Morizane, Yuki; Shiode, Yusuke; Hirano, Masayuki; Doi, Shinichiro; Toshima, Shinji; Fujiwara, Atsushi; Shiraga, Fumio
2017-01-01
Purpose To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). Methods A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. Results The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). Conclusion When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4–6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability. PMID:28863141
Kimura, Shuhei; Morizane, Yuki; Shiode, Yusuke; Hirano, Masayuki; Doi, Shinichiro; Toshima, Shinji; Fujiwara, Atsushi; Shiraga, Fumio
2017-01-01
To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4-6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability.
Peng, Jie; Zhang, Qi; Jin, Hai-Ying; Lu, Wu-Yi; Zhao, Pei-Quan
2016-01-01
To compare the results of non-mydriatic ultra-wide field imaging system, mydriatic slit-lamp lens (Volk +90 D) and mydriatic Goldmann three-mirror contact lens examinations in screening fundus lesions among patients after cataract surgery. Non-mydriatic images were obtained with an Optomap panoramic 200Tx (Optomap 200Tx) 3d after surgery and graded by a blinded ophthalmologist. A mydriatic slit-lamp lens examination was performed by another blinded retinal specialist on the same day. A third blinded retinal specialist examined patients two weeks after surgery using a Goldmann three-mirror contact lens. In total, 160 patients (184 eyes) were examined, and 66, 69, and 75 cases of retinal lesion(s) were identified using the Optomap 200Tx, slit-lamp lens, and Goldmann three-mirror contact lens, respectively. In 13 cases, fundus changes were sight-threatening. The results obtained by Optomap 200Tx examination and by mydriatic slit-lamp lens examination have good consistency (P=0.375, Kappa=0.942). The mydriatic Goldmann three-mirror lens examination revealed more fundus lesions but are consistent with Optomap 200Tx (P=0.004, Kappa=0.897) and mydriatic slit-lamp lens examination (P=0.031, Kappa=0.932). Early post-operative fundus screening in cataract patients is extremely important and necessary to prevent further vision loss. Wide-field imaging is a feasible and convenient tool for fundus examination that can be used as a primary screening method among patients after cataract surgery.
Modification of a Kowa RC-2 fundus camera for self-photography without the use of mydriatics.
Philpott, D E; Bailey, P F; Harrison, G; Turnbill, C
1979-01-01
Research on retinal circulation during space flight required the development of a simple technique to provide self monitoring of blood vessel changes in the fundus without the use of mydriatics. A Kowa RC-2 fundus camera was modified for self-photography by the use of a bite plate for positioning and cross hairs for focusing the subject's retina relative to the film plane. Dilation of the pupils without the use of mydriatics was accomplished by dark adaption of the subject. Pictures were obtained without pupil constriction by the use of a high speed strobe light. This method also has applications for clinical medicine.
NASA Technical Reports Server (NTRS)
Philpott, D. E.; Harrison, G.; Turnbill, C.; Bailey, P. F.
1979-01-01
Research on retinal circulation during space flight required the development of a simple technique to provide self monitoring of blood vessel changes in the fundus without the use of mydriatics. A Kowa RC-2 fundus camera was modified for self-photography by the use of a bite plate for positioning and cross hairs for focusing the subject's retina relative to the film plane. Dilation of the pupils without the use of mydriatics was accomplished by dark-adaption of the subject. Pictures were obtained without pupil constriction by the use of a high speed strobe light. This method also has applications for clinical medicine.
Bawankar, Pritam; Shanbhag, Nita; K., S. Smitha; Dhawan, Bodhraj; Palsule, Aratee; Kumar, Devesh; Chandel, Shailja
2017-01-01
Diabetic retinopathy (DR) is a leading cause of blindness among working-age adults. Early diagnosis through effective screening programs is likely to improve vision outcomes. The ETDRS seven-standard-field 35-mm stereoscopic color retinal imaging (ETDRS) of the dilated eye is elaborate and requires mydriasis, and is unsuitable for screening. We evaluated an image analysis application for the automated diagnosis of DR from non-mydriatic single-field images. Patients suffering from diabetes for at least 5 years were included if they were 18 years or older. Patients already diagnosed with DR were excluded. Physiologic mydriasis was achieved by placing the subjects in a dark room. Images were captured using a Bosch Mobile Eye Care fundus camera. The images were analyzed by the Retinal Imaging Bosch DR Algorithm for the diagnosis of DR. All subjects also subsequently underwent pharmacological mydriasis and ETDRS imaging. Non-mydriatic and mydriatic images were read by ophthalmologists. The ETDRS readings were used as the gold standard for calculating the sensitivity and specificity for the software. 564 consecutive subjects (1128 eyes) were recruited from six centers in India. Each subject was evaluated at a single outpatient visit. Forty-four of 1128 images (3.9%) could not be read by the algorithm, and were categorized as inconclusive. In four subjects, neither eye provided an acceptable image: these four subjects were excluded from the analysis. This left 560 subjects for analysis (1084 eyes). The algorithm correctly diagnosed 531 of 560 cases. The sensitivity, specificity, and positive and negative predictive values were 91%, 97%, 94%, and 95% respectively. The Bosch DR Algorithm shows favorable sensitivity and specificity in diagnosing DR from non-mydriatic images, and can greatly simplify screening for DR. This also has major implications for telemedicine in the use of screening for retinopathy in patients with diabetes mellitus. PMID:29281690
Bawankar, Pritam; Shanbhag, Nita; K, S Smitha; Dhawan, Bodhraj; Palsule, Aratee; Kumar, Devesh; Chandel, Shailja; Sood, Suneet
2017-01-01
Diabetic retinopathy (DR) is a leading cause of blindness among working-age adults. Early diagnosis through effective screening programs is likely to improve vision outcomes. The ETDRS seven-standard-field 35-mm stereoscopic color retinal imaging (ETDRS) of the dilated eye is elaborate and requires mydriasis, and is unsuitable for screening. We evaluated an image analysis application for the automated diagnosis of DR from non-mydriatic single-field images. Patients suffering from diabetes for at least 5 years were included if they were 18 years or older. Patients already diagnosed with DR were excluded. Physiologic mydriasis was achieved by placing the subjects in a dark room. Images were captured using a Bosch Mobile Eye Care fundus camera. The images were analyzed by the Retinal Imaging Bosch DR Algorithm for the diagnosis of DR. All subjects also subsequently underwent pharmacological mydriasis and ETDRS imaging. Non-mydriatic and mydriatic images were read by ophthalmologists. The ETDRS readings were used as the gold standard for calculating the sensitivity and specificity for the software. 564 consecutive subjects (1128 eyes) were recruited from six centers in India. Each subject was evaluated at a single outpatient visit. Forty-four of 1128 images (3.9%) could not be read by the algorithm, and were categorized as inconclusive. In four subjects, neither eye provided an acceptable image: these four subjects were excluded from the analysis. This left 560 subjects for analysis (1084 eyes). The algorithm correctly diagnosed 531 of 560 cases. The sensitivity, specificity, and positive and negative predictive values were 91%, 97%, 94%, and 95% respectively. The Bosch DR Algorithm shows favorable sensitivity and specificity in diagnosing DR from non-mydriatic images, and can greatly simplify screening for DR. This also has major implications for telemedicine in the use of screening for retinopathy in patients with diabetes mellitus.
Bruijel, Jessica; van der Meijden, Wisse P.; Bijlenga, Denise; Dorani, Farangis; Coppens, Joris E.; te Lindert, Bart H. W.; Kooij, J. J. Sandra; Van Someren, Eus J. W.
2016-01-01
Melanopsin-containing retinal ganglion cells play an important role in the non-image forming effects of light, through their direct projections on brain circuits involved in circadian rhythms, mood and alertness. Individual differences in the functionality of the melanopsin-signaling circuitry can be reliably quantified using the maximum post-illumination pupil response (PIPR) after blue light. Previous protocols for acquiring PIPR relied on the use of mydriatics to dilate the light-exposed eye. However, pharmacological pupil dilation is uncomfortable for the participants and requires ophthalmological expertise. Hence, we here investigated whether an individual’s maximum PIPR can be validly obtained in a protocol that does not use mydriatics but rather increases the intensity of the light stimulus. In 18 participants (5 males, mean age ± SD: 34.6 ± 13.6 years) we evaluated the PIPR after exposure to intensified blue light (550 µW/cm2) provided to an undilated dynamic pupil. The test-retest reliability of the primary PIPR outcome parameter was very high, both between day-to-day assessments (Intraclass Correlation Coefficient (ICC) = 0.85), as well as between winter and summer assessments (ICC = 0.83). Compared to the PIPR obtained with the use of mydriatics and 160 µW/cm2 blue light exposure, the method with intensified light without mydriatics showed almost zero bias according to Bland-Altman plots and had moderate to strong reliability (ICC = 0.67). In conclusion, for PIPR assessments, increasing the light intensity is a feasible and reliable alternative to pupil dilation to relieve the participant’s burden and to allow for performance outside the ophthalmological clinic. PMID:27618116
Bruce, Beau B.; Lamirel, Cédric; Biousse, Valérie; Ward, Antionette; Heilpern, Katherine L.; Newman, Nancy J.; Wright, David W.
2011-01-01
Objectives Examination of the ocular fundus is imperative in many acute medical and neurologic conditions, but direct ophthalmoscopy by non-ophthalmologists is underutilized, poorly performed, and difficult without pharmacologic pupillary dilation. The objective was to examine the feasibility of non-mydriatic fundus photography as a clinical alternative to direct ophthalmoscopy by emergency physicians (EPs). Methods Adult patients presenting to the emergency department (ED) with headache, acute focal neurologic deficit, diastolic blood pressure ≥ 120 mmHg, or acute visual change had ocular fundus photographs taken by nurse practitioners using a non-mydriatic fundus camera. Photographs were reviewed by a neuro-ophthalmologist within 24 hours for findings relevant to acute ED patient care. Nurse practitioners and patients rated ease, comfort, and speed of non-mydriatic fundus photography on a 10-point Likert scale (10 best). Timing of visit and photography were recorded by automated electronic systems. Results Three hundred fifty patients were enrolled. There were 1,734 photographs taken during 230 nurse practitioner shifts. Eighty-three percent of the 350 patients had at least one eye with a high quality photograph, while only 3% of patients had no photographs of diagnostic value. Mean ratings were ≥ 8.7 (standard deviation [SD] ≤ 1.9) for all measures. The median photography session lasted 1.9 minutes (interquartile range [IQR] 1.3 to 2.9 minutes), typically accounting for less that 0.5% of the patient’s total ED visit. Conclusions Non-mydriatic fundus photography taken by nurse practitioners is a feasible alternative to direct ophthalmoscopy in the ED. It is performed well by non-physician staff, is well-received by staff and patients, and requires a trivial amount of time to perform. PMID:21906202
Hargitai, János; Vezendi, László; Vigstrup, Jørgen; Eisgart, Finn; Lundbye-Christensen, Søren; Hargitai, Bálint; Vorum, Henrik
2013-12-20
A strong association exists between the use of tamsulosin and the occurance of intraoperative floppy iris syndrome. Several methods were advocated to overcome the progressive intraopertive miosis.Our purpose was to investigate the effect of a mydriatic-cocktail soaked cellulose sponge on perioperative pupil diameter in tamsulosin-treated patients undergoing elective cataract surgery. Patients using tamsulosin were dilated either with mydriatic-cocktail soaked sponge (group 1) or with conventional eyedrop regimen (group 2). Control patients not taking any α1 adrenergic receptor inhibtors were also dilated with mydriatic sponge (group 3).In all groups oxybuprocain 0.4%, cocain 4%, tropicamide 1%, phenylephrine 10%, diclophenac 0.1% along with chloramphenicol 0.5% were used preoperatively.Pupil diameter (mm) was measured preoperatively, after nucleus delivery, and before IOL implantation. Adverse effects associated with the use of sponge, minor and major intraoperative complications, the use of iris retractors and operation time were recorded.Differences in general between groups were analyzed with a one way analysis of variance (ANOVA); differences between groups in proportions were assessed by Fisher's exact test. Mean pupil diameter (mm) was preopertively: 7.52 ± 1.21, 7.30 ± 1.55 and 7.99 ± 0.96 (ANOVA: p = 0.079); after nucleus delivery: 6 ± 1.20, 6.29 ± 1.12 and 6.52 ± 0.81 (ANOVA: p = 0.123); before IOL implantation: 5.46 ± 1.06, 5.83 ± 1.09 and 6.17 ± 0.89 (ANOVA: p = 0.0291).No adverse effect related to sponge use was detected. Frequency of minor complications, and iris hook use was similar in the two tamsulosin treated group. Operation time did not differ significantly in the three groups. We have found that using a mydriatic cocktail-soaked wick - an alternative way to achieve intraoperative mydriasis for cataract surgery - was as effective and safe as the conventional repeated eyedrops regiment for tamsulosin treated patients. Current Controlled Trials ISRCTN37834752.
Lamirel, Cédric; Bruce, Beau B.; Wright, David W.; Delaney, Kevin P.; Newman, Nancy J.; Biousse, Valérie
2011-01-01
Objective Non-mydriatic fundus photography by non-ophthalmic trained personnel has recently been shown to be a potential alternative to direct ophthalmoscopy in the emergency department (ED). We evaluated the reliability of a novel quality rating scale and applied this scale to non-mydriatic fundus photographs taken during routine ED patient encounters to determine factors associated with diminished photograph quality. Design Prospective, cross-sectional Participants 350 patients enrolled in the Fundus photography vs. Ophthalmoscopy Trials Outcomes in the Emergency Department (FOTO-ED) study were photographed by nurse practitioners after <30 minutes of training followed by supervision. Methods Photographs of both eyes were graded for quality on two occasions by two neuro-ophthalmologists. Four regions were independently evaluated for quality: optic disc, macula, superior and inferior vascular arcades. Quality as a function of the number of photographs taken was evaluated by Kaplan-Meier analysis. Mixed effects ordinal logistic regression was used to evaluate for predictors of image quality while accounting for the repeated measures design. Main Outcome Measure Overall photographic quality (1–5 scale, 5 best). Results We evaluated 1734 photographs. Inter- and intra-observer agreements between neuro-ophthalmologists were very good (weighted kappa:0.84–0.87). Quality of the optic disc area was better than those of other retinal areas (p<0.002). Kaplan-Meier analysis showed that if a high-quality photograph of an eye was not obtained by the third attempt it was unlikely that one would be obtained at all. A 10 second increase in the inter-photograph interval before a total of forty seconds increased the odds of a one unit higher quality rating by 1.81 times (95%CI: 1.68–1.98), and a ten year increase in age decreased the odds by 0.76 times (95%CI: 0.69–0.85). Black patients had 0.42 times (95%CI: 0.28–0.63) the odds of a one unit higher quality rating compared to whites. Conclusions Our 5-point scale is a reliable measure of non-mydriatic photograph quality. The region of interest, interphotograph interval, age, and race are significant predictors of image quality for non-mydriatic photographs taken by nurse practitioners in the ED. Addressing these factors may have a direct impact on the successful implementation of non-mydriatic fundus photography into the ED. PMID:22218140
2013-01-01
Background A strong association exists between the use of tamsulosin and the occurance of intraoperative floppy iris syndrome. Several methods were advocated to overcome the progressive intraopertive miosis. Our purpose was to investigate the effect of a mydriatic-cocktail soaked cellulose sponge on perioperative pupil diameter in tamsulosin-treated patients undergoing elective cataract surgery. Methods Patients using tamsulosin were dilated either with mydriatic-cocktail soaked sponge (group 1) or with conventional eyedrop regimen (group 2). Control patients not taking any α1 adrenergic receptor inhibtors were also dilated with mydriatic sponge (group 3). In all groups oxybuprocain 0.4%, cocain 4%, tropicamide 1%, phenylephrine 10%, diclophenac 0.1% along with chloramphenicol 0.5% were used preoperatively. Pupil diameter (mm) was measured preoperatively, after nucleus delivery, and before IOL implantation. Adverse effects associated with the use of sponge, minor and major intraoperative complications, the use of iris retractors and operation time were recorded. Differences in general between groups were analyzed with a one way analysis of variance (ANOVA); differences between groups in proportions were assessed by Fisher’s exact test. Results Mean pupil diameter (mm) was preopertively: 7.52 ± 1.21, 7.30 ± 1.55 and 7.99 ± 0.96 (ANOVA: p = 0.079); after nucleus delivery: 6 ± 1.20, 6.29 ± 1.12 and 6.52 ± 0.81 (ANOVA: p = 0.123); before IOL implantation: 5.46 ± 1.06, 5.83 ± 1.09 and 6.17 ± 0.89 (ANOVA: p = 0.0291). No adverse effect related to sponge use was detected. Frequency of minor complications, and iris hook use was similar in the two tamsulosin treated group. Operation time did not differ significantly in the three groups. Conclusion We have found that using a mydriatic cocktail-soaked wick – an alternative way to achieve intraoperative mydriasis for cataract surgery – was as effective and safe as the conventional repeated eyedrops regiment for tamsulosin treated patients. Trial registration Current Controlled Trials ISRCTN37834752 PMID:24359572
Pupil dilation using a pledget sponge: a randomized controlled trial.
McCormick, Austin; Srinivasan, Sathish; Harun, Shabbir; Watts, Mark
2006-08-01
To show that a pledget soaked in mydriatics and placed in the lower conjunctival fornix is as effective as drops in providing mydriasis for cataract surgery. A randomized, masked, controlled trial of 56 patients assigned to either a pledget group (n=25) or a control eye drops group (n=31) was carried out. Controls had the routine practice of repeated topical mydriatic drops: tropicamide, phenylepherine and atropine. The trial group had a 3-mm pledget trimmed, soaked in mydriatics and placed in the inferior fornix for 20 min. Pupil diameter was measured using a photographic technique with a standard scale shown in each picture. Two masked observers measured the pupils using the scale of the ruler in the developed photograph. All patients completed a 0-10 stinging score prior to surgery. There were no complications. The mean pupil diameter in the control group was 7.23 (6.91-7.94 95% confidence intervals [CI]) and 7.44 (6.96-7.92 95% CI) in the pledget group. There was no statistically significant difference in pupil diameter between the two groups: difference between means 0.21 (-0.32 to 0.75 95% CI) and Student's t-test of the difference between means (t=0.8 and two-tailed) probability P=0.43. There was no significant difference in the stinging scores: Mann-Whitney test P=0.69. The use of a pledget cellulose sponge to deliver mydriatics prior to cataract surgery is as effective as the conventional method of repeated drop administration and was not associated with any adverse effects.
Phiri, R; Keeffe, J E; Harper, C A; Taylor, H R
2006-08-01
To show that the non-mydriatic retinal camera (NMRC) using polaroid film is as effective as the NMRC using digital imaging in detecting referrable retinopathy. A series of patients with diabetes attending the eye out-patients department at the Royal Victorian Eye and Ear Hospital had single-field non-mydriatic fundus photographs taken using first a digital and then a polaroid camera. Dilated 30 degrees seven-field stereo fundus photographs were then taken of each eye as the gold standard. The photographs were graded in a masked fashion. Retinopathy levels were defined using the simplified Wisconsin Grading system. We used the kappa statistics for inter-reader and intrareader agreement and the generalized linear model to derive the odds ratio. There were 196 participants giving 325 undilated retinal photographs. Of these participants 111 (57%) were males. The mean age of the patients was 68.8 years. There were 298 eyes with all three sets of photographs from 154 patients. The digital NMRC had a sensitivity of 86.2%[95% confidence interval (CI) 65.8, 95.3], whilst the polaroid NMRC had a sensitivity of 84.1% (95% CI 65.5, 93.7). The specificities of the two cameras were identical at 71.2% (95% CI 58.8, 81.1). There was no difference in the ability of the polaroid and digital camera to detect referrable retinopathy (odds ratio 1.06, 95% CI 0.80, 1.40, P = 0.68). This study suggests that non-mydriatic retinal photography using polaroid film is as effective as digital imaging in the detection of referrable retinopathy in countries such as the USA and Australia or others that use the same criterion for referral.
Ryan, Martha E; Rajalakshmi, Ramachandran; Prathiba, Vijayaraghavan; Anjana, Ranjit Mohan; Ranjani, Harish; Narayan, K M Venkat; Olsen, Timothy W; Mohan, Viswanathan; Ward, Laura A; Lynn, Michael J; Hendrick, Andrew M
2015-10-01
We compared smartphone fundus photography, nonmydriatic fundus photography, and 7-field mydriatic fundus photography for their abilities to detect and grade diabetic retinopathy (DR). This was a prospective, comparative study of 3 photography modalities. Diabetic patients (n = 300) were recruited at the ophthalmology clinic of a tertiary diabetes care center in Chennai, India. Patients underwent photography by all 3 modalities, and photographs were evaluated by 2 retina specialists. The sensitivity and specificity in the detection of DR for both smartphone and nonmydriatic photography were determined by comparison with the standard method, 7-field mydriatic fundus photography. The sensitivity and specificity of smartphone fundus photography, compared with 7-field mydriatic fundus photography, for the detection of any DR were 50% (95% confidence interval [CI], 43-56) and 94% (95% CI, 92-97), respectively, and of nonmydriatic fundus photography were 81% (95% CI, 75-86) and 94% (95% CI, 92-96%), respectively. The sensitivity and specificity of smartphone fundus photography for the detection of vision-threatening DR were 59% (95% CI, 46-72) and 100% (95% CI, 99-100), respectively, and of nonmydriatic fundus photography were 54% (95% CI, 40-67) and 99% (95% CI, 98-100), respectively. Smartphone and nonmydriatic fundus photography are each able to detect DR and sight-threatening disease. However, the nonmydriatic camera is more sensitive at detecting DR than the smartphone. At this time, the benefits of the smartphone (connectivity, portability, and reduced cost) are not offset by the lack of sufficient sensitivity for detection of DR in most clinical circumstances. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Barcatali, M-G; Denion, E; Miocque, S; Reznik, Y; Joubert, M; Morera, J; Rod, A; Mouriaux, F
2015-04-01
Since 2010, the High Authority for health (HAS) recommends the use of non-mydriatic fundus camera for diabetic retinopathy screening. The purpose of this study is to evaluate the results of screening for diabetic retinopathy using the non-mydriatic retinal camera by a physician's assistant in the endocrinology service. This is a retrospective study of all diabetic patients hospitalized in the endocrinology department between May 2013 and November 2013. For each endocrinology patient requiring screening, a previously trained physician's assistant performed fundus photos. The ophthalmologist then provided a written interpretation of the photos on a consultant's sheet. Of the 120 patients screened, 40 (33.3%) patients had uninterpretable photos. Among the 80 interpretable photos, 64 (53.4%) patients had no diabetic retinopathy, and 16 (13.3%) had diabetic retinopathy. No patient had diabetic maculopathy. Specific quality criteria were established by the HAS for screening for diabetic retinopathy using the non-mydriatic retinal camera in order to ensure sufficient sensitivity and specificity. In our study, the two quality criteria were not achieved: the rates of uninterpretable photos and the total number of photos analyzed in a given period. In our center, we discontinued this method of diabetic retinopathy screening due to the high rate of uninterpretable photos. Due to the logistic impossibility of the ophthalmologists taking all the fundus photos, we proposed that the ophthalmic nurses take the photos. They are better trained in the use of the equipment, and can confer directly with an ophthalmologist in questionable cases and to obtain pupil dilation as necessary. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Chiambaretta, Frederic; Pleyer, Uwe; Behndig, Anders; Pisella, Pierre-Jean; Mertens, Erik; Limao, Antonio; Fasce, Francesco; Fernandez, Joaquin; Benmoussa, Salah-Eddine; Labetoulle, Marc; Cochener, Beatrice
2018-03-01
To compare the pupil dynamics of an intracameral combination of 2 mydriatics and 1 anesthetic (Mydrane) to a standard topical regimen for cataract surgery. Sixty-two centers in Europe and 6 centers in Algeria. Prospective case series. Pupil size measurements were performed in 2 randomized studies (phase 2 and phase 3) under masked conditions (recorded videography, masked reading center). The outcomes in the phase 2 study supported evaluation of the timeframe to obtain pupil dilation and the phase 3 study provided results on mydriasis stability. Phase 2 and phase 3 comprised 139 patients and 591 patients, respectively. After intracameral combination administration, 95% of the pupil dilation was achieved within a mean of 28.6 seconds ± 4.6 (SD). At the beginning of capsulorhexis creation, the mean pupil diameter was larger than 7.0 mm in both groups. The intraoperative pupil diameter remained stable in the intracameral combination group and decreased in the topical group. The mean change in pupil size just before capsulorhexis to the end of surgery (just before cefuroxime injection) was -0.22 ± 0.72 mm and -1.67 ± 0.98 mm, respectively. No clinically significant change in pupil diameter (change <1.0 mm) occurred in the majority of the intracameral combination group (89.3%) compared with the topical group (26.8%). Intracameral combination of 2 mydriatics and 1 anesthetic is an alternative to topical mydriatics for cataract surgery. The prompt onset of pupil dilation and the stable mydriasis induced by this drug combination improved the intraoperative conditions during crucial steps, such as intraocular lens implantation. Copyright © 2018. Published by Elsevier Inc.
Non-mydriatic fundus photography: a practical review for the neurologist.
Mackay, Devin D; Bruce, Beau B
2016-10-01
Declining proficiency in direct ophthalmoscopy by non-ophthalmologists has spurred a search for alternative methods of ocular fundus examination. Recent technological advances have improved the ease of use and quality of non-mydriatic fundus photography, increasing its suitability for clinical care. As the availability of this technology continues to improve, neurologists will need to be familiar with its advantages, limitations and potential applications in the clinical care of patients with neurological conditions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Non-mydriatic ocular fundus photography in the emergency department: how it can benefit neurologists
Bruce, Beau B.
2016-01-01
Examination of the ocular fundus is a critical aspect of the neurological examination. For example, in patients with headache the ocular fundus examination is needed to uncover “red flags” suggestive of secondary etiologies. However, ocular fundus examination is infrequently and poorly performed in clinical practice. Non-mydriatic ocular fundus photography provides an alternative to direct ophthalmoscopy that has been studied as part of the Fundus photography vs. Ophthalmoscopy Trial Outcomes in the Emergency Department (FOTO-ED) study. Herein, we review the results of the FOTO-ED study with a particular focus on the study's implications for the acute care of patients presenting with headache and focal neurologic deficits. In headache patients, we not only observed optic disc edema and optic disc pallor as would be expected, but also a large number of abnormalities associated with hypertension. Based upon subjects with focal neurological deficits, the FOTO-ED study suggests that the ocular fundus examination may assist with the triage of patients presenting with suspected transient ischemic attack. Continued advances in the ease and portability of non-mydriatic fundus photography will hopefully help to restore ocular fundus examination as a routinely performed component of all neurological examinations. PMID:26444394
Verma, Purnima; Ahuja, Munish
2016-10-01
The purpose of this study was to investigate the potential of cubic liquid crystalline nanoparticles for ocular delivery of tropicamide. Ultrasound-assisted fragmentation of cubic liquid crystalline bulk phases resulted in cubic liquid crystalline nanoparticles employing Pluronic F127 as dispersant. The effects of process variables such as sonication time, sonication amplitude, sonication depth, and pre-mixing time on particle size and polydispersity index was investigated using central composite design. The morphology of tropicamide-loaded nanoparticles was found to be nearly cubical in shape by transmission electron microscopy observation. Further, small angle X-ray scattering experiment confirmed the presence of D and P phase cubic structures in coexistence. The optimized tropicamide-loaded cubic nanoparticles showed in vitro corneal permeation of tropicamide across isolated porcine cornea comparable to its commercial preparation, Tropicacyl®. Ocular tolerance was evaluated by Hen's egg-chorioallantoic membrane test and histological studies. The results of in vivo mydriatic response study demonstrated a remarkably higher area under mydriatic response curve (AUC 0→1440 min ) values of cubic nanoparticles over Tropicacyl® indicating better therapeutic value of cubic nanoparticles. Furthermore, tropicamide-loaded cubic nanoparticles exhibited prolonged mydriatic effect on rabbits as compared to commercial conventional aqueous ophthalmic solution.
Fatal necrotising enterocolitis due to mydriatic eye drops.
Ozgun, Uygur; Demet, Terek; Ozge, Koroglu A; Zafer, Dokumcu; Murat, Sezak; Mehmet, Yalaz; Nilgun, Kultursay
2014-05-01
Retinopathy of prematurity (ROP) is a serious problem of preterm infants which may lead to impairment of vision and even to blindness if untreated. Routine eye examination is necessary for early diagnosis and treatment of ROP in preterm infants. Mydriatic eye drops (cyclopentolate, tropicamide and phenylephrine) are applied before the ophthalmic examination. These agents are rarely absorbed to systemic circulation and in some cases result with serious side effects like skin rash, tachycardia, feeding intolerance, discomfort, apnea, gastric dilatation and ileus, despite different treatment models and dosage reducing strategies. We report here a preterm patient who died because of severe diffuse necrotizing enterocolitis (NEC) after topical application of 0.5% cyclopentolate and 1.25% phenylephrine during ROP screening to emphasise the serious side effects of these agents.
Sensitivity and specificity of digital retinal imaging for screening diabetic retinopathy.
Lopez-Bastida, J; Cabrera-Lopez, F; Serrano-Aguilar, P
2007-04-01
To assess the effectiveness of a non-mydriatic digital camera (45 degrees -30 degrees photographs) compared with the reference method for screening diabetic retinopathy. Type 1 and 2 diabetic patients (n = 773; 1546 eyes) underwent screening for diabetic retinopathy in a prospective observational study. Hospital-based non-mydriatic digital retinal imaging by a consultant specialist in retinal diseases was compared with slit-lamp biomicroscopy and indirect ophthalmoscopy through dilated pupils, as a gold standard, previously performed in a community health centre by another consultant specialist in retinal diseases. The main outcome measures were sensitivity and specificity of screening methods and prevalence of diabetic retinopathy. The prevalence of any form of diabetic retinopathy was 42.4% (n = 328); the prevalence of sight-threatening including macular oedema and proliferative retinopathy was 9.6% (n = 74). Sensitivity of detection of any diabetic retinopathy by digital imaging was 92% (95% confidence interval 90, 94). Specificity of detection of any diabetic retinopathy was 96% (95, 98). The predictive value of the negative tests was 94% and of a positive test 95%. For sight-threatening retinopathy digital imaging had a sensitivity of 100%. A high sensitivity and specificity are essential for an effective screening programme. These results confirm digital retinal imaging with a non-mydriatic camera as an effective option in community-based screening programmes for diabetic retinopathy.
Anisocoria and Horner's Syndrome
... and how they react to bright and dim lighting. Based on the evaluation, the doctor may wish ... the difference in pupil size increases in bright lighting, then the larger (mydriatic) pupil may be the ...
Cunha, Leonardo Provetti; Figueiredo, Evelyn Alvernaz; Araújo, Henrique Pereira; Costa-Cunha, Luciana Virgínia Ferreira; Costa, Carolina Ferreira; Neto, José de Melo Costa; Matos, Aline Mota Freitas; de Oliveira, Marise Machado; Bastos, Marcus Gomes; Monteiro, Mário Luiz Ribeiro
2018-01-01
To determine the level of agreement between trained family physicians (FPs), general ophthalmologists (GOs), and a retinal specialist (RS) in the assessment of non-mydriatic fundus retinography in screening for diabetic retinopathy (DR) in the primary health-care setting. 200 Diabetic patients were submitted to two-field non-mydriatic digital fundus camera. The images were examined by four trained FPs, two GOs, and one RS with regard to the diagnosis and severity of DR and the diagnosis of macular edema. The RS served as gold standard. Reliability and accuracy were determined with the kappa test and diagnostic measures. A total of 397 eyes of 200 patients were included. The mean age was 55.1 (±11.7) years, and 182 (91%) had type 2 diabetes. The mean levels of serum glucose and glycosylated hemoglobin A1c were 195.6 (±87.3) mg/dL and 8.9% (±2.1), respectively. DR was diagnosed in 166 eyes by the RS and in 114 and 182 eyes by GO 1 and GO 2 , respectively. For severity, DR was graded as proliferative in 8 eyes by the RS vs. 15 and 9 eyes by GO 1 and GO 2 , respectively. The agreement between the RS and the GOs was substantial for both DR diagnosis (GO 1 k = 0.65; GO 2 k = 0.74) and severity (GO 1 k = 0.60; GO 2 k = 0.71), and fair or moderate for macular edema (GO 1 k = 0.27; GO 2 k = 0.43). FP 1 , FP 2 , FP 3 , and FP 4 diagnosed DR in 108, 119, 163, and 117 eyes, respectively. The agreement between the RS and the FPs with regard to DR diagnosis was substantial (FP 2 k = 0.69; FP 3 k = 0.73; FP 4 k = 0.71) or moderate (FP 1 k = 0.56). As for DR severity, the agreement between the FPs and the RS was substantial (FP 2 k = 0.66; FP 3 k = 069; FP 4 k = 0.64) or moderate (FP 1 k = 0.51). Agreement between the FPs and the RS with regard to macular edema was fair (FP 1 k = 0.33; FP 2 k = 0.39; FP 3 k = 0.37) or moderate (FP 4 k = 0.51). Non-mydriatic fundus retinography was shown to be useful in DR screening in the primary health-care setting. FPs made assessments with good levels of agreement with an RS. Non-mydriatic fundus retinography associated with appropriate general physicians training is essential for the DR screening.
Pérez-Cambrodí, Rafael José; Piñero-Llorens, David Pablo; Ruiz-Fortes, Juan Pedro; Blanes-Mompó, Francisco Javier; Cerviño-Expósito, Alejandro
2014-07-01
We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.
Human Visual System-Based Fundus Image Quality Assessment of Portable Fundus Camera Photographs.
Wang, Shaoze; Jin, Kai; Lu, Haitong; Cheng, Chuming; Ye, Juan; Qian, Dahong
2016-04-01
Telemedicine and the medical "big data" era in ophthalmology highlight the use of non-mydriatic ocular fundus photography, which has given rise to indispensable applications of portable fundus cameras. However, in the case of portable fundus photography, non-mydriatic image quality is more vulnerable to distortions, such as uneven illumination, color distortion, blur, and low contrast. Such distortions are called generic quality distortions. This paper proposes an algorithm capable of selecting images of fair generic quality that would be especially useful to assist inexperienced individuals in collecting meaningful and interpretable data with consistency. The algorithm is based on three characteristics of the human visual system--multi-channel sensation, just noticeable blur, and the contrast sensitivity function to detect illumination and color distortion, blur, and low contrast distortion, respectively. A total of 536 retinal images, 280 from proprietary databases and 256 from public databases, were graded independently by one senior and two junior ophthalmologists, such that three partial measures of quality and generic overall quality were classified into two categories. Binary classification was implemented by the support vector machine and the decision tree, and receiver operating characteristic (ROC) curves were obtained and plotted to analyze the performance of the proposed algorithm. The experimental results revealed that the generic overall quality classification achieved a sensitivity of 87.45% at a specificity of 91.66%, with an area under the ROC curve of 0.9452, indicating the value of applying the algorithm, which is based on the human vision system, to assess the image quality of non-mydriatic photography, especially for low-cost ophthalmological telemedicine applications.
A Multi-Center Diabetes Eye Screening Study in Community Settings: Study Design and Methodology.
Murchison, Ann P; Friedman, David S; Gower, Emily W; Haller, Julia A; Lam, Byron L; Lee, David J; McGwin, Gerald; Owsley, Cynthia; Saaddine, Jinan; Insight Study Group
2016-01-01
Diabetes is the leading cause of new cases of blindness among adults aged 20-74 years within the United States. The Innovative Network for Sight Research group (INSIGHT) designed the Diabetic Eye Screening Study (DESS) to examine the feasibility and short-term effectiveness of non-mydriatic diabetic retinopathy (DR) screening for adults with diabetes in community-based settings. Study enrollment began in December 2011 at four sites: an internal medicine clinic at a county hospital in Birmingham, Alabama; a Federally-qualified community healthcare center in Miami-Dade County, Florida; a university-affiliated outpatient pharmacy in Philadelphia, Pennsylvania; and a medical home in Winston-Salem, North Carolina. People 18 years or older with previously diagnosed diabetes were offered free DR screening using non-mydriatic retinal photography that was preceded by a brief questionnaire addressing demographic information and previous eye care use. Visual acuity was also measured for each eye. Images were evaluated at a telemedicine reading center by trained evaluators using the National Health System DR grading classification. Participants and their physicians were sent screening report results and telephoned for a follow-up survey 3 months post-screening to determine whether participants had sought follow-up comprehensive eye care and their experiences with the screening process. Target enrollment at each site was a minimum of 500 persons. Three of the four sites met this enrollment goal. The INSIGHT/DESS is intended to establish the feasibility and short-term effectiveness of DR screening using non-mydriatic retinal photography in persons with diabetes who seek services in community-based clinic and pharmacy settings.
Raczak-Gutknecht, Joanna; Nasal, Antoni; Frąckowiak, Teresa; Kornicka, Anita; Sączewski, Franciszek; Wawrzyniak, Renata; Kubik, Łukasz; Kaliszan, Roman
2017-09-10
Imidazol(in)e derivatives, having the chemical structure similar to clonidine, exert diverse pharmacological activities connected with their interactions with alpha2-adrenergic receptors, e.g. hypotension, bradycardia, sedation as well as antinociceptive, anxiolytic, antiarrhythmic, muscle relaxant and mydriatic effects. The mechanism of pupillary dilation observed after systemic administration of imidazol(in)es to rats, mice and cats depends on the stimulation of postsynaptic alpha2-adrenoceptors within the brain. It was proved that the central nervous system (CNS)-localized I1-imidazoline receptors are not engaged in those effects. It appeared interesting to analyze the CNS-mediated pharmacodynamics of imidazole(in)e agents in terms of their chromatographic and calculation chemistry-derived parameters. In the present study a systematic determination and comparative pharmacometric analysis of mydriatic effects in rats were performed on a series of 20 imidazol(in)e agents, composed of the well-known drugs and of the substances used in experimental pharmacology. The eye pupil dilatory activities of the compounds were assessed in anesthetized Wistar rats according to the established Koss method. Among twenty imidazol(in)e derivatives studied, 18 produced diverse dose-dependent mydriatic effects. In the quantitative structure-activity relationships (QSAR) analysis, the pharmacological data (half maximum mydriatic effect - ED 50 in μmol/kg) were considered along with the structural parameters of the agents from molecular modeling. The theoretically calculated lipophilicity parameters, CLOGP, of imidazol(in)es, as well as their lipophilicity parameters from HPLC, logk w , were also considered. The attempts to derive statistically significant QSAR equations for a full series of the agents under study were unsuccessful. However, for a subgroup of eight apparently structurally related imidazol(in)es a significant relationship between log(1/ED 50 ) and logk w values was obtained. The lack of "predictive" QSAR for the whole series of the structurally diverse agents is probably due to a complex mechanism of the ligand-alpha2-adrenergic receptor interactions, which are predominantly of a highly structurally specific polar nature. Such interactions are difficult to quantify with the established chemical structural descriptors, contrary to the less specific, molecular bulkiness-related interactions. Copyright © 2017 Elsevier B.V. All rights reserved.
Labetoulle, Marc; Findl, Oliver; Malecaze, François; Alió, Jorge; Cochener, Béatrice; Lobo, Conceição; Lazreg, Sihem; Hartani, Dahbia; Colin, Joseph; Tassignon, Marie-José; Behndig, Anders
2016-01-01
Background/aims To compare the efficacy and safety of intracameral (IC) administration at the beginning of cataract surgery, of Mydrane, a standardised ophthalmic combination of tropicamide 0.02%, phenylephrine 0.31% and lidocaine 1%, to a standard topical regimen. Methods In this international phase III, prospective, randomised study, the selected eye of 555 patients undergoing phacoemulsification with intraocular lens (IOL) implantation received 200 μL of Mydrane (Mydrane group) just after the first incision or a topical regimen of one drop each of tropicamide 0.5% and phenylephrine 10% repeated three times (reference group). The primary efficacy variable was achievement of capsulorhexis without additional mydriatics. The non-inferiority of Mydrane to the topical regimen was tested. The main outcome measures were pupil size, patient perception of ocular discomfort and safety. Results Capsulorhexis without additional mydriatics was performed in 98.9% of patients and 94.7% in the Mydrane and reference groups, respectively. Both groups achieved adequate mydriasis (>7 mm) during capsulorhexis, phacoemulsification and IOL insertion. IOL insertion was classified as ‘routine’ in a statistically greater number of eyes in the Mydrane group compared with the reference group (p=0.047). Patients in the Mydrane group reported statistically greater comfort than the reference group before IOL insertion (p=0.034). Safety data were similar between groups. Conclusions Mydrane is an effective and safe alternative to standard eye drops for initiating and maintaining intraoperative mydriasis and analgesia. Patients who received IC Mydrane were significantly more comfortable before IOL insertion than the reference group. Surgeons found IOL insertion less technically challenging with IC Mydrane. Trial registration number NCT02101359; Results. PMID:26531052
Petritz, Olivia A; Guzman, David Sanchez-Migallon; Gustavsen, Kate; Wiggans, K Tomo; Kass, Philip H; Houck, Emma; Murphy, Christopher J; Paul-Murphy, Joanne
2016-01-01
OBJECTIVE :To determine the mydriatic effects of topical rocuronium bromide administration in Hispaniolan Amazon parrots (Amazona ventralis) and to identify any adverse effects associated with treatment. Randomized crossover study. 8 healthy adult Hispaniolan Amazon parrots. Rocuronium bromide (20 μL/eye; 10 mg/mL) or saline (20 μL/eye; 0.9% NaCl) solution was administered in both eyes of each bird with a 26-day washout period. The birds were manually restrained in lateral recumbency with the apex of the cornea positioned upward for 2 minutes following administration in each eye. Infrared pupillometry and direct pupillary light reflex measurements were used to evaluate the mydriatic effects. Pupillary measurements were recorded prior to administration and every 20 minutes for 2 hours after administration, then hourly for a total of 7 hours. A brief physical examination was performed, direct pupillary light reflex was tested, and fluorescein staining was performed on each eye of each bird 24 hours after administration. A significant difference in pupillary diameter for the active versus control treatment group was noted from 20 to 360 minutes after drug administration, but not at 420 minutes. Minimal adverse effects were noted. Three birds had transient inferior eyelid paresis noted in both eyes after receiving rocuronium; 24 hours after the treatment, no differences in ocular measurements existed between the active and control treatments. Results suggested that topical rocuronium bromide administration may be safely used for pupillary dilation in Hispaniolan Amazon parrots and could be used for clinical evaluation, fundus imaging, and surgical interventions involving the lens and posterior segment in this species.
Kernt, Marcus; Hadi, Indrawati; Pinter, Florian; Seidensticker, Florian; Hirneiss, Christoph; Haritoglou, Christos; Kampik, Anselm; Ulbig, Michael W.; Neubauer, Aljoscha S.
2012-01-01
OBJECTIVE To compare the diagnostic properties of a nonmydriatic 200° ultra-widefield scanning laser ophthalmoscope (SLO) versus mydriatic Early Treatment of Diabetic Retinopathy Study (ETDRS) 7-field photography for diabetic retinopathy (DR) screening. RESEARCH DESIGN AND METHODS A consecutive series of 212 eyes of 141 patients with different levels of DR were examined. Grading of DR and clinically significant macular edema (CSME) from mydriatic ETDRS 7-field stereo photography was compared with grading obtained by Optomap Panoramic 200 SLO images. All SLO scans were performed through an undilated pupil, and no additional clinical information was used for evaluation of all images by the two independent, masked, expert graders. RESULTS Twenty-two eyes from ETDRS 7-field photography and 12 eyes from Optomap were not gradable by at least one grader because of poor image quality. A total of 144 eyes were analyzed regarding DR level and 155 eyes regarding CSME. For ETDRS 7-field photography, 22 eyes (18 for grader 2) had no or mild DR (ETDRS levels ≤ 20) and 117 eyes (111 for grader 2) had no CSME. A highly substantial agreement between both Optomap DR and CSME grading and ETDRS 7-field photography existed with κ = 0.79 for DR and 0.73 for CSME for grader 1, and κ = 0.77 (DR) and 0.77 (CSME) for grader 2. CONCLUSIONS Determination of CSME and grading of DR level from Optomap Panoramic 200 nonmydriatic images show a positive correlation with mydriatic ETDRS 7-field stereo photography. Both techniques are of sufficient quality to assess DR and CSME. Optomap Panoramic 200 images cover a larger retinal area and therefore may offer additional diagnostic properties. PMID:22912430
Comparison Among Methods of Retinopathy Assessment (CAMRA) Study
Ryan, Martha E.; Rajalakshmi, Ramachandran; Prathiba, Vijayaraghavan; Anjana, Ranjit Mohan; Ranjani, Harish; Narayan, K.M. Venkat; Olsen, Timothy W.; Mohan, Viswanathan; Ward, Laura A.; Lynn, Michael J.; Hendrick, Andrew M.
2015-01-01
Purpose We compared smartphone fundus photography, nonmydriatic fundus photography, and 7-field mydriatic fundus photography for their abilities to detect and grade diabetic retinopathy (DR). Design This was a prospective, comparative study of 3 photography modalities. Participants Diabetic patients (n = 300) were recruited at the ophthalmology clinic of a tertiary diabetes care center in Chennai, India. Methods Patients underwent photography by all 3 modalities, and photographs were evaluated by 2 retina specialists. Main Outcome Measures The sensitivity and specificity in the detection of DR for both smartphone and nonmydriatic photography were determined by comparison with the standard method, 7-field mydriatic fundus photography. Results The sensitivity and specificity of smartphone fundus photography, compared with 7-field mydriatic fundus photography, for the detection of any DR were 50% (95% confidence interval [CI], 43–56) and 94% (95% CI, 92–97), respectively, and of nonmydriatic fundus photography were 81% (95% CI, 75–86) and 94% (95% CI, 92–96%), respectively. The sensitivity and specificity of smartphone fundus photography for the detection of vision-threatening DR were 59% (95% CI, 46–72) and 100% (95% CI, 99–100), respectively, and of nonmydriatic fundus photography were 54% (95% CI, 40–67) and 99% (95% CI, 98–100), respectively. Conclusions Smartphone and nonmydriatic fundus photography are each able to detect DR and sight-threatening disease. However, the nonmydriatic camera is more sensitive at detecting DR than the smartphone. At this time, the benefits of the smartphone (connectivity, portability, and reduced cost) are not offset by the lack of sufficient sensitivity for detection of DR in most clinical circumstances. PMID:26189190
Kernt, Marcus; Hadi, Indrawati; Pinter, Florian; Seidensticker, Florian; Hirneiss, Christoph; Haritoglou, Christos; Kampik, Anselm; Ulbig, Michael W; Neubauer, Aljoscha S
2012-12-01
To compare the diagnostic properties of a nonmydriatic 200° ultra-widefield scanning laser ophthalmoscope (SLO) versus mydriatic Early Treatment of Diabetic Retinopathy Study (ETDRS) 7-field photography for diabetic retinopathy (DR) screening. A consecutive series of 212 eyes of 141 patients with different levels of DR were examined. Grading of DR and clinically significant macular edema (CSME) from mydriatic ETDRS 7-field stereo photography was compared with grading obtained by Optomap Panoramic 200 SLO images. All SLO scans were performed through an undilated pupil, and no additional clinical information was used for evaluation of all images by the two independent, masked, expert graders. Twenty-two eyes from ETDRS 7-field photography and 12 eyes from Optomap were not gradable by at least one grader because of poor image quality. A total of 144 eyes were analyzed regarding DR level and 155 eyes regarding CSME. For ETDRS 7-field photography, 22 eyes (18 for grader 2) had no or mild DR (ETDRS levels ≤ 20) and 117 eyes (111 for grader 2) had no CSME. A highly substantial agreement between both Optomap DR and CSME grading and ETDRS 7-field photography existed with κ = 0.79 for DR and 0.73 for CSME for grader 1, and κ = 0.77 (DR) and 0.77 (CSME) for grader 2. Determination of CSME and grading of DR level from Optomap Panoramic 200 nonmydriatic images show a positive correlation with mydriatic ETDRS 7-field stereo photography. Both techniques are of sufficient quality to assess DR and CSME. Optomap Panoramic 200 images cover a larger retinal area and therefore may offer additional diagnostic properties.
The effect of mydriasis from phenylephrine on corneal shape.
Huang, Ronnie Y C; Lam, Andrew K C
2007-01-01
A previous study reported that pharmacologically-dilated pupils changed the corneal shape. Researchers used mydriatic agents with significant cycloplegic effect. The current study investigates the effect of mydriasis on corneal shape using phenylephrine alone, where phenylephrine has minimal effect on the accommodative system and whether corneal topography can be done after pupil dilation. Forty-four young healthy subjects with one eye randomly selected for mydriasis were used in this study. Twenty-two received one drop of 2.5% phenylephrine (group 1); the other 22 subjects had one drop of 0.4% benoxinate instilled prior to the application of 2.5% phenylephrine (group 2). They were matched for age and refractive error. Anterior chamber depth, pupil size and corneal parameters were compared before and after mydriasis. The corneal parameters included best-fit sphere (BFS), surface asymmetry index (SAI), surface regularity index (SRI) and the axial and tangential powers in the form of flattest and steepest powers, and in the form of M, J(0), and J(45) vector presentation. Group 1 and group 2 subjects had similar pre-mydriatic baseline ocular parameters. The mean (+/- SD) pupil dilation was 1.24 +/- 0.59 mm for group 1 and 1.80 +/- 0.95 mm for group 2. The dilation was significantly larger in group 2 (unpaired t-tests: t = 2.36, p = 0.02). There were no significant changes in corneal parameters from mydriasis in either group. Previous investigations used mydriatic agents, which affected not only the pupil size but also accommodation. The current study found that mydriasis from phenylephrine, with minimal effect on accommodation, did not result in significant corneal alteration, and corneal topography can be measured after pupil dilation with phenylephrine.
Labetoulle, Marc; Findl, Oliver; Malecaze, François; Alió, Jorge; Cochener, Béatrice; Lobo, Conceição; Lazreg, Sihem; Hartani, Dahbia; Colin, Joseph; Tassignon, Marie-José; Behndig, Anders
2016-07-01
To compare the efficacy and safety of intracameral (IC) administration at the beginning of cataract surgery, of Mydrane, a standardised ophthalmic combination of tropicamide 0.02%, phenylephrine 0.31% and lidocaine 1%, to a standard topical regimen. In this international phase III, prospective, randomised study, the selected eye of 555 patients undergoing phacoemulsification with intraocular lens (IOL) implantation received 200 μL of Mydrane (Mydrane group) just after the first incision or a topical regimen of one drop each of tropicamide 0.5% and phenylephrine 10% repeated three times (reference group). The primary efficacy variable was achievement of capsulorhexis without additional mydriatics. The non-inferiority of Mydrane to the topical regimen was tested. The main outcome measures were pupil size, patient perception of ocular discomfort and safety. Capsulorhexis without additional mydriatics was performed in 98.9% of patients and 94.7% in the Mydrane and reference groups, respectively. Both groups achieved adequate mydriasis (>7 mm) during capsulorhexis, phacoemulsification and IOL insertion. IOL insertion was classified as 'routine' in a statistically greater number of eyes in the Mydrane group compared with the reference group (p=0.047). Patients in the Mydrane group reported statistically greater comfort than the reference group before IOL insertion (p=0.034). Safety data were similar between groups. Mydrane is an effective and safe alternative to standard eye drops for initiating and maintaining intraoperative mydriasis and analgesia. Patients who received IC Mydrane were significantly more comfortable before IOL insertion than the reference group. Surgeons found IOL insertion less technically challenging with IC Mydrane. NCT02101359; Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Idiopathic glaucoma in an 11-year-old crossbred mare.
Rizzo, Daniella
2017-05-01
An 11-year-old crossbred mare was presented with left eye buphthalmia, a mydriatic minimally responsive pupil, locally extensive ventral corneal edema, and corneal striae. Intraocular pressures exceeding 80 mmHg lead to a presumptive diagnosis of glaucoma. Following several days of treatment there was no improvement and enucleation was performed.
Romero, Pedro; Sagarra, Ramon; Ferrer, Jeroni; Fernández-Ballart, Juan; Baget, Marc
2010-05-01
To evaluate the inclusion of family physicians in screening for diabetic retinopathy. We evaluated by non-mydriatic fundus camera 2779 diabetic patients. The family physicians made an initial evaluation of the fundus and pathological images were sent to a reference ophthalmologist. An audit was taken of all the patients at the end of the study. We analysed the concordance in: diabetic retinopathy, diabetic macular edema, and lesions in the macular area. Diabetic retinopathy was observed in 226 patients (8.1%) and diabetic macular edema in 40 patients (1.4%). Other retinal pathologies were diagnosed in 291 (11.0%). The sensitivity of the study was 95.2% for diabetic retinopathy, 96.0% for macular lesions and 92.9% for diabetic macular edema. The specificity was above 98% in the three studied variables. Cohen's Kappa coefficient was 0.82 for diabetic retinopathy, 0.81 for diabetic macular edema and 0.96 for macular lesions. The inclusion of family physicians in the screening system seems to be effective in the diagnosis of diabetic retinopathy. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
Screening Intervals for Diabetic Retinopathy and Implications for Care.
Scanlon, Peter H
2017-09-05
The purpose of this study is to review the evidence that lower risk groups who could safely be screened less frequently for sight-threatening diabetic retinopathy (DR) than annually. Data have demonstrated that people with no DR in either eye are at a low risk of progression to sight-threatening DR over a 2-year period (event rate 4.8 per 1000 person years), irrespective of whether the screening method is one-field non-mydriatic or two-field mydriatic digital photography. Low risk has been defined as no retinopathy on two consecutive screening episodes or no retinopathy on one screening episode combined with risk factor data. The risk of an extension to 2 years is less than 5 per 1000 person years in a population with a national screening programme, and the general standard of diabetes care is relatively good, whether low risk is defined as no retinopathy on two consecutive screening episodes or no retinopathy on one screening episode combined with other risk factor data. The definition used in different populations is likely to depend on the availability of data.
Systemic effects of screening for retinopathy of prematurity.
Laws, D E; Morton, C; Weindling, M; Clark, D
1996-01-01
AIMS: To detect systemic complications of screening for retinopathy of prematurity (ROP), paying particular attention to the physical examination. METHODS: Oxygen saturation, pulse rate, and blood pressure were monitored before, during, and after 110 ROP screening examinations. RESULTS: Following topical mydriatics diastolic blood pressure was elevated by a mean of 6 (SD 7.2) mm Hg. Immediately after the examination there was a further rise in both systolic and diastolic pressure of 4.3 (14.5) mm Hg and 3.3 (11.6) mm Hg, respectively. Oxygen saturation and pulse rate remained stable during the control period and administration of eyedrops. Saturation fell by a median of 3% (95% confidence interval plus or minus 1.2%) after the examination while there was rise in pulse rate of 7 (SD 23.1) beats per minute. This change in pulse rate was not observed in infants on concurrent methylxanthine therapy. No infant had clinically significant changes at the end of the study. CONCLUSION: The initial changes in blood pressure may represent side effects of topical mydriatics but the later changes following the physical examination may be an additional response to the stress of ROP screening. PMID:8695564
2011-10-01
Diabetic Retinopathy Study Research Group, 1981; Early Treatment Diabetic Retinopathy Research Group, 1991). Diabetes -related vision loss is often...2001; Chow et al., 2006). For diagnosis of diabetic retinopathy and diabetic macular edema, the telehealth eye care assessments agree substantially...with mydriatic seven-standard field Early Treatment Diabetic Retinopathy Study (ETDRS) protocol photography (Bursell et al., 2001) and with dilated
Lower conjunctival fornix packing for mydriasis in premature infants: a randomized trial
Thanathanee, Onsiri; Ratanapakorn, Tanapat; Morley, Michael G; Yospaiboon, Yosanan
2012-01-01
Objective To compare the mydriatic effect of lower conjunctival fornix packing to conventional instillation of eyedrops containing 2.5% phenylephrine and 1% tropicamide in premature infants undergoing examination for retinopathy of prematurity. Methods The patients were randomized to receive either conventional instillation of mydriatic drops or lower conjunctival fornix packing in one eye and the alternate method in the fellow eye. For the eyes receiving lower conjunctival fornix packing (study group), one small piece of the cotton wool soaked with one drop of 2.5% phenylephrine and one drop of 1% tropicamide was packed in the lower conjunctival fornix for 15 minutes. For the eyes receiving the conventional instillation (control group), 2.5% phenylephrine and 1% tropicamide were alternately instilled every 5 minutes for two doses each. Horizontal pupil diameter was measured with a ruler in millimeters 40 minutes later. Results The mean dilated pupil diameter in study group and control group were 5.76 ± 1.01 mm and 4.50 ± 1.08 mm, respectively. This difference was statistically significant (P < 0.05). Conclusion The dilated pupil diameter after receiving the lower conjunctival fornix packing was larger than conventional instillation with a statistically significant difference. We recommended the packing method to dilate the preterm infant pupil, especially if the pupil is difficult to dilate. PMID:22368443
Del Hierro Zarzuelo, A; Boto de Los Bueis, A
2016-09-01
To evaluate a series of case that developed iris changes after performing Descemet's stripping automated endothelial keratoplasty (DSAEK). Retrospective study of eyes that developed iris abnormalities, such as pupil ovalisation, iris atrophy, iridocorneal synechiae, mydriatic pupil, and pigmentary changes after performing DSAEK in a tertiary hospital. In a series of the first 32 DSAEK procedures performed, new single or mixed iris alterations were observed in 12 eyes (37.5%). Iris-corneal synechiae were observed in 7 eyes, corectopias in 9 eyes, iris atrophy in 3 cases, and one case developed an areflexic mydriatic pupil. Long-term pigment dispersion at the edge of the lenticule was observed in 12 eyes. The alterations occurred after three months from the surgery. In the evaluation of the associated factors, malignant glaucoma had occurred in 1 case, 2 eyes had required a second surgery, one case by re-DSAEK, and the other one by removing the intraocular lens due to lens opacification. Two cases had a shallow anterior chamber. No relationship was found between the thickness of the peripheral lenticule and the presence of synechiae. Iris changes regarding DSAEK are possible. A discussion is presented on the relationship between increased intraocular pressure due to air in anterior chamber and its relationship with ischaemia and secondary alterations in the iris. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
2010-10-01
Requirements Application Server BEA Weblogic Express 9.2 or higher Java v5Apache Struts v2 Hibernate v2 C3PO SQL*Net client / JDBC Database Server...designed for the desktop o An HTML and JavaScript browser-based front end designed for mobile Smartphones - A Java -based framework utilizing Apache...Technology Requirements The recommended technologies are as follows: Technology Use Requirements Java Application Provides the backend application
Portable, low-priced retinal imager for eye disease screening
NASA Astrophysics Data System (ADS)
Soliz, Peter; Nemeth, Sheila; VanNess, Richard; Barriga, E. S.; Zamora, Gilberto
2014-02-01
The objective of this project was to develop and demonstrate a portable, low-priced, easy to use non-mydriatic retinal camera for eye disease screening in underserved urban and rural locations. Existing portable retinal imagers do not meet the requirements of a low-cost camera with sufficient technical capabilities (field of view, image quality, portability, battery power, and ease-of-use) to be distributed widely to low volume clinics, such as the offices of single primary care physicians serving rural communities or other economically stressed healthcare facilities. Our approach for Smart i-Rx is based primarily on a significant departure from current generations of desktop and hand-held commercial retinal cameras as well as those under development. Our techniques include: 1) Exclusive use of off-the-shelf components; 2) Integration of retinal imaging device into low-cost, high utility camera mount and chin rest; 3) Unique optical and illumination designed for small form factor; and 4) Exploitation of autofocus technology built into present digital SLR recreational cameras; and 5) Integration of a polarization technique to avoid the corneal reflex. In a prospective study, 41 out of 44 diabetics were imaged successfully. No imaging was attempted on three of the subjects due to noticeably small pupils (less than 2mm). The images were of sufficient quality to detect abnormalities related to diabetic retinopathy, such as microaneurysms and exudates. These images were compared with ones taken non-mydriatically with a Canon CR-1 Mark II camera. No cases identified as having DR by expert retinal graders were missed in the Smart i-Rx images.
Minuto, N; Emmanuele, V; Vannati, M; Russo, C; Rebora, C; Panarello, S; Pistorio, A; Lorini, R; d'Annunzio, G
2012-04-01
Diabetic retinopathy seriously impairs patients' quality of life, since it represents the first cause of blindness in industrialized countries. To estimate prevalence of retinopathy in young Type 1 diabetes patients using a non-mydriatic digital stereoscopic retinal imaging (NMDSRI), and to evaluate the impact of socio-demographic, clinical, and metabolic variables. In 247 young patients glycated hemoglobin (HbA1c), gender, age, pubertal stage, presence of diabetic ketoacidosis (DKA), HLA-DQ heterodimers of susceptibility for Type 1 diabetes, and β-cell autoimmunity at clinical onset were considered. At retinopathy screening, we evaluated age, disease duration, pubertal stage, body mass index (BMI-SDS), insulin requirement, HbA1c levels, other autoimmune diseases, diabetes-related complications, serum concentrations of cholesterol and triglycerides, systolic and diastolic blood pressure. Retinopathy was found in 26/247 patients: 25 showed background retinopathy, and 1 had a sight-threatening retinopathy. A significant relationship between retinopathy and female gender (p=0.01), duration of disease ≥15 yr (p<0.0001), serum triglycerides levels >65 mg/dl (p=0.012) and mean HbA1c ≥7.5% or >9% (p=0.0014) were found at the multivariate logistic analysis. Metabolic control is the most important modifiable factor and promotion of continuous educational process to reach a good metabolic control is a cornerstone to prevent microangiopathic complications. Symptoms appear when the complication is already established; a screening program with an early diagnosis is mandatory to prevent an irreversible damage.
Bismuth, Pierre; Bismuth, Michel; Dupouy, Julie; Rougé-Bugat, Marie-Eve; Poutrain, Jean-Christophe; Escourrou, Brigitte; Hanaire, Hélène; Oustric, Stéphane
2012-12-01
Fundus photographs using non-mydriatic digital cameras for diabetic retinopathy screening have been studied in France during the past 10 years. Nevertheless, the different screening modalities have not been compared. The main goal of this study was to compare patient recruitment with two different screening modalities, and secondarily to compare diagnostic effectiveness and cost. A retrospective study analyzed data from the Diabetes Midi Pyrenees Network in 2005 and between 2006 and 2010. In 2005, a vehicle with digital camera traveled through a rural department in order to screen diabetic patients whose last fundus examination was performed greater than 1 year previously. Between 2006 and 2010, general practitioners sent their diabetic patients whose last fundus examination was performed greater than 1 year previously to a "local" screening site. In the two cases, fundus photographs were made by trained operator at screening site and analyzed by an ophthalmologist. The "mobile" screening recruited 698 patients, and the "local" screening 345 patients. Patients recruited by "mobile" screening were older than those recruited by "local" screening. They were preferentially men and suffered from diabetes from far longer The diagnostic performance of "local" screening was 26.8%, and it was 28.6% for "mobile" screening (p = 0.47). The cost of screening was higher for "mobile" screening: 116 Euro against 61 Euro for "local" screening. "Mobile" screening could allow more patient recruitment than "local" screening when geographic and demographic constraints are more important.
Le Jeune, Caroline; Chebli, Fayçal; Leon, Lorette; Anthoine, Emmanuelle; Weber, Michel; Péchereau, Alain; Lebranchu, Pierre
2018-01-01
Abnormal torsion could be associated with cyclovertical strabismus, but torsion measurements are not reliable in children. To assess an objective fundus torsion evaluation in a paediatric population, we used Non-Mydriatic Fundus photography (NMFP) in healthy and cyclovertical strabismus patients to evaluate the disc-foveal angle over time and observers. We used a retrospective set of NMFP including 24 A or V-pattern strabismus and 27 age-matched normal children (mean age 6.4 and 6.7 years respectively), taken during 2 distinct follow-up consultations (separated by 251 and 479 days respectively). Each disc-foveal angle measurement (from which the ocular torsion can be assessed) was performed by 5 different observers, using graphical software and based on reproducible fundus anatomical marks. Statistical analysis was performed with a multivariate ANOVA using group, time and observers as factors, in addition to intraclass coefficient correlation (ICC) to assess measurement reproducibility. A significant difference of disc-foveal angle measures was observed between groups (p<0,001): 18.73° (SD = 6.42), -3,25° (SD = 5.51) and 6,89° (SD = 4,41) respectively for V-pattern, A- pattern and normal subjects. Neither observers (F = 0,2028 p = 0,9369) nor time between 1st and 2nd NMFP (F = 0,6312 p = 0,4271) seem to influence the measure of disc-foveal angle. The evaluation of disc-foveal angle was very reproducible between observers (ICC>0,97). Abnormal amount of objective torsion could be associated with alphabet-pattern strabismus. Disc-foveal angle evaluation by NMFP in a children population appears as a non-invasive, reliable and reproducible method.
Goatman, Keith; Charnley, Amanda; Webster, Laura; Nussey, Stephen
2011-01-01
To assess the performance of automated disease detection in diabetic retinopathy screening using two field mydriatic photography. Images from 8,271 sequential patient screening episodes from a South London diabetic retinopathy screening service were processed by the Medalytix iGrading™ automated grading system. For each screening episode macular-centred and disc-centred images of both eyes were acquired and independently graded according to the English national grading scheme. Where discrepancies were found between the automated result and original manual grade, internal and external arbitration was used to determine the final study grades. Two versions of the software were used: one that detected microaneurysms alone, and one that detected blot haemorrhages and exudates in addition to microaneurysms. Results for each version were calculated once using both fields and once using the macula-centred field alone. Of the 8,271 episodes, 346 (4.2%) were considered unassessable. Referable disease was detected in 587 episodes (7.1%). The sensitivity of the automated system for detecting unassessable images ranged from 97.4% to 99.1% depending on configuration. The sensitivity of the automated system for referable episodes ranged from 98.3% to 99.3%. All the episodes that included proliferative or pre-proliferative retinopathy were detected by the automated system regardless of configuration (192/192, 95% confidence interval 98.0% to 100%). If implemented as the first step in grading, the automated system would have reduced the manual grading effort by between 2,183 and 3,147 patient episodes (26.4% to 38.1%). Automated grading can safely reduce the workload of manual grading using two field, mydriatic photography in a routine screening service.
Murgatroyd, H; Ellingford, A; Cox, A; Binnie, M; Ellis, J D; MacEwen, C J; Leese, G P
2004-01-01
Aims: To assess the effects of (1) mydriasis and (2) single versus three field photography on screening for diabetic eye disease using digital photography Method: Slit lamp examination findings were compared to digital fundal photographs for the detection of any retinopathy and for referable retinopathy in 398 patients (794 eyes). A Topcon TRC-NW6S digital non-mydriatic fundus camera was used. Three photographic strategies were used: undilated single field, dilated single field, and dilated multiple fields. The photographs were presented in random order to one of two retinal screeners. For the single field photographs the screeners were masked to the use of mydriatics. In 13% of fundal photographs, grading was performed by both, rather than just one grader. Results: Mydriasis reduced the proportion of ungradable photographs from 26% to 5% (p<0.001). Neither mydriasis nor three field photography improved the sensitivity or specificity for the detection of any retinopathy or of referable retinopathy when compared with undilated single field photography. The sensitivity and specificity for detecting referable retinopathy using undilated single field photography was 77% (95% CI 71 to 84) and 95 % (95% CI 93 to 97) respectively. Using dilated single field photography the figures were 81% (95% CI 76 to 87) and 92% (95% CI 90 to 94) respectively. Using dilated three field photography the figures were 83% (95% CI 78 to 88) and 93% (95% CI 91 to 96) respectively. Intergrader reliability for the detection of referable retinopathy in gradable photographs was excellent (Kappa values 0.86–1.00). Conclusions: Mydriasis reduces the technical failure rate. Mydriasis and the three field photography as used in this study do not increase the sensitivity or specificity of detecting diabetic retinopathy. PMID:15205238
Neubauer, Aljoscha S; Rothschuh, Antje; Ulbig, Michael W; Blum, Marcus
2008-03-01
Grading diabetic retinopathy in clinical trials is frequently based on 7-field stereo photography of the fundus in diagnostic mydriasis. In terms of image quality, the FF450(plus) camera (Carl Zeiss Meditec AG, Jena, Germany) defines a high-quality reference. The aim of the study was to investigate if the fully digital fundus camera Visucam(PRO NM) could serve as an alternative in clinical trials requiring 7-field stereo photography. A total of 128 eyes of diabetes patients were enrolled in the randomized, controlled, prospective trial. Seven-field stereo photography was performed with the Visucam(PRO NM) and the FF450(plus) camera, in random order, both in diagnostic mydriasis. The resulting 256 image sets from the two camera systems were graded for retinopathy levels and image quality (on a scale of 1-5); both were anonymized and blinded to the image source. On FF450(plus) stereoscopic imaging, 20% of the patients had no or mild diabetic retinopathy (ETDRS level < or = 20) and 29% had no macular oedema. No patient had to be excluded as a result of image quality. Retinopathy level did not influence the quality of grading or of images. Excellent overall correspondence was obtained between the two fundus cameras regarding retinopathy levels (kappa 0.87) and macular oedema (kappa 0.80). In diagnostic mydriasis the image quality of the Visucam was graded slightly as better than that of the FF450(plus) (2.20 versus 2.41; p < 0.001), especially for pupils < 7 mm in mydriasis. The non-mydriatic Visucam(PRO NM) offers good image quality and is suitable as a more cost-efficient and easy-to-operate camera for applications and clinical trials requiring 7-field stereo photography.
Khan, Taskeen; Bertram, Melanie Y; Jina, Ruxana; Mash, Bob; Levitt, Naomi; Hofman, Karen
2013-08-01
South Africa like many other developing countries is experiencing an epidemiologic transition with a marked increase in the non-communicable disease (NCD) burden. Diabetic retinopathy is the most common cause of incidental blindness in adults. A screening programme using a mobile fundal camera in a primary care setting has been shown to be effective in the country. Information on affordability and cost is essential for policymakers to consider its adoption. Economic evaluation is the comparative analysis of competing alternative interventions in terms of costs and consequences. A cost effectiveness analysis was done using actual costs from the primary care screening programme. A total of 14,541 patients were screened in three primary healthcare facilities in the Western Cape. Photographs were taken by a trained technician with supervision by an ophthalmic nurse. The photographs were then read by a medical officer with ophthalmic experience. A cost effective ratio of $1206 per blindness case averted was obtained. This included costs for screening and treating an individual. The cost just to screen a patient for retinopathy was $22. The costs of screening and treating all incident cases of blindness due to diabetes in South Africa would be 168,000,000 ZAR ($19,310,344) per annum. Non mydriatic digital fundoscopy is a cost effective measure in the screening and diagnosis of diabetic retinopathy in a primary care setting in South Africa. The major savings in the long term are a result of avoiding government disability grant for people who suffer loss of vision. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Pitfalls in colour photography of choroidal tumours
Schalenbourg, A; Zografos, L
2013-01-01
Colour imaging of fundus tumours has been transformed by the development of digital and confocal scanning laser photography. These advances provide numerous benefits, such as panoramic images, increased contrast, non-contact wide-angle imaging, non-mydriatic photography, and simultaneous angiography. False tumour colour representation can, however, cause serious diagnostic errors. Large choroidal tumours can be totally invisible on angiography. Pseudogrowth can occur because of artefacts caused by different methods of fundus illumination, movement of reference blood vessels, and flattening of Bruch's membrane and sclera when tumour regression occurs. Awareness of these pitfalls should prevent the clinician from misdiagnosing tumours and wrongfully concluding that a tumour has grown. PMID:23238442
Pitfalls in colour photography of choroidal tumours.
Schalenbourg, A; Zografos, L
2013-02-01
Colour imaging of fundus tumours has been transformed by the development of digital and confocal scanning laser photography. These advances provide numerous benefits, such as panoramic images, increased contrast, non-contact wide-angle imaging, non-mydriatic photography, and simultaneous angiography. False tumour colour representation can, however, cause serious diagnostic errors. Large choroidal tumours can be totally invisible on angiography. Pseudogrowth can occur because of artefacts caused by different methods of fundus illumination, movement of reference blood vessels, and flattening of Bruch's membrane and sclera when tumour regression occurs. Awareness of these pitfalls should prevent the clinician from misdiagnosing tumours and wrongfully concluding that a tumour has grown.
Counteracting the effects of mydriatics. Does it benefit the patient?
Nelson, M E; Orton, H P
1987-04-01
The effect of 2% pilocarpine nitrate in countering mydriasis, cycloplegia, and change in visual acuity due to 0.5% tropicamide was studied in 23 healthy volunteers. There was no significant difference in the decrease in pupil size or the rate of return of accommodation between the eye that received pilocarpine and the control eye. The effect of tropicamide on visual acuity was slight. In four (17%) of 23 eyes that received pilocarpine, visual acuity was reduced to 6/36 or worse. It is suggested that the use of 2% pilocarpine in the attempted reversal of 0.5% tropicamide to improve a patient's vision is not helpful and may possibly be harmful.
Confocal retinal imaging using a digital light projector with a near infrared VCSEL source
NASA Astrophysics Data System (ADS)
Muller, Matthew S.; Elsner, Ann E.
2018-02-01
A custom near infrared VCSEL source has been implemented in a confocal non-mydriatic retinal camera, the Digital Light Ophthalmoscope (DLO). The use of near infrared light improves patient comfort, avoids pupil constriction, penetrates the deeper retina, and does not mask visual stimuli. The DLO performs confocal imaging by synchronizing a sequence of lines displayed with a digital micromirror device to the rolling shutter exposure of a 2D CMOS camera. Real-time software adjustments enable multiply scattered light imaging, which rapidly and cost-effectively emphasizes drusen and other scattering disruptions in the deeper retina. A separate 5.1" LCD display provides customizable visible stimuli for vision experiments with simultaneous near infrared imaging.
Mahon, Lewis W; Klar, Neil S; Schulz, David C; Gonder, John R; Hramiak, Irene M; Mahon, Jeffrey L
2017-01-01
Introduction Suboptimal screening for diabetic eye disease is a major cause of preventable vision loss. Screening barriers include mydriasis and the extra time patients need to attend dedicated eye screening appointments. In the Clearsight trial, we are testing whether screening by non-mydriatic ultra-wide field (NM UWF) imaging on the day patients attend their diabetes outpatient clinic visit improves detection of clinically important eye disease compared with usual screening. Methods and analysis Patients with diabetes due for a screening eye exam by the 2013 Canadian Diabetes Association (CDA) practice guidelines are being randomised to on-site screening by NM UWF imaging on the day of their clinic visit or to usual screening where, per CDA guidelines, they are encouraged to arrange an exam by an optometrist. The primary outcome is actionable eye disease (AED) based on a need for referral to ophthalmology and/or increased ocular surveillance. The primary analysis will use an intention-to-screen approach that compares the proportions of detected AED between on-site and usual screening groups under a superiority hypothesis in favour of on-site screening. With 740 randomised participants, the study will have 80% power to detect ≥5% absolute increase in the AED rate among on-site screening versus usual screening participants. This difference translates into a number-needed-to-screen by on-site screening of 20 to detect 1 additional person with AED. Ethics and dissemination The protocol was approved by the institutional review board of Western University. The findings of the trial will be disseminated directly to participants and through peer-reviewed publications and conference presentations. Trial registration number ClinicalTrials.Gov NCT02579837 (registered 16 October 2015). Protocol issue date 18 November 2015. PMID:28775182
Confocal Retinal Imaging Using a Digital Light Projector with a Near Infrared VCSEL Source
Muller, Matthew S.; Elsner, Ann E.
2018-01-01
A custom near infrared VCSEL source has been implemented in a confocal non-mydriatic retinal camera, the Digital Light Ophthalmoscope (DLO). The use of near infrared light improves patient comfort, avoids pupil constriction, penetrates the deeper retina, and does not mask visual stimuli. The DLO performs confocal imaging by synchronizing a sequence of lines displayed with a digital micromirror device to the rolling shutter exposure of a 2D CMOS camera. Real-time software adjustments enable multiply scattered light imaging, which rapidly and cost-effectively emphasizes drusen and other scattering disruptions in the deeper retina. A separate 5.1″ LCD display provides customizable visible stimuli for vision experiments with simultaneous near infrared imaging. PMID:29899586
DOE Office of Scientific and Technical Information (OSTI.GOV)
Danysz, A.; Proniewski, H.; Wisniewski, K.
< ; < > 8 ; 9 8 8 ; < ; 8 : to dogs (400 r), cats (400 r), gninea pigs (450 r), and mice (180-200 r). The course of radiation illness was estimated on the basis of leukocyte count. During radiation sickness the changes in pharmacologic action and toxicity of various drugs affecting the autonomic nervous system were investigated. By tests on the reactivity of mouse intestine in situ it was shown that at the peak of acute radiation sickness the toxicity of parasympathicotonics (pilocarpine, prostigmine), especially of acetylcholine, sympathicolytics (Priscol), and ganglioplegics (nicotine) decreased. The toxicitymore » of parasympathicolytic drugs (atropine) was higher. No changes of toxicity of sympathicotonics (adrenaline, iproniazid) were found, except for ephedrine, whose toxicity after irradiation significantly increased. Mouse intestinal motility tests showed a reduction 3--6 days postirradiation in the pharmacologic effects of parasympathicotonics (acetylcholine, prostigmine), especially of pilocarpine and ganglioplegics (nicotine, hexamethonium). At the same time the effects of sympathicotonic drugs (adrenaline, Sympatol) increased; on the contrary the monamine oxidase (MAO) inhibitor (iproniazid) showed a marked decrease in effect. With sympathicotonic drugs, pressor effects, changes of ECG, vasoconstrictive and mydriatic effects, and the contractive action on the nictitating membrane of cat were investigated. The pressor effects of adrenaline in dogs rose in the course of radiation sickness. No changes of pressor effects of noradrenaline and ephedrine were found, but the time of post-ephedrine hypertension was prolonged. In the acute stage of the illness, catecholamines evoked more significant changes in the ECG in dogs. During radiation sickness in cats, phasic changes in reactivity of the blood vessels in an isolated limb to catecholamines were observed: in the first phase, diminution; however, at the peak of the disease an increase in vasoconstrictory effects was seen. The action of iproniazid was insignificantly diminished. The mydriatic effect of catecholamines increased at the peak of radiation sickness. The reactivity of the nictitating membrane of cat did not change after smaller doses of adrenaline. In tests of parasympathicotonic drugs, the sensitivity of isolated guinea pig organs (intestine, uterus) to acetylcholine, pilocarpine, and prostigmine at the peak of radiation sickness was markedly diminished, but the sensitivity of intestinal smooth muscle to histamine remained unchanged. With parasympathicolnic drugs, an increase of mydriatic effect of atropine in irradiated mice was observed. Thus in most cases there were increased pharmacologic effects of directacting adrenergic drugs and decreased effects, but increased toxicity, of MAO inhibitors. The diminished pharmacologic effects and toxicity of parasympathicolytic drugs was also shown. The effects and toxicity of ganglioplegic drugs and toxicity of sympathicolytic drugs showed a marked decrease. The results indicrte increased susceptibility of adrenergic receptors and diminished susceptibility of cholinergic receptors on the peak of radiation sickness. It is suggested that these changes may arise from the characteristic disturbances in functional state of the vegetative nervous system, and particularly on the neurohormonal basis. To verify this, catecholamine level in the adrenals and cholinesterase activity was determined. Crtecholamine levels in the adrenals of irradiated mice varied phasically. In the first phase of radiation sickness (1--7 days) this level diminished to approximates 50% of the initial value. In the second phase it showed an increase of nearly 10 times. During radiation sickness a marked fall of acetylcholinesterase activity in the uterus, intestine, and brain of the gninea pigs was found. This supports the postulated parasympathicotonia at the peak of radiation sickness. The influence of increased acetylcholine level after prostigmine on the antiperistaltic action of adrenaline and on the toxicity« less
[Anterior uveitis caused by electrical discharge in whole body injuries (fifteen years study)].
Krásný, J; Brož, L; Kripner, J
2013-10-01
To inform about clinical analysis of early ophthalmologic complication (uveitis) in patients sustained electric discharge injury. The authors refer about fifteen years follow-up of pediatric patients at the Department of Burns Medicine, 3rd Medical Faculty, Charles University in Prague, Czech Republic, E.U., with electric discharge injury, in which the anterior uveitis was detected. Out of 43 patients after electric discharge injury, the always-unilateral iritis (iridocyclitis) was diagnosed in four (9 %) patients according to thorough going follow-up after first accidental diagnosis in the year 1998. Out of four boys aged 12 - 15 years, the first two were injured during the "play" - due to the contact with electrical trolley wire while running on railroad wagons roofs, and the two others were stuck by lighting under a tree by secondary electrical discharge. More serious skin burns were noticed in high-voltage current injury - 69 % or 55 % of body surface respectively, with the necessity of skin transplantation. The same was necessary in one boy injured by lighting with burns of 25 % of body surface, while the last one had on the skin the lighting signs only. In most of the patients, the resuscitation care due to unconsciousness and posttraumatic shock was necessary. The anterior uveitis was diagnosed subsequently, after initial preliminary diagnoses as conjunctivitis, episcleritis, or ophthalmia electrical. The iritis without visual function decrease was discovered in few days after the injury in three patients. Treatment and results: The inflammation was in these cases treated with short-term application of mydriatic and corticosteroid eye drops. Once only, the uveitis appeared after two months during the patients hospitalization and then the signs of iridocyclitis in the anterior chamber worsened and caused visual acuity decrease to hand movement in front of the eye. The condition was successfully treated by means of parabulbar betamethasone injection and long-term application of mydriatic and corticosteroid drops. Uveitis in electrical discharge injury of different origin is a rare early complication, which may be determined solely by regular ophthalmologic follow-up examinations of the patients.
Orrico, Marco; Melotti, Roberto; Mantovani, Anna; Avesani, Barbara; De Marco, Roberto; De Leo, Domenico
2008-12-01
Determination of the time since death in the early postmortem period is one of the most critical issues to be faced by criminal investigators. One of the techniques is the evaluation of the pupil pharmacological reactivity. In the present work, we aim at identifying whether an objective and single method, based on pharmacological pupil reaction, is feasible or not. Between 2002 and 2003 calendar years, we observed 309 bodies, whose eyes have been each instilled apart, within 26 hours since death, with either a myotic substance or a mydriatic solution. Our results show that the real effectiveness of pupil pharmacological reactivity as method for assessing the time since death in early postmortem period is not only questionable but even highly misleading if not replaced by alternative objective physiological tests and appropriate professional judgments by the investigators.
Motion detection and compensation in infrared retinal image sequences.
Scharcanski, J; Schardosim, L R; Santos, D; Stuchi, A
2013-01-01
Infrared image data captured by non-mydriatic digital retinography systems often are used in the diagnosis and treatment of the diabetic macular edema (DME). Infrared illumination is less aggressive to the patient retina, and retinal studies can be carried out without pupil dilation. However, sequences of infrared eye fundus images of static scenes, tend to present pixel intensity fluctuations in time, and noisy and background illumination changes pose a challenge to most motion detection methods proposed in the literature. In this paper, we present a retinal motion detection method that is adaptive to background noise and illumination changes. Our experimental results indicate that this method is suitable for detecting retinal motion in infrared image sequences, and compensate the detected motion, which is relevant in retinal laser treatment systems for DME. Copyright © 2013 Elsevier Ltd. All rights reserved.
Equine recurrent uveitis: the European viewpoint.
Spiess, B M
2010-03-01
Equine recurrent uveitis (ERU) has always been and still is an important disease with a significant impact on the horse industry in Europe, with a prevalence of 8-10%. The need to understand and manage the disease has spurred the development of veterinary ophthalmology in general, although the aetiology of the disease remains the subject of intense discussion. It is most probably an autoimmune disease triggered, at least in Europe, in the majority of cases by Leptospira spp. The therapy of ERU has evolved over the centuries from various methods of bloodletting to rational medical therapy using mydriatics and steroidal and nonsteroidal anti-inflammatory drugs, to surgical therapies, such as vitrectomy or implantation of cyclosporin-releasing devices. In Europe, pars plana vitrectomy in horses testing positive for Leptospira spp. appears to be the most successful form of therapy at the present time.
Update on the Treatment of Uveitis in Patients with Juvenile Idiopathic Arthritis: A Review.
Asproudis, Ioannis; Katsanos, Andreas; Kozeis, Nikolaos; Tantou, Alexandra; Konstas, Anastasios G
2017-12-01
Chronic uveitis is a common extra-articular manifestation of juvenile idiopathic arthritis. The classic clinical picture is one of chronic anterior uveitis, which usually remains asymptomatic until ocular complications arise. The risk of uveitis is increased in girls with an early onset of oligoarthritis and positive antinuclear antibodies. Even though the inflammation in patients with juvenile idiopathic arthritis is initially limited in the anterior part of the eye, chronic active inflammation may eventually cause significant damage to the posterior pole. Complications may include band keratopathy, cataract, secondary glaucoma, posterior synechiae, cystoid macular edema, and hypotony. The cooperation of ophthalmologists with rheumatologists may help define the best treatment plan. The ophthalmic therapeutic regimen includes topical corticosteroids and mydriatics, while in severe cases immunosuppressive and biological agents are introduced. Surgical management of complications might be needed.
Plenoptic Ophthalmoscopy: A Novel Imaging Technique.
Adam, Murtaza K; Aenchbacher, Weston; Kurzweg, Timothy; Hsu, Jason
2016-11-01
This prospective retinal imaging case series was designed to establish feasibility of plenoptic ophthalmoscopy (PO), a novel mydriatic fundus imaging technique. A custom variable intensity LED array light source adapter was created for the Lytro Gen1 light-field camera (Lytro, Mountain View, CA). Initial PO testing was performed on a model eye and rabbit fundi. PO image acquisition was then performed on dilated human subjects with a variety of retinal pathology and images were subjected to computational enhancement. The Lytro Gen1 light-field camera with custom LED array captured fundus images of eyes with diabetic retinopathy, age-related macular degeneration, retinal detachment, and other diagnoses. Post-acquisition computational processing allowed for refocusing and perspective shifting of retinal PO images, resulting in improved image quality. The application of PO to image the ocular fundus is feasible. Additional studies are needed to determine its potential clinical utility. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:1038-1043.]. Copyright 2016, SLACK Incorporated.
Digital micromirror device based ophthalmoscope with concentric circle scanning.
Damodaran, Mathi; Vienola, Kari V; Braaf, Boy; Vermeer, Koenraad A; de Boer, Johannes F
2017-05-01
Retinal imaging is demonstrated using a novel scanning light ophthalmoscope based on a digital micromirror device with 810 nm illumination. Concentric circles were used as scan patterns, which facilitated fixation by a human subject for imaging. An annular illumination was implemented in the system to reduce the background caused by corneal reflections and thereby to enhance the signal-to-noise ratio. A 1.9-fold increase in the signal-to-noise ratio was found by using an annular illumination aperture compared to a circular illumination aperture, resulting in a 5-fold increase in imaging speed and a better signal-to-noise ratio compared to our previous system. We tested the imaging performance of our system by performing non-mydriatic imaging on two subjects at a speed of 7 Hz with a maximum 20° (diameter) field of view. The images were shot noise limited and clearly show various anatomical features of the retina with high contrast.
Digital micromirror device based ophthalmoscope with concentric circle scanning
Damodaran, Mathi; Vienola, Kari V.; Braaf, Boy; Vermeer, Koenraad A.; de Boer, Johannes F.
2017-01-01
Retinal imaging is demonstrated using a novel scanning light ophthalmoscope based on a digital micromirror device with 810 nm illumination. Concentric circles were used as scan patterns, which facilitated fixation by a human subject for imaging. An annular illumination was implemented in the system to reduce the background caused by corneal reflections and thereby to enhance the signal-to-noise ratio. A 1.9-fold increase in the signal-to-noise ratio was found by using an annular illumination aperture compared to a circular illumination aperture, resulting in a 5-fold increase in imaging speed and a better signal-to-noise ratio compared to our previous system. We tested the imaging performance of our system by performing non-mydriatic imaging on two subjects at a speed of 7 Hz with a maximum 20° (diameter) field of view. The images were shot noise limited and clearly show various anatomical features of the retina with high contrast. PMID:28663905
Srinivas, Nuggehally R
2015-09-01
Tramadol is a centrally acting opioid analgesic that is prone to polymorphic metabolism via cytochrome P450 (CYP) 2D6. The generation of the active metabolite, O-desmethyltramadol, which occurs through the CYP 2D6 pathway, significantly contributes to the drug's activity. However, dosage adjustments of tramadol are typically not practiced in the clinic when treating patients who are homozygous extensive metabolizers, heterozygous extensive metabolizers, or poor metabolizers. In the event of a tramadol overdose, the consequences may be influenced importantly by the genotype or phenotype status of the subject. Depending on the individual subject's CYP 2D6 status, one may see excessive miotic-related toxicity driven by the excessive availability of O-desmethyltramadol or one may manifest mydriatic-related toxicity driven by the excessive availability of tramadol. This report provides pharmacokinetic perspectives in situations of tramadol overdosing.
Davey, Keith; Chang, Bernard; Purslow, Christine; Clay, Emilie; Vataire, Anne-Lise
2018-04-19
During cataract surgery, maintaining an adequate degree of mydriasis throughout the entire operation is critical to allow for visualisation of the capsulorhexis and the crystalline lens. Good anaesthesia is also essential for safe intraocular surgery. Mydrane® is a new injectable intracameral solution containing two mydriatics (tropicamide 0.02% and phenylephrine 0.31%) and one anaesthetic (lidocaine 1%) that was developed as an alternative to the conventional topical pre-operative mydriatics used in cataract surgery. This study aimed to estimate the budget impact across a one year time frame using Mydrane® instead of topical dilating eye drops, for a UK hospital performing 3,000 cataract operations a year. A budget impact model (BIM) was developed to compare the economic outcomes associated with the use of Mydrane® versus topical drops (tropicamide 0.5% and phenylephrine 10%) in patients undergoing cataract surgery in a UK hospital. The outcomes of interest included costs and resource use (e.g. clinician time, mydriasis failures, operating room time, number of patients per vial of therapy etc.) associated with management of mydriasis in patients undergoing cataract surgery. All model inputs considered the UK hospital perspective without social or geographical variables. Deterministic sensitivity analyses were also performed to assess the model uncertainty. Introduction of Mydrane® is associated with a cost saving of £6,251 over 3,000 cataract surgeries in one year. The acquisition costs of the Mydrane® (£18,000 by year vs. £3,330 for eye drops) were balanced by substantial reductions in mainly nurses' costs and time, plus a smaller contribution from savings in surgeons' costs (£20,511) and lower costs associated with auxiliary dilation (£410 due to avoidance of additional dilation methods). Results of the sensitivity analyses confirmed the robustness of the model to the variation of inputs. Except for the duration of one session of eye drop instillation and the cost of Mydrane®, Mydrane® achieved an incremental cost gain compared to tropicamide/phenylephrine eye drops. Despite a higher acquisition cost of Mydrane®, the budget impact of Mydrane® on hospital budgets is neutral. Mydrane® offers a promising alternative to traditional regimes using eye drops, allowing for a better patient flow and optimisation of the surgery schedule with neutral budget impact.
Chandelier Illumination for Descemet Membrane Endothelial Keratoplasty
Hayashi, Takahiko; Yuda, Kentaro; Tsuchiya, Ayako; Oyakawa, Itaru; Mizuki, Nobuhisa; Kato, Naoko
2017-01-01
Purpose: To describe a simple technique that uses posterior chandelier illumination during Descemet membrane endothelial keratoplasty in cases of severe bullous keratopathy (BK). Methods: Five eyes of 4 patients with advanced BK undergoing Descemet membrane endothelial keratoplasty were retrospectively analyzed. The pupil of the host eye was not treated with mydriatic or miotic agents. The chandelier illuminator was inserted transconjunctivally into the vitreous cavity from the pars plana. Results: In all eyes, BK was secondary to laser iridotomy, which was performed for prevention or treatment of angle closure glaucoma. The implanted graft was clearly confirmed in the anterior chamber using activated chandelier illumination. The graft was immediately attached to the host cornea, with eventual healing of BK in all eyes. No complication involving insertion or removal of the 25-gauge trocar and the chandelier illuminator was observed. No vision-threatening complication was observed in any of the 5 eyes. Conclusions: The chandelier illuminator provided good visibility of the anterior chamber and enhanced the safety of surgery by preventing formation of an inverted graft. PMID:28644235
Mucoadhesive ophthalmic vehicles: evaluation of polymeric low-viscosity formulations.
Saettone, M F; Monti, D; Torracca, M T; Chetoni, P
1994-01-01
A series of polyanionic natural or semi-synthetic polymers (polygalacturonic acid, hyaluronic acid, carboxymethylamylose, carboxymethylchitin, chondroitin sulfate, heparan sulfate and mesoglycan) were evaluated as potential mucoadhesive carriers for ophthalmic drugs. Solutions containing cyclopentolate (CY) or pilocarpine (PI) as salts (or polyanionic complexes) with the acidic polymers, all showing a low viscosity, were tested for miotic (resp. mydriatic) activity in albino rabbits. In the case of some polymeric complexes, small but significant increases of the areas under the activity vs. time curves (AUC) over reference cyclopentolate hydrochloride (CYHC1) or pilocarpine nitrate (PINO3) vehicles, and significant AUC decreases after removal of precorneal mucin by treatment with N-acetylcysteine were observed. A correlation was found between these data, considered indicative of the occurrence of a mucoadhesive interaction "in vivo", and "in vitro" viscometric data expressing the polymers-mucin force of interaction. The advantages and limitations of the mucoadhesive non-viscous approach in the formulation of ophthalmic vehicles are presented and discussed.
Shah, Sanket U; Seibles, JoAnn; Park, Susanna S
2011-01-01
This study assessed the effect of introduction of diabetic retinopathy screening using non-mydriatic digital fundus photography (nDFP) in an urban academic family practice clinic on patient compliance to recommended dilated eye examination (REE). Two hundred four patients with diabetes mellitis who were noncompliant to annual REE were screened for diabetic retinopathy using nDFP. The images were electronically transmitted to the retinal specialist to triage them for follow-up REE based on the photographic findings. Retrospective review of their medical records compared the compliance to REE before and after nDFP screening. Compliance to REE increased from 9% before screening to 66.5% after screening (P < .0001). Good quality fundus images were obtained in 93% of the eyes. Introduction of nDFP for diabetic retinopathy screening in the family practice clinic can result in a dramatic increase in compliance to REE among patients with diabetes mellitis previously poorly compliant to REE. Copyright 2011, SLACK Incorporated.
Cytomegalovirus retinitis in HIV/AIDS patients.
Chiotan, C; Radu, L; Serban, R; Cornăcel, C; Cioboata, M; Anghel, A
2014-06-15
Human immunodeficiency virus (HIV) has the ability to affect any organ in the body. In 70% of HIV-infected patients ocular manifestations were observed, which in the vast majority reflect the systemic disease and may be the first sign of a disseminated infection. The purpose of this paper is to determine the prevalence and the clinical aspects of cytomegalovirus retinitis in HIV/AIDS (Acquired Immunodeficiency Syndrome) patients. The study is retrospective, conducted in the Ophthalmology Office of "Matei Bals" Infectious Diseases Hospital in Bucharest during the period August 1, 2007 - August 1, 2013. Each patient was examined thoroughly at the slit lamp biomicroscope by using a lens of 90D and a 20D lens using the indirect microscope after administration of topical mydriatics. 131 patients were followed for HIV / AIDS with posterior segment ocular involvement. 36.64% of the 131 patients having affected the posterior segment have been diagnosed with CMV retinitis. Doctors should be aware of the existence of ocular damage in HIV/AIDS and to emphasize the importance of regular ophthalmologic examination of patients with HIV/AIDS.
Liu, Yu; Teng, Xiangyu; Zhang, Wei; Zhang, Ruifeng; Liu, Wei
2015-09-01
To evaluate the association of diabetic retinopathy with subclinical atherosclerosis in middle-aged and elderly Chinese with type 2 diabetes. A cross-sectional community-based study was performed among 1607 patients aged 40 years or older in Shanghai. Non-mydriatic digital fundus photography examination was used in diabetic retinopathy detection. Presence of elevated carotid intima-media thickness or carotid plaque was defined as subclinical atherosclerosis. The prevalence of diabetic retinopathy was 15.1% in total patients. Patients with diabetic retinopathy were more likely to have elevated carotid intima-media thickness, carotid plaque and subclinical atherosclerosis than those without diabetic retinopathy (37.9% vs 30.7%, 57.6% vs 49.6% and 64.6% vs 57.1%, respectively). The presence of diabetic retinopathy was significantly associated with increased odds of subclinical atherosclerosis (odds ratio = 1.93, 95% confidence interval = 1.03-3.60) after full adjustments. The presence of diabetic retinopathy was significantly associated with subclinical atherosclerosis in middle-aged and elderly patients with type 2 diabetics in China. © The Author(s) 2015.
Igwe, S A; Afonne, J C; Ghasi, S I
2003-06-01
Xylopia aethiopica, African guinea pepper, is an angiosperm belonging to the family Annonecae, and used mainly as spice and in traditional medicine. The ocular dynamics of bolus consumption of 300 mg total dose was undertaken on visually active volunteers with a view to finding its ocular effects or complications. Results showed that the aqueous extract of X. aethiopica was neither a miotic nor a mydriatic, but lowered the intraocular pressure (17.48%), reduced the near point of convergence (31.1%) and increased the amplitude of accommodation (8.98%) which are positively correlated (r=0.95). On the other hand, the systemic extract had no effect on the visual acuity at far and near as well as the phoria status at the appropriate distances. The convergence excess resulted in esophoria and the increased amplitude of accommodation placed greater demand on accommodation mechanism without any discomfort. The nonspecific mechanism of action makes it a safer spice which can be exploited in the management of exophoria and raised intraocular pressure (glaucoma) in instances where the efficacy of the older conventional drugs is insufficient.
Identification of the source of permanent glare from a three-piece IOL.
Wolffe, M; Landry, R J; Alpar, J J
2007-08-01
To identify the source of unwanted glare images from a three-piece intraocular lens (IOL) implant following cataract surgery. The IOL and posterior capsule were examined under mydriatic and nonmydriatic conditions using direct focal illumination from a slit lamp biomicroscope. Direct focal illumination was undertaken with both a narrow beam (0.1 mm in width) and small spot (0.1 mm in diameter) to identify the points at which the glare images were stimulated. While observing the location of the beam with the slit lamp biomicroscope, the patient indicated when the glare images were stimulated. The nasal haptic insertion into the optic was identified as the source of temporal line images arising from lights such as headlamps from oncoming cars and street lamps. The adjacent edge of the IOL was also identified as the likely source of additional cob web-like light rays. The haptic insertions in three-piece IOLs may, under certain conditions, interfere with light entering the pupil and produce extraneous images. Large mesopic pupils and decentred IOLs are conditions that increase the likelihood of unwanted glare images.
Optical design of portable nonmydriatic fundus camera
NASA Astrophysics Data System (ADS)
Chen, Weilin; Chang, Jun; Lv, Fengxian; He, Yifan; Liu, Xin; Wang, Dajiang
2016-03-01
Fundus camera is widely used in screening and diagnosis of retinal disease. It is a simple, and widely used medical equipment. Early fundus camera expands the pupil with mydriatic to increase the amount of the incoming light, which makes the patients feel vertigo and blurred. Nonmydriatic fundus camera is a trend of fundus camera. Desktop fundus camera is not easy to carry, and only suitable to be used in the hospital. However, portable nonmydriatic retinal camera is convenient for patient self-examination or medical stuff visiting a patient at home. This paper presents a portable nonmydriatic fundus camera with the field of view (FOV) of 40°, Two kinds of light source are used, 590nm is used in imaging, while 808nm light is used in observing the fundus in high resolving power. Ring lights and a hollow mirror are employed to restrain the stray light from the cornea center. The focus of the camera is adjusted by reposition the CCD along the optical axis. The range of the diopter is between -20m-1 and 20m-1.
NASA Astrophysics Data System (ADS)
de Carvalho, Luis Alberto V.; Carvalho, Valeria
2014-02-01
One of the main problems with glaucoma throughout the world is that there are typically no symptoms in the early stages. Many people who have the disease do not know they have it and by the time one finds out, the disease is usually in an advanced stage. Most retinal cameras available in the market today use sophisticated optics and have several other features/capabilities (wide-angle optics, red-free and angiography filters, etc) that make them expensive for the general practice or for screening purposes. Therefore, it is important to develop instrumentation that is fast, effective and economic, in order to reach the mass public in the general eye-care centers. In this work, we have constructed the hardware and software of a cost-effective and non-mydriatic prototype device that allows fast capturing and plotting of high-resolution quantitative 3D images and videos of the optical disc head and neighboring region (30° of field of view). The main application of this device is for glaucoma screening, although it may also be useful for the diagnosis of other pathologies related to the optic nerve.
Non-mydriatic, wide field, fundus video camera
NASA Astrophysics Data System (ADS)
Hoeher, Bernhard; Voigtmann, Peter; Michelson, Georg; Schmauss, Bernhard
2014-02-01
We describe a method we call "stripe field imaging" that is capable of capturing wide field color fundus videos and images of the human eye at pupil sizes of 2mm. This means that it can be used with a non-dilated pupil even with bright ambient light. We realized a mobile demonstrator to prove the method and we could acquire color fundus videos of subjects successfully. We designed the demonstrator as a low-cost device consisting of mass market components to show that there is no major additional technical outlay to realize the improvements we propose. The technical core idea of our method is breaking the rotational symmetry in the optical design that is given in many conventional fundus cameras. By this measure we could extend the possible field of view (FOV) at a pupil size of 2mm from a circular field with 20° in diameter to a square field with 68° by 18° in size. We acquired a fundus video while the subject was slightly touching and releasing the lid. The resulting video showed changes at vessels in the region of the papilla and a change of the paleness of the papilla.
Vandamme, Th F; Brobeck, L
2005-01-20
The purpose of this study was to determine the influence of a controlled incremental increase in size, molecular weight and number of amine, carboxylate and hydroxyl surface groups in several series of poly(amidoamine) (PAMAM) dendrimers for controlled ocular drug delivery. The duration of residence time was evaluated after solubilization of several series of PAMAM dendrimers (generations 1.5 and 2-3.5 and 4) in buffered phosphate solutions containing 2 per thousand (w/v) of fluorescein. The New Zealand albino rabbit was used as an in vivo model for qualitative and quantitative assessment of ocular tolerance and retention time after a single application of 25 microl of dendrimer solution to the eye. The same model was also used to determine the prolonged miotic or mydriatic activities of dendrimer solutions, some containing pilocarpine nitrate and some tropicamide, respectively. Residence time was longer for the solutions containing dendrimers with carboxylic and hydroxyl surface groups. No prolongation of remanence time was observed when dendrimer concentration (0.25-2%) increased. The remanence time of PAMAM dendrimer solutions on the cornea showed size and molecular weight dependency. This study allowed novel macromolecular carriers to be designed with prolonged drug residence time for the ophthalmic route.
Acute encephalopathy due to angel's trumpet intoxication: A case report and literature review.
Takeshima, Shinichi; Neshige, Shuichiro; Hara, Naoyuki; Kubo, Tomoshi; Himeno, Takahiro; Kuriyama, Masaru
2017-05-27
We report two cases (a married couple) of intoxication due to angel's trumpet ingestion. Case 1: A 71-year-old woman was found lying unconscious on the sofa at home and was brought to our hospital by ambulance. She showed mydriatic anisocoria, and an intracerebral lesion was suspected. However, the brain magnetic resonance imaging showed no abnormal lesion and acute encephalopathy of unknown cause was diagnosed. Case 2: A 68-year-old man (husband of the patient of Case 1) showed alteration of consciousness with agitation and was admitted to our hospital on the next day. He also had slight mydriasis. As his manifestations were similar to those of his wife, we studied their medical history again. We found that they mistook the roots of angel's trumpet for burdock and cooked and ate them. This intoxication causes characteristic encephalopathy with altered consciousness and mydriasis. In the case of anisocoria or mild mydriasis, the diagnosis is difficult sometimes. The intoxication occurred within a family; this was a clue to the correct diagnosis. Severe cases exhibit pyramidal signs and symptoms or convulsion, and deaths have been reported. Angel's trumpet intoxication is an important neurological emergency.
Kanjee, Raageen; Dookeran, Ravi I; Mathen, Mathen K; Stockl, Frank A; Leicht, Richard
2017-11-01
The purpose of this study was to evaluate the diabetic retinopathy (DR) tele-ophthalmology screening program in Manitoba to determine prevalence and incidence of DR, as well as to estimate the program's cost-effectiveness. Retrospective chart review. A total of 4676 patients with type 2 diabetes examined 9334 times from 2007 to 2013. Focused ophthalmic histories were recorded and examinations were performed by trained nurses, including visual acuities, intraocular pressure, and mydriatic 7 standard field stereoscopic fundus photography. Images were evaluated by retinal specialists according to the Early Treatment of Diabetic Retinopathy Study criteria. DR prevalence and incidence were then calculated during the study period. Cost-effectiveness was estimated by comparing the cost of running the tele-ophthalmology program compared with the cost of screening the same volume of patients in-office. The average prevalence of any DR in each year was 25.1%. The cumulative incidence of DR across 6 years was 17.1% (95% CI, 15.4%-18.7%). The average savings per tele-ophthalmology examination was $1007. DR is highly prevalent among the studied population. Tele-ophthalmology provides a cost-effective means of monitoring patients as well as identifying new or treatable disease. Copyright © 2017. Published by Elsevier Inc.
Baine, Katherine; Hendrix, Diane V H; Kuhn, Sonia E; Souza, Marcy J; Jones, Michael P
2016-03-01
The efficacy and safety of topically applied rocuronium in Hispaniolan Amazon parrots ( Amazona ventralis ) was assessed in a group of 10 adult birds. A complete ophthalmic examination (including Schirmer tear test, ocular reflexes, applanation tonometry, fluorescein staining, and slit-lamp biomicroscopy) was performed, and rocuronium bromide (0.15 mg in both eyes) was administered. Pupillary light reflex (PLR) and pupillary diameter were recorded in a darkened room at the following time points: 0, 10, 20, 30, 40, 50, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 300, and 360 minutes, and 24 hours. Fluorescein staining in both eyes was performed at 24 hours. By 10 minutes, PLR was absent in all birds (at 5 minutes, 8 birds; at 10 minutes, remaining 2 birds). Pupil diameter differed significantly from baseline at all time points. Additionally, PLR was decreased in 7/10 birds at 360 minutes and normal in all birds at 24 hours. Superficial corneal ulceration was observed at 24 hours in the left eye of 2/10 of the birds after fluorescein stain application. This study demonstrated that rocuronium bromide was an effective mydriatic agent in Hispaniolan Amazon parrots with rapid onset and prolonged duration of action.
[Clinical aspects and therapy of the posner-schlossmann-syndrom (author's transl)].
Hollwich, F
1978-05-01
Difficulties in the early diagnosis of the Posner-Schlossmann syndrome can be avoided by looking for the following typical clinical signs: Very fine, unpigmented precipitates, which are often only signly present, and which are scattered over the entire cornea: bright white in incident light, translucent in reflected light, and in transmitted light dark in spots. Posterior synechiae are not present. Obvious differences in color or heterochromia are present in only 30-40% of the cases. In the remaining cases, there ist only a slight color difference or unilateral, diffusely trophic hypochromia of the iris, often only after several attacks. The chamber angle is and remains open during the attacks. There are similarities between glaucomatocyclitic crisis and heterochromic cyclitis: Unilaterality, the same specific precipitates, no synechiae, and practically the same percentage of color differences of the iris. Hypochromic dystrophy of the iris dependent on the magnitude and duration of the cyclitic process. In both cases, there is the same rate of physical changes, pointing to a congenital damage of the sympathetic nervous system (status dysraphicus Passow). Hence, the Posner-Schlossmann syndrome can be regarded as a special case of heterochromic cyclitis. Neither miotics nor mydriatics, nor operation during the crisis. Acetazolamide (Diamox) combined with local cortisone will stop the crisis.
Digital retinal imaging in a residency-based patient-centered medical home.
Newman, Robert; Cummings, Doyle M; Doherty, Lisa; Patel, Nick R
2012-03-01
Diabetic retinopathy is the leading cause of blindness in adults in the United States, and early screening/treatment may preserve vision. This study examined the feasibility of using non-mydriatic digital retinal imaging (DRI) for retinopathy screening in a busy family medicine residency program at the point of care using a nurse-driven protocol. We compared the number of diabetics screened during a 1-year period before and after DRI protocol implementation. We also determined the prevalence of retinopathy, assessed patient satisfaction with the alternative screening process, and tracked ophthalmologic appointment compliance for patients referred because of abnormal screening results. Screening approximately doubled from 161 patients/year before the protocol to 330 patients/year after protocol implementation. However, DRI screening had no impact on ophthalmologic appointment compliance; only 58% of 153 patients referred for ophthalmologic evaluation because of positive screening findings completed their referral appointment. Seven cases needing urgent ophthalmologic treatment were identified. Satisfaction with primary care retinopathy screening was high. Use of a nurse-driven protocol for digital retinal imaging at the point of care dramatically improves rates of annual retinopathy screening in academic family medicine practice and can identify patients who require subspecialty referral. However, DRI screening does not improve visit compliance rates with ophthalmologists for evaluation and management.
Klein, Thomas; Wieser, Wolfgang; Reznicek, Lukas; Neubauer, Aljoscha; Kampik, Anselm; Huber, Robert
2013-01-01
We analyze the benefits and problems of in vivo optical coherence tomography (OCT) imaging of the human retina at A-scan rates in excess of 1 MHz, using a 1050 nm Fourier-domain mode-locked (FDML) laser. Different scanning strategies enabled by MHz OCT line rates are investigated, and a simple multi-volume data processing approach is presented. In-vivo OCT of the human ocular fundus is performed at different axial scan rates of up to 6.7 MHz. High quality non-mydriatic retinal imaging over an ultra-wide field is achieved by a combination of several key improvements compared to previous setups. For the FDML laser, long coherence lengths and 72 nm wavelength tuning range are achieved using a chirped fiber Bragg grating in a laser cavity at 419.1 kHz fundamental tuning rate. Very large data sets can be acquired with sustained data transfer from the data acquisition card to host computer memory, enabling high-quality averaging of many frames and of multiple aligned data sets. Three imaging modes are investigated: Alignment and averaging of 24 data sets at 1.68 MHz axial line rate, ultra-dense transverse sampling at 3.35 MHz line rate, and dual-beam imaging with two laser spots on the retina at an effective line rate of 6.7 MHz.
Pokupec, Rajko; Mrazovac, Danijela; Popović-Suić, Smiljka; Mrazovac, Visnja; Kordić, Rajko; Petricek, Igor
2013-04-01
Early detection of a refractive error and its correction are extremely important for the prevention of amblyopia (poor vision). The golden standard in the detection of refractive errors is retinoscopy--a method where the pupils are dilated in order to exclude accomodation. This results in a more accurate measurement of a refractive error. Automatic computer refractometer is also in use. The study included 30 patients, 15 boys, 15 girls aged 4-16. The first examination was conducted with refractometer on narrow pupils. Retinoscopy, followed by another examination with refractometer was performed on pupils dilated with mydriatic drops administered 3 times. The results obtained with three methods were compared. They indicate that in narrow pupils the autorefractometer revealed an increased diopter value in nearsightedness (myopia), the minus overcorrection, whereas findings obtained with retinoscopy and autorefractometer in mydriasis cycloplegia, were much more accurate. The results were statistically processed, which confirmed the differences between obtained measurements. These findings are consistent with the results of studies conducted by other authors. Automatic refractometry on narrow pupils has proven to be a method for detection of refractive errors in children. However, the exact value of the refractive error is obtained only in mydriasis--with retinoscopy or an automatic refractometer on dilated pupils.
Sarkar, Saumya; Mondal, Kanchan Kumar; Roy, Sukalyan Saha; Gayen, Sharmistha; Ghosh, Abhishek; De, Radha Raman
2015-01-01
This study compared the effectiveness of prophylactic administration of topical flurbiprofen 0.03% and nepafenac 0.1% in maintaining mydriasis during small incision cataract surgery (SICS). This study was a prospective, randomized, double-blind comparative study in adult cataract patients given topical flurbiprofen or nepafenac prior to SICS and capsular bag intraocular lens (IOL) implantation at a tertiary care hospital. Horizontal and vertical diameters of pupil were measured at the beginning and end of surgery, and the mean values were compared across the two groups. Unpaired t-test and Fisher's exact test were used to analyse the results. A total of 70 eyes of cataract surgery patients, 33 males and 37 females, with a mean age of 58.5 ± 11.24 years, were included in the study. The mean horizontal and vertical diameters of the two groups were similar at the start of surgery. Significant differences were seen after IOL implantation, with the nepafenac group having the larger mean diameters in both horizontal (P = 0.03) and vertical (P = 0.04) pupillary measurements. Topical nepafenac has been shown to be a more effective inhibitor of meiosis during SICS and provides a more stable mydriatic effect compared to topical flurbiprofen.
Klein, Thomas; Wieser, Wolfgang; Reznicek, Lukas; Neubauer, Aljoscha; Kampik, Anselm; Huber, Robert
2013-01-01
We analyze the benefits and problems of in vivo optical coherence tomography (OCT) imaging of the human retina at A-scan rates in excess of 1 MHz, using a 1050 nm Fourier-domain mode-locked (FDML) laser. Different scanning strategies enabled by MHz OCT line rates are investigated, and a simple multi-volume data processing approach is presented. In-vivo OCT of the human ocular fundus is performed at different axial scan rates of up to 6.7 MHz. High quality non-mydriatic retinal imaging over an ultra-wide field is achieved by a combination of several key improvements compared to previous setups. For the FDML laser, long coherence lengths and 72 nm wavelength tuning range are achieved using a chirped fiber Bragg grating in a laser cavity at 419.1 kHz fundamental tuning rate. Very large data sets can be acquired with sustained data transfer from the data acquisition card to host computer memory, enabling high-quality averaging of many frames and of multiple aligned data sets. Three imaging modes are investigated: Alignment and averaging of 24 data sets at 1.68 MHz axial line rate, ultra-dense transverse sampling at 3.35 MHz line rate, and dual-beam imaging with two laser spots on the retina at an effective line rate of 6.7 MHz. PMID:24156052
Keel, Stuart; Lee, Pei Ying; Scheetz, Jane; Li, Zhixi; Kotowicz, Mark A; MacIsaac, Richard J; He, Mingguang
2018-03-12
The purpose of this study is to evaluate the feasibility and patient acceptability of a novel artificial intelligence (AI)-based diabetic retinopathy (DR) screening model within endocrinology outpatient settings. Adults with diabetes were recruited from two urban endocrinology outpatient clinics and single-field, non-mydriatic fundus photographs were taken and graded for referable DR ( ≥ pre-proliferative DR). Each participant underwent; (1) automated screening model; where a deep learning algorithm (DLA) provided real-time reporting of results; and (2) manual model where retinal images were transferred to a retinal grading centre and manual grading outcomes were distributed to the patient within 2 weeks of assessment. Participants completed a questionnaire on the day of examination and 1-month following assessment to determine overall satisfaction and the preferred model of care. In total, 96 participants were screened for DR and the mean assessment time for automated screening was 6.9 minutes. Ninety-six percent of participants reported that they were either satisfied or very satisfied with the automated screening model and 78% reported that they preferred the automated model over manual. The sensitivity and specificity of the DLA for correct referral was 92.3% and 93.7%, respectively. AI-based DR screening in endocrinology outpatient settings appears to be feasible and well accepted by patients.
Kolomeyer, Anton M; Baumrind, Benjamin R; Szirth, Bernard C; Shahid, Khadija; Khouri, Albert S
2013-06-01
We investigated the use of fundus autofluorescence (FAF) imaging in screening the eyes of patients with diabetes. Images were obtained from 50 patients with type 2 diabetes undergoing telemedicine screening with colour fundus imaging. The colour and FAF images were obtained with a 15.1 megapixel non-mydriatic retinal camera. Colour and FAF images were compared for pathology seen in nonproliferative and proliferative diabetic retinopathy (NPDR and PDR, respectively). A qualitative assessment was made of the ease of detecting early retinopathy changes and the extent of existing retinopathy. The mean age of the patients was 47 years, most were male (82%) and most were African American (68%). Their mean visual acuity was 20/45 and their mean intraocular pressure was 14.3 mm Hg. Thirty-eight eyes (76%) did not show any diabetic retinopathy changes on colour or FAF imaging. Seven patients (14%) met the criteria for NPDR and five (10%) for severe NPDR or PDR. The most common findings were microaneurysms, hard exudates and intra-retinal haemorrhages (IRH) (n = 6 for each). IRH, microaneurysms and chorioretinal scars were more easily visible on FAF images. Hard exudates, pre-retinal haemorrhage and fibrosis, macular oedema and Hollenhorst plaque were easier to identify on colour photographs. The value of FAF imaging as a complementary technique to colour fundus imaging in detecting diabetic retinopathy during ocular screening warrants further investigation.
Neurophysiological intraoperative monitoring during an optic nerve schwannoma removal.
San-Juan, Daniel; Escanio Cortés, Manuel; Tena-Suck, Martha; Orozco Garduño, Adolfo Josué; López Pizano, Jesús Alejandro; Villanueva Domínguez, Jonathan; Fernández Gónzalez-Aragón, Maricarmen; Gómez-Amador, Juan Luis
2017-10-01
This paper reports the case of a patient with optic nerve schwannoma and the first use of neurophysiological intraoperative monitoring of visual evoked potentials during the removal of such tumor with no postoperative visual damage. Schwannomas are benign neoplasms of the peripheral nervous system arising from the neural crest-derived Schwann cells, these tumors are rarely located in the optic nerve and the treatment consists on surgical removal leading to high risk of damage to the visual pathway. Case report of a thirty-year-old woman with an optic nerve schwannoma. The patient underwent surgery for tumor removal on the left optic nerve through a left orbitozygomatic approach with intraoperative monitoring of left II and III cranial nerves. We used Nicolet Endeavour CR IOM (Carefusion, Middleton WI, USA) to performed visual evoked potentials stimulating binocularly with LED flash goggles with the patient´s eyes closed and direct epidural optic nerve stimulation delivering rostral to the tumor a rectangular current pulse. At follow up examinations 7 months later, the left eye visual acuity was 20/60; Ishihara score was 8/8 in both eyes; the right eye photomotor reflex was normal and left eye was mydriatic and arreflectic; optokinetic reflex and ocular conjugate movements were normal. In this case, the epidural direct electrical stimulation of optic nerve provided stable waveforms during optic nerve schwannoma resection without visual loss.
Determining degree of optic nerve edema from color fundus photography
NASA Astrophysics Data System (ADS)
Agne, Jason; Wang, Jui-Kai; Kardon, Randy H.; Garvin, Mona K.
2015-03-01
Swelling of the optic nerve head (ONH) is subjectively assessed by clinicians using the Frisén scale. It is believed that a direct measurement of the ONH volume would serve as a better representation of the swelling. However, a direct measurement requires optic nerve imaging with spectral domain optical coherence tomography (SD-OCT) and 3D segmentation of the resulting images, which is not always available during clinical evaluation. Furthermore, telemedical imaging of the eye at remote locations is more feasible with non-mydriatic fundus cameras which are less costly than OCT imagers. Therefore, there is a critical need to develop a more quantitative analysis of optic nerve swelling on a continuous scale, similar to SD-OCT. Here, we select features from more commonly available 2D fundus images and use them to predict ONH volume. Twenty-six features were extracted from each of 48 color fundus images. The features include attributes of the blood vessels, optic nerve head, and peripapillary retina areas. These features were used in a regression analysis to predict ONH volume, as computed by a segmentation of the SD-OCT image. The results of the regression analysis yielded a mean square error of 2.43 mm3 and a correlation coefficient between computed and predicted volumes of R = 0:771, which suggests that ONH volume may be predicted from fundus features alone.
Comprehensive eye evaluation algorithm
NASA Astrophysics Data System (ADS)
Agurto, C.; Nemeth, S.; Zamora, G.; Vahtel, M.; Soliz, P.; Barriga, S.
2016-03-01
In recent years, several research groups have developed automatic algorithms to detect diabetic retinopathy (DR) in individuals with diabetes (DM), using digital retinal images. Studies have indicated that diabetics have 1.5 times the annual risk of developing primary open angle glaucoma (POAG) as do people without DM. Moreover, DM patients have 1.8 times the risk for age-related macular degeneration (AMD). Although numerous investigators are developing automatic DR detection algorithms, there have been few successful efforts to create an automatic algorithm that can detect other ocular diseases, such as POAG and AMD. Consequently, our aim in the current study was to develop a comprehensive eye evaluation algorithm that not only detects DR in retinal images, but also automatically identifies glaucoma suspects and AMD by integrating other personal medical information with the retinal features. The proposed system is fully automatic and provides the likelihood of each of the three eye disease. The system was evaluated in two datasets of 104 and 88 diabetic cases. For each eye, we used two non-mydriatic digital color fundus photographs (macula and optic disc centered) and, when available, information about age, duration of diabetes, cataracts, hypertension, gender, and laboratory data. Our results show that the combination of multimodal features can increase the AUC by up to 5%, 7%, and 8% in the detection of AMD, DR, and glaucoma respectively. Marked improvement was achieved when laboratory results were combined with retinal image features.
Memon, Salah; Ahsan, Shahid; Alvi, Rashid; Fawwad, Asher; Basit, Abdul; Shera, Samad; Sheikh, Sikander Ali; Fahim, Muhammad Faisal
2015-10-01
To determine the acceptance of retinal screening, Laser uptake and subsequent follow-up in diabetic patients attending the Diabetes Centre of Diabetic Association of Pakistan (DAP), Karachi. Observational case series. Diabetic Centre of Diabetic Association of Pakistan (DAP), Karachi, from January 2011 to December 2012. All the diabetic patients were screened for Diabetic Retinopathy (DR) with non-Mydriatic Fundus Camera (NMFC). Patients with DR were examined by the ophthalmologist using fundus lens and slit lamp. DR was graded for severity on the basis of modified Airlie House Classification. Patients with Sight Threatening Diabetic Retinopathy (STDR) were advised Laser treatment. Each patient was followed-up for at least 6 months. The records of patients recommended Laser were retrieved, and called for re-examination. Retinal screening was accepted by all of the 8368 registered diabetics attending DAP Centre. On fundus photography, 21.2% (1777) individuals were found to have DR. Seven hundred and five (39.5%) patients were found to have STDR. Laser was advised to 96.4% (680) of STDR patients; amongst whom 70.5% (480) accepted Laser treatment. Out of 480 patients who had Laser treatment, 21.2% (107) turned out for follow-up after 6 months. Acceptance of retinal screening and Laser application was good; but follow-up was suboptional.
Sbaraglia, Fabio; Mores, Nadia; Garra, Rossella; Giuratrabocchetta, Giuseppe; Lepore, Domenico; Molle, Fernando; Savino, Gustavo; Piastra, Marco; Pulitano', Silvia; Sammartino, Maria
2014-04-01
Phenylephrine eye drops are widely used as mydriatic agent to reach the posterior segment of the eye. In literature, many reports suggest a systemic absorption of this agent as a source of severe adverse drug reactions. Hence, we reviewed our experience with topical phenylephrine in ophthalmic surgery. In May 2006, following US guidelines publication, a standard operating procedure was issued in our operating rooms to standardize the use of phenylephrine eye drops in our practice. Two years later, after the occurrence of a cluster of serious adverse drug reactions in infants undergoing surgery, a review of phenylephrine safety and systemic complications incidence was performed. We observed 451 pediatric patients, and 187 met the inclusions criteria: Among them, 4 experienced hemodynamic complications due to phenylephrine eye drops. The incidence of major complications was 2.1%. Two different patterns of side effects occurred. The first one was a cardiovascular derangement with severe hypertension and heart rate alterations; the other one involved exclusively pulmonary circuit causing early edema. These clinical manifestations, their duration, and treatment responses are all explainable by alfa1-adrenergic action of phenylephrine. This hypothetic pathogenesis has been confirmed also by the usefulness of direct vasodilators (anesthetic agents) and by the negative outcome occurred in the past with the use of beta-blockers. © 2013 John Wiley & Sons Ltd.
[Outdoor activity and myopia among 681 primary students in urban and rural regions of Beijing].
Guo, Yin; Liu, Lijuan; Xu, Liang; Lü, Yanyun; Tang, Ping; Feng, Yi
2014-01-21
To explore the association between outdoor activity and myopia among 681 primary students from Beijing. School-based, cross-sectional investigation. Eye examination includes the visual acuity test, auto-refractor, slit lamp, ocular biometry and non-mydriatic fundus camera. Questionnaire includes regular items, near work, outdoor activity and social-economic status. The mean time spent outdoors was 1.6 ± 0.8 hours daily. Time spent on outdoor sports and outdoor leisure were 0.7 ± 0.1 hours daily, 1.0 ± 0.8 hours daily, respectively. Mean time of outdoor activity in urban was 1.1 ± 0.4 hours daily, compared with 2.2 ± 0.8 hours daily in rural (P = 0.000). In grade-1, total time spent outdoors is significantly different between myopia and non-myopia (1.4 ± 0.6 vs 1.8 ± 0.8 hours daily, P = 0.000), similar to outdoor leisure (0.8 ± 0.6 vs 1.1 ± 0.9 hours daily, P = 0.000). The same trend was also found in grade-4. The mean time spent outdoors was 1.6 ± 0.8 hours daily. Myopia spent a lower outdoor activity compared with non-myopia. More outdoor activity, e.g., in schools, may potentially be helpful to reduce the high prevalence of myopia in the young generation.
Lightless cataract surgery using a near-infrared operating microscope.
Kim, Bong-Hyun
2006-10-01
To describe the near-infrared (NIR) operating microscopy (NIOM) system using the NIR wavelength as the illumination source and to evaluate the feasibility of this system for lightless cataract surgery. HenAm Kim Eye Center, Haenam-Gun, South Korea. In this noncomparative interventional case series, cataract surgery was performed in 4 patients with bilateral cataract using the NIOM system in 1 eye and conventional microscopy in the fellow eye. The primary components of the system include an optical filter, a stereoscopic camera, head-mounted displays, and a recording system. This system uses invisible NIR (wavelength 850 to 1300 nm) illumination to facilitate cataract surgery without light. The differences between the NIOM system and conventional microscopy during cataract surgery were evaluated. The NIOM system provided excellent 3-dimensional viewing in real time. The image resolution was sufficient while performing all steps of cataract surgery. Immediately postoperatively and at 10 and 30 minutes and 1 hour, the visual acuity was better in the 4 eyes in which the NIOM system was used than in the 4 eyes in which conventional microscopy was used. However, using the NIOM system required good surgical skill. Lightless cataract surgery using the NIOM system seems useful for obtaining good visual acuity immediately postoperatively. The system may also reduce the incidence of light-induced retinal toxicity and the need for mydriatic administration and be a good educational tool.
Textureless Macula Swelling Detection with Multiple Retinal Fundus Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giancardo, Luca; Meriaudeau, Fabrice; Karnowski, Thomas Paul
2010-01-01
Retinal fundus images acquired with non-mydriatic digital fundus cameras are a versatile tool for the diagnosis of various retinal diseases. Because of the ease of use of newer camera models and their relatively low cost, these cameras can be employed by operators with limited training for telemedicine or Point-of-Care applications. We propose a novel technique that uses uncalibrated multiple-view fundus images to analyse the swelling of the macula. This innovation enables the detection and quantitative measurement of swollen areas by remote ophthalmologists. This capability is not available with a single image and prone to error with stereo fundus cameras. Wemore » also present automatic algorithms to measure features from the reconstructed image which are useful in Point-of-Care automated diagnosis of early macular edema, e.g., before the appearance of exudation. The technique presented is divided into three parts: first, a preprocessing technique simultaneously enhances the dark microstructures of the macula and equalises the image; second, all available views are registered using non-morphological sparse features; finally, a dense pyramidal optical flow is calculated for all the images and statistically combined to build a naiveheight- map of the macula. Results are presented on three sets of synthetic images and two sets of real world images. These preliminary tests show the ability to infer a minimum swelling of 300 microns and to correlate the reconstruction with the swollen location.« less
Comparison of the effects of moclobemide and selegiline on tyramine-evoked mydriasis in man
Bitsios, P; Langley, R W; Tavernor, S; Pyykkö, K; Scheinin, M; Szabadi, E; Bradshaw, C M
1998-01-01
Aims To examine the feasibility of using the human iris in vivo for the assessment of the interaction between tyramine and monoamine oxidase (MAO) inhibitors. To examine the relative roles of the two forms of MAO in terminating the response to sympathomimetic amines in the iris, by comparing the effects of single oral doses of moclobemide, a selective MAO-A inhibitor, and selegiline, a selective MAO-B inhibitor, on mydriatic responses to tyramine. Methods Twelve healthy male volunteers participated in three monthly sessions, each associated with ingestion of one capsule (moclobemide 450 mg, selegiline 10 mg, or placebo), according to a double-blind, balanced, cross-over design. Tyramine hydrochloride eye-drops (75 mm, 2×10 μl) were instilled three times in the left conjuctival sac at 40 min intervals. Pupil diameter was monitored with a binocular infrared television pupillometer before and for 4.5 h after ingestion of the capsule. The pupillary response to tyramine was expressed as the area under the pupil diameter×time curve (arbitrary units). A blood sample was taken before and 2 h after ingestion of the capsule, for the assay of platelet MAO-B activity, and plasma 3,4-dihydroxyphenylglycol (DHPG) concentration, an index of MAO-A activity. Platelet MAO activity was assayed radiochemically, using [14C]-phenylethylamine as substrate, and plasma DHPG by high performance liquid chromatography (h.p.l.c.). The results were analysed using analysis of variance with repeated measures, followed by Bonferroni's corrected t-test, using a significance criterion of P < 0.05. Results Both moclobemide and selegiline, compared with placebo, caused significant miosis in the right (untreated) eye. The changes in pupil diameter (mm±s.e. mean) from the pretreatment measurement were: placebo −0.09±0.07, moclobemide −0.52±0.09, selegiline −0.26±0.1. The mydriatic response to tyramine was potentiated by moclobemide, compared with the response recorded in the presence of placebo. The responses to tyramine (arbitrary units±s.e. mean) were: placebo 77.08±11.65, moclobemide 140.25±18.9, selegiline 72.75±12.35. Both moclobemide and selegiline significantly reduced platelet MAO activity, compared with placebo. The changes in platelet MAO activity (nmol h−1 mg−1 protein±s.e. mean) from the pretreatment level were: placebo 0.5±0.62, moclobemide −6.7±0.66, selegiline −17.7±0.87. Moclobemide significantly reduced plasma DHPG concentration, compared with placebo. The changes in plasma DHPG concentration (nmol l−1±s.e. mean) from the pretreatment level were: placebo −0.01±0.24, moclobemide −4.98±0.32, selegiline −0.51±0.26. Conclusions The potentiation of tyramine-evoked mydriasis by moclobemide is likely to reflect the inhibition of MAO-A activity in the iris, consistent with the activity of this enzyme in sympathetic nerve terminals. The lack of effect of selegiline on tyramine-evoked mydriasis argues against a role of MAO-B in terminating the effects of sympathomimetic amines in the iris. The effects of the two drugs on platelet MAO activity and plasma DHPG concentration are in agreement with previous reports and consistent with the relative selectivity of moclobemide for MAO-A and of selegiline for MAO-B. The miosis caused by the two MAO inhibitors is likely to be due to a central sympatholytic action of the drugs. PMID:9663810
Non-mydriatic video ophthalmoscope to measure fast temporal changes of the human retina
NASA Astrophysics Data System (ADS)
Tornow, Ralf P.; Kolář, Radim; Odstrčilík, Jan
2015-07-01
The analysis of fast temporal changes of the human retina can be used to get insight to normal physiological behavior and to detect pathological deviations. This can be important for the early detection of glaucoma and other eye diseases. We developed a small, lightweight, USB powered video ophthalmoscope that allows taking video sequences of the human retina with at least 25 frames per second without dilating the pupil. Short sequences (about 10 s) of the optic nerve head (20° x 15°) are recorded from subjects and registered offline using two-stage process (phase correlation and Lucas-Kanade approach) to compensate for eye movements. From registered video sequences, different parameters can be calculated. Two applications are described here: measurement of (i) cardiac cycle induced pulsatile reflection changes and (ii) eye movements and fixation pattern. Cardiac cycle induced pulsatile reflection changes are caused by changing blood volume in the retina. Waveform and pulse parameters like amplitude and rise time can be measured in any selected areas within the retinal image. Fixation pattern ΔY(ΔX) can be assessed from eye movements during video acquisition. The eye movements ΔX[t], ΔY[t] are derived from image registration results with high temporal (40 ms) and spatial (1,86 arcmin) resolution. Parameters of pulsatile reflection changes and fixation pattern can be affected in beginning glaucoma and the method described here may support early detection of glaucoma and other eye disease.
Sight-threatening diabetic retinopathy at presentation to screening services in Fiji.
Damato, Erika M; Murray, Neil; Szetu, John; Sikivou, Biu Telaite; Emma, Stephanie; McGhee, Charles N J
2014-10-01
To report the spectrum of retinopathy at first presentation to photoscreening services, to determine the proportion of patients that present with sight-threatening diabetic retinopathy (STDR), and to raise awareness of the burden of diabetic eye disease in Fiji. This retrospective observational cohort study used data from the initial visit of all new patients presenting to the diabetes retinal screening service at the Pacific Eye Institute in Fiji over the 3-month period between July and September 2012. Patients were assessed using a detailed questionnaire regarding diabetes type, duration of disease, medications, complications and co-morbidities, and blood sugar control. Patients subsequently underwent non-mydriatic fundus photography according to Pacific diabetes retinal screening guidelines. Images were graded at the time of acquisition, and data were entered onto a computerized database. For the purposes of this study, information regarding retinopathy grading, visual acuity and patient demographics was used. A total of 522 new patients were screened over the 3-month period. STDR was observed in 27% of patients, with 15% observed to have bilateral STDR. Diabetes control was generally poor. Blindness and visual impairment were observed in 2.7% and 6.7% of the cohort, respectively. Severe and advanced diabetic retinopathy was present in this population presenting to screening. This was observed 4 years after the formal expansion of the screening services and reflects the high prevalence of diabetes in the population. The need for increased public awareness and greater resource allocation into diabetes and its complications is emphasized.
Mash, Bob; Powell, Di; du Plessis, Felicity; van Vuuren, Unita; Michalowska, Margaret; Levitt, Naomi
2007-12-01
In South Africa diabetes makes a significant contribution to the burden of disease. Diabetic retinopathy is a leading cause of adult blindness, and screening can reduce the incidence. This project aimed to implement and evaluate a new service for retinal screening that uses a non-mydriatic mobile fundal camera in primary care. This is the first time such a service has been evaluated in an African primary care context. The service was implemented as an operational research study at three community health centres and data were collected to evaluate the operational issues, screening, reporting and referral of patients. Out of 400 patients screened 84% had a significantly reduced visual acuity, 63% had retinopathy (22% severe nonproliferative, 6% proliferative and 15% maculopathy), 2% of eyes could not be screened and 14% of patients required dilatation. Referral was necessary in 27% of cases for cataracts, in 7% for laser treatment and in 4% for other specialist services. Repeat photography was needed in 8% and urgent follow-up in 12%. A SWOT analysis of the pilot project was completed and recommendations were made on how to integrate it into the district health system. Screening with a fundal camera improved the quality of care for diabetic patients and is feasible in the South African public sector, primary care setting. A single technician should be able to photograph almost 10,000 patients a year.
The use of retinal photography in non-ophthalmic settings and its potential for neurology
Pérez, Mario A.; Bruce, Beau B.; Newman, Nancy J.; Biousse, Valérie
2012-01-01
Background Ocular fundus examination is an important element of the neurological examination. However, direct ophthalmoscopy is difficult to perform without pupillary dilation and requires extensive practice to accurately recognize optic nerve and retinal abnormalities. Recent studies have suggested that digital retinal photography can replace direct ophthalmoscopy in many settings. Review Summary Ocular fundus imaging is routinely used to document and monitor disease progression in ophthalmology. Advances in optical technology have made it easier to obtain high-quality retinal imaging, even without pupillary dilation. Retinal photography has a high sensitivity, specificity, and inter-/intra-examination agreement compared to in-person ophthalmologist examination, suggesting that photographs can be used in lieu of ophthalmoscopy in many clinical situations. Non-mydriatic retinal photography has recently gained relevance as a helpful tool for diagnosing neuro-ophthalmologic disorders in the emergency department. Additionally, several population-based studies have used retinal imaging to relate ophthalmic abnormalities to the risk of hypertension, renal dysfunction, cardiovascular mortality, subclinical and clinical stroke, and cognitive impairment. The possibility of telemedical consultation offered by digital retinal photography has already increased access to timely and accurate subspecialty care, particularly for underserved areas. Conclusion Retinal photography (even without pupillary dilation) has become increasingly available to medical fields outside of ophthalmology, allowing for faster and more accurate diagnosis of various ocular, neurologic and systemic disorders. The potential for telemedicine may provide the additional benefits of improving access to appropriate urgent consultation in both clinical and research settings. PMID:23114666
Functional and Structural Changes in a Canine Model of Hereditary Primary Angle-Closure Glaucoma
Kecova, Helga; Harper, Matthew M.; Nilaweera, Wijitha; Kuehn, Markus H.; Kardon, Randy H.
2010-01-01
Purpose. To characterize functional and structural changes in a canine model of hereditary primary angle-closure glaucoma. Methods. Intraocular pressure (IOP) was evaluated with tonometry in a colony of glaucomatous dogs at 8, 15, 18, 20, and 30 months of age. Retinal function was evaluated using electroretinography (scotopic, photopic, and pattern). Examination of anterior segment structures was performed using gonioscopy and high-frequency ultrasonography (HFU). Results. A gradual rise in IOP was observed with an increase in age: 8 months, 14 mm Hg (median value); 15 months, 15.5 mm Hg; 18 months, 17.5 mm Hg; 20 months, 24 mm Hg; 30 months, 36 mm Hg. Provocative testing with mydriatic agents (tropicamide and atropine 1%) caused significant increases in IOP (35% and 50%, respectively). HFU analysis showed complete collapse of iridocorneal angles by 20 months of age. Scotopic and photopic ERG analysis did not reveal significant deficits, but pattern ERG analysis showed significantly reduced amplitudes in glaucomatous dogs (glaucoma, 3.5 ± 0.4 μV; control, 6.2 ± 0.3 μV; P = 0.004; Student's t-test). Histologic analysis revealed collapse of the iridocorneal angle, posterior bowing of the lamina cribrosa, swelling and loss of large retinal ganglion cells, increased glial reactivity, and increased thickening of the lamina cribrosa. Conclusions. Canine hereditary angle-closure glaucoma is characterized by a progressive increase in intraocular pressure, loss of optic nerve function, and retinal ganglion cell loss. PMID:19661222
Dhir, L; Habib, N E; Monro, D M; Rakshit, S
2010-06-01
The purpose of this study was to investigate the effect of cataract surgery and pupil dilation on iris pattern recognition for personal authentication. Prospective non-comparative cohort study. Images of 15 subjects were captured before (enrolment), and 5, 10, and 15 min after instillation of mydriatics before routine cataract surgery. After cataract surgery, images were captured 2 weeks thereafter. Enrolled and test images (after pupillary dilation and after cataract surgery) were segmented to extract the iris. This was then unwrapped onto a rectangular format for normalization and a novel method using the Discrete Cosine Transform was applied to encode the image into binary bits. The numerical difference between two iris codes (Hamming distance, HD) was calculated. The HD between identification and enrolment codes was used as a score and was compared with a confidence threshold for specific equipment, giving a match or non-match result. The Correct Recognition Rate (CRR) and Equal Error Rates (EERs) were calculated to analyse overall system performance. After cataract surgery, perfect identification and verification was achieved, with zero false acceptance rate, zero false rejection rate, and zero EER. After pupillary dilation, non-elastic deformation occurs and a CRR of 86.67% and EER of 9.33% were obtained. Conventional circle-based localization methods are inadequate. Matching reliability decreases considerably with increase in pupillary dilation. Cataract surgery has no effect on iris pattern recognition, whereas pupil dilation may be used to defeat an iris-based authentication system.
Høeg, Tracy B; Moldow, Birgitte; Klein, Ronald; La Cour, Morten; Klemp, Kristian; Erngaard, Ditte; Ellervik, Christina; Buch, Helena
2016-03-01
To examine non-mydriatic fundus photography (FP) and fundus autofluorescence (FAF) as alternative non-invasive imaging modalities to fluorescein angiography (FA) in the detection of cuticular drusen (CD). Among 2953 adults from the Danish Rural Eye Study (DRES) with gradable FP, three study groups were selected: (1) All those with suspected CD without age-related macular degeneration (AMD) on FP, (2) all those with suspected CD with AMD on FP and (3) a randomly selected group with early AMD. Groups 1, 2 and 3 underwent FA and FAF and group 4 underwent FAF only as part of DRES CD substudy. Main outcome measures included percentage of correct positive and correct negative diagnoses, Cohen's κ and prevalence-adjusted and bias-adjusted κ (PABAK) coefficients of test and grader reliability. CD was correctly identified on FP 88.9% of the time and correctly identified as not being present 83.3% of the time. CD was correctly identified on FAF 62.0% of the time and correctly identified as not being present 100.0% of the time. Compared with FA, FP has a PABAK of 0.75 (0.60 to 1.5) and FAF a PABAK of 0.44 (0.23 to 0.95). FP is a promising, non-invasive substitute for FA in the diagnosis of CD. FAF was less reliable than FP to detect CD. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Hysek, Cédric M; Liechti, Matthias E
2012-12-01
Pupillometry can be used to characterize autonomic drug effects. This study was conducted to determine the autonomic effects of 3,4-methylenedioxymethamphetamine (MDMA, ecstasy), administered alone and after pretreatment with reboxetine, duloxetine, clonidine, carvedilol, and doxazosin, on pupillary function. Infrared pupillometry was performed in five placebo-controlled randomized studies. Each study included 16 healthy subjects (eight men, eight women) who received placebo-MDMA (125 mg), placebo-placebo, pretreatment-placebo, or pretreatment-MDMA using a crossover design. MDMA produced mydriasis, prolonged the latency, reduced the response to light, and shortened the recovery time. The impaired reflex response was associated with subjective, cardiostimulant, and hyperthermic drug effects and returned to normal within 6 h after MDMA administration when plasma MDMA levels were still high. Mydriasis was associated with changes in plasma MDMA concentration over time and longer-lasting. Both reboxetine and duloxetine interacted with the effects of MDMA on pupillary function. Clonidine did not significantly reduce the mydriatic effects of MDMA, although it produced miosis when administered alone. Carvedilol and doxazosin did not alter the effects of MDMA on pupillary function. The MDMA-induced prolongation of the latency to and reduction of light-induced miosis indicate indirect central parasympathetic inhibition, and the faster recovery time reflects an increased sympathomimetic action. Both norepinephrine and serotonin mediate the effects of MDMA on pupillary function. Although mydriasis is lasting and mirrors the plasma concentration-time curve of MDMA, the impairment in the reaction to light is associated with the subjective and other autonomic effects of MDMA and exhibits acute tolerance.
NASA Astrophysics Data System (ADS)
Motta, Danilo A.; Serillo, André; de Matos, Luciana; Yasuoka, Fatima M. M.; Bagnato, Vanderlei S.; Carvalho, Luis A. V.
2014-03-01
Glaucoma is the second main cause of the blindness in the world and there is a tendency to increase this number due to the lifetime expectation raise of the population. Glaucoma is related to the eye conditions, which leads the damage to the optic nerve. This nerve carries visual information from eye to brain, then, if it has damage, it compromises the visual quality of the patient. In the majority cases the damage of the optic nerve is irreversible and it happens due to increase of intraocular pressure. One of main challenge for the diagnosis is to find out this disease, because any symptoms are not present in the initial stage. When is detected, it is already in the advanced stage. Currently the evaluation of the optic disc is made by sophisticated fundus camera, which is inaccessible for the majority of Brazilian population. The purpose of this project is to develop a specific fundus camera without fluorescein angiography and red-free system to accomplish 3D image of optic disc region. The innovation is the new simplified design of a stereo-optical system, in order to make capable the 3D image capture and in the same time quantitative measurements of excavation and topography of optic nerve; something the traditional fundus cameras do not do. The dedicated hardware and software is developed for this ophthalmic instrument, in order to permit quick capture and print of high resolution 3D image and videos of optic disc region (20° field-of-view) in the mydriatic and nonmydriatic mode.
Rodríguez Villa, Susana; Suárez Muñiz, María Teresa; De Dios Del Valle, Ricardo; Alonso Álvarez, Crisanto
To compare the evaluation of retinographies by a teleophthalmology nurse and primary care physicians (PCP) with an ophthalmologist referral hospital (gold standard). Cross-sectional study on a random sample of 337 patients on the teleophthalmology programme from January 2010 to January 2015. We analyzed the diagnostic evaluation (whether or not it presented findings of RD) and the therapeutic assessment (whether or not referral to the opthalmology department was needed) which were conducted independently on the sample retinographies by the PCP, a nurse and an ophthalmologist (gold standard). Reliability and concordance between the gold standard and the PCP and the nurse were checked and the statistical analyses were supported using SPSSv.23.00 software and diagnostic test reliability calculators (EPIDAT 4.1). In the diagnosis of RD, the nurse presented: sensitivity (S): 0.96; specificity (Sp): 0.89; PPV: 0.58; NPV: 0.99; Kappa index: 0.67 and PCP: S: 0.98; Sp: 0.99; PPV: 0.96; NPV: 0.99; Kappa index: 0.96. In the referral to ophthalmology assessed by the nurse: S: 0.83; Sp: 0.83; PPV: 0.51; NPV: 0.96; Kappa Index: 0.53 and PCP: S: 0.62; Sp: 0.76; PPV: 0.36; NPV: 0.90; Kappa index: 0.29. A nursing teleophthalmology programme could perform population screening for RD with the same quality as PCP. This would increase coverage, in addition to providing better use of resources by avoiding intermediate patient appointments through PCP and increased health savings. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.
Consensual pupillary light response in the red-eared slider turtle (Trachemys scripta elegans).
Dearworth, James R; Sipe, Grayson O; Cooper, Lori J; Brune, Erin E; Boyd, Angela L; Riegel, Rhae A L
2010-03-17
Purpose of this study was to determine if the turtle has a consensual pupillary light response (cPLR), and if so, to compare it to its direct pupillary light response (dPLR). One eye was illuminated with different intensities of light over a four log range while keeping the other eye in darkness. In the eye directly illuminated, pupil diameter was reduced by as much as approximately 31%. In the eye not stimulated by light, pupil diameter was also reduced but less to approximately 11%. When compared to the directly illuminated eye, this generated a ratio, cPLR-dPLR, equal to 0.35. Ratio of slopes for log/linear fits to plots of pupil changes versus retinal irradiance for non-illuminated (-1.27) to illuminated (-3.94) eyes closely matched at 0.32. cPLR had time constants ranging from 0.60 to 1.20min; however, they were comparable and not statistically different from those of the dPLR, which ranged from 1.41 to 2.00min. Application of mydriatic drugs to the directly illuminated eye also supported presence of a cPLR. Drugs reduced pupil constriction by approximately 9% for the dPLR and slowed its time constant to 9.58min while simultaneous enhancing constriction by approximately 6% for the cPLR. Time constant for the cPLR at 1.75min, however, was not changed. Results support that turtle possesses a cPLR although less strong than its dPLR. Copyright 2010 Elsevier Ltd. All rights reserved.
Savige, Judy; Wang, Yanyan; Crawford, Andrew; Smith, James; Symons, Andrew; Mack, Heather; Nicholls, Kathy; Wilson, Diane; Colville, Deb
2017-01-01
The retinal features of Alport syndrome include a central and peripheral fleck retinopathy, temporal retinal thinning, and a macular hole. Here we describe further retinal abnormalities. We identified a case of bull's eye maculopathy 20 years previously in a 68-year-old female, and reviewed archived retinal images from our cohort of X-linked (28 males, 28 females) or autosomal recessive (n = 13) Alport syndrome. All individuals had Alport syndrome confirmed on genetic testing or renal biopsy, were examined by an ophthalmologist, and underwent retinal imaging (KOWA non-mydriatic camera, Japan). The index case had the p.Q379X variant in COL4A5 and currently had renal impairment, (eGFR = 45 ml/min/1.73 m 2 ), bilateral hearing loss, and central and peripheral retinopathies. Her maculopathy had deteriorated, and she had a bilateral central visual field loss. Optical coherence tomography (Heidelberg Spectralis) demonstrated a disrupted retinal pigment epithelium and retinal atrophy. We identified a further early bull's eye maculopathy (1/69, 1.4%) from a female with autosomal recessive disease and normal renal function. We also noted a subtle pigment maculopathy associated with an abnormal retinal pigment epithelium in 27 (27/69, 39%) subjects with Alport syndrome, in both males (8/28, 29%) and females (13/28, 46%) with X-linked disease, and in autosomal recessive disease (6/13, 38%). The bull's eye and pigment maculopathies in Alport syndrome result mainly from the damaged Bruch's membrane and overlying retinal pigment epithelium. Bull's eye maculopathy affects vision and patients should undergo regular monitoring for retinal complications.
The change points of HbA(1C) for detection of retinopathy in Chinese type 2 diabetic patients.
Hou, Jia-Ning; Bi, Yu-Fang; Xu, Min; Huang, Yun; Li, Xiao-Ying; Wang, Wei-Qing; Chen, Yu-Hong; Ning, Guang
2011-03-01
To investigate the change points of HbA(1C) for detection of retinopathy in Chinese type 2 diabetic patients. This cross-sectional investigation included 992 diagnosed type 2 diabetic patients, who received non-mydriatic digital fundus photography examination. Joinpoint regression software was adopted to identify the change points of HbA(1C) in association with retinopathy prevalence. The mean age of all patients was 59.1 ± 8.4 years and the duration of diabetes was 5.5 (95% CI: 5.2-5.9) years. The prevalence of retinopathy was 10.3% in total, and 4.1%, 7.4% and 19.6% in patients with different diabetes duration of ≤ 5 years, 5-10 years and >10 years, respectively. The change point of HbA(1C) was 6.5% (95%CI 5.8-7.5%), at which retinopathy prevalence began to rise sharply. Furthermore, in subjects with diabetes duration ≤ 5 years, 5-10 years and >10 years, the change points of HbA(1C) were 8.1% (95%CI 7.9-8.3%), 6.1% (95%CI 5.7-6.8%), 5.6% (95%CI 5.1-8.1%) for detection of retinopathy, respectively. The steepest increase in retinopathy prevalence occurred when HbA(1C) reached 6.5%. However, the duration of diabetes should be taken into concern, when using the change points of HbA(1C) for detection of retinopathy in diabetic patients. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Wu, Ying; He, Ji C.; Zhou, Xing T.; Chu, Ren Y.
2015-01-01
Purpose To explore the relationship between ablation parameters of myopic laser surgery and measurement area of wavefront aberration (WA) with Hartmann-Shack wavefront sensor. Methods 58 subjects undergone myopic laser surgeries and 74 uncorrected myopic subjects were enrolled in this experiment. The laser ablation parameters were obtained from surgical records, which included spherical error (Rx), depth, and optical zone (OZ) of ablation. The measured area of WA was tested by the WASCA, and the real pupil size was tested by Pentacam. The corneal eccentricity (E value) and curvature was also measured with the Pentacam. All the measurements were performed under mydriatic condition. Results For uncorrected myopic eyes, the measured area of WA was similar with the real pupil size. But for the corrected eyes, the measured area of WA was smaller than the real pupil size with a mean difference of 0.66 ± 0.54 mm for moderate myopia (t = 6.45, p < 0.0001) and 1.76 ± 0.55 mm for high myopia (t = 18.92, p < 0.0001), but not for mild myopia. The Rx (t = -3.20, p = 0.0017), OZ (t = 64.4, p < 0.0001) and postoperative corneal E value (t = 2.52, p = 0.017) were the independent factors of measured area of WA. Measured area of WA = -0.81*Rx + 1.13*OZ + 0.49*postoperative corneal E value (r2 = 0.997). Conclusions The WASCA has a limitation in measuring wavefront aberration over the whole pupil area when it’s used for patients received myopic laser surgery. The measured area is smaller than the real pupil size and depends linearly on ablation depth, optical zone and corneal eccentricity. PMID:25692489
2013-01-01
Background Diabetes mellitus type 2 (DM2) is highly associated with increased risk for chronic kidney disease (CKD), end stage renal disease (ESRD) and cardiovascular morbidity. Epidemiological and genetic studies generate hypotheses for innovative strategies in DM2 management by unravelling novel mechanisms of diabetes complications, which is essential for future intervention trials. We have thus initiated the DIAbetes COhoRtE study (DIACORE). Methods DIACORE is a prospective cohort study aiming to recruit 6000 patients of self-reported Caucasian ethnicity with prevalent DM2 for at least 10 years of follow-up. Study visits are performed in University-based recruiting clinics in Germany using standard operating procedures. All prevalent DM2 patients in outpatient clinics surrounding the recruiting centers are invited to participate. At baseline and at each 2-year follow-up examination, patients are subjected to a core phenotyping protocol. This includes a standardized online questionnaire and physical examination to determine incident micro- and macrovascular DM2 complications, malignancy and hospitalization, with a primary focus on renal events. Confirmatory outcome information is requested from patient records. Blood samples are obtained for a centrally analyzed standard laboratory panel and for biobanking of aliquots of serum, plasma, urine, mRNA and DNA for future scientific use. A subset of the cohort is subjected to extended phenotyping, e.g. sleep apnea screening, skin autofluorescence measurement, non-mydriatic retinal photography and non-invasive determination of arterial stiffness. Discussion DIACORE will enable the prospective evaluation of factors involved in DM2 complication pathogenesis using high-throughput technologies in biosamples and genetic epidemiological studies. PMID:23409726
Sahli, Michelle W; Mares, Julie A; Meyers, Kristin J; Klein, Ronald; Brady, William E; Klein, Barbara E K; Ochs-Balcom, Heather M; Donahue, Richard P; Millen, Amy E
2016-01-01
We tested the hypothesis that dietary intake of lutein is inversely associated with prevalence of diabetic retinopathy (DR) due to its antioxidant and anti-inflammatory properties and location within the retina. We used logistic regression to examine the association between prevalent DR and energy-adjusted lutein intake by quartile (Q) using data collected from 1430 Atherosclerosis Risk in Communities Study (ARIC) participants with diabetes (n = 994 white, n = 508 black). DR was assessed from 45° non-mydriatic retinal photographs of one randomly chosen eye taken at visit 3 (1993-1995). Dietary lutein intake was estimated using a 66-item food frequency questionnaire at visit 1 (1987-1989). Median estimated daily lutein intake was 1370 µg/1000 kcals and prevalence of DR was ~21%. We found a crude association between lutein and DR (odds ratio, OR, 2.11, 95% confidence interval, CI, 1.45-3.09 for Q4, high intake, vs. Q1, low intake; p for trend <0.0001), which was attenuated after adjustment for ethnicity, duration of diabetes, glycosylated hemoglobin levels, field center and energy intake (OR 1.41, 95% CI 0.87-2.28; p for trend = 0.01). In analyses limited to persons with short diabetes duration (<6 years), the association no longer persisted (OR 0.94, 95% CI 0.31-2.16; p for trend =0.72) compared to the association in those with longer diabetes duration (≥6 years; OR 1.58, 95% CI 0.91-2.75; p for trend = 0.01). Contrary to our hypothesis, we found that the odds of higher lutein intake were greater among those with DR than those without DR. However, after adjusting for confounders, intake of lutein was not associated with DR.
Registration of retinal sequences from new video-ophthalmoscopic camera.
Kolar, Radim; Tornow, Ralf P; Odstrcilik, Jan; Liberdova, Ivana
2016-05-20
Analysis of fast temporal changes on retinas has become an important part of diagnostic video-ophthalmology. It enables investigation of the hemodynamic processes in retinal tissue, e.g. blood-vessel diameter changes as a result of blood-pressure variation, spontaneous venous pulsation influenced by intracranial-intraocular pressure difference, blood-volume changes as a result of changes in light reflection from retinal tissue, and blood flow using laser speckle contrast imaging. For such applications, image registration of the recorded sequence must be performed. Here we use a new non-mydriatic video-ophthalmoscope for simple and fast acquisition of low SNR retinal sequences. We introduce a novel, two-step approach for fast image registration. The phase correlation in the first stage removes large eye movements. Lucas-Kanade tracking in the second stage removes small eye movements. We propose robust adaptive selection of the tracking points, which is the most important part of tracking-based approaches. We also describe a method for quantitative evaluation of the registration results, based on vascular tree intensity profiles. The achieved registration error evaluated on 23 sequences (5840 frames) is 0.78 ± 0.67 pixels inside the optic disc and 1.39 ± 0.63 pixels outside the optic disc. We compared the results with the commonly used approaches based on Lucas-Kanade tracking and scale-invariant feature transform, which achieved worse results. The proposed method can efficiently correct particular frames of retinal sequences for shift and rotation. The registration results for each frame (shift in X and Y direction and eye rotation) can also be used for eye-movement evaluation during single-spot fixation tasks.
NASA Astrophysics Data System (ADS)
Joshi, V.; Wigdahl, J.; Nemeth, S.; Zamora, G.; Ebrahim, E.; Soliz, P.
2018-02-01
Retinal abnormalities associated with hypertensive retinopathy are useful in assessing the risk of cardiovascular disease, heart failure, and stroke. Assessing these risks as part of primary care can lead to a decrease in the incidence of cardiovascular disease-related deaths. Primary care is a resource limited setting where low cost retinal cameras may bring needed help without compromising care. We compared a low-cost handheld retinal camera to a traditional table top retinal camera on their optical characteristics and performance to detect hypertensive retinopathy. A retrospective dataset of N=40 subjects (28 with hypertensive retinopathy, 12 controls) was used from a clinical study conducted at a primary care clinic in Texas. Non-mydriatic retinal fundus images were acquired using a Pictor Plus hand held camera (Volk Optical Inc.) and a Canon CR1-Mark II tabletop camera (Canon USA) during the same encounter. The images from each camera were graded by a licensed optometrist according to the universally accepted Keith-Wagener-Barker Hypertensive Retinopathy Classification System, three weeks apart to minimize memory bias. The sensitivity of the hand-held camera to detect any level of hypertensive retinopathy was 86% compared to the Canon. Insufficient photographer's skills produced 70% of the false negative cases. The other 30% were due to the handheld camera's insufficient spatial resolution to resolve the vascular changes such as minor A/V nicking and copper wiring, but these were associated with non-referable disease. Physician evaluation of the performance of the handheld camera indicates it is sufficient to provide high risk patients with adequate follow up and management.
Vofo, Brice N; Ngankam, Gaelle V F; Ngwasiri, Calypse A; Atem, Jeannine A; Aminde, Leopold N
2018-05-16
Endemic Burkitt's lymphoma is found predominantly in malaria holoendemic zones, typically in the tropical rain forest of Africa. It usually presents as an extra-nodal tumour in children and young adults with predilection for jaws and soft tissues of the abdomen. Clinical features depend on the primary tumour site, extent of the disease and histologic subtype. Acute blindness as a presentation sign is rare. A 13 year old African female presented to our facility with a 3 week history of painful abdominal distention, and loss of vision of the left eye. On examination, there was a huge abdominopelvic mass, left breast mass and complete blindness of the left eye associated with mydriatic pupils non-responsive to light. An abdominal ultrasound showed a huge hypoechoic mass arising from the pelvis and protruding into the abdomen. The jaws, teeth and maxilla were all normal. A fine needle aspiration done was negative for malignant cells. A presumptive diagnosis of Burkitt's lymphoma was made on clinical grounds and abdominal ultrasound findings. The patient was immediately placed on chemotherapy and responded well to treatment with remission of the tumour but persistence of left eye blindness. Acute blindness can be the presenting sign of Burkitt's lymphoma in a patient with neither jaw nor maxillary swelling. Primary healthcare providers in low income settings require a high index of suspicion when faced with such atypical presentations. This emphasizes the need for thorough physical examination, and when possible, the clinical utility of ultrasonography for suspicious abdominal masses in the absence of state-of the art diagnostic tools for early diagnosis and treatment, which is critical for survival and to improve quality of life.
Healy, Rachel; Sallam, Ahmed; Jones, Vanessa; Donachie, Paul H J; Scanlon, Peter H; Stratton, Irene M; Johnston, Robert L
2014-01-01
To examine the level of agreement and reasons for disagreement between grading of diabetic retinopathy and maculopathy using mydriatic digital photographs in a diabetic retinopathy screening service (DRSS) and hospital eye service (HES). English NHS Diabetic Eye Screening Programme grades for diabetic retinopathy prospectively recorded on a hospital electronic medical record were compared to the grades from the DRSS event that prompted referral. In cases of disagreement, images were reviewed. Data for 1,501 patients (3,002 eyes) referred between 2008 and 2011 were analyzed. The HES retinopathy grades were R0 (no retinopathy) in 341 eyes, R1 (background retinopathy) in 1,712 eyes, R2 (pre-proliferative retinopathy) in 821 eyes, and R3 (proliferative retinopathy) in 128 eyes. The DRSS grades were in agreement in 2,309 eyes (76.9%), recorded a lower grade in 227 eyes, and recorded a higher grade in 466 eyes. Agreement was substantial (κ = 0.65). The commonest cause for disagreement was overgrading of R1 as R2 by hospital clinicians. The HES maculopathy grades were M0 (no maculopathy) in 2,267 eyes and M1 (maculopathy) in 735 eyes. The DRSS were in agreement in 2,111 eyes (70.2%), recorded a lower grade in 106 eyes, and recorded a higher grade in 785 eyes. Agreement was fair (κ = 0.39). The commonest cause for disagreement was hospital clinicians missing fine exudates. This study establishes a benchmark standard for agreement between HES and DRSS grading. Review of DRSS and grading reports images for newly referred patients is likely to improve levels of agreement, particularly for diabetic retinopathy, and should be strongly encouraged.
Scanlon, Peter H; Stratton, Irene M; Histed, Mark; Chave, Steve J; Aldington, Stephen J
2013-08-01
The Gloucestershire Diabetic Eye Screening Programme offers annual digital photographic screening for diabetic retinopathy to a countywide population of people with diabetes. This study was designed to investigate progression of diabetic retinopathy in this programme of the English NHS Diabetic Eye Screening Programme. Mydriatic digital retinal photographs of people with diabetes screened on at least 2 occasions between 2005 and 2010 were graded and included in this study if the classification at first screening was no DR (R0), background DR in one (R1a) or both eyes (R1b). Times to detection of referable diabetic retinopathy (RDR) comprising maculopathy (M1), preproliferative (R2) or proliferative retinopathy (R3) were analysed using survival models. Data were available on 19 044 patients, 56% men, age at screening 66 (57-74) years (median, 25th, 75th centile). A total of 8.3% of those with R1a and 28.2% of those with R1b progressed to any RDR, hazard ratios 2.9 [2.5-3.3] and 11.3 [10.0-12.8]. Similarly 7.1% and 0.11% of those with R1a progressed to M1 and R3, hazard ratios 2.7 [2.3-3.2] and 1.6 [0.5-5.0], compared to 21.8% and 1.07% of those with R1b, hazard ratio 9.1 [7.8-10.4] and 15.0 [7.1-31.5]. The risk of progression is significantly higher for those with background DR in both eyes than those with background retinopathy in only one or in neither eye. © 2013 The Authors Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by Blackwell Publishing Ltd.
Scanlon, P H; Aldington, S J; Stratton, I M
2014-04-01
To assess whether there is a relationship between delay in retinopathy screening after diagnosis of type 2 diabetes and level of retinopathy detected. Patients were referred from 88 primary care practices to an English National Health Service diabetic eye screening programme. Data for screened patients were extracted from the primary care databases using semi-automated data collection algorithms supplemented by validation processes. The programme uses two-field mydriatic digital photographs graded by a quality assured team. Data were available for 8183 screened patients with diabetes newly diagnosed in 2005, 2006 or 2007. Only 163 with type 1 diabetes were identified and were insufficient for analysis. Data were available for 8020 with newly diagnosed type 2 diabetes. Of these, 3569 were screened within 6 months, 2361 between 6 and 11 months, 1058 between 12 and 17 months, 366 between 18 and 23 months, 428 between 24 and 35 months, and 238 at 3 years or more after diagnosis. There were 5416 (67.5%) graded with no retinopathy, 1629 (20.3%) with background retinopathy in one eye, 753 (9.4%) with background retinopathy in both eyes and 222 (2.8%) had referable diabetic retinopathy. There was a significant trend (P = 0.0004) relating time from diagnosis to screening detecting worsening retinopathy. Of those screened within 6 months of diagnosis, 2.3% had referable retinopathy and, 3 years or more after diagnosis, 4.2% had referable retinopathy. The rate of detection of referable diabetic retinopathy is elevated in those who were not screened promptly after diagnosis of type 2 diabetes. © 2013 The Authors. Diabetic Medicine published by John Wiley & Sons Ltd on behalf of Diabetes UK.
Light and portable novel device for diabetic retinopathy screening.
Ting, Daniel S W; Tay-Kearney, Mei Ling; Kanagasingam, Yogesan
2012-01-01
To validate the use of an economical portable multipurpose ophthalmic imaging device, EyeScan (Ophthalmic Imaging System, Sacramento, CA, USA), for diabetic retinopathy screening. Evaluation of a diagnostic device. One hundred thirty-six (272 eyes) were recruited from diabetic retinopathy screening clinic of Royal Perth Hospital, Western Australia, Australia. All patients underwent three-field (optic disc, macular and temporal view) mydriatic retinal digital still photography captured by EyeScan and FF450 plus (Carl Zeiss Meditec, North America) and were subsequently examined by a senior consultant ophthalmologist using the slit-lamp biomicroscopy (reference standard). All retinal images were interpreted by a consultant ophthalmologist and a medical officer. The sensitivity, specificity and kappa statistics of EyeScan and FF450 plus with reference to the slit-lamp examination findings by a senior consultant ophthalmologist. For detection of any grade of diabetic retinopathy, EyeScan had a sensitivity and specificity of 93 and 98%, respectively (ophthalmologist), and 92 and 95%, respectively (medical officer). In contrast, FF450 plus images had a sensitivity and specificity of 95 and 99%, respectively (ophthalmologist), and 92 and 96%, respectively (medical officer). The overall kappa statistics for diabetic retinopathy grading for EyeScan and FF450 plus were 0.93 and 0.95 for ophthalmologist and 0.88 and 0.90 for medical officer, respectively. Given that the EyeScan requires minimal training to use and has excellent diagnostic accuracy in screening for diabetic retinopathy, it could be potentially utilized by the primary eye care providers to widely screen for diabetic retinopathy in the community. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.
Gräsbeck, Thomas C; Gräsbeck, Sophia V; Miettinen, Päivi J; Summanen, Paula A
2016-09-01
To determine the success rate of the initial fundus photography session in producing gradable images for screening diabetic retinopathy in children <18 years of age with type 1 diabetes (T1D), and to analyze outcome-associated factors. Retrospective observational cohort study. Mydriatic red-free monochromatic 60-degree digital fundus images centered on the macula and optic disc of 213 patients were graded. Photography success was classified as "complete" if both images of both eyes were gradable, "partial" if both images of 1 eye were gradable, "macula-centered image(s) only" if only the macula-centered image of one or both eyes was gradable, and "unsuccessful" if neither macula-centered image was gradable. Complete success was reached in 97 (46%; 95% confidence interval [CI], 39-52) patients, at least partial success in 153 (72%; 95% CI, 65-78) patients, success of macula-centered image(s) only in 47 (22%; 95% CI, 17-28) patients, and in 13 (6%; 95%CI, 3-10) patients fundus photography was unsuccessful. Macula-centered images were more often gradable in both eyes than optic disc-centered images (P < .001). Success of photography did not differ between right and left eye. Sex, age at diagnosis of T1D, and the duration of diabetes, age, and glycemic control at the time of initial photography were unassociated with complete success. Partial success tended to decrease with increasing age category (P = .093), and the frequency of gradable macula-centered image(s) only increased with increasing age (P = .043). Less than half of the children achieved complete success, but in only 6% initial fundus photography was unsuccessful, indicating its value in assessing retinopathy in the pediatric setting. Copyright © 2016 Elsevier Inc. All rights reserved.
Rush, Ryan; Rush, Sloan; Nicolau, John; Chapman, Karen; Naqvi, Mubariz
2004-04-01
To determine whether adverse effects manifested via vital sign changes during the screening examination for retinopathy of prematurity (ROP) are due to the pharmacologic properties of the eye drops or to physical manipulation of the eyes. The authors also investigated the relationship between distress during the screening process and the severity of prematurity of the infant. A prospective observational study was designed that enrolled all infants either weighing < or =1500 g or who were < or =32 weeks gestational age at birth who were admitted to the neonatal intensive care unit (NICU) at Northwest Texas Hospital or Baptist St. Anthony's Hospital from June 2002 to February 2003. Thirty participants were enrolled in this study. Blood pressure, pulse, temperature, respiratory rate, and O2 saturation were recorded at different time intervals during the examination. Infants were excluded from the study if they were on the ventilator, considered acutely ill, born with significant birth defects, or currently taking inotropic drugs, or had received albuterol 2 hours before the examination. Oxygen saturation and pulse rate following physical manipulation of the eyes significantly varied from baseline values and the values obtained during the three instillations of topical mydriatics. No significant changes in blood pressure, temperature, or respiratory rate from their respective baseline values were observed throughout the ROP screening examination. Gestational age of the infant did not correlate with level of distress during the examination. Regardless of the severity of prematurity, infants seem to undergo significant distress during the eyelid speculum examination. Thus ophthalmologists should take into consideration the infant's discomfort caused by physical manipulation of the eyes and attempt to perform the examination as swiftly, yet safely, as possible using topical anesthetic.
[Static Retinal Vessel Analysis in Population-based Study SHIP-Trend].
Theophil, Constanze; Jürgens, Clemens; Großjohann, Rico; Kempin, Robert; Ittermann, Till; Nauck, Matthias; Völzke, Henry; Tost, Frank H W
2017-08-24
Background Interdisciplinary investigations of possible connections between general diseases and ophthalmological changes are difficult to perform in the clinical environment. But they are gaining in importance as a result of the age-related increase in chronic diseases. The collection of health-related parameters in the Study of Health in Pomerania (SHIP) project allows to derive conclusions for the general population. Methods The population-based SHIP trend study was conducted between 2008 and 2012 in Greifswald. The baseline cohort included 4420 subjects (response 50.1%) at the age of 20 to 84 years. The pre-existence of arterial hypertension, diabetes mellitus and smoking status were questioned in a standardized questionnaire, the blood pressure and the HbA 1c were determined by the laboratory. The vascular diameter of retinal arterioles and venules were determined by means of non-mydriatic fundus images and the retinal arterial (CRAE) and venous equivalent (CRVE) were calculated therefrom. The association of diabetes mellitus, HbA 1c , smoking status and blood pressure with the retinal vascular parameters was tested for age and sex with linear regression models. Results In 3218 subjects with evaluable standardized fundus photographs, significant associations of elevated HbA 1c (> 6.5%), smoking status and systolic and diastolic blood pressure were found with the retinal vessel widths CRAE and CRVE. Anamnestic diabetes mellitus, on the other hand, was not associated with any of the vascular parameters. Conclusion This research study reveals a relevant correlation between general diseases and the retinal blood flow in the eye. Therefore, general diseases can induce ophthalmological changes and eye examination can provide information for the assessment of general diseases. Georg Thieme Verlag KG Stuttgart · New York.
Systemic changes and adverse effects induced by retinopathy of prematurity screening.
Jiang, Jing-Bo; Zhang, Zhi-Wei; Zhang, Jia-Wen; Wang, Yan-Li; Nie, Chuan; Luo, Xian-Qiong
2016-01-01
To estimate the potential systemic events during and after retinopathy of prematurity (ROP) screening. A prospective and descriptive designed study was conducted to detect the physiologic and pathological changes 24h before, during, and 72h after ROP screening. Control blood pressure (BP), saturation, pulse rate, and body temperature were routinely taken at various time internals before and after screening. Adverse effects pertain to cardiovascular system, respiratory system, gastric system, urinary system and nervous system were retrospect 0-72h after ROP screening at a 24-hour interval. Totally 1254 prematurity babies receiving ROP screening during Jan. 1(st) 2013 to Dec. 31(th) 2013 were enrolled in our survey. Compared to control vital sign data taken before the examination, there was a fluctuation in the diastolic BP with the increased 3.03 mm Hg (P=0.04) after 3 doses of mydriatic drops. Immediately after the examination, there was a further 12.64 mm Hg (P<0.01) increase in systolic BP and a 7.24 mm Hg (P<0.01) in diastolic BP. The mean pulse rate during examination was 22.4 bpm (P<0.01) higher than the 133.3±9.0 bpm control level. The oxygen saturation shared an average drop of 5% (P<0.01) during screening. In prematurity with postconceptional age less than 31wk, the incidence of apnea (23.5%), necrotizing enterocolitis (NEC) (8.7%), gastric residual (25.4%) and upper digestive tract hemorrhage (6.4%) also demonstrated a significant rise (P<0.01). In our study sample, ROP screening was associated with NEC, gastric residual and upper digestive tract hemorrhage. These gastrointestinal side effects, along with breath activity pattern change and vital signs indicators fluctuation, may be results of additional stress responses.
Early signal of diverted use of tropicamide eye drops in France.
Ponté, Camille; Pi, Christian; Palmaro, Aurore; Jouanjus, Emilie; Lapeyre-Mestre, Maryse
2017-08-01
Tropicamide is a mydriatic drug used as eye-drops for diagnostic or therapeutic purposes. From 2013, a diverted use by intravenous route has been suspected in Eastern Europe in opioids users. To date, no signal of misuse has been identified in France. The aims of this study were to investigate any early signals of a diverted use of tropicamide eye drops and to collect information regarding motives for the misuse and tropicamide-induced effects. Information was obtained at three levels: (1) at regional level (Midi-Pyrénées area), from reimbursement data and pharmacists' reports on suspicious requests; (2) at national level: from reimbursement data and prescriptions suggesting possible abuse from the OSIAP (Ordonnances Suspectes, Indicateur d'Abus Possible) survey; and (3) at international level: from VigiBase ® reports and Web sources. Beta-blocker eye-drops were used as comparators. In France, in 2014-2015, 17 (0.91%, 95% CI [0.53-1.46%]) falsified prescriptions involving tropicamide were identified in the OSIAP survey (compared with 0%, 95% CI [0-0.19%] for beta-blockers). Moreover, 37 other suspicious prescriptions were presented in 2015 (notified in 2016). In Midi-Pyrénées, seven patients aged 35-49 were reimbursed for 19-45 vials of 10 ml, in a year. Since September 2014, the regional Addictovigilance Centre has received 91 notifications of suspicious requests to obtain tropicamide. In VigiBase ® , two cases were identified but none in France. An increased interest in tropicamide-related Internet searches was observed from Russia and Ukraine. These results represent the first early warnings of a tropicamide diverted use in France. Tropicamide abusers would seek euphoria or hallucinations. The high doses involved in intravenous administration could lead to serious complications. © 2017 The British Pharmacological Society.
Whited, John D; Datta, Santanu K; Aiello, Lloyd M; Aiello, Lloyd P; Cavallerano, Jerry D; Conlin, Paul R; Horton, Mark B; Vigersky, Robert A; Poropatich, Ronald K; Challa, Pratap; Darkins, Adam W; Bursell, Sven-Erik
2005-12-01
The objective of this study was to compare, using a 12-month time frame, the cost-effectiveness of a non-mydriatic digital tele-ophthalmology system (Joslin Vision Network) versus traditional clinic-based ophthalmoscopy examinations with pupil dilation to detect proliferative diabetic retinopathy and its consequences. Decision analysis techniques, including Monte Carlo simulation, were used to model the use of the Joslin Vision Network versus conventional clinic-based ophthalmoscopy among the entire diabetic populations served by the Indian Health Service, the Department of Veterans Affairs, and the active duty Department of Defense. The economic perspective analyzed was that of each federal agency. Data sources for costs and outcomes included the published literature, epidemiologic data, administrative data, market prices, and expert opinion. Outcome measures included the number of true positive cases of proliferative diabetic retinopathy detected, the number of patients treated with panretinal laser photocoagulation, and the number of cases of severe vision loss averted. In the base-case analyses, the Joslin Vision Network was the dominant strategy in all but two of the nine modeled scenarios, meaning that it was both less costly and more effective. In the active duty Department of Defense population, the Joslin Vision Network would be more effective but cost an extra 1,618 dollars per additional patient treated with panretinal laser photo-coagulation and an additional 13,748 dollars per severe vision loss event averted. Based on our economic model, the Joslin Vision Network has the potential to be more effective than clinic-based ophthalmoscopy for detecting proliferative diabetic retinopathy and averting cases of severe vision loss, and may do so at lower cost.
Aydin, Nazan; Kotan, Dilcan; Keles, Sadullah; Ondas, Osman; Aydin, Mehmet Dumlu; Baykal, Orhan; Gundogdu, Betul
2016-09-06
Photophobia is defined as a painful psychosomatic discomfort triggered by intense light flow through the pupils to the brain, but the exact mechanism through which photophobia is induced by subarachnoid hemorrhage (SAH) is not well understood. In this study, we aimed to investigate whether there was any relationship between the mydriasis induced by the degeneration of the ciliary ganglion (CG) and photophobia in instances of SAH. Five of a total of 25 rabbits were used as the intact control group; five were used in the sham-operated control group; and the remaining 15 were used as the SAH group, which was created by injecting autologous blood into their cisterna magna. All animals were examined daily for 20days to evaluate their level of photophobia, after which their brains, CGs and superior cervical ganglia (SCGs) were extracted bilaterally. The densities of normal and degenerated neurons in these ganglia were examined by stereological methods. In SAH animals with a high photophobia score, the mean pupil diameter and density of degenerated neurons density in the CG were greater than in cases with a low photophobia score (p<0.05). Further analysis revealed that the increase in the density of degenerated neurons in the CG following SAH resulted in the paralysis of the parasympathetic pathway of the pupillary muscles and mydriasis, which facilitates the excessive transfer of light to the brain and photophobia. Our findings indicate that SAH results in a high density of degenerated neurons in the CG, which induces mydriasis and is an important factor in the onset of photophobia. This phenomenon is likely due to more light energy being transferred through mydriatic pupils to the brain, resulting in vasospasm of the supplying arteries. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Bhuachalla, Bláithín Ní; McGarrigle, Christine A; O'Leary, Neil; Akuffo, Kwadwo Owusu; Peto, Tunde; Beatty, Stephen; Kenny, Rose Anne
2018-06-01
Age related macular degeneration (AMD) is a leading cause of irreversible visual loss in developed countries. It is associated with vascular risk factors including hypertension. Dysregulated blood pressure (BP) behaviour including orthostatic hypertension (OHTN), hypotension (OH) and BP variability (BPV) are associated with end-organ damage, particularly in the brain. We investigated if abnormal orthostatic BP (OBP) was a risk factor for AMD, for which a vascular aetiology is implicated. A nationally representative, cross-sectional study was carried out 2009/2010 in The Irish Longitudinal Study on Ageing (TILDA). Beat-to-beat BP data, measured by digital photoplethysmography during active stand, was used to characterise OBP behaviour in the 30-110 s after standing. OH, OHTN, BPV and normal stabilisation recovery phenotypes were defined. AMD was identified following masked grading of 45° monoscopic colour retinal photographs, which were centred on the macula and taken with a NIDEK AFC-210 non-mydriatic auto-fundus camera. The relationship between OBP recovery phenotypes and AMD in 3750 adults aged ≥50 years was investigated using multivariate logistic regression models, adjusted for traditional AMD risk factors. From 30 to 110 s post active stand, systolic and diastolic OHTN was associated with increased odds of AMD after adjustment for demographics, health behaviours including smoking, family history of AMD, self-report (SR) diabetes, SR cataracts, objective hypertension and prescribed antihypertensives. No evidence of heterogeneity of OHTN effect was found between those who were hypertensive to those who were normotensive. This study provides evidence that OHTN may be an independent cardiovascular risk factor for AMD. Copyright © 2018 Elsevier Inc. All rights reserved.
Nadarajan, Balasubramanian; Krishna, Ramesh Babu; Lakshminarayanan, Subitha
2017-01-01
Introduction There is limited information on prevalence of Diabetic Retinopathy (DR) among diabetic subjects and its associated factors in a rural setting in developing countries including India. The information will be useful for initiating early screening strategies for this group in the community. Aim To assess the prevalence and certain associated factors of DR among diabetic subjects in a rural area of Tamil Nadu, India. Materials and Methods This cross-sectional study was conducted among 105 Type 2 diabetic subjects in Pakkam and Mandagapattu sub-center area of Kondur Primary Health Center in Villupuram district of Tamil Nadu, India. Data on associated factors which include sociodemographic factors, duration of disease, family history, and frequency of blood test, treatment regularity, hypertension, visual acuity and cataract were collected. Detailed eye examination including visual acuity, direct ophthalmoscope and Non Mydriatic Fundus Camera was done. Data was analysed by univariate analysis and described in proportion or percentages. Results The mean age of the study population was 56.69 years. About 47 (44.8%) of the subjects were more than 60 years of age followed by 44 subjects (41.9%) in age group 45-59 years. Fundus examination in at least one eye was seen in 83 people (79.0%). Prevalence of DR in any eye and both the eye was 32.53% (27/83) and 31.58% (24/76) respectively. Severity of DR was moderate (51.9%) followed by mild (44.4%) and severe (3.7%). DR prevalence was more among >60 years age group (p=0.032) and lesser education level (p=0.057). There was no association of DR with duration of disease, family history of diabetes, treatment regularity, presence of hypertension, visual acuity and cataract (p>0.05) Conclusion The prevalence of DR was inferred to be high and further larger follow up studies will explore the role of associated factors and its quantification in the causation of DR. PMID:28892938
Nadarajan, Balasubramanian; Saya, Ganesh Kumar; Krishna, Ramesh Babu; Lakshminarayanan, Subitha
2017-07-01
There is limited information on prevalence of Diabetic Retinopathy (DR) among diabetic subjects and its associated factors in a rural setting in developing countries including India. The information will be useful for initiating early screening strategies for this group in the community. To assess the prevalence and certain associated factors of DR among diabetic subjects in a rural area of Tamil Nadu, India. This cross-sectional study was conducted among 105 Type 2 diabetic subjects in Pakkam and Mandagapattu sub-center area of Kondur Primary Health Center in Villupuram district of Tamil Nadu, India. Data on associated factors which include sociodemographic factors, duration of disease, family history, and frequency of blood test, treatment regularity, hypertension, visual acuity and cataract were collected. Detailed eye examination including visual acuity, direct ophthalmoscope and Non Mydriatic Fundus Camera was done. Data was analysed by univariate analysis and described in proportion or percentages. The mean age of the study population was 56.69 years. About 47 (44.8%) of the subjects were more than 60 years of age followed by 44 subjects (41.9%) in age group 45-59 years. Fundus examination in at least one eye was seen in 83 people (79.0%). Prevalence of DR in any eye and both the eye was 32.53% (27/83) and 31.58% (24/76) respectively. Severity of DR was moderate (51.9%) followed by mild (44.4%) and severe (3.7%). DR prevalence was more among >60 years age group (p=0.032) and lesser education level (p=0.057). There was no association of DR with duration of disease, family history of diabetes, treatment regularity, presence of hypertension, visual acuity and cataract (p>0.05). The prevalence of DR was inferred to be high and further larger follow up studies will explore the role of associated factors and its quantification in the causation of DR.
Fan, Rong; He, Tao; Qiu, Yan; Di, Yu-Lan; Xu, Su-yun; Li, Yao-yu
2012-01-01
To evaluate the differences of wavefront aberrations under cycloplegic, scotopic and photopic conditions. A total of 174 eyes of 105 patients were measured using the wavefront sensor (WaveScan® 3.62) under different pupil conditions: cycloplegic 8.58 ± 0.54 mm (6.4 mm - 9.5 mm), scotopic 7.53 ± 0.69 mm (5.7 mm - 9.1 mm) and photopic 6.08 ± 1.14 mm (4.1 mm - 8.8 mm). The pupil diameter, standard Zernike coefficients, root mean square of higher-order aberrations and dominant aberrations were compared between cycloplegic and scotopic conditions, and between scotopic and photopic conditions. The pupil diameter was 7.53 ± 0.69 mm under the scotopic condition, which reached the requirement of about 6.5 mm optical zone design in the wavefront-guided surgery and prevented measurement error due to the pupil centroid shift caused by mydriatics. Pharmacological pupil dilation induced increase of standard Zernike coefficients Z(3)(-3), Z(4)(0) and Z(5)(-5). The higher-order aberrations, third-order aberration, fourth-order aberration, fifth-order aberration, sixth-order aberration, and spherical aberration increased statistically significantly, compared to the scotopic condition (P<0.010). When the scotopic condition shifted to the photopic condition, the standard Zernike coefficients Z(4)(0), Z(4)(2), Z(6)(-4), Z(6)(-2), Z(6)(2) decreased and all the higher-order aberrations decreased statistically significantly (P<0.010), demonstrating that accommodative miosis can significantly improve vision under the photopic condition. Under the three conditions, the vertical coma aberration appears the most frequently within the dominant aberrations without significant effect by pupil size variance, and the proportion of spherical aberrations decreased with the decrease of the pupil size. The wavefront aberrations are significantly different under cycloplegic, scotopic and photopic conditions. Using the wavefront sensor (VISX WaveScan) to measure scotopic wavefront aberrations is feasible for the wavefront-guided refractive surgery.
[A pilot study of ocular diseases screening for neonates in China].
Nie, Wen-ying; Wu, Han-rong; Qi, Yi-sheng; Zhang, Min; Hou, Qian; Yang, Hai-xia; Gong, Lu-xia; Dong, Yan-ru; Guo, Yu-luan; Shi, Jin-na; Yin, Su-ying; Li, Ping-yu
2008-06-01
To explore the clinical strategies for the screening of newborn eye diseases and obtain information concerning the incidence of newborn ocular diseases. Newborns in a baby-friendly nursery were evaluated for mass screening of eye diseases 2 to 7 days after birth (including reaction to light stimulation, external ocular examination and test for pupil red reflex) and those with abnormalities were subjected to diagnostic examination (external ocular examination with a hand-held slit-lamp, pupil red reflex and mydriatic examination). Newborns in neonatal intensive care unit (NICU) were subjected to screening 5 to 14 days after birth and then, together with those with high risk factors, received a comprehensive examination for screening and diagnostic purposes. The suspected cases were referred to department of ophthalmology for definite diagnosis. Among the 15,398 (91.65%) newborns who were enrolled the screening program, 12 different eye diseases (involving 1266 cases) were detected, with a prevalence of 8.22%. Of these eye diseases, 7 were congenital ocular diseases, involving 809 cases (5. 254%) and including congenital ptosis in 2 cases (0.013%), congenital corneal opacity in 6 cases (0.039%), persistent pupillary membrane in 724 cases (4.702%), congenital cataract in 15 cases (0.097%), persistent hyaloid artery in 54 cases (0.351%), obstruction of nasolacrimal duct in 7 cases (0.046%) and lacrimal gland prolapse in 1 cases (0.007%). Five different diseases (457 cases, 2. 968%) detected were acquired in nature, including neonatal conjunctivitis in 391 case (2.539%), vitreous hemorrhage in 6 cases (0.039%), retinal hemorrhage in 34 cases (0.221%), and neonatal dacryocystitis in 23 cases (0.149%). Of 27 premature babies with body weight lower than 1500 g, 3 had retinopathy of prematurity (ROP, 6 eyes involved). Early intervention is of great importance for the prevention and treatment of neonatal ocular diseases. The screening of newborn ocular diseases is not only feasible but also effective in the monitoring and control of the eye diseases in neonates.
Regional differences in the prevalence of diabetic retinopathy: a multi center study in Brazil.
Drummond, Karla Rezende Guerra; Malerbi, Fernando Korn; Morales, Paulo Henrique; Mattos, Tessa Cerqueira Lemos; Pinheiro, André Araújo; Mallmann, Felipe; Perez, Ricardo Vessoni; Leal, Franz Schubert Lopes; de Melo, Laura Gomes Nunes; Gomes, Marília Brito
2018-01-01
Diabetic retinopathy has a significant impact in every healthcare system. Despite that fact, there are few accurate estimates in the prevalence of DR in Brazil's different geographic regions, particularly proliferative DR and diabetic macular edema. This study aims to determine the prevalence of diabetic retinopathy in Brazil's five continental regions and its determinant factors. This multi center, cross-sectional, observational study, conducted between August 2011 and December 2014, included patients with type 1 diabetes from the 5 Brazilian geographic regions (South, Southeast, North, Northeast and Midwest). During a clinical visit, a structured questionnaire was applied, blood sampling was collected and each patient underwent mydriatic binocular indirect ophthalmoscopy evaluation. Data was obtained from 1644 patients, aged 30.2 ± 12 years (56.1% female, 54.4% Caucasian), with a diabetes duration of 15.5 ± 9.3 years. The prevalence of diabetic retinopathy was 242 (36.1%) in the Southeast, 102 (42.9%) in the South, 183 (29.9%) in the North and Northeast and 54 (41.7%) in the Midwest. Multinomial regression showed no difference in the prevalence of non-proliferative diabetic retinopathy in each geographic region, although, prevalence of proliferative diabetic retinopathy (p = 0.022), and diabetic macular edema (p = 0.003) was higher in the Midwest. Stepwise analyses reviled duration of diabetes, level of HbA1c and hypertension as independent variables. The prevalence of non proliferative diabetic retinopathy in patients with type 1 diabetes was no different between each geographic region of Brazil. The Midwest presented higher prevalence of proliferative diabetic retinopathy and diabetic macular edema. Duration of DM and glycemic control is of central importance to all. Hypertension is another fundamental factor to every region, at special in the South and Southeast. Glycemic control and patients in social and economic vulnerability deserves special attention in the North and Northeast of Brazil.
Walline, Jeffrey J
2016-01-01
Slowing the progression of myopia has become a considerable concern for parents of myopic children. At the same time, clinical science is rapidly advancing the knowledge about methods to slow myopia progression. This article reviews the peer-reviewed literature regarding several modalities attempting to control myopia progression. Several strategies have been shown to be ineffective for myopia control, including undercorrection of myopic refractive error, alignment fit gas-permeable contact lenses, outdoor time, and bifocal of multifocal spectacles. However, a recent randomized clinical trial fitted progressing myopic children with executive bifocals for 3 years and found a 39% slowing of myopia progression for bifocal-only spectacles and 50% treatment effect for bifocal spectacles with base-in prism, although there was not a significant difference in progression between the bifocal-only and bifocal plus prism groups. Interestingly, outdoor time has shown to be effective for reducing the onset of myopia but not for slowing the progression of myopic refractive error. More effective methods of myopia control include orthokeratology, soft bifocal contact lenses, and antimuscarinic agents. Orthokeratology and soft bifocal contact lenses are both thought to provide myopic blur to the retina, which acts as a putative cue to slow myopic eye growth. Each of these myopia control methods provides, on average, slightly less than 50% slowing of myopia progression. All studies have shown clinically meaningful slowing of myopia progression, including several randomized clinical trials. The most investigated antimuscarinic agents include pirenzepine and atropine. Pirenzepine slows myopia progression by approximately 40%, but it is not commercially available in the United States. Atropine provides the best myopia control, but the cycloplegic and mydriatic side effects render it a rarely prescribed myopia control agent in the United States. However, low-concentration atropine has been shown to provide effective myopia control with far fewer side effects than 1.0% atropine. Finally, two agents, low-concentration atropine and outdoor time have been shown to reduce the likelihood of myopia onset. Over the past few years, much has been learned about how to slow the progression of nearsightedness in children, but we still have a lot to learn.
Gómez-Marcos, Manuel A; Recio-Rodríguez, José I; Rodríguez-Sánchez, Emiliano; Castaño-Sánchez, Yolanda; de Cabo-Laso, Angela; Sánchez-Salgado, Benigna; Rodríguez-Martín, Carmela; Castaño-Sánchez, Carmen; Gómez-Sánchez, Leticia; García-Ortiz, Luis
2010-03-18
Diabetic patients show an increased prevalence of non-dipping arterial pressure pattern, target organ damage and elevated arterial stiffness. These alterations are associated with increased cardiovascular risk.The objectives of this study are the following: to evaluate the prognostic value of central arterial pressure and pulse wave velocity in relation to the incidence and outcome of target organ damage and the appearance of cardiovascular episodes (cardiovascular mortality, myocardial infarction, chest pain and stroke) in patients with type 2 diabetes mellitus or metabolic syndrome. This is an observational prospective study with 5 years duration, of which the first year corresponds to patient inclusion and initial evaluation, and the remaining four years to follow-up. The study will be carried out in the urban primary care setting. Consecutive sampling will be used to include patients diagnosed with type 2 diabetes between 20-80 years of age. A total of 110 patients meeting all the inclusion criteria and none of the exclusion criteria will be included. Patient age and sex, family and personal history of cardiovascular disease, and cardiovascular risk factors. Height, weight, heart rate and abdominal circumference. Laboratory tests: hemoglobin, lipid profile, creatinine, microalbuminuria, glomerular filtration rate, blood glucose, glycosylated hemoglobin, blood insulin, fibrinogen and high sensitivity C-reactive protein. Clinical and 24-hour ambulatory (home) blood pressure monitoring and self-measured blood pressure. Common carotid artery ultrasound for the determination of mean carotid intima-media thickness. Electrocardiogram for assessing left ventricular hypertrophy. Ankle-brachial index. Retinal vascular study based on funduscopy with non-mydriatic retinography and evaluation of pulse wave morphology and pulse wave velocity using the SphygmoCor system. The medication used for diabetes, arterial hypertension and hyperlipidemia will be registered, together with antiplatelet drugs. The results of this study will help to know and quantify the prognostic value of central arterial pressure and pulse wave velocity in relation to the evolution of the subclinical target organ damage markers and the possible incidence of cardiovascular events in patients with type 2 diabetes mellitus.
Komnenou, Anastasia A; Mylonakis, Mathios E; Kouti, Vassiliki; Tendoma, Lina; Leontides, Leonidas; Skountzou, Eugenia; Dessiris, Angelos; Koutinas, Alex F; Ofri, Ron
2007-01-01
To investigate the spectrum, prevalence and treatment response rate of ocular manifestations associated with natural canine monocytic ehrlichiosis (CME) due to Ehrlichia canis. The medical records of 90 dogs that were admitted for primary ocular problems and reacted positive for E. canis serum antibodies were reviewed. All the dogs were treated with oral doxycycline. In 79 dogs, a combination of systemic corticosteroids and/or topical anti-inflammatory, mydriatics/cycloplegics and antibacterial agents were applied. The dogs ranged from 0.5 to 15 years in age; 55 were male and 35 female. A total of 19 breeds were represented. In the majority of dogs, ocular abnormalities were noticed in conjunction with other CME-induced clinical signs. In 30/90 dogs, ophthalmic signs were the sole presenting complaint. Unilateral (22/90, 24.5%) and bilateral (68/90, 75.5%) uveitis was the most common ophthalmic diagnosis and was classified as anterior, posterior or panuveitis in 58 (64.5%), 8 (8.9%) and 24 (26.6%) of the dogs, respectively. Bilateral uveitis was significantly more common than unilateral uveitis (P < 0.0001), and anterior significantly more common than posterior uveitis (P < 0.0001) or panuveitis (P < 0.0001). In addition, corneal ulceration (12/90, 13.3%), necrotic scleritis (10/90, 11.1%), low tear production (8/90, 8.9%) and orbital cellulitis (3/90, 3.3%) were seen. Of the 45 (50%) dogs with a satisfactory follow-up, 25 (55.5%), 11 (24.5%), and 9 (20%) showed complete, partial and poor response to treatment, respectively. The number of dogs exhibiting complete resolution of the ocular manifestations was significantly higher than those with partial (P < 0.0001) or poor (P < 0.0001) response. CME should be considered a major differential for a wide range of ocular manifestations exhibited by dogs residing in the endemic areas of the disease. Anterior bilateral uveitis appears to be the most prevalent ocular lesion and a favorable outcome to systemic and topical treatment may be expected in the majority of the affected dogs.
Friedman, Matt S; Plocki, Alex; Likourezos, Antonios; Pushkar, Illya; Bazos, Andrew N; Fromm, Christian; Friedman, Benjamin W
2017-02-01
Mass-Gathering Medicine studies have identified variables that predict greater patient presentation rates (PPRs) and transport to hospital rates (TTHRs). This is a descriptive report of patients who presented for medical attention at an annual electronic dance music festival (EDMF). At this large, single EDMF in New York City (NYC; New York, USA), the frequency of patient presentation, the range of presentations, and interventions performed were identified. This descriptive report examined consecutive patients who presented to the medical tent of a summertime EDMF held at an outdoor venue with an active, mobile, bounded crowd. Alcohol was available for sale. Entry was restricted to persons 18 years and older. The festival occurred on three consecutive days with a total cumulative attendance of 58,000. Medical staffing included two Emergency Medicine physicians, four registered nurses, and 86 Emergency Medical Services (EMS) providers. Data collected included demographics, past medical history, vital signs, physical exam, drug and alcohol use, interventions performed, and transport decisions. Eighty-four patients were enrolled over 2.5 days. Six were transported and zero died. The ages of the subjects ranged from 17 to 61 years. Forty-three (51%) were male. Thirty-eight (45%) initially presented with abnormal vital signs; four (5%) were hyperthermic. Of these latter patients, 34 (90%) reported ingestions with 3,4-methylenedioxymethamphetamine (MDMA) or other drugs. Eleven (65%) patients were diaphoretic or mydriatic. The most common prehospital interventions were intravenous normal saline (8/84; 10%), ondansetron (6/84; 7%), and midazolam (3/84; 4%). Electronic dance music festivals are a growing trend and a new challenge for Mass-Gathering Medicine as new strategies must be employed to decrease TTHR and mortality. Addressing common and expected medical emergencies at mass-gathering events through awareness, preparation, and early, focused medical interventions may decrease PPR, TTHR, and overall mortality. Friedman MS , Plocki A , Likourezos A , Pushkar I , Bazos AN , Fromm C , Friedman BW . A prospective analysis of patients presenting for medical attention at a large electronic dance music festival. Prehosp Disaster Med. 2017; 32(1):78-82.
Bursell, Sven-Erik; Fonda, Stephanie J; Lewis, Drew G; Horton, Mark B
2018-01-01
Diabetes and its complications are more common in American Indians and Alaska Natives (AI/AN) than other US racial/ethnic populations. Prior reports of diabetic retinopathy (DR) prevalence in AI/AN are dated, and research on diabetic macular edema (DME) is limited. This study characterizes the recent prevalence of DR and DME in AI/AN using primary care-based teleophthalmology surveillance. This is a multi-site, clinic-based, cross-sectional study of DR and DME. The sample is composed of AI /AN patients with diabetes (n = 53,998), served by the nationally distributed Indian Health Service-Joslin Vision Network Teleophthalmology Program (IHS-JVN) in primary care clinics of US Indian Health Service (IHS), Tribal, and Urban Indian health care facilities (I/T/U) from 1 November 2011 to 31 October 2016. Patients were recruited opportunistically for a retinal examination using the IHS-JVN during their regular diabetes care. The IHS-JVN used clinically validated, non-mydriatic, retinal imaging and retinopathy assessment protocols to identify the severity levels of non-proliferative diabetic retinopathy (NPDR), proliferative diabetic retinopathy (PDR), DME, and sight threatening retinopathy (STR; a composite measure). Key social-demographic (age, gender, IHS area), diabetes-related health (diabetes therapy, duration of diabetes, A1c), and imaging technology variables were examined. The analysis calculated frequencies and percentages of severity levels of disease. Prevalence of any NPDR, PDR, DME, and STR among AI/AN patients undergoing DR teleophthalmology surveillance by IHS-JVN was 17.7%, 2.3%, 2.3%, and 4.2%, respectively. Prevalence was lowest in Alaska and highest among patients with A1c >/ = 8%, duration of diabetes > 10 years, or using insulin. Prevalence of DR in this cohort was approximately half that in previous reports for AI/AN, and prevalence of DME was less than that reported in non-AI/AN populations. A similar reduction in diabetes related end-stage renal disease in the same population and time period has been reported by other researchers. Since these two diabetic complications share a common microvasculopathic mechanism, this coincident change in prevalence may also share a common basis, possibly related to improved diabetes management.
2010-01-01
Background Diabetic patients show an increased prevalence of non-dipping arterial pressure pattern, target organ damage and elevated arterial stiffness. These alterations are associated with increased cardiovascular risk. The objectives of this study are the following: to evaluate the prognostic value of central arterial pressure and pulse wave velocity in relation to the incidence and outcome of target organ damage and the appearance of cardiovascular episodes (cardiovascular mortality, myocardial infarction, chest pain and stroke) in patients with type 2 diabetes mellitus or metabolic syndrome. Methods/Design Design: This is an observational prospective study with 5 years duration, of which the first year corresponds to patient inclusion and initial evaluation, and the remaining four years to follow-up. Setting: The study will be carried out in the urban primary care setting. Study population: Consecutive sampling will be used to include patients diagnosed with type 2 diabetes between 20-80 years of age. A total of 110 patients meeting all the inclusion criteria and none of the exclusion criteria will be included. Measurements: Patient age and sex, family and personal history of cardiovascular disease, and cardiovascular risk factors. Height, weight, heart rate and abdominal circumference. Laboratory tests: hemoglobin, lipid profile, creatinine, microalbuminuria, glomerular filtration rate, blood glucose, glycosylated hemoglobin, blood insulin, fibrinogen and high sensitivity C-reactive protein. Clinical and 24-hour ambulatory (home) blood pressure monitoring and self-measured blood pressure. Common carotid artery ultrasound for the determination of mean carotid intima-media thickness. Electrocardiogram for assessing left ventricular hypertrophy. Ankle-brachial index. Retinal vascular study based on funduscopy with non-mydriatic retinography and evaluation of pulse wave morphology and pulse wave velocity using the SphygmoCor system. The medication used for diabetes, arterial hypertension and hyperlipidemia will be registered, together with antiplatelet drugs. Discussion The results of this study will help to know and quantify the prognostic value of central arterial pressure and pulse wave velocity in relation to the evolution of the subclinical target organ damage markers and the possible incidence of cardiovascular events in patients with type 2 diabetes mellitus. Trial Registration ClinicalTrials.gov Identifier: NCT01065155 PMID:20298558
Ocular medicines in children: the regulatory situation related to clinical research
2012-01-01
Background Many ocular medications are prescribed for paediatric patients, but the evidence for their rational use is very scant. This study was planned to compare the availability and the licensing status of ocular medications marketed in Italy, the United Kingdom (UK), and the United States of America (USA) related to the amount of published and un-published RCTs testing these drugs in the paediatric population. Methods A quantitative analysis was performed to evaluate the number of ocular medications with a paediatric license in Italy, the UK, and the USA. A literature search was also performed in MEDLINE, EMBASE, and The Cochrane Central Register of Controlled Trials for randomized controlled trials (RCTs) on ophthalmic pharmacological therapy in children aged < 18 years, published up to December 2010. A search in the international clinical trial registries, the list of paediatric investigation plans (PIPs) approved by European Medicines Agency (EMA), and the table of medicines with new paediatric information approved by Food and Drug Administration (FDA) was also performed. Results In all, of 197 drugs identified, 68 (35%) single drugs are licensed for paediatric use at least in one considered country, while 23 (12%) were marketed in all three countries. More specifically, in Italy 43 single drugs (48% of those marketed) had a paediatric license, while 39 (64%) did in the UK and 22 (54%) did in the USA. Only 13 drugs were marketed with a paediatric license in all countries. The percentage of drugs licensed for paediatric use and for which at least one RCT had been performed ranged between 51% in Italy and 55% in the USA. No published RCTs were found for 11 (48%) drugs licensed for paediatric use in all three countries. In all, 74 (35%) of the retrieved RCTs involved mydriatic/cycloplegic medications. A total of 62 RCTs (56% completed) on 46 drugs were found in the international clinical trial registries. Cyclosporin and bevacizumab were being studied in many ongoing trials. Twenty-six drugs had new paediatric information approved by FDA based on new paediatric clinical trials, while only 4 PIPs were approved by EMA. Conclusions There is a pressing need for further research and clinical development in the pediatric ophthalmic area, where effective up-to-date treatments, and additional research and education on use in children, remain priorities. PMID:22264311
alpha(2)-adrenoceptor antagonist properties of OPC-28326, a novel selective peripheral vasodilator.
Orito, K; Kishi, M; Imaizumi, T; Nakazawa, T; Hashimoto, A; Mori, T; Kambe, T
2001-10-01
1. Antagonistic properties of OPC-28326 ([4-(N-methyl-2-phenylethylamino)-1-(3,5-dimethyl-4-propionyl-aminobenzoyl)] piperidine hydrochloride monohydrate), a selective peripheral vasodilator, were investigated by analysing the data from functional studies in various tissues from the rat and binding studies of the drug to alpha(2)-adrenoceptor subtypes. 2. Using a human recombinant receptor and rat kidney cortex, we found that OPC-28326 displays affinities to alpha(2A)-, alpha(2B)- and alpha(2C)-adrenoceptors with K(i) values of 2040, 285, and 55 nM, respectively. The K(i) values of yohimbine for alpha(2A)-, alpha(2B)-, and alpha(2C)-adrenoceptors were 3.0, 2.0 and 11.0 nM, respectively. 3. B-HT 920, an alpha(2)-adrenoceptor agonist, produced a pressor response via peripheral postsynaptic alpha(2)-adrenoceptor stimulation (thought to be an alpha(2B)-subtype) in a reserpine-pretreated pithed rat preparation. OPC-28326 (3 - 30 mg kg(-1), i.v.) and yohimbine (0.3 - 3 mg kg(-1), i.v.) caused dose-dependent rightward shift in the pressor dose-response curve induced by B-HT 920. The apparent pA(2) values were 1.55 (0.87 - 2.75, 95% confidence interval) and 0.11 (0.06 - 0.21) mg kg(-1), respectively. The potency of OPC-28326 was about 14 times less than that of yohimbine. 4. Clonidine inhibited the tension developed by electrical stimulation, of the rat vas deferens, by its peripheral presynaptic alpha(2A/D)-adrenoceptor action. OPC-28326 (1 - 100 microM) and yohimbine (10 - 1000 nM) caused a rightward shift in the concentration-response curve of clonidine. The pA(2) values were 5.73 (5.54 - 5.91) and 7.92 (7.84 - 8.01), respectively, providing evidence for a potency of OPC-28326 of about 155 times less than that of yohimbine. 5. Mydriasis was induced by brimonidine via stimulation of central alpha(2A/D)-adrenoceptors in anaesthetized rats. Intravenous OPC-28326 had no effect on this action, even at a very high dose of 10 mg kg(-1) i.v., while yohimbine (0.1 - 0.3 mg kg(-1) i.v.) inhibited mydriasis in a dose-dependent manner, indicating that OPC-28326 was at least 100 times less potent than yohimbine in regard to the anti-mydriatic effect. 6. These data suggest that OPC-28326 preferentially exerts peripheral and postsynaptic antagonistic actions on the alpha(2B)- and alpha(2C)-adrenoceptor subtypes.
Islam, Fakir M Amirul
2017-01-01
To evaluate the accuracy and reliability of fundus retinal photos graded by local graders in Bangladesh with those graded by an expert at the Centre for Eye Research Australia (CERA) in the context of mass scale diabetic retinopathy (DR) screening in Bangladesh. A population-based cross-sectional study of 3,104 adults identified 213 (7.2%) eligible patients with diabetes of age ≥ 40 years in 2012-2013. Retinal photographs were collected using a non-mydriatic digital fundus retinal camera and a two-field imaging protocol. The photos were graded by two remote graders (G1 and G2) who were trained by a retinal specialist (RS) in Bangladesh, by the RS himself, and by a Centre for Eye Research Australia (CERA) grader. The local graders up skilled their grading ability by comparing 30% of the photos graded by the CERA grader with their own grades. Learning from that exercise was applied to the remaining 70% of photos, which were re-graded. Reliability and accuracy of grading amongst the graders were reported using cross tabulation, inter- and intra-grader reliability, and with sensitivity and specificity. Of 122 eyes from 61 patients, the mild (R1) DR was estimated to be 14 to 25%, pre-proliferative (R2) DR 4-8%, and proliferative (R3) DR 0.8 to 1.6%, whereas 25%, 8%, 18%, and 15% were found to be ungradable by CERA, RS, G1, and G2, respectively. Of 8 (6.6%) eyes identified as R2 by the CERA grader, 5 (63%), 3 (38%) and 3 (38%) were correctly classified as R2, whereas the rest were classified either as R1 or R3 but none were classified as no DR (R0) or ungradable by the RS, G1 and G2, respectively. After getting experience reviewing the 30% test set graded by the CERA grader, the local graders graded moderate and severe DR with 100% accuracy. After excluding ungradable photos, the sensitivity (specificity) relative to the CERA grader was 82% (88%) before and 80% (93%) after training for G1 and 56% (87%) before and 77% (90%) after training for G2. In case of maculopathy, the CERA grader reported 11.2% eyes with maculopathy, which included 100% of the 4.9% by RS, 6.6% by G1, and 7.4% by G2. Local graders in Bangladesh are able to grade retinal photos with high accuracy if the DR is at least of a moderate level. With appropriate training and experience, local graders have the ability to contribute significantly to the grading of millions of retinal photos, which required grading in resource- poor countries.
NASA Astrophysics Data System (ADS)
Addo, Richard Tettey
Designing formulations for ophthalmic drug delivery is one of the most challenging endeavors facing the pharmaceutical scientist due to the unique anatomy, physiology, and biochemistry of the eye. Current treatment protocols for administration of drugs in eye diseases are primarily solution formulations, gels or ointments. However, these modes of delivery have several drawbacks such as short duration of exposure, need for repeated administrations and non-specific toxicity. We hypothesize that development of ocular drugs in microparticles will overcome the deficiencies of the current modalities of treatment. We based the hypothesis on the preliminary studies conducted with encapsulated tetracaine, an anesthetic used for surgical purposes and atropine, a medication used for several ophthalmic indications including mydriatic and cycloplegic effects. However, atropine is well absorbed into the systemic circulation and has been reported to exert severe systemic side effects after ocular administration (Hoefnagel D. 1961, Morton H. G. 1939 and Lang J. C. 1995) and may lead to serious side effects including death in extreme cases with pediatric use. Based on these observations, the focus of this dissertation is to formulate microparticulate drug carrier for treatment of various conditions of the eye. Purpose: To prepare, characterize, study the in vitro and in vivo interaction of albumin-chitosan microparticles (BSA-CSN MS), a novel particulate drug carrier for ocular drug delivery. Method: Microparticle formulations were prepared by method of spray drying. The percentage drug loading and efficiency were assessed using USP (I) dissolution apparatus. Using Malvern Zeta-Sizer, we determined size and surface charge of the fabrication. Surface morphology of the microparticles was examined using Scanning Electron Microscopy. Microparticles were characterized in terms of thermal properties using Differential Scanning Calorimetry. Human corneal epithelial cells (HCET-1) were exposed up to 120 minutes to different BSA-CSN MS concentrations. Using fluorometry, the influence of temperature and effect of metabolic inhibition were studied. The in vitro uptake and internalization studies were evaluated using confocal microscopy in HCET-1. In vivo studies were evaluated in rabbit's eye using blink response and pupil to cornea ratio for tetracaine and atropine studies respectively. Results: Our results showed particles size in the range of 3-5 microns with encapsulation efficiency of about 96 percent. Differential Scanning Calorimetry showed no drug-polymer interactions. BSA-CSN MS were internalized by the HCET-1 and was affected both by temperature and metabolic inhibitor, sodium azide. There were no signs of ocular surface toxicity or inflammation. The encapsulated drugs exhibited superior properties in vivo compared to the solution formulations currently in clinical use. Conclusion: We successfully developed microparticulate drug carriers for ocular delivery. BSA-CSN MS were internalized by the HCET-1 by temperature dependent active transport mechanism that did not compromise cell viability.
[21st century management of glaucoma].
Tsukahara, Shigeo
2003-12-01
According to a recent epidemiological study done in Japan, 2 or 3 million Japanese people are thought to be suffering from glaucoma, and 70-80% of them have not been examined or diagnosed by ophthalmologists. Therefore, the problem is how to find these untreated and undiagnosed people. At present, treatment of glaucoma continues to be directed at lowering intraocular pressure to prevent progression of glaucomatous optic neuropathy. However, theoretically, there are three stages in the prevention of progression of glaucoma. In the first stage, diagnosis of glaucoma can be done by genetic examination, before occurrence of glaucoma. The MYOCILIN/trabecular meshwork-inducible glucocorticoid response gene and the optineurin gene were identified as the genes that cause open angle glaucoma. Although some Japanese patients have sequence changes in the myocilin gene, there are no apparent specific mutations in Japanese glaucoma patients, in the MYOCILIN/TIGR and optineurin genes. Secondary glaucoma such as steroid glaucoma, induced by allergic diseases, and neovascular glaucoma, induced by retinal circulatory insufficiency, are preventable by improving the causal diseases, diabetes and hypertension. The education of doctors and laymen is important to reduce the occurrence of diabetes, and hypertension to prevent diabetic retinopathy, and retinal vessel occlusion. The second stage in preventing progression of glaucoma is to find the disease as early as possible. In Japan, a physical examination system is in place for everybody over 40 years old, in companies and local districts. Therefore, ocular examination, specially non-mydriatic fundus photographs should be taken in these examinations, and the film should be evaluated by an ophthalmologist, to search for retinal and optic disc abnormalities. Primary open angle glaucoma can be detected through this system in early stages. In primary angle closure glaucoma, instruments for estimating anterior chamber rapidly and accurately are necessary for the diagnosis. There is a special machine which can be handled easily, safely, and economically for detecting angle closure glaucoma, has been developed by Yamanashi University. This machine might help to reduce the number of angle closure glaucoma patients in the world. In the near future, a glaucoma network system should be put in place all over Japan. This organization consists of central headquarter and local central office. Most hospitals and private offices will belong to a local central office, and several glaucoma specialists will work in central and local offices. All glaucoma patients will be registered in local glaucoma office. The information on glaucoma patients will be communicated in the system the through light fiber cables or a satellite system. The patients can ask about their own disease through this glaucoma center system. In the third stage of glaucoma prevention, progression of glaucomatous optic neuropathy is retarded by conventional IOP lowering treatment or neuroprotective drugs. This stage compromises rehabilitation of visual function, implant of artificial visual systems, and regeneration of retinal ganglion cells(RGC). The disturbances of axonal flow in guinea pig optic nerve fibers was demonstrated electromicroscopically by quick-freeze, deep-etching method and, the decrease in numbers of motor proteins like "Kinesin" "Dynein" and "MAP-1" was shown in guinea pig eyes with elevated intraocular pressure by immunohistochemistry. Retinal glanglion cells have been isolated and new findings have been reported using this RGC culture system. Therefore, new neuroprotective drugs will be developed through this culture system.
[Clinical and paraclinical features of syphilitic uveitis].
Marty, A-S; Cornut, P-L; Janin-Manificat, H; Perard, L; Debats, F; Burillon, C
2015-03-01
Syphilis, caused by Treponema pallidum agent, results in polymorphic and non-specific ocular manifestations. Early diagnosis and institution of individualized treatment play a large role in the prognosis. The increase in syphilis over the past several years requires the ophthalmologist to consider this diagnosis in the setting of any intraocular inflammatory involvement. To describe epidemiological, clinical and paraclinical features and natural history of syphilitic uveitis. Retrospective, descriptive and non-comparative study of a series of patients hospitalized between 2007 and 2013 in our department of ophthalmology for management of ocular inflammation associated with a positive syphilitic serology. Thirteen patients of mean age 52.5 years ± 12.9 (33-82 years) were included. All were male and were followed for six months. Co-infection with human immunodeficiency virus (HIV) was present in four of them. Other risk factors discovered on history were unprotected sexual relations, multiple partners, homosexual relations, co-infection with another sexually transmitted disease (STD) or an occupational risk. Decreased visual acuity (VA) was present in all patients, with an average initial VA of 0.71 ± 0.81 LogMAR, i.e. 2/10. Involvement was bilateral in 38% (n=5) of cases. Papilledema was present in 10 patients. Seven patients exhibited vasculitis, 6 patients a necrotizing retinitis, 2 patients with placoid lesions, 7 patients with panuveitis and 2 patients with macular edema. We did not find any patients with isolated anterior uveitis. Three patients exhibited concomitant extraocular involvement with cutaneous palmoplantar lesions. Spectral domain optical coherence tomography (SD-OCT) found a fragmentation of the external limiting membrane and a disorganization of the ellipsoid line in two patients. Cerebrospinal fluid was studied for all patients. Eight of them exhibited lymphocytic meningitis, and we found the presence of anti-Treponema pallidum hemagglutination assay antibody (TPHA) in 9 patients and anti-veneral disease research laboratory antibody (VDRL) in 1 patient. Syphilis polymerase chain reaction (PCR) in the aqueous humor was positive in 50% (n=6) of studied cases and the PCR for Epstein Barr virus came back positive in four specimens out of eight. False positive reactions were observed for Lyme disease in eight patients. The four HIV-positive patients showed bilateral lesions more frequently, but less severe and with a favorable outcome. Antibiotic treatment with ceftriaxone (2 grams per day intramuscularly for 15 to 21 days) and local treatment (corticoids and mydriatics) in the case of inflammation of the anterior segment, allowed a regression of the inflammation in all of our patients as well as an improvement in VA (average final VA 0.09 ± 0.17 LogMAR, i.e. approximately 8/10). One Jarisch Herxheimer reaction occurred and was resolved with systemic corticosteroid therapy. A change in the retinal pigment epithelium was the main sequela in 44% of cases (n=8 eyes). Every structure of the eye may be involved with syphilis; therefore, syphilis must be systematically sought during the etiologic assessment of ocular inflammation even in the absence of historical risk factors. HIV-positive patients must be handled in the same way as immunocompetent patients. Collaboration with the internist is essential for the diagnosis, monitoring, and staging, especially in search of neurosyphilis. The clinical course is favorable with early treatment. Crown Copyright © 2014. Published by Elsevier Masson SAS. All rights reserved.