazine, sulfamerazine, sulfamethoxypyridazine, sulfachloropyridazine, sulfadoxine, sulfamethoxazole, sulfadimethoxine and sulfaquinoxaline) in animal muscle tissues (pork, chicken, turkey, lamb and beef) at concentrations below the maximum residue limit (100 μg kg(-1)) set by the European Commission. The method was based on the microextraction of SAs in 300-mg muscle samples with 1 mL of a supramolecular solvent made up of reverse micelles of decanoic acid (DeA) and posterior determination of SAs in the extract by LC/fluorescence detection, after in situ derivatization with fluorescamine. Recoveries were quantitative (98-109%) and matrix-independent, no concentration of the extracts was required, the microextraction took about 30 min and several samples could be simultaneously treated. Formation of multiple hydrogen bonds between the carboxylic groups of the solvent and the target SAs (hydrogen donor and acceptor sum between 9 and 11) were considered as the major forces driving microextraction. The method was validated according to the European Union regulation 2002/657/EC. Analytical performance in terms of linearity, selectivity, trueness, precision, stability of SAs, decision limit and detection capability were determined. Quantitation limits for the different SAs ranged between 12 μg kg(-1) and 44 μg kg(-1), they being nearly independent of matrix composition. Repeatability and reproducibility, expressed as relative standard deviation, were in the ranges 1.8-3.6% and 3.3-6.1%. The results of the validation process proved that the method is suitable for determining sulfonamide residues in surveillance programs. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Multiresidue analysis of endocrine-disrupting compounds and perfluorinated sulfates and carboxylic acids in sediments by ultra-high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Cavaliere, Chiara; Capriotti, Anna Laura; Ferraris, Francesca; Foglia, Patrizia; Samperi, Roberto; Ventura, Salvatore; Laganà, Aldo

    2016-03-18

    A multiresidue analytical method for the determination of 11 perfluorinated compounds and 22 endocrine-disrupting compounds (ECDs) including 13 natural and synthetic estrogens (free and conjugated forms), 2 alkylphenols, 1 plasticiser, 2 UV-filters, 1 antimicrobial, and 2 organophosphorus compounds in sediments has been developed. Ultrasound-assisted extraction followed by solid phase extraction (SPE) with graphitized carbon black (GCB) cartridge as clean-up step were used. The extraction process yield was optimized in terms of solvent composition. Then, a 3(2) experimental design was used to optimize solvent volume and sonication time by response surface methodology, which simplifies the optimization procedure. The final extract was analyzed by ultra-high performance liquid chromatography coupled with tandem mass spectrometry. The optimized sample preparation method is simple and robust, and allows recovery of ECDs belonging to different classes in a complex matrix such as sediment. The use of GCB for SPE allowed to obtain with a single clean-up procedure excellent recoveries ranging between 75 and 110% (relative standard deviation <16%). The developed methodology has been successfully applied to the analysis of ECDs in sediments from different rivers and lakes of the Lazio Region (Italy). These analyses have shown the ubiquitous presence of chloro-substituted organophosphorus flame retardants and bisphenol A, while other analyzed compounds were occasionally found at concentration between the limit of detection and quantification. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Multi-residue method for the determination of 450 pesticide residues in honey, fruit juice and wine by double-cartridge solid-phase extraction/gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry.

    PubMed

    Pang, G-F; Fan, C-L; Liu, Y-M; Cao, Y-Z; Zhang, J-J; Fu, B-L; Li, X-M; Li, Z-Y; Wu, Y-P

    2006-08-01

    A multi-residue method was developed for the determination of 450 pesticide residues in honey, fruit juice and wine using double-cartridge solid-phase extraction (SPE), gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS). The method development was based on an appraisal of the characteristics of GC-MS and LC-MS-MS for 654 pesticides as well as the efficiency of extraction and purification from honey, fruit juice and wine. Samples were first diluted with water plus acetone, then extracted with portions of dichloromethane. The extracts were concentrated and cleaned up with graphitized carbon black and aminopropyl cartridges stacked in tandem. Pesticides were eluted with acetonitrile + toluene, and the eluates were concentrated. For 383 pesticides, the eluate was extracted with hexane twice and internal standard solution was added prior to GC-MS determination. For 67 pesticides, extraction was with methanol prior to LC-MS-MS determination. The limit of detection for the method was between 1.0 and 300 ng g(-1) depending on each pesticide analyte. At the three fortification levels of 2.0-3000 ng g(-1), the average recovery rates were between 59 and 123%, among which 413 pesticides (92% of the 450) had recovery rates of 70-120% and 35 pesticides (8% of the 450) had recovery rates of 59-70%. There were 437 pesticides (97% of the 450) with a relative standard deviation below 25%; there were 13 varieties (3% of the 450) between 25.0 and 30.4%.

  13. Identification and measurement of beta-lactam antibiotic residues in milk: integration of screening kits with liquid chromatography.

    PubMed

    Harik-Khan, R; Moats, W A

    1995-01-01

    A procedure for identifying and quantitating violative beta-lactams in milk is described. This procedure integrates beta-lactam residue detection kits with the multiresidue automated liquid chromatographic (LC) cleanup method developed in our laboratory. Spiked milk was deproteinized, extracted, and subjected to reversed-phase LC using a gradient program that concentrated the beta-lactams. Amoxicillin, ampicillin, cephapirin, ceftiofur, cloxacillin, and penicillin G were, thus, separated into 5 fractions that were subsequently tested for activity by using 4 kits. beta-lactams in the positive fractions were quantitated by analytical LC methods developed in our laboratory. The LC cleanup method separated beta-lactam antibiotics from each other and from interferences in the matrix and also concentrated the antibiotics, thus increasing the sensitivity of the kits to the beta-lactam antibiotics. The procedure facilitated the task of identifying and measuring the beta-lactam antibiotics that may be present in milk samples.

  14. Analytical method for fast screening and confirmation of multi-class veterinary drug residues in fish and shrimp by LC-MS/MS.

    PubMed

    Kim, Junghyun; Suh, Joon Hyuk; Cho, Hyun-Deok; Kang, Wonjae; Choi, Yong Seok; Han, Sang Beom

    2016-01-01

    A multi-class, multi-residue analytical method based on LC-MS/MS detection was developed for the screening and confirmation of 28 veterinary drug and metabolite residues in flatfish, shrimp and eel. The chosen veterinary drugs are prohibited or unauthorised compounds in Korea, which were categorised into various chemical classes including nitroimidazoles, benzimidazoles, sulfones, quinolones, macrolides, phenothiazines, pyrethroids and others. To achieve fast and simultaneous extraction of various analytes, a simple and generic liquid extraction procedure using EDTA-ammonium acetate buffer and acetonitrile, without further clean-up steps, was applied to sample preparation. The final extracts were analysed by ultra-high-performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS). The method was validated for each compound in each matrix at three different concentrations (5, 10 and 20 ng g(-1)) in accordance with Codex guidelines (CAC/GL 71-2009). For most compounds, the recoveries were in the range of 60-110%, and precision, expressed as the relative standard deviation (RSD), was in the range of 5-15%. The detection capabilities (CCβs) were below or equal to 5 ng g(-1), which indicates that the developed method is sufficient to detect illegal fishery products containing the target compounds above the residue limit (10 ng g(-1)) of the new regulatory system (Positive List System - PLS).

  15. Modification and re-validation of the ethyl acetate-based multi-residue method for pesticides in produce

    PubMed Central

    Rooseboom, Astrid; van Dam, Ruud; Roding, Marleen; Arondeus, Karin; Sunarto, Suryati

    2007-01-01

    The ethyl acetate-based multi-residue method for determination of pesticide residues in produce has been modified for gas chromatographic (GC) analysis by implementation of dispersive solid-phase extraction (using primary–secondary amine and graphitized carbon black) and large-volume (20 μL) injection. The same extract, before clean-up and after a change of solvent, was also analyzed by liquid chromatography with tandem mass spectrometry (LC–MS–MS). All aspects related to sample preparation were re-assessed with regard to ease and speed of the analysis. The principle of the extraction procedure (solvent, salt) was not changed, to avoid the possibility invalidating data acquired over past decades. The modifications were made with techniques currently commonly applied in routine laboratories, GC–MS and LC–MS–MS, in mind. The modified method enables processing (from homogenization until final extracts for both GC and LC) of 30 samples per eight hours per person. Limits of quantification (LOQs) of 0.01 mg kg−1 were achieved with both GC–MS (full-scan acquisition, 10 mg matrix equivalent injected) and LC–MS–MS (2 mg injected) for most of the pesticides. Validation data for 341 pesticides and degradation products are presented. A compilation of analytical quality-control data for pesticides routinely analyzed by GC–MS (135 compounds) and LC–MS–MS (136 compounds) in over 100 different matrices, obtained over a period of 15 months, are also presented and discussed. At the 0.05 mg kg−1 level acceptable recoveries were obtained for 93% (GC–MS) and 92% (LC–MS–MS) of pesticide–matrix combinations. PMID:17563885

  16. Multiresidue analysis of oestrogenic compounds in cow, goat, sheep and human milk using core-shell polydopamine coated magnetic nanoparticles as extraction sorbent in micro-dispersive solid-phase extraction followed by ultra-high-performance liquid chromatography tandem mass spectrometry.

    PubMed

    Socas-Rodríguez, Bárbara; Hernández-Borges, Javier; Herrera-Herrera, Antonio V; Rodríguez-Delgado, Miguel Ángel

    2018-03-01

    In this work, the suitability of Fe 3 O 4 nanoparticles coated with polydopamine was evaluated as sorbent for the extraction of a group of 21 compounds with oestrogenic activity including seven phytoestrogens, six mycotoxins as well as four synthetic and four natural oestrogens from different types of milk, including sheep milk, in which the evaluation of oestrogenic compounds have never been developed before. Extraction was carried out using magnetic micro-dispersive solid-phase extraction after a previous deproteinisation step. Separation, determination and quantification of the target analytes were achieved by ultra-high-performance liquid chromatography coupled to triple quadrupole-tandem mass spectrometry. The methodology was validated for five milk samples using 17β-estradiol-2,4,16,16,17-d 5 as internal standard for natural and synthetic oestrogens, β-zearalanol-10,10,11,12,12-d 5 for mycotoxins and prunetin for phytoestrogens. Recovery values ranged from 70 to 120% for the five types of matrices with relative standard deviation values lower than 18%. Limits of quantification of the method were in the range 0.55-11.8 μg L -1 for all samples. Graphical abstract General scheme of the multiresidue analysis of oestrogenic compounds in milk using core-shell polydopamine coated magnetic nanoparticles as extraction sorbent in μ-dSPE.

  17. Multiresidue analytical method using dispersive solid-phase extraction and gas chromatography/ion trap mass spectrometry to determine pharmaceuticals in whole blood.

    PubMed

    Plössl, Florian; Giera, Martin; Bracher, Franz

    2006-11-24

    A convenient analytical method for the simultaneous determination of more than 40 pharmaceuticals belonging to various therapeutic categories in whole blood has been developed. Exemplarily, the method was fully validated for eight different pharmaceuticals. The procedure entails addition of acetonitrile, magnesium sulfate and sodium chloride to a small amount of blood, then the mixture is shaken intensively and centrifuged for phase separation. An aliquot of the organic layer is cleaned up by dispersive solid-phase extraction employing bulk sorbents as well as magnesium sulfate for the removal of residual water. This method was based on the QuEChERS approach developed for pesticide residue analysis in food. Gas chromatography/ion trap mass spectrometry (GC/MS) with electron (EI) and chemical (CI) ionisation was then used for qualitative and quantitative determination of the pharmaceuticals. The dispersive SPE with PSA (sorbent functionalized with primary and secondary amines) was found more suitable than aminopropyl and a styrene-divinylbenzene sorbent for sample clean-up before drug level determination in whole blood and plasma, as it was found that most of endogenous matrix components were removed and the analytes were isolated from spiked samples with recoveries above 80%. Variation coefficients of the repeatability typically smaller than 10% have been achieved for a wide range of the investigated substances. The used analytical conditions allowed to separate successively a variety of drugs and poisons with the typical limit of detection at <20 ng mL(-1) levels using 1 microL injection of equivalent blood sample in whole blood. The method is simple, rapid, cheap and very effective for therapeutic drug monitoring and forensic chemistry.

  18. Development and application of a multi-residue method for the determination of 53 pharmaceuticals in water, sediment, and suspended solids using liquid chromatography-tandem mass spectrometry.

    PubMed

    Aminot, Yann; Litrico, Xavier; Chambolle, Mélodie; Arnaud, Christine; Pardon, Patrick; Budzindki, Hélène

    2015-11-01

    Comprehensive source and fate studies of pharmaceuticals in the environment require analytical methods able to quantify a wide range of molecules over various therapeutic classes, in aqueous and solid matrices. Considering this need, the development of an analytical method to determine 53 pharmaceuticals in aqueous phase and in solid matrices using a combination of microwave-assisted extraction, solid phase extraction, and liquid chromatography coupled with tandem mass spectrometry is reported. Method was successfully validated regarding linearity, repeatability, and overall protocol recovery. Method detection limits (MDLs) do not exceed 1 ng L(-1) for 40 molecules in aqueous matrices (6 ng L(-1) for the 13 remaining), while subnanogram per gram MDLs were reached for 38 molecules in solid phase (29 ng g(-1) for the 15 remaining). Losses due to preparative steps were assessed for the 32 analytes associated to their labeled homologue, revealing an average loss of 40 % during reconcentration, the most altering step. Presence of analytes in wastewater treatment plant (WWTP) effluent aqueous phase and suspended solids (SS) as well as in river water, SS, and sediments was then investigated on a periurban river located in the suburbs of Bordeaux, France, revealing a major contribution of WWTP effluent to the river contamination. Sorption on river SS exceeded 5 % of total concentration for amitriptyline, fluoxetine, imipramine, ritonavir, sildenafil, and propranolol and appeared to be submitted to a seasonal influence. Sediment contamination was lower than the one of SS, organic carbon content, and sediment fine element proportion was accountable for the highest measured concentrations.

  19. Multi-residue analysis of organic pollutants in hair and urine for matrices comparison.

    PubMed

    Hardy, Emilie M; Duca, Radu C; Salquebre, Guillaume; Appenzeller, Brice M R

    2015-04-01

    Urine being currently the most classically used matrix for the assessment of human exposure to pesticides, a growing interest is yet observed in hair analysis for the detection of organic pollutants. The aim of the present work was to develop and to validate multi-residue analytical methods, as similar as possible, in order to determine pesticides and their metabolites in these two biological matrices despite their different nature. The list of parent compounds and their metabolites investigated here consisted of 56 compounds, including organochlorines, organophosphates, pyrethroids, carbamates, other pesticides and polychlorinated biphenyls (PCBs). Two different approaches were necessary for the analysis of non-polar compounds (mainly parents) on one hand and polar analytes (mainly metabolites) on the other hand. In the final procedure, extraction from hair was carried out with acetonitrile/water after sample decontamination and pulverization. Extract was split into two fractions, which were analyzed directly with solid phase microextraction (SPME) injection for non-polar compounds and after derivatization with liquid injection for polar compounds. In urine, non-polar compounds were analyzed directly using SPME. Polar compounds were analyzed after acidic hydrolysis, liquid-liquid extraction with acetonitrile-cyclohexane-ethyl acetate, derivatization and liquid injection. Analysis was performed with gas chromatography tandem mass spectrometry operating in negative chemical ionization (GC-MS/MS-NCI) for all the compounds (non-polar and polar) in the two matrices. In hair, limits of quantification (LOQ) ranged from 0.02 pg/mg for trifluralin to 5.5 pg/mg for diethylphosphate. In urine, LOQ ranged from 0.4 pg/mL for α-endosulfan to 4 ng/mL for dimethyldithiophosphate. The analysis of samples supplemented with standards and samples collected from an animal previously submitted to chronic exposure to pesticides confirmed that all the compounds were analyzable in both hair and urine. In addition, the levels of sensitivity reached with these methods were quite satisfactory with regard to previously published studies, and also considering the number of compounds investigated. Copyright © 2014. Published by Elsevier Ireland Ltd.

  20. Quantitative on-line preconcentration-liquid chromatography coupled with tandem mass spectrometry method for the determination of pharmaceutical compounds in water.

    PubMed

    Idder, Salima; Ley, Laurent; Mazellier, Patrick; Budzinski, Hélène

    2013-12-17

    One of the current environmental issues concerns the presence and fate of pharmaceuticals in water bodies as these compounds may represent a potential environmental problem. The characterization of pharmaceutical contamination requires powerful analytical method able to quantify these pollutants at very low concentration (few ng L(-1)). In this work, a multi-residue analytical methodology (on-line solid phase extraction-liquid chromatography-triple quadrupole mass spectrometry using positive and negative electrospray ionization) has been developed and validated for 40 multi-class pharmaceuticals and metabolites for tap and surface waters. This on-line SPE method was very convenient and efficient compared to classical off-line SPE method because of its shorter total run time including sample preparation and smaller sample volume (1 mL vs up to 1 L). The optimized method included several therapeutic classes as lipid regulators, antibiotics, beta-blockers, non-steroidal anti-inflammatories, antineoplastic, etc., with various physicochemical properties. Quantification has been achieved with the internal standards. The limits of detection are between 0.7 and 15 ng L(-1) for drinking waters and 2-15 ng L(-1) for surface waters. The inter-day precision values are below 20% for each studied level. The improvement and strength of the analytical method has been verified along a monitoring of these 40 pharmaceuticals in Isle River, a French stream located in the South West of France. During this survey, 16 pharmaceutical compounds have been detected. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Multi-residue determination of the sorption of illicit drugs and pharmaceuticals to wastewater suspended particulate matter using pressurised liquid extraction, solid phase extraction and liquid chromatography coupled with tandem mass spectrometry.

    PubMed

    Baker, David R; Kasprzyk-Hordern, Barbara

    2011-11-04

    Presented is the first comprehensive study of drugs of abuse on suspended particulate matter (SPM) in wastewater. Analysis of SPM is crucial to prevent the under-reporting of the levels of analyte that may be present in wastewater. Analytical methods to date analyse the aqueous part of wastewater samples only, removing SPM through the use of filtration or centrifugation. The development of an analytical method to determine 60 compounds on SPM using a combination of pressurised liquid extraction, solid phase extraction and liquid chromatography coupled with tandem mass spectrometry (PLE-SPE-LC-MS/MS) is reported. The range of compounds monitored included stimulants, opioid and morphine derivatives, benzodiazepines, antidepressants, dissociative anaesthetics, drug precursors, and their metabolites. The method was successfully validated (parameters studied: linearity and range, recovery, accuracy, reproducibility, repeatability, matrix effects, and limits of detection and quantification). The developed methodology was applied to SPM samples collected at three wastewater treatment plants in the UK. The average proportion of analyte on SPM as opposed to in the aqueous phase was <5% for several compounds including cocaine, benzoylecgonine, MDMA, and ketamine; whereas the proportion was >10% with regard to methadone, EDDP, EMDP, BZP, fentanyl, nortramadol, norpropoxyphene, sildenafil and all antidepressants (dosulepin, amitriptyline, nortriptyline, fluoxetine and norfluoxetine). Consequently, the lack of SPM analysis in wastewater sampling protocol could lead to the under-reporting of the measured concentration of some compounds. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Multi-residue analysis of 36 priority and emerging pollutants in marine echinoderms (Holothuria tubulosa) and marine sediments by solid-liquid extraction followed by dispersive solid phase extraction and liquid chromatography-tandem mass spectrometry analysis.

    PubMed

    Martín, J; Zafra-Gómez, A; Hidalgo, F; Ibáñez-Yuste, A J; Alonso, E; Vilchez, J L

    2017-05-01

    Marine echinoderms are filter-feeding invertebrates widely distributed along the coasts, and which are therefore extensively exposed to anthropogenic xenobiotics. They can serve as good sentinels for monitoring a large variety of contaminants in marine ecosystems. In this context, a multi-residue analytical method has been validated and applied to Holothuria tubulosa specimens and marine sediments for the determination of 36 organic compounds, which belong to some of the most problematic groups of emerging and priority pollutants (perfluoroalkyl compounds, estrogens, parabens, benzophenones, plasticizers, surfactants, brominated flame retardants and alkylphenols). Lyophilization of samples prior to solvent extraction and clean-up of extracts with C18, followed by liquid chromatography-tandem mass spectrometry analysis, is proposed. A Box-Behnken design was used for optimization of the most influential variables affecting the extraction and clean-up steps. For validation, matrix-matched calibration and recovery assay were applied. Linearity (% r 2 ) higher than 99%, recoveries between 80% and 114% (except in LAS and NP1EO), RSD (precision) lower than 15% and limits of quantification between 0.03 and 12.5ngg -1 dry weight (d.w.) were achieved. The method was applied to nine samples of Holothuria collected along the coast of Granada (Spain), and to marine sediments around the animals. The results demonstrated high bioaccumulation of certain pollutants. A total of 25 out of the 36 studied compounds were quantified, being surfactants, alkylphenols, perfluoroalkyl compounds, triclocarban and parabens the most frequently detected. Nonylphenol was found in the highest concentration (340 and 323ngg -1 d.w. in sediment and Holothuria samples, respectively). Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Determination of multiresidues of three acid herbicides in tobacco by liquid chromatography/tandem mass spectrometry.

    PubMed

    Liu, Shanshan; Bian, Zhaoyang; Yang, Fei; Li, Zhonghao; Fan, Ziyan; Zhang, Hongfei; Wang, Ying; Zhang, Yange; Tang, Gangling

    2015-01-01

    A method to determine residues of the three acid herbicides, 2,4,5-trichlorophenoxyacetic acid, 2,4-dichlorophenoxyacetic acid, and 3,6-dichloro-2-methoxybenzoic acid (dicamba), in tobacco using LC/MS/MS is presented. Because these herbicide residues in tobacco might exist in different forms (free acid, salt, and ester), tobacco samples were first pretreated by alkaline hydrolysis and then the pH was adjusted in order to convert the residues completely to their free acid forms. Dichloromethane extraction and dispersive SPE using C18 sorbent were carried out before LC/MS/MS analysis, and quantification was performed using the internal standard method. Linearity was good for all analytes (R(2) ≥ 0.999) in the concentration range of 0.02 to 0.5 mg/kg. LODs were below 0.05 mg/kg. Recoveries ranged from 80.4 to 93.5%, and RSD was below 10%. This simple, efficient, and sensitive method can be applied to the determination of residues of the three acid herbicides in tobacco.

  4. 77 FR 25954 - Receipt of Several Pesticide Petitions Filed for Residues of Pesticide Chemicals in or on Various...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-02

    ... commodities. These methods include: Gas-Liquid Chromatography ((GLC)--Method I in PAM II); HPLC with... methodology for proquinazid in plant- based matrices is the DFG-S19 multi-residue method which uses gas...

  5. Bee pollen as a bioindicator of environmental pesticide contamination.

    PubMed

    de Oliveira, Renata Cabrera; Queiroz, Sonia Claudia do Nascimento; da Luz, Cynthia Fernandes Pinto; Porto, Rafael Silveira; Rath, Susanne

    2016-11-01

    Honeybees and bee products are potential bioindicators of the presence of contaminants in the environment, enabling monitoring of large areas due to the long distances travelled by bees. This work evaluates the use of bee pollen as a bioindicator of environmental contamination by pesticides. A GC-MS/MS analytical method for multiresidue determination of 26 different pesticides in pollen was developed and validated in accordance with the recommendations of the European Union SANCO guide. Environmental monitoring was conducted using the analysis of 145 pollen samples collected from ten beehives in the experimental apiary of Embrapa in Jaguariúna (São Paulo State, Brazil). Bioallethrin and pendimethalin were identified in four and eighteen samples, respectively, at concentrations below the LOQ of the method (25 ng g(-1)). Passive sampling with polyurethane foam discs was used as a control, and no pesticides were found. The detection of pesticide residues in seven samples (33%) from commercial apiaries in Ribeirão Preto (São Paulo State) confirmed the efficiency of the analytical method and the need for environmental monitoring for the presence of pesticide residues. The results demonstrated the potential of bee pollen as a bioindicator of environmental contamination by pesticides. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Multi-residue determination of 115 veterinary drugs and pharmaceutical residues in milk powder, butter, fish tissue and eggs using liquid chromatography-tandem mass spectrometry.

    PubMed

    Dasenaki, Marilena E; Thomaidis, Nikolaos S

    2015-06-23

    A simple and sensitive multi-residue method for the determination of 115 veterinary drugs and pharmaceuticals, belonging in more than 20 different classes, in butter, milk powder, egg and fish tissue has been developed. The method involves a simple generic solid-liquid extraction step (solvent extraction, SE) with 0.1% formic acid in aqueous solution of EDTA 0.1% (w/v)-acetonitrile (ACN)-methanol (MeOH) (1:1:1, v/v) with additional ultrasonic-assisted extraction. Precipitation of lipids and proteins was promoted by subjecting the extracts at very low temperature (-23°C) for 12h. Further cleanup with hexane ensures fat removal from the matrix. Analysis was performed by liquid chromatography coupled with electrospray ionization and tandem mass spectrometry (LC-ESI-MS/MS). Two separate runs were performed for positive and negative ionization in multiple reaction monitoring mode (MRM). Particular attention was devoted to extraction optimization: different sample-to-extracting volume ratios, different concentrations of formic acid in the extraction solvent and different ultrasonic extraction temperatures were tested in butter, egg and milk powder samples. The method was also applied in fish tissue samples. It was validated, on the basis of international guidelines, for all four matrices. Quantitative analysis was performed by means of standard addition calibration. For over 80% of the analytes, the recoveries were between 50% and 120% in all matrices studied, with RSD values in the range of 1-18%. Limits of detection (LODs) and quantification (LOQs) ranged from 0.008 μg kg(-1) (oxfendazole in butter) to 3.15 μg kg(-1) (hydrochlorthiazide in egg). The evaluated method provides reliable screening, quantification, and identification of 115 veterinary drug and pharmaceutical residues in foods of animal origin and has been successfully applied in real samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Rapid determination of residues of pesticides in honey by µGC-ECD and GC-MS/MS: Method validation and estimation of measurement uncertainty according to document No. SANCO/12571/2013.

    PubMed

    Paoloni, Angela; Alunni, Sabrina; Pelliccia, Alessandro; Pecorelli, Ivan

    2016-01-01

    A simple and straightforward method for simultaneous determination of residues of 13 pesticides in honey samples (acrinathrin, bifenthrin, bromopropylate, cyhalothrin-lambda, cypermethrin, chlorfenvinphos, chlorpyrifos, coumaphos, deltamethrin, fluvalinate-tau, malathion, permethrin and tetradifon) from different pesticide classes has been developed and validated. The analytical method provides dissolution of honey in water and an extraction of pesticide residues by n-Hexane followed by clean-up on a Florisil SPE column. The extract was evaporated and taken up by a solution of an injection internal standard (I-IS), ethion, and finally analyzed by capillary gas chromatography with electron capture detection (GC-µECD). Identification for qualitative purpose was conducted by gas chromatography with triple quadrupole mass spectrometer (GC-MS/MS). A matrix-matched calibration curve was performed for quantitative purposes by plotting the area ratio (analyte/I-IS) against concentration using a GC-µECD instrument. According to document No. SANCO/12571/2013, the method was validated by testing the following parameters: linearity, matrix effect, specificity, precision, trueness (bias) and measurement uncertainty. The analytical process was validated analyzing blank honey samples spiked at levels equal to and greater than 0.010 mg/kg (limit of quantification). All parameters were satisfactorily compared with the values established by document No. SANCO/12571/2013. The analytical performance was verified by participating in eight multi-residue proficiency tests organized by BIPEA, obtaining satisfactory z-scores in all 70 determinations. Measurement uncertainty was estimated according to the top-down approaches described in Appendix C of the SANCO document using the within-laboratory reproducibility relative standard deviation combined with laboratory bias using the proficiency test data.

  8. Analytical methods for the assessment of endocrine disrupting chemical exposure during human fetal and lactation stages: a review.

    PubMed

    Jiménez-Díaz, I; Vela-Soria, F; Rodríguez-Gómez, R; Zafra-Gómez, A; Ballesteros, O; Navalón, A

    2015-09-10

    In the present work, a review of the analytical methods developed in the last 15 years for the determination of endocrine disrupting chemicals (EDCs) in human samples related with children, including placenta, cord blood, amniotic fluid, maternal blood, maternal urine and breast milk, is proposed. Children are highly vulnerable to toxic chemicals in the environment. Among these environmental contaminants to which children are at risk of exposure are EDCs -substances able to alter the normal hormone function of wildlife and humans-. The work focuses mainly on sample preparation and instrumental techniques used for the detection and quantification of the analytes. The sample preparation techniques include, not only liquid-liquid extraction (LLE) and solid-phase extraction (SPE), but also modern microextraction techniques such as extraction with molecular imprinted polymers (MIPs), stir-bar sorptive extraction (SBSE), hollow-fiber liquid-phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME), matrix solid phase dispersion (MSPD) or ultrasound-assisted extraction (UAE), which are becoming alternatives in the analysis of human samples. Most studies focus on minimizing the number of steps and using the lowest solvent amounts in the sample treatment. The usual instrumental techniques employed include liquid chromatography (LC), gas chromatography (GC) mainly coupled to tandem mass spectrometry. Multiresidue methods are being developed for the determination of several families of EDCs with one extraction step and limited sample preparation. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Validation of an UHPLC-MS/MS Method for Screening of Antimicrobial Residues in Eggs and Their Application to Analyses of Eggs from Laying Hens Subjected to Pharmacological Treatment

    PubMed Central

    Caldeira, Letícia Gomes Magnago; Santos, Flávio Alves; de Oliveira, Andréa Melo Garcia; Lima, Josefa Abucater; de Souza, Leonardo Francisco; da Silva, Guilherme Resende; de Assis, Débora Cristina Sampaio

    2017-01-01

    A multiresidue method by UHPLC/MS-MS was optimized and validated for the screening and semiquantitative detection of antimicrobials residues from tetracyclines, aminoglycosides, quinolones, lincosamides, β-lactams, sulfonamides, and macrolides families in eggs. A qualitative approach was used to ensure adequate sensitivity to detect residues at the level of interest, defined as maximum residue limit (MRL), or less. The applicability of the methods was assessed by analyzing egg samples from hens that had been subjected to pharmacological treatment with neomycin, enrofloxacin, lincomycin, oxytetracycline, and doxycycline during five days and after discontinuation of medication (10 days). The method was adequate for screening all studied analytes in eggs, since the performance parameters ensured a false-compliant rate below or equal to 5%, except for flumequine. In the analyses of eggs from laying hens subjected to pharmacological treatment, all antimicrobial residues were detected throughout the experimental period, even after discontinuation of medication, except for neomycin, demonstrating the applicability of the method for analyses of antimicrobial residues in eggs. PMID:29181222

  10. Compensation of matrix effects in gas chromatography-mass spectrometry analysis of pesticides using a combination of matrix matching and multiple isotopically labeled internal standards.

    PubMed

    Tsuchiyama, Tomoyuki; Katsuhara, Miki; Nakajima, Masahiro

    2017-11-17

    In the multi-residue analysis of pesticides using GC-MS, the quantitative results are adversely affected by a phenomenon known as the matrix effect. Although the use of matrix-matched standards is considered to be one of the most practical solutions to this problem, complete removal of the matrix effect is difficult in complex food matrices owing to their inconsistency. As a result, residual matrix effects can introduce analytical errors. To compensate for residual matrix effects, we have developed a novel method that employs multiple isotopically labeled internal standards (ILIS). The matrix effects of ILIS and pesticides were evaluated in spiked matrix extracts of various agricultural commodities, and the obtained data were subjected to simple statistical analysis. Based on the similarities between the patterns of variation in the analytical response, a total of 32 isotopically labeled compounds were assigned to 338 pesticides as internal standards. It was found that by utilizing multiple ILIS, residual matrix effects could be effectively compensated. The developed method exhibited superior quantitative performance compared with the common single-internal-standard method. The proposed method is more feasible for regulatory purposes than that using only predetermined correction factors and is considered to be promising for practical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. A confirmatory method for the simultaneous extraction, separation, identification and quantification of Tetracycline, Sulphonamide, Trimethoprim and Dapsone residues in muscle by ultra-high-performance liquid chromatography-tandem mass spectrometry according to Commission Decision 2002/657/EC.

    PubMed

    McDonald, Mark; Mannion, Celine; Rafter, Paul

    2009-11-13

    A rapid confirmatory multi-residue method for the analysis of tetracyclines, sulphonamides, trimethoprim and dapsone by UPLC-MS/MS is described. The method is able to quantify and confirm the following 19 compounds, oxytetracycline, tetracycline, chlortetracycline, doxycycline, sulfadiazine, sulfathiazole, sulfapyridine, trimethoprim, sulfamerazine, sulfamethizole, sulfamethazine, sulfamethoxypyridazine, sulfamonomethoxine, sulfachlorpyridazine, dapsone, sulfamethoxazole, sulfisoxazole, sulfaquinoxaline and sulfadimethoxine. Samples are extracted with 0.1M EDTA and acetonitrile, which is then evaporated under a stream of nitrogen and reconstituted in water. Following centrifugation and filtering, an aliquot is analysed by UPLC-MS/MS using positive electrospray ionisation and multiple reaction monitoring. The method is deemed rapid as all analytes are extracted by a single extraction technique, with no solid-phase extraction clean up required. Validation is according to Commission Decision 2002/657/EC and was carried out for bovine, porcine, ovine and poultry species. Specificity, recovery, repeatability, reproducibility, CCalpha and CCbeta data is presented.

  12. Multiresidue method for the determination of pesticides in Oolong tea using QuEChERS by gas chromatography-triple quadrupole tandem mass spectrometry.

    PubMed

    Wu, Chia-Chang

    2017-08-15

    We propose a simple, rapid analytical method for determination of 89 pesticides in Oolong tea by GC/MS/MS. Samples were extracted via QuEChERS. The limits of detection and quantification range of the 89 pesticides were 1-25μgL -1 and 10-50μgL -1 , respectively. Good separation was attained in less than 36min. A wide linear range of 1-250μgL -1 was observed with r 2 values from 0.9955 to 0.9998. Pesticide-free tea powder spiked at 50 and 100μgL -1 . Recovery ranges of the 86 (50μgL -1 ) and 83 (100μgL -1 ) pesticides were from 60% to 120%. Relative standard deviations were less than 20%. The laboratory proficiency test (FAPAS, 2014) shows satisfactory (|z|<2) z-score values. The proposed monitoring technique rapidly and efficiently screens, multiple pesticides in Oolong tea. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Multiresidue analysis of acidic and polar organic contaminants in water samples by stir-bar sorptive extraction-liquid desorption-gas chromatography-mass spectrometry.

    PubMed

    Quintana, José Benito; Rodil, Rosario; Muniategui-Lorenzo, Soledad; López-Mahía, Purificación; Prada-Rodríguez, Darío

    2007-12-07

    The feasibility of stir-bar sorptive extraction (SBSE) followed by liquid desorption in combination with large volume injection (LVI)-in port silylation and gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of a broad range of 46 acidic and polar organic pollutants in water samples has been evaluated. The target analytes included phenols (nitrophenols, chlorophenols, bromophenols and alkylphenols), acidic herbicides (phenoxy acids and dicamba) and several pharmaceuticals. Experimental variables affecting derivatisation yield and peak shape as a function of different experimental PTV parameters [initial injection time, pressure and temperature and the ratio solvent volume/N-(tert-butyldimethylsilyl)-N-methyltrifluoroacetamide (MTBSTFA) volume] were first optimised by an experimental design approach. Subsequently, SBSE conditions, such as pH, ionic strength, agitation speed and extraction time were investigated. After optimisation, the method failed only for the extraction of most polar phenols and some pharmaceuticals, being suitable for the determination of 37 (out of 46) pollutants, with detection limits for these analytes ranging between 1 and 800 ng/L and being lower than 25 ng/L in most cases. Finally, the developed method was validated and applied to the determination of target analytes in various aqueous environmental matrices, including ground, river and wastewater. Acceptable accuracy (70-130%) and precision values (<20%) were obtained for most analytes independently of the matrix, with the exception of some alkylphenols, where an isotopically labelled internal standard would be required in order to correct for matrix effects. Among the drawbacks of the method, carryover was identified as the main problem even though the Twisters were cleaned repeatedly.

  14. Determination of benzimidazole anthelmintics in animal-derived biological matrices.

    PubMed

    Neri, Bruno; Bidolli, Gentilina; Felli, Marialinda; Cozzani, Roberto

    2002-04-01

    This paper describes an easy multiresidue procedure for the determination of 8 benzimidazole anthelmintics (Albendazole, Albendazole sulphone, Albendazole sulphoxide, Ox-bendazole, Ossibendazole, p-OH-Fenbendazole, Fenbendazole, Flubendazole) in foodstuffs of animal origin for human consumption. According to the proposed procedure, 10 g of homogenised sample were extracted with acetonitrile in ultrasonic bath, the organic layer was evaporated to dryness and the residue dissolved in HCl 0.005 M. After an initial washing with hexane to remove fats, the aqueous layer was purified on SPE C2 column and the analytes were eluted with methanol, evaporated to dryness and reconstituted with phosphate buffer/acetonitrile (50/50). The solution obtained was analysed by HPLC with diode array detector (DAD); this detector provides useful information about the peaks present in routine samples, because it gains not only retention times of analytes, as well as their UV-spectra. Benzthiazuron was used as internal standard and the method was validated in the range 10-100 ppb, as requested by the imposed limits. The mean recoveries in spiked samples ranged between 70% and 95%, for 10 and 100 ppb respectively. The developed method resulted sensitive, simple and fast. It is particularly suitable for laboratories that execute screening analysis on a great number of samples, observing the EC regulations that establish the benzimidazole Maximum Residue Limits (MRLs) in food.

  15. 75 FR 5518 - Dithianon; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-03

    ... adequate methodology LC/MS/MS method (BASF 244882) is available for enforcing the proposed tolerance on grapes. Adequate multi-residue method testing data are available for dithianon and these data have been... docket index available at http://www.regulations.gov . Although listed in the index, some information is...

  16. A MULTI-RESIDUE METHOD FOR THE ANALYSIS OF INSECTICIDES COLLECTED ON COTTON SURFACE WIPES

    EPA Science Inventory

    A method was developed for the extraction, clean-up, and analysis of multiple pesticides from cotton wipe media used in human exposure studies to collect residues from residential hard surfaces. Measurements of pesticides are critical for estimating dermal and indirect ingestion ...

  17. Multi-residue pesticide analysis (gas chromatography-tandem mass spectrometry detection)-Improvement of the quick, easy, cheap, effective, rugged, and safe method for dried fruits and fat-rich cereals-Benefit and limit of a standardized apple purée calibration (screening).

    PubMed

    Rasche, Claudia; Fournes, Britta; Dirks, Uwe; Speer, Karl

    2015-07-17

    Some steps of the QuEChERS method for the analysis of pesticides with GC-MS/MS in cereals and dried fruits were improved or simplified. For the latter, a mixing vessel with stator-rotor-system proved to be advantageous. The extraction procedure of dried fruits is much easier and safer than the Ultra Turrax and results in excellent validation data at a concentration level of 0.01mg/kg (116 of 118 analytes with recoveries in the range of 70-120%, 117 of 118 analytes with RSD <20%). After qualifying problematic lipophilic pesticides in fat-rich cereals (fat content >7%), predominantly organochlorines showed recoveries of <70% in quantification when the standard QuEChERS method with water was used. A second extraction was carried out analogous to the QuEChERS method, however, without the addition of water. With this simple modification, the problematic lipophilic pesticides, which had been strongly affected by the fat content of the commodities, could be determined with recoveries above 70% even at a concentration level of 0.01mg/kg. Moreover, a GC-MS/MS screening method for 120 pesticides at a concentration level of 0.01mg/kg was established by employing analyte protectants (ethylglycerol, gulonolactone, and sorbitol). The use of only one standardized calibration, made of an apple purée extract in combination with analyte protectants, allowed for a qualitative and quantitative analysis of 120 pesticides in different matrix extracts (tomato, red pepper, sour cherries, dried apples, black currant powder, raisins, wheat flour, rolled oats, wheat germ). The analyte protectants leveled the differences in the matrix-induced protection effect of the analyzed extracts over a wide range. The majority of the pesticides were analyzed with good analytical results (recoveries in the range of 70-120% and RSD <20%). Copyright © 2015 Elsevier B.V. All rights reserved.

  18. A multiresidue approach for the simultaneous quantification of antibiotics in macroalgae by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Leston, Sara; Freitas, Andreia; Rosa, João; Barbosa, Jorge; Lemos, Marco F L; Pardal, Miguel Ângelo; Ramos, Fernando

    2016-10-15

    Together with fish, algae reared in aquaculture systems have gained importance in the last years, for many purposes. Besides their use as biofilters of effluents, macroalgae's rich nutritional profiles have increased their inclusion in human diets but also in animal feeds as sources of fatty acids, especially important for the fish industry. Nonetheless, algae are continuously exposed to environmental contaminants including antibiotics and possess the ability for bioaccumulation of such compounds. Therefore, the present paper describes the development and validation of an ultra-high performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous quantification of antibiotics in the green macroalgae Ulva lactuca. This multi-residue method enables the determination of 38 compounds distributed between seven classes and was fully validated according to EU Decision 2002/657/EC. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Liquid chromatographic-diode-array detection multiresidue determination of rice herbicides in drinking and paddy-field water.

    PubMed

    Roehrs, Rafael; Zanella, Renato; Pizzuti, Ionara; Adaime, Martha B; Pareja, Lucía; Niell, Silvina; Cesio, María V; Heinzen, Horacio

    2009-01-01

    A sensitive, rapid, and simple multiresidue method for the simultaneous determination of six postemergence herbicides currently used in rice cultivation--metsulfuron methyl, bensulfuron methyl, pyrazosulfuron ethyl, bentazone, bispyribac sodium, and cyhalofop butyl--in drinking and paddy-field water is presented. Water samples were extracted with solid-phase extraction cartridges. Final determination was made by LC with diode-array detection. The extraction efficiencies of C18 and HLB cartridges were compared. The average recovery obtained for these compounds for the lowest spiked level (0.1 microg/L) varied from 70 to 122% for C18 and 75-119% for HLB, with RSDs of 11 and 8.3%, respectively. The method had good linearity, and the lower detection limit for the pesticides studied varied from 0.03 to 0.04 microg/L. The proposed method was also tested in paddy-field water, with recovery studies giving good results with low RSDs at 1.0 microg/L.

  20. Multi-residue determination of pesticides in tropical fruits using liquid chromatography/tandem mass spectrometry.

    PubMed

    Botero-Coy, A M; Marín, J M; Ibáñez, M; Sancho, J V; Hernández, F

    2012-03-01

    Monitoring pesticide residues in tropical fruits is of great interest for many countries, e.g., from South America, that base an important part of their economy on the exportation of these products. In this work, a LC-MS/MS multi-residue method using a triple quadrupole analyzer has been developed for around 30 pesticides in seven Colombian tropical fruits of high commercial value for domestic and international markets (uchuva, tamarillo, granadilla, gulupa, maracuya, papaya, and pithaya). After sample extraction with acetonitrile, an aliquot of the extract was diluted with water and directly injected into the HPLC-MS/MS system (electrospray interface) without any cleanup step. The formation of sodium adducts-of poor fragmentation-was minimized using 0.1% formic acid in the mobile phase, which favored the formation of the protonated molecule. However, the addition of ammonium acetate made the formation of the ammonium adducts in some particular cases possible, avoiding the presence of the sodium adducts. The highest sensitivity was observed in positive electrospray ionization for the wide majority of pesticides, with a few exceptions for acidic compounds that gave better response in the negative mode (e.g., 2,4-D, fluazinan). Thus, simultaneous acquisition on the positive/negative mode was applied. Two MS/MS transitions were acquired for each compound to ensure a reliable quantification and identification of the compounds detected in samples, although for malathion a third transition was acquired due to the presence of interfering isobaric compounds in the sample extracts. A detailed study of matrix effects was made by a comparison of standards in solvent and in matrix. Both ionization suppression and ionization enhancement were observed depending on the analyte/matrix combination tested. Correction of matrix effects was made by the application of calibration in matrix. Three matrices were selected (uchuva, maracuya, gulupa) to perform matrix calibration in the analysis of all seven fruit varieties studied. The method was validated by recovery experiments in samples spiked at two levels (0.05 and 0.5 mg/kg). The data were satisfactory for the wide majority of analyte/matrix combinations, with most recoveries between 70% and 110% and the RSD below 15%. Several samples collected from the market were finally analyzed. Positive findings were confirmed by evaluating the experimental Q/q ratios and retention times, and comparing them with those of reference standards.

  1. Evaluation of a multiresidue method for measuring fourteen chemical groups of pesticides in water by use of LC-MS-MS.

    PubMed

    Carvalho, J J; Jerónimo, P C A; Gonçalves, C; Alpendurada, M F

    2008-11-01

    European Council Directive 98/83/EC on the quality of water intended for human consumption brought a new challenge for water-quality control routine laboratories, mainly on pesticides analysis. Under the guidelines of ISO/IEC 17025:2005, a multiresidue method was developed, validated, implemented in routine, and studied with real samples during a one-year period. The proposed method enables routine laboratories to handle a large number of samples, since 28 pesticides of 14 different chemical groups can be quantitated in a single procedure. The method comprises a solid-phase extraction step and subsequent analysis by liquid chromatography-mass spectrometry (LC-MS-MS). The accuracy was established on the basis of participation in interlaboratory proficiency tests, with encouraging results (majority |z-score| <2), and the precision was consistently analysed over one year. The limits of quantitation (below 0.050 microg L(-1)) are in agreement with the enforced threshold value for pesticides of 0.10 microg L(-1). Overall method performance is suitable for routine use according to accreditation rules, taking into account the data collected over one year.

  2. The utility of ultra-performance liquid chromatography/electrospray ionisation time-of-flight mass spectrometry for multi-residue determination of pesticides in strawberry.

    PubMed

    Taylor, Michael J; Keenan, George A; Reid, Kirsty B; Fernández, Diana Uría

    2008-09-01

    The utility of ultra-performance liquid chromatography/orthogonal-acceleration time-of flight mass spectrometry (UPLC/TOFMS) for the rapid qualitative and quantitative analysis of 100 pesticides targeted in strawberry was assessed by comparing results with those obtained using a validated in-house UPLC tandem mass spectrometry (MS/MS) multi-residue method. Crude extracts from retail strawberry samples received as part of the 2007 annual UK pesticide residues in food surveillance programme were screened for the presence of pesticide residues using UPLC/TOFMS. Accurate mass measurement of positive and negative ions allowed their extraction following 'full mass range data acquisition' with negligible interference from background or co-eluting species observed during UPLC gradient separation (in a cycle time of just 6.5 min per run). Extracted ion data was used to construct calibration curves and to detect and identify any incurred residues (i.e. pesticides incorporated in or on the test material following application during cultivation, harvest and storage). Calibration using matrix-matched standards was performed over a narrow concentration range of 0.005-0.04 mg kg(-1) with determination coefficients (r2) > or =0.99 for all analytes with the exception of malathion/fenarimol/fludioxanil (r2 = 0.98), quassia/pymetrazine (r2 = 0.97) and fenthion sulfone (r2 = 0.95). Residues found in selected samples ranged from 0.025-0.28 mg kg(-1) and were in excellent agreement with results obtained using UPLC/MS/MS. Mass measurement accuracies of < or =5 ppm were achieved consistently throughout the separation, mass range and concentration range of interest thus providing the opportunity to obtain discrete elemental compositions of target ions.

  3. Microwave assisted solvent extraction and coupled-column reversed-phase liquid chromatography with UV detection use of an analytical restricted-access-medium column for the efficient multi-residue analysis of acidic pesticides in soils.

    PubMed

    Hogendoom, E A; Huls, R; Dijkman, E; Hoogerbrugge, R

    2001-12-14

    A screening method has been developed for the determination of acidic pesticides in various types of soils. Methodology is based on the use of microwave assisted solvent extraction (MASE) for fast and efficient extraction of the analytes from the soils and coupled-column reversed-phase liquid chromatography (LC-LC) with UV detection at 228 nm for the instrumental analysis of uncleaned extracts. Four types of soils, including sand, clay and peat, with a range in organic matter content of 0.3-13% and ten acidic pesticides of different chemical families (bentazone, bromoxynil, metsulfuron-methyl, 2,4-D, MCPA, MCPP, 2,4-DP, 2,4,5-T, 2,4-DB and MCPB) were selected as matrices and analytes, respectively. The method developed included the selection of suitable MASE and LC-LC conditions. The latter consisted of the selection of a 5-microm GFF-II internal surface reversed-phase (ISRP, Pinkerton) analytical column (50 x 4.6 mm, I.D.) as the first column in the RAM-C18 configuration in combination with an optimised linear gradient elution including on-line cleanup of sample extracts and reconditioning of the columns. The method was validated with the analysis of freshly spiked samples and samples with aged residues (120 days). The four types of soils were spiked with the ten acidic pesticides at levels between 20 and 200 microg/kg. Weighted regression of the recovery data showed for most analyte-matrix combinations, including freshly spiked samples and aged residues, that the method provides overall recoveries between 60 and 90% with relative standard deviations of the intra-laboratory reproducibility's between 5 and 25%; LODs were obtained between 5 and 50 microg/kg. Evaluation of the data set with principal component analysis revealed that the parameters (i) increase of organic matter content of the soil samples and (ii) aged residues negatively effect the recovery of the analytes.

  4. Evaluation of a recent product to remove lipids and other matrix co-extractives in the analysis of pesticide residues and environmental contaminants in foods.

    PubMed

    Han, Lijun; Matarrita, Jessie; Sapozhnikova, Yelena; Lehotay, Steven J

    2016-06-03

    This study demonstrates the application of a novel lipid removal product to the residue analysis of 65 pesticides and 52 environmental contaminants in kale, pork, salmon, and avocado by fast, low pressure gas chromatography - tandem mass spectrometry (LPGC-MS/MS). Sample preparation involves QuEChERS extraction followed by use of EMR-Lipid ("enhanced matrix removal of lipids") and an additional salting out step for cleanup. The optimal amount of EMR-Lipid was determined to be 500mg for 2.5mL extracts for most of the analytes. The co-extractive removal efficiency by the EMR-Lipid cleanup step was 83-98% for fatty samples and 79% for kale, including 76% removal of chlorophyll. Matrix effects were typically less than ±20%, in part because analyte protectants were used in the LPGC-MS/MS analysis. The recoveries of polycyclic aromatic hydrocarbons and diverse pesticides were mostly 70-120%, whereas recoveries of nonpolar polybrominated diphenyl ethers and polychlorinated biphenyls were mostly lower than 70% through the cleanup procedure. With the use of internal standards, method validation results showed that 76-85 of the 117 analytes achieved satisfactory results (recoveries of 70-120% and RSD≤20%) in pork, avocado, and kale, while 53 analytes had satisfactory results in salmon. Detection limits were 5-10ng/g for all but a few analytes. EMR-Lipid is a new sample preparation tool that serves as another useful option for cleanup in multiresidue analysis, particularly of fatty foods. Published by Elsevier B.V.

  5. New Method for the Analysis of Flukicide and Other Anthelmintic Residues in Bovine Milk and Liver using LC-MS/MS

    USDA-ARS?s Scientific Manuscript database

    A liquid chromatographic-tandem mass spectrometric (LC-MS/MS) multi-residue method for the simultaneous quantification and identification of 38 residues of the most widely used anthelmintic veterinary drugs (including benzimidazoles, macrocyclic lactones, and flukicides) in milk and liver has been d...

  6. Ultra-Trace Analysis of Nine Macrolides, including Tulathromycin A (Draxxin), in Edible Animal Tissues with Mini-Column Liquid Chromatography Tandem Mass Spectrometry

    USDA-ARS?s Scientific Manuscript database

    Analysis of 9 macrolides is presented, including tulathromycin A (Draxxin), in beef, poultry and pork muscle with a simple multi-residue extraction and analysis method using high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The extraction method inv...

  7. MULTIRESIDUE DETERMINATION OF ACIDIC PESTICIDES ...

    EPA Pesticide Factsheets

    A multiresidue pesticide methodology has been studied and results for acidics are reported here with base/neutral to follow. This work studies a literature procedure as a possible general approach to many pesticides and potentially other analytes that are considered to be liquid chromatographic candidates rather than gas chromatographic ones. The analysis of thesewage effluent of a major southwestern US city serves as an example of the application of the methodology to a real sample. Recovery studies were also conducted to validate the proposed extraction step. A gradient elution program was followed for the high performance liquid chromatography leading to a general approach for acidics. Confirmation of identity was by EI GC/MS after conversion of the acids to the methyl ester (or other appropriate methylation) by means of trimethylsilyldiazomethane. The 3,4-dichlorophenoxyacetic acid was used as an internal standard to monitor the reaction and PCB #19 was used for the quantitation internal standard. Although others have reported similar analyses of acids, conversion to the methyl ester was by means of diazomethane itself rather than by the more convenient and safer trimethylsilyldiazomethane. Thus, the present paper supports the use of trimethylsilyldiazomethane with all of these acids (trimethylsilyldiazomethane has been used in environmental work with some phenoxyacetic acid herbicides) and further supports the usefulness of this reagent as a potential re

  8. Evaluation of bi-functionalized mesoporous silicas as reversed phase/cation-exchange mixed-mode sorbents for multi-residue solid phase extraction of veterinary drug residues in meat samples.

    PubMed

    Casado, Natalia; Pérez-Quintanilla, Damián; Morante-Zarcero, Sonia; Sierra, Isabel

    2017-04-01

    A SBA-15 type mesoporous silica was synthesized and bi-functionalized with octadecylsilane (C18) or octylsilane (C8), and sulfonic acid (SO 3 - ) groups in order to obtain materials with reversed-phase/strong cation-exchange mixed-mode retention mechanism. The resulting hybrid materials (SBA-15-C18-SO 3 - and SBA-15-C8-SO 3 - ) were comprehensively characterized. They showed high surface area, high pore volume and controlled porous size. Elemental analysis of the materials revealed differences in the amount of C18 and C8. SBA-15-C18-SO 3 - contained 0.19mmol/g of C18, while SBA-15-C8-SO 3 - presented 0.54mmol/g of C8. The SO 3 - groups anchored to the silica surface of the pore walls were 0.20 and 0.09mmol/g, respectively. The bi-functionalized materials were evaluated as SPE sorbents for the multi-residue extraction of 26 veterinary drug residues in meat samples using ultra-high-performance liquid chromatography coupled to mass spectrometry detector (UHPLC-MS/MS). Different sorbent amounts (100 and 200mg) and organic solvents were tested to optimize the extraction procedure. Both silicas showed big extraction potential and were successful in the extraction of the target analytes. The mixed-mode retention mechanism was confirmed by comparing both silicas with SBA-15 mesoporous silica mono-functionalized with C18 and C8. Best results were achieved with 200mg of SBA-15-C18-SO 3 - obtaining recoveries higher than 70% for the majority of analytes. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Trace analysis of three fungicides in animal origin foods with a modified QuEChERS method and liquid chromatography-tandem mass spectrometry.

    PubMed

    Mu, Zhaobin; Feng, Xiaoxiao; Zhang, Yun; Zhang, Hongyan

    2016-02-01

    A multi-residue method based on modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) sample preparation, followed by liquid chromatography tandem mass spectrometry (LC-MS/MS), was developed and validated for the determination of three selected fungicides (propiconazole, pyraclostrobin, and isopyrazam) in seven animal origin foods. The overall recoveries at the three spiking levels of 0.005, 0.05, and 0.5 mg kg(-1) spanned between 72.3 and 101.4% with relative standard deviation (RSD) values between 0.7 and 14.9%. The method shows good linearity in the concentrations between 0.001 and 1 mg L(-1) with the coefficient of determination (R (2)) value >0.99 for each target analyte. The limit of detections (LODs) for target analytes were between 0.04 and 1.26 μg kg(-1), and the limit of quantifications (LOQs) were between 0.13 and 4.20 μg kg(-1). The matrix effect for each individual compound was evaluated through the study of ratios of the areas obtained in solvent and matrix standards. The optimized method provided a negligible matrix effect for propiconazole within 20%, whereas for pyraclostrobin and isopyrazam, the matrix effect was relatively significant with a maximum value of 49.8%. The developed method has been successfully applied to the analysis of 210 animal origin samples obtained from 16 provinces of China. The results suggested that the developed method was satisfactory for trace analysis of three fungicides in animal origin foods.

  10. Simultaneous analysis of 70 pesticides using HPlc/MS/MS: a comparison of the multiresidue method of Klein and Alder and the QuEChERS method.

    PubMed

    Riedel, Melanie; Speer, Karl; Stuke, Sven; Schmeer, Karl

    2010-01-01

    Since 2003, two new multipesticide residue methods for screening crops for a large number of pesticides, developed by Klein and Alder and Anastassiades et al. (Quick, Easy, Cheap, Effective, Rugged, and Safe; QuEChERS), have been published. Our intention was to compare these two important methods on the basis of their extraction efficiency, reproducibility, ruggedness, ease of use, and speed. In total, 70 pesticides belonging to numerous different substance classes were analyzed at two concentration levels by applying both methods, using five different representative matrixes. In the case of the QuEChERS method, the results of the three sample preparation steps (crude extract, extract after SPE, and extract after SPE and acidification) were compared with each other and with the results obtained with the Klein and Alder method. The extraction efficiencies of the QuEChERS method were far higher, and the sample preparation was much quicker when the last two steps were omitted. In most cases, the extraction efficiencies after the first step were approximately 100%. With extraction efficiencies of mostly less than 70%, the Klein and Alder method did not compare favorably. Some analytes caused problems during evaluation, mostly due to matrix influences.

  11. Simultaneous and confirmative detection of multi-residues of β₂-agonists and β-blockers in urine using LC-MS/MS/MS coupled with β-receptor molecular imprinted polymer SPE clean-up.

    PubMed

    Fan, S; Zou, J H; Miao, H; Zhao, Y F; Chen, H J; Zhao, R; Wu, Y N

    2013-01-01

    A liquid chromatography-linear ion-trap spectrometry (LC-MS³) method using β-receptor molecular-imprinted polymer (MIP) solid-phase extraction (SPE) as clean-up was developed to determine simultaneously and confirmatively residues of 25 β₂-agonists and 21 β-blockers in urine samples. Urine samples were subjected to enzymatic hydrolysis by β-glucoronidase/arylsulphatase, and then extracted with perchloric acid. Sample clean-up was performed using β-receptor MIP SPE. A Supelco Ascentis® express Rp-Amide column was used to separate the analytes, and MS³ detection used an electrospray ionisation source in positive-ion mode. Recovery studies were carried out using blank urine samples fortified with the 46 analytes at the levels of 0.5, 1.0 and 2.0 μg l⁻¹. Recoveries were obtained ranging from 60.1% to 109.9% with relative standard deviations (RSDs, n = 7) from 0.5% to 19.4%. The limits of detection (LODs) and limits of quantitation (LOQs) of the 46 analytes in urine were 0.02-0.18 and 0.05-0.60 μg l⁻¹, respectively. As a result of the selective clean-up by MIP SPE and MS³ detection of the target drugs, the sensitivity and accuracy of the present method was high enough for monitoring β₂-agonist and β-blocker residues in urine samples. Satisfactory results were obtained in the process of the determination of positive urine samples.

  12. Ultra-high-pressure liquid chromatography-tandem mass spectrometry for the analysis of six resorcylic acid lactones in bovine milk.

    PubMed

    Xia, Xi; Li, Xiaowei; Ding, Shuangyang; Zhang, Suxia; Jiang, Haiyang; Li, Jiancheng; Shen, Jianzhong

    2009-03-20

    This work reports a rapid, reliable and sensitive multi-residue method for the simultaneous determination of six resorcylic acid lactones in bovine milk by ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The resorcylic acid lactones were extracted, purified, and concentrated from milk samples in one step using a solid-phase extraction (SPE) cartridge that contained a polymeric mixed-mode anion-exchange sorbent. The analysis was performed on a Waters Acquity BEH C(18) column utilizing a gradient elution profile. Each LC run was completed in 3.5 min. The analytes were detected by multiple reaction monitoring (MRM) using electrospray ionization (ESI) negative mode. Mean recoveries from fortified samples ranged from 92.6% to 112.5%, with relative standard deviations lower than 11.4%. Using 5 mL bovine milk, the limits of detection and quantification for resorcylic acid lactones were in the ranges of 0.01-0.05 and 0.05-0.2 microg/L, respectively. The application of this newly developed method was demonstrated by analyzing bovine milk samples from markets.

  13. QuEChERS GC-MS validation and monitoring of pesticide residues in different foods in the tomato classification group.

    PubMed

    Ramírez Restrepo, Andrés; Gallo Ortiz, Andrés Fernando; Hoyos Ossa, Duvan Esteban; Peñuela Mesa, Gustavo Antonio

    2014-09-01

    The objective of this study was to validate (SANCO/12495/2011 and NTC-ISO/IEC 17025) multi-residue multi-class methods using QuEChERS sample preparation and GC-MS for the analysis of regulated pesticides in tomatoes (Solanum lycopersicum), tamarillos (Solanum betaceum) and goldenberries (Physalis peruviana). These Latin American products are representative and widely produced in Antioquia (Colombia). Sample preparation followed the UNE-EN 15662 method (150 mg MgSO4, 25mg primary secondary amines and 25mg of octadecylsiloxane for cleanup; graphitized carbon black was added for tomatoes). Extracts were injected using a programmed temperature-vaporizing injector. The residues were validated over a range from 0.02 mg/kg to 0.20 mg/kg, with 24 analytes validated in tomatoes, 33 in tamarillos and 28 in goldenberries. An initial risk assessment was enabled by monitoring 24 samples in the municipalities of El Peñol, Marinilla and San Vicente Ferrer. Risks were found for tomatoes, but no significant risks were found for tamarillos or goldenberries. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Multiresidue analysis of 24 Water Framework Directive priority substances by on-line solid phase extraction-liquid chromatography tandem mass spectrometry in environmental waters.

    PubMed

    Rubirola, Adrià; Boleda, Mª Rosa; Galceran, Mª Teresa

    2017-04-14

    This paper reports the development of a fully multiresidue and automated on-line solid phase extraction (SPE) - liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of 24 priority substances (PS) belonging to different classes (pesticides, hormones or pharmaceuticals) included in the Directive 2013/39/UE and the recent Watch List (Decision 2015/495) in water samples (drinking water, surface water, and effluent wastewaters). LC-MS/MS conditions and on-line SPE parameters such as sorbent type, sample and wash volumes were optimized. The developed method is highly sensitive (limits of detection between 0.1 and 1.4ngL -1 ) and precise (relative standard deviations lower than 8%). As part of the method validation studies, linearity, accuracy and matrix effects were assessed. The main advantage of this method over traditional off-line procedures is the minimization of tedious sample preparation increasing productivity and sample throughput. The optimized method was applied to the analysis of water samples and the results revealed the presence of 16 PS in river water and effluent water of wastewater treatment plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Multiresidue method for pesticide residue analysis in food of animal and plant origin based on GC or LC and MS or MS/MS.

    PubMed

    Muñoz, Eva; Muñoz, Gloria; Pineda, Laura; Serrahima, Eulalia; Centrich, Francesc

    2012-01-01

    A multiresidue method based on GC or LC and MS or MS/MS for the determination of 204 pesticides in diverse food matrixes of animal and plant origin is described. The method can include different stages of cleanup according to the chemical characteristics of each sample. Samples were extracted using accelerated solvent extraction. Those with a high fat content or that contained chlorophyll required further purification by gel permeation chromatography and/or SPE (ENVI-Carb). The methodology developed here was fully validated; the LOQs for the 204 pesticides are presented. The LOQ values lie between 0.01 to 0.02 mg/kg. However, in some cases, mainly in baby food, they were as low as 0.003 mg/kg, thereby meeting European Union requirements on maximum residue levels for pesticides, as outlined in European regulation 396/2005 and the Commission Directive 2003/13/EC. The procedure has been accredited for a wide scope of pesticides and matrixes by the Spanish Accreditation Body (ENAC) following ISO/IEC 17025:2005, as outlined in ENAC technical note NT-19.

  16. Simultaneous determination of multi-residue and multi-class antibiotics in aquaculture shrimps by UPLC-MS/MS.

    PubMed

    Saxena, Sushil Kumar; Rangasamy, Rajesh; Krishnan, Anoop A; Singh, Dhirendra P; Uke, Sumedh P; Malekadi, Praveen Kumar; Sengar, Anoop S; Mohamed, D Peer; Gupta, Ananda

    2018-09-15

    An accurate, reliable and fast multi-residue, multi-class method using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed and validated for simultaneous determination and quantification of 24 pharmacologically active substances of three different classes (Quinolones including fluoroquinolones, sulphonamides and tetracyclines) in aquaculture shrimps. Sample preparation involves extraction with acetonitrile containing 0.1% formic acid and followed by clean up with n-hexane and 0.1% methanol in water by UPLC-MS/MS within 8 min. The method was validated according to European Commission Decision 2002/657. Acceptable values were obtained for linearity (5-200 μg kg -1 ), specificity, Limit of Quantification (5-10 μg kg -1 ), recovery (between 83 and 100%), repeatability (RSD < 9%), within lab reproducibility (RSD < 15%), reproducibility (RSD ≤ 22%), decision limit (105-116 μg kg -1 ) and detection capability (110-132 μg kg -1 ). The validated method was applied to aquaculture shrimp samples from India. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Determination of pharmaceutical residues in drinking water in Poland using a new SPE-GC-MS(SIM) method based on Speedisk extraction disks and DIMETRIS derivatization.

    PubMed

    Caban, Magda; Lis, Ewa; Kumirska, Jolanta; Stepnowski, Piotr

    2015-12-15

    The presence of pharmaceuticals in drinking water, even at very low concentrations, has raised concerns among stakeholders such as drinking-water regulators, governments, water suppliers and the public, with regard to the potential risks to humans. Despite this, the occurrence and the fate of pharmaceuticals in drinking waters of many countries (e.g. in Poland) remains unknown. There is a lack of sufficiently sensitive and reliable analytical methods for such analyses and a need for more in-depth hydrogeological analysis of the possible sources of drug residues in drinking water. In this paper, a multi-residual method for the simultaneous determination of seventeen human pharmaceuticals in drinking waters has been developed. Large-volume extractions using Speedisk extraction disks, and derivatization prior to GC-MS-SIM analysis using a new silylating agent DIMETRIS were applied. The method detection limits (MDLs) ranged from 0.9 to 5.7ng/L and the absolute recoveries of the target compounds were above 80% for most analytes. The developed method was successfully applied in the analysis of the target compounds in drinking water collected in Gdansk (Poland), and of the 17 pharmaceuticals, 6 compounds were detected at least once. During the investigation, the geomorphology of the site region was taken into account, possible sources of pharmaceuticals in the analysed drinking water samples were investigated, and the presence of the drugs in ground and surface waters, raw and treated drinking waters was determined. Concentrations were also compared with those observed in other countries. As a result, this study has not only developed a new analytical method for determining pharmaceuticals in drinking waters as well as rendering missing information for Poland (a country with one of the highest consumptions of pharmaceuticals in Europe), but it also presents a modelled in-depth hydrogeological analysis of the real sources of drugs in drinking waters. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Quantitative determination of several synthetic corticosteroids by gas chromatography-mass spectrometry after purification by immunoaffinity chromatography.

    PubMed

    Delahaut, P; Jacquemin, P; Colemonts, Y; Dubois, M; De Graeve, J; Deluyker, H

    1997-08-29

    A study was conducted to test a multiresidue analytical procedure for detecting and quantifying several corticosteroids on which the European Union imposes maximum residue limits (MRLs). Primary extracts from different matrices (liver, milk, urine, faeces) were first purified on C18 cartridges. A new immunoaffinity clean-up step was included. The immunoaffinity gel was used to purify several corticosteroids simultaneously with enrichment of the corresponding fractions. The extracts were treated with an aqueous solution of pyridinium chlorochromate to fully oxidise all corticosteroids and to facilitate their extraction with dichloromethane. After evaporation, the final extract was reconstituted with toluene before injection into the GC-MS apparatus. The analysis was performed in the CI-negative ionisation mode using ammonia as the reactant gas. The estimated detection and quantification limits were, respectively, 0.25 and 0.5 ppb or lower. Overall, the method is reproducible to within 20%. Recovery is between 50 and 80% according to the corticosteroid.

  19. Effect of paste processing on residue levels of imidacloprid, pyraclostrobin, azoxystrobin and fipronil in winter jujube.

    PubMed

    Peng, Wei; Zhao, Liuwei; Liu, Fengmao; Xue, Jiaying; Li, Huichen; Shi, Kaiwei

    2014-01-01

    The changes of imidacloprid, pyraclostrobin, azoxystrobin and fipronil residues were studied to investigate the carryover of pesticide residues in winter jujube during paste processing. A multi-residue analytical method for winter jujube was developed based on the QuEChERS approach. The recoveries for the pesticides were between 87.5% and 116.2%. LODs ranged from 0.002 to 0.1 mg kg(-1). The processing factor (Pf) is defined as the ratio of pesticide residue concentration in the paste to that in winter jujube. Pf was higher than 1 for the removal of extra water, and other steps were generally less than 1, indicating that the whole process resulted in lower pesticide residue levels in paste. Peeling would be the critical step for pesticide removal. Processing factors varied among different pesticides studied. The results are useful to address optimisation of the processing techniques in a manner that leads to considerable pesticide residue reduction.

  20. Identification of multi-insecticide residues using GC-NPD and the degradation kinetics of chlorpyrifos in sweet corn and soils.

    PubMed

    Wang, Peidan; Rashid, Muhammad; Liu, Jie; Hu, Meiying; Zhong, Guohua

    2016-12-01

    Because more than one insecticide is applied to crops to protect plants from pests, an analytical multi-residue determination method was developed using gas chromatography with a nitrogen phosphorus detector (GC-NPD). The retention time for 12 insecticides was 3.7-27.7min. Under the selected conditions, the limits of detection (LOD) and quantification (LOQ) were below the maximum residue limits (MRLs) and in the range of 0.00315-0.05μgmL(-1) and 0.01-0.165μgmL(-1), respectively. Using GC-NPD, we investigated the dissipation dynamics and final residual levels of chlorpyrifos in sweet corn and soil and determined that the half-lives was 4-7days, that is, that chlorpyrifos is safe to use on sweet corn with a pre-harvest interval of 16-22days before harvest. These results provide new insights into chlorpyrifos degradation in plants and its environmental behavior. Copyright © 2016. Published by Elsevier Ltd.

  1. Evaluation of an analytical methodology using QuEChERS and GC-SQ/MS for the investigation of the level of pesticide residues in Brazilian melons.

    PubMed

    da Silva Sousa, Jonas; de Castro, Rubens Carius; de Albuquerque Andrade, Gilliane; Lima, Cleidiane Gomes; Lima, Lucélia Kátia; Milhome, Maria Aparecida Liberato; do Nascimento, Ronaldo Ferreira

    2013-12-01

    A multiresidue method based on the sample preparation by modified QuEChERS and detection by gas chromatography coupled to single quadruple mass spectrometers (GC-SQ/MS) was used for the analysis of 35 multiclass pesticides in melons (Cucumis melo inodorus) produced in Ceara-Brazil. The rates of recovery for pesticides studied were satisfactory (except for the etridiazole), ranging from 85% to 117% with a relative standard deviation (RSD) of less than 15%, at concentrations between 0.05 and 0.20 mg kg(-1). The limit of quantification (LOQ) for most compounds was below the MRLs established in Brazil. The combined relative uncertainty (Uc) and expanded uncertainty (Ue) was determined using repeatability, recovery and calibration curves data for each pesticide. Analysis of commercial melons samples revealed the presence of pesticides bifenthrin and imazalil at levels below the MRLs established by ANVISA, EU and USEPA. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Validation of QuEChERS analytical technique for organochlorines and synthetic pyrethroids in fruits and vegetables using GC-ECD.

    PubMed

    Dubey, J K; Patyal, S K; Sharma, Ajay

    2018-03-19

    In the present day scenario of increasing awareness and concern about the pesticides, it is very important to ensure the quality of data being generated in pesticide residue analysis. To impart confidence in the products, terms like quality assurance and quality control are used as an integral part of quality management. In order to ensure better quality of results in pesticide residue analysis, validation of analytical methods to be used is extremely important. Keeping in view the importance of validation of method, the validation of QuEChERS (quick, easy, cheap, effective, rugged, and safe) a multiresidue method for extraction of 13 organochlorines and seven synthetic pyrethroids in fruits and vegetables followed by GC ECD for quantification was done so as to use this method for analysis of samples received in the laboratory. The method has been validated as per the Guidelines issued by SANCO (French words Sante for Health and Consommateurs for Consumers) in accordance with their document SANCO/XXXX/2013. Various parameters analyzed, viz., linearity, specificity, repeatability, reproducibility, and ruggedness were found to have acceptable values with a per cent RSD of less than 10%. Limit of quantification (LOQ) for the organochlorines was established to be 0.01 and 0.05 mg kg -1 for the synthetic pyrethroids. The uncertainty of the measurement (MU) for all these compounds ranged between 1 and 10%. The matrix-match calibration was used to compensate the matrix effect on the quantification of the compounds. The overall recovery of the method ranged between 80 and 120%. These results demonstrate the applicability and acceptability of this method in routine estimation of pesticide residues of these 20 pesticides in the fruits and vegetables by the laboratory.

  3. Development of fast and robust multiresidual LC-MS/MS method for determination of pharmaceuticals in soils.

    PubMed

    Golovko, Oksana; Koba, Olga; Kodesova, Radka; Fedorova, Ganna; Kumar, Vimal; Grabic, Roman

    2016-07-01

    The aim of this study was to develop a simple extraction procedure and a multiresidual liquid chromatography-tandem mass spectrometry method for determination of a wide range of pharmaceuticals from various soil types. An extraction procedure for 91 pharmaceuticals from 13 soil types, followed by liquid chromatography-tandem mass spectrometry analysis, was optimized. The extraction efficiencies of three solvent mixtures for ultrasonic extraction were evaluated for 91 pharmaceuticals. The best results were obtained using acetonitrile/water (1/1 v/v with 0.1 % formic acid) followed by acetonitrile/2-propanol/water (3/3/4 v/v/v with 0.1 % formic acid) for extracting 63 pharmaceuticals. The method was validated at three fortification levels (10, 100, and 1000 ng/g) in all types of representative soils; recovery of 44 pharmaceuticals ranged between 55 and 135 % across all tested soils. The method was applied to analyze actual environmental samples of sediments, soils, and sludge, and 24 pharmaceuticals were found above limit of quantification with concentrations ranging between 0.83 ng/g (fexofenadine) and 223 ng/g (citalopram).

  4. Pesticide residues in cashew apple, guava, kaki and peach: GC-μECD, GC-FPD and LC-MS/MS multiresidue method validation, analysis and cumulative acute risk assessment.

    PubMed

    Jardim, Andréia Nunes Oliveira; Mello, Denise Carvalho; Goes, Fernanda Caroline Silva; Frota Junior, Elcio Ferreira; Caldas, Eloisa Dutra

    2014-12-01

    A multiresidue method for the determination of 46 pesticides in fruits was validated. Samples were extracted with acidified ethyl acetate, MgSO4 and CH3COONa and cleaned up by dispersive SPE with PSA. The compounds were analysed by GC-FPD, GC-μECD or LC-MS/MS, with LOQs from 1 to 8 μg/kg. The method was used to analyse 238 kaki, cashew apple, guava, and peach fruit and pulp samples, which were also analysed for dithiocarbamates (DTCs) using a spectrophotometric method. Over 70% of the samples were positive, with DTC present in 46.5%, λ-cyhalothrin in 37.1%, and omethoate in 21.8% of the positive samples. GC-MS/MS confirmed the identities of the compounds detected by GC. None of the pesticides found in kaki, cashew apple and guava was authorised for these crops in Brazil. The risk assessment has shown that the cumulative acute intake of organophosphorus or pyrethroid compounds from the consumption of these fruits is unlikely to pose a health risk to consumers. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Simultaneous determination of mequindox, quinocetone, and their major metabolites in chicken and pork by UPLC-MS/MS

    USDA-ARS?s Scientific Manuscript database

    This research presents a sensitive and confirmatory multi-residue method for mequindox (MEQ), quinocetone (QCT), and their 11 metabolites in chicken and pork samples. After extracted with acetonitrile-ethyl acetate, acidulated, and extracted again with ethyl acetate sequentially, each sample was pu...

  6. Multiresidue analysis of pesticides in traditional Chinese medicines using gas chromatography - negative chemical ionization tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    In this study, a residue analysis method for the simultaneous determination of 107 pesticides in the traditional Chinese medicines (TCMs), Angelica sinensis, Angelica dahurica, Leonurus heterophyllus Sweet, Pogostemon cablin, and Lonicera japonica Thunb, was developed using gas chromatography couple...

  7. Post-acquisition data processing for the screening of transformation products of different organic contaminants. Two-year monitoring of river water using LC-ESI-QTOF-MS and GCxGC-EI-TOF-MS.

    PubMed

    López, S Herrera; Ulaszewska, M M; Hernando, M D; Martínez Bueno, M J; Gómez, M J; Fernández-Alba, A R

    2014-11-01

    This study describes a comprehensive strategy for detecting and elucidating the chemical structures of expected and unexpected transformation products (TPs) from chemicals found in river water and effluent wastewater samples, using liquid chromatography coupled to electrospray ionization quadrupole-time-of-flight mass spectrometer (LC-ESI-QTOF-MS), with post-acquisition data processing and an automated search using an in-house database. The efficacy of the mass defect filtering (MDF) approach to screen metabolites from common biotransformation pathways was tested, and it was shown to be sufficiently sensitive and applicable for detecting metabolites in environmental samples. Four omeprazole metabolites and two venlafaxine metabolites were identified in river water samples. This paper reports the analytical results obtained during 2 years of monitoring, carried out at eight sampling points along the Henares River (Spain). Multiresidue monitoring, for targeted analysis, includes a group of 122 chemicals, amongst which are pharmaceuticals, personal care products, pesticides and PAHs. For this purpose, two analytical methods were used based on direct injection with a LC-ESI-QTOF-MS system and stir bar sorptive extraction (SBSE) with bi-dimensional gas chromatography coupled with a time-of-flight spectrometer (GCxGC-EI-TOF-MS).

  8. Assessment of priority pesticides, degradation products, and pesticide adjuvants in groundwaters and top soils from agricultural areas of the Ebro river basin.

    PubMed

    Hildebrandt, Alain; Lacorte, Sílvia; Barceló, Damià

    2007-02-01

    Gas chromatography-mass spectrometry (GC/MS) was employed for the determination of 30 widely used pesticides including various transformation products and alkylphenols in water and agricultural soils with the aim of assessing the impact of these compounds in agricultural soils and the underlying aquifer. The extraction, clean-up, and analytical procedures were optimized for both water and soil samples to provide a highly robust method capable of determining target analytes at the ppb-ppt level with high precision. For water samples, different solid-phase extraction cartridges and conditions were optimized; similarly, pressurized liquid extraction conditions were tested to provide interference-free extracts and high sensitivity. Instrumental LODs of 3-4 pg were obtained. The multi-residue extraction procedures were applied to the analysis of groundwaters and agricultural soils from the Ebro river basin (NE Spain). Most ubiquitous herbicides detected were triazines but some acetanilides and organophosphorus pesticides were also found; the pesticide additive tributylphosphate was found in all water samples. Levels varied between 0.57 and 5.37 microg/L in groundwater, whereas nonylphenol was the sole compound detected in soil. Alkylphenols are used as adjuvants in pesticide formulations and are present in sludges employed as soil fertilizers. Occurrence was found to be similar to other environmental studies.

  9. Multi-residue analysis of legacy POPs and emerging organic contaminants in Singapore's coastal waters using gas chromatography-triple quadrupole tandem mass spectrometry.

    PubMed

    Zhang, Hui; Bayen, Stéphane; Kelly, Barry C

    2015-08-01

    A gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS) based method was developed for determination of 86 hydrophobic organic compounds in seawater. Solid-phase extraction (SPE) was employed for sequestration of target analytes in the dissolved phase. Ultrasound assisted extraction (UAE) and florisil chromatography were utilized for determination of concentrations in suspended sediments (particulate phase). The target compounds included multi-class hydrophobic contaminants with a wide range of physical-chemical properties. This list includes several polycyclic and nitro-aromatic musks, brominated and chlorinated flame retardants, methyl triclosan, chlorobenzenes, organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs). Spiked MilliQ water and seawater samples were used to evaluate the method performance. Analyte recoveries were generally good, with the exception of some of the more volatile target analytes (chlorobenzenes and bromobenzenes). The method is very sensitive, with method detection limits typically in the low parts per quadrillion (ppq) range. Analysis of 51 field-collected seawater samples (dissolved and particulate-bound phases) from four distinct coastal sites around Singapore showed trace detection of several polychlorinated biphenyl congeners and other legacy POPs, as well as several current-use emerging organic contaminants (EOCs). Polycyclic and nitro-aromatic musks, bromobenzenes, dechlorane plus isomers (syn-DP, anti-DP) and methyl triclosan were frequently detected at appreciable levels (2-20,000pgL(-1)). The observed concentrations of the monitored contaminants in Singapore's marine environment were generally comparable to previously reported levels in other coastal marine systems. To our knowledge, these are the first measurements of these emerging contaminants of concern in Singapore or Southeast Asia. The developed method may prove beneficial for future environmental monitoring of hydrophobic organic contaminants in marine environments. Further, the study provides novel information regarding several potentially hazardous contaminants of concern in Singapore's marine environment, which will aid future risk assessment initiatives. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Development of a multi-residue analytical methodology based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for screening and trace level determination of pharmaceuticals in surface and wastewaters.

    PubMed

    Gros, Meritxell; Petrović, Mira; Barceló, Damiá

    2006-11-15

    This paper describes development, optimization and validation of a method for the simultaneous determination of 29 multi-class pharmaceuticals using off line solid phase extraction (SPE) followed by liquid chromatography-triple quadrupole mass spectrometry (LC-MS-MS). Target compounds include analgesics and non-steroidal anti-inflammatories (NSAIDs), lipid regulators, psychiatric drugs, anti-histaminics, anti-ulcer agent, antibiotics and beta-blockers. Recoveries obtained were generally higher than 60% for both surface and wastewaters, with exception of several compounds that yielded lower, but still acceptable recoveries: ranitidine (50%), sotalol (50%), famotidine (50%) and mevastatin (34%). The overall variability of the method was below 15%, for all compounds and all tested matrices. Method detection limits (MDL) varied between 1 and 30ng/L and from 3 to 160ng/L for surface and wastewaters, respectively. The precision of the method, calculated as relative standard deviation (R.S.D.), ranged from 0.2 to 6% and from 1 to 11% for inter and intra-day analysis, respectively. A detailed study of matrix effects was performed in order to evaluate the suitability of different calibration approaches (matrix-matched external calibration, internal calibration, extract dilution) to reduce analyte suppression or enhancement during instrumental analysis. The main advantages and drawbacks of each approach are demonstrated, justifying the selection of internal standard calibration as the most suitable approach for our study. The developed analytical method was successfully applied to the analysis of pharmaceutical residues in WWTP influents and effluents, as well as in river water. For both, river and wastewaters, the most ubiquitous compounds belonged to the group of anti-inflammatories and analgesics, antibiotics, the lipid regulators being acetaminophen, trimethoprim, ibuprofen, ketoprofen, atenolol, propranolol, mevastatin, carbamazepine and ranitidine the most frequently detected compounds.

  11. UNE-EN ISO/IEC 17025:2005-accredited method for the determination of pesticide residues in fruit and vegetable samples by LC-MS/MS.

    PubMed

    Camino-Sánchez, F J; Zafra-Gómez, A; Oliver-Rodríguez, B; Ballesteros, O; Navalón, A; Crovetto, G; Vílchez, J L

    2010-11-01

    A rapid, simple and sensitive multi-residue method was developed and validated for the simultaneous quantification and confirmation of 69 pesticides in fruit and vegetables using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted following the quick, easy, cheap, effective, rugged and safe method known as QuEChERS. Mass spectrometric conditions were individually optimised for each analyte in order to achieve maximum sensitivity in multiple reaction monitoring (MRM) mode. Using the developed chromatographic conditions, 69 pesticides can be separated in less than 17 min. Two selected reaction monitoring (SRM) assays were used for each pesticide to obtain simultaneous quantification and identification in one run. With this method in SRM mode, more than 150 pesticides can be analysed and quantified, but their confirmation is not possible in all cases according to the European regulations on pesticide residues. Nine common representative matrices (zucchini, melon, cucumber, watermelon, tomato, garlic, eggplant, lettuce and pepper) were selected to investigate the effect of different matrices on recovery and precision. Mean recoveries ranged from 70% to 120%, with relative standard deviations (RSDs) lower than 20% for all the pesticides. The proposed method was applied to the analysis of more than 2000 vegetable samples from the extensive greenhouse cultivation in the province of Almeria, Spain, during one year. The methodology combines the advantages of both QuEChERS and LC-MS/MS producing a very rapid, sensitive, accurate and reliable procedure that can be applied in routine analytical laboratories. The method was validated and accredited according to UNE-EN-ISO/IEC 17025:2005 international standard (accreditation number 278/LE1027).

  12. A multiresidue method for the analysis of 90 pesticides, 16 PAHs, and 22 PCBs in honey using QuEChERS-SPME.

    PubMed

    Al-Alam, Josephine; Fajloun, Ziad; Chbani, Asma; Millet, Maurice

    2017-08-01

    An optimized analytical method was developed for the simultaneous analysis of 90 pesticides, 16 polycyclic aromatic hydrocarbons, and 22 polychlorinated biphenyls. The method was based on quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction using acetonitrile followed by a dispersive solid-phase extraction cleanup using primary-secondary amine and octadecyl (C 18 ). The extract obtained was concentrated by evaporation and then reconstituted with acetonitrile to prepare it for chromatographic analysis by liquid chromatography-triple-quadrupole tandem mass spectrometry and gas chromatography-ion-trap tandem mass spectrometry, which was preceded by a preconcentration step using solid-phase microextraction with appropriate fibers. The combination of the two extraction steps ensured efficient extract cleanup. The use of the two analytical instruments allowed the analysis of a large number of pollutants with a high reliability rate. The method developed was validated for linearity, which was studied with use of matrix-matched calibration curves in the concentration range between 10 and 3000 ng g -1 . The correlation coefficient (R 2 ) obtained was higher than 0.98 for most of the target compounds, with a relative standard deviation lower than 20% for repeatability and reproducibility. The limits of detection and quantification were lower than 20 and 60 ng g -1 respectively for the compounds analyzed, and the recoveries were between 60% and 103% for most compounds. Finally, the method was tested for its efficiency on real samples by the analysis of three honey samples in which seven pesticides and nine polycyclic aromatic hydrocarbons were determined. Graphical Abstract ᅟ.

  13. Polydopamine-coated magnetic nanoparticles for isolation and enrichment of estrogenic compounds from surface water samples followed by liquid chromatography-tandem mass spectrometry determination.

    PubMed

    Capriotti, Anna Laura; Cavaliere, Chiara; La Barbera, Giorgia; Piovesana, Susy; Samperi, Roberto; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2016-06-01

    Estrogens, phytoestrogens, and mycoestrogens may enter into the surface waters from different sources, such as effluents of municipal wastewater treatment plants, industrial plants, and animal farms and runoff from agricultural areas. In this work, a multiresidue analytical method for the determination of 17 natural estrogenic compounds, including four steroid estrogens, six mycoestrogens, and seven phytoestrogens, in river water samples has been developed. (Fe3O4)-based magnetic nanoparticles coated by polydopamine (Fe3O4@pDA) were used for dispersive solid-phase extraction, and the final extract was analyzed by ultra-high performance liquid chromatography coupled with tandem mass spectrometry. The Fe3O4 magnetic nanoparticles were prepared by a co-precipitation procedure, coated by pDA, and characterized by scanning electron microscopy, infrared spectroscopy, and elemental analysis. The sample preparation method was optimized in terms of extraction recovery, matrix effect, selectivity, trueness, precision, method limits of detection, and method limits of quantification (MLOQs). For all the 17 analytes, recoveries were >70 % and matrix effects were below 30 % when 25 mL of river water sample was treated with 90 mg of Fe3O4@pDA nanoparticles. Selectivity was tested by spiking river water samples with 50 other compounds (mycotoxins, antibacterials, conjugated hormones, UV filters, alkylphenols, etc.), and only aflatoxins and some benzophenones showed recoveries >60 %. This method proved to be simple and robust and allowed the determination of natural estrogenic compounds belonging to different classes in surface waters with MLOQs ranging between 0.003 and 0.1 μg L(-1). Graphical Abstract Determination of natural estrogenic compounds in water by magnetic solid phase extraction followed by liquid chromatography-tandem mass spectrometry analysis.

  14. PESTICIDE MEASUREMENTS FROM THE FIRST NATIONAL ENVIRONMENTAL HEALTH SURVEY OF CHILD CARE CENTERS USING A MULTI-RESIDUE GC/MS ANALYSIS METHOD

    EPA Science Inventory

    The US Department of Housing and Urban Development, in collaboration with the US Consumer Product Safety Commission and the US Environmental Protection Agency, characterized the environments of young children (<6 years) by measuring lead, allergens, and pesticides in a randomly-s...

  15. Simultaneous determination of sulfonamides, penicillins and coccidiostats in pork by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Nebot, C; Regal, P; Miranda, J; Cepeda, A; Fente, C

    2012-05-01

    Veterinary drugs are widely and legally used to treat and prevent disease in livestock. However, drugs are also used illegally as growth-promoting agents. To protect the health of consumers, maximum residue limits (MRL) in food of animal origin have been established and are listed in Regulation 37/2010. According to this regulation, more than 300 drugs need to be controlled regularly in laboratories for residues of veterinary drugs. A cost-effective analytical method is very important and explains why the development of multi-residual methods is becoming popular in laboratories. The aim of this work is to describe a simple, rapid and economical high-performance liquid chromatography-tandem mass spectrometry method for the simultaneous identification and quantification of 21 veterinary drugs in pork muscle samples. The sample clean-up procedure is performed with acidified dichloromethane and does not require solid phase extraction. The method is applicable to nine sulfonamides and seven coccidiostats identified within 36 min. Calculated relevant validation parameters such as recoveries (from 72.to 126 %), intra-precision and intermediate precision (relative standard deviation below 40 %) and decision limits (below 7 µg Kg(-1)) were within acceptable range and in compliance with the requirements of Commission Decision 2002/657/EC. © The Author [2012]. Published by Oxford University Press. All rights reserved.

  16. Multi-residue screening of prioritised human pharmaceuticals, illicit drugs and bactericides in sediments and sludge.

    PubMed

    Langford, Katherine H; Reid, Malcolm; Thomas, Kevin V

    2011-08-01

    A robust multi-residue method was developed for the analysis of a selection of pharmaceutical compounds, illicit drugs and personal care product bactericides in sediments and sludges. Human pharmaceuticals were selected for analysis in Scottish sewage sludge and freshwater sediments based on prescription, physico-chemical and occurrence data. The method was suitable for the analysis of the selected illicit drugs amphetamine, benzoylecgonine, cocaine, and methamphetamine, the pharmaceuticals atenolol, bendroflumethiazide, carbamazepine, citalopram, diclofenac, fluoxetine, ibuprofen, and salbutamol, and the bactericides triclosan and triclocarban in sewage sludge and freshwater sediment. The method provided an overall recovery of between 56 and 128%, RSDs of between 2 and 19% and LODs of between 1 and 50 ng g(-1). Using the methodology the human pharmaceuticals atenolol, carbamazepine and citalopram and the bactericides triclosan and triclocarban were detected in Scottish sewage sludge. The illicit drugs cocaine, its metabolite benzoylecgonine, amphetamine and methamphetamine were not detected in any of the samples analysed. Triclosan and triclocarban were present at the highest concentrations with triclocarban detected in all but one sample and showing a pattern of co-occurrence in both sludge and sediment samples.

  17. Evaluation of zirconium dioxide-based sorbents to decrease the matrix effect in avocado and almond multiresidue pesticide analysis followed by gas chromatography tandem mass spectrometry.

    PubMed

    Lozano, Ana; Rajski, Łukasz; Uclés, Samanta; Belmonte-Valles, Noelia; Mezcua, Milagros; Fernández-Alba, Amadeo R

    2014-01-01

    Two sorbents containing ZrO₂ (Z-Sep and Z-Sep+) were tested as a d-SPE clean-up in combination with the QuEChERS and ethyl acetate multiresidue method in the pesticide residues extraction in avocado. All extracts were analysed using gas chromatography coupled with a triple quadrupole mass spectrometer working in multi-reaction monitoring mode. GC QToF was used to compare the amount of matrix compounds present in the final extracts, prepared according to different protocols. The highest number of pesticides with acceptable recoveries and the lowest amount of coextracted matrix compounds were provided by QuEChERS with Z-Sep. Subsequently, this method was fully validated in avocado and almonds. Validation studies were carried out according to DG Sanco guidelines including: the evaluation of recoveries at two levels (10 and 50 μg/kg), limit of quantitation, linearity, matrix effects, as well as interday and intraday precision. In avocado, 166 pesticides were fully validated compared to 119 in almonds. The method was operated satisfactorily in routine analysis and was applied to real samples. © 2013 Published by Elsevier B.V.

  18. Chitosan from shrimp shells: A renewable sorbent applied to the clean-up step of the QuEChERS method in order to determine multi-residues of veterinary drugs in different types of milk.

    PubMed

    Arias, Jean Lucas de Oliveira; Schneider, Antunielle; Batista-Andrade, Jahir Antonio; Vieira, Augusto Alves; Caldas, Sergiane Souza; Primel, Ednei Gilberto

    2018-02-01

    Clean extracts are essential in LC-MS/MS, since the matrix effect can interfere in the analysis. Alternative materials which can be used as sorbents, such as chitosan in the clean-up step, are cheap and green options. In this study, chitosan from shrimp shell waste was evaluated as a sorbent in the QuEChERS method in order to determine multi-residues of veterinary drugs in different types of milk, i. e., fatty matrices. After optimization, the method showed correlation coefficients above 0.99, LOQs ranged between 1 and 50μgkg -1 and recoveries ranged between 62 and 125%, with RSD<20% for all veterinary drugs in all types of milk under study. The clean-up step which employed chitosan proved to be effective, since it reduced both the matrix effect (from values between -40 and -10% to values from -10 to +10%) and the extract turbidity (up to 95%). When the proposed method was applied to different milk samples, residues of albendazole (49μgkg -1 ), sulfamethazine (

  19. Multiresidue analysis of sulfonamides, quinolones, and tetracyclines in animal tissues by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Zhiwen; Li, Xiaowei; Ding, Shuangyang; Jiang, Haiyang; Shen, Jianzhong; Xia, Xi

    2016-08-01

    A multiresidue method for the efficient identification and quantification of 38 compounds from 3 different classes of antibiotics (tetracyclines, sulfonamides, and quinolones) in animal tissues has been developed. The method optimization involved the selection of extraction solutions, comparison of different solid-phase extraction cartridges and different mobile phases. As a result, the samples were extracted with Mcllvaine and phosphate buffers, followed by clean-up step based on solid-phase extraction with Oasis HLB cartridge. All compounds were determined by ultra-high performance liquid chromatography-tandem mass spectrometry, in one single injection with a chromatographic run time of only 9min. The method efficiency was evaluated in 5 tissues including muscle, liver, and kidney, and the mean recoveries ranged from 54% to 102%, with inter-day relative standard deviation lower than 14%. The limits of quantification were between 0.5 and 10μg/kg, which were satisfactory to support future surveillance monitoring. The developed method was applied to the analysis of swine liver and chicken samples from local markets, and sulfamethazine was the most commonly detected compound in the animal samples, with the highest residue level of 998μg/kg. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Study of different HILIC, mixed-mode, and other aqueous normal-phase approaches for the liquid chromatography/mass spectrometry-based determination of challenging polar pesticides.

    PubMed

    Vass, Andrea; Robles-Molina, José; Pérez-Ortega, Patricia; Gilbert-López, Bienvenida; Dernovics, Mihaly; Molina-Díaz, Antonio; García-Reyes, Juan F

    2016-07-01

    The aim of the study was to evaluate the performance of different chromatographic approaches for the liquid chromatography/mass spectrometry (LC-MS(/MS)) determination of 24 highly polar pesticides. The studied compounds, which are in most cases unsuitable for conventional LC-MS(/MS) multiresidue methods were tested with nine different chromatographic conditions, including two different hydrophilic interaction liquid chromatography (HILIC) columns, two zwitterionic-type mixed-mode columns, three normal-phase columns operated in HILIC-mode (bare silica and two silica-based chemically bonded columns (cyano and amino)), and two standard reversed-phase C18 columns. Different sets of chromatographic parameters in positive (for 17 analytes) and negative ionization modes (for nine analytes) were examined. In order to compare the different approaches, a semi-quantitative classification was proposed, calculated as the percentage of an empirical performance value, which consisted of three main features: (i) capacity factor (k) to characterize analyte separation from the void, (ii) relative response factor, and (iii) peak shape based on analytes' peak width. While no single method was able to provide appropriate detection of all the 24 studied species in a single run, the best suited approach for the compounds ionized in positive mode was based on a UHPLC HILIC column with 1.8 μm particle size, providing appropriate results for 22 out of the 24 species tested. In contrast, the detection of glyphosate and aminomethylphosphonic acid could only be achieved with a zwitterionic-type mixed-mode column, which proved to be suitable only for the pesticides detected in negative ion mode. Finally, the selected approach (UHPLC HILIC) was found to be useful for the determination of multiple pesticides in oranges using HILIC-ESI-MS/MS, with limits of quantitation in the low microgram per kilogram in most cases. Graphical Abstract HILIC improves separation of multiclass polar pesticides.

  1. Development of a new multi-residue laser diode thermal desorption atmospheric pressure chemical ionization tandem mass spectrometry method for the detection and quantification of pesticides and pharmaceuticals in wastewater samples.

    PubMed

    Boisvert, Michel; Fayad, Paul B; Sauvé, Sébastien

    2012-11-19

    A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants in wastewater (atrazine, desethylatrazine, 17β-estradiol, ethynylestradiol, norethindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole). We specifically included pharmaceutical compounds from multiple therapeutic classes, as well as pesticides. Sample pre-concentration and clean-up was performed using a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties, followed by analysis by laser diode thermal desorption atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD interface is a new high-throughput sample introduction method, which reduces total analysis time to less than 15s per sample as compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC-MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of the stationary phase, the loading flow rate, the extraction pH, the volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from the primary sedimentation tank of a municipal wastewater treatment plant. Recoveries of target compounds from wastewater ranged from 78% to 106%, the limit of detection ranged from 30 to 122ng L(-1) while the limit of quantification ranged from 90 to 370ng L(-1). Calibration curves in the wastewater matrix showed good linearity (R(2)≥0.991) for all target analytes and the intraday and interday coefficient of variation was below 15%, reflecting a good precision. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous determination of sulfonamides, trimethoprim and dapsone in muscle, egg, milk and honey.

    PubMed

    Varenina, Ivana; Bilandžić, Nina; Kolanović, Božica Solomun; Božić, Đurđica; Sedak, Marija; Đokić, Maja; Varga, Ines

    2016-01-01

    A quantitative multi-residue method that includes 13 sulfonamides, trimethoprim and dapsone was developed and validated according to Commission Decision 2002/657/EC for muscle, milk egg and honey samples. For all matrices, the same extraction procedure was used. Samples were extracted with an acetone/dichloromethane mixture and cleaned up on aromatic sulfonic acid (SO3H) SPE cartridges. After elution and concentration steps, analytes were identified and quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Data were acquired according to the multiple reaction-monitoring approach (MRM) and analytes were quantified both by the isotope dilution and the matrix-matched approaches calculating the response factors for the scanned product ions. The developed method shows good linearity, specificity, precision (repeatability and within-laboratory reproducibility), and trueness. Estimated CCβ for sulfonamides ranged between 5.6 and 8.2 µg kg(-1) for eggs, between 11.1 and 69.9 µg kg(-1) for milk, between 64.7 and 87.9 µg kg(-1) for muscle, and between 2.7 and 5.3 µg kg(-1) for honey. CCβ values for dapsone were 3.1, 0.6, 0.7 and 1.5 µg kg(-1) and for trimethoprim were 3.1, 6.7, 81.7 and 3.0 µg kg(-1) calculated for eggs, milk, muscle and honey, respectively. Recovery for all matrices was in the range from 89.1% and 109.7%. In matrix effect testing, no significant deviations were found between different samples of muscle and milk; however, a matrix effect was observed when testing different types of honey. The validation results demonstrate that the method is suitable for routine veterinary drug analysis and confirmation of suspect samples.

  3. Development of an analytical method for the targeted screening and multi-residue quantification of environmental contaminants in urine by liquid chromatography coupled to high resolution mass spectrometry for evaluation of human exposures.

    PubMed

    Cortéjade, A; Kiss, A; Cren, C; Vulliet, E; Buleté, A

    2016-01-01

    The aim of this study was to develop an analytical method and contribute to the assessment of the Exposome. Thus, a targeted analysis of a wide range of contaminants in contact with humans on daily routines in urine was developed. The method focused on a list of 38 contaminants, including 12 pesticides, one metabolite of pesticide, seven veterinary drugs, five parabens, one UV filter, one plastic additive, two surfactants and nine substances found in different products present in the everyday human environment. These contaminants were analyzed by high performance liquid chromatography coupled to high resolution mass spectrometry (HPLC-HRMS) with a quadrupole-time-of-flight (QqToF) instrument from a raw urinary matrix. A validation according to the FDA guidelines was employed to evaluate the specificity, linear or quadratic curve fitting, inter- and intra-day precision, accuracy and limits of detection and quantification (LOQ). The developed analysis allows for the quantification of 23 contaminants in the urine samples, with the LOQs ranging between 4.3 ng.mL(-1) and 113.2 ng.mL(-1). This method was applied to 17 urine samples. Among the targeted contaminants, four compounds were detected in samples. One of the contaminants (tributyl phosphate) was detected below the LOQ. The three others (4-hydroxybenzoic acid, sodium dodecylbenzenesulfonate and O,O-diethyl thiophosphate potassium) were detected but did not fulfill the validation criteria for quantification. Among these four compounds, two of them were found in all samples: tributyl phosphate and the surfactant sodium dodecylbenzenesulfonate. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Multiresidue analysis of 36 pesticides in soil using a modified quick, easy, cheap, effective, rugged, and safe method by liquid chromatography with tandem quadruple linear ion trap mass spectrometry.

    PubMed

    Feng, Xue; He, Zeying; Wang, Lu; Peng, Yi; Luo, Ming; Liu, Xiaowei

    2015-09-01

    A new method for simultaneous determination of 36 pesticides, including 15 organophosphorus, six carbamate, and some other pesticides in soil was developed by liquid chromatography with tandem quadruple linear ion trap mass spectrometry. The extraction and clean-up steps were optimized based on the quick, easy, cheap, effective, rugged, and safe method. The data were acquired in multiple reaction monitoring mode combined with enhanced product ion to increase confidence of the analytical results. Validation experiments were performed in soil samples. The average recoveries of pesticides at four spiking levels (1, 5, 50, and 100 μg/kg) ranged from 63 to 126% with relative standard deviation below 20%. The limits of detection of pesticides were 0.04-0.8 μg/kg, and the limits of quantification were 0.1-2.6 μg/kg. The correlation coefficients (r(2) ) were higher than 0.990 in the linearity range of 0.5-200 μg/L for most of the pesticides. The method allowed for the analysis of the target pesticides in the lower μg/kg concentration range. The optimized method was then applied to the test of real soil samples obtained from several areas in China, confirming the feasibility of the method. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Evaluation of various QuEChERS based methods for the analysis of herbicides and other commonly used pesticides in polished rice by LC-MS/MS.

    PubMed

    Pareja, Lucía; Cesio, Verónica; Heinzen, Horacio; Fernández-Alba, Amadeo R

    2011-02-15

    Four different extraction and clean-up protocols based on the QuEChERS method were compared for the development of an optimized sample preparation procedure for the multiresidue analysis of 16 commonly applied herbicides in rice crops using LC-QqQ/MS. Additionally the methods were evaluated for the analysis of 26 insecticides and fungicides currently used in rice crops. The methods comprise, in general, the hydratation of the sample with water followed by the extraction with acetonitrile, phase separation with the addition of different salts and finally a clean-up step with various sorbents. Matrix effects were evaluated for the 4 studied methods using LC-QqQ/MS. Additionally LC-TOF/MS was used to compare the co-extractants obtained with the four assayed methodologies. Thirty-six pesticides presented good performance with recoveries in the range 70-120% and relative standard deviations below 20% using 7.5 g of milled polished rice and the buffered acetate QuEChERS method without clean-up at both fortification levels: 10 and 300 μg kg(-1). The other six pesticides presented low recovery rates, nevertheless all these analytes could be analyzed with at least one of the other three studied procedures. Copyright © 2010. Published by Elsevier B.V.

  6. Comparison of veterinary drug residue results in animal tissues by ultrahigh-performance liquid chromatography coupled to triple quadrupole or quadrupole-time-of-flight tandem mass spectrometry after different sample preparation methods, including use of a commercial lipid removal product.

    PubMed

    Anumol, Tarun; Lehotay, Steven J; Stevens, Joan; Zweigenbaum, Jerry

    2017-04-01

    Veterinary drug residues in animal-derived foods must be monitored to ensure food safety, verify proper veterinary practices, enforce legal limits in domestic and imported foods, and for other purposes. A common goal in drug residue analysis in foods is to achieve acceptable monitoring results for as many analytes as possible, with higher priority given to the drugs of most concern, in an efficient and robust manner. The U.S. Department of Agriculture has implemented a multiclass, multi-residue method based on sample preparation using dispersive solid phase extraction (d-SPE) for cleanup and ultrahigh-performance liquid chromatography-tandem quadrupole mass spectrometry (UHPLC-QQQ) for analysis of >120 drugs at regulatory levels of concern in animal tissues. Recently, a new cleanup product called "enhanced matrix removal for lipids" (EMR-L) was commercially introduced that used a unique chemical mechanism to remove lipids from extracts. Furthermore, high-resolution quadrupole-time-of-flight (Q/TOF) for (U)HPLC detection often yields higher selectivity than targeted QQQ analyzers while allowing retroactive processing of samples for other contaminants. In this study, the use of both d-SPE and EMR-L sample preparation and UHPLC-QQQ and UHPLC-Q/TOF analysis methods for shared spiked samples of bovine muscle, kidney, and liver was compared. The results showed that the EMR-L method provided cleaner extracts overall and improved results for several anthelmintics and tranquilizers compared to the d-SPE method, but the EMR-L method gave lower recoveries for certain β-lactam antibiotics. QQQ vs. Q/TOF detection showed similar mixed performance advantages depending on analytes and matrix interferences, with an advantage to Q/TOF for greater possible analytical scope and non-targeted data collection. Either combination of approaches may be used to meet monitoring purposes, with an edge in efficiency to d-SPE, but greater instrument robustness and less matrix effects when analyzing EMR-L extracts. Graphical abstract Comparison of cleanup methods in the analysis of veterinary drug residues in bovine tissues.

  7. Determination of 82 veterinary drugs in swine waste lagoon sludge by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Xiaowei; Guo, Ping; Shan, Yawen; Ke, Yuebin; Li, Hui; Fu, Qin; Wang, Yingyu; Liu, Tianhe; Xia, Xi

    2017-05-26

    This work reports the development of a multi-residue method for the identification and quantification of 82 veterinary drugs belonging to different chemical classes in swine waste lagoon. The proposed method applies a solid-phase extraction procedure with Oasis PRiME HLB cartridges that combines isolation of the compounds and sample clean-up in a single step. Analysis is performed by ultra-high performance liquid chromatography-tandem mass spectrometry, in one single injection with a chromatographic run time of only 9.5min. Linearity was studied in the range between 1 and 500μgkg -1 using standards prepared both in pure solvent and in the presence of matrix, showing coefficients of determination higher than 0.99 for all the analytes except for cefapirin in matrix. The average recoveries were in the range of 60-110% for most of the compounds tested with inter-day relative standard deviations below 17%. More than 97% of the investigated compounds had less or equal to a 5μgkg -1 quantitation limit in the studied matrix. Finally, the method was used with success to detect and quantify veterinary drugs residues in real samples with sulfonamides, quinolones, and tetracyclines being the most frequently determined compound groups. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Simultaneous determination of multiclass emerging contaminants in aquatic plants by ultrasound-assisted matrix solid-phase dispersion and GC-MS.

    PubMed

    Aznar, Ramón; Albero, Beatriz; Sánchez-Brunete, Consuelo; Miguel, Esther; Martín-Girela, Isabel; Tadeo, José L

    2017-03-01

    A multiresidue method was developed for the simultaneous determination of 31 emerging contaminants (pharmaceutical compounds, hormones, personal care products, biocides, and flame retardants) in aquatic plants. Analytes were extracted by ultrasound-assisted matrix solid-phase dispersion (UA-MSPD) and determined by gas chromatography-mass spectrometry after sylilation, The method was validated for different aquatic plants (Typha angustifolia, Arundo donax, and Lemna minor) and a semiaquatic cultivated plant (Oryza sativa) with good recoveries at concentrations of 100 and 25 ng g -1 wet weight, ranging from 70 to 120 %, and low method detection limits (0.3 to 2.2 ng g -1 wet weight). A significant difference of the chromatographic response was observed for some compounds in neat solvent versus matrix extracts, and therefore, quantification was carried out using matrix-matched standards in order to overcome this matrix effect. Aquatic plants taken from rivers located at three Spanish regions were analyzed, and the compounds detected were parabens, bisphenol A, benzophenone-3, cyfluthrin, and cypermethrin. The levels found ranged from 6 to 25 ng g -1 wet weight except for cypermethrin that was detected at 235 ng g -1 wet weight in O. sativa samples.

  9. Development and Validation of a Multiresidue Method for the Determination of Pesticides in Dry Samples (Rice and Wheat Flour) Using Liquid Chromatography/Triple Quadrupole Tandem Mass Spectrometry.

    PubMed

    Grande-Martínez, Ángel; Arrebola, Francisco Javier; Moreno, Laura Díaz; Vidal, José Luis Martínez; Frenich, Antonia Garrido

    2015-01-01

    A rapid and sensitive multiresidue method was developed and validated for the determination of around 100 pesticides in dry samples (rice and wheat flour) by ultra-performance LC coupled to a triple quadrupole mass analyzer working in tandem mode (UPLC/QqQ-MS/MS). The sample preparation step was optimized for both matrixes. Pesticides were extracted from rice samples using aqueous ethyl acetate, while aqueous acetonitrile extraction [modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method] was used for wheat flour matrixes. In both cases the extracts were then cleaned up by dispersive solid phase extraction with MgSO4 and primary secondary amine+C18 sorbents. A further cleanup step with Florisil was necessary to remove fat in wheat flour. The method was validated at two concentration levels (3.6 and 40 μg/kg for most compounds), obtaining recoveries ranging from 70 to 120%, intraday and interday precision values≤20% expressed as RSDs, and expanded uncertainty values≤50%. The LOQ values ranged between 3.6 and 20 μg/kg, although it was set at 3.6 μg/kg for the majority of the pesticides. The method was applied to the analysis of 20 real samples, and no pesticides were detected.

  10. Multi-residue method for the determination of antibiotics and some of their metabolites in seafood.

    PubMed

    Serra-Compte, Albert; Álvarez-Muñoz, Diana; Rodríguez-Mozaz, Sara; Barceló, Damià

    2017-06-01

    The presence of antibiotics in seafood for human consumption may pose a risk for consumers. A methodology for the analysis of antibiotics in seafood based on QuEChERS (quick, easy, cheap, effective, rugged, and safe) extraction, followed by detection and quantification using liquid chromatography coupled to mass spectrometry was developed. The analytical method was evaluated for the determination of 23 antibiotics (including parent compounds and some metabolites) in fish, mussels and clams. Recoveries ranged between 30% and 70% for most of the compounds and method detection and quantification limits (MDLs and MQLs) were between 0.01 and 0.31 ng/g dry weigh (dw) and 0.02-1.03 ng/g (dw) respectively. Real seafood samples were analysed using this method. Nine antibiotics were found at levels above MDLs; however none of them exceed the maximum residue limits (MRL) established by the authorities. Tetracycline was the most ubiquitous compound, presenting also the highest concentration: 5.63 ng/g (dw) in fish from Netherlands. In addition, an alternative technique based on microbial growth inhibition was explored as semiquantitative detection method of antibiotics in seafood. This methodology could be applied as a fast screening technique for the detection of macrolides and β-lactams in seafood but further research is needed for other antibiotics families. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Combination of solvent extractants for dispersive liquid-liquid microextraction of fungicides from water and fruit samples by liquid chromatography with tandem mass spectrometry.

    PubMed

    Pastor-Belda, Marta; Garrido, Isabel; Campillo, Natalia; Viñas, Pilar; Hellín, Pilar; Flores, Pilar; Fenoll, José

    2017-10-15

    A multiresidue method was developed to determine twenty-five fungicides belonging to three different chemical families, oxazoles, strobilurins and triazoles, in water and fruit samples, using dispersive liquid-liquid microextraction (DLLME) and liquid chromatography/tandem mass spectrometry (LC-MS 2 ). Solid-liquid extraction with acetonitrile was used for the analysis in fruits, the extract being used as dispersant solvent in DLLME. Since some of the analytes showed high affinity for chloroform and the others were more efficiently extracted with undecanol, a mixture of both solvents was used as extractant in DLLME. After evaporation of CHCl 3 , the enriched phase was analyzed. Enrichment factors in the 23-119 and 12-60 ranges were obtained for waters and fruits, respectively. The approach was most sensitive for metominostrobin with limits of quantification of 1ngL -1 and 5ngkg -1 in waters and fruits, respectively, while a similar sensitivity was attained for tebuconazole in fruits. Recoveries of the fungicides varied between 86 and 116%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Using In Silico Fragmentation to Improve Routine Residue Screening in Complex Matrices.

    PubMed

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Walker, Stephan; Widmer, Mirjam

    2017-12-01

    Targeted residue screening requires the use of reference substances in order to identify potential residues. This becomes a difficult issue when using multi-residue methods capable of analyzing several hundreds of analytes. Therefore, the capability of in silico fragmentation based on a structure database ("suspect screening") instead of physical reference substances for routine targeted residue screening was investigated. The detection of fragment ions that can be predicted or explained by in silico software was utilized to reduce the number of false positives. These "proof of principle" experiments were done with a tool that is integrated into a commercial MS vendor instrument operating software (UNIFI) as well as with a platform-independent MS tool (Mass Frontier). A total of 97 analytes belonging to different chemical families were separated by reversed phase liquid chromatography and detected in a data-independent acquisition (DIA) mode using ion mobility hyphenated with quadrupole time of flight mass spectrometry. The instrument was operated in the MS E mode with alternating low and high energy traces. The fragments observed from product ion spectra were investigated using a "chopping" bond disconnection algorithm and a rule-based algorithm. The bond disconnection algorithm clearly explained more analyte product ions and a greater percentage of the spectral abundance than the rule-based software (92 out of the 97 compounds produced ≥1 explainable fragment ions). On the other hand, tests with a complex blank matrix (bovine liver extract) indicated that the chopping algorithm reports significantly more false positive fragments than the rule based software. Graphical Abstract.

  13. Using In Silico Fragmentation to Improve Routine Residue Screening in Complex Matrices

    NASA Astrophysics Data System (ADS)

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Walker, Stephan; Widmer, Mirjam

    2017-12-01

    Targeted residue screening requires the use of reference substances in order to identify potential residues. This becomes a difficult issue when using multi-residue methods capable of analyzing several hundreds of analytes. Therefore, the capability of in silico fragmentation based on a structure database ("suspect screening") instead of physical reference substances for routine targeted residue screening was investigated. The detection of fragment ions that can be predicted or explained by in silico software was utilized to reduce the number of false positives. These "proof of principle" experiments were done with a tool that is integrated into a commercial MS vendor instrument operating software (UNIFI) as well as with a platform-independent MS tool (Mass Frontier). A total of 97 analytes belonging to different chemical families were separated by reversed phase liquid chromatography and detected in a data-independent acquisition (DIA) mode using ion mobility hyphenated with quadrupole time of flight mass spectrometry. The instrument was operated in the MSE mode with alternating low and high energy traces. The fragments observed from product ion spectra were investigated using a "chopping" bond disconnection algorithm and a rule-based algorithm. The bond disconnection algorithm clearly explained more analyte product ions and a greater percentage of the spectral abundance than the rule-based software (92 out of the 97 compounds produced ≥1 explainable fragment ions). On the other hand, tests with a complex blank matrix (bovine liver extract) indicated that the chopping algorithm reports significantly more false positive fragments than the rule based software. [Figure not available: see fulltext.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ikonomou, M.G.; Crewe, N.F.; Fischer, M.

    It has been demonstrated that marine mammals accumulate high concentrations of lipophilic organochlorine contaminants in blubber. As predators of the high trophic level they have also been used to evaluate contamination in the marine environment. Sampling of living marine mammals using a microsample (100 to 200 mg) biopsy dart technique offers a potentially invaluable chronicle in assessing levels and types of persistent environmental pollutants from a sample in which age, sex and other genetic information can additionally be ascertained. The authors have explored analytical methodology based on a high sensitivity detection system (HRGC/HRMS) which provides multi-residue determinations from biopsy dartmore » microsamples. Lipid content and the concentrations of PCDDs, PCDFs and non-ortho and mono-ortho substituted PCBs were measured in 100 mg biopsy dart replicates taken from a killer whale carcass and in three strata of the blubber of that carcass. Statistically acceptable results were obtained from the dart replicates which compared very well with those of the blubber strata. Analytical data from 100 mg extractions from an established in house blubber CRM also compared well against a series of 2.5 g extractions of that CRM. The extraction and cleanup procedures used also allow for the determination of other organohalogen contaminants such as DDT and other pesticides, all the remaining PCBs, polychlorinated diphenylethers and brominated residues. The strengths and limitations of the analytical methodology and the biopsy dart as a sampling tool and pollution predicator will be illustrated in terms of method accuracy and precision, glassware and procedural blanks associated with each extraction batch, and the incorporation of an in house micro reference standard.« less

  15. Multiresidue determination of ten nonsteroidal anti-inflammatory drugs in bovine, porcine, and chicken liver tissues by HPLC-MS/MS.

    PubMed

    Kang, JeongWoo; Park, Su-Jeong; Park, Hae-Chul; Gedi, Vinayakumar; So, ByungJae; Lee, Kwang-Jick

    2014-09-01

    Nonsteroidal anti-inflammatory drugs (NSAIDs) are the group of drugs having the therapeutic efficacy of analgesic and antipyretic. To detect health-threatening residues of NSAIDs, a fast and easy multiresidue method based on liquid chromatography tandem mass spectrometry (LC-MS/MS) was described. Ten NSAIDs were extracted from the tissues using 2 mL of acetonitrile and 0.1 mL of 2 mM ammonium formate in distilled water. After clean-up using C18 sorbent, it was evaporated under nitrogen, reconstituted with 1 mL distilled water and analyzed by LC-MS/MS. The method was validated based on guideline for residue testing laboratory. Furthermore, the method has also been applied successfully to detect ten NSAIDs from bovine, porcine, and chicken liver tissues. In a total of 315 liver samples tested, acetylic salicylic acid was detected from 28 porcine and 2 chicken liver tissues at levels of 13 ∼ 576 and 50 ∼ 53 ng/g, respectively. Subsequently, paracetamol was detected in 15 porcine liver tissues with a detection levels of 28 ∼ 381 ng/g. Phenylbutazone and its metabolite, oxyphenylbutazone, were detected at 247 and 15 ng/g range in one of the bovine liver tissue, respectively.

  16. Development and validation of rapid multiresidue and multi-class analysis for antibiotics and anthelmintics in feed by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Robert, Christelle; Brasseur, Pierre-Yves; Dubois, Michel; Delahaut, Philippe; Gillard, Nathalie

    2016-08-01

    A new multi-residue method for the analysis of veterinary drugs, namely amoxicillin, chlortetracycline, colistins A and B, doxycycline, fenbendazole, flubendazole, ivermectin, lincomycin, oxytetracycline, sulfadiazine, tiamulin, tilmicosin and trimethoprim, was developed and validated for feed. After acidic extraction, the samples were centrifuged, purified by SPE and analysed by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry. Quantitative validation was done in accordance with the guidelines laid down in European Commission Decision 2002/657/CE. Matrix-matched calibration with internal standards was used to reduce matrix effects. The target level was set at the authorised carryover level (1%) and validation levels were set at 0.5%, 1% and 1.5%. Method performances were evaluated by the following parameters: linearity (0.986 < R(2) < 0.999), precision (repeatability < 12.4% and reproducibility < 14.0%), accuracy (89% < recovery < 107%), sensitivity, decision limit (CCα), detection capability (CCβ), selectivity and expanded measurement uncertainty (k = 2).This method has been used successfully for three years for routine monitoring of antibiotic residues in feeds during which period 20% of samples were found to exceed the 1% authorised carryover limit and were deemed non-compliant.

  17. [Analysis of sulfonamide residues in pork and chicken by high performance liquid chromatography coupled with solid-phase extraction using multiwalled carbon nanotubes as adsorbent].

    PubMed

    Zhao, Haixiang; Liu, Haiping; Yan, Zaoying

    2014-03-01

    A multi-residue analytical method based on solid-phase extraction (SPE) with multiwalled carbon nanotubes (MWCNTs) as sorbent was developed. The determination of the sulfonamides (SAs) in pork and chicken was carried out by high performance liquid chromatography-ultraviolet detection (HPLC-UV). The clean-up conditions were optimized. The analytes were extracted by acetonitril and cleaned-up by MWCNTs SPE cartridge. The extract was redissolved with the Na2HPO4 buffer (pH 5.5-6.0) for loading, and was washed with acetone-hexane (5:95, v/v), then eluted with acetone-dichloromethane (1:1, v/v) from the column. The mobile phase used in the chromatographic separation consisted of a binary mixture of acetonitrile and 50 mmol/L NaH2PO4 with the volume ratio of 7:3. A wide linear range was 0.01-1.00 mg/L with the correlation coefficients above 0.998. The limits of detection (S/N = 3) were 0.003 mg/L, and the limits of quantification (S/N = 10) were 0.01 mg/L. The average recoveries were over 70% for the nine SAs in the spiked range of 0.02-0.2 mg/kg, with the relative standard deviations (RSDs) lower than 8%. This study indicated that the MWCNTs SPE cartridge is efficient for the clean-up of the SAs in animal tissues or products, and the method is simple, accurate and suitable for the quantification of the SAs residues.

  18. A Rapid Method for the Quantitative Determination of 34 Pesticides in Nonalcoholic Carbonated Beverages Using Liquid-Liquid Extraction Coupled to Dispersive Solid-Phase Cleanup Followed by Gas Chromatography with Tandem Mass Spectrometry.

    PubMed

    Rai, Satyajeet; Gullapalli, Madhuri Devi; Srivastava, Anshuman; Shaik, Hussain; Siddiqui, Mohammed Haris; Mudiam, Mohana Krishna Reddy

    2017-05-01

    An economical, rapid, and sensitive multiresidue method using liquid-liquid extraction (LLE) coupled with dispersive SPE (dSPE) cleanup was developed for the quantitative determination of 34 multiclass multiresidue (MCMR) pesticides (14 organochlorines, eight organophosphates, 10 synthetic pyrethroids, and two herbicides) in nonalcoholic carbonated beverages (cola, orange, lemon-lime, and citra) using GC with tandem MS. The procedure mainly involved LLE by dichloromethane and dSPE cleanup in the presence of magnesium sulfate, primary secondary amine, and C18. The RSD of the developed method was found to be less than 14%. The LOD and LOQ values for all the analyzed pesticides were found in the ranges of 0.001-0.027 μg/L and 0.004-0.088 μg/L, respectively. The LOQ levels of the pesticides analyzed were found to be well below the recommended limit by the European Union (0.1 μg/L in water). The mean recoveries of pesticides in different nonalcoholic carbonated beverages (cola, orange, lemon-lime, and citra) were found to be in the range of 79-111%, with RSDs less than 11%. The validation data prove that the method can be acceptable to regulatory agencies for the routine analysis of MCMR pesticides in nonalcoholic carbonated beverages.

  19. Development of an ultra-high-pressure liquid chromatography-tandem mass spectrometry multi-residue sulfonamide method and its application to water, manure slurry, and soils from swine rearing facilities.

    PubMed

    Shelver, Weilin L; Hakk, Heldur; Larsen, Gerald L; DeSutter, Thomas M; Casey, Francis X M

    2010-02-19

    An analytical method was developed using ultra-high-pressure liquid chromatography-triple quadrupole-tandem mass spectrometry (UHPLC-TQ-MS/MS) to simultaneously analyze 14 sulfonamides (SA) in 6 min. Despite the rapidity of the assay the system was properly re-equilibrated in this time. No carryover was observed even after high analyte concentrations. The instrumental detection limit based on signal-to-noise ratio (S/N)>3, was below 1 pg/microL (5 pg on column) for all SAs except sulfachloropyridazine. Surface water, ground water, soil, and slurry manure contained in storage ponds in and around swine [Sus scrofa domesticus] rearing facilities were analyzed. Sample cleanup for ground water and surface water included using solid phase extraction (SPE) using Oasis hydrophilic-lipophilic balance (HLB) cartridges. The soil and slurry manure required tandem strong anion exchange (SAX) and HLB solid phase extraction cartridges for sample cleanup. With few exceptions, the recoveries ranged from 60 to 100% for all matrices. The minimum detectable levels were below 2.0 ng/L for water, 30 ng/L for slurry manure, and 45 ng/kg for soil except for sulfachloropyridazine. The coefficient of variation (CV) was within 20% for most of the compounds analyzed. Using this method, sulfamethazine concentrations of 2250-5060 ng/L, sulfamethoxazole concentrations of 108-1.47 x 10(6)ng/L, and sulfathiazole concentrations of 785-1700 ng/L were found in the slurry manure. Sulfadimethoxine (2.0-32 ng/L), sulfamethazine (2.0-5.1 ng/L), and sulfamethoxazole (20.5-43.0 ng/L) were found in surface water and ground water. In top soil (0-15 cm), sulfamethazine ranged 34.5-663 ng/kg dry weight in those locations that received slurry manure as a nutrient; no SAs were found in the soil depths between 46 and 61 cm. The speed makes the method practical for medium to high throughput applications. The sensitivity and positive analyte identification make the method suitable for the demanding requirements for real world applications. Published by Elsevier B.V.

  20. Quantitative Multiclass Pesticide Residue Analysis in Apple, Pear, and Grape by Modified QuEChERS and Liquid Chromatography Coupled to High-Resolution Mass Spectrometry.

    PubMed

    Munaretto, Juliana S; Viera, Mariela de S; Martins, Manoel L; Adaime, Martha B; Zanella, Renato

    2016-11-01

    Most of the analytical methods currently applied in food control laboratories are focused on the determination of target compounds using LC coupled to tandem MS, which is an effective technique, but low-resolution MS is limited. Thus, a method for determination of pesticide multiresidues in fruits (pear, apple, and grape) using a modified quick, easy, cheap, effective, rugged, and safe method and LC coupled to quadrupole time-of-flight (Q-TOF) MS was developed and validated. The proposed method showed good linearity (r2 > 0.99) from 1 to 100 μg/L. Recoveries for blank samples spiked at 0.01, 0.04, and 0.10 mg/kg were between 66 and 122%, with RSDs <28%. Respective LOQs for apple, pear, and grape matrixes were 0.01 mg/kg for 112, 120, and 118 compounds, and 0.04 mg/kg for 22, 12, and 17 compounds, and average mass accuracy error was 3.2 ppm. LC with Q-TOF MS detection using protonated molecular ion and/or adducts and mass accuracy provided reliability for the method. The proposed method is effective for pesticide residue determination in apple, pear, and grape samples, proving that high-resolution MS using full scan mode can be a powerful and reliable technique for quantification purposes, being adequate for application in the surveillance of maximum residue limits set by different legislations.

  1. Multiresidue pesticide analysis of tuber and root commodities by QuEchERS extraction and ultra-performance liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Garrido Frenich, Antonia; Martín Fernández, María del Mar; Díaz Moreno, Laura; Martínez Vidal, Jose Lúis; López-Gutiérrez, Noelia

    2012-01-01

    A simple, rapid, and reliable multiresidue method to determine 84 pesticides in potato and carrot samples by ultra-performance liquid chromatography coupled to MS/MS has been developed and fully validated for routine analysis according to ISO/IEC 17025:2005. The method makes use of a buffered Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) sample preparation procedure based on a single extraction with acidified acetonitrile, followed by partitioning with salts. Chromatographic conditions were optimized in order to achieve a rapid separation in the multiple reaction monitoring mode. Performance characteristics of the method, including an estimation of measurement uncertainty using validation data, are reported for both matrixes. Calibration curves were linear from 0.010 to 0.150 mg/kg for most compounds. The LOD and LOQ were 0.006 and 0.010 mg/kg, respectively, except for fluorocloridone, fluquinconazol, and hexitiazox, which were 0.030 and 0.050 mg/kg, respectively. Recoveries obtained were in the range 70-116%, with intraday precision values < or = 20% RSD and interday precision values < or = 25% RSD at two different concentration levels. The overall uncertainty of the method was estimated at two concentrations as being lower than 34% in all cases. The method has been applied to the analysis of 70 vegetable samples, and imidacloprid and linuron were the pesticides most frequently found in potato and carrot commodities, respectively.

  2. Trace analysis of pesticides in paddy field water by direct injection using liquid chromatography-quadrupole-linear ion trap-mass spectrometry.

    PubMed

    Pareja, Lucía; Martínez-Bueno, M J; Cesio, Verónica; Heinzen, Horacio; Fernández-Alba, A R

    2011-07-29

    A multiresidue method was developed for the quantification and confirmation of 70 pesticides in paddy field water. After its filtration, water was injected directly in a liquid chromatograph coupled to a hybrid triple quadrupole-linear ion trap-mass spectrometer (QqLIT). The list of target analytes included organophosphates, phenylureas, sulfonylureas, carbamates, conazoles, imidazolinones and others compounds widely used in different countries where rice is cropped. Detection and quantification limits achieved were in the range from 0.4 to 80 ng L(-1) and from 2 to 150 ng L(-1), respectively. Correlation coefficients for the calibration curves in the range 0.1-50 μg L(-1) were higher than 0.99 except for diazinon (0.1-25 μg L(-1)). Only 9 pesticides presented more than 20% of signal suppression/enhancement, no matrix effect was observed in the studied conditions for the rest of the target pesticides. The method developed was used to investigate the occurrence of pesticides in 59 water samples collected in paddy fields located in Spain and Uruguay. The study shows the presence of bensulfuron methyl, tricyclazole, carbendazim, imidacloprid, tebuconazole and quinclorac in a concentration range from 0.08 to 7.20 μg L(-1). Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Simultaneous determination of UV-filters and estrogens in aquatic invertebrates by modified quick, easy, cheap, effective, rugged, and safe extraction and liquid chromatography tandem mass spectrometry.

    PubMed

    He, Ke; Timm, Anne; Blaney, Lee

    2017-08-04

    Ultraviolet-filters (UV-filters) and estrogens have attracted increased attention as contaminants of emerging concern (CECs) due to their widespread occurrence in the environment. Most of these CECs are hydrophobic and have the potential to accumulate in aquatic organisms. To date, co-analysis of UV-filters and estrogens has not been reported due, in part, to the complex environmental matrices. Here, a multi-residue method has been developed for simultaneous determination of five UV-filters and three estrogens in tissue from aquatic and marine organisms. The procedure involved a modified Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) extraction with a novel reverse-solid-phase extraction (reverse-SPE) cleanup in place of dispersive-SPE, followed by liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis. The tissue mass, acetonitrile content, and salt conditions for QuEChERS extraction, along with the reverse-SPE cartridge material and elution conditions, were thoroughly investigated and optimized. Five UV-filters (i.e., 3-(4-methylbenzylidene) camphor, benzophenone-3, ethylhexylmethoxycinnamate, homosalate, and octocrylene) and three estrogens (i.e., estrone, 17β-estradiol, and 17α-ethinylestradiol) were simultaneously analyzed by taking advantage of wrong-way-round ionization in LC-MS/MS. The optimized analytical protocol exhibited good recoveries (>80%) for target compounds and enabled their detection at concentrations as low as 0.2ng/g in 50mg tissue samples. The method was applied to determine concentrations of target analytes in four invertebrates (i.e., Orconectes virilis, Procambarus clarkii, Crassostrea virginica, and Ischadium recurvum). All eight target analytes were detected at least once in the tissue samples, with the highest concentration being 399ng/g of homosalate in O. virilis. These results highlight the ubiquitous bioaccumulation of CECs in aquatic and marine invertebrates. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Fast, sensitive and reliable multi-residue method for routine determination of 34 pesticides from various chemical groups in water samples by using dispersive liquid-liquid microextraction coupled with gas chromatography-mass spectrometry.

    PubMed

    Tankiewicz, Maciej; Biziuk, Marek

    2018-02-01

    A simple and efficient dispersive liquid-liquid microextraction technique (DLLME) was developed by using a mixture of two solvents: 40 μL of tetrachlorethylene (extraction solvent) and 1.0 mL of methanol (disperser solvent), which was rapidly injected with a syringe into 10 mL of water sample. Some important parameters affecting the extraction efficiency, such as type and volume of solvents, water sample volume, extraction time, temperature, pH adjustment and salt addition effect were investigated. Simultaneous determination of 34 commonly used pesticides was performed by using gas chromatography coupled with mass spectrometry (GC-MS). The procedure has been validated in order to obtain the highest efficiency at the lowest concentration levels of analytes to fulfill the requirements of regulations on maximum residue limits. Under the optimum conditions, the linearity range was within 0.0096-100 μg L -1 . The limits of detection (LODs) of the developed DLLME-GC-MS methodology for all investigated pesticides were in the range of 0.0032 (endrin)-0.0174 (diazinon) μg L -1 and limits of quantification (LOQs) from 0.0096 to 0.052 μg L -1 . At lower concentration of 1 μg L -1 for each pesticide, recoveries ranged between 84% (tebufenpyrad) and 108% (deltamethrin) with relative standard deviations (RSDs) (n = 7) from 1.1% (metconazole) to 11% (parathion-mehtyl). This methodology was successfully applied to check contamination of environmental samples. The procedure has proved to be selective, sensitive and precise for the simultaneous determination of various pesticides. The optimized analytical method is very simple and rapid (less than 5 min). Graphical abstract Analytical procedure for testing water samples consists of dispersive liquid-liquid microextraction (DLLME) and gas chromatography coupled with mass spectrometry (GC-MS).

  5. Multiresidue screening of endocrine-disrupting chemicals and pharmaceuticals in aqueous samples by multi-stir bar sorptive extraction-single desorption-capillary gas chromatography/mass spectrometry.

    PubMed

    Van Hoeck, Els; Canale, Francesca; Cordero, Chiara; Compernolle, Sien; Bicchi, Carlo; Sandra, Pat

    2009-02-01

    A multiresidue method for screening endocrine-disrupting chemicals (EDCs) and pharmaceuticals in aqueous samples is presented. Four 10-mL aliquots of water were taken for stir bar sorptive extraction (SBSE) and they were treated in the following way. In sample one, in situ derivatization was performed with acetic acid anhydride to improve the extraction efficiencies and chromatographic analysis of phenolic compounds. For the same reasons, aliquot two was treated with ethyl chloroformate to improve amine and acid extraction and analysis, and aliquot three with tetraethylborate to enhance organotin compound extraction and analysis. Methanol was added to sample four to stop adsorption of apolar solutes on the wall. After SBSE, the four stir bars, together with a plug of glass wool impregnated with bis(trimethylylsilyl)trifluoroacetamide (BSTFA) to derivatize hydroxyl functionalities, were introduced into the same thermal desorption tube, heat-desorbed, and analyzed simultaneously by capillary GC/MS. The figures of merit of the method were evaluated with an EDC model mixture. In scan-mode MS, the limits of detection (LODs) were in the range 1-500 ng/L, while the LODs dropped by a factor of 50-100 when ion monitoring MS was applied to the targets. The performance of the method was illustrated by analysing some real-world water samples.

  6. Critical evaluation and comparison of enrichment efficiency of multi-walled carbon nanotubes, C18 silica and activated carbon towards some pesticides from environmental waters.

    PubMed

    El-Sheikh, Amjad H; Sweileh, Jamal A; Al-Degs, Yahya S; Insisi, Ahmad A; Al-Rabady, Nancy

    2008-02-15

    In this work, optimization of multi-residue solid phase extraction (SPE) procedures coupled with high-performance liquid chromatography for the determination of Propoxur, Atrazine and Methidathion from environmental waters is reported. Three different sorbents were used in this work: multi-walled carbon nanotubes (MWCNTs), C18 silica and activated carbon (AC). The three optimized SPE procedures were compared in terms of analytical performance, application to environmental waters, cartridge re-use, adsorption capacity and cost of adsorbent. Although the adsorption capacity of MWCNT was larger than AC and C18, however, the analytical performance of AC could be made close to the other sorbents by appropriate optimization of the SPE procedures. A sample of AC was then oxidized with various oxidizing agents to show that ACs of various surface properties has different enrichment efficiencies. Thus researchers are advised to try AC of various surface properties in SPE of pollutants prior to using expensive sorbents (such as MWCNT and C18 silica).

  7. Matrix-effect free multi-residue analysis of veterinary drugs in food samples of animal origin by nanoflow liquid chromatography high resolution mass spectrometry.

    PubMed

    Alcántara-Durán, Jaime; Moreno-González, David; Gilbert-López, Bienvenida; Molina-Díaz, Antonio; García-Reyes, Juan F

    2018-04-15

    In this work, a sensitive method based on nanoflow liquid chromatography high-resolution mass spectrometry has been developed for the multiresidue determination of veterinary drugs residues in honey, veal muscle, egg and milk. Salting-out supported liquid extraction was employed as sample treatment for milk, veal muscle and egg, while a modified QuEChERS procedure was used in honey. The enhancement of sensitivity provided by the nanoflow LC system also allowed the implementation of high dilution factors as high as 100:1. For all matrices tested, matrix effects were negligible starting from a dilution factor of 100, enabling, thus, the use of external standard calibration instead of matrix-matched calibration of each sample, and the subsequent increase of laboratory throughput. At spiked levels as low as 0.1 or 1 µg kg -1 before the 1:100 dilution, the obtained signals were still significantly higher than the instrumental limit of quantitation (S/N 10). Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Multiresidue method for the determination of 77 pesticides in wine using QuEChERS sample preparation and gas chromatography with mass spectrometry.

    PubMed

    Jiang, Y; Li, X; Xu, J; Pan, C; Zhang, J; Niu, W

    2009-06-01

    A method based on a QuEChERS (quick, easy, cheap, effective, rugged, safe) sample preparation method and gas chromatography with mass spectrometric detection by selected ion monitoring (GC/MS-SIM) was developed for simultaneous determination of 77 pesticide residues in wine. An extraction of 10 ml of sample with acetonitrile followed by liquid-liquid partition formed by the addition of 4 g MgSO(4) and 3 g NaCl was applied in the sample preparation. The clean-up was carried out by applying dispersive solid-phase with 150 mg MgSO(4) as well as 50 mg primary secondary amine (PSA). One quantitation ion and at least two identification ions were selected in the analytical method for each pesticide compound by GC/MS. The recovery data were obtained by spiking blank samples at two concentration levels (0.05 and 0.2 mg l(-1)). The recoveries of all pesticides were in the range 70-110%, with intra-day precision of less than 15%, and the inter-day precision of less than 22% and 15% for 0.05 and 0.2 mg l(-1) fortification levels, respectively. Linearity was between 0.02 and 2 mg l(-1) with determination coefficients (R(2)) greater than 0.98 for all compounds. The limits of quantification (LOQs) for the 77 pesticides ranged from 0.003 to 0.05 mg l(-1). This method was applied for routine analysis in market products.

  9. Multiresidue method for N-methyl carbamates and metabolite pesticide residues at the parts-per-billion level in selected representative commodities of fruit and vegetable crop groups.

    PubMed

    Podhorniak, Lynda V; Schenck, Frank J; Krynitsky, Alexander; Griffith, Francis

    2004-01-01

    A reversed-phase liquid chromatographic method with both fluorescence and mass spectrometric detection is presented for the determination of 13 parent N-methyl carbamate pesticides and their metabolites, as well as piperonyl butoxide, for a total of 24 compounds in selected fruits and vegetables. The commodities chosen were of special concern to the U.S. Environmental Protection Agency (EPA) because they had the least amount of monitoring data for dietary exposure estimates used in risk assessment. The method is based on a judicious selection of procedures from U.S. Food and Drug Administration sources such as the Pesticide Analytical Manual (Volume I), and Laboratory Information Bulletins, plus additional material from the chemical literature combined in a manner to recover the N-methyl carbamates and their metabolites at the 1 microg/kg or 1 part-per-billion level. The method uses an acetone extraction, followed by an aminopropyl solid-phase extraction cleanup. Determination of residues is by RP-LC, in which the liquid chromatograph is interfaced with either a fluorescence or a mass spectrometric detector. The method is designed so that a set of 6 samples can be prepared in 1 working day for overnight instrumental analysis. Recovery data are presented from analyses of selected commodities in some of EPA's fruit and vegetable crop groupings. A table listing relative retention times is presented for the N-methyl carbamates and their metabolites.

  10. Gas chromatography with pulsed flame photometric detection multiresidue method for organophosphate pesticide and metabolite residues at the parts-per-billion level in representatives commodities of fruits and vegetable crop groups.

    PubMed

    Podhorniak, L V; Negron, J F; Griffith, F D

    2001-01-01

    A gas chromatographic method with a pulsed flame photometric detector (P-FPD) is presented for the analysis of 28 parent organophosphate (OP) pesticides and their OP metabolites. A total of 57 organophosphates were analyzed in 10 representative fruit and vegetable crop groups. The method is based on a judicious selection of known procedures from FDA sources such as the Pesticide Analytical Manual and Laboratory Information Bulletins, combined in a manner to recover the OPs and their metabolite(s) at the part-per-billion (ppb) level. The method uses an acetone extraction with either miniaturized Hydromatrix column partitioning or alternately a miniaturized methylene dichloride liquid-liquid partitioning, followed by solid-phase extraction (SPE) cleanup with graphitized carbon black (GCB) and PSA cartridges. Determination of residues is by programmed temperature capillary column gas chromatography fitted with a P-FPD set in the phosphorus mode. The method is designed so that a set of samples can be prepared in 1 working day for overnight instrumental analysis. The recovery data indicates that a daily column-cutting procedure used in combination with the SPE extract cleanup effectively reduces matrix enhancement at the ppb level for many organophosphates. The OPs most susceptible to elevated recoveries around or greater than 150%, based on peak area calculations, were trichlorfon, phosmet, and the metabolites of dimethoate, fenamiphos, fenthion, and phorate.

  11. An On-Line Solid Phase Extraction-Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Perfluoroalkyl Acids in Drinking and Surface Waters

    PubMed Central

    Mazzoni, Michela; Rusconi, Marianna; Valsecchi, Sara; Martins, Claudia P. B.; Polesello, Stefano

    2015-01-01

    An UHPLC-MS/MS multiresidue method based on an on-line solid phase extraction (SPE) procedure was developed for the simultaneous determination of 9 perfluorinated carboxylates (from 4 to 12 carbon atoms) and 3 perfluorinated sulphonates (from 4 to 8 carbon atoms). This work proposes using an on-line solid phase extraction before chromatographic separation and analysis to replace traditional methods of off-line SPE before direct injection to LC-MS/MS. Manual sample preparation was reduced to sample centrifugation and acidification, thus eliminating several procedural errors and significantly reducing time-consuming and costs. Ionization suppression between target perfluorinated analytes and their coeluting SIL-IS were detected for homologues with a number of carbon atoms less than 9, but the quantitation was not affected. Total matrix effect corrected by SIL-IS, inclusive of extraction efficacy, and of ionization efficiency, ranged between −34 and +39%. The percentage of recoveries, between 76 and 134%, calculated in different matrices (tap water and rivers impacted by different pollutions) was generally satisfactory. LODs and LOQs of this on-line SPE method, which also incorporate recovery losses, ranged from 0.2 to 5.0 ng/L and from 1 to 20 ng/L, respectively. Validated on-line SPE-LC/MS/MS method has been applied in a wide survey for the determination of perfluoroalkyl acids in Italian surface and ground waters. PMID:25834752

  12. Validation of a multi-residue method for the determination of several antibiotic groups in honey by LC-MS/MS.

    PubMed

    Bohm, Detlef A; Stachel, Carolin S; Gowik, Petra

    2012-07-01

    The presented multi-method was developed for the confirmation of 37 antibiotic substances from the six antibiotic groups: macrolides, lincosamides, quinolones, tetracyclines, pleuromutilines and diamino-pyrimidine derivatives. All substances were analysed simultaneously in a single analytical run with the same procedure, including an extraction with buffer, a clean-up by solid-phase extraction, and the measurement by liquid chromatography tandem mass spectrometry in ESI+ mode. The method was validated on the basis of an in-house validation concept with factorial design by combination of seven factors to check the robustness in a concentration range of 5-50 μg kg(-1). The honeys used were of different types with regard to colour and origin. The values calculated for the validation parameters-decision limit CCα (range, 7.5-12.9 μg kg(-1)), detection capability CCβ (range, 9.4-19.9 μg kg(-1)), within-laboratory reproducibility RSD(wR) (<20% except for tulathromycin with 23.5% and tylvalosin with 21.4 %), repeatability RSD(r) (<20% except for tylvalosin with 21.1%), and recovery (range, 92-106%)-were acceptable and in agreement with the criteria of Commission Decision 2002/657/EC. The validation results showed that the method was applicable for the residue analysis of antibiotics in honey to substances with and without recommended concentrations, although some changes had been tested during validation to determine the robustness of the method.

  13. Dispersive solid-phase extraction followed by vortex-assisted dispersive liquid-liquid microextraction based on the solidification of a floating organic droplet for the determination of benzoylurea insecticides in soil and sewage sludge.

    PubMed

    Peng, Guilong; He, Qiang; Mmereki, Daniel; Lu, Ying; Zhong, Zhihui; Liu, Hanyang; Pan, Weiliang; Zhou, Guangming; Chen, Junhua

    2016-04-01

    A novel dispersive solid-phase extraction combined with vortex-assisted dispersive liquid-liquid microextraction based on solidification of floating organic droplet was developed for the determination of eight benzoylurea insecticides in soil and sewage sludge samples before high-performance liquid chromatography with ultraviolet detection. The analytes were first extracted from the soil and sludge samples into acetone under optimized pretreatment conditions. Clean-up of the extract was conducted by dispersive solid-phase extraction using activated carbon as the sorbent. The vortex-assisted dispersive liquid-liquid microextraction based on solidification of floating organic droplet procedure was performed by using 1-undecanol with lower density than water as the extraction solvent, and the acetone contained in the solution also acted as dispersive solvent. Under the optimum conditions, the linearity of the method was in the range 2-500 ng/g with correlation coefficients (r) of 0.9993-0.9999. The limits of detection were in the range of 0.08-0.56 ng/g. The relative standard deviations varied from 2.16 to 6.26% (n = 5). The enrichment factors ranged from 104 to 118. The extraction recoveries ranged from 81.05 to 97.82% for all of the analytes. The good performance has demonstrated that the proposed methodology has a strong potential for application in the multiresidue analysis of complex matrices. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Multiresidue method for the determination of 227 pesticides in hot pepper (Capsicum annuum L.) by liquid chromatography with tandem mass spectrometry.

    PubMed

    Zhu, Yong-Zhe; Zhao, Mei-Ai; Nan Feng, Ya; Han Kim, Jeong

    2014-10-01

    A high-throughput, rapid, and efficient modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method with a simple cleanup procedure has been developed for simultaneously determining 227 pesticides in pepper samples by liquid chromatography with tandem mass spectrometry (running time: 10 min). Pesticide residues were extracted/partitioned with an acetonitrile/DisQuE QuEChERS pouch, and the resulting samples were cleaned up with different methods: dispersive solid-phase extraction with primary secondary amines or multiwalled carbon nanotubes and graphitized carbon solid mini cartridge column. The results indicated that multiwalled carbon nanotubes dispersive sorbents achieved the best recoveries and had less matrix interference. The numbers of pesticides with a recovery in the range of 70-120% were 199 at a spiked level of 40 μg/kg. The correlation coefficients (r(2)) for 227 pesticides were above 0.99, while the limits of quantitation of pesticides in pepper samples ranged from 0.13 to 13.51 μg/kg (S/N = 10), and the limits of detection ranged from 0.04 to 4.05 μg/kg (S/N = 3). The relative standard deviations of approximately 197 pesticides were below 20% at spiked levels of 40 μg/kg. Based on these results, the proposed method was chosen as the most suitable cleanup procedure for the determination of multiresidue pesticides in pepper samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Validation of a new screening, determinative, and confirmatory multi-residue method for nitroimidazoles and their hydroxy metabolites in turkey muscle tissue by liquid chromatography-tandem mass spectrometry.

    PubMed

    Boison, Joe O; Asea, Philip A; Matus, Johanna L

    2012-08-01

    A new and sensitive multi-residue method (MRM) with detection by LC-MS/MS was developed and validated for the screening, determination, and confirmation of residues of 7 nitroimidazoles and 3 of their metabolites in turkey muscle tissues at concentrations ≥ 0.05 ng/g. The compounds were extracted into a solvent with an alkali salt. Sample clean-up and concentration was then done by solid-phase extraction (SPE) and the compounds were quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The characteristic parameters including repeatability, selectivity, ruggedness, stability, level of quantification, and level of confirmation for the new method were determined. Method validation was achieved by independent verification of the parameters measured during method characterization. The seven nitroimidazoles included are metronidazole (MTZ), ronidazole (RNZ), dimetridazole (DMZ), tinidazole (TNZ), ornidazole (ONZ), ipronidazole (IPR), and carnidazole (CNZ). It was discovered during the single laboratory validation of the method that five of the seven nitroimidazoles (i.e. metronidazole, dimetridazole, tinidazole, ornidazole and ipronidazole) and the 3 metabolites (1-(2-hydroxyethyl)-2-hydroxymethyl-5-nitroimidazole (MTZ-OH), 2-hydroxymethyl-1-methyl-5-nitroimidazole (HMMNI, the common metabolite of ronidazole and dimetridazole), and 1-methyl-2-(2'-hydroxyisopropyl)-5-nitroimidazole (IPR-OH) included in this study could be detected, confirmed, and quantified accurately whereas RNZ and CNZ could only be detected and confirmed but not accurately quantified. © Her Majesty the Queen in Right of Canada as Represented by the Minister of Agriculture and Agri-food Canada 2012.

  16. Quantitative analysis of antibiotics in aquifer sediments by liquid chromatography coupled to high resolution mass spectrometry.

    PubMed

    Tong, Lei; Liu, Hui; Xie, Cong; Li, Minjing

    2016-06-24

    A highly effective analytical method for multi-residue determination of antibiotics in aquifer sediments was first established in this study. Microwave-assisted solvent extraction (MASE) and solid-phase extraction were used for sample pre-concentration and purification, ultra-high performance liquid chromatography coupled to hybrid quadrupole-high resolution Orbitrap mass spectrometry (UHPLC-Q-Orbitrap) was applied for detection. For high resolution mass spectrometry (HRMS), the target compounds were tentatively identified by retention time and accurate mass which was measured with precursor ions in Target-SIM scan, and then confirmed by the monitoring of daughter ion fragments which were generated in dd-MS(2) scan. The results provided good mass accuracy with mass deviations below 2ppm (except norfloxacin with -2.3ppm) for quantitative analysis of the compounds by HRMS. Reasonable recoveries of all analytes were obtained more than 60% (except doxytetracycline) in fortification samples at concentrations higher than 10μgkg(-1). Relative standard deviations of repeatability and inter-day precision were below 21% and 11%. Limits of detection (LOD) ranged from 0.1 to 3.8μgkg(-1), whereas limits of quantification (LOQ) were established between 0.3-9.0μgkg(-1). The method was applied to analyze real aquifer sediment samples in different aquifer depth of 4.0, 7.5, 13.0 and 18.0m. Chlorotetracycline and ofloxacin were observed at relative high concentrations of 53 and 19μgkg(-1) respectively in 18.0m deepness. The exposure to low doses of these compounds in subsurface environment increases concerns on long-term ecological security of underground system. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Enantioselective simultaneous analysis of selected pharmaceuticals in environmental samples by ultrahigh performance supercritical fluid based chromatography tandem mass spectrometry.

    PubMed

    Camacho-Muñoz, Dolores; Kasprzyk-Hordern, Barbara; Thomas, Kevin V

    2016-08-31

    In order to assess the true impact of each single enantiomer of pharmacologically active compounds (PACs) in the environment, highly efficient, fast and sensitive analytical methods are needed. For the first time this paper focuses on the use of ultrahigh performance supercritical fluid based chromatography coupled to a triple quadrupole mass spectrometer to develop multi-residue enantioselective methods for chiral PACs in environmental matrices. This technique exploits the advantages of supercritical fluid chromatography, ultrahigh performance liquid chromatography and mass spectrometry. Two coated modified 2.5 μm-polysaccharide-based chiral stationary phases were investigated: an amylose tris-3,5-dimethylphenylcarbamate column and a cellulose tris-3-chloro-4-methylphenylcarbamate column. The effect of different chromatographic variables on chiral recognition is highlighted. This novel approach resulted in the baseline resolution of 13 enantiomers PACs (aminorex, carprofen, chloramphenicol, 3-N-dechloroethylifosfamide, flurbiprofen, 2-hydroxyibuprofen, ifosfamide, imazalil, naproxen, ofloxacin, omeprazole, praziquantel and tetramisole) and partial resolution of 2 enantiomers PACs (ibuprofen and indoprofen) under fast-gradient conditions (<10 min analysis time). The overall performance of the methods was satisfactory. The applicability of the methods was tested on influent and effluent wastewater samples. To the best of our knowledge, this is the first feasibility study on the simultaneous separation of chemically diverse chiral PACs in environmental matrices using ultrahigh performance supercritical fluid based chromatography coupled with tandem mass spectrometry. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Green and simple analytical method to determine benzimidazoles in milk samples by using salting-out assisted liquid-liquid extraction and capillary liquid chromatography.

    PubMed

    Tejada-Casado, Carmen; Del Olmo-Iruela, Monsalud; García-Campaña, Ana M; Lara, Francisco J

    2018-08-01

    A green and simple multiresidue method using capillary liquid chromatography (CLC) with UV-diode array detection (DAD) has been developed for the determination of sixteen benzimidazoles (BZs) and its metabolites in milk samples. The separation was achieved in <32 min, using a Zorbax XDB-C18 column (150 mm × 0.5 mm I.D, 5 μm), with a mobile phase consisting of 50 mM ammonium acetate (solvent A) and a mixture of acetonitrile/methanol (1:1 v/v) (solvent B), at a flow rate of 9 μL min -1 . The temperature of the column was 20 °C and 6 μL of sample were injected. In spite of the complexity of milk samples, an effective, simple and fast sample preparation method called salting out-assisted liquid-liquid extraction (SALLE) was developed for the analysis of these compounds in cow milk samples. To obtain satisfactory extraction efficiencies for the studied analytes, several parameters affecting the SALLE procedure were optimized including the amount of sample, type and volume of the extraction solvent, and the nature and amount of the salt. Good linearity was obtained (R 2  > 0.9985 for all BZs) with limits of detection (LOD) between 1.0 and 2.8 μg kg -1 . Relative standard deviations of repeatability and intermediate precision were below 1.6 and 14.2%, respectively. Satisfactory recoveries between 79.1 and 99.6% were also obtained for three types of milk samples (cow, sheep and goat). The advantages of a miniaturized technique such as CLC in terms of better efficiencies and reduced solvent consumption, combined with the simplicity of the SALLE procedure, make this method a useful alternative for the monitoring of these residues at trace level. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Multiresidue Method for Quantification of Sulfonamides and Trimethoprim in Tilapia Fillet by Liquid Chromatography Coupled to Quadrupole Time-of-Flight Mass Spectrometry Using QuEChERS for Sample Preparation.

    PubMed

    Nunes, Kátia S D; Assalin, Márcia R; Vallim, José H; Jonsson, Claudio M; Queiroz, Sonia C N; Reyes, Felix G R

    2018-01-01

    A multiresidue method for detecting and quantifying sulfonamides (sulfapyridine, sulfamerazine, sulfathiazole, sulfamethazine, sulfadimethoxine, sulfamethoxazole, and sulfamethoxypyridazine) and trimethoprim in tilapia fillet ( Oreochromis niloticus ) using liquid chromatography coupled to mass spectrometry was developed and validated. The sample preparation was optimized using the QuEChERS approach. The chromatographic separation was performed using a C18 column and 0.1% formic acid in water and acetonitrile as the mobile phase in the isocratic elution mode. Method validation was performed based on the Commission Decision 2002/657/EC and Brazilian guideline. The validation parameters evaluated were linearity ( r  ≥ 0.99); limits of detection (LOD) and quantification (LOQ), 1 ng·g -1 and 5 ng·g -1 , respectively; intraday and interdays precision (CV lower than 19.4%). The decision limit (CC α 102.6-120.0 ng·g -1 and 70 ng·g -1 for sulfonamides and trimethoprim, respectively) and detection capability (CC β 111.7-140.1 ng·g -1 and 89.9 ng·g -1 for sulfonamides and trimethoprim, respectively) were determined. Analyses of tilapia fillet samples from fish exposed to sulfamethazine through feed (incurred samples) were conducted in order to evaluate the method. This new method was demonstrated to be fast, sensitive, and suitable for monitoring sulfonamides and trimethoprim in tilapia fillet in health surveillance programs, as well as to be used in pharmacokinetics and residue depletion studies.

  20. Multiresidue Method for Quantification of Sulfonamides and Trimethoprim in Tilapia Fillet by Liquid Chromatography Coupled to Quadrupole Time-of-Flight Mass Spectrometry Using QuEChERS for Sample Preparation

    PubMed Central

    Nunes, Kátia S. D.; Assalin, Márcia R.; Vallim, José H.; Jonsson, Claudio M.; Queiroz, Sonia C. N.

    2018-01-01

    A multiresidue method for detecting and quantifying sulfonamides (sulfapyridine, sulfamerazine, sulfathiazole, sulfamethazine, sulfadimethoxine, sulfamethoxazole, and sulfamethoxypyridazine) and trimethoprim in tilapia fillet (Oreochromis niloticus) using liquid chromatography coupled to mass spectrometry was developed and validated. The sample preparation was optimized using the QuEChERS approach. The chromatographic separation was performed using a C18 column and 0.1% formic acid in water and acetonitrile as the mobile phase in the isocratic elution mode. Method validation was performed based on the Commission Decision 2002/657/EC and Brazilian guideline. The validation parameters evaluated were linearity (r ≥ 0.99); limits of detection (LOD) and quantification (LOQ), 1 ng·g−1 and 5 ng·g−1, respectively; intraday and interdays precision (CV lower than 19.4%). The decision limit (CCα 102.6–120.0 ng·g−1 and 70 ng·g−1 for sulfonamides and trimethoprim, respectively) and detection capability (CCβ 111.7–140.1 ng·g−1 and 89.9 ng·g−1 for sulfonamides and trimethoprim, respectively) were determined. Analyses of tilapia fillet samples from fish exposed to sulfamethazine through feed (incurred samples) were conducted in order to evaluate the method. This new method was demonstrated to be fast, sensitive, and suitable for monitoring sulfonamides and trimethoprim in tilapia fillet in health surveillance programs, as well as to be used in pharmacokinetics and residue depletion studies. PMID:29686929

  1. Liquid chromatography-tandem mass spectrometry multiresidue method for the analysis of quaternary ammonium compounds in cheese and milk products: Development and validation using the total error approach.

    PubMed

    Slimani, Kahina; Féret, Aurélie; Pirotais, Yvette; Maris, Pierre; Abjean, Jean-Pierre; Hurtaud-Pessel, Dominique

    2017-09-29

    Quaternary ammonium compounds (QACs) are both cationic surfactants and biocidal substances widely used as disinfectants in the food industry. A sensitive and reliable method for the analysis of benzalkonium chlorides (BACs) and dialkyldimethylammonium chlorides (DDACs) has been developed that enables the simultaneous quantitative determination of ten quaternary ammonium residues in dairy products below the provisional maximum residue level (MRL), set at 0.1mgkg -1 . To the best of our knowledge, this method could be the one applicable to milk and to three major processed milk products selected, namely processed or hard pressed cheeses, and whole milk powder. The method comprises solvent extraction using a mixture of acetonitrile and ethyl acetate, without any further clean-up. Analyses were performed by liquid chromatography coupled with electrospray tandem mass spectrometry detection (LC-ESI-MS/MS) operating in positive mode. A C18 analytical column was used for chromatographic separation, with a mobile phase composed of acetonitrile and water both containing 0.3% formic acid; and methanol in the gradient mode. Five deuterated internal standards were added to obtain the most accurate quantification. Extraction recoveries were satisfactory and no matrix effects were observed. The method was validated using the total error approach in accordance with the NF V03-110 standard in order to characterize the trueness, repeatability, intermediate precision and analytical limits within the range of 5-150μgkg -1 for all matrices. These performance criteria, calculated by e.noval ® 3.0 software, were satisfactory and in full accordance with the proposed provisional MRL and with the recommendations in the European Union SANTE/11945/2015 regulatory guidelines. The limit of detection (LOD) was low (<1.9μgkg -1 ) and the limit of quantification (LOQ) ranged from 5μgkg -1 to 35μgkg -1 for all matrices depending on the analytes. The validation results proved that the method is suitable for quantifying quaternary ammoniums in foodstuffs from dairy industries at residue levels, and could be used for biocide residues monitoring plans and to measure the exposition consumer to biocides products. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Multi-residue analysis of 26 organochlorine pesticides in Alpinia oxyphylla by GC-ECD after solid phase extraction and acid cleanup.

    PubMed

    Zhao, Xiangsheng; Zhou, Yakui; Kong, Weijun; Gong, Bao; Chen, Deli; Wei, Jianhe; Yang, Meihua

    2016-04-01

    A simple and effective multi-residue method was developed and validated for the analysis of 26 organochlorine pesticide residues in Alpinia oxyphylla by a gas chromatography with an electron capture detector (GC-ECD). The target pesticides were extracted by sonication and cleaned up with florisil solid phase extraction and sulphuric acid. Some crucial parameters, including extraction solvent and time, sorbent type, elute solvent and concentration of sulphuric acid were optimized to improve the performance of sample preparation procedure. The optimized method gave high sensitivity with detection limit ranging from 0.1 to 2.0μg/kg. Matrix-matched calibration was employed for the quantification, and a wide linear range (from 1.0 to 1000μg/kg) with r(2) values ranging from 0.9971 to 0.9998 was obtained. For the majority of the tested pesticides, the average recoveries were in acceptable range (between 70% and 110%) with relative standard deviation values below 15.0%. Matrix effect was evaluated for target compounds through the study of ratio of peak area obtained in the solvent and blank matrix. The proposed method was applied to simultaneously analyze 26 pesticides in 55 batches of Alpinia oxyphylla samples. 3 samples were found to be positive with four pesticides (α-BHC, quintozene, trans-chlordane and op'-DDD), which were confirmed by gas chromatography-mass spectrometry (GC-MS) in selective ion monitoring (SIM) mode. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Quantitative targeted and retrospective data analysis of relevant pesticides, antibiotics and mycotoxins in bakery products by liquid chromatography-single-stage Orbitrap mass spectrometry.

    PubMed

    De Dominicis, Emiliano; Commissati, Italo; Gritti, Elisa; Catellani, Dante; Suman, Michele

    2015-01-01

    In addition to 'traditional' multi-residue and multi-contaminant multiple reaction monitoring (MRM) mass spectrometric techniques devoted to quantifying a list of targeted compounds, the global food industry requires non-targeted methods capable of detecting other possible potentially hazardous compounds. Ultra-high-performance liquid chromatography combined with a single-stage Orbitrap high-resolution mass spectrometer (UHPLC-HRMS Exactive™-Orbitrap Technology) was successfully exploited for the complete selective and quantitative determination of 33 target compounds within three major cross categories (pesticides, antibiotics and mycotoxins) in bakery matrices (specifically milk, wheat flour and mini-cakes). Resolution was set at 50 000 full width at half maximum (FWHM) to achieve the right compromise between an adequate scan speed and selectivity, allowing for the limitations related to the necessary generic sample preparation approach. An exact mass with tolerance of 5 ppm and minimum peak threshold of 10 000 units were fixed as the main identification conditions, including retention time and isotopic pattern as additional criteria devoted to greatly reducing the risk of false-positive findings. The full validation for all the target analytes was performed: linearity, intermediate repeatability and recovery (28 analytes within 70-120%) were positively assessed; furthermore, limits of quantification between 5 and 100 µg kg(-1) (with most of the analytes having a limit of detection below 6 µg kg(-1)) indicate good performance, which is compatible with almost all the regulatory needs. Naturally contaminated and fortified mini-cakes, prepared through combined use of industrial and pilot plant production lines, were analysed at two different concentration levels, obtaining good overall quantitative results and providing preliminary indications of the potential of full-scan HRMS cluster analysis. The effectiveness of this analytical approach was also tested in terms of the formulation of hypotheses for the identification of other analytes not initially targeted which can have toxicological implications (e.g. 3-acetyl-deoxynivalenol and deoxynivalenol-3-glucoside), opening a window on retrospective investigation perspectives in food safety laboratories.

  4. A multi-residue method for characterization of endocrine disruptors in gaseous and particulate phases of ambient air

    NASA Astrophysics Data System (ADS)

    Alliot, Fabrice; Moreau-Guigon, Elodie; Bourges, Catherine; Desportes, Annie; Teil, Marie-Jeanne; Blanchard, Martine; Chevreuil, Marc

    2014-08-01

    A number of semi-volatile compounds occur in indoor air most of them being considered as potent endocrine disruptors and thus, exerting a possible impact upon health. To assess their concentration levels in indoor air, we developed and validated a method for sampling and multi-residue analysis of 58 compounds including phthalates, polycyclic aromatic hydrocarbons (PAHs), polybromodiphenylethers (PBDEs), polychlorobiphenyls (PCBs), parabens, bisphenol A (BPA) and tetrabromobisphenol A (TBBPA) in gaseous and particulate phases of air. We validated each step of procedures from extraction until analysis. Matrice spiking were performed at extraction, fractionation and purification stages. The more volatile compounds were analyzed with a gas chromatography system coupled with a mass spectrometer (GC/MS) or with a tandem mass spectrometer (GC/MS/MS). The less volatile compounds were analyzed with a liquid chromatography system coupled with a tandem mass spectrometer (LC/MS/MS). Labeled internal standard method was used ensuring high quantification accuracy. The instrumental detection limits were under 1 pg for all compounds and therefore, a limit of quantification averaging 1 pg m-3 for the gaseous and the particulate phases and a volume of 150 m3, except for phthalates, phenol compounds and BDE-209. Satisfactory recoveries were found except for phenol compounds. That method was successfully applied to several indoor air samples (office, apartment and day nursery) and most of the targeted compounds were quantified, mainly occurring in the gaseous phase. The most abundant were phthalates (up to 918 ng m-3 in total air), followed by PCBs > parabens > BPA > PAHs > PBDEs.

  5. Determination of residual carbamate, organophosphate, and phenyl urea pesticides in drinking and surface water by high-performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Hao, Chunyan; Nguyen, Bick; Zhiao, Xiaoming; Chen, Ernie; Yang, Paul

    2010-01-01

    Methods using SPE followed by HPLC/MS/MS analysis were developed and validated for the determination of 39 pesticides in different aquatic environmental matrixes. The target pesticides included 12 carbamates, 15 organophosphates, and 12 phenyl ureas, out of which 16 are regulated in North America. Method detection limits were in the low ng/L range using the U.S. Environmental Protection Agency's protocol and multiple reaction monitoring (MRM) data acquisition, meeting the regulatory needs in the United States, Canada, and European Union. Isotope-labeled compounds were used as injection internal standards, as well as method surrogates to improve the data quality. QC/QA data (e.g., method recovery and within-run and between-run method precision) derived from multiyear monitoring activities were used to demonstrate method ruggedness. The same QC/QA data also showed that the method exerted no obvious matrix effect on the target analytes. Parameters that affect method performance, such as preservatives, pH values, sample storage time, and sample extract storage time, were also studied in detail. Accredited by the Canadian Association for Laboratory Accreditation and licensed by the Ontario government for drinking water analysis, these methods have been applied to the analysis of drinking water, ground water, and surface water samples collected in the province of Ontario, Canada, to ensure the pristine nature of Ontario's aquatic environment. Using the scheduled MRM (sMRM) data acquisition algorithm, it was demonstrated that sMRM improved the S/N of extracted ion chromatograms by at least two- to six-fold and, therefore, enhanced the short- and long-term instrument precision, demonstrated the ability to offer high throughput multiresidue analysis, and allowed the use of two MRM transitions for each compound to achieve higher confidence for compound identification.

  6. Multi-residue determination of pharmaceutical and personal care products in vegetables.

    PubMed

    Wu, Xiaoqin; Conkle, Jeremy Landon; Gan, Jay

    2012-09-07

    Treated wastewater irrigation and biosolid amendment are increasingly practiced worldwide and contamination of plants, especially produces that may be consumed raw by humans, by pharmaceutical and personal care products (PPCPs), is an emerging concern. A sensitive method was developed for the simultaneous measurement of 19 frequently-occurring PPCPs in vegetables using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) for detection, combined with ultrasonic extraction and solid phase extraction (SPE) cleanup for sample preparation. Deuterated standards were used as surrogates to quantify corresponding analytes. The corrected recoveries ranged between 87.1 and 123.5% for iceberg lettuce, with intra- and inter-day variations less than 20%, and the method detection limits (MDLs) in the range of 0.04-3.0 ng g⁻¹ dry weight (dw). The corrected recoveries were equally good when the method was used on celery, tomato, carrot, broccoli, bell pepper and spinach. The method was further applied to examine uptake of PPCPs by iceberg lettuce and spinach grown in hydroponic solutions containing each PPCP at 500 ng L⁻¹. Twelve PPCPs were detected in lettuce leaves with concentrations from 0.2 to 28.7 ng g⁻¹ dw, while 11 PPCPs were detected in spinach leaves at 0.04-34.0 ng g⁻¹ dw. Given the diverse chemical structures of PPCPs considered in this study, this method may be used for screening PPCP residues in vegetables and other plants impacted by treated wastewater or biosolids, and to estimate potential human exposure via dietary uptake. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Glyphosate analysis using sensors and electromigration separation techniques as alternatives to gas or liquid chromatography.

    PubMed

    Gauglitz, Günter; Wimmer, Benedikt; Melzer, Tanja; Huhn, Carolin

    2018-01-01

    Since its introduction in 1974, the herbicide glyphosate has experienced a tremendous increase in use, with about one million tons used annually today. This review focuses on sensors and electromigration separation techniques as alternatives to chromatographic methods for the analysis of glyphosate and its metabolite aminomethyl phosphonic acid. Even with the large number of studies published, glyphosate analysis remains challenging. With its polar and depending on pH even ionic functional groups lacking a chromophore, it is difficult to analyze with chromatographic techniques. Its analysis is mostly achieved after derivatization. Its purification from food and environmental samples inevitably results incoextraction of ionic matrix components, with a further impact on analysis derivatization. Its purification from food and environmental samples inevitably results in coextraction of ionic matrix components, with a further impact on analysis and also derivatization reactions. Its ability to form chelates with metal cations is another obstacle for precise quantification. Lastly, the low limits of detection required by legislation have to be met. These challenges preclude glyphosate from being analyzed together with many other pesticides in common multiresidue (chromatographic) methods. For better monitoring of glyphosate in environmental and food samples, further fast and robust methods are required. In this review, analytical methods are summarized and discussed from the perspective of biosensors and various formats of electromigration separation techniques, including modes such as capillary electrophoresis and micellar electrokinetic chromatography, combined with various detection techniques. These methods are critically discussed with regard to matrix tolerance, limits of detection reached, and selectivity.

  8. A Simple and High-Throughput Analysis of Amatoxins and Phallotoxins in Human Plasma, Serum and Urine Using UPLC-MS/MS Combined with PRiME HLB μElution Platform

    PubMed Central

    Zhang, Shuo; Zhao, Yunfeng; Li, Haijiao; Zhou, Shuang; Chen, Dawei; Zhang, Yizhe; Yao, Qunmei; Sun, Chengye

    2016-01-01

    Amatoxins and phallotoxins are toxic cyclopeptides found in the genus Amanita and are among the predominant causes of fatal food poisoning in China. In the treatment of Amanita mushroom poisoning, an early and definite diagnosis is necessary for a successful outcome, which has prompted the development of protocols for the fast and confirmatory determination of amatoxins and phallotoxins in human biological fluids. For this purpose, a simple, rapid and sensitive multiresidue UPLC-MS/MS method for the simultaneous determination of α-amanitin, β-amanitin, γ-amanitin, phalloidin (PHD) and phallacidin (PCD) in human plasma, serum and urine was developed and validated. The diluted plasma, serum and urine samples were directly purified with a novel PRiME technique on a 96-well μElution plate platform, which allowed high-throughput sample processing and low reagent consumption. After purification, a UPLC-MS/MS analysis was performed using positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode. This method fulfilled the requirements of a validation test, with good results for the limit of detection (LOD), lower limit of quantification (LLOQ), accuracy, intra- and inter-assay precision, recovery and matrix effects. All of the analytes were confirmed and quantified in authentic plasma, serum and urine samples obtained from cases of poisoning using this method. Using the PRiME μElution technique for quantification reduces labor and time costs and represents a suitable method for routine toxicological and clinical emergency analysis. PMID:27153089

  9. Factors Affecting Transfer of Pyrethroid Residues from Herbal Teas to Infusion and Influence of Physicochemical Properties of Pesticides

    PubMed Central

    Xiao, Jin-Jing; Li, Yang; Fang, Qing-Kui; Shi, Yan-Hong; Liao, Min; Wu, Xiang-Wei; Hua, Ri-Mao

    2017-01-01

    The transfer of pesticide residues from herbal teas to their infusion is a subject of particular interest. In this study, a multi-residue analytical method for the determination of pyrethroids (fenpropathrin, beta-cypermethrin, lambda-cyhalothrin, and fenvalerate) in honeysuckle, chrysanthemum, wolfberry, and licorice and their infusion samples was validated. The transfer of pyrethroid residues from tea to infusion was investigated at different water temperatures, tea/water ratios, and infusion intervals/times. The results show that low amounts (0–6.70%) of pyrethroids were transferred under the different tea brewing conditions examined, indicating that the infusion process reduced the pyrethroid content in the extracted liquid by over 90%. Similar results were obtained for the different tea varieties, and pesticides with high water solubility and low octanol–water partition coefficients (log Kow) exhibited high transfer rates. Moreover, the estimated values of the exposure risk to the pyrethroids were in the range of 0.0022–0.33, indicating that the daily intake of the four pyrethroid residues from herbal tea can be regarded as safe. The present results can support the identification of suitable tea brewing conditions for significantly reducing the pesticide residue levels in the infusion. PMID:28973970

  10. Development and evaluation of a gas chromatographic method for the determination of triazine herbicides in natural water samples

    USGS Publications Warehouse

    Steinheimer, T.R.; Brooks, M.G.

    1984-01-01

    A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0.1 ??g/L in a 1-litre sample. Three different natural water samples were used for error analysis via evaluation of recovery efficiencies and estimation of overall method precision. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0. 1 mu g/L in a 1-litre sample. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.

  11. Evaluation of a Microbiological Multi-Residue System on the detection of antibacterial substances in ewe milk.

    PubMed

    Althaus, Rafael; Berruga, Maria Isabel; Montero, Ana; Roca, Marta; Molina, Maria Pilar

    2009-01-19

    To protect both, public health and the dairy industry, from the presence of antibiotic residues in milk, control programmes have been established, which include the needed screening tests. This work focuses on the application of a Microbiological Multi-Residue System in ewe milk, a method based on the use of six different plates, each seeded with one of the following bacteria: Geobacillus stearothermophilus var. calidolactis (beta-lactams), Bacillus subtilis at pH 8.0 (aminoglycosides), Kocuria rhizophila (macrolides), Escherichia coli (quinolones), B. cereus (tetracyclines) and B. subtilis at pH 7.0 (sulphonamides), respectively. Twenty-three antimicrobial substances were analysed and a logistic regression was established for each substance assayed to relate the antibiotic concentration and the zone of microbial growth inhibition. Great linearity in the response was observed (regression coefficients of over 0.97). This fact suggests the possibility of establishing a decision level of antibiotic concentrations near to the Maximum Residue Limits (MRL). Zones of inhibition were suggested as proposed action levels for the different antimicrobial groups (diameters of inhibition of 18 mm for the aminoglycoside, beta-lactam and sulphonamide plates; 19 mm for the tetracycline plate, 21 mm for the macrolide plate, and 24 mm for the quinolone plate). Specificity and cross-reactivity were also assayed.

  12. Multi-residue determination of 10 selected new psychoactive substances in wastewater samples by liquid chromatography-tandem mass spectrometry.

    PubMed

    Borova, Viola L; Gago-Ferrero, Pablo; Pistos, Constantinos; Thomaidis, Nikolaos S

    2015-11-01

    New psychoactive substances (NPSs) have become increasingly popular in recent years. The analysis of these substances in influent wastewater (IWW) can be used to track their use in communities. In addition, an evaluation of the amount of NPSs released to the aquatic environment can be performed through the analysis of effluent wastewater (EWW). This study presents the development, validation and application of an analytical methodology, based on solid phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS), for the determination of 10 NPSs in IWW and EWW. Synthetic cannabinoids, cathinones, piperazines and pyrrolidophenones are included among the target analytes. To the authors' knowledge, it is the first time that eight out of these substances (4'-methylpyrrolidinobutyrophenone (MPPP), a-pyrrolidinopentiophenone (a-PVP), 2-[(1S,3R)-3-hydroxycyclohexyl]-5-(2-methyl-2-octanyl) phenol (CP47,497), (1-naphthyl(1-pentyl-1H-indol-3-yl) methanone (JWH-018), (1-butyl-1H-indol-3-yl)(1-naphthyl) methanone (JWH-073), (4-ethyl-1-naphthyl)(1-pentyl-1H-indol-3-yl) methanone (JWH-210), (4-methyl-1-naphthyl) (1-pentyl-1H-indol-3-yl) methanone (JWH-122) and 2-(2-methoxyphenyl)-1-(1-pentyl-1H-indol-3-yl) ethanone (JWH-250)) are investigated in wastewater. The optimized conditions for the analysis of this set of compounds included a SPE clean-up step using a polymeric sorbent and the use of a pentafluorophenyl (PFP) chromatographic column. Despite the broad range of physicochemical properties of the analytes the method allowed acceptable absolute recoveries (40-109%) for all the studied compounds at different levels of concentration. Low method limits of detection (MLODs) were achieved, ranging between 0.3 and 10 ng/L except for BZP and CP47,497 (20 and 23 ng/L, respectively), allowing a reliable and accurate quantification of the analytes. The method was successfully applied to the analysis of IWW and EWW samples from five wastewater treatment plants (WWTPs) located in Santorini Island (a highly touristic resort in Greece). Four out of 10 compounds (a-PVP, CP47,497, JWH-122 and JWH-210) were detected at least in one sample, being the first evidence of their presence in wastewater. CP47,497 was the most ubiquitous and abundant compound, showing concentrations up to 634 ng/L in some cases. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Quantitative analysis of veterinary drugs in bovine muscle and milk by liquid chromatography quadrupole time-of-flight mass spectrometry.

    PubMed

    Saito-Shida, Shizuka; Sakai, Takatoshi; Nemoto, Satoru; Akiyama, Hiroshi

    2017-07-01

    A simple and reliable multiresidue method for quantitative determination of veterinary drugs in bovine muscle and milk using liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) was developed. Critical MS parameters such as capillary voltage, cone voltage, collision energy, desolvation gas temperature and extraction mass window were carefully optimised to obtain the best possible sensitivity. Analytical samples were prepared using extraction with acetonitrile and hexane in the presence of anhydrous sodium sulphate and acetic acid, followed by ODS cartridge clean-up. The developed method was validated for 82 veterinary drugs in bovine muscle and milk at spike levels of 0.01 and 0.1 mg kg - 1 . With the exception of cefoperazone and phenoxymethylpenicillin, all these compounds exhibited sufficient signal intensity at 0.01 μg ml -1 (equivalent to 0.01 mg kg - 1 ), indicating the high sensitivity of the developed method. For most targets, the determined accuracies were within 70-120%, with repeatability and reproducibility being below 20% at both levels. Except for sulfathiazole in bovine muscle, no interfering peaks at target compound retention times were detected in the blank extract, indicating that the developed method is highly selective. The absence of sulfathiazole in bovine muscle was confirmed by simultaneous acquisition at low and high collision energies to afford exact masses of molecular adduct and fragment ions. Satisfactory linearity was observed for all compounds, with matrix effects being negligible for most targets in bovine muscle and milk at both spike levels. Overall, the results suggest that the developed LC-QTOF-MS method is suitable for routine regulatory-purpose analysis of veterinary drugs in bovine muscle and milk.

  14. A multiresidue method for the determination of selected endocrine disrupting chemicals in human breast milk based on a simple extraction procedure.

    PubMed

    Rodríguez-Gómez, R; Jiménez-Díaz, I; Zafra-Gómez, A; Ballesteros, O; Navalón, A

    2014-12-01

    In recent decades, in parallel to industrial development, a large amount of new chemicals have emerged that are able to produce disorders in human endocrine system. These groups of substances, so-called endocrine disrupting chemicals (EDCs), include many families of compounds, such as parabens, benzophenone-UV filters and bisphenols. Given the demonstrated biological activity of those compounds, it is necessary to develop new analytical procedures to evaluate the exposure with the final objective of establishing, in an accurate way, relationships between EDCs concentrations and the harmful health effects observed in population. In the present work, a method based on a simplified sample treatment involving steps of precipitation, evaporation and clean-up of the extracts with C18 followed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis for the determination of bisphenol A and its chlorinated derivatives (monochloro-, dichloro-, trichloro- and tetrachlorobisphenol A), parabens (methyl-, ethyl-, propyl- and butylparaben) and benzophenone-UV filters (benzophenone -1,-2, -3, -6, -8 and 4-hydroxybenzophenone) in human breast milk samples is proposed and validated. The limits of detections found ranged from 0.02 to 0.05 ng mL(-1). The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. Recovery rates ranged from 91% to 110% and the precision (evaluated as relative standard deviation) was lower than 15% for all compounds, being within the acceptable limits for the selected bioanalytical method validation guide. The method was satisfactorily applied for the determination of these compounds in human breast milk samples collected from 10 randomly selected women. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Atmospheric pressure gas chromatography-time-of-flight-mass spectrometry (APGC-ToF-MS) for the determination of regulated and emerging contaminants in aqueous samples after stir bar sorptive extraction (SBSE).

    PubMed

    Pintado-Herrera, Marina G; González-Mazo, Eduardo; Lara-Martín, Pablo A

    2014-12-03

    This work presents the development, optimization and validation of a multi-residue method for the simultaneous determination of 102 contaminants, including fragrances, UV filters, repellents, endocrine disruptors, biocides, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and several types of pesticides in aqueous matrices. Water samples were processed using stir bar sorptive extraction (SBSE) after the optimization of several parameters: agitation time, ionic strength, presence of organic modifiers, pH, and volume of the derivatizing agent. Target compounds were extracted from the bars by liquid desorption (LD). Separation, identification and quantification of analytes were carried out by gas chromatography (GC) coupled to time-of-flight (ToF-MS) mass spectrometry. A new ionization source, atmospheric pressure gas chromatography (APGC), was tested. The optimized protocol showed acceptable recovery percentages (50-100%) and limits of detection below 1ngL(-1) for most of the compounds. Occurrence of 21 out of 102 analytes was confirmed in several environmental aquatic matrices, including seawater, sewage effluent, river water and groundwater. Non-target compounds such as organophosphorus flame retardants were also identified in real samples by accurate mass measurement of their molecular ions using GC-APGC-ToF-MS. To the best of our knowledge, this is the first time that this technique has been applied for the analysis of contaminants in aquatic systems. By employing lower energy than the more widely used electron impact ionization (EI), AGPC provides significant advantages over EI for those substances very susceptible to high fragmentation (e.g., fragrances, pyrethroids). Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Improved sample treatment for the determination of 17 strong sorbed quinolone antibiotics from compost by ultra high performance liquid chromatography tandem mass spectrometry.

    PubMed

    Dorival-García, N; Labajo-Recio, C; Zafra-Gómez, A; Juárez-Jiménez, B; Vílchez, J L

    2015-06-01

    The use of compost from sewage sludge for agricultural application is nowadays increasing, since composting is recognized as one of the most important recycling options for this material, being a source of nutrients for plants but also of contamination by persistent pollutants. In the present work, a multi-residue analytical method for the determination of 17 quinolone antibiotic residues in compost using multivariate optimization strategies and ultra high performance liquid chromatography-tandem mass spectrometry has been developed. It is based on the use of microwave-assisted extraction at drastic conditions with ACN:m-phosphoric acid (1% w/v) for 5 min at 120°C, in order to achieve a quantitative extraction of the compounds (>76% of extraction recovery). Extracts were cleaned-up by salt-assisted liquid-liquid extraction (SALLE) with NaCl at pH 1.5 (with HClO4) and then using a dispersive sorbent (PSA). After LC separation, the MS conditions, in positive electrospray ionization mode (ESI), were individually optimized for each analyte to obtain maximum sensitivity in the selected reaction monitoring mode (SRM). The analytes were separated in less than 7 min. Cincophen was used as surrogate standard. The limits of detection ranged from 0.2 to 0.5 ng g(-1), and the limits of the quantification from 0.5 to 1.5 ng g(-1), while intra- and inter-day variability (% RSD) was under 7% in all cases. A recovery assay was performed with spiked samples. Recoveries ranging from 95.3% to 106.2% were obtained. Cleanup procedure reduced significantly matrix effects, which constitutes an important achievement, considering the important drawbacks of matrix components in quality and validation parameters. This method was applied to several commercial compost samples. Only 6 of the studied antibiotics were not detected in any of the samples. The antibiotics with the highest concentrations were ciprofloxacin (836 ng g(-1)), ofloxacin (719 ng g(-1)), and enrofloxacin (674 ng g(-1)), which were also the only ones found in all the analyzed samples. The results showed that this method could also be potentially adapted for the analysis of other strong sorbed basic pharmaceuticals in solid environmental matrices. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Development of a solid-phase microextraction gas chromatography with microelectron-capture detection method for a multiresidue analysis of pesticides in bovine milk.

    PubMed

    Fernandez-Alvarez, Maria; Llompart, Maria; Lamas, J Pablo; Lores, Marta; Garcia-Jares, Carmen; Cela, Rafael; Dagnac, Thierry

    2008-06-09

    A simple and rapid method based on solid-phase microextraction (SPME) technique followed by gas chromatography with microelectron-capture detection (GC-microECD) was developed for the simultaneous determination of more than 30 pesticides (pyrethroids and organochlorinated among others) in milk. To our knowledge, this is the first application of SPME for the determination of pyrethroid pesticides in milk. Negative matrix effects due to the complexity and lipophility of the studied matrix were reduced by diluting the sample with distilled water. A 2(5-1) fractional factorial design was performed to assess the influence of several factors (type of fiber coating, sampling mode, stirring, extraction temperature, and addition of sodium chloride) on the SPME procedure and to determine the optimal extraction conditions. After optimization of all the significant variables and interactions, the recommended procedure was established as follows: DSPME (using a polydimethylsiloxane (PDMS)/divinylbenzene (DVB) coating) of 1 mL of milk sample diluted with Milli-Q water (1:10 dilution ratio), at 100 degrees C, under stirring for 30 min. The proposed method showed good linearity and high sensitivity, with limits of detection (LOD) at the sub-ng mL(-1) level. Within a day and among days precisions were also evaluated (R.S.D.<15%). One of the most important attainments of this work was the use of external calibration with milk-matched standards to quantify the levels of the target analytes. The method was tested with liquid and powdered milk samples with different fat contents covering the whole commercial range. The efficiency of the extraction process was studied at several analyte concentration levels obtaining high recoveries (>80% in most cases) for different types of full-fat milks. The optimized procedure was validated with powdered milk certified reference material, which was quantified using external calibration and standard addition protocols. Finally, the DSPME-GC-microECD methodology was applied to the analysis of milk samples collected in farms of dairy cattle from NW Spain.

  18. Multi-residue method for determination of 58 pesticides, pharmaceuticals and personal care products in water using solvent demulsification dispersive liquid-liquid microextraction combined with liquid chromatography-tandem mass spectrometry.

    PubMed

    Caldas, Sergiane Souza; Rombaldi, Caroline; Arias, Jean Lucas de Oliveira; Marube, Liziane Cardoso; Primel, Ednei Gilberto

    2016-01-01

    A rapid and efficient sample pretreatment using solvent-based de-emulsification dispersive liquid-liquid microextraction (SD-DLLME) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was studied for the extraction of 58 pharmaceuticals and personal care products (PPCPs) and pesticides from water samples. Type and volume of extraction and disperser solvents, pH, salt addition, amount of salt and type of demulsification solvent were evaluated. Limits of quantification (LOQ) in the range from 0.0125 to 1.25 µg L(-1) were reached, and linearity was in the range from the LOQ of each compound to 25 μg L(-1). Recoveries ranged from 60% to 120% for 84% of the compounds, with relative standard deviations lower than 29%. The proposed method demonstrated, for the first time, that sample preparation by SD-DLLME with determination by LC-MS/MS can be successfully used for the simultaneous extraction of 32 pesticides and 26 PPCPs from water samples. The entire procedure, including the extraction of 58 organic compounds from the aqueous sample solution and the breaking up of the emulsion after extraction with water, rather than with an organic solvent, was environmentally friendly. In addition, this technique was less expensive and faster than traditional techniques. Finally, the analytical method under study was successfully applied to the analysis of all 58 pesticides and PPCPs in surface water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Multi-residue determination of seventeen sulfonamides and five tetracyclines in fish tissue using a multi-stage LC-ESI-MS/MS approach based on advanced mass spectrometric techniques.

    PubMed

    Dasenaki, Marilena E; Thomaidis, Nikolaos S

    2010-07-05

    A strategy was newly developed to rapidly screen seventeen sulfonamides and five tetracyclines in a single run from fish tissues using ultra-high performance liquid chromatography (UHPLC) coupled with comprehensive mass spectrometric approaches, including precursor-ion scan and data dependent scan. The product ions for precursor-ion scanning were selected by studying the MS/MS fragmentation of the analytes. All sulfonamides share the same diagnostic product ion at m/z 156 in positive MS/MS scan, while for tetracycline antibiotics the diagnostic product ion was proved to be at m/z 153.8. Further characterization of each compound was performed using a data dependent scan. Separation was performed on a Zorbax Eclipse Plus C18 column with a gradient elution using acetonitrile - 0.1% formic acid mobile phase at a flow rate of 0.1 mL min(-1). This approach has proven to be a powerful, highly selective, and sensitive tool for rapid screening and detection of non-targeted components in fish tissue and requires a minimum sample preparation such as one generic extraction step with MeOH:ACN 50:50 (v/v) acidified with 0.05% formic acid. The method has also been applied successfully to porcine and poultry meat. The validation of such a screening method was performed for the first time according to Commission Decision 2002/657/EC and satisfactory method performance characteristics were achieved. Copyright 2010 Elsevier B.V. All rights reserved.

  20. Determination of 28 pesticides applied on two tomato cultivars with a different surface/weight ratio of the berries, using a multiresidue GC-MS/MS method.

    PubMed

    Dedola, Fabrizio; Cabizza, Maddalena; Satta, Maurizio

    2014-01-01

    The behavior of 28 pesticides on two tomato cultivars with a different surface/weight (S/W) ratio of the berries (S/W, Birikino vs. Tombola) was studied, in order to provide appropriate indications about their persistence on crops reaching the pre-harvest interval (PHI). Quantitative analysis was performed using a GC MS/MS method. Birikino cv. (BIR) was a "cherry type tomato" with a double S/W ratio compared with Tombola cv. (TOM). The results showed a different pesticide behavior. Azoxystrobin, Boscalid, Bupirimate, Difenoconazole, Etofenprox, Iprodione, Mepanipyrim, Myclobutanil, Tebuconazole, Zoxamide, Metalaxyl M, Pyrimethanil, Tetraconazole, Benalaxyl, Cyprodinil, Fenamidone, Famoxadone and Fludioxonil immediately after treatments showed residues on BIR higher than TOM, and this behavior is consistent with its greater exposed surface. BIR showed higher decay rates of these pesticides during the whole trial, nevertheless residue averages remained higher than TOM reaching the time of harvest. Residues at the PHI were all below their Maximum Residue Levels (MRLs), but data indicated that they could exceed their legal limits especially if the above-mentioned active ingredients were employed more than once per crop cycle on cherry type tomatoes. As regards to Chlorpyrifos, Chlorpyrifos methyl, Triadimenol, Pyridaben and Tebufenpyrad, no different residual behavior related to S/W ratio of the cultivars was observed. Even in this case, residues at the PHI were all below MRLs. As for Cyfluthrin, Deltamethrin, Lambda cyhalothrin, Etoxazole and Cyproconazole, residues were lower than the limit of quantitation (LOQ) of the analytical method just after the treatment, according to their low doses of employment.

  1. Pesticide residues in honeybees, honey and bee pollen by LC-MS/MS screening: reported death incidents in honeybees.

    PubMed

    Kasiotis, Konstantinos M; Anagnostopoulos, Chris; Anastasiadou, Pelagia; Machera, Kyriaki

    2014-07-01

    The aim of this study was to investigate reported cases of honeybee death incidents with regard to the potential interrelation to the exposure to pesticides. Thus honeybee, bee pollen and honey samples from different areas of Greece were analyzed for the presence of pesticide residues. In this context an LC-ESI-MS/MS multiresidue method of total 115 analytes of different chemical classes such as neonicotinoids, organophosphates, triazoles, carbamates, dicarboximides and dinitroanilines in honeybee bodies, honey and bee pollen was developed and validated. The method presents good linearity over the ranges assayed with correlation coefficient values r(2)≥0.99, recoveries ranging for all matrices from 59 to 117% and precision (RSD%) values ranging from 4 to 27%. LOD and LOQ values ranged - for honeybees, honey and bee pollen - from 0.03 to 23.3 ng/g matrix weight and 0.1 up to 78 ng/g matrix weight, respectively. Therefore this method is sufficient to act as a monitoring tool for the determination of pesticide residues in cases of suspected honeybee poisoning incidents. From the analysis of the samples the presence of 14 active substances was observed in all matrices with concentrations ranging for honeybees from 0.3 to 81.5 ng/g, for bee pollen from 6.1 to 1273 ng/g and for honey one sample was positive to carbendazim at 1.6 ng/g. The latter confirmed the presence of such type of compounds in honeybee body and apicultural products. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Large-scale pesticide testing in olives by liquid chromatography-electrospray tandem mass spectrometry using two sample preparation methods based on matrix solid-phase dispersion and QuEChERS.

    PubMed

    Gilbert-López, Bienvenida; García-Reyes, Juan F; Lozano, Ana; Fernández-Alba, Amadeo R; Molina-Díaz, Antonio

    2010-09-24

    In this work we have evaluated the performance of two sample preparation methodologies for the large-scale multiresidue analysis of pesticides in olives using liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS). The tested sample treatment methodologies were: (1) liquid-liquid partitioning with acetonitrile followed by dispersive solid-phase extraction clean-up using GCB, PSA and C18 sorbents (QuEChERS method - modified for fatty vegetables) and (2) matrix solid-phase dispersion (MSPD) using aminopropyl as sorbent material and a final clean-up performed in the elution step using Florisil. An LC-MS/MS method covering 104 multiclass pesticides was developed to examine the performance of these two protocols. The separation of the compounds from the olive extracts was achieved using a short C18 column (50 mm x 4.6 mm i.d.) with 1.8 microm particle size. The identification and confirmation of the compounds was based on retention time matching along with the presence (and ratio) of two typical MRM transitions. Limits of detection obtained were lower than 10 microgkg(-1) for 89% analytes using both sample treatment protocols. Recoveries studies performed on olives samples spiked at two concentration levels (10 and 100 microgkg(-1)) yielded average recoveries in the range 70-120% for most analytes when QuEChERS procedure is employed. When MSPD was the choice for sample extraction, recoveries obtained were in the range 50-70% for most of target compounds. The proposed methods were successfully applied to the analysis of real olives samples, revealing the presence of some of the target species in the microgkg(-1) range. Besides the evaluation of the sample preparation approaches, we also discuss the use of advanced software features associated to MRM method development that overcome several limitations and drawbacks associated to MS/MS methods (time segments boundaries, tedious method development/manual scheduling and acquisition limitations). This software feature recently offered by different vendors is based on an algorithm that associates retention time data for each individual MS/MS transition, so that the number of simultaneously traced transitions throughout the entire chromatographic run (dwell times and sensitivity) is maximized. Copyright 2010 Elsevier B.V. All rights reserved.

  3. Determination of pesticide residues in animal origin baby foods by gas chromatography coupled with triple quadrupole mass spectrometry.

    PubMed

    Amendola, Graziella; Pelosi, Patrizia; Attard Barbini, Danilo

    2015-01-01

    A simple, fast and multiresidue method for the determination of pesticide residues in baby foods of animal origin has been developed in order to check the compliance with the Maximum Residue Levels (MRLs) set at a general value of 0.01 mg/kg by Commission Directive 2006/125/EC for infant foods. The main classes of organochlorine, organophosphorus and pyrethroid compounds have been considered, which are mainly fat soluble pesticides. The analytical procedure consists in the extraction of baby food samples by acetonitrile (ACN) followed by a clean up using C18 solid-phase extraction column eluted with ACN. The compounds were determined by gas chromatography-triple quadrupole mass spectrometry equipped with a Programmed Temperature Vaporizer (PTV) injection and a backflush system. In order to compensate for matrix effects PTV and matrix matched standard calibrations have been used. The method has been fully validated for 57 pesticides according to the Document SANCO/12571/2013. Accuracy and precision (repeatability) have been studied by recoveries at two spiking levels, the Limit of Quantitation (LOQ) (0.003-0.008 mg/kg) and 10 time greater (0.03-0.08 mg/kg), and the results were in the acceptable range of 70-120% with Relative Standards Deviations (RSD) ≤20%. Selectivity, linearity, LOQ and uncertainty of measurement were also determined for all the compounds. The method has been also applied for the analysis of 18 baby food animal origin samples, bought form the local market in Rome (Italy), and no pesticide in the scope of the method has been found above the MRL or the LOQ.

  4. Monitoring of estrogens, pesticides and bisphenol A in natural waters and drinking water treatment plants by solid-phase extraction-liquid chromatography-mass spectrometry.

    PubMed

    Rodriguez-Mozaz, Sara; de Alda, Maria J López; Barceló, Damià

    2004-08-06

    A multi-residue analytical method has been developed for the determination of various classes of selected endocrine disruptors. This method allows the simultaneous extraction and quantification of different estrogens (estradiol, estrone, estriol, estradiol-17-glucuronide, estradiol diacetate, estrone-3-sulfate, ethynyl estradiol and diethylstilbestrol), pesticides (atrazine, simazine, desethylatrazine, isoproturon and diuron), and bisphenol A in natural waters. In the method developed, 500 ml of water are preconcentrated on LiChrolut RP-18 cartridges. Further analysis is carried out by liquid chromatography-mass spectrometry (LC-MS) using atmospheric pressure chemical ionisation (APCI) in the positive ion mode for determination of pesticides and electrospray in the negative ionisation mode for determination of estrogens and bisphenol A. Recoveries for most compounds were between 90 and 119%, except for bisphenol A (81%) and diethylstilbestrol (70%), with relative standard deviations below 20%. Limits of detection ranged between 2 and 15 ng/l. The method was used to study the occurrence of the selected pollutants in surface and groundwater used for abstraction of drinking water in a waterworks and to evaluate the removal efficiency of the different water treatments applied. Water samples from the river, the aquifer, and after each treatment stage (sand filtration, ozonation, activated carbon filtration and post-chlorination) were taken monthly from February to August of 2002. The presence in river water of atrazine, simazine, diuron and bisphenol A were relatively frequent at concentrations usually below 0.1 microg/l. Lower levels, below 0.02 microg/l, were usual for isoproturon. Estrone-3-sulfate and estrone were detected occasionally in the river. Most of the compounds were completely removed during the water treatment, especially after activated carbon filtration.

  5. Simultaneous enantiomeric analysis of eight pesticides in soils and river sediments by chiral liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhao, Pengfei; Zhao, Jing; Lei, Shuo; Guo, Xingjie; Zhao, Longshan

    2018-08-01

    A rapid and sensitive multi-residue method was developed for the simultaneous quantification of eight chiral pesticides (including diniconazole, metalaxyl, paclobutrazol, epoxiconazole, myclobutanil, hexaconazole, napropamide and isocarbophos) at enantiomeric levels in environmental soils and sediments using chiral liquid chromatography-tandem mass spectrometry based on a combined pretreatment of matrix solid-phase dispersion and dispersive liquid-liquid microextraction (MSPD-DLLME). Under optimized conditions, 0.1 g of solid sample was dispersed with 0.4 g of C18-bonded silica sorbent, and 3 mL of methanol was used for eluting the analytes. The collected eluant was dried and then further purified by DLLME with 550 μL of dichloromethane and 960 μL of acetonitrile as extraction and disperser solvent, respectively. The established method was validated and found to be linear, precise, and accurate over the concentration range of 2-500 ng g -1 for epoxiconazole, paclobutrazol and metalaxyl and 4-500 ng g -1 for isocarbophos, hexaconazole, myclobutanil, diniconazole and napropamide. Recoveries of sixteen enantiomers varied from 87.0 to 104.1% and the relative standard deviations (RSD) were less than 10.1%. Method detection and quantification limits (MDLs and MQLs) varied from 0.22 to 1.54 ng g -1 and from 0.91 to 4.00 ng g -1 , respectively. Finally, the method was successfully applied to analyze the enantiomeric composition of the eight chiral pesticides in environmental solid matrices, which will help better understand the behavior of individual enantiomer and make accurate risk assessment on the ecosystem. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. A multi-residue method for the analysis of pesticides and pesticide degradates in water using HLB solid-phase extraction and gas chromatography-ion trap mass spectrometry

    USGS Publications Warehouse

    Hladik, M.L.; Smalling, K.L.; Kuivila, K.M.

    2008-01-01

    A method was developed for the analysis of over 60 pesticides and degradates in water by HLB solid-phase extraction and gas-chromatography/mass spectrometry. Method recoveries and detection limits were determined using two surface waters with different dissolved organic carbon (DOC) concentrations. In the lower DOC water, recoveries and detection limits were 80%-108% and 1-12 ng/L, respectively. In the higher DOC water, the detection limits were slightly higher (1-15 ng/L). Additionally, surface water samples from four sites were analyzed and 14 pesticides were detected with concentrations ranging from 4 to 1,200 ng/L. ?? 2008 Springer Science+Business Media, LLC.

  7. Validation and application of a multiresidue method based on liquid chromatography-tandem mass spectrometry for evaluating the plant uptake of 74 microcontaminants in crops irrigated with treated municipal wastewater.

    PubMed

    Martínez-Piernas, A B; Polo-López, M I; Fernández-Ibáñez, P; Agüera, A

    2018-01-26

    Reuse of treated wastewater for agricultural purposes can mitigate water stress in some regions where the lack of water is an extended problem. However, the environmental long-term consequences of this practice are still unknown. It is demonstrated that using reclaimed water for irrigation lead to accumulation and translocation of some microcontaminants (MCs) in soil and crops. However, so far, only a small group of contaminants has been investigated. This study aims to develop and validate a simple and efficient multiresidue method based on QuEChERs (Quick, Easy, Cheap, Effective and Rugged) extraction coupled to liquid chromatography tandem mass spectrometry (LC-MS/MS). The novelty of the study relays in the large number of MCs analyzed (74), some of them not previously investigated, in three commodities (lettuce, radish and strawberry). Optimized conditions yielded good results for the three commodities under study. Up to 84% of the compounds were recovered within a 70-120% range, with good repeatability (relative standard deviations below 20% in most cases). Method detection (MDLs) and quantification limits (MQLs) ranged from 0.01 to 2 ng/g. The proposed method was successfully applied to assess the potential uptake of MCs by lettuce and radish crops irrigated with wastewater under controlled conditions for 3 and 1.5 months, respectively. 12 compounds were detected in the crops with concentrations ranging from 0.03 to 57.6 ng/g. N-Formyl-4-aminoantipyrine (4FAA) was the most concentrated compound. The application of this method demonstrated for the first time the accumulation of 5 contaminants of emerging concern (CECs) not previously reported: 4FAA, N-Acetyl-4-aminoantipyrine (4AAA), hydrochlorothiazide, mepivacaine and venlafaxine. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Validation of a method for the determination of 120 pesticide residues in apples and cucumbers by LC-MS/MS.

    PubMed

    Ramadan, Gouda; Al Jabir, Muna; Alabdulmalik, Najat; Mohammed, Ali

    2016-05-01

    Most countries have clearly defined regulations governing the use of pesticides in agricultural activity. The application of pesticides in agriculture usually leads to a residual amount of these pesticides on food products such as fruit and vegetables. The presence of pesticide residues on these foods destined for human consumption may pose food safety risks to consumers. To protect consumers, national authorities have established maximum limits for pesticide residues in foods. These limits can only be enforced if there are methods available to detect and monitor their concentrations in the applicable food products. To support the enforcement of this legislation, we have developed a multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of 120 pesticide residues in apples and cucumbers which has been validated and implemented in the routine monitoring and surveillance programme for these pesticides. In this method, apple and cucumber samples are extracted using the QuEChERS method (quick, easy, cheap, effective, rugged, and safe) and the extracts were analyzed directly by LC-MS/MS. The mean recoveries at three different concentrations of 0.01 µg/g , 0.05 µg/g, and 0.1 µg/g over the analytical range varied between 70 and 120%. The repeatability of the method expressed as %RSD was less than 20%. The limit of detection (LOD) of the method ranged between 0.0014 and 0.0110 µg/g for apples and between 0.0012 and 0.0075 µg/g for cucumbers. The limit of quantification (LOQ) of the method was 0.01 µg/g for apples and cucumbers. The method has been used for the analysis of over 600 apple and 550 cucumber samples over the past two years. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Optimization of separation and detection conditions for the multiresidue analysis of pesticides in grapes by comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry.

    PubMed

    Banerjee, Kaushik; Patil, Sangram H; Dasgupta, Soma; Oulkar, Dasharath P; Patil, Shubhangi B; Savant, Rahul; Adsule, Pandurang G

    2008-05-09

    A comprehensive GCxGC-TOFMS method was optimized for multiresidue analysis of pesticides using a combination of a non-polar (RTX-5MS, 10 m x 0.18 mm x 0.2 microm) and a polar capillary column (TR-50MS, 1 m x 0.1 mm x 0.1 microm), connected in series through a dual stage thermal modulator. The method resolved the co-elution problems as observed in full scan one-dimensional GC-MS analysis and allowed chromatographic separation of 51 pesticides within 24 min run time with library-searchable mass spectrometric confirmation. Four pesticides, viz. chlorpyrifos-methyl, vinclozoline, parathion-methyl and heptachlor could be baseline separated on GCxGC, which were otherwise closely eluting and interfering each other's detection in 1D GC-MS run. Similarly, it could be possible to separate myclobutanil, buprofezin, flusilazole and oxyfluorfen on GCxGC. Although in 1D GC-MS, these closely eluting compounds could be identified through deconvolution algorithm and 'peak-find' option of the Chromatof software but the spectral purity significantly improved on GCxGC analysis. Thorough optimization was accomplished for the oven temperature programming, ion source temperature and GCxGC parameters like modulation period, duration of hot pulses, modulation-offset temperature, acquisition rate, etc. to achieve best possible separation of the test compounds. The limit of detection significantly improved by 2-12 times on GCxGC-TOFMS against GC-TOFMS because of sharper and narrower peak shapes. The method was tested for grape matrix after preparing the samples using previously described method and recoveries of the entire test pesticides were within 70-110% at 10 ng/g level of fortification. GCxGC-TOFMS was found to be an excellent technique for library-based screening of pesticides with high accuracy and sensitivity.

  10. Rapid and Simultaneous Analysis of 360 Pesticides in Brown Rice, Spinach, Orange, and Potato Using Microbore GC-MS/MS.

    PubMed

    Lee, Jonghwa; Kim, Leesun; Shin, Yongho; Lee, Junghak; Lee, Jiho; Kim, Eunhye; Moon, Joon-Kwan; Kim, Jeong-Han

    2017-04-26

    A multiresidue method for the simultaneous and rapid analysis of 360 pesticides in representative agricultural produce (brown rice, orange, spinach, and potato) was developed using a modified QuEChERS procedure combined with gas chromatography-tandem mass spectrometry (GC-MS/MS). Selected reaction monitoring transition parameters (e.g., collision energy, precursor and product ions) in MS/MS were optimized to achieve the best selectivity and sensitivity for a wide range of GC-amenable pesticides. A short (20 m) microbore (0.18 mm i.d.) column resulted in better signal-to-noise ratio with reduced analysis time than a conventional narrowbore column (30 m × 0.25 mm i.d.). The priming injection dramatically increased peak areas by masking effect on a new GC liner. The limit of quantitation was <0.01 mg/kg, and the correlation coefficients (r 2 ) of matrix-matched standards were >0.99 within the range of 0.0025-0.1 mg/kg. Acetonitrile with 0.1% formic acid without additional buffer salts was used for pesticide extraction, whereas only primary-secondary amine (PSA) was used for dispersive solid phase extraction (dSPE) cleanup, to achieve good recoveries for most of the target analytes. The recoveries ranged from 70 to 120% with relative standard deviations of ≤20% at 0.01 and 0.05 mg/kg spiking levels (n = 6) in all samples, indicating acceptable accuracy and precision of the method. Seventeen real samples from local markets were analyzed by using the optimized method, and 14 pesticides in 11 incurred samples were found at below the maximum residue limits.

  11. A multi-residue method for characterization and determination of atmospheric pesticides measured at two French urban and rural sampling sites.

    PubMed

    Baraud, Laurent; Tessier, Didier; Aaron, Jean-Jacques; Quisefit, Jean-Paul; Pinart, Johann

    2003-12-01

    The extensive use of pesticides to protect agricultural crops can result in the transfer of these compounds into the atmosphere and their diffusion towards urban areas. Precise evaluation of the geographic impact of this type of pollution is important environmentally. In this paper, analytical methods for the sampling, characterization, and determination of agricultural pesticides in air were developed; the methods were then applied in the Paris and Champagne regions. Sixteen pesticides belonging to nine chemical families were monitored. Sampling was carried out in urban (Paris) and rural (Aube district) sites, utilizing either a high-volume pump (12.5 m3 h(-1)) (urban site) or a low-volume pump (2.3 m3 h(-1)) for the rural site. Quartz filters and polyurethane foams (PUF) were used for sampling in all cases. After extracting the samples and concentrating the recovered solutions, high-performance liquid chromatography (HPLC) analysis with UV detection was performed. Identification of the pesticides was confirmed by applying to the HPLC measurements a novel UV-detection procedure based on the normalized absorbance variation with wavelength (Noravawa procedure). The presence of metsulfuron methyl, isoproturon, linuron, deltamethrin (and/or malathion), and chlorophenoxy acids (2,4-D and MCPP) was found at the urban sampling site at levels ranging from about 1 to 1130 ng m(-3) of air, depending on the compound and sampling period. On the rural sampling site residues of isoproturon, deltamethrin (and/or malathion), MCPP, and 2,4-D were generally detected at higher levels (19-5130 ng m(-3)) than on the urban site, as expected. The effects of the weather conditions and agricultural activity on the atmospheric concentrations of pesticides are discussed, as are long-range atmospheric transfer processes for these pesticides.

  12. Determination of nandrolone metabolites in human urine: comparison between liquid chromatography/tandem mass spectrometry and gas chromatography/mass spectrometry.

    PubMed

    Buiarelli, Francesca; Giannetti, Luigi; Jasionowska, Renata; Cruciani, Claudia; Neri, Bruno

    2010-07-15

    Nandrolone (19-nortestosterone) is an androgenic anabolic steroid illegally used as a growth-promoting agent in animal breeding and as a performance enhancer in athletics. Therefore, its use was officially banned in 1974 by the Medical Commission of the International Olympic Committee (IOC). Following nandrolone administration, the main metabolites in humans are 19-norandrosterone, 19-norethiocolanolone and 19-norepiandrosterone, and their presence in urine is the basis of detecting its abuse. The present work was undertaken to determine, in human urine, nandrolone metabolites (phase I and phase II) by developing and comparing multiresidue liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) methods. A double extraction by solid-phase extraction (SPE) was necessary for the complete elimination of the interfering compounds. The proposed methods were also tested on a real positive sample, and they allow us to determine the conjugated/free fractions ratio reducing the risk of false positive or misleading results and they should allow laboratories involved in doping control analysis to monitor the illegal use of steroids. The advantages of LC/MS/MS over GC/MS (which is the technique mainly used) include the elimination of the hydrolysis and derivatization steps: it is known that during enzymatic hydrolysis several steroids can be converted into related compounds and deconjugation is not always 100% effective. The validation parameters for the two methods were similar (limit of quantification (LOQ) <1 ng/mL and percentage coefficient of variance (CV%) <16.4), and both were able to confirm unambiguously all the analytes, thus confirming the validity of both techniques. Copyright 2010 John Wiley & Sons, Ltd.

  13. Occurrence of the herbicide glyphosate and its metabolite AMPA in surface waters in Switzerland determined with on-line solid phase extraction LC-MS/MS.

    PubMed

    Poiger, Thomas; Buerge, Ignaz J; Bächli, Astrid; Müller, Markus D; Balmer, Marianne E

    2017-01-01

    Glyphosate is currently one of the most important herbicides worldwide. Its unique properties provide for a wide range of uses in agriculture but also in non-agricultural areas. At the same time, its zwitterionic nature prevents the inclusion in multi-residue analytical methods for environmental monitoring. Consequently, despite its extensive use, data on occurrence of glyphosate in the aquatic environment is still scarce. Based on existing methods, we developed a simplified procedure for the determination of glyphosate and its main metabolite aminomethylphosphonic acid (AMPA) in water samples using derivatization with fluorenylmethyl chloroformate FMOC-Cl, combined with on-line solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS) detection. This method was extensively tested on over 1000 samples of surface water, groundwater, and treated wastewater and proved to be simple, sensitive, and reliable. Limits of quantification of 0.005 μg/L were routinely achieved. Glyphosate and AMPA were detected in the vast majority of stream water samples in the area of Zurich, Switzerland, with median concentrations of 0.11 and 0.20 μg/L and 95th percentile concentrations of 2.1 and 2.6 μg/L, respectively. Stream water data and data from treated wastewater indicated that non-agricultural uses may significantly contribute to the overall loads of glyphosate and AMPA in surface waters. In the investigated groundwater samples, selected specifically because they had shown presence of other herbicides in previous monitoring programs, glyphosate and AMPA were generally not detected, except for two monitoring sites in Karst aquifers, indicating that these compounds show much less tendency for leaching.

  14. Multiresidue determination and potential risks of emerging pesticides in aquatic products from Northeast China by LC-MS/MS.

    PubMed

    Fu, Lei; Lu, Xianbo; Tan, Jun; Wang, Longxing; Chen, Jiping

    2018-01-01

    A simple method for determining 33 pesticides with a wide polarity range (logK ow 0.6-4.5) in aquatic products was developed based on LC-MS/MS. The target analytes included three types of widely used pesticides: insecticides, fungicides and herbicides. Based on the optimization of ultrasonic assisted extraction and GPC clean-up procedures, the matrix effect, extraction recoveries and LOD were improved distinctively. LOQ of this method was below 0.5ng/g for all pesticides, which is superior to values in the literature, and the matrix effect was reduced effectively (-14.7% to 7.5%). The method was successfully applied to investigate the pesticide residue levels of twenty-five samples including seven common kinds of fishes from Northeast China. The results showed that all targeted pesticides were present in the fish samples; however, their levels were low, except for atrazine, linuron, ethoprophos, tetrachlorvinphos, acetochlor and fenthion. Atrazine and linuron caught our attention because the concentrations of atrazine in fish samples from Liaoning province were in the range of 0.5-8ng/g (w/w) with mean concentration of 2.3ng/g, which were far above those of other pesticides. The levels of linuron were in the range of 0.6-6ng/g (mean concentration 2.8ng/g), which were the highest among all targeted pesticides in the Inner Mongolia. This is the first systematic investigation on the characteristics and levels of these pesticides in aquatic products from northeast China. Considering their toxicity and bioaccumulation, the potential risk of atrazine and linuron from consuming aquatic products should be paid more attention. Copyright © 2017. Published by Elsevier B.V.

  15. Signal processing to evaluate parameters affecting SPE for multi-residue analysis of personal care products.

    PubMed

    Pietrogrande, Maria Chiara; Basaglia, Giulia; Dondi, Francesco

    2009-05-01

    This paper discusses the development of a comprehensive method for the simultaneous analysis of personal care products (PCPs) based on SPE and GC-MS. The method was developed on 29 target compounds to represent PCPs belonging to different chemical classes: surfactants in detergents (alkyl benzenes), fragrances in cosmetics (nitro and polycyclic musks), antioxidants and preservatives (phenols), plasticizers (phthalates) displaying a wide range of volatility, polarity, water solubility. In addition to the conventional C(18) stationary phase, a surface modified styrene divinylbenzene polymeric phase (Strata X SPE cartridge) has been investigated as suitable for the simultaneous extraction of several PCPs with polar and non-polar characteristics. For both sorbents different solvent compositions and eluting conditions were tested and compared in order to achieve high extraction efficiency for as many sample components as possible. Comparison of the behavior of the two cartridges reveals that, overall, Strata-X provides better efficiency with extraction recovery higher than 70% for most of the PCPs investigated. The best results were obtained under the following operative conditions: an evaporation temperature of 40 degrees C, elution on Strata-X cartridge using a volume of 15 mL of ethyl acetate (EA) as solvent and operating with slow flow rate (-10 KPa). In addition to the conventional method based on peak integration, a chemometric approach based on the computation of the experimental autocovariance function (EACVF(tot)) was applied to the complex GC-MS signal: the percentage recovery and information on peak abundance distribution can be evaluated for each procedure step. The PC-based signal processing proved very helpful in assisting the development of the analytical procedure, since it saves labor and time and increases result reliability in handling GC complex signals.

  16. Matrix effects in pesticide multi-residue analysis by liquid chromatography-mass spectrometry.

    PubMed

    Kruve, Anneli; Künnapas, Allan; Herodes, Koit; Leito, Ivo

    2008-04-11

    Three sample preparation methods: Luke method (AOAC 985.22), QuEChERS (quick, easy, cheap, effective, rugged and safe) and matrix solid-phase dispersion (MSPD) were applied to different fruits and vegetables for analysis of 14 pesticide residues by high-performance liquid chromatography with electrospray ionization-mass spectrometry (HPLC/ESI/MS). Matrix effect, recovery and process efficiency of the sample preparation methods applied to different fruits and vegetables were compared. The Luke method was found to produce least matrix effect. On an average the best recoveries were obtained with the QuEChERS method. MSPD gave unsatisfactory recoveries for some basic pesticide residues. Comparison of matrix effects for different apple varieties showed high variability for some residues. It was demonstrated that the amount of co-extracting compounds that cause ionization suppression of aldicarb depends on the apple variety as well as on the sample preparation method employed.

  17. Multi-residue method for the determination of pesticides and pesticide metabolites in honeybees by liquid and gas chromatography coupled with tandem mass spectrometry--Honeybee poisoning incidents.

    PubMed

    Kiljanek, Tomasz; Niewiadowska, Alicja; Semeniuk, Stanisław; Gaweł, Marta; Borzęcka, Milena; Posyniak, Andrzej

    2016-02-26

    A method for the determination of 200 pesticides and pesticide metabolites in honeybee samples has been developed and validated. Almost 98% of compounds included in this method are approved to use within European Union, as active substances of plant protection products or veterinary medicinal products used by beekeepers to control mites Varroa destructor in hives. Many significant metabolites, like metabolites of imidacloprid, thiacloprid, fipronil, methiocarb and amitraz, are also possible to detect. The sample preparation was based on the buffered QuEChERS method. Samples of bees were extracted with acetonitrile containing 1% acetic acid and then subjected to clean-up by dispersive solid phase extraction (dSPE) using a new Z-Sep+ sorbent and PSA. The majority of pesticides, including neonicotionoids and their metabolites, were analyzed by liquid chromatography tandem mass spectrometry (LC-MS/MS) but some of pesticides, especially pyrethroid insecticides, were analyzed by gas chromatography tandem mass spectrometry (GC-MS/MS). The procedure was validated according to the Guidance document SANCO/12571/2013 at four concentration levels: 1, 5, 10 and 100 ng/g bees and verified in the international proficiency test. The analysis of bee samples spiked at the limit of quantification (LOQ) showed about 98% mean recovery value (trueness) and 97% of analytes showed recovery in the required range of 70-120% and RSDr (precision) below 20%. Linearity and matrix effects were also established. The LOQs of pesticides were in the range of 1-100 ng/g. The developed method allows determination of insecticides at concentrations of 10 ng/g or less, except abamectin and tebufenozide. LOQ values are lower than the median lethal doses LD50 for bees. The method was used to investigate more than 70 honeybee poisoning incidents. Data about detected pesticides and their metabolites are included. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Multi-residue methods for the determination of over four hundred pesticides in solid and liquid high sucrose content matrices by tandem mass spectrometry coupled with gas and liquid chromatograph.

    PubMed

    Lozowicka, Bozena; Ilyasova, Gulzhakhan; Kaczynski, Piotr; Jankowska, Magdalena; Rutkowska, Ewa; Hrynko, Izabela; Mojsak, Patrycja; Szabunko, Julia

    2016-05-01

    For the first time three methods: matrix solid phase dispersion (MSPD), original and modified QuEChERS, with and without clean up step were studied in order to evaluate the extraction efficiency of various classes of pesticides from solid and liquid high sucrose content matrices. Determinations over four hundred pesticides were performed by gas and liquid chromatography with triple quadrupole mass spectrometry (GC/LC/MS/MS) using multiple reaction monitoring. The proposed methods were validated on sugar beets and their technological product beet molasses. In general, the recoveries obtained for the original QuEChERS and MSPD method were lower (<70%) than for the modified QuEChERS without clean up in sugar beet and with clean up in beet molasses. Among these methods, high extraction yields were achieved as recommended in SANCO/12571/2013, with repeatability of 4.4-19.2% and within-laboratory reproducibility of 7.1-18.4% for citrate QuEChERS, whereas greater ruggedness were observed for MSPD. The limit of quantification (LOQ) at (the lowest MRL=0.01mgkg(-1)e.g. for oxamyl()) or below (0.005mgkg(-1)) the regulatory maximum residue level for the pesticides were achieved. The expanded measurement uncertainty was not higher than 30% for all target analytes. Matrix effects were compared and observed for both matrices at both gas and liquid chromatography. The most compounds showed signal enhancement and it was compensated by using matrix-matched calibration and modified QuEChERS characterized lower matrix effects. The confirmation of suitability citrate QuEChERS optimized method was to use for routine testing of several dozen samples determination and residue of epoxiconazole and tebuconazole (both at 0.01mgkg(-1)) in the samples of beet molasses and cyfluthrin (0.06mgkg(-1)) in sugar beet were found. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Development of a multi-residue enantiomeric analysis method for 9 pesticides in soil and water by chiral liquid chromatography/tandem mass spectrometry.

    PubMed

    Li, Yuanbo; Dong, Fengshou; Liu, Xingang; Xu, Jun; Chen, Xiu; Han, Yongtao; Liang, Xuyang; Zheng, Yongquan

    2013-04-15

    A novel and sensitive chiral liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous measuring individual enantiomers of 9 pesticides including herbicides, insecticides, and fungicides in soil and water. The separation and determination were performed using reversed-phase chromatography on an amylose chiral stationary phase, a Chiralpak AD-RH column, under gradient elution using a mixture of ACN-2mM ammonium acetate in water as the mobile phase at 0.45 mL/min flow rate. The effects of three cellulose-based columns and three amylose-based columns on the separation were also investigated. The QuEChERS (acronym for Quick, Easy, Cheap, Effective, Rugged and Safe) method and solid-phase extraction (SPE) were used for the extraction and clean-up of the soil and water samples, respectively. Parameters including the matrix effect, linearity, precision, accuracy and stability were undertaken. Under optimal conditions, the mean recoveries for all enantiomers from the soil and water samples were ranged from 77.8% to 106.2% with the relative standard deviations (RSD) less than 14.2%. Good linearity (at least R(2) ≥ 0.9986) was obtained for all studied analytes in the soil and water matrix calibration curves over the range from 2.0 to 125 μg/L. The limits of detection (LOD) for all enantiomers in the soil and water were less than 1.8 μg/kg or μg/L, whereas the limit of quantification (LOQ) did not exceed 5.0 μg/kg or μg/L. The results of the method validation confirm that this proposed method is convenient and reliable for the enantioselective determination of the enantiomers of 9 chiral pesticides in soil and water. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Validation of a method for simultaneous determination of nitroimidazoles, benzimidazoles and chloramphenicols in swine tissues by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Xia, Xi; Wang, Yuanyuan; Wang, Xia; Li, Yun; Zhong, Feng; Li, Xiaowei; Huang, Yaoling; Ding, Shuangyang; Shen, Jianzhong

    2013-05-31

    This paper presents a sensitive and confirmatory multi-residue method for the analysis of 23 veterinary drugs and metabolites belonging to three classes (nitroimidazoles, benzimidazoles, and chloramphenicols) in porcine muscle, liver, and kidney. After extracted with ethyl acetate and basic ethyl acetate sequentially, the crude extracts were defatted with hexane and further purified using Oasis MCX solid-phase extraction cartridges. Rapid determination was carried out by ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry. Data acquisition was performed under positive and negative mode simultaneously. Recoveries based on matrix-matched calibrations for meat, liver, and kidney ranged from 50.6 to 108.1%. The method quantification limits were in the range of 3-100ng/kg. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. QuEChERS sample preparation for the determination of pesticides and other organic residues in environmental matrices: a critical review.

    PubMed

    Bruzzoniti, Maria Concetta; Checchini, Leonardo; De Carlo, Rosa Maria; Orlandini, Serena; Rivoira, Luca; Del Bubba, Massimo

    2014-07-01

    Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) is an extraction and clean-up technique originally developed for recovering pesticide residues from fruits and vegetables. Since its introduction, and until December 2013, about 700 papers have been published using the QuEChERS technique, according to a literature overview carried out using SciFinder, Elsevier SciVerse, and Google search engines. Most of these papers were dedicated to pesticide multiresidue analysis in food matrices, and this topic has been thoroughly reviewed over recent years. The QuEChERS approach is now rapidly developing beyond its original field of application to analytes other than pesticides, and matrices other than food, such as biological fluids and non-edible plants, including Chinese medicinal plants. Recently, the QuEChERS concept has spread to environmental applications by analyzing not only pesticides but also other compounds of environmental concern in soil, sediments, and water. To the best of our knowledge, QuEChERS environmental applications have not been reviewed so far; therefore, in this contribution, after a general discussion on the evolution and changes of the original QuEChERS method, a critical survey of the literature regarding environmental applications of conventional and modified QuEChERS methodology is provided. The overall recoveries obtained with QuEChERS and other extraction approaches (e.g., accelerated solvent extraction, ultrasonic solvent extraction, liquid/solid extraction, and soxhlet extraction) were compared, providing evidence for QuEChERS higher recoveries for various classes of compounds, such as biopesticides, chloroalkanes, phenols, and perfluoroalkyl substances. The role of physicochemical properties of soil (i.e., clay and organic carbon content, as well as cation exchange capacity) and target analytes (i.e., log KOW, water solubility, and vapor pressure) were also evaluated in order to interpret recovery and matrix effect data.

  2. Multiresidue determination of carbamate, organochlorine, organophosphorus, and dicarboximide pesticides in lettuce by GC/MS.

    PubMed

    Da Silva, Rogério Luiz; Da Silva, Claudia Pereira; Navickiene, Sandro

    2010-08-01

    An extraction method based on matrix solid-phase dispersion was developed to determine pirimicarb, methyl parathion, malathion, procymidone, alpha-endosulfan and beta-endosulfan in lettuce using gas chromatography-mass spectrometry. The best results were obtained using 4.0 g of lettuce, 2.0 g of silica as dispersant sorbent, 0.1 g of activated carbon as clean up sorbent and acetonitrile as eluting solvent. The method was validated using lettuce samples fortified with pesticides at six different concentration levels (0.1 to 2.0 mg/kg). Average recoveries (7 replicates) ranged from 50 to 120%, with relative standard deviations between 0.6 and 8.0%. Detection and quantification limits for lettuce ranged from 0.01 to 0.02 mg/kg and 0.04 to 0.10 mg/kg, respectively.

  3. EVALUATION OF SUPERCRITICAL FLUID EXTRACTION FOR ELIMINATING INTERFERENCES DURING MULTIRESIDUE PATRICIDE ANALYSIS. (R825549C011)

    EPA Science Inventory

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  4. Determination of chiral pharmaceuticals and illicit drugs in wastewater and sludge using microwave assisted extraction, solid-phase extraction and chiral liquid chromatography coupled with tandem mass spectrometry.

    PubMed

    Evans, Sian E; Davies, Paul; Lubben, Anneke; Kasprzyk-Hordern, Barbara

    2015-07-02

    This is the first study presenting a multi-residue method allowing for comprehensive analysis of several chiral pharmacologically active compounds (cPACs) including beta-blockers, antidepressants and amphetamines in wastewater and digested sludge at the enantiomeric level. Analysis of both the liquid and solid matrices within wastewater treatment is crucial to being able to carry out mass balance within these systems. The method developed comprises filtration, microwave assisted extraction and solid phase extraction followed by chiral liquid chromatography coupled with tandem mass spectrometry to analyse the enantiomers of 18 compounds within all three matrices. The method was successfully validated for 10 compounds within all three matrices (amphetamine, methamphetamine, MDMA, MDA, venlafaxine, desmethylvenlafaxine, citalopram, metoprolol, propranolol and sotalol), 7 compounds validated for the liquid matrices only (mirtazapine, salbutamol, fluoxetine, desmethylcitalopram, atenolol, ephedrine and pseudoephedrine) and 1 compound (alprenolol) passing the criteria for solid samples only. The method was then applied to wastewater samples; cPACs were found at concentration ranges in liquid matrices of: 1.7 ng L(-1) (metoprolol) - 1321 ng L(-1) (tramadol) in influent,

  5. Development of a multiple-class analytical method based on the use of synthetic matrices for the simultaneous determination of commonly used commercial surfactants in wastewater by liquid chromatography-tandem mass spectrometry.

    PubMed

    Alexandre, Bergé; Barbara, Giroud; Laure, Wiest; Bruno, Domenjoud; Adriana, Gonzalez-Ospina; Emmanuelle, Vulliet

    2016-06-10

    Discharges of surfactants from wastewater treatment plants are often considered as the principal vector of pollution into the environment. The analysis of complex matrices, such as urban wastewater, suspended solids and biological sludge requires careful preparation of the sample to obtain a sensitive, selective and reproducible analysis. A simple, fast, effective and multi-residue method based on the SPE (water) and QuEChERS (solid matrices) approaches using synthetic matrices for validation and quantification, has been developed for the determination of 16 surfactants in wastewater, suspended solids and biological sludge. This work resulted in an innovative method that was validated to detect and assess several classes of surfactants such as quaternary ammonium compounds, betaïns, alkylphenols and their ethoxylated or sulfated derivatives in urban wastewater and solid matrices. The optimised extraction method exhibited recoveries comprised between 83% and 120% for all the tested compounds in the dissolved matrix and between 50% and 109% for particulate matrix. The limits of quantification of all compounds were comprised between 0.1 and 1.0μg/L for dissolved matrix and between 2 and 1000ng/g (dry weight) in particulate matrix. Linearity was assessed for all compounds within the [LOQ-250LOQ] range. Confidence intervals were also computed in real matrices with less than 15% margin of error for all studied surfactants. This work has confirmed, first and foremost, that surfactants are indeed highly concentrated in urban wastewater. As expected, linear alkylbenzene sulfonates were present at significant concentrations (up to 1-2mg/L). In addition, although biological processing results in significant removal of the total pollution, the residual concentrations at output of WWTP remain significant (up to 100μg/L). Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Determination of pesticides in coconut (Cocos nucifera Linn.) water and pulp using modified QuEChERS and LC-MS/MS.

    PubMed

    Ferreira, Jordana Alves; Ferreira, Joana Maria Santos; Talamini, Viviane; Facco, Janice de Fátima; Rizzetti, Tiele Medianeira; Prestes, Osmar Damian; Adaime, Martha Bohrer; Zanella, Renato; Bottoli, Carla Beatriz Grespan

    2016-12-15

    The use of pesticides is directly linked to improvements in productivity and to the preservation of coconut palms. However pesticide analysis is necessary to determine whether pesticide residues in the food products containing coconut are within the maximum residue limits (MRLs), ensuring the quality of these products. This work aimed to develop a method for multiresidue determination of ten pesticides in coconut water and pulp using QuEChERS and LC-MS/MS. The method was effective in terms of selectivity, linearity, matrix effect, accuracy and precision, providing LOD of 3μgkg(-1), LOQ of 10μgkg(-1) and recoveries between 70 and 120% with RSD lower than 20%. The developed method was applied to 36 samples in which residues of carbendazim, carbofuran, cyproconazole and thiabendazole were found below the LOQ in coconut water and pulp. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. ELISA for sulfonamides and its application for screening in water contamination.

    PubMed

    Shelver, Weilin L; Shappell, Nancy W; Franek, Milan; Rubio, Fernando R

    2008-08-13

    Two enzyme-linked immunosorbent assays (ELISAs) were tested for their suitability for detecting sulfonamides in wastewater from various stages in wastewater treatment plants (WWTPs), the river into which the wastewater is discharged, and two swine-rearing facilities. The sulfamethoxazole ELISA cross-reacts with several compounds, achieving detection limits of <0.04 microg/L for sulfamethoxazole (SMX), sulfamethoxypyridine, sulfachloropyridine, and sulfamethoxine, whereas the sulfamethazine (SMZ) ELISA is more compound specific, with a detection limit of <0.03 microg/L. Samples from various stages of wastewater purifications gave 0.6-3.1 microg/L by SMX-ELISA, whereas river samples were approximately 10-fold lower, ranging from below detection to 0.09 microg/L. Swine wastewater samples analyzed by the SMX-ELISA were either at or near detectable limits from one facility, whereas the other facility had concentrations of approximately 0.5 microg/L, although LC-MS/MS did not confirm the presence of SMX. Sulfamethazine ELISA detected no SMZ in either WWTP or river samples. In contrast, wastewater samples from swine facilities analyzed by SMZ-ELISA were found to contain approximately 30 microg/L [piglet (50-100 lb) wastewater] and approximately 7 microg/L (market-weight hog wastewater). Sulfamethazine ELISA analyses of wastewater from another swine facility found concentrations to be near or below detection limits. A solid phase extraction method was used to isolate and concentrate sulfonamides from water samples prior to LC-MS/MS multiresidue confirmatory analysis. The recoveries at 1 microg/L fortification ranged from 42 +/- 4% for SMZ to 88 +/- 4% for SMX ( n = 6). The ELISA results in the WWTPs were confirmed by LC-MS/MS, as sulfonamide multiresidue confirmatory analysis identified SMX, sulfapyridine, and sulfasalazine to be present in the wastewater. Sulfamethazine presence at one swine-rearing facility was also confirmed by LC-MS/MS, demonstrating the usefulness of the ELISA technique as a rapid and high-throughput screening method.

  8. Simultaneous analysis of opioid analgesics and their metabolites in municipal wastewaters and river water by liquid chromatography-tandem mass spectrometry.

    PubMed

    Krizman-Matasic, Ivona; Kostanjevecki, Petra; Ahel, Marijan; Terzic, Senka

    2018-01-19

    Although published literature provides a clear demonstration of widespread occurrence of opioid analgesics (OAs) in the aquatic environment, analytical methods suitable for a systematic study of this pharmaceutical class, which would include a broad spectrum of opioid analgesics and their metabolites, are still missing. In this work, a comprehensive multiresidue method for quantitative analysis of 27 opioid analgesics and their metabolites, including 2 morphine glucuronide conjugates, was developed and validated for three matrices: raw wastewater (RW), secondary effluent (SE) and river water. The method comprised different classes of opioid analgesics, including natural opiates (morphine and codeine), their semi-synthetic derivatives (hydrocodone, hydromorphone, oxycodone, oxymorphone and buprenorphine) as well as fully synthetic opioids such as methadone, fentanyl, sufentanil, propoxyphene and tramadol. The optimized enrichment procedure involved mixed-mode, strong cation-exchange sorbent in combination with a sequential elution procedure. The extracts were analyzed by reversed-phase liquid chromatography using a Synergy Polar column coupled to electrospray ionization tandem mass spectrometry (LC-MS/MS). Accurate quantification of target OAs was achieved using 19 deuterated analogues as surrogate standards. Method accuracies for RW, SE and river water varied in the range from 91 to 126%, 74 to 120% and 75 to 116%, respectively. Careful optimization of the procedure allowed reliable determination of OAs with method quantification limits in the low ng/L range (RW: 0.3-3.5 ng/L; SE: 0.2-1.9 ng/L, river water: 0.1-0.8 ng/L. The developed method was applied for analysis of RW, SE and river water samples from Croatia. The concentrations of individual OAs in municipal wastewater varied in a wide range (from < QL to 859 ng/L) and the most prevalent representatives were tramadol, codeine, morphine and methadone and their derivatives. Elevated concentrations of morphine glucuronides (up to 370 ng/L) found in raw municipal wastewater indicated their importance in the overall morphine mass balance. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Multi-contaminant analysis of organophosphate and halogenated flame retardants in food matrices using ultrasonication and vacuum assisted extraction, multi-stage cleanup and gas chromatography-mass spectrometry.

    PubMed

    Xu, Fuchao; García-Bermejo, Ángel; Malarvannan, Govindan; Gómara, Belén; Neels, Hugo; Covaci, Adrian

    2015-07-03

    A multi-residue analytical method was developed for the determination of a range of flame retardants (FRs), including polybrominated diphenyl ethers (PBDEs), emerging halogenated FRs (EFRs) and organophosphate FRs (PFRs), in food matrices. An ultrasonication and vacuum assisted extraction (UVAE), followed by a multi-stage clean-up procedure, enabled the removal of up to 1g of lipid from 2.5 g of freeze-dried food samples and significantly reduce matrix effects. UVAE achieves a waste factor (WF) of about 10%, while the WFs of classical QuEChERS methods range usually between 50 and 90%. The low WF of UVAE leads to a dramatic improvement in the sensitivity along with saving up to 90% of spiking (internal) standards. Moreover, a two-stage clean-up on Florisil and aminopropyl silica was introduced after UVAE, for an efficient removal of pigments and residual lipids, which led to cleaner extracts than normally achieved by dispersive solid phase extraction (d-SPE). In this way, the extracts could be concentrated to low volumes, e.g. <100 μL and the equivalent matrix concentrations were up to 100g ww/mL. The final analysis of PFRs was performed on GC-EI-MS, while PBDEs and EFRs were measured by GC-ECNI-MS. Validation tests were performed with three food matrices (lean beef, whole chicken egg and salmon filet), obtaining acceptable recoveries (66-135%) with good repeatability (RSD 1-24%, mean 7%). Method LOQs ranged between 0.008 and 0.04 ng/g dw for PBDEs, between 0.08 and 0.20 ng/g dw for EFRs, and between 1.4 and 3.6 ng/g dw for PFRs. The method was further applied to eight types of food samples (including meat, eggs, fish, and seafood) with lipid contents ranging from 0.1 to 22%. Various FRs were detected above MLOQ levels, demonstrating the wide-range applicability of our method. To the best of our knowledge, this is the first method reported for simultaneous analysis of brominated and organophosphate FRs in food matrices. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. QuEChERS, a sample preparation technique that is “catching on”: an up-to-date interview with its inventors

    USDA-ARS?s Scientific Manuscript database

    The technique of QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) is only 7 years old, yet it is revolutionizing the manner in which multiresidue, multiclass pesticide analysis (and perhaps beyond) is performed. Columnist Ron Majors sits down with inventors Steve Lehotay and Michelangelo An...

  11. Rapid semi-quantification of zilpaterol from biological matrices using ASAP and DESI-like MS from a commercial heated electrospray ionization probe

    USDA-ARS?s Scientific Manuscript database

    Quantitation of contaminants in food animal products by regulatory officials is mostly conducted using hyphenated mass spectrometry (MS) technologies. While hyphenated MS approaches can be used for multi-residue sample analysis in an effective manner, it is time consuming, expensive, and labor inten...

  12. Development of a multiresidue method for the determination of endocrine disrupters in fish fillet using gas chromatography-triple quadrupole tandem mass spectrometry.

    PubMed

    Munaretto, Juliana S; Ferronato, Giovana; Ribeiro, Lucila C; Martins, Manoel L; Adaime, Martha B; Zanella, Renato

    2013-11-15

    Endocrine Disrupter Compounds (EDCs) are responsible for alterations in the endocrine system functions. Aquatic organisms are able to accumulate EDCs residues, being the major source of contamination for top predators and human consumers. This study aimed to develop and validate a method for the determination of 40 EDCs in fish fillet using modified QuEChERS and Gas Chromatography coupled with Mass Spectrometry in tandem (GC-MS/MS). A factorial design was used to optimize the extraction procedure. Method validation presented recoveries from 70.1% to 120.0% with RSD<20% and method limit of detection ranged from 0.3 to 7.5 µg kg(-1), showing good accuracy and precision. This method was successfully applied to the analysis of fish fillet from different species and residues of bisphenol A, chlorpyrifos and bifenthrin were detected. The proposed method proved to be effective for the determination of EDCs in fish fillet at very low concentration levels. © 2013 Elsevier B.V. All rights reserved.

  13. Strategies to avoid false negative findings in residue analysis using liquid chromatography coupled to time-of-flight mass spectrometry.

    PubMed

    Kaufmann, Anton; Butcher, Patrick

    2006-01-01

    Liquid chromatography coupled to orthogonal acceleration time-of-flight mass spectrometry (LC/TOF) provides an attractive alternative to liquid chromatography coupled to triple quadrupole mass spectrometry (LC/MS/MS) in the field of multiresidue analysis. The sensitivity and selectivity of LC/TOF approach those of LC/MS/MS. TOF provides accurate mass information and a significantly higher mass resolution than quadrupole analyzers. The available mass resolution of commercial TOF instruments ranging from 10 000 to 18 000 full width at half maximum (FWHM) is not, however, sufficient to completely exclude the problem of isobaric interferences (co-elution of analyte ions with matrix compounds of very similar mass). Due to the required data storage capacity, TOF raw data is commonly centroided before being electronically stored. However, centroiding can lead to a loss of data quality. The co-elution of a low intensity analyte peak with an isobaric, high intensity matrix compound can cause problems. Some centroiding algorithms might not be capable of deconvoluting such partially merged signals, leading to incorrect centroids.Co-elution of isobaric compounds has been deliberately simulated by injecting diluted binary mixtures of isobaric model substances at various relative intensities. Depending on the mass differences between the two isobaric compounds and the resolution provided by the TOF instrument, significant deviations in exact mass measurements and signal intensities were observed. The extraction of a reconstructed ion chromatogram based on very narrow mass windows can even result in the complete loss of the analyte signal. Guidelines have been proposed to avoid such problems. The use of sub-2 microm HPLC packing materials is recommended to improve chromatographic resolution and to reduce the risk of co-elution. The width of the extraction mass windows for reconstructed ion chromatograms should be defined according to the resolution of the TOF instrument. Alternative approaches include the spiking of the sample with appropriate analyte concentrations. Furthermore, enhanced software, capable of deconvoluting partially merged mass peaks, may become available. Copyright (c) 2006 John Wiley & Sons, Ltd.

  14. Determination of formetanate hydrochloride in fruit samples using liquid chromatography-mass selective detection or -tandem mass spectrometry.

    PubMed

    Podhorniak, Lynda V; Kamel, Alaa; Rains, Diane M

    2010-05-26

    A rapid multiresidue method that captures residues of the insecticide formetanate hydrochloride (FHCl) in selected fruits is described. The method was used to provide residue data for dietary exposure determinations of FHCl. Using an acetonitrile extraction with a dispersive cleanup based on AOAC International method 2007.01, also known as QuEChERS, which was further modified and streamlined, thousands of samples were successfully analyzed for FHCl residues. FHCl levels were determined both by liquid chromatography-single-stage mass spectrometry (LC-MS) and ultraperformance liquid chromatography (UPLC)-tandem mass spectrometry (LC-MS/MS). The target limit of detection (LOD) and the limit of quantitation (LOQ) achieved for FHCl were 3.33 and 10 ng/g, respectively, with LC-MS and 0.1 and 0.3 ng/g, respectively, with LC-MS/MS. Recoveries at these previously unpublished levels ranged from 95 to 109%. A set of 20-40 samples can be prepared in one working day by two chemists.

  15. Simplified RP-HPLC method for multi-residue analysis of abamectin, emamectin benzoate and ivermectin in rice.

    PubMed

    Xie, Xianchuan; Gong, Shu; Wang, Xiaorong; Wu, Yinxing; Zhao, Li

    2011-01-01

    A rapid, reliable and sensitive reverse-phase high-performance liquid chromatography method with fluorescence detection (RP-FLD-HPLC) was developed and validated for simultaneous analysis of the abamectin (ABA), emamectin (EMA) benzoate and ivermectin (IVM) residues in rice. After extraction with acetonitrile/water (2 : 1) with sonication, the avermectin (AVMs) residues were directly derivatised by N-methylimidazole (N-NMIM) and trifluoroacetic anhydride (TFAA) and then analysed on RP-FLD-HPLC. A good linear relationship (r(2 )> 0.99) was obtained for three AVMs ranging from 0.01 to 5 microg ml(-1), i.e. 0.01-5.0 microg g(-1) in rice matrix. The limit of detection (LOD) and the limit of quantification (LOQ) were between 0.001 and 0.002 microg g(-1) and between 0.004 and 0.006 microg g(-1), respectively. Recoveries were from 81.9% to 105.4% and precision less than 12.4%. The proposed method was successfully applied to routine analysis of the AVMs residues in rice.

  16. Quantitative mass spectrometry methods for pharmaceutical analysis

    PubMed Central

    Loos, Glenn; Van Schepdael, Ann

    2016-01-01

    Quantitative pharmaceutical analysis is nowadays frequently executed using mass spectrometry. Electrospray ionization coupled to a (hybrid) triple quadrupole mass spectrometer is generally used in combination with solid-phase extraction and liquid chromatography. Furthermore, isotopically labelled standards are often used to correct for ion suppression. The challenges in producing sensitive but reliable quantitative data depend on the instrumentation, sample preparation and hyphenated techniques. In this contribution, different approaches to enhance the ionization efficiencies using modified source geometries and improved ion guidance are provided. Furthermore, possibilities to minimize, assess and correct for matrix interferences caused by co-eluting substances are described. With the focus on pharmaceuticals in the environment and bioanalysis, different separation techniques, trends in liquid chromatography and sample preparation methods to minimize matrix effects and increase sensitivity are discussed. Although highly sensitive methods are generally aimed for to provide automated multi-residue analysis, (less sensitive) miniaturized set-ups have a great potential due to their ability for in-field usage. This article is part of the themed issue ‘Quantitative mass spectrometry’. PMID:27644982

  17. Quinolones and tetracyclines in aquaculture fish by a simple and rapid LC-MS/MS method.

    PubMed

    Guidi, Letícia Rocha; Santos, Flávio Alves; Ribeiro, Ana Cláudia S R; Fernandes, Christian; Silva, Luiza H M; Gloria, Maria Beatriz A

    2018-04-15

    The determination of antimicrobials in aquaculture fish is important to ensure food safety. Therefore, simple and fast multiresidue methods are needed. A liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of 14 antimicrobials (quinolones and tetracyclines) in fish. Antimicrobials were extracted with trichloroacetic acid and chromatographic separation was achieved with a C18 column and gradient elution (water and acetonitrile). The method was validated (Decision 2002/657/EC) and it was fit for the purpose. Linearities were established in the matrix and the coefficients of determination were ≥0.98. The method was applied to Nile tilapia and rainbow trout (n = 29) and 14% of them contained enrofloxacin at levels above the limit of quantification (12.53-19.01 µg.kg -1 ) but below the maximum residue limit (100 µg.kg -1 ). Even though prohibited in Brazil and other countries, this antimicrobial reached fish. Measures are needed to ascertain the source of this compound to warrant human safety. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Multiresidue Screening Method for Detection of Benzimidazoles and their Metabolites in Liver and Muscle by High-Performance Liquid Chromatography: Method Development and Validation According to Commission Decision 2002/657/EC

    PubMed Central

    Prearo, Marino; Stella, Paola; Ostorero, Federica; Abete, Maria Cesarina

    2014-01-01

    The use of veterinary drugs may cause the presence of residues in food of animal origin if appropriate withdrawal periods are not respected. A high-performance liquid chromatography (HPLC) method has been developed for the simultaneous detection of 11 benzimidazole residues, including metabolites – albendazole, albendazole sulphoxide, albendazole sulphone, fenbendazole, fenbendazole sulphoxide (oxfendazole), fenbendazole sulphone, flubendazole, mebendazole, oxibendazole, thiabendazole, 5-hydroxythiabendazole – in bovine, ovine, equine, swine, rabbit and poultry liver and in bovine, swine and fish muscle. After extraction with a dicloromethane/acetonitrile solution (35/65 v/v) containing 5% ammonium hydroxide, the solvent was evaporated to dryness, the residue was dissolved in HCl 0.1 M, defatted with hexane, purified on a strong cation exchange solid-phase extraction cartridge and analysed in HPLC with diode array and fluorescence detectors. The method was validated as screening qualitative method evaluating, according to Commission Decision 2002/657/EC criteria, specificity, CCβ and β error at cut off level of 25 μg/kg and ruggedness. PMID:27800310

  19. A multi-residue method for pesticides analysis in green coffee beans using gas chromatography-negative chemical ionization mass spectrometry in selective ion monitoring mode.

    PubMed

    Pizzutti, Ionara R; de Kok, Andre; Dickow Cardoso, Carmem; Reichert, Bárbara; de Kroon, Marijke; Wind, Wouter; Weber Righi, Laís; Caiel da Silva, Rosselei

    2012-08-17

    In this study, a new gas chromatography-mass spectrometry (GC-MS) method, using the very selective negative chemical ionization (NCI) mode, was developed and applied in combination with a modified acetonitrile-based extraction method (QuEChERS) for the analysis of a large number of pesticide residues (51 pesticides, including isomers and degradation products) in green coffee beans. A previously developed integrated sample homogenization and extraction method for both pesticides and mycotoxins analysis was used. An homogeneous slurry of green milled coffee beans and water (ratio 1:4, w/w) was prepared and extracted with acetonitrile/acetic acid (1%), followed by magnesium sulfate addition for phase separation. Aliquots from this extract could be used directly for LC-MS/MS analysis of mycotoxins and LC-amenable pesticides. For GC-MS analysis, a further clean-up was necessary. C18- and PSA-bonded silica were tested as dispersive solid-phase extraction (d-SPE) sorbents, separate and as a mixture, and the best results were obtained using C18-bonded silica. For the optimal sensitivity and selectivity, GC-MS detection in the NCI-selected ion monitoring (SIM) mode had to be used to allow the fast analysis of the difficult coffee bean matrix. The validation was performed by analyzing recovery samples at three different spike concentrations, 10, 20 and 50 μg kg(-1), with 6 replicates (n=6) at each concentration. Linearity (r(2)) of calibration curves, estimated instrument and method limits of detection and limits of quantification (LOD(i), LOD(m), LOQ(i) and LOQ(m), respectively), accuracy (as recovery %), precision (as RSD%) and matrix effects (%) were determined for each individual pesticide. From the 51 analytes (42 parent pesticides, 4 isomers and 5 degradation products) determined by GC-MS (NCI-SIM), approximately 76% showed average recoveries between 70-120% and 75% and RSD ≤ 20% at the lowest spike concentration of 10 μg kg(-1), the target method LOQ. For the spike concentrations of 20 and 50 μg kg(-1), the recoveries and RSDs were even better. The validated LOQ(m) was 10, 20 and 50 μg kg(-1) for respectively 33, 3 and 6 of the analytes studied. For five compounds, the European Union method performance requirements for the validation of a quantitative method (average recoveries between 70-120% and repeatability RSD ≤ 20%) were not achieved and 4 problematic pesticides (captan, captafol, folpet and dicofol) could not be detected as their parent compound, but only via their degradation products. Although the matrix effect (matrix-enhanced detector response) was high for all pesticides studied, the matrix interference was minimal, due to the high selectivity obtained with the GC-NCI-MS detection. Matrix-matched calibration for applying the method in routine analysis is recommended for reliable quantitative results. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Multicore Magnetic Nanoparticles Coated with Oligomeric Micelles: Characterization and Potential for the Extraction of Contaminants over a Wide Polarity Range.

    PubMed

    Naous, Mohamed; García-Gómez, Diego; López-Jiménez, Francisco José; Bouanani, Farida; Lunar, María Loreto; Rubio, Soledad

    2017-01-17

    Oligomeric micelles from sodium undecylenate (oSUD) were chemisorbed to magnetic iron oxide nanoparticles (MNPs) through a single-step synthetic route involving the simultaneous nanoparticle formation and functionalization in an aqueous medium. The resulting spherical nanoparticles (MNPs-oSUD) consisted of a concatenation of iron oxide cores, with an average size of 7.7 nm, bound by oSUD micelles (particle average diameter of ca. 200 nm). Micellar coverage was ∼50% of the MNP-oSUD (by weight) and offered multiple retention mechanisms (e.g., dispersion, hydrogen bonding, polar, and ionic) for solute solubilization while keeping it intact during analyte elution. The high density of micelles and variety of interactions provided by this sorbent rendered it highly efficient for the extraction of aromatic amines in a wide polarity range (log K ow values from -0.80 to 4.05) from textiles, urine, and wastewater. Extraction took 5 min, no cleanup or evaporation of the extracts was needed and the method, based on LC-MS/MS quantitation, proved matrix-independent. Recoveries for 17 aromatic amines in samples were in the range of 93%-123% while those with negative log K ow values were in the range of 69%-87%. Detection limits for aromatic amines in textiles (0.007-2 mg kg -1 ) were well below the limits legislated by the European Union (EU) (30 mg kg -1 ) and those in urine and wastewater (0.004-1.5 μg L -1 ) were at the level usually found in real-world applications. All the analyzed samples were positive in aromatic amines. The easy synthesis and excellent extraction properties of MNPs-oSUD anticipate their high potential not only for multiresidue analysis but also in other fields such as water remediation.

  1. Comparison of three different poly(dimethylsiloxane)-divinylbenzene fibres for the analysis of pesticide multiresidues in water samples: structure and efficiency.

    PubMed

    Gonçalves, C; Alpendurada, M F

    2002-07-19

    Despite the continuing development of SPME (solid-phase microextraction) fibre coatings, their selection presents some difficulties for analysts in choosing the appropriate fibre for a certain application. There are two distinct types of SPME coatings available commercially. The most widely used are poly(dimethylsiloxane) (PDMS) and poly(acrylate) (PA). Supelco has developed new mixed phases consisting of porous polymer particles, either poly(divinylbenzene) (DVB) or Carboxen suspended in a matrix of PDMS or Carbowax for extracting analytes via adsorption. In addition to the nature of the extracting phase, the thickness of the polymeric film must be taken into account and, surprisingly, the construction of the fibres when apparently they bear the same coating, as it is the case of the three PDMS-DVB fibres available. Other fibre structure properties not well explored were identified and must be taken into consideration. To elucidate their extraction efficiency, three PDMS-DVB fibres, namely 60 microm for HPLC use, 65 microm for GC use and 65 microm StableFlex for GC use, were compared with regard to the extraction of 36 compounds included in four pesticide groups. The first was particularly suited for the extraction of organophosphorus pesticides and triazines whereas the StableFlex exhibited advantages in the analysis of organochlorine pesticides and pyrethroids. An explanation for the extraction differences is suggested based on the different structure of the fibres. Detection limits in the range of 1-10 ng/l for organochlorine pesticides, 1-30 ng/l for organophosphorus pesticides, 8-50 ng/l for triazines and 10-20 ng/l for pyrethroids were attained in a method using the 60 microm PDMS-DVB fibre. The fibre maintains its performance at well above 100 extractions with between-day precision below 10%.

  2. Determination of seven pyrethroids and six pyrethrins in water by liquid chromatography/mass spectrometry

    NASA Astrophysics Data System (ADS)

    ccanccapa, alexander; Masia, Ana; Pico, Yolanda

    2016-04-01

    Pyrethroids are the synthetic analogues of pyrethrins which were developed as pesticides from the extracts of dried and powdered flower heads of Chrysanthemum cinerariaefolium. They are increasingly used in agriculture due to their broad biological activity and slow development of pest resistance. Contamination of fresh-water ecosystems appears either because of the direct discharge of industrial and agricultural effluents or as a result of effluents from sewage treatment works; residues can thus accumulate in the surrounding biosphere [1, 2]. These substances, mostly determined by gas chromatography mass spectrometry (GC-MS) can be difficult to analyse due to their volatility and degradability. The purpose of this study is, as an alternative, to develop a fast and sensitive multi-residue method for the target analysis of 7 pyrethroids and the 6 natural pyrethrins currently used in water samples by liquid chromatography tandem mass spectrometry (LC-MS/MS). The compounds included in the study were acrinathrin, etofenprox, cyfluthrin, esfenvalerate, cyhalothrin, cypermethrin and flumethrin as pyrethroids and a commercial mix of pyrethrins containing Cinerin I, Jasmolin I, pyrethrin I, cinerin II, jasmolin II, pyrethrins II in different percentages. As a preliminary step, the ionization and fragmentation of the compounds were optimized injecting individual solutions of each analyte at 10 ppm in the system, using a gradient elution profile of water-methanol both with 10 mM ammonium formate. The ESI conditions were: capillary voltage 4000 V, nebulizer15 psi, source temperature 300◦C and gas flow 10 L min-1. [M+H]+, [M+Na]+ ,[M+NH3]+ ,[M+NH4+]+ were tested as precursor ions. The most intense signal was for ammonium adduct for all compounds. The optimal fragmentor range for product ions were between 20 to 80 ev and the collision energy ranged between 5 to 86 ev. The efficiency of the method was tested in water samples from Turia River without any known exposure to pyrethroids. At least three of the seven pyrethroids were detected.

  3. Pesticide analysis in coffee leaves using a quick, easy, cheap, effective, rugged and safe approach and liquid chromatography tandem mass spectrometry: Optimization of the clean-up step.

    PubMed

    Trevisan, Maria Teresa Salles; Owen, Robert Wyn; Calatayud-Vernich, Pau; Breuer, Andrea; Picó, Yolanda

    2017-08-25

    An analytical method using a quick, easy, cheap, effective, rugged and safe (QuEChERS) procedure for multi-residue determination of 52 pesticides in coffee leaf extractshas been developed and validated according to SANTE/11945/2015 guidelines. Different sorbent combinations for dispersive solid phase extraction (d-SPE) clean-up as well as dispersive liquid-liquid microextraction (DLLME) were tested. The relative standard deviations (RSDs) for the recovery of 87-94% of pesticides added to coffee leaf extracts,was ≤20% for samples spiked at concentrations up to 50ng*g -1 depending on the clean-up procedures. However, samples spiked with a 100ng*g -1 pesticide mixture gave RSDs>20% for most pesticides when d-SPE was carried out adding Supelclean ENVI-Carb 120/400. To explain this fact,the secondary metabolic profile was analyzed in all the extraction and clean-up procedures. Only in the clean-up procedure with the addition of Supel QuE Z-Sep+, does caffeine show a constant adsorption between blank and spiked samples. In other clean-up procedures, the amount of caffeine was higher in those samples spiked with pesticides. This indicates competition between caffeine and pesticides for adsorption to the sorbent. Addition of Supel QuE Z-Sep+ to the procedure revealed only a 32% matrix effect, whereas using PSA+ C18 the matrix effect was close to 97%. The process efficiency is up to 54% with the addition of Supel QuE Z-Sep+ and just up to 7% for the other clean-up procedures. The method was successfully tested in coffee leaves from different types of cultivars. Pesticides were not detected in organic coffee leaf extracts, but thiametoxan was clearly detected in 50% of coffee leaf extracts harvested from coffee trees grown under traditional conditions as determined by UHPLC-TOFMSLC/QqTOF-MS/MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Multi-residue determination of 171 pesticides in cowpea using modified QuEChERS method with multi-walled carbon nanotubes as reversed-dispersive solid-phase extraction materials.

    PubMed

    Han, Yongtao; Song, Le; Zou, Nan; Chen, Ronghua; Qin, Yuhong; Pan, Canping

    2016-09-15

    A rapid and sensitive method for the determination of 171 pesticides in cowpea was developed using multi-walled carbon nanotubes (MWCNTs) as reversed-dispersive solid-phase (r-DSPE) extraction materials. The clean-up performance of MWCNTs was proved to be obviously superior to PSA and GCB. This method was validated on cowpea spiked at 0.01 and 0.1mgkg(-1) with five replicates. The mean recoveries for 169 pesticides ranged from 74% to 129% with relative standard deviations (RSDs) (n=5) lower than 16.4%, except diflufenican and quizalofop-ethyl. Good linearity for all pesticides was obtained with the calibration curve coefficients (R(2)) larger than 0.9970. The limit of detection (LODs) and limit of quantification (LOQs) for the 171 pesticides ranged from 0.001 to 0.003mgkg(-1) and from 0.002 to 0.009mgkg(-1), respectively. The method was demonstrated to be reliable and sensitive for the routine monitoring of the 171 pesticides in cowpea samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Multiresidue chromatographic method for the determination of macrolide residues in muscle by high-performance liquid chromatography with UV detection.

    PubMed

    Juhel-Gaugain, M; Anger, B; Laurentie, M

    1999-01-01

    A high-performance liquid chromatographic (HPLC) method for the simultaneous determination of tilmicosin, tylosin, spiramycin, and its major metabolite neospiramycin was developed that is suitable for porcine, bovine, and poultry muscles. Macrolide residues were extracted from muscle with acetonitrile, fat was removed by liquid-liquid extraction with isooctane, and the extract was then cleaned on Bond Elut C18 cartridges. The HPLC separation was performed on an Inertsil ODS3 C18 column (150 x 4 mm) with 0.05% trifluoroacetic acid-acetonitrile in a gradient mode. Two different chromatographic gradients were used for tilmicosin-tylosin and spiramycin-neospiramycin, and the detection wavelengths were 287 and 232 nm, respectively. The method was validated from 1/2 the maximum residue limit (MRL) to 4 times the MRL with pork muscle samples. Mean recoveries were 60, 63.5, 51, and 42% for tilmicosin, tylosin, spiramycin, and neospiramycin, respectively. The detection limits are 15 micrograms/kg for tilmicosin and tylosin, 30 micrograms/kg for spiramycin, and 25 micrograms/kg for neospiramycin. Linearity, precision, and accuracy of the method were also tested.

  6. Monitoring of pesticide residues in vegetarian diet.

    PubMed

    Kumari, Beena; Kathpal, T S

    2009-04-01

    Samples (28) of complete vegetarian diet consumed from morning till night i.e. tea, milk, breakfast, lunch, snacks, dinner, sweet dish etc. were collected from homes, hostels and hotels periodically from Hisar and analysed for detecting the residues of organochlorine, synthetic pyrethriod, organophosphate and carbamate insecticides. The estimation was carried out by using multi-residue analytical technique employing gas chromatograph (GC)-electron capture detector and GC-nitrogen phosphorous detector systems equipped with capillary columns. The whole diet sample was macerated in a mixer grinder and a representative sample in duplicate was analyzed for residues keeping the average daily diet of an adult to be 1,300 g. On comparing the data, it was found that actual daily intake (microgram/person/day) of lindane in two and endosulfan in four samples exceeded the acceptable daily intake. Residues of other pesticides in all the diet samples were lower than the acceptable daily intake (ADI) of the respective pesticides. The study concluded that although all the diet samples were found contaminated with one or the other pesticide, the actual daily intake of only a few pesticides was higher than their respective ADI. More extensive study covering other localities of Haryana has been suggested to know the overall scenario of contamination of vegetarian diet.

  7. Assessmet of temporal distribution of pesticide residues in vineyard soils of La Rioja (Spain)

    NASA Astrophysics Data System (ADS)

    Pose Juan, Eva; Herrero Hernandez, Eliseo; Soledad Andrades, Maria; Rodriguez Cruz, Maria Sonia; Sanchez Martin, Maria Jesus

    2013-04-01

    The use and application of pesticides in vineyard is a common practice, which is important to prevent pest and diseases and improve the crop health and production, but on the other hand it could involve a potential risk for humans and the environment. For this reason, it is important to develop and validate a simple and fast multiresidue method to determine the presence of these compounds in soils. La Rioja region (Spain) is one of the most important wine-growing regions in Spain, which also entails that could be an important area of pesticide pollution. The objective of this work is to assess the temporal distribution of the possible pesticide pollution in soils from different areas of La Rioja (Spain). The pesticides selected in this study included fungicides (metalaxyl, and its metabolite CGA62826, pyrimethanil, tebuconazole, myclobutanil, kresoxim-methyl, triadimenol and flutriafol); herbicides (fluometuron, terbuthylazine and its metabolites desethylterbuthylazine and hydroxyterbuthylazine, lenacil, ethofumesate and acetochlor) and insecticides (methoxyfenozide and pirimicarb). The pesticide residues were evaluated by two analytical techniques, gas chromatography and liquid chromatography (GC-MS and LC-MS). The extraction procedure of pesticides from soils was optimized using two soil samples (blank soils) with different texture and characteristics collected from areas without pesticide application. Recoveries were studied in soil samples fortified with all pesticides at two levels of concentrations (the agronomic dose, 0.1 mg kg-1, and ten times this dose, 1 mg kg-1). Different extraction solvents were tested. The best results were obtained with methanol:acetone (50:50) mixture or methanol:CaCl2 0.01 M (50:50) mixture for hydroxyterbuthylazine and CGA62826. The accuracy (average recovery) and precision (reproducibility and repeatability) of the method were assessed using six replicates and the limits of detection (LODs) and quantification (LOQs) were estimated. Recoveries were above 70% for all pesticides. Good linear relationships of the calibration curves (0.01-1 μg mL-1) were obtained for all the compounds by the two analytical methods with regression coefficients (r2) higher than 0.99 in the range of concentrations studied. Detection limits were < 2 ng g-1 for pesticides studied. After the development and validation of an analytical method, the study of the temporal variability of the pesticide pollution in different periods of time (September 2011, and March, June and October 2012) were performed. Herbicide residues were found in most of the soils and an increment in concentrations of these compounds and in the number of positive samples were detected in samples collected in March 2012 in relation to those collected in September 2011. This increase in the number of positive samples was of 30 % for terbuthylazine. Fungicide residues were detected in greater concentrations in samples collected in September. Both behaviours may be related with the time of application of both types of compounds. Herbicides are commonly applied in March-April and fungicides are usually applied in summer, when different grapevine diseases like botrytis or mildiu commonly appear. Moreover, new pesticide residues were detected in March 2012, which were not detected in September 2011 in any soil sample. Further analysis of results is in course.

  8. Effect of food processing on degradation of hexachlorocyclohexane and its isomers in milk

    PubMed Central

    Singh, Sujatha; Nelapati, Krishnaiah

    2017-01-01

    Aim: To study the effect of different food processing techniques on the degradation of organochlorine compounds (α, β, ɣ and δ hexachlorocyclohexane isomers (HCH)) residues in both natural and fortified samples of milk. Materials and Methods: Raw milk samples are collected from the local areas of Hyderabad, India. Naturally and fortified milk samples (HCH) were subjected to various food processing techniques, pasteurization (63ºC for ½ h), sterilization (121ºC for 15 min) and boiling for 5 min and analyzed by gas chromatography with electron capture detector using quick, easy, cheap, effective, rugged and safe method for multiresidue analysis of pesticides in milk with slight modification. Results: The final mean residual concentration of pesticide in milk after heat processing and percentage of degradation were calculated with respective treatments. Conclusion: Heat treatments are highly effective on reduction of mean residual concentration of HCH in milk. In which Sterilization and boiling proved to be more effective in degradation of HCH isomers. PMID:28435187

  9. Simultaneous determination of fluoroquinolones in environmental water by liquid chromatography-tandem mass spectrometry with direct injection: A green approach.

    PubMed

    Denadai, Marina; Cass, Quezia Bezerra

    2015-10-30

    This work describes an on-line multi-residue method for simultaneous quantification of ciprofloxacin, enrofloxacin, gemifloxacin, moxifloxacin, norfloxacin and ofloxacin in superficial and wastewater samples. For that, an octyl restricted-access media bovine serum albumin column (RAM-BSA C8) was used for sample clean-up, enrichment and analysis with quantitation carried out by tandem mass spectrometry. For water samples volumes of only 500μL the method provided good selectivity, extraction efficiency, accuracy, and precision with quantification limits in the order of 20-150ngL(-1). Out of the six fluoroquinolones only ciprofloxacin (195ngL(-1)) and norfloxacin (270ngL(-1)) were quantified in an influent sample of the wastewater treatment plant (WWTP) of São Carlos (SP, Brazil). None were found in the superficial water samples analyzed. The capability of injecting native sample in an automated mode provides high productivity and represents a greener approach in environmental sample analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Multidetection of antibiotics in liver tissue by ultra-high-pressure-liquid-chromatography-tandem mass spectrometry.

    PubMed

    Freitas, Andreia; Barbosa, Jorge; Ramos, Fernando

    2015-01-22

    A multiresidue quantitative screening method covering 39 antibiotics from 7 different families by ultra-high-pressure-liquid-chromatography-tandem mass spectrometry (UHPLC-MS/MS) is described. Sulfonamides, trimethoprim, tetracyclines, macrolides, quinolones, penicillins and chloramphenicol are simultaneously detected in liver tissue. A simple sample treatment method consisting of extraction with a mixture of acetonitrile and ethylenediaminetetraacetic acid (EDTA) followed by solid-phase extraction (SPE) with a hydrophilic-lipophilic balanced (HLB) cartridge was developed. The methodology was validated, in accordance with Decision 2002/657/EC, by evaluating the following required parameters: decision limit (CCα), detection capability (CCβ), specificity, repeatability and reproducibility. The precision, in terms of the relative standard deviation, was under 22% for all of the compounds, and the recoveries were between 80% and 110%. The CCα and CCβ were determined according to the maximum residue limit (MRL) or the minimum required performance limit (MRPL), when established. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. On-line solid phase extraction-liquid chromatography-tandem mass spectrometry for insect repellent residue analysis in surface waters using atmospheric pressure photoionization.

    PubMed

    Molins-Delgado, Daniel; García-Sillero, Daniel; Díaz-Cruz, M Silvia; Barceló, Damià

    2018-04-06

    Insect repellents (IRs) are a group of organic chemicals whose function is to prevent the ability of insects of landing in a surface. These compounds have been found in the environment and may pose a risk to non-target organisms. In this study, an on-line solid phase extraction - high performance liquid chromatography-tandem mass spectrometry multiresidue method was developed using an atmospheric photoionization source (SPE-HPLC-(APPI)-MS/MS). The use of the APPI as an alternative ionization technique to electrospray (ESI) and atmospheric pressure chemical ionization (APCI) allowed expanding the range of analytical techniques suitable for the analysis of IRs, so far relied in gas chromatography. High sensitivity and precision was reached with method limits of quantification between 0.2 and 4.6 ng l -1 and interday and intraday precision equal or below 15%. The validated method was applied to the study of surface water samples from three European river basins with different flow regime (Adige River in Italy, Sava River in the Balkans, and Evrotas River in Greece). The results showed that two IRs (DEET and Bayrepel) were ubiquitous in the Sava and Evrotas basins, reaching concentrations as high as 105 μg l -1 of Bayrepel in the Sava River, and 5 μg l -1 of DEET in the Evrotas River. Densely populated areas and effluent waste waters are pointed out as the responsible for this pollution. In the alpine river Adige, only three samples showed low levels of IRs (6.01-37.8 ng l -1 ). The concentrations measured were used to perform an environmental risk assessment based on the hazard quotients (HQs) estimation approach by using the chronic and acute eco-toxicity data available. The results revealed that despite the high frequency and eventually high concentrations of these IRs determined in the three basins, only few sites were at risk, with 1 < HQs < 3.3. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  12. Stir bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry: an effective tool for determining persistent organic pollutants and nonylphenol in coastal waters in compliance with existing Directives.

    PubMed

    Sánchez-Avila, Juan; Quintana, Jordi; Ventura, Francesc; Tauler, Romà; Duarte, Carlos M; Lacorte, Silvia

    2010-01-01

    A multi-residual method based on stir bar sorptive extraction coupled with thermal desorption-gas chromatography-mass spectrometry (SBSE-TD-GC-MS) has been developed to measure 49 organic pollutants (organochlorine pesticides, polycyclic aromatic hydrocarbons, polychlorinated biphenyls, polybrominated diphenyl ethers and nonylphenol) in seawater. Using 100ml of water, the method exhibited good linearity, with recoveries between 86% and 118% and relative standard deviation between 2% and 24% for almost all compounds. The method was applied to determine target contaminants in Catalonian seawater, including coastal areas, ports and desalination plant feed water. Overall individual compound levels oscillated between 0.16 and 597 ng l(-1); PAHs and nonylpenol were the compounds found at the highest concentrations. The method provided LODs between 0.011 and 2.5 ng l(-1), lower than the Environmental Quality Standards (EQS) fixed by Directive 2008/105/EC. In compliance with the directive, this method can be used as a tool to survey target compounds and is aimed at protecting coastal ecosystems from chemical pollution. Copyright 2009 Elsevier Ltd. All rights reserved.

  13. Study of matrix effects on the direct trace analysis of acidic pesticides in water using various liquid chromatographic modes coupled to tandem mass spectrometric detection.

    PubMed

    Dijkman, E; Mooibroek, D; Hoogerbrugge, R; Hogendoorn, E; Sancho, J V; Pozo, O; Hernández, F

    2001-08-10

    This study investigated the effects of matrix interferences on the analytical performance of a triple quadrupole mass spectrometric (MS-MS) detector coupled to various reversed-phase liquid chromatographic (LC) modes for the on-line determination of various types of acidic herbicides in water using external calibration for quantification of the analytes tested at a level of 0.4 microg/l. The LC modes included (i) a single-column configuration (LC), (ii) precolumn switching (PC-LC) and (iii) coupled-column LC (LC-LC). As regards detection, electrospray (ESI) and atmospheric pressure chemical ionization (APCI) in both positive (PI) and negative (NI) ionization modes were examined. Salinity and dissolved organic carbon (DOC) were selected as interferences to study matrix effects in this type of analysis. Therefore, Milli-Q and tap water samples both fortified with 12 mg/l DOC and spiked with sulfometuron-methyl, bentazone, bromoxynil, 2-methyl-4-chlorophenoxyacetic acid, and 2-methyl-4-chlorophenoxypropionic acid at a level of about 0.4 microg/l were analyzed with the various LC-MS approaches. Direct sample injection was performed with volumes of 0.25 ml or 2.0 ml on a column of 2.1 mm I.D. or 4.6 mm I.D. for the ESI and APCI modes, respectively. The recovery data were used to compare and evaluate the analytical performance of the various LC approaches. As regards matrix effects, the salinity provided a dramatic decrease in response for early eluting analytes (k value of about 1) when using the LC mode. Both PC-LC and LC-LC efficiently eliminated this problem. The high DOC content hardly effected the responses of analytes in the ESI mode, while in most cases the responses increased when using APCI-MS-MS detection. Of all the tested configurations, LC-LC-ESI-MS-MS with the column combination Discovery C18/ABZ+ was the most favorable as regards elimination of matrix effects and provided reliable quantification of all compounds using external calibration at the tested low level. The major observed effects were verified with statistical evaluation of the data employing backwards ordinary least-square regression. All tested column-switching modes hyphenated to ESI- or APCI-MS-MS allowed the on-line multi-residue analysis of acidic pesticides in the reference water down to a level of 0.1 microg/l in less than 10 min, emphasizing the feasibility of such an approach in this field of analysis.

  14. Multi-residue analysis method for analysis of pharmaceuticals using liquid chromatography-time of flight/mass spectrometry (LC-TOF/MS) in water sample

    NASA Astrophysics Data System (ADS)

    Al-Qaim, Fouad Fadhil; Abdullah, Md Pauzi; Othman, Mohamed Rozali

    2013-11-01

    In this work, a developed method using solid - phase extraction (SPE) followed by liquid chromatography - time of flight mass spectrometry (LC-ESI-TOF/MS) was developed and validated for quantification and confirmation of eleven pharmaceuticals with different therapeutic classes in water samples, Malaysia. These compounds are caffeine (CAF), prazosin (PRZ), enalapril (ENL), carbamazepine (CBZ), nifedipine (NFD), levonorgestrel (LNG), simvastatin (SMV), hydrochlorothiazide (HYD), gliclazide (GLIC), diclofenac-Na (DIC-Na) and mefenamic acid (MEF). LC was performed on a Dionex Ultimate 3000/LC 09115047 (USA) system. Chromatography was performed on a Thermo Scientific C18 (250 mm × 2.1 mm, i.d.: 5μm) column. Several parameters were optimised such as; mobile phase, gradient elution, collision energy and solvent elution for extraction of compounds from water. The recoveries obtained ranged from 30-148 % in river water. Five pharmaceutical compounds were detected in the surface water samples: caffeine, prazosin, enalpril, diclofenac-Na and mefenamic acid. The developed method is precise and accepted recoveries were got. In addition, this method is suitable to identify and quantify trace concentrations of pharmaceuticals in surface water.

  15. Methodology Development in Directed Evolution: Exploring Options when Applying Triple-Code Saturation Mutagenesis.

    PubMed

    Qu, Ge; Lonsdale, Richard; Yao, Peiyuan; Li, Guangyue; Liu, Beibei; Reetz, Manfred T; Sun, Zhoutong

    2018-02-02

    Directed evolution of stereo- or regioselective enzymes as catalysts in asymmetric transformations is of particular interest in organic synthesis. Upon evolving these biocatalysts, screening is the bottleneck. To beat the numbers problem most effectively, methods and strategies for building "small but smart" mutant libraries have been developed. Herein, we compared two different strategies regarding the application of triple-code saturation mutagenesis (TCSM) at multiresidue sites of the Thermoanaerobacter brockii alcohol dehydrogenase by using distinct reduced amino-acid alphabets. By using the synthetically difficult-to-reduce prochiral ketone tetrahydrofuran-3-one as a substrate, highly R- and S-selective variants were obtained (92-99 % ee) with minimal screening. The origin of stereoselectivity was provided by molecular dynamics analyses, which is discussed in terms of the Bürgi-Dunitz trajectory. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Development of new solid-phase microextraction fibers by sol-gel technology for the determination of organophosphorus pesticide multiresidues in food.

    PubMed

    Yu, Jianxin; Wu, Caiying; Xing, Jun

    2004-05-21

    Allyloxy bisbenzo 16-crown-5 trimethoxysilane was first used as precursor to prepare the sol-gel-derived bisbenzo crown ether/hydroxyl-terminated silicone oil (OH-TSO) SPME coating. The coating procedure involving sol solution composition and conditioning process was presented. Compared with commercial SPME stationary phases, the new coatings showed higher extraction efficiency and therefore could provide higher sensitivity for organphosphorous pesticides (OPs). Limits of detection (LODs) were in the range of 0.003-1.0 ng/g for these OPs in food samples (honey, juice, orange and pakchoi). The optimal extraction conditions of the new coatings to OPs in these samples were investigated by adjusting extraction time, salt addition, extraction temperature, and dilution ratios of samples with distilled water by using SPME coupled with gas chromatography (GC)-flame photometric detection (FPD). The method was applied to determine the concentrations of OPs in real samples.

  17. Identification of beta-lactam antibiotics in tissue samples containing unknown microbial inhibitors.

    PubMed

    Moats, W A; Romanowski, R D; Medina, M B

    1998-01-01

    Antibiotic residues in animal tissues can be detected by various screening tests based on microbial inhibition. In the 7-plate assay used by the U.S. Department of Agriculture's Food Safety and Inspection Service (FSIS), penicillinase is incorporated into all but one plate to distinguish beta-lactam antibiotics from other types. However, beta-lactams such as cloxacillin and the cephalosporins are resistant to degradation by penicillinase. They may not be identified as beta-lactams by this procedure, and thus, they may be identified as unidentified microbial inhibitors (UMIs). However, these penicillinase-resistant compounds can be degraded by other beta-lactamases. The present study describes an improved screening protocol to identify beta-lactam antibiotics classified as UMIs. A multiresidue liquid chromatographic procedure based on a method for determining beta-lactams in milk was also used to identify and quantitate residues. The 2 methods were tested with 24 tissue FSIS samples classified as containing UMIs. Of these, 3 contained penicillin G, including one at a violative level, and 5 contained a metabolite of ceftiofur. The others were negative for beta-lactam antibiotics.

  18. Validation of a Multiresidue Analysis Method for 379 Pesticides in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Shin, Yongho; Lee, Jonghwa; Lee, Jiho; Lee, Junghak; Kim, Eunhye; Liu, Kwang-Hyeon; Lee, Hye Suk; Kim, Jeong-Han

    2018-04-04

    A screening method for simultaneous analysis of 379 pesticides in human serum was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Electrospray ionization with positive/negative switching mode of LC-MS/MS was adopted, and scheduled multiple reaction monitoring for each target compound was established. The limit of quantitation was 10 ng/mL for 94.5% of the total pesticides, and the correlation coefficients of calibration were ≥0.990 for 93.9% of the pesticides. For the sample preparation, scaled-down QuEChERS were used. Serum (100 μL) was extracted with acetonitrile (400 μL), partitioned with magnesium sulfate (40 mg) and sodium chloride (10 mg), and the upper layer was used for analysis without further cleanup steps. For the accuracy and precision tests, most of the pesticides showed excellent results in intra- and interday conditions. In the recovery tests at 10, 50, and 250 ng/mL, 85.8-91.8% of all target compounds satisfied the recovery range of 70-120% (relative standard deviation ≤20%).

  19. Determination of organochlorine pesticide and polychlorinated biphenyl residues in fatty fish by tandem solid-phase extraction cleanup.

    PubMed

    Schenck, F J; Calderon, L; Podhorniak, L V

    1996-01-01

    A rapid, multiresidue solid-phase extraction (SPE) technique for determination of organochlorine pesticide and polychlorinated biphenyl (PCB) residues in nonfatty fish was modified for use with fatty fish. In the modified procedures, samples are extracted with acetonitrile, and the extract is cleaned up with both C18 and Florisil SPE columns. Residues are determined by gas chromatography with electron capture detection. The original method was modified for use with fatty fish by reducing the amount of tissue extracted and by using an improved Florisil SPE cleanup. Recovery data are presented for 24 fortified organochlorine pesticide residues (0.12 ppm) and 3 fortified PCB residues (0.80 ppm) from flounder, bluefish, and shad samples, which contained 0.8, 5.4, and 22.6% fat, respectively. For the 3 types of fish, recoveries of 23 of 24 fortified organochlorine pesticide residues ranged from 55 to 129%, and recoveries of 3 fortified PCB residues ranged from 55 to 104%. There were no significant differences in recovery based on fish species and/or fat content for the majority of residues studied. This SPE method and the official AOAC method yielded comparable results for fish containing incurred organochlorine residues.

  20. High-throughput analytical techniques for multiresidue, multiclass determination of 653 pesticides and chemical pollutants in tea--Part III: Evaluation of the cleanup efficiency of an SPE cartridge newly developed for multiresidues in tea.

    PubMed

    Pang, Guo-Fang; Fan, Chun-Lin; Chang, Qiao-Ying; Li, Yan; Kang, Jian; Wang, Wen-Wen; Cao, Jing; Zhao, Yan-Bing; Li, Nan; Li, Zeng-Yin; Chen, Zong-Mao; Luo, Feng-Jian; Lou, Zheng-Yun

    2013-01-01

    A comparative study was conducted over three stages on the cleanup efficiency of SPE cartridge Cleanert TPT, newly developed for multigroups of pesticide residues in tea. In Stage I, different SPE cartridges C18, graphite carbon black (GCB), primary secondary amine (PSA), and amino (NH2) were purchased and combined into 12 different sequences. Through the comparative test on cleanup efficiency of 84 representative pesticides in tea, Envi-Carb GCB + PSA with a good cleanup effect was selected. In Stage II, GC/MS test results from the comparative study of the extraction efficiency of 201 pesticides spiked into green tea and Woolong tea with Cleanert TPT and Envi-Carb + PSA SPE showed that average recoveries fell within 70-110% and RSD <20% for 193 and 184 pesticides, respectively, for green tea, accounting for 96.0 and 91.0% of the total number, respectively. GC/MS/MS test results also found 193 and 184 pesticides, respectively, meeting the recovery and RSD conditions, accounting for 96.0 and 91.5%, respectively, of the total number. For Woolong tea samples, GC/MS results showed that with Cleanert TPT and Envi-Carb + PSA SPE for cleanup, there were 192 and 177 pesticides, respectively, meeting the conditions, accounting for 95.5 and 88.1% of the total number, respectively. GC/MS/MS results demonstrated that there were 195 and 184 pesticides, respectively, meeting the conditions, accounting for 97.0 and 91.5% of the total number, respectively. It was seen that Cleanert TPT was superior to Envi-Carb + PSA in cleanup efficiency, whether for green or Woolong tea samples, or GC/MS or GC/MS/MS determination. In Stage III, 61104 results of the average content value of pesticides and RSD (two teas xtwo Youden pair concentrations x two kinds of SPE cartridges x two instruments x 19 tests x 201 pesticides) were derived from the 19 times stability tests over 3 months by paralleling three samples every 5 days via two instruments with two kinds of SPE cartridges for cleanup, respectively, against Youden Pair samples of the 201 incurred pesticides from green and Woolong teas. The statistical analysis found that detected values from the target pesticides of the incurred Youden pair samples showed no marked differences with cleanup by either Cleanert TPT or Envi-Carb + PSA, whether for green or Woolong tea, or G/IMS or G/IM/IMS. The test results using the two aforementioned kinds of SPE cleanup for above 93% pesticides had a tolerance less than 15%, which testifies that both cartridge cleanups met the requirement for pesticide residue analysis.

  1. Sensitive multiresidue method by HS-SPME/GC-MS for 10 volatile organic compounds in urine matrix: a new tool for biomonitoring studies on children.

    PubMed

    Antonucci, Arianna; Vitali, Matteo; Avino, Pasquale; Manigrasso, Maurizio; Protano, Carmela

    2016-08-01

    A HS-SPME method coupled with GC-MS analysis has been developed for simultaneously measuring the concentration of 10 volatile organic compounds (VOCs) (benzene, toluene, ethylbenzene, o-, m-, and p-xylene, methyl tert-butyl ether, ethyl tert-butyl ether, 2-methyl-2-butyl methyl ether, and diisopropyl ether) in urine matrix as a biomonitoring tool for populations at low levels of exposure to such VOCs. These compounds, potentially toxic for human health, are common contaminants of both outdoor and indoor air, as they are released by autovehicular traffic; some of them are also present in environmental tobacco smoke (ETS). Thus, the exposure to these pollutants cannot be neglected and should be assessed. The low limits of detection and quantification (LODs and LOQs <6.5 and 7.5 ng L(-1), respectively) and the high reproducibility (CVs <4 %) make the developed method suited for biomonitoring populations exposed at low levels such as children. Further, the method is cost-effective and low in time-consumption; therefore, it is useful for investigating large populations. It has been applied to children exposed to traffic pollution and/or ETS; the relevant results are reported, and the relevant implications are discussed.

  2. Simultaneous analysis of pesticides from different chemical classes by using a derivatisation step and gas chromatography-mass spectrometry.

    PubMed

    Raeppel, Caroline; Nief, Marie; Fabritius, Marie; Racault, Lucie; Appenzeller, Brice M; Millet, Maurice

    2011-11-04

    This work presents a new method to analyse simultaneously by GC-MS 31 pesticides from different chemical classes (2,4 D, 2,4 MCPA, alphacypermethrin, bifenthrin, bromoxynil, buprofezin, carbaryl, carbofuran, clopyralid, cyprodinil, deltamethrin dicamba, dichlobenil, dichlorprop, diflufenican, diuron, fenoxaprop, flazasulfuron, fluroxypyr, ioxynil, isoxaben, mecoprop-P, myclobutanil, oryzalin, oxadiazon, picloram, tau-fluvalinate tebuconazole, triclopyr, trifluralin and trinexapac-p-ethyl). This GC-MS method will be applied to the analysis of passive samplers (Tenax(®) tubes and SPME fiber) used for the evaluation of the indoor and outdoor atmospheric contamination by non-agricultural pesticides. The method involves a derivatisation step for thermo-labile or polar pesticides. Different agents were tested and MtBSTFA (N-(t-butyldimethylsilyl)-N-methyltrifluoroacetamide), a sylilation agent producing very specific fragments [M-57], was retained. However, diuron could not be derivatised and the isocyanate product was used for identification and quantification. Pesticides which did not need a derivatisation step were not affected by the presence of the derivatisation agent and they could easily be analysed in mixture with derivatised pesticides. The method can be coupled to a thermal-desorption unit or to SPME extraction for a multiresidue analysis of various pesticides in atmospheric samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Combination of solid-phase extraction with dispersive liquid-liquid microextraction followed by GC-MS for determination of pesticide residues from water, milk, honey and fruit juice.

    PubMed

    Shamsipur, Mojtaba; Yazdanfar, Najmeh; Ghambarian, Mahnaz

    2016-08-01

    In this work, an effective preconcentration method for the extraction and determination of traces of multi-residue pesticides was developed using solid-phase extraction (SPE) coupled with dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry (GC-MS). Variables affecting the performance of both extraction steps such as type and volume of elution and extraction solvents, breakthrough volume, salt addition, extraction time were thoroughly investigated. The proposed method resulted in good linearities (R(2)>0.9915) over the ranges of 1-10,000ngkg(-1), limits of detection (LODs) in the range of 0.5-1.0ngkg(-1) at S/N=3, and precision of RSD% of ⩽11.8. Under optimal conditions, the preconcentration factors were obtained in the range of 2362-10,593 for 100mL sample solutions. Comparison of the proposed method with other ones demonstrated that SPE-DLLME method provides higher extraction efficiency and larger preconcentration factor for determination of pesticides residues. Further, it is simple, inexpensive, highly sensitive, and can be successfully applied to separation, preconcentration and determination of the pesticides (and other noxious materials) in different real food samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Multi-residue analysis of pharmaceuticals in aqueous environmental samples by online solid-phase extraction-ultra-high-performance liquid chromatography-tandem mass spectrometry: optimisation and matrix effects reduction by quick, easy, cheap, effective, rugged and safe extraction.

    PubMed

    Bourdat-Deschamps, Marjolaine; Leang, Sokha; Bernet, Nathalie; Daudin, Jean-Jacques; Nélieu, Sylvie

    2014-07-04

    The aim of this study was to develop and optimise an analytical method for the quantification of a bactericide and 13 pharmaceutical products, including 8 antibiotics (fluoroquinolones, tetracyclines, sulfonamides, macrolide), in various aqueous environmental samples: soil water and aqueous fractions of pig slurry, digested pig slurry and sewage sludge. The analysis was performed by online solid-phase extraction coupled to ultra-high performance liquid chromatography with tandem mass spectrometry (online SPE-UHPLC-MS-MS). The main challenge was to minimize the matrix effects observed in mass spectrometry, mostly due to ion suppression. They depended on the dissolved organic carbon (DOC) content and its origin, and ranged between -22% and +20% and between -38% and -93% of the signal obtained without matrix, in soil water and slurry supernatant, respectively. The very variable levels of these matrix effects suggested DOC content cut-offs above which sample purification was required. These cut-offs depended on compounds, with concentrations ranging from 30 to 290mgC/L for antibiotics (except tylosine) up to 600-6400mgC/L for the most apolar compounds. A modified Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) extraction procedure was therefore optimised using an experimental design methodology, in order to purify samples with high DOC contents. Its performance led to a compromise, allowing fluoroquinolone and tetracycline analysis. The QuEChERS extraction salts consisted therefore of sodium acetate, sodium sulfate instead of magnesium sulfate, and sodium ethylenediaminetetraacetate (EDTA) as a ligand of divalent cations. The modified QuEChERS procedure employed for the extraction of pharmaceuticals in slurry and digested slurry liquid phases reduced the matrix effects for almost all the compounds, with extraction recoveries generally above 75%. The performance characteristics of the method were evaluated in terms of linearity, intra-day and inter-day precision, accuracy and limits of quantification, which reached concentration ranges of 5-270ng/L in soil water and sludge supernatant, and 31-2400ng/L in slurry and digested slurry supernatants, depending on the compounds. The new method was then successfully applied for the determination of the target compounds in environmental samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Repercussion of the phytosanitary treatments on various models of foliage management in a Cabernet Sauvignon Vineyard (I note).

    PubMed

    Spera, G; Moretti, S; Casadei, G

    2004-01-01

    This study is the first communication about the repercussion of several phytosanitary treatments in three different training systems, differently managed in foilage, in relation to the usual phytopatologies: botrytis, acid rot, grape mildew and oldium. Particular attention to residuals of the products supplied on the foilage and present in ground and wine is paid. The considered foilage management systems are among those more spread and effective ones for a good quality wine production for Cabernet Sauvignon variety (clone R5). 11. Cordon Spur of Conegliano (C.S.C); 12. Simple Free Espalier Curtain (S.C.S.L); 13. Lyra (Lyra). The phytosanitary interventions for the foilage management systems have been compared between the company's ordinary plan and one with various and numerous active principles. The CG-ECD with Multiresidual analysis has determined the active principles residuals in the ground and in the wines. The characteristics of the wines have been determined by physical- chemical analysis; their organoleptic quality has been valued by panels of producers, oenologists, consumers and restaurant staff. The results point out a difference among the trials for the different presence of residuals. The foilage management justifies the diversity of the analytical composition of the wines. There is a substantial uniformity of judgements for the organoleptic quality. In conclusion, in this prove the judgement on the economic quality highlights the uselessness of the use of more incisive and radical active principles.

  6. Effect of food processing on degradation of hexachlorocyclohexane and its isomers in milk.

    PubMed

    Singh, Sujatha; Nelapati, Krishnaiah

    2017-03-01

    To study the effect of different food processing techniques on the degradation of organochlorine compounds (α, β, ɣ and δ hexachlorocyclohexane isomers (HCH)) residues in both natural and fortified samples of milk. Raw milk samples are collected from the local areas of Hyderabad, India. Naturally and fortified milk samples (HCH) were subjected to various food processing techniques, pasteurization (63ºC for ½ h), sterilization (121ºC for 15 min) and boiling for 5 min and analyzed by gas chromatography with electron capture detector using quick, easy, cheap, effective, rugged and safe method for multiresidue analysis of pesticides in milk with slight modification. The final mean residual concentration of pesticide in milk after heat processing and percentage of degradation were calculated with respective treatments. Heat treatments are highly effective on reduction of mean residual concentration of HCH in milk. In which Sterilization and boiling proved to be more effective in degradation of HCH isomers.

  7. The current role of high-resolution mass spectrometry in food analysis.

    PubMed

    Kaufmann, Anton

    2012-05-01

    High-resolution mass spectrometry (HRMS), which is used for residue analysis in food, has gained wider acceptance in the last few years. This development is due to the availability of more rugged, sensitive, and selective instrumentation. The benefits provided by HRMS over classical unit-mass-resolution tandem mass spectrometry are considerable. These benefits include the collection of full-scan spectra, which provides greater insight into the composition of a sample. Consequently, the analyst has the freedom to measure compounds without previous compound-specific tuning, the possibility of retrospective data analysis, and the capability of performing structural elucidations of unknown or suspected compounds. HRMS strongly competes with classical tandem mass spectrometry in the field of quantitative multiresidue methods (e.g., pesticides and veterinary drugs). It is one of the most promising tools when moving towards nontargeted approaches. Certain hardware and software issues still have to be addressed by the instrument manufacturers for it to dislodge tandem mass spectrometry from its position as the standard trace analysis tool.

  8. Evaluation of gas chromatography-tandem quadrupole mass spectrometry for the determination of organochlorine pesticides in fats and oils.

    PubMed

    Patel, Katan; Fussell, Richard J; Hetmanski, Mike; Goodall, David M; Keely, Brendan J

    2005-03-18

    A gas chromatography-tandem quadrupole mass spectrometry multi-residue method for the analysis of 19 organochlorine pesticides in fats and oils has been developed. Gel permeation chromatography was employed to remove lipid material prior to GC-MS/MS analysis. Average recoveries of the pesticides spiked at 10 and 50 microg kg(-1) into fish oil, pork fat, olive oil and hydrogenated vegetable oil were typically in the range 70-110% with relative standard deviations generally less than 10%. Calculated limits of detection are between 0.1 and 2.0 microg kg(-1) and results obtained for the analysis of proficiency test materials are in good agreement with assigned values. The higher selectivity of the GC-MS/MS compared to electron capture detection and GC-MS in selective ion monitoring mode allowed unambiguous identification and confirmation of all the target pesticides at low microg kg(-1) levels in fats and oils in a single analysis.

  9. Effects of pan cooking on micropollutants in meat.

    PubMed

    Planche, Christelle; Ratel, Jérémy; Blinet, Patrick; Mercier, Frédéric; Angénieux, Magaly; Chafey, Claude; Zinck, Julie; Marchond, Nathalie; Chevolleau, Sylvie; Marchand, Philippe; Dervilly-Pinel, Gaud; Guérin, Thierry; Debrauwer, Laurent; Engel, Erwan

    2017-10-01

    This work presents the effects of pan cooking on PCBs, PCDD/Fs, pesticides and trace elements in meat from a risk assessment perspective. Three different realistic cooking intensities were studied. A GC×GC-TOF/MS method was set up for the multiresidue analysis of 189 PCBs, 17 PCDD/Fs and 16 pesticides whereas Cd, As, Pb and Hg were assayed by ICP-MS. In terms of quantity, average PCB losses after cooking were 18±5% for rare, 30±3% for medium, and 48±2% for well-done meat. In contrast, average PCDD/F losses were not significant. For pesticides, no loss occurred for aldrin, lindane, DDE or DDD, whereas losses exceeding 80% were found for dieldrin, sulfotep or phorate. Losses close to the margin of error were observed for trace elements. These results are discussed in light of the physicochemical properties of the micropollutants as well as of water and fat losses into cooking juice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Importance of optimizing chromatographic conditions and mass spectrometric parameters for supercritical fluid chromatography/mass spectrometry.

    PubMed

    Fujito, Yuka; Hayakawa, Yoshihiro; Izumi, Yoshihiro; Bamba, Takeshi

    2017-07-28

    Supercritical fluid chromatography/mass spectrometry (SFC/MS) has great potential in high-throughput and the simultaneous analysis of a wide variety of compounds, and it has been widely used in recent years. The use of MS for detection provides the advantages of high sensitivity and high selectivity. However, the sensitivity of MS detection depends on the chromatographic conditions and MS parameters. Thus, optimization of MS parameters corresponding to the SFC condition is mandatory for maximizing performance when connecting SFC to MS. The aim of this study was to reveal a way to decide the optimum composition of the mobile phase and the flow rate of the make-up solvent for MS detection in a wide range of compounds. Additionally, we also showed the basic concept for determination of the optimum values of the MS parameters focusing on the MS detection sensitivity in SFC/MS analysis. To verify the versatility of these findings, a total of 441 pesticides with a wide polarity range (logP ow from -4.21 to 7.70) and pKa (acidic, neutral and basic). In this study, a new SFC-MS interface was used, which can transfer the entire volume of eluate into the MS by directly coupling the SFC with the MS. This enabled us to compare the sensitivity or optimum MS parameters for MS detection between LC/MS and SFC/MS for the same sample volume introduced into the MS. As a result, it was found that the optimum values of some MS parameters were completely different from those of LC/MS, and that SFC/MS-specific optimization of the analytical conditions is required. Lastly, we evaluated the sensitivity of SFC/MS using fully optimized analytical conditions. As a result, we confirmed that SFC/MS showed much higher sensitivity than LC/MS when the analytical conditions were fully optimized for SFC/MS; and the high sensitivity also increase the number of the compounds that can be detected with good repeatability in real sample analysis. This result indicates that SFC/MS has potential for practical use in the multiresidue analysis of a wide range of compounds that requires high sensitivity. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Development of high-throughput multi-residue method for non-steroidal anti-inflammatory drugs monitoring in swine muscle by LC-MS/MS.

    PubMed

    Castilhos, Tamara S; Barreto, Fabiano; Meneghini, Leonardo; Bergold, Ana Maria

    2016-07-01

    A reliable and simple method for the detection and quantification of residues of 14 non-steroidal anti-inflammatory drugs and a metamizole metabolite in swine muscle was developed using liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS). The samples were extracted with acetonitrile (ACN) in solid-liquid extraction followed by a low-temperature partitioning (LLE-LTP) process at -20 ± 2°C. After evaporation to dryness, the residue was reconstituted with hexane and a mixture of water:acetonitrile (1:1). LC separation was achieved on a reversed-phase (RP18) column with gradient elution using water (phase A) and ACN (phase B) both containing 1 mmol l(-)(1) ammonium acetate (NH4COO) with 0.025% acetic acid. Analysis was carried out on a triple-quadrupole tandem mass spectrometer (LC-MS/MS) in multiple reaction monitoring mode using an electrospray interface in negative and positive mode in a single run. Method validation was performed according to the criteria of Commission Decision No. 2002/657/EC. The matrix effect and linearity were evaluated. Decision limit (CCα), detection capability (CCβ), accuracy and repeatability of the method are also reported. The proposed method proved to be simple, easy and adequate for high-throughput analysis and was applied to routine analysis by the Brazilian Ministry of Agriculture, Livestock and Food Supply.

  12. [Multi-residue method for screening of pesticides in crops by liquid chromatography with tandem mass spectrometry].

    PubMed

    Tanizawa, Haruna; Shima, Mikie; Ikehara, Chieko; Kobata, Masakazu; Sato, Motoaki

    2005-10-01

    A simple and rapid method was developed for the screening of 82 pesticides/metabolites in a wide variety of crops, using solid-phase extraction and liquid chromatography with tandem mass spectrometry (LC/MS/MS). After extraction with methanol, the filtered extracts were made up to 100 mL and a 2 mL aliquot was subjected to solid-phase extraction. Co-extractives were removed with a C18 mini-column, while pesticides were retained on 3 kinds of mini-columns (HLB, SAX, activated carbon), and then eluted with acetonitrile. Analysis was performed by LC/MS/MS, and MS acquisition parameters were established in positive and negative ESI modes. The utility of the method was demonstrated by the analysis of 6 crops (carrot, cabbage, onion, spinach, lemon, brown rice) and one mixed vegetable juice. Of 82 compounds tested, 75 in carrot and 62 in lemon were obtained with recoveries ranging from 70-120%. For all samples tested, 75 compounds could be obtained with recoveries of over 50%, and the detection limits of most compounds were lower than 0.01 microg/g. This method provides acceptable performance for analysis of these 75 compounds. Further, by using aliquots of the extracts with small-scale mini-columns, purified samples could be obtained. This proposed method with small matrix effects, is effective and suitable for screening of multiple residual pesticides by using LC/MS/MS.

  13. A novel optimised and validated method for analysis of multi-residues of pesticides in fruits and vegetables by microwave-assisted extraction (MAE)-dispersive solid-phase extraction (d-SPE)-retention time locked (RTL)-gas chromatography-mass spectrometry with Deconvolution reporting software (DRS).

    PubMed

    Satpathy, Gouri; Tyagi, Yogesh Kumar; Gupta, Rajinder Kumar

    2011-08-01

    A rapid, effective and ecofriendly method for sensitive screening and quantification of 72 pesticides residue in fruits and vegetables, by microwave-assisted extraction (MAE) followed by dispersive solid-phase extraction (d-SPE), retention time locked (RTL) capillary gas-chromatographic separation in trace ion mode mass spectrometric determination has been validated as per ISO/IEC: 17025:2005. Identification and reporting with total and extracted ion chromatograms were facilitated to a great extent by Deconvolution reporting software (DRS). For all compounds LOD were 0.002-0.02mg/kg and LOQ were 0.025-0.100mg/kg. Correlation coefficients of the calibration curves in the range of 0.025-0.50mg/kg were >0.993. To validate matrix effects repeatability, reproducibility, recovery and overall uncertainty were calculated for the 35 matrices at 0.025, 0.050 and 0.100mg/kg. Recovery ranged between 72% and 114% with RSD of <20% for repeatability and intermediate precision. The reproducibility of the method was evaluated by an inter laboratory participation and Z score obtained within ±2. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Multiresidue determination of fluoroquinolone, sulfonamide, trimethoprim, and chloramphenicol antibiotics in urban waters in China.

    PubMed

    Peng, Xianzhi; Tan, Jianhua; Tang, Caiming; Yu, Yiyi; Wang, Zhendi

    2008-01-01

    A feasible method has been optimized to simultaneously determine multiclass antibiotic residues, including sulfonamides, fluoroquinolones, trimethoprim, and chloramphenicol in urban riverine water and wastewater by off-line solid phase extraction and high-performance liquid chromatography coupled with a diode-array ultraviolet detector and a fluorescence detector. Internal standard and standard addition methods were used in combination to identify and quantify these antibiotics to compensate for the matrix interference. The method quantification limits (MQLs) were determined to be 0.035 to 0.100 microg/L and 0.100 to 0.300 microg/L for the riverine water and wastewater, respectively. Recoveries of the investigated antibiotics ranged from 63 to 126%. Sulfamethoxazole was the most frequently detected antibiotic residue in Guangzhou section of the Major Pearl River, South China, with a maximum level of 0.510 microg/L. Fluoroquinolone antibiotics were relatively less detected with a maximum level of 0.459 microg/L. The maximum concentration of sulfamethoxazole reached 5.597 microg/L in the raw wastewater from a large-scale sewage treatment plant in Guangzhou city. Around 30% of sulfamethoxazole might survive the primary clarification and biotreatment processes in the sewage treatment plant. None of the investigated antibiotics have been found above MQLs in the final effluent after chlorine disinfection.

  15. Multiresidue analysis of 47 pesticides in cooked wheat flour and polished rice by liquid chromatography with tandem mass spectrometry.

    PubMed

    Lee, Sung Jung; Park, Hyeong Jin; Kim, Wooseong; Jin, Jong Sung; Abd El-Aty, A M; Shim, Jae-Han; Shin, Sung Chul

    2009-04-01

    Liquid chromatography in conjunction with tandem mass spectrometry was used to directly quantify of 47 pesticide residues from cooked wheat flour and polished rice, which are the most widely consumed cereals in the Republic of Korea. The sample clean-up was carried out according to the method established by the Korea Food and Drug Administration. The mobile phase for liquid chromatography separation consisted of water and 5 mm methanolic ammonium formate. Tandem mass spectroscopy experiments were performed in electrospray ionization positive mode and the multiple reaction monitoring mode. The matrix effects estimated for the 47 pesticides had a mean value of 99% and ranged from 45 to 147%. High recoveries (70-140%) and relative standard deviations (< or = 20%) were achieved for most of the pesticides tested. The method used in this study allowed for rapid quantification and identification of low levels of pesticides in cooked wheat flour and polished rice samples. Of the screened pesticide residues, only tricyclazole and fenobucarb were found in polished rice samples. However, no samples contained residues above the MRL established by the Korea Food and Drug Administration.

  16. Spectroscopic and molecular modeling approaches to investigate the interaction of bisphenol A, bisphenol F and their diglycidyl ethers with PPARα.

    PubMed

    Zhang, Jie; Zhang, Tiehua; Guan, Tianzhu; Ruan, Ping; Ren, Dayong; Dai, Weichang; Yu, Hansong; Li, Tiezhu

    2017-08-01

    A fluorescence polarization (FP) assay for the simultaneous determination of bisphenol A (BPA), bisphenol F (BPF), bisphenol A diglycidyl ether (BADGE) and bisphenol F diglycidyl ether (BFDGE) was developed. The method was based on the competition between bisphenols (BPs) and fluorescein-labeled dexamethasone derivative (Dex-fl) for mouse peroxisome proliferator-activated receptor α ligand binding domain (mPPARα-LBD). A recombinant soluble protein derivative mPPARα-LBD* was prepared, then in vitro binding of 4 BPs to mPPARα-LBD* was investigated. Fluorescence polarization assay showed that these compounds exhibited different binding potencies with mPPARα-LBD*. Additionally, molecular dynamics simulations were performed to further understand the mechanism of BPs binding affinity for mPPARα-LBD*. Docking results elucidated that the driving forces for the binding of BPs to mPPARα-LBD* were predominantly dependent on hydrophobic and hydrogen-bonding interactions. Comparison of the calculated binding energies vs. experimental binding affinities yielded a good correlation (R 2  = 0.7258). The proposed method has potential for multi-residue detection of BPA, BPF, BADGE, and BFDGE. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Accelerated solvent extraction by using an 'in-line' clean-up approach for multiresidue analysis of pesticides in organic honey.

    PubMed

    Chiesa, Luca Maria; Labella, Giuseppe Federico; Panseri, Sara; Britti, Domenico; Galbiati, Fabrizio; Villa, Roberto; Arioli, Francesco

    2017-05-01

    The worldwide loss of honeybee colonies may be due to their exposure to several contaminants (i.e., pesticides); such contamination may also have impacts on consumers' health. Therefore, it is essential to develop quick and new methods to detect several pesticide residues in honey samples. In this study, the effectiveness of accelerated solvent extraction (ASE) was compared with QuEChERS methods for the analysis of 53 pesticides in organic honey by gas chromatography-triple quadrupole mass spectrometry. Two simple and rapid ASE methods with 'in-line' clean-up were optimised and then compared with QuEChERS. Hexane-ethyl acetate (Hex:EtAc) and Florisil were chosen as extraction solvent and retainer for the first ASE method respectively; acetonitrile and a primary-secondary amine phase (ACN-PSA) were selected for the second ASE method. The methods were validated according to the European Union SANTE/11945/2015 guidelines. The validation parameters showed that QuEChERS and ASE with PSA as retainer had better repeatability than ASE with Hex:EtAc and Florisil. In particular, QuEChERS and ASE (ACN-PSA) showed good recovery, according to the SANTE criteria, for the majority of investigated pesticides. Conversely, when ASE with Hex:EtAc and Florisil was used as the retainer, several compounds showed recoveries lower than the acceptable value of 70%. The ASE in-line method was finally applied to evaluate pesticide concentration in organic honey samples.

  18. Contaminants of emerging concern in surface waters in Barbados, West Indies.

    PubMed

    Edwards, Quincy A; Kulikov, Sergei M; Garner-O'Neale, Leah D; Metcalfe, Chris D; Sultana, Tamanna

    2017-11-14

    Contaminants of emerging concern (CECs), including pharmaceuticals, artificial sweeteners, steroid hormones, and current-use pesticides have been detected in surface waters around the world, but to date, there have been no reports in the peer-reviewed literature on the levels of these classes of contaminants in freshwater resources in the Caribbean region. In the present study, multi-residue solid phase extraction (SPE) and liquid chromatography with tandem mass spectroscopy (LC-MS/MS) were used to analyze grab samples of surface waters collected from five different watersheds in Barbados, West Indies. The artificial sweeteners (AS), acesulfame, cyclamate, saccharin, and sucralose were widely detected in the watersheds, indicating contamination from domestic wastewater, and the concentrations of these chemical tracers in water were correlated with the concentrations of the non-prescription pharmaceutical, ibuprofen (R 2 values of 0.4-0.6). Surprisingly, the concentrations of another chemical tracer of domestic wastewater, caffeine were not correlated with ibuprofen or AS concentrations. Several other prescription pharmaceuticals and the steroid hormones, estrone and androstenedione, were detected in selected watersheds at low ng/L concentrations. The fungicide, chlorothalonil was widely detected in surface waters at low (< 10 ng/L) concentrations, but the levels of this pesticide were not correlated with the concentrations of the other target analytes, indicating that the source of this pesticide is not domestic wastewater. An informal survey of disposal practices for out of date or unused drugs by pharmacies in Barbados indicated that disposal into trash destined for the landfill and flushing down the sink might be significant sources of contamination of water resources by pharmaceuticals.

  19. Multiresidue screening of milk withheld for sale at dairy farms in central New York State.

    PubMed

    Pereira, R V; Siler, J D; Bicalho, R C; Warnick, L D

    2014-03-01

    Many of the drugs commonly used in lactating dairy cows result in residues in the milk, prohibiting its sale for human consumption. Milk withheld for sale because of drug treatment or from cows with high somatic cell counts is commonly called "waste milk." One-third of dairy farms in the United States use waste milk to feed preweaned dairy calves. Limited information is currently available on the effect of this practice on the selection and dissemination of antibiotic-resistant bacteria. Pooled waste milk samples were collected from 34 dairy farms in central New York State with the objective of detecting the presence and quantity of drug residues in these samples. Samples were collected and refrigerated using ice packs and then stored at 4°C upon arrival at the Cornell laboratory (Ithaca, NY). Screening for β-lactam, tetracycline, and sulfonamide residues in the milk was performed using commercial enzyme-linked receptor-binding assay (SNAP) tests (Idexx Laboratories Inc., Westbrook, ME). Samples with a positive SNAP test were selected for screening using a multiresidue liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. The SNAP tests revealed that 75, 14.3, and 7.1% of waste milk samples (n=34) contained β-lactam, tetracycline, and sulfamethazine residues, respectively. Of the samples sent for LC-MS/MS (n=28), half had detectable quantities of drug residues. The most prevalent drugs detected by LC-MS/MS were ceftiofur (39.2%; mean ± SE concentration=0.151 ± 0.042 μg/mL), penicillin G (14.2%; mean ± SE concentration=0.008 ± 0.001 µg/mL), and ampicillin (7.1%; mean ± SE concentration=0.472 ± 0.43 µg/mL). In addition, one sample had detectable concentrations of oxytetracycline and one sample had detectable concentrations of sulfadimethoxine. These results provide insight on drug residues present in waste milk from select farm in upstate New York, and additionally indicate the need for additional studies targeting on-farm treatments that could degrade drug residues present in waste milk and reduce the potential effects on the biosphere from the disposal and use of waste milk as a feed source. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  20. A green chemometrics-assisted fluorimetric detection method for the direct and simultaneous determination of six polycyclic aromatic hydrocarbons in oil-field wastewaters

    NASA Astrophysics Data System (ADS)

    Gu, Hui-Wen; Zhang, Shan-Hui; Wu, Bai-Chun; Chen, Wu; Wang, Jing-Bo; Liu, Yang

    2018-07-01

    Oil-field wastewaters contain high level of polycyclic aromatic hydrocarbons (PAHs), which have to be analyzed to assess the environmental effects before discharge. In this work, a green fluorimetric detection method that combines excitation-emission matrix (EEM) fluorescence with parallel factor analysis (PARAFAC) algorithm was firstly developed to achieve the direct and simultaneous determination of six U.S. EPA PAHs in two different kinds of complex oil-field wastewaters. Due to the distinctive "second-order advantage", neither time-consuming sample pretreatments nor toxic organic reagents were involved in the determination. By using the environment-friendly "mathematical separation" of PARAFAC, satisfactory quantitative results and reasonable spectral profiles for six PAHs were successfully extracted from the total EEM signals of oil-field wastewaters without need of chromatographic separation. The limits of detection of six PAHs were in the range of 0.09-0.72 ng mL-1, and the average spiked recoveries were between (89.4 ± 4.8)% and (109.1 ± 5.8)%, with average relative predictive errors <2.93%. In order to further confirm the accuracy of the proposed method, the same batch oil-field wastewater samples were analyzed by the recognized GC-MS method. t-test demonstrated that no significant differences exist between the quantitative results of the two methods. Given the advantages of green, fast, low-cost and high-sensitivity, the proposed method is expected to be broadened as an appealing alternative method for multi-residue analysis of overlapped PAHs in complex wastewater samples.

  1. Analysis of illicit dietary supplements sold in the Italian market: identification of a sildenafil thioderivative as adulterant using UPLC-TOF/MS and GC/MS.

    PubMed

    Damiano, Fabio; Silva, Claudia; Gregori, Adolfo; Vacondio, Federica; Mor, Marco; Menozzi, Mattia; Di Giorgio, Domenico

    2014-05-01

    Identification of pharmaceutical active ingredients sildenafil and tadalafil and the characterization of a dimethylated thio-derivative of sildenafil, called thioaildenafil or thiodimethylsildenafil, in illicit dietary supplements were described. A multi-residual ultra-performance liquid chromatography-time of flight mass spectrometry (UPLC-TOF/MS) method was developed to screen for the presence of the phosphodiesterase-5 (PDE-5) inhibitors sildenafil, tadalafil, and vardenafil and their analogues thioaildenafil and thiohomosildenafil in powders and pharmaceutical dosage forms. The study was developed in connection with an operation supervised by the Italian Medicines Agency (A.I.F.A.), aimed to monitor dietary supplements in the Italian market. In two of the eleven specimens under investigation, high-resolution mass spectrometry (HR-MS) allowed the identification of the PDE-5 inhibitors sildenafil and tadalafil, while another specimen proved to contain a unapproved dimethylated thioderivative of sildenafil, thioaildenafil or thiodimethylsildenafil, identified for the first time in Italy as adulterant in food supplements. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  2. Development, validation and application of a SDME/GC-FID methodology for the multiresidue determination of organophosphate and pyrethroid pesticides in water.

    PubMed

    Pinheiro, Anselmo de Souza; de Andrade, Jailson B

    2009-10-15

    A single-drop microextraction (SDME) procedure was developed for the analysis of organophosphorus and pyrethroid pesticides in water by gas chromatography (GC) with flame ionization detection (GC-FID). The significant parameters that affect SDME performance, such as the selection of microextraction solvent, solvent volume, extraction time, and stirring rate, were studied and optimized using a tool screening factorial design. The limits of detection (LODs) in water for the four investigated compounds were between 0.3 and 3.0 microgL(-1), with relative standard deviations ranging from 7.7 to 18.8%. Linear response data were obtained in the concentration range of 0.9-6.0 microg L(-1) (lambda-cyhalothrin), 3.0-60.0 microg L(-1) (methyl parathion), 9.0-60.0 microg L(-1) (ethion), and 9.0-30.0 microg L(-1) (permethrin), with correlation coefficients ranging from 0.9337 to 0.9977. The relative recoveries for the spiked water ranged from 73.0 to 104%. Environmental water samples (n=26) were successfully analyzed using the proposed method and methyl parathion presented concentration up to 2.74 microg L(-1). The SDME method, coupled with GC-FID analysis, provided good precision, accuracy, and reproducibility over a wide linear range. Other highlights of the method include its ease of use and its requirement of only small volumes of both organic solvent and sample.

  3. Fast Gas Chromatography with Tandem Mass Spectrometry Analysis of Selected Persistent Organic Pollutants and Organophosphorus and Synthetic Pyrethroid Pesticides in Indian Prawn (Fenneropenaeus indicus) in Compliance with the EU-MRLs.

    PubMed

    Sawant, Durvesh; Kelkar, Jitendra; Rasam, Pratap; Datar, Ajit; Hase, Prashant; Handique, Dheeraj; Bhone, Ankush; Chiplunkar, Sanket; Hate, Manish

    2017-05-01

    A fast GC with tandem MS method was developed and validated for multiresidue determination of 95 chemical contaminants (24 synthetic pyrethroids, 17 organochlorines, 17 organophosphorus compounds, 18 polycyclic aromatic hydrocarbons, and 19 polychlorinated biphenyls) in Indian prawns (Fenneropenaeus indicus) as per the European Union maximum residual limit requirements. Chromatographic separation and MS determination were achieved within a short run time of 18 min, without compromising sensitivity and specificity. Our findings revealed a 2.5× reduction in the run time compared with conventional GC methods. Sample preparation involved a QuEChERS-based extraction of 10 g sample with 10 mL acidified acetonitrile (1% acetic acid) and phase separation with 6 g anhydrous magnesium sulfate and 1.5 g sodium acetate. The extract was cleaned in two steps, first by dispersive cleanup with primary secondary amine and then by C18 SPE cartridge. The regression coefficients of linearity (r2) for the concentration range of 5-50 ng/mL were >0.99 for all the compounds. Recoveries at 5 and 10 ng/g levels were within the acceptable range of 70-120%. The repeatability (RSDr) and within-laboratory reproducibility (RSDwR) precisions were ≤20%. The method was successfully applied for analysis of the real world samples for incurred residues.

  4. Multiclass method for the quantification of 92 veterinary antimicrobial drugs in livestock excreta, wastewater, and surface water by liquid chromatography with tandem mass spectrometry.

    PubMed

    Gao, Jinfang; Cui, Yonghui; Tao, Yanfei; Huang, Lingli; Peng, Dapeng; Xie, Shuyu; Wang, Xu; Liu, Zhenli; Chen, Dongmei; Yuan, Zonghui

    2016-11-01

    A simple multiresidue method was developed for detecting and quantifying 92 veterinary antimicrobial drugs from eight classes (β-lactams, quinolones, sulfonamides, tetracyclines, lincomycins, macrolides, chloramphenicols, and pleuromutilin) in livestock excreta and water by liquid chromatography with tandem mass spectrometry. The feces samples were extracted by ultrasound-assisted extraction with a mixture of acetonitrile/water (80:20, v/v) and edetate disodium, followed by a cleanup using solid-phase extraction with an amino cartridge. Water samples were purified with hydrophilic-lipophilic balance solid-phase extraction column. Urine samples were extracted with acetonitrile and edetate disodium. Detection of veterinary antimicrobial drugs was achieved by liquid chromatography with tandem mass spectrometry using both positive and negative electrospray ionization mode. The recovery values of veterinary antimicrobial drugs in feces, urine, and water samples were 75-99, 85-110, and 85-101% and associated relative standard deviations were less than 15, 10, and 8%, respectively. The limits of quantification in feces, urine, and water samples were 0.5-1, 0.5-1, and 0.01-0.05 μg/L, respectively. This method was applied to determine real samples obtained from local farms and provides reliable quantification and identification results of 92 veterinary antimicrobial drugs in livestock excreta and water. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Identification of significant transport processes for organic micropollutant classes during soil aquifer treatment (SAT) - a controlled field experiment

    NASA Astrophysics Data System (ADS)

    Nödler, Karsten; Licha, Tobias; Sauter, Martin

    2010-05-01

    Supplementing existing water resources with alternative sources of water is a challenge in semi-arid areas, as deterioration of water quality must be avoided. Soil aquifer treatment (SAT) can greatly improve the quality of the injected water by attenuation of organic pollutants via sorption and degradation processes. However, only little is known about the specific transport processes of organic micropollutants under artificial recharge conditions. Organic micropollutants such as pharmaceuticals and their metabolites exhibit a wide range of chemical properties and may undergo very different environmental processes resulting in specific reactions within specified environments. In the presented study fate and transport processes of 25 organic micropollutants (iodinated contrast media, antihypertensive agents, antibiotics, anticonvulsants, lipid regulators, anti-inflammatories, antihistamines and analgesics) were investigated under SAT conditions in a controlled field experiment. Secondary treated effluent (STE) containing the compounds of interest was introduced into the aquifer by an infiltration pond and shallow wells in the vicinity were used for water quality monitoring. By means of strategic sampling procedure and a specialized multi-residue analytical method based on high-performance liquid chromatography / tandem mass spectrometry (LC/MS-MS) 3 main transport processes were identified: 1. Transport of non-polar compounds according to their respective octanol-water distribution coefficient (Kow) 2. Cation exchange 3. Colloidal transport Identification of transport processes 2 & 3 was not expected to act as a transport controlling process. Results of the positively charged beta-blockers sotalol, atenolol and metoprolol gave clear evidence for cation exchange processes of the compounds with the aquifer material. Correlation of turbidity and concentrations of macrolide antibiotics (clarithromycin, erythromycin and roxithromycin) demonstrated the colloidal transport of the respective compounds. Concentrations of almost all micropollutants decreased with increasing soil passage. However, since compounds transported by processes 2 & 3 can be re-mobilized by changing water chemistry, the importance of a diligent characterisation of aquifer material and raw water is apparent for risk assessment. The experiments were conducted within the context of the project GABARDINE, funded by the European Commission.

  6. Gas chromatography/mass spectrometry comprehensive analysis of organophosphorus, brominated flame retardants, by-products and formulation intermediates in water.

    PubMed

    Cristale, Joyce; Quintana, Jordi; Chaler, Roser; Ventura, Francesc; Lacorte, Silvia

    2012-06-08

    A multiresidue method based on gas chromatography coupled to quadrupole mass spectrometry was developed to determine organophosphorus flame retardants, polybromodiphenyl ethers (BDEs 28, 47, 99, 100, 153, 154, 183 and 209), new brominated flame retardants, bromophenols, bromoanilines, bromotoluenes and bromoanisoles in water. Two ionization techniques (electron ionization--EI, and electron capture negative ionization--ECNI) and two acquisition modes (selected ion monitoring--SIM, and selected reaction monitoring--SRM) were compared as regards to mass spectral characterization, sensitivity and quantification capabilities. The highest sensitivity, at expenses of identification capacity, was obtained by GC-ECNI-MS/SIM for most of the compounds analyzed, mainly for PBDEs and decabromodiphenyl ethane while GC-EI-MS/MS in SRM was the most selective technique and permitted the identification of target compounds at the pg level, and identification capabilities increased when real samples were analyzed. This method was further used to evaluate the presence and behavior of flame retardants within a drinking water treatment facility. Organophosphorus flame retardants were the only compounds detected in influent waters at levels of 0.32-0.03 μg L⁻¹, and their elimination throughout the different treatment stages was evaluated. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Validation of a QuEChERS-based gas chromatographic method for analysis of pesticide residues in Cassia angustifolia (senna).

    PubMed

    Tripathy, Vandana; Saha, Ajoy; Patel, Dilipkumar J; Basak, B B; Shah, Paresh G; Kumar, Jitendra

    2016-08-02

    A simple multi-residue method based on modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) approach was established for the determination of 17 organochlorine (OC), 15 organophosphorous (OP) and 7 synthetic pyrethroid (SP) pesticides in an economically important medicinal plant of India, Senna (Cassia angustifolia), by gas chromatography coupled to electron capture and flame thermionic detectors (GC/ECD/FTD) and confirmation of residues was done on gas chromatograph coupled with mass spectrometry (GC-MS). The developed method was validated by testing the following parameters: linearity, limit of detection (LOD), limit of quantification (LOQ), matrix effect, accuracy-precision and measurement uncertainty; the validation study clearly demonstrated the suitability of the method for its intended application. All pesticides showed good linearity in the range 0.01-1.0 μg mL(-1) for OCs and OPs and 0.05-2.5 μg mL(-1) for SPs with correlation coefficients higher than 0.98. The method gave good recoveries for most of the pesticides (70-120%) with intra-day and inter-day precision < 20% in most of the cases. The limits of detection varied from 0.003 to 0.03 mg kg(-1), and the LOQs were determined as 0.01-0.049 mg kg(-1). The expanded uncertainties were <30%, which was distinctively less than a maximum default value of ±50%. The proposed method was successfully applied to determine pesticide residues in 12 commercial market samples obtained from different locations in India.

  8. Development of an online SPE-UHPLC-MS/MS method for the multiresidue analysis of the 17 compounds from the EU "Watch list".

    PubMed

    Gusmaroli, Lucia; Insa, Sara; Petrovic, Mira

    2018-04-24

    During the last decades, the quality of aquatic ecosystems has been threatened by increasing levels of pollutions, caused by the discharge of man-made chemicals, both via accidental release of pollutants as well as a consequence of the constant outflow of inadequately treated wastewater effluents. For this reason, the European Union is updating its legislations with the aim of limiting the release of emerging contaminants. The Commission Implementing Decision (EU) 2015/495 published in March 2015 drafts a "Watch list" of compounds to be monitored Europe-wide. In this study, a methodology based on online solid-phase extraction (SPE) ultra-high-performance liquid chromatography coupled to a triple-quadrupole mass spectrometer (UHPLC-MS/MS) was developed for the simultaneous determination of the 17 compounds listed therein. The proposed method offers advantages over already available methods, such as versatility (all 17 compounds can be analyzed simultaneously), shorter time required for analysis, robustness, and sensitivity. The employment of online sample preparation minimized sample manipulation and reduced dramatically the sample volume needed and time required, dramatically the sample volume needed and time required, thus making the analysis fast and reliable. The method was successfully validated in surface water and influent and effluent wastewater. Limits of detection ranged from sub- to low-nanogram per liter levels, in compliance with the EU limits, with the only exception of EE2. Graphical abstract Schematic of the workflow for the analysis of the Watch list compounds.

  9. Determination of neonicotinoid pesticides residues in agricultural samples by solid-phase extraction combined with liquid chromatography-tandem mass spectrometry.

    PubMed

    Xie, Wen; Han, Chao; Qian, Yan; Ding, Huiying; Chen, Xiaomei; Xi, Junyang

    2011-07-15

    This work reports a new sensitive multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for detection, confirmation and quantification of six neonicotinoid pesticides (dinotefuran, thiamethoxam, clothiandin, imidacloprid, acetamiprid and thiacloprid) in agricultural samples (chestnut, shallot, ginger and tea). Activated carbon and HLB solid-phase extraction cartridges were used for cleaning up the extracts. Analysis is performed by LC-MS/MS operated in the multiple reaction monitoring (MRM) mode, acquiring two specific precursor-product ion transitions per target compound. Quantification was carried by the internal standard method with D(4)-labeled imidacloprid. The method showed excellent linearity (R(2)≥0.9991) and precision (relative standard deviation, RSD≤8.6%) for all compounds. Limits of quantification (LOQs) were 0.01 mg kg(-1) for chestnut, shallot, ginger sample and 0.02 mg kg(-1) for tea sample. The average recoveries, measured at three concentrations levels (0.01 mg kg(-1), 0.02 mg kg(-1) and 0.1 mg kg(-1) for chestnut, shallot, ginger sample, 0.02 mg kg(-1), 0.04 mg kg(-1) and 0.2 mg kg(-1) for tea sample), were in the range 82.1-108.5%. The method was satisfactorily validated for the analysis of 150 agricultural samples (chestnut, shallot, ginger and tea). Imidacloprid and acetamiprid were detected at concentration levels ranging from 0.05 to 3.6 mg kg(-1). Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Multiresidue determination of chlorophenoxy acid herbicides in human urine samples by use of solid-phase extraction and capillary LC-UV detection.

    PubMed

    Rosales-Conrado, N; León-González, M E; Pérez-Arribas, L V; Polo-Díez, L M

    2008-01-01

    Chlorophenoxy acid herbicides are intensively applied to get rid of unwanted plants because of their low cost and selectivity. Due to their toxicity, which depends on their chemical form, the European Community has established legal directives to restrict their use and to control their maximum residue levels in several matrices. Determination of chlorophenoxy acids-2,4-dichlorophenoxyacetic acid (2,4-D), 4-chloro-2-methylphenoxyacetic acid (MCPA), 2-(2,4-dichlorophenoxy)propanoic acid (2,4-DP), 2-(4-chloro-2-methylphenoxy)propanoic acid (MCPP), 4-(4-chloro-2-methylphenoxy)butanoic acid (MCPB) and 2-(2,4,5-trichlorophenoxy)propanoic acid (2,4,5-TP) in spiked human urine samples has been carried out by capillary LC, after solid-phase extraction on a column packed with silica C18 restricted-access material. Chromatographic analysis was performed in gradient-elution mode at 25 degrees C, with injection of 20 microL low-organic-solvent composition herbicide solutions for focusing purposes on the head of the capillary column, and diode array detection at 232 nm. Urine samples collected during 24 h from healthy and unexposed volunteers were spiked in the concentration range 25-150 microg L(-1); recoveries obtained were between 66 and 100% (n = 6 for each spiked level) and RSDs (relative standard deviations) were between 1 and 5%. Detection limits in the urine samples from volunteers were between 3.5 and 6.0 microg L(-1). The developed methodology has allowed the clean-up and preconcentration of low volumes of untreated human urine without previous treatment, showing the effectiveness of the employed SPE sorbent for extracting the target analytes and ultimately resulting in the reduction of the sample-preparation time.

  11. Analytical quality by design: a tool for regulatory flexibility and robust analytics.

    PubMed

    Peraman, Ramalingam; Bhadraya, Kalva; Padmanabha Reddy, Yiragamreddy

    2015-01-01

    Very recently, Food and Drug Administration (FDA) has approved a few new drug applications (NDA) with regulatory flexibility for quality by design (QbD) based analytical approach. The concept of QbD applied to analytical method development is known now as AQbD (analytical quality by design). It allows the analytical method for movement within method operable design region (MODR). Unlike current methods, analytical method developed using analytical quality by design (AQbD) approach reduces the number of out-of-trend (OOT) results and out-of-specification (OOS) results due to the robustness of the method within the region. It is a current trend among pharmaceutical industry to implement analytical quality by design (AQbD) in method development process as a part of risk management, pharmaceutical development, and pharmaceutical quality system (ICH Q10). Owing to the lack explanatory reviews, this paper has been communicated to discuss different views of analytical scientists about implementation of AQbD in pharmaceutical quality system and also to correlate with product quality by design and pharmaceutical analytical technology (PAT).

  12. Analytical Quality by Design: A Tool for Regulatory Flexibility and Robust Analytics

    PubMed Central

    Bhadraya, Kalva; Padmanabha Reddy, Yiragamreddy

    2015-01-01

    Very recently, Food and Drug Administration (FDA) has approved a few new drug applications (NDA) with regulatory flexibility for quality by design (QbD) based analytical approach. The concept of QbD applied to analytical method development is known now as AQbD (analytical quality by design). It allows the analytical method for movement within method operable design region (MODR). Unlike current methods, analytical method developed using analytical quality by design (AQbD) approach reduces the number of out-of-trend (OOT) results and out-of-specification (OOS) results due to the robustness of the method within the region. It is a current trend among pharmaceutical industry to implement analytical quality by design (AQbD) in method development process as a part of risk management, pharmaceutical development, and pharmaceutical quality system (ICH Q10). Owing to the lack explanatory reviews, this paper has been communicated to discuss different views of analytical scientists about implementation of AQbD in pharmaceutical quality system and also to correlate with product quality by design and pharmaceutical analytical technology (PAT). PMID:25722723

  13. Multi-residue analysis of pesticide residues in mangoes using solid-phase microextraction coupled to liquid chromatography and UV-Vis detection.

    PubMed

    Filho, Adalberto M; dos Santos, Fábio N; Pereira, Pedro A de Paula

    2011-11-01

    A sensitive and efficient solid-phase microextraction method, based on liquid chromatography and UV-Vis detection, was developed and validated as an alternative method for sample screening prior to LC-MS analysis. It enables the simultaneous determination of ten pesticides in mango fruits. The fiber used was polydimethylsiloxane while optimum SPME conditions employed have been developed and optimized in a previous work. The desorption process was performed in static mode, using acetonitrile as a solvent. The results indicate that the DI-SPME/HPLC/UV-Vis procedure resulted in good linear range, accuracy, precision and sensibility and is adequate for analyzing pesticide residues in mango fruits. The limits of detection (0.6-3.3 μg/kg) and quantification (2.0-10.0 μg/kg) were achieved with values lower than the maximum residue levels (MRLs) established by Brazilian legislation for all pesticides in this study. The average recovery rates obtained for each pesticide ranged from 71.6 to 104.3% at three fortification levels, with the relative standard deviation ranging from 4.3 to 18.6%. The proposed method was applied for the determination of the aforementioned compounds in commercial mango samples and residues of azoxystrobin, fenthion, permethrin, abamectin and bifenthrin were detected in the mango samples, although below the MRLs established by Brazilian legislation. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Determination of household and industrial chemicals, personal care products and hormones in leafy and root vegetables by liquid chromatography-tandem mass spectrometry.

    PubMed

    Aparicio, Irene; Martín, Julia; Abril, Concepción; Santos, Juan Luis; Alonso, Esteban

    2018-01-19

    A multiresidue method has been developed for the determination of emerging pollutants in leafy and root vegetables. Selected compounds were 6 perfluoroalkyl compounds (5 perfluorocarboxylic acids and perfluorooctanesulfonic acid), 3 non-ionic surfactants (nonylphenol and nonylphenolethoxylates), 8 anionic surfactants (4 alkylsulfates and 4 linear alkylbenzene sulfonates), 4 preservatives (parabens), 2 biocides (triclosan and triclocarban), 2 plasticizers (bisphenol A and di-(2-ethylhexyl)phthalate), 6 UV-filters (benzophenones) and 4 hormones. The method is based on ultrasound-assisted extraction, clean-up by dispersive solid-phase extraction (d-SPE) and liquid chromatography-tandem mass spectrometry analysis. Due to the diversity of the physico-chemical properties of the target compounds, and to better evaluate the influence of sample treatment variables in extraction efficiencies, Box-Behnken design was applied to optimize extraction solvent volume, number of extraction cycles and d-SPE sorbent amount. Linearity (R 2 ) higher than 0.992, accuracy (expressed as relative recoveries) in the range from 81 to 126%, precision (expressed as relative standard deviation) lower than 19% and limits of detection between 0.025 and 12.5ngg -1 dry weight were achieved. The method was applied to leafy vegetables (lettuce, spinach and chard) and root vegetables (carrot, turnip and potato) from a local market. The highest concentrations corresponded to the surfactants reaching levels up to 114ngg -1 (dry weight), in one of the lettuce samples analyzed. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Development and validation of a streamlined method designed to detect residues of 62 veterinary drugs in bovine kidney using ultra-high performance liquid chromatography--tandem mass spectrometry.

    PubMed

    Lehotay, Steven J; Lightfield, Alan R; Geis-Asteggiante, Lucía; Schneider, Marilyn J; Dutko, Terry; Ng, Chilton; Bluhm, Louis; Mastovska, Katerina

    2012-08-01

    In the USA, the US Department of Agriculture's Food Safety and Inspection Service (FSIS) conducts the National Residue Program designed to monitor veterinary drug and other chemical residues in beef and other slaughtered food animals. Currently, FSIS uses a 7-plate bioassay in the laboratory to screen for antimicrobial drugs in bovine kidneys from those animals tested positive by inspectors in the slaughter establishments. The microbial inhibition bioassay has several limitations in terms of monitoring scope, sensitivity, selectivity, and analysis time. Ultra-high performance liquid chromatography - tandem mass spectrometry (UHPLC-MS/MS) has many advantages over the bioassay for this application, and this study was designed to develop, evaluate, and validate a fast UHPLC-MS/MS method for antibiotics and other high-priority veterinary drugs in bovine kidney. Five existing multi-class, multi-residue methods from the literature were tested and compared, and each performed similarly. Experiments with incurred samples demonstrated that a 5-min shake of 2 g homogenized kidney with 10 ml of 4/1 (v/v) acetonitrile/water followed by simultaneous clean-up of the initial extract with 0.5 g C18 and 10 ml hexane gave a fast, simple, and effective sample preparation method for the <10 min UHPLC-MS/MS analysis. An extensive 5-day validation process demonstrated that the final method could be used to acceptably screen for 54 of the 62 drugs tested, and 50 of those met qualitative MS identification criteria. Quantification was not needed in the application, but the method gave ≥ 70% recoveries and ≤ 25% reproducibilities for 30 of the drugs. Published 2012. This article is a U.S. Government work and is in the public domain of the USA.

  16. 7 CFR 94.303 - Analytical methods.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Analytical methods. 94.303 Section 94.303 Agriculture... POULTRY AND EGG PRODUCTS Processed Poultry Products § 94.303 Analytical methods. The analytical methods... latest edition of the Official Methods of Analysis of AOAC INTERNATIONAL, Suite 500, 481 North Frederick...

  17. 7 CFR 94.303 - Analytical methods.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Analytical methods. 94.303 Section 94.303 Agriculture... POULTRY AND EGG PRODUCTS Processed Poultry Products § 94.303 Analytical methods. The analytical methods... latest edition of the Official Methods of Analysis of AOAC INTERNATIONAL, Suite 500, 481 North Frederick...

  18. 7 CFR 94.303 - Analytical methods.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Analytical methods. 94.303 Section 94.303 Agriculture... POULTRY AND EGG PRODUCTS Processed Poultry Products § 94.303 Analytical methods. The analytical methods... latest edition of the Official Methods of Analysis of AOAC INTERNATIONAL, Suite 500, 481 North Frederick...

  19. 7 CFR 94.303 - Analytical methods.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Analytical methods. 94.303 Section 94.303 Agriculture... POULTRY AND EGG PRODUCTS Processed Poultry Products § 94.303 Analytical methods. The analytical methods... latest edition of the Official Methods of Analysis of AOAC INTERNATIONAL, Suite 500, 481 North Frederick...

  20. 7 CFR 94.303 - Analytical methods.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Analytical methods. 94.303 Section 94.303 Agriculture... POULTRY AND EGG PRODUCTS Processed Poultry Products § 94.303 Analytical methods. The analytical methods... latest edition of the Official Methods of Analysis of AOAC INTERNATIONAL, Suite 500, 481 North Frederick...

  1. SAM Radiochemical Methods Query

    EPA Pesticide Factsheets

    Laboratories measuring target radiochemical analytes in environmental samples can use this online query tool to identify analytical methods in EPA's Selected Analytical Methods for Environmental Remediation and Recovery for select radiochemical analytes.

  2. Trace analysis of multi-class pesticide residues in Chinese medicinal health wines using gas chromatography with electron capture detection

    PubMed Central

    Kong, Wei-Jun; Liu, Qiu-Tao; Kong, Dan-Dan; Liu, Qian-Zhen; Ma, Xin-Ping; Yang, Mei-Hua

    2016-01-01

    A method is described for multi-residue, high-throughput determination of trace levels of 22 organochlorine pesticides (OCPs) and 5 pyrethroid pesticides (PYPs) in Chinese medicinal (CM) health wines using a QuEChERS (quick, easy, cheap, effective, rugged, and safe) based extraction method and gas chromatography-electron capture detection (GC-ECD). Several parameters were optimized to improve preparation and separation time while still maintaining high sensitivity. Validation tests of spiked samples showed good linearities for 27 pesticides (R = 0.9909–0.9996) over wide concentration ranges. Limits of detection (LODs) and quantification (LOQs) were measured at ng/L levels, 0.06–2 ng/L and 0.2–6 ng/L for OCPs and 0.02–3 ng/L and 0.06–7 ng/L for PYPs, respectively. Inter- and intra-day precision tests showed variations of 0.65–9.89% for OCPs and 0.98–13.99% for PYPs, respectively. Average recoveries were in the range of 47.74–120.31%, with relative standard deviations below 20%. The developed method was then applied to analyze 80 CM wine samples. Beta-BHC (Benzene hexachloride) was the most frequently detected pesticide at concentration levels of 5.67–31.55 mg/L, followed by delta-BHC, trans-chlordane, gamma-BHC, and alpha-BHC. The validated method is simple and economical, with adequate sensitivity for trace levels of multi-class pesticides. It could be adopted by laboratories for this and other types of complex matrices analysis. PMID:26883080

  3. Trace analysis of multi-class pesticide residues in Chinese medicinal health wines using gas chromatography with electron capture detection

    NASA Astrophysics Data System (ADS)

    Kong, Wei-Jun; Liu, Qiu-Tao; Kong, Dan-Dan; Liu, Qian-Zhen; Ma, Xin-Ping; Yang, Mei-Hua

    2016-02-01

    A method is described for multi-residue, high-throughput determination of trace levels of 22 organochlorine pesticides (OCPs) and 5 pyrethroid pesticides (PYPs) in Chinese medicinal (CM) health wines using a QuEChERS (quick, easy, cheap, effective, rugged, and safe) based extraction method and gas chromatography-electron capture detection (GC-ECD). Several parameters were optimized to improve preparation and separation time while still maintaining high sensitivity. Validation tests of spiked samples showed good linearities for 27 pesticides (R = 0.9909-0.9996) over wide concentration ranges. Limits of detection (LODs) and quantification (LOQs) were measured at ng/L levels, 0.06-2 ng/L and 0.2-6 ng/L for OCPs and 0.02-3 ng/L and 0.06-7 ng/L for PYPs, respectively. Inter- and intra-day precision tests showed variations of 0.65-9.89% for OCPs and 0.98-13.99% for PYPs, respectively. Average recoveries were in the range of 47.74-120.31%, with relative standard deviations below 20%. The developed method was then applied to analyze 80 CM wine samples. Beta-BHC (Benzene hexachloride) was the most frequently detected pesticide at concentration levels of 5.67-31.55 mg/L, followed by delta-BHC, trans-chlordane, gamma-BHC, and alpha-BHC. The validated method is simple and economical, with adequate sensitivity for trace levels of multi-class pesticides. It could be adopted by laboratories for this and other types of complex matrices analysis.

  4. Evaluation and validation of a multi-residue method based on biochip technology for the simultaneous screening of six families of antibiotics in muscle and aquaculture products.

    PubMed

    Gaudin, Valérie; Hedou, Celine; Soumet, Christophe; Verdon, Eric

    2016-01-01

    The Evidence Investigator™ system (Randox, UK) is a biochip and semi-automated system. The microarray kit II (AM II) is capable of detecting several compounds belonging to different families of antibiotics: quinolones, ceftiofur, thiamphenicol, streptomycin, tylosin and tetracyclines. The performance of this innovative system was evaluated for the detection of antibiotic residues in new matrices, in muscle of different animal species and in aquaculture products. The method was validated according to the European Decision No. EC/2002/657 and the European guideline for the validation of screening methods, which represents a complete initial validation. The false-positive rate was equal to 0% in muscle and in aquaculture products. The detection capabilities CCβ for 12 validated antibiotics (enrofloxacin, difloxacin, ceftiofur, desfuroyl ceftiofur cysteine disulfide, thiamphenicol, florfenicol, tylosin, tilmicosin, streptomycin, dihydrostreptomycin, tetracycline, doxycycline) were all lower than the respective maximum residue limits (MRLs) in muscle from different animal origins (bovine, ovine, porcine, poultry). No cross-reactions were observed with other antibiotics, neither with the six detected families nor with other families of antibiotics. The AM II kit could be applied to aquaculture products but with higher detection capabilities from those in muscle. The detection capabilities CCβ in aquaculture products were respectively at 0.25, 0.10 and 0.5 of the respective MRL in aquaculture products for enrofloxacin, tylosin and oxytetracycline. The performance of the AM II kit has been compared with other screening methods and with the performance characteristics previously determined in honey.

  5. Screening of pesticide residues in honeybee wax comb by LC-ESI-MS/MS. A pilot study.

    PubMed

    Herrera López, Sonia; Lozano, Ana; Sosa, Alexis; Hernando, M Dolores; Fernández-Alba, Amadeo R

    2016-11-01

    A developed multi-residue method using microflow-LC-ESI-QqQ-MS provided a wide-scope analysis for medium-polar and polar pesticide residues (120 compounds including breakdown products). Honeybee wax comb samples were extracted using a generic QuEChERS based procedure. Acceptable recoveries at concentration levels of 5 and 50 μg kg(-1) were within the 70-120% range with an associated precision RSD <20%. The LOQ values were mostly 5 μg kg(-1) for almost all pesticides. Aprox. 31 of 120 LC-amenable pesticides tested (25.8%) were detected in a pilot study of 60 samples. Pesticide residues detected using the proposed method were: the breakdown products of amitraz, DMPF and DMF, an acaricide used for Varroa mite control, with a range of concentration from 5 to 464 μg kg(-1) (sum of DMPF + DMF), organophosphate insecticides from 1 to 464 μg kg(-1), acaricides at concentrations > 9 μg kg(-1); fungicides at concentrations ranging from 1 to 23 μg kg(-1.) The number of positive detections due to herbicides was lower as expected and at a lower level of concentration, from 1 to 5.9 μg kg(-1). Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Development of a rapid screening test for veterinary sedatives and the beta-blocker carazolol in porcine kidney by ELISA.

    PubMed

    Cooper, John; Delahaut, Phillippe; Fodey, Terence L; Elliott, Christopher T

    2004-02-01

    Sedatives and tranquillisers are frequently used to reduce stress during the transportation of food producing animals. The most widely used classes of sedatives include the butyrophenone azaperone, the phenothiazines acepromazine, propionylpromazine, chlorpromazine and the [small beta]-blocker, carazolol. For regulatory control purposes, tolerances for azaperone and carazolol have been set by the European Union as 100 and 25 [micro sign]g kg(-1), respectively. Furthermore, the use of the phenothiazines is prohibited and therefore has a zero tolerance. A method for the detection of residues of five tranquillisers and one [small beta]-blocker using a single ELISA plate has been developed. Kidney samples (2.5 g) were extracted with dichloromethane and applied to a competitive enzyme immunoassay using three polyclonal antibodies raised in rabbits against azaperol, propionylpromazine and carazolol conjugates. In sample matrix, the azaperol antibody cross-reacted 28.0% with azaperone and the propionylpromazine antibody cross-reacted 24.9% with acepromazine and 11.7% with chlorpromazine. In the ELISA, the detection capabilities of the six sedatives, azaperol, azaperone, carazolol, acepromazine, chlorpromazine, and propionylpromazine are 5, 15, 5, 5, 20 and 5 [micro sign]g kg(-1), respectively. The proposed method is a sensitive and rapid multi-residue technique that offers a cost effective alternative to current published procedures, without any concession on the ability to detect sedative misuse.

  7. 7 CFR 98.4 - Analytical methods.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Analytical methods. 98.4 Section 98.4 Agriculture....4 Analytical methods. (a) The majority of analytical methods used by the USDA laboratories to perform analyses of meat, meat food products and MRE's are listed as follows: (1) Official Methods of...

  8. 7 CFR 93.4 - Analytical methods.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Analytical methods. 93.4 Section 93.4 Agriculture... PROCESSED FRUITS AND VEGETABLES Citrus Juices and Certain Citrus Products § 93.4 Analytical methods. (a) The majority of analytical methods for citrus products are found in the Official Methods of Analysis of AOAC...

  9. 7 CFR 98.4 - Analytical methods.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Analytical methods. 98.4 Section 98.4 Agriculture....4 Analytical methods. (a) The majority of analytical methods used by the USDA laboratories to perform analyses of meat, meat food products and MRE's are listed as follows: (1) Official Methods of...

  10. 7 CFR 93.4 - Analytical methods.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Analytical methods. 93.4 Section 93.4 Agriculture... PROCESSED FRUITS AND VEGETABLES Citrus Juices and Certain Citrus Products § 93.4 Analytical methods. (a) The majority of analytical methods for citrus products are found in the Official Methods of Analysis of AOAC...

  11. 7 CFR 93.4 - Analytical methods.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Analytical methods. 93.4 Section 93.4 Agriculture... PROCESSED FRUITS AND VEGETABLES Citrus Juices and Certain Citrus Products § 93.4 Analytical methods. (a) The majority of analytical methods for citrus products are found in the Official Methods of Analysis of AOAC...

  12. 7 CFR 98.4 - Analytical methods.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Analytical methods. 98.4 Section 98.4 Agriculture....4 Analytical methods. (a) The majority of analytical methods used by the USDA laboratories to perform analyses of meat, meat food products and MRE's are listed as follows: (1) Official Methods of...

  13. 7 CFR 98.4 - Analytical methods.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Analytical methods. 98.4 Section 98.4 Agriculture....4 Analytical methods. (a) The majority of analytical methods used by the USDA laboratories to perform analyses of meat, meat food products and MRE's are listed as follows: (1) Official Methods of...

  14. 7 CFR 98.4 - Analytical methods.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Analytical methods. 98.4 Section 98.4 Agriculture... Analytical methods. (a) The majority of analytical methods used by the USDA laboratories to perform analyses of meat, meat food products and MREs are listed as follows: (1) Official Methods of Analysis of AOAC...

  15. 7 CFR 93.4 - Analytical methods.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Analytical methods. 93.4 Section 93.4 Agriculture... PROCESSED FRUITS AND VEGETABLES Citrus Juices and Certain Citrus Products § 93.4 Analytical methods. (a) The majority of analytical methods for citrus products are found in the Official Methods of Analysis of AOAC...

  16. 7 CFR 93.4 - Analytical methods.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Analytical methods. 93.4 Section 93.4 Agriculture... PROCESSED FRUITS AND VEGETABLES Citrus Juices and Certain Citrus Products § 93.4 Analytical methods. (a) The majority of analytical methods for citrus products are found in the Official Methods of Analysis of AOAC...

  17. 40 CFR 161.180 - Enforcement analytical method.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Enforcement analytical method. 161.180... DATA REQUIREMENTS FOR REGISTRATION OF ANTIMICROBIAL PESTICIDES Product Chemistry Data Requirements § 161.180 Enforcement analytical method. An analytical method suitable for enforcement purposes must be...

  18. 40 CFR 158.355 - Enforcement analytical method.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Enforcement analytical method. 158.355... DATA REQUIREMENTS FOR PESTICIDES Product Chemistry § 158.355 Enforcement analytical method. An analytical method suitable for enforcement purposes must be provided for each active ingredient in the...

  19. 7 CFR 94.103 - Analytical methods.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Analytical methods. 94.103 Section 94.103 Agriculture... POULTRY AND EGG PRODUCTS Voluntary Analyses of Egg Products § 94.103 Analytical methods. The analytical methods used by the Science and Technology Division laboratories to perform voluntary analyses for egg...

  20. 7 CFR 94.103 - Analytical methods.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Analytical methods. 94.103 Section 94.103 Agriculture... POULTRY AND EGG PRODUCTS Voluntary Analyses of Egg Products § 94.103 Analytical methods. The analytical methods used by the Science and Technology Division laboratories to perform voluntary analyses for egg...

  1. 7 CFR 94.103 - Analytical methods.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Analytical methods. 94.103 Section 94.103 Agriculture... POULTRY AND EGG PRODUCTS Voluntary Analyses of Egg Products § 94.103 Analytical methods. The analytical methods used by the Science and Technology Division laboratories to perform voluntary analyses for egg...

  2. 7 CFR 94.103 - Analytical methods.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Analytical methods. 94.103 Section 94.103 Agriculture... POULTRY AND EGG PRODUCTS Voluntary Analyses of Egg Products § 94.103 Analytical methods. The analytical methods used by the Science and Technology Division laboratories to perform voluntary analyses for egg...

  3. 7 CFR 94.103 - Analytical methods.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Analytical methods. 94.103 Section 94.103 Agriculture... POULTRY AND EGG PRODUCTS Voluntary Analyses of Egg Products § 94.103 Analytical methods. The analytical methods used by the Science and Technology Division laboratories to perform voluntary analyses for egg...

  4. Multi-residue determination of 47 organic compounds in water, soil, sediment and fish-Turia River as case study.

    PubMed

    Carmona, Eric; Andreu, Vicente; Picó, Yolanda

    2017-11-30

    A sensitive and reliable method based on solid-liquid extraction (SLE) using McIlvaine-Na 2 EDTA buffer (pH=4.5)-methanol and solid-phase extraction (SPE) clean up prior to ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) was applied to determine 47 organic contaminants in fish, soil and sediments. The SPE procedure to clean-up the extracts was also used as extraction method to determine these compounds in water. Recoveries ranged from 38 to 104% for all matrices with RSDs<30%. Limits of Quantification for the target compounds were in the range of 10-50ng/g for soil, 2-40ng/g for sediment, 5-30ng/g for fish and 0.3-26ng/L for water. Furthermore, the proposed method was compared to QuEChERS (widely used for environmental matrices) that involves extraction with buffered acetonitrile (pH 5.5) and dispersive SPE clean-up. The results obtained (recoveries>50% for 36 compounds in front of 9, matrix effect<20% for 31 compounds against 21, and LOQs <25ngg -1 for 38 compounds against 22) indicates that the proposed method is more efficient than QuEChERS, The method was applied to monitoring these compounds along the Turia River. In river waters, Paracetamol (175ngL -1 ), ibuprofen (153ngL -1 ) and bisphenol A (41ngL -1 ) were the compounds most frequently detected while in sediments were vildagliptin (7ngg -1 ) and metoprolol (31ngg -1 ) and in fish, bisphenol A (33ngg -1 ) or sulfamethoxazole (13ngg -1 ). Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Multiresidue determination of pesticides in crop plants by the quick, easy, cheap, effective, rugged, and safe method and ultra-high-performance liquid chromatography tandem mass spectrometry using a calibration based on a single level standard addition in the sample.

    PubMed

    Viera, Mariela S; Rizzetti, Tiele M; de Souza, Maiara P; Martins, Manoel L; Prestes, Osmar D; Adaime, Martha B; Zanella, Renato

    2017-12-01

    In this study, a QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method, optimized by a 2 3 full factorial design, was developed for the determination of 72 pesticides in plant parts of carrot, corn, melon, rice, soy, silage, tobacco, cassava, lettuce and wheat by ultra-high-performance liquid chromatographic tandem mass spectrometry (UHPLC-MS/MS). Considering the complexity of these matrices and the need of use calibration in matrix, a new calibration approach based on single level standard addition in the sample (SLSAS) was proposed in this work and compared with the matrix-matched calibration (MMC), the procedural standard calibration (PSC) and the diluted standard addition calibration (DSAC). All approaches presented satisfactory validation parameters with recoveries from 70 to 120% and relative standard deviations≤20%. SLSAS was the most practical from the evaluated approaches and proved to be an effective way of calibration. Method limit of detection were between 4.8 and 48μgkg -1 and limit of quantification were from 16 to 160μgkg -1 . Method application to different kinds of plants found residues of 20 pesticides that were quantified with z-scores values≤2 in comparison with other calibration approaches. The proposed QuEChERS method combined with UHPLC-MS/MS analysis and using an easy and effective calibration procedure presented satisfactory results for pesticide residues determination in different crop plants and is a good alternative for routine analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. 7 CFR 94.4 - Analytical methods.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Analytical methods. 94.4 Section 94.4 Agriculture... POULTRY AND EGG PRODUCTS Mandatory Analyses of Egg Products § 94.4 Analytical methods. The majority of analytical methods used by the USDA laboratories to perform mandatory analyses for egg products are listed as...

  7. 40 CFR 136.6 - Method modifications and analytical requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) GUIDELINES ESTABLISHING TEST PROCEDURES FOR THE ANALYSIS OF POLLUTANTS § 136.6 Method... person or laboratory using a test procedure (analytical method) in this part. (2) Chemistry of the method means the reagents and reactions used in a test procedure that allow determination of the analyte(s) of...

  8. 40 CFR 136.6 - Method modifications and analytical requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROGRAMS (CONTINUED) GUIDELINES ESTABLISHING TEST PROCEDURES FOR THE ANALYSIS OF POLLUTANTS § 136.6 Method... person or laboratory using a test procedure (analytical method) in this Part. (2) Chemistry of the method means the reagents and reactions used in a test procedure that allow determination of the analyte(s) of...

  9. 40 CFR 136.6 - Method modifications and analytical requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROGRAMS (CONTINUED) GUIDELINES ESTABLISHING TEST PROCEDURES FOR THE ANALYSIS OF POLLUTANTS § 136.6 Method... person or laboratory using a test procedure (analytical method) in this part. (2) Chemistry of the method means the reagents and reactions used in a test procedure that allow determination of the analyte(s) of...

  10. 40 CFR 136.6 - Method modifications and analytical requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) GUIDELINES ESTABLISHING TEST PROCEDURES FOR THE ANALYSIS OF POLLUTANTS § 136.6 Method... person or laboratory using a test procedure (analytical method) in this part. (2) Chemistry of the method means the reagents and reactions used in a test procedure that allow determination of the analyte(s) of...

  11. Considerations regarding the validation of chromatographic mass spectrometric methods for the quantification of endogenous substances in forensics.

    PubMed

    Hess, Cornelius; Sydow, Konrad; Kueting, Theresa; Kraemer, Michael; Maas, Alexandra

    2018-02-01

    The requirement for correct evaluation of forensic toxicological results in daily routine work and scientific studies is reliable analytical data based on validated methods. Validation of a method gives the analyst tools to estimate the efficacy and reliability of the analytical method. Without validation, data might be contested in court and lead to unjustified legal consequences for a defendant. Therefore, new analytical methods to be used in forensic toxicology require careful method development and validation of the final method. Until now, there are no publications on the validation of chromatographic mass spectrometric methods for the detection of endogenous substances although endogenous analytes can be important in Forensic Toxicology (alcohol consumption marker, congener alcohols, gamma hydroxy butyric acid, human insulin and C-peptide, creatinine, postmortal clinical parameters). For these analytes, conventional validation instructions cannot be followed completely. In this paper, important practical considerations in analytical method validation for endogenous substances will be discussed which may be used as guidance for scientists wishing to develop and validate analytical methods for analytes produced naturally in the human body. Especially the validation parameters calibration model, analytical limits, accuracy (bias and precision) and matrix effects and recovery have to be approached differently. Highest attention should be paid to selectivity experiments. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Evaluation of pesticide residues in fruits and vegetables from Algeria.

    PubMed

    Mebdoua, Samira; Lazali, Mohamed; Ounane, Sidi Mohamed; Tellah, Sihem; Nabi, Fahima; Ounane, Ghania

    2017-06-01

    A total of 160 samples of 13 types of fresh fruits and vegetables from domestic production and import were analysed to detect the presence of pesticide residues. Analysis was performed by multi-residual extraction followed by gas chromatography-mass spectrometry. In 42.5% of the tested samples, no residues were found and 12.5% of samples contained pesticide residues above maximum residue limits. Risk assessment for long-term exposure was done for all pesticides detected in this study. Except chlorpyrifos and lambda-cyhalothrin, exposure to pesticides from vegetables and fruits was below 1% of the acceptable daily intake. Short-term exposure assessment revealed that in seven pesticide/commodity combinations, including three pesticides (chlorpyrifos, deltamethrin and lambda-cyhalothrin), the acute reference dose had been exceeded.

  13. Organic micro-pollutants in a karst system during low and high flow periods, results of a two-year study

    NASA Astrophysics Data System (ADS)

    Reh, Roland; Licha, Tobias; Geyer, Tobias; Nödler, Karsten; Sauter, Martin

    2013-04-01

    Fifty-four different organic micro-pollutants (OMPs) including pharmaceuticals, pesticides, corrosion inhibitors and other typical wastewater compounds such as caffeine are repeatedly analyzed in approximately fifty groundwater observation points in a complex faulted and fractured carbonate aquifer system consisting of three main spring catchment areas. The study area is characterized as well by the influence of an urban area with industrial sites and waste disposals as by surrounding agricultural uses. With the applied HPLC-MS/MS method (Nödler et al., 2010), achieving method quantification limits (MQL) of 1.8 - 28 ng L-1, forty-four of the OMPs are detected in groundwater. Indicating a subsurface water divide, OMPs distinguish between the North and the South main spring areas with respect to the number of detected OMPs, OMP combinations, occurrence of special compounds like tamoxifen and concentrations of triazoles and triazines. Regarding the vertical distribution in the aquifer system upper aquifers exhibit a higher number and higher seasonal variety of OMPs than the lower aquifer and the main spring areas. In addition to triazines and triazoles the anti-epileptic drug carbamazepine and the analgesic drug phenazone are the most frequently detected compounds. The detection of the estrogen antagonist tamoxifen in a groundwater flow system is reported for the first time. Defined combinations of OMPs occur repeatedly in the same observation wells and allow to distinguish different input functions. The comparison of detection frequency with the number of prescribed doses gives information about the specific persistance of pharmaceuticals. A disused waste disposal is identified as input area for triazines. Additional input of triazines in the agricultural areas may be indicated by different fractions of atrazine and its degradation products. Due to prohibition of atrazine as herbicide since 1992 the occurrence of OMPs in the lower aquifer, solely limited to atrazine and desethylatrazine, indicates limited aquifer connections and demonstrates a residence time of several years for vertical transport into the deep aquifer. Phenazone originates also from a disused waste disposal and is showing a persistency for more than three decades under the observed redox conditions. References Nödler K, Licha T, Bester K, Sauter M. Development of a multi-residue analytical method, based on liquid chromatography-tandem mass spectrometry, for the simultaneous determination of 46 micro-contaminants in aqueous samples. Journal of Chromatography A 2010;1217(42), 6511-6521. Reh R, Licha T, Geyer T, Nödler, K.,Sauter M. Occurrence and spatial distribution of organic micro-pollutants in a complex hydrogeological karst system during low flow and high flow periods, results of a two-year study. Science of The Total Environment 2013, 443,438-445, 10.1016/j.scitotenv.2012.11.005.

  14. 21 CFR 530.22 - Safe levels and analytical methods for food-producing animals.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... analytical method; or (3) Establish a safe level based on other appropriate scientific, technical, or... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Safe levels and analytical methods for food... § 530.22 Safe levels and analytical methods for food-producing animals. (a) FDA may establish a safe...

  15. 21 CFR 530.22 - Safe levels and analytical methods for food-producing animals.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... analytical method; or (3) Establish a safe level based on other appropriate scientific, technical, or... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Safe levels and analytical methods for food... § 530.22 Safe levels and analytical methods for food-producing animals. (a) FDA may establish a safe...

  16. 21 CFR 530.22 - Safe levels and analytical methods for food-producing animals.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... analytical method; or (3) Establish a safe level based on other appropriate scientific, technical, or... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Safe levels and analytical methods for food... § 530.22 Safe levels and analytical methods for food-producing animals. (a) FDA may establish a safe...

  17. 21 CFR 530.22 - Safe levels and analytical methods for food-producing animals.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... analytical method; or (3) Establish a safe level based on other appropriate scientific, technical, or... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Safe levels and analytical methods for food... § 530.22 Safe levels and analytical methods for food-producing animals. (a) FDA may establish a safe...

  18. SAM Methods Query

    EPA Pesticide Factsheets

    Laboratories measuring target chemical, radiochemical, pathogens, and biotoxin analytes in environmental samples can use this online query tool to identify analytical methods included in EPA's Selected Analytical Methods for Environmental Remediation

  19. SAM Pathogen Methods Query

    EPA Pesticide Factsheets

    Laboratories measuring target pathogen analytes in environmental samples can use this online query tool to identify analytical methods in EPA's Selected Analytical Methods for Environmental Remediation and Recovery for select pathogens.

  20. Pesticide exposure on sloths (Bradypus variegatus and Choloepus hoffmanni) in an agricultural landscape of Northeastern Costa Rica.

    PubMed

    Pinnock Branford, Margaret Verónica; de la Cruz, Elba; Solano, Karla; Ramírez, Oscar

    2014-01-01

    Between 2005 and 2008, wild Bradypus variegatus and Choloepus hoffmanni inhabiting an agricultural landscape and captive animals from a rescue center in Northeastern Costa Rica were studied to assess exposure to pesticides. A total of 54 animals were sampled: 42 wild sloths captured at an agricultural landscape and 12 captive animals from a rescue center. Pesticides' active ingredients were determined in three sample matrices: hair, aqueous mixture (paws' wash) and cotton gauze (mouth clean) based on multi-residue gas chromatography methods. Recoveries tests ranged from 73 to 146% and relative standard deviations were less than 20% throughout all the recovery tests. Active ingredients detected in sloths samples were ametryn, chlorothalonil, chlorpyrifos, diazinon, difenoconazole, ethoprophos and thiabendazole. These active ingredients were used in intensive agricultural production for bananas, pineapples and other crops. Blood plasma cholinesterase activity (PChE) was determined by the Ellman method modified for micro plates. Enzyme activity determination was normalized to protein content in the samples according to Bradford method. Wild sloth PChE activity was similar for both species while sloths in captivity showed differences between species. Enzyme activity was significantly lower for two-toed sloths. This study showed that sloths were exposed to pesticides that caused acute and chronic effect in mammals and can also be a threat to other wildlife species. There is a need to better understand the potential effects of exposure to pesticides in sloths and other wild mammal populations, especially those threatened or endangered. More studies in this field must be carried out on the wildlife fauna inhabiting the agricultural landscape and its surroundings.

  1. 40 CFR 136.6 - Method modifications and analytical requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... person or laboratory using a test procedure (analytical method) in this Part. (2) Chemistry of the method... (analytical method) provided that the chemistry of the method or the determinative technique is not changed... prevent efficient recovery of organic pollutants and prevent the method from meeting QC requirements, the...

  2. SAM Biotoxin Methods Query

    EPA Pesticide Factsheets

    Laboratories measuring target biotoxin analytes in environmental samples can use this online query tool to identify analytical methods included in EPA's Selected Analytical Methods for Environmental Remediation and Recovery for select biotoxins.

  3. SAM Chemical Methods Query

    EPA Pesticide Factsheets

    Laboratories measuring target chemical, radiochemical, pathogens, and biotoxin analytes in environmental samples can use this online query tool to identify analytical methods in EPA's Selected Analytical Methods for Environmental Remediation and Recovery

  4. 7 CFR 91.23 - Analytical methods.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...

  5. 7 CFR 91.23 - Analytical methods.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...

  6. 7 CFR 91.23 - Analytical methods.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...

  7. Net analyte signal standard addition method (NASSAM) as a novel spectrofluorimetric and spectrophotometric technique for simultaneous determination, application to assay of melatonin and pyridoxine

    NASA Astrophysics Data System (ADS)

    Asadpour-Zeynali, Karim; Bastami, Mohammad

    2010-02-01

    In this work a new modification of the standard addition method called "net analyte signal standard addition method (NASSAM)" is presented for the simultaneous spectrofluorimetric and spectrophotometric analysis. The proposed method combines the advantages of standard addition method with those of net analyte signal concept. The method can be applied for the determination of analyte in the presence of known interferents. The accuracy of the predictions against H-point standard addition method is not dependent on the shape of the analyte and interferent spectra. The method was successfully applied to simultaneous spectrofluorimetric and spectrophotometric determination of pyridoxine (PY) and melatonin (MT) in synthetic mixtures and in a pharmaceutical formulation.

  8. Teaching Analytical Method Transfer through Developing and Validating Then Transferring Dissolution Testing Methods for Pharmaceuticals

    ERIC Educational Resources Information Center

    Kimaru, Irene; Koether, Marina; Chichester, Kimberly; Eaton, Lafayette

    2017-01-01

    Analytical method transfer (AMT) and dissolution testing are important topics required in industry that should be taught in analytical chemistry courses. Undergraduate students in senior level analytical chemistry laboratory courses at Kennesaw State University (KSU) and St. John Fisher College (SJFC) participated in development, validation, and…

  9. Analytical analysis and implementation of a low-speed high-torque permanent magnet vernier in-wheel motor for electric vehicle

    NASA Astrophysics Data System (ADS)

    Li, Jiangui; Wang, Junhua; Zhigang, Zhao; Yan, Weili

    2012-04-01

    In this paper, analytical analysis of the permanent magnet vernier (PMV) is presented. The key is to analytically solve the governing Laplacian/quasi-Poissonian field equations in the motor regions. By using the time-stepping finite element method, the analytical method is verified. Hence, the performances of the PMV machine are quantitatively compared with that of the analytical results. The analytical results agree well with the finite element method results. Finally, the experimental results are given to further show the validity of the analysis.

  10. A sample preparation method for recovering suppressed analyte ions in MALDI TOF MS.

    PubMed

    Lou, Xianwen; de Waal, Bas F M; Milroy, Lech-Gustav; van Dongen, Joost L J

    2015-05-01

    In matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS), analyte signals can be substantially suppressed by other compounds in the sample. In this technical note, we describe a modified thin-layer sample preparation method that significantly reduces the analyte suppression effect (ASE). In our method, analytes are deposited on top of the surface of matrix preloaded on the MALDI plate. To prevent embedding of analyte into the matrix crystals, the sample solution were prepared without matrix and efforts were taken not to re-dissolve the preloaded matrix. The results with model mixtures of peptides, synthetic polymers and lipids show that detection of analyte ions, which were completely suppressed using the conventional dried-droplet method, could be effectively recovered by using our method. Our findings suggest that the incorporation of analytes in the matrix crystals has an important contributory effect on ASE. By reducing ASE, our method should be useful for the direct MALDI MS analysis of multicomponent mixtures. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Human errors and measurement uncertainty

    NASA Astrophysics Data System (ADS)

    Kuselman, Ilya; Pennecchi, Francesca

    2015-04-01

    Evaluating the residual risk of human errors in a measurement and testing laboratory, remaining after the error reduction by the laboratory quality system, and quantifying the consequences of this risk for the quality of the measurement/test results are discussed based on expert judgments and Monte Carlo simulations. A procedure for evaluation of the contribution of the residual risk to the measurement uncertainty budget is proposed. Examples are provided using earlier published sets of expert judgments on human errors in pH measurement of groundwater, elemental analysis of geological samples by inductively coupled plasma mass spectrometry, and multi-residue analysis of pesticides in fruits and vegetables. The human error contribution to the measurement uncertainty budget in the examples was not negligible, yet also not dominant. This was assessed as a good risk management result.

  12. Proposal of Classification Method of Time Series Data in International Emissions Trading Market Using Agent-based Simulation

    NASA Astrophysics Data System (ADS)

    Nakada, Tomohiro; Takadama, Keiki; Watanabe, Shigeyoshi

    This paper proposes the classification method using Bayesian analytical method to classify the time series data in the international emissions trading market depend on the agent-based simulation and compares the case with Discrete Fourier transform analytical method. The purpose demonstrates the analytical methods mapping time series data such as market price. These analytical methods have revealed the following results: (1) the classification methods indicate the distance of mapping from the time series data, it is easier the understanding and inference than time series data; (2) these methods can analyze the uncertain time series data using the distance via agent-based simulation including stationary process and non-stationary process; and (3) Bayesian analytical method can show the 1% difference description of the emission reduction targets of agent.

  13. 40 CFR 141.704 - Analytical methods.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Analytical methods. 141.704 Section... Monitoring Requirements § 141.704 Analytical methods. (a) Cryptosporidium. Systems must analyze for Cryptosporidium using Method 1623: Cryptosporidium and Giardia in Water by Filtration/IMS/FA, 2005, United States...

  14. 40 CFR 141.704 - Analytical methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Analytical methods. 141.704 Section... Monitoring Requirements § 141.704 Analytical methods. (a) Cryptosporidium. Systems must analyze for Cryptosporidium using Method 1623: Cryptosporidium and Giardia in Water by Filtration/IMS/FA, 2005, United States...

  15. 40 CFR 141.704 - Analytical methods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 24 2013-07-01 2013-07-01 false Analytical methods. 141.704 Section... Monitoring Requirements § 141.704 Analytical methods. (a) Cryptosporidium. Systems must analyze for Cryptosporidium using Method 1623: Cryptosporidium and Giardia in Water by Filtration/IMS/FA, 2005, United States...

  16. 77 FR 41336 - Analytical Methods Used in Periodic Reporting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... Methods Used in Periodic Reporting AGENCY: Postal Regulatory Commission. ACTION: Notice of filing. SUMMARY... proceeding to consider changes in analytical methods used in periodic reporting. This notice addresses... informal rulemaking proceeding to consider changes in the analytical methods approved for use in periodic...

  17. 40 CFR 141.704 - Analytical methods.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Analytical methods. 141.704 Section... Monitoring Requirements § 141.704 Analytical methods. (a) Cryptosporidium. Systems must analyze for Cryptosporidium using Method 1623: Cryptosporidium and Giardia in Water by Filtration/IMS/FA, 2005, United States...

  18. 40 CFR 141.704 - Analytical methods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Analytical methods. 141.704 Section... Monitoring Requirements § 141.704 Analytical methods. (a) Cryptosporidium. Systems must analyze for Cryptosporidium using Method 1623: Cryptosporidium and Giardia in Water by Filtration/IMS/FA, 2005, United States...

  19. Recently published analytical methods for determining alcohol in body materials : alcohol countermeasures literature review

    DOT National Transportation Integrated Search

    1974-10-01

    The author has brought the review of published analytical methods for determining alcohol in body materials up-to- date. The review deals with analytical methods for alcohol in blood and other body fluids and tissues; breath alcohol methods; factors ...

  20. Dissipation kinetics of organophosphorus pesticides in milled toasted maize and wheat flour (gofio) during storage.

    PubMed

    González-Curbelo, Miguel Ángel; Socas-Rodríguez, Bárbara; Herrero, Miguel; Herrera-Herrera, Antonio V; Hernández-Borges, Javier

    2017-08-15

    The dissipation/degradation of the pesticides dimethoate, terbufos, disulfoton, and pirimiphos-methyl were evaluated in milled toasted maize and wheat flour (gofio) during three months of storage. Their dissipation kinetics and residual levels were determined, as well as their possible decomposition into some of their main transformation products (disulfoton sulfoxide, terbufos sulfone and disulfoton sulfone). For this purpose, pesticide-free milled toasted maize and wheat samples were spiked with the pesticides, and they were then stored in the darkness at ambient temperature in a closed container to simulate current storage conditions of such packed food. A multiresidue analysis based on the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method was performed for the simultaneous determination of these pesticides and their metabolites. After three months of storage, the dissipation of residues ranged between 34% (pirimiphos-methyl) and 86% (disulfoton) for maize gofio and between 69% (terbufos) and 92% (disulfoton and pirimiphos-methyl) for wheat gofio. The results demonstrated that the degradation was slower in gofio than in wheat gofio and that none of the selected metabolites were detected in any of the samples. Dissipation curves of all studied pesticides fitted to a first-order decay curve in both types of cereals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. 7 CFR 93.13 - Analytical methods.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Analytical methods. 93.13 Section 93.13 Agriculture... PROCESSED FRUITS AND VEGETABLES Peanuts, Tree Nuts, Corn and Other Oilseeds § 93.13 Analytical methods... manuals: (a) Approved Methods of the American Association of Cereal Chemists (AACC), American Association...

  2. 40 CFR 141.25 - Analytical methods for radioactivity.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Analytical methods for radioactivity... § 141.25 Analytical methods for radioactivity. (a) Analysis for the following contaminants shall be conducted to determine compliance with § 141.66 (radioactivity) in accordance with the methods in the...

  3. 7 CFR 93.13 - Analytical methods.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Analytical methods. 93.13 Section 93.13 Agriculture... PROCESSED FRUITS AND VEGETABLES Peanuts, Tree Nuts, Corn and Other Oilseeds § 93.13 Analytical methods... manuals: (a) Approved Methods of the American Association of Cereal Chemists (AACC), American Association...

  4. 7 CFR 93.13 - Analytical methods.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Analytical methods. 93.13 Section 93.13 Agriculture... PROCESSED FRUITS AND VEGETABLES Peanuts, Tree Nuts, Corn and Other Oilseeds § 93.13 Analytical methods... manuals: (a) Approved Methods of the American Association of Cereal Chemists (AACC), American Association...

  5. 7 CFR 93.13 - Analytical methods.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Analytical methods. 93.13 Section 93.13 Agriculture... PROCESSED FRUITS AND VEGETABLES Peanuts, Tree Nuts, Corn and Other Oilseeds § 93.13 Analytical methods... manuals: (a) Approved Methods of the American Association of Cereal Chemists (AACC), American Association...

  6. 7 CFR 93.13 - Analytical methods.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Analytical methods. 93.13 Section 93.13 Agriculture... PROCESSED FRUITS AND VEGETABLES Peanuts, Tree Nuts, Corn and Other Oilseeds § 93.13 Analytical methods... manuals: (a) Approved Methods of the American Association of Cereal Chemists (AACC), American Association...

  7. Generation of gas-phase ions from charged clusters: an important ionization step causing suppression of matrix and analyte ions in matrix-assisted laser desorption/ionization mass spectrometry.

    PubMed

    Lou, Xianwen; van Dongen, Joost L J; Milroy, Lech-Gustav; Meijer, E W

    2016-12-30

    Ionization in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a very complicated process. It has been reported that quaternary ammonium salts show extremely strong matrix and analyte suppression effects which cannot satisfactorily be explained by charge transfer reactions. Further investigation of the reasons causing these effects can be useful to improve our understanding of the MALDI process. The dried-droplet and modified thin-layer methods were used as sample preparation methods. In the dried-droplet method, analytes were co-crystallized with matrix, whereas in the modified thin-layer method analytes were deposited on the surface of matrix crystals. Model compounds, tetrabutylammonium iodide ([N(Bu) 4 ]I), cesium iodide (CsI), trihexylamine (THA) and polyethylene glycol 600 (PEG 600), were selected as the test analytes given their ability to generate exclusively pre-formed ions, protonated ions and metal ion adducts respectively in MALDI. The strong matrix suppression effect (MSE) observed using the dried-droplet method might disappear using the modified thin-layer method, which suggests that the incorporation of analytes in matrix crystals contributes to the MSE. By depositing analytes on the matrix surface instead of incorporating in the matrix crystals, the competition for evaporation/ionization from charged matrix/analyte clusters could be weakened resulting in reduced MSE. Further supporting evidence for this inference was found by studying the analyte suppression effect using the same two sample deposition methods. By comparing differences between the mass spectra obtained via the two sample preparation methods, we present evidence suggesting that the generation of gas-phase ions from charged matrix/analyte clusters may induce significant suppression of matrix and analyte ions. The results suggest that the generation of gas-phase ions from charged matrix/analyte clusters is an important ionization step in MALDI-MS. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Finite-analytic numerical solution of heat transfer in two-dimensional cavity flow

    NASA Technical Reports Server (NTRS)

    Chen, C.-J.; Naseri-Neshat, H.; Ho, K.-S.

    1981-01-01

    Heat transfer in cavity flow is numerically analyzed by a new numerical method called the finite-analytic method. The basic idea of the finite-analytic method is the incorporation of local analytic solutions in the numerical solutions of linear or nonlinear partial differential equations. In the present investigation, the local analytic solutions for temperature, stream function, and vorticity distributions are derived. When the local analytic solution is evaluated at a given nodal point, it gives an algebraic relationship between a nodal value in a subregion and its neighboring nodal points. A system of algebraic equations is solved to provide the numerical solution of the problem. The finite-analytic method is used to solve heat transfer in the cavity flow at high Reynolds number (1000) for Prandtl numbers of 0.1, 1, and 10.

  9. Selected Analytical Methods for Environmental Remediation and Recovery (SAM) - Home

    EPA Pesticide Factsheets

    The SAM Home page provides access to all information provided in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM), and includes a query function allowing users to search methods by analyte, sample type and instrumentation.

  10. 40 CFR 141.89 - Analytical methods.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Analytical methods. 141.89 Section 141...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Control of Lead and Copper § 141.89 Analytical methods. (a... shall be conducted with the methods in § 141.23(k)(1). (1) Analyses for alkalinity, calcium...

  11. 40 CFR 141.89 - Analytical methods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 24 2013-07-01 2013-07-01 false Analytical methods. 141.89 Section 141...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Control of Lead and Copper § 141.89 Analytical methods. (a... shall be conducted with the methods in § 141.23(k)(1). (1) Analyses for alkalinity, calcium...

  12. 40 CFR 141.89 - Analytical methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Analytical methods. 141.89 Section 141...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Control of Lead and Copper § 141.89 Analytical methods. (a... shall be conducted with the methods in § 141.23(k)(1). (1) Analyses for alkalinity, calcium...

  13. 40 CFR 141.89 - Analytical methods.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Analytical methods. 141.89 Section 141...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Control of Lead and Copper § 141.89 Analytical methods. (a... shall be conducted with the methods in § 141.23(k)(1). (1) Analyses for alkalinity, calcium...

  14. 75 FR 49930 - Stakeholder Meeting Regarding Re-Evaluation of Currently Approved Total Coliform Analytical Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-16

    ... Currently Approved Total Coliform Analytical Methods AGENCY: Environmental Protection Agency (EPA). ACTION... of currently approved Total Coliform Rule (TCR) analytical methods. At these meetings, stakeholders will be given an opportunity to discuss potential elements of a method re-evaluation study, such as...

  15. 40 CFR 141.89 - Analytical methods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Analytical methods. 141.89 Section 141...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Control of Lead and Copper § 141.89 Analytical methods. (a... shall be conducted with the methods in § 141.23(k)(1). (1) Analyses for alkalinity, calcium...

  16. A Generalized Pivotal Quantity Approach to Analytical Method Validation Based on Total Error.

    PubMed

    Yang, Harry; Zhang, Jianchun

    2015-01-01

    The primary purpose of method validation is to demonstrate that the method is fit for its intended use. Traditionally, an analytical method is deemed valid if its performance characteristics such as accuracy and precision are shown to meet prespecified acceptance criteria. However, these acceptance criteria are not directly related to the method's intended purpose, which is usually a gurantee that a high percentage of the test results of future samples will be close to their true values. Alternate "fit for purpose" acceptance criteria based on the concept of total error have been increasingly used. Such criteria allow for assessing method validity, taking into account the relationship between accuracy and precision. Although several statistical test methods have been proposed in literature to test the "fit for purpose" hypothesis, the majority of the methods are not designed to protect the risk of accepting unsuitable methods, thus having the potential to cause uncontrolled consumer's risk. In this paper, we propose a test method based on generalized pivotal quantity inference. Through simulation studies, the performance of the method is compared to five existing approaches. The results show that both the new method and the method based on β-content tolerance interval with a confidence level of 90%, hereafter referred to as the β-content (0.9) method, control Type I error and thus consumer's risk, while the other existing methods do not. It is further demonstrated that the generalized pivotal quantity method is less conservative than the β-content (0.9) method when the analytical methods are biased, whereas it is more conservative when the analytical methods are unbiased. Therefore, selection of either the generalized pivotal quantity or β-content (0.9) method for an analytical method validation depends on the accuracy of the analytical method. It is also shown that the generalized pivotal quantity method has better asymptotic properties than all of the current methods. Analytical methods are often used to ensure safety, efficacy, and quality of medicinal products. According to government regulations and regulatory guidelines, these methods need to be validated through well-designed studies to minimize the risk of accepting unsuitable methods. This article describes a novel statistical test for analytical method validation, which provides better protection for the risk of accepting unsuitable analytical methods. © PDA, Inc. 2015.

  17. 40 CFR 158.355 - Enforcement analytical method.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Enforcement analytical method. 158.355 Section 158.355 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR PESTICIDES Product Chemistry § 158.355 Enforcement analytical method. An...

  18. 40 CFR 158.355 - Enforcement analytical method.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Enforcement analytical method. 158.355 Section 158.355 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR PESTICIDES Product Chemistry § 158.355 Enforcement analytical method. An...

  19. 40 CFR 158.355 - Enforcement analytical method.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Enforcement analytical method. 158.355 Section 158.355 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR PESTICIDES Product Chemistry § 158.355 Enforcement analytical method. An...

  20. 40 CFR 158.355 - Enforcement analytical method.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Enforcement analytical method. 158.355 Section 158.355 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR PESTICIDES Product Chemistry § 158.355 Enforcement analytical method. An...

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hohimer, J.P.

    The use of laser-based analytical methods in nuclear-fuel processing plants is considered. The species and locations for accountability, process control, and effluent control measurements in the Coprocessing, Thorex, and reference Purex fuel processing operations are identified and the conventional analytical methods used for these measurements are summarized. The laser analytical methods based upon Raman, absorption, fluorescence, and nonlinear spectroscopy are reviewed and evaluated for their use in fuel processing plants. After a comparison of the capabilities of the laser-based and conventional analytical methods, the promising areas of application of the laser-based methods in fuel processing plants are identified.

  2. Rational Selection, Criticality Assessment, and Tiering of Quality Attributes and Test Methods for Analytical Similarity Evaluation of Biosimilars.

    PubMed

    Vandekerckhove, Kristof; Seidl, Andreas; Gutka, Hiten; Kumar, Manish; Gratzl, Gyöngyi; Keire, David; Coffey, Todd; Kuehne, Henriette

    2018-05-10

    Leading regulatory agencies recommend biosimilar assessment to proceed in a stepwise fashion, starting with a detailed analytical comparison of the structural and functional properties of the proposed biosimilar and reference product. The degree of analytical similarity determines the degree of residual uncertainty that must be addressed through downstream in vivo studies. Substantive evidence of similarity from comprehensive analytical testing may justify a targeted clinical development plan, and thus enable a shorter path to licensing. The importance of a careful design of the analytical similarity study program therefore should not be underestimated. Designing a state-of-the-art analytical similarity study meeting current regulatory requirements in regions such as the USA and EU requires a methodical approach, consisting of specific steps that far precede the work on the actual analytical study protocol. This white paper discusses scientific and methodological considerations on the process of attribute and test method selection, criticality assessment, and subsequent assignment of analytical measures to US FDA's three tiers of analytical similarity assessment. Case examples of selection of critical quality attributes and analytical methods for similarity exercises are provided to illustrate the practical implementation of the principles discussed.

  3. Simultaneous Spectrophotometric Determination of Rifampicin, Isoniazid and Pyrazinamide in a Single Step

    PubMed Central

    Asadpour-Zeynali, Karim; Saeb, Elhameh

    2016-01-01

    Three antituberculosis medications are investigated in this work consist of rifampicin, isoniazid and pyrazinamide. The ultra violet (UV) spectra of these compounds are overlapped, thus use of suitable chemometric methods are helpful for simultaneous spectrophotometric determination of them. A generalized version of net analyte signal standard addition method (GNASSAM) was used for determination of three antituberculosis medications as a model system. In generalized net analyte signal standard addition method only one standard solution was prepared for all analytes. This standard solution contains a mixture of all analytes of interest, and the addition of such solution to sample, causes increases in net analyte signal of each analyte which are proportional to the concentrations of analytes in added standards solution. For determination of concentration of each analyte in some synthetic mixtures, the UV spectra of pure analytes and each sample were recorded in the range of 210 nm-550 nm. The standard addition procedure was performed for each sample and the UV spectrum was recorded after each addition and finally the results were analyzed by net analyte signal method. Obtained concentrations show acceptable performance of GNASSAM in these cases. PMID:28243267

  4. Stabilizing potentials in bound state analytic continuation methods for electronic resonances in polyatomic molecules

    DOE PAGES

    White, Alec F.; Head-Gordon, Martin; McCurdy, C. William

    2017-01-30

    The computation of Siegert energies by analytic continuation of bound state energies has recently been applied to shape resonances in polyatomic molecules by several authors. Here, we critically evaluate a recently proposed analytic continuation method based on low order (type III) Padé approximants as well as an analytic continuation method based on high order (type II) Padé approximants. We compare three classes of stabilizing potentials: Coulomb potentials, Gaussian potentials, and attenuated Coulomb potentials. These methods are applied to a model potential where the correct answer is known exactly and to the 2Π g shape resonance of N 2 - whichmore » has been studied extensively by other methods. Both the choice of stabilizing potential and method of analytic continuation prove to be important to the accuracy of the results. We then conclude that an attenuated Coulomb potential is the most effective of the three for bound state analytic continuation methods. With the proper potential, such methods show promise for algorithmic determination of the positions and widths of molecular shape resonances.« less

  5. Stabilizing potentials in bound state analytic continuation methods for electronic resonances in polyatomic molecules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, Alec F.; Head-Gordon, Martin; McCurdy, C. William

    The computation of Siegert energies by analytic continuation of bound state energies has recently been applied to shape resonances in polyatomic molecules by several authors. Here, we critically evaluate a recently proposed analytic continuation method based on low order (type III) Padé approximants as well as an analytic continuation method based on high order (type II) Padé approximants. We compare three classes of stabilizing potentials: Coulomb potentials, Gaussian potentials, and attenuated Coulomb potentials. These methods are applied to a model potential where the correct answer is known exactly and to the 2Π g shape resonance of N 2 - whichmore » has been studied extensively by other methods. Both the choice of stabilizing potential and method of analytic continuation prove to be important to the accuracy of the results. We then conclude that an attenuated Coulomb potential is the most effective of the three for bound state analytic continuation methods. With the proper potential, such methods show promise for algorithmic determination of the positions and widths of molecular shape resonances.« less

  6. Method for reduction of selected ion intensities in confined ion beams

    DOEpatents

    Eiden, Gregory C.; Barinaga, Charles J.; Koppenaal, David W.

    1998-01-01

    A method for producing an ion beam having an increased proportion of analyte ions compared to carrier gas ions is disclosed. Specifically, the method has the step of addition of a charge transfer gas to the carrier analyte combination that accepts charge from the carrier gas ions yet minimally accepts charge from the analyte ions thereby selectively neutralizing the carrier gas ions. Also disclosed is the method as employed in various analytical instruments including an inductively coupled plasma mass spectrometer.

  7. Method for reduction of selected ion intensities in confined ion beams

    DOEpatents

    Eiden, G.C.; Barinaga, C.J.; Koppenaal, D.W.

    1998-06-16

    A method for producing an ion beam having an increased proportion of analyte ions compared to carrier gas ions is disclosed. Specifically, the method has the step of addition of a charge transfer gas to the carrier analyte combination that accepts charge from the carrier gas ions yet minimally accepts charge from the analyte ions thereby selectively neutralizing the carrier gas ions. Also disclosed is the method as employed in various analytical instruments including an inductively coupled plasma mass spectrometer. 7 figs.

  8. Method for Operating a Sensor to Differentiate Between Analytes in a Sample

    DOEpatents

    Kunt, Tekin; Cavicchi, Richard E; Semancik, Stephen; McAvoy, Thomas J

    1998-07-28

    Disclosed is a method for operating a sensor to differentiate between first and second analytes in a sample. The method comprises the steps of determining a input profile for the sensor which will enhance the difference in the output profiles of the sensor as between the first analyte and the second analyte; determining a first analyte output profile as observed when the input profile is applied to the sensor; determining a second analyte output profile as observed when the temperature profile is applied to the sensor; introducing the sensor to the sample while applying the temperature profile to the sensor, thereby obtaining a sample output profile; and evaluating the sample output profile as against the first and second analyte output profiles to thereby determine which of the analytes is present in the sample.

  9. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of selected carbamate pesticides in water by high-performance liquid chromatography

    USGS Publications Warehouse

    Werner, S.L.; Johnson, S.M.

    1994-01-01

    As part of its primary responsibility concerning water as a national resource, the U.S. Geological Survey collects and analyzes samples of ground water and surface water to determine water quality. This report describes the method used since June 1987 to determine selected total-recoverable carbamate pesticides present in water samples. High- performance liquid chromatography is used to separate N-methyl carbamates, N-methyl carbamoyloximes, and an N-phenyl carbamate which have been extracted from water and concentrated in dichloromethane. Analytes, surrogate compounds, and reference compounds are eluted from the analytical column within 25 minutes. Two modes of analyte detection are used: (1) a photodiode-array detector measures and records ultraviolet-absorbance profiles, and (2) a fluorescence detector measures and records fluorescence from an analyte derivative produced when analyte hydrolysis is combined with chemical derivatization. Analytes are identified and confirmed in a three-stage process by use of chromatographic retention time, ultraviolet (UV) spectral comparison, and derivatization/fluorescence detection. Quantitative results are based on the integration of single-wavelength UV-absorbance chromatograms and on comparison with calibration curves derived from external analyte standards that are run with samples as part of an instrumental analytical sequence. Estimated method detection limits vary for each analyte, depending on the sample matrix conditions, and range from 0.5 microgram per liter to as low as 0.01 microgram per liter. Reporting levels for all analytes have been set at 0.5 microgram per liter for this method. Corrections on the basis of percentage recoveries of analytes spiked into distilled water are not applied to values calculated for analyte concentration in samples. These values for analyte concentrations instead indicate the quantities recovered by the method from a particular sample matrix.

  10. Evaluation of selected methods for determining streamflow during periods of ice effect

    USGS Publications Warehouse

    Melcher, N.B.; Walker, J.F.

    1990-01-01

    The methods are classified into two general categories, subjective and analytical, depending on whether individual judgement is necessary for method application. On the basis of results of the evaluation for the three Iowa stations, two of the subjective methods (discharge ratio and hydrographic-and-climatic comparison) were more accurate than the other subjective methods, and approximately as accurate as the best analytical method. Three of the analytical methods (index velocity, adjusted rating curve, and uniform flow) could potentially be used for streamflow-gaging stations where the need for accurate ice-affected discharge estimates justifies the expense of collecting additional field data. One analytical method (ice adjustment factor) may be appropriate for use for stations with extremely stable stage-discharge ratings and measuring sections. Further research is needed to refine the analytical methods. The discharge ratio and multiple regression methods produce estimates of streamflow for varying ice conditions using information obtained from the existing U.S. Geological Survey streamflow-gaging network.

  11. PESTICIDE ANALYTICAL METHODS TO SUPPORT DUPLICATE-DIET HUMAN EXPOSURE MEASUREMENTS

    EPA Science Inventory

    Historically, analytical methods for determination of pesticides in foods have been developed in support of regulatory programs and are specific to food items or food groups. Most of the available methods have been developed, tested and validated for relatively few analytes an...

  12. Validating Analytical Methods

    ERIC Educational Resources Information Center

    Ember, Lois R.

    1977-01-01

    The procedures utilized by the Association of Official Analytical Chemists (AOAC) to develop, evaluate, and validate analytical methods for the analysis of chemical pollutants are detailed. Methods validated by AOAC are used by the EPA and FDA in their enforcement programs and are granted preferential treatment by the courts. (BT)

  13. Major advances in testing of dairy products: milk component and dairy product attribute testing.

    PubMed

    Barbano, D M; Lynch, J M

    2006-04-01

    Milk component analysis is relatively unusual in the field of quantitative analytical chemistry because an analytical test result determines the allocation of very large amounts of money between buyers and sellers of milk. Therefore, there is high incentive to develop and refine these methods to achieve a level of analytical performance rarely demanded of most methods or laboratory staff working in analytical chemistry. In the last 25 yr, well-defined statistical methods to characterize and validate analytical method performance combined with significant improvements in both the chemical and instrumental methods have allowed achievement of improved analytical performance for payment testing. A shift from marketing commodity dairy products to the development, manufacture, and marketing of value added dairy foods for specific market segments has created a need for instrumental and sensory approaches and quantitative data to support product development and marketing. Bringing together sensory data from quantitative descriptive analysis and analytical data from gas chromatography olfactometry for identification of odor-active compounds in complex natural dairy foods has enabled the sensory scientist and analytical chemist to work together to improve the consistency and quality of dairy food flavors.

  14. 77 FR 56176 - Analytical Methods Used in Periodic Reporting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-12

    ... POSTAL REGULATORY COMMISSION 39 CFR Part 3001 [Docket No. RM2012-7; Order No. 1459] Analytical Methods Used in Periodic Reporting AGENCY: Postal Regulatory Commission. ACTION: Notice of proposed... analytical methods approved for use in periodic reporting.\\1\\ \\1\\ Petition of the United States Postal...

  15. Introduction to Validation of Analytical Methods: Potentiometric Determination of CO[subscript 2

    ERIC Educational Resources Information Center

    Hipólito-Nájera, A. Ricardo; Moya-Hernandez, M. Rosario; Gomez-Balderas, Rodolfo; Rojas-Hernandez, Alberto; Romero-Romo, Mario

    2017-01-01

    Validation of analytical methods is a fundamental subject for chemical analysts working in chemical industries. These methods are also relevant for pharmaceutical enterprises, biotechnology firms, analytical service laboratories, government departments, and regulatory agencies. Therefore, for undergraduate students enrolled in majors in the field…

  16. External Standards or Standard Addition? Selecting and Validating a Method of Standardization

    NASA Astrophysics Data System (ADS)

    Harvey, David T.

    2002-05-01

    A common feature of many problem-based laboratories in analytical chemistry is a lengthy independent project involving the analysis of "real-world" samples. Students research the literature, adapting and developing a method suitable for their analyte, sample matrix, and problem scenario. Because these projects encompass the complete analytical process, students must consider issues such as obtaining a representative sample, selecting a method of analysis, developing a suitable standardization, validating results, and implementing appropriate quality assessment/quality control practices. Most textbooks and monographs suitable for an undergraduate course in analytical chemistry, however, provide only limited coverage of these important topics. The need for short laboratory experiments emphasizing important facets of method development, such as selecting a method of standardization, is evident. The experiment reported here, which is suitable for an introductory course in analytical chemistry, illustrates the importance of matrix effects when selecting a method of standardization. Students also learn how a spike recovery is used to validate an analytical method, and obtain a practical experience in the difference between performing an external standardization and a standard addition.

  17. No Impact of the Analytical Method Used for Determining Cystatin C on Estimating Glomerular Filtration Rate in Children.

    PubMed

    Alberer, Martin; Hoefele, Julia; Benz, Marcus R; Bökenkamp, Arend; Weber, Lutz T

    2017-01-01

    Measurement of inulin clearance is considered to be the gold standard for determining kidney function in children, but this method is time consuming and expensive. The glomerular filtration rate (GFR) is on the other hand easier to calculate by using various creatinine- and/or cystatin C (Cys C)-based formulas. However, for the determination of serum creatinine (Scr) and Cys C, different and non-interchangeable analytical methods exist. Given the fact that different analytical methods for the determination of creatinine and Cys C were used in order to validate existing GFR formulas, clinicians should be aware of the type used in their local laboratory. In this study, we compared GFR results calculated on the basis of different GFR formulas and either used Scr and Cys C values as determined by the analytical method originally employed for validation or values obtained by an alternative analytical method to evaluate any possible effects on the performance. Cys C values determined by means of an immunoturbidimetric assay were used for calculating the GFR using equations in which this analytical method had originally been used for validation. Additionally, these same values were then used in other GFR formulas that had originally been validated using a nephelometric immunoassay for determining Cys C. The effect of using either the compatible or the possibly incompatible analytical method for determining Cys C in the calculation of GFR was assessed in comparison with the GFR measured by creatinine clearance (CrCl). Unexpectedly, using GFR equations that employed Cys C values derived from a possibly incompatible analytical method did not result in a significant difference concerning the classification of patients as having normal or reduced GFR compared to the classification obtained on the basis of CrCl. Sensitivity and specificity were adequate. On the other hand, formulas using Cys C values derived from a compatible analytical method partly showed insufficient performance when compared to CrCl. Although clinicians should be aware of applying a GFR formula that is compatible with the locally used analytical method for determining Cys C and creatinine, other factors might be more crucial for the calculation of correct GFR values.

  18. Single solid phase extraction method for the simultaneous analysis of polar and non-polar pesticides in urine samples by gas chromatography and ultra high pressure liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Cazorla-Reyes, Rocío; Fernández-Moreno, José Luis; Romero-González, Roberto; Frenich, Antonia Garrido; Vidal, José Luis Martínez

    2011-07-15

    A new multiresidue method has been developed and validated for the simultaneous extraction of more than two hundred pesticides, including non-polar and polar pesticides (carbamates, organochlorine, organophosphorous, pyrethroids, herbicides and insecticides) in urine at trace levels by gas and ultra high pressure liquid chromatography coupled to ion trap and triple quadrupole mass spectrometry, respectively (GC-IT-MS/MS, UHPLC-QqQ-MS/MS). Non-polar and polar pesticides were simultaneously extracted from urine samples by a simple and fast solid phase extraction (SPE) procedure using C(18) cartridges as sorbent, and dichloromethane as elution solvent. Recovery was in the range of 60-120%. Precision values expressed as relative standard deviation (RSD) were lower than 25%. Identification and confirmation of the compounds were performed by the use of retention time windows, comparison of spectra (GC-amenable compounds) or the estimation of the ion ratio (LC-amenable compounds). For GC-amenable pesticides, limits of detection (LODs) ranged from 0.001 to 0.436 μg L(-1) and limits of quantification (LOQs) from 0.003 to 1.452 μg L(-1). For LC-amenable pesticides, LODs ranged from 0.003 to 1.048 μg L(-1) and LOQs ranged from 0.011 to 3.494 μg L(-1). Finally, the optimized method was applied to the analysis of fourteen real samples of infants from agricultural population. Some pesticides such as methoxyfenozide, tebufenozide, piperonyl butoxide and propoxur were found at concentrations ranged from 1.61 to 24.4 μg L(-1), whereas methiocarb sulfoxide was detected at trace levels in two samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Liquid chromatography mass spectrometry determination of perfluoroalkyl acids in environmental solid extracts after phospholipid removal and on-line turbulent flow chromatography purification.

    PubMed

    Mazzoni, M; Polesello, S; Rusconi, M; Valsecchi, S

    2016-07-01

    An on-line TFC (Turbulent Flow Chromatography) clean up procedures coupled with UHPLC-MS/MS (Ultra High Performance Liquid Chromatography Mass Spectrometry) multi-residue method was developed for the simultaneous determination of 8 perfluroalkyl carboxylic acids (PFCA, from 5 to 12 carbon atoms) and 3 perfluoroalkyl sulfonic acids (PFSA, from 4 to 8 carbon atoms) in environmental solid matrices. Fast sample preparation procedure was based on a sonication-assisted extraction with acetonitrile. Phospholipids in biological samples were fully removed by an off-line SPE purification before injection, using HybridSPE(®) Phospholipid Ultra cartridges. The development of the on-line TFC clean-up procedure regarded the choice of the stationary phase, the optimization of the mobile phase composition, flow rate and injected volume. The validation of the optimized method included the evaluation of matrix effects, accuracy and reproducibility. Signal suppression in the analysis of fortified extracts ranged from 1 to 60%, and this problem was overcome by using isotopic dilution. Since no certified reference materials were available for PFAS in these matrices, accuracy was evaluated by recoveries on spiked clam samples which were 98-133% for PFCAs and 40-60% for PFSAs. MLDs and MLQs ranged from 0.03 to 0.3ngg(-1) wet weight and from 0.1 to 0.9ngg(-1) wet weight respectively. Repeatability (intra-day precision) and reproducibility (inter-day precision) showed RSD from 3 to 13% and from 4 to 27% respectively. Validated on-line TFC/UHPLC-MS/MS method has been applied for the determination of perfluoroalkyl acids in different solid matrices (sediment, fish, bivalves and bird yolk). Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Ultratrace analysis of nine macrolides, including tulathromycin A (Draxxin), in edible animal tissues with minicolumn liquid chromatography tandem mass spectrometry.

    PubMed

    Martos, Perry A; Lehotay, Steven J; Shurmer, Bryn

    2008-10-08

    The analysis of nine macrolides is presented, including tulathromycin A (Draxxin), in beef, poultry, and pork muscle with a simple multiresidue extraction and analysis method using high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The sample preparation method involves extraction with acetonitrile and defatting with hexane followed by dilution of the extracts for analysis. Separation of the nine macrolides was performed using an Atlantis dC 18, 3 mum, 3.9 mm x 20 mm minicolumn (guard column). Detection was carried out with two multiple reaction monitoring experiments per macrolide. The method detection limits (MDLs) were based on three times standard deviation of eight repeat spikes at 3.0 ng/g of a mix of the nine macrolides in the various tissues. The MDLs and retention times for the macrolides were as follows: lincomycin, 0.19 ng/g (t R = 5.00 min); tulathromycin, 0.46 ng/g (t R = 5.63 min); spiramycin, 0.21 ng/g (t R = 6.06 min); pirlimycin, 0.10 ng/g (t R = 6.04 min); clindamycin, 0.16 ng/g (t R = 6.20 min); tilmicosin, 0.29 ng/g (t R = 6.38 min); erythromycin, 0.19 ng/g (t R = 6.62 min); tylosin, 0.10 ng/g (t R = 6.72 min); and josamycin, 0.09 ng/g (t R = 6.98 min). Precision at 25 ng/g (n = 4) ranged from 2.3 to 9.4% for the compounds from beef muscle. Of interest is the detection of incurred residues of tulathromycin A in edible calf tissue at 0.10-7 mug/g, which is presented here for the first time.

  1. Surrogate matrix and surrogate analyte approaches for definitive quantitation of endogenous biomolecules.

    PubMed

    Jones, Barry R; Schultz, Gary A; Eckstein, James A; Ackermann, Bradley L

    2012-10-01

    Quantitation of biomarkers by LC-MS/MS is complicated by the presence of endogenous analytes. This challenge is most commonly overcome by calibration using an authentic standard spiked into a surrogate matrix devoid of the target analyte. A second approach involves use of a stable-isotope-labeled standard as a surrogate analyte to allow calibration in the actual biological matrix. For both methods, parallelism between calibration standards and the target analyte in biological matrix must be demonstrated in order to ensure accurate quantitation. In this communication, the surrogate matrix and surrogate analyte approaches are compared for the analysis of five amino acids in human plasma: alanine, valine, methionine, leucine and isoleucine. In addition, methodology based on standard addition is introduced, which enables a robust examination of parallelism in both surrogate analyte and surrogate matrix methods prior to formal validation. Results from additional assays are presented to introduce the standard-addition methodology and to highlight the strengths and weaknesses of each approach. For the analysis of amino acids in human plasma, comparable precision and accuracy were obtained by the surrogate matrix and surrogate analyte methods. Both assays were well within tolerances prescribed by regulatory guidance for validation of xenobiotic assays. When stable-isotope-labeled standards are readily available, the surrogate analyte approach allows for facile method development. By comparison, the surrogate matrix method requires greater up-front method development; however, this deficit is offset by the long-term advantage of simplified sample analysis.

  2. Effect-Based Screening Methods for Water Quality Characterization Will Augment Conventional Analyte-by-Analyte Chemical Methods in Research As Well As Regulatory Monitoring

    EPA Science Inventory

    Conventional approaches to water quality characterization can provide data on individual chemical components of each water sample. This analyte-by-analyte approach currently serves many useful research and compliance monitoring needs. However these approaches, which require a ...

  3. Method of multiplexed analysis using ion mobility spectrometer

    DOEpatents

    Belov, Mikhail E [Richland, WA; Smith, Richard D [Richland, WA

    2009-06-02

    A method for analyzing analytes from a sample introduced into a Spectrometer by generating a pseudo random sequence of a modulation bins, organizing each modulation bin as a series of submodulation bins, thereby forming an extended pseudo random sequence of submodulation bins, releasing the analytes in a series of analyte packets into a Spectrometer, thereby generating an unknown original ion signal vector, detecting the analytes at a detector, and characterizing the sample using the plurality of analyte signal subvectors. The method is advantageously applied to an Ion Mobility Spectrometer, and an Ion Mobility Spectrometer interfaced with a Time of Flight Mass Spectrometer.

  4. The importance of quality control in validating concentrations ...

    EPA Pesticide Factsheets

    A national-scale survey of 247 contaminants of emerging concern (CECs), including organic and inorganic chemical compounds, and microbial contaminants, was conducted in source and treated drinking water samples from 25 treatment plants across the United States. Multiple methods were used to determine these CECs, including six analytical methods to measure 174 pharmaceuticals, personal care products, and pesticides. A three-component quality assurance/quality control (QA/QC) program was designed for the subset of 174 CECs which allowed us to assess and compare performances of the methods used. The three components included: 1) a common field QA/QC protocol and sample design, 2) individual investigator-developed method-specific QA/QC protocols, and 3) a suite of 46 method comparison analytes that were determined in two or more analytical methods. Overall method performance for the 174 organic chemical CECs was assessed by comparing spiked recoveries in reagent, source, and treated water over a two-year period. In addition to the 247 CECs reported in the larger drinking water study, another 48 pharmaceutical compounds measured did not consistently meet predetermined quality standards. Methodologies that did not seem suitable for these analytes are overviewed. The need to exclude analytes based on method performance demonstrates the importance of additional QA/QC protocols. This paper compares the method performance of six analytical methods used to measure 174 emer

  5. Exhaled breath condensate – from an analytical point of view

    PubMed Central

    Dodig, Slavica; Čepelak, Ivana

    2013-01-01

    Over the past three decades, the goal of many researchers is analysis of exhaled breath condensate (EBC) as noninvasively obtained sample. A total quality in laboratory diagnostic processes in EBC analysis was investigated: pre-analytical (formation, collection, storage of EBC), analytical (sensitivity of applied methods, standardization) and post-analytical (interpretation of results) phases. EBC analysis is still used as a research tool. Limitations referred to pre-analytical, analytical, and post-analytical phases of EBC analysis are numerous, e.g. low concentrations of EBC constituents, single-analyte methods lack in sensitivity, and multi-analyte has not been fully explored, and reference values are not established. When all, pre-analytical, analytical and post-analytical requirements are met, EBC biomarkers as well as biomarker patterns can be selected and EBC analysis can hopefully be used in clinical practice, in both, the diagnosis and in the longitudinal follow-up of patients, resulting in better outcome of disease. PMID:24266297

  6. Life cycle management of analytical methods.

    PubMed

    Parr, Maria Kristina; Schmidt, Alexander H

    2018-01-05

    In modern process management, the life cycle concept gains more and more importance. It focusses on the total costs of the process from invest to operation and finally retirement. Also for analytical procedures an increasing interest for this concept exists in the recent years. The life cycle of an analytical method consists of design, development, validation (including instrumental qualification, continuous method performance verification and method transfer) and finally retirement of the method. It appears, that also regulatory bodies have increased their awareness on life cycle management for analytical methods. Thus, the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH), as well as the United States Pharmacopeial Forum discuss the enrollment of new guidelines that include life cycle management of analytical methods. The US Pharmacopeia (USP) Validation and Verification expert panel already proposed a new General Chapter 〈1220〉 "The Analytical Procedure Lifecycle" for integration into USP. Furthermore, also in the non-regulated environment a growing interest on life cycle management is seen. Quality-by-design based method development results in increased method robustness. Thereby a decreased effort is needed for method performance verification, and post-approval changes as well as minimized risk of method related out-of-specification results. This strongly contributes to reduced costs of the method during its life cycle. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Horizontal lifelines - review of regulations and simple design method considering anchorage rigidity.

    PubMed

    Galy, Bertrand; Lan, André

    2018-03-01

    Among the many occupational risks construction workers encounter every day falling from a height is the most dangerous. The objective of this article is to propose a simple analytical design method for horizontal lifelines (HLLs) that considers anchorage flexibility. The article presents a short review of the standards and regulations/acts/codes concerning HLLs in Canada the USA and Europe. A static analytical approach is proposed considering anchorage flexibility. The analytical results are compared with a series of 42 dynamic fall tests and a SAP2000 numerical model. The experimental results show that the analytical method is a little conservative and overestimates the line tension in most cases with a maximum of 17%. The static SAP2000 results show a maximum 2.1% difference with the analytical method. The analytical method is accurate enough to safely design HLLs and quick design abaci are provided to allow the engineer to make quick on-site verification if needed.

  8. IMMUNOCHEMICAL APPLICATIONS IN ENVIRONMENTAL SCIENCE

    EPA Science Inventory

    Immunochemical methods are based on selective antibodies combining with a particular target analyte or analyte group. The specific binding between antibody and analyte can be used to detect environmental contaminants in a variety of sample matrixes. Immunoassay methods provide ...

  9. Improving the efficiency of quantitative (1)H NMR: an innovative external standard-internal reference approach.

    PubMed

    Huang, Yande; Su, Bao-Ning; Ye, Qingmei; Palaniswamy, Venkatapuram A; Bolgar, Mark S; Raglione, Thomas V

    2014-01-01

    The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Multiresidue determination of pesticides in malt beverages by capillary gas chromatography with mass spectrometry and selected ion monitoring.

    PubMed

    Wong, Jon W; Webster, Michael G; Bezabeh, Dawit Z; Hengel, Mathew J; Ngim, Kenley K; Krynitsky, Alexander J; Ebeler, Susan E

    2004-10-20

    A method was developed to determine pesticides in malt beverages using solid phase extraction on a polymeric cartridge and sample cleanup with a MgSO4-topped aminopropyl cartridge, followed by capillary gas chromatography with electron impact mass spectrometry in the selected ion monitoring mode [GC-MS(SIM)]. Three GC injections were required to analyze and identify organophosphate, organohalogen, and organonitrogen pesticides. The pesticides were identified by the retention times of peaks of the target ion and qualifier-to-target ion ratios. GC detection limits for most of the pesticides were 5-10 ng/mL, and linearity was determined from 50 to 5000 ng/mL. Fortification studies were performed at 10 ng/mL for three malt beverages that differ in properties such as alcohol content, solids, and appearance. The recoveries from the three malt beverages were greater than 70% for 85 of the 142 pesticides (including isomers) studied. The data showed that the different malt beverage matrixes had no significant effect on the recoveries. This method was then applied to the screening and analysis of malt beverages for pesticides, resulting in the detection of the insectide carbaryl and the fungicide dimethomorph in real samples. The study indicates that pesticide levels in malt beverages are significantly lower than the tolerance levels set by the United States Environmental Protection Agency for malt beverage starting ingredients. The use of the extraction/cleanup procedure and analysis by GC-MS(SIM) proved effective in screening malt beverages for a wide variety of pesticides. Copyright 2004 American Chemical Society

  11. Pre-analytical and analytical variation of drug determination in segmented hair using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe; Linnet, Kristian

    2014-01-01

    Assessment of total uncertainty of analytical methods for the measurements of drugs in human hair has mainly been derived from the analytical variation. However, in hair analysis several other sources of uncertainty will contribute to the total uncertainty. Particularly, in segmental hair analysis pre-analytical variations associated with the sampling and segmentation may be significant factors in the assessment of the total uncertainty budget. The aim of this study was to develop and validate a method for the analysis of 31 common drugs in hair using ultra-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) with focus on the assessment of both the analytical and pre-analytical sampling variations. The validated method was specific, accurate (80-120%), and precise (CV≤20%) across a wide linear concentration range from 0.025-25 ng/mg for most compounds. The analytical variation was estimated to be less than 15% for almost all compounds. The method was successfully applied to 25 segmented hair specimens from deceased drug addicts showing a broad pattern of poly-drug use. The pre-analytical sampling variation was estimated from the genuine duplicate measurements of two bundles of hair collected from each subject after subtraction of the analytical component. For the most frequently detected analytes, the pre-analytical variation was estimated to be 26-69%. Thus, the pre-analytical variation was 3-7 folds larger than the analytical variation (7-13%) and hence the dominant component in the total variation (29-70%). The present study demonstrated the importance of including the pre-analytical variation in the assessment of the total uncertainty budget and in the setting of the 95%-uncertainty interval (±2CVT). Excluding the pre-analytical sampling variation could significantly affect the interpretation of results from segmental hair analysis. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. Updates to Selected Analytical Methods for Environmental Remediation and Recovery (SAM)

    EPA Pesticide Factsheets

    View information on the latest updates to methods included in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM), including the newest recommended methods and publications.

  13. Method of identity analyte-binding peptides

    DOEpatents

    Kauvar, Lawrence M.

    1990-01-01

    A method for affinity chromatography or adsorption of a designated analyte utilizes a paralog as the affinity partner. The immobilized paralog can be used in purification or analysis of the analyte; the paralog can also be used as a substitute for antibody in an immunoassay. The paralog is identified by screening candidate peptide sequences of 4-20 amino acids for specific affinity to the analyte.

  14. Approximated analytical solution to an Ebola optimal control problem

    NASA Astrophysics Data System (ADS)

    Hincapié-Palacio, Doracelly; Ospina, Juan; Torres, Delfim F. M.

    2016-11-01

    An analytical expression for the optimal control of an Ebola problem is obtained. The analytical solution is found as a first-order approximation to the Pontryagin Maximum Principle via the Euler-Lagrange equation. An implementation of the method is given using the computer algebra system Maple. Our analytical solutions confirm the results recently reported in the literature using numerical methods.

  15. Analytical method for determining rill detachment rate of purple soil as compared with that of loess soil

    USDA-ARS?s Scientific Manuscript database

    Rill detachment is an important process in rill erosion. The rill detachment rate is the fundamental basis for determination of the parameters of a rill erosion model. In this paper, an analytical method was proposed to estimate the rill detachment rate. The method is based on the exact analytical s...

  16. Sol-Gel Matrices For Direct Colorimetric Detection Of Analytes

    DOEpatents

    Charych, Deborah H.; Sasaki, Darryl; Yamanaka, Stacey

    2002-11-26

    The present invention relates to methods and compositions for the direct detection of analytes using color changes that occur in immobilized biopolymeric material in response to selective binding of analytes to their surface. In particular, the present invention provides methods and compositions related to the encapsulation of biopolymeric material into metal oxide glass using the sol-gel method.

  17. Sol-gel matrices for direct colorimetric detection of analytes

    DOEpatents

    Charych, Deborah H.; Sasaki, Darryl; Yamanaka, Stacey

    2000-01-01

    The present invention relates to methods and compositions for the direct detection of analytes using color changes that occur in immobilized biopolymeric material in response to selective binding of analytes to their surface. In particular, the present invention provides methods and compositions related to the encapsulation of biopolymeric material into metal oxide glass using the sol-gel method.

  18. Basic Information for EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM)

    EPA Pesticide Factsheets

    Contains basic information on the role and origins of the Selected Analytical Methods including the formation of the Homeland Security Laboratory Capacity Work Group and the Environmental Evaluation Analytical Process Roadmap for Homeland Security Events

  19. High resolution x-ray CMT: Reconstruction methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, J.K.

    This paper qualitatively discusses the primary characteristics of methods for reconstructing tomographic images from a set of projections. These reconstruction methods can be categorized as either {open_quotes}analytic{close_quotes} or {open_quotes}iterative{close_quotes} techniques. Analytic algorithms are derived from the formal inversion of equations describing the imaging process, while iterative algorithms incorporate a model of the imaging process and provide a mechanism to iteratively improve image estimates. Analytic reconstruction algorithms are typically computationally more efficient than iterative methods; however, analytic algorithms are available for a relatively limited set of imaging geometries and situations. Thus, the framework of iterative reconstruction methods is better suited formore » high accuracy, tomographic reconstruction codes.« less

  20. Valid analytical performance specifications for combined analytical bias and imprecision for the use of common reference intervals.

    PubMed

    Hyltoft Petersen, Per; Lund, Flemming; Fraser, Callum G; Sandberg, Sverre; Sölétormos, György

    2018-01-01

    Background Many clinical decisions are based on comparison of patient results with reference intervals. Therefore, an estimation of the analytical performance specifications for the quality that would be required to allow sharing common reference intervals is needed. The International Federation of Clinical Chemistry (IFCC) recommended a minimum of 120 reference individuals to establish reference intervals. This number implies a certain level of quality, which could then be used for defining analytical performance specifications as the maximum combination of analytical bias and imprecision required for sharing common reference intervals, the aim of this investigation. Methods Two methods were investigated for defining the maximum combination of analytical bias and imprecision that would give the same quality of common reference intervals as the IFCC recommendation. Method 1 is based on a formula for the combination of analytical bias and imprecision and Method 2 is based on the Microsoft Excel formula NORMINV including the fractional probability of reference individuals outside each limit and the Gaussian variables of mean and standard deviation. The combinations of normalized bias and imprecision are illustrated for both methods. The formulae are identical for Gaussian and log-Gaussian distributions. Results Method 2 gives the correct results with a constant percentage of 4.4% for all combinations of bias and imprecision. Conclusion The Microsoft Excel formula NORMINV is useful for the estimation of analytical performance specifications for both Gaussian and log-Gaussian distributions of reference intervals.

  1. Statistically qualified neuro-analytic failure detection method and system

    DOEpatents

    Vilim, Richard B.; Garcia, Humberto E.; Chen, Frederick W.

    2002-03-02

    An apparatus and method for monitoring a process involve development and application of a statistically qualified neuro-analytic (SQNA) model to accurately and reliably identify process change. The development of the SQNA model is accomplished in two stages: deterministic model adaption and stochastic model modification of the deterministic model adaptation. Deterministic model adaption involves formulating an analytic model of the process representing known process characteristics, augmenting the analytic model with a neural network that captures unknown process characteristics, and training the resulting neuro-analytic model by adjusting the neural network weights according to a unique scaled equation error minimization technique. Stochastic model modification involves qualifying any remaining uncertainty in the trained neuro-analytic model by formulating a likelihood function, given an error propagation equation, for computing the probability that the neuro-analytic model generates measured process output. Preferably, the developed SQNA model is validated using known sequential probability ratio tests and applied to the process as an on-line monitoring system. Illustrative of the method and apparatus, the method is applied to a peristaltic pump system.

  2. The Use and Abuse of Limits of Detection in Environmental Analytical Chemistry

    PubMed Central

    Brown, Richard J. C.

    2008-01-01

    The limit of detection (LoD) serves as an important method performance measure that is useful for the comparison of measurement techniques and the assessment of likely signal to noise performance, especially in environmental analytical chemistry. However, the LoD is only truly related to the precision characteristics of the analytical instrument employed for the analysis and the content of analyte in the blank sample. This article discusses how other criteria, such as sampling volume, can serve to distort the quoted LoD artificially and make comparison between various analytical methods inequitable. In order to compare LoDs between methods properly, it is necessary to state clearly all of the input parameters relating to the measurements that have been used in the calculation of the LoD. Additionally, the article discusses that the use of LoDs in contexts other than the comparison of the attributes of analytical methods, in particular when reporting analytical results, may be confusing, less informative than quoting the actual result with an accompanying statement of uncertainty, and may act to bias descriptive statistics. PMID:18690384

  3. Methods for determination of radioactive substances in water and fluvial sediments

    USGS Publications Warehouse

    Thatcher, Leland Lincoln; Janzer, Victor J.; Edwards, Kenneth W.

    1977-01-01

    Analytical methods for the determination of some of the more important components of fission or neutron activation product radioactivity and of natural radioactivity found in water are reported. The report for each analytical method includes conditions for application of the method, a summary of the method, interferences, required apparatus and reagents, analytical procedures, calculations, reporting of results, and estimation of precision. The fission product isotopes considered are cesium-137, strontium-90, and ruthenium-106. The natural radioelements and isotopes considered are uranium, lead-210, radium-226, radium-228, tritium, and carbon-14. A gross radioactivity survey method and a uranium isotope ratio method are given. When two analytical methods are in routine use for an individual isotope, both methods are reported with identification of the specific areas of application of each. Techniques for the collection and preservation of water samples to be analyzed for radioactivity are discussed.

  4. Simultaneous determination of aditoprim and its three major metabolites in pigs, broilers and carp tissues, and its application in tissue distribution and depletion studies.

    PubMed

    Wang, Liye; Huang, Lingli; Pan, Yuanhu; Wu, Qinghua; Xie, Shuyu; Yuan, Zonghui

    2016-08-01

    Aditoprim (ADP) is a recently developed dihydrofolate reductase inhibitor that has shown promise for therapeutic use in veterinary medicine because of its excellent pharmacokinetic properties. In this study, a sensitive and reliable multi-residue chromatography-ultraviolet (HPLC-UV) method for the quantitative analysis of ADP and its three major metabolites was developed, and the tissue distribution and depletion profiles of ADP and its major metabolites in pigs, broilers and carp were investigated. Edible and additional tissues (heart, lung, stomach, intestine and swim bladder) were collected for analysis at six different withdrawal periods after ADP administration for 7 days. ADP, N-monomethyl-ADP and N-didesmethyl-ADP were detected in almost all tissues in the three species. The liver, kidney and lung showed higher residue concentrations, and the liver showed a longer residue half-life (t1/2) than other tissues. In the liver, ADP was the most abundant component with the longest persistence. The results suggest that the liver was the residual target tissue and ADP was the marker residue, and the conclusive withdrawal time (WDT) of 20 days in pigs, 16 days in broilers and 25 days in carp was estimated using the assessment methodologies approved by the Joint FAO/WHO Expert Committee on Food Additives (JECFA).

  5. Studies of pesticide residues in tomatoes and cucumbers from Kazakhstan and the associated health risks.

    PubMed

    Lozowicka, Bozena; Abzeitova, Elmira; Sagitov, Abai; Kaczynski, Piotr; Toleubayev, Kazbek; Li, Alina

    2015-10-01

    The aim of the present study was to assess the level of pesticide residues in vegetables in the Almaty Region of Kazakhstan and to determine the potential health risks associated with the exposures to these pesticides. A total of 82 samples of cucumbers and tomatoes from top agro-based market and greenhouses were analysed using a gas chromatography-micro electron capture detector/nitrogen-phosphorous detector (GC-μECD/NPD), a multiresidue method to analyse 184 different pesticide types. The results indicated that more than half of samples (59 %) contained 29 pesticides, in which 10 are not registered in Kazakhstan, ranging from 0.01 to 0.88 mg kg(-1), and 28 % contained pesticide residues above maximum residue levels (MRLs). The estimated daily intakes (EDIs) ranged from 0.01 % of the acceptable daily intake (ADI) for pyrimethanil to 12.05 % of the ADI for lambda-cyhalothrin. The most critical commodity is triazophos and flusilazole in tomatoes, contributing 70.8 and 42.5 % to the acute hazard index (aHI). The results provided important information on the current pesticide contamination status of two commonly consumed vegetables and pointed an urgent need to control the use of plant protection products applied, especially potentially persistent pesticides, such as endosulfan and dicofol. These results also show that the detected pesticides may be considered a public health problem.

  6. Determination and occurrence of phthalates, alkylphenols, bisphenol A, PBDEs, PCBs and PAHs in an industrial sewage grid discharging to a Municipal Wastewater Treatment Plant.

    PubMed

    Sánchez-Avila, Juan; Bonet, Jordi; Velasco, Gemma; Lacorte, Silvia

    2009-06-15

    Industrial and urban discharges release organic contaminants which might affect the quality of receiving waters if not properly eliminated in Wastewater Treatment Plants (WWTP). This study is aimed to evaluate the source, transport and fate of contaminants of industrial origin in a sewage grid discharging to a WWTP and finally to the sea. The sampling network covered an industrial and urban area and wastewaters, influents and effluents of a WWTP were analyzed using a newly developed multiresidual method to capture a wide range contaminants (phthalates, alkylphenols, bisphenol A, PBDEs, PCBs and PAHs). Alkylphenols and phthalates followed by PAHs were the main compounds detected at levels between 0.01 to 698 microg l(-1) in the sewage pipelines. At the WWTP influent they were detected at concentrations up to 345 microg l(-1). The contaminant load was eliminated in a 64-92% during the primary and secondary treatment of the plant. However, alkylphenols, phthalates bisphenol A and traces of PAHs were discharged with the effluent, producing a total net input of 825 g d(-1) to the sea. The study of wastewaters herein proposed can be used to better predict the loads into WWTP to improve treatment conditions according to specific sewage inputs and to assess the risks associated with the continuous discharge of contaminants to receiving plants.

  7. Status and effect of pesticide residues in soils under different land uses of Andaman Islands, India.

    PubMed

    Murugan, A V; Swarnam, T P; Gnanasambandan, S

    2013-10-01

    Pesticides are shown to have a great effect on soil organisms, but the effect varies with pesticide group and concentration, and is modified by soil organic carbon content and soil texture. In the humid tropical islands of Andaman, India, no systematic study was carried out on pesticide residues in soils of different land uses. The present study used the modified QuEChERS method for multiresidue extraction from soils and detection with a gas chromatograph. DDT and its various metabolites, α-endosulfan, β-endosulfan, endosulfan sulfate, aldrin, and fenvalerate, were detected from the study area. Among the different pesticide groups detected, endosulfan and DDT accounted for 41.7 % each followed by aldrin (16.7 %) and synthetic pyrethroid (8.3 %). A significantly higher concentration of pesticide residues was detected in rice-vegetable grown in the valley followed by rice-fallow and vegetable-fallow in the coastal plains. Soil microbial biomass carbon is negatively correlated with the total pesticide residues in soils, and it varied from 181.2 to 350.6 mg kg(-1). Pesticide residues have adversely affected the soil microbial populations, more significantly the bacterial population. The Azotobacter population has decreased to the extent of 51.8 % while actinomycetes were the least affected though accounted for 32 % when compared to the soils with no residue.

  8. Evaluation methodology for comparing memory and communication of analytic processes in visual analytics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ragan, Eric D; Goodall, John R

    2014-01-01

    Provenance tools can help capture and represent the history of analytic processes. In addition to supporting analytic performance, provenance tools can be used to support memory of the process and communication of the steps to others. Objective evaluation methods are needed to evaluate how well provenance tools support analyst s memory and communication of analytic processes. In this paper, we present several methods for the evaluation of process memory, and we discuss the advantages and limitations of each. We discuss methods for determining a baseline process for comparison, and we describe various methods that can be used to elicit processmore » recall, step ordering, and time estimations. Additionally, we discuss methods for conducting quantitative and qualitative analyses of process memory. By organizing possible memory evaluation methods and providing a meta-analysis of the potential benefits and drawbacks of different approaches, this paper can inform study design and encourage objective evaluation of process memory and communication.« less

  9. Method of identity analyte-binding peptides

    DOEpatents

    Kauvar, L.M.

    1990-10-16

    A method for affinity chromatography or adsorption of a designated analyte utilizes a paralog as the affinity partner. The immobilized paralog can be used in purification or analysis of the analyte; the paralog can also be used as a substitute for antibody in an immunoassay. The paralog is identified by screening candidate peptide sequences of 4--20 amino acids for specific affinity to the analyte. 5 figs.

  10. Progress and development of analytical methods for gibberellins.

    PubMed

    Pan, Chaozhi; Tan, Swee Ngin; Yong, Jean Wan Hong; Ge, Liya

    2017-01-01

    Gibberellins, as a group of phytohormones, exhibit a wide variety of bio-functions within plant growth and development, which have been used to increase crop yields. Many analytical procedures, therefore, have been developed for the determination of the types and levels of endogenous and exogenous gibberellins. As plant tissues contain gibberellins in trace amounts (usually at the level of nanogram per gram fresh weight or even lower), the sample pre-treatment steps (extraction, pre-concentration, and purification) for gibberellins are reviewed in details. The primary focus of this comprehensive review is on the various analytical methods designed to meet the requirements for gibberellins analyses in complex matrices with particular emphasis on high-throughput analytical methods, such as gas chromatography, liquid chromatography, and capillary electrophoresis, mostly combined with mass spectrometry. The advantages and drawbacks of the each described analytical method are discussed. The overall aim of this review is to provide a comprehensive and critical view on the different analytical methods nowadays employed to analyze gibberellins in complex sample matrices and their foreseeable trends. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Luminescent detection of hydrazine and hydrazine derivatives

    DOEpatents

    Swager, Timothy M [Newton, MA; Thomas, III, Samuel W.

    2012-04-17

    The present invention generally relates to methods for modulating the optical properties of a luminescent polymer via interaction with a species (e.g., an analyte). In some cases, the present invention provides methods for determination of an analyte by monitoring a change in an optical signal of a luminescent polymer upon exposure to an analyte. Methods of the present invention may be useful for the vapor phase detection of analytes such as explosives and toxins. The present invention also provides methods for increasing the luminescence intensity of a polymer, such as a polymer that has been photobleached, by exposing the luminescent polymer to a species such as a reducing agent.

  12. Method of multi-dimensional moment analysis for the characterization of signal peaks

    DOEpatents

    Pfeifer, Kent B; Yelton, William G; Kerr, Dayle R; Bouchier, Francis A

    2012-10-23

    A method of multi-dimensional moment analysis for the characterization of signal peaks can be used to optimize the operation of an analytical system. With a two-dimensional Peclet analysis, the quality and signal fidelity of peaks in a two-dimensional experimental space can be analyzed and scored. This method is particularly useful in determining optimum operational parameters for an analytical system which requires the automated analysis of large numbers of analyte data peaks. For example, the method can be used to optimize analytical systems including an ion mobility spectrometer that uses a temperature stepped desorption technique for the detection of explosive mixtures.

  13. Downstream processing and chromatography based analytical methods for production of vaccines, gene therapy vectors, and bacteriophages.

    PubMed

    Kramberger, Petra; Urbas, Lidija; Štrancar, Aleš

    2015-01-01

    Downstream processing of nanoplexes (viruses, virus-like particles, bacteriophages) is characterized by complexity of the starting material, number of purification methods to choose from, regulations that are setting the frame for the final product and analytical methods for upstream and downstream monitoring. This review gives an overview on the nanoplex downstream challenges and chromatography based analytical methods for efficient monitoring of the nanoplex production.

  14. Downstream processing and chromatography based analytical methods for production of vaccines, gene therapy vectors, and bacteriophages

    PubMed Central

    Kramberger, Petra; Urbas, Lidija; Štrancar, Aleš

    2015-01-01

    Downstream processing of nanoplexes (viruses, virus-like particles, bacteriophages) is characterized by complexity of the starting material, number of purification methods to choose from, regulations that are setting the frame for the final product and analytical methods for upstream and downstream monitoring. This review gives an overview on the nanoplex downstream challenges and chromatography based analytical methods for efficient monitoring of the nanoplex production. PMID:25751122

  15. Water quality in coastal wetlands: illicit drugs in surface waters of L'Albufera Natural Park (Valencia, Spain)

    NASA Astrophysics Data System (ADS)

    Vazquez-Roig, P.; Blasco, C.; Andreu, V.; Pascual, J. A.; Rubio, J. L.; Picó, Y.

    2010-05-01

    A wide range of emerging pollutants have been identified in environment: antibiotics, hormones, personal care products, etc. But quite recently a new class of ecological threat has been reported: the presence in waters of abuse drugs coming from human consumption [1,2]. Treatment of wastewaters may remove a portion of these compounds, but sometimes, these treatments are insufficient or nonexistent, residues can reach into the aquatic environment. ĹAlbufera Natural Park (Valencia, Spain) is a marsh area of a great interest because it is the habitat of a large quantity of unique species of flora and fauna, and a zone of refuge, feeding and breeding for a large number of migratory birds. However, this area is threatened by urban, industrial and agricultural pressures. The aim of this work has been to develop a fast and sensitive multi-residue analytical method for to establish the occurrence and distribution of commonly consumed illicit drugs in surface waters of ĹAlbufera lake. A representative set of abuse drugs with different mode of action was chosen for this purpose, including: amphetaminics, opiates, cocainics and cannabinoids (THC and nor-9-carboxy-THC). In April 2008 and October 2008 a total of 16 samples of water were collected, corresponding to different sampling points previously designed, and covering the most important channels that flow in to the lake. Samples of 250 mL of water were concentrated by Solid Phase Extraction through an Oasis HLB cartridge and extracted subsequently with methanol as solvent. Quantification was carried out by LC-MS/MS with an ESI interface. Performance characteristics of the PLE-SPE followed by LC-MS/MS were established by validation procedure. Selectivity, linearity, precision, recoveries and limits of detection (LOD) and quantification (LOQ) were studied. Our search shows that current sewage treatment systems do not completely remove illicit drug residues from urban wastewater. Benzoylecgonine, the main metabolite from cocaine, was found in 100% of the samples tested, at concentrations ranging from 0.14 to 78.71 ng/L. Other substances found were nor-9-carboxy-THC, methadone, codeine, cocaine, morphine, ecgonine methyl ester, extasis (MDMA) and amphetamine, while MDA, methamphetamine, heroin, 6-acetylmorphine and THC were undetectable. References: [1] M. Huerta-Fontela,M. T. Galceran, F. Ventura, Anal. Chem. 79 (2007), 3821-3829. [2] E. Zuccato, S. Castiglioni, R. Bagnati, C. Chiabrando, P. Grassi, R. Fanelli, Water Research 42 (2008) 961-968.

  16. The analytical calibration in (bio)imaging/mapping of the metallic elements in biological samples--definitions, nomenclature and strategies: state of the art.

    PubMed

    Jurowski, Kamil; Buszewski, Bogusław; Piekoszewski, Wojciech

    2015-01-01

    Nowadays, studies related to the distribution of metallic elements in biological samples are one of the most important issues. There are many articles dedicated to specific analytical atomic spectrometry techniques used for mapping/(bio)imaging the metallic elements in various kinds of biological samples. However, in such literature, there is a lack of articles dedicated to reviewing calibration strategies, and their problems, nomenclature, definitions, ways and methods used to obtain quantitative distribution maps. The aim of this article was to characterize the analytical calibration in the (bio)imaging/mapping of the metallic elements in biological samples including (1) nomenclature; (2) definitions, and (3) selected and sophisticated, examples of calibration strategies with analytical calibration procedures applied in the different analytical methods currently used to study an element's distribution in biological samples/materials such as LA ICP-MS, SIMS, EDS, XRF and others. The main emphasis was placed on the procedures and methodology of the analytical calibration strategy. Additionally, the aim of this work is to systematize the nomenclature for the calibration terms: analytical calibration, analytical calibration method, analytical calibration procedure and analytical calibration strategy. The authors also want to popularize the division of calibration methods that are different than those hitherto used. This article is the first work in literature that refers to and emphasizes many different and complex aspects of analytical calibration problems in studies related to (bio)imaging/mapping metallic elements in different kinds of biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Application of capability indices and control charts in the analytical method control strategy.

    PubMed

    Oliva, Alexis; Llabres Martinez, Matías

    2017-08-01

    In this study, we assessed the usefulness of control charts in combination with the process capability indices, C pm and C pk , in the control strategy of an analytical method. The traditional X-chart and moving range chart were used to monitor the analytical method over a 2-year period. The results confirmed that the analytical method is in-control and stable. Different criteria were used to establish the specifications limits (i.e. analyst requirements) for fixed method performance (i.e. method requirements). If the specification limits and control limits are equal in breadth, the method can be considered "capable" (C pm  = 1), but it does not satisfy the minimum method capability requirements proposed by Pearn and Shu (2003). Similar results were obtained using the C pk index. The method capability was also assessed as a function of method performance for fixed analyst requirements. The results indicate that the method does not meet the requirements of the analytical target approach. A real-example data of a SEC with light-scattering detection method was used as a model whereas previously published data were used to illustrate the applicability of the proposed approach. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Directivity analysis of meander-line-coil EMATs with a wholly analytical method.

    PubMed

    Xie, Yuedong; Liu, Zenghua; Yin, Liyuan; Wu, Jiande; Deng, Peng; Yin, Wuliang

    2017-01-01

    This paper presents the simulation and experimental study of the radiation pattern of a meander-line-coil EMAT. A wholly analytical method, which involves the coupling of two models: an analytical EM model and an analytical UT model, has been developed to build EMAT models and analyse the Rayleigh waves' beam directivity. For a specific sensor configuration, Lorentz forces are calculated using the EM analytical method, which is adapted from the classic Deeds and Dodd solution. The calculated Lorentz force density are imported to an analytical ultrasonic model as driven point sources, which produce the Rayleigh waves within a layered medium. The effect of the length of the meander-line-coil on the Rayleigh waves' beam directivity is analysed quantitatively and verified experimentally. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Development of an Analytical Method for Dibutyl Phthalate Determination Using Surrogate Analyte Approach

    PubMed Central

    Farzanehfar, Vahid; Faizi, Mehrdad; Naderi, Nima; Kobarfard, Farzad

    2017-01-01

    Dibutyl phthalate (DBP) is a phthalic acid ester and is widely used in polymeric products to make them more flexible. DBP is found in almost every plastic material and is believed to be persistent in the environment. Various analytical methods have been used to measure DBP in different matrices. Considering the ubiquitous nature of DBP, the most important challenge in DBP analyses is the contamination of even analytical grade organic solvents with this compound and lack of availability of a true blank matrix to construct the calibration line. Standard addition method or using artificial matrices reduce the precision and accuracy of the results. In this study a surrogate analyte approach that is based on using deuterium labeled analyte (DBP-d4) to construct the calibration line was applied to determine DBP in hexane samples. PMID:28496469

  20. AmO 2 Analysis for Analytical Method Testing and Assessment: Analysis Support for AmO 2 Production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhn, Kevin John; Bland, Galey Jean; Fulwyler, James Brent

    Americium oxide samples will be measured for various analytes to support AmO 2 production. The key analytes that are currently requested by the Am production customer at LANL include total Am content, Am isotopics, Pu assay, Pu isotopics, and trace element content including 237Np content. Multiple analytical methods will be utilized depending on the sensitivity, accuracy and precision needs of the Am matrix. Traceability to the National Institute of Standards and Technology (NIST) will be achieved, where applicable, by running NIST traceable quality control materials. This given that there are no suitable AmO 2 reference materials currently available for requestedmore » analytes. The primary objective is to demonstrate the suitability of actinide analytical chemistry methods to support AmO 2 production operations.« less

  1. Analytical methods for gelatin differentiation from bovine and porcine origins and food products.

    PubMed

    Nhari, Raja Mohd Hafidz Raja; Ismail, Amin; Che Man, Yaakob B

    2012-01-01

    Usage of gelatin in food products has been widely debated for several years, which is about the source of gelatin that has been used, religion, and health. As an impact, various analytical methods have been introduced and developed to differentiate gelatin whether it is made from porcine or bovine sources. The analytical methods comprise a diverse range of equipment and techniques including spectroscopy, chemical precipitation, chromatography, and immunochemical. Each technique can differentiate gelatins for certain extent with advantages and limitations. This review is focused on overview of the analytical methods available for differentiation of bovine and porcine gelatin and gelatin in food products so that new method development can be established. © 2011 Institute of Food Technologists®

  2. [An experimental proficiency test for ability to screen 104 residual pesticides in agricultural products].

    PubMed

    Tsumura, Yukari; Ishimitsu, Susumu; Otaki, Kayo; Uchimi, Hiroyuki; Matsumoto, Nobuyuki; Daba, Masaki; Tsuchiya, Tetsu; Ukyo, Masaho; Tonogai, Yasuhide

    2003-10-01

    An experimental proficiency test program for ability to screen 104 residual pesticides in agricultural products has been conducted. Eight Japanese laboratories joined the program. Items tested in the present study were limit of detection, internal proficiency test (self spike) and external proficiency test (blind spike). All 104 pesticides were well detected and recovered from agricultural foods in the internal proficiency test. However, the results of the external proficiency test did not completely agree with those of the internal proficiency tests. After 5 rounds of the blind spike test, the ratio of the number of correctly detected pesticides to that of actually contained ones (49 total) ranged from 65% to 100% among laboratories. The numbers of mistakenly detected pesticides by a laboratory were 0 to 15. Thus, there was a great difference among the laboratories in the ability to screen multiresidual pesticides.

  3. The Importance of Method Selection in Determining Product Integrity for Nutrition Research1234

    PubMed Central

    Mudge, Elizabeth M; Brown, Paula N

    2016-01-01

    The American Herbal Products Association estimates that there as many as 3000 plant species in commerce. The FDA estimates that there are about 85,000 dietary supplement products in the marketplace. The pace of product innovation far exceeds that of analytical methods development and validation, with new ingredients, matrixes, and combinations resulting in an analytical community that has been unable to keep up. This has led to a lack of validated analytical methods for dietary supplements and to inappropriate method selection where methods do exist. Only after rigorous validation procedures to ensure that methods are fit for purpose should they be used in a routine setting to verify product authenticity and quality. By following systematic procedures and establishing performance requirements for analytical methods before method development and validation, methods can be developed that are both valid and fit for purpose. This review summarizes advances in method selection, development, and validation regarding herbal supplement analysis and provides several documented examples of inappropriate method selection and application. PMID:26980823

  4. The Importance of Method Selection in Determining Product Integrity for Nutrition Research.

    PubMed

    Mudge, Elizabeth M; Betz, Joseph M; Brown, Paula N

    2016-03-01

    The American Herbal Products Association estimates that there as many as 3000 plant species in commerce. The FDA estimates that there are about 85,000 dietary supplement products in the marketplace. The pace of product innovation far exceeds that of analytical methods development and validation, with new ingredients, matrixes, and combinations resulting in an analytical community that has been unable to keep up. This has led to a lack of validated analytical methods for dietary supplements and to inappropriate method selection where methods do exist. Only after rigorous validation procedures to ensure that methods are fit for purpose should they be used in a routine setting to verify product authenticity and quality. By following systematic procedures and establishing performance requirements for analytical methods before method development and validation, methods can be developed that are both valid and fit for purpose. This review summarizes advances in method selection, development, and validation regarding herbal supplement analysis and provides several documented examples of inappropriate method selection and application. © 2016 American Society for Nutrition.

  5. The current preference for the immuno-analytical ELISA method for quantitation of steroid hormones (endocrine disruptor compounds) in wastewater in South Africa.

    PubMed

    Manickum, Thavrin; John, Wilson

    2015-07-01

    The availability of national test centers to offer a routine service for analysis and quantitation of some selected steroid hormones [natural estrogens (17-β-estradiol, E2; estrone, E1; estriol, E3), synthetic estrogen (17-α-ethinylestradiol, EE2), androgen (testosterone), and progestogen (progesterone)] in wastewater matrix was investigated; corresponding internationally used chemical- and immuno-analytical test methods were reviewed. The enzyme-linked immunosorbent assay (ELISA) (immuno-analytical technique) was also assessed for its suitability as a routine test method to quantitate the levels of these hormones at a sewage/wastewater treatment plant (WTP) (Darvill, Pietermaritzburg, South Africa), over a 2-year period. The method performance and other relevant characteristics of the immuno-analytical ELISA method were compared to the conventional chemical-analytical methodology, like gas/liquid chromatography-mass spectrometry (GC/LC-MS), and GC-LC/tandem mass spectrometry (MSMS), for quantitation of the steroid hormones in wastewater and environmental waters. The national immuno-analytical ELISA technique was found to be sensitive (LOQ 5 ng/L, LOD 0.2-5 ng/L), accurate (mean recovery 96%), precise (RSD 7-10%), and cost-effective for screening and quantitation of these steroid hormones in wastewater and environmental water matrix. A survey of the most current international literature indicates a fairly equal use of the LC-MS/MS, GC-MS/MS (chemical-analytical), and ELISA (immuno-analytical) test methods for screening and quantitation of the target steroid hormones in both water and wastewater matrix. Internationally, the observed sensitivity, based on LOQ (ng/L), for the steroid estrogens E1, E2, EE2, is, in decreasing order: LC-MSMS (0.08-9.54) > GC-MS (1) > ELISA (5) (chemical-analytical > immuno-analytical). At the national level, the routine, unoptimized chemical-analytical LC-MSMS method was found to lack the required sensitivity for meeting environmental requirements for steroid hormone quantitation. Further optimization of the sensitivity of the chemical-analytical LC-tandem mass spectrometry methods, especially for wastewater screening, in South Africa is required. Risk assessment studies showed that it was not practical to propose standards or allowable limits for the steroid estrogens E1, E2, EE2, and E3; the use of predicted-no-effect concentration values of the steroid estrogens appears to be appropriate for use in their risk assessment in relation to aquatic organisms. For raw water sources, drinking water, raw and treated wastewater, the use of bioassays, with trigger values, is a useful screening tool option to decide whether further examination of specific endocrine activity may be warranted, or whether concentrations of such activity are of low priority, with respect to health concerns in the human population. The achievement of improved quantitation limits for immuno-analytical methods, like ELISA, used for compound quantitation, and standardization of the method for measuring E2 equivalents (EEQs) used for biological activity (endocrine: e.g., estrogenic) are some areas for future EDC research.

  6. Quantifying Acoustic Impacts on Marine Mammals and Sea Turtles: Methods and Analytical Approach for Phase III Training and Testing

    DTIC Science & Technology

    2017-06-16

    Acoustic Impacts on Marine Mammals and Sea Turtles: Methods and Analytical Approach for Phase III Training and Testing Sarah A. Blackstock Joseph O...December 2017 4. TITLE AND SUBTITLE Quantifying Acoustic Impacts on Marine Mammals and Sea Turtles: Methods and Analytical Approach for Phase III...Navy’s Phase III Study Areas as described in each Environmental Impact Statement/ Overseas Environmental Impact Statement and describes the methods

  7. Differential homogeneous immunosensor device

    DOEpatents

    Malmros, Mark K.; Gulbinski, III, Julian

    1990-04-10

    There is provided a novel method of testing for the presence of an analyte in a fluid suspected of containing the same. In this method, in the presence of the analyte, a substance capable of modifying certain characteristics of the substrate is bound to the substrate and the change in these qualities is measured. While the method may be modified for carrying out quantitative differential analyses, it eliminates the need for washing analyte from the substrate which is characteristic of prior art methods.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, D.W.; Heinrich, R.R.; Graczyk, D.G.

    The purpose of this report is to summarize the activities of the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) for fiscal year 1988 (October 1987 through September 1988). The Analytical Chemistry Laboratory is a full-cost recovery service center, with the primary mission of providing a broad range of analytical chemistry support services to the scientific and engineering programs at ANL. In addition, the ACL conducts a research program in analytical chemistry, works on instrumental and methods development, and provides analytical services for governmental, educational, and industrial organizations. The ACL handles a wide range of analytical problems, from routinemore » standard analyses to unique problems that require significant development of methods and techniques.« less

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, D.W.; Heinrich, R.R.; Graczyk, D.G.

    The purpose of this report is to summarize the activities of the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) for Fiscal Year 1989 (October 1988 through September 1989). The Analytical Chemistry Laboratory is a full-cost-recovery service center, with the primary mission of providing a broad range of analytical chemistry support services to the scientific and engineering programs at ANL. In addition, the ACL conducts a research program in analytical chemistry, works on instrumental and methods development, and provides analytical services for governmental, educational, and industrial organizations. The ACL handles a wide range of analytical problems, from routine standardmore » analyses to unique problems that require significant development of methods and techniques.« less

  10. Visual analytics for aviation safety: A collaborative approach to sensemaking

    NASA Astrophysics Data System (ADS)

    Wade, Andrew

    Visual analytics, the "science of analytical reasoning facilitated by interactive visual interfaces", is more than just visualization. Understanding the human reasoning process is essential for designing effective visualization tools and providing correct analyses. This thesis describes the evolution, application and evaluation of a new method for studying analytical reasoning that we have labeled paired analysis. Paired analysis combines subject matter experts (SMEs) and tool experts (TE) in an analytic dyad, here used to investigate aircraft maintenance and safety data. The method was developed and evaluated using interviews, pilot studies and analytic sessions during an internship at the Boeing Company. By enabling a collaborative approach to sensemaking that can be captured by researchers, paired analysis yielded rich data on human analytical reasoning that can be used to support analytic tool development and analyst training. Keywords: visual analytics, paired analysis, sensemaking, boeing, collaborative analysis.

  11. Pesticide Analytical Methods

    EPA Pesticide Factsheets

    Pesticide manufacturers must develop and submit analytical methods for their pesticide products to support registration of their products under FIFRA. Learn about these methods as well as SOPs for testing of antimicrobial products against three organisms.

  12. [Determination of six anticoccidials in chicken using QuEChERS combined with ultra high liquid chromatography-high resolution mass spectrometry].

    PubMed

    Muharem, Muhteber; Yan, Hua; Xu, Shan; Feng, Nan; Hao, Jie; Zhu, Chenqi; Guo, Shuang; Zhang, Zhaohui; Han, Nanyin

    2015-11-01

    An ultra high liquid chromatography-Q Exactive orbitrap mass spectrometry multi-residue method has been developed for the determination of six anticoccidials residues (dinitlmide, nicarbazin, diclazuril, toltrazuril, monensin and salinomycin) in chicken tissue. Sample preparation was based on QuEChERS method, using 1% (v/v) trichloroacetic acid/acetonitrile aqueous solution (3:7, v/v) as the extraction solvent and salting-out with sodium chloride followed by clean-up with 50 mg/mL primary secondary amine (PSA) +50 mg/mL neutral alumina (Alumina-N) dispersive solid phase extraction (DSPE). The separation of the compounds in liquid chromatography was carried out using a Waters Acquity UPLC BEH C8 column (100 mm x 2.1 mm, 1.7 μm) with mobile phases consisting of methanol-5 mmol/L ammonium acetate aqueous solution in gradient elution. The Q Exactive orbitrap mass spectrometric detection was carried out with positive and negative electrospray ionization simultaneously. The results showed the linear ranges of the six target compounds were as follows: dinitolmide, 1.0-30.0 μg/L; nicarbazin, 0.2-6.0 μg/L; diclazuril and toltrazuril, 2.0-60.0 [μg/L; monensin and salinomycin, 4.0-120.0 μg/L. The external standard method was used for quantification. The spiked recoveries at three levels for the six anticoccidials ranged from 67.7% to 126.8%. The relative standard deviations (RSDs) were ≤ 10.4%. The limits of quantification (LOQs) were as follows: dinitolmide, 2.50 μg/kg; nicarbazin, 0.50 μg/kg; diclazuril and toltrazuril, 5.00 μg/kg; monensin and salinomycin, 20.00 μg/kg. The developed method is easy of operation and of high sensitivity. It can meet the requirements of daily inspection.

  13. Development of a method for the analysis of hormones and pharmaceuticals in earthworms by quick, easy, cheap, effective, rugged and safe (QuEChERS) extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS).

    PubMed

    Bergé, Alexandre; Vulliet, Emmanuelle

    2015-10-01

    The earthworm represents a kind of creature in contact with the soil surface and usually exposed to a variety of organic pollutants from human activities. Therefore, it can be considered as an organism of choice for identifying pollution or better understanding the input of contaminants in food chains in particular through the contributions of sludge. Moreover, the use of organisms such as soil invertebrates is to be developed for ecotoxicological risk assessment of pollutants. In this context, a simple, rapid and effective multi-residue method was developed for the determination of 31 compounds including 11 steroids, 14 veterinary antibiotics and 6 human contaminants (paracetamol, sulfamethoxazole, fluvoxamine, carbamazepine, ibuprofen, bisphenol A) in earthworm. The sample preparation procedure was based on a salting-out extraction with acetonitrile (QuEChERS approach) that was optimised with regard to the acetonitrile/water ratio used in the extraction step, the choice of the clean-up and the quantity of the matrix. The optimised extraction method exhibited recoveries that comprised between 44 and 98 % for all the tested compounds. The limits of detection of all compounds were below 14 ng g(-1) and the limits of quantification (LOQ) comprised between 1.6 and 40 ng g(-1) (wet weight). The method was therefore applied to determine the levels of pharmaceuticals and hormones in six earthworm samples collected in various soils. Concentrations up to 195 ng g(-1) for bisphenol A were determined, between a few nanograms per gram and 43.1 ng g(-1) (estriol) for hormones and between a few nanograms per gram and 73.5 ng g(-1) (florfenicol) for pharmaceuticals. Experiments were also conducted in laboratory conditions to evaluate the accumulation of the target substances by earthworm.

  14. Semi-analytic valuation of stock loans with finite maturity

    NASA Astrophysics Data System (ADS)

    Lu, Xiaoping; Putri, Endah R. M.

    2015-10-01

    In this paper we study stock loans of finite maturity with different dividend distributions semi-analytically using the analytical approximation method in Zhu (2006). Stock loan partial differential equations (PDEs) are established under Black-Scholes framework. Laplace transform method is used to solve the PDEs. Optimal exit price and stock loan value are obtained in Laplace space. Values in the original time space are recovered by numerical Laplace inversion. To demonstrate the efficiency and accuracy of our semi-analytic method several examples are presented, the results are compared with those calculated using existing methods. We also present a calculation of fair service fee charged by the lender for different loan parameters.

  15. Methods of use for sensor based fluid detection devices

    NASA Technical Reports Server (NTRS)

    Lewis, Nathan S. (Inventor)

    2001-01-01

    Methods of use and devices for detecting analyte in fluid. A system for detecting an analyte in a fluid is described comprising a substrate having a sensor comprising a first organic material and a second organic material where the sensor has a response to permeation by an analyte. A detector is operatively associated with the sensor. Further, a fluid delivery appliance is operatively associated with the sensor. The sensor device has information storage and processing equipment, which is operably connected with the device. This device compares a response from the detector with a stored ideal response to detect the presence of analyte. An integrated system for detecting an analyte in a fluid is also described where the sensing device, detector, information storage and processing device, and fluid delivery device are incorporated in a substrate. Methods for use for the above system are also described where the first organic material and a second organic material are sensed and the analyte is detected with a detector operatively associated with the sensor. The method provides for a device, which delivers fluid to the sensor and measures the response of the sensor with the detector. Further, the response is compared to a stored ideal response for the analyte to determine the presence of the analyte. In different embodiments, the fluid measured may be a gaseous fluid, a liquid, or a fluid extracted from a solid. Methods of fluid delivery for each embodiment are accordingly provided.

  16. \\tLaboratory Environmental Sample Disposal Information Document - Companion to Standardized Analytical Methods for Environmental Restoration Following Homeland Security Events (SAM) – Revision 5.0

    EPA Pesticide Factsheets

    Document is intended to provide general guidelines for use byEPA and EPA-contracted laboratories when disposing of samples and associated analytical waste following use of the analytical methods listed in SAM.

  17. The NIH analytical methods and reference materials program for dietary supplements.

    PubMed

    Betz, Joseph M; Fisher, Kenneth D; Saldanha, Leila G; Coates, Paul M

    2007-09-01

    Quality of botanical products is a great uncertainty that consumers, clinicians, regulators, and researchers face. Definitions of quality abound, and include specifications for sanitation, adventitious agents (pesticides, metals, weeds), and content of natural chemicals. Because dietary supplements (DS) are often complex mixtures, they pose analytical challenges and method validation may be difficult. In response to product quality concerns and the need for validated and publicly available methods for DS analysis, the US Congress directed the Office of Dietary Supplements (ODS) at the National Institutes of Health (NIH) to accelerate an ongoing methods validation process, and the Dietary Supplements Methods and Reference Materials Program was created. The program was constructed from stakeholder input and incorporates several federal procurement and granting mechanisms in a coordinated and interlocking framework. The framework facilitates validation of analytical methods, analytical standards, and reference materials.

  18. A multiple hollow fibre liquid-phase microextraction method for the determination of halogenated solvent residues in olive oil.

    PubMed

    Manso, J; García-Barrera, T; Gómez-Ariza, J L; González, A G

    2014-02-01

    The present paper describes a method based on the extraction of analytes by multiple hollow fibre liquid-phase microextraction and detection by ion-trap mass spectrometry and electron capture detectors after gas chromatographic separation. The limits of detection are in the range of 0.13-0.67 μg kg(-1), five orders of magnitude lower than those reached with the European Commission Official method of analysis, with three orders of magnitude of linear range (from the quantification limits to 400 μg kg(-1) for all the analytes) and recoveries in fortified olive oils in the range of 78-104 %. The main advantages of the analytical method are the absence of sample carryover (due to the disposable nature of the membranes), high enrichment factors in the range of 79-488, high throughput and low cost. The repeatability of the analytical method ranged from 8 to 15 % for all the analytes, showing a good performance.

  19. Rapid detection and identification of energetic materials with surface enhanced raman spectrometry (SERS)

    DOEpatents

    Han, Thomas Yong-Jin; Valdez, Carlos A; Olson, Tammy Y; Kim, Sung Ho; Satcher, Jr., Joe H

    2015-04-21

    In one embodiment, a system includes a plurality of metal nanoparticles functionalized with a plurality of organic molecules tethered thereto, wherein the plurality of organic molecules preferentially interact with one or more analytes when placed in proximity therewith. According to another embodiment, a method for detecting analytes includes contacting a fluid having one or more analytes of interest therein with a plurality of metal nanoparticles, each metal nanoparticle having a plurality of organic molecules tethered thereto, and detecting Raman scattering from an analyte of interest from the fluid, the analyte interacting with one or more of the plurality of organic molecules. In another embodiment, a method includes chemically modifying a plurality of cyclodextrin molecules at a primary hydroxyl moiety to create a chemical handle, and tethering the plurality of cyclodextrin molecules to a metal nanoparticle using the chemical handle. Other systems and methods for detecting analytes are also described.

  20. SAM Companion Documents

    EPA Pesticide Factsheets

    SAM Companion Documents and Sample Collection Procedures provide information intended to complement the analytical methods listed in Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  1. Differential homogeneous immunosensor device

    DOEpatents

    Malmros, M.K.; Gulbinski, J. III.

    1990-04-10

    There is provided a novel method of testing for the presence of an analyte in a fluid suspected of containing the same. In this method, in the presence of the analyte, a substance capable of modifying certain characteristics of the substrate is bound to the substrate and the change in these qualities is measured. While the method may be modified for carrying out quantitative differential analyses, it eliminates the need for washing the analyte from the substrate which is characteristic of prior art methods. 12 figs.

  2. Applying an analytical method to study neutron behavior for dosimetry

    NASA Astrophysics Data System (ADS)

    Shirazi, S. A. Mousavi

    2016-12-01

    In this investigation, a new dosimetry process is studied by applying an analytical method. This novel process is associated with a human liver tissue. The human liver tissue has compositions including water, glycogen and etc. In this study, organic compound materials of liver are decomposed into their constituent elements based upon mass percentage and density of every element. The absorbed doses are computed by analytical method in all constituent elements of liver tissue. This analytical method is introduced applying mathematical equations based on neutron behavior and neutron collision rules. The results show that the absorbed doses are converged for neutron energy below 15MeV. This method can be applied to study the interaction of neutrons in other tissues and estimating the absorbed dose for a wide range of neutron energy.

  3. A technique for setting analytical thresholds in massively parallel sequencing-based forensic DNA analysis

    PubMed Central

    2017-01-01

    Amplicon (targeted) sequencing by massively parallel sequencing (PCR-MPS) is a potential method for use in forensic DNA analyses. In this application, PCR-MPS may supplement or replace other instrumental analysis methods such as capillary electrophoresis and Sanger sequencing for STR and mitochondrial DNA typing, respectively. PCR-MPS also may enable the expansion of forensic DNA analysis methods to include new marker systems such as single nucleotide polymorphisms (SNPs) and insertion/deletions (indels) that currently are assayable using various instrumental analysis methods including microarray and quantitative PCR. Acceptance of PCR-MPS as a forensic method will depend in part upon developing protocols and criteria that define the limitations of a method, including a defensible analytical threshold or method detection limit. This paper describes an approach to establish objective analytical thresholds suitable for multiplexed PCR-MPS methods. A definition is proposed for PCR-MPS method background noise, and an analytical threshold based on background noise is described. PMID:28542338

  4. A technique for setting analytical thresholds in massively parallel sequencing-based forensic DNA analysis.

    PubMed

    Young, Brian; King, Jonathan L; Budowle, Bruce; Armogida, Luigi

    2017-01-01

    Amplicon (targeted) sequencing by massively parallel sequencing (PCR-MPS) is a potential method for use in forensic DNA analyses. In this application, PCR-MPS may supplement or replace other instrumental analysis methods such as capillary electrophoresis and Sanger sequencing for STR and mitochondrial DNA typing, respectively. PCR-MPS also may enable the expansion of forensic DNA analysis methods to include new marker systems such as single nucleotide polymorphisms (SNPs) and insertion/deletions (indels) that currently are assayable using various instrumental analysis methods including microarray and quantitative PCR. Acceptance of PCR-MPS as a forensic method will depend in part upon developing protocols and criteria that define the limitations of a method, including a defensible analytical threshold or method detection limit. This paper describes an approach to establish objective analytical thresholds suitable for multiplexed PCR-MPS methods. A definition is proposed for PCR-MPS method background noise, and an analytical threshold based on background noise is described.

  5. Analytic Methods in Investigative Geometry.

    ERIC Educational Resources Information Center

    Dobbs, David E.

    2001-01-01

    Suggests an alternative proof by analytic methods, which is more accessible than rigorous proof based on Euclid's Elements, in which students need only apply standard methods of trigonometry to the data without introducing new points or lines. (KHR)

  6. Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory - Determination of Moderate-Use Pesticides and Selected Degradates in Water by C-18 Solid-Phase Extraction and Gas Chromatography/Mass Spectrometry

    USGS Publications Warehouse

    Sandstrom, Mark W.; Stroppel, Max E.; Foreman, William T.; Schroeder, Michael P.

    2001-01-01

    A method for the isolation and analysis of 21 parent pesticides and 20 pesticide degradates in natural-water samples is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase-extraction columns that contain octadecyl-bonded porous silica to extract the analytes. The columns are dried by using nitrogen gas, and adsorbed analytes are eluted with ethyl acetate. Extracted analytes are determined by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring of three characteristic ions. The upper concentration limit is 2 micrograms per liter (?g/L) for most analytes. Single-operator method detection limits in reagent-water samples range from 0.00 1 to 0.057 ?g/L. Validation data also are presented for 14 parent pesticides and 20 degradates that were determined to have greater bias or variability, or shorter holding times than the other compounds. The estimated maximum holding time for analytes in pesticide-grade water before extraction was 4 days. The estimated maximum holding time for analytes after extraction on the dry solid-phase-extraction columns was 7 days. An optional on-site extraction procedure allows for samples to be collected and processed at remote sites where it is difficult to ship samples to the laboratory within the recommended pre-extraction holding time. The method complements existing U.S. Geological Survey Method O-1126-95 (NWQL Schedules 2001 and 2010) by using identical sample preparation and comparable instrument analytical conditions so that sample extracts can be analyzed by either method to expand the range of analytes determined from one water sample.

  7. Method and apparatus for detecting an analyte

    DOEpatents

    Allendorf, Mark D [Pleasanton, CA; Hesketh, Peter J [Atlanta, GA

    2011-11-29

    We describe the use of coordination polymers (CP) as coatings on microcantilevers for the detection of chemical analytes. CP exhibit changes in unit cell parameters upon adsorption of analytes, which will induce a stress in a static microcantilever upon which a CP layer is deposited. We also describe fabrication methods for depositing CP layers on surfaces.

  8. CTEPP STANDARD OPERATING PROCEDURE FOR PREPARATION OF SURROGATE RECOVERY STANDARD AND INTERNAL STANDARD SOLUTIONS FOR POLAR TARGET ANALYTES (SOP-5.26)

    EPA Science Inventory

    This SOP describes the method used for preparing surrogate recovery standard and internal standard solutions for the analysis of polar target analytes. It also describes the method for preparing calibration standard solutions for polar analytes used for gas chromatography/mass sp...

  9. Design and analysis of tubular permanent magnet linear generator for small-scale wave energy converter

    NASA Astrophysics Data System (ADS)

    Kim, Jeong-Man; Koo, Min-Mo; Jeong, Jae-Hoon; Hong, Keyyong; Cho, Il-Hyoung; Choi, Jang-Young

    2017-05-01

    This paper reports the design and analysis of a tubular permanent magnet linear generator (TPMLG) for a small-scale wave-energy converter. The analytical field computation is performed by applying a magnetic vector potential and a 2-D analytical model to determine design parameters. Based on analytical solutions, parametric analysis is performed to meet the design specifications of a wave-energy converter (WEC). Then, 2-D FEA is employed to validate the analytical method. Finally, the experimental result confirms the predictions of the analytical and finite element analysis (FEA) methods under regular and irregular wave conditions.

  10. Thermodynamics of Gas Turbine Cycles with Analytic Derivatives in OpenMDAO

    NASA Technical Reports Server (NTRS)

    Gray, Justin; Chin, Jeffrey; Hearn, Tristan; Hendricks, Eric; Lavelle, Thomas; Martins, Joaquim R. R. A.

    2016-01-01

    A new equilibrium thermodynamics analysis tool was built based on the CEA method using the OpenMDAO framework. The new tool provides forward and adjoint analytic derivatives for use with gradient based optimization algorithms. The new tool was validated against the original CEA code to ensure an accurate analysis and the analytic derivatives were validated against finite-difference approximations. Performance comparisons between analytic and finite difference methods showed a significant speed advantage for the analytic methods. To further test the new analysis tool, a sample optimization was performed to find the optimal air-fuel equivalence ratio, , maximizing combustion temperature for a range of different pressures. Collectively, the results demonstrate the viability of the new tool to serve as the thermodynamic backbone for future work on a full propulsion modeling tool.

  11. The combination of four analytical methods to explore skeletal muscle metabolomics: Better coverage of metabolic pathways or a marketing argument?

    PubMed

    Bruno, C; Patin, F; Bocca, C; Nadal-Desbarats, L; Bonnier, F; Reynier, P; Emond, P; Vourc'h, P; Joseph-Delafont, K; Corcia, P; Andres, C R; Blasco, H

    2018-01-30

    Metabolomics is an emerging science based on diverse high throughput methods that are rapidly evolving to improve metabolic coverage of biological fluids and tissues. Technical progress has led researchers to combine several analytical methods without reporting the impact on metabolic coverage of such a strategy. The objective of our study was to develop and validate several analytical techniques (mass spectrometry coupled to gas or liquid chromatography and nuclear magnetic resonance) for the metabolomic analysis of small muscle samples and evaluate the impact of combining methods for more exhaustive metabolite covering. We evaluated the muscle metabolome from the same pool of mouse muscle samples after 2 metabolite extraction protocols. Four analytical methods were used: targeted flow injection analysis coupled with mass spectrometry (FIA-MS/MS), gas chromatography coupled with mass spectrometry (GC-MS), liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS), and nuclear magnetic resonance (NMR) analysis. We evaluated the global variability of each compound i.e., analytical (from quality controls) and extraction variability (from muscle extracts). We determined the best extraction method and we reported the common and distinct metabolites identified based on the number and identity of the compounds detected with low analytical variability (variation coefficient<30%) for each method. Finally, we assessed the coverage of muscle metabolic pathways obtained. Methanol/chloroform/water and water/methanol were the best extraction solvent for muscle metabolome analysis by NMR and MS, respectively. We identified 38 metabolites by nuclear magnetic resonance, 37 by FIA-MS/MS, 18 by GC-MS, and 80 by LC-HRMS. The combination led us to identify a total of 132 metabolites with low variability partitioned into 58 metabolic pathways, such as amino acid, nitrogen, purine, and pyrimidine metabolism, and the citric acid cycle. This combination also showed that the contribution of GC-MS was low when used in combination with other mass spectrometry methods and nuclear magnetic resonance to explore muscle samples. This study reports the validation of several analytical methods, based on nuclear magnetic resonance and several mass spectrometry methods, to explore the muscle metabolome from a small amount of tissue, comparable to that obtained during a clinical trial. The combination of several techniques may be relevant for the exploration of muscle metabolism, with acceptable analytical variability and overlap between methods However, the difficult and time-consuming data pre-processing, processing, and statistical analysis steps do not justify systematically combining analytical methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Comparative Chemometric Analysis for Classification of Acids and Bases via a Colorimetric Sensor Array.

    PubMed

    Kangas, Michael J; Burks, Raychelle M; Atwater, Jordyn; Lukowicz, Rachel M; Garver, Billy; Holmes, Andrea E

    2018-02-01

    With the increasing availability of digital imaging devices, colorimetric sensor arrays are rapidly becoming a simple, yet effective tool for the identification and quantification of various analytes. Colorimetric arrays utilize colorimetric data from many colorimetric sensors, with the multidimensional nature of the resulting data necessitating the use of chemometric analysis. Herein, an 8 sensor colorimetric array was used to analyze select acid and basic samples (0.5 - 10 M) to determine which chemometric methods are best suited for classification quantification of analytes within clusters. PCA, HCA, and LDA were used to visualize the data set. All three methods showed well-separated clusters for each of the acid or base analytes and moderate separation between analyte concentrations, indicating that the sensor array can be used to identify and quantify samples. Furthermore, PCA could be used to determine which sensors showed the most effective analyte identification. LDA, KNN, and HQI were used for identification of analyte and concentration. HQI and KNN could be used to correctly identify the analytes in all cases, while LDA correctly identified 95 of 96 analytes correctly. Additional studies demonstrated that controlling for solvent and image effects was unnecessary for all chemometric methods utilized in this study.

  13. Method development and validation for simultaneous quantification of 15 drugs of abuse and prescription drugs and 7 of their metabolites in whole blood relevant in the context of driving under the influence of drugs--usefulness of multi-analyte calibration.

    PubMed

    Steuer, Andrea E; Forss, Anna-Maria; Dally, Annika M; Kraemer, Thomas

    2014-11-01

    In the context of driving under the influence of drugs (DUID), not only common drugs of abuse may have an influence, but also medications with similar mechanisms of action. Simultaneous quantification of a variety of drugs and medications relevant in this context allows faster and more effective analyses. Therefore, multi-analyte approaches have gained more and more popularity in recent years. Usually, calibration curves for such procedures contain a mixture of all analytes, which might lead to mutual interferences. In this study we investigated whether the use of such mixtures leads to reliable results for authentic samples containing only one or two analytes. Five hundred microliters of whole blood were extracted by routine solid-phase extraction (SPE, HCX). Analysis was performed on an ABSciex 3200 QTrap instrument with ESI+ in scheduled MRM mode. The method was fully validated according to international guidelines including selectivity, recovery, matrix effects, accuracy and precision, stabilities, and limit of quantification. The selected SPE provided recoveries >60% for all analytes except 6-monoacetylmorphine (MAM) with coefficients of variation (CV) below 15% or 20% for quality controls (QC) LOW and HIGH, respectively. Ion suppression >30% was found for benzoylecgonine, hydrocodone, hydromorphone, MDA, oxycodone, and oxymorphone at QC LOW, however CVs were always below 10% (n=6 different whole blood samples). Accuracy and precision criteria were fulfilled for all analytes except for MAM. Systematic investigation of accuracy determined for QC MED in a multi-analyte mixture compared to samples containing only single analytes revealed no relevant differences for any analyte, indicating that a multi-analyte calibration is suitable for the presented method. Comparison of approximately 60 samples to a former GC-MS method showed good correlation. The newly validated method was successfully applied to more than 1600 routine samples and 3 proficiency tests. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. A new tool for the evaluation of the analytical procedure: Green Analytical Procedure Index.

    PubMed

    Płotka-Wasylka, J

    2018-05-01

    A new means for assessing analytical protocols relating to green analytical chemistry attributes has been developed. The new tool, called GAPI (Green Analytical Procedure Index), evaluates the green character of an entire analytical methodology, from sample collection to final determination, and was created using such tools as the National Environmental Methods Index (NEMI) or Analytical Eco-Scale to provide not only general but also qualitative information. In GAPI, a specific symbol with five pentagrams can be used to evaluate and quantify the environmental impact involved in each step of an analytical methodology, mainly from green through yellow to red depicting low, medium to high impact, respectively. The proposed tool was used to evaluate analytical procedures applied in the determination of biogenic amines in wine samples, and polycyclic aromatic hydrocarbon determination by EPA methods. GAPI tool not only provides an immediately perceptible perspective to the user/reader but also offers exhaustive information on evaluated procedures. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Modern analytical chemistry in the contemporary world

    NASA Astrophysics Data System (ADS)

    Šíma, Jan

    2016-12-01

    Students not familiar with chemistry tend to misinterpret analytical chemistry as some kind of the sorcery where analytical chemists working as modern wizards handle magical black boxes able to provide fascinating results. However, this approach is evidently improper and misleading. Therefore, the position of modern analytical chemistry among sciences and in the contemporary world is discussed. Its interdisciplinary character and the necessity of the collaboration between analytical chemists and other experts in order to effectively solve the actual problems of the human society and the environment are emphasized. The importance of the analytical method validation in order to obtain the accurate and precise results is highlighted. The invalid results are not only useless; they can often be even fatal (e.g., in clinical laboratories). The curriculum of analytical chemistry at schools and universities is discussed. It is referred to be much broader than traditional equilibrium chemistry coupled with a simple description of individual analytical methods. Actually, the schooling of analytical chemistry should closely connect theory and practice.

  16. Method Development in Forensic Toxicology.

    PubMed

    Peters, Frank T; Wissenbach, Dirk K; Busardo, Francesco Paolo; Marchei, Emilia; Pichini, Simona

    2017-01-01

    In the field of forensic toxicology, the quality of analytical methods is of great importance to ensure the reliability of results and to avoid unjustified legal consequences. A key to high quality analytical methods is a thorough method development. The presented article will provide an overview on the process of developing methods for forensic applications. This includes the definition of the method's purpose (e.g. qualitative vs quantitative) and the analytes to be included, choosing an appropriate sample matrix, setting up separation and detection systems as well as establishing a versatile sample preparation. Method development is concluded by an optimization process after which the new method is subject to method validation. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  17. Positive lists of cosmetic ingredients: Analytical methodology for regulatory and safety controls - A review.

    PubMed

    Lores, Marta; Llompart, Maria; Alvarez-Rivera, Gerardo; Guerra, Eugenia; Vila, Marlene; Celeiro, Maria; Lamas, J Pablo; Garcia-Jares, Carmen

    2016-04-07

    Cosmetic products placed on the market and their ingredients, must be safe under reasonable conditions of use, in accordance to the current legislation. Therefore, regulated and allowed chemical substances must meet the regulatory criteria to be used as ingredients in cosmetics and personal care products, and adequate analytical methodology is needed to evaluate the degree of compliance. This article reviews the most recent methods (2005-2015) used for the extraction and the analytical determination of the ingredients included in the positive lists of the European Regulation of Cosmetic Products (EC 1223/2009): comprising colorants, preservatives and UV filters. It summarizes the analytical properties of the most relevant analytical methods along with the possibilities of fulfilment of the current regulatory issues. The cosmetic legislation is frequently being updated; consequently, the analytical methodology must be constantly revised and improved to meet safety requirements. The article highlights the most important advances in analytical methodology for cosmetics control, both in relation to the sample pretreatment and extraction and the different instrumental approaches developed to solve this challenge. Cosmetics are complex samples, and most of them require a sample pretreatment before analysis. In the last times, the research conducted covering this aspect, tended to the use of green extraction and microextraction techniques. Analytical methods were generally based on liquid chromatography with UV detection, and gas and liquid chromatographic techniques hyphenated with single or tandem mass spectrometry; but some interesting proposals based on electrophoresis have also been reported, together with some electroanalytical approaches. Regarding the number of ingredients considered for analytical control, single analyte methods have been proposed, although the most useful ones in the real life cosmetic analysis are the multianalyte approaches. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Analytical capabilities and services of Lawrence Livermore Laboratory's General Chemistry Division. [Methods available at Lawrence Livermore

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gutmacher, R.; Crawford, R.

    This comprehensive guide to the analytical capabilities of Lawrence Livermore Laboratory's General Chemistry Division describes each analytical method in terms of its principle, field of application, and qualitative and quantitative uses. Also described are the state and quantity of sample required for analysis, processing time, available instrumentation, and responsible personnel.

  19. Determination of 22 triazole compounds including parent fungicides and metabolites in apples, peaches, flour, and water by liquid chromatography/tandem mass spectrometry.

    PubMed

    Schermerhorn, Patricia G; Golden, Paul E; Krynitsky, Alexander J; Leimkuehler, William M

    2005-01-01

    A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed for the determination of 14 parent triazole fungicides and 8 of their metabolites found in apples, peaches, flour, raw water, and tap water. The triazole fungicides chosen for this multiresidue method development project included propiconazole, fenbuconazole and its RH-9129 and RH-9130 metabolites, cyproconazole, difenoconazole, tebuconazole and its HWG 2061 metabolite, hexaconazole, bromuconazole (both stereoisomers), epoxiconazole, tetraconazole, triticonazole and its RPA-404886 and RPA-406341 metabolites, triadimefon, triadimenol, and myclobutanil. Of special concern to the U.S. Environmental Protection Agency were the metabolites common to all triazole fungicides: free triazole, 1,2,4-triazole (T), and its 2 conjugates: triazolylalanine (TA) and triazolylacetic acid (TAA). These metabolites were the primary focus of this project. All samples we cleaned up by a combination of C18 solid-phase extraction (SPE), mixed-mode cationic SPE, and mixed-mode anionic SPE columns. A triple-stage quadrupole mass spectrometer, equipped with electrospray ionization in the positive-ion mode, was used to determine the compounds of interest. T, TA, and TAA were quantitated using isotopically labeled internal standards (IS), in which the 1,2,4-triazole ring had been synthesized by using 13C and 15N (IS_T, IS_TA, and IS_TAA). These isotopically labeled internal standards were necessary to correct for matrix effects. The T, TA, and TAA metabolites were quantitated at the 25-50 parts-per-billion (ppb) level in food commodities and at 0.50 ppb in water. Recoveries were 70-101% from apples, 60-121% from peaches, 57-118% from flour, 75-99% from raw water, and 79-99% from tap water.

  20. A workflow for multiclass determination of 256 pesticides in essential oils by liquid chromatography tandem mass spectrometry using evaporation and dilution approaches: Application to lavandin, lemon and cypress essential oils.

    PubMed

    Fillatre, Yoann; Rondeau, David; Daguin, Antoine; Communal, Pierre-Yves

    2016-01-01

    This paper describes the determination of 256 multiclass pesticides in cypress and lemon essential oils (EOs) by the way of liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) analysis using the scheduled selected reaction monitoring mode (sSRM) available on a hybrid quadrupole linear ion trap (QLIT) mass spectrometer. The performance of a sample preparation of lemon and cypress EOs based on dilution or evaporation under nitrogen assisted by a controlled heating were assessed. The best limits of quantification (LOQs) were achieved with the evaporation under nitrogen method giving LOQs≤10µgL(-1) for 91% of the pesticides. In addition the very satisfactory results obtained for recovery, repeatability and linearity showed that for EOs of relatively low evaporation temperature, a sample preparation based on evaporation under nitrogen is well adapted and preferable to dilution. By compiling these results with those previously published by some of us on lavandin EO, we proposed a workflow dedicated to multiresidue determination of pesticides in various EOs by LC-ESI/sSRM. Among the steps involved in this workflow, the protocol related to mass spectrometry proposes an alternative confirmation method to the classical SRM ratio criteria based on a sSRM survey scan followed by an information-dependent acquisition using the sensitive enhanced product ion (EPI) scan to generate MS/MS spectra then compared to a reference. The submitted workflow was applied to the case of lemon EOs samples highlighting for the first time the simultaneous detection of 20 multiclass pesticides in one EO. Some pesticides showed very high concentration levels with amounts greatly exceeding the mgL(-1). Copyright © 2015 Elsevier B.V. All rights reserved.

  1. A sensitive and efficient method for routine pesticide multiresidue analysis in bee pollen samples using gas and liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Vázquez, P Parrilla; Lozano, A; Uclés, S; Ramos, M M Gómez; Fernández-Alba, A R

    2015-12-24

    Several clean-up methods were evaluated for 253 pesticides in pollen samples concentrating on efficient clean-up and the highest number of pesticides satisfying the recovery and precision criteria. These were: (a) modified QuEChERS using dSPE with PSA+C18; (b) freeze-out prior to QuEChERS using dSPE with PSA+C18; (c) freeze-out prior to QuEChERS using dSPE with PSA+C18+Z-Sep; and (d) freeze-out followed by QuEChERS using dSPE with PSA+C18 and SPE with Z-Sep. Determinations were made using LC-MS/MS and GC-MS/MS. The modified QuEChERS protocol applying a freeze-out followed by dSPE with PSA+C18 and SPE clean-up with Z-Sep was selected because it provided the highest number of pesticides with mean recoveries in the 70-120% range, as well as relative standard deviations (RSDs) typically below 20% (12.2% on average) and ensured much better removal of co-extracted matrix compounds of paramount importance in routine analysis. Limits of quantification at levels as low as 5μgkg(-1) were obtained for the majority of the pesticides. The proposed methodology was applied to the analysis of 41 pollen bee samples from different areas in Spain. Pesticides considered potentially toxic to bees (DL50<2μg/bee) were detected in some samples with concentrations up to 72.7μgkg(-1), which could negatively affect honeybee health. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Standardization of chemical analytical techniques for pyrolysis bio-oil: history, challenges, and current status of methods

    DOE PAGES

    Ferrell, Jack R.; Olarte, Mariefel V.; Christensen, Earl D.; ...

    2016-07-05

    Here, we discuss the standardization of analytical techniques for pyrolysis bio-oils, including the current status of methods, and our opinions on future directions. First, the history of past standardization efforts is summarized, and both successful and unsuccessful validation of analytical techniques highlighted. The majority of analytical standardization studies to-date has tested only physical characterization techniques. In this paper, we present results from an international round robin on the validation of chemical characterization techniques for bio-oils. Techniques tested included acid number, carbonyl titrations using two different methods (one at room temperature and one at 80 °C), 31P NMR for determination ofmore » hydroxyl groups, and a quantitative gas chromatography–mass spectrometry (GC-MS) method. Both carbonyl titration and acid number methods have yielded acceptable inter-laboratory variabilities. 31P NMR produced acceptable results for aliphatic and phenolic hydroxyl groups, but not for carboxylic hydroxyl groups. As shown in previous round robins, GC-MS results were more variable. Reliable chemical characterization of bio-oils will enable upgrading research and allow for detailed comparisons of bio-oils produced at different facilities. Reliable analytics are also needed to enable an emerging bioenergy industry, as processing facilities often have different analytical needs and capabilities than research facilities. We feel that correlations in reliable characterizations of bio-oils will help strike a balance between research and industry, and will ultimately help to -determine metrics for bio-oil quality. Lastly, the standardization of additional analytical methods is needed, particularly for upgraded bio-oils.« less

  3. Standardization of chemical analytical techniques for pyrolysis bio-oil: history, challenges, and current status of methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferrell, Jack R.; Olarte, Mariefel V.; Christensen, Earl D.

    Here, we discuss the standardization of analytical techniques for pyrolysis bio-oils, including the current status of methods, and our opinions on future directions. First, the history of past standardization efforts is summarized, and both successful and unsuccessful validation of analytical techniques highlighted. The majority of analytical standardization studies to-date has tested only physical characterization techniques. In this paper, we present results from an international round robin on the validation of chemical characterization techniques for bio-oils. Techniques tested included acid number, carbonyl titrations using two different methods (one at room temperature and one at 80 °C), 31P NMR for determination ofmore » hydroxyl groups, and a quantitative gas chromatography–mass spectrometry (GC-MS) method. Both carbonyl titration and acid number methods have yielded acceptable inter-laboratory variabilities. 31P NMR produced acceptable results for aliphatic and phenolic hydroxyl groups, but not for carboxylic hydroxyl groups. As shown in previous round robins, GC-MS results were more variable. Reliable chemical characterization of bio-oils will enable upgrading research and allow for detailed comparisons of bio-oils produced at different facilities. Reliable analytics are also needed to enable an emerging bioenergy industry, as processing facilities often have different analytical needs and capabilities than research facilities. We feel that correlations in reliable characterizations of bio-oils will help strike a balance between research and industry, and will ultimately help to -determine metrics for bio-oil quality. Lastly, the standardization of additional analytical methods is needed, particularly for upgraded bio-oils.« less

  4. Zwitterionic, cationic, and anionic fluorinated chemicals in aqueous film forming foam formulations and groundwater from U.S. military bases by nonaqueous large-volume injection HPLC-MS/MS.

    PubMed

    Backe, Will J; Day, Thomas C; Field, Jennifer A

    2013-05-21

    A new analytical method was developed to quantify 26 newly-identified and 21 legacy (e.g. perfluoroalkyl carboxylates, perfluoroalkyl sulfonates, and fluorotelomer sulfonates) per and polyfluorinated alkyl substances (PFAS) in groundwater and aqueous film forming foam (AFFF) formulations. Prior to analysis, AFFF formulations were diluted into methanol and PFAS in groundwater were micro liquid-liquid extracted. Methanolic dilutions of AFFF formulations and groundwater extracts were analyzed by large-volume injection (900 μL) high-performance liquid chromatography tandem mass spectrometry. Orthogonal chromatography was performed using cation exchange (silica) and anion exchange (propylamine) guard columns connected in series to a reverse-phase (C18) analytical column. Method detection limits for PFAS in groundwater ranged from 0.71 ng/L to 67 ng/L, and whole-method accuracy ranged from 96% to 106% for analytes for which matched authentic analytical standards were available. For analytes without authentic analytical standards, whole-method accuracy ranged from 78 % to 144 %, and whole-method precision was less than 15 % relative standard deviation for all analytes. A demonstration of the method on groundwater samples from five military bases revealed eight of the 26 newly-identified PFAS present at concentrations up to 6900 ng/L. The newly-identified PFAS represent a minor fraction of the fluorinated chemicals in groundwater relative to legacy PFAS. The profiles of PFAS in groundwater differ from those found in fluorotelomer- and electrofluorination-based AFFF formulations, which potentially indicates environmental transformation of PFAS.

  5. The National Shipbuilding Research Program. Development of a Quick TBT Analytical Method

    DTIC Science & Technology

    2000-08-16

    Development of a Quick TBT Analytical Method 09/25/2000 Page 3 of 38 Executive Summary Concern about the toxic effect of tributyltin have caused the...paints, developed in the 1960s, contains the organotin tributyltin ( TBT ), which has been proven to cause deformations in oysters and sex changes in...measured response (area counts) for tributyltin in deionized distilled water. Final Report – Development of a Quick TBT Analytical Method 09/25/2000

  6. The rise of environmental analytical chemistry as an interdisciplinary activity.

    PubMed

    Brown, Richard

    2009-07-01

    Modern scientific endeavour is increasingly delivered within an interdisciplinary framework. Analytical environmental chemistry is a long-standing example of an interdisciplinary approach to scientific research where value is added by the close cooperation of different disciplines. This editorial piece discusses the rise of environmental analytical chemistry as an interdisciplinary activity and outlines the scope of the Analytical Chemistry and the Environmental Chemistry domains of TheScientificWorldJOURNAL (TSWJ), and the appropriateness of TSWJ's domain format in covering interdisciplinary research. All contributions of new data, methods, case studies, and instrumentation, or new interpretations and developments of existing data, case studies, methods, and instrumentation, relating to analytical and/or environmental chemistry, to the Analytical and Environmental Chemistry domains, are welcome and will be considered equally.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, D.W.; Heinrich, R.R.; Graczyk, D.G.

    The purpose of this report is to summarize the activities of the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) for Fiscal Year 1991 (October 1990 through September 1991). This is the eighth annual report for the ACL. The Analytical Chemistry Laboratory is a full-cost-recovery service center, with the primary mission of providing a broad range of analytical chemistry support services to the scientific and engineering programs at ANL. In addition, the ACL conducts a research program in analytical chemistry, works on instrumental and methods development, and provides analytical services for governmental, educational, and industrial organizations. The ACL handlesmore » a wide range of analytical problems, from routine standard analyses to unique problems that require significant development of methods and techniques.« less

  8. Analytic strategies to evaluate the association of time-varying exposures to HIV-related outcomes: Alcohol consumption as an example.

    PubMed

    Cook, Robert L; Kelso, Natalie E; Brumback, Babette A; Chen, Xinguang

    2016-01-01

    As persons with HIV are living longer, there is a growing need to investigate factors associated with chronic disease, rate of disease progression and survivorship. Many risk factors for this high-risk population change over time, such as participation in treatment, alcohol consumption and drug abuse. Longitudinal datasets are increasingly available, particularly clinical data that contain multiple observations of health exposures and outcomes over time. Several analytic options are available for assessment of longitudinal data; however, it can be challenging to choose the appropriate analytic method for specific combinations of research questions and types of data. The purpose of this review is to help researchers choose the appropriate methods to analyze longitudinal data, using alcohol consumption as an example of a time-varying exposure variable. When selecting the optimal analytic method, one must consider aspects of exposure (e.g. timing, pattern, and amount) and outcome (fixed or time-varying), while also addressing minimizing bias. In this article, we will describe several analytic approaches for longitudinal data, including developmental trajectory analysis, generalized estimating equations, and mixed effect models. For each analytic strategy, we describe appropriate situations to use the method and provide an example that demonstrates the use of the method. Clinical data related to alcohol consumption and HIV are used to illustrate these methods.

  9. Analytical methods for quantitation of prenylated flavonoids from hops.

    PubMed

    Nikolić, Dejan; van Breemen, Richard B

    2013-01-01

    The female flowers of hops ( Humulus lupulus L.) are used as a flavoring agent in the brewing industry. There is growing interest in possible health benefits of hops, particularly as estrogenic and chemopreventive agents. Among the possible active constituents, most of the attention has focused on prenylated flavonoids, which can chemically be classified as prenylated chalcones and prenylated flavanones. Among chalcones, xanthohumol (XN) and desmethylxanthohumol (DMX) have been the most studied, while among flavanones, 8-prenylnaringenin (8-PN) and 6-prenylnaringenin (6-PN) have received the most attention. Because of the interest in medicinal properties of prenylated flavonoids, there is demand for accurate, reproducible and sensitive analytical methods to quantify these compounds in various matrices. Such methods are needed, for example, for quality control and standardization of hop extracts, measurement of the content of prenylated flavonoids in beer, and to determine pharmacokinetic properties of prenylated flavonoids in animals and humans. This review summarizes currently available analytical methods for quantitative analysis of the major prenylated flavonoids, with an emphasis on the LC-MS and LC-MS-MS methods and their recent applications to biomedical research on hops. This review covers all methods in which prenylated flavonoids have been measured, either as the primary analytes or as a part of a larger group of analytes. The review also discusses methodological issues relating to the quantitative analysis of these compounds regardless of the chosen analytical approach.

  10. A surrogate analyte method to determine D-serine in mouse brain using liquid chromatography-tandem mass spectrometry.

    PubMed

    Kinoshita, Kohnosuke; Jingu, Shigeji; Yamaguchi, Jun-ichi

    2013-01-15

    A bioanalytical method for determining endogenous d-serine levels in the mouse brain using a surrogate analyte and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. [2,3,3-(2)H]D-serine and [(15)N]D-serine were used as a surrogate analyte and an internal standard, respectively. The surrogate analyte was spiked into brain homogenate to yield calibration standards and quality control (QC) samples. Both endogenous and surrogate analytes were extracted using protein precipitation followed by solid phase extraction. Enantiomeric separation was achieved on a chiral crown ether column with an analysis time of only 6 min without any derivatization. The column eluent was introduced into an electrospray interface of a triple-quadrupole mass spectrometer. The calibration range was 1.00 to 300 nmol/g, and the method showed acceptable accuracy and precision at all QC concentration levels from a validation point of view. In addition, the brain d-serine levels of normal mice determined using this method were the same as those obtained by a standard addition method, which is time-consuming but is often used for the accurate measurement of endogenous substances. Thus, this surrogate analyte method should be applicable to the measurement of d-serine levels as a potential biomarker for monitoring certain effects of drug candidates on the central nervous system. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Quantifying the measurement uncertainty of results from environmental analytical methods.

    PubMed

    Moser, J; Wegscheider, W; Sperka-Gottlieb, C

    2001-07-01

    The Eurachem-CITAC Guide Quantifying Uncertainty in Analytical Measurement was put into practice in a public laboratory devoted to environmental analytical measurements. In doing so due regard was given to the provisions of ISO 17025 and an attempt was made to base the entire estimation of measurement uncertainty on available data from the literature or from previously performed validation studies. Most environmental analytical procedures laid down in national or international standards are the result of cooperative efforts and put into effect as part of a compromise between all parties involved, public and private, that also encompasses environmental standards and statutory limits. Central to many procedures is the focus on the measurement of environmental effects rather than on individual chemical species. In this situation it is particularly important to understand the measurement process well enough to produce a realistic uncertainty statement. Environmental analytical methods will be examined as far as necessary, but reference will also be made to analytical methods in general and to physical measurement methods where appropriate. This paper describes ways and means of quantifying uncertainty for frequently practised methods of environmental analysis. It will be shown that operationally defined measurands are no obstacle to the estimation process as described in the Eurachem/CITAC Guide if it is accepted that the dominating component of uncertainty comes from the actual practice of the method as a reproducibility standard deviation.

  12. 100-B/C Target Analyte List Development for Soil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R.W. Ovink

    2010-03-18

    This report documents the process used to identify source area target analytes in support of the 100-B/C remedial investigation/feasibility study addendum to DOE/RL-2008-46. This report also establishes the analyte exclusion criteria applicable for 100-B/C use and the analytical methods needed to analyze the target analytes.

  13. Standardization, evaluation and early-phase method validation of an analytical scheme for batch-consistency N-glycosylation analysis of recombinant produced glycoproteins.

    PubMed

    Zietze, Stefan; Müller, Rainer H; Brecht, René

    2008-03-01

    In order to set up a batch-to-batch-consistency analytical scheme for N-glycosylation analysis, several sample preparation steps including enzyme digestions and fluorophore labelling and two HPLC-methods were established. The whole method scheme was standardized, evaluated and validated according to the requirements on analytical testing in early clinical drug development by usage of a recombinant produced reference glycoprotein (RGP). The standardization of the methods was performed by clearly defined standard operation procedures. During evaluation of the methods, the major interest was in the loss determination of oligosaccharides within the analytical scheme. Validation of the methods was performed with respect to specificity, linearity, repeatability, LOD and LOQ. Due to the fact that reference N-glycan standards were not available, a statistical approach was chosen to derive accuracy from the linearity data. After finishing the validation procedure, defined limits for method variability could be calculated and differences observed in consistency analysis could be separated into significant and incidental ones.

  14. Development and validation of a multi-analyte method for the regulatory control of carotenoids used as feed additives in fish and poultry feed.

    PubMed

    Vincent, Ursula; Serano, Federica; von Holst, Christoph

    2017-08-01

    Carotenoids are used in animal nutrition mainly as sensory additives that favourably affect the colour of fish, birds and food of animal origin. Various analytical methods exist for their quantification in compound feed, reflecting the different physico-chemical characteristics of the carotenoid and the corresponding feed additives. They may be natural products or specific formulations containing the target carotenoids produced by chemical synthesis. In this study a multi-analyte method was developed that can be applied to the determination of all 10 carotenoids currently authorised within the European Union for compound feedingstuffs. The method functions regardless of whether the carotenoids have been added to the compound feed via natural products or specific formulations. It is comprised of three steps: (1) digestion of the feed sample with an enzyme; (2) pressurised liquid extraction; and (3) quantification of the analytes by reversed-phase HPLC coupled to a photodiode array detector in the visible range. The method was single-laboratory validated for poultry and fish feed covering a mass fraction range of the target analyte from 2.5 to 300 mg kg - 1 . The following method performance characteristics were obtained: the recovery rate varied from 82% to 129% and precision expressed as the relative standard deviation of intermediate precision varied from 1.6% to 15%. Based on the acceptable performance obtained in the validation study, the multi-analyte method is considered fit for the intended purpose.

  15. Enhanced spot preparation for liquid extractive sampling and analysis

    DOEpatents

    Van Berkel, Gary J.; King, Richard C.

    2015-09-22

    A method for performing surface sampling of an analyte, includes the step of placing the analyte on a stage with a material in molar excess to the analyte, such that analyte-analyte interactions are prevented and the analyte can be solubilized for further analysis. The material can be a matrix material that is mixed with the analyte. The material can be provided on a sample support. The analyte can then be contacted with a solvent to extract the analyte for further processing, such as by electrospray mass spectrometry.

  16. Advances in NMR Spectroscopy for Lipid Oxidation Assessment

    USDA-ARS?s Scientific Manuscript database

    Although there are many analytical methods developed for the assessment of lipid oxidation, different analytical methods often give different, sometimes even contradictory, results. The reason for this inconsistency is that although there are many different kinds of oxidation products, most methods ...

  17. SAMPLING AND ANALYSIS OF MERCURY IN CRUDE OIL

    EPA Science Inventory

    Sampling and analytical procedures used to determine total mercury content in crude oils were examined. Three analytical methods were compared with respect to accuracy, precision and detection limit. The combustion method and a commercial extraction method were found adequate to...

  18. Determination of steroid hormones and related compounds in filtered and unfiltered water by solid-phase extraction, derivatization, and gas chromatography with tandem mass spectrometry

    USGS Publications Warehouse

    Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.; Barber, Larry B.

    2012-01-01

    A new analytical method has been developed and implemented at the U.S. Geological Survey National Water Quality Laboratory that determines a suite of 20 steroid hormones and related compounds in filtered water (using laboratory schedule 2434) and in unfiltered water (using laboratory schedule 4434). This report documents the procedures and initial performance data for the method and provides guidance on application of the method and considerations of data quality in relation to data interpretation. The analytical method determines 6 natural and 3 synthetic estrogen compounds, 6 natural androgens, 1 natural and 1 synthetic progestin compound, and 2 sterols: cholesterol and 3--coprostanol. These two sterols have limited biological activity but typically are abundant in wastewater effluents and serve as useful tracers. Bisphenol A, an industrial chemical used primarily to produce polycarbonate plastic and epoxy resins and that has been shown to have estrogenic activity, also is determined by the method. A technique referred to as isotope-dilution quantification is used to improve quantitative accuracy by accounting for sample-specific procedural losses in the determined analyte concentration. Briefly, deuterium- or carbon-13-labeled isotope-dilution standards (IDSs), all of which are direct or chemically similar isotopic analogs of the method analytes, are added to all environmental and quality-control and quality-assurance samples before extraction. Method analytes and IDS compounds are isolated from filtered or unfiltered water by solid-phase extraction onto an octadecylsilyl disk, overlain with a graded glass-fiber filter to facilitate extraction of unfiltered sample matrices. The disks are eluted with methanol, and the extract is evaporated to dryness, reconstituted in solvent, passed through a Florisil solid-phase extraction column to remove polar organic interferences, and again evaporated to dryness in a reaction vial. The method compounds are reacted with activated -methyl--trimethylsilyl trifluoroacetamide at 65 degrees Celsius for 1 hour to form trimethylsilyl or trimethylsilyl-enol ether derivatives that are more amenable to gas chromatographic separation than the underivatized compounds. Analysis is carried out by gas chromatography with tandem mass spectrometry using calibration standards that are derivatized concurrently with the sample extracts. Analyte concentrations are quantified relative to specific IDS compounds in the sample, which directly compensate for procedural losses (incomplete recovery) in the determined and reported analyte concentrations. Thus, reported analyte concentrations (or analyte recoveries for spiked samples) are corrected based on recovery of the corresponding IDS compound during the quantification process. Recovery for each IDS compound is reported for each sample and represents an absolute recovery in a manner comparable to surrogate recoveries for other organic methods used by the National Water Quality Laboratory. Thus, IDS recoveries provide a useful tool for evaluating sample-specific analytical performance from an absolute mass recovery standpoint. IDS absolute recovery will differ and typically be lower than the corresponding analyte’s method recovery in spiked samples. However, additional correction of reported analyte concentrations is unnecessary and inappropriate because the analyte concentration (or recovery) already is compensated for by the isotope-dilution quantification procedure. Method analytes were spiked at 10 and 100 nanograms per liter (ng/L) for most analytes (10 times greater spike levels were used for bisphenol A and 100 times greater spike levels were used for 3--coprostanol and cholesterol) into the following validation-sample matrices: reagent water, wastewater-affected surface water, a secondary-treated wastewater effluent, and a primary (no biological treatment) wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100 percent, with overall relative standard deviation of 28 percent. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples and analyzed in 2009–2010 ranged from 84–104 percent, with relative standard deviations of 6–36 percent. Concentrations for two analytes, equilin and progesterone, are reported as estimated because these analytes had excessive bias or variability, or both. Additional database coding is applied to other reported analyte data as needed, based on sample-specific IDS recovery performance. Detection levels were derived statistically by fortifying reagent water at six different levels (0.1 to 4 ng/L) and range from about 0.4 to 4 ng/L for 16 analytes. Interim reporting levels applied to analytes in this report range from 0.8 to 8 ng/L. Bisphenol A and the sterols (cholesterol and 3-beta-coprostanol) were consistently detected in laboratory and field blanks. The minimum reporting levels were set at 100 ng/L for bisphenol A and at 200 ng/L for the two sterols to prevent any bias associated with the presence of these compounds in the blanks. A minimum reporting level of 2 ng/L was set for 11-ketotestosterone to minimize false positive risk from an interfering siloxane compound emanating as chromatographic-column bleed, from vial septum material, or from other sources at no more than 1 ng/L.

  19. A generic standard additions based method to determine endogenous analyte concentrations by immunoassays to overcome complex biological matrix interference.

    PubMed

    Pang, Susan; Cowen, Simon

    2017-12-13

    We describe a novel generic method to derive the unknown endogenous concentrations of analyte within complex biological matrices (e.g. serum or plasma) based upon the relationship between the immunoassay signal response of a biological test sample spiked with known analyte concentrations and the log transformed estimated total concentration. If the estimated total analyte concentration is correct, a portion of the sigmoid on a log-log plot is very close to linear, allowing the unknown endogenous concentration to be estimated using a numerical method. This approach obviates conventional relative quantification using an internal standard curve and need for calibrant diluent, and takes into account the individual matrix interference on the immunoassay by spiking the test sample itself. This technique is based on standard additions for chemical analytes. Unknown endogenous analyte concentrations within even 2-fold diluted human plasma may be determined reliably using as few as four reaction wells.

  20. Semi-analytical solutions of the Schnakenberg model of a reaction-diffusion cell with feedback

    NASA Astrophysics Data System (ADS)

    Al Noufaey, K. S.

    2018-06-01

    This paper considers the application of a semi-analytical method to the Schnakenberg model of a reaction-diffusion cell. The semi-analytical method is based on the Galerkin method which approximates the original governing partial differential equations as a system of ordinary differential equations. Steady-state curves, bifurcation diagrams and the region of parameter space in which Hopf bifurcations occur are presented for semi-analytical solutions and the numerical solution. The effect of feedback control, via altering various concentrations in the boundary reservoirs in response to concentrations in the cell centre, is examined. It is shown that increasing the magnitude of feedback leads to destabilization of the system, whereas decreasing this parameter to negative values of large magnitude stabilizes the system. The semi-analytical solutions agree well with numerical solutions of the governing equations.

Top