Albuquerque, Marco Antonio; Gaia, Bruno Felipe; Cavalcanti, Marcelo Gusmão Paraíso
2011-08-01
The aim of this study was to determine the applicability of multislice and cone-beam computerized tomography (CT) in the assessment of bone defects in patients with oral clefts. Bone defects were produced in 9 dry skulls to mimic oral clefts. All defects were modeled with wax. The skulls were submitted to multislice and cone-beam CT. Subsequently, physical measurements were obtained by the Archimedes principle of water displacement of wax models. The results demonstrated that multislice and cone-beam CT showed a high efficiency rate and were considered to be effective for volumetric assessment of bone defects. It was also observed that both CT modalities showed excellent results with high reliability in the study of the volume of bone defects, with no difference in performance between them. The clinical applicability of our research has shown these CT modalities to be immediate and direct, and they is important for the diagnosis and therapeutic process of patients with oral cleft. Copyright © 2011 Mosby, Inc. All rights reserved.
Dos Santos, Denise Takehana; Costa e Silva, Adriana Paula Andrade; Vannier, Michael Walter; Cavalcanti, Marcelo Gusmão Paraiso
2004-12-01
The purpose of this study was to demonstrate the sensitivity and specificity of multislice computerized tomography (CT) for diagnosis of maxillofacial fractures following specific protocols using an independent workstation. The study population consisted of 56 patients with maxillofacial fractures who were submitted to a multislice CT. The original data were transferred to an independent workstation using volumetric imaging software to generate axial images and simultaneous multiplanar (MPR) and 3-dimensional (3D-CT) volume rendering reconstructed images. The images were then processed and interpreted by 2 examiners using the following protocols independently of each other: axial, MPR/axial, 3D-CT images, and the association of axial/MPR/3D images. The clinical/surgical findings were considered the gold standard corroborating the diagnosis of the fractures and their anatomic localization. The statistical analysis was carried out using validity and chi-squared tests. The association of axial/MPR/3D images indicated a higher sensitivity (range 95.8%) and specificity (range 99%) than the other methods regarding the analysis of all regions. CT imaging demonstrated high specificity and sensitivity for maxillofacial fractures. The association of axial/MPR/3D-CT images added important information in relationship to other CT protocols.
Imaging anatomy of the vestibular and visual systems.
Gunny, Roxana; Yousry, Tarek A
2007-02-01
This review will outline the imaging anatomy of the vestibular and visual pathways, using computed tomography and magnetic resonance imaging, with emphasis on the more recent developments in neuroimaging. Technical advances in computed tomography and magnetic resonance imaging, such as the advent of multislice computed tomography and newer magnetic resonance imaging techniques such as T2-weighted magnetic resonance cisternography, have improved the imaging of the vestibular and visual pathways, allowing better visualization of the end organs and peripheral nerves. Higher field strength magnetic resonance imaging is a promising tool, which has been used to evaluate and resolve fine anatomic detail in vitro, as in the labyrinth. Advanced magnetic resonance imaging techniques such as functional magnetic resonance imaging and diffusion tractography have been used to identify cortical areas of activation and associated white matter pathways, and show potential for the future identification of complex neuronal relays involved in integrating these pathways. The assessment of the various components of the vestibular and the visual systems has improved with more detailed research on the imaging anatomy of these systems, the advent of high field magnetic resonance scanners and multislice computerized tomography, and the wider use of specific techniques such as tractography which displays white matter tracts not directly accessible until now.
Ren, Jiayin; Zhou, Zhongwei; Li, Peng; Tang, Wei; Guo, Jixiang; Wang, Hu; Tian, Weidong
2016-09-01
This study aimed to evaluate an innovative workflow for maxillofacial fracture surgery planning and surgical splint designing. The maxillofacial multislice computerized tomography (MSCT) data and dental cone beam computerized tomography (CBCT) data both were obtained from 40 normal adults and 58 adults who suffered fractures. The each part of the CBCT dentition image was registered into MSCT image by the use of the iterative closest point algorithm. Volume evaluation of the virtual splints that were designed by the registered MSCT images and MSCT images of the same object was performed. Eighteen patients (group 1) were operated without any splint. Twenty-one (group 2) and 19 patients (group 3) used the splints designed according to the MSCT images and registered MSCT images, respectively. The authors' results showed that the mean errors between the 2 models ranged from 0.53 to 0.92 mm and the RMS errors ranged from 0.38 to 0.69 mm in fracture patients. The mean errors between the 2 models ranged from 0.47 to 0.85 mm and the RMS errors ranged from 0.33 to 0.71 mm in normal adults. 72.22% patients in group 1 recovered occlusion. 85.71% patients in group 2, and 94.73% patients in group 3 reconstructed occlusion. There was a statistically significant difference between the MSCT images based splints' volume and the registered MSCT splints' volume in patients (P <0.05). The MSCT images based splints' volume was statistically significantly distinct from the registered MSCT splints' volume in normal adults (P <0.05). There was a statistically significant difference between the MSCT images based splints' volume and the registered MSCT splints' volume in patients and normal adults (P <0.05). The occlusion recovery rate of group 3 was better than that of group 1 and group 2. The way of integrating CBCT images into MSCT images for splints designing was feasible. The volume of the splints designed by MSCT images tended to be smaller than the splints designed by the integrated MSCT images. The patients operated with splints tended to regain occlusion. The patients who were operated with the splints which were designed according to registered MSCT images tended to get occlusal recovered.
Multislice Computed Tomography Accurately Detects Stenosis in Coronary Artery Bypass Conduits
Duran, Cihan; Sagbas, Ertan; Caynak, Baris; Sanisoglu, Ilhan; Akpinar, Belhhan; Gulbaran, Murat
2007-01-01
The aim of this study was to evaluate the accuracy of multislice computed tomography in detecting graft stenosis or occlusion after coronary artery bypass grafting, using coronary angiography as the standard. From January 2005 through May 2006, 25 patients (19 men and 6 women; mean age, 54 ± 11.3 years) underwent diagnostic investigation of their bypass grafts by multislice computed tomography within 1 month of coronary angiography. The mean time elapsed after coronary artery bypass grafting was 6.2 years. In these 25 patients, we examined 65 bypass conduits (24 arterial and 41 venous) and 171 graft segments (the shaft, proximal anastomosis, and distal anastomosis). Compared with coronary angiography, the segment-based sensitivity, specificity, and positive and negative predictive values of multislice computed tomography in the evaluation of stenosis were 89%, 100%, 100%, and 99%, respectively. The patency rate for multislice compu-ted tomography was 85% (55/65: 3 arterial and 7 venous grafts were occluded), with 100% sensitivity and specificity. From these data, we conclude that multislice computed tomography can accurately evaluate the patency and stenosis of bypass grafts during outpatient follow-up. PMID:17948078
Virtopsy: postmortem imaging of laryngeal foreign bodies.
Oesterhelweg, Lars; Bolliger, Stephan A; Thali, Michael J; Ross, Steffen
2009-05-01
Death from corpora aliena in the larynx is a well-known entity in forensic pathology. The correct diagnosis of this cause of death is difficult without an autopsy, and misdiagnoses by external examination alone are common. To determine the postmortem usefulness of modern imaging techniques in the diagnosis of foreign bodies in the larynx, multislice computed tomography, magnetic resonance imaging, and postmortem full-body computed tomography-angiography were performed. Three decedents with a suspected foreign body in the larynx underwent the 3 different imaging techniques before medicolegal autopsy. Multislice computed tomography has a high diagnostic value in the noninvasive localization of a foreign body and abnormalities in the larynx. The differentiation between neoplasm or soft foreign bodies (eg, food) is possible, but difficult, by unenhanced multislice computed tomography. By magnetic resonance imaging, the discrimination of the soft tissue structures and soft foreign bodies is much easier. In addition to the postmortem multislice computed tomography, the combination with postmortem angiography will increase the diagnostic value. Postmortem, cross-sectional imaging methods are highly valuable procedures for the noninvasive detection of corpora aliena in the larynx.
Dysphagia lusorium in elderly: A case report
Kantarceken, Bulent; Bulbuloglu, Ertan; Yuksel, Murvet; Cetinkaya, Ali
2004-01-01
AIM: Late unset of dysphagia due to vascular abnormalities is a rare condition. We aimed to present a case of right subclavian artery abnormalities caused dysphagia in the elderly. METHODS: A 68-year-old female was admitted with dysphagia seven months ago. Upper endoscopic procedures and routine examinations could not demonstrate any etiology. Multislice computed thorax tomography was performed for probable extra- esophagial lesions. RESULTS: Multislice computed thorax tomography showed right subclavian artery abnormality and esophagial compression with this aberrant artery. CONCLUSION: Causes of dysphagia in the elderly are commonly malignancies, strictures and/or motility disorders. If routine examinations and endoscopic procedures fail to show any etiology, rare vascular abnormalities can be considered in such patients. Multislice computed tomography is a usefull choice in such conditions. PMID:15285045
Castorina, Sergio; Luca, Tonia; Privitera, Giovanna; Riccioli, Vincenzo
2010-01-01
In this paper, we describe two cases of anomalous origin of the left coronary artery and two cases of aneurysm on the left coronary artery. Detailed three-dimensional images were acquired by the multislice computed tomography (MSCT) SOMATOM Sensation Cardiac 64 during clinical studies of cardiac diseases. Copyright 2010. Published by Elsevier Inc.
Yerli, Hasan; Avci, Suat; Aydin, Erdinc; Arikan, Unser
2010-03-01
Metaplastic Warthin tumor is a rarely seen subtype of Warthin tumor. It can resemble squamous carcinomas histopathologically, because it contains atypical squamous cells on the necrotic surface. Making a diagnosis can become easier by knowing this entity of Warthin tumor well and by correlating the radiologic findings with pathology. In this case presentation, imaging features of a metaplastic Warthin tumor are presented together with its histopathologic findings. When a solid mass with peripheral enhancing cystic-necrotic component and well defined contour and capsule that shows early enhancement and washout is identified with imaging methods in parotid gland, metaplastic Warthin tumor should be indicated in the differential diagnosis before the histopathologic evaluation. Copyright 2010 Mosby, Inc. All rights reserved.
Gerloni, Alessandro; Cavalli, Fabio; Costantinides, Fulvio; Costantinides, Fulvia; Bonetti, Stefano; Paganelli, Corrado
2009-06-01
The aim of the study was to provide a paleopathologic and radiologic overview of the jaws and teeth of 3 Egyptian mummies preserved in the Civic Museum of History and Art in Trieste. Computerized tomography (CT) imaging and postprocessing techniques were used to examine the oral structures. A 16-slice CT scanner was used (Aquilion 16; Toshiba Medical Systems Europe, Zoetermeer, The Netherlands). Scans were obtained at high resolution. Orthogonal-plane and 3-dimensional (3D) reconstructions were created along with curved reconstructions of the lower and upper jaws. Determination of decayed/missing teeth (DMT) and decayed/missing/tooth surfaces (DMTs) were made with 3D images. Analyses revealed differences in the embalming techniques and state of preservation of the bodies. Marked wear of the occlusal surfaces was a characteristic finding in all of the mummies. The DMT and DMTs were low compared with values for contemporary populations. Two mummies had fully erupted third molars. All mummies exhibited bone changes consistent with periodontitis. The CT evaluations of the oral structures of the mummies provided insight into the dental status and oral diseases of these ancient Egyptians. The low DMT and DMTs values and indications of periodontitis may be associated with the lifestyle of these Egyptians. The fully erupted and well aligned third molars may represent a morphologic adaptation of the arches to the muscular activity associated with grinding tough foods.
Mahran, Abeer H; AboEl-Fotouh, Mona M
2008-10-01
The purpose of this study was to compare the effects of 3 different instruments used to prepare curved root canals on the remaining cervical dentin thickness and total amount of dentin removed from root canals during instrumentation by using multislice computed tomography. Mesiobuccal canals of 45 mandibular first molars with curvature between 30-40 degrees were divided into 3 equal groups: ProTaper, Hero Shaper, and Gates Glidden Bur with Flex-R hand file. Cervical dentin thickness and canal volume were measured before and after instrumentation by using multislice computed tomography and image analysis software. The results indicated that ProTaper removed significantly less cervical dentin from distal wall of the root (dangerous zone) than HeroShaper and Gates Glidden Bur (P < .05). The total dentin removed during canal instrumentation was significantly more with ProTaper system (P < .05).
Wurmb, Thomas Erik; Frühwald, Peter; Hopfner, Wittiko; Roewer, Norbert; Brederlau, Jörg
2007-11-01
In our hospital, whole-body multislice computed tomography is used as the primary diagnostic tool in patients with suspected multiple trauma. A triage rule is used for its indication. We have retrospectively analyzed data of sedated, intubated and ventilated patients consecutively admitted to our trauma center to assess whether the triage rule can help identify patients with severe trauma (injury severity score > or = 16). We have found that overtriage (injury severity score < 16) occurs in 30%, and undertriage occurs in 6% of patients. Although we have found the triage rule to be highly sensitive, this results in a high rate of overtriage. Until we know more about the most relevant and independent predictive factors, sole reliance upon multislice computed tomography in triaging suspected polytrauma victims will imply the risk to overscan many patients.
Eskandarloo, Amir; Abdinian, Mehrdad; Salemi, Fatemeh; Hashemzadeh, Zahra; Safaei, Mehran
2012-01-01
Background: Bone density measurement in a radiographic view is a valuable method for evaluating the density of bone quality before performing some dental procedures such as, dental implant placements. It seems that Cone-Beam Computed Tomography (CBCT) can be used as a diagnostic tool for evaluating the density of the bone, prior to any treatment, as the reported radiation dose in this method is minimal. The aim of this study is to investigate the effect of object location on the density measurement in CBCT versus Multislice computed tomography (CT). Materials and Methods: In an experimental study, three samples with similar dimensions, but different compositions, different densities (Polyethylene, Polyamide, Polyvinyl Chloride), and three bone pieces of different parts of the mandibular bone were imaged in three different positions by CBCT and Multislice CT sets. The average density value was computed for each sample in each position. Then the data obtained from each CBCT was converted to a Hounsfield unit and evaluated using a single variable T analysis. A P value <0.05 was considered to be significant. Results: The density in a Multislice CT is stable in the form of a Hounsfield Number, but this density is variable in the images acquired through CBCT, and the change in the position results in significant changes in the density. In this study, a statistically significant difference (P value = 0.000) has been observed for the position of the sample and its density in CBCT in comparison to Multislice CT. Conclusions: Density values in CBCT are not real because they are affected by the position of the object in the machine. PMID:23814567
Darwish, Ragaa T; Abdel-Aziz, Manal H; El Nekiedy, Abdel-Aziz M; Sobh, Zahraa K
2017-11-01
In forensic sciences to determine one's sex is quite important during the identity defining stage. The reliability of sex determination depends on the completeness of the remains and the degree of sexual dimorphism inherent in the population. Computed Tomography is the imaging modality of choice for two- and three-dimensional documentation and analysis of many autopsy findings. The aim of the present work was to assess the reliability of Three-dimensional Multislice Computed Tomography (3D MSCT) to determine sexual dimorphism from certain chest measurements; sternum and fourth rib using the 3D MSCT and to develop equations for sex determination from these bones among adult Egyptians sample. The present study was performed on 60 adult Egyptians. Their age ranged from 21 up to 74 years and they were equally divided between both sexes. Sixty virtual chests (reconstructed Multislice Computed Tomography 3D images) were examined for detection of Sternal measurements; Manubrium length (ML), Sternal body length (BL), Manubrium width (MW), Sternal body widths(BWa&BWb), Sternal area (SA) [(ML + BL) × (MW + BWa + BWb)/3]and Fourth rib width (FRW). All the studied measurements were significantly higher in males than in females. Multiple regression analysis was used to and three significant regression equations were developed for predicting sex using the different studied chest measurements; the sternal measurements, the sternal area and the widths of the right and left fourth ribs with their accuracies 96.67%.95.0%.72.68% respectively. Sterunm and fourth rib width revealed significant metric sex differences with the use of Multislice Computed Tomography 3D images thus provide a great advantage in the analysis of skeletal remains and badly decomposed bodies. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
An Application of Computerized Axial Tomography (CAT) Technology to Mass Raid Tracking
1989-08-01
ESD-TR-89-305 MTR-10542 An Application of Computerized Axial Tomography ( CAT ) Technology to Mass Raid Tracking By John K. Barr August 1989...NO 11. TITLE (Include Security Classification) An Application of Computerized Axial Tomography ( CAT ) Technology to Mass Raid Tracking 12...by block number) Computerized Axial Tomography ( CAT ) Scanner Electronic Support Measures (ESM) Fusion (continued) 19. ABSTRACT (Continue on
Muslimov, R Sh; Sharifullin, F A; Chernaia, N R; Novruzbekov, M S; Kokov, L S
2015-01-01
Acute traumatic aortic rupture is associated with extremely high mortality rates and requires emergency diagnosis and treatment. This clinical example shows the role of multislice spiral computed tomography in the emergency diagnosis of rupture of two large arterial vessels in severe concomitant injury. It presents the benefits of this rapid and noninvasive imaging technique, an algorithm of the study and the semiotics of injuries in patients with suspected traumatic aortic rupture. The paper also shows the importance of this method in defining treatment policy and then in the assessment of the results of the performed correction.
Analysis of intensity variability in multislice and cone beam computed tomography.
Nackaerts, Olivia; Maes, Frederik; Yan, Hua; Couto Souza, Paulo; Pauwels, Ruben; Jacobs, Reinhilde
2011-08-01
The aim of this study was to evaluate the variability of intensity values in cone beam computed tomography (CBCT) imaging compared with multislice computed tomography Hounsfield units (MSCT HU) in order to assess the reliability of density assessments using CBCT images. A quality control phantom was scanned with an MSCT scanner and five CBCT scanners. In one CBCT scanner, the phantom was scanned repeatedly in the same and in different positions. Images were analyzed using registration to a mathematical model. MSCT images were used as a reference. Density profiles of MSCT showed stable HU values, whereas in CBCT imaging the intensity values were variable over the profile. Repositioning of the phantom resulted in large fluctuations in intensity values. The use of intensity values in CBCT images is not reliable, because the values are influenced by device, imaging parameters and positioning. © 2011 John Wiley & Sons A/S.
Thali, Michael J; Schweitzer, Wolf; Yen, Kathrin; Vock, Peter; Ozdoba, Christoph; Spielvogel, Elke; Dirnhofer, Richard
2003-03-01
The goal of this study was the full-body documentation of a gunshot wound victim with multislice helical computed tomography for subsequent comparison with the findings of the standard forensic autopsy. Complete volume data of the head, neck, and trunk were acquired by use of two acquisitions of less than 1 minute of total scanning time. Subsequent two-dimensional multiplanar reformations and three-dimensional shaded surface display reconstructions helped document the gunshot-created skull fractures and brain injuries, including the wound track, and the intracerebral bone fragments. Computed tomography also demonstrated intracardiac air embolism and pulmonary aspiration of blood resulting from bullet wound-related trauma. The "digital autopsy," even when postprocessing time was added, was more rapid than the classic forensic autopsy and, based on the nondestructive approach, offered certain advantages in comparison with the forensic autopsy.
Wang, Xing-Lu; Huang, Ying; Li, Qu-Bei; Dai, Ji-Hong
2013-09-01
To investigate and compare the diagnostic values of bronchoscopy and multi-slice spiral computed tomography (CT) for congenital dysplasia of the respiratory system in infants. Analysis was performed on the clinical data, bronchoscopic findings and multi-slice spiral CT findings of 319 infants (≤1 years old) who underwent bronchoscopy and/or multi-slice spiral CT and were diagnosed with congenital dysplasia of the respiratory system. A total of 476 cases of congenital dysplasia of the respiratory system were found in the 319 infants, including primary dysplasia of the respiratory system (392 cases) and compressive dysplasia of the respiratory system (84 cases). Of the 392 cases of primary dysplasia of the respiratory system, 225 (57.4%) were diagnosed by bronchoscopy versus 167 (42.6%) by multi-slice spiral CT. There were significant differences in etiological diagnosis between bronchoscopy and multi-slice spiral CT in infants with congenital dysplasia of the respiratory system (P<0.05). All 76 cases of primary dysplasia of the respiratory system caused by tracheobronchomalacia were diagnosed by bronchoscopy and all 17 cases of primary dysplasia of the respiratory system caused by lung tissue dysplasia were diagnosed by multi-slice spiral CT. Of the 84 cases of compressive dysplasia of the respiratory system, 74 cases were diagnosed by multi-slice spiral CT and only 10 cases were diagnosed by bronchoscopy. Compared with multi-slice spiral CT, bronchoscopy can detect primary dysplasia of the respiratory system more directly. Bronchoscopy is valuable in the confirmed diagnosis of tracheobronchomalacia. Multi-slice spiral CT has a higher diagnostic value for lung tissue dysplasia than bronchoscopy.
Tosaka, Masahiko; Nagaki, Tomohito; Honda, Fumiaki; Takahashi, Katsumasa; Yoshimoto, Yuhei
2015-11-01
Intraoperative computed tomography (iCT) is a reliable method for the detection of residual tumour, but previous single-slice low-resolution computed tomography (CT) without coronal or sagittal reconstructions was not of adequate quality for clinical use. The present study evaluated the results of multi-slice iCT-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma. This retrospective study included 30 consecutive patients with newly diagnosed or recurrent pituitary macroadenoma with supradiaphragmatic extension who underwent endoscopic transsphenoidal surgery using iCT (eTSS+iCT group), and control 30 consecutive patients who underwent conventional endoscope-assisted transsphenoidal surgery (cTSS group). The tumour volume was calculated by multiplying the tumour area by the slice thickness. Visual acuity and visual field were estimated by the visual impairment score (VIS). The resection extent, (preoperative tumour volume - postoperative residual tumour volume)/preoperative tumour volume, was 98.9% (median) in the eTSS+iCT group and 91.7% in the cTSS group, and had significant difference between the groups (P = 0.04). Greater than 95 and >90% removal rates were significantly higher in the eTSS+iCT group than in the cTSS group (P = 0.02 and P = 0.001, respectively). However, improvement in VIS showed no significant difference between the groups. The rate of complications also showed no significant difference. Multi-slice iCT-assisted endoscopic transsphenoidal surgery may improve the resection extent of pituitary macroadenoma. Multi-slice iCT may have advantages over intraoperative magnetic resonance imaging in less expensive, short acquisition time, and that special protection against magnetic fields is not needed.
Can computerized tomography accurately stage childhood renal tumors?
Abdelhalim, Ahmed; Helmy, Tamer E; Harraz, Ahmed M; Abou-El-Ghar, Mohamed E; Dawaba, Mohamed E; Hafez, Ashraf T
2014-07-01
Staging of childhood renal tumors is crucial for treatment planning and outcome prediction. We sought to identify whether computerized tomography could accurately predict the local stage of childhood renal tumors. We retrospectively reviewed our database for patients diagnosed with childhood renal tumors and treated surgically between 1990 and 2013. Inability to retrieve preoperative computerized tomography, intraoperative tumor spillage and nonWilms childhood renal tumors were exclusion criteria. Local computerized tomography stage was assigned by a single experienced pediatric radiologist blinded to the pathological stage, using a consensus similar to the Children's Oncology Group Wilms tumor staging system. Tumors were stratified into up-front surgery and preoperative chemotherapy groups. The radiological stage of each tumor was compared to the pathological stage. A total of 189 tumors in 179 patients met inclusion criteria. Computerized tomography staging matched pathological staging in 68% of up-front surgery (70 of 103), 31.8% of pre-chemotherapy (21 of 66) and 48.8% of post-chemotherapy scans (42 of 86). Computerized tomography over staged 21.4%, 65.2% and 46.5% of tumors in the up-front surgery, pre-chemotherapy and post-chemotherapy scans, respectively, and under staged 10.7%, 3% and 4.7%. Computerized tomography staging was more accurate in tumors managed by up-front surgery (p <0.001) and those without extracapsular extension (p <0.001). The validity of computerized tomography staging of childhood renal tumors remains doubtful. This staging is more accurate for tumors treated with up-front surgery and those without extracapsular extension. Preoperative computerized tomography can help to exclude capsular breach. Treatment strategy should be based on surgical and pathological staging to avoid the hazards of inaccurate staging. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Into the decomposed body-forensic digital autopsy using multislice-computed tomography.
Thali, M J; Yen, K; Schweitzer, W; Vock, P; Ozdoba, C; Dirnhofer, R
2003-07-08
It is impossible to obtain a representative anatomical documentation of an entire body using classical X-ray methods, they subsume three-dimensional bodies into a two-dimensional level. We used the novel multislice-computed tomography (MSCT) technique in order to evaluate a case of homicide with putrefaction of the corpse before performing a classical forensic autopsy. This non-invasive method showed gaseous distension of the decomposing organs and tissues in detail as well as a complex fracture of the calvarium. MSCT also proved useful in screening for foreign matter in decomposing bodies, and full-body scanning took only a few minutes. In conclusion, we believe postmortem MSCT imaging is an excellent vizualisation tool with great potential for forensic documentation and evaluation of decomposed bodies.
Freire-Maia, B; Machado, V deC; Valerio, C S; Custódio, A L N; Manzi, F R; Junqueira, J L C
2017-03-01
The aim of this study was to compare the accuracy of linear measurements of the distance between the mandibular cortical bone and the mandibular canal using 64-detector multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT). It was sought to evaluate the reliability of these examinations in detecting the mandibular canal for use in bilateral sagittal split osteotomy (BSSO) planning. Eight dry human mandibles were studied. Three sites, corresponding to the lingula, the angle, and the body of the mandible, were selected. After the CT scans had been obtained, the mandibles were sectioned and the bone segments measured to obtain the actual measurements. On analysis, no statistically significant difference was found between the measurements obtained through MSCT and CBCT, or when comparing the measurements from these scans with the actual measurements. It is concluded that the images obtained by CT scan, both 64-detector multi-slice and cone beam, can be used to obtain accurate linear measurements to locate the mandibular canal for preoperative planning of BSSO. The ability to correctly locate the mandibular canal during BSSO will reduce the occurrence of neurosensory disturbances in the postoperative period. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; Motroni, Alessandro; van der Stelt, Paul; Wismeijer, Daniel
2012-01-01
To assess the reliability of cone beam computed tomography (CBCT) voxel gray value measurements using Hounsfield units (HU) derived from multislice computed tomography (MSCT) as a clinical reference (gold standard). Ten partially edentulous human mandibular cadavers were scanned by two types of computed tomography (CT) modalities: multislice CT and cone beam CT. On MSCT scans, eight regions of interest (ROI) designating the site for preoperative implant placement were selected in each mandible. The datasets from both CT systems were matched using a three-dimensional (3D) registration algorithm. The mean voxel gray values of the region around the implant sites were compared between MSCT and CBCT. Significant differences between the mean gray values obtained by CBCT and HU by MSCT were found. In all the selected ROIs, CBCT showed higher mean values than MSCT. A strong correlation (R=0.968) between mean voxel gray values of CBCT and mean HU of MSCT was determined. Voxel gray values from CBCT deviate from actual HU units. However, a strong linear correlation exists, which may permit deriving actual HU units from CBCT using linear regression models.
Hahn, Wolfram; Fricke-Zech, Susanne; Fialka-Fricke, Julia; Dullin, Christian; Zapf, Antonia; Gruber, Rudolf; Sennhenn-kirchner, Sabine; Kubein-Meesenburg, Dietmar; Sadat-Khonsari, Reza
2009-09-01
An investigation was conducted to compare the image quality of prototype flat-panel volume computed tomography (fpVCT) and multislice computed tomography (MSCT) of suture structures. Bone samples were taken from the midpalatal suture of 5 young (16 weeks) and 5 old (200 weeks) Sus scrofa domestica and fixed in formalin solution. An fpVCT prototype and an MSCT were used to obtain images of the specimens. The facial reformations were assessed by 4 observers using a 1 (excellent) to 5 (poor) rating scale for the weighted criteria visualization of the suture structure. A linear mixed model was used for statistical analysis. Results with P < .05 were considered to be statistically significant. The visualization of the suture of young specimens was significantly better than that of older animals (P < .001). The visualization of the suture with fpVCT was significantly better than that with MSCT (P < .001). Compared with MSCT, fpVCT produces superior results in the visualization of the midpalatal suture in a Sus scrofa domestica model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnston, H; UT Southwestern Medical Center, Dallas, TX; Hilts, M
Purpose: To commission a multislice computed tomography (CT) scanner for fast and reliable readout of radiation therapy (RT) dose distributions using CT polymer gel dosimetry (PGD). Methods: Commissioning was performed for a 16-slice CT scanner using images acquired through a 1L cylinder filled with water. Additional images were collected using a single slice machine for comparison purposes. The variability in CT number associated with the anode heel effect was evaluated and used to define a new slice-by-slice background image subtraction technique. Image quality was assessed for the multislice system by comparing image noise and uniformity to that of the singlemore » slice machine. The consistency in CT number across slices acquired simultaneously using the multislice detector array was also evaluated. Finally, the variability in CT number due to increasing x-ray tube load was measured for the multislice scanner and compared to the tube load effects observed on the single slice machine. Results: Slice-by-slice background subtraction effectively removes the variability in CT number across images acquired simultaneously using the multislice scanner and is the recommended background subtraction method when using a multislice CT system. Image quality for the multislice machine was found to be comparable to that of the single slice scanner. Further study showed CT number was consistent across image slices acquired simultaneously using the multislice detector array for each detector configuration of the slice thickness examined. In addition, the multislice system was found to eliminate variations in CT number due to increasing x-ray tube load and reduce scanning time by a factor of 4 when compared to imaging a large volume using a single slice scanner. Conclusion: A multislice CT scanner has been commissioning for CT PGD, allowing images of an entire dose distribution to be acquired in a matter of minutes. Funding support provided by the Natural Sciences and Engineering Research Council of Canada (NSERC)« less
Ma, X J; Tao, L; Chen, X; Li, W; Peng, Z Y; Chen, Y; Jin, J; Zhang, X L; Xiong, Q F; Zhong, Z L; Chen, X F
2015-02-13
Three-dimensional (3D) reconstruction and rapid prototyping technology (RPT) of multislice spiral computed tomography angiography (CTA) was applied to prepare physical models of the heart and ventricular septal defects of tetralogy of Fallot (ToF) patients in order to explore their applications in the diagnosis and treatment of this complex heart disease. CTA data of 35 ToF patients were collected to prepare l:l 3D solid models using digital 3D reconstruction and RPT, and the resultant models were used intraoperatively as reference. The operations of all 35 patients were completed under the guidance of the 3D solid model, without difficulty. Intraoperative findings of the patients were consistent with the morphological and size changes of the 3D solid model, and no significant differences were found between the patches obtained from the 3D solid model and the actual intraoperative measurements (t = 0.83, P = 0.412). 3D reconstruction and RPT of multislice spiral CTA can accurately and intuitively reflect the anatomy of ventricular septal defects in ToF patients, providing the foundation for a solid model of the complex congenital heart.
Iosca, Simona; Lumia, Domenico; Bracchi, Elena; Duka, Ejona; De Bon, Monica; Lekaj, Manjola; Uccella, Stefano; Ghezzi, Fabio; Fugazzola, Carlo
2013-01-01
This study evaluates retrospectively the accuracy and reproducibility of multislice computed tomography with colon water distension (MSCT-c) in diagnosing bowel (BE) and ureteral (UE) endometriosis. Sixty-four patients underwent MSCT-c and videolaparoscopic surgery. Two radiologists reviewed MSCT-c examinations: sensitivity and specificity were calculated, considering histological exam as reference standard. In the BE cases, the degree of bowel wall infiltration was also assessed. Sensitivity and specificity for both readers were 100% and 97.6% for BE and 72.2% and 100% for UE; the interobserver agreement was excellent. The degree of bowel wall involvement was correctly defined in 90.9% of cases. MSCT-c is an accurate and reproducible technique but-considering the age of the patients-delivers a nonnegligible radiation dose. © 2013 Elsevier Inc. All rights reserved.
Hirschmann, Michael T.; Schmid, Rahel; Dhawan, Ranju; Skarvan, Jiri; Rasch, Helmut; Friederich, Niklaus F.; Emery, Roger
2011-01-01
With the cases described, we strive to introduce single photon emission computerized tomography in combination with conventional computer tomography (SPECT/CT) to shoulder surgeons, illustrate the possible clinical value it may offer as new diagnostic radiologic modality, and discuss its limitations. SPECT/CT may facilitate the establishment of diagnosis, process of decision making, and further treatment for complex shoulder pathologies. Some of these advantages were highlighted in cases that are frequently seen in most shoulder clinics. PMID:22058640
Webb, S M; Ruscalleda, J; Schwarzstein, D; Calaf-Alsina, J; Rovira, A; Matos, G; Puig-Domingo, M; de Leiva, A
1992-05-01
We wished to analyse the relative value of computerized tomography and magnetic resonance in patients referred for evaluation of pituitary and parasellar lesions. We performed a separate evaluation by two independent neuroradiologists of computerized tomography and magnetic resonance images ordered numerically and anonymously, with no clinical data available. We studied 40 patients submitted for hypothalamic-pituitary study; 31 were carried out preoperatively, of which histological confirmation later became available in 14. The remaining nine patients were evaluated postoperatively. Over 40 parameters relating to the bony margins, cavernous sinuses, carotid arteries, optic chiasm, suprasellar cisterns, pituitary, pituitary stalk and extension of the lesion were evaluated. These reports were compared with the initial ones offered when the scans were ordered, and with the final diagnosis. Concordance between initial computerized tomography and magnetic resonance was observed in 27 cases (67.5%); among the discordant cases computerized tomography showed the lesion in two, magnetic resonance in 10, while in the remaining case reported to harbour a microadenoma on computerized tomography the differential diagnosis between a true TSH-secreting microadenoma and pituitary resistance to thyroid hormones is still unclear. Both neuroradiologists coincided in their reports in 32 patients (80%); when the initial report was compared with those of the neuroradiologists, concordance was observed with at least one of them in 34 instances (85%). Discordant results were observed principally in microadenomas secreting ACTH or PRL and in delayed puberty. In the eight patients with Cushing's disease (histologically confirmed in six) magnetic resonance was positive in five and computerized tomography in two; the abnormal image correctly identified the side of the lesion at surgery. In patients referred for evaluation of Cushing's syndrome or hyperprolactinaemia (due to microadenomas) or after surgery, magnetic resonance is clearly preferable to computerized tomography. In macroadenomas both scans are equally diagnostic but magnetic resonance offers more information on pituitary morphology and neighbouring structures. Nevertheless, there are cases in which the results of computerized tomography and magnetic resonance will complement each other, since different parameters are analysed with each examination and discordant results are encountered.
Erovic, Boban M; Chan, Harley H L; Daly, Michael J; Pothier, David D; Yu, Eugene; Coulson, Chris; Lai, Philip; Irish, Jonathan C
2014-01-01
Conventional computed tomography (CT) imaging is the standard imaging technique for temporal bone diseases, whereas cone-beam CT (CBCT) imaging is a very fast imaging tool with a significant less radiation dose compared with conventional CT. We hypothesize that a system for intraoperative cone-beam CT provides comparable image quality to diagnostic CT for identifying temporal bone anatomical landmarks in cadaveric specimens. Cross-sectional study. University tertiary care facility. Twenty cadaveric temporal bones were affixed into a head phantom and scanned with both a prototype cone-beam CT C-arm and multislice helical CT. Imaging performance was evaluated by 3 otologic surgeons and 1 head and neck radiologist. Participants were presented images in a randomized order and completed landmark identification questionnaires covering 21 structures. CBCT and multislice CT have comparable performance in identifying temporal structures. Three otologic surgeons indicated that CBCT provided statistically equivalent performance for 19 of 21 landmarks, with CBCT superior to CT for the chorda tympani and inferior for the crura of the stapes. Subgroup analysis showed that CBCT performed superiorly for temporal bone structures compared with CT. The radiologist rated CBCT and CT as statistically equivalent for 18 of 21 landmarks, with CT superior to CBCT for the crura of stapes, chorda tympani, and sigmoid sinus. CBCT provides comparable image quality to conventional CT for temporal bone anatomical sites in cadaveric specimens. Clinical applications of low-dose CBCT imaging in surgical planning, intraoperative guidance, and postoperative assessment are promising but require further investigation.
Mishra, Anuj; Ehtuish, Ehtuish F
2006-06-01
To assess the renal vessel anatomy, compare the findings with the perioperative findings, to determine the sensitivity of multislice computed tomography (CT) angiography in the work-up of live potential donors and to discuss and compare the results of the present study with the reported results using single slice CT, magnetic resonance (MRI) and conventional angiography (CA). Retrospective analysis of the angiographic data of 118 of prospective live related kidney donors was carried out from October 2004 to August 2005 at the National Organ Transplant Centre, Tripoli Central Hospital, Libya. All donors underwent renal angiography on multislice (16-slice) CT scan using 80 cc intravenous contrast with 1.25 mm slice thickness followed by maximum intensity projection (MIP) and volume rendering techniques (VRT) post-processing algorithms. The number of vessels, vessel bifurcation, vessel morphology and venous anatomy were analyzed and the findings were compared with the surgical findings. Multislice spiral CT angiography (MSCTA) showed clear delineation of the main renal arteries in all donors with detailed vessel morphology. The study revealed 100% sensitivity in detection of accessory renal vessels, with an overall incidence of 26.7%, which is the most common distribution in the parahilar region. The present study showed 100% sensitivity in the visualization and detection of main and accessory renal vessels. These results were comparable with conventional angiography which has so far been considered as the gold standard and were found superior in specificity and accuracy to the use of single slice CT (SSCT) and MR in the angiographic work-up of live renal donors. Due to improved detection of accessory vessels less than 2 mm in diameter, a higher incidence of aberrant vessels was seen on the right side as has been suggested so far.
Akten, H Serpil; Kilic, Hatice; Celik, Bulent; Erbas, Gonca; Isikdogan, Zeynep; Turktas, Haluk; Kokturk, Nurdan
2018-04-25
This study aimed to evaluate the diagnostic yield of fiberoptic bronchoscopic (FOB) transbronchial biopsy and its relation with quantitative findings of high resolution computerized tomography (HRCT). A total of 83 patients, 19 males and 64 females with a mean age of 45.1 years diagnosed with sarcoidosis with complete records of high resolution computerized tomography were retrospectively recruited during the time period from Feb 2005 to Jan 2015. High resolution computerized tomography scans were retrospectively assessed in random order by an experienced observer without knowledge of the bronchoscopic results or lung function tests. According to the radiological staging with HRCT, 2.4% of the patients (n=2) were stage 0, 19.3% (n=16) were stage 1, 72.3% (n=60) were stage 2 and 6.0% (n=5) were stage 3. This study showed that transbronchial lung biopsy showed positive results in 39.7% of the stage I or II sarcoidosis patients who were diagnosed by bronchoscopy. Different high resolution computerized tomography patterns and different scores of involvement did make a difference in the diagnostic accuracy of transbronchial biopsy (p=0.007). Creative Commons Attribution License
Naitoh, Munetaka; Nakahara, Kino; Suenaga, Yutaka; Gotoh, Kenichi; Kondo, Shintaro; Ariji, Eiichiro
2010-01-01
The most common diagnostic imaging modalities for cross-sectional imaging in dental implant planning are currently cone-beam computed tomography (CBCT) and multislice CT (MSCT). However, clinical differences between CBCT and MSCT in this task have not been fully clarified. In this investigation, the detection of fine anatomical structures in the mandible was assessed and compared between CBCT and MSCT images. The sample consisted of 28 patients who had undergone CBCT and MSCT. The bifid mandibular canal in the mandibular ramus, accessory mental and buccal foramina, and median and lateral lingual bony canals were observed in 2-D images, and the findings were compared between CBCT and MSCT. Four of 19 canals observed in CBCT were not observed in MSCT images. Three accessory mental foramina in 2 patients and 28 lateral lingual bony canals in 18 patients were observed consistently using the two methods. Depiction of fine anatomic features in the mandible associated with neurovascular structures is consistent between CBCT and MSCT images. Copyright 2010 Mosby, Inc. All rights reserved.
Pryor, Alan; Ophus, Colin; Miao, Jianwei
2017-10-25
Simulation of atomic-resolution image formation in scanning transmission electron microscopy can require significant computation times using traditional methods. A recently developed method, termed plane-wave reciprocal-space interpolated scattering matrix (PRISM), demonstrates potential for significant acceleration of such simulations with negligible loss of accuracy. In this paper, we present a software package called Prismatic for parallelized simulation of image formation in scanning transmission electron microscopy (STEM) using both the PRISM and multislice methods. By distributing the workload between multiple CUDA-enabled GPUs and multicore processors, accelerations as high as 1000 × for PRISM and 15 × for multislice are achieved relative to traditionalmore » multislice implementations using a single 4-GPU machine. We demonstrate a potentially important application of Prismatic, using it to compute images for atomic electron tomography at sufficient speeds to include in the reconstruction pipeline. Prismatic is freely available both as an open-source CUDA/C++ package with a graphical user interface and as a Python package, PyPrismatic.« less
Pryor, Alan; Ophus, Colin; Miao, Jianwei
2017-01-01
Simulation of atomic-resolution image formation in scanning transmission electron microscopy can require significant computation times using traditional methods. A recently developed method, termed plane-wave reciprocal-space interpolated scattering matrix (PRISM), demonstrates potential for significant acceleration of such simulations with negligible loss of accuracy. Here, we present a software package called Prismatic for parallelized simulation of image formation in scanning transmission electron microscopy (STEM) using both the PRISM and multislice methods. By distributing the workload between multiple CUDA-enabled GPUs and multicore processors, accelerations as high as 1000 × for PRISM and 15 × for multislice are achieved relative to traditional multislice implementations using a single 4-GPU machine. We demonstrate a potentially important application of Prismatic , using it to compute images for atomic electron tomography at sufficient speeds to include in the reconstruction pipeline. Prismatic is freely available both as an open-source CUDA/C++ package with a graphical user interface and as a Python package, PyPrismatic .
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pryor, Alan; Ophus, Colin; Miao, Jianwei
Simulation of atomic-resolution image formation in scanning transmission electron microscopy can require significant computation times using traditional methods. A recently developed method, termed plane-wave reciprocal-space interpolated scattering matrix (PRISM), demonstrates potential for significant acceleration of such simulations with negligible loss of accuracy. In this paper, we present a software package called Prismatic for parallelized simulation of image formation in scanning transmission electron microscopy (STEM) using both the PRISM and multislice methods. By distributing the workload between multiple CUDA-enabled GPUs and multicore processors, accelerations as high as 1000 × for PRISM and 15 × for multislice are achieved relative to traditionalmore » multislice implementations using a single 4-GPU machine. We demonstrate a potentially important application of Prismatic, using it to compute images for atomic electron tomography at sufficient speeds to include in the reconstruction pipeline. Prismatic is freely available both as an open-source CUDA/C++ package with a graphical user interface and as a Python package, PyPrismatic.« less
ERIC Educational Resources Information Center
Balottin, Umberto; And Others
1989-01-01
The study of computerized tomography brain-scan findings with 45 autistic and 19 control subjects concluded that autism is nonspecifically associated with brain-scan abnormalities, and that other nonorganic, as well as organic, factors should be taken into account. (Author/DB)
[The clinical economic analysis of the methods of ischemic heart disease diagnostics].
Kalashnikov, V Iu; Mitriagina, S N; Syrkin, A L; Poltavskaia, M G; Sorokina, E G
2007-01-01
The clinical economical analysis was applied to assess the application of different techniques of ischemic heart disease diagnostics - the electro-cardiographic monitoring, the treadmill-testing, the stress-echo cardiographic with dobutamine, the single-photon computerized axial tomography with load, the multi-spiral computerized axial tomography with coronary arteries staining in patients with different initial probability of disease occurrence. In all groups, the best value of "cost-effectiveness" had the treadmill-test. The patients with low risk needed 17.4 rubles to precise the probability of ischemic heart disease occurrence at 1%. In the group with medium and high risk this indicator was 9.4 and 24.7 rubles correspondingly. It is concluded that to precise the probability of ischemic heart disease occurrence after tredmil-test in the patients with high probability it is appropriate to use the single-photon computerized axial tomography with load and in the case of patients with low probability the multi-spiral computerized axial tomography with coronary arteries staining.
Anthropometric and computerized tomographic measurements of lower extremity lean body mass.
Buckley, D C; Kudsk, K A; Rose, B S; Fatzinger, P; Koetting, C A; Schlatter, M
1987-02-01
The loss of lean muscle mass is one of the hallmarks of protein-calorie malnutrition. Anthropometry is a standardized technique used to assess the response of muscle mass to nutrition therapy by quantifying the muscle and fat compartments. That technique does not accurately reflect actual limb composition, whereas computerized tomography does. Twenty lower extremities on randomly chosen men and women patients were evaluated by anthropometry and computerized tomography. Total area, muscle plus bone area, total volume, and muscle plus bone volume were correlated, using Heymsfield's equation and computerized tomography-generated areas. Anthropometrics overestimated total and muscle plus bone cross-sectional areas at almost every level. Anthropometry overestimated total area and total volume by 5% to 10% but overestimated muscle plus bone area and muscle plus bone volume by as much as 40%. Anthropometry, while easily performed and useful in large population groups for epidemiological studies, offers a poor assessment of lower extremity composition. On the other hand, computerized tomography is also easily performed and, while impractical for large population groups, does offer an accurate assessment of the lower extremity tissue compartments and is an instrument that might be used in research on lean muscle mass.
Flach, Patricia M; Ross, Steffen G; Bolliger, Stephan A; Preiss, Ulrich S; Thali, Michael J; Spendlove, Danny
2010-01-01
In addition to the increasingly significant role of multislice computed tomography in forensic pathology, the performance of whole-body computed tomography angiography provides outstanding results. In this case, we were able to detect multiple injuries of the parenchymal organs in the upper abdomen as well as lesions of the brain parenchyma and vasculature of the neck. The radiologic findings showed complete concordance with the autopsy and even supplemented the autopsy findings in areas that are difficult to access via a manual dissection (such as the vasculature of the neck). This case shows how minimally invasive computed tomography angiography can serve as an invaluable adjunct to the classic autopsy procedure.
Initial clinical experience with computerized tomography of the body.
Stephens, D H; Sheedy, P F; Hattery, R R; Hartman, G W
1976-04-01
Computerized tomography of the body, now possible with an instrument that can complete a scan rapidly enough to permit patients to suspend respiration, adds an important new dimension to radiologic diagnosis. Cross-sectional antomy is uniquely reconstructed to provide accurate diagnostic information for various disorders throughout the body.
Fernandes, C L
2004-11-01
The volumes of the maxillary sinuses are of interest to surgeons operating endoscopically as variation in maxillary sinus volume may mean variation in anatomical landmarks. Other surgical disciplines, such as dentistry, maxillo-facial surgery and plastic surgery, may benefit from this information. To compare the maxillary sinus volumes of dried crania from cadavers of European and Zulu descent, with respect to ethnic group and gender. Helical, multislice computed tomography (CT) was performed using 1-mm coronal slices. The area for each slice was obtained by tracing the outline of each slice. The CT machine calculated a volume by totalling the slices for each sinus. Ethnic and gender variations were found in the different groups. It was found that European crania had significantly larger antral volumes than Zulu crania and men had larger volumes than women. Race and gender interaction was also assessed, as was maxillary sinus side. A variation in maxillary sinus volume between different ethnic groups and genders exists, and surgeons operating in this region should be aware of this.
Hou, Dailun; Qu, Huifang; Zhang, Xu; Li, Ning; Liu, Cheng; Ma, Xiangxing
2014-09-02
The aim of this study was to determine whether the diagnosis of intracranial tuberculosis (TB) can be improved when multi-slice computed tomography (MSCT) scans are taken with a 5-min delay after contrast media application. Pre- and post-contrast CT scans of the head were obtained from 30 patients using a 16-slice spiral CT. Dual-phase acquisition was performed immediately and 5 min after contrast agent injection. Diagnostic values of different images were compared using a scoring system applied by 2 experienced radiologists. We found 526 lesions in 30 patients, including 22 meningeal thickenings, 235 meningeal tuberculomas/tubercles, and 269 parenchymal tuberculomas/tubercles. Images obtained with 5-min delayed scan time were superior in terms of lesion size and meningeal thickening outlining in all disease types (P<0.01). The ability to distinguish between vascular sections from the cerebral sulcus and tubercle was also improved (P<0.01). Image acquisition with 5-min delay after contrast agent injection should be performed as a standard scanning protocol to diagnose intracranial TB.
Kleber, C; Oswald, B; Bail, H J; Haas, N P; Kandziora, F
2008-12-01
We present for the first time the use of contrast-enhanced multislice computed tomography in trauma care to detect acute myocardial infarction and verify it as the cause of a traffic accident. In addition to the case report, cardiac contusion, coronary dissection, and facets of insurance law are discussed. The determination of acute myocardial infarction, cardiac contusion, and coronary dissection can be challenging, but answers can be found in the medical history and accident details. The trauma surgeon in the emergency department must always be interested in clarifying the cause of trauma and keeping a secondary diagnosis in mind to strive for the goal of optimal and complete polytrauma care.
Kuusk, Teele; De Bruijn, Roderick; Brouwer, Oscar R; De Jong, Jeroen; Donswijk, Maarten; Grivas, Nikolaos; Hendricksen, Kees; Horenblas, Simon; Prevoo, Warner; Valdés Olmos, Renato A; Van Der Poel, Henk G; Van Rhijn, Bas W G; Wit, Esther M; Bex, Axel
2018-06-01
Lymphatic drainage from renal tumors is unpredictable. In vivo drainage studies of primary lymphatic landing sites may reveal the variability and dynamics of lymphatic connections. The purpose of this study was to investigate the lymphatic drainage pattern of renal tumors in vivo with single photon emission/computerized tomography after intratumor radiotracer injection. We performed a phase II, prospective, single arm study to investigate the distribution of sentinel nodes from renal tumors on single photon emission/computerized tomography. Patients with cT1-3 (less than 10 cm) cN0M0 renal tumors of any subtype were enrolled in analysis. After intratumor ultrasound guided injection of 0.4 ml 99m Tc-nanocolloid we performed preoperative imaging of sentinel nodes with lymphoscintigraphy and single photon emission/computerized tomography. Sentinel and locoregional nonsentinel nodes were resected with a γ probe combined with a mobile γ camera. The primary study end point was the location of sentinel nodes outside the locoregional retroperitoneal templates on single photon emission/computerized tomography. Using a Simon minimax 2-stage design to detect a 25% extralocoregional retroperitoneal template location of sentinel nodes on imaging at α = 0.05 and 80% power at least 40 patients with sentinel node imaging on single photon emission/computerized tomography were needed. Of the 68 patients 40 underwent preoperative single photon emission/computerized tomography of sentinel nodes and were included in primary end point analysis. Lymphatic drainage outside the locoregional retroperitoneal templates was observed in 14 patients (35%). Eight patients (20%) had supradiaphragmatic sentinel nodes. Sentinel nodes from renal tumors were mainly located in the respective locoregional retroperitoneal templates. Simultaneous sentinel nodes were located outside the suggested lymph node dissection templates, including supradiaphragmatic sentinel nodes in more than a third of the patients. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Zerbini, Talita; da Silva, Luiz Fernando Ferraz; Ferro, Antonio Carlos Gonçalves; Kay, Fernando Uliana; Junior, Edson Amaro; Pasqualucci, Carlos Augusto Gonçalves; do Nascimento Saldiva, Paulo Hilario
2014-01-01
OBJECTIVE: The aim of the present work is to analyze the differences and similarities between the elements of a conventional autopsy and images obtained from postmortem computed tomography in a case of a homicide stab wound. METHOD: Comparison between the findings of different methods: autopsy and postmortem computed tomography. RESULTS: In some aspects, autopsy is still superior to imaging, especially in relation to external examination and the description of lesion vitality. However, the findings of gas embolism, pneumothorax and pulmonary emphysema and the relationship between the internal path of the instrument of aggression and the entry wound are better demonstrated by postmortem computed tomography. CONCLUSIONS: Although multislice computed tomography has greater accuracy than autopsy, we believe that the conventional autopsy method is fundamental for providing evidence in criminal investigations. PMID:25518020
Yamashita, Hideomi; Okuma, Kae; Tada, Keiichiro; Shiraishi, Kenshiro; Takahashi, Wataru; Shibata-Mobayashi, Shino; Sakumi, Akira; Saotome, Naoya; Haga, Akihiro; Onoe, Tsuyoshi; Ino, Kenji; Akahane, Masaaki; Ohtomo, Kuni; Nakagawa, Keiichi
2012-10-01
To study the three-dimensional movement of internal tumor bed fiducial and breast skin markers, using 320-multislice computed tomography (CT); and to analyze intrafractional errors for breast cancer patients undergoing breast irradiation. This study examined 280 markers on the skin of the breast (200 markers) and on the primary tumor bed (80 markers) of 20 patients treated by external-beam photon radiotherapy. Motion assessment was analyzed in 41 respiratory phases during 20 s of cine CT in the radiotherapy position. To assess intrafractional errors resulting from respiratory motion, four-dimensional CT scans were acquired for 20 patients. Motion in the anterior-posterior (A/P) and superior-inferior (S/I) directions showed a strong correlation (|r| > 0.7) with the respiratory curve for most markers (79% and 70%, respectively). The average marker displacements between maximum and minimum value during 20 s for the 200 breast skin metal markers were 1.1 ± 0.3 mm, 2.1 ± 0.6 mm, and 1.6 ± 0.4 mm in the left-right, A/P, and S/I directions, respectively. For the 80 tumor bed clips, displacements were 0.9 ± 0.2 mm in left-right, 1.7 ± 0.5 mm in A/P, and 1.1 ± 0.3 mm in S/I. There was no significant difference in the motion between breast quadrant regions or between the primary site and the other regions. Motion in primary breast tumors was evaluated with 320-multislice CT. Very little change was detected during individual radiation treatment fractions. Copyright © 2012 Elsevier Inc. All rights reserved.
Wurmb, T E; Quaisser, C; Balling, H; Kredel, M; Muellenbach, R; Kenn, W; Roewer, N; Brederlau, J
2011-04-01
Whole-body multislice helical CT becomes increasingly important as a diagnostic tool in patients with multiple injuries. Time gain in multiple-trauma patients who require emergency surgery might improve outcome. The authors hypothesised that whole-body multislice computed tomography (MSCT) (MSCT trauma protocol) as the initial diagnostic tool reduces the interval to start emergency surgery (tOR) if compared to conventional radiography, combined with abdominal ultrasound and organ-focused CT (conventional trauma protocol). The second goal of the study was to investigate whether the diagnostic approach chosen has an impact on outcome. The authors' level 1 trauma centre uses whole-body MSCT for initial radiological diagnostic work-up for patients with suspected multiple trauma. Before the introduction of MSCT in 2004, a conventional approach was used. Group I: data of trauma patients treated with conventional trauma protocol from 2001 to 2003. Group II: data from trauma patients treated with whole-body MSCT trauma protocol from 2004 to 2006. tOR in group I (n=155) was 120 (90-150) min (median and IQR) and 105 (85-133) min (median and IQR) in group II (n=163), respectively (p<0.05). Patients of group II had significantly more serious injuries. No difference in outcome data was found. 14 patients died in both groups within the first 30 days; five of these died within the first 24 h. A whole-body MSCT-based diagnostic approach to multiple trauma shortens the time interval to start emergency surgery in patients with multiple injuries. Mortality remained unchanged in both groups. Patients of group II were more seriously injured; an improvement of outcome might be assumed.
Low contrast detection in abdominal CT: comparing single-slice and multi-slice tasks
NASA Astrophysics Data System (ADS)
Ba, Alexandre; Racine, Damien; Viry, Anaïs.; Verdun, Francis R.; Schmidt, Sabine; Bochud, François O.
2017-03-01
Image quality assessment is crucial for the optimization of computed tomography (CT) protocols. Human and mathematical model observers are increasingly used for the detection of low contrast signal in abdominal CT, but are frequently limited to the use of a single image slice. Another limitation is that most of them only consider the detection of a signal embedded in a uniform background phantom. The purpose of this paper was to test if human observer performance is significantly different in CT images read in single or multiple slice modes and if these differences are the same for anatomical and uniform clinical images. We investigated detection performance and scrolling trends of human observers of a simulated liver lesion embedded in anatomical and uniform CT backgrounds. Results show that observers don't take significantly benefit of additional information provided in multi-slice reading mode. Regarding the background, performances are moderately higher for uniform than for anatomical images. Our results suggest that for low contrast detection in abdominal CT, the use of multi-slice model observers would probably only add a marginal benefit. On the other hand, the quality of a CT image is more accurately estimated with clinical anatomical backgrounds.
Ganesan, Vishnu; De, Shubha; Shkumat, Nicholas; Marchini, Giovanni; Monga, Manoj
2018-02-01
Preoperative determination of uric acid stones from computerized tomography imaging would be of tremendous clinical use. We sought to design a software algorithm that could apply data from noncontrast computerized tomography to predict the presence of uric acid stones. Patients with pure uric acid and calcium oxalate stones were identified from our stone registry. Only stones greater than 4 mm which were clearly traceable from initial computerized tomography to final composition were included in analysis. A semiautomated computer algorithm was used to process image data. Average and maximum HU, eccentricity (deviation from a circle) and kurtosis (peakedness vs flatness) were automatically generated. These parameters were examined in several mathematical models to predict the presence of uric acid stones. A total of 100 patients, of whom 52 had calcium oxalate and 48 had uric acid stones, were included in the final analysis. Uric acid stones were significantly larger (12.2 vs 9.0 mm, p = 0.03) but calcium oxalate stones had higher mean attenuation (457 vs 315 HU, p = 0.001) and maximum attenuation (918 vs 553 HU, p <0.001). Kurtosis was significantly higher in each axis for calcium oxalate stones (each p <0.001). A composite algorithm using attenuation distribution pattern, average attenuation and stone size had overall 89% sensitivity, 91% specificity, 91% positive predictive value and 89% negative predictive value to predict uric acid stones. A combination of stone size, attenuation intensity and attenuation pattern from conventional computerized tomography can distinguish uric acid stones from calcium oxalate stones with high sensitivity and specificity. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Computerized tomography as a diagnostic aid in acute hemorrhagic leukoencephalitis.
Rothstein, T L; Shaw, C M
1983-03-01
Computerized tomography (CT) in a pathologically proven case of acute hemorrhagic leukoencephalitis (AHL) showed a mass effect and increased absorption coefficient in the right hemisphere within 18 hours of the onset of neurological symptoms. The changes corresponded to the site of white matter edema, necrosis, and petechial hemorrhages demonstrated postmortem. The early changes of CT reflect the hyperacute nature of AHL and differ from those of herpes simplex encephalitis.
Comprehensive Digital Imaging Network Project At Georgetown University Hospital
NASA Astrophysics Data System (ADS)
Mun, Seong K.; Stauffer, Douglas; Zeman, Robert; Benson, Harold; Wang, Paul; Allman, Robert
1987-10-01
The radiology practice is going through rapid changes due to the introduction of state-of-the-art computed based technologies. For the last twenty years we have witnessed the introduction of many new medical diagnostic imaging systems such as x-ray computed tomo-graphy, digital subtraction angiography (DSA), computerized nuclear medicine, single pho-ton emission computed tomography (SPECT), positron emission tomography (PET) and more re-cently, computerized digital radiography and nuclear magnetic resonance imaging (MRI). Other than the imaging systems, there has been a steady introduction of computed based information systems for radiology departments and hospitals.
De Cock, Jens; Zanca, Federica; Canning, John; Pauwels, Ruben; Hermans, Robert
2015-07-01
To evaluate image quality and radiation dose of a state of the art cone beam computed tomography (CBCT) system and a multislice computed tomography (MSCT) system in patients with sinonasal poliposis. In this retrospective study two radiologists evaluated 57 patients with sinonasal poliposis who underwent a CBCT or MSCT sinus examination, along with a control group of 90 patients with normal radiological findings. Tissue doses were measured using a phantom model with thermoluminescent dosimeters (TLD). Overall image quality in CBCT was scored significantly higher than in MSCT in patients with normal radiologic findings (p-value: 0.00001). In patients with sinonasal poliposis, MSCT scored significantly higher than CBCT (p-value: 0.00001). The average effective dose for MSCT was 42% higher compared to CBCT (108 μSv vs 63 μSv). CBCT and MSCT are both suited for the evaluation of sinonasal poliposis. In patients with sinonasal poliposis, clinically important structures of the paranasal sinuses can be better delineated with MSCT, whereas in patients without sinonasal poliposis, CBCT turns out to define the important structures of the sinonasal region better. However, given the lower radiation dose, CBCT can be considered for the evaluation of the sinonasal structures in patients with sinonasal poliposis. • CBCT and MSCT are both suited for evaluation of sinonasal poliposis. • Effective dose for MSCT was 42% higher compared to CBCT. • In patients with sinonasal poliposis, clinically important anatomical structures are better delineated with MSCT. • In patients with normal radiological findings, clinically important anatomical structures are better delineated with CBCT.
Matta, Ragai-Edward; von Wilmowsky, Cornelius; Neuhuber, Winfried; Lell, Michael; Neukam, Friedrich W; Adler, Werner; Wichmann, Manfred; Bergauer, Bastian
2016-05-01
Multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT) are indispensable imaging techniques in advanced medicine. The possibility of creating virtual and corporal three-dimensional (3D) models enables detailed planning in craniofacial and oral surgery. The objective of this study was to evaluate the impact of different scan protocols for CBCT and MSCT on virtual 3D model accuracy using a software-based evaluation method that excludes human measurement errors. MSCT and CBCT scans with different manufacturers' predefined scan protocols were obtained from a human lower jaw and were superimposed with a master model generated by an optical scan of an industrial noncontact scanner. To determine the accuracy, the mean and standard deviations were calculated, and t-tests were used for comparisons between the different settings. Averaged over 10 repeated X-ray scans per method and 19 measurement points per scan (n = 190), it was found that the MSCT scan protocol 140 kV delivered the most accurate virtual 3D model, with a mean deviation of 0.106 mm compared to the master model. Only the CBCT scans with 0.2-voxel resolution delivered a similar accurate 3D model (mean deviation 0.119 mm). Within the limitations of this study, it was demonstrated that the accuracy of a 3D model of the lower jaw depends on the protocol used for MSCT and CBCT scans. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Otolaryngology and ophthalmology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanafee, W.N.
A literature review with 227 references of the diagnostic use of computerized tomography for head and neck problems is presented. The anatomy, congenital malformations, infectious diseases, and nioplasms of the auditory organs, paranasal sinuses, pharynx, larynx and salivary glands are examined in detail. A major impetus to the use of computerized tomography has been the realization by the health care industry that CT scanning offers details of tumors in the head and neck area that are not available by other modalities. (KRM)
Right cervical aortic arch with aberrant left subclavian artery.
Tjang, Yanto S; Aramendi, José I; Crespo, Alejandro; Hamzeh, Gadah; Voces, Roberto; Rodríguez, Miguel A
2008-08-01
The combination of right cervical aortic arch, aberrant retroesophageal left subclavian artery originating from a Kommerell's diverticulum, and a ligamentum arteriosum, constitutes a rare form of vascular ring. Two patients aged 21 days and 54 years, who were diagnosed by multislice 3-dimensional computed tomography and magnetic resonance imaging, underwent surgical division of a vascular ring. The adult required resection of a Kommerell's aneurysm and subclavian artery reimplantation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen Yunyun; Li Zhenhua; Song Yang
2009-05-01
An extended model of the original Gladstone-Dale (G-D) equation is proposed for optical computerized tomography (OCT) diagnosis of flame flow fields. For the purpose of verifying the newly established model, propane combustion is used as a practical example for experiment, and moire deflection tomography is introduced with the probe wavelength 808 nm. The results indicate that the temperature based on the extended model is more accurate than that based on the original G-D equation. In a word, the extended model can be suitable for all kinds of flame flow fields whatever the components, temperature, and ionization are.
Bhatti, Aftab A; Chugtai, Aamir; Haslam, Philip; Talbot, David; Rix, David A; Soomro, Naeem A
2005-11-01
To prospectively compare the accuracy of multislice spiral computed tomographic angiography (CTA) and magnetic resonance angiography (MRA) in evaluating the renal vascular anatomy in potential living renal donors. Thirty-one donors underwent multislice spiral CTA and gadolinium-enhanced MRA. In addition to axial images, multiplanar reconstruction and maximum intensity projections were used to display the renal vascular anatomy. Twenty-four donors had a left laparoscopic donor nephrectomy (LDN), whereas seven had right open donor nephrectomy (ODN); LDN was only considered if the renal vascular anatomy was favourable on the left. CTA and MRA images were analysed by two radiologists independently. The radiological and surgical findings were correlated after the surgery. CTA showed 33 arteries and 32 veins (100% sensitivity) whereas MRA showed 32 arteries and 31 veins (97% sensitivity). CTA detected all five accessory renal arteries whereas MRA only detected one. CTA also identified all three accessory renal veins whereas MRA identified two. CTA had a sensitivity of 97% and 47% for left lumbar and left gonadal veins, whereas MRA had a sensitivity of 74% and 46%, respectively. Multislice spiral CTA with three-dimensional reconstruction was more accurate than MRA for both renal arterial and venous anatomy.
Computerized tomography using video recorded fluoroscopic images
NASA Technical Reports Server (NTRS)
Kak, A. C.; Jakowatz, C. V., Jr.; Baily, N. A.; Keller, R. A.
1975-01-01
A computerized tomographic imaging system is examined which employs video-recorded fluoroscopic images as input data. By hooking the video recorder to a digital computer through a suitable interface, such a system permits very rapid construction of tomograms.
Technology in the Assessment of Learning Disability.
ERIC Educational Resources Information Center
Bigler, Erin D.; Lajiness-O'Neill, Renee; Howes, Nancy-Louise
1998-01-01
Reviews recent neuroradiologic and brain imaging techniques in the assessment of learning disability. Technologies reviewed include computerized tomography; magnetic resonance imaging; electrophysiological and metabolic imaging; computerized electroencepholographic studies of evoked potentials, event-related potentials, spectral analysis, and…
Computerized tomography platform using beta rays
NASA Astrophysics Data System (ADS)
Paetkau, Owen; Parsons, Zachary; Paetkau, Mark
2017-12-01
A computerized tomography (CT) system using a 0.1 μCi Sr-90 beta source, Geiger counter, and low density foam samples was developed. A simple algorithm was used to construct images from the data collected with the beta CT scanner. The beta CT system is analogous to X-ray CT as both types of radiation are sensitive to density variations. This system offers a platform for learning opportunities in an undergraduate laboratory, covering topics such as image reconstruction algorithms, radiation exposure, and the energy dependence of absorption.
Schroeder, Janina; Peterschroeder, Andreas; Vaske, Bernhard; Butz, Thomas; Barth, Peter; Oldenburg, Olaf; Bitter, Thomas; Burchert, Wolfgang; Horstkotte, Dieter; Langer, Christoph
2009-11-01
In humans with normal hearts multi-slice computed tomography (MSCT) based volumetry was shown to correlate well with the gold standard, cardiac magnetic resonance imaging (CMR). We correlated both techniques in patients with various degrees of heart failure and reduced ejection fraction (HFREF) resulting from cardiac dilatation. Twenty-four patients with a left ventricular enddiastolic volume (LV-EDV) of C 150 ml measured by angiography underwent MSCT and CMR scanning for left and right ventricular (LV, RV) volumetry. MSCT based short cardiac axis views were obtained beginning at the cardiac base advancing to the apex. These were reconstructed in 20 different time windows of the RR-interval (0-95%) serving for identification of enddiastole (ED) and end-systole (ES) and for planimetry. ED and ES volumes and the ejection fraction (EF) were calculated for LV and RV. MSCT based volumetry was compared with CMR. MSCT based LV volumetry significantly correlates with CMR as follows: LV-EDV r = 0.94, LV-ESV r = 0.98 and LV-EF r = 0.93, but significantly overestimates LV-EDV and LV-ESV and underestimates EF (P \\ 0.0001). MSCT based RV volumetry significantly correlates with CMR as follows: RV-EDV r = 0.79, RVESV r = 0.78 and RV-EF r = 0.73, but again significantly overestimates RV-EDV and RV-ESV and underestimates RV-EF (P \\ 0.0001). When compared with CMR a continuous overestimation of volumes and underestimation of EF needs to be considered when applying MSCT in HFREF patients.
Naser, Asieh Zamani; Mehr, Bahar Behdad
2013-01-01
Cross- sectional tomograms have been used for optimal pre-operative planning of dental implant placement. The aim of the present study was to assess the accuracy of Cone Beam Computed Tomography (CBCT) measurements of specific distances around the mandibular canal by comparing them to those obtained from Multi-Slice Computed Tomography (MSCT) images. Ten hemi-mandible specimens were examined using CBCT and MSCT. Before imaging, wires were placed at 7 locations between the anterior margin of the third molar and the anterior margin of the second premolar as reference points. Following distances were measured by two observers on each cross-sectional CBCT and MSCT image: Mandibular Width (W), Length (L), Upper Distance (UD), Lower Distance (LD), Buccal Distance (BD), and Lingual Distance (LID). The obtained data were evaluated using SPSS software, applying paired t-test and intra-class correlation coefficient (ICC). There was a significant difference between the values obtained by MSCT and CBCT measurement for all areas such as H, W, UD, LD, BD, and LID, (P < 0.001), with a difference less than 1 mm. The ICC for all distances by both techniques, measured by a single observer with a one week interval and between 2 observers was 99% and 98%, respectively. Comparing the obtained data of both techniques indicates that the difference between two techniques is 2.17% relative to MSCT. The results of this study showed that there is significant difference between measurements obtained by CBCT and MSCT. However, the difference is not clinically significant.
Eisner, Brian H; Kambadakone, Avinash; Monga, Manoj; Anderson, James K; Thoreson, Andrew A; Lee, Hang; Dretler, Stephen P; Sahani, Dushyant V
2009-04-01
We determined the most accurate method of measuring urinary stones on computerized tomography. For the in vitro portion of the study 24 calculi, including 12 calcium oxalate monohydrate and 12 uric acid stones, that had been previously collected at our clinic were measured manually with hand calipers as the gold standard measurement. The calculi were then embedded into human kidney-sized potatoes and scanned using 64-slice multidetector computerized tomography. Computerized tomography measurements were performed at 4 window settings, including standard soft tissue windows (window width-320 and window length-50), standard bone windows (window width-1120 and window length-300), 5.13x magnified soft tissue windows and 5.13x magnified bone windows. Maximum stone dimensions were recorded. For the in vivo portion of the study 41 patients with distal ureteral stones who underwent noncontrast computerized tomography and subsequently spontaneously passed the stones were analyzed. All analyzed stones were 100% calcium oxalate monohydrate or mixed, calcium based stones. Stones were prospectively collected at the clinic and the largest diameter was measured with digital calipers as the gold standard. This was compared to computerized tomography measurements using 4.0x magnified soft tissue windows and 4.0x magnified bone windows. Statistical comparisons were performed using Pearson's correlation and paired t test. In the in vitro portion of the study the most accurate measurements were obtained using 5.13x magnified bone windows with a mean 0.13 mm difference from caliper measurement (p = 0.6). Measurements performed in the soft tissue window with and without magnification, and in the bone window without magnification were significantly different from hand caliper measurements (mean difference 1.2, 1.9 and 1.4 mm, p = 0.003, <0.001 and 0.0002, respectively). When comparing measurement errors between stones of different composition in vitro, the error for calcium oxalate calculi was significantly different from the gold standard for all methods except bone window settings with magnification. For uric acid calculi the measurement error was observed only in standard soft tissue window settings. In vivo 4.0x magnified bone windows was superior to 4.0x magnified soft tissue windows in measurement accuracy. Magnified bone window measurements were not statistically different from digital caliper measurements (mean underestimation vs digital caliper 0.3 mm, p = 0.4), while magnified soft tissue windows were statistically distinct (mean underestimation 1.4 mm, p = 0.001). In this study magnified bone windows were the most accurate method of stone measurements in vitro and in vivo. Therefore, we recommend the routine use of magnified bone windows for computerized tomography measurement of stones. In vitro the measurement error in calcium oxalate stones was greater than that in uric acid stones, suggesting that stone composition may be responsible for measurement inaccuracies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martins de Oliveira, Jose Jr.; Germano Martins, Antonio Cesar
X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe a non-conventional application of computerized tomography: visualization and improvements in the understanding of some internal structural features of solid dosage forms. A micro-CT X-ray scanner, with a minimum resolution of 30 mum was used to characterize some pharmaceutical tablets, granules, controlled-release osmotic tablet and liquid-filled soft-gelatin capsules. The analysis presented in this work are essentially qualitative, but quantitative parameters, such as porosity, density distribution, tablets dimensions, etc. could also be obtained using the related CT techniques.
Sahani, Dushyant; Saini, Sanjay; D'Souza, Roy V; O'Neill, Mary Jane; Prasad, Srinivasa R; Kalra, Mannudeep K; Halpern, Elkan F; Mueller, Peter
2003-01-01
The purpose of this study was to compare the performance of low helical pitch acquisition (3:1) and high helical pitch acquisition (6:1) for routine abdominal/pelvic imaging with multislice computed tomography (CT). Three hundred eighty-four patients referred for abdominal/pelvic CT were examined in a breath-hold on a multislice CT scanner (LightSpeed QX/I; General Electric Medical Systems, Milwaukee, WI). Patients were randomized and scanned with pitch of 3:1 or 6:1 using a constant 140 peak kV and 280-300 mA. Images were reconstructed at a 3.75-mm slice thickness. Direct comparison between the two pitches was possible in a subset of 40 patients who had a follow-up scan performed with the second pitch used in each patient. A comparison was also performed between standard dose CT using a pitch of 6:1 and 20% reduced radiation dose CT using a pitch of 3:1. Two readers performed a blind evaluation using a three-point scale for image quality, anatomic details, and motion artifacts. Statistical analysis was performed using a rank sum test and the Wilcoxon signed rank test. Overall image quality mean scores were 2.5 and 2.3 for a pitch of 3:1 and a pitch of 6:1, respectively (P = 0.134). Likewise, mean anatomic detail and motion artifact scores were 2.5 and 2.6 for a 3:1 pitch and 2.3 and 2.5 for a 6:1 pitch, respectively (P > 0.05). In patients with a direct comparison of the two pitches (with the standard radiation dose as well as with a 20% reduction in milliamperes), no statistically significant difference in the performance of the two pitches was observed (P > 0.05). Image quality with a high pitch (6:1) is acceptable for routine abdominal/pelvic CT.
Pathapati, Deepti; Shinkar, Pawan Gulabrao; kumar, Satya Awadhesh; Jha; Dattatreya, Palanki Satya; Chigurupati, Namrata; Chigurupati, Mohana Vamsy; Rao, Vatturi Venkata Satya Prabhakar
2017-01-01
The authors report an interesting coincidental unearthing by 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) of a potentially serious medical condition of emphysematous pyelonephritis in a case of nasopharyngeal carcinoma. The management by conservative ureteric stenting and antibiotics was done with gratifying clinical outcome. PMID:28242985
Allan Cormack, Computerized Axial Tomography (CAT), and Magnetic Resonance
Radiopharmaceuticals, DOE Technical Report, 1977 Emission Computed Tomography: A New Technique for the Quantitative Extending the Power of Nuclear Magnetic Resonance Techniques Magnetic Resonance Imaging Research Top Some
Research on ionospheric tomography based on variable pixel height
NASA Astrophysics Data System (ADS)
Zheng, Dunyong; Li, Peiqing; He, Jie; Hu, Wusheng; Li, Chaokui
2016-05-01
A novel ionospheric tomography technique based on variable pixel height was developed for the tomographic reconstruction of the ionospheric electron density distribution. The method considers the height of each pixel as an unknown variable, which is retrieved during the inversion process together with the electron density values. In contrast to conventional computerized ionospheric tomography (CIT), which parameterizes the model with a fixed pixel height, the variable-pixel-height computerized ionospheric tomography (VHCIT) model applies a disturbance to the height of each pixel. In comparison with conventional CIT models, the VHCIT technique achieved superior results in a numerical simulation. A careful validation of the reliability and superiority of VHCIT was performed. According to the results of the statistical analysis of the average root mean square errors, the proposed model offers an improvement by 15% compared with conventional CIT models.
Gopčević, A; Rode, B; Vučić, M; Horvat, A; Širanović, M; Gavranović, Ž; Košec, V; Košec, A
2017-11-01
Maternal brain death during pregnancy remains an exceedingly complex situation that requires not only a well-considered medical management plan, but also careful decision-making in a legally and ethically delicate situation. Management of brain dead pregnant patients needs to adhere to special strategies that support the mother in a way that she can deliver a viable and healthy child. Brain death in pregnant women is very rare, with only a few published cases. We present a case of a pregnant woman with previously diagnosed multiple brain cavernomas that led to intracranial hemorrhage and brain stem death during the 21st week of pregnancy. The condition that can be proven unequivocally, using tests that do not endanger viability of the fetus, is brain stem death, diagnosed through absence of cranial reflexes. The patient was successfully treated until delivery of a healthy female child at 29weeks of gestation. The patient received continuous hormone substitution therapy, fetal monitoring and extrinsic regulation of maternal homeostasis over 64days. After delivery, the final diagnosis of brain death was established through multi-slice computerized tomography pan-angiography. This challenging case discusses ethical and medical circumstances arising from a diagnosis of maternal brain death, while showing that prolongation of somatic life support in a multidisciplinary setting can result in a successful pregnancy outcome. Copyright © 2017 Elsevier Ltd. All rights reserved.
Rajwani, Adil; Shirazi, Masoumeh G; Disney, Patrick J S; Wong, Dennis T L; Teo, Karen S L; Delacroix, Sinny; Chokka, Ramesh G; Young, Glenn D; Worthley, Stephen G
2015-12-01
Predictors of residual leak following percutaneous LAA closure were evaluated. Left atrial appendage (LAA) closure aims to exclude this structure from the circulation, typically using a circular occluder. A noncircular orifice is frequently encountered however, and fibrous remodeling of the LAA in atrial fibrillation may restrict orifice deformation. Noncircularity may thus be implicated in the occurrence of residual leak despite an appropriately oversized device. Pre-procedural multislice computerized tomography was used to quantify LAA orifice eccentricity and irregularity. Univariate predictors of residual leak were identified with respect to the orifice, device, and relevant clinical variables, with the nature of any correlations then further evaluated. Eccentricity and irregularity indexes of the orifice in 31 individuals were correlated with residual leak even where the device was appropriately oversized. An eccentricity index of 0.15 predicted a residual leak with 85% sensitivity and 59% specificity. An irregularity index of 0.05 predicted a significant residual leak ≥3 mm with 100% sensitivity and 86% specificity. Orifice size, device size, degree of device oversize, left atrial volume, and pulmonary artery pressure were not predictors of residual leak. Eccentricity and irregularity of the LAA orifice are implicated in residual leak after percutaneous closure even where there is appropriate device over-size. Irregularity index in particular is a novel predictor of residual leak, supporting a closer consideration of orifice morphology before closure. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Computerized tomography calibrator
NASA Technical Reports Server (NTRS)
Engel, Herbert P. (Inventor)
1991-01-01
A set of interchangeable pieces comprising a computerized tomography calibrator, and a method of use thereof, permits focusing of a computerized tomographic (CT) system. The interchangeable pieces include a plurality of nestable, generally planar mother rings, adapted for the receipt of planar inserts of predetermined sizes, and of predetermined material densities. The inserts further define openings therein for receipt of plural sub-inserts. All pieces are of known sizes and densities, permitting the assembling of different configurations of materials of known sizes and combinations of densities, for calibration (i.e., focusing) of a computerized tomographic system through variation of operating variables thereof. Rather than serving as a phanton, which is intended to be representative of a particular workpiece to be tested, the set of interchangeable pieces permits simple and easy standardized calibration of a CT system. The calibrator and its related method of use further includes use of air or of particular fluids for filling various openings, as part of a selected configuration of the set of pieces.
Advances in the Study of the Middle Cranial Fossa through Cutting Edge Neuroimaging Techniques.
Juanes Méndez, Juan A; Ruisoto, Pablo; Paniagua, Juan C; Prats, Alberto
2018-01-16
The objective of this paper is to present a morphometric study of the middle cranial fossa from the study of 87 patients using cutting edge multislice computed tomography scans (32 detectors) and Magnetic Resonance Imaging. The study presents a detailed anatomical-radiological and morphometric analysis of the middle cranial fossa as well as its neurovascular elements in normal conditions. The implications of this investigation in training and clinical contexts are discussed.
Muselaers, Constantijn H J; Rijpkema, Mark; Bos, Desirée L; Langenhuijsen, Johan F; Oyen, Wim J G; Mulders, Peter F A; Oosterwijk, Egbert; Boerman, Otto C
2015-08-01
Tumor targeted optical imaging using antibodies labeled with near infrared fluorophores is a sensitive imaging modality that might be used during surgery to assure complete removal of malignant tissue. We evaluated the feasibility of dual modality imaging and image guided surgery with the dual labeled anti-carbonic anhydrase IX antibody preparation (111)In-DTPA-G250-IRDye800CW in mice with intraperitoneal clear cell renal cell carcinoma. BALB/c nu/nu mice with intraperitoneal SK-RC-52 lesions received 10 μg DTPA-G250-IRDye800CW labeled with 15 MBq (111)In or 10 μg of the dual labeled irrelevant control antibody NUH-82 (20 mice each). To evaluate when tumors could be detected, 4 mice per group were imaged weekly during 5 weeks with single photon emission computerized tomography/computerized tomography and the fluorescence imaging followed by ex vivo biodistribution studies. As early as 1 week after tumor cell inoculation single photon emission computerized tomography and fluorescence images showed clear delineation of intraperitoneal clear cell renal cell carcinoma with good concordance between single photon emission computerized tomography/computerized tomography and fluorescence images. The high and specific accumulation of the dual labeled antibody conjugate in tumors was confirmed in the biodistribution studies. Maximum tumor uptake was observed 1 week after inoculation (mean ± SD 58.5% ± 18.7% vs 5.6% ± 2.3% injected dose per gm for DTPA-G250-IRDye800CW vs NUH-82, respectively). High tumor uptake was also observed at other time points. This study demonstrates the feasibility of dual modality imaging with dual labeled antibody (111)In-DTPA-G250-IRDye800CW in a clear cell renal cell carcinoma model. Results indicate that preoperative and intraoperative detection of carbonic anhydrase IX expressing tumors, positive resection margins and metastasis might be feasible with this approach. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Liver metastases: imaging considerations for protocol development with Multislice CT (MSCT)
Silverman, Paul M
2006-01-01
Conventional, single-slice helical computed tomography (SSCT) allowed for scanning the majority of the liver during the critical portal venous phase. This was often referred to as the ‘optimal temporal window’. The introduction of current day multislice CT (MSCT) now allows us to acquire images in a much shorter time and more precisely than ever before. This yields increased conspicuity between low attenuation lesions and the enhanced normal liver parenchyma and optimal imaging for the vast majority of hepatic hypovascular metastases. Most importantly, these scanners, when compared to conventional non-helical scanners, avoid impinging upon the ‘equilibrium’ phase when tumors can become isodense/invisible. MSCT also allows for true multiphase scanning during the arterial and late arterial phases for detection of hypervascular metastases. The MSCT imaging speed has increased significantly over the past years with the introduction of 32- and 64-detector systems and will continue to increase in the future volumetric CT. This provides a number of important gains that are discussed in detail. PMID:17098650
Deetjen, Anja; Möllmann, Susanne; Conradi, Guido; Rolf, Andreas; Schmermund, Axel; Hamm, Christian W; Dill, Thorsten
2007-01-01
Objective To evaluate the radiation‐dose‐reduction potential of automatic exposure control (AEC) in 16‐slice and 64‐slice multislice computed tomography (MSCT) of the coronary arteries (computed tomography angiography, CTA) in patients. The rapid growth in MSCT CTA emphasises the necessity of adjusting technique factors to reduce radiation dose exposure. Design A retrospective data analysis was performed for 154 patients who had undergone MSCT CTA. Group 1 (n = 56) had undergone 16‐slice MSCT without AEC, and group 2 (n = 51), with AEC. In group 1, invasive coronary angiography (ICA) had been performed in addition. Group 3 (n = 47) had been examined using a 64‐slice scanner (with AEC, without ECG‐triggered tube current modulation). Results In group 1, the mean (SD) effective dose (ED) for MSCT CTA was 9.76 (1.84) mSv and for ICA it was 2.6 (1.27) mSv. In group 2, the mean ED for MSCT CTA was 5.83 (1.73) mSv, which signifies a 42.8% dose reduction for CTA by the use of AEC. In comparison to ICA, MSCT CTA without AEC shows a 3.8‐fold increase in radiation dose, and the radiation dose of CTA with AEC was increased by a factor of 1.9. In group 3, the mean ED for MSCT CTA was 13.58 (2.80) mSV. Conclusions This is the first study to show the significant dose‐reduction potential (42.8%) of AEC in MSCT CTA in patients. This relatively new technique can be used to optimise the radiation dose levels in MSCT CTA. PMID:17395667
Cueff, Caroline; Serfaty, Jean-Michel; Cimadevilla, Claire; Laissy, Jean-Pierre; Himbert, Dominique; Tubach, Florence; Duval, Xavier; Iung, Bernard; Enriquez-Sarano, Maurice; Vahanian, Alec; Messika-Zeitoun, David
2011-05-01
Measurement of the degree of aortic valve calcification (AVC) using electron beam computed tomography (EBCT) is an accurate and complementary method to transthoracic echocardiography (TTE) for assessment of the severity of aortic stenosis (AS). Whether threshold values of AVC obtained with EBCT could be extrapolated to multislice computed tomography (MSCT) was unclear and AVC diagnostic value in patients with low ejection fraction (EF) has never been specifically evaluated. Patients with mild to severe AS underwent prospectively within 1 week MSCT and TTE. Severe AS was defined as an aortic valve area (AVA) of less than 1 cm(2). In 179 patients with EF greater than 40% (validation set), the relationship between AVC and AVA was evaluated. The best threshold of AVC for the diagnosis of severe AS was then evaluated in a second subset (testing set) of 49 patients with low EF (≤40%). In this subgroup, AS severity was defined based on mean gradient, natural history or dobutamine stress echocardiography. Correlation between AVC and AVA was good (r=-0.63, p<0.0001). A threshold of 1651 arbitrary units (AU) provided 82% sensitivity, 80% specificity, 88% negative-predictive value and 70% positive-predictive value. In the testing set (patients with low EF), this threshold correctly differentiated patients with severe AS from non-severe AS in all but three cases. These three patients had an AVC score close to the threshold (1206, 1436 and 1797 AU). In this large series of patients with a wide range of AS, AVC was shown to be well correlated to AVA and may be a useful adjunct for the evaluation of AS severity especially in difficult cases such as patients with low EF.
Traversi, Egidio; Bertoli, Giuseppe; Barazzoni, Giancarlo; Baldi, Maurizia; Tramarin, Roberto
2004-02-01
The recent technical developments in multislice computed tomography (MSCT), with ECG retro-gated image reconstruction, have elicited great interest in the possibility of accurate non-invasive imaging of the coronary arteries. The latest generation of MSCT systems with 8-16 rows of detectors permits acquisition of the whole cardiac volume during a single 15-20 s breath-hold with a submillimetric definition of the images and an outstanding signal-to-noise ratio. Thus the race which, between MSCT, electron beam computed tomography and cardiac magnetic resonance imaging, can best provide routine and reliable imaging of the coronary arteries in clinical practice has recommenced. Currently available MSCT systems offer different options for both cardiac image acquisition and reconstruction, including multiplanar and curved multiplanar reconstruction, three-dimensional volume rendering, maximum intensity projection, and virtual angioscopy. In our preliminary experience including 176 patients suffering from known or suspected coronary artery disease, MSCT was feasible in 161 (91.5%) and showed a sensitivity of 80.4% and a specificity of 80.3%, with respect to standard coronary angiography, in detecting critical stenosis in coronary arteries and artery or venous bypass grafts. These results correspond to a positive predictive value of 58.6% and a negative predictive value of 92.2%. The true role that MSCT is likely to play in the future in non-invasive coronary imaging is still to be defined. Nevertheless, the huge amount of data obtainable by MSCT along with the rapid technological advances, shorter acquisition times and reconstruction algorithm developments will make the technique stronger, and possible applications are expected not only for non-invasive coronary angiography, but also for cardiac function and myocardial perfusion evaluation, as an all-in-one examination.
The poppy seed test for colovesical fistula: big bang, little bucks!
Kwon, Eric O; Armenakas, Noel A; Scharf, Stephen C; Panagopoulos, Georgia; Fracchia, John A
2008-04-01
Diagnosis of a colovesical fistula is often challenging, and usually involves numerous invasive and expensive tests and procedures. The poppy seed test stands out as an exception to this rule. We evaluated the accuracy and cost-effectiveness of various established diagnostic tests used to evaluate a suspected colovesical fistula. We identified 20 prospectively entered patients with surgically confirmed colovesical fistulas between 2000 and 2006. Each patient was evaluated preoperatively with a (51)chromium nuclear study, computerized tomography of the abdomen and pelvis with oral and intravenous contrast medium, and the poppy seed test. Costs were calculated using institutional charges, 2006 Medicare limiting approved charges and the market price, respectively. The z test was used to compare the proportion of patients who tested positive for a fistula with each of these modalities. The chromium study was positive in 16 of 20 patients (80%) at a cost of $490.83 per study. Computerized tomography was positive in 14 of 20 patients (70%) at a cost of $652.92 per study. The poppy seed test was positive in 20 of 20 patients (100%) at a cost of $5.37 per study. The difference in the proportion of patients who tested positive for a fistula on computerized tomography and the poppy seed test was statistically significant (p = 0.03). There was no difference between the chromium group and the computerized tomography or poppy seed group (p = 0.72 and 0.12, respectively). The poppy seed test is an accurate, convenient and inexpensive diagnostic test. It is an ideal initial consideration for evaluating a suspected colovesical fistula.
Positron emission tomography/computerized tomography in lung cancer
Vural, Gulin Ucmak
2014-01-01
Positron emission tomography (PET) using 2-(18F)-flouro-2-deoxy-D-glucose (FDG) has emerged as a useful tool in the clinical work-up of lung cancer. This review article provides an overview of applications of PET in diagnosis, staging, treatment response evaluation, radiotherapy planning, recurrence assessment and prognostication of lung cancer. PMID:24914421
The role of preoperative CT scan in patients with tracheoesophageal fistula: a review.
Garge, Saurabh; Rao, K L N; Bawa, Monika
2013-09-01
The morbidity and mortality associated with esophageal atresia with or without a fistula make it a challenging congenital abnormality for the pediatric surgeon. Anatomic factors like inter-pouch gap and origin of fistula are not taken into consideration in various prognostic classifications. The preoperative evaluation of these cases with computerized tomography (CT) has been used by various investigators to delineate these factors. We reviewed these studies to evaluate the usefulness of this investigation in the intra operative and post operative period. A literature search was done on all peer-reviewed articles published on preoperative computed tomography (CT) in cases of tracheoesophageal fistula using the PUBMED and MEDLINE search engines. Key words included tracheoesophageal fistula, computerized tomography, virtual bronchoscopy, and 3D computerized tomography reconstruction. Further, additional articles were selected from the list of references obtained from the retrieved publications. A total of 8 articles were selected for analysis. In most of the studies, comprising 96 patients, observations noted in preoperative CT were confirmed during surgery. In a study by Mahalik et al [Mahalik SK, Sodhi KS, Narasimhan KL, Rao KL. Role of preoperative 3D CT reconstruction for evaluation of patients with esophageal atresia and tracheoesophageal fistula. Pediatr Surg Int. 2012 Jun 22. [Epub ahead of print
[The role of multidetector computer tomography in diagnosis of acute pancreatitis].
Lohanikhina, K Iu; Hordiienko, K P; Kozarenko, T M
2014-10-01
With the objective to improve the diagnostic semiotics of an acute pancreatitis (AP) 35 patients were examined, using 64-cut computeric tomograph Lightspeed VCT (GE, USA) with intravenous augmentation in arterial and portal phases. Basing on analysis of the investigations conducted, using multidetector computeric tomography (MDCT), the AP semiotics was systematized, which is characteristic for oedematous and destructive forms, diagnosed in 19 (44.2%) and 16 (45.8%) patients, accordingly. The procedure for estimation of preservation of the organ functional capacity in pancreonecrosis pres- ence was elaborated, promoting rising of the method diagnostic efficacy by 5.3 - 9.4%.
Ferreira, F J O; Crispim, V R; Silva, A X
2010-06-01
In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials. Copyright 2010 Elsevier Ltd. All rights reserved.
An Analysis of the Need for a Whole-Body CT Scanner at US Darnall Army Community Hospital
1980-05-01
TASK IWORK UNIT ELEMENT NO. I NO.JC NO. rSSION NO. Ij6T’,WAM ’"Aa1W% A WHOLE BODY CT SCANNER AT DARNALL ARMY COMUNITY HOSPITAL 16PTR3OAL tUTHOR(S)* a...computerized axial tomography or CT. Computerized tomography experiments "were conducted by Godfrey Hounsfield at Central Research Laboratories, EMI, Ltd. in...remained the same, with clinical and nursing unit facilities to support a one division post. Presently, Fort Hood is the home of the III US Army Corps, the
NASA Astrophysics Data System (ADS)
Guo, J.; Bücherl, T.; Zou, Y.; Guo, Z.
2011-09-01
Investigations on the fast neutron beam geometry for the NECTAR facility are presented. The results of MCNP simulations and experimental measurements of the beam distributions at NECTAR are compared. Boltzmann functions are used to describe the beam profile in the detection plane assuming the area source to be set up of large number of single neutron point sources. An iterative algebraic reconstruction algorithm is developed, realized and verified by both simulated and measured projection data. The feasibility for improved reconstruction in fast neutron computerized tomography at the NECTAR facility is demonstrated.
Arisan, Volkan; Karabuda, Zihni Cüneyt; Pişkin, Bülent; Özdemir, Tayfun
2013-12-01
Deviations of implants that were placed by conventional computed tomography (CT)- or cone beam CT (CBCT)-derived mucosa-supported stereolithographic (SLA) surgical guides were analyzed in this study. Eleven patients were randomly scanned by a multi-slice CT (CT group) or a CBCT scanner (CBCT group). A total of 108 implants were planned on the software and placed using SLA guides. A new CT or CBCT scan was obtained and merged with the planning data to identify the deviations between the planned and placed implants. Results were analyzed by Mann-Whitney U test and multiple regressions (p < .05). Mean angular and linear deviations in the CT group were 3.30° (SD 0.36), and 0.75 (SD 0.32) and 0.80 mm (SD 0.35) at the implant shoulder and tip, respectively. In the CBCT group, mean angular and linear deviations were 3.47° (SD 0.37), and 0.81 (SD 0.32) and 0.87 mm (SD 0.32) at the implant shoulder and tip, respectively. No statistically significant differences were detected between the CT and CBCT groups (p = .169 and p = .551, p = .113 for angular and linear deviations, respectively). Implant placement via CT- or CBCT-derived mucosa-supported SLA guides yielded similar deviation values. Results should be confirmed on alternative CBCT scanners. © 2012 Wiley Periodicals, Inc.
van Werkhoven, J M; Gaemperli, O; Schuijf, J D; Jukema, J W; Kroft, L J; Leschka, S; Alkadhi, H; Valenta, I; Pundziute, G; de Roos, A; van der Wall, E E; Kaufmann, P A; Bax, J J
2009-10-01
To assess whether multislice computed tomography coronary angiography (MSCTA) may be useful for risk stratification of patients with suspected coronary artery disease (CAD) at intermediate pretest likelihood according to Diamond and Forrester. MSCTA images were evaluated for the presence of significant CAD in 316 patients with suspected CAD (60% male, average (SD) age 57 (11) years) and an intermediate pretest likelihood according to Diamond and Forrester. Patients were followed up to determine the occurrence of an event. A combined end point of all-cause mortality, non-fatal infarction and unstable angina requiring revascularisation. Significant CAD was seen in 89 patients (28%), whereas normal MSCTA or non-significant CAD was seen in the remaining 227 (72%) patients. During follow-up (median 621 days (25-75th centile 408-835) an event occurred in 13 patients (4.8%). The annualised event rate was 0.8% in patients with normal MSCT, 2.2% in patients with non-significant CAD and 6.5% in patients with significant CAD. Moreover, MSCTA remained a significant predictor (p<0.05) of events after multivariate correction (hazard ratio = 3.460 (95% CI 1.142 to 10.480). The results suggest that in patients with an intermediate pretest likelihood, MSCTA is highly effective in re-stratifying patients into either a low or high post-test risk group. These results further emphasise the usefulness of non-invasive imaging with MSCTA in this patient population.
Ionospheric tomography using ADS-B signals
NASA Astrophysics Data System (ADS)
Cushley, A. C.; Noël, J.-M.
2014-07-01
Numerical modeling has demonstrated that Automatic Dependent Surveillance Broadcast (ADS-B) signals can be used to reconstruct two-dimensional (2-D) electron density maps of the ionosphere using techniques for computerized tomography. Ray tracing techniques were used to determine the characteristics of individual waves, including the wave path and the state of polarization at the satellite receiver. The modeled Faraday rotation was computed and converted to total electron content (TEC) along the raypaths. The resulting TEC was used as input for computerized ionospheric tomography (CIT) using algebraic reconstruction technique. This study concentrated on reconstructing mesoscale structures 25-100 km in horizontal extent. The primary scientific interest of this study was to show that ADS-B signals can be used as a new source of data for CIT to image the ionosphere and to obtain a better understanding of magneto-ionic wave propagation.
Technological Advances in the Study of Reading: An Introduction.
ERIC Educational Resources Information Center
Henk, William A.
1991-01-01
Describes the purpose and functional operation of new computer-driven technologies such as computerized axial tomography, positron emissions transaxial tomography, regional cerebral blood flow monitoring, magnetic resonance imaging, and brain electrical activity mapping. Outlines their current contribution to the knowledge base. Speculates on the…
Emission computerized axial tomography from multiple gamma-camera views using frequency filtering.
Pelletier, J L; Milan, C; Touzery, C; Coitoux, P; Gailliard, P; Budinger, T F
1980-01-01
Emission computerized axial tomography is achievable in any nuclear medicine department from multiple gamma camera views. Data are collected by rotating the patient in front of the camera. A simple fast algorithm is implemented, known as the convolution technique: first the projection data are Fourier transformed and then an original filter designed for optimizing resolution and noise suppression is applied; finally the inverse transform of the latter operation is back-projected. This program, which can also take into account the attenuation for single photon events, was executed with good results on phantoms and patients. We think that it can be easily implemented for specific diagnostic problems.
Karlicic, Vukoica; Vukovic, Jelena; Stanojevic, Ivan; Sotirovic, Jelena; Peric, Aleksandar; Jovic, Milena; Cvijanovic, Vlado; Djukic, Mirjana; Banovic, Tatjana; Vojvodic, Danilo
2016-01-01
Advanced lung carcinoma is charasterized with fast disease progression. Interleukin (IL)10 and transforming growth factor (TGF)b1 are immunosuppressive mediators and their role in lung carcinoma pathogenesis and in the antitumor response has not yet been elucidated. The purpose of this study was to correlate IL10 and TGFb1 levels in the serum and lung tumor microcirculation with clinical stage, disease extent, histological features and TNM stage. The study included 41 lung cancer patients in clinical stage III and IV. Histological type was determined immunohistochemically, while tumor size, localization and dissemination were determined radiologically by multislice computerized tomography (MSCT). IL10 and TGFb1 levels were quantified with commercial flow cytometric test in serum and lung tumor microcirculation samples. Non small cell lung cancer (NSCLC) patients had significantly elevated TGFb1 while small cell lung cancer (SCLC) patients had significantly increased IL10 in tumor microcirculation. IL10 was significantly elevated in patients with the largest tumors, as well as in patients with III clinical stage and without metastases, both in the serum and tumor microcirculation. TGFb1 was significantly increased in serum and tumor microcirculation in patients with larger tumors. We found significant correlation between these two immunosuppressive cytokines, IL10 and TGFb1, in tumor microcirculation but not in patient serum samples. IL10 and TGFb1 in systemic and tumor microcirculation are significantly associated with particular histological type of lung cancer, tumor size and degree of disease extent.
Decapitation in reality and fine art: A review.
Nikolić, Valentina; Savić, Slobodan; Antunović, Vaso; Marinković, Slobodan; Andrieux, Charlotte; Tomić, Irina
2017-11-01
The aim of our study was to examine all types of decapitation from forensic literature, including our own case, and to analyze the presentation of beheading in fine art, popular literature, and music. To do this, over 200 scientific articles in regard to decapitation were analyzed, as well as more than 10,000 artworks, and several hundreds of literary works and music pieces. In addition, a macroscopic examination of a decapitated victim was performed. Finally, a multislice computerized tomography (MSCT) examination of the cervical spine in two live volunteers was undertaken to present the osteological relationships. The forensic and criminal investigation revealed that a female victim was murdered by her jealous husband by applying several strikes with an axe, which resulted in an incomplete decapitation. All the main neck structures were transected, including the cervical spine, except a smaller part of the skin and soft tissue in the nuchal region. The mentioned MSCT examination in both the neutral position and flexion showed that the mandible can also be injured in a higher cervical location of the severance line. Various types of beheading were mentioned, including a homicidal, suicidal, accidental, judicial, internal, pathophysiological, and foetal ones. The status of consciousness and emotions in individuals just before and after decapitation was discussed. Finally, it was found that decapitation was the subject of many artists, and some writers and musicians. In conclusion, we presented a rare case of a homicide beheading performed with an axe. In addition, forensic importance of decapitation was discussed, as well as its great medical, social, anthropological, and artistic significance. Copyright © 2017 Elsevier B.V. All rights reserved.
Cho, Jae-Hoon; Cho, Dae-Chul; Sung, Joo-Kyung
2012-01-01
We report the case of a 47-year-old man who presented with progressive paraparesis and sphincter changes over 2 weeks. Magnetic resonance imaging revealed a spinal epidural mass from T9 to L2. We performed a decompressive laminectomy and mass removal. The histopathology was consistent with a small lymphocytic lymphoma. No metastatic lesion was noted in the chest and abdomen-pelvic computerized tomography (CT) and positron emission tomography computerized tomography (PET-CT) scan. The final diagnosis was primary spinal lymphoma, so we performed chemotherapy combined with radiotherapy. At one year follow-up, he had no neurological deficit and no recurrence on neurologic and radiologic exams. Primary spinal cord lymphomas should be considered in the differential diagnosis of spinal cord tumors. Early surgical management is mandatory to achieve a recovery of neurologic function, especially if the patient has a neurological deficit. PMID:25983828
Congenital Anomaly of Single Dominant Right Coronary Artery with Hypoplastic Left Coronary Artery.
Chuang, Cheng-Yen; Chen, Yen-Chou; Cheng, Ho-Shun; Hsieh, Ming-Hsiung
2015-11-01
With the popularization of new imaging technology, more people are deciding to undergo non-invasive studies such as multidetector computerized tomography (MDCT) before receiving coronary angiography. For this reason, coronary anomalies of coronary artery are being encountered more frequently. We here report a 68-year-old male presenting with typical angina. The MDCT images suggested chronic total occlusion of the left anterior descending (LAD) artery with collateral circulation from the right coronary artery (RCA). The patient's coronary angiography showed a congenital coronary anomaly with a single dominant RCA supplying the entire coronary circulation of the heart with both LAD and left circumflex artery hypoplasia. Angiography; Anomaly; Computerized tomography; Coronary artery.
NASA Astrophysics Data System (ADS)
Strocchi, Sabina; Colli, Vittoria; Novario, Raffaele; Carrafiello, Gianpaolo; Giorgianni, Andrea; Macchi, Aldo; Fugazzola, Carlo; Conte, Leopoldo
2007-03-01
Aim of this work is to compare the performances of a Xoran Technologies i-CAT Cone Beam CT for dental applications with those of a standard total body multislice CT (Toshiba Aquilion 64 multislice) used for dental examinations. Image quality and doses to patients have been compared for the three main i-CAT protocols, the Toshiba standard protocol and a Toshiba modified protocol. Images of two phantoms have been acquired: a standard CT quality control phantom and an Alderson Rando ® anthropomorphic phantom. Image noise, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR) and geometric accuracy have been considered. Clinical image quality was assessed. Effective dose and doses to main head and neck organs were evaluated by means of thermo-luminescent dosimeters (TLD-100) placed in the anthropomorphic phantom. A Quality Index (QI), defined as the ratio of squared CNR to effective dose, has been evaluated. The evaluated effective doses range from 0.06 mSv (i-CAT 10 s protocol) to 2.37 mSv (Toshiba standard protocol). The Toshiba modified protocol (halved tube current, higher pitch value) imparts lower effective dose (0.99 mSv). The conventional CT device provides lower image noise and better SNR, but clinical effectiveness similar to that of dedicated dental CT (comparable CNR and clinical judgment). Consequently, QI values are much higher for this second CT scanner. No geometric distortion has been observed with both devices. As a conclusion, dental volumetric CT supplies adequate image quality to clinical purposes, at doses that are really lower than those imparted by a conventional CT device.
[The importance of neurological examinations in the age of the technological revolution].
Berbel-García, A; González-Spínola, J; Martínez-Salio, A; Porta-Etessam, J; Pérez-Martínez, D A; de Toledo, M; Sáiz-Díaz, R A
Neurologic practice and care have been modified in many important ways during the past ten years, to adapt to the explosion of new information and new technology. Students, residents and practicing physicians have been continuing programs to a model that focuses almost exclusively on the applications to neurologic disorders of the new knowledge obtained from biomedical research. On the other hand high demand for outpatient neurologic care prevents adequate patient's evaluation. Case 1: 65 years old female. Occipital headache diagnosed of tensional origin (normal computerized tomography). Two months later is re-evaluated due to intractable pain and hypoglossal lesion. An amplified computerized tomography revealed a occipital condyle metastasis. Case 2: 21 years old female. Clinical suspicion of demyelinating disease due to repeated facial paresis and sensitive disorder. General exploration and computerized tomography revealed temporo-mandibular joint. Case 3: 60 years old female. Valuation of anticoagulant therapy due to repeated transient ischemic attacks. She suffered from peripheral facial palsy related to auditory cholesteatoma. Neurologic education is nowadays orientated to new technologies. On the other hand, excessive demand prevents adequate valuation and a minute exploration is substituted by complementary evaluations. These situations generate diagnostic mistakes or iatrogenic. It would be important a consideration of the neurologic education profiles and fulfillment of consultations time recommendations for outpatients care.
Maeda, Koichi; Kuratani, Toru; Torikai, Kei; Shimamura, Kazuo; Mizote, Isamu; Ichibori, Yasuhiro; Takeda, Yasuharu; Daimon, Takashi; Nakatani, Satoshi; Nanto, Shinsuke; Sawa, Yoshiki
2013-07-01
Even mild paravalvular leakage (PVL) after transcatheter aortic valve replacement (TAVR) is associated with increased late mortality. Electrocardiogram-gated multi-slice computed tomography (MSCT) enables detailed aortic annulus assessment. We describe the impact of MSCT for PVL following TAVR. Congruence between the prosthesis and annulus diameters affects PVL; therefore, we calculated the OverSized AortiC Annular ratio (OSACA ratio) and OSACA (transesophageal echocardiography, TEE) ratio as prosthesis diameter/annulus diameter on MSCT or TEE, respectively, and compared their relationship with PVL ≤ trace following TAVR. Of 36 consecutive patients undergoing TAVR (Group A), the occurrence of PVL ≤ trace (33.3%) was significantly related to the OSACA ratio (p = 0.00020). In receiver-operating characteristics analysis, the cutoff value of 1.03 for the OSACA ratio had the highest sum of sensitivity (75.0%) and specificity (91.7%; AUC = 0.87) with significantly higher discriminatory performance for PVL as compared to the OSACA (TEE) ratio (AUC = 0.69, p = 0.028). In nine consecutive patients (Group B) undergoing TAVR based on guidelines formulated from our experience with Group A, PVL ≤ trace was significantly more frequent (88.9%) than that in Group A (p = 0.0060). The OSACA ratio has a significantly higher discriminatory performance for PVL ≤ trace than the OSACA (TEE) ratio, and aortic annular measurement from MSCT is more accurate than that from TEE. © 2013 Wiley Periodicals, Inc.
Efe, Duran; Aygün, Fatih; Acar, Türker; Yildiz, Melda; Gemici, Kazım
2015-08-01
The present study investigated effect of subcutaneous fat volume and abdominal visceral fat volume on aortic atherosclerosis via multislice computed tomography. The present study comprised 424 subjects who underwent non-contrast-enhanced abdominal CT in our clinic between June 2012 and June 2013. Using dedicated software visceral fat volume was calculated for each individual and then subcutaneous fat volume was calculated by subtracting visceral fat volume from total fat volume. By dividing visceral fat volume/subcutaneous fat volume participants were assigned to three groups according to their mean visceral fat volume/subcutaneous fat volume: Group 1 consisted of subjects with visceral fat volume/subcutaneous fat volume lower than 0.48 (Group 1 < 0.48); Group 2 consisted of subjects with visceral fat volume/subcutaneous fat volume equal to or higher than 0.48 and lower than 0.69 (0.48 ≤ Group 2 < 0.69); and Group 3 consisted of subjects with visceral fat volume/subcutaneous fat volume equal to or higher than 0.69 (Group 3 ≥ 0.69). The mean abdominal aortic calcium scores according to Agatston scoring (au) were 136.8 ± 418.7 au in Group 1, 179.9 ± 463 au in Group 2 and 212.2 ± 486.9 in Group 3, respectively. We have demonstrated a significant correlation between visceral fat volume and abdominal aorta atherosclerosis, while there was absence of significant correlation between subcutaneous fat volume and abdominal atherosclerosis. © The Author(s) 2014.
von Kiedrowski, Helge; Wiemer, Marcus; Franzke, Krista; Preuss, Rainer; Vaske, Bernhard; Butz, Thomas; Oldenburg, Olaf; Bitter, Thomas; Mahmood, Khalid; Burchert, Wolfram; Horstkotte, Dieter; Langer, Christoph
2009-02-01
Contrast enhanced multi-slice computed tomography (MSCT) is the leading modality in non-invasive coronary angiography (CTA) today. We investigated MSCT based assessment of coronary artery bypass grafts (CABG) by analyzing assets and drawbacks of CTA in order to define demands on latest technology. In a clinical setting 39 CABG patients (69.2 +/- 1.4 years; male n = 36) underwent CTA (collimation 16 x 0.75 mm, contrast medium 100 ml; 320 mAs, 120 KV). Ninety-seven CABG (61 venous, 36 arterial grafts) were evaluated. A subgroup of 18 patients underwent additional invasive coronary angiography (CA). CTA for CABG assessment resulted in an overall sensitivity (sens.) of 100%, specificity (spec.) of 92.4% and positive and negative predictive values (PPV, NPV) of 60% and 100%, respectively. CABG anastomoses showed slightly inferior diagnostic accuracy than other CABG segments. Limitations in imaging quality caused 21% unevaluable segments of the CABG anastomoses. Evaluation of native vessel segments proximal and distal to the anastomoses resulted in a sens, spec, PPV and NPV of 57.5, 94.6, 92 and 67.3%, respectively. With 28.5% unevaluable segments, the native vessel segments showed serious limitations in imaging quality. Radiation exposure was 9.88 +/- 3.20 mSv (9.69 +/- 3.25 mSv male; 12.08 +/- 1.35 mSv female). 16-slice MSCT based CABG assessment offers sufficient diagnostic accuracy. However, focussing on the bypass anastomoses and the native revascularized coronary arteries, clinical value is limited.
NASA Astrophysics Data System (ADS)
Stock, Michala K.; Stull, Kyra E.; Garvin, Heather M.; Klales, Alexandra R.
2016-10-01
Forensic anthropologists are routinely asked to estimate a biological profile (i.e., age, sex, ancestry and stature) from a set of unidentified remains. In contrast to the abundance of collections and techniques associated with adult skeletons, there is a paucity of modern, documented subadult skeletal material, which limits the creation and validation of appropriate forensic standards. Many are forced to use antiquated methods derived from small sample sizes, which given documented secular changes in the growth and development of children, are not appropriate for application in the medico-legal setting. Therefore, the aim of this project is to use multi-slice computed tomography (MSCT) data from a large, diverse sample of modern subadults to develop new methods to estimate subadult age and sex for practical forensic applications. The research sample will consist of over 1,500 full-body MSCT scans of modern subadult individuals (aged birth to 20 years) obtained from two U.S. medical examiner's offices. Statistical analysis of epiphyseal union scores, long bone osteometrics, and os coxae landmark data will be used to develop modern subadult age and sex estimation standards. This project will result in a database of information gathered from the MSCT scans, as well as the creation of modern, statistically rigorous standards for skeletal age and sex estimation in subadults. Furthermore, the research and methods developed in this project will be applicable to dry bone specimens, MSCT scans, and radiographic images, thus providing both tools and continued access to data for forensic practitioners in a variety of settings.
Guddat, Saskia S; Gapert, René; Tsokos, Michael; Oesterhelweg, Lars
2013-03-01
Proof of live birth is of major importance in suspected neonaticide cases. Although not without controversy the lung flotation test is the main method used to asses this in different jurisdictions worldwide. The present study examines the usefulness of postmortem multislice computed tomography (pmMSCT) in the detection of live birth signs. Body scans were conducted on four infants, one was stillborn, another died a day after birth and the other two were classified as neonaticides. The appearance of the lungs, gastrointestinal tract and vascular system of the liver was compared in these cases. Clear differences were discernable between the lungs of the stillborn and the 1 day old infant. The aerated lungs and air in the stomach and duodenum were clearly visible in the latter case while the stillborn infant lacked these signs. The two neonaticide cases demonstrated similarly aerated lung tissue to the 1 day old infant. The hepatic vessels did not show any putrefactive gas changes in any of the cases. The extent of aeration of the peripheral alveoli was easily observable on the pmMSCT, thus making it a useful tool in the possible differentiation between artificially and naturally aerated lungs. During the four autopsies the classic flotation tests were performed and similar positive aeration of the lungs in the two neonaticides was shown. The stillborn's tests, on the other hand were negative for aeration. The results of this study clearly demonstrate the advantages of using pmMSCT before commencing a conventional autopsy in cases of suspected neonaticide.
FFT multislice method--the silver anniversary.
Ishizuka, Kazuo
2004-02-01
The first paper on the FFT multislice method was published in 1977, a quarter of a century ago. The formula was extended in 1982 to include a large tilt of an incident beam relative to the specimen surface. Since then, with advances of computing power, the FFT multislice method has been successfully applied to coherent CBED and HAADF-STEM simulations. However, because the multislice formula is built on some physical approximations and approximations in numerical procedure, there seem to be controversial conclusions in the literature on the multislice method. In this report, the physical implication of the multislice method is reviewed based on the formula for the tilted illumination. Then, some results on the coherent CBED and the HAADF-STEM simulations are presented.
Motion Estimation and Compensation Strategies in Dynamic Computerized Tomography
NASA Astrophysics Data System (ADS)
Hahn, Bernadette N.
2017-12-01
A main challenge in computerized tomography consists in imaging moving objects. Temporal changes during the measuring process lead to inconsistent data sets, and applying standard reconstruction techniques causes motion artefacts which can severely impose a reliable diagnostics. Therefore, novel reconstruction techniques are required which compensate for the dynamic behavior. This article builds on recent results from a microlocal analysis of the dynamic setting, which enable us to formulate efficient analytic motion compensation algorithms for contour extraction. Since these methods require information about the dynamic behavior, we further introduce a motion estimation approach which determines parameters of affine and certain non-affine deformations directly from measured motion-corrupted Radon-data. Our methods are illustrated with numerical examples for both types of motion.
Larrieu, A J; Puglia, E; Allen, P
1982-08-01
The case of a patient who survived strut fracture and embolization of a Björk-Shiley mitral prosthetic disc is presented. Prompt surgical treatment was directly responsible for survival. In addition, computerized axial tomography of the abdomen aided in localizing and retrieving the embolized disc, which was lodged at the origin of the superior mesenteric artery. A review of similar case reports from the literature supports our conclusions that the development of acute heart failure and absent or muffled prosthetic heart sounds in a patient with a Björk-Shiley prosthetic heart valve inserted prior to 1978 should raise the possibility of valve dysfunction and lead to early reoperation.
Diagnostic Imaging of the Hepatobiliary System: An Update.
Marolf, Angela J
2017-05-01
Recent advances in diagnostic imaging of the hepatobiliary system include MRI, computed tomography (CT), contrast-enhanced ultrasound, and ultrasound elastography. With the advent of multislice CT scanners, sedated examinations in veterinary patients are feasible, increasing the utility of this imaging modality. CT and MRI provide additional information for dogs and cats with hepatobiliary diseases due to lack of superimposition of structures, operator dependence, and through intravenous contrast administration. Advanced ultrasound methods can offer complementary information to standard ultrasound imaging. These newer imaging modalities assist clinicians by aiding diagnosis, prognostication, and surgical planning. Copyright © 2016 Elsevier Inc. All rights reserved.
Giant floating thrombus localized in the ascending aorta.
Akyildiz, Mahmut; Zorman, Yilmaz; Aksoy, Tamer; Yilmazer, Mustafa S; Erturk, Esra; Onar, Cagatay L; Midi, Ahmet
2010-06-01
We report the case of a 32-year-old male patient with symptoms of cerebrovascular accident manifesting with dysarthria. A transesophageal echocardiogram showed a floating mass localized in the ascending aorta, and a multislice computed tomography evaluation confirmed the diagnosis. With a comprehensive assessment of the mass, we decided on surgical intervention. A pedunculated and fragile mass was seen just near the right coronary ostium. The measured dimensions were 7.7 x 1.0 x 1.5 cm. The removed mass has been analyzed histopathologically and found to be the cause of the neurologic findings with an uncertain underlying etiology.
Kircelli, Fatih; Asci, Gulay; Carrero, Juan Jesus; Gungor, Ozkan; Demirci, Meltem Sezis; Ozbek, Suha Sureyya; Ceylan, Naim; Ozkahya, Mehmet; Toz, Huseyin; Ok, Ercan
2011-01-01
Summary Background and objectives End-stage renal disease is linked to alterations in thyroid hormone levels and/or metabolism, resulting in a high prevalence of subclinical hypothyroidism and low triiodothyronine (T3) levels. These alterations are involved in endothelial damage, cardiac abnormalities, and inflammation, but the exact mechanisms are unclear. In this study, we investigated the relationship between serum free-T3 (fT3) and carotid artery atherosclerosis, arterial stiffness, and vascular calcification in prevalent patients on conventional hemodialysis. Design, setting, participants, & measurements 137 patients were included. Thyroid-hormone levels were determined by chemiluminescent immunoassay, carotid artery–intima media thickness (CA-IMT) by Doppler ultrasonography, carotid-femoral pulse wave velocity (c-f PWV), and augmentation index by Sphygmocor device, and coronary artery calcification (CAC) scores by multi-slice computerized tomography. Results Mean fT3 level was 3.70 ± 1.23 pmol/L. Across decreasing fT3 tertiles, c-f PWV and CA-IMT values were incrementally higher, whereas CACs were not different. In adjusted ordinal logistic regression analysis, fT3 level (odds ratio, 0.81; 95% confidence interval, 0.68 to 0.97), age, and interdialytic weight gain were significantly associated with CA-IMT. fT3 level was associated with c-f PWV in nondiabetics but not in diabetics. In nondiabetics (n = 113), c-f PWV was positively associated with age and systolic BP but negatively with fT3 levels (odds ratio = 0.57, 95% confidence interval 0.39 to 0.83). Conclusions fT3 levels are inversely associated with carotid atherosclerosis but not with CAC in hemodialysis patients. Also, fT3 levels are inversely associated with surrogates of arterial stiffness in nondiabetics. PMID:21836150
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona
2004-01-15
Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, themore » DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography.« less
NASA Astrophysics Data System (ADS)
Zagorchev, Lyubomir; Manzke, Robert; Cury, Ricardo; Reddy, Vivek Y.; Chan, Raymond C.
2007-03-01
Interventional cardiac electrophysiology (EP) procedures are typically performed under X-ray fluoroscopy for visualizing catheters and EP devices relative to other highly-attenuating structures such as the thoracic spine and ribs. These projections do not however contain information about soft-tissue anatomy and there is a recognized need for fusion of conventional fluoroscopy with pre-operatively acquired cardiac multislice computed tomography (MSCT) volumes. Rapid 2D-3D integration in this application would allow for real-time visualization of all catheters present within the thorax in relation to the cardiovascular anatomy visible in MSCT. We present a method for rapid fusion of 2D X-ray fluoroscopy with 3DMSCT that can facilitate EP mapping and interventional procedures by reducing the need for intra-operative contrast injections to visualize heart chambers and specialized systems to track catheters within the cardiovascular anatomy. We use hardware-accelerated ray-casting to compute digitally reconstructed radiographs (DRRs) from the MSCT volume and iteratively optimize the rigid-body pose of the volumetric data to maximize the similarity between the MSCT-derived DRR and the intra-operative X-ray projection data.
Young, Michael C; Theis, Jake R; Hodges, James S; Dunn, Ty B; Pruett, Timothy L; Chinnakotla, Srinath; Walker, Sidney P; Freeman, Martin L; Trikudanathan, Guru; Arain, Mustafa; Robertson, Paul R; Wilhelm, Joshua J; Schwarzenberg, Sarah J; Bland, Barbara; Beilman, Gregory J; Bellin, Melena D
2016-08-01
Approximately two thirds of patients will remain on insulin therapy after total pancreatectomy with islet autotransplant (TPIAT) for chronic pancreatitis. We investigated the relationship between measured pancreas volume on computerized tomography or magnetic resonance imaging and features of chronic pancreatitis on imaging, with subsequent islet isolation and diabetes outcomes. Computerized tomography or magnetic resonance imaging was reviewed for pancreas volume (Vitrea software) and presence or absence of calcifications, atrophy, and dilated pancreatic duct in 97 patients undergoing TPIAT. Relationship between these features and (1) islet mass isolated and (2) diabetes status at 1-year post-TPIAT were evaluated. Pancreas volume correlated with islet mass measured as total islet equivalents (r = 0.50, P < 0.0001). Mean islet equivalents were reduced by more than half if any one of calcifications, atrophy, or ductal dilatation were observed. Pancreatic calcifications increased the odds of insulin dependence 4.0 fold (1.1, 15). Collectively, the pancreas volume and 3 imaging features strongly associated with 1-year insulin use (P = 0.07), islet graft failure (P = 0.003), hemoglobin A1c (P = 0.0004), fasting glucose (P = 0.027), and fasting C-peptide level (P = 0.008). Measures of pancreatic parenchymal destruction on imaging, including smaller pancreas volume and calcifications, associate strongly with impaired islet mass and 1-year diabetes outcomes.
Fang, Luo; Jingjing, Lu; Ying, Shen; Lan, Meng; Tao, Wang; Nan, Ji
2016-02-01
Sphenopalatine ganglion percutaneous radiofrequency thermocoagulation treatment can improve the symptoms of cluster headaches to some extent. However, as an ablation treatment, radiofrequency thermocoagulation treatment also has side effects. To preliminarily evaluate the efficacy and safety of a non-ablative computerized tomography-guided pulsed radiofrequency treatment of sphenopalatine ganglion in patients with refractory cluster headaches. We included and analysed 16 consecutive cluster headache patients who failed to respond to conservative therapy from the Pain Management Center at the Beijing Tiantan Hospital between April 2012 and September 2013 treated with pulsed radiofrequency treatment of sphenopalatine ganglion. Eleven of 13 episodic cluster headaches patients and one of three chronic cluster headaches patient were completely relieved of the headache within an average of 6.3 ± 6.0 days following the treatment. Two episodic cluster headache patients and two chronic cluster headache patients showed no pain relief following the treatment. The mean follow-up time was 17.0 ± 5.5 months. All patients enrolled in this study showed no treatment-related side effects or complications. Our data show that patients with refractory episodic cluster headaches were quickly, effectively and safely relieved from the cluster period after computerized tomography-guided pulsed radiofrequency treatment of sphenopalatine ganglion, suggesting that it may be a therapeutic option if conservative treatments fail. © International Headache Society 2015.
Identifying and classifying hyperostosis frontalis interna via computerized tomography.
May, Hila; Peled, Nathan; Dar, Gali; Hay, Ori; Abbas, Janan; Masharawi, Youssef; Hershkovitz, Israel
2010-12-01
The aim of this study was to recognize the radiological characteristics of hyperostosis frontalis interna (HFI) and to establish a valid and reliable method for its identification and classification. A reliability test was carried out on 27 individuals who had undergone a head computerized tomography (CT) scan. Intra-observer reliability was obtained by examining the images three times, by the same researcher, with a 2-week interval between each sample ranking. The inter-observer test was performed by three independent researchers. A validity test was carried out using two methods for identifying and classifying HFI: 46 cadaver skullcaps were ranked twice via computerized tomography scans and then by direct observation. Reliability and validity were calculated using Kappa test (SPSS 15.0). Reliability tests of ranking HFI via CT scans demonstrated good results (K > 0.7). As for validity, a very good consensus was obtained between the CT and direct observation, when moderate and advanced types of HFI were present (K = 0.82). The suggested classification method for HFI, using CT, demonstrated a sensitivity of 84%, specificity of 90.5%, and positive predictive value of 91.3%. In conclusion, volume rendering is a reliable and valid tool for identifying HFI. The suggested three-scale classification is most suitable for radiological diagnosis of the phenomena. Considering the increasing awareness of HFI as an early indicator of a developing malady, this study may assist radiologists in identifying and classifying the phenomena.
Konecki, Dariusz; Grabowska-Derlatka, Laretta; Pacho, Ryszard; Rowiński, Olgierd
2017-01-01
Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding.
Bricault, Ivan; Ferretti, Gilbert
2005-01-01
While multislice spiral computed tomography (CT) scanners are provided by all major manufacturers, their specific interpolation algorithms have been rarely evaluated. Because the results published so far relate to distinct particular cases and differ significantly, there are contradictory recommendations about the choice of pitch in clinical practice. In this paper, we present a new tool for the evaluation of multislice spiral CT z-interpolation algorithms, and apply it to the four-slice case. Our software is based on the computation of a "Weighted Radiation Profile" (WRP), and compares WRP to an expected ideal profile in terms of widening and heterogeneity. It provides a unique scheme for analyzing a large variety of spiral CT acquisition procedures. Freely chosen parameters include: number of detector rows, detector collimation, nominal slice width, helical pitch, and interpolation algorithm with any filter shape and width. Moreover, it is possible to study any longitudinal and off-isocenter positions. Theoretical and experimental results show that WRP, more than Slice Sensitivity Profile (SSP), provides a comprehensive characterization of interpolation algorithms. WRP analysis demonstrates that commonly "preferred helical pitches" are actually nonoptimal regarding the formerly distinguished z-sampling gap reduction criterion. It is also shown that "narrow filter" interpolation algorithms do not enable a general preferred pitch discussion, since they present poor properties with large longitudinal and off-center variations. In the more stable case of "wide filter" interpolation algorithms, SSP width or WRP widening are shown to be almost constant. Therefore, optimal properties should no longer be sought in terms of these criteria. On the contrary, WRP heterogeneity is related to variable artifact phenomena and can pertinently characterize optimal pitches. In particular, the exemplary interpolation properties of pitch = 1 "wide filter" mode are demonstrated.
Computerized tomography in neuro-ophthalmology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moseley, I.F.; Sanders, M.D.
This highly specialized text is organized into sections that cover anatomy, diseases of the orbit, visual loss, optic nerve disease, disorders of eye movement, and heredofamilial, developmental, and metabolic disorders.
Computerized PET/CT image analysis in the evaluation of tumour response to therapy
Wang, J; Zhang, H H
2015-01-01
Current cancer therapy strategy is mostly population based, however, there are large differences in tumour response among patients. It is therefore important for treating physicians to know individual tumour response. In recent years, many studies proposed the use of computerized positron emission tomography/CT image analysis in the evaluation of tumour response. Results showed that computerized analysis overcame some major limitations of current qualitative and semiquantitative analysis and led to improved accuracy. In this review, we summarize these studies in four steps of the analysis: image registration, tumour segmentation, image feature extraction and response evaluation. Future works are proposed and challenges described. PMID:25723599
Mochizuki, Yumi; Omura, Ken; Nakamura, Shin; Harada, Hiroyuki; Shibuya, Hitoshi; Kurabayashi, Toru
2012-02-01
This study aimed to construct a preoperative predictive model of cervical lymph node metastasis using fluorine-18 fluorodeoxyglucose positron-emission tomography/computerized tomography ((18)F-FDG PET/CT) findings in patients with oral or oropharyngeal squamous cell carcinoma (SCC). Forty-nine such patients undergoing preoperative (18)F-FDG PET/CT and neck dissection or lymph node biopsy were enrolled. Retrospective comparisons with spatial correlation between PET/CT and the anatomical sites based on histopathological examinations of surgical specimens were performed. We calculated a logistic regression model, including the SUVmax-related variable. When using the optimal cutoff point criterion of probabilities calculated from the model that included either clinical factors and delayed-phase SUVmax ≥0.087 or clinical factors and maximum standardized uptake (SUV) increasing rate (SUV-IR) ≥ 0.100, it significantly increased the sensitivity, specificity, and accuracy (87.5%, 65.7%, and 75.2%, respectively). The use of predictive models that include clinical factors and delayed-phase SUVmax and SUV-IR improve preoperative nodal diagnosis. Copyright © 2012 Elsevier Inc. All rights reserved.
... monitor the brain's activity and detect abnormalities. Single-photon emission computerized tomography (SPECT). The scan image varies ... off anti-seizure drugs after a year or two. By Mayo Clinic Staff . Mayo Clinic Footer Legal ...
... your doctor might order additional imaging called single-photon emission computerized tomography (SPECT). This imaging can help ... radioactivity from the tracers is usually completely eliminated two days after the scan. Results A doctor who ...
Computed gray levels in multislice and cone-beam computed tomography.
Azeredo, Fabiane; de Menezes, Luciane Macedo; Enciso, Reyes; Weissheimer, Andre; de Oliveira, Rogério Belle
2013-07-01
Gray level is the range of shades of gray in the pixels, representing the x-ray attenuation coefficient that allows for tissue density assessments in computed tomography (CT). An in-vitro study was performed to investigate the relationship between computed gray levels in 3 cone-beam CT (CBCT) scanners and 1 multislice spiral CT device using 5 software programs. Six materials (air, water, wax, acrylic, plaster, and gutta-percha) were scanned with the CBCT and CT scanners, and the computed gray levels for each material at predetermined points were measured with OsiriX Medical Imaging software (Geneva, Switzerland), OnDemand3D (CyberMed International, Seoul, Korea), E-Film (Merge Healthcare, Milwaukee, Wis), Dolphin Imaging (Dolphin Imaging & Management Solutions, Chatsworth, Calif), and InVivo Dental Software (Anatomage, San Jose, Calif). The repeatability of these measurements was calculated with intraclass correlation coefficients, and the gray levels were averaged to represent each material. Repeated analysis of variance tests were used to assess the differences in gray levels among scanners and materials. There were no differences in mean gray levels with the different software programs. There were significant differences in gray levels between scanners for each material evaluated (P <0.001). The software programs were reliable and had no influence on the CT and CBCT gray level measurements. However, the gray levels might have discrepancies when different CT and CBCT scanners are used. Therefore, caution is essential when interpreting or evaluating CBCT images because of the significant differences in gray levels between different CBCT scanners, and between CBCT and CT values. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Arisan, Volkan; Karabuda, Zihni Cüneyt; Avsever, Hakan; Özdemir, Tayfun
2013-12-01
The relationship of conventional multi-slice computed tomography (CT)- and cone beam CT (CBCT)-based gray density values and the primary stability parameters of implants that were placed by stereolithographic surgical guides were analyzed in this study. Eighteen edentulous jaws were randomly scanned by a CT (CT group) or a CBCT scanner (CBCT group) and radiographic gray density was measured from the planned implants. A total of 108 implants were placed, and primary stability parameters were measured by insertion torque value (ITV) and resonance frequency analysis (RFA). Radiographic and subjective bone quality classification (BQC) was also classified. Results were analyzed by correlation tests and multiple regressions (p < .05). CBCT-based gray density values (765 ± 97.32 voxel value) outside the implants were significantly higher than those of CT-based values (668.4 ± 110 Hounsfield unit, p < .001). Significant relations were found among the gray density values outside the implants, ITV (adjusted r(2) = 0.6142, p = .001 and adjusted r(2) = 0.5166, p = .0021), and RFA (adjusted r(2) = 0.5642, p = .0017 and adjusted r(2) = 0.5423, p = .0031 for CT and CBCT groups, respectively). Data from radiographic and subjective BQC were also in agreement. Similar to the gray density values of CT, that of CBCT could also be predictive for the subjective BQC and primary implant stability. Results should be confirmed on different CBCT scanners. © 2012 Wiley Periodicals, Inc.
Trenkwalder, Teresa; Lahmann, Anna Lena; Nowicka, Magdalena; Pellegrini, Costanza; Rheude, Tobias; Mayr, N Patrick; Voss, Stephanie; Bleiziffer, Sabine; Lange, Rüdiger; Joner, Michael; Kasel, Albert M; Kastrati, Adnan; Schunkert, Heribert; Husser, Oliver; Hadamitzky, Martin; Hengstenberg, Christian
2018-02-21
Multislice computed tomography (MSCT) has emerged as the mainstay in patients planned for transcatheter aortic valve implantation (TAVI). Incidental findings (IF) in MSCT are common. However, the exact incidence, clinical relevance and further consequences of IF are unclear and it is controversial whether IF adversely affect patients' outcome. We analyzed MSCT data of 1050 patients screened for TAVI between January 2011 and December 2014. Median follow-up of patients was 20 months. In total, 3194 IF were identified, which were classified into clinically non-relevant IF (2872, 90%) and clinically relevant IF (322, 10%). In 25% of patients (258/1050) at least one clinically relevant IF was present. Age (80 ± 7 vs. 80 ± 7 years; p = 0.198) and EuroSCORE II (3.6% [2.1-5.7] vs. 3.6% [2.1-5.9]; p = 0.874) was similar between patients with and without a clinically relevant IF. TAVI was performed less frequently in patients with a clinically relevant IF (76% vs. 85%; p < 0.001), with more patients receiving surgical aortic valve replacement in that group (14% vs. 11%; p = 0.042), possibly due to the high rate of incidental aneurysms of the ascending aorta (n = 48). If TAVI was performed mortality did not differ (30-days: 4% vs. 3%; p = 0.339, 1-year: 11% vs. 14%; p = 0.226) between patients with and without a clinically relevant IF. Our study is the largest study to analyze prevalence, clinical relevance and therapeutic consequences of IF during screening for TAVI. IF in pre-procedural MSCT are common and clinically relevant in one-quarter of patients. However, these findings had no impact on overall mortality.
Annuar, Bin Rapaee; Liew, Chee Khoon; Chin, Sze Piaw; Ong, Tiong Kiam; Seyfarth, M Tobias; Chan, Wei Ling; Fong, Yean Yip; Ang, Choon Kiat; Lin, Naing; Liew, Houng Bang; Sim, Kui Hian
2008-01-01
To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). Thirty-two consecutive patients (mean age, 56.5+/-9.7 years) referred for evaluation of coronary artery using 64-slice MSCT also underwent 2DE and CMR within 48h. The global left ventricular function which include left ventricular ejection fraction (LVEF), left ventricular end diastolic volume (LVdV) and left ventricular end systolic volume (LVsV) were determine using the three modalities. Regional wall motion (RWM) was assessed visually in all three modalities. The CMR served as the gold standard for the comparison between 64-slice MSCT with CMR and 2DE with CMR. Statistical analysis included Pearson correlation coefficient, Bland-Altman plots and kappa-statistics. The 64-slice MSCT agreed well with CMR for assessment of LVEF (r=0.92; p<0.0001), LVdV (r=0.98; p<0.0001) and LVsV (r=0.98; p<0.0001). In comparison with 64-slice MSCT, 2DE showed moderate correlation with CMR for the assessment of LVEF (r=0.84; p<0.0001), LVdV (r=0.83; p<0.0001) and LVsV (r=0.80; p<0.0001). However in RWM analysis, 2DE showed better accuracy than 64-slice MSCT (94.3% versus 82.4%) and closer agreement (kappa=0.89 versus 0.63) with CMR. 64-Slice MSCT correlates strongly with CMR in global LV function however in regional LV function 2DE showed better agreement with CMR than 64-slice MSCT.
Ichikawa, Makoto; Sato, Yuichi; Komatsu, Sei; Hirayama, Atsushi; Kodama, Kazuhisa; Saito, Satoshi
2007-06-01
Anomalous right coronary arteries (RCA) arising from the left sinus of Valsalva may cause myocardial ischemia. We evaluated morphological features of anomalous RCA by using multislice computed tomography (MSCT) in relation to myocardial ischemia provoked by myocardial perfusion single-photon emission computed tomography. MSCT was performed in a total of 3, 212 patients by using an Aquillion 16 and a Light Speed Ultra. Retrospective ECG-gated image reconstruction was performed. Volume rendering, axial and curved multiplanar reformatted images were analyzed for the determination of the origin and course of the RCA, the take-off angle of the RCA from the aorta, and size of the RCA orifice. Furthermore, virtual angioscopic images were also used for the evaluation of the RCA orifice structure. Anomalous origins of the RCA were found in 15 patients. In 13 patients, the RCA arose from the left sinus of Valsalva, and in 2 patients it arose from the left main coronary artery as a single coronary artery. The RCA coursed anteriorly between the ascending aorta and pulmonary artery in 14 patients, whereas it had a retroaortic course in 1 patient. Acute angle take-off (<30 degrees ) of the RCA from the aorta and the left main coronary artery was observed in 8 patients, intramural course of the RCA within the aortic wall was observed in 6 patients and a small RCA orifice was observed in 4 patients. Exercise-induced myocardial ischemia was present in 5 patients. Coursing between the aorta and pulmonary artery, acute angle take-off and intramural course were thought to be major causes of exercise-induced ischemia in patients with anomalous origins of the RCA.
Hołda, Mateusz K; Koziej, Mateusz; Wszołek, Karolina; Pawlik, Wiesław; Krawczyk-Ożóg, Agata; Sorysz, Danuta; Łoboda, Piotr; Kuźma, Katarzyna; Kuniewicz, Marcin; Lelakowski, Jacek; Dudek, Dariusz; Klimek-Piotrowska, Wiesława
2017-10-01
The aim of this study is to provide a morphometric description of the left-sided septal pouch (LSSP), left atrial accessory appendages, and diverticula using cardiac multi-slice computed tomography (MSCT) and to compare results between patient subgroups. Two hundred and ninety four patients (42.9% females) with a mean of 69.4±13.1years of age were investigated using MSCT. The presence of the LSSP, left atrial accessory appendages, and diverticula was evaluated. Multiple logistic regression analysis was performed to check whether the presence of additional left atrial structures is associated with increased risk of atrial fibrillation and cerebrovascular accidents. At least one additional left atrial structure was present in 51.7% of patients. A single LSSP, left atrial diverticulum, and accessory appendage were present in 35.7%, 16.0%, and 4.1% of patients, respectively. After adjusting for other risk factors via multiple logistic regression, patients with LSSP are more likely to have atrial fibrillation (OR=2.00, 95% CI=1.14-3.48, p=0.01). The presence of a LSSP was found to be associated with an increased risk of transient ischemic attack using multiple logistic regression analysis after adjustment for other risk factors (OR=3.88, 95% CI=1.10-13.69, p=0.03). In conclusion LSSPs, accessory appendages, and diverticula are highly prevalent anatomic structures within the left atrium, which could be easily identified by MSCT. The presence of LSSP is associated with increased risk for atrial fibrillation and transient ischemic attack. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Odry, Benjamin L.; Kiraly, Atilla P.; Novak, Carol L.; Naidich, David P.; Lerallut, Jean-Francois
2006-03-01
Pulmonary diseases such as bronchiectasis, asthma, and emphysema are characterized by abnormalities in airway dimensions. Multi-slice computed tomography (MSCT) has become one of the primary means to depict these abnormalities, as the availability of high-resolution near-isotropic data makes it possible to evaluate airways at oblique angles to the scanner plane. However, currently, clinical evaluation of airways is typically limited to subjective visual inspection only: systematic evaluation of the airways to take advantage of high-resolution data has not proved practical without automation. We present an automated method to quantitatively evaluate airway lumen diameter, wall thickness and broncho-arterial ratios. In addition, our method provides 3D visualization of these values, graphically illustrating the location and extent of disease. Our algorithm begins by automatic airway segmentation to extract paths to the distal airways, and to create a map of airway diameters. Normally, airway diameters decrease as paths progress distally; failure to taper indicates abnormal dilatation. Our approach monitors airway lumen diameters along each airway path in order to detect abnormal profiles, allowing even subtle degrees of pathologic dilatation to be identified. Our method also systematically computes the broncho-arterial ratio at every terminal branch of the tree model, as a ratio above 1 indicates potentially abnormal bronchial dilatation. Finally, the airway wall thickness is computed at corresponding locations. These measurements are used to highlight abnormal branches for closer inspection, and can be summed to compute a quantitative global score for the entire airway tree, allowing reproducible longitudinal assessment of disease severity. Preliminary tests on patients diagnosed with bronchiectasis demonstrated rapid identification of lack of tapering, which also was confirmed by corresponding demonstration of elevated broncho-arterial ratios.
Kim, Jin-Seok; Im, Sung Il; Shin, Seung Yong; Kang, Jun Hyuk; Na, Jin Oh; Choi, Cheol Ung; Kim, Seong Hwan; Kim, Eung Ju; Rha, Seung-Woon; Park, Chang Gyu; Seo, Hong Seog; Oh, Dong Joo; Hwang, Chun; Kim, Young-Hoon; Yong, Hwan Seok; Lim, Hong Euy
2017-02-01
Functional remodeling of left atrium (LA) after radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) has not been fully elucidated. This study aimed to determine the impact of RFCA on LA transport function in patients who maintained sinus rhythm (SR) after AF ablation. A total of 96 patients (paroxysmal AF [PAF] = 52) who maintained SR during 1 year after AF ablation were enrolled. Multislice computed tomography was performed to determine LA volume (LAV) and LA emptying fraction (LAEF) at pre-RFCA and 1-year post-RFCA. Creatine kinase-MB (CK-MB) and troponin-T levels were analyzed 1-day post-RFCA. At 1-year post-RFCA, mean LAV and LAEF decreased in overall patients. Based on LAEF change (ΔLAEF) cutoff of 5.0%, LAEF reduced in 41 patients (worsened group) and improved or showed no change in 55 patients (preserved group). Compared with preserved group, worsened group had a higher proportion of PAF, higher levels of CK-MB and troponin-T, and additional LA ablation. ΔLAEF was inversely correlated with CK-MB and troponin-T levels. Subgroup analysis showed that LAEF significantly decreased in PAF patients who underwent additional LA ablation. Multivariate analysis revealed that high baseline LAEF and additional LA ablation were independent predictors for worsened LAEF. Although SR was maintained for 1 year after AF ablation, LAEF as well as LAV decreased. The extent of LAEF deterioration was significantly associated with the amount of iatrogenic myocardial damage. Our data indicate that extensive atrial ablation may lead to LA functional deterioration, especially in patients with PAF. © 2016 Wiley Periodicals, Inc.
Czekajska-Chehab, Elżbieta; Tomaszewska, Monika; Olchowik, Grażyna; Tomaszewski, Marek; Adamczyk, Piotr; Drop, Andrzej
2012-07-01
Lipomatous hypertrophy of the interatrial septum (LHIS) is a benign disorder characterized by fat accumulation in the interatrial septum (IAS). The purpose of the study was to analyze the incidental detection of LHIS in patients with various clinical conditions, referred to ECG-gated multislice computed tomography (ECG-MSCT) examinations of the heart. The ECG-MSCT examinations of 5786 patients (2839 women; 2947 men), were analyzed. The examinations were performed using 8-row (1015 patients) and 64-row (4771 patients) MSCT, in pre- and postcontrast scanning. We analyzed the shape of the IAS, density and maximal thickness of IAS, the thickness of the epicardial adipose tissue, and the degree of contact of IAS with the ascending aorta and superior vena cava. We also determined body mass index (BMI) in patients with LHIS. LHIS was detected in 56 (0.96%) patients, with an average age of 61.5±9.8 years. The mean BMI in the analyzed group was 30.1±4.86. During the end-diastolic phase the thickness of IAS was significantly higher (p<0.0001), and on average equaled 18.3 mm. The mean optical density of the IAS was conspicuously higher (p<0.0001) in post-contrast phase than in pre-contrast phase. The thickness of the epicardial adipose tissue in the region of the left atrioventricular groove was on average 15 mm. In all cases the dumbbell shape of IAS was observed. The incidental frequency of LHIS occurrence in patients diagnosed with the ECG-MSCT examinations is about 1%. In most subjects it is linked with a higher BMI and increased thickness of the epicardial adipose tissue.
... seen on a brain-imaging test, such as magnetic resonance imaging (MRI) or computerized tomography (CT). On ... A cohort study. PLOS One. 2013;8:e71467. Magnetic resonance imaging (MRI). National Multiple Sclerosis Society. http:// ...
... tests Chest x-ray CT (computerized tomography, or advanced imaging) scan EKG (electrocardiogram, or heart tracing) Fluids ... Stanton BF, St. Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ed. Philadelphia, PA: Elsevier; ...
CT stands for computerized tomography. In this procedure, a thin X-ray beam is rotated around the ... D image of a section through the body. CT scans are very detailed and provide excellent information ...
CT stands for computerized tomography. In this procedure, a thin X-ray beam is rotated around the ... D image of a section through the body. CT scans are very detailed and provide excellent information ...
Carotid Angioplasty and Stenting
... and of the blood flow to the brain. Magnetic resonance angiography (MRA) or computerized tomography angiography (CTA). ... vessels by using either radiofrequency waves in a magnetic field or by using X-rays with contrast ...
... tests Chest x-ray CT (computerized tomography, or advanced imaging) scan EKG (electrocardiogram, or heart tracing) Fluids ... Stanton BF, St. Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ed. Philadelphia, PA: Elsevier; ...
... either using computerized axial tomography (CAT) scans or magnetic resonance imaging (MRI) – can help to identify strokes and tumors, which can sometimes cause memory loss. “The goal is to rule out factors ...
Wu, Yuefeng Rose; Rego, Lauren L; Christie, Alana L; Lavelle, Rebecca S; Alhalabi, Feras; Zimmern, Philippe E
2016-08-01
We compared the rates of upper tract imaging abnormalities of recurrent urinary tract infections due to bacterial persistence or reinfection. Following institutional review board approval we reviewed a prospectively maintained database of women with documented recurrent urinary tract infections (3 or more per year) and trigonitis. We searched for demographic data, urine culture findings and findings on radiology interpreted upper tract imaging, including renal ultrasound, computerized tomography or excretory urogram. Patients with irretrievable images, absent or incomplete urine culture results for review, no imaging performed, an obvious source of recurrent urinary tract infections or a history of pyelonephritis were excluded from analysis. Of 289 women from 2006 to 2014 with symptomatic recurrent urinary tract infections 116 met study inclusion criteria. Mean ± SD age was 65.0 ± 14.4 years. Of the women 95% were white and 81% were postmenopausal. Almost a third were sexually active and none had prolapse stage 2 or greater. Of the 116 women 48 (41%) had persistent and 68 (59%) had reinfection recurrent urinary tract infection. Imaging included ultrasound in 52 patients, computerized tomography in 26, ultrasound and computerized tomography in 31, and excretory urogram with ultrasound/computerized tomography in 7. Of the total of 58 imaging findings in 55 women 57 (98%) were noncontributory. One case (0.9%) of mild hydronephrosis was noted in the persistent recurrent urinary tract infection group but it was not related to any clinical parameters. Escherichia coli was the dominant bacteria in 71% of persistent and 47% of reinfection recurrent urinary tract infections in the most recently reported urine culture. This study reaffirms that upper tract imaging is not indicated for bacterial reinfection, recurrent urinary tract infections. However, the same conclusion can be extended to recurrent urinary tract infections secondary to bacterial persistence, thus, questioning the routine practice of upper tract studies in white postmenopausal women with recurrent urinary tract infections and trigonitis. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
DOE R&D Accomplishments Database
Hansche, B. D.
1983-01-01
Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.
Initial experience in treating lung cancer with helical tomotherapy
Yartsev, S; Dar, AR; Woodford, C; Wong, E; Bauman, G; Van Dyk, J
2007-01-01
Helical tomotherapy is a new form of image-guided radiation therapy that combines features of a linear accelerator and a helical computed tomography (CT) scanner. Megavoltage CT (MVCT) data allow the verification and correction of patient setup on the couch by comparison and image registration with the kilovoltage CT multi-slice images used for treatment planning. An 84-year-old male patient with Stage III bulky non-small cell lung cancer was treated on a Hi-ART II tomotherapy unit. Daily MVCT imaging was useful for setup corrections and signaled the need to adapt the delivery plan when the patient’s anatomy changed significantly. PMID:21614260
NASA Astrophysics Data System (ADS)
Han, Minah; Jang, Hanjoo; Baek, Jongduk
2018-03-01
We investigate lesion detectability and its trends for different noise structures in single-slice and multislice CBCT images with anatomical background noise. Anatomical background noise is modeled using a power law spectrum of breast anatomy. Spherical signal with a 2 mm diameter is used for modeling a lesion. CT projection data are acquired by the forward projection and reconstructed by the Feldkamp-Davis-Kress algorithm. To generate different noise structures, two types of reconstruction filters (Hanning and Ram-Lak weighted ramp filters) are used in the reconstruction, and the transverse and longitudinal planes of reconstructed volume are used for detectability evaluation. To evaluate single-slice images, the central slice, which contains the maximum signal energy, is used. To evaluate multislice images, central nine slices are used. Detectability is evaluated using human and model observer studies. For model observer, channelized Hotelling observer (CHO) with dense difference-of-Gaussian (D-DOG) channels are used. For all noise structures, detectability by a human observer is higher for multislice images than single-slice images, and the degree of detectability increase in multislice images depends on the noise structure. Variation in detectability for different noise structures is reduced in multislice images, but detectability trends are not much different between single-slice and multislice images. The CHO with D-DOG channels predicts detectability by a human observer well for both single-slice and multislice images.
Few CT Scan Abnormalities Found Even in Neurologically Impaired Learning Disabled Children.
ERIC Educational Resources Information Center
Denckla, Martha Bridge; And Others
1985-01-01
Most of 32 learning disabled children (seven to 14 years old) with neurological lateralization characteristics marked by right and left hemispheres had a normal CT (computerized tomography) scan. (CL)
Prostate Enlargement: Benign Prostatic Hyperplasia (BPH)
... such as ultrasound, a computerized tomography scan, or magnetic resonance imaging to guide the biopsy needle into ... heats and destroys selected portions of prostate tissue. Shields protect the urethra from heat damage. Transurethral microwave ...
SPECT (Single-Photon Emission Computerized Tomography) Scan
... can become damaged or even die. Reduced pumping efficiency. SPECT can show how completely your heart chambers ... radioactive tracer SPECT scans aren't safe for women who are pregnant or breast-feeding because the ...
Non-Hodgkin Lymphoma (For Parents)
... chest X-ray a computerized tomography (CT or CAT) scan , which rotates around the patient and creates an ... ray (Video) Getting an MRI (Video) Getting a CAT Scan (Video) Chemotherapy Hodgkin Lymphoma Stem Cell Transplants Can ...
The mobile hospital technology industry: focus on the computerized tomography scanner.
Hartley, D; Moscovice, I
1996-01-01
This study of firms offering mobile hospital technology to rural hospitals in eight northwestern states found that several permanently parked computerized tomography (CT) units were found where mobile routes had atrophied due to the purchase of fixed units by former mobile CT hospital clients. Based on a criterion of 140 scans per month per unit as a threshold of profitable production, units owned by larger firms (those that operate five or more units) were more likely to be profitable than units owned by smaller firms (71% versus 20%, P = 0.03). A substantial number of rural hospitals lose money on mobile CT due to low Medicare reimbursement. In some areas, mobile hospital technology is a highly competitive industry. Evidence was found that several firms compete in some geographic areas and that some firms have lost hospital clients to competing vendors.
Magnetic resonance imaging and computerized tomography in malignant external otitis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gherini, S.G.; Brackmann, D.E.; Bradley, W.G.
1986-05-01
In malignant external otitis (MEO), determining the anatomic extent of disease and evaluating the physiologic response to therapy remain a problem. Magnetic resonance imaging (MRI) has recently become available in limited clinical settings. Four patients with MEO were evaluated using MRI, computerized tomography (CT), technetium-99 (Tc-99) bone scanning, and gallium-67 citrate (Ga-67 citrate) scanning. MRI is superior to CT, Tc-99 bone scanning, and Ga-67 citrate scanning in evaluating the anatomic extent of soft tissue changes in MEO. MRI alone cannot be relied upon to determine the physiologic response to therapy. MRI can, however, serve as a valuable guide to themore » interpretation of Tc-99 bone and Ga-67 citrate scans, and in this respect, MRI is extremely useful in the treatment of MEO.« less
Uroradiographic manifestations of Burkitt's lymphoma in children
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fernbach, S.K.; Glass, R.B.
1986-05-01
The radiological studies of 18 children with biopsy proved Burkitt's lymphoma were analyzed retrospectively. Before therapy the genitourinary tract was evaluated in 15 children by excretory urography, sonography, computerized tomography and/or gallium citrate scintigraphy. Genitourinary abnormalities were detected in 9 children. Changes due to tumor included renal or ureteral displacement in 4 children, hydronephrosis in 3 and intraparenchymal masses in 4. Extrinsic compression of the bladder causing no compromise of function was seen in only 2 children. Gonadal involvement occurred in 2 boys and 1 girl. The modality of choice for evaluating the genitourinary tract in patients with Burkitt's lymphomamore » has been excretory urography. Since ultrasound and computerized tomography provide more direct information about tumor deposits within the kidney and retroperitoneum, either should be performed in this population before initiation of chemotherapy.« less
Rectus sheath hematoma: three case reports
Kapan, Selin; Turhan, Ahmet N; Alis, Halil; Kalayci, Mustafa U; Hatipoglu, Sinan; Yigitbas, Hakan; Aygun, Ersan
2008-01-01
Introduction Rectus sheath hematoma is an uncommon cause of acute abdominal pain. It is an accumulation of blood in the sheath of the rectus abdominis, secondary to rupture of an epigastric vessel or muscle tear. It could occur spontaneously or after trauma. They are usually located infraumblically and often misdiagnosed as acute abdomen, inflammatory diseases or tumours of the abdomen. Case presentation We reported three cases of rectus sheath hematoma presenting with a mass in the abdomen and diagnosed by computerized tomography. The patients recovered uneventfully after bed rest, intravenous fluid replacement, blood transfusion and analgesic treatment. Conclusion Rectus sheath hematoma is a rarely seen pathology often misdiagnosed as acute abdomen that may lead to unnecessary laparotomies. Computerized tomography must be chosen for definitive diagnosis since ultrasonography is subject to error due to misinterpretation of the images. Main therapy is conservative management. PMID:18221529
Compact cold stage for micro-computerized tomography imaging of chilled or frozen samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hullar, Ted; Anastasio, Cort, E-mail: canastasio@ucdavis.edu; Paige, David F.
2014-04-15
High resolution X-ray microCT (computerized tomography) can be used to image a variety of objects, including temperature-sensitive materials. In cases where the sample must be chilled or frozen to maintain sample integrity, either the microCT machine itself must be placed in a refrigerated chamber, or a relatively expensive commercial cold stage must be purchased. We describe here the design and construction of a low-cost custom cold stage suitable for use in a microCT imaging system. Our device uses a boron nitride sample holder, two-stage Peltier cooler, fan-cooled heat sink, and electronic controller to maintain sample temperatures as low as −25 °Cmore » ± 0.2 °C for the duration of a tomography acquisition. The design does not require modification to the microCT machine, and is easily installed and removed. Our custom cold stage represents a cost-effective solution for refrigerating CT samples for imaging, and is especially useful for shared equipment or machines unsuitable for cold room use.« less
Acar, Buket; Kamburoğlu, Kıvanç; Tatar, İlkan; Arıkan, Volkan; Çelik, Hakan Hamdi; Yüksel, Selcen; Özen, Tuncer
2015-12-01
This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.
Kao, S Y; Chou, J; Lo, J; Yang, J; Chou, A P; Joe, C J; Chang, R C
1999-04-01
Roentgenographic examination has long been a useful diagnostic tool for temporo-mandibular joint (TMJ) disease. The methods include TMJ tomography, panoramic radiography and computerized tomography (CT) scan with or without injection of contrast media. Recently, three-dimensional CT (3D-CT), reconstructed from the two-dimensional image of a CT scan to simulate the soft tissue or bony structure of the real target, was proposed. In this report, a case of TMJ ankylosis due to traumatic injury is presented. 3D-CT was employed as one of the presurgical roentgenographic diagnostic tools. The conventional radiographic examination including panoramic radiography and tomography showed lesions in both sides of the mandible. CT scanning further suggested that the right-sided lesion was more severe than that on the left. With 3D-CT image reconstruction the size and extent of the lesions were clearly observable. The decision was made to proceed with an initial surgical approach on the right side. With condylectomy and condylar replacement using an autogenous costochondral graft on the right side, the range of mouth opening improved significantly. In this case report, 3D-CT demonstrates its advantages as a tool for the correct and precise diagnosis of TMJ ankylosis.
Mini-Stroke vs. Regular Stroke: What's the Difference?
... may need various diagnostic tests, such as a magnetic resonance imaging (MRI) scan or a computerized tomography ( ... org," "Mayo Clinic Healthy Living," and the triple-shield Mayo Clinic logo are trademarks of Mayo Foundation ...
Mineral & Bone Disorder in Chronic Kidney Disease
... stages of CKD. Slowed bone growth leads to short stature, which may remain with a child into adulthood. ... and local anesthetic. The health care provider uses imaging techniques such as ultrasound or a computerized tomography ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, W; Yin, F; Wang, C
Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution ofmore » VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while maintaining the estimation accuracy. Estimation using slices sampled uniformly through the tumor achieved better accuracy than slices sampled non-uniformly. Conclusions: Preliminary studies showed that it is feasible to generate VC-MRI from multi-slice sparsely-sampled 2D-cine images for real-time 3D-target verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.« less
Zeng, Rongping; Petrick, Nicholas; Gavrielides, Marios A; Myers, Kyle J
2011-10-07
Multi-slice computed tomography (MSCT) scanners have become popular volumetric imaging tools. Deterministic and random properties of the resulting CT scans have been studied in the literature. Due to the large number of voxels in the three-dimensional (3D) volumetric dataset, full characterization of the noise covariance in MSCT scans is difficult to tackle. However, as usage of such datasets for quantitative disease diagnosis grows, so does the importance of understanding the noise properties because of their effect on the accuracy of the clinical outcome. The goal of this work is to study noise covariance in the helical MSCT volumetric dataset. We explore possible approximations to the noise covariance matrix with reduced degrees of freedom, including voxel-based variance, one-dimensional (1D) correlation, two-dimensional (2D) in-plane correlation and the noise power spectrum (NPS). We further examine the effect of various noise covariance models on the accuracy of a prewhitening matched filter nodule size estimation strategy. Our simulation results suggest that the 1D longitudinal, 2D in-plane and NPS prewhitening approaches can improve the performance of nodule size estimation algorithms. When taking into account computational costs in determining noise characterizations, the NPS model may be the most efficient approximation to the MSCT noise covariance matrix.
Nemsadze, G; Urushadze, O
2011-11-01
Using of mutislice spiral CT as first line examination for the diagnosis of Acute Facial trauma in the setting of Polytrauma reduces both: valuable time and cost of patient treatment. After a brief clinical examination, MDCT was performed depending on the area of injury, using a slice thickness of 0.65 mm. The obtained data were analyzed using 3D, MIP and Standard axial with Bone reconstruction protocols. 64 polytrauma patients were evaluated with both Anterior and Lateral craniography (plain skull X ray: AP and Lateral) and Multi Slice CT. Craniography detected only 18 cases of traumatic injuries of facial bones, but exact range of dislocation and accurate management plan could not be established. In the same 64 cases, Multislice CT revealed localization of all existed fractures, range of fragment dislocation, soft tissue damage and status of Paranasal sinus in 62 cases (96.8%). In two cases MS CT missed the facial fracture, in one case the examination was complicated because of bone thinness and numerous fracture fragments, in another multiple foreign body artifacts complicated the investigation. The study results show that, CT investigation based on our MDCT polytrauma protocol, detects all more or less serious facial bone injuries.
Biopsy: Types of Biopsy Procedures Used to Diagnose Cancer
... procedure — such as X-ray, computerized tomography (CT), magnetic resonance imaging (MRI) or ultrasound — with a needle ... org," "Mayo Clinic Healthy Living," and the triple-shield Mayo Clinic logo are trademarks of Mayo Foundation ...
Intravenous leiomyomatosis of the uterus with extension to the right heart
2011-01-01
A 42-year-old woman admitted with debilitation and engorgement both lower extremities. Transthoracic two-dimensional echocardiography, abdominal ultrasound and computerized tomography revealed a lobulated pelvic mass, a mass within right internal iliac vein, both common iliac vein, as well as the inferior vena cava, extending into the right atrium. In addition, echocardiography and abdominal ultrasound showed the tumor of right atrium and inferior vena cave has no stalk and has well-demarcated borders with the wall of right atrium and inferior vena cave. Hence, the presumptive diagnosis of IVL was made by echocardiography and abdominal ultrasound and the presumptive diagnosis of sarcoma with invasion in right internal iliac vein, both common iliac vein, the inferior vena cava, as well as the right atrium was made by multi-detector-row computerized tomography. The patient underwent a one-stage combined multidisciplinary thoraco-abdominal operation under general anaesthetic. Subsequently the pathologic report confirmed IVL. PMID:21943238
NASA Astrophysics Data System (ADS)
Zhou, Chen; Lei, Yong; Li, Bofeng; An, Jiachun; Zhu, Peng; Jiang, Chunhua; Zhao, Zhengyu; Zhang, Yuannong; Ni, Binbin; Wang, Zemin; Zhou, Xuhua
2015-12-01
Global Positioning System (GPS) computerized ionosphere tomography (CIT) and ionospheric sky wave ground backscatter radar are both capable of measuring the large-scale, two-dimensional (2-D) distributions of ionospheric electron density (IED). Here we report the spatial and temporal electron density results obtained by GPS CIT and backscatter ionogram (BSI) inversion for three individual experiments. Both the GPS CIT and BSI inversion techniques demonstrate the capability and the consistency of reconstructing large-scale IED distributions. To validate the results, electron density profiles obtained from GPS CIT and BSI inversion are quantitatively compared to the vertical ionosonde data, which clearly manifests that both methods output accurate information of ionopsheric electron density and thereby provide reliable approaches to ionospheric soundings. Our study can improve current understanding of the capability and insufficiency of these two methods on the large-scale IED reconstruction.
A motion artefact study and locally deforming objects in computerized tomography
NASA Astrophysics Data System (ADS)
Hahn, Bernadette N.
2017-11-01
Movements of the object during the data collection in computerized tomography can introduce motion artefacts in the reconstructed image. They can be reduced by employing information about the dynamic behaviour within the reconstruction step. However, inaccuracies concerning the movement are inevitable in practice. In this article, we give an explicit characterization of what is visible in an image obtained by a reconstruction algorithm with incorrect motion information. Then, we use this result to study in detail the situation of locally deforming objects, i.e. individual parts of the object have a different dynamic behaviour. In this context, we prove that additional artefacts arise due to the global nature of the Radon transform, even if the motion is exactly known. Based on our analysis, we propose a numerical scheme to reduce these artefacts in the reconstructed image. All our results are illustrated by numerical examples.
Radiation Hard Sensors for Surveillance.
1988-03-11
track position measurements were noted. E. Heijne (CERN) reported on the degradation of silicon detectors for doses larger than 2x10 11 muons /cm 2...Workshop on Transmission and Emission Computerized Tomography , July 1978, Seoul, Korea Nahmias C., Kenyon D.B., Garnett E.S.: Optimization of...crystal size in emission computed tomography . IEEE Trans ,.-.e Nucl Sci NS-27: 529-532, 1980. Mullani N.A., Ficke D.C., Ter-Pogossian M.M.: Cesium Fluoride
Determination of dosimetric quantities in pediatric abdominal computed tomography scans*
Jornada, Tiago da Silva; da Silva, Teógenes Augusto
2014-01-01
Objective Aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods The study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results No significant difference was observed in the values for weighted air kerma index (CW), but the differences were relevant in values for volumetric air kerma index (CVOL), air kerma-length product (PKL,CT) and effective dose. Conclusion Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, PKL,CT and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. PMID:25741103
Intraoperative computed tomography.
Tonn, J C; Schichor, C; Schnell, O; Zausinger, S; Uhl, E; Morhard, D; Reiser, M
2011-01-01
Intraoperative computed tomography (iCT) has gained increasing impact among modern neurosurgical techniques. Multislice CT with a sliding gantry in the OR provides excellent diagnostic image quality in the visualization of vascular lesions as well as bony structures including skull base and spine. Due to short acquisition times and a high spatial and temporal resolution, various modalities such as iCT-angiography, iCT-cerebral perfusion and the integration of intraoperative navigation with automatic re-registration after scanning can be performed. This allows a variety of applications, e.g. intraoperative angiography, intraoperative cerebral perfusion studies, update of cerebral and spinal navigation, stereotactic procedures as well as resection control in tumour surgery. Its versatility promotes its use in a multidisciplinary setting. Radiation exposure is comparable to standard CT systems outside the OR. For neurosurgical purposes, however, new hardware components (e.g. a radiolucent headholder system) had to be developed. Having a different range of applications compared to intraoperative MRI, it is an attractive modality for intraoperative imaging being comparatively easy to install and cost efficient.
Koivisto, Juha; Kiljunen, Timo; Wolff, Jan; Kortesniemi, Mika
2013-12-01
The objective of this study was to assess and compare the organ and effective doses in the knee area resulting from different commercially available multislice computed tomography devices (MSCT), one cone beam computed tomography device (CBCT) and one conventional X-ray radiography device using MOSFET dosemeters and an anthropomorphic RANDO knee phantom. Measurements of the MSCT devices resulted in effective doses ranging between 27 and 48 µSv. The CBCT measurements resulted in an effective dose of 12.6 µSv. The effective doses attained using the conventional radiography device were 1.8 µSv for lateral and 1.2 µSv for anterior-posterior projections. The effective dose resulting from conventional radiography was considerably lower than those recorded for the CBCT and MSCT devices. The MSCT effective dose results were two to four times higher than those measured on the CBCT device. This study demonstrates that CBCT can be regarded as a potential low-dose 3D imaging technique for knee examinations.
Konecki, Dariusz; Pacho, Ryszard; Rowiński, Olgierd
2017-01-01
Summary Background Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. Material/Methods The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. Results The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. Conclusions CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding. PMID:29662594
Guzman, Marco; Miranda, Gonzalo; Olavarria, Christian; Madrid, Sofia; Muñoz, Daniel; Leiva, Miguel; Lopez, Lorena; Bortnem, Cori
2017-01-01
The present study aimed to observe the effect of two types of tubes on vocal tract bidimensional and tridimensional images. Ten participants with hyperfunctional dysphonia were included. Computerized tomography was performed during production of sustained [a:], followed by sustained phonation into a drinking straw, and then repetition of sustained [a:]. A similar procedure was performed with a stirring straw after 15 minutes of vocal rest. Anatomic distances and area measures were obtained from computerized tomography midsagittal and transversal images. Vocal tract total volume was also calculated. During tube phonation, increases were measured in the vertical length of the vocal tract, oropharyngeal area, hypopharyngeal area, outlet of the epilaryngeal tube, and inlet to the lower pharynx. Also, the larynx was lower, and more closure was noted between the velum and the nasal passage. Tube phonation causes an increased total vocal tract volume, mostly because of the increased cross-sectional areas in the pharyngeal region. This change is more prominent when the tube offers more airflow resistance (stirring straw) compared with less airflow resistance (drinking straw). Based on our data and previous studies, it seems that vocal tract changes are not dependent on the voice condition (vocally trained, untrained, or disordered voices), but on the exercise itself and the type of instructions given to subjects. Tube phonation is a good option to reach therapeutic goals (eg, wide pharynx and low larynx) without giving biomechanical instructions, but only asking patients to feel easy voice and vibratory sensations. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Yu, Lifeng; Chen, Baiyu; Kofler, James M.; Favazza, Christopher P.; Leng, Shuai; Kupinski, Matthew A.; McCollough, Cynthia H.
2017-01-01
Purpose Model observers have been successfully developed and used to assess the quality of static 2D CT images. However, radiologists typically read images by paging through multiple 2D slices (i.e. multi-slice reading). The purpose of this study was to correlate human and model observer performance in a low-contrast detection task performed using both 2D and multi-slice reading, and to determine if the 2D model observer still correlate well with human observer performance in multi-slice reading. Methods A phantom containing 18 low-contrast spheres (6 sizes × 3 contrast levels) was scanned on a 192-slice CT scanner at 5 dose levels (CTDIvol = 27, 13.5, 6.8, 3.4, and 1.7 mGy), each repeated 100 times. Images were reconstructed using both filtered-backprojection (FBP) and an iterative reconstruction (IR) method (ADMIRE, Siemens). A 3D volume of interest (VOI) around each sphere was extracted and placed side-by-side with a signal-absent VOI to create a 2-alternative forced choice (2AFC) trial. Sixteen 2AFC studies were generated, each with 100 trials, to evaluate the impact of radiation dose, lesion size and contrast, and reconstruction methods on object detection. In total, 1600 trials were presented to both model and human observers. Three medical physicists acted as human observers and were allowed to page through the 3D volumes to make a decision for each 2AFC trial. The human observer performance was compared with the performance of a multi-slice channelized Hotelling observer (CHO_MS), which integrates multi-slice image data, and with the performance of previously validated CHO, which operates on static 2D images (CHO_2D). For comparison, the same 16 2AFC studies were also performed in a 2D viewing mode by the human observers and compared with the multi-slice viewing performance and the two CHO models. Results Human observer performance was well correlated with the CHO_2D performance in the 2D viewing mode (Pearson product-moment correlation coefficient R=0.972, 95% confidence interval (CI): 0.919 to 0.990) and with the CHO_MS performance in the multi-slice viewing mode (R=0.952, 95% CI: 0.865 to 0.984). The CHO_2D performance, calculated from the 2D viewing mode, also had a strong correlation with human observer performance in the multi-slice viewing mode (R=0.957, 95% CI: 879 to 0.985). Human observer performance varied between the multi-slice and 2D modes. One reader performed better in the multi-slice mode (p=0.013); whereas the other two readers showed no significant difference between the two viewing modes (p=0.057 and p=0.38). Conclusions A 2D CHO model is highly correlated with human observer performance in detecting spherical low contrast objects in multi-slice viewing of CT images. This finding provides some evidence for the use of a simpler, 2D CHO to assess image quality in clinically relevant CT tasks where multi-slice viewing is used. PMID:28555878
Yu, Lifeng; Chen, Baiyu; Kofler, James M; Favazza, Christopher P; Leng, Shuai; Kupinski, Matthew A; McCollough, Cynthia H
2017-08-01
Model observers have been successfully developed and used to assess the quality of static 2D CT images. However, radiologists typically read images by paging through multiple 2D slices (i.e., multislice reading). The purpose of this study was to correlate human and model observer performance in a low-contrast detection task performed using both 2D and multislice reading, and to determine if the 2D model observer still correlate well with human observer performance in multislice reading. A phantom containing 18 low-contrast spheres (6 sizes × 3 contrast levels) was scanned on a 192-slice CT scanner at five dose levels (CTDI vol = 27, 13.5, 6.8, 3.4, and 1.7 mGy), each repeated 100 times. Images were reconstructed using both filtered-backprojection (FBP) and an iterative reconstruction (IR) method (ADMIRE, Siemens). A 3D volume of interest (VOI) around each sphere was extracted and placed side-by-side with a signal-absent VOI to create a 2-alternative forced choice (2AFC) trial. Sixteen 2AFC studies were generated, each with 100 trials, to evaluate the impact of radiation dose, lesion size and contrast, and reconstruction methods on object detection. In total, 1600 trials were presented to both model and human observers. Three medical physicists acted as human observers and were allowed to page through the 3D volumes to make a decision for each 2AFC trial. The human observer performance was compared with the performance of a multislice channelized Hotelling observer (CHO_MS), which integrates multislice image data, and with the performance of previously validated CHO, which operates on static 2D images (CHO_2D). For comparison, the same 16 2AFC studies were also performed in a 2D viewing mode by the human observers and compared with the multislice viewing performance and the two CHO models. Human observer performance was well correlated with the CHO_2D performance in the 2D viewing mode [Pearson product-moment correlation coefficient R = 0.972, 95% confidence interval (CI): 0.919 to 0.990] and with the CHO_MS performance in the multislice viewing mode (R = 0.952, 95% CI: 0.865 to 0.984). The CHO_2D performance, calculated from the 2D viewing mode, also had a strong correlation with human observer performance in the multislice viewing mode (R = 0.957, 95% CI: 879 to 0.985). Human observer performance varied between the multislice and 2D modes. One reader performed better in the multislice mode (P = 0.013); whereas the other two readers showed no significant difference between the two viewing modes (P = 0.057 and P = 0.38). A 2D CHO model is highly correlated with human observer performance in detecting spherical low contrast objects in multislice viewing of CT images. This finding provides some evidence for the use of a simpler, 2D CHO to assess image quality in clinically relevant CT tasks where multislice viewing is used. © 2017 American Association of Physicists in Medicine.
Rare extraskeletal Ewing's sarcoma mimicking as adenocarcinoma of the sigmoid.
Mertens, Michelle; Haenen, Filip W N; Siozopoulou, Vasiliki; Van Cleemput, Marc
2017-06-01
Extraskeletal Ewing's sarcoma (EES) is a rare finding in comparison with Ewing's sarcoma of bone and usually manifests in young patients. However, even in older patients, one must consider the diagnosis. In this case, we describe a 52-year-old woman diagnosed with EES, mimicking as adenocarcinoma of the sigmoid. The tumor was not visualized by a multi-slice spiral computed tomography of the abdomen and pelvis with intravenous contrast, and eventually the diagnosis was made by positive immunohistochemical staining for CD99 and by molecular testing for EWSR1 translocation. This combination of the patient's age and the localization of the tumor mimicking an adenocarcinoma of the sigmoid has never been described before.
Selcuk, Adin; Ozer, Tulay; Esen, Erkan; Ozdogan, Fatih; Ozel, Halil Erdem; Yuce, Turgut; Caliskan, Sebla; Dasli, Sinem; Bilal, Nagihan; Genc, Gulden; Genc, Selahattin
2017-05-01
To investigate changes in upper airway volume parameters measured by computerized tomography scans in patients with surgically treated by anterior palatoplasty of whom having pure snoring and mild-moderate obstructive sleep apnea. A prospective study on consecutively anterior palatoplasty performed pure snoring and obstructive sleep apnea patients. Computerized tomography scans were obtained preoperatively and following anterior palatoplasty procedure to measure changes in upper airway volume. Patients underwent diagnostic drug induced sleep endoscopy to assess the site of obstruction. Preoperative and postoperative measurements were compared using student's t test and Chi-square test. Twenty-two patients (16 men and 6 women, age 48.22 ± 9.23, body mass index 25.85 ± 2.57) completed the trial. Anterior palatoplasty was associated with an increase in total upper airway volume from 4.81 ± 1.73 cm 3 before treatment to 6.57 ± 2.03 cm 3 after treatment (p < 0.005). Change in soft palate thickness did not vary significantly (p < 0.039). The mean soft palate length has changed from 4.13 ± 0.41 to 3.93 ± 0.51 cm (p < 0.001). The preoperative and postoperative measurements of cross-sectional areas and volumes all showed significant difference except velopharynx minimal lateral airway dimension. The operational procedure increased the total upper airway volume much more in men than in women (p < 0.05). Results of this study indicate that anterior palatoplasty operation appears to produce significant increase in upper airway volume and cross sectional area. It does not seem to have an effect on lateral airway dimension. Computerized tomography is a quick and noninvasive imaging technique that allows for quantitative assessment of the velopharyngeal patency changes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raynaud, C.; Rancurel, G.; Samson, Y.
1987-01-01
Seventeen chronic cerebral infarcts were investigated by a highly sensitive, dedicated brain single photon emission computerized tomography system using /sup 123/I-isopropyl iodoamphetamine (IMP) and /sup 133/Xe. IMP uptake was measured 10 minutes, 2 hours, and 5 hours after injection, and regional cerebral blood flow was measured with 133Xe. In 4 cases a positron emission tomography system was used to measure the rCBF and the regional metabolic rate of oxygen with C15O2 and 15O2. The results obtained allowed us to identify 2 abnormal zones. One, the central area, was characterized by a severe decrease in IMP uptake and rCBF averaging 34%more » and 46% respectively and by a hypodense image on the x-ray computerized tomography scan. The second, the periinfarct or ''peripheral area'' was characterized by a moderate decrease in IMP uptake and regional cerebral blood flow averaging 13 and 19% respectively; this area extended around the central area and had a normal density on computerized tomography scan. The IMP hypofixation of the peripheral area observed at the 10th minute tended to disappear at the 5th hour. The volume of this area was often found to be quite large, covering more than 30% of a hemisphere whereas the central area did not exceed 25%. Volume appeared to be correlated with the neurological status of the patient. The nature of the peripheral area is not established with certainty. It may be caused by deafferentation of areas not directly affected by the ischemic insult and/or selective ischemic neuronal loss. The results stress the important role played by the peripheral area, which may be useful in establishing the prognosis and evaluating the efficacy of therapy in individual stroke cases.« less
Sheriff, Hemin Oathman; Mahmood, Kawa Abdullah; Hamawandi, Nzar; Mirza, Aram Jamal; Hawas, Jawad; Moreno, Esther Granell; Clavero, Juan Antonio; Hankins, Christopher; Masia, Jaume
2018-05-18
The supraclavicular artery flap is an excellent flap for head and neck reconstruction. The aim of this study is to assess imaging techniques to define the precise vascular boundaries of this flap. Six imaging techniques were used for supraclavicular artery mapping in 65 cases; handheld Doppler, triplex ultrasound, computed tomography angiography, magnetic resonance angiography, digital subtraction angiography, and indocyanine green angiography. We checked the site of the perforators, the course of a supraclavicular artery, and anatomical mapping of the supraclavicular artery. Handheld Doppler identified perforators' sites in 80% of the cases but showed no results for the course of the vessel. Triplex ultrasound identified the site of perforators in 52.9%, and partial mapping of the course of a supraclavicular artery in 64.7% of the cases. Computerized tomography angiography showed the site of perforators in 60%, and the course of supraclavicular artery completely in 45%, and partially in an additional 30%of the cases examined. Magnetic resonance angiography showed negative results for all parameters. Digital subtraction angiography showed the partial course of a supraclavicular artery in 62.5%, but showed no perforators. Indocyanine green angiography showed the site of perforators in 60% and a partial course of supraclavicular artery distal to perforators in 60%.Anatomical mapping of the vessel was possible with computerized tomography angiogram completely in 45%, and partially in 30%, and was also possible with indocyanine green angiography partially in 60%. Computerized tomography angiography showed best results in the mapping of the supraclavicular artery, but with an inability to define the perforator perfusion territories, and also with risks of irradiation, while indocyanine green angiography is a good alternative as it could precisely map the superficial course of the artery and angiosomes, with no radiation exposure. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Clinical results of computerized tomography-based simulation with laser patient marking.
Ragan, D P; Forman, J D; He, T; Mesina, C F
1996-02-01
Accuracy of a patient treatment portal marking device and computerized tomography (CT) simulation have been clinically tested. A CT-based simulator has been assembled based on a commercial CT scanner. This includes visualization software and a computer-controlled laser drawing device. This laser drawing device is used to transfer the setup, central axis, and/or radiation portals from the CT simulator to the patient for appropriate patient skin marking. A protocol for clinical testing is reported. Twenty-five prospectively, sequentially accessioned patients have been analyzed. The simulation process can be completed in an average time of 62 min. Under many cases, the treatment portals can be designed and the patient marked in one session. Mechanical accuracy of the system was found to be within +/- 1mm. The portal projection accuracy in clinical cases is observed to be better than +/- 1.2 mm. Operating costs are equivalent to the conventional simulation process it replaces. Computed tomography simulation is a clinical accurate substitute for conventional simulation when used with an appropriate patient marking system and digitally reconstructed radiographs. Personnel time spent in CT simulation is equivalent to time in conventional simulation.
Evaluation of computed tomography numbers for treatment planning of lung cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mira, J.G.; Fullerton, G.D.; Ezekiel, J.
1982-09-01
Computerized tomography numbers (CTN) were evaluated in 32 computerized tomography scans performed on patients with carcinoma of the lung, with the aim of evaluating CTN in normal (lung, blood, muscle, etc) and pathologic tissues (tumor, atelectasis, effusion, post-radiation fibrosis). Our main findings are: 1. Large individual CTN variations are encountered in both normal and pathologic tissues, above and below mean values. Hence, absolute numbers are meaningless. Measurements of any abnormal intrathoracic structure should be compared in relation to normal tissue CTN values in the same scan. 2. Tumor and complete atelectasis have CTN basically similar to soft tissue. Hence, thesemore » numbers are not useful for differential diagnosis. 3. Effusions usually have lower CTN and can be distinguished from previous situations. 4. Dosimetry based on uniform lung density assumptions (i.e., 300 mg/cm/sup 3/) might produce substantial dose errors as lung CTN exhibit variations indicating densities well above and below this value. 5. Preliminary information indicates that partial atelectasis and incipient post-radiation fibrosis can have very low CTN. Hence, they can be differentiated from solid tumors in certain cases, and help in differential diagnosis of post radiation recurrence within the radiotherapy field versus fibrosis.« less
Sarcoidosis Occurring After Lymphoma
London, Jonathan; Grados, Aurélie; Fermé, Christophe; Charmillon, Alexandre; Maurier, François; Deau, Bénédicte; Crickx, Etienne; Brice, Pauline; Chapelon-Abric, Catherine; Haioun, Corinne; Burroni, Barbara; Alifano, Marco; Le Jeunne, Claire; Guillevin, Loïc; Costedoat-Chalumeau, Nathalie; Schleinitz, Nicolas; Mouthon, Luc; Terrier, Benjamin
2014-01-01
Abstract Sarcoidosis is a granulomatous disease that most frequently affects the lungs with pulmonary infiltrates and/or bilateral hilar and mediastinal lymphadenopathy. An association of sarcoidosis and lymphoproliferative disease has previously been reported as the sarcoidosis-lymphoma syndrome. Although this syndrome is characterized by sarcoidosis preceding lymphoma, very few cases of sarcoidosis following lymphoma have been reported. We describe the clinical, biological, and radiological characteristics and outcome of 39 patients presenting with sarcoidosis following lymphoproliferative disease, including 14 previously unreported cases and 25 additional patients, after performing a literature review. Hodgkin lymphoma and non-Hodgkin lymphoma were equally represented. The median delay between lymphoma and sarcoidosis was 18 months. Only 16 patients (41%) required treatment. Sarcoidosis was of mild intensity or self-healing in most cases, and overall clinical response to sarcoidosis was excellent with complete clinical response in 91% of patients. Sarcoidosis was identified after a follow-up computerized tomography scan (CT-scan) or 18fluorodeoxyglucose-positron emission tomography/computerized tomography (18FDG-PET/CT) evaluation in 18/34 patients (53%). Sarcoidosis is therefore a differential diagnosis to consider when lymphoma relapse is suspected on a CT-scan or 18FDG-PET/CT, emphasizing the necessity to rely on histological confirmation of lymphoma relapse. PMID:25380084
3D temporal subtraction on multislice CT images using nonlinear warping technique
NASA Astrophysics Data System (ADS)
Ishida, Takayuki; Katsuragawa, Shigehiko; Kawashita, Ikuo; Kim, Hyounseop; Itai, Yoshinori; Awai, Kazuo; Li, Qiang; Doi, Kunio
2007-03-01
The detection of very subtle lesions and/or lesions overlapped with vessels on CT images is a time consuming and difficult task for radiologists. In this study, we have developed a 3D temporal subtraction method to enhance interval changes between previous and current multislice CT images based on a nonlinear image warping technique. Our method provides a subtraction CT image which is obtained by subtraction of a previous CT image from a current CT image. Reduction of misregistration artifacts is important in the temporal subtraction method. Therefore, our computerized method includes global and local image matching techniques for accurate registration of current and previous CT images. For global image matching, we selected the corresponding previous section image for each current section image by using 2D cross-correlation between a blurred low-resolution current CT image and a blurred previous CT image. For local image matching, we applied the 3D template matching technique with translation and rotation of volumes of interests (VOIs) which were selected in the current and the previous CT images. The local shift vector for each VOI pair was determined when the cross-correlation value became the maximum in the 3D template matching. The local shift vectors at all voxels were determined by interpolation of shift vectors of VOIs, and then the previous CT image was nonlinearly warped according to the shift vector for each voxel. Finally, the warped previous CT image was subtracted from the current CT image. The 3D temporal subtraction method was applied to 19 clinical cases. The normal background structures such as vessels, ribs, and heart were removed without large misregistration artifacts. Thus, interval changes due to lung diseases were clearly enhanced as white shadows on subtraction CT images.
Batchelor, Connor; Pordeli, Pooneh; d'Esterre, Christopher D; Najm, Mohamed; Al-Ajlan, Fahad S; Boesen, Mari E; McDougall, Connor; Hur, Lisa; Fainardi, Enrico; Shankar, Jai Jai Shiva; Rubiera, Marta; Khaw, Alexander V; Hill, Michael D; Demchuk, Andrew M; Sajobi, Tolulope T; Goyal, Mayank; Lee, Ting-Yim; Aviv, Richard I; Menon, Bijoy K
2017-06-01
Intracerebral hemorrhage is a feared complication of intravenous alteplase therapy in patients with acute ischemic stroke. We explore the use of multimodal computed tomography in predicting this complication. All patients were administered intravenous alteplase with/without intra-arterial therapy. An age- and sex-matched case-control design with classic and conditional logistic regression techniques was chosen for analyses. Outcome was parenchymal hemorrhage on 24- to 48-hour imaging. Exposure variables were imaging (noncontrast computed tomography hypoattenuation degree, relative volume of very low cerebral blood volume, relative volume of cerebral blood flow ≤7 mL/min·per 100 g, relative volume of T max ≥16 s with all volumes standardized to z axis coverage, mean permeability surface area product values within T max ≥8 s volume, and mean permeability surface area product values within ipsilesional hemisphere) and clinical variables (NIHSS [National Institutes of Health Stroke Scale], onset to imaging time, baseline systolic blood pressure, blood glucose, serum creatinine, treatment type, and reperfusion status). One-hundred eighteen subjects (22 patients with parenchymal hemorrhage versus 96 without, median baseline NIHSS score of 15) were included in the final analysis. In multivariable regression, noncontrast computed tomography hypoattenuation grade ( P <0.006) and computerized tomography perfusion white matter relative volume of very low cerebral blood volume ( P =0.04) were the only significant variables associated with parenchymal hemorrhage on follow-up imaging (area under the curve, 0.73; 95% confidence interval, 0.63-0.83). Interrater reliability for noncontrast computed tomography hypoattenuation grade was moderate (κ=0.6). Baseline hypoattenuation on noncontrast computed tomography and very low cerebral blood volume on computerized tomography perfusion are associated with development of parenchymal hemorrhage in patients with acute ischemic stroke receiving intravenous alteplase. © 2017 American Heart Association, Inc.
Yamashiro, Keisuke; Nakano, Makoto; Sawaki, Koichi; Okazaki, Fumihiko; Hirata, Yasuhisa; Takashiba, Shogo
2016-08-01
It is sometimes difficult to determine during the preoperative period whether patients have oral infections; these patients need treatment to prevent oral infection-related complications from arising during medical therapies, such as cancer therapy and surgery. One of the reasons for this difficulty is that basic medical tests do not identify oral infections, including periodontitis and periapical periodontitis. In this report, we investigated the potential of positron emission tomography/computerized tomography (PET/CT) as a diagnostic tool in these patients. We evaluated eight patients during the preoperative period. All patients underwent PET/CT scanning and were identified as having the signs of oral infection, as evidenced by (18)F-fludeoxyglucose (FDG) localization in the oral regions. Periodontal examination and orthopantomogram evaluation showed severe infection or bone resorption in the oral regions. (18)F-FDG was localized in oral lesions, such as severe periodontitis, apical periodontitis, and pericoronitis of the third molar. The densities of (18)F-FDG were proportional to the degree of inflammation. PET/CT is a potential diagnostic tool for oral infections. It may be particularly useful in patients during preoperative staging, as they frequently undergo scanning at this time, and those identified as having oral infections at this time require treatment before cancer therapy or surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leter, Edward M.; Cademartiri, Filippo; Levendag, Peter C.
2005-07-01
Purpose: We used four-dimensional multislice spiral computed tomography (MSCT) to determine respiratory lung-tumor motion and compared this strategy to common clinical practice in conformal radiotherapy treatment-planning imaging. Methods and Materials: The entire lung volume of 10 consecutive patients with 14 lung metastases were scanned by a 16-slice MSCT. During the scans, patients were instructed to breathe through a spirometer that was connected to a laptop computer. For each patient, 10 stacks of 1.5-mm slices, equally distributed throughout the respiratory cycle, were reconstructed from the acquired MSCT data. The lung tumors were manually contoured in each data set. For each patient,more » the tumor-volume contours of all data sets were copied to 1 data set, which allowed determination of the volume that encompassed all 10 lung-tumor positions (i.e., the tumor-traversed volume [TTV]) during the respiratory cycle. The TTV was compared with the 10 tumor volumes contoured for each patient, to which an empiric respiratory-motion margin was added. The latter target volumes were designated internal-motion included tumor volume (IMITV). Results: The TTV measurements were significantly smaller than the reference IMITV measurements (5.2 {+-} 10.2 cm{sup 3} and 10.1 {+-} 13.7 cm{sup 3}, respectively). All 10 IMITVs for 2 of the 4 tumors in 1 subject completely encompassed the TTV. All 10 IMITVs for 3 tumors in 2 patients did not show overlap with up to 35% of the corresponding TTV. The 10 IMITVs for the remaining tumors either completely encompassed the corresponding TTV or did not show overlap with up to 26% of the corresponding TTV. Conclusions: We found that individualized determination of respiratory lung-tumor motion by four-dimensional respiratory-gated MSCT represents a better and simple strategy to incorporate periodic physiologic motion compared with a generalized approach. The former strategy can, therefore, improve common and state-of-the-art clinical practice in conformal radiotherapy.« less
Van Mieghem, Carlos A G; Cademartiri, Filippo; Mollet, Nico R; Malagutti, Patrizia; Valgimigli, Marco; Meijboom, Willem B; Pugliese, Francesca; McFadden, Eugene P; Ligthart, Jurgen; Runza, Giuseppe; Bruining, Nico; Smits, Pieter C; Regar, Evelyn; van der Giessen, Willem J; Sianos, Georgios; van Domburg, Ron; de Jaegere, Peter; Krestin, Gabriel P; Serruys, Patrick W; de Feyter, Pim J
2006-08-15
Surveillance conventional coronary angiography (CCA) is recommended 2 to 6 months after stent-supported left main coronary artery (LMCA) percutaneous coronary intervention due to the unpredictable occurrence of in-stent restenosis (ISR), with its attendant risks. Multislice computed tomography (MSCT) is a promising technique for noninvasive coronary evaluation. We evaluated the diagnostic performance of high-resolution MSCT to detect ISR after stenting of the LMCA. Seventy-four patients were prospectively identified from a consecutive patient population scheduled for follow-up CCA after LMCA stenting and underwent MSCT before CCA. Until August 2004, a 16-slice scanner was used (n = 27), but we switched to the 64-slice scanner after that period (n = 43). Patients with initial heart rates > 65 bpm received beta-blockers, which resulted in a mean periscan heart rate of 57 +/- 7 bpm. Among patients with technically adequate scans (n = 70), MSCT correctly identified all patients with ISR (10 of 70) but misclassified 5 patients without ISR (false-positives). Overall, the accuracy of MSCT for detection of angiographic ISR was 93%. The sensitivity, specificity, and positive and negative predictive values were 100%, 91%, 67%, and 100%, respectively. When analysis was restricted to patients with stenting of the LMCA with or without extension into a single major side branch, accuracy was 98%. When both branches of the LMCA bifurcation were stented, accuracy was 83%. For the assessment of stent diameter and area, MSCT showed good correlation with intravascular ultrasound (r = 0.78 and 0.73, respectively). An intravascular ultrasound threshold value > or = 1 mm was identified to reliably detect in-stent neointima hyperplasia with MSCT. Current MSCT technology, in combination with optimal heart rate control, allows reliable noninvasive evaluation of selected patients after LMCA stenting. MSCT is safe to exclude left main ISR and may therefore be an acceptable first-line alternative to CCA.
Neurologic applications of positron emission tomography.
Lenzi, G L; Pantano, P
1984-11-01
The impact of computerized neuroimaging in the neurologic sciences has been so dramatic that it has completely changed our approach to the individual patient. Further changes may be expected from the newborn positron emission tomography (PET) and nuclear magnetic resonance (NMR) in order to help the reader digest a large bulk of data and fully realize the present state of the art of PET, the authors have shaped this review mainly on results rather than on methods and on published reports rather than on future potential.
McClellan, Taylor; Allen, Brian C; Kappus, Matthew; Bhatti, Lubna; Dafalla, Randa A; Snyder, Laurie D; Bashir, Mustafa R
To determine interreader and intrareader repeatability and correlations among measurements of computerized tomography-based anthropomorphic measurements in patients with pulmonary fibrosis undergoing lung transplantation. This was an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study of 23 randomly selected subjects (19 male and 4 female; median age = 69 years; range: 66-77 years) with idiopathic pulmonary fibrosis undergoing pulmonary transplantation, who had also undergone preoperative thoracoabdominal computerized tomography. Five readers of varying imaging experience independently performed the following cross-sectional area measurements at the inferior endplate of the L3 vertebral body: right and left psoas muscles, right and left paraspinal muscles, total abdominal musculature, and visceral and subcutaneous fat. The following measurements were obtained at the inferior endplate of T6: right and left paraspinal muscles with and without including the trapezius muscles and subcutaneous fat. Three readers repeated all measurements to assess intrareader repeatability. Intrareader repeatability was nearly perfect (interclass correlation coefficients = 0.99, P < 0.001). Interreader agreement was excellent across all 5 readers (interclass correlation coefficients: 0.71-0.99, P < 0.001). Coefficients of variance between measures ranged from 3.2%-6.8% for abdominal measurements, but were higher for thoracic measurements, up to 23.9%. Correlation between total paraspinal and total psoas muscle area was strong (r 2 = 0.67, P < 0.001). Thoracic and abdominal musculature had a weaker correlation (r 2 = 0.35-0.38, P < 0.001). Measures of thoracic and abdominal muscle and fat area are highly repeatable in patients with pulmonary fibrosis undergoing lung transplantation. Measures of muscle area are strongly correlated among abdominal locations, but inversely correlated between abdominal and thoracic locations. Copyright © 2017 Elsevier Inc. All rights reserved.
Renal calyceal anatomy characterization with 3-dimensional in vivo computerized tomography imaging.
Miller, Joe; Durack, Jeremy C; Sorensen, Mathew D; Wang, James H; Stoller, Marshall L
2013-02-01
Calyceal selection for percutaneous renal access is critical for safe, effective performance of percutaneous nephrolithotomy. Available anatomical evidence is contradictory and incomplete. We present detailed renal calyceal anatomy obtained from in vivo 3-dimentional computerized tomography renderings. A total of 60 computerized tomography urograms were randomly selected. The renal collecting system was isolated and 3-dimensional renderings were constructed. The primary plane of each calyceal group of 100 kidneys was determined. A coronal maximum intensity projection was used for simulated percutaneous access. The most inferior calyx was designated calyx 1. Moving superiorly, the subsequent calyces were designated calyx 2 and, when present, calyx 3. The surface rendering was rotated to assess the primary plane of the calyceal group and the orientation of the select calyx. The primary plane of the upper pole calyceal group was mediolateral in 95% of kidneys and the primary plane of the lower pole calyceal group was anteroposterior in 95%. Calyx 2 was chosen in 90 of 97 simulations and it was appropriate in 92%. Calyx 3 was chosen in 7 simulations but it was appropriate in only 57%. Calyx 1 was not selected in any simulation and it was anteriorly oriented in 75% of kidneys. Appropriate lower pole calyceal access can be reliably accomplished with an understanding of the anatomical relationship between individual calyceal orientation and the primary plane of the calyceal group. Calyx 2 is most often appropriate for accessing the anteroposterior primary plane of the lower pole. Calyx 1 is most commonly oriented anterior. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Childhood Psychosis and Computed Tomographic Brain Scan Findings.
ERIC Educational Resources Information Center
Gillberg, Christopher; Svendsen, Pal
1983-01-01
Computerized tomography (CT) of the brain was used to examine 27 infantile autistic children, 9 children with other kinds of childhood psychoses, 23 children with mental retardation, and 16 normal children. Gross abnormalities were seen in 26 percent of the autism cases. (Author/SEW)
Checking the possibility of controlling fuel element by X-ray computerized tomography
NASA Astrophysics Data System (ADS)
Trinh, V. B.; Zhong, Y.; Osipov, S. P.; Batranin, A. V.
2017-08-01
The article considers the possibility of checking fuel elements by X-ray computerized tomography. The checking tasks are based on the detection of particles of active material, evaluation of the heterogeneity of the distribution of uranium salts and the detection of clusters of uranium particles. First of all, scheme of scanning improve the performance and quality of the resulting three-dimensional images of the internal structure is determined. Further, the possibility of detecting clusters of uranium particles having the size of 1 mm3 and measuring the coordinates of clusters of uranium particles in the middle layer with the accuracy of within a voxel size (for the considered experiments of about 80 μm) is experimentally proved in the main part. The problem of estimating the heterogeneity of the distribution of the active material in the middle layer and the detection of particles of active material with a nominal diameter of 0.1 mm in the “blank” is solved.
Skeletal maturity assessment with the use of cone-beam computerized tomography.
Joshi, Vajendra; Yamaguchi, Tetsutaro; Matsuda, Yukiko; Kaneko, Norikazu; Maki, Kotarou; Okano, Tomohiro
2012-06-01
The aim of the study was to compare cervical vertebrae maturity assessed with the use of cone-beam computerized tomography (CBCT) with the hand-wrist maturation method and cervical vertebrae maturation assessed with the use of lateral cephalography for the assessment of skeletal maturity. Assessment of skeletal maturation was done using skeletal maturity indicators (SMI) from hand-wrist radiography, cervical vertebrae maturity index (CVMI) from CBCT and lateral cephalography (cephalo-CVMI). The Spearman correlation coefficient was used for statistical analysis. We observed a significant relationship between CBCT-CVMI and cephalo-CVMI as well as between CBCT-CVMI and SMI stages. The Spearman correlation coefficient value between CBCT-CVMI and cephalo-CVMI was 0.975 (P < .0001) and between CBCT-CVMI and SMI was 0.961(P < .0001). Cervical vertebrae maturity assessment with CBCT provided a reliable assessment of pubertal growth spurt, and therefore CBCT can be used to assess skeletal maturity. Copyright © 2012 Elsevier Inc. All rights reserved.
Kakimoto, Naoya; Chindasombatjaroen, Jira; Tomita, Seiki; Shimamoto, Hiroaki; Uchiyama, Yuka; Hasegawa, Yoko; Kishino, Mitsunobu; Murakami, Shumei; Furukawa, Souhei
2013-01-01
The purpose of this study was to investigate the usefulness of computerized tomography (CT), particularly contrast-enhanced CT, in differentiation of jaw cysts and cystic-appearing tumors. We retrospectively analyzed contrast-enhanced CT images of 90 patients with odontogenic jaw cysts or cystic-appearing tumors. The lesion size and CT values were measured and the short axis to long axis (S/L) ratio, contrast enhancement (CE) ratio, and standard deviation ratio were calculated. The lesion size and the S/L ratio of keratocystic odontogenic tumors were significantly different from those of radicular cysts and follicular cysts. There were no significant differences in the CE ratio among the lesions. Multidetector CT provided diagnostic information about the size of odontogenic cysts and cystic-appearing tumors of the jaws that was related to the lesion type, but showed no relation between CE ratio and the type of these lesions. Copyright © 2013 Elsevier Inc. All rights reserved.
Qu, Xing-min; Li, Gang; Ludlow, John B; Zhang, Zu-yan; Ma, Xu-chen
2010-12-01
The aim of this study was to compare effective doses resulting from different scan protocols for cone-beam computerized tomography (CBCT) using International Commission on Radiological Protection (ICRP) 1990 and 2007 calculations of dose. Average tissue-absorbed dose, equivalent dose, and effective dose for a ProMax 3D CBCT with different dental protocols were calculated using thermoluminescent dosimeter chips in a human equivalent phantom. Effective doses were derived using ICRP 1990 and the superseding 2007 recommendations. Effective doses (ICRP 2007) for default patient sizes from small to large ranged from 102 to 298 μSv. The coefficient of determination (R(2)) between tube current and effective dose (ICRP 2007) was 0.90. When scanning with lower resolution settings, the effective doses were reduced significantly (P < .05). ProMax 3D can provide a wide range of radiation dose levels. Reduction in radiation dose can be achieved when using lower settings of exposure parameters. Copyright © 2010 Mosby, Inc. All rights reserved.
An evaluation of the Meditech M250 and a comparison with other CT scanners.
Greensmith, R; Richardson, R B; Sargood, A J; Stevens, P H; Mackintosh, I P
1985-11-01
The Meditech M250 computerised tomography (CT) machine was evaluated during the first half of 1984. Measurements were made of noise, modulation transfer function, slice width, radiation dose profile, uniformity and linearity of CT number, effective photon energy and parameters relating to machine specification, such as pixel size and scan time. All breakdowns were logged to indicate machine reliability. A comparison with the established EMI CT1010 and CT5005 was made for noise, resolution and multislice radiation dose, as well as the dose efficiency or quality (Q) factor for both head and body modes of operation. The M250 was found to perform to its intended specification with an acceptable level of reliability.
[The clinical and X-ray classification of osteonecrosis of the low jaw].
Medvedev, Iu A; Basin, E M; Sokolina, I A
2013-01-01
To elaborate a clinical and X-ray classification of osteonecrosis of the low jaw in people with desomorphine or pervitin addiction. Ninety-two patients with drug addiction who had undergone orthopantomography, direct frontal X-ray of the skull, and multislice computed tomography, followed by multiplanar and three-dimensional imaging reconstruction were examined. One hundred thirty four X-ray films and 74 computed tomographic images were analyzed. The authors proposed a clinical and X-ray classification of osteonecrosis of the low jaw in people with desomorphine or pervitin addiction and elaborated recommendations for surgical interventions on the basis of the developed classification. The developed clinical and X-ray classification and recommendations for surgical interventions may be used to treat osteonecroses of various etiology.
Computed tomography angiography reveals the crime instrument – case report
Banaszek, Anna; Guziński, Maciej; Sąsiadek, Marek
2010-01-01
Summary Background: The development of multislice CT technology enabled imaging of post-traumatic brain lesions with isotropic resolution, which led to unexpected results in the presented case Case Report: An unconscious, 49-year-old male with a suspected trauma underwent a routine CT examination of the head, which revealed an unusual intracerebral bleeding and therefore was followed by CT angiography (CTA). The thorough analysis of CTA source scans led to the detection of the bleeding cause. Conclusions: The presented case showed that a careful analysis of a CT scan allows not only to define the extent of pathological lesions in the intracranial space but it also helps to detect the crime instrument, which is of medico-legal significance. PMID:22802784
Chae, Eun Jin; Goo, Hyun Woo; Kim, Seong-Chul; Yoon, Chong Hyun
2004-05-01
We report a symptomatic infant with very rare congenital arterioportal and portosystemic venous fistulae in the liver. Multislice CT after partial transcatheter embolisation revealed not only the complicated vascular architecture of the lesion, but also an incidental jejunal arteriovenous malformation which explained the patient's melena. The patient underwent ligation of the hepatic artery and resection of the jejunal arteriovenous malformation. Postoperative multislice CT clearly demonstrated the success of the treatment.
Linz, C; Müller-Richter, U D A; Buck, A K; Mottok, A; Ritter, C; Schneider, P; Metzen, D; Heuschmann, P; Malzahn, U; Kübler, A C; Herrmann, K; Bluemel, C
2015-01-01
Detecting bone invasion in oral cancer is crucial for therapy planning and the prognosis. The present study evaluated cone beam computed tomography (CBCT) for detecting bone invasion in comparison to standard imaging techniques. A total of 197 patients with diagnoses of oral cancer underwent CBCT as part of preoperative staging between January 2007 and April 2013. The sensitivity, specificity, and accuracy of CBCT were compared with panoramic radiography (PR), multi-slice computed tomography (CT) or magnetic resonance imaging (MRI), and bone scintigraphy (BS) using McNemar's test. Histopathology and clinical follow-up served as references for the presence of bone invasion. CBCT and BS (84.8% and 89.3%, respectively), as well as CBCT and CT/MRI (83.2%), showed comparable accuracy (P = 0.188 and P = 0.771). CBCT was significantly superior to PR, which was reconstructed based on a CBCT dataset (74.1%, P = 0.002). In detecting bone invasion, CBCT was significantly more accurate than PR and was comparable to BS and CT/MRI. However, each method has certain advantages, and the best combination of imaging methods must be evaluated in prospective clinic trials. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Rapid prototyping modelling in oral and maxillofacial surgery: A two year retrospective study.
Suomalainen, Anni; Stoor, Patricia; Mesimäki, Karri; Kontio, Risto K
2015-12-01
The use of rapid prototyping (RP) models in medicine to construct bony models is increasing. The aim of the study was to evaluate retrospectively the indication for the use of RP models in oral and maxillofacial surgery at Helsinki University Central Hospital during 2009-2010. Also, the used computed tomography (CT) examination - multislice CT (MSCT) or cone beam CT (CBCT) - method was evaluated. In total 114 RP models were fabricated for 102 patients. The mean age of the patients at the time of the production of the model was 50.4 years. The indications for the modelling included malignant lesions (29%), secondary reconstruction (25%), prosthodontic treatment (22%), orthognathic surgery or asymmetry (13%), benign lesions (8%), and TMJ disorders (4%). MSCT examination was used in 92 and CBCT examination in 22 cases. Most of the models (75%) were conventional hard tissue models. Models with colored tumour or other structure(s) of interest were ordered in 24%. Two out of the 114 models were soft tissue models. The main benefit of the models was in treatment planning and in connection with the production of pre-bent plates or custom made implants. The RP models both facilitate and improve treatment planning and intraoperative efficiency. Rapid prototyping, radiology, computed tomography, cone beam computed tomography.
Sarcoidosis Occurring After Solid Cancer: A Nonfortuitous Association
Grados, Aurélie; Ebbo, Mikael; Bernit, Emmanuelle; Veit, Véronique; Mazodier, Karin; Jean, Rodolphe; Coso, Diane; Aurran-Schleinitz, Thérèse; Broussais, Florence; Bouabdallah, Reda; Gravis, Gwenaelle; Goncalves, Anthony; Giovaninni, Marc; Sève, Pascal; Chetaille, Bruno; Gavet-Bongo, Florence; Weitten, Thierry; Pavic, Michel; Harlé, Jean-Robert; Schleinitz, Nicolas
2015-01-01
Abstract The association between cancer and sarcoidosis is controversial. Some epidemiological studies show an increase of the incidence of cancer in patients with sarcoidosis but only few cases of sarcoidosis following cancer treatment have been reported. We conducted a retrospective case study from internal medicine and oncology departments for patients presenting sarcoidosis after solid cancer treatment. We also performed a literature review to search for patients who developed sarcoidosis after solid cancer. We describe the clinical, biological, and radiological characteristics and outcome of these patients. Twelve patients were included in our study. Various cancers were observed with a predominance of breast cancer. Development of sarcoidosis appeared in the 3 years following cancer and was asymptomatic in half of the patients. The disease was frequently identified after a follow-up positron emission tomography computerized tomography evaluation. Various manifestations were observed but all patients presented lymph node involvement. Half of the patients required systemic therapy. With a median follow-up of 73 months, no patient developed cancer relapse. Review of the literature identified 61 other patients for which the characteristics of both solid cancer and sarcoidosis were similar to those observed in our series. This report demonstrates that sarcoidosis must be considered in the differential diagnosis of patients with a history of malignancy who have developed lymphadenopathy or other lesions on positron emission tomography computerized tomography. Histological confirmation of cancer relapse is mandatory in order to avoid unjustified treatments. This association should be consider as a protective factor against cancer relapse. PMID:26181571
The incidence of coronary anomalies on routine coronary computed tomography scans
Karabay, Kanber Ocal; Yildiz, Abdulmelik; Bagirtan, Bayram; Geceer, Gurkan; Uysal, Ender
2013-01-01
Summary Objective This study aimed to assess the incidence of coronary anomalies using 64-multi-slice coronary computed tomography (MSCT). Methods The diagnostic MSCT scans of 745 consecutive patients were reviewed. Results The incidence of coronary anomalies was 4.96%. The detected coronary anomalies included the conus artery originating separately from the right coronary sinus (RCS) (n = 8, 1.07%), absence of the left main artery (n = 7, 0.93%), a superior right coronary artery (RCA) (n = 7, 0.93%), the circumflex artery (CFX) arising from the RCS (n = 4, 0.53%), the CFX originating from the RCA (n = 2, 0.26%), a posterior RCA (n = 1, 0.13%), a coronary fistula from the left anterior descending artery and RCA to the pulmonary artery (n = 1, 0.13%), and a coronary aneurysm (n = 1, 0.13%). Conclusions This study indicated that MSCT can be used to detect common coronary anomalies, and shows it has the potential to aid cardiologists and cardiac surgeons by revealing the origin and course of the coronary vessels. PMID:24042853
Loeffler, Ralf B; McCarville, M Beth; Wagstaff, Anne W; Smeltzer, Matthew P; Krafft, Axel J; Song, Ruitian; Hankins, Jane S; Hillenbrand, Claudia M
2017-01-01
Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2* methods can be interchangeably used in existing R2*-HIC calibrations.
Cost-Effective and High-Resolution Subsurface Characterization Using Hydraulic Tomography
2017-08-28
implementation and compare costs associated with HT and conventional methods. TECHNOLOGY DESCRIPTION The HT concept is analogous to the Computerized...develop guidance for HT field implementation and compare costs associated with HT and conventional methods. 15. SUBJECT TERMS Subsurface...3 2.1 TECHNOLOGY DESCRIPTION
32 CFR Appendix A to Part 199 - Acronyms
Code of Federal Regulations, 2014 CFR
2014-07-01
... 199—Acronyms AFR—Air Force Regulation AR—Army Regulation ASD (HA)—Assistant Secretary of Defense... Renal Disease CT—Computerized Tomography DASD (A)—Deputy Assistant Secretary of Defense (Administration....—Licensed Practical Nurse L.V.N.—Licensed Vocational Nurse MBD—Minimal Brain Dysfunction MCO—Marine Corps...
32 CFR Appendix A to Part 199 - Acronyms
Code of Federal Regulations, 2013 CFR
2013-07-01
... 199—Acronyms AFR—Air Force Regulation AR—Army Regulation ASD (HA)—Assistant Secretary of Defense... Renal Disease CT—Computerized Tomography DASD (A)—Deputy Assistant Secretary of Defense (Administration....—Licensed Practical Nurse L.V.N.—Licensed Vocational Nurse MBD—Minimal Brain Dysfunction MCO—Marine Corps...
32 CFR Appendix A to Part 199 - Acronyms
Code of Federal Regulations, 2012 CFR
2012-07-01
... 199—Acronyms AFR—Air Force Regulation AR—Army Regulation ASD (HA)—Assistant Secretary of Defense... Renal Disease CT—Computerized Tomography DASD (A)—Deputy Assistant Secretary of Defense (Administration....—Licensed Practical Nurse L.V.N.—Licensed Vocational Nurse MBD—Minimal Brain Dysfunction MCO—Marine Corps...
Non-Invasive Visualization and Quantitation of Cardiovascular Structure and Function.
ERIC Educational Resources Information Center
Ritman, E. L.; And Others
1979-01-01
Described is a new approach to investigative physiology based on computerized transaxial tomography, in which visualization and measurement of the internal structure of the cardiopulmonary system is possible without postmortem, biopsy, or vivisection procedures. Examples are given for application of the Dynamic Spatial Reconstructor (DSR). (CS)
Classification algorithm of lung lobe for lung disease cases based on multislice CT images
NASA Astrophysics Data System (ADS)
Matsuhiro, M.; Kawata, Y.; Niki, N.; Nakano, Y.; Mishima, M.; Ohmatsu, H.; Tsuchida, T.; Eguchi, K.; Kaneko, M.; Moriyama, N.
2011-03-01
With the development of multi-slice CT technology, to obtain an accurate 3D image of lung field in a short time is possible. To support that, a lot of image processing methods need to be developed. In clinical setting for diagnosis of lung cancer, it is important to study and analyse lung structure. Therefore, classification of lung lobe provides useful information for lung cancer analysis. In this report, we describe algorithm which classify lungs into lung lobes for lung disease cases from multi-slice CT images. The classification algorithm of lung lobes is efficiently carried out using information of lung blood vessel, bronchus, and interlobar fissure. Applying the classification algorithms to multi-slice CT images of 20 normal cases and 5 lung disease cases, we demonstrate the usefulness of the proposed algorithms.
Bigler, E D
1999-08-01
Contemporary neuorimaging techniques in child traumatic brain injury are reviewed, with an emphasis on computerized tomography (CT) and magnetic resonance (MR) imaging. A brief overview of MR spectroscopy (MRS), functional MR imaging (fMRI), single-photon emission computed tomography (SPECT), and magnetoencephalography (MEG) is also provided because these techniques will likely constitute important neuroimaging techniques of the future. Numerous figures are provided to illustrate the multifaceted manner in which traumatic deficits can be imaged and the role of neuroimaging information as it relates to TBI outcome.
An extraction algorithm of pulmonary fissures from multislice CT image
NASA Astrophysics Data System (ADS)
Tachibana, Hiroyuki; Saita, Shinsuke; Yasutomo, Motokatsu; Kubo, Mitsuru; Kawata, Yoshiki; Niki, Noboru; Nakano, Yasutaka; Sasagawa, Michizo; Eguchi, Kenji; Moriyama, Noriyuki
2005-04-01
Aging and smoking history increases number of pulmonary emphysema. Alveoli restoration destroyed by pulmonary emphysema is difficult and early direction is important. Multi-slice CT technology has been improving 3-D image analysis with higher body axis resolution and shorter scan time. And low-dose high accuracy scanning becomes available. Multi-slice CT image helps physicians with accurate measuring but huge volume of the image data takes time and cost. This paper is intended for computer added emphysema region analysis and proves effectiveness of proposed algorithm.
Multislice CT urography: state of the art.
Noroozian, M; Cohan, R H; Caoili, E M; Cowan, N C; Ellis, J H
2004-01-01
Recent improvements in helical CT hardware and software have provided imagers with the tools to obtain an increasingly large number of very thin axial images. As a result, a number of new applications for multislice CT have recently been developed, one of which is CT urography. The motivation for performing CT urography is the desire to create a single imaging test that can completely assess the kidneys and urinary tract for urolithiasis, renal masses and mucosal abnormalities of the renal collecting system, ureters and bladder. Although the preferred technique for performing multislice CT urography has not yet been determined and results are preliminary, early indications suggest that this examination can detect even subtle benign and malignant urothelial abnormalities and that it has the potential to completely replace excretory urography within the next several years. An important limitation of multislice CT urography is increased patient radiation exposure encountered when some of the more thorough recommended techniques are utilized.
Sinogram restoration for ultra-low-dose x-ray multi-slice helical CT by nonparametric regression
NASA Astrophysics Data System (ADS)
Jiang, Lu; Siddiqui, Khan; Zhu, Bin; Tao, Yang; Siegel, Eliot
2007-03-01
During the last decade, x-ray computed tomography (CT) has been applied to screen large asymptomatic smoking and nonsmoking populations for early lung cancer detection. Because a larger population will be involved in such screening exams, more and more attention has been paid to studying low-dose, even ultra-low-dose x-ray CT. However, reducing CT radiation exposure will increase noise level in the sinogram, thereby degrading the quality of reconstructed CT images as well as causing more streak artifacts near the apices of the lung. Thus, how to reduce the noise levels and streak artifacts in the low-dose CT images is becoming a meaningful topic. Since multi-slice helical CT has replaced conventional stop-and-shoot CT in many clinical applications, this research mainly focused on the noise reduction issue in multi-slice helical CT. The experiment data were provided by Siemens SOMATOM Sensation 16-Slice helical CT. It included both conventional CT data acquired under 120 kvp voltage and 119 mA current and ultra-low-dose CT data acquired under 120 kvp and 10 mA protocols. All other settings are the same as that of conventional CT. In this paper, a nonparametric smoothing method with thin plate smoothing splines and the roughness penalty was proposed to restore the ultra-low-dose CT raw data. Each projection frame was firstly divided into blocks, and then the 2D data in each block was fitted to a thin-plate smoothing splines' surface via minimizing a roughness-penalized least squares objective function. By doing so, the noise in each ultra-low-dose CT projection was reduced by leveraging the information contained not only within each individual projection profile, but also among nearby profiles. Finally the restored ultra-low-dose projection data were fed into standard filtered back projection (FBP) algorithm to reconstruct CT images. The rebuilt results as well as the comparison between proposed approach and traditional method were given in the results and discussions section, and showed effectiveness of proposed thin-plate based nonparametric regression method.
Single coronary artery originating from the right sinus Valsalva and ability to work.
De Rosa, Roberto; Ratti, Gennaro; Gerardi, Donato; Tedeschi, Carlo; Lamberti, Monica
2015-01-01
We present a case of a 56-year-old male electrician who was admitted to the hospital with atrial fibrillation, atypical chest pain and dyspnea. He gave a history that on the morning he had working for almost 4 hours carrying out various activities with considerable physical effort. After cardioversion, conventional coronary angiography revealed a suspect of single coronary vessel (SCA) arising from the right sinus of Valsalva. The patient underwent multislice computed tomography that showed a SCA arising from the right sinus Valsalva and dividing in Right Coronary Artery (RCA) and Left Main coronary artery (LM). The finding of posterior course of the LM without atherosclerotic has proved crucial for the expression of an opinion of working capacity even with limitation.
Rare Forms of Castleman Disease Mimicking Malignancy: Mesenteric and Pancreatic Involvement.
Ozsoy, Mustafa; Ozsoy, Zehra; Sahin, Suleyman; Arıkan, Yuksel
2018-03-12
Castleman disease is a lymphoproliferative disorder with unknown etiology and pathogenesis. While the disease may involve all parts of the body, the mediastinum appears to be the most common part of involvement. In this study, we present two cases of Castleman disease with different localizations that mimicked malignancy. A 62-year-old female patient presented with jaundice. Laboratory analysis indicated aspartate aminotransferase: 250 U/L, total bilirubin: 4 mg/dl, and carbohydrate antigen (CA) 19-9: 900 U/ml. Computerized tomography (CT) of the abdomen showed a mass originating from the pancreas head which resulted in a biliary tract obstruction. A positron emission tomography-computed tomography (PET/CT) showed that the only site of involvement was the pancreas head. A decision was made to perform pancreaticoduodenectomy. During intra-abdominal exploration, lymphadenopathies were identified in the surroundings of the retropancreatic portal vein and the hepatic artery. Histopathological investigation of the dissected lymph nodes demonstrated findings consistent with granulomatous plasma-cell-rich Castleman disease. A 55-year-old female patient presented with abdominal pain, nausea, and vomiting. Computerized tomography of the abdomen showed an abdominal mass of 7 cm, originating from the mesenterium, with high-contrast uptake in the mesenterium in the lower abdominal quadrant. The mesenteric mass was resected along with segmentary small intestine resection. Histopathological investigation of the mass showed a giant granulomatous structure that consisted of plasma cells consistent with Castleman disease. Castleman disease should be kept in mind during differential diagnosis of locally advanced lymph nodes observed during preoperative investigations and intraoperative exploration.
Robust Spatial Autoregressive Modeling for Hardwood Log Inspection
Dongping Zhu; A.A. Beex
1994-01-01
We explore the application of a stochastic texture modeling method toward a machine vision system for log inspection in the forest products industry. This machine vision system uses computerized tomography (CT) imaging to locate and identify internal defects in hardwood logs. The application of CT to such industrial vision problems requires efficient and robust image...
Letter to the Editor: Use of Publicly Available Image Resources
Armato, Samuel G.; Drukker, Karen; Li, Feng; ...
2017-05-11
Here we write with regard to the Academic Radiology article entitled, “Computer-aided Diagnosis for Lung Cancer: Usefulness of Nodule Heterogeneity” by Drs. Nishio and Nagashima (1). The authors also report on a computerized method to classify as benign or malignant lung nodules present in computed tomography (CT) scans.
FOUNTOULAKIS, E.N.; PAPADAKI, E.; PANAGIOTAKI, I.; GIANNIKAKI, E.; LAGOUDIANAKIS, G.; BIZAKIS, J.
2011-01-01
SUMMARY Haemangiopericytoma is a rare soft tissue tumour, with great histological variability and unpredictable clinical and biological behaviour. The precise cell type origin is uncertain. One third of haemangiopericytomas occur in the head and neck area, but only a few cases have been reported regarding localization at the parapharyngeal space. Herewith, case is presented of a 54-year-old female, referred to our Department due to a parapharyngeal space tumour with non-specific imaging characteristics. The patient underwent radical excision of the tumour with a trans-cervical sub-mandibular approach. The histolopathologic examination revealed a neoplasm with the characteristic features of haemangiopericytoma. One year later, during the scheduled follow-up, the computerized tomography scan showed no evidence of recurrence or residual disease. The pre-operative evaluation of a haemangiopericytoma must include a thorough imaging evaluation with computerized tomography and magnetic resonance imaging, even if results may not be specific for haemangiopericytoma. Angiography and pre-operative embolization may be performed in cases of large tumours with significant vascularity. The treatment of choice is radical excision. The follow-up includes clinical evaluation every 6 months and annual magnetic resonance imaging for at least 3 years. PMID:22058597
Application of Micromirror in Microsurgical Clipping to the Intracranial Aneurysms.
Zhao, Chao; Ma, Zhiguo; Zhang, Yuhai; Mou, Shanling; Yang, Yunxue; Yang, Yonglin; Sun, Guoqing; Yao, Weicheng
2018-05-01
The aim of the study was to explore the values and disadvantages of micromirror in the intracranial aneurysm clipping surgery. Micromirror was used to assist microsurgical clipping to 36 intracranial aneurysms in 31 patients, of which 3 were carotid-ophthalmic artery aneurysms, 3 were anterior choroidal artery aneurysms, 11 were posterior communicating artery aneurysms, 7 were middle cerebral artery aneurysms, 10 were anterior communicating artery or anterior cerebral artery aneurysms, and the rest were a posterior cerebral artery aneurysm and a posterior inferior cerebellar artery aneurysm. The micromirror was used before and after clipping to observe the anatomic features of necks hidden behind and medial to aneurysms, to visualize surrounding neurovascular structures, and to verify the optimal clipping position. Intraoperative indocyanine green fluorescein angiography, postoperative computerized tomography angiography, and digital subtraction angiography confirmed the success of sufficient clipping. Intraoperative indocyanine green angiography, postoperative computerized tomography angiography , or digital subtraction angiography were performed and showed no case of wrong or insufficient clipping of aneurysm. Micromirror-assisted microsurgical clipping to the intracranial aneurysm is safe, sufficient, convenient, and practical.
Li, Heheng; Luo, Liangping; Huang, Li
2011-02-01
The present paper is aimed to study the fractal spectrum of the cerebral computerized tomography in 158 normal infants of different age groups, based on the calculation of chaotic theory. The distribution range of neonatal period was 1.88-1.90 (mean = 1.8913 +/- 0.0064); It reached a stable condition at the level of 1.89-1.90 during 1-12 months old (mean = 1.8927 +/- 0.0045); The normal range of 1-2 years old infants was 1.86-1.90 (mean = 1.8863 +/- 4 0.0085); It kept the invariance of the quantitative value among 1.88-1.91(mean = 1.8958 +/- 0.0083) during 2-3 years of age. ANOVA indicated there's no significant difference between boys and girls (F = 0.243, P > 0.05), but the difference of age groups was significant (F = 8.947, P < 0.001). The fractal dimension of cerebral computerized tomography in normal infants computed by box methods was maintained at an efficient stability from 1.86 to 1.91. It indicated that there exit some attractor modes in pediatric brain development.
Jiang, Baofeng; Jia, Pengjiao; Zhao, Wen; Wang, Wentao
2018-01-01
This paper explores a new method for rapid structural damage inspection of steel tube slab (STS) structures along randomly measured paths based on a combination of compressive sampling (CS) and ultrasonic computerized tomography (UCT). In the measurement stage, using fewer randomly selected paths rather than the whole measurement net is proposed to detect the underlying damage of a concrete-filled steel tube. In the imaging stage, the ℓ1-minimization algorithm is employed to recover the information of the microstructures based on the measurement data related to the internal situation of the STS structure. A numerical concrete tube model, with the various level of damage, was studied to demonstrate the performance of the rapid UCT technique. Real-world concrete-filled steel tubes in the Shenyang Metro stations were detected using the proposed UCT technique in a CS framework. Both the numerical and experimental results show the rapid UCT technique has the capability of damage detection in an STS structure with a high level of accuracy and with fewer required measurements, which is more convenient and efficient than the traditional UCT technique.
Wang, Xi-ming; Wu, Le-bin; Zhang, Yun-ting; Li, Zhen-jia; Liu, Chen
2006-11-01
To discuss the value of multi-slice CT dynamic enhancement scan in the diagnosis and treatment of colonic lymphomas. 16 patients with colonic lymphomas underwent multi-slice CT dynamic enhancement scans, images of axial and reconstructive images of VR, MPR and CTVE were analyzed, patients were respectively diagnosed. Appearances of primary colorectal lymphomas were categorized into focal and diffuse lesions. Focal and diffuse lesions were 6 and 10 patients, respectively. The accuracy rate of diagnosis was 87.5%. MSCT dynamic scan has distinctive superiority in diagnosis and treatment of colonic lymphomas.
Rapid prototyping modelling in oral and maxillofacial surgery: A two year retrospective study
Stoor, Patricia; Mesimäki, Karri; Kontio, Risto K.
2015-01-01
Background The use of rapid prototyping (RP) models in medicine to construct bony models is increasing. Material and Methods The aim of the study was to evaluate retrospectively the indication for the use of RP models in oral and maxillofacial surgery at Helsinki University Central Hospital during 2009-2010. Also, the used computed tomography (CT) examination – multislice CT (MSCT) or cone beam CT (CBCT) - method was evaluated. Results In total 114 RP models were fabricated for 102 patients. The mean age of the patients at the time of the production of the model was 50.4 years. The indications for the modelling included malignant lesions (29%), secondary reconstruction (25%), prosthodontic treatment (22%), orthognathic surgery or asymmetry (13%), benign lesions (8%), and TMJ disorders (4%). MSCT examination was used in 92 and CBCT examination in 22 cases. Most of the models (75%) were conventional hard tissue models. Models with colored tumour or other structure(s) of interest were ordered in 24%. Two out of the 114 models were soft tissue models. Conclusions The main benefit of the models was in treatment planning and in connection with the production of pre-bent plates or custom made implants. The RP models both facilitate and improve treatment planning and intraoperative efficiency. Key words:Rapid prototyping, radiology, computed tomography, cone beam computed tomography. PMID:26644837
Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.
Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; van der Stelt, Paul; Wismeijer, Daniel
2015-01-01
The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P < 0.001) except for mean measurement between CBCT BV/TV and micro-CT BV/TV (P = 0.147). An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Langer, Christoph; Schroeder, Janina; Peterschroeder, Andreas; Vaske, Bernhard; Faber, Lothar; Welge, Dirk; Niethammer, Matthias; Lamp, Barbara; Butz, Thomas; Bitter, Thomas; Oldenburg, Olaf; Horstkotte, Dieter
2010-07-01
Multi-slice computed tomography (MSCT) was proved to provide precise cardiac volumetric assessment. Cardiac resynchronization therapy (CRT) is an effective treatment for selected patients with heart failure and reduced ejection fraction (HFREF). In HFREF patients we investigated the potential of MSCT based wall motion analysis in order to demonstrate CRT-induced reversed remodeling. Besides six patients with normal cardiac pump function serving as control group seven HFREF patients underwent contrast enhanced MSCT before and after CRT. Short cardiac axis views of the left ventricle (LV) in end-diastole (ED) and end-systole (ES) served for planimetry. Pre- and post-CRT MSCT based volumetry was compared with 2D echo. To demonstrate CRT-induced reverse remodeling, MSCT based multi-segment color-coded polar maps were introduced. With regard to the HFREF patients pre-CRT MSCT based volumetry correlated with 2D echo data for LV-EDV (MSCT 278.3+/-75.0mL vs. echo 274.4+/-85.6mL) r=0.380, p=0.401, LV-ESV (MSCT 226.7+/-75.4mL vs. echo 220.1+/-74.0mL) r=0.323, p=0.479 and LV-EF (MSCT 20.2+/-8.8% vs. echo 20.0+/-11.9%) r=0.617, p=0.143. Post-CRT MSCT correlated well with 2D echo: LV-EDV (MSCT 218.9+/-106.4mL vs. echo 188.7+/-93.1mL) r=0.87, p=0.011, LV-ESV (MSCT 145+/-71.5mL vs. echo 125.6+/-78mL) r=0.84, p=0.018 and LV-EF (MSCT 29.6+/-11.3mL vs. echo 38.6+/-14.6mL) r=0.89, p=0.007. There was a significant increase of the mid-ventricular septum in terms of absolute LV wall thickening of the responders (pre 0.9+/-2.1mm vs. post 3.3+/-2.2mm; p<0.0005). MSCT based volumetry involving multi-segment color-coded polar maps offers wall motion analysis to demonstrate CRT-induced reverse remodeling which needs to be further validated. 2010 Elsevier Ltd. All rights reserved.
Processing And Display Of Medical Three Dimensional Arrays Of Numerical Data Using Octree Encoding
NASA Astrophysics Data System (ADS)
Amans, Jean-Louis; Darier, Pierre
1986-05-01
imaging modalities such as X-Ray computerized Tomography (CT), Nuclear Medecine and Nuclear Magnetic Resonance can produce three-dimensional (3-D) arrays of numerical data of medical object internal structures. The analysis of 3-D data by synthetic generation of realistic images is an important area of computer graphics and imaging.
Is the cervical spine clear? Undetected cervical fractures diagnosed only at autopsy.
Sweeney, J F; Rosemurgy, A S; Gill, S; Albrink, M H
1992-10-01
Undetected cervical-spine injuries are a nemesis to both trauma surgeons and emergency physicians. Radiographic protocols have been developed to avoid missing cervical-spine fractures but are not fail-safe. Three case reports of occult cervical fractures documented at autopsy in the face of normal cervical-spine radiographs and computerized tomography scans are presented.
[Two cases of severe eye and cranial injuries due to firework explosions].
Saunte, J P; Trojaborg, N S; Nielsen, O A; Thygesen, J
1999-12-20
Two patients who sustained serious facial, cranial and eye trauma secondary to recreational fireworks injuries are reported. Initial assessment included axial and coronary computerized tomography, control of haemorrhage, debridement of wound and brain, and in one patient bilateral excenteration of the globe. Both patients suffered from intracranial haemorrhage, but both recovered without severe neurological sequelae.
The New Approach to Sport Medicine: 3-D Reconstruction
ERIC Educational Resources Information Center
Ince, Alparslan
2015-01-01
The aim of this study is to present a new approach to sport medicine. Comparative analysis of the Vertebrae Lumbales was done in sedentary group and Muay Thai athletes. It was done by acquiring three dimensional (3-D) data and models through photogrammetric methods from the Multi-detector Computerized Tomography (MDCT) images of the Vertebrae…
Ultralow Dose MSCT Imaging in Dental Implantology
Widmann, Gerlig; Al-Ekrish, Asma'a A.
2018-01-01
Introduction: The Council Directive 2013/59 Euratom has a clear commitment for keeping medical radiation exposure as low as reasonably achievable and demands a regular review and use of diagnostic reference levels. Methods: In dental implantology, the range of effective doses for cone beam computed tomography (CBCT) shows a broad overlap with multislice computed tomography (MSCT). More recently, ultralow dose imaging with new generations of MSCT scanners may impart radiation doses equal to or lower than CBCT. Dose reductions in MSCT have been further facilitated by the introduction of iterative image reconstruction technology (IRT), which provides substantial noise reduction over the current standard of filtered backward projection (FBP). Aim: The aim of this article is to review the available literature on ultralow dose CT imaging and IRTs in dental implantology imaging and to summarize their influence on spatial and contrast resolution, image noise, tissue density measurements, and validity of linear measurements of the jaws. Conclusion: Application of ultralow dose MSCT with IRT technology in dental implantology offers the potential for very large dose reductions compared with standard dose imaging. Yet, evaluation of various diagnostic tasks related to dental implantology is still needed to confirm the results obtained with various IRTs and ultra-low doses so far. PMID:29492174
[Radiodiagnostic methods for dental anomalities].
Ternovoĭ, S K; Serova, N S; Ivanova, D V
2012-01-01
To determine the capacities of radiologic studies in the examination of patients with dental anomalies. One hundred and twenty patients with dental anomalies were examined. Conventional X-ray and high-technology radiology techniques (multislice spiral computed tomography (MSSCT) and cone-beam computed tomography (CBCT)) were used. Orthopantomography is the most common method for radiologic examination of patients with dental anomalies. However, X-ray procedures do not provide complete information on the position and status of an abnormal tooth, which is required to define further patient management tactics. While planning the management, MSSCT and CBCT were performed in 56 (46.7%) and 64 (53.3%) patients, respectively. In addition, 72 (60.0%) patients in whom orthodontic treatment had been recommended at the first stage underwent MSSCT or CBCT following 7 months. CBCT showed that 4 (3.3%) patients had dental ankylosis previously undiagnosed by MSSCT. The high-technology radiology techniques could assess the position of a tooth in relation to its important anatomic structures and identify the comorbidity that keeps from being treated. MSSCT and CBCT can make in full measure the topical diagnosis of abnormal teeth and hence choose an optimal algorithm for comprehensive treatment of patients.
Cocchia, Rosangela; D’Andrea, Antonello; Conte, Marianna; Cavallaro, Massimo; Riegler, Lucia; Citro, Rodolfo; Sirignano, Cesare; Imbriaco, Massimo; Cappelli, Maurizio; Gregorio, Giovanni; Calabrò, Raffaele; Bossone, Eduardo
2017-01-01
Transcatheter aortic valve replacement (TAVR) has been validated as a new therapy for patients affected by severe symptomatic aortic stenosis who are not eligible for surgical intervention because of major contraindication or high operative risk. Patient selection for TAVR should be based not only on accurate assessment of aortic stenosis morphology, but also on several clinical and functional data. Multi-Imaging modalities should be preferred for assessing the anatomy and the dimensions of the aortic valve and annulus before TAVR. Ultrasounds represent the first line tool in evaluation of this patients giving detailed anatomic description of aortic valve complex and allowing estimating with enough reliability the hemodynamic entity of valvular stenosis. Angiography should be used to assess coronary involvement and plan a revascularization strategy before the implant. Multislice computed tomography play a central role as it can give anatomical details in order to choice the best fitting prosthesis, evaluate the morphology of the access path and detect other relevant comorbidities. Cardiovascular magnetic resonance and positron emission tomography are emergent modality helpful in aortic stenosis evaluation. The aim of this review is to give an overview on TAVR clinical and technical aspects essential for adequate selection. PMID:28400918
Shu, Ting; Zhang, Bob; Tang, Yuan Yan
2017-01-01
At present, heart disease is the number one cause of death worldwide. Traditionally, heart disease is commonly detected using blood tests, electrocardiogram, cardiac computerized tomography scan, cardiac magnetic resonance imaging, and so on. However, these traditional diagnostic methods are time consuming and/or invasive. In this paper, we propose an effective noninvasive computerized method based on facial images to quantitatively detect heart disease. Specifically, facial key block color features are extracted from facial images and analyzed using the Probabilistic Collaborative Representation Based Classifier. The idea of facial key block color analysis is founded in Traditional Chinese Medicine. A new dataset consisting of 581 heart disease and 581 healthy samples was experimented by the proposed method. In order to optimize the Probabilistic Collaborative Representation Based Classifier, an analysis of its parameters was performed. According to the experimental results, the proposed method obtains the highest accuracy compared with other classifiers and is proven to be effective at heart disease detection.
A Case of an Upper Gastrointestinal Bleeding Due to a Ruptured Dissection of a Right Aortic Arch
DOE Office of Scientific and Technical Information (OSTI.GOV)
Born, Christine; Forster, Andreas; Rock, Clemens
2003-09-15
We report a case of severe upper gastrointestinal hemorrhage with a rare underlying cause. The patient was unconscious when he was admitted to the hospital. No chest radiogram was performed. Routine diagnostic measures, including endoscopy, failed to reveal the origin of the bleeding, which was believed to originate from the esophagus secondary to a peptic ulcer or varices. Exploratory laparotomy added no further information, but contrast-enhanced multislice computed tomography (MSCT) of the chest showed dextroposition of the widened aortic arch with a ruptured type-B dissection and a consecutive aorto-esophageal fistula (AEF). The patient died on the day of admission. Noninvasivemore » MSCT angiography gives rapid diagnostic information on patients with occult upper gastrointestinal bleeding and should be considered before more invasive conventional angiography or surgery.« less
NASA Astrophysics Data System (ADS)
Cushley, A. C.
2013-12-01
The proposed launch of a satellite carrying the first space-borne ADS-B receiver by the Royal Military College of Canada (RMCC) will create a unique opportunity to study the modification of the 1090 MHz radio waves following propagation through the ionosphere from the transmitting aircraft to the passive satellite receiver(s). Experimental work successfully demonstrated that ADS-B data can be used to reconstruct two dimensional (2D) electron density maps of the ionosphere using computerized tomography (CT). The goal of this work is to evaluate the feasibility of CT reconstruction. The data is modelled using Ray-tracing techniques. This allows us to determine the characteristics of individual waves, including the wave path and the state of polarization at the satellite receiver. The modelled Faraday rotation (FR) is determined and converted to total electron content (TEC) along the ray-paths. The resulting TEC is used as input for computerized ionospheric tomography (CIT) using algebraic reconstruction technique (ART). This study concentrated on meso-scale structures 100-1000 km in horizontal extent. The primary scientific interest of this thesis was to show the feasibility of a new method to image the ionosphere and obtain a better understanding of magneto-ionic wave propagation. Multiple feature input electron density profile to ray-tracing program. Top: reconstructed relative electron density map of ray-trace input (Fig. 1) using TEC measurements and line-of-sight path. Bottom: reconstructed electron density map of ray-trace input using quiet background a priori estimate.
Osteochondrosis of the inferior pole of the scapula (Roca disease).
Skaf, Abdalla; Taneja, Atul K
2014-03-01
We report a rare case of osteochondrosis of the inferior pole of the scapula in a 14-year-old boy, an amateur swimmer, that was diagnosed by a combination of clinical and imaging findings. Also known as Roca disease, this is the first article to report this entity in the English literature and demonstrates its computerized tomography and MRI features.
R. Edward Thomas
2013-01-01
Determining the defects located within a log is crucial to understanding the tree/log resource for efficient processing. However, existing means of doing this non-destructively requires the use of expensive x-ray/CT (computerized tomography), MRI (magnetic resonance imaging), or microwave technology. These methods do not lend themselves to fast, efficient, and cost-...
Jiang, Baofeng; Jia, Pengjiao; Zhao, Wen; Wang, Wentao
2018-01-01
This paper explores a new method for rapid structural damage inspection of steel tube slab (STS) structures along randomly measured paths based on a combination of compressive sampling (CS) and ultrasonic computerized tomography (UCT). In the measurement stage, using fewer randomly selected paths rather than the whole measurement net is proposed to detect the underlying damage of a concrete-filled steel tube. In the imaging stage, the ℓ1-minimization algorithm is employed to recover the information of the microstructures based on the measurement data related to the internal situation of the STS structure. A numerical concrete tube model, with the various level of damage, was studied to demonstrate the performance of the rapid UCT technique. Real-world concrete-filled steel tubes in the Shenyang Metro stations were detected using the proposed UCT technique in a CS framework. Both the numerical and experimental results show the rapid UCT technique has the capability of damage detection in an STS structure with a high level of accuracy and with fewer required measurements, which is more convenient and efficient than the traditional UCT technique. PMID:29293593
A Head and Neck Simulator for Radiology and Radiotherapy
NASA Astrophysics Data System (ADS)
Thompson, Larissa; Campos, Tarcísio P. R.
2013-06-01
Phantoms are suitable tools to simulate body tissues and organs in radiology and radiation therapy. This study presents the development of a physical head and neck phantom and its radiological response for simulating brain pathology. The following features on the phantom are addressed and compared to human data: mass density, chemical composition, anatomical shape, computerized tomography images and Hounsfield Units. Mass attenuation and kerma coefficients of the synthetic phantom and normal tissues, as well as their deviations, were also investigated. Radiological experiments were performed, including brain tumors and subarachnoid hemorrhage simulations. Computerized tomography images of such pathologies in phantom and human were obtained. The anthropometric dimensions of the phantom present anatomical conformation similar to a human head and neck. Elemental weight percentages of the equivalent tissues match the human ones. Hounsfield Unit values of the main developed structures are presented, approaching human data. Kerma and mass attenuation coefficients spectra from human and phantom are presented, demonstrating smaller deviations in the radiological X-ray spectral domain. In conclusion, the phantom presented suitable normal and pathological radiological responses relative to those observed in humans. It may improve radiological protocols and education in medical imaging.
Classification and Current Management of Inner Ear Malformations.
Sennaroğlu, Levent; Bajin, Münir Demir
2017-09-29
Morphologically congenital sensorineural hearing loss can be investigated under two categories. The majority of congenital hearing loss causes (80%) are membranous malformations. Here, the pathology involves inner ear hair cells. There is no gross bony abnormality and, therefore, in these cases high-resolution computerized tomography and magnetic resonance imaging of the temporal bone reveal normal findings. The remaining 20% have various malformations involving the bony labyrinth and, therefore, can be radiologically demonstrated by computerized tomography and magnetic resonance imaging. The latter group involves surgical challenges as well as problems in decision-making. Some cases may be managed by a hearing aid, others need cochlear implantation, and some cases are candidates for an auditory brainstem implantation (ABI). During cochlear implantation, there may be facial nerve abnormalities, cerebrospinal fluid leakage, electrode misplacement or difficulty in finding the cochlea itself. During surgery for inner ear malformations, the surgeon must be ready to modify the surgical approach or choose special electrodes for surgery. In the present review article, inner ear malformations are classified according to the differences observed in the cochlea. Hearing and language outcomes after various implantation methods are closely related to the status of the cochlear nerve, and a practical classification of the cochlear nerve deficiency is also provided.
Analysis of rocket beacon transmissions for computerized reconstruction of ionospheric densities
NASA Technical Reports Server (NTRS)
Bernhardt, P. A.; Huba, J. D.; Chaturvedi, P. K.; Fulford, J. A.; Forsyth, P. A.; Anderson, D. N.; Zalesak, S. T.
1993-01-01
Three methods are described to obtain ionospheric electron densities from transionospheric, rocket-beacon TEC data. First, when the line-of-sight from a ground receiver to the rocket beacon is tangent to the flight trajectory, the electron concentration can be obtained by differentiating the TEC with respect to the distance to the rocket. A similar method may be used to obtain the electron-density profile if the layer is horizontally stratified. Second, TEC data obtained during chemical release experiments may be interpreted with the aid of physical models of the disturbed ionosphere to yield spatial maps of the modified regions. Third, computerized tomography (CT) can be used to analyze TEC data obtained along a chain of ground-based receivers aligned along the plane of the rocket trajectory. CT analysis of TEC data is used to reconstruct a 2D image of a simulated equatorial plume. TEC data is computed for a linear chain of nine receivers with adjacent spacings of either 100 or 200 km. The simulation data are analyzed to provide an F region reconstruction on a grid with 15 x 15 km pixels. Ionospheric rocket tomography may also be applied to rocket-assisted measurements of amplitude and phase scintillations and airglow intensities.
Clinical technique for invasive cervical root resorption
Silveira, Luiz Fernando Machado; Silveira, Carina Folgearini; Martos, Josué; Piovesan, Edno Moacir; César Neto, João Batista
2011-01-01
This clinical case report describes the diagnosis and treatment of an external invasive cervical resorption. A 17-year-old female patient had a confirmed diagnosis of invasive cervical resorption class 4 by cone beam computerized tomography. Although, there was no communication with the root canal, the invasive resorption process was extending into the cervical and middle third of the root. The treatment of the cervical resorption of the lateral incisor interrupted the resorptive process and restored the damaged root surface and the dental functions without any esthetic sequelae. Both the radiographic examination and computed tomography are imperative to reveal the extent of the defect in the differential diagnosis. PMID:22144822
Amen, Daniel G; Hanks, Chris; Prunella, Jill R; Green, Aisa
2007-01-01
The authors explored differences in regional cerebral blood flow in 11 impulsive murderers and 11 healthy comparison subjects using single photon emission computed tomography. The authors assessed subjects at rest and during a computerized go/no-go concentration task. Using statistical parametric mapping software, the authors performed voxel-by-voxel t tests to assess significant differences, making family-wide error corrections for multiple comparisons. Murderers were found to have significantly lower relative rCBF during concentration, particularly in areas associated with concentration and impulse control. These results indicate that nonemotionally laden stimuli may result in frontotemporal dysregulation in people predisposed to impulsive violence.
Screening and Biosensor-Based Approaches for Lung Cancer Detection
Wang, Lulu
2017-01-01
Early diagnosis of lung cancer helps to reduce the cancer death rate significantly. Over the years, investigators worldwide have extensively investigated many screening modalities for lung cancer detection, including computerized tomography, chest X-ray, positron emission tomography, sputum cytology, magnetic resonance imaging and biopsy. However, these techniques are not suitable for patients with other pathologies. Developing a rapid and sensitive technique for early diagnosis of lung cancer is urgently needed. Biosensor-based techniques have been recently recommended as a rapid and cost-effective tool for early diagnosis of lung tumor markers. This paper reviews the recent development in screening and biosensor-based techniques for early lung cancer detection. PMID:29065541
Mobashsher, Ahmed Toaha; Abbosh, A M
2016-11-29
Rapid, on-the-spot diagnostic and monitoring systems are vital for the survival of patients with intracranial hematoma, as their conditions drastically deteriorate with time. To address the limited accessibility, high costs and static structure of currently used MRI and CT scanners, a portable non-invasive multi-slice microwave imaging system is presented for accurate 3D localization of hematoma inside human head. This diagnostic system provides fast data acquisition and imaging compared to the existing systems by means of a compact array of low-profile, unidirectional antennas with wideband operation. The 3D printed low-cost and portable system can be installed in an ambulance for rapid on-site diagnosis by paramedics. In this paper, the multi-slice head imaging system's operating principle is numerically analysed and experimentally validated on realistic head phantoms. Quantitative analyses demonstrate that the multi-slice head imaging system is able to generate better quality reconstructed images providing 70% higher average signal to clutter ratio, 25% enhanced maximum signal to clutter ratio and with around 60% hematoma target localization compared to the previous head imaging systems. Nevertheless, numerical and experimental results demonstrate that previous reported 2D imaging systems are vulnerable to localization error, which is overcome in the presented multi-slice 3D imaging system. The non-ionizing system, which uses safe levels of very low microwave power, is also tested on human subjects. Results of realistic phantom and subjects demonstrate the feasibility of the system in future preclinical trials.
Three-dimensional analysis of third molar development to estimate age of majority.
Márquez-Ruiz, Ana Belén; Treviño-Tijerina, María Concepción; González-Herrera, Lucas; Sánchez, Belén; González-Ramírez, Amanda Rocío; Valenzuela, Aurora
2017-09-01
Third molars are one of the few biological markers available for age estimation in undocumented juveniles close the legal age of majority, assuming an age of 18years as the most frequent legal demarcation between child and adult status. To obtain more accurate visualization and evaluation of third molar mineralization patterns from computed tomography images, a new software application, DentaVol©, was developed. Third molar mineralization according to qualitative (Demirjian's maturational stage) and quantitative parameters (third molar volume) of dental development was assessed in multi-slice helical computed tomography images of both maxillary arches displayed by DentaVol© from 135 individuals (62 females and 73 males) aged between 14 and 23years. Intra- and inter-observer agreement values were remarkably high for both evaluation procedures and for all third molars. A linear correlation between third molar mineralization and chronological age was found, with third molar maturity occurring earlier in males than in females. Assessment of dental development with both procedures, by using DentaVol© software, can be considered a good indicator of age of majority (18years or older) in all third molars. Our results indicated that virtual computed tomography imaging can be considered a valid alternative to orthopantomography for evaluations of third molar mineralization, and therefore a complementary tool for determining the age of majority. Copyright © 2017 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.
Imaging diagnostics: congenital malformations and acquired lesions of the inner ear.
Pont, Elena; Mazón, Miguel; Montesinos, Pau; Sánchez, Miguel Ángel; Más-Estellés, Fernando
2015-01-01
Congenital malformations and acquired lesions of the inner ear are characterised by small structural changes in this region. In recent decades, treatment options have improved considerably. At the same time, there has been a great advancement in diagnostic methods, obtaining high-resolution labyrinth images. Currently, we use a 64-multislice computed tomography scanner in spiral mode (Brilliance 64 Phillips, Eindhoven, the Netherlands), with an overlap of 0.66 mm and an interval of 0.33 mm, 120 KV and 300 mA. The magnetic resonance images were taken with Signa HDxt 1.5 and 3.0 T units (GE Healthcare, Waukesha, WI, USA). We reviewed the radiological features of the lesions affecting the inner ear. They are classified as congenital (labyrinth malformation and statoacoustic nerve deficiencies) or acquired (otospongiosis, labyrinthitis, Ménière's disease, inner ear haemorrhage, intralabyrinthine schwannoma and endolymphatic sac tumour). Magnetic resonance imaging and computed tomography play an essential role in diagnosing patients with inner ear pathology. The technique selected should be chosen depending on the clinical setting. In a generic way, tomography is the method of choice for the study of traumatic pathology or otospongiosis. When tumour or inflammatory pathology is suspected, magnetic resonance is superior. In cases of congenital malformation, both techniques are complementary. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.
Micro computed tomography features of laryngeal fractures in a case of fatal manual strangulation.
Fais, Paolo; Giraudo, Chiara; Viero, Alessia; Miotto, Diego; Bortolotti, Federica; Tagliaro, Franco; Montisci, Massimo; Cecchetto, Giovanni
2016-01-01
Cases of subtle fatal neck compression are often complicated by the lack of specificity of the post-mortem signs of asphyxia and by the lack of clear signs of neck compression. Herein we present a forensic case of a 45-year-old schizophrenic patient found on the floor of the bedroom of a psychiatric ward in cardiopulmonary arrest and who died after two days in a vegetative state. The deposition of the roommate of the deceased, who claimed responsibility for the killing of the victim by neck compression, was considered unreliable by the prosecutor. Autopsy, toxicological analyses, and multi-slice computed tomography (MSCT), micro computed tomography (micro-CT) and histology of the larynx complex were performed. Particularly, micro-CT analysis of the thyroid cartilage revealed the bilateral presence of ossified triticeous cartilages and the complete fragmentation of the right superior horn of the thyroid, but it additionally demonstrated a fracture on the contralateral superior horns, which was not clearly diagnosable at MSCT. On the basis of the evidence of intracartilaginous laryngeal hemorrhages and bilateral microfracture at the base of the superior horns of the larynx, the death was classified as a case of asphyxia due to manual strangulation. Micro-CT was confirmed as a useful tool in cases of subtle fatal neck compression, for the detection of minute laryngeal cartilage fractures, especially in complex cases with equivocal findings on MSCT. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Visualisation of the temporary cavity by computed tomography using contrast material.
Schyma, Christian; Hagemeier, Lars; Greschus, Susanne; Schild, Hans; Madea, Burkhard
2012-01-01
The temporary cavity of a missile produces radial tears in ordnance gelatine, which correlate to the energy transfer. Computed tomography is a useful and non-destructive method to examine gelatine blocks. However, the tears give only few radiocontrast by air filling, which decreases with the time past shooting. Therefore, systematically, a radiocontrast material was searched to enhance the contrast. Different contrast materials were amalgamated to acryl paint, and about 7 g was sealed in a foil bag, which was integrated in the front of a standard 10% gelatine cylinder. Shots with Action-5 expanding bullets were performed from a 5-m distance. Gelatine was scanned by multi-slice computed tomography. The multiplanar reconstructed images were compared to mechanically cut slices of 1 cm thickness. It was shown experimentally that iodine containing water-soluble contrast material did not give sufficient contrast and caused diffusion artefacts. Best results were obtained by barium sulphate emulsion. The amount of acryl paint was sufficient to colour the tears for optical scanning. The radiocontrast of barium leads to satisfying imaging of tears and allowed the creation of a three-dimensional reconstruction of the temporary cavity. Comparison of optical and radiological results showed an excellent correlation, but absolute measures in computed tomographic (CT) images remained lower compared with optically gathered values in the gelatine slices. Combination of paint and contrast material for CT examination will facilitate the evaluation of complex ballistic models and increase accuracy.
Kapanadze, L B; Ternovoy, S K; Rudenko, V I; Serova, N S
2018-03-01
Urolithiasis (urolithiasis) is one of the most common urologic diseases with an estimated prevalence of no less than 3% in the population, usually affecting active working-age patients of 30-50 years. Taking into account major public health and economic significance of this problem, there is the need for the development of effective modern diagnostic techniques. Rapid medical-technological advances of the past two decades have led to the wide spread use of minimally invasive surgery the management of urolithiasis. Nevertheless, surgical intervention only removes the result of a long pathological process and does not change its course. Thus, there is a need for a detailed understanding of the etiology, epidemiology, and pathogenesis of urolithiasis. Diagnostic imaging plays a key role in the diagnosis of urolithiasis. Multislice spiral computed tomography (MSCT) is the gold standard for the diagnosis of urolithiasis. It provides information about the size, location, and density of the calculus. Over the past decade, the use of dual-energy computed tomography (DECT) in urological practice has been widely discussed in the international and domestic literature. One of the main advantages of DECT is the ability to determine the chemical composition of urinary stones. Previous studies have reported a high diagnostic value of the method, including the ability to predict treatment outcomes. However, the shortcomings of the method and the absence of standardized examination protocols leave a wide field for further research. This article reviews major distinctive features of using DECT in the diagnosis of urolithiasis.
Gustorf, R
1979-07-01
Computer tomography enables exact diagnostic clarification of intracranial lesions in trauma of the neurocranium. Subdural or epidural as well as intracerebral haemorrhages can be localised, and a circumscribed contusion and cerebral oedema become tangible. The article reports on 90 patients subjected to computerized tomography following trauma of the neurocranium. In about 50% of the cases, the trauma had been caused by a traffic accident. About 27% of the accident victims were children and adolescents. In about one-half of the examined persons, subdural or epidural haemorrhages were found, whereas in about 20% of the cases, contusions, partly with mild haemorrhages, were seen. In about 10% of the cases a more or less severe oedema was seen. About 20% of the patients yielded no abnormal finding by CT in accordance with the age of the patient.
LUNGx Challenge for computerized lung nodule classification
Armato, Samuel G.; Drukker, Karen; Li, Feng; ...
2016-12-19
The purpose of this work is to describe the LUNGx Challenge for the computerized classification of lung nodules on diagnostic computed tomography (CT) scans as benign or malignant and report the performance of participants’ computerized methods along with that of six radiologists who participated in an observer study performing the same Challenge task on the same dataset. The Challenge provided sets of calibration and testing scans, established a performance assessment process, and created an infrastructure for case dissemination and result submission. We present ten groups that applied their own methods to 73 lung nodules (37 benign and 36 malignant) thatmore » were selected to achieve approximate size matching between the two cohorts. Area under the receiver operating characteristic curve (AUC) values for these methods ranged from 0.50 to 0.68; only three methods performed statistically better than random guessing. The radiologists’ AUC values ranged from 0.70 to 0.85; three radiologists performed statistically better than the best-performing computer method. The LUNGx Challenge compared the performance of computerized methods in the task of differentiating benign from malignant lung nodules on CT scans, placed in the context of the performance of radiologists on the same task. Lastly, the continued public availability of the Challenge cases will provide a valuable resource for the medical imaging research community.« less
LUNGx Challenge for computerized lung nodule classification
Armato, Samuel G.; Drukker, Karen; Li, Feng; Hadjiiski, Lubomir; Tourassi, Georgia D.; Engelmann, Roger M.; Giger, Maryellen L.; Redmond, George; Farahani, Keyvan; Kirby, Justin S.; Clarke, Laurence P.
2016-01-01
Abstract. The purpose of this work is to describe the LUNGx Challenge for the computerized classification of lung nodules on diagnostic computed tomography (CT) scans as benign or malignant and report the performance of participants’ computerized methods along with that of six radiologists who participated in an observer study performing the same Challenge task on the same dataset. The Challenge provided sets of calibration and testing scans, established a performance assessment process, and created an infrastructure for case dissemination and result submission. Ten groups applied their own methods to 73 lung nodules (37 benign and 36 malignant) that were selected to achieve approximate size matching between the two cohorts. Area under the receiver operating characteristic curve (AUC) values for these methods ranged from 0.50 to 0.68; only three methods performed statistically better than random guessing. The radiologists’ AUC values ranged from 0.70 to 0.85; three radiologists performed statistically better than the best-performing computer method. The LUNGx Challenge compared the performance of computerized methods in the task of differentiating benign from malignant lung nodules on CT scans, placed in the context of the performance of radiologists on the same task. The continued public availability of the Challenge cases will provide a valuable resource for the medical imaging research community. PMID:28018939
LUNGx Challenge for computerized lung nodule classification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Armato, Samuel G.; Drukker, Karen; Li, Feng
The purpose of this work is to describe the LUNGx Challenge for the computerized classification of lung nodules on diagnostic computed tomography (CT) scans as benign or malignant and report the performance of participants’ computerized methods along with that of six radiologists who participated in an observer study performing the same Challenge task on the same dataset. The Challenge provided sets of calibration and testing scans, established a performance assessment process, and created an infrastructure for case dissemination and result submission. We present ten groups that applied their own methods to 73 lung nodules (37 benign and 36 malignant) thatmore » were selected to achieve approximate size matching between the two cohorts. Area under the receiver operating characteristic curve (AUC) values for these methods ranged from 0.50 to 0.68; only three methods performed statistically better than random guessing. The radiologists’ AUC values ranged from 0.70 to 0.85; three radiologists performed statistically better than the best-performing computer method. The LUNGx Challenge compared the performance of computerized methods in the task of differentiating benign from malignant lung nodules on CT scans, placed in the context of the performance of radiologists on the same task. Lastly, the continued public availability of the Challenge cases will provide a valuable resource for the medical imaging research community.« less
NASA Astrophysics Data System (ADS)
Weiner, Michael W.; Maudsley, Andrew A.; Schuff, Norbert; Soher, Brian J.; Vermathen, Peter P.; Fein, George; Laxer, Kenneth D.
1998-07-01
Proton magnetic resonance spectroscopic imaging (1H MRSI) with volume pre-selection (i.e. by PRESS) or multislice 1H MRSI was used to investigate changes in brain metabolites in Alzheimer's disease, epilepsy, and amyotrophic lateral sclerosis. Examples of results from several ongoing clinical studies are provided. Multislice 1H MRSI of the human brain, without volume pre-selection offers considerable advantages over previously available techniques. Furthermore, MRI tissue segmentation and completely automated spectra curve fitting greatly facilitate quantitative data analysis. Future efforts will be devoted to obtaining full brain coverage and data acquisition at short spin echo times (TE less than 30 ms) for the detection of metabolites with short T2 relaxation times.
Lee, Fernandes Carmen; Fernandes, C M C; Murrell, H C
2009-06-01
This study is an anatomical study designed to benefit surgeons working in the region of the maxillary sinus. This paper investigates ethnic and gender variations in the shape of the maxillary sinus in dried crania from the Raymond Dart collection of human skeletons. The paper claims that an estimate of the area of the medial antral wall of the maxillary sinus is one of the best ethnic/gender group predictors. Helical, multislice computed tomography was performed using 1mm coronal slices length, depth, width and volume measurements for each sinus were taken. Classification by shape and estimated area of medial wall was attempted. Shape classification was found to be unsuccessful whilst medial wall classification into ethnic/gender groupings gave encouraging results. The area of the medial wall is related to ethnic/gender groups.
CT and MRI slice separation evaluation by LabView developed software.
Acri, Giuseppe; Testagrossa, Barbara; Sestito, Angela; Bonanno, Lilla; Vermiglio, Giuseppe
2018-02-01
The efficient use of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) equipment necessitates establishing adequate quality-control (QC) procedures. In particular, the accuracy of slice separation, during multislices acquisition, requires scan exploration of phantoms containing test objects. To simplify such procedures, a novel phantom and a computerised LabView-based procedure have been devised, enabling determination the midpoint of full width at half maximum (FWHM) in real time while the distance from the profile midpoint of two progressive images is evaluated and measured. The results were compared with those obtained by processing the same phantom images with commercial software. To validate the proposed methodology the Fisher test was conducted on the resulting data sets. In all cases, there was no statistically significant variation between the commercial procedure and the LabView one, which can be used on any CT and MRI diagnostic devices. Copyright © 2017. Published by Elsevier GmbH.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crowhurst, James A; Campbell, Douglas; Whitby, Mark
A patient with a medial and posterior dislocation of the right sterno-clavicular (SC) joint and displacement of the trachea and brachiocephalic artery by the medial head of the clavicle underwent general anaesthetic in the operating theatre for an open reduction procedure. The surgeon initially attempted a closed reduction, but this required imaging to check SC alignment. The patient was transferred to an adjacent hybrid operating theatre for imaging. Cone beam computed tomography (CBCT) was performed, which successfully demonstrated a significant reduction in the dislocation of the SC joint. The trachea and brachiocephalic artery were no longer compressed or displaced. Thismore » case study demonstrates an alternative to the patient being transferred to the medical imaging department for multi-slice CT. It also describes a novel use of the hybrid operating theatre and its CBCT capabilities.« less
Peramaki, Ed R
2011-05-01
Radiographic assessment of combat injuries has been an important component of casualty care in every major conflict of the 20th and 21st centuries. The advent of multislice computed tomography scanners has provided physicians with the ability to visualize organ injury at submillimetre resolution, changing the way war wounds are treated. Modern wars are, for the most part, asymmetric conflicts where improvised explosive devices have replaced artillery as a major cause of casualties. Both bullets and explosive devices wreak distinctive patterns of injury on the human body. Being able to recognize these patterns and their potential associated morbidities will allow medical personnel to provide expert and timely care to some of the most severely injured patients on earth. This series of pictorial essays will review the radiographic patterns of combat-related injury encountered in southern Afghanistan in 2008-2009.
Pancreatic trauma: demographics, diagnosis, and management.
Stawicki, Stanislaw Peter; Schwab, C William
2008-12-01
Pancreatic injuries are rare, with penetrating mechanisms being causative in majority of cases. They can create major diagnostic and therapeutic challenges and require multiple diagnostic modalities, including multislice high-definition computed tomography, magnetic resonance cholangiopancreatography, endoscopic retrograde cholangiopancreatography, ultrasonography, and at times, surgery and direct visualization of the pancreas. Pancreatic trauma is frequently associated with duodenal and other severe vascular and visceral injuries. Mortality is high and usually related to the concomitant vascular injury. Surgical management of pancreatic and pancreatic-duodenal trauma is challenging, and multiple surgical approaches and techniques have been described, up to and including pancreatic damage control and later resection and reconstruction. Wide surgical drainage is a key to any surgical trauma technique and access for enteral nutrition, or occasionally parenteral nutrition, are important adjuncts. Morbidity associated with pancreatic trauma is high and can be quite severe. Treatment of pancreatic trauma-related complications often requires a combination of interventional, endoscopic, and surgical approaches.
Fimag: the United Kingdom disaster victim/forensic identification imaging system.
Rutty, Guy N; Robinson, Claire; Morgan, Bruno; Black, Sue; Adams, Catherine; Webster, Philip
2009-11-01
Imaging is an integral diagnostic tool in mass fatality investigations undertaken traditionally by plain X-rays, fluoroscopy, and dental radiography. However, little attention has been given to appropriate image reporting, secure data transfer and storage particularly in relation to the need to meet stringent judicial requirements. Notwithstanding these limitations, it is the risk associated with the safe handling and investigation of contaminated fatalities which is providing new challenges for mass fatality radiological imaging. Mobile multi-slice computed tomography is an alternative to these traditional modalities as it provides a greater diagnostic yield and an opportunity to address the requirements of the criminal justice system. We present a new national disaster victim/forensic identification imaging system--Fimag--which is applicable for both contaminated and non-contaminated mass fatality imaging and addresses the issues of judicial reporting. We suggest this system opens a new era in radiological diagnostics for mass fatalities.
Mid-Frequency Sonar Interactions with Beaked Whales
2011-06-30
Beaked Whale, was not completed. However, several other goals were achieved, including synthesis of a morphometric model of a beaked whale. This and work...induced acoustic fields inside beaked whales and other marine mammals. Another high-level goal was to acquire new high-resolution morphometric and...range 1-10 kHz; collecting high-resolution morphometric data through computerized tomography (CT) scans on marine mammal specimens, and constructing
NASA Astrophysics Data System (ADS)
Gong, Hao; Yu, Lifeng; Leng, Shuai; Dilger, Samantha; Zhou, Wei; Ren, Liqiang; McCollough, Cynthia H.
2018-03-01
Channelized Hotelling observer (CHO) has demonstrated strong correlation with human observer (HO) in both single-slice viewing mode and multi-slice viewing mode in low-contrast detection tasks with uniform background. However, it remains unknown if the simplest single-slice CHO in uniform background can be used to predict human observer performance in more realistic tasks that involve patient anatomical background and multi-slice viewing mode. In this study, we aim to investigate the correlation between CHO in a uniform water background and human observer performance at a multi-slice viewing mode on patient liver background for a low-contrast lesion detection task. The human observer study was performed on CT images from 7 abdominal CT exams. A noise insertion tool was employed to synthesize CT scans at two additional dose levels. A validated lesion insertion tool was used to numerically insert metastatic liver lesions of various sizes and contrasts into both phantom and patient images. We selected 12 conditions out of 72 possible experimental conditions to evaluate the correlation at various radiation doses, lesion sizes, lesion contrasts and reconstruction algorithms. CHO with both single and multi-slice viewing modes were strongly correlated with HO. The corresponding Pearson's correlation coefficient was 0.982 (with 95% confidence interval (CI) [0.936, 0.995]) and 0.989 (with 95% CI of [0.960, 0.997]) in multi-slice and single-slice viewing modes, respectively. Therefore, this study demonstrated the potential to use the simplest single-slice CHO to assess image quality for more realistic clinically relevant CT detection tasks.
He, Bosheng; Gu, Jinhua; Huang, Sheng; Gao, Xuesong; Fan, Jinhe; Sheng, Meihong; Wang, Lin; Gong, Shenchu
2017-02-01
This study was performed to evaluate the diagnostic performance of multi-slice CT angiography combined with enterography in determining the cause and location of obstruction as well as intestinal ischaemia in patients with small bowel obstruction (SBO). This study retrospectively summarized the image data of 57 SBO patients who received both multi-slice CT angiography and enterography examination between December 2012 and May 2013. The CT diagnoses of SBO and intestinal ischaemia were correlated with the findings at surgery or digital subtraction angiography, which were set as standard references. Multi-slice CT angiography and enterography indicated that the cause of SBO in three patients was misjudged, suggesting a diagnostic accuracy of 94.7%. In one patient the level of obstruction was incorrect, demonstrating a diagnostic accuracy of 98.2%. Based on the results of the receiver operating characteristic (ROC) curve analysis, the diagnostic criterion for ischaemic SBO was at least two of the four CT signs (circumferential bowel wall thickening, reduced enhancement of the intestinal wall, mesenteric oedema and mesenteric vascular engorgement). The criterion yielded a sensitivity of 94.4%, a specificity of 92.3%, a positive predicted value of 85.0% and a negative predicted value of 97.3%, and the area under curve (AUC) was 0.92 (95% CI, 0.85-0.99). Multi-slice CT angiography and enterography have high diagnostic value in identifying the cause and site of SBO. In addition, the suggested diagnostic criterion using CT signs is helpful for diagnosing intestinal ischaemia in SBO patients. © 2016 The Royal Australian and New Zealand College of Radiologists.
Multislice spiral CT simulator for dynamic cardiopulmonary studies
NASA Astrophysics Data System (ADS)
De Francesco, Silvia; Ferreira da Silva, Augusto M.
2002-04-01
We've developed a Multi-slice Spiral CT Simulator modeling the acquisition process of a real tomograph over a 4-dimensional phantom (4D MCAT) of the human thorax. The simulator allows us to visually characterize artifacts due to insufficient temporal sampling and a priori evaluate the quality of the images obtained in cardio-pulmonary studies (both with single-/multi-slice and ECG gated acquisition processes). The simulating environment allows both for conventional and spiral scanning modes and includes a model of noise in the acquisition process. In case of spiral scanning, reconstruction facilities include longitudinal interpolation methods (360LI and 180LI both for single and multi-slice). Then, the reconstruction of the section is performed through FBP. The reconstructed images/volumes are affected by distortion due to insufficient temporal sampling of the moving object. The developed simulating environment allows us to investigate the nature of the distortion characterizing it qualitatively and quantitatively (using, for example, Herman's measures). Much of our work is focused on the determination of adequate temporal sampling and sinogram regularization techniques. At the moment, the simulator model is limited to the case of multi-slice tomograph, being planned as a next step of development the extension to cone beam or area detectors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kinney, J.
This session is comprised of two articles by John Kinney describing biomedical and other uses for computerized tomography. In the first article, Kinney describes the use of a three-dimensional x-ray tomographic microscope to image the trabecular bone architecture of the proximal tibias of rats in vivo. Research in this field may help to detect the earliest stages of hypoestrogenemic bone loss and may help to more rapidly test the effectiveness of new clinical treatments for this major public health problem. The second article describes recent advances in X-ray tomography using synchrotron radiation to evaluate microstructures in ceramic matrix composites, bonemore » loss in osteoporosis, and the development of carries lesions in teeth.« less
Heidelberg Retina Tomography Analysis in Optic Disks with Anatomic Particularities
Alexandrescu, C; Pascu, R; Ilinca, R; Popescu, V; Ciuluvica, R; Voinea, L; Celea, C
2010-01-01
Due to its objectivity, reproducibility and predictive value confirmed by many large scale statistical clinical studies, Heidelberg Retina Tomography has become one of the most used computerized image analysis of the optic disc in glaucoma. It has been signaled, though, that the diagnostic value of Moorfieds Regression Analyses and Glaucoma Probability Score decreases when analyzing optic discs with extreme sizes. The number of false positive results increases in cases of megalopapilllae and the number of false negative results increases in cases of small size optic discs. The present paper is a review of the aspects one should take into account when analyzing a HRT result of an optic disc with anatomic particularities. PMID:21254731
Detterbeck, Andreas; Hofmeister, Michael; Hofmann, Elisabeth; Haddad, Daniel; Weber, Daniel; Hölzing, Astrid; Zabler, Simon; Schmid, Matthias; Hiller, Karl-Heinz; Jakob, Peter; Engel, Jens; Hiller, Jochen; Hirschfelder, Ursula
2016-07-01
To examine the relative usefulness and suitability of magnetic resonance imaging (MRI) in daily clinical practice as compared to various technologies of computed tomography (CT) in addressing questions of orthodontic interest. Three blinded raters evaluated 2D slices and 3D reconstructions created from scans of two pig heads. Five imaging modalities were used, including three CT technologies-multislice (MSCT), cone-beam CT (CBCT), and industrial (µCT)-and two MRI protocols with different scan durations. Defined orthodontic parameters were rated one by one on the 2D slices and the 3D reconstructions, followed by final overall ratings for each modality. A mixed linear model was used for statistical analysis. Based on the 2D slices, the parameter of visualizing tooth-germ topography did not yield any significantly different ratings for MRI versus any of the CT scans. While some ratings for the other parameters did involve significant differences, how these should be interpreted depends greatly on the relevance of each parameter. Based on the 3D reconstructions, the only significant difference between technologies was noted for the parameter of visualizing root-surface morphology. Based on the final overall ratings, the imaging performance of the standard MRI protocol was noninferior to the performance of the three CT technologies. On comparing the imaging performance of MRI and CT scans, it becomes clear that MRI has a huge potential for applications in daily clinical practice. Given its additional benefits of a good contrast ratio and complete absence of ionizing radiation, further studies are needed to explore this clinical potential in greater detail.
Syeda, Bonni; Höfer, Peter; Pichler, Philipp; Vertesich, Markus; Bergler-Klein, Jutta; Roedler, Susanne; Mahr, Stephane; Goliasch, Georg; Zuckermann, Andreas; Binder, Thomas
2011-07-01
Longitudinal strain determined by speckle tracking is a sensitive parameter to detect systolic left ventricular dysfunction. In this study, we assessed regional and global longitudinal strain values in long-term heart transplants and compared deformation indices with ejection fraction as determined by transthoracic echocardiography (TTE) and multislice computed tomographic coronary angiography (MSCTA). TTE and MSCTA were prospectively performed in 31 transplant patients (10.6 years post-transplantation) and in 42 control subjects. Grey-scale apical views were recorded for speckle tracking (EchoPAC 7.0, GE) of the 16 segments of the left ventricle. The presence of coronary artery disease (CAD) was assessed by MSCTA. Strain analysis was performed in 1168 segments [496 in transplant patients (42.5%), 672 in control subjects (57.7%)]. Global longitudinal peak systolic strain was significantly lower in the transplant recipients than in the healthy population (-13.9 ± 4.2 vs. -17.4 ± 5.8%, P< 0.01). This was still the case after exclusion of the nine transplant patients with CAD (-14.1 ± 4.4 vs. -17.4 ± 5.8%, P=0.03). Transplant patients exhibited significantly lower regional strain values in 9 of the 16 segments. Left ventricular ejection fraction (%) (MSCTA/Simpsons method) was 60.7 ± 10.1%/60.2 ± 6.7% in transplant recipients vs. 64.7 ± 6.4%/63.0 ± 6.2% in the healthy population, P=ns. Even though 'healthy' heart transplants without CAD exhibit normal ejection fraction, deformation indices are reduced in this population when compared with control subjects. Our findings suggests that strain analysis is more sensitive than assessment of ejection fraction for the detection of abnormalities of systolic function.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oztunc, Funda, E-mail: foztunc@yahoo.com; Baris, Safa, E-mail: safabaris@hotmail.co; Adaletli, Ibrahim, E-mail: iadaletli@yahoo.com
2009-03-15
The purpose of this study was to evaluate the feasibility of multislice computed tomographic (MSCT) angiography as a noninvasive method for detecting ostial, proximal, and middle segment coronary stenosis or occlusion and anatomy in patients with transposition of the great arteries who had undergone arterial switch operation (ASO). Sixteen-detector-row MSCT angiography was performed in 16 patients treated with ASO for transposition of the great arteries. The median age was 10.3 years (range, 6.2-16.3 years). Sixteen-detector-row MSCT angiography was performed in 16 patients who had undergone ASO. CT imaging was performed in the craniocaudal direction from 2 cm above the carinamore » up to the heart basis. Noninvasive assessment of coronary artery stenosis and anatomy were investigated by MSCT angiography. Two patients were excluded from the study because of artifacts. Of 14 evaluated patients, 1 patient had ostial stenosis (7.1%). A coronary artery anatomy variant was present in six patients: left main artery (LMA) and right coronary artery (RCA) originating from the right sinus as a single orifice (n = 2); left circumflex artery (LCX) originating from the RCA (n = 1); LMA and RCA, after branching to the LCX, originating separately from the right sinus (n = 1); and LMA (n = 1) and left anterior descending artery (LADA; n = 1) originating directly from the right sinus. Intramural bridging in the LAD (n = 2) was detected. Five patients were normal. In conclusion, MSCT angiography, as a noninvasive, feasible technique for assessing coronary stenosis or occlusion and anatomy, can be used in the follow-up of patients who have undergone ASO.« less
Multislice does it all—calculating the performance of nanofocusing X-ray optics
Li, Kenan; Wojcik, Michael; Jacobsen, Chris
2017-01-23
Here, we describe an approach to calculating the optical performance of a wide range of nanofocusing X-ray optics using multislice scalar wave propagation with a complex X-ray refractive index. This approach produces results indistinguishable from methods such as coupled wave theory, and it allows one to reproduce other X-ray optical phenomena such as grazing incidence reflectivity where the direction of energy flow is changed significantly. Just as finite element analysis methods allow engineers to compute the thermal and mechanical responses of arbitrary structures too complex to model by analytical approaches, multislice propagation can be used to understand the properties ofmore » the real-world optics of finite extent and with local imperfections, allowing one to better understand the limits to nanoscale X-ray imaging.« less
Masum, M A; Pickering, M R; Lambert, A J; Scarvell, J M; Smith, P N
2017-09-06
In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment followed by transform parameters estimation greatly reduces the complexity and provides sufficient accuracy. In this approach, the Hough Transform (HT) is used to further enhance the image features which originate from the image feature enhancing elements integrated into the physical phantom model, thus reducing feature detection uncertainty. In this framework, slice by slice image alignment and calibration are carried out and this provides manual ease and convenience. Copyright © 2016 Elsevier Ltd. All rights reserved.
Miller, Julie M; Dewey, Marc; Vavere, Andrea L; Rochitte, Carlos E; Niinuma, Hiroyuki; Arbab-Zadeh, Armin; Paul, Narinder; Hoe, John; de Roos, Albert; Yoshioka, Kunihiro; Lemos, Pedro A; Bush, David E; Lardo, Albert C; Texter, John; Brinker, Jeffery; Cox, Christopher; Clouse, Melvin E; Lima, João A C
2009-04-01
Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective "CORE-64" trial ("Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors"). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.
Joshi, Hasit; Shah, Ronak; Prajapati, Jayesh; Bhangdiya, Vipin; Shah, Jayal; Kandre, Yogini; Shah, Komal
2016-01-01
Objective: To compare the diagnostic accuracy of multi-slice computed tomography (MSCT) angiography with conventional angiography in patients undergoing major noncoronary cardiac surgeries. Materials and Methods: We studied fifty major noncoronary cardiac surgery patients scheduled for invasive coronary angiography, 29 (58%) female and 21 (42%) male. Inclusion criteria of the study were age of the patients ≥40 years, having low or intermediate probability of coronary artery disease (CAD), left ventricular ejection fraction (LVEF) >35%, and patient giving informed consent for undergoing MSCT and conventional coronary angiography. The patients with LVEF <35%, high pretest probability of CAD, and hemodynamically unstable were excluded from the study. Results: The diagnostic accuracy of CT coronary angiography was evaluated regarding true positive, true negative values. The overall sensitivity and specificity of CT angiography technique was 100% (95% confidence interval [CI]: 39.76%–100%) and 91.30% (95% CI: 79.21%–97.58%). The positive (50%; 95% CI: 15.70%–84.30%) and negative predictive values (100%; 95% CI: 91.59%–100%) of CT angiography were also fairly high in these patients. Conclusion: Our study suggests that this non-invasive technique may improve perioperative risk stratification in patients undegoing non-cardiac surgery. PMID:27867455
Limongi, Orlando; de Albuquerque, Diana Santana; Baratto Filho, Flares; Vanni, José Roberto; de Oliveira, Elias P Motcy; Barletta, Fernando Branco
2007-01-01
This in vitro study compared, using computed tomography (CT), the amount of dentin removed from root canal walls by manual and mechanical rotary instrumentation techniques. Forty mandibular incisors with dental crown and a single canal were selected. The teeth were randomly assigned to two groups, according to the technique used for root canal preparation: Group I - manual instrumentation with stainless steel files; Group II - mechanical instrumentation with RaCe rotary nickel-titanium instruments. In each tooth, root dentin thickness of the buccal, lingual, mesial and distal surfaces in the apical, middle and cervical thirds of the canal was measured (in mm) using a multislice CT scanner (Siemens Emotion, Duo). Data were stored in the SPSS v. 11.5 and SigmaPlot 2001 v. 7.101 softwares. After crown opening, working length was determined, root canals were instrumented and new CT scans were taken for assessment of root dentin thickness. Pre- and post-instrumentation data were compared and analyzed statistically by ANOVA and Tukey's post-hoc test for significant differences (p=0.05). Based on the findings of this study, it may be concluded that regarding dentin removal from root canal walls during instrumentation, neither of the techniques can be considered more effective than the other.
Displacement of a Broken Dental Injection Needle Into the Perivertebral Space.
Sahin, Bayram; Yildirimturk, Senem; Sirin, Yigit; Basaran, Bora
2017-07-01
Dental injection needle breakage is an uncommon problem in dental practice. Displacement of the broken fragment into anatomical spaces is, on the other hand, a serious complication that occurs most commonly during inferior alveolar nerve blocks as a result of material wear, incorrect application of the anesthesia technique, or sudden movement of the patient during injection. Further complications such as infection, trismus, and nerve paralysis may exacerbate the condition and, if not treated adequately, life-threatening conditions may develop over time as the fragment dislodges deeper in soft tissues. Clinical symptoms of the patient, as well as the findings gathered from detailed physical examination and radiographic evaluation, are important factors to consider before performing an exploratory surgery. Removal of a broken needle may be troublesome due to its proximity to vital anatomic structures. Multislice computed tomography is a reliable imaging modality that provides accurate information to pinpoint the exact location of the needle fragment.This report describes a case of needle breakage occurred during inferior alveolar nerve block which was performed to extract a third molar tooth and the migration of the broken fragment from the right mandibular ramus area into the perivertebral space, with special emphasis on the surgical retrieval technique with multiplanar computed tomography imaging guidance.
Amraoui, Sana; Tlili, Ghoufrane; Sohal, Manav; Bordenave, Laurence; Bordachar, Pierre
2016-12-01
18-Fluorodeoxyglucose positron emission tomography/computerized tomography (FDG PET/CT) scanning has recently been proposed as a diagnostic tool for lead endocarditis (LE). FDG PET/CT might be also useful to localize associated septic emboli in patients with LE. We report an interesting case of a LE patient with a prosthetic aortic valve in whom a trans-esophageal echocardiogram did not show associated aortic endocarditis. FDG PET/CT revealed prosthetic aortic valve infection. A second TEE performed 2 weeks after identified aortic vegetation. A longer duration of antimicrobial therapy with serial follow-up echocardiography was initiated. There was also increased uptake in the sigmoid colon, corresponding to focal polyps resected during a colonoscopy. FDG PET/CT scanning seems to be highly sensitive for prosthetic aortic valve endocarditis diagnosis. This promising diagnostic tool may be beneficial in LE patients, by identifying septic emboli and potential sites of pathogen entry.
How to evaluate and compare maintenance contracts: a checklist.
Gustine, S M; Young, P
1986-07-01
Several factors need to be considered when comparing computerized tomography (CT) maintenance contracts. Five areas in particular require careful review to ensure that an institution is getting maximum value for its contract dollars: the credibility of the servicing company; the servicing engineer's qualifications and commitments; a thorough understanding of contract terminology; accurate analysis standards; and professionalism. The following article examines each of these areas in closer detail.
Ruptured intracranial dermoid: an unusual cause of headache in an older patient.
Rajapakse, Anoja; Diack, Alison
2008-02-01
A 76-year-old woman with a history of migraine presented with worsening headache. Computerized tomography brain scan and magnetic resonance imaging brain scan showed the presence of fat globules in the cerebrospinal fluid space. This appearance was suggestive of ruptured intracranial dermoid. She recovered spontaneously. While headache is a known presentation of ruptured intracranial dermoid, the condition is unusual to present in older people.
Phenylpropanolamine and cerebral hemorrhage
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDowell, J.R.; LeBlanc, H.J.
1985-05-01
Computerized tomography, carotid angiograms, and arteriography were used to diagnose several cases of cerebral hemorrhage following the use of phenylpropanolamine. The angiographic picture in one of the three cases was similar to that previously described in association with amphetamine abuse and pseudoephedrine overdose, both substances being chemically and pharmacologically similar to phenylpropanolamine. The study suggests that the arterial change responsible for symptoms may be due to spasm rather than arteriopathy. 14 references, 5 figures.
Mid-Frequency Sonar Interactions With Beaked Whales
2009-09-30
to acquire new high-resolution morphometric and physical-property data on beaked whales for use in the model. It is hoped that the availability of such... morphometric and physical-property data on beaked whales for use in the model. It is hoped that the availability of such a system, together with high-quality... morphometric data through computerized tomography (CT) scans on marine mammal carcasses, and constructing finite-element models of the anatomy
Use Case Analysis: The Ambulatory EEG in Navy Medicine for Traumatic Brain Injuries
2016-12-01
best uses of the device for naval medicine. 14. SUBJECT TERMS traumatic brain injuries, electroencephalography, EEG, use case study 15. NUMBER OF...Traumatic Brain Injury NCS Non-Convulsive Seizures PD Parkinson’s Disease QEEG Quantitative EEG SPECT Single-Photon Emission Computerized Tomography...INTENTIONALLY LEFT BLANK 1 I. INTRODUCTION This study examines the diagnosis of traumatic brain injuries (TBI). Early detection and diagnosis is
Dual scan CT image recovery from truncated projections
NASA Astrophysics Data System (ADS)
Sarkar, Shubhabrata; Wahi, Pankaj; Munshi, Prabhat
2017-12-01
There are computerized tomography (CT) scanners available commercially for imaging small objects and they are often categorized as mini-CT X-ray machines. One major limitation of these machines is their inability to scan large objects with good image quality because of the truncation of projection data. An algorithm is proposed in this work which enables such machines to scan large objects while maintaining the quality of the recovered image.
A modified conjugate gradient method based on the Tikhonov system for computerized tomography (CT).
Wang, Qi; Wang, Huaxiang
2011-04-01
During the past few decades, computerized tomography (CT) was widely used for non-destructive testing (NDT) and non-destructive examination (NDE) in the industrial area because of its characteristics of non-invasiveness and visibility. Recently, CT technology has been applied to multi-phase flow measurement. Using the principle of radiation attenuation measurements along different directions through the investigated object with a special reconstruction algorithm, cross-sectional information of the scanned object can be worked out. It is a typical inverse problem and has always been a challenge for its nonlinearity and ill-conditions. The Tikhonov regulation method is widely used for similar ill-posed problems. However, the conventional Tikhonov method does not provide reconstructions with qualities good enough, the relative errors between the reconstructed images and the real distribution should be further reduced. In this paper, a modified conjugate gradient (CG) method is applied to a Tikhonov system (MCGT method) for reconstructing CT images. The computational load is dominated by the number of independent measurements m, and a preconditioner is imported to lower the condition number of the Tikhonov system. Both simulation and experiment results indicate that the proposed method can reduce the computational time and improve the quality of image reconstruction. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.
Brachytherapy of prostate cancer after colectomy for colorectal cancer: pilot experience.
Koutrouvelis, Panos G; Theodorescu, Dan; Katz, Stuart; Lailas, Niko; Hendricks, Fred
2005-01-01
We present a method of brachytherapy for prostate cancer using a 3-dimensional stereotactic system and computerized tomography guidance in patients without a rectum due to previous treatment for colorectal cancer. From June 1994 to November 2003 a cohort of 800 patients were treated with brachytherapy for prostate cancer. Four patients had previously been treated for colorectal cancer with 4,500 cGy external beam radiation therapy, abdominoperineal resection and chemotherapy, while 1 underwent abdominoperineal resection alone for ulcerative colitis. Because of previous radiation therapy, these patients were not candidates for salvage external beam radiation therapy or radical prostatectomy and they had no rectum for transrectal ultrasound guided transperineal brachytherapy or cryotherapy. A previously described, 3-dimensional stereotactic system was used for brachytherapy in these patients. The prescribed radiation dose was 120 to 144 Gy with iodine seeds in rapid strand format. Patient followup included clinical examination and serum prostate specific antigen measurement. Average followup was 18.6 months. Four patients had excellent biochemical control, while 1 had biochemical failure. Patients did not experience any gastrointestinal morbidity. One patient had a stricture of the distal ureter, requiring a stent. Three-dimensional computerized tomography guided brachytherapy for prostate cancer in patients with a history of colorectal cancer who have no rectum is a feasible method of treatment.
Caillaud, C; Serre-Cousiné, O; Anselme, F; Capdevilla, X; Préfaut, C
1995-10-01
We investigated the computerized tomographies (CTs) of the thorax and the pulmonary diffusing capacity for CO (DLCO) in eight male athletes before and after a triathlon. DLCO and alveolar volume (VA) were simultaneously measured during 9 s of breath holding. The transfer coefficient (KCO = DLCO/VA) was then calculated. CT scanning was performed during breath holding with the subjects in the supine position. Scanner analysis was done by 1) counting the linear and polygonal opacities (index of interstitial fluid accumulation) and 2) calculating the physical mean lung density and the mean slice mass. Results showed a significant reduction in DLCO (44.9 +/- 2.3 vs. 42.9 +/- 1.7 ml.min-1.mmHg-1; P < 0.05) and KCO (6.0 +/- 0.3 vs. 5.6 +/- 0.3 ml.min-1.mmHg-1.l of VA-1; P < 0.05) after the triathlon and an increase in mean lung density (0.21 +/- 0.009 vs. 0.25 +/- 0.01 g/cm3; P < 0.0001). The number of polygonal and linear opacities increased after the race (P < 0.001). This study confirmed that DLCO and KCO decrease in elite athletes after a long-distance race and showed a concomitant increase in CT lung density and in the number of opacities.
Harjula, A; Järvinen, A; Mattila, S; Porkka, L
1985-01-01
Single photon emission computerized tomography (SPECT) was performed thrice in ten patients undergoing open-heart surgery--preoperatively and 2 and 12 weeks postoperatively. The operations were done for ischemic heart disease (5), aortic valvular stenosis (2), aortic valvular insufficiency (1), leaking mitral prosthetic valve (1) and combined aortic and mitral valvular stenosis and insufficiency (1). The healing process in the longitudinally divided sternum was evaluated from the SPECT study. Four conventional static images in two dimensions were registered in anteroposterior, posteroanterior and left and right lateral projections. A tomographic study was done. Quantitative analyses were performed. The ratio of the sternal counts to the counts from a thoracic vertebra was calculated for use as a reference. The activity ratios showed a similar pattern in six cases, with initial increases and at 12 weeks slight decrease compared with the preoperative values. In two cases the activity was still increasing after 12 postoperative weeks. One patient, with sternotomy also one year previously, showed only slightly increased activity. The activity at the areas of the sternal wires was increased in six cases. The study thus revealed differing patterns of isotope uptake, although recovery was uneventful in all patients. The differences may reflect the possibility that the operative course and the preoperative clinical status can influence the healing mechanisms.
Kimel-Naor, Shani; Abboud, Shimon; Arad, Marina
2016-08-01
Osteoporosis is defined as bone microstructure deterioration resulting a decrease of bone's strength. Measured bone mineral density (BMD) constitutes the main tool for Osteoporosis diagnosis, management, and defines patient's fracture risk. In the present study, parametric electrical impedance tomography (pEIT) method was examined for monitoring BMD, using a computerized simulation model and preliminary real measurements. A numerical solver was developed to simulate surface potentials measured over a 3D computerized pelvis model. Varying cortical and cancellous BMD were simulated by changing bone conductivity and permittivity. Up to 35% and 16% change was found in the real and imaginary modules of the calculated potential, respectively, while BMD changes from 100% (normal) to 60% (Osteoporosis). Negligible BMD relative error was obtained with SNR>60 [dB]. Position changes errors indicate that for long term monitoring, measurement should be taken at the same geometrical configuration with great accuracy. The numerical simulations were compared to actual measurements that were acquired from a healthy male subject using a five electrodes belt bioimpedance device. The results suggest that pEIT may provide an inexpensive easy to use tool for frequent monitoring BMD in small clinics during pharmacological treatment, as a complementary method to DEXA test. Copyright © 2016. Published by Elsevier Ltd.
Acar, Nihat; Karakasli, Ahmet; Karaarslan, Ahmet; Mas, Nermin Ng; Hapa, Onur
2017-01-01
Volumetric measurements of benign tumors enable surgeons to trace volume changes during follow-up periods. For a volumetric measurement technique to be applicable, it should be easy, rapid, and inexpensive and should carry a high interobserver reliability. We aimed to assess the interobserver reliability of a volumetric measurement technique using the Cavalier's principle of stereological methods. The computerized tomography (CT) of 15 patients with a histopathologically confirmed diagnosis of enchondroma with variant tumor sizes and localizations was retrospectively reviewed for interobserver reliability evaluation of the volumetric stereological measurement with the Cavalier's principle, V = t × [((SU) × d) /SL]2 × Σ P. The volumes of the 15 tumors collected by the observers are demonstrated in Table 1. There was no statistical significance between the first and second observers ( p = 0.000 and intraclass correlation coefficient = 0.970) and between the first and third observers ( p = 0.000 and intraclass correlation coefficient = 0.981). No statistical significance was detected between the second and third observers ( p = 0.000 and intraclass correlation coefficient = 0.976). The Cavalier's principle with the stereological technique using the CT scans is an easy, rapid, and inexpensive technique in volumetric evaluation of enchondromas with a trustable interobserver reliability.
Koivisto, J; Kiljunen, T; Tapiovaara, M; Wolff, J; Kortesniemi, M
2012-09-01
The aims of this study were to assess the organ and effective dose (International Commission on Radiological Protection (ICRP) 103) resulting from dental cone-beam computerized tomography (CBCT) imaging using a novel metal-oxide semiconductor field-effect transistor (MOSFET) dosimeter device, and to assess the reliability of the MOSFET measurements by comparing the results with Monte Carlo PCXMC simulations. Organ dose measurements were performed using 20 MOSFET dosimeters that were embedded in the 8 most radiosensitive organs in the maxillofacial and neck area. The dose-area product (DAP) values attained from CBCT scans were used for PCXMC simulations. The acquired MOSFET doses were then compared with the Monte Carlo simulations. The effective dose measurements using MOSFET dosimeters yielded, using 0.5-cm steps, a value of 153 μSv and the PCXMC simulations resulted in a value of 136 μSv. The MOSFET dosimeters placed in a head phantom gave results similar to Monte Carlo simulations. Minor vertical changes in the positioning of the phantom had a substantial affect on the overall effective dose. Therefore, the MOSFET dosimeters constitute a feasible method for dose assessment of CBCT units in the maxillofacial region. Copyright © 2012 Elsevier Inc. All rights reserved.
Arrestier, Romain; Dudreuilh, Caroline; Remy, Philippe; Boulahia, Ghada; Bentaarit, Bouteina; Leibler, Claire; Adedjouma, Amir; Kofman, Tomek; Matignon, Marie; Sahali, Dil; Dufresne, Roger; Deux, Jean-Francois; Colin, Charlotte; Grimbert, Philippe; Lang, Philippe; Bartolucci, Pablo; Maitre, Bernard; Tran Van Nhieu, Jeanne; Audard, Vincent
2016-01-01
Abstract Calciphylaxis is a small vessel vasculopathy, characterized by medial wall calcification that develops in a few patients with chronic renal failure. The prognosis of skin calciphylaxis has improved considerably since the introduction of sodium thiosulfate (STS), but it remains unclear whether this therapy is effective against organ lesions related to calciphylaxis. Pulmonary calciphylaxis is a usually fatal medical condition that may occur in association with skin involvement in patients with end-stage renal disease. We report here the case of a 49-year-old woman homozygous sickle cell disease patient on chronic hemodialysis with biopsy-proven systemic calciphylaxis involving the lungs and skin. On admission, ulcerative skin lesions on the lower limbs and bilateral pulmonary infiltrates on chest computerized tomography scan were the main clinical and radiological findings. Skin and bronchial biopsies demonstrated calciphylaxis lesions. The intravenous administration of STS in association with cinacalcet for 8 consecutive months led to a clear improvement in skin lesions and thoracic lesions on chest computerized tomography scan. This case suggests for the first time that organ lesions related to calciphylaxis, and particularly lung injury, are potentially reversible. This improvement probably resulted from the combination of 3 interventions (more frequent dialysis, cinacalcet, and STS), rather than the administration of STS alone. PMID:26871829
Computerized Doppler Tomography and Spectrum Analysis of Carotid Artery Flow
Morton, Paul; Goldman, Dave; Nichols, W. Kirt
1981-01-01
Contrast angiography remains the definitive study in the evaluation of atherosclerotic occlusive vascular disease. However, a safer technique for serial screening of symptomatic patients and for routine follow up is necessary. Computerized pulsed Doppler ultrasonic arteriography is a noninvasive technique developed by Miles6 for imaging lateral, antero-posterior and transverse sections of the carotid artery. We [ill] this system with new software and hardware to analyze the three-dimensional blood flow data. The system now provides information about the location of the occlusive process in the artery and a semi-quantitative evaluation of the degree of obstruction. In addition, we interfaced a digital signal analyzer to the system which permits spectrum analysis of the pulsed Doppler signal. This addition has allowed us to identify lesions which are not yet hemodynamically significant. ImagesFig. 2bFig. 2c
Ma, Guolin; Bai, Rongjie; Jiang, Huijie; Hao, Xuejia; Ling, Zaisheng; Li, Kefeng
2013-01-01
To develop an optimal scanning protocol for multislice spiral CT perfusion (CTP) imaging to evaluate hemodynamic changes in liver cirrhosis with diethylnitrosamine- (DEN-) induced precancerous lesions. Male Wistar rats were randomly divided into the control group (n = 80) and the precancerous liver cirrhosis group (n = 40). The control group received saline injection and the liver cirrhosis group received 50 mg/kg DEN i.p. twice a week for 12 weeks. All animals underwent plain CT scanning, CTP, and contrast-enhanced CT scanning. Scanning parameters were optimized by adjusting the diatrizoate concentration, the flow rate, and the delivery time. The hemodynamics of both groups was further compared using optimized multislice spiral CTP imaging. High-quality CTP images were obtained with following parameters: 150 kV; 150 mAs; 5 mm thickness, 5 mm interval; pitch, 1; matrix, 512 × 512; and FOV, 9.6 cm. Compared to the control group, the liver cirrhosis group had a significantly increased value of the hepatic arterial fraction and the hepatic artery perfusion (P < 0.05) but significantly decreased hepatic portal perfusion and mean transit time (P < 0.05). Multislice spiral CTP imaging can be used to evaluate the hemodynamic changes in the rat model of liver cirrhosis with precancerous lesions.
Chesnut, C Haile; Chesnut, Charles H
2012-03-01
Atypical femoral shaft fractures are associated with the extended usage of nitrogen-containing bisphosphonates as therapy for osteoporosis. For such fractures, the positron emission tomography (PET) procedure, coupled with computerized tomography (CT), provides a potential imaging modality for defining aspects of the pathogenesis, site specificity, and possible prodromal abnormalities prior to fracture. PET-CT may assess the radiokinetic variables K1 (a putative marker for skeletal blood flow) and Ki (a putative marker for skeletal bone formation), and when combined with PET imaging modalities and CT skeletal site localization, may define the site of such radiokinetic findings. Further studies into the clinical usage of PET-CT in patients with atypical femoral shaft fractures are warranted.
[Mobile CT at neurointensive sections--it is possible].
Frost, Majbritt; Stenkær, Susanne; Kellenberger, Simone; Ehlers, Lars
2011-01-24
Intrahospital transportation can be complicated and hazardous. Mobile computerized tomography (CT) of the head performed at the neurointensive care unit is a new technique that minimizes the need for transportation of unstable patients. Even small changes in physiological parameters can be detrimental for these patients and cause secondary injury and thus affect their prognoses. The portable CT scanner in the neurointensive care unit holds great potential, but the high price level may limit its use.
Rosemberg, S; Arita, F N; Campos, C; Alonso, F
1984-02-01
A case of hypomelanosis of Ito in a ten-year-old black boy with mental retardation, epilepsy and abnormalities of the white matter of the cerebral hemispheres revealed by a computerized tomography is presented. This is the 41st reported case on this disease, a number of which have shown neurological signs. A review of the literature with emphasis on the neurological manifestations is performed.
Macchi, Veronica; Regoli, Marì; Bracco, Sandra; Nicoletti, Claudio; Morra, Aldo; Porzionato, Andrea; De Caro, Raffaele; Bertelli, Eugenio
2016-03-01
In addition to the optic canal and the superior orbital fissure, orbits are connected with the cranial cavity via inconstant canals including the orbitomeningeal foramen. This study has been carried out in order to define many anatomical and radiological details of the orbitomeningeal foramen that are relevant in the clinical practice. Almost 1000 skulls and 50 computerized tomographies were examined to determine incidence, number, length, and caliber of the orbitomeningeal foramen as well as the topography of their orbital and cranial openings. A retrospective study of angiographies carried out on more than 100 children was performed to look for arteries candidate to run through the orbitomeningeal foramen. Orbitomeningeal foramina were detected in 59.46% of skulls and in 54% of individuals by computerized tomography. Orbits with two to five foramina were found. Canals were classified as M-subtype or A-subtype depending on their cranial opening. Large foramina, with the caliber ranging between 1 and 3 mm, were found in 12.17% of orbitomeningeal foramen-bearing orbits. By computed tomography the average caliber measured 1.2 ± 0.3 and 1.5 ± 0.5 mm (p < 0.005) at the orbital and cranial openings, respectively (p < 0.005). Angiographies showed meningo-lacrimal and meningo-ophthalmic arteries, meningeal branches of the lacrimal and supraorbital arteries, and some unidentified arteries that could pass through the orbitomeningeal foramina. Orbitomeningeal foramina are a common occurrence. When large they may house important arteries that can be the source of severe bleedings during deep dissection of the lateral wall of the orbit. Orbital surgeons should be aware of their existence.
Multi-slice ptychography with large numerical aperture multilayer Laue lenses
Ozturk, Hande; Yan, Hanfei; He, Yan; ...
2018-05-09
Here, the highly convergent x-ray beam focused by multilayer Laue lenses with large numerical apertures is used as a three-dimensional (3D) probe to image layered structures with an axial separation larger than the depth of focus. Instead of collecting weakly scattered high-spatial-frequency signals, the depth-resolving power is provided purely by the intense central cone diverged from the focused beam. Using the multi-slice ptychography method combined with the on-the-fly scan scheme, two layers of nanoparticles separated by 10 μm are successfully reconstructed with 8.1 nm lateral resolution and with a dwell time as low as 0.05 s per scan point. Thismore » approach obtains high-resolution images with extended depth of field, which paves the way for multi-slice ptychography as a high throughput technique for high-resolution 3D imaging of thick samples.« less
Multi-slice ptychography with large numerical aperture multilayer Laue lenses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozturk, Hande; Yan, Hanfei; He, Yan
Here, the highly convergent x-ray beam focused by multilayer Laue lenses with large numerical apertures is used as a three-dimensional (3D) probe to image layered structures with an axial separation larger than the depth of focus. Instead of collecting weakly scattered high-spatial-frequency signals, the depth-resolving power is provided purely by the intense central cone diverged from the focused beam. Using the multi-slice ptychography method combined with the on-the-fly scan scheme, two layers of nanoparticles separated by 10 μm are successfully reconstructed with 8.1 nm lateral resolution and with a dwell time as low as 0.05 s per scan point. Thismore » approach obtains high-resolution images with extended depth of field, which paves the way for multi-slice ptychography as a high throughput technique for high-resolution 3D imaging of thick samples.« less
O'Neill, Marisol; Huang, Gene O; Lamb, Dolores J
2017-12-01
The murine penis model has enriched our understanding of anomalous penile development. The morphologic characterization of the murine penis using conventional serial sectioning methods is labor intensive and prone to errors. To develop a novel application of micro-computerized tomography (micro-CT) with iodine staining for rapid, non-destructive morphologic study of murine penis structure. Penises were dissected from 10 adult wild-type mice and imaged using micro-CT with iodine staining. Images were acquired at 5-μm spatial resolution on a Bruker SkyScan 1272 micro-CT system. After images were acquired, the specimens were washed of any remaining iodine and embedded in paraffin for conventional histologic examination. Histologic and micro-CT measurements for all specimens were made by 2 independent observers. Measurements of penile structures were made on virtual micro-CT sections and histologic slides. The Lin concordance correlation coefficient demonstrated almost perfect strength of agreement for interobserver variability for histologic section (0.9995, 95% CI = 0.9990-0.9997) and micro-CT section (0.9982, 95% CI = 0.9963-0.9991) measurements. Bland-Altman analysis for agreement between the 2 modalities of measurement demonstrated mean differences of -0.029, 0.022, and -0.068 mm for male urogenital mating protuberance, baculum, and penile glans length, respectively. There did not appear to be a bias for overestimation or underestimation of measured lengths and limits of agreement were narrow. The enhanced ability offered by micro-CT to phenotype the murine penis has the potential to improve translational studies examining the molecular pathways contributing to anomalous penile development. The present study describes the first reported use of micro-CT with iodine staining for imaging the murine penis. Producing repeated histologic sections of identical orientation was limited by inherent imperfections in mounting and tissue sectioning, but this was compensated for by using micro-CT reconstructions to identify matching virtual sections. This study demonstrates the successful use of micro-CT with iodine staining, which has the potential for submicron spatial resolution, as a non-destructive method of characterizing murine penile morphology. O'Neill M, Huang GO, Lamb DJ. Novel Application of Micro-Computerized Tomography for Morphologic Characterization of the Murine Penis. J Sex Med 2017;14:1533-1539. Copyright © 2017. Published by Elsevier Inc.
Torricelli, Fabio C M; Marchini, Giovanni S; Yamauchi, Fernando I; Danilovic, Alexandre; Vicentini, Fabio C; Srougi, Miguel; Monga, Manoj; Mazzucchi, Eduardo
2015-06-01
We evaluated which variables impact fragmentation and clearance of lower pole calculi after shock wave lithotripsy. We prospectively evaluated patients undergoing shock wave lithotripsy for a solitary 5 to 20 mm lower pole kidney stone between June 2012 and August 2014. Patient body mass index and abdominal waist circumference were recorded. One radiologist blinded to shock wave lithotripsy outcomes measured stone size, area and density, stone-to-skin distance, infundibular length, width and height, and infundibulopelvic angle based on baseline noncontrast computerized tomography. Fragmentation, success (defined as residual fragments less than 4 mm in asymptomatic patients) and the stone-free rate were evaluated by noncontrast computerized tomography 12 weeks postoperatively. Univariate and multivariate analysis was performed. A total of 100 patients were enrolled in the study. Mean stone size was 9.1 mm. Overall fragmentation, success and stone-free rates were 76%, 54% and 37%, respectively. On logistic regression body mass index (OR 1.27, 95% CI 1.11-1.49, p = 0.004) and stone density (OR 1.0026, 95% CI 1.0008-1.0046, p = 0.005) significantly impacted fragmentation. Stone size (OR 1.24, 95% CI 1.07-1.48, p = 0.039) and stone density (OR 1.0021, 95% CI 1.0007-1.0037, p = 0.012) impacted the success rate while stone size (OR 1.24, 95% CI 1.04-1.50, p = 0.029), stone density (OR 1.0015, 95% CI 1.0001-1.0032, p = 0.046) and infundibular length (OR 1.1035, 95% CI 1.015-1.217, p = 0.015) impacted the stone-free rate. The best outcomes were found in patients with a body mass index of 30 kg/m(2) or less, stones 10 mm or less and 900 HU or less, and an infundibular length of 25 mm or less. The coexistence of significant unfavorable variables led to a stone-free rate of less than 20%. Obese patients with higher than 10 mm density stones (greater than 900 HU) in the lower pole of the kidney with an infundibular length of greater than 25 mm should be discouraged from undergoing shock wave lithotripsy. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Cerebral infarction in association with Ecstasy abuse.
Manchanda, S.; Connolly, M. J.
1993-01-01
A previously fit 35 year old man presented with a right hemiparesis and dysphasia 36 hours after abuse of Ecstasy (3,4-methylenedioxymethamphetamine). Computerized axial tomography scan demonstrated an extensive acute left cerebral infarction and carotid digital subtraction angiogram, 2 days after admission, revealed left middle cerebral artery occlusion. There were no other known risk factors and all other investigations were negative. The patient made a partial recovery. We propose an association between Ecstasy abuse and cerebral infarction. PMID:7904748
Cerebral infarction in association with Ecstasy abuse.
Manchanda, S; Connolly, M J
1993-11-01
A previously fit 35 year old man presented with a right hemiparesis and dysphasia 36 hours after abuse of Ecstasy (3,4-methylenedioxymethamphetamine). Computerized axial tomography scan demonstrated an extensive acute left cerebral infarction and carotid digital subtraction angiogram, 2 days after admission, revealed left middle cerebral artery occlusion. There were no other known risk factors and all other investigations were negative. The patient made a partial recovery. We propose an association between Ecstasy abuse and cerebral infarction.
2003-08-01
connector increased the strength of the joints by spreading the load more equally over the cross section of the wood, and in fact made the "all-wood...strength of the timber joints by spreading the load more equally over the cross section of the wood. The Timber Engineering Company established a...Laboratory Computerized Axial Tomography Columbia Broadcasting System Comprehensive Display System Corps of Engineers Ballistic Missile Construction
Mu, Zhiping; Hong, Baoming; Li, Shimin; Liu, Yi-Hwa
2009-01-01
Coded aperture imaging for two-dimensional (2D) planar objects has been investigated extensively in the past, whereas little success has been achieved in imaging 3D objects using this technique. In this article, the authors present a novel method of 3D single photon emission computerized tomography (SPECT) reconstruction for near-field coded aperture imaging. Multiangular coded aperture projections are acquired and a stack of 2D images is reconstructed separately from each of the projections. Secondary projections are subsequently generated from the reconstructed image stacks based on the geometry of parallel-hole collimation and the variable magnification of near-field coded aperture imaging. Sinograms of cross-sectional slices of 3D objects are assembled from the secondary projections, and the ordered subset expectation and maximization algorithm is employed to reconstruct the cross-sectional image slices from the sinograms. Experiments were conducted using a customized capillary tube phantom and a micro hot rod phantom. Imaged at approximately 50 cm from the detector, hot rods in the phantom with diameters as small as 2.4 mm could be discerned in the reconstructed SPECT images. These results have demonstrated the feasibility of the authors’ 3D coded aperture image reconstruction algorithm for SPECT, representing an important step in their effort to develop a high sensitivity and high resolution SPECT imaging system. PMID:19544769
Zhao, Shijie; Liu, Hui; Sun, Zhipeng; Wang, Jianwei
2017-01-01
Objective To obtain anatomical data of maxillary-zygomatic complex based on simulating the zygomatic implantation using cadaver heads and three-dimensional computerized tomography (3D-CT). Methods Simulating zygomatic implantation was performed using seven cadaver heads and 3D-CT images from forty-eight adults. After measuring the maxillary-zygomatic complex, we analyzed the position between the implantation path and the maxillary sinus cavity as well as the distance between the implantation path and the zygomatic nerve. Results The distance from the starting point to the endpoint of the implant was 56.85 ± 5.35 mm in cadaver heads and 58.15 ± 7.37 mm in 3D-CT images. For the most common implantation path (80.20%), the implant went through the maxillary sinus cavity completely. The projecting points of the implant axis (IA) on the surface of zygoma were mainly located in the region of frontal process of zygomatic bone close to the lateral orbital wall. The distances between IA and zygomatic nerve in 53 sides were shorter than 2 mm. Conclusion The simulating zygomatic implantation on cadaver skulls and 3D-CT imaging provided useful anatomical data of the maxillary-zygomatic complex. It is necessary to take care to avoid the zygomatic nerve injury during implantation, because it frequently appears on the route of implantation. PMID:29376077
Young, Michael C.; Theis, Jake R.; Hodges, James S.; Dunn, Ty B.; Pruett, Timothy L.; Chinnakotla, Srinath; Walker, Sidney P.; Freeman, Martin L.; Trikudanathan, Guru; Arain, Mustafa; Robertson, R. Paul; Wilhelm, Joshua J.; Schwarzenberg, Sarah J.; Bland, Barbara; Beilman, Gregory J.; Bellin, Melena D.
2015-01-01
Objectives About two-thirds of patients will remain on insulin therapy after total pancreatectomy with islet autotransplant (TPIAT) for chronic pancreatitis. We investigated the relationship between measured pancreas volume on computerized tomography (CT) or magnetic resonance imaging (MRI), and features of chronic pancreatiits on imaging, with subsequent islet isolation and diabetes outcomes. Methods CT or MRI was reviewed for pancreas volume (Vitrea software), and presence or absence of calcifications, atrophy, and dilated pancreatic duct in 97 patients undergoing TPIAT. Relationship between these features and: (1) islet mass isolated and (2) diabetes status at 1 year post-TPAIT were evaluated. Results Pancreas volume correlated with islet mass measured as total islet equivalents (r=0.50, p<0.0001). Mean islet equivalents was reduced by more than half if any one of calcifications, atrophy, or ductal dilatation were observed. Pancreatic calcifications increased the odds of insulin dependence 4.0 fold (1.1, 15). Collectively, the pancreas volume and 3 imaging features strongly associated with 1 year insulin use (p=0.07), islet graft failure (p=0.003), Hemoglobin A1c (p=0.0004), fasting glucose (p=0.027), and fasting C-peptide level (p=0.008). Conclusions Measures of pancreatic parenchymal destruction on imaging, including smaller pancreas volume and calcifications associate strongly with impaired islet mass and 1 year diabetes outcomes. PMID:26745861
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cover, Keith S.; Lagerwaard, Frank J.; Senan, Suresh
2006-03-01
Purpose: Four-dimensional computerized tomography scans (4DCT) enable intrafractional motion to be determined. Because more than 1500 images can be generated with each 4DCT study, tools for efficient data visualization and evaluation are needed. We describe the use of color intensity projections (CIP) for visualizing mobility. Methods: Four-dimensional computerized tomography images of each patient slice were combined into a CIP composite image. Pixels largely unchanged over the component images appear unchanged in the CIP image. However, pixels whose intensity changes over the phases of the 4DCT appear in the CIP image as colored pixels, and the hue encodes the percentage ofmore » time the tissue was in each location. CIPs of 18 patients were used to study tumor and surrogate markers, namely the diaphragm and an abdominal marker block. Results: Color intensity projections permitted mobility of high-contrast features to be quickly visualized and measured. In three selected expiratory phases ('gating phases') that were reviewed in the sagittal plane, gating would have reduced mean tumor mobility from 6.3 {+-} 2.0 mm to 1.4 {+-} 0.5 mm. Residual tumor mobility in gating phases better correlated with residual mobility of the marker block than that of the diaphragm. Conclusion: CIPs permit immediate visualization of mobility in 4DCT images and simplify the selection of appropriate surrogates for gated radiotherapy.« less
Lim, Do-Seon; Lee, In Sun; Choi, Ki-Ju; Lee, Soong Deok; Oh, Chang Seok; Kim, Yi-Suk; Bok, Gi Dae; Kim, Myeung Ju; Yi, Yang Su; Lee, Eun-Joo; Shin, Dong Hoon
2008-01-01
The socio-cultural antipathies of some descendants with regard to invasive examinations of age-old human remains make permission for dissection of Korean mummies of the Joseon Dynasty (1392–1910) difficult to obtain. Overcoming this obstacle necessitated the use of non-invasive techniques, such as multi-detector computerized tomography (MDCT) and endoscopic examination, enabling determination of the preservation status of internal organs of mummies without significantly damaging the mummies themselves. However, MDCT alone cannot clearly differentiate specific mummified organs. Therefore, in much the same way as diagnostic radiologists make their MDCT readings on living patients more reliable by means of comparison with accumulated post-factum data from autopsies or histological studies, examinations of mummies by invasive techniques should not be decried as mere destruction of age-old human remains. Rather, providing that due permission from descendants and/or other relevant authorities can be obtained, dissection and histological examination should be performed whenever opportunities arise. Therefore, in this study, we compared the radiological data acquired from a 17th century mummy with our dissection results for the same subject. As accumulation of this kind of data could be very crucial for correct interpretation of MDCT findings on Korean mummies, we will perform similar trials on other Korean mummies found in forthcoming days if conditions permit. PMID:19014355
Computerized ionospheric tomography based on geosynchronous SAR
NASA Astrophysics Data System (ADS)
Hu, Cheng; Tian, Ye; Dong, Xichao; Wang, Rui; Long, Teng
2017-02-01
Computerized ionospheric tomography (CIT) based on spaceborne synthetic aperture radar (SAR) is an emerging technique to construct the three-dimensional (3-D) image of ionosphere. The current studies are all based on the Low Earth Orbit synthetic aperture radar (LEO SAR) which is limited by long repeat period and small coverage. In this paper, a novel ionospheric 3-D CIT technique based on geosynchronous SAR (GEO SAR) is put forward. First, several influences of complex atmospheric environment on GEO SAR focusing are detailedly analyzed, including background ionosphere and multiple scattering effects (induced by turbulent ionosphere), tropospheric effects, and random noises. Then the corresponding GEO SAR signal model is constructed with consideration of the temporal-variant background ionosphere within the GEO SAR long integration time (typically 100 s to 1000 s level). Concurrently, an accurate total electron content (TEC) retrieval method based on GEO SAR data is put forward through subband division in range and subaperture division in azimuth, obtaining variant TEC value with respect to the azimuth time. The processing steps of GEO SAR CIT are given and discussed. Owing to the short repeat period and large coverage area, GEO SAR CIT has potentials of covering the specific space continuously and completely and resultantly has excellent real-time performance. Finally, the TEC retrieval and GEO SAR CIT construction are performed by employing a numerical study based on the meteorological data. The feasibility and correctness of the proposed methods are verified.
Vertebral sarcoidosis: demonstration of bone involvement by computerized axial tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dinerstein, S.L.; Kovarsky, J.
1984-08-01
A report is given of a rare case of vertebral sarcoidosis with negative conventional spinal x-ray films, yet with typical cystic lesions of the spine found incidentally during abdominal computerized axial tomography (CAT). The patient was a 28-year-old black man, who was admitted for evaluation of a 1 1/2-year history of diffuse myalgias, intermittent fever to 102 F orally, bilateral hilar adenopathy, and leukopenia. A technetium polyphosphate bone scan revealed diffuse areas of increased uptake over the sternum, entire vertebral column, and pelvis. Conventional x-ray films of the cervical, thoracic, and lumbar spine, and an AP view of the pelvismore » were all normal. Chest x-ray film revealed only bilateral hilar adenopathy. During the course of an extensive negative evaluation for infection, an abdominal CAT scan was done, showing multiple, small, sclerotic-rimmed cysts at multiple levels of the lower thoracic and lumbar spine. Bone marrow biopsy revealed only changes consistent with anemia of chronic disease. Mediastinal lymph node biopsy revealed noncaseating granulomas. A tentative diagnosis of sarcoidosis was made, and treatment with prednisone, isoniazid and rifampin was begun. Within two weeks of initiation of prednisone therapy, the patient was symptom-free. A repeat technetium polyphosphate bone scan revealed only a small residual area of mildly increased uptake over the upper thoracic vertebrae.« less
Lu, Hsueh-Kuan; Chen, Yu-Yawn; Yeh, Chinagwen; Chuang, Chih-Lin; Chiang, Li-Ming; Lai, Chung-Liang; Casebolt, Kevin M; Huang, Ai-Chun; Lin, Wen-Long; Hsieh, Kuen-Chang
2017-08-22
The aim of this study was to evaluate leg-to-leg bioelectrical impedance analysis (LBIA) using a four-contact electrode system for measuring abdominal visceral fat area (VFA). The present study recruited 381 (240 male and 141 female) Chinese participants to compare VFA measurements estimated by a standing LBIA system (VFALBIA) with computerized tomography (CT) scanned at the L4-L5 vertebrae (VFA CT ). The total mean body mass index (BMI) was 24.7 ± 4.2 kg/m 2 . Correlation analysis, regression analysis, Bland-Altman plot, and paired sample t-tests were used to analyze the accuracy of the VFA LBIA . For the total subjects, the regression line was VFA LBIA = 0.698 VFA CT + 29.521, (correlation coefficient (r) = 0.789, standard estimate of error (SEE) = 24.470 cm 2 , p < 0.001), Lin's correlation coefficient (CCC) was 0.785; and the limit of agreement (LOA; mean difference ±2 standard deviation) ranged from -43.950 to 67.951 cm 2 , LOA% (given as a percentage of mean value measured by the CT) was 48.2%. VFA LBIA and VFA CT showed significant difference (p < 0.001). Collectively, the current study indicates that LBIA has limited potential to accurately estimate visceral fat in a clinical setting.
Okabe, Teruo; Weigold, Wm Guy; Mintz, Gary S; Roswell, Robert; Joshi, Subodh; Lee, Sung Yun; Lee, Bongryeol; Steinberg, Daniel H; Roy, Probal; Slottow, Tina L Pinto; Smith, Kimberly; Torguson, Rebecca; Xue, Zhenyi; Satler, Lowell F; Kent, Kenneth M; Pichard, Augusto D; Weissman, Neil J; Lindsay, Joseph; Waksman, Ron
2008-10-15
The efficacy of contrast-enhanced multislice computed tomography (MSCT) for assessment of ambiguous lesions is unknown. We compared both quantitative coronary angiography (QCA) and MSCT to the gold standard for a significant stenosis-minimum luminal area (MLA) by intravascular ultrasound (IVUS)-in 51 patients (64 +/- 10 years old, 19 men) with 69 angiographically ambiguous, nonleft main lesions. The MSCT was performed 17 +/- 18 days before IVUS analysis. Overall diameter stenosis by QCAwas 51.0 +/- 9.8%; 39 of 51 patients (76%) eventually underwent revascularization (38 by percutaneous coronary intervention and 1 by coronary artery bypass graft). By univariate analysis, minimum luminal diameter, MLA, lumen visibility by MSCT, and minimum luminal diameter by QCA were significant predictors of MLA by IVUS
Janssen, Caroline H C; Kuijpers, Dirkjan; Vliegenthart, Rozemarijn; Overbosch, Jelle; van Dijkman, Paul R M; Zijlstra, Felix; Oudkerk, Matthijs
2005-06-01
The aim of this study was to determine whether a coronary artery calcium (CAC) score of less than 11 can reliably rule out myocardial ischemia detected by dobutamine cardiovascular magnetic resonance imaging (CMR) in patients suspected of having myocardial ischemia. In 114 of 136 consecutive patients clinically suspected of myocardial ischemia with an inconclusive diagnosis of myocardial ischemia, dobutamine CMR was performed and the CAC score was determined. The CAC score was obtained by 16-row multidetector compued tomography (MDCT) and was calculated according to the method of Agatston. The CAC score and the results of the dobutamine CMR were correlated and the positive predictive value (PPV) and the negative predictive value (NPV) of the CAC score for dobutamine CMR were calculated. A total of 114 (87%) of the patients were eligible for this study. There was a significant correlation between the CAC score and dobutamine CMR (p<0.001). Patients with a CAC score of less than 11 showed no signs of inducible ischemia during dobutamine CMR. For a CAC score of less than 101, the NPV and the PPV of the CAC score for the outcome of dobutamine CMR were, respectively, 0.96 and 0.29. In patients with an inconclusive diagnosis of myocardial ischemia a MDCT CAC score of less than 11 reliably rules out myocardial ischemia detected by dobutamine CMR.
Shaker, S B; Dirksen, A; Laursen, L C; Maltbaek, N; Christensen, L; Sander, U; Seersholm, N; Skovgaard, L T; Nielsen, L; Kok-Jensen, A
2004-07-01
To study the short-term reproducibility of lung density measurements by multi-slice computed tomography (CT) using three different radiation doses and three reconstruction algorithms. Twenty-five patients with smoker's emphysema and 25 patients with alpha1-antitrypsin deficiency underwent 3 scans at 2-week intervals. Low-dose protocol was applied, and images were reconstructed with bone, detail, and soft algorithms. Total lung volume (TLV), 15th percentile density (PD-15), and relative area at -910 Hounsfield units (RA-910) were obtained from the images using Pulmo-CMS software. Reproducibility of PD-15 and RA-910 and the influence of radiation dose, reconstruction algorithm, and type of emphysema were then analysed. The overall coefficient of variation of volume adjusted PD-15 for all combinations of radiation dose and reconstruction algorithm was 3.7%. The overall standard deviation of volume-adjusted RA-910 was 1.7% (corresponding to a coefficient of variation of 6.8%). Radiation dose, reconstruction algorithm, and type of emphysema had no significant influence on the reproducibility of PD-15 and RA-910. However, bone algorithm and very low radiation dose result in overestimation of the extent of emphysema. Lung density measurement by CT is a sensitive marker for quantitating both subtypes of emphysema. A CT-protocol with radiation dose down to 16 mAs and soft or detail reconstruction algorithm is recommended.
Ehara, Shoichi; Okuyama, Takuhiro; Shirai, Nobuyuki; Sugioka, Kenichi; Oe, Hiroki; Itoh, Toshihide; Matsuoka, Toshiyuki; Ikura, Yoshihiro; Ueda, Makiko; Naruko, Takahiko; Hozumi, Takeshi; Yoshiyama, Minoru
2009-08-01
Previous studies have shown a correlation between coronary artery cross-sectional diameter and left ventricular (LV) mass. However, no studies have examined the correlation between actual coronary artery volume (CAV) and LV mass. In the present study, measurements of CAV by 64-multislice computed tomography (MSCT) were validated and the relationship between CAV and LV mass was investigated. First, coronary artery phantoms consisting of syringes filled with solutions of contrast medium moving at simulated heart rates were scanned by 64-MSCT. Display window settings permitting accurate calculation of small volumes were optimized by evaluating volume-rendered images of the segmented contrast medium at different window settings. Next, 61 patients without significant coronary artery stenosis were scanned by 64-MSCT with the same protocol as for the phantoms. Coronary arteries were segmented on a workstation and the same window settings were applied to the volume-rendered images to calculate total CAV. Significant correlations between total CAV and LV mass (r=0.660, P<0.0001) were found, whereas an inverse relation was present between total CAV per 100 g of LV mass and LV mass. The novel concept of "CAV" for the characterization of coronary arteries may prove useful for future research, particularly on the causes of LV hypertrophy.
The vulnerable plaque: the real villain in acute coronary syndromes.
Liang, Michael; Puri, Aniket; Devlin, Gerard
2011-01-01
The term "vulnerable plaque" refers to a vascular lesion that is prone to rupture and may result in life-threatening events which include myocardial infarction. It consists of thin-cap fibroatheroma and a large lipid core which is highly thrombogenic. Acute coronary syndromes often result from rupture of vulnerable plaques which frequently are only moderately stenosed and not visible by conventional angiography. Several invasive and non-invasive strategies have been developed to assess the burden of vulnerable plaques. Intravascular ultrasound provides a two-dimensional cross-sectional image of the arterial wall and can help assess the plaque burden and composition. Optical coherent tomography offers superior resolution over intravascular ultrasound. High-resolution magnetic resonance imaging provides non-invasive imaging for visualizing fibrous cap thickness and rupture in plaques. In addition, it may be of value in assessing the effects of treatments, such as lipid-lowering therapy. Technical issues however limit its clinical applicability. The role of multi-slice computed tomography, a well established screening tool for coronary artery disease, remains to be determined. Fractional flow reserve (FFR) may provide physiological functional assessment of plaque vulnerability; however, its role in the management of vulnerable plaque requires further studies. Treatment of the vulnerable patient may involve systemic therapy which currently include statins, ACE inhibitors, beta-blockers, aspirin, and calcium-channel blockers and in the future local therapeutic options such as drug-eluting stents or photodynamic therapy.
Widmann, G; Dalla Torre, D; Hoermann, R; Schullian, P; Gassner, E M; Bale, R; Puelacher, W
2015-04-01
The influence of dose reductions on diagnostic quality using a series of high-resolution ultralow-dose computed tomography (CT) scans for computer-assisted planning and surgery including the most recent iterative reconstruction algorithms was evaluated and compared with the fracture detectability of a standard cranial emergency protocol. A human cadaver head including the mandible was artificially prepared with midfacial and orbital fractures and scanned using a 64-multislice CT scanner. The CT dose index volume (CTDIvol) and effective doses were calculated using application software. Noise was evaluated as the standard deviation in Hounsfield units within an identical region of interest in the posterior fossa. Diagnostic quality was assessed by consensus reading of a craniomaxillofacial surgeon and radiologist. Compared with the emergency protocol at CTDIvol 35.3 mGy and effective dose 3.6 mSv, low-dose protocols down to CTDIvol 1.0 mGy and 0.1 mSv (97% dose reduction) may be sufficient for the diagnosis of dislocated craniofacial fractures. Non-dislocated fractures may be detected at CTDIvol 2.6 mGy and 0.3 mSv (93% dose reduction). Adaptive statistical iterative reconstruction (ASIR) 50 and 100 reduced average noise by 30% and 56%, and model-based iterative reconstruction (MBIR) by 93%. However, the detection rate of fractures could not be improved due to smoothing effects. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Dedouit, Fabrice; Saint-Martin, Pauline; Mokrane, Fatima-Zohra; Savall, Frédéric; Rousseau, Hervé; Crubézy, Eric; Rougé, Daniel; Telmon, Norbert
2015-09-01
Virtual anthropology consists of the introduction of modern slice imaging to biological and forensic anthropology. Thanks to this non-invasive scientific revolution, some classifications and staging systems, first based on dry bone analysis, can be applied to cadavers with no need for specific preparation, as well as to living persons. Estimation of bone and dental age is one of the possibilities offered by radiology. Biological age can be estimated in clinical forensic medicine as well as in living persons. Virtual anthropology may also help the forensic pathologist to estimate a deceased person's age at death, which together with sex, geographical origin and stature, is one of the important features determining a biological profile used in reconstructive identification. For this forensic purpose, the radiological tools used are multislice computed tomography and, more recently, X-ray free imaging techniques such as magnetic resonance imaging and ultrasound investigations. We present and discuss the value of these investigations for age estimation in anthropology.
Restudy of malformations of the internal auditory meatus, cochlear nerve canal and cochlear nerve.
Li, Youjin; Yang, Jun; Liu, Jinfen; Wu, Hao
2015-07-01
The present study aims to restudy the correlation between the internal auditory meatus (IAM), the cochlear nerve canal (CNC), the cochlear nerve (CN) and inner ear malformations. In this retrospective study design, the abnormal diameter of the IAM, CNC and CN in patients with any kind of inner ear malformations was evaluated using multi-slice spiral computed tomography (MSCT) (37 patients) and magnetic resonance imaging (MRI) (18 patients). Of 37 MSCT-diagnosed patients, 2 had IAM atresia, 11 IAM stenosis, 22 enlarged IAM, and 2 normal IAM with an abnormal CN. MRI diagnoses of 18 patients revealed 8 cases of aplastic CN, 6 hypoplastic CN, and 4 normal CN. CNC stenosis was associated with CN hypoplasia (P < 0.001). Patients with absent or stenotic IAM had less CN development than those with normal or enlarged IAM (P = 0.001). We propose a modification of the existing classification systems with a view to distinguishing malformations of the IAM, CNC and CN.
Dedouit, Fabrice; Mallinger, Béatrice; Guilbeau-Frugier, Céline; Rougé, Daniel; Rousseau, Hervé; Telmon, Norbert
2011-03-20
A 3-year-old boy child died at home. The circumstances of death appeared unclear to the police investigators and a medicolegal autopsy was carried out. External examination revealed diffuse ecchymoses of varying colours. Postmortem imaging using plain X-rays and multislice computed tomography (MSCT) was performed prior to autopsy and pathological study. These investigations revealed fractures at the posterior arch of the ninth left rib. No cerebral and pericerebral traumatic lesions were diagnosed. In the abdomen, haemoperitoneum and pneumoperitoneum secondary to duodenal perforation and liver laceration were observed. At autopsy, a complete pancreatic fracture and duodenal transection were noted, accounting for the MSCT appearance. Furthermore, autopsy revealed the presence of bilateral intramuscular intercostal haemorrhages and a fracture of the eighth left rib at its posterior arch. This case report illustrates the valuable assistance rendered by MSCT as well as its limitations in diagnosing abuse when a child dies in unclear circumstances. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paschoal, Cinthia M. M.; Ferreira, Fernanda Carla L.; Santos, Luiz A. P.
The advance of multislice computed tomography (CT) has become inadequate the currently dosimetric protocol used in CT. Instead of dosimetry based on the measurement of CTDI using a pencil ion chamber of 100 m of length, it was proposed the use of a small ion chamber (IC) and the calculating the dose equilibrium (Deq) at the location of the chamber. The objective of this work was to compare the performance of a short IC and a commercial photodiode to measure the accumulated dose at the center of the scan length L, DL(0), and to obtain the equilibrium dose Deq usingmore » the two detectors. The result for L=100 mm was compared with the result of a pencil chamber. The results indicate that the commercial photodiode is suitable to measure the accumulated dose at the center of the scan length L as compared with the ion chambers. This methodology allows measurements of the accumulated dose for any desired scan length, allowing measuring the equilibrium dose Deq if the phantom is long enough to allow it. (authors)« less
3D-MSCT imaging of bullet trajectory in 3D crime scene reconstruction: two case reports.
Colard, T; Delannoy, Y; Bresson, F; Marechal, C; Raul, J S; Hedouin, V
2013-11-01
Postmortem investigations are increasingly assisted by three-dimensional multi-slice computed tomography (3D-MSCT) and have become more available to forensic pathologists over the past 20years. In cases of ballistic wounds, 3D-MSCT can provide an accurate description of the bullet location, bone fractures and, more interestingly, a clear visual of the intracorporeal trajectory (bullet track). These forensic medical examinations can be combined with tridimensional bullet trajectory reconstructions created by forensic ballistic experts. These case reports present the implementation of tridimensional methods and the results of 3D crime scene reconstruction in two cases. The authors highlight the value of collaborations between police forensic experts and forensic medicine institutes through the incorporation of 3D-MSCT data in a crime scene reconstruction, which is of great interest in forensic science as a clear visual communication tool between experts and the court. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Dyspnea in a nonagenarian: The usual suspects, an unexpected culprit.
Madeira, Sérgio; Raposo, Luís; David, Raquel; Marques, Alexandre; Andrade Gomes, José; Cardim, Nuno; Anjos, Rui
2015-09-01
Platypnea-orthodeoxia syndrome (POS) is an uncommon syndrome characterized by dyspnea and hypoxemia triggered by orthostatism and relieved by recumbency. It is often associated with an interatrial shunt through a patent foramen ovale (PFO). We report the case of a 92-year-old woman initially admitted in the setting of a traumatic femoral neck fracture (successfully treated with hip replacement surgery) in whom a reversible decline in transcutaneous oxygen saturation from 98% (in the supine position) to 84% (in the upright position) was noted early post-operatively. Thoracic multislice computed tomography excluded pulmonary embolism and severe parenchymal lung disease. The diagnosis of POS was confirmed by tilt-table contrast transesophageal echocardiography, which demonstrated a dynamic and position-dependent right-to-left shunt (torrential when semi-upright and minimal in the supine position) through a PFO. The patient underwent percutaneous closure of the PFO with an Amplatzer device, which led to prompt symptom relief and full functional recovery. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
Intersecting fractures of the skull and gunshot wounds. Case report and literature review.
Viel, Guido; Gehl, Axel; Sperhake, Jan P
2009-01-01
When two fracture lines of a solid surface (ice, glass, eggshell, etc.) intersect, it is always possible to tell which one has been made first. Indeed pre-existing damage of the surface arrests all the fracture lines produced by subsequent impacts. This well-known principle (established by Puppe in 1903) has been largely used in glass fracture analysis, but can be applied also to the examination of skull fractures. It can help sequencing blunt force or gunshot injuries determining the direction of fire and differentiating entrance from exit wounds in the absence of specific distinguishing features (i.e., internal/external beveling of the skull or overlying skin indicators). In this context, we report the case of a 76-year-old man who shot himself in the mouth with a Walther PPK 7.65 handgun and highlight the utility of the application of both Puppe's Rule and Multislice Computed Tomography (MSCT) in the examination of gunshot wounds to the skull.
Segmentation algorithm of colon based on multi-slice CT colonography
NASA Astrophysics Data System (ADS)
Hu, Yizhong; Ahamed, Mohammed Shabbir; Takahashi, Eiji; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Suzuki, Masahiro; Iinuma, Gen; Moriyama, Noriyuki
2012-02-01
CT colonography is a radiology test that looks at people's large intestines(colon). CT colonography can screen many options of colon cancer. This test is used to detect polyps or cancers of the colon. CT colonography is safe and reliable. It can be used if people are too sick to undergo other forms of colon cancer screening. In our research, we proposed a method for automatic segmentation of the colon from abdominal computed Tomography (CT) images. Our multistage detection method extracted colon and spited colon into different parts according to the colon anatomy information. We found that among the five segmented parts of the colon, sigmoid (20%) and rectum (50%) are more sensitive toward polyps and masses than the other three parts. Our research focused on detecting the colon by the individual diagnosis of sigmoid and rectum. We think it would make the rapid and easy diagnosis of colon in its earlier stage and help doctors for analysis of correct position of each part and detect the colon rectal cancer much easier.
Payabvash, Seyedmehdi; Meric, Kaan; Cayci, Zuzan
2016-01-01
To differentiate malignant from benign cervical lymph nodes in patients with head/neck cancer. In this retrospective study, 39 patients with primary head/neck cancer who underwent Positron Emission Tomography (PET)/Computerized Tomography (CT) and image-guided lymph node biopsy were included. Overall, 23 (59%) patients had biopsy-proven malignant cervical lymphadenopathy. Malignant lymph nodes had higher maximum standardized uptake (SUV-max) value (P<.001) and short-axis diameter (P=.015) compared to benign nodes. An SUV-max of ≥2.5 was 100% sensitive, and an SUV-max ≥5.5 was 100% specific for malignant lymphadenopathy. The PET/CT SUV-max value can help with differentiation of malignant cervical lymph nodes in patients with head/neck cancer. Published by Elsevier Inc.
The use of microtomography in bone tissue and biomaterial three-dimensional analysis.
Bedini, Rossella; Meleo, Deborah; Pecci, Raffaella; Pacifici, Luciano
2009-01-01
X-ray computed microtomography (micro-CT, microComputerised Tomography) is a miniaturized form of conventional computerized axial tomography (CAT ). This sophisticated technology enables 3D riconstruction of the internal structure of small X-ray opaque objects without sample destruction or preparation. The aim of this study is to show the possible applications of micro-CT in the analysis of bone graft materials of different origins (i.e. homologous, heterologous, alloplastic) in order to define their morphometric properties by means of SkyScan 1072 3D microtomography system. Since there is a close relationship between the properties of the materials and their microstructure, it is necessary to examine them using the highest levels of resolution before being able to improve existing materials or create new products.
Ott, Sabine; Gölitz, Philipp; Adamek, Edyta; Royalty, Kevin; Doerfler, Arnd; Struffert, Tobias
2015-08-01
We compared flat-detector computed tomography angiography (FD-CTA) to multislice computed tomography (MS-CTA) and digital subtracted angiography (DSA) for the visualization of experimental aneurysms treated with stents, coils or a combination of both.In 20 rabbits, aneurysms were created using the rabbit elastase aneurysm model. Seven aneurysms were treated with coils, seven with coils and stents, and six with self-expandable stents alone. Imaging was performed by DSA, MS-CTA and FD-CTA immediately after treatment. Multiplanar reconstruction (MPR) was performed and two experienced reviewers compared aneurysm/coil package size, aneurysm occlusion, stent diameters and artifacts for each modality.In aneurysms treated with stents alone, the visualization of the aneurysms was identical in all three imaging modalities. Residual aneurysm perfusion was present in two cases and visible in DSA and FD-CTA but not in MS-CTA. The diameter of coil-packages was overestimated in MS-CT by 56% and only by 16% in FD-CTA compared to DSA (p < 0.05). The diameter of stents was identical for DSA and FD-CTA and was significantly overestimated in MS-CTA (p < 0.05). Beam/metal hardening artifacts impaired image quality more severely in MS-CTA compared to FD-CTA.MS-CTA is impaired by blooming and beam/metal hardening artifacts in the visualization of implanted devices. There was no significant difference between measurements made with noninvasive FD-CTA compared to gold standard of DSA after stenting and after coiling/stent-assisted coiling of aneurysms. FD-CTA may be considered as a non-invasive alternative to the gold standard 2D DSA in selected patients that require follow up imaging after stenting. © The Author(s) 2015.
Niesterok, C; Köhler, C; Ludewig, E; Alef, M; Oechtering, G; Kiefer, I
2013-01-01
The aim of our study was to evaluate the value of projection radiography as a standard screening method for the detection of lung nodules compared to computed tomography (CT). Furthermore, we attempted to describe the reasons that might lead to a failed detection of pulmonary nodules in radiography. From dogs and cats which were diagnosed in CT (multislice CT) with nodular changes in the lung pattern we selected radiographs (projection radiography with soft copy reading) in at least two projection planes produced in the same timeframe as the CT images. Exclusion criteria were nodules > 3 cm and homogenously calcified nodules (osteomata). A total of 70 animals (50 dogs and 20 cats) met the inclusion criteria. In 43 animals (61%), nodular changes had already been detected using radiography and were then confirmed by the results of the computed tomography. In detail, 32 of 50 dogs (64%) and 11 of 20 cats (55%) showed nodular lesions in the radiographs. In cats, undetected nodules were often accompanied by highly changed lung opacities, resulting in a poor contrast of the lung. In dogs the reasons for a failed detection of lung nodules were relatively equally distributed to several causes. Interestingly, small nodule size itself was not the predominant reason for missing the nodules in radiographs. In general, radiography still plays an important role as a screening method for the detection of nodular lung lesions. However, one needs to be aware, that a quite high percentage of nodular lung changes can be missed in radiographs. The overall detection rate in this study was 61%. Furthermore, we showed that plane radiographs are of poor diagnostic value when concurrent problems exist which lead to increased lung opacity.
CT diagnosis of a clinically unsuspected acute appendicitis complicating infectious mononucleosis.
Zissin, R; Brautbar, O; Shapiro-Feinberg, M
2001-01-01
Acute appendicitis is a rare complication of infectious mononucleosis (IM). We describe a patient with IM and splenic rupture with a computerized tomography (CT) diagnosis of acute appendicitis during the acute phase of the infectious disease. Diagnostic imaging features of acute appendicitis were found on an abdominal CT performed for the evaluation of postoperative fever. Histologic examination confirmed the CT diagnosis of the clinically unsuspected acute appendicitis. Our case is unique both for the rarity of this complication and the lack of clinical symptoms.
Afzal, Samara; Nair, Amit; Grainger, Jennie; Latif, Sherif; Rehman, Atiq-ur
2010-08-01
Tender lumps in the inguinal region are often explored emergently to treat suspected hernial strangulation. We discuss the case of an adult male who presented acutely with a tender inguinal swelling and raised inflammatory markers and was therefore deemed as requiring surgical exploration. However preoperative abdominal computerized tomography (CT) revealed an extensive thrombosing congenital venous malformation of portosystemic origin with extension into the symptomatic inguinal canal. A potentially lethal exsanguination from surgery was thus avoided.
Subdural abscess secondary to covert dental sepsis
Sprott, Mae S.; Hall, K.; Newman, P. K.; Welbury, R. R.; Ingham, H. R.
1981-01-01
The bacterial flora of a subdural abscess in a 17-year-old male, with radiological evidence of unilateral infection of the maxillary and frontal air sinuses, was typical of that encountered in the dental sulcus. Extensive examination revealed no primary focus of infection other than apical infection in the 2 upper first molar teeth, which were extracted. Treatment with ampicillin, gentamicin and metronidazole rapidly controlled the subdural infection, and resolution, as evidenced by computerized tomography, was complete at 10 months. PMID:7335566
Di Vincenzo, Fabio; Carbone, Iacopo; Ottini, Laura; Profico, Antonio; Ricci, Francesca; Tafuri, Mary Anne; Fornaciari, Gino; Manzi, Giorgio
2015-01-01
The Middle Pastoral human remains from Wadi Takarkori in the Libyan Acacus mountains (Fezzan) are exceptionally preserved partial mummies ranging between 6100 and 5000 uncal years BP; this small sample represents the most ancient of its kind ever found. In this report, we present a survey of the skeletal anatomy of these mummifed corpses, based on high resolution CT-scan data, including a preliminary phenetic interpretation of their cranial morphology.
Endoscopic drainage and cystoduodedonstomy in a child with pancreatic pseudocyst.
Ateş, Ufuk; Küçük, Gönül; Çınar, Kubilay; Bahadır, Berktuğ; Bektaş, Mehmet; Göllü, Gülnur; Bingöl Koloğlu, Meltem
2017-11-01
An 11-year-old morbidly obese boy was diagnosed with pancreatic pseudocyst. Following fine needle aspiration, the cyst recurred in 1-month follow-up. Therefore, endoscopic drainage and cystoduodenostomy was performed following endosonography. Control ultrasonography (USG) revealed a completely shrunken cyst. During the 3 years of follow-up, the patient was asymptomatic with no evidence of cyst on computerized tomography scans. Endoscopic drainage and cystoduodenostomy is a minimally invasive, effective, and safe approach in the management of pancreatic pseudocysts in children.
Optimization of Brain T2 Mapping Using Standard CPMG Sequence In A Clinical Scanner
NASA Astrophysics Data System (ADS)
Hnilicová, P.; Bittšanský, M.; Dobrota, D.
2014-04-01
In magnetic resonance imaging, transverse relaxation time (T2) mapping is a useful quantitative tool enabling enhanced diagnostics of many brain pathologies. The aim of our study was to test the influence of different sequence parameters on calculated T2 values, including multi-slice measurements, slice position, interslice gap, echo spacing, and pulse duration. Measurements were performed using standard multi-slice multi-echo CPMG imaging sequence on a 1.5 Tesla routine whole body MR scanner. We used multiple phantoms with different agarose concentrations (0 % to 4 %) and verified the results on a healthy volunteer. It appeared that neither the pulse duration, the size of interslice gap nor the slice shift had any impact on the T2. The measurement accuracy was increased with shorter echo spacing. Standard multi-slice multi-echo CPMG protocol with the shortest echo spacing, also the smallest available interslice gap (100 % of slice thickness) and shorter pulse duration was found to be optimal and reliable for calculating T2 maps in the human brain.
Detecting anomalous traders using multi-slice network analysis
NASA Astrophysics Data System (ADS)
Sun, Xiao-Qian; Shen, Hua-Wei; Cheng, Xue-Qi; Zhang, Yuqing
2017-05-01
Manipulation is an important issue for both developed and emerging stock markets. Many efforts have been made to detect manipulation in stock market. However, it is still an open problem to identify the fraudulent traders, especially when they collude with each other. In this paper, we focus on the problem of identifying anomalous traders using the transaction data of 8 manipulated stocks and 42 non-manipulated stocks during a one-year period. For each stock, we construct a multi-slice trading network to characterize the daily trading behavior and the cross-day participation of each trader. Comparing the multi-slice trading network of manipulated stocks and non-manipulated stocks with their randomized version, we find that manipulated stocks exhibit high number of trader pairs that trade with each other in multiple days and high deviation from randomized network at correlation between trading frequency and trading activity. These findings are effective at distinguishing manipulated stocks from non-manipulated ones and at identifying anomalous traders.
Assessment of multislice CT to quantify pulmonary emphysema function and physiology in a rat model
NASA Astrophysics Data System (ADS)
Cao, Minsong; Stantz, Keith M.; Liang, Yun; Krishnamurthi, Ganapathy; Presson, Robert G., Jr.
2005-04-01
Purpose: The purpose of this study is to evaluate multi-slice computed tomography technology to quantify functional and physiologic changes in rats with pulmonary emphysema. Method: Seven rats were scanned using a 16-slice CT (Philips MX8000 IDT) before and after artificial inducement of emphysema. Functional parameters i.e. lung volumes were measured by non-contrast spiral scan during forced breath-hold at inspiration and expiration followed by image segmentation based on attenuation threshold. Dynamic CT imaging was performed immediately following the contrast injection to estimate physiology changes. Pulmonary perfusion, fractional blood volume, and mean transit times (MTTs) were estimated by fitting the time-density curves of contrast material using a compartmental model. Results: The preliminary results indicated that the lung volumes of emphysema rats increased by 3.52+/-1.70mL (p<0.002) at expiration and 4.77+/-3.34mL (p<0.03) at inspiration. The mean lung densities of emphysema rats decreased by 91.76+/-68.11HU (p<0.01) at expiration and low attenuation areas increased by 5.21+/-3.88% (p<0.04) at inspiration compared with normal rats. The perfusion for normal and emphysema rats were 0.25+/-0.04ml/s/ml and 0.32+/-0.09ml/s/ml respectively. The fractional blood volumes for normal and emphysema rats were 0.21+/-0.04 and 0.15+/-0.02. There was a trend toward faster MTTs for emphysema rats (0.42+/-0.08s) than normal rats (0.89+/-0.19s) with p<0.006, suggesting that blood flow crossing the capillaries increases as the capillary volume decreases and which may cause the red blood cells to leave the capillaries incompletely saturated with oxygen if the MTTs become too short. Conclusion: Quantitative measurement using CT of structural and functional changes in pulmonary emphysema appears promising for small animals.
Mori, Shinichiro; Chen, George T Y; Endo, Masahiro
2007-09-01
To analyze the water equivalent pathlength (WEL) fluctuations resulting from cardiac motion and display these variations on a beam's-eye-view image; the analysis provides insight into the accuracy of lung tumor irradiation with heavy charged particle beams. Volumetric cine computed tomography (CT) images were obtained on 7 lung cancer patients under free-breathing conditions with a 256-multislice CT scanner. Cardiac phase was determined by selecting systole and diastole. A WEL difference image (DeltaWEL) was calculated by subtracting the WEL image at end-systole from that at end-diastole at respiratory exhalation phase. Two calculation regions were defined: Region 1 was limited to the volume defined by planes bounding the heart; Region 2 included the entire body thickness for a given beam's-eye-view angle. The DeltaWEL values observed in Region 1 showed fluctuations at the periphery of the heart that varied from 20.4 (SD, 5.2) mm WEL to -15.6 (3.2) mm WEL. The areas over which these range perturbation values were observed were 36.8 (32.4) mm(2) and 6.0 (2.8) mm(2) for positive and negative WEL, respectively. The WEL fluctuations in Region 2 increased by approximately 3-4 mm WEL, whereas negative WEL fluctuations changed by approximately -4 to -5 mm WEL, compared with WEL for Region 1; areas over 20 mm WEL changes in Region 2 increased by 9 mm(2) for positive DeltaWEL and 2 mm(2) for negative DeltaWEL. Cine CT with a 256-multislice CT scanner captures both volumetric cardiac and respiratory motion with a temporal resolution sufficient to estimate range fluctuations by these motions. This information can be used to assess the range perturbations that charged particle beams may experience in irradiation of lung or esophageal tumors adjacent to the heart.
Zhao, Jin; Li, Yan; Yang, Zhi-Wei; Wang, Wei; Meng, Yan
2011-10-01
We present a case of a patient with rare anatomy of a maxillary second molar with three mesiobuccal root canals and a maxillary third molar with four separate roots, identified using multi-slice computed topography (CT) and three-dimensional reconstruction techniques. The described case enriched/might enrich our knowledge about possible anatomical aberrations of maxillary molars. In addition, we demonstrate the role of multi-slice CT as an objective tool for confirmatory diagnosis and successful endodontic management.
Experimental validation of a linear model for data reduction in chirp-pulse microwave CT.
Miyakawa, M; Orikasa, K; Bertero, M; Boccacci, P; Conte, F; Piana, M
2002-04-01
Chirp-pulse microwave computerized tomography (CP-MCT) is an imaging modality developed at the Department of Biocybernetics, University of Niigata (Niigata, Japan), which intends to reduce the microwave-tomography problem to an X-ray-like situation. We have recently shown that data acquisition in CP-MCT can be described in terms of a linear model derived from scattering theory. In this paper, we validate this model by showing that the theoretically computed response function is in good agreement with the one obtained from a regularized multiple deconvolution of three data sets measured with the prototype of CP-MCT. Furthermore, the reliability of the model as far as image restoration in concerned, is tested in the case of space-invariant conditions by considering the reconstruction of simple on-axis cylindrical phantoms.
Rianon, N J; Lang, T F; Sigurdsson, G; Eiriksdottir, G; Sigurdsson, S; Garcia, M; Pajala, S; Koster, A; Yu, B; Selwyn, B J; Taylor, W C; Kapadia, A S; Gudnason, V; Launer, L J; Harris, T B
2012-09-01
We examined if lifelong physical activity is important for maintaining bone strength in the elderly. Associations of quantitative computerized tomography-acquired bone measures (vertebral and femoral) and self-reported physical activity in mid-life (mean age, 50 years), in old age (≥65 years), and throughout life (recalled during old age) were investigated in 2,110 men and 2,682 women in the AGES-Reykjavik Study. Results conclude lifelong physical activity with continuation into old age (≥65 years) best maintains better bone health later in life. Skeletal loading is thought to modulate the loss of bone in later life, and physical activity is a chief means of affecting bone strength by skeletal loading. Despite much discussion regarding lifelong versus early adulthood physical activity for preventing bone loss later in life, inconsistency still exists regarding how to maintain bone mass later in life (≥65 years). We examined if lifelong physical activity is important for maintaining bone strength in the elderly. The associations of quantitative computerized tomography-acquired vertebral and femoral bone measures and self-reported physical activity in mid-life (mean age, 50 years), in old age (≥65 years), and throughout life (recalled during old age) were investigated in 2,110 men and 2,682 women in the AGES-Reykjavik Study. Our findings conclude that lifelong physical activity with continuation into old age (≥65 years) best maintains better bone health in the elderly.
Percutaneous nephrolithotomy in pediatric patients: is computerized tomography a must?
Gedik, Abdullah; Tutus, Ali; Kayan, Devrim; Yılmaz, Yakup; Bircan, Kamuran
2011-02-01
The aim of this study was to retrospectively evaluate the results of pediatric percutaneous nephrolithotomy (PNL) cases, and discuss the results and necessity of non-contrast computerized tomography (CT) in these cases. In all, 48 pediatric patients who underwent PNL were retrospectively evaluated. Before PNL, either intravenous urography or CT was performed. In all patients, we evaluated the PNL time, scopy time with stone burden, and complications. During the PNL procedure, we switched to open surgery in two cases: in one because of renal pelvis perforation and in the other because of transcolonic access. In one patient who was scheduled to undergo PNL, we performed open surgery, primarily because we detected a retrorenal colon with CT. The stone burden in 45 patients who underwent PNL was 445 ± 225 mm(2), the PNL time was 51 ± 23 min, and the scopy time was 6.1 ± 2.7 min. We removed nephrostomy tubes 1-4 days after the procedure. In two patients, 24 h after removal of nephrostomy tubes, we inserted double J stents because of prolonged urine extravasation from the tract. In all, 34 of the 45 patients were stone-free, 5 patients had clinically insignificant stone fragments, and 6 patients had residual stones. PNL is a safe and effective method in the treatment of pediatric patients with kidney stones. Clinical experience is the most important factor in obtaining stone-free results. CT should be performed in all pediatric patients in order to prevent colon perforation.
Gómez Palacios, Angel; Gómez Zábala, Jesús; Gutiérrez, María Teresa; Expósito, Amaya; Barrios, Borja; Zorraquino, Angel; Taibo, Miguel Angel; Iturburu, Ignacio
2006-12-01
1. To assess the sensitivity of scintigraphy using methoxy isobutyl isonitrile (MIBI). 2. To compare its resolution with that of ultrasound (US) and computerized axial tomography (CAT). 3. To use its diagnostic reliability to determine whether selective approaches can be used to treat hyperparathyroidism (HPT). A study of 76 patients who underwent surgery for HPT between 1996 and 2005 was performed. MIBI scintigraphy and cervical US were used for whole-body scanning in all patients; CAT was used in 47 patients. Intraoperative and postoperative biopsies were used for final evaluation of the tests, after visualization and surgical extirpation. The results of scintigraphy were positive in 65 patients (85.52%). The diagnosis was correct in all of the single images. Multiple images were due to hyperplasia and parathyroid adenomas with thyroid disease (5.2%). Three images, incorrectly classified as negative (3.94%), were positive. The sensitivity of US was 63% and allowed detection of three MIBI-negative adenomas (4%). CAT was less sensitive (55%), but detected a further three MIBI-negative adenomas (4%). 1. The sensitivity of MIBI reached 89.46%. In the absence of thyroid nodules, MIBI diagnosed 100% of single lesions. Pathological thyroid processes produced false-positive results (5.2%) and there were diagnostic errors (4%). 2. MIBI scintigraphy was more sensitive than US and CAT. 3. Positive, single image scintigraphy allows a selective cervical approach. US and CAT may help to save a further 8% of patients (with negative scintigraphy).
Holder, Jourdan T; Kessler, David M; Noble, Jack H; Gifford, René H; Labadie, Robert F
2018-06-01
To quantify and compare the number of cochlear implant (CI) electrodes found to be extracochlear on postoperative computerized tomography (CT) scans, the number of basal electrodes deactivated during standard CI mapping (without knowledge of the postoperative CT scan), and the extent of electrode insertion noted by the surgeon. Retrospective. Academic Medical Center. Two hundred sixty-two patients underwent standard cochlear implantation and postoperative temporal bone CT scanning. Scans were analyzed to determine the number of extracochlear electrodes. Standard CI programming had been completed without knowledge of the extracochlear electrodes identified on the CT. These standard CI maps were reviewed to record the number of deactivated basal electrodes. Lastly, each operative report was reviewed to record the extent of reported electrode insertion. 13.4% (n = 35) of CIs were found to have at least one electrode outside of the cochlea on the CT scan. Review of CI mapping indicated that audiologists had deactivated extracochlear electrodes in 60% (21) of these cases. Review of operative reports revealed that surgeons correctly indicated the number of extracochlear electrodes in 6% (2) of these cases. Extracochlear electrodes were correctly identified audiologically in 60% of cases and in surgical reports in 6% of cases; however, it is possible that at least a portion of these cases involved postoperative electrode migration. Given these findings, postoperative CT scans can provide information regarding basal electrode location, which could help improve programming accuracy, associated frequency allocation, and audibility with appropriate deactivation of extracochlear electrodes.
Staphylococcus caprae native mitral valve infective endocarditis.
Kwok, T'ng Choong; Poyner, Jennifer; Olson, Ewan; Henriksen, Peter; Koch, Oliver
2016-10-01
Staphylococcus caprae is a rare cause of infective endocarditis. Here, we report a case involving the native mitral valve in the absence of an implantable cardiac electronic device. A 76-year-old man presented with a 2 week history of confusion and pyrexia. His past medical history included an open reduction and internal fixation of a humeral fracture 17 years previously, which remained non-united despite further revision 4 years later. There was no history of immunocompromise or farm-animal contact. Two sets of blood culture bottles, more than 12 h apart, were positive for S. caprae . Trans-thoracic echocardiography revealed a 1×1.2 cm vegetation on the mitral valve, with moderate mitral regurgitation. Due to ongoing confusion, he had a magnetic resonance imaging brain scan, which showed a subacute small vessel infarct consistent with a thromboembolic source. A humeral SPECT-CT (single-photon emission computerized tomography-computerized tomography) scan showed no clear evidence of acute osteomyelitis. Surgical vegetectomy and mitral-valve repair were considered to reduce the risk of further systemic embolism and progressive valve infection. However, the potential risks of surgery to this patient led to a decision to pursue a cure with antibiotic therapy alone. He remained well 3 months after discharge, with repeat echocardiography demonstrating a reduction in the size of the vegetation (0.9 cm). Management of this infection was challenging due to its rarity and its unclear progression, complicated by the dilemma surrounding surgical intervention in a patient with a complex medical background.
Computerized tomography tailored for the assessment of microscopic hematuria.
Lang, Erich K; Macchia, Richard J; Thomas, Raju; Ruiz-Deya, Gilberto; Watson, Richard A; Richter, Frank; Irwin R, Robert; Marberger, Michael; Mydlo, Jack; Lechner, Gerhard; Cho, Kyunghee C; Gayle, Brian
2002-02-01
We report the results of a multicenter study of arterial, corticomedullary, nephrographic and excretory phase helical computerized tomography (CT) for detecting and characterizing abnormalities causing asymptomatic microscopic hematuria. We evaluated 350 consecutive patients, including 216 men and 134 women 23 to 88 years old, with asymptomatic microscopic hematuria of undetermined cause at 4 medical centers. Patients with known urological pathology were excluded from study. We performed 4 helical CT sequences, including pre-enhancement phase imaging from kidney to symphysis pubis, arterial phase imaging of the kidney and lower pelvis, corticomedullary nephrographic phase imaging of the kidney and lower pelvis, and excretory phase imaging from kidney to symphysis pubis with 2 to 5 mm. collimation and 1 to 1.5 pitch. Of 171 proved lesions 158 were correctly diagnosed. There were 10 false-positive and 13 false-negative diagnoses, indicating 0.9239 sensitivity, 0.9441 specificity, 0.9404 positive and 0.9285 negative predictive values, (p <0.001). All cases of congenital renal lesions, calculous disease, ureteral lesion and neoplastic lesion of the bladder were correctly diagnosed, as were 40 of 41 inflammatory renal, 21 of 23 renal masses and 13 of 16 inflammatory bladder lesions. In 27 patients with renal calculi the study was limited to pre-enhancement spiral CT. A positive diagnosis rate of 45.1% (158 of 350 cases) for the causes of heretofore refractory cases of hematuria with high sensitivity and specificity attest to the effectiveness of our hematuria CT protocol and support its use.
Xiao, Lin-Lin; Yang, Guoren; Chen, Jinhu; Wang, Xiaohui; Wu, Qingwei; Huo, Zongwei; Yu, Qingxi; Yu, Jinming; Yuan, Shuanghu
2017-03-15
This study aimed to find a better dosimetric parameter in predicting of radiation-induced lung toxicity (RILT) in patients with non-small cell lung cancer (NSCLC) individually: ventilation(V), perfusion (Q) or computerized tomography (CT) based. V/Q single-photon emission computerized tomography (SPECT) was performed within 1 week prior to radiotherapy (RT). All V/Q imaging data was integrated into RT planning system, generating functional parameters based on V/Q SPECT. Fifty-seven NSCLC patients were enrolled in this prospective study. Fifteen (26.3%) patients underwent grade ≥2 RILT, the remaining forty-two (73.7%) patients didn't. Q-MLD, Q-V20, V-MLD, V-V20 of functional parameters correlated more significantly with the occurrence of RILT compared to V20, MLD of anatomical parameters (r = 0.630; r = 0.644; r = 0.617; r = 0.651 vs. r = 0.424; r = 0.520 p < 0.05, respectively). In patients with chronic obstructive pulmonary diseases (COPD), V functional parameters reflected significant advantage in predicting RILT; while in patients without COPD, Q functional parameters reflected significant advantage. Analogous results were existed in fractimal analysis of global pulmonary function test (PFT). In patients with central-type NSCLC, V parameters were better than Q parameters; while in patients with peripheral-type NSCLC, the results were inverse. Therefore, this study demonstrated that choosing a suitable dosimetric parameter individually can help us predict RILT accurately.
Tombul, S T; Aki, F T; Gunay, M; Inci, K; Hazirolan, T; Karcaaltincaba, M; Erkan, I; Bakkaloglu, A; Yasavul, U; Bakkaloglu, M
2008-01-01
Digital subtract angiography is the gold standard for anatomic assessment of renal vasculature for living renal donors. However, multidetector-row computerized tomography (MDCT) is less invasive than digital subtract angiography and provides information of kidney stones and other intra-abdominal organs. In this study, preoperative MDCT angiography results were compared with the peroperative findings to evaluate the accuracy of MDCT for the evaluation of renal anatomy. From December 2002 to May 2007, all 60 consecutive living kidney donors were evaluated with MDCT angiography preoperatively. We reported the number and origin of renal arteries, presence of early branching arteries, and any intrinsic renal artery disease. Renal venous anatomy was evaluated for the presence of accessory, retroaortic, and circumaortic veins using venous phase axial images. The calyces and ureters were assessed with delayed topograms. The results of the MDCT angiography were compared with the peroperative findings. A total of 67 renal arteries were seen peroperatively in 60 renal units. Preoperative MDCT angiography detected 64 of them. The two arteries not detected by MDCT had diameters less than 3 mm. Anatomic variations were present in nine veins, five of which were detected by CT angiography. Sensitivity of MDCT angiography for arteries and veins was 95% and 93%, respectively. Positive predictive values were 100% for both arteries and veins. MDCT angiography offers a less invasive, rapid, and accurate preoperative investigation modality for vascular anatomy in living kidney donors. It also provides sufficient information about extrarenal anatomy important for donor surgery.
Janoff, Daniel M; Davol, Patrick; Hazzard, James; Lemmers, Michael J; Paduch, Darius A; Barry, John M
2004-01-01
Computerized tomography (CT) with 3-dimensional (3-D) reconstruction has gained acceptance as an imaging study to evaluate living renal donors. We report our experience with this technique in 199 consecutive patients to validate its predictions of arterial anatomy and kidney volumes. Between January 1997 and March 2002, 199 living donor nephrectomies were performed at our institution using an open technique. During the operation arterial anatomy was recorded as well as kidney weight in 98 patients and displacement volume in 27. Each donor had been evaluated preoperatively by CT angiography with 3-D reconstruction. Arterial anatomy described by a staff radiologist was compared with intraoperative findings. CT estimated volumes were reported. Linear correlation graphs were generated to assess the reliability of CT volume predictions. The accuracy of CT angiography for predicting arterial anatomy was 90.5%. However, as the number of renal arteries increased, predictive accuracy decreased. The ability of CT to predict multiple arteries remained high with a positive predictive value of 95.2%. Calculated CT volume and kidney weight significantly correlated (0.654). However, the coefficient of variation index (how much average CT volume differed from measured intraoperative volume) was 17.8%. CT angiography with 3-D reconstruction accurately predicts arterial vasculature in more than 90% of patients and it can be used to compare renal volumes. However, accuracy decreases with multiple renal arteries and volume comparisons may be inaccurate when the difference in kidney volumes is within 17.8%.
Association between gamma-glutamyltransferase and coronary artery calcification.
Atar, Asli I; Yilmaz, Omer C; Akin, Kayihan; Selcoki, Yusuf; Er, Okan; Eryonucu, Beyhan
2013-08-20
The exact mechanisms behind the association between atherosclerosis and gamma-glutamyltransferase (GGT) are unclear. Coronary artery calcification (CAC) detected by computerized tomography is an important marker of atherosclerosis and its severity correlates with coronary plaque burden. The aim of this study was to investigate if serum GGT levels are associated with CAC in patients without known coronary heart disease (CHD) who had low-intermediate risk for CHD. Two hundred and seventy two patients who had low-intermediate risk for coronary artery disease were included in the study. Serum GGT levels were measured spectrophotometrically. CACS (Agatston method) were performed using a 64-slice computerized tomography scanner. The patients were grouped according to their GGT values in four quartiles. Patients in higher GGT quartiles had elevated CAC score (P<0.001). Patients in higher GGT quartiles were predominantly males (P<0.001) and were more likely to be smoking (P=0.004), and have elevated uric acid (P<0.001), fasting blood glucose (P<0.001), CRP levels (P=0.003) and 10-year total cardiovascular risk (P=0.007) and low HDL levels (P<0.001). Positive correlations were found between log GGT and CAC (r=0.233, P<0.001). In the multivariate analysis GGT, age, smoking and serum uric acid levels appeared as independent factors predictive of presence of CAC. We demonstrated a significant correlation between serum GGT levels and CAC and CHD risk factors. Serum GGT level was an independent marker of CAC. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Variability in Cobb angle measurements using reformatted computerized tomography scans.
Adam, Clayton J; Izatt, Maree T; Harvey, Jason R; Askin, Geoffrey N
2005-07-15
Survey of intraobserver and interobserver measurement variability. To assess the use of reformatted computerized tomography (CT) images for manual measurement of coronal Cobb angles in idiopathic scoliosis. Cobb angle measurements in idiopathic scoliosis are traditionally made from standing radiographs, whereas CT is often used for assessment of vertebral rotation. Correlating Cobb angles from standing radiographs with vertebral rotations from supine CT is problematic because the geometry of the spine changes significantly from standing to supine positions, and 2 different imaging methods are involved. We assessed the use of reformatted thoracolumbar CT images for Cobb angle measurement. Preoperative CT of 12 patients with idiopathic scoliosis were used to generate reformatted coronal images. Five observers measured coronal Cobb angles on 3 occasions from each of the images. Intraobserver and interobserver variability associated with Cobb measurement from reformatted CT scans was assessed and compared with previous studies of measurement variability using plain radiographs. For major curves, 95% confidence intervals for intraobserver and interobserver variability were +/-6.6 degrees and +/-7.7 degrees, respectively. For minor curves, the intervals were +/-7.5 degrees and +/-8.2 degrees, respectively. Intraobserver and interobserver technical error of measurement was 2.4 degrees and 2.7 degrees, with reliability coefficients of 88% and 84%, respectively. There was no correlation between measurement variability and curve severity. Reformatted CT images may be used for manual measurement of coronal Cobb angles in idiopathic scoliosis with similar variability to manual measurement of plain radiographs.
Xiao, Z Y; Wang, H J; Yao, C L; Gu, G R; Xue, Y; Yin, J; Chen, J; Zhang, C; Tong, C Y; Song, Z J
2017-03-24
Objective: To explore the imaging manifestations of multi-slice spiral CT angiography (CTA) and relationship with in-hospital death in patients with aortic dissection (AD). Methods: The clinical data of 429 patients with AD who underwent CTA in Zhongshan Hospital of Fudan University between January 2009 and January 2016 were retrospectively analyzed. AD patients were divided into 2 groups, including operation group who underwent surgery or interventional therapy (370 cases) and non-operation group who underwent medical conservative treatment(59 cases). The multi-slice spiral CTA imaging features of AD were analyzed, and multivariate logistic regression analysis was used to investigate the relationship between imaging manifestations and in-hospital death in AD patients. Results: There were 12 cases (3.24%) of in-hospital death in operation group, and 28 cases (47.46%) of in-hospital death in non-operation group( P <0.001). AD involved different vascular branches. Multi-slice spiral CTA can clearly show the dissection of true and false lumen, and intimal tear was detected in 363 (84.62%) cases, outer wall calcification was revealed in 63 (14.69%) cases, and thrombus formation was present in 227 (52.91%) cases. The multivariate logistic regression analysis showed that the number of branch vessels involved ( OR =1.374, 95% CI 1.081-1.745, P =0.009) and tearing false lumen range( OR =2.059, 95% CI 1.252-3.385, P =0.004) were independent risk factors of in-hospital death in AD patients, and the number of branch vessels involved ( OR =1.600, 95% CI 1.062-2.411, P =0.025) was independent risk factor of in-hospital death in the operation group, while the tearing false lumen range ( OR =2.315, 95% CI 1.019-5.262, P =0.045) was independent risk factor of in-hospital death of non-operation group. Conclusions: Multi-slice spiral CTA can clearly show the entire AD, true and false lumen, intimal tear, wall calcification and thrombosis of AD patients. The number of branch vessels involved and tearing false lumen range are the independent risk factors of in-hospital death in AD patients.
Camera calibration for multidirectional flame chemiluminescence tomography
NASA Astrophysics Data System (ADS)
Wang, Jia; Zhang, Weiguang; Zhang, Yuhong; Yu, Xun
2017-04-01
Flame chemiluminescence tomography (FCT), which combines computerized tomography theory and multidirectional chemiluminescence emission measurements, can realize instantaneous three-dimensional (3-D) diagnostics for flames with high spatial and temporal resolutions. One critical step of FCT is to record the projections by multiple cameras from different view angles. For high accuracy reconstructions, it requires that extrinsic parameters (the positions and orientations) and intrinsic parameters (especially the image distances) of cameras be accurately calibrated first. Taking the focus effect of the camera into account, a modified camera calibration method was presented for FCT, and a 3-D calibration pattern was designed to solve the parameters. The precision of the method was evaluated by reprojections of feature points to cameras with the calibration results. The maximum root mean square error of the feature points' position is 1.42 pixels and 0.0064 mm for the image distance. An FCT system with 12 cameras was calibrated by the proposed method and the 3-D CH* intensity of a propane flame was measured. The results showed that the FCT system provides reasonable reconstruction accuracy using the camera's calibration results.
Wielpütz, Mark O.; Kauczor, Hans-Ulrich
2012-01-01
From the first measurements of the distribution of pulmonary blood flow using radioactive tracers by West and colleagues (J Clin Invest 40: 1–12, 1961) allowing gravitational differences in pulmonary blood flow to be described, the imaging of pulmonary blood flow has made considerable progress. The researcher employing modern imaging techniques now has the choice of several techniques, including magnetic resonance imaging (MRI), computerized tomography (CT), positron emission tomography (PET), and single photon emission computed tomography (SPECT). These techniques differ in several important ways: the resolution of the measurement, the type of contrast or tag used to image flow, and the amount of ionizing radiation associated with each measurement. In addition, the techniques vary in what is actually measured, whether it is capillary perfusion such as with PET and SPECT, or larger vessel information in addition to capillary perfusion such as with MRI and CT. Combined, these issues affect quantification and interpretation of data as well as the type of experiments possible using different techniques. The goal of this review is to give an overview of the techniques most commonly in use for physiological experiments along with the issues unique to each technique. PMID:22604884
Nuclear medicine in clinical neurology: an update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oldendorf, W.H.
1981-01-01
Isotope scanning using technetium 99m pertechnetate has fallen into disuse since the advent of x-ray computerized tomography. Regional brain blood flow studies have been pursued on a research basis. Increased regional blood flow during focal seizure activity has been demonstrated and is of use in localizing such foci. Cisternography as a predictive tool in normal pressure hydrocephalus is falling into disuse. Positron tomographic scanning is a potent research tool that can demonstrate both regional glycolysis and blood flow. Unfortunately, it is extremely expensive and complex to apply in a clinical setting. With support from the National Institutes of Health, sevenmore » extramural centers have been funded to develop positron tomographic capabilities, and they will greatly advance our knowledge of stroke pathophysiology, seizure disorders, brain tumors, and various degenerative diseases. Nuclear magnetic resonance imaging is a potentially valuable tool since it creates tomographic images representing the distribution of brain water. No tissue ionization is produced, and images comparable to second-generation computerized tomographic scans are already being produced in humans.« less
Vernon, Jordyn; Andruszkiewicz, Nicole; Schneider, Laura; Schieman, Colin; Finley, Christian J; Shargall, Yaron; Fahim, Christine; Farrokhyar, Forough; Hanna, Waël C
2016-11-01
In our model of comprehensive clinical staging (CCS) for lung cancer, patients with a computerized tomography scan of the chest and upper abdomen not showing distant metastases will then routinely undergo whole body positron emission tomography/computerized tomography and magnetic resonance imaging (MRI) of the brain before any therapeutic decision. Our aim was to determine the accuracy of CCS and the value of brain MRI in this population. A retrospective analysis of a prospectively entered database was performed for all patients who underwent lung cancer resection from January 2012 to June 2014. Demographics, clinical and pathological stage (seventh edition of the American Joint Committee on Cancer/Union for International Cancer Control tumor, node, and metastasis staging manual), and costs of staging were collected. Correlation between clinical and pathological stage was determined. Of 315 patients with primary lung cancer, 55.6% were female and the mean age was 70 ± 9.6 years. When correlation was analyzed without consideration for substages A and B, 49.8% of patients (158 of 315) were staged accurately, 39.7% (125 of 315) were overstaged, and 10.5% (32 of 315) were understaged. Only 4.7% of patients (15 of 315) underwent surgery without appropriate neoadjuvant treatment. Preoperative brain MRI detected asymptomatic metastases in four of 315 patients (1.3%). At a median postoperative follow-up of 19 months (range 6-43), symptomatic brain metastases developed in seven additional patients. The total cost of CCS in Canadian dollars was $367,292 over the study period, with $117,272 (31.9%) going toward brain MRI. CCS is effective for patients with resectable lung cancer, with less than 5% of patients being denied appropriate systemic treatment before surgery. Brain MRI is a low-yield and high-cost intervention in this population, and its routine use should be questioned. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.
Variable pixel size ionospheric tomography
NASA Astrophysics Data System (ADS)
Zheng, Dunyong; Zheng, Hongwei; Wang, Yanjun; Nie, Wenfeng; Li, Chaokui; Ao, Minsi; Hu, Wusheng; Zhou, Wei
2017-06-01
A novel ionospheric tomography technique based on variable pixel size was developed for the tomographic reconstruction of the ionospheric electron density (IED) distribution. In variable pixel size computerized ionospheric tomography (VPSCIT) model, the IED distribution is parameterized by a decomposition of the lower and upper ionosphere with different pixel sizes. Thus, the lower and upper IED distribution may be very differently determined by the available data. The variable pixel size ionospheric tomography and constant pixel size tomography are similar in most other aspects. There are some differences between two kinds of models with constant and variable pixel size respectively, one is that the segments of GPS signal pay should be assigned to the different kinds of pixel in inversion; the other is smoothness constraint factor need to make the appropriate modified where the pixel change in size. For a real dataset, the variable pixel size method distinguishes different electron density distribution zones better than the constant pixel size method. Furthermore, it can be non-chided that when the effort is spent to identify the regions in a model with best data coverage. The variable pixel size method can not only greatly improve the efficiency of inversion, but also produce IED images with high fidelity which are the same as a used uniform pixel size method. In addition, variable pixel size tomography can reduce the underdetermined problem in an ill-posed inverse problem when the data coverage is irregular or less by adjusting quantitative proportion of pixels with different sizes. In comparison with constant pixel size tomography models, the variable pixel size ionospheric tomography technique achieved relatively good results in a numerical simulation. A careful validation of the reliability and superiority of variable pixel size ionospheric tomography was performed. Finally, according to the results of the statistical analysis and quantitative comparison, the proposed method offers an improvement of 8% compared with conventional constant pixel size tomography models in the forward modeling.
Canella, Richard Prazeres; Adam, Guilherme Pradi; de Castillo, Roberto André Ulhôa; Codonho, Daniel; Ganev, Gerson Gandhi; de Vicenzi, Luiz Fernando
2016-01-01
Objective To correlate the angles between the acetabulum and the proximal femur in symptomatic patients with femoroacetabular impingement (FAI), using computed tomography (CT). Methods We retrospectively evaluated 103 hips from 103 patients, using multislice CT to measure the acetabular age, acetabular version (in its supraequatorial portion and in its middle third), femoral neck version, cervical-diaphyseal and alpha angles and the acetabular depth. For the statistical analysis, we used the Pearson correlation coefficient. Results There were inverse correlations between the following angles: (1) acetabular coverage versus alpha angle (p = 0.019); (2) acetabular version (supraequatorial) versus alpha angle (p = 0.049). For patients with femoral anteversion lower than 15 degrees: (1) acetabular version (supraequatorial) versus alpha angle (p = 0.026); (2) acetabular version (middle third) versus alpha angle (p = 0.02). For patients with acetabular version (supraequatorial) lower than 10 degrees: (1) acetabular version (supraequatorial) versus alpha angle (p = 0.004); (2) acetabular version (middle third) versus alpha angle (p = 0.009). Conclusion There was a statistically significant inverse correlation between the acetabular version and alpha angles (the smaller the acetabular anteversion angle was, the larger the alpha angle was) in symptomatic patients, thus supporting the hypothesis that FAI occurs when cam and pincer findings due to acetabular retroversion are seen simultaneously, and that the latter alone does not cause FAI, which leads to overdiagnosis in these cases. PMID:27069890
Canella, Richard Prazeres; Adam, Guilherme Pradi; de Castillo, Roberto André Ulhôa; Codonho, Daniel; Ganev, Gerson Gandhi; de Vicenzi, Luiz Fernando
2016-01-01
To correlate the angles between the acetabulum and the proximal femur in symptomatic patients with femoroacetabular impingement (FAI), using computed tomography (CT). We retrospectively evaluated 103 hips from 103 patients, using multislice CT to measure the acetabular age, acetabular version (in its supraequatorial portion and in its middle third), femoral neck version, cervical-diaphyseal and alpha angles and the acetabular depth. For the statistical analysis, we used the Pearson correlation coefficient. There were inverse correlations between the following angles: (1) acetabular coverage versus alpha angle (p = 0.019); (2) acetabular version (supraequatorial) versus alpha angle (p = 0.049). For patients with femoral anteversion lower than 15 degrees: (1) acetabular version (supraequatorial) versus alpha angle (p = 0.026); (2) acetabular version (middle third) versus alpha angle (p = 0.02). For patients with acetabular version (supraequatorial) lower than 10 degrees: (1) acetabular version (supraequatorial) versus alpha angle (p = 0.004); (2) acetabular version (middle third) versus alpha angle (p = 0.009). There was a statistically significant inverse correlation between the acetabular version and alpha angles (the smaller the acetabular anteversion angle was, the larger the alpha angle was) in symptomatic patients, thus supporting the hypothesis that FAI occurs when cam and pincer findings due to acetabular retroversion are seen simultaneously, and that the latter alone does not cause FAI, which leads to overdiagnosis in these cases.
Emerging imaging tools for use with traumatic brain injury research.
Hunter, Jill V; Wilde, Elisabeth A; Tong, Karen A; Holshouser, Barbara A
2012-03-01
This article identifies emerging neuroimaging measures considered by the inter-agency Pediatric Traumatic Brain Injury (TBI) Neuroimaging Workgroup. This article attempts to address some of the potential uses of more advanced forms of imaging in TBI as well as highlight some of the current considerations and unresolved challenges of using them. We summarize emerging elements likely to gain more widespread use in the coming years, because of 1) their utility in diagnosis, prognosis, and understanding the natural course of degeneration or recovery following TBI, and potential for evaluating treatment strategies; 2) the ability of many centers to acquire these data with scanners and equipment that are readily available in existing clinical and research settings; and 3) advances in software that provide more automated, readily available, and cost-effective analysis methods for large scale data image analysis. These include multi-slice CT, volumetric MRI analysis, susceptibility-weighted imaging (SWI), diffusion tensor imaging (DTI), magnetization transfer imaging (MTI), arterial spin tag labeling (ASL), functional MRI (fMRI), including resting state and connectivity MRI, MR spectroscopy (MRS), and hyperpolarization scanning. However, we also include brief introductions to other specialized forms of advanced imaging that currently do require specialized equipment, for example, single photon emission computed tomography (SPECT), positron emission tomography (PET), encephalography (EEG), and magnetoencephalography (MEG)/magnetic source imaging (MSI). Finally, we identify some of the challenges that users of the emerging imaging CDEs may wish to consider, including quality control, performing multi-site and longitudinal imaging studies, and MR scanning in infants and children.
Rérolle, Camille; Saint-Martin, Pauline; Dedouit, Fabrice; Rousseau, Hervé; Telmon, Norbert
2013-09-10
The first step in the identification process of bone remains is to determine whether they are of human or nonhuman origin. This issue may arise when only a fragment of bone is available, as the species of origin is usually easily determined on a complete bone. The present study aims to assess the validity of a morphometric method used by French forensic anthropologists to determine the species of origin: the corticomedullary index (CMI), defined by the ratio of the diameter of the medullary cavity to the total diameter of the bone. We studied the constancy of the CMI from measurements made on computed tomography images (CT scans) of different human bones, and compared our measurements with reference values selected in the literature. The measurements obtained on CT scans at three different sites of 30 human femurs, 24 tibias, and 24 fibulas were compared between themselves and with the CMI reference values for humans, pigs, dogs and sheep. Our results differed significantly from these reference values, with three exceptions: the proximal quarter of the femur and mid-fibular measurements for the human CMI, and the proximal quarter of the tibia for the sheep CMI. Mid-tibial, mid-femoral, and mid-fibular measurements also differed significantly between themselves. Only 22.6% of CT scans of human bones were correctly identified as human. We concluded that the CMI is not an effective method for determining the human origin of bone remains. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Lottering, Nicolene; MacGregor, Donna M; Alston, Clair L; Gregory, Laura S
2015-05-01
Due to disparity regarding the age at which skeletal maturation of the spheno-occipital synchondrosis occurs in forensic and biological literature, this study provides recalibrated multislice computed tomography (MSCT) age standards for the Australian (Queensland) population, using a Bayesian statistical approach. The sample comprises retrospective cranial/cervical MSCT scans obtained from 448 males and 416 females aged birth to 20 years from the Skeletal Biology and Forensic Anthropology Research Osteological Database. Fusion status of the synchondrosis was scored using a modified six-stage scoring tier on an MSCT platform, with negligible observer error (κ = 0.911 ± 0.04, intraclass correlation coefficient = 0.994). Bayesian transition analysis indicates that females are most likely to transition to complete fusion at 13.1 years and males at 15.6 years. Posterior densities were derived for each morphological stage, with complete fusion of the synchondrosis attained in all Queensland males over 16.3 years of age and females aged 13.8 years and older. The results demonstrate significant sexual dimorphism in synchondrosis fusion and are suggestive of intrapopulation variation between major geographic regions in Australia. This study contributes to the growing repository of contemporary anthropological standards calibrated for the Queensland milieu to improve the efficacy of the coronial process for medicolegal death investigation. As a stand-alone age indicator, the basicranial synchondrosis may be consulted as an exclusion criterion when determining the age of majority that constitutes 17 years in Queensland forensic practice. © 2014 Wiley Periodicals, Inc.
Collins, Sean P; Matheson, Jodi S; Hamor, Ralph E; Mitchell, Mark A; Labelle, Amber L; O'Brien, Robert T
2013-09-01
To compare the diagnostic quality of computed tomography (CT) images of normal ocular and orbital structures acquired with and without the use of general anesthesia in the cat. Eleven privately owned cats with nasal disease presenting to a single referral hospital. All cats received a complete ophthalmic examination. A 16 multislice helical CT system was utilized to acquire images of the skull and neck with and without the use of general anesthesia. Images were acquired before and after the administration of intravenous iodinated contrast. Images of normal ocular and orbital structures were evaluated via consensus by two board-certified radiologists. Visibility of ocular and orbital structures, degree of motion, and streak artifact were assessed and scored for each image set in the transverse, dorsal, and sagittal planes. The use of general anesthesia did not significantly affect the diagnostic quality of images. No motion artifact was observed in any CT image. Streak artifact was significantly increased in scans performed in the transverse orientation but not in the dorsal orientation or sagittal orientation and did not affect the diagnostic quality of the images. Contrast enhancement did not significantly enhance the visibility of any ocular or orbital structures. Diagnostic CT images of normal ocular and orbital structures can be acquired without the use of general anesthesia in the cat. © 2012 American College of Veterinary Ophthalmologists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, Marlies, E-mail: marlies.wagner@kgu.de; Kyriakou, Yiannis, E-mail: yiannis.kyriakou@siemens.com; Mesnil de Rochemont, Richard du, E-mail: mesnil@em.uni-frankfurt.de
2013-08-01
PurposeDecreased cerebral blood volume is known to be a predictor for final infarct volume in acute cerebral artery occlusion. To evaluate the predictability of final infarct volume in patients with acute occlusion of the middle cerebral artery (MCA) or the distal internal carotid artery (ICA) and successful endovascular recanalization, pooled blood volume (PBV) was measured using flat-panel detector computed tomography (FPD CT).Materials and MethodsTwenty patients with acute unilateral occlusion of the MCA or distal ACI without demarcated infarction, as proven by CT at admission, and successful Thrombolysis in cerebral infarction score (TICI 2b or 3) endovascular thrombectomy were included. Cerebralmore » PBV maps were acquired from each patient immediately before endovascular thrombectomy. Twenty-four hours after recanalization, each patient underwent multislice CT to visualize final infarct volume. Extent of the areas of decreased PBV was compared with the final infarct volume proven by follow-up CT the next day.ResultsIn 15 of 20 patients, areas of distinct PBV decrease corresponded to final infarct volume. In 5 patients, areas of decreased PBV overestimated final extension of ischemia probably due to inappropriate timing of data acquisition and misery perfusion.ConclusionPBV mapping using FPD CT is a promising tool to predict areas of irrecoverable brain parenchyma in acute thromboembolic stroke. Further validation is necessary before routine use for decision making for interventional thrombectomy.« less
Localization accuracy of sphere fiducials in computed tomography images
NASA Astrophysics Data System (ADS)
Kobler, Jan-Philipp; Díaz Díaz, Jesus; Fitzpatrick, J. Michael; Lexow, G. Jakob; Majdani, Omid; Ortmaier, Tobias
2014-03-01
In recent years, bone-attached robots and microstereotactic frames have attracted increasing interest due to the promising targeting accuracy they provide. Such devices attach to a patient's skull via bone anchors, which are used as landmarks during intervention planning as well. However, as simulation results reveal, the performance of such mechanisms is limited by errors occurring during the localization of their bone anchors in preoperatively acquired computed tomography images. Therefore, it is desirable to identify the most suitable fiducials as well as the most accurate method for fiducial localization. We present experimental results of a study focusing on the fiducial localization error (FLE) of spheres. Two phantoms equipped with fiducials made from ferromagnetic steel and titanium, respectively, are used to compare two clinically available imaging modalities (multi-slice CT (MSCT) and cone-beam CT (CBCT)), three localization algorithms as well as two methods for approximating the FLE. Furthermore, the impact of cubic interpolation applied to the images is investigated. Results reveal that, generally, the achievable localization accuracy in CBCT image data is significantly higher compared to MSCT imaging. The lowest FLEs (approx. 40 μm) are obtained using spheres made from titanium, CBCT imaging, template matching based on cross correlation for localization, and interpolating the images by a factor of sixteen. Nevertheless, the achievable localization accuracy of spheres made from steel is only slightly inferior. The outcomes of the presented study will be valuable considering the optimization of future microstereotactic frame prototypes as well as the operative workflow.
[Virtual otoscopy--technique, indications and initial experiences with multislice spiral CT].
Klingebiel, R; Bauknecht, H C; Lehmann, R; Rogalla, P; Werbs, M; Behrbohm, H; Kaschke, O
2000-11-01
We report the standardized postprocessing of high-resolution CT data acquired by incremental CT and multi-slice CT in patients with suspected middle ear disorders to generate three-dimensional endoluminal views known as virtual otoscopy. Subsequent to the definition of a postprocessing protocol, standardized endoluminal views of the middle ear were generated according to their otological relevance. The HRCT data sets of 26 ENT patients were transferred to a workstation and postprocessed to 52 virtual otoscopies. Generation of predefined endoluminal views from the HRCT data sets was possible in all patients. Virtual endoscopic views added meaningful information to the primary cross-sectional data in patients suffering from ossicular pathology, having contraindications for invasive tympanic endoscopy or being assessed for surgery of the tympanic cavity. Multi slice CT improved the visualization of subtle anatomic details such as the stapes suprastructure and reduced the scanning time. Virtual endoscopy allows for the non invasive endoluminal visualization of various tympanic lesions. Use of the multi-slice CT technique reduces the scanning time and improves image quality in terms of detail resolution.
Scripes, Paola G; Yaparpalvi, Ravindra
2012-09-01
The usage of functional data in radiation therapy (RT) treatment planning (RTP) process is currently the focus of significant technical, scientific, and clinical development. Positron emission tomography (PET) using ((18)F) fluorodeoxyglucose is being increasingly used in RT planning in recent years. Fluorodeoxyglucose is the most commonly used radiotracer for diagnosis, staging, recurrent disease detection, and monitoring of tumor response to therapy (Lung Cancer 2012;76:344-349; Lung Cancer 2009;64:301-307; J Nucl Med 2008;49:532-540; J Nucl Med 2007;48:58S-67S). All the efforts to improve both PET and computed tomography (CT) image quality and, consequently, lesion detectability have a common objective to increase the accuracy in functional imaging and thus of coregistration into RT planning systems. In radiotherapy, improvement in target localization permits reduction of tumor margins, consequently reducing volume of normal tissue irradiated. Furthermore, smaller treated target volumes create the possibility of dose escalation, leading to increased chances of tumor cure and control. This article focuses on the technical aspects of PET/CT image acquisition, fusion, usage, and impact on the physics of RTP. The authors review the basic elements of RTP, modern radiation delivery, and the technical parameters of coregistration of PET/CT into RT computerized planning systems. Copyright © 2012 Elsevier Inc. All rights reserved.
Relatively Long Survival in Hepatocellular Carcinoma Presenting With Carcinoid Syndrome
Nwokediuko, Sylvester Chuks; Uchenna, Ijoma; Esther, Ofoegbu; Okechukwu, Okafor; Augustine, Onuh; Charity, Ajuyah
2010-01-01
Hepatocelluar carcinoma is one of the commonest cancers in Nigeria. Some patients may manifest a variety of paraneoplastic syndromes. Carcinoid syndrome is an extremely rare presentation of hepatocellular carcinoma. A 57-year old man presented with recurrent facial flushing and diarrhea, tricuspid regurgitation, and very high level of urinary hydroxyindoleacetic acid (HIAA) as the first manifestation of a multicentric hepatic lesion which proved histologically to be hepatocellular carcinoma. The lesions also exhibited arterial hypervascularization on contrast enhanced computerized tomography. The patient is still alive after 6 years of symptoms. PMID:27956985
A case report of a spontaneous oesophageal pleural fistula.
Kumar, Sanjeev; Singh, Arshdeep; Matreja, Prithpal S; Kler, Sanjiv Kumar
2013-03-01
We are reporting a case of an asthmatic patient who presented to us with retrosternal chest pain, constipation, and shortness of breath, with features which were suggestive of a hydropneumothorax and shock. On recovery from the shock, the patient was found to have increased chest tube drainage, which was suggestive of an oesophageal rupture. The Computerized Tomography (CT) scan showed a fistulous track. The patient was diagnosed as a case of a spontaneous oesophageal pleural fistula (Spontaneous EPF) on the basis of her clinical and radiological findings.
A Case Report of a Spontaneous Oesophageal Pleural Fistula
Kumar, Sanjeev; Singh, Arshdeep; Matreja, Prithpal S; Kler, Sanjiv Kumar
2013-01-01
We are reporting a case of an asthmatic patient who presented to us with retrosternal chest pain, constipation, and shortness of breath, with features which were suggestive of a hydropneumothorax and shock. On recovery from the shock, the patient was found to have increased chest tube drainage, which was suggestive of an oesophageal rupture. The Computerized Tomography (CT) scan showed a fistulous track. The patient was diagnosed as a case of a spontaneous oesophageal pleural fistula (Spontaneous EPF) on the basis of her clinical and radiological findings. PMID:23634410
Xeroradiography and ultrasonography in the evaluation of a penile injury.
Oesterling, J E; Bromberg, W D; Albertsen, P C
1986-04-01
A 34-year-old white man presented with severe penile cellulitis following injection of epoxy glue into the shaft of the penis. Preoperative xeroradiography and ultrasonography localized the hardened masses of glue to the left corpus cavernosum and subcutaneous tissues. Under the guidance of intraoperative ultrasonography this foreign material was removed surgically. Postoperatively, the cellulitis resolved promptly and xeroradiography demonstrated no residual fragments. Although various modalities, including computerized tomography and roentgenography, are available to detect foreign bodies in soft tissues, xeroradiography and ultrasonography are ideally suited for use in the male external genitalia.
Current Trends in the Management of Blunt Solid Organ Injuries.
Taviloglu, Korhan; Yanar, Hakan
2009-04-01
The management of patients with solid organ injuries has changed since the introduction of technically advanced imaging tools, such as ultrasonography and multiple scan computerized tomography, interventional radiological techniques and modern intensive care units. In spite of this development in the management of these patients, major solid organ traumas can still be challenging. There has been great improvement in the non-operative management (NOM) of intra-abdominal solid organ injury in recent decades. In most cases treatment of injuries has shifted from early surgical treatment to NOM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willerson, J.T.
1979-01-01
Nuclear Cardiology is a well-written, concise compendium of chapters that covers a wide range of topics in nuclear cardiology. Each chapter has been contributed by one or more recognized experts in the field, and the work is thoroughly referened. The physics and physiology of nuclear cardiology, myocardial imaging with /sup 201/Tl and /sup 99m/Tc pyrophosphate, left ventricular and right ventricular function, measurement of coronary blood flow with /sup 133/Xe, and microspheres are discussed, and there are chapters on metabolic imaging with positron emitters and on transmission computerized tomography of the heart.
Neural network and its application to CT imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nikravesh, M.; Kovscek, A.R.; Patzek, T.W.
We present an integrated approach to imaging the progress of air displacement by spontaneous imbibition of oil into sandstone. We combine Computerized Tomography (CT) scanning and neural network image processing. The main aspects of our approach are (I) visualization of the distribution of oil and air saturation by CT, (II) interpretation of CT scans using neural networks, and (III) reconstruction of 3-D images of oil saturation from the CT scans with a neural network model. Excellent agreement between the actual images and the neural network predictions is found.
Nuclear magnetic resonance diagnosis of an anaplastic astrocytoma.
Jackson, J A; Derman, H S; Harper, R L; Willcott, M R; Ford, J J; Schneiders, N J; McCrary, J A; Kelly, A; Bryan, R N
1984-01-01
A patient presented with an 8-month history of a progressive left homonymous visual field deficit, left hemiparesis, and a left thalamocortical sensory deficit that was not detectable by repeated conventional neurodiagnostic evaluations. Proton nuclear magnetic resonance (NMR) imaging revealed a right parietal lesion characterized by a prolonged T2 (spin-spin relaxation time). At surgery, the mass proved to be an anaplastic astrocytoma. NMR appears to be more sensitive than x-ray computerized tomography scanning in some patients with malignant gliomas and offers the clinician an additional probe with which to evaluate these patients.
Appendiceal hemorrhage -- an uncommon cause of lower gastrointestinal bleeding.
Chiang, Ching-Chung; Tu, Chi-Wen; Liao, Chi-Szu; Shieh, Min-Chieh; Sung, Tien-Chou
2011-06-01
Lower gastrointestinal bleeding is a common disease among elderly patients. The common sources of lower gastrointestinal bleeding include vascular disease, Crohn's disease, neoplasms, inflammatory bowel disease, hemorrhoids, and ischemic colitis. Lower gastrointestinal bleeding arising from the appendix is an extremely rare condition. We report a case of appendiceal hemorrhage in a young male. Diagnosis was made by multidetector computerized tomography during survey for hematochezia. The patient recovered well after appendectomy. The histological finding revealed focal erosion of appendix mucosa with bleeding. Copyright © 2011. Published by Elsevier B.V.
Hepatic CT image query using Gabor features
NASA Astrophysics Data System (ADS)
Zhao, Chenguang; Cheng, Hongyan; Zhuang, Tiange
2004-07-01
A retrieval scheme for liver computerize tomography (CT) images based on Gabor texture is presented. For each hepatic CT image, we manually delineate abnormal regions within liver area. Then, a continuous Gabor transform is utilized to analyze the texture of the pathology bearing region and extract the corresponding feature vectors. For a given sample image, we compare its feature vector with those of other images. Similar images with the highest rank are retrieved. In experiments, 45 liver CT images are collected, and the effectiveness of Gabor texture for content based retrieval is verified.
An interesting case of angiogenesis in cavernous hemangioma.
Das, Dipankar; Bhattacharjee, Kasturi; Deka, Panna; Bhattacharjee, Harsha; Misra, Diva Kant; Koul, Akanksha; Kapoor, Deepika; Deka, Apurba
2016-10-01
Cavernous hemangioma is the most common orbital tumor in adult. There is lot of literatures for clinicopathological features of this tumor. These tumors had been studied for the model of angiogenesis in many of the experimental setups. We present a case of 34-year-old male with this tumor in the left eye with computerized tomography evidence. Postsurgical laboratory findings gave interesting evidence of tumor angiogenesis with tumor endothelial cells and sprouting of the small vessels endothelial cells. Podosome rosette could be conceptualized from the characteristic patterns seen in the tumor.
Unified Digital Image Display And Processing System
NASA Astrophysics Data System (ADS)
Horii, Steven C.; Maguire, Gerald Q.; Noz, Marilyn E.; Schimpf, James H.
1981-11-01
Our institution like many others, is faced with a proliferation of medical imaging techniques. Many of these methods give rise to digital images (e.g. digital radiography, computerized tomography (CT) , nuclear medicine and ultrasound). We feel that a unified, digital system approach to image management (storage, transmission and retrieval), image processing and image display will help in integrating these new modalities into the present diagnostic radiology operations. Future techniques are likely to employ digital images, so such a system could readily be expanded to include other image sources. We presently have the core of such a system. We can both view and process digital nuclear medicine (conventional gamma camera) images, positron emission tomography (PET) and CT images on a single system. Images from our recently installed digital radiographic unit can be added. Our paper describes our present system, explains the rationale for its configuration, and describes the directions in which it will expand.
Rothschild, Bruce M
2014-03-01
Paravertebral osseous masses in reptiles have been attributed to Paget's disease on the basis of histology. Histologically recognized mosaic architecture and cement lines, however, lack specificity. A Varanus dorianus with this condition was subjected to standard and computerized tomography. Because the masses were extraskeletal in nature, Paget's disease could be excluded. Although interpretation of the computed tomography suggested the process to be entirely extraskeletal, standard radiographs revealed disorganized vertebral architecture characteristic of osteomyelitis, crossing intervertebral spaces. Posttraumatic myositis ossificans and calcified hematoma were confidently excluded as diagnoses. The etiology of paraspinal masses in this V. dorianus appears attributable to infection, with infection of a puncture wound hypothesized as the underlying process. If one extrapolates the findings in this one animal, it seems reasonable to suggest that consideration be given to investigating the possibility of an infectious origin when similar masses are recognized in other reptiles.
Early Diagnosis of Breast Cancer.
Wang, Lulu
2017-07-05
Early-stage cancer detection could reduce breast cancer death rates significantly in the long-term. The most critical point for best prognosis is to identify early-stage cancer cells. Investigators have studied many breast diagnostic approaches, including mammography, magnetic resonance imaging, ultrasound, computerized tomography, positron emission tomography and biopsy. However, these techniques have some limitations such as being expensive, time consuming and not suitable for young women. Developing a high-sensitive and rapid early-stage breast cancer diagnostic method is urgent. In recent years, investigators have paid their attention in the development of biosensors to detect breast cancer using different biomarkers. Apart from biosensors and biomarkers, microwave imaging techniques have also been intensely studied as a promising diagnostic tool for rapid and cost-effective early-stage breast cancer detection. This paper aims to provide an overview on recent important achievements in breast screening methods (particularly on microwave imaging) and breast biomarkers along with biosensors for rapidly diagnosing breast cancer.
Soriano, Enrique; Plazzotta, Fernando; Campos, Fernando; Kaminker, Diego; Cancio, Alfredo; Aguilera Díaz, Jerónimo; Luna, Daniel; Seehaus, Alberto; Carcía Mónaco, Ricardo; de Quirós, Fernán González Bernaldo
2010-01-01
Every single piece of healthcare information should be fully integrated and transparent within the electronic health record. The Italian Hospital of Buenos Aires initiated the project Multimedia Health Record with the goal to achieve this integration while maintaining a holistic view of current structure of the systems of the Hospital, where the axis remains are the patient and longitudinal history, commencing with section Computed Tomography. Was implemented DICOM standard for communication and image storage and bought a PACS. It was necessary adapt our generic reporting system for live up to the commercial RIS. The Computerized Tomography (CT) Scanners of our hospital were easily integrated into the DICOM network and all the CT Scans generated by our radiology service were stored in the PACS, reported using the Structured Reporting System (we installed diagnostic terminals equipped with 3 monitors) and displayed in the EHR at any point of HIBA's healthcare network.
Shah, T; Verdile, G; Sohrabi, H; Campbell, A; Putland, E; Cheetham, C; Dhaliwal, S; Weinborn, M; Maruff, P; Darby, D; Martins, R N
2014-12-02
Physical exercise interventions and cognitive training programs have individually been reported to improve cognition in the healthy elderly population; however, the clinical significance of using a combined approach is currently lacking. This study evaluated whether physical activity (PA), computerized cognitive training and/or a combination of both could improve cognition. In this nonrandomized study, 224 healthy community-dwelling older adults (60-85 years) were assigned to 16 weeks home-based PA (n=64), computerized cognitive stimulation (n=62), a combination of both (combined, n=51) or a control group (n=47). Cognition was assessed using the Rey Auditory Verbal Learning Test, Controlled Oral Word Association Test and the CogState computerized battery at baseline, 8 and 16 weeks post intervention. Physical fitness assessments were performed at all time points. A subset (total n=45) of participants underwent [(18)F] fluorodeoxyglucose positron emission tomography scans at 16 weeks (post-intervention). One hundred and ninety-one participants completed the study and the data of 172 participants were included in the final analysis. Compared with the control group, the combined group showed improved verbal episodic memory and significantly higher brain glucose metabolism in the left sensorimotor cortex after controlling for age, sex, premorbid IQ, apolipoprotein E (APOE) status and history of head injury. The higher cerebral glucose metabolism in this brain region was positively associated with improved verbal memory seen in the combined group only. Our study provides evidence that a specific combination of physical and mental exercises for 16 weeks can improve cognition and increase cerebral glucose metabolism in cognitively intact healthy older adults.
Shah, T; Verdile, G; Sohrabi, H; Campbell, A; Putland, E; Cheetham, C; Dhaliwal, S; Weinborn, M; Maruff, P; Darby, D; Martins, R N
2014-01-01
Physical exercise interventions and cognitive training programs have individually been reported to improve cognition in the healthy elderly population; however, the clinical significance of using a combined approach is currently lacking. This study evaluated whether physical activity (PA), computerized cognitive training and/or a combination of both could improve cognition. In this nonrandomized study, 224 healthy community-dwelling older adults (60–85 years) were assigned to 16 weeks home-based PA (n=64), computerized cognitive stimulation (n=62), a combination of both (combined, n=51) or a control group (n=47). Cognition was assessed using the Rey Auditory Verbal Learning Test, Controlled Oral Word Association Test and the CogState computerized battery at baseline, 8 and 16 weeks post intervention. Physical fitness assessments were performed at all time points. A subset (total n=45) of participants underwent [18F] fluorodeoxyglucose positron emission tomography scans at 16 weeks (post-intervention). One hundred and ninety-one participants completed the study and the data of 172 participants were included in the final analysis. Compared with the control group, the combined group showed improved verbal episodic memory and significantly higher brain glucose metabolism in the left sensorimotor cortex after controlling for age, sex, premorbid IQ, apolipoprotein E (APOE) status and history of head injury. The higher cerebral glucose metabolism in this brain region was positively associated with improved verbal memory seen in the combined group only. Our study provides evidence that a specific combination of physical and mental exercises for 16 weeks can improve cognition and increase cerebral glucose metabolism in cognitively intact healthy older adults. PMID:25463973
Hemsley, S; Palmer, H; Canfield, R B; Stewart, M E B; Krockenberger, M B; Malik, R
2013-09-01
To use cross-sectional imaging (helical computed tomography (CT)) combined with conventional anatomical dissection to define the normal anatomy of the nasal cavity and bony cavitations of the koala skull. Helical CT scans of the heads of nine adult animals were obtained using a multislice scanner acquiring thin slices reconstructed in the transverse, sagittal and dorsal planes. Subsequent anatomical dissection permitted confirmation of correct identification and further delineation of bony and air-filled structures visible in axial and multiplanar reformatted CT images. The nasal cavity was relatively simple, with little scrolling of nasal conchae, but bony cavitations were complex and extensive. A rostral maxillary recess and ventral conchal, caudal maxillary, frontal and sphenoidal paranasal sinuses were identified and characterised. Extensive temporal bone cavitation was shown to be related to a large epitympanic recess. The detailed anatomical data provided are applicable to future functional and comparative anatomical studies, as well as providing a preliminary atlas for clinical investigation of conditions such as cryptococcal rhinosinusitis, a condition more common in the koala than in many other species. © 2013 Australian Veterinary Association.
Uncovered secret of a Vasseur-Tramond wax model.
Pastor, J F; Gutiérrez, B; Montes, J M; Ballestriero, R
2016-01-01
The technique of anatomical wax modelling reached its heyday in Italy during the 18th century, through a fruitful collaboration between sculptors and anatomists. It soon spread to other countries, and prestigious schools were created in England, France, Spain and Austria. Paris subsequently replaced Italy as the major centre of manufacture, and anatomical waxes were created there from the mid-19th century in workshops such as that of Vasseur-Tramond. This workshop began to sell waxes to European Faculties of Medicine and Schools of Surgery around 1880. Little is known of the technique employed in the creation of such artefacts as this was deemed a professional secret. To gain some insight into the methods of construction, we have studied a Vasseur-Tramond wax model in the Valladolid University Anatomy Museum, Spain, by means of multi-slice computerised tomography and X-ray analysis by means of environmental scanning electron microscopy. Scanning electron microscopy was used to examine the hair. These results have revealed some of the methods used to make these anatomical models and the materials employed. © 2015 Anatomical Society.
Bonello, L; Armero, S; Jacquier, A; Com, O; Sarran, A; Sbragia, P; Panuel, M; Arques, S; Paganelli, F
2009-05-01
Among patients admitted in the emergency department for acute atypical chest pain those with an acute coronary syndrome (ACS) who are mistakenly discharged home have high mortality. A recent retrospective study has demonstrated that multislice computed tomography (MSCT) coronary angiography could improve triage of these patients. We aimed to prospectively confirm these data on patients with a negative screening including maximal treadmill stress. 30 patients discharged from the emergency department after negative screening for an ACS were included. All patients underwent MSCT angiography of the coronary artery. Patients with coronary atheroma on MSCT had an invasive coronary angiography to confirm these findings. Seven patients (23%) had obstructive coronary artery disease on MSCT. Invasive coronary angiography (ICA) confirmed the diagnosis in all patients. In patients with no previously known coronary artery disease admitted to the emergency department with atypical acute chest pain and discharged after negative screening, including maximal treadmill stress test, MSCT coronary angiography is useful for the diagnosis of obstructive coronary artery disease.
Nie, Ping; Zhu, Min; Lu, Xiao-Feng; Fang, Bing
2013-05-01
Severe obstructive sleep apnea syndrome (OSAS) threatens patients' lives. To solve ventilation problem, snoring, and avoid another orthognathic surgery for mandibular advancement, bone-anchored rapid maxillary expansion and bilateral interoral mandibular distraction osteogenesis were tried on a 20-year-old Chinese male patient with severe skeletal class II malocclusion and OSAS.The patient had polysomnography (apnea-hypopnea index 54.2), body mass index measurement (19.7 kg/m), and cephalometry before the treatment. Bone-anchored rapid maxillary expansion was performed for the correction of maxillary transverse and minor sagittal deficiency and the improvement of nasal airflow by decreasing nasal resistance. Bilateral interoral mandibular distraction osteogenesis was operated to lengthen the small, retruded mandible by 15 mm. Orthodontic treatment after the maxillary expansion and mandibular distraction osteogenesis can help obtain stable occlusion.The Epworth Sleepiness Scale, a questionnaire for temporomandibular joint, cephalometric analysis, polysomnography, acoustic rhinometry, and multislice spiral computed tomography were performed to evaluate changes from the treatment. All the results showed that the patient had a significantly alleviated OSAS. In addition, an acceptable occlusion was also obtained.
Magnetic resonance imaging of the nose and paranasal sinuses.
Lloyd, G A
1989-01-01
Seventy-five patients with a wide range of sinus disease have been investigated by magnetic resonance (MR): these included congenital conditions, allergic and inflammatory sinus disease, fungus infections, and the necrotizing granulomata. In addition, a variety of benign and malignant tumours have been examined, and in the more recent sinus malignancies the paramagnetic contrast agent, Gadolinium (Gd) DTPA (Schering Health Care) has been used. This experience of magnetic resonance scanning has shown that it is superior to computed tomography in demonstrating the extent of malignant disease in the nose and sinuses; most especially when Gd DTPA is used, reaching an accuracy of over 96% by biopsy correlation. An additional advantage of this technique is the wide coverage of the head and neck for the assessment of malignant disease, provided by direct 3 plane imaging and the multislice facility. The main disadvantage of magnetic resonance of the sinuses is the poor demonstration of calcification and bone. For this reason the MR scans may need to be augmented by high resolution CT performed specifically to show bone detail. Images Figure 2. Figure 3. PMID:2926770
3D Imaging with Holographic Tomography
NASA Astrophysics Data System (ADS)
Sheppard, Colin J. R.; Kou, Shan Shan
2010-04-01
There are two main types of tomography that enable the 3D internal structures of objects to be reconstructed from scattered data. The commonly known computerized tomography (CT) give good results in the x-ray wavelength range where the filtered back-projection theorem and Radon transform can be used. These techniques rely on the Fourier projection-slice theorem where rays are considered to propagate straight through the object. Another type of tomography called `diffraction tomography' applies in applications in optics and acoustics where diffraction and scattering effects must be taken into account. The latter proves to be a more difficult problem, as light no longer travels straight through the sample. Holographic tomography is a popular way of performing diffraction tomography and there has been active experimental research on reconstructing complex refractive index data using this approach recently. However, there are two distinct ways of doing tomography: either by rotation of the object or by rotation of the illumination while fixing the detector. The difference between these two setups is intuitive but needs to be quantified. From Fourier optics and information transformation point of view, we use 3D transfer function analysis to quantitatively describe how spatial frequencies of the object are mapped to the Fourier domain. We first employ a paraxial treatment by calculating the Fourier transform of the defocused OTF. The shape of the calculated 3D CTF for tomography, by scanning the illumination in one direction only, takes on a form that we might call a 'peanut,' compared to the case of object rotation, where a diablo is formed, the peanut exhibiting significant differences and non-isotropy. In particular, there is a line singularity along one transverse direction. Under high numerical aperture conditions, the paraxial treatment is not accurate, and so we make use of 3D analytical geometry to calculate the behaviour in the non-paraxial case. This time, we obtain a similar peanut, but without the line singularity.
Rude, Robert K; Gruber, Helen E; Norton, H James; Wei, Livia Y; Frausto, Angelica; Kilburn, Jeremy
2005-08-01
Low dietary magnesium (Mg) may be a risk factor for osteoporosis. In animals, severe Mg deficiency (0.04% of nutrient requirement [NR]) results in bone loss. We have also found that a more moderate dietary Mg restriction (10% of NR) also resulted in loss of bone. We now report the effect of Mg intake of 25% NR on bone and mineral metabolism in the rat. Serum Mg, Ca, PTH, 1,25(OH)2-vitamin D, alkaline phosphatase, osteocalcin, and pyridinoline were measured at 2, 4, and 6 months in control and Mg-deficient animals. Femurs and tibias were collected for mineral content, micro-computerized tomography, histomorphometry, and immunocytochemical localization. Profound Mg deficiency developed as assessed by marked hypomagnesemia and 27% reduction in bone Mg content. Serum calcium was not significantly different between groups. Mg depletion resulted in a significantly lower serum PTH concentrations. Serum 1,25(OH)2-vitamin D was also significantly lower. No difference was noted in markers of bone turnover. Histomorphometry and micro-computerized tomography demonstrated decreased bone volume and trabecular thickness. No difference was observed for osteoclast or osteoblast number. Inflammatory cytokines may contribute to bone loss. We found that immunocytochemical localization of TNFalpha in osteoclasts was increased 138-150%. This increase in TNFalpha may be due to increased substance P as it was found to be elevated from 179% to 432%. These data demonstrate that Mg intake of 25% NR in the rat causes lower bone mass which may be related to increased release of substance P and TNFalpha.
Ahmad, Mansur; Hollender, Lars; Anderson, Quentin; Kartha, Krishnan; Ohrbach, Richard; Truelove, Edmond L; John, Mike T; Schiffman, Eric L
2009-06-01
As part of the Multisite Research Diagnostic Criteria For Temporomandibular Disorders (RDC/TMD) Validation Project, comprehensive temporomandibular joint diagnostic criteria were developed for image analysis using panoramic radiography, magnetic resonance imaging (MRI), and computerized tomography (CT). Interexaminer reliability was estimated using the kappa (kappa) statistic, and agreement between rater pairs was characterized by overall, positive, and negative percent agreement. Computerized tomography was the reference standard for assessing validity of other imaging modalities for detecting osteoarthritis (OA). For the radiologic diagnosis of OA, reliability of the 3 examiners was poor for panoramic radiography (kappa = 0.16), fair for MRI (kappa = 0.46), and close to the threshold for excellent for CT (kappa = 0.71). Using MRI, reliability was excellent for diagnosing disc displacements (DD) with reduction (kappa = 0.78) and for DD without reduction (kappa = 0.94) and good for effusion (kappa = 0.64). Overall percent agreement for pairwise ratings was >or=82% for all conditions. Positive percent agreement for diagnosing OA was 19% for panoramic radiography, 59% for MRI, and 84% for CT. Using MRI, positive percent agreement for diagnoses of any DD was 95% and of effusion was 81%. Negative percent agreement was >or=88% for all conditions. Compared with CT, panoramic radiography and MRI had poor and marginal sensitivity, respectively, but excellent specificity in detecting OA. Comprehensive image analysis criteria for the RDC/TMD Validation Project were developed, which can reliably be used for assessing OA using CT and for disc position and effusion using MRI.
Huo, Jun; Liu, Zhong-Yuan; Wang, Ke-Feng; Xu, Zhen-Qun
2015-09-01
This study was conducted to evaluate the chemical composition of eight types of urinary calculi using spiral computerized tomography (CT) in vivo. From October 2011 to February 2013, upper urinary tract calculi were obtained from 122 patients in the department of urinary surgery of the First Affiliated Hospital of Soochow University. All patients were scanned with a 64-detector row helical CT scanner using 6.50 mm collimation before ureterorenoscopy. Data from the preoperative spiral CT scans and postoperative chemical composition of urinary calculi were collected. The chemical composition analysis indicates that there were five types of pure calculi and three types of mixed calculi, including 39 calcium oxalate calculi, 12 calcium phosphate calculi, 10 calcium carbonate calculi, 8 magnesium ammonium phosphate calculi, 6 carbonated apatite, 21 uric acid/ammonium urate calculi, 10 uric acid/calcium oxalate calculi, and 16 calcium oxalate/calcium phosphate calculi. There were significant differences in the mean CT values among the five types of pure calculi (P < 0.001). Furthermore, we also observed significant differences in the mean CT values among three types of mixed calculi (P < 0.001). Significant differences in the mean CT values were also found among eight types of urinary calculi (P < 0.001). However, no statistically significant difference was observed between the mean CT values of magnesium ammonium phosphate calculi and uric acid/calcium oxalate calculi (P = 0.262). Our findings suggest that spiral CT could be a promising tool for determining the chemical composition of upper urinary tract calculi. © 2014 Wiley Periodicals, Inc.
Planning guidelines for computerized transaxial tomography (CT)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1976-11-23
Guidelines to assist local communities in review and decisionmaking related to computerized tomography (CT) 'head' and 'whole body' scanner needs and placement are presented. Although medical benefits for head scanning are well established, the proper role of whole body scanning in relation to other diagnostic procedures has not been determined. It is recommended that a 20 percent weighted consideration could be given to a potential CT scanner applicant's present capabilities in diagnostic 'body' work. The following guidelines for CT are recommended for use in assessing work qualifications of potential CT scanner applicants: (1) The facility must have an active neurosurgicalmore » service, with a geographically full-time board - certified neurosurgeon and at least 50 intracranial procedures performed annually. (2) The facility must have an active neurological service, with a geographically full-time board - certified neurologist. (3) The facility must have on staff a qualified neuroradiologist. It is recommended that the CT scanner utilization level be a minimum of 3,000 examinations per year per unit of new equipment. The applicant must submit financial data and must be committed to providing care to all patients, independent of ability to pay. The applicant must submit letters from area hospitals agreeing to utilize the scanner services. Additional criteria are given for body scanning work and for the number of scanners in a specific area. Detailed information is presented about scanner development and use in southeastern Pennsylvania and neighboring planning areas, and the cost of scanner operations is compared with revenues. The CT scanner committee membership is included.« less
el-Gamal, Osama; el-Badry, Amr
2009-07-01
We describe an objective method to evaluate kidney stone radiopacity for use in selection of cases suitable for ESWL. We recruited 76 adult patients with a solitary 1 to 2 cm renal pelvic stone. All patients underwent routine plain x-ray of the urinary tract but an aluminum step wedge (Gammex) was adapted to the cassette before x-ray exposure. This x-ray was then digitized and analyzed by histogram to calculate the gray level of the stone and of each step of the aluminum step wedge. This allowed radiographic stone density to be expressed in mm aluminum equivalent. All patients also underwent abdominopelvic computerized tomography and then ESWL was started. Stone density on plain x-ray was 1.83 to 5.93 mm aluminum equivalent. There was a positive correlation between these values and stone attenuation values on computerized tomography (r(2) 0.83, p <0.005). The 12 patients in whom ESWL failed were found to have stones of significantly higher density than stones in patients with complete stone fragmentation (mean +/- SD 4.8 +/- 0.74 vs 3.35 +/- 0.88 mm aluminum equivalent, p <0.005). There was also a positive correlation between stone radiopacity in mm aluminum equivalent and the total number of shock waves required to achieve complete fragmentation (r(2) 0.66, p <0.005). The aluminum step wedge with plain x-ray of the urinary tract provides a good reference for objectively assessing the radiopacity of renal calculi.
A Computerized Tomography Study of Vocal Tract Setting in Hyperfunctional Dysphonia and in Belting.
Saldias, Marcelo; Guzman, Marco; Miranda, Gonzalo; Laukkanen, Anne-Maria
2018-04-03
Vocal tract setting in hyperfunctional patients is characterized by a high larynx and narrowing of the epilaryngeal and pharyngeal region. Similar observations have been made for various singing styles, eg, belting. The voice quality in belting has been described to be loud, speech like, and high pitched. It is also often described as sounding "pressed" or "tense". The above mentioned has led to the hypothesis that belting may be strenuous to the vocal folds. However, singers and teachers of belting do not regard belting as particularly strenuous. This study investigates possible similarities and differences between hyperfunctional voice production and belting. This study concerns vocal tract setting. Four male patients with hyperfunctional dysphonia and one male contemporary commercial music singer were registered with computerized tomography while phonating on [a:] in their habitual speaking pitch. Additionally, the singer used the pitch G4 in belting. The scannings were studied in sagittal and transversal dimensions by measuring lengths, widths, and areas. Various similarities were found between belting and hyperfunction: high vertical larynx position, small hypopharyngeal width, and epilaryngeal outlet. On the other hand, belting differed from dysphonia (in addition to higher pitch) by a wider lip and jaw opening, and larger volumes of the oral cavity. Belting takes advantage of "megaphone shape" of the vocal tract. Future studies should focus on modeling and simulation to address sound energy transfer. Also, they should consider aerodynamic variables and vocal fold vibration to evaluate the "price of decibels" in these phonation types. Copyright © 2018. Published by Elsevier Inc.
Gaurav, Vivek; Srivastava, Nikhil; Rana, Vivek; Adlakha, Vivek Kumar
2013-01-01
Variations in morphology of root canals in primary teeth usually leads to complications during and after endodontic therapy. To improve the success in endodontics, a thorough knowledge of the root canal morphology is essential. The aim of this study was to assess the variation in number and morphology of the root canals of primary incisors and molars and to study the applicability of cone beam computerized tomography (CBCT) in assessing the same. A total of 60 primary molars and incisors with full root length were collected and various parameters such as the number of roots, number of canals, diameter of root canal at cementoenamel junction and middle-third, length and angulations of roots of primary molars and incisors were studied using CBCT. The observations were put to descriptive statistics to find out the frequency, mean, standard deviation and range for all four subgroups. Further, unpaired t-test was used to compare these parameters between subgroups and analysis of variance test was implemented to evaluate the parameters within the subgroups. The CBCT showed the presence of bifurcation of root canal at middle third in 13% of mandibular incisors while 20% of mandibular molars had two canals in distal root. The diameter of distobuccal root canal of maxillary molars and mesiolingual canal of mandibular molars was found to be minimum. CBCT is a relatively new and effective technology, which provides an auxiliary imaging modality to supplement conventional radiography for assessing the variation in root canal morphology of primary teeth.
Computerized tomography of the otic capsule and otoliths in the oyster toadfish, Opsanus tau.
Edds-Walton, Peggy L; Arruda, Julie; Fay, Richard R; Ketten, Darlene R
2015-02-01
The neurocranium of the toadfish (Opsanus tau) exhibits a distinct translucent region in the otic capsule (OC) that may have functional significance for the auditory pathway. This study used ultrahigh resolution computerized tomography (100 µm voxels) to compare the relative density of three sites along the OC (dorsolateral, midlateral, and ventromedial) and two reference sites (dorsal: supraoccipital crest; ventral: parasphenoid bone) in the neurocranium. Higher attenuation occurs where structural density is greater; thus, we compared the X-ray attenuations measured, which provided a measure of relative density. The maximum attenuation value was recorded for each of the five sites (x and y) on consecutive sections throughout the OC and for each of the three calcareous otoliths associated with the sensory maculae (lagena, saccule, and utricle) in the OC. All three otoliths had higher attenuations than any sites in the neurocranium. Both dorsal and ventral reference sites (supraoccipital crest and parasphenoid bone, respectively) had attenuation levels consistent with calcified bone and had relatively small, irregular variations along the length of the OC in all individuals. The lowest relative attenuations (lowest densities) occurred consistently at the three sites along the OC. In addition, the lowest attenuations measured along the OC occurred at the ventromedial site around the saccular otolith for all seven fish. The decrease in bone density along the OC is consistent with the hypothesis that there is a low-density channel in the skull to facilitate transmission of acoustic stimuli to the auditory endorgans of the ear. © 2014 Wiley Periodicals, Inc.
Chang, Pei-Yeh; Zeng, Qi; Wong, Kin-Sun; Wang, Chao-Jan; Chang, Chee-Jen
2016-01-01
This study radiographically examined the changes in the chest walls of patients with pectus excavatum (PE) after Nuss bar removal, to define the deformation caused by the bar and stabilizer. In the first part of the study, we compared the changes in chest radiographs of patients with PE to a preoperation PE control group. In the second part, we used multislice computed tomography (CT) scans to provide three-dimensional reconstructions with which to evaluate the changes to the thoracic wall. Part 1 From June 2006 to August 2011, 1,125 patients with PE who had posteroanterior chest radiographs taken before undergoing the Nuss procedure at four hospitals were enrolled as a preoperative control group. At the same time, 203 patients who had the bar removed were enrolled as the study group. The maximum dimensions of the outer boundary of the first to ninth rib pairs (R1-R9, rib pair width), chest height, and chest width were measured. Part 2 Thirty-one consecutive patients with PE (20 males and 11 females) who underwent Nuss bar removal were evaluated 7 to 30 days after operation. During this period, a further 34 patients with PE who had undergone CT imaging before bar insertion were evaluated and compared with the postoperative group. Part 1 The width of the lower ribs (R4-R9) after bar removal was significantly less than in the age-matched controls. The ribs adjacent to the bar (R5-R7) showed the greatest restriction. The width of the upper ribs (R1-R3) 2 to 3 years after bar placement did not differ significantly from the controls. Patients who were operated on after 10 years of age had less of a restrictive effect. Three years of bar placement resulted in more restriction than a 2-year period, particularly in patients younger than 10 years old. Part 2: A significant constriction of the chest wall was observed in 13 patients after removal of the Nuss bar. Constriction at ribs 5 to 8 was found to be present adjacent to the site of bar insertion. However, constriction of the chest wall was found in only 3 of the 34 patients in the preoperative group. The severity of constriction (as graded by the spline model) also increased in the postoperative group. The growth of the chest wall was restricted after placement of the Nuss bar for PE correction. Long-term follow-up of chest wall growth is needed to clarify whether such constriction resolves with time. Georg Thieme Verlag KG Stuttgart · New York.
Ruan, Chun; Yukihara, Eduardo G; Clouse, William J; Gasparian, Patricia B R; Ahmad, Salahuddin
2010-07-01
The extensive use of multislice computed tomography (MSCT) and the associated increase in patient dose calls for an accurate dose evaluation technique. Optically stimulated luminescence (OSL) dosimetry provides a potential solution to the arising concerns over patient dose. This study was intended to evaluate the feasibility and accuracy of OSL dosimeter systems in the diagnostic CT x-ray beam energy range. MSCT dose profiles were measured by irradiating OSL strips placed inside the extended PMMA head and body phantoms at different scan conditions by varying kVp settings (100, 120, and 140 kVp) and collimated beam widths (5, 10, 20, and 40 mm). All scans in this study were performed using a GE Lightspeed VCT scanner in axial mode. The exposed strips were then read out using a custom-made OSL strip reader and corrected with field-specific conversion factors. Based on the corrected OSL dose profile, the CTDI(450-OSL) and CTDI(l00-OSL) were evaluated. CTDI(100-IC) was also obtained using a 100 mm long pencil ionization chamber for accuracy verification. CTDI(100-efficiency) can be further evaluated by calculating the ratio of CTDI(100-OSL) and CTDI(450-OSL), which was compared to results from previous studies as well. The OSL detectors were found to have good sensitivity and dose response over a wide range of diagnostic CT x-ray beam energy viz. the primary beam and the scatter tail section of the dose profile. The differences between CTDI100 values obtained using the OSL strips and those obtained with 100 mm long pencil ionization chamber were < +/- 5% for all scan conditions, indicating good accuracy of the OSL system. It was also found that the CTDI(100-efficiency) did not significantly change as the beam width increased and tube voltage changed. The average CTDI(100-efficiency) at the center of the head and body phantoms were 72.6% and 56.2%, respectively. The corresponding values for the periphery of the head and body phantoms were 85.0% and 81.7%. These results agreed very well with previous results from the literature using other detection techniques or Monte Carlo simulations. The LED-based OSL system can be an accurate alternative device for CT dose evaluations. CTDI100 measurement with the use of a 100 mm pencil ionization chamber substantially underestimates the CTDIinfinity value even with 5 mm collimated beam width. The established complete set of CTDI(100-efficiency) correction factors for various scan parameters allows for accurately estimating CTDIinfinity with the current use of pencil chamber and dose phantoms. Combined with the simple calibration, it gives this work great potential to be used not only in routine clinical quality assurance checks but also as a promising tool for patient organ dose assessment.
NASA Astrophysics Data System (ADS)
Vogelgesang, Jonas; Schorr, Christian
2016-12-01
We present a semi-discrete Landweber-Kaczmarz method for solving linear ill-posed problems and its application to Cone Beam tomography and laminography. Using a basis function-type discretization in the image domain, we derive a semi-discrete model of the underlying scanning system. Based on this model, the proposed method provides an approximate solution of the reconstruction problem, i.e. reconstructing the density function of a given object from its projections, in suitable subspaces equipped with basis function-dependent weights. This approach intuitively allows the incorporation of additional information about the inspected object leading to a more accurate model of the X-rays through the object. Also, physical conditions of the scanning geometry, like flat detectors in computerized tomography as used in non-destructive testing applications as well as non-regular scanning curves e.g. appearing in computed laminography (CL) applications, are directly taken into account during the modeling process. Finally, numerical experiments of a typical CL application in three dimensions are provided to verify the proposed method. The introduction of geometric prior information leads to a significantly increased image quality and superior reconstructions compared to standard iterative methods.
Francis, I C; Kappagoda, M B; Cole, I E; Bank, L; Dunn, G D
1999-05-01
To evaluate the role of computed tomography in patients with dacryostenosis. One hundred seven cases of dacryostenosis (94 patients) were assessed by thorough clinical and lacrimal history and examination, and lacrimal region computerized tomography (CT). The lacrimal drainage system examination included the state and position of the puncta; Jones testing; lacrimal syringing; and, in the latter half of the study, telescopic nasal endoscopy. The patients were drawn from the hospital outpatients and private office of the operating lacrimal surgeon in this series (I.C.F.). Of the 107 cases, 79 either underwent dacryocystorhinostomy surgery or had this planned. In 14 of the 107 cases (12 patients), preoperative CT led to an alteration of patient management, usually referral to an otolaryngologist for further evaluation or treatment. In addition to the detection of two tumors extrinsic to the sac, conditions such as ethmoiditis, lacrimal sac mucoceles, soft tissue opacity in the nasolacrimal duct, gross nasal polyposis, fungal sinusitis, and a dacryolith were observed by CT. Similar to the role of functional endoscopic sinus surgery in otolaryngology, CT imaging will become increasingly important in the assessment of many patients with symptoms of lacrimal drainage obstruction.
Great Ears: Low-Frequency Sensitivity Correlates in Land and Marine Leviathans.
Ketten, D R; Arruda, J; Cramer, S; Yamato, M
2016-01-01
Like elephants, baleen whales produce low-frequency (LF) and even infrasonic (IF) signals, suggesting they may be particularly susceptible to underwater anthropogenic sound impacts. Analyses of computerized tomography scans and histologies of the ears in five baleen whale and two elephant species revealed that LF thresholds correlate with basilar membrane thickness/width and cochlear radii ratios. These factors are consistent with high-mass, low-stiffness membranes and broad spiral curvatures, suggesting that Mysticeti and Proboscidea evolved common inner ear adaptations over similar time scales for processing IF/LF sounds despite operating in different media.
Procedural-support music therapy in the healthcare setting: a cost-effectiveness analysis.
DeLoach Walworth, Darcy
2005-08-01
This comparative analysis examined the cost-effectiveness of music therapy as a procedural support in the pediatric healthcare setting. Many healthcare organizations are actively attempting to reduce the amount of sedation for pediatric patients undergoing various procedures. Patients receiving music therapy-assisted computerized tomography scans ( n = 57), echocardiograms ( n = 92), and other procedures ( n = 17) were included in the analysis. Results of music therapy-assisted procedures indicate successful elimination of patient sedation, reduction in procedural times, and decrease in the number of staff members present for procedures. Implications for nurses and music therapists in the healthcare setting are discussed.
A look at 15 years of planar thallium-201 imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaul, S.
1989-09-01
Extensive experience has been accumulated over the past 15 years regarding planar thallium-201 imaging. Quantitation of technically superior images provides a high sensitivity and specificity for the detection of CAD. In addition, planar thallium-201 images provide very important prognostic information in different clinical situations. Although single photon emission computerized tomography offers potential theoretical advantages over planar imaging, because of the problems involved in reconstruction, specifically the creation of artifacts, it may not be the ideal imaging modality in all situations. Good quality planar thallium-201 imaging still has an important role in clinical cardiology today. 144 references.
Liesegang Rings in Xanthogranulomatous Pyelonephritis: A Case Report
Pegas, Karla Laís; Edelweiss, Maria Isabel; Cambruzzi, Eduardo; Zettler, Cláudio Galleano
2010-01-01
Liesegang rings are concentric noncellular lamellar structures, rarely seen in vivo, occurring as a consequence of the accumulation of insoluble products in a colloidal matrix. These characteristic structures are a rare phenomenon usually found in association with cystic or inflammatory lesions and may be mistaken for parasites. The authors examined Liesegang rings from an inflammatory kidney lesion identified previously as a tumoral lesion on computerized tomography. On microscopic evaluation, Liesegang rings can be mistaken for eggs and larvae of parasites, psammoma bodies and calcification. Special stains like PAS, Grocott, von Kossa and Masson's trichrome facilitate the diagnosis. PMID:21151725
CMT for biomedical and other applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spanne, P.
This session includes two presentations describing applications for x-ray tomography using synchrotron radiation for biomedical uses and fluid flow modeling, and outlines advantages for using monoenergetic x-rays. Contrast mechanisms are briefly described and several graphs of absorbed doses and scattering of x-rays are included. Also presented are schematic diagrams of computerized tomographic instrumentation with camera head. A brief description of goals for a real time tomographic system and expected improvements to the system are described. Color photomicrographs of the Berea Sandstone and human bone are provided, as well as a 3-D microtomographic reconstruction of a human vertebra sample.
Splenic infarction at low altitude in a child with hemoglobin S-C disease.
Alvarado, C S; Wyly, B; Buchanan, I; Fajman, W A
1988-08-01
We describe a 15-year-old black boy with hemoglobin S-C disease living in Atlanta (altitude 1,034 ft), with no prior history of aircraft or mountain travel, who developed splenic infarction. The clinical picture was characterized by severe left upper quadrant abdominal pain, fever, splenomegaly, and hematologic and scintigraphic evidence of functional asplenia. The diagnosis was suggested by liver/spleen scintigraphy and further confirmed by ultrasonography and computerized tomography (CT) of the spleen. Treatment consisted of analgesics, intravenous fluids, and short-term antibiotic therapy. The child recovered without sequelae.
High resolution collimator system for X-ray detector
Eberhard, Jeffrey W.; Cain, Dallas E.
1987-01-01
High resolution in an X-ray computerized tomography (CT) inspection system is achieved by using a collimator/detector combination to limit the beam width of the X-ray beam incident on a detector element to the desired resolution width. In a detector such as a high pressure Xenon detector array, a narrow tapered collimator is provided above a wide detector element. The collimator slits have any desired width, as small as a few mils at the top, the slit width is easily controlled, and they are fabricated on standard machines. The slit length determines the slice thickness of the CT image.
A case of mycotic aneurysm due to Burkholderia pseudomallei.
Ding, C H; Hussin, S; Tzar, M N; Rahman, M M; Ramli, S R
2013-04-01
Burkholderia pseudomallei is an free-living gram-negative bacterium causing melioidosis and is endemic in Southeast Asia. A 56-year-old diabetic construction worker with a 1-month history of abdominal pain and 1-day history of high-grade fever was found to have a left non-dissecting infrarenal mycotic aortic aneurysm by abdominal computerized tomography scan. Bacteriological examination of his blood yielded Burkholderia pseudomallei. The patient was treated with right axillo-bifemoral bypass with excision of aneurysm and high-dose intravenous ceftazidime for two weeks, followed by oral trimethoprim/sulfamethoxazole and oral doxycycline for a minimum of five months.
Exertional headache as unusual presentation of the syndrome of an elongated styloid process.
Maggioni, Ferdinando; Marchese-Ragona, Rosario; Mampreso, Edoardo; Mainardi, Federico; Zanchin, Giorgio
2009-05-01
We present the case of a 34-year-old man with a 2-year history of pain related to efforts in heavy lifting, beginning in the right ear and radiating to the neck and to the vertex. He underwent multiple negative neuroimaging examinations, until a 3-dimensional computerized tomography scan of the pharyngeal region evidenced an elongated styloid process. A diagnosis of Eagle's syndrome was made. The excision of the elongated styloid process was performed, resulting in complete and lasting pain relief. We focus on Eagle's syndrome and in particular on this atypical presentation.
Secondary signet-ring cell adenocarcinoma of urinary bladder from a gastric primary.
Sharma, Pramod K; Vijay, Mukesh K; Das, Ranjit K; Chatterjee, Uttara
2011-05-01
Primary bladder tumor is a frequent urological malignancy, whereas the incidence of secondary bladder tumor from a distant organ is quite rare. Secondary bladder neoplasms represent 1% of all malignant bladder tumors, of which distant metastases from stomach account for about 4% of cases. We present the case of a 30-year-old male who underwent partial gastrectomy for Signet-ring cell carcinoma of the stomach and presented 2 years later with hematuria. On computerized tomography scan, a bladder tumor was found which was resected cystoscopically. The histopathological examination revealed secondary Signet-ring cell adenocarcinoma of the urinary bladder.
Radiographic evidence of disuse osteoporosis in the monkey /M. nemestrina/
NASA Technical Reports Server (NTRS)
Young, D. R.; Schneider, V. S.
1981-01-01
Radiological techniques were utilized for monitoring progressive changes in compact bone in the tibia of monkeys during experimentally induced osteopenia. Bone mass loss in the tibia during restraint was evaluated from radiographs, from bone mineral analysis, and from images reconstructed from gamma ray computerized tomography. The losses during 6 months of restraint tended to occur predominantly in the proximal tibia and were characterized by subperiosteal bone loss, intracortical striations, and scalloped endosteal surfaces. Bone mineral content in the cross section of the tibia declined 17-21%. In 6 months of recovery, the mineral content of the proximal tibia remained depressed.
Magnetic resonance imaging for the ophthalmologist: A primer
Simha, Arathi; Irodi, Aparna; David, Sarada
2012-01-01
Magnetic resonance imaging (MRI) and computerized tomography (CT) have added a new dimension in the diagnosis and management of ocular and orbital diseases. Although CT is more widely used, MRI is the modality of choice in select conditions and can be complimentary to CT in certain situations. The diagnostic yield is best when the ophthalmologist and radiologist work together. Ophthalmologists should be able to interpret these complex imaging modalities as better clinical correlation is then possible. In this article, we attempt to describe the basic principles of MRI and its interpretation, avoiding confusing technical terms. PMID:22824600
Superior mesenteric vein thrombosis complicating appendicular masses.
Echtibi, Salma S; Bashir, Masoud O; Ahmed, Misbah U; Branicki, Frank J; Abu-Zidan, Fikri M
2003-09-01
Mesenteric vein thrombosis (MVT) is rare. Its diagnosis is usually difficult and delayed. Herein, we report 2 patients who developed MVT as a complication of an appendicular mass. One of them had appendectomy and developed fever 10 days postoperatively. The other was treated conservatively. An abdominal computerized tomography (CT) scan with intravenous contrast was helpful in diagnosing the superior MVT in both patients, which were not suspected. Intravenous contrast should be used when performing CT of an appendicular mass. Special interest should be directed at studying the superior mesenteric vein. Early diagnosis of our patients helped to start early medical treatment with anticoagulation.
Rolinski, Michal; Griffanti, Ludovica; Piccini, Paola; Roussakis, Andreas A; Szewczyk-Krolikowski, Konrad; Menke, Ricarda A; Quinnell, Timothy; Zaiwalla, Zenobia; Klein, Johannes C; Mackay, Clare E; Hu, Michele T M
2016-08-01
SEE POSTUMA DOI101093/AWW131 FOR A SCIENTIFIC COMMENTARY ON THIS ARTICLE: Resting state functional magnetic resonance imaging dysfunction within the basal ganglia network is a feature of early Parkinson's disease and may be a diagnostic biomarker of basal ganglia dysfunction. Currently, it is unclear whether these changes are present in so-called idiopathic rapid eye movement sleep behaviour disorder, a condition associated with a high rate of future conversion to Parkinson's disease. In this study, we explore the utility of resting state functional magnetic resonance imaging to detect basal ganglia network dysfunction in rapid eye movement sleep behaviour disorder. We compare these data to a set of healthy control subjects, and to a set of patients with established early Parkinson's disease. Furthermore, we explore the relationship between resting state functional magnetic resonance imaging basal ganglia network dysfunction and loss of dopaminergic neurons assessed with dopamine transporter single photon emission computerized tomography, and perform morphometric analyses to assess grey matter loss. Twenty-six patients with polysomnographically-established rapid eye movement sleep behaviour disorder, 48 patients with Parkinson's disease and 23 healthy control subjects were included in this study. Resting state networks were isolated from task-free functional magnetic resonance imaging data using dual regression with a template derived from a separate cohort of 80 elderly healthy control participants. Resting state functional magnetic resonance imaging parameter estimates were extracted from the study subjects in the basal ganglia network. In addition, eight patients with rapid eye movement sleep behaviour disorder, 10 with Parkinson's disease and 10 control subjects received (123)I-ioflupane single photon emission computerized tomography. We tested for reduction of basal ganglia network connectivity, and for loss of tracer uptake in rapid eye movement sleep behaviour disorder and Parkinson's disease relative to each other and to controls. Connectivity measures of basal ganglia network dysfunction differentiated both rapid eye movement sleep behaviour disorder and Parkinson's disease from controls with high sensitivity (96%) and specificity (74% for rapid eye movement sleep behaviour disorder, 78% for Parkinson's disease), indicating its potential as an indicator of early basal ganglia dysfunction. Rapid eye movement sleep behaviour disorder was indistinguishable from Parkinson's disease on resting state functional magnetic resonance imaging despite obvious differences on dopamine transported single photon emission computerized tomography. Basal ganglia connectivity is a promising biomarker for the detection of early basal ganglia network dysfunction, and may help to identify patients at risk of developing Parkinson's disease in the future. Future risk stratification using a polymodal approach could combine basal ganglia network connectivity with clinical and other imaging measures, with important implications for future neuroprotective trials in rapid eye movement sleep behaviour disorder. © The Author (2016). Published by Oxford University Press on behalf of the Guarantors of Brain.
Rolinski, Michal; Griffanti, Ludovica; Piccini, Paola; Roussakis, Andreas A.; Szewczyk-Krolikowski, Konrad; Menke, Ricarda A.; Quinnell, Timothy; Zaiwalla, Zenobia; Klein, Johannes C.; Mackay, Clare E.
2016-01-01
Abstract See Postuma (doi:10.1093/aww131) for a scientific commentary on this article. Resting state functional magnetic resonance imaging dysfunction within the basal ganglia network is a feature of early Parkinson’s disease and may be a diagnostic biomarker of basal ganglia dysfunction. Currently, it is unclear whether these changes are present in so-called idiopathic rapid eye movement sleep behaviour disorder, a condition associated with a high rate of future conversion to Parkinson’s disease. In this study, we explore the utility of resting state functional magnetic resonance imaging to detect basal ganglia network dysfunction in rapid eye movement sleep behaviour disorder. We compare these data to a set of healthy control subjects, and to a set of patients with established early Parkinson’s disease. Furthermore, we explore the relationship between resting state functional magnetic resonance imaging basal ganglia network dysfunction and loss of dopaminergic neurons assessed with dopamine transporter single photon emission computerized tomography, and perform morphometric analyses to assess grey matter loss. Twenty-six patients with polysomnographically-established rapid eye movement sleep behaviour disorder, 48 patients with Parkinson’s disease and 23 healthy control subjects were included in this study. Resting state networks were isolated from task-free functional magnetic resonance imaging data using dual regression with a template derived from a separate cohort of 80 elderly healthy control participants. Resting state functional magnetic resonance imaging parameter estimates were extracted from the study subjects in the basal ganglia network. In addition, eight patients with rapid eye movement sleep behaviour disorder, 10 with Parkinson’s disease and 10 control subjects received 123I-ioflupane single photon emission computerized tomography. We tested for reduction of basal ganglia network connectivity, and for loss of tracer uptake in rapid eye movement sleep behaviour disorder and Parkinson’s disease relative to each other and to controls. Connectivity measures of basal ganglia network dysfunction differentiated both rapid eye movement sleep behaviour disorder and Parkinson’s disease from controls with high sensitivity (96%) and specificity (74% for rapid eye movement sleep behaviour disorder, 78% for Parkinson’s disease), indicating its potential as an indicator of early basal ganglia dysfunction. Rapid eye movement sleep behaviour disorder was indistinguishable from Parkinson’s disease on resting state functional magnetic resonance imaging despite obvious differences on dopamine transported single photon emission computerized tomography. Basal ganglia connectivity is a promising biomarker for the detection of early basal ganglia network dysfunction, and may help to identify patients at risk of developing Parkinson’s disease in the future. Future risk stratification using a polymodal approach could combine basal ganglia network connectivity with clinical and other imaging measures, with important implications for future neuroprotective trials in rapid eye movement sleep behaviour disorder. PMID:27297241
Ramanathan, Suhashini; Solete, Pradeep
2015-11-01
To evaluate the remaining dentin thickness of teeth after cleaning and shaping the root canal using three rotary instrumentation technique using cone-beam computed tomography (CBCT). This in vitro study is being done with 30 premolar samples with 20' curvature. The study is divided into three groups a CBCT was taken to measure the shortest distance from the root canal outline to the closest adjacent root surface was measured at each level from the cementoenamel junction (CEJ) (1,3, 5 and 7 mm) before and after root canal instrumentation. The purpose of this study was to compare the effects of different instruments used to prepare curved root canals on the remaining cervical dentin thickness and total amount of dentin removed from root canals during instrumentation by using multi-slice CBCT. The remaining dentin thickness is very much necessary for the success rate of root canal treatment. However, this study helps to prove that a conservative preparation with a sound remaining dentin thickness is much more advisable. It was observed that there was a significant difference at 1 and 3 mm (p < 0.05) and at 5 and 7 mm there was no significant difference ( p > 0.05). Mtwo has removed less amount dentin when compared to ProTaper Universal and ProTaper Next system at 1 and 3 mm. Under the conditions of the study, we concluded that ProTaper Universal and ProTaper Next should be used judiciously, as it causes higher thinning of root dentin of the root when compared with Mtwo.
Emerging Imaging Tools for Use with Traumatic Brain Injury Research
Wilde, Elisabeth A.; Tong, Karen A.; Holshouser, Barbara A.
2012-01-01
Abstract This article identifies emerging neuroimaging measures considered by the inter-agency Pediatric Traumatic Brain Injury (TBI) Neuroimaging Workgroup. This article attempts to address some of the potential uses of more advanced forms of imaging in TBI as well as highlight some of the current considerations and unresolved challenges of using them. We summarize emerging elements likely to gain more widespread use in the coming years, because of 1) their utility in diagnosis, prognosis, and understanding the natural course of degeneration or recovery following TBI, and potential for evaluating treatment strategies; 2) the ability of many centers to acquire these data with scanners and equipment that are readily available in existing clinical and research settings; and 3) advances in software that provide more automated, readily available, and cost-effective analysis methods for large scale data image analysis. These include multi-slice CT, volumetric MRI analysis, susceptibility-weighted imaging (SWI), diffusion tensor imaging (DTI), magnetization transfer imaging (MTI), arterial spin tag labeling (ASL), functional MRI (fMRI), including resting state and connectivity MRI, MR spectroscopy (MRS), and hyperpolarization scanning. However, we also include brief introductions to other specialized forms of advanced imaging that currently do require specialized equipment, for example, single photon emission computed tomography (SPECT), positron emission tomography (PET), encephalography (EEG), and magnetoencephalography (MEG)/magnetic source imaging (MSI). Finally, we identify some of the challenges that users of the emerging imaging CDEs may wish to consider, including quality control, performing multi-site and longitudinal imaging studies, and MR scanning in infants and children. PMID:21787167
Xue, Hua-dan; Liu, Wei; Sun, Hao; Wang, Xuan; Chen, Yu; Su, Bai-yan; Sun, Zhao-yong; Chen, Fang; Jin, Zheng-yu
2010-12-01
To analyze the clinical value of multiple sequences derived from dual-source computed tomography (DSCT) dual-energy scan mode in detecting pancreatic adenocarcinoma. Totally 23 patients with clinically or pathologically diagnosed pancreatic cancer were enrolled in this retrospective study. DSCT (Definition Flash) was used and dual-energy scan mode was used in their pancreatic parenchyma phase scan (100kVp/230mAs and Sn140kVp/178mAs) . Mono-energetic 60kev, mono-energetic 80kev, mono-energetic 100kev, mono-energetic 120kev, linear blend image, non-linear blend image, and iodine map were acquired. pancreatic parenchyma-tumor CT value difference, ratio of tumor to pancreatic parenchyma, and pancreatic parenchyma-tumor contrast to noise ratio were calculated. One-way ANOVA was used for the comparison of diagnostic values of the above eight different dual-energy derived sequences for pancreatic cancer. The pancreatic parenchyma-tumor CT value difference, ratio of tumor to pancreatic parenchyma, and pancreatic parenchyma-tumor contrast to noise ratio were significantly different among eight sequences (P<0.05) . Mono-energetic 60kev image showed the largest parenchyma-tumor CT value [ (77.53 ± 23.42) HU] , and iodine map showed the lowest tumor/parenchyma enhancement ratio (0.39?0.12) and the largest contrast to noise ratio (4.08 ± 1.46) . Multiple sequences can be derived from dual-energy scan mode with DSCT via multiple post-processing methods. Integration of these sequences may further improve the sensitivity of the multislice spiral CT in the diagnosis of pancreatic cancer.
Automated detection of pulmonary nodules in CT images with support vector machines
NASA Astrophysics Data System (ADS)
Liu, Lu; Liu, Wanyu; Sun, Xiaoming
2008-10-01
Many methods have been proposed to avoid radiologists fail to diagnose small pulmonary nodules. Recently, support vector machines (SVMs) had received an increasing attention for pattern recognition. In this paper, we present a computerized system aimed at pulmonary nodules detection; it identifies the lung field, extracts a set of candidate regions with a high sensitivity ratio and then classifies candidates by the use of SVMs. The Computer Aided Diagnosis (CAD) system presented in this paper supports the diagnosis of pulmonary nodules from Computed Tomography (CT) images as inflammation, tuberculoma, granuloma..sclerosing hemangioma, and malignant tumor. Five texture feature sets were extracted for each lesion, while a genetic algorithm based feature selection method was applied to identify the most robust features. The selected feature set was fed into an ensemble of SVMs classifiers. The achieved classification performance was 100%, 92.75% and 90.23% in the training, validation and testing set, respectively. It is concluded that computerized analysis of medical images in combination with artificial intelligence can be used in clinical practice and may contribute to more efficient diagnosis.
Multislice imaging of integrated circuits by precession X-ray ptychography.
Shimomura, Kei; Hirose, Makoto; Takahashi, Yukio
2018-01-01
A method for nondestructively visualizing multisection nanostructures of integrated circuits by X-ray ptychography with a multislice approach is proposed. In this study, tilt-series ptychographic diffraction data sets of a two-layered circuit with a ∼1.4 µm gap at nine incident angles are collected in a wide Q range and then artifact-reduced phase images of each layer are successfully reconstructed at ∼10 nm resolution. The present method has great potential for the three-dimensional observation of flat specimens with thickness on the order of 100 µm, such as three-dimensional stacked integrated circuits based on through-silicon vias, without laborious sample preparation.
2012-01-01
Background Computed tomography (CT) scanning has become essential in the early diagnostic phase of trauma care because of its high diagnostic accuracy. The introduction of multi-slice CT scanners and infrastructural improvements made total-body CT scanning technically feasible and its usage is currently becoming common practice in several trauma centers. However, literature provides limited evidence whether immediate total-body CT leads to better clinical outcome then conventional radiographic imaging supplemented with selective CT scanning in trauma patients. The aim of the REACT-2 trial is to determine the value of immediate total-body CT scanning in trauma patients. Methods/design The REACT-2 trial is an international, multicenter randomized clinical trial. All participating trauma centers have a multi-slice CT scanner located in the trauma room or at the Emergency Department (ED). All adult, non-pregnant, severely injured trauma patients according to predefined criteria will be included. Patients in whom direct scanning will hamper necessary cardiopulmonary resuscitation or who require an immediate operation because of imminent death (both as judged by the trauma team leader) are excluded. Randomization will be computer assisted. The intervention group will receive a contrast-enhanced total-body CT scan (head to pelvis) during the primary survey. The control group will be evaluated according to local conventional trauma imaging protocols (based on ATLS guidelines) supplemented with selective CT scanning. Primary outcome will be in-hospital mortality. Secondary outcomes are differences in mortality and morbidity during the first year post trauma, several trauma work-up time intervals, radiation exposure, general health and quality of life at 6 and 12 months post trauma and cost-effectiveness. Discussion The REACT-2 trial is a multicenter randomized clinical trial that will provide evidence on the value of immediate total-body CT scanning during the primary survey of severely injured trauma patients. If immediate total-body CT scanning is found to be the best imaging strategy in severely injured trauma patients it could replace conventional imaging supplemented with CT in this specific group. Trial Registration ClinicalTrials.gov: (NCT01523626). PMID:22458247
He, Zhen; Wan, Yeda
2018-01-01
Fetal-type posterior cerebral artery (FTP) is a common anatomic variation that is closely associated with intracranial aneurysm. In the present study, multislice computed tomography angiography (CTA) was performed to assess whether FTP is a risk factor for intracranial aneurysm. CTA data of 364 consecutive cases of patients who were suspected with cerebrovascular disease or intracranial aneurysm of intracranial artery from 2013 to 2016 were reviewed and the incidence rates of FTP, other variations of the circle of Willis, intracranial aneurysm and FTP with intracranial aneurysm were evaluated. The χ 2 test was used to assess the influence of FTP and gender on the incidence rates of other variations of the circle of Willis, intracranial aneurysm and internal carotid artery-posterior communicating artery (ICA-PComA) aneurysm. Binary logistic regression analysis was performed to assess the associations of FTP and gender with intracranial aneurysm and ICA-PComA aneurysm. Compared with non-FTP patients, FTP cases exhibited significantly higher rates of other variations of the circle of Willis (χ 2 =80.173, P<0.001) and ICA-PComA aneurysm (χ 2 =4.437, P=0.035). Among patients with FTP and bilateral FTP, more female than male patients with intracranial aneurysm were identified. However, among all patients with intracranial aneurysm, no statistically significant differences in the prevalence of FTP (χ 2 =2.577, P=0.108) and bilateral FTP (χ 2 =2.199, P=0.159) between males and females were identified. Binary logistic regression analysis revealed that FTP and gender were risk factors for intracranial aneurysm and ICA-PComA aneurysm. A moderate association between FTP and ICA-PComA aneurysm (OR=2.762) were identified, although there was a weak association between FTP and intracranial aneurysm [odds ratio (OR)=1.365]. Furthermore, a strong association was identified between gender and intracranial aneurysm (OR=0.328), and a moderate association existed between gender and ICA-PComA aneurysm (OR=0.357). In conclusion, female gender is an independent risk factor for intracranial aneurysm, and FTP and female gender are independent risk factors for ICA-PComA aneurysm.
He, Zhen; Wan, Yeda
2018-01-01
Fetal-type posterior cerebral artery (FTP) is a common anatomic variation that is closely associated with intracranial aneurysm. In the present study, multislice computed tomography angiography (CTA) was performed to assess whether FTP is a risk factor for intracranial aneurysm. CTA data of 364 consecutive cases of patients who were suspected with cerebrovascular disease or intracranial aneurysm of intracranial artery from 2013 to 2016 were reviewed and the incidence rates of FTP, other variations of the circle of Willis, intracranial aneurysm and FTP with intracranial aneurysm were evaluated. The χ2 test was used to assess the influence of FTP and gender on the incidence rates of other variations of the circle of Willis, intracranial aneurysm and internal carotid artery-posterior communicating artery (ICA-PComA) aneurysm. Binary logistic regression analysis was performed to assess the associations of FTP and gender with intracranial aneurysm and ICA-PComA aneurysm. Compared with non-FTP patients, FTP cases exhibited significantly higher rates of other variations of the circle of Willis (χ2=80.173, P<0.001) and ICA-PComA aneurysm (χ2=4.437, P=0.035). Among patients with FTP and bilateral FTP, more female than male patients with intracranial aneurysm were identified. However, among all patients with intracranial aneurysm, no statistically significant differences in the prevalence of FTP (χ2=2.577, P=0.108) and bilateral FTP (χ2=2.199, P=0.159) between males and females were identified. Binary logistic regression analysis revealed that FTP and gender were risk factors for intracranial aneurysm and ICA-PComA aneurysm. A moderate association between FTP and ICA-PComA aneurysm (OR=2.762) were identified, although there was a weak association between FTP and intracranial aneurysm [odds ratio (OR)=1.365]. Furthermore, a strong association was identified between gender and intracranial aneurysm (OR=0.328), and a moderate association existed between gender and ICA-PComA aneurysm (OR=0.357). In conclusion, female gender is an independent risk factor for intracranial aneurysm, and FTP and female gender are independent risk factors for ICA-PComA aneurysm. PMID:29434687
Ando, Kei; Imagama, Shiro; Ito, Zenya; Kobayashi, Kazuyoshi; Ukai, Junichi; Muramoto, Akio; Shinjo, Ryuichi; Matsumoto, Tomohiro; Nakashima, Hiroaki; Ishiguro, Naoki
2014-05-01
Retrospective clinical study. To investigate, using multislice CT images, how thoracic ossification of the posterior longitudinal ligament (OPLL) changes with time after thoracic posterior fusion surgery. Few studies have evaluated thoracic OPLL preoperatively and post using computed tomography (CT). The subjects included 19 patients (7 men and 12 women) with an average age at surgery of 52 years (38-66 y) who underwent indirect posterior decompression with corrective fusion and instrumentation at our institute. Minimum follow-up period was 1 year, and averaged 3 years 10 months (12-120 mo). Using CT images, we investigated fusion range, preoperative and postoperative Cobb angles of thoracic fusion levels, intraoperative and postoperative blood loss, operative time, hyperintense areas on preoperative MRI of thoracic spine and thickness of the OPLL on the reconstructed sagittal, multislice CT images taken before the operation and at 3 months, 6 months and 1 year after surgery. The basic fusion area was 3 vertebrae above and below the OPLL lesion. The mean operative time was 7 hours and 48 min (4 h 39 min-10 h 28 min), and blood loss was 1631 mL (160-11,731 mL). Intramedullary signal intensity change on magnetic resonance images was observed at the most severe ossification area in 18 patients. Interestingly, the rostral and caudal ossification regions of the OPLLs, as seen on sagittal CT images, were discontinuous across the disk space in all patients. Postoperatively, the discontinuous segments connected in all patients without progression of OPLL thickness by 5.1 months on average. All patients needing surgery had discontinuity across the disk space between the rostral and caudal ossified lesions as seen on CT. This discontinuity was considered to be the main reason for the myelopathy because a high-intensity area on magnetic resonance imaging was seen in 18 of 19 patients at the same level. Rigid fixation with instrumentation may allow the discontinuous segments to connect in patients without a concomitant thickening of the OPLL.
Van Dessel, Jeroen; Nicolielo, Laura Ferreira Pinheiro; Huang, Yan; Coudyzer, Walter; Salmon, Benjamin; Lambrichts, Ivo; Jacobs, Reinhilde
The aim of this study was to assess whether cone beam computed tomography (CBCT) may be used for clinically reliable alveolar bone quality assessment in comparison to its clinical alternatives, multislice computed tomography and the gold standard (micro-CT). Six dentate mandibular bone samples were scanned with seven CBCT devices (ProMax 3D Max, NewTom GiANO, Cranex 3D, 3D Accuitomo 170, Carestream 9300, Scanora 3D, I-CAT Next generation), one micro-CT scanner (SkyScan 1174) and one MSCT machine (Somatom Definition Flash) using two protocols (standard and high-resolution). MSCT and CBCT images were automatically spatially aligned on the micro-CT scan of the corresponding sample. A volume of interest was manually delineated on the micro-CT image and overlaid on the other scanning devices. Alveolar bone structures were automatically extracted using the adaptive thresholding algorithm. Based on the resulting binary images, an automatic 3D morphometric quantification was performed in a CT-Analyser (Bruker, Kontich, Belgium). The reliability and measurement errors were calculated for each modality compared to the gold standard micro-CT. Both MSCT and CBCT were associated with a clinically and statistically (P <0.05) significant measurement error. Bone quantity-related morphometric indices (bone volume fraction 8.41% min to 17.90% max, bone surface density -0.47 mm-1 min to 0.16 mm-1 max and trabecular thickness 0.15 mm min to 0.31 mm max) were significantly (P <0.05) overestimated, resulting in significantly (P <0.05) closer trabecular pores (total porosity percentage -8.41% min to -17.90% max and fractal dimension 0.08 min to 0.17 max) in all scanners compared to micro-CT. However, the structural pattern of the alveolar bone remained similar compared to that of the micro-CT for the ProMax 3D Max, NewTom GiANO, Cranex 3D, 3D Accuitomo 170 and Carestream 9300. On the other hand, the Scanora 3D, i-CAT Next Generation, standard and high-resolution MSCT displayed an overrated bone quantity and aberrant structural pattern compared to other scanning devices. The calculation of morphometric indices had an overall high reliability (intraclass correlation coefficient [ICC] 0.62 min to 0.99 max), except for the i-CAT Next Generation CBCT (ICC 0.26 min to 0.86 max) and standard resolution MSCT (ICC 0.10 min to 0.62 max). This study demonstrated that most CBCT machines may be able to quantitatively assess alveolar bone quality, with a level of accuracy and reliability that approaches micro-CT. One may therefore propose to extrapolate this to clinical CBCT imaging, certainly when there is a need for implant rehabilitation in dentate jaw bones. Conflict-of-interest statement: There is no conflict of interest to declare. Fellowship support was received from Research Foundation Flanders (FWO) from the Belgian government and from the Coordination for the Improvement of Higher Education Personnel (CAPES) programme, Science without Borders, from the Brazilian government.
Peretti, Charles-Siegfried; Peretti, Charles Roger; Kozora, Elizabeth; Papathanassiou, Dimitri; Chouinard, Virginie-Anne; Chouinard, Guy
2012-01-01
Systemic lupus erythematosus (SLE) is known to induce psychiatric disorders, from psychoses to maladaptive coping. Brain autoantibodies were proposed to explain SLE neuropsychiatric disorders and found to be elevated before the onset of clinical symptoms. We assessed cognition in Caucasian SLE women with elevated autoantibodies without overt neuropsychiatric syndromes, in conjunction with single photon emission computerized tomography (SPECT). 31 women meeting SLE criteria of the American College of Rheumatology (ACR) were included. Patients who met the ACR neuropsychiatric definition were excluded. Matched controls were 23 healthy women from the Champagne-Ardenne region, France. Participants completed neuropsychological and autoantibodies measurements, and 19 completed SPECT. 61% (19/31) of women with SLE and 53% (9/17) of those with normal SPECT had significant global cognitive impairment defined as 4 T-scores <40 in cognitive tests, compared to 0% (0/23) of controls. SLE women also had significantly greater cognitive dysfunction (mean T-score) on the Wechsler Adult Intelligence Scale (WAIS) visual backspan, Trail Making Test A and B, WAIS Digit Symbol Substitution Test and Stroop Interference, compared to controls. Elevated antinuclear antibody correlated with impairment in the WAIS visual span, WAIS visual backspan, and cancellation task; elevated anti-double-stranded DNA antibody and anticardiolipin correlated respectively with impairment in the Trail Making Test A and WAIS auditive backspan. Two SLE women had abnormal SPECT. A high prevalence of cognitive deficits was found in Caucasian SLE women compared to normal women, which included impairment in cognitive domains important for daily activities. Elevated autoantibodies tended to correlate with cognitive dysfunction. Copyright © 2012 S. Karger AG, Basel.
Viers, Boyd R; Viers, Lyndsay D; Hull, Nathan C; Hanson, Theodore J; Mehta, Ramila A; Bergstralh, Eric J; Vrtiska, Terri J; Krambeck, Amy E
2015-11-01
To evaluate the association between clinicoradiographic features and need for prestenting (PS) because of inability of the ureter to accommodate the ureteroscope, or ureteral access sheath, at the time of stone treatment. From 2009 to 2013, 120 consecutive nonstented patients underwent ureteroscopic stone treatment with preoperative computerized tomography urogram. Acute stone events with obstruction or infection were excluded. Preoperative radiographic imaging underwent radiologist review. Clinicoradiographic features were characterized, and multivariable logistic regression models were used to identify covariates independently associated with need for PS. Of the 154 renal units treated, 25 (16%) required PS for failed primary access. PS ureters were less likely to have a history of prior ipsilateral ureteral stent (4% vs 31%) or surgery (8% vs 36%; P <.05). Radiographically, PS ureters had a narrower ureteropelvic junction (4 mm vs 5 mm) and were more likely to have <50% ureteral opacification on computerized tomography urogram (32% vs 9%; P <.05). On multivariable analysis, prior ipsilateral ureteral stent (odds ratio [OR] = 0.11) and stone surgery (OR = 0.15) reduced the need for PS; meanwhile, <50% ureteral opacification (OR = 4.41) was independently associated with an increased risk of access failure. We report a 16% incidence of access failure requiring PS at time of ureteroscopy. Clinically, there was an 89% and 85% risk reduction in the need for PS with prior history of ipsilateral ureteral stent or surgery. Radiographically, there was a 4.4-fold increased risk of PS with <50% ureteral opacification. Accordingly, our findings may assist in counseling and operative management of the difficult ureter. Copyright © 2015 Elsevier Inc. All rights reserved.
Mi, Jia; Li, Jie; Zhang, Qinglu; Wang, Xing; Liu, Hongyu; Cao, Yanlu; Liu, Xiaoyan; Sun, Xiao; Shang, Mengmeng; Liu, Qing
2016-01-01
Abstract The purpose of the study was to establish a mathematical model for correlating the combination of ultrasonography and noncontrast helical computerized tomography (NCHCT) with the total energy of Holmium laser lithotripsy. In this study, from March 2013 to February 2014, 180 patients with single urinary calculus were examined using ultrasonography and NCHCT before Holmium laser lithotripsy. The calculus location and size, acoustic shadowing (AS) level, twinkling artifact intensity (TAI), and CT value were all documented. The total energy of lithotripsy (TEL) and the calculus composition were also recorded postoperatively. Data were analyzed using Spearman's rank correlation coefficient, with the SPSS 17.0 software package. Multiple linear regression was also used for further statistical analysis. A significant difference in the TEL was observed between renal calculi and ureteral calculi (r = –0.565, P < 0.001), and there was a strong correlation between the calculus size and the TEL (r = 0.675, P < 0.001). The difference in the TEL between the calculi with and without AS was highly significant (r = 0.325, P < 0.001). The CT value of the calculi was significantly correlated with the TEL (r = 0.386, P < 0.001). A correlation between the TAI and TEL was also observed (r = 0.391, P < 0.001). Multiple linear regression analysis revealed that the location, size, and TAI of the calculi were related to the TEL, and the location and size were statistically significant predictors (adjusted r2 = 0.498, P < 0.001). A mathematical model correlating the combination of ultrasonography and NCHCT with TEL was established; this model may provide a foundation to guide the use of energy in Holmium laser lithotripsy. The TEL can be estimated by the location, size, and TAI of the calculus. PMID:27930563
Bathla, Meeta; Doshi, Hiren; Kansara, Atul
2018-03-01
Role of high resolution computerized tomography (HRCT) of temporal bone is established in cases of atticoantral chronic suppurative otitis media (CSOM) with intracranial complications. Routine use of HRCT in management of patients of atticoantral CSOM without intracranial complications has been an issue of debate. The aim of this study was to evaluate the routine use of HRCT of temporal bone in such cases. This study was a prospective study done at LG hospital, AMC MET Medical College, Ahmedabad to evaluate and compare the temporal bone findings in HRCT and intraoperative findings in 100 patients with atticoantral CSOM. All patients underwent HRCT screening followed by surgical exploration of middle ear cleft. In extent of disease HRCT showed very high sensitivity and specificity for epitympanum (100, 94%) and mesotympanum (98, 98%) areas. It gave valuable information of disease extent in hidden areas like sinus tympani and facial recess of mesotympanum. HRCT satisfactorily delineated malleus and incus erosion but had 75% sensitivity for detecting erosion of stapes suprastructure, though specificity was of 97%. For bony anatomical landmarks HRCT showed very high sensitivity and specificity for detecting erosion of lateral semicircular canal, tegmen tympani and sinus plate. Detection of facial canal erosion on HRCT had moderate sensitivity of 75%. We concluded that routine use of HRCT is justified as a reliable preoperative tool in patients with atticoantral CSOM without intracranial complications and it helps to plan type of surgical intervention. HRCT has limited role to distinguish between granulations and cholesteatoma and also to delineate stapes supra structure and facial nerve canal.
Nebergall, Audrey K; Greene, Meridith E; Rubash, Harry; Malchau, Henrik; Troelsen, Anders; Rolfson, Ola
2016-09-01
The objective of this 13-year prospective evaluation of highly cross-linked ultra high molecular weight polyethylene (HXLPE) was to (1) assess the long-term wear of HXLPE articulating with 2 femoral head sizes using radiostereometric analysis (RSA) and to (2) determine if osteolysis is a concern with this material through the use of plain radiographs and computerized tomography (CT). All patients received a Longevity HXLPE liner with tantalum beads and either a 28-mm or 36-mm femoral head. Twelve patients (6 in each head size group) agreed to return for 13-year RSA, plain radiograph, and CT follow-up. The 1-year and 13-year plain radiographs as well as the CT scans were analyzed for the presence of osteolysis. The 13-year mean ± standard error steady-state wear was 0.05 ± 0.02 mm with no significant increase over time or between the 2 head size groups. Two patients' CT scans showed radiolucent regions in the acetabulum of 4.51 cm(3) and 11.25 cm(3), respectively. In one patient, this area corresponded to a partially healed degenerative cyst treated with autograft during surgery. The second patient had an acetabular protrusio treated with autograft, and the CT scan revealed areas of remodeling of this graft. One patient's 13-year plain radiographs showed evidence of cup loosening and linear radiolucencies in zones 2 and 3. There was no evidence of significant wear over time using RSA. The CT scans did not show evidence of osteolysis due to wear particles. These results suggest that this material has reduced wear compared to conventional polyethylene, irrespective of head size. Copyright © 2016 Elsevier Inc. All rights reserved.
Wangsuphachart, S
1991-12-01
The cost-effectiveness of three alternative policies for the use of intravenous contrast media for urography and enhanced computerized tomography (CT) are analyzed. Alternative #1 is to use high osmolar contrast media (HOCM) in all patients, the historical policy. Alternative #2 is to replace it with low osmolar contrast media (LOCM) in all patients. Alternative #3 is to use LOCM only in the high risk patients. Data on the 6,242 patients who underwent intravenous urography and enhanced CT at the Department of Radiology, Chulalongkorn Hospital in 1989 were used. Both societal and hospital viewpoints were analyzed. The incremental cost-effectiveness (ICE) between #2 and #1 was 26,739 Baht (US$1,070) per healthy day saved (HDS), while the ICE between #3 and #1 was 12,057 Baht (US$482) per HDS. For fatal cases only, ICE between #2 and #1 was 35,111 Baht (US$1,404) per HDS, while the ICE between #3 and #1 was 18,266 Baht (US$731) per HDS. The incremental cost (IC) per patient was 2,341 Baht (US$94) and 681 Baht (US$27) respectively. For the hospital viewpoint the ICE between #2 and #1 was 13,744 (US$550) and between #3 and #1 was 6,127 Baht (US$245) per HDS. The IC per patient was 1,203 Baht (US$48) and 346 Baht (US$14), respectively. From the sensitivity analysis, #3 should be used if the LOCM price is reduced more than 75% (equal to 626 Baht or less) and more than 80% of the patients are able to pay for the contrast media.
Hassani, Hakim; Raynal, Gauthier; Spie, Romain; Daudon, Michel; Vallée, Jean-Noël
2012-05-01
We evaluated the value of combining noncontrast helical computerized tomography (NCHCT) and color Doppler ultrasound in the assessment of the composition of urinary stones. In vitro, we studied 120 stones of known composition, that separate into the five main types: 18 calcium oxalate monohydrate (COM) stones, 41 calcium oxalate dihydrate (COD) stones, 24 uric acid stones, 25 calcium phosphate stones and 12 cystine calculi. Stones were characterized in terms of their Hounsfield density (HU) in NCHCT and the presence of a twinkling artifact (TA) in color Doppler ultrasound. There were statistically significant HU differences between calcium and non-calcium stones (p < 0.001), calcium oxalate stones and calcium phosphate stones (p < 0.001) and uric acid stones and cystine calculi (p < 0.001) but not between COM and COD stones (p = 0.786). Hence, the HU was a predictive factor of the composition of all types of stones, other than for COM and COD stones within the calcium oxalate class (p > 0.05). We found that the TA does not enable differentiation between calcium and non-calcium stones (p > 0.999), calcium oxalate stones and calcium phosphate stones (p = 0.15), or uric acid stones and cystine calculi (p = 0.079). However, it did reveal a significant difference between COM and COD stones (p = 0.002). The absence of a TA is a predictive factor for the presence of COM stones (p = 0.008). Hence, the association of NCHCT and Doppler enables the accurate classification of the five types of stones in vitro. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Conill, Annette L.
Patients receiving Intensity Modulated Radiation Therapy (IMRT) for late stage head and neck (HN) cancer often experience anatomical changes due to weight loss, tumor regression, and positional changes of normal anatomy (1). As a result, the actual dose delivered may vary from the original treatment plan. The purpose of this study was (a) to evaluate the dosimetric consequences of the parotid glands during the course of treatment, and (b) to determine if there would be an optimal timeframe for replanning. Nineteen locally advanced HN cancer patients underwent definitive IMRT. Each patient received an initial computerized tomography simulation (CT-SIM) scan and weekly cone beam computerized tomography (CBCT) scans. A Deformable Image Registration (DIR) was performed between the CT-SIM and CBCT of the parotid glands and Planning Target Volumes (PTVs) using the Eclipse treatment planning system (TPS) and the Velocity deformation software. A recalculation of the dose was performed on the weekly CBCTs using the original monitor units. The parameters for evaluation of our method were: the changes in volume of the PTVs and parotid glands, the dose coverage of the PTVs, the lateral displacement in the Center of Mass (COM), the mean dose, and Normal Tissue Complication Probability (NTCP) of the parotid glands. The studies showed a reduction of the volume in the PTVs and parotids, a medial displacement in COM, and alterations of the mean dose to the parotid glands as compared to the initial plans. Differences were observed for the dose volume coverage of the PTVs and NTCP of the parotid gland values between the initial plan and our proposed method utilizing deformable registration-based dose calculations.
Abiodun, Adeyinka; Atinuke, Agunloye; Yvonne, Osuagwu
2012-01-01
Globally, the most common cause of cranio-facial fractures is road traffic accident (RTA) with computerized tomography (CT) scan as the gold standard in the diagnosis of patients with cranial and facial fractures. The purpose of this study is to assess the pattern of cranial and facial fractures on CT in head injured patients following RTA. Using CT, detailed analyses of 236 patients with head injury following RTA were performed between 2006 and 2008, Data recorded included cause of injury, age and gender distribution, cranial and mid-facial fractures sustained, associated intracranial and soft tissue injury and the types of vehicular accident. The peak age of the patients was between 30 and 39 years. RTA was more common in males than females. Motor-vehicle was the most common cause of RTA in the present study (66.9%). More passengers were involved in the motor vehicle (87.3%) and motorcycle (52.0%) accidents than their corresponding drivers, and they were predominantly males. Majority of the patients involved in pedestrian road traffic accident (PRTA) were motor vehicle victims (93.3%). There were more patients with cranial (59.8%) than mid-facial fractures (40.2%). Majority of the patients had temporal bone cranial fracture (31.1%) and combined or mixed type of mid-facial fractures (41.3%). Intracranial bleeding (31.7%) was the most common associated intracranial finding. RTAs continue to be a menace and are the main cause of craniofacial injury in Nigeria. This pattern of etiologic factors is in accordance with data from most developing countries. Special attention should be paid to reinforcement of legislation and enactment of laws aimed at the reduction of head injury and provision for easy access to CT for the head injured patient.
Computerized tomography-assisted calculation of sinus augmentation volume.
Krennmair, Gerald; Krainhöfner, Martin; Maier, Harald; Weinländer, Michael; Piehslinger, Eva
2006-01-01
This study was intended to calculate the augmentation volume for a sinus lift procedure based on cross-sectional computerized tomography (CT) scans for 2 different augmentation heights. Based on area calculations of cross-sectional CT scans, the volume of additional bone needed was calculated for 44 sinus lift procedures. The amount of bone volume needed to raise the sinus floor to heights of both 12 and 17 mm was calculated. To achieve a sinus floor height of 12 mm, it was necessary to increase the height by a mean of 7.2+/-2.1 mm (range, 3.0 to 10.5 mm), depending on the residual ridge height; to achieve a height of 17 mm, a mean of 12.4+/-2.0 mm (range, 8.5 to 15.5 mm) was required (P < .01). The calculated augmentation volume for an augmentation height of 12 mm was 1.7+/-.9 cm3; for an augmentation height of 17 mm, the volume required was 3.6+/-1.5 cm3. Increasing the height of the sinus lift by 5 mm, ie, from 12 mm to 17 mm augmentation height, increased the augmentation volume by 100%. A significant correlation was found between augmentation height and the calculated sinus lift augmentation volume (r = 0. 78, P < .01). Detailed preoperative knowledge of sinus lift augmentation volume is helpful as a predictive value in deciding on a donor site for harvesting autogenous bone and on the ratio of bone to bone substitute to use. Calculation of the augmentation size can help determine the surgical approach and thus perioperative treatment and the costs of the surgery for both patients and clinicians.
Yuruk, Emrah; Tuken, Murat; Sulejman, Suhejb; Colakerol, Aykut; Serefoglu, Ege Can; Sarica, Kemal; Muslumanoglu, Ahmet Yaser
2017-03-01
To determine the diagnostic value of computerized tomography (CT) in differentiating pyonephrosis from hydronephrosis on the basis of attenuation values (Hounsfield unit-HU). Data of the patients with grades 1-3 hydronephrosis on abdominopelvic CT, who underwent nephrostomy tube placement for decompression of the collecting system, were retrospectively analyzed. Patient demographics and CT findings were recorded along with the first access urine culture results. Three physicians calculated the surface areas and the attenuation values of the dilated collecting systems using the system software. Mean HU of pyonephrosis and hydronephrosis cases was compared. A total of 105 patients with the mean age of 47.7 ± 15.5 (range 20-80) were included. The interclass correlation coefficient of three physicians was 0.981 for HU measurement and 0.999 for calculation of collecting system surface area. Of the patients, 47 (44.8 %) had pyonephrosis. Mean surface areas of the collecting system were similar in patients with pyonephrosis and hydronephrosis (1481.13 ± 1562.94 vs. 1612.94 ± 2261.4 mm 2 , p = 0.735). Urine cultures were positive in all patients with pyonephrosis, whereas 12.7 % of hydronephrosis cases had bacterial in first access urine culture. The HU of the patients with pyonephrosis was significantly higher that that of patients with hydronephrosis (13.51 ± 13.29 vs. 4.67 ± 5.37, p = 0.0001). Having a HU of 9.21 or over diagnosed pyonephrosis accurately with 65.96 % sensitivity and 87.93 % specificity. Measuring attenuation values of the collecting system may be useful to differentiate pyonephrosis from hydronephrosis. Diagnosing pyonephrosis accurately may avoid septic complications.
Baseline Characteristics of Participants in the Randomized National Lung Screening Trial
Aberle, Denise R.; Adams, Amanda M.; Berg, Christine D.; Clapp, Jonathan D.; Clingan, Kathy L.; Gareen, Ilana F.; Marcus, Pamela M.; Pinsky, Paul F.
2010-01-01
Background The National Lung Screening Trial (NLST), a randomized study conducted at 33 US sites, is comparing lung cancer mortality among persons screened with reduced dose helical computerized tomography and among persons screened with chest radiograph. In this article, we present characteristics of the study population. Methods Eligible participants were aged 55–74 years and were current or former smokers with a cigarette smoking history of at least 30 pack-years. Randomization was stratified by site, sex, and age. To assess representativeness of the study population, demographic characteristics of individuals from the general population who met NLST age and smoking history inclusion criteria were obtained from the Tobacco Use Supplement of the US Census Bureau Current Population Surveys. Results The NLST enrolled 53 456 persons, with 26 733 randomly assigned to chest radiograph screening and 26 723 to computerized tomography screening. Characteristics of the participants were as follows: 31 533 (59%) were men, 39 234 (73%) were younger than 65 years, 25 779 (48%) were current smokers, and 16 839 (32%) had a college or higher degree. Median cigarette exposure was 48 pack-years. Among Tobacco Use Supplement respondents who met NLST age and smoking history criteria, 59% were men, 65% were younger than 65 years, and 57% were current smokers. Median cigarette exposure among this group was 47 pack-years, and 14% had a college degree or higher. Conclusion The NLST cohort has a distribution of sex and pack-year history that is similar to the component of the general US population that meets the major NLST eligibility criteria; however, NLST participants are younger, better educated, and less likely to be current smokers. PMID:21119104
Fractional flow reserve by computerized tomography and subsequent coronary revascularization
Packard, René R. Sevag; Li, Dong; Budoff, Matthew J.; Karlsberg, Ronald P.
2017-01-01
Aims Fractional flow reserve by computerized tomography (FFR-CT) provides non-invasive functional assessment of the hemodynamic significance of coronary artery stenosis. We determined the FFR-CT values, receiver operator characteristic (ROC) curves, and predictive ability of FFR-CT for actual standard of care guided coronary revascularization. Methods and results Consecutive outpatients who underwent coronary CT angiography (coronary CTA) followed by invasive angiography over a 24-month period from 2012 to 2014 were identified. Studies that fit inclusion criteria (n = 75 patients, mean age 66, 75% males) were sent for FFR-CT analysis, and results stratified by coronary artery calcium (CAC) scores. Coronary CTA studies were re-interpreted in a blinded manner, and baseline FFR-CT values were obtained retrospectively. Therefore, results did not interfere with clinical decision-making. Median FFR-CT values were 0.70 in revascularized (n = 69) and 0.86 in not revascularized (n = 138) coronary arteries (P < 0.001). Using clinically established significance cut-offs of FFR-CT ≤0.80 and coronary CTA ≥70% stenosis for the prediction of clinical decision-making and subsequent coronary revascularization, the positive predictive values were 74 and 88% and negative predictive values were 96 and 84%, respectively. The area under the curve (AUC) for all studied territories was 0.904 for coronary CTA, 0.920 for FFR-CT, and 0.941 for coronary CTA combined with FFR-CT (P = 0.001). With increasing CAC scores, the AUC decreased for coronary CTA but remained higher for FFR-CT (P < 0.05). Conclusion The addition of FFR-CT provides a complementary role to coronary CTA and increases the ability of a CT-based approach to identify subsequent standard of care guided coronary revascularization. PMID:27469588
Vege, Santhi Swaroop; Fletcher, Joel G; Talukdar, Rupjyoti; Sarr, Michael G
2010-01-01
AIM: To evaluate the ability of contrast-enhanced computerized tomography (CECT) to characterize the nature of peripancreatic collections. METHODS: Twenty five patients with peripancreatic collections on CECT and who underwent operative intervention for severe acute pancreatitis were retrospectively studied. The collections were classified into (1) necrosis without frank pus; (2) necrosis with pus; and (3) fluid without necrosis. A blinded radiologist assessed the preoperative CTs of each patient for necrosis and peripancreatic fluid collections. Peripancreatic collections were described in terms of volume, location, number, heterogeneity, fluid attenuation, wall perceptibility, wall enhancement, presence of extraluminal gas, and vascular compromise. RESULTS: Fifty-four collections were identified at operation, of which 45 (83%) were identified on CECT. Of these, 25/26 (96%) had necrosis without pus, 16/19 (84%) had necrosis with pus, and 4/9 (44%) had fluid without necrosis. Among the study characteristics, fluid heterogeneity was seen in a greater proportion of collections in the group with necrosis and pus, compared to the other two groups (94% vs 48% and 25%, P = 0.002 and 0.003, respectively). Among the wall characteristics, irregularity was seen in a greater proportion of collections in the groups with necrosis with and without pus, when compared to the group with fluid without necrosis (88% and 71% vs 25%, P = 0.06 and P < 0.01, respectively). The combination of heterogeneity and presence of extraluminal gas had a specificity and positive likelihood ratio of 92% and 5.9, respectively, in detecting pus. CONCLUSION: Most of the peripancreatic collections seen on CECT in patients with severe acute pancreatitis who require operative intervention contain necrotic tissue. CECT has a somewhat limited role in differentiating the different types of collections. PMID:20818812
Foda, Khaled; Abdeldaeim, Hussein; Youssif, Mohamed; Assem, Akram
2013-11-01
To define the parameters that accompanied a successful extracorporeal shock wave lithotripsy (ESWL), namely the number of shock waves (SWs), expulsion time (ET), mean stone density (MSD), and the skin-to-stone distance (SSD). A total of 368 patients diagnosed with renal calculi using noncontrast computerized tomography had their MSD, diameter, and SSD recorded. All patients were treated using a Siemens lithotripter. ESWL success meant a stone-free status or presence of residual fragments <3 mm, ET was the time in days for the successful clearance of stone fragments. Correlation was performed between the stone characteristics, number of SWs, and ET. Two multiple regression analysis models defined the number of SWs and ET. Two receiver operating characteristic curves plotted the best MSD cutoff value and optimum SSD for a successful ESWL. Three hundred one patients were ESWL successes. A significant positive correlation was elicited between number of SWs and stone diameter, density and SSD; between ET and stone diameter and density. Multiple regressions concluded 2 equations: Number of SWs = 265.108 + 5.103 x1 + 22.39 x2 + 10.931 x3 ET (days) = -10.85 + 0.031 x1 + 2.11 x2 x1 = stone density (Hounsfield unit [HUs]), x2 = stone diameter (mm), and x3 = SSD (mm). Receiver operating characteristic curves demonstrated a cutoff value of ≤ 934 HUs with 94.4% sensitivity and 66.7% specificity and P = .0211. The SSD curve showed that a distance ≤ 99 mm was 85.7% sensitive, 87.5% specific, P <.0001. Stone disintegration is not recommended if MSD is >934 HUs and SSD >99 mm. The required number of SWs and the expected ET can be anticipated. Copyright © 2013 Elsevier Inc. All rights reserved.
Model-based registration for assessment of spinal deformities in idiopathic scoliosis
NASA Astrophysics Data System (ADS)
Forsberg, Daniel; Lundström, Claes; Andersson, Mats; Knutsson, Hans
2014-01-01
Detailed analysis of spinal deformity is important within orthopaedic healthcare, in particular for assessment of idiopathic scoliosis. This paper addresses this challenge by proposing an image analysis method, capable of providing a full three-dimensional spine characterization. The proposed method is based on the registration of a highly detailed spine model to image data from computed tomography. The registration process provides an accurate segmentation of each individual vertebra and the ability to derive various measures describing the spinal deformity. The derived measures are estimated from landmarks attached to the spine model and transferred to the patient data according to the registration result. Evaluation of the method provides an average point-to-surface error of 0.9 mm ± 0.9 (comparing segmentations), and an average target registration error of 2.3 mm ± 1.7 (comparing landmarks). Comparing automatic and manual measurements of axial vertebral rotation provides a mean absolute difference of 2.5° ± 1.8, which is on a par with other computerized methods for assessing axial vertebral rotation. A significant advantage of our method, compared to other computerized methods for rotational measurements, is that it does not rely on vertebral symmetry for computing the rotational measures. The proposed method is fully automatic and computationally efficient, only requiring three to four minutes to process an entire image volume covering vertebrae L5 to T1. Given the use of landmarks, the method can be readily adapted to estimate other measures describing a spinal deformity by changing the set of employed landmarks. In addition, the method has the potential to be utilized for accurate segmentations of the vertebrae in routine computed tomography examinations, given the relatively low point-to-surface error.
A 10-Year Retrospective Review of Nephrolithiasis in the Navy and Navy Pilots.
Masterson, James H; Phillips, Christopher J; Crum-Cianflone, Nancy F; Krause, Robert J; Sur, Roger L; L'Esperance, James O
2017-08-01
Little is known about the incidence of nephrolithiasis in the United States Navy. Navy pilots must be kidney stone-free and are often referred for treatment of small asymptomatic stones. The primary objectives of this study were to determine the incidence of nephrolithiasis and computerized tomography, proportion undergoing treatment and incidence of stone related mishaps in Navy pilots compared with other Navy personnel. We retrospectively studied the records of all Navy service members from 2002 to 2011 for nephrolithiasis based on ICD-9 stone codes to determine the mentioned rates. We also reviewed NSC (Naval Safety Center) data for a history of accidents associated with nephrolithiasis. Rates of disease were calculated using person-years of followup and inferential statistics were done using univariable and multivariable analyses. We evaluated 667,840 Navy personnel with a total of 3,238,331 person-years of followup. The annual incidence of nephrolithiasis was 240/100,000 person-years with a 5-year recurrence rate of 35.3%. On multivariable analysis pilots had nephrolithiasis incidence and treatment rates similar to those of the overall Navy population. Women had a higher incidence of nephrolithiasis compared with men (OR 1.17, p <0.0001). The rate of computerized tomography was lower in pilots than in the rest of the Navy (39 vs 66/10,000 person-years, p <0.0001). No recorded accidents were associated with kidney stones. Navy pilots had a similar incidence of nephrolithiasis and were no more likely to undergo a surgical procedure. Given that no accidents were associated with nephrolithiasis, this study suggests reconsidering current military policies necessitating pilots to be completely stone-free. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Song, Ha Tae; Kim, Young Jun; Lee, Soo Jung; Moon, Yeon Sung
2007-09-01
To investigate relationships between age, weight, refractive error, and morphologic changes in children's eyes by computerized tomography (CT). Of the 772 eyes of 386 patients under the age of 20 years, who visited our Department of Ophthalmology between January 2005 to August 2006 and underwent CT of the orbit, 406 eyes of 354 patients with clear CT images and normal eyeball contour were enrolled in the present retrospective study. The axial lengths, widths, horizontal and vertical lengths, refractive errors, and body weight of eyes were measured, and relationship between these parameters were investigated. Axial length was found to correlate significantly with eye width (r=0.914), and in emmetropic eyes and myopic eyes, axial lengths and widths were found to increase as age and body weight increased. Axial lengths increased rapidly until age 10, and then increased slowly. In emmetropic eyes, widths/axial lengths increased with age, but in myopic eyes these decreased as age or severity of myopia increased. Moreover, as age increased, the myopic population and severity also increased. The axial length was longer in case of myopia compared to emmetropia in all age groups and there was almost no difference in the increase rate of axial length by the age of myopia and emmetropia. However, the width was wider in case of myopia compared to emmetropia in all age groups and the increase rate of width in myopia by age was smaller than that of emmetropia. Myopia showed decreasing rate of width/axial length with increase of age, from 1.004 in 5 years to 0.971 in 20 years. However, emmetropia showed increasing rate of width/axial length with increase of age, from 0.990 in 5 years to 1.006 in 20 years.
Relations between Age, Weight, Refractive Error and Eye Shape by Computerized Tomography in Children
Song, Ha Tae; Kim, Young Jun; Lee, Soo Jung
2007-01-01
Purpose To investigate relationships between age, weight, refractive error, and morphologic changes in children's eyes by computerized tomography (CT). Methods Of the 772 eyes of 386 patients under the age of 20 years, who visited our Department of Ophthalmology between January 2005 to August 2006 and underwent CT of the orbit, 406 eyes of 354 patients with clear CT images and normal eyeball contour were enrolled in the present retrospective study. The axial lengths, widths, horizontal and vertical lengths, refractive errors, and body weight of eyes were measured, and relationship between these parameters were investigated. Results Axial length was found to correlate significantly with eye width (r=0.914), and in emmetropic eyes and myopic eyes, axial lengths and widths were found to increase as age and body weight increased. Axial lengths increased rapidly until age 10, and then increased slowly. In emmetropic eyes, widths / axial lengths increased with age, but in myopic eyes these decreased as age or severity of myopia increased. Moreover, as age increased, the myopic population and severity also increased. Conclusions The axial length was longer in case of myopia compared to emmetropia in all age groups and there was almost no difference in the increase rate of axial length by the age of myopia and emmetropia. However, the width was wider in case of myopia compared to emmetropia in all age groups and the increase rate of width in myopia by age was smaller than that of emmetropia. Myopia showed decreasing rate of width/axial length with increase of age, from 1.004 in 5 years to 0.971 in 20 years. However, emmetropia showed increasing rate of width/axial length with increase of age, from 0.990 in 5 years to 1.006 in 20 years. PMID:17804923
A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.
Ertan, Koray; Taraghinia, Soheil; Sadeghi, Alireza; Atalar, Ergin
2018-07-01
Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. Two different field design methods are formulated to solve for the required current values of the gradient array elements for the given slice locations. The method requirements are specified, optimization problems are formulated for the minimum current norm and an analytical solution is provided. A 9-channel z-gradient coil array driven by independent, custom-designed gradient amplifiers is used to validate the theory. Performance measures such as normalized slice thickness error, gradient strength per unit norm current, power dissipation, and maximum amplitude of the magnetic field are provided for various slice locations and numbers of slices. Two and 3 slices are excited by a single-band RF pulse in simulations and phantom experiments. The possibility of multi-slice excitation with a single-band RF pulse using a z-gradient array is validated in simulations and phantom experiments. Magn Reson Med 80:400-412, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Development of Multi-slice Analytical Tool to Support BIM-based Design Process
NASA Astrophysics Data System (ADS)
Atmodiwirjo, P.; Johanes, M.; Yatmo, Y. A.
2017-03-01
This paper describes the on-going development of computational tool to analyse architecture and interior space based on multi-slice representation approach that is integrated with Building Information Modelling (BIM). Architecture and interior space is experienced as a dynamic entity, which have the spatial properties that might be variable from one part of space to another, therefore the representation of space through standard architectural drawings is sometimes not sufficient. The representation of space as a series of slices with certain properties in each slice becomes important, so that the different characteristics in each part of space could inform the design process. The analytical tool is developed for use as a stand-alone application that utilises the data exported from generic BIM modelling tool. The tool would be useful to assist design development process that applies BIM, particularly for the design of architecture and interior spaces that are experienced as continuous spaces. The tool allows the identification of how the spatial properties change dynamically throughout the space and allows the prediction of the potential design problems. Integrating the multi-slice analytical tool in BIM-based design process thereby could assist the architects to generate better design and to avoid unnecessary costs that are often caused by failure to identify problems during design development stages.
Phase-sensitive dual-inversion recovery for accelerated carotid vessel wall imaging.
Bonanno, Gabriele; Brotman, David; Stuber, Matthias
2015-03-01
Dual-inversion recovery (DIR) is widely used for magnetic resonance vessel wall imaging. However, optimal contrast may be difficult to obtain and is subject to RR variability. Furthermore, DIR imaging is time-inefficient and multislice acquisitions may lead to prolonged scanning times. Therefore, an extension of phase-sensitive (PS) DIR is proposed for carotid vessel wall imaging. The statistical distribution of the phase signal after DIR is probed to segment carotid lumens and suppress their residual blood signal. The proposed PS-DIR technique was characterized over a broad range of inversion times. Multislice imaging was then implemented by interleaving the acquisition of 3 slices after DIR. Quantitative evaluation was then performed in healthy adult subjects and compared with conventional DIR imaging. Single-slice PS-DIR provided effective blood-signal suppression over a wide range of inversion times, enhancing wall-lumen contrast and vessel wall conspicuity for carotid arteries. Multislice PS-DIR imaging with effective blood-signal suppression is enabled. A variant of the PS-DIR method has successfully been implemented and tested for carotid vessel wall imaging. This technique removes timing constraints related to inversion recovery, enhances wall-lumen contrast, and enables a 3-fold increase in volumetric coverage at no extra cost in scanning time.
Single photon emission computed tomography (SPECT) in epilepsy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leroy, R.F.
1991-12-31
Epilepsy is a common neurologic disorder which has just begun to be studied with single photon emission computerized tomography (SPECT). Epilepsy usually is studied with electroencephalographic (EEG) techniques that demonstrate the physiologic changes that occur during seizures, and with neuroimaging techniques that show the brain structures where seizures originate. Neither method alone has been adequate to describe the pathophysiology of the patient with epilepsy. EEG techniques lack anatomic sensitivity, and there are no structural abnormalities shown by neuroimaging which are specific for epilepsy. Functional imaging (FI) has developed as a physiologic tool with anatomic sensitivity, and SPECT has been promotedmore » as a FI technique because of its potentially wide availability. However, SPECT is early in its development and its clinical utility for epilepsy still has to be demonstrated. To understand this role of SPECT, consideration must be given to the pathophysiology of epilepsy, brain physiology, types of seizure, epileptic syndromes, and the SPECT technique itself. 44 refs., 2 tabs.« less
NECTAR—A fission neutron radiography and tomography facility
NASA Astrophysics Data System (ADS)
Bücherl, T.; Lierse von Gostomski, Ch.; Breitkreutz, H.; Jungwirth, M.; Wagner, F. M.
2011-09-01
NECTAR (Neutron Computerized Tomography and Radiography) is a versatile facility for radiographic and tomographic investigations as well as for neutron activation experiments using fission neutrons. The radiation sources for this facility are two plates of highly enriched uranium situated in the moderator vessel in FRM II. Thermal neutrons originating from the main fuel element of the reactor generate in these plates fast neutrons. These can escape through a horizontal beam tube without moderation. The beam can be filtered and manipulated in order to reduce the accompanying gamma radiation and to match the specific experimental tasks. A summary of the main parameters required for experimental set-up and (quantitative) data evaluation is presented. The (measured) spectra of the neutron and gamma radiations are shown along with the effect of different filters on their behavior. The neutron and gamma fluxes, dose rates, L/ D-ratios, etc. and the main parameters of the actually used detection systems for neutron imaging are given, too.
Kamaleshwaran, Koramadai Karuppusamy; Rajamani, Venkataraman; Krishnan, Boopathi; Mallia, Madhav; Kalarikal, Radhakrishnan; Mohanan, Vyshakh; Shinto, Ajit Sugunan
2015-01-01
Rheumatoid arthritis (RA) is a chronic disease that is mainly characterized by the asymmetric erosive synovitis, particularly affecting peripheral joints. Radiation synovectomy or radiosynovectomy (RSV), also known as radiosynoviorthesis was first described in 1950's as an adjuvant treatment for RA. RSV is based on the irradiation of the joint synovium by the intra-articular administration of various β-emitting radiopharmaceuticals. As a generator-produced β-emitting radionuclide, the importance of rhenium-188 (Re-188) for radionuclide therapy is increasing rapidly. There are previous reports which used Re-188 tin colloid in knee joint synovitis, but use of Re-188 tin colloid in small joint is not yet reported. We describe the use of Re-188 tin colloid in a 45-year-old female who presented with right 4(th) proximal interphalangeal joint synovitis due to rheumatoid arthritis.
Pino Rivero, V; Pantoja Hernández, C G; González Palomino, A; Trinidad Ruíz, G; Marcos García, M; Keituqwa Yáñez, T; Pardo Romero, G; Blasco Huelva, A
2005-01-01
Sonnography and Tc-99m sestamibi scintigraphy are the most requested preoperative imaging tests nowdays in the surgery of hyperparathyroidism. The aim of our article is to know if Computerized Tomography (CT) and Magnetic Resonance Imaging (MRI) are useful as a location study and in which cases it would be more justified to ask these radiologic techniques. For that we report our results with 29 patients at all diagnosed as hyperparathyroidism (26 primary forms and 3 secondary ones) and operated by our E.N.T. Department later. On 20 of them a cervical CT was asked before the parathyroidectomy and on the rest 9, a MRI with sensitivities of 65% and 88.9% respectively. We think both complementary explorations must not be solicited by routine but they can represent a help in the cases in that sonnography and scintigraphy are not able to show the possible adenoma or hiperplasia, particularly in recurrent hyperparathyroidisms, reinterventions or suspect of parathyroid glands in an atypical location.
Brain imaging and behavioral outcome in traumatic brain injury.
Bigler, E D
1996-09-01
Brain imaging studies have become an essential diagnostic assessment procedure in evaluating the effects of traumatic brain injury (TBI). Such imaging studies provide a wealth of information about structural and functional deficits following TBI. But how pathologic changes identified by brain imaging methods relate to neurobehavioral outcome is not as well known. Thus, the focus of this article is on brain imaging findings and outcome following TBI. The article starts with an overview of current research dealing with the cellular pathology associated with TBI. Understanding the cellular elements of pathology permits extrapolation to what is observed with brain imaging. Next, this article reviews the relationship of brain imaging findings to underlying pathology and how that pathology relates to neurobehavioral outcome. The brain imaging techniques of magnetic resonance imaging, computerized tomography, and single photon emission computed tomography are reviewed. Various image analysis procedures, and how such findings relate to neuropsychological testing, are discussed. The importance of brain imaging in evaluating neurobehavioral deficits following brain injury is stressed.
[Human neurocysticercosis in Baixada Fluminense, Rio de Janeiro State, Brazil].
Mendes, Ernani Costa; da Silva, Scintilla Santos; Fonseca, Edson Alexandre La' Terza; de Souza, Hilana Regina Ribeiro; de Carvalho, Raimundo Wilson
2005-12-01
The objective of this manuscript was to know the neurocysticercosis prevalence and some epidemiological aspects in Baixada Fluminense, State of Rio de Janeiro, Brazil. The data came from the service of computerized tomography of the Nova Iguaçu General Hospital from 1996 to 2002 and from neuroimage "D'IMAGEM" Center from 1992 to 2002. We analyzed 36,379 tomographies identifying 72 cases of the parasitoses, the majority in women (62.5%, p>0.05) and in the chronic phase (93.1%). The neurocysticercosis had occurred in all age groups and increase with age (r=0.84, p<0.05), being that 45.8% of them up to 50 years. The 20 interviewed cases were origin from several municipal districts of Baixada Fluminense, the monthly per capita income was 366 R dollars. The growing urbanization, deficient sanitary vigilance, absence of sewage systems and sanitary education are the main factors that potentially the transmission of cysticercosis and taeniasis in the Baixada Fluminense.
Atelectasis observed by computerized tomography after Caesarean section.
Meira, M N C; Carvalho, C R R; Galizia, M S; Borges, J B; Kondo, M M; Zugaib, M; Vieira, J E
2010-06-01
Atelectasis after either vaginal or Caesarean delivery has not been adequately quantified. This study addresses the hypothesis that atelectasis may be worse in women who undergo Caesarean section when compared with vaginal delivery under regional anaesthesia. Twenty healthy non-smoking women submitted to a chest computed tomography (CT) 2 h after delivery in a University Hospital, who had experienced vaginal delivery (n=10) under combined spinal-epidural analgesia or a Caesarean section (n=10) under spinal anaesthesia, were evaluated. The percentage cross-sectional area of atelectasis in dependent lung regions were measured from the CT images obtained at cross-section of the xiphoid process and the top of the diaphragm. The percentage cross-sectional area of atelectasis was 3.95% in the vaginal delivery group and 14.1% in the Caesarean group (P<0.001, Mann-Whitney rank sum test). These results suggested that pulmonary atelectasis is greater after Caesarean section delivery under spinal anaesthesia than after vaginal delivery with combined spinal-epidural analgesia.
Babu, Kalpana; Shukla, Sai Bhakti; Philips, Mariamma
2017-04-01
To review the role of high resolution chest computed tomography (HRCT) in ocular sarcoidosis in a high TB endemic population. This was a retrospective study. Out of 140 cases, 54 had ocular sarcoidosis, while 86 cases had ocular tuberculosis. Abnormal HRCT findings was noted in 52 cases (96.3%) of ocular sarcoidosis compared with 55 cases (64.7%) of ocular tuberculosis (p = 0.001). Mediastinal lymphadenopathy was the most common finding in both groups (p = 0.544). Hilar lymphadenopathy and fissural nodules were significantly seen in ocular sarcoidosis (p = 0.001). Necrosis was seen in three cases of ocular sarcoidosis. In nearly half of the cases, it was not possible to differentiate between sarcoidosis and tuberculosis on HRCT. HRCT is a useful diagnostic tool in ocular sarcoidosis. Bilateral hilar lymphadenopathy and fissural nodules are significant findings in ocular sarcoidosis. A confident diagnosis of ocular sarcoidosis is made by the amalgamation of results of clinical, radiologic, and other laboratory investigations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bie, B. X.; Huang, J. Y.; Fan, D.
Uniaxial tensile experiments are conducted on a T700 carbon fiber/epoxy composite along various offaxis angles. Stressestrain curves are measured along with strain fields mapped via synchrotron x-ray digital image correlation, as well as computerized tomography. Elastic modulus and tensile strength decrease with increasing off-axis angles, while fracture strain exhibits a nonmonotonic trend as a combined result of tensile strength decrease and fracture mode transition. At high off-axis angles, strain field mapping demonstrates distinct tensile and shear strain localizations and deformation bands approximately along the fiber directions, while deformation is mainly achieved via continuous growth of tensile strain at low off-axismore » angles. Roughness of fracture planes decreases exponentially as the off-axis angle increases. The stressestrain curves, strain fields, tomography and fractographs show consistent features, and reveal a fracture mode transition from mainly tension (fiber fracture) to in-plane shear (interface debonding).« less
Park, Sang Cheol; Leader, Joseph Ken; Tan, Jun; Lee, Guee Sang; Kim, Soo Hyung; Na, In Seop; Zheng, Bin
2011-01-01
This article presents a new computerized scheme that aims to accurately and robustly separate left and right lungs on computed tomography (CT) examinations. We developed and tested a method to separate the left and right lungs using sequential CT information and a guided dynamic programming algorithm using adaptively and automatically selected start point and end point with especially severe and multiple connections. The scheme successfully identified and separated all 827 connections on the total 4034 CT images in an independent testing data set of CT examinations. The proposed scheme separated multiple connections regardless of their locations, and the guided dynamic programming algorithm reduced the computation time to approximately 4.6% in comparison with the traditional dynamic programming and avoided the permeation of the separation boundary into normal lung tissue. The proposed method is able to robustly and accurately disconnect all connections between left and right lungs, and the guided dynamic programming algorithm is able to remove redundant processing.
Computerized Dead-Space Volume Measurement of Face Masks Applied to Simulated Faces.
Amirav, Israel; Luder, Anthony S; Halamish, Asaf; Marzuk, Chatib; Daitzchman, Marcelo; Newhouse, Michael T
2015-09-01
The dead-space volume (VD) of face masks for metered-dose inhaler treatments is particularly important in infants and young children with asthma, who have relatively low tidal volumes. Data about VD have been traditionally obtained from water displacement measurements, in which masks are held against a flat surface. Because, in real life, masks are placed against the face, VD is likely to differ considerably between masks depending upon their contour and fit. The aim of this study was to develop an accurate and reliable way to measure VD electronically and to apply this technique by comparing the electronic VD of commonly available face masks. Average digital faces were obtained from 3-dimensional images of 270 infants and children. Commonly used face masks (small and medium) from various manufacturers (Monaghan Medical, Pari Respiratory Equipment, Philips Respironics, and InspiRx) were scanned and digitized by means of computed tomography. Each mask was electronically applied to its respective digital face, and the VD enclosed (mL) was computerized and precisely measured. VD varied between 22.6 mL (SootherMask, InspiRx) and 43.1 mL (Vortex, Pari) for small masks and between 41.7 mL (SootherMask) and 71.5 mL (AeroChamber, Monaghan Medical) for medium masks. These values were significantly lower and less variable than measurements obtained by water displacement. Computerized techniques provide an innovative and relatively simple way of accurately measuring the VD of face masks applied to digital faces. As determined by computerized measurement using average-size virtual faces, the InspiRx masks had a significantly smaller VD for both small and medium masks compared with the other masks. This is of considerable importance with respect to aerosol dose and delivery time, particularly in young children. (ClinicalTrials.gov registration NCT01274299.). Copyright © 2015 by Daedalus Enterprises.
Perdekamp, Markus Grosse; Kneubuehl, Beat P; Ishikawa, Takaki; Nadjem, Hadi; Kromeier, Jan; Pollak, Stefan; Thierauf, Annette
2010-11-01
Apart from one article published by Rabl and Sigrist in 1992 (Rechtsmedizin 2:156-158), there are no further reports on secondary skull fractures in shots from captive bolt guns. Up to now, the pertinent literature places particular emphasis on the absence of indirect lesions away from the impact point, when dealing with the wounding capacity of slaughterer's guns. The recent observation of two suicidal head injuries accompanied by skull fractures far away from the bolt's path gave occasion to experimental studies using simulants (glycerin soap, balls from gelatin) and skull–brain models. As far as ballistic soap was concerned, the dimensions of the bolt's channel were assessed by multi-slice computed tomography before cutting the blocks open. The test shots to gelatin balls and to skull-brain models were documented by means of a high-speed motion camera. As expected, the typical temporary cavity effect of bullets fired from conventional guns could not be observed when captive bolt stunners were discharged. Nevertheless, the visualized transfer of kinetic energy justifies the assumption that the secondary fractures seen in thin parts of the skull were caused by a hydraulic burst effect.
[Non-biological 3D printed simulator for training in percutaneous nephro- lithotripsy].
Alyaev, Yu G; Sirota, E S; Bezrukov, E A; Ali, S Kh; Bukatov, M D; Letunovskiy, A V; Byadretdinov, I Sh
2018-03-01
To develop a non-biological 3D printed simulator for training and preoperative planning in percutaneous nephrolithotripsy (PCNL), which allows doctors to master and perform all stages of the operation under ultrasound and fluoroscopy guidance. The 3D model was constructed using multislice spiral computed tomography (MSCT) images of a patient with staghorn urolithiasis. The MSCT data were processed and used to print the model. The simulator consisted of two parts: a non-biological 3D printed soft model of a kidney with reproduced intra-renal vascular and collecting systems and a printed 3D model of a human body. Using this 3D printed simulator, PCNL was performed in the interventional radiology operating room under ultrasound and fluoroscopy guidance. The designed 3D printed model of the kidney completely reproduces the individual features of the intra-renal structures of the particular patient. During the training, all the main stages of PCNL were performed successfully: the puncture, dilation of the nephrostomy tract, endoscopic examination, intra-renal lithotripsy. Our proprietary 3D-printed simulator is a promising development in the field of endourologic training and preoperative planning in the treatment of complicated forms of urolithiasis.
Customized Polymethyl Methacrylate Implants for the Reconstruction of Craniofacial Osseous Defects
Fernandes da Silva, André Luis; Borba, Alexandre Meireles; Simão, Niverso Rodrigues; Pedro, Fábio Luis Miranda
2014-01-01
Craniofacial defects represent alterations in the anatomy and morphology of the cranial vault and the facial bones that potentially affect an individual's psychological and social well-being. Although a variety of techniques and restorative procedures have been described for the reconstruction of the affected area, polymethyl methacrylate (PMMA), a biocompatible and nondegradable acrylic resin-based implant, is the most widely used alloplastic material for such craniomaxillofacial reconstruction. The aim of this study was to describe a technique for aesthetic and functional preoperative customized reconstruction of craniofacial bone defects from a small series of patients offered by the Brazilian public health system. Three adult male patients attended consultation with chief complaints directly related to their individual craniofacial bone defects. With the aid of multislice computed tomography scans and subsequent fabrication of the three-dimensional craniofacial prototype, custom-made PMMA implants were fabricated preoperatively. Under general anesthesia, with access to the craniofacial defects with a coronal approach, the PMMA implants were adapted and fixated to the facial skeleton with titanium plates and screws. Postoperative evaluation demonstrated uneventful recovery and an excellent aesthetic result. Customized prefabricated PMMA implants manufactured over the rapid prototyping models proved to be effective and feasible. PMID:25093139
Customized polymethyl methacrylate implants for the reconstruction of craniofacial osseous defects.
Fernandes da Silva, André Luis; Borba, Alexandre Meireles; Simão, Niverso Rodrigues; Pedro, Fábio Luis Miranda; Borges, Alvaro Henrique; Miloro, Michael
2014-01-01
Craniofacial defects represent alterations in the anatomy and morphology of the cranial vault and the facial bones that potentially affect an individual's psychological and social well-being. Although a variety of techniques and restorative procedures have been described for the reconstruction of the affected area, polymethyl methacrylate (PMMA), a biocompatible and nondegradable acrylic resin-based implant, is the most widely used alloplastic material for such craniomaxillofacial reconstruction. The aim of this study was to describe a technique for aesthetic and functional preoperative customized reconstruction of craniofacial bone defects from a small series of patients offered by the Brazilian public health system. Three adult male patients attended consultation with chief complaints directly related to their individual craniofacial bone defects. With the aid of multislice computed tomography scans and subsequent fabrication of the three-dimensional craniofacial prototype, custom-made PMMA implants were fabricated preoperatively. Under general anesthesia, with access to the craniofacial defects with a coronal approach, the PMMA implants were adapted and fixated to the facial skeleton with titanium plates and screws. Postoperative evaluation demonstrated uneventful recovery and an excellent aesthetic result. Customized prefabricated PMMA implants manufactured over the rapid prototyping models proved to be effective and feasible.
Chronic Contained Rupture of an Abdominal Aortic Aneurysm: From Diagnosis to Endovascular Resolution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gandini, Roberto, E-mail: marcello.chiocchi@fastwebnet.it; Chiocchi, Marcello; Maresca, Luciano
2008-07-15
A male patient, 69 years old, presented with fever, leucocytosis, and persistent low back pain; he also had an abdominal aortic aneurysm (AAA), as previously diagnosed by Doppler UltraSound (US), and was admitted to our hospital. On multislice computed tomography (msCT), a large abdominal mass having no definite border and involving the aorta and both of the psoas muscles was seen. This mass involved the forth-lumbar vertebra with lysis, thus simulating AAA rupture into a paraspinal collection; it was initially considered a paraspinal abscess. After magnetic resonance imaging examination and culture of the fluid aspirated from the mass, no infectivemore » organisms were found; therefore, a diagnosisof chronically contained AAA rupture was made, and an aortic endoprosthesis was subsequently implanted. The patient was discharged with decreased lumbar pain. At 12-month follow-up, no evidence of leakage was observed. To our knowledge, this is the first case of endoprosthesis implantation in a patient, who was a poor candidate for surgical intervention due to renal failure, leucocytosis and high fever, having a chronically contained AAA ruptured simulatingspodilodiscitis abscess. Appropriate diagnosis and therapy resolved potentially crippling pathology and avoided surgical graft-related complications.« less
[State of the art and future trends in technology for computed tomography dose reduction].
Calzado Cantera, A; Hernández-Girón, I; Salvadó Artells, M; Rodríguez González, R
2013-12-01
The introduction of helical and multislice acquisitions in CT scanners together with decreased image reconstruction times has had a tremendous impact on radiological practice. Technological developments in the last 10 to 12 years have enabled very high quality images to be obtained in a very short time. Improved image quality has led to an increase in the number of indications for CT. In parallel to this development, radiation exposure in patients has increased considerably. Concern about the potential health risks posed by CT imaging, reflected in diverse initiatives and actions by official organs and scientific societies, has prompted the search for ways to reduce radiation exposure in patients without compromising diagnostic efficacy. To this end, good practice guidelines have been established, special applications have been developed for scanners, and research has been undertaken to optimize the clinical use of CT. Noteworthy technical developments incorporated in scanners include the different modes of X-ray tube current modulation, automatic selection of voltage settings, selective organ protection, adaptive collimation, and iterative reconstruction. The appropriate use of these tools to reduce radiation doses requires thorough knowledge of how they work. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
Bolliger, Stephan A; Thali, Michael J; Ross, Steffen; Buck, Ursula; Naether, Silvio; Vock, Peter
2008-02-01
The transdisciplinary research project Virtopsy is dedicated to implementing modern imaging techniques into forensic medicine and pathology in order to augment current examination techniques or even to offer alternative methods. Our project relies on three pillars: three-dimensional (3D) surface scanning for the documentation of body surfaces, and both multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) to visualise the internal body. Three-dimensional surface scanning has delivered remarkable results in the past in the 3D documentation of patterned injuries and of objects of forensic interest as well as whole crime scenes. Imaging of the interior of corpses is performed using MSCT and/or MRI. MRI, in addition, is also well suited to the examination of surviving victims of assault, especially choking, and helps visualise internal injuries not seen at external examination of the victim. Apart from the accuracy and three-dimensionality that conventional documentations lack, these techniques allow for the re-examination of the corpse and the crime scene even decades later, after burial of the corpse and liberation of the crime scene. We believe that this virtual, non-invasive or minimally invasive approach will improve forensic medicine in the near future.
Peripleural lung disease detection based on multi-slice CT images
NASA Astrophysics Data System (ADS)
Matsuhiro, M.; Suzuki, H.; Kawata, Y.; Niki, N.; Nakano, Y.; Ohmatsu, H.; Kusumoto, M.; Tsuchida, T.; Eguchi, K.; Kaneko, M.
2015-03-01
With the development of multi-slice CT technology, obtaining accurate 3D images of lung field in a short time become possible. To support that, a lot of image processing methods need to be developed. Detection peripleural lung disease is difficult due to its existence out of lung region, because lung extraction is often performed based on threshold processing. The proposed method uses thoracic inner region extracted by inner cavity of bone as well as air region, covers peripleural lung diseased cases such as lung nodule, calcification, pleural effusion and pleural plaque. We applied this method to 50 cases including 39 peripleural lung diseased cases. This method was able to detect 39 peripleural lung disease with 2.9 false positive per case.
High-speed multislice T1 mapping using inversion-recovery echo-planar imaging.
Ordidge, R J; Gibbs, P; Chapman, B; Stehling, M K; Mansfield, P
1990-11-01
Tissue contrast in MR images is a strong function of spin-lattice (T1) and spin-spin (T2) relaxation times. However, the T1 relaxation time is rarely quantified because of the long scan time required to produce an accurate T1 map of the subject. In a standard 2D FT technique, this procedure may take up to 30 min. Modifications of the echo-planar imaging (EPI) technique which incorporate the principle of inversion recovery (IR) enable multislice T1 maps to be produced in total scan times varying from a few seconds up to a minute. Using IR-EPI, rapid quantification of T1 values may thus lead to better discrimination between tissue types in an acceptable scan time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barrier, Pierre, E-mail: p.barrier@gmail.com; Otal, Philippe; Garcia, Olivier
Fistulas complicating an abdominal aortic aneurysm (AAA) are rare, and fistulas involving the left renal vein are particularly uncommon. We highlight here a fistula between an infrarenal aortic aneurysm and a retroaortic left renal vein, revealed by left flank pain associated with hematuria and acute renal failure. The multislice CT angiography performed in this 68-year-old patient revealed communication and equal enhancement between the aorta and the left gonadic vein, suggesting the presence of a fistula. The three-dimensional VRT reconstructions presented in this case were of great value in the preoperative planning, enabling immediate visualization of this unusual feature. Alternative diagnosesmore » to consider when encountering this clinical presentation are reviewed.« less
A fast image simulation algorithm for scanning transmission electron microscopy.
Ophus, Colin
2017-01-01
Image simulation for scanning transmission electron microscopy at atomic resolution for samples with realistic dimensions can require very large computation times using existing simulation algorithms. We present a new algorithm named PRISM that combines features of the two most commonly used algorithms, namely the Bloch wave and multislice methods. PRISM uses a Fourier interpolation factor f that has typical values of 4-20 for atomic resolution simulations. We show that in many cases PRISM can provide a speedup that scales with f 4 compared to multislice simulations, with a negligible loss of accuracy. We demonstrate the usefulness of this method with large-scale scanning transmission electron microscopy image simulations of a crystalline nanoparticle on an amorphous carbon substrate.
A fast image simulation algorithm for scanning transmission electron microscopy
Ophus, Colin
2017-05-10
Image simulation for scanning transmission electron microscopy at atomic resolution for samples with realistic dimensions can require very large computation times using existing simulation algorithms. Here, we present a new algorithm named PRISM that combines features of the two most commonly used algorithms, namely the Bloch wave and multislice methods. PRISM uses a Fourier interpolation factor f that has typical values of 4-20 for atomic resolution simulations. We show that in many cases PRISM can provide a speedup that scales with f 4 compared to multislice simulations, with a negligible loss of accuracy. We demonstrate the usefulness of this methodmore » with large-scale scanning transmission electron microscopy image simulations of a crystalline nanoparticle on an amorphous carbon substrate.« less
MDCT for computerized volumetry of pneumothoraces in pediatric patients.
Cai, Wenli; Lee, Edward Y; Vij, Abhinav; Mahmood, Soran A; Yoshida, Hiroyuki
2011-03-01
Our purpose in this study was to develop an automated computer-aided volumetry (CAV) scheme for quantifying pneumothorax in multidetector computed tomography (MDCT) images for pediatric patients and to investigate the imaging parameters that may affect its accuracy. Fifty-eight consecutive pediatric patients (mean age 12 ± 6 years) with pneumothorax who underwent MDCT for evaluation were collected retrospectively for this study. All cases were imaged by a 16- or 64-MDCT scanner with weight-based kilovoltage, low-dose tube current, 1.0-1.5 pitch, 0.6-5.0 mm slice thickness, and a B70f (sharp) or B31f (soft) reconstruction kernel. Sixty-three pneumothoraces ≥1 mL were visually identified in the left (n = 30) and right (n = 33) lungs. Each identified pneumothorax was contoured manually on an Amira workstation V4.1.1 (Mercury Computer Systems, Chelmsford, MA) by two radiologists in consensus. The computerized volumes of the pneumothoraces were determined by application of our CAV scheme. The accuracy of our automated CAV scheme was evaluated by comparison between computerized volumetry and manual volumetry, for the total volume of pneumothoraces in the left and right lungs. The mean difference between the computerized volumetry and the manual volumetry for all 63 pneumothoraces ≥1 mL was 8.2%. For pneumothoraces ≥10 mL, ≥50 mL, and ≥200 mL, the mean differences were 7.7% (n = 57), 7.3% (n = 33), and 6.4% (n = 13), respectively. The correlation coefficient was 0.99 between the computerized volume and the manual volume of pneumothoraces. Bland-Altman analysis showed that computerized volumetry has a mean difference of -5.1% compared to manual volumetry. For all pneumothoraces ≥10 mL, the mean differences for slice thickness ≤1.25 mm, = 1.5 mm, and = 5.0 mm were 6.1% (n = 28), 3.5% (n = 10), and 12.2% (n = 19), respectively. For the two reconstruction kernels, B70f and B31f, the mean differences were 6.3% (n = 42, B70f) and 11.7% (n = 15, B31f), respectively. Our automated CAV scheme provides an accurate measurement of pneumothorax volume in MDCT images of pediatric patients. For accurate volumetric quantification of pneumothorax in children in MDCT images by use of the automated CAV scheme, we recommended reconstruction parameters based on a slice thickness ≤1.5 mm and the reconstruction kernel B70f. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.
First Branchial Cleft Malformation with Duplication of External Auditory Canal
Parida, Pradipta Kumar; Raja, Kalairasi; Surianarayanan, Gopalakrishnan; Ganeshan, Sivaraman
2013-01-01
First branchial cleft anomalies are uncommon, accounting for less than 10% of all branchial abnormalities. Their rare occurrence and varied presentation have frequently led to misdiagnosis and inadequate and inappropriate treatment of these conditions leading to repeated recurrences and secondary infection. In this paper, a case of 11-year girl with type 2 first branchial cleft defect is described. She first presented with a nonhealing ulcer of upper neck from childhood. Diagnosis had previously been missed and treated as tubercular ulcer. We confirmed the correct diagnosis by history and computerized tomography fistulogram. The lesion was completely excised with no further recurrence. PMID:24312740
Thyroid tuberculosis: presenting symptom of mediastinal tuberculous lymphadenitis--an unusual case.
Chandanwale, Shirish S; Buch, Archana C; Vimal, Shruti S; Sachdeva, Punita
2014-01-01
Tuberculosis of thyroid gland is extremely rare. It spreads to thyroid by lymphogenous or heamatogenous route or from adjacent focus, either from larynx or cervical and mediastinal adenitis. We report an unusual case of a 33-year-old male with thyroid swelling. Fine needle aspiration (FNA) smears showed epithelioid cells without necrosis and acid fast bacilli (AFB). Subsequent investigation revealed mediastinal tuberculous lymphadenitis on Computerized Tomography (CT) scan. FNA confirmed the diagnosis of mediastinal tuberculous lymphadenitis. We conclude, when epithelioid cells are seen on FNA thyroid, tuberculosis must be ruled out especially in regions where there is high prevalence of tuberculosis.
[Bronchogenic esophageal cysts in the adult. Four cases].
Fékété, F; Rongère, C; Foulon, J P; Molas, G
1988-05-07
Bronchogenic oesophageal cysts possess a mucosa of the airway type but are unconnected to the tracheobronchial tree; they are in close anatomical relation with the oesophageal wall. These characteristics are explained by the fact that the respiratory and digestive tract share the same embryonic development. Four cases of bronchogenic oesophageal cyst are reported, and 21 well-documented cases from the literature are reviewed. The lesion is extremely rare in adults, often complicated and responsible for gastrointestinal, respiratory and sometimes even cardiac symptoms. Its features at radiology, endoscopy and computerized tomography are suggestive of the diagnosis. Treatment consists of excision by enucleation. Excision must be complete for recurrences to be avoided.
An Unusual Reason for Gastric Variceal Hemorrhage: Wandering Spleen.
Köseoğlu, Hüseyin; Atalay, Roni; Büyükaşık, Naciye Şemnur; Canyiğit, Murat; Özer, Mehmet; Solakoğlu, Tevfik; Akın, Fatma Ebru; Bolat, Aylin Demirezer; Yürekli, Öykü Tayfur; Ersoy, Osman
2015-12-01
Wandering spleen is the displacement of the spleen due to the loss or weakening of the ligaments of the spleen and is seen very rarely with an incidence of less than 0.5 %. It can cause portal hypertension, but gastric variceal hemorrhage is a quite rare condition within the spectrum of this uncommon disease. We report a 22-year-old woman with wandering spleen presenting with life-threatening gastric variceal hemorrhage. Her diagnosis was made by computerized tomography. Endoscopic therapy was not adequate to stop the bleeding, and urgent splenectomy was performed. After surgery she has been well with no symptoms until now.
Acoustic beam control in biomimetic projector via velocity gradient
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Xiaowei; Dong, Erqian; Song, Zhongchang
A biomimetic projector (BioP) based on computerized tomography of pygmy sperm whale's biosonar system has been designed using gradient-index (GRIN) material. The directivity of this BioP device was investigated as function of frequency and the velocity gradient of the GRIN material. A strong beam control over a broad bandwidth at the subwavelength scale has been achieved. Compared with a bare subwavelength source, the main lobe pressure of the BioP is about five times as high and the angular resolution is one order of magnitude better. Our results indicate that this BioP has excellent application potential in miniaturized underwater sonars.
Acoustic beam control in biomimetic projector via velocity gradient
NASA Astrophysics Data System (ADS)
Gao, Xiaowei; Zhang, Yu; Cao, Wenwu; Dong, Erqian; Song, Zhongchang; Li, Songhai; Tang, Liguo; Zhang, Sai
2016-07-01
A biomimetic projector (BioP) based on computerized tomography of pygmy sperm whale's biosonar system has been designed using gradient-index (GRIN) material. The directivity of this BioP device was investigated as function of frequency and the velocity gradient of the GRIN material. A strong beam control over a broad bandwidth at the subwavelength scale has been achieved. Compared with a bare subwavelength source, the main lobe pressure of the BioP is about five times as high and the angular resolution is one order of magnitude better. Our results indicate that this BioP has excellent application potential in miniaturized underwater sonars.
Significance of postshunt ventricular asymmetries.
Linder, M; Diehl, J T; Sklar, F H
1981-08-01
Ventricular asymmetries after shunt surgery were studied. Right and left ventricular areas from pre-and postoperative computerized tomography scans were measured with a computer digitizing technique, and the respective areas were expressed as a ratio. Measurements were made from the scans of 15 hydrocephalic children selected at random. Ages at surgery ranged from 1 to 101 weeks. The results indicate a significantly greater decrease in ventricular size on the side of the ventricular shunt catheter. Multiple regression analysis showed no relationship between the magnitude of change in ventricular size and either the patients' age orn the time intervals between surgery and follow-up scans. Possible mechanisms for these postshunt ventricular asymmetries are discussed.
Secondary signet-ring cell adenocarcinoma of urinary bladder from a gastric primary
Sharma, Pramod K.; Vijay, Mukesh K.; Das, Ranjit K.; Chatterjee, Uttara
2011-01-01
Primary bladder tumor is a frequent urological malignancy, whereas the incidence of secondary bladder tumor from a distant organ is quite rare. Secondary bladder neoplasms represent 1% of all malignant bladder tumors, of which distant metastases from stomach account for about 4% of cases. We present the case of a 30-year-old male who underwent partial gastrectomy for Signet-ring cell carcinoma of the stomach and presented 2 years later with hematuria. On computerized tomography scan, a bladder tumor was found which was resected cystoscopically. The histopathological examination revealed secondary Signet-ring cell adenocarcinoma of the urinary bladder. PMID:21747602
Endodontic management of a mandibular first molar with six root canal systems.
Jain, Dilip; Reddy, Smitha; Venigalla, Bhuvan Shome; Kamishetty, Shekhar
2015-01-01
Internal anatomy of pulp is complex. The first mandibular molars typically have two roots, one mesial with two root canals and another distal root, which contains one or two canals. A 20-year-old female patient reported with intermittent pain and incomplete root canal treatment in left lower back region since 1-week. Refined access cavity revealed initially two canals in mesial and two canals in the distal root. With operating microscope and cone beam computerized tomography, two additional canals (L-mesio-buccal and B-mesio-lingual) were identified in mesial root. One-year follow-up showed patient was asymptomatic and complete healing of periapical radiolucency.
[Imaging of temporo-mandibular disorders].
Felizardo, Rufino; Foucart, Jean-Michel; Pizelle, Christophe
2012-03-01
Dominated for years by standard films (tomographic mouth open and mouth closed X-rays, MRI) radiographs of the TMJ have progressively lost their usefulness to diagnosticians who have progressively increased their reliance on well codified clinical examinations, which suffice in a great majority of cases.The indications for and diagnostic worth of radiological studies and the impact they have on the management of TMJ disorders are today quite low especially when the high cost of procedures like MRI, computerized tomography, and CBCT is taken into account. In this article we discuss the various maladies that dentists might encounter and the situations in which radiological examinations are still indicated. © EDP Sciences, SFODF, 2012.
Cerebral edema, mass effects, and regional blood volume in man.
Penn, R D; Kurtz, D
1977-03-01
The authors conducted quantitative analysis of computerized tomography (CT) scans to measure tumor size, cerebral edema, and regional blood volume in man. Mass lesions without edema caused a local reduction in blood volume. Cerebral edema also reduced blood volume in proportion to its severity. Consideration of the electrolyte changes and water shifts in white-matter edema suggested that the decrease in absorption coefficient seen in CT scans was due to the increase in water content. Thus, in cerebral edema separation of blood vessels as well as increased interstitial pressure decrease blood volume, and the regional differences in turn reflect pressure gradients within the brain.
Gulati, Mittul; Dermendjian, Harout; Gómez, Ana M; Tan, Nelly; Margolis, Daniel J; Lu, David S; Gritsch, H Albin; Raman, Steven S
2016-01-01
Most living related donor (LRD) kidneys are harvested laparoscopically. Renal vascular anatomy helps determine donor suitability for laparoscopic nephrectomy. Computed tomography angiography (CTA) is the current gold standard for preoperative imaging; magnetic resonance angiography (MRA) offers advantages including lack of ionizing radiation and lower incidence of contrast reactions. We evaluated 3.0T MRA for assessing renal anatomy of LRDs. Thirty consecutive LRDs underwent CTA followed by 3.0T MRA. Data points included number and branching of vessels, incidental findings, and urothelial opacification. Studies were individually evaluated by three readers blinded to patient data. Studies were reevaluated in consensus with discrepancies revealed, and final consensus results were labeled "truth". Compared with consensus "truth", both computed tomography (CT) and magnetic resonance imaging were highly accurate for assessment of arterial and venous anatomy, although CT was superior for detection of late venous confluence as well as detection of renal stones. Both modalities were comparable in opacification of lower ureters and bladder; MRA underperformed CTA for opacification of upper urinary tracts. 3.0T MRA enabled excellent detection of comprehensive renal anatomy compared to CTA in LRDs. Copyright © 2016 Elsevier Inc. All rights reserved.
Cooper, W C
1985-01-01
The various congenital and acquired conditions which alter orbital volume are reviewed. Previous investigative work to determine orbital capacity is summarized. Since these studies were confined to postmortem evaluations, the need for a technique to measure orbital volume in the living state is presented. A method for volume determination of the orbit and its contents by high-resolution axial tomography and quantitative digital image analysis is reported. This procedure has proven to be accurate (the discrepancy between direct and computed measurements ranged from 0.2% to 4%) and reproducible (greater than 98%). The application of this method to representative clinical problems is presented and discussed. The establishment of a diagnostic system versatile enough to expand the usefulness of computerized axial tomography and polytomography should add a new dimension to ophthalmic investigation and treatment. Images FIGURE 8 FIGURE 9 FIGURE 10 A FIGURE 10 B FIGURE 11 A FIGURE 11 B FIGURE 12 FIGURE 13 FIGURE 14 FIGURE 15 FIGURE 16 FIGURE 17 FIGURE 18 FIGURE 19 FIGURE 20 FIGURE 21 FIGURE 22 FIGURE 23 FIGURE 24 FIGURE 25 FIGURE 26 A FIGURE 26 B FIGURE 27 FIGURE 28 FIGURE 29 FIGURE 30 FIGURE 31 FIGURE 32 PMID:3938582
NASA Astrophysics Data System (ADS)
Cushley, Alex Clay
The proposed launch of a CubeSat carrying the first space-borne ADS-B receiver by RMCC will create a unique opportunity to study the modification of radio waves following propagation through the ionosphere as the signals propagate from the transmitting aircraft to the passive satellite receiver(s). Experimental work is described which successfully demonstrated that ADS-B data can be used to reconstruct two-dimensional electron density maps of the ionosphere using techniques from computerized tomography. Ray-tracing techniques are used to determine the characteristics of individual waves, including the wave path and the state of polarization at the satellite receiver. The modelled Faraday rotation is determined and converted to TEC along the ray-paths. The resulting TEC is used as input for CIT using ART. This study concentrated on meso-scale structures 100--1000 km in horizontal extent. The primary scientific interest of this thesis was to show the feasibility of a new method to image the ionosphere and obtain a better understanding of magneto-ionic wave propagation. Keywords: Automatic Dependent Surveillance-Broadcast (ADS-B), Faraday rotation, electromagnetic (EM) waves, radio frequency (RF) propagation, ionosphere (auroral, irregularities, instruments and techniques), electron density profile, total electron content (TEC), computer ionospheric tomography (CIT), algebraic reconstruction technique (ART).
NASA Astrophysics Data System (ADS)
Staton, Robert J.; Lee, Choonik; Lee, Choonsik; Williams, Matt D.; Hintenlang, David E.; Arreola, Manuel M.; Williams, Jonathon L.; Bolch, Wesley E.
2006-10-01
In this study, two computational phantoms of the newborn patient were used to assess individual organ doses and effective doses delivered during head, chest, abdomen, pelvis, and torso examinations using the Siemens SOMATOM Sensation 16 helical multi-slice computed tomography (MSCT) scanner. The stylized phantom used to model the patient anatomy was the revised ORNL newborn phantom by Han et al (2006 Health Phys.90 337). The tomographic phantom used in the study was that developed by Nipper et al (2002 Phys. Med. Biol. 47 3143) as recently revised by Staton et al (2006 Med. Phys. 33 3283). The stylized model was implemented within the MCNP5 radiation transport code, while the tomographic phantom was incorporated within the EGSnrc code. In both codes, the x-ray source was modelled as a fan beam originating from the focal spot at a fan angle of 52° and a focal-spot-to-axis distance of 57 cm. The helical path of the source was explicitly modelled based on variations in collimator setting (12 mm or 24 mm), detector pitch and scan length. Tube potentials of 80, 100 and 120 kVp were considered in this study. Beam profile data were acquired using radiological film measurements on a 16 cm PMMA phantom, which yielded effective beam widths of 14.7 mm and 26.8 mm for collimator settings of 12 mm and 24 mm, respectively. Values of absolute organ absorbed dose were determined via the use of normalization factors defined as the ratio of the CTDI100 measured in-phantom and that determined by Monte Carlo simulation of the PMMA phantom and ion chamber. Across various technique factors, effective dose differences between the stylized and tomographic phantoms ranged from +2% to +9% for head exams, -4% to -2% for chest exams, +8% to +24% for abdominal exams, -16% to -12% for pelvic exams and -7% to 0% for chest-abdomen-pelvis (CAP) exams. In many cases, however, relatively close agreement in effective dose was accomplished at the expense of compensating errors in individual organ dose. Per cent differences in organ dose between the stylized and tomographic phantoms at 120 kVp and 12 mm collimator setting ranged from -25% (skin) to +164% (muscle) for head exams, -92% (thyroid) to +98% (ovaries) for chest exams, -144% (uterus) to +112% (ovaries) for abdominal exams, -98% (SI wall) to +20% (thymus) for pelvic exams and -60% (extrathoracic airways) to +13% (ovaries) for CAP exams. Better agreement was seen between the two phantom types for organs entirely within the scan field. In these cases, corresponding per cent differences in organ absorbed dose did not vary more than 17%. For all scans, the effective dose was found to range approximately 1-13 mSv across the scan parameters and scan regions. The largest effective dose occurred for CAP scans at 120 kVp.
Kühl, J Tobias; Lønborg, Jacob; Fuchs, Andreas; Andersen, Mads J; Vejlstrup, Niels; Kelbæk, Henning; Engstrøm, Thomas; Møller, Jacob E; Kofoed, Klaus F
2012-06-01
Measurement of left atrial (LA) maximal volume (LA(max)) using two-dimensional transthoracic echocardiography (TTE) provides prognostic information in several cardiac diseases. However, the relationship between LA(max) and LA function is poorly understood and TTE is less well suited for measuring dynamic LA volume changes. Conversely, cardiac magnetic resonance imaging (CMR) and multi-slice computed tomography (MSCT) appears more appropriate for such measures. We sought to determine the relationship between LA size assessed with TTE and LA size and function assessed with CMR and MSCT. Fifty-four patients were examined 3 months post myocardial infarction with echocardiography, CMR and MSCT. Left atrial volumes and LA reservoir function were assessed by TTE. LA time-volume curves were determined and LA reservoir function (cyclic change and fractional change), passive emptying function (reservoir volume) and pump function (left atrial ejection fraction-LAEF) were derived using CMR and MSCT. Left atrial fractional change and left atrial ejection fraction (LAEF) determined with CMR and MSCT were unrelated to LA(max) enlargement by echocardiography (P = NS). There was an overall good agreement between CMR and MSCT, with a small to moderate bias in LA(max) (4.9 ± 10.4 ml), CC (3.1 ± 9.1 ml) and reservoir volume (3.4 ± 9.1 ml). TTE underestimates LA(max) with up to 32% compared with CMR and MSCT (P < 0.001). Left atrial function assessed with MSCT and CMR as LA fractional change and LAEF is not significantly related to LA(max) measured by TTE. TTE systematically underestimated LA volumes, whereas there are good agreements between MSCT and CMR for volumetric and functional properties.
Investigating different computed tomography techniques for internal target volume definition.
Yoganathan, S A; Maria Das, K J; Subramanian, V Siva; Raj, D Gowtham; Agarwal, Arpita; Kumar, Shaleen
2017-01-01
The aim of this work was to evaluate the various computed tomography (CT) techniques such as fast CT, slow CT, breath-hold (BH) CT, full-fan cone beam CT (FF-CBCT), half-fan CBCT (HF-CBCT), and average CT for delineation of internal target volume (ITV). In addition, these ITVs were compared against four-dimensional CT (4DCT) ITVs. Three-dimensional target motion was simulated using dynamic thorax phantom with target insert of diameter 3 cm for ten respiration data. CT images were acquired using a commercially available multislice CT scanner, and the CBCT images were acquired using On-Board-Imager. Average CT was generated by averaging 10 phases of 4DCT. ITVs were delineated for each CT by contouring the volume of the target ball; 4DCT ITVs were generated by merging all 10 phases target volumes. Incase of BH-CT, ITV was derived by boolean of CT phases 0%, 50%, and fast CT target volumes. ITVs determined by all CT and CBCT scans were significantly smaller (P < 0.05) than the 4DCT ITV, whereas there was no significant difference between average CT and 4DCT ITVs (P = 0.17). Fast CT had the maximum deviation (-46.1% ± 20.9%) followed by slow CT (-34.3% ± 11.0%) and FF-CBCT scans (-26.3% ± 8.7%). However, HF-CBCT scans (-12.9% ± 4.4%) and BH-CT scans (-11.1% ± 8.5%) resulted in almost similar deviation. On the contrary, average CT had the least deviation (-4.7% ± 9.8%). When comparing with 4DCT, all the CT techniques underestimated ITV. In the absence of 4DCT, the HF-CBCT target volumes with appropriate margin may be a reasonable approach for defining the ITV.
Detection of crestal radiolucencies around dental implants: an in vitro experimental study.
Sirin, Yigit; Horasan, Sinan; Yaman, Duygu; Basegmez, Cansu; Tanyel, Cem; Aral, Ali; Guven, Koray
2012-07-01
The aim of this study was to compare the diagnostic potentials and practical advantages of different imaging modalities in detecting bone defects around dental implants. Crestal bone defects with sequentially larger diameters were randomly prepared around 100 implants that were inserted in bovine bone blocks. Conventional periapical radiography (PR), direct digital radiography (DDR), panoramic radiography (PANO), cone-beam computed tomography (CBCT), and multislice computed tomography (MSCT) were performed for all specimens. The diagnostic accuracies of the devices, confidence of the answers, subjective image quality, defect visibility in planar orientations, and duration of diagnosis were analyzed based on the interpretations of 7 calibrated observers. The agreement levels of intra- and interobserver scores were rated good. PR, DDR, and CBCT were mostly more accurate than PANO and MSCT (P < .05). Confidence levels were positively correlated with the defect size (ρ = 0.20, P < .01), and that of DDR was the highest (P < .05). The subjective image quality of PR and DDR was higher than that of CBCT, PANO, and MSCT (P < .05 for all comparisons). Axial-coronal-sagittal visibilities of the defects were higher for CBCT compared with MSCT (P < .05). The diagnostic time was shorter for DDR (P < .05) and longer for the tomographic systems (P < .05) than for the other devices. DDR may provide a faster and more confident diagnostic option that is as accurate as PR in detecting peri-implant radiolucencies. CBCT has a comparable potential to these intraoral systems but with slower decision making and lower image quality, whereas PANO and MSCT become more reliable when bone defects have a diameter that is at least 1.5 mm larger than that of the implant. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Wobser, Hella; Wiest, Reiner; Salzberger, Bernd; Wohlgemuth, Walter Alexander; Stroszczynski, Christian; Jung, Ernst-Michael
2014-01-01
To evaluate treatment response of hepatocellular carcinoma (HCC) after transarterial chemoembolization (TACE) with a new real-time imaging fusion technique of contrast-enhanced ultrasound (CEUS) with multi-slice detection computed tomography (CT) in comparison to conventional post-interventional follow-up. 40 patients with HCC (26 male, ages 46-81 years) were evaluated 24 hours after TACE using CEUS with ultrasound volume navigation and image fusion with CT compared to non-enhanced CT and follow-up contrast-enhanced CT after 6-8 weeks. Reduction of tumor vascularization to less than 25% was regarded as "successful" treatment, whereas reduction to levels >25% was considered as "partial" treatment response. Homogenous lipiodol retention was regarded as successful treatment in non-enhanced CT. Post-interventional image fusion of CEUS with CT was feasible in all 40 patients. In 24 patients (24/40), post-interventional image fusion with CEUS revealed residual tumor vascularity, that was confirmed by contrast-enhanced CT 6-8 weeks later in 24/24 patients. In 16 patients (16/40), post-interventional image fusion with CEUS demonstrated successful treatment, but follow-up CT detected residual viable tumor (6/16). Non-enhanced CT did not identify any case of treatment failure. Image fusion with CEUS assessed treatment efficacy with a specificity of 100%, sensitivity of 80% and a positive predictive value of 1 (negative predictive value 0.63). Image fusion of CEUS with CT allows a reliable, highly specific post-interventional evaluation of embolization response with good sensitivity without any further radiation exposure. It can detect residual viable tumor at early state, resulting in a close patient monitoring or re-therapy.
SPECT/CT imaging in general orthopedic practice.
Scharf, Stephen
2009-09-01
The availability of hybrid devices that combine the latest single-photon emission computed tomography (SPECT) imaging technology with multislice computed tomography (CT) scanning has allowed us to detect subtle, nonspecific abnormalities on bone scans and interpret them as specific focal areas of pathology. Abnormalities in the spine can be separated into those caused by pars fractures, facet joint arthritis, or osteophyte formation on vertebral bodies. Compression fractures can be distinguished from severe degenerative disease, both of which can cause intense activity across the spine on either planar or SPECT imaging. Localizing activity in patients who have had spinal fusion can provide tremendous insight into the causes of therapeutic failures. Infections of the spine now can be diagnosed with gallium SPECT/CT, despite the fact that gallium has long been abandoned because of its failure to detect spine infection on either planar or SPECT imaging. Small focal abnormalities in the feet and ankles can be localized well enough to make specific orthopedic diagnoses on the basis of their location. Moreover, when radiographic imaging provides equivocal or inadequate information, SPECT/CT can provide a road map for further diagnostic studies and has been invaluable in planning surgery. Our ability to localize activity within a bone or at an articular surface has allowed us to distinguish between fractures and joint disease. Increased activity associated with congenital anomalies, such as tarsal coalition and Bertolotti's syndrome have allowed us to understand the pathophysiology of these conditions, to confirm them as the cause of the patient's symptoms, and to provide information that is useful in determining appropriate clinical management. As our experience broadens, SPECT/CT will undoubtedly become an important tool in the evaluation and management of a wider variety of orthopedic patients.
Jöres, A P W; Heverhagen, J T; Bonél, H; Exadaktylos, A; Klink, T
2016-02-01
The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. The overall sensitivity of LS was 49.2 %, the specificity was 93.3 %, the positive predictive value was 91 %, and the negative predictive value was 57.5 %. The overall sensitivity for vertebral fractures was 16.7 %, and the specificity was 100 %. The sensitivity was 48.7 % and the specificity 98.2 % for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS. 40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT. The overall sensitivity of LS for truncal skeleton injuries in multiple-trauma patients was < 50 %. The diagnostic reference standard MSCT is the preferred and reliable imaging modality. LS may be valuable for quick detection of extremity fractures. © Georg Thieme Verlag KG Stuttgart · New York.
Zachenhofer, Iris; Cejna, Manfred; Schuster, Antonius; Donat, Markus; Roessler, Karl
2010-06-01
Computed tomography angiography (CTA) is a time and cost saving investigation for postoperative evaluation of clipped cerebral aneurysm patients. A retrospective study was conducted to analyse image quality and artefact generation due to implanted aneurysm clips using a new technology. MSCTA was performed pre- and postoperatively using a Philips Brilliance 64-detector-row CT scanner. Altogether, 32 clipping sites were analysed in 27 patients (11 female and 16 male, mean ages 52a, from 24 to 72 years). Clip number per aneurysm was 2.3 mean (from 1 to 4), 54 clips were made of titanium alloy and 5 of cobalt alloy. Altogether, image quality was rated 1.8 mean, using a scale from 1 (very good) to 5 (unserviceable) and clip artefacts were rated 2.4 mean, using a 5 point rating scale (1 no artefacts, 5 unserviceable due to artefacts). A significant loss of image quality and rise of artefacts was found when using cobalt alloy clips (1.4 versus 4.2 and 2.1 versus 4.0). In 72% of all investigations, an excellent image quality was found. Excluding the cobalt clip group, 85% of scans showed excellent image quality. Artefacts were absent or minimal (grade 1 or 2) in 69% of all investigations and in 81% in the pure titanium clip group. In 64-row MSCTA of good image quality with low artefacts, it was possible to detect small aneurysm remnants of 2mm size in individual patients. By using titanium alloy clips, in our study up to 85% of postoperative CTA images were of excellent quality with absent or minimal artefacts in 81% and seem adequate to detect small aneurysm remnants. Copyright 2010 Elsevier B.V. All rights reserved.
Hippeläinen, Eero; Mäkelä, Teemu; Kaasalainen, Touko; Kaleva, Erna
2017-12-01
Developments in single photon emission tomography instrumentation and reconstruction methods present a potential for decreasing acquisition times. One of such recent options for myocardial perfusion imaging (MPI) is IQ-SPECT. This study was motivated by the inconsistency in the reported ejection fraction (EF) and left ventricular (LV) volume results between IQ-SPECT and more conventional low-energy high-resolution (LEHR) collimation protocols. IQ-SPECT and LEHR quantitative results were compared while the equivalent number of iterations (EI) was varied. The end-diastolic (EDV) and end-systolic volumes (ESV) and the derived EF values were investigated. A dynamic heart phantom was used to produce repeatable ESVs, EDVs and EFs. Phantom performance was verified by comparing the set EF values to those measured from a gated multi-slice X-ray computed tomography (CT) scan (EF True ). The phantom with an EF setting of 45, 55, 65 and 70% was imaged with both IQ-SPECT and LEHR protocols. The data were reconstructed with different EI, and two commonly used clinical myocardium delineation software were used to evaluate the LV volumes. The CT verification showed that the phantom EF settings were repeatable and accurate with the EF True being within 1% point from the manufacture's nominal value. Depending on EI both MPI protocols can be made to produce correct EF estimates, but IQ-SPECT protocol produced on average 41 and 42% smaller EDV and ESV when compared to the phantom's volumes, while LEHR protocol underestimated volumes by 24 and 21%, respectively. The volume results were largely similar between the delineation methods used. The reconstruction parameters can greatly affect the volume estimates obtained from perfusion studies. IQ-SPECT produces systematically smaller LV volumes than the conventional LEHR MPI protocol. The volume estimates are also software dependent.
Yu, Tong; Gao, Jun; Liu, Zhi-Min; Zhang, Qi-Feng; Liu, Yong; Jiang, Ling; Peng, Yun
2017-01-01
Background: Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors. Methods: Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled. The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast, and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode. Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A. In addition, filtered back-projection (FBP) reconstruction was used for monochromatic images <60 keV in Group A. The total radiation dose, total iodine load, contrast injection speed, and maximum injection pressure were compared between the two groups. The 40 keV and 60 keV spectral CT images of Group A were compared with the images of Group B to evaluate overall image quality. Results: The total radiation dose, total iodine load, injection speed, and maximum injection pressure for Group A were decreased by 19%, 15%, 34.4%, and 18.3%, respectively. The optimal energy level in spectral CT for displaying the abdominal vessels was 40 keV. At this level, the CT values in the abdominal aorta and its three branches, the portal vein and its two branches, and the inferior vena cava were all greater than 340 hounsfield unit (HU). The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t = 0.36 and −1.716 for liver, −0.153 and −1.546 for pancreas, and 2.427 and 0.866 for renal cortex, all P > 0.05). Signal-to-noise ratio of the abdominal organs was significantly lower in Group A than in Group B (t = −8.11 for liver, −7.83 for pancreas, and −5.38 for renal cortex, all P < 0.05). However, the subjective scores for the 40 keV (FBP) and 60 keV (40% ASiR) spectral CT images determined by two radiologists were all >3, indicating clinically acceptable image quality. Conclusions: Single-phase, dual-energy spectral CT used for children with solid abdominal tumors can reduce contrast dose and radiation dose and can also maintain clinically acceptable image quality. PMID:28345547
Yu, Tong; Gao, Jun; Liu, Zhi-Min; Zhang, Qi-Feng; Liu, Yong; Jiang, Ling; Peng, Yun
2017-04-05
Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors. Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled. The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast, and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode. Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A. In addition, filtered back-projection (FBP) reconstruction was used for monochromatic images <60 keV in Group A. The total radiation dose, total iodine load, contrast injection speed, and maximum injection pressure were compared between the two groups. The 40 keV and 60 keV spectral CT images of Group A were compared with the images of Group B to evaluate overall image quality. The total radiation dose, total iodine load, injection speed, and maximum injection pressure for Group A were decreased by 19%, 15%, 34.4%, and 18.3%, respectively. The optimal energy level in spectral CT for displaying the abdominal vessels was 40 keV. At this level, the CT values in the abdominal aorta and its three branches, the portal vein and its two branches, and the inferior vena cava were all greater than 340 hounsfield unit (HU). The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t = 0.36 and -1.716 for liver, -0.153 and -1.546 for pancreas, and 2.427 and 0.866 for renal cortex, all P> 0.05). Signal-to-noise ratio of the abdominal organs was significantly lower in Group A than in Group B (t = -8.11 for liver, -7.83 for pancreas, and -5.38 for renal cortex, all P< 0.05). However, the subjective scores for the 40 keV (FBP) and 60 keV (40% ASiR) spectral CT images determined by two radiologists were all> 3, indicating clinically acceptable image quality. Single-phase, dual-energy spectral CT used for children with solid abdominal tumors can reduce contrast dose and radiation dose and can also maintain clinically acceptable image quality.
Dynamic multi-coil tailored excitation for transmit B1 correction at 7 Tesla.
Umesh Rudrapatna, S; Juchem, Christoph; Nixon, Terence W; de Graaf, Robin A
2016-07-01
Tailored excitation (TEx) based on interspersing multiple radio frequency pulses with linear gradient and higher-order shim pulses can be used to obtain uniform flip angle in the presence of large radio frequency transmission (B 1+) inhomogeneity. Here, an implementation of dynamic, multislice tailored excitation using the recently developed multi-coil nonlinear shim hardware (MC-DTEx) is reported. MC-DTEx was developed and tested both in a phantom and in vivo at 7 T, and its efficacy was quantitatively assessed. Predicted outcomes of MC-DTEx and DTEx based on spherical harmonic shims (SH-DTEx) were also compared. For a planned 30 ° flip angle, in a phantom, the standard deviation in excitation improved from 28% (regular excitation) to 12% with MC-DTEx. The SD in in vivo excitation improved from 22 to 12%. The improvements achieved with experimental MC-DTEx closely matched the theoretical predictions. Simulations further showed that MC-DTEx outperforms SH-DTEx for both scenarios. Successful implementation of multislice MC-DTEx is presented and is shown to be capable of homogenizing excitation over more than twofold B 1+ variations. Its benefits over SH-DTEx are also demonstrated. A distinct advantage of MC hardware over SH shim hardware is the absence of significant eddy current effects, which allows for a straightforward, multislice implementation of MC-DTEx. Magn Reson Med 76:83-93, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Jiang, Kai; Li, Wen; Li, Wei; Jiao, Sen; Castel, Laurie; Van Wagoner, David R; Yu, Xin
2015-11-01
The aim of this study was to develop a rapid, multislice cardiac T1 mapping method in mice and to apply the method to quantify manganese (Mn(2+)) uptake in a mouse model with altered Ca(2+) channel activity. An electrocardiography-triggered multislice saturation-recovery Look-Locker method was developed and validated both in vitro and in vivo. A two-dose study was performed to investigate the kinetics of T1 shortening, Mn(2+) relaxivity in myocardium, and the impact of Mn(2+) on cardiac function. The sensitivity of Mn(2+)-enhanced MRI in detecting subtle changes in altered Ca(2+) channel activity was evaluated in a mouse model with α-dystrobrevin knockout. Validation studies showed strong agreement between the current method and an established method. High Mn(2+) dose led to significantly accelerated T1 shortening. Heart rate decreased during Mn(2+) infusion, while ejection ratio increased slightly at the end of imaging protocol. No statistical difference in cardiac function was detected between the two dose groups. Mice with α-dystrobrevin knockout showed enhanced Mn(2+) uptake in vivo. In vitro patch-clamp study showed increased Ca(2+) channel activity. The saturation recovery method provides rapid T1 mapping in mouse hearts, which allowed sensitive detection of subtle changes in Mn(2+) uptake in α-dystrobrevin knockout mice. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
McClelland, Jamie R.; Modat, Marc; Arridge, Simon; Grimes, Helen; D'Souza, Derek; Thomas, David; O' Connell, Dylan; Low, Daniel A.; Kaza, Evangelia; Collins, David J.; Leach, Martin O.; Hawkes, David J.
2017-06-01
Surrogate-driven respiratory motion models relate the motion of the internal anatomy to easily acquired respiratory surrogate signals, such as the motion of the skin surface. They are usually built by first using image registration to determine the motion from a number of dynamic images, and then fitting a correspondence model relating the motion to the surrogate signals. In this paper we present a generalized framework that unifies the image registration and correspondence model fitting into a single optimization. This allows the use of ‘partial’ imaging data, such as individual slices, projections, or k-space data, where it would not be possible to determine the motion from an individual frame of data. Motion compensated image reconstruction can also be incorporated using an iterative approach, so that both the motion and a motion-free image can be estimated from the partial image data. The framework has been applied to real 4DCT, Cine CT, multi-slice CT, and multi-slice MR data, as well as simulated datasets from a computer phantom. This includes the use of a super-resolution reconstruction method for the multi-slice MR data. Good results were obtained for all datasets, including quantitative results for the 4DCT and phantom datasets where the ground truth motion was known or could be estimated.
McClelland, Jamie R; Modat, Marc; Arridge, Simon; Grimes, Helen; D'Souza, Derek; Thomas, David; Connell, Dylan O'; Low, Daniel A; Kaza, Evangelia; Collins, David J; Leach, Martin O; Hawkes, David J
2017-06-07
Surrogate-driven respiratory motion models relate the motion of the internal anatomy to easily acquired respiratory surrogate signals, such as the motion of the skin surface. They are usually built by first using image registration to determine the motion from a number of dynamic images, and then fitting a correspondence model relating the motion to the surrogate signals. In this paper we present a generalized framework that unifies the image registration and correspondence model fitting into a single optimization. This allows the use of 'partial' imaging data, such as individual slices, projections, or k-space data, where it would not be possible to determine the motion from an individual frame of data. Motion compensated image reconstruction can also be incorporated using an iterative approach, so that both the motion and a motion-free image can be estimated from the partial image data. The framework has been applied to real 4DCT, Cine CT, multi-slice CT, and multi-slice MR data, as well as simulated datasets from a computer phantom. This includes the use of a super-resolution reconstruction method for the multi-slice MR data. Good results were obtained for all datasets, including quantitative results for the 4DCT and phantom datasets where the ground truth motion was known or could be estimated.
McClelland, Jamie R; Modat, Marc; Arridge, Simon; Grimes, Helen; D’Souza, Derek; Thomas, David; Connell, Dylan O’; Low, Daniel A; Kaza, Evangelia; Collins, David J; Leach, Martin O; Hawkes, David J
2017-01-01
Abstract Surrogate-driven respiratory motion models relate the motion of the internal anatomy to easily acquired respiratory surrogate signals, such as the motion of the skin surface. They are usually built by first using image registration to determine the motion from a number of dynamic images, and then fitting a correspondence model relating the motion to the surrogate signals. In this paper we present a generalized framework that unifies the image registration and correspondence model fitting into a single optimization. This allows the use of ‘partial’ imaging data, such as individual slices, projections, or k-space data, where it would not be possible to determine the motion from an individual frame of data. Motion compensated image reconstruction can also be incorporated using an iterative approach, so that both the motion and a motion-free image can be estimated from the partial image data. The framework has been applied to real 4DCT, Cine CT, multi-slice CT, and multi-slice MR data, as well as simulated datasets from a computer phantom. This includes the use of a super-resolution reconstruction method for the multi-slice MR data. Good results were obtained for all datasets, including quantitative results for the 4DCT and phantom datasets where the ground truth motion was known or could be estimated. PMID:28195833
Software compensation of eddy current fields in multislice high order dynamic shimming.
Sengupta, Saikat; Avison, Malcolm J; Gore, John C; Brian Welch, E
2011-06-01
Dynamic B(0) shimming (DS) can produce better field homogeneity than static global shimming by dynamically updating slicewise shim values in a multislice acquisition. The performance of DS however is limited by eddy current fields produced by the switching of 2nd and 3rd order unshielded shims. In this work, we present a novel method of eddy field compensation (EFC) applied to higher order shim induced eddy current fields in multislice DS. This method does not require shim shielding, extra hardware for eddy current compensation or subject specific prescanning. The interactions between shim harmonics are modeled assuming steady state of the medium and long time constant, cross and self term eddy fields in a DS experiment and 'correction factors' characterizing the entire set of shim interactions are derived. The correction factors for a given time between shim switches are shown to be invariable with object scanned, shim switching pattern and actual shim values, allowing for their generalized prospective use. Phantom and human head, 2nd and 3rd order DS experiments performed without any hardware eddy current compensation using the technique show large reductions in field gradients and offsets leading to significant improvements in image quality. This method holds promise as an alternative to expensive hardware based eddy current compensation required in 2nd and 3rd order DS. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru
2007-03-01
Multislice CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multislice CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. Moreover, we have provided diagnostic assistance methods to medical screening specialists by using a lung cancer screening algorithm built into mobile helical CT scanner for the lung cancer mass screening done in the region without the hospital. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system.