Sample records for n-butyl cyanoacrylate glue

  1. Endovascular embolization of varicoceles using n-butyl cyanoacrylate (NBCA) glue

    PubMed Central

    Pietura, Radosław; Toborek, Michał; Dudek, Aneta; Boćkowska, Agata; Janicka, Joanna; Piekarski, Paweł

    2013-01-01

    Summary Background: Varicoceles are abnormally dilated veins within the pampiniform plexus. They are caused by reflux of blood in the internal spermatic vein. The incidence of varicoceles is approximately 10–15% of the adolescent male population. The etiology of varicoceles is probably multifactorial. The diagnosis is based on Doppler US. Treatment could be endovascular or surgical. The aim of the study was to describe and evaluate a novel method of endovascular embolization of varicoceles using n-butyl cyanoacrylate (NBCA) glue. Material/Methods: 17 patients were subjected to endovascular treatment of varicoceles using NBCA. A 2.8 Fr microcatheter and a 1:1 mixture of NBCA and lipiodol were used for embolization of the spermatic vein. Results: All 17 procedures were successful. There were no complications. Discussion: Embolization of varicoceles using NBCA glue is efficient and safe for all patients. The method should be considered as a method of choice in all patients. Phlebography and Valsalva maneuver are crucial for technical success and avoidance of complications. Conclusions: Endovascular treatment of varicoceles using NBCA glue is very effective and safe. PMID:23807881

  2. N-butyl cyanoacrylate embolotherapy: techniques, complications, and management

    PubMed Central

    Hill, Hannah; Chick, Jeffrey Forris Beecham; Hage, Anthony; Srinivasa, Ravi N.

    2018-01-01

    The purpose of this article is to describe acute complications associated with adhesive cyanoacrylate deposition in the peripheral circulation and their management. Despite best efforts, n-butyl cyanoacrylate glue embolization is inherently unpredictable and complications do occur. An understanding of preparation techniques that minimize adverse event rates and the technical skillset required to manage complications are necessary for the safe and efficient use of liquid embolic agents. PMID:29467116

  3. Compression properties and dissolution of bioactive glass S53P4 and n-butyl-2 cyanoacrylate tissue adhesive-composite.

    PubMed

    Sarin, Jussi; Hiltunen, Markus; Hupa, Leena; Pulkkinen, Jaakko; Vallittu, Pekka K

    2016-09-28

    Bioactive glass (BG)-containing fiber-reinforced composite implants, typically screw-retained, have started to be used clinically. In this study, we tested the mechanical strength of composites formed by a potential implant adhesive of n-butyl-2-cyanoacrylate glue and BG S53P4 particles. Water immersion for 3, 10 or 30 days had no adverse effect on the compression strength. When cyanoacrylate glue-BG-composites were subjected to simulated body fluid immersion, the average pH rose to 7.52 (SD 0.066) from the original value of 7.35 after 7 days, and this pH increment was smaller compared to BG particle-group or fibrin glue-BG-composite group. Based on these results n-butyl-2 cyanoacrylate glue, by potentially producing a strong adhesion, might be considered a possible alternative for fixation of BG S53P4 containing composite implants. However, the mechanical and solubility properties of the cyanoacrylate glue may not encourage the use of this tissue adhesive with BG particles.

  4. Cystoscopic injection of N-butyl-2-cyanoacrylate followed by fibrin glue for the treatment of persistent or massive vesicourethral anastomotic urine leak after radical prostatectomy.

    PubMed

    Lim, Ju Hyun; You, Dalsan; Jeong, In Gab; Park, Hyung Keun; Ahn, Hanjong; Kim, Choung-Soo

    2013-10-01

    Vesicourethral anastomotic urine leak is a common postoperative complication of radical prostatectomy. Herein we describe a novel method for the treatment of this complication. Intervention for a prolonged or massive anastomotic urine leak was required in 10 out of 1828 patients (0.5%) submitted to radical prostatectomy between 2007 and 2011. N-butyl-2-cyanoacrylate (Histoacryl) followed by fibrin glue (Greenplast) were injected under local anesthesia into vesicourethral anastomotic gaps under fluoroscopic guidance using a 20-Fr rigid cystoscope. Cystograms were taken in all patients to confirm complete urine leak resolution before the removal of the urethral catheter. Cystoscopic injection of Histoacryl followed by fibrin glue was technically successful and well tolerated in all patients. The mean time from radical prostatectomy to glue injection was 16.0 days (range 12-27 days). Urethral catheterization was required for an average of 7.7 days after cystoscopic injection of fibrin glue (range 3-13 days). These measures ultimately enabled complete resolution of the urine leak in all cases. At a mean follow up of 23.3 months, all 10 patients were fully continent. The mean time to recovery of urinary continence was 20.4 weeks (range 3.9-60.0 weeks). Cystoscopic injection of N-butyl-2-cyanoacrylate followed by fibrin glue into the anastomotic gap is both a feasible and effective solution in patients with a persistent or massive vesicourethral anastomotic urine leak after radical prostatectomy. © 2013 The Japanese Urological Association.

  5. Rescue N-butyl-2 cyanoacrylate embolectomy using a Solitaire FR device after venous glue migration during arteriovenous malformation embolization: technical note.

    PubMed

    Fahed, Robert; Clarençon, Frédéric; Sourour, Nader-Antoine; Chauvet, Dorian; Le Jean, Lise; Chiras, Jacques; Di Maria, Federico

    2016-07-01

    One of the procedural risks in arteriovenous malformation (AVM) embolization is possible migration of the embolic agent into the venous drainage with an incomplete nidus occlusion, which may lead to severe hemorrhagic complications. This report presents the case of a 29-year-old man who presented with a deep intraparenchymal hematoma on the left side secondary to the spontaneous rupture of a claustral AVM. Upon resorption of the hematoma, the patient underwent an initial therapeutic session of N-butyl-2 cyanoacrylate endovascular embolization, with the purpose of reducing the AVM volume and flow before performing Gamma Knife radiosurgery. After glue injection into one of the arterial feeders, the control angiography showed a partial migration of the glue cast into the straight sinus, with most of the nidus still visible. Because of the bleeding risk due to possible venous hypertension, it was decided to try to retrieve the glue from the vein by using a stent retriever via jugular access. This maneuver allowed a nearly complete removal of the glue cast, thereby restoring normal venous flow drainage. The patient showed no clinical worsening after the procedure. To the authors' knowledge, this is the first report of the use of the Solitaire FR device as a rescue glue retriever. This method should be considered by physicians in cases of unintended glue migration into the venous circulation during AVM embolization.

  6. Embolization of congenital intrahepatic porto-systemic shunt by n-butyl cyanoacrylate.

    PubMed

    Gupta, Vivek; Kalra, Naveen; Vyas, Sameer; Sodhi, K S; Thapa, B R; Khandelwal, N

    2009-10-01

    Congenital intrahepatic portosystemic venous shunt (IHPSVS) is rare vascular anomaly. We present one case of a 14-month male child who presented with global developmental delay. Child had high ammonia levels with low glutamine and high bile salts on the previous investigations and had history of neonatal seizures since day 13 of life. On admission, serum ammonia levels were elevated to 112micromol/L. Other laboratory investigations including liver and renal function test, and electrolytes were normal. He was, diagnosed to have IHPSVS on the basis of Doppler and CT, and treated by embolization with n-butyl cyanoacrylate (glue). A brief review of diagnostic modalities and endovascular management for the IHPSVS is presented including the present case.

  7. Preoperative Embolization of Venous Malformations Using n-Butyl Cyanoacrylate.

    PubMed

    Uller, Wibke; El-Sobky, Sherif; Alomari, Ahmad I; Fishman, Steven J; Spencer, Samantha A; Taghinia, Amir H; Chaudry, Gulraiz

    2018-05-01

    The purpose of this study was to evaluate the safety and efficacy of preoperative percutaneous n-butyl cyanoacrylate (nBCA) embolization of venous malformations in children. Clinical data were retrospectively reviewed in children who underwent embolization using nBCA followed by resection of venous malformations. A total of 17 embolizations were performed in 14 patients (9 females, mean age: 5.5 years; median age: 3 years; range 0.1-16 years). The venous malformations involved the lower extremity and the knee joint (n = 7), the trunk (n = 4), head and neck (n = 2), and hand (n = 1). n-Butyl cyanoacrylate was diluted with iodized oil at a ratio of 1:3 to 1:5. The mean and median volume of nBCA per procedure were 2.1 and 2 mL, respectively (range: 0.5-8 mL). There were no complications associated with the procedures. The mean and median time between final embolization and resection were 3.6 and 2 days, respectively. All children underwent successful resection of the symptomatic lesions. The estimated mean and median blood loss were 75 and 50 mL, respectively (range: 5-350 mL). The postprocedure course was uneventful, the days to discharge ranged between 1 and 6 days (mean 3 days). Initial results suggest that preoperative percutaneous n-butyl cyanoacrylate embolization of venous malformations is safe and effective in children, with the potential for minimizing blood loss and inpatient stay.

  8. Double-Balloon-Assisted n-Butyl-2-Cyanoacrylate Embolization of Intrahepatic Arterioportal Shunt Prior to Chemoembolization of Hepatocellular Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takao, Hidemasa, E-mail: takaoh-tky@umin.ac.jp; Shibata, Eisuke; Ohtomo, Kuni

    A case of multiple hepatocellular carcinomas with a severe intrahepatic arterioportal shunt that was successfully embolized with n-butyl-2-cyanoacrylate with coaxial double-balloon occlusion prior to transcatheter arterial chemoembolization is presented. A proximal balloon positioned at the proper hepatic artery was used for flow control, and a coaxial microballoon, positioned in the closest of three arterial feeding branches to the arterioportal shunt, was used to control the delivery of n-butyl-2-cyanoacrylate. This coaxial double-balloon technique can prevent proximal embolization and distal migration of n-butyl-2-cyanoacrylate and enable precise control of the distribution of n-butyl-2-cyanoacrylate. It could also be applicable to n-butyl-2-cyanoacrylate embolization for othermore » than intrahepatic arterioportal shunt.« less

  9. Use of cyanoacrylate glue for temporary tarsorrhaphy in children.

    PubMed

    Trivedi, Dipti; McCalla, Maureen; Squires, Zoe; Parulekar, Manoj

    2014-01-01

    Congenital anophthalmia and postenucleation socket contracture are difficult conditions that require serial socket expansion with the use of hydrogel expanders and custom-made conformers along with temporary tarsorrhaphy. The authors undertook a part prospective case review of all children undergoing temporary tarsorrhaphy using cyanoacrylate glue over a 3-year period at a tertiary specialist children's hospital. They report a series of 7 children undergoing temporary tarsorrhaphy with cyanoacrylate glue instead of the conventional suturing technique. Indications were socket expansion (n = 4), fornix deepening (n = 2), prosthesis reposition, and prolapsed conjunctiva following enucleation (n = 1).The age range was 3 weeks to 14 years (mean, 2.7 years). The glue tarsorrhaphy lasted between 0.5 and 13 weeks (mean, 4.5 weeks). There were no adverse outcomes, and the glue tarsorrhaphy was tolerated well in all cases, with relative ease of reapplication of glue in clinic. Their study demonstrates that this technique allows quick and efficient temporary tarsorrhaphy with relative ease of reapplication in a clinic setting, avoiding the need for multiple general anesthetics.

  10. Therapeutic ureteral occlusion with Ifabond cyanoacrylate glue: an interesting solution.

    PubMed

    Oderda, Marco; Lacquaniti, Sergio; Fraire, Flavio; Antolini, Jacopo; Camilli, Marco; Mandras, Roberto; Puccetti, Luca; Varvello, Francesco; Fasolis, Giuseppe

    2017-08-01

    The aim of this study was to present a novel approach for complete and permanent ureteral occlusion using a percutaneous injection of Ifabond cyanoacrylate glue. We describe in detail all the steps of our surgery, performed on a 79-year-old patient with urinary leakage from ureteral stump following radical cystectomy. N-hexyl-cyanoacrylate glue (Ifabond) was used to occlude the distal ureter and solve the leakage. Our approach was successful, sparing our already frail patient further surgical procedures. Six months pyelography confirmed the complete ureteral blockage with absence of extravasation. In complicated scenarios with urinary leakages and frail patients, synthetic glues such as Ifabond might represent an interesting therapeutic option to solve the fistulas, leading to durable success with a minimally invasive approach.

  11. Cyanoacrylate medical glue application in intervertebral disc annulus defect repair: Mechanical and biocompatible evaluation.

    PubMed

    Kang, Ran; Li, Haisheng; Lysdahl, Helle; Quang Svend Le, Dang; Chen, Menglin; Xie, Lin; Bünger, Cody

    2017-01-01

    In an attempt to find an ideal closure method during annulus defect repair, we evaluate the use of medical glue by mechanical and biocompatible test. Cyanoacrylate medical glue was applied together with a multilayer microfiber/nanofiber polycaprolactone scaffold and suture in annulus repair. Continuous axial loading and fatigue mechanical test was performed. Furthermore, the in vitro response of mesenchymal stem cell (MSC) to the glue was evaluated by cell viability assay. The in vivo response of annulus tissue to the glue and scaffold was also studied in porcine lumbar spine; histological sections were evaluated after 3 months. Cyanoacrylate glue significantly improved the closure effect in the experimental group with failure load 2825.7 ± 941.6 N, compared to 774.1 ± 281.3 N in the control group without glue application (p < 0.01). The experimental group also withstood the fatigue test. No toxic effect was observed by in vitro cell culture and in vivo implantation. On the basis of this initial evaluation, the use of cyanoacrylate medical glue improves closure effect with no toxicity in annulus defect repair. This method of annulus repair merits further effectiveness study in vivo. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 14-20, 2017. © 2015 Wiley Periodicals, Inc.

  12. Recanalization of Splenic Artery Aneurysm After Transcatheter Arterial Embolization Using N-Butyl Cyanoacrylate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsumoto, Keiji; Ushijima, Yasuhiro, E-mail: ushijima@radiol.med.kyushu-u.ac.jp; Tajima, Tsuyoshi

    2010-02-15

    A 65-year-old woman who had been diagnosed as having microscopic polyangiitis developed sudden abdominal pain and entered a state of shock. Abdominal CT showed massive hemoperitoneum, and emergent angiography revealed a ruptured splenic artery aneurysm. After direct catheterization attempts failed due to tortuous vessels and angiospasm, transcatheter arterial embolization using an n-butyl cyanoacrylate (NBCA)-lipiodol mixture was successfully performed. Fifty days later, the patient developed sudden abdominal pain again. Repeated angiography demonstrated recanalization of the splenic artery and splenic artery aneurysm. This time, the recanalized aneurysm was embolized using metallic coils with the isolation method. Physicians should keep in mind thatmore » recanalization can occur after transcatheter arterial embolization using N-butyl cyanoacrylate, which has been used as a permanent embolic agent.« less

  13. Ureteric Embolization for Lower Urinary Tract Fistulae: Use of Two Amplatzer Vascular Plugs and N-Butyl Cyanoacrylate Employing the 'Sandwich' Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saad, Wael E. A., E-mail: ws6r@virginia.edu; Kalagher, S.; Turba, U. C.

    2013-08-01

    PurposeThis study describes and evaluated the effectiveness of occluding distal ureters in the clinical setting of urinary vaginal (vesicovaginal or enterovesicovaginal) fistulae utilizing a new technique which combines Amplatzer vascular plugs and N-butyl cyanoacrylate.MaterialsThis is a retrospective study (January 2007-December 2010) of patients with urinary-vaginal fistulae undergoing distal ureter embolization utilizing an Amplatzer- N-butyl cyanoacrylate-Amplatzer sandwich technique. An 8-12-mm type-I or type-II Amplatzer vascular plug was delivered using the sheath and deployed in the ureter distal to the pelvic brim. Instillation of 0.8-1.5 cc of N-butyl cyanoacrylate into ureter proximal to the Amplatzer plug was performed. This was followed bymore » another set of 8-12-mm type-I or type-II Amplatzer vascular plugs in a technique referred to as the 'sandwich technique.'ResultsFive ureters in three patients were occluded utilizing the above-described technique during the 4-year study period. Mean maximum size Amplatzer used per ureter was 10.8 mm (range, 8-12). One ureter required three Amplatzer plugs and the rest required two. Two patients (3 ureters) were clinically successful with complete resolution of symptoms in 36-48 h. The third patient (2 ureters) was partly successful and required a second Amplatzer- N-butyl cyanoacrylate sandwich technique embolization. The mean clinical follow-up was 11.3 months (range, 1.7-29.2).ConclusionsThe Amplatzer- N-butyl cyanoacrylate-Amplatzer sandwich technique for occluding the distal ureter is safe and effective with a quick (probably due to the N-butyl cyanoacrylate) and durable (probably due to the Amplatzer plugs) clinical response.« less

  14. A retrospective study of a new n-butyl-2-cyanoacrylate glue ablation catheter incorporated with application guiding light for the treatment of venous insufficiency: Twelve-month results.

    PubMed

    Yavuz, Turhan; Acar, Altay Nihat; Aydın, Huseyin; Ekingen, Evren

    2018-01-01

    Objective This study aims to present the early results of a retrospective study of the use of novel n-butyl-2-cyanoacrylate (VenaBlock)-based nontumescent endovenous ablation with a guiding light for the treatment of patients with varicose veins. Methods Patients with lower limb venous insufficiency were treated with n-butyl-2-cyanoacrylate (VenaBlock Venous Closure System) between April 2016 and July 2016. The study enrolled adults aged 21-70 years with symptomatic moderate to severe varicosities (C2-C4b) and great saphenous vein reflux lasting longer than 0.5 s with great saphenous vein diameter between 5.5 and 15 mm assessed in the standing position. No compression stockings were used after the procedure. Duplex ultrasound imaging and clinical follow-up were performed on the third day, first month, sixth month, and 12th month. Clinical, etiological, anatomical, pathophysiological classification; venous clinical severity score; and completed Aberdeen varicose vein questionnaire were recorded. Results Five hundred thirty-eight patients with great saphenous vein incompetency underwent n-butyl-2-cyanoacrylate ablation. The mean ablation length was 25.69 ± 4.8 cm, and the average amount of n-butyl-2-cyanoacrylate delivered was 0.87 ± 0.15 ml. The mean procedure time was 11.7 ± 4.9 min. Procedural success was 100%, and complete occlusion was observed after treatment and at the third-day follow-up. We observed ecchymosis in five patients (1.00%) at the entry site at the third-day follow-up. Phlebitis was encountered with six (1.20%) patients. No skin pigmentation, hematoma, paresthesia, deep vein thrombosis, or pulmonary embolism was observed. Kaplan-Meier analysis yielded an occlusion rate of 99.4% at the 12-month follow-up. All patients had significant improvement in venous clinical severity score and Aberdeen varicose vein questionnaire scores postoperatively ( p <0.0001). Venous clinical severity score scores decreased from 5.43 ± 0.87 to

  15. Collagen-Based Fillers as Alternatives to Cyanoacrylate Glue for the Sealing of Large Corneal Perforations.

    PubMed

    Samarawickrama, Chameen; Samanta, Ayan; Liszka, Aneta; Fagerholm, Per; Buznyk, Oleksiy; Griffith, May; Allan, Bruce

    2018-05-01

    To describe the use of collagen-based alternatives to cyanoacrylate glue for the sealing of acute corneal perforations. A collagen analog comprising a collagen-like peptide conjugated to polyethylene glycol (CLP-PEG) and its chemical crosslinker were tested for biocompatibility. These CLP-PEG hydrogels, which are designed to act as a framework for corneal tissue regeneration, were then tested as potential fillers in ex vivo human corneas with surgically created full-thickness perforations. Bursting pressures were measured in each of 3 methods (n = 10 for each condition) of applying a seal: 1) cyanoacrylate glue with a polyethylene patch applied ab externo (gold standard); 2) a 100-μm thick collagen hydrogel patch applied ab interno, and 3) the same collagen hydrogel patch applied ab interno supplemented with CLP-PEG hydrogel molded in situ to fill the remaining corneal stromal defect. Cyanoacrylate gluing achieved a mean bursting pressure of 325.9 mm Hg, significantly higher than the ab interno patch alone (46.3 mm Hg) and the ab interno patch with the CLP-PEG filler (86.6 mm Hg). All experimental perforations were sealed effectively using 100 μm hydrogel sheets as an ab interno patch, whereas conventional ab externo patching with cyanoacrylate glue failed to provide a seal in 30% (3/10) cases. An ab interno patch system using CLP-PEG hydrogels designed to promote corneal tissue regeneration may be a viable alternative to conventional cyanoacrylate glue patching for the treatment of corneal perforation. Further experimentation and material refinement is required in advance of clinical trials.

  16. Efficacy and safety of two different n-butyl-2-cyanoacrylates for the embolization of varicoceles: a prospective, randomized, blinded study.

    PubMed

    Vanlangenhove, Peter; De Keukeleire, Katrien; Everaert, Karel; Van Maele, Georges; Defreyne, Luc

    2012-06-01

    This was a prospective, randomized, blinded comparative study of the efficacy and safety of two different n-butyl-2-cyanoacrylates (NBCAs) for embolization of varicoceles. A total of 112 insufficient spermatic veins (left-sided, n=84; right-sided, n=28) that were diagnosed in 83 adult males were prospectively randomized for blinded embolization with NBCA (n=54; Histoacryl, Braun, Germany) or NBCA-MS (n=58; Glubran2, General Enterprise Marketing, Viareggio, Lucca, Italy). Handling, embolic efficacy, and safety of both NBCAs were compared according the fulfillment of a standardized embolization plan, the occlusive effect on the spermatic vein, and the sticking to the microcatheter. Statistical analysis was performed with the Mann-Whitney U test and the Fisher's exact test. Patients of both study arms were comparable for age and clinical indication. Spermatic vein characteristics were comparable for varicocele classification and embolization side. Both NBCAs were equally efficient in occluding the spermatic vein and blocking reflux (NBCA, n=54/54, 100% vs. NBCA-MS, n=54/57, 94.7%; P=0.244). The embolization plan could be accomplished in an equal number of veins for both groups (NBCA, n=45/54, 83.3% vs. NBCA-MS, n=41/58, 70.7%; P=0.124). Adhesiveness of the glue to the microcatheter was the same in both NBCA groups (NBCA, n=25/54, 46.3% vs. NBCA-MS, n=29/58, 50%; P=0.71). No glue-related complications were noted. NBCA and NBCA-MS are equally efficient and safe glues for embolization of varicoceles.

  17. Cyanoacrylate glue as an alternative mounting medium for resin-embedded semithin sections.

    PubMed

    Liu, Pei-Yun; Phillips, Gael E; Kempf, Margit; Cuttle, Leila; Kimble, Roy M; McMillan, James R

    2010-01-01

    Commercially available generic Superglue (cyanoacrylate glue) can be used as an alternative mounting medium for stained resin-embedded semithin sections. It is colourless and contains a volatile, quick-setting solvent that produces permanent mounts of semithin sections for immediate inspection under the light microscope. Here, we compare the use of cyanoacrylate glue for mounting semithin sections with classical dibutyl phthalate xylene (DPX) in terms of practical usefulness, effectiveness and the quality of the final microscopic image.

  18. Embolization of a High-Output Postnephrectomy Aortocaval Fistula with Gianturco Coils and Cyanoacrylate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cekirge, Saruhan; Oguzkurt, Levent; Saatci, Isil

    1996-11-15

    The authors describe the endovascular treatment of a high-output, large-caliber, postnephrectomy aortocaval fistula using a mixture of cyanoacrylate and lipiodol combined with Gianturco coil embolization. Thirty-nine coils were used to decrease the flow through the fistula so that a fast-polymerizing glue mixture could be injected into the fistula. During rapid polymerization, the N-butyl-2-cyanoacrylate (NBCA) mixture was trapped within the coils, providing an easily controllable glue cast in the fistula, thereby preventing inadvertent embolization into the lungs. This approach can be of considerable benefit for the endovascular treatment of central high-output fistulas.

  19. Endoscopic treatment of bleeding gastric varices with histoacryl (N-butyl-2-cyanoacrylate): a South European single center experience.

    PubMed

    Monsanto, Pedro; Almeida, Nuno; Rosa, Albano; Maçôas, Fernanda; Lérias, Clotilde; Portela, Francisco; Amaro, Pedro; Ferreira, Manuela; Gouveia, Hermano; Sofia, Carlos

    2013-07-01

    Endoscopic injection of N-butyl-2-cyanoacrylate is the current recommended treatment for gastric variceal bleeding. Despite the extensive worldwide use, there are still differences related to the technique, safety, and long term-results. We retrospectively evaluated the efficacy and safety of cyanoacrylate in patients with gastric variceal bleeding. Between January 1998 and January 2010, 97 patients with gastric variceal bleeding underwent endoscopic treatment with a mixture of N-butyl-2-cyanoacrylate and Lipiodol(TM). Ninety-one patients had cirrhosis and 6 had non-cirrhotic portal hypertension. Child-Pugh score at presentation for cirrhotic patients was A-12.1 %; B-53.8 %; C-34.1 % and median MELD score at admission was 13 (3-26). Successful hemostasis, rebleeding rate and complications were reviewed. Median time of follow up was 19 months (0.5-126). A median mixture volume of 1.5 mL (0.6 to 5 mL), in 1 to 8 injections, was used, with immediate hemostasis rate of 95.9 % and early rebleeding rate of 14.4 %. One or more complications occurred in 17.5 % and were associated with the use of Sengstaken-Blakemore tube before cyanoacrylate and very early rebleeding (p < 0.05). Hospital mortality rate during initial bleeding episode was 9.3 %. Very early rebleeding was a strong and independent predictor for in-hospital mortality (p < 0.001). Long-term mortality rate was 58.8 %, in most of the cases secondary to hepatic failure. N-butyl-2-cyanoacrylate is a rapid, easy and highly effective modality for immediate hemostasis of gastric variceal bleeding with an acceptable rebleeding rate. Patients with very early rebleeding are at higher risk of death.

  20. Use of Cyanoacrylate Glue Casting for Stabilization of Periocular Skin Grafts and Flaps.

    PubMed

    Jackson, Colette M; Nguyen, Michelle; Mancini, Ronald

    To examine a novel technique for periocular skin graft and flap stabilization using cyanoacrylate glue applied to the host bed around the perimeter of the graft or flap to create an immobile cast in the immediate postoperative period to promote successful graft take and stable anatomic position. Retrospective review was performed of a single surgeon's patients who underwent periocular skin graft or flap between August 1, 2011, and February 29, 2016, in which cyanoacrylate glue was applied postoperatively for graft stabilization. Data examined included indication for procedure, location and size of graft, postoperative complications, and length of follow up postoperatively. Of 164 cases reviewed, 9 cases were identified in which cyanoacrylate glue was used as the sole means of graft or flap stabilization. Indications for surgery included repair of cicatricial ectropion (3 cases) and repair of Mohs defect status after excision of basal or squamous cell carcinoma (6 cases). All cases involved reformation of the lower eyelid. Five cases employed full-thickness skin grafts and 4 cases employed adjacent tissue rearrangement. Size of defect repaired ranged from 8 mm to 35 mm when largest diameter was measured. Complications included mild residual ectropion or mild punctal ectropion in 2 patients who was asymptomatic and did not require further surgery. No cases were complicated by hematoma, infection, or graft necrosis. Cyanoacrylate glue can be used to successfully stabilize skin grafts and flaps in the immediate postoperative period.

  1. Transcatheter Embolization of a Coronary Fistula Originating from the Left Anterior Descending Artery by Using N-Butyl 2-Cyanoacrylate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karagoz, Tevfik; Celiker, Alpay; Cil, Barbaros

    In this report, we describe a successful percutaneous transcatheter n-butyl 2-cyanoacrylate embolization of a coronary fistula originating from the left anterior descending artery in an adolescent with unexpected recurrent attacks of myocardial ischemia.

  2. Percutaneous Direct Puncture Embolization with N-butyl-cyanoacrylate for High-flow Priapism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tokue, Hiroyuki, E-mail: tokue@s2.dion.ne.jp; Shibuya, Kei; Ueno, Hiroyuki

    There are many treatment options in high-flow priapism. Those mentioned most often are watchful waiting, Doppler-guided compression, endovascular highly selective embolization, and surgery. We present a case of high-flow priapism in a 57-year-old man treated by percutaneous direct puncture embolization of a post-traumatic left cavernosal arteriovenous fistula using N-butyl-cyanoacrylate. Erectile function was preserved during a 12-month follow-up. No patients with percutaneous direct puncture embolization for high-flow priapism have been reported previously. Percutaneous direct puncture embolization is a potentially useful and safe method for management of high-flow priapism.

  3. [The influence of biological compatibility of the cyanoacrylate glue on regeneration of the cartilaginous tissue].

    PubMed

    Semenov, F V; Skibitskaya, N F

    The objective of the present study was to evaluate the possibility of the application of the cyanoacrylate-based glue for the strengthening of the reconstructed elements of the middle ear and its influence on the regeneration of the cartilaginous tissue. We used the cartilaginous tissue from the auricles of the male California rabbits as a model. The cartilage was destroyed in a standard press. Half of the cartilage thus fragmented was implanted into the left auricle. The remaining part was mixed up with the cyanoacrylate glue and implanted into the right auricle of the same animal. The implanted material was used for the morphological study on day 10, within 1 and 2 months after the beginning of the experiment. The results of the study confirm the absence of the toxic action of the biologically compatible cyanoacrylate-based glue on the regeneration of the cartilaginous and connective tissues which suggests the possibility of its application for the surgical treatment of the diseases of the middle ear.

  4. Successful Pregnancy with a Full-Term Vaginal Delivery One Year After n-Butyl Cyanoacrylate Embolization of a Uterine Arteriovenous Malformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCormick, Colleen C.; Kim, Hyun S.

    Uterine arteriovenous malformation (AVM) causes significant morbidity with vaginal bleeding. Traditional therapy is a hysterectomy with no potential for future pregnancy. We present a case of successful superselective embolization of uterine AVM using n-butyl cyanoacrylate with subsequent normal term pregnancy and uncomplicated vaginal delivery in 1 year.

  5. Mycotic Celiac Artery Aneurysm Following Infective Endocarditis: Successful Treatment Using N-butyl Cyanoacrylate with Embolization Coils

    PubMed Central

    Ueda, Toshihiko; Koizumi, Jun; Cho, Yoshinori; Shimura, Shinichiro; Furuya, Hidekazu; Myojin, Kazunori; Okada, Kimiaki; Tanaka, Chiharu

    2012-01-01

    Mycotic celiac artery aneurysm following infective endocarditis is extremely rare and, to our knowledge, only four cases have been reported in the literature to date. We describe the case of a 60 year-old man who developed a mycotic aneurysm of the celiac artery, which was detected by computed tomography (CT) following an episode of infective endocarditis. He successfully underwent endovascular isolation and packing of the aneurysm using N-butyl cyanoacrylate (NBCA) with embolization coils. PMID:23555513

  6. Transcatheter Arterial Embolization of Intramuscular Active Hemorrhage with N-Butyl Cyanoacrylate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoo, Dong Hyun; Jae, Hwan Jun, E-mail: jhj@radiol.snu.ac.kr; Kim, Hyo-Cheol

    Purpose: This study was designed to evaluate the clinical efficacy and safety of transcatheter arterial embolization (TAE) with n-butyl cyanoacrylate (NBCA) for intramuscular active hemorrhage of varied etiologies and anatomic sites. Methods: Eighteen patients who demonstrated hematoma with pseudoaneurysm and/or active extravasation of contrast media underwent TAE with NBCA. Etiologies of hematoma included trauma, postoperative complication, and coagulopathy (due to underlying disease or anticoagulation therapy). Sites of embolization included chest wall, abdomen wall, retroperitoneum, and extremity. TAE was performed by using 1:3 to 1:5 mixtures of NBCA and iodized oil, either solely (n = 15) or in combination with microcoilmore » (n = 3). The technical and clinical success rate, procedure-related complications, and clinical outcomes were evaluated. Results: The technical and clinical success rates were 100% and 83% (15/18), respectively. Two patients expired while admitted due to other comorbidities. One patient expired due to recurrent bleeding at another site. There were no serious complications relating to the embolization procedure. Conclusions: TAE with NBCA is effective and safe treatment modality for intramuscular active hemorrhage.« less

  7. Cirsoid aneurysm of the right pre-auricular region: an unusual cause of tinnitus managed by endovascular glue embolisation.

    PubMed

    Kumar, A; Ahuja, C K; Khandelwal, N; Bakshi, J B

    2012-09-01

    We report an interesting case of a right temporal pre-auricular arteriovenous fistula (cirsoid aneurysm) causing intractable tinnitus successfully managed by transarterial n-butyl cyanoacrylate glue embolisation. A 52-year-old female presented with a one-year history of tinnitus and pulsatile swelling in the right pre-auricular region. A colour Doppler ultrasound test and magnetic resonance angiography revealed a high-flow scalp arteriovenous fistula with a feeder vessel from the distal superficial temporal artery, which drained into the corresponding, dilated, tortuous vein. The patient underwent diagnostic digital subtraction angiography. This was followed by transarterial embolisation of the fistula using a 50 per cent mixture of n-butyl cyanoacrylate glue and Lipiodol®, with manual distal venous occlusion. A successful outcome was achieved with instant relief of symptoms. Cirsoid aneurysms of the facial region, an uncommon cause of tinnitus, can be effectively managed by endovascular embolisation. This treatment obviates the need for surgery, which is associated with an increased risk of complications such as scarring, deformity and bleeding.

  8. Management of nontraumatic corneal perforation with tectonic drape patch and cyanoacrylate glue.

    PubMed

    Khalifa, Yousuf M; Bailony, M Rami; Bloomer, Michele M; Killingsworth, Daniel; Jeng, Bennie H

    2010-10-01

    To report a case of nontraumatic corneal perforation managed with a tectonic drape patch. Interventional case report. A 60-year-old patient with a corneal scar in his left eye likely secondary to herpes simplex virus interstitial keratitis underwent laser peripheral iridotomy for narrow angles. He developed progressive thinning of the cornea overlying the scar that led to a descemetocele and then ultimately a 1.2- × 1.7-mm perforation. Intraoperatively, several attempts were made to seal the perforation with cyanoacrylate glue, but the wound continued to leak. Sterile plastic drape that was on the surgical field was fashioned into a 2-mm-diameter patch, and the peripheral edge of the tectonic drape patch was glued over the perforation, successfully sealing the cornea. One week later, the drape patch was intact without leak, and a penetrating keratoplasty was carried out without complication. Tectonic drape patch technique for nontraumatic corneal perforations in which there is tissue loss is a viable temporizing option when cyanoacrylate glue alone fails and when there is no corneal tissue or amniotic membrane available to close the wound.

  9. Non-variceal upper gastrointestinal bleeding: Rescue treatment with a modified cyanoacrylate.

    PubMed

    Grassia, Roberto; Capone, Pietro; Iiritano, Elena; Vjero, Katerina; Cereatti, Fabrizio; Martinotti, Mario; Rozzi, Gabriele; Buffoli, Federico

    2016-12-28

    To evaluate the safety and efficacy of a modified cyanoacrylate [N-butyl-2-cyanoacrylate associated with methacryloxysulfolane (NBCA + MS)] to treat non-variceal upper gastrointestinal bleeding (NV-UGIB). In our retrospective study we took into account 579 out of 1177 patients receiving endoscopic treatment for NV-UGIB admitted to our institution from 2008 to 2015; the remaining 598 patients were treated with other treatments. Initial hemostasis was not achieved in 45 of 579 patients; early rebleeding occurred in 12 of 579 patients. Thirty-three patients were treated with modified cyanoacrylate: 27 patients had duodenal, gastric or anastomotic ulcers, 3 had post-mucosectomy bleeding, 2 had Dieulafoy's lesions, and 1 had duodenal diverticular bleeding. Of the 45 patients treated endoscopically without initial hemostasis or with early rebleeding, 33 (76.7%) were treated with modified cyanoacrylate glue, 16 (37.2%) underwent surgery, and 3 (7.0%) were treated with selective transarterial embolization. The mean age of patients treated with NBCA + MS (23 males and 10 females) was 74.5 years. Modified cyanoacrylate was used in 24 patients during the first endoscopy and in 9 patients experiencing rebleeding. Overall, hemostasis was achieved in 26 of 33 patients (78.8%): 19 out of 24 (79.2%) during the first endoscopy and in 7 out of 9 (77.8%) among early rebleeders. Two patients (22.2%) not responding to cyanoacrylate treatment were treated with surgery or transarterial embolization. One patient had early rebleeding after treatment with cyanoacrylate. No late rebleeding during the follow-up or complications related to the glue injection were recorded. Modified cyanoacrylate solved definitively NV-UGIB after failure of conventional treatment. Some reported life-threatening adverse events with other formulations, advise to use it as last option.

  10. Endolymphatic Ethiodized Oil Intranodal Lymphangiography and Cyanoacrylate Glue Embolization for the Treatment of Postoperative Lymphatic Leak After Robot-Assisted Laparoscopic Pelvic Resection.

    PubMed

    Hill, Hannah; Srinivasa, Ravi N; Gemmete, Joseph J; Hage, Anthony; Bundy, Jacob; Chick, Jeffrey Forris Beecham

    2018-01-01

    Purpose: To report the approach, technical success, clinical outcomes, complications, and follow-up of ethiodized oil intranodal lymphangiography with cyanoacrylate glue embolization for the treatment of lymphatic leak after robot-assisted laparoscopic pelvic resection. Materials and Methods: Four men with mean age 68.7 ± 14.3 years were treated with ethiodized oil intranodal lymphangiography with cyanoacrylate embolization for postoperative lymphatic leak. Patients underwent either (1) cystoprostatectomy with ileal conduit and bilateral extensive pelvic lymph node dissection for muscle-invasive urothelial carcinoma and presented with postoperative lymphatic ascites ( n  = 2) or (2) prostatectomy with bilateral standard pelvic lymph node dissection for prostate carcinoma and presented with postoperative pelvic lymphoceles ( n  = 2). Intranodal lymphangiography and embolization procedural details, technical success, clinical outcomes, and follow-up were recorded. Results: In four patients, a total of six ethiodized oil intranodal lymphangiograms were performed, two procedures being repeated interventions. Inguinal lymph node catheterization and ethiodized oil lymphangiography was technically effective in all procedures. A mean of 5.2 ± 2.0 mL of ethiodized oil was used for lymphatic opacification. Cyanoacrylate was diluted to 24.2% with ethiodized oil and 0.44 mL of cyanoacrylate was instilled during first time interventions. On repeat procedures, cyanoacrylate was diluted to 51.7%, and 0.52 mL was instilled. The primary clinical success rate was 50% ( n  = 2/4). Clinical success was achieved in all patients after two interventions ( n  = 4; 100%). No complications were reported at mean follow-up of 134.7 ± 79.2 days (range: 59-248 days). Conclusion: Ethiodized oil intranodal lymphangiography with direct cyanoacrylate glue embolization is a minimally invasive treatment option for lymphatic leak after pelvic resection.

  11. Transcatheter Embolotherapy with N-Butyl Cyanoacrylate for Ectopic Varices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Jin Woo; Kim, Hyo-Cheol, E-mail: angiointervention@gmail.com; Jae, Hwan Jun, E-mail: jaemdphd@gmail.com

    PurposeTo address technical feasibility and clinical outcome of transcatheter embolotherapy with N-butyl cyanoacrylate (NBCA) for bleeding ectopic varices.MethodsThe institutional review board approved this retrospective study and waived informed consent. From January 2004 to June 2013, a total of 12 consecutive patients received transcatheter embolotherapy using NBCA for bleeding ectopic varices in our institute. Clinical and radiologic features of the endovascular procedures were comprehensively reviewed.ResultsPreprocedural computed tomography images revealed ectopic varices in the jejunum (n = 7), stoma (n = 2), rectum (n = 2), and duodenum (n = 1). The 12 procedures consisted of solitary embolotherapy (n = 8) and embolotherapy with portal decompression (main portal vein stenting in 3,more » transjugular intrahepatic portosystemic shunt in 1). With regard to vascular access, percutaneous transhepatic access (n = 7), transsplenic access (n = 4), and transjugular intrahepatic portosystemic shunt tract (n = 1) were used. There was no failure in either the embolotherapy or the vascular accesses (technical success rate, 100 %). Two patients died within 1 month from the procedure from preexisting fatal medical conditions. Only one patient, with a large varix that had been partially embolized by using coils and NBCA, underwent rebleeding 5.5 months after the procedure. The patient was retreated with NBCA and did not undergo any bleeding afterward for a follow-up period of 2.5 months. The remaining nine patients did not experience rebleeding during the follow-up periods (range 1.5–33.2 months).ConclusionTranscatheter embolotherapy using NBCA can be a useful option for bleeding ectopic varices.« less

  12. Percutaneous trans-hepatic gelfoam-cyanoacrylate glue embolization for ruptured post-traumatic hepatic artery pseudo-aneurysm in a limited-resource scenario.

    PubMed

    Kumar, Manoj; Goel, Prabudh; Rawat, J D; Kumari, Shweta; Shankhwar, S N; Kureel, S N

    2013-05-01

    We present our experience with an indigenously designed percutaneous trans-hepatic ultrasound-guided Gelfoam sponge cum cyanoacrylate glue-based embolization technique for the treatment of a ruptured post-traumatic aneurysm of a branch of the right hepatic artery (RHA) as a 'life-saving emergent' procedure in a patient unfit for surgery or endovascular intervention and in a 'limited-resource' scenario (non-availability of Digital Subtraction Angiography Suite). An 8-year-old boy sustained crush-injury to the right lobe of the liver in a road-traffic accident and presented in shock. After resuscitation, a laparotomy and repair of the right lobe of liver were undertaken. Bleeding restarted 1 week after the surgery; the patient bled from drain site and went into shock. Exploration was not advisable in view of poor general condition, and sepsis, deranged coagulation and parental reluctance in view of guarded prognosis. Multi-detector Computed Tomography Angiography was performed after resuscitation which revealed active bleed from a ruptured pseudo-aneurysm of a branch of RHA. The bleeding artery was identified with duplex sonography and was embolized by the percutaneous trans-hepatic route proximal to the site of pseudo-aneurysm and rupture by a two-step process. Initially, a thin paste/'slurry' made of powdered gelfoam dissolved in sterile saline was injected into the bleeding vessel. Subsequently, the area was sealed by injecting 1.0 ml of N-butyl-2-cyanoacrylate glue. Hemostasis was confirmed by Color and Power Doppler Ultrasonography both post-procedure and after 48 h. With supportive management, the patient showed a rapid recovery and was discharged after 2 weeks. He continues to be well at 3-month follow-up. The technique was effective in controlling hemostasis and life-saving in our set-up.

  13. [The advantages in using cyanoacrylate glue over skin staples as a method of skin graft fixation in the pediatric burns population].

    PubMed

    Curings, P; Vincent, P-L; Viard, R; Gir, P; Comparin, J-P; Voulliaume, D

    2017-11-23

    Local postoperative care and burn wound management can present with a certain degree of difficulty in the pediatric population. While the use of skin staples as a method of skin graft fixation is a well-known, rapid and simple method, their removal can be painful and may necessitate some sedation or even general anesthesia. We studied in this article the advantages and economic value of using the cyanoacrylate glue as a fixation method for skin grafts. A comparative study was carried out from 2012 to 2016. Hundred and eighteen infants with burns up to 5% of total body surface area were included in the study. Seventy-two infants had split thickness skin grafts fixed with skin staples. Forty-six infants had split thickness skin grafts fixed with cyanoacrylate glue. We compared the quality of graft, the sedation used during the first postoperative dressing, the length of hospital stay, the amount of glue used and the presence of complications. There is a difference between the two groups studied in terms of age and total burn surface area. The rate of graft take was 100% in both groups. The first postoperative dressing was carried out without the use of powerful analgesia in the cyanoacrylate group, while it was necessary to use general anesthesia in 64% of the skin staples group. The average length of stay in hospital after skin grafting was 4.9 days for the cyanoacrylate glue versus 6.5 days in the skin staples group. No complications were noted in the 2 groups. The use of cyanoacrylate glue allows rapid fixation of skin grafts and avoid general anesthesia for postoperative cares. Subsequently the length of hospital stay is reduced within 25%. The medico-economic value of glue protocol is highly significant compared to skin staples, while having similar good results and without significant problems. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. Harvesting keratolimbal allografts from corneoscleral buttons: a novel application of cyanoacrylate adhesive.

    PubMed

    Lim, L T; Bhatt, P R; Ramaesh, K

    2008-11-01

    To describe an alternative and novel technique using cyanoacrylate glue to achieve successful limbal tissue dissection, from an organ culture media stored corneoscleral button, without an artificial anterior chamber. A donor corneoscleral button (leftover from penetrating keratoplasty) was divided into two equal semicircular halves. A thick layer of tissue adhesive (N-butyl-2-cyanoacrylate) was spread on a sterile rubber block (the under surface of the donor punch). One half of the donor corneoscleral rim was placed epithelial side up on the adhesive and allowed to attach firmly to the block. This composite provided stability to the donor rim allowing lamellar dissection of the limbal tissue to be performed without damaging the limbal epithelium. Regular, partial-thickness limbal tissue was obtained. There was no histological evidence of glue or cellular toxicity of the harvested limbal stem cells. This harvested tissue had been grafted successfully in patients with limbal stem cell deficiency also undergoing keratoplasty. Tissue adhesive can be a simple, effective and useful tool in the dissection and harvesting of corneal limbal stem cell allografts from corneoscleral buttons stored in organ culture media.

  15. Healing at the Interface Between Autologous Block Bone Grafts and Recipient Sites Using n-Butyl-2-Cyanoacrylate Adhesive as Fixation: Histomorphometric Study in Rabbits.

    PubMed

    De Santis, Enzo; Silva, Erick Ricardo; Martins, Evandro Neto Carneiro; Favero, Riccardo; Botticelli, Daniele; Xavier, Samuel Porfirio

    2017-12-01

    The aim of the present split-mouth (split-plot) study was to describe the sequential healing in the interface between autologous bone grafts and recipient parent bone, fixed using an n-butyl-2-cyanoacrylate adhesive with or without an additional titanium fixation screw. Bone grafts were collected from the calvaria and fixed to the lateral aspect of the mandible in 24 rabbits. The cortical layers of the recipient sites were perforated, and the grafts were randomly fixed using an n-butyl-2-cyanocrylate adhesive, either alone or in conjunction with a 1.5 mm × 6.0 mm titanium fixation screw. The animals were sacrificed after 3, 7, 20, and 40 days, and histomorphometric evaluations of the interface between graft and parent bone were performed. Only 2 of 6 grafts in each group were partially incorporated to the parent bone after 40 days of healing. The remaining grafts were separated from the parent bone by adhesive and connective tissue. It was concluded that the use of n-butyl-2-cyanoacrylate as fixation of an autologous bone graft to the lateral aspect of the mandible was able to maintain the fixation over time but did not incorporate the graft to the recipient sites. Use of fixation screws did not improve the healing.

  16. Successful Embolization of Bleeding Ileal Varices with N-butyl Cyanoacrylate via a Recanalized Paraumbilical Vein.

    PubMed

    Onishi, Yasuyuki; Kimura, Hiroyuki; Kanagaki, Mitsunori; Oka, Shojiro; Fukumoto, Genki; Otani, Tomoaki; Matsubara, Naoko; Kawabata, Kazuna; Namikawa, Mio; Matsumura, Takeshi; Kimura, Toshiyuki

    2018-04-23

    A 48-year-old woman with alcoholic liver cirrhosis was admitted to our hospital because of hematochezia and severe anemia. She had been hospitalized many times over the past year for hematochezia of unknown etiology. Contrast-enhanced CT demonstrated ileal varices, which were fed by several ileal veins. These feeding veins were selectively embolized with N-butyl cyanoacrylate (NBCA) via a recanalized paraumbilical vein. The paraumbilical vein instead of the portal vein was punctured to decrease the risk of bleeding complications because she had coagulopathy and ascites. We consider antegrade embolization of ileal varices with NBCA to be a feasible and effective treatment. Access via a paraumbilical vein is an alternative to the transhepatic approach.Level of Evidence Level V, case report.

  17. Use of n-butyl cyanoacrylate to reduce left to right shunting of an abdominal arteriovenous malformation in a dog.

    PubMed

    Eason, B D; Hogan, D F; Lim, C; Hogan, M J

    2017-08-01

    A 9-month old castrated male Labradoodle presented to the cardiology service at Purdue University for evaluation of a low-grade murmur. Physical examination, thoracic radiography, and echocardiography were strongly supportive of an extracardiac left-to-right shunt. Subsequent evaluation with nuclear scintigraphy and computed tomography angiography revealed a large, complex arteriovenous malformation within the cranial abdomen. Staged interventional attenuation of the shunt was performed using n-butyl cyanoacrylate that resulted in a reduction in echocardiographic and nuclear scintigraphy derived shunt estimation. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Safe and successful endoscopic initial treatment and long-term eradication of gastric varices by endoscopic ultrasound-guided Histoacryl (N-butyl-2-cyanoacrylate) injection.

    PubMed

    Gubler, Christoph; Bauerfeind, Peter

    2014-09-01

    Optimal endoscopic treatment of gastric varices is still not standardized nowadays. Actively bleeding varices may prohibit a successful endoscopic injection therapy of Histoacryl® (N-butyl-2-cyanoacrylate). Since 2006, we have treated gastric varices by standardized endoscopic ultrasound (EUS) guided Histoacryl injection therapy without severe adverse events. We present a large single-center cohort over 7 years with a standardized EUS-guided sclerotherapy of all patients with gastric varices. Application was controlled by fluoroscopy to immediately detect any glue embolization. Only perforating veins located within the gastric wall were treated. In the follow up, we repeated this treatment until varices were eradicated. Utmost patients (36 of 40) were treated during or within 24 h of active bleeding. About 32.5% of patients were treated while visible bleeding. Histoacryl injection was always technically successful and only two patients suffered a minor complication. Acute bleeding was stopped in all patients. About 15% (6 of 40) of patients needed an alternative rescue treatment in the longer course. Three patients got a transjugular portosystemic shunt and another three underwent an orthotopic liver transplantation. Mean long-term survival of 60 months was excellent. Active bleeding of gastric varices can be treated successfully without the necessity of gastric rinsing with EUS-guided injection of Histoacryl.

  19. Delayed onset pulmonary glue emboli in a ventilated patient: a rare complication following endoscopic cyanoacrylate injection for gastric variceal haemorrhage

    PubMed Central

    Chew, Joyce Ruo Yi; Balan, Anu; Griffiths, William; Herre, Jurgen

    2014-01-01

    Cyanoacrylate injection is a recognised endoscopic treatment option for variceal haemorrhage. We describe a 34-year old man with hepatitis B cirrhosis who presented to the hospital with upper gastrointestinal haemorrhage from gastric and oesophageal varices. Haemostasis was achieved via cyanoacrylate injection sclerotherapy and banding. Ten days later, the patient developed acute hypoxia and fever. His chest radiograph showed wide-spread pulmonary shadowing. A non-contrast CT scan confirmed multiple emboli of injected glue material from the varix with parenchymal changes either suggesting acute lung injury or pulmonary oedema. He gradually recovered with supportive treatment and was discharged home. On follow-up, he remained asymptomatic from a chest perspective. This case report discusses the rare complication of pulmonary embolisation of cyanoacrylate glue from variceal injection sites and the diagnostic dilemmas involved. Emphasis is placed on the importance of maintaining high index of clinical suspicion when assessing patients with possible procedure related complications. PMID:25320260

  20. Successful treatment of acquired uterine arterial venous malformation using N-butyl-2-cyanoacrylate under balloon occlusion

    PubMed Central

    Ogasawara, Go; Ishida, Kenichiro; Fujii, Kaoru; Yamane, Takuro; Nishimaki, Hiroshi; Matsunaga, Keiji; Inoue, Yusuke

    2014-01-01

    We present two cases of acquired uterine arterial venous malformation (AVM) which was diagnosed because of massive genital bleeding successfully treated with transcatheter arterial embolization (TAE), using N-butyl-2-cyanoacrylate (NBCA) under balloon occlusion. Balloon occlusion at the uterine artery was performed in both patients for diffuse distribution of NBCA in multiple feeding branches, as well as to the pseudoaneurysm, and for the prevention of NBCA reflux. In one of our patients, balloon occlusion of the draining vein was simultaneously performed to prevent NBCA migration through accompanying high-flow arteriovenous fistula (AVF). Doppler ultrasound at 6 months of both patients documented persistent complete occlusion of AVM. Complete and safe obliteration of acquired uterine AVM was accomplished using NBCA as embolic agent, under balloon occlusion at the communicating vessels of acquired uterine AVM. PMID:25346850

  1. Structural Analysis and Application of n-Alkyl Cyanoacrylate Surgical Adhesives to the Fixation of Meshes for Hernia Repair.

    PubMed

    Fernández-Gutiérrez, Mar; Rodriguez-Mancheño, Marta; Pérez-Köhler, Bárbara; Pascual, Gemma; Bellón, Juan Manuel; Román, Julio San

    2016-12-01

    The article deals with a comparative analysis of the parameters of the polymerization in physiological conditions of three commercially available alkyl cyanoacrylates, n-butyl cyanoacrylate (GLUBRAN 2), n-hexyl cyanoacrylate (IFABOND), and n-octyl cyanoacrylate (EVOBOND), the cell behavior of the corresponding polymers and the application of these adhesives in the fixation of surgical polypropylene meshes for hernia repair in an animal model of rabbits. The results obtained demonstrate that the curing process depends on the nature of the alkyl residue of the ester group of cyanoacrylate molecules, being the heat of polymerization lower for the octyl derivative in comparison with the hexyl and butyl, and reaching a maximum temperature of 35 °C after a time of mixing with physiological fluids of 60-70 s. The cell behavior demonstrates that the three systems do not present toxicity for fibroblasts and low adhesion of cells, which is a positive result for application as tissue adhesives, especially for the fixation of abdominal polypropylene meshes for hernia repair. The animal experimentation indicates the excellent tolerance of the meshes fixed with the cyanoacrylic adhesives, during at least a period of 90 d, and guarantees a good adhesion for the application of hernia repair meshes. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Preliminary Experience of Endovascular Embolization Using N-Butyl Cyanoacrylate for Hemoptysis due to Infectious Pulmonary Artery Pseudoaneurysms via Systemic Arterial Approach.

    PubMed

    Torikai, Hideyuki; Hasegawa, Ichiro; Jinzaki, Masahiro; Narimatsu, Yoshiaki

    2017-10-01

    We report 5 patients with hemoptysis due to infectious pulmonary artery pseudoaneurysm (PAP) treated with endovascular embolization using N-butyl cyanoacrylate (NBCA) injected via bronchial and nonbronchial systemic arterial approaches. Infectious diseases included inactive tuberculosis (n = 3), nontuberculous mycobacteriosis (n = 1), and chronic infection of unknown origin (n = 1). Seven PAPs were detected on selective systemic angiography, and injection of NBCA was performed. Disappearance of all PAPs was confirmed on systemic arteriography after the intervention. In all patients, hemoptysis was stopped without major complications, and it did not recur during the follow-up period (mean, 351 d; range, 285-427 d). Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  3. Recanalization after successful occlusion by transcatheter arterial embolization with N-butyl cyanoacrylate for traumatic splenic artery injury.

    PubMed

    Ishikawa, Masaki; Kakizawa, Hideaki; Yamasaki, Wataru; Date, Syuji; Hieda, Masashi; Kajiwara, Kenji; Awai, Kazuo

    2011-12-01

    A 70-year-old male with advanced pancreatic cancer went into shock after sustaining a traumatic abdominal injury. Computed tomography (CT) showed a hematoma with extravasation around the pancreas and hemorrhagic ascites. After direct catheterization failed due to angiospasm, the ruptured splenic artery was successfully occluded by transcatheter arterial embolization (TAE) using an N-butyl cyanoacrylate (NBCA)-lipiodol mixture and the patient recovered from shock without complications. A follow-up CT obtained 20 days later showed a recurrent splenic artery pseudoaneurysm without extravasation. A repeat angiogram demonstrated recanalization of the splenic artery and pseudoaneurysm via antegrade. We embolized the recanalized pseudoaneurysm using metallic coils for isolation. Our experience indicates that adequate concentration and volume of the NBCA-lipiodol mixture should be considered depending on the vascular spasm in a patient with hypovolemic shock.

  4. A New Flow Control Technique Using Diluted Epinephrine in the N-butyl-2-cyanoacrylate Embolization of Visceral Artery Pseudoaneurysms Secondary to Chronic Pancreatitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morishita, Hiroyuki, E-mail: hmorif@koto.kpu-m.ac.jp; Yamagami, Takuji; Takeuchi, Yoshito

    2012-08-15

    Although n-butyl-2-cyanoacrylate (NBCA) has been used as an effective liquid embolization material, its indication for pseudoaneurysms has seemingly been limited because of the technical difficulties of using NBCA, such as reflux to the parent artery and causing significant infarction. Thus, considerable skill in using NBCA or a device to control blood flow during its polymerization is required to achieve embolization without severe complications. We report our new technique for controlling blood flow using diluted epinephrine in transcatheter arterial NBCA embolization of five pseudoaneurysms in four cases secondary to hemosuccus pancreaticus.

  5. Genuine splenic artery aneurysm rupture treated by N‐butyl cyanoacrylate and metallic coils under resuscitative endovascular balloon occlusion of the aorta

    PubMed Central

    Hagiwara, Shuichi; Miyazaki, Masaya; Kaneko, Minoru; Murata, Masato; Nakajima, Jun; Ohyama, Yoshio; Tamura, Jun'ichi; Tsushima, Yoshito; Oshima, Kiyohiro

    2016-01-01

    Case A 66 year‐old woman who presented with sudden lower abdominal pain was transferred to our emergency room. Vital signs were stable on arrival at the hospital, but immediately became unstable. Systolic/diastolic blood pressure and heart rate were 66/33 mmHg and 70 b.p.m., respectively. Computed tomography scanning showed splenic artery aneurysm rupture and extravasation. The patient was treated non‐operatively and definitively by endovascular therapy comprising resuscitative endovascular occlusion of the aorta for hemodynamic control, N‐butyl cyanoacrylate, and metallic coils as an embolization material. Outcome On admission day 3, she was enrolled in another department and admission day 54, she was discharged. Conclusion Although resuscitative endovascular occlusion of the aorta and N‐butyl cyanoacrylate is known to be effective, the use of resuscitative endovascular occlusion of the aorta with transcatheter arterial embolization and N‐butyl cyanoacrylate for non‐traumatic bleeding has not previously been reported. By combining and adapting these devices, their applications in endovascular management may be increased. PMID:29123801

  6. Biomechanical and histologic evaluation of two application forms of surgical glue for mesh fixation to the abdominal wall.

    PubMed

    Ortillés, Á; Pascual, G; Peña, E; Rodríguez, M; Pérez-Köhler, B; Mesa-Ciller, C; Calvo, B; Bellón, J M

    2017-11-01

    The use of an adhesive for mesh fixation in hernia repair reduces chronic pain and minimizes tissue damage in the patient. This study was designed to assess the adhesive properties of a medium-chain (n-butyl) cyanoacrylate glue applied as drops or as a spray in a biomechanical and histologic study. Both forms of glue application were compared to the use of simple-loose or continuous-running polypropylene sutures for mesh fixation. Eighteen adult New Zealand White rabbits were used. For mechanical tests in an ex vivo and in vivo study, patches of polypropylene mesh were fixed to an excised fragment of healthy abdominal tissue or used to repair a partial abdominal wall defect in the rabbit respectively. Depending on the fixation method used, four groups of 12 implants each or 10 implants each respectively for the ex vivo and in vivo studies were established: Glue-Drops, Glue-Spray, Suture-Simple and Suture-Continuous. Biomechanical resistance in the ex vivo implants was tested five minutes after mesh fixation. In vivo implants for biomechanical and histologic assessment were collected at 14 days postimplant. In the ex vivo study, the continuous suture implants showed the highest failure sample tension, while the implants fixed with glue showed lower failure sample tension values. However, the simple and continuous suture implants returned the highest stretch values. In the in vivo implants, failure sample tension values were similar among groups while the implants fixed with a continuous running suture had the higher stretch values, and the glue-fixed implants the lower stretch values. All meshes showed good tissue integration within the host tissue regardless of the fixation method used. Our histologic study revealed the generation of a denser, more mature repair tissue when the cyanoacrylate glue was applied as a spray rather than as drops. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Double Coaxial Microcatheter Technique for Glue Embolization of Renal Arteriovenous Malformations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uchikawa, Yoko, E-mail: jauchikawa@gmail.com; Mori, Kensaku, E-mail: moriken@md.tsukuba.ac.jp; Shiigai, Masanari, E-mail: m-41gai@yahoo.co.jp

    PurposeTo demonstrate the technical benefit of the double coaxial microcatheter technique for embolization of renal arteriovenous malformations (AVMs) with n-butyl cyanoacrylate and iodized oil (glue).Materials and MethodsSix consecutive patients (1 man and 5 women; mean age 61 years; range 44–77 years) with renal AVMs were included. Five patients had hematuria, and one had a risk of heart failure due to a large intrarenal arteriovenous shunt. All patients underwent transarterial embolization using glue and the double coaxial microcatheter technique with outer 2.6F and inner 1.9F microcatheters. After glue injection, the inner microcatheter was retracted, while the outer microcatheter was retained. We assessed themore » complications and clinical outcomes of this technique.ResultsTechnical success was achieved in all patients. In 9 sessions, 34 feeding arteries were embolized with glue using the double coaxial microcatheter technique, 1 was embolized with glue using a single microcatheter, and 2 were embolized with coils. The double coaxial microcatheter technique was useful for selecting small tortuous feeding arteries, preventing glue reflux to the proximal arteries, and approaching multiple feeding arteries without complete retraction of the microcatheters. As a minor complication, glue migrated into the venous system in four patients without any sequelae. In all patients, favorable clinical outcomes, including hematuria cessation in five patients and improvement of the large intrarenal arteriovenous shunt in one patient, were obtained without deterioration of renal function.ConclusionGlue embolization with the double coaxial microcatheter technique was useful for treating renal AVMs with multiple tortuous feeding arteries.« less

  8. Single-stage excision of localized head and neck venous malformations using preoperative glue embolization.

    PubMed

    Tieu, David D; Ghodke, Basavaraj V; Vo, Nghia J; Perkins, Jonathan A

    2013-04-01

    Describe single-stage removal of head and neck venous malformations using percutaneous embolization with n-butyl cyanoacrylate (n-BCA) glue prior to surgical resection. Case series with chart review. Tertiary-care pediatric hospital. A total of 169 venous malformations were identified between 2000 and 2012, and 102 (60.1%) were in the head and neck. Thirty-five of 102 (34.3%) were observed, 56 of 102 (54.9%) had invasive therapy, and 11 of 102 (10.8%) underwent n-BCA embolization and surgery ("GES procedure"). The median age of the glue embolization and surgery cohort was 14 years (range, 6-19), and 7 of 11 (63.6%) were female. Treated venous malformations involved the oral cavity/tongue (4/11; 36.4%) and parotid/face (7/11; 63.6%). During facial lesion excision, intraoperative facial nerve monitoring was used. All surgical sites (11/11) were closed primarily. No patient in this cohort had any posttreatment nerve deficits, dysarthria, and dysphagia or lesion persistence. Localized venous malformations can be treated with preoperative percutaneous embolization with n-BCA glue followed by surgical excision. This technique, with selective motor nerve monitoring, appears safe and allows for complete venous malformation removal with limited nerve dissection, to allow maximal tissue and functional preservation.

  9. Malignant biliary obstruction complicated by ascites: Closure of the transhepatic tract with cyanoacrylate glue after placement of an endoprosthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cekirge, Saruhan; Akhan, Okan; Ozmen, Mustafa

    1997-05-15

    A new technique using cyanoacrylate glue is suggested for closing the transparenchymal tract following metallic endoprosthesis placement in a patient with malignant biliary obstruction complicated by ascites. With this technique, complications related to bile reflux through the transparenchymal tract would be avoided after transhepatic endoprosthesis placement in patients who have ascites. This technique would also be useful for avoiding bleeding following transhepatic portal venous puncture.

  10. Airflow-directed in situ electrospinning of a medical glue of cyanoacrylate for rapid hemostasis in liver resection

    NASA Astrophysics Data System (ADS)

    Jiang, Kai; Long, Yun-Ze; Chen, Zhao-Jun; Liu, Shu-Liang; Huang, Yuan-Yuan; Jiang, Xingyu; Huang, Zhi-Qiang

    2014-06-01

    Rapid hemostasis of solitary organs is still a big challenge in surgical procedures or after major trauma in both civilians and on the battlefield. Here, we report the first use of an airflow-directed in situ electrospinning method to precisely and homogeneously deposit a medical glue of n-octyl-2-cyanoacrylate (OCA) ultrathin fibers onto a wound surface to realize rapid hemostasis in dozens of seconds. In vivo and in vitro experiments on pig liver resection demonstrate that the self-assembled electrospun OCA membrane with high strength, good flexibility and integrity is very compact and no fluid seeping is observed even under a pressure of 147 mm Hg. A similar effect has been achieved in an in vivo experiment on pig lung resection. The results provide a very promising alternative for rapid hemostasis of solitary organs as well as other traumas, providing evidence that the postoperative drainage tube may not be always necessary for surgery in the near future.Rapid hemostasis of solitary organs is still a big challenge in surgical procedures or after major trauma in both civilians and on the battlefield. Here, we report the first use of an airflow-directed in situ electrospinning method to precisely and homogeneously deposit a medical glue of n-octyl-2-cyanoacrylate (OCA) ultrathin fibers onto a wound surface to realize rapid hemostasis in dozens of seconds. In vivo and in vitro experiments on pig liver resection demonstrate that the self-assembled electrospun OCA membrane with high strength, good flexibility and integrity is very compact and no fluid seeping is observed even under a pressure of 147 mm Hg. A similar effect has been achieved in an in vivo experiment on pig lung resection. The results provide a very promising alternative for rapid hemostasis of solitary organs as well as other traumas, providing evidence that the postoperative drainage tube may not be always necessary for surgery in the near future. Electronic supplementary information (ESI) available

  11. Transcatheter Arterial Embolization with N-Butyl-2-Cyanoacrylate in the Management of Spontaneous Hematomas.

    PubMed

    Ozyer, Umut

    2017-01-01

    Spontaneous hematoma refractory to conservative management is a potentially serious condition that requires prompt diagnosis and intervention. The purpose of this study was to evaluate the performance of computed tomography (CT) in the treatment planning and to report the effectiveness of transcatheter embolization with N-butyl-2-cyanoacrylate (NBCA). Forty-one interventions in 38 patients within a 12-year period were evaluated. CT and angiograms were reviewed for the location of the hematoma, the presence of extravasation, and the correlation of CT and angiography findings. Arterial extravasation was present on 34/39 CT scans. Angiograms confirmed the CT scans in 29 cases. Angiograms revealed extravasation in four cases which CT showed venous bleeding (n = 2) or no bleeding (n = 2). Five patients with arterial and 1 patient with venous extravasation on CT images had no extravasation on angiograms. Embolization was performed to all arteries with extravasation on angiograms. Empiric embolization of the corresponding artery on the CT was performed when there was no extravasation on angiograms. Embolization procedures were performed with 15 % NBCA diluted with iodized oil. Technical success was achieved in 40/41 (97.6 %) interventions. Clinical success was achieved in 35 patients with a single, in 1 patient with 2, and in 1 patient with 3 interventions. No complications related to embolization procedure occurred. None of the patients died due to a progression of the hematoma. NBCA is an effective and safe embolic agent to treat hematoma refractory to conservative management. Contrast-enhanced CT may provide faster and more effective intervention. Retrospective.

  12. Percutaneous protective coil occlusion of the proximal inferior mesenteric artery before N-butyl cyanoacrylate embolization of type II endoleaks after endovascular repair of abdominal aortic aneurysms.

    PubMed

    Chao, Christine P; Paz-Fumagalli, Ricardo; Walser, Eric M; McKinney, J Mark; Stockland, Andrew H; Falkensammer, Jürgen; Hakaim, Albert G; Oldenburg, W Andrew

    2006-11-01

    Bowel ischemia can complicate treatment of type II endoleak with liquid or semiliquid agents such as n-butyl cyanoacrylate (NBCA) if nontarget embolization of the inferior mesenteric artery (IMA) occurs. The current report describes four cases of type II endoleak in which the IMA was the main outflow vessel and was prophylactically occluded with embolization coils before NBCA injection into the endoleak nidus. The purpose was to prevent unintentional embolization of the NBCA into IMA branches. If feasible, protective IMA coil occlusion should be considered in type II endoleaks with IMA outflow in cases of NBCA embolization.

  13. Transcatheter Arterial Embolization with N-Butyl-2-Cyanoacrylate in the Management of Spontaneous Hematomas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ozyer, Umut, E-mail: umutozyer@gmail.com

    IntroductionSpontaneous hematoma refractory to conservative management is a potentially serious condition that requires prompt diagnosis and intervention. The purpose of this study was to evaluate the performance of computed tomography (CT) in the treatment planning and to report the effectiveness of transcatheter embolization with N-butyl-2-cyanoacrylate (NBCA).Materials and MethodsForty-one interventions in 38 patients within a 12-year period were evaluated. CT and angiograms were reviewed for the location of the hematoma, the presence of extravasation, and the correlation of CT and angiography findings.ResultsArterial extravasation was present on 34/39 CT scans. Angiograms confirmed the CT scans in 29 cases. Angiograms revealed extravasation inmore » four cases which CT showed venous bleeding (n = 2) or no bleeding (n = 2). Five patients with arterial and 1 patient with venous extravasation on CT images had no extravasation on angiograms. Embolization was performed to all arteries with extravasation on angiograms. Empiric embolization of the corresponding artery on the CT was performed when there was no extravasation on angiograms. Embolization procedures were performed with 15 % NBCA diluted with iodized oil. Technical success was achieved in 40/41 (97.6 %) interventions. Clinical success was achieved in 35 patients with a single, in 1 patient with 2, and in 1 patient with 3 interventions. No complications related to embolization procedure occurred. None of the patients died due to a progression of the hematoma.ConclusionNBCA is an effective and safe embolic agent to treat hematoma refractory to conservative management. Contrast-enhanced CT may provide faster and more effective intervention.Level of Evidence IIIRetrospective.« less

  14. Endovascular Embolization of Intracranial Infectious Aneurysms in Patients Undergoing Open Heart Surgery Using n-Butyl Cyanoacrylate.

    PubMed

    Cheng-Ching, Esteban; John, Seby; Bain, Mark; Toth, Gabor; Masaryk, Thomas; Hui, Ferdinand; Hussain, Muhammad Shazam

    2017-03-01

    Mycotic aneurysms are a serious complication of infective endocarditis with increased risk of intracranial hemorrhage. Patients undergoing open heart surgery for valve repair or replacement are exposed to anticoagulants, increasing the risk of aneurysm bleeding. These patients may require endovascular or surgical aneurysm treatment prior to heart surgery, but data on this approach are scarce. Retrospective review of consecutive patients with infectious endocarditis and mycotic aneurysms treated endovascularly with Trufill n-butyl cyanoacrylate (n-BCA) at the Cleveland Clinic between January 2013 and December 2015. Nine patients underwent endovascular treatment of mycotic aneurysms with n-BCA (mean age of 39 years). On imaging, 4 patients had intracerebral hemorrhage, 2 had multiple embolic infarcts, and the rest had no imaging findings. Twelve mycotic aneurysms were detected (3 patients with 2 aneurysms). Seven aneurysms were in the M4 middle cerebral artery segment, 4 in the posterior cerebral artery distribution, and 1 in the callosomarginal branch. n-BCA was diluted in ethiodized oil (1:1 to 1:2). Embolization was achieved in a single rapid injection with immediate microcatheter removal. Complete aneurysm exclusion was achieved in all cases without complications. All patients underwent open heart surgery and endovascular embolization within a short interval, 2 with both procedures on the same day. There were no new hemorrhages after aneurysm embolization. Endovascular embolization of infectious intracranial aneurysms with liquid embolics can be performed successfully in critically ill patients requiring immediate open heart surgery and anticoagulation. Early embolization prior to and within a short interval from open heart surgery is feasible.

  15. Krazy Glue® in the ear: A case report of child abuse.

    PubMed

    Sorichetti, Brendan D; Fandiño, Marcela; Kozak, Frederick K

    2018-06-01

    Krazy Glue ® or cyanoacrylate glue is an acrylic resin that polymerizes in less than a minute when in contact with moisture or water. We present a case of a one month old referred to our tertiary pediatric otolaryngology clinic from an outside emergency department with a history of application of cyanoacrylate glue in the external ear canals. This report presents the management of this case along with the medical and legal outcomes surrounding this case of child abuse. Copyright © 2018. Published by Elsevier B.V.

  16. Selective transarterial embolization with n-butyl-2-cyanoacrylate for the treatment of arterial hemorrhage after third molar extraction.

    PubMed

    Sagara, Yoshiko; Kiyosue, Hiro; Tanoue, Shuichi; Shimada, Ryuichi; Hongo, Norio; Kohno, Tatsuyuki; Kawano, Kenji; Mori, Hiromu

    2013-06-01

    Comprehensive reports concerning selective embolization for arterial bleeding from third molar removal have not been published. We analyzed cases of arterial bleeding from third molar extraction that required transarterial embolization, and we demonstrate representative cases. Five consecutive patients (three men and two women, aged 24 to 37 years) who underwent transarterial embolization at our institution were included in this study. Four of them showed postoperative bleeding after lower third molar removal, and one suffered bleeding after upper third molar extraction. The period of time from extraction to embolization varied from 5 h to 5 weeks. Angiography revealed pseudoaneurysms at the inferior alveolar artery in four cases and at the superior alveolar artery in one case. The pseudoaneurysms were selectively embolized using 25-33 % n-butyl-2-cyanoacrylate (NBCA)-lipiodol. All of the cases showed good results angiographically and clinically. Transit hypoesthesia at the region of the mental nerve was observed in one patient. Selective transarterial embolization is an effective technique for arterial bleeding from third molar removal when it is difficult to obtain hemostasis by dental procedures. Injection of NBCA can be useful when the alveolar artery is too small to embolize with coils.

  17. Transcatheter Arterial Embolization with n-Butyl Cyanoacrylate for the Treatment of Acquired Uterine Vascular Malformations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Picel, Andrew C., E-mail: apicel@ucsd.edu; Koo, Sonya J.; Roberts, Anne C.

    PurposeThe purpose of the study was to evaluate the technique and outcomes of transcatheter arterial embolization (TAE) with n-butyl cyanoacrylate (NBCA) for the treatment of acquired uterine arteriovenous malformations (AVMs).Materials and methodsA retrospective review identified five women treated for suspected acquired uterine AVMs with TAE at our institution. Four women (80 %) presented with heavy or intermittent vaginal bleeding after obstetric manipulation. One woman (20 %) was treated for an incidental AVM discovered on ultrasound after an uncomplicated cesarean section. Three women underwent one embolization procedure and two women required two procedures. Embolization material included NBCA in six procedures (80 %) and gelatinmore » sponge in one procedure (20 %).ResultsEmbolization resulted in angiographic stasis of flow in all seven procedures. Four women (80 %) presented with vaginal bleeding which was improved after treatment. One woman returned 24 days after unilateral embolization with recurrent bleeding, which resolved after retreatment. One woman underwent two treatments for an asymptomatic lesion identified on ultrasound. There were no major complications. Three women (60 %) experienced mild postembolization pelvic pain that was controlled with non-steroidal anti-inflammatory drugs. Three women (60 %) had pregnancies and deliveries after embolization.ConclusionsTAE is a safe alternative to surgical therapy for acquired uterine AVMs with the potential to maintain fertility. Experience from this case series suggests that NBCA provides predictable and effective occlusion.« less

  18. In situ precise electrospinning of medical glue fibers as nonsuture dural repair with high sealing capability and flexibility.

    PubMed

    Lv, Fu-Yan; Dong, Rui-Hua; Li, Zhao-Jian; Qin, Chong-Chong; Yan, Xu; He, Xiao-Xiao; Zhou, Yu; Yan, Shi-Ying; Long, Yun-Ze

    In this work, we propose an in situ precise electrospinning of medical glue fibers onto dural wound for improving sealing capability, avoiding tissue adhesion, and saving time in dural repair. N-octyl-2-cyanoacrylate, a commercial tissue adhesive (medical glue), can be electrospun into ultrathin fibrous film with precise and homogeneous deposition by a gas-assisted electrospinning device. The self-assembled N-octyl-2-cyanoacrylate film shows high compactness and flexibility owing to its fibrous structure. Simulation experiments on egg membranes and goat meninges demonstrated that this technology can repair small membrane defects quickly and efficiently. This method may have potential application in dural repair, for example, working as an effective supplementary technique for conventional dura suture.

  19. Dosimetric measurements of an n-butyl cyanoacrylate embolization material for arteriovenous malformations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Labby, Zacariah E., E-mail: zelabby@humonc.wisc.edu; Chaudhary, Neeraj; Gemmete, Joseph J.

    2015-04-15

    Purpose: The therapeutic regimen for cranial arteriovenous malformations often involves both stereotactic radiosurgery and endovascular embolization. Embolization agents may contain tantalum or other contrast agents to assist the neurointerventionalists, leading to concerns regarding the dosimetric effects of these agents. This study investigated dosimetric properties of n-butyl cyanoacrylate (n-BCA) plus lipiodol with and without tantalum powder. Methods: The embolization agents were provided cured from the manufacturer with and without added tantalum. Attenuation measurements were made for the samples and compared to the attenuation of a solid water substitute using a 6 MV photon beam. Effective linear attenuation coefficients (ELAC) were derivedmore » from attenuation measurements made using a portal imager and derived sample thickness maps projected in an identical geometry. Probable dosimetric errors for calculations in which the embolized regions are overridden with the properties of water were calculated using the ELAC values. Interface effects were investigated using a parallel plate ion chamber placed at set distances below fixed samples. Finally, Hounsfield units (HU) were measured using a stereotactic radiosurgery CT protocol, and more appropriate HU values were derived from the ELAC results and the CT scanner’s HU calibration curve. Results: The ELAC was 0.0516 ± 0.0063 cm{sup −1} and 0.0580 ± 0.0091 cm{sup −1} for n-BCA without and with tantalum, respectively, compared to 0.0487 ± 0.0009 cm{sup −1} for the water substitute. Dose calculations with the embolized region set to be water equivalent in the treatment planning system would result in errors of −0.29% and −0.93% per cm thickness of n-BCA without and with tantalum, respectively. Interface effects compared to water were small in magnitude and limited in distance for both embolization materials. CT values at 120 kVp were 2082 and 2358 HU for n-BCA without and with tantalum

  20. Percutaneous Direct Needle Puncture and Transcatheter N-butyl Cyanoacrylate Injection Techniques for the Embolization of Pseudoaneurysms and Aneurysms of Arteries Supplying the Hepato-pancreato-biliary System and Gastrointestinal Tract

    PubMed Central

    Yadav, Rajanikant R; Boruah, Deb K; Bhattacharyya, Vishwaroop; Prasad, Raghunandan; Kumar, Sheo; Saraswat, V A; Kapoor, V K; Saxena, Rajan

    2016-01-01

    Aims: The aim of this study was to evaluate the safety and clinical efficacy of percutaneous direct needle puncture and transcatheter N-butyl cyanoacrylate (NBCA) injection techniques for the embolization of pseudoaneurysms and aneurysms of arteries supplying the hepato-pancreato-biliary (HPB) system and gastrointestinal (GI) tract. Subjects and Methods: A hospital-based cross-sectional retrospective study was conducted, where the study group comprised 11 patients with pseudoaneurysms/aneurysms of arteries supplying the HPB system and GI tract presenting to a tertiary care center from January 2015 to June 2016. Four patients (36.4%) underwent percutaneous direct needle puncture of pseudoaneurysms with NBCA injection, 3 patients (27.3%) underwent transcatheter embolization with NBCA as sole embolic agent, and in 4 patients (36.4%), transcatheter NBCA injection was done along with coil embolization. Results: This retrospective study comprised 11 patients (8 males and 3 females) with mean age of 35.8 years ± 1.6 (standard deviation [SD]). The mean volume of NBCA: ethiodized oil (lipiodol) mixture injected by percutaneous direct needle puncture was 0.62 ml ± 0.25 (SD) (range = 0.5–1 ml), and by transcatheter injection, it was 0.62 ml ± 0.37 (SD) (range = 0.3–1.4 ml). Embolization with NBCA was technically and clinically successful in all patients (100%). No recurrence of bleeding or recurrence of pseudoaneurysm/aneurysm was noted in our study. Conclusions: Percutaneous direct needle puncture of visceral artery pseudoaneurysms and NBCA glue injection and transcatheter NBCA injection for embolization of visceral artery pseudoaneurysms and aneurysms are cost-effective techniques that can be used when coil embolization is not feasible or has failed. PMID:28123838

  1. Portal Vein Embolization before Right Hepatectomy: Improved Results Using n-Butyl-Cyanoacrylate Compared to Microparticles Plus Coils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guiu, Boris, E-mail: boris.guiu@chu-dijon.fr; Bize, Pierre; Gunthern, Daniel

    Background: There is currently no consensus in the literature on which embolic agent induces the greatest degree of liver hypertrophy after portal vein embolization (PVE). Only experimental results in a pig model have demonstrated an advantage of n-butyl-cyanoacrylate (NBCA) over 3 other embolic materials (hydrophilic gel, small and large polyvinyl alcohol particles) for PVE. Therefore, the aim of this human study was to retrospectively compare the results of PVE using NBCA with those using spherical microparticles plus coils. Methods: A total of 34 patients underwent PVE using either NBCA (n = 20), or spherical microparticles plus coils (n = 14).more » PVE was decided according to preoperative volumetry on the basis of contrast-enhanced CT. Groups were compared for age, sex, volume of the left lobe before PVE and future remnant liver ratio (FRL) (volume of the left lobe/total liver volume - tumor volume). The primary end point was the increase in left lobe volume 1 month after PVE. Secondary end points were procedure complications and biological tolerance. Results: Both groups were similar in terms of age, sex ratio, left lobe volume, and FRL before PVE. NBCA induced a greater increase in volume after PVE than did microparticles plus coils (respectively, +74 {+-} 69 % and +23 {+-} 14 %, p < 0.05). The amount of contrast medium used for the procedure was significantly larger when microparticles and coils rather than NBCA were used (respectively, 264 {+-} 43 ml and 162 {+-} 34 ml, p < 0.01). The rate of PVE complications as well as the biological tolerance was similar in both groups. Conclusion: NBCA seems more effective than spherical microparticles plus coils to induce left-lobe hypertrophy.« less

  2. Protective effects of poly (butyl) cyanoacrylate nanoparticles containing vasoactive intestinal peptide against 6-hydroxydopamine-induced neurotoxicity in vitro.

    PubMed

    Xu, Zhi-Ran; Wang, Wu-Fang; Liang, Xin-Fang; Liu, Ze-Hua; Liu, Yu; Lin, Liang; Zhu, Xuan

    2015-04-01

    The present study investigated brain delivery system of vasoactive intestinal peptide (VIP) adsorbed on poly (butyl cyanoacrylate) nanoparticles coated with polysorbate 80 (P80-poly (butyl) cyanoacrylate (PBCA)-nanoparticles (NPs)) and the neuroprotective effects on the formulation in the model of 6-hydroxydopamine (6-OHDA)-induced Parkinsonian dysfunction in the human neuroblastoma cell line SH-SY5Y. Drug-loaded nanoparticles were prepared by emulsion polymerization method using VIP and PBCA and then stirring with polysorbate 80. The resulting nanoparticles possessed high entrapment efficiency and favorable stability against CaCl2 or fetal bovine serum (FBS)-induced aggregation. Use of fluorescein isothiocyanate (FITC)-conjugated polysorbate 80-PBCA nanoparticles in confocal microscopy revealed that nanoparticles are located inside, while the FITC solution could not penetrate into the cells. The blank nanoparticles showed no significant effects on cell viability, indicating that they had no role in protection; however, polysorbate 80-modified VIP-loading PBCA nanoparticles showed enhanced cell viability compared to free VIP in 6-OHDA-mimic cellular model of Parkinson's disease. In addition, the nanoparticles strikingly increased the anti-apoptosis activity and restored the loss of mitochondrial membrane potential (MMP) significantly after the treatment of 6-OHDA. These results demonstrated that the activity of VIP was enhanced by polysorbate 80-PBCA nanoparticles compared to control solutions, suggesting that PBCA nanoparticles coated with polysorbate 80 could be an effective carrier system for VIP.

  3. Superselective Embolization for Arterial Upper Gastrointestinal Bleeding Using N-Butyl Cyanoacrylate: A Single-Center Experience in 152 Patients.

    PubMed

    Hur, Saebeom; Jae, Hwan Jun; Lee, Hyukjoon; Lee, Myungsu; Kim, Hyo-Cheol; Chung, Jin Wook

    2017-12-01

    To evaluate 30-day safety and efficacy of superselective embolization for arterial upper gastrointestinal bleeding (UGIB) using N-butyl cyanoacrylate (NBCA). This single-center retrospective 10-year study included 152 consecutive patients with UGIB (gastric, n = 74; duodenal, n = 78) who underwent embolization with NBCA for angiographically positive arterial bleeding. The primary endpoint was clinical success rate defined as achievement of hemostasis without rebleeding or UGIB-related mortality within 30 days after embolization. Mean systolic blood pressure and heart rate were 121.2 mm Hg ± 27.4 and 97.9 beats/minute ± 22.5; 31.1% of patients needed intravenous inotropes, and 36.6% had coagulopathy. The etiology of bleeding was ulcer (80.3%) or iatrogenic injury (19.7%). Statistical analysis was performed to identify predictive factors for outcomes. Technical success rate was 100%. Clinical success, 1-month mortality, and major complication rates were 70.4%, 22.4%, and 0.7%. There were significant differences in the clinical success rates between gastric and duodenal bleeding (79.4% vs 62.2%; P = .025). The need for intravenous inotropes at the time of embolization was a significant negative predictive factor in both gastric (odds ratio [OR] = 0.091, P = .004) and duodenal (OR = 0.156, P = .002) bleeding. The use of a microcatheter with a smaller tip (2 F) was associated with better outcomes in duodenal bleeding (OR = 7.389, P = .005). Superselective embolization using NBCA is safe and effective for angiographically positive arterial UGIB. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  4. High-grade traumatic torso visceral injury with hemodynamic instability: effectiveness of transarterial embolization using n-butyl cyanoacrylate.

    PubMed

    Tsurukiri, Junya; Ohta, Shoichi; Hoshiai, Akira; Sano, Hidefumi; Okumura, Eitaro; Tsubouchi, Nobuhiko; Konishi, Hiroyuki; Yukioka, Tetsuo

    2017-04-01

    Trauma patients with uncontrolled hemorrhage encountering coagulopathy are often associated with poor outcome. Recently, the concept of damage control interventional radiology, which focuses on "speedy stoppage of bleeding" by interventional radiology among trauma patients with hemodynamic instability and acute traumatic coagulopathy, was proposed as an alternative to damage control surgery. N-butyl cyanoacrylate (NBCA) has been used as a liquid embolic agent in various non-traumatic situations, where it has been shown to have a high technical success rate and low recurrent bleeding rate, especially in patients with coagulopathy. In this case, we treated a young patient with hemodynamic instability caused by a high-grade hepatic injury, who underwent arterial embolization (AE) using NBCA assisted with resuscitative endovascular balloon occlusion of the aorta and achieved successful hemostasis. A review of published works using PUBMED was carried out, and 10 published reports involving 23 trauma patients who underwent AE using NBCA were identified. Among them, only four reports involving five trauma patients with torso visceral injuries were identified. Three of five patients who were hemodynamically unstable underwent AE using NBCA, resulting in the stabilization of hemodynamics. We concluded that AE with resuscitative endovascular balloon occlusion of the aorta as a damage control interventional radiology procedure might be acceptable for the hemodynamically unstable hepatic injury, and NBCA could be one of the effective hemostatic agents for this purpose, in cases of trauma-induced coagulopathy.

  5. Fibrin glue in ophthalmology

    PubMed Central

    Panda, Anita; Kumar, Sandeep; Kumar, Abhiyan; Bansal, Raseena; Bhartiya, Shibal

    2009-01-01

    Suturing is a time consuming task in ophthalmology and suture induced irritation and redness are frequent problems. Postoperative wound infection and corneal graft rejection are examples of possible suture related complications. To prevent these complications, ophthalmic surgeons are switching to sutureless surgery. A number of recent developments have established tissue adhesives like cyanoacrylate glue and fibrin glue as attractive alternatives to sutures. A possible and promising new application for tissue adhesives is to provide a platform for tissue engineering. Currently, tissue glue is being used for conjunctival closure following pterygium and strabismus surgery, forniceal reconstruction surgery, amniotic membrane transplantation, lamellar corneal grafting, closure of corneal perforations and descematoceles, management of conjunctival wound leaks after trabeculectomy, lid surgery, adnexal surgery and as a hemostat to minimise bleeding. The purpose of this review is to discuss the currently available information on fibrin glue. PMID:19700876

  6. Molecular dynamics simulations for the examination of mechanical properties of hydroxyapatite/ poly α-n-butyl cyanoacrylate under additive manufacturing.

    PubMed

    Wang, Yanen; Wei, Qinghua; Pan, Feilong; Yang, Mingming; Wei, Shengmin

    2014-01-01

    Molecular dynamics (MD) simulations emerged to be a helpful tool in the field of material science. In rapid prototyping artificial bone scaffolds process, the binder spraying volume and mechanism are very important for bone scaffolds mechanical properties. In this study, we applied MD simulations to investigating the binding energy of α-n-butyl cyanoacrylate (NBCA) on Hydroxyapatite (HA) crystallographic planes (001, 100 and 110), and to calculating and analyzing the mechanical properties and radial distribution function of the HA(110)/NBCA mixed system. The simulation results suggested that HA (110) has the highest binding energy with NBCA owing to the high planar atom density, and the mechanical properties of HA(110)/NBCA mixed system is stronger than pure HA system. Therefore, the multi-grade strength bone scaffold could be fabricated through spraying various volume NBCA binders during 3D printing process. By calculating the radial distribution function of HA(110)/NBCA, the essence of the interface interaction were successfully elucidated. The forming situation parameters can be referred to calculation results. There exists a strong interaction between HA crystallographic plane (110) and NBCA, it is mainly derived from the hydrogen bonds between O atoms which connect with C atoms of NBCA and H atoms in HA crystal. Furthermore, a strong adsorption effect can be demonstrated between HA and NBCA.

  7. Internal Maxillary Artery Preoperative Embolization Using n-Butyl Cyanoacrylate and Pushable Coils for Temporomandibular Joint Ankylosis Surgery.

    PubMed

    Alderazi, Yazan J; Shastri, Darshan; Wessel, John; Mathew, Melvin; Kass-Hout, Tareq; Aziz, Shahid R; Prestigiacomo, Charles J; Gandhi, Chirag D

    2017-05-01

    Temporomandibular joint (TMJ) ankylosis causes disability through impaired digestion, mastication, speech, and appearance. Surgical treatment increases range of motion with resultant functional improvement. However, substantial perioperative blood loss can occur (up to 3 L) if the internal maxillary artery (IMAX) is injured as it traverses the ankylotic mass. Achieving hemostasis is difficult because of limited proximal IMAX access and poor visualization. Our aim is to investigate the technical feasibility and preliminary safety of preoperative IMAX embolization in patients undergoing TMJ ankylosis surgery. Case series using chart reviews of 2 patients who underwent preoperative embolization before TMJ ankylosis surgery. Both patients were women (28 and 51 years old) who had severely restricted mouth opening. Embolization was performed using general anesthesia with nasal intubation on the same day of TMJ surgery. Both patients underwent bilateral IMAX embolization using pushable coils (Vortex, Boston Scientific) of distal IMAX followed by n-butyl-cyanoacrylate (Trufill, Cordis) embolization from coil mass up to proximal IMAX. There were no complications from the embolization procedures. Both patients had normal neurologic examination results. TMJ surgery occurred with minimal operative blood loss (≤300 mL for each surgery). Maximum postoperative mouth opening was 35 mm and 34 mm, respectively. One patient had a postoperative TMJ wound infection that was managed with antibiotics. Preoperative IMAX embolization before TMJ ankylosis surgery is technically feasible with encouraging preliminary safety. There were no complications from the embolization procedures and surgeries occurred with low volumes of blood loss. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Rejoining of cut wounds by engineered gelatin-keratin glue.

    PubMed

    Thirupathi Kumara Raja, S; Thiruselvi, T; Sailakshmi, G; Ganesh, S; Gnanamani, A

    2013-08-01

    Rejoining of cut tissue ends of a critical site challenges clinicians. The toxicity, antigenicity, low adhesive strength, flexibility, swelling and cost of the currently employed glue demands an alternative. Engineered gelatin-keratin glue (EGK-glue) described in the present study was found to be suitable for wet tissue approximation. EGK-glue was prepared by engineering gelatin with caffeic acid using EDC and conjugating with keratin by periodate oxidation. UV-visible, (1)H NMR and circular dichroism analyses followed by experiments on gelation time, rheology, gel adhesive strength (in vitro), wet tissue approximation (in vivo), H&E staining of tissue sections at scheduled time intervals and tensile strength of the healed skin were carried out to assess the effectiveness of the EGK-glue in comparison with fibrin glue and cyanoacrylate. Results of UV-visible, NMR and CD analyses confirmed the functionalization and secondary structural changes. Increasing concentration of keratin reduces the gelation time (<15s). Lap-shear test demonstrates the maximum adhesive strength of 16.6±1.2kPa. Results of hemocompatibility and cytocompatibility studies suggested the suitability of the glue for clinical applications. Tissue approximation property assessed using the incision wound model (Wistar strain) in comparison with cyanoacrylate and fibrin glue suggested, that EGK-glue explicitly accelerates the rejoining of tissue with a 1.86 fold increase in skin tensile strength after healing. Imparting quinone moiety to gelatin-keratin conjugates through caffeic acid and a weaker oxidizing agent provides an adhesive glue with appreciable strength, and hemocompatible, cytocompatible and biodegradable properties, which, rejoin the cut tissue ends effectively. EGK-glue obtained in the present study finds wide biomedical/clinical applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. [Chemical hazards when working with solvent glues].

    PubMed

    Domański, Wojciech; Makles, Zbigniew

    2012-01-01

    Solvent glues are used in a wide variety of industries, e.g., textile, footwear and rubber. The problem of workers' exposure to solvent vapors is rarely tackled within the area of occupational safety and health in small and medium-sized enterprises. In order to assess exposure to solvents, organic solvents emitted by glues were identified in the samples of workplace air. The concentration of acetone, benzene, cyclohexane, ethylbenzene, n-hexane, methylcyclohexane, butyl acetate and toluene were determined. The obtained results evidenced the presence of cyclohexane, ethylbenzene, ethylcyclohexane, heptane, n-hexane, o-xylene, methylcyclohexane, methylcyclopentane, butyl acetate and toluene in workplace air. The concentration of those compounds in workplace air was low, usually below 0.15 of MAC. At some workstations the presence of benzene was also observed. Occupational risk was assessed at workstations where gluing took place. It showed that the risk at those workstations was medium or low.

  10. Venous vascular malformations of the craniofacial region: pre-operative embolisation with direct percutaneous puncture and N-butyl cyanoacrylate.

    PubMed

    Cil, B E; Vargel, I; Geyik, S; Peynircioglu, B; Cavusoglu, T

    2008-12-01

    Craniofacial venous vascular malformations cause severe cosmetic problems and yet these lesions are not candidates for transcatheter embolisation owing to the lack of arterial feeders. The purpose of this study was to evaluate the effectiveness of pre-operative embolisation of these lesions with N-butyl 2-cyanoacrylate (NBCA) via direct puncture. Between September 2003 and April 2006, 13 patients (7 female; age range, 6-64 years; mean, 16.7 years) were embolised with direct puncture and injection of NBCA. All of the patients were referred from plastic surgery with an operational plan. Angiography performed in all patients showed no or little arterial staining. NBCA diluted with iodized oil at a ratio of 1:6 (18%) was injected via a percutaneously placed 21 gauge needle. Complete embolisation was achieved in 8 patients and partial embolisation in the remaining 5. A total of 18 sessions of embolisation were performed on 13 patients. Nine patients underwent only one embolisation session, three patients underwent two sessions and only one patient underwent three sessions. The mean volume of NBCA used per session was 5.8 ml, ranging from 1-12 ml. All patients underwent a successful surgical resection to improve cosmetic disfigurement within 10-15 days after the embolisation procedure. Mean follow-up time was 22 months. One patient experienced skin necrosis on her nose after embolisation. No other complications related to the procedure were observed. In conclusion, pre-operative NBCA embolisation with direct puncture is a safe and easy procedure. It can increase the success of the surgical treatment of these lesions.

  11. Ischemic Effects of Transcatheter Arterial Embolization with N-Butyl Cyanoacrylate-Lipiodol on the Colon in a Swine Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ikoma, Akira; Kawai, Nobuyuki; Sato, Morio, E-mail: morisato@wakayama-med.ac.jp

    2010-10-15

    This study was designed to assess the safety of transcatheter arterial embolization (TAE) with n-butyl cyanoacrylate-lipiodol (NBCA-Lp) for the large bowel and to investigate the vital response to NBCA-Lp in a swine model. In nine swine, nine arteries nourishing the colon were embolized with NBCA-Lp (1 ml of NBCA mixed with 4 ml of lipiodol): sigmoid-rectal branch artery in six swine, right colic branch artery in two, and middle colic branch artery in one. The amount of NBCA-Lp was 0.1-0.4 ml. Sacrifice was conducted 3 days after TAE to identify histological infarction. Classification was conducted retrospectively: group A, vasa rectamore » without NBCA-Lp embolization despite TAE; group B, three or fewer vasa recta with NBCA-Lp embolization; and group C, five or more vasa recta with NBCA-Lp embolization. In one swine in group A, no necrotic focus was observed. In group B, three of four swine experienced no ischemic damage. The remaining one swine experienced necrosis of mucosal and submucosal layers in one-fourth of the circumference. In group C, all four swine with marginal artery and five vasa recta or more embolized experienced total necrosis of mucosa, submucosa, and smooth muscle layers of the whole colonic circumference. Significant difference on the extent of ischemic damage was observed between groups B and C (P < 0.05). Microscopically, NBCA-Lp induced acute vasculitis. Embolization of three or fewer vasa recta with NBCA-Lp induced no ischemic damage or limited necrosis, whereas embolization of five or more vasa recta with NBCA-Lp induced extensive necrosis.« less

  12. A Water-Borne Adhesive Modeled after the Sandcastle Glue of P. californicaa

    PubMed Central

    Shao, Hui; Bachus, Kent N.

    2010-01-01

    Polyacrylate glue protein analogs of the glue secreted by Phragmatopoma californica, a marine polycheate, were synthesized with phosphate, primary amine, and catechol sidechains with molar ratios similar to the natural glue proteins. Aqueous mixtures of the mimetic polyelectrolytes condensed into liquid complex coacervates around neutral pH. Wet cortical bone specimens bonded with the coacervates, oxidatively crosslinked through catechol sidechains, had bond strengths nearly 40% of the strength of a commercial cyanoacrylate. The unique material properties of complex coacervates may be ideal for development of clinically useful adhesives and other biomaterials. PMID:19040222

  13. Transcatheter Arterial Embolization for Primary Postpartum Hemorrhage: Predictive Factors of Need for Embolic Material Conversion of Gelatin Sponge Particles to N-Butyl Cyanoacrylate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanahashi, Yukichi; Goshima, Satoshi, E-mail: gossy@par.odn.ne.jp; Kondo, Hiroshi

    PurposeTo identify predictive factors for embolic material conversion to N-butyl cyanoacrylate (NBCA) for the treatment of primary postpartum hemorrhage (PPH) after failed transcatheter arterial embolization (TAE) using gelatin sponge (GS).Materials and MethodsInstitutional review board approval was obtained. We retrospectively studied 62 consecutive women with primary PPH who underwent TAE between January 2006 and March 2015. Five of them were excluded for the following: cardiopulmonary arrest at arrival (n = 1), uterine inversion (n = 1), and hysterectomy after TAE (n = 3). Remaining 57 women (age range, 21–43 years; mean, 32.6 years) comprised study population. TAE was initially performed using GS in all cases andmore » then converted to NBCA after two embolizations using GS with persistent hemodynamic instability or vaginal bleeding. The patients’ background, uterine height, vital signs, laboratory tests, disseminated intravascular coagulation score, and details of procedure were reviewed. Univariate and multivariate analyses were performed to determine factors related to embolic material conversion.ResultsTechnical success rate was 100%. Fourteen patients (25%) needed embolic material conversion to NBCA. Univariate analysis showed that uterine height, systolic blood pressure (sBP), and hemoglobin level were significantly related to embolic material conversion to NBCA (P = 0.029, 0.030, and 0.042). Logistic regression analysis showed that uterine height (odds ratio, 1.37; P = 0.025) and sBP (odds ratio, 0.96; P = 0.003) were associated with embolic material conversion to NBCA.ConclusionUterine height and sBP can be predictive factors for embolic material conversion to NBCA for the treatment of PPH.Level of EvidenceLevel 4, Case Control Study.« less

  14. Transcatheter embolization of pancreatic arteriovenous malformation associated with recurrent acute pancreatitis

    PubMed Central

    Rajesh, S; Mukund, Amar; Bhatia, Vikram; Arora, Ankur

    2016-01-01

    Pancreatic arteriovenous malformation (PAVM) is extremely rare; even rarer is its association with pancreatitis. The authors report a case of PAVM causing recurrent episodes of acute pancreatitis in a 46-year-old male. Patient refused surgery and was treated with transcatheter arterial embolization using liquid embolic agent (mixture of n-butyl-2-cyanoacrylate glue and lipiodol), which resulted in a significant decrease in the size of the PAVM. PMID:27081231

  15. General Characteristics and Cytotoxic Effects of Nano-Poly (Butyl Cyanoacrylate) Containing Carboplatin on Ovarian Cancer Cells

    PubMed Central

    Kanaani, Leila; Far, Meysam Ebrahimi; Kazemi, S Maryam; Choupani, Edris; Tabrizi, Maral Mazloumi; Shahmabadi, Hasan Ebrahimi; Khiyavi, Azim Akbarzadeh

    2017-01-01

    The initial response to treatment and subsequent development of resistance to carboplatin are very important challenges. Use of nano drug delivery is a new method to replace standard chemotherapy. In this research, both non-PEGylated and PEGylated nanoparticles (NPs) were prepared by mini-emulsion polymerization of poly (butyl cyanoacrylate) (PBCA) NPs. Characteristics such as size, polydispersity index (PDI), zeta potential, drug release, and stability were examined. In addition, infrared spectroscopy was used for description of the produced NPs. Then, cytotoxicity effects of both formulations were studied on the A2780CIS ovarian cancer cell line with incubation for 24, 48, and 72h. Examination of characteristics of loaded carboplatin on the PBCA NPs under suitable laboratory conditions showed a positive effect of PEG on their properties. Cytotoxicity studies demonstrated greater toxicity with both formulations of nano-drugs than the free drug. The results indicated that PBCA NPs can be considered as suitable candidates for nano-drugs in chemotherapy. PMID:28240014

  16. A prospective, multicenter, randomized trial of the Onyx liquid embolic system and N-butyl cyanoacrylate embolization of cerebral arteriovenous malformations. Clinical article.

    PubMed

    Loh, Yince; Duckwiler, Gary R

    2010-10-01

    The Onyx liquid embolic system (Onyx) was approved in the European Union in 1999 for embolization of lesions in the intracranial and peripheral vasculature, including brain arteriovenous malformations (AVMs) and hypervascular tumors. In 2001 a prospective, equivalence, multicenter, randomized controlled trial was initiated to support a submission for FDA approval. The objective of this study was to verify the safety and efficacy of Onyx compared with N-butyl cyanoacrylate (NBCA) for the presurgical treatment of brain AVMs. One hundred seventeen patients with brain AVMs were treated with either Onyx (54 patients) or NBCA (63 patients) for presurgical endovascular embolization between May 2001 and April 2003. The primary end point was technical success in achieving ≥ 50% reduction in AVM volume. Secondary end points were operative blood loss and resection time. All adverse events (AEs) were reported and assigned a relationship to the Onyx or NBCA system, treatment, disease, surgery, or other/unknown. The Data Safety Monitoring Board adjudicated AEs, and a blinded, independent core lab assessed volume measurements. Patients were monitored through discharge after the final surgery or through a 3- and/or 12-month follow-up if resection had not been performed or was incomplete. The use of Onyx led to ≥ 50% AVM volume reduction in 96% of cases versus 85% for NBCA (p = not significant). The secondary end points of resection time and blood loss were similar. Serious AEs were also similar between the 2 treatment groups. Onyx is equivalent to NBCA in safety and efficacy as a preoperative embolic agent in reducing brain AVM volume by at least 50%.

  17. The use of tissue glue in prominent ear correction surgery.

    PubMed

    Patel, Animesh J K; Price, Richard D

    2011-04-01

    Cyanoacrylate tissue glues have been used for many years in otoplasty and specific indications for its use are as described. As well as being an effective means of dressing the postauricular suture line, its use in gluing the pinna back to the postauricular skin may negate the use of the head bandage in the postoperative period.

  18. Portal Vein Embolization Utilizing N-Butyl Cyanoacrylate for Contralateral Lobe Hypertrophy Prior to Liver Resection: A Systematic Review and Meta-Analysis.

    PubMed

    Wajswol, Ethan; Jazmati, Tarek; Contractor, Sohail; Kumar, Abhishek

    2018-04-23

    To evaluate the safety and effectiveness of n-butyl cyanoacrylate (NBCA) for portal vein embolization (PVE) when used to induce contralateral future liver remnant (FLR) hypertrophy in patients undergoing planned hepatic resection for hepatic malignancy. The PubMed database (including articles indexed by MEDLINE) was searched for articles published from 1970 to 2018 describing patients treated with PVE utilizing NBCA to induce hypertrophy of the FLR prior to contralateral hepatic lobe resection. Demographic data, embolization technique, complications of embolization, resultant FLR hypertrophy, and surgical outcomes were obtained when available. A meta-analysis was performed to determine the cumulative relative hypertrophy rate of the FLR following PVE with NBCA. The literature search yielded 18 relevant articles. Six hundred and seven patients (383 men, 220 women; mean age 60.7 years) with procedures describing PVE utilizing NBCA were reviewed. The most common underlying hepatic malignancies were colorectal metastases (n = 348), followed by cholangiocarcinomas (n = 92), and hepatocellular carcinomas (n = 89). Technical success was reportedly achieved in 603/607 patients, for a success rate of 99.3%. Fixed effects meta-analysis of the relative hypertrophy rate of the FLR among studies resulted in an aggregate rate of 49.4 ± 1.3%. Of the patients who underwent attempted PVE, 461/607 (75.9%) eventually underwent surgical resection. Major complications following PVE occurred in 19 patients (3.13%), while minor complications following PVE occurred in 38 patients (6.26%). PVE utilizing NBCA to induce hypertrophy of the FLR prior to contralateral lobe resection in the setting of hepatic malignancy is safe and effective. Level IIa-Systematic review of cohort studies.

  19. Glue versus suture for mesh fixation in inguinal hernia repair.

    PubMed

    Chandrasekar, Shruthi; Jeyakumar, S; Ganapathy, Tharun

    2018-03-22

    glue were used to fix the mesh instead of sutures. The tissue glue used in this study was N Butyl- 2 - Cyanoacrylate. All patients in the study underwent surgery only by one group of surgeons to maintain homogeneity and were observed in the hospital for 72 h. A note of the pain on VAS scale was made at 12, 24, 48, 72 h, 1 week, 1 month, 3 months and 6 months. Operative time and any complications were also recorded. Results developed using SPSS software show that there is a significant difference in the time taken by both the methods, with glue taking a significantly lower time than sutures. Significance is also seen in the difference in the immediate and chronic post-operative pain between both the groups. However the complication rates in both the groups were found to be the same. It can thus be concluded from this study that tissue glue mesh fixation is superior to suture mesh fixation in open inguinal repair in terms of operative time, immediate and chronic post-operative time. Copyright © 2018. Published by Elsevier Ltd.

  20. In situ precision electrospinning as an effective delivery technique for cyanoacrylate medical glue with high efficiency and low toxicity.

    PubMed

    Dong, R H; Qin, C C; Qiu, X; Yan, X; Yu, M; Cui, L; Zhou, Y; Zhang, H D; Jiang, X Y; Long, Y Z

    2015-12-14

    The side effects or toxicity of cyanoacrylate used in vivo have been argued since its first application in wound closure. We propose an airflow-assisted in situ precision electrospinning apparatus as an applicator and make a detailed comparison with traditional spraying via in vitro and in vivo experiments. This novel method can not only improve operational performance and safety by precisely depositing cyanoacrylate fibers onto a wound, but significantly reduce the dosage of cyanoacrylate by almost 80%. A white blood cell count, liver function test and histological analysis prove that the in situ precision electrospinning applicator produces a better postoperative outcome, e.g., minor hepatocyte injury, moderate inflammation and the significant ability for liver regeneration. This in situ precision electrospinning method may thus dramatically broaden both civilian and military applications of cyanoacrylates.

  1. A different type of 'glue ear': report of an unusual case of prominent ears.

    PubMed

    Purcell, Elizabeth M; O'Neill, Ann C; Regan, Padraic J

    2003-09-01

    Prominent ears is a condition that can cause extreme psychological distress in young people. This cosmetic deformity can be corrected by otoplasty, an outpatient surgical procedure that is associated with a high rate of patient satisfaction. We report the unusual case of a teenage boy who had repeatedly applied cyanoacrylate adhesive ("superglue") to his postauricular skin in an attempt to pin back his prominent ears. This case of "glue ear" was ultimately resolved by successful otoplasty, although the residual effects of the glue resulted in delayed healing of the surgical wound.

  2. Glue, steam and Clarivein--Best practice techniques and evidence.

    PubMed

    Whiteley, Mark S

    2015-11-01

    In July 2013, the National Institute of Health and Clinical Excellence (NICE) recommended "endothermal" ablation (meaning endovenous thermal ablation) is the first line treatment for truncal venous reflux in varicose veins. The initial endovenous thermoablation devices were radiofrequency ablation and endovenous laser ablation. More recently, Glue (cyanoacrylate), endovenous steam and Clarivein (mechanochemical ablation or MOCA) have entered the market as new endovenous techniques for the treatment of varicose veins. Glue and Clarivein do not require tumescent anaesthesia and do not use heat and therefore termed non-tumescent non-thermal (NTNT). Steam both requires tumescence and is also a thermal technique (TT). This article reviews the current position of these 3 new technologies in the treatment of varicose veins. © The Author(s) 2015.

  3. Embolization as the treatment for a life-threatening mandibular arteriovenous malformation.

    PubMed

    Loureiro, Caio Cesar de Souza; Falchet, Paula Cristina Felix; Gavranich, João; Lobo Leandro, Luiz Fernando

    2010-03-01

    Mandibular arteriovenous malformation is a severe vascular pathological condition that may lead to life-threatening hemorrhages. In child and teenaged patients, a conservative treatment is preferred to avoid profuse blood loss and/or mutilating alterations in the still-growing patients' face. The aim of this article was to present a case of an 11-year-old boy with an arteriovenous malformation involving the left mandible and treated by means of endovascular embolization with direct lesional delivery of N-butyl-cyanoacrylate glue through transfemoral catheterization.

  4. Glue Embolization of a Blunt Traumatic Hepatic Arteriovenous Fistula under Inflow and Outflow Control.

    PubMed

    Mine, Takahiko; Murata, Satoru; Yasui, Daisuke; Yokota, Hiroyuki; Tajima, Hiroyuki; Kumita, Shin-ichiro

    2016-01-01

    We report on a rare case of blunt traumatic hepatic arteriovenous fistula arising from a pseudoaneurysm in a 35-year-old woman. Transarterial embolization was performed with n-butyl-2-cyanoacrylate, under inflow control with loose coil packing within the pseudoaneurysm and outflow control by balloon occlusion of the hepatic vein. A promising therapeutic outcome was achieved without any serious adverse events. Thus, the combination of these techniques to control inflow and outflow was successfully used to treat this rare hepatic vascular injury.

  5. A unique and unexplained ricochet leak post PCI - successfully treated with intra-coronary glue.

    PubMed

    Goel, Pravin K; Syal, Sanjeev K

    2014-01-01

    We herein describe a unique case of coronary artery perforation treated with covered stent with repeat cardiac tamponade resulting out of a fresh unexplained leak from a remote vessel (Ricochet) and successfully treated with intra-coronary injection of sterile synthetic glue, cyanoacrylate. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  6. Strong tissue glue with tunable elasticity.

    PubMed

    Kelmansky, Regina; McAlvin, Brian J; Nyska, Abraham; Dohlman, Jenny C; Chiang, Homer H; Hashimoto, Michinao; Kohane, Daniel S; Mizrahi, Boaz

    2017-04-15

    Many bio-adhesive materials adhere weakly to tissue due to their high water content and weak structural integrity. Others provide desirable adhesive strength but suffer from rigid structure and lack of elasticity after administration. We have developed two water-free, liquid four-armed PEG pre-polymers modified with NHS or with NH 2 end groups which upon mixing changed from liquids to an elastic solid. The sealant and adhesive properties increased with the amount of the %v/v PEG 4 -NHS pre-polymer, and achieved adhesive properties comparable to those of cyanoacrylate glues. All mixtures showed minimal cytotoxicity in vitro. Mixtures of 90%v/v PEG 4 -NHS were retained in the subcutaneous space in vivo for up to 14days with minimal inflammation. This material's combination of desirable mechanical properties and biocompatibility has potential in numerous biomedical applications. Many bio-adhesive materials adhere weakly to tissue (e.g. hydrogels) due to their high water content and weak structural integrity. Others provide desirable mechanical properties but suffer from poor biocompatibility (e.g. cyanoacrylates). This study proposes a new concept for the formation of super strong and tunable tissue glues. Our bio-materials' enhanced performance is the product of new neat (without water or other solvents) liquid polymers that solidify after administration while allowing interactions with the tissue. Moreover, the elastic modulus of these materials could easily be tuned without compromising biocompatibility. This system could be an attractive alternative to sutures and staples since it can be applied more quickly, causes less pain and may require less equipment while maintaining the desired adhesion strength. Copyright © 2017 Acta Materialia Inc. All rights reserved.

  7. Brain targeting of nerve growth factor using poly(butyl cyanoacrylate) nanoparticles.

    PubMed

    Kurakhmaeva, Kamila B; Djindjikhashvili, Irma A; Petrov, Valery E; Balabanyan, Vadim U; Voronina, Tatiana A; Trofimov, Sergey S; Kreuter, Jörg; Gelperina, Svetlana; Begley, David; Alyautdin, Renad N

    2009-09-01

    The nerve growth factor (NGF) is essential for the survival of both peripheral ganglion cells and central cholinergic neurons in the basal forebrain. The accelerated loss of central cholinergic neurons during Alzheimer's disease may be a determinant cause of dementia, and this observation may suggest a possible therapeutic benefit from treatment with NGF. In recent years, convincing data have been published involving neurotrophic factors for the modulation of dopaminergic transmission within the brain and concerning the ability of NGF to prevent the degeneration of dopaminergic neurons. In this connection, the administration of NGF may slow down the progression of Parkinson's disease. However, NGF, as well as other peptidic neurotrophic factors, does not significantly penetrate the blood-brain barrier (BBB) from the circulation. Therefore, any clinical usefulness of NGF as a potential CNS therapy will depend on the use of a suitable carrier system that enhances its transport through the BBB. The present study investigates brain delivery of NGF adsorbed on poly(butyl cyanoacrylate) (PBCA) nanoparticles coated with polysorbate 80 and the pharmacological efficacy of this delivery system in the model of acute scopolamine-induced amnesia in rats as well as in the model of 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-induced Parkinsonian syndrome. As shown by the passive avoidance reflex (PAR) test, the intravenous administration of the nanoparticle-bound NGF successfully reversed scopolamine-induced amnesia and improved recognition and memory. This formulation also demonstrated a significant reduction of the basic symptoms of Parkinsonism (oligokinesia, rigidity, tremor). In addition, the efficient transport of NGF across the BBB was confirmed by direct measurement of NGF concentrations in the murine brain. These results demonstrate that the PBCA nanoparticles coated with polysorbate 80 are an effective carrier system for the transport of NGF to the central

  8. Safety and efficacy of transcatheter embolization with Glubran®2 cyanoacrylate glue for acute arterial bleeding: a single-center experience with 104 patients.

    PubMed

    Abdulmalak, Gilles; Chevallier, Olivier; Falvo, Nicolas; Di Marco, Lucy; Bertaut, Aurélie; Moulin, Benjamin; Abi-Khalil, Célina; Gehin, Sophie; Charles, Pierre-Emmanuel; Latournerie, Marianne; Midulla, Marco; Loffroy, Romaric

    2018-03-01

    To assess the efficacy and the safety of Glubran ® 2 n-butyl cyanoacrylate metacryloxysulfolane (NBCA-MS) transcatheter arterial embolization (TAE) for acute arterial bleeding from varied anatomic sites and to evaluate the predictive factors associated with clinical success and 30-day mortality. A retrospective review of consecutive patients who underwent emergent NBCA-MS Glubran ® 2 TAE between July 2014 and August 2016 was conducted. Variables including age, sex, underlying malignancy, cardiovascular comorbidities, coagulation data, systolic blood pressure, and number of red blood cells units (RBC) transfused before TAE were collected. Clinical success, 30-day mortality, and complication rates were evaluated. Prognostic factors were evaluated by uni- and multivariate logistic regression analyses for clinical success, and by uni- and bivariate analyses after adjustment by bleeding sites for 30-day mortality. 104 patients underwent technically successful embolization with bleeding located in muscles (n = 34, 32.7%), digestive tract (n = 28, 26.9%), and viscera (n = 42, 40.4%). Clinical success rate was 76% (n = 79) and 30-day mortality rate was 21.2% (n = 22). Clinical failure was significantly associated with mortality (p < 0.0001). A number of RBC units transfused greater than or equal to 3 were associated with poorer clinical success (p = 0.025) and higher mortality (p = 0.03). Complications (n = 4, 3.8%) requiring surgery occurred only at puncture site. No ischemic complications requiring further invasive treatment occurred. Mean TAE treatment time was 4.55 min. NBCA-MS Glubran ® 2 TAE is a fast, effective, and safe treatment for acute arterial bleeding whatever the bleeding site.

  9. Comparison of hemostatic durability between N-butyl cyanoacrylate and gelatin sponge particles in transcatheter arterial embolization for acute arterial hemorrhage in a coagulopathic condition in a swine model.

    PubMed

    Yonemitsu, Takafumi; Kawai, Nobuyuki; Sato, Morio; Sonomura, Tetsuo; Takasaka, Isao; Nakai, Motoki; Minamiguchi, Hiroki; Sahara, Shinya; Iwasaki, Yasuhiro; Naka, Toshio; Shinozaki, Masahiro

    2010-12-01

    This study was designed to compare the efficacy of transcatheter arterial embolization (TAE) with N-butyl cyanoacrylate (NBCA) or gelatin sponge particles (GSP) for acute arterial bleeding in a coagulopathic condition using a swine model. Four healthy swine were divided into two coagulopathic conditions: mild and severe. Five hemorrhages were created in each swine (10 hemorrhages per coagulopathy). Mild coagulopathy was achieved by bloodletting 10% of the total circulatory whole blood and preserving activated clotting time (ACT) less than 200 s (ACT < 200 s state); severe coagulopathy was achieved by bloodletting 30% and preserving ACT > 400 s (ACT > 400-second state). For each state, of ACT < 200 s or ACT > 400 s, TAE was conducted with GSP or NBCA to control five hemorrhages arising from artificially created renal and splenic injuries. Angiography immediately after TAE with GSP or NBCA showed complete occlusion in both coagulopathic conditions. In the ACT < 200-second state, follow-up angiography at 5-30 min after TAE with GSP or NBCA showed no evidence of recurrent hemorrhage. In the ACT > 400-second state, follow-up angiography showed recurrent hemorrhage in four (80%) of the five hemorrhages embolized with GSP and in one (20%) of the five hemorrhages embolized with NBCA. Microscopically, red thrombi were observed densely surrounding GSP in mild coagulopathy but were scarce in severe coagulopathy. In a condition with severe coagulopathy, TAE with NBCA was more effective in durability to cease active arterial bleeding than with GSP.

  10. Embolization of a True Giant Splenic Artery Aneurysm Using NBCA Glue - Case Report and Literature Review.

    PubMed

    Guziński, Maciej; Kurcz, Jacek; Kukulska, Monika; Neska, Małgorzata; Garcarek, Jerzy

    2015-01-01

    Although splenic artery aneurysms (SAAs) are common, their giant forms (more than 10 cm in diameter) are rare. Because of the variety of forms and locations of these aneurysms, there are a lot of therapeutic methods to choose. In our case of a giant true aneurysm we performed an endovascular embolization with N-butyl-cyano-acrylate (NBCA) glue. To our knowledge it is the first reported case of this method of treatment of true giant SAA. A 74-year-old male patient with symptomatic giant SAA (13 cm) was urgently admitted to our hospital for the diagnostic and therapeutic procedures. Due to the general health condition, advanced age and the large size of the aneurysm we decided to perform an endovascular treatment with N-butyl-cyano-acrylate (NBCA) glue. The preaneurysmal part of splenic artery was occluded completely with exclusion of the aneurysm. No splenectomy was needed. The patient was discharged in good general condition Embolization with NBCA can be an efficient method to treat the giant SAA.

  11. Percutaneous Treatment of Iatrogenic Pseudoaneurysms by Cyanoacrylate-Based Wall-Gluing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Del Corso, Andrea, E-mail: adelcorso2000@hotmail.com; Vergaro, Giuseppe

    Purpose. Although the majority of iatrogenic pseudoaneurysms (PSAs) are amenable to ultrasound (US)-guided thrombin injection, patients with those causing neuropathy, claudication, significant venous compression, or soft tissue necrosis are considered poor candidates for this option and referred to surgery. We aimed to test the effectiveness and feasibility of a novel percutaneous cyanoacrylate glue (NBCA-MS)-based technique for treatment of symptomatic and asymptomatic iatrogenic PSA. Material and Methods. During a 3-year period, we prospectively enrolled 91 patients with iatrogenic PSA [total n = 94 (femoral n = 76; brachial n = 11; radial n = 6; axillary n = 1)]. PSA weremore » asymptomatic in 66 % of cases, and 34 % presented with symptoms due to neuropathy, venous compression, and/or soft tissue necrosis. All patients signed informed consent. All patients received NBCA-MS-based percutaneous treatment. PSA chamber emptying was first obtained by US-guided compression; superior and inferior walls of the PSA chamber were then stuck together using NBCA-MS microinjections. Successfulness of the procedure was assessed immediately and at 1-day and 1-, 3-, and 12-month US follow-up. Results. PSA occlusion rate was 99 % (93 of 94 cases). After treatment, mean PSA antero-posterior diameter decrease was 67 {+-} 22 %. Neuropathy and vein compression immediately disappeared in 91 % (29 of 32) of cases. Patients with tissue necrosis (n = 6) underwent subsequent outpatient necrosectomy. No distal embolization occurred, nor was conversion to surgery necessary. Conclusion. PSA treatment by way of NBCA-MS glue injection proved to be safe and effective in asymptomatic patients as well as those with neuropathy, venous compression, or soft-tissue necrosis (currently candidates for surgery). Larger series are needed to confirm these findings.« less

  12. Comparison of Hemostatic Durability between N-Butyl Cyanoacrylate and Gelatin Sponge Particles in Transcatheter Arterial Embolization for Acute Arterial Hemorrhage in a Coagulopathic Condition in a Swine Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yonemitsu, Takafumi; Kawai, Nobuyuki; Sato, Morio, E-mail: morisato@mail.wakayama-med.ac.jp

    2010-12-15

    This study was designed to compare the efficacy of transcatheter arterial embolization (TAE) with N-butyl cyanoacrylate (NBCA) or gelatin sponge particles (GSP) for acute arterial bleeding in a coagulopathic condition using a swine model. Four healthy swine were divided into two coagulopathic conditions: mild and severe. Five hemorrhages were created in each swine (10 hemorrhages per coagulopathy). Mild coagulopathy was achieved by bloodletting 10% of the total circulatory whole blood and preserving activated clotting time (ACT) less than 200 s (ACT < 200 s state); severe coagulopathy was achieved by bloodletting 30% and preserving ACT > 400 s (ACT >more » 400-second state). For each state, of ACT < 200 s or ACT > 400 s, TAE was conducted with GSP or NBCA to control five hemorrhages arising from artificially created renal and splenic injuries. Angiography immediately after TAE with GSP or NBCA showed complete occlusion in both coagulopathic conditions. In the ACT < 200-second state, follow-up angiography at 5-30 min after TAE with GSP or NBCA showed no evidence of recurrent hemorrhage. In the ACT > 400-second state, follow-up angiography showed recurrent hemorrhage in four (80%) of the five hemorrhages embolized with GSP and in one (20%) of the five hemorrhages embolized with NBCA. Microscopically, red thrombi were observed densely surrounding GSP in mild coagulopathy but were scarce in severe coagulopathy. In a condition with severe coagulopathy, TAE with NBCA was more effective in durability to cease active arterial bleeding than with GSP.« less

  13. 40 CFR 721.4925 - Methyl n-butyl ketone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Methyl n-butyl ketone. 721.4925... Substances § 721.4925 Methyl n-butyl ketone. (a) Chemical substance and significant new use subject to reporting. (1) The chemical substance methyl n-butyl ketone, CAS Number 591-78-6, is subject to reporting...

  14. 40 CFR 721.4925 - Methyl n-butyl ketone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Methyl n-butyl ketone. 721.4925... Substances § 721.4925 Methyl n-butyl ketone. (a) Chemical substance and significant new use subject to reporting. (1) The chemical substance methyl n-butyl ketone, CAS Number 591-78-6, is subject to reporting...

  15. 21 CFR 520.260 - n-Butyl chloride capsules.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false n-Butyl chloride capsules. 520.260 Section 520.260... DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.260 n-Butyl chloride capsules. (a)(1) Specifications. n-Butyl chloride capsules, veterinary contain 272 milligrams or 816 milligrams...

  16. 27 CFR 21.100 - n-Butyl alcohol.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false n-Butyl alcohol. 21.100 Section 21.100 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT....100 n-Butyl alcohol. (a) Acidity (as acetic acid). 0.03 percent by weight maximum. (b) Color...

  17. 27 CFR 21.100 - n-Butyl alcohol.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false n-Butyl alcohol. 21.100 Section 21.100 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT....100 n-Butyl alcohol. (a) Acidity (as acetic acid). 0.03 percent by weight maximum. (b) Color...

  18. 21 CFR 520.260 - n-Butyl chloride.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 6 2014-04-01 2014-04-01 false n-Butyl chloride. 520.260 Section 520.260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.260 n-Butyl chloride. (a)(1...

  19. 21 CFR 520.260 - n-Butyl chloride.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false n-Butyl chloride. 520.260 Section 520.260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.260 n-Butyl chloride. (a)(1...

  20. 40 CFR 721.10193 - 1-Butanaminium, N-(3-aminopropyl)-N-butyl-N-(2-carboxyethyl)-, N-coco acyl derivs., inner salts.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-butyl-N-(2-carboxyethyl)-, N-coco acyl derivs., inner salts. 721.10193 Section 721.10193 Protection of...-aminopropyl)-N-butyl-N-(2-carboxyethyl)-, N-coco acyl derivs., inner salts. (a) Chemical substance and...-aminopropyl)-N-butyl-N-(2-carboxyethyl)-, N-coco acyl derivs., inner salts (PMN P-06-263, Chemical B; CAS No...

  1. 27 CFR 21.118 - Methyl n-butyl ketone.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Methyl n-butyl ketone. 21.118 Section 21.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU....118 Methyl n-butyl ketone. (a) Acidity (as acetic acid). 0.02 percent by weight, maximum. (b) Color...

  2. 27 CFR 21.118 - Methyl n-butyl ketone.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Methyl n-butyl ketone. 21.118 Section 21.118 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU....118 Methyl n-butyl ketone. (a) Acidity (as acetic acid). 0.02 percent by weight, maximum. (b) Color...

  3. 21 CFR 520.260 - n-Butyl chloride capsules.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false n-Butyl chloride capsules. 520.260 Section 520.260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.260 n-Butyl chloride capsules...

  4. Endovascular treatment of isolated systemic arterial supply to normal lung with coil and glue embolisation.

    PubMed

    Anil, G; Taneja, M; Tan, A-G-S

    2012-04-01

    Surgery is the standard treatment for the extremely rare pathology of isolated anomalous systemic arterial supply to normal lung (ISSNL). We describe our experience with this anomaly in a 29-year-old male presenting with recurrent haemoptysis that was successfully treated with a combination of metallic coils and cyanoacrylate glue. In addition to contributing to the extremely limited data on endovascular therapeutic options in ISSNL, we also intend to raise the awareness among endovascular therapists of the need to be cautious ofand preserve the radiculomedullary/pial branches arising from an anomalous artery before embolising it.

  5. Mechanical and chemical characteristics of an autologous glue.

    PubMed

    De Somer, Filip; Delanghe, Joris; Somers, Pamela; Debrouwere, Maarten; Van Nooten, Guido

    2008-09-15

    The study evaluates the mechanical and chemical characteristics of autologous surgical glue made by mixing ultrafiltered plasma with glutaraldehyde (GTA). Human albumin 200 g/L mixed with different concentrations of GTA (25, 50, 75, or 100 g/L) was used as a single protein set-up for testing tensile strength, elasticity, and rate of crosslinking. Subsequently, ultrafiltered canine or human plasma to obtain autologous glue replaced human albumin. BioGlue, a surgical glue, and Tissucol Duo, a fibrin sealant, were used as controls. Tensile strength of human albumin 200 g/L mixed with 75 g/L GTA is 825 +/- 109 N versus 672 +/- 167 N for BioGlue. Ultrafiltered canine plasma showed a maximum tensile strength of 634 +/- 137 N when mixed with GTA 75 g/L. For human plasma, the maximum tensile strength of 436 +/- 69 N was reached after mixing with GTA 25 g/L. Autologous glue had a higher elasticity of 144 +/- 66 N versus 322 +/- 104 N for BioGlue at maximum load. Autologous glues for vascular repair can be easily prepared out of the patient's plasma. The optimal characteristics, compared to BioGlue, are obtained for ultrafiltered canine and human plasma by mixing with a GTA concentration of 50-75 g/L and 25-50 g/L, respectively. The autologous glue will exert less tensile strength than BioGlue but has a better compliance. In case where no plasma can obtained from the patient, mixing human albumin 200 g/L with GTA 75 g/L can be an alternative to BioGlue.

  6. Evaluation of the abdominal wall cicatrization of rabbits exposed to nicotine and undergone abdominoplasty using nylon thread or cyanoacrylate.

    PubMed

    Costa, Luciano Assis; Jardim, Paulo dos Reis; Macedo, Pedro Henrique Alvares Paiva; Amaral, Vânia da Fonseca; Silva, Alcino Lázaro da; Barbosa, Cirênio de Almeida

    2012-12-01

    To compare the wound healing of the abdominal wall of rabbits exposed to nicotine and submitted to abdominoplasty using 2-octyl cyanoacrylate or nylon thread for the surgery suture. Thirty two rabbits were used. They were divided in subgroups: A1, A2, B1 e B2. Group A received saline 0.9%; group B received nicotine, both groups for 14 days before surgery. We performed an abdominoplasty with a nylon suture into the A1 and B1 subgroups; as for A2 and B2 groups the suture was performed with cyanoacrylate. The euthanasia happened in the 14th post-operative day. After, we evaluated: swollen process, fibroblast proliferation, collagen, neovascularization, and macroscope and microscope epithelization of the scars. We observed the presence of eosinophils in all scars exposed to the cyanoacrylate, and a significant increase of neovascularization in the subgroup B2 comparing to the A2 one (p=0.037). The other variables haven't showed any statistical difference. Nicotine hasn't influenced the swollen process, the fibroblast proliferation, the presence of collagen, neither the epithelialization. The neovascularization showed cicatricial immaturity when comparing group A2 to group B2. The eosinophils in the scars repaired with glue showed that the substance has acted as an allergen.

  7. (5-n-Butyl-10,20-diiso­butyl­porphyrin­ato)nickel(II)

    PubMed Central

    Senge, Mathias O.; Dahms, Katja

    2014-01-01

    The asymmetric unit of the title compound, [Ni(C32H36N4)], contains two independent mol­ecules exhibiting an overall ruffled conformation of the porphyrin macrocycle and differing mainly in the positions of the methyl groups. The average Ni—N bond lengths are 1.912 (2) and 1.910 (2) Å in the two mol­ecules. The mol­ecules form a closely spaced lattice structure in which neighbouring porphyrins are oriented in a nearly perpendicular fashion to each other. The compound was prepared via nucleophilic substitution of (5,15-diiso­butyl­porphyrinato)nickel(II) with n-butyl­lithium. PMID:25161518

  8. Endovascular treatment of isolated systemic arterial supply to normal lung with coil and glue embolisation

    PubMed Central

    Anil, G; Taneja, M; Tan, A-G-S

    2012-01-01

    Surgery is the standard treatment for the extremely rare pathology of isolated anomalous systemic arterial supply to normal lung (ISSNL). We describe our experience with this anomaly in a 29-year-old male presenting with recurrent haemoptysis that was successfully treated with a combination of metallic coils and cyanoacrylate glue. In addition to contributing to the extremely limited data on endovascular therapeutic options in ISSNL, we also intend to raise the awareness among endovascular therapists of the need to be cautious ofand preserve the radiculomedullary/pial branches arising from an anomalous artery before embolising it. PMID:22457413

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samuelson, Shaun D.; Louie, John D.; Sze, Daniel Y., E-mail: dansze@stanford.edu

    Purpose. Avoidance of nontarget microsphere deposition via hepatoenteric anastomoses is essential to the safety of yttrium-90 radioembolization (RE). The hepatic hilar arterial network may remain partially patent after coil embolization of major arteries, resulting in persistent risk. We retrospectively reviewed cases where n-butyl cyanoacrylate (n-BCA) glue embolization was used to facilitate endovascular hepatic arterial skeletonization before RE. Methods. A total of 543 RE procedures performed between June 2004 and March 2012 were reviewed, and 10 were identified where n-BCA was used to embolize hepatoenteric anastomoses. Arterial anatomy, prior coil embolization, and technical details were recorded. Outcomes were reviewed to identifymore » subsequent complications of n-BCA embolization or nontarget RE. Results. The rate of complete technical success was 80 % and partial success 20 %, with one nontarget embolization complication resulting in a minor change in treatment plan. No evidence of gastrointestinal or biliary ischemia or infarction was identified, and no microsphere-related gastroduodenal ulcerations or other evidence of nontarget RE were seen. Median volume of n-BCA used was <0.1 ml. Conclusion. n-BCA glue embolization is useful to eliminate hepatoenteric networks that may result in nontarget RE, especially in those that persist after coil embolization of major vessels such as the gastroduodenal and right gastric arteries.« less

  10. Evaluation of one-step luminescent cyanoacrylate fuming.

    PubMed

    Khuu, Alicia; Chadwick, Scott; Spindler, Xanthe; Lam, Rolanda; Moret, Sébastien; Roux, Claude

    2016-06-01

    One-step luminescent cyanoacrylates have recently been introduced as an alternative to the conventional cyanoacrylate fuming methods. These new techniques do not require the application of a luminescent post-treatment in order to enhance cyanoacrylate-developed fingermarks. In this study, three one-step polymer cyanoacrylates: CN Yellow Crystals (Aneval Inc.), PolyCyano UV (Foster+Freeman Ltd.) and PECA Multiband (BVDA), and one monomer cyanoacrylate: Lumikit™ (Crime Scene Technology), were evaluated against a conventional two-step cyanoacrylate fuming method (Cyanobloom (Foster+Freeman Ltd.) with rhodamine 6G stain). The manufacturers' recommended conditions or conditions compatible with the MVC™ 1000/D (Foster+Freeman Ltd.) were assessed with fingermarks aged for up to 8 weeks on non-porous and semi-porous substrates. Under white light, Cyanobloom generally gave better development than the one-step treatments across the substrates. Similarly when viewed under the respective luminescent conditions, Cyanobloom with rhodamine 6G stain resulted in improved contrast against the one-step treatments except on polystyrene, where PolyCyano UV and PECA Multiband gave better visualisation. Rhodamine 6G post-treatment of one-step samples did not significantly enhance the contrast of any of the one-step treatments against Cyanobloom/rhodamine 6G-treated samples. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Pelvic arteriovenous malformation treated by transarterial glue embolisation combining proximal balloon occlusion and devascularisation of multiple feeding arteries.

    PubMed

    Murakami, Kenji; Yamada, Takayuki; Kumano, Reiko; Nakajima, Yasuo

    2014-06-06

    We present a case of a 70-year-old man with abdominal aortic aneurysm and coincident pelvic arteriovenous malformation (AVM). Before the operation for the aneurysm, we embolised the pelvic AVM that had multiple feeding arteries and an aneurysmal-dilated draining vein. After decreasing the number of the feeding arteries by coil embolisation, an n-butyl-2-cyanoacrylate/lipiodol mixture (1:1) was injected into the prominent feeding artery and nidus with proximal balloon occlusion of the right internal iliac artery to decrease the flow to the nidus. The mixture (1:4-8) was also added for the finer feeding arteries that became apparent after the initial procedure to embolise the rest of the nidus. A follow-up study showed no contrast enhancement of the nidus and aneurysmal draining vein. 2014 BMJ Publishing Group Ltd.

  12. Serum aluminium levels in glue-sniffer adolescent and in glue containers.

    PubMed

    Akay, Cemal; Kalman, Süleyman; Dündaröz, Ruşen; Sayal, Ahmet; Aydin, Ahmet; Ozkan, Yalçin; Gül, Hüsamettin

    2008-05-01

    Glue sniffing is a serious medical problem among teenagers. Various chemical substances such as toluene and benzene containing glues have been reported to be toxic. It has been demonstrated that some toxic metals such as lead are elevated in the blood of solvent-addicted patients. Whereas aluminium is an element that has toxic effects on neurological, hematopoetic system and bone metabolism. We want to determine the serum levels of aluminium in glue-sniffer adolescents in comparison with healthy subjects. In addition, we compared aluminium levels of different commercial glue preparations (i.e. metal and plastic containers), to determine which type of container is better for less aluminium toxicity. We measured serum levels of aluminium in 37 glue-sniffer and 37 healthy subjects using atomic absorption spectrophotometry. The average duration of glue-sniffer was 3.8 +/- 0.8 years. We also measured aluminium levels of 10 commercial glue preparations that seven of them with metal and three with plastic containers. We found that serum levels of aluminium were 63.29 +/- 13.20 ng/ml and 36.7 +/- 8.60 ng/ml in glue-sniffer and in control subjects, respectively (P < 0.001). The average aluminium level in the glues was 8.6 +/- 3.24 ng/g in the preparations with metal containers, whereas 3.03 +/- 0.76 ng/g with plastic containers (P < 0.001). Therefore, to decrease the incidence of aluminium toxicity in glue-sniffers, it may be a good step to market of glue preparations in plastic instead of metal containers.

  13. The detection of drugs of abuse in fingerprints using Raman spectroscopy II: cyanoacrylate-fumed fingerprints

    NASA Astrophysics Data System (ADS)

    Day, Joanna S.; Edwards, Howell G. M.; Dobrowski, Steven A.; Voice, Alison M.

    2004-07-01

    This paper describes the application of Raman spectroscopy to the detection of exogenous substances in cyanoacrylate-fumed fingerprints. The scenario considered was that of an individual handling a substance and subsequently depositing a contaminated fingerprint. These fingerprints were enhanced by cyanoacrylate fuming, a process in which a layer of white cyanoacrylate polymer is deposited on the fingerprint material, enabling visual detection. Five drugs of abuse (codeine phosphate, cocaine hydrochloride, amphetamine sulphate, barbital and nitrazepam) and five non-controlled substances of similar appearance, which may be used in the adulteration of drugs of abuse (caffeine, aspirin, paracetamol, starch and talc), were used. The substances studied could be clearly distinguished using their Raman spectra and were all successfully detected in cyanoacrylate-fumed fingerprints. Photobleaching was necessary to reduce the fluorescence background in the spectra of some substances. Raman spectra obtained from the substances in cyanoacrylate-fumed fingerprints were of a similar quality to spectra obtained from the substances under normal sampling conditions, however, interfering Raman bands arising from the cyanoacrylate polymer were present in the spectra. In most cases the only interfering band was the CN stretching mode of the polymer, and there were no cases where the interfering bands prevented identification of the substances. If necessary, the interfering bands could be successfully removed by spectral subtraction. The most difficult aspect of the detection of these substances in cyanoacrylate-fumed fingerprints was visually locating the substance in the fingerprint beneath the polymer layer in order to obtain a Raman spectrum.

  14. Final report of the addendum to the safety assessment of n-butyl alcohol as used in cosmetics.

    PubMed

    McLain, Valerie C

    2008-01-01

    n-Butyl Alcohol is a primary aliphatic alcohol historically used as a solvent in nail care cosmetic products, but new concentration of use data indicate that it also is being used at low concentrations in eye makeup, personal hygiene, and shaving cosmetic products. n-Butyl Alcohol has been generally recognized as safe for use as a flavoring substance in food and appears on the 1982 Food and Drug Administration (FDA) list of inactive ingredients for approved prescription drug products. n-Butyl Alcohol can be absorbed through the skin, lungs, and gastrointestinal tract. n-Butyl Alcohol may be formed by hydrolysis of butyl acetate in the blood, but is rapidly oxidized. The single oral dose LD(50) of n-Butyl Alcohol for rats was 0.79 to 4.36 g/kg. The dermal LD(50) for rabbits was 4.2 g/kg. Inhalation toxicity studies in humans demonstrate sensory irritation of the upper respiratory tract, but only at levels above 3000 mg/m(3). Animal studies demonstrate intoxication, restlessness, ataxia, prostration, and narcosis. Exposures of rats to levels up to 4000 ppm failed to produce hearing defects. High concentrations of n-Butyl Alcohol vapors can be fatal. Ocular irritation was observed for n-Butyl alcohol at 0.005 ml of a 40% solution. The behavioral no-effect dose for n-Butyl Alcohol injected subcutaneously (s.c.) was 120 mg/kg. Fetotoxicity has been demonstrated, but only at maternally toxic levels (1000 mg/kg). No significant behavioral or neurochemical effects were seen in offspring following either maternal or paternal exposure to 3000 or 6000 ppm. n-Butyl Alcohol was not mutagenic in Ames tests, did not induce sister-chromatid exchange or chromosome breakage in chick embryos or Chinese hamster ovary cells, did not induce micronuclei formation in V79 Chinese hamster cells, did not have any chromosome-damaging effects in a mouse micronucleus test, and did not impair chromosome distribution in the course of mitosis. Clinical testing of n-Butyl Alcohol for

  15. Zwitterionic Nanofibers of Super-Glue for Transparent and Biocompatible Multi-Purpose Coatings

    NASA Astrophysics Data System (ADS)

    Mele, Elisa; Heredia-Guerrero, José A.; Bayer, Ilker S.; Ciofani, Gianni; Genchi, Giada G.; Ceseracciu, Luca; Davis, Alexander; Papadopoulou, Evie L.; Barthel, Markus J.; Marini, Lara; Ruffilli, Roberta; Athanassiou, Athanassia

    2015-09-01

    Here we show that macrozwitterions of poly(ethyl 2-cyanoacrylate), commonly called Super Glue, can easily assemble into long and well defined fibers by electrospinning. The resulting fibrous networks are thermally treated on glass in order to create transparent coatings whose superficial morphology recalls the organization of the initial electrospun mats. These textured coatings are characterized by low liquid adhesion and anti-staining performance. Furthermore, the low friction coefficient and excellent scratch resistance make them attractive as solid lubricants. The inherent texture of the coatings positively affects their biocompatibility. In fact, they are able to promote the proliferation and differentiation of myoblast stem cells. Optically-transparent and biocompatible coatings that simultaneously possess characteristics of low water contact angle hysteresis, low friction and mechanical robustness can find application in a wide range of technological sectors, from the construction and automotive industries to electronic and biomedical devices.

  16. Zwitterionic Nanofibers of Super-Glue for Transparent and Biocompatible Multi-Purpose Coatings

    PubMed Central

    Mele, Elisa; Heredia-Guerrero, José A.; Bayer, Ilker S.; Ciofani, Gianni; Genchi, Giada G.; Ceseracciu, Luca; Davis, Alexander; Papadopoulou, Evie L.; Barthel, Markus J.; Marini, Lara; Ruffilli, Roberta; Athanassiou, Athanassia

    2015-01-01

    Here we show that macrozwitterions of poly(ethyl 2-cyanoacrylate), commonly called Super Glue, can easily assemble into long and well defined fibers by electrospinning. The resulting fibrous networks are thermally treated on glass in order to create transparent coatings whose superficial morphology recalls the organization of the initial electrospun mats. These textured coatings are characterized by low liquid adhesion and anti-staining performance. Furthermore, the low friction coefficient and excellent scratch resistance make them attractive as solid lubricants. The inherent texture of the coatings positively affects their biocompatibility. In fact, they are able to promote the proliferation and differentiation of myoblast stem cells. Optically-transparent and biocompatible coatings that simultaneously possess characteristics of low water contact angle hysteresis, low friction and mechanical robustness can find application in a wide range of technological sectors, from the construction and automotive industries to electronic and biomedical devices. PMID:26357936

  17. Derivation of a human equivalent concentration for n-butanol using a physiologically based pharmacokinetic model for n-butyl acetate and metabolites n-butanol and n-butyric acid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teeguarden, Justin G.; Deisinger, P. J.; Poet, Torka S.

    2005-05-01

    The metabolic series (family) approach for risk assessment uses a dosimetry-based analysis to develop toxicity information for a group of metabolically linked compounds using pharmacokinetic (PK) data for each compound and toxicity data for the parent compound. An initial physiologically-based pharmacokinetic (PBPK) model was developed to support the implementation of the metabolic series approach for n-butyl acetate and its subsequent metabolites, n-butanol, and n-butyric acid (the butyl series) (Barton et al. 2000). In conjunction with pilot pharmacokinetic studies, the model was used to design the definitive intravenous (i.v.) PK studies. Rats were implanted with dual indwelling cannulae and administered testmore » compounds by i.v. bolus dose, i.v. infusion, or by inhalation in a recirculating closed chamber. Hepatic, vascular and extravascular metabolic constants for metabolism were estimated by fitting the model to the blood time course data from these experiments. The respiratory bioavailability of n-butyl acetate and n-butanol was estimated from closed chamber inhalation studies and measured ventilation rates. The resulting butyl series PBPK model successfully reproduces the blood time course of these compounds following i.v. administration, and inhalation exposure to n-butyl acetate and n-butanol. A fully scaled human version of the model successfully reproduces arterial blood n-butanol kinetics following inhalation exposure to n-butanol. These validated i.v (rat) and inhalation route models (rat, butyl acetate, n-butanol; human, butanol only) can be used to support species and dose-route extrapolations required for risk assessment of butyl series family of compounds. Further, this work demonstrates the usefulness of i.v. kinetic data for parameterization of systemic metabolism and the value of collaboration between experimentalists and kineticists in the development of PBPK models. The product of this effort, validated rat and human PBPK models for the

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mandapaka, A; Ghebremedhin, A; Patyal, B

    Purpose: To validate the treatment planning system predicted proton dose beyond a heterogeneity (n-BCA glue) by making a measurement in a custom acrylic phantom. Methods: A custom cubic acrylic phantom was designed for this experiment. A container was designed to fit in the phantom. This container was filled with TRUFILL™ n-Butyl Cyanoacrylate(n-BCA) glue. When the container was placed in the phantom, its center was at a distance of 7.4cm from the entrance. This depth allows us to make measurements around the center of modulation of a 126 MeV proton beam with a 3cm spread-out-Bragg peak. To make measurements at othermore » beam energies, additional acrylic can be added in front of the phantom, to adjust the depth of the heterogeneity. A diamond detector was cross calibrated against a standard cylindrical ion chamber in a 126MeV beam. The diamond detector was then used to make dose measurements beyond the inhomogeneity. The measurement was repeated with the container filled with water. Several measurements were made at each setup, to check reproducibility of measurements. Results: For the same number of Tic3R1 counts, the dose measured with the diamond detector beyond n-BCA glue was 1.053 times the dose measured beyond the water filled container. This result is in agreement with the measured stopping power of glue (1.06). These measurements were in agreement with the dose predicted by the treatment planning system when the electron density of the heterogeneity was replaced with 1.06 before the dose calculation. Conclusion: Our initial measurements validate the dose predicted by our treatment plan in the presence of heterogeneity in a phantom. The material tested (n-BCA glue) is commonly used in the treatment of AVM’s prior to an SRS treatment. An error in dose predicted by the treatment plan in the presence of the glue can be detrimental in a single fraction high dose SRS treatment I received the n-BCA liquid embolic system samples from Codman and Shurtleff

  19. Effectiveness of glues for harmonic radar tag attachment on Halyomorpha halys (Hemiptera: Pentatomidae) and their impact on adult survivorship and mobility.

    PubMed

    Lee, Doo-Hyung; Wright, Starker E; Boiteau, Gilles; Vincent, Charles; Leskey, Tracy C

    2013-06-01

    We evaluated the effectiveness of three cyanoacrylate glues (trade names: Krazy [Elmer's Products Inc., Westerville, OH], Loctite [Henkel Corporation, Rocky Hill, CT], and FSA [Barnes Distribution, Cleveland, OH]) to attach harmonic radar tags securely on adult Halyomorpha halys (Stål) (Hemiptera: Pentatomidae) and quantified the effect of the radar tag attachment on insect survivorship and mobility. In the laboratory, the strength of the glue bond between the radar tag and H. halys pronotum was significantly increased when the pronotum was sanded to remove cuticular waxes. The adhesive bond of the radar tag to the sanded pronotum of H. halys had strength of 160-190-g force and there was no significant difference among the three types of glue tested. The three glues had no measurable effect on the survivorship of radar-tagged H. halys over 7 d, compared with untagged insects. Over a 7-d period in the laboratory, horizontal distance traveled, horizontal walking velocity, and vertical climbing distance were all unaffected by the presence of the tags regardless of glue. A field experiment was conducted to compare the free flight behavior of untagged and radar-tagged H. halys. Adults were released on a vertical dowel and their flights were tracked visually up to ≍200 m from the release point. There was no significant difference in take-off time or in flight distance, time, or speed between untagged and radar-tagged individuals. In addition, prevailing flight direction was not significantly different between untagged and radar-tagged individuals. The absence of measurable impact of the radar tag attachment on H. halys survivorship or mobility validates the use of harmonic radar tags to study the dispersal ecology of this insect in field conditions.

  20. Cyanoacrylates

    MedlinePlus

    Wash exposed areas with warm water right away. If the glue gets on the eyelids, try to keep the eyelids separated. If the eye becomes glued shut, get emergency medical care right away. If the eye is partially ...

  1. A comparison between atmospheric/humidity and vacuum cyanoacrylate fuming of latent fingermarks.

    PubMed

    Farrugia, Kevin J; Fraser, Joanna; Friel, Lauren; Adams, Duncan; Attard-Montalto, Nicola; Deacon, Paul

    2015-12-01

    A number of pseudo-operational trials were set up to compare the atmospheric/humidity and vacuum cyanoacrylate fuming processes on plastic carrier bags. The fuming processes were compared using two-step cyanoacrylate fuming with basic yellow 40 (BY40) staining and a one-step fluorescent cyanoacrylate fuming, Lumicyano 4%. Preliminary work using planted fingermarks and split depletions were performed to identify the optimum vacuum fuming conditions. The first pseudo-operational trial compared the different fuming conditions (atmospheric/humidity vs. vacuum) for the two-step process where an additional 50% more marks were detected with the atmospheric/humidity process. None of the marks by the vacuum process could be observed visually; however, a significant number of marks were detected by fluorescence after BY40 staining. The second trial repeated the same work in trial 1 using the one-step cyanoacrylate process, Lumicyano at a concentration of 4%. Trial 2 provided comparable results to trial 1 and all the items were then re-treated with Lumicyano 4% at atmospheric/humidity conditions before dyeing with BY40 to provide the sequences of process A (Lumicyano 4% atmospheric-Lumicyano 4% atmospheric-BY40) and process B (Lumicyano 4% vacuum-Lumicyano 4% atmospheric-BY40). The number of marks (visual and fluorescent) was counted after each treatment with a substantial increase in the number of detected marks in the second and third treatments of the process. The increased detection rate after the double Lumicyano process was unexpected and may have important implications. Trial 3 was performed to investigate whether the amount of cyanoacrylate and/or fuming time had an impact on the results observed in trial 2 whereas trial 4 assessed if the double process using conventional cyanoacrylate, rather than Lumicyano 4%, provided an increased detection rate. Trials 3 and 4 confirmed that doubling the amount of Lumicyano 4% cyanoacrylate and fuming time produced a lower

  2. A PHYSIOLOGICALLY-BASED PHARMACOKINETIC MODEL FOR INTRAVENOUS AND INHALATION-ROUTE PHARMACOKINETICS OF BUTYL ACETATE AND METABOLITES N-BUTANOL AND N-BUTYRIC ACID

    EPA Science Inventory

    Risk assessment for n-butyl acetate and metabolites n-butanol and n-butyric acid (the butyl series) can be accomplished with limited toxicity data and pharmacokinetic data for each compound through application of the "family approach" (Barton et al., 2000). The necessary quantita...

  3. Fibrin glue.

    PubMed

    Brennan, M

    1991-12-01

    Fibrin glue is a topical biological adhesive, the effect of which imitates the final stages of coagulation. The glue consists of a solution of concentrated human fibrinogen which is activated by the addition of bovine thrombin and calcium chloride. The resultant clot aids haemostasis and tissue sealing and is completely absorbed during wound healing without foreign body reaction or extensive fibrosis. The fibrinogen component of fibrin glue can be produced from fresh frozen plasma obtained from single unit donations thereby reducing the risks of transfusion transmitted infections encountered by exposure to pools from large numbers of donors. Methods involving precipitation of fibrinogen by cryoprecipitation, polyethylene glycol or ammonium sulphate have been described and evaluated. The risk of transmission of infection can be further reduced by using plasma from 'accredited donors' who are plasma donors regularly tested for ALT and markers of viral infection or by use of fibrinogen prepared in advance of surgery from autologous blood. The second component, a mixture of thrombin and CaCl2, is quantitatively and qualitatively well defined and commercially available (Armour Pharmaceutical Co., Thrombinar (bovine thrombin]. Thrombin is applied to the operation site simultaneously and in equal volume to the fibrinogen but from a separate syringe. In the UK a commercial heat treated fibrin glue prepared from pooled plasma is available on a doctor/named patient basis (Tisseel, Immuno, Vienna). The haemostatic and adhesive properties of fibrin glue can be employed in virtually every surgical specialty. The usefulness of the glue is particularly well documented in the fields of cardiovascular surgery, ENT and neurosurgery.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Bonding strength of alkyl-2-cyanoacrylates to bone in vitro.

    PubMed

    Kilpikari, J; Lapinsuo, M; Törmälä, P; Pätiälä, H; Rokkanen, P

    1986-10-01

    This study measured the bonding strength between alkyl-2-cyanoacrylates and bone, and examined how treatment of the bone surface with acid, and prolonged exposure to moisture, affected this strength. The initial strength of all cyanoacrylates was high (9.6-11.2 N/mm2). In long-term experiments under water, n- and i-butylcyanoacrylates lost their strength at a far slower rate than ethylcyanoacrylates. However, the butylcyanoacrylates also showed a decrease of 15% in strength after three weeks. Pretreatment of the bone surface with acid did not have a marked effect on bonding strength, although SEM investigation revealed that the acid treatment had increased the porosity of the bone surface. A study of the fracture surface proved that the adhesive film tended to loosen or break after 3 to 6 weeks under water. The decrease in the bonding strength was probably due to the degradation of the adhesive film in water which loosened mechanical bonds between the bone and adhesive. Considering clinical use it would be necessary to achieve better long-term strength.

  5. Reactivities of Substituted α-Phenyl-N-tert-butyl Nitrones

    PubMed Central

    2015-01-01

    In this work, a series of α-phenyl-N-tert-butyl nitrones bearing one, two, or three substituents on the tert-butyl group was synthesized. Cyclic voltammetry (CV) was used to investigate their electrochemical properties and showed a more pronounced substituent effect for oxidation than for reduction. Rate constants of superoxide radical (O2•–) reactions with nitrones were determined using a UV–vis stopped-flow method, and phenyl radical (Ph•) trapping rate constants were measured by EPR spectroscopy. The effect of N-tert-butyl substitution on the charge density and electron density localization of the nitronyl carbon as well as on the free energies of nitrone reactivity with O2•– and HO2• were computationally rationalized at the PCM/B3LYP/6-31+G**//B3LYP/6-31G* level of theory. Theoretical and experimental data showed that the rates of the reaction correlate with the nitronyl carbon charge density, suggesting a nucleophilic nature of O2•– and Ph• addition to the nitronyl carbon atom. Finally, the substituent effect was investigated in cell cultures exposed to hydrogen peroxide and a correlation between the cell viability and the oxidation potential of the nitrones was observed. Through a combination of computational methodologies and experimental methods, new insights into the reactivity of free radicals with nitrone derivatives have been proposed. PMID:24968285

  6. 21 CFR 520.260 - n-Butyl chloride capsules.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... require 3 or 4 doses at 10-day intervals. (c) Puppies, dogs, cats, or kittens weighing 1 to 3 pounds... of n-butyl chloride in each capsule. (2) Sponsor. See No. 021091 in § 510.600(c) of this chapter. (3... ascarid (Toxocara cati) and hookworm (Ancylostoma tubaeforme) from cats. (ii)(a) Animals should not be fed...

  7. 40 CFR 721.10193 - 1-Butanaminium, N-(3-aminopropyl)-N-butyl-N-(2-carboxyethyl)-, N-coco acyl derivs., inner salts.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false 1-Butanaminium, N-(3-aminopropyl)-N-butyl-N-(2-carboxyethyl)-, N-coco acyl derivs., inner salts. 721.10193 Section 721.10193 Protection of... CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.10193 1-Butanaminium, N-(3...

  8. Prospective study of bacteremia rate after elective band ligation and sclerotherapy with cyanoacrylate for esophageal varices in patients with advanced liver disease.

    PubMed

    Bonilha, Danielle Queiroz; Correia, Lucianna Motta; Monaghan, Marie; Lenz, Luciano; Santos, Marcus; Libera, Ermelindo Della

    2011-01-01

    Band ligation (BL) is the most appropriate endoscopic treatment for acute bleeding or prophylaxis of esophageal variceal bleeding. Sclerotherapy with N-butyl-2-cyanoacrylate (CY) can be an alternative for patients with advanced liver disease. Bacteremia is an infrequent complication after BL while the bacteremia rate following treatment with CY for esophageal varices remains unknown. To evaluate and compare the incidence of transient bacteremia between cirrhotic patients submitted to diagnostic endoscopy, CY and BL for treatment of esophageal varices. A prospective study comprising the period from 2004 to 2007 was conducted at Hospital of Universidade Federal de São Paulo, UNIFESP, SP, Brazil. Cirrhotic patients with advanced liver disease (Child-Pugh B or C) were enrolled. The patients were divided into two groups according treatment: BL Group (patients undergoing band ligation, n = 20) and CY Group (patients receiving cyanoacrylate injection for esophageal variceal, n = 18). Cirrhotic patients with no esophageal varices or without indication for endoscopic treatment were recruited as control (diagnostic group n = 20). Bacteremia was evaluated by blood culture at baseline and 30 minutes after the procedure. After 137 scheduled endoscopic procedures, none of the 58 patients had fever or any sign suggestive of infection. All baseline cultures were negative. No positive cultures were observed after CY or in the control group - diagnostic endoscopy. Three (4.6 %) positive cultures were found out of the 65 sessions of band ligation (P = 0.187). Two of these samples were positive for coagulase-negative staphylococcus, which could be regarded as a contaminant. The isolated microorganism in the other case was Klebsiella oxytoca. The patient in this case presented no evidence of immunodeficiency except liver disease. There was no significant difference in bacteremia rate between these three groups. BL or CY injection for non-bleeding esophageal varices may be considered

  9. N-tert-Butyl-N'-(5,7-dimethyl-1,8-naphthyridin-2-yl)urea.

    PubMed

    Lüning, U; Kühl, C; Bolte, M

    2001-08-01

    The title compound, C(15)H(20)N(4)O, has been synthesized as an AADD recognition unit for quadruple hydrogen bonds. All non-H atoms of the molecule apart from two methyl groups of the tert-butyl group lie in a common plane. An intramolecular hydrogen bond is formed connecting two N atoms. In the solid state, the title compound crystallizes as a centrosymmetric dimer connected by N-H...O=C interactions with an N...O distance of 2.824 (2) A.

  10. The Millimeterwave Spectrum of n-BUTYL Cyanide

    NASA Astrophysics Data System (ADS)

    Ordu, Matthias H.; Müller, Holger S. P.; Lewen, Frank; Schlemmer, Stephan; Nez, Marc Nu; Walters, Adam

    2011-06-01

    The rotational spectrum of n-butyl cyanide (C_4H_9CN) was measured between 75 and 130 GHz using a novel all-solid-state spectrometer with a total absorption path of 44 m. In the course of the analysis of the spectrum, about 3000 transitions were assigned and a full set of quartic centrifugal distortion parameters with some sextic and octic terms could be determined for each of the three known conformers (anti-anti, anti-gauche(methyl end) and gauche(CN end)-anti). The work was motivated by the fact that n-butyl cyanide is likely to be found in interstellar hot core environments. This is indicated by the discovery of n-propyl cyanide (C_3H_7CN), the next smaller alkyl cyanide, in the ISM. The increased accuracy of the model, which will be additionally extended by future laboratory measurements around 200 GHz, may now be employed for a prediction of the spectrum up to 300 GHz with a feasible uncertainty for astronomic line surveys. Furthermore, there are two less abundant conformers, cis-gauche-gauche and trans-gauche-gauche, which have not yet been detected in the rotational spectrum. Due to the increased sensitivity of the new spectrometer, it seems possible now for the first time to identify their sectroscopic fingerprints in the recorded data. A. Belloche, R. T. Garrod, H. S. P.Müller, K. M. Menten, C. Comito, and P. Schilke, Astronomy & Astrophysics 499, 215 (2009) R. K. Bohn, J. L. Pardus, J. August, T. Brupbacher, W. Jäger, J. Mol. Struct. 413-414, 293 (1997)

  11. Use of cyanoacrylate in the coaptation of edges of surgical wounds*

    PubMed Central

    Lins, Ruthinéia Diógenes Alves Uchôa; Gomes, Raquel Christina Barboza; dos Santos, Kátia Simone Alves; da Silva, Paula Vanessa; da Silva, Renata Torres Moreira; Ramos, Ianny Alves

    2012-01-01

    Cyanoacrylate has been used in several fields of different surgical specialties as an adhesive for closure of gingival flaps and in mucous and cutaneous lacerations. One of its advantages is that it has an excellent immunological response. In view of aesthetic needs, cyanoacrylate has been applied with satisfactory results, when compared with sutures. It presents better coaptation of edges of cutaneous and mucosal lesions, smaller residual scars, and biocompatibility. However, it is limited to areas of little tissue tension. This work attempts to provide a literature review with the aim of revealing the advantages of using tissue adhesives, especially cyanoacrylates, in wound coaptation in comparison with conventional methods. PMID:23197206

  12. 21 CFR 178.3120 - Animal glue.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Animal glue. 178.3120 Section 178.3120 Food and... Animal glue. Animal glue may be safely used as a component of articles intended for use in producing... the provisions of this section. (a) Animal glue consists of the proteinaceous extractives obtained...

  13. The GlueX DIRC detector

    NASA Astrophysics Data System (ADS)

    Barbosa, F.; Bessuille, J.; Chudakov, E.; Dzhygadlo, R.; Fanelli, C.; Frye, J.; Hardin, J.; Kelsey, J.; Patsyuk, M.; Schwarz, C.; Schwiening, J.; Stevens, J.; Shepherd, M.; Whitlatch, T.; Williams, M.

    2017-12-01

    The GlueX DIRC (Detection of Internally Reflected Cherenkov light) detector is being developed to upgrade the particle identification capabilities in the forward region of the GlueX experiment at Jefferson Lab. The GlueX DIRC will utilize four existing decommissioned BaBar DIRC bar boxes, which will be oriented to form a plane roughly 4 m away from the fixed target of the experiment. A new photon camera has been designed that is based on the SuperB FDIRC prototype. The full GlueX DIRC system will consist of two such cameras, with the first planned to be built and installed in 2017. We present the current status of the design and R&D, along with the future plans of the GlueX DIRC detector.

  14. Mounting ground sections of teeth: Cyanoacrylate adhesive versus Canada balsam.

    PubMed

    Vangala, Manogna Rl; Rudraraju, Amrutha; Subramanyam, R V

    2016-01-01

    Hard tissues can be studied by either decalcification or by preparing ground sections. Various mounting media have been tried and used for ground sections of teeth. However, there are very few studies on the use of cyanoacrylate adhesive as a mounting medium. The aim of our study was to evaluate the efficacy of cyanoacrylate adhesive (Fevikwik™) as a mounting medium for ground sections of teeth and to compare these ground sections with those mounted with Canada balsam. Ground sections were prepared from twenty extracted teeth. Each section was divided into two halves and mounted on one slide, one with cyanoacrylate adhesive (Fevikwik™) and the other with Canada balsam. Scoring for various features in the ground sections was done by two independent observers. Statistical analysis using Student's t-test (unpaired) of average scores was performed for each feature observed. No statistically significant difference was found between the two for most of the features. However, cyanoacrylate was found to be better than Canada balsam for observing striae of Retzius (P < 0.0205), enamel lamellae (P < 0.036), dentinal tubules (P < 0.0057), interglobular dentin (P < 0.0001), sclerotic dentin - transmitted light (P < 0.00001), sclerotic dentin - polarized light (P < 0.0002) and Sharpey's fibers (P < 0.0004). This initial study shows that cyanoacrylate is better than Canada balsam for observing certain features of ground sections of teeth. However, it remains to be seen whether it will be useful for studying undecalcified sections of carious teeth and for soft tissue sections.

  15. Mounting ground sections of teeth: Cyanoacrylate adhesive versus Canada balsam

    PubMed Central

    Vangala, Manogna RL; Rudraraju, Amrutha; Subramanyam, RV

    2016-01-01

    Introduction: Hard tissues can be studied by either decalcification or by preparing ground sections. Various mounting media have been tried and used for ground sections of teeth. However, there are very few studies on the use of cyanoacrylate adhesive as a mounting medium. Aims: The aim of our study was to evaluate the efficacy of cyanoacrylate adhesive (Fevikwik™) as a mounting medium for ground sections of teeth and to compare these ground sections with those mounted with Canada balsam. Materials and Methods: Ground sections were prepared from twenty extracted teeth. Each section was divided into two halves and mounted on one slide, one with cyanoacrylate adhesive (Fevikwik™) and the other with Canada balsam. Scoring for various features in the ground sections was done by two independent observers. Statistical Analysis Used: Statistical analysis using Student's t-test (unpaired) of average scores was performed for each feature observed. Results: No statistically significant difference was found between the two for most of the features. However, cyanoacrylate was found to be better than Canada balsam for observing striae of Retzius (P < 0.0205), enamel lamellae (P < 0.036), dentinal tubules (P < 0.0057), interglobular dentin (P < 0.0001), sclerotic dentin – transmitted light (P < 0.00001), sclerotic dentin – polarized light (P < 0.0002) and Sharpey's fibers (P < 0.0004). Conclusions: This initial study shows that cyanoacrylate is better than Canada balsam for observing certain features of ground sections of teeth. However, it remains to be seen whether it will be useful for studying undecalcified sections of carious teeth and for soft tissue sections. PMID:27194857

  16. 21 CFR 178.3120 - Animal glue.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Animal glue. 178.3120 Section 178.3120 Food and... and Production Aids § 178.3120 Animal glue. Animal glue may be safely used as a component of articles..., transporting, or holding food, subject to the provisions of this section. (a) Animal glue consists of the...

  17. 21 CFR 178.3120 - Animal glue.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Animal glue. 178.3120 Section 178.3120 Food and... and Production Aids § 178.3120 Animal glue. Animal glue may be safely used as a component of articles..., transporting, or holding food, subject to the provisions of this section. (a) Animal glue consists of the...

  18. 21 CFR 178.3120 - Animal glue.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Animal glue. 178.3120 Section 178.3120 Food and... and Production Aids § 178.3120 Animal glue. Animal glue may be safely used as a component of articles..., transporting, or holding food, subject to the provisions of this section. (a) Animal glue consists of the...

  19. 21 CFR 178.3120 - Animal glue.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Animal glue. 178.3120 Section 178.3120 Food and... and Production Aids § 178.3120 Animal glue. Animal glue may be safely used as a component of articles..., transporting, or holding food, subject to the provisions of this section. (a) Animal glue consists of the...

  20. Usefulness of a New Gelatin Glue Sealant System for Dural Closure in a Rat Durotomy Model

    PubMed Central

    KAWAI, Hisashi; NAKAGAWA, Ichiro; NISHIMURA, Fumihiko; MOTOYAMA, Yasushi; PARK, Young-Su; NAKAMURA, Mitsutoshi; NAKASE, Hiroyuki; SUZUKI, Shuko; IKADA, Yoshito

    2014-01-01

    Watertight dural closure is imperative after neurosurgical procedures, because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. We used a rat durotomy model to test the usefulness of a new gelatin glue as a dural sealant in a rat model of transdural CSF leakage. All rats were randomly divided into one of the following three treatment groups: no application (control group: N = 18), application of fibrin glue (fibrin glue group: N = 18), and application of the new gelatin glue (new gelatin glue group: N = 18). The craniotomy side was re-opened, and CSF leakage was checked and recorded at 1, 7, and 28 days postoperatively. The new gelatin glue was adequate for stopping CSF leakage; no leakage was observed at postoperative days 1 or 7, and leakage was observed in only one rat at postoperative day 28. This result was statistically significant when compared to the control group (P = 0.002, P = 0.015, P = 0.015, respectively). The pathologic score of the new gelatin group was not different from that of the control or fibrin glue groups. We conclude that our new gelatin glue provides effective watertight closure 1, 7, and 28 days after operation in the rat durotomy model. PMID:25070015

  1. Comparison of polyurethane with cyanoacrylate in hemostasis of vascular injury in guinea pigs.

    PubMed

    Kubrusly, Luiz Fernando; Formighieri, Marina Simões; Lago, José Vitor Martins; Graça, Yorgos Luiz Santos de Salles; Sobral, Ana Cristina Lira; Lago, Marianna Martins

    2015-01-01

    To evaluate the behavior of castor oil-derived polyurethane as a hemostatic agent and tissue response after abdominal aortic injury and to compare it with 2-octyl-cyanoacrylate. Twenty-four Guinea Pigs were randomly divided into three groups of eight animals (I, II, and III). The infrarenal abdominal aorta was dissected, clamped proximally and distally to the vascular puncture site. In group I (control), hemostasis was achieved with digital pressure; in group II (polyurethane) castor oil-derived polyurethane was applied, and in group III (cyanoacrylate), 2-octyl-cyanoacrylate was used. Group II was subdivided into IIA and IIB according to the time of preparation of the hemostatic agent. Mean blood loss in groups IIA, IIB and III was 0.002 grams (g), 0.008 g, and 0.170 g, with standard deviation of 0.005 g, 0.005 g, and 0.424 g, respectively (P=0.069). The drying time for cyanoacrylate averaged 81.5 seconds (s) (standard deviation: 51.5 seconds) and 126.1 s (standard deviation: 23.0 s) for polyurethane B (P=0.046). However, there was a trend (P=0.069) for cyanoacrylate to dry more slowly than polyurethane A (mean: 40.5 s; SD: 8.6 s). Furthermore, polyurethane A had a shorter drying time than polyurethane B (P=0.003), mean IIA of 40.5 s (standard deviation: 8.6 s). In group III, 100% of the animals had mild/severe fibrosis, while in group II only 12.5% showed this degree of fibrosis (P=0.001). Polyurethane derived from castor oil showed similar hemostatic behavior to octyl-2-cyanoacrylate. There was less perivascular tissue response with polyurethane when compared with cyanoacrylate.

  2. Surgical adhesives in ophthalmology: history and current trends.

    PubMed

    Guhan, Samantha; Peng, Si-Liang; Janbatian, Hrag; Saadeh, Stephanie; Greenstein, Stephen; Al Bahrani, Faisal; Fadlallah, Ali; Yeh, Tsai-Chu; Melki, Samir A

    2018-03-26

    Tissue adhesives are gaining popularity in ophthalmology, as they could potentially reduce the complications associated with current surgical methods. An ideal tissue adhesive should have superior tensile strength, be non-toxic and anti-inflammatory, improve efficiency and be cost-effective. Both synthetic and biological glues are available. The primary synthetic glues include cyanoacrylate and the recently introduced polyethylene glycol (PEG) derivatives, while most biological glues are composed of fibrin. Cyanoacrylate has a high tensile strength, but rapidly polymerises upon contact with any fluid and has been associated with histotoxicity. Fibrin induces less toxic and inflammatory reactions, and its polymerisation time can be controlled. Tensile strength studies have shown that fibrin is not as strong as cyanoacrylate. While more research is needed, PEG variants currently appear to have the most promise. These glues are non-toxic, strong and time-effective. Through MEDLINE and internet searches, this paper presents a systematic review of the current applications of surgical adhesives to corneal, glaucoma, retinal, cataract and strabismus surgeries. Our review suggests that surgical adhesives have promise to reduce problems in current ophthalmic surgical procedures. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Subarachnoid Hemorrhage Because of Distal Superior Cerebellar Artery Dissection in Neurofibromatosis Type 1.

    PubMed

    Takeshima, Yuki; Ohmori, Yuki; Nakagawa, Takashi; Kaku, Yasuyuki; Kuratsu, Jun-Ichi; Yano, Shigetoshi

    2017-09-01

    Neurofibromatosis type 1 (NF1) is a rare disease with an incidence of 1 in every 3000 births. Numerous studies have focused on the main function of NF1 as a tumor suppressor, whereas few have examined the cerebrovascular abnormalities observed in patients with NF1. It is worth noting that intracranial aneurysms are uncommon in this condition. We report a case of NF1 with a dissection of the distal segment of the superior cerebellar artery. A 36-year-old woman presented with a distal superior cerebellar artery (SCA) dissection causing subarachnoid hemorrhage. Subsequently, because of the rich collateral blood flow distal to the dissection, N-butyl cyanoacrylate (NBCA) glue embolization was unsuccessful. Therefore, direct trapping of the artery was necessary. The patient was discharged after an uneventful postoperative period, and has remained without complications. In the treatment of subarachnoid hemorrhage because of a distal SCA dissection in patients with NF1, NBCA glue embolization may be a safer option than microsurgery or coil embolization, in the acute phase, considering the possible vulnerability of the vessel wall, accessibility, morphology of the lesions, and the risk of developing unpredictable infarcts in the case of parent artery occlusion. However, regular reevaluation of the blood flow is necessary to monitor recurrence, given the rich collateral circulation. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. The GlueX DIRC detector

    DOE PAGES

    Barbosa, F.; Bessuille, J.; Chudakov, E.; ...

    2017-02-03

    We present the GlueX DIRC (Detection of Internally Reflected Cherenkov light) detector that is being developed to upgrade the particle identification capabilities in the forward region of the GlueX experiment at Jefferson Lab. The GlueX DIRC will utilize four existing decommissioned BaBar DIRC bar boxes, which will be oriented to form a plane roughly 4 m away from the fixed target of the experiment. A new photon camera has been designed that is based on the SuperB FDIRC prototype. The full GlueX DIRC system will consist of two such cameras, with the first planned to be built and installed inmore » 2017. In addition, we present the current status of the design and R&D, along with the future plans of the GlueX DIRC detector.« less

  5. Local and systemic effects of fibrin and cyanoacrylate adhesives on lung lesions in rabbits

    PubMed Central

    Carvalho, Marcus V.H.; Marchi, Evaldo; Fruchi, Andre J.; Dias, Bruno V.B.; Pinto, Clovis L.; dos Santos, Geovane R.; Acencio, Milena M.P.

    2017-01-01

    OBJECTIVES: Tissue adhesives can be used to prevent pulmonary air leaks, which frequently occur after lung interventions. The objective of this study is to evaluate local and systemic effects of fibrin and cyanoacrylate tissue adhesives on lung lesions in rabbits. METHODS: Eighteen rabbits were submitted to videothoracoscopy + lung incision alone (control) or videothoracoscopy + lung incision + local application of fibrin or cyanoacrylate adhesive. Blood samples were collected and assessed for leukocyte, neutrophil and lymphocyte counts and interleukin-8 levels preoperatively and at 48 hours and 28 days post-operatively. After 28 days, the animals were euthanized for gross examination of the lung surface, and lung fragments were excised for histopathological analysis. RESULTS: Fibrin and cyanoacrylate produced similar adhesion scores of the lung to the parietal pleura. Microscopic analysis revealed uniform low-cellular tissue infiltration in the fibrin group and an intense tissue reaction characterized by dense inflammatory infiltration of granulocytes, giant cells and necrosis in the cyanoacrylate group. No changes were detected in the leukocyte, neutrophil or lymphocyte count at any time-point, while the interleukin-8 levels were increased in the fibrin and cyanoacrylate groups after 48 hours compared with the pre-operative control levels (p<0.01). CONCLUSION: Both adhesive agents promoted normal tissue healing, with a more pronounced local inflammatory reaction observed for cyanoacrylate. Among the serum markers of inflammation, only the interleukin-8 levels changed post-operatively, increasing after 48 hours and decreasing after 28 days to levels similar to those of the control group in both the fibrin and cyanoacrylate groups. PMID:29160425

  6. Local and systemic effects of fibrin and cyanoacrylate adhesives on lung lesions in rabbits.

    PubMed

    Carvalho, Marcus V H; Marchi, Evaldo; Fruchi, Andre J; Dias, Bruno V B; Pinto, Clovis L; Dos Santos, Geovane R; Acencio, Milena M P

    2017-10-01

    Tissue adhesives can be used to prevent pulmonary air leaks, which frequently occur after lung interventions. The objective of this study is to evaluate local and systemic effects of fibrin and cyanoacrylate tissue adhesives on lung lesions in rabbits. Eighteen rabbits were submitted to videothoracoscopy + lung incision alone (control) or videothoracoscopy + lung incision + local application of fibrin or cyanoacrylate adhesive. Blood samples were collected and assessed for leukocyte, neutrophil and lymphocyte counts and interleukin-8 levels preoperatively and at 48 hours and 28 days post-operatively. After 28 days, the animals were euthanized for gross examination of the lung surface, and lung fragments were excised for histopathological analysis. Fibrin and cyanoacrylate produced similar adhesion scores of the lung to the parietal pleura. Microscopic analysis revealed uniform low-cellular tissue infiltration in the fibrin group and an intense tissue reaction characterized by dense inflammatory infiltration of granulocytes, giant cells and necrosis in the cyanoacrylate group. No changes were detected in the leukocyte, neutrophil or lymphocyte count at any time-point, while the interleukin-8 levels were increased in the fibrin and cyanoacrylate groups after 48 hours compared with the pre-operative control levels (p<0.01). Both adhesive agents promoted normal tissue healing, with a more pronounced local inflammatory reaction observed for cyanoacrylate. Among the serum markers of inflammation, only the interleukin-8 levels changed post-operatively, increasing after 48 hours and decreasing after 28 days to levels similar to those of the control group in both the fibrin and cyanoacrylate groups.

  7. Comparison of polyurethane with cyanoacrylate in hemostasis of vascular injury in guinea pigs

    PubMed Central

    Kubrusly, Luiz Fernando; Formighieri, Marina Simões; Lago, José Vitor Martins; Graça, Yorgos Luiz Santos de Salles; Sobral, Ana Cristina Lira; Lago, Marianna Martins

    2015-01-01

    Objective To evaluate the behavior of castor oil-derived polyurethane as a hemostatic agent and tissue response after abdominal aortic injury and to compare it with 2-octyl-cyanoacrylate. Methods Twenty-four Guinea Pigs were randomly divided into three groups of eight animals (I, II, and III). The infrarenal abdominal aorta was dissected, clamped proximally and distally to the vascular puncture site. In group I (control), hemostasis was achieved with digital pressure; in group II (polyurethane) castor oil-derived polyurethane was applied, and in group III (cyanoacrylate), 2-octyl-cyanoacrylate was used. Group II was subdivided into IIA and IIB according to the time of preparation of the hemostatic agent. Results Mean blood loss in groups IIA, IIB and III was 0.002 grams (g), 0.008 g, and 0.170 g, with standard deviation of 0.005 g, 0.005 g, and 0.424 g, respectively (P=0.069). The drying time for cyanoacrylate averaged 81.5 seconds (s) (standard deviation: 51.5 seconds) and 126.1 s (standard deviation: 23.0 s) for polyurethane B (P=0.046). However, there was a trend (P=0.069) for cyanoacrylate to dry more slowly than polyurethane A (mean: 40.5 s; SD: 8.6 s). Furthermore, polyurethane A had a shorter drying time than polyurethane B (P=0.003), mean IIA of 40.5 s (standard deviation: 8.6 s). In group III, 100% of the animals had mild/severe fibrosis, while in group II only 12.5% showed this degree of fibrosis (P=0.001). Conclusion Polyurethane derived from castor oil showed similar hemostatic behavior to octyl-2-cyanoacrylate. There was less perivascular tissue response with polyurethane when compared with cyanoacrylate. PMID:25859876

  8. Glue Guns: Aiming for Safety

    ERIC Educational Resources Information Center

    Roy, Ken

    2010-01-01

    While glue guns are very useful, there are safety issues. Regardless of the temperature setting, glue guns can burn skin. The teacher should demonstrate and supervise the use of glue guns and have a plan should a student get burned. There should be an initial first aid protocol in place, followed by a visit to the school nurse. An accident report…

  9. Controlled Degradation of Poly(Ethyl Cyanoacrylate-Co-Methyl Methacrylate)(PECA-Co-PMMA) Copolymers

    USDA-ARS?s Scientific Manuscript database

    This paper describes a method for modifying poly(ethyl cyanoacrylate) in order to control the degradation and the stability as well as the glass transition temperatures. Copolymers of poly(ethyl cyanoacrylate-co-methyl methacrylate) (PECA-co-PMMA) with various compositions were synthesized by free ...

  10. n-Alkane assimilation and tert-butyl alcohol (TBA) oxidation capacity in Mycobacterium austroafricanum strains.

    PubMed

    Lopes Ferreira, Nicolas; Mathis, Hugues; Labbé, Diane; Monot, Frédéric; Greer, Charles W; Fayolle-Guichard, Françoise

    2007-06-01

    Mycobacterium austroafricanum IFP 2012, which grows on methyl tert-butyl ether (MTBE) and on tert-butyl alcohol (TBA), the main intermediate of MTBE degradation, also grows on a broad range of n-alkanes (C2 to C16). A single alkB gene copy, encoding a non-heme alkane monooxygenase, was partially amplified from the genome of this bacterium. Its expression was induced after growth on n-propane, n-hexane, n-hexadecane and on TBA but not after growth on LB. The capacity of other fast-growing mycobacteria to grow on n-alkanes (C1 to C16) and to degrade TBA after growth on n-alkanes was compared to that of M. austroafricanum IFP 2012. We studied M. austroafricanum IFP 2012 and IFP 2015 able to grow on MTBE, M. austroafricanum IFP 2173 able to grow on isooctane, Mycobacterium sp. IFP 2009 able to grow on ethyl tert-butyl ether (ETBE), M. vaccae JOB5 (M. austroaafricanum ATCC 29678) able to degrade MTBE and TBA and M. smegmatis mc2 155 with no known degradation capacity towards fuel oxygenates. The M. austroafricanum strains grew on a broad range of n-alkanes and three were able to degrade TBA after growth on propane, hexane and hexadecane. An alkB gene was partially amplified from the genome of all mycobacteria and a sequence comparison demonstrated a close relationship among the M. austroafricanum strains. This is the first report suggesting the involvement of an alkane hydroxylase in TBA oxidation, a key step during MTBE metabolism.

  11. Demethylation of 5,n-di-tert-butyl-8,n-dimethoxy[2.n]metacyclophane-1-ynes with BBr3 to afford novel [n]benzofuranophanes

    NASA Astrophysics Data System (ADS)

    Akther, Thamina; Islam, Md Monarul; Matsumoto, Taisuke; Tanaka, Junji; Feng, Xing; Redshaw, Carl; Yamato, Takehiko

    2016-10-01

    Novel [n]benzofuranophanes (n = 8 & 10) 2a-b have been prepared by successive intramolecular cyclization from 5,19-di-tert-butyl-8,22-dimethoxy[n]metacyclophane-1-yne (syn-1a-b) by treatment with BBr3 in CH2Cl2 at room temperature for 8h. [2.n]Benzofuranophanes 2a-b were also obtained by treatment of 1,2-di-endo-bromo-5,19-di-tert-butyl-8,22-dimethoxy[n]metacyclophane (meso-3a-b) with BBr3 in CH2Cl2 by using the same reaction conditions. 1H NMR spectra of 2a-b reveals the formation of intramolecular hydrogen bonding between hydroxyl proton with the oxygen of the furan moiety and X-ray analysis shows that the lengths between H (OH) and O (furan) are 1.981 and 1.823 Å̊, respectively. The conformation of [8]benzofuranophane 2a in solution is rigid with restricted rotation around the diaryl linkage rather than [10]benzofuranophane 2b because of weak intramolecular hydrogen bonding and the short length of the cross-linking chain.

  12. RATE CONSTANTS FOR THE REACTIONS OF OH RADICALS AND CL ATOMS WITH DI-N-PROPYL ETHER AND DI-N-BUTYL ETHER AND THEIR DEUTERATED ANALOGS. (R825252)

    EPA Science Inventory

    Using relative rate methods, rate constants for the gas-phase reactions of OH radicals and Cl atoms with di-n-propyl ether, di-n-propyl ether-d14, di-n-butyl ether and di-n-butyl ether-d18 have been measured at 296 ? 2 K and atmos...

  13. Bio-Source of di-n-butyl phthalate production by filamentous fungi

    NASA Astrophysics Data System (ADS)

    Tian, Congkui; Ni, Jinren; Chang, Fang; Liu, Sitong; Xu, Nan; Sun, Weiling; Xie, Yuan; Guo, Yongzhao; Ma, Yanrong; Yang, Zhenxing; Dang, Chenyuan; Huang, Yuefei; Tian, Zhexian; Wang, Yiping

    2016-02-01

    Although DBP (di-n-butyl phthalate) is commonly encountered as an artificially-synthesized plasticizer with potential to impair fertility, we confirm that it can also be biosynthesized as microbial secondary metabolites from naturally occurring filamentous fungi strains cultured either in an artificial medium or natural water. Using the excreted crude enzyme from the fungi for catalyzing a variety of substrates, we found that the fungal generation of DBP was largely through shikimic acid pathway, which was assembled by phthalic acid with butyl alcohol through esterification. The DBP production ability of the fungi was primarily influenced by fungal spore density and incubation temperature. This study indicates an important alternative natural waterborne source of DBP in addition to artificial synthesis, which implied fungal contribution must be highlighted for future source control and risk management of DBP.

  14. Processes involved in the development of latent fingerprints using the cyanoacrylate fuming method.

    PubMed

    Lewis, L A; Smithwick, R W; Devault, G L; Bolinger, B; Lewis, S A

    2001-03-01

    Chemical processes involved in the development of latent fingerprints using the cyanoacrylate fuming method have been studied. Two major types of latent prints have been investigated-clean and oily prints. Scanning electron microscopy (SEM) has been used as a tool for determining the morphology of the polymer developed separately on clean and oily prints after cyanoacrylate fuming. A correlation between the chemical composition of an aged latent fingerprint, prior to development, and the quality of a developed fingerprint has been observed in the morphology. The moisture in the print prior to fuming has been found to be more important than the moisture in the air during fuming for the development of a useful latent print. In addition, the amount of time required to develop a high quality latent print has been found to be within 2 min. The cyanoacrylate polymerization process is extremely rapid. When heat is used to accelerate the fuming process, typically a period of 2 min is required to develop the print. The optimum development time depends upon the concentration of cyanoacrylate vapors within the enclosure.

  15. 40 CFR 180.576 - Cyhalofop-butyl; tolerances for residues.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Cyhalofop-butyl; tolerances for... § 180.576 Cyhalofop-butyl; tolerances for residues. (a) General. Time-limited tolerances are established for combined residues of cyhalofop (cyhalofop-butyl, R-(+)-n-butyl-2-(4(4-cyano-2-fluorophenoxy...

  16. 40 CFR 180.576 - Cyhalofop-butyl; tolerances for residues.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Cyhalofop-butyl; tolerances for... § 180.576 Cyhalofop-butyl; tolerances for residues. (a) General. Time-limited tolerances are established for combined residues of cyhalofop (cyhalofop-butyl, R-(+)-n-butyl-2-(4(4-cyano-2-fluorophenoxy...

  17. Fabrication of self-organized conical microstructures by excimer laser irradiation of cyanoacrylate-carbon nanotube composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu Yuming; Liu Liang; Fan Shoushan

    2005-02-07

    Self-organized conical microstructures are fabricated by 308 nm XeCl excimer laser irradiation of cyanoacrylate-carbon nanotube composites in air. The morphology of the surface on the composite films is studied, varying the total number and fluence of the applied laser pulses. A simple mechanism of the fabrication based on the evaporation of cyanoacrylate and the burning of carbon nanotubes is proposed. The conical peak structures of cyanoacrylate-carbon nanotube composite films show good field-emission properties. Similar structures are also observed on carbon nanotube arrays.

  18. [Toxic polyneuropathy after sniffing contact glue thinner (author's transl)].

    PubMed

    Altenkirch, H; Mager, J

    1976-02-06

    Four men aged 16 to 19 years who had sniffed contact glue ("Pattex") thinner almost daily for 3 to 7 years developed a pronounced polyneuropathy. They had to be admitted nearly at the same time. A uniform neurological syndrome similar to Landry's paralysis with progressive ascending symmetrical pareses had developed. Motor deficiencies and atrophies affected the lower extremities more frequently and more severely. Only minimal sensory disturbances were found. The disease shows remarkable similarity to the "glue-sniffing neuropathy" described in the US and Japan which is attributed to n-hexane.

  19. No Promoting Effect of Ethyl Tertiary-butyl Ether (ETBE) on Rat Urinary Bladder Carcinogenesis Initiated with N-Butyl-N-(4-hydroxybutyl)nitrosamine

    PubMed Central

    Hagiwara, Akihiro; Imai, Norio; Doi, Yuko; Suguro, Mayuko; Kawabe, Mayumi; Furukawa, Fumio; Nagano, Kasuke; Fukushima, Shoji

    2013-01-01

    The effects of ethyl tertiary-butyl ether (ETBE) on two-stage urinary bladder carcinogenesis in male F344 rats initiated with N-butyl-N-(4-hydroxybutyl)nitrosamine (BBN) were investigated at various dose levels with regard to possible promoting activity. Groups of 30 rats were given drinking water containing 500 ppm BBN, as an initiator, for 4 weeks and starting one week thereafter received ETBE by gavage (daily, 7 days/week) at dose levels of 0 (control), 100, 300, 500 or 1000 mg/kg/day until experimental week 36. No statistically significant differences in incidences of preneoplastic lesions, papillomas, and carcinomas of the urinary bladder were evident in rats treated with 100–1000 mg/kg/day ETBE as compared with control values. Furthermore, the average numbers of preneoplastic or neoplastic lesions per unit length of basement membrane in rats given 100–1000 mg/kg/day ETBE were also comparable to control values. However, papillomatosis of the urinary bladder was found in 4 out of 30 rats (13%) in the group given 1000 mg/kg/day ETBE, and soft stones in the urinary bladder were found in 3 out of these 4 rats. The results thus demonstrated that ETBE did not exert promotional activity on urinary bladder carcinogenesis. However, papillomatosis of the urinary bladder developed in small numbers of the rats given ETBE at 1000 mg/kg/day but not in rats given 500 mg/kg/day or lower doses. PMID:24526807

  20. Spiders Tune Glue Viscosity to Maximize Adhesion.

    PubMed

    Amarpuri, Gaurav; Zhang, Ci; Diaz, Candido; Opell, Brent D; Blackledge, Todd A; Dhinojwala, Ali

    2015-11-24

    Adhesion in humid conditions is a fundamental challenge to both natural and synthetic adhesives. Yet, glue from most spider species becomes stickier as humidity increases. We find the adhesion of spider glue, from five diverse spider species, maximizes at very different humidities that matches their foraging habitats. By using high-speed imaging and spreading power law, we find that the glue viscosity varies over 5 orders of magnitude with humidity for each species, yet the viscosity at maximal adhesion for each species is nearly identical, 10(5)-10(6) cP. Many natural systems take advantage of viscosity to improve functional response, but spider glue's humidity responsiveness is a novel adaptation that makes the glue stickiest in each species' preferred habitat. This tuning is achieved by a combination of proteins and hygroscopic organic salts that determines water uptake in the glue. We therefore anticipate that manipulation of polymer-salts interaction to control viscosity can provide a simple mechanism to design humidity responsive smart adhesives.

  1. Glue Sniffers with Special Needs.

    ERIC Educational Resources Information Center

    O'Connor, Denis

    1987-01-01

    Glue sniffing and solvent misuse have seriously affected children and teenagers throughout the United Kingdom. This article discusses glue sniffing in terms of prevalence, association with disability, physical and psychological effects, signs and symptoms, counseling for sniffers, and successful interventions including an approach using videotape…

  2. Fibrin glue for pilonidal sinus disease.

    PubMed

    Lund, Jon; Tou, Samson; Doleman, Brett; Williams, John P

    2017-01-13

    Pilonidal sinus disease is a common condition that mainly affects young adults. This condition can cause significant pain and impairment of normal activities. No consensus currently exists on the optimum treatment for pilonidal sinus and current therapies have various advantages and disadvantages. Fibrin glue has emerged as a potential treatment as both monotherapy and an adjunct to surgery. To assess the effects of fibrin glue alone or in combination with surgery compared with surgery alone in the treatment of pilonidal sinus disease. In December 2016 we searched: the Cochrane Wounds Specialised Register; CENTRAL; MEDLINE; Embase and CINAHL Plus. We also searched clinical trials registries and conference proceedings for ongoing and unpublished studies and scanned reference lists to identify additional studies. There were no restrictions with respect to language, date of publication or study setting. We included randomised controlled trials (RCTs) only. We included studies involving participants of all ages and studies conducted in any setting. We considered studies involving people with both new and recurrent pilonidal sinus. We included studies which evaluated fibrin glue monotherapy or as an adjunct to surgery. Two study authors independently extracted data and assessed risk of bias. We used standard methods expected by Cochrane. We included four RCTs with 253 participants, all were at risk of bias. One unpublished study evaluated fibrin glue monotherapy compared with Bascom's procedure, two studies evaluated fibrin glue as an adjunct to Limberg flap and one study evaluated fibrin glue as an adjunct to Karydakis flap.For fibrin glue monotherapy compared with Bascom's procedure, there were no data available for the primary outcomes of time to healing and adverse events. There was low-quality evidence of less pain on day one after the procedure with fibrin glue monotherapy compared with Bascom's procedure (mean difference (MD) -2.50, 95% confidence interval (CI

  3. An Ex Vivo Comparison of 2 Cyanoacrylate Skin Protectants.

    PubMed

    Gibson, Daniel J

    The purpose of these experiments was to compare 2 commercially available skin protectants with different chemical compositions. Two materially different skin protectants were applied to ex vivo pig skin, subjected to stresses, and the resulting skin was observed and analyzed. Using ex vivo pig skin, we sought to better understand the physical differences between a cyanoacrylate-based and a mixed cyanoacrylate/acrylic polymer-based skin protectant. A combination of imaging techniques and microscopic analyses was used to observe and quantify differences in layer thickness and the degree of steadfastness of the layers to liquid stresses. The experiments revealed that the solely cyanoacrylate-based protectant created a layer that was, on average, 5.1 times thicker than the mixed polymer product (p= 1.8 × 10). Observation via electron microscopy also revealed that the extent of coverage varied between the 2 products. In a final experiment, we observed that the mixed polymer product maintained a high degree of adhesiveness, which led to the removal of sheets of epithelium upon gentle blotting. The experiments revealed that while the 2 skin protectants share a common ingredient, both the quantity of that ingredient and the inclusion of other materials in one of them lead to substantially different properties when tested in the research setting.

  4. Acute and chronic glue sniffing effects and consequences of withdrawal on aggressive behavior.

    PubMed

    Bouchatta, Otmane; Ouhaz, Zakaria; Ba-Mhamed, Saadia; Kerekes, Nóra; Bennis, Mohamed

    2016-05-01

    Drug abuse act on brain mechanisms that cause a high-risk individual to engage in aggressive and violent behavior. While a drug-violence relationship exists, the nature of this relationship is often complex, with intoxication, neurotoxic, and withdrawal effects often being confused and/or confounded. Glue sniffing is often a springboard to the abuse of more addictive drugs. Despite its high prevalence and serious consequences, we know relatively little about the aggressive behavioral effects of volatile inhalants abuse, especially glue. The aim of the present study was to investigate the link between the duration of glue exposure, a common substance abuse problem in Morocco, and the level of aggressive behavior during withdrawal. For this we used the isolation-induced aggression model "residents" in three groups of mice. The first group served as control resident animals (n=10, without exposure); the second group as experimental resident mice (n=10) tested before and after acute (first day) and chronic exposure to the glue, and at 1 and 2weeks of withdrawal; and the third group of 10 intruder animals. The results showed that the number of attacks decreased (halved) and the latency of the first attack increased (doubled) following acute glue sniffing. However, the effects of chronic exposure and of 1week of withdrawal led to an increase in the intensity of agonistic encounters. After 2weeks of withdrawal, the intensity of aggressive behavior decreased again. These results indicated that chronic glue exposure and the first week of withdrawal are associated with increased aggression in mice. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Fibrin glue inhibits migration of ocular surface epithelial cells

    PubMed Central

    Yeung, A M; Faraj, L A; McIntosh, O D; Dhillon, V K; Dua, H S

    2016-01-01

    Purpose Fibrin glue has been used successfully in numerous ophthalmic surgical procedures. Recently, fibrin glue has been used in limbal stem cell transplantation to reduce both operative time and to negate the need for sutures. The aim of this study was to determine the effects of fibrin glue on epithelial cell migration in vitro. Methods Corneoscleral rims were split to retain the epithelial layer, Bowman's layer, and anterior stroma. Rims were cut into eight equal-sized pieces and were placed directly on culture plates or affixed with fibrin glue. Rims were maintained in culture for 25 days and epithelial cell growth was monitored. Cells were photographed to measure area or growth and immunofluorescence staining of explants for fibrin was performed. Results Explants that were glued demonstrated significantly delayed epithelial cell growth and migration as compared with explants without glue. By day 16, all fibrin glue had dissolved and coincided with onset of cell growth from glued explants. Cell growth commenced between days 3 and 4 for control explants without glue and around days 14–16 for explants with fibrin glue. Conclusions Fibrin glue delays epithelial cell migration by acting as a physical barrier and can potentially interfere with explant-derived limbal epithelial cell migration on to the corneal surface. We propose that glue should be used to attach the conjunctival frill of the limbal explant but care should be taken to ensure that the glue does not wrap around the explant if used to secure the explant as well. Strategic use of glue, to attach the recessed conjunctiva, can be advantageous in delaying conjunctival cell migration and reducing the need for sequential sector conjunctival epitheliectomy. PMID:27367746

  6. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasationmore » of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.« less

  7. Cycloolefin/cyanoacrylate (COCA) copolymers for 193-nm and 157-nm lithography

    NASA Astrophysics Data System (ADS)

    Dammel, Ralph R.; Sakamuri, Raj; Lee, Sang-Ho; Rahman, Dalil; Kudo, Takanori; Romano, Andrew R.; Rhodes, Larry F.; Lipian, John-Henry; Hacker, Cheryl; Barnes, Dennis A.

    2002-07-01

    The copolymerization reaction between methyl cyanoacrylate (MCA) and a variety of cycloolefins (CO) was investigated. Cycololefin/cyanoacrylate (COCA) copolymers were obtained in good yields and with lithographically interesting molecular weights for all cycoolefins studied. Anionic MCA homopolymerization could be largely suppressed using acetic acid. Based on NMR data, the copolymerization may tend to a 1:1 CO:MCA incorporation ratio but further work with better suppression of the anionic component is needed to confirm this. Lithographic tests on copolymers of appropriately substituted norbornenes and MCA showed semi-dense and isolated line performance down to 90 nm.

  8. The GlueX DIRC project

    DOE PAGES

    Stevens, J.; Barbosa, F.; Bessuille, J.; ...

    2016-07-20

    Here, the GlueX experiment was designed to search for and study the pattern of gluonic excitations in the meson spectrum produced through photoproduction reactions at a new tagged photon beam facility in Hall D at Jefferson Laboratory. The particle identification capabilities of the GlueX experiment will be enhanced by constructing a DIRC (Detection of Internally Reflected Cherenkov light) detector, utilizing components of the decommissioned BaBar DIRC. The DIRC will allow systematic studies of kaon final states that are essential for inferring the quark flavor content of both hybrid and conventional mesons. In this contribution, the design for the GlueX DIRCmore » will be discussed including new expansion volumes, read out with MaPMTs, that are currently under development.« less

  9. Occupational asthma due to methyl methacrylate and cyanoacrylates.

    PubMed Central

    Lozewicz, S; Davison, A G; Hopkirk, A; Burge, P S; Boldy, D A; Riordan, J F; McGivern, D V; Platts, B W; Davies, D; Newman Taylor, A J

    1985-01-01

    Five patients had asthma provoked by cyanoacrylates and one by methyl methacrylate, possibly because of the development of a specific hypersensitivity response. Acrylates have wide domestic as well as industrial uses, and inhalation of vapour emitted during their use can cause asthma. PMID:4071461

  10. Method for photochemical reduction of uranyl nitrate by tri-N-butyl phosphate and application of this method to nuclear fuel reprocessing

    DOEpatents

    De Poorter, Gerald L.; Rofer-De Poorter, Cheryl K.

    1978-01-01

    Uranyl ion in solution in tri-n-butyl phosphate is readily photochemically reduced to U(IV). The product U(IV) may effectively be used in the Purex process for treating spent nuclear fuels to reduce Pu(IV) to Pu(III). The Pu(III) is readily separated from uranium in solution in the tri-n-butyl phosphate by an aqueous strip.

  11. Safety of Synthetic Glue Used for Laparoscopic Prolapse Treatment.

    PubMed

    Sarasa Castelló, Núria; Toth, Alexandra; Canis, Michel; Botchorishvilli, Revaz

    2017-12-29

    We detected mesh erosion and serious postoperative complications in 3 women after performing laparoscopic promontofixation (LPF) using glue for mesh fixation. Glue, largely used in hernia surgery repair, is proposed by some gynecologic surgeons because it saves time and is easier to use than traditional sutures. We report 3 cases of postoperative complications after LPF in which glue had been used and provide research in the published literature about the use of glue in LPF. A research of glue use in gynecology mesh fixation was performed through PubMed on October 2016. The search was done using the Medical Subject Heading terms "POP" & "Laparoscopy" & "surgical Mesh" and the word either "glue" or "adhesive. Only 2 articles were found: Willecocq et al [1] and Estrade et al [2]. Neither study focused on postoperative complications. In this publication, we accurately edited video surgeries with an instructive purpose. University Hospital of Clermont-Ferrand, France. Patient A, a 65-year-old woman, complained of pelvic pain and vaginal discharge 1 month after LPF (polypropylene mesh and glue had been used). Wall mesh exposure and purulent discharge were noted. She received antibiotics and underwent mesh ablation surgery; debris of the glue was easily identified. Patient B, a 65-year-old lady with previous hysterectomy consulted for a bulging feeling in her vagina (classification: cystocele +2; rectocele +3 stage). An LPF was performed using polypropylene soft nonabsorbable mesh and glue. One month later, an apical defect of vaginal epithelialization was detected; she received long estrogenic local treatment but had to undergo surgery when presenting malodorous discharge and mesh exposure. The exposed mesh was removed, and pieces of glue were identified, having avoided mesh attachment. Patient C had a previous abdominal hysterectomy and promontofixation using a polyester mesh with glue. She consulted to us for vaginal mesh erosion covered with purulent discharge 3

  12. Anionic Photopolymerization of Methyl-2-Cyanoacrylate and Simultaneous Color Formation

    DTIC Science & Technology

    2000-11-15

    Anionic polymerization of methyl 2-cyanoacrylate initiated by photoinduced heterolysis of crystal violet leuconitrile (CVCN) and of malachite green leucohydroxide (MGOH) is demonstrated. Polymerization is accompanied by color formation.

  13. Bioinspired Nanoparticulate Medical Glues for Minimally Invasive Tissue Repair.

    PubMed

    Lee, Yuhan; Xu, Chenjie; Sebastin, Monisha; Lee, Albert; Holwell, Nathan; Xu, Calvin; Miranda Nieves, David; Mu, Luye; Langer, Robert S; Lin, Charles; Karp, Jeffrey M

    2015-11-18

    Delivery of tissue glues through small-bore needles or trocars is critical for sealing holes, affixing medical devices, or attaching tissues together during minimally invasive surgeries. Inspired by the granule-packaged glue delivery system of sandcastle worms, a nanoparticulate formulation of a viscous hydrophobic light-activated adhesive based on poly(glycerol sebacate)-acrylate is developed. Negatively charged alginate is used to stabilize the nanoparticulate surface to significantly reduce its viscosity and to maximize injectability through small-bore needles. The nanoparticulate glues can be concentrated to ≈30 w/v% dispersions in water that remain localized following injection. With the trigger of a positively charged polymer (e.g., protamine), the nanoparticulate glues can quickly assemble into a viscous glue that exhibits rheological, mechanical, and adhesive properties resembling the native poly(glycerol sebacate)-acrylate based glues. This platform should be useful to enable the delivery of viscous glues to augment or replace sutures and staples during minimally invasive procedures. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Bis(O-n-butyl dithio-carbonato-κS,S')bis-(pyridine-κN)manganese(II).

    PubMed

    Alam, Naveed; Ehsan, Muhammad Ali; Zeller, Matthias; Mazhar, Muhammad; Arifin, Zainudin

    2011-08-01

    The structure of the title manganese complex, [Mn(C(5)H(9)OS(2))(2)(C(5)H(5)N)(2)] or [Mn(S(2)CO-n-Bu)(2)(C(5)H(5)N)(2)], consists of discrete monomeric entities with Mn(2+) ions located on centres of inversion. The metal atom is coordinated by a six-coordinate trans-N(2)S(4) donor set with the pyridyl N atoms located in the apical positions. The observed slight deviations from octa-hedral geometry are caused by the bite angle of the bidentate κ(2)-S(2)CO-n-Bu ligands [69.48 (1)°]. The O(CH(2))(3)(CH(3)) chains of the O-n-butyl dithio-carbonate units are disordered over two sets of sites with an occupancy ratio of 0.589 (2):0.411 (2).

  15. Bio-inspired Nanoparticulate Medical Glues for Minimally Invasive Tissue Repair

    PubMed Central

    Lee, Yuhan; Xu, Chenjie; Sebastin, Monisha; Lee, Albert; Holwell, Nathan; Xu, Calvin; Miranda-Nieves, David; Mu, Luye; Lin, Charles

    2015-01-01

    Delivery of tissue glues through small-bore needles or trocars is critical for sealing holes, affixing medical devices, or attaching tissues together during minimally invasive surgeries. Inspired by the granule-packaged glue delivery system of sandcastle worms, we have developed a nanoparticulate formulation of a viscous hydrophobic light-activated adhesive based on poly(glycerol sebacate)-acrylate. Negatively charged alginate was used to stabilize the nanoparticulate surface to significantly reduce its viscosity and to maximize injectability through small-bore needles. The nanoparticulate glues can be concentrated to ~30w/v% dispersions in water that remain localized following injection. With the trigger of a positively charged polymer (e.g., protamine), the nanoparticulate glues can quickly assemble into a viscous glue that exhibits rheological, mechanical and adhesive properties resembling the native poly(glycerol sebacate)-acrylate based glues. This platform should be useful to enable the delivery of viscous glues to augment or replace sutures and staples during minimally invasive procedures. PMID:26227833

  16. Comparative trial of octyl-cyanoacrylate and silver sulfadiazine for the treatment of full-thickness skin wounds.

    PubMed

    Singer, A J; Berrutti, L; McClain, S A

    1999-01-01

    A prospective, randomized, blinded, controlled experimental trial was performed in pigs to compare the rates of reepithelialization of 126 full-thickness cutaneous 4-mm punches treated with an octyl-cyanoacrylate spray, silver sulfadiazine, or a dry gauze (controls). Full thickness biopsies were taken 7, 14, or 30 days later for histopathological evaluation of hematoxylin and eosin stained tissue sections by a dermatopathologist. The primary outcome measure was the proportion of wounds completely re-epithelialized at days 7 and 14. Secondary outcomes were the rates of infection, foreign body reactions, and the depth of any resulting cutaneous dells measured with a micrometer. Between-group comparisons were performed with ANOVA or Chi-square tests. Octyl-cyanoacrylate treated wounds re-epithelialized more slowly, as fewer wounds treated with octyl-cyanoacrylate were re-epithelialized at day 7 in comparison with silver sulfadiazine or control wounds (50% vs. 90% vs. 100%, p < 0.001). There were no infections or foreign body type reactions. Amounts of granulation tissue were similar among groups. Octyl-cyanoacrylate wounds were more depressed than silver sulfadiazine wounds at days 7 and 14 yet had similar histopathological characteristics at day 30. We conclude that treatment of small, full thickness cutaneous wounds with octyl-cyanoacrylate results in delayed re-epithelialization and dermal repair in comparison with silver sulfadiazine, yet it does not result in any foreign body-type reaction. However, by 30 days, histopathological wound characteristics were similar in all groups.

  17. [Application of skin adhesives in head and neck surgery: analysis of cosmetic results, applicability and cost-effectiveness of cyanoacrylate-based adhesives].

    PubMed

    Graefe, H; Wollenberg, B; Brocks, C

    2008-09-01

    In this work cyanoacrylate-based skin adhesives used in Germany for skin closure in head and neck surgery are compared with respect to ease of application, cost-effectiveness and cosmetic results. We compared 25 wounds sealed with a skin adhesive with 25 suture-sealed wounds. Bonding of surgical wounds with glue had a high level of acceptance in all patients. The tedious, time-consuming and sometimes painful postoperative removal of many sutures in patients is omitted. Patients can shower soon afterwards without additional protection as the adhesive provides a waterproof barrier. Problems of wound healing can immediately be detected through the transparent skin adhesive. Cosmetic long-term results of skin closure by adhesives are comparable to suture-sealed wounds. The adhesives available on the market differ mainly in the form of the applicator, the viscosity on application, as well as the strength after hardening. The application is easy to implement and significantly faster than conventional suturing. Apart from the cost savings of materials compared to the use of skin sutures and investment of Steri-Strips, expensive anesthesia and surgical time can also be saved.

  18. Preparation, in vitro and in vivo evaluation of polymeric nanoparticles based on hyaluronic acid-poly(butyl cyanoacrylate) and D-alpha-tocopheryl polyethylene glycol 1000 succinate for tumor-targeted delivery of morin hydrate

    PubMed Central

    Abbad, Sarra; Wang, Cheng; Waddad, Ayman Yahia; Lv, Huixia; Zhou, Jianping

    2015-01-01

    Herein, we describe the preparation of a targeted cellular delivery system for morin hydrate (MH), based on a low-molecular-weight hyaluronic acid-poly(butyl cyanoacrylate) (HA-PBCA) block copolymer. In order to enhance the therapeutic effect of MH, D-alpha-tocopheryl polyethylene glycol 1000 succinate (TPGS) was mixed with HA-PBCA during the preparation process. The MH-loaded HA-PBCA “plain” nanoparticle (MH-PNs) and HA-PBCA/TPGS “mixed” nanoparticles (MH-MNs) were concomitantly characterized in terms of loading efficiency, particle size, zeta potential, critical aggregation concentration, and morphology. The obtained MH-PNs and MH-MNs exhibited a spherical morphology with a negative zeta potential and a particle size less than 200 nm, favorable for drug targeting. Remarkably, the addition of TPGS resulted in about 1.6-fold increase in drug-loading. The in vitro cell viability experiment revealed that MH-MNs enhanced the cytotoxicity of MH in A549 cells compared with MH solution and MH-PNs. Furthermore, blank MNs containing TPGS exhibited selective cytotoxic effects against cancer cells without diminishing the viability of normal cells. In addition, the cellular uptake study indicated that MNs resulted in 2.28-fold higher cellular uptake than that of PNs, in A549 cells. The CD44 receptor competitive inhibition and the internalization pathway studies suggested that the internalization mechanism of the nanoparticles was mediated mainly by the CD44 receptors through a clathrin-dependent endocytic pathway. More importantly, MH-MNs exhibited a higher in vivo antitumor potency and induced more tumor cell apoptosis than did MH-PNs, following intravenous administration to S180 tumor-bearing mice. Overall, the results imply that the developed nanoparticles are promising vehicles for the targeted delivery of lipophilic anticancer drugs. PMID:25609946

  19. Cometabolism of Methyl tertiary Butyl Ether and Gaseous n-Alkanes by Pseudomonas mendocina KR-1 Grown on C5 to C8 n-Alkanes

    PubMed Central

    Smith, Christy A.; O'Reilly, Kirk T.; Hyman, Michael R.

    2003-01-01

    Pseudomonas mendocina KR-1 grew well on toluene, n-alkanes (C5 to C8), and 1° alcohols (C2 to C8) but not on other aromatics, gaseous n-alkanes (C1 to C4), isoalkanes (C4 to C6), 2° alcohols (C3 to C8), methyl tertiary butyl ether (MTBE), or tertiary butyl alcohol (TBA). Cells grown under carbon-limited conditions on n-alkanes in the presence of MTBE (42 μmol) oxidized up to 94% of the added MTBE to TBA. Less than 3% of the added MTBE was oxidized to TBA when cells were grown on either 1° alcohols, toluene, or dextrose in the presence of MTBE. Concentrated n-pentane-grown cells oxidized MTBE to TBA without a lag phase and without generating tertiary butyl formate (TBF) as an intermediate. Neither TBF nor TBA was consumed by n-pentane-grown cells, while formaldehyde, the expected C1 product of MTBE dealkylation, was rapidly consumed. Similar Ks values for MTBE were observed for cells grown on C5 to C8 n-alkanes (12.95 ± 2.04 mM), suggesting that the same enzyme oxidizes MTBE in cells grown on each n-alkane. All growth-supporting n-alkanes (C5 to C8) inhibited MTBE oxidation by resting n-pentane-grown cells. Propane (Ki = 53 μM) and n-butane (Ki = 16 μM) also inhibited MTBE oxidation, and both gases were also consumed by cells during growth on n-pentane. Cultures grown on C5 to C8 n-alkanes also exhibited up to twofold-higher levels of growth in the presence of propane or n-butane, whereas no growth stimulation was observed with methane, ethane, MTBE, TBA, or formaldehyde. The results are discussed in terms of their impacts on our understanding of MTBE biodegradation and cometabolism. PMID:14660389

  20. Chronic glue sniffing with transient central hypothyroidism and hypergonadotropism.

    PubMed

    Chen, Hua-Fen; Chen, Shwe-Winn; Chen, Peter; Su, Mei-Chin; See, Ting-Ting; Lee, Hsin-Yu

    2003-12-01

    Neuropsychiatric, gastrointestinal and muscular disorders associated with glue sniffing have been widely reported, but endocrinologic abnormalities of glue exposure are rarely mentioned in the literature. We report a 26-year old male patient, a chronic glue sniffer, who presented with weakness of both lower limbs. On physical examination, he had reduced muscle strength of his 4 limbs, especially in his lower limbs. Laboratory examination revealed hypokalemia with hyperchloremic metabolic acidosis. His thyroid function showed low TSH, T4, T3, free T4 and reverse T3 level. Other pituitary functions were normal apart from high FSH and LH level. TSH response to TRH stimulation was normal, but there was impaired T3 response to TRH. MRI of pituitary showed no significant changes. He continued glue sniffing after discharge. He repeatedly came to our hospital for recurrent hypokalemic paralysis. His serum T4 and free T4 level were low when he had certain amount of glue sniffing and it returned to normal after he stopped sniffing or sniffed less amount of glue. His serum T3 concentrations were normal most of the times thereafter. His FSH and LH level were persistently elevated, even after he did not sniff glue for 2 weeks. Low free T4, TSH and reverse T3 level associated with glue sniffing in our patient were compatible with central hypothyroidism. Toluene, a neurotoxic organic solvent, is present in glues. Being highly lipophilic, it can easily enter and is retained within the lipid-rich nervous system after being inhaled. Like other organic solvents, toluene has been shown to affect dopaminergic and adrenergic turnover within various parts of the brain. The effects on these neurotransmitters could lead to abnormal secretion of pituitary hormones resulting in transient central hypothyroidism and abnormal gonadotropin levels. Long-term harmful effect of central hypothyroidism and chronic influence of abnormal gonadotropins to reproduction function needs further observation.

  1. Strong, low-density nanocomposites by chemical vapor deposition and polymerization of cyanoacrylates on aminated silica aerogels.

    PubMed

    Boday, Dylan J; Stover, Robert J; Muriithi, Beatrice; Keller, Michael W; Wertz, Jason T; Defriend Obrey, Kimberly A; Loy, Douglas A

    2009-07-01

    Strong polymer-silica aerogel composites were prepared by chemical vapor deposition of cyanoacrylate monomers onto amine-modified aerogels. Amine-modified silica aerogels were prepared by copolymerizing small amounts of (aminopropyl)triethoxysilane with tetraethoxysilane. After silation of the aminated gels with hexamethyldisilazane, they were dried as aerogels using supercritical carbon dioxide processing. The resulting aerogels had only the amine groups as initiators for the cyanoacrylate polymerizations, resulting in cyanoacrylate macromolecules that were higher in molecular weight than those observed with unmodified silica and that were covalently attached to the silica surface. Starting with aminated silica aerogels that were 0.075 g/cm(3) density, composite aerogels were made with densities up to 0.220 g/cm(3) and up to 31 times stronger (flexural strength) than the precursor aerogel and about 2.3 times stronger than an unmodified silica aerogel of the same density.

  2. Photoproduction of the Cascade Baryons at GlueX

    NASA Astrophysics Data System (ADS)

    Ernst, Ashley; GlueX Collaboration

    2017-09-01

    Multi-strange baryons play an important role in understanding the strong interaction and despite their importance, little is known about such hyperons. Almost all knowledge of the Cascades today stems from Kaon-nucleon interactions in bubble chamber experiments performed in the 1960s and 1970s, of which only the octet and decuplet ground states, Ξ (1320) and Ξ (1530) respectively, are well established. This research uses the GlueX experiment at Jefferson Laboratory to map out the spectrum of doubly-strange Cascade resonances, as well as to measure the spin-parity for each of the detected resonances. The first physics run for GlueX has recently been completed and a clear signature of the Ξ (1320) is observed. The systematics of the Cascade spectrum will be presented motivated by prior discoveries in the N* program. This work was supported by the U.S. Department of Energy Grant DE-FG02-92ER40735 and National Science Foundation Grant 1449440.

  3. Metabolism and elimination of methyl, iso- and n-butyl paraben in human urine after single oral dosage.

    PubMed

    Moos, Rebecca K; Angerer, Jürgen; Dierkes, Georg; Brüning, Thomas; Koch, Holger M

    2016-11-01

    Parabens are used as preservatives in personal care and consumer products, food and pharmaceuticals. Their use is controversial because of possible endocrine disrupting properties. In this study, we investigated metabolism and urinary excretion of methyl paraben (MeP), iso-butyl paraben (iso-BuP) and n-butyl paraben (n-BuP) after oral dosage of deuterium-labeled analogs (10 mg). Each volunteer received one dosage per investigated paraben separately and at least 2 weeks apart. Consecutive urine samples were collected over 48 h. In addition to the parent parabens (free and conjugated) which are already used as biomarkers of internal exposure and the known but non-specific metabolites, p-hydroxybenzoic acid (PHBA) and p-hydroxyhippuric acid (PHHA), we identified new, oxidized metabolites with hydroxy groups on the alkyl side chain (3OH-n-BuP and 2OH-iso-BuP) and species with oxidative modifications on the aromatic ring. MeP represented 17.4 % of the dose excreted in urine, while iso-BuP represented only 6.8 % and n-BuP 5.6 %. Additionally, for iso-BuP, about 16 % was excreted as 2OH-iso-BuP and for n-BuP about 6 % as 3OH-n-BuP. Less than 1 % was excreted as ring-hydroxylated metabolites. In all cases, PHHA was identified as the major but non-specific metabolite (57.2-63.8 %). PHBA represented 3.0-7.2 %. For all parabens, the majority of the oral dose captured by the above metabolites was excreted in the first 24 h (80.5-85.3 %). Complementary to the parent parabens excreted in urine, alkyl-chain-oxidized metabolites of the butyl parabens are introduced as valuable and contamination-free biomarkers of exposure.

  4. Caged Molecular Glues as Photoactivatable Tags for Nuclear Translocation of Guests in Living Cells.

    PubMed

    Arisaka, Akio; Mogaki, Rina; Okuro, Kou; Aida, Takuzo

    2018-02-21

    We developed dendritic caged molecular glues ( Caged Glue-R) as tags for nucleus-targeted drug delivery, whose multiple guanidinium ion (Gu + ) pendants are protected by an anionic photocleavable unit (butyrate-substituted nitroveratryloxycarbonyl; BA NVOC). Negatively charged Caged Glue-R hardly binds to anionic biomolecules because of their electrostatic repulsion. However, upon exposure of Caged Glue-R to UV light or near-infrared (NIR) light, the BA NVOC groups of Caged Glue-R are rapidly detached to yield an uncaged molecular glue ( Uncaged Glue-R) that carries multiple Gu + pendants. Because Gu + forms a salt bridge with PO 4 - , Uncaged Glue-R tightly adheres to anionic biomolecules such as DNA and phospholipids in cell membranes by a multivalent salt-bridge formation. When tagged with Caged Glue-R, guests can be taken up into living cells via endocytosis and hide in endosomes. However, when the Caged Glue-R tag is photochemically uncaged to form Uncaged Glue-R, the guests escape from the endosome and migrate into the cytoplasm followed by the cell nucleus. We demonstrated that quantum dots (QDs) tagged with Caged Glue-R can be delivered efficiently to cell nuclei eventually by irradiation with light.

  5. ATOM TRANSFER RADICAL POLYMERIZATION OF N-BUTYL METHACRYLATE IN AQUEOUS DISPERSED SYSTEMS: A MINIEMULSION APPROACH. (R826735)

    EPA Science Inventory

    Ultrasonication was applied in combination with a hydrophobe for the copper-mediated atom transfer radical polymerization of n-butyl methacrylate in an aqueous dispersed system. A controlled polymerization was successfully achieved, as demonstrated by a linear correlation between...

  6. Percutaneous embolization of persistent low-output enterocutaneous fistulas.

    PubMed

    Cambj Sapunar, Liana; Sekovski, Budimir; Matić, Dario; Tripković, Andro; Grandić, Leo; Družijanić, Nikica

    2012-09-01

    To present and retrospectively evaluate the technique of percutaneous embolization of chronic enterocutaneous fistulas (ECFs) using n-butyl-2-cyanoacrylate and Lipiodol under fluoroscopic guidance. Six patients with a total of seven post-operative low-output ECFs of the large intestine were treated. After fistulography a hydrophilic guide wire and a catheter were advanced through the ECF into the intestine. After dilation of the bowel with saline and contrast medium, the catheter was withdrawn into the enteric orifice and glue together with Lipiodol was injected while simultaneously pulling the catheter. Complete closure of all seven fistulas was achieved. There were no peri-procedural complications. In one patient 1 month following embolization a low-output enteric discharge was observed, but the ECF spontaneously healed 5 days later. In one patient 18 months after the embolization a new perforation due to diverticulitis close to the embolization site occurred and resection of the sigmoid colon was performed. One patient needed reoperation due to a recurrence of rectal carcinoma. In our series of patients, the presented technique of percutaneous embolization proved to be efficacious and easy to perform. It may have potential as a first-line treatment of low-output ECFs but a prospective study with a larger series of patients and a longer follow-up is required.

  7. Albumen Glue, New Material for Conjunctival Graft Surgery, an Animal Experiment

    NASA Astrophysics Data System (ADS)

    Kartiwa, A.; Miraprahesti, R.; Sovani, I.; Enus, S.; Boediono, A.

    2017-02-01

    Attach conjunctival graft commonly used are suture technique and fibrin glue. This study was to investigate albumen glue as an alternative to suture technique in attaching conjunctival graft in rabbits. Aim of this study was to compare the conjunctival wound healing between albumen glue and suture technique in rabbit eye as a model. There was an experimental animal study included 32 eyes (16 rabbits) in PT. Bio Farma (Persero) and Histology Laboratory, Faculty of Medicine, Padjadjaran University from March 2014 to July 2104. The study consisted of albumen glue group and suture technique group. The examination included the comparison of conjunctival graft attachment and histologic examination by microscopically was done to obtain the wound gap, then analyze by Mann-Whitney test. The results indicated that the graft attachment was significantly better-using albumen glue (grade 4) compared to suture (grade 2-3) on day-1 after surgery (p=0,000). The wound gap was smaller using albumen glue (0-0,33 μm versus 5,33-14 μm ; p=0,0005) on 10 minutes after surgery and 0 μm versus 0,33-4 μm ; p=0,0005 on day-7 after surgery. In conclusion, the graft attachment using albumen glue was better and the wound gap was smaller using albumen glue than suture technique.

  8. Ground-State Distortion in N-Acyl-tert-butyl-carbamates (Boc) and N-Acyl-tosylamides (Ts): Twisted Amides of Relevance to Amide N-C Cross-Coupling.

    PubMed

    Szostak, Roman; Shi, Shicheng; Meng, Guangrong; Lalancette, Roger; Szostak, Michal

    2016-09-02

    Amide N-C(O) bonds are generally unreactive in cross-coupling reactions employing low-valent transition metals due to nN → π*C═O resonance. Herein we demonstrate that N-acyl-tert-butyl-carbamates (Boc) and N-acyl-tosylamides (Ts), two classes of acyclic amides that have recently enabled the development of elusive amide bond N-C cross-coupling reactions with organometallic reagents, are intrinsically twisted around the N-C(O) axis. The data have important implications for the design of new amide cross-coupling reactions with the N-C(O) amide bond cleavage as a key step.

  9. Compounds from silicones alter enzyme activity in curing barnacle glue and model enzymes.

    PubMed

    Rittschof, Daniel; Orihuela, Beatriz; Harder, Tilmann; Stafslien, Shane; Chisholm, Bret; Dickinson, Gary H

    2011-02-17

    Attachment strength of fouling organisms on silicone coatings is low. We hypothesized that low attachment strength on silicones is, in part, due to the interaction of surface available components with natural glues. Components could alter curing of glues through bulk changes or specifically through altered enzyme activity. GC-MS analysis of silicone coatings showed surface-available siloxanes when the coatings were gently rubbed with a cotton swab for 15 seconds or given a 30 second rinse with methanol. Mixtures of compounds were found on 2 commercial and 8 model silicone coatings. The hypothesis that silicone components alter glue curing enzymes was tested with curing barnacle glue and with commercial enzymes. In our model, barnacle glue curing involves trypsin-like serine protease(s), which activate enzymes and structural proteins, and a transglutaminase which cross-links glue proteins. Transglutaminase activity was significantly altered upon exposure of curing glue from individual barnacles to silicone eluates. Activity of purified trypsin and, to a greater extent, transglutaminase was significantly altered by relevant concentrations of silicone polymer constituents. Surface-associated silicone compounds can disrupt glue curing and alter enzyme properties. Altered curing of natural glues has potential in fouling management.

  10. Adhesion modulation using glue droplet spreading in spider capture silk

    PubMed Central

    Zhang, Ci; Blackledge, Todd A.

    2017-01-01

    Orb web spiders use sticky capture spiral silk to retain prey in webs. Capture spiral silk is composed of an axial fibre of flagelliform silk covered with glue droplets that are arranged in a beads-on-a-string morphology that allows multiple droplets to simultaneously extend and resist pull off. Previous studies showed that the adhesion of capture silk is responsive to environmental humidity, increasing up to an optimum humidity that varied among different spider species. The maximum adhesion was hypothesized to occur when the viscoelasticity of the glue optimized contributions from glue spreading and bulk cohesion. In this study, we show how glue droplet shape during peeling contributes significantly to capture silk adhesion. Both overspreading and underspreading of glue droplets reduces adhesion through changes in crack propagation and failure regime. Understanding the mechanism of stimuli-responsive adhesion of spider capture silk will lead to new designs for smarter adhesives. PMID:28490605

  11. Adhesion modulation using glue droplet spreading in spider capture silk.

    PubMed

    Amarpuri, Gaurav; Zhang, Ci; Blackledge, Todd A; Dhinojwala, Ali

    2017-05-01

    Orb web spiders use sticky capture spiral silk to retain prey in webs. Capture spiral silk is composed of an axial fibre of flagelliform silk covered with glue droplets that are arranged in a beads-on-a-string morphology that allows multiple droplets to simultaneously extend and resist pull off. Previous studies showed that the adhesion of capture silk is responsive to environmental humidity, increasing up to an optimum humidity that varied among different spider species. The maximum adhesion was hypothesized to occur when the viscoelasticity of the glue optimized contributions from glue spreading and bulk cohesion. In this study, we show how glue droplet shape during peeling contributes significantly to capture silk adhesion. Both overspreading and underspreading of glue droplets reduces adhesion through changes in crack propagation and failure regime. Understanding the mechanism of stimuli-responsive adhesion of spider capture silk will lead to new designs for smarter adhesives. © 2017 The Author(s).

  12. Cohort study on respiratory and neurological disorders among workers in a bone glue factory in Egypt.

    PubMed

    Al-Batanony, M A; Abdel-Rasoul, G M; Abu-Salem, M A; Al-Ahmar, I A; Al-Badry, A S

    2012-04-01

    Glues are strong, liquid adhesive derived from animal tissues. It has been shown that glue sniffing is associated with demyelinating polyneuropathy. The low molecular weight agents which cause occupational lung disease have generally included the isocyanates exposure to which could result in asthma among workers. Toluene is also used widely in glue and adhesive industry and households where toluene exposure and abuse can occur. To study some respiratory and neurological disorders that may arise in workers in a bone glue factory in Queisna industrial zone, Menoufyia governorate, Egypt. In a historical cohort study, the exposed participants (n = 50) were recruited from workers in a bone glue factory in Queisna industrial zone, Menoufyia governorate. The unexposed group was selected from workers' relatives who had never worked in glue industry. All participants completed a pre-designed questionnaire on personal and occupational histories. Pulmonary function tests as well as electromyography (EMG) were performed for all participants. Urinary hippuric acid was also measure in all participants. The prevalence of cough, asthmatic attacks and paresthesia were significantly higher among exposed than unexposed participants. Abnormal spirometric measurements (particularly towards obstruction), abnormal EMG and positive urinary hippuric acid were significantly more prevalent among exposed than unexposed group. Spirometry and EMG should be included in the periodic medical examination for exposed workers for early detection of respiratory and neurological disorders. Urinary hippuric acid could be a useful indicator of the nerve conduction abnormalities and should be measured periodically for these workers.

  13. Research on preparation of phosphate-modified animal glue binder for foundry use

    NASA Astrophysics Data System (ADS)

    Wang, Tian-Shu; Liu, Wei-Hua; Li, Ying-Min

    2018-03-01

    In this paper, three phosphates were used as modifiers to modify animal glue binder. The structural characteristics and thermal properties of animal glue binder treated with phosphates were studied by Fourier transform-infrared spectroscopy, gel permeation chromatography and derivative thermogravimetric analysis. The results showed that the modified animal glue binder had better sand tensile strength and lower viscosity than untreated animal glue binder. The best modification process was as follows: the optimal amount of sodium carbonate was 4 wt% to animal glue; the optimal weight ratio of the modifiers was sodium pyrophosphate : sodium tripolyphosphate : sodium hexametaphosphate : animal glue = 3 : 3 : 4 : 100, and the optimal reaction should be performed at 80°C for a reaction time of 120 min. A final tensile strength of approximately 3.20 MPa was achieved and the viscosity value was approximately 880 mPa s.

  14. Migratory Patterns of American Shad (Alosa Sapidissima) Revealed by Natural Geochemical Tags in Otoliths

    DTIC Science & Technology

    2007-02-01

    cyanoacrylic glue. Mounted otoliths were ground to the midplane using fine-grained lapping film. Ground otoliths were examined for oxytetracycline marks...were mounted and ground to the midplane with fine-grained lapping film. Ground otoliths were examined for oxytetracycline marks under a UV light source

  15. Compounds from Silicones Alter Enzyme Activity in Curing Barnacle Glue and Model Enzymes

    PubMed Central

    Rittschof, Daniel; Orihuela, Beatriz; Harder, Tilmann; Stafslien, Shane; Chisholm, Bret; Dickinson, Gary H.

    2011-01-01

    Background Attachment strength of fouling organisms on silicone coatings is low. We hypothesized that low attachment strength on silicones is, in part, due to the interaction of surface available components with natural glues. Components could alter curing of glues through bulk changes or specifically through altered enzyme activity. Methodology/Principal Findings GC-MS analysis of silicone coatings showed surface-available siloxanes when the coatings were gently rubbed with a cotton swab for 15 seconds or given a 30 second rinse with methanol. Mixtures of compounds were found on 2 commercial and 8 model silicone coatings. The hypothesis that silicone components alter glue curing enzymes was tested with curing barnacle glue and with commercial enzymes. In our model, barnacle glue curing involves trypsin-like serine protease(s), which activate enzymes and structural proteins, and a transglutaminase which cross-links glue proteins. Transglutaminase activity was significantly altered upon exposure of curing glue from individual barnacles to silicone eluates. Activity of purified trypsin and, to a greater extent, transglutaminase was significantly altered by relevant concentrations of silicone polymer constituents. Conclusions/Significance Surface-associated silicone compounds can disrupt glue curing and alter enzyme properties. Altered curing of natural glues has potential in fouling management. PMID:21379573

  16. [n-Butyl Alcohol-soluble Chemical Constituents of Psidium guajava Leaves].

    PubMed

    Chen, Gang; Wan, Kai-hua; Fu, Hui-zheng; Yan, Qing-wei

    2015-03-01

    To study the chemical constituents of the leaves of Psidium guajava. The chemical constituents were isolated by column chromatography on silica gel, Sephadex LH-20 and MPLC. Their chemical structures were elucidated on the basis of special analysis. Seven compounds were isolated from n-butyl alcohol fraction, whose structures were elucidated as morin-3-O-α-L-arabopyranoside (1), morin-3-O-α-L-iyxopyranoside (2), 2,6-dihydroxy-4-O-β-D-glucopyranosyl-benzophenone (3), casuarictin (4),2,6-dihydroxy-3,5-dimethyl-4-O-(6"-O-galloyl-β-D-glucopyranosyl)-benzophenone(5), globulusin A(6), and kaempferol-3-O-β-D-(6"-galloyl) galactopyranoside (7). Compounds 3 and 5 ~ 7 are isolated from this plant for the first time.

  17. Echocardiographic demonstration of intracardiac glue after endoscopic obturation of gastroesophageal varices.

    PubMed

    Gallet, B; Zemour, G; Saudemont, J P; Renard, P; Hillion, M L; Hiltgen, M

    1995-01-01

    Systemic embolism is an unusual complication of endoscopic obturation of gastroesophageal varices with glue. This report describes a case of cerebral embolism after this procedure. Intracardiac glue within the left atrium was demonstrated by echocardiography. Cardiac fluoroscopy demonstrated an abnormal vessel connecting periesophageal veins with the right upper pulmonary vein. Cardiac surgery was performed. Intracardiac glue was removed and the entering orifice of the abnormal vessel in the right upper pulmonary vein was sutured. To our knowledge, this is the first reported case of intracardiac glue after variceal obturation. Echocardiography is useful in the diagnosis of this rare complication.

  18. Microemulsions containing lecithin and sugar-based surfactants: nanoparticle templates for delivery of proteins and peptides.

    PubMed

    Graf, Anja; Ablinger, Elisabeth; Peters, Silvia; Zimmer, Andreas; Hook, Sarah; Rades, Thomas

    2008-02-28

    Two pseudo-ternary systems comprising isopropyl myristate, soybean lecithin, water, ethanol and either decyl glucoside (DG) or capryl-caprylyl glucoside (CCG) as surfactant were investigated for their potential to form microemulsion templates to produce nanoparticles as drug delivery vehicles for proteins and peptides. All microemulsion and nanoparticle compounds used were pharmaceutically acceptable and biocompatible. Phase diagrams were established and characterized using polarizing light microscopy, viscosity, conductivity, electron microscopy, differential scanning calorimetry and self-diffusion NMR. An area in the phase diagrams containing optically isotropic, monophasic systems was designated as the microemulsion region and systems therein identified as solution-type microemulsions. Poly(alkylcyanoacrylate) nanoparticles prepared by interfacial polymerisation from selected microemulsions ranged from 145 to 660nm in size with a unimodal size distribution depending on the type of monomer (ethyl (2) or butyl (2) cyanoacrylate) and microemulsion template. Generally larger nanoparticles were formed by butyl (2) cyanoacrylate. Insulin was added as a model protein and did not alter the physicochemical behaviour of the microemulsions or the morphology of the nanoparticles. However, insulin-loaded nanoparticles in the CCG containing system decreased in size when using butyl (2) cyanoacrylate. This study shows that microemulsions containing sugar-based surfactants are suitable formulation templates for the formation of nanoparticles to deliver peptides.

  19. Fibrin glue as agent for sealing corneal and conjunctival wound leaks.

    PubMed

    Scalcione, C; Ortiz-Vaquerizas, D; Said, D G; Dua, H S

    2018-02-01

    PurposeTo describe a novel use of fibrin glue in managing leaking blebs and leaking wounds following trauma or surgery.MethodsInterventional case series.ResultsWe report eight patients, including three where intra-operative or immediate post-penetrating keratoplasty recalcitrant leaks from the graft-host junction and/or openings created by the needle pass, were noted. All three had thin recipient beds in the sector of leak. This was managed by intra-cameral injection of fibrin glue in the affected quadrant. This stopped the leak and allowed the defect to heal. One patient of Descemets-stripping-endothelial-keratoplasty had leak from the surgical wound, which was also sealed with fibrin glue. Two patients with leaking glaucoma-surgery-related blebs were treated with intra-bleb injection of fibrin glue to stop the leak. One patient with a penetrating corneal injury with a metal wire had a brisk leak upon removal of the wire. This was sealed with fibrin glue. Another patient of chemical burn with spontaneous leaks was managed by glue injection in the perforations. Transient rise of intraocular pressure in one patient with a leaking bleb was the only adverse event recorded.ConclusionThis novel adaptation of the application of fibrin glue can help to deal with persistent intra-operative, post-operative and traumatic aqueous and air leaks.

  20. The influence of pterygium morphology on fibrin glue conjunctival autografting pterygium surgery.

    PubMed

    Sandra, Sekelj; Zeljka, Janjetovic; Zeljka, Vukovic Arar; Kristian, Samardzic; Ivana, Aric

    2014-02-01

    To evaluate the influence of pterygium morphology on the efficacy and safety of fibrin glue in pterygium surgery with conjunctival autografting. A prospective case series. During a period of 15 months, 45 patients (51 eyes) were recruited from the General Hospital for pterygium surgery. Seven eyes (13.73 %) were operated on for a recurrent pterygium. Autologous conjunctiva was harvested from the superior bulbar conjunctiva and fixed with fibrin glue. The pterygia were preoperatively divided into atrophic/grade 1 (n = 18; 35.29 %), intermediate/grade 2 (n = 22; 43.14 %) or fleshy/grade 3 (n = 11; 21.57 %) according to clinical morphology. Patients were evaluated for intraoperative and postoperative complications and recurrence rates. The success rate was defined by no pterygium recurrences. Patients with 2-year follow-ups were included in this study. Fifty-one patients (21 females/30 males) with a mean age of 60-65 years (range 24-87 years) took part in the study. All patients completed the study. No intraoperative complications were noted. Postsurgical complications included graft edema (n = 4; 7.8 %), graft hyperemia (n = 2; 3.8 %), and graft dislocation (n = 3; 5.9 %); these complications were transient. One graft unfastened completely (2 %) and five pterygium recurrences occurred (n = 5; 9.8 %). The overall success rate was 90 % after 2 years. In grade I group there were no recurrences, in grade 2 group there were two recurrences, and in grade 3 group there were three recurrences. There were significantly more recurrences in grade 3 group than in grade 2 group. There were more recurrences in both groups than in group 1 (60 vs 40 vs 0 % of all recurrences, p ≤ 0.05). The use of fibrin glue is a safe, easy and effective technique for attaching the conjunctival autograft in pterygium surgery. The morphology of pterygium influences recurrence rates, without significance for intraoperative and postoperative complications.

  1. Bis(O-n-butyl dithio­carbonato-κ2 S,S′)bis­(pyridine-κN)manganese(II)

    PubMed Central

    Alam, Naveed; Ehsan, Muhammad Ali; Zeller, Matthias; Mazhar, Muhammad; Arifin, Zainudin

    2011-01-01

    The structure of the title manganese complex, [Mn(C5H9OS2)2(C5H5N)2] or [Mn(S2CO-n-Bu)2(C5H5N)2], consists of discrete monomeric entities with Mn2+ ions located on centres of inversion. The metal atom is coordinated by a six-coordinate trans-N2S4 donor set with the pyridyl N atoms located in the apical positions. The observed slight deviations from octa­hedral geometry are caused by the bite angle of the bidentate κ2-S2CO-n-Bu ligands [69.48 (1)°]. The O(CH2)3(CH3) chains of the O-n-butyl dithio­carbonate units are disordered over two sets of sites with an occupancy ratio of 0.589 (2):0.411 (2). PMID:22090847

  2. Urease Inhibition in the Presence of N-(n-Butyl)thiophosphoric Triamide, a Suicide Substrate: Structure and Kinetics.

    PubMed

    Mazzei, Luca; Cianci, Michele; Contaldo, Umberto; Musiani, Francesco; Ciurli, Stefano

    2017-10-10

    The nickel-dependent enzyme urease is a virulence factor for a large number of pathogenic and antibiotic-resistant bacteria, as well as a negative factor for the efficiency of soil nitrogen fertilization for crop production. The use of urease inhibitors to offset these effects requires knowledge, at a molecular level, of their mode of action. The 1.28 Å resolution structure of the enzyme-inhibitor complex obtained upon incubation of Sporosarcina pasteurii urease with N-(n-butyl)thiophosphoric triamide (NBPT), a molecule largely utilized in agriculture, reveals the presence of the monoamidothiophosphoric acid (MATP) moiety, obtained upon enzymatic hydrolysis of the diamide derivative of NBPT (NBPD) to yield n-butyl amine. MATP is bound to the two Ni(II) ions in the active site of urease using a μ 2 -bridging O atom and terminally bound O and NH 2 groups, with the S atom of the thiophosphoric amide pointing away from the metal center. The mobile flap modulating the size of the active site cavity is found in the closed conformation. Docking calculations suggest that the interaction between urease in the open flap conformation and NBPD involves a role for the conserved αArg339 in capturing and orienting the inhibitor prior to flap closure. Calorimetric and spectrophotometric determinations of the kinetic parameters of this inhibition indicate the occurrence of a reversible slow inhibition mode of action, characterized, for both bacterial and plant ureases, by a very small value of the dissociation constant of the urease-MATP complex. No need to convert NBPT to its oxo derivative NBPTO, as previously proposed, is necessary for urease inhibition.

  3. Mesh fixation in laparoscopic incisional hernia repair: glue fixation provides attachment strength similar to absorbable tacks but differs substantially in different meshes.

    PubMed

    Rieder, Erwin; Stoiber, Martin; Scheikl, Verena; Poglitsch, Marcus; Dal Borgo, Andrea; Prager, Gerhard; Schima, Heinrich

    2011-01-01

    Laparoscopic ventral hernia repair has gained popularity among minimally invasive surgeons. However, mesh fixation remains a matter of discussion. This study was designed to compare noninvasive fibrin-glue attachment with tack fixation of meshes developed primarily for intra-abdominal use. It was hypothesized that particular mesh structures would substantially influence detachment force. For initial evaluation, specimens of laminated polypropylene/polydioxanone meshes were anchored to porcine abdominal walls by either helical titanium tacks or absorbable tacks in vitro. A universal tensile-testing machine was used to measure tangential detachment forces (TF). For subsequent experiments of glue fixation, polypropylene/polydioxanone mesh and 4 additional meshes with diverse particular mesh structure, ie, polyvinylidene fluoride/polypropylene mesh, a titanium-coated polypropylene mesh, a polyester mesh bonded with a resorbable collagen, and a macroporous condensed PTFE mesh were evaluated. TF tests revealed that fibrin-glue attachment was not substantially different from that achieved with absorbable tacks (median TF 7.8 Newton [N], range 1.3 to 15.8 N), but only when certain open porous meshes (polyvinylidene fluoride/polypropylene mesh: median 6.2 N, range 3.4 to 10.3 N; titanium-coated polypropylene mesh: median 5.2 N, range 2.1 to 11.7 N) were used. Meshes coated by an anti-adhesive barrier (polypropylene/polydioxanone mesh: median 3.1 N, range 1.7 to 5.8 N; polyester mesh bonded with a resorbable collagen: median 1.3 N, range 0.5 to 1.9 N), or the condensed PTFE mesh (median 3.1 N, range 2.1 to 7.0 N) provided a significantly lower TF (p < 0.01). Fibrin glue appears to be an appealing noninvasive option for mesh fixation in laparoscopic ventral hernia repair, but only if appropriate meshes are used. Glue can also serve as an adjunct to mechanical fixation to reduce the number of invasive tacks. Copyright © 2010 American College of Surgeons. Published by Elsevier

  4. Fibrin Glue Improves the Therapeutic Effect of MSCs by Sustaining Survival and Paracrine Function

    PubMed Central

    Kim, Inok; Lee, Sung Koo; Yoon, Jung In; Kim, Da Eun

    2013-01-01

    Fibrin glue has been widely investigated as a cell delivery vehicle for improving the therapeutic effects of mesenchymal stem cells (MSCs). Implanted MSCs produce their therapeutic effects by secreting paracrine factors and by replacing damaged tissues after differentiation. While the influence of fibrin glue on the differentiation potential of MSCs has been well documented, its effect on paracrine function of MSCs is largely unknown. Herein we investigated the influence of fibrin glue on the paracrine effects of MSCs. MSCs were isolated from human adipose tissue. The effects of fibrin glue on survival, migration, secretion of growth factors, and immune suppression of MSCs were investigated in vitro. MSCs in fibrin glue survived and secreted growth factors such as the vascular endothelial growth factor (VEGF) and hepatocyte growth factor (HGF) over 14 days. VEGF and immune modulators, including the transforming growth factor (TGF)-β1 and prostaglandin E2, secreted from MSCs in fibrin glue significantly increased under inflammatory conditions. Thus, MSCs in fibrin glue effectively suppressed immune reactions. In addition, fibrin glue protected the MSCs from oxidative stress and prevented human dermal fibroblast death induced by exposure to extreme stress. In contrast, MSCs within fibrin glue hardly migrated. These results suggest that fibrin glue may sustain survival of implanted MSCs and their paracrine function. Our results provide a mechanistic data to allow further development of MSCs with fibrin glue as a clinical treatment. PMID:23701237

  5. Molecular mechanism for adhesion in humid conditions - lessons from spider glue

    NASA Astrophysics Data System (ADS)

    Amarpuri, Gaurav; Singla, Saranshu; Dhopatkar, Nishad; Blackledge, Todd; Dhinojwal, Ali

    Adhesion in humid conditions is a fundamental challenge for both natural and synthetic adhesives. Water lubricates the interface between the adhesive and the substrate resulting in an interfacial failure at high humidity. Yet, glue from most spider species fail cohesively at high humidity, and the spider species from wet habitat show an increase in adhesion with humidity. We use tensile testing, microscopy and surface sensitive spectroscopy techniques to probe the mechanism of spider glue adhesion under high humidity. Humidity responsive structural changes in the glue structure are observed both at the interface and in bulk. However, the humidity responsiveness is lost after washing the water soluble low molecular weight molecules (LMM) from the glue. Many natural systems display a functional response to their environment, but spider glue's humidity responsiveness is a novel adaptation that makes the glue stickiest in each species' preferred habitat. This tuning is achieved by a combination of proteins and hygroscopic LMM that respond to humidity in a unique way. We therefore anticipate that manipulation of polymer-LMM interaction can provide a simple mechanism to design humidity responsive smart adhesives. We acknowledge support from National Science Foundation Grant IOS-1257719.

  6. Withstand pressure of a simple fibrin glue sealant: experimental study of mimicked sellar reconstruction in extended transsphenoidal surgery.

    PubMed

    Oshino, Satoru; Saitoh, Youichi; Yoshimine, Toshiki

    2010-06-01

    To examine the strength and tolerance of the fibrin glue sealant in a situation of extended transsphenoidal surgery. The withstand pressure of fibrin glue sealant was measured using a simple sellar reconstruction model. A 15-mm diameter hole at the bottom of a 51-cm high cylinder was covered with a Gore-Tex (Gore-Tex, Tokyo, Japan) sheet. A small plate was placed on the center for a brief fixation, and 3 mL of fibrin glue was applied over the entire bottom. Then water was gradually filled in five cylinders, and the water level at leakage was measured as withstand pressures at 10 minutes and 24 hours after sealant application. The stability of the sealant under pressures of 20 and 30 cm H(2)O for 12 hours was also examined. The median initial withstand pressure at 10 minutes was 32 cm H(2)O (n = 5), and was significantly increased to 47.5 cm H(2)O after 24 hours (n = 4). In four of five cylinders, fibrin glue sealants were stable against a pressure of 20 cm H(2)O for 12 hours and 30 cm H(2)O for the next 12 hours. The withstand pressure of simple fibrin glue sealant without other biological reactions could be estimated to be more than 20 cm H(2)O after application, and increased to more than 40 cm H(2)O after 24 hours. These data are practical for neurosurgeons to comprehend the strength and limit of fibrin glue sealant and suggests the importance to control the intracranial pressure to less than 20 cm H(2)O, especially for the first 12 to 24 hours. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. Results of fibrin glue application therapy in testicular hydrocele.

    PubMed

    Sirpa, A; Martti, A O

    1998-01-01

    Nine patients, mean age 55 years, with testicular hydroceles, were treated by aspiration and two-component fibrin glue injection. One patient was treated twice. The glue contains 70-110 mg fibrinogen and 500 IU human thrombin in 0.5- and 2-ml injections, respectively (Tisseel duo quick, Immune AB). The smaller glue volume was used in 4 cases and the larger volume in 6 cases. The average volume of hydrocele fluid was 77 (range 60-120) ml. Treatment caused no pain or discomfort other than puncture of the skin and no pain-relieving medication was required afterwards. In this series there were no infections but one conservatively treated hematoma. The hydrocele of that patient disappeared. Although the hydroceles recurred in 9 cases during the mean follow-up of 3.5 months, in 2 patients the hydroceles were clinically smaller than the original one and symptoms were milder subjectively. Our findings suggest that fibrin-adhesive glue is not sufficiently effective in treatment of testicular hydroceles.

  8. Fibrin glue as a hemostatic agent in hepatic and splenic trauma.

    PubMed

    Ochsner, M G; Maniscalco-Theberge, M E; Champion, H R

    1990-07-01

    Fibrin glue is a biologic hemostatic agent that coagulates and seals upon application. It is made by combining human fibrinogen concentrate with standard thrombin solutions containing calcium. Similar to epoxy glue, the two components are applied simultaneously in equal volumes resulting in an almost instantaneous formation of a coagulum. Fibrinogen concentrate is prepared in the blood bank from single donor plasma. Fibrin glue can be applied topically or injected into the parenchyma of solid organs. Twenty-six patients sustained hepatic or splenic trauma from May through August 1989--17 liver and nine splenic injuries. The glue was effective after one application in 21 patients and after a second in five. Hemostasis was achieved despite coagulopathy and thrombocytopenia in eight patients. There were no re-explorations for bleeding, and nine complications occurred in six patients. Our experience suggests fibrin glue is an effective, underutilized adjunctive hemostatic agent in trauma.

  9. Dynamics of glass-forming di-n-butyl phthalate as studied by NMR.

    PubMed

    Szcześniak, E; Głowinkowski, S; Suchański, W; Jurga, S

    1997-04-01

    Spin-lattice relaxation times T1 and nuclear Overhauser effect (NOE) enhancement factors for the individual ring carbons in di-n-butyl phthalate (DBF) show that the reorientational correlation function corresponding to the global dynamics in supercooled liquid can be described by a Davidson-Cole distribution. Measurements of proton spin-lattice relaxation times T1 and T1p, as well as 1H NMR spectra at temperatures below the glass transition temperature, Tg, reveal that the same distribution holds also for description of local dynamics in glassy DBF. The activation parameters of the motions detected are derived.

  10. PHARMACOKINETICS OF N-BUTYL ACETATE AND ITS METABOLITES IN MALE SPRAGUE DAWLEY RATS AFTER INTRAVENOUS ADMINISTRATION

    EPA Science Inventory

    FAMILY APPROACH PBPK MODELING OF N-BUTYL ACETATE AND ITS METABOLITES IN MALE RATS
    P.J. Deisinger1, J.G. Teeguarden2, H.A. Barton3, J.C. English1, W.D. Faber4, T.R. Tyler5, M.I. Banton6, M.E. Andersen7. 1Health & Environ. Laboratories., Eastman Kodak Company, Rochester, NY, USA...

  11. Does fibrin glue reduce lymph leakage (pleural effusion) after extended esophagectomy? Prospective randomized clinical trial.

    PubMed

    Tachibana, Mitsuo; Kinugasa, Shoichi; Yoshimura, Hiroshi; Dhar, Dipok Kumar; Ueda, Shuhei; Fujii, Toshiyuki; Kohno, Hitoshi; Nagasue, Naofumi

    2003-07-01

    Fibrin glue has been shown to be effective in improving postoperative chylothorax following various thoracic procedures and in reducing lymphorrhea after axillary dissection. It is unknown, however, whether fibrin glue is effective in reducing lymph leakage (pleural effusion) after esophagectomy. A series of 43 consecutive patients with thoracic esophageal cancer who underwent extended esophagectomy were prospectively randomized to two groups: group A (n = 21), in whom 3 ml of fibrin glue was applied to the dissected mediastinum; and group B (n = 22), in whom fibrin glue was not applied. The time of drain removal and the volume of the thoracic drainage were compared. All data were expressed as the mean +/- standard deviation. There were no significant differences in the clinicopathologic characteristics between the two groups. None of the patients developed chylothorax or died during their hospital stay. The daily volume from the thoracic drain (457 +/- 273 ml) was significantly (p < 0.05) larger on postoperative day (POD) 1 in group A than in group B (298 +/- 158 ml) and tended to be larger (p < 0.10) on PODs 4 and 6 in group A than in group B. The cumulative drainage volume was significantly (p < 0.05) larger on PODs 4 to 6 and POD 9, and it tended to be larger (p < 0.10) on PODs 1, 3, 7, 8, 10, and 11 in group A than in group B, suggesting that the cumulative drainage volume in group A was consistently larger than that in group B. The cumulative numbers of patients with a drain remaining in place were not significantly different for the two groups (p = 0.4683). Three patients in group A, however, had prolonged insertion (> 20 days) of the chest tube. There were no significant differences in the incidence of postoperative chest-related complications. No patients in group A developed viral infectious disease during the long-term follow-up. Application of fibrin glue to the dissected mediastinum seems to induce postoperative lymph leakage and thus be responsible

  12. Cyanoacrylate tissue adhesives - effective securement technique for intravascular catheters: in vitro testing of safety and feasibility.

    PubMed

    Simonova, G; Rickard, C M; Dunster, K R; Smyth, D J; McMillan, D; Fraser, J F

    2012-05-01

    Partial or complete dislodgement of intravascular catheters remains a significant problem in hospitals despite current securement methods. Cyanoacrylate tissue adhesives (TA) are used to close skin wounds as an alternative to sutures. These adhesives have high mechanical strength and can remain in situ for several days. This study investigated in vitro use of TAs in securing intravascular catheters (IVC). We compared two adhesives for interaction with IVC material, comparing skin glues with current securement methods in terms of their ability to prevent IVC dislodgement and inhibit microbial growth. Two TAs (Dermabond, Ethicon Inc. and Histoacryl, B. Braun) and three removal agents (Remove™, paraffin and acetone) were tested for interaction with IVC material by use of tensile testing. TAs were also compared against two polyurethane (standard and bordered) dressings (Tegaderm™ 1624 and 1633, 3M Australia Pty Ltd) and an external stabilisation device (Statlock, Bard Medical, Covington) against control (unsecured IVCs) for ability to prevent pull-out of 16 G peripheral IVCs from newborn fresh porcine skin. Agar media containing pH-sensitive dye was used to assess antimicrobial properties of TAs and polyurethane dressings to inhibit growth of Staphylococcus aureus and Staphylococcus epidermidis. Neither TA weakened the IVCs (P >0.05). Of removal agents, only acetone was associated with a significant decrease in IVC strength (P <0.05). Both TAs and Statlock significantly increased the pull-out force (P <0.01). TA was quick and easy to apply to IVCs, with no irritation or skin damage noted on removal and no bacterial colony growth under either TA.

  13. A protocol for the production of gliadin-cyanoacrylate nanoparticles for hydrophilic coating

    USDA-ARS?s Scientific Manuscript database

    This article presents a protocol for the production of protein-based nanoparticles that change the hydrophobic surface to hydrophilic by a simple spray coating. These nanoparticles are produced by the polymerization reaction of alkyl cyanoacrylate on the surface of cereal protein (gliadin) molecules...

  14. Histopathological effects of fibrin glue on penile fracture in a rat model.

    PubMed

    Tasdemir, Cemal; Samdanci, Emine T; Turtay, Muhammet G; Firat, Cemal; Oguzturk, Hakan; Ozdemir, Hulya

    2011-12-01

    To evaluate both histopathological effects and potential clinical application of fibrin glue on the penile cavernosal tissue. Experimental penile fracture was formed by incising from the proximal dorsal side of the penis in 32 Wistar Albino rats. The rats were randomly assigned to four main groups of eight animals each. In the control group, the incision was not repaired and it was left to secondary healing. In the primary repair group, the incision was primarily repaired. In the fibrin glue group, glue was applied only to the incision. In the final group, fibrin glue was applied to the incision following primary repair. Three weeks later, penectomy tissue was examined histopathologically. When the control group was compared with primary repair+fibrin glue group, the differences in cavernous tissue healing with fibrosis and inflammation were statistically significant (p = 0.04 and 0.01, respectively). The primary repair+fibrin glue group, showed the best cavernous healing with fibrosis observed in only one rat. . There was no significant difference between the control group and the other groups according to cavernous tissue healing with fibrosis and inflammation (p = 0.11 and 0.12). Hyperemia was observed in the all groups of rats. Fibrin glue can be used in cavernoseal surgeries due to its adhesive and potentially anti-inflammatory features.

  15. Patient-performed pinnaplasty using industrial nail glue.

    PubMed

    Chadha, Priyanka; Bast, Florian

    2017-02-01

    Malformations of the pinna occur in around 2-5% of all newborns. Prominent ears in childhood can be a source of psychological distress and lead to bullying and social exclusion. We present the case of a 14-year-old girl who inflicted chronic, non-healing wounds in the post auricular area bilaterally after attempting to glue back her ears with industrial strength glue. To our knowledge, this is the first case of its kind to be published. Copyright © 2016. Published by Elsevier B.V.

  16. Effectiveness of Fibrin Glue in Adherence of Skin Graft.

    PubMed

    Reddy, Konda Sireesha; Chittoria, Ravi Kumar; Babu, Preethitha; Marimuthu, Senthil Kumaran; Kumar, Sudhanva Hemanth; Subbarayan, Elan Kumar; Chavan, Vinayak; Mohapatra, Devi Prasad; Sivakumar, Dinesh Kumar; Friji, M T

    2017-01-01

    Graft fixation is important for graft take. Fibrin glue has been proposed as an ideal material, because of its human origin and it provides firm adhesion in seconds or minutes. To evaluate the efficiency of fibrin glue, in increasing the take of skin graft. Assessment includes surgical time taken for graft fixation, haematoma/seroma formation, engraftment and wound closure by day 14. The study is an observational prospective study conducted in the Department of Plastic Surgery, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, from January 2016 to June 2016. Sixteen patients who underwent split skin grafting were assessed during the study period. Fibrin glue was used on the recipient bed before grafting. Better haemostasis and graft adhesion, with a significant reduction of surgical time, were noted. The safety profile of fibrin glue was excellent as indicated by the lack of any related serious adverse experiences. These findings demonstrate that it is safe and effective for attachment of skin grafts, with outcomes at least as good as conventional methods.

  17. Effect of collagen sponge and fibrin glue on bone repair

    PubMed Central

    SANTOS, Thiago de Santana; ABUNA, Rodrigo Paolo Flores; de ALMEIDA, Adriana Luisa Gonçalves; BELOTI, Marcio Mateus; ROSA, Adalberto Luiz

    2015-01-01

    ABSTRACT The ability of hemostatic agents to promote bone repair has been investigated using in vitro and in vivo models but, up to now, the results are inconclusive. Objective In this context, the aim of this study was to compare the potential of bone repair of collagen sponge with fibrin glue in a rat calvarial defect model. Material and Methods Defects of 5 mm in diameter were created in rat calvariae and treated with either collagen sponge or fibrin glue; untreated defects were used as control. At 4 and 8 weeks, histological analysis and micro-CT-based histomorphometry were carried out and data were compared by two-way ANOVA followed by Student-Newman-Keuls test when appropriated (p≤0.05). Results Three-dimensional reconstructions showed increased bone formation in defects treated with either collagen sponge or fibrin glue compared with untreated defects, which was confirmed by the histological analysis. Morphometric parameters indicated the progression of bone formation from 4 to 8 weeks. Additionally, fibrin glue displayed slightly higher bone formation rate when compared with collagen sponge. Conclusion Our results have shown the benefits of using collagen sponge and fibrin glue to promote new bone formation in rat calvarial bone defects, the latter being discreetly more advantageous. PMID:26814464

  18. Dynamics of spider glue adhesion: effect of surface energy and contact area

    NASA Astrophysics Data System (ADS)

    Amarpuri, Gaurav; Chen, Yizhou; Blackledge, Todd; Dhinojwala, Ali

    Spider glue is a unique biological adhesive which is humidity responsive such that the adhesion continues to increase upto 100% relative humidity (RH) for some species. This is unlike synthetic adhesives that significantly drop in adhesion with an increase in humidity. However, most of adhesion data reported in literature have used clean hydrophilic glass substrate, unlike the hydrophobic, and charged insect cuticle surface that adheres to spider glue in nature. Previously, we have reported that the spider glue viscosity changes over five orders of magnitude with humidity. Here, we vary the surface energy and surface charge of the substrate to test the change in Larnioides cornutus spider glue adhesion with humidity. We find that an increase in both surface energy and surface charge density increases the droplet spreading and there exists an optimum droplet contact area where adhesion is maximized. Moreover, spider glue droplets act as reusable adhesive for low energy hydrophobic surface at the optimum humidity. These results explain why certain prey are caught more efficiently by spiders in their habitat. The mechanism by which spider species tune its glue adhesion for local prey capture can inspire new generation smart adhesives.

  19. Evaluation of a cyanoacrylate dressing to manage peristomal skin alterations under ostomy skin barrier wafers.

    PubMed

    Milne, Catherine T; Saucier, Darlene; Trevellini, Chenel; Smith, Juliet

    2011-01-01

    Peristomal skin alterations under ostomy barrier wafers are a commonly reported problem. While a number of interventions to manage this issue have been reported, the use of a topically applied cyanoacrylate has received little attention. This case series describes the use of a topical cyanoacrylate for the management of peristomal skin alterations in persons living with an ostomy. Using a convenience sample, the topical cyanoacrylate dressing was applied to 11 patients with peristomal skin disruption under ostomy wafers in acute care and outpatient settings. The causes of barrier function interruption were also addressed to enhance outcomes. Patients were assessed for wound discomfort using a Likert Scale, time to healing, and number of appliance changes. Patient satisfaction was also examined. Average reported discomfort levels were 9.5 out of 10 at the initial peristomal irritation assessment visit decreased to 3.5 at the first wafer change and were absent by the second wafer change. Wafers had increasing wear time between changes in both settings with acute care patients responding faster. Epidermal resurfacing occurred within 10.2 days in outpatients and within 7 days in acute care patients. Because of the skin sealant action of this dressing, immediate adherence of the wafer was reported at all pouch changes.

  20. Nonlinear temperature dependence of glue-induced birefringence in polarization maintaining FBG sensors

    NASA Astrophysics Data System (ADS)

    Hopf, Barbara; Koch, Alexander W.; Roths, Johannes

    2016-05-01

    Glue-induced stresses decrease the accuracy of surface-mounted fiber Bragg gratings (FBG). Significant temperature dependent glue-induced birefringence was verified when a thermally cured epoxy-based bonding technique had been used. Determining the peak separation of two azimuthally aligned FBGs in PM fibers combined with a polarization resolved measurement set-up in a temperature range between -30°C and 150°C revealed high glue-induced stresses at low temperatures. Peak separations of about 60 pm and a nonlinear temperature dependence of the glue-induced birefringence due to stress relaxation processes and a visco-elastic behavior of the used adhesive have been shown.

  1. Comparison of the Effect of Addition of Cyanoacrylate, Epoxy Resin, and Gum Arabic on Surface Hardness of Die Stone.

    PubMed

    Tripathi, Arvind; Gupta, Ashutosh; Bagchi, Soumyojeet; Mishra, Lallan; Gautam, Abhina; Madhok, Riti

    2016-04-01

    To observe the effects of incorporating cyanoacrylate, epoxy resins, and gum arabic on the abrasion resistance of type IV gypsum die materials. Forty specimens were prepared and divided into four groups (10 specimens in each group), namely group A (control), group B (die stone mixed with cyanoacrylate), group C (die stone mixed with epoxy resin), group D (die stone mixed with gum arabic). All the specimens were subjected to abrasion testing, wear volume analysis, Fourier transform infrared spectroscopy (FT-IR), and scanning electron microscope (SEM) analysis. Abrasion testing showed maximum wear in the control group and minimum wear in the gum arabic group. Intergroup differences were statistically significant (p < 0.001). The largest mean difference was between control and gum arabic. The lowest was between cyanoacrylate and the control group. The mean wear volume was lowest in the gum arabic group (4.23 mm(3) ) and highest in the control group (6.78 mm(3) ). The FT-IR graphs of the gum arabic models showed the presence of CH2 , which is responsible for its binding activity. SEM revealed that the irregular particles of gum arabic display an interlocking arrangement. This jigsaw puzzle pattern results in stronger physical bond formation. Observations from this study showed that the addition of gum arabic increases resistance to abrasion in type IV gypsum. Cyanoacrylates are good adhesives as well, but a major drawback is that they have very low resistance to chemical action with water and physical actions such as sunlight. Epoxy resins are powerful adhesives, but they attain their full efficiency when cured with heat. Cyanoacrylate and epoxy resin displayed poor physical bonding, primarily because of inhomogeneity. © 2015 by the American College of Prosthodontists.

  2. Evaluation of Lumicyano™ cyanoacrylate fuming process for the development of latent fingermarks on plastic carrier bags by means of a pseudo operational comparative trial.

    PubMed

    Farrugia, Kevin J; Deacon, Paul; Fraser, Joanna

    2014-03-01

    There are a number of studies discussing recent developments of a one-step fluorescent cyanoacrylate process. This study is a pseudo operational trial to compare an example of a one-step fluorescent cyanoacrylate product, Lumicyano™, with the two recommended techniques for plastic carrier bags; cyanoacrylate fuming followed by basic yellow 40 (BY40) dyeing and powder suspensions. 100 plastic carrier bags were collected from the place of work and the items were treated as found without any additional fingermark deposition. The bags were split into three and after treatment with the three techniques a comparable number of fingermarks were detected by each technique (average of 300 fingermarks). The items treated with Lumicyano™ were sequentially processed with BY40 and an additional 43 new fingermarks were detected. Lumicyano™ appears to be a suitable technique for the development of fingermarks on plastic carrier bags and it can help save lab space and time as it does not require dyeing or drying procedures. Furthermore, contrary to other one-step cyanoacrylate products, existing cyanoacrylate cabinets do not require any modification for the treatment of articles with Lumicyano™. To date, there is little peer reviewed articles in the literature on trials related to Lumicyano™ and this study aims to contribute to fill this gap. © 2013.

  3. Fibrin Glue Used as an Adhesive Agent in CNS Tissues

    PubMed Central

    Cheng, Henrich; Almström, Susanne; Olson, Lars

    1994-01-01

    One of the limitations of many bridging experiments in neural transplantation is that the CNS tissues cannot be sutured. Fibrin glue is a two-component system derived from whole blood which, when mixed, reproduces the final stage of blood coagulation and solidifies. Many experimental studies of humans and animals show that fibrin glue repair of peripheral nerves is almost equivalent to microsurgical sutures. In this study, we attempted to extend its use to CNS tissues and transplants. Two techniques were tried: (1) Bilateral parietal knife cuts were performed by stereotaxic technique in six rats. Fibrin glue was applied in the right-side cortical lesion. Immunohistochemistry using antisera to tyrosine hydroxylase (TH), glial fibrillary acidic protein (GFAP), laminin and neurofilament (NF) was essentially similar between the control and treatment groups. The immunoreactivity of each marker revealed no significant differences between the two groups on days 1, 7 and 30. There was no difference in terms of gliosis or microvascular proliferation. (2) Embryonic day 16 fetal locus coeruleus was grafted together with E16 cortex to the anterior chamber of sympathectomized eyes. In the six eyes of the glue treatment group, the parietal cortical piece and the locus coeruleus piece were joined together before grafting by immersing them in the solution of fibrin glue. In the eight eyes of the control group, pieces of parietal cortex and locus coeruleus were introduced individually and approximated by gently pressing the cornea. The sizes of double grafts showed no significant difference between groups during six weeks postgrafting. The immunohistochemical pictures using antisera against TH, GFAP and laminin were similar in both groups. Catecholaminergic fibers from the grafted locus coeruleus were found bridging over into the parietal cortical piece in both the control and treatment groups. There was no significant difference in TH-positive nerve fiber density between tissue

  4. Di-tert-butyl-chlorido(N,N-dibenzyl-dithio-carbamato)tin(IV).

    PubMed

    Abdul Muthalib, Amirah Faizah; Baba, Ibrahim; Mohamed Tahir, Mohamed Ibrahim; Tiekink, Edward R T

    2011-02-26

    The Sn(IV) atom in the title diorganotin dithio-carbamate, [Sn(C(4)H(9))(2)(C(15)H(14)NS(2))Cl], is penta-coordinated by an asymmetrically coordinating dithio-carbamate ligand, a Cl atom and two C atoms of the Sn-bound tert-butyl groups. The resulting C(2)ClS(2) donor set defines a coordination geometry inter-mediate between square pyramidal and trigonal bipyramidal with a slight tendency towards the former.

  5. Enhanced cometabolic degradation of methyl tert-butyl ether by a Pseudomonas sp. strain grown on n-pentane

    NASA Astrophysics Data System (ADS)

    Li, S. S.; Wang, S.; Yan, W.

    2016-08-01

    When methyl tert-butyl ether (MTBE) is added as oxygenates it increases the octane number and decreases the release of nitric oxide from the incomplete combustion of reformulated gasoline. The extensive use of MTBE allowed it to be detectable as a pollutant in both ground-level and underground water worldwide. The present study focuses on the isolation and characterization of MTB-degrading microorganisms by cometabolism based on the results of growth on different carbon sources. It also focuses on the kinetic analysis and the continuous degradation of MTBE. A bacterial strain WL1 that can grow on both n-alkanes (C5-C8) and aromatics was isolated and named Pseudomonas sp. WL1 according to the 16S rDNA sequencing analysis. Strain WL1 could cometabolically degrade MTBE in the presence of n-alkanes with a desirable degradation rate. Diverse n-alkanes with different lengths of carbon chains showed significant influence on the degradation rate of MTBE and accumulation of tert-butyl alcohol (TBA). When strain WL1 cometabolically degraded MTBE in the presence of n-pentane, higher MTBE-degrading rate and lower TBA-accumulation were observed (Vmax = 38.1 nmol/min/mgprotei, Ks = 6.8 mmol/L). In the continuous degrading experiment, the removal efficiency of MTBE by Pseudomonas sp. WL1 did not show any obvious decrease after five subsequent additions.

  6. Commissioning of the pair spectrometer of the GlueX experiment

    DOE PAGES

    Somov, A.; Tolstukhin, I.; Somov, S. V.; ...

    2017-03-07

    The main goal of the pair spectrometer of the GlueX experiment at Jefferson Lab is to determine the photon beam flux and to measure beam polarization. Here, we present the design of the pair spectrometer and the performance results during the first commissioning runs of the GlueX experiment.

  7. Axillary lymphadenectomy for breast cancer in elderly patients and fibrin glue

    PubMed Central

    2013-01-01

    Background Axillary lymphadenectomy or sentinel biopsy is integral part of breast cancer treatment, yet seroma formation occurs in 15-85% of cases. Among methods employed to reduce seroma magnitude and duration, fibrin glue has been proposed in numerous studies with controversial results. Methods Thirty patients over 60 years underwent quadrantectomy or mastectomy with level I/II axillary lymphadenectomy; a suction drain was fitted in all patients. Fibrin glue spray were applied to the axillary fossa in 15 patients; the other 15 patients were treated with harmonic scalpel. Results Suction drainage was removed between post-operative Days 3 and 4. Seroma magnitude and duration were not significant in patients receiving fibrin glue compared with the harmonic scalpel group. Conclusions Use of fibrin glue does not always prevent seroma formation, but can reduce seroma magnitude, duration and necessary evacuative punctures. PMID:24266959

  8. Closure of ascites leaks with fibrin glue injection in patients with end-stage liver disease.

    PubMed

    Sadik, Karim W; Laibstain, Sarah; Northup, Patrick G; Kashmer, David; Schmitt, Timothy M; Bonatti, Hugo J R

    2011-09-01

    Ascites leaks (AL) in patients with end-stage liver disease (ESLD) are associated with significant morbidity and mortality regardless if they are medically or surgically managed. In a pilot study, 14 ESLD patients with AL underwent treatment with fibrin glue injection around the leak after failing conservative therapy. The end point of this study was the cessation of AL in the short term and the maintenance of a leak-free abdomen in the long term, allowing for medical optimization of the patients. Median age of the 10 men and 4 women was 50 (range 26-67) years. Underlying ESLDs were chronic hepatitis C (n=5), alcoholic LD (n=2), cryptogenic cirrhosis (n=2), and miscellaneous (n=5). There were six leaking incisions posthernia repair (three umbilical and three inguinal), two leaking/ruptured umbilical hernias, four leaking paracentesis sites, one leaking Jackson-Pratt (JP) drain canal, and one leaking laparoscopic trocar site. Average AL volume per day was 1000 (range 400-2000) mL. All leaks were immediately resolved with a 3-5 mL fibrin glue injection. Five recurred and required a second injection (four within 24 hours). Mental status improved in 7 patients (West Haven Criteria: grade II to I [n=6], grade III to I [n=1]). Median model of end-stage liver disease scores improved from 23 (range 8-33) to 20 (range 14-26). There were no infections, bleeds, or other injection-related complications. Average follow-up for these patients was 441.6 days (range 2-852). Five patients underwent liver transplant (LT) median 15 (range 4-270) days postinjection; 2 of them died. Another 3 patients died (2 from sepsis and 1 from metastatic cancer). Fibrin glue injection for the control of AL is a simple and safe bedside procedure that quickly controls AL, allowing for patient recovery in anticipation of further care.

  9. The GlueX Experiment: First Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fanelli, Cristiano

    GlueX is a nuclear physics experiment located at the Thomas Jefferson National Accelerator Facility designed to study and understand the nature of confinement in QCD by mapping the spectrum of exotic mesons. The experiment will be able to probe new areas by using photoproduction, i.e. the scattering on nucleon of ~9 GeV linearly polarized photons derived from the recently upgraded CEBAF with a 12 GeV electron beam. Spring 2016 has been characterized by a continued detector commissioning and initial running at the full design energy. The current status of the GlueX detector performance and data collection will be discussed, withmore » a brief overview of first physics results, future run plans, and long term upgrades.« less

  10. Clinical experience with fibrin glue in cardiac surgery.

    PubMed

    Köveker, G; de Vivie, E R; Hellberg, K D

    1981-10-01

    Cardiac surgery is often associated with hemostatic abnormalities leading to severe bleeding. Special problems are to be expected, if prosthetic material has to be implanted. Preclotting of Dacron prostheses with blood is well established but failures are sometimes encountered. Several years ago a new hemostatic sealing system (fibrin glue) was introduced into therapy. Since 1978 fibrin glue has been applied in 176 patients. The indications were: 1. sealing of woven Dacron prostheses, 2. bleeding from suture-holes (Gore-Tex), 3. diffuse myocardial bleeding and 4. prevention of kinking of coronary artery grafts. In 32 patients with an aortoventriculoplasty operation using Dacron the "blood preclotting" and "fibrin sealing" methods were compared. In the fibrin glue group there was a significant reduction in postoperative blood loss as well as a shortening of the operation time (period of protamin administration to skin closure). No fibrinolytic dissolution of the fibrin layer on the prostheses was observed.

  11. Fibrin glue as interposition graft for tarsal coalition.

    PubMed

    Weatherall, Justin M; Price, Andrew E

    2013-01-01

    We describe a surgical technique and report outcomes for fibrin glue interposition after resection of a tarsal condition. An institutional review board--approved retrospective review of all pediatric patients with a tarsal coalition managed with resection was conducted between January 2002 and July 2010 by a single surgeon. All coalitions were resected with interposition of fibrin glue. Patients were evaluated for postoperative complications, pain, weight-bearing status, return to sports, and ankle and subtalar range of motion. Six feet without a coalition were used as a control group. Nine patients (12 feet) were identified with mean follow-up of 2.1 years (range, 7-72 months). Pre-operative complaints were predominantly foot and ankle pain. Patients also reported flatfeet and recurrent ankle sprains. There were no reported postoperative complications. All 9 patients were weight-bearing as tolerated and returned to sports by 6 months. Fibrin glue is a safe and reliable alternative to tissue grafts for interposition after resection of a tarsal coalition.

  12. Evidence from Multiple Species that Spider Silk Glue Component ASG2 is a Spidroin

    PubMed Central

    Collin, Matthew A.; Clarke, Thomas H.; Ayoub, Nadia A.; Hayashi, Cheryl Y.

    2016-01-01

    Spiders in the superfamily Araneoidea produce viscous glue from aggregate silk glands. Aggregate glue coats prey-capture threads and hampers the escape of prey from webs, thereby increasing the foraging success of spiders. cDNAs for Aggregate Spider Glue 1 (ASG1) and 2 (ASG2) have been previously described from the golden orb-weaver, Nephila clavipes, and Western black widow, Latrodectus hesperus. To further investigate aggregate glues, we assembled ASG1 and ASG2 from genomic target capture libraries constructed from three species of cob-web weavers and three species of orb-web weavers, all araneoids. We show that ASG1 is unlikely to be a glue, but rather is part of a widespread arthropod gene family, the peritrophic matrix proteins. For ASG2, we demonstrate its remarkable architectural and sequence similarities to spider silk fibroins, indicating that ASG2 is a member of the spidroin gene family. Thus, spidroins have diversified into glues in addition to task-specific, high performance fibers. PMID:26875681

  13. Quantifying Dimer and Trimer Formation by Tri- n -butyl Phosphates in n -Dodecane: Molecular Dynamics Simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vo, Quynh N.; Dang, Liem X.; Nilsson, Mikael

    2016-07-21

    Tri-n-butyl phosphate (TBP), a representative of neutral organophosphorous ligands, is an important extractant used in solvent extraction process for the recovery of uranium and plutonium from spent nuclear fuel. Microscopic pictures of TBP isomerism and its behavior in n-dodecane diluent were investigated utilizing MD simulations with previously optimized force field parameters for TBP and n-dodecane. Potential Mean Force (PMF) calculations on a single TBP molecule show seven probable TBP isomers. Radial Distribution Functions (RDF) of TBP suggests the existence of TBP trimers at high TBP concentrations in addition to dimers. 2D PMF calculations were performed to determine the angle andmore » distance criteria for TBP trimers. The dimerization and trimerization constants of TBP in n-dodecane were obtained and match our own experimental values using FTIR technique. The new insights into the conformational behaviors of TBP molecule as a monomer and as part of an aggregate could greatly aid the understanding of the complexation between TBP and metal ions in solvent extraction system. The U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences and Biosciences funded the work performed by LXD.« less

  14. Fibrin glue as a protective tool for microanastomoses in limb reconstructive surgery

    PubMed Central

    Langer, Stefan; Schildhauer, Thomas A.; Dudda, Marcel; Sauber, Jeannine; Spindler, Nick

    2015-01-01

    Aim: Fibrin glue becomes a more and more routinely used tool for stabilization of microanastomoses and nerve repair. This paper summarizes the technical properties and advantages of its use in a wide variety of microsurgical contexts, and includes an exemplary limb reconstructive case. Patients and methods: A total of 131 patients who had undergone elective and emergency microsurgery mainly of the limbs were retrospectively analyzed, as was the use of free flaps. Results: The use of fibrin glue allows for proper positioning of anastomoses and repaired nerves. No torsion of the pedicle could be seen. The flap survival rated >94%. The fibrin glue could stay in place in >99%. In the rare case of revision, the fibrin glue could easily be removed without damaging the region of the microanastomosis. Conclusion: Fibrin glue should not be used to repair insufficient, i.e., leaking anastomoses, but it does protect the site of anastomosis from tissue and fluid pressure. It prevents the pedickle from torsion and its use facilitates relocation of the microanastomoses in cases of revision surgery. PMID:26759762

  15. Fibrin glue as a protective tool for microanastomoses in limb reconstructive surgery.

    PubMed

    Langer, Stefan; Schildhauer, Thomas A; Dudda, Marcel; Sauber, Jeannine; Spindler, Nick

    2015-01-01

    Fibrin glue becomes a more and more routinely used tool for stabilization of microanastomoses and nerve repair. This paper summarizes the technical properties and advantages of its use in a wide variety of microsurgical contexts, and includes an exemplary limb reconstructive case. A total of 131 patients who had undergone elective and emergency microsurgery mainly of the limbs were retrospectively analyzed, as was the use of free flaps. The use of fibrin glue allows for proper positioning of anastomoses and repaired nerves. No torsion of the pedicle could be seen. The flap survival rated >94%. The fibrin glue could stay in place in >99%. In the rare case of revision, the fibrin glue could easily be removed without damaging the region of the microanastomosis. Fibrin glue should not be used to repair insufficient, i.e., leaking anastomoses, but it does protect the site of anastomosis from tissue and fluid pressure. It prevents the pedickle from torsion and its use facilitates relocation of the microanastomoses in cases of revision surgery.

  16. A comparative study of the effects of 4-META/MMA-TBB resin and cyanoacrylate on wound healing of skin defects.

    PubMed

    Kidokoro, Ryo; Nakajima, Kei; Kobayashi, Fumitaka; Takeda, Yukihiro; Matsuzaka, Kenichi; Katakura, Akira; Inoue, Takashi

    2016-01-01

    The purpose of this study was to investigate the healing process of wounded skin following the application of cyanoacrylate or a 4-(2-methacryloxyethyl) trimellitic anhydride/methyl methacrylate-tributylborane resin (4-META resin). Those materials were applied to skin wound areas in rats, and the regenerating tissues were biopsied and examined at days 1, 3, 5, 7, and 14. Paraffin-embedded specimens were sectioned and stained with hematoxylin and eosin or with Azan-Mallory stain. Sections were also immunohistochemically stained with Pan-cytokeratin and CD68 antibodies. In cyanoacrylate-treated wounds, CD68-positive cells were observed in the connective tissue and their number increased up to day 5. The wound surface was completely covered by epithelial tissue at day 14. In 4-META resin-treated wounds, CD68-positive cells appeared in the soft-tissue hybrid layer (STHL) and epithelial tissue had migrated under the STHL by day 5. The wound surface was completely covered by epithelial tissue at day 7. CD68-positive cells were distributed over the entire area of the cyanoacrylate-treated wounds, but accumulated under the STHL in the 4-META resin-treated wounds. In conclusion, the results suggest that covering skin defects with a 4-META resin is an effective strategy to promote wound healing compared to cyanoacrylate. © 2015 Wiley Periodicals, Inc.

  17. Control of DNA hybridization by photoswitchable molecular glue.

    PubMed

    Dohno, Chikara; Nakatani, Kazuhiko

    2011-12-01

    Hybridization of DNA is one of the most intriguing events in molecular recognition and is essential for living matter to inherit life beyond generations. In addition to the function of DNA as genetic material, DNA hybridization is a key to control the function of DNA-based materials in nanoscience. Since the hybridization of two single stranded DNAs is a thermodynamically favorable process, dissociation of the once formed DNA duplex is normally unattainable under isothermal conditions. As the progress of DNA-based nanoscience, methodology to control the DNA hybridization process has become increasingly important. Besides many reports using the chemically modified DNA for the regulation of hybridization, we focused our attention on the use of a small ligand as the molecular glue for the DNA. In 2001, we reported the first designed molecule that strongly and specifically bound to the mismatched base pairs in double stranded DNA. Further studies on the mismatch binding molecules provided us a key discovery of a novel mode of the binding of a mismatch binding ligand that induced the base flipping. With these findings we proposed the concept of molecular glue for DNA for the unidirectional control of DNA hybridization and, eventually photoswitchable molecular glue for DNA, which enabled the bidirectional control of hybridization under photoirradiation. In this tutorial review, we describe in detail how we integrated the mismatch binding ligand into photoswitchable molecular glue for DNA, and the application and perspective in DNA-based nanoscience.

  18. The properties of gelatin-poly (gamma-glutamic acid) hydrogels as biological glues.

    PubMed

    Hsu, Shan-Hui; Lin, Chen-Huan

    2007-01-01

    The influence of the molecular weight and the type of gelatin (A or B), as well as the molecular weight of poly (gamma-glutamic acid) (gamma-PGA), on the properties of gelatin/gamma-PGA mixed bioadhesives were studied. The gelation of the system was enhanced by a crosslinker, 1-(3-dimethylaminopropyl)-3-(ethylcarbodiimide) hydrochloride (EDC). The gelation time of the bioadhesives was analyzed using rheological measurements. The results indicated that the type of gelatin was a critical factor in determining the gelation time of the biological glues. The mixed glues had greater bonding strength and smaller gelation times as the molecular weight of gamma-PGA or gelatin increased. The swelling ratio decreased and the denaturation temperature increased upon raising the EDC concentration, indicating a greater degree of crosslinking at higher EDC concentrations. The mixed glues crosslinked with various concentrations of EDC (1.7-2.5%) showed no cytotoxicity to fibroblasts. In addition, no significant inflammatory response was observed in the rat subcutaneous implantation. The bioadhesives based on gelatin/gamma-PGA remained at the site for 7 days while the fibrin glue had almost completely degraded. By choosing the appropriate gelatin type and higher molecular weight gamma-PGA in the mixtures, the gelatin/gamma-PGA biological glues could serve as soft tissue adhesives. Rheological characterization was essential in the evaluation of biological glues.

  19. Comparison of fibrin glue and Vicryl sutures in conjunctival autografting for pterygium surgery.

    PubMed

    Wang, Xiu; Zhang, Yan; Zhou, Lei; Wei, Ruihua; Dong, Lijie

    2017-01-01

    To compare clinical parameters and the tear levels of inflammatory cytokines between pterygium surgery using sutures or fibrin glue. Fifty-six patients with primary pterygium were divided into the suture group and the glue group, in which the autograft was secured with 10-0 Vicryl sutures and fibrin glue, respectively. A questionnaire, slit-lamp examination, Schirmer test, and visual acuity test were performed in all participants. Real-time quantitative PCR (q-PCR) was used to analyze the expression of genes in pterygium and healthy conjunctival tissues. Based on the qPCR results and literature reports, five inflammatory cytokines, including hepatocyte growth factor (HGF), fibroblast growth factor 2 (FGF2), transforming growth factor-β1 (TGF-β1), matrix metalloproteinase 2 (MMP2), and tumor necrosis factor-α (TNF-α), were selected, and their protein levels were measured with enzyme-linked immunosorbent assay (ELISA) in patient tears before surgery as well as at postoperative day 1, 7, and 30. There are 28 patients in either the suture or the glue group. The average duration of surgery was 20.17 ± 3.23 min for the glue group and 32.42 ± 4.47 min for the suture group (p = 0.000). Visual acuity in both groups was improved (p = 0.002) after the surgical procedures. There were more symptoms in the suture group than in the glue group at postoperative day 7 (p = 0.002). Postoperative symptoms disappeared in both groups at 1 month after surgery. Recurrence was observed in one case in the glue group and in two cases in the suture group at the 6 month postoperative follow-up (p = 0.714). In comparison to the preoperative levels (4.33 ± 0.43 ng/ml for the suture group; 4.20 ± 0.26 ng/ml for the glue group), the levels of TNF-α in tears increased in the suture group (5.02 ± 0.49 ng/ml, p = 0.016) and decreased in the glue group (3.84 ± 0.35 ng/ml, p = 0.052) on postoperative day 1. The glue treatment induced higher HGF production (4.78 ± 1.25 ng/ml) than the suture

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi Haibin, E-mail: shihb@vip.sina.com; Yang Zhengqiang; Liu Sheng

    To evaluate the efficacy and safety of cyanoacrylate glue embolization in the treatment of severe arterioportal shunt (APS) presenting with hepatofugal portal venous flow in hepatocellular carcinoma (HCC) patients. Between July 2000 and January 2010, 27 HCC patients with severe APS presenting with hepatofugal portal venous flow underwent transarterial angiography and treatment. Among them, four patients were excluded from the study. Twelve patients underwent transarterial chemoperfusion and embolization of APS with cyanoacrylate glue between January 2006 and January 2010 (Emb group), and the other 11 patients undergoing only transarterial chemoperfusion without embolization of APS between July 2000 and December 2005more » served as a control group (non-Emb group). The change of APS, survival rates, and procedure related complications were analyzed. In the Emb group, APS was improved in all of the 12 patients after initial glue embolization; long-term APS improvement with hepatopetal portal flow was achieved in 80 % (8 of 10) patients who underwent follow-up angiography. Survival rates in the Emb group were 67 % at 6 months, 33 % at 1 year, and 8 % at 2 years, whereas those in the non-Emb group were 0 % at 6 months (P < 0.05). Median survival time in the Emb group was 275 days, which was longer than that of 107 days in the non-Emb group (P = 0.001). There were no major complications in both groups. The preliminary experience suggests that glue embolization may be an effective and safe therapy in the management of severe APS accompanied by HCC and also improve patient survival.« less

  1. Comprehensive Review of Tissue Adhesives.

    PubMed

    Jenkins, Lauren E; Davis, Loretta S

    2018-06-19

    Cyanoacrylates, also known as tissue adhesives or skin glues, are commonly used as sealants for lacerations and incisions and have found utility in excisional and cosmetic surgeries in both outpatient and operating room settings. To review the surgical literature on the utilities, advantages, disadvantages, and special uses of cyanoacrylates applicable to dermatology. PubMed was reviewed for relevant articles related to cyanoacrylates and their use in skin closures. Articles unrelated to cutaneous closures were excluded. Tissue adhesives polymerize to a water resistant, pliable film after application to approximated wound edges and have antibacterial properties. Adhesives slowly slough off as the wound heals, typically after 5 days. Compared with 5-0 nonabsorbable suture, adhesives provide similar tensile strength and similar patient and surgeon satisfaction. Although slightly more expensive than sutures, tissue adhesives obviate the need for wound dressings and suture removal. They do not perform as well as sutures for wounds under higher tension or in the setting of moisture and inadequate hemostasis. Cyanoacrylates serve as a safe and effective suture alternative in appropriate dermatologic surgeries and procedures.

  2. Glues Used in Airplane Parts

    NASA Technical Reports Server (NTRS)

    Allen, S W; Truax, T R

    1920-01-01

    This report was prepared for the National Advisory Committee for Aeronautics and presents the results of investigations conducted by the Forest Products Laboratory of the United States Forest Service on the manufacture, preparation, application, testing and physical properties of the different types of glues used in wood airplane parts.

  3. Augmenting pancreatic anastomosis during whipple operation with fibrin glue: a beneficial technical modification?

    PubMed

    Conaglen, Paul J; Collier, Neil A

    2014-04-01

    Various techniques have been described to try and reduce the rate of anastomotic leak following pancreaticoduodenectomy, which remains a challenge for pancreatic surgeons worldwide. We outline a technique to reinforce the pancreatic anastomosis with a double layer of fibrin glue between suture lines. Our technique for pancreatic anastomosis is described in detail. A review of consecutive pancreaticoduodenectomies by a single surgeon (NAC) since introduction of fibrin glue anastomosis reinforcement was compared with a historical control cohort performed by the same surgeon. Thirty-two consecutive pancreaticoduodenectomies were undertaken between March 2008 and March 2012 by a single surgeon, 30 patients had fibrin glue augmentation of the pancreatico-gastrostomy anastomosis. Median length of stay was 12 days. There were no pancreatic leaks or mortality since adopting fibrin glue for the pancreatic anastomosis; however; this single surgeon series is not large enough to provide statistical evidence of a difference since glue was adopted. Our results since the incorporation of this step in pancreaticoduodenectomy are encouraging. Selective use of glue is worthy of consideration in difficult cases, although confirmation of a reduction in pancreatic leak rate is not yet established, and we advocate a multi-institution randomized controlled trial to explore this. © 2013 The Authors. ANZ Journal of Surgery © 2013 Royal Australasian College of Surgeons.

  4. (N-Benzyl-N-ethyl-dithio-carbamato)di-tert-butyl-chloridotin(IV).

    PubMed

    Abdul Muthalib, Amirah Faizah; Baba, Ibrahim; Mohamed Tahir, Mohamed Ibrahim; Tiekink, Edward R T

    2011-02-26

    The Sn(IV) atom in the title diorganotin dithio-carbamate, [Sn(C(4)H(9))(2)Cl(C(10)H(12)NS(2))], is penta-coordinated by an asymmetrically coordinating dithio-carbamate ligand, a Cl and two C atoms of the Sn-bound tert-butyl groups. The resulting C(2)ClS(2) donor set defines a coordination geometry inter-mediate between square pyramidal and trigonal bipyramidal with a slight tendency towards the former. In the crystal structure, C-H⋯π contacts link centrosymmetrically related mol-ecules into dimeric aggregates.

  5. Fractionation of Poly(butyl methacrylate) by Molecular Topology Using Multidetector Thermal Field-Flow Fractionation.

    PubMed

    Greyling, Guilaume; Pasch, Harald

    2015-12-01

    Thermal field-flow fractionation (ThFFF) is an interesting alternative to column-based fractionation being able to address different molecular parameters including size and composition. Until today it has not been shown to be able to fractionate polymers of similar molar masses and chemical compositions by molecular topology. The present study demonstrates that poly(butyl methacrylates) with identical molar masses can be fractionated by ThFFF according to the topology of the butyl group. The influence of the solvent polarity on the thermal diffusion behavior of these polymers is presented and it is shown to have a significant influence on the fractionation of poly(n-butyl methacrylate) and poly(t-butyl methacrylate). Fractionation improves with increasing solvent polarity and solvent polarity may have a greater influence on fractionation than solvent viscosity. It is found that the thermal diffusion coefficient, D(T), as well as the hydrodynamic diameter, D(h), exhibit increasing trends with increasing solvent polarity. The solvent quality has a significant influence on the fractionation. It is found that cyclohexane, being a theta solvent for poly(t-butyl methacrylate) but not for poly(n-butyl methacrylate), significantly improves the fractionation of the samples by decreasing the diffusion rate of the former but not the latter. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Glue detection based on teaching points constraint and tracking model of pixel convolution

    NASA Astrophysics Data System (ADS)

    Geng, Lei; Ma, Xiao; Xiao, Zhitao; Wang, Wen

    2018-01-01

    On-line glue detection based on machine version is significant for rust protection and strengthening in car production. Shadow stripes caused by reflect light and unevenness of inside front cover of car reduce the accuracy of glue detection. In this paper, we propose an effective algorithm to distinguish the edges of the glue and shadow stripes. Teaching points are utilized to calculate slope between the two adjacent points. Then a tracking model based on pixel convolution along motion direction is designed to segment several local rectangular regions using distance. The distance is the height of rectangular region. The pixel convolution along the motion direction is proposed to extract edges of gules in local rectangular region. A dataset with different illumination and complexity shape stripes are used to evaluate proposed method, which include 500 thousand images captured from the camera of glue gun machine. Experimental results demonstrate that the proposed method can detect the edges of glue accurately. The shadow stripes are distinguished and removed effectively. Our method achieves the 99.9% accuracies for the image dataset.

  7. Tetra-μ3-iodido-tetra­kis­[(tri-n-butyl­phosphane-κP)copper(I)

    PubMed Central

    Klenk, Simon; Frey, Wolfgang; Bubrin, Martina; Laschat, Sabine

    2014-01-01

    The title complex, [Cu4I4(C12H27P)4], crystallizes with six mol­ecules in the unit cell and with three independent one-third mol­ecule fragments, completed by application of the relevant symmetry operators, in the asymmetric unit. The tetranuclear copper core shows a tetrahedral geometry (site symmetry 3..). The I atoms also form a tetra­hedron, with I⋯I distances of 4.471 (1) Å. Both tetra­hedra show an orientation similar to that of a pair of self-dual platonic bodies. The edges of the I-tetra­hedral structure are capped to the face centers of the Cu-tetra­hedron and vice versa. The Cuface⋯I distances are 2.18 Å (averaged) and the Iface⋯Cu distances are 0.78 Å (averaged). As a geometric consequence of these properties there are eight distorted trigonal–bipyramidal polyhedra evident, wherein each trigonal face builds up the equatorial site and the opposite Cu⋯I positions form the axial site. As expected, the n-butyl moieties are highly flexible, resulting in large elongations of their anisotropic displacement parameters. Some C atoms of the n-butyl groups were needed to fix alternative discrete disordered positions. PMID:24826086

  8. Minimizing Collateral Brain Injury Using a Protective Layer of Fibrin Glue: Technical Note.

    PubMed

    Basma, Jaafar; Latini, Francesco; Ryttlefors, Mats; Abuelem, Tarek; Krisht, Ali Fadl

    2015-12-01

    Neurosurgical procedures expose the brain surface to a constant risk of collateral injury. We describe a technique where the brain surface is covered with a protective layer of fibrin glue and discuss its advantages. A thin layer of fibrin glue was applied on the brain surface after its exposure in 34 patients who underwent different craniotomies for tumoral and vascular lesions. Data of 35 more patients who underwent standard microsurgical technique were collected as a control group. Cortical and pial injuries were evaluated using an intraoperative visual scale. Eventual abnormal signals at the early postoperative T2-weighted fluid-attenuated inversion recovery (T2FLAIR) magnetic resonance imaging (MRI) sequences were evaluated in oncological patients. Total pial injury was noted in 63% of cases where fibrin glue was not used. In cases where fibrin glue was applied, a significantly lower percentage of 26% (P < 0.01) had pial injuries. Only 9% had injuries in areas covered with fibrin glue (P < 0.0001). Early postoperative T2FLAIR MRI confirmed the differences of altered signal around the surgical field in the two populations. We propose beside an appropriate and careful microsurgical technique the possible use of fibrin glue as alternative, safe, and helpful protection during complex microsurgical dissections. Its intrinsic features allow the neurosurgeon to minimize the cortical manipulation preventing minor collateral brain injury. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Adhesive arachnoiditis after percutaneous fibrin glue treatment of a sacral meningeal cyst.

    PubMed

    Hayashi, Kazunori; Nagano, Junji; Hattori, Satoshi

    2014-06-01

    The authors present the case of a 64-year-old woman who was referred for severe sacral pain. She reported that her pain had been longstanding, and had greatly increased after percutaneous fibrin glue placement therapy for a sacral meningeal cyst 2 months earlier at a different hospital. An MRI scan obtained immediately after fibrin glue placement at that hospital suggested that fibrin glue had migrated superiorly into the subarachnoid space from the sacral cyst to the level of L-4. On admission to the authors' institution, physical examination demonstrated no abnormal findings except for perianal hypesthesia. An MRI study obtained at admission demonstrated a cystic lesion in the peridural space from the level of S-2 to S-4. Inhomogeneous intensity was identified in this region on T2-weighted images. Because the cauda equina and nerve roots appeared to be compressed by the lesion, total cyst excision was performed. The cyst cavity was filled with fluid that resembled CSF, plus gelatinous material. Histopathological examination revealed that the cyst wall was composed of hyaline connective tissue with some calcification. No nervous tissue or ganglion cells were found in the tissue. The gelatinous material was acellular, and appeared to be degenerated fibrin glue. Sacral pain persisted to some extent after surgery. The authors presumed that migrated fibrin glue caused the development of adhesive arachnoiditis. The risk of adhesive arachnoiditis should be considered when this therapy is planned. Communication between a cyst and the subarachnoid space should be confirmed to be sufficiently narrow to prevent the migration of injected fibrin glue.

  10. Spiritual and Religious Supports Part 8: Church G.L.U.E.

    ERIC Educational Resources Information Center

    Newman, Barbara J.

    2009-01-01

    CLC Network is an organization that partners with churches, schools, and families to help promote and build inclusive and interdependent communities for those with disabilities. This article describes CLC Network's most recent tool--a book entitled the G.L.U.E. Training Manual. G.L.U.E. is an adhesive process to allow each individual to be firmly…

  11. N-n-butyl haloperidol iodide protects cardiomyocytes against hypoxia/reoxygenation injury by inhibiting autophagy.

    PubMed

    Wang, Bin; Zhong, Shuping; Zheng, Fuchun; Zhang, Yanmei; Gao, Fenfei; Chen, Yicun; Lu, Binger; Xu, Han; Shi, Ganggang

    2015-09-22

    N-n-butyl haloperidol iodide (F2), a novel compound derived from haloperidol, protects against the damaging effects of ischemia/reperfusion (I/R) injury in vitro and in vivo. In this study, we hypothesized the myocardial protection of F2 on cardiomyocyte hypoxia/reoxygenation (H/R) injury is mediated by inhibiting autophagy in H9c2 cells. The degree of autophagy by treatment with F2 exposed to H/R in H9c2 cell was characterized by monodansylcadaverine, transmission electron microscopy, and expression of autophagy marker protein LC3. Our results indicated that treatment with F2 inhibited autophagy in H9c2 cells exposed to H/R. 3-methyladenine, an inhibitor of autophagy, suppressed H/R-induced autophagy, and decreased apoptosis, whereas rapamycin, a classical autophagy sensitizer, increased autophagy and apoptosis. Mechanistically, macrophage migration inhibitory factor (MIF) was inhibited by F2 treatment after H/R. Accordingly, small interfering RNA (siRNA)-mediated MIF knockdown decreased H/R-induced autophagy. In summary, F2 protects cardiomyocytes during H/R injury through suppressing autophagy activation. Our results provide a new mechanistic insight into a functional role of F2 against H/R-induced cardiomyocyte injury and death.

  12. [Research progress on identification and quality evaluation of glues medicines].

    PubMed

    Li, Hui-Hu; Ren, Gang; Chen, Li-Min; Zhong, Guo-Yue

    2018-01-01

    Glues medicines is a special kind of traditional Chinese medicine.As the market demand is large, the raw materials are in short supply and lacks proper quality evaluation technology, which causes inconsistent quality of products on the market. Its authentic identification and evaluation stay a problem to be solved. In this paper, the research progress of the methods and techniques of the evaluation of the identification and quality of glues medicines were reviewed. The researches of medicinal glue type identification and quality evaluation mainly concentrated in four aspects of medicinal materials of physical and chemical properties, trace elements, organic chemicals and biological genetic methods and techniques. The methods of physicochemical properties include thermal analysis, gel electrophoresis, isoelectric focusing electrophoresis, infrared spectroscopy, gel exclusion chromatography, and circular dichroism. The methods including atomic absorption spectrometry, X-ray fluorescence spectrometry, plasma emission spectrometry and visible spectrophotometry were used for the study of the trace elements of glues medicines. The organic chemical composition was studied by methods of composition of amino acids, content detection, odor detection, lipid soluble component, organic acid detection. Methods based on the characteristics of biogenetics include DNA, polypeptide and amino acid sequence difference analysis. Overall, because of relative components similarity of the glues medicines (such as amino acids, proteins and peptides), its authenticity and quality evaluation index is difficult to judge objectively, all sorts of identification evaluation methods have different characteristics, but also their limitations. It indicates that further study should focus on identification of evaluation index and various technology integrated application combining with the characteristics of the production process. Copyright© by the Chinese Pharmaceutical Association.

  13. Photoinduced Bioorthogonal 1,3-Dipolar Poly-cycloaddition Promoted by Oxyanionic Substrates for Spatiotemporal Operation of Molecular Glues.

    PubMed

    Hatano, Junichi; Okuro, Kou; Aida, Takuzo

    2016-01-04

    PGlue(PZ), a pyrazoline (PZ)-based fluorescent adhesive which can be generated spatiotemporally in living systems, was developed. Since PGlue(PZ) carries many guanidinium ion (Gu(+)) pendants, it strongly adheres to various oxyanionic substrates through a multivalent salt-bridge interaction. PGlue(PZ) is given by bioorthogonal photopolymerization of a Gu(+)-appended monomer (Glue(TZ)), bearing tetrazole (TZ) and olefinic termini. Upon exposure to UV light, Glue(TZ) transforms into a nitrileimine (NI) intermediate (Glue(NI)), which is eligible for 1,3-dipolar polycycloaddition. However, Glue(NI) in aqueous media can concomitantly be deactivated into Glue(WA) by the addition of water, and the polymerization hardly occurs unless Glue(NI) is concentrated. We found that, even under high dilution, Glue(NI) is concentrated on oxyanionic substrates to a sufficient level for the polymerization, so that their surfaces can be point-specifically functionalized with PGlue(PZ) by the use of a focused beam of UV light. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. An ion-pair principle for enantioseparations of basic analytes by nonaqueous capillary electrophoresis using the di-n-butyl L-tartrate-boric acid complex as chiral selector.

    PubMed

    Wang, Li-Juan; Liu, Xiu-Feng; Lu, Qie-Nan; Yang, Geng-Liang; Chen, Xing-Guo

    2013-04-05

    A chiral recognition mechanism of ion-pair principle has been proposed in this study. It rationalized the enantioseparations of some basic analytes using the complex of di-n-butyl l-tartrate and boric acid as the chiral selector in methanolic background electrolytes (BGEs) by nonaqueous capillary electrophoresis (NACE). An approach of mass spectrometer (MS) directly confirmed that triethylamine promoted the formation of negatively charged di-n-butyl l-tartrate-boric acid complex chiral counter ion with a complex ratio of 2:1. And the negatively charged counter ion was the real chiral selector in the ion-pair principle enantioseparations. It was assumed that triethylamine should play its role by adjusting the apparent acidity (pH*) of the running buffer to a higher value. Consequently, the effects of various basic electrolytes including inorganic and organic ones on the enantioseparations in NACE were investigated. The results showed that most of the basic electrolytes tested were favorable for the enantioseparations of basic analytes using di-n-butyl l-tartrate-boric acid complex as the chiral ion-pair selector. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Autologous fibrin glue: the last step in operative hemostasis.

    PubMed

    Tawes, R L; Sydorak, G R; DuVall, T B

    1994-08-01

    Fibrin glue may be the perfect hemostatic agent for operative use as it seals in minutes, has no tissue toxicity, reabsorbs, and promotes local tissue growth and repair. Use in the United States has been limited because of lack of Food and Drug Administration approval of the commercial homologous products, lack of a concentrated source of fibrinogen, and because of the potential for viral transmission, particularly hepatitis, with pooled homologous plasma and cryoprecipitate-based methods. Autologous fibrin glue (AFG) obviates these problems. During the past year, we obtained AFG through the same routine predonation procedure as with red blood cells before major elective surgery. Intraoperatively, we made AFG from the platelet-rich plasma derived from the Plasma-Saver. Our experience has been with 36 patients undergoing aortic, thoracoabdominal, and thoracic surgery, as well as patch graft angioplasty cases. Fibrin glue formation mimics the final stage in the coagulation cascade. The AFG from predonation acts more like an epoxy glue, while the AFG made during surgery is less viscous and acts more like a sealant because of the lesser concentration of fibrinogen in platelet-rich plasma. In emergencies, however, the intraoperative method is obviously the only choice available, and it is a useful adjunct to hemostasis at the end of the procedure. The technique will be described. This relatively new approach to hemostasis should gain popularity because it is easy and fairly inexpensive to produce, and because the patient's own blood is used.

  16. Injectable tissue-engineered cartilage using commercially available fibrin glue.

    PubMed

    Cakmak, Ozcan; Babakurban, Seda T; Akkuzu, Hatice G; Bilgi, Selcuk; Ovalı, Ercüment; Kongur, Merve; Altintas, Hande; Yilmaz, Bayram; Bilezikçi, Banu; Celik, Zerrin Y; Yakicier, Mustafa C; Sahin, Feride I

    2013-12-01

    To achieve injectable tissue-engineered cartilage using a commercially available fibrin sealant, and to determine the most suitable fibrin glue concentration, cartilage source, and cultured chondrocyte concentration. Animal research. A total of 28 immunocompetent New Zealand white rabbits were divided into four groups. The cultured chondrocytes from different anatomical sources carried in fibrin glue with and without aprotinin in different concentrations of fibrinogen and thrombin (Tisseell), were injected into forehead and interocular regions of the rabbits. The new tissue formation was harvested at 8 weeks and analyzed through gross and histological analysis. The new tissue formations were found in round, elliptical, and flat forms. The mean value of Tisseell and cell suspension was 0.8 cc in all of the rabbits' injection regions, but the mean volume of the samples in which immature cartilage matrix and mature cartilage was 0.1 cc. In the 20 of the 55 injection regions of rabbits (36, 36%), mature and/or immature cartilage formation were observed. We observed inflammatory reactions, abscess formation, and foreign body reactions around the new cartilage tissue of tissue-engineered cartilage. The comparison of results using different cartilage sources, chondrocyte concentrations, or different fibrin glue concentrations did not show any significant difference. We observed that changing the concentrations of ingredients of commercially available fibrin glue, the source of the cartilage, or the cultured chondrocyte concentration did not have significant effect on neocartilage formation. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  17. Measurement of radiation damage on an epoxy-based optical glue

    NASA Astrophysics Data System (ADS)

    Huang, H. C.; Peng, K. C.; Sahu, S. K.; Ueno, K.; Chang, Y. H.; Wang, C. H.; Hou, W. S.

    1997-02-01

    We measured the radiation damage on an optical glue called Eccobond-24, which is a candidate for CsI and BGO crystal calorimeters of the BELLE detector of the KEK B-factory. Absorption spectrophotometry in the range 300-800 nm was used to monitor the radiation damage. The maximum equivalent dose was 1.64 Mrad. The glue shows effects of damage, but is acceptable for the radiation level in the above-mentioned experiment.

  18. Nucleotide excision repair modulates the cytotoxic and mutagenic effects of N-n-butyl-N-nitrosourea in cultured mammalian cells as well as in mouse splenocytes in vivo.

    PubMed

    Bol, S A; van Steeg, H; van Oostrom, C T; Tates, A D; Vrieling, H; de Groot, A J; Mullenders, L H; van Zeeland, A A; Jansen, J G

    1999-05-01

    The butylating agent N-n-butyl-N-nitrosourea (BNU) was employed to study the role of nucleotide excision repair (NER) in protecting mammalian cells against the genotoxic effects of monofunctional alkylating agents. The direct acting agent BNU was found to be mutagenic in normal and XPA mouse splenocytes after a single i.p. treatment in vivo. After 25 and 35 mg/kg BNU, but not after 75 mg/ kg, 2- to 3-fold more hprt mutants were detected in splenocytes from XPA mice than from normal mice. Using O6-alkylguanine-DNA alkyltransferase (AGT)-deficient hamster cells, it was found that NER-deficient CHO UV5 cells carrying a mutation in the ERCC-2 gene were 40% more mutable towards lesions induced by BNU when compared with parental NER-proficient CHO AA8 cells. UV5 cells were 1.4-fold more sensitive to the cytotoxic effects of BNU compared with AA8 cells. To investigate whether this increased sensitivity of NER-deficient cells is modulated by AGT activity, cell survival studies were performed in human and mouse primary fibroblasts as well. BNU was 2.7-fold more toxic for mouse XPA fibroblasts compared with normal mouse fibroblasts. Comparable results were found for human fibroblasts. Taken together these data indicate that the role of NER in protecting rodent cells against the mutagenic and cytotoxic effects of the alkylating agent BNU depends on AGT.

  19. Fibrin glue versus sutures for conjunctival autografting in primary pterygium surgery.

    PubMed

    Romano, Vito; Cruciani, Mario; Conti, Luigi; Fontana, Luigi

    2016-12-02

    Pterygium, a growth of the conjunctiva over the cornea, is a progressive disease leading in advanced stages to visual impairment, restriction of ocular motility, chronic inflammation and cosmetic concerns. Surgical removal is the treatment of choice, but recurrence can be a problem. Currently the best surgical option in terms of recurrence is conjunctival autograft. To date the most common surgical methods of attaching conjunctival autografts to the sclera are through suturing or fibrin glue. Each method presents its own advantages and disadvantages. Sutures require considerable skill from the surgeon and can be associated with a prolonged operation time, postoperative discomfort and suture-related complications, whereas fibrin glue may give a decreased operation time, improve postoperative comfort and avoid suture-related problems. To assess the effectiveness of fibrin glue compared to sutures in conjunctival autografting for the surgical treatment of pterygium. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 9), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to October 2016), Embase (January 1980 to October 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 14 October 2016. We included randomised controlled trials (RCTs) in any setting where fibrin glue was compared with sutures to treat people with pterygium. Two review authors independently screened the search results, assessed trial quality, and extracted data using standard methodological procedures expected by Cochrane. Our primary outcome was recurrence of pterygium defined as

  20. Butylate

    Integrated Risk Information System (IRIS)

    Butylate ; CASRN 2008 - 41 - 5 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Effects

  1. Alternative mounting media for preservation of some protozoa.

    PubMed

    Criado-Fornelio, A; Heredero-Bermejo, I; Pérez-Serrano, J

    2014-10-01

    Protozoa resistant stages are disintegrated when mounted in toluene-based media. To overcome such problem, three toluene-free mountants were tested on preserve Acanthamoeba spp and gregarines. Two commercial glues based on cyanoacrylate or trimethoxysilane were suitable for preserving both cysts and trophozoites. Hoyer's medium showed good results for mounting gregarine oocysts. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Herbicidal cyanoacrylates with antimicrotubule mechanism of action.

    PubMed

    Tresch, Stefan; Plath, Peter; Grossmann, Klaus

    2005-11-01

    The herbicidal mode of action of the new synthetic cyanoacrylates ethyl (2Z)-3-amino-2-cyano-4-ethylhex-2-enoate (CA1) and its isopropyl ester derivative CA2 was investigated. For initial characterization, a series of bioassays was used indicating a mode of action similar to that of mitotic disrupter herbicides such as the dinitroaniline pendimethalin. Cytochemical fluorescence studies including monoclonal antibodies against polymerized and depolymerized tubulin and a cellulose-binding domain of a bacterial cellulase conjugated to a fluorescent dye were applied to elucidate effects on cell division processes including mitosis and microtubule and cell wall formation in maize roots. When seedlings were root treated with 10 microM of CA1 or CA2, cell division activity in meristematic root tip cells decreased within 4 h. The chromosomes proceeded to a condensed state of prometaphase, but were unable to progress further in the mitotic cycle. The compounds caused a complete loss of microtubular structures, including preprophase, spindle, phragmoplast and cortical microtubules. Concomitantly, in the cytoplasm, an increase in labelling of free tubulin was observed. This suggests that the herbicides disrupt polymerization and microtubule stability, whereas tubulin synthesis or degradation appeared not to be affected. In addition, cellulose labelling in cell walls of root tip cells was not influenced. The effects of CA1 and CA2 were comparable with those caused by pendimethalin. In transgenic Arabidopsis plants expressing a green fluorescent protein-microtubule-associated protein4 fusion protein, labelled arrays of cortical microtubules in living epidermal cells of hypocotyls collapsed within 160 min after exposure to 10 microM CA1 or pendimethalin. Moreover, a dinitroaniline-resistant biotype of goosegrass (Eleusine indica (L) Gaertn) with a point mutation in alpha-tubulin showed cross-resistance against CA1 and CA2. The results strongly indicate that the cyanoacrylates are

  3. Use of a skin adhesive (octyl-2-cyanoacrylate) and the optimum reinforcing combination for suturing wounds.

    PubMed

    Chigira, Miho; Akimoto, Masataka

    2005-01-01

    The adhesion strength of a skin adhesive, octyl-2-cyanoacrylate (Dermabond), was measured under various conditions using porcine skin. The combined use of a skin adhesive and a skin closure tape (n = 5) was significantly stronger than a single application of skin adhesive (n = 5) (p < 0.01). We have tentatively named the wound closure in which a skin adhesive and reinforcement material were combined the Reinforcing Combination Method. To obtain optimum conditions, further studies were done for sequence of application, type of reinforcement material, a number of layers, and width of the suture. The optimum condition for the reinforcement combination was established by applying one layer of skin adhesive over a skin closure tape, over one layer of skin adhesive, with a suture width of 4 cm. This reinforcement combination might be useful in clinical practice.

  4. IRIS Toxicological Review of Ethylene Glycol Mono Butyl ...

    EPA Pesticide Factsheets

    EPA has finalized the Toxicological Review of Ethylene Glycol Mono Butyl Ether: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health. N/A

  5. Di-n-butyl Phthalate (DNBP) and Diisobutyl Phthalate (DiBP) Metabolism in a Human Volunteer after Single Oral Doses [Journal Article

    EPA Science Inventory

    An individual (male, 36 years, 87 kg) ingested two separate doses of di-n-butyl phthalate (DnBP) and diisobutyl phthalate (DiBP) at a rate of ~60 µg/kg. Key monoester and oxidized metabolites were identified and quantified in urine continuously collected until 48 hours post dos...

  6. Diagnosis of gynecological pseudoaneurysms and embolization with cyanoacrylate.

    PubMed

    Fernández Bermúdez, M J; Fernández Martínez, A M; Domitrovic, L A; Balboa Arregui, Ó

    Pseudoaneurysms of the uterine artery are an uncommon cause of severe gynecological bleeding secondary to surgical manipulation of the pelvis or to instrumental delivery. The different imaging techniques are of vital importance in the diagnosis. Angiography is the technique used for confirmation and also for treatment in many cases. Endovascular treatment by embolizing the pseudoaneurysm has become established as the treatment of choice, making it possible to avoid hysterectomy in women of childbearing age. This article presents two cases of gynecological bleeding due to pseudoaneurysms (one secondary to surgery and one secondary to childbirth) that were embolized in a novel way using cyanoacrylate. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Risk factor analysis for massive lymphatic ascites after laparoscopic retroperitonal lymphadenectomy in gynecologic cancers and treatment using intranodal lymphangiography with glue embolization

    PubMed Central

    2016-01-01

    Objective To evaluate risk factors for massive lymphatic ascites after laparoscopic retroperitoneal lymphadenectomy in gynecologic cancer and the feasibility of treatments using intranodal lymphangiography (INLAG) with glue embolization. Methods A retrospective analysis of 234 patients with gynecologic cancer who received laparoscopic retroperitonal lymphadenectomy between April 2006 and November 2015 was done. In June 2014, INLAG with glue embolization was initiated to manage massive lymphatic ascites. All possible clinicopathologic factors related to massive lymphatic ascites were determined in the pre-INLAG group (n=163). Clinical courses between pre-INLAG group and post-INLAG group (n=71) were compared. Results In the pre-INLAG group (n=163), four patients (2.5%) developed massive lymphatic ascites postoperatively. Postoperative lymphatic ascites was associated with liver cirrhosis (three cirrhotic patients, p<0.001). In the post-INLAG group, one patient with massive lymphatic ascites had a congestive heart failure and first received INLAG with glue embolization. She had pelvic drain removed within 7 days after INLAG. The mean duration of pelvic drain and hospital stay decreased after the introduction of INLAG (13.2 days vs. 10.9 days, p=0.001; 15.2 days vs. 12.6 days, p=0.001). There was no evidence of recurrence after this procedure. Conclusion Underlying medical conditions related to the reduced effective circulating volume, such as liver cirrhosis and heart failure, may be associated with massive lymphatic ascites after retroperitoneal lymphadenectomy. INLAG with glue embolization can be an alternative treatment options to treat leaking lymphatic channels in patients with massive lymphatic leakage. PMID:27171674

  8. Bis[μ-N-(tert-butyl­dimethyl­silyl)-N-(pyridin-2-ylmeth­yl)amido]­bis­[methyl­cobalt(II)

    PubMed Central

    Malassa, Astrid; Agthe, Christine; Görls, Helmar; Westerhausen, Matthias

    2012-01-01

    The green title complex, [Co2(CH3)2(C12H21N2Si)2], was obtained from bis­{[μ-N-tert-butyl­dimethyl­silyl-N-(pyridin-2-ylmeth­yl)amido]­chloridocobalt(II)} and methyl­lithium in diethyl ether at 195 K via a metathesis reaction. The dimeric cobalt(II) complex exhibits a crystallographic center of inversion in the middle of the Co2N2 ring (average Co—N = 2.050 Å). The CoII atom shows a distorted tetra­hedral coordination sphere. The exocyclic Co—N bond length to the pyridyl group shows a similar value of 2.045 (4) Å. The exocyclic methyl group has a rather long Co—C bond length of 2.019 (5) Å. PMID:22969464

  9. Emulsion Polymerization of Butyl Acrylate: Spin Trapping and EPR Study

    NASA Technical Reports Server (NTRS)

    Kim, S.; Westmoreland, D.

    1994-01-01

    The propagating radical in the emulsion polymerization reaction of butyl acrylate was detected by Electron Paramagnetic Resonance spectroscopy using two spin trapping agents, 2-methyl-2nitrosopropane and alpha -N-tert-butylnitrone.

  10. Use of 2-octyl cyanoacrylate adhesive in rat liver induced lesion.

    PubMed

    Santos, Orlando José dos; Marques, Giancarlo de Souza; Sauaia Filho, Euler Nicolau; Frota, Gustavo Medeiros; Santos, Rayan Haquim Pinheiro; Santos, Rennan Abud Pinheiro

    2012-09-01

    To evaluate the healing process of rat traumatic liver lesion corrected with the use of 2-octyl cyanoacrylate adhesive, compared to the use of biologically absorbable chromed catgut thread suture. Thirty mail adult rats were divided into two groups (15 per group) according to the used method for liver lesion correction as follows: adhesive group (AG), and catgut group (CG); each group being divided into three subsets of five animals (7th, 14th, and 21st day), respectively, according to post-surgery evaluation. All animals were submitted to homogeneous lesion applying synthetic bonding to AG and using chromed catgut suture to CG for lesion correction. Macroscopic and microscopic parameters of healing processes were evaluated. Both groups of animals showed excellent abdominal wall healing, with no evidence of infection, and no abdominal cavity peritonitis or abscess. The presence of adherence was observed in both groups with no statistically significant difference. As to macroscopic evaluation, there was statistically significant difference with respect to specific factors of clinical inflammation (ischemic inflammation and giant celular inflammatory reaction) between animals evaluated on the 10th day (ischemic necrosis and giant cellular inflammatory reaction) among animals evaluated on the 14th day (A14 versus C14). Applying 2-octyl-cyanoacrylate adhesive for correcting rat liver lesion does not change healing process when compared to the use of chromed catgut stitch.

  11. Effect of fibrin glue occlusion of the hepatobiliary tract on thioacetamide-induced liver failure.

    PubMed

    Schmandra, T C; Bauer, H; Petrowsky, H; Herrmann, G; Encke, A; Hanisch, E

    2001-07-01

    Expression and activation of hepatocyte growth factor (HGF) is stimulated by a complex system of interacting proteins, with thrombin playing an initial role in this process. The impact of temporary occlusion of the hepatobiliary tract with fibrin glue (major component thrombin) on the HGF system in acute and chronic liver damage in a rat model was investigated. Chronic liver damage was induced in 40 rats by daily intraperitoneal application of thioacetamide (100 mg/kg) for 14 days. After 7 days half of them received an injection of 0.2 mL fibrin glue into the hepatobiliary system. Daily intraperitoneal administration of thioacetamide continued for 7 consecutive days. The rats were then sacrificed for blood and tissue analysis. Acute liver failure was induced in 12 rats by intraperitoneal administration of a lethal dose of thioacetamide (500 mg/kg per day for 3 days) after an injection with 0.2 mL fibrin glue into their hepatobiliary tract. Survival rates and histological outcome were investigated and compared with control animals. Fibrin glue occluded rats showed significantly lower liver enzyme activities and serum levels of bilirubin, creatinine and urea nitrogen. Immunohistochemistry revealed a significant increase in c-met-, HGFalpha- and especially HGFbeta-positive cells. Rats subjected to a lethal dose of thioacetamide survived when fibrin glue was applied 24 hours prior to the toxic challenge. These animals showed normal liver structure and no clinical abnormalities. Fibrin glue occlusion of the hepatobiliary tract induces therapeutic and prophylactic effects on chronic and acute liver failure by stimulating the HGF system. Therefore, fibrin glue occlusion might be useful in treating toxic liver failure.

  12. Application of COMPONT Medical Adhesive Glue for Tension-Reduced Duraplasty in Decompressive Craniotomy

    PubMed Central

    Zhou, Yujia; Wang, Gesheng; Liu, Jialin; Du, Yong; Wang, Lei; Wang, Xiaoyong

    2016-01-01

    Background The aim of this study was to evaluate the application of medical adhesive glue for tension-reduced duraplasty in decompressive craniotomy. Material/Methods A total of 56 cases were enrolled for this study from Jan 2013 to May 2015. All patients underwent decompressive craniotomy and the dura was repaired in all of them with tension-reduced duraplasty using the COMPONT medical adhesive to glue artificial dura together. The postoperative complications and the healing of dura mater were observed and recorded. Results No wound infection, epidural or subdural hematoma, cerebrospinal fluid leakage, or other complications associated with the procedure occurred, and there were no allergic reactions to the COMPONT medical adhesive glue. The second-phase surgery of cranioplasty was performed at 3 to 6 months after the decompressive craniotomy in 32 out of the 56 cases. During the cranioplasty we observed no adherence of the artificial dura mater patch to the skin flap, no residual COMPONT glue, or hydropic or contracture change of tissue at the surgical sites. Additionally, no defect or weakening of the adherence between the artificial dura mater patch and the self dura matter occurred. Conclusions COMPONT medical adhesive glue is a safe and reliable tool for tension-reduced duraplasty in decompressive craniotomy. PMID:27752035

  13. Hearing loss in a glue sniffer.

    PubMed

    Williams, D M

    1988-10-01

    A case is presented of a 27-year-old glue sniffing woman with sensorineural hearing loss, optic atrophy and global brain damage. This form of addiction has not received much attention as a cause of otologic catastrophes, and should be borne in mind where similar cases come to the otolaryngologist.

  14. Preparative enantioseparation of propafenone by counter-current chromatography using di-n-butyl L-tartrate combined with boric acid as the chiral selector.

    PubMed

    Tong, Shengqiang; Shen, Mangmang; Zheng, Ye; Chu, Chu; Li, Xing-Nuo; Yan, Jizhong

    2013-09-01

    This paper extends the research of the utilization of borate coordination complexes in chiral separation by counter-current chromatography (CCC). Racemic propafenone was successfully enantioseparated by CCC with di-n-butyl l-tartrate combined with boric acid as the chiral selector. The two-phase solvent system was composed of chloroform/ 0.05 mol/L acetate buffer pH 3.4 containing 0.10 mol/L boric acid (1:1, v/v), in which 0.10 mol/L di-n-butyl l-tartrate was added in the organic phase. The influence of factors in the enantioseparation of propafenone were investigated and optimized. A total of 92 mg of racemic propafenone was completely enantioseparated using high-speed CCC in a single run, yielding 40-42 mg of (R)- and (S)-propafenone enantiomers with an HPLC purity over 90-95%. The recovery for propafenone enantiomers from fractions of CCC was in the range of 85-90%. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Composition Formulas of Inorganic Compounds in Terms of Cluster Plus Glue Atom Model.

    PubMed

    Ma, Yanping; Dong, Dandan; Wu, Aimin; Dong, Chuang

    2018-01-16

    The present paper attempts to identify the molecule-like structural units in inorganic compounds, by applying the so-called "cluster plus glue atom model". This model, originating from metallic glasses and quasi-crystals, describes any structure in terms of a nearest-neighbor cluster and a few outer-shell glue atoms, expressed in the cluster formula [cluster](glue atoms). Similar to the case for normal molecules where the charge transfer occurs within the molecule to meet the commonly known octet electron rule, the octet state is reached after matching the nearest-neighbor cluster with certain outer-shell glue atoms. These kinds of structural units contain information on local atomic configuration, chemical composition, and electron numbers, just as for normal molecules. It is shown that the formulas of typical inorganic compounds, such as fluorides, oxides, and nitrides, satisfy a similar octet electron rule, with the total number of valence electrons per unit formula being multiples of eight.

  16. 27 CFR 21.101 - tert-Butyl alcohol.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false tert-Butyl alcohol. 21.101....101 tert-Butyl alcohol. (a) Acidity (as acetic acid). 0.003 percent by weight maximum. (b) Color. Colorless. (c) Distillation range. When 100 ml of tertiary butyl alcohol are distilled, none should distill...

  17. 27 CFR 21.101 - tert-Butyl alcohol.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false tert-Butyl alcohol. 21.101....101 tert-Butyl alcohol. (a) Acidity (as acetic acid). 0.003 percent by weight maximum. (b) Color. Colorless. (c) Distillation range. When 100 ml of tertiary butyl alcohol are distilled, none should distill...

  18. Antibacterial properties of propolis (bee glue).

    PubMed Central

    Grange, J M; Davey, R W

    1990-01-01

    Propolis (bee glue) was found to have antibacterial activity against a range of commonly encountered cocci and Gram-positive rods, including the human tubercle bacillus, but only limited activity against Gram-negative bacilli. These findings confirm previous reports of antimicrobial properties of this material, possibly attributable to its high flavonoid content. PMID:2182860

  19. Tetra-butyl-ammonium tetra-kis-(trimethyl-silanolato-κO)ferrate(III).

    PubMed

    Hay, Michael; Staples, Richard; Lee, Andre

    2012-09-01

    In the title salt, (C(16)H(36)N)[Fe(C(3)H(9)OSi)(4)], the cation contains a central N atom bonded to four n-butyl alkyl groups in a tetra-hedral arrangement, while the anion contains a central Fe(III) atom tetra-hedrally coordinated by four trimethyl-silanolate ligands.

  20. Photoclickable dendritic molecular glue: noncovalent-to-covalent photochemical transformation of protein hybrids.

    PubMed

    Uchida, Noriyuki; Okuro, Kou; Niitani, Yamato; Ling, Xiao; Ariga, Takayuki; Tomishige, Michio; Aida, Takuzo

    2013-03-27

    A water-soluble dendron with a fluorescein isothiocyanate (FITC) fluorescent label and bearing nine pendant guanidinium ion (Gu(+))/benzophenone (BP) pairs at its periphery (Glue(BP)-FITC) serves as a "photoclickable molecular glue". By multivalent salt-bridge formation between Gu(+) ions and oxyanions, Glue(BP)-FITC temporarily adheres to a kinesin/microtubule hybrid. Upon subsequent exposure to UV light, this noncovalent binding is made permanent via a cross-linking reaction mediated by carbon radicals derived from the photoexcited BP units. This temporal-to-permanent transformation by light occurs quickly and efficiently in this preorganized state, allowing the movements of microtubules on a kinesin-coated glass plate to be photochemically controlled. A fundamental difference between such temporal and permanent bindings was visualized by the use of "optical tweezers".

  1. Glue-induced birefringence in surface-attached FBG strain sensors

    NASA Astrophysics Data System (ADS)

    Helminger, Dominik; Daitche, Alexej; Roths, Johannes

    2014-05-01

    The influence of the gluing process on the birefringence of surface-glued FBGs that were inscribed in highly birefringence (HiBi) optical fibers of type Panda was studied by monitoring the variation of the birefringence during the gluing procedure. The isothermal curing process at 100°C of the epoxy-based adhesive is characterized by the reduction of birefringence during curing. Significant transversal strain is introduced into the fiber during the cool down period, which is due to different thermal expansion coefficients of the silica and the glue. When the slow axis of the HiBi fiber is oriented parallel to the surface, the glue-induced transversal strain reduces the birefringence of the fiber by ΔB = -6.6 10-5 and when it is perpendicular to the surface, it is increased by ΔB = 1.1 10-5. It can be estimated that for conventional FBGs in single mode fibers a glue-induced birefringence in the order of ΔB = 3.4 10-5 can be expected, which has to be taken into account if in surface-mounted FBG-based strain measurements a high accuracy has to be achieved.

  2. Optimization of performance parameters for large area silicon photomultipliers for use in the GlueX experiment

    NASA Astrophysics Data System (ADS)

    Janzen, Kathryn Louise

    Largely because of their resistance to magnetic fields, silicon photomultipliers (SiPMs) are being considered as the readout for the GlueX Barrel Calorimeter, a key component of the GlueX detector located immediately inside a 2.2 T superconducting solenoid. SiPMs with active area 1 x 1 mm2 have been investigated for use in other experiments, but detectors with larger active areas are required for the GlueX BCAL. This puts the GlueX collaboration in the unique position of being pioneers in the use of this frontend detection revolution by driving the technology for larger area sensors. SensL, a photonics research and development company in Ireland, has been collaborating with the University of Regina GlueX group to develop prototype large area SiPMs comprising 16 - 3x3 mm2 cells assembled in a close-packed matrix. Performance parameters of individual SensL 1x1 mm2 and 3x3 mm2 SiPMs along with prototype SensL SiPM arrays are tested, including current versus voltage characteristics, photon detection efficiency, and gain uniformity, in an effort to determine the suitability of these detectors to the GlueX BCAL readout.

  3. Respiratory and skin effects of exposure to wood dust from the rubber tree Hevea brasiliensis.

    PubMed

    Sripaiboonkij, P; Phanprasit, W; Jaakkola, M S

    2009-07-01

    Potential health effects related to wood dust from the rubber tree, which produces natural rubber latex, have not been previously investigated. The main aim of this study was to investigate the relations of rubber tree dust exposure to respiratory and skin symptoms, asthma and lung function. A cross-sectional study was conducted among 103 workers (response rate 89%) in a rubber tree furniture factory and 76 office workers (73%) in four factories in Thailand. All participants answered a questionnaire and performed spirometry. Inhalable dust levels were measured in different work areas. Factory workers showed increased risk of wheezing, nasal symptoms and asthma compared to office workers. There was a dose-dependent increase in wheeze and skin symptoms in relation to dust level. Significantly increased risks of nasal symptoms (adj OR 3.67, 95% CI 1.45 to 9.28) and asthma (8.41, 1.06 to 66.60) were detected in the low exposure category. Workers exposed to ethyl cyanoacrylate glue had significantly increased risk of cough, breathlessness and nasal symptoms. There was dose-dependent reduction in spirometric lung function with wood dust level. This study provides new evidence that workers exposed to wood dust from the rubber tree experience increased risk of nasal symptoms, wheeze, asthma and skin symptoms and have reduced spirometric lung function. Exposure to cyanoacrylate is related to significantly increased respiratory symptoms. Results suggest that the furniture industry using rubber tree wood should implement appropriate exposure control measures to reduce wood dust exposure and cyanoacrylate glue exposure to protect their employees.

  4. Biodegradation of di-n-butyl phthalate by bacterial consortium LV-1 enriched from river sludge

    PubMed Central

    Li, Fangfang; Ruan, Xinling; Song, Jian; Lv, Lv; Chai, Liyuan; Yang, Zhihui; Luo, Lin

    2017-01-01

    A stable bacterial consortium (LV-1) capable of degrading di-n-butyl phthalate (DBP) was enriched from river sludge. Community analysis revealed that the main families of LV-1 are Brucellaceae (62.78%) and Sinobacteraceae (14.83%), and the main genera of LV-1 are Brucella spp. (62.78%) and Sinobacter spp. (14.83%). The optimal pH and temperature for LV-1 to degrade DBP were pH 6.0 and 30°C, respectively. Inoculum size influenced the degradation ratio when the incubation time was < 24 h. The initial concentration of DBP also influenced the degradation rates of DBP by LV-1, and the degradation rates ranged from 69.0–775.0 mg/l/d in the first 24 h. Degradation of DBP was best fitted by first-order kinetics when the initial concentration was < 300 mg/l. In addition, Cd2+, Cr6+, and Zn2+ inhibited DBP degradation by LV-1 at all considered concentrations, but low concentrations of Pb2+, Cu2+, and Mn2+ enhanced DBP degradation. The main intermediates (mono-ethyl phthalate [MEP], mono-butyl phthalate [MBP], and phthalic acid [PA]) were identified in the DBP degradation process, thus a new biochemical pathway of DBP degradation is proposed. Furthermore, LV-1 also degraded other phthalates with shorter ester chains (DMP, DEP, and PA). PMID:28542471

  5. Synthesis and characterization of a novel aminopolycarboxylate complexant for efficient trivalent f-element differentiation: N-butyl-2-acetamide-diethylenetriamine- N, N', N", N"-tetraacetic acid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heathman, Colt R.; Grimes, Travis S.; Jansone-Popova, Santa

    The novel metal ion complexant N-butyl-2-acetamide-diethylenetriamine-N,N',N",N"-tetraacetic acid (DTTA-BuA) uses an amide functionalization to increase the total ligand acidity and attain efficient 4f/5f differentiation in low pH conditions. The amide, when located on the diethylenetriamine platform containing four acetate pendant arms maintains the octadentate coordination sphere for all investigated trivalent f-elements. This compact coordination environment inhibits the protonation of LnL- complexes, as indicated by lower K 111 constants relative to the corresponding protonation site of the free ligand. For actinide ions, the enhanced stability of AnL- lowers the K 111 for americium and curium beyond the aptitude of potentiometric detection. Densitymore » functional theory computations indicate the difference in the back-donation ability of Am 3+ and Eu 3+ f-orbitals is mainly responsible for stronger proton affinity of EuL- compared to AmL-. The measured stability constants for the formation of AmL- and CmL- complexes are consistently higher, relative to ML- complexes with lanthanides of similar charge density. When compared with the conventional aminopolycarboxylate diethylenetriamine pentaacetic acid (DTPA), the modified DTTA-BuA complexant features higher ligand acidity and the important An 3+/Ln 3+ differentiation when deployed on a liquid–liquid distribution platform.« less

  6. Photocurable surgical tissue adhesive glues composed of photoreactive gelatin and poly(ethylene glycol) diacrylate.

    PubMed

    Nakayama, Y; Matsuda, T

    1999-01-01

    This article presents a novel photochemically driven surgical tissue adhesive technology using photoreactive gelatins and a water-soluble difunctional macromer (poly(ethylene glycol) diacrylate: PEGDA).The gelatins were partially derivatized with photoreactive groups, such as ultraviolet light (UV)-reactive benzophenone and visible light-reactive xanthene dye (e.g., fluorescein sodium salt, eosin Y, and rose bengal). A series of the prepared photocurable tissue adhesive glues, consisting of the photoreactive gelatin, PEGDA, and a saline solution with or without ascorbic acid as a reducing agent, were viscous solutions under warming, and their effectiveness was evaluated as hemostasis- and anastomosis-aid in cardiovascular surgery. Regardless of the type of photoreactive groups, the irradiation of the photocurable tissue adhesive glues by UV or visible light within 1 min produced water-swollen gels, which had a high adhesive strength to wet collagen film. These were due to the synergistic action of photoreactive group-initiated photo-cross-linking and photograft polymerization. An increase in the irradiation time resulted in increased gel yield and reduced water swellability. A decrease in the molecular weight of PEGDA and an increase in concentration of both gelatin and PEGDA resulted in reduced water swellability and increased tensile and burst strengths of the resultant gels. In rats whose livers were injured with a trephine in laparotomy, the bleeding spots were coated with the photocurable adhesive glue and irradiated through an optical fiber. The coated solution was immediately converted to a swollen gel. The gel was tightly adhered to the liver tissue presumably by interpenetration, and concomitantly hemostasis was completed. The anastomosis treatment with the photocurable glue in the canine abdominal or thoracic aortas incised with a knife resulted in little bleeding under pulsatile flow after declamping. Histological examination showed that the glues

  7. Autologous Blood Versus Fibrin Glue in Pterygium Excision With Conjunctival Autograft Surgery.

    PubMed

    Nadarajah, Gaayathri; Ratnalingam, Vanitha Hema; Mohd Isa, Hazlita

    2017-04-01

    To evaluate graft stability and recurrence rate between fibrin glue and autologous blood in pterygium conjunctival autograft surgery. A prospective, randomized, single-blinded clinical trial to assess the efficacy of autologous blood in place of fibrin glue in pterygium surgery. A total of 120 eyes of 111 patients were randomized according to pterygium morphology, to undergo pterygium surgery with autografting using either autologous blood or fibrin glue. All patients were operated by a single surgeon; 58 eyes were operated using fibrin glue and 62 eyes had a conjunctival autograft with autologous blood. Patients were seen on postoperative day 1, 1 week, 1 month, 6 months, and 1 year after surgery. Graft stability and pterygium recurrence were graded by an independent observer who was masked to the method of treatment. All 120 eyes completed the 1-year follow-up. Graft loss was seen only in the autologous blood group. Of the 62 eyes in this group, a total of 15 (24.2%) grafts dislodged. Recurrence was calculated after excluding grafts that were dislodged. Of the 105 patients, there were a total of 7 recurrences, 2 (3.4%) from the fibrin adhesive method and 5 (10.6%) from the autologous blood method. This was not statistically significant (P = 0.238). Autologous blood does not exhibit similar graft stability seen with fibrin glue. Although the recurrence rate may not be significant, careful patient selection and a standard method needs to be laid out before the use of this method is widely accepted.

  8. Experimental closure of gunshot wounds by fibrin glue with antibiotics in pigs.

    PubMed

    Djenić, Nebojša; Višnjić, Milan; Dragović, Saša; Bojanić, Vladmila; Bojanić, Zoran; Djurdjević, Dragan; Djindjić, Boris; Kostov, Miloš

    2015-09-01

    Gunshot wounds caused by the automatic rifle M70AB2 (AK-47) 7.62 mm, after the primary surgical management, were closed with delayed primary suture during the next four to seven days. This period coincides with the fibroblastic phase of wound healing. Fibrin glue is used as a local hemostatic and as a matrix for the local dosed release of antibiotics. Antibiotics addition to fibrin glue resulted in continuous diffusion into the surrounding next 4 to 7 days. The aim of this study was to create the preconditions for gunshot wounds closing without complications by the application of fibrin glue with antibiotics 24 h after primary surgical treatment. A total of 14 pigs were wounded in the gluteofemoral region by the bullet M67, initial velocity of 720 m/s. All wounded animals were surgically treated according to the principles of the war-surgery doctrine. Seven wounds were closed with primary delayed suture four days after the primary surgical treatment (traditional approach). Fibrin glue with antibiotics was introduced in seven wounds during the primary surgical treatment and primary delayed suture was done after 24 h. The macroscopic appearance and the clinical assessment of the wound were done during the primary surgical treatment and during its revision after 24 h, as well as histopathological findings at the days 4 and 7 after wounding. Gunshot wounds caused by the automatic rifle M70AB2 (AK-47) 7.62 mm, and treated with fibrin glue with antibiotics after primary surgical management, were closed with primary delayed suture after 24 h. In further wound evolution there were no complications. Uncomplicated soft-tissue wounds caused by an automatic M70AB2 rifle may be closed primarily with delayed suture without the risk of developing complications if on revision, 24 h after primary surgery, there were no present necrotic tissues, hematoma, and any signs of infection when fibrin glue with antibiotics (ceftriaxone and clindamycin) was applied. The use of this method

  9. Improved Bond Strength of Cyanoacrylate Adhesives Through Nanostructured Chromium Adhesion Layers

    NASA Astrophysics Data System (ADS)

    Gobble, Kyle; Stark, Amelia; Stagon, Stephen P.

    2016-09-01

    The performance of many consumer products suffers due to weak and inconsistent bonds formed to low surface energy polymer materials, such as polyolefin-based high-density polyethylene (HDPE), with adhesives, such as cyanoacrylate. In this letter, we present an industrially relevant means of increasing bond shear strength and consistency through vacuum metallization of chromium thin films and nanorods, using HDPE as a prototype material and cyanoacrylate as a prototype adhesive. For the as received HDPE surfaces, unmodified bond shear strength is shown to be only 0.20 MPa with a standard deviation of 14 %. When Cr metallization layers are added onto the HDPE at thicknesses of 50 nm or less, nanorod-structured coatings outperform continuous films and have a maximum bond shear strength of 0.96 MPa with a standard deviation of 7 %. When the metallization layer is greater than 50 nm thick, continuous films demonstrate greater performance than nanorod coatings and have a maximum shear strength of 1.03 MPa with a standard deviation of 6 %. Further, when the combination of surface roughening with P400 grit sandpaper and metallization is used, 100-nm-thick nanorod coatings show a tenfold increase in shear strength over the baseline, reaching a maximum of 2.03 MPa with a standard deviation of only 3 %. The substantial increase in shear strength through metallization, and the combination of roughening with metallization, may have wide-reaching implications in consumer products which utilize low surface energy plastics.

  10. Glue Spin and Helicity in the Proton from Lattice QCD.

    PubMed

    Yang, Yi-Bo; Sufian, Raza Sabbir; Alexandru, Andrei; Draper, Terrence; Glatzmaier, Michael J; Liu, Keh-Fei; Zhao, Yong

    2017-03-10

    We report the first lattice QCD calculation of the glue spin in the nucleon. The lattice calculation is carried out with valence overlap fermions on 2+1 flavor domain-wall fermion gauge configurations on four lattice spacings and four volumes including an ensemble with physical values for the quark masses. The glue spin S_{G} in the Coulomb gauge in the modified minimal subtraction (MS[over ¯]) scheme is obtained with one-loop perturbative matching. We find the results fairly insensitive to lattice spacing and quark masses. We also find that the proton momentum dependence of S_{G} in the range 0≤|p[over →]|<1.5  GeV is very mild, and we determine it in the large-momentum limit to be S_{G}=0.251(47)(16) at the physical pion mass in the MS[over ¯] scheme at μ^{2}=10  GeV^{2}. If the matching procedure in large-momentum effective theory is neglected, S_{G} is equal to the glue helicity measured in high-energy scattering experiments.

  11. Hydrolysis of tert-butyl formate: Kinetics, products, and implications for the environmental impact of methyl tert-butyl ether

    USGS Publications Warehouse

    Church, Clinton D.; Pankow, James F.; Tratnyek, Paul G.

    1999-01-01

    Asessing the environmental fate of methyl tert-butyl ether (MTBE) has become a subject of renewed interest because of the large quantities of this compound that are being used as an oxygenated additive in gasoline. Various studies on the fate of MTBE have shown that it can be degraded to tert-butyl formate (TBF), particularly in the atmosphere. Although it is generally recognized that TBF is subject to hydrolysis, the kinetics and products of this reaction under environmentally relevant conditions have not been described previously. In this study, we determined the kinetics of TBF hydrolysis as a function of pH and temperature. Over the pH range of 5 to 7, the neutral hydrolysis pathway predominates, with kN = (1.0 ± 0.2) × 10−6/s. Outside this range, strong pH effects were observed because of acidic and basic hydrolyses, from which we determined that kA = (2.7 ± 0.5) × 10−3/(M·s) and kB = 1.7 ± 0.3/(M·s). Buffered and unbuffered systems gave the same hydrolysis rates for a given pH, indicating that buffer catalysis was not significant under the conditions tested. The activation energies corresponding to kN, kA, and kBwere determined to be 78 ± 5, 59 ± 4, and 88 ±11 kJ/mol, respectively. In all experiments, tert-butyl alcohol was found at concentrations corresponding to stoichiometric formation from TBF. Based on our kinetics data, the expected half-life for hydrolysis of TBF at pH = 2 and 4°C (as per some standard preservation protocols for water sampling) is 6 h. At neutral pH and 22°C, the estimated half-life is 5 d, and at pH = 11 and 22°C, the value is only 8 min.

  12. Vascularization of conjunctival autografts in pterygium surgery: comparison of fibrin glue with sutures.

    PubMed

    Küçükerdönmez, Cem; Karalezli, Aylin; Zengin, Mehmet Ozgur; Akova, Yonca Aydin

    2014-01-01

    To monitor the development of graft vascularization after pterygium excision with conjunctival autograft transplantation (CAT) using indocyanine green angiography (ICGA) and to compare the graft vascularization between 2 different fixation techniques (fibrin glue and sutures). A total of 26 eyes of 26 patients with primary pterygium were randomly assigned after pterygium excision as having either fibrin glue (13 eyes) or Vicryl sutures (13 eyes) for CAT. Anterior segment ICGA findings were evaluated postoperatively at 1, 7, and 15 days and the percentages of graft vascularization in both groups were compared using pixel analysis software program. The mean ± SD age of patients in the suture and fibrin glue groups was 52.1 ± 12.7 years and 57.1 ± 9.82 years, respectively. There was no statistically significant difference between the groups regarding age, sex, or follow-up (p<0.05 for all). Also, the mean intraoperative defect size was not significantly different between the groups, which was measured as 20.11 ± 10.44 mm2 in the suture group and 23.44 ± 12.34 mm2 in the fibrin glue group (p = 0.343). The mean percentage of vascularized graft area at postoperative day 1 and 7 was 18.1 ± 7.8% and 25.3 ± 8.6% in the suture group and 34.8 ± 10.2% and 66.1 ± 17.8% in the fibrin glue group. The difference between the groups was statistically significant (p<0.01 for both). At postoperative day 15, all grafts were 100% perfused in both groups. Fibrin glue fixation of conjunctival autografts led to more vascularization in the early postoperative period than suture fixated grafts, which in turn may have significance in terms of graft health and pterygium recurrence.

  13. Conformations of n-butyl imidazole: matrix isolation infrared and DFT studies.

    PubMed

    Ramanathan, N; Sundararajan, K; Sankaran, K

    2015-03-15

    Conformations of n-butyl imidazole (B-IMID) were studied using matrix isolation infrared spectroscopy by trapping in argon, xenon and nitrogen matrixes using an effusive nozzle source. The experimental studies were supported by DFT computations performed at the B3LYP/6-311++G(d,p) level. Computations identified nine unique minima for B-IMID, corresponding to conformers with tg(±)tt, tg(±)g(∓)t, tg(±)g(±)t, tg(±)tg(±), tg(±)tg(∓), tg(±)g(∓)g(∓), tg(±)g(±)g(±), tg(±)g(∓)g(±) and tg(±)g(±)g(∓) structures, given in order of increasing energy. Computations of the transition state structures connecting the higher energy conformers to the global minimum, tg(±)tt structure were carried out. The barriers for the conformer inter-conversion were found to be ∼2 kcal/mol. Natural Bond Orbital (NBO) analysis was performed to understand the reasons for conformational preferences in B-IMID. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS Inner Detector

    NASA Astrophysics Data System (ADS)

    Poley, L.; Bloch, I.; Edwards, S.; Friedrich, C.; Gregor, I.-M.; Jones, T.; Lacker, H.; Pyatt, S.; Rehnisch, L.; Sperlich, D.; Wilson, J.

    2016-05-01

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive used initially between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). However, this glue has several disadvantages, which motivated the search for an alternative. This paper presents a study of six ultra-violet (UV) cure glues and a glue pad for possible use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, thermal conduction and shear strength. Samples were thermally cycled, radiation hardness and corrosion resistance were also determined. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives than silver loaded glue. Results from electrical tests of first prototype modules constructed using these glues are presented.

  15. URINARY AND AMNIOTIC FLUID LEVELS OF PHTHALATE MONOESTERS IN RATS AFTER THE ORAL ADMINISTRATION OF DI(2-ETHYLHEXYL) PHTHALATE AND DI-N-BUTYL PHTHALATE

    EPA Science Inventory

    Two studies were designed to examine amniotic fluid and maternal urine concentrations of the di(2-ethylhexyl) phthalate (DEHP) metabolite mono(2-ethylhexyl) phthalate (MEHP) and the di-n-butyl phthalate (DBP) metabolite monobutyl phthalate (MBP) after administration of DEHP and D...

  16. Dura covered with fibrin glue reduces adhesions in abdominal wall defects.

    PubMed

    Schier, F; Srour, N; Waldschmidt, J

    1991-12-01

    Dura can greatly facilitate the closure of abdominal wall defects. However, a main disadvantage of its use are the adhesions which develop between omentum, bowel and dura and may lead to bowel obstructions. In this study various groups of rats had either the anterior wall replaced by untreated dura or by dura covered with fibrin glue prior to implantation. Adhesions were found in 75% of sham operated rats, 100% after untreated dura implantation and 50% after the implantation of fibrin glue treated dura.

  17. 40 CFR 180.411 - Fluazifop-P-butyl; tolerances for residues.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... residues of the herbicide, fluazifop-P-butyl, butyl(R)-2-[4-[[5-(trifluoromethyl)-2-pyridinyl]oxy]phenoxy... of the herbicide, fluazifop-P-butyl, butyl(R)-2-[4-[[5-(trifluoromethyl)-2-pyridinyl]oxy]phenoxy...

  18. Biotransformation at 10 C of di-n-butyl phthalate in subsurface microcosms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chauret, C.; Inniss, W.E.; Mayfield, C.I.

    1996-09-01

    Di-n-butyl phthalate (DBP) was found to be transformed by microorganisms under aerobic and anaerobic conditions at 10 C in microcosms simulating the Canadian Forces Base (CFB) Borden subsurface environment. Biotransformation of DBP was observed under aerobic, nitrate-reducing, Fe(III)-reducing, and sulfate-reducing conditions. The biotransformation of DBP in the microcosms was significantly decrease3d as the redox potential was lowered, especially under sulfate-reducing conditions. However, other factors such as nutrient depletion and buildup of toxic intermediates could have affected the biotransformation rates. The highest DBP biotransformation rate (0.57 {micro}g DBP{center_dot}g sediment{sup {minus}1}{center_dot}day{sup {minus}1}) was under sulfate-reducing conditions. Biotransformation of DBP at 10 Cmore » was significantly enhanced by the addition of 10 mM NaNO{sub 3} suggesting that both the addition of nitrate and high redox conditions favor its biotransformation in subsurface environments.« less

  19. APMP.QM-S8: determination of mass fraction of benzoic acid, methyl paraben and n-butyl paraben in soy sauce

    NASA Astrophysics Data System (ADS)

    Teo, Tang Lin; Gui, Ee Mei; Lu, Ting; Sze Cheow, Pui; Giannikopoulou, Panagiota; Kakoulides, Elias; Lampi, Evgenia; Choi, Sik-man; Yip, Yiu-chung; Chan, Pui-kwan; Hui, Sin-kam; Wollinger, Wagner; Carvalho, Lucas J.; Garrido, Bruno C.; Rego, Eliane C. P.; Ahn, Seonghee; Kim, Byungjoo; Li, Xiuqin; Guo, Zhen; Styarini, Dyah; Aristiawan, Yosi; Putri Ramadhaningtyas, Dillani; Aryana, Nurhani; Ebarvia, Benilda S.; Dacuaya, Aaron; Tongson, Alleni; Aganda, Kim Christopher; Junvee Fortune, Thippaya; Tangtrirat, Pradthana; Mungmeechai, Thanarak; Ceyhan Gören, Ahmet; Gündüz, Simay; Yilmaz, Hasibe

    2017-01-01

    The supplementary comparison APMP.QM-S8: determination of mass fraction of benzoic acid, methyl paraben and n-butyl paraben in soy sauce was coordinated by the Health Sciences Authority, Singapore under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM). Ten national metrology institutes (NMIs) or designated institutes (DIs) participated in the comparison. All the institutes participated in the comparison for benzoic acid, while six NMIs/DIs participated in the comparison for methyl paraben and n-butyl paraben. The comparison was designed to enable participating institutes to demonstrate their measurement capabilities in the determination of common preservatives in soy sauce, using procedure(s) that required simple sample preparation and selective detection in the mass fraction range of 50 to 1000 mg/kg. The demonstrated capabilities can be extended to include other polar food preservatives (e.g. sorbic acid, propionic acid and other alkyl benzoates) in water, aqueous-based beverages (e.g. fruit juices, tea extracts, sodas, sports drinks, etc) and aqueous-based condiments (e.g. vinegar, fish sauce, etc). Liquid--liquid extraction and/or dilution were applied, followed by instrumental analyses using LC-MS/MS, LC-MS, GC-MS (with or without derivatisation) or HPLC-DAD. Isotope dilution mass spectrometry was used for quantification, except in the case of a participating institute, where external calibration method was used for quantification of all three measurands. The assigned Supplementary Comparison Reference Values (SCRVs) were the medians of ten results for benzoic acid, six results for methyl paraben and six results for n-butyl paraben. Benzoic acid was assigned a SCRV of 154.55 mg/kg with a combined standard uncertainty of 0.94 mg/kg, methyl paraben was assigned a SCRV of 100.95 mg/kg with a combined standard uncertainty of 0.40 mg/kg, and n-butyl paraben was assigned a SCRV of 99.05 mg

  20. 40 CFR 721.3438 - Chlorohydroxyalkyl butyl ether (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Chlorohydroxyalkyl butyl ether... Specific Chemical Substances § 721.3438 Chlorohydroxyalkyl butyl ether (generic). (a) Chemical substance... chlorohydroxyalkyl butyl ether (PMN P-99-1295) is subject to reporting under this section for the significant new use...

  1. 40 CFR 721.3438 - Chlorohydroxyalkyl butyl ether (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Chlorohydroxyalkyl butyl ether... Specific Chemical Substances § 721.3438 Chlorohydroxyalkyl butyl ether (generic). (a) Chemical substance... chlorohydroxyalkyl butyl ether (PMN P-99-1295) is subject to reporting under this section for the significant new use...

  2. Micronucleus formation and DNA damage in buccal epithelial cells of Indian street boys addicted to gasp 'Golden glue'.

    PubMed

    Mondal, Nandan Kumar; Ghosh, Sreenita; Ray, Manas Ranjan

    2011-04-03

    Genotoxicity of glue sniffing/huffing and tobacco use has been examined in 302 street boys (median age 13 years) and 50 age-matched control school boys who were neither tobacco nor glue users. All the street boys were tobacco users. In addition, 155 were addicted to gasp an industrial adhesive popularly known as 'Golden glue'. Micronucleus (MN) frequency was determined as a measure of chromosomal breakage in exfoliated buccal epithelial cells (BECs) and DNA double strand breaks were quantitatively assessed by counting γ-H2AX foci using immunofluorescence microscopy. Micronucleated cell frequencies (MCFs) in BEC of glue non-addicted (only tobacco) and addicted (tobacco plus glue) street boys were 1.87 ± 1.06‰ and 4.04 ± 2.55‰ respectively, which were significantly higher than that of control (0.32 ± 0.11‰, p<0.0001). Similarly, the numbers γ-H2AX foci in nuclei of BEC were 2.3- and 5.2-times more than control in glue non-addicted and addicted street boys respectively (p<0.0001). Spearman's rank correlation revealed a strong positive association between years of glue addiction with MCFs and γ-H2AX foci numbers, and the association between glue addiction and chromosomal and DNA damage remained positive and significant after controlling income, spending on addiction and loss of appetite as potential confounders in multivariate logistic regression analysis. Thus, addiction to tobacco among the street children in India is associated with chromosomal and DNA damage in BECs and the severity of these changes is significantly increased by the habit of sniffing/huffing of industrial glue. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Crystal structure of (S)-sec-butyl­ammonium l-tartrate monohydrate

    PubMed Central

    Publicover, Ernlie A.; Kolwich, Jennifer; Stack, Darcie L.; Doué, Alyssa J.; Ylijoki, Kai E. O.

    2017-01-01

    The title hydrated mol­ecular salt, C4H12N+·C4H5O6 −·H2O, was prepared by deprotonation of enanti­opure l-tartaric acid with racemic sec-butyl­amine in water. Only one enanti­omer was observed crystallographically, resulting from the combination of (S)-sec-butyl­amine with l-tartaric acid. The sec-butyl­ammonium moiety is disordered over two conformations related by rotation around the CH–CH2 bond; the refined occupancy ratio is 0.68 (1):0.32 (1). In the crystal, mol­ecules are linked through a network of O—H⋯O and N—H⋯O hydrogen-bonding inter­actions, between the ammonium H atoms, the tartrate hy­droxy H atoms, and the inter­stitial water, forming a three-dimensional supra­molecular structure. PMID:28529783

  4. Inhibition of urinary bladder tumors induced by N-butyl-N-(4-hydroxybutyl)-nitrosamine in rats by green tea.

    PubMed

    Sato, D

    1999-02-01

    Recently, the anticarcinogenic effects of green tea have been studied in sites other than the urinary tract. The present study examined the inhibition by green tea of vesical tumors induced in rats by N-butyl-N-(4-hydroxybutyl) nitrosamine (BBN). In the first series of experiments, 0.05% BBN was added to the drinking water of rats and remained present for 5 weeks. In one experiment, six groups of animals received either tap water, green tea, matcha, hojicha, oolong tea or black tea from week 6. In a second experiment, three groups of rats received either tap water, green tea extract or powdered green tea mixed into a pellet diet from week 6. In a third experiment, five groups of rats were fed a pellet diet with addition of either 0, 0.15, 1.5 or 3.0% powdered green tea from week 6. All rats were killed and examined at 40 weeks. Green tea, particularly green tea leaves, dose-dependently inhibited the growth of BBN-induced urinary bladder tumors when given after the carcinogen. Green tea may inhibit bladder tumor growth.

  5. Addressing subjective decision-making inherent in GLUE-based multi-criteria rainfall-runoff model calibration

    NASA Astrophysics Data System (ADS)

    Shafii, Mahyar; Tolson, Bryan; Shawn Matott, L.

    2015-04-01

    GLUE is one of the most commonly used informal methodologies for uncertainty estimation in hydrological modelling. Despite the ease-of-use of GLUE, it involves a number of subjective decisions such as the strategy for identifying the behavioural solutions. This study evaluates the impact of behavioural solution identification strategies in GLUE on the quality of model output uncertainty. Moreover, two new strategies are developed to objectively identify behavioural solutions. The first strategy considers Pareto-based ranking of parameter sets, while the second one is based on ranking the parameter sets based on an aggregated criterion. The proposed strategies, as well as the traditional strategies in the literature, are evaluated with respect to reliability (coverage of observations by the envelope of model outcomes) and sharpness (width of the envelope of model outcomes) in different numerical experiments. These experiments include multi-criteria calibration and uncertainty estimation of three rainfall-runoff models with different number of parameters. To demonstrate the importance of behavioural solution identification strategy more appropriately, GLUE is also compared with two other informal multi-criteria calibration and uncertainty estimation methods (Pareto optimization and DDS-AU). The results show that the model output uncertainty varies with the behavioural solution identification strategy, and furthermore, a robust GLUE implementation would require considering multiple behavioural solution identification strategies and choosing the one that generates the desired balance between sharpness and reliability. The proposed objective strategies prove to be the best options in most of the case studies investigated in this research. Implementing such an approach for a high-dimensional calibration problem enables GLUE to generate robust results in comparison with Pareto optimization and DDS-AU.

  6. Amplitude of Glottal Mucosal Wave After Vocal Fold Microflap With or Without Fibrin Glue.

    PubMed

    González-Herranz, Ramón; Amarillo, Elizabeth; Hernández-García, Estefanía; Montojo Woodeson, José; Plaza-Mayor, Guillermo

    2017-05-01

    The vocal fold microflap technique is the ideal to remove benign vocal fold pathology. Our objective is to compare the amplitudes of the mucosal wave before and after the closure of microflap defect with fibrin glue, and when microflap is left to heal by secondary intention. The present study is a retrospective series, including 32 patients treated by intracordal phonosurgery, with closure of the microflap either with fibrin glue or by healing by secondary intention. They all had both preoperative and 6-month postoperative track records to allow voice analysis, a subjective Voice Handicap Index 10 (VHI-10), and a good image quality strobe. After selecting the patients was found that the mean overall preoperative VHI-10 was 26.6, and improved up to 10.5 after surgery, a statistical differences (P = 0.03). When comparing both groups, with or without fibrin glue, fibrin glue did not improved results in VHI-10. On the contrary, there was a significant difference in the improvement of the open glottal phase after surgery (P = 0.03), showing a much higher improvement when fibrin glue was used. The use of fibrin glue after a vocal fold microflap for advanced pathology, such as sulcus vocalis in pocket, vergeture, or vocal fold scar, increases the amplitude of the mucosal wave of the vocal folds, but does not improve the VHI-10 results in our cohort of female patients. So far, patient-reported outcome shows that healing by secondary intention continues to provide excellent voice results. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  7. Patch-test reactions to plastic and glue allergens.

    PubMed

    Kanerva, L; Jolanki, R; Alanko, K; Estlander, T

    1999-07-01

    Plastics and glues are common causes of occupational dermatoses, but only few reports have dealt with patch-test reactions caused by plastic and glue allergens. Patients exposed to plastics and remitted to an occupational dermatology clinic, were patch-tested with 50-53 plastic and glue allergens during a 6-year period. Conventional patch-test techniques were used. The most common causes of allergic patch-test reactions in 360 patients were novolac epoxy resin (5.1%), phenol formaldehyde resin (3.1%), 4-tert-butylcatechol (2.6%), phenyl glycidyl ether (2.6%), diaminodiphenyl methane (2.2%), benzoyl peroxide (2.2%), hexamethylene tetramine (2.0%) and o-cresyl glycidyl ether (1.6%). The allergens that most often elicited irritant patch-test reactions were: benzoyl peroxide (9.5%), abitol alcohol (3.6%), hydroquinone (3.1%), acid-catalyzed phenol formaldehyde resin (2.5%) and toluene diisocyanate (1.9%). Twenty-six out of 53 chemicals caused no allergic reaction during the 6-year period. Plastic allergens in the standard series provoked allergic reactions with formaldehyde (5.8%), diglycidyl ether of bisphenol A (3.2%), 4-tert-butylphenol-formaldehyde-resin (1.1%), toluene sulphonamide formaldehyde-resin (1.1%) and triethylenglycol diacrylate (0.4%). Although half of the plastic chemicals gave no allergic patch-test reactions during a 6-year period, with unusual allergens this low yield needs to be accepted, because otherwise rare allergies will not be detected. Also a negative reaction has diagnostic value.

  8. Molecular dynamics simulations of n-hexane at 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lisal, Martin; Department of Physics, Faculty of Science, J. E. Purkinje University, 400 96 Usti n. Lab.; Izak, Pavel

    Molecular dynamics simulations of n-hexane adsorbed onto the interface of 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide ([bmim][Tf{sub 2}N]) are performed at three n-hexane surface densities, ranged from 0.7 to 2.3 {mu}mol/m{sup 2} at 300 K. For [bmim][Tf{sub 2}N] room-temperature ionic liquid, we use a non-polarizable all-atom force field with the partial atomic charges based on ab initio calculations for the isolated ion pair. The net charges of the ions are {+-}0.89e, which mimics the anion to cation charge transfer and polarization effects. The OPLS-AA force field is employed for modeling of n-hexane. The surface tension is computed using the mechanical route and itsmore » value decreases with increase of the n-hexane surface density. The [bmim][Tf{sub 2}N]/n-hexane interface is analyzed using the intrinsic method, and the structural and dynamic properties of the interfacial, sub-interfacial, and central layers are computed. We determine the surface roughness, global and intrinsic density profiles, and orientation ordering of the molecules to describe the structure of the interface. We further compute the survival probability, normal and lateral self-diffusion coefficients, and re-orientation correlation functions to elucidate the effects of n-hexane on dynamics of the cations and anions in the layers.« less

  9. Molecular dynamics simulations of n-hexane at 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide interface.

    PubMed

    Lísal, Martin; Izák, Pavel

    2013-07-07

    Molecular dynamics simulations of n-hexane adsorbed onto the interface of 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide ([bmim][Tf2N]) are performed at three n-hexane surface densities, ranged from 0.7 to 2.3 μmol/m(2) at 300 K. For [bmim][Tf2N] room-temperature ionic liquid, we use a non-polarizable all-atom force field with the partial atomic charges based on ab initio calculations for the isolated ion pair. The net charges of the ions are ±0.89e, which mimics the anion to cation charge transfer and polarization effects. The OPLS-AA force field is employed for modeling of n-hexane. The surface tension is computed using the mechanical route and its value decreases with increase of the n-hexane surface density. The [bmim][Tf2N]/n-hexane interface is analyzed using the intrinsic method, and the structural and dynamic properties of the interfacial, sub-interfacial, and central layers are computed. We determine the surface roughness, global and intrinsic density profiles, and orientation ordering of the molecules to describe the structure of the interface. We further compute the survival probability, normal and lateral self-diffusion coefficients, and re-orientation correlation functions to elucidate the effects of n-hexane on dynamics of the cations and anions in the layers.

  10. Comparison of self-made cryopreservative fibrin glue and commercial fibrin glue kit in pterygium surgery: 1-year follow-up.

    PubMed

    Gong, Jingwen; Fan, Jiaqi; Shen, Ting; Jiang, Jin

    2018-03-01

    To assess long-term efficacy and safety of self-made cryopreservative fibrin glue (SMC) applied in pterygium surgery. Prospective, comparative, interventional case series. Forty eyes of 40 patients with nasal primary pterygium, 24 male and 16 female, were enrolled. The patients were assigned to two groups and each contained 12 male and eight female based on the pterygium area encroaching onto the cornea. In one group, the conjunctival autograft was attached to the sclera with SMC stored for 2 months, and in the other group, commercial fibrin glue kit (CK) was applied after the pterygium was removed. All the patients were followed up postoperatively on days 1, 3, 7 and 14 then at months 1, 3, 6, 12. The main outcome measures included operating time, postoperative discomfort, recurrence rate and complications. There were no significant differences in surgery time (p = 0.713) and postoperative discomfort (day 1, 3, 7; p = 0.747, p = 0.766, p = 0.983, respectively) between the two groups. By the end of 1-year follow-up, the recurrence rate was 0% in the SMC group and 5% in the CK group (p = 1.000). There were no infections and severe visual acuity (VA) threatening complications in either group. Self-made cryopreservative fibrin glue (SMC) is as effective as standard CK for autograft fixation in pterygium surgery and it also has good safety after long-term follow-up. For its convenience and low cost, this new methods should be popularized, especially in underdeveloped area. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  11. Natural healing-inspired collagen-targeting surgical protein glue for accelerated scarless skin regeneration.

    PubMed

    Jeon, Eun Young; Choi, Bong-Hyuk; Jung, Dooyup; Hwang, Byeong Hee; Cha, Hyung Joon

    2017-07-01

    Skin scarring after deep dermal injuries is a major clinical problem due to the current therapies limited to established scars with poor understanding of healing mechanisms. From investigation of aberrations within the extracellular matrix involved in pathophysiologic scarring, it was revealed that one of the main factors responsible for impaired healing is abnormal collagen reorganization. Here, inspired by the fundamental roles of decorin, a collagen-targeting proteoglycan, in collagen remodeling, we created a scar-preventive collagen-targeting glue consisting of a newly designed collagen-binding mussel adhesive protein and a specific glycosaminoglycan. The collagen-targeting glue specifically bound to type I collagen in a dose-dependent manner and regulated the rate and the degree of fibrillogenesis. In a rat skin excisional model, the collagen-targeting glue successfully accelerated initial wound regeneration as defined by effective reepithelialization, neovascularization, and rapid collagen synthesis. Moreover, the improved dermal collagen architecture was demonstrated by uniform size of collagen fibrils, their regular packing, and a restoration of healthy tissue component. Collectively, our natural healing-inspired collagen-targeting glue may be a promising therapeutic option for improving the healing rate with high-quality and effective scar inhibition. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Rapid corneal thinning and perforated ulcerative keratitis in a patient with relapsing polychondritis.

    PubMed

    Lai, Tracy Hiu Ting; Far, Nikki; Young, Alvin Lerrmann; Jhanji, Vishal

    2017-01-01

    To report rapid corneal thinning and perforation in a case with relapsing polychondritis. A 43 year-old male diagnosed with relapsing polychondritis suffered from bilateral scleritis, bilateral swelling of pinna, saddle nose and tracheal stenosis. The patient presented with right eye pain and redness for one month. Slit lamp examination of the right eye showed 80% peripheral corneal thinning between 3 and 7 o'clock. The best-corrected visual acuity (BCVA) was 1.0 bilaterally. The degree of corneal thinning worsened to 90% after one week of oral corticosteroid use. Subsequently, topical cyclosporine 2% eye drops four times a day, oral doxycycline 100 mg twice a day and oral vitamin C 2 g daily were added. The corneal thinning gradually improved to about 60%. However, the patient rapidly tapered oral prednisolone against medical advice and returned with an acute drop in vision in his right eye. Slit lamp examination of the right eye showed peripheral corneal perforation with iris prolapse. An emergency repair with cyanoacrylate glue was performed. Intravenous methylprednisolone 1 mg/kg body weight was administered for three days and 1 g/day intravenous immunoglobulin was administered every four weeks. At 3 months postoperatively, BCVA in the right eye was 0.6. Slit lamp examination showed a well-formed anterior chamber with glue in situ. Relapsing polychondritis may be associated with rapid corneal thinning. The clinicians should be aware of the possibility of corneal perforation in these cases. Cyanoacrylate glue is a viable temporary management option in such scenarios.

  13. Efficacy of bubaline fibrin glue on full-thickness pinch and punch skin grafting in a pig.

    PubMed

    Dejyong, Krittee; Kaewamatawong, Theerayuth; Brikshavana, Pasakorn; Durongphongtorn, Sumit

    2017-03-01

    Fibrin glue, which is formed from the action of thrombin (a serine protease) on fibrinogen, has been developed for use as an adhesive to increase the success of skin graft surgery. The objective of this study was to evaluate if bubaline fibrin glue would promote skin graft survival in pigs. The grafting was divided into two steps. First, granulation wound preparation was performed in a healthy swine by creating four full-skin depth wounds (3 × 12 cm 2 ) at the dorsal part of the loin area on each side. Second, pinch and punch skin grafting, where eight skin discs (0.6 cm diameter) were regularly placed (0.6 cm distance apart) in the granulation tissue bed of each wound, was performed 5 days later. The bubaline fibrin glue was added prior to application of the 16 skin graft discs in two of the wounds, while no glue was added to the other 16 skin graft discs in the other two wounds. The number of surviving graft pieces and histological examination was evaluated after 3, 7, and 14 days post-operation and compared by pairing between the control and the bubaline fibrin glue groups. The number of grafts that remained at 3 and 7 days post-operation and the number of new microvessels at 3 days post-operation were significantly higher ( p < 0.05) in the bubaline fibrin glue group than in the control group. However, there was no significant difference in the number of fibroblasts, the intensity of scarring and the intensity of inflammation between the two groups, except for the significantly lower intensity of inflammation at 7 days post-operation in the bubaline fibrin glue group. In conclusion, bubaline fibrin glue has the advantage of decreasing the skin graft loss by approximately 31.3-37.5% compared with the control group and also promotes angiogenesis.

  14. Refreshing the Aged Latent Fingerprints with Ionizing Radiation Prior to the Cyanoacrylate Fuming Procedure: A Preliminary Study.

    PubMed

    Ristova, Mimoza M; Radiceska, Pavlina; Bozinov, Igorco; Barandovski, Lambe

    2016-05-01

    One of the crucial factors determining the cyanoacrylate deposit quality over latent fingerprints appeared to be the extent of the humidity. This work focuses on the enhancement/refreshment of age-degraded latent fingerprints by irradiating the samples with UV, X-ray, or thermal neutrons prior to the cyanoacrylate (CA) fuming. Age degradation of latent fingerprints deposited on glass surfaces was examined through the decrease in the number of characteristic minutiae counts over time. A term "critical day" was introduced for the time at which the average number of identifiable minutiae definitions drops to one-half. Fingerprints older than their "critical day" were exposed to either UV, X-ray, or thermal neutrons. Identical reference samples were kept unexposed. All samples, both reference and irradiated, were developed during a single CA fuming procedure. Comparative latent fingerprint analysis showed that exposure to ionizing radiation enhances the CA fuming, yielding a 20-30% increase in average minutiae count. © 2015 American Academy of Forensic Sciences.

  15. Di-tert-butyl­chlorido(N,N-dibenzyl­dithio­carbamato)tin(IV)

    PubMed Central

    Abdul Muthalib, Amirah Faizah; Baba, Ibrahim; Mohamed Tahir, Mohamed Ibrahim; Tiekink, Edward R. T.

    2011-01-01

    The SnIV atom in the title diorganotin dithio­carbamate, [Sn(C4H9)2(C15H14NS2)Cl], is penta­coordinated by an asymmetrically coordinating dithio­carbamate ligand, a Cl atom and two C atoms of the Sn-bound tert-butyl groups. The resulting C2ClS2 donor set defines a coordination geometry inter­mediate between square pyramidal and trigonal bipyramidal with a slight tendency towards the former. PMID:21522304

  16. Bandwidth-Tunable Fiber Bragg Gratings Based on UV Glue Technique

    NASA Astrophysics Data System (ADS)

    Fu, Ming-Yue; Liu, Wen-Feng; Chen, Hsin-Tsang; Chuang, Chia-Wei; Bor, Sheau-Shong; Tien, Chuen-Lin

    2007-07-01

    In this study, we have demonstrated that a uniform fiber Bragg grating (FBG) can be transformed into a chirped fiber grating by a simple UV glue adhesive technique without shifting the reflection band with respect to the center wavelength of the FBG. The technique is based on the induced strain of an FBG due to the UV glue adhesive force on the fiber surface that causes a grating period variation and an effective index change. This technique can provide a fast and simple method of obtaining the required chirp value of a grating for applications in the dispersion compensators, gain flattening in erbium-doped fiber amplifiers (EDFAs) or optical filters.

  17. Photo-crosslinkable cyanoacrylate bioadhesive: shrinkage kinetics, dynamic mechanical properties, and biocompatibility of adhesives containing TMPTMA and POSS nanostructures as crosslinking agents.

    PubMed

    Ghasaban, S; Atai, M; Imani, M; Zandi, M; Shokrgozar, M-A

    2011-11-01

    The study investigates the photo-polymerization shrinkage behavior, dynamic mechanical properties, and biocompatibility of cyanoacrylate bioadhesives containing POSS nanostructures and TMPTMA as crosslinking agents. Adhesives containing 2-octyl cyanoacrylate (2-OCA) and different percentages of POSS nanostructures and TMPTMA as crosslinking agents were prepared. The 1-phenyl-1, 2-propanedione (PPD) was incorporated as photo-initiator into the adhesive in 1.5, 3, and 4 wt %. The shrinkage strain of the specimens was measured using bonded-disk technique. Shrinkage strain, shrinkage strain rate, maximum and time at maximum shrinkage strain rate were measured and compared. Mechanical properties of the adhesives were also studied using dynamic mechanical thermal analysis (DMTA). Biocompatibility of the adhesives was examined by MTT method. The results showed that shrinkage strain increased with increasing the initiator concentration up to 3 wt % in POSS-containing and 1.5 wt % in TMPTMA-containing specimens and plateaued out at higher concentrations. By increasing the crosslinking agent, shrinkage strain, and shrinkage strain rate increased and the time at maximum shrinkage strain rate decreased. The study indicates that the incorporation of crosslinking agents into the cyanoacrylate adhesives resulted in improved mechanical properties. Preliminary MTT studies also revealed better biocompatibility profile for the adhesives containing crosslinking agents comparing to the neat specimens. Copyright © 2011 Wiley Periodicals, Inc.

  18. Emergency wounds treated with cyanoacrylate and long-term results in pediatrics: a series of cases; what are the advantages and boards?

    PubMed Central

    Gulalp, Betul; Seyhan, Tamer; Gursoy, Sonnur; Altinors, M Nur

    2009-01-01

    Background Ethyl-2-cyanoacrylate (ECA) is a tissue adhesive material applied to close superficial wounds. The aim of this study was to explore the benefits of cyanoacrylates in the emergency department in children with current application with regard to cost-effectiveness, satisfaction and long follow up. Findings Patients were treated after assignment of the consent with an explanation by the relatives in a tertiary emergency department (ED), 2007. The evaluation was based on different superficial wound repairs due to blunt trauma within a 2-hour time period (<6 hours), and small wounds (≤3 cm). These wounds were cleansed with serum sale and then dried with gauze. Wound repairs were observed for six months in order to observe the tissue changes. The patient's age, sex, indication, application time, pain score, cost, additional tending (if needed), complications, and cosmetic satisfaction were recorded. A total of 9 patients were evaluated and followed for 6 months. Except for one, all children were treated without any serious complications. ECA was cost-effective, time-saving, and provided successful repair satisfaction by a blinded plastic surgeon and patient/parents. Conclusion This report displayed the pediatric effective use of cyanoacrylates, even in non- traditional repairs in the emergency departments. PMID:19594954

  19. [Propolis. The bee glue as presented by the Graeco-Roman literature].

    PubMed

    Golder, Werner

    2004-01-01

    The bee glue, commonly known as propolis, has been employed for medical purposes already in teh ancient world. More than 15 Greek and Roman authors report on the preparation and application of the so-called third natural product of the bees (besides honey and wax). Aristoteles described the fundamental issues of its biology in his 'Historia Animalium' correctly. The bulk of propolis is obtained from the barks of poplars. Once carried in the hives, the glue is used to stabilize the cells and honeycombs and to protect the bees against invaders and cold weather. Propolis has been chiefly employed for the preparation of ointment and plasters. For this purpose, the viscous raw material was purified, moulded and boiled. In most preparations, the bee glue was only one of many (up to 20) pharmacologically active constituents and came to five to 20% of the mixture. Only rarely, a single drug therapy was using propolis was carried out. The application of the glue was most successful in general surgery and casualties. In that respect, the ancient physicians took advantage of the anti-edematous and anti-infectious properties of the substance. Thus, it was used to treat bumps, indurations, and slow-healing wounds. Moreover, cataplasms against swollen cervical nodes and indurations of the female breast often contained propolis. Finally, bee glue proved successful for the treatment of chronic backache and pain in the hip as well as fresh injuries of muscles and tendons. In the sector of skin diseases, lichens and condylomata were found to respond well to propolis. ALl this indications have been a matter of several records. However, the successful use of propolis in diseases of the stomach and liver has ben reported solely by Alexander of Tralles (6th century AD). Not counting the internal diseases, the spectrum of indications for propolis has not substantially changed as compared to the classical antiquity. Interestingly, radiation therapists have adopted the ancient remedy and

  20. Sclerosant extravasation as a complication of sclerosing endotherapy for bleeding gastric varices.

    PubMed

    Cheng, H-C; Cheng, P-N; Tsai, Y-M; Tsai, H-M; Chen, C-Y

    2004-03-01

    We report here the case of a 65-year-old woman who suffered intraperitoneal sclerosant leakage after endoscopic injection sclerotherapy for bleeding gastric varices. In total, 3 ml of N-butyl-2-cyanoacrylate and Lipiodol mixture was injected. The patient developed mild fever and pain over the left upper quadrant and flank after the procedure. In addition to a Lipiodol-filled gastric varix, the imaging studies disclosed a wide spread of Lipiodol over the left peritoneal cavity. The patient was kept fasting with parenteral antibiotics and nutrition. She responded well to the treatment, and all of the symptoms had subsided 6 days later.

  1. Enantioselective behaviour of the herbicide fluazifop-butyl in vegetables and soil.

    PubMed

    Qi, Yanli; Liu, Donghui; Liu, Chang; Liang, Yiran; Zhan, Jing; Zhou, Zhiqiang; Wang, Peng

    2017-04-15

    The enantioselective dissipation of the enantiomers of fluazifop-butyl in tomato, cucumber, pakchoi, rape and soil under field condition was investigated to elucidate the enantioselective environmental behaviours and chiral stability of the optical pure product. Fluazifop, the major chiral metabolite of fluazifop-butyl, was also detected. Fluazifop-butyl dissipated rapidly in the vegetables and soil with the half-lives of the enantiomers ranging from 1.62 to 2.84days. Enantioselective degradations of fluazifop-butyl were found. In tomato and cucumber, S-fluazifop-butyl dissipated faster than R-enantiomer, while R-fluazifop-butyl showed a faster degradation in pakchoi, rape and soil. Fluazifop was found almost immediately after the application of fluazifop-butyl and had relatively longer persistent time. When the optical pure product fluazifop-P-butyl was applied, rapid degradation to R-fluazifop was found with half-lives from 1.24 to 2.28days, and no S-fluazifop-butyl or S-fluazifop was detected showing the herbicidally active fluazifop-P-butyl and R-fluazifop were configurationally stable. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Nuclear Magnetic Resonance Shift Reagents: Abnormal 13C Shifts Produced by Complexation of Lanthanide Chelates with Saturated Amines and n-Butyl Isocyanide

    PubMed Central

    Marzin, Claude; Leibfritz, Dieter; Hawkes, Geoffrey E.; Roberts, John D.

    1973-01-01

    Lanthanide-induced shfits of 13C nuclear magnetic resonances are reported for several amines and n-butyl isocyanide. Contact contributions to such shifts, especially of β carbons, are clearly important for the chelates of Eu+3 and Pr+3. The importance of contact terms is shown to change in a rather predictable manner with the structure of the amine. PMID:16592062

  3. Amended final report on the safety assessment of PPG-40 butyl ether with an addendum to include PPG-2, -4, -5, -9, -12, -14, -15, -16, -17, -18, -20, -22, -24, -26, -30, -33, -52, and -53 butyl ethers.

    PubMed

    Lanigan, R S

    2001-01-01

    The Polypropylene Glycol (PPG) Butyl Ethers function as skinand hair-conditioning agents in cosmetics. Intestinal absorption of the PPG Butyl Ethers was inversely proportional to the molecular weight. In general, the toxicity of the PPG Butyl Ethers decreased as the molecular weight increased. In acute studies, moderate intraperitoneal (IP) doses of various PPG Butyl Ethers caused convulsive seizures in mice and anesthetized dogs, and large oral doses caused decreased activity, anuria, renal tubular swelling and necrosis, and hepatic swelling and necrosis. PPG-2 Butyl Ether vapors were nontoxic by the inhalation route. PPG-2 Butyl Ether was nontoxic in short-term feeding and dermal exposure studies in rats. In animal irritation studies, PPG-2 Butyl Ether caused minor, transient erythema and desquamation; in addition, erythema, edema, ecchymosis, necrosis, and other changes were observed during an acute percutaneous study. PPG-2 Butyl Ether also caused minor to moderate conjunctival irritation and minor corneal injury. PPG-2 Butyl Ether when dermally applied was nontoxic to pregnant rats and was nonteratogenic at doses up to 1.0 ml/kg/day. PPG BE800 at concentrations of 0.001% to 0.26% in feed was noncarcinogenic to rats after 2 years of treatment. In clinical studies, PPG BE800 was nonirritating and nonsensitizing to the skin when tested using 200 subjects. PPG-40 Butyl Ether was neither an irritant nor a sensitizer in a repeat-insult patch test using 112 subjects. Although clinical testing did not indicate significant skin irritation is produced by these ingredients, the animal test data did indicate the potential that these ingredients can be irritating. Therefore, it was concluded that the PPG Butyl Ethers can be used safely in cosmetic products if they are formulated to avoid irritation. Data on the component ingredients, Propylene Glycol, PPG, and n-Butyl Alcohol, from previous cosmetic ingredient safety assessments were also considered and found to support

  4. Tissue glue in sutureless vitreoretinal surgery for the treatment of wound leakage.

    PubMed

    Batman, Cosar; Ozdamar, Yasemin; Aslan, Ozlem; Sonmez, Kenan; Mutevelli, Seda; Zilelioglu, Guler

    2008-01-01

    To assess the surgical outcomes of the use of tissue glue to close sclerotomy sites when required and the views of ultrasound biomicroscopy of the sclerotomy sites in 23- and 25-gauge vitrectomy systems. A 25-gauge transconjunctival sutureless vitrectomy was performed in 38 eyes and a 23-gauge transconjunctival sutureless vitrectomy was performed in 46 eyes for various vitreoretinal diseases. Wound leakage occurred at the sclerotomy sites at the end of the surgery in 6 eyes with 23-gauge transconjunctival sutureless vitrectomy and 7 eyes with 25-gauge transconjunctival sutureless vitrectomy. The sclerotomy sites were closed by using tissue glue to prevent wound leakage and evaluated with ultrasound biomicroscopy postoperatively. No wound leakage was observed at the end of the surgical procedure or during the follow-up period. Abnormal fibrous ingrowth was not detected at the sclerotomy sites by means of ultrasound biomicroscopy. The results demonstrated the efficacy of tissue glue for closing site ports when wound leakage is observed in transconjunctival sutureless vitreoretinal surgery.

  5. Can Sericin Prove Useful as a Pleurodesis Agent or Tissue Glue?

    PubMed

    Yazicioglu, Alkin; Demirag, Funda; Alici, Ibrahim Onur; Yekeler, Erdal; Karaoglanoglu, Nurettin

    2017-08-01

    Background  Sericin is a natural, gum-like, macromolecule protein, synthesized from silkworms for the formation of cocoon shells. The aim of the present study is to describe the effects of sericin when used for pleurodesis and/or as tissue glue. Methods  Adult, male, 12-week-old Wistar albino rats, weighing 257 to 395 g were used in the present study ( n  = 12). The animals were randomly divided into two equal groups as the sericin and the control group. After intramuscular administration of the anesthetic agent, the rats were intubated and mechanically ventilated. A left thoracotomy was performed and 30 mg sericin powder was instilled into the thoraxes of the sericin group. The remaining rats were allocated to a sham thoracotomy group. The animals were housed in individual cages, fed ad-libitum, and sacrificed 8 days after. After sacrifice, the left hemithoraxes were removed en bloc and underwent histopathologic examination. Results  Masson trichrome staining was applied on the visceral pleura sections of all the animals. Each animal specimen ( n  = 6, 100%) in the control group showed minimal collagen deposition, while only one rat (16.67%) in the sericin group had minimal collagen deposition. However, in the sericin group, five animals (83.33%) showed dense collagen deposition, fibroblastic activity, and fibrosis. According to the test method, independent t -test, developing fibroblastic activity and fibrosis are statistically significant between the two groups ( p  < 0.01). There were no foreign-body reactions and no evidence of biological glue on the specimens in the sericin group. The rats in the sericin group had lower inflammatory reactions compared with those in the control group. Emphysema was observed in two rats (33.33%) in the sericin group and in four rats (66.67%) in the control group. Therefore, sericin was found to be associated with an increase in fibroblastic activity and fibrosis in visceral pleura without exerting any

  6. Collagen-Immobilized Lipases Show Good Activity and Reusability for Butyl Butyrate Synthesis.

    PubMed

    Dewei, Song; Min, Chen; Haiming, Cheng

    2016-11-01

    Candida rugosa lipases were immobilized onto collagen fibers through glutaraldehyde cross-linking method. The immobilization process has been optimized. Under the optimal immobilization conditions, the activity of the collagen-immobilized lipase reached 340 U/g. The activity was recovered of 28.3 % by immobilization. The operational stability of the obtained collagen-immobilized lipase for hydrolysis of olive oil emulsion was determined. The collagen-immobilized lipase showed good tolerance to temperature and pH variations in comparison to free lipase. The collagen-immobilized lipase was also applied as biocatalyst for synthesis of butyl butyrate from butyric acid and 1-butanol in n-hexane. The conversion yield was 94 % at the optimal conditions. Of its initial activity, 64 % was retained after 5 cycles for synthesizing butyl butyrate in n-hexane.

  7. In situ synthesis of di-n-butyl l-tartrate-boric acid complex chiral selector and its application in chiral microemulsion electrokinetic chromatography.

    PubMed

    Hu, Shaoqiang; Chen, Yonglei; Zhu, Huadong; Zhu, Jinhua; Yan, Na; Chen, Xingguo

    2009-11-06

    A novel procedure for in situ assembling a complex chiral selector, di-n-butyl l-tartrate-boric acid complex, by the reaction of di-n-butyl l-tartrate with boric acid in a running buffer was reported and its application in the enantioseparation of beta-blockers and structural related compounds by chiral microemulsion electrokinetic chromatography (MEEKC) has been demonstrated. In order to achieve a good enantioseparation, the effect of dibutyl l-tartrate and sodium tetraborate concentration, surfactant identity and concentration, cosurfactant, buffer pH and composition, organic modifiers, as well as applied voltage and capillary length were investigated. Ten pairs of enantiomers that could not be separated with only dibutyl l-tartrate, obtained good chiral separation using the complex chiral selector; among them, seven pairs could be baseline resolved under optimized experimental conditions. The fixation of chiral centers by the formation of five-membered rings, and being oppositely charged with basic analytes were thought to be the key factors giving the complex chiral selector a superior chiral recognition capability. The effect of the molecular structure of analytes on enantioseparation was discussed in terms of molecular interaction.

  8. Morphological, elemental, and optical characterization of plasma polymerized n-butyl methacrylate thin films

    NASA Astrophysics Data System (ADS)

    Nasrin, Rahima; Hossain, Khandker S.; Bhuiyan, A. H.

    2018-05-01

    Plasma polymerized n-butyl methacrylate (PPnBMA) thin films of varying thicknesses were prepared at room temperature by AC plasma polymerization system using a capacitively coupled parallel plate reactor. Field-emission scanning electron microscopy (FESEM), atomic force microscopy (AFM), energy-dispersive X-ray (EDX) analysis, and ultraviolet-visible (UV-Vis) spectroscopic investigation have been performed to study the morphological, elemental, and optical properties of the PPnBMA thin films, respectively. The flat and defect-free nature of thin films were confirmed by FESEM and AFM images. With declining plasma power, average roughness and root mean square roughness increase. Allowed direct transition ( E gd) and indirect transition ( E gi) energy gaps were found to be 3.64-3.80 and 3.38-3.45 eV, respectively, for PPnBMA thin films of different thicknesses. Values of E gd as well as E gi increase with the increase of thickness. The extinction coefficient, Urbach energy, and steepness parameter were also determined for these thin films.

  9. Impetigo herpetiformis occurring during N-butyl-scopolammonium bromide therapy in pregnancy: case report.

    PubMed

    Guerriero, C; Lanza Silveri, S; Sisto, T; Rosati, D; De Simone, C; Fossati, B; Pomini, F; Rotoli, M; Amerio, P; Capizzi, R

    2008-01-01

    Impetigo herpetiformis (IH) is a rare dermatosis arising during the third trimester of pregnancy which is generally considered as a form of pustular psoriasis of unknown aetiology. Clinically it is characterized by erythematous plaques surrounded by sterile pustules associated with fever, diarrhea, sweating and increasing risk of stillbirth for placental insufficiency. We describe a case of developed erythematous plaques surrounded by pustules localised initially to the trunk of a 35-year-old woman at the 34th week of gestation after 5 days of treatment with N-Butyl-Scopolammonium, and which later involved the upper and lower limbs. Skin histology confirmed the diagnosis of generalised pregnancy pustular psoriasis (impetigo herpetiformis). IH is reported to be associated with hypocalcemia, hypoparathyroidism, use of oral contraceptives and bacterial infections. This is the first report suggesting the potential role of drugs other than oral contraceptives in the pathogenetic mechanism of this disease. In this case an adverse cutaneous reaction to BB could be the cause of the development of Koebner isomorphism.

  10. Effects of cyanoacrylate fuming, time after recovery, and location of biological material on the recovery and analysis of DNA from post-blast pipe bomb fragments*.

    PubMed

    Bille, Todd W; Cromartie, Carter; Farr, Matthew

    2009-09-01

    This study investigated the effects of time, cyanoacrylate fuming, and location of the biological material on DNA analysis of post-blast pipe bomb fragments. Multiple aliquots of a cell suspension (prepared by soaking buccal swabs in water) were deposited on components of the devices prior to assembly. The pipe bombs were then deflagrated and the fragments recovered. Fragments from half of the devices were cyanoacrylate fumed. The cell spots on the fragments were swabbed and polymerase chain reaction/short tandem repeat analysis was performed 1 week and 3 months after deflagration. A significant decrease in the amount of DNA recovered was observed between samples collected and analyzed within 1 week compared with the samples collected and analyzed 3 months after deflagration. Cyanoacrylate fuming did not have a measurable effect on the success of the DNA analysis at either time point. Greater quantities of DNA were recovered from the pipe nipples than the end caps. Undeflagrated controls showed that the majority (>95%) of the DNA deposited on the devices was not recovered at a week or 3 months.

  11. Endoscopic treatment with fibrin glue of post-intubation tracheal laceration

    PubMed Central

    Cascone, Roberto; Di Natale, Davide; Pierdiluca, Matteo; Mastromarino, Rossella; Natale, Giovanni; De Ruberto, Emanuele; Messina, Gaetana; Vicidomini, Giovanni; Santini, Mario

    2017-01-01

    Post-intubation tracheal laceration (PITL) is a rare and potential life-threatening condition requiring prompt diagnosis and treatment. A conservative treatment is indicated in patients with laceration <2 cm in length while surgery is the treatment of choice for laceration >4 cm. For laceration between 2–4 cm, the best treatment is debate; some authors recommend surgery while others do not definitely exclude endoscopic treatment. Herein, we reported the endoscopic treatment with fibrin glue of PITL. The procedure is performed using a standard video-bronchoscopy in operating room; the patient is in spontaneous breathing and deep sedation. After identification of tracheal laceration, the fibrin glue is injected through a dedicated double lumen catheter into the lesion. After mixing both components of fibrin glue, polymerization of fibrin occurs resulting in an elastic and opaque clot that closes the lesion. The key success of the procedure is based on accurate patient selection. Patients are eligible if (I) they are clinically stable and in spontaneous respiration; (II) with a small and superficial tracheal laceration (≤4 cm in length and without oesophageal injury); (III) localized at level of the upper or middle trachea; and (IV) without clinical and/or radiological signs of mediastinal collection, of emphysema or pneumomediastinum progression, and of infection. PMID:29078663

  12. Methemoglobin formation from butylated hydroxyanisole and oxyhemoglobin. Comparison with butylated hydroxytoluene and p-hydroxyanisole.

    PubMed

    Stolze, K; Nohl, H

    1992-01-01

    The widely used food additives butylated hydroxyanisole (BHA) and butylated hydroxytoluene (BHT) react with oxyhemoglobin, thereby forming methemoglobin. The reaction rates were measured using visible spectroscopy, and second order rate constants were established for BHA and compared with p-hydroxyanisole. Using ESR we investigated the involvement of free radical reaction intermediates. The expected one-electron oxidation product of BHA and BHT, the phenoxyl radical, could only be detected with pure 3-t-butyl-4-hydroxyanisole and oxyhemoglobin. With the commercial mixture of 2- and 3-t-butyl-4-hydroxyanisole a very strong ESR signal of a secondary free radical species was observed, similar to the one observed earlier with p-hydroxyanisole and dependent on the presence of free thiol groups, so that we assumed the intermediate existence of a perferryl species, the MetHb-H2O2 adduct. In a second series of experiments we investigated the reactivity of this postulated intermediate with BHA and BHT, starting with a pure MetHb/H2O2-phenol mixture in a stopped-flow apparatus linked to the ESR spectrometer, detecting the expected phenoxyl radicals from BHA and p-hydroxyanisole. Due to the low solubility and decreased reactivity of BHT only traces of phenoxyl type radical were found together with a high concentration of unreacted perferryl species. The reactivity of BHA, BHT and p-hydroxyanisole with free thiol groups is demonstrated by an increased reaction rate in the presence of the thiol group blocking substance NEM.

  13. Activation of C-H bonds by rare-earth metallocene-butyl complexes.

    PubMed

    Grindell, Richard; Day, Benjamin M; Guo, Fu-Sheng; Pugh, Thomas; Layfield, Richard A

    2017-09-05

    The stable metallocene-butyl complexes [(Cp Me ) 2 M( n Bu)] 2 (M = Y, Dy) were synthesized and their reactivity towards to ferrocene and bulky N-heterocyclic carbenes investigated. Selective mono-deprotonation of ferrocene and a benzylic methyl group of IMes were observed, whereas a control reaction of (Cp Me ) 3 M with IMes resulted in a normal-to-abnormal NHC rearrangement.

  14. Scattering of glue by glue on the light-cone worldsheet. II. Helicity conserving amplitudes

    NASA Astrophysics Data System (ADS)

    Chakrabarti, D.; Qiu, J.; Thorn, C. B.

    2006-08-01

    This is the second of a pair of articles on scattering of glue by glue, in which we give the light-cone gauge calculation of the one-loop on-shell helicity conserving scattering amplitudes for gluon-gluon scattering (neglecting quark loops). The 1/p+ factors in the gluon propagator are regulated by replacing p+ integrals with discretized sums omitting the p+=0 terms in each sum. We also employ a novel ultraviolet regulator that is convenient for the light-cone worldsheet description of planar Feynman diagrams. The helicity conserving scattering amplitudes are divergent in the infrared. The infrared divergences in the elastic one-loop amplitude are shown to cancel, in their contribution to cross sections, against ones in the cross section for unseen bremsstrahlung gluons. We include here the explicit calculation of the latter, because it assumes an unfamiliar form due to the peculiar way discretization of p+ regulates infrared divergences. In resolving the infrared divergences we employ a covariant definition of jets, which allows a transparent demonstration of the Lorentz invariance of our final results. Because we use an explicit cutoff of the ultraviolet divergences in exactly four spacetime dimensions, we must introduce explicit counterterms to achieve this final covariant result. These counterterms are polynomials in the external momenta of the precise order dictated by power counting. We discuss the modifications they entail for the light-cone worldsheet action that reproduces the bare planar diagrams of the gluonic sector of QCD. The simplest way to do this is to interpret the QCD string as moving in six spacetime dimensions.

  15. Molecular recognition at methyl methacrylate/n-butyl acrylate (MMA/nBA) monomer unit boundaries of phospholipids at p-MMA/nBA copolymer surfaces.

    PubMed

    Yu, Min; Urban, Marek W; Sheng, Yinghong; Leszczynski, Jerzy

    2008-09-16

    Lipid structural features and their interactions with proteins provide a useful vehicle for further advances in membrane proteins research. To mimic one of potential lipid-protein interactions we synthesized poly(methyl methacrylate/ n-butyl acrylate) (p-MMA/nBA) colloidal particles that were stabilized by phospholipid (PLs). Upon the particle coalescence, PL stratification resulted in the formation of surface localized ionic clusters (SLICs). These entities are capable of recognizing MMA/nBA monomer interfaces along the p-MMA/nBA copolymer backbone and form crystalline SLICs at the monomer interface. By utilizing attenuated total reflectance Fourier transform infrared (ATR FT-IR) spectroscopy and selected area electron diffraction (SAD) combined with ab initio calculations, studies were conducted that identified the origin of SLICs as well as their structural features formed on the surface of p-MMA/nBA copolymer films stabilized by 1,2-dilauroyl-sn-glycero-3-phosphocholine (DLPC) PL. Specific entities responsible for SLIC formation are selective noncovalent bonds of anionic phosphate and cationic quaternary ammonium segments of DLPC that interact with two neighboring carbonyl groups of nBA and MMA monomers of the p-MMA/nBA polymer backbone. To the best of our knowledge this is the first example of molecular recognition facilitated by coalescence of copolymer colloidal particles and the ability of PLs to form SLICs at the boundaries of the neighboring MMA and nBA monomer units of the p-MMA/nBA chain. The dominating noncovalent bonds responsible for the molecular recognition is a combination of H-bonding and electrostatic interactions.

  16. Cross-linking by protein oxidation in the rapidly setting gel-based glues of slugs.

    PubMed

    Bradshaw, Andrew; Salt, Michael; Bell, Ashley; Zeitler, Matt; Litra, Noelle; Smith, Andrew M

    2011-05-15

    The terrestrial slug Arion subfuscus secretes a glue that is a dilute gel with remarkable adhesive and cohesive strength. The function of this glue depends on metals, raising the possibility that metal-catalyzed oxidation plays a role. The extent and time course of protein oxidation was measured by immunoblotting to detect the resulting carbonyl groups. Several proteins, particularly one with a relative molecular mass (M(r)) of 165 x 10³, were heavily oxidized. Of the proteins known to distinguish the glue from non-adhesive mucus, only specific size variants were oxidized. The oxidation appears to occur within the first few seconds of secretion. Although carbonyls were detected by 2,4-dinitrophenylhydrazine (DNPH) in denatured proteins, they were not easily detected in the native state. The presence of reversible cross-links derived from carbonyls was tested for by treatment with sodium borohydride, which would reduce uncross-linked carbonyls to alcohols, but stabilize imine bonds formed by carbonyls and thus lead to less soluble complexes. Consistent with imine bond formation, sodium borohydride led to a 20-35% decrease in the amount of soluble protein with a M(r) of 40-165 (x 10³) without changing the carbonyl content per protein. In contrast, the nucleophile hydroxylamine, which would competitively disrupt imine bonds, increased protein solubility in the glue. Finally, the primary amine groups on a protein with a M(r) of 15 x 10³ were not accessible to acid anhydrides. The results suggest that cross-links between aldehydes and primary amines contribute to the cohesive strength of the glue.

  17. Cross-linking by protein oxidation in the rapidly setting gel-based glues of slugs

    PubMed Central

    Bradshaw, Andrew; Salt, Michael; Bell, Ashley; Zeitler, Matt; Litra, Noelle; Smith, Andrew M.

    2011-01-01

    SUMMARY The terrestrial slug Arion subfuscus secretes a glue that is a dilute gel with remarkable adhesive and cohesive strength. The function of this glue depends on metals, raising the possibility that metal-catalyzed oxidation plays a role. The extent and time course of protein oxidation was measured by immunoblotting to detect the resulting carbonyl groups. Several proteins, particularly one with a relative molecular mass (Mr) of 165×103, were heavily oxidized. Of the proteins known to distinguish the glue from non-adhesive mucus, only specific size variants were oxidized. The oxidation appears to occur within the first few seconds of secretion. Although carbonyls were detected by 2,4-dinitrophenylhydrazine (DNPH) in denatured proteins, they were not easily detected in the native state. The presence of reversible cross-links derived from carbonyls was tested for by treatment with sodium borohydride, which would reduce uncross-linked carbonyls to alcohols, but stabilize imine bonds formed by carbonyls and thus lead to less soluble complexes. Consistent with imine bond formation, sodium borohydride led to a 20–35% decrease in the amount of soluble protein with a Mr of 40–165 (×103) without changing the carbonyl content per protein. In contrast, the nucleophile hydroxylamine, which would competitively disrupt imine bonds, increased protein solubility in the glue. Finally, the primary amine groups on a protein with a Mr of 15×103 were not accessible to acid anhydrides. The results suggest that cross-links between aldehydes and primary amines contribute to the cohesive strength of the glue. PMID:21525316

  18. Kinetics of proton transfer from tetra(4-nitro-5- tert-butyl)phthalocyanine to nitrogen-containing bases in benzene

    NASA Astrophysics Data System (ADS)

    Petrov, O. A.; Kuzmina, E. L.; Maizlish, V. E.; Rodionov, A. V.

    2014-01-01

    The acid-basic interaction between tetra(4-nitro-5- tert-butyl)phthalocyanine and pyridine, 2-methylpyridine, morpholine, piperidine, n-butylamine, diethylamine, and triethylamine in benzene is studied. It is found that the intermolecular transfer of protons of NH groups from tetra(4-nitro-5- tert-butyl)phthalocyanine to morpholine and diethylamine is characterized by unusually low values of the reaction constant rates. The effect of the structure of tetra(4-nitro-5- tert-butyl)phthalocyanine and tetra(3-nitro-5- tert-butyl)phthalocyanine, and of the nature of the base on the kinetic parameters of acid-base interaction is demonstrated. A structure is proposed for complexes with the transfer of displaced phthalocyanines' protons. It is found that they undergo decomposition over time.

  19. Porcine wound healing in full-thickness skin defects using Integra™ with and without fibrin glue with keratinocytes

    PubMed Central

    Melendez, Mark M; Martinez, Rodrigo R; Dagum, Alexander B; McClain, Steve A; Simon, Marcia; Sobanko, Joseph; Zimmerman, Thomas; Wetterau, Meredith; Muller, Douglas; Xu, Xiaoti; Singer, Adam J; Arora, Balvantray

    2008-01-01

    BACKGROUND: An artificial dermal matrix such as Integra (Integra Life Sciences Corporation, USA) provides a wound bed template for vascular and fibrocyte ingrowth as well as collagen remodelling. Dermal repair leads to epidermal and basement membrane regeneration. Burn wounds in particular have been shown to benefit from Integra by enhanced wound healing. OBJECTIVE: To evaluate the effect of fibrin glue to modify the integration of Integra in large excised cutaneous wounds. It was hypothesized that applying fibrin glue on a wound bed would reduce the time needed for matrix vascularization and incorporation of Integra and take of the cultured keratinocytes. METHODS: Four separate full-thickness wounds were created on the dorsum of two swine. Wound beds were randomly assigned to either application of fibrin glue or no application of fibrin glue before application of Integra. Full-thickness biopsies were performed at days 7, 14, 21, 29 and 35. On day 21, keratinocytes were applied either as sheets or aerosolized fibrin glue suspension. RESULTS: Histological analysis revealed a wave of inflammatory cells and early granulation tissue ingrowth into the Integra from the fascia below on day 7. Only this initial phase was augmented by application of fibrin glue to the wound bed. By day 14, most and by day 21, all of the Integra thickness was incorporated. Accelerated dermal repair proceeded from the base with new collagen deposition in Integra spaces. There was no evidence of keratinocyte engraftment, although re-epithelialization occurred at wound edges extending onto the incorporated Integra. CONCLUSIONS: It appears there is an acceleration of early phase (day 7 to day 21) dermal incorporation with fibrin glue application to the wound bed, perhaps secondary to increased cellular migration. Day 21 appears to be too early to apply cultured keratinocytes either as sheets or aerosolized suspension. PMID:19721792

  20. GLUE 2 deployment: Ensuring quality in the EGI/WLCG information system

    NASA Astrophysics Data System (ADS)

    Burke, Stephen; Alandes Pradillo, Maria; Field, Laurence; Keeble, Oliver

    2014-06-01

    The GLUE 2 information model is now fully supported in the production EGI/WLCG information system. However, to make it usable and allow clients to rely on the published information it is important that the meaning is clearly defined, and that information providers and site configurations are validated to ensure as far as possible that what they publish is correct. In this paper we describe the definition of a detailed schema usage profile, the implementation of a software tool to validate published information according to the profile and the use of the tool in the production Grid, and also summarise the overall state of GLUE 2 deployment.

  1. PRODUCTS OF THE GAS-PHASE REACTIONS OF THE OH RADICAL WITH N-BUTYL METHYL ETHER AND 2-ISOPROPOXYETHANOL: REACTIONS OF ROC(O)< RADICALS. (R825252)

    EPA Science Inventory

    The products of the gas-phase reactions of the OH radical with n-butyl methyl ether and 2-isopropoxyethanol in the presence of NO have been investigated at 298 ? 2 K and 740 Torr total pressure of air by gas chromatography and in situ atmospheric pressure ionization...

  2. [Experimental study on repair of the defect of the pars interarticularis in rat with bone morphogenetic protein and fibrin glue].

    PubMed

    Nakamura, T

    1992-07-01

    The possibility of repairing the defect of the pars interarticularis (pars defect) with Bone Morphogenetic Protein (BMP) and fibrin glue was studied. The pars defect established in the 5th lumbar vertebra of Wistar rat was treated with surgical implantation of a composite consisting of BMP, fibrin glue and autologous cancellous bone. At 3, 6, 9 and 12 weeks after implantation, the osteoinductive activity in the pars defect was observed histologically and compared with that of other composite implants such as BMP with fibrin glue, autologous cancellous bone alone and autologous cancellous bone with fibrin glue. Although perfect bone fusion was not obtained with any of the composites employed, a significant increase in bone formation was seen in a composite of BMP, fibrin glue and autologous cancellous bone (p less than 0.01) as compared with that seen in the others. Consequently, implantation of BMP and fibrin glue combined with some biomaterials which support osteo-induction of BMP and stabilize the pars defect might be successfully applied to repair the pars defect.

  3. Calibration of cathode strip gains in multiwire drift chambers of the GlueX experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berdnikov, V. V.; Somov, S. V.; Pentchev, L.

    A technique for calibrating cathode strip gains in multiwire drift chambers of the GlueX experiment is described. The accuracy of the technique is estimated based on Monte Carlo generated data with known gain coefficients in the strip signal channels. One of the four detector sections has been calibrated using cosmic rays. Results of drift chamber calibration on the accelerator beam upon inclusion in the GlueX experimental setup are presented.

  4. (N-Benzyl-N-ethyl­dithio­carbamato)di-tert-butyl­chloridotin(IV)

    PubMed Central

    Abdul Muthalib, Amirah Faizah; Baba, Ibrahim; Mohamed Tahir, Mohamed Ibrahim; Tiekink, Edward R. T.

    2011-01-01

    The SnIV atom in the title diorganotin dithio­carbamate, [Sn(C4H9)2Cl(C10H12NS2)], is penta­coordinated by an asymmetrically coordinating dithio­carbamate ligand, a Cl and two C atoms of the Sn-bound tert-butyl groups. The resulting C2ClS2 donor set defines a coordination geometry inter­mediate between square pyramidal and trigonal bipyramidal with a slight tendency towards the former. In the crystal structure, C—H⋯π contacts link centrosymmetrically related mol­ecules into dimeric aggregates. PMID:21522295

  5. Acute nonlymphocytic leukemia in a glue sniffer.

    PubMed

    Caligiuri, M A; Early, A P; Marinello, M J; Preisler, H D

    1985-09-01

    A 17-year-old white male with a past history of chronic inhalational abuse of plastic glue was referred to our institution for sore throat, cervical adenopathy, and an abnormal peripheral blood smear. A diagnosis of acute myelomonocytic leukemia was made and abnormalities in cytogenetic studies were demonstrated. Specific inquiry regarding this form of drug exposure should be pursued when searching for possible etiologies of malignant disease.

  6. Glue septal ablation: A promising alternative to alcohol septal ablation

    PubMed Central

    Aytemir, Kudret; Oto, Ali

    2016-01-01

    Hypertrophic cardiomyopathy (HCM) is defined as myocardial hypertrophy in the absence of another cardiac or systemic disease capable of producing the magnitude of present hypertrophy. In about 70% of patients with HCM, there is left ventricular outflow tract (LVOT) obstruction (LVOTO) and this is known as obstructive type of hypertrophic cardiomyopathy (HOCM). Cases refractory to medical treatment have had two options either surgical septal myectomy or alcohol septal ablation (ASA) to alleviate LVOT gradient. ASA may cause some life-threatening complications including conduction disturbances and complete heart block, hemodynamic compromise, ventricular arrhythmias, distant and massive myocardial necrosis. Glue septal ablation (GSA) is a promising technique for the treatment of HOCM. Glue seems to be superior to alcohol due to some intrinsic advantageous properties of glue such as immediate polymerization which prevents the leak into the left anterior descending coronary artery and it is particularly useful in patients with collaterals to the right coronary artery in whom alcohol ablation is contraindicated. In our experience, GSA is effective and also a safe technique without significant complications. GSA decreases LVOT gradient immediately after the procedure and this reduction persists during 12 months of follow-up. It improves New York Heart Association functional capacity and decrease interventricular septal wall thickness. Further studies are needed in order to assess the long-term efficacy and safety of this technique. PMID:27011786

  7. Effect of Fibrin Glue on the Biomechanical Properties of Human Descemet's Membrane

    PubMed Central

    Chaurasia, Shyam S.; Champakalakshmi, Ravi; Li, Ang; Poh, Rebekah; Tan, Xiao Wei; Lakshminarayanan, Rajamani; Lim, Chwee T.; Tan, Donald T.; Mehta, Jodhbir S.

    2012-01-01

    Background Corneal transplantation has rapidly evolved from full-thickness penetrating keratoplasty (PK) to selective tissue corneal transplantation, where only the diseased portions of the patient's corneal tissue are replaced with healthy donor tissue. Descemet's membrane endothelial keratoplasty (DMEK) performed in patients with corneal endothelial dysfunction is one such example where only a single layer of endothelial cells with its basement membrane (10–15 µm in thickness), Descemet's membrane (DM) is replaced. It is challenging to replace this membrane due to its intrinsic property to roll in an aqueous environment. The main objective of this study was to determine the effects of fibrin glue (FG) on the biomechanical properties of DM using atomic force microscopy (AFM) and relates these properties to membrane folding propensity. Methodology/Principal Findings Fibrin glue was sprayed using the EasySpray applicator system, and the biomechanical properties of human DM were determined by AFM. We studied the changes in the “rolling up” tendency of DM by examining the changes in the elasticity and flexural rigidity after the application of FG. Surface topography was assessed using scanning electron microscopy (SEM) and AFM imaging. Treatment with FG not only stabilized and stiffened DM but also led to a significant increase in hysteresis of the glue-treated membrane. In addition, flexural or bending rigidity values also increased in FG-treated membranes. Conclusions/Significance Our results suggest that fibrin glue provides rigidity to the DM/endothelial cell complex that may aid in subsequent manipulation by maintaining tissue integrity. PMID:22662156

  8. Restoration of small bone defects at craniotomy using autologous bone dust and fibrin glue.

    PubMed

    Matsumoto, K; Kohmura, E; Kato, A; Hayakawa, T

    1998-10-01

    Bone gaps or burr holes often result in small but undesirable scalp or skin depressions after craniotomy. Whereas a number of reports have discussed cranioplasties to avoid large bone defects, little has been written about the problem of small bone defects which, despite their minor size, could result in bothersome cosmetic problems. This study was designed to assess a simple method to repair burr hole defects and bridge bone gaps with autologous bone dust and fibrin glue. Bone dust was collected when burr holes were created or craniectomy was performed. After replacement of the bone flap, the burr holes or bone gap were filled with a mixture of bone dust and fibrin glue. The mixture of bone dust and fibrin glue was easily shaped to fit bone defects, resulting in favorable cosmetic outcomes 1 to 5 years after operation.

  9. Portal Vein Embolization Before Liver Resection: A Systematic Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lienden, K. P. van, E-mail: k.p.vanlienden@amc.uva.nl; Esschert, J. W. van den; Graaf, W. de

    2013-02-15

    This is a review of literature on the indications, technique, and outcome of portal vein embolization (PVE). A systematic literature search on outcome of PVE from 1990 to 2011 was performed in Medline, Cochrane, and Embase databases. Forty-four articles were selected, including 1,791 patients with a mean age of 61 {+-} 4.1 years. Overall technical success rate was 99.3 %. The mean hypertrophy rate of the FRL after PVE was 37.9 {+-} 0.1 %. In 70 patients (3.9 %), surgery was not performed because of failure of PVE (clinical success rate 96.1 %). In 51 patients (2.8 %), the hypertrophymore » response was insufficient to perform liver resection. In the other 17 cases, 12 did not technically succeed (0.7 %) and 7 caused a complication leading to unresectability (0.4 %). In 6.1 %, resection was cancelled because of local tumor progression after PVE. Major complications were seen in 2.5 %, and the mortality rate was 0.1 %. A head-to-head comparison shows a negative effect of liver cirrhosis on hypertrophy response. The use of n-butyl cyanoacrylate seems to have a greater effect on hypertrophy, but the difference with other embolization materials did not reach statistical significance. No difference in regeneration is seen in patients with cholestasis or chemotherapy. Preoperative PVE has a high technical and clinical success rate. Liver cirrhosis has a negative effect on regeneration, but cholestasis and chemotherapy do not seem to have an influence on the hypertrophy response. The use of n-butyl cyanoacrylate may result in a greater hypertrophy response compared with other embolization materials used.« less

  10. Preoperative Embolization of Skull Base Meningiomas: Outcomes in the Onyx Era.

    PubMed

    Przybylowski, Colin J; Baranoski, Jacob F; See, Alfred P; Flores, Bruno C; Almefty, Rami O; Ding, Dale; Chapple, Kristina M; Sanai, Nader; Ducruet, Andrew F; Albuquerque, Felipe C

    2018-05-09

    Preoperative embolization may facilitate skull base meningioma resection, but its safety and efficacy in the Onyx era have not been investigated. In this retrospective cohort study, we evaluated the outcomes of preoperative embolization of skull base meningiomas using Onyx as the primary embolysate. We queried an endovascular database for patients with skull base meningiomas who underwent preoperative embolization at our institution in 2007-2017. Patient, tumor, procedure, and outcome data were analyzed. Twenty-eight patients (28 meningiomas) underwent successful preoperative meningioma embolization. The mean patient age ± SD was 56 ± 13 years, and 18 patients (64%) were women. The mean tumor size was 49 cm 3 . There were 1, 2, or 3 arterial pedicles embolized in 21 cases (75%), 6 cases (21%), and 1 case (4%), respectively. The embolized pedicles included branches of the middle meningeal artery in 19 cases (68%), the internal maxillary artery in 8 cases (29%), the ascending pharyngeal artery in 2 cases (7%), and the posterior auricular, ophthalmic, occipital, and anterior cerebral arteries in 1 case each (4%). The embolysates used were Onyx alone in 20 cases (71%), n-butyl cyanoacrylate alone in 3 cases (11%), coils/particles and Onyx/n-butyl cyanoacrylate in 2 cases each (7%), and Onyx and coils in 1 case (4%). The median degree of tumor devascularization was 60%. Significant neurologic morbidity occurred in 1 patient (4%) who developed symptomatic peritumoral edema after Onyx embolization. For appropriately selected skull base meningiomas supplied by dura mater-based arterial pedicles without distal cranial nerve supply, preoperative embolization with current embolysate technology affords substantial tumor devascularization with a low complication rate. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Flash Pyrolysis of t-Butyl Hydroperoxide and Di-t-butyl Peroxide: Evidence of Roaming in the Decomposition of Organic Hydroperoxides.

    PubMed

    Jones, Paul J; Riser, Blake; Zhang, Jingsong

    2017-10-19

    Thermal decomposition of t-butyl hydroperoxide and di-t-butyl peroxide was investigated using flash pyrolysis (in a short reaction time of <100 μs) and vacuum-ultraviolet (λ = 118.2 nm) single-photon ionization time-of-flight mass spectrometry (VUV-SPI-TOFMS) at temperatures up to 1120 K and quantum computational methods. Acetone and methyl radical were detected as the predominant products in the initial decomposition of di-t-butyl peroxide via O-O bond fission. In the initial dissociation of t-butyl hydroperoxide, acetone, methyl radical, isobutylene, and isobutylene oxide products were identified. The novel detection of the unimolecular formation of isobutylene oxide, as supported by the computational study, was found to proceed via a roaming hydroxyl radical facilitated by a hydrogen-bonded intermediate. This new pathway could provide a new class of reactions to consider in the modeling of the low temperature oxidation of alkanes.

  12. t-Butyl-Oxycarbonylated Diamines as Building Blocks for Isocyanate-Free Polyurethane/Urea Dispersions and Coatings.

    PubMed

    Ma, Shuang; Zhang, Huiyi; Sablong, Rafaël J; Koning, Cor E; van Benthem, Rolf A T M

    2018-05-01

    t-Butyl-oxycarbonylated diamines ("di-Boc-carbamates") are investigated as dicarbamate monomers for diamine/dicarbamate polymerizations. Polyureas (PUs) and polyurethanes (PURs) with high molecular weights are prepared from stoichiometric polymerizations of diamines or diols with N-N'-di-t-butyl-oxycarbonyl isophorone diamine (DiBoc-IPDC) using KOt-Bu as a catalyst, while gelation is observed when an excess of DiBoc-IPDC is used with respect to the diamines or diols. Stable dispersions are obtained from PUs and PURs with 3,3'-diamino-N-methyldipropylamine (DMDPA) as internal dispersing agent. The corresponding PU-based coatings exhibit superior mechanical properties and solvent resistances compared to the polyurethane urea coatings synthesized from diols, DiBoc-IPDC, and DMDPA. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Toxic effects of butyl elastomers on aerobic methane oxidation

    NASA Astrophysics Data System (ADS)

    Niemann, Helge; Steinle, Lea I.; Blees, Jan H.; Krause, Stefan; Bussmann, Ingeborg; Lehmann, Moritz F.; Treude, Tina

    2013-04-01

    Large quantities of the potent greenhouse gas methane are liberated into the water column of marine and lacustrine environments where it may be consumed by aerobic methane oxidising bacteria before reaching the atmosphere.The reliable quantification of aerobic methane oxidation (MOx) rates is consequently of paramount importance for estimating methane budgets and to understand the controls on water column methane cycling. A widely used set of methods for measuring MOx rates is based on the incubation of water samples during which the consumption of methane is monitored, for instance with radio-tracer assays. Typically, incubation vessels are sealed with butyl rubber stoppers because these elastomers are essentially impermeable for gases at the relevant time scales. We tested the effect of different stopper materials (unmodified- and halogenated butyl rubber) on MOx activity in environmental samples and in cultures of methane oxidising bacteria. MOx rates in samples sealed with unmodified butyl rubber were > 75% lower compared to parallel incubations with halogenated butyl rubber seals, suggesting inhibiting/toxic effects associated with the use of unmodified butyl elastomers. To further explore the cause of these effects, we analysed aqueous extracts of the different stoppers. Halogenated butyl rubber stoppers appeared to bleed off comparably little amounts of organics. In stark contrast, extracts of unmodified butyl rubber were contaminated with various organic compounds including potential bactericides such as benzyltoluenes, phenylalkanes and benzuothiazoles. We also found tetramethylthiourea, a scavenger of active oxygen species, which may inhibit the MOx pathway.

  14. A comparative study of tissue glue and vicryl suture for conjunctival and scleral closure in conventional 20-gauge vitrectomy.

    PubMed

    Batman, C; Ozdamar, Y; Mutevelli, S; Sonmez, K; Zilelioglu, G; Karakaya, J

    2009-06-01

    To describe the use of tissue glue to close scleral and conjunctival wounds, and to compare the clinical outcomes using tissue glue and vicryl suture for closing these areas in conventional 20-gauge (G) vitrectomy. Thirty eyes of 30 patients were included in this study. The indications for vitreoretinal surgery were diabetic vitreous haemorrhage with severe vitreoretinal traction in 10 eyes, retinal detachment and proliferative vitreoretinopathy in 14 eyes, and vitreous opacity in 6 eyes. Tissue glue (Tisseel, Baxter AG Industries, Vienna, Austria) was used to attach scleral and conjunctival wounds in 15 eyes and vicryl sutures in 15 eyes. The patients were allotted into two subgroups as tissue glue group (TG) and vicryl suture group (VG). The sclerotomy sites were evaluated with ultrasound biomicroscopy (UBM) postoperatively in TG. Follow-up period was 2 months. The groups were statistically compared for ocular signs and symptoms by Mann-Whitney U-test. No scleral wound leakage and conjunctival reattachment were observed at the end of the surgical procedure and during the follow-up period. No adverse effects were seen in TG. Abnormal fibrous ingrowth was not detected at the sclerotomy sites by means of UBM in TG. Patient comfort was significantly higher in TG than VG (P<0.05). Tissue glue has no adverse effects on ocular tissue and can be used as a substitute for suture materials, and the use of tissue glue decreases patient symptoms during the postoperative period after 20-G vitrectomy. Tissue glue can enable to perform sutureless surgery in the conventional 20-G vitrectomy.

  15. Comparison of Arterial Repair through the Suture, Suture with Fibrin or Cyanoacrylate Adhesive in Ex-Vivo Porcine Aortic Segment

    PubMed Central

    de Carvalho, Marcus Vinicius H.; Marchi, Evaldo; Lourenço, Edmir Américo

    2017-01-01

    Introduction Tissue adhesives can be used as adjacent to sutures to drop or avoid bleeding in cardiovascular operations. Objective To verify the efficiency of fibrin and cyanoacrylate adhesive to seal arterial sutures and if the adhesives penetrate through suture line to the inner of arteries. Methods 20 abdominal aorta segments of pigs were divided into two groups according to the adhesive which would be used as adjacent to the suture. In every arterial segment an arteriotomy was done, followed by a conventional artery closure. Afterwards a colloidal fluid was injected inside the arterial segment with a simultaneous intravascular pressure monitoring up to a fluid leakage through the suture. This procedure was repeated after application of one of the adhesives on the suture in order to check if the bursting pressure increases. The inner aorta segments also were analyzed in order to check if there was intraluminal adhesive penetration. Results In Suture 1 group, the mean arterial pressure sustained by the arterial suture reached 86±5.35 mmHg and after the fibrin adhesive application reached 104±11.96 (P<0.002). In the Suture 2 group, the mean arterial pressure sustained by the suture reached 83±2.67 mmHg and after the cyanoacrylate adhesive application reached 152±14.58 mmHg (P<0.002). Intraluminal adhesive penetration has not been noticed. Conclusion There was a significant rise in the bursting pressure when tissue adhesives were used as adjacent to arterial suture, and this rise was higher if the cyanoacrylate adhesive was used. In addition, the adhesives do not penetrate through the suture line into the arteries. PMID:29267611

  16. Deep Circumflex Iliac Artery-Related Hemoperitoneum Formation After Surgical Drain Placement: Successful Transcatheter Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Sang Woo; Chang, Seong-Hwan, E-mail: csh@kuh.ac.kr; Yun, Ik Jin

    A 53-year-old woman with liver cirrhosis and hepatocellular carcinoma underwent living donor liver transplantation. After transplantation, her hemoglobin and hematocrit levels decreased to 6.3 g/dl and 18.5%, respectively, during the course of 3 days. A contrast-enhanced abdominal computed axial tomography (CAT) scan showed a hemoperitoneum in the right perihepatic space with no evidence of abdominal wall hematoma or pseudoaneurysm formation. An angiogram of the deep circumflex iliac artery (DCIA) showed extravasation of contrast media along the surgical drain, which had been inserted during the transplantation procedure. Transcatheter embolization of the branches of the DCIA was successfully performed using N-butyl cyanoacrylate.

  17. Endoscopic Ultrasound (EUS) for Esophageal and Gastric Varices: How Can it Improve the Outcomes and Reduce Complications of Glue Injection

    PubMed Central

    Bhatia, Vikram

    2012-01-01

    A large part of portal venous system and the paragastric and para-esophageal collateral circulation is within the reach of endoscopic ultrasound (EUS). The EUS is more sensitive than gastroscopy for the detection of gastric varices (GV), and can accurately distinguish GV from thickened gastric folds. Gastric varices are depicted by serpiginous, anechoic, Doppler-positive mural channels, with larger collateral channels visible outside the gastric wall. The EUS has also been used to monitor the completeness of GV obturation after glue injection. There are limited data that this strategy may be clinically beneficial to prevent GV re-bleed. The EUS has been used to deliver glue injections under real-time monitoring into the vascular channels, with or without steel coils as scaffolding for the glue. The potential advantages of this technique include a straight scope position, lack of hindrance from pooled blood in gastric fundus, smaller glue volume requirements, and precise intra-vascular placement of glue with avoidance of intramural injections, and reduced embolic complications. PMID:25755407

  18. A new postoperative otoplasty dressing technique using cyanoacrylate tissue adhesives.

    PubMed

    Vetter, Miriam; Foehn, Matthias; Wedler, Volker

    2010-04-01

    There are many techniques for cosmetic surgery of the ears and also many different procedures for postoperative treatment. The postoperative dressing is described as important for a successful outcome. We present our method of postoperative dressing in the form of liquid bonding. Cyanoacrylate tissue adhesives as liquid bonding agents are used for fixation of the pinna at the mastoid area. After 10-14 days the bonding can be easily removed. No huge dressings, tapes, or plasters are necessary. The patients are satisfied with the light dressing; they do not feel ashamed to appear in public. We have found this dressing technique to be simple and economical, especially because of the use of the bonding for skin closure before. It can be used after otoplasty with an anterior or a posterior approach.

  19. The High-Energy Photoproduction of Light-Quark Pseudoscalar and Scalar Meson at GlueX

    NASA Astrophysics Data System (ADS)

    Zhang, Zhenyu

    The high-energy photoproduction of light-quark pseudoscalar and scalar mesons is an effective tool for understanding the properties of strong interaction in the nonperturbative regime. It has been investigated theoretically using Regge-cut phenomenology with massive quasi-particle exchange in the high-energy regime, and the linearly polarized photon beam asymmetry Σ can provide insight into the dominant production mechanism. In the low-energy region, it can provide constraints on ”background” to baryon resonance extraction. With an almost 50-year history, intensive experiments on meson photoproduction are growing vigorously at several international laboratories, such as JLab, ELSA, and MAMI. Recently the beam asymmetry Σ in high-energy π0/η photoproduction has been measured at GlueX, which is the first measurement both from the GlueX experiment and the 12 GeV upgraded JLab. The highest precision measurement of the π0 asymmetry and the first measurement of η beam asymmetry at a beam energy above 3 GeV are presented. A broad meson photoproduction project, including scalar meson a0(980)/f0(980), is under way at GlueX. In the proceedings, we report the beam asymmetry results for π0/η photoproduction at GlueX, as well as preliminary results for scalar meson photoproduction in the π0π0 and π0η channels.

  20. HIGH LEVELS OF MONOAROMATIC COMPOUNDS LIMIT THE USE OF SOLID-PHASE MICROEXTRACTION OF METHYL TERTIARY BUTYL ETHER AND TERTIARY BUTYL ALCOHOL

    EPA Science Inventory

    Recently, two papers reported the use of solid-phase microextraction (SPME) with polydimethylsiloxane(PDMS)/Carboxen fibers to determine trace levels of methyl tertiary butyl ether (MTBE) and tertiary butyl alcohol (tBA) in water. Attempts were made to apply this technique to th...

  1. A series of (E)-5-(arylideneamino)-1-tert-butyl-1H-pyrrole-3-carbonitriles and their reduction products to secondary amines: syntheses and X-ray structural studies.

    PubMed

    Macías, Mario A; Castillo, Juan Carlos; Portilla, Jaime

    2018-01-01

    An efficent access to a series of N-(pyrrol-2-yl)amines, namely (E)-1-tert-butyl-5-[(4-chlorobenzylidene)amino]-1H-pyrrole-3-carbonitrile, C 16 H 16 ClN 3 , (7a), (E)-1-tert-butyl-5-[(2,4-dichlorobenzylidene)amino]-1H-pyrrole-3-carbonitrile, C 16 H 15 Cl 2 N 3 , (7b), (E)-1-tert-butyl-5-[(pyridin-4-ylmethylene)amino]-1H-pyrrole-3-carbonitrile, C 15 H 16 N 4 , (7c), 1-tert-butyl-5-[(4-chlorobenzyl)amino]-1H-pyrrole-3-carbonitrile, C 16 H 18 ClN 3 , (8a), and 1-tert-butyl-5-[(2,4-dichlorobenzyl)amino]-1H-pyrrole-3-carbonitrile, C 16 H 17 Cl 2 N 3 , (8b), by a two-step synthesis sequence (solvent-free condensation and reduction) starting from 5-amino-1-tert-butyl-1H-pyrrole-3-carbonitrile is described. The syntheses proceed via isolated N-(pyrrol-2-yl)imines, which are also key synthetic intermediates of other valuable compounds. The crystal structures of the reduced compounds showed a reduction in the symmetry compared with the corresponding precursors, viz. Pbcm to P-1 from compound (7a) to (8a) and P2 1 /c to P-1 from compound (7b) to (8b), probably due to a severe change in the molecular conformations, resulting in the loss of planarity observed in the nonreduced compounds. In all of the crystals, the supramolecular assembly is controlled mainly by strong (N,C)-H...N hydrogen bonds. However, in the case of (7a)-(7c), C-H...Cl interactions are strong enough to help in the three-dimensional architecture, as observed in Hirshfeld surface maps.

  2. Accelerated aging of EPDM and butyl elastomers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, M.H.

    1996-06-01

    This study was composed of three parts: a post cure study to optimize final properties of an ethylene-propylene-diene (EPDM) formulation, an accelerated aging study to compare the stress relaxation behavior of a butyl and an EPDM elastomer under compression, and a cursory evaluation of a new 70 Shore A EPDM. The optimum postcure for the EPDM was found to be 2 to 4 hours at 182{degrees}C in a vacuum. The EPDM was also shown to have superior aging characteristics compared to the butyl and is recommended for use instead of the butyl material. The physical properties for new 70 Shoremore » A EPDM are satisfactory, and the stress relaxation behavior was only slightly inferior to the other EPDM.« less

  3. Successful Endoscopic Management of Non-Healing Perforated Duodenal Ulcer with Polyglycolic Acid Sheet and Fibrin Glue.

    PubMed

    Mishiro, Tsuyoshi; Shibagaki, Kotaro; Matsuda, Kayo; Fukuyama, Chika; Okada, Mayumi; Mikami, Hironobu; Izumi, Daisuke; Yamashita, Noritsugu; Okimoto, Eiko; Fukuda, Naoki; Aimi, Masahito; Fukuba, Nobuhiko; Oshima, Naoki; Takanashi, Toshihiro; Matsubara, Takeshi; Ishimura, Norihisa; Ishihara, Shunji; Kinoshita, Yoshikazu

    2016-08-01

    In recent years, treatment techniques in which polyglycolic acid sheets are applied to various situations with fibrin glue have exhibited great clinical potential, and previous studies have reported safety and efficacy. We describe closure of a non-healing perforated duodenal ulcer with the use of a polyglycolic acid sheet and fibrin glue in an elderly patient who was not a candidate for surgery.

  4. Study on the Optimal Groove Shape and Glue Material for Fiber Bragg Grating Measuring Bolts.

    PubMed

    Zhao, Yiming; Zhang, Nong; Si, Guangyao; Li, Xuehua

    2018-06-02

    Fiber Bragg grating (FBG) measuring bolts, as a useful tool to evaluate the behaviors of steel bolts in underground engineering, can be manufactured by gluing the FBG sensors inside the grooves, which are usually symmetrical cuts along the steel bolt rod. The selection of the cut shape and the glue types could perceivably affect the final supporting strength of the bolts. Unfortunately, the impact of cut shape and glue type on bolting strength is not yet clear. In this study, based on direct tension tests, full tensile load⁻displacement curves of rock bolts with different groove shapes were obtained and analyzed. The effects of groove shape on the bolt strength were discussed, and the stress redistribution in the cross-section of a rock bolt with different grooves was simulated using ANSYS. The results indicated that the trapezoidal groove is best for manufacturing the FBG bolt due to its low reduction of supporting strength. Four types of glues commonly used for the FBG sensors were assessed by conducting tensile tests on the mechanical testing and simulation system and the static and dynamic optical interrogators system. Using linear regression analysis, the relationship between the reflected wavelength of FBG sensors and tensile load was obtained. Practical recommendations for glue selection in engineering practice are also provided.

  5. Fibrin glue mixed with platelet-rich fibrin as a scaffold seeded with dental bud cells for tooth regeneration.

    PubMed

    Yang, Kai-Chiang; Wang, Chun-Hao; Chang, Hao-Hueng; Chan, Wing P; Chi, Chau-Hwa; Kuo, Tzong-Fu

    2012-11-01

    Odontogenesis is a complex process with a series of epithelial-mesenchymal interactions and odontogenic molecular cascades. In tissue engineering of teeth from stem cells, platelet-rich fibrin (PRF), which is rich in growth factors and cytokines, may improve regeneration. Accordingly, PRF was added into fibrin glue to enrich the microenvironment with growth factors. Unerupted second molar tooth buds were harvested from miniature swine and cultured in vitro for 3 weeks to obtain dental bud cells (DBCs). Whole blood was collected for the preparation of PRF and fibrin glue before surgery. DBCs were suspended in fibrin glue and then enclosed with PRF, and the DBC-fibrin glue-PRF composite was autografted back into the original alveolar sockets. Radiographic and histological examinations were used to identify the regenerated tooth structure 36 weeks after implantation. Immunohistochemical staining was used to detect proteins specific to tooth regeneration. One pig developed a complete tooth with crown, root, pulp, enamel, dentin, odontoblast, cementum, blood vessels, and periodontal ligaments in indiscriminate shape. Another animal had an unerupted tooth that expressed cytokeratin 14, dentin matrix protein-1, vascular endothelial growth factor, and osteopontin. This study demonstrated, using autogenic cell transplantation in a porcine model, that DBCs seeded into fibrin glue-PRF could regenerate a complete tooth. Copyright © 2011 John Wiley & Sons, Ltd.

  6. NMR analysis of t-butyl-catalyzed deuterium exchange at unactivated arene localities.

    PubMed

    Stack, Douglas E; Eastman, Rachel

    2016-10-01

    Regioselective labelling of arene rings via electrophilic exchange is often dictated by the electronic environment caused by substituents present on the aromatic system. Previously, we observed the presence of a t-butyl group, either covalently bond or added as an external reagent, could impart deuterium exchange to the unactivated, C1-position of estrone. Here, we provide nuclear magnetic resonance analysis of this exchange in a solvent system composed of 50:50 trifluoroacetic acid and D 2 O with either 2-t-butylestrone or estrone in the presence of t-butyl alcohol has shed insights into the mechanism of this t-butyl-catalyzed exchange. Fast exchange of the t-butyl group concurrent with the gradual reduction of the H1 proton signal in both systems suggest a mechanism involving ipso attack of the t-butyl position by deuterium. The reversible addition/elimination of the t-butyl group activates the H1 proton towards exchange by a mechanism of t-butyl incorporation, H1 activation and exchange, followed by eventual t-butyl elimination. Density functional calculations are consistent with the observation of fast t-butyl exchange concurrent with slower H1 exchange. The σ-complex resulting from ipso attack of deuterium at the t-butyl carbon was 6.6 kcal/mol lower in energy than that of the σ-complex resulting from deuterium attack at C1. A better understanding of the t-butyl-catalyzed exchange could help in the design of labelling recipes for other phenolic metabolites. Copyright © 2016 The Authors. Journal of Labelled Compounds and Radiopharmaceuticals published by John Wiley & Sons, Ltd.

  7. Inducing PLA/starch compatibility through butyl-etherification of waxy and high amylose starch.

    PubMed

    Wokadala, Obiro Cuthbert; Emmambux, Naushad Mohammad; Ray, Suprakas Sinha

    2014-11-04

    In this study, waxy and high amylose starches were modified through butyl-etherification to facilitate compatibility with polylactide (PLA). Fourier transform infrared spectroscopy, proton nuclear magnetic resonance spectroscopy and wettability tests showed that hydrophobic butyl-etherified waxy and high amylose starches were obtained with degree of substitution values of 2.0 and 2.1, respectively. Differential scanning calorimetry, tensile testing, and scanning electron microscopy (SEM) demonstrated improved PLA/starch compatibility for both waxy and high amylose starch after butyl-etherification. The PLA/butyl-etherified waxy and high amylose starch composite films had higher tensile strength and elongation at break compared to PLA/non-butyl-etherified composite films. The morphological study using SEM showed that PLA/butyl-etherified waxy starch composites had a more homogenous microstructure compared to PLA/butyl-etherified high amylose starch composites. Thermogravimetric analysis showed that PLA/starch composite thermal stability decreased with starch butyl-etherification for both waxy and high amylose starches. This study mainly demonstrates that PLA/starch compatibility can be improved through starch butyl-etherification. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Biodegradation of di-n-butyl phthalate (DBP) by a novel endophytic Bacillus megaterium strain YJB3.

    PubMed

    Feng, Nai-Xian; Yu, Jiao; Mo, Ce-Hui; Zhao, Hai-Ming; Li, Yan-Wen; Wu, Bing-Xiao; Cai, Quan-Ying; Li, Hui; Zhou, Dong-Mei; Wong, Ming-Hung

    2018-03-01

    Phthalic acid esters (PAEs) are a group of recalcitrant and hazardous organic compounds that pose a great threat to both ecosystem and human beings. A novel endophytic strain YJB3 that could utilize a wide range of PAEs as the sole carbon and energy sources for cell growth was isolated from Canna indica root tissue. It was identified as Bacillus megaterium based on morphological characteristics and 16S rDNA sequence homology analysis. The degradation capability of the strain YJB3 was investigated by incubation in mineral salt medium containing di-n-butyl-phthalate (DBP), one of important PAEs under different environmental conditions, showing 82.5% of the DBP removal in 5days of incubation under the optimum conditions (acetate 1.2g·L -1 , inocula 1.8%, and temperature 34.2°C) achieved by two-step sequential optimization technologies. The DBP metabolites including mono-butyl phthalate (MBP), phthalic acid (PA), protocatechuic acid (PCA), etc. were determined by GC-MS. The PCA catabolic genes responsible for the aromatic ring cleavage of PCA in the strain YJB3 were excavated by whole-genome sequencing. Thus, a degradation pathway of DBP by the strain YJB3 was proposed that MBP was formed, followed by PA, and then the intermediates were further utilized till complete degradation. To our knowledge, this is the first study to show the biodegradation of PAEs using endophyte. The results in the present study suggest that the strain YJB3 is greatly promising to act as a competent inoculum in removal of PAEs in both soils and crops. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Comparative study of safety and efficacy of synthetic surgical glue for mesh fixation in ventral rectopexy.

    PubMed

    Silveira, Raquel Kelner; Domingie, Sophie; Kirzin, Sylvain; de Melo Filho, Djalma Agripino; Portier, Guillaume

    2017-10-01

    Ventral mesh rectopexy (VMR) is a surgical option to treat rectal prolapse with pelvic floor dysfunction (PFD). Using synthetic surgical glue to fix the mesh to the anterior rectal wall after ventral dissection could be advantageous in comparison with sutured or stapled fixation. This study aimed to evaluate the safety and efficacy of synthetic surgical glue for mesh fixation compared with suture mesh fixation in VMR. This observational cohort study is a retrospective analysis conducted in a University Hospital Pelvic Surgery Center. All consecutive female patients (n = 176) who underwent laparoscopic or laparotomic VMR between January 2009 and December 2014 were included. Two groups were defined based on mesh fixation technique of the rectal wall: VMR with synthetic glue (n = 66) and VMR with suture (n = 110). The recurrence-free survival after VMR was determined by Kaplan-Meier method and multivariate analysis by Cox regression. Short-term postoperative complications, postoperative symptom improvement, the need for complementary treatment postoperatively, and procedure length were evaluated. A total of 176 females patients (mean age, 58.6 ± 13.7 years) underwent VMR with synthetic mesh. Mean recurrence-free survivals after VMR were 17.16 (CI 95% 16.54-17.80) and 17.33 (CI 95% 16.89-17.77) months in the glue group and the suture group, respectively (p > 0.05). Cox regression identified an independent effect on the recurrence risk of the external rectal prolapse, alone, or in combination with other anatomical abnormalities (HR = 0.37; CI 95% 0.14-0.93; p = 0.03). There was no significant difference of short-term postoperative morbidity, procedure length, postoperative symptom improvement, or need for complementary treatment postoperatively between suture versus glue groups (all p > 0.05). Use of glue to fix the mesh in VMR was safe and had no impact on outcomes. External prolapse was the unique significant predictive factor for

  10. Critical Speed of The Glass Glue Machine's Creep and Influence Factors Analysis

    NASA Astrophysics Data System (ADS)

    Yang, Jianxi; Huang, Jian; Wang, Liying; Shi, Jintai

    When automatic glass glue machine works, two questions of the machine starting vibrating and stick-slip motion are existing. These problems should be solved. According to these questions, a glue machine's model for studying stick-slip is established. Based on the dynamics system describing of the model, mathematical expression is presented. The creep critical speed expression is constructed referring to existing research achievement and a new conclusion is found. The influencing factors of stiffness, dampness, mass, velocity, difference of static and kinetic coefficient of friction are analyzed through Matlab simulation. Research shows that reasonable choice of influence parameters can improve the creep phenomenon. These all supply the theory evidence for improving the machine's motion stability.

  11. Healing of rabbit calvarial critical-sized defects using autogenous bone grafts and fibrin glue.

    PubMed

    Lappalainen, Olli-Pekka; Korpi, Riikka; Haapea, Marianne; Korpi, Jarkko; Ylikontiola, Leena P; Kallio-Pulkkinen, Soili; Serlo, Willy S; Lehenkari, Petri; Sándor, George K

    2015-04-01

    This study aimed to evaluate ossification of cranial bone defects comparing the healing of a single piece of autogenous calvarial bone representing a bone flap as in cranioplasty compared to particulated bone slurry with and without fibrin glue to represent bone collected during cranioplasty. These defect-filling materials were then compared to empty control cranial defects. Ten White New Zealand adult male rabbits had bilateral critical-sized calvarial defects which were left either unfilled as control defects or filled with a single full-thickness piece of autogenous bone, particulated bone, or particulated bone combined with fibrin glue. The defects were left to heal for 6 weeks postoperatively before termination. CT scans of the calvarial specimens were performed. Histomorphometric assessment of hematoxylin-eosin- and Masson trichrome-stained specimens was used to analyze the proportion of new bone and fibrous tissue in the calvarial defects. There was a statistically significant difference in both bone and soft tissue present in all the autogenous bone-grafted defect sites compared to the empty negative control defects. These findings were supported by CT scan findings. While fibrin glue combined with the particulated bone seemed to delay ossification, the healing was more complete compared to empty control non-grafted defects. Autogenous bone grafts in various forms such as solid bone flaps or particulated bone treated with fibrin glue were associated with bone healing which was superior to the empty control defects.

  12. Lifetime Improvement of Organic Light Emitting Diodes using LiF Thin Film and UV Glue Encapsulation

    NASA Astrophysics Data System (ADS)

    Huang, Jian-Ji; Su, Yan-Kuin; Chang, Ming-Hua; Hsieh, Tsung-Eong; Huang, Bohr-Ran; Wang, Shun-Hsi; Chen, Wen-Ray; Tsai, Yu-Sheng; Hsieh, Huai-En; Liu, Mark O.; Juang, Fuh-Shyang

    2008-07-01

    This work demonstrates the use of lithium fluoride (LiF) as a passivation layer and a newly developed UV glue for encapsulation on the LiF passivation layer to enhance the stability of organic light-emitting devices (OLEDs). Devices with double protective layers showed a 25-fold increase in operational lifetime compared to those without any packaging layers. LiF has a low melting point and insulating characteristics and it can be adapted as both a protective layer and pre-encapsulation film. The newly developed UV glue has a fast curing time of only 6 s and can be directly spin-coated onto the surface of the LiF passivation layer. The LiF thin film plus spin-coated UV glue is a simple packaging method that reduces the fabrication costs of OLEDs.

  13. Solvent extraction of tellurium from chloride solutions using tri-n-butyl phosphate: conditions and thermodynamic data.

    PubMed

    Li, Dongchan; Guo, Yafei; Deng, Tianlong; Chen, Yu-Wei; Belzile, Nelson

    2014-01-01

    The extractive separation of tellurium (IV) from hydrochloric acid media with tri-n-butyl phosphate (TBP) in kerosene was investigated. The dependence on the extraction of tellurium species, concentrations of tellurium and TBP, extraction time and stage, organic/aqueous ratio, and interferences from coexist metallic ions were examined and are discussed. Besides, the stripping agent and stripping time were also studied. It was found that the extraction reaction corresponds to the neutral complex formation mechanism and the extracted species is TeCl4 · 3TBP and that the extraction process is exothermic. The thermodynamic parameters of enthalpy (ΔH), entropy (ΔS), and free energy (ΔG) of the extraction process were evaluated at -26.2 kJ · mol(-1), -65.6 J · mol(-1) · K(-1), and -7.0 kJ · mol(-1), respectively at 293 K.

  14. Generalized Likelihood Uncertainty Estimation (GLUE) Using Multi-Optimization Algorithm as Sampling Method

    NASA Astrophysics Data System (ADS)

    Wang, Z.

    2015-12-01

    For decades, distributed and lumped hydrological models have furthered our understanding of hydrological system. The development of hydrological simulation in large scale and high precision elaborated the spatial descriptions and hydrological behaviors. Meanwhile, the new trend is also followed by the increment of model complexity and number of parameters, which brings new challenges of uncertainty quantification. Generalized Likelihood Uncertainty Estimation (GLUE) has been widely used in uncertainty analysis for hydrological models referring to Monte Carlo method coupled with Bayesian estimation. However, the stochastic sampling method of prior parameters adopted by GLUE appears inefficient, especially in high dimensional parameter space. The heuristic optimization algorithms utilizing iterative evolution show better convergence speed and optimality-searching performance. In light of the features of heuristic optimization algorithms, this study adopted genetic algorithm, differential evolution, shuffled complex evolving algorithm to search the parameter space and obtain the parameter sets of large likelihoods. Based on the multi-algorithm sampling, hydrological model uncertainty analysis is conducted by the typical GLUE framework. To demonstrate the superiority of the new method, two hydrological models of different complexity are examined. The results shows the adaptive method tends to be efficient in sampling and effective in uncertainty analysis, providing an alternative path for uncertainty quantilization.

  15. The diced cartilage glue graft for nasal augmentation. Morphometric evidence of longevity.

    PubMed

    Tasman, Abel-Jan; Diener, Pierre-André; Litschel, Ralph

    2013-03-01

    A grafting technique that uses diced cartilage without fascia, which improves formability while maintaining long-term stability, would be a welcome addition to the rhinoplasty armamentarium. A diced cartilage glue graft was recently introduced as the Tasman technique. The technique has been used by one of us (A.-J.T.) in 28 patients who were monitored clinically for 4 to 26 months. Sonographic morphometry of the graft was used in 10 patients with a maximum follow-up of 15 months, and 2 biopsies were obtained for histologic examination. Fashioning the diced cartilage glue graft reduced operating time compared with the diced cartilage fascia graft and allowed for a wide variety of transplant shapes and sizes, depending on the mold used. All grafts were used for augmentation of the nasal dorsum or radix and healed uneventfully. Sonographic cross-section measures of the grafts changed between 6% and –29%(median, –5%) in the early postoperative phase and 8%and –7% (median, –2%) between 3 and 15 months after insertion. Histologic examination of the graft biopsies revealed viable cartilage with signs of regeneration. The diced cartilage glue graft may become an attractive alternative to accepted methods for dorsal augmentation, the diced cartilage fascia graft in particular.

  16. Glue-Sniffing: A Comparison Study of Sniffers and Non-Sniffers.

    ERIC Educational Resources Information Center

    Jansen, P.; And Others

    1992-01-01

    Compared 22 glue sniffers and 22 nonsniffers from group of street children and adolescents living in supervised shelters. Found no statistically significant differences between groups on cognitive measures or biographical features. Shelter staff rated sniffers as significantly more disturbed in their relationships with others, although…

  17. Recurrent pyriform sinus fistula successfully treated by endoscopic Glubran 2 sealing: A rare case and literature review.

    PubMed

    Di Nardo, Giovanni; Valentini, Valentino; Angeletti, Diletta; Frediani, Simone; Iannella, Giannicola; Cozzi, Denis; Roggini, Mario; Magliulo, Giuseppe

    2016-01-01

    The authors present the case of a 3-year-old girl with a history of complicated surgery for removing a third branchial cleft fistula. An endoscopic approach using N-butyl-2-acrylate and metacrilosisolfolane glue (GLUBRAN 2) to seal the fistula was performed. The clinical and radiological 6-year follow-up confirmed the absence of the fistulous orifice and the persistence of scar due to previous open-neck surgical procedures. endoscopic Glubran 2 sealing has been an effective treatment procedure for branchial fistula.

  18. Mussel glue protein has an open conformation.

    PubMed

    Williams, T; Marumo, K; Waite, J H; Henkens, R W

    1989-03-01

    Both native glue protein from marine mussels and a synthetic nonhydroxylated analog were analyzed by far-uv CD under a variety of conditions. Analysis of the CD spectra using various models strongly suggest a primarily random coil structure for both forms of the protein, a fact also supported by the absence of spectral change for the glue protein upon dilution into 6 M guanidine hydrochloride. The nonhydroxylated analog, which consists of 20 repeats of the peptide sequence Ala-Lys-Pro-Ser-Tyr-Pro-Pro-Thr-Tyr-Lys, was further characterized by enzyme modification using mushroom tyrosinase. Enzymatic hydroxylation of tyrosines was found to be best fit by a model containing two rate constants, 5.6 (+/- 0.6) X 10(-3) and 7.2 (+/- 0.3) X 10(-2) min-1. At equilibrium, HPLC analysis of digests showed nearly 100% conversion of Tyr-9 and only 15 to 35% conversion of Tyr-5. The Chou and Fasman rules for predicting structure were applied to the repeat sequence listed above. The rules predict the absence of alpha helix and beta pleated sheets in the structure of this peptide. On the other hand, beta turns are predicted to be present with Tyr-5 being in the region of highest probability. These data suggest that the protein in solution has only a small amount of secondary structure.

  19. A Comparative Study of the Effect of Fibrin Glue versus Sutures on Clinical Outcome in Patients Undergoing Pterygium Excision and Conjunctival Autografts

    PubMed Central

    Cha, Dong Min; Kim, Kyeong Hwan; Choi, Hyuk Jin; Wee, Won Ryang

    2012-01-01

    Purpose To compare the effect of using fibrin glue or 10-0 nylon sutures on the clinical outcome of patients undergoing pterygium excision and conjunctival autografting. Methods We retrospectively reviewed the medical records of 52 eyes from 46 patients who underwent pterygium excision and conjunctival autografting and were followed up for more than 3 months. The operation duration, postoperative inflammation, complications, and recurrence rates were compared between groups of 20 patients (22 eyes) for whom fibrin glue was used (fibrin glue group) and 26 patients (30 eyes) for whom suturing was performed with 10-0 nylon (suture group) in pterygium excision and conjunctival autografting. Results The operation duration was 27.71 (5.22) minutes in the fibrin glue group and 43.30 (8.18) minutes in the suture group (p = 0.000). Seven days after the operation, the fibrin glue group showed milder conjunctival inflammation than the suture group (p = 0.000). Postoperative complications and corneal recurrence rates were not statistically different between the two groups. Conclusions The use of fibrin glue in pterygium excision with conjunctival autografting is likely to be a more effective, safer procedure than suturing. PMID:23204794

  20. ONYX versus n-BCA for embolization of cranial dural arteriovenous fistulas.

    PubMed

    Rabinov, James David; Yoo, Albert J; Ogilvy, Christopher S; Carter, Bob S; Hirsch, Joshua A

    2013-07-01

    To evaluate the efficacy of n-butyl-2-cyanoacrylate (Trufill n-BCA) versus ethylene vinyl alcohol copolymer (ONYX) for the embolization of cranial dural arteriovenous fistulas (DAVF). Fifty-three consecutive patients with cranial dural AVF were treated with liquid embolic agents from November, 2003 to November, 2008. These 53 patients had 56 lesions treated with arterial embolization. Patients embolized to completion underwent follow-up angiography at 3 months to assess for durable occlusion. Twenty-one lesions were treated with n-BCA. Seven patients treated with n-BCA had initial angiographic occlusion of their DAVF, which were durable at 3 months. Six patients had adjunctive treatment with coils and/or polyvinyl alcohol particles, but none of these were occluded by endovascular treatment alone. Eleven patients underwent post-embolization surgery for closure of their DAVF. There was one death related to intractable status epilepticus at presentation. One patient developed a major stroke from venous sinus thrombosis after embolization. Thirty-five lesions were treated with ONYX in 34 patients. Twenty-nine patients treated with ONYX had initial angiographic occlusion of their DAVF by embolization alone. One patient had recurrence at 3 months and was re-treated out of 27 total follow-ups. Four patients underwent post-embolization surgical obliteration of their lesions. No deaths or major strokes occurred in this cohort. Initial angiographic occlusion (p=0.0004) and durable angiographic occlusion (p=0.0018) rates for embolization of cranial DAVF show a statistically significant higher efficacy with ONYX compared with n-BCA. Patients embolized with ONYX underwent surgery less frequently compared with those treated with n-BCA (p=0.0015).

  1. Brown algae hydrolysis in 1-n-butyl-3-methylimidazolium chloride with mineral acid catalyst system.

    PubMed

    Malihan, Lenny B; Nisola, Grace M; Chung, Wook-Jin

    2012-08-01

    The amenability of three brown algal species, Sargassum fulvellum, Laminaria japonica and Undaria pinnatifida, to hydrolysis were investigated using the ionic liquid (IL), 1-n-butyl-3-methylimidazolium chloride ([BMIM]Cl). Compositional analyses of the brown algae reveal that sufficient amounts of sugars (15.5-29.4 wt.%) can be recovered. Results from hydrolysis experiments show that careful selection of the type of mineral acid as catalyst and control of acid loading could maximize the recovery of sugars. Optimal reaction time and temperature were determined from the kinetic studies on the sequential reducing sugar (TRS) formation and degradation. Optimal reaction times were determined based on the extent of furfurals formation as TRS degradation products. X-ray diffraction and environmental scanning electron microscopy confirmed the suitability of [BMIM]Cl as solvent for the hydrolysis of the three brown algae. Overall results show the potential of brown algae as renewable energy resources for the production of valuable chemicals and biofuels. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Construction of a Corneal Stromal Equivalent with SMILE-Derived Lenticules and Fibrin Glue.

    PubMed

    Yin, Houfa; Qiu, Peijin; Wu, Fang; Zhang, Wei; Teng, Wenqi; Qin, Zhenwei; Li, Chao; Zhou, Jiaojie; Fang, Zhi; Tang, Qiaomei; Fu, Qiuli; Ma, Jian; Yang, Yabo

    2016-09-21

    The scarcity of corneal tissue to treat deep corneal defects and corneal perforations remains a challenge. Currently, small incision lenticule extraction (SMILE)-derived lenticules appear to be a promising alternative for the treatment of these conditions. However, the thickness and toughness of a single piece of lenticule are limited. To overcome these limitations, we constructed a corneal stromal equivalent with SMILE-derived lenticules and fibrin glue. In vitro cell culture revealed that the corneal stromal equivalent could provide a suitable scaffold for the survival and proliferation of corneal epithelial cells, which formed a continuous pluristratified epithelium with the expression of characteristic markers. Finally, anterior lamellar keratoplasty in rabbits demonstrated that the corneal stromal equivalent with decellularized lenticules and fibrin glue could repair the anterior region of the stroma, leading to re-epithelialization and recovery of both transparency and ultrastructural organization. Corneal neovascularization, graft degradation, and corneal rejection were not observed within 3 months. Taken together, the corneal stromal equivalent with SMILE-derived lenticules and fibrin glue appears to be a safe and effective alternative for the repair of damage to the anterior cornea, which may provide new avenues in the treatment of deep corneal defects or corneal perforations.

  3. Cellulose pretreatment with 1-n-butyl-3-methylimidazolium chloride for solid acid-catalyzed hydrolysis.

    PubMed

    Kim, Soo-Jin; Dwiatmoko, Adid Adep; Choi, Jae Wook; Suh, Young-Woong; Suh, Dong Jin; Oh, Moonhyun

    2010-11-01

    This study has been focused on developing a cellulose pretreatment process using 1-n-butyl-3-methylimidazolium chloride ([bmim]Cl) for subsequent hydrolysis over Nafion(R) NR50. Thus, several pretreatment variables such as the pretreatment period and temperature, and the [bmim]Cl amount were varied. Additionally, the [bmim]Cl-treated cellulose samples were characterized by X-ray diffraction analysis, and their crystallinity index values including CI(XD), CI(XD-CI) and CI(XD-CII) were then calculated. When correlated with these values, the concentrations of total reducing sugars (TRS) obtained by the pretreatment of native cellulose (NC) and glucose produced by the hydrolysis reaction were found to show a distinct relationship with the [CI(NC)-CI(XD)] and CI(XD-CII) values, respectively. Consequently, the cellulose pretreatment step with [bmim]Cl is to loosen a crystalline cellulose through partial transformation of cellulose I to cellulose II and, furthermore, the TRS release, while the subsequent hydrolysis of [bmim]Cl-treated cellulose over Nafion(R) NR50 is effective to convert cellulose II to glucose. Copyright 2010 Elsevier Ltd. All rights reserved.

  4. Treatment of type II endoleak using Onyx with long-term imaging follow-up.

    PubMed

    Khaja, Minhaj S; Park, Auh Whan; Swee, Warren; Evans, Avery J; Fritz Angle, J; Turba, Ulku C; Sabri, Saher S; Matsumoto, Alan H

    2014-06-01

    The purpose of our study is to report our experience with the use of an ethylene vinyl alcohol copolymer (Onyx) in an off-label fashion for the treatment of type II endoleak after endovascular repair of the thoracic (TEVAR) and abdominal (EVAR) aorta. A retrospective review of patients with type I and/or II endoleak treated with Onyx was performed. Data regarding the technical, clinical, and imaging outcomes were collected. Technical success was defined as decreased or eliminated endoleak on the first imaging follow-up. Clinical success was defined as unchanged or decreased aneurysm sac size on subsequent follow-up. Eighteen patients (15 male, 3 female) with a mean age of 79 years (range 69-92) met inclusion criteria (16 abdominal aortic aneurysm, 2 thoracic aortic aneurysm). Sixteen patients had type II endoleak, and 2 had complex type II endoleak with a type I component. The interval between endograft placement and treatment was a mean of 30 months. Direct sac treatment approach was used in 13 patients; transarterial approach was used in 3 patients. Seven patients required the use of coils, N-butyl cyanoacrylate glue, or Amplatzer vascular plugs. The average volume of Onyx used per treatment was 5.6 mL (range 2.5-13). Duration of imaging follow-up was 0.75-72.5 months (mean 32.8). Sixteen of 18 (88.9 %) patients had initial technical and clinical success. Two of 18 patients (11.1 %) were initial technical failures, and 1 remained a failure despite a second treatment and attempted surgical ligation. Eight of 18 (44.4 %) of patients eventually required a second intervention, 5 (27.8 %) of them due to delayed clinical failure. Complications included 1 psoas hematoma, 1 transient L2 nerve paresis, and 1 intraperitoneal Onyx leak; all of these were without clinical sequelae. Onyx with or without coil/glue/Amplatzer plug embolization is safe and useful in the treatment of type II endoleak after TEVAR and EVAR. However, long-term clinical and imaging follow-up is needed

  5. 9 CFR 95.9 - Glue stock; requirements for unrestricted entry.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Glue stock; requirements for unrestricted entry. 95.9 Section 95.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EXPORTATION AND IMPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS...

  6. 9 CFR 95.9 - Glue stock; requirements for unrestricted entry.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Glue stock; requirements for unrestricted entry. 95.9 Section 95.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EXPORTATION AND IMPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS...

  7. Gravity: The Glue of the Universe. History and Activities.

    ERIC Educational Resources Information Center

    Gilbert, Harry; Smith, Diana Gilbert

    This book presents a story of the history of gravity, the glue of the universe, and is based on two premises: (1) an understanding of mathematics is not required to grasp the concepts and implications of relativity; and (2) relativity has altered forever the perceptions of gravity, space, time, and how the universe works. A narrative text section…

  8. Hypokalemic muscular paralysis causing acute respiratory failure due to rhabdomyolysis with renal tubular acidosis in a chronic glue sniffer.

    PubMed

    Kao, K C; Tsai, Y H; Lin, M C; Huang, C C; Tsao, C Y; Chen, Y C

    2000-01-01

    A 34-year-old male was admitted to the emergency department with the development of quadriparesis and respiratory failure due to hypokalemia after prolonged glue sniffing. The patient was subsequently given mechanical ventilatory support for respiratory failure. He was weaned from the ventilator 4 days later after potassium replacement. Toluene is an aromatic hydrocarbon found in glues, cements, and solvents. It is known to be toxic to the nervous system, hematopoietic system, and causes acid-base and electrolyte disorders. Acute respiratory failure with hypokalemia and rhabdomyolysis with acute renal failure should be considered as potential events in a protracted glue sniffing.

  9. Evaluating the use of fibrin glue for sealing low-output enterocutaneous fistulas: study protocol for a randomized controlled trial.

    PubMed

    Wu, Xiuwen; Ren, Jianan; Wang, Gefei; Wang, Jianzhong; Wang, Feng; Fan, Yueping; Li, Yuanxin; Han, Gang; Zhou, Yanbing; Song, Xiaofei; Quan, Bin; Yao, Min; Li, Jieshou

    2015-10-07

    The management of an enterocutaneous fistula poses a significant challenge to surgeons and is often associated with a costly hospital stay and long-term discomfort. The use of fibrin glue in the fistula tract has been shown to promote closure of low output enterocutaneous fistulas. Our previous nonrandomized study demonstrated that autologous platelet-rich fibrin glue treatment significantly decreased time to fistula closure and promoted closure rates. However, there are several limitations in the study, which may lead to bias in our conclusion. Thus, a multicenter, randomized, controlled clinical trial is required. The study is designed as a randomized, open-label, three-arm, multicenter study in nine Chinese academic hospitals for evaluating the efficacy and safety of fibrin glue for sealing low-output fistulas. An established number of 171 fistula patients will undergo prospective random assignment to autologous fibrin glue, commercial porcine fibrin sealants or drainage cessation (1:1:1). The primary endpoint is fistula closure time (defined as the interval between the day of enrollment and day of fistula closure) during the 14-day treatment period. To our knowledge, this is the first study to evaluate the safety and efficacy of both autologous and commercial fibrin glue sealing for patients with low-output volume fistulas. NCT01828892 . Registration date: April 2013.

  10. Using the DP-190 glue for adhesive attachment of a large space mirror and its rim

    NASA Astrophysics Data System (ADS)

    Vlasenko, Oleg; Zverev, Alexey; Sachkov, Mikhail

    2014-07-01

    The glue DP-190 is widely used for adhesive attachment of astrositall (zerodur) lightweight large-size space astronomical mirrors (diameter of 1.7 m and more) with elements of their frames of invar. Peculiarities of physicalmechanical behavior of the glue DP-190 when exposed to the environment during the ground operation and in orbit cause instability of the reflective surface quality of mirrors. In this report we show that even a small (around 1%-5%) volumetric deformation of a cylindrical adhesive layer with a thickness of 0.8 mm between the mirror and the rim element causes significant mirrors deformation. We propose to use adhesive layer of special form that allows to reduce volumetric deformations of the glue DP-190 up to three times. Here we present results based on primary mirror tests of the WSO-UV project.

  11. Emergency ultrasound-guided percutaneous embolization of post-traumatic bleeding hepatic artery pseudoaneurysms.

    PubMed

    Vyas, Sameer; Ahuja, Chirag Kamal; Yadav, Thakur Deen; Khandelwal, Niranjan

    2012-09-01

    Hepatic artery pseudoaneurysm (HAP) is an uncommon but serious complication of blunt trauma abdomen which can be managed by non-surgical interventional methods. We describe the case of a young boy with blunt trauma abdomen having a large hepatic laceration associated with two pseudoaneurysms of the hepatic artery branches. Both these HAPs were successfully managed by percutaneous injection of cyanoacrylate glue under sonographic guidance. A major surgery was thus averted. A brief review of the etiology, diagnosis and management of HAP including the present case is discussed.

  12. Using CV-GLUE procedure in analysis of wetland model predictive uncertainty.

    PubMed

    Huang, Chun-Wei; Lin, Yu-Pin; Chiang, Li-Chi; Wang, Yung-Chieh

    2014-07-01

    This study develops a procedure that is related to Generalized Likelihood Uncertainty Estimation (GLUE), called the CV-GLUE procedure, for assessing the predictive uncertainty that is associated with different model structures with varying degrees of complexity. The proposed procedure comprises model calibration, validation, and predictive uncertainty estimation in terms of a characteristic coefficient of variation (characteristic CV). The procedure first performed two-stage Monte-Carlo simulations to ensure predictive accuracy by obtaining behavior parameter sets, and then the estimation of CV-values of the model outcomes, which represent the predictive uncertainties for a model structure of interest with its associated behavior parameter sets. Three commonly used wetland models (the first-order K-C model, the plug flow with dispersion model, and the Wetland Water Quality Model; WWQM) were compared based on data that were collected from a free water surface constructed wetland with paddy cultivation in Taipei, Taiwan. The results show that the first-order K-C model, which is simpler than the other two models, has greater predictive uncertainty. This finding shows that predictive uncertainty does not necessarily increase with the complexity of the model structure because in this case, the more simplistic representation (first-order K-C model) of reality results in a higher uncertainty in the prediction made by the model. The CV-GLUE procedure is suggested to be a useful tool not only for designing constructed wetlands but also for other aspects of environmental management. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Determination of arsenic species in solid matrices utilizing supercritical fluid extraction coupled with gas chromatography after derivatization with thioglycolic acid n-butyl ester.

    PubMed

    Wang, Zhifeng; Cui, Zhaojie

    2016-12-01

    A method using derivatization and supercritical fluid extraction coupled with gas chromatography was developed for the analysis of dimethylarsinate, monomethylarsonate and inorganic arsenic simultaneously in solid matrices. Thioglycolic acid n-butyl ester was used as a novel derivatizing reagent. A systematic discussion was made to investigate the effects of pressure, temperature, flow rate of the supercritical CO 2 , extraction time, concentration of the modifier, and microemulsion on extraction efficiency. The application for real environmental samples was also studied. Results showed that thioglycolic acid n-butyl ester was an effective derivatizing reagent that could be applied for arsenic speciation. Using methanol as modifier of the supercritical CO 2 can raise the extraction efficiency, which can be further enhanced by adding a microemulsion that contains Triton X-405. The optimum extraction conditions were: 25 MPa, 90°C, static extraction for 10 min, dynamic extraction for 25 min with a flow rate of 2.0 mL/min of supercritical CO 2 modified by 5% v/v methanol and microemulsion. The detection limits of dimethylarsinate, monomethylarsonate, and inorganic arsenic in solid matrices were 0.12, 0.26, and 1.1 mg/kg, respectively. The optimized method was sensitive, convenient, and reliable for the extraction and analysis of different arsenic species in solid samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Clinical evaluations of complete autologous fibrin glue, produced by the CryoSeal® FS system, and polyglycolic acid sheets as wound coverings after oral surgery.

    PubMed

    Kouketsu, Atsumu; Nogami, Shinnosuke; Yamada-Fujiwara, Minami; Nagai, Hirokazu; Yamauchi, Kensuke; Mori, Shiro; Miyashita, Hitoshi; Kawai, Tadashi; Matsui, Aritsune; Kataoka, Yoshihiro; Satomi, Norihisa; Ezoe, Yushi; Abe, Satoko; Takeda, Yuri; Tone, Takeshi; Hirayama, Bunnichi; Kurobane, Tsuyoshi; Tashiro, Kazuki; Yanagisawa, Yuta; Takahashi, Tetsu

    2017-09-01

    The CryoSeal ® FS System has been recently introduced as an automated device for the production of complete fibrin glue from autologous plasma, rather than from pool allogenic or cattle blood, to prevent viral infection and allergic reaction. We evaluated the effectiveness of complete autologous fibrin glue and polyglycolic acid (PGA) sheet wound coverings in mucosa defect oral surgery. Postoperative pain, scar contracture, ingestion, tongue dyskinesia, and postoperative bleeding were evaluated in 12 patients who underwent oral (including the tongue) mucosa excision, and received a PGA sheet and an autologous fibrin glue covering. They were compared with 12 patients who received a PGA sheet and commercial allogenic fibrin glue. All cases in the complete autologous fibrin glue group demonstrated good wound healing without complications such as local infection or incomplete cure. All evaluated clinical measures in this group were similar or superior to the commercial allogenic fibrin glue group. Coagulation and adhesion quality achieved with this method was comparable to that with a PGA sheet and commercial fibrin glue. Covering oral surgery wounds with complete autologous fibrin glue produced by an automated device was convenient, safe, and reduced the risk of viral infection and allergic reaction associated with conventional techniques. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Tetra­butyl­ammonium tetra­kis­(trimethyl­silanolato-κO)ferrate(III)

    PubMed Central

    Hay, Michael; Staples, Richard; Lee, Andre

    2012-01-01

    In the title salt, (C16H36N)[Fe(C3H9OSi)4], the cation contains a central N atom bonded to four n-butyl alkyl groups in a tetra­hedral arrangement, while the anion contains a central FeIII atom tetra­hedrally coordinated by four trimethyl­silanolate ligands. PMID:22969479

  16. Effect of low-level laser therapy (LLLT) on peripheral nerve regeneration using fibrin glue derived from snake venom.

    PubMed

    Buchaim, Rogerio Leone; Andreo, Jesus Carlos; Barraviera, Benedito; Ferreira Junior, Rui Seabra; Buchaim, Daniela Vieira; Rosa Junior, Geraldo Marco; de Oliveira, Alexandre Leite Rodrigues; de Castro Rodrigues, Antonio

    2015-04-01

    The purpose of this study was to assess whether the adhesive permits the collateral repair of axons originating from a vagus nerve to the interior of a sural nerve graft, and whether low-level laser therapy (LLLT) assists in the regeneration process. Study sample consisted of 32 rats randomly separated into three groups: Control Group (CG; n=8), from which the intact sural nerve was collected; Experimental Group (EG; n=12), in which one of the ends of the sural nerve graft was coapted to the vagus nerve using the fibrin glue; and Experimental Group Laser (EGL; n=12), in which the animals underwent the same procedures as those in EG with the addition of LLLT. Ten weeks after surgery, the animals were euthanized. Morphological analysis by means of optical and electron microscopy, and morphometry of the regenerated fibers were employed to evaluate the results. Collateral regeneration of axons was observed from the vagus nerve to the interior of the autologous graft in EG and EGL, and in CG all dimensions measured were greater and presented a significant difference in relation to EG and EGL, except for the area and thickness of the myelin sheath, that showed significant difference only in relation to the EG. The present study demonstrated that the fibrin glue makes axonal regeneration feasible and is an efficient method to recover injured peripheral nerves, and the use of low-level laser therapy enhances nerve regeneration. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Mesh fixation with glue versus suture for chronic pain and recurrence in Lichtenstein inguinal hernioplasty.

    PubMed

    Sun, Ping; Cheng, Xiang; Deng, Shichang; Hu, Qinggang; Sun, Yi; Zheng, Qichang

    2017-02-07

    Chronic pain following mesh-based inguinal hernia repair is frequently reported, and has a significant impact on quality of life. Whether mesh fixation with glue can reduce chronic pain without increasing the recurrence rate is still controversial. To determine whether tissue adhesives can reduce postoperative complications, especially chronic pain, with no increase in recurrence rate, compared with sutures for mesh fixation in Lichtenstein hernia repair. We searched the following electronic databases with no language restrictions: the Cochrane Central Register of Controlled Trials (CENTRAL; issue 4, 2016) in the Cochrane Library (searched 11 May 2016), MEDLINE Ovid (1986 to 11 May 2016), Embase Ovid (1986 to 11 May 2016), Science Citation Index (Web of Science) (1986 to 11 May 2016), CBM (Chinese Biomedical Database), CNKI (China National Knowledge Infrastructure), VIP (a full-text database in China), Wanfang databases. We also checked reference lists of identified papers (included studies and relevant reviews). We included all randomised and quasi-randomised controlled trials comparing glue versus sutures for mesh fixation in Lichtenstein hernia repair. Cluster-RCTs were also eligible. Two review authors extracted data and assessed the risk of bias independently. Dichotomous outcomes were expressed as odds ratio (OR) with 95% confidence intervals (CI). Continuous outcomes were expressed as mean differences (MD) with 95% CIs. Twelve trials with a total of 1932 participants were included in this review. The overall postoperative chronic pain in the glue group was reduced by 37% (OR 0.63, 95% CI 0.44 to 0.91; 10 studies, 1418 participants, low-quality evidence) compared with the suture group. However, the results changed when we conducted subgroup analysis with regard to the type of mesh. Subgroup analysis of included studies using lightweight mesh showed the reduction of chronic pain was less profound and insignificant (OR 0.77, 95% CI 0.50 to 1.17). Subgroup

  18. Butyl benzyl phthalate (BBP)

    Integrated Risk Information System (IRIS)

    Butyl benzyl phthalate ; CASRN 85 - 68 - 7 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinog

  19. Crystal structure of (2-{[(8-aminona-phthalen-1-yl)imino]-meth-yl}-4,6-di-tert-butyl-phenolato-κ3N,N',O)bromido-nickel(II).

    PubMed

    O'Brien, Patrick; Zeller, Matthias; Lee, Wei-Tsung

    2018-04-01

    The title compound, [NiBr(C 25 H 29 N 2 O)], contains an Ni II atom with a slightly distorted square-planar coordination environment defined by one O and two N atoms from the 2-{[(8-aminona-phthalen-1-yl)imino]-meth-yl}-4,6-di- tert -butyl-phenolate ligand and a bromide anion. The Ni-O and Ni-N bond lengths are slightly longer than those observed in the phenyl backbone counterpart, which can be attributed to the larger steric hindrance of the naphthyl group in the structure of the title compound. The mol-ecule as a whole is substanti-ally distorted, with both the planar naphthalene-1,8-di-amine and imino-meth-yl-phenolate substitutents rotated against the NiN 2 OBr plane by 38.92 (7) and 37.22 (8)°, respectively, giving the mol-ecule a twisted appearance. N-H⋯Br hydrogen bonds and N-H⋯C(π) contacts connect the mol-ecules into dimers, and additional C-H⋯Br contacts, C-H⋯π inter-actions, and an offset stacking inter-action between naphthyl units inter-connect these dimers into a three-dimensional network.

  20. Superficial temporal arteriovenous fistula as a complication of rhytidectomy.

    PubMed

    Kominami, Shushi; Watanabe, Akira; Akimoto, Masahiro; Kobayashi, Shiro; Teramoto, Akira

    2012-03-01

    A 67-year-old woman who had undergone rhytidectomy 5 years before her presentation experienced increasing pulsatile tinnitus on the left side that had begun 2 years earlier. Angiography revealed a direct arteriovenous fistula between the superficial temporal artery and superficial temporal vein in front of her left ear. There was a scar from the earlier cosmetic surgery at the site. The fistula was embolized with N-butyl cyanoacrylate, and her tinnitus disappeared. We posit that the fistula was a complication of rhytidectomy and that a small arteriovenous fistula formed at the time of surgery and enlarged over time. This case indicates that arteriovenous fistulae can occur as a delayed complication of cosmetic surgery.

  1. Solvent Extraction of Tellurium from Chloride Solutions Using Tri-n-butyl Phosphate: Conditions and Thermodynamic Data

    PubMed Central

    Li, Dongchan; Guo, Yafei; Deng, Tianlong; Chen, Yu-Wei

    2014-01-01

    The extractive separation of tellurium (IV) from hydrochloric acid media with tri-n-butyl phosphate (TBP) in kerosene was investigated. The dependence on the extraction of tellurium species, concentrations of tellurium and TBP, extraction time and stage, organic/aqueous ratio, and interferences from coexist metallic ions were examined and are discussed. Besides, the stripping agent and stripping time were also studied. It was found that the extraction reaction corresponds to the neutral complex formation mechanism and the extracted species is TeCl4 ·3TBP and that the extraction process is exothermic. The thermodynamic parameters of enthalpy (ΔH), entropy (ΔS), and free energy (ΔG) of the extraction process were evaluated at −26.2 kJ·mol−1, −65.6 J·mol−1 ·K−1, and −7.0 kJ·mol−1, respectively at 293 K. PMID:24757422

  2. A novel synthesis of (E)-3-methylthio-3-substituted arylamino-2-cyanoacrylates under microwave irradiation.

    PubMed

    Ouyang, Guiping; Song, Baoan; Zhang, Huiping; Yang, Song; Jin, Linhong; Li, Qianzhu; Hu, Deyu

    2005-10-31

    A facile synthesis of 3-methylthio-3-arylamino-2-cyanoacrylates from 3,3-dimethylthioacrylate and aromatic amines or amino pyridines has been achieved in moderate to high yields (64.0% ~ 93.5%) in 30 minutes at 50 degrees C under microwave irradiation. This method is very simple and the reaction conditions are mild, environmentally friendly and more importantly, quick. In the 3-(4,5-dimethylthiazol- 2-yl)-2,5-diphenyltetrazolium bromide (MTT) test, some of the title compounds were found to possess good antiproliferation activity towards PC3 cells.

  3. Nail Damage (Severe Onychodystrophy) Induced by Acrylate Glue: Scanning Electron Microscopy and Energy Dispersive X-Ray Investigations

    PubMed Central

    Pinteala, Tudor; Chiriac, Anca Eduard; Rosca, Irina; Larese Filon, Francesca; Pinteala, Mariana; Chiriac, Anca; Podoleanu, Cristian; Stolnicu, Simona; Coros, Marius Florin; Coroaba, Adina

    2017-01-01

    Background Scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) techniques have been used in various fields of medical research, including different pathologies of the nails; however, no studies have focused on obtaining high-resolution microscopic images and elemental analysis of disorders caused by synthetic nails and acrylic adhesives. Methods Damaged/injured fingernails caused by the use of acrylate glue and synthetic nails were investigated using SEM and EDX methods. Results SEM and EDX proved that synthetic nails, acrylic glue, and nails damaged by contact with acrylate glue have a different morphology and different composition compared to healthy human nails. Conclusions SEM and EDX analysis can give useful information about the aspects of topography (surface sample), morphology (shape and size), hardness or reflectivity, and the elemental composition of nails. PMID:28232921

  4. DI(N-BUTYL) PHTHALATE AND DIETHYLHEXYL PHTHALATE IN COMBINATION ALTER SEXUAL DIFFERENTIATION IN A CUMULATIVE MANNER AS A RESULT OF DEPRESSED FETAL TESTOSTERONE PRODUCTION AND INSL3 GENE EXPRESSION IN MALE RATS

    EPA Science Inventory

    Plasticizers di(n-butyl) phthalate (DBP) and diehtylhexyl phthalate (DEHP) have similar modes of action: in utero exposure reduces testosterone (T) production in fetal male rats, inhibits reproductive tract differentiation, and induces reproductive organ malformations. In utero e...

  5. N-n-butyl haloperidol iodide ameliorates hypoxia/reoxygenation injury through modulating the LKB1/AMPK/ROS pathway in cardiac microvascular endothelial cells.

    PubMed

    Lu, Binger; Wang, Bin; Zhong, Shuping; Zhang, Yanmei; Gao, Fenfei; Chen, Yicun; Zheng, Fuchun; Shi, Ganggang

    2016-06-07

    Endothelial cells are highly sensitive to hypoxia and contribute to myocardial ischemia/reperfusion injury. We have reported that N-n-butyl haloperidol iodide (F2) can attenuate hypoxia/reoxygenation (H/R) injury in cardiac microvascular endothelial cells (CMECs). However, the molecular mechanisms remain unclear. Neonatal rat CMECs were isolated and subjected to H/R. Pretreatment of F2 leads to a reduction in H/R injury, as evidenced by increased cell viability, decreased lactate dehydrogenase (LDH) leakage and apoptosis, together with enhanced AMP-activated protein kinase (AMPK) and liver kinase B1 (LKB1) phosphorylation in H/R ECs. Blockade of AMPK with compound C reversed F2-induced inhibition of H/R injury, as evidenced by decreased cell viability, increased LDH release and apoptosis. Moreover, compound C also blocked the ability of F2 to reduce H/R-induced reactive oxygen species (ROS) generation. Supplementation with the ROS scavenger N-acetyl-L-cysteine (NAC) reduced ROS levels, increased cell survival rate, and decreased both LDH release and apoptosis after H/R. In conclusion, our data indicate that F2 may mitigate H/R injury by stimulating LKB1/AMPK signaling pathway and subsequent suppression of ROS production in CMECs.

  6. Contribution of glue layer into epidermis sample fluorescence dynamics

    NASA Astrophysics Data System (ADS)

    Salomatina, Elena V.; Chernova, Svetlana P.; Pravdin, Alexander B.

    2000-04-01

    In this work, the temporal behavior of autofluorescence of epidermis samples under UV-irradiation has ben studied. The samples were prepared using surface epidermis stripping technique. Fluorescence spectra and kinetic curves of fluorescence intensity have been obtained. It has been concluded that the glue composition used allows the measurement of epidermis fluorescence dynamics with the first 60 min of experiment.

  7. Lessons learned from laser tissue soldering and fibrin glue pyeloplasty in an in vivo porcine model.

    PubMed

    Barrieras, D; Reddy, P P; McLorie, G A; Bägli, D; Khoury, A E; Farhat, W; Lilge, L; Merguerian, P A

    2000-09-01

    We compared sutured pyeloplasty to 2 newer techniques of tissue anastomosis, including laser soldered pyeloplasty using a diode laser with 50% albumin solder mixed with indocyanine green and fibrin glue. We performed 53 pyeloplasties in 50 pigs using suture, laser or fibrin glue. In the immediate group anastomotic leak pressure was measured immediately postoperatively, and then animals were euthanized. At 1, 3 and 4 weeks postoperatively a pressure flow study at 10 cc per minute in cm. H2O was performed, and tissue was sent for histological and collagen content analysis. In the immediate studies laser soldering achieved a significantly higher mean anastomotic leak pressure (50.5 +/- 15.1 cm. H2O) than sutured (17.3 +/- 5.4) or fibrin glued (3.5 +/- 1.5) repairs. In the 1, 2 and 4-week studies animals in the sutured pyeloplasty group had no complications, and all pressure flow studies except 1 were normal. However, in the laser soldered groups we observed 8 urinomas in 19 animals, and most occurred during the first part of our study. This complication was prevented by stopping urine flow at the anastomotic site at laser irradiation and by improving application of the solder. Of the 11 animals in which pressure flow studies were performed only 2 were obstructed. Of the 7 chronic fibrin glue group 4 animals had urinomas and 2 had unobstructed pressure flow studies. Histological studies and immunohistochemical staining for collagen showed no differences in collagen distribution among the 3 procedures. Laser soldering and fibrin glue pyeloplasties are not superior in the long-term compared to sutured pyeloplasty. Fibrin glue in our animal model had the highest failure rate. Further improvements in the technical aspect of laser tissue welding need to be made to benefit from its theoretical advantages in minimally invasive surgery.

  8. Quantitative analysis of AgNOR proteins in buccal epithelial cells of Indian street boys addicted to gasp 'golden glue'.

    PubMed

    Mondal, Nandan Kumar; Ghosh, Sreenita; Ray, Manas Ranjan

    2011-11-01

    The effect of glue snuffle on the expression of argyrophilic nucleolar organizer regions (AgNORs), an indicator of ribosome biosynthesis, in epithelial cells of oral mucosa has been investigated. AgNOR was evaluated by cytochemical staining in 148 Indian street boys (median age 12 year) who had different bad addictions like tobacco smoking, chewing and most importantly inhaling glue and 20 age- and body mass index-matched school boys who had no such type of bad habit. Compared with school boys, glue addicted street boys showed remarkably increased number of AgNOR dots per nucleus (9.38±1.84 vs. 3.12±0.87, p<0.001), AgNOR size (1.34±0.52 vs. 0.43±0.02 μm(2), p<0.001) and percentage of AgNOR occupied nuclear area (9.38±2.12 vs. 0.99±0.03%, p<0.001). Increase in number and size of the dots is also higher in tobacco smokers and chewers when compared with school boys but a remarkable difference was recorded in glue addicted boys. The changes in AgNOR expression were positively associated with years of addiction after controlling potential confounders. Thus, glue snuffle appeared to be a risk factor for abnormal cell growth via up-regulation of ribosome biogenesis. Copyright © 2010 Elsevier GmbH. All rights reserved.

  9. Pro-osteogenic effects of fibrin glue in treatment of avascular necrosis of the femoral head in vivo by hepatocyte growth factor-transgenic mesenchymal stem cells

    PubMed Central

    2014-01-01

    Background Autologous transplantation of modified mesenchymal stem cells (MSCs) is a promising candidate for the treatment of the refractory clinical disease, avascular necrosis of the femoral head (ANFH). Our previous attempts by compounding MSCs with medical fibrin glue to treat ANFH in animal model have achieved excellent effects. However, the underlying molecular mechanism is unclear, especially on the transgenic gene expression. Methods Rabbit MSCs were isolated and compounded with fibrin glue. Following degrading of fibrin glue, proliferation, viability, expression of transgenic hepatocyte growth factor gene as well as osteogenic differentiation of MSCs were evaluated together with that of uncompounded MSCs. Fibrin glue-compounded MSCs were transplanted into the lesion of ANFH model, and the therapeutic efficacy was compared with uncompounded MSCs. One-Way ANOVA was used to determine the statistical significance among treatment groups. Results Fibrin glue compounding will not affect molecular activities of MSCs, including hepatocyte growth factor (HGF) secretion, cell proliferation and viability, and osteogenic differentiation in vitro. When applying fibrin glue-compounded MSCs for the therapy of ANFH in vivo, fibrin glue functioned as a drug delivery system and provided a sustaining microenvironment for MSCs which helped the relatively long-term secretion of HGF in the femoral head lesion and resulted in improved therapeutic efficacy when compared with uncompounded MSCs as indicated by hematoxylin-eosin staining and immunohistochemistry of osteocalcin, CD105 and HGF. Conclusion Transplantation of fibrin glue-compounding MSCs is a promising novel method for ANFH therapy. PMID:24885252

  10. Onyx versus nBCA and coils in the treatment of intracranial dural arteriovenous fistulas

    PubMed Central

    Choo, Douglas M

    2016-01-01

    Background and purpose Intracranial dural arteriovenous fistulas (DAVFs) with cortical venous drainage have significant morbidity and mortality. Complete closure of these lesions is necessary to reduce these risks. The purpose of our study was to compare the outcome of DAVFs treated with Onyx versus those treated with n-Butyl Cyanoacrylate (nBCA) and coil embolization in a case-control study. Compared with nBCA and coil embolization, we hypothesized that Onyx embolization for DAVF is safer and has a higher chance of complete obliteration, with no need for post-embolization surgery for the DAVF. Materials and methods From 1998 to 2015, 29 patients who had DAVFs were treated with endovascular embolization. Of these, 24 patients had imaging available for analysis. Successful closure rates, complications, and procedure time were compared between the embolization techniques. Results The chance of not requiring post-embolization surgery with Onyx (81.8%) was significantly higher (p = 0.005) than with nBCA (22.22%). The complication rate with Onyx (9.1%) tended to be lower compared with that of nBCA (22.22%; p = 0.37). Procedural time was not significantly different between Onyx (mean 267 minutes) and nBCA (mean 288 minutes) (p = 0.59). The odds ratio of a DAVF being treated with Onyx and then requiring no follow-up surgery was 17.5 (95% CI 1.97–155.4). Conclusion Our case-control study suggests that Onyx embolization is superior to nBCA and coil embolization in completely obliterating DAVFs, with higher odds of no post-embolization surgery. We also found that Onyx is safe for embolization of DAVFs, with no associated neurological mortality and morbidity. PMID:26748082

  11. Onyx versus nBCA and coils in the treatment of intracranial dural arteriovenous fistulas.

    PubMed

    Choo, Douglas M; Shankar, Jai Jai Shiva

    2016-04-01

    Intracranial dural arteriovenous fistulas (DAVFs) with cortical venous drainage have significant morbidity and mortality. Complete closure of these lesions is necessary to reduce these risks. The purpose of our study was to compare the outcome of DAVFs treated with Onyx versus those treated with n-Butyl Cyanoacrylate (nBCA) and coil embolization in a case-control study. Compared with nBCA and coil embolization, we hypothesized that Onyx embolization for DAVF is safer and has a higher chance of complete obliteration, with no need for post-embolization surgery for the DAVF. From 1998 to 2015, 29 patients who had DAVFs were treated with endovascular embolization. Of these, 24 patients had imaging available for analysis. Successful closure rates, complications, and procedure time were compared between the embolization techniques. The chance of not requiring post-embolization surgery with Onyx (81.8%) was significantly higher (p = 0.005) than with nBCA (22.22%). The complication rate with Onyx (9.1%) tended to be lower compared with that of nBCA (22.22%; p = 0.37). Procedural time was not significantly different between Onyx (mean 267 minutes) and nBCA (mean 288 minutes) (p = 0.59). The odds ratio of a DAVF being treated with Onyx and then requiring no follow-up surgery was 17.5 (95% CI 1.97-155.4). Our case-control study suggests that Onyx embolization is superior to nBCA and coil embolization in completely obliterating DAVFs, with higher odds of no post-embolization surgery. We also found that Onyx is safe for embolization of DAVFs, with no associated neurological mortality and morbidity. © The Author(s) 2016.

  12. Biological Glue Application in Repair of Atrioventricular Groove Rupture: A Case Report

    PubMed Central

    Durukan, Ahmet Baris; Serter, Fatih Tanzer; Gurbuz, Hasan Alper; Tavlasoglu, Murat; Ucar, Halil Ibrahim; Yorgancioglu, Cem

    2014-01-01

    Abstract Atrioventricular groove rupture is a rare, albeit mortal, complication following mitral valve surgery. Avoidance is the best strategy but it cannot fully prevent the occurrence of this complication. Several repair techniques have been described with varying success rates; however, the rarity of the complication precludes consensus about the safest technique. Here we report two cases of posterior atrioventricular groove rupture. Both cases were diagnosed immediately after the cessation of cardiopulmonary bypass. Repair was performed successfully with a technique involving the use of biological glue. The postoperative course was uneventful for both of them. Both cases are well with normally functioning mitral prostheses; one with a follow-up time of 5.5 years and the other 10 months. We believe that the glue provides additional hemostasis and support to the repaired area. PMID:25870633

  13. Construction of a Corneal Stromal Equivalent with SMILE-Derived Lenticules and Fibrin Glue

    PubMed Central

    Yin, Houfa; Qiu, Peijin; Wu, Fang; Zhang, Wei; Teng, Wenqi; Qin, Zhenwei; Li, Chao; Zhou, Jiaojie; Fang, Zhi; Tang, Qiaomei; Fu, Qiuli; Ma, Jian; Yang, Yabo

    2016-01-01

    The scarcity of corneal tissue to treat deep corneal defects and corneal perforations remains a challenge. Currently, small incision lenticule extraction (SMILE)-derived lenticules appear to be a promising alternative for the treatment of these conditions. However, the thickness and toughness of a single piece of lenticule are limited. To overcome these limitations, we constructed a corneal stromal equivalent with SMILE-derived lenticules and fibrin glue. In vitro cell culture revealed that the corneal stromal equivalent could provide a suitable scaffold for the survival and proliferation of corneal epithelial cells, which formed a continuous pluristratified epithelium with the expression of characteristic markers. Finally, anterior lamellar keratoplasty in rabbits demonstrated that the corneal stromal equivalent with decellularized lenticules and fibrin glue could repair the anterior region of the stroma, leading to re-epithelialization and recovery of both transparency and ultrastructural organization. Corneal neovascularization, graft degradation, and corneal rejection were not observed within 3 months. Taken together, the corneal stromal equivalent with SMILE-derived lenticules and fibrin glue appears to be a safe and effective alternative for the repair of damage to the anterior cornea, which may provide new avenues in the treatment of deep corneal defects or corneal perforations. PMID:27651001

  14. An overview on autologous fibrin glue in bone tissue engineering of maxillofacial surgery

    PubMed Central

    Khodakaram-Tafti, Azizollah; Mehrabani, Davood; Shaterzadeh-Yazdi, Hanieh

    2017-01-01

    The purpose of this review is to have an overview on the applications on the autologous fibrin glue as a bone graft substitute in maxillofacial injuries and defects. A search was conducted using the databases such as Medline or PubMed and Google Scholar for articles from 1985 to 2016. The criteria were “Autograft,” “Fibrin tissue adhesive,” “Tissue engineering,” “Maxillofacial injury,” and “Regenerative medicine.” Bone tissue engineering is a new promising approach for bone defect reconstruction. In this technique, cells are combined with three-dimensional scaffolds to provide a tissue-like structure to replace lost parts of the tissue. Fibrin as a natural scaffold, because of its biocompatibility and biodegradability, and the initial stability of the grafted stem cells is introduced as an excellent scaffold for tissue engineering. It promotes cell migration, proliferation, and matrix making through acceleration in angiogenesis. Growth factors in fibrin glue can stimulate and promote tissue repair. Autologous fibrin scaffolds are excellent candidates for tissue engineering so that they can be produced faster, cheaper, and in larger quantities. In addition, they are easy to use and the probability of viral or prion transmission may be decreased. Therefore, autologous fibrin glue appears to be promising scaffold in regenerative maxillofacial surgery. PMID:28584530

  15. A general contact mechanical formulation of multilayered structures and its application to deconvolute thickness/mechanical properties of glue used in surface force apparatus.

    PubMed

    Math, Souvik; Horn, Roger; Jayaram, Vikram; Biswas, Sanjay Kumar

    2007-04-15

    Currently data obtained from surface force apparatus experiments are convoluted with the mechanical response of glue of unknown thickness, used to bond mica sheets to the substrates. This paper describes a formulation to precisely deconvolute out the forces between the mica sheets by determining the thickness of glue, knowing the mechanical properties of the glue. The formulation consists of a general solution based on the noniterative Hankel transform of the Laplace equation. The generality is achieved by treating all the layers except the one in contact as an effective lumped system consisting of a set of springs in series, where each spring represents a layer. The solution is validated by nanoindentation of trilayer systems consisting of layers with widely diverse mechanical properties, some differing from each other by three orders of magnitude. SFA experiments are done with carefully metered slabs of glue. The proposed method is validated by comparing the actual glue thicknesses with those determined using the present analysis.

  16. OB glue paste technique for establishing nude mouse human gastric cancer orthotopic transplantation models

    PubMed Central

    Shi, Jun; Wei, Pin-Kang; Zhang, Shen; Qin, Zhi-Feng; Li, Jun; Sun, Da-Zhi; Xiao, Yan; Yu, Zhi-Hong; Lin, Hui-Ming; Zheng, Guo-Jing; Su, Xiao-Mei; Chen, Ya-Lin; Liu, Yan-Fang; Xu, Ling

    2008-01-01

    AIM: To establish nude mouse human gastric cancer orthotopic transplantation models using OB glue paste technique. METHODS: Using OB glue paste technique, orthotopic transplantation models were established by implanting SGC-7901 and MKN-45 human gastric cancer cell strains into the gastric wall of nude mice. Biological features, growth of the implanted tumors, the success rate of transplantation and the rate of auto-metastasis of the two models were observed. RESULTS: The success rates of orthotopic transplan-tation of the two models were 94.20% and 96%. The rates of hepatic metastasis, pulmonary metastasis, peritoneal metastasis, lymphocytic metastasis and splenic metastasis were 42.13% and 94.20%, 48.43% and 57.97%, 30.83% and 36.96%, 67.30% and 84.06%, and 59.75% and 10.53%, respectively. The occurrence of ascites was 47.80% and 36.96%. CONCLUSION: OB glue paste technique is easy to follow. The biological behaviors of the nude mouse human gastric cancer orthotopic transplantation models established with this technique are similar to the natural processes of growth and metastasis of human gastric cancer, and, therefore, can be used as an ideal model for experimental research of proliferative metastasis of tumors. PMID:18720543

  17. Percutaneous Glue Embolization of a Visceral Artery Pseudoaneurysm in a Case of Sickle Cell Anemia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gulati, Gurpreet S.; Gulati, Manpreet S.; Makharia, Govind

    2006-08-15

    Although aneurysmal complications of sickle cell anemia have been described in the intracranial circulation, visceral artery pseudoaneurysms in this disease entity have not previously been reported in the literature. Conventional treatment of visceral pseudoaneurysms has been surgical ligation or resection of the aneurysm. Transcatheter embolization has emerged as an attractive, minimally invasive alternative to surgery in the treatment of these lesions. In certain situations, however, due to the unfavorable angiographic anatomy precluding safe transcatheter embolization, direct percutaneous glue injection of the pseudoaneurysm sac may be considered to achieve successful occlusion of the sac. The procedure may be rendered safer bymore » simultaneous balloon protection of the parent artery. We describe this novel treatment modality in a case of inferior pancreaticoduodenal artery pseudoaneurysm in a patient with sickle cell anemia. Although a complication in the form of glue reflux into the parent vessel occurred that necessitated surgery, this treatment modality may be used in very selected cases (where conventional endovascular embolization techniques are not applicable) after careful selection of the balloon diameter and appropriate concentration of the glue-lipiodol mixture.« less

  18. A comparison of 2-octyl cyanoacrylate with nylon for wound closure of knee arthroscopy portals.

    PubMed

    Imbuldeniya, A M; Rashid, A; Murphy, J P

    2014-09-01

    To compare the cosmetic results, complications and patient satisfaction of 2-octyl cyanoacrylate (Dermabond, Ethicon Inc. Somerville, NJ, USA), a liquid bonding agent, with 3-0 nylon sutures (Ethilon, Ethicon Inc) skin closure in two groups of patients undergoing elective knee arthroscopy at 6 weeks. The retrospective clinical audit recruited patients undergoing knee surgery for the first time between October 2010 and August 2011. The patients were either treated with the liquid bonding agent or nylon sutures. The patients in the bonding agent group were allowed to shower as normal on postoperative day one, while patients in the suture group kept their wounds dry for 2 weeks. Between the two groups (40 patients per group) there was no difference in the cosmetic outcome (p=0.285), patient satisfaction (p=0.29), pain scores (p=0.44) or wound complication rate (p<0.05). Patient satisfaction was high in both groups. Furthermore, 83.75% of all patients indicated they would prefer the liquid bonding closure over nylon sutures if undergoing the same procedure in the future as they could shower the next day and avoid suture removal. 2-octyl cyanoacrylate is safe to use in the short term in knee arthroscopy providing comparable results to nylon suture closure. Allowing patients to shower the next day appears to cause no adverse effects. The authors would like to state that they do not have any economic or social interest in any of the products used or mentioned. No grant or finance was received for this study, nor any input from other sources.

  19. Biodegradation of di-n-Butyl Phthalate by Achromobacter sp. Isolated from Rural Domestic Wastewater.

    PubMed

    Jin, Decai; Kong, Xiao; Li, Yujie; Bai, Zhihui; Zhuang, Guoqiang; Zhuang, Xuliang; Deng, Ye

    2015-10-26

    A bacterial strain W-1, isolated from rural domestic wastewater, can utilize the environmental hormone di-n-butyl phthalate (DBP) as the sole carbon and energy source. The isolated bacterium species was confirmed to belong to the genus Achromobacter based on its 16S rRNA gene sequence. The results of substrate utilization tests showed that the strain W-1 could utilize other common phthalates and phenol. High-performance liquid chromatography analysis revealed that the optimal conditions for DBP degradation were pH 7.0, 35 °C, and an agitation rate of 175 rpm. Under these conditions, 500 mg/L of DBP was completely degraded within 30 h. The effects of heavy metals (50 mg/L Cu(2+) and 500 mg/L Pb(2+)) and surfactants (100 mg/L SDS and 500 mg/L Tween 20) on DBP degradation were investigated. The results demonstrated that Cu(2+) and SDS severely inhibited DBP degradation and Pb(2+) weakly inhibited DBP degradation, while Tween 20 greatly enhanced DBP degradation. Furthermore, phthalate degradation genes were found to be located on a plasmid present in Achromobacter sp. W-1.

  20. A sutureless technique using cyanoacrylate adhesives when creating a stoma for extremely low birth weight infants.

    PubMed

    Nose, Satoko; Sasaki, Takashi; Saka, Ryuta; Minagawa, Kyoko; Okuyama, Hiroomi

    2016-01-01

    Intestinal perforation and necrotizing enterocolitis (NEC) are neonatal intestinal emergencies that are especially common in premature infants. While prompt surgical intervention, including stoma creation, is often required, the optimal surgical treatment has been controversial because of the substantial risks related to the stoma creation and management. The use of a tissue adhesive may have some advantages over the use of sutures when creating an intestinal stoma in extremely low birth weight (ELBW) infants. The purpose of this report was to present a novel approach for creating a stoma using a tissue adhesive in ELBW infants. A total of eight ELBW infants that underwent laparotomy with the creation of intestinal stomas using cyanoacrylate adhesive at our institution between 2009 and 2014 were enrolled. The clinical parameters, including the length of the operation, intra- and postoperative complications and the outcomes were evaluated. The median body weight and gestational age at birth were 630 g and 24.3 weeks, respectively. The median age at referral was 11.5 days. The median length of the procedure was 58.5 min, including the inspection and resection of the intestine. All procedures were completed without any intraoperative complications. There were no postoperative complications associated with the stoma. Two patients died of the associated septic status. Sutureless enterostomy using cyanoacrylate adhesive is a simple technique which has the potential to reduce the incidence of complications related to the intestinal stoma in ELBW infants.

  1. 9 CFR 95.10 - Glue stock; importations permitted subject to restrictions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... disinfection by such method or methods as the Deputy Administrator, Veterinary Services may prescribe unless... permission by the Deputy Administrator, Veterinary Services glue stock may be stored for a temporary period... persons authorized by the Deputy Administrator, Veterinary Services so to do, or without sealing as...

  2. 9 CFR 95.10 - Glue stock; importations permitted subject to restrictions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... disinfection by such method or methods as the Deputy Administrator, Veterinary Services may prescribe unless... permission by the Deputy Administrator, Veterinary Services glue stock may be stored for a temporary period... persons authorized by the Deputy Administrator, Veterinary Services so to do, or without sealing as...

  3. Fibrin glue versus autologous blood for conjunctival autograft fixation in pterygium surgery.

    PubMed

    Boucher, Sophie; Conlon, Ronan; Teja, Salina; Teichman, Joshua C; Yeung, Season; Ziai, Setareh; Baig, Kashif

    2015-08-01

    To compare the outcomes between autologous blood- and fibrin glue-fixated conjunctival autografts in pterygium excision surgery. Retrospective case series. Forty eyes of 40 patients who had a primary nasal pterygium excision. A retrospective comparative case series of 40 eyes (40 patients) that had a primary nasal pterygium excision. All eyes had a conjunctival autograft from the superior bulbar conjunctiva to cover the scleral bed. Twenty eyes (20 patients) had fixation of the autograft using autologous blood (AB), and 20 eyes (20 patients) had fixation using fibrin glue (FG). One year of follow-up data included conjunctival graft stability (graft loss, graft retraction), pterygium recurrence, visual acuity, and postoperative complications. Descriptive and inferential statistics were performed. Intraoperatively, no complications occurred in either group. Graft loss occurred in 6 patients in the AB group, compared with none in the FG group. Graft retraction occurred in 3 patients in the AB group and 2 patients in the FG group. At 1 year postoperatively, pterygium recurrence occurred in 4 patients in the AB group and 1 patient in the FG group. One patient in the AB group developed a small pyogenic granuloma that resolved by 6 months with conservative management. Visual acuity remained stable in both groups. Conjunctival autograft fixation with autologous blood resulted in less stable conjunctival autografts and a higher recurrence rate compared with fixation with fibrin glue. Copyright © 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  4. Developing the Surface Chemistry of Transparent Butyl Rubber for Impermeable Stretchable Electronics.

    PubMed

    Vohra, Akhil; Carmichael, R Stephen; Carmichael, Tricia Breen

    2016-10-11

    Transparent butyl rubber is a new elastomer that has the potential to revolutionize stretchable electronics due to its intrinsically low gas permeability. Encapsulating organic electronic materials and devices with transparent butyl rubber protects them from problematic degradation due to oxygen and moisture, preventing premature device failure and enabling the fabrication of stretchable organic electronic devices with practical lifetimes. Here, we report a methodology to alter the surface chemistry of transparent butyl rubber to advance this material from acting as a simple device encapsulant to functioning as a substrate primed for direct device fabrication on its surface. We demonstrate a combination of plasma and chemical treatment to deposit a hydrophilic silicate layer on the transparent butyl rubber surface to create a new layered composite that combines Si-OH surface chemistry with the favorable gas-barrier properties of bulk transparent butyl rubber. We demonstrate that these surface Si-OH groups react with organosilanes to form self-assembled monolayers necessary for the deposition of electronic materials, and furthermore demonstrate the fabrication of stretchable gold wires using nanotransfer printing of gold films onto transparent butyl rubber modified with a thiol-terminated self-assembled monolayer. The surface modification of transparent butyl rubber establishes this material as an important new elastomer for stretchable electronics and opens the way to robust, stretchable devices.

  5. Evaluating the use of octyl-2-cyanoacrylate in unilateral cleft lip repair

    PubMed Central

    Malhotra, Vijaylaxmy; Dayashankara Rao, J. K.; Arya, Varun; Sharma, Shalender; Singh, Sushil; Luthra, Payal

    2016-01-01

    Background: Facial cosmetic results are one of the most concerning issues for the parents who get their children operated for cleft lip. Moreover, the postoperative care of the surgical site, the discomfort associated with the suture removal, and additional visit for suture removal are other reasons which encourages one to use any new technologies that may replace the need for suture placement. In this study, we used octyl-2-cyanoacrylate, a tissue adhesive which offers a viable alternative to traditional techniques without compromising optimal wound closure. Objective: To perform a comprehensive comparison of the outcomes from the use of Dermabond in patients undergoing primary repair of congenital cleft lip ± palate anomalies. Materials and Methods: Twenty patients, in the age group of 3–18 months were treated surgically for unilateral cleft lip deformity using Millard rotation-advancement flap. Pre- and post-operative photographs of the patients were taken at 1 week, 2 week, 1 month, 6 months, and 1 year postoperatively and were evaluated using Vancouver scar scale which was given by Sullivan in 1990. Paired t-test was used for statistical analysis. Results: Increased vascularity (hyperemia) was seen in the 1st and 2nd week in 35% and 30% patients, respectively which gradually reduced to normal in subsequent follow-ups. The scar was flat in 85% of patients in 1st week, and the number decreased to 10% at the end of 1 year. No wound dehiscence was found in any patients. Statistical analysis showed that among all the follow-ups, only the difference between the first and second follow-ups. Comparison of the results of 1 week with all other follow-ups yielded no significant results. Conclusion: Octyl-2-cyanoacrylate can be used for cleft lip closure effectively. The procedure is relatively painless and quick. Added to this are benefits of protection from wound infection since the material is bacteriostatic. PMID:28356686

  6. Immunity against mouse thymus-leukemia antigen (TL) protects against development of lymphomas induced by a chemical carcinogen, N-butyl-N-nitrosourea.

    PubMed

    Tsujimura, Kunio; Obata, Yuichi; Matsudaira, Yasue; Ozeki, Satoshi; Taguchi, Osamu; Nishida, Keiko; Okanami, Yuko; Akatsuka, Yoshiki; Kuzushima, Kiyotaka; Takahashi, Toshitada

    2004-11-01

    Mouse thymus-leukemia antigens (TL) are aberrantly expressed on T lymphomas in C57BL/6 (B6) and C3H/He (C3H) mice, while they are not expressed on normal T lymphocytes in these strains. When N-butyl-N-nitrosourea (NBU), a chemical carcinogen, was administered orally to B6 and C3H strains, lymphoma development was slower than in T3(b)-TL gene-transduced counterpart strains expressing TL ubiquitously as self-antigens, suggesting that anti-TL immunity may play a protective role. In addition, the development of lymphomas was slightly slower in C3H than in B6, which seems to be in accordance with the results of skin graft experiments indicating that both cellular and humoral immunities against TL were stronger in C3H than B6 mice. The interesting finding that B lymphomas derived from a T3(b)-TL transgenic strain (C3H background) expressing a very high level of TL were rejected in C3H, but not in H-2K(b) transgenic mice (C3H background), raises the possibility that TL-specific effector T cell populations are eliminated and/or energized to a certain extent by interacting with H-2K(b) molecules.

  7. Crystal structure of bis­{μ-(E)-2-[(2-oxido­phenyl­imino)­meth­yl]quinolin-8-olato-κ4 O,N,N′,O′}bis­[di­butyl­tin(IV)

    PubMed Central

    Carlos, Camacho-Camacho; Naytzé, Ortiz-Pastrana; Ariadna, Garza-Ortiz; Irma, Rojas-Oviedo

    2017-01-01

    Condensation of 8-hy­droxy­quinoline-2-carbaldehyde with 2-amino­phenol gave the (E)-2-[(2-hy­droxy­phenyl­imino)­meth­yl]quinolin-8-ol derivative that reacted with di-n-butyl­tin oxide with release of H2O to yield the chelate title complex, [Sn2(C4H9)4(C16H10N2O2)2]. The compound crystallizes in the triclinic space group P-1, with two independent centrosymmetric dimers in the unit cell. Each features a typical pincer-type structure where the dianionic ligand is tetra­dentate, coordinating to the central tin atom through both phenolate oxygen atoms, as well as through the quinoline and imine N atoms. Each metal atom adopts a distorted penta­gonal–bipyramidal SnC2N2O3 coordination arising from the N,N′,O,O′-tetra­dentate deprotonated Schiff base, one bridging phenolate O atom of the neighbouring ligand and two butyl groups in the axial sites. PMID:28083122

  8. 40 CFR 721.1577 - 1,4-Benzenedicarboxylic acid, bis [4-(ethenyloxy) butyl] ester.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-(ethenyloxy) butyl] ester. 721.1577 Section 721.1577 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Specific Chemical Substances § 721.1577 1,4-Benzenedicarboxylic acid, bis [4-(ethenyloxy) butyl] ester. (a... 1,4-benzenedicarboxylic acid, bis[4-(ethenyloxy) butyl] ester (PMN P-98-1163; CAS No. 117397-31-6...

  9. 40 CFR 721.1577 - 1,4-Benzenedicarboxylic acid, bis [4-(ethenyloxy) butyl] ester.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-(ethenyloxy) butyl] ester. 721.1577 Section 721.1577 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Specific Chemical Substances § 721.1577 1,4-Benzenedicarboxylic acid, bis [4-(ethenyloxy) butyl] ester. (a... 1,4-benzenedicarboxylic acid, bis[4-(ethenyloxy) butyl] ester (PMN P-98-1163; CAS No. 117397-31-6...

  10. Simultaneous analysis of tert-butylhydroquinone, tert-butylquinone, butylated hydroxytoluene, 2-tert-butyl-4-hydroxyanisole, 3-tert-butyl-4-hydroxyanisole, α-tocopherol, γ-tocopherol, and δ-tocopherol in edible oils by normal-phase high performance liquid chromatography.

    PubMed

    Li, Jun; Bi, Yanlan; Sun, Shangde; Peng, Dan

    2017-11-01

    A normal-phase high performance liquid chromatography method for the simultaneous determination of tert-butylhydroquinone, tert-butylquinone, butylated hydroxytoluene, 2-tert-butyl-4-hydroxyanisole, 3-tert-butyl-4-hydroxyanisole, α-tocopherol, γ-tocopherol, and δ-tocopherol in edible oils was investigated. A silica column was used to separate the analytes with the gradient elution. An ultraviolet-visible detector was set at dual wavelengths mode (280 and 310nm). The column temperature was 30°C. The analytes were directly extracted with methanol. Results showed that the normal-phase high performance liquid chromatography method performed well with wide liner ranges (0.10∼500.00μg/mL, R 2 >0.9998), low limits of detection and quantitation (below 0.40 and 1.21μg/mL, respectively), and good recoveries (81.38∼102.34% in soybean oils and 83.03∼100.79% in lard, respectively). The reduction of tert-butylquinone caused by the reverse-phase high performance liquid chromatography during the injection was avoided with the current normal-phase method. The two isomers of butylated hydroxyanisole can also be separated with good resolution. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Successful closure of chronic BPF by thoracoscopy after failure of endoscopic fibrin glue application and thoracoplasty.

    PubMed

    Tschopp, J M; Evéquoz, D; Karrer, W; Aymon, E; Naef, A P

    1990-03-01

    We report a case of chronic debilitating BPF following right upper lobe resection. Despite several endobronchial applications of fibrin glue, we could not close it. Since the patient was extremely debilitated by symptoms due to the BPF, a thoracoplasty was attempted but was not successful. Finally, the BPF was definitely closed by instillation of talc into the pleura through thoracoscopy. To our knowledge, this is the first reported case of chemical closure of a recalcitrant BPF by the route of thoracoscopy. It also shows the failure of endoscopic fibrin glue application in such a condition.

  12. Versatile fabrication of paper-based microfluidic devices with high chemical resistance using scholar glue and magnetic masks.

    PubMed

    Cardoso, Thiago M G; de Souza, Fabrício R; Garcia, Paulo T; Rabelo, Denilson; Henry, Charles S; Coltro, Wendell K T

    2017-06-29

    Simple methods have been developed for fabricating microfluidic paper-based analytical devices (μPADs) but few of these devices can be used with organic solvents and/or aqueous solutions containing surfactants. This study describes a simple fabrication strategy for μPADs that uses readily available scholar glue to create the hydrophobic flow barriers that are resistant to surfactants and organic solvents. Microfluidic structures were defined by magnetic masks designed with either neodymium magnets or magnetic sheets to define the patter, and structures were created by spraying an aqueous solution of glue on the paper surface. The glue-coated paper was then exposed to UV/Vis light for cross-linking to maximize chemical resistance. Examples of microzone arrays and microfluidic devices are demonstrated. μPADs fabricated with scholar glue retained their barriers when used with surfactants, organic solvents, and strong/weak acids and bases unlike common wax-printed barriers. Paper microzones and microfluidic devices were successfully used for colorimetric assays of clinically relevant analytes commonly detected in urinalysis to demonstrate the low background of the barrier material and generally applicability to sensing. The proposed fabrication method is attractive for both its ability to be used with diverse chemistries and the low cost and simplicity of the materials and process. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Stochastic capture zone analysis of an arsenic-contaminated well using the generalized likelihood uncertainty estimator (GLUE) methodology

    NASA Astrophysics Data System (ADS)

    Morse, Brad S.; Pohll, Greg; Huntington, Justin; Rodriguez Castillo, Ramiro

    2003-06-01

    In 1992, Mexican researchers discovered concentrations of arsenic in excess of World Heath Organization (WHO) standards in several municipal wells in the Zimapan Valley of Mexico. This study describes a method to delineate a capture zone for one of the most highly contaminated wells to aid in future well siting. A stochastic approach was used to model the capture zone because of the high level of uncertainty in several input parameters. Two stochastic techniques were performed and compared: "standard" Monte Carlo analysis and the generalized likelihood uncertainty estimator (GLUE) methodology. The GLUE procedure differs from standard Monte Carlo analysis in that it incorporates a goodness of fit (termed a likelihood measure) in evaluating the model. This allows for more information (in this case, head data) to be used in the uncertainty analysis, resulting in smaller prediction uncertainty. Two likelihood measures are tested in this study to determine which are in better agreement with the observed heads. While the standard Monte Carlo approach does not aid in parameter estimation, the GLUE methodology indicates best fit models when hydraulic conductivity is approximately 10-6.5 m/s, with vertically isotropic conditions and large quantities of interbasin flow entering the basin. Probabilistic isochrones (capture zone boundaries) are then presented, and as predicted, the GLUE-derived capture zones are significantly smaller in area than those from the standard Monte Carlo approach.

  14. Preliminary report of a sutureless onlay technique for incisional hernia repair using fibrin glue alone for mesh fixation.

    PubMed

    Stoikes, Nathaniel; Webb, David; Powell, Ben; Voeller, Guy

    2013-11-01

    The Rives repair for ventral/incisional (V/I) hernias involves sublay mesh placement requiring retrorectus dissection and transfascial stitches. Chevrel described a repair by onlaying mesh after a unique primary fascial closure. Although Chevrel fixated mesh to the anterior fascia with sutures, he used fibrin glue for fascial closure reinforcement. We describe an onlay technique with mesh fixated to the anterior fascia solely with fibrin glue without suture fixation. From January 2010 to January 2012, 50 patients underwent a V/I hernia onlay technique with fibrin glue mesh fixation. Records were reviewed for technical details, demographics, mesh characteristics, and postoperative outcomes. Primary fascial closure with interrupted permanent suture was done with or without myofascial advancement flaps. Onlay polypropylene mesh was placed providing 8 cm of overlap. Fibrin glue was applied over the prosthesis and subcutaneous drains were placed. Mean age was 62.4 years. Mean body mass index was 30.1 kg/m(2). Average mesh size was 14.5 cm × 19.1 cm. Mean operative time was 144.4 minutes (range, 38 to 316 minutes). Mean discharge was postoperative Day 2.9 (range, 0 to 15 days). Morbidity included eight seromas, one hematoma, and three wound infections. Seventeen patients required components separation. Mean follow-up was 19.5 months with no recurrences. This is the first series describing fibrin glue alone for mesh fixation for V/I hernia repair. It allows for immediate prosthesis fixation to the anterior fascia. Early results are promising. Potential advantages include less operative time, less technical difficulty, and less long-term pain. A prospective trial is needed to evaluate this approach.

  15. Coronary artery narrowing after aortic root reconstruction with resorcin-formalin glue.

    PubMed

    Martinelli, L; Graffigna, A; Guarnerio, M; Bonmassari, R; Disertori, M

    2000-11-01

    Severe stenosis of right and left main coronary artery ostia developed after aortic root reconstruction with gelatin-resorcin-formol glue for correction of acute type A aortic dissection. Surgical treatment of this condition required grafting of the right and left anterior descending arteries with bilateral mammary arteries on the beating heart.

  16. Comparison of mechanical compressive properties of commercial and autologous fibrin glues for tissue engineering applications.

    PubMed

    Cravens, Matthew G; Behn, Anthony W; Dragoo, Jason L

    2017-11-01

    Fibrin glues are widely used in orthopedic surgery as adhesives and hemostatic agents. We evaluated the compressive properties of selected fibrin glues in order to identify which are appropriate for tissue regeneration applications subject to compression. Uniaxial unconfined compression tests were performed on fibrin gels prepared from commercial and autologous products: (1) Evicel (Ethicon), (2) Tisseel (Baxter), (3) Angel (Arthrex), and (4) ProPlaz (Biorich). Cyclic loads were applied from 0 to 30% strain for 100cycles at 0.5Hz. Following cyclic testing, specimens were subjected to ramp displacement of 1% strain per second to 80% strain. Throughout cyclic loading, Evicel and Tisseel deformed (shortened) less than Angel at all but one time point, and deformed less than ProPlaz at cycles 10 and 20. The dynamic moduli, peak stress, and strain energy were significantly greater in Tisseel than all other groups. Evicel displayed significantly greater dynamic moduli, peak stress, and strain energy than Angel and ProPlaz. Following cyclic testing, Tisseel and Evicel were significantly less deformed than Angel. No specimens exhibited gross failure during ramp loading to 80% strain. Ramp loading trends mirrored those of cyclic loading. The tested commercial glues were significantly more resistant to compression than the autologous products. The compressive properties of Tisseel were approximately twice those of Evicel. All preparations displayed moduli multiple orders of magnitude less than that of native articular cartilage. We conclude that in knee surgeries requiring fibrin glue to undergo compression of daily activity, commercial products are preferable to autologous preparations from platelet-poor plasma, though both will deform significantly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Uranium extraction from TRISO-coated fuel particles using supercritical CO2 containing tri-n-butyl phosphate.

    PubMed

    Zhu, Liyang; Duan, Wuhua; Xu, Jingming; Zhu, Yongjun

    2012-11-30

    High-temperature gas-cooled reactors (HTGRs) are advanced nuclear systems that will receive heavy use in the future. It is important to develop spent nuclear fuel reprocessing technologies for HTGR. A new method for recovering uranium from tristructural-isotropic (TRISO-) coated fuel particles with supercritical CO(2) containing tri-n-butyl phosphate (TBP) as a complexing agent was investigated. TRISO-coated fuel particles from HTGR fuel elements were first crushed to expose UO(2) pellet fuel kernels. The crushed TRISO-coated fuel particles were then treated under O(2) stream at 750°C, resulting in a mixture of U(3)O(8) powder and SiC shells. The conversion of U(3)O(8) into solid uranyl nitrate by its reaction with liquid N(2)O(4) in the presence of a small amount of water was carried out. Complete conversion was achieved after 60 min of reaction at 80°C, whereas the SiC shells were not converted by N(2)O(4). Uranyl nitrate in the converted mixture was extracted with supercritical CO(2) containing TBP. The cumulative extraction efficiency was above 98% after 20 min of online extraction at 50°C and 25 MPa, whereas the SiC shells were not extracted by TBP. The results suggest an attractive strategy for reprocessing spent nuclear fuel from HTGR to minimize the generation of secondary radioactive waste. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. The Knock-Limited Performance of Fuel Blends Containing Spiropentane, Methylenecyclobutane, Di-Tert-Butyl Ether, Methyl Tert-Butyl Ether, and Triptane

    NASA Technical Reports Server (NTRS)

    Meyer, Carl L.

    1946-01-01

    Tests show that at inlet-air temperatures of 250 deg F and 100 deg F the knock-limited performance of the base fuel of blends, leaded with 4 ml TEL per gallon and containing 20 percent spiropentane, was reduced at fuel/air ratios below 0.085. The 20 percent methylenecyclobutane reduced the knock-limited power of the base fuel at fuel/air ratios below 0.112. Di-tert-butyl ether, methyl-tert-butyl ether, and triptane increased the knock-limited power of the base fuel at all fuel/air ratios and at both temperatures.

  19. A direct biocombinatorial strategy toward next generation, mussel-glue inspired saltwater adhesives.

    PubMed

    Wilke, Patrick; Helfricht, Nicolas; Mark, Andreas; Papastavrou, Georg; Faivre, Damien; Börner, Hans G

    2014-09-10

    Biological materials exhibit remarkable, purpose-adapted properties that provide a source of inspiration for designing new materials to meet the requirements of future applications. For instance, marine mussels are able to attach to a broad spectrum of hard surfaces under hostile conditions. Controlling wet-adhesion of synthetic macromolecules by analogue processes promises to strongly impact materials sciences by offering advanced coatings, adhesives, and glues. The de novo design of macromolecules to mimic complex aspects of mussel adhesion still constitutes a challenge. Phage display allows material scientists to design specifically interacting molecules with tailored affinity to material surfaces. Here, we report on the integration of enzymatic processing steps into phage display biopanning to expand the biocombinatorial procedure and enable the direct selection of enzymatically activable peptide adhesion domains. Adsorption isotherms and single molecule force spectroscopy show that those de novo peptides mimic complex aspects of bioadhesion, such as enzymatic activation (by tyrosinase), the switchability from weak to strong binders, and adsorption under hostile saltwater conditions. Furthermore, peptide-poly(ethylene oxide) conjugates are synthesized to generate protective coatings, which possess anti-fouling properties and suppress irreversible interactions with blood-plasma protein cocktails. The extended phage display procedure provides a generic way to non-natural peptide adhesion domains, which not only mimic nature but also improve biological sequence sections extractable from mussel-glue proteins. The de novo peptides manage to combine several tasks in a minimal 12-mer sequence and thus pave the way to overcome major challenges of technical wet glues.

  20. Natura abhorret a vacuo--use of fibrin glue as a filler and sealant in neurosurgical "dead spaces". Technical note.

    PubMed

    Cappabianca, Paolo; Esposito, Felice; Magro, Francesco; Cavallo, Luigi Maria; Solari, Domenico; Stella, Lucio; de Divitiis, Oreste

    2010-05-01

    The objective of this study is to report our experience and illustrate our technique in the use of fibrin glue in the treatment of post-operatory cerebrospinal fluid (CSF) leaks and collections following different neurosurgical procedures. In a 3-year period, 40 subjects underwent endoscopic endonasal approach for different sellar and skull base lesions (three tuberculum sellae meningiomas, six craniopharyngiomas, three Rathke's cleft cysts and 28 pituitary macroadenomas), in which an intraoperative CSF leakage was evident. In such subjects, the fibrin glue was used as a first step of the final phase of the procedure-i.e. the reconstruction of the skull base defect-followed by the other materials employed. Furthermore, ten other patients, who had undergone transsphenoidal (four cases), spinal (two cases), posterior fossa (three cases) and transcortical intraventricular tumour removal (one case) neurosurgical procedures and developed CSF leaks or collections, were conservatively treated by single or repeated in situ injections of "modified" fibrin glue under local anaesthesia according to different described techniques. In total, 50 patients constitute the clinical material of the present study. In the cases where the fibrin glue was used during the reconstruction phase of the procedure (40 cases), the glue was injected inside the tumour cavity to fill the dead space left by the removal of the lesion. In case of post-operative CSF leak or CSF fluid collection (ten cases), after discarding 50-80% of the thrombin solution to obtain prevalence of the product's adhesive properties, fibrin glue was injected directly in the path of the CSF leak or into the collection cavity after aspiration of the collection's content. This was performed with the provided application system or through lumbar or Tuohy needles. Applications were repeated every 48 h until the disappearance of the leak. In all the treated cases, the disappearance of CSF leaks or collections was obtained with

  1. Methyl tert-butyl ether (MTBE)

    Integrated Risk Information System (IRIS)

    Methyl tert - butyl ether ( MTBE ) ; CASRN 1634 - 04 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments f

  2. Disastrous Portal Vein Embolization Turned into a Successful Intervention

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dobrocky, Tomas, E-mail: tomas.dobrocky@insel.ch; Kettenbach, Joachim, E-mail: joachim.kettenbach@stpoelten.lknoe.at; Lopez-Benitez, Ruben, E-mail: Ruben.lopez@insel.ch

    Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloonmore » catheter, inflating the balloon, and pulling the plug into the main right portal vein.« less

  3. 40 CFR 721.1579 - 1,2,4-Benzenetricarboxylic acid, tris [4-(ethenyloxy) butyl] ester.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... [4-(ethenyloxy) butyl] ester. 721.1579 Section 721.1579 Protection of Environment ENVIRONMENTAL...-(ethenyloxy) butyl] ester. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as 1,2,4-benzenetricarboxylic acid, tris [4-(ethenyloxy) butyl] ester (PMN P...

  4. 40 CFR 721.1579 - 1,2,4-Benzenetricarboxylic acid, tris [4-(ethenyloxy) butyl] ester.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... [4-(ethenyloxy) butyl] ester. 721.1579 Section 721.1579 Protection of Environment ENVIRONMENTAL...-(ethenyloxy) butyl] ester. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as 1,2,4-benzenetricarboxylic acid, tris [4-(ethenyloxy) butyl] ester (PMN P...

  5. Molecular Modeling and docking of Wheat Hydroquinone Glucosyl transferase by using Hydroquinone, Phenyl phosphorodiamate and n-(n butyl) Phosphorothiocic Triamide as Inhibitors

    PubMed Central

    Huma, Tayyaba; Maryam, Arooma; qamar, Tahir ul

    2014-01-01

    In agriculture high urease activity during urea fertilization causes substantial environmental and economical problems by releasing abnormally large amount of ammonia into the atmosphere which leads to plant damage as well as ammonia toxicity. All over the world, urea is the most widely applied nitrogen fertilizer. Due to the action of enzyme urease; urea nitrogen is lost as volatile ammonia. For efficient use of nitrogen fertilizer, urease inhibitor along with the urea fertilizer is one of the best promising strategies. Urease inhibitors also provide an insight in understanding the mechanism of enzyme catalyzed reaction, the role of various amino acids in catalytic activity present at the active site of enzyme and the importance of nickel to this metallo enzyme. By keeping it in view, the present study was designed to dock three urease inhibitors namely Hydroquinone (HQ), Phenyl Phosphorodiamate (PPD) and N-(n-butyl) Phosphorothiocic triamide (NBPT) against Hydroquinone glucosyltransferase using molecular docking approach. The 3D structure of Hydroquinone glucosyltransferase was predicted using homology modeling approach and quality of the structure was assured using Ramachandran plot. This study revealed important interactions among the urease inhibitors and Hydroquinone glucosyltransferase. Thus, it can be inferred that these inhibitors may serve as future anti toxic constituent against plant toxins. PMID:24748751

  6. Molecular Modeling and docking of Wheat Hydroquinone Glucosyl transferase by using Hydroquinone, Phenyl phosphorodiamate and n-(n butyl) Phosphorothiocic Triamide as Inhibitors.

    PubMed

    Huma, Tayyaba; Maryam, Arooma; Qamar, Tahir Ul

    2014-01-01

    In agriculture high urease activity during urea fertilization causes substantial environmental and economical problems by releasing abnormally large amount of ammonia into the atmosphere which leads to plant damage as well as ammonia toxicity. All over the world, urea is the most widely applied nitrogen fertilizer. Due to the action of enzyme urease; urea nitrogen is lost as volatile ammonia. For efficient use of nitrogen fertilizer, urease inhibitor along with the urea fertilizer is one of the best promising strategies. Urease inhibitors also provide an insight in understanding the mechanism of enzyme catalyzed reaction, the role of various amino acids in catalytic activity present at the active site of enzyme and the importance of nickel to this metallo enzyme. By keeping it in view, the present study was designed to dock three urease inhibitors namely Hydroquinone (HQ), Phenyl Phosphorodiamate (PPD) and N-(n-butyl) Phosphorothiocic triamide (NBPT) against Hydroquinone glucosyltransferase using molecular docking approach. The 3D structure of Hydroquinone glucosyltransferase was predicted using homology modeling approach and quality of the structure was assured using Ramachandran plot. This study revealed important interactions among the urease inhibitors and Hydroquinone glucosyltransferase. Thus, it can be inferred that these inhibitors may serve as future anti toxic constituent against plant toxins.

  7. Reduction of bone resorption by the application of fibrin glue in the reconstruction of the alveolar cleft.

    PubMed

    Segura-Castillo, José L; Aguirre-Camacho, Humberto; González-Ojeda, Alejandro; Michel-Perez, Jorge

    2005-01-01

    A major complication in 30% to 75% of cases of surgical treatment of alveolar cleft is resorption of the bone graft. A treatment alternative is the application of fibrin glue, which has the capacity to favor the integration of the graft. The main objective of the study was to evaluate if the use of the fibrin glue reduces bone resorption when it is applied locally. The authors designed a randomized clinical trial. Patients were divided into two groups: group 1, fibrin glue; and group 2, control. Pre- and postoperative graft volume, bone density, bone quality (Lekholm and Zarb, and Norton and Gamble classifications), and postoperative complications were evaluated. The follow-up for all patients was 3 months after discharge. Twenty-seven patients were surgically treated, 13 in group 1 and 14 in group 2. Group 1 had increased graft volume compared with group 2 (64.32 cm v 21.70 cm; P < 0.0001). Bone density was higher in group 1 than in group 2 (396.57 v 245.68; P > 0.076). Bone quality was type 1, 2 and 3 and 4 in group 1. Resorption in group 2 was 62.26%; in group 1, it was 29.72% (P > 0.081). The observed complications were infection and dehiscence of sutures (P > 0.537). The authors conclude that the fibrin glue significantly diminishes bone resorption, allowing improved graft integration and quality.

  8. Comparison of Fibrin Glue and Sutures for Conjunctival Wound Closure in Strabismus Surgery

    PubMed Central

    Lee, Jae Hyung

    2011-01-01

    Purpose To evaluate and compare the efficacy and tolerance of fibrin glue and sutures for closing conjunctival wounds in strabismus surgery. Methods In a prospective trial, we performed strabismus surgery using limbal incisions. Conjunctival wounds were closed with fibrin glue in 20 eyes of 20 patients (fibrin group) and 8-0 polyglactin suture in 20 eyes of 20 patients (suture group). Postoperative pain, tearing, and inflammation were compared at 1 day, 1 week, 3 weeks, and 6 weeks after surgery. Conjunctival incision healing was also investigated. Results One day and one week post-operatively, pain and tearing scores were lower in the fibrin group (p = 0.000, respectively). Mean surgery time was significantly shorter in the fibrin (48 ± 5 minutes) than the suture group (63 ± 7 minutes) (p = 0.000). Inflammation was significantly more severe in the suture group until 3 weeks postoperative (p = 0.000, respectively), but conjunctival healing did not differ between the groups. Hyperemia appeared more prominent in the fibrin group 3 and 6 weeks after surgery (p = 0.087 and 0.000, respectively). Two eyes in the fibrin group showed conjunctival gaps of more than 2 mm, which closed spontaneously by three weeks after surgery. No allergic reactions or infections developed. Conclusions Fibrin glue proved to be as effective as sutures in closing conjunctival wounds. It provides more comfortable early postoperative courses and might be considered as an alternative to sutures in strabismus surgery. PMID:21655043

  9. 40 CFR 721.4105 - Bicyclo[2.2.1]hept-2-ene, 5-butyl-.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Bicyclo[2.2.1]hept-2-ene, 5-butyl... Substances § 721.4105 Bicyclo[2.2.1]hept-2-ene, 5-butyl-. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as Bicyclo[2.2.1]hept-2-ene, 5-butyl- (PMN P...

  10. 40 CFR 721.4105 - Bicyclo[2.2.1]hept-2-ene, 5-butyl-.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Bicyclo[2.2.1]hept-2-ene, 5-butyl... Substances § 721.4105 Bicyclo[2.2.1]hept-2-ene, 5-butyl-. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as Bicyclo[2.2.1]hept-2-ene, 5-butyl- (PMN P...

  11. Synthetic phenolic antioxidants, including butylated hydroxytoluene (BHT), in resin-based dental sealants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Wei; Kannan, Pranav; Xue, Jingchuan

    Resin-based dental sealants (also referred to as pit-and-fissure sealants) have been studied for their contribution to bisphenol A (BPA) exposure in children. Nevertheless, little attention has been paid to the occurrence of other potentially toxic chemicals in dental sealants. In this study, the occurrence of six synthetic phenolic antioxidants (SPAs), including 2,6-di-tert-butyl-4-hydroxytoluene (BHT), 2,6-di-tert-butyl-4-(hydroxyethyl)phenol (BHT-OH), 3,5-di-tert-butyl-4-hydroxy-benzaldehyde (BHT-CHO), 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q), 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) and 2-tert-butyl-4-methoxyphenol (BHA), was examined in 63 dental sealant products purchased from the U.S. market. BHT was found in all dental sealants at median and maximum concentrations of 56.8 and 1020 µg/g, respectively. The metabolites of BHT andmore » BHA were detected in 39–67% of samples, at concentration ranges of« less

  12. Thermally Switchable Thin Films of an ABC Triblock Copolymer of Poly(n-butyl methacrylate)-poly(methyl methacrylate)-poly(2-fluoroethyl methacrylate)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Shanju; Liu, Zhan; Bucknall, David G.

    2011-01-01

    The thermo-responsive behavior of polymer films consisting of novel linear triblock copolymers of poly(n-butyl methacrylate)-poly(methyl methacrylate)-poly(2-fluoroethyl methacrylate) (PnBuMA-PMMA-P2FEMA) are reported using differential scanning calorimetry (DSC), atomic forcing microscopy (AFM), X-ray photoelectron spectroscopy (XPS) and contacting angle (CA) measurements. The surface morphology, wettability and chemical structure of thin films of these triblock copolymers on silicon wafers as a function of temperature have been investigated. It has been shown that the wettability of the films is thermally switchable. Detailed structural analysis shows that thermo-responsive surface composition changes are produced. The underlying mechanism of the thermoresponsive behavior is discussed.

  13. Effects of In Utero Exposure to Di-n-Butyl Phthalate on Testicular Development in Rat

    PubMed Central

    Ma, Tan; Yin, Xiaoqin; Han, Ruitong; Ding, Jie; Zhang, Huan; Han, Xiaodong

    2017-01-01

    Humans are inevitably exposed to ubiquitous phthalate esters (PAEs). In utero exposure to di-n-butyl phthalate (DBP) induces abnormal development of the testis and reproductive tract in male offspring, which correspond closely with the human condition of testicular dysgenesis syndrome (TDS)-like syndrome. However, the underlying mechanisms have not been elucidated in detail. In this study, pregnant rats were orally exposed to either corn oil (controls) or DBP at three different doses by gavage during Gestational Days 12.5–21.5. Pathological examinations were performed for toxicity evaluation. Proliferation and apoptosis related proteins (ras related dexamethasone induced 1 (Rasd1), mitogen-activated protein kinase kinases1/2 (MEK1/2), Bcl-2, and Bax) were measured for mechanisms exploration. The results showed that different doses of DBP caused male developmental and reproductive toxicity in rats, including the decrease of anogenital distance (AGD), the histological damage of testis, and apoptosis of seminiferous tubule cells. Our data suggested that DBP played chronic and continuous toxic roles on male reproductive system by disrupting expression of Rasd1 and MEK1/2 as well as Bcl-2/Bax ratio. Further research is warranted. PMID:29064414

  14. Poly(ester urea)-Based Adhesives: Improved Deployment and Adhesion by Incorporation of Poly(propylene glycol) Segments.

    PubMed

    Zhou, Jinjun; Bhagat, Vrushali; Becker, Matthew L

    2016-12-14

    The adhesive nature of mussels arises from the catechol moiety in the 3,4-dihydroxyphenylalanine (DOPA) amino acid, one of the many proteins that contribute to the unique adhesion properties of mussels. Inspired by these properties, many biomimetic adhesives have been developed over the past few years in an attempt to replace adhesives such as fibrin, cyanoacrylate, and epoxy glues. In the present work, we synthesized ethanol soluble but water insoluble catechol functionalized poly(ester urea) random copolymers that help facilitate delivery and adhesion in wet environments. Poly(propylene glycol) units incorporated into the polymer backbone impart ethanol solubility to these polymers, making them clinically relevant. A catechol to cross-linker ratio of 10:1 with a curing time of 4 h exceeded the performance of commercial fibrin glue (4.8 ± 1.4 kPa) with adhesion strength of 10.6 ± 2.1 kPa. These adhesion strengths are significant with the consideration that the adhesion studies were performed under wet conditions.

  15. NTP-CERHR Monograph on the Potential Human Reproductive and Developmental Effects of Di-n-Butyl Phthalate (DBP).

    PubMed

    2003-04-01

    TThe National Toxicology Program (NTP) Center for the Evaluation of Risks to Human Reproduction (CERHR) conducted an evaluation of the potential for di-n-butyl phthalate (DBP) to cause adverse effects on reproduction and development in humans. DBP is one of 7 phthalate chemicals evaluated by the NTP CERHR Phthalates Expert Panel. These phthalates were selected for evaluation because of high production volume, extent of human exposures, use in children's products, and/or published evidence of reproductive or developmental toxicity. Unlike many phthalates, DBP is not currently used as a plasticizer in polyvinyl chloride plastics. DBP is a component of latex adhesives and is used in cosmetics and other personal care products, as a plasticizer in cellulose plastics, and as a solvent for dyes. The results of this evaluation on DBP are published in a NTP-CERHR monograph which includes: 1) the NTP Brief, 2) the Expert Panel Report on the Reproductive and Developmental Toxicity of Di-n-Butyl Phthalate, and 3) public comments received on the Expert Panel Report. As stated in the NTP Brief, the NTP reached the following conclusions regarding the possible effects of exposure to DBP on human development and reproduction. First, although DBP could possibly affect human reproduction and development if exposures are sufficiently high, the NTP concludes that there is negligible concern for reproductive toxicity in exposed adults. Second, the NTP concludes that there is minimal concern for developmental effects when pregnant women are exposed to DBP levels estimated by the panel (2-10 mug/kg body weight/day). There is no direct evidence that exposure of people to DBP adversely affects reproduction or development, but studies reviewed by the expert panel show that oral exposure to high doses of DBP (>/=100 mg/kg body weight/day) may adversely affect the prenatal and early postnatal development in rodents. Finally, based on exposure estimates in women of reproductive age, the NTP

  16. Shear lag sutures: Improved suture repair through the use of adhesives

    PubMed Central

    Linderman, Stephen W.; Kormpakis, Ioannis; Gelberman, Richard H.; Birman, Victor; Wegst, Ulrike G. K.; Genin, Guy M.; Thomopoulos, Stavros

    2015-01-01

    Suture materials and surgical knot tying techniques have improved dramatically since their first use over five millennia ago. However, the approach remains limited by the ability of the suture to transfer load to tissue at suture anchor points. Here, we predict that adhesive-coated sutures can improve mechanical load transfer beyond the range of performance of existing suture methods, thereby strengthening repairs and decreasing the risk of failure. The mechanical properties of suitable adhesives were identified using a shear lag model. Examination of the design space for an optimal adhesive demonstrated requirements for strong adhesion and low stiffness to maximize the strength of the adhesive-coated suture repair construct. To experimentally assess the model, we evaluated single strands of sutures coated with highly flexible cyanoacrylates (Loctite 4903 and 4902), cyanoacrylate (Loctite QuickTite Instant Adhesive Gel), rubber cement, rubber/gasket adhesive (1300 Scotch-Weld Neoprene High Performance Rubber & Gasket Adhesive), an albumin-glutaraldehyde adhesive (BioGlue), or poly(dopamine). As a clinically relevant proof-of-concept, cyanoacrylate-coated sutures were then used to perform a clinically relevant flexor digitorum tendon repair in cadaver tissue. The repair performed with adhesive-coated suture had significantly higher strength compared to the standard repair without adhesive. Notably, cyanoacrylate provides strong adhesion with high stiffness and brittle behavior, and is therefore not an ideal adhesive for enhancing suture repair. Nevertheless, the improvement in repair properties in a clinically relevant setting, even using a non-ideal adhesive, demonstrates the potential for the proposed approach to improve outcomes for treatments requiring suture fixation. Further study is necessary to develop a strongly adherent, compliant adhesive within the optimal design space described by the model. PMID:26022966

  17. Structural elucidation of 4-(cystein-S-yl)butyl glucosinolate from the leaves of Eruca sativa.

    PubMed

    Kim, Sun-Ju; Kawaharada, Chiami; Jin, Shigeki; Hashimoto, Makoto; Ishii, Gensho; Yamauchi, Hiroaki

    2007-01-01

    The structurally unique glucosinolate (GSL), 4-(cystein-S-yl)butyl GSL, was identified in the leaves of hydroponically-grown rocket salad (Eruca sativa Mill.). Its electrospray ionization mass spectrometry (ESI-MS)/MS spectrum indicated that this unusual GSL had a molecular weight of 414 as a desulfo (DS)-GSL, and a molecular formula of C(14)H(25)N(2)O(8)S(2) based on its negative ion matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) spectrum. For further confirmation, the 4-(cystein-S-yl)butyl DS-GSL was prepared with authentic L-Ser and purified dimeric 4-mercaptobutyl DS-GSL, and its chemical structure then confirmed by ESI-MS/MS data. It is named "glucorucolamine" as a trivial name from its ammonia sensitivity. This unique GSL was found to the greatest extent when rocket salad was grown in a 100% NH4+-N nutrient solution. Despite it clearly seems to reduce the detoxification of excess NH4+ in the leaves of rocket salad, present knowledge about the unique GSL is still far from being sufficient.

  18. 40 CFR 721.6920 - Butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Butyl acrylate, polymer with... NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.6920 Butyl... butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane...

  19. Cholesterol-PEG comodified poly (N-butyl) cyanoacrylate nanoparticles for brain delivery: in vitro and in vivo evaluations.

    PubMed

    Hu, Xiao; Yang, Feifei; Liao, Yonghong; Li, Lin; Zhang, Lan

    2017-11-01

    This study investigated cholesterol-polyethylene glycol (PEG) comodified poly (ethyleneglycol)-poly (lactide) nanoparticles (CLS-PEG NPs) as a novel, biodegradable brain drug delivery system and included an evaluation of its in vitro and in vivo properties. To this end, coumarin-6 (C6), a fluorescent probe, was encapsulated into CLS-PEG NPs by an emulsion polymerization method. We reported that the use of CLS-PEG NPs led to a sustained drug release in vitro. Additionally, cell viability experiments confirmed their safety. The uptake and transport of CLS-PEG NPs, by bEnd.3 cells (an immortalized mouse brain endothelial cell line), was significantly higher than that of a control C6 solution. An investigation of the uptake mechanisms of different NP formulations demonstrated that cholesterol modifications may be the primary way to improve the efficiency of cellular uptake, wherein macropinocytosis may be the most important endocytic pathway in this process. An investigation of the transport mechanisms of CLS-PEG NPs also implicated macropinocytosis, energy and cholesterol in bEnd.3 cells lines. Following an intravenous (IV) administration to rats, pharmacokinetic experiments indicated that C6-loaded CLS-PEG NPs achieved sustained release for up to 12 h. In addition, IV delivery of CLS-PEG NPs appeared to significantly improve the ability of C6 to pass through the blood-brain barrier: the concentration of C6 found in the brain increased nearly 14.2-fold when C6 CLS-PEG NPs were used rather than a C6 solution. These in vitro and in vivo results strongly suggest that CLS-PEG NPs are a promising drug delivery system for targeting the brain, with low toxicity.

  20. Reactivity of lithium n-butyl amidinates towards group 14 metal(II) chlorides providing series of hetero- and homoleptic tetrylenes.

    PubMed

    Chlupatý, Tomáš; Padělková, Zdeňka; Lyčka, Antonín; Brus, Jiří; Růžička, Aleš

    2012-04-28

    The new class of homo- and heteroleptic n-butyl-N,N'-disubstituted amidinato group 14 metal(II) complexes were prepared by salt elimination from starting lithium amidinates and metal(II) chlorides both in stoichiometric ratio 2:1 and 1:1, respectively. The target amidinates contain less bulky isopropyl or cyclohexyl as well as a sterically demanding aromatic substituent. Desired 1:1 Pb(II) complexes are not accessible by the described procedure. Ligand transfer from Pb to Sn is taking place if homoleptic Pb(II) compounds are reacted with SnCl(2). Prepared tetrylenes were characterized by (1)H, (13)C, (119)Sn and (207)Pb NMR spectroscopy in C(6)D(6) or THF-d(8). X-Ray diffraction studies of one heteroleptic Ge(II) monomeric where the coordination polyhedron of the three coordinated germanium atoms is a trigonal pyramid, two different dimeric structures of heteroleptic Sn(II) complexes, one amidine hydroiodide byproduct and the oxidation product of the heteroleptic chloro Sn(II) amidinate as a tetranuclear species with two Sn(IV) and two Sn(II) atoms in central Sn(2)O(2) planar ring were performed on appropriate single crystals. The dimer of one of the heteroleptic stannylenes reveals a new type of monomeric units connection, weak Sn-Cl contact and an interaction of the tin atom with delocalized N-C(C)-N system of the amidinato ligand of the second molecule. This journal is © The Royal Society of Chemistry 2012

  1. Thermodynamic Equilibrium Solubility of Diethanolamine – N-Butyl-1-Methylpyrrolidinium Dicyanamide [DEABMPYRR DCA] Mixtures for Carbon Dioxide Capture

    NASA Astrophysics Data System (ADS)

    Salleh, R. M.; Jamaludin, S. N.

    2018-05-01

    Solubility data of carbon dioxide (CO2) in aqueous Diethanolamine (DEA) blended with pyrrolidinium-based ionic liquid: N-Butyl-1-Methylpyrrolidinium Dıcyanamıde [Bmpyrr][DCA] are presented at various temperatures (313.15K-333.15K) and pressure up to about 700 psi. The concentration of [Bmpyrr][DCA] ranges from 0-10wt% and 30-40wt% for DEA. The solubility of CO2 was evaluated by measuring the pressure drop in high pressure stirred absorption cell reactor. The CO2 loading in all studied mixtures increases with an increase in CO2 partial pressure and decreases with temperature. It was also found that the CO2 loading capacity decrease as the concentration of [Bmpyrr][DCA] increases. The experimental data were correlated as a function of temperature and CO2 partial pressure to predict the solubility of CO2 in the mixtures. It was found that the model predicted results in a good agreement with experimental value.

  2. 21 CFR 172.270 - Sulfated butyl oleate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... edible vegetable oil using 1-butanol. Following sulfation, the reaction mixture is washed with water and neutralized with aqueous sodium or potassium hydroxide. Prior to sulfation, the butyl oleate reaction mixture...

  3. Study of the nature of the confinement in the GlueX experiment

    DOE PAGES

    Somov, S.; Berdnikov, Vladmir; Tolstukhin, Ivan; ...

    2015-11-03

    Confinement is a fundamental property of quantum chromodynamics (QCD) associated with the unique role of the gluonic field responsible for binding quarks in hadrons. Understanding the role of gluons in the confinement of quarks is one of the most tantalizing topics in modern particle physics to be explored. The new experiment GlueX has been recently constructed at Jefferson Lab. The experiment was designed to search for hybrid mesons with exotic quantum numbers using a beam of linearly polarized photons incident on a liquid hydrogen target. The spectrum of these states and their mass splitting from normal mesons may yield informationmore » on confinement. In addition, these observations in combination with detailed chromodynamics calculations such as on the Lattice can provide important tests for our understanding of the role of gluons. The production of exotic mesons is expected to be enhanced in p interactions, where the experimental data is very limited. We present the description of the GlueX detector, beam line, and first results of the commissioning with photon beam.« less

  4. The Research of Improving the Particleboard Glue Dosing Process Based on TRIZ Analysis

    NASA Astrophysics Data System (ADS)

    Yu, Huiling; Fan, Delin; Zhang, Yizhuo

    This research creates a design methodology by synthesizing the Theory of Inventive Problem Solving (TRIZ) and cascade control based on Smith predictor. The particleboard glue supplying and dosing system case study defines the problem and the solution using the methodology proposed in the paper. Status difference existing in the gluing dosing process of particleboard production usually causes gluing volume inaccurately. In order to solve the problem above, we applied the TRIZ technical contradiction and inventive principle to improve the key process of particleboard production. The improving method mapped inaccurate problem to TRIZ technical contradiction, the prior action proposed Smith predictor as the control algorithm in the glue dosing system. This research examines the usefulness of a TRIZ based problem-solving process designed to improve the problem-solving ability of users in addressing difficult or reoccurring problems and also testify TRIZ is practicality and validity. Several suggestions are presented on how to approach this problem.

  5. Percutaneous sclerotherapy of sialoceles after parotidectomy with fibrin glue, OK-432, and bleomycin.

    PubMed

    Chen, Wei-liang; Zhang, Li-ping; Huang, Zhi-quan; Zhou, Bin

    2013-12-01

    We evaluated the curative effect of fibrin glue combined with OK-432 (streptococcal pyrogenic exotoxin A, Picibanil™) and bleomycin on 9 patients with sialoceles after parotidectomy. The primary lesions included pleomorphic adenomas in 6 cases and Warthin's tumours in 3 cases. After a sialocele had been diagnosed each patient had repeated aspirations and pressure dressings for 3-4 weeks, but these treatments failed. The patients were then treated with percutaneous sclerotherapy with the injection of fibrin glue 8-10 ml combined with OK-432 5 mg and bleomycin 15 mg. All the sialoceles disappeared completely after a single procedure in 2-3 weeks. The patients have been followed up for more than 6 months with no evidence of recurrent sialocele or injury to the facial nerve related to sclerotherapy. This simple, safe technique can be successfully used to treat sialoceles after parotidectomy. Copyright © 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Generalized Likelihood Uncertainty Estimation (GLUE) methodology for optimization of extraction in natural products.

    PubMed

    Maulidiani; Rudiyanto; Abas, Faridah; Ismail, Intan Safinar; Lajis, Nordin H

    2018-06-01

    Optimization process is an important aspect in the natural product extractions. Herein, an alternative approach is proposed for the optimization in extraction, namely, the Generalized Likelihood Uncertainty Estimation (GLUE). The approach combines the Latin hypercube sampling, the feasible range of independent variables, the Monte Carlo simulation, and the threshold criteria of response variables. The GLUE method is tested in three different techniques including the ultrasound, the microwave, and the supercritical CO 2 assisted extractions utilizing the data from previously published reports. The study found that this method can: provide more information on the combined effects of the independent variables on the response variables in the dotty plots; deal with unlimited number of independent and response variables; consider combined multiple threshold criteria, which is subjective depending on the target of the investigation for response variables; and provide a range of values with their distribution for the optimization. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. The reclaiming of butyl rubber and in-situ compatibilization of thermoplastic elastomer by power ultrasound

    NASA Astrophysics Data System (ADS)

    Feng, Wenlai

    This is a study of the continuous ultrasound aided extrusion process for the in-situ compatibilization of isotactic polypropylene (iPP)/ethylene-propylene diene rubber (EPDM) thermoplastic elastomer (TPE) using a newly developed ultrasonic treatment reactor. The rheological, mechanical properties and morphology of the TPE with and without ultrasonic treatment were studied. In-situ compatibilization in the ultrasonically treated blends was observed as evident by their more stable morphology after annealing, improved mechanical properties and IR spectra. The obtained results indicated that ultrasonic treatment induced the thermo-mechanical degradations and led to the possibility of enhanced molecular transport and chemical reactions at the interfaces. Processing conditions were established for enhanced in situ compatibilization of the PP/EPDM TPE. The ultrasonic treatments of butyl rubber gum and ultrasonic devulcanization of butyl rubber, tire-curing bladder during extrusion using a grooved barrel ultrasonic reactor were carried out. The ultrasonic treatment of gum caused degradation of the polymer main chain leading to lower molecular weight, broader molecular weight distribution, less unsaturation and changes in physical properties. The devulcanization of butyl rubber was successfully accomplished only at severe conditions of ultrasonic treatment. The mechanical properties of vulcanizates prepared from devulcanized butyl rubber are comparable to that of the virgin vulcanizate. The molecular characterization of sol fraction of devulcanized butyl rubber showed the devulcanization and degradation of butyl rubber occurred simultaneously. 1H NMR transverse relaxation was also used to study butyl rubber gum before and after ultrasonic treatment, and ultrasonically devulcanized unfilled butyl rubber. The T2 relaxation decays were successfully described using a two-component model. The recyclability of tire-curing bladder was also investigated. Gel fraction, crosslink

  8. Intraoperative use of fibrin glue dyed with methylene blue in surgery for branchial cleft anomalies.

    PubMed

    Piccioni, Michela; Bottazzoli, Marco; Nassif, Nader; Stefini, Stefania; Nicolai, Piero

    2016-09-01

    We present a new method of optimizing the results of surgery for branchial cleft anomalies based on the intraoperative injection of fibrin glue combined with methylene blue dye. Retrospective single-center cohort study. The method was applied in 17 patients suffering from branchial anomalies. Six (35.29%) had a preauricular lesion; three (17.65%) had lesions derived from the first arch/pouch/groove (type I), four (23.53%) had lesions derived from the first (type II), one (5.88%) had lesions derived from the second, one (5.88%) had lesions derived from the third, and two (11.76%) had lesions derived from the fourth. The median and mean age at surgery were 10 and 10.6 years, respectively. All patients were followed by periodic clinical and ultrasonographic examination. The combination of fibrin glue with methylene blue facilitated the correct assessment of the extension of the lesions and their intraoperative manipulation. After a mean follow-up of 47.8 months, all patients were free of disease. Intraoperative injection of branchial fistulae and cysts by a mixture of fibrin glue and methylene blue is an effective, easy, and safe tool to track lesions and achieve radical resection. The technique requires a definitive validation on a large cohort with adequate stratification of patients. 4 Laryngoscope, 126:2147-2150, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  9. 21 CFR 172.270 - Sulfated butyl oleate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... transesterification of an edible vegetable oil using 1-butanol. Following sulfation, the reaction mixture is washed... oleate reaction mixture meets the following specifications: (1) Not less than 90 percent butyl oleate. (2...

  10. Atomic layer deposition of zirconium silicate films using zirconium tetrachloride and tetra-n-butyl orthosilicate

    NASA Astrophysics Data System (ADS)

    Kim, Won-Kyu; Kang, Sang-Woo; Rhee, Shi-Woo; Lee, Nae-In; Lee, Jong-Ho; Kang, Ho-Kyu

    2002-11-01

    Atomic layer chemical vapor deposition of zirconium silicate films with a precursor combination of ZrCl4 and tetra-n-butyl orthosilicate (TBOS) was studied for high dielectric gate insulators. The effect of deposition conditions, such as deposition temperature, pulse time for purge and precursor injection on the deposition rate per cycle, and composition of the film were studied. At 400 °C, the growth rate saturated to 1.35 Å/cycle above 500 sccm of the argon purge flow rate. The growth rate, composition ratio ((Zr/Zr+Si)), and impurity contents (carbon and chlorine) saturated with the increase of the injection time of ZrCl4 and TBOS and decreased with the increased deposition temperature from 300 to 500 °C. The growth rate, composition ratio, carbon, and chlorine contents of the Zr silicate thin films deposited at 500 °C were 1.05 Å/cycle, 0.23, 1.1 at. %, and 2.1 at. %, respectively. It appeared that by using only zirconium chloride and silicon alkoxide sources, the content of carbon and chlorine impurities could not be lowered below 1%. It was also found that the incorporation rate of metal from halide source was lower than alkoxide source.

  11. The GlueX central drift chamber: Design and performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Haarlem, Y; Barbosa, F; Dey, B

    2010-10-01

    Tests and studies concerning the design and performance of the GlueX Central Drift Chamber (CDC) are presented. A full-scale prototype was built to test and steer the mechanical and electronic design. Small scale prototypes were constructed to test for sagging and to do timing and resolution studies of the detector. These studies were used to choose the gas mixture and to program a Monte Carlo simulation that can predict the detector response in an external magnetic field. Particle identification and charge division possibilities were also investigated.

  12. In Utero Exposure to Di( n-butyl)phthalate Induces Morphological and Biochemical Changes in Rats Postpuberty.

    PubMed

    Okayama, Yuya; Wakui, Shin; Wempe, Michael F; Sugiyama, Mitsuru; Motohashi, Masaya; Mutou, Tomoko; Takahashi, Hiroyuki; Kume, Eisuke; Ikegami, Hiroshi

    2017-06-01

    Pregnant Sprague-Dawley rats were orally administered di( n-butyl)phthalate (DBP; 100 mg/kg/day) on gestation days (GD) 12 to 21. We investigated the male offspring and probed morphological alterations in Sertoli cells at 7, 9, 14, and 17 weeks of age. Parameters assessed in this study included offspring number, sex ratios, body weights, testis weights, seminiferous tubule (ST) profile numbers and diameters, number of vimentin-labeled Sertoli cells, and both testosterone and follicle-stimulating hormone (FSH) levels. Testicular weight/body weight ratios and the numbers and diameters of ST in maximum transverse testicular sections were statistically similar at weeks 7 and 9; however, at weeks 14 and 17, they were statistically different and displayed higher BrdU-positive Sertoli cells/Sertoli cell ratios in the DBP treatment group. Noteworthily, the serum FSH levels were higher and testicular testosterone levels were lower in the DBP treatment group. To our knowledge, the present study is the first to report that in utero DBP exposure significantly increased Sertoli cell numbers and their cellular proliferation from postpuberty to adulthood, with a significant decrease in testicular testosterone and an increase in FSH.

  13. Assessment of Synthetic Glue for Mesh Attachment in Laparoscopic Sacrocolpopexy: A Prospective Multicenter Pilot Study.

    PubMed

    Lamblin, Gery; Dubernard, Gil; de Saint Hilaire, Pierre; Jacquot, Franck; Chabert, Philippe; Chene, Gautier; Golfier, François

    2017-01-01

    To assess the anatomic efficacy and safety of synthetic glue to fix prosthetic material in laparoscopic sacrocolpopexy. A 1-year follow-up in a prospective multicenter pilot study between November 2013 and November 2014 (Canadian Task Force Classification II-2). An academic urogynecology research hospital. Seventy consecutive patients with Pelvic Organ Prolapse Quantification stage ≥3 anterior and/or medial prolapse underwent laparoscopic sacrocolpopexy. All women underwent laparoscopic sacrocolpopexy with the same standardized technique using a synthetic surgical glue to fix anterior and posterior meshes. Patients were followed up at 1 month and 1 year, with anatomic and functional assessment (Pelvic Floor Distress Inventory-20, Pelvic Floor Impact Questionnaire-7, and Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire-12). Anatomic success was defined as 1-year Pelvic Organ Prolapse Quantification stage ≤1. Sixty-six patients were included; the mean age was 56.7 ± 1.2 years. The mean operative time was 145 ± 5 minutes. The mean glue fixation time was less than 2 minutes for both anterior and posterior meshes. The 1-year anatomic success rate was 87.5% in the anterior compartment (Ba at -2.3 cm, p < .0001) and 95.3% in the medial compartment (point C at -6.1 cm, p < .0001). There were no intra- or postoperative complications and no cases of mesh exposure; 5 cases of mesh shrinkage (7.8%) were observed at 1 year. The postoperative urinary stress incontinence rate was 29.7% at 1 year. Eight patients (12.1%) underwent revision surgery with transobturator tape. All quality of life scores showed significant improvement (p < .0001) at 1 year. Synthetic glue attachment of prosthetic material in laparoscopic sacrocolpopexy proved straightforward, safe, time-saving, and effective at 1 year. Prospective randomized studies will be needed to confirm the long-term benefit. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights

  14. Uncertainty and sensitivity assessments of an agricultural-hydrological model (RZWQM2) using the GLUE method

    NASA Astrophysics Data System (ADS)

    Sun, Mei; Zhang, Xiaolin; Huo, Zailin; Feng, Shaoyuan; Huang, Guanhua; Mao, Xiaomin

    2016-03-01

    Quantitatively ascertaining and analyzing the effects of model uncertainty on model reliability is a focal point for agricultural-hydrological models due to more uncertainties of inputs and processes. In this study, the generalized likelihood uncertainty estimation (GLUE) method with Latin hypercube sampling (LHS) was used to evaluate the uncertainty of the RZWQM-DSSAT (RZWQM2) model outputs responses and the sensitivity of 25 parameters related to soil properties, nutrient transport and crop genetics. To avoid the one-sided risk of model prediction caused by using a single calibration criterion, the combined likelihood (CL) function integrated information concerning water, nitrogen, and crop production was introduced in GLUE analysis for the predictions of the following four model output responses: the total amount of water content (T-SWC) and the nitrate nitrogen (T-NIT) within the 1-m soil profile, the seed yields of waxy maize (Y-Maize) and winter wheat (Y-Wheat). In the process of evaluating RZWQM2, measurements and meteorological data were obtained from a field experiment that involved a winter wheat and waxy maize crop rotation system conducted from 2003 to 2004 in southern Beijing. The calibration and validation results indicated that RZWQM2 model can be used to simulate the crop growth and water-nitrogen migration and transformation in wheat-maize crop rotation planting system. The results of uncertainty analysis using of GLUE method showed T-NIT was sensitive to parameters relative to nitrification coefficient, maize growth characteristics on seedling period, wheat vernalization period, and wheat photoperiod. Parameters on soil saturated hydraulic conductivity, nitrogen nitrification and denitrification, and urea hydrolysis played an important role in crop yield component. The prediction errors for RZWQM2 outputs with CL function were relatively lower and uniform compared with other likelihood functions composed of individual calibration criterion. This

  15. Percutaneous sclerotherapy of massive venous malformations of the face and neck using fibrin glue combined with OK-432 and pingyangmycin.

    PubMed

    Chen, Wei-liang; Huang, Zhi-quan; Zhang, Da-ming; Chai, Qiang

    2010-04-01

    Surgical excision is useful only for localized and limited lesions. The purpose of this study was to evaluate the clinical curative effect of percutaneous sclerotherapy of massive venous malformations of the face and neck using fibrin glue combined with OK-432 and pingyangmycin. Eighteen patients with massive venous malformations were treated with an injection of fibrin glue combined with OK-432 and pingyangmycin. All the patients had extreme swelling postoperatively with no major complications. The follow-up period ranged from 6 to 12 months. Twelve lesions were completely involuted, 4 lesions were mostly involuted, and 2 lesions were partially involuted. All of the patients had normal liver and kidney functions. None of the patients presented with hematologic toxic effects or signs of pulmonary involvement. Percutaneous sclerotherapy using fibrin glue combined with OK-432 and pingyangmycin provided a simple, safe, and reliable alternative treatment for massive venous malformations.

  16. 21 CFR 182.3173 - Butylated hydroxytoluene.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Butylated hydroxytoluene. 182.3173 Section 182.3173 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) SUBSTANCES GENERALLY RECOGNIZED AS SAFE Chemical Preservatives § 182...

  17. 21 CFR 582.3173 - Butylated hydroxytoluene.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Butylated hydroxytoluene. 582.3173 Section 582.3173 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS SUBSTANCES GENERALLY RECOGNIZED AS SAFE Chemical Preservatives...

  18. 21 CFR 182.3169 - Butylated hydroxyanisole.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Butylated hydroxyanisole. 182.3169 Section 182.3169 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) SUBSTANCES GENERALLY RECOGNIZED AS SAFE Chemical Preservatives § 182...

  19. 21 CFR 582.3169 - Butylated hydroxyanisole.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Butylated hydroxyanisole. 582.3169 Section 582.3169 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS SUBSTANCES GENERALLY RECOGNIZED AS SAFE Chemical Preservatives...

  20. Etude de l'effet du gonflement par les solvants sur les proprietes du caoutchouc butyle

    NASA Astrophysics Data System (ADS)

    Nohile, Cedrick

    Polymers and in particular elastomers are widely used for personal protective equipment against chemical and biological hazards. Among them, butyl rubber is one of the most effective elastomers against chemicals. However, if this rubber has a very good resistance to a wide range of them, it is sensitive to non polar solvents. These solvents will easily swell the material and may dramatically affect its properties. This situation may involve a large risk for. butyl rubber protective equipment users. It is thus essential to improve the understanding of the effect of solvents on the properties of butyl rubber. The research that was carried out had two objectives: to identify the parameters controlling the resistance of butyl rubber to solvents and to study the effect of swelling on the properties of butyl rubber. The results show that the resistance of butyl rubber to solvents appears to be controlled by three main parameters: the chemical class of the solvent, its saturation vapor pressure and its molar volume. In addition, swelling affects butyl rubber mechanical properties in a permanent way. The effects can be attributed to the extraction of plasticizers by the solvent and to the degradation of the physico-chemical structure of the polymer network. This chemical degradation was linked to a phenomenon of differential swelling which seems to be controlled by the solvent flow inside the material. These results question some general beliefs within the field of protection against chemical risks. They also open new perspectives for the development of predictive tools relative to the behavior of butyl rubber in the presence of solvents

  1. A comparison of the application of fibrin glue and adhesive film for repair of anastomotic leaks in the rat.

    PubMed

    Ayhan, Baris; Erikoglu, Mehmet; Tavli, Süleyman S; Toy, Hatice

    2012-08-04

    Anastomotic leaks constitute one of the most serious intraoperative complications and although many studies have been devoted to finding a solution for this problem, none of them has yet been able offer a decisive, successful method. In this study, the ability of fibrin glue and adhesive film to repair anastomotic leaks in an experimental model was compared. The sample comprised four groups of seven rats: Group 1 (Control): the distal colon was transected and anastomosis was performed. Group 2 (Primary repair): incomplete anastomosis produced a leak that was closed by primary repair on day 3. Group 3 (Fibrin glue): incomplete anastomosis produced a leak that was closed by primary repair and fibrin glue applied on day 3. Group 4 (Adhesive film): incomplete anastomosis produced a leak that was closed by primary repair and adhesive film was applied on day 3. The rats were sacrificed on day 6 following anastomosis. Anastomotic blast compressions were measured and fibroblast activation, inflammation, neovascularization and levels of collagen were evaluated. The results from Group 4 showed that blast compression values were high and statistically significantly increased over control values (p < 0.05). Inflammation in Group 2 was significantly higher than the other groups (p < 0.05). No significant differences were detected in the comparison of the groups regarding the other scoring criteria (p > 0.05). Adhesive film is more effective in reducing anastomotic leakage than fibrin glue.

  2. Nonspecific esterase reaction in hyperplastic urinary bladder epithelium induced by administration of N-butyl-N-(4-hydroxybutyl)nitrosamine, freezing and formalin instillation in rats.

    PubMed Central

    Akagi, A.; Otsuka, H.

    1988-01-01

    Chronological changes in nonspecific esterase (NSE) activity in hyperplasia of the bladder mucosa in Wistar rats induced by the administration of 0.05% N-butyl-N-(4-hydroxybutyl)nitrosamine (BBN) in their drinking water for up to 20 weeks and in reversible regenerative hyperplasia by freeze ulceration and 20% formalin instillation in the bladder were compared. In regenerative hyperplasia foci with strong NSE activity could not be proved throughout the experimental period, while the foci were detected in hyperplastic epithelium induced by BBN treatment for more than 3 weeks. The focus of NSE high activity persisted for 56 weeks after withdrawal of the carcinogen and the focus or area with the same NSE reaction appeared in papilloma and transitional cell carcinoma seen in weeks 7 to 20 of BBN treatment. The appearance of focal strong activity of NSE seemed to be a promising marker for the precursor lesions of bladder tumors. Short uniform, pleomorphic microvilli were observed on the cell surface of preneoplastic and carcinomatous lesions by BBN as well as on that of regenerative hyperplasia after freeze ulceration and formalin instillation. Images Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig. 13 PMID:3390388

  3. Calibrations for Charged Particle Tracking with the GlueX Detector

    NASA Astrophysics Data System (ADS)

    Staib, Michael; GlueX Collaboration

    2015-10-01

    Two gas detectors comprise the tracking system for the GlueX experiment, the Central Drift Chamber (CDC) and the Forward Drift Chamber (FDC). The CDC is a cylindrical straw-tube detector covering polar angles between 6° and 168°, delivering spatial resolution of ~150 μm. The FDC is a Cathode Strip Chamber consisting of four packages, each with six alternating layers of anode wires and cathode strips. The FDC is designed to track forward-going charged particles with polar angles between 1° and 20° with a spatial resolution of ~200 μm. Both tracking detectors record timing information and energy loss measurements useful for particle identification. During Fall 2014 and Spring 2015, the first photon beam was delivered on target for commissioning of the GlueX detector in Hall-D at Jefferson Lab. These data are currently being used in a large effort to calibrate the individual detector subsystems to achieve design performance. Methods and results for calibrations of each of the tracking detectors are presented. Techniques for alignment of the tracking system using a combination of cosmic rays and beam data is discussed. Finally, some early results of physics measurements including charged final-state particles are presented. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under Contract DE-AC05-06OR23177.

  4. To compare the effect of camylofin dihydrochloride (anafortin) with combination of valethamate bromide (epidosin) and hyoscine butyl-N-bormide (buscopan) on cervical dilation.

    PubMed

    Sarbhjit, Kaur; S K, Bajwa; Parmjit, Kaur; Surinder, Bhupal

    2013-09-01

    Various drugs have been tried to hasten cervical dilatation so that problems and hazards of prolonged labour both for the mother and fetus are minimised without increasing maternal or perinatal mortality and morbidity. To compare the effect of camylofin dihydrochloride with combination of valethemate bromide (epidosin) & hyoscine N butyl bromide (buscopan) on cervical dilatation, evaluate the incidence of side effects and to look for neonatal outcome. Two hundred cases were included of primigravidae or multigravidae with gestational age of 37 to 40 weeks with full term with single foetus,vertex presentation and no major antenatal complication of women in labour, admitted to labour room of gynaecology Department, Government Medical College, Patiala, India, was studied and divided into 2 groups Group A-100 Cases - labour accelerated by camylofin dihydro chloride and Group B-100 Cases-labour accelerated by valethemate bromide (epidosin) and hyoscine N butyl bromide. The mean age, parity and period of gestation in Anafortan group was 24.13 ± 3.60 years, 49% primigravidae and 51% multigravidae and 38.81 ± 1.09 weeks, while that in Epidosin + Buscopan group was 24.43 ± 3.42 years, 45% primigravidae and 51% multigravidae and 38.94 ± 1.09 weeks respectively. The difference was insignificant and both the groups were comparable. Mean duration of Active phase of 1st stage of labor was 141.40 ± 55.41 minutes in Anafortan group and 181.46 ± 75.58 minutes in Epidosin + Buscopan group. Mean rate of cervical dilatation according to active phase of first stage was 3.33 ± 1.03 cm/hours in Anafortan group and 2.69 ± 1.03 cm/hr in Epidosin + Buscopan group. The difference between the two groups is highly significant (p < 0.01) thus it is concluded that Anafortan hastened the rate of cervical dilatation.

  5. tert-Butyl 6-amino-5-cyano-2-(2-meth­oxy­eth­yl)nicotinate

    PubMed Central

    Chen, Yi-Ning; Zhao, Xing-Dong; Deng, Jie; Li, Qin-Geng

    2012-01-01

    The title compound, C14H19N3O3, was synthesized by the reaction of 3-meth­oxy­propionitrile, tert-butyl bromo­acetate and eth­oxy­methyl­enemalononitrile. In the crystal, N—H⋯O hydrogen bonds link the mol­ecules into chains propagating along the b axis. PMID:22737103

  6. REDUCTIVE ACTIVATION OF DIOXYGEN FOR DEGRADATION OF METHYL TERT-BUTYL ETHER BY BIFUNCTION

    EPA Science Inventory

    Bifunctional aluminum is prepared by sulfating aluminum metal with sulfuric acid. The use of bifunctional aluminum to degrade methyl tert-butyl ether (MTBE) in the presence of dioxygen has been examined using batch systems. Primary degradation products were tert-butyl alcohol, ...

  7. A first look at reconstructed data from the GlueX detector

    NASA Astrophysics Data System (ADS)

    Taylor, Simon; GlueX Collaboration

    2015-10-01

    Construction of the GlueX detector in Hall D at the Thomas Jefferson National Accelerator Facility has recently been completed as part of the 12 GeV Upgrade to the facility. The detector consists of a barrel region containing devices for tracking charged particles and a lead-scintillator calorimeter for detecting photons, and a forward region consisting of two layers of scintillator paddles for time-of-flight measurements and a lead-glass electromagnetic calorimeter. The electron beam from the accelerator is converted into a photon beam by inserting a diamond radiator, thereby producing a coherent bremsstrahlung spectrum of photons impinging on a 30 cm-long LH2 target. The energy of the photon beam is determined using a tagging spectrometer. A commissioning run took place in Spring of 2015 during which all of the detector components were read out. Preliminary calibrations have been determined to a level sufficient to allow reconstruction of final states with several charged tracks and neutral particles. A first look at results of reconstruction of events using the GlueX detector will be presented. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under Contract DE-AC05-06OR23177.

  8. KTP laser assisted endoscopic tissue fibrin glue biocauterization for congenital pyriform sinus fistula in children.

    PubMed

    Huang, Yun-Chen; Peng, Steve Shinn-Forng; Hsu, Wei-Chung

    2016-06-01

    This study aims to assess the efficacy of a novel endoscopic management for congenital pyriform sinus fistula (CPSF) using potassium titanyl phosphate (KTP) laser assisted endoscopic tissue fibrin glue biocauterization in children. From 2010 to 2014, a total of 5 children with recurrent or acute suppurative thyroiditis or neck abscess secondary to CPSF were enrolled retrospectively in this study. Mean age at the first time of endoscopic biocauterization was 6.2 ± 0.7 (5-7) years. The barium swallow study detected a fistula in four cases. Endoscopy identified an internal opening at the pyriform sinus in all cases with four on the left side and one on the right side. All patients underwent KTP laser assisted endoscopic tissue fibrin glue biocauterization as treatment for CPSF. Only one case required the second endoscopic procedure due to fluctuation of symptoms. Post-endoscopic follow-up duration of these patients was 24.6 ± 11.6 (7-36) months. Neither complications nor recurrences were noted during follow-up in all patients. For children presenting with repeated acute suppurative thyroiditis or neck infections, clinicians should highly suspect the possibility of CPSF. Endoscopy should be performed not only to confirm the diagnosis but also could be served as an initial treatment modality of biocauterization by KTP laser and tissue fibrin glue, which was demonstrated as a less invasive, safe, and effective method in children. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (Etbe) ...

    EPA Pesticide Factsheets

    The IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE) was released for external peer review in June 2017. EPA’s Science Advisory Board’s (SAB) Chemical Assessment Advisory Committee (CAAC) will conduct a peer review of the scientific basis supporting the ETBE assessment and release a final report of their review. Information regarding the peer review can be found on the SAB website. EPA is conducting an Integrated Risk Information System (IRIS) health assessment for Ethyl Tertiary Butyl Ether (ETBE). The outcome of this project is a Toxicological Review and IRIS Summary for ETBE that will be entered into the IRIS database.

  10. ``Glue" approximation for the pairing interaction in the Hubbard model with next nearest neighbor hopping

    NASA Astrophysics Data System (ADS)

    Khatami, Ehsan; Macridin, Alexandru; Jarrell, Mark

    2008-03-01

    Recently, several authors have employed the ``glue" approximation for the Cuprates in which the full pairing vertex is approximated by the spin susceptibility. We study this approximation using Quantum Monte Carlo Dynamical Cluster Approximation methods on a 2D Hubbard model. By considering a reasonable finite value for the next nearest neighbor hopping, we find that this ``glue" approximation, in the current form, does not capture the correct pairing symmetry. Here, d-wave is not the leading pairing symmetry while it is the dominant symmetry using the ``exact" QMC results. We argue that the sensitivity of this approximation to the band structure changes leads to this inconsistency and that this form of interaction may not be the appropriate description of the pairing mechanism in Cuprates. We suggest improvements to this approximation which help to capture the the essential features of the QMC data.

  11. Mid- and long-term outcomes of carotid-cavernous fistula endovascular management with Onyx and n-BCA: experience of a single tertiary center.

    PubMed

    Barber, Sean M; Rangel-Castilla, Leonardo; Zhang, Y Jonathan; Klucznik, Richard; Diaz, Orlando

    2015-10-01

    Endovascular therapy is the preferred treatment for most carotid-cavernous fistulas (CCFs). Early reports have documented excellent initial clinical and radiographic outcomes after embolization of CCFs with Onyx or n-butyl cyanoacrylate (n-BCA), but little evidence is available about the long-term durability of this technique. To characterize the long-term durability of CCF liquid embolization. The authors retrospectively reviewed a database of 24 CCFs in 21 consecutive patients who underwent Onyx or n-BCA embolization of a CCF from 2006 to 2013 at our institution. A total of 25 Onyx or n-BCA embolization procedures were attempted and 24 successfully completed during the study, resulting in complete or near-complete occlusion by the end of the study in all 24 CCFs (obliteration success, 100%). Attempted embolization in a single CCF failed initially, but was performed successfully at a later date by a different approach. None of the 24 CCFs recanalized, regrew, or required any further treatment subsequent to Onyx or n-BCA embolization throughout a mean 12.4 months of angiographic follow-up (range 1-36 months). Clinically significant complications were seen in three embolization procedures, including cranial nerve palsies (n=1), embolic infarct (n=1), and intraperitoneal hemorrhage (n=1). Early evidence has indicated that endovascular embolization with Onyx is relatively safe and effective at achieving an initial angiographic cure for CCFs. Results of our series suggest that angiographic and clinical outcomes of Onyx and n-BCA embolization remain stable at mid- and long-term follow-up. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Expression of an alkane monooxygenase (alkB) gene and methyl tert-butyl ether co-metabolic oxidation in Pseudomonas citronellolis.

    PubMed

    Bravo, Ana Luisa; Sigala, Juan Carlos; Le Borgne, Sylvie; Morales, Marcia

    2015-04-01

    Pseudomonas citronellolis UAM-Ps1 co-metabolically transforms methyl tert-butyl ether (MTBE) to tert-butyl alcohol with n-pentane (2.6 mM), n-octane (1.5 mM) or dicyclopropylketone (DCPK) (4.4 mM), a gratuitous inducer of alkane hydroxylase (AlkB) activity. The reverse transcription quantitative real-time PCR was used to quantify the alkane monooxygenase (alkB) gene expression. The alkB gene was expressed in the presence of n-alkanes and DCPK and MTBE oxidation occurred only in cultures when alkB was transcribed. A correlation between the number of alkB transcripts and MTBE consumption was found (ΜΤΒΕ consumption in μmol = 1.44e(-13) x DNA copies, R(2) = 0.99) when MTBE (0.84 mM) was added. Furthermore, alkB was cloned and expressed into Escherichia coli and the recombinant AlkB had a molecular weight of 42 kDa. This is the first report where the expression of alkB is related to the co-metabolic oxidation of MTBE.

  13. The structural genes for three Drosophila glue proteins reside at a single polytene chromosome puff locus.

    PubMed Central

    Crowley, T E; Bond, M W; Meyerowitz, E M

    1983-01-01

    The polytene chromosome puff at 68C on the Drosophila melanogaster third chromosome is thought from genetic experiments to contain the structural gene for one of the secreted salivary gland glue polypeptides, sgs-3. Previous work has demonstrated that the DNA included in this puff contains sequences that are transcribed to give three different polyadenylated RNAs that are abundant in third-larval-instar salivary glands. These have been called the group II, group III, and group IV RNAs. In the experiments reported here, we used the nucleotide sequence of the DNA coding for these RNAs to predict some of the physical and chemical properties expected of their protein products, including molecular weight, amino acid composition, and amino acid sequence. Salivary gland polypeptides with molecular weights similar to those expected for the 68C RNA translation products, and with the expected degree of incorporation of different radioactive amino acids, were purified. These proteins were shown by amino acid sequencing to correspond to the protein products of the 68C RNAs. It was further shown that each of these proteins is a part of the secreted salivary gland glue: the group IV RNA codes for the previously described sgs-3, whereas the group II and III RNAs code for the newly identified glue polypeptides sgs-8 and sgs-7. Images PMID:6406838

  14. The tert-butyl cation on zeolite Y: A theoretical and experimental study

    NASA Astrophysics Data System (ADS)

    Rosenbach, Nilton, Jr.; dos Santos, Alex P. A.; Franco, Marcelo; Mota, Claudio J. A.

    2010-01-01

    The structure and energy of the tert-butyl cation on zeolite Y were calculated at ONIOM(MP2(FULL)/6-31G( d, p):MNDO) level. The results indicated that the tert-butyl cation is a minimum and lies between 40 and 51 kJ mol -1 above in energy to the tert-butoxide, depending on the level of calculation. Both species are stabilized through hydrogen bonding interactions with the framework oxygen atoms. Experimental data of nucleophilic substitution of tert-butylchloride and bromide over NaY impregnated with NaCl or NaBr give additional support for the formation of the tert-butyl cation as a discrete intermediate on zeolite Y, in agreement with the calculations.

  15. Glue ear: how good is the information on the World Wide Web?

    PubMed

    Ritchie, L; Tornari, C; Patel, P M; Lakhani, R

    2016-02-01

    This paper objectively evaluates current information available to the general public related to glue ear on the World Wide Web. The term 'glue ear' was typed into the 3 most frequently used internet search engines - Google, Bing and Yahoo - and the first 20 links were analysed. The first 400 words of each page were used to calculate the Flesch-Kincaid readability score. Each website was subsequently graded using the Discern instrument, which gauges quality and content of literature. The websites Webmd.boots.com, Bupa.co.uk and Patient.co.uk received the highest overall scores. These reflected top scores in either readability or Discern instrument assessment, but not both. Readability and Discern scores increased with the presence of a marketing or advertising incentive. The Patient.co.uk website had the highest Discern score and third highest readability score. There is huge variation in the quality of information available to patients on the internet. Some websites may be accessible to a wide range of reading ages but have poor quality content, and vice versa. Clinicians should be aware of indicators of quality, and use validated instruments to assess and recommend literature.

  16. Regioisomer-Free C 4h β-Tetrakis(tert-butyl)metallo-phthalocyanines: Regioselective Synthesis and Spectral Investigations.

    PubMed

    Iida, Norihito; Tanaka, Kenta; Tokunaga, Etsuko; Takahashi, Hiromi; Shibata, Norio

    2015-04-01

    Metal β-tetrakis(tert-butyl)phthalocyanines are the most commonly used phthalocyanines due to their high solubility, stability, and accessibility. They are commonly used as a mixture of four regioisomers, which arise due to the tert-butyl substituent on the β-position, and to the best of our knowledge, their regioselective synthesis has yet to be reported. Herein, the C 4h -selective synthesis of β-tetrakis(tert-butyl)metallophthalocyanines is disclosed. Using tetramerization of α-trialkylsilyl phthalonitriles with metal salts following acid-mediated desilylation, the desired metallophthalocyanines were obtained in good yields. Upon investigation of regioisomer-free zinc β-tetrakis(tert-butyl)phthalocyanine using spectroscopy, the C 4h single isomer described here was found to be distinct in the solid state to zinc β-tetrakis(tert-butyl)phthalocyanine obtained by a conventional method.

  17. Efficient nitrogen incorporation in GaAs using novel metal organic As-N precursor di-tertiary-butyl-arsano-amine (DTBAA)

    NASA Astrophysics Data System (ADS)

    Sterzer, E.; Beyer, A.; Duschek, L.; Nattermann, L.; Ringler, B.; Leube, B.; Stegmüller, A.; Tonner, R.; von Hänisch, C.; Stolz, W.; Volz, K.

    2016-04-01

    III/V semiconductors containing small amounts of nitrogen (N; dilute nitrides) are discussed in the context of different solar cell and laser applications. The efficiency of these devices is negatively affected by carbon (C) incorporation, which comes either from the direct C-N bond in the N precursor unsymmetrical 1,1-dimethylhydrazine (UDMHy) used conventionally or from the alkyl groups of the conventional precursors for gallium (Ga), indium and arsenic (As) containing carbon. This C is incorporated together with the N due to the strength of the C-N bond. A further important issue in dilute nitride growth is the very low N incorporation efficiency in the crystal from UDMHy, which can be as little as 1% of the N supplied in the gas phase. Therefore, new metal organic chemicals have to be synthesized and their growth characteristics and suitability for dilute nitride growth have to be explored. This work presents the chemical di-tertiary-butyl-arsano-amine (DTBAA), which was synthesized, purified and tested as an N precursor for metal organic vapor phase epitaxy (MOVPE). Computational investigations show β-hydrogen and isobutane elimination to be the main reaction channel in the gas phase with high reaction barriers and absence of small fragments containing C as products. The loss of N via N2, as in UDMHy, can be excluded for unimolecular reactions of DTBAA. The Ga(NAs)/GaAs heterostructures were grown by MOVPE as initial test material and a systematic N incorporation study is presented in this paper. It is shown that high quality Ga(NAs) can be grown using DTBAA. The N incorporation was confirmed by high resolution X-ray diffraction and photoluminescence studies. All samples grown exhibit as grown room temperature photoluminescence and smooth surface morphologies. Furthermore, DTBAA shows extremely high N incorporation efficiency, which makes this molecule a very promising candidate for further research into dilute nitride material growth.

  18. PREPARATION OF BLOCK COPOLYMERS OF POLY(STYRENE) AND POLY(T-BUTYL ACRYLATE) OF VARIOUS MOLECULAR WEIGHTS AND ARCHITECTURES BY ATOM TRANSFER RADICAL POLYMERIZATION. (R826735)

    EPA Science Inventory

    Block copolymers of polystyrene and poly(t-butyl acrylate) were prepared using atom transfer radical polymerization techniques. These polymers were synthesized with a CuBr/N,N,N,NResearch of obtaining TiO2 by sol-gel method using titanium isopropoxide TIP and tetra-n-butyl orthotitanate TNB

    NASA Astrophysics Data System (ADS)

    Gómez de Salazar, J. M.; Nutescu Duduman, C.; Juárez Gonzalez, M.; Palamarciuc, I.; Barrena Pérez, M. I.; Carcea, I.

    2016-08-01

    Titanium dioxide crystallises in three polymorphs: anatase, rutile and brookite. Rutile is most stable form of the TiO2 polymorphs. In this paper we concentrate on obtaining rutile and anatase, both used in various applications. The chosen method is sol-gel, which is a reliable method used for obtaining titanium oxides. We prepared titanium dioxide with using titanium isopropoxide (TIP) with chemical construction (C12H28O4Ti) and tetra-n-butyl orthotitanate (TNB) with chemical construction (C16H36O4Ti). The experiments were carried out in order to compare the results of the samples with similar reaction conditions, but with different precursors, thus concluding which precursor gives best results. Using different analysis techniques as X-ray Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FTIR), Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM) and Thermogravimetric Analysis (TGA) we characterised the samples morphologically and structurally.

  19. Hypothyroidism protects di(n-butyl) phthalate-induced reproductive organs damage in Sprague-Dawley male rats.

    PubMed

    Lee, Ena; Kim, Hee Jin; Im, Ji Young; Kim, Jeonga; Park, Hyeyoung; Ryu, Ju Young; Lee, Jaewon; Shim, Keun Aee; Jung, Kee Kyung; Han, Soon Young; Lee, Byung Mu; Kim, Seung Hee; Kim, Hyung Sik

    2008-08-01

    This study examined the deleterious effects of di(n-butyl) phthalate (DBP) on the male reproductive organs in hypothyroid rats. Hypothyroidism was induced in prepubertal male rats (28 days of age) by an intraperitonial (i.p.) injection of 10 mg/kg/day propylthiouracil (PTU) for 30 days. DBP (100 and 500 mg/kg/day) was administered by oral gavages to the intact or hypothyroid rats for 30 days. The body weight of the PTU-treated rats was significantly lower than the control group. The total triiodothyronine (T3) and thyroxine (T4) serum level was lower, and the thyroid-stimulating hormone (TSH) level was higher in the hypothyroid rats than in the control rats. The DBP treatment rats showed significantly lower testes, epididymides, seminal vesicles, and ventral prostate weights than the untreated rats. The hypothyroid rats had significantly higher thyroid weights and lower adrenal glands weights than the control rats. The histomorphological examination showed diffused Leydig cells hyperplasias and germ cells loss in the DBP (500 mg/kg)-treated rats, whereas these effects were mild in the DBP-treated hypothyroid rats. The serum levels of monobutyl phthalate (MBP) were significantly lower in PTU-induced hypothyroid rats than in the DBP-treated rats. This data suggests that the hypothyroid status might offer some protection from male reproductive organ toxicity caused by a disturbance in the metabolic activation of the parent compound, DBP.