Sample records for nail plate model

  1. [Should one choose the nail or the plate in treating a leg fracture?].

    PubMed

    Vives, P; Massy, E; Dubois, P; Decoopmann, P

    1975-12-01

    The authors have analysed the results of 126 tibial fractures treated by blind nailing with reaming and 112 tibial fractures treated by plating. They noted 5 septic complications after nailing, after plating, one non-union after nailing and 12 after plating, 3 malunions after nailing and 2 after plating. The cases treated by nailing united earlier. The Authors conclude that nailing is a more fiable technique than plating, and that the only fractures which should be plated are those which are not fit for nailing.

  2. Comparative study between biologic plating and intramedullary nailing for the treatment of subtrochanteric fractures: Is biologic plating using LCP-DF superior to intramedullary nailing?

    PubMed

    Shin, Won Chul; Moon, Nam Hoon; Jang, Jae Hoon; Lee, Hee Jin; Suh, Kuen Tak

    2017-10-01

    The objective of this study is to evaluate the outcome measures of subtrochanteric fractures between biologic plating and intramedullary nailing and determine if biologic plating is superior to intramedullary nailing. Between March 2009 and December 2015, 81 patients with subtrochanteric fractures were enrolled (52 males and 29 females; 31 treated with biologic plating and 50 with intramedullary nailing). Biologic plating was conducted consecutively between May 2011 and March 2013 and intramedullary nailing was performed for the rest of period. Perioperative outcomes including operation time and blood loss during the operation; postoperative radiologic outcomes including union, time to union, coronal alignment, and shortening of the femur; and clinical outcomes including walking ability and pain were evaluated. The biologic plating group was compared with the intramedullary nailing group as a historical control. No significant differences were identified for bony union and time to union between the two different fixation methods Coronal alignment was significantly better in the biologic plating group than in the intramedullary nailing group (p<0.016). Postoperative coronal alignment was the only risk factor associated with the nonunion of subtrochanteric fractures (unadjusted OR: 1.915, 95% CI: 0.190 - 19.273; adjusted OR: 0.042, 95% CI: 0.000 - 21.517; p=0.320). Surgical outcomes using LCP-DF are comparable to those using intramedullary nailing. Further clinical studies with a larger sample size are required to show the advantage of biologic plating for the treatment of subtrochanteric fractures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Augmentation plating in management of failed femoral nailing.

    PubMed

    Verma, Rahul; Sharma, Pulak; Gaur, Sanjiv

    2017-08-01

    Non-union following interlocking nailing is a troubling complication in treatment of shaft femur fractures. There is no clear consensus on the treatment of this problem. This research was undertaken to study the role of augmentation plating combined with exchange nailing in such cases. A prospective clinical study was undertaken from January 2010 to December 2015. Patients with aseptic femoral shaft non-union, with or without implant failure following intramedullary nailing were included in the study. Augmentation plating combined with Exchange Nailing with a 4.5mm LCP was done. Fifteen patients (nine male and six female) with an average age of 43.7 years (range 18-67 years) were treated. Average timing from the first surgery was 7.3 months. Complete clinical and radiological union was achieved in all cases in a mean duration of 5.2 months. Average duration of follow up was 12.6 months. All the patients retained the preoperative hip and knee range of motion till the last follow up. Augmentation plating combined with exchange nailing in non-unions following intramedullary nailing of femur shaft fractures is a reasonably good and effective procedure with a very high success rate. © 2017 Elsevier Ltd. All rights reserved.

  4. Biomechanical comparison of blade plate and intramedullary nail fixation for tibiocalcaneal arthrodesis.

    PubMed

    Lee, Arthur T; Sundberg, Eric B; Lindsey, Derek P; Harris, Alex H S; Chou, Loretta B

    2010-02-01

    Tibiocalcaneal arthrodesis is an uncommon salvage procedure used for complex problems of the ankle and hindfoot. A biomechanical evaluation of the fixation constructs of this procedure has not been studied previously. The purpose of this study was to compare intramedullary nail to blade plate fixation in a deformity model in fatigue endurance testing and load to failure. Nine matched pairs of fresh frozen cadaveric legs underwent talectomy followed by fixation with a blade plate and 6.5-mm fully threaded cancellous screw or an ankle arthrodesis intramedullary nail. The specimens were loaded to 270 N at a rate of 3 Hz for a total of 250,000 cycles, followed by loading to failure. Intramedullary nail fixation demonstrated greater mean stiffness throughout the fatigue endurance testing, from cycles 10 through 250,000 (blade plate versus intramedullary nail; cycle 10, 93 +/- 34 N/mm versus 117 +/- 40 N/mm (t = 2.33, p = 0.04); cycle 100, 89 +/- 34 N/mm versus 118 +/- 42 N/mm (t = 3.16, p = 0.01); cycle 1000, 86 +/- 32 N/mm versus 120 +/- 45 N/mm (t = 3.52, p = 0.01); cycle 10,000, 83 +/- 36 N/mm versus 128 +/- 50 N/mm (t = 3.80, p = 0.01); cycle 100,000, 82 +/- 34 N/mm versus 126 +/- 52 N/mm (t = 3.70, p = 0.01); cycle 250,000, 80 +/- 31 N/mm versus 125 +/- 49 N/mm (t = 4.2, p = 0.003). There was no statistically significant difference between the intramedullary nail and blade plate fixation in cycle one or in load to failure; cycle 10, blade plate 70 +/- 38 N/mm and intramedullary nail 67 +/- 20 N/mm (t = 0.60, p = 0.56); load to failure, blade plate 808 +/- 193 N, IMN 1074 +/- 290 N) (p = 0.15). Intramedullary nail fixation was biomechanically superior to blade plate and screw fixation in a tibiocalcaneal arthrodesis construct. The ankle arthrodesis intramedullary nail provides greater stiffness for fixation in tibiocalcaneal arthrodesis, which may improve healing.

  5. Pediatric Diaphyseal Femur Fractures: Submuscular Plating Compared With Intramedullary Nailing.

    PubMed

    Sutphen, Sean A; Mendoza, Juan D; Mundy, Andrew C; Yang, Jingzhen G; Beebe, Allan C; Samora, Walter P; Klingele, Kevin E

    2016-11-01

    This study compared the radiographic and clinical outcomes of pediatric diaphyseal femur fractures treated by submuscular plating, flexible retrograde intramedullary nailing, or rigid antegrade intramedullary nailing with a trochanteric entry point in skeletally immature patients who were 8 years and older. A retrospective review was conducted of skeletally immature patients 8 years and older who were treated for femur fracture with submuscular plating, flexible intramedullary nailing, or rigid intramedullary nailing from 2001 to 2014 with a minimum 12-week follow-up. Treatment outcomes were compared for statistical significance, including time to union, malunion, nonunion, heterotopic ossification, avascular necrosis, time to full weight bearing, limb length discrepancy, residual limp, painful hardware, and infection. The study identified 198 femur fractures in 196 patients (mean age, 11.9 years). Each femur fracture was treated with submuscular plating (35), flexible intramedullary nailing (61), or rigid intramedullary nailing (102). Mean follow-up across the cohort was 48 weeks, ranging from 12 to 225 weeks. Flexible nailing was associated with an increased incidence of malunion (P<.0001) and hardware irritation (P=.0204) and longer time to full weight bearing (P=.0018). Rigid nailing was associated with an increased incidence of limp at 12-week followup (P=.0412). Additionally, 23.5% of patients who were treated with rigid nailing had heterotopic ossification. Of all surgical methods, submuscular plating allowed for the most rapid return to full weight bearing (mean, 7 weeks) and offered the fastest healing rate (mean, 6 weeks). Submuscular plating resulted in faster times to union and full weight bearing, with minimal complication rates. Rigid intramedullary nailing with trochanteric entry resulted in a lower incidence of malunion and hardware-related complications; however, these patients had an increased incidence of heterotopic ossification and residual

  6. Size and Charge Dependence of Ion Transport in Human Nail Plate

    PubMed Central

    Baswan, Sudhir M.; Li, S. Kevin; LaCount, Terri D.; Kasting, Gerald B.

    2016-01-01

    The electrical properties of human nail plate are poorly characterized, yet are a key determinate of the potential to treat nail diseases such as onychomycosis using iontophoresis. In order to address this deficiency, molar conductivities of 17 electrolytes comprising 12 ionic species were determined in hydrated human nail plate in vitro. Cation transport numbers across the nail for 11 of these electrolytes were determined by the electromotive force method. Effective ionic mobilities and diffusivities at infinite dilution for all ionic species were determined by regression analysis. The ratios of diffusivities in nail to those in solution were found to correlate inversely with the hydrodynamic radii of the ions according to a power law relationship having an exponent of −1.75 ± 0.27, a substantially steeper size dependence than observed for similar experiments in skin. Effective diffusivities of cations in nail were three-fold higher than those of comparably sized anions. These results reflect the strong size and charge selectivity of the nail plate for ionic conduction and diffusion. The analysis implies that efficient transungual iontophoretic delivery of ionized drugs having radii upwards of 5 Å (approximately MW ≥ 340 Da) will require chemical or mechanical alteration of the nail plate. PMID:26886342

  7. Size and Charge Dependence of Ion Transport in Human Nail Plate.

    PubMed

    Baswan, Sudhir M; Li, S Kevin; LaCount, Terri D; Kasting, Gerald B

    2016-03-01

    The electrical properties of human nail plate are poorly characterized yet are a key determinate of the potential to treat nail diseases, such as onychomycosis, using iontophoresis. To address this deficiency, molar conductivities of 17 electrolytes comprising 12 ionic species were determined in hydrated human nail plate in vitro. Cation transport numbers across the nail for 11 of these electrolytes were determined by the electromotive force method. Effective ionic mobilities and diffusivities at infinite dilution for all ionic species were determined by regression analysis. The ratios of diffusivities in nail to those in solution were found to correlate inversely with the hydrodynamic radii of the ions according to a power law relationship having an exponent of -1.75 ± 0.27, a substantially steeper size dependence than observed for similar experiments in skin. Effective diffusivities of cations in nail were 3-fold higher than those of comparably sized anions. These results reflect the strong size and charge selectivity of the nail plate for ionic conduction and diffusion. The analysis implies that efficient transungual iontophoretic delivery of ionized drugs having radii upward of 5 Å (molecular weight, ca. ≥ 340 Da) will require chemical or mechanical alteration of the nail plate. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  8. Anterior augmentation plating of aseptic humeral shaft nonunions after intramedullary nailing.

    PubMed

    Gessmann, Jan; Königshausen, Matthias; Coulibaly, Marlon Osman; Schildhauer, Thomas Armin; Seybold, Dominik

    2016-05-01

    Humeral shaft nonunion after intramedullary nailing is a rare but serious complication. Treatment options include implant removal, open plating, exchange nailing and external fixation. The objective of this retrospective study was to determine whether augmentation plating without nail removal is feasible for treating a humeral shaft nonunion. Between 2002 and 2014, 37 patients (mean age 51, range 20-84 years) with aseptic humeral shaft nonunions prior to intramedullary nailing were treated with augmentation plating. The initial fractures had been fixed with retrograde nails (10 cases) or anterograde nails (27 cases). There were 34 atrophic nonunions and 3 hypertrophic nonunions. Nonunion treatment of all patients consisted of local debridement through an anterior approach to the humerus and anterior placement of the augmentation plates. Supplemental bone grafting was performed in all atrophic nonunion cases. All patients were followed until union was radiologically confirmed. Union was achieved in 36 patients (97 %) after a mean of 6 months (range 3-24 months). There was one case of iatrogenic median nerve palsy that showed complete spontaneous recovery 6 weeks postoperatively. One patient sustained a peri-implant stress fracture that was treated successfully by exchanging the augmentation plate to bridge the nonunion and the fracture. No infections or wound healing complications developed. At a mean follow-up of 14 months, all patients showed free shoulder and elbow motion and no restrictions in daily or working life. The results indicate that augmentation plating using an anterior approach is a safe and reliable option for humeral shaft nonunions after failed nailing, and the treatment has no substantial complications. Because the healing rates are similar to the standard technique of nail removal and fixation by compression or locking plates, we consider this technique to be an alternative choice for treatment.

  9. Ciclopirox delivery into the human nail plate using novel lipid diffusion enhancers.

    PubMed

    Hafeez, Farhaan; Hui, Xiaoying; Selner, Marc; Rosenthal, Bert; Maibach, Howard

    2014-06-01

    Onychomycosis is a common fungal infection of the nail plate and bed that affects up to 14% of the population and can have a substantial impact on the quality of life of those affected. This study compared the onychopharmacokinetics, nail absorption, nail distribution, and nail penetration of [(14)C]-ciclopirox dissolved in novel lipid diffusion enhancers with that of a commercial ciclopirox nail lacquer using the in vitro finite dose model. The penetration rate of ciclopirox was determined by applying doses of topical formulation twice daily to human nail plates for 11 d. Drug absorption was then measured by monitoring its rate of appearance in each nail layer and in the cotton pad/nail supporting bed. After a multiple day treatment, cumulative concentrations of ciclopirox formulated with lipid enhancers in the deep nail layer and the nail bed were significantly greater than cumulative concentrations of the commercial ciclopirox lacquer (p < 0.001) as well as several orders of magnitude greater than the minimal inhibitory concentration (MIC) deemed necessary to inhibit the growth of the causative dermatophyte species. When formulated with lipid enhancers, the amount of ciclopirox in the ventral/intermediate layer and supporting bed dramatically exceed the inhibitory concentration of ciclopirox for the most common onychomycosis organisms. These results suggest that topical ciclopirox with lipid enhancers has the potential to be an effective topical treatment for onychomycosis, and the lipidic pathway of the nail can be utilized as a means of effective transungual delivery.

  10. Interlocking Nailing Versus Interlocking Plating in Intra-articular Calcaneal Fractures: A Biomechanical Study.

    PubMed

    Reinhardt, Sophia; Martin, Heiner; Ulmar, Benjamin; Döbele, Stefan; Zwipp, Hans; Rammelt, Stefan; Richter, Martinus; Pompach, Martin; Mittlmeier, Thomas

    2016-08-01

    Open reduction and internal fixation with a plate is deemed to represent the gold standard of surgical treatment for displaced intra-articular calcaneal fractures. Standard plate fixation is usually placed through an extended lateral approach with high risk for wound complications. Minimally invasive techniques might avoid wound complications but provide limited construct stability. Therefore, 2 different types of locking nails were developed to allow for minimally invasive technique with sufficient stability. The aim of this study was to quantify primary stability of minimally invasive calcaneal interlocking nail systems in comparison to a variable-angle interlocking plate. After quantitative CT analysis, a standardized Sanders type IIB fracture model was created in 21 fresh-frozen cadavers. For osteosynthesis, 2 different interlocking nail systems (C-Nail; Medin, Nov. Město n. Moravě, Czech Republic; Calcanail; FH Orthopedics SAS; Heimsbrunn, France) as well as a polyaxial interlocking plate (Rimbus; Intercus GmbH; Rudolstadt, Germany) were used. Biomechanical testing consisted of a dynamic load sequence (preload 20 N, 1000 N up to 2500 N, stepwise increase of 100 N every 100 cycles, 0.5 mm/s) and a load to failure sequence (max. load 5000 N, 0.5 mm/s). Interfragmentary movement was detected via a 3-D optical measurement system. Boehler angle was measured after osteosynthesis and after failure occurred. No significant difference regarding load to failure, stiffness, Boehler angle, or interfragmentary motion was found between the different fixation systems. A significant difference was found with the dynamic failure testing sequence where 87.5% of the Calcanail implants failed in contrast to 14% of the C-Nail group (P < .01) and 66% of the Rimbus plate. The highest load to failure was observed for the C-Nail. Boehler angle showed physiologic range with all implants before and after the biomechanical tests. Both minimally invasive interlocking nail systems

  11. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    PubMed

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate

  12. Interlocking Nailing Versus Plating in Tibial Shaft Fractures in Adults: A Comparative Study.

    PubMed

    Mukherjee, Sagnik; Arambam, Mahendra Singh; Waikhom, Sanjib; Santosha; Masatwar, Pranav Vitthal; Maske, Rohan Gautam

    2017-04-01

    Tibial diaphyseal fractures are the commonest long bone fractures in adults, most commonly managed by intramedullary interlocking nailing. However, several meta-analysis show that locking plate osteosynthesis is equally effective in managing tibial diaphyseal fractures and are associated with less number of complications. To compare the results of fixation of tibial fractures following plating and nailing in terms of union, patient satisfaction and complications. A hospital based non randomized clinical trial was performed from September 2013 to August 2016 where closed or open diaphyseal or metaphyseo- diaphyseal fractures of the tibia (closed or open Gustilo Anderson type 1 through 3B) were included. Simple sequential allocation was used for allotting the patients to two groups, one for interlocking nailing and other for plating. The patients were followed up for clinical, radiographic and functional results. Forty patients with 41 involved limbs completed follow up for one year. The duration of surgery and average blood loss during surgery was 75.45±3.03 minutes and 165.00±5.31 ml respectively in case of nailing and 85.05±2.54 minutes and184.29±5.33 ml respectively in case of plating and their difference was statistically significant. In our study union was achieved in less than 20 weeks in 29 (70.8%) of the patients and 25-30 weeks in nine (22%) cases. The average time of union in our study was 19.55±0.69 weeks in case of interlocking nailing and 20.38±1.39 weeks in case of plating and there was no statistically significant difference between the two. However, there is statistically significant difference in the functional score in between the two groups in terms of Lower Extremity Functional Score (LEFS). Delayed union in one case of nailing and two cases of plating, valgus malunion in one case of nailing and joint stiffness in two cases each of nailing and plating were the major complications observed. There was no difference between the two modalities

  13. Interlocking Nailing Versus Plating in Tibial Shaft Fractures in Adults: A Comparative Study

    PubMed Central

    Arambam, Mahendra Singh; Waikhom, Sanjib; Santosha; Masatwar, Pranav Vitthal; Maske, Rohan Gautam

    2017-01-01

    Introduction Tibial diaphyseal fractures are the commonest long bone fractures in adults, most commonly managed by intramedullary interlocking nailing. However, several meta-analysis show that locking plate osteosynthesis is equally effective in managing tibial diaphyseal fractures and are associated with less number of complications. Aim To compare the results of fixation of tibial fractures following plating and nailing in terms of union, patient satisfaction and complications. Materials and Methods A hospital based non randomized clinical trial was performed from September 2013 to August 2016 where closed or open diaphyseal or metaphyseo- diaphyseal fractures of the tibia (closed or open Gustilo Anderson type 1 through 3B) were included. Simple sequential allocation was used for allotting the patients to two groups, one for interlocking nailing and other for plating. The patients were followed up for clinical, radiographic and functional results. Results Forty patients with 41 involved limbs completed follow up for one year. The duration of surgery and average blood loss during surgery was 75.45±3.03 minutes and 165.00±5.31 ml respectively in case of nailing and 85.05±2.54 minutes and184.29±5.33 ml respectively in case of plating and their difference was statistically significant. In our study union was achieved in less than 20 weeks in 29 (70.8%) of the patients and 25-30 weeks in nine (22%) cases. The average time of union in our study was 19.55±0.69 weeks in case of interlocking nailing and 20.38±1.39 weeks in case of plating and there was no statistically significant difference between the two. However, there is statistically significant difference in the functional score in between the two groups in terms of Lower Extremity Functional Score (LEFS). Delayed union in one case of nailing and two cases of plating, valgus malunion in one case of nailing and joint stiffness in two cases each of nailing and plating were the major complications observed

  14. The influence of distal locking on the need for fibular plating in intramedullary nailing of distal metaphyseal tibiofibular fractures.

    PubMed

    Attal, R; Maestri, V; Doshi, H K; Onder, U; Smekal, V; Blauth, M; Schmoelz, W

    2014-03-01

    Using human cadaver specimens, we investigated the role of supplementary fibular plating in the treatment of distal tibial fractures using an intramedullary nail. Fibular plating is thought to improve stability in these situations, but has been reported to have increased soft-tissue complications and to impair union of the fracture. We proposed that multidirectional locking screws provide adequate stability, making additional fibular plating unnecessary. A distal tibiofibular osteotomy model performed on matched fresh-frozen lower limb specimens was stabilised with reamed nails using conventional biplanar distal locking (CDL) or multidirectional distal locking (MDL) options with and without fibular plating. Rotational stiffness was assessed under a constant axial force of 150 N and a superimposed torque of ± 5 Nm. Total movement, and neutral zone and fracture gap movement were analysed. In the CDL group, fibular plating improved stiffness at the tibial fracture site, albeit to a small degree (p = 0.013). In the MDL group additional fibular plating did not increase the stiffness. The MDL nail without fibular plating was significantly more stable than the CDL nail with an additional fibular plate (p = 0.008). These findings suggest that additional fibular plating does not improve stability if a multidirectional distal locking intramedullary nail is used, and is therefore unnecessary if not needed to aid reduction.

  15. Augmentation plating in hypertrophic non-union after nail fixation of femoral shaft fracture compared with exchange plating.

    PubMed

    Jiang, Liangjun; Pan, Zhijun; Zheng, Qiang

    2014-01-01

    Augmentation plating has been used successfully to treat hypertrophic non-union after nail fixation. This study compared the efficacy of augmentation plating and exchange plating for treating hypertrophic non-union of femoral shaft fracture after intramedullary nail fixation. A total of 12 patients received augmentation plating and 15 patients received exchange plating as treatment for femoral shaft hypertrophic non-union. The procedures were conducted at our medical centre between January 2005 and January 2012. Clinical follow-up was conducted at 2 weeks, 1 month and then monthly until union was achieved to compare union time, operation time, bleeding and complications between the two groups. All patients underwent follow-up examinations until fracture union was achieved. The average length of follow-up time after the second treatment was (18.37 ± 3.28) months. The time needed for union was (4.17 ± 0.94) months in the augmentation plating group and (5.33 ± 1.72) months in the exchange plating group. The operation time was (90.00 ± 17.58) minutes in the augmentation plating group and (160.00 ± 25.35) minutes in the exchange plating group. The amount of blood loss during the operation was (270.00 ± 43.32) ml in the augmentation plating group and (530.00 ± 103.65) ml in the exchange plating group. Both groups showed significant difference (P < 0.05) in their results. No complications were reported after the second operation. Augmentation plating after nail fixation could remove local rotation instability, facilitate simple operation, create minimal damage and enable exercise for early functional recovery. Therefore, augmentation plating is excellent for treating hypertrophic non-union after nail fixation in femoral shaft fracture.

  16. Periarticular locking plate vs intramedullary nail for tibiotalocalcaneal arthrodesis: a biomechanical investigation.

    PubMed

    Ohlson, Blake L; Shatby, Meena W; Parks, Brent G; White, Kacey L; Schon, Lew C

    2011-02-01

    Augmented retrograde intramedullary (IM) nail fixation was compared with augmented periarticular locking- plate fixation for tibiotalocalcaneal arthrodesis. Specimens in 10 matched pairs were randomly assigned to a fixation construct and loaded cyclically in dorsiflexion. The groups did not differ in initial or final stiffness, load to failure, or construct deformation. No correlation was found between bone mineral density and construct deformation for either group. A humeral locking plate may be a viable alternative to an IM nail for tibiotalocalcaneal fixation in cases not amenable to IM nailing.

  17. Primary stability of an intramedullary calcaneal nail and an angular stable calcaneal plate in a biomechanical testing model of intraarticular calcaneal fracture.

    PubMed

    Goldzak, M; Simon, P; Mittlmeier, T; Chaussemier, M; Chiergatti, R

    2014-01-01

    intramedullary nail appeared to be superior to an angular stable plate representing the present standard technique in open reconstruction of the fractured calcaneus. The results from the experimental model speak in favour of the clinical use of the intramedullary calcaneal nail. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Comparison between locked intramedullary nailing and anatomical locking plating in the treatment of displaced clavicular midshaft fractures.

    PubMed

    Zehir, Sinan; Çalbıyık, Murat; Şahin, Ercan; İpek, Deniz

    2016-01-01

    The aim of this study was to compare the results of expandable flexible locked intramedullary nailing and anatomical locking plating in clavicular midshaft fractures. Thirty-three patients (21 male, 12 female) who had displaced fractures and at least 2-cm shortening fixed with expandable flexible locked intramedullary nailing and 38 patients (24 male, 14 female) who underwent anatomical locking plating were recruited. Duration of surgery, incision size, duration of hospital stay, union time, and early and late complications were compared between the groups. Functional results were compared with Constant scoring system. Mean duration of surgery was 32.4±9.1 minutes (range: 20-42 minutes) in the nailing group and 54.1±11.9 minutes (range: 42-70 minutes) in the plating group. The incision was 4.1±0.9 cm (range: 3-5 cm) in the nailing group and 9.5±1.7 cm (range: 7-12 cm) in the plating group. Mean union time was 14.8 weeks (range: 10-24 weeks) in the nailing group and 21.3 weeks (range: 12-33 weeks) in the plating group. Mean duration of hospital stay was 3.6±1.1 days (range: 2-4 days) in the plating group, whereas it was 2.3±0.8 days (range: 1-3 days) in the nailing group. In the plating group, an average of 2.7-mm (range: 0-7 mm) shortening was determined in the clavicles that underwent surgery as compared to the intact clavicles, whereas shortening was 2.3 mm (range: 0-6 mm) in the nailing group. Expandable flexible locked intramedullary nailing can provide more successful outcomes than plating in displaced clavicular midshaft fractures, due to advantages such as shorter union time, lower complication rate, and better cosmetic outcomes.

  19. Er:YLF-laser microperforation of the nail plate for drug delivery

    NASA Astrophysics Data System (ADS)

    Belikov, Andrey V.; Skrypnik, Alexei V.; Sergeev, Andrey N.; Smirnov, Sergey N.; Tavalinskaya, Anastasia D.

    2018-04-01

    Laser microperforation of a human nail plate is an effective method to increase the speed of local drugs delivery in the treatment of nail diseases. In this paper we present the study results of the influence of spatial parameters of Er:YLFlaser- produced microhole array in human nail plate (the diameter of microholes and their packing density) on the rate (vsp) of 0.25 % water-alcohol solution of methylene blue penetration through a single microhole and on the time (Tmp) required for uniform distribution of this drug under the nail plate. In experiments, the diameter of microholes was 220 +/- 10 μm, 300 +/- 10 μm or 350 +/- 10 μm. The packing density for microholes of each of these diameters was 100 μholes/cm2, 400 μholes/cm2 and 950 μholes/cm2. It is shown that vsp is mainly determined by the microhole diameter, and the packing density does not have a significant influence on it. It was experimentally established that the rate vsp is maximal for microholes with 350 μm diameter at packing density of 950 μholes/cm2 and reaches a value of 6.3 μm/s, and the time Tmp is minimal and equal to 180 +/- 10 s at the same values of microhole diameter and packing density.

  20. Intramedullary nailing versus plating for distal tibia fractures without articular involvement: a meta-analysis.

    PubMed

    Mao, Zhi; Wang, Guoqi; Zhang, Lihai; Zhang, Licheng; Chen, Shuo; Du, Hailong; Zhao, Yanpeng; Tang, Peifu

    2015-06-16

    The choice between intramedullary (IM) nailing or plating of distal tibia fractures without articular involvement remains controversial. A meta-analysis of randomized controlled trials (RCTs) and observational studies was performed to compare IM nailing with plating for distal tibia fractures without articular involvement and to determine the dominant strategy. The PubMed, Embase, Cochrane Library databases, Chinese Wan-Fang Database, and China National Knowledge Infrastructure were searched. Twenty-eight studies, which included 1863 fractures, met the eligible criteria. The meta-analysis did not identify a statistically significant difference between the two treatments in terms of the rate of deep infection, delayed union, removal of instrumentation, or secondary procedures either in the RCT or retrospective subgroups. IM nailing was associated with significantly more malunion events and a higher incidence of knee pain in the retrospective subgroup and across all the studies, but not significantly in the RCT subgroup, and a lower rate of delayed wound healing and superficial infection both in the RCT and retrospective subgroups relative to plating. A meta-analysis of the functional scores or questionnaires was not possible because of the considerable variation among the included studies, and no significant differences were observed. Evidence suggests that both IM nailing and plating are appropriate treatments as IM nailing shows lower rate of delayed wound healing and superficial infection and plating may avoid malunion and knee pain. These findings should be interpreted with caution, however, because of the heterogeneity of the study designs. Large, rigorous RCTs are required.

  1. Comparison of Posterior Approach With Intramedullary Nailing Versus Lateral Transfibular Approach With Fixed-Angle Plating for Tibiotalocalcaneal Arthrodesis.

    PubMed

    Mulligan, Ryan P; Adams, Samuel B; Easley, Mark E; DeOrio, James K; Nunley, James A

    2017-12-01

    A variety of operative approaches and fixation techniques have been described for tibiotalocalcaneal (TTC) arthrodesis. The intramedullary (IM) nail and lateral, fixed-angle plating are commonly used because of ease of use and favorable biomechanical properties. A lateral, transfibular (LTF) approach allows for direct access to the tibiotalar and subtalar joints, but the posterior, Achilles tendon-splitting (PATS) approach offers a robust soft tissue envelope. The purpose of this study was to compare the results of TTC arthrodesis with either a PATS approach with IM nailing or LTF approach with fixed-angle plating. A retrospective review was performed on all patients who underwent simultaneous TTC arthrodesis with minimum 1 year clinical and radiographic follow up. Patients were excluded if they underwent TTC arthrodesis through an approach other than PATS or LTF, and received fixation without an IM nail or fixed-angle plate. Primary outcomes examined were union rate, revisions, and complications. Thirty-eight patients underwent TTC arthrodesis with a PATS approach and IM nailing, and 28 with a LTF approach and lateral plating. The overall union rate was 71%; 76% (29 of 38 patients) for the PATS/IM nail group, and 64% (18 of 28) for LTF/plating group ( P = .41). Symptomatic nonunion requiring revision arthrodesis occurred in 16% (6 of 38) of the PATS/IM nail group versus 7% (2 of 28) in the LTF/lateral plating group ( P = .45). There were no significant differences in individual tibiotalar or subtalar union rates, superficial wound problems, infection, symptomatic hardware, stress fractures, or nerve irritations. Union, revision, and complication rates were similar for TTC arthrodesis performed with a PATS approach and IM nail compared with an LTF approach and fixed-angle plate in a complex patient population. Both techniques were adequate, especially when prior incisions, preexisting hardware, or deformity preclude options. Level III, retrospective comparative

  2. [Treatment of clavicular fractures using intramedullary nailing or K-wire versus plating fixation: a meta-analysis].

    PubMed

    Zhang, Ke-xue; Zhao, Jing-xin; Zhao, Zhe; Ng, Li-cheng; Su, Xiu-yun; Long, An-hua; Mao, Zhi; Zhang, Jin-hui; Zhang, Li-hai; Tang, Pei-fu

    2015-05-01

    TFo compare the efficacy and complications rate of intramedullary (IM) nailing or K-wire versus plating fixation for clavicular fractures. Pubmed, Embase, Cochrane Library databases, CNKI, VIP and Wangfang databases were searched to find all randomized or quasi-randomized controlled trials of clavicle fractures using plating versus IM nailing or K-wire. The methodologic quality of the studies was assessed. After independent study selection by 2 authors ,data were collected and extracted independently. Outcomes of postoperative shoulder functional measurement, the efficacy and information of the operation and complications rate were meta-analyzed using RevMan 5 software. Nine hundreds and seventy-six patients in 10 randomized controlled trials (RCTs) and 3 quasi-RCTs were involved in the meta-analysis,of which 5 studies compared the K-wire and the plating fixations and 8 studies compared the IM nailing and the plating fixations. The overall odds ratio(OR) (with 95% CI) of the operation efficacy for K-wire versus the plating was 3.79 (1.93, 7.46). The overall weighted mean difference (with 95% CI) of Constant Shoulder score for plating versus IM fixation was -1.39 (-3.43, 0.65) in 6 studies. The overall OR of the plating versus IM nailing was 9.34(2.70, 32.32) for the overall major complications in 5 studies and 5.04 (1.52,16.77) for the revision rate in 5 studies. The current limited evidences suggested that the IM fixation could reduce the incidences of the overall major complications and the revision surgery, while the post-operative efficacy of the plating was superior to the K-wire. More high quality RCTs are still needed in the future.

  3. Intramedullary nailing for the treatment of aseptic femoral shaft non-unions after plating failure: effectiveness and timing.

    PubMed

    Megas, Panagiotis; Syggelos, Spyros A; Kontakis, Georgios; Giannakopoulos, Andreas; Skouteris, Georgios; Lambiris, Elias; Panagiotopoulos, Elias

    2009-07-01

    This retrospective, multicentre study aimed to evaluate reamed intramedullary nailing (IMN) for the treatment of 30 cases of aseptic femoral shaft non-union after plating failure. Following nailing, 29 non-unions had healed by a mean 7.93 months. In one case a hypertrophic non-union required renailing after 8 months, using a nail of greater diameter, and united within five further months. Healing times were not related to whether the fracture was open or closed, the type non-union or the type of fracture. The delay from the initial plating to intramedullary nailing had a statistically significant effect on healing time and final outcome. This treatment is cost effective and should be implemented as soon as the non-union is diagnosed.

  4. [Comparison of mid-term surgical results between plate and intramedullary nail for humeral shaft fracture].

    PubMed

    Zhao, G; Liu, H N; Li, N; He, L; Wu, X B

    2016-10-11

    Objective: To evaluate the mid-term clinical efficacy of plate and intramedullary nail for humeral shaft fracture. Methods: In this retrospective study a total of 122 patients with humeral shaft fracture were divided into 2 groups according to surgery type from May 2010 to July 2012. There were 63 patients in plate group and 59 patients in intramedullary nail group. The factors related to the operation for each group were compared respectively. The clinical outcome was evaluated by the Neer scores, Myao scores and EuroQol 5 dimensions scores (EQ-5D). All the patients were followed up periodically in the next 3 years. Results: There were no significant differences between the two groups on hospital stay and time of returning to work ( P >0.05). While the operation time, amount of intraoperative blood loss and complication rate were less in intramedullary nail group. The mean follow-up duration was (41.2±4.2) months in plate group and (42.1±4.7) months in intramedullary nail group respectively. At the last follow-up the postoperative Neer scores, Myao scores and EQ-5D scores showed no significant differences between the 2 groups[Neer: (93.8±6.1) vs(92.1±4.2); Myao: (94.9±2.9) vs(96.2±1.5), P >0.05]. There were no cases complicated with nonunion, delayed union, infection and deformity during the follow-up period. Conclusions: The mid-term outcome of open reduction and internal fixation with plate and close reduction with intramedullary nail for humeral shaft fracture is satisfactory. Although both surgeries are safe and effective, they also have some defaults. The doctors should choose the right surgery carefully according to the actual situation of the patients.

  5. Finite element analysis of locking plate and two types of intramedullary nails for treating mid-shaft clavicle fractures.

    PubMed

    Ni, Ming; Niu, Wenxin; Wong, Duo Wai-Chi; Zeng, Wei; Mei, Jiong; Zhang, Ming

    2016-08-01

    Both plate and intramedullary nail fixations, including straight and anatomic nails, have been clinically adopted for the treatment of displaced mid-shaft clavicle fractures. However, the biomechanical performances of these fixations and implants have not been well evaluated. This study aims to compare the construct stability, stress distribution and fracture micro-motion of three fixations based on finite element (FE) method. The FE model of clavicle was reconstructed from CT images of a male volunteer. A mid-shaft fracture gap was created in the intact clavicle. Three fixation styles were simulated including locking plate (LP), anatomic intramedullary nail (CRx), and straight intramedullary nail (RCP). Two loading scenarios (axial compression and inferior bending) were applied at the distal end of the clavicle to simulate arm abduction, while the sternal end was fixed. Under both conditions, the LP was the stiffest, followed by the CRx, and the RCP was the weakest. LP also displayed a more evenly stress distribution for both implant and bone. RCP had a higher stress compared with CRx in both conditions. Moreover, all implants sustained higher stress level under the loading condition of bending than compression. The plate fixation significantly stabilizes the fracture gap, reduces the implant stress, and serves as the recommended fixation for the mid-shaft clavicle fracture. The CRx is an alternative device to treat clavicle shaft fracture, but the shoulder excessive activities should be avoided after operation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Physics of nail conditions: why do ingrown nails always happen in the big toes?

    PubMed

    Rauch, Cyril; Cherkaoui-Rbati, Mohammed

    2014-10-16

    Although surgical treatment of nail conditions can be traced back centuries to the writings of Paul Aegineta (625-690 AC), little is known about the physical laws governing nail growth. Such a poor understanding together with the increasing number of nail salons in the high street should raise legitimate concerns regarding the different procedures applied to nails. An understanding of the physics of nail growth is therefore essential to engage with human medicine and to understand the aetiology of nail conditions. In this context, a theory of nail plate adhesion, including a physical description of nail growth can be used to determine the transverse and longitudinal curvatures of the nail plate that are so important in the physical diagnosis of some nail conditions. As a result physics sheds light on: (a) why/how nails/hooves adhere strongly, yet grow smoothly; (b) why hoof/claw/nail growth rates are similar across species; (c) potential nail damage incurred by poor trimming; (d) the connection between three previously unrelated nail conditions, i.e. spoon-shaped, pincer and ingrown nails and; last but not least, (e) why ingrown nails occur preferentially in the big toes.

  7. Longitudinal erythronychia: individual or multiple linear red bands of the nail plate: a review of clinical features and associated conditions.

    PubMed

    Cohen, Philip R

    2011-08-01

    Longitudinal erythronychia is a linear red band on the nail plate that originates at the proximal nail fold, traverses the lunula, and extends to the free edge of the nail plate. Longitudinal erythronychia is classified based upon the number of nails affected and the number of red streaks present on each nail as follows: type Ia (monodactylous - single band), type Ib (monodactylous - bifid bands), type IIa (polydactylous - single band), and type IIb (polydactylous - multiple bands). Associated morphologic findings that can be present at the distal tip of the nail with longitudinal erythronychia include fragility, onycholysis, splinter hemorrhage, splitting, subungual keratosis, thinning, and V-shaped nick. Some patients with longitudinal erythronychia seek medical evaluation because of pain in the associated distal digit; however, the linear red nail plate dyschromia is often asymptomatic and the individual is concerned about the cosmetic appearance or distal nail fragility. Longitudinal erythronychia can be a clinical manifestation of an underlying local or systemic condition. Benign tumors (glomus tumor, onychopapilloma, and warty dyskeratoma), malignant neoplasms (malignant melanoma and squamous cell carcinoma), and other conditions (hemiplegia and postsurgical scar) can be associated with monodactylous longitudinal erythronychia or it may be idiopathic or the initial stage of polydactylous longitudinal erythronychia-associated systemic conditions. Polydactylous longitudinal erythronychia is most commonly reported in patients with Darier disease (keratosis follicularis); other associated conditions include acantholytic dyskeratotic epidermal nevus, acantholytic epidermolysis bullosa, acrokeratosis verruciformis of Hopf, amyloidosis, graft-versus-host disease, lichen planus, and pseudobulbar syndrome. Polydactylous longitudinal erythronychia has also been observed as an idiopathic finding. Biopsy of the nail matrix and nail bed may be necessary to establish the

  8. A prospective, randomised trial comparing closed intramedullary nailing with percutaneous plating in the treatment of distal metaphyseal fractures of the tibia.

    PubMed

    Guo, J J; Tang, N; Yang, H L; Tang, T S

    2010-07-01

    We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients' age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware. We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p < 0.001, and 97.9 vs 81.2 minutes, p < 0.001, respectively).After one year, all the fractures had united. Patients who had intramedullary nailing had a higher mean pain score (40 = no pain, 0 = severe pain), [corrected] but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed. We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal

  9. Effectiveness of exchange K-nail and augmented plating in aseptic femoral diaphyseal non-union.

    PubMed

    Sancheti, K H; Pradhan, Chetan; Patil, Atul; Puram, Chetan; Bharti, Parkalp; Sancheti, Parag; Shyam, Ashok

    2017-08-01

    Femoral diaphyseal non-unions present difficult scenario to manage. There are multiple options but most of them still report varying incidences of failure. We combined the principles of augmented plating and exchange nailing and aim to study the effectiveness of this technique. A retrospective study at a tertiary trauma centre was conducted. Seventy patients (60 men, 10 women), average age 40.7±15.27 years (range 18-81 years) with diaphyseal femoral fracture non-unions treated between July 2010 and January 2015 were reviewed. The average interval between first and the last surgery was 18.07±17.65 months (range 4-96 months). Forty six patients had hypertrophic non-union and 24 patients had atrophic non-union. Twenty one patients had undergone a prior surgery for non-union, 13 dynamisation, 4 bone grafting, 1 augmented plating and 3 exchange nailing. Non-unions were treated with implant removal, freshening of bone edges and exchange K-nailing and augmented plating. Autologous bone grafting and raising of osteoperiosteal flaps was done in all cases. Outcome measures were radiographic evidence of fracture union at minimum three out of four cortices, knee range of motion as compared to opposite knee, and study of complications. All patients demonstrated radiographic evidence of fracture union with an average time of 16.77±2.38 weeks (range 12-26 weeks). Mean knee range of motion of unaffected limb was 126±9.76° (range 90-140°) while in operated limb it was 121.1±11.36° (range 80-140°), p>0.01. Patients with hypertrophic non-unions, prior surgery for non-union and supra- or infra-isthmal non-unions had shorter union time. Two patients had superficial infection which was managed by superficial debridement and two patients had pain at proximal nail tip site which was managed by anti-inflammatory medication. None of the patients required additional surgery for implant removal. Exchange K nailing with Bone graft and additional plating technique for non

  10. Intramedullary nail fixation versus locking plate fixation for adults with a fracture of the distal tibia: the UK FixDT RCT.

    PubMed

    Costa, Matthew L; Achten, Juul; Hennings, Susie; Boota, Nafisa; Griffin, James; Petrou, Stavros; Maredza, Mandy; Dritsaki, Melina; Wood, Thomas; Masters, James; Pallister, Ian; Lamb, Sarah E; Parsons, Nick R

    2018-05-01

    The best treatment for fractures of the distal tibia remains controversial. Most of these fractures require surgical fixation, but the outcomes are unpredictable and complications are common. To assess disability, quality of life, complications and resource use in patients treated with intramedullary (IM) nail fixation versus locking plate fixation in the 12 months following a fracture of the distal tibia. This was a multicentre randomised trial. The trial was conducted in 28 UK acute trauma centres from April 2013 to final follow-up in February 2017. In total, 321 adult patients were recruited. Participants were excluded if they had open fractures, fractures involving the ankle joint, contraindication to nailing or inability to complete questionnaires. IM nail fixation ( n  = 161), in which a metal rod is inserted into the hollow centre of the tibia, versus locking plate fixation ( n  = 160), in which a plate is attached to the surface of the tibia with fixed-angle screws. The primary outcome measure was the Disability Rating Index (DRI) score, which ranges from 0 points (no disability) to 100 points (complete disability), at 6 months with a minimum clinically important difference of 8 points. The DRI score was also collected at 3 and 12 months. The secondary outcomes were the Olerud-Molander Ankle Score (OMAS), quality of life as measured using EuroQol-5 Dimensions (EQ-5D), complications such as infection, and further surgery. Resource use was collected to inform the health economic evaluation. Participants had a mean age of 45 years (standard deviation 16.2 years), were predominantly male (61%, 197/321) and had experienced traumatic injury after a fall (69%, 223/321). There was no statistically significant difference in DRI score at 6 months [IM nail fixation group, mean 29.8 points, 95% confidence interval (CI) 26.1 to 33.7 points; locking plate group, mean 33.8 points, 95% CI 29.7 to 37.9 points; adjusted difference, 4.0 points, 95% CI -1.0 to 9

  11. Comparison of the antifungal efficacy of terbinafine hydrochloride and ciclopirox olamine containing formulations against the dermatophyte Trichophyton rubrum in an infected nail plate model.

    PubMed

    Täuber, Anja; Müller-Goymann, Christel C

    2014-07-07

    Onychomycosis is a fungal infection mostly induced by dermatophytes such as Trichophyton rubrum. Due to slow nail growth, the treatment takes 3-9 months depending on the nail size and infected area. Hence, high efficacy of the active ingredient without systemic side effects is of major interest. To test the efficacy of an antifungal formulation, an appropriate in vitro model reflecting the in vivo situation as close as possible is required. In this study, a variety of antifungal formulations, i.e., commercial ones (Ciclopoli and Lamisil cream), those used in compounding pharmacies (Pentravan) as well as poloxamer 407-based systems, have been evaluated in an infected nail plate model. The active pharmaceutical ingredients (APIs) were ciclopirox olamine and terbinafine hydrochloride. The poloxamer 407-based formulations consisted of poloxamer 407, double distilled water, propylene glycol, isopropyl alcohol, medium chain triglycerides and either 1% ciclopirox olamine or 1% terbinafine hydrochloride as API, respectively. Former studies have shown high permeation rates of terbinafine hydrochloride from similar poloxamer 407-based formulations with dimethyl isosorbide instead of propylene glycol. The present contribution shows superior inhibition of T. rubrum growth from poloxamer 407-based formulations in comparison to the commercial Lamisil cream. Moreover, poloxamer 407-based formulations were equally effective as the nail lacquer Ciclopoli even though the poloxamer formulations contained only 1% of the drug instead of 8% in the marketed lacquer. Poloxamer 407-based systems containing ciclopirox olamine proved to be about as effective as similar terbinafine hydrochloride systems.

  12. Fixation of 4-part fractures of the proximal humerus: Can we identify radiological criteria that support locking plates or IM nailing? Comparative, retrospective study of 107 cases.

    PubMed

    Gadea, F; Favard, L; Boileau, P; Cuny, C; d'Ollone, T; Saragaglia, D; Sirveaux, F

    2016-12-01

    No objective criteria exist to help surgeons choose between IM nailing and plate fixation for 4-part fractures of the proximal humerus. The goal of this study was to identify radiological criteria that would make one technique a better choice than the other. This was a comparative, multicentre, retrospective study of 54 cases of antegrade nailing and 53 cases of plating performed between 1st January 2009 and 31 December 2011 for 4-part fractures of the proximal humerus. All patients had a minimum radiological and clinical follow-up of 18 months. The functional outcomes were evaluated using the weighted Constant score; a poor result was defined as a weighted Constant score<70%. The following radiological criteria were evaluated during the preoperative assessment and at the last follow-up: initial displacement and reduction of humeral head and tuberosities; morphology of the medial column (i.e. calcar comminution, posteromedial hinge, size of metaphyseal head extension); occurrence of avascular necrosis (AVN). After an average follow-up of 42 months, the weighted Constant scores and rate of poor outcomes were 77% and 48% in the nail group and 81% and 38% in the plate group, respectively (ns). The humeral head was reduced into an anatomical position, valgus or varus in 57%, 30% and 13% of cases in the nail group, and 58%, 29% and 13% in the plate group, respectively. The tuberosities healed in an anatomical position in 72% of nail cases and 70% of plate cases (ns). Only the presence of a medial hinge preoperatively had an effect on the functional outcomes in the nail and plate groups: the weighted Constant scores (P=0.05) and rate of poor outcomes (P=0.02) were 82% and 52% in the nail group and 97% and 9% in the plate group, respectively. The complication rates were comparable: the rates of AVN and articular screw penetration were 17% and 11% in the nail group, and 15% and 11% in the plate group, respectively. The surgical revision rate was 18.5% in the nail group and

  13. Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.

    PubMed

    Paulsson, Johnny; Stig, Josefine Corin; Olsson, Ola

    2017-08-24

    In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the respective treatment protocol, whereas one treatment protocol (Medoff sliding plate/dynamic hip screw) uses biaxial Medoff sliding plate for unstable pertrochanteric fractures and uniaxial Medoff sliding plate for subtrochanteric fractures, the second (intramedullary nail/dynamic hip screw) uses intramedullary nail for subtrochanteric fractures and for pertrochanteric fractures with intertrochanteric comminution or subtrochanteric extension. All orthopedic surgeries are registered in a regional database. All consecutive trochanteric fracture operations during 2011-2012 (n = 856) and subsequent technical reoperations (n = 40) were derived from the database. Reoperations were analysed and classified into the categories adjustment (percutaneous removal of the locking screw of the Medoff sliding plate or the intramedullary nail, followed by fracture healing) or minor, intermediate (reosteosynthesis) or major (hip joint replacement, Girdlestone or persistent nonunion) technical complications. The relative risk of intermediate or major technical complications was 4.2 (1.2-14) times higher in unstable pertrochanteric fractures and 4.6 (1.1-19) times higher in subtrochanteric fractures with treatment protocol: intramedullary nail/dynamic hip screw, compared to treatment protocol: Medoff sliding plate/dynamic hip screw. Overall rates of intermediate and major technical complications in unstable pertrochanteric and subtrochanteric fractures were with biaxial Medoff sliding plate 0.68%, with uniaxial Medoff sliding plate 1.4%, with dynamic hip screw 3.4% and with intramedullary nail 7.2%. The

  14. The clinical application of absorbable intramedullary nail and claw plate on treating multiple rib fractures.

    PubMed

    Chai, X; Lin, Q; Ruan, Z; Zheng, J; Zhou, J; Zhang, J

    2013-08-01

    The absorption intramedullary nail and claw plate indications and efficacy were investigated in the treatment of a life-threatening multiple rib fractures. A retrospective analysis of 248 surgically treated rib fracture patients was performed who admitted to our hospital from March 2007 to December 2012. Intramedullary nailing was performed in 28 cases, a claw-type bone plate was fixed in 141 cases, and a combination of both was fixed in 79 cases. All internal fixation patients were clinically cured except 1 patient died 14 days after a massive pulmonary embolism. The patients with flail chest and floating chest wall causing respiratory and circulatory disorders were promptly corrected. Routine follow-up was from 1 to 2 years, displaced fractures were in 2 cases, and there were 11 cases of internal fixation and extraction. Internal fixation is a simple and reliable method for the treatment of multiple rib fractures. Both internal fixation materials have their pros and cons but the claw bone plate is more robust. The actual selection of appropriate treatment options helps to improve the treatment efficacy.

  15. Diaphyseal Fractures of the Forearm in Adults, Plating Or Intramedullary Nailing Is a Better Option for the Treatment?

    PubMed Central

    Al-Sadek, Tabet A.; Niklev, Desislav; Al-Sadek, Ahmed

    2016-01-01

    BACKGROUND: Fractures of the radius and ulna occupy a large field of the modern traumatology. Therefore, these fractures are a major subject in modern orthopaedics and traumatology. The study of the mechanisms of the trauma, and the pathophysiological changes that occur are of great importance for the development of ever more efficient and varied ways of the treatment and prophylactics of this type of fracture. AIM: The aim of this paper was to study the pattern of the diaphyseal fractures of the forearm in adults, to decide the modalities of surgical management, to observe the period of fracture healing clinically and radiologically, as well to study the rehabilitation of the patients. MATERIAL AND METHODS: The present study included 45 cases of diaphyseal fractures of both bones forearm in adults presenting to the orthopaedic outpatient department. For all the patients a detailed history was taken. A thorough clinical examination was carried out, required X-rays were taken, and initial treatment was given and admitted as in all patients. After careful pre-operative planning and evaluation for anaesthetic fitness, patients were operated for the fractures of both bone forearms. Twenty-three cases with 46 fractures were treated by open reduction and rigid fixation with DCP & Semi-tubular plates and 22 cases with 44 fractures were treated by closed reduction and fixation with “Talwarkar” intramedullary square nails. RESULTS: United results were found in 100% of plating group vs. 86% in the nailing group. Delayed and non-union results were found in 9% of the nailing group only. Average time to union in weeks was 9.4 weeks in the plating group vs. 10.2 weeks in the nailing group. CONCLUSION: Open reduction and internal fixation with compression plates with strict adherence to surgical technique is the gold standard method of treatment in both bones forearm fractures with excellent results than closed reduction, internal fixation with “Talwarkar” square nails

  16. [Locked plating with minimally invasive percutaneous plate osteosynthesis versus intramedullary nailing of distal extra-articular tibial fracture: a retrospective study].

    PubMed

    Yao, Qi; Ni, Jie; Peng, Li-bin; Yu, Da-xin; Yuan, Xiao-ming

    2013-12-17

    To compare the efficacies of minimally invasive plate osteosynthesis (MIPPO) and interlocking intramedullary nailing (IMN) in the treatment of extra-articular fractures of distal tibia. Retrospective reviews were conducted for 126 patients with extra-articular distal tibia fractures. Treatment was either MIPPO (n = 61) or IMN (n = 65). The outcomes were assessed by comparing operating duration, time to union, the last follow-up American Orthopedic Foot and Ankle Society (AOFAS) score and complication rate. The average follow-up period was 23.7 (12-53) months. In the minimally invasive plate osteosynthesis group, there were deep infections (n = 2), superficial infections (n = 5), delayed union (n = 2), malunion (n = 2) and knee joint pain (n = 10) were observed. In addition, the average operating duration (85.9 ± 18.9 min), average time to union (17.3 ± 3.8 weeks) and average AOFAS (83.2 ± 11.9) were analyzed. In the interlocking intramedullary nailing group, there were delayed union (n = 3), malunion (n = 12) and knee joint pain (n = 22). And the average operating duration (83.3 ± 15.7 min), average time to union (16.5 ± 3.1 weeks) and average AOFAS (84.9 ± 12.0) were analyzed. No statistical significance existed in operating duration, time to union and the last follow-up AOFAS between two groups (P > 0.05). However, the rates of malformation and knee joint pain were higher in the intramedullary nail group than those in the plate group. And the difference was statistically significant (P = 0.015, P = 0.025). Both MIPPO and IMN are effective for extra-articular fractures of distal tibia. However, the former has the advantage of lowers rate of malformation and knee joint pain. Therefore a surgeon should consider the degree of injury while managing extra-articular fracture of distal tibia.

  17. Intramedullary nailing of humeral shaft fractures.

    PubMed

    Pickering, Robert M; Crenshaw, Andrew H; Zinar, Daniel M

    2002-01-01

    The development of interlocking humeral nail systems has greatly broadened the indications for nailing of humeral shaft fracture. Rotational control is better than with earlier nail systems, and most nails have an oblong distal hole that allows axial loading of the fracture site with muscle contraction. When nailing is done with closed technique, loss of the fracture hematoma and periosteal stripping are avoided. Even when open reduction is required, periosteal stripping can be kept to a minimum. Surgical wounds are smaller, even when open reduction is necessary, and when closed nailing is done, bone grafting is unnecessary. Intramedullary nails are ideal for segmental fractures, pathologic fractures, and fractures in osteopenic bone. Because the arm usually is not a weight-bearing extremity, hardware failure is rare and union rates are equivalent to those of compression plate and screw fixation. Compression plates and external fixation certainly have their place for some fracture patterns and for severe wounds that are unsuitable for intramedullary nailing. The surgeon should be well versed in all three techniques and should be able to rapidly choose among these, depending upon the fracture pattern, skin wound, associated injuries, and overall condition of the patient.

  18. Titanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study

    PubMed Central

    Liu, Yanjie; Zhang, Wen; Pan, Yao; Zhang, Wei; Zhang, Changqing; Zeng, Bingfang; Chen, Yunfeng

    2015-01-01

    Background The biomechanical characteristics of midshaft clavicular fractures treated with titanium elastic nail (TEN) is unclear. This study aimed to present a biomechanical finite element analysis of biomechanical characteristics involved in TEN fixation and reconstruction plate fixation for midshaft clavicular fractures. Methods Finite element models of the intact clavicle and of midshaft clavicular fractures fixed with TEN and with a reconstruction plate were built. The distal clavicle displacement, peak stress, and stress distribution on the 3 finite element models were calculated under the axial compression and cantilever bending. Results In both loading configurations, TEN generated the highest displacement of the distal clavicle, followed by the intact clavicle and the reconstruction plate. TEN showed higher peak bone and implant stresses, and is more likely to fail in both loading configurations compared with the reconstruction plate. TEN led to a stress distribution similar to that of the intact clavicle in both loading configurations, whereas the stress distribution with the reconstruction plate was nonphysiological in cantilever bending. Conclusions TEN is generally preferable for treating simple displaced fractures of the midshaft clavicle, because it showed a stress distribution similar to the intact clavicle. However, TEN provides less stability, and excessive exercise of and weight bearing on the ipsilateral shoulder should be avoided in the early postoperative period. Fixation with a reconstruction plate was more stable but showed obvious stress shielding. Therefore, for patients with a demand for early return to activity, reconstruction plate fixation may be preferred. PMID:25965409

  19. A comparative study of intramedullary interlocking nailing and minimally invasive plate osteosynthesis in extra articular distal tibial fractures.

    PubMed

    Daolagupu, Arup K; Mudgal, Ashwani; Agarwala, Vikash; Dutta, Kaushik K

    2017-01-01

    Extraarticular distal tibial fractures are among the most challenging fractures encountered by an orthopedician for treatment because of its subcutaneous location, poor blood supply and decreased muscular cover anteriorly, complications such as delayed union, nonunion, wound infection, and wound dehiscence are often seen as a great challenge to the surgeon. Minimally invasive plate osteosynthesis (MIPO) and intramedullary interlocking nail (IMLN) are two well-accepted and effective methods, but each has been historically related to complications. This study compares clinical and radiological outcome in extraarticular distal tibia fractures treated by intramedullary interlocking nail (IMLN) and minimally invasive plate osteosynthesis (MIPO). 42 patients included in this study, 21 underwent IMLN and 21 were treated with MIPO who met the inclusion criteria and operated between June 2014 and May 2015. Patients were followed up for clinical and radiological evaluation. In IMLN group, average union time was 18.26 weeks compared to 21.70 weeks in plating group which was significant ( P < 0.0001). Average time required for partial and full weight bearing in the nailing group was 4.95 weeks and 10.09 weeks respectively which was significantly less ( P < 0.0001) as compared to 6.90 weeks and 13.38 weeks in the plating group. Lesser complications in terms of implant irritation, ankle stiffness, and infection, were seen in interlocking group as compared to plating group. Average functional outcome according to American Orthopedic Foot and Ankle Society score was measured which came out to be 96.67. IMLN group was associated with lesser duration of surgery, earlier weight bearing and union rate, lesser incidence of infection and implant irritation which makes it a preferable choice for fixation of extra-articular distal tibial fractures. However, larger randomized controlled trials are required for confirming the results.

  20. Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures.

    PubMed

    Chen, Fancheng; Huang, Xiaowei; Ya, Yingsun; Ma, Fenfen; Qian, Zhi; Shi, Jifei; Guo, Shuolei; Yu, Baoqing

    2018-01-16

    Proximal tibia fractures are one of the most familiar fractures. Surgical approaches are usually needed for anatomical reduction. However, no single treatment method has been widely established as the standard care. Our present study aims to compare the stress and stability of intramedullary nails (IMN) fixation and double locking plate (DLP) fixation in the treatment of extra-articular proximal tibial fractures. A three-dimensional (3D) finite element model of the extra-articular proximal tibial fracture, whose 2-cm bone gap began 7 cm from the tibial plateau articular surface, was created fixed by different fixation implants. The axial compressive load on an adult knee during single-limb stance was imitated by an axial force of 2500 N with a distribution of 60% to the medial compartment, while the distal end was fixed effectively. The equivalent von Mises stress and displacement of the model was used as the output measures for analysis. The maximal equivalent von Mises stress value of the system in the IMN model was 293.23 MPa, which was higher comparing against that in the DLP fixation model (147.04 MPa). And the mean stress of the model in the IMN model (9.25 MPa) was higher than that of the DLP fixation system in terms of equivalent von Mises stress (EVMS) (P < 0.0001). The maximal value of displacement (sum) in the IMN system was 8.82 mm, which was lower than that in the DLP fixation system (9.48 mm). This study demonstrated that the stability provided by the locking plate fixation system was superior to the intramedullary nails fixation system and served as an alternative fixation for the extra-articular proximal tibial fractures of young patients.

  1. Dermoscopy in the Evaluation of Nail Disorders

    PubMed Central

    Alessandrini, Aurora; Starace, Michela; Piraccini, Bianca Maria

    2017-01-01

    Nail dermoscopy was initially used only in the assessment of nail pigmentation, but now it is widely utilized for the evaluation of many nail disorders. In daily practice, dermoscopy may confirm clinical diagnoses and guides in the management of nail diseases and treatments, permitting a better visualization of symptoms. Dry dermoscopy is required for evaluation of the nail plate surface, while gel as an interface is necessary for assessment of nail pigmentation and onycholysis, as well as for the evaluation of the distal nail margin. In this review, we describe the dermoscopic features of the most important nail disorders, looking at the different areas of the nail. Dermatoscopic changes that usually accompany specific nail diseases are also reviewed. PMID:28560217

  2. Comparative investigation of percutaneous plating and intramedullary nailing effects on IL-6 production in patients with tibia shaft fracture.

    PubMed

    Ebrahimpour, Adel; Okhovatpour, Mohammad-Ali; Sadighi, Mehrdad; Sarejloo, Amir-Hossein; Sajjadi, Mohammad-Reza Minator

    2017-12-01

    The aim of this study was to analyze the effect of intramedullary nailing (IMN), open plating and percutaneous plating on the induction of IL-6 in patients with tibia fractures. A total of 30 patients with tibia shaft fracture underwent either intramedullary nailing (IMN, n = 15; 14 males and 1 female; mean age: 32.1 ± 15.6), ORIF plating (n = 8; 5 males and 3 females; mean age: 60.0 ± 17.8), or percutaneous plating (n = 7; 6 males and 1 female; mean age: 43.1 ± 21.4). Serum IL-6 cytokine levels were measured prior to, and 6 and 24 h after the surgery, using a special ELISA kit. The IL-6 concentration increased to peak levels at 6 h in both IMN and percutaneous plating groups, and at 24 h in ORIF plating group (p < 0.001). The mean IL-6 concentration of percutaneous plating group was significantly lower than that of the IMN group at 6 h following the surgery (p = 0.022). In addition, the mean IL-6 concentration of ORIF plating group was significantly higher than that of the percutaneous plating group at 24 h post operation (p = 0.009). Our results suggest that percutaneous plating compared to the IMN has lower effects on IL-6 production in patients with tibia fracture. Level III, therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  3. Plate fixation versus intramedullary nailing of completely displaced midshaft fractures of the clavicle: a prospective randomised controlled trial.

    PubMed

    Fuglesang, H F S; Flugsrud, G B; Randsborg, P H; Oord, P; Benth, J Š; Utvåg, S E

    2017-08-01

    This is a prospective randomised controlled trial comparing the functional outcomes of plate fixation and elastic stable intramedullary nailing (ESIN) of completely displaced mid-shaft fractures of the clavicle in the active adult population. We prospectively recruited 123 patients and randomised them to either plate fixation or ESIN. Patients completed the Quick Disabilities of the Arm, Shoulder and Hand (DASH) score at one to six weeks post-operatively. They were followed up at six weeks, three and six months and one year with radiographs, and their clinical outcome was assessed using both the DASH and the Constant Score. Plate fixation provided a faster functional recovery during the first six months compared with ESIN, but there was no difference after one year. The duration of surgery was shorter for ESIN (mean 53.4 minutes, 22 to 120) than for plate fixation (mean 69.7 minutes, 35 to 106, p < 0.001). The recovery after ESIN was slower with increasing fracture comminution and with open reduction (p < 0.05). Both methods return the patients to their pre-injury functional levels, but plate fixation has a faster recovery period in comminuted fractures than ESIN. ESIN has a shorter operative time and lower infection and implant rates of failure when using 2.5 mm nails or wider, suggesting that this is the preferred method in mid-shaft fractures with no comminution, whereas plate fixation is the superior method in comminuted fractures. Cite this article: Bone Joint J 2017;99-B:1095-1101. ©2017 The British Editorial Society of Bone & Joint Surgery.

  4. Onychopharmacokinetics of terbinafine hydrochloride penetration from a novel topical formulation into the human nail in vitro.

    PubMed

    Hui, Xiaoying; Lindahl, Åke; Lamel, Sonia; Maibach, Howard I

    2013-09-01

    This study determined the onychopharmacokinetics, nail absorption, distribution, and penetration of [¹⁴C]-terbinafine HCl in a new topical formulation into/through the human finger nail using the in vitro finite dose model. This study determined the penetration rate of terbinafine HCl from multiple doses of topical formulation applied daily for 14 days. Results showed that the total dose recovery (mass balance) was almost 100%. The concentration of terbinafine HCl in the deeper nail plate (ventral/intermediate layers) and the cotton-pad nail bed samples after the 14-day treatment were 613 ± 145 and (±S.D.) and 27 ± 1.2 µg/cm³ (or 1.9 ± 0.6 µg/cm³ daily) on average, respectively. In comparison with nail concentration data from the literature for other topical terbinatine formulations, our results show that higher amounts of terbinafine HCl reached the deep nail plate and/or the nail bed after a 14-day topical treatment with this topical formulation in vitro.

  5. Heat profiles of laser-irradiated nails

    NASA Astrophysics Data System (ADS)

    Paasch, Uwe; Nenoff, Pietro; Seitz, Anna-Theresa; Wagner, Justinus A.; Kendler, Michael; Simon, Jan C.; Grunewald, Sonja

    2014-01-01

    Onychomycosis is a worldwide problem with no tendency for self-healing, and existing systemic treatments achieve disease-free nails in only 35 to 76% of cases. Recently, treatment of nail fungus with a near-infrared laser has been introduced. It is assumed that fungal eradication is mediated by local heat. To investigate if laser treatment has the potential to eradicate fungal hyphae and arthrospores, laser heat application and propagation needs to be studied in detail. This study aimed to measure nail temperatures using real-time videothermography during laser irradiation. Treatment was performed using 808- and 980-nm linear scanning diode lasers developed for hair removal, enabling contact-free homogeneous irradiation of a human nail plate in one pass. Average and peak temperatures increased pass by pass, while the laser beam moved along the nail plates. The achieved mean peak temperatures (808 nm: 74.1 to 112.4°C, 980 nm: 45.8 to 53.5°C), as well as the elevation of average temperatures (808 nm: 29.5 to 38.2°C, 980 nm: 27.1 to 32.6°C) were associated with pain that was equivalent to that of hair removal procedures and was not significantly different for various wavelengths. The linear scanning laser devices provide the benefits of contact-free homogeneous heating of the human nail while ensuring adequate temperature rises.

  6. Heat profiles of laser-irradiated nails.

    PubMed

    Paasch, Uwe; Nenoff, Pietro; Seitz, Anna-Theresa; Wagner, Justinus A; Kendler, Michael; Simon, Jan C; Grunewald, Sonja

    2014-01-01

    Onychomycosis is a worldwide problem with no tendency for self-healing, and existing systemic treatments achieve disease-free nails in only 35 to 76% of cases. Recently, treatment of nail fungus with a near-infrared laser has been introduced. It is assumed that fungal eradication is mediated by local heat. To investigate if laser treatment has the potential to eradicate fungal hyphae and arthrospores, laser heat application and propagation needs to be studied in detail. This study aimed to measure nail temperatures using real-time videothermography during laser irradiation. Treatment was performed using 808- and 980-nm linear scanning diode lasers developed for hair removal, enabling contact-free homogeneous irradiation of a human nail plate in one pass. Average and peak temperatures increased pass by pass, while the laser beam moved along the nail plates. The achieved mean peak temperatures (808 nm: 74.1 to 112.4°C, 980 nm: 45.8 to 53.5°C), as well as the elevation of average temperatures (808 nm: 29.5 to 38.2°C, 980 nm: 27.1 to 32.6°C) were associated with pain that was equivalent to that of hair removal procedures and was not significantly different for various wavelengths. The linear scanning laser devices provide the benefits of contact-free homogeneous heating of the human nail while ensuring adequate temperature rises.

  7. Modification of elastic stable intramedullary nailing with a 3rd nail in a femoral spiral fracture model - results of biomechanical testing and a prospective clinical study.

    PubMed

    Kaiser, Martin M; Stratmann, Christine; Zachert, Gregor; Schulze-Hessing, Maaike; Gros, Nina; Eggert, Rebecca; Rapp, Marion

    2014-01-08

    Elastic stable intramedullary nailing (ESIN) is the standard treatment for displaced diaphyseal femoral fractures in children. However, high complication rates (10-50%) are reported in complex fractures. This biomechanical study compares the stiffness with a 3rd nail implanted to that in the classical 2C-shaped configuration and presents the application into clinical practice. For each of the 3 configurations of ESIN-osteosynthesis with titanium nails eight composite femoral grafts (Sawbones®) with an identical spiral fracture were used: 2C configuration (2C-shaped nails, 2 × 3.5 mm), 3CM configuration (3rd nail from medial) and 3CL configuration (3rd nail from lateral). Each group underwent biomechanical testing in 4-point bending, internal/external rotation and axial compression. 2C and 3CM configurations showed no significant differences in this spiroid type fracture model. 3CL had a significantly higher stiffness during anterior-posterior bending, internal rotation and 9° compression than 2C, and was stiffer in the lateral-medial direction than 3CM. The 3CL was less stable during p-a bending and external rotation than both the others. As biomechanical testing showed a higher stability for the 3CL configuration in two (a-p corresponding to recurvation and 9° compression to shortening) of three directions associated with the most important clinical problems, we added a 3rd nail in ESIN-osteosynthesis for femoral fractures. 11 boys and 6 girls (2.5-15 years) were treated with modified ESIN of whom 12 were '3CL'; due to the individual character of the fractures 4 patients were treated with '3CM' (third nail from medial) and as an exception 1 adolescent with 4 nails and one boy with plate osteosynthesis. No additional stabilizations or re-operations were necessary. All patients achieved full points in the Harris-Score at follow-up; no limb length discrepancy occurred. The 3CL configuration provided a significantly higher stiffness than 2C and 3CM configurations

  8. Rapid Treatment of Subungual Onychomycosis Using Controlled Micro Nail Penetration and Terbinafine Solution.

    PubMed

    Bristow, Ivan; Baran, Robert; Score, Michelle

    2016-08-01

    Onychomycosis continues to be a common and intractable problem in adults, often responding poorly to topical treatment due to limited drug penetration of the nail plate. Improving penetration has been attempted previously by chemical and physical means with some success. The authors present three cases of toenail onychomycosis treated topical terbinafine 1% solution using controlled micro-penetration of the nail using a novel intelligent nail drill system which is able to drill nail plate without penetrating the delicate nail bed beneath. The cases illustrate how the device has been successfully employed to deliver the anti-fungal drug directly and rapidly to the site of infection with minimal side effects or complications, whilst maintaining the nail integrity.

    J Drugs Dermatol. 2016;15(8):974-978.

  9. Dermoscopic features of nail psoriasis treated with biologics.

    PubMed

    Hashimoto, Yuki; Uyama, Miki; Takada, Yuko; Yoshida, Kenji; Ishiko, Akira

    2017-05-01

    Although psoriatic nail lesions are small, they cause considerable discomfort for patients and adversely affect quality of life. Few studies have evaluated the dermoscopic features of psoriatic nails. The aim of this study was to clarify the dermoscopic features of nail psoriasis and identify those that reflect psoriatic activity. During biologic treatment of psoriasis, six patients with psoriatic nails twice underwent dermoscopic examination, with an interval of 17-42 weeks. We used the modified Nail Psoriasis Severity Index score and Psoriasis Area and Severity Index score to identify and assess dermoscopic features. We identified 10 dermoscopic findings, of which disappearance of diffuse scaling of the nail plate, transverse step-like notches and splinter hemorrhages of the nail bed, and appearance of erythematous borders of the onycholytic area were associated with improvement in Psoriasis Area and Severity Index score. Dermoscopy can detect nail changes during psoriasis treatment and should be used to evaluate treatment success. © 2017 Japanese Dermatological Association.

  10. Investigation of Human Nail Microstructure with Ultrasound

    NASA Astrophysics Data System (ADS)

    Maeva, A. R.; Bakulin, E. Y.; Denisova, L. A.; Maev, R. Gr.

    Investigation of a human fingernail and the extraction of the data on its microstructure and elastic properties is important in three main aspects. First of all, various diseases of the nail can be differentiated more precisely; second of all, it is possible to non-invasively track during time the effects of a cosmetic product upon the nail; third of all, because various processes in the organism have a strong influence upon the nail plate growth, the monitoring of the nail morphology and its mechanical properties may be used as additional information for the diagnosis of a number of medical disorders, such as systemic sclerosis, psoriasis, chronic hand eczema, anemia etc. The aim of the present study was to carry out a detailed ultrasound investigation in the high-frequency range (25-50 MHz) of a human nail including micro-anatomical structure imaging and ultrasound velocity evaluation, using B-scans obtained with a scanning acoustic microscope. On the images, exact topology of the nail, nail matrix and the underlying bone have been revealed. Additionally, a certain type of inclined internal layering along the nails of some individuals has been found, which was not reported in previous ultrasonic studies of the nail.

  11. Prospective comparative study of two methods for fixation after distal femur corrective osteotomy for valgus deformity; retrograde intramedullary nailing versus less invasive stabilization system plating.

    PubMed

    Özcan, Çağrı; Sökücü, Sami; Beng, Kubilay; Çetinkaya, Engin; Demir, Bilal; Kabukçuoğlu, Yavuz Selim

    2016-10-01

    The aim of this study was to compare the radiological and functional results of two different methods of fixation for the correction of femoral valgus deformities. Patients who had undergone osteotomy and correction of a valgus deformity from 2007 to 2013 were prospectively followed. Thirty three patients (20 females, 13 males) with 39 lower limbs were included in the study. Seventeen lower limbs were treated with retrograde intramedullary nailing (IMN) and 22 with less invasive stabilization system plating. Standing orthoroentgenograms of the lower limbs were taken pre-operatively and at the final follow-up. mLDFA, aLDFA, mechanical axis deviation (MAD) were measured in this orthoroentgenograms. Knee osteoarthritis outcome score (KOOS) and knee range of motion were used pre-operatively and at the final follow-up as part of the evaluation of the clinical results. All patients duration of surgery, length of hospital stay were assessed. Operations were performed by two orthopedic surgeons. The choice of correction method for each patient was determined by the surgeon. Pre-operative and post-operative values were simultaneously measured by two additional orthopedic surgeons. The mean age of the patients was 26.2 years (18.0-51.0) in the plating group and 29.3 years (18.0-55.0) in the nailing group. Patients in the plating and nailing groups were followed up for 24.0 (12.0-60.0) and 27.8 (12.0-60.0) months. All patients were followed for a minimum of 12 months. No significant differences were observed between the groups in terms of age, sex, or duration of follow-up (p > 0.05) Comparison of the pre- and post-operative mLDFA, aLDFA, MAD, length of hospital stay, and duration of surgery between the plating group and nailing group, no significant difference was observed between the groups (p > 0.05). However, patients treated with retrograde IMN had significantly better post-operative results in terms of the KOOS and range of motion of the knee according to

  12. An electrochemical modeling of lithium-ion battery nail penetration

    NASA Astrophysics Data System (ADS)

    Chiu, Kuan-Cheng; Lin, Chi-Hao; Yeh, Sheng-Fa; Lin, Yu-Han; Chen, Kuo-Ching

    2014-04-01

    Nail penetration into a battery pack, resulting in a state of short-circuit and thus burning, is likely to occur in electric car collisions. To demonstrate the behavior of a specific battery when subject to such incidents, a standard nail penetration test is usually performed; however, conducting such an experiment is money consuming. The purpose of this study is to propose a numerical electrochemical model that can simulate the test accurately. This simulation makes two accurate predictions. First, we are able to model short-circuited lithium-ion batteries (LIBs) via electrochemical governing equations so that the mass and charge transfer effect could be considered. Second, the temperature variation of the cell during and after nail penetration is accurately predicted with the help of simulating the temperature distribution of thermal runaway cells by thermal abuse equations. According to this nail penetration model, both the onset of battery thermal runaway and the cell temperature profile of the test are obtained, both of which are well fitted with our experimental results.

  13. Nail psoriasis masqueraded by secondary infection with Rhodotorula mucilaginosa.

    PubMed

    Martini, K; Müller, H; Huemer, H P; Höpfl, R

    2013-11-01

    A 38-year-old man presented with whitish nail changes on all fingers as the sole symptom. The condition had developed within a few days and led to dystrophy of the proximal part of the nail plates. As microscopic examination of nail scrapings demonstrated budding hyphae and the patient working as a teacher reported frequent use of a wet sponge, antifungal therapy was initiated. Subsequent cultures and molecular typing identified Rhodotorula mucilaginosa (formerly R. rubra). This environmental yeast was repeatedly isolated despite of therapy with itraconazole. As no improvement was achieved and testing of the biological activity of the fungus revealed only marginal keratolytic activity, it was considered as a coloniser of a destructed nail matrix. Finally, a biopsy of the nail bed confirmed the diagnosis of nail psoriasis, which rapidly responded to treatment with acitretin and topical calcipotriol/betamethasone cream. Fungal growth in destructed nails masqueraded the underlying disease and may have triggered the psoriatic nail reaction. © 2013 Blackwell Verlag GmbH.

  14. Knee arthrodesis with the Wichita fusion nail.

    PubMed

    Domingo, L J; Caballero, M J; Cuenca, J; Herrera, A; Sola, A; Herrero, L

    2004-02-01

    We reviewed 32 patients who all had knee arthrodesis performed after failed knee replacement. The minimum clinical follow-up was 1 year. The arthrodesis was performed by means of the Wichita fusion nail in 11, by external fixation in 15 cases, by plating in three and by intramedullary nailing in three. The mean patient age was 68.6 years. When the Wichita nail was used, fusion was achieved in ten out of 11 cases after a mean period of 4.5 (3-7) months. Of the remaining 21 patients, fusion was only achieved in 11 cases after a mean period of 6.5 (4.5-10) months.

  15. Permeation studies of novel terbinafine formulations containing hydrophobins through human nails in vitro.

    PubMed

    Vejnovic, Ivana; Huonder, Cornelia; Betz, Gabriele

    2010-09-15

    Existing treatments of onychomycosis are not satisfactory. Oral therapies have many side effects and topical formulations are not able to penetrate into the human nail plate and deliver therapeutical concentrations of active agent in situ. The purpose of the present study was to determine the amount of terbinafine, which permeates through the human nail plate, from liquid formulations containing enhancers, namely hydrophobins A-C in the concentration of 0.1% (w/v). The used reference solution contained 10% (w/v) of terbinafine in 60% (v/v) ethanol/water without enhancer. Permeability studies have been performed on cadaver nails using Franz diffusion cells modified to mount nail plates and filled with 60% (v/v) ethanol/water in the acceptor chamber. Terbinafine was quantitatively determined by HPLC. The amount of terbinafine remaining in the nail was extracted by 96% ethanol from pulverized nail material after permeation experiment and presented as percentage of the dry nail weight before the milling test. Permeability coefficient (PC) of terbinafine from reference solution was determined to be 1.52E-10 cm/s. Addition of hydrophobins improved PC in the range of 3E-10 to 2E-9 cm/s. Remaining terbinafine reservoir in the nail from reference solution was 0.83% (n=2). An increase of remaining terbinafine reservoir in the nail was observed in two out of three tested formulations containing hydrophobins compared to the reference. In all cases, known minimum inhibitory concentration of terbinafine for dermatophytes (0.003 microg/ml) has been exceeded in the acceptor chamber of the diffusion cells. All tested proteins (hydrophobins) facilitated terbinafine permeation after 10 days of permeation experiment, however one of them achieved an outstanding enhancement factor of 13.05 compared to the reference. Therefore, hydrophobins can be included in the list of potential enhancers for treatment of onychomycosis. Copyright 2010 Elsevier B.V. All rights reserved.

  16. Intramedullary fixation of forearm fractures with new locked nail.

    PubMed

    Bansal, Himanshu

    2011-09-01

    Lack of availability of interlocked nails made plate osteosynthesis the first choice of treatment of forearm fractures inspite of more surgical exposure, periosteal stripping and big skin incision subsequent scar along with higher risk of refracture on implant removal. We hereby report the first 12 cases with 19 forearm bone fractures internally fixed by indegenous interlocked nail. Existing square nails were modified to have a broad proximal end of 5.5 mm with a hole for locking screw of 2.5 mm. The nail has a distal hole of 1/1.2/1.5 mm in 2.5/3/3.5 mm diameter nail, respectively. A new method of distal locking with a clip made of k wire is designed. The clip after insertion into the bone and hole in nail and opposite cortex snuggly fits the bone providing a secure locking system. Twelve skeletally mature patients, mean age 32 years (range 24-45 years) with 19 diaphyseal fractures of the forearm were treated with this indigenously made new nail. The patient were evaluated for fracture union, functional recovery and complications. The functional outcome was assessed by disabilities of arm, shoulder and hand questionnaire (DASH score). Time to radiographic union ranged between 12 and 28 weeks, with a 100% union rate. Complications were minimal, with mild infection in open fracture (n=1) and delayed union (n=1) in patient with comminuted fracture of the ulna only. The clinical results were excellent. The DASH score ranged between 0 and 36 points. This new interlocking nail may be considered as an alternative to plate osteosynthesis for fractures of the forearm in adults. The advantages are benefit of closed reduction, smaller residual scar, reduced cost and early union with allowance of immediate movements.

  17. Knee arthrodesis using a short locked intramedullary nail. A new technique.

    PubMed

    Cheng, S L; Gross, A E

    1995-01-01

    This article reports on the use of a new intramedullary nail designed specifically for fixation of knee fusions. The nail is a short locked stainless steel nail that is inserted through a single anterior knee incision and uses an outrigger targeting rod to guide the insertion of the locking screws. The successful use of this technique is illustrated in two cases. The advantages of this nail compared with previously reported techniques of fixation for knee fusions are that the short locked nail avoids the second incision required for the insertion of long knee fusion nails, the bulkiness of the double plating technique in the relatively subcutaneous anterior knee area, and the difficulties inherent with the prolonged use of pins for external fixation.

  18. Nail or plate in the management of distal extra-articular tibial fracture, what is better? Valutation of outcomes

    PubMed Central

    Bisaccia, Michele; Cappiello, Andrea; Meccariello, Luigi; Rinonapoli, Giuseppe; Falzarano, Gabriele; Medici, Antonio; Vicente, Cristina Ibáñez; Piscitelli, Luigi; Stano, Verdiana; Bisaccia, Olga; Caraffa, Auro

    2018-01-01

    Introduction: Distal tibial fractures are the most common long bone fractures. Several studies focusing on the methods of treatment of displaced distal tibial fractures have been published. To date, locked plates, intramedullary nails and external fixation are the three most used techniques. The aim of our study was to compare intramedullary nail (IMN) and locked plate (LP) for treatment of this kind of fracture. Materials and methods: We collected data on 81 patients with distal tibial fractures (distance from the joint between 40 and 100 mm) and we divided into two groups: IMN and LP. We compared in the 2 groups the mean operation time, the mean union time, the infection rate the rate of malunion and nonunion, the full weight bearing time. Results: No patient in the two groups developed a nonunion. None of the patients obtained a fair or poor outcome. Overall 52 patients obtained an excellent result (69.3%) and 23 obtained a good result (30.6%). Discussion: Our study results indicate a superiority of IMN over LP in terms of lower rates of infections and statistically significant shorter time to full weight bearing. Whereas LP appeared to be advantageous over IMN in terms of leading to a better anatomical and fixed reductions of the fracture and a lower rate of union complications. The two treatments achieved comparable results in terms of operation time, hospital stay, union time and functional outcomes. PMID:29469802

  19. Modelling the strength of an aluminium-steel nailed joint

    NASA Astrophysics Data System (ADS)

    Goldspiegel, Fabien; Mocellin, Katia; Michel, Philippe

    2018-05-01

    For multi-material applications in automotive industry, a cast aluminium (upper layer) and dual-phase steel (lower layer) superposition joined with High-Speed Nailing process is investigated through an experimental vs numerical framework. Using FORGE® finite-element software, results from joining simulations have been inserted into models in charge of nailed-joint mechanical testings. Numerical Shear and Cross-tensile tests are compared to experimental ones to discuss discrepancy and possible improvements.

  20. Intramedullary nail fixation of non-traditional fractures: Clavicle, forearm, fibula.

    PubMed

    Dehghan, Niloofar; Schemitsch, Emil H

    2017-06-01

    Locked intramedullary fixation is a well-established technique for managing long-bone fractures. While intramedullary nail fixation of diaphyseal fractures in the femur, tibia, and humerus is well established, the same is not true for other fractures. Surgical fixations of clavicle, forearm and ankle are traditionally treated with plate and screw fixation. In some cases, fixation with an intramedullary device is possible, and may be advantageous. However, there is however a concern regarding a lack of rotational stability and fracture shortening. While new generation of locked intramedullary devices for fractures of clavicle, forearm and fibula are recently available, the outcomes are not as reliable as fixation with plates and screws. Further research in this area is warranted with high quality comparative studies, to investigate the outcomes and indication of these fractures treated with intramedullary nail devices compared to intramedullary nail fixation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Noise Source Identification and Dynamic Modeling of a Pneumatic Nailing Device =

    NASA Astrophysics Data System (ADS)

    Nili Ahmadabadi, Zahra

    Exposure to hazardous noise levels emitted by pneumatic nailing devices contributes significantly to risk of hearing damage among the construction workers throughout the world. This health problem comes from the lack of appropriate technology such as low noise devices which in turn results from the lack of scientific knowledge about designing reduced noise devices. This study contributes to the design improvement of pneumatic nailing devices through identifying the noise sources and developing the simulation tool required to redesign the pneumatic nailing device. To identify the noise sources, the study uses a combination of two complementary experimental approaches. The first makes use of time-synchronized data analysis of several variables during the machine operation. This strategy allows identifying the physical processes and provides a detailed separation of the noise generation mechanisms in successive time sequences. However, since multiple noise sources radiate at the same time, this observation approach is not sufficient for noise source identification and ranking. Thus, it is completed by a selective wrapping and muffler procedure. This technique provides overall generated noise associated with each process, as well as ranking of the three major sources: (1) exhaust noise, (2) machine body vibrations, and (3) workpiece vibrations. A special investigation is conducted on this third one with two cases: a workpiece/worktable setup representative of the actual field usage of a nailing device and a workpiece/sandbox setup used in a standardized laboratory test. The study evaluates the efficiency of the workpiece/sandbox setup in reducing the workpiece radiation and obtains a typical workpiece contribution on an actual worksite. To provide a simulation tool, a dynamic model of the pneumatic nailing device needs to be developed. Dynamic modeling of the nailing device requires mathematical modeling of the physical processes involved in its operation. All of these

  2. The use of intramedullary nails in tibiotalocalcaneal arthrodesis.

    PubMed

    Thomas, Ruth L; Sathe, Vinayak; Habib, Syed I

    2012-01-01

    Tibiotalocalcaneal arthrodesis is a salvage procedure undertaken for hindfoot problems that affect both the ankle and subtalar joints (eg, two-joint arthritis, severe acute trauma, osteonecrosis of the talus, severe malalignment deformities, significant hindfoot bone loss). Methods of achieving fusion include Steinmann pins, screws, plates, external fixators, and retrograde intramedullary nailing. Retrograde intramedullary nailing provides a load-sharing fixation device with superior biomechanical properties and is an excellent choice for use in tibiotalocalcaneal arthrodesis. This technique can be performed through relatively small incisions. In addition, recent design modifications include the availability of dynamization and the choice of curved or straight nails. Contraindications to the technique include the presence of infection, severe vascular disease, and severe malalignment of the tibia.

  3. Nail cosmetics.

    PubMed

    Madnani, Nina A; Khan, Kaleem J

    2012-01-01

    The nail as an anatomic structure protects the terminal phalanx of the digit from injury. Historically, it has served as a tool for protection and for survival. As civilizations developed, it attained the additional function of adornment. Nail beautification is a big industry today, with various nail cosmetics available, ranging from nail hardeners, polishes, extensions, artificial/sculpted nails, and nail decorations. Adverse events may occur either during the nail-grooming procedure or as a reaction to the individual components of the nail cosmetics. This holds true for both the client and the nail technician. Typically, any of the procedures involves several steps and a series of products. Separate "nail-bars" have been set up dedicated to serve women and men interested in nail beautification. This article attempts to comprehensively inform and educate the dermatologist on the services offered, the products used, and the possible/potential adverse effects related to nail-grooming and nail cosmetics.

  4. Application of cosmetic nail varnish does not affect the antifungal efficacy of amorolfine 5% nail lacquer in the treatment of distal subungual toenail onychomycosis: results of a randomised active-controlled study and in vitro assays.

    PubMed

    Sigurgeirsson, B; Ghannoum, M A; Osman-Ponchet, H; Kerrouche, N; Sidou, F

    2016-05-01

    As onychomycosis is unsightly, this study clinically evaluated whether the antifungal efficacy of amorolfine 5% nail lacquer (NL) was affected by a masking, natural-coloured, cosmetic nail varnish applied 24 h later; in vitro investigations were also performed. Subjects with mild-to-moderate distal subungual toenail onychomycosis were randomised to receive amorolfine 5% NL once weekly with or without cosmetic nail varnish applied 24 h later. After 12-week treatment, antifungal activity of affected toenail clippings was assessed by measurement of zones of inhibition (ZOIs) on Trichophyton mentagrophytes seeded agar plates. Mean diameters were 53.5 mm for the amorolfine 5% NL-alone group (n = 23) and 53.6 mm for amorolfine 5% NL plus cosmetic nail varnish group (n = 25). Also, mycological cultures of subungual debris at week 12 were negative for all subjects in both groups. Most subjects (88%) reported that cosmetic nail varnish masked their infected toenails. Additionally, cadaver human nails coated in vitro with or without cosmetic nail varnish 10 min or 24 h post amorolfine NL application all gave ZOIs on Trichophyton rubrum agar plates representing potent antifungal activity. In conclusion, cosmetic nail varnish applied post amorolfine had no effect on the subungual antifungal activity of amorolfine 5% NL or its penetration through toenails. © 2016 The Authors Mycoses published by Blackwell Verlag GmbH.

  5. Clinical features and nail clippings in 52 children with psoriasis.

    PubMed

    Uber, Marjorie; Carvalho, Vânia O; Abagge, Kerstin T; Robl Imoto, Renata; Werner, Betina

    2018-03-01

    Nail clipping, the act of cutting the distal portion of a nail for microscopic analysis, can complement the diagnosis of skin diseases with nail involvement, such as psoriasis. This study aimed to describe histopathologic findings on 81 nails from 52 children and adolescents with skin psoriasis and to determine whether these changes correlated with the severity of skin and nail involvement. Children with psoriasis were enrolled in this cross-sectional study to obtain Psoriasis Area and Severity Index (PASI) and Nail Psoriasis Severity Index (NAPSI) scores. The most altered nails were processed using periodic acid-Schiff with diastase staining. Fifty-two patients with a median age of 10.5 years were included. The median Nail Psoriasis Severity Index score of the 20 nails from these patients was 17 (range 3-80). The most common findings were pitting (94.2%), leukonychia (73.0%), and longitudinal ridges (63.5%). Eighty-one nail fragments were collected by clipping. Neutrophils were found in 6 samples (7.6%) and serous lakes in 15 (19%). Median nail plate thickness was 0.3 mm (range 0.1-0.63 mm). Patients whose nails had neutrophils had a higher median PASI score (6.1 vs 2.0, P = .03). Patients whose nails had serous lakes had higher median PASI (5.3 vs 1.9, P = .008) and NAPSI (median 45.0 vs 18.0, P = .006) scores. There seems to be a correlation between some microscopic nail features in children with psoriasis and their PASI and NAPSI scores, so nail clippings from children with suspected psoriasis may help with diagnosis, especially in the presence of neutrophils, and in excluding onychomycosis. © 2018 Wiley Periodicals, Inc.

  6. Operative treatment of 2-part surgical neck fractures of the proximal humerus (AO 11-A3) in the elderly: Cement augmented locking plate Philos™ vs. proximal humerus nail MultiLoc®.

    PubMed

    Helfen, Tobias; Siebenbürger, Georg; Mayer, Marcel; Böcker, Wolfgang; Ockert, Ben; Haasters, Florian

    2016-10-28

    Proximal humeral fractures are with an incidence of 4-5 % the third most common fractures in the elderly. In 20 % of humeral fractures there is an indication for surgical treatment according to the modified Neer-Criteria. A secondary varus dislocation of the head fragment and cutting-out are the most common complications of angle stable locking plates in AO11-A3 fractures of the elderly. One possibility to increase the stability of the screw-bone-interface is the cement augmentation of the screw tips. A second is the use of a multiplanar angle stablentramedullary nail that might provide better biomechanical properties after fixation of 2-part-fractures. A comparison of these two treatment options augmented locking plate versus multiplanar angle stable locking nail in 2-part surgical neck fractures of the proximal humerus has not been carried out up to now. Forty patients (female/male, ≥60 years or female postmenopausal) with a 2-part-fracture of the proximal humerus (AO type 11-A3) will be randomized to either to augmented plate fixation group (PhilosAugment) or to multiplanar intramedullary nail group (MultiLoc). Outcome parameters are Disabilities of the Shoulder, Arm and Hand-Score (DASH) Constant Score (CS), American Shoulder and Elbow Score (ASES), Oxford Shoulder Score (OSS), Range of motion (ROM) and Short Form 36 (SF-36) after 3 weeks, 6 weeks, 3 months, 6 months, 12 and 24 months. Because of the lack of clinical studies that compare cement augmented locking plates with multiplanar humeral nail systems after 2-part surgical neck fractures of the proximal humerus, the decision of surgical method currently depends only on surgeons preference. Because only a randomized clinical trial (RCT) can sufficiently answer the question if one treatment option provides advantages compared to the other method we are planning to perform a RCT. Clinical Trial ( NCT02609906 ), November 18, 2015, registered retrospectively.

  7. Fatigue Failure in Extra-Articular Proximal Tibia Fractures: Locking Intramedullary Nail Versus Double Locking Plates-A Biomechanical Study.

    PubMed

    Kandemir, Utku; Herfat, Safa; Herzog, Mary; Viscogliosi, Paul; Pekmezci, Murat

    2017-02-01

    The goal of this study is to compare the fatigue strength of a locking intramedullary nail (LN) construct with a double locking plate (DLP) construct in comminuted proximal extra-articular tibia fractures. Eight pairs of fresh frozen cadaveric tibias with low bone mineral density [age: 80 ± 7 (SD) years, T-score: -2.3 ± 1.2] were used. One tibia from each pair was fixed with LN, whereas the contralateral side was fixed with DLP for complex extra-articular multifragmentary metaphyseal fractures (simulating OTA 41-A3.3). Specimens were cyclically loaded under compression simulating single-leg stance by staircase method out to 260,000 cycles. Every 2500 cycles, localized gap displacements were measured with a 3D motion tracking system, and x-ray images of the proximal tibia were acquired. To allow for mechanical settling, initial metrics were calculated at 2500 cycles. The 2 groups were compared regarding initial construct stiffness, initial medial and lateral gap displacements, stiffness at 30,000 cycles, medial and lateral gap displacements at 30,000 cycles, failure load, number of cycles to failure, and failure mode. Failure metrics were reported for initial and catastrophic failures. DLP constructs exhibited higher initial stiffness and stiffness at 30,000 cycles compared with LN constructs (P < 0.03). There were no significant differences between groups for loads at failure or cycles to failure. For the fixation of extra-articular proximal tibia fractures, a LN provides a similar fatigue performance to double locked plates. The locked nail could be safely used for fixation of proximal tibia fractures with the advantage of limited extramedullary soft tissue damage.

  8. Prediction of a nail polish colour applied on a nail.

    PubMed

    Monpeurt, C; Cinotti, E; Razafindrakoto, J; Rubegni, P; Fimiani, M; Perrot, J L; Hebert, M

    2018-02-01

    The colour of a nail polish varies according to the nail on which it is applied. The objective of this study was to predict the colour of the nail polish on a given nail and to study how the colour varies depending on the nail polish thickness. Six nail polishes were applied in one, two and three layers on the nails of one subject, thus forming eighteen samples. The spectral reflectances of the eighteen nail polishes applied on the nails with different thicknesses were obtained by spectrophotometry. The spectral reflectances of the nails without polish were also measured using the same technique. The thicknesses of nail polishes were measured by high-definition optical coherence tomography (HD-OCT). Then, to determine the physical parameters of the nail polish itself, we applied the six nail polishes on an opacity drawdown chart and we measured the spectral reflectance and the thickness of each patch using spectrophotometry and HD-OCT, respectively. The Kubelka-Munk theory was used to get the predicted spectral reflectance of the nail polish applied on the nail according to the polish thickness by knowing the parameter of the polish itself and the spectral reflectance of the nail. The predicted spectral reflectances were finally compared with those measured directly on the nails. The predicted spectral reflectances were rather close to measured ones. Consequently, knowing the colour of the nail without polish and the optical parameters of the nail polish itself, we can estimate the colour of the nail polish applied on the nail depending on its thickness. Our study showed that the Kubelka-Munk theory can be used to predict the nail polish colour. The ability to predict the real colour of a nail polish applied on a nail could help a nail polish manufacturer to improve his polish formulae in order to obtain a precise colour. © 2017 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  9. Changes in nail keratin observed by Raman spectroscopy after Nd:YAG laser treatment.

    PubMed

    Shin, Min Kyung; Kim, Tae In; Kim, Wan Sun; Park, Hun-Kuk; Kim, Kyung Sook

    2017-04-01

    Lasers and photodynamic therapy have been considered a convergence treatment for onychomycosis, which is a fungal infection on the nail bed and nail plate. Laser therapies have shown satisfactory results without significant complications for onychomycosis; however, the mechanism of clearing remains unknown. In this work, we investigated changes in the chemical structure of nail keratin induced by Nd:YAG laser using Raman spectroscopy. Toe nails with onychomycosis were treated with 1064 nm Nd:YAG laser. After laser treatment, the disulfide band (490-590 cm -1 ) of nail keratin was rarely observed or was reduced in intensity. The amide I band (1500-1700 cm -1 ) also showed changes induced by the laser. The α-helical (1652 cm -1 ) structures dominated the β-sheet (1673 cm -1 ) in nontreated nail, but the opposite phenomenon was observed after laser treatment. © 2016 Wiley Periodicals, Inc.

  10. Management of comminuted proximal ulna fracture-dislocations using a multiplanar locking intramedullary nail.

    PubMed

    Edwards, Scott G; Argintar, Evan; Lamb, Joshua

    2011-06-01

    Intramedullary nails have been used for the fixation of olecranon fractures in an attempt to reduce the soft tissue irritation and resulting need for hardware removal seen with plating and tension banding. Further benefits include preservation of vascular supply, and increase stability and improved compression over some alternative techniques. Most intramedullary nails have been limited to simple olecranon fractures or osteotomies. One novel multiplanar, locking intramedullary nail, however, is indicated to stabilize all fracture patterns of the proximal ulna, including the coronoid. This particular locking nail has screws that radiate in multiple planes and form a fixed-angle lattice throughout the bone. The nail also has fixed-angle screws dedicated to the 3 parts of the coronoid: process tip, medial facet, and medial wall. This allows the nail to secure multiple fragments regardless of the fracture pattern's extent of instability. The objective of this article is to illustrate the recommended steps in reducing and stabilizing a comminuted proximal ulna fracture-dislocation using this multiplanar locking intramedullary nail.

  11. [Comparison of effect between early and delayed in primary intramedullary nailing combined with locked plate fixation for the treatment of multi-segments tibial fractures of type].

    PubMed

    Gao, Wei-qiang; Hu, Jiang-hai; Gu, Zhu-chao; Zhang, Huai-xian; Min, Peng; Zhang, Lin-jun; Yu, Wen-wen; Wang, Guang-lin

    2015-02-01

    To compare the clinical results of early and delayed intramedullary nailing and locked plating for the treatment of multi-segments tibial fractures of type AO/ASIF-42C2. Between January 2010 and January 2013,45 patients with multi-segments closed tibial fractures of AO/ASIF-42C2 were treated by early primary intramedullary nailing and locked plating in 20 cases as early group and delayed in 25 cases as delayed group. In early group,20 cases included 13 males and 7 females with an average age of (37.9±14.3) years old ranging from 20 to 56 years;according to soft tissue injury Tscherne classification, 8 fractures were frade I,12 were grade II. In delayed group, 25 cases included 17 males and 8 females with an average age of (38.7±17.2) years old ranging from 24 to 55 years,4 fractures were grade I ,19 were grade II ,2 were grade III. The operative time, blood loss, hospital stay,fracture healing time and complications were recorded. At final follow-up, the Johner-Wruhs score were used to evaluate functional efficacy, and the posterior-anterior and lateral X-ray to evaluate fracture reduction and alignment. All the patients were followed up for (12.5±2.5) months in early group and (13.2±2.8) months in delayed group (P>0.05). No wounds infections were happened. At the last follow-up, the mean range of knee joint was 10°-0°-120°. According to Johner-Wruhs scoring,there were 15 cases in excellent,3 in good,fair in 2 in early group; 21 in excellent,2 in good,2 in fair. The average operative time,blood loss had no significant differences between two groups (P>0.05), but hospital stay in early group was significantly shorter than those in delayed group(P<0.05). Average fracture healing time of early group and delayed group were (5.3±2.6) months and (6.0±2.9) months, respectively (P>0.05). For multi-segments tibial fractures of type AO/ASIF-42C2 with preoperative minor soft tissue injuries lighter of Tscherne grade I or II, early primary intramedullary nailing and

  12. Nail abnormalities

    MedlinePlus

    ... appearance of the thumbnails. Long-term exposure to moisture or nail polish can cause nails to peel ... nail, if your nails are constantly exposed to moisture, or whether you are always picking at your ...

  13. Novel management of distal tibial and fibular fractures with Acumed fibular nail and minimally invasive plating osteosynthesis technique: A case report.

    PubMed

    Wang, Tie-Jun; Ju, Wei-Na; Qi, Bao-Chang

    2017-03-01

    Anatomical characteristics, such as subcutaneous position and minimal muscle cover, contribute to the complexity of fractures of the distal third of the tibia and fibula. Severe damage to soft tissue and instability ensure high risk of delayed bone union and wound complications such as nonunion, infection, and necrosis. This case report discusses management in a 54-year-old woman who sustained fractures of the distal third of the left tibia and fibula, with damage to overlying soft tissue (swelling and blisters). Plating is accepted as the first choice for this type of fracture as it ensures accurate reduction and rigid fixation, but it increases the risk of complications. Closed fracture of the distal third of the left tibia and fibula (AO: 43-A3). After the swelling was alleviated, the patient underwent closed reduction and fixation with an Acumed fibular nail and minimally invasive plating osteosynthesis (MIPO), ensuring a smaller incision and minimal soft-tissue dissection. At the 1-year follow-up, the patient had recovered well and had regained satisfactory function in the treated limb. The Kofoed score of the left ankle was 95. Based on the experience from this case, the operation can be undertaken safely when the swelling has been alleviated. The minimal invasive technique represents the best approach. Considering the merits and good outcome in this case, we recommend the Acumed fibular nail and MIPO technique for treatment of distal tibial and fibular fractures.

  14. Intramedullary nailing versus plating for extra-articular distal tibial metaphyseal fracture: a systematic review and meta-analysis.

    PubMed

    Xue, Xing-He; Yan, Shi-Gui; Cai, Xun-Zi; Shi, Ming-Min; Lin, Tiao

    2014-04-01

    With development in the techniques of reduction and fixation, there has been a controversy in comparison between intramedullary nailing (IMN) and plating for the treatment of distal tibial metaphyseal fracture (DTF). The study aimed to investigate: (1) which fixation, IMN or plating, was better in the clinical outcomes and in the complications for the treatment of DTF and (2) which modifying variables affected the comparative results between the two modalities. PubMed, EMBASE, OVID, Scopus, ISI Web of Science, the Cochrane Library, Google Scholar and specific orthopaedic journals were searched from inception to July 2013, using the search strategy of '('Fracture Fixation, Intramedullary' [MeSH]) AND ('Tibial Fractures' [MeSH]) AND (plate OR plating)'. All prospective and retrospective controlled trials comparing function, pain, bone union and complications between IMN and plating for DTF were identified. Our analysis had no limitation of the language or the publication year. The primary outcome measurements were complication rate, union time, operation time and hospital stays, while the secondary outcome measurements were functional score and pain score. Fourteen of 6620 studies with 842 patients were included. IMN was probably preferential to plating for DTF given its higher functional score (p=0.01), lower risk of infection (p=0.02) and comparable pain score (p=0.33), total complication rate (p=0.53) and time to union (p=0.86). However, plating had a lower malunion rate than IMN (p<0.0001). All the results were based on the Grading of Recommendations Assessment, Development and Evaluation (GRADE) evidence of moderate quality. With a satisfying alignment obtained, IMN may be preferential to plating for fixation of DTF with better function and lower risk of infection. However, IMN showed higher malunion rate for fixation of DTF. With the biases in our meta-analysis, it will ultimately require a rigorous and adequately powered randomised controlled trial (RCT) to

  15. Biomechanical investigation of a novel ratcheting arthrodesis nail.

    PubMed

    McCormick, Jeremy J; Li, Xinning; Weiss, Douglas R; Billiar, Kristen L; Wixted, John J

    2010-10-14

    Knee or tibiotalocalcaneal arthrodesis is a salvage procedure, often with unacceptable rates of nonunion. Basic science of fracture healing suggests that compression across a fusion site may decrease nonunion. A novel ratcheting arthrodesis nail designed to improve dynamic compression is mechanically tested in comparison to existing nails. A novel ratcheting nail was designed and mechanically tested in comparison to a solid nail and a threaded nail using sawbones models (Pacific Research Laboratories, Inc.). Intramedullary nails (IM) were implanted with a load cell (Futek LTH 500) between fusion surfaces. Constructs were then placed into a servo-hydraulic test frame (Model 858 Mini-bionix, MTS Systems) for application of 3 mm and 6 mm dynamic axial displacement (n = 3/group). Load to failure was also measured. Mean percent of initial load after 3-mm and 6-mm displacement was 190.4% and 186.0% for the solid nail, 80.7% and 63.0% for the threaded nail, and 286.4% and 829.0% for the ratcheting nail, respectively. Stress-shielding (as percentage of maximum load per test) after 3-mm and 6-mm displacement averaged 34.8% and 28.7% (solid nail), 40.3% and 40.9% (threaded nail), and 18.5% and 11.5% (ratcheting nail), respectively. In the 6-mm trials, statistically significant increase in initial load and decrease in stress-shielding for the ratcheting vs. solid nail (p = 0.029, p = 0.001) and vs. threaded nail (p = 0.012, p = 0.002) was observed. Load to failure for the ratcheting nail; 599.0 lbs, threaded nail; 508.8 lbs, and solid nail; 688.1 lbs. With significantly increase of compressive load while decreasing stress-shielding at 6-mm of dynamic displacement, the ratcheting mechanism in IM nails may clinically improve rates of fusion.

  16. Biomechanical investigation of a novel ratcheting arthrodesis nail

    PubMed Central

    2010-01-01

    Background Knee or tibiotalocalcaneal arthrodesis is a salvage procedure, often with unacceptable rates of nonunion. Basic science of fracture healing suggests that compression across a fusion site may decrease nonunion. A novel ratcheting arthrodesis nail designed to improve dynamic compression is mechanically tested in comparison to existing nails. Methods A novel ratcheting nail was designed and mechanically tested in comparison to a solid nail and a threaded nail using sawbones models (Pacific Research Laboratories, Inc.). Intramedullary nails (IM) were implanted with a load cell (Futek LTH 500) between fusion surfaces. Constructs were then placed into a servo-hydraulic test frame (Model 858 Mini-bionix, MTS Systems) for application of 3 mm and 6 mm dynamic axial displacement (n = 3/group). Load to failure was also measured. Results Mean percent of initial load after 3-mm and 6-mm displacement was 190.4% and 186.0% for the solid nail, 80.7% and 63.0% for the threaded nail, and 286.4% and 829.0% for the ratcheting nail, respectively. Stress-shielding (as percentage of maximum load per test) after 3-mm and 6-mm displacement averaged 34.8% and 28.7% (solid nail), 40.3% and 40.9% (threaded nail), and 18.5% and 11.5% (ratcheting nail), respectively. In the 6-mm trials, statistically significant increase in initial load and decrease in stress-shielding for the ratcheting vs. solid nail (p = 0.029, p = 0.001) and vs. threaded nail (p = 0.012, p = 0.002) was observed. Load to failure for the ratcheting nail; 599.0 lbs, threaded nail; 508.8 lbs, and solid nail; 688.1 lbs. Conclusion With significantly increase of compressive load while decreasing stress-shielding at 6-mm of dynamic displacement, the ratcheting mechanism in IM nails may clinically improve rates of fusion. PMID:20942976

  17. Minimally invasive plate augmentation in the treatment of long-bone non-unions.

    PubMed

    Park, Ki-Chul; Oh, Chang-Wug; Kim, Joon-Woo; Park, Kyeong-Hyeon; Oh, Jong-Keon; Park, Il-Hyung; Kyung, Hee-Soo; Heo, Jeong

    2017-11-01

    Exchange nailing is most acceptable for treating hypertrophic non-union of the long bones, requiring the removal of previously fixed implant. However, its main effect of mechanical stabilization is controversial in non-isthmal area. We hypothesized that minimally invasive plate augmentation over the non-union site may have a better option, without the need of bone grafting or removing pre-existing implants. Seventeen patients with hypertrophic non-union of the long bones between 2010 and 2014 on radiography who previously underwent intramedullary (IM) nailing or plate osteosynthesis for long-bone fractures were included. A locking compression plate was inserted with at least three mono- or bicortical screws at each proximal and distal segment. Broken or loosened interlocking screws of IM nail were simultaneously re-fixed. Fracture site exposure, pre-fixed implant removal, and bone grafting were not performed. We investigated whether union occurred and analyzed functional outcomes and complications. Eleven femoral and six tibial non-unions were prospectively included. In the pre-existing implants, 13 nails and 4 plates were found. All cases achieved union at a mean 22.7 weeks. One case of superficial infection was managed with oral antibiotics. Deep infection or implant failure did not occur. Minimally invasive plate augmentation can achieve additional stability and promote healing of hypertrophic non-union of the long bones. When indicated, this technique is the least invasive alternative to exchange nailing and reduces surgical risks in the treatment of diaphyseal non-union.

  18. Enhanced econazole penetration into human nail by 2-n-nonyl-1,3-dioxolane.

    PubMed

    Hui, Xiaoying; Chan, Thomas C K; Barbadillo, Sherry; Lee, Christine; Maibach, Howard I; Wester, Ronald C

    2003-01-01

    This study determines the enhancing effects of 2-n-nonyl-1,3-dioxolane on the penetration of econazole, an antifungal drug, into the deeper layers of the human nail where fungal infection resides. Aliquots (10 microL) of Econail lacquer formulation containing 0.45 mg of [(14)C]-econazole with 18% 2-n-nonyl-1,3-dioxolane (test group) or without 2-n-nonyl-1,3-dioxolane (control group) were applied twice daily for 14 days to human nails that had been washed with ethanol before each morning's application. The hydration of the nail sample was well controlled to simulate normal physiological conditions. After 14 days of dosing, the inner ventral section of the nail plate was assayed for absorbed drug content, using a micrometer-controlled drilling and nail powder removal system. The mass balance values of [(14)C]-econazole in this study were 90.8 and 96.4% for the test and control groups, respectively. The weight-normalized econazole content in the ventral/intermediate nail plate center in the test group was 6-fold greater than that in the control (p = 0.008). The total econazole absorbed into the supporting bed cotton ball in the test group was nearly 200-fold greater than that in the control group (p = 0.008) over the 14-day period. The amount of econazole after dosing in the inner part of the human nail (potential diseased area) was 11.1 +/- 2.6 (SD) microg/mg of nail powder with 2-n-nonyl-1,3-dioxolane in the lacquer and 1.78 +/- 0.32 microg/mg without 2-n-nonyl-1,3-dioxolane (p = 0.008). The surface nail contained more econazole (p = 0.004), that is, nonabsorbed drug, where 2-n-nonyl-1,3-dioxolane was not part of the dosing solution. Econazole in the support bed under the nail (the total absorbed dose) was 47.5 +/- 22.0 mg in the lacquer with 2-n-nonyl-1,3-dioxolane and 0.2 +/- 0.1 mg in the lacquer without 2-n-nonyl-1,3-dioxolane (p = 0.008). Moreover the concentration in the deep nail layer in the test group is 14,000 times higher than minimum inhibitory

  19. Intramedullary nailing in opening wedge high tibial osteotomy-in vitro test for validation of a method of fixation.

    PubMed

    Burchard, Rene; Katerla, Denise; Hammer, Marina; Pahlkötter, Anke; Soost, Christian; Dietrich, Gerhard; Ohrndorf, Arne; Richter, Wolfgang; Lengsfeld, Markus; Christ, Hans-Jürgen; Graw, Jan Adriaan; Fritzen, Claus-Peter

    2018-02-01

    Opening wedge high tibial osteotomy (HTO) as a treatment in unicompartimental osteoarthritis of the knee can significantly relieve pain and prevent or at least delay an early joint replacement. The fixation of the osteotomy has undergone development and refinements during the last years. The angle-stable plate fixator is currently one of the most commonly used plates in HTOs. The angular stable fixation between screws and the plate offers a high primary stability to retain the correction with early weight-bearing protocols. This surgical technique is performed as a standard of care and generally well tolerated by the patients. Nevertheless, some studies observed that many patients complained about discomfort related to the implant. Therefore, the stability of two different intramedullary nails, a short implant used in humeral fractures and a long device used in tibial fractures for stabilization in valgus HTOs, was investigated as an alternative fixation technique. The plate fixator was defined as reference standard. Nine synthetic tibia models were standardly osteotomized and stabilized by one of the fixation devices. Axial compression was realized using a special testing machine and two protocols were performed: a multi-step fatigue test and a load-to-failure test. Overall motion, medial, and lateral displacements were documented. Fractures always occurred at the lateral cortex. Axial cyclic loading up to 800 N was tolerated by all implants without failure. The tibia nail provided highest fatigue strength under the load-to-failure conditions. The results suggest that intramedullary nailing might be used as an alternative concept in HTO.

  20. Fibular fixation as an adjuvant to tibial intramedullary nailing in the treatment of combined distal third tibia and fibula fractures: a biomechanical investigation.

    PubMed

    Morin, Paul M; Reindl, Rudolf; Harvey, Edward J; Beckman, Lorne; Steffen, Thomas

    2008-02-01

    Distal third tibia fractures have classically been treated with standard plating, but intramedullary (IM) nailing has gained popularity. Owing to the lack of interference fit of the nail in the metaphyseal bone of the distal tibia, it may be beneficial to add rigid plating of the fibula to augment the overall stability of fracture fixation in this area. This study sought to assess the biomechanical effect of adding a fibular plate to standard IM nailing in the treatment of distal third tibia and fibula fractures. Eight cadaveric tibia specimens were used. Tibial fixation consisted of a solid titanium nail locked with 3 screws distally and 2 proximally, and fibular fixation consisted of a 3.5 mm low-contact dynamic compression plate. A section of tibia and fibula was removed. Testing was accomplished with an MTS machine. Each leg was tested 3 times; with and without a fibular plate and with a repetition of the initial test condition. Vertical displacements were tested with an axial load up to 500 N, and angular rotation was tested with torques up to 5 N*m. The difference in axial rotation was the only statistically significant finding (p = 0.003), with fibular fixation resulting in 1.1 degrees less rotation through the osteotomy site (17.96 degrees v. 19.10 degrees ). Over 35% of this rotational displacement occurred at the nail-locking bolt interface with the application of small torsional forces. Fibular plating in addition to tibial IM fixation of distal third tibia and fibula fractures leads to slightly increased resistance to torsional forces. This small improvement may not be clinically relevant.

  1. Update on nail cosmetics.

    PubMed

    Jefferson, Julie; Rich, Phoebe

    2012-01-01

    Nail cosmetics are used by millions of people worldwide who desire smooth, lustrous nails. The nail cosmetic industry continues to expand to meet increasing consumer demand. In 2011 alone, consumers spent $6.6 billion on nail salon services. Although nail cosmetics are relatively safe, poor application techniques can promote disease, deformity, and allergic and irritant contact dermatitis. The foundation for managing nail cosmetic problems is prevention through education. Familiarity with the procedures and materials used in the nail cosmetic industry is necessary in order to recommend safe nail care strategies. © 2012 Wiley Periodicals, Inc.

  2. New Polyurethane Nail Lacquers for the Delivery of Terbinafine: Formulation and Antifungal Activity Evaluation.

    PubMed

    Gregorí Valdes, Barbara S; Serro, Ana Paula; Gordo, Paulo M; Silva, Alexandra; Gonçalves, Lídia; Salgado, Ana; Marto, Joana; Baltazar, Diogo; Dos Santos, Rui Galhano; Bordado, João Moura; Ribeiro, Helena Margarida

    2017-06-01

    Onychomycosis is a fungal nail infection. The development of new topical antifungal agents for the treatment of onychomycosis has focused on formulation enhancements that optimize the pharmacological characteristics required for its effective treatment. Polyurethanes (PUs) have never been used in therapeutic nail lacquers. The aim of this work has been the development of new PU-based nail lacquers with antifungal activity containing 1.0% (wt/wt) of terbinafine hydrochloride. The biocompatibility, wettability, and the prediction of the free volume in the polymeric matrix were assessed using a human keratinocytes cell line, contact angle, and Positron Annihilation Lifetime Spectroscopy determinations, respectively. The morphology of the films obtained was confirmed by scanning electron microscopy, while the nail lacquers' bioadhesion to nails was determined by mechanical tests. Viscosity, in vitro release profiles, and antifungal activity were also assessed. This study demonstrated that PU-terbinafine-based nail lacquers have good keratinocyte compatibility, good wettability properties, and adequate free volume. They formed a homogenous film after application, with suitable adhesion to the nail plate. Furthermore, the antifungal test results demonstrated that the terbinafine released from the nail lacquer Formulation A PU 19 showed activity against dermatophytes, namely Trichophyton rubrum. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  3. Nail disorders in older people, and aspects of their pharmaceutical treatment.

    PubMed

    Murdan, Sudaxshina

    2016-10-30

    The aim of this paper was to explore how aging influences the nail unit, its disorders and its response to treatment, and to identify some of the age-related gaps in the ungual drug delivery literature. Aging causes obvious changes to the nail, some of which are inherently due to old age, while others are due to diseases/conditions which become more prevalent as we age. Alterations in the nail plate's colour, contour, thickness, fragility, surface features, cell size, chemical composition and growth rate are some of the changes, with toenails and fingernails showing different effects. With respect to disease, the incidence of onychomycosis - the most common nail disorder - is considerably higher in older people. Similarly, brittle nails become more common as we age. In contrast, the literature about aging and the incidence of nail psoriasis is inconclusive, although, it is clear that as one gets older, the negative impact of nail psoriasis on one's quality of life decreases. Pharmaceutical treatment of the diseases comprises local and systemic therapies, sometimes in combination. Systemic therapies have the inherent disadvantages of adverse systemic effects, drug interactions and the need for monitoring, disadvantages which are especially problematic for older people who are more likely to suffer from co-morbidities and be on other medications. Topical therapy avoids such disadvantages. However, the success rates of commercially available preparations are low, and older people may need help with their application. It is also proposed that regular inspection and grooming of nails should become part of routine care of older people, as these would provide opportunities to identify and treat any problems at an earlier stage. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Factors influencing interlocking screw failure in unreamed small diameter nails--a biomechanical study using a distal tibia fracture model.

    PubMed

    Weninger, Patrick; Schueller, Michael; Jamek, Michael; Stanzl-Tschegg, Stefanie; Redl, Heinz; Tschegg, Elmar K

    2009-05-01

    Unreamed tibia nails with small diameters are increasingly used for fracture fixation. However, little is known about the fatigue strength of proximal and distal interlocking screws in those nails. To date, no data are available reporting on mechanical differences of solid compared to cannulated tibial nails. The aim of this study was to assess the fatigue strength of proximal and distal interlocking screws of solid and cannulated small diameter tibia nails. We created a distal tibia fracture model (AO/OTA 43 A3) using 16 Sawbones. After fracture stabilization with one of four different nail types (Expert Tibial Nail, VersaNail, T2 Tibial Nailing System, Connex), mechanical testing was performed in three loading series (40,000 cycles each) with incremental loads. Timing and type of interlocking screw failure were assessed. Interlocking screw failure was observed significantly earlier (after a mean interval of 57,042 cycles) in cannulated tibial nails (VersaNail, T2) compared to solid nails (after a mean interval of 88,415 cycles; P < 0.001). Proximal interlocking screw failure was recorded if oblique screws were used proximally (VersaNail, T2, Connex). No distal interlocking screw failure was recorded in the Connex nail. Two- and three-part fractures of proximal or distal interlocking screws were observed in all specimen. Proximal and distal interlocking screw failure has to be considered in small diameter nails in case of delayed fracture healing. To support our results, further experimental studies and clinical series are necessary.

  5. Green Nail Syndrome

    MedlinePlus

    ... nail is detached from the nail bed, the waterproof seal formed by the skin on the nail ... should also be noted that wearing tight-fitting shoes for a prolonged time, especially while exercising, is ...

  6. Tension band plating of a nonunion anterior tibial stress fracture in an athlete.

    PubMed

    Merriman, Jarrad A; Villacis, Diego; Kephart, Curtis J; Rick Hatch, George F

    2013-07-01

    The authors present a rare technique of tension band plating of the anterior tibia in the setting of a nonunion stress fracture. Surgical management with an intramedullary nail is a viable and proven option for treating such injuries. However, in treating elite athletes, legitimate concerns exist regarding the surgical disruption of the extensor mechanism and the risk of anterior knee pain associated with intramedullary nail use. The described surgical technique demonstrates the use of tension band plating as an effective treatment of delayed union and nonunion anterior tibial stress fractures in athletes without the potential risks of intramedullary nail insertion. Copyright 2013, SLACK Incorporated.

  7. Limb lengthening over plate

    PubMed Central

    Kulkarni, Ruta; Singh, Nishant; Kulkarni, Govind S; Kulkarni, Milind; Kulkarni, Sunil; Kulkarni, Vidisha

    2012-01-01

    Background: The limb lengthening over plate eliminates the associated risk of infection with limb lengthening over intramedullary nail. We present our experience of limb lengthening in 15 patients with a plate fixed on the proximal segment, followed by corticotomy and application of external fixator. Materials and Methods: 15 patients (7 females, 8 males) were included in this consecutive series. The average age was 18.1 years (range 8–35 years). Fifteen tibiae and one femur were lengthened in 15 patients. Lengthening was achieved at 1 mm/day followed by distal segment fixation with three or four screws on reaching the target length. Results: The preoperative target length was successfully achieved in all patients at a mean of 4.1 cm (range 1.8–6.5 cm). The mean duration of external fixation was 75.3 days (range 33–116 days) with the mean external fixation index at 19.2 days/cm (range 10.0–38.3 days/cm). One patient suffered deep infection up to the plate, three patients had mild procurvatum deformities, and one patient developed mild tendo achilles contracture. Conclusion: Lengthening over a plate allows early removal of external fixator and eliminates the risk of creating deep intramedullary infection as with lengthening over nail. Lengthening over plate is also applicable to children with open physis. PMID:22719123

  8. A quantitative method for measuring forces applied by nail braces.

    PubMed

    Erdogan, Fatma G

    2011-01-01

    Nail bracing is a conservative method used for ingrown nails; however, lack of objective measurements limits its use for various nails. Double-string nail braces with extra metal springs were applied to 12 patients with 21 chronic, thick, and overcurved ingrown nails. Force was measured with a force gauge meter. Treatment was stopped once patients stood on their tiptoes and walked in shoes pain free without braces. A force gauge meter was also used on a model nail to show the forces applied by various nail braces and to compare their pulling forces. After 6 to 10 months of treatment, all of the patients were pain free; 600 to 1,000 centi Newtons of force were applied to the nails. As the width of the nail increased, so did the force. Braces exert more force on larger nails, which may shorten treatment durations. By measuring forces, it may be possible to standardize force and duration of treatment according to variables such as nail thickness, nail width, angle of ingrown nail, and duration of symptoms.

  9. Understanding the Formidable Nail Barrier: A Review of the Nail Microstructure, Composition and Diseases

    PubMed Central

    Baswan, Sudhir; Kasting, Gerald B.; Li, S. Kevin; Wickett, Randy; Adams, Brian; Eurich, Sean; Schamper, Ryan

    2016-01-01

    The topical treatment of nail fungal infections has been a focal point of nail research in the past few decades as it offers a much safer and focused alternative to conventional oral therapy. Although the current focus remains on exploring the ways of enhancing permeation through the formidable nail barrier, the understanding of the nail microstructure and composition is far from complete. This article reviews our current understanding of the nail microstructure, composition and diseases. A few of the parameters affecting the nail permeability and potential causes of the recurrence of fungal nail infection are also discussed. PMID:28098391

  10. Understanding the formidable nail barrier: A review of the nail microstructure, composition and diseases.

    PubMed

    Baswan, Sudhir; Kasting, Gerald B; Li, S Kevin; Wickett, Randy; Adams, Brian; Eurich, Sean; Schamper, Ryan

    2017-05-01

    The topical treatment of nail fungal infections has been a focal point of nail research in the past few decades as it offers a much safer and focused alternative to conventional oral therapy. Although the current focus remains on exploring the ways of enhancing permeation through the formidable nail barrier, the understanding of the nail microstructure and composition is far from complete. This article reviews our current understanding of the nail microstructure, composition and diseases. A few of the parameters affecting the nail permeability and potential causes of the recurrence of fungal nail infection are also discussed. © 2017 Blackwell Verlag GmbH.

  11. Nail psoriasis in an adult successfully treated with a series of herbal skin care products family – a case report.

    PubMed

    Tirant, M; Hercogovấ, J; Fioranelli, M; Gianfaldoni, S; Chokoeva, A A; Tchernev, G; Wollina, U; Novotny, F; Roccia, M G; Maximov, G K; França, K; Lotti, T

    2016-01-01

    Psoriasis is a common chronic inflammatory dermatosis that causes significant distress and morbidity. Approximately 50% of patients with cutaneous psoriasis and 90% of patients with psoriatic arthritis demonstrate nail involvement of their psoriasis. Left untreated, nail psoriasis may progress to debilitating nail disease that leads to not only impairment of function but also on quality of life. We report the case of a 50-year-old male patient with recalcitrant nail dystrophies on the fingers since the age of 40, who responded successfully to Dr. Michaels® product family. The patient had a 35-year history of plaque psoriasis localised on the scalp, ears, groin, limbs, and trunk and with psoriatic arthritis. The nail symptoms consisted of onycholysis, onychomycosis, leukonychia, transverse grooves, nail plate crumbling and paronychia of the periungal skin. This case represents the efficacy and safety of the Dr. Michaels® (Soratinex® and Nailinex®) product family with successful resolution of nail dystrophies and surrounding paronychia with no reported adverse events.

  12. Reliability, validity and feasibility of nail ultrasonography in psoriatic arthritis.

    PubMed

    Arbault, Anaïs; Devilliers, Hervé; Laroche, Davy; Cayot, Audrey; Vabres, Pierre; Maillefert, Jean-Francis; Ornetti, Paul

    2016-10-01

    To determine the feasibility, reliability and validity of nails ultrasonography in psoriatic arthritis as an outcome measure. Pilot prospective single-centre study of eight ultrasonography parameters in B mode and power Doppler concerning the distal interphalangeal (DIP) joint, the matrix, the bed and nail plate. Intra-observer and inter-observer reliability was evaluated for the seven quantitative parameters (ICC and kappa). Correlations between ultrasonography and clinical variables were searched to assess external validity. Feasibility was assessed by the time to carry out the examination and the percentage of missing data. Twenty-seven patients with psoriatic arthritis (age 55.0±16.2 years, disease duration 13.4±9.4 years) were included. Of these, 67% presented nail involvement on ultrasonography vs 37% on physical examination (P<0.05). Reliability was good (ICC and weighted kappa>0.75) for the seven quantitative parameters, except for synovitis of the DIP joint in B mode. The synovitis of the DIP joint revealed by ultrasonography correlated with the total number of clinical synovitis and Doppler US of the nail (matrix and bed). Doppler US of the matrix correlated with VAS pain but not with the ASDAS-CRP or with clinical enthesitis. No significant correlation was found with US nail thickness. The feasibility and reliability of ultrasonography of the nail in psoriatic arthritis appear to be satisfactory. Among the eight parameters evaluated, power Doppler of the matrix which correlated with local inflammation (DIP joint and bed) and with VAS pain could become an interesting outcome measure, provided that it is also sensitive to change. Copyright © 2015 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  13. Clinical and dermoscopic clues to differentiate pigmented nail bands: an International Dermoscopy Society study.

    PubMed

    Benati, E; Ribero, S; Longo, C; Piana, S; Puig, S; Carrera, C; Cicero, F; Kittler, H; Deinlein, T; Zalaudek, I; Stolz, W; Scope, A; Pellacani, G; Moscarella, E; Piraccini, B M; Starace, M; Argenziano, G

    2017-04-01

    Longitudinal melanonychia might be difficult to differentiate and the use of dermoscopy can be useful for the preoperative evaluation and management decision. The aim of our study was to investigate clinical and dermoscopic criteria of acquired longitudinal melanonychia in adults to identify the best predictors of melanoma using a multivariate analysis and to explore eventual new dermoscopic criteria for nail melanoma diagnosis. In this retrospective observational study, 82 histopathologically diagnosed, acquired nail pigmented bands were collected and examined. All variables were included in the analysis and examined as possible predictors of nail melanoma. Both univariate and multivariable analyses have been performed. Among 82 cases, 25 were diagnosed as nail melanoma and 57 as benign lesions (including 32 melanocytic nevi and 25 benign melanocytic hyperplasia). Melanoma cases were significantly associated with a width of the pigmented band higher than 2/3 of the nail plate, grey and black colours, irregularly pigmented lines, Hutchinson and micro-Hutchinson signs, and nail dystrophy. Granular pigmentation, a newly defined dermoscopic criterion, was found in 40% of melanomas and only in 3.51% of benign lesions. Dermoscopic examination of longitudinal melanonychia provides useful information that could help clinicians to improve melanoma recognition. © 2016 European Academy of Dermatology and Venereology.

  14. Management of Nail Bed Injuries Associated with Fingertip Injuries.

    PubMed

    George, Alexander; Alexander, Reena; Manju, C

    2017-01-01

    and timely diagnosis of nail bed injury and its meticulous repair is cardinal to the management of any nail bed injury. However all nail bed injuries must be seen in the context of associated injuries of the finger tip complex, namely skin, soft tissue and distal phalanx injuries. Fixation of associated bony injury which closely underlines the nail bed and provides physical support to the nail bed along with correction of soft tissue injuries in the form of flaps or grafts, compounded by the repair or replacement of nail plate in the first 24 hours.

  15. Biomechanical evaluation of primary stiffness of tibiotalocalcaneal fusion with intramedullary nails.

    PubMed

    Mückley, Thomas; Eichorn, Stephan; Hoffmeier, Konrad; von Oldenburg, Geert; Speitling, Andreas; Hoffmann, Gunther O; Bühren, Volker

    2007-02-01

    Intramedullary implants are being used with increasing frequency for tibiotalocalcaneal fusion (TTCF). Clinically, the question arises whether intramedullary (IM) nails should have a compression mode to enhance biomechanical stiffness and fusion-site compression. This biomechanical study compared the primary stability of TTCF constructs using compressed and uncompressed retrograde IM nails and a screw technique in a bone model. For each technique, three composite bone models were used. The implants were a Biomet nail (static locking mode and compressed mode), a T2 femoral nail (compressed mode); a prototype IM nail 1 (PT1, compressed mode), a prototype IM nail 2 (PT2, dynamic locking mode and compressed mode), and a three-screw construct. The compressed contact surface of each construct was measured with pressure-sensitive film and expressed as percent of the available fusion-site area. Stiffness was tested in dorsiflexion and plantarflexion (D/P), varus and valgus (V/V), and internal rotation and external rotation (I/E) (20 load cycles per loading mode). Mean contact surfaces were 84.0 +/- 6.0% for the Biomet nail, 84.0 +/- 13.0% for the T2 nail, 70.0 +/- 7.2% for the PTI nail, and 83.5 +/- 5.5% for the compressed PT2 nail. The greatest primary stiffness in D/P was obtained with the compressed PT2, followed by the compressed Biomet nail. The dynamically locked PT2 produced the least primary stiffness. In V/V, PT1 had the (significantly) greatest primary stiffness, followed by the compressed PT2. The statically locked Biomet nail and the dynamically locked PT2 had the least primary stiffness in V/V. In I/E, the compressed PT2 had the greatest primary stiffness, followed by the PT1 and the T2 nails, which did not differ significantly from each other. The dynamically locked PT2 produced the least primary stiffness. The screw construct's contact surface and stiffness were intermediate. The IM nails with compression used for TTCF produced good contact surfaces and

  16. [Intramedullary nailing of the distal tibia illustrated with the Expert(TM) tibia nail].

    PubMed

    El Attal, R; Hansen, M; Rosenberger, R; Smekal, V; Rommens, P M; Blauth, M

    2011-12-01

    multicenter study. The follow-up rate was 81% after 1 year. Of these, 91 fractures (50.6%) were located in the distal third of the tibia. In this segment, the rate of delayed union was 10.6%. Malalignment of > 5° was observed in 5.4%. A secondary malalignment after initial good reduction was detected in only 1.1% of all cases. The implant-specific risk for screw breakage was 3.2%. One patient sustained a deep infection. If additional fibula plating was performed an 8-fold higher risk for delayed bone healing was observed (95%CI: 2.9-21.2, p< 0.001). If the fracture of the fibula was at the same height as on the tibia, the risk for delayed healing was even 14-fold (95% CI: 3.4-62.5, p< 0.001). Biomechanically plating of the fibula does not increase stability in suprasyndesmal distal tibia-fibular fractures treated with an intramedullary nail. Using the ETN with its optimized locking options, fibula plating is not recommended, thus, avoiding soft tissue problems and potentially delayed bone healing.

  17. Interlocking Intramedullary Nailing Versus Locked Dual-Plating Fixation for Femoral Shaft Fractures in Patients with Multiple Injuries: A Retrospective Comparative Study.

    PubMed

    Cheng, Tao; Xia, Rong-Gang; Dong, Shi-Kui; Yan, Xiao-Yu; Luo, Cong-Feng

    2017-12-18

    Intramedullary nailing (IMN) is a popular method in the management of femoral shaft fractures (FSFs). However, whether the association of IMN with pulmonary fat emboli can compromise the pulmonary and nervous systems is debatable. The purpose of this study is to compare IMN with the locked dual plating (LDP) method by assessing the clinical outcomes of FSF patients with head or chest injury. A total of 126 FSF patients were included in this study between January 2010 and July 2016 and divided into LDP and IMN groups. Patient demographic characteristics, operative time, blood loss, Harris Hip Score, Lysholm Knee Score, radiological outcomes, and systemic complications were collected and compared between the two treatment groups. Patients were followed up for at least 12 months. The LDP group performed better than IMN in terms of operative time, estimated blood loss amount, and malunion rate. Differences in function scores, fracture union rate, overall pulmonary complication rate, and in-hospital mortality between the two groups were not significant. Average radiographic union time was significantly longer in the LDP group (36.3 weeks) than in the IMN group (32.5 weeks). One case of fixation failure occurred postoperatively in the LDP group, whereas one case of fracture nonunion took place in the IMN group. Our findings suggest that dual-plating fixation is a promising method for FSFs with multiple injuries. However, the retrospective nature of this study necessitates high-quality trials to be performed to assess the clinical efficiency of dual plating.

  18. Angle-stable and compressed angle-stable locking for tibiotalocalcaneal arthrodesis with retrograde intramedullary nails. Biomechanical evaluation.

    PubMed

    Mückley, Thomas; Hoffmeier, Konrad; Klos, Kajetan; Petrovitch, Alexander; von Oldenburg, Geert; Hofmann, Gunther O

    2008-03-01

    Retrograde intramedullary nailing is an established procedure for tibiotalocalcaneal arthrodesis. The goal of this study was to evaluate the effects of angle-stable locking or compressed angle-stable locking on the initial stability of the nails and on the behavior of the constructs under cyclic loading conditions. Tibiotalocalcaneal arthrodesis was performed in fifteen third-generation synthetic bones and twenty-four fresh-frozen cadaver legs with use of retrograde intramedullary nailing with three different locking modes: a Stryker nail with compressed angle-stable locking, a Stryker nail with angle-stable locking, and a statically locked Biomet nail. Analyses were performed of the initial stability of the specimens (range of motion) and the laxity of the constructs (neutral zone) in dorsiflexion/plantar flexion, varus/valgus, and external rotation/internal rotation. Cyclic testing up to 100,000 cycles was also performed. The range of motion and the neutral zone in dorsiflexion/plantar flexion at specific cycle increments were determined. In both bone models, the intramedullary nails with compressed angle-stable locking and those with angle-stable locking were significantly superior, in terms of a smaller range of motion and neutral zone, to the statically locked nails. The compressed angle-stable nails were superior to the angle-stable nails only in the synthetic bone model, in external/internal rotation. Cyclic testing showed the nails with angle-stable locking and those with compressed angle-stable locking to have greater stability in both models. In the synthetic bone model, compressed angle-stable locking was significantly better than angle-stable locking; in the cadaver bone model, there was no significant difference between these two locking modes. During cyclic testing, five statically locked nails in the cadaver bone model failed, whereas one nail with angle-stable locking and one with compressed angle-stable locking failed. Regardless of the bone model

  19. Nail toxicity induced by cancer chemotherapy.

    PubMed

    Gilbar, Peter; Hain, Alice; Peereboom, Veta-Marie

    2009-09-01

    To provide a comprehensive literature review of chemotherapy-induced nail toxicity, including clinical presentation, implicated drugs and approaches for prevention and management. A search of MEDLINE and EMBASE (1966-2008) databases was conducted using the terms (and variations of the terms) antineoplastic agents, nails, nail toxicity, onycholysis, and paronychia. Bibliographies from selected articles were reviewed for appropriate references. The retrieved literature was reviewed to include all articles relevant to the clinical presentation, diagnosis, incidence, prevention, and treatment of chemotherapy-induced nail toxicity. Nail toxicity is a relatively uncommon adverse effect linked to a number of chemotherapeutic agents. Clinical presentation varies, depending on which nail structure is affected and the severity of the insult. Nail changes may involve all or some nails. Toxicity may be asymptomatic and limited to cosmetic concerns, however, more severe effects, involving pain and discomfort can occur. Taxanes and anthracyclines are the antineoplastic drug groups most commonly implicated. It is suggested that the administration schedule may influence the incidence of nail abnormalities, for example reported cases linked to the weekly administration of paclitaxel.Before instituting chemotherapy, patients should be educated regarding potential nail toxicities and strategies for prevention implemented. Management includes appropriate nail cutting, avoiding potential irritants, topical, or oral antimicrobials, and possibly cessation or dose reduction of the offending agent. Cryotherapy, through the application of frozen gloves or socks, has been beneficial in reducing docetaxel-induced nail toxicity and may be effective for other drugs.

  20. The effect of nail polish and acrylic nails on pulse oximetry reading using the Lifebox oximeter in Nigeria.

    PubMed

    Desalu, I; Diakparomre, O I; Salami, A O; Abiola, A O

    2013-12-01

    AIMS AND OBJECTIVES - Pulse oximetry is mandatory during anaesthesia, sedation and transfer of critically ill patients. The effect of nail polish and acrylic nails on the accuracy of saturation reading is inconsistent. The Lifebox pulse oximeter is reliable and recommended for low and middle income countries. We investigated its accuracy in the presence of 4 nail colours and acrylic nails SUBJECTS AND METHODS Fifty non-smoking volunteers had their fingers numbered from right to left (little finger of right hand =1 and little finger of left hand =10). Alternate fingers were nails painted with clear, red, brown and black nail polish and the 5th finger had acrylic nail applied. The corresponding finger on the other hand acted as control. The oxygen saturation was determined using the Lifebox pulse oximeter. Results All fingers (100%) with clear nail polish, red nail polish and acrylic nails recorded a saturation value. Each of the mean saturation value for clear nail polish, red nail polish and acrylic nails was not significantly different from the control mean (p= 0.378, 0.427 and 0.921). Only 12% and 64% of nails polished black and brown respectively recorded a saturation value. The mean SpO- for black and brown polish were significantly different from their control mean (p<0.001). CONCLUSION Black and brown polish resulted in a significant decrease in SpO with the Lifebox oximeter. Dark coloured nail polish should be removed prior to SpO2 determination to ensure that accurate readings can be obtained.

  1. The microvascular and morphostructural changes of nails in psoriatic patients with nail disease; a link between ultrasound and videocapillaroscopy findings in the nailfold.

    PubMed

    Bakirci Ureyen, Sibel; Kara, Rabia Oztas; Erturk, Zeynep; Yaldiz, Mahizer

    2018-05-02

    The objective of this study is to evaluate the link between nail fold vessel resistive index (NVRI) measured by ultrasound (US) and capillary loops diameters measured using nailfold videocapillarascopy (NVC), and to assess the morphological appearance of the nail bed in patients with psoriatic nail disease (PND) as compared with healthy controls (HCs). This study was conducted in patients with PND and HCs. General demographic data were collected and clinical assessments were performed for all subjects. The nail plate thickness (NPT) was measured on gray scale using US. The NVRI was measured using color Doppler (CD) US. The measurements of the apical, arterial, venous limb diameters and morpho-structural changes (tortuous, cross-linked capillaries) were assessed using NVC. Thirty-four patients with PND and 15 HCs were enrolled in this study. The two groups were matched for age and body mass index (BMI). Patients with PND had higher NPT and NVRI in comparison with HCs [(20 (17-23) vs 14 (14-15), p<0.001), (0.55 (0.51-0.61) vs 0.43 (0.38-0.49), p<0.001), respectively]. A higher proportion of patients with PND had tortuous capillaries than HCs (62% and 20% respectively, p=0.005). The mean NVRI was higher in patients with PND who had tortuous capillaries than patients who did not have tortuous capillaries (0.58 (0.7) and 0.52 (0.09), respectively p=0.033). Microvascular changes can be detected easily using non-invasive methods such as US and NVC. These methods can provide an objective data to better assess PND.

  2. Tibiotalocalcaneal arthrodesis with a retrograde intramedullary nail: a biomechanical analysis of the effect of nail length.

    PubMed

    Noonan, Timothy; Pinzur, Michael; Paxinos, Odysseas; Havey, Robert; Patwardhin, Avinash

    2005-04-01

    Fatigue fractures of the tibia have been observed at the level of the proximal end of the nail after successful tibiocalcaneal arthrodesis with a retrograde intramedullary device. To study the effect of nail length, five matched pairs of cadaver tibiae were instrumented with strain gauges and potted in methylmethacrylate from a level 3 cm proximal to the distal medial malleolus to simulate a successful tibiocalcaneal arthrodesis. A standard length (15 cm) ankle arthrodesis nail and an identical longer device terminating in the proximal tibial metaphysis were inserted in each paired tibia using appropriate technique. The strain of the posterior cortex of the tibia was recorded under bending moments of up to 50 Nm for each intact specimen after nail insertion and after proximal locking of the nail. The nails were then exchanged between the specimens of the same pairs and the experiment was repeated to insure uniformity. The standard length locked nail increased the principal strain of the posterior cortex of the tibia at the level of the proximal screw holes 5.3 times more than the locked long nail (353 and 67 microstrains), respectively. This stress concentration was not observed when the proximal extent of the nail terminated within the proximal tibial metaphysis. A successful tibiocalcaneal arthrodesis with a standard length locked intramedullary nail creates stress concentration around the proximal screw holes that may be responsible for the fractures observed clinically. This study supports the use of a "long" retrograde locked intramedullary nail for tibiocalcaneal arthrodesis in patients with systemic or localized osteopenia.

  3. Nail-Gun Injuries to the Hand

    PubMed Central

    Pierpont, Yvonne N.; Pappas-Politis, Effie; Naidu, Deepak K.; Salas, R. Emerick; Johnson, Erika L.; Payne, Wyatt G.

    2008-01-01

    Background: The nail gun is a commonly utilized tool in carpentry and construction. When used properly with appropriate safety precautions, it can facilitate production and boost efficiency; however, this powerful tool also has the potential to cause serious injury. The most common site of nail-gun injuries in both industrial and nonoccupational settings is the hand. Materials and Methods: We report on two patients with nail-gun injuries to the hand. A review of the literature and discussion of clinical evaluation and treatment of nail-gun injuries to the hand are presented. Results: Two patients present with soft tissue injuries to the hand with the nail embedded and intact at the injury site. Operative removal of the nail and wound care resulted in successful treatment in both cases. Nail-gun injuries to the hand vary in severity on the basis of the extent of structural damage. Treatment is based on the severity of injury and the presence and location of barbs on the penetrating nail. Conclusion: Healthcare providers must understand and educate patients on the prevention mechanics of nail-gun injuries. Nail-gun injuries to the hand necessitate appropriate evaluation techniques, understanding of surgical management versus nonsurgical management, and awareness of potential pitfalls in treatment. PMID:19079574

  4. Effect of mechanical forces on finger nail curvature: an analysis of the effect of occupation on finger nails.

    PubMed

    Sano, Hitomi; Shionoya, Kaori; Ogawa, Rei

    2014-04-01

    We studied the relationship between mechanical force and nail curvature. The effect of different frequencies and strengths of mechanical force on nail curvature was assessed. In Study 1, 63 carpenters and 63 office workers were enrolled, and the configurations of their thumb nails were assessed by measuring the curve index (defined as nail height/width) and pinch strength. In Study 2, nail curvature and pinch strength of jazz bassists, who characteristically do not use the right fourth and fifth fingers but use the left fifth finger a lot, were compared. In Study 3, the thumb nail curvature and pinch strength of the dominant and nondominant sides of the 126 participants from Study 1 were compared. Study 1: Carpenters had a significantly lower mean thumb nail curve index and higher mean pinch strength. Study 2: The nails of the unused right fourth and fifth fingers were much more curved than the nails of the frequently used left fourth and fifth fingers. The pinch strength of the right fifth finger was much weaker than the pinch strength of the left fifth finger. Study 3: The dominant side had a significantly lower nail curve index and higher pinch strength. The frequency and strength of mechanical forces on finger nails significantly affect nail appearance. © 2014 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  5. Revisiting Pneumatic Nail Gun Trigger Recommendations

    PubMed Central

    Albers, James; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-01-01

    Summary Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry. PMID:26366020

  6. Revisiting Pneumatic Nail Gun Trigger Recommendations.

    PubMed

    Albers, James; Lowe, Brian; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-03-01

    Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry.

  7. Impact of a healthy nails program on nail-biting in Turkish schoolchildren: a controlled pretest-posttest study.

    PubMed

    Ergun, Ayse; Toprak, Rumeysa; Sisman, Fatma Nevin

    2013-12-01

    This study was conducted to examine the effect of a healthy nails program on nail-biting in Turkish schoolchildren. This quasi-experimental study was of pretest-posttest control group design. A total of 50 students of a primary school formed the intervention group, while 53 students from the same school formed the control group. Data were collected with a demographic form, a nail-biting follow-up form, and photographs of the fingernails. It was found that 68.9% of students were biting seven or more of their nails; 46.6% had damaged nail beds. In the intervention group, the rate of the children who were not biting their nails (baseline = 0%, 4th week = 56.0%, 8th week = 64.0%) increased significantly compared to the control group (baseline = 0%, 4th week = 15.1%, 8th week = 18.9%). Outcomes indicate the efficacy of the healthy nails program in reducing the nail-biting problem in schoolchildren.

  8. [Comparison of clinical effects between anterior cervical Zero-incision fusion system and traditional nail plate system in the treatment of cervical spondylotic myelopathy].

    PubMed

    Chang, Bu-Qing; Feng, Hu; Yu, Chao-Jiang; Huang, Kai; Gao, Xiao; Tang, Hao; Jiang, Yun-Chang

    2017-05-25

    To compare the short-term efficacy of anterior cervical discectomy and fusion(ACDF) with traditional nail plate system and Zero-profile device in the treatment of cervical spondylotic myelopathy(CSM). The clinical data of 45 patients with CSM treated from July 2014 to August 2015 was retrospectively analyzed. There were 23 males and 22 females with an average age of 53.7 years old(range, 32 to 71 years old). The course of disease was 5 months to 2 years. All the patients were treated with ACDF with 24 cases by traditional nail plate system fixation(group A) and 21 cases by Zero-P system fixation(group B). Operation time and intraoperative bleeding were compared between two groups. Neurological function and cervical pain were evaluated by Japanese Orthopaedic Association scores (JOA) and visual analogue scale (VAS), respectively. Cervical curvature(Cobb angle) change and intervertebral fusion were evaluated by X-rays and CT. And associated complications were analyzed in two groups. All the patients were followed up for 12 to 16 months with an average of 14 months. Operation time of group A and B was(87.6±23.2) min and (62.7±17.3) min respectively, and the difference was significant between two groups; and intraoperative bleeding was (80.2±36.8) ml and (78.4±29.6) ml respectively, and the difference was not significant. At final follow-up, JOA and VAS of all patients were obvious improved, but there was no significant difference between two groups. Preoperative Cobb angle in group A and B was (8.7±4.3) ° and (8.6±4.2) ° respectively, and the difference was significant. The Cobb angle at final follow-up was (14.5±6.4) ° and (17.4±8.6) ° respectively, and the difference between two groups was significant. The incidence of dysphagia in group A and B were 29.17% and 9.52% respectively, and there was significant difference between two groups. All intervertebral spaces got fusion at final follow-up. No tracheo-asophageal injury and recurrent laryngeal nerve

  9. Tension Band Plating for Chronic Anterior Tibial Stress Fractures in High-Performance Athletes.

    PubMed

    Zbeda, Robert M; Sculco, Peter K; Urch, Ekaterina Y; Lazaro, Lionel E; Borens, Olivier; Williams, Riley J; Lorich, Dean G; Wellman, David S; Helfet, David L

    2015-07-01

    Anterior tibial stress fractures are associated with high rates of delayed union and nonunion, which can be particularly devastating to a professional athlete who requires rapid return to competition. Current surgical treatment strategies include intramedullary nailing, which has satisfactory rates of fracture union but an associated risk of anterior knee pain. Anterior tension band plating is a biomechanically sound alternative treatment for these fractures. Tension band plating of chronic anterior tibial stress fractures leads to rapid healing and return to physical activity and avoids the anterior knee pain associated with intramedullary nailing. Case series; Level of evidence, 4. Between 2001 and 2013, there were 13 chronic anterior tibial stress fractures in 12 professional or collegiate athletes who underwent tension band plating after failing nonoperative management. Patient charts were retrospectively reviewed for demographics, injury history, and surgical details. Radiographs were used to assess time to osseous union. Follow-up notes and phone interviews were used to determine follow-up time, return to training time, and whether the patient was able to return to competition. Cases included 13 stress fractures in 12 patients (9 females, 3 males). Five patients were track-and-field athletes, 4 patients played basketball, 2 patients played volleyball, and 1 was a ballet dancer. Five patients were Division I collegiate athletes and 7 were professional or Olympic athletes. Average age at time of surgery was 23.6 years (range, 20-32 years). Osseous union occurred on average at 9.6 weeks (range, 5.3-16.9 weeks) after surgery. Patients returned to training on average at 11.1 weeks (range, 5.7-20 weeks). Ninety-two percent (12/13) eventually returned to preinjury competition levels. Thirty-eight percent (5/13) underwent removal of hardware for plate prominence. There was no incidence of infection or nonunion. Anterior tension band plating for chronic tibial stress

  10. Nail disorders in infants and children.

    PubMed

    Piraccini, Bianca Maria; Starace, Michela

    2014-08-01

    Nail diseases in infants and children are an uncommon cause of consultation and are often difficult to diagnose and to manage. This review will cover nail diseases that are most commonly seen in clinical practice, including congenital and hereditary disorders and inflammatory, infective, and neoplastic nail diseases. The purpose of the review is to help the reader to recognize nail disorders at an early age and to manage them appropriately. Two recent large studies have reported the clinical findings of genetic disorders involving the nails, that is, pachyonychia congenita and epidermolysis bullosa. Only a few articles gave a comprehensive review of a disease, as occurred for onychomycosis, while the majority of the reports published in the recent literature involve single cases. Nail diseases in children and neonates are not easy to diagnose by nonexperts. Basic knowledge of the anatomy and biology of the nail facilitates their diagnosis as the understanding of their pathophysiology. This review gives hints at the most common nail diseases that affect infants and children.

  11. Intramedullary nailing in the treatment of aseptic tibial nonunion.

    PubMed

    Megas, P; Panagiotopoulos, E; Skriviliotakis, S; Lambiris, E

    2001-04-01

    Fifty patients suffering from aseptic tibial nonunion underwent reamed intramedullary nailing (I.N.) and were retrospectively reviewed. Thirty-six patients were initially treated with external fixation, six with plate and screws, one with a static I.N., and seven with plaster of Paris. Eighteen of the fractures were initially open (A: 5, B: 6, and C: 7 according to the Gustilo classification). In 34 cases a closed procedure was performed, whereas in sixteen, an opening at the nonunion site was unavoidable either to remove metalwork or realign the fragments. Following failed external fixation, secondary I.N. was performed at least 10 days after removal of the device. Bone grafts from the iliac crest were used in three cases, and a fibular osteotomy was performed in 33. Patients were followed up for an average of 2.5 years after nailing, ranging from 10 months to 7 years. A solid union was achieved in all patients within a period of 6 months. One patient developed late infection, which settled after nail removal and one patient developed impending compartment syndrome which was detected on the first post-operative day and was treated with a fasciotomy. Transient peroneal nerve palsy occurred in one patient and this recovered in 3 months, whereas in nine patients a clinically acceptable deformity was noticed. In conclusion, we believe that reamed intramedullary nailing is a highly effective treatment for aseptic tibial nonunions. Early and late complications are rare and bone graft is rarely needed. The method allows early weight bearing even before solid union occurs, short hospitalisation time and early return to work without external support.

  12. Knee arthrodesis with modular nail after failed TKA due to infection.

    PubMed

    Gallusser, Nicolas; Goetti, Patrick; Luyet, Anais; Borens, Olivier

    2015-12-01

    Knee arthrodesis is an established procedure for limb salvage after failed total knee arthroplasty (TKA) in cases of recurrent infection, soft tissue damage, reduced bone stock or with a deficient extensor mechanism. Walking with an arthrodesis is more efficient and less costly in terms of energy expenditure than above-knee amputation. Surgical options include an arthrodesis nail, external fixator or compression plate. We present our results of knee arthrodesis using the modular Wichita Fusion Nail(®) in patients after infected TKA. Fifteen patients with irretrievably failed TKA, due to infection, who underwent arthrodesis with the Wichita Fusion Nail(®) from 2004 to 2012 were retrospectively reviewed to assess fusion rate, time to fusion, complication rate, including new infections, and ambulatory status. Three patients were lost to follow-up. Mean follow-up was 33 months (6-132 months). At their most recent follow-up, all patients were walking with full weight bearing on a fused arthrodesis. Mean time to union was 9 months (3-29 months). Three patients necessitated a revision arthrodesis to achieve union after a mean of 5 months after the last procedure. Arthrodesis with the Wichita Fusion Nail(®) provides satisfactory results in patients with failure after infected TKA, with 75 % primary union rate and no new or persistent infection at last follow-up visit. Although burdened with a high complication rate, it represents an acceptable option for limb salvage in this particular pathology.

  13. A Biomechanical Assessment of Hand/Arm Force with Pneumatic Nail Gun Actuation Systems.

    PubMed

    Lowe, Brian D; Albers, James; Hudock, Stephen D

    2014-09-01

    A biomechanical model is presented, and combined with measurements of tip press force, to estimate total user hand force associated with two pneumatic nail gun trigger systems. The contact actuation trigger (CAT) can fire a nail when the user holds the trigger depressed first and then "bumps" the nail gun tip against the workpiece. With a full sequential actuation trigger (SAT) the user must press the tip against the workpiece prior to activating the trigger. The SAT is demonstrably safer in reducing traumatic injury risk, but increases the duration (and magnitude) of tip force exertion. Time integrated (cumulative) hand force was calculated for a single user from measurements of the tip contact force with the workpiece and transfer time between nails as inputs to a static model of the nail gun and workpiece in two nailing task orientations. The model shows the hand force dependence upon the orientation of the workpiece in addition to the trigger system. Based on standard time allowances from work measurement systems (i.e. Methods-Time Measurement - 1) it is proposed that efficient application of hand force with the SAT in maintaining tip contact can reduce force exertion attributable to the sequential actuation trigger to 2-8% (horizontal nailing) and 9-20% (vertical nailing) of the total hand/arm force. The present model is useful for considering differences in cumulative hand/arm force exposure between the SAT and CAT systems and may explain the appeal of the CAT trigger in reducing the user's perception of muscular effort.

  14. A Biomechanical Assessment of Hand/Arm Force with Pneumatic Nail Gun Actuation Systems

    PubMed Central

    Lowe, Brian D.; Albers, James; Hudock, Stephen D.

    2015-01-01

    A biomechanical model is presented, and combined with measurements of tip press force, to estimate total user hand force associated with two pneumatic nail gun trigger systems. The contact actuation trigger (CAT) can fire a nail when the user holds the trigger depressed first and then “bumps” the nail gun tip against the workpiece. With a full sequential actuation trigger (SAT) the user must press the tip against the workpiece prior to activating the trigger. The SAT is demonstrably safer in reducing traumatic injury risk, but increases the duration (and magnitude) of tip force exertion. Time integrated (cumulative) hand force was calculated for a single user from measurements of the tip contact force with the workpiece and transfer time between nails as inputs to a static model of the nail gun and workpiece in two nailing task orientations. The model shows the hand force dependence upon the orientation of the workpiece in addition to the trigger system. Based on standard time allowances from work measurement systems (i.e. Methods-Time Measurement - 1) it is proposed that efficient application of hand force with the SAT in maintaining tip contact can reduce force exertion attributable to the sequential actuation trigger to 2–8% (horizontal nailing) and 9–20% (vertical nailing) of the total hand/arm force. The present model is useful for considering differences in cumulative hand/arm force exposure between the SAT and CAT systems and may explain the appeal of the CAT trigger in reducing the user’s perception of muscular effort. PMID:26321780

  15. Application research of 3D additive manufacturing technology in the nail shell

    NASA Astrophysics Data System (ADS)

    Xiao, Shanhua; Yan, Ruiqiang; Song, Ning

    2018-04-01

    Based on the analysis of hierarchical slicing algorithm, 3D scanning of enterprise product nailing handle case file is carried out, point cloud data processing is performed on the source file, and the surface modeling and innovative design of nail handling handle case are completed. Using MakerBot Replicator2X-based 3D printer for layered 3D print samples, for the new nail product development to provide reverse modeling and rapid prototyping technical support.

  16. Using three-dimensional computational modeling to compare the geometrical fitness of two kinds of proximal femoral intramedullary nail for Chinese femur.

    PubMed

    Zhang, Sheng; Zhang, Kairui; Wang, Yimin; Feng, Wei; Wang, Bowei; Yu, Bin

    2013-01-01

    The aim of this study was to use three-dimensional (3D) computational modeling to compare the geometric fitness of these two kinds of proximal femoral intramedullary nails in the Chinese femurs. Computed tomography (CT) scans of a total of 120 normal adult Chinese cadaveric femurs were collected for analysis. With the three-dimensional (3D) computational technology, the anatomical fitness between the nail and bone was quantified according to the impingement incidence, maximum thicknesses and lengths by which the nail was protruding into the cortex in the virtual bone model, respectively, at the proximal, middle, and distal portions of the implant in the femur. The results showed that PFNA-II may fit better for the Chinese proximal femurs than InterTan, and the distal portion of InterTan may perform better than that of PFNA-II; the anatomic fitness of both nails for Chinese patients may not be very satisfactory. As a result, both implants need further modifications to meet the needs of the Chinese population.

  17. EPR spectroscopic investigation of psoriatic finger nails.

    PubMed

    Nakagawa, Kouichi; Minakawa, Satoko; Sawamura, Daisuke

    2013-11-01

    Nail lesions are common features of psoriasis and found in almost half of the patients. However, there is no feasible spectroscopic method evaluating changes and severity of nail psoriasis. EPR (electron paramagnetic resonance) might be feasible for evaluating nail conditions in the patients of psoriasis. Finger nails of five cases with nail psoriasis, (three females and two males) were examined. Nail samples were subjected to the EPR assay. The small piece of the finger nail (1.5 × 5 mm(2)) was incubated in ~50 μM 5-DSA (5-doxylstearic acid) aqueous solutions for about 60 min at 37°C. After rinsing and wiping off the excess 5-DSA solution, the nail samples were measured by EPR. EPR spectra were analyzed using the intensity ratio (Fast/Slow) of the two motions at the peaks of the lower magnetic field. We observed two distinguishable sites on the basis of the EPR results. In addition, the modern EPR calculation was performed to analyze the spectra obtained. The nail psoriasis-related region is 2~3 times higher than that of the control. The present EPR results show that there are two distinguishable sites in the nail. In the case of nail psoriasis, the fragile components are 2~3 times more than those of the control. Thus, the EPR method is thought to be a novel and reliable method of evaluating the nail psoriasis. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Dermoscopy of subungual haemorrhage: its usefulness in differential diagnosis from nail-unit melanoma.

    PubMed

    Mun, J-H; Kim, G-W; Jwa, S-W; Song, M; Kim, H-S; Ko, H-C; Kim, B-S; Kim, M-B

    2013-06-01

    Subungual haemorrhages are characterized by well-circumscribed dots or blotches with a red to red-black pigmentation, but some cases can be difficult to distinguish from subungual melanoma by the naked eye alone. Dermoscopy has proven to be a useful, noninvasive tool in the diagnosis of pigmented lesions in the nail; however, few dermoscopic studies of subungual haemorrhages have been reported. To investigate characteristic dermoscopic patterns of subungual haemorrhages, and to find distinctive features that can differentiate them from nail-unit melanomas. Patients with a confirmed diagnosis of either subungual haemorrhage or nail-unit melanoma at a tertiary university hospital were included in the study. Clinical features and dermoscopic patterns were evaluated. Sixty-four patients with a total of 90 lesions of subungual haemorrhage were enrolled in the study. The majority of cases (84%) showed combinations of more than one colour, while 16% had only one colour. The most common colour of the subungual haemorrhages was purple-black, in 37% of cases. A homogeneous pattern was observed in 92% of cases, globular patterns in 42% and streaks in 39%. Peripheral fading and periungual haemorrhages were found in 54% and 22% of cases, respectively. Destruction or dystrophy of the nail plate was observed in 16% of cases. In the 16 cases of nail-unit melanomas, Hutchinson sign, longitudinal irregular bands or lines, triangular shape of bands, vascular pattern, and ulcerations were found in 100%, 81%, 25%, 6% and 81% of cases, respectively. In contrast, these features were not found in subungual haemorrhages. Dermoscopy provides valuable information for the diagnosis of subungual haemorrhage and aids in the differential diagnosis from nail-unit melanoma. © 2013 The Authors. BJD © 2013 British Association of Dermatologists.

  19. Influence of the intramedullary nail preparation method on nail's mechanical properties and degradation rate.

    PubMed

    Morawska-Chochół, Anna; Chłopek, Jan; Szaraniec, Barbara; Domalik-Pyzik, Patrycja; Balacha, Ewa; Boguń, Maciej; Kucharski, Rafael

    2015-06-01

    When it comes to the treatment of long bone fractures, scientists are still investigating new materials for intramedullary nails and different manufacturing methods. Some of the most promising materials used in the field are resorbable polymers and their composites, especially since there is a wide range of potential manufacturing and processing methods. The aim of this work was to select the best manufacturing method and technological parameters to obtain multiphase, and multifunctional, biodegradable intramedullary nails. All composites were based on a poly(l-lactide) matrix. Either magnesium alloy wires or carbon and alginate fibres were introduced in order to reinforce the nails. The polylactide matrix was also modified with tricalcium phosphate and gentamicin sulfate. The composite nails were manufactured using three different methods: forming from solution, injection moulding and hot pressing. The effect of each method of manufacturing on mechanical properties and degradation rate of the nails was evaluated. The study showed that injection moulding provides higher uniformity and homogeneity of the particle-modified polylactide matrix, whereas hot pressing favours applying higher volume fractions of fibres and their better impregnation with the polymer matrix. Thus, it was concluded that the fabrication method should be individually selected dependently on the nail's desired phase composition. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Locking plate versus retrograde intramedullary nail fixation for tibiotalocalcaneal arthrodesis: A retrospective analysis

    PubMed Central

    Zhang, Chi; Shi, Zhongmin; Mei, Guohua

    2015-01-01

    Background: Tibiotalocalcaneal arthrodesis (TTCA) surgery is indicated for the end-stage disease of the tibiotalar and subtalar joints. Although different fixation technique of TTCA has been proposed to achieve high fusion rate and low complication rate, there is still no consensus upon this point. The purpose of this study is to compare the clinical efficacy of retrograde intramedullary nail fixation (RINF) and locking plate fixation (LPF) for TTCA. Materials and Methods: Fifty four patients who underwent TTCA through the lateral approach with lateral fibular osteotomy using RINF (32 patients, 18 male/14 female, mean age: 48) or LPF (22 patients, 12 male/10 female, mean age: 51) between January 2007 and January 2010 were retrospectively analyzed. Demographic and clinical characteristics, surgery (operation time, blood loss) outcomes (postoperative fusion rates, visual analog scale and foot and ankle surgery score and complications) were compared. Results: The LPF group had a shorter operation time (72.3 ± 9.2 vs. 102.8 ± 11.1 min, P < 0.001), less blood loss (75.9 ± 20.2 vs. 140.0 ± 23.8 ml, P < 0.001) and less intraoperative fluoroscopy sessions (3.6 ± 0.9 vs. 8.4 ± 1.3, P < 0.001) than the RINF group. Patients were followed up for 12–24 months (mean of 16.2 months). Both groups had similar postoperative fusion rates (90.6% and 95.4%) and the LPF group showed a nonsignificant lower complication rate (18.2% vs. 28.1% respectively). Patients at higher risk on nonunion due to rheumatoid diseases may have a lower nonunion rate with LPF than RINF (one out of eight vs. three out of nine, P < 0.001). Conclusions: The LPF for TTCA was simpler to perform compared with RINF, but with similar postoperative outcomes and complication rates. PMID:26015614

  1. Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia.

    PubMed

    Gupta, Anil; Anjum, Rashid; Singh, Navdeep; Hackla, Shafiq

    2015-04-01

    Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteosynthesis for the fibula as well. A common complication associated with dual plating is an increased chance of soft tissue necrosis, infection, and in some cases resulting in an exposed implant. We conducted a prospective study to analyze the results of fractures of the distal in both leg bones managed by the MIPPO procedure for tibial fractures and a rush nail for fibular fractures. The study was conducted in a tertiary care hospital from November 2012 to May 2014, a total of 30 fractures in 30 patients (18 males, 12 females) with a mean age of 42.4 years (26-60 years) were treated in our institution in the aforesaid time period with MIPPO for tibia and rush nail for fibular fractures. All the cases were operated on by a single surgeon in emergency within 24 hours. The patients with skin blistering and compound fractures were excluded from this study. Rehabilitative measures were proceeded as per patient's pain profile, isometric and isotonic exercises were started on the first post-operative day, with full weight bearing at 10-12 weeks after assessing clinical and radiological union. Regular follow up of patients was done, radiographs were taken at the immediate post-operative period and at 3, 6, 12 and 24 weeks. All the patients were available for regular follow up. Radiological and clinical union proceeded normally in all the patients, no patients had signs of any deep infection, delayed union or nonunion, three patients had a superficial infection of the tibial incision that healed with a change in antibiotic. The use of dual plating for fixation of the lower tibia and fibula

  2. Risk of symptomatic heterotopic ossification following plate osteosynthesis in multiple trauma patients: an analysis in a level-1 trauma centre

    PubMed Central

    Zeckey, Christian; Hildebrand, Frank; Mommsen, Philipp; Schumann, Julia; Frink, Michael; Pape, Hans-Christoph; Krettek, Christian; Probst, Christian

    2009-01-01

    Background Symptomatic heterotopic ossification (HO) in multiple trauma patients may lead to follow up surgery, furthermore the long-term outcome can be restricted. Knowledge of the effect of surgical treatment on formation of symptomatic heterotopic ossification in polytrauma is sparse. Therefore, we test the effects of surgical treatment (plate osteosynthesis or intramedullary nailing) on the formation of heterotopic ossification in the multiple trauma patient. Methods We retrospectively analysed prospectively documented data of blunt multiple trauma patients with long bone fractures which were treated at our level-1 trauma centre between 1997 and 2005. Patients were distributed to 2 groups: Patients treated by intramedullary nails (group IMN) or plate osteosynthesis (group PLATE) were compared. The expression and extension of symptomatic heterotopic ossifications on 3-6 months follow-up x-rays in antero-posterior (ap) and lateral views were classified radiologically and the maximum expansion was measured in millimeter (mm). Additionally, ventilation time, prophylactic medication like indomethacine and incidence and correlation of head injuries were analysed. Results 101 patients were included in our study, 79 men and 22 women. The fractures were treated by intramedullary nails (group IMN n = 50) or plate osteosynthesis (group PLATE n = 51). Significantly higher radiologic ossification classes were detected in group PLATE (2.9 ± 1.3) as compared to IMN (2.2 ± 1.1; p = 0.013). HO size in mm ap and lateral showed a tendency towards larger HOs in the PLATE group. Additionally PLATE group showed a higher rate of articular fractures (63% vs. 28% in IMN) while IMN demonstrated a higher rate of diaphyseal fractures (72% vs. 37% in PLATE; p = 0.003). Ventilation time, indomethacine and incidence of head injuries showed no significant difference between groups. Conclusion Fracture care with plate osteosynthesis in polytrauma patients is associated with larger formations

  3. Genetics Home Reference: nonsyndromic congenital nail disorder 10

    MedlinePlus

    ... Nails MalaCards: nail disorder, nonsyndromic congenital, 10 Merck Manual Consumer Version: Deformities, Dystrophies, and Discoloration of the Nails Orphanet: Autosomal recessive nail dysplasia Patient Support ...

  4. Finite Element Analysis of Absorbable Sheath to Prevent Stress Shielding of Tibial Interlocking Intramedullary Nail

    NASA Astrophysics Data System (ADS)

    Dong, Yansheng; Wang, Yongqing; Dong, Limin; Jia, Peng; Lu, Fengcheng

    2017-07-01

    The nail with absorbable sheath (AS nail) is designed to reduce the stress shielding effect of internal fixation with interlocking intramedullary nail. In order to verify its feasibility, two types of the finite element models of internal fixation of tibia with the AS nail and the common metal nail (CM nail) are established using the Softwares of Mimics, Geomagic, SolidWorks and ANSYS according to the CT scanning data of tibia. The result of the finite element analysis shows that the AS nail has great advantages compared with the CM nail in reducing the stress shielding effect in different periods of fracture healing. The conclusion is that the AS nail can realize the static fixation to the dynamic fixation from the early to the later automatically to shorten the time of fracture healing, which also provides a new technique to the interlocking intramedullary nail.

  5. UK Fixation of Distal Tibia Fractures (UK FixDT): protocol for a randomised controlled trial of ‘locking’ plate fixation versus intramedullary nail fixation in the treatment of adult patients with a displaced fracture of the distal tibia

    PubMed Central

    Achten, Juul; Parsons, Nicholas R; McGuinness, Katie R; Petrou, Stavros; Lamb, Sarah E; Costa, Matthew L

    2015-01-01

    Introduction The treatment of displaced, extra-articular fractures of the distal tibia remains controversial. These injuries are difficult to manage due to limited soft tissue cover, poor vascularity of the area and proximity to the ankle joint. Surgical treatment options are expanding and include locked intramedullary nails, plate and screw fixation and external fixator systems. The nail and plate options are most commonly used in the UK, but controversy exists over which treatment is most clinically and cost-effective. In this multicentre randomised controlled trial we aim to assess ratings of disability 6 months postinjury in patients who have sustained a distal tibia fracture treated with either an intramedullary nail or plate and locking screw fixation. Methods and analysis Adult patients presenting at trial centres with an acute fracture of the distal tibia will be considered for inclusion. A total of 320 patients will provide 90% power to detect a difference of 8 points in Disability Rating Index (DRI) score at 6 months at the 5% level. The randomisation sequence is stratified by trial centre and age, and administered via web-based service with 1:1 treatment allocation. Baseline demographic and pre-injury functional data and radiographs will be collected using the DRI, Olerud and Molander, and EuroQol EQ-5D questionnaire. Clinical assessment, early complications and radiographs will be recorded at 6–8 weeks. Functional outcome, health-related quality of life and resource use will be collected at 3, 6 and 12 months postoperatively. The main analysis will investigate differences in DRI 6 months postsurgery, between the two treatment groups, on an intention-to-treat basis. Tests will be two-sided and considered to provide evidence for a significant difference if p values are <0.05. Ethics and dissemination NRES Committee West-Midlands, 6/11/2012 (ref:12/WM/0340). The results of the trial will be disseminated via peer-reviewed publications and

  6. Are there any advantages in using a distal aiming device for tibial nailing? Comparing the Centro Nailing System with the Unreamed Tibia Nail.

    PubMed

    Veen, Egbert J D; Ettema, Harmen B; Zuurmond, Rutger G; Mostert, Adriaan K

    2011-10-01

    The distal locking of an intramedullary tibial nail can be challenging and time consuming when performed freehand. This study was conducted to evaluate if a distal aiming device would reduce surgical time. A case-controlled study was performed between 2007 and 2009 with 30 patients receiving a reamed tibial nail (Centronail) with the use of a distal aiming device and 30 patients who were treated with an Unreamed Tibia Nail (UTN), with freehand distal locking, in the same period. The primary outcome in this study was operative time. Secondary outcomes were the need for fluoroscopy, time to consolidation and complications. Operation time was longer in the Centronail group compared with the UTN group (126 min vs. 96 min, p=0.000). Use of fluoroscopy for distal locking was needed in half of the cases (n=16) using a distal aiming device. No differences were found regarding time to consolidation, time to removal of the nail and complications. The use of an aiming device for distal locking of a tibia nail lengthens operation time rather than reducing it. Fluoroscopy was still needed in about half of the cases. No difference was seen in clinical outcomes. The use of a distal aiming device to lock a tibial nail appears to have no benefit. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Nail tic disorders: Manifestations, pathogenesis and management.

    PubMed

    Singal, Archana; Daulatabad, Deepashree

    2017-01-01

    Nail tic disorders are classic examples of overlap between the domains of dermatology and psychiatry. They are examples of body-focused repetitive behaviors in which there is an irresistible urge or impulse to perform a certain behavior. The behavior is reinforced as it results in some degree of relief and pleasure. Nail tic disorders are common, yet poorly studied and understood. The literature on nail tic disorders is relatively scarce. Common nail tics include nail biting or onychophagia, onychotillomania and the habit tic deformity. Some uncommon and rare nail tic disorders are onychoteiromania, onychotemnomania, onychodaknomania and bidet nails. Onychophagia is chronic nail biting behavior which usually starts during childhood. It is often regarded as a tension reducing measure. Onychotillomania is recurrent picking and manicuring of the fingernails and/or toenails. In severe cases, it may lead to onychoatrophy due to irreversible scarring of the nail matrix. Very often, they occur in psychologically normal children but may sometimes be associated with anxiety. In severe cases, onychotillomania may be an expression of obsessive-compulsive disorders. Management of nail tic disorders is challenging. Frequent applications of distasteful topical preparations on the nail and periungual skin can discourage patients from biting and chewing their fingernails. Habit-tic deformity can be helped by bandaging the digit daily with permeable adhesive tape. Fluoxetine in high doses can be helpful in interrupting these compulsive disorders in adults. For a complete diagnosis and accurate management, it is imperative to assess the patient's mental health and simultaneously treat the underlying psychiatric comorbidity, if any.

  8. [Tibio-talo-calcaneal arthrodesis with the retrograde intramedullary nail MEDIN].

    PubMed

    Popelka, S; Vavřík, P; Landor, I; Bek, J; Popelka ml, S; Hromádka, R

    2013-01-01

    When the talus and the talocalcaneal joint are both affected, their fusion is the method of treatment. Ankle arthrodesis is carried out using various osteosynthetic materials such as external fixators, screws and plates. One of the options is retrograde nailing. Tibio-talo-calcaneal arthrodesis is frequently indicated in patients with rheumatoid arthritis (RA) in whom both the talus and the subtalar joint are often affected. A retrograde nail for tibio-talo-calcaneal arthrodesis was developed at our department in cooperation with MEDIN Company. This is a titanium double-curved nail, with the distal part bent at 8 degrees ventrally and 10 degrees laterally. It is inserted from the transfibular approach. Sixty-two patients, 35 women and 27 men, were treated at our department from 2005. Since one patient had bilateral surgery, 63 ankles were included. The indications for arthrodesis involved rheumatoid arthritis in 42, post-traumatic arthritis in 10, failed ankle arthrodesis in two and failed total ankle arthroplasty in five ankles; tibial stress fractures close above the ankle in two RA patients, one patient with dermatomyositis and one with lupus erythematodes. The average age at the time of surgery was 64.2 years (range, 30 to 80). The average follow-up was 4.5 years (range, 1 to 9 years), Satisfaction with the treatment outcome and willingness to undergo surgery on the other side were reported by 82% of the patients. The AOFAS score improved from 35 to 74 points. Three (4.8%) patients complained of painful feet due to the fact that exact correction of the calcaneus was not achieved and the heel after arthrodesis remained in a slightly varus position. Of them, two had a failed total ankle arthroplasty. Post-operative complications included early infection managed by antibiotic treatment and early surgical revision with irrigation.in two (3.2%) RA patients, who were undergoing biological therapy. Late infection developed at 2 to 3 years after surgery in three (4

  9. Pulmonary fat embolism after reamed and unreamed nailing of femoral fractures.

    PubMed

    Högel, F; Gerlach, U V; Südkamp, N P; Müller, C A

    2010-12-01

    To determine whether reamed or unreamed intramedullary nailing of femoral fractures results in higher incidence of pulmonary fat embolism, three different methods of intramedullary nailing were compared in sheep. To analyze the presence of bone marrow fat embolism in pulmonary arteries, histological evaluation was undertaken using a quantitative computer-assisted measurement system. In this experimental model of 27 female Swiss alpine sheep, an osteotomy of the proximal femur was conducted in each animal. Then, the animals were divided into three groups according to the method of treatment: two different reamed intramedullary nailing techniques and an unreamed nailing technique were used. In the first group "ER" (experimental reamer; n=9), the nail was inserted after reaming with an experimental reamer; in the second group "CR" (conventional reamer; n=7), the intramedullary nail was inserted after reaming with the conventional AO-reamer. In the third group "UN" (unreamed; n=8) unreamed nailing was performed. During the operation procedure intramedullary pressure was measured in the distal fragment. After sacrificing the animals, quantitative histological analyses of bone marrow fat embolism in pulmonary arteries were done using osmium tetroxide fixation and staining of the fat. The measurement of intramedullary pressure showed significantly lower values for reamed nailing than for the unreamed technique. The quantitative histological evaluation of lung vessels concerning bone marrow fat embolism revealed a statistically significant difference between reamed and unreamed insertion of the nail: 7.77%±6.93 (ER) and 6.66%±5.61 (CR) vs. 16.25%±10.05 (UN) (p<0.05) of the assessed lung vessels were filled with fat emboli. However, no difference was found between the traditional and experimental reamer. Intramedullary nailing after reaming is a safe procedure with low systemic embolisation when compared to the unreamed insertion of the nail. Copyright © 2010 Elsevier

  10. The nail and hair in forensic science.

    PubMed

    Daniel, C Ralph; Piraccini, Bianca Maria; Tosti, Antonella

    2004-02-01

    Drugs, chemicals, and biological substances accumulate and are stored in hair and nails where they can be detected and measured. Advantages of analyzing hair and nail samples also include their easy and non-invasive collection, the small sample size required for analysis, and their easy storage at room temperature. We report 3 examples of heavy metal poisoning diagnosed because of the hair or nail symptoms. Drugs and toxins that can be detected in hair and nails are reviewed and the application of hair/nail analysis in general and in forensic medicine is discussed.

  11. Review of end grain nail withdrawal research

    Treesearch

    Douglas R. Rammer; Samuel L. Zelinka

    2004-01-01

    This study reviewed the literature on static and impact withdrawal of nails driven into the end grain of wood members. From this, an empirical relationship was created relating the specific gravity of the wood, the diameter of the nail, and the depth of penetration of the nail to the static withdrawal capacity of nails driven into the wood and withdrawn immediately....

  12. Is there a bone-nail specific entry point? Automated fit quantification of tibial nail designs during the insertion for six different nail entry points.

    PubMed

    Amarathunga, J P; Schuetz, M A; Yarlagadda, K V D; Schmutz, B

    2015-04-01

    Intramedullary nailing is the standard fixation method for displaced diaphyseal fractures of tibia. Selection of the correct nail insertion point is important for axial alignment of bone fragments and to avoid iatrogenic fractures. However, the standard entry point (SEP) may not always optimise the bone-nail fit due to geometric variations of bones. This study aimed to investigate the optimal entry for a given bone-nail pair using the fit quantification software tool previously developed by the authors. The misfit was quantified for 20 bones with two nail designs (ETN and ETN-Proximal Bend) related to the SEP and 5 entry points which were 5 mm and 10 mm away from the SEP. The SEP was the optimal entry point for 50% of the bones used. For the remaining bones, the optimal entry point was located 5 mm away from the SEP, which improved the overall fit by 40% on average. However, entry points 10 mm away from the SEP doubled the misfit. The optimised bone-nail fit can be achieved through the SEP and within the range of a 5 mm radius, except posteriorly. The study results suggest that the optimal entry point should be selected by considering the fit during insertion and not only at the final position. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. A cranial nail for fetal shunting.

    PubMed

    Saunders, R L; Simmons, G M; Edwards, W H; Crow, H C

    1985-01-01

    A small number of human fetal hydrocephalics have been treated by ventriculoamniotic shunts of silastic tubing. The Colorado device appears to be the one most commonly used. The original experimental device tested on a primate model resembled a hollow shingle nail. This was designed by Michedja and Hodgen, contained a spring valve, measured approximately 32 X 4 mm and was placed by hysterotomy. An attractive feature of this design was its fixation by impaction in the skull, preventing displacement by fetal activity, a reported disadvantage with the silastic devices. To our knowledge, no one has used this nail-like design and tailored it to transuterine percutaneous placement in a human case.

  14. Intramedullary nailing: experience in 427 patients.

    PubMed

    Lambiris, E; Tyllianakis, M; Megas, P; Panagiotopoulos, E

    1996-01-01

    In the Orthopaedic Department in Patras University 427 intramedullary nailings in the lower limbs were performed between 1989 and 1994 and retrospectively reviewed to evaluate the range of complications. One hundred and seventy-two were nailings of the femur; 80 gamma nails mainly for subtrochanteric and intertrochanteric with subtrochanteric extension fractures were included, (total 252/59%); 175 (41%) were nailings of the tibia. Union was achieved in all case. Overall the complication rate in this series was 3.3% (14 cases) and included infection (4 cases), neuropraxia (2 cases), implant failure (5 cases), limb length deficiency (2 cases) and malrotation (1 case).

  15. In Vivo Caprine Model for Osteomyelitis and Evaluation of Biofilm-Resistant Intramedullary Nails

    PubMed Central

    Tran, Nhiem; Tran, Phong A.; Jarrell, John D.; Engiles, Julie B.; Thomas, Nathan P.; Young, Matthew D.; Hayda, Roman A.; Born, Christopher T.

    2013-01-01

    Bone infection remains a formidable challenge to the medical field. The goal of the current study is to evaluate antibacterial coatings in vitro and to develop a large animal model to assess coated bone implants. A novel coating consisting of titanium oxide and siloxane polymer doped with silver was created by metal-organic methods. The coating was tested in vitro using rapid screening techniques to determine compositions which inhibited Staphylococcus aureus growth, while not affecting osteoblast viability. The coating was then applied to intramedullary nails and evaluated in vivo in a caprine model. In this pilot study, a fracture was created in the tibia of the goat, and Staphylococcus aureus was inoculated directly into the bone canal. The fractures were fixed by either coated (treated) or non-coated intramedullary nails (control) for 5 weeks. Clinical observations as well as microbiology, mechanical, radiology, and histology testing were used to compare the animals. The treated goat was able to walk using all four limbs after 5 weeks, while the control was unwilling to bear weight on the fixed leg. These results suggest the antimicrobial potential of the hybrid coating and the feasibility of the goat model for antimicrobial coated intramedullary implant evaluation. PMID:23841085

  16. Failure analysis of knee arthrodesis with the WichitaFusion Nail.

    PubMed

    Parcel, Ted W; Levering, Melissa; Polikandriotis, John A; Gustke, Kenneth A; Bernasek, Thomas L

    2013-11-01

    Arthrodesis is a salvage procedure for failed total knee arthroplasty with the intent to create a stable, pain-free limb on which to ambulate or transfer. For many patients, the alternative to arthrodesis may be an above-knee amputation. Available techniques for knee arthrodesis include compression plating, external fixators, and intramedullary fixation. The purpose of this study was to report the knee fusion rate of consecutive patients at 1 institution using an intramedullary fusion nail and to identify patient risk factors for fusion failure. Between November 1998 and November 2008, twenty-eight patients undergoing knee arthrodesis with an average follow-up of 18 months (range, 3-64 months) were retrospectively studied. Demographic information, presence of fusion, clinical function, pain level, and bone defect data were collected and analyzed. Eighty-two percent (23/28) of patients had radiographic evidence of successful fusion with an average time to fusion of 21 weeks (range, 10-58 weeks). When examining patient variables that could correlate with fusion rates, patients with an Anderson Orthopaedic Research Institute type 3 femoral or type 3 tibial defect had a statistically significant lower fusion rate. The intramedullary fusion nail is an effective device for knee arthrodesis that offers ease of insertion through the knee wound with the advantages of initial bone compression and rigid fixation. Although the use of intramedullary fusion nails leads to a high fusion rate, significant bone deficiency limits successful fusion. Copyright 2013, SLACK Incorporated.

  17. Nail gun injuries among construction workers.

    PubMed

    Dement, John M; Lipscomb, Hester; Li, Leiming; Epling, Carol; Desai, Tejas

    2003-05-01

    Pneumatic nail guns greatly increase worker productivity and are extensively used in wood frame building construction, with especially high use in residential construction. One surveillance report of nail gun injuries in Washington State has been published; however, other literature consists largely of case reports and case series in trauma journals. The major objective of the current study was to investigate the occurrence of nail gun-associated injuries among construction workers and to identify preventable work-related factors associated with these injuries. Nail gun-related injuries occurring among a cohort of 13,347 carpenters in Ohio who worked union hours during the time period January 1, 1994, until September 30, 1997, were identified by matching the cohort with workers' compensation claims made to the Ohio Bureau of Workers' Compensation. We also analyzed workers' compensation claims for North Carolina Home Builders Association members for the period July 1996-November 1999 to identify nail gun-related injuries. Analyses included stratified analyses of claims by nature and body part injured, calculation of nail gun injury rates, and analyses of free text descriptions of injuries. Overall, nail gun injuries were responsible for 3.9 percent of workers' compensation claims with 8.3 percent to 25.5 percent of claims involving paid lost work time. The overall rate of nail gun injuries (cases per 200,000 work hours) was 0.33 in North Carolina and 0.26 in Ohio, reflecting the greater concentration of wood frame construction workers in the North Carolina population studied. Higher rates of injury were observed for carpenters in North Carolina and among residential carpenters in Ohio. The predominant body part injured was the hands/fingers, with 80 to 89 percent of injuries being nail punctures. Analyses of free text information for puncture injuries found approximately 70 percent of injuries to occur during the framing/sheathing stage of construction. Our data

  18. Arthrodesis of the knee: experience with intramedullary nailing.

    PubMed

    Incavo, S J; Lilly, J W; Bartlett, C S; Churchill, D L

    2000-10-01

    Knee arthrodesis using an intramedullary nail has gained acceptance as treatment in difficult cases such as infection after total knee arthroplasty (TKA), neuropathic joint, and obesity. A retrospective review of 22 cases treated at our institution using an intramedullary nail for knee arthrodesis was performed. Deep infection after primary (11) or revision (6) TKA was the most common indication for this procedure. A long intramedullary nail was used in 3 cases, a long nail with a proximal interlocking screw was used in 6 cases, and a customized nail with a valgus bend and a proximal interlocking screw was used in 11 cases. A modular knee fusion nail was used in 1 case. Successful fusion occurred in all cases, although 4 patients required additional surgery. Average operative blood loss was 748 mL, and average time to union was 7 months. Shortening of the extremity averaged 3.2 cm. Tibiofemoral alignment was improved by using a customized valgus nail (average, 3.1 valgus; range, 1-5) when compared with a straight nail (average, 0.2 valgus; range, 3 varus to 3 valgus). No patient developed infection in the hip or ankle region as a result of the long intramedullary nail. Intramedullary nailing is an excellent technique for knee arthrodesis in difficult cases. A customized proximal interlocking nail with 5 degrees to 7 degrees of valgus and 5 degrees of anterior angulation improves tibiofemoral alignment and is straightforward to insert or extract should it be necessary. Stability and pain relief are rapid, and the fusion rate is maximized.

  19. [Treatment of calcaneal fractures with a locking nail (C-Nail)].

    PubMed

    Pompach, M; Carda, M; Amlang, M; Zwipp, H

    2016-06-01

    Anatomic reconstruction of the posterior facet by primary stabilization of the calcaneal fracture with a locking nail. All intraarticular calcaneal fractures and unstable two-part fractures independent of the degree of closed/open soft tissue trauma. High perioperative risk, soft tissue infection, beak fracture (type II fracture) and still open apophysis. Anatomic reduction of the posterior facet using a sinus tarsi approach. Reduction and temporary fixation of the sustentacular, tuberosity, and anterior process fragments with 1.8-2.0 mm Kirschner wires. Thereafter, the C-Nail (calcaneus nail) is introduced with its guiding device stabilizing the sustentacular, tuberostity, and anterior process fragments through its three guiding arms with 6 or 7 locking screws. Passive and active motion starts on postoperative day 2. Lymph drains help reduce swelling. Partial weightbearing with 20 kg for 6-8 weeks in the patient's own shoes is recommended. X‑ray controls are done at 4 and 8 weeks as well as after 6 and 12 months. A total of 107 calcaneal fractures treated with the C-Nail between 2011 and 2014 were evaluated according to the AOFAS score 6 months and 1 year after surgery. The measured values were on average 93.0 (range 65-100) points at 6 months and 94.1 (range 75-100) points 12 months after the surgery. Böhler's angle with initial traumatic values of 6.2° (-30 to +13°) improved postoperatively to 31.8°, after 3 months slightly decreased to 29.6°, and after 12 months to 28.3°. There were 2 cases of superficial wound necrosis (1.9 %) and 1 case a deep infection (0.93 %) with need of early C-Nail removal.

  20. Efalizumab in the Treatment of Scalp, Palmoplantar and Nail Psoriasis: Results of a 24-Week Latin American Study

    PubMed Central

    Takahashi, María Denise; Chouela, Edgardo Néstor; Dorantes, Gladys Leon; Roselino, Ana Maria; Santamaria, Jesùs; Allevato, Miguel Angel; Cestari, Tania; de Aillaud, Maria Eugenia Manzanera; Stengel, Fernando Miguel; Licu, Daiana

    2010-01-01

    Introduction Plaque-type psoriasis affecting the nails, scalp, hands or feet can often be difficult to treat; for example, topical treatments and phototherapy may not penetrate the nail plate or scalp. The objective of this large, international, multicentre study was to investigate the efficacy of efalizumab in a Latin American population of adult patients with moderate-to-severe chronic plaque psoriasis who were candidates for systemic therapy or phototherapy. Methods Eligible patients were enrolled in a 24-week, open-label, single-arm, Phase IIIb/IV study of continuous treatment with subcutaneous efalizumab, 1.0 mg/kg/wk. Involvement of the nails, scalp, or hands or feet was assessed using the Nail Psoriasis Severity Index (NAPSI), the Psoriasis Scalp Severity Index (PSSI), or the Palmoplantar Pustulosis Psoriasis Area and Severity Index (PPPASI), respectively. Missing data were handled using a last observation carried forward or nonresponder imputation approach. Results Of the 189 patients who received treatment, 112 patients had nail involvement, 172 had scalp involvement, and 19 had palmoplantar disease at baseline. At Week 24, ≥50% improvement on the NAPSI, PSSI and PPPASI was observed in 31%, 71% and 68% of patients, respectively, whereas ≥75% improvement on these scores was observed in 17%, 52% and 63%, respectively. Descriptive statistics showed lower NAPSI-75 and higher PSSI-75 and -50 response rates among patients with higher baseline scores. Conclusions This open-label, uncontrolled study provides supportive evidence of the potential of efalizumab as a treatment for nail, scalp and palmoplantar psoriasis. PMID:20428227

  1. Tibiotalocalcaneal arthrodesis with a compressive retrograde intramedullary nail: a report of 34 consecutive patients.

    PubMed

    Niinimäki, Tuukka Timo; Klemola, Tero-Matti; Leppilahti, Juhana Ilmari

    2007-04-01

    Tibiotalocalcaneal arthrodesis is a treatment modality for severe arthrosis and malalignment of the hindfoot. Complications, such as delayed union and nonunion, are well-known risks of the procedure. Arthrodesis can be done with a plate, screws, an external fixator, or an intramedullary nail. Compression with an intramedullary nail was the focus of this report. Thirty-four consecutive patients (23 men and 11 women) with an average age range of 57 (range 25-77) years had tibiotalocalcaneal arthrodesis using retrograde intramedullary compression nail fixation. Mean followup was 24 (range 6 to 43) months. One patient died of an unrelated cause, but 30 (91%) of the remaining 33 patients answered the questionnaire. Bony consolidation was achieved in 26 (76%) patients, the mean time to fusion being 16 weeks. Five patients (15%) had complications and seven (20%) had repeat surgery. Of the 30 patients who responded to the questionnaire, three patients (10%) evaluated the overall result subjectively as being of no benefit and 27 (90%) as improved. The visual analog scale (VAS) score for preoperative pain was 66 at rest and 83 when walking, and the mean postoperative scores were 19 and 32, respectively (p<0.001). Tibiotalocalcaneal arthrodesis with a compressive retrograde intramedullary nail is an effective and safe procedure for patients with severe malalignment or arthrosis of the hindfoot. It is essentially a salvage procedure, and most patients benefit from it, but excellent results are rare.

  2. Tibiotalocalcaneal Arthrodesis Nails: A Comparison of Nails With and Without Internal Compression.

    PubMed

    Taylor, James; Lucas, Douglas E; Riley, Aimee; Simpson, G Alex; Philbin, Terrence M

    2016-03-01

    Hindfoot arthrodesis with tibiotalocalcaneal (TTC) intramedullary nails is used commonly when treating ankle and subtalar arthritis and other hindfoot pathology. Adequate compression is paramount to avoid nonunion and fatigue fracture of the hardware. Arthrodesis systems with internal compression have demonstrated superior compression to systems relying on external methods. This study examined the speed of union with TTC fusion nails with internal compression over nails without internal compression. A retrospective review was performed identifying nail type and time to union of the subtalar joint (STJ) and tibiotalar joint (TTJ). A total of 198 patients were included from 2003 to 2011. The median time to STJ fusion without internal compression was 104 days compared to 92 days with internal compression (P = .044). The median time to TTJ fusion without internal compression was 111 days compared to 93 days with internal compression (P = .010). Adjusting for diabetes, there was no significant difference in fusion speed with or without internal compression for the STJ (P = .561) or TTJ (P = .358). Nonunion rates were 24.5% for the STJ and 17.0% for the TTJ with internal compression, and 43.4% for the STJ and 42.1% for the TTJ without internal compression. This difference remained statistically significant after adjusting for diabetes for the TTJ (P = .001) but not for the STJ (P = .194). The intramedullary hindfoot arthrodesis nail was a viable treatment option in degenerative joint disease of the TTC joint. There appeared to be an advantage using systems with internal compression; however, there was no statistically significant difference after controlling for diabetes. Level III, retrospective comparative series. © The Author(s) 2015.

  3. A patient specific finite element simulation of intramedullary nailing to predict the displacement of the distal locking hole.

    PubMed

    Mortazavi, Javad; Farahmand, Farzam; Behzadipour, Saeed; Yeganeh, Ali; Aghighi, Mohammad

    2018-05-01

    Distal locking is a challenging subtask of intramedullary nailing fracture fixation due to the nail deformation that makes the proximally mounted targeting systems ineffective. A patient specific finite element model was developed, based on the QCT data of a cadaveric femur, to predict the position of the distal hole of the nail postoperatively. The mechanical interactions of femur and nail (of two sizes) during nail insertion was simulated using ABAQUS in two steps of dynamic pushing and static equilibrium, for the intact and distally fractured bone. Experiments were also performed on the same specimen to validate the simulation results. A good agreement was found between the model predictions and the experimental observations. There was a three-point contact pattern between the nail and medullary canal, only on the proximal fragment of the fractured bone. The nail deflection was much larger in the sagittal plane and increased for the larger diameter nail, as well as for more distally fractured or intact femur. The altered position of the distal hole was predicted by the model with an acceptable error (mean: 0.95; max: 1.5 mm, in different tests) to be used as the compensatory information for fine tuning of proximally mounted targeting systems. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Nails in Forensic Toxicology: An Update.

    PubMed

    Solimini, Renata; Minutillo, Adele; Kyriakou, Chrystalla; Pichini, Simona; Pacifici, Roberta; Busardo, Francesco Paolo

    2017-01-01

    The analysis of nails as a keratinized matrix to detect drugs or illicit substances has been increasingly used in forensic and clinical toxicology as a complementary test, especially for the specific characteristics of stably accumulating substances for long periods of time. This allows a retrospective investigation of chronic drug abuse, monitoring continuous drug or pharmaceutical use, reveal in utero drug exposure or environmental exposures. We herein review the recent literature investigating drug incorporation mechanisms and drug detection in nails for forensic toxicological purposes. Mechanisms of drug incorporation have not yet been fully elucidated. However, some research has lately contributed to a better understanding of how substances are incorporated into nails, suggesting three potential mechanisms of drug incorporation: contamination from sweat, incorporation from nail bed and incorporation from germinal matrix. In addition, numerous methods dealing with the determination of drugs of abuse, medications and alcohol biomarkers in nails have been reported in studies over the years. The latter methods could find application in clinical and forensic toxicology. The studies herein reviewed point out how important it is to standardize and harmonize the methodologies (either pre-analytical or analytical) for nails analysis and the optimization of sampling as well as the development of proficiency testing programs and the determination of cut-off values. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. New Technique for Tibiotalar Arthrodesis Using a New Intramedullary Nail Device: A Cadaveric Study

    PubMed Central

    Eisenstein, Emmanuel D.; Rodriguez, Mario

    2016-01-01

    Introduction. Ankle arthrodesis is performed in a variety of methods. We propose a new technique for tibiotalar arthrodesis using a newly designed intramedullary nail. Methods. We proposed development of an intramedullary device for ankle arthrodesis which spared the subtalar joint using a sinus tarsi approach. Standard saw bones models and computer assisted modeling and stress analysis were used to develop different nail design geometries and determine the feasibility of insertion. After the final design was constructed, the device was tested on three cadaveric specimens. Results. Four basic nail geometries were developed. The optimal design was composed of two relatively straight segments, each with a different radius of curvature for their respective tibial and talar component. We successfully implemented this design into three cadaveric specimens. Conclusion. Our newly designed tibiotalar nail provides a new technique for isolated tibiotalar fusion. It utilizes the advantages of a tibiotalar calcaneal nail and spares the subtalar joint. This design serves as the foundation for future research to include compression options across the tibiotalar joint and eventual transition to clinical practice. PMID:27818800

  6. New Technique for Tibiotalar Arthrodesis Using a New Intramedullary Nail Device: A Cadaveric Study.

    PubMed

    Eisenstein, Emmanuel D; Rodriguez, Mario; Abdelgawad, Amr A

    2016-01-01

    Introduction . Ankle arthrodesis is performed in a variety of methods. We propose a new technique for tibiotalar arthrodesis using a newly designed intramedullary nail. Methods . We proposed development of an intramedullary device for ankle arthrodesis which spared the subtalar joint using a sinus tarsi approach. Standard saw bones models and computer assisted modeling and stress analysis were used to develop different nail design geometries and determine the feasibility of insertion. After the final design was constructed, the device was tested on three cadaveric specimens. Results . Four basic nail geometries were developed. The optimal design was composed of two relatively straight segments, each with a different radius of curvature for their respective tibial and talar component. We successfully implemented this design into three cadaveric specimens. Conclusion . Our newly designed tibiotalar nail provides a new technique for isolated tibiotalar fusion. It utilizes the advantages of a tibiotalar calcaneal nail and spares the subtalar joint. This design serves as the foundation for future research to include compression options across the tibiotalar joint and eventual transition to clinical practice.

  7. Scabies of the nail unit.

    PubMed

    Oh, Susan; Vandergriff, Travis

    2014-10-15

    Scabies limited to the nail unit is quite unusual, but may persist after treatment of crusted scabies. We present a man with a history of crusted scabies that resolved with treatment, but later the patient reported a chronic problem with crumbly, thickened nails, which were found to be harboring scabies mites.

  8. Aging changes in hair and nails

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/004005.htm Aging changes in hair and nails To use the sharing ... you age, your hair and nails begin to change. HAIR CHANGES AND THEIR EFFECTS Hair color change . ...

  9. Finite element validation of stress intensity factor calculation models for thru-thickness and thumb-nail cracks in double edge notch specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beres, W.; Koul, A.K.

    1994-09-01

    Stress intensity factors for thru-thickness and thumb-nail cracks in the double edge notch specimens, containing two different notch radius (R) to specimen width (W) ratios (R/W = 1/8 and 1/16), are calculated through finite element analysis. The finite element results are compared with predictions based on existing empirical models for SIF calculations. The effects of a change in R/W ratio on SIF of thru-thickness and thumb-nail cracks are also discussed. 34 refs.

  10. Plate refractive camera model and its applications

    NASA Astrophysics Data System (ADS)

    Huang, Longxiang; Zhao, Xu; Cai, Shen; Liu, Yuncai

    2017-03-01

    In real applications, a pinhole camera capturing objects through a planar parallel transparent plate is frequently employed. Due to the refractive effects of the plate, such an imaging system does not comply with the conventional pinhole camera model. Although the system is ubiquitous, it has not been thoroughly studied. This paper aims at presenting a simple virtual camera model, called a plate refractive camera model, which has a form similar to a pinhole camera model and can efficiently model refractions through a plate. The key idea is to employ a pixel-wise viewpoint concept to encode the refraction effects into a pixel-wise pinhole camera model. The proposed camera model realizes an efficient forward projection computation method and has some advantages in applications. First, the model can help to compute the caustic surface to represent the changes of the camera viewpoints. Second, the model has strengths in analyzing and rectifying the image caustic distortion caused by the plate refraction effects. Third, the model can be used to calibrate the camera's intrinsic parameters without removing the plate. Last but not least, the model contributes to putting forward the plate refractive triangulation methods in order to solve the plate refractive triangulation problem easily in multiviews. We verify our theory in both synthetic and real experiments.

  11. The influence of nail blocking conditions in cattle femoral fractures.

    PubMed

    Paolucci, Leopoldo A; Las Casas, Estevam B; Faleiros, Rafael R; Paz, Cahuê F R; Rocha Junior, Sergio S

    2018-05-07

    To investigate the effect of different fixation strategies of the intramedullary interlocking nail (IIN) on the mechanical behavior of a polymeric implant applied for femoral fracture fixation in calves, and to evaluate the performance of a glass fiber-reinforced polymer applied in a bovine femoral fracture reduction system, five Holstein male animals with a mean weight (±SD) of 62.8 ± 20.4 kg and aged 74 ± 15 were used to generate biomechanical parameters for this study. Twelve models of the fractured bovine femur, simulating a simple oblique fracture, were developed for use during the simulations. The models were divided into three groups, with each group of four models being associated with a different fixation strategy. Models were used to simulate the loading conditions corresponding to a calf in the transition (decubitus position to static position) condition. The maximum stresses found in each set (bone/implant) were compared with the reference stresses of each nail material. Maximum implant stresses were found in the screws and at the interface between the screw and the nail. The performance of implants was influenced by the material and fixation strategy, which can be confirmed by the stress values found in the set. The analysis indicated that the composite nail is able to withstand the loading demands in all fixation strategies. The finite element analysis (FEA) demonstrated that all polymeric materials analyzed provided sufficient resistance to withstand the loading forces imposed to the femur when an adequate blocking strategy was applied. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Nail Psoriasis: A Review of Treatment Options.

    PubMed

    Pasch, Marcel C

    2016-04-01

    Nail involvement affects 80-90 % of patients with plaque psoriasis, and is even more prevalent in patients with psoriatic arthritis. This review is the result of a systemic approach to the literature and covers topical, intralesional, conventional systemic, and biologic systemic treatments, as well as non-pharmacological treatment options for nail psoriasis. The available evidence suggests that all anti-tumor necrosis factor-α, anti-interleukin (IL)-17, and anti-IL-12/23 antibodies which are available for plaque psoriasis and psoriatic arthritis are highly effective treatments for nail psoriasis. Conventional systemic treatments, including methotrexate, cyclosporine, acitretin, and apremilast, as well as intralesional corticosteroids, can also be effective treatments for nail psoriasis. Topical treatments, including corticosteroids, calcipotriol, tacrolimus, and tazarotene, have also been shown to have a position in the treatment of nail psoriasis, particularly in mild cases. Finally, non-pharmacological treatment options, including phototherapy, photodynamic therapy, laser therapy, and several radiotherapeutic options, are also reviewed but cannot be advised as first-line treatment options. Another conclusion of this review is that the lack of a reliable core set of outcomes measures for trials in nail psoriasis hinders the interpretation of results, and is urgently needed.

  13. 78 FR 78382 - Steel Nails From China; Determination

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-26

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1114 (Review)] Steel Nails From China... U.S.C. 1675(c)), that revocation of the antidumping duty order on steel nails from China would be... 2013), entitled Steel Nails from China: Investigation No. 731-TA-1114 (Review). By order of the...

  14. Guidance on maintaining personal hygiene in nail care.

    PubMed

    Malkin, Bridget; Berridge, Pat

    Nail care is important in the maintenance of personal hygiene and is an essential aspect of patient care. Confusion about who should perform nail care for patients has resulted in poor practice and cycles of non-activity. This article provides guidance for nurses on performing routine nail care.

  15. Nail Hygiene

    MedlinePlus

    ... diligently cleaning and trimming fingernails, which may harbor dirt and germs and can contribute to the spread ... of their length, longer fingernails can harbor more dirt and bacteria than short nails, thus potentially contributing ...

  16. Treatment of Nail Psoriasis: Common Concepts and New Trends

    PubMed Central

    Oram, Yasemin; Akkaya, A. Deniz

    2013-01-01

    The lifetime incidence of nail involvement in psoriatic patients is estimated to be 80–90%, and the nails can be affected in 10% to 55% of psoriatic patients. Psoriasis may also solely involve the nails, without any other skin findings, in which the treatment can be more challenging. Nail psoriasis may lead to considerable impairment in quality of life due to aesthetic concerns and more importantly limitations in daily activities resulting from the associated pain, which may be overlooked by the physicians. Several topical and systemic treatment modalities, as well as radiation and light systems, have been used in the treatment of nail psoriasis. In the last decade, the introduction of biologic agents and the utilization of laser systems have brought a new insight into the treatment of nail psoriasis. This paper focuses on the recent advances, as well as the conventional methods, in treating nail psoriasis in adults and children, in reference to an extensive literature search. PMID:23762032

  17. Sarcoidosis: nail dystrophy without underlying bone changes.

    PubMed

    Wakelin, S H; James, M P

    1995-06-01

    Sarcoidosis is a chronic granulomatous disease of unknown origin that affects multiple organs and may present with a variety of skin lesions. Involvement of the nails is rare and almost invariably associated with underlying bone disease. We describe a patient with sarcoid nail dystrophy in whom this diagnosis was confirmed by a proximal nail fold biopsy. Radiologic investigation did not show evidence of an associated bone dystrophy in this case.

  18. Taxane-induced nail changes: Predictors and efficacy of the use of frozen gloves and socks in the prevention of nail toxicity.

    PubMed

    Can, Gulbeyaz; Aydiner, Adnan; Cavdar, Ikbal

    2012-07-01

    The primary endpoint of this study was to determine predictors of taxane-related nail toxicity. The secondary endpoint was to evaluate the efficacy of the use of frozen gloves and socks in the prevention of taxane-related nail toxicity. This descriptive, interventional, cross-sectional study was conducted with 200 patients. The patients were assigned to the frozen gloves/socks intervention group or control group. Frozen gloves/socks were applied only in hourly taxane-based treatments. The Patients Record Forms of the clinic were used in data collection. Nail changes were graded using the NCI Common Toxicity Criteria for each patient and treatment. Logistic regression analysis was performed to predict the factors that affect nail changes. The majority of the patients enrolled in the study were women diagnosed with breast cancer. The two groups were statistically similar for the cancer diagnosis, type and number of taxane cycles administered. Grade 1 nail toxicity was found in 34%, grade 2 in 11%, and grade 3 in 5.5% patients. Taxane-related nail toxicity was higher in patients who were female, had a history of diabetes, received capecitabine in conjunction with docetaxel and had breast or gynecological cancer diagnosis. Nail changes increased with an increase in the number of taxane cycles administered, BMI and severity of treatment-related neuropathy. The multivariate analysis demonstrated that BMI, breast or ovarian cancer diagnosis and the number of taxane cycles administered were the independent factors for this toxicity. No statistically significant difference in nail toxicity incidence and time to occurrence of nail changes was found between the intervention and the control groups. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Nail Scabies: An Unusual Presentation Often Overlooked and Mistreated.

    PubMed

    Tempark, Therdpong; Lekwuttikarn, Ramrada; Chatproedprai, Susheera; Wananukul, Siriwan

    2017-04-01

    Nail scabies is an interesting clinical presentation of scabies. Although it is usually found concomitant with characteristic dermatologic manifestations, it may present as an isolated finding in the immunocompromised host. This condition is commonly mistaken with other diseases such as nail dystrophy, nail psoriasis and onychomycosis. We report two cases of unusual nail presentations that provide clues to diagnosis. Also, literature on unusual nail and dermatologic presentations was reviewed to recognize dermatologist consideration for appropriate treatment options. © The Author [2016]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Close association between metal allergy and nail lichen planus: detection of causative metals in nail lesions.

    PubMed

    Nishizawa, A; Satoh, T; Yokozeki, H

    2013-02-01

    Lichen planus (LP) is a common skin disorder of unknown aetiology that affects the skin, mucous membranes and nails. Although metal allergies have been implicated in the development of oral LP (OLP), the contribution of these allergies to nail LP (NLP) has yet to be studied in detail. To elucidate the link between metal allergy and NLP. We retrospectively analysed 115 LP patients with respect to the contribution of metals to either NLP or OLP. We also attempted to detect the specific metals involved in these nail lesions. Of the 79 patients that received a metal patch test (PT), 24 (30%) were positive for at least one of the metal compounds tested. Notably, the prevalence of positive reactions to metals in the NLP patients was significantly higher as compared with the OLP patients (59% vs. 27%, P < 0.05). Among the 10 PT-positive patients with NLP, improvement of the skin lesions was seen in six of the patients after removal of dental materials containing causative metals or systemic disodium cromoglycate therapy. On the other hand, only 3 of 16 PT-positive patients with OLP exhibited improvement after the removal of dental materials. Causative metals in the dental fillings/braces were detected in the involved nail tissues. This study suggests that metal allergies are more closely associated with NLP vs. OLP, and that deposited metals in the nail apparatus contribute to the development of lichenoid tissue reactions in the nail bed and matrix. © 2012 The Authors. Journal of the European Academy of Dermatology and Venereology © 2012 European Academy of Dermatology and Venereology.

  1. Enhanced Ungual Permeation of Terbinafine HCl Delivered Through Liposome-Loaded Nail Lacquer Formulation Optimized by QbD Approach.

    PubMed

    Shah, Viral H; Jobanputra, Amee

    2018-01-01

    The present investigation focused on developing, optimizing, and evaluating a novel liposome-loaded nail lacquer formulation for increasing the transungual permeation flux of terbinafine HCl for efficient treatment of onychomycosis. A three-factor, three-level, Box-Behnken design was employed for optimizing process and formulation parameters of liposomal formulation. Liposomes were formulated by thin film hydration technique followed by sonication. Drug to lipid ratio, sonication amplitude, and sonication time were screened as independent variables while particle size, PDI, entrapment efficiency, and zeta potential were selected as quality attributes for liposomal formulation. Multiple regression analysis was employed to construct a second-order quadratic polynomial equation and contour plots. Design space (overlay plot) was generated to optimize a liposomal system, with software-suggested levels of independent variables that could be transformed to desired responses. The optimized liposome formulation was characterized and dispersed in nail lacquer which was further evaluated for different parameters. Results depicted that the optimized terbinafine HCl-loaded liposome formulation exhibited particle size of 182 nm, PDI of 0.175, zeta potential of -26.8 mV, and entrapment efficiency of 80%. Transungual permeability flux of terbinafine HCl through liposome-dispersed nail lacquer formulation was observed to be significantly higher in comparison to nail lacquer with a permeation enhancer. The developed formulation was also observed to be as efficient as pure drug dispersion in its antifungal activity. Thus, it was concluded that the developed formulation can serve as an efficient tool for enhancing the permeability of terbinafine HCl across human nail plate thereby improving its therapeutic efficiency.

  2. [Tibiotalocalcaneal arthrodesis using a retrograde nail locked in the sagittal plane].

    PubMed

    Veselý, R; Procházka, V; Visna, P; Valentová, J; Savolt, J

    2008-04-01

    To evaluate our experience with the use of a retrograde nail locked in the sagittal plane for tibiotalocalcaneal arthrodesis indicated in severe post-traumatic arthritis of the ankle. Twenty patients, 16 men and four women at an average age of 58.7 years (range, 23 to 72) were evaluated. All patients had severe post-traumatic changes in the talocrural and talocalcaneal joints. Five patients also had an equinus deformity. In two patients arthrodesis followed the treatment of purulent arthritis of the talocrural joint. A local fasciocutaneous flap was used for soft tissue reconstruction in three patients. All patients were operated on using the standard surgical technique. METHODS With the patient in a supine position, reamed by hand with the use of a driving rod, a straight retrograde AAN Orthofix nail was inserted through the heel bone and talus into the distal tibia and locked in these bones in the sagittal plane. No complications such as injury to the neurovascular plexus or pseudoarthrosis were recorded. Four patients showed a reaction to the proximal locking screw on the proximal tibial surface, which was treated by earlier screw removal under topical anaesthesia. Due to infectious complications, the nail had to be removed prematurely in one patient. The average Foot Function Index was 12 points (range, 10 to 15) and the average ankle-hindfoot score was 67.6 points (range, 59 to 84). Thirteen patients (65 %) were not limited in their daily activities or recreational sports, six (30 %) experienced pain in sports but not daily activities and one patient (5 %) reported pain even when walking. All fusions healed in the correct position within 18 weeks. Tibiotalocalcaneal arthrodesis is not a frequent surgical procedure in either trauma surgery or orthopaedics. For this complicated procedure, rather than intramedullary nails, internal fixation with screws or plates or external fixation are preferred. The high rate of bony healing can be explained by maintenance of

  3. Control of the micromovements of a composite-material nail design: A finite element analysis.

    PubMed

    Ben-Or, Mor; Shavit, Ronen; Ben-Tov, Tomer; Salai, Moshe; Steinberg, Ely L

    2016-02-01

    Intramedullary nail fixation is the most accepted modality for stabilizing long bone midshaft fractures. The commercially used nails are fabricated from Stainless Steel or Titanium. Composite-materials (CM) mainly carbon-fiber reinforced polymers (CFRP) have been gaining more interest and popularity due to their properties, such as modulus of elasticity close to that of bone, increased fatigue strength, and radio-opacity to irradiation that permits a better visualization of the healing process. The use of CFRP instead of metals allows better control of different directional movements along a fracture site. The purpose of this analysis was to design a CM intramedullary nail to enable micromovements as depicted on a finite element analysis method. We designed a three-dimentional femoral nail model. Three CFRP with different laminates arrangements, were included in the analysis. The finite element analysis involved applying vertical and horizontal loads on each of the designed and tested nails. The nails permitted a transverse micromovement of 0.75mm for the 45° lay-up and 1.5mm for the 90° lay-up for the CM, 1.38mm for the Titanium and 0.74mm for the Stainless Steel nails. The recorded axial movements were 0.53mm for the 45° lay-up, 0.87mm for the 90° lay-up, 0.46mm for the unsymmetrical lay-up CM, 0.046 for the Titanium and 0.02 for the Stainless Steel nails. Overall, the simulations showed that nail transverse micromovements can be reduced by using 45° carbon fiber orientations. Similar results were observed with each metal nails. We found that nail micromovements can be controlled by changing the directional stiffness using different lay-up orientations. These results can be useful for predicting nail micromovements under specified loading conditions which are crucial for stimulating callus formation in the early stages of healing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. A fatal nail gun injury--an unusual ricochet?

    PubMed

    Nadesan, K

    2000-01-01

    An 18-year-old construction worker suddenly collapsed while handling a power-actuated nail gun and died shortly after. A neat, almost circular puncture wound was found on the front of his left chest. No fire-arm residues were detected on the surrounding skin. The police stated that it was an accidental injury, at a construction site, where a nail fired from a nail gun by the deceased had deflected off the wall and struck him on the front of the chest. Since the entry wound appeared to be a neat hole, and that too on the front of the left chest overlying the heart area, there was reluctance on the part of the pathologist to accept it as an accidental injury due to a ricochet. A visit to the scene, interrogation of witnesses, examination of the alleged tool and post-mortem X-ray of the deceased were undertaken prior to autopsy. A bent nail was found in the heart. The scene visit and the subsequent autopsy revealed that the nail took a roughly circular flightpath after it had struck the wall, all the while travelling with its pointed end directed forward. Within the body too, the nail maintained the same path. Various medicolegal issues are discussed pertaining to nail-gun injuries. The importance of a visit to the scene, examination of the alleged tool, interrogation of witnesses and the X-ray of the body, all prior to autopsy, are emphasized. The conclusion was: accidental death due to the unusual ricochet of a nail.

  5. Soil nailing of a bridge fill embankment : construction report.

    DOT National Transportation Integrated Search

    1991-08-01

    Soil nailing as an alternative lateral earth support method has recently been introduced in Oregon to build the first permanent Soil-Nailed Wall on the State's Highway System. : The soil nailing technique was used for an underpass widening to provide...

  6. High-resolution ultrasonography in assessment of nail-related disorders.

    PubMed

    Singh, R; Bryson, D; Singh, H P; Jeyapalan, K; Dias, J J

    2012-09-01

    Disorders of the nail can pose a diagnostic challenge, and non-invasive imaging is frequently required to clarify diagnosis and delineate anatomy pre-operatively. We explored the use of high-resolution ultrasonography in the assessment of patients with nail disorders attending orthopaedic hand clinics. A search of a university teaching hospital musculoskeletal radiology database identified 36 patients (mean age 54.2 years) where ultrasonography was used to assess nail-related disorders between April 2003 and January 2007. Clinical, surgical and histological findings were correlated in these cases with ultrasound reports. Ultrasound findings correlated with the provisional diagnosis in 20 (61%) of 33 patients and provided a diagnosis in 3 patients where a provisional diagnosis was unavailable. In 7 of the 13 cases where the clinical diagnosis differed from ultrasound findings, a lump originally diagnosed as cystic in origin was shown to be solid on ultrasound. Different nail pathologies showed different characteristics on ultrasonography, including differences in vascularity, echogenicity, changes in nail structure/shape and extension into the nail bed, matrix, fold or evidence of bony erosion. The ultrasound findings correlated with histological analysis and intra-operative assessment in 10 of 15 patients who underwent operative treatment. Ultrasound provides important information on the anatomy of the nail apparatus and can differentiate solid and cystic lesions. It can be used as a diagnostic tool and can therefore help in pre-operative planning of nail-related disorders. In our series ultrasound supported or improved upon the clinical diagnosis in 31 (86%) out of the 36 patients presenting with nail-related disorders.

  7. [A favourable outcome in yellow nail syndrome: role of respiratory physiotherapy].

    PubMed

    Fournier, C; Just, N; Leroy, S; Wallaert, B

    2003-12-01

    The yellow nail syndrome is a rare condition that is easily diagnosed but the nail manifestations are poorly understood. A 51 year old patient presented with a chronic cough. The diagnosis was based on the typical appearance of the nails. The patient had bilateral basal bronchiectasis. Daily physiotherapy with bronchial drainage lead to a progressive improvement in the respiratory symptoms without recourse to antibiotics. Surprisingly the abnormalities of the nails disappeared after 2 years treatment. This observation illustrates the possibility of spontaneous resolution of severe nail abnormalities during the course of the yellow nail syndrome.

  8. Tibiotalocalcaneal arthrodesis using a dynamically locked retrograde intramedullary nail.

    PubMed

    Pelton, Kevin; Hofer, Jason K; Thordarson, David B

    2006-10-01

    Tibiotalocalcaneal arthrodesis is an important salvage method for patients with complex hindfoot problems, including Charcot arthropathy, osteonecrosis of the talus, combined arthritis of the ankle and subtalar joint, and failed total ankle arthroplasty. This study evaluated the results of a dynamic retrograde intramedullary nail for fixation with posterior to anterior distal interlocking screws placed through the calcaneus for tibiotalocalcaneal fusion. Thirty-three consecutive tibiotalocalcaneal fusions were done by a single surgeon (DBT) and were stabilized with a dynamic retrograde intramedullary nail. Time to fusion, impaction of the nail relative to the intramedullary canal, nail-tibial angle, and complications were noted. Average followup was 14 months. Twenty-nine of 33 feet (88%) fused at an average of 3.7 months after surgery. Average impaction of the nail was 2.3 (0.5 to 5.0) mm. Cortical hypertrophy at the tip of the rod or at the proximal interlocking screw was noted in 13 of 27 patients. A trend toward a higher nonunion rate was noted in patients with an increased nail-tibial angle. Dynamic retrograde intramedullary nailing for fixation of the tibiotalocalcaneal fusions is a good method of stabilizing this complex fusion construct.

  9. Removal of a broken trigen intertan intertrochanteric antegrade nail.

    PubMed

    Zheng, Xuan-Lin; Park, Young-Chang; Kim, Sungmin; An, Haemosu; Yang, Kyu-Hyun

    2017-02-01

    Implant breakage is a serious complication after cephalomedullary nailing for unstable intertrochanteric fracture. Failure usually occurs at the lag screw hole in the nail body. On the other hand, lag screw failure is extremely rare and occurs around the nail-lag screw junction. We experienced rare mechanical failure of the Intertan nail, which showed breakage at the lag screw hole and failure of the integrated compression screw underneath the main lag screw. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Opportunistic toenail onychomycosis. The fungal colonization of an available nail unit space by non-dermatophytes is produced by the trauma of the closed shoe by an asymmetric gait or other trauma. A plausible theory.

    PubMed

    Zaias, N; Escovar, S X; Rebell, G

    2014-08-01

    Opportunistic onychomycosis is defined, when a non-dermatophyte mould is cultured from an abnormal nail unit in the absence of a dermatophyte. The presumption is that the mould has caused the abnormal clinical appearance of the nail unit, yet there are no data available to substantiate this claim. Reports have only identified the mould being recovered from the nail unit niche. A review of the published dermatologic literature describing toenail opportunistic onychomycosis by non-dermatophyte fungi has shown toenails with onycholysis, nail bed (NB) keratosis and nail plate surface abnormalities. The appearance of these clinical changes is indistinguishable from the diagnosis of the Asymmetric Gait Nail Unit Signs (AGNUS). AGNUS is produced by the friction of the closed shoe in patients with an asymmetric gait, resulting primarily from the ubiquitous uneven flat feet. Most commonly, species of Acremonium (Cephalosporium), Aspergillus, Fusarium, Scopulariopsis and rarely species of many different fungi genera are capable of surviving and reproducing in a keratinous environment and change the clinical appearance of the involved nail unit. AGNUS toenails predispose to the colonization by the non-dermatophyte opportunistic fungi but not by dermatophyte fungi. © 2014 European Academy of Dermatology and Venereology.

  11. Current plate velocities relative to the hotspots incorporating the NUVEL-1 global plate motion model

    NASA Technical Reports Server (NTRS)

    Gripp, Alice E.; Gordon, Richard G.

    1990-01-01

    The NUVEL-1 model of current global relative plate velocities is presently incorporated into HS2-NUVEL1, a global model for plate velocities relative to hotspots; the results thus obtained are compared with those of the AM1-2 model of hotspot-relative plate velocities. While there are places in which plate velocities relative to the hotspots differ between HS2-NUVEL1 and AM1-2 by tens of degrees in direction and 15 mm/yr in speed, the hotspot Euler vectors differ with 95 percent confidence only for the Arabian and Indian plates. Plates attached to subducting slabs move faster relative to the hotspots than do plates without slabs.

  12. Finite element analysis of a pseudoelastic compression-generating intramedullary ankle arthrodesis nail.

    PubMed

    Anderson, Ryan T; Pacaccio, Douglas J; Yakacki, Christopher M; Carpenter, R Dana

    2016-09-01

    Tibio-talo-calcaneal (TTC) arthrodesis is an end-stage treatment for patients with severe degeneration of the ankle joint. This treatment consists of using an intramedullary nail (IM) to fuse the calcaneus, talus, and tibia bones together into one construct. Poor bone quality within the joint prior to surgery is common and thus the procedure has shown complications due to non-union. However, a new FDA-approved IM nail has been released that houses a nickel titanium (NiTi) rod that uses its inherent pseudoelastic material properties to apply active compression across the fusion site. Finite element analysis was performed to model the mechanical response of the NiTi within the device. A bone model was then developed based on a quantitative computed tomography (QCT) image for anatomical geometry and bone material properties. A total bone and device system was modeled to investigate the effect of bone quality change and gather load-sharing properties during gait loading. It was found that during the highest magnitude loading of gait, the load taken by the bone was more than 50% higher than the load taken by the nail. When comparing the load distribution during gait, results from this study would suggest that the device helps to prevent stress shielding by allowing a more even distribution of load between bone and nail. In conditions where bone quality may vary patient-to-patient, the model indicates that a 10% decrease in overall bone modulus (i.e. material stiffness) due to reduced bone mineral density would result in higher stresses in the nail (3.4%) and a marginal decrease in stress for the bone (0.5%). The finite element model presented in this study can be used as a quantitative tool to further understand the stress environment of both bone and device for a TTC fusion. Furthermore, the methodology presented gives insight on how to computationally program and use the unique material properties of NiTi in an active compression state useful for bone fracture healing

  13. Clinical Evidence for the Relationship between Nail Configuration and Mechanical Forces

    PubMed Central

    Ogawa, Rei

    2014-01-01

    Summary: Mechanobiology is an emerging field of science that focuses on the way physical forces and changes in cell or tissue mechanics contribute to development, physiology, and disease. As nails are always exposed to physical stimulation, mechanical forces may have a particularly pronounced effect on nail configuration and could be involved in the development of nail deformities. However, the role of mechanobiology in nail configuration and deformities has rarely been assessed. This review describes what is currently understood regarding the effect of mechanical force on nail configuration and deformities. On the basis of these observations, we hypothesize that nails have an automatic curvature function that allows them to adapt to the daily upward mechanical forces. Under normal conditions, the upward daily mechanical force and the automatic curvature force are well balanced. However, an imbalance between these 2 forces may cause nail deformation. For example, pincer nails may be caused by the absence of upward mechanical forces or a genetic propensity increase in the automatic curvature force, whereas koilonychias may occur when the upward mechanical force exceeds the automatic curvature force, thereby causing the nail to curve outward. This hypothesis is a new concept that could aid the development of innovative methods to prevent and treat nail deformities. PMID:25289309

  14. Anatomic aspects of tibiotalocalcaneal nail arthrodesis.

    PubMed

    Hyer, Christopher F; Cheney, Nick

    2013-01-01

    During the past 15 years, tibiotalocalcaneal nail arthrodesis has become an established procedure for the treatment of specific disorders of the hindfoot and ankle. However, controversy exists regarding the proper starting point for obtaining and maintaining the correct hindfoot position to allow successful fusion. One of the challenges with this procedure is aligning the tibial canal with the central talus and calcaneus for placement of the intramedullary nail. We performed a cadaver study to evaluate the radiographic and anatomic position of the tibial canal and the central talus as it relates to placement of a retrograde tibiotalocalcaneal nail. In our subjects, guide wires directed in an antegrade fashion down the tibial canal were more likely to enter lateral to the midline of the talus and miss the calcaneal body medially. These data have revealed a mismatch among the central axis of the tibia, talus, and calcaneus. Surgeons must pay careful attention to wire placement across these 3 bone segments during retrograde tibiotalocalcaneal nailing. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Quiz: Nails

    MedlinePlus

    ... you know about your nails? Find out by taking this quiz! About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice of Nondiscrimination Visit the Nemours Web site. Note: All information on KidsHealth® is for educational purposes ...

  16. Pseudoelastic intramedullary nailing for tibio-talo-calcaneal arthrodesis.

    PubMed

    Yakacki, Christopher M; Gall, Ken; Dirschl, Douglas R; Pacaccio, Douglas J

    2011-03-01

    Tibio-talo-calcaneal (TTC) arthrodesis is a procedure to treat severe ankle arthropathy by providing a pain-free and stable fusion. Intramedullary (IM) nails offer a method of internal fixation for TTC arthrodesis by providing compressive stability, as well as shear and torsional rigidity. IM nails have been developed to apply compression to the TTC complex during installation; however, current designs are highly susceptible to a loss of compression when exposed to small amounts of bone resorption and cyclic loading. Nickel titanium (NiTi) is a shape-memory alloy capable of recovering large amounts of deformation via shape-memory or pseudoelasticity. Currently, the next generation of IM nails is being developed to utilize the adaptive, pseudoelastic properties of NiTi and provide a fusion nail that is resistant to loss of compression or loosening. Specifically, the pseudoelastic IM nail contains an internal NiTi compression element that applies sustained compression during the course of fusion, analogous to external fixators. © 2011 Expert Reviews Ltd

  17. The Metacarpal Locked Intramedullary Nail: Comparative Biomechanical Evaluation of New Implant Design for Metacarpal Fractures.

    PubMed

    Boonyasirikool, Chinnakart; Tanakeatsakul, Sakkarin; Niempoog, Sunyarn

    2015-04-01

    The optimal fixation of metacarpal fracture should provide sufficient stability to permit early functionfor all types of fracture. However; it must preserve surrounding soft tissue during application and not require secondary removal due to its prominence. The prototype of metacarpal locked intramedullary nail (MCLN) was designed by our institute aiming to achieve those allfeatures. To biomechanically test our newly designed, locked metacarpal nail and compare with common current available fixation methods. Thirty chicken humeri were devided into 3 groups (n = 1 per group) according tofixation techniques: MCLN, 1.5 mm miniplate (Synthes), and Kirschner wire. After complete fixation, all specimens were osteotomized at mid-shaft creating transverse fractures. Five specimens from each group were tested by load of failure under axial compression, and another five under bending force. In axial compression model, the loads tofailure in MCLN group was greatest (460 ± 17 N), which was significant higher than the Kirschner wire group. The MCLN group also showed the highest load to failure in bending test (341 ± 10 N). This value reaches statistical significance when compared with plate and Kirschner wire groups. The MCLN construct provided higher stability than miniplate and Kirschner wire fixation both in axial and bending mode. Together with the minimally invasive and soft tissue-friendly design concept, this study suggests that MCLN is promising fixation option for metacarpal fracture.

  18. Eyelid Dermatitis Caused by Allergic Contact to Acrylates in Artificial Nails.

    PubMed

    Moreira, Jorge; Gonçalves, Rita; Coelho, Pedro; Maio, Tiago

    2017-03-13

    Over the past few years, there has been an increase in cases of allergic contact dermatitis caused by acrylates, because of the growing popularity of artificial nails. Pathological reactions to artificial nails typically occur on or around the nail area. Eyelid contact dermatitis due to artificial nails is rarely seen, especially in a nonoccupational setting. The authors report the case of a 45-year-old female accountant who developed eyelid dermatitis due to artificial nails.

  19. Eyelid Dermatitis Caused by Allergic Contact to Acrylates in Artificial Nails

    PubMed Central

    Moreira, Jorge; Gonçalves, Rita; Coelho, Pedro; Maio, Tiago

    2017-01-01

    Over the past few years, there has been an increase in cases of allergic contact dermatitis caused by acrylates, because of the growing popularity of artificial nails. Pathological reactions to artificial nails typically occur on or around the nail area. Eyelid contact dermatitis due to artificial nails is rarely seen, especially in a nonoccupational setting. The authors report the case of a 45-year-old female accountant who developed eyelid dermatitis due to artificial nails. PMID:28603598

  20. Impact of a Healthy Nails Program on Nail-Biting in Turkish Schoolchildren: A Controlled Pretest-Posttest Study

    ERIC Educational Resources Information Center

    Ergun, Ayse; Toprak, Rumeysa; Sisman, Fatma Nevin

    2013-01-01

    This study was conducted to examine the effect of a healthy nails program on nail-biting in Turkish schoolchildren. This quasi-experimental study was of pretest-posttest control group design. A total of 50 students of a primary school formed the intervention group, while 53 students from the same school formed the control group. Data were…

  1. Nonunion of the humerus following intramedullary nailing treated by Ilizarov hybrid fixation.

    PubMed

    Raschke, M; Khodadadyan, C; Maitino, P D; Hoffmann, R; Südkamp, N P

    1998-02-01

    A case of a posttraumatic humeral shaft nonunion, after intramedullary stabilization with a Seidel nail, is presented. Severe osteoporosis, an oligotrophic nonunion, subclinical infection, and adhesive capsulitis of the glenohumeral joint were present. Due to the subclinical infection and severe osteoporosis, other major invasive therapeutic options such as intramedullary nailing or compression plating and bone grafting were not applicable. Nonoperative treatment was also not indicated secondary to the pain and disability present. External fixation with the Ilizarov hybrid fixator seemed to offer a minimally invasive treatment modality without the need of additional bone grafting. After fourteen weeks of "callus massage," consisting of closed alternating compression and distraction with an Ilizarov hybrid fixator, osseous consolidation was achieved. Eight months after Ilizarov treatment the patient had returned to work as a mechanic. At the one-year follow-up examination, the patient presented pain free and with near normal shoulder and elbow motion, with stable osseous consolidation of the humerus. In some cases of nonunion of the humerus shaft, when standard treatment options are not recommended, external fixation with an Ilizarov hybrid fixator may offer a salvage procedure with a successful clinical outcome.

  2. Aeroheating model advancements featuring electroless metallic plating

    NASA Technical Reports Server (NTRS)

    Stalmach, C. J., Jr.; Goodrich, W. D.

    1976-01-01

    Discussed are advancements in wind tunnel model construction methods and hypersonic test data demonstrating the methods. The general objective was to develop model fabrication methods for improved heat transfer measuring capability at less model cost. A plated slab model approach was evaluated with cast models containing constantan wires that formed single-wire-to-plate surface thermocouple junctions with a seamless skin of electroless nickel alloy. The surface of a space shuttle orbiter model was selectively plated with scaled tiles to simulate, with high fidelity, the probable misalignments of the heatshield tiles on a flight vehicle. Initial, Mach 8 heating results indicated a minor effect of tile misalignment roughness on boundary layer transition, implying a possible relaxation of heatshield manufacturing tolerances. Some loss of the plated tiles was experienced when the model was tested at high heating rates.

  3. Retained portion of latex glove during femoral nailing. Case report.

    PubMed

    Sadat-Ali, M; Marwah, S; al-Habdan, I

    1996-11-01

    A case of retained glove during Kuntscher intramedullary nailing is described. An abscess around the glove could have lead to osteomyelitis. One need to be cautious feeling the top end of the nail while femoral nailing to avoid such a complication.

  4. An asymptotic Reissner-Mindlin plate model

    NASA Astrophysics Data System (ADS)

    Licht, Christian; Weller, Thibaut

    2018-06-01

    A mathematical study via variational convergence of a periodic distribution of classical linearly elastic thin plates softly abutted together shows that it is not necessary to use a different continuum model nor to make constitutive symmetry hypothesis as starting points to deduce the Reissner-Mindlin plate model.

  5. Nail Care Products

    MedlinePlus

    ... Acrylics") Artificial nails are composed primarily of acrylic polymers and are made by reacting together acrylic monomers, such as ethyl methacrylate monomer, with acrylic polymers, such as polymethylmethacrylate. When the reaction is completed, ...

  6. An updated digital model of plate boundaries

    NASA Astrophysics Data System (ADS)

    Bird, Peter

    2003-03-01

    A global set of present plate boundaries on the Earth is presented in digital form. Most come from sources in the literature. A few boundaries are newly interpreted from topography, volcanism, and/or seismicity, taking into account relative plate velocities from magnetic anomalies, moment tensor solutions, and/or geodesy. In addition to the 14 large plates whose motion was described by the NUVEL-1A poles (Africa, Antarctica, Arabia, Australia, Caribbean, Cocos, Eurasia, India, Juan de Fuca, Nazca, North America, Pacific, Philippine Sea, South America), model PB2002 includes 38 small plates (Okhotsk, Amur, Yangtze, Okinawa, Sunda, Burma, Molucca Sea, Banda Sea, Timor, Birds Head, Maoke, Caroline, Mariana, North Bismarck, Manus, South Bismarck, Solomon Sea, Woodlark, New Hebrides, Conway Reef, Balmoral Reef, Futuna, Niuafo'ou, Tonga, Kermadec, Rivera, Galapagos, Easter, Juan Fernandez, Panama, North Andes, Altiplano, Shetland, Scotia, Sandwich, Aegean Sea, Anatolia, Somalia), for a total of 52 plates. No attempt is made to divide the Alps-Persia-Tibet mountain belt, the Philippine Islands, the Peruvian Andes, the Sierras Pampeanas, or the California-Nevada zone of dextral transtension into plates; instead, they are designated as "orogens" in which this plate model is not expected to be accurate. The cumulative-number/area distribution for this model follows a power law for plates with areas between 0.002 and 1 steradian. Departure from this scaling at the small-plate end suggests that future work is very likely to define more very small plates within the orogens. The model is presented in four digital files: a set of plate boundary segments; a set of plate outlines; a set of outlines of the orogens; and a table of characteristics of each digitization step along plate boundaries, including estimated relative velocity vector and classification into one of 7 types (continental convergence zone, continental transform fault, continental rift, oceanic spreading ridge

  7. Biomechanical assessment of composite versus metallic intramedullary nailing system in femoral shaft fractures: A finite element study.

    PubMed

    Samiezadeh, Saeid; Tavakkoli Avval, Pouria; Fawaz, Zouheir; Bougherara, Habiba

    2014-08-01

    Intramedullary nails are the primary choice for treating long bone fractures. However, complications following nail surgery including non-union, delayed union, and fracture of the bone or the implant still exist. Reducing nail stiffness while still maintaining sufficient stability seems to be the ideal solution to overcome the abovementioned complications. In this study, a new hybrid concept for nails made of carbon fibers/flax/epoxy was developed in order to reduce stress shielding. The mechanical performance of this new implant in terms of fracture stability and load sharing was assessed using a comprehensive non-linear FE model. This model considers several mechanical factors in nine fracture configurations at immediately post-operative, and in the healed bone stages. Post-operative results showed that the hybrid composite nail increases the average normal force at the fracture site by 319.23N (P<0.05), and the mean stress in the vicinity of fracture by 2.11MPa (P<0.05) at 45% gait cycle, while only 0.33mm and 0.39mm (P<0.05) increases in the fracture opening and the fragments' shear movement were observed. The healed bone results revealed that implantation of the titanium nail caused 20.2% reduction in bone stiffness, while the composite nail lowered the stiffness by 11.8% as compared to an intact femur. Our results suggest that the composite nail can provide a preferred mechanical environment for healing, particularly in transverse shaft fractures. This may help bioengineers better understand the biomechanics of fracture healing, and aid in the design of effective implants. Copyright © 2014. Published by Elsevier Ltd.

  8. Nail polish poisoning

    MedlinePlus

    ... poisoning URL of this page: //medlineplus.gov/ency/article/002722.htm Nail polish poisoning To use the sharing features on this page, please enable JavaScript. This poisoning is from swallowing or breathing in ( ...

  9. Nail Bed Injuries

    MedlinePlus

    ... and Treatment Find a hand surgeon near you. Videos Figures Figure 1: The anatomy of the nail ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  10. Functional Analysis and Treatment of Nail Biting

    ERIC Educational Resources Information Center

    Dufrene, Brad A.; Watson, T. Steuart; Kazmerski, Jennifer S.

    2008-01-01

    This study applied functional analysis methodology to nail biting exhibited by a 24-year-old female graduate student. Results from the brief functional analysis indicated variability in nail biting across assessment conditions. Functional analysis data were then used to guide treatment development and implementation. Treatment included a…

  11. Nail Problems (Toenails)

    MedlinePlus

    ... the surface of the nail can be PODIAT PHYSIC filed off, followed by the application of an ... toes ◆ Repeated trauma to the feet from normal activities Problems If you suspect an infection due to ...

  12. Stress relaxation of grouted entirely large diameter B-GFRP soil nail

    NASA Astrophysics Data System (ADS)

    Li, Guo-wei; Ni, Chun; Pei, Hua-fu; Ge, Wan-ming; Ng, Charles Wang Wai

    2013-08-01

    One of the potential solutions to steel-corrosion-related problems is the usage of fiber reinforced polymer (FRP) as a replacement of steel bars. In the past few decades, researchers have conducted a large number of experimental and theoretical studies on the behavior of small size glass fiber reinforce polymer (GFRP) bars (diameter smaller than 20 mm). However, the behavior of large size GFRP bar is still not well understood. Particularly, few studies were conducted on the stress relaxation of grouted entirely large diameter GFRP soil nail. This paper investigates the effect of stress levels on the relaxation behavior of GFRP soil nail under sustained deformation ranging from 30% to 60% of its ultimate strain. In order to study the behavior of stress relaxation, two B-GFRP soil nail element specimens were developed and instrumented with fiber Bragg grating (FBG) strain sensors which were used to measure strains along the B-GFRP bars. The test results reveal that the behavior of stress relaxation of B-GFRP soil nail element subjected to pre-stress is significantly related to the elapsed time and the initial stress of relaxation procedure. The newly proposed model for evaluating stress relaxation ratio can substantially reflect the influences of the nature of B-GFRP bar and the property of grip body. The strain on the nail body can be redistributed automatically. Modulus reduction is not the single reason for the stress degradation.

  13. Partial Removal of Nail Matrix in the Treatment of Ingrown Nails: Prospective Randomized Control Study Between Curettage and Electrocauterization.

    PubMed

    Kim, Maru; Song, In-Guk; Kim, Hyung Jin

    2015-06-01

    The aim of this study was to compare the result of electrocauterization and curettage, which can be done with basic instruments. Patients with ingrown nail were randomized to 2 groups. In the first group, nail matrix was removed by curettage, and the second group, nail matrix was removed by electrocautery. A total of 61 patients were enrolled; 32 patients were operated by curettage, and 29 patients were operated by electrocautery. Wound infections, as early complication, were found in 15.6% (5/32) of the curettage group, 10.3% (3/29) of the electrocautery group patients each (P = .710). Nonrecurrence was observed in 93.8% (30/32) and 86.2% (25/29) of the curettage and electrocautery groups, respectively, (lower limit of 1-sided 90% confidence interval = -2.3% > -15% [noninferiority margin]). To remove nail matrix, the curettage is effective as well as the electrocauterization. Further study is required to determine the differences between the procedures. © The Author(s) 2014.

  14. Hand injury with a nail gun: a case report with literature review.

    PubMed

    Boya, Hakan; Uzun, Belkan

    2015-01-01

    The nail gun was introduced in the late 1950s to increase the ease of driving nails, studs, bolts, or staples into various hard surfaces. The nail gun is a potentially dangerous device that is still commonly used in the construction industry. Since its introduction, an increasing number of studies have reported injuries associated with nail guns. Nail gun-related injuries-such as to the head, neck, and chest-can be devastating, and in some cases, even fatal. Extremity injuries, notably in the hand, can cause loss of function, missed work, and long-term health effects. This case report describes a nail-gun injury of the hand along with a discussion of the unique features of and treatment strategies for nail gun injuries.

  15. The use of topical minoxidil to accelerate nail growth: a pilot study.

    PubMed

    Aiempanakit, Kumpol; Geater, Alan; Limtong, Preeyachat; Nicoletti, Kathleen

    2017-07-01

    Linear nail growth rate is affected by various conditions, one of which is the level of blood flow. Our supposition was that topical minoxidil, which has vasodilatory properties, can increase the rate of nail growth. The aim of this study was to determine the impact of topical minoxidil on nail growth. A 5% topical minoxidil solution was applied twice daily to the fingernails of 32 participants. Two groups of 16 participants were randomly chosen. In one group, the applications were made to the right index and left ring fingernails, and, in the other, the left index and right ring fingernails. During each visit (weekly during the first month and every 2 weeks during the second month), the nail length of six fingernails (index, middle, and ring of both hands) was measured using a digital caliper. Beginning in the first week, the mean nail length of the treated nails was greater than that of nails in the untreated group with statistical significance. There were no systemic or cutaneous side effects. During the first month, the mean growth of the treated nails was 4.27 mm/month compared with 3.91 mm/month in the untreated nails (P = 0.003). These findings suggest that a 5% concentration of topical minoxidil can stimulate nail growth with increased growth beginning in the first week of application. The results may have important implications for the treatment of nail disorders; however, a comparable study involving participants with nail disorders is highly recommended. © 2017 The International Society of Dermatology.

  16. Managing Chemotherapy Side Effects: Skin and Nail Changes

    MedlinePlus

    ... ational C ancer I nstitute Managing Chemotherapy Side Effects Skin and Nail Changes “I was glad to ... services national institutes of health Managing Chemotherapy Side Effects: Skin and Nail Changes Protect your skin from ...

  17. Mycobacteria in nail salon whirlpool footbaths, California.

    PubMed

    Vugia, Duc J; Jang, Yvonne; Zizek, Candi; Ely, Janet; Winthrop, Kevin L; Desmond, Edward

    2005-04-01

    In 2000, an outbreak of Mycobacterium fortuitum furunculosis affected customers using whirlpool footbaths at a nail salon. We swabbed 30 footbaths in 18 nail salons from 5 California counties and found mycobacteria in 29 (97%); M. fortuitum was the most common. Mycobacteria may pose an infectious risk for pedicure customers.

  18. Allergic contact dermatitis from acrylic nails in a flamenco guitarist.

    PubMed

    Alcántara-Nicolás, F A; Pastor-Nieto, M A; Sánchez-Herreros, C; Pérez-Mesonero, R; Melgar-Molero, V; Ballano, A; De-Eusebio, E

    2016-12-01

    Acrylates are molecules that are well known for their strong sensitizing properties. Historically, many beauticians and individuals using store-bought artificial nail products have developed allergic contact dermatitis from acrylates. More recently, the use of acrylic nails among flamenco guitarists to strengthen their nails has become very popular. A 40-year-old non-atopic male patient working as a flamenco guitarist developed dystrophy, onycholysis and paronychia involving the first four nails of his right hand. The lesions were confined to the fingers where acrylic materials were used in order to strengthen his nails to play the guitar. He noticed improvement whenever he stopped using these materials and intense itching and worsening when he began reusing them. Patch tests were performed and positive results obtained with 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxyethyl acrylate (2-HEA), ethyleneglycol-dimethacrylate (EGDMA) and 2-hydroxypropyl methacrylate (2-HPMA). The patient was diagnosed with occupational allergic contact dermatitis likely caused by acrylic nails. Artificial nails can contain many kinds of acrylic monomers but most cases of contact dermatitis are induced by 2-HEMA, 2-HPMA and EGDMA. This is the first reported case of occupational allergic contact dermatitis from acrylates in artificial nails in a professional flamenco guitar player. Since the practice of self-applying acrylic nail products is becoming very popular within flamenco musicians, we believe that dermatology and occupational medicine specialists should be made aware of the potentially increasing risk of sensitization from acrylates in this setting. © The Author 2016. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Nail involvement in patients with moderate-to-severe alopecia areata treated with oral tofacitinib.

    PubMed

    Lee, Ji Su; Huh, Chang-Hun; Kwon, Ohsang; Yoon, Hyun-Sun; Cho, Soyun; Park, Hyun-Sun

    2018-05-07

    A few anecdotal case reports demonstrated that tofacitinib improved nail changes associated with AA. To investigate nail changes in patients with AA treated with tofacitinib and evaluate the relationship between nail and hair responses to tofacitinib. This is a retrospective study of 33 adult patients with moderate-to-severe AA treated with oral tofacitinib monotherapy for at least 4 months. Fifteen patients had nail involvement and demonstrated more severe hair loss than those without nail involvement (p = .040). However, there was no significant difference in hair regrowth between two groups. Of 15 patients with nail involvement, 11 (73.3%) showed improvement regardless of type of nail change; the first improvement was observed at a median of 5 months (range, 1-11) after administration. Nail improvement was associated with neither initial severity of hair loss nor hair response to tofacitinib. Nail improvement tended to occur later than hair regrowth. Oral tofacitinib monotherapy improves nail involvement associated with AA. Nail involvement is not a poor prognosis factor in hair regrowth with tofacitinib treatment and there is no evident relationship between nail and hair responses.

  20. Mycobacteria in Nail Salon Whirlpool Footbaths, California

    PubMed Central

    Jang, Yvonne; Zizek, Candi; Ely, Janet; Winthrop, Kevin L.; Desmond, Edward

    2005-01-01

    In 2000, an outbreak of Mycobacterium fortuitum furunculosis affected customers using whirlpool footbaths at a nail salon. We swabbed 30 footbaths in 18 nail salons from 5 California counties and found mycobacteria in 29 (97%); M. fortuitum was the most common. Mycobacteria may pose an infectious risk for pedicure customers. PMID:15829204

  1. Fatigue failure of the cephalomedullary nail: revision options, outcomes and review of the literature.

    PubMed

    Tucker, Adam; Warnock, Michael; McDonald, Sinead; Cusick, Laurence; Foster, Andrew P

    2018-04-01

    Cephalomedullary nail (CMN) failure is a rare entity following hip fracture treatment. However, it poses significant challenges for revision surgery, both mechanically and biologically. Nail failure rates have been reported at < 2%; however, no published studies have reported revision surgery procedures and their respective outcomes. We present a regional experience, with outcomes, of the revision options. We identified 20 fatigued CMNs that underwent four different revision procedures. Mean age was 73 ± 15.24 years, with a 3:1 female preponderance, and a median ASA grade of 3. Post-operative CMN radiographs demonstrated a significant number of fractures were fixed in varus, with reductions in neck-shaft angles post-operatively. A "poor" quality of reduction resulted in significantly earlier nail failure, compared to "adequate" and "good" (p = 0.027). Tip-Apex Distance (TAD) mean was 23.2 ± 8.3 mm, and an adequate TAD with three-point fixation was seen in only 35% of cases. Mean time to failure was 401.0 ± 237.2 days, with mean age at failure of 74.0 ± 14.8 years. Options after failure included revision CMN nail, proximal femoral locking plate (PFLP), long-stem or restoration arthroplasty, or femoral endoprosthesis. Barthel Functional Index scores showed no significant difference at 3 and 12 months post-operatively, nor any difference between treatment groups. Mean 12-month mortality was 30%, akin to a primary hip fracture mortality risk according to NICE guidelines. Mortality rates were lowest in revision nails. Subsequent revision rates were higher in the PFLP group. There is no reported evidence on the best surgical technique for managing the failed CMN, with no clear functional benefit in the options above. Good surgical technique at the time of primary CMN surgery is critical in minimising fatigue failure. After revision, overall mortality rates were equivalent to reported primary hip fracture mortality rates. Further multicentre

  2. Knee arthodesis using a modular customized intramedullary nail.

    PubMed

    Letartre, R; Combes, A; Autissier, G; Bonnevialle, N; Gougeon, F

    2009-11-01

    Arthrodesis of the knee, particularly in infectious situations, can be achieved using either an external fixator or an intramedullary device. The objective of this study is to report the clinical, functional, and radiographic outcomes of a continuous series of 19 cases of knee arthrodesis using a customized modular intramedullary nailing system. The modular intramedullary nail offers a satisfactory functional result while maintaining limb length, in spite of a nonunion risk, since acting like a true endoprosthesis. In our retrospective series of 19 patients, the main source of patients were infected total knee replacements. The nail was customized from assembling a dual surface-sanded titanium component (femoral and tibial). The Lequesne Algofunctional score and the WOMAC score were recorded, as well as the length discrepancy between the lower extremities. Arthrodesis consolidation and the nail's fit in the shaft were verified on anterior-posterior (AP) and lateral radiographs. Five complications were observed: one anterior cortical break, one excessive tibial rotation, two cases of delayed union, and one nail revision due to residual nail instability. The postoperative Lequesne Algofunctional score was 13/24 and the WOMAC score 57/100. The nonunion rate was 32%. From a functional point of view, the patients who did not achieve complete union and those who did had similar scores. The subjective results were not as good in patients who did not achieve final consolidation. Modular intramedullary nailing simplifies the technique, shortens the procedure, and reduces the amount of blood loss at surgery. Our nonunion rate was high, although the functional result did not seem compromised by such nonunion. The risk of long-term implant failure was not studied and requires longer follow-up studies. Level IV therapeutic study. 2009 Published by Elsevier Masson SAS.

  3. When all you have is a dermatoscope— start looking at the nails

    PubMed Central

    Haenssle, Holger A.; Blum, Andreas; Hofmann-Wellenhof, Rainer; Kreusch, Juergen; Stolz, Wilhelm; Argenziano, Giuseppe; Zalaudek, Iris; Brehmer, Franziska

    2014-01-01

    Pigmented and non-pigmented nail alterations are a frequent challenge for dermatologists. A profound knowledge of clinical and dermatoscopic features of nail disorders is crucial because a range of differential diagnoses and even potentially life-threatening diseases are possible underlying causes. Nail matrix melanocytes of unaffected individuals are in a dormant state, and, therefore, fingernails and toenails physiologically are non-pigmented. The formation of continuous, longitudinal pigmented streaks (longitudinal melanonychia) may either be caused by a benign activation of matrix melanocytes (e.g., as a result of trauma, inflammation, or adverse drug reactions) or by a true melanocytic proliferation (e.g., in a nevus or melanoma). In general, non-continuous nail alterations, affecting only limited parts of the nail apparatus, are most frequently of non-melanocytic origin. Important and common differential diagnoses in these cases are subungual hemorrhage or onychomycosis. In addition, foreign bodies, bacterial infections, traumatic injuries, or artificial discolorations of the nail unit may less frequently cause non-continuous nail alterations. Many systemic diseases that may also show involvement of the nails (e.g., psoriasis, atopic dermatitis, lichen planus, alopecia areata) tend to induce alterations in numerous if not all nails of the hands and feet. A similar extensive and generalized alteration of nails has been reported after treatment with a number of systemic drugs, especially antibiotics and cytostatics. Benign or malignant neoplasms that may also affect the nail unit include glomus tumor, Bowen’s disease, squamous cell carcinoma, and rare collision tumors. This review aims to assist clinicians in correctly evaluating and diagnosing nail disorders with the help of dermatoscopy. PMID:25396079

  4. [Scabies of the nail unit in an infant].

    PubMed

    Finon, A; Desoubeaux, G; Nadal, M; Georgescou, G; Baran, R; Maruani, A

    2017-05-01

    There are no guidelines regarding the management of scabies in infants and recurrence is common at this age. We report the case of an infant with subungual hyperkeratosis and ungual lesions subsequent to classic scabies. A 7-month-girl, treated 6 weeks earlier with esdepallethrin for scabies, consulted for acquired lesions on 3 toe nails. These nails were thickened and displayed subungual hyperkeratosis. Physical examination of the skin, the finger nails and mucous membranes was otherwise normal. Fungal analyses were negative, but direct microscopic examination revealed numerous larvae of Sarcoptes scabiei as well as ovular debris. The child was treated with urea 40% to obtain chemical avulsion of the nails, and with topical esdepallethrin and a quarter tablet of ivermectin orally; there was no follow-up of the child. Ungual scabies has already been reported in crusted scabies and very rarely in classic scabies. Subungual and ungual locations of S. scabiei may constitute a source of reinfestation with scabies in infants. Treatment is not well defined and currently involves chemical avulsion of the nails and the application of topical antiscabies treatment. Copyright © 2016. Published by Elsevier Masson SAS.

  5. Modeling absolute plate and plume motions

    NASA Astrophysics Data System (ADS)

    Bodinier, G. P.; Wessel, P.; Conrad, C. P.

    2016-12-01

    Paleomagnetic evidence for plume drift has made modeling of absolute plate motions challenging, especially since direct observations of plume drift are lacking. Predictions of plume drift arising from mantle convection models and broadly satisfying observed paleolatitudes have so far provided the only framework for deriving absolute plate motions over moving hotspots. However, uncertainties in mantle rheology, temperature, and initial conditions make such models nonunique. Using simulated and real data, we will show that age progressions along Pacific hotspot trails provide strong constraints on plume motions for all major trails, and furthermore that it is possible to derive models for relative plume drift from these data alone. Relative plume drift depends on the inter-hotspot distances derived from age progressions but lacks a fixed reference point and orientation. By incorporating paleolatitude histories for the Hawaii and Louisville chains we add further constraints on allowable plume motions, yet one unknown parameter remains: a longitude shift that applies equally to all plumes. To obtain a solution we could restrict either the Hawaii or Louisville plume to have latitudinal motion only, thus satisfying paleolatitude constraints. Yet, restricting one plume to latitudinal motion while all others move freely is not realistic. Consequently, it is only possible to resolve the motion of hotspots relative to an overall and unknown longitudinal shift as a function of time. Our plate motions are therefore dependent on the same shift via an unknown rotation about the north pole. Yet, as plume drifts are consequences of mantle convection, our results place strong constraints on the pattern of convection. Other considerations, such as imposed limits on plate speed, plume speed, proximity to LLSVP edges, model smoothness, or relative plate motions via ridge-spotting may add further constraints that allow a unique model of Pacific absolute plate and plume motions to be

  6. Tibiotalocalcaneal Arthrodesis Using a Nitinol Intramedullary Hindfoot Nail.

    PubMed

    Hsu, Andrew R; Ellington, J Kent; Adams, Samuel B

    2015-10-01

    Tibiotalocalcaneal (TTC) arthrodesis using an intramedullary hindfoot nail is a common procedure for deformity correction and the treatment of combined tibiotalar and subtalar end-stage arthritis. Nonunion at one or both fusion sites is a difficult complication that can result in reoperation, significant morbidity, and below-knee amputation. There is currently a need for sustained compression across fusion sites using a TTC hindfoot nail with good mechanical stability. The DynaNail TTC Fusion System (MedShape, Inc, Atlanta, GA) uses an internal nitinol compression element to apply sustained compression across the tibiotalar and subtalar joints after surgery. In preliminary clinical cases, we have found that the nail is safe, reliable, and has promising clinical and radiographic results in settings of hindfoot arthritis, complex deformity, Charcot arthropathy, and talar avascular necrosis. Expert opinion, Level V. © 2015 The Author(s).

  7. Coexistence of nail lichen planus and lichen planus pigmentosus.

    PubMed

    Lemes, Luciana Rodino; Verde, Renata Brandão Villa; Durães, Sandra Maria Barbosa; Araripe, Adolpho de Alencar; Pantaleão, Luciana

    2016-01-01

    We describe a fifty-six-year old, Afro-descendent female patient showing dystrophy of her twenty nails and hyperchromic, asymptomatic macule on her face. Histopathological examination of the macule showed vacuolization of the basal layer, melanophages in the superficial dermis and lymphoplasmocytic inflammatory infiltrate. Nail biopsy revealed orthokeratotic hyperkeratosis and lichenoid inflammatory infiltrate. Lichen planus pigmentosus is an uncommon variety of lichen planus. It is characterized by typical hyperpigmented macules on the face and neck. Nail changes might be present in 10% of lichen planus cases, but no associations with lichen planus pigmentosus have been described. We report a case of lichen planus in twenty nails associated with lichen planus pigmentosus on the patient's face.

  8. MTR plates modeling with MAIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marelle, V.; Dubois, S.; Ripert, M.

    2008-07-15

    MAIA is a thermo-mechanical code dedicated to the modeling of MTR fuel plates. The main physical phenomena modeled in the code are the cladding oxidation, the interaction between fuel and Al-matrix, the swelling due to fission products and the Al/fuel particles interaction. The creeping of the plate can be modeled in the mechanical calculation. MAIA has been validated on U-Mo dispersion fuel experiments such as IRIS 1 and 2 and FUTURE. The results are in rather good agreement with post-irradiation examinations. MAIA can also be used to calculate in-pile behavior of U{sub 3}Si{sub 2} plates as in the SHARE experimentmore » irradiated in the SCK/Mol BR2 reactor. The main outputs given by MAIA throughout the irradiation are temperatures, cladding oxidation thickness, interaction thickness, volume fraction of meat constituents, swelling, displacements, strains and stresses. MAIA is originally a two-dimensional code but a three-dimensional version is currently under development. (author)« less

  9. [Current status of surgical technique for unreamed nailing of tibial shaft fractures with the UTN (unreamed tibia nail)].

    PubMed

    Krettek, C; Schandelmaier, P; Rudolf, J; Tscherne, H

    1994-11-01

    Nailing technique has changed in recent years in some important aspects which are not limited to the omitted reaming procedure. These changes concern patient positioning, reduction technique, the use of temporary stabilizers such as the 'Pinless', and determination of implant length and diameter. Approach and exposure techniques have been modified to new, less invasive procedures, in order to fulfill technical, functional and aesthetic requirements. Techniques and tricks have been developed for avoidance of fragment diastasis and axial and torsional malalignment. Finally, simple algorithms are described for the management of large bone defects, bilateral tibia shaft or ipsilateral femoral shaft fractures, number and location of locking bolts, the 'when and how' of patient mobilization and load bearing, and primary and secondary dynamization. These algorithms, techniques and procedures were developed in a series of 152 tibia shafts, which were stabilized with the AO unreamed tibia nail (UTN) in a prospective study between March 1989 and June 1994. Of these, 75 cases with a mean follow-up of 19.4 +/- 6.3 (range 11-37) months after trauma were reviewed. Fractures were classified according to Müller (1990): 14 type A, 37 type B and 24 type C. Closed soft tissue damage was categorized according to our classification: C0/1, n = 5; C2, n = 12; C3, n = 9 (Tscherne 1982). Among 49 open fractures 8 were OI, 18 OII, 10 OIIIA and 13 OIIIB (Gustilo 1976). The main minor intraoperative complication was drill bit breakage (n = 10), most frequently at the proximal locking holes. The main postoperative complication was breakage of locking bolts (n = 16), mainly between weeks 6 and 20. Minor secondary reinterventions were, in most cases, secondary dynamization under local anaesthesia. Major reintervention were: soft tissue reconstructions (n = 5), isolated cancellous bone graft (n = 6), and change of treatment (n = 12). There were nine changes to a reamed nail, two changes, in very

  10. Use of flexible facing for soil nail walls.

    DOT National Transportation Integrated Search

    2011-11-01

    Soil nail walls are a widely used technology for retaining vertical and nearly vertical cuts in soil. A : significant portion of the cost of soil nail wall construction is related to the construction of a reinforced : concrete face. The potential for...

  11. Green Nail Syndrome

    MedlinePlus

    ... if continued for one to four months. Alternatively, chlorine bleach, diluted 1:4 with water, is effective in suppressing growth of P. aeruginosa when applied topically to affected nails. Vinegar (acetic acid) has been reported to be useful in this ...

  12. Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures.

    PubMed

    Ma, Jian-Xiong; Wang, Jie; Xu, Wei-Guo; Yu, Jing-Tao; Yang, Yang; Ma, Xin-Long

    2015-01-01

    Reverse obliquity intertrochanteric fractures are a challenge for orthopedic surgeons. The optimal internal fixation for repairing this type of unstable intertrochanteric fractures remains controversial. This study aimed to compare the biomechanical properties in axial load and cyclical axial load of proximal femoral nail antirotation (PFNA) and proximal femoral locking compression plate (PFLCP) for fixation of reverse obliquity intertrochanteric fractures. Sixteen embalmed cadaver femurs were sawed to simulate reverse obliquity intertrochanteric fracture and instrumented with PFNA or PFLCP. Axial loads and axial cyclic loads were applied to the femoral head by an Instron tester. If the implant-femur constructs did not fail, axial failure load was added to the remaining implant-femur constructs. Mean axial stiffness for PFNA was 21.10% greater than that of PFLCP. Cyclic axial loading caused significantly less (p=0.022) mean irreversible deformation in PFNA (3.43 mm) than in PFLCP (4.34 mm). Significantly less (p=0.002) mean total deformation was detected in PFNA (6.16 mm) than in PFLCP (8.67 mm). For fixing reverse obliquity intertrochanteric fractures, PFNA is superior to PFLCP under axial load.

  13. Superfund Record of Decision (EPA Region 4): Independent Nail Company, Beaufort, South Carolina (first remedial action), September 1987. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1987-09-28

    The Independent Nail Company site, occupying 24.6 acres, is located near Beaufort, South Carolina. Land use in the vicinity of the site is a combination of fields, woodlands, and wetlands. Endangered and threatened species may occur within the area of influence of the site, although habitation has not been confirmed. The previous owners of the site, the Blake and Johnson Company, manufactured metallic screws and fasteners. In part of the manufacturing process, the company discharged approximately 33,000 gallons per day of plating wastewater into an unlined infiltration lagoon. The lagoon was in use from approximately 1969 to 1980. The Southmore » Carolina Department of Health and Environmental Control (SCDHEC) reported that the wastewater contained some organic cleaning solvents, phosphate, cyanide, chromium, cadmium, lead, mercury, nickel, zinc, copper and iron. In April 1980 the Blake and Johnson Company ceased operation. Two months later the Independent Nail Company purchased the plant. They currently operate a paneling nail coating process at the plant, but do not discharge any wastewater to the lagoon. The primary contaminants of concern to the soil and sediment include: cadmium, chromium, nickel and zinc.« less

  14. Withdrawal Strength and Bending Yield Strength of Stainless Steel Nails

    Treesearch

    Douglas R. Rammer; Samuel L. Zelinka

    2015-01-01

    It has been well established that stainless steel nails have superior corrosion performance compared to carbon steel or galvanized nails in treated wood; however, their mechanical fastening behavior is unknown. In this paper, the performance of stainless steel nails is examined with respect to two important properties used in wood connection design: withdrawal strength...

  15. Nonlinear modeling of truss-plate joints

    Treesearch

    Leslie H. Groom; Anton Polensek

    1992-01-01

    A theoretical model is developed for predicting mechanisms of load transfer between a wood member and a metal die-punched truss plate. The model, which treats a truss-plate tooth as a beam on an inelastic foundation of wood and applies Runae-Kutta numerical analysis to solve the governing differentia1 equations, predicts the load-disp1acement trace and ultimate load of...

  16. TOXIC TRACE METALS IN MAMMALIAN HAIR AND NAILS

    EPA Science Inventory

    Data have been compiled from the available world literature on the accumulation and bioconcentration of selected toxic trace metals in human hair and nails and other mammalian hair, fur, nails, claws, and hoofs. The toxic trace metals and metalloids include antimony, arsenic, bor...

  17. (Meth)Acrylate Occupational Contact Dermatitis in Nail Salon Workers: A Case Series.

    PubMed

    DeKoven, Samuel; DeKoven, Joel; Holness, D Linn

    Recently, many cases of acrylate-associated allergic contact dermatitis have appeared among nail salon workers. Common acrylate-containing products in nail salons include traditional nail polish, ultraviolet-cured shellac nail polish, ultraviolet-cured gel nails, and press-on acrylic nails. Nail salon technicians seen in the occupational medicine clinic in 2015 and 2016 were identified, and their patch test results and clinical features were summarized. Patch testing was done with the Chemotechnique (Meth)Acrylate nail series, and either the North American Standard series or the North American Contact Dermatitis Group screening series. Six patients were identified, all women, ages 38 to 58. Common presentations included erythematous dermatitis of the dorsa of the hands, palms, and forearms and fissures on the fingertips. Less common sites of eruptions included the periorbital region, cheeks, posterior ears, neck, sacral area, lateral thighs, and dorsa of the feet. All patients reacted to hydroxyethyl methacrylate, and 5 patients reacted to ethyl acrylate. Each patient also reacted to (meth)acrylates that are not found on either standard series, including ethyleneglycol dimethacrylate, 2-hydroxypropyl methacrylate, and 2-hydroxyethyl acrylate. The authors report 6 cases of allergic contact dermatitis to acrylates in nail technicians seen over the past year, representing a new trend in their clinic. These cases are reflective of a growing trend of nail technicians with allergic contact dermatitis associated with occupational (meth)acrylate exposure. Efforts to improve prevention are needed.

  18. Research on the reasonable pile spacing of micro pile composite soil nailing

    NASA Astrophysics Data System (ADS)

    Liu, Jun yan; Liu, Yan; Song, Xiang hua

    2017-08-01

    Through the numerical simulation software FLAC3D, study on the synergetic effect of micro pile composite soil nailing will be studied. By adjusting the micro pile spacing and analysing the displacement field and stress field of soil, we can find that supporting effect of the soil nail hasn’t work yet when the micro pile spacing is 2D. The soil arching between piles has been formed in the pile spacing 4D ∼ 6D. The composite effect of micro pile and soil nailing will be the best and the soil arch behind piles will be firstly formed in 6D, the horizontal saddle soil arch will be formed between the nails. The nail head coincidence pressure area and micro pile pressure area are overlapping to maintain stability in the soil between piles. When the micro pile spacing is 9D, the arch behind piles will be failure, the soil flows around, but the saddle arch between the nails into circular arch, the supporting effect of the soil nailing is enhanced. When the micro pile spacing is 12D, the arch of the nails becomes smaller, sliding surface appears primitively. Based on the conclusions above, it is suggested that the micro pile spacing between 2D ∼ 6D is suitable for the micro pile and soil nailing composite support. The conclusion can provide theoretical basis for the design and construction of micro pile composite soil nailing.

  19. Sensory factors affecting female consumers' acceptability of nail polish.

    PubMed

    Sun, C; Koppel, K; Adhikari, K

    2015-12-01

    The objectives of this study were to determine what sensory factors impact consumers' acceptability of nail polishes, to explore how these sensory factors impact consumers' acceptability of nail polishes, to investigate whether there are any consumer segments according to their overall acceptability on different nail polishes and to scrutinize how the consumer segments are related to the sensory factors. Ninety-eight females participated in a nail polish consumer study at Kansas State University. Eight commercial products belonging to four categories - regular (REG), gel (GEL), flake (FLK) and water-based (WAT) - were evaluated. Each nail polish sample was evaluated twice by each participant in two different tasks - a task devoted to applying and evaluating the product and a task devoted to observing the appearance and evaluating the product. Pearson's correlation analysis, analysis of variance (ANOVA), external preference mapping, cluster analysis and internal preference mapping were applied for data analysis. Participants' scores of overall liking of the nail polishes were similar in the application task and in the observation task. In general, participants liked the REG and GEL product samples more than the FLK and WAT samples. Among all the sensory attributes, appearance attributes were the major factors that affected participants' overall liking. Aroma seemed to be a minor factor to participants' overall liking. Some sensory attributes, such as runny, shininess, opacity, spreadability, smoothness, coverage and wet appearance, were found to drive participants' overall acceptability positively, whereas others such as pinhole, fatty-edges, blister, brushlines, pearl-like, flake-protrusion, glittery and initial-drag impacted participants' overall acceptability negatively. Four clusters of participants were identified according to their overall liking scores from both the application task and the observation task. Participants' acceptability, based on different

  20. Skin or nail culture

    MedlinePlus

    Mucosal culture; Culture - skin; Culture - mucosal; Nail culture; Culture - fingernail; Fingernail culture ... There, it is placed in a special dish (culture). It is then watched to see if bacteria, ...

  1. A Plate Tectonic Model for the Neoproterozoic with Evolving Plate Boundaries

    NASA Astrophysics Data System (ADS)

    Merdith, Andrew; Collins, Alan; Williams, Simon; Pisarevsky, Sergei; Müller, Dietmar

    2017-04-01

    The Neoproterozoic was dominated by the formation of the supercontinent Rodinia, its break-up and the subsequent amalgamation of Gondwana, during which, the planet experienced large climatic variations and the emergence of complex life. Here we present a topological plate model of the Neoproterozoic based on a synthesis of available geological and palaeomagnetic data. Subduction zones, which are well preserved in the geological record, are used as a proxy for convergent margins; evidence for mid-ocean ridges and transform motion is less clearly preserved, though passive margins are used as a proxy for spreading centres, and evidence for strike-slip motions are used to model transform boundaries. We find that the model presented here only predicts 70% of the total length of subduction active today, though it models similar lengths of both transform and divergent boundaries, suggesting that we have produced a conservative model and are probably underestimating the amount of subduction. Where evidence for convergent, divergent or transform motion is not preserved, we interpret the locations of plate boundaries based on the relative motions of cratonic crust as suggested through either palaeomagnetic data or the geological record. Using GPlates, we tie these boundaries together to generate a plate model that depicts the motion of tectonic plates through the Neoproterozoic. We omit India and South China from Rodinia completely, due to long-lived subduction preserved on margins of India and conflicting palaeomagnetic data for the Cryogenian, but tie them together due to similar Tonian aged accretionary patterns along their respective (present-day) north-western and northern margins, such that these two cratons act as a "lonely wanderer" for much of the Neoproterozoic, and form their own tectonic plate. We also introduce a Tonian-Cryogenian aged rotation of the Congo-São Francisco Craton relative to Rodinia to better fit palaeomagnetic data and account for thick passive

  2. Topical treatments for fungal infections of the skin and nails of the foot.

    PubMed

    Crawford, F; Hollis, S

    2007-07-18

    Fungal infections of the feet normally occur in the outermost layer of the skin (epidermis). The skin between the toes is a frequent site of infection which can cause pain and itchiness. Fungal infections of the nail (onychomycosis) can affect the entire nail plate. To assess the effects of topical treatments in successfully treating (rate of treatment failure) fungal infections of the skin of the feet and toenails and in preventing recurrence. We searched the Cochrane Skin Group Specialised Register (January 2005), the Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 1, 2005), MEDLINE and EMBASE (from inception to January 2005). We screened the Science Citation Index, BIOSIS, CAB - Health and Healthstar, CINAHL DARE, NHS Economic Evaluation Database and EconLit (March 2005). Bibliographies were searched. Randomised controlled trials (RCTs) using participants who had mycologically diagnosed fungal infections of the skin and nails of the foot. Two authors independently summarised the included trials and appraised their quality of reporting using a structured data extraction tool. Of the 144 identified papers, 67 trials met the inclusion criteria. Placebo-controlled trials yielded the following pooled risk ratios (RR) of treatment failure for skin infections: allylamines RR 0.33 (95% CI 0.24 to 0.44); azoles RR 0.30 (95% CI 0.20 to 0.45); ciclopiroxolamine RR 0.27 (95% CI 0.11 to 0.66); tolnaftate RR 0.19 (95% CI 0.08 to 0.44); butenafine RR 0.33 (95% CI 0.24 to 0.45); undecanoates RR 0.29 (95% CI 0.12 - 0.70). Meta-analysis of 11 trials comparing allylamines and azoles showed a risk ratio of treatment failure RR 0.63 (95% CI 0.42 to 0.94) in favour of allylamines. Evidence for the management of topical treatments for infections of the toenails is sparser. There is some evidence that ciclopiroxolamine and butenafine are both effective but they both need to be applied daily for prolonged periods (at least 1 year). The 6 trials of nail

  3. Comparative study of nail sampling techniques in onychomycosis.

    PubMed

    Shemer, Avner; Davidovici, Batya; Grunwald, Marcelo H; Trau, Henri; Amichai, Boaz

    2009-07-01

    Onychomycosis is a common problem. Obtaining accurate laboratory test results before treatment is important in clinical practice. The purpose of this study was to compare results of curettage and drilling techniques of nail sampling in the diagnosis of onychomycosis, and to establish the best technique and location of sampling. We evaluated 60 patients suffering from distal and lateral subungual onychomycosis and lateral subungual onychomycosis using curettage and vertical and horizontal drilling sampling techniques from three different sites of the infected nail. KOH examination and fungal culture were used for detection and identification of fungal infection. At each sample site, the horizontal drilling technique has a better culture sensitivity than curettage. Trichophyton rubrum was by far the most common pathogen detected by both techniques from all sampling sites. The drilling technique was found to be statistically better than curettage at each site of sampling, furthermore vertical drilling from the proximal part of the affected nail was found to be the best procedure for nail sampling. With each technique we found that the culture sensitivity improved as the location of the sample was more proximal. More types of pathogens were detected in samples taken by both methods from proximal parts of the affected nails.

  4. Application of soil nails to the stability of mine waste slopes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tant, C.R.; Drumm, E.C.; Mauldon, M.

    1996-12-31

    The traditional soil nailed structure incorporates grouted or driven nails, and a wire mesh reinforced shotcrete facing to increase the stability of a slope or wall. This paper describes the construction and monitoring of a full-scale demonstration of nailing to stabilize coal mine spoil. The purpose of the investigation is to evaluate the performance of nailed slopes in mine spoil using methods proven for the stabilization of soil walls and slopes. The site in eastern Tennessee is a 12 meter high slope of dumped fill, composed of weathered shale chips, sandstone, and coal. The slope was formed by {open_quotes}pre-regulatory{close_quotes} contourmore » surface mining operations and served as a work bench during mining. The material varies in size from silt to boulders, and has a small amount of cohesion. Portions of the mine spoil slope have experienced slope instability and erosion which have hampered subsequent reclamation activities. Three different nail spacings and three different nail lengths were used in the design. The 12 meter high structure is instrumented to permit measurement of nail strain, and vertical inclinometer readings and survey measurements will be used for the detection of ground movement. The results of this study will aid in the development of design recommendations and construction guidelines for the application of soil nailing to stabilize mine spoil.« less

  5. Inverse methods-based estimation of plate coupling in a plate motion model governed by mantle flow

    NASA Astrophysics Data System (ADS)

    Ratnaswamy, V.; Stadler, G.; Gurnis, M.

    2013-12-01

    Plate motion is primarily controlled by buoyancy (slab pull) which occurs at convergent plate margins where oceanic plates undergo deformation near the seismogenic zone. Yielding within subducting plates, lateral variations in viscosity, and the strength of seismic coupling between plate margins likely have an important control on plate motion. Here, we wish to infer the inter-plate coupling for different subduction zones, and develop a method for inferring it as a PDE-constrained optimization problem, where the cost functional is the misfit in plate velocities and is constrained by the nonlinear Stokes equation. The inverse models have well resolved slabs, plates, and plate margins in addition to a power law rheology with yielding in the upper mantle. Additionally, a Newton method is used to solve the nonlinear Stokes equation with viscosity bounds. We infer plate boundary strength using an inexact Gauss-Newton method with line search for backtracking. Each inverse model is applied to two simple 2-D scenarios (each with three subduction zones), one with back-arc spreading and one without. For each case we examine the sensitivity of the inversion to the amount of surface velocity used: 1) full surface velocity data and 2) surface velocity data simplified using a single scalar average (2-D equivalent to an Euler pole) for each plate. We can recover plate boundary strength in each case, even in the presence of highly nonlinear flow with extreme variations in viscosity. Additionally, we ascribe an uncertainty in each plate's velocity and perform an uncertainty quantification (UQ) through the Hessian of the misfit in plate velocities. We find that as plate boundaries become strongly coupled, the uncertainty in the inferred plate boundary strength decreases. For very weak, uncoupled subduction zones, the uncertainty of inferred plate margin strength increases since there is little sensitivity between plate margin strength and plate velocity. This result is significant

  6. Attic Retrofits Using Nail-Base Insulated Panels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mallay, David; Kochkin, Vladimir

    This project developed and demonstrated a roof/attic energy retrofit solution using nail-base insulated panels for existing homes where traditional attic insulation approaches are not effective or feasible. Nail-base insulated panels (retrofit panels) consist of rigid foam insulation laminated to one face of a wood structural panel. The prefabricated panels are installed above the existing roof deck during a reroofing effort.

  7. Knee arthrodesis with a long intramedullary nail as limb salvage for complex periprosthetic infections.

    PubMed

    Razii, Nima; Abbas, Ammar M I; Kakar, Rahul; Agarwal, Sanjeev; Morgan-Jones, Rhidian

    2016-12-01

    Periprosthetic infection following total knee arthroplasty is a devastating complication, which is not always satisfactorily resolved by revision surgery. Arthrodesis is a salvage alternative to above-knee amputation or permanent resection arthroplasty. Fixation options include internal compression plating, external fixation, and intramedullary nails. We retrospectively reviewed twelve consecutive cases (9 males, 3 females; mean age, 67 years) of knee arthrodesis with a long intramedullary nail, performed at a single institution between 2003 and 2014. Desired outcomes were the ability to mobilize without pain, solid radiographic fusion, and the eradication of infection. Mean follow-up was 48.5 months (range, 9-120 months). Eleven patients (92 %) demonstrated stable fusion, ten patients (83 %) were ambulatory without pain, and ten patients (83 %) remained without infection at most recent follow-up. Eight patients (67 %) achieved union at an average of 12 months; three required repeat procedures, achieving union at an average of 9 months. There was a significant difference (P < 0.01) between the numbers of previous operations amongst the eight patients who initially achieved union (mean, 3.25) and three who subsequently required repeat procedures (mean, 8.33). In contrast to similar studies, we performed a single-stage exchange where possible, while comparable ambulatory and fusion rates were observed. Numerous previous attempts at revision arthroplasty, co-morbidities, and infections with highly resistant organisms have been associated with further complications. Although technically challenging, knee arthrodesis with a long intramedullary nail offers an acceptable limb salvage procedure for carefully selected patients with complex periprosthetic infections.

  8. Biomechanical investigation of titanium elastic nail prebending for treating diaphyseal long bone fractures.

    PubMed

    Chen, Yen-Nien; Lee, Pei-Yuan; Chang, Chih-Wei; Ho, Yi-Hung; Peng, Yao-Te; Chang, Chih-Han; Li, Chun-Ting

    2017-03-01

    This study numerically investigated the deformation of titanium elastic nails prebent at various degrees during implantation into the intramedullary canal of fractured bones and the mechanism by which this prebending influenced the stability of the fractured bone. Three degrees of prebending the implanted portions of the nails were used: equal to, two times, and three times the diameter of the intramedullary canal. Furthermore, a simulated diaphyseal fracture with a 5-mm gap was created in the middle shaft portion of the bone fixed with two elastic nails in a double C-type configuration. End caps were simulated using a constraint equation. To confirm that the simulation process is able to present the mechanical response of the nail inside the intramedullary, an experiment was conducted by using sawbone for validation. The results indicated that increasing the degrees of nail prebending facilitated straightening the nails against the inner aspect of canal after implantation, with increase in stability under torsion. Furthermore, reducing nail prebending caused a larger portion of the nails to move closer to the loading site and center of bone after implantation; the use of end caps prevented the nail tips from collapsing and increased axial stability. End cap use was critical for preventing the nail tips from collapsing and for increasing the stability of the nails prebent at a degree equal to the diameter of the canal with insufficient frictional force between the nail and canal. Therefore, titanium elastic nail prebending in a double C-type configuration with a degree three times the diameter of the canal represents a superior solution for treating transverse fractures without a gap, whereas that with a degree equal to the diameter of the intramedullary canal and combined with end cap use represents an advanced solution for treating comminuted fractures in a diaphyseal long bone fracture.

  9. 77 FR 27080 - Certain Steel Nails From the United Arab Emirates

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-08

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1185 (Final)] Certain Steel Nails From... is materially injured by reason of imports from the United Arab Emirates of certain steel nails... of certain steel nails from the United Arab Emirates were being sold at LTFV within the meaning of...

  10. In vivo evaluation of a magnesium-based degradable intramedullary nailing system in a sheep model.

    PubMed

    Rössig, Christina; Angrisani, Nina; Helmecke, Patrick; Besdo, Silke; Seitz, Jan-Marten; Welke, Bastian; Fedchenko, Nickolay; Kock, Heiko; Reifenrath, Janin

    2015-10-01

    The biocompatibility and the degradation behavior of the LAE442 magnesium-based intramedullary interlocked nailing system (IM-NS) was assessed in vivo in a comparative study (stainless austenitic steel 1.4441LA) for the first time. IM-NS was implanted into the right tibia (24-week investigation period; nails/screws diameter: 9 mm/3.5 mm, length: 130 mm/15-40 mm) of 10 adult sheep (LAE442, stainless steel, n=5 each group). Clinical and radiographic examinations, in vivo computed tomography (CT), ex vivo micro-computed tomography (μCT), mechanical and histological examinations and element analyses of alloying elements in inner organs were performed. The mechanical examinations (four-point bending) revealed a significant decrease of LAE442 implant stiffness, force at 0.2% offset yield point and maximum force. Periosteal (new bone formation) and endosteal (bone decline) located bone alterations occurred in both groups (LAE442 alloy more pronounced). Moderate gas formation was observed within the LAE442 alloy group. The CT-measured implant volume decreased slightly (not significant). Histologically a predominantly direct bone-to-implant interface existed within the LAE442 alloy group. Formation of a fibrous tissue capsule around the nail occurred in the steel group. Minor inflammatory infiltration was observed in the LAE442 alloy group. Significantly increased quantities of rare earth elements were detected in the LAE442 alloy group. μCT examination showed the beginning of corrosion in dependence of the surrounding tissue. After 24 weeks the local biocompatibility of LAE442 can be considered as suitable for a degradable implant material. An application oriented interlocked intramedullary nailing system in a comparative study (degradable magnesium-based LAE442 alloy vs. steel alloy) was examined in a sheep model for the first time. We focused in particular on the examination of implant degradation by means of (μ-)CT, mechanical properties (four-point bending

  11. Nail gun injuries in residential carpentry: lessons from active injury surveillance.

    PubMed

    Lipscomb, H J; Dement, J M; Nolan, J; Patterson, D; Li, L

    2003-03-01

    To describe circumstances surrounding injuries involving nail guns among carpenters, calculate injury rates, identify high risk groups and preventive measures. and setting: Active injury surveillance was used to identify causes of injury among a large cohort of union residential and drywall carpenters. Injured carpenters were interviewed by experienced journeymen; enumeration of workers and hourworked were provided by the union. The combined data allowed definition of a cohort of carpenters, their hours worked, detailed information on the circumstances surrounding injuries, and identification of preventive measures from the perspectives of the injured worker and an experienced investigator. Nail guns were involved in 14% of injuries investigated. Ninety percent of these injuries were the result of the carpenter being struck, most commonly by a nail puncturing a hand or fingers. The injury rate among apprentices was 3.7 per 200 000 hours worked (95% confidence interval (CI) 2.7 to 4.9) compared with a rate of 1.2 among journeymen (95% CI 0.80 to 1.7). While not always the sole contributing factor, a sequential trigger would have likely prevented 65% of the injuries from tools with contact trip triggers. Training, engineering, and policy changes in the workplace and manufacturing arena are all appropriate targets for prevention of these injuries. Use of sequential triggers would likely decrease acute injury rates markedly. Over 70% of injuries among residential carpenters were associated with through nailing tasks (such as nailing studs or blocks, trusses or joists) or toe nailing (angled, corner nailing) as opposed to flat nailing used for sheathing activities; this provides some indication that contact trip tools could be used solely for flat nailing.

  12. Nail gun injuries in residential carpentry: lessons from active injury surveillance

    PubMed Central

    Lipscomb, H; Dement, J; Nolan, J; Patterson, D; Li, L

    2003-01-01

    Objective: To describe circumstances surrounding injuries involving nail guns among carpenters, calculate injury rates, identify high risk groups and preventive measures. Methods and setting: Active injury surveillance was used to identify causes of injury among a large cohort of union residential and drywall carpenters. Injured carpenters were interviewed by experienced journeymen; enumeration of workers and hourworked were provided by the union. The combined data allowed definition of a cohort of carpenters, their hours worked, detailed information on the circumstances surrounding injuries, and identification of preventive measures from the perspectives of the injured worker and an experienced investigator. Results: Nail guns were involved in 14% of injuries investigated. Ninety percent of these injuries were the result of the carpenter being struck, most commonly by a nail puncturing a hand or fingers. The injury rate among apprentices was 3.7 per 200 000 hours worked (95% confidence interval (CI) 2.7 to 4.9) compared with a rate of 1.2 among journeymen (95% CI 0.80 to 1.7). While not always the sole contributing factor, a sequential trigger would have likely prevented 65% of the injuries from tools with contact trip triggers. Conclusions: Training, engineering, and policy changes in the workplace and manufacturing arena are all appropriate targets for prevention of these injuries. Use of sequential triggers would likely decrease acute injury rates markedly. Over 70% of injuries among residential carpenters were associated with through nailing tasks (such as nailing studs or blocks, trusses or joists) or toe nailing (angled, corner nailing) as opposed to flat nailing used for sheathing activities; this provides some indication that contact trip tools could be used solely for flat nailing. PMID:12642553

  13. 76 FR 29266 - Certain Steel Nails From the United Arab Emirates

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-20

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1185 Preliminary] Certain Steel Nails... Emirates of certain steel nails, provided for in subheadings 7317.00.55, 7317.00.65 and 7317.00.75 of the... threatened with material injury by reason of LTFV imports of certain steel nails from the United Arab...

  14. Brown Nail-bed Arcs and Chronic Renal Disease

    PubMed Central

    Stewart, W. K.; Raffle, E. J.

    1972-01-01

    A brown arc affecting the distal part of the fingernail-bed, just proximal to the point of separation of the nail from its bed, has been found in 12 out of 34 patients with chronic renal disease (35%) compared with an incidence of less than 2% in a series of unselected patients. It represents a distinctive form of pigmentation, possibly due to lipochromes. No decisive association could be found between the presence or absence of the pigmented nail arc and the level of impaired renal function. Nevertheless it seems that renal disease predisposes towards the development of brown nail arcs. Imagesp786-a PMID:5014252

  15. Application of Soil Nailing Technique for Protection and Preservation Historical Buildings

    NASA Astrophysics Data System (ADS)

    Kulczykowski, Marek; Przewłócki, Jarosław; Konarzewska, Bogusława

    2017-10-01

    Soil nailing is one of the recent in situ techniques used for soil improvement and in stabilizing slopes. The process of soil nailing consists of reinforcing the natural ground with relatively small steel bars or metal rods, grouted in the pre-drilled holes. This method has a wide range of applications for stabilizing deep excavations and steep slopes. Soil nailing has recently become a very common method of slope stabilisation especially where situated beneath or adjacent to historical buildings. Stabilisation by nails drilled into existing masonry structures such as failing retaining walls abutments, provide long term stability without demolition and rebuilding costs. Two cases of soil nailing technology aimed at stabilising slopes beneath old buildings in Poland are presented in this paper. The first concerns application of this technology to repair a retaining wall supporting the base of the dam at the historic hydroelectric power plant in Rutki. The second regards a concept of improving the slope of the Castle Hill in Sandomierz. An analysis of the slope stability for the latter case, using stabilisation technique with the piling system and soil nailing was performed. Some advantages of soil nailing especially for protection of historical buildings, are also underlined. And, the main results of an economic comparison analysis are additionally presented.

  16. Nail haemorrhages in native highlanders of the Peruvian Andes

    PubMed Central

    Heath, Donald; Harris, Peter; Williams, David; Krüger, Hever

    1981-01-01

    Nail haemorrhages are of interest to the chest physician and cardiologist. While the common type in the distal part of the nail is produced by the minor trauma of daily life, the rarer form—scattered through the nail substance—appears to be related to hypoxaemia brought about by heart and lung disease. We thought it would be of interest to study a population which was naturally hypoxaemic because of living at high altitude. Accordingly we have studied the frequency and types of nail haemorrhage in Quechua Indians who are permanently exposed to the hypobaric hypoxia of the Andes. We found the haemorrhages to be common both in mestizos living on the coastal plain and in the native highlanders. They appeared to increase in frequency with altitude but were of the distal type and would thus seem to be the result of minor trauma as at sea level. However, just as in cases of cyanotic congenital heart disease at low altitude, those with exaggerated hypoxaemia and pronounced elevation of haematocrit—namely, subjects with Monge's disease (chronic mountain sickness)—had scattered haemorrhages in the nail substance. Images

  17. Linking plate reconstructions with deforming lithosphere to geodynamic models

    NASA Astrophysics Data System (ADS)

    Müller, R. D.; Gurnis, M.; Flament, N.; Seton, M.; Spasojevic, S.; Williams, S.; Zahirovic, S.

    2011-12-01

    While global computational models are rapidly advancing in terms of their capabilities, there is an increasing need for assimilating observations into these models and/or ground-truthing model outputs. The open-source and platform independent GPlates software fills this gap. It was originally conceived as a tool to interactively visualize and manipulate classical rigid plate reconstructions and represent them as time-dependent topological networks of editable plate boundaries. The user can export time-dependent plate velocity meshes that can be used either to define initial surface boundary conditions for geodynamic models or alternatively impose plate motions throughout a geodynamic model run. However, tectonic plates are not rigid, and neglecting plate deformation, especially that of the edges of overriding plates, can result in significant misplacing of plate boundaries through time. A new, substantially re-engineered version of GPlates is now being developed that allows an embedding of deforming plates into topological plate boundary networks. We use geophysical and geological data to define the limit between rigid and deforming areas, and the deformation history of non-rigid blocks. The velocity field predicted by these reconstructions can then be used as a time-dependent surface boundary condition in regional or global 3-D geodynamic models, or alternatively as an initial boundary condition for a particular plate configuration at a given time. For time-dependent models with imposed plate motions (e.g. using CitcomS) we incorporate the continental lithosphere by embedding compositionally distinct crust and continental lithosphere within the thermal lithosphere. We define three isostatic columns of different thickness and buoyancy based on the tectonothermal age of the continents: Archean, Proterozoic and Phanerozoic. In the fourth isostatic column, the oceans, the thickness of the thermal lithosphere is assimilated using a half-space cooling model. We also

  18. Effects of nail polish on microbial growth of fingernails. Dispelling sacred cows.

    PubMed

    Baumgardner, C A; Maragos, C S; Walz, J; Larson, E

    1993-07-01

    Nail polish worn on short, healthy nails does not appear to be associated with increased microbial counts on the fingernails. Additional studies to examine the effect of wearing nail polish on other aspects of hand hygiene may be warranted, however.

  19. A New Absolute Plate Motion Model for Africa

    NASA Astrophysics Data System (ADS)

    Maher, S. M.; Wessel, P.; Müller, D.; Harada, Y.

    2013-12-01

    The India-Eurasia collision, a change in relative plate motion between Australia and Antarctica, and the coeval ages of the Hawaiian Emperor Bend (HEB) and Louisville Bend of ~Chron 22-21 all provide convincing evidence of a global tectonic plate reorganization at ~50 Ma. Yet if it were a truly global event, then there should be a contemporaneous change in Africa absolute plate motion (APM) reflected by physical evidence somewhere on the Africa plate. This evidence might be visible in the Reunion-Mascarene bend, which exhibits many HEB-like features such as a large angular change close to ~50 Ma. Recently, the Reunion hotpot trail has been interpreted as a continental feature with incidental hotspot volcanism. Here we propose the alternative hypothesis that the northern portion of the chain between Saya de Malha and the Seychelles (Mascarene Plateau) formed as the Reunion hotspot was situated on the Carlsberg Ridge, contemporaneously forming the Chagos-Laccadive Ridge on the India plate. We have created a 4-stage model that explores how a simple APM model fitting the Mascarene Plateau can also satisfy the age progressions and geometry of other hotspot trails on the Africa plate. This type of model could explain the apparent bifurcation of the Tristan hotspot chain, the age reversals seen along the Walvis Ridge and the diffuse nature of the St. Helena chain. To test this hypothesis we have made a new African APM model that goes back to ~80 Ma using a modified version of the Hybrid Polygonal Finite Rotation Method. This method uses seamount chains and their associated hotspots as geometric constraints for the model, and seamount age dates to determine its motion through time. The positions of the hotspots can be moved to get the best fit for the model and to explore the possibility that the ~50 Ma bend in the Reunion-Mascarene chain reflects Africa plate motion. We will examine how well this model can predict the key features reflecting Africa plate motion and

  20. Global plate motion frames: Toward a unified model

    NASA Astrophysics Data System (ADS)

    Torsvik, Trond H.; Müller, R. Dietmar; van der Voo, Rob; Steinberger, Bernhard; Gaina, Carmen

    2008-09-01

    Plate tectonics constitutes our primary framework for understanding how the Earth works over geological timescales. High-resolution mapping of relative plate motions based on marine geophysical data has followed the discovery of geomagnetic reversals, mid-ocean ridges, transform faults, and seafloor spreading, cementing the plate tectonic paradigm. However, so-called "absolute plate motions," describing how the fragments of the outer shell of the Earth have moved relative to a reference system such as the Earth's mantle, are still poorly understood. Accurate absolute plate motion models are essential surface boundary conditions for mantle convection models as well as for understanding past ocean circulation and climate as continent-ocean distributions change with time. A fundamental problem with deciphering absolute plate motions is that the Earth's rotation axis and the averaged magnetic dipole axis are not necessarily fixed to the mantle reference system. Absolute plate motion models based on volcanic hot spot tracks are largely confined to the last 130 Ma and ideally would require knowledge about the motions within the convecting mantle. In contrast, models based on paleomagnetic data reflect plate motion relative to the magnetic dipole axis for most of Earth's history but cannot provide paleolongitudes because of the axial symmetry of the Earth's magnetic dipole field. We analyze four different reference frames (paleomagnetic, African fixed hot spot, African moving hot spot, and global moving hot spot), discuss their uncertainties, and develop a unifying approach for connecting a hot spot track system and a paleomagnetic absolute plate reference system into a "hybrid" model for the time period from the assembly of Pangea (˜320 Ma) to the present. For the last 100 Ma we use a moving hot spot reference frame that takes mantle convection into account, and we connect this to a pre-100 Ma global paleomagnetic frame adjusted 5° in longitude to smooth the reference

  1. The effect of retained intramedullary nails on tibial bone mineral density.

    PubMed

    Allen, J C; Lindsey, R W; Hipp, J A; Gugala, Z; Rianon, N; LeBlanc, A

    2008-07-01

    Intramedullary nailing has become a standard treatment for adult tibial shaft fractures. Retained intramedullary nails have been associated with stress shielding, although their long-term effect on decreasing tibial bone mineral density is currently unclear. The purpose of this study was to determine if retained tibial intramedullary nails decrease tibial mineral density in patients with successfully treated fractures. Patients treated with statically locked intramedullary nails for isolated, unilateral tibia shaft fractures were studied. Inclusion required that fracture had healed radiographically and that the patient returned to the pre-injury activity level. Data on patient demographic, fracture type, surgical technique, implant, and post-operative functional status were tabulated. Dual energy X-ray absorptiometry was used to measure bone mineral density in selected regions of the affected tibia and the contralateral intact tibia. Image reconstruction software was employed to ensure symmetry of the studied regions. Twenty patients (mean age 43; range 22-77 years) were studied at a mean of 29 months (range 5-60 months) following intramedullary nailing. There was statistically significant reduction of mean bone mineral density in tibiae with retained intramedullary nails (1.02 g/cm(2) versus 1.06 g/cm(2); P=0.04). A significantly greater decrease in bone mineral density was detected in the reamed versus non-reamed tibiae (-7% versus +6%, respectively; P<0.05). The present study demonstrates a small, but statistically significant overall bone mineral density decrease in healed tibiae with retained nails. Intramedullary reaming appears to be a factor potentiating the reduction of tibia bone mineral density in long-term nail retention.

  2. Hierarchic models for laminated plates

    NASA Technical Reports Server (NTRS)

    Szabo, Barna A.; Actis, Ricardo L.

    1991-01-01

    The research conducted in the formulation of hierarchic models for laminated plates is described. The work is an extension of the work done for laminated strips. The use of a single parameter, beta, is investigated that represents the degree to which the equilibrium equations of three dimensional elasticity are satisfied. The powers of beta identify members in the hierarchic sequence. Numerical examples that were analyzed with the proposed sequence of models are included. The results obtained for square plates with uniform loading and homogeneous boundary conditions are very encouraging. Several cross-ply and angle-ply laminates were evaluated and the results compared with those of the fully three dimensional model, computed using MSC/PROBE, and with previously reported work on laminated strips.

  3. Comparison of two intramedullary nails for tibiotalocalcaneal fusion: anatomic and radiographic considerations.

    PubMed

    Mückley, Thomas; Ullm, Sebastian; Petrovitch, Alexander; Klos, Kajetan; Beimel, Claudia; Fröber, Rosemarie; Hofmann, Gunther O

    2007-05-01

    Retrograde intramedullary nailing is an established procedure for tibiotalocalcaneal arthrodesis. This study was conducted to see whether, and if so to what extent, nail design modifications would influence the risk to anatomic structures and the bony coverage of the nail base. Six pairs of thawed fresh-frozen cadaver legs received two different intramedullary nails (N1: straight nail, lateral-medial tip locking; N2: valgus-curved nail, medial-lateral tip locking) under simulated operative conditions. The specimens were dissected; distances between the at-risk structures and the hardware were measured. The hindfoot axis and the volume of the intracalcaneal nail portion were determined with CT. At the plantar entry site, N2 was significantly farther from the flexor hallucis longus tendon (p=0.047), the medial plantar artery (p=0.026), and the lateral plantar nerve (p=0.026) than N1. The lateral-medial calcaneal locking screw of N1 damaged significantly more often the peroneus brevis tendon (p=0.03) than N2. The proximal tip-locking screw, N2, was significantly farther from the anterior tibial artery (p=0.075) and the deep (p=0.047) and superficial peroneal nerves (p=0.009) than N1; N1 was significantly farther from the great saphenous vein (p=0.075) than N2. The distal tip-locking screw, N1. damaged significantly more often the extensor digitorum longus (p=0.007), the anterior tibial artery(p = 0.04), and the deep and superficial peroneal nerves (p=0.03) than N2. CT did not show any significant changes in the hindfoot axis with either device; intracalcaneal nail volumes were similar. A curved nail can increase the distance to at-risk plantar structures. Medial-lateral nail-tip locking appears to have less risk to neurovascular structures. Safer retrograde intramedullary nailing for tibiotalocalcaneal fusion requires knowledge of the structures at risk and appropriate operative technique.

  4. Distal tibial fractures and non-unions treated with shortened intramedullary nail.

    PubMed

    Megas, P; Zouboulis, P; Papadopoulos, A X; Karageorgos, A; Lambiris, E

    2003-01-01

    We reviewed 18 patients, 14 with acute fractures and four with non-union of the distal tibia, treated between 1990 and 2001 with a shortened, reamed intramedullary nail. The mean follow-up was 38 (8-144) months. The fractures united at an average of 16 (12-18) weeks and the non-unions at 20 (12-30) weeks. Two patients required nail dynamization. No limb shortening nor material failures were seen. All patients returned to normal daily activities. Although technically demanding, intramedullary nailing for distal tibial fractures and non-unions with a shortened nail represents a safe and reliable method.

  5. Evaluating a county-based Healthy nail Salon Recognition Program

    EPA Science Inventory

    To determine whether nail solons that participate in the SF recognition program have reduced measured levels of toluene, methyl methacrylate (MMA), and total volatile organic compounds (TVOC)as compared to nail salons that do not participate. We also evaluated changes in worker ...

  6. Avoiding Pitfalls of Tibiotalocalcaneal Nail Malposition With Internal Rotation Axial Heel View.

    PubMed

    Callahan, Ryan; Juliano, Paul; Aydogan, Umur; Clayton, Justin

    2018-04-01

    Tibiotalocalcaneal (TTC) nails are often used for complex hind foot arthrodesis and deformity correction. The natural valgus alignment of the hindfoot creates a challenge to optimum placement of the guidewire and eventual nail with a straight or valgus-curved nail. Five fresh frozen cadavers were used for placement of a TTC guidewire with standard anterior-posterior (AP), lateral, and Harris axial heel views as a reference for proper placement. The limb was then rotated 15°, 30°, and 45° both internally and externally to evaluate the perceived amount of osseous purchase within the calcaneus. The TTC nail was then inserted and dissection was performed to demonstrate proximity of the nail to the sustentaculum tali and neurovascular structures. A 30° internal rotation Harris axial heel view demonstrated the most accurate representation of osseous purchase within the calcaneus with the guidewire and nail placement. When the guidewire was placed with standard imaging the nail was often ultimately placed in close proximity to the sustentaculum tali and neurovascular structures. Careful placement of the guidewire prior to reaming and nail placement should be undertaken to avoid neurovascular injury and to increase osseous purchase. For optimal guidewire placement, the authors suggest using appropriate anatomic landmarks and using a 30° internally rotated Harris axial heel view to verify correct placement. Level V: Expert opinion.

  7. The Hammer-and-Nail Phenomenon in Mathematics Education

    ERIC Educational Resources Information Center

    Lim, Kien H.

    2012-01-01

    This paper uses the hammer-and-nail metaphor to highlight the rigidity and impulsiveness that can be found in student mathematical behaviour. The hammer-and-nail phenomenon can be attributed to two plausible causes: (1) the way the human mind works; and (2) the way mathematics is traditionally taught in school. In this paper, the following aspects…

  8. Osteosynthesis with Rush's double nail by the "Eiffel Tower" method in pseudarthrosis impacted in good position and retarded union.

    PubMed

    Zinghi, G F; Lanfranchi, R

    1980-04-01

    The "Eiffel Tower" method of nailing has not attracted the interest in Italy that it deserves, both because its utilisaton in fractures is difficult when closed reduction of the fragments is difficult, and because the attention of surgeons has been progressively directed towards osteosynthesis by open reduction. Our experience over many years, however, has convinced us that, in the diaphysis, only the intramedullary nail can provide the quick recovery that is not always forthcoming in the case of plating. We need only think of comminuted fractures, where the possible necrosis of one or more fragments demands a certain amount of prudence in allowing direct weight bearing. Therefore, in adopting the double Rush system, we extended its application to the intramedullary osteosynthesis of metaphyseal fractures. It was a short step from this to the surgical treatment of pseudarthrosis impacted in good position or retarded union, the results of which were encouraging, as demonstrated by the eighty-one cases reported in this paper.

  9. Limb Lengthening Using the PRECICETM Nail System: Complications and Results

    PubMed Central

    Wiebking, Ulrich; Liodakis, Emmanouil; Kenawey, Mohamed; Krettek, Christian

    2016-01-01

    Background Three types of telescopic nails are mainly used for intramedullary limb lengthening nowadays. Despite some important advantages of this new technology (e.g. controlled distraction rate, not restricted availability, possibility to perform accordion maneuvers), few articles exist on clinical results and complications after lengthening with the PRECICETM nail (Ellipse, USA). Objectives The aim of the current study was to describe and analyze the complications associated with lengthening with the PRECICETM nail. Are the problems preventable when using the PRECICE, related to the distraction rate control, the lengthening goals and technique and handling? Methods We retrospectively reviewed the charts of 9 patients operated between 2012 and 2013 with a PRECICETM nail for a leg length discrepancy (LLD). The mean age of the patients was 32 years (range, 17 - 48 years). There were 5 femoral and 4 tibial procedures. The causes of LLD were posttraumatic (n = 5) and congenital (n = 4). The mean LLD was 36.4 ± 11.4 mm. The minimum follow-ups were 2 months (average, 5 months; range, 2 - 9 months). Results The mean distraction rate was 0.5 ± 0.1 mm/day. We observed in 7 patients differences in achieving the lengthening goals (average, 1.6 mm; range, -20.0 - 5.0 mm). Average lengthening was 34.7 ± 10.7 mm. All patients reached normal alignment and normal joint orientation. An unintentional loss of the achieved length during the consolidation phase was noticed in patients with delayed bone healing in two cases. In the first case (loss of 20mm distraction) the nail could be redistracted and the goal length was achieved. In the second case (loss of 10mm distraction) the nail broke shortly after the diagnosis and the nail was exchanged. Conclusions We report of loss of achieved length after lengthening with a telescopic nail. Weight bearing before complete consolidation of the regenerate might be a risk factor for that. Thorough examination of the limb length and careful

  10. Effects of ionic strength on passive and iontophoretic transport of cationic permeant across human nail.

    PubMed

    Smith, Kelly A; Hao, Jinsong; Li, S Kevin

    2009-06-01

    Transport across the human nail under hydration can be modeled as hindered transport across aqueous pore pathways. As such, nail permselectivity to charged species can be manipulated by changing the ionic strength of the system in transungual delivery to treat nail diseases. The present study investigated the effects of ionic strength upon transungual passive and iontophoretic transport. Transungual passive and anodal iontophoretic transport experiments of tetraethylammonium ion (TEA) were conducted under symmetric conditions in which the donor and receiver had the same ionic strength in vitro. Experiments under asymmetric conditions were performed to mimic the in vivo conditions. Prior to the transport studies, TEA uptake studies were performed to assess the partitioning of TEA into the nail. Permselectivity towards TEA was inversely related to ionic strength in both passive and iontophoretic transport. The permeability and transference number of TEA were higher at lower ionic strengths under the symmetric conditions due to increased partitioning of TEA into the nail. Transference numbers were smaller under the asymmetric conditions compared with their symmetric counterparts. The results demonstrate significant ionic strength effects upon the partitioning and transport of a cationic permeant in transungual transport, which may be instrumental in the development of transungual delivery systems.

  11. Treatment of psoriatic nails with indigo naturalis oil extract: a non-controlled pilot study.

    PubMed

    Lin, Yin-Ku; See, Lai-Chu; Chang, Ya-Ching; Huang, Yu-Huei; Chen, Jiun-Liang; Tsou, Teng-Cheng; Leu, Yann-Lii; Shen, Yu-Ming

    2011-01-01

    In the treatment of nail psoriasis, standardized therapeutic regimens are currently lacking. To evaluate the therapeutic efficacy of indigo naturalis oil extract in patients with nail psoriasis. Patients with nail psoriasis applied indigo naturalis oil extract on affected nails twice daily for 24 weeks. Efficacy was evaluated using the Nail Psoriasis Severity Index (NAPSI) and modified target NAPSI for the single most severely affected nail. Twenty-eight out of 32 patients completed the study. The mean NAPSI was 36.1 ± 14.7 at baseline and decreased to 14.9 ± 11.1 at week 24 while the mean modified target NAPSI was 11.7 ± 3.9 at baseline and decreased to 3.6 ± 3.2 at week 24. Indigo naturalis oil extract appeared to improve nail psoriasis. Although preliminary, these results indicate that it could provide a novel therapeutic option for nail psoriasis, a disease notoriously difficult to treat. Copyright © 2011 S. Karger AG, Basel.

  12. Withdrawal strength of ring-shank nails embedded in southern pine lumber

    Treesearch

    M. J. Skulteti; D. A. Bender; S. G. Winistorfer; D. G. Pollock

    1997-01-01

    Ring-shank nails are used extensively in post-frame construction due to their superior performance, yet surprisingly little testing has been done on nail sizes above 12d Experience in the post-frame industry suggests that published allowable design values for ring-shank nails may be overly conservative and need revision. The goal of the research reported herein was to...

  13. Nail gun injuries to the head with minimal neurological consequences: a case series.

    PubMed

    Makoshi, Ziyad; AlKherayf, Fahad; Da Silva, Vasco; Lesiuk, Howard

    2016-03-16

    An estimated 3700 individuals are seen annually in US emergency departments for nail gun-related injuries. Approximately 45 cases have been reported in the literature concerning nail gun injuries penetrating the cranium. These cases pose a challenge for the neurosurgeon because of the uniqueness of each case, the dynamics of high pressure nail gun injuries, and the surgical planning to remove the foreign body without further vascular injury or uncontrolled intracranial hemorrhage. Here we present four cases of penetrating nail gun injuries with variable presentations. Case 1 is of a 33-year-old white man who sustained 10 nail gunshot injuries to his head. Case 2 is of a 51-year-old white man who sustained bi-temporal nail gun injuries to his head. Cases 3 and 4 are of two white men aged 22 years and 49 years with a single nail gun injury to the head. In the context of these individual cases and a review of similar cases in the literature we present surgical approaches and considerations in the management of nail gun injuries to the cranium. Case 1 presented with cranial nerve deficits, Case 2 required intubation for low Glasgow Coma Scale, while Cases 3 and 4 were neurologically intact on presentation. Three patients underwent angiography for assessment of vascular injury and all patients underwent surgical removal of foreign objects using a vice-grip. No neurological deficits were found in these patients on follow-up. Nail gun injuries can present with variable clinical status; mortality and morbidity is low for surgically managed isolated nail gun-related injuries to the head. The current case series describes the surgical use of a vice-grip for a good grip of the nail head and controlled extraction, and these patients appear to have a good postoperative prognosis with minimal neurological deficits postoperatively and on follow-up.

  14. Modeling the hydrodynamics of Phloem sieve plates.

    PubMed

    Jensen, Kaare Hartvig; Mullendore, Daniel Leroy; Holbrook, Noel Michele; Bohr, Tomas; Knoblauch, Michael; Bruus, Henrik

    2012-01-01

    Sieve plates have an enormous impact on the efficiency of the phloem vascular system of plants, responsible for the distribution of photosynthetic products. These thin plates, which separate neighboring phloem cells, are perforated by a large number of tiny sieve pores and are believed to play a crucial role in protecting the phloem sap from intruding animals by blocking flow when the phloem cell is damaged. The resistance to the flow of viscous sap in the phloem vascular system is strongly affected by the presence of the sieve plates, but the hydrodynamics of the flow through them remains poorly understood. We propose a theoretical model for quantifying the effect of sieve plates on the phloem in the plant, thus unifying and improving previous work in the field. Numerical simulations of the flow in real and idealized phloem channels verify our model, and anatomical data from 19 plant species are investigated. We find that the sieve plate resistance is correlated to the cell lumen resistance, and that the sieve plate and the lumen contribute almost equally to the total hydraulic resistance of the phloem translocation pathway.

  15. Modeling the Hydrodynamics of Phloem Sieve Plates

    PubMed Central

    Jensen, Kaare Hartvig; Mullendore, Daniel Leroy; Holbrook, Noel Michele; Bohr, Tomas; Knoblauch, Michael; Bruus, Henrik

    2012-01-01

    Sieve plates have an enormous impact on the efficiency of the phloem vascular system of plants, responsible for the distribution of photosynthetic products. These thin plates, which separate neighboring phloem cells, are perforated by a large number of tiny sieve pores and are believed to play a crucial role in protecting the phloem sap from intruding animals by blocking flow when the phloem cell is damaged. The resistance to the flow of viscous sap in the phloem vascular system is strongly affected by the presence of the sieve plates, but the hydrodynamics of the flow through them remains poorly understood. We propose a theoretical model for quantifying the effect of sieve plates on the phloem in the plant, thus unifying and improving previous work in the field. Numerical simulations of the flow in real and idealized phloem channels verify our model, and anatomical data from 19 plant species are investigated. We find that the sieve plate resistance is correlated to the cell lumen resistance, and that the sieve plate and the lumen contribute almost equally to the total hydraulic resistance of the phloem translocation pathway. PMID:22811681

  16. Investigating relations among stress, sleep and nail cortisol and DHEA.

    PubMed

    Doan, Stacey N; DeYoung, Gerrit; Fuller-Rowell, Thomas E; Liu, Cindy; Meyer, Jerrold

    2018-03-01

    In the current study, we present data investigating the relationships among stress, sleep disturbance, self-control, and levels of cortisol (CORT) and dehydroepiandrosterone (DHEA) in fingernail clippings. Currently, hair CORT is the only routinely used noninvasive, validated, biomarker of chronic exposure to stress-related hormones. Nail clippings represent an important potential alternative sample matrix for assessing chronic hormone exposure, as it offers a different timeline of hormone incorporation than scalp hair, and may be obtainable from populations in which hair either is lacking or is unavailable for cultural reasons. Moreover, there is established precedent for using fingernail clippings to attain biomarker data. However, the value of nail hormone assessment for psychological research is currently unknown due to a paucity of information on the relations between nail hormone concentrations and environmental or psychological variables. In the present study, we collected data from a low income, minority population (N = 47; 97% African American) to demonstrate feasibility and acceptability of nail collection and analysis of the adrenal steroids CORT and DHEA. Participants reported on perceived stress, sleep and self-control abilities. Correlational analyses suggest that exposure to stressful events, disturbances in sleep and waking were associated with higher levels of nail DHEA, while self-control was associated with higher levels of nail CORT. We discuss the potential importance of this methodology for investigating biological, behavioral, and subjective indices of stress and well-being.

  17. Neurovascular Structures at Risk With Curved Retrograde TTC Fusion Nails.

    PubMed

    de Cesar Netto, Cesar; Johannesmeyer, David; Cone, Brent; Araoye, Ibukunoluwa; Hudson, Parke William; Sahranavard, Bahman; Johnson, Michael; Shah, Ashish

    2017-10-01

    The purpose of this study was to assess the risk of iatrogenic injury to plantar neurovascular structures of the foot during insertion of a curved retrograde tibiotalocalcaneal (TTC) fusion nail. Ten below-knee thawed fresh-frozen cadaveric specimens underwent curved retrograde nailing of the ankle. The shortest distance between the nail and the main plantar neurovascular branches and injured structures were recorded during dissection. We also evaluated the relative position of these structures along 2 lines (AB, connecting the calcaneus to the first metatarsal, and BC, connecting the first and fifth metatarsal). The lateral plantar artery was found to be in direct contact with the nail 70% of the time, with a macroscopic laceration 30% of the time. The Baxter nerve was injured 20% of the time, as was the lateral plantar nerve. The medial plantar artery and nerve were never injured. The most proximal structure to cross line AB was the Baxter nerve followed by the lateral plantar artery, the nail, the lateral plantar nerve, and the medial plantar nerve. Our cadaveric anatomic study found that the most common structures at risk for iatrogenic injury by lateral curved retrograde TTC fusion nails were the lateral plantar artery and nerve, and the Baxter nerve. Determination of a true neurovascular safe zone is challenging and therefore warrants careful operative dissection to minimize neurovascular injuries.

  18. Numerical modelling of instantaneous plate tectonics

    NASA Technical Reports Server (NTRS)

    Minster, J. B.; Haines, E.; Jordan, T. H.; Molnar, P.

    1974-01-01

    Assuming lithospheric plates to be rigid, 68 spreading rates, 62 fracture zones trends, and 106 earthquake slip vectors are systematically inverted to obtain a self-consistent model of instantaneous relative motions for eleven major plates. The inverse problem is linearized and solved iteratively by a maximum-likelihood procedure. Because the uncertainties in the data are small, Gaussian statistics are shown to be adequate. The use of a linear theory permits (1) the calculation of the uncertainties in the various angular velocity vectors caused by uncertainties in the data, and (2) quantitative examination of the distribution of information within the data set. The existence of a self-consistent model satisfying all the data is strong justification of the rigid plate assumption. Slow movement between North and South America is shown to be resolvable.

  19. Treatment of Displaced Intra-articular Calcaneal Fractures by Intramedullary Nail. Preliminary Report.

    PubMed

    Falis, Mirosław; Pyszel, Krystian

    2016-03-23

    Open reduction and plate stabilisation is a recognised method of treatment of intra-articular calcaneal fractures. The surgical approach to the calcaneal bone used in these procedures is associated with a high risk of complications. The aim of this paper is to present the author's experience with a new surgical method and analyse early outcomes of the treatment of calcaneal fractures by Calcanail intramedullary nailing. The study encompassed 17 patients (5 women and 12 men) with 18 calcaneal fractures (5 in the right foot and 13 in the left foot). The mean age of the patients was 47 years (range: 22-68 years). The mean time between the injury and surgery was 6 days (range: 3-14 days). The mean duration of follow-up was 12 months (range: 6-18 months). The fractures were classified according to the system presented by Guy Utheza. Bone union was achieved in all patients within 12 weeks of surgery. No infectious complications were observed. The mean AOFAS score was 82/100. Mean Bohler's angle was -3 degrees pre-operatively and +29 degrees post-operatively. 1. The use of Calcanail intramedullary nailing in the treatment of displaced intra-articular fractures is a minimally invasive procedure associated with a low risk of complications. 2. The innovative posterior approach allows for the intrafocal reduction of an articular surface fracture through the prepared intramedullary canal.

  20. CalNail : a design tool for soil nail projects using field case histories.

    DOT National Transportation Integrated Search

    2006-06-01

    Currently, geotechnical staff within Caltrans do not have ready access to detailed information on : previously designed soil nail walls. Much of this information is kept by individual designers, or stored in : paper format, with no organized method o...

  1. Complications of tibio-talar-calcaneal fusion using intramedullary nails.

    PubMed

    Fenton, P; Bali, N; Matheshwari, R; Youssef, B; Meda, K

    2014-12-01

    Hindfoot nails are being increasingly used, however significant complications can occur. The purpose of this study was to assess the complications following the use of hindfoot nails at our institution. We identified patients from a retrospective database. All underwent hindfoot nailing under the care of the senior author. Details of complications were recorded. We identified 52 patients undergoing 55 procedures. Mean follow up was 44.8 months (18-69). Forty patients achieved ankle fusion and 36 subtalar joint fusion. Complications included prominent metalwork in 13 patients, CRPS in five and one peri-prosthetic fracture. Nine developed deep infection, and of these limb salvage was achieved in six patients by removal of metalwork, debridement and insertion of antibiotic loaded cement beads. The remaining three patients underwent below knee amputation. Significant complications can occur, although limb preservation was possible in most cases of deep infection. Hindfoot nailing should be reserved as salvage procedure. Copyright © 2014 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  2. Arthrodesis in septic knees using a long intramedullary nail: 17 consecutive cases.

    PubMed

    Leroux, B; Aparicio, G; Fontanin, N; Ohl, X; Madi, K; Dehoux, E; Diallo, S

    2013-06-01

    Intramedullary nailing using long or modular nails is the most reliable mean of achieving femorotibial fusion. Here, we report the operative, clinical, functional, and radiological outcomes of 17 long intramedullary nail arthodeses in patients with infection. Clinical and functional outcomes after long intramedullary nailing are at least as good as those obtained using other implants. We retrospectively reevaluated 17 patients after unilateral two-stage knee arthrodesis with a long titanium intramedullary nail and autologous bone grafting. We evaluated satisfaction, leg length discrepancy, and function (Lequesne and WOMAC indices). Radiographs were obtained to assess fusion, time to fusion, and femorotibial angles. No cases of material failure were recorded. One or more complications occurred in seven patients. Mean limb shortening was 27.6mm. Of the 17 patients, 15 were satisfied with the procedure. The mean Lequesne index was 10.5/24 and the mean overall WOMAC score was 26/88. Fusion was achieved in 16 patients, with a mean time to fusion of 5 months. Mean femorotibial angles were 178.6° of varus and 1.9° of flexion. This simple and rapid surgical technique provides functional outcomes similar to those obtained using modular nails. The fusion rate is high. Nail extraction is simple and causes minimal damage, in contrast to modular nails. Increased attention to misalignment is needed. Level IV, retrospective study. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  3. Asymptotic derivation of nonlocal plate models from three-dimensional stress gradient elasticity

    NASA Astrophysics Data System (ADS)

    Hache, F.; Challamel, N.; Elishakoff, I.

    2018-01-01

    This paper deals with the asymptotic derivation of thin and thick nonlocal plate models at different orders from three-dimensional stress gradient elasticity, through the power series expansions of the displacements in the thickness ratio of the plate. Three nonlocal asymptotic approaches are considered: a partial nonlocality following the thickness of the plate, a partial nonlocality following the two directions of the plates and a full nonlocality (following all the directions). The three asymptotic approaches lead at the zeroth order to a nonlocal Kirchhoff-Love plate model, but differ in the expression of the length scale. The nonlocal asymptotic models coincide at this order with the stress gradient Kirchhoff-Love plate model, only when the nonlocality is following the two directions of the plate and expressed through a nabla operator. This asymptotic model also yields the nonlocal truncated Uflyand-Mindlin plate model at the second order. However, the two other asymptotic models lead to equations that differ from the current existing nonlocal engineering models (stress gradient engineering plate models). The natural frequencies for an all-edges simply supported plate are obtained for each model. It shows that the models provide similar results for low orders of frequencies or small thickness ratio or nonlocal lengths. Moreover, only the asymptotic model with a partial nonlocality following the two directions of the plates is consistent with a stress gradient plate model, whatever the geometry of the plate.

  4. Jumbo Cutter for Removal of A Bent Femoral Interlocking Nail: A Cost Effective Method

    PubMed Central

    Dhanda, Manjeet Singh; Sharma, Sansar C; Ali, Nadeem; Bhat, Abedullah

    2015-01-01

    Closed diaphyseal femoral shaft fractures can be treated with multiple surgical options. It is more challenging to remove a bent nail than a broken one because it is difficult to retrieve the bent nail through the intramedullary canal. Various authors have published their techniques for removal of bent femoral interlocking nail. This article describes a simple technique using Jumbo cutter for sectioning and removal of bent interlocking nail. This technique will help orthopaedic surgeons to remove bent nail without using any specialised metal cutting instruments. PMID:26266173

  5. A rheological model for immersed corrugated elastic plates.

    PubMed

    Meier, D; Franklin, H; Predoi, M V; Rousseau, M; Izbicki, J L

    2017-03-01

    The influence of surface imperfections on the propagation of guided waves in an immersed elastic plate can be interpreted by means of a rheological model. The corrugated surface is modeled by a very thin interface, similar to a Jones spring model, which replaces the continuity boundary conditions at the liquid - corrugated solid-plate interface. As the surrounding liquid is considered to be perfect, only one complex stiffness is used for the model of Jones. The selection of the plate guided mode and the test frequency are motivated by the detectability and non-interference with other modes. The spring stiffness is obtained by a best fit procedure, between the analytical solution and the results obtained by the finite elements method (FEM). One way ensuring the agreement of the two approaches, rheological and FEM, is to consider angular resonances provided by the transmission coefficients. Small changes in the parameters of the roughness keep the positions of the angular resonances of the plate practically unchanged, while at the same time large variations of the half width of the transmission coefficient curve is observed. The effect of corrugation parameters on the guided modes in the plate can be predicted by using the rheological model with the deduced spring complex stiffness. Copyright © 2016. Published by Elsevier B.V.

  6. Brittle Splitting Nails (Onychoschizia)

    MedlinePlus

    ... be divided into dry and brittle (too little moisture) and soft and brittle (often too much moisture). The usual cause is repeated wetting and drying ... that the nails may be getting too much moisture or being damaged by chemicals such as detergents, ...

  7. A Pilot Study: Nailing Indian Elections with the Indelible Ink Mark

    PubMed Central

    Abraham, Anil; Roga, Gillian; Thomas, Naveen

    2015-01-01

    Context: The indelible ink that's used in our elections was developed by National Physical Laboratories (NPL), Delhi in 1962, and has been used ever since. Though formulated by NPL, it is manufactured by Mysore Paints and Varnish Ltd. owned by the Karnataka Government. Earlier, the ink mark was applied on the cuticle but with effect from February 01, 2006 the ink is applied on the voter's left index fingernail from the distal end proximally until the cuticle using an applicator. This idea of the ink mark applied during elections was used as a simple tool to measure the rate of nail growth in a busy outpatient department of a Tertiary Hospital in South India. Aims: To assess the feasibility of using the ink mark during elections as a method of obtaining data of nail growth across the spectrum of the entire country. Subjects and Methods: In 74 patients presenting to a hospital, the rate of nail growth was measured. The voter's mark on the left index fingernail of patients during the recent elections was used as a marker for measuring the length of the nail. Results: The average rate of nail growth was 0.113 mm/day. The rate of nail growth was found to be more in females, younger individuals, pregnancy, patients on nutritional supplementation, psoriasis. Conclusion: This study which was conducted on 74 patients using the election ink mark successfully confirmed the possibility of using it as an efficient tool in measuring the rate of nail growth. The findings revealed the slightly higher rate of nail growth as compared to a study done by Rani et al. However, the limited sample size in this study was the major limitation. PMID:26677268

  8. Computational comparison of tibial diaphyseal fractures fixed with various degrees of prebending of titanium elastic nails and with and without end caps.

    PubMed

    Chen, Yen-Nien; Lee, Pei-Yuan; Chang, Chih-Han; Chang, Chih-Wei; Ho, Yi-Hung; Li, Chun-Ting; Peng, Yao-Te

    2016-10-01

    Elastic stable intramedullary nailing (ESIN) is a treatment strategy for the management of diaphyseal long-bone fractures in adolescents and children, but few studies have investigated the mechanical stability of tibial diaphyseal fractures treated with various degrees of prebending of the elastic nails. Therefore, the aim of this study was to compare the mechanical stability, including the gap deformation and nail dropping, of a tibia fracture with various fracture sites and fixed with various degrees of prebending of the elastic nails by the finite element method. Furthermore, the contribution of end caps to stability was taken into consideration in the simulation. A tibia model was developed with a transverse fracture at the proximal, middle and distal parts of the diaphysis, and fixed with three degrees of prebending of elastic nails, including those equal to, two times and three times the diameter of the intramedullary canal. The outer diameter of the nail used in the computation was 3.5mm, and the fractured tibia was fixed with two elastic double C-type nails. Furthermore, the proximal end of each nail was set to free or being tied to the surrounding bone by a constraint equation to simulate with or without using end caps. The results indicated that using end caps can prevent the fracture gap from collapsing by stopping the ends of the nails from dropping back in all prebending conditions and fracture patterns, and increasing the prebending of the nails to a degree three times the diameter of the canal reduced the gap shortening and the dropping distance of the nail end in those without using end caps under axial compression and bending. Insufficient prebending of the nails and not using end caps caused the gap to collapse and the nail to drop back at the entry point under loading. Using end caps or increasing the prebending of the nails to three times the diameter of the canal is suggested to stop the nail from dropping back and thus produce a more stable

  9. [Respiratory manifestations of yellow nail syndrome: report of two cases and literature review].

    PubMed

    Li, S; Huang, H; Xu, K; Xu, Z J

    2018-03-12

    Objective: To describe the clinical characteristics of respiratory manifestations of yellow nail syndrome. Methods: We conducted a retrospective analysis of 2 patients with respiratory diseases associated with yellow nail syndrome. Their clinical and chest radiological data were collected. We searched PubMed, Wanfang and CNKI databases with the keywords "yellow nail syndrome, yellow nail and lung" in Chinese and English. And the relevant literatures, including 6 articles in Chinese and 81 articles in English, were reviewed. Results: Our 2 patients were male, one 60 years old and the other 76. Typical yellow nails were present in their fingers, and one of them also showed toe yellow nails. One patient was admitted for refractory respiratory infection and he was diagnosed with diffuse bronchiectasis. The respiratory symptoms could be relieved with antibiotics according to the results of sputum microbiological analysis. The other patient was admitted for cough and exertional dyspnea, and refractory pleural effusions were revealed bilaterally. He received repeated effusion drainage by thoracentesis, and Octreotide was tried recently. A total of 373 cases were reviewed in Chinese and English literatures. Pleural effusions (152 cases) and diffuse bronchiectasis (121 cases) were the most common reported respiratory manifestations. Lymphoedema was present in almost all cases with pleural effusion associated with yellow nail syndrome, and the effusion was usually exudative and lymphocyte predominant. Pleurodesis and decortication were effective for them. But, somatostatin analogues had been tried effectively for these patients recently. On the other hand, literatures showed that diffuse bronchiectasis in yellow nail syndrome was less severe than idiopathic diffuse bronchiectasis, and might benefit from long-term macrolide antibiotics. Conclusions: Yellow nail syndrome is a very rare disorder. Besides yellow nail, respiratory manifestations are the main clinical

  10. Reamed versus unreamed intramedullary nailing for the treatment of femoral fractures

    PubMed Central

    Li, A-Bing; Zhang, Wei-Jiang; Guo, Wei-Jun; Wang, Xin-Hua; Jin, Hai-Ming; Zhao, You-Ming

    2016-01-01

    Abstract Background and objective: Intramedullary nailing is commonly used for treating femoral shaft fractures, one of the most common long bone fractures in adults. The reamed intramedullary nail is considered the standard implant for femoral fractures. This meta-analysis was performed to verify the superiority of reamed intramedullary nailing over unreamed intramedullary nailing in fractures of the femoral shaft in adults. Subgroup analysis of implant failure and secondary procedure was also performed. Methods: Electronic literature databases were used to identify relevant publications and included MEDLINE (Ovid interface), EMBASE (Ovid interface), and the Cochrane Central Register of Controlled Trials (CENTRAL; Wiley Online Library). The versions available on January 30, 2016, were utilized. Only human studies, which were designed as randomized controlled clinical trials, were included. Two authors independently evaluated the quality of original research publications and extracted data from the studies that met the criteria. Results: Around 8 randomized controlled trials involving 1078 patients were included. Reamed intramedullary nailing was associated with shorter time to consolidation of the fracture (SMD = –0.62, 95% CI = –0.89 to –0.35, P < 0.00001), lower secondary procedure rate (OR = 0.25, 95% CI 0.10–0.62, P = 0.003), lower nonunion rate (OR = 0.14, 95% CI = 0.05–0.40, P < 0.01), and lower delayed-union rate (OR = 0.19, 95% CI = 0.07–0.49, P < 0.01) compared to unreamed intramedullary nailing. The 2 groups showed no significant differences in risk of implant failure (OR = 0.50, 95% CI 0.14–1.74, P = 0.27), mortality risk (OR = 0.94, 95% CI 0.19–4.68, P = 0.94), risk of acute respiratory distress syndrome (ARDS; OR = 1.55, 95% CI 0.36–6.57, P = 0.55), or blood loss (SMD = 0.57, 95% CI = –0.22 to 1.36, P = 0.15). Conclusion: Reamed intramedullary nailing

  11. Chevron nails: a normal variant in the pediatric population.

    PubMed

    Delano, Sofia; Belazarian, Leah

    2014-01-01

    A 7-month-old girl was evaluated for V-shaped ridging of the fingernails consistent with chevron nails. Chevron nails are a normal variant in the pediatric population that is frequently outgrown. This case nicely demonstrates this normal finding that has so rarely been reported in the literature. © 2013 Wiley Periodicals, Inc.

  12. [RESEARCH PROGRESS IN COMPLICATIONS OF RETROGRADE INTRAMEDULLARY NAIL FIXATION FOR TIBIOTALOCALCANEAL ARTHRODESIS].

    PubMed

    Feng, Jun; Yu, Guangrong

    2015-09-01

    To review the cause, treatment, and prevention of complications of retrograde intramedullary nail fixation for tibiotalocalcaneal arthrodesis and enhance the recognition on the complications of tibiotalocalcaneal arthrodesis. The recent literature concerning intramedullary nail fixation for tibiotalocalcaneal arthrodesis was consulted and reviewed. There are intraoperative and postoperative complications of intramedullary nail fixation for tibiotalocalcaneal arthrodesis, and the causes, treatment, and prevention of complications are various. Progress of retrograde intramedullary nail fixation increases the successful rate of tibiotalocalcaneal arthrodesis. However, there is still a high complication rate, so strict preoperative assessment and skilled surgical technique are necessary to prevent complications.

  13. Complications of short versus long cephalomedullary nail for intertrochanteric femur fractures, minimum 1 year follow-up.

    PubMed

    Vaughn, Josh; Cohen, Eric; Vopat, Bryan G; Kane, Patrick; Abbood, Emily; Born, Christopher

    2015-05-01

    Hip fractures are becoming increasingly common resulting in significant morbidity, mortality and raising healthcare costs. Both short and long cephalomedullary devices are currently employed to treat intertrochanteric hip fractures. However, which device is optimal continues to be debated as each implant has unique characteristics and theoretical advantages. This study looked to identify rates of complications associated with both long and short cephalomedullary nails for the treatment of intertrochanteric hip fractures. We retrospectively reviewed charts from 2006 to 2011, and we identified 256 patients were identified with AO class 31.1-32.3 fractures. Sixty were treated with short nails and 196 with long nails. Radiographs and charts were then analysed for failures and hardware complications. Catastrophic failure and hardware complication rates were not statistically different between short or long cephalomedullary nails. The overall catastrophic failure rate was 3.1 %; there was a 5 % failure rate in the short-nail group compared with a 2.6 % failure rate in the long-nail group (p = 0.191). There was a 3.33 % secondary femur fracture rate in the short-nail group, compared with none in the long-nail cohort (p = 0.054). The rate of proximal fixation failure was 1.67 % for the short-nail group and 2.0 % in the long-nail group (p = 0.406). Our data suggests equivocal outcomes as measured by similar catastrophic failure rate between both short and long cephalomedullary nails for intertrochanteric femur fractures. However, there was an increased risk of secondary femur fracture with short cephalomedullary nails when compared to long nails that approached statistical significance.

  14. Habit tic nail deformity - a rare presentation in an 8 year old boy.

    PubMed

    El-Heis, S; Abadie, Al

    2016-11-15

    Habit tic nail deformity is a nail dystrophy resulting from habitual, repetitive trauma to the nail. It is usually acquired in adulthood, however, we report a case of habit tic nail deformity in an 8 year old boy. The diagnosis was made clinically with further history revealing that the boy repeatedly rubbed his thumbnails and pushed the cuticles. Emollient cream (Balneum®) was recommended twice daily and both the patient and his mother were educated on the behavioral nature of this condition. There was marked improvement at 6 months of treatment and further improvement at 12 months.We note that habit tic nail deformity is not exclusive to adults. Diagnosis can be made clinically. History and physical examination provide valuable clues and psychosocial links must be explored and addressed. Management is challenging and compliance with treatment is variable. Patient education, barrier methods, and behavioral therapy can be helpful in preventing further trauma to the nails.

  15. Brittle Splitting Nails (Onychoschizia)

    MedlinePlus

    ... more common in women. Only very rarely are internal disease or vitamin deficiencies the reason (iron deficiency is the most common). One tip is that if the fingernails split, but the toenails are strong, then an external factor is the cause. Basically brittle nails can be ...

  16. Nail Ridges: Cause for Concern?

    MedlinePlus

    ... of a health problem? Answers from Lawrence E. Gibson, M.D. It depends on the direction of ... indicate an underlying health condition. With Lawrence E. Gibson, M.D. Habif TP. Nail diseases. In: Clinical ...

  17. Revision Tibiotalocalcaneal Arthrodesis With a Pseudoelastic Intramedullary Nail.

    PubMed

    Latt, L Daniel; Smith, Kathryn Elizabeth; Dupont, Kenneth Michael

    2017-02-01

    Hindfoot (tibiotalocalcaneal or TTC) arthrodesis is commonly used to treat concomitant arthritis of the ankle and subtalar joints. Simultaneous fusion of both joints can be difficult to achieve especially in patients with impaired healing due to smoking, diabetes mellitus, or Charcot neuroarthropathy. Conventional intramedullary fixation devices allow for compression to be applied at the time of surgery, but this compression can be lost due to bone resorption or settling, leading to impaired healing. In contrast, the novel pseudoelastic intramedullary nail is designed to maintain compression at the arthrodesis sites throughout the healing process by the use of an internal pseudoelastic element. We present 2 cases of revision TTC arthrodesis using the pseudoelastic intramedullary nail. In the first case, an 80-year-old diabetic man with previous ankle and failed subtalar fusion with screws underwent revision TTC arthrodesis. In the second case, a 66-year-old man with Charcot neuroarthropathy and a failed TTC arthrodesis with a static intramedullary nail underwent revision tibiotalar arthrodesis. In both cases, computed tomography scan demonstrated successful union and patients were allowed full weight bearing by 3 months after surgery. These cases provide early evidence that sustained compression via an intramedullary nail can lead to rapid successful hindfoot fusion when standard approaches have failed. Therapeutic, Level IV: Case study.

  18. Retrograde nailing for distal third femoral shaft fractures: a prospective study.

    PubMed

    Acharya, K N; Rao, M R

    2006-12-01

    To evaluate the postoperative knee function and results of unreamed retrograde nailing for distal third femoral shaft fractures. Between January 2002 and 2003 inclusive, a consecutive series of 27 patients (with 28 fractures) who underwent retrograde nailing were prospectively evaluated. Outcome measures were union time, initiation of weight bearing, deformity and shortening, functional length of the nail, knee function assessed using a modified Knee Society Knee Score. Correlations between union time and other variables were also studied. In these patients 26 (93%) of the 28 fractures achieved union, of which 5 underwent dynamisation; the mean union time for the other 21 fractures was 4.4 months. Angular malalignment was present in 4 patients and shortening in 4 others. There was negligible correlation between union time and variables of nail-canal diameter mismatch, functional length of nail, fracture geometry, or initiation of partial weight bearing ambulation. Knee flexion of more than 100 degrees was achieved in 26 patients. 19 patients had anterior knee pain and 10 had instability. By the end of one year, excellent or good scores for pain and function were recorded in 77% and 73% respectively, of the 26 patients. In view of such favourable union rates but significant deterioration in overall knee joint function, at best retrograde nailing is a reliable alternative in the management of selected complicated fractures of the distal femoral shaft.

  19. Does the Angle of the Nail Matter for Pertrochanteric Fracture Reduction? Matching Nail Angle and Native Neck-Shaft Angle.

    PubMed

    Parry, Joshua A; Barrett, Ian; Schoch, Bradley; Yuan, Brandon; Cass, Joseph; Cross, William

    2018-04-01

    To determine whether fixation of pertrochanteric hip fractures with cephalomedullary nails (CMNs) with a neck-shaft angle (NSA) less than the native NSA affects reduction and lag screw cutout. Retrospective comparative study. Level I trauma center. Patients treated with a CMN for unstable pertrochanteric femur fractures (OTA/AO 31-A2.2 and 31-A2.3) between 2005 and 2014. CMN fixation. NSA reduction and lag screw cutout. Patients fixed with a nail angle less than their native NSA were less likely to have good reductions [17% vs. 60%, 95% confidence interval (CI), -63% to -18%; P = 0.0005], secondary to more varus reductions (41% vs. 10%, 95% CI, 9%-46%; P = 0.01) and more fractures with ≥4 mm of displacement (63% vs. 35%, 95% CI, 3%-49%; P = 0.03). The cutout was not associated with the use of a nail angle less than the native NSA (60% vs. 76%, 95% CI, -56% to 18%; P = 0.5), varus reductions (60% vs. 32%, 95% CI, -13% to 62%; P = 0.3), or poor reductions (20% vs. 17%, 95% CI, -24% to 44%; P = 1.0). The fixation of unstable pertrochanteric hip fractures with a nail angle less than the native NSA was associated with more varus reductions and fracture displacement but did not affect the lag screw cutout. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  20. Allergic contact dermatitis caused by (meth)acrylates in nail cosmetic products in users and nail technicians - a 5-year study.

    PubMed

    Raposo, Inês; Lobo, Inês; Amaro, Cristina; Lobo, Maria de Lurdes; Melo, Helena; Parente, Joana; Pereira, Teresa; Rocha, Joana; Cunha, Ana P; Baptista, Armando; Serrano, Pedro; Correia, Teresa; Travassos, Ana R; Dias, Margarida; Pereira, Fátima; Gonçalo, Margarida

    2017-12-01

    The increasing use of long-lasting nail aesthetic products has led to a growing number of cases of allergic contact dermatitis (ACD) caused by (meth)acrylates in recent years. To provide information on ACD caused by (meth)acrylates related to nail cosmetic products. We retrospectively reviewed files of patients with ACD caused by (meth)acrylates related to nail cosmetic products, who were patch tested between January 2011 and December 2015 in 13 departments of dermatology in Portugal. Two-hundred and thirty cases of ACD caused by (meth)acrylates (55 technicians, 56 consumers, and 119 with mixed exposure) had been documented, mostly as chronic hand eczema (93%). The most common sensitizers were: 2-hydroxyethyl methacrylate (HEMA), which was positive in 90% of the tested patients, 2-hydroxypropyl methacrylate (HPMA), which was positive in 64.1%, and ethyleneglycol dimethacrylate, which was positive in 54.5%. HEMA and HPMA were the most frequent positive allergens. HEMA, which identified 90% of cases, can be considered to be a good screening allergen. The high number of cases of ACD caused by (meth)acrylates in nail cosmetic products certainly warrants better preventive measures at the occupational level, and specific regulation in the field of consumer safety. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. [The present study situation and application prospect of nail analysis for abused drugs].

    PubMed

    Chen, Hang; Xiang, Ping; Shen, Min

    2010-10-01

    In forensic toxicology analysis, various types of biological samples have their own special characteristics and scope of applications. In this article, the physiological structure of nails, methods for collecting and pre-processing samples, and for analyzing some poisons and drugs in the nails are reviewed with details. This paper introduces the influence factors of drug abuse of the nails. The prospects of its further applications are concluded based on the research results. Nails, as an unconventional bio-sample without general application, show great potential and advantages in forensic toxicology.

  2. Computational models for the nonlinear analysis of reinforced concrete plates

    NASA Technical Reports Server (NTRS)

    Hinton, E.; Rahman, H. H. A.; Huq, M. M.

    1980-01-01

    A finite element computational model for the nonlinear analysis of reinforced concrete solid, stiffened and cellular plates is briefly outlined. Typically, Mindlin elements are used to model the plates whereas eccentric Timoshenko elements are adopted to represent the beams. The layering technique, common in the analysis of reinforced concrete flexural systems, is incorporated in the model. The proposed model provides an inexpensive and reasonably accurate approach which can be extended for use with voided plates.

  3. Modelling ultrasound guided wave propagation for plate thickness measurement

    NASA Astrophysics Data System (ADS)

    Malladi, Rakesh; Dabak, Anand; Murthy, Nitish Krishna

    2014-03-01

    Structural Health monitoring refers to monitoring the health of plate-like walls of large reactors, pipelines and other structures in terms of corrosion detection and thickness estimation. The objective of this work is modeling the ultrasonic guided waves generated in a plate. The piezoelectric is excited by an input pulse to generate ultrasonic guided lamb waves in the plate that are received by another piezoelectric transducer. In contrast with existing methods, we develop a mathematical model of the direct component of the signal (DCS) recorded at the terminals of the piezoelectric transducer. The DCS model uses maximum likelihood technique to estimate the different parameters, namely the time delay of the signal due to the transducer delay and amplitude scaling of all the lamb wave modes due to attenuation, while taking into account the received signal spreading in time due to dispersion. The maximum likelihood estimate minimizes the energy difference between the experimental and the DCS model-generated signal. We demonstrate that the DCS model matches closely with experimentally recorded signals and show it can be used to estimate thickness of the plate. The main idea of the thickness estimation algorithm is to generate a bank of DCS model-generated signals, each corresponding to a different thickness of the plate and then find the closest match among these signals to the received signal, resulting in an estimate of the thickness of the plate. Therefore our approach provides a complementary suite of analytics to the existing thickness monitoring approaches.

  4. Anatomic structures at risk: curved hindfoot arthrodesis nail--a cadaveric approach.

    PubMed

    Knight, Timothy; Rosenfeld, Peter; Jones, Ioan Tudur; Clark, Callum; Savva, Nick

    2014-01-01

    Retrograde intramedullary nailing of the hindfoot and ankle is an established procedure for salvage of severe foot and ankle deformity, arthritis, tumor, and instability. In the present study, retrograde hindfoot (tibiotalocalcaneal) arthrodesis nailing was performed using a standardized technique on 7 cadaver specimens by trained senior surgeons. The specimens were then dissected to determine the distance of the subcalcaneal structures at risk from the insertion point of the nail. The findings showed that the distance of the lateral neurovascular bundle from the edge of the nail was 6.5 (range 3.5 to 8, 95% confidence interval 5.9 to 7.1) mm. No neurovascular bundle was compromised, and all were within a previously described "safe window." Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Venting during prophylactic nailing for femoral metastases: current orthopedic practice.

    PubMed

    Dalgorf, Dustin; Borkhoff, Cornelia M; Stephen, David J G; Finkelstein, Joel; Kreder, Hans J

    2003-12-01

    Reamed intramedullary nailing, recommended for impending fracture of a femur weakened by bone metastases, causes a rise in intramedullary pressure and increases the risk of a fat embolism syndrome. The pressure can be equalized by the technique of venting--drilling a hole into the distal cortex of the femur. Our objective was to study the current practice of orthopedic surgeons in Ontario with respect to venting during prophylactic intramedullary nailing for an impending femoral fracture due to bone metastases. We mailed a questionnaire to all orthopedic surgeons from the Province of Ontario listed in the 1999 Canadian Medical Directory or on the Canadian Orthopaedic Association membership list, asking if they vent when prophylactically nailing an impending pathologic femoral fracture. The responses were modelled as a function of surgeon volume and year of graduation. Of the 415 surveys mailed, 223 (54%) surgeons responded. Of these, 81% reported having prophylactically treated a femoral metastatic lesion during the previous year; 67% treated 1 to 3 metastatic lesions and 14% treated more than 3; 19% did not treat a metastatic femoral lesion prophylactically. Over two-thirds of surgeons had never considered venting, whereas one-third always or sometimes vented the femoral canal. More recent graduates were 3 times more likely to vent than earlier (before 1980) graduates (odds ratio [OR] = 3.2, 95% confidence interval [CI] 1.6-6.5) as were those who treat a greater number of impending fractures (OR = 1.4, 95% CI 1.1-1.7). Although there is a theoretical rationale for routine venting, there is disagreement among Ontario orthopedic surgeons regarding the use of this technique during prophylactic nailing for femoral metastatic lesions. Prospective evidence will be required to warrant a change in the standard of care.

  6. Creep behavior of soil nail walls in high plasticity index (PI) soils : technical report.

    DOT National Transportation Integrated Search

    2017-04-01

    An aspect of particular concern in the Geotechnical Engineering Circular No. 7: Soil Nail Walls (i.e., the soil : nail wall manual and construction guidelines) is the creep behavior of soil nail systems in high-plasticity : clays. This research proje...

  7. Extraction of the Wichita Fusion Nail after Knee Arthrodesis.

    PubMed

    Neuts, Ann-Sophie; Lammens, Johan; Stuyck, Jose

    2016-01-01

    To avoid a new exposition and partial damage of a knee arthrodesis site due to the removal of the Wichita fusion nail (WFN), a new extraction technique was developed, using a femoral osteotomy at the proximal end of the nail. Fixing the osteotomy with an Ilizarov frame offered the possibility to perform an additional correction of length and/or alignment if necessary.

  8. Intramedullary nailing of clavicular midshaft fractures in adults using titanium elastic nail.

    PubMed

    Chen, Qing-Yu; Kou, Dong-Quan; Cheng, Xiao-Jie; Zhang, Wei; Wang, Wei; Lin, Zhang-Qin; Cheng, Shao-Wen; Shen, Yue; Ying, Xiao-Zhou; Peng, Lei; Lv, Chuan-Zhu

    2011-01-01

    Studies showed elastic stable intramedullary nailing (ESIN) of displaced midclavicular fractures has excellent outcomes, as well as high complication rates and specific problems. The aim was to discuss ESIN of midshaft clavicular fractures. Totally 60 eligible patients (aged 18-63 years) were randomized to either ESIN group or non-operative group between January 2007 and May 2008. Clavicular shortening was measured after trauma and osseous consolidation. Radiographic union and complications were assessed. Function analysis including Constant shoulder scores and disabilities of the arm, shoulder and hand (DASH) scores were performed after a 15-month follow-up. ESIN led to a signifcantly shorter time to union, especially for simple fractures. In ESIN group, all patients got fracture union, of which 5 cases had medial skin irritation and 1 patient needed revision surgery because of implant failure. In the nonoperative group, there were 3 nonunion cases and 2 symptomatic malunions developed requiring corrective osteotomy. At 15 months after intramedullary stabilization, patients in the ESIN group were more satisfied with the appearance of the shoulder and overall outcome, and they benefited a lot from the great improvement of post-traumatic clavicular shortening. Furthermore, DASH scores were lower and Constant scores were significantly higher in contrast to the non-operative group. ESIN is a safe minimally invasive surgical technique with lower complication rate, faster return to daily activities, excellent cosmetic and better functional results, restoration of clavicular length for treating mid-shaft clavicular fractures, resulting in high overall satisfaction, which can be regard as an alternative to plate fixation or nonoperative treatment of mid-shaft clavicular fractures.

  9. Health hazard evaluation report HETA 90-048-2253, Haute Nails, Norman, Oklahoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almaguer, D.; Blade, L.M.

    In response to a request from the owner/operator of the Haute Nails Salon, Norman, Oklahoma, an evaluation was undertaken of possible chemical exposures from the use of nail sculpturing products. Haute Nails was an artificial nail sculpturing and tanning salon employing two full time nail sculpturers and four part time receptionists. The company was located on the first floor of a two story brick building. Long term general area air sampling was conducted for volatile organic chemicals, formaldehyde, and methacrylates; personal breathing zone air sampling was conducted for methacrylates. Ethyl-methacrylate concentrations in long term samples ranged from 10.3 to 14.1more » mg/cu m. Breathing zone concentrations of ethyl-methacrylate were 128 mg/cu m for a 7 minute sample and 78.9 mg/cu m for a 14 minute sample during nail sculpturing. Carbon-dioxide measurements exceeded the recommended level of 1000 parts per million. The authors conclude that there were no overexposures to ethyl-methylacrylate during the evaluation. The heating and air conditioning system did not provide for the mechanical exchange of outside air and no exhaust fans were located in the area served by the system. The authors recommend that an outside air supply duct be added to the present system.« less

  10. Hierarchic models for laminated plates. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Actis, Ricardo Luis

    1991-01-01

    Structural plates and shells are three-dimensional bodies, one dimension of which happens to be much smaller than the other two. Thus, the quality of a plate or shell model must be judged on the basis of how well its exact solution approximates the corresponding three-dimensional problem. Of course, the exact solution depends not only on the choice of the model but also on the topology, material properties, loading and constraints. The desired degree of approximation depends on the analyst's goals in performing the analysis. For these reasons models have to be chosen adaptively. Hierarchic sequences of models make adaptive selection of the model which is best suited for the purposes of a particular analysis possible. The principles governing the formulation of hierarchic models for laminated plates are presented. The essential features of the hierarchic models described models are: (1) the exact solutions corresponding to the hierarchic sequence of models converge to the exact solution of the corresponding problem of elasticity for a fixed laminate thickness; and (2) the exact solution of each model converges to the same limit as the exact solution of the corresponding problem of elasticity with respect to the laminate thickness approaching zero. The formulation is based on one parameter (beta) which characterizes the hierarchic sequence of models, and a set of constants whose influence was assessed by a numerical sensitivity study. The recommended selection of these constants results in the number of fields increasing by three for each increment in the power of beta. Numerical examples analyzed with the proposed sequence of models are included and good correlation with the reference solutions was found. Results were obtained for laminated strips (plates in cylindrical bending) and for square and rectangular plates with uniform loading and with homogeneous boundary conditions. Cross-ply and angle-ply laminates were evaluated and the results compared with those of

  11. [Results of femoral lengthening over an intramedullary nail and external fixator].

    PubMed

    Jasiewicz, Barbara; Kacki, Wojciech; Tesiorowski, Maciej; Potaczek, Tomasz

    2008-01-01

    Current techniques of operative limb lengthening usually are based on distraction osteogenesis. One of the techniques is limb lengthening over an intramedullary nail. The goal of this study is to evaluate the results of femoral lengthening over an intramedullary nail. Between 1999 and 200619 femoral "over nail" lengthenings were performed. There were 7 males and 12 females. Mean patients' age at surgery was 15.8 years, and mean initial femoral shortening was 5.1 cm. Operative technique consisted of one-stage implantation of intramedullary nail and external fixator. Ilizarov apparatus was used in 9 patients, monolateral fixator in 10 cases--ORTHOFIX in 9 patients, Wagner fixator--in 1 patient. Intramedullary nail was locked proximally with screws or Schanz pins from external fixator. After distraction phase, external fixator was removed and distal locking screws were applied. Evaluation criteria: obtained lengthening, time of external fixator, treatment time, healing index, external fixation index, range of motion in hip and knee joints and complications according to Paley. The mean lengthening was 4.6 cm, and mean distraction time was 66.6 days. Mean time of external fixation was 115.5 days, and external fixation index was 26.2 days for centimeter. Healing index was 36.9 days for centimeter. In cases with monolateral fixator, healing index did not differ with the whole group. During treatment 18 complications occurred, for a rate of 0.9 complication per segment. Lengthening over an intramedullary nail reduces the time of external fixator. Over nail femoral lengthening can prevent axis deviation following regenerate bending. Complication rate is similar to lengthenings with the classic Ilizarov technique. There are no differences in the treatment time in relation to the type of external fixator.

  12. Effects of reinforcement without extinction on increasing compliance with nail cutting: A systematic replication.

    PubMed

    Dowdy, Art; Tincani, Matt; Nipe, Timothy; Weiss, Mary Jane

    2018-06-17

    Personal hygiene routines, such as nail cutting, are essential for maintaining good health. However, individuals with autism spectrum disorder (ASD) and other developmental disabilities often struggle to comply with essential, personal hygiene routines. We conducted a systematic replication of Schumacher and Rapp (2011), Shabani and Fisher (2006), and Bishop et al. (2013) to evaluate an intervention that did not require escape extinction for increasing compliance with nail cutting. With two adolescents diagnosed with ASD who resisted nail cutting, we evaluated the effects of delivering a preferred edible item contingent on compliance with nail cutting. Results indicated that the treatment reduced participants' escape responses and increased their compliance with nail cutting. © 2018 Society for the Experimental Analysis of Behavior.

  13. [Electromagnetic navigation interlocking intramedullary nail technology for treatment of femoral shaft fractures].

    PubMed

    Zuo, Kangkang; Qin, Wei; Guo, Qing; Palati-Ababaikeli; Qiao, Peiliu; Shen, Mingquan; Yin, Lele; Pan, Qilin; Xu, Xiaoxiong

    2014-10-01

    To explore the value of electromagnetic navigation interlocking intramedullary nail in the treatment of femoral shaft fracture. Between July 2012 and October 2013, 53 cases of femoral shaft fracture were treated. There were 40 males and 13 females, aged 16-52 years (mean, 38.3 years). The causes of injury were traffic accident in 28 cases, falling from height in 11 cases, falling in 7 cases, crush injury in 4 cases, and other in 3 cases. Of 53 cases, there were 3 cases of open fracture (Gustilo I degree) and 50 cases of closed fracture. Fracture was located in the proximal femur in 17 cases, middle femur in 29 cases, and distal femur in 7 cases. According to Winquist classification, 7 cases were rated as type I, 8 cases as type II, 22 cases as type III, and 16 cases as type IV; according to AO classification, 18 cases were rated as type 32-A, 28 cases as type 32-B, and 7 cases as type 32-C. The time from injury to operation was 3-11 days (mean, 5 days). Distal interlocking intramedullary nail was implanted using electromagnetic navigation. The distal locking nail operation with interlocking intramedullary nail was successfully completed under electromagnetic navigation; the one-time success rate of distal locking nail operation reached 100%; and the locking nail time was 5.0-9.5 minutes (mean, 7.0 minutes). Healing of incision by first intention was obtained after operation, and no complication of skin necrosis, infection, and sinus tract occurred. Fifty-three cases were all followed up 5-12 months (mean, 9 months). One case had hip pain and weaken middle gluteal muscle strength, and the symptoms disappeared after removing the nail. During the follow-up period, no broken nails, nail exit, infection, or re-fracture occurred. All fractures achieved clinical healing, and the healing time was 8-22 weeks (mean, 14.5 weeks). In 49 patients followed up 8 months, the Lysholm score was excellent in 44 cases, good in 4 cases, and acceptable in 1 case, with an excellent and

  14. Refractures of the paediatric forearm with the intramedullary nail in situ.

    PubMed

    van Egmond, Pim W; van der Sluijs, Hans A; van Royen, Barend J; Saouti, Rachid

    2013-09-24

    Forearm fractures in children are common. When conservative treatment fails, internal fixation with Elastic Stable Intramedullary Nailing (ESIN) become the first choice in the operative treatment of diaphyseal forearm shaft fractures. Refractures with the intramedullary nail in situ are known to occur but formal guidelines to guide management in such fractures are lacking. We present a well-documented case of a radius midshaft refracture in a 12-year-old boy with the intramedullary nail in situ, managed by closed reduction. Literature is reviewed for this type of complication, the treatment of 30 similar cases is discussed and a treatment strategy is defined. The refracture of the paediatric forearm fracture with the intramedullary nail in situ is a rare, but probably under recognised complication which is observed in approximately 2.3% of the study population. Closed reduction may be considered in these cases.

  15. Is intramedullary nailing applicable for distal tibial fractures with ankle joint extension?

    PubMed

    Beytemür, Ozan; Albay, Cem; Adanır, Oktay; Yüksel, Serdar; Güleç, Mehmet Akif

    2016-12-01

    This study aims to evaluate the functional and radiographic results and treatment complications of AO/OTA (Arbeitsgemeinschaft fur Osteosynthesefragen/Orthopaedic Trauma Association) type 43C1 and C2 fractures treated with intramedullary nailing. We retrospectively evaluated 35 AO/OTA type 43C1 and C2 patients (26 males, 9 females; mean age 39.8±16.9 years; range 19 to 82 years) treated with intramedullary nailing. Two interfragmentary screws out of nail were applied in 10 patients (29%), while one interfragmentary screw out of nail was applied in 17 patients (49%). Intramedullary nailing was applied in eight patients (23%) without external screws. Fracture union, union time, alignment problems, and complications were evaluated. Clinical evaluation of patients was conducted using the Olerud and Molander score and by measuring the ankle joint range of motion. Union was achieved in all 35 patients. Mean union time was 16.5±2.8 weeks (range 12 to 24 weeks) and mean Olerud and Molander score was 88±8.24. Varus deformity was detected in one patient, valgus deformity was detected in two patients, and rotation deformity was detected in one patient. Superficial infection was detected in three patients (9%). Deep infection was not detected in any patient. Intramedullary nailing is not contraindicated for simple intra-articular distal tibial fractures. In these fractures, intramedullary nailing performed in accordance with its technique, with an additional percutaneous screw if necessary, is a successful treatment option with high fracture union rates, high functional results, and low complication rates.

  16. Extraction of the Wichita Fusion Nail after Knee Arthrodesis

    PubMed Central

    Neuts, Ann-Sophie; Lammens, Johan; Stuyck, Jose

    2016-01-01

    To avoid a new exposition and partial damage of a knee arthrodesis site due to the removal of the Wichita fusion nail (WFN), a new extraction technique was developed, using a femoral osteotomy at the proximal end of the nail. Fixing the osteotomy with an Ilizarov frame offered the possibility to perform an additional correction of length and/or alignment if necessary. PMID:28529847

  17. Outcome of intramedullary interlocking SIGN nail in tibial diaphyseal fracture.

    PubMed

    Khan, Irfanullah; Javed, Shahzad; Khan, Gauhar Nawaz; Aziz, Amer

    2013-03-01

    To determine the outcome of intramedullary interlocking surgical implant generation network (SIGN) nail in diaphyseal tibial fractures in terms of union and failure of implant (breakage of nail or interlocking screws). Case series. Orthopaedics and Spinal Surgery, Ghurki Trust Teaching Hospital, Lahore Medical and Dental College, Lahore, from September 2008 to August 2009. Fifty patients aged 14 - 60 years, of either gender were included, who had closed and Gustilo type I and II open fractures reported in 2 weeks, whose closed reduction was not possible or was unsatisfactory and fracture was located 7 cm below knee joint to 7 cm above ankle joint. Fractures previously treated with external fixator, infected fractures and unfit patients were excluded. All fractures were fixed with intramedullary interlocking SIGN nail and were followed clinically and radiographically for union and for any implant failure. Forty one (88%) patients had united fracture within 6 months, 5 (10%) patients had delayed union while 4 (8%) patients had non-union. Mean duration for achieving union was 163 + 30.6 days. Interlocking screws were broken in 2 patients while no nail was broken in any patient. Intramedullary interlocking nailing is an effective measure in treating closed and grade I and II open tibial fractures. It provides a high rate of union less complications and early return to function.

  18. Patterns of clinical nail appearances in patients with cutaneous psoriasis

    PubMed Central

    MARINA, ELENA MIHAELA; BOTAR-JID, CAROLINA; BOLBOACA, SORANA DANIELA; ROMAN, IULIA IOANA; SENILA, CORINA SIMONA; MIHU, CARMEN MIHAELA; TATARU, DUMITRU ALEXANDRU

    2017-01-01

    Background and aim Nail manifestations are often an overlooked aspect in psoriatic disease, cutaneous and joint involvement being far more often reported and investigated. The reported prevalence of nail changes varies in literature, specific fingernail clinical features having different degrees of occurrence. The aim of this study was to describe specific clinical patterns of fingernail alterations in adult patients with plaque-type psoriasis in a university hospital in the North-West of Romania. Methods Clinical data of 35 patients with fingernail psoriasis were collected and analyzed. Psoriasis Area and Severity Index (PASI) and Nail Psoriasis Severity Index (NAPSI) scores were used to quantify disease extension in each patient. Results PASI score proved linearly correlated with NAPSI score (p<0.05). The age of onset of fingernail psoriasis was positively correlated with age of onset cutaneous psoriasis (p<0.0001). Furthermore, the duration of cutaneous involvement and NAPSI proved significantly related (p<0.05). The third fingernail in the right hand and first fingernail in the left hand were in most of the cases severely affected. The most common observed nail pattern was pitting, followed by salmon patches and subungual hyperkeratosis. Conclusion Important nail changes appear even in moderate forms of cutaneous psoriasis. Particular localization of specific fingernail psoriasis pattern enables the possibility of detecting early stage disease. PMID:28246493

  19. Tibial lengthening over humeral and tibial intramedullary nails in patients with sequelae of poliomyelitis: a comparative study.

    PubMed

    Chen, Daoyun; Chen, Jianmin; Jiang, Yao; Liu, Fanggang

    2011-06-01

    Leg discrepancy is common after poliomyelitis. Tibial lengthening is an effective way to solve this problem. It is believed lengthening over a tibial intramedullary nail can provide a more comfortable lengthening process than by the conventional technique. However, patients with sequelae of poliomyelitis typically have narrow intramedullary canals allowing limited space for inserting a tibial intramedullary nail and Kirschner wires. To overcome this problem, we tried using humeral nails instead of tibial nails in the lengthening procedure. In this study, we used humeral nails in 20 tibial lengthening procedures and compared the results with another group of patients who were treated with tibial lengthening over tibial intramedullary nails. The mean consolidation index, percentage of increase and external fixation index did not show significant differences between the two groups. However, less blood loss and shorter operating time were noted in the humeral nail group. More patients encountered difficulty with the inserted intramedullary nail in the tibial nail group procedure. The complications did not show a statistically significant difference between the two techniques on follow-up. In conclusion, we found the humeral nail lengthening technique was more suitable in leg discrepancy patients with sequelae of poliomyelitis.

  20. Nail care feature gets to the heart of core nursing skills.

    PubMed

    Lindsay, Margot

    2009-07-07

    Thank you for drawing attention to the importance of personal hygiene in nail care (art&science June 17). Authors Bridget Malkin and Pat Berridge discuss the subject in depth and address the confusion over who should perform nail care for patients.

  1. The Chinese Nail Murders: forensic medicine in Imperial China.

    PubMed Central

    Summers, W. C.

    1999-01-01

    Robert van Gulik was a respected Dutch sinologist and author who first translated a collection of traditional Chinese detective stories into English and then created additional fictional stories based on the same characters and setting in the Tang dynasty. One of these stories, The Chinese Nail Murders, draws on van Gulik's professional interest in law and his knowledge of early Chinese works on forensic medicine. This novel develops a common theme in Chinese detective fiction, murder by a nail wound to the head. The difficulty in detection of this mode of violence posed a particular problem for the examining magistrate because postmortem examination was mostly limited to external observations. This essay compares the development of Chinese and Western forensic medicine in the context of the nail murder motif. PMID:11138936

  2. [Comparison of LCP and locked intramedullary nailing fixation in treatment of tibial diaphysis fractures].

    PubMed

    Huang, Peng; Tang, Peifu; Yao, Qi

    2007-11-01

    To evaluate the treatment results of LCP and locked intramedullary nailing for tibial diaphysis fractures. From October 2003 to April 2006, 55 patients with tibial diaphysis fractures (58 fractures) were treated. Of them there were 39 males and 16 females with an average of 39 years years ( 14 to 62 years). The fractures were on the left side in 27 patients and on the right side in 31 patients (3 patients had bilateral involvement). Thirty-four fractures were treated by intramedullary nailing (intramedullary nailing group) and 24 fractures by LCP fixation (LCP group). The average disease course was 3 days (intramedullary nailing group) and 3.1 days (LCP group). The operation time, the range of motion of knee and ankle joints, fracture healing time, and complications were evaluated. The patients were followed up 8-26 months (13 months on average). The operation time was 84.0+/-9.2 min (intramedullary nailing group) and 69.0+/-8.4 min (LCP group); the average cost in hospital was yen 19,297.78 in the intramedullary nailing group and yen 14,116.55 in the LCP group respectively, showing significant differences (P < 0.05). The flexion and extension of knee joint was 139.0 +/- 3.7 degrees and 4.0 +/- 0.7 degrees in intramedullary nailing group and 149.0+/-4.2 degrees and 0+/-0.4 degrees in LCP group, showing no significant difference (P>0.05). The doral flexion and plantar flexion of ankle joint were 13.0+/-1.7 degrees and 41.0+/-2.6 degrees in intramedullary nailing group, and 10.0+/-1.4 degrees and 44.0+/-2.3 degrees in LCP group, showing no significant differences (P>0.05). The mean healing time was 3.3 months in intramedullary nailing group, and 3. 1 months in LCP group. Length discrepancy occurred in 1 case (2.5 cm), delayed union in 1 case and nailing end trouble in 3 cases in intramedullary nailing group; moreover rotation deformity occurred 1 case and anterior knee pain occurred in 6 cases (17.1%). One angulation and open fracture developed osteomyelitis in 1

  3. Habit Reversal versus Object Manipulation Training for Treating Nail Biting: A Randomized Controlled Clinical Trial

    PubMed Central

    Ghanizadeh, Ahmad; Bazrafshan, Amir; Dehbozorgi, Gholamreza

    2013-01-01

    Objective This is a parallel, three group, randomized, controlled clinical trial, with outcomes evaluated up to three months after randomization for children and adolescents with chronic nail biting. The current study investigates the efficacy of habit reversal training (HRT) and compares its effect with object manipulation training (OMT) considering the limitations of the current literature. Method Ninety one children and adolescents with nail biting were randomly allocated to one of the three groups. The three groups were HRT (n = 30), OMT (n = 30), and wait-list or control group (n = 31). The mean length of nail was considered as the main outcome. Results The mean length of the nails after one month in HRT and OMT groups increased compared to the waiting list group (P < 0.001, P < 0.001, respectively). In long term, both OMT and HRT increased the mean length of nails (P < 0.01), but HRT was more effective than OMT (P < 0.021). The parent-reported frequency of nail biting did show similar results as to the mean length of nails assessment in long term. The number of children who completely stopped nail biting in HRT and OMT groups during three months was 8 and 7, respectively. This number was zero during one month for the wait-list group. Conclusion This trial showed that HRT is more effective than wait-list and OMT in increasing the mean length of nails of children and adolescents in long terms. PMID:24130603

  4. The SIGN nail for knee fusion: technique and clinical results

    PubMed Central

    Anderson, Duane Ray; Anderson, Lucas Aaron; Haller, Justin M.; Feyissa, Abebe Chala

    2016-01-01

    Purpose: Evaluate the efficacy of using the SIGN nail for instrumented knee fusion. Methods: Six consecutive patients (seven knees, three males) with an average age of 30.5 years (range, 18–50 years) underwent a knee arthrodesis with SIGN nail (mean follow-up 10.7 months; range, 8–14 months). Diagnoses included tuberculosis (two knees), congenital knee dislocation in two knees (one patient), bacterial septic arthritis (one knee), malunited spontaneous fusion (one knee), and severe gout with 90° flexion contracture (one knee). The nail was inserted through an anteromedial entry point on the femur and full weightbearing was permitted immediately. Results: All knees had clinical and radiographic evidence of fusion at final follow-up and none required further surgery. Four of six patients ambulated without assistive device, and all patients reported improved overall physical function. There were no post-operative complications. Conclusion: The technique described utilizing the SIGN nail is both safe and effective for knee arthrodesis and useful for austere environments with limited fluoroscopy and implant options. PMID:27163095

  5. The SIGN nail for knee fusion: technique and clinical results.

    PubMed

    Anderson, Duane Ray; Anderson, Lucas Aaron; Haller, Justin M; Feyissa, Abebe Chala

    2016-02-05

    Evaluate the efficacy of using the SIGN nail for instrumented knee fusion. Six consecutive patients (seven knees, three males) with an average age of 30.5 years (range, 18-50 years) underwent a knee arthrodesis with SIGN nail (mean follow-up 10.7 months; range, 8-14 months). Diagnoses included tuberculosis (two knees), congenital knee dislocation in two knees (one patient), bacterial septic arthritis (one knee), malunited spontaneous fusion (one knee), and severe gout with 90° flexion contracture (one knee). The nail was inserted through an anteromedial entry point on the femur and full weightbearing was permitted immediately. All knees had clinical and radiographic evidence of fusion at final follow-up and none required further surgery. Four of six patients ambulated without assistive device, and all patients reported improved overall physical function. There were no post-operative complications. The technique described utilizing the SIGN nail is both safe and effective for knee arthrodesis and useful for austere environments with limited fluoroscopy and implant options.

  6. Knee arthrodesis using an intramedullary nail.

    PubMed

    Crockarell, John R; Mihalko, Marc J

    2005-09-01

    Fifteen knee arthrodeses using an intramedullary nail were performed in 15 patients. Indications included 11 failed total knee arthroplasties (10 of 11 septic). A retrospective review revealed 100% fusion rate. Complications included 4 cases of painful hardware, 1 trochanteric bursitis, and 1 deep infection. Ten patients were available for assessment at 7 years follow-up. Average leg length discrepancy was 3.7 cm. Anatomic axis averaged 1.3 degrees valgus. Flexion angle averaged 3.5 degrees . Compared with age-matched controls, our patients fared significantly worse in physical functioning, physical role, bodily pain, vitality, and social functioning. Arthrodesis of the knee with an intramedullary nail provides a reliable means of fusion with reasonable alignment. These patients have high rates of pain and diminished functional status.

  7. Congenital yellow nail syndrome: a case report and its relationship to nonimmune fetal hydrops.

    PubMed

    Nanda, Arti; Al-Essa, Fahad H; El-Shafei, Wael M; Alsaleh, Qasem A

    2010-01-01

    Yellow nail syndrome (YNS) is an uncommon disorder characterized by a triad of nail dystrophy, lymphedema, and pleural effusion. It is rare in children and congenital occurrence of YNS has been very rarely described. We report a 2-year-old Arab boy having congenital yellow nail syndrome with mild facial dysmorphism and bilateral conjunctival pigmentation born to consanguineous parents. One of his older siblings had died of nonimmune fetal hydrops (NIFH). The case supports the genetic basis of yellow nail syndrome with a possible relationship to nonimmune fetal hydrops. © 2010 Wiley Periodicals, Inc.

  8. A new mini-invasive technique in treating pediatric diaphyseal forearm fractures by bioabsorbable elastic stable intramedullary nailing: a preliminary technical report.

    PubMed

    Sinikumpu, J-J; Keränen, J; Haltia, A-M; Serlo, W; Merikanto, J

    2013-01-01

    Operative treatment is often indicated in unstable pediatric diaphyseal forearm fractures. Recently minimally invasive reduction and elastic stable intramedullary nailing have been of increasing interest, instead of open reduction and internal fixation with plates. There are several disadvantages of metallic intramedullary implants, such as soft-tissue irritation and a risk of disturbing later imaging. Thus, they are generally removed in later operations. We aimed to develop a new technique to stabilize pediatric forearm fractures by the bioabsorbable intramedullary nailing. We developed a new, two-stage mini-invasive surgical technique to stabilize the unstable diaphyseal fractures in children. The procedure is bioabsorbable elastic stable intramedullary nailing. Ultra-high-strength bioabsorbable intramedullary nails of poly(lactide-co-glycolide) were manufactured for our purpose. The material has been widely proven to be biocompatible and stable enough for fracture treatment as screws and pins. We have used the new technique in the unstable both-bone diaphyseal forearm fractures in children between the ages of 5 and 15 years. We report the technique and our clinical experience in the series of those three cases that have been followed up for at least 12 months. The present series has been randomized for the procedure instead for titanium elastic stable intramedullary nailing, and the series represents a part of ongoing randomized trial. The reported cases operated by the new technique referred good union in the fractured bones and acceptable alignment in the follow-up. Removal of the implants was not required. No troubles with the procedure or implant per se were noticed, indicating good feasibility. One high-energy refracture occurred half year after the primary trauma. Traditional titanium implants were used to control the refracture. We report our preliminary experience of a new surgical mini-invasive procedure to stabilize the unstable pediatric forearm shaft

  9. 76 FR 19124 - Certain Steel Nails From the United Arab Emirates

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-06

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1185 (Preliminary)] Certain Steel Nails From the United Arab Emirates AGENCY: United States International Trade Commission. ACTION: Institution... certain steel nails, provided for in subheadings 7317.00.55, 7317.00.65 and 7317.00.75 of the Harmonized...

  10. 77 FR 27421 - Certain Steel Nails From the United Arab Emirates: Amended Final Determination of Sales at Less...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-10

    ... limited to, nails made of round wire and nails that are cut. Certain steel nails may be of one piece construction or constructed of two or more pieces. Certain steel nails may be produced from any type of steel... following products: Non-collated (i.e., hand-drive or bulk), two-piece steel nails having plastic or steel...

  11. The efficacy of single-stage open intramedullary nailing of neglected femur fractures.

    PubMed

    Boopalan, P R J V C; Sait, Azad; Jepegnanam, Thilak Samuel; Matthai, Thomas; Varghese, Viju Daniel

    2014-02-01

    Neglected femur fractures are not rare in the developing world. Treatment options include single-stage open reduction and intramedullary nailing, or open release, skeletal traction, and then second-stage open intramedullary nailing, with bone grafting. Single-stage procedures have the potential advantage of avoiding neurovascular complications secondary to acute lengthening, but they require a second operation, with potentially increased resource use and infection risk. We sought to determine the (1) likelihood of union, (2) complications and reoperations, and (3) functional results with single-stage open intramedullary nailing without bone grafting in patients with neglected femur fractures. Between January 2003 and December 2007, 17 consecutive patients presented to our practice with neglected femoral shaft fractures. All were treated with single-stage nailing without bone grafting. There were 15 men and two women with a median age of 27 years. The average time from fracture to treatment was 13 weeks (range, 4-44 weeks). Eleven patients underwent open nailing with interlocked nails and six were treated with cloverleaf Kuntscher nails. Patients were followed for a minimum of 6 months (mean, 33 months; range, 6-72 months). The mean preoperative ROM of the knee was 28° (range, 10°-150°) and femoral length discrepancy was 3.1 cm (range, 1-5 cm). All fractures united and the mean time to union was 16 weeks (range, 7-32 weeks). There were no neurologic complications secondary to acute lengthening. The mean postoperative ROM of the knee was 130° (range, 60°-150°). All patients were able to return to preinjury work. Sixteen patients regained their original femoral length. One-stage open intramedullary nailing of neglected femoral diaphyseal fractures without bone grafting was safe and effective, and obviated the need for a two-stage approach. Although the findings need to be replicated in larger numbers of patients, we believe this technique may be useful in

  12. External lead contamination of women's nails by surma in Pakistan: Is the biomarker reliable?

    PubMed

    Ikegami, Akihiko; Takagi, Mai; Fatmi, Zafar; Kobayashi, Yayoi; Ohtsu, Mayumi; Cui, Xiaoyi; Mise, Nathan; Mizuno, Atsuko; Sahito, Ambreen; Khoso, Aneeta; Kayama, Fujio

    2016-11-01

    Adverse health effects of heavy metals are a public health concern, especially lead may cause negative health impacts to human fetal and infantile development. The lead concentrations in Pakistani pregnant women's nails, used as a biomarker, were measured to estimate the lead exposure. Thirteen nail samples out of 84 nails analyzed contained lead higher than the concentration (13.6 μg/g) of the fatal lead poisoning case, raising the possibility of an external contamination. Eye cosmetics such as surma are recognized as one of the important sources of lead exposure in Pakistan. We collected in Pakistan 30 eye cosmetics made in Pakistan, Saudi Arabia and western countries. As the metal composition analysis by energy dispersive X-ray fluorescence spectrometry revealed that some surma samples contained lead more than 96%, the surma might contaminate the nail specimen. Scanning electron microscopy observations showed that lead-containing surma consists of fine particle of galena (ore of lead sulfide) in respirable dust range (less than 10 μm). In addition, relative in vitro bioavailability of lead in the surma was determined as 5.2%. Thus, lead-containing surma consists of inhalable and bioavailable particles, and it contributes an increased risk of lead exposure. Moreover, the relationship between the surma and the lead-contaminated nails by lead isotope ratios analysis indicated the potential of lead contamination in nails by surma. These results suggest that lead in the nails was derived both from body burden of lead and external contamination by lead-containing surma. Therefore, nail is not suited as a biomarker for lead exposure in the countries where surma used, because we may overestimate lead exposure by surface lead contamination in the nail by surma. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Theoretical Modelling of Sound Radiation from Plate

    NASA Astrophysics Data System (ADS)

    Zaman, I.; Rozlan, S. A. M.; Yusoff, A.; Madlan, M. A.; Chan, S. W.

    2017-01-01

    Recently the development of aerospace, automotive and building industries demands the use of lightweight materials such as thin plates. However, the plates can possibly add to significant vibration and sound radiation, which eventually lead to increased noise in the community. So, in this study, the fundamental concept of sound pressure radiated from a simply-supported thin plate (SSP) was analyzed using the derivation of mathematical equations and numerical simulation of ANSYS®. The solution to mathematical equations of sound radiated from a SSP was visualized using MATLAB®. The responses of sound pressure level were measured at far field as well as near field in the frequency range of 0-200 Hz. Result shows that there are four resonance frequencies; 12 Hz, 60 Hz, 106 Hz and 158 Hz were identified which represented by the total number of the peaks in the frequency response function graph. The outcome also indicates that the mathematical derivation correlated well with the simulation model of ANSYS® in which the error found is less than 10%. It can be concluded that the obtained model is reliable and can be applied for further analysis such as to reduce noise emitted from a vibrating thin plate.

  14. Arthrodesis of the knee with an intramedullary nail.

    PubMed

    Donley, B G; Matthews, L S; Kaufer, H

    1991-07-01

    The cases of twenty patients who had an arthrodesis in which an intramedullary nail was used for stabilization were reviewed at an average follow-up of six years. The predominant indications were infection after total knee arthroplasty and post-traumatic pain and instability. Other indications included aseptic loosening of the components of a total knee arthroplasty, reconstruction after resection of a giant-cell tumor, non-union of a fracture of the distal part of the femur or the proximal part of the tibia, and failed external-compression arthrodesis. Success was achieved in seventeen patients (85 per cent), and functional stability immediately postoperatively was gained in all twenty. Of the three patients in whom the arthrodesis failed, all had sustained an intraoperative fracture, and infection eventually developed. Of the twelve nails that were secured to the greater trochanter with a loop of stainless-steel wire, none showed evidence of proximal migration. Of the eight nails that were not thus secured, two migrated proximally, necessitating removal of the nail. Two drawbacks to this operation are the long duration and the large amount of blood that is lost. The major advantage is that a high percentage of patients have progression to a stable fusion despite serious problems. Furthermore, all but seven patients (including the six who had a tumor or who had sustained an intraoperative fracture) were able to bear full weight by the second postoperative week. Only a few patients needed an external support for walking.

  15. Arthrodesis of the knee with intramedullary nail fixation.

    PubMed

    Puranen, J; Kortelainen, P; Jalovaara, P

    1990-03-01

    Thirty-three patients had an arthrodesis of the knee by means of an intramedullary nail introduced through the greater trochanter. Fifteen of the procedures were done for a failed knee arthroplasty; eight had failed because of infection and seven, because of aseptic loosening. Twenty-nine of the thirty-three knees united three to four months after the first attempt at arthrodesis and three united after technical errors were corrected. One knee had a broken nail and a non-union; this was still untreated at the time of writing. Four nails broke: three in the line of fusion and one in the line of an infected supracondylar pseudarthrosis of the femur. No new infections developed after the arthrodesis. Three patients had had an infection and a chronic fistula before the arthrodesis, and the fistulae healed six, fourteen, and eighteen months postoperatively. In another patient, who had had infection and necrosis of the skin preoperatively, the wound healed in six months. All of these knees healed without an additional major operation. The functional result was satisfactory in all patients. After the arthrodesis, seventeen of the thirty-three patients needed less aid when walking, and no patient needed more aid. Fusion of the knee with a long intramedullary nail can be safe and effective, even in the presence of infection, if the revision is performed properly and certain technical principles are followed. It is especially important to establish good contact between the resected bones.

  16. Tibiotalocalcaneal arthrodesis with a curved, interlocking, intramedullary nail.

    PubMed

    Budnar, Vijaya M; Hepple, Steve; Harries, William G; Livingstone, James A; Winson, Ian

    2010-12-01

    Tibiotalocalcaneal fusion with a straight rod has a risk of damaging the lateral plantar neurovascular structures and may interfere with maintaining normal heel valgus position.We report the results of a prospective study of tibiotalocalcaneal (TTC) arthrodesis with a short, anatomically curved interlocking, intramedullary nail. Forty-five arthrodesis in 42 patients, performed between Jan 2003 and Oct 2008, were prospectively followed. The mean followup was 48 (range, 10 to 74) months. The main indications for the procedure were failed ankle arthrodesis with progressive subtalar arthritis, failed ankle arthroplasty and complex hindfoot deformity. The outcome was measured by a combination of pre and postoperative clinical examination, AOFAS hindfoot scores, SF-12 scores and radiological assessment. Union rate was 89% (40/45). Eighty-two percent (37/45) reported improvement in pain and 73% (33/45) had improved foot function. Satisfactory hindfoot alignment was achieved in 84% (38/45). Postoperatively there was a mean improvement in the AOFAS score of 37. Complications included a below knee amputation for persistent deep infection, five nonunions, and three delayed unions. Four nails, six proximal and six distal locking screws were removed for various causes. Other complications included two perioperative fractures, four superficial wound infections and one case of lateral plantar nerve irritation. With a short, anatomically curved intramedullary nail, we had a high rate of tibiotalocalcaneal fusion with minimal plantar neurovascular complications. We believe a short, curved intramedullary nail, with its more lateral entry point, helped maintain hindfoot alignment.

  17. The management of pediatric subtrochanteric femur fractures with a statically locked intramedullary nail.

    PubMed

    Herrera-Soto, José A; Meuret, Robert; Phillips, Jonathan H; Vogel, Daniel J

    2015-01-01

    To evaluate locked intramedullary (IM) fixation as an alternative treatment method for children with subtrochanteric fractures. Retrospective review. Level 1 trauma center in a Children's Hospital. Pediatric patients with subtrochanteric femur fractures with open growth plates. All patients were treated with a lateral entry IM locking nail. Patients were followed until full fracture consolidation or until implant removal. Data on time to full weight bearing, return to full activity, residual pain, any form of gait abnormality, and any other complication from follow-up visits were collected. There were 9 males and 1 female patient with an average age of 12 years and average follow-up of 22 months. Most of the fractures occurred secondary to high-energy trauma. Partial weight bearing was started at 24 days and full at 66 days. Implants were removed on average at 11 months after implantation. There were neither intraoperative complications nor major complications in the postoperative period recorded after removal. Two patients presented with a longer limb on the affected side, both 8 mm, and 2 presented with asymptomatic grade I heterotopic ossification. The use of a statically locked lateral entry IM nail for subtrochanteric femur fractures in children is a safe and efficacious method of treatment with few complications and risks and satisfactory outcomes in children over the age of 8 years. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  18. Nail Damage (Severe Onychodystrophy) Induced by Acrylate Glue: Scanning Electron Microscopy and Energy Dispersive X-Ray Investigations

    PubMed Central

    Pinteala, Tudor; Chiriac, Anca Eduard; Rosca, Irina; Larese Filon, Francesca; Pinteala, Mariana; Chiriac, Anca; Podoleanu, Cristian; Stolnicu, Simona; Coros, Marius Florin; Coroaba, Adina

    2017-01-01

    Background Scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) techniques have been used in various fields of medical research, including different pathologies of the nails; however, no studies have focused on obtaining high-resolution microscopic images and elemental analysis of disorders caused by synthetic nails and acrylic adhesives. Methods Damaged/injured fingernails caused by the use of acrylate glue and synthetic nails were investigated using SEM and EDX methods. Results SEM and EDX proved that synthetic nails, acrylic glue, and nails damaged by contact with acrylate glue have a different morphology and different composition compared to healthy human nails. Conclusions SEM and EDX analysis can give useful information about the aspects of topography (surface sample), morphology (shape and size), hardness or reflectivity, and the elemental composition of nails. PMID:28232921

  19. Osteosynthesis of fractures of the femur with flexible metallic intramedullary nails.

    PubMed

    Firica, A; Troianescu, O; Petre, M

    1978-04-01

    The authors discuss their use of Ender's method in the treatment of fractures of the femur. The diameter and length of the nails depends on the type of fracture. 1) Three nails of 4 mm diameter are introduced in parallel from the medial condyle in fractures of the femoral neck; 2) 5 mm nails are used, in similar fashion, for the fixation of intertrochanteric and subtrochanteric fractures; 3) 5 mm nails are used for diaphyseal, supracondylar and intercondylar fractures, introduced in crossed fashion ("Eiffel Tower" technique) from both medial and lateral condyles. This method of fixation has proved to be extremely stable. The operation itself is quick, with no blood loss or shock. The patient can resume partial weight bearing after a week in stabilised intertrochanteric and shaft fractures, after a month in less stable types, and after three to four months in fractures of the neck of the femur. This report is based on the first 250 cases treated by this method.

  20. [Intramedullary nailing in diaphyseal clavicle fractures using minimally invasive percutaneous reduction].

    PubMed

    Müller, M; Freude, T; Stöckle, U; Kraus, T M

    2017-02-01

    Closed reduction and intramedullary nailing is common in diaphyseal clavicle fractures. The aim of this report is to demonstrate a surgical method with minimally invasive percutaneous reduction in cases where closed reduction fails. The procedure is associated with good cosmetic results. Percutaneous reduction using two reduction forceps enables intramedullary nailing without an open procedure. Open, multifragmented or non-dislocated fractures, oblique fractures due to postoperative dislocation or shortening risk, fracture having potential to become compound fractures, neurovascular complications, pseudoarthroses. The patient is in beach-chair position. After an incision, the nail is entered from medial, two reduction forceps are mounted percutaneously at the lateral and medial fragment. After reduction the nail is pushed forward into the lateral fragment. Thereby, the fracture hematoma is not disturbed for the most part. Early functional rehabilitation with maximal abduction and anteversion of 90° for 6 weeks. Anatomic reduction can be achieved with mild cosmetic impairment.

  1. 3D Optical Investigation of 2 Nail Systems Used in Tibiotalocalcaneal Arthrodesis: A Biomechanical Study.

    PubMed

    Evers, Julia; Lakemeier, Martin; Wähnert, Dirk; Schulze, Martin; Richter, Martinus; Raschke, Michael J; Ochman, Sabine

    2017-05-01

    Although retrograde intramedullary nails for tibiotalocalcaneal arthrodesis (TTCA) are an established fixation method, few studies have evaluated the stability of the available nail systems. The purpose of this study was to compare biomechanically the primary stability of 2 nail-systems, A3 (Small Bone Innovations) and HAN (Synthes), in human cadavers and analyze the exact point of instability in TTCA by means of optical measurement. In 6 pairs of lower legs (n = 12) of fresh-frozen human cadavers with osteoporotic bone structure, bone mineral density (BMD) was determined. Pairwise randomized implantation of either an HAN or A3 nail was executed. Performance and stability were measured by quasi-static tests using 3D motion tracking (NDI Optotrak-Certus) followed by cyclic loading tests during dorsi- and plantarflexion. 3D optical analysis in quasi-static tests showed a significantly lower degree of movement for the HAN nail in rotational and dorsi-/plantarflexion, especially in the subtalar joint. Cyclic loading tests were consistent with quasi-static tests. The A3 nail offered lower stability during axial torsion in the ankle and subtalar joints and during plantar- and dorsiflexion in the subtalar joint in osteoporotic bones. This study was the first to examine the primary stability of different arthrodesis nails in TTCA and their bony parts with a 3D motion analysis. The better stability of the locking-only HAN nail in this osteoporotic test setup could lead to more favorable results in comparison to the A3 nail in clinical use.

  2. Transitioning to an Intramedullary Lengthening and Compression Nail

    PubMed Central

    2017-01-01

    Summary: The magnetic intramedullary lengthening nail is an innovative technology that allows for creative ways to treat difficult problems. The lengthening option has revolutionized femur fracture management with bone loss and malunion therapy. The compression version of this nail has provided a gradual method to compress nonunions and difficult fractures that may obviate the need for many current uses of external fixation. Three cases are presented in this manuscript demonstrating a new paradigm in the management of bone loss/shortening of the tibia and femur, and recalcitrant nonunions. PMID:28486284

  3. A non-asymptotic model of dynamics of honeycomb lattice-type plates

    NASA Astrophysics Data System (ADS)

    Cielecka, Iwona; Jędrysiak, Jarosław

    2006-09-01

    Lightweight structures, consisted of special composite material systems like sandwich plates, are often used in aerospace or naval engineering. In composite sandwich plates, the intermediate core is usually made of cellular structures, e.g. honeycomb micro-frames, reinforcing static and dynamic properties of these plates. Here, a new non-asymptotic continuum model of honeycomb lattice-type plates is shown and applied to the analysis of dynamic problems. The general formulation of the model for periodic lattice-type plates of an arbitrary lay-out was presented by Cielecka and Jędrysiak [Journal of Theoretical and Applied Mechanics 40 (2002) 23-46]. This model, partly based on the tolerance averaging method developed for periodic composite solids by Woźniak and Wierzbicki [Averaging techniques in thermomechanics of composite solids, Wydawnictwo Politechniki Częstochowskiej, Częstochowa, 2000], takes into account the effect of the length microstructure size on the dynamic plate behaviour. The shown method leads to the model equations describing the above effect for honeycomb lattice-type plates. These equations have the form similar to equations for isotropic cases. The dynamic analysis of such plates exemplifies this effect, which is significant and cannot be neglected. The physical correctness of the obtained results is also discussed.

  4. Knee stabilisation following infected knee arthroplasty with bone loss and extensor mechanism impairment using a modular cemented nail.

    PubMed

    Rao, M C; Richards, O; Meyer, C; Jones, R Spencer

    2009-12-01

    Infected Total Knee Replacement with significant bone loss and loss of extensor mechanism poses a difficult management problem. Arthrodesis relying on bony union can be difficult to achieve and can result in significant limb shortening. We retrospectively looked at the outcome of seven patients with significant bone loss and extensor mechanism insufficiency following infected TKR who underwent knee stabilisation using a modular cemented nail. The nail relied on the strong coupling mechanism between the modular femoral and tibial components. Pain score improved from a mean of 7.9 pre-operatively to 1.5 post-operatively at a mean follow up of 39.6 months (range 7-68) months. Two patients underwent technically easy revision nailing for recurrent infection and aseptic loosening. The Endo-Model(R) Knee Fusion Nail (Newsplint, UK/Waldemar Link, GmbH & Co. KG, Hamburg, Germany) has good early results in terms of pain relief and provides a stable knee in cases with significant bone loss and extensor mechanism insufficiency following an infected TKR thus avoiding an above knee amputation.

  5. Quality of life after antegrade intramedullary nail fixation of humeral fractures: a survey in a selected cohort of Brazilian patients.

    PubMed

    Cocco, Luiz Fernando; Ejnisman, Benno; Belangero, Paulo Santoro; Cohen, Moises; Dos Reis, Fernando Baldy

    2018-01-01

    The treatment of humeral fractures remains controversial. Systematic reviews demonstrate similar results between dynamic compression plating and locked intramedullary nailing in the surgical treatment of these fractures. However, it appears that antegrade intramedullary nailing causes higher residual pain in the shoulder. The proposal of this work is to evaluate through the WORC protocol (Western Ontario Rotator Cuff Index) the consequences in the quality of life of patients submitted to osteosynthesis of the humerus with antegrade locked intramedullary nailing. This work is a cohort retrospective study in addition to the application of a questionnaire for self-rated quality of life with its 05 domains (WORC - Western Ontario Rotator Cuff Index) for patients ( N  = 26) classified in the Trauma Sector of the Department of Orthopedics and Traumatology of the Federal University of São Paulo (DOT/UNIFESP) submitted to Humerus Osteosynthesis with Antegrade Locked Intramedullary Nailing. There was also the inclusion of data related to the time since surgery, age, sex, surgical laterality, dominance among members and work leave, which were not considered in the original protocol. After, the data were statistically assessed to evaluate the association between numerical and categorical variables. The overall WORC score was 82.75 ± 17.00 (Mean ± SD) and was not different considering sex, age and postoperative period. Among the WORC domains, both Work and Sport / Recreation Protocols were the most unfavorable factors in the evaluation of patients. Although not statistically significant, those who had the procedure on the dominant side presented a lower quality of life score than those who had the surgery on the non-dominant side. Although non-significant again, those who were away from work had an overall lower quality of life score than those who were not. The WORC Quality of Life Protocol shows good results for evaluating patients submitted to humerus

  6. Evaluation of malrotation following intramedullary nailing in a femoral shaft fracture model: Can a 3D c-arm improve accuracy?

    PubMed

    Ramme, Austin J; Egol, Jonathan; Chang, Gregory; Davidovitch, Roy I; Konda, Sanjit

    2017-07-01

    Difficulty determining anatomic rotation following intramedullary (IM) nailing of the femur continues to be problematic for surgeons. Clinical exam and fluoroscopic imaging of the hip and knee have been used to estimate femoral version, but are inaccurate. We hypothesize that 3D c-arm imaging can be used to accurately measure femoral version following IM nailing of femur fractures to prevent rotational malreduction. A midshaft osteotomy was created in a femur Sawbone to simulate a transverse diaphyseal fracture. An intramedullary (IM) nail was inserted into the Sawbone femur without locking screws or cephalomedullary fixation. A goniometer was used to simulate four femoral version situations after IM nailing: 20° retroversion, 0° version, 15° anteversion, and 30° anteversion. In each simulated position, 3D c-arm imaging and, for comparison purposes, perfect lateral radiographs of the knee and hip were performed. The femoral version of each simulated 3D and fluoroscopic case was measured and the results were tabulated. The measured version from the 3D c-arm images was 22.25° retroversion, 0.66° anteversion, 19.53° anteversion, and 25.15° anteversion for the simulated cases of 20° retroversion, 0° version, 15° anteversion, and 30° anteversion, respectively. The lateral fluoroscopic views were measured to be 9.66° retroversion, 12.12° anteversion, 20.91° anteversion, and 18.77° anteversion for the simulated cases, respectively. This study demonstrates the utility of a novel intraoperative method to evaluate femur rotational malreduction following IM nailing. The use of 3D c-arm imaging to measure femoral version offers accuracy and reproducibility. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Knee fusion--a new technique using an old Belgian surgical approach and a new intramedullary nail.

    PubMed

    Alt, V; Seligson, D

    2001-02-01

    Knee arthrodesis is a useful procedure in difficult cases such as failed total knee arthroplasty, severe articular trauma, bone tumors, and infected knee joints. The most common techniques for knee fusion include external fixation and intramedullary nailing. Küntscher's nail is driven antegrade from the intertrochanteric region into the knee. We describe a new technique for knee arthrodesis using a new intramedullary nail and an old Belgian surgical approach to the knee joint published by Lambotte in 1913. This approach provides excellent exposure for the implantation of the nail by osteotomizing the patella vertically. The nail is implanted using HeyGroves method, whereby the nail is inserted retrograde into the femur and pulled distally anterograde into the tibia. We now use this technique as our standard procedure for knee fusion.

  8. [Residue of organic fluorine pollutants in hair and nails collected from Tianjin].

    PubMed

    Yao, Dan; Zhang, Hong; Chai, Zhi-Fang; Shen, Jin-Can; Yang, Bo; Wang, Yan-Ping; Liu, Guo-Qing

    2013-02-01

    In order to explore the residue and distributions of organic fluorine pollutants in hair and nails, the residue levels of total fluorine (TF), extractable organic fluorine (EOF) and perfluorinated chemicals (PFCs) in hair and nails collected from Tianjin adults were measured by the cyclic neutron activation analysis (CNAA) combined with the high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The results showed that inorganic fluorine (mean: 2.0 mg.kg-1, 4.5 mg.kg-1) was the primary fluorine in TF while EOF(mean: 0.7 mg.kg-1, 1.8 mg.kg-1) was minor. The average amount of identified fluorine (IF) was 0.038 mg.kg-1 in hair and 0.047 mg.kg-1 in nails, accounting or 7.1% (2.6%-16%) and 3.5% (1.1%-11%) of EOF, respectively, which indicated that more than 84% of EOF was unknown. The major residue in hair and nails were medium-and short-chain PFCs,in which perfluorooctane sulfonate, perfluorooctanoic acid and perfluorononanoic acid were the main species. TF, EOF and IF levels in dyed and permed hair were significantly higher than untreated hair (P <0.05), and the concentrations of Sigma PFCs in hair and nails showed no difference between genders. With significantly higher levels of sigma PFCs and PFOS residues than hair (P <0.01), nails could potentially become a more sensitive bioindicator for the exposure level of PFCs in human.

  9. Fragility fractures of the ankle in the elderly: Open reduction and internal fixation versus tibio-talo-calcaneal nailing: Short-term results of a prospective randomized-controlled study.

    PubMed

    Georgiannos, D; Lampridis, V; Bisbinas, I

    2017-02-01

    The management of ankle fractures in the elderly remains unpredictable, secondary to their various co-morbidities. Although tibiotalocalcaneal (TTC) nailing has been an effective option for ankle arthrodesis due to ankle arthritis or Charcot arthropathy there are few reports regarding the use of TTC nail for the treatment of ankle fractures. Aim of this study was to compare the results of ORIF versus TTC nailing for the treatment of unstable ankle fractures in the elderly. We hypothesized that the elderly may benefit from TTC nailing, as it allows the patient to be mobilized immediately after surgery and minimizes the risk of wound or bone problems. This was a prospective, randomized-controlled, comparative study. Between 2009 and 2015, 43 patients were treated with a TTC nail (Group A) and 44 with ORIF (Group B). The Olerud-Molander ankle score was obtained and intraoperative-postoperative complications, length of hospital stay, mobility status and reoperation rate were recorded. The nail fixation was performed with the TrigenR hindfoot nail after closed reduction. ORIF was performed, using a 1/3 tubular plate and 3.5mm screws for the lateral malleolus and two 4.0 mm cannulated screws for the medial. Mortality rate at one year was 13.9% for Group A and 18.1% for Group B. Mean follow-up was 14 months (12-18m). There were no intraoperative complications. Three complications in Group A (8.1%) and twelve (33.3%) in Group B were encountered postoperatively (p<0.05). There was significant shorter hospital stay in Group A (5.2±3.1d) than in Group B (8.4±5.2d). In Group A, 28 patients returned to their pre-injury mobility status (75.6%) while 9 declined one level of the mobility scale (24.3%). In Group B, 26 patients remained at the same mobility level (72.2%) and 10 declined one level (27.7%). There was no significant difference between the postoperative OMAS scores in the two Groups (56.9±9.85 and 56.6±9.3 respectively). We believe that TTC nailing is a safe and

  10. Management of Infection After Intramedullary Nailing of Long Bone Fractures: Treatment Protocols and Outcomes

    PubMed Central

    Makridis, Kostas G; Tosounidis, Theodoros; Giannoudis, Peter V

    2013-01-01

    Implant related sepsis is a relatively unusual complication of intra-medullary nail fixation of long bone fractures. Depending on the extent of infection, timing of diagnosis and progress of fracture union, different treatment strategies have been developed. The aim of this review article is to collect and analyze the existing evidence about the incidence and management of infection following IM nailing of long bone fractures and to recommend treatment algorithms that could be valuable in everyday clinical practice. After searching the P u b M e d /Medline databases, 1270 articles were found related to the topic during the last 20 years. The final review included 28 articles that fulfilled the inclusion criteria. Only a few prospective studies exist to report on the management of infection following IM nailing of long-bone fractures. In general, stage I (early) infections only require antibiotic administration with/without debridement. Stage II (delayed) infections can be successfully treated with debridement, IM reaming, antibiotic nails, and administration of antibiotics. Infected non-unions are best treated with exchange nailing, antibiotic administration and when infection has been eradicated with graft implantation if it is needed. Debridement, exchange nailing and systemic administration of antibiotics is the best indication for stage III (late) infections, while stage III infected non-unions can successfully be treated with nail removal and Ilizarov frame, especially when large bone defects exist. PMID:23919097

  11. Using global, quantitative models of the coupled plates/mantle system to understand Late Miocene dynamics of the Pacific plate

    NASA Astrophysics Data System (ADS)

    Stotz, Ingo; Iaffaldano, Giampiero; Rhodri Davies, D.

    2017-04-01

    Knowledge of the evolution of continents, inferred from a variety of geological data, as well as observations of the ocean-floor magnetization pattern provide an increasingly-detailed picture of past and present-day plate motions. These are key to study the evolving balance of shallow- and deep-rooted forces acting upon plates and to unravel the dynamics of the coupled plates/mantle system. Here we focus on the clockwise rotation of the Pacific plate motion relative to the hotspots reference frame between 10 and 5 Ma, which is evidenced by a bend in the Hawaiian sea mount chain (Cox & Engebretson, 1985) as well as by marine magnetic and bathymetric data along the Pacific/Antarctica Ridge (Croon et al., 2008). It has been suggested that such a kinematic change owes to the arrival of the Ontong-Java plateau, the biggest oceanic plateau on the Pacific plate, at the Australia/Pacific subducting margin between 10 and 5 Ma, and to its collision with the Melanesian arc. This could have changed the local buoyancy forces and/or sparked a redistribution of the forces already acting within the Pacific realm, causing the Pacific plate to rotate clockwise. Such hypotheses have never been tested explicitly against the available kinematic reconstructions. We do so by using global numerical models of the coupled plates/mantle system. Our models build on the available codes Terra and Shells. Terra is a global, spherical finite-element code for mantle convection, developed by Baumgardner (1985) and Bunge et al. (1996), and further advanced by Yang (1997; 2000) and Davies et al. (2013), among others. Shells is a thin-sheet, finite-element code for lithosphere dynamics (e.g., Bird, 1998). By merging these two independent models we are able to simulate the rheological behavior of the brittle lithosphere and viscous mantle. We compare the plate velocities output by our models with the available kinematic reconstructions to test the above-mentioned hypotheses, and simulate the impact of

  12. Numerical modeling of intraplate seismicity with a deformable loading plate

    NASA Astrophysics Data System (ADS)

    So, B. D.; Capitanio, F. A.

    2017-12-01

    We use finite element modeling to investigate on the stress loading-unloading cycles and earthquakes occurrence in the plate interiors, resulting from the interactions of tectonic plates along their boundary. We model a visco-elasto-plastic plate embedding a single or multiple faults, while the tectonic stress is applied along the plate boundary by an external loading visco-elastic plate, reproducing the tectonic setting of two interacting lithospheres. Because the two plates deform viscously, the timescale of stress accumulation and release on the faults is self-consistently determined, from the boundary to the interiors, and seismic recurrence is an emerging feature. This approach overcomes the constraints on recurrence period imposed by stress (stress-drop) and velocity boundary conditions, while here it is unconstrained. We illustrate emerging macroscopic characteristics of this system, showing that the seismic recurrence period τ becomes shorter as Γ and Θ decreases, where Γ = ηI/ηL the viscosity ratio of the viscosities of the internal fault-embedded to external loading plates, respectively, and Θ = σY/σL the stress ratio of the elastic limit of the fault to far-field loading stress. When the system embeds multiple, randomly distributed faults, stress transfer results in recurrence period deviations, however the time-averaged recurrence period of each fault show the same dependence on Γ and Θ, illustrating a characteristic collective behavior. The control of these parameters prevails even when initial pre-stress was randomly assigned in terms of the spatial arrangement and orientation on the internal plate, mimicking local fluctuations. Our study shows the relevance of macroscopic rheological properties of tectonic plates on the earthquake occurrence in plate interiors, as opposed to local factors, proposing a viable model for the seismic behavior of continent interiors in the context of large-scale, long-term deformation of interacting tectonic

  13. Road Nail: Experimental Solar Powered Intelligent Road Marking System

    NASA Astrophysics Data System (ADS)

    Samardžija, Dragan; Teslić, Nikola; Todorović, Branislav M.; Kovač, Erne; Isailović, Đorđe; Miladinović, Bojan

    2012-03-01

    Driving in low visibility conditions (night time, fog or heavy precipitation) is particularly challenging task with an increased probability of traffic accidents and possible injuries. Road Nail is a solar powered intelligent road marking system of wirelessly networked signaling devices that improve driver safety in low visibility conditions along hazardous roadways. Nails or signaling devices are autonomous nodes with capability to accumulate energy, exchange wireless messages, detect approaching vehicles and emit signalization light. We have built an experimental test-bed that consists of 20 nodes and a cellular gateway. Implementation details of the above system, including extensive measurements and performance evaluations in realistic field deployments are presented. A novel distributed network topology discovery scheme is proposed which integrates both sensor and wireless communication aspects, where nodes act autonomously. Finally, integration of the Road Nail system with the cellular network and the Internet is described.

  14. Low-Velocity Nail-Gun Injuries to the Interventricular Septum: Report of Two Cases, One in a Child.

    PubMed

    Michalsen, Kara L; Iguidbashian, John P; Kyser, James P; Long, William B

    2015-08-01

    Nail-gun injury to the heart is rare. Nail-gun injury to the interventricular septum is rarer: we could find only 5 reported cases, and none involving a child. We report 2 additional cases, in which nails penetrated the interventricular septum without causing acute pericardial tamponade, heart block, or shunt across the septum. Transesophageal echocardiography provides a dynamic way to evaluate the patient preoperatively, intraoperatively, and postoperatively. In the cases reported here, both the adult with multiple interventricular nails and the child with a single nail underwent foreign-object removal via median sternotomy. The child needed cardiopulmonary bypass for removal of the nail. There were no short-term or long-term sequelae from these interventricular septal injuries.

  15. Percutaneous osteoplasty with a bone marrow nail for fractures of long bones: experimental study.

    PubMed

    Nakata, Kouhei; Kawai, Nobuyuki; Sato, Morio; Cao, Guang; Sahara, Shinya; Tanihata, Hirohiko; Takasaka, Isao; Minamiguchi, Hiroyuki; Nakai, Tomoki

    2010-09-01

    To develop percutaneous osteoplasty with the use of a bone marrow nail for fixation of long-bone fractures, and to evaluate its feasibility and safety in vivo and in vitro. Six long bones in three healthy swine were used in the in vivo study. Acrylic cement was injected through an 11-gauge bone biopsy needle and a catheter into a covered metallic stent placed within the long bone, creating a bone marrow nail. In the in vitro study, we determined the bending, tug, and compression strengths of the acrylic cement nails 9 cm long and 8 mm in diameter (N = 10). The bending strength of the artificially fractured bones (N = 6) restored with the bone marrow nail and cement augmentation was then compared with that of normal long bones (N = 6). Percutaneous osteoplasty with a bone marrow nail was successfully achieved within 1 hour for all swine. After osteoplasty, all swine regained the ability to run until they were euthanized. Blood tests and pathologic findings showed no adverse effects. The mean bending, tug, and compression strengths of the nail were 91.4 N/mm(2) (range, 75.0-114.1 N/mm(2)), 20.9 N/mm(2) (range, 6.6-30.4 N/mm(2)), and 103.0 N/mm(2) (range, 96.3-110.0 N/mm(2)), respectively. The bending strength ratio of artificially fractured bones restored with bone marrow nail and cement augmentation to normal long bone was 0.32. Percutaneous osteoplasty with use of a bone marrow nail and cement augmentation appears to have potential in treating fractures of non-weight-bearing long bones. Copyright 2010 SIR. Published by Elsevier Inc. All rights reserved.

  16. Interlocking intramedullary nailing in distal tibial fractures.

    PubMed

    Tyllianakis, M; Megas, P; Giannikas, D; Lambiris, E

    2000-08-01

    This retrospective study examined the results of non-pilon fractures of the distal part of the tibia treated with interlocking intramedullary nailing. Seventy-three patients with equal numbers of fractures treated surgically between 1990 and 1998 were reviewed. Mean patient age was 39.8 years, and follow-up averaged 34.2 months. The AO fracture classification system was used. Concomitant fractures of the lateral malleolus were fixed. All but three fractures achieved union within 4.2 months on average. Satisfactory or excellent results were obtained in 86.3% of patients. These results indicate interlocking intramedullary nailing is a reliable method of treatment for these fractures and is characterized by high rates of union and a low incidence of complications.

  17. Primary Retrograde Tibiotalocalcaneal Nailing For Fragility Ankle Fractures.

    PubMed

    Taylor, Benjamin C; Hansen, Dane C; Harrison, Ryan; Lucas, Douglas E; Degenova, Daniel

    2016-01-01

    Ankle fragility fractures are difficult to treat due to poor bone quality and soft tissues as well as the near ubiquitous presence of comorbidities including diabetes mellitus and peripheral neuropathy. Conventional open reduction and internal fixation in this population has been shown to lead to a significant rate of complications. Given the high rate of complications with contemporary fixation methods, the present study aims to critically evaluate the use of acute hindfoot nailing as a percutaneous fixation technique for high-risk ankle fragility fractures. In this study, we retrospectively evaluated 31 patients treated with primary retrograde tibiotalocalcaneal nail without joint preparation for a mean of 13.6 months postoperatively from an urban Level I trauma center during the years 2006-2012. Overall, there were two superficial infections (6.5%) and three deep infections (9.7%) in the series. There were 28 (90.3%) patients that went on to radiographic union at a mean of 22.2 weeks with maintenance of foot and ankle alignment. There were three cases of asymptomatic screw breakage observed at a mean of 18.3 months postoperatively, which were all treated conservatively.. This study shows that retrograde hindfoot nailing is an acceptable treatment option for treatment of ankle fragility fractures. Hindfoot nailing allows early weightbearing, limited soft tissue injury, and a relatively low rate of complications, all of which are advantages to conventional open reduction internal fixation techniques. Given these findings, larger prospective randomized trials comparing this treatment with conventional open reduction internal fixation techniques are warranted.

  18. Primary Retrograde Tibiotalocalcaneal Nailing For Fragility Ankle Fractures

    PubMed Central

    Taylor, Benjamin C.; Hansen, Dane C.; Harrison, Ryan; Lucas, Douglas E; Degenova, Daniel

    2016-01-01

    Background Ankle fragility fractures are difficult to treat due to poor bone quality and soft tissues as well as the near ubiquitous presence of comorbidities including diabetes mellitus and peripheral neuropathy. Conventional open reduction and internal fixation in this population has been shown to lead to a significant rate of complications. Given the high rate of complications with contemporary fixation methods, the present study aims to critically evaluate the use of acute hindfoot nailing as a percutaneous fixation technique for high-risk ankle fragility fractures. Methods In this study, we retrospectively evaluated 31 patients treated with primary retrograde tibiotalocalcaneal nail without joint preparation for a mean of 13.6 months postoperatively from an urban Level I trauma center during the years 2006-2012. Results Overall, there were two superficial infections (6.5%) and three deep infections (9.7%) in the series. There were 28 (90.3%) patients that went on to radiographic union at a mean of 22.2 weeks with maintenance of foot and ankle alignment. There were three cases of asymptomatic screw breakage observed at a mean of 18.3 months postoperatively, which were all treated conservatively.. Conclusions This study shows that retrograde hindfoot nailing is an acceptable treatment option for treatment of ankle fragility fractures. Hindfoot nailing allows early weightbearing, limited soft tissue injury, and a relatively low rate of complications, all of which are advantages to conventional open reduction internal fixation techniques. Given these findings, larger prospective randomized trials comparing this treatment with conventional open reduction internal fixation techniques are warranted. PMID:27528840

  19. An evaluation of flexible intramedullary nail fixation in femoral shaft fractures in paediatric age group.

    PubMed

    Kumar, Sanjay; Roy, Sandip Kumar; Jha, Amrish Kumar; Chatterjee, Debdutta; Banerjee, Debabrata; Garg, Anant Kumar

    2011-06-01

    Sixty-two femoral shaft fractures in 60 patients treated by elastic intramedullary nailing with mean age of the patients being 9.2 years (range 5 years to 12 years) and average follow-up of 15 months (range 7 months to 60 months) are evaluated. Twenty-eight fractures were fixed with titanium elastic nail while 34 fractures were fixed with Enders nail. There were 40 midshaft fractures, 18 proximal femoral and 4 were fractures of distal third. Fracture patterns were transverse in 35, short oblique in 14 cases and 13 were spiral fractures. Mean age of union in this series was 17 weeks (range 12 weeks to 28 weeks). Ten cases had complications, 5 had nail tip irritation, 3 varus or valgus malalignment and 2 had delayed union. In this series, we did not have any non-union, refracture, limb length discrepancy or any major infection. The result demonstrates 100% union rate irrespective of the age, weight and height of the patient. Regardless of the site of fracture and their pattern, it united every time with elastic nail fixation. We did not find and mismatch in the results of fractures stabilised with titanium elastic nail with that of elastic stainless steel nail.

  20. A new global plate velocity model using space geodetic data, REVEL

    NASA Astrophysics Data System (ADS)

    Sella, G. F.; Dixon, T. H.; Mao, A.; Stein, S.

    2001-12-01

    Our model describes the relative velocities of 19 plates and continental blocks, and is derived from publicly available space geodetic (primarily GPS) data for the period 1993-2000. We include an independent and rigorous estimate for GPS velocity uncertainties in order to assess plate rigidity, and propagate these uncertainties to the velocity predictions. By excluding sites that may be influenced by seismic cycle effects within the plate boundary zone as well sites affected by glacial isostatic adjustment, we believe the plate velocity model is representative of geologically Recent motions (last ~10,000 years) and have termed it REVEL, for Recent velocity. Departures from short term rigid plate behaviour due to glacial isostatic adjustment are clearly observed for North America and Eurasia. Australia shows possible differences from rigid plate behavior in a manner consistent with its mapped intraplate stress field. We see statistically significant differences between the velocity predictions of REVEL-2000 and those of the NUVEL-1A geologic model for about one third of tested plate pairs. Pacific-North America motion and motion of the Caribbean plate with respect to North and South America are significantly faster than NUVEL-1A, presumably reflecting systematic errors in the geological model because the relevant rate data do not reflect the full plate rate. Many other differences between the geodetic and geological models appear to reflect real velocity changes over the last few million years. Nubia-Arabia and Arabia-Eurasia appear to be slowing, perhaps related to the collision of Arabia with Eurasia and consequent increased resistance to Arabia's northward motion Several other plate pairs, including Nazca-Pacific, Nazca-South America and Nubia-South America, are experiencing gradual slowing that dates back to about 25 Ma. This is the time of the initiation of the modern Andes mountains, and we speculate that associated crustal thickening on the leading edge of

  1. Focal osteolysis at the junctions of a modular stainless-steel femoral intramedullary nail.

    PubMed

    Jones, D M; Marsh, J L; Nepola, J V; Jacobs, J J; Skipor, A K; Urban, R M; Gilbert, J L; Buckwalter, J A

    2001-04-01

    During routine follow-up of patients treated with a three-piece stainless-steel modular femoral nail, osteolysis and periosteal reaction around the modular junctions of some of the nails were noted on radiographs. The purpose of this study was to evaluate the prevalence, etiology, and clinical relevance of these radiographic findings. Forty-four femoral fractures or nonunions in forty-two patients were treated with a modular stainless-steel femoral intramedullary nail. Seventeen nails were excluded, leaving twenty-seven intramedullary nails in twenty-seven patients for this study. All patients had had a femoral diaphyseal fracture; nineteen had had an acute fracture and eight, a nonunion. These twenty-seven patients returned for radiographs, a physical examination, assessment of functional outcomes, assessment of thigh pain with a visual analog scale, determination of serum chromium levels, and nail removal if desired. A control group of sixteen patients treated with a one-piece stainless-steel femoral intramedullary nail was evaluated with use of the same outcome measures and was compared with the group treated with the modular femoral nail with regard to prevalence of thigh pain and serum chromium levels. Twelve modular femoral nails were removed according to the study protocol. The modular nail junctions were analyzed for corrosion products, and histopathologic analysis of tissue specimens from the femoral canal was performed. The twenty-seven patients were seen at a mean of twenty-one months after fracture fixation; twenty-six of the twenty-seven fractures healed. Twenty-three femora had at least one of three types of abnormalities-osteolysis, periosteal reaction, or cortical thickening--localized to one or both modular junctions. Eighteen patients had severe reactions, defined as osteolysis of > or =2 mm, cortical thickening of > or =5 mm, and/or a periosteal reaction (group 1). Nine patients had mild or no reactions (group 2). Serum chromium levels in group 1

  2. Intramedullary nails with two lag screws.

    PubMed

    Brown, C J; Wang, C J; Yettram, A L; Procter, P

    2004-06-01

    To investigate the structural integrity of intramedullary nails with two lag screws, and to give guidance to orthopaedic surgeons in the choice of appropriate devices. Alternative designs of the construct are considered, and the use of a slotted upper lag screw insertion hole is analysed. Intramedullary fixation devices with a single lag screw have been known to fail at the lag screw insertion hole. Using two lag screws is considered. It has also been proposed to use a slot in the nail for the upper lag screw to prevent the upper lag screw from sticking. Bending and torsion load cases are analysed using finite element method. Consideration of both load conditions is essential. The results present the overall stiffness of the assembly, the load sharing between lag screws, and the possibility for cut-out to occur. While the slot for the upper lag screw might be advantageous with regard to the stresses in the lag screws, it could be detrimental for cut-out occurring adjacent to the lag screws. Comparative analyses demonstrate that two lag screws may be advantageous in patients whose cancellous bone quality is good and who impose large loads on the lag screw/nail interface. However, the use of two screws might pre-dispose to failure by cut-out of the lag screws. The addition of a slotted hole for the upper lag screw appears to do nothing significant to reduce the risk of such a failure. Copyright 2004 Elsevier Ltd.

  3. 76 FR 75871 - Certain Steel Nails From the People's Republic of China: Final Rescission of Antidumping Duty New...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-05

    ... published in the Federal Register our preliminary notice to rescind the NSR with respect to Shanghai Colour... should be rescinded. \\1\\ Shanghai Colour Nail Co., Ltd. (aka, Shanghai Colour Nail Import & Export Co., Ltd.), and Wuxi Colour Nail Co., Ltd. (collectively ``Shanghai Colour''). \\2\\ See Certain Steel Nails...

  4. A preliminary survey of Vietnamese nail salon workers in Alameda County, California.

    PubMed

    Quach, Thu; Nguyen, Kim-Dung; Doan-Billings, Phuong-An; Okahara, Linda; Fan, Cathyn; Reynolds, Peggy

    2008-10-01

    In recent decades, the nail salon industry has been one of the fastest growing in the U.S. California has over 300,000 workers licensed to perform nail care services. Though little is known about their health, these workers routinely handle cosmetic products containing carcinogens and endocrine disruptors that may increase a woman's breast cancer risk. Additionally, an estimated 59-80% of California nail salons are run by Vietnamese women who face socio-cultural barriers that may compromise their workplace safety and health care access. In a pilot project designed to characterize Vietnamese nail salon workers in Alameda County, California in order to inform future health interventions and reduce occupational exposures, we conducted face-to-face surveys with a convenience sample of 201 Vietnamese nail salon workers at 74 salons. Of the workers surveyed, a majority reported that they are concerned about their health from exposure to workplace chemicals. Additionally, a sizeable proportion reported having experienced some health problem after they began working in the industry, particularly acute health problems that may be associated with solvent exposure (e.g. skin and eye irritation, breathing difficulties and headaches). Our findings highlight a critical need for further investigation into the breast cancer risk of nail salon workers, underscored by the workers' routine use of carcinogenic and endocrine-disrupting chemicals, their prevalent health concerns about such chemicals, and their high level of acute health problems. Moreover, the predominance of Vietnamese immigrant women in this workforce makes it an important target group for further research and health interventions.

  5. Nail-fold excision for the treatment of ingrown toenail in children.

    PubMed

    Haricharan, Ramanath N; Masquijo, Javier; Bettolli, Marcos

    2013-02-01

    To evaluate the effectiveness of the nail-fold excision procedure in children. Prospectively collected data on patients less than 18 years of age who underwent a nail-fold excision for symptomatic ingrown toenail were analyzed. Patients were seen in 2 centers and data collected included demographics, site of ingrown toenail, complications (including recurrence), patient satisfaction, and duration of follow-up. Overall, 67 procedures were performed on 50 patients between June 2009 and July 2011 at the 2 institutions. The mean age was 14 years (range, 9-18 years) and 30 were male patients. No recurrences were seen after a follow-up for a median of 14 months (range 6-28 months). Patients were very satisfied with the cosmetic outcomes. Six minor complications occurred, including 3 patients with bleeding requiring dressing change, 2 with excessive granulation tissue, and 1 with nail growth abnormality. The nail-fold excision technique is highly effective in the pediatric population, with no recurrence, excellent cosmesis, and very high patient satisfaction. Copyright © 2013 Mosby, Inc. All rights reserved.

  6. [Advanced bone graft combined with locking compression plate for the treatment of middle and distal tibia nonunion].

    PubMed

    Zhao, Xue; Wang, Pan-feng; Zhang, Yun-tong; Zhang, Chun-cai; Xu, Shuo-gui; Zhang, Xin

    2014-12-01

    To explore methods of treating middle and distal tibia nonunion with the treatment of advanced bone graft combined with locking compression plate. From January 2011 to December 2012, 12 patients with middle and distal tibia nonunion were treated with advanced bone graft combined with locking compression plate. Among patients, there were 8 males and 4 females aged from 20 to 69 with an average of 47 years old. The time from first injuries to bone nonunion was from 9 months to 5 years, avergaed 19 months. Four cases were treated with external fixation, 6 cases were treated with plate fixation, 2 cases of 12 patients occurred broken of plate and nail. Eleven patients were non-infective bone nonunion and 1 patient was infective bone nonunion. Preoperative X-ray and CT showed all patients had sequestration and formation of ossified bone with different degrees. Operative time, blood loss, wound healing were observed, fracture healing time was evaluated by postoperative X-ray. Johner-Wruhs scoring standards was used to evaluate ankle joint function after operation at 10 months. Operative time ranged from 90 to 185 min with an average of (125.00±20.15) min; blood loss ranged from 225 to 750 ml with an average of (415.00±120.00) ml. All patients were followed up from 10 months to 2.5 years with an average of 1.5 years. Postoperative X-ray showed bone union was formed around fracture after operation at 4 months in all patients, 3 cases obtained bone healing within 6 months after operation, 9 cases obtained from 8 to 12 months. No infection, injury of nerve and vessles, and broken of plate and nail were ocurred. According to Johner-Wruhs scoring at 10 months after operation, 10 cases obtained excellent results, 1 good and 1 moderate. Advanced bone graft combined with locking compression plate, which can build fracture multi-point supporting based on full compression of bone nonunion to get effective fixation, is an effective method in treating middle and distal tibia

  7. Models of convection-driven tectonic plates - A comparison of methods and results

    NASA Technical Reports Server (NTRS)

    King, Scott D.; Gable, Carl W.; Weinstein, Stuart A.

    1992-01-01

    Recent numerical studies of convection in the earth's mantle have included various features of plate tectonics. This paper describes three methods of modeling plates: through material properties, through force balance, and through a thin power-law sheet approximation. The results obtained are compared using each method on a series of simple calculations. From these results, scaling relations between the different parameterizations are developed. While each method produces different degrees of deformation within the surface plate, the surface heat flux and average plate velocity agree to within a few percent. The main results are not dependent upon the plate modeling method and herefore are representative of the physical system modeled.

  8. Additional Tension Screws Improve Stability in Elastic Stable Intramedullary Nailing: Biomechanical Analysis of a Femur Spiral Fracture Model.

    PubMed

    Zachert, Gregor; Rapp, Marion; Eggert, Rebecca; Schulze-Hessing, Maaike; Gros, Nina; Stratmann, Christina; Wendlandt, Robert; Kaiser, Martin M

    2015-08-01

    For pediatric femoral shaft fractures, elastic stable intramedullary nailing (ESIN) is an accepted method of treatment. But problems regarding stability with shortening or axial deviation are well known in complex fracture types and heavier children. Biomechanical in vitro testing was performed to determine whether two modified osteosyntheses with an additional tension screw fixation or screw fixation alone without nails could significantly improve the stability in comparison to classical ESIN. A total of 24 synthetic adolescent-sized femoral bone models (Sawbones, 4th generation; Vashon, Washington, United States) with an identical spiral fracture (length 100 mm) were used. All grafts underwent retrograde fixation with two C-shaped steel nails (2C). Of the 24, 8 osteosyntheses were supported by one additional tension screw (2C1S) and another 8 by two screws (2S) in which the intramedullary nails were removed before testing. Each configuration underwent biomechanical testing in 4-point bending, external rotation (ER) and internal rotation (IR). Furthermore, the modifications were tested in axial physiological 9 degrees position for shifting and dynamic compression as well as dynamic load. Both screw configurations (2C1S and 2S) demonstrated a significantly higher stability in comparison to the 2C configuration in 4-point bending (anterior-posterior, 0.95 Nm/mm [2C] < 8.41 Nm/mm [2C1S] and 15.12 Nm/mm [2S]; posterior-anterior, 8.55 Nm/mm [2C] < 12.65 Nm/mm [2C1S] and 17.54 Nm/mm [2S]; latero-medial, 1.17 Nm/mm [2C] < 5.53 Nm/mm [2C1S] and 9.15 Nm/mm [2S]; medio-lateral, 1.74 Nm/mm [2C] < 9.69 Nm/mm [2C1S] and 12.20 Nm [2S]; all p < 0.001) and during torsion (ER, 0.61 Nm/degree [2C] < 4.10 Nm/degree [2C1S] and 9.29 Nm/degree [2S]; IR, 0.18 Nm/degree [2C] < 6.17 Nm/degree [2C1S] and 10.61 Nm/degree [2S]; all p < 0.001]. The shifting in compression in 9 degrees position was only slightly influenced. The comparison of 2S versus 2C1S showed more stability for

  9. [Tibio-talo-calcaneal arthrodesis by retrograde intramedullary nail--a case report].

    PubMed

    Lipiński, Łukasz; Synder, Marek; Sibiński, Marcin

    2011-01-01

    We described a case of 64 year old overweight women, who was treated with revision tibio-talo-calcaneal artrodesis with the use of retrograde intramedullary nail. The procedure was performed after failed primary arthrodesis with the use of lateral approach and fibula osteotomy. Stabilization with intramedullary nail gave good clinical and functional result with a good bone healing.

  10. Nail-biting stuff? The effect of N-acetyl cysteine on nail-biting.

    PubMed

    Berk, Michael; Jeavons, Sue; Dean, Olivia M; Dodd, Seetal; Moss, Kirsteen; Gama, Clarissa S; Malhi, Gin S

    2009-07-01

    N-acetyl cysteine (NAC) is a widely available nutraceutical with a variety of actions. As a precursor of cysteine and glutathione, it has antioxidant properties that may impact on mood and contribute to an effect on impulsivity and obsessive behaviour. Via its additional effect on glutamate via the cystine-glutamate exchange system, NAC has been shown to mediate impulsivity in preclinical models of addiction, reduce craving, and cue extinction. Further, by boosting glutathione, NAC acts as a potent antioxidant and has been shown in two positive, large-scale randomized placebo-controlled trials to affect negative symptoms in schizophrenia and depression in bipolar disorder. We describe three cases in which its actions specifically on nail-biting and associated anxiety may offer a potential treatment. The spontaneous findings are reported as part of an ongoing treatment trial examining the utility of NAC in bipolar disorder. Its actions, if robustly replicated, also point to potential treatment targets in glutathione or glutamate pathways in the brain.

  11. Side Effects: Skin and Nail Changes

    Cancer.gov

    Cancer treatments can cause skin to become dry, itchy, red, or peel. Nails may become dark, yellow, or cracked. Learn about signs of skin problems that may need urgent medical care. Get a helpful list of questions to ask your doctor.

  12. Using Global, Quantitative Models of the Coupled Plates/Mantle System to Understand Late Neogene Dynamics of the Pacific Plate

    NASA Astrophysics Data System (ADS)

    Stotz, I.; Davies, R.; Iaffaldano, G.

    2016-12-01

    Knowledge of the evolution of continents, inferred from a variety of geological data, as well as observations of the ocean-floor magnetization pattern provide an increasingly-detailed picture of past and present-day plate motions. These are key to study the evolving balance of shallow- and deep-rooted forces acting upon plates and to unravel the dynamics of the coupled plates/mantle system. Here we focus on the clockwise rotation of the Pacific plate motion relative to the hotspots reference frame between 10 and 5 Ma, which is evidenced by a bend in the Hawaiian sea mount chain (Cox & Engebretson, 1985) as well as by marine magnetic and bathymetric data along the Pacific/Antarctica Ridge (Croon et al., 2008). It has been suggested that such a kinematic change owes to the arrival of the Ontong-Java plateau, the biggest oceanic plateau on the Pacific plate, at the Australia/Pacific subducting margin between 10 and 5 Ma, and to its collision with the Melanesian arc. This could have changed the local buoyancy forces and/or sparked a redistribution of the forces already acting within the Pacific realm, causing the Pacific plate to rotate clockwise. Such hypotheses have never been tested explicitly against the available kinematic reconstructions. We do so by using global numerical models of the coupled plates/mantle system. Our models build on the available codes Terra and Shells. Terra is a global, spherical finite-element code for mantle convection, developed by Baumgardner (1985) and Bunge et al. (1996), and further advanced by Yang (1997; 2000) and Davies et al. (2013), among others. Shells is a thin-sheet, finite-element code for lithosphere dynamics (e.g., Bird, 1998). By merging these two independent models we are able to simulate the rheological behavior of the brittle lithosphere and viscous mantle. We compare the plate velocities output by our models with the available kinematic reconstructions to test the above-mentioned hypotheses, and simulate the impact of

  13. Treatment of the femoral shaft fracture with a curved heat-treated COP clover-leaf nail.

    PubMed

    Onoue, Y; Sunami, Y; Fujiwara, H; Sadakane, T; Yasuda, S

    1979-01-01

    The commonly used straight intramedullary nail has certain limitations and disadvantages. Following radiographic and metallurgical studies we have developed a curved heat-treated clover-leaf nail using a newly developed precipitation hardening stainless steel (COP). The nail is bent with a slot on the convex side and the radius of curvature is 115 cm which corresponds to the anatomical antero-lateral convexity of the human femur. The nail has been satisfactory in clinical use since 1971 and has provided not only more stable internal fixation but also allowed fixation of fractures beyond the middle third of the shaft.

  14. A Review of Indigo Naturalis as an Alternative Treatment for Nail Psoriasis.

    PubMed

    McDermott, Laura; Madan, Raman; Rupani, Reena; Siegel, Daniel

    2016-03-01

    Nail psoriasis is challenging to treat. The few currently available therapies are limited in efficacy, and often produce unfavorable side effects. A plant extract widely used in Traditional Chinese Medicine, indigo naturalis (Qing Dai), is presented in this review as an alternative topical treatment for skin and nail psoriasis. The purpose of this article is to present information on a viable alternative treatment with a favorable side effect profile for a difficult disease to treat. A PubMed search for the term "indigo naturalis" was performed, and literature from 2006 to the present relevant to indigo naturalis and treatment of psoriasis and nail psoriasis was reviewed. Indigo naturalis shares several therapeutic mechanisms with current psoriasis treatments, such as regulation of keratinocyte proliferation and differentiation, restoration of epidermal barrier function, and reduction of inflammatory processes. Clinically, it is well tolerated. Recent research of indigo naturalis suggests that it is a safe, inexpensive, and effective alternative topical treatment for skin and nail psoriasis.

  15. The effects of nail rigidity on fracture healing in rats with osteoporosis

    PubMed Central

    Sha, Mo; Fu, Jun; Li, Jing; Fan Yuan, Chao; Shi, Lei; Jun Li, Shu

    2009-01-01

    Background and purpose Stress shielding from rigid internal fixation may lead to refracture after removal of the osteosynthesis material. We investigated the effect of a low-rigidity (Ti-24Nb-4Zr-7.9Sn) intramedullary nail regarding stress shielding and bone healing of osteoporotic fractures in the rat. Methods 40 female Sprague-Dawley rats, aged 3 months, were divided into the following groups: sham-operation (SHAM) (n = 10), ovariectomized (OVX) (n = 10) and OVX-fracture (n = 20). 10 SHAM rats and 10 OVX rats were killed after 12 weeks to provide biomechanical data. Ovariectomy was performed 12 weeks before fracturing both femurs in 20 rats. The left fracture was stabilized with a high-rigidity titanium alloy pin (Ti-6Al-4V; elastic modulus 110 GPa) and the right with a low-rigidity (Ti-24Nb-4Zr-7.9Sn; elastic modulus 33 GPa). The bony calluses were examined by micro-CT at 6 and 12 weeks after fracture, bone volume (BV) and total volume (TV) were determined at the callus region (ROI1) and the total femur (ROI2). Subsequently, the bones were tested mechanically by a three-point bending test. Results In the low-rigidity group, TV (ROI1) increased at 6 weeks, but BV (ROI1), BV (ROI2) were similar but maximum load increased. At 12 weeks, the maximum load and also BV (ROI1, ROI2) were increased in the low-rigidity group. Interpretation The low-rigidity nail manufactured from Ti-24Nb-4Zr-7.9Sn showed better external callus formation, seemed to reduce effects of stress shielding, and reduced bone resorption better than the stiffer nail. The low-rigidity nail was strong enough to maintain alignment of the fracture in the osteoporotic rat model without delayed union. PMID:19297794

  16. Penetrating brain injury caused by nail guns: two case reports and a review of the literature.

    PubMed

    Luo, Wei; Liu, Hai; Hao, Shuyu; Zhang, Ying; Li, Jingsheng; Liu, Baiyun

    2012-01-01

    To the best of the authors' knowledge, there are few case reports of penetrating brain injuries (PBI) caused by nail guns and these have usually involved incomplete penetration of the skull. Complete penetration of a nail into the intracranial cavity is extremely rare. Here, two such cases are presented. In the first, the nail entered through the right temporal bone, lodged in the right temporal lobe and was removed via craniotomy with intra-operative ultrasound guidance. In the second, the nail destroyed the left parietal bone, damaged the left internal capsule and lodged in the left temporal lobe near the left petrous apex and the brain stem. According to the latest literature retrieval, this is the first reported case of nail-gun injury to the internal capsule. The position of the nail precluded removal without further neurologic damage. Treatment strategies designed to optimize outcome, with or without surgery, and possible complications are discussed in this report.

  17. Tibial lengthening over intramedullary nails

    PubMed Central

    Burghardt, R. D.; Manzotti, A.; Bhave, A.; Paley, D.

    2016-01-01

    Objectives The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method. Methods In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group. Results The mean external fixation time for the LON group was 2.6 months and for the matched case group was 7.6 months. The mean lengthening amounts for the LON and the matched case groups were 5.2 cm and 4.9 cm, respectively. The radiographic consolidation time in the LON group was 6.6 months and in the matched case group 7.6 months. Using a clinical and radiographic outcome score that was designed for this study, the outcome was determined to be excellent in 17 and good in two patients for the LON group. The outcome was excellent in 14 and good in five patients in the matched case group. The LON group had increased blood loss and increased cost. The LON group had four deep infections; the matched case group did not have any deep infections. Conclusions The outcomes in the LON group were comparable with the outcomes in the matched case group. The LON group had a shorter external fixation time but experienced increased blood loss, increased cost, and four cases of deep infection. The advantage of reducing external fixation treatment time may outweigh these disadvantages in patients who have a healthy soft-tissue envelope. Cite this article: J. E. Herzenberg. Tibial lengthening over intramedullary nails: A matched case comparison with Ilizarov tibial lengthening. Bone Joint Res 2016;5:1–10. doi: 10.1302/2046-3758.51.2000577 PMID:26764351

  18. Splitting of the Proximal Femur With a New Femoral Nail

    DTIC Science & Technology

    2010-04-01

    should be exercised with the use of new implants that require a change in customary technique. In addition, some concern must be raised by the amount of...the potential for gluteus medius tendon injury,8 whereas other authors have found greater soft-tissue injury by inserting a nail through the...Entry Femoral Nail (Synthes USA, Paoli, PA) moved the entry point further lateral (10 degrees) and distal to completely avoid the gluteus medius tendon

  19. Allergic contact dermatitis from sculptured acrylic nails: special presentation with an airborne pattern

    PubMed Central

    Maio, Paula; Carvalho, Rodrigo; Amaro, Cristina; Santos, Raquel; Cardoso, Jorge

    2012-01-01

    Methylmethacrylate was first reported in 1941 as a cause of contact dermatitis. Since then, occupational contact allergies to acrylates in dentistry, orthopedic surgery, printing industry and industry have been reported, but few reports are found in the literature as a consequence of the contact with sculptured artificial acrylic nails which are increasingly popular. We describe here 3 patients with contact allergy to acrylates in artificial sculptured nails. Patch tests were performed with the Portuguese baseline series of contact allergens and an extended series of acrylates were applied. In particular, we tested three female patients with allergic contact dermatitis from sculptured acrylic nails. Two of these patients were both customers and also technical nail beauticians. Two patients developed periungual eczema; one presented only with face and eyelid dermatitis had no other lesions. The tests showed positive reaction to 2-hydroxyethylmethacrylate (2-HEMA) and 2-hydroxypropylmethacrylate (2-HPMA) in all the three patients. Our cases demonstrate the variety of clinical presentations of allergic contact dermatitis from acrylic sculptured nails. They show the need to warn patients of persistent and sometimes permanent side effects of these products. They also emphasize the importance of cosmetic ingredient labeling. PMID:25386316

  20. The effect of different torque wrenches on rotational stiffness in compressive femoral nails: a biomechanical study.

    PubMed

    Karaarslan, A A; Acar, N

    2018-02-01

    Rotation instability and locking screws failure are common problems. We aimed to determine optimal torque wrench offering maximum rotational stiffness without locking screw failure. We used 10 conventional compression nails, 10 novel compression nails and 10 interlocking nails with 30 composite femurs. We examined rotation stiffness and fracture site compression value by load cell with 3, 6 and 8 Nm torque wrenches using torsion apparatus with a maximum torque moment of 5 Nm in both directions. Rotational stiffness of composite femur-nail constructs was calculated. Rotational stiffness of composite femur-compression nail constructs compressed by 6 Nm torque wrench was 3.27 ± 1.81 Nm/angle (fracture site compression: 1588 N) and 60% more than that compressed with 3 Nm torque wrench (advised previously) with 2.04 ± 0.81 Nm/angle (inter fragmentary compression: 818 N) (P = 0.000). Rotational stiffness of composite-femur-compression nail constructs compressed by 3 Nm torque wrench was 2.04 ± 0.81 Nm/angle (fracture site compression: 818 N) and 277% more than that of interlocking nail with 0.54 ± 0.08 Nm/angle (fracture site compression: 0 N) (P = 0.000). Rotational stiffness and fracture site compression value produced by 3 Nm torque wrench was not satisfactory. To obtain maximum rotational stiffness and fracture site compression value without locking screw failure, 6 Nm torque wrench in compression nails and 8 Nm torque wrench in novel compression nails should be used.

  1. Role of the fibula in the stability of diaphyseal tibial fractures fixed by intramedullary nailing.

    PubMed

    Galbraith, John G; Daly, Charles J; Harty, James A; Dailey, Hannah L

    2016-10-01

    For tibial fractures, the decision to fix a concomitant fibular fracture is undertaken on a case-by-case basis. To aid in this clinical decision-making process, we investigated whether loss of integrity of the fibula significantly destabilises midshaft tibial fractures, whether fixation of the fibula restores stability to the tibia, and whether removal of the fibula and interosseous membrane for expediency in biomechanical testing significantly influences tibial interfragmentary mechanics. Tibia/fibula pairs were harvested from six cadaveric donors with the interosseous membrane intact. A tibial osteotomy fracture was fixed by reamed intramedullary (IM) nailing. Axial, torsion, bending, and shear tests were completed for four models of fibular involvement: intact fibula, osteotomy fracture, fibular plating, and resected fibula and interosseous membrane. Overall construct stiffness decreased slightly with fibular osteotomy compared to intact bone, but this change was not statistically significant. Under low loads, the influence of the fibula on construct stability was only statistically significant in torsion (large effect size). Fibular plating stiffened the construct slightly, but this change was not statistically significant compared to the fibular osteotomy case. Complete resection of the fibula and interosseous membrane significantly decreased construct torsional stiffness only (large effect size). These results suggest that fixation of the fibula may not contribute significantly to the stability of diaphyseal tibial fractures and should not be undertaken unless otherwise clinically indicated. For testing purposes, load-sharing through the interosseous membrane contributes significantly to overall construct mechanics, especially in torsion, and we recommend preservation of these structures when possible. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. A true polar wander model for Neoproterozoic plate motions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ripperdan, R.L.

    1992-01-01

    Recent paleogeographic reconstructions for the interval 750--500 Ma (Neoproterozoic to Late Cambrian) require rapid rates of plate motion and/or rotation around an equatorial Euler pole to accommodate reconstructions for the Early Paleozoic. Motions of this magnitude appear to be very uncommon during the Phanerozoic. A model for plate motions based on the hypothesis that discrete intervals of rapid true polar wander (RTPW) occurred during the Neoproterozoic can account for the paleogeographic changes with minimum amounts of plate motion. The model uses the paleogeographic reconstructions of Hoffman (1991). The following constraints were applied during derivation of the model: (1) relative motionsmore » between major continental units were restricted to be combinations of great circle or small circle translations with Euler poles of rotation = spin axis; (2) maximum rates of relative translational plate motion were 0.2 m/yr. Based on these constraints, two separate sets of synthetic plate motion trajectories were determined. The sequence of events in both can be summarized as: (1) A rapid true polar wander event of ca 90[degree] rafting a supercontinent to the spin axis; (2) breakup of the polar supercontinent into two fragments, one with the Congo, West Africa, Amazonia, and Baltica cratons, the other with the Laurentia, East Gondwana, and Kalahari cratons; (3) great circle motion of the blocks towards the equator; (4) small circle motion leading to amalgamation of Gondwana and separation of Laurentia and Baltica. In alternative 1, rifting initiates between East Antarctica and Laurentia and one episode of RTPW is required. Alternative 2 requires two episodes of RTPW; and that rifting occurred first along the eastern margin and later along the western margin of Laurentia. Synthetic plate motion trajectories are compared to existing paleomagnetic and geological data, and implications of the model for paleoclimatic changes during the Neoproterozoic are discussed.« less

  3. Unusual penetration of a construction nail through the orbit to the cranium: a case report.

    PubMed

    Erkutlu, Ibrahim; Alptekin, Mehmet; Dokur, Mehmet; Geyik, Murat; Gök, Abdulvahap

    2011-01-01

    Penetrating head and neck trauma with construction nails are uncommon life-threatening injuries and an important problem in developing countries. Assessment of the neurovascular and systemic physical status is a first requirement, and the decision concerning which surgical approach to perform for the removal of the nail is of critical importance. A 10-year-old girl was presented one hour after a fall injury with complaint of a swelling and foreign body lodgment on the left forehead. Neurological and systemic physical examinations were normal except for weak direct pupillary light reflex on the left side and the patient's state of uneasiness. Radiological investigations showed that the head of the nail had entered from the left infra-orbital region and become lodged through the orbital roof, below the frontal bone. Surgical extraction of the nail in the operating room was performed successfully using left pterional craniotomy and lateral orbitotomy technique, and there was no complication after surgery. Here, we report a case with a rare craniocerebral penetrating wound and type, with the head of the nail lodged in the anterior fossa through the orbital roof, which may be defined as 'reverse penetration of the nail'.

  4. Is there a role for intramedullary nails in the treatment of simple pilon fractures? Rationale and preliminary results.

    PubMed

    Marcus, Matthew S; Yoon, Richard S; Langford, Joshua; Kubiak, Erik N; Morris, Andrew J; Koval, Kenneth J; Haidukewych, George J; Liporace, Frank A

    2013-08-01

    Certain patients with pilon fractures present with significant soft-tissue swelling or with a poor soft-tissue envelope typically not amenable to definitive fixation in the early time period. The objective of this study was to review the treatment of simple intra-articular fractures of the tibial plafond (Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) type 43C1-C2) via intramedullary nailing (IMN) with the assessment of clinical and radiographic results and any associated complications. Retrospective clinical and radiological reviews of 31 patients sustaining AO/OTA type 43C distal tibial fractures treated with IMN were evaluated. Our main outcome measurement included achievable alignment in the immediate postoperative period and at the time of union along with complications or need for secondary procedures within the first year of follow-up. Seven patients were lost to follow-up. All the remaining patients achieved bony union at a mean union time of 14.1 ± 4.9 weeks with no evidence of malunion or malrotation. All patients were at full-weight-bearing status at 1-year follow-up. Complications were notable for one delayed union, one non-union, one patient with superficial wound drainage, two with deep infection, one with symptomatic hardware and one with deep vein thrombosis. Simple articular fractures of the tibial plafond (AO/OTA type 43C) treated via IMN can achieve excellent alignment and union rates with proper patient selection and surgical indication. One should not hesitate to use additional bone screws or plating options to help achieve better anatomic reduction. However, larger, prospective randomised trials comparing plating versus nailing, in experienced hands, are needed to completely delineate the utility of this treatment modality. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Soil nailing of a bridge embankment : report 2 : design and field performance report.

    DOT National Transportation Integrated Search

    1995-07-01

    Soil nailing has recently been introduced in Oregon as an alternative lateral earth support method. The first permanent soil nail wall on the state's highway system was used where an underpass was widened under the existing Oregon Slough Bridge in Po...

  6. 76 FR 16379 - Certain Steel Nails From the People's Republic of China: Final Results of the First Antidumping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-23

    ...) Maanshan Longer Nail Product Co., Ltd. (24) Nanjing Dayu Pneumatic Gun Nails Co., Ltd. (25) Qingdao.... (71) Tianjin Shishun Metallic Products Co., Ltd. (72) Tianjin Xiantong Fucheng Gun Nail Manufacture Co...

  7. Assessing indoor air quality in New York City nail salons.

    PubMed

    Pavilonis, Brian; Roelofs, Cora; Blair, Carly

    2018-05-01

    Nail salons are an important business and employment sector for recent immigrants offering popular services to a diverse range of customers across the United States. However, due to the nature of nail products and services, salon air can be burdened with a mix of low levels of hazardous airborne contaminants. Surveys of nail technicians have commonly found increased work-related symptoms, such as headaches and respiratory irritation, that are consistent with indoor air quality problems. In an effort to improve indoor air quality in nail salons, the state of New York recently promulgated regulations to require increased outdoor air and "source capture" of contaminants. Existing indoor air quality in New York State salons is unknown. In advance of the full implementation of the rules by 2021, we sought to establish reliable and usable baseline indoor air quality metrics to determine the feasibility and effectiveness of the requirement. In this pilot study, we measured total volatile organic compounds (TVOC) and carbon dioxide (CO 2 ) concentrations in 10 nail salons located in New York City to assess temporal and spatial trends. Within salon contaminant variation was generally minimal, indicating a well-mixed room and similar general exposure despite the task being performed. TVOC and CO 2 concentrations were strongly positively correlated (ρ = 0.81; p < 0.01) suggesting that CO 2 measurements could potentially be used to provide an initial determination of acceptable indoor air quality for the purposes of compliance with the standard. An almost tenfold increase in TVOC concentration was observed when the American National Standards Institute/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ANSI/ASHRAE) target CO 2 concentration of 850 ppm was exceeded compared to when this target was met.

  8. A non-classical Mindlin plate model incorporating microstructure, surface energy and foundation effects.

    PubMed

    Gao, X-L; Zhang, G Y

    2016-07-01

    A non-classical model for a Mindlin plate resting on an elastic foundation is developed in a general form using a modified couple stress theory, a surface elasticity theory and a two-parameter Winkler-Pasternak foundation model. It includes all five kinematic variables possible for a Mindlin plate. The equations of motion and the complete boundary conditions are obtained simultaneously through a variational formulation based on Hamilton's principle, and the microstructure, surface energy and foundation effects are treated in a unified manner. The newly developed model contains one material length-scale parameter to describe the microstructure effect, three surface elastic constants to account for the surface energy effect, and two foundation parameters to capture the foundation effect. The current non-classical plate model reduces to its classical elasticity-based counterpart when the microstructure, surface energy and foundation effects are all suppressed. In addition, the new model includes the Mindlin plate models considering the microstructure dependence or the surface energy effect or the foundation influence alone as special cases, recovers the Kirchhoff plate model incorporating the microstructure, surface energy and foundation effects, and degenerates to the Timoshenko beam model including the microstructure effect. To illustrate the new Mindlin plate model, the static bending and free vibration problems of a simply supported rectangular plate are analytically solved by directly applying the general formulae derived.

  9. A non-classical Mindlin plate model incorporating microstructure, surface energy and foundation effects

    PubMed Central

    Zhang, G. Y.

    2016-01-01

    A non-classical model for a Mindlin plate resting on an elastic foundation is developed in a general form using a modified couple stress theory, a surface elasticity theory and a two-parameter Winkler–Pasternak foundation model. It includes all five kinematic variables possible for a Mindlin plate. The equations of motion and the complete boundary conditions are obtained simultaneously through a variational formulation based on Hamilton's principle, and the microstructure, surface energy and foundation effects are treated in a unified manner. The newly developed model contains one material length-scale parameter to describe the microstructure effect, three surface elastic constants to account for the surface energy effect, and two foundation parameters to capture the foundation effect. The current non-classical plate model reduces to its classical elasticity-based counterpart when the microstructure, surface energy and foundation effects are all suppressed. In addition, the new model includes the Mindlin plate models considering the microstructure dependence or the surface energy effect or the foundation influence alone as special cases, recovers the Kirchhoff plate model incorporating the microstructure, surface energy and foundation effects, and degenerates to the Timoshenko beam model including the microstructure effect. To illustrate the new Mindlin plate model, the static bending and free vibration problems of a simply supported rectangular plate are analytically solved by directly applying the general formulae derived. PMID:27493578

  10. 76 FR 22369 - Certain Steel Nails From the People's Republic of China: Initiation and Preliminary Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-21

    ... Review AGENCY: Import Administration, International Trade Administration, Department of Commerce. DATES... review and a request to revoke, in part, the antidumping duty order on certain steel nails from the... nails. In addition to the four physical descriptions of steel nails, Petitioner requested three of the...

  11. Dynamic Stiffness Modeling of Composite Plate and Shell Assemblies

    DTIC Science & Technology

    2013-12-09

    FA8655-10-1-3084 Report 6 Dynamic Stiffness Modelling of Plate and Shell Assemblies 4 Introduction Aerospace structures are generally made up of thin ...Sound and Vibration, 294(1- 2):131–161, 2006. [23] Y. F. Xing and B. Liu. New exact solutions for free vibrations of thin orthotropic rectangular plates ...Structures, 89(5–6):467–475, 2011. [80] A.Y.T. Leung. Dynamic stiffness analysis of laminated composite plates . Thin - Walled Structures, 25:109–133, 1996

  12. Rotary self-locking intramedullary nail for long tubular bone fractures.

    PubMed

    Huang, Zhong-lian; Yang, Hai-long; Xu, Jian-kun; Xia, Xue; Wang, Xin-jia; Song, Jian-xin; Hu, Jun

    2013-10-01

    Intramedullary nails had been widely used in the treatment of long-bone fractures because of less interference of fractures and center bearing biomechanical advantage. However, it had been also found many shortcomings such as broken nails, delayed healing and was modified in order to achieve better efficacy and reduce complications. The aim of the present study is to compare the efficacy of rotary self-locking intramedullary nails (RSIN) with that of interlocking intramedullary nails (IIN) in the treatment of long-bone fractures. A retrospective study investigated 129 cases with long-bone fractures (36 with femoral fracture, 81 with tibial fracture, and 12 with humeral fracture). The fractures were fixed using either an RSIN or IIN. All patients underwent followup for 12-30 months. All patients in both groups achieved a clinical fracture healing standard and the postoperative affected limb muscle strength and joint function were well restored. The RSIN group required a shorter operative time and the fracture healed faster. There was no significant difference in the hospital stay, intraoperative blood loss or postoperative complications between the two groups. RSIN is used to treat long-bone fractures. Its healing efficacy is equivalent to the IIN. Moreover, the RSIN method is simpler and causes less tissue damage than the IIN, therefore having the advantage of accelerated healing.

  13. A clinical trial to investigate the effect of Cynatine HNS on hair and nail parameters.

    PubMed

    Beer, Christina; Wood, Simon; Veghte, Robert H

    2014-01-01

    A new, novel product, Cynatine HNS, was evaluated for its effects as a supplement for improving various aspects of hair and nails in a randomized, double-blind, placebo-controlled clinical trial. A total of 50 females were included and randomized into two groups. The active group (n = 25) received 2 capsules containing Cynatine HNS, comprised of Cynatine brand keratin (500 mg) plus vitamins and minerals, per day, and the placebo group (n = 25) received 2 identical capsules of maltodextrin per day for 90 days. End points for hair loss, hair growth, hair strength, amino acid composition, and hair luster were measured. End points were also measured for nail strength and the appearance of nails. The results show that subjects taking Cynatine HNS showed statistically significant improvements in their hair and nails when compared to placebo. Cynatine HNS is an effective supplement for improving hair and nails in 90 days or less. EudraCT number is 2014-002645-22.

  14. A Clinical Trial to Investigate the Effect of Cynatine HNS on Hair and Nail Parameters

    PubMed Central

    Veghte, Robert H.

    2014-01-01

    Objective. A new, novel product, Cynatine HNS, was evaluated for its effects as a supplement for improving various aspects of hair and nails in a randomized, double-blind, placebo-controlled clinical trial. Methods. A total of 50 females were included and randomized into two groups. The active group (n = 25) received 2 capsules containing Cynatine HNS, comprised of Cynatine brand keratin (500 mg) plus vitamins and minerals, per day, and the placebo group (n = 25) received 2 identical capsules of maltodextrin per day for 90 days. End points for hair loss, hair growth, hair strength, amino acid composition, and hair luster were measured. End points were also measured for nail strength and the appearance of nails. Results. The results show that subjects taking Cynatine HNS showed statistically significant improvements in their hair and nails when compared to placebo. Conclusion. Cynatine HNS is an effective supplement for improving hair and nails in 90 days or less. EudraCT number is 2014-002645-22. PMID:25386609

  15. The Effect of Psychological State and Social Support on Nail-Biting in Adolescents: An Exploratory Study

    ERIC Educational Resources Information Center

    Sisman, Fatma Nevin; Tok, Ozlem; Ergun, Ayse

    2017-01-01

    Nail-biting is one of the most common behavioral problems in children. This study aimed to examine factors affecting nail-biting among adolescents and the effects of psychological state and social support on nail-biting. This cross-sectional study was conducted between January and May of 2014 in seven schools in Istanbul (N = 724). Data were…

  16. Deformation and stress change associated with plate interaction at subduction zones: a kinematic modelling

    NASA Astrophysics Data System (ADS)

    Zhao, Shaorong; Takemoto, Shuzo

    2000-08-01

    The interseismic deformation associated with plate coupling at a subduction zone is commonly simulated by the steady-slip model in which a reverse dip-slip is imposed on the down-dip extension of the locked plate interface, or by the backslip model in which a normal slip is imposed on the locked plate interface. It is found that these two models, although totally different in principle, produce similar patterns for the vertical deformation at a subduction zone. This suggests that it is almost impossible to distinguish between these two models by analysing only the interseismic vertical deformation observed at a subduction zone. The steady-slip model cannot correctly predict the horizontal deformation associated with plate coupling at a subduction zone, a fact that is proved by both the numerical modelling in this study and the GPS (Global Positioning System) observations near the Nankai trough, southwest Japan. It is therefore inadequate to simulate the effect of the plate coupling at a subduction zone by the steady-slip model. It is also revealed that the unphysical assumption inherent in the backslip model of imposing a normal slip on the locked plate interface makes it impossible to predict correctly the horizontal motion of the subducted plate and the stress change within the overthrust zone associated with the plate coupling during interseismic stages. If the analysis made in this work is proved to be correct, some of the previous studies on interpreting the interseismic deformation observed at several subduction zones based on these two models might need substantial revision. On the basis of the investigations on plate interaction at subduction zones made using the finite element method and the kinematic/mechanical conditions of the plate coupling implied by the present plate tectonics, a synthesized model is proposed to simulate the kinematic effect of the plate interaction during interseismic stages. A numerical analysis shows that the proposed model

  17. Simulating faults and plate boundaries with a transversely isotropic plasticity model

    NASA Astrophysics Data System (ADS)

    Sharples, W.; Moresi, L. N.; Velic, M.; Jadamec, M. A.; May, D. A.

    2016-03-01

    In mantle convection simulations, dynamically evolving plate boundaries have, for the most part, been represented using an visco-plastic flow law. These systems develop fine-scale, localized, weak shear band structures which are reminiscent of faults but it is a significant challenge to resolve the large- and the emergent, small-scale-behavior. We address this issue of resolution by taking into account the observation that a rock element with embedded, planar, failure surfaces responds as a non-linear, transversely isotropic material with a weak orientation defined by the plane of the failure surface. This approach partly accounts for the large-scale behavior of fine-scale systems of shear bands which we are not in a position to resolve explicitly. We evaluate the capacity of this continuum approach to model plate boundaries, specifically in the context of subduction models where the plate boundary interface has often been represented as a planar discontinuity. We show that the inclusion of the transversely isotropic plasticity model for the plate boundary promotes asymmetric subduction from initiation. A realistic evolution of the plate boundary interface and associated stresses is crucial to understanding inter-plate coupling, convergent margin driven topography, and earthquakes.

  18. Multiscale modeling of growth plate cartilage mechanobiology.

    PubMed

    Gao, Jie; Williams, John L; Roan, Esra

    2017-04-01

    Growth plate chondrocytes are responsible for bone growth through proliferation and differentiation. However, the way they experience physiological loads and regulate bone formation, especially during the later developmental phase in the mature growth plate, is still under active investigation. In this study, a previously developed multiscale finite element model of the growth plate is utilized to study the stress and strain distributions within the cartilage at the cellular level when rapidly compressed to 20 %. Detailed structures of the chondron are included in the model to examine the hypothesis that the same combination of mechanoregulatory signals shown to maintain cartilage or stimulate osteogenesis or fibrogenesis in the cartilage anlage or fracture callus also performs the same function at the cell level within the chondrons of growth plate cartilage. Our cell-level results are qualitatively and quantitatively in agreement with tissue-level theories when both hydrostatic cellular stress and strain are considered simultaneously in a mechanoregulatory phase diagram similar to that proposed at the tissue level by Claes and Heigele for fracture healing. Chondrocytes near the reserve/proliferative zone border are subjected to combinations of high compressive hydrostatic stresses ([Formula: see text] MPa), and cell height and width strains of [Formula: see text] to [Formula: see text] respectively, that maintain cartilage and keep chondrocytes from differentiating and provide conditions favorable for cell division, whereas chondrocytes closer to the hypertrophic/calcified zone undergo combinations of lower compressive hydrostatic stress ([Formula: see text] MPa) and cell height and width strains as low as [Formula: see text] to +4 %, respectively, that promote cell differentiation toward osteogenesis; cells near the outer periphery of the growth plate structure experience a combination of low compressive hydrostatic stress (0 to [Formula: see text] MPa) and

  19. Treatment of humeral shaft fractures using antegrade nailing: functional outcome in the shoulder.

    PubMed

    Patino, Juan Martin

    2015-08-01

    The purpose of this study was to evaluate shoulder outcomes and function after humeral shaft fractures treated with antegrade nailing. Thirty patients with acute humeral shaft fractures who underwent antegrade locked intramedullary nailing were retrospectively studied. Range of motion (ROM) of the affected shoulder was evaluated, comparing it with the nonaffected shoulder, radiologic position of the nails, complications, and need for a second surgery. The study enrolled 20 men and 10 women (average age, 41.9 years). The average follow-up was 35.8 months. The average shoulder elevation averaged 157°, internal rotation was variable (reaching the sacroiliac joint to T7), and external rotation averaged 75°. Elbow flexion-extension ROM averaged 133° (115°-145°). According to the Rodriguez-Merchan criteria, 12 patients achieved excellent results (40%), 7 good (20%), and 6 fair (23.3%); poor results were found in 5 cases (16.6%). Twelve patients achieved full mobility of the shoulder, whereas 18 had some loss of motion, with significant differences between the affected and nonaffected shoulders (P = .001). Decreased shoulder ROM is common after antegrade nailing of humeral shaft fractures. Avoidance of nail impingement can improve final outcomes. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. White Nail Radio Transmitter: Billion Dollar Savings through Energy Efficiency

    DTIC Science & Technology

    2011-05-10

    increase efficiency and reduce overall energy consumption ashore by 50 percent CNO, Navy Energy Vision, P 10 White Nail Vision Your Cell Phone Cell...Estimated Total Number of transmitters 3,000,000 Estimated total power saved Watt 1,250,000,000 Cell Phone Transmitter Efficiency 1.25 Gigawatts saved...Greenhouse Gas Power 4 1 Energy Navy Use 7.3 Billion kWh White Nail Cell Phone Savings 11 Billion kWh One and a half times!!! Saves the output of four of

  1. Modeling the influence of plate motions on subduction

    NASA Astrophysics Data System (ADS)

    Hillebrand, Bram; Thieulot, Cedric; van den Berg, Arie; Spakman, Wim

    2014-05-01

    Subduction zones are widely studied complex geodynamical systems. Their evolution is influenced by a broad range of parameters such as the age of the plates (both subducting and overriding) as well as their rheology, their nature (oceanic or continental), the presence of a crust and the involved plate motions to name a few. To investigate the importance of these different parameters on the evolution of subduction we have created a series of 2D numerical thermomechanical subduction models. These subduction models are multi-material flow models containing continental and oceanic crusts, a lithosphere and a mantle. We use the sticky air approach to allow for topography build up in the model. In order to model multi-material flow in our Eulerian finite element code of SEPRAN (Segal and Praagman, 2000) we use the well benchmarked level set method (Osher and Sethian, 1988) to track the different materials and their mode of deformation through the model domain. To our knowledge the presented results are the first subduction model results with the level set method. We will present preliminary results of our parametric study focusing mainly on the influence of plate motions on the evolution of subduction. S. Osher and J.A. Sethian. Fronts propagating with curvature-dependent speed: Algorithms based on hamilton-jacobi formulations. JCP 1988 A. Segal and N.P. Praagman. The SEPRAN package. Technical report, 2000 This research is funded by The Netherlands Research Centre for Integrated Solid Earth Science (ISES)

  2. Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire.

    PubMed

    Metikala, Sreenivasulu; Mohammed, Riazuddin

    2011-07-01

    Extracting broken segments of intramedullay nails from long bones can be an operative challenge, particularly from the distal end. We report a case series where a simple and reproducible technique of extracting broken femoral cannulated nails using a ball-tipped guide wire is described. This closed technique involves no additional equipment or instruments. Eight patients who underwent the described method were included in the study. The technique involves using a standard plain guide wire passed through the cannulated distal broken nail segment after extraction of the proximal nail fragment. The plain guide wire is then advanced distally into the knee joint carefully under fluoroscopy imaging. Over this wire, a 5-millimeter (mm) cannulated large drill bit is used to create a track up to the distal broken nail segment. Through the small knee wound, a ball-tipped guide wire is passed, smooth end first, till the ball engages the end of the nail. The guide wire is then extracted along with the broken nail through the proximal wound. The method was successfully used in all eight patients for removal of broken cannulated intramedullary nail from the femoral canal without any complications. All patients underwent exchange nailing with successful bone union in six months. None of the patients had any problems at the knee joint at the final follow-up. We report a technique for successful extraction of the distal fragment of broken femoral intramedullary nails without additional surgical approaches.

  3. Comparison of our self-designed rotary self-locking intramedullary nail and interlocking intramedullary nail in the treatment of long bone fractures

    PubMed Central

    2014-01-01

    Objective The purpose of this study is to compare the clinical effects of our self-designed rotary self-locking intramedullary nail (RSIN) and interlocking intramedullary nail (IIN) for long bone fractures. Methods A retrospective study was performed in 1,704 patients who suffered bone fractures and underwent RSIN or IIN operation in our hospital between March 1999 and March 2013, including 494 with femoral fractures, 572 with humeral fractures, and 638 with tibial fractures. Among them, 634 patients were followed up for more than 1 year. The operative time, intraoperative blood loss, postoperative complications, healing rate, and the excellent and good rate of functional recovery were compared between two groups. Results Compared with IIN group, RSIN group exhibited significantly shorter operative time and less intraoperative blood loss no matter for humeral, femoral, or tibial fractures (all p < 0.001). The healing rate in patients with more than 1 year follow-up was significantly higher in RSIN group for femoral and tibial fractures (both p < 0.05). In RSIN group, no nail breakage or loosening occurred, but radial nerve injury and incision infection were respectively observed in one patient with humeral fracture. In IIN group, nail breakage or loosening occurred in 7 patients with femoral fractures and 16 patients with tibial fractures, radial nerve injury was observed in 8 patients with humeral fractures, and incision infection was present in 2 patients with humeral fractures and 1 patient with femoral fracture. The complication rate of IIN group was significantly higher than that of RSIN group (p < 0.05). However, there were no significant differences in the excellent and good rate of shoulder, elbow, knee, and ankle joint functional recovery between RSIN group and IIN group. Conclusion RSIN may be a reliable and practical alternative method for the treatment of long bone fractures. PMID:25047454

  4. Comparison of our self-designed rotary self-locking intramedullary nail and interlocking intramedullary nail in the treatment of long bone fractures.

    PubMed

    Liu, Bailian; Xiong, Ying; Deng, Hong; Gu, Shao; Jia, Fu; Li, Qunhui; Wang, Daxing; Gan, Xuewen; Liu, Wei

    2014-07-21

    The purpose of this study is to compare the clinical effects of our self-designed rotary self-locking intramedullary nail (RSIN) and interlocking intramedullary nail (IIN) for long bone fractures. A retrospective study was performed in 1,704 patients who suffered bone fractures and underwent RSIN or IIN operation in our hospital between March 1999 and March 2013, including 494 with femoral fractures, 572 with humeral fractures, and 638 with tibial fractures. Among them, 634 patients were followed up for more than 1 year. The operative time, intraoperative blood loss, postoperative complications, healing rate, and the excellent and good rate of functional recovery were compared between two groups. Compared with IIN group, RSIN group exhibited significantly shorter operative time and less intraoperative blood loss no matter for humeral, femoral, or tibial fractures (all p < 0.001). The healing rate in patients with more than 1 year follow-up was significantly higher in RSIN group for femoral and tibial fractures (both p < 0.05). In RSIN group, no nail breakage or loosening occurred, but radial nerve injury and incision infection were respectively observed in one patient with humeral fracture. In IIN group, nail breakage or loosening occurred in 7 patients with femoral fractures and 16 patients with tibial fractures, radial nerve injury was observed in 8 patients with humeral fractures, and incision infection was present in 2 patients with humeral fractures and 1 patient with femoral fracture. The complication rate of IIN group was significantly higher than that of RSIN group (p < 0.05). However, there were no significant differences in the excellent and good rate of shoulder, elbow, knee, and ankle joint functional recovery between RSIN group and IIN group. RSIN may be a reliable and practical alternative method for the treatment of long bone fractures.

  5. Transfer function modeling of damping mechanisms in viscoelastic plates

    NASA Technical Reports Server (NTRS)

    Slater, J. C.; Inman, D. J.

    1991-01-01

    This work formulates a method for the modeling of material damping characteristics in plates. The Sophie German equation of classical plate theory is modified to incorporate hysteresis effects represented by complex stiffness using the transfer function approach proposed by Golla and Hughes, (1985). However, this procedure is not limited to this representation. The governing characteristic equation is decoupled through separation of variables, yielding a solution similar to that of undamped classical plate theory, allowing solution of the steady state as well as the transient response problem.

  6. 78 FR 68472 - Steel Nails From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-14

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1114 (Review)] Steel Nails From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping Duty Order on Steel Nails From China... steel nails from China would be likely to lead to continuation or recurrence of material injury within a...

  7. Modeling of laser welding of steel and titanium plates with a composite insert

    NASA Astrophysics Data System (ADS)

    Isaev, V. I.; Cherepanov, A. N.; Shapeev, V. P.

    2017-10-01

    A 3D model of laser welding proposed before by the authors was extended to the case of welding of metallic plates made of dissimilar materials with a composite multilayer intermediate insert. The model simulates heat transfer in the welded plates and takes into account phase transitions. It was proposed to select the composition of several metals and dimensions of the insert to avoid the formation of brittle intermetallic phases in the weld joint negatively affecting its strength properties. The model accounts for key physical phenomena occurring during the complex process of laser welding. It is capable to calculate temperature regimes at each point of the plates. The model can be used to select the welding parameters reducing the risk of formation of intermetallic plates. It can forecast the dimensions and crystalline structure of the solidified melt. Based on the proposed model a numerical algorithm was constructed. Simulations were carried out for the welding of titanium and steel plates with a composite insert comprising four different metals: copper and niobium (intermediate plates) with steel and titanium (outer plates). The insert is produced by explosion welding. Temperature fields and the processes of melting, evaporation, and solidification were studied.

  8. Minimally invasive plating osteosynthesis for mid-distal third humeral shaft fractures.

    PubMed

    Lian, Kejian; Wang, Lei; Lin, Dasheng; Chen, Zhiwen

    2013-08-01

    Mid-distal third humeral shaft fractures can be effectively treated with minimally invasive plating osteosynthesis and intramedullary nailing (IMN). However, these 2 treatments have not been adequately compared. Forty-seven patients (47 fractures) with mid-distal third humeral shaft fractures were randomly allocated to undergo either minimally invasive plating osteosynthesis (n=24) or IMN (n=23). The 2 groups were similar in terms of fracture patterns, fracture location, age, and associated injuries. Intraoperative measurements included blood loss and operative time. Clinical outcome measurements included fracture healing, radial nerve recovery, and elbow and shoulder discomfort. Radiographic measurements included fracture alignment, time to healing, delayed union, and nonunion. Functional outcome was satisfactory in both groups. Mean American Shoulder and Elbow Surgeons score and Mayo score were both better for the minimally invasive plating osteosynthesis group than for the IMN group (98.2 vs 97.6, respectively, and 93.5 vs 94.1, respectively; P<.001). Operative time was shorter and less intraoperative blood loss occurred in the minimally invasive plating osteosynthesis group than in the IMN group. Average time to union was similar in both groups. Primary union was achieved in 23 of 24 patients in the minimally invasive plating osteosynthesis group and in 22 of 23 in the IMN group. Minimally invasive plating osteosynthesis may have outcomes comparable with IMN for the management of mid-distal third humeral shaft fractures. Minimally invasive plating osteosynthesis is more suitable for complex fractures, especially for radial protection and motion recovery of adjacent joints, compared with IMN for simple fractures. Copyright 2013, SLACK Incorporated.

  9. Reverse Less Invasive Stabilization System (LISS) Plating for Proximal Femur Fractures in Poliomyelitis Survivors: A Report of Two Cases.

    PubMed

    Yao, Chen; Jin, Dongxu; Zhang, Changqing

    2017-11-15

    BACKGROUND Poliomyelitis is a neuromuscular disease which causes muscle atrophy, skeletal deformities, and disabilities. Treatment of hip fractures on polio-affect limbs is unique and difficult, since routine fixation methods like nailing may not be suitable due to abnormal skeletal structures. CASE REPORT We report one femoral neck fracture and one subtrochanteric fracture in polio survivors successfully treated with reverse less invasive stabilization system (LISS) plating technique. Both fractures were on polio-affected limbs with significant skeletal deformities and low bone density. A contralateral femoral LISS plate was applied upside down to the proximal femur as an internal fixator after indirect or direct reduction. Both patients had uneventful bone union and good functional recovery. CONCLUSIONS Reverse LISS plating is a safe and effective technique to treat hip fractures with skeletal deformities caused by poliomyelitis.

  10. An Experimentally Validated Numerical Modeling Technique for Perforated Plate Heat Exchangers

    PubMed Central

    Nellis, G. F.; Kelin, S. A.; Zhu, W.; Gianchandani, Y.

    2010-01-01

    Cryogenic and high-temperature systems often require compact heat exchangers with a high resistance to axial conduction in order to control the heat transfer induced by axial temperature differences. One attractive design for such applications is a perforated plate heat exchanger that utilizes high conductivity perforated plates to provide the stream-to-stream heat transfer and low conductivity spacers to prevent axial conduction between the perforated plates. This paper presents a numerical model of a perforated plate heat exchanger that accounts for axial conduction, external parasitic heat loads, variable fluid and material properties, and conduction to and from the ends of the heat exchanger. The numerical model is validated by experimentally testing several perforated plate heat exchangers that are fabricated using microelectromechanical systems based manufacturing methods. This type of heat exchanger was investigated for potential use in a cryosurgical probe. One of these heat exchangers included perforated plates with integrated platinum resistance thermometers. These plates provided in situ measurements of the internal temperature distribution in addition to the temperature, pressure, and flow rate measured at the inlet and exit ports of the device. The platinum wires were deposited between the fluid passages on the perforated plate and are used to measure the temperature at the interface between the wall material and the flowing fluid. The experimental testing demonstrates the ability of the numerical model to accurately predict both the overall performance and the internal temperature distribution of perforated plate heat exchangers over a range of geometry and operating conditions. The parameters that were varied include the axial length, temperature range, mass flow rate, and working fluid. PMID:20976021

  11. An Experimentally Validated Numerical Modeling Technique for Perforated Plate Heat Exchangers.

    PubMed

    White, M J; Nellis, G F; Kelin, S A; Zhu, W; Gianchandani, Y

    2010-11-01

    Cryogenic and high-temperature systems often require compact heat exchangers with a high resistance to axial conduction in order to control the heat transfer induced by axial temperature differences. One attractive design for such applications is a perforated plate heat exchanger that utilizes high conductivity perforated plates to provide the stream-to-stream heat transfer and low conductivity spacers to prevent axial conduction between the perforated plates. This paper presents a numerical model of a perforated plate heat exchanger that accounts for axial conduction, external parasitic heat loads, variable fluid and material properties, and conduction to and from the ends of the heat exchanger. The numerical model is validated by experimentally testing several perforated plate heat exchangers that are fabricated using microelectromechanical systems based manufacturing methods. This type of heat exchanger was investigated for potential use in a cryosurgical probe. One of these heat exchangers included perforated plates with integrated platinum resistance thermometers. These plates provided in situ measurements of the internal temperature distribution in addition to the temperature, pressure, and flow rate measured at the inlet and exit ports of the device. The platinum wires were deposited between the fluid passages on the perforated plate and are used to measure the temperature at the interface between the wall material and the flowing fluid. The experimental testing demonstrates the ability of the numerical model to accurately predict both the overall performance and the internal temperature distribution of perforated plate heat exchangers over a range of geometry and operating conditions. The parameters that were varied include the axial length, temperature range, mass flow rate, and working fluid.

  12. Effect of Shear Deformation and Continuity on Delamination Modelling with Plate Elements

    NASA Technical Reports Server (NTRS)

    Glaessgen, E. H.; Riddell, W. T.; Raju, I. S.

    1998-01-01

    The effects of several critical assumptions and parameters on the computation of strain energy release rates for delamination and debond configurations modeled with plate elements have been quantified. The method of calculation is based on the virtual crack closure technique (VCCT), and models that model the upper and lower surface of the delamination or debond with two-dimensional (2D) plate elements rather than three-dimensional (3D) solid elements. The major advantages of the plate element modeling technique are a smaller model size and simpler geometric modeling. Specific issues that are discussed include: constraint of translational degrees of freedom, rotational degrees of freedom or both in the neighborhood of the crack tip; element order and assumed shear deformation; and continuity of material properties and section stiffness in the vicinity of the debond front, Where appropriate, the plate element analyses are compared with corresponding two-dimensional plane strain analyses.

  13. Practical Aspects of Posttrauma Reconstruction With an Intramedullary Lengthening Nail

    PubMed Central

    2017-01-01

    Summary: Limb equalization using the Ilizarov method has evolved and adapted the use of internal lengthening devices. One of the newest devices, termed “PRECICE,” is a magnetically controlled telescoping nail. Complications such as pin site infection and skin irritation are eliminated. Despite trauma surgeons’ familiarity with intramedullary nailing, the Ilizarov method requires sound knowledge of deformity analysis and awareness of specific complications associated with distraction osteogenesis. This manuscript discusses some of the practical preoperative and intraoperative components of limb lengthening. PMID:28486286

  14. [The direct AAS determination of micro elements in hair and nail by base-digestion].

    PubMed

    Ju, Hong-fang

    2002-08-01

    The study of micro elements is more and more extensively, and people can gain some informations by the level of micro elements in tissue. This paper tempts to dissolve hair or nail in 2 mol.L-1 NaOH and determinate nine micro elements including calcium, zinc, iron, manganese, nickel, cadmium, copper, lead and bismuth in them by base-digestion with FAAS and GFAAS. It shows that the measured value of these elements is coincident with reference articles reported, except bismuth. The elements' percent recoveries are 90.0%-110.8%. The result also shows that the level of zinc and copper in hair are higher than in nail, and the level of bismuth, cadmium and iron in hair are lower than in nail, but the level of micro elements in hair and in nail are not correlative.

  15. Fundamental structure model of island arcs and subducted plates in and around Japan

    NASA Astrophysics Data System (ADS)

    Iwasaki, T.; Sato, H.; Ishiyama, T.; Shinohara, M.; Hashima, A.

    2015-12-01

    The eastern margin of the Asian continent is a well-known subduction zone, where the Pacific (PAC) and Philippine Sea (PHS) plates are being subducted. In this region, several island arcs (Kuril, Northeast Japan, Southwest Japan, Izu-Bonin and Ryukyu arcs) meet one another to form a very complicated tectonic environment. At 2014, we started to construct fundamental structure models for island arcs and subducted plates in and around Japan. Our research is composed of 6 items of (1) topography, (2) plate geometry, (3) fault models, (4) the Moho and brittle-ductile transition zone, (5) the lithosphere-asthenosphere boundary, and (6) petrological/rheological models. Such information is basic but inevitably important in qualitative understanding not only for short-term crustal activities in the subduction zone (particularly caused by megathrust earthquakes) but also for long-term cumulative deformation of the arcs as a result of strong plate-arc/arc-arc interactions. This paper is the first presentation of our research, mainly presenting the results of items (1) and (2). The area of our modelling is 12o-54o N and 118o-164o E to cover almost the entire part of Japanese Islands together with Kuril, Ryukyu and Izu-Bonin trenches. The topography model was constructed from the 500-m mesh data provided from GSJ, JODC, GINA and Alaska University. Plate geometry models are being constructed through the two steps. In the first step, we modelled very smooth plate boundaries of the Pacific and Philippine Sea plates in our whole model area using 42,000 earthquake data from JMA, USGS and ISC. For 7,800 cross sections taken with several directions to the trench axes, 2D plate boundaries were defined by fitting to the earthquake distribution (the Wadati-Benioff zone), from which we obtained equi-depth points of the plate boundary. These equi-depth points were then approximated by spline interpolation technique to eliminate shorter wave length undulation (<50-100 km). The obtained

  16. Arthrodesis After Infected Revision TKA: Retrospective Comparison of Intramedullary Nailing and External Fixation.

    PubMed

    Iacono, Francesco; Francesco, Iacono; Raspugli, Giovanni Francesco; Francesco, Raspugli Giovanni; Bruni, Danilo; Danilo, Bruni; Lo Presti, Mirco; Mirco, Lo Presti; Sharma, Bharat; Bharat, Sharma; Akkawi, Ibrahim; Ibrahim, Akkawi; Marcacci, Maurilio; Maurilio, Marcacci

    2013-10-01

    Infection after revision total knee arthroplasty (TKA) for previous septic TKA can be a challenging problem to treat due to loss of bone stock and soft tissue integrity. In these cases, arthrodesis is a well-recognized salvage procedure. The aim of this retrospective study was to compare the results as described by a Visual Analogue Scale (VAS) and the Lequesne Algofunctional Score (LAS) of knee arthrodeses performed by using either an external fixator (EF) or an intramedullary nail (IM). The study included 34 knee arthrodesis divided in two groups: first group included 12 patients treated with EF and the second group of 22 patients dealt with IM nail. Clinical and functional evaluation was performed using the VAS and the LAS. Full-length radiographs were used to verify limb length discrepancy. VAS and LAS results showed a substantial improvement relative to preoperative condition in both groups. However, the LAS was significantly better in the IM nail group. The mean leg length discrepancy was significantly greater (4.5 cm) in the first group than in the second one (0.8 cm). No recurrence of infection was observed in the EF group while there were three recurrent infections in the IM nail group. Our study supported the existing literature and found that reinfection after revision TKA can be effectively treated with arthrodesis. In presence of massive bone loss, we recommend arthrodesis with IM nail used as an endoprosthesis, without bone-on-bone fusion, to produce a stable and painless knee, while preserving the limb length. Use of an IM nail allowed us to get a better functional result than EF.

  17. Classification Model for Damage Localization in a Plate Structure

    NASA Astrophysics Data System (ADS)

    Janeliukstis, R.; Ruchevskis, S.; Chate, A.

    2018-01-01

    The present study is devoted to the problem of damage localization by means of data classification. The commercial ANSYS finite-elements program was used to make a model of a cantilevered composite plate equipped with numerous strain sensors. The plate was divided into zones, and, for data classification purposes, each of them housed several points to which a point mass of magnitude 5 and 10% of plate mass was applied. At each of these points, a numerical modal analysis was performed, from which the first few natural frequencies and strain readings were extracted. The strain data for every point were the input for a classification procedure involving k nearest neighbors and decision trees. The classification model was trained and optimized by finetuning the key parameters of both algorithms. Finally, two new query points were simulated and subjected to a classification in terms of assigning a label to one of the zones of the plate, thus localizing these points. Damage localization results were compared for both algorithms and were found to be in good agreement with the actual application positions of point load.

  18. Hydrodynamics of a flexible plate between pitching rigid plates

    NASA Astrophysics Data System (ADS)

    Kim, Junyoung; Kim, Daegyoum

    2017-11-01

    The dynamics of a flexible plate have been studied as a model problem in swimming and flying of animals and fluid-structure interaction of plants and flags. Motivated by fish schooling and an array of sea grasses, we investigate the dynamics of a flexible plate closely placed between two pitching rigid plates. In most studies on passive deformation of the flexible plate, the plate is immersed in a uniform flow or a wavy flow. However, in this study, the flexible plate experiences periodic deformation by the oscillatory flow generated by the prescribed pitching motion of the rigid plates. In our model, the pitching axes of the rigid plates and the clamping position of the flexible plate are aligned on the same line. The flexible plate shows various responses depending on length and pitching frequency of rigid plates, thickness of a flexible plate, and free-stream velocity. To find the effect of each variable on the response of the flexible plate, amplitude of a trailing edge and modal contribution of a flapping motion are compared, and flow structure around the flexible plate is examined.

  19. Readout models for BaFBr0.85I0.15:Eu image plates

    NASA Astrophysics Data System (ADS)

    Stoeckl, M.; Solodov, A. A.

    2018-06-01

    The linearity of the photostimulated luminescence process makes repeated image-plate scanning a viable technique to extract a more dynamic range. In order to obtain a response estimate, two semi-empirical models for the readout fading of an image plate are introduced; they relate the depth distribution of activated photostimulated luminescence centers within an image plate to the recorded signal. Model parameters are estimated from image-plate scan series with BAS-MS image plates and the Typhoon FLA 7000 scanner for the hard x-ray image-plate diagnostic over a collection of experiments providing x-ray energy spectra whose approximate shape is a double exponential.

  20. Fractures above and below a modular nail for knee arthrodesis. A case report.

    PubMed

    Hinarejos, Pedro; Ginés, Alberto; Monllau, Juan C; Puig, Lluis; Cáceres, Enric

    2005-06-01

    Several techniques have been advocated for knee arthrodesis, and there has been an increasing interest in modular intramedullary nails in the recent last years. We report a case of femoral and tibial fractures at each end of a modular nail in a solidly fused knee 8 months after an arthrodesis.

  1. Thermal vibration of rectangular single-layered black phosphorus predicted by orthotropic plate model

    NASA Astrophysics Data System (ADS)

    Zhang, Yiqing; Wang, Lifeng; Jiang, Jingnong

    2018-03-01

    Vibrational behavior is very important for nanostructure-based resonators. In this work, an orthotropic plate model together with a molecular dynamics (MD) simulation is used to investigate the thermal vibration of rectangular single-layered black phosphorus (SLBP). Two bending stiffness, two Poisson's ratios, and one shear modulus of SLBP are calculated using the MD simulation. The natural frequency of the SLBP predicted by the orthotropic plate model agrees with the one obtained from the MD simulation very well. The root of mean squared (RMS) amplitude of the SLBP is obtained by MD simulation and the orthotropic plate model considering the law of energy equipartition. The RMS amplitude of the thermal vibration of the SLBP is predicted well by the orthotropic plate model compared to the MD results. Furthermore, the thermal vibration of the SLBP with an initial stress is also well-described by the orthotropic plate model.

  2. The study on length and diameter ratio of nail as preliminary design for slope stabilization

    NASA Astrophysics Data System (ADS)

    Gunawan, Indra; Silmi Surjandari, Niken; Muslih Purwana, Yusep

    2017-11-01

    Soil nailing technology has been widely applied in practice for reinforced slope. The number of studies for the effective design of nail-reinforced slopes has also increased. However, most of the previous study was focused on a safety factor of the slope; the ratio of length and diameter itself has likely never been studied before. The aim of this study is to relate the length and diameter ratio of the nail with the safety factor of the 20 m height of sand slope in the various angle of friction and steepness of the slope. Simplified Bishop method was utilized to analyze the safety factor of the slope. This study is using data simulation to calculate the safety factor of the slope with soil nailing reinforcement. The results indicate that safety factor of slope stability increases with the increase of length and diameter ratio of the nail. At any angle of friction and steepness of the slope, certain effective length and diameter ratio was obtain. These results may be considered as a preliminary design for slope stabilization.

  3. Intramedullary nailing: evolutions of femoral intramedullary nailing: first to fourth generations.

    PubMed

    Russell, Thomas A

    2011-12-01

    Intramedullary femoral nailing is the gold standard for femoral shaft fixation but only in the past 27 years. This rapid replacement of closed traction and cast techniques in North America was a controversial and contentious evolution in surgery. As we enter the fourth generation of implant design, capabilities, and surgical technique, it is important to understand the driving forces for this technology. These forces included changes in radiographic imaging capabilities, biomaterial design and computer-assisted manufacturing, and the recognition of the importance of mobilization of the trauma patient to avoid systemic complications and optimize functional recovery.

  4. Hierarchic plate and shell models based on p-extension

    NASA Technical Reports Server (NTRS)

    Szabo, Barna A.; Sahrmann, Glenn J.

    1988-01-01

    Formulations of finite element models for beams, arches, plates and shells based on the principle of virtual work was studied. The focus is on computer implementation of hierarchic sequences of finite element models suitable for numerical solution of a large variety of practical problems which may concurrently contain thin and thick plates and shells, stiffeners, and regions where three dimensional representation is required. The approximate solutions corresponding to the hierarchic sequence of models converge to the exact solution of the fully three dimensional model. The stopping criterion is based on: (1) estimation of the relative error in energy norm; (2) equilibrium tests, and (3) observation of the convergence of quantities of interest.

  5. Periprosthetic supracondylar femoral fractures following total knee arthroplasty: clinical comparison and related complications of the femur plate system and retrograde-inserted supracondylar nail.

    PubMed

    Gondalia, Viral; Choi, Duck Hyun; Lee, Su Chan; Nam, Chang Hyun; Hwang, Bo Hyun; Ahn, Hye Sun; Ong, Alvin C; Park, Ha Young; Jung, Kwang Am

    2014-09-01

    The purpose of this study is to analyze the clinical results and related complications of the femur plate system (FP) and the retrograde-inserted supracondylar nail (RISN). The study included 42 cases of periprosthetic supracondylar femoral fractures (PSF) proximal to posterior stabilized total knee arthroplasty between 2005 and 2009. Twenty-four cases of PSF were treated with the FP, and the other 18 cases were treated with the RISN. This study cohort was divided into subgroups according to the AO classification. We retrospectively compared the clinical results between the FP and RISN group. There were no significant differences between the two groups in terms of time of clinical union (p = 0.649). In the subgroup analysis, the mean operation time was significantly different only in subgroup A1 (p = 0.03). Complications were seen in 29.2 % (7/24) of patients in the FP group and 27.8 % (5/18) in the RISN group. The age during the index TKA and fracture fixation was a significant risk (p = 0.008) factor for complications between the two groups. No significant differences were found in the other factors between the two groups. The p value for operative time (p = 0.223), immobilization period (p = 0.129), ROM (p = 0.573), KSS (p = 0.379), KSS functional scores (p = 0.310) and time to union (p = 0.649). Clinical results did not differ according to the treatment methods used. Fixation method and fracture type did not cause an increase in the complication rate, but there was a trend toward higher non-union rates with the FP method and higher re-fracture rate with the RISN method. Noting the fact that only increasing age correlated with an increased complication rate, more careful attention should be paid to elderly patients in terms of both prevention and surgical care. Level III, therapeutic study.

  6. [Tibiotalocalcaneal arthrodesis using a distally introduced femur nail (DFN)].

    PubMed

    Grass, René

    2005-10-01

    Simultaneous arthrodesis of ankle and subtalar joints and, at the same sitting, correction of axial malalignment of hindfoot, treatment of bony defects and of sequelae of circulatory disturbances after multiple previous interventions. Internal stabilization with a short distal femur nail. Restitution of a pain-free weight bearing. Failure of arthrodesis of ankle and subtalar joint causing pain in patients with severely altered bone structures particularly at the level of the talar dome. Malalignment of hind- and/or forefoot after previous arthrodesis of ankle and subtalar joint. Failure of conservative therapy in both above-enumerated conditions. Poor skin or soft-tissue conditions. Reflex sympathetic dystrophy. Acute osteitis/osteomyelitis. Posterolateral approach. Resection of the articular cartilage and the areas of sclerosis of the ankle and of the posterior facet of the subtalar joint. Interposition of bone grafts harvested from the iliac crest. Correction of malalignment of hind- and forefoot. Locked nailing with a short distal femur nail. Fitting of a flexible custom-made arthrodesis boot; weight bearing in boot not exceeding half of body weight until the 8th week. Gait training. After 12 weeks wearing of normal shoes. Radiographs after 6 and 12 weeks. Between February 1, 2002 and September 1, 2003 this technique was performed on 18 feet in 17 patients (three women, 14 men, average age 53 years [38.9-73.7 years]). Average duration of follow-up: 1.2 years (0.6-2.1 years). The goal of surgery was reached in all patients. Subjective assessment: 14 times good, three times satisfactory. Four complications: one loss of nail purchase, one dislocation of locking screw, one breakage of locking bolt, one prolonged bone healing.

  7. [Intramedullary nailing of the tibia with the expert tibia nail].

    PubMed

    Hansen, Matthias; El Attal, René; Blum, Jochen; Blauth, Michael; Rommens, Pol Maria

    2009-12-01

    Restoration of axis, length, and rotation of the lower leg. Sufficient primary stability of the osteosynthesis for functional aftercare. Early functional aftercare to maintain joint mobility. Good bony healing in closed and open fractures. All closed and open fractures of the tibia and complete lower leg fractures (AO 42). Certain extraarticular fractures of the proximal and distal tibia (AO 41 A2/A3; AO 43 A1/A2/A3). Segmental fractures of the tibia. Certain intraarticular fractures of the tibia with use of additional implants (AO 41 C1/C2; AO 43 C1/C2). Stabilization during and after segmental bone transport or callus distraction of the tibia. Patients in poor general condition (e.g., bedridden). Flexion of the knee of less than 90 degrees . Infection in the nail's insertion area. Infection of the tibial cavity. Complex articular fractures of the proximal or distal tibia with joint depression. Closed reduction of the fracture. If necessary, use of reduction clamps through additional stab incisions or open surgical procedures. In some cases, additional osteosynthesis procedures are necessary (e.g., screws). Positioning of the patient may be performed on a radiolucent table or a traction table. Opening of the proximal tibia in line with the medullary canal. Cannulated or noncannulated insertion of the Expert Tibia Nail((R)) with or without reaming of the medullary canal depending on the fracture type and soft-tissue condition. Control of axis, length, and rotation. Distal interlocking with the radiolucent drill and proximal interlocking with the targeting device. Immediate mobilization of ankle joint and knee joint. Depending on the type of fracture, mobilization with 20 kg partial weight bearing or pain-dependent full weight bearing with crutches. X-ray control 6 weeks postoperatively and increased weight bearing depending on the fracture status. In a prospective, international multicentric study, 181 patients with 186 fractures were included between July 2004 and

  8. Global geodynamic models constrained by tectonic reconstructions including plate deformation

    NASA Astrophysics Data System (ADS)

    Gurnis, M.; Flament, N.; Spasojevic, S.; Williams, S.; Seton, M.; Müller, R. D.

    2011-12-01

    In order to investigate the effect of mantle flow on the Earth's surface, imposing the kinematics predicted by plate reconstructions in global convection models has become common practice. Such models are valuable to investigate the effect of the mantle flow beneath the lithosphere on surface topography. Changes in surface topography due to lithospheric deformation are so far not part of top-down tectonic models in which plates are treated as rigid in traditional tectonic reconstructions. We introduce a new generation of geodynamic models that are based on tectonic reconstructions with deforming plates at both passive and convergent margins. These models allow us to investigate the relationships between lithospheric deformation and mantle flow, and their combined effects on surface topography. In traditional tectonic reconstructions, continents are represented as rigid blocks that either overlap or are separated by gaps in full-fit reconstructions. Reconstructions that include a global network of topological plate polygons avoid continental overlaps and gaps, but velocities are still derived on the basis of the Euler poles for rigid blocks. To resolve these issues, we developed a series of deforming plate models using the open source plate modeling software GPlates. For a given area, our methodology requires the relative motions between major rigid continental blocks, and a definition of the regions in which continental lithosphere deformed between these blocks. We use geophysical and geological data to define the limit between rigid and deforming areas, and the deformation history of non-rigid blocks. The velocity field predicted by these reconstructions is then used as a time-dependent surface boundary condition in global 3-D geodynamic models. To incorporate the continental lithosphere in our global models, we embed compositionally distinct crust and continental lithosphere within the thermal lithosphere. We define three isostatic columns of different thickness

  9. Anatomic relationship of the proximal nail matrix to the extensor hallucis longus tendon insertion.

    PubMed

    Palomo López, P; Becerro de Bengoa Vallejo, R; López López, D; Prados Frutos, J C; Alfonso Murillo González, J; Losa Iglesias, M E

    2015-10-01

    The purpose of this study was to delineate the relationship of the terminal extensor hallucis longus tendon insertion to the proximal limit of the nail matrix of the great toe. Fifty fresh-frozen human cadaver great toes with no evidence of trauma (average age, 62.5 years; 29 males and 21 females) were used for this study. Under 25X magnification, the proximal limit of the nail matrix and the terminal bony insertion of the extensor hallucis longus tendons were identified. The distance from the terminal tendon insertion to the nail matrix was ascertained using precision calipers, an optical microscope, and autocad(®) software for windows. Twenty-five great toes were placed in a neutral formalin solution and further analysed by histological longitudinal-sections. The specimens were stained with haematoxylin and eosin and examined microscopically to determine the presence of the extensor hallucis longus tendon along the dorsal aspect of the distal phalanx of each great toe. The main result we found in great toes was that the extensor tendon is between the matrix and the phalanx and extends dorsally to the distal aspect of the distal phalanx in all, 100%, specimens. The nail matrix of the great toe is not attached to the periosteum of the dorsal aspect of the base of the distal phalanx as is the case for fingers, because the extensor hallucis tendon is plantar or directly underneath the nail matrix and the tendon is dorsal to the bone. We have found that the extensor tendon is between the matrix and the phalanx and extends dorsally to the distal aspect of the distal phalanx. The nail matrix of the great toe is not attached to the periosteum of the dorsal aspect of the base of distal phalanx as is the case in fingers, because the extensor hallucis tendon is plantar or directly underneath the nail matrix and the tendon is dorsal to the bone. Our anatomic study demonstrates that the proximal limit of the matrix and nail bed of the human great toe are dorsal and

  10. ADOPT: A tool for automatic detection of tectonic plates at the surface of convection models

    NASA Astrophysics Data System (ADS)

    Mallard, C.; Jacquet, B.; Coltice, N.

    2017-08-01

    Mantle convection models with plate-like behavior produce surface structures comparable to Earth's plate boundaries. However, analyzing those structures is a difficult task, since convection models produce, as on Earth, diffuse deformation and elusive plate boundaries. Therefore we present here and share a quantitative tool to identify plate boundaries and produce plate polygon layouts from results of numerical models of convection: Automatic Detection Of Plate Tectonics (ADOPT). This digital tool operates within the free open-source visualization software Paraview. It is based on image segmentation techniques to detect objects. The fundamental algorithm used in ADOPT is the watershed transform. We transform the output of convection models into a topographic map, the crest lines being the regions of deformation (plate boundaries) and the catchment basins being the plate interiors. We propose two generic protocols (the field and the distance methods) that we test against an independent visual detection of plate polygons. We show that ADOPT is effective to identify the smaller plates and to close plate polygons in areas where boundaries are diffuse or elusive. ADOPT allows the export of plate polygons in the standard OGR-GMT format for visualization, modification, and analysis under generic softwares like GMT or GPlates.

  11. Complications of sodium hydroxide chemical matrixectomy: nail dystrophy, allodynia, hyperalgesia.

    PubMed

    Bostancı, Seher; Koçyiğit, Pelin; Güngör, Hilayda Karakök; Parlak, Nehir

    2014-11-01

    Ingrown toenails are seen most commonly in young adults, and they can seriously affect daily life. Partial nail avulsion with chemical matrixectomy, generally by using either sodium hydroxide or phenol, is one of the most effective treatment methods. Known complications of phenol matrixectomy are unpredictable tissue damage, prolonged postoperative drainage, increased secondary infection rates, periostitis, and poor cosmetic results. To our knowledge, there have been no reports about the complications related to sodium hydroxide matrixectomy. Herein, we describe three patients who developed nail dystrophy, allodynia, and hyperalgesia after sodium hydroxide matrixectomy.

  12. Prognostic Factors for Predicting Outcomes After Intramedullary Nailing of the Tibia

    PubMed Central

    Schemitsch, Emil H.; Bhandari, Mohit; Guyatt, Gordon; Sanders, David W.; Swiontkowski, Marc; Tornetta, Paul; Walter, Stephen D.; Zdero, Rad; Goslings, J.C.; Teague, David; Jeray, Kyle; McKee, Michael D.; Schemitsch, Emil H.; Bhandari, Mohit; Guyatt, Gordon; Sanders, David W.; Swiontkowski, Marc; Tornetta, Paul; Walter, Stephen D.; Zdero, Rad; Goslings, J.C.; Teague, David; Jeray, Kyle; McKee, Michael D.

    2012-01-01

    Background: Prediction of negative postoperative outcomes after long-bone fracture treatment may help to optimize patient care. We recently completed the Study to Prospectively Evaluate Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT), a large, multicenter trial of reamed and unreamed intramedullary nailing of tibial shaft fractures in 1226 patients. Using the SPRINT data, we conducted an investigation of baseline and surgical factors to determine any associations with an increased risk of adverse events within one year of intramedullary nailing. Methods: Using multivariable logistic regression analysis, we investigated fifteen baseline and surgical factors for any associations with an increased risk of negative outcomes. Results: There was an increased risk of negative events in patients with a high-energy mechanism of injury (odds ratio [OR] = 1.57; 95% confidence interval [CI], 1.05 to 2.35), a stainless steel compared with a titanium nail (OR = 1.52; 95% CI, 1.10 to 2.13), a fracture gap (OR = 2.40; 95% CI, 1.47 to 3.94), and full weight-bearing status after surgery (OR = 1.63; 95% CI, 1.00 to 2.64). There was no increased risk with the use of nonsteroidal anti-inflammatory agents, late or early time to surgery, or smoking status. Open fractures had a higher risk of events among patients treated with reamed nailing (OR = 3.26; 95% CI, 2.01 to 5.28) but not in patients treated with unreamed nailing (OR = 1.50; 95% CI, 0.92 to 2.47). Patients with open fractures who had wound management either without any additional procedures or with delayed primary closure had a decreased risk of events compared with patients who required subsequent, more complex reconstruction (OR = 0.18 [95% CI, 0.09 to 0.35] and 0.29 [95% CI, 0.14 to 0.62], respectively). Conclusions: We identified several baseline fracture and surgical characteristics that may increase the risk of adverse events in patients with tibial shaft fractures. Surgeons should consider the

  13. Several cases of undesirable effects caused by methacrylate ultraviolet-curing nail polish for non-professional use.

    PubMed

    Dahlin, Jakob; Berne, Berit; Dunér, Kari; Hosseiny, Sara; Matura, Mihály; Nyman, Gunnar; Tammela, Monica; Isaksson, Marléne

    2016-09-01

    Ultraviolet (UV)-curing nail polishes based on acrylates or methacrylates are currently also available for non-professional use. The Swedish Medical Products Agency recently prohibited one brand of UV-curing polish, because several consumers reported undesirable effects after using it. To investigate whether consumers with undesirable effects after using the UV-curing nail polish that was later prohibited were contact allergic to the polish and its individual ingredients. Eight patients who had reported severe skin reactions after the use of the UV-curing polish were patch tested with two coatings of the nail polish and its ingredients at five dermatology departments in Sweden. All patients tested except one showed contact allergic reactions to one or several of the acrylate-based or methacrylate-based ingredients in the nail polish. The non-professional use of UV-curing nail polishes poses a risk of sensitization from acrylates and methacrylates. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Nail gun-induced open-globe injuries: a 10-year retrospective review.

    PubMed

    Kolomeyer, Anton M; Shah, Avni; Bauza, Alain M; Langer, Paul D; Zarbin, Marco A; Bhagat, Neelakshi

    2014-02-01

    To describe the characteristics of nail gun-related open-globe injuries. Retrospective series of all patients presenting with open globes secondary to nail gun injury from 2000 to 2010. Data were collected on demographics, setting of accident, presenting clinical examination findings, visual acuity, management, surgical procedures needed, and long-term outcomes. Forty-two patients (43 eyes; mean age, 31.6 years; 100% male; 79% Hispanic) suffered open-globe injury from nail gun accidents. Thirty-seven eyes (86%) sustained injury at work. One of 15 (6.7%) patients, on whom data were available, wore protective eyewear during the incident. Entrance wounds were classified into Zone I (n = 24 [56%]), Zone II (n = 12 [28%]), and Zone III (n = 7 [16%]). Six eyes (14%) had retained intraocular foreign bodies. Mean presenting logarithm of the minimum angle of resolution visual acuity was 1.64 ± 0.83, whereas mean final logarithm of the minimum angle of resolution visual acuity was 1.01 ± 0.96 (P = 0.004). Two eyes (4.7%) had no light perception vision at final examination. Seventeen (40%) patients developed a traumatic cataract, and 2 (4.7%) had dislocated lens fragments. Most common findings on presentation included vitreous hemorrhage (n = 30 [70%]) and hyphema (n = 28 [64%]). Two eyes (4.7%) had a retinal detachment at presentation, and 10 (23%) developed a retinal detachment during follow-up visits. Anatomical success was observed in 11 eyes (92%) with a retinal detachment. Three eyes (7.0%) became phthisical or prephthisical, and 1 was enucleated for severe pain. No eyes developed endophthalmitis or sympathetic ophthalmia. This is the largest compilation of nail gun-related open-globe injury reported to date. Posterior segment complications, noted in the majority of cases, likely contributed to the overall guarded visual outcomes. Preventative measures for eye protection should be strictly followed while using nail guns.

  15. Modeling of composite beams and plates for static and dynamic analysis

    NASA Technical Reports Server (NTRS)

    Hodges, Dewey H.

    1992-01-01

    A rigorous theory and the corresponding computational algorithms were developed for through-the-thickness analysis of composite plates. This type of analysis is needed in order to find the elastic stiffness constants of a plate. Additionally, the analysis is used to post-process the resulting plate solution in order to find approximate three-dimensional displacement, strain, and stress distributions throughout the plate. It was decided that the variational-asymptotical method (VAM) would serve as a suitable framework in which to solve these types of problems. Work during this reporting period has progressed along two lines: (1) further evaluation of neo-classical plate theory (NCPT) as applied to shear-coupled laminates; and (2) continued modeling of plates with nonuniform thickness.

  16. Flexible intramedullary nailing for the treatment of unicameral bone cysts in long bones.

    PubMed

    Roposch, A; Saraph, V; Linhart, W E

    2000-10-01

    Unicameral bone cyst is characterized by its tenacity and risk of recurrence. Pathological fracture is common and is often the presenting symptom. The objective of the present study was to evaluate the results of flexible intramedullary nailing for the treatment of a unicameral bone cyst with or without a pathological fracture. Flexible intramedullary nailing for the treatment of a unicameral bone cyst was performed in thirty-two patients. Thirty of these patients presented with a pathological fracture; twenty-four were managed immediately with intramedullary nailing, and the other six had been managed conservatively at other clinics before they were referred to our department. The remaining two cysts were detected incidentally. The cyst was located in the humerus in twenty-one patients, in the femur in nine, and in the radius in two. The mean age of the patients at the time of surgery was 9.8 years, and the mean duration of follow-up was 53.7 months. Radiographic evaluation was performed according to the criteria of Capanna et al., and the cyst was classified as completely healed, healed with residual radiolucency (osteolysis), recurred, or having no response. The healing period ranged from three to 105 months. Fourteen cysts healed completely, and sixteen healed with residual radiolucent areas visible on radiographs. There was recurrence of two cysts that had healed with residual radiolucency. All of the cysts in the present study responded to treatment. A change of nails was necessary in nine patients, as the nails had become too short after bone growth. No major complications were observed. Flexible intramedullary nailing provides early stability, which allows early mobilization and thus obviates the need for a plaster cast and decreases the prevalence of the most common complication: a pathological fracture. This method of treatment also allows for an early return to normal activity.

  17. Equivalent plate modeling for conceptual design of aircraft wing structures

    NASA Technical Reports Server (NTRS)

    Giles, Gary L.

    1995-01-01

    This paper describes an analysis method that generates conceptual-level design data for aircraft wing structures. A key requirement is that this data must be produced in a timely manner so that is can be used effectively by multidisciplinary synthesis codes for performing systems studies. Such a capability is being developed by enhancing an equivalent plate structural analysis computer code to provide a more comprehensive, robust and user-friendly analysis tool. The paper focuses on recent enhancements to the Equivalent Laminated Plate Solution (ELAPS) analysis code that significantly expands the modeling capability and improves the accuracy of results. Modeling additions include use of out-of-plane plate segments for representing winglets and advanced wing concepts such as C-wings along with a new capability for modeling the internal rib and spar structure. The accuracy of calculated results is improved by including transverse shear effects in the formulation and by using multiple sets of assumed displacement functions in the analysis. Typical results are presented to demonstrate these new features. Example configurations include a C-wing transport aircraft, a representative fighter wing and a blended-wing-body transport. These applications are intended to demonstrate and quantify the benefits of using equivalent plate modeling of wing structures during conceptual design.

  18. The stability of a hip fracture determines the fatigue of an intramedullary nail.

    PubMed

    Eberle, S; Bauer, C; Gerber, C; von Oldenburg, G; Augat, P

    2010-01-01

    The purpose of this study was to address the question of how the stability of a proximal hip fracture determines the fatigue and failure mechanism of an intramedullary implant. To answer this question, mechanical experiments and finite element simulations with two different loading scenarios were conducted. The two load scenarios differed in the mechanical support of the fracture by an artificial bone sleeve, representing the femoral head and neck. The experiments confirmed that an intramedullary nail fails at a lower load in an unstable fracture situation in the proximal femur than in a stable fracture. The nails with an unstable support failed at a load 28 per cent lower than the nails with a stable support by the femoral neck. Hence, the mechanical support of a fracture is crucial to the fatigue failure of an implant. The simulation showed why the fatigue fracture of the nail starts at the aperture of the lag screw. It is the location of the highest von Mises stress, which is the failure criterion for ductile materials.

  19. Reduced dynamical model of the vibrations of a metal plate

    NASA Astrophysics Data System (ADS)

    Moreno, D.; Barrientos, Bernardino; Perez-Lopez, Carlos; Mendoza-Santoyo, Fernando; Guerrero, J. A.; Funes, M.

    2005-02-01

    The Proper Orthogonal Decomposition (POD) method is applied to the vibrations analysis of a metal plate. The data obtained from the metal plate under vibrations were measured with a laser vibrometer. The metal plate was subject to vibrations with an electrodynamical shaker in a range of frequencies from 100 to 5000 Hz. The deformation measurements were taken on a quarter of the plate in a rectangular grid of 7 x 8 points. The plate deformation measurements were used to calculate the eigenfunctions and the eigenvalues. It was found that a large fraction of the total energy of the deformation is contained within the first six POD modes. The essential features of the deformation are thus described by only the six first eigenfunctions. A reduced order model for the dynamical behavior is then constructed using Galerkin projection of the equation of motion for the vertical displacement of a plate.

  20. Theoretical model of the helium zone plate microscope

    NASA Astrophysics Data System (ADS)

    Salvador Palau, Adrià; Bracco, Gianangelo; Holst, Bodil

    2017-01-01

    Neutral helium microscopy is a new technique currently under development. Its advantages are the low energy, charge neutrality, and inertness of the helium atoms, a potential large depth of field, and the fact that at thermal energies the helium atoms do not penetrate into any solid material. This opens the possibility, among others, for the creation of an instrument that can measure surface topology on the nanoscale, even on surfaces with high aspect ratios. One of the most promising designs for helium microscopy is the zone plate microscope. It consists of a supersonic expansion helium beam collimated by an aperture (skimmer) focused by a Fresnel zone plate onto a sample. The resolution is determined by the focal spot size, which depends on the size of the skimmer, the optics of the system, and the velocity spread of the beam through the chromatic aberrations of the zone plate. An important factor for the optics of the zone plate is the width of the outermost zone, corresponding to the smallest opening in the zone plate. The width of the outermost zone is fabrication limited to around 10 nm with present-day state-of-the-art technology. Due to the high ionization potential of neutral helium atoms, it is difficult to build efficient helium detectors. Therefore, it is crucial to optimize the microscope design to maximize the intensity for a given resolution and width of the outermost zone. Here we present an optimization model for the helium zone plate microscope. Assuming constant resolution and width of the outermost zone, we are able to reduce the problem to a two-variable problem (zone plate radius and object distance) and we show that for a given beam temperature and pressure, there is always a single intensity maximum. We compare our model with the highest-resolution zone plate focusing images published and show that the intensity can be increased seven times. Reducing the width of the outermost zone to 10 nm leads to an increase in intensity of more than 8000

  1. Biomechanical evaluation of the risk of secondary fracture around short versus long cephalomedullary nails.

    PubMed

    Daner, William E; Owen, John R; Wayne, Jennifer S; Graves, Ryan B; Willis, Mark C

    2017-12-01

    For proximal femur fractures, long cephalomedullary nails (CMNs) are often selected to avoid a diaphyseal stress riser at the tip of a shorter nail. Secondary peri-implant fracture rates for long and short CMN have not been shown to differ clinically. This study biomechanically compares both CMN in a cadaveric model. Ten matched pairs of cadaveric femora with short or long CMN were axially loaded and internally rotated to failure. Resulting fractures involved distal interlocking screws of the short and long CMN. Energy and rotation to failure were significantly greater for short CMN. Torque at failure trended higher for short CMN but not significantly. No statistical difference was detected in stiffness of the short and long CMN. A greater risk of secondary fracture is not indicated for short versus long CMN under torsional stress. Short CMN may be suitable in the younger patient.

  2. Buyer beware: personnel selling nail guns know little about dangerous tools.

    PubMed

    Lipscomb, Hester J; Nolan, James; Patterson, Dennis; Fullen, Mark; Takacs, Brandon C; Pompeii, Lisa A

    2011-08-01

    Nail gun use is ubiquitous in wood frame construction. Accessibility and decreasing costs have extended associated occupational hazards to consumers. Compelling evidence documents decreased injury risk among trained users and those with tools with sequential triggers. To prevent inadvertent discharge of nails, this safer trigger requires the nose be depressed before the trigger is pulled to fire. The sequential trigger is not required by the Consumer Product Safety Commission (CPSC) or the Occupational Safety and Health Administration (OSHA) nor are there any guidelines for training. We collected data from personnel at 217 points of sale/rental of framing nail guns in four areas of the country. Sales personnel had little understanding of risks associated with use of framing nail guns. Individuals who had used the tool and those working in construction outlets were more likely to be knowledgeable; even so, less than half understood differences in trigger/actuation systems. Consumers, including contractors purchasing for workers, cannot count on receiving accurate information from sales personnel regarding risks associated with use of these tools. The attitudes and limited knowledge of some sales personnel regarding these potentially deadly tools likely contributes to a culture accepting of injury. The findings demonstrate how influences on the culture of construction are not limited to workers, employers, or the places construction gets done. Copyright © 2011 Wiley-Liss, Inc.

  3. Dosimetry during intramedullary nailing of the tibia.

    PubMed

    Kirousis, George; Delis, Harry; Megas, Panagiotis; Lambiris, Elias; Panayiotakis, George

    2009-10-01

    Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. The mean operation time was 101 (48-240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy x cm(2). The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique.

  4. Dosimetry during intramedullary nailing of the tibia

    PubMed Central

    2009-01-01

    Background Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. Patients and methods 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. Results The mean operation time was 101 (48–240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy·cm2. The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Interpretation Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique. PMID:19916691

  5. Computational Model for Impact-Resisting Critical Thickness of High-Speed Machine Outer Protective Plate

    NASA Astrophysics Data System (ADS)

    Wu, Huaying; Wang, Li Zhong; Wang, Yantao; Yuan, Xiaolei

    2018-05-01

    The blade or surface grinding blade of the hypervelocity grinding wheel may be damaged due to too high rotation rate of the spindle of the machine and then fly out. Its speed as a projectile may severely endanger the field persons. Critical thickness model of the protective plate of the high-speed machine is studied in this paper. For easy analysis, the shapes of the possible impact objects flying from the high-speed machine are simplified as sharp-nose model, ball-nose model and flat-nose model. Whose front ending shape to represent point, line and surface contacting. Impact analysis based on J-C model is performed for the low-carbon steel plate with different thicknesses in this paper. One critical thickness computational model for the protective plate of high-speed machine is established according to the damage characteristics of the thin plate to get relation among plate thickness and mass, shape and size and impact speed of impact object. The air cannon is used for impact test. The model accuracy is validated. This model can guide identification of the thickness of single-layer outer protective plate of a high-speed machine.

  6. Assessing the role of slab rheology in coupled plate-mantle convection models

    NASA Astrophysics Data System (ADS)

    Bello, Léa; Coltice, Nicolas; Tackley, Paul J.; Dietmar Müller, R.; Cannon, John

    2015-11-01

    Reconstructing the 3D structure of the Earth's mantle has been a challenge for geodynamicists for about 40 yr. Although numerical models and computational capabilities have substantially progressed, parameterizations used for modeling convection forced by plate motions are far from being Earth-like. Among the set of parameters, rheology is fundamental because it defines in a non-linear way the dynamics of slabs and plumes, and the organization of lithosphere deformation. In this study, we evaluate the role of the temperature dependence of viscosity (variations up to 6 orders of magnitude) and the importance of pseudo-plasticity on reconstructing slab evolution in 3D spherical models of convection driven by plate history models. Pseudo-plasticity, which produces plate-like behavior in convection models, allows a consistent coupling between imposed plate motions and global convection, which is not possible with temperature-dependent viscosity alone. Using test case models, we show that increasing temperature dependence of viscosity enhances vertical and lateral coherence of slabs, but leads to unrealistic slab morphologies for large viscosity contrasts. Introducing pseudo-plasticity partially solves this issue, producing thin laterally and vertically more continuous slabs, and flat subduction where trench retreat is fast. We evaluate the differences between convection reconstructions employing different viscosity laws to be very large, and similar to the differences between two models with the same rheology but using two different plate histories or initial conditions.

  7. Subsurface Characterization using Geophysical Seismic Refraction Survey for Slope Stabilization Design with Soil Nailing

    NASA Astrophysics Data System (ADS)

    Ashraf Mohamad Ismail, Mohd; Ng, Soon Min; Hazreek Zainal Abidin, Mohd; Madun, Aziman

    2018-04-01

    The application of geophysical seismic refraction for slope stabilization design using soil nailing method was demonstrated in this study. The potential weak layer of the study area is first identify prior to determining the appropriate length and location of the soil nail. A total of 7 seismic refraction survey lines were conducted at the study area with standard procedures. The refraction data were then analyzed by using the Pickwin and Plotrefa computer software package to obtain the seismic velocity profiles distribution. These results were correlated with the complementary borehole data to interpret the subsurface profile of the study area. It has been identified that layer 1 to 3 is the potential weak zone susceptible to slope failure. Hence, soil nails should be installed to transfer the tensile load from the less stable layer 3 to the more stable layer 4. The soil-nail interaction will provide a reinforcing action to the soil mass thereby increasing the stability of the slope.

  8. Factors Influencing Health Service Utilization Among Asian Immigrant Nail Salon Workers in the Greater New York City Area.

    PubMed

    Seo, Jin Young; Chao, Ying-Yu; Yeung, Ka Man; Strauss, Shiela M

    2018-06-23

    Most nail salon workers in the greater New York City area are Asian immigrant women. They are exposed daily to potentially toxic chemicals and hazards in their workplace, making them more vulnerable for possible health problems. The study's primary purpose was to identify factors influencing past year healthcare utilization among Asian immigrant women working in nail salons. A cross-sectional study was conducted based on a modification of Andersen's behavioral model of healthcare utilization in which 148 Korean and Chinese immigrant women currently working in nail salons were surveyed. The questionnaire included: (1) individual health determinants, (2) health service utilization in the past year, and (3) work environment, work-related health concerns, and work-related health problems. Descriptive statistics and multivariate logistic regression models assessed factors related to past year healthcare utilization. Women who had health insurance (p < .01), a usual source of care (p < .01), low educational attainment (p < .05), and more work-related health symptoms (p < .05) were more likely to visit a primary care provider. Women who had health insurance (p < .01), a usual source of care (p < .05), and low educational attainment (p < .05), were also more likely to visit a woman's health provider. Korean (rather than Chinese) women (p < .05) and women who perceived themselves to be in fair/poor health (p < .05) were more likely to see a traditional provider of Eastern medicine. Asian immigrant women who work in nail salons have workplace health and safety concerns. They generally use Western rather than traditional medicine, with different factors related to these two types of medicine.

  9. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model.

    PubMed

    Gajendran, Varun K; Szabo, Robert M; Myo, George K; Curtiss, Shane B

    2009-12-01

    Open or unstable metacarpal fractures frequently require open reduction and internal fixation. Locking plate technology has improved fixation of unstable fractures in certain settings. In this study, we hypothesized that there would be a difference in strength of fixation using double-row locking plates compared with single- and double-row non-locking plates in comminuted metacarpal fractures. We tested our hypothesis in a gap metacarpal fracture model simulating comminution using fourth-generation, biomechanical testing-grade composite sawbones. The metacarpals were divided into 6 groups of 15 bones each. Groups 1 and 4 were plated with a standard 6-hole, 2.3-mm plate in AO fashion. Groups 2 and 5 were plated with a 6-hole double-row 3-dimensional non-locking plate with bicortical screws aimed for convergence. Groups 3 and 6 were plated with a 6-hole double-row 3-dimensional locking plate with unicortical screws. The plated metacarpals were then tested to failure against cantilever apex dorsal bending (groups 1-3) and torsion (groups 4-6). The loads to failure in groups 1 to 3 were 198 +/- 18, 223 +/- 29, and 203 +/- 19 N, respectively. The torques to failure in groups 4 to 6 were 2,033 +/- 155, 3,190 +/- 235, and 3,161 +/- 268 N mm, respectively. Group 2 had the highest load to failure, whereas groups 5 and 6 shared the highest torques to failure (p < .05). Locking and non-locking double-row plates had equivalent bending and torsional stiffness, significantly higher than observed for the single-row non-locking plate. No other statistical differences were noted between groups. When subjected to the physiologically relevant forces of apex dorsal bending and torsion in a comminuted metacarpal fracture model, double-row 3-dimensional non-locking plates provided superior stability in bending and equivalent stability in torsion compared with double-row 3-dimensional locking plates, whereas single-row non-locking plates provided the least stability.

  10. Low concentrations of selenium and zinc in nails are associated with childhood asthma.

    PubMed

    Carneiro, Maria Fernanda Hornos; Rhoden, Claudia Ramos; Amantéa, Sérgio Luis; Barbosa, Fernando

    2011-12-01

    The purpose of this study was to investigate possible associations between Zn, Se, Cu, Mn, and Co concentrations in nails and asthma in a young population from a Southern Brazil city. Additionally, correlations between these chemical elements among asthmatic and non-asthmatic children were evaluated. Before nail collection (n = 165), children were asked to complete the International Study of Asthma and Allergies in Childhood questionnaire. The concentrations of trace elements were determined by inductively coupled plasma mass spectrometry. The chi-square test was used to evaluate the association between element concentrations in nails and the respiratory outcome. To evaluate correlations between the elements, we used the Spearman correlation test. For all tests, the significance level was set at 95% (P ≤ 0.05). Children included in the highest quartile of nail Se and Zn concentration presented a fivefold decrease in the prevalence ratio of asthma while children in the lowest Se range presented an almost 2.5-fold increase in the asthma prevalence ratio. There were weak to strong correlations between Cu vs. Zn, Cu vs. Co, Cu vs. Se, Zn vs. Se, Zn vs. Mn, and Mn vs. Co in both asthmatic and non-asthmatic children. Interestingly, non-asthmatics also presented correlations between Co vs. Se and Zn. Taken together, our results clearly demonstrated an association between concentrations of selenium and zinc and childhood asthma and the usefulness of nail as a noninvasive matrix to detect minerals imbalance in asthma patients.

  11. Density determination of nail polishes and paint chips using magnetic levitation

    NASA Astrophysics Data System (ADS)

    Huang, Peggy P.

    Trace evidence is often small, easily overlooked, and difficult to analyze. This study describes a nondestructive method to separate and accurately determine the density of trace evidence samples, specifically nail polish and paint chip using magnetic levitation (MagLev). By determining the levitation height of each sample in the MagLev device, the density of the sample is back extrapolated using a standard density bead linear regression line. The results show that MagLev distinguishes among eight clear nail polishes, including samples from the same manufacturer; separates select colored nail polishes from the same manufacturer; can determine the density range of household paint chips; and shows limited levitation for unknown paint chips. MagLev provides a simple, affordable, and nondestructive means of determining density. The addition of co-solutes to the paramagnetic solution to expand the density range may result in greater discriminatory power and separation and lead to further applications of this technique.

  12. Lasing in optimized two-dimensional iron-nail-shaped rod photonic crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwon, Soon-Yong; Moon, Seul-Ki; Yang, Jin-Kyu, E-mail: jinkyuyang@kongju.ac.kr

    2016-03-15

    We demonstrated lasing at the Γ-point band-edge (BE) modes in optimized two-dimensional iron-nail-shaped rod photonic crystals by optical pulse pumping at room temperature. As the radius of the rod increased quadratically toward the edge of the pattern, the quality factor of the Γ-point BE mode increased up to three times, and the modal volume decreased to 56% compared with the values of the original Γ-point BE mode because of the reduction of the optical loss in the horizontal direction. Single-mode lasing from an optimized iron-nail-shaped rod array with an InGaAsP multiple quantum well embedded in the nail heads was observedmore » at a low threshold pump power of 160 μW. Real-image-based numerical simulations showed that the lasing actions originated from the optimized Γ-point BE mode and agreed well with the measurement results, including the lasing polarization, wavelength, and near-field image.« less

  13. Using Global Plate Velocity Boundary Conditions for Embedded Regional Geodynamic Models

    NASA Astrophysics Data System (ADS)

    Taramon Gomez, Jorge; Morgan, Jason; Perez-Gussinye, Marta

    2015-04-01

    The treatment of far-field boundary conditions is one of the most poorly resolved issues for regional modeling of geodynamic processes. In viscous flow, the choice of far-field boundary conditions often strongly shapes the large-scale structure of a geosimulation. The mantle velocity field along the sidewalls and base of a modeling region is typically much more poorly known than the geometry of past global motions of the surface plates as constrained by global plate motion reconstructions. For regional rifting models it has become routine to apply highly simplified 'plate spreading' or 'uniform rifting' boundary conditions to a 3-D model that limits its ability to simulate the geodynamic evolution of a specific rifted margin. One way researchers are exploring the sensitivity of regional models to uncertain boundary conditions is to use a nested modeling approach in which a global model is used to determine a large-scale flow pattern that is imposed as a constraint along the boundaries of the region to be modeled. Here we explore the utility of a different approach that takes advantage of the ability of finite element models to use unstructured meshes than can embed much higher resolution sub-regions within a spherical global mesh. In our initial project to validate this approach, we create a global spherical mesh in which a higher resolution sub-region is created around the nascent South Atlantic Rifting Margin. Global Plate motion BCs and plate boundaries are applied for the time of the onset of rifting, continuing through several 10s of Ma of rifting. Thermal, compositional, and melt-related buoyancy forces are only non-zero within the high-resolution subregion, elsewhere, motions are constrained by surface plate-motion constraints. The total number of unknowns needed to solve an embedded regional model with this approach is less than 1/3 larger than that needed for a structured-mesh solution on a Cartesian or spherical cap sub-regional mesh. Here we illustrate

  14. Knee arthrodesis with an intramedullary nail: a retrospective study.

    PubMed

    De Vil, Jeroen; Almqvist, Karl Fredrik; Vanheeren, Philippe; Boone, Barbara; Verdonk, René

    2008-07-01

    A group of 19 patients who underwent knee arthrodesis with use of an intramedullary nail between 1996 and 2005, was studied. In the majority of patients knee arthrodesis was performed as a salvage procedure for the limb following an infected total knee arthroplasty. The outcome of the procedure was evaluated with radiographs, the SF-36 score and the Oxford 12-item knee score. The functional result of a successful arthrodesis was found to be comparable with that of a revised hinged total knee arthroplasty. Knee arthrodesis with an intramedullary nail allows weightbearing within 1 week and is accompanied by a high rate of pain relief. However, recurrence of infection is the most challenging problem.

  15. Efficacy and safety of Indigo naturalis extract in oil (Lindioil) in treating nail psoriasis: a randomized, observer-blind, vehicle-controlled trial.

    PubMed

    Lin, Yin-Ku; See, Lai-Chu; Huang, Yu-Huei; Chang, Ya-Ching; Tsou, Teng-Cheng; Lin, Tung-Yi; Lin, Na-Ling

    2014-06-15

    Treating nail psoriasis is notoriously difficult and lacks standardized therapeutic regimens. Indigo naturalis has been demonstrated to be safe and effective in treating skin psoriasis. This trial was conducted to evaluate the efficacy and safety of refined indigo naturalis extract in oil (Lindioil) in treating nail psoriasis. Thirty-one outpatients with symmetrically comparable psoriatic nails were enrolled. Lindioil (experimental group) or olive oil (control group) was applied topically to the same subjects' two bilaterally symmetrical psoriatic nails twice daily for the first 12 weeks and then subjects applied Lindioil to both hands for 12 additional weeks. Outcomes were measured using Nail Psoriasis Severity Index (NAPSI) for five nails on one hand and for the single most severely affected nail from either hand. The results show a reduction of NAPSI scores for the 12-week treatment for the Lindioil group (49.8% for one hand and 59.3% for single nail) was superior to the reduction in the scores for the control group (22.9%, 16.3%, respectively). There were no adverse events during the 24 weeks of treatment. This trial demonstrates that Lindioil is a novel, safe and effective therapy for treating nail psoriasis. Copyright © 2014 Elsevier GmbH. All rights reserved.

  16. Fatigue strength of common tibial intramedullary nail distal locking screws

    PubMed Central

    Griffin, Lanny V; Harris, Robert M; Zubak, Joseph J

    2009-01-01

    Background Premature failure of either the nail and/or locking screws with unstable fracture patterns may lead to angulation, shortening, malunion, and IM nail migration. Up to thirty percent of all unreamed nail locking screws can break after initial weight bearing is allowed at 8–10 weeks if union has not occurred. The primary problem this presents is hardware removal during revision surgery. The purposes of our study was to evaluate the relative fatigue resistance of distal locking screws and bolts from representative manufacturers of tibial IM nail systems, and develop a relative risk assessment of screws and materials used. Evaluations included quantitative and qualitative measures of the relative performance of these screws. Methods Fatigue tests were conducted to simulate a comminuted fracture that was treated by IM nailing assuming that all load was carried by the screws. Each screw type was tested ten times in a single screw configuration. One screw type was tested an additional ten times in a two-screw parallel configuration. Fatigue tests were performed using a servohydraulic materials testing system and custom fixturing that simulated screws placed in the distal region of an appropriately sized tibial IM nail. Fatigue loads were estimated based on a seventy-five kilogram individual at full weight bearing. The test duration was one million cycles (roughly one year), or screw fracture, whichever occurred first. Failure analysis of a representative sample of titanium alloy and stainless steel screws included scanning electron microscopy (SEM) and quantitative metallography. Results The average fatigue life of a single screw with a diameter of 4.0 mm was 1200 cycles, which would correspond roughly to half a day of full weight bearing. Single screws with a diameter of 4.5 mm or larger have approximately a 50 percent probability of withstanding a week of weight bearing, whereas a single 5.0 mm diameter screw has greater than 90 percent probability of

  17. Static and Vibration Analyses of General Wing Structures Using Equivalent Plate Models

    NASA Technical Reports Server (NTRS)

    Kapania, Rakesh K.; Liu, Youhua

    1999-01-01

    An efficient method, using equivalent plate model, is developed for studying the static and vibration analyses of general built-up wing structures composed of skins, spars, and ribs. The model includes the transverse shear effects by treating the built-up wing as a plate following the Reissner-Mindlin theory, the so-called First-order Shear Deformation Theory (FSDT). The Ritz method is used with the Legendre polynomials being employed as the trial functions. This is in contrast to previous equivalent plate model methods which have used simple polynomials, known to be prone to numerical ill-conditioning, as the trial functions. The present developments are evaluated by comparing the results with those obtained using MSC/NASTRAN, for a set of examples. These examples are: (i) free-vibration analysis of a clamped trapezoidal plate with (a) uniform thickness, and (b) non-uniform thickness varying as an airfoil, (ii) free-vibration and static analyses (including skin stress distribution) of a general built-up wing, and (iii) free-vibration and static analyses of a swept-back box wing. The results obtained by the present equivalent plate model are in good agreement with those obtained by the finite element method.

  18. A novel method for assessing chronic cortisol concentrations in dogs using the nail as a source.

    PubMed

    Mack, Z; Fokidis, H B

    2017-04-01

    Cortisol, a glucocorticoid secreted in response to stress, is used to assess adrenal function and mental health in clinical settings. Current methods assess cortisol sources that reflect short-term secretion that can vary with current stress state. Here, we present a novel method for the extraction and quantification of cortisol from the dog nail using solid phase extraction coupled to enzyme-linked immunosorbent assay. Validation experiments demonstrated accuracy (r = 0.836, P < 0.001) precision (15.1% coefficients of variation), and repeatability (14.4% coefficients of variation) with this method. Furthermore, nail cortisol concentrations were positively correlated to an established hair cortisol method (r = 0.736, P < 0.001). Nail cortisol concentrations did not differ with dog sex, breed, age, or weights; however, sample size limitations may preclude statistical significance. Nail cortisol may provide information on cortisol secretion integrated over the time corresponding to nail growth and may be useful as a tool for diagnosing stress and adrenal disorders in dogs. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. RESIDENTIAL BUILDING STAKEHOLDERS’ ATTITUDES AND BELIEFS REGARDING NAIL GUN INJURY RISKS AND PREVENTION

    PubMed Central

    ALBERS, JAMES T.; HUDOCK, STEPHEN D.; LOWE, BRIAN D.

    2015-01-01

    Pneumatic nail guns are ubiquitous at residential construction sites across the United States. These tools are noted for the traumatic injuries that can occur from their operation. Different trigger mechanisms on these tools are associated with different levels of risk. Residential building subcontractors and workers, both native-born and immigrant, were brought together in focus groups to discuss their attitudes and beliefs regarding risk factors for nail gun injury as well as barriers to the adoption of safer technology. Participants’ comments are organized first by influences on traumatic injury occurrence or prevention and later by sociotechnical system category. Participants attributed influences on injury risk to personal and external causation factors in all sociotechnical system categories; however, participants more frequently described influences on injury prevention as related to workers’ behaviors, rather than to external factors. A discussion of these influences with respect to attribution theory and sociotechnical models of injury causation is presented. PMID:24704813

  20. Minimizing the complications of intramedullary nailing for distal third tibial shaft and metaphyseal fractures

    PubMed Central

    Yaligod, Vishwanath; Rudrappa, Girish H.; Nagendra, Srinivas; Shivanna, Umesh M.

    2013-01-01

    Background The complications of intramedullary nailing of distal third tibial shaft and metaphyseal fractures have a direct impact on ankle and hind foot function. Methods We retrospectively evaluated 28 patients. Unreamed nail was negotiated across the well reduced fracture till subchondral bone and fixed with 2 to 3 distal locking screws in different planes. Results Fracture union rate was 85%. Three out of 28 patients had malalignment. Mean ankle, hindfoot functional score was 85. Conclusion Complications can be minimized by impacting the unreamed nail till the subchondral bone while maintaining the fracture well reduced and by using multiple distal locking screws in different planes. PMID:24719527

  1. 77 FR 24462 - Certain Steel Nails From the People's Republic of China: Amended Final Results of the Second...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-24

    ... steel nails: (1) Non-collated (i.e., hand-driven or bulk), two-piece steel nails having plastic or steel...-collated (i.e., hand-driven or bulk), steel nails having a bright or galvanized finish, a smooth, barbed or... actual head diameter of 0.3375'' to 0.500'', inclusive; and (4) Non-collated (i.e., hand-driven or bulk...

  2. [Influence of nail polish on pulse oximeter readings of oxygen saturation: a systematic review].

    PubMed

    Ballesteros-Peña, Sendoa; Fernández-Aedo, Irrintzi; Picón, Artzai; Lorrio-Palomino, Sergio

    2015-10-01

    Nail polish has traditionally been assumed to absorb light emitted by pulse oximeters and to interfere with the detection and measurement of oxygenated hemoglobin. In a systematic review of the literature we aimed to assess the influence of nail polish on the measurement of oxygen saturation by pulse oximetry (SpO2). A search protocol for online databases (MEDLINE, Embase, Web of Science, Scopus, Cumulative Index to Nursing and Allied Health Literature, and IBECS [the Spanish health sciences index]) was established to find clinical trials or observational studies published between 1999 and February 2014. Twelve nonrandomized clinical trials were found. Ten were in healthy volunteers. One of the remaining 2 studies was in critical patients undergoing mechanical ventilation, and the other was in patients with stable chronic obstructive pulmonary disease. One study recreated the low oxygen level of high altitudes, while the others were done in normal atmospheric conditions. Differences between pulse oximeters and type of nail polish were found. Nail polish was associated with a statistically significant decrease in SpO2 for at least 1 color in all but 2 studies. However, the differences were within the standard error (±2.0%) of the pulse oximeters used. The authors of the studies all concluded that although nail polish might change SpO2 readings significantly, the variations are not clinically significant.

  3. Evaluation of drug incorporation into hair segments and nails by enantiomeric analysis following controlled single MDMA intakes.

    PubMed

    Madry, Milena M; Steuer, Andrea E; Hysek, Cédric M; Liechti, Matthias E; Baumgartner, Markus R; Kraemer, Thomas

    2016-01-01

    Incorporation rates of the enantiomers of 3,4-methylenedioxymethamphetamine (MDMA) and its metabolite 3,4-methylenedioxyamphetamine (MDA) into hair and nails were investigated after controlled administration. Fifteen subjects without MDMA use received two doses of 125 mg of MDMA. Hair, nail scrapings, and nail clippings were collected 9-77 days after the last administration (median 20 days). Hair samples were analyzed in segments of 1- to 2-cm length. After chiral derivatization with N-(2,4-dinitro-5-fluorophenyl)-L-valinamide, MDMA and MDA diastereomers were analyzed by liquid chromatography-tandem mass spectrometry. Highest concentrations in hair segments corresponded to the time of MDMA intake. They ranged from 101 to 3200 pg/mg and 71 to 860 pg/mg for R- and S-MDMA, and from 3.2 to 116 pg/mg and 4.4 to 108 pg/mg for R- and S-MDA, respectively. MDMA and MDA concentrations in nail scrapings and clippings were significantly lower than in hair samples. There was no significant difference between enantiomeric ratios of R/S-MDMA and R/S-MDA in hair and nail samples (medians 2.2-2.4 for MDMA and 0.85-0.95 for MDA). Metabolite ratios of MDA to MDMA were in the same range in hair and nail samples (medians 0.044-0.055). Our study demonstrates that administration of two representative doses of MDMA was detected in the hair segments corresponding to the time of intake based on average hair growth rates. MDMA was detected in all nail samples regardless of time passed after intake. Comparable R/S ratios in hair and nail samples may indicate that incorporation mechanisms into both matrices are comparable.

  4. Biomechanical properties of a structurally optimized carbon-fibre/epoxy intramedullary nail for femoral shaft fracture fixation.

    PubMed

    Samiezadeh, Saeid; Fawaz, Zouheir; Bougherara, Habiba

    2016-03-01

    Intramedullary nails are the golden treatment option for diaphyseal fractures. However, their high stiffness can shield the surrounding bone from the natural physiologic load resulting in subsequent bone loss. Their stiff structure can also delay union by reducing compressive loads at the fracture site, thereby inhibiting secondary bone healing. Composite intramedullary nails have recently been introduced to address these drawbacks. The purpose of this study is to evaluate the mechanical properties of a previously developed composite IM nail made of carbon-fibre/epoxy whose structure was optimized based on fracture healing requirements using the selective stress shielding approach. Following manufacturing, the cross-section of the composite nail was examined under an optical microscope to find the porosity of the structure. Mechanical properties of the proposed composite intramedullary nail were determined using standard tension, compression, bending, and torsion tests. The failed specimens were then examined to obtain the modes of failure. The material showed high strength in tension (403.9±7.8MPa), compression (316.9±10.9MPa), bending (405.3±8.1MPa), and torsion (328.5±7.3MPa). Comparing the flexural modulus (41.1±0.9GPa) with the compressive modulus (10.0±0.2GPa) yielded that the material was significantly more flexible in compression than in bending. This customized flexibility along with the high torsional stiffness of the nail (70.7±2.0Nm(2)) has made it ideal as a fracture fixation device since this unique structure can stabilize the fracture while allowing for compression of fracture ends. Negligible moisture absorption (~0.5%) and low porosity of the laminate structure (< 3%) are other advantages of the proposed structure. The findings suggested that the carbon-fibre/epoxy intramedullary nail is flexible axially while being relatively rigid in bending and torsion and is strong enough in all types of physiologic loading, making it a potential

  5. 77 FR 17029 - Certain Steel Nails From the United Arab Emirates: Final Determination of Sales at Less Than Fair...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-23

    ... coils using materials such as plastic, paper, or wire. Certain steel nails subject to this investigation... plastic or steel washers (``caps'') already assembled to the nail, having a bright or galvanized finish, a... Initiation Notice,\\2\\ by removing the language referring to the packaging characteristics of certain nails...

  6. Three-dimensional finite element analysis and comparison of a new intramedullary fixation with interlocking intramedullary nail.

    PubMed

    Liu, Chang-cheng; Xing, Wen-zhao; Zhang, Ya-xing; Pan, Zheng-hua; Feng, Wen-ling

    2015-03-01

    This study was set to introduce a new intramedullary fixation, explore its biomechanical properties, and provide guidance for further biomechanical experiments. With the help of CT scans and finite element modeling software, finite element model was established for a new intramedullary fixation and intramedullary nailing of femoral shaft fractures in a volunteer adult. By finite element analysis software ANSYS 10.0, we conducted 235-2,100 N axial load, 200-1,000 N bending loads and 2-15 Nm torsional loading, respectively, and analyzed maximum stress distribution, size, and displacement of the fracture fragments of the femur and intramedullary nail. During the loading process, the maximum stress of our new intramedullary fixation were within the normal range, and the displacement of the fracture fragments was less than 1 mm. Our new intramedullary fixation exhibited mechanical reliability and unique advantages of anti-rotation, which provides effective supports during fracture recovery.

  7. Mathematical modeling of a dynamic thin plate deformation in acoustoelasticity problems

    NASA Astrophysics Data System (ADS)

    Badriev, I. B.; Paimuhin, V. N.

    2018-01-01

    The coupled problem of planar acoustic wave propagation through a composite plate covered with a second damping layer with a large logarithmic decrement of oscillations is formulated. The aerohydrodynamic interaction of a plate with external acoustic environment is described by three-dimensional wave equations and the mechanical behavior of a two-layer plate by the classical Kirchhoff-Love model. An exact analytic solution of the problem is found for the case of hinged support of the edges of a plate. On the basis of this, the parameters of the covering damping layer were found, under which it is possible to achieve a practically complete damping of the plate vibration under resonant modes of its acoustic loading.

  8. Ankle salvage surgery with autologous circular pillar fibula augmentation and intramedullary hindfoot nail.

    PubMed

    Paul, Jochen; Barg, Alexej; Horisberger, Monika; Herrera, Mario; Henninger, Heath B; Valderrabano, Victor

    2014-01-01

    Tibiotalocalcaneal arthrodesis with an intramedullary hindfoot nail is an established procedure for fusion of the ankle and subtalar joints. In cases involving ankle bone loss, such as in failed total ankle replacement, it can be difficult to salvage with sufficient bone restoration stability and a physiologic leg length and avoiding below the knee amputation. In addition to the alternatives of using a structural allograft or metal bone substitution, we describe the use of autologous ipsilateral circular pillar fibula augmentation in tibiotalocalcaneal retrograde nail arthrodesis combined with a ventral (anterior) plate in a prospective series of 6 consecutive cases with a mean follow-up duration of 26 ± 9.95 (range 12 to 34) months. The 6 patients (3 female and 3 male), with a mean age of 55 ± 13.89 (range 38 to 73) years were treated with revision surgery of the ankle (1 after talectomy, 5 [83.33%] after failed ankle replacement). The visual analog scale for pain and the American Orthopaedic Foot and Ankle Society hindfoot score were used to assess functional outcome, and radiographs and computed tomography scans were used to determine the presence of fusion. All patients improved clinically from pre- to postoperatively in regard to the mean pain visual analog scale score (from 7.5 to 2.0) and American Orthopaedic Foot and Ankle Society hindfoot score (from 29 to 65 points, of an 86-point maximum for fused joints). Radiologically, no loss in the reduction or misalignment of the hindfoot was detected, and all cases fused solid. One patient (16.67%) required hardware removal. The fixation construct provided good clinical and radiologic outcomes, and we recommend it as an alternative to structural allografts or metallic bone grafts for revision ankle surgery with severe bone loss. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Achieving interlocking nails without using an image intensifier

    PubMed Central

    Ogunlusi, Johnson D.; Ine, Henry R.

    2006-01-01

    Interlocking nails are commonly performed using an image intensifier. These are expensive and are not readily available in most resource-poor countries of the world. The aim of this study was to achieve interlocking nailing without the use of an image intensifier. This is a prospective descriptive analysis of 40 consecutive cases seen with shaft fractures of the humerus, femur, and tibia. Fracture fixation was done using Surgical Implant Generation Network (SIGN) nails. Forty limbs in 34 patients were studied. There were 12 females and 22 males, giving a ratio of 1:2. The mean age (years) was 35.75±13.16 and the range was 17–70 years. The studied bones were: humerus 10%, femur 65%, and tibia 25%. The fracture lines were: transverse 40%, oblique 15%, and communited 45%. Fracture grades were: closed 90%, grade I, 5%, grade II, 2.5%, and grade IIIA, 2.5%. Surgical approaches were: antegrade 62.5% and retrograde 37.5%. Indications for fixation were: recent fracture 92.5%, non-union 5%, and malunion 3%. Methods of reductions were: open 85% and closed 15%. The mean follow-up period (years) was 1.50±0.78. The union time averaged 3 months. Complication was mainly screw loosening due to severe osteoporoses in one case. It is, therefore, concluded that, with the aid of external jigs and slot finders, interlocking can be achieved without an image intensifier. PMID:17039384

  10. Trochanteric entry femoral nails yield better femoral version and lower revision rates-A large cohort multivariate regression analysis.

    PubMed

    Yoon, Richard S; Gage, Mark J; Galos, David K; Donegan, Derek J; Liporace, Frank A

    2017-06-01

    Intramedullary nailing (IMN) has become the standard of care for the treatment of most femoral shaft fractures. Different IMN options include trochanteric and piriformis entry as well as retrograde nails, which may result in varying degrees of femoral rotation. The objective of this study was to analyze postoperative femoral version between three types of nails and to delineate any significant differences in femoral version (DFV) and revision rates. Over a 10-year period, 417 patients underwent IMN of a diaphyseal femur fracture (AO/OTA 32A-C). Of these patients, 316 met inclusion criteria and obtained postoperative computed tomography (CT) scanograms to calculate femoral version and were thus included in the study. In this study, our main outcome measure was the difference in femoral version (DFV) between the uninjured limb and the injured limb. The effect of the following variables on DFV and revision rates were determined via univariate, multivariate, and ordinal regression analyses: gender, age, BMI, ethnicity, mechanism of injury, operative side, open fracture, and table type/position. Statistical significance was set at p<0.05. A total of 316 patients were included. Piriformis entry nails made up the majority (n=141), followed by retrograde (n=108), then trochanteric entry nails (n=67). Univariate regression analysis revealed that a lower BMI was significantly associated with a lower DFV (p=0.006). Controlling for possible covariables, multivariate analysis yielded a significantly lower DFV for trochanteric entry nails than piriformis or retrograde nails (7.9±6.10 vs. 9.5±7.4 vs. 9.4±7.8°, p<0.05). Using revision as an endpoint, trochanteric entry nails also had a significantly lower revision rate, even when controlling for all other variables (p<0.05). Comparative, objective comparisons between DFV between different nails based on entry point revealed that trochanteric nails had a significantly lower DFV and a lower revision rate, even after regression

  11. Treatment of pediatric femoral shaft fractures by stainless steel and titanium elastic nail system: A randomized comparative trial.

    PubMed

    Gyaneshwar, Tank; Nitesh, Rustagi; Sagar, Tomar; Pranav, Kothiyal; Rustagi, Nitesh

    2016-08-01

    Literature suggests that the lower modulus of elasticity of titanium makes it ideal for use in children compared with stainless steel. Better fracture stability was observed in association with titanium nails on torsional and axial compression testing. However, stainless steel nails are stiffer than titanium counterparts, which may provide a rigid construct when fixing paediatric femoral shaft fractures. Complications have been observed more frequently by various researchers when titanium nails are used for fracture fixation in patients with increasing age or weight. The concept of this study was to compare the functional outcome after internal fixation with titanium elastic nail system and stainless steel elastic nail system in paediatric femoral shaft fractures. The study was conducted on 34 patients admitted in the department of orthopaedics, LLRM Medical College & SVBP Hospital, Meerut, India from January 2013 to August 2014. We included patients aged 5-12 years with fracture of the femoral shaft, excluding compound fractures, pathological fractures and other lower limb fractures. Patients were treated by titanium (n=17) or stainless steel (n=17) elastic nail system and followed up for one year. The clinical parameters like range of motion at hip and knee joints, time to full weight bearing on the operated limb and radiological parameters like time to union were compared between two groups. A special note was made of intra- and post-operative complications. Functional outcomes were analysed according to Flynn criteria. Based on the Flynn criteria, 59% of patients had excellent results, 41% had satisfactory results, and no one showed poor results. There was no clinically significant difference between the two groups with respect to time to union and full weight bearing. But the incidence of puncture of the opposite cortex while inserting the nail and trying to advance it through the diaphysis during operation is greatly different. Only one such case was observed

  12. Intramedullary osteosynthesis versus plate osteosynthesis in subtrochanteric fractures.

    PubMed

    Burnei, C; Popescu, Gh; Barbu, D; Capraru, F

    2011-11-14

    Due to an ever-aging population and a growing prevalence of osteoporosis and motor vehicle accidents, the number of subtrochanteric fractures is increasing worldwide. The choice of the appropriate implant continues to be critical for fixation of unstable hip fractures. The subtrochanteric region has certain anatomical and biomechanical features that can make fractures in this region difficult to treat. The preferred type of device is a matter of debate. Increased understandings of biomechanical characteristics of the hip and improvement of the implant materials have reduced the incidence of complications. The surgeons choose between the two methods according to Seinsheimer's classification and also to their personal preferences. As a general principle, the open reduction and internal fixation were performed in stable fractures, and the closed reduction and internal fixation were performed in unstable fractures. The advantages of intramedullary nailing consist in a small skin incision, lower operating times, preservation of fracture hematoma and the possibility of early weight bearing. The disadvantages consist in a difficult closed reduction due to important muscular forces, although the nail can be used as a reduction instrument, and higher implant cost. In open reduction internal fixation techniques, the advantage is represented by anatomical reduction which, in our opinion, is not necessary. The disadvantages are represented by: higher operating time, demanding surgery, large devascularization, higher infection rates, late weight bearing, medial instability, refracture after plate removal and inesthetic approach.

  13. Intramedullary osteosynthesis versus plate osteosynthesis in subtrochanteric fractures

    PubMed Central

    Burnei, C; Popescu, Gh; Barbu, D; Capraru, F

    2011-01-01

    Due to an ever-aging population and a growing prevalence of osteoporosis and motor vehicle accidents, the number of subtrochanteric fractures is increasing worldwide. The choice of the appropriate implant continues to be critical for fixation of unstable hip fractures. The subtrochanteric region has certain anatomical and biomechanical features that can make fractures in this region difficult to treat. The preferred type of device is a matter of debate. Increased understandings of biomechanical characteristics of the hip and improvement of the implant materials have reduced the incidence of complications. The surgeons choose between the two methods according to Seinsheimer's classification and also to their personal preferences. As a general principle, the open reduction and internal fixation were performed in stable fractures, and the closed reduction and internal fixation were performed in unstable fractures. The advantages of intramedullary nailing consist in a small skin incision, lower operating times, preservation of fracture hematoma and the possibility of early weight bearing. The disadvantages consist in a difficult closed reduction due to important muscular forces, although the nail can be used as a reduction instrument, and higher implant cost. In open reduction internal fixation techniques, the advantage is represented by anatomical reduction which, in our opinion, is not necessary. The disadvantages are represented by: higher operating time, demanding surgery, large devascularization, higher infection rates, late weight bearing, medial instability, refracture after plate removal and inesthetic approach. PMID:22514563

  14. Global isostatic geoid anomalies for plate and boundary layer models of the lithosphere

    NASA Technical Reports Server (NTRS)

    Hager, B. H.

    1981-01-01

    Commonly used one dimensional geoid models predict that the isostatic geoid anomaly over old ocean basins for the boundary layer thermal model of the lithosphere is a factor of two greater than that for the plate model. Calculations presented, using the spherical analogues of the plate and boundary layer thermal models, show that for the actual global distribution of plate ages, one dimensional models are not accurate and a spherical, fully three dimensional treatment is necessary. The maximum difference in geoid heights predicted for the two models is only about two meters. The thermal structure of old lithosphere is unlikely to be resolvable using global geoid anomalies. Stripping the effects of plate aging and a hypothetical uniform, 35 km, isostatically-compensated continental crust from the observed geoid emphasizes that the largest-amplitude geoid anomaly is the geoid low of almost 120 m over West Antarctica, a factor of two greater than the low of 60 m over Ceylon.

  15. Functional outcome following tibio-talar-calcaneal nailing for unstable osteoporotic ankle fractures.

    PubMed

    Jonas, S C; Young, A F; Curwen, C H; McCann, P A

    2013-07-01

    Fragility fractures of the ankle are increasing in incidence. Such fractures typically occur from low-energy injuries but lead to disproportionately high levels of morbidity. Ankle fractures in this age group are managed conservatively in plaster or by open reduction and internal fixation. Both modalities have shown high rates of failure in terms of delayed union or mal-union together with perioperative complications such as implant failure and wound breakdown. The optimal treatment of these patients remains controversial. We aimed to review the functional outcome of patients with ankle fragility fractures primarily managed using a tibio-talar-calcaneal nail (TTC). We retrospectively reviewed 31 consecutive patients primarily managed with a TCC nail for osteoporotic fragility fractures about the ankle. Data were collected via case notes, radiographic reviews and by clinical reviews at the outpatient clinic or a telephone follow-up. Information regarding patient characteristics, indication for operation, Arbeitsgemeinschaft für Osteosynthesefragen (AO) fracture classification, operative and postoperative complications, time to radiographic union and current clinical state including Olerud and Molander scores were recorded (as a measure of ankle function). Nine of 31 patients had died by the time of follow-up. Mean preoperative and postoperative Olerud and Molander scores were 56 and 45, respectively. There were no postoperative wound complications. Twenty-nine of 31 patients returned to the same level of mobility as pre-injury. There were three peri-prosthetic fractures managed successfully with nail removal and replacement or plaster cast. There were two nail failures, both in patients who mobilised using only a stick, which were managed by nail removal. Ten of 31 patients were not followed up radiographically due to either infirmity or death. Thirteen of 21 followed up radiographically had evidence of union and 8/21 had none. None, however, had clinical evidence

  16. Superfund Record of Decision (EPA Region 4): Independent Nail, Beaufort, Beaufort County, South Carolina (second remedial action), August 1988. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1988-03-08

    The Independent Nail site, occupying 24.6 acres, is located near the town of Beaufort, South Carolina. The Black and Johnson Company, previous owners of the site, manufactured metallic screws and fasteners. As part of the manufacturing process, the company discharged approximately 33,000 gallons per day of plating wastewater into an unlined infiltration lagoon. The discharge rate may have been as high as 75,000 gallons per day. The lagoon was in use from approximately 1969 to 1980. The South Carolina Department of Health and Environmental Control reported that waste water contained some organic cleaning solvents and metals. The primary contaminants ofmore » concern include chromium, zinc and cyanide.« less

  17. A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model.

    PubMed

    Kenzig, Allison R; Butler, James R; Priddy, Lauren B; Lacy, Kristen R; Elder, Steven H

    2017-07-13

    Fracture of the ilium is common orthopedic injury that often requires surgical stabilization in canine patients. Of the various methods of surgical stabilization available, application of a lateral bone plate to the ilium is the most common method of fixation. Many plating options are available, each having its own advantages and disadvantages. The purpose of this study was to evaluate the biomechanical properties of a 3.5 mm String-of-Pearls™ plate and a 3.5 mm dynamic compression plate in a cadaveric canine ilial fracture model. Hemipelves were tested in cantilever bending to failure and construct stiffness, yield load, displacement at yield, ultimate load, and mode of failure were compared. The mean stiffness of dynamic compression plate (116 ± 47 N/mm) and String-of-Pearls™ plate (107 ± 18 N/mm) constructs, mean yield load of dynamic compression plate (793 ± 333 N) and String-of-Pearls™ plate (860 ± 207 N) constructs, mean displacement at yield of dynamic compression plate (8.6 ± 3.0 mm) and String-of-Pearls™ plate (10.2 ± 2.8 mm) constructs, and ultimate load at failure of dynamic compression plate (936 ± 320 N) and String-of-Pearls™ plate (939 ± 191 N) constructs were not significantly different. No differences were found between constructs with respect to mode of failure. No significant biomechanical differences were found between String-of-Pearls™ plate and dynamic compression plate constructs in this simplified cadaveric canine ilial fracture model.

  18. Hair and Nail Changes During Long-term Therapy With Ibrutinib for Chronic Lymphocytic Leukemia.

    PubMed

    Bitar, Carole; Farooqui, Mohammed Z H; Valdez, Janet; Saba, Nakhle S; Soto, Susan; Bray, Amanda; Marti, Gerald; Wiestner, Adrian; Cowen, Edward W

    2016-06-01

    Ibrutinib, a Bruton tyrosine kinase inhibitor, is a new targeted agent approved by the US Food and Drug Administration for the treatment of chronic lymphocytic leukemia (CLL), mantle cell lymphoma, and Waldenström macroglobulinemia. Ibrutinib is overall well tolerated but long-term treatment is required until disease progression or intolerable toxic effects occur. Little is known regarding its cutaneous adverse effects. To describe the hair and nail manifestations associated with the long-term use of ibrutinib for the treatment of CLL. Prospective study of 66 patients with CLL enrolled in a single-arm phase 2 clinical trial of ibrutinib for CLL between March 2014 and October 2015 at the National Institutes of Health. The primary outcome, nail and hair changes associated with ibrutinib therapy, was assessed by an 11-question survey. In addition, the severity of nail changes was determined from a 0 to 3 rating scale for both onychoschizia and onychorrhexis. Among 66 patients (43 men and 23 women with ages ranging from 55 to 85 years), 44 (67%) reported brittle fingernails at a median of 6.5 (95% CI, 6-12) months after starting ibrutinib therapy. Fifteen patients (23%) developed brittle toenails after a median of 9 (95% CI, 6-15) months of ibrutinib therapy. Textural hair changes were reported in 17 patients (26%), at a median of 9 (95% CI, 6-12) months of ibrutinib treatment. Hair and nail abnormalities are commonly associated with ibrutinib and appear several months after initiating therapy. Ibrutinib inhibits Bruton tyrosine kinase by covalently binding to cysteine 481. Whether ibrutinib affects the hair and nails by binding and altering cysteine-rich proteins of hair and nails or by means of another mechanism remains unknown. clinicaltrials.gov Identifier: NCT01500733.

  19. A new kinematic model for the Mesozoic evolution of the Iberia plate

    NASA Astrophysics Data System (ADS)

    Nirrengarten, Michael; Manatschal, Gianreto; Tugend, Julie; Kusznir, Nick; Sauter, Daniel

    2017-04-01

    During the Mesozoic Iberia was progressively surrounded by rift systems leading to its transient individualization as a tectonic plate. The kinematic evolution of Iberia prior to oceanic magnetic anomaly C34 ( 83 Ma) is controversial. To date, no kinematic models accounts for the Late Aptian to Albian hyper-extended rift phase observed in the Pyrenees. Consistent isochronal features, such as oceanic magnetic anomalies, representing the backbones of oceanic plate reconstructions are lacking. The only potential candidate, the J-anomaly, located offshore Iberia and Newfoundland has recently been re-interpreted as resulting from polyphased and polygenic magmatic events and does not provide a useful constraint. We use a new reconstruction approach that integrates the spatio-temporal evolution of adjacent hyper-extended rift domains systems to investigate Iberia plate motion during the separation of the super-continent Pangea. The plate modeling is based on careful mapping and restoration of the rift domains with key rift events dated within the study area. The main outcomes of this new model are as follows: 1) A full-fit of the southern North Atlantic 2) Extension on the southern and eastern boundary of Iberia related to the opening of the Central Atlantic 3) Segmentation of the Iberia-Newfoundland rift system by fracture zones prior to a V-shape propagation of mantle exhumation and seafloor spreading 4) No Aptian subduction in the Pyrenean domain and a limited rotation of the Iberia plate 5) The partitioning of deformation between different micro-blocks along the Iberian-Eurasian boundary enabling Late Aptian to Albian extension in the Pyrenees The resulting plate kinematic model for Iberia differs from previous ones on three main points: it does not make use of the J magnetic anomaly because the J anomlay is neither an isochron or a COB marker; the deformation along the Iberian-Eurasian boundary is partitioned between distinct rift systems; and it incorporates

  20. TEM characterization of the fine scale microstructure of a Roman ferrous nail

    NASA Astrophysics Data System (ADS)

    Douin, J.; Henry, O.; Dabosi, F.; Sciau, P.

    2010-07-01

    This paper describes the microstructure of a Roman ferrous nail through its observation by transmission electron microscopy. The morphologies of pearlitic colonies and ferritic grains are detailed and the relationship between pearlitic colonies and ferrite in Roman nails is explicitly demonstrated for the first time. Observations also confirm the presence of dislocations in ferritic grains and attest to the existence of very small carbide precipitates that have not been pointed out previously in standard archaeometric studies.

  1. Case reports: A subtrochanteric femur fracture with long intramedullary femorotibial nail for knee arthrodesis.

    PubMed

    Torga-Spak, Roger; Gugala, Zbigniew; Lindsey, Ronald W

    2006-03-01

    We present a case report of a patient who had a transverse subtrochanteric femur fracture develop 2 months after uneventful placement of a long femorotibial intramedullary nail for knee arthrodesis. To date, diaphyseal fracture of a femur already stabilized with an intramedullary nail has not been reported. The possible etiology for this unusual complication is discussed.

  2. [Clinical study of full-thickness skin graft for reconstruction of completely defect nail unit].

    PubMed

    Li, Wen-jun; Li, Chun; Zhu, Jin; Tian, Guang-lei; Chen, Shan-lin; Tian, Wen

    2012-12-18

    To explore a reconstruction method for complete nail bed defect caused by various kinds of reasons and to retrospectively analyze the effect of application of free full-thickness skin graft for the whole nail unit repair. Between Apr. 2010 and Mar. 2012, the method of free full-thickness skin graft was done for reconstruction of the completely nail unit defect in seven cases. There were 2 male and 5 female patients; the mean age of these patients at the time of surgery was 51.9 years (range: 7 to 70 years). The preoperative diagnoses included two cases of malignant melanoma, one of chronic infection, one of squamous cell carcinoma, two of subungual pigmentation and one of junctional nevus. There were 2 thumb lesions, 3 middle and 2 index finger lesions. Nail unit defect was in the range of 1.5 cm×2 cm to 2.5 cm × 3.5 cm and full thickness skin graft was harvested from the same medial side of upper arm (3 cases), forearm cubital fossa (1 case) and contralateral side of groin region (3 cases). All the patients were followed with an average follow-up time being 10 months. All the free skin graft taken was achieved with 100% in all the 7 cases, even in those patients whose partial cortical bone had been curetted. The skin graft was often bluish initially, and superficial blisters were always noticed within 1.5 months postoperatively and the survival skin graft was smooth eventually, and skin graft was adhered to the underlying bone tightly. There was no epidermal inclusion cyst and no residual nail formation. The skin donor sites were without complications. Aesthetic appearance was assessed by the surgeons and found no unacceptable for their patients. And all the patients were satisfied with the cosmetic appearance and active range of motion of their involved fingers, who did not express a desire to undergo any further of nail reconstruction. Free full-thickness skin grafting for reconstruction of the complete nail unit defect is a simple, safe and effective

  3. Customized mandibular reconstruction plates improve mechanical performance in a mandibular reconstruction model

    PubMed Central

    Gutwald, Ralf; Jaeger, Raimund; Lambers, Floor M.

    2017-01-01

    Abstract The purpose of this paper was to analyze the biomechanical performance of customized mandibular reconstruction plates with optimized strength. The best locations for increasing bar widths were determined with a sensitivity analysis. Standard and customized plates were mounted on mandible models and mechanically tested. Maximum stress in the plate could be reduced from 573 to 393 MPa (−31%) by increasing bar widths. The median fatigue limit was significantly greater (p < 0.001) for customized plates (650 ± 27 N) than for standard plates (475 ± 27 N). Increasing bar widths at case-specific locations was an effective strategy for increasing plate fatigue performance. PMID:27887036

  4. Successful treatment of pediatric nail psoriasis with periodic pustular eruption using topical indigo naturalis oil extract.

    PubMed

    Liang, Chung-Yu; Lin, Tung-Yi; Lin, Yin-Ku

    2013-01-01

    Psoriasis of the nail greatly affects quality of life because of the difficulty in achieving long-lasting remission. Pustular psoriasis of the nail apparatus is characterized by the formation of sterile pustules, starting on one or two fingers or less often on the toes, and spontaneous improvement has rarely been observed. This case presents a girl with refractory nail psoriasis accompanied by periodic pustular eruption that responded well to topical treatment with indigo naturalis oil extract drops, achieving a remission of longer than 1 year. © 2012 Wiley Periodicals, Inc.

  5. A model of convergent plate margins based on the recent tectonics of Shikoku, Japan

    NASA Technical Reports Server (NTRS)

    Bischke, R. E.

    1974-01-01

    A viscoelastic finite element plate tectonic model is applied to displacement data for the island of Shikoku, Japan. The flow properties and geometry of the upper portions of the earth are assumed known from geophysical evidence, and the loading characteristics are determined from the model. The nature of the forces acting on the Philippine Sea plate, particularly in the vicinity of the Nankai trough, is determined. Seismic displacement data related to the 1946 Nankaido earthquake are modeled in terms of a thick elastic plate overlying a fluidlike substratum. The sequence of preseismic and seismic displacements can be explained in terms of two independent processes operating on elastic lithospheric plates: a strain accumulation process caused by vertical downward forces acting on or within the lithosphere in the vicinity of the trench, and a strain release process caused by plate failure along a preexisting zone on weakness. This is a restatement of Reid's elastic rebound theory in terms of elastic lithospheric plates.

  6. Fingernails: Do's and Don'ts for Healthy Nails

    MedlinePlus

    ... you see ridges, dents, or areas of unusual color or shape? Many less than desirable nail conditions can be avoided through proper fingernail care. Others might indicate an underlying condition that needs attention. Your fingernails — composed of laminated layers of a ...

  7. Alterations of Hair and Nail Content of Selected Trace Elements in Nonoccupationally Exposed Patients with Chronic Depression from Different Geographical Regions

    PubMed Central

    Liao, Kuan-Yung; Liao, Heng-Hsin; Niziński, Przemysław; Momčilović, Berislav; Jabłońska-Czapla, Magdalena; Prystupa, Andrzej; Sak, Jarosław J.; Kocjan, Ryszard

    2017-01-01

    The aim of this study was to determine if altered levels of selected trace elements manifest themselves during chronic depression. To identify elements strongly associated with chronic depression, relationships between the elemental contents of hair and nails and the interelement correlations were checked. Inductively coupled plasma mass spectrometry and ion chromatography were used to evaluate the contents of Zn, Cu, Co, Pb, Mn, and Fe in hair and nail samples from a total of 415 subjects (295 patients and 120 healthy volunteers). The study included logistic regression models to predict the probability of chronic depression. To investigate possible intercorrelations among the studied elements, the scaled principal component analysis was used. The research has revealed differences in TE levels in the group of depressed men and women in comparison to the healthy subjects. Statistically significant differences in both hair and nails contents of several elements were observed. Our study also provides strong evidence that the intermediary metabolism of certain elements is age- and gender-dependent. Zn, Mn, Pb, and Fe contents in hair/nails seem to be strongly associated with chronic depression. We found no statistically significant residence-related differences in the contents of studied elements in nonoccupationally exposed patients and healthy subjects. PMID:28386550

  8. Alterations of Hair and Nail Content of Selected Trace Elements in Nonoccupationally Exposed Patients with Chronic Depression from Different Geographical Regions.

    PubMed

    Błażewicz, Anna; Liao, Kuan-Yung; Liao, Heng-Hsin; Niziński, Przemysław; Komsta, Łukasz; Momčilović, Berislav; Jabłońska-Czapla, Magdalena; Michalski, Rajmund; Prystupa, Andrzej; Sak, Jarosław J; Kocjan, Ryszard

    2017-01-01

    The aim of this study was to determine if altered levels of selected trace elements manifest themselves during chronic depression. To identify elements strongly associated with chronic depression, relationships between the elemental contents of hair and nails and the interelement correlations were checked. Inductively coupled plasma mass spectrometry and ion chromatography were used to evaluate the contents of Zn, Cu, Co, Pb, Mn, and Fe in hair and nail samples from a total of 415 subjects (295 patients and 120 healthy volunteers). The study included logistic regression models to predict the probability of chronic depression. To investigate possible intercorrelations among the studied elements, the scaled principal component analysis was used. The research has revealed differences in TE levels in the group of depressed men and women in comparison to the healthy subjects. Statistically significant differences in both hair and nails contents of several elements were observed. Our study also provides strong evidence that the intermediary metabolism of certain elements is age- and gender-dependent. Zn, Mn, Pb, and Fe contents in hair/nails seem to be strongly associated with chronic depression. We found no statistically significant residence-related differences in the contents of studied elements in nonoccupationally exposed patients and healthy subjects.

  9. Cryotherapy for docetaxel-induced hand and nail toxicity: randomised control trial.

    PubMed

    McCarthy, Alexandra L; Shaban, Ramon Z; Gillespie, Kerri; Vick, Joanne

    2014-05-01

    This study investigated the efficacy and safety of cryotherapy, in the form of frozen gel gloves, in relation to docetaxel-induced hand and fingernail toxicities. After piloting with 21 patients, a consecutive series sample of patients (n=53) prescribed docetaxel every 3 weeks, for a minimum of three cycles, was enrolled in this randomised control trial. Participants acted as their own control, with the frozen gel glove worn on one randomised hand for 15 min prior to infusion, for the duration of the infusion, and for 15 min of after completion of treatment. Hand and nail toxicities were evaluated by two blinded assessors according to CTCAE.v4 criteria. To assess the potential for cross-infection of multi-use gloves, microbial culture and sensitivity swabs were taken of each glove at every tenth use. Of the 53 participants enrolled in the main study, 21 provided evaluable data. There was a 60 % withdrawal rate due to patient discomfort with the intervention. The mean incidence and severity of toxicities in all evaluable cycles in control and intervention hands respectively were erythroderma grade 1 (5/5 %), nail discolouration grade 1 (81/67 %), nail loss grade 1 (19/19 %) and nail ridging grade 1 (57/57 %). No significant differences were determined between hand conditions in terms of time to event, nor in terms of toxicity in gloved and non-gloved hands. While cryotherapy in the form of frozen gloves for the cutaneous toxicities associated with docetaxel is safe, its limited efficacy, patient discomfort and some logistical issues preclude its use in our clinical setting.

  10. Influence of Femoral Component Design on Retrograde Femoral Nail Starting Point.

    PubMed

    Service, Benjamin C; Kang, William; Turnbull, Nathan; Langford, Joshua; Haidukewych, George; Koval, Kenneth J

    2015-10-01

    Our experience with retrograde femoral nailing after periprosthetic distal femur fractures was that femoral components with deep trochlear grooves posteriorly displace the nail entry point resulting in recurvatum deformity. This study evaluated the influence of distal femoral prosthetic design on the starting point. One hundred lateral knee images were examined. The distal edge of Blumensaat's line was used to create a ratio of its location compared with the maximum anteroposterior condylar width called the starting point ratio (SPR). Femoral trials from 6 manufacturers were analyzed to determine the location of simulated nail position in the sagittal plane compared with the maximum anteroposterior prosthetic width. These measurements were used to create a ratio, the femoral component ratio (FCR). The FCR was compared with the SPR to determine if a femoral component would be at risk for retrograde nail starting point posterior to the Blumensaat's line. The mean SPR was 0.392 ± 0.03, and the mean FCR was 0.416 ± 0.05, which was significantly greater (P = 0.003). The mean FCR was 0.444 ± 0.06 for the cruciate retaining (CR) trials and was 0.393 ± 0.04 for the posterior stabilized trials; this difference was significant (P < 0.001). The FCR for the femoral trials studied was significantly greater than the SPR for native knees and was significantly greater for CR femoral components compared with posterior stabilized components. These findings demonstrate that many total knee prostheses, particularly CR designs, are at risk for a starting point posterior to Blumensaat's line.

  11. Biocompatibility of sol-gel-derived titania-silica coated intramedullary NiTi nails.

    PubMed

    Muhonen, V; Kujala, S; Vuotikka, A; Aäritalo, V; Peltola, T; Areva, S; Närhi, T; Tuukkanen, J

    2009-02-01

    We investigated bone response to sol-gel-derived titania-silica coated functional intramedullary NiTi nails that applied a continuous bending force. Nails 26 mm in length, either straight or with a radius of curvature of 28 or 15 mm, were implanted in the cooled martensite form from a proximal to distal direction into the medullary cavity of the right femur in 40 Sprague-Dawley rats. Body temperature restored the austenite form, causing the curved implants to generate a bending force on the bone. The femurs were examined after 24 weeks. Bone length measurements did not reveal any bowing or shortening of the bone in the experimental groups. The results from histomorphometry demonstrated that the stronger bending force, together with sol-gel surface treatment, resulted in more bone deposition around the implant and the formation of significantly less fibrous tissue. Straight intramedullary nails, even those with a titania-silica coating, were poorly attached when compared to the implants with a curved austenite structure.

  12. [Comparative study of the treatment of pertrochanteric fractures--trochanteric gamma nail vs. proximal femoral nail].

    PubMed

    Megas, P; Kaisidis, A; Zouboulis, P; Papas, M; Panagopoulos, A; Lambiris, E

    2005-01-01

    We have performed a retrospective comparative study between the trochanteric gamma nail (TGN) and the proximal femoral nail (PFN). During the period 1998-2003, 97 TGN and 83 PFN were used for the treatment of pertrochanteric fractures. Most of the fractures were of the A3 type according to the AO/ASIF classification. Clinical and radiological follow-ups were available for 87 TGN and 65 PFN. The mean operative time for the TGN was shorter than that for the PFN. Intraoperative complications were noted in 17.5 % and 28.8 % for the TGN and PFN groups, respectively. Late complications occurred in 18.4 % for TGN compared to 27.6 % of the PFN. Union was achieved in 94.2 % and 89.3 % of the patients treated with the TGN and PFN, respectively. The reoperation rates were 10.3 % and 24.6 % for the TGN and the PFN, respectively. Clinical outcomes were good for both groups (65 % in the TGN, 62 % in the PFN group). Treatment of pertrochanteric fractures using the TGN and PFN implants is quite reliable. The major complication was cut-out and occurred mostly in the PFN group, while varus deformity was more frequent in the TGN group. The PFN was associated with a higher rate of reoperation and longer operative time, probably due to a more demanding technique.

  13. Pathogenic Dermatophytes Survive in Nail Lesions During Oral Terbinafine Treatment for Tinea Unguium.

    PubMed

    Iwanaga, Tomoyuki; Ushigami, Tsuyoshi; Anzawa, Kazushi; Mochizuki, Takashi

    2017-08-01

    Tinea unguium caused by dermatophyte species are usually treated with oral antimycotic, terbinafine (TBF). To understand the mechanisms of improvement and recalcitrance of tinea unguium by oral TBF treatment, a method of quantifying dermatophyte viability in the nail was developed, and the viability of dermatophytes was analyzed in toenail lesions of 14 patients with KOH-positive tinea unguium treated with oral TBF 125 mg/day for up to 16 weeks. Mycological tests, including KOH examination and fungal culture, and targeted quantitative real-time PCR for internal transcribed spacer (ITS) region, including rRNA, were demonstrated at the initial visit and after 8 and 16 weeks of treatment. Assays in eight patients showed that average ITS DNA amount significantly decreased, to 44% at 8 weeks and 36% at 16 weeks compared with 100% at initial visit. No significant difference was observed between at 8 and 16 weeks, despite the TBF concentration in the nail supposedly more than 10-fold higher than the minimum fungicidal concentration for dermatophytes. This finding suggests the pathogenic dermatophytes in nail lesions could survive in a dormant form, such as arthroconidia, during oral TBF treatment. Both antimycotic activity and nail growth are important factors in treatment of tinea unguium.

  14. Modeling of composite beams and plates for static and dynamic analysis

    NASA Technical Reports Server (NTRS)

    Hodges, Dewey H.; Atilgan, Ali R.; Lee, Bok Woo

    1990-01-01

    A rigorous theory and corresponding computational algorithms was developed for a variety of problems regarding the analysis of composite beams and plates. The modeling approach is intended to be applicable to both static and dynamic analysis of generally anisotropic, nonhomogeneous beams and plates. Development of a theory for analysis of the local deformation of plates was the major focus. Some work was performed on global deformation of beams. Because of the strong parallel between beams and plates, the two were treated together as thin bodies, especially in cases where it will clarify the meaning of certain terminology and the motivation behind certain mathematical operations.

  15. [Tibiocalcaneal arthrodesis using retrograde insertion of a compression nail].

    PubMed

    Bölderl, A; Dallapozza, C; Wille, M

    2011-12-01

    OPERATION GOAL: Arthrodesis of the upper and lower ankle joint because of problematic bone positioning or failed arthrodesis. Osteosynthesis procedure using a retrograde compression nail. To achieve stable, fully weight-bearing osteosynthesis for early, pain-free mobilization. Rearthrodesis because of failure of the conventional arthrodesis technique and development of osteoarthritis of the lower ankle joint. Painful osteoarthritis of the upper ankle joint because of inadequate perfusion or a major bone defect because of sclerosis or necrosis. Primary arthrodesis because of facture of the lower leg (pilon tibial) with joint involvement and preexisting osteoarthritis. Acute osteitis/osteomyelitis, sclerosis in the marrow of the distal tibia, malalignment of the distal tibial shaft and local soft tissue inflammation. Preparation of the articular surface of the upper and lower ankle for arthrodesis using a transfibular approach. If necessary, correction of bone defects with iliac crest spongiosa. Stabile osteosynthesis by retrograde insertion of a compression nail. A split lower leg cast on the 2nd postoperative day, mobilization of the patient with underarm crutches with floor contact for 2 weeks, then with application of a lower leg walking cast for 8 weeks with partial weight-bearing for 4 weeks and full weight-bearing for the last 4 weeks of cast fixation. X-ray controls immediately postoperatively, then after 6 and 12 weeks. From 2006 to 2008, 12 patients (7 men, 5 women; mean age 59 years) with various indications were treated with retrograde insertion of a compression nail. All patients were routinely controlled radiologically and clinically after 2, 4, 8 and 12 weeks. Follow-up was carried out at 6, 12 and 24 months. All arthrodeses showed osseous consolidation 16 weeks postoperatively. Ten patients were able to use full weight-bearing without pain after 12 weeks. Two patients reported experiencing pain after walking for 2 h. In total three

  16. Arthrodesis of the knee with a modular titanium intramedullary nail.

    PubMed

    Arroyo, J S; Garvin, K L; Neff, J R

    1997-01-01

    We retrospectively studied the results of arthrodesis of the knee with a modular titanium intramedullary nail that couples at the knee. The study group consisted of thirteen patients who had a malignant tumor around the knee, five who had failure of a total knee arthroplasty, and three who had a locally destructive benign tumor about the knee. All of the patients were followed for a minimum of two years. Through a single incision at the knee, one nail was inserted retrograde into the femur and the other, antegrade into the tibia; the two nails were joined at the level of the knee by a conical couple and were secured with locking screws. The diameters of the nails were different, to accommodate the dissimilar sizes of the tibial and femoral intramedullary canals. A solid osseous fusion was achieved in nineteen (90 per cent) of the twenty-one patients (sixteen who had had resection of a tumor and three who had had a failed arthroplasty), at an average of 8.4 months (range, three to nineteen months) after the operation. One patient had a delayed union, but fusion was achieved after additional bone-grafting. Of the sixteen patients who were available for clinical and radiographic evaluation at the time of the study, fifteen were satisfied with the over-all outcome and thirteen had either less pain or the same amount of pain as they had had preoperatively. There were no mechanical failures of the implant and no recurrences of tumor. Complications occurred in eight (38 per cent) of the twenty-one patients: three patients had a stress fracture, three had a peroneal nerve palsy (one of which was transient), one had a superficial wound infection, and one had reflex sympathetic dystrophy.

  17. Speckle-correlation analysis of the microcapillary blood circulation in nail bed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vilenskii, M A; Agafonov, D N; Zimnyakov, D A

    2011-04-30

    We present the results of the experimental studies of the possibility of monitoring the blood microcirculation in human finger nail bed with application of speckle-correlation analysis, based on estimating the contrast of time-averaged dynamic speckles. The hemodynamics at normal blood circulation and under conditions of partially suppressed blood circulation is analysed. A microscopic analysis is performed to visualise the structural changes in capillaries that are caused by suppressing blood circulation. The problems and prospects of speckle-correlation monitoring of the nail bed microhemodynamics under laboratory and clinical conditions are discussed. (optical technologies in biophysics and medicine)

  18. Comparison of knee function in patients with a healed fracture of the femoral shaft fixed with retrograde and antegrade intramedullary nailing.

    PubMed

    Andrzejewski, Krzysztof; Panasiuk, Michał; Grzegorzewski, Andrzej; Synder, Marek

    2013-10-31

    BACKGROUND. Despite extensive current knowledge about fractures of the femoral shaft, the choice between antegrade and retrograde intramedullary (IM) nailing with respect to the future function of the joint serving to introduce the nail continues to raise controversy. To compare knee function in patients with a healed fracture of the femoral shaft fixed by antegrade vs. retrograde IM nailing. MATERIAL AND METHODS. The study involved a group of 65 individuals with traumatic fractures of the femoral shaft who underwent stabilisation with IM nails in the years 2001-2010. Thirty-two cases were retrograde nails (Group R) and 33 antegrade nails (Group A). Patient age at trauma ranged from 19 to 91 years (mean: 47). Knee function was assessed in both groups with the KOOS, KSS1 and KSS2 scoring systems. RESULTS. Knee function as assessed with KOOS differed significantly between retrograde and antegrade nailing, with a greater incidence of poor and fair results in the former and more excellent outcomes in the latter group (p=0.0133). As regards KSS1 and KSS2, there were no significant differences between the groups (p=0.1947, p=0.4038). The range of motion was 86-125 degrees in Group R and 121-125 degrees in Group A. Knee pain was reported by 37.5% of the patients treated with retrograde nailing and 39.4% of those who had the IM nail inserted via the antegrade approach (p=0.22). The mean time to bone union was 180 days in Group R and 219 days in Group A (p=0.25). Age and presence of osteoarthritis at trauma significantly lowered the KOOS (p=0.0027, p= 0.005) and KSS (p=0.0002, p=0.002) scores, as well as the knee range of motion (p=0.0014, p=0.004) CONCLUSIONS. 1. Knee function following retrograde and antegrade IM nailing to stabilise femoral shaft fractures was comparable. 2. The choice of IM nailing method should not be based solely on orthopaedic indications, but also on the severity of osteoarthritis present at trauma.

  19. [Treatment of periprosthetic femoral fractures after total hip arthroplasty with specially constructed retrograde hollow nails].

    PubMed

    Szalay, G; Meyer, C; Mika, J; Schnettler, R; Thormann, U

    2014-12-01

    Treatment of periprosthetic fractures by implantation of a specially constructed, retrograde hollow nail which fits over the tip of the prosthesis and becomes locked on it. Periprosthetic femoral fractures with firmly anchored prosthesis shaft after total hip arthroplasty of types B1 and C according to the Vancouver classification. Loosened prosthesis (type B2/B3) and trochanteric fractures (type A). Broken or damaged prosthesis, florid inflammation and soft tissue injuries in the operation field, contracted knee joint, advanced deformation in the knee joint and distal femur, enclosed prosthesis and general contraindications. In a supine position the periprosthetic fracture is exposed via a lateral access. For cemented prostheses the cement is removed around the tip of the prosthesis (at least 2-3 cm) and medullary cavity. Arthrotomy with flexion of the knee joint and marking of the nail entry point. Drill the medullary cavity, retrograde introduction of the nail, visually fit the nail over the tip of the prosthesis and lock the nail with the prosthesis. If necessary use additional spongiosaplasty or also placement of additional cerclages depending on fracture type and size of the defect zone. Lock the nail distally. Use intraoperative radiological imaging to control correct positioning and length of the nail. Close the wound layer by layer with placement of suction drainage devices and dressing. Partial loading for 6 weeks with a subsequent pain-adapted loading gradient until full loading is possible. If selective partial loading is not possible, a decision must be made in individual cases as to whether the intraoperative findings allow immediate full loading. From 2004 to 2011 a total of 25 periprosthetic femoral fractures in 25 patients were treated in 2 locations using specially constructed slotted hollow nails. Within the framework of a retrospective study 20 of these patients (16 female and 4 male; average age 77.2 [72-84] years) were clinically and

  20. 76 FR 52313 - Certain Steel Nails From the United Arab Emirates: Postponement of Preliminary Determination of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-22

    ... United Arab Emirates: Postponement of Preliminary Determination of Antidumping Duty Investigation AGENCY... antidumping duty investigation on nails from the United Arab Emirates. See Certain Steel Nails From the United Arab Emirates: Initiation of Antidumping Duty Investigation, 76 FR 23559 (April 27, 2011). The notice...

  1. A comparative study of the therapeutic effect between long and short intramedullary nails in the treatment of intertrochanteric femur fractures in the elderly.

    PubMed

    Guo, Xue-Feng; Zhang, Ke-Ming; Fu, Hong-Bo; Cao, Wen; Dong, Qiang

    2015-01-01

    To compare the clinical effects of long vs. short intramedullary nails in the treatment of intertrochanteric fractures in old patients more than 65 years old. A retrospective analysis of 178 cases of intertrochanteric fractures of the femur (AO type A1 and A2) in the elderly was conducted from January 2008 to December 2013. There were 85 males (47.8%) and 93 females (52.2%) with the age of 65e89 (70.2±10.8) years. The patients were treated by closed reduction and long or short intramedullary nail (Gamma 3) fixation. The length of short nail was 180 mm and that for long nail was 320e360 mm. The general data of patients, operation time, intraoperative blood loss, length of hospital stay, preoperative hemoglobin level, blood transfusion rate, postoperative periprosthetic fractures, infections, complications, etc were carefully recorded. There were 76 cases (42.7%) in the long intramedullary nail group and 102 cases (57.3%) in the short nail group. All the cases were followed up for 12e48 (21.3±6.8) months, during which there were 21 deaths (11.8%), mean (13.8±6.9) months after operation. The intraoperative blood loss was (90.7±50.6) ml in short nail group, greatly less than that in long nail group (127.8±85.9) ml (p=0.004). The short nail group also had a significantly shorter operation time (43.5 min±12.3 min vs. 58.5 min±20.3 min, p=0.002) and lower rate of postoperative transfusion (42.3% vs. 56.7%, p=0.041). But the length of hospital stay showed no big differences. After operation, in each group there was 1 case of periprosthetic fracture with a total incidence of 1.1%, 1.3% in long nail group and 0.9% in short nail group. At the end of the follow-up, all patients achieved bony union. The average healing time of the long nail group was (6.5±3.1) months, and the short nail group was (6.8±3.7) months, revealing no significant differences (p=0.09). Postoperative complications showed no great differences either. Both the intramedullary long and short nail

  2. Knee arthrodesis for limb salvage with an intramedullary coupled nail.

    PubMed

    Senior, Colin J; da Assunção, Ruy E; Barlow, Ian W

    2008-07-01

    The demand for revision and salvage procedures after knee arthroplasty is increasing as the number of primary procedures increases. Surgical salvage techniques when revision arthroplasty is contra-indicated include above knee amputation and arthrodesis. The results of arthrodesis are functionally superior to those of amputation but not all techniques of arthrodesis are associated with good results. We present a single surgeon series of 14 consecutive patients who underwent arthrodesis of the knee with a customised intramedullary coupled nail (Mayday arthrodesis nail, Orthodesign Ltd, UK). All patients had a failed knee arthroplasty due to persistent sepsis. Pre-operative scaled radiographs were used to design and manufacture a custom-made implant for each patient. An identical surgical technique and post-operative rehabilitation regime were used in each case. The mean hospital stay was 12 days (range 6-24). Union was achieved in all but one patient at a mean of 4 months (range 3-10). One diabetic patient required subsequent above knee amputation for infected non-union. Two other patients had significant transient complications. We have found that the Mayday nail offers a straightforward, reproducible surgical option for difficult salvage surgery. Good results have been obtained in the majority of cases, avoiding the devastating consequences of above knee amputation.

  3. Titanium elastic nail - Complications in the treatment of paediatric diaphyseal fracture of femur [corrected].

    PubMed

    Sarkar, Saikat; Bandyopadhyay, Ranadeb; Mukherjee, Arindam

    2013-01-01

    Femoral shaft fracture is the most common major paediatric orthopaedic. For generations traction and casting was the standard treatment for all femoral shaft fractures in children. Over the past two decades the advantages of fixation and rapid mobilisation have been increasingly recognised. A prospective study was conducted in five private hospitals in the district of Bankura, West Bengal over a period of two years (April 2010 to March 2012) on 70 patients with closed shaft femur fractures between 6- 14 years age of either sex. The aim was to find out the short term complications of titanium elastic nailing in diaphyseal fracture of femur in children and compare the findings of this study with pre- existing studies in this field. In our study the most common complication was pain at nail entry site (60%). 5.71% had local inflammatory reaction due to nails. Superficial infection occurred in 2.85%. At the end of 1 year, 2.85% had limb length discripancies. Proximal migration occurred in 2.85%. 2.85% encountered acute reactive synovitis, 5.71% developed angulation of fracture site and 2.85% developed per operative breakage of nail. The treatment of paediatric shaft femur fracture has been drastically changed over the last two decades to internal fixation by elastically stable intra- medullary nail (ESIN). In our study, we encountered only a few complications most of them being minor. Most of the complications were surgical technique related and were seen at the initial phase of the learning curve.

  4. Global Models of Ridge-Push Force, Geoid, and Lithospheric Strength of Oceanic plates

    NASA Astrophysics Data System (ADS)

    Mahatsente, Rezene

    2017-12-01

    An understanding of the transmission of ridge-push related stresses in the interior of oceanic plates is important because ridge-push force is one of the principal forces driving plate motion. Here, I assess the transmission of ridge-push related stresses in oceanic plates by comparing the magnitude of the ridge-push force to the integrated strength of oceanic plates. The strength is determined based on plate cooling and rheological models. The strength analysis includes low-temperature plasticity (LTP) in the upper mantle and assumes a range of possible tectonic conditions and rheology in the plates. The ridge-push force has been derived from the thermal state of oceanic lithosphere, seafloor depth and crustal age data. The results of modeling show that the transmission of ridge-push related stresses in oceanic plates mainly depends on rheology and predominant tectonic conditions. If a lithosphere has dry rheology, the estimated strength is higher than the ridge-push force at all ages for compressional tectonics and at old ages (>75 Ma) for extension. Therefore, under such conditions, oceanic plates may not respond to ridge-push force by intraplate deformation. Instead, the plates may transmit the ridge-push related stress in their interior. For a wet rheology, however, the strength of young lithosphere (<75 Ma) is much less than the ridge-push force for both compressional and extensional tectonics. In this case, the ridge-push related stress may dissipate in the interior of oceanic plates and diffuses by intraplate deformation. The state of stress within a plate depends on the balance of far-field and intraplate forces.

  5. Mechanical Performance of Nail-Laminated Posts Manufactured from Reclaimed Chromated Copper Arsenate-Treated Decking Lumber

    Treesearch

    John J. Janowiak; Robert H. Falk; Brad A. Gething; John A. Tsirigotis

    2014-01-01

    This study determined the mechanical properties of nail-laminated (nail-lam) posts manufactured from reclaimed chromated copper arsenate (CCA)–treated decking lumber. Though CCA-treated lumber is no longer accepted for use in residential applications, it is permitted in agricultural and industrial applications where health and environmental impacts are deemed to be...

  6. Segmental transport after unreamed intramedullary nailing. Preliminary report of a "Monorail" system.

    PubMed

    Raschke, M J; Mann, J W; Oedekoven, G; Claudi, B F

    1992-09-01

    The Ilizarov method of segmental bone transport has been shown to be an alternative to more conventional treatments of posttraumatic bony defects. After extensive clinical experience with the unreamed tibial nail in open fractures up to Grade IIIb, a new monorail fixation system for callus distraction and segmental bone transport was devised. This Monorail system is composed of an unreamed intramedullary (IM) nail and a unilateral AO distraction device. The new fixation method and the preliminary clinical experience are reported here. Four patients who previously sustained Grades II-IIIb open tibial fractures had an average bony defect of 9 cm. Two patients had previous bony infections. All patients had had serial debridements and myocutaneous flaps were required in three patients. An unreamed IM nail was inserted, and the transport device was applied. After an osteotomy, segmental transport was carried out until docking was achieved. The external fixator was removed after interlocking of the transported segment. The mean duration of external fixation was 17.9 days/cm and the mean period until roentgenographic consolidation of the distraction and nonunion site was 41.2 days/cm. There were two pin-tract infections but no IM infections. One nail broke after osseous consolidation of the regenerate at the distal interlocking site and required exchange. The goal of transport was achieved in all cases without angular or rotational deformity or length discrepancy. There were no neurovascular injuries.

  7. Dynamic osteosynthesis by modified Kuntscher nail for the treatment of tibial diaphyseal fractures.

    PubMed

    Gadegone, Wasudeo M; Salphale, Yogesh S

    2009-04-01

    We evaluated a series of diaphyseal fractures of the tibia using low-cost, Indian-made modified Kuntscher nail (Daga nail) with the provision of distal locking screw for the management of the tibial diaphyseal fractures. One hundred and fifty one consecutive patients with diaphyseal fractures of tibia with 151 fractures who were treated by Daga nail were enrolled. One of the patients who had died because of cancer, and the two patients who were lost to follow-up at 3 months were excluded from the study.Therefore data of 148 patients with one hundred and fortyeight fractures is described. One hundred twenty closed fractures, 20 open Grade I fractures, and eight open Grade II fractures as per Gustilo and Anderson classification were included in this study. One hundred fourteen men and 34 women, with a mean age of 38.4 years, were studied. The result were analysed for Surgical time, duration of hospitalisation, union time, union rate, complication rate, functional recovery and crutch walking time. The fractures were followed at least until the time of solid union. The follow-up period averaged 15 months (range, 6-26 months). Union occurred in 140 cases (94.6%). The mean time to union was 13 weeks for closed fractures,17.8 weeks for Grade I open fractures, and 21.6 weeks for Grade II open fractures. Compartment syndrome occurred in two patients. Superficial infection occurred in five cases of Grade I and II compound fractures. Three closed fractures and one case of Grade I compound fracture required bone grafting for delayed union. Two cases of Grade II compound fracture with nonunion required revision surgery and bone grafting. Twelve cases resulted in acceptable malalignment due to operative technical error. In four cases, the distal screw breakage was seen, but none of these complications interfered with fracture healing. Recovery of joint motion was essentially normal in those patients without knee or ankle injury. Unreamed distally locked dynamic tibial nailing

  8. Effect of autocontrol micromotion intramedullary interlocking nail on fracture healing: an experimental study.

    PubMed

    Xu, Wei-zhou; Guo, Xiao-dong; Zhao, Ju-cai; Wang, Yi-jin

    2006-06-01

    To investigate the effect of autocontrol micromotion locking nail (AMLN) on experimental fracture healing and its mechanism. 16 goats undergoing both sides of transverse osteotomy of the femoral shafts were fixed intramedullary with AMLN and Gross-Kempf (GK) nail, respectively. The follow-up time was 7, 14, 28 and 56 days. Roentgenographic, biomechanical, histological, scanning electromicroscopic and biochemical analyses were done. (1) The strength of anticompression, antiflexion and antitorsion in the fractural end in the AMLN-fixed group was higher than that of GK nail-fixed group; whereas, the rate of stress shelter in the fractured end decreased significantly (P<0.01). (2) The content of the total collagen, insoluble collagen, calcium and phosphate in the AMLN-fixed group was higher than that in the GK nail-fixed group (P<0.05). (3) Histological observation and quantitative analysis of calluses revealed that AMLN could promote the growth of bridge calluses and periosteum calluses. Hence the fracture healing and remolding process achieved early, which was much better than traditional GK nail fixation. (P<0.05). (4) 7-14 days postoperation, the calluses of AMLN-fixed group was flourish and camellarly arranged and the collagen fibril formed constantly in the absorption lacuna of bone trabecula. 28-56 days postoperation, the collagen fibril was flourish around the absorption lacuna and was parallel to the bone's longitudinal axis. Active bony absorption and formation were seen, so was remolding and rebuilding. Haversian system was intact and the bony structural net was very tenacious because of the deposition of calcium salt. None of the above findings was observed in the GK nail-fixed group. The design of AMLN accords well with the plastic fixation theory. As the geometry ametabolic system constituted by the intramedullary fixation instruments and the proximal and distal end of the fracture is very firm and stable, the disturbance to the physical stress

  9. Modeling and simulation of clutch pressure plate casting using alternate materials

    NASA Astrophysics Data System (ADS)

    Madhuraj, H. N.; Bharath, M. R.

    2018-04-01

    Clutch Pressure Plate is a stress bearing component in the clutch assembly. Cast iron alloys like FG300, G2500 are commonly used for clutch pressure plate castings. These materials have high compressive strength, low tensile strength & no ductility but these cost high for the manufacturers. There is a need for alternate material so as to reduce cost, defects in castings without losing the life and effectiveness of the clutch plate. The work carried out here is modeling the clutch pressure plate using CAD tool. And then the casting process is simulated by casting simulation for fluid flow and solidification analysis by trying alternate material. Here the castability of the alternate material En-Gjs-400-15 and the commonly used material FG300 for the clutch pressure plate component is analyzed by designing and optimizing a proper gating system.

  10. Knee arthrodesis using a customised modular intramedullary nail in failed infected total knee arthroplasty.

    PubMed

    Putman, S; Kern, G; Senneville, E; Beltrand, E; Migaud, H

    2013-06-01

    Knee arthrodesis is used to treat patients with failed infected total knee arthroplasty (TKA). Among fixation methods, intramedullary nailing increases the chances of bone union but may carry a risk of infection around the nail. This risk is not well understood, because available case-series studies were not confined to patients with knee infection. Infection recurrence rates after knee arthrodesis with intramedullary nailing used to treat failed infected TKA are similar to those seen with other fixation methods. We retrospectively reviewed 31 cases of knee arthrodesis with fixation by a modular intramedullary nail performed at a subspecialized center treating complex osteoarticular infections (CRIOAC). The antibiotic regimen was determined based on multidisciplinary discussions and microbiological studies of preoperative and intraoperative specimens. Mean follow-up was 50 ± 22 months (range, 28-90 months). Arthrodesis was performed in one stage (n=6) or two stages (n=25). Success was defined as presence, after a postoperative follow-up of at least 24 months, based on the following criteria: normal erythrocyte sedimentation rate and/or C-reactive protein, no wound inflammation or sinus tract, no revision surgery, and no antibiotic treatment. Bone union was not a criterion for a successful arthrodesis procedure. Removal of the fixation material was required in three patients and long-term palliative antibiotic therapy in three patients (fixation material in place with repeated positive specimens) for a total of six failures due to infection (6/31, 19.4%). None of the patients experienced mechanical failure (no breakage of the material and no fixation failure of the nails designed to allow osteointegration). The mean leg length discrepancy was 10 ± 10 mm (range, 5-34 mm) and the mean Oxford score was 41 ± 11 (range, 23-58). The 50-month rate of arthrodesis survival to revision surgery for nail removal was 77.8 ± 4% and the 50-month rate of arthrodesis survival

  11. A comparative biomechanical analysis of implants for the stabilization of proximal humerus fractures.

    PubMed

    Füchtmeier, B; May, R; Fierlbeck, J; Hammer, J; Nerlich, M

    2006-01-01

    A new humerus nail (Sirus) has become available for the treatment of fractures of the proximal humerus. The aim of the study was the biomechanical comparison of this implant with established systems. 12 matched pairs of human humeri were employed for testing. Three randomized groups were formed (n = 4 pairs). A bending moment of 7.5 Nm and a torsional moment of 8.3 Nm were applied in a test of five loading cycles to all intact bones. Loading was consistently initiated at the distal epiphysis. The consequent deformation at the distal epiphysis was continuously recorded. Then an osteotomy with a defect of 5 mm was created to simulate an unstable subcapital humerus fracture. For paired comparison, one of each pair was stabilized with the Sirus proximal humerus nail. The other side was fixed with a reference implant. The following groups were created.: Group I: Sirus versus Proximal humerus nail (PHN) with spiral blade. Group II: Sirus versus PHILOS plate. Group III: Sirus versus 4.5 mm AO T-plate. The proximal humerus nail (Sirus) demonstrated significantly higher stiffness values than the reference implants for both bending and torsional load. The following values were recorded at a bending moment of 7.5 Nm: Sirus 14.2 mm, PHN 20.7 mm, PHILOS plate 28.1 mm, 4.5 AO T-plate 29.3 mm p < 0.0012). The values at 8.3 Nm torsional moment were: Sirus 8.5 degrees , PHN 12.3 degrees , PHILOS plate 16.4 degrees , 4.5 AO T-Platte 15.6 degrees (p < 0.002). The intramedullary load carriers were biomechanically superior when compared to the plating systems in the fracture model presented here. Supplementary, the Sirus Nail showed higher stiffness values than the PHN. However, the latter are gaining in importance due to the possibility of minimal invasive implantation. Whether this will be associated with functional advantages requires further clinical investigation.

  12. Nail Biting; Etiology, Consequences and Management

    PubMed Central

    Ghanizadeh, Ahmad

    2011-01-01

    Nail biting (NB) is a common, but unresolved, problem in psychiatry, psychology, medicine and dentistry. While it seems that NB is a simple behavior that can be stopped easily, many of the children with NB have already tried to stop it, but they have not been successful. The frustrations due to failed attempt involve others such as parents and siblings. The present review aims at providing an overview of prevalence, co-morbidities, education and counseling, and management for NB. Overall, the reviewed literatures suggest that co-morbidities of psychiatric disorders and other stereotypic behaviors in clinical sample of children with NB is more than 80%, and more than half of the parents suffer from psychiatric disorders mainly depression. Treatment of NB, however, is not as easy as it seems. The management of NB is much more complicated than just focusing on stopping it. Nail biting cannot be managed without considering its co-morbidities, antecedents and consequences. It might be concluded form the reviewed literature that children with NB, parents, siblings, and teachers should be educated about what to do and what not to do about NB. Punishment is not effective. Moreover, clinical randomized controlled trials are required to make available evidence-based behavioral and pharmacologic treatment protocols. PMID:23358880

  13. Miltefosine is effective against Candida albicans and Fusarium oxysporum nail biofilms in vitro.

    PubMed

    Machado Vila, Taissa Vieira; Sousa Quintanilha, Natália; Rozental, Sonia

    2015-11-01

    Onychomycosis is a fungal nail infection that represents ∼50 % of all nail disease cases worldwide. Clinical treatment with standard antifungals frequently requires long-term systemic therapy to avoid chronic disease. Onychomycosis caused by non-dermatophyte moulds, such as Fusarium spp., and yeasts, such as Candida spp., is particularly difficult to treat, possibly due to the formation of drug-resistant fungal biofilms on affected areas. Here, we show that the alkylphospholipid miltefosine, used clinically against leishmaniasis and cutaneous breast metastases, has potent activity against biofilms of Fusarium oxysporum and Candida albicans formed on human nail fragments in vitro. Miltefosine activity was compared with that of commercially available antifungals in the treatment of biofilms at two distinct developmental phases: formation and maturation (pre-formed biofilms). Drug activity towards biofilms formed on nail fragments and on microplate surfaces (microdilution assays) was evaluated using XTT [2,3-bis(2-methoxy-4-nitro-5-sulfophenyl)-2H-tetrazolium-5-carboxanilide] assays, and drug effects on fingernail biofilms were analysed by scanning electron microscopy (SEM). For F. oxysporum, miltefosine at 8 μg ml- 1 inhibited biofilm formation by 93%, whilst 256 μg ml- 1 reduced the metabolic activity of pre-formed nail biofilms by 93%. Treatment with miltefosine at 1000 μg ml- 1 inhibited biofilm formation by 89% and reduced the metabolic activity of pre-formed C. albicans biofilms by 99%. SEM analyses of biofilms formed on fingernail fragments showed a clear reduction in biofilm biomass after miltefosine treatment, in agreement with XTT results. Our results show that miltefosine has potential as a therapeutic agent against onychomycosis and should be considered for in vivo efficacy studies, especially in topical formulations for refractory disease treatment.

  14. Elastic nailing of tibia shaft fractures in young children up to 10 years of age.

    PubMed

    Heo, Jeong; Oh, Chang-Wug; Park, Kyeong-Hyeon; Kim, Joon-Woo; Kim, Hee-June; Lee, Jong-Chul; Park, Il-Hyung

    2016-04-01

    Although tibia shaft fractures in children usually have satisfactory results after closed reduction and casting, there are several surgical indications, including associated fractures and soft tissue injuries such as open fractures. Titanium elastic nails (TENs) are often used for pediatric tibia fractures, and have the advantage of preserving the open physis. However, complications such as delayed union or nonunion are not uncommon in older children or open fractures. In the present study, we evaluated children up to 10 years of age with closed or open tibial shaft fractures treated with elastic nailing technique. A total of 16 tibia shaft fractures treated by elastic nailing from 2001 to 2013 were reviewed. The mean patient age at operation was 7 years (range: 5-10 years). Thirteen of 16 cases were open fractures (grade I: 4, grade II: 6, grade IIIA: 3 cases); the other cases had associated fractures that necessitated operative treatments. Closed, antegrade intramedullary nailing was used to insert two nails through the proximal tibial metaphysis. All patients were followed up for at least one year after the injury. Outcomes were evaluated using modified Flynn's criteria, including union, alignment, leg length discrepancies, and complications. All fractures achieved union a mean of 16.1 weeks after surgery (range: 11-26 weeks). No patient reported knee pain or experienced any loss of knee or ankle motion. There was a case of superficial infection in a patient with grade III open fracture. Three patients reported soft tissue discomfort due to prominent TEN tips at the proximal insertion site, which required cutting the tip before union or removing the nail after union. At the last follow-up, there were no angular or rotational deformities over 10° in either the sagittal or coronal planes. With the exception of one case with an overgrowth of 15 mm, no patient showed shortening or overgrowth exceeding 10mm. Among final outcomes, 15 were excellent and 1 was

  15. Nailing Pompeii

    NASA Astrophysics Data System (ADS)

    Showstack, Randy

    Roman hihstorian Pliny the Younger noted that Mount Vesuvius blew its top and destroyed Pompeii in the early afternoon of August 24, 1,918 years ago. Now, a team of scientists, tempted by the certainty of that record, has confirmed the eruption to within 7 years. The team developed and used an improved radioactive argon-argon dating technique, which they say can reliably establish the age of rocks as old as the solar system or as recent as 1,000 years old.“We nailed the date to 5% on our first attempt, so we could probably get the error down to 1% or less,” says Paul Renne, adjunct associate professor of geology and geophysics at the University of California at Berkeley and director of the private Berkeley Geochronology Center. “Dating things that are really young has always been the Holy Grail of potassium-argon [an earlier method] and argonargon dating.”

  16. Long-term functional outcome following intramedullary nailing of femoral shaft fractures.

    PubMed

    el Moumni, Mostafa; Voogd, Emma Heather; ten Duis, Henk Jan; Wendt, Klaus Wilhelm

    2012-07-01

    The management of femoral shaft fractures using intramedullary nailing is a popular method. The purpose of this study was to evaluate the long-term functional outcome after antegrade or retrograde intramedullary nailing of traumatic femoral shaft fractures. We further determined predictors of these functional outcome scores. In a retrospective study, patients with a femoral shaft fracture but no other injuries to the lower limbs or pelvis were included. A total of 59 patients met the inclusion criteria. Functional outcome scores (Short Musculoskeletal Functional Assessment (SMFA), Western Ontario and McMaster University Osteoarthritis (WOMAC) index, Harris Hip Score (HHS) and the Lysholm knee function scoring scale) were measured at a mean of 7.8 years (± 3.5 years) postoperatively. The Visual Analogue Scale (VAS) was used to determine pain complaints of the lower limb. The range of motion (ROM) of the hip and knee joints was comparable between the injured and uninjured leg, regardless of the nailing technique. Correlation between ROM and the final outcome scores was found to be fair to moderate. Even years after surgery, 17% of the patients still reported moderate to severe pain. A substantial correlation was observed between VAS and the patient-reported outcome scores. The most significant predictor of functional outcome was pain in the lower limb. Our findings suggest that the ROM of hip and knee returns to normal over time, regardless of the nailing method used. However, pain in the lower limb is an important predictor and source of disability after femoral shaft fractures, even though most patients achieved good functional outcome scores. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Time-domain simulation of damped impacted plates. II. Numerical model and results.

    PubMed

    Lambourg, C; Chaigne, A; Matignon, D

    2001-04-01

    A time-domain model for the flexural vibrations of damped plates was presented in a companion paper [Part I, J. Acoust. Soc. Am. 109, 1422-1432 (2001)]. In this paper (Part II), the damped-plate model is extended to impact excitation, using Hertz's law of contact, and is solved numerically in order to synthesize sounds. The numerical method is based on the use of a finite-difference scheme of second order in time and fourth order in space. As a consequence of the damping terms, the stability and dispersion properties of this scheme are modified, compared to the undamped case. The numerical model is used for the time-domain simulation of vibrations and sounds produced by impact on isotropic and orthotropic plates made of various materials (aluminum, glass, carbon fiber and wood). The efficiency of the method is validated by comparisons with analytical and experimental data. The sounds produced show a high degree of similarity with real sounds and allow a clear recognition of each constitutive material of the plate without ambiguity.

  18. Tibiotalocalcaneal arthrodesis using an intramedullary nail: a systematic review.

    PubMed

    Franceschi, Francesco; Franceschetti, Edoardo; Torre, Guglielmo; Papalia, Rocco; Samuelsson, Kristian; Karlsson, Jón; Denaro, Vincenzo

    2016-04-01

    Tibiotalocalcaneal arthrodesis is aimed to block the ankle joint motion in cases of severe osteoarthritis, avascular necrosis of the talus and/or failure of arthroplasty operations. This systematic review was carried out to evaluate the clinical outcome after tibiotalocalcaneal arthrodesis using intramedullary nail either open and arthroscopically assisted. Focus was on the success rate of the procedure in terms of union and complications and on the comparison between the techniques. The databases PubMed (Medline), EMBASE and Cochrane Library were searched in order to retrieve relevant studies. All therapeutic level 1-4 studies involving humans with intramedullary nail fixation technique were included. Only studies written in English, Italian, French, Spanish and German were included. Data related to the type of surgery, complications and clinical outcomes were extracted and analysed. A total of 83 studies were identified, of which 32 studies were eligible for inclusion; 31 case series and one randomized controlled trial. The main reported outcome score was the American Orthopaedic Foot and Ankle Society scale. Almost, all the included studies reported higher than 50% union rates and a significant improvement in terms of the clinical and mechanical ankle function after treatment. Results suggest that satisfactory outcomes can be achieved by tibiotalocalcaneal arthrodesis using intramedullary nailing. Low complication rates contribute to make this a safe procedure. No comparison can be done between arthroscopic and open technique, due to the lack of scientific works on the first one. IV.

  19. The Modeling of Viscoelastic Circular Plates for Use as Waveguide Absorbers

    DTIC Science & Technology

    1988-09-01

    oncituoe Security Ciasstircation) X THE MODELING OF VISCOELASTIC CIRCULAR PLATES FOR USE AS WAVEGUIDE ABSORBERS C 12 PERSONAL AUTmO ?S) -Hettema...33mvU3dT’U Figure 67. Experimental Jmainiey Part ot the Driving Point Jmpedancs of a 6 in Radius Elastic Plate, With and Without aaker and Mount Conecon, In

  20. Comparison of effectiveness of electrocautery and phenol application in partial matricectomy after partial nail extraction in the treatment of ingrown nails.

    PubMed

    Misiak, Piotr; Terlecki, Artur; Rzepkowska-Misiak, Beata; Wcisło, Szymon; Brocki, Marian

    2014-02-01

    Ingrowing nail also known as onychocryptosis is a common health problem. This disease mostly affects young people, often carrying a considerable amount of socio-economic implications. It's foot problem that usually manifests as inflammation of tissue along the side of a toenail. The aim of the study was to asses and to compare effectiveness of electrocautery and phenol application in partial matrixectomy after partial nail extraction in the treatment of ingrown toenails. The group of 60 patients with ingrowing toenail which was randomized into two groups underwent partial matrixectomy in surgical outpatient clinic between 2009-2013. This group of patients was under surgical observation for 100 days in outpatient clinic. In all operated patients we obtained surgical success however we had 13 recurrences during the follow up period, 5 in the phenolization group and 8 in the electrocoagulation group. There was statistically significant difference between these two techniques, which indicated that matrix phenolization is connected with shortened healing time vs the matrix electrocoagulation.