Sample records for naked-eye optical flash

  1. Naked-eye optical flash from gamma-ray burst 080319B: Tracing the decaying neutrons in the outflow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fan Yizhong; Zhang Bing; Wei Daming

    For an unsteady baryonic gamma-ray burst (GRB) outflow, the fast and slow proton shells collide with each other and produce energetic soft gamma-ray emission. If the outflow has a significant neutron component, the ultrarelativistic neutrons initially expand freely until decaying at a larger radius. The late-time proton shells ejected from the GRB central engine, after powering the regular internal shocks, will sweep these {beta}-decay products and give rise to very bright UV/optical emission. The naked-eye optical flash from GRB 080319B, an energetic explosion in the distant Universe, can be well explained in this way.

  2. FAST OPTICAL VARIABILITY OF A NAKED-EYE BURST-MANIFESTATION OF THE PERIODIC ACTIVITY OF AN INTERNAL ENGINE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beskin, G.; Karpov, S.; Bondar, S.

    We imaged the position of the naked-eye burst, GRB080319B, before, during, and after its gamma-ray activity with sub-second temporal resolution using the TORTORA wide-field camera. The burst optical prompt emission, which reached 5.3 mag, has been detected, and its periodic optical variability has been discovered in the form of four equidistant flashes with a duration of several seconds. We also detected a strong correlation (r {approx} 0.82) between optical and gamma-ray light curves with a 2 s delay of the optical emission with respect to the gamma-ray emission. The revealed temporal structure of the optical light curve in comparison withmore » the gamma-ray light curve can be interpreted in the framework of the model of shell collisions in the ejecta containing a significant neutron component. All observed emission features reflect the non-stationary behavior of the burst internal engine-supposedly, a hyperaccreting solar-mass black hole formed in the collapse of a massive stellar core.« less

  3. Origin of the bright prompt optical emission in the naked eye burst

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hascoeet, R.; Daigne, F.; Mochkovitch, R.

    The huge optical brightness of GRB 080319B (the 'Naked Eye Burst') makes this event really challenging for models of the prompt GRB emission. In the framework of the internal shock model, we investigate a scenario where the dominant radiative process is synchrotron emission and the high optical flux is due to the dynamical properties of the relativistic outflow : if the initial Lorentz factor distribution in the jet is highly variable, many internal shocks will form within the outflow at various radii. The most violent shocks will produce the main gamma-ray component while the less violent ones will contribute atmore » lower energy, including the optical range.« less

  4. Naked-eye 3D imaging employing a modified MIMO micro-ring conjugate mirrors

    NASA Astrophysics Data System (ADS)

    Youplao, P.; Pornsuwancharoen, N.; Amiri, I. S.; Thieu, V. N.; Yupapin, P.

    2018-03-01

    In this work, the use of a micro-conjugate mirror that can produce the 3D image incident probe and display is proposed. By using the proposed system together with the concept of naked-eye 3D imaging, a pixel and a large volume pixel of a 3D image can be created and displayed as naked-eye perception, which is valuable for the large volume naked-eye 3D imaging applications. In operation, a naked-eye 3D image that has a large pixel volume will be constructed by using the MIMO micro-ring conjugate mirror system. Thereafter, these 3D images, formed by the first micro-ring conjugate mirror system, can be transmitted through an optical link to a short distance away and reconstructed via the recovery conjugate mirror at the other end of the transmission. The image transmission is performed by the Fourier integral in MATLAB and compares to the Opti-wave program results. The Fourier convolution is also included for the large volume image transmission. The simulation is used for the manipulation, where the array of a micro-conjugate mirror system is designed and simulated for the MIMO system. The naked-eye 3D imaging is confirmed by the concept of the conjugate mirror in both the input and output images, in terms of the four-wave mixing (FWM), which is discussed and interpreted.

  5. A new rhodamine-based colorimetric chemosensor for naked-eye detection of Cu2 + in aqueous solution

    NASA Astrophysics Data System (ADS)

    Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-li

    2016-03-01

    A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu2 +. The optical feature of 1 for Cu2 + was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu2 +, the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu2 + complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu2 + with high sensitivity.

  6. A new rhodamine-based colorimetric chemosensor for naked-eye detection of Cu(2+) in aqueous solution.

    PubMed

    Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-Li

    2016-03-15

    A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu(2+). The optical feature of 1 for Cu(2+) was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu(2+), the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu(2+) complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu(2+) with high sensitivity. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Micrometer-level naked-eye detection of caesium particulates in the solid state

    NASA Astrophysics Data System (ADS)

    Mori, Taizo; Akamatsu, Masaaki; Okamoto, Ken; Sumita, Masato; Tateyama, Yoshitaka; Sakai, Hideki; Hill, Jonathan P.; Abe, Masahiko; Ariga, Katsuhiko

    2013-02-01

    Large amounts of radioactive material were released from the Fukushima Daiichi nuclear plant in Japan, contaminating the local environment. During the early stages of such nuclear accidents, iodine I-131 (half-life 8.02 d) is usually detectable in the surrounding atmosphere and bodies of water. On the other hand, in the long-term, soil and water contamination by Cs-137, which has a half-life of 30.17 years, is a serious problem. In Japan, the government is planning and carrying out radioactive decontamination operations not only with public agencies but also non-governmental organizations, making radiation measurements within Japan. If caesium (also radiocaesium) could be detected by the naked eye then its environmental remediation would be facilitated. Supramolecular material approaches, such as host-guest chemistry, are useful in the design of high-resolution molecular sensors and can be used to convert molecular-recognition processes into optical signals. In this work, we have developed molecular materials (here, phenols) as an optical probe for caesium cation-containing particles with implementation based on simple spray-on reagents and a commonly available fluorescent lamp for naked-eye detection in the solid state. This chemical optical probe provides a higher spatial resolution than existing radioscopes and gamma-ray cameras.

  8. Immuno Nanosensor for the Ultrasensitive Naked Eye Detection of Tuberculosis.

    PubMed

    Mohd Bakhori, Noremylia; Yusof, Nor Azah; Abdullah, Jaafar; Wasoh, Helmi; Md Noor, Siti Suraiya; Ahmad Raston, Nurul Hanun; Mohammad, Faruq

    2018-06-14

    In the present study, a beneficial approach for the ultrasensitive and affordable naked eye detection and diagnosis of tuberculosis (TB) by utilizing plasmonic enzyme-linked immunosorbent assay (ELISA) via antibody-antigen interaction was studied. Here, the biocatalytic cycle of the intracellular enzymes links to the formation and successive growth of the gold nanoparticles (GNPs) for ultrasensitive detection. The formation of different colored solutions by the plasmonic nanoparticles in the presence of enzyme labels links directly to the existence or non-existence of the TB analytes in the sample solutions. For disease detection, the adapted protocol is based mainly on the conventional ELISA procedure that involves catalase-labeled antibodies, i.e., the enzymes consume hydrogen peroxide and further produce GNPs with the addition of gold (III) chloride. The amount of hydrogen peroxide remaining in the solution determines whether the GNPs solution is to be formed in the color blue or the color red, as it serves as a confirmation for the naked eye detection of TB analytes. However, the conventional ELISA method only shows tonal colors that need a high concentration of analyte to achieve high confidence levels for naked eye detection. Also, in this research, we proposed the incorporation of protein biomarker, Mycobacterium tuberculosis ESAT-6-like protein esxB (CFP-10), as a means of TB detection using plasmonic ELISA. With the use of this technique, the CFP-10 detection limit can be lowered to 0.01 µg/mL by the naked eye. Further, our developed technique was successfully tested and confirmed with sputum samples from patients diagnosed with positive TB, thereby providing enough evidence for the utilization of our technique in the early diagnosis of TB disease.

  9. Two-Laser Interference Visible to the Naked Eye

    ERIC Educational Resources Information Center

    Kawalec, Tomasz; Bartoszek-Bober, Dobroslawa

    2012-01-01

    An experimental setup allowing the observation of two-laser interference by the naked eye is described. The key concept is the use of an electronic phase lock between two external cavity diode lasers. The experiment is suitable both for undergraduate and graduate students, mainly in atomic physics laboratories. It gives an opportunity for…

  10. A Cyanine Dye Encapsulated Porous Fibrous Mat for Naked-Eye Ammonia Sensing.

    PubMed

    Ji, Chendong; Ma, Lijing; Yin, Meizhen; Yang, Wantai; Pan, Kai

    2016-08-19

    Electrospun ultrathin fiber-based sensors are desirable because of their practicality and sensitivity. Ammonia-detection systems are in high demand in different areas, including the industrial and agricultural fields. However, current technologies rely on large and complex instruments that restrict their actual utilization. Herein, we report a flexible naked-eye ammonia sensor, the polylactic acid-cyanine (PLA-Cy) fibrous mat, which was fabricated by blending a carboxyl-functionalized cyanine dye (D1) into electospun PLA porous fibers. The sensing mat was shown to undergo a naked-eye-detectable color change from white to blue upon exposure to ammonia vapor. The mat showed high selectivity to ammonia gas with a detection limit of 3.3 ppm. Aggregated D1 was first encapsulated by PLA and was then ionized by NH3 . These mechanisms were examined by photophysical studies and scanning electron microscopy. The aggregation-deaggregation process of D1 in the PLA-Cy fibrous mat led to the color change. This work provides a facile method for the naked-eye detection of ammonia and a novel strategy for the use of organic dyes in ammonia sensing. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. The value of naked eye examination of biopsied lymph nodes in the diagnosis of tuberculous lymphadenitis.

    PubMed

    Bem, C

    1996-01-01

    Tuberculous lymphadenitis is common in Central Africa, where diagnosis by histological examination of a biopsied node is often delayed. In the present study, the naked eye appearance of the cut surface of 306 consecutive biopsied lymph nodes was compared with the histological diagnosis. One hundred and eight-eight nodes showed tuberculosis on histology (including two with coexisting second pathology). One hundred and forty-eight (79%) cases of tuberculous lymphadenitis (including both with coexisting second pathology) showed noncaseating tuberculomata or caseation visible on naked eye examination. Such signs were not seen in other nodes. Other signs were seen in another 18 (10%) tuberculous nodes. It is concluded that naked eye examination of nodes provides useful information for the diagnosis of tuberculous lymphadenitis, pending confirmation by histology.

  12. Examination of the cervix with the naked eye using acetic acid test.

    PubMed

    Ottaviano, M; La Torre, P

    1982-05-15

    Examination of the cervix was carried out on 2,400 patients, by use of acetic acid test with the naked eye and the colposcope. The physiologic transformation zone was clearly identified both with the naked eye and the colposcope in 1,568 of 1,594 (99%) cases. Colposcopic examination was unsatisfactory in 108 of the 264 (41%) patients in whom the cervix was completely covered by normal squamous epithelium. An atypical transformation zone (ATZ) was identified with the naked eye as white epithelium in 98.4% and as "suspicious" in 1.6% of 312 colposcopically controlled cases. An unsatisfactory colposcopic examination occurred in 39 of the 312 (12.5%) patients with an ATZ. Final histologic diagnosis for 312 ATZs was benign lesion in 169 of 312 (54.2%), cervical intraepithelial neoplasia (CIN) grades 1 and 2 in 81 of 312 (26%), grade 3 CIN in 56 of 312 (17.9%), and preclinical invasive carcinoma in 6 of 312 (1.9%). The detection of intraepithelial or preclinical invasive cervical neoplasias should not depend on the possession of a colposcope. On the other hand, the use of a colposcope is essential for the selection of CIN that can be treated with ultraconservative therapy or with colposcopically directed conization.

  13. Back to basics: naked-eye astronomical observation

    NASA Astrophysics Data System (ADS)

    Barclay, Charles

    2003-09-01

    For pupils of both sexes and all ages from about six upwards, the subject of Astronomy holds many fascinations - the rapid changes in knowledge, the large resource of available IT packages and above all the beautiful pictures from Hubble and the large Earth-based telescopes. This article, however, stresses the excitement and importance of naked-eye (unaided) first-hand observation, where light pollution allows, and suggests some techniques that may be used to enthuse and introduce youngsters to the glory of the night sky without recourse to computer screens.

  14. Phage-mediated counting by the naked eye of miRNA molecules at attomolar concentrations in a Petri dish.

    PubMed

    Zhou, Xin; Cao, Peng; Zhu, Ye; Lu, Wuguang; Gu, Ning; Mao, Chuanbin

    2015-10-01

    The ability to count biomolecules such as cancer-biomarker miRNAs with the naked eye is seemingly impossible in molecular diagnostics. Here, we show an ultrasensitive naked-eye-counting strategy for quantifying miRNAs by employing T7 phage-a bacteria-specific virus nanoparticle-as a surrogate. The phage is genetically engineered to become fluorescent and capable of binding a miRNA-capturing gold nanoparticle (GNP) in a one-to-one manner. Target miRNAs crosslink the resultant phage-GNP couple and miRNA-capturing magnetic microparticles, forming a sandwich complex containing equimolar phage and miRNA. The phage is then released from the complex and developed into one macroscopic fluorescent plaque in a Petri dish by plating it in a host bacterial medium. Counting the plaques by the naked eye enables the quantification of miRNAs with detection limits of ∼3 and ∼5 aM for single-target and two-target miRNAs, respectively. This approach offers ultrasensitive and convenient quantification of disease biomarkers by the naked eye.

  15. Phage-mediated counting by the naked eye of miRNA molecules at attomolar concentrations in a Petri dish

    NASA Astrophysics Data System (ADS)

    Zhou, Xin; Cao, Peng; Zhu, Ye; Lu, Wuguang; Gu, Ning; Mao, Chuanbin

    2015-10-01

    The ability to count biomolecules such as cancer-biomarker miRNAs with the naked eye is seemingly impossible in molecular diagnostics. Here, we show an ultrasensitive naked-eye-counting strategy for quantifying miRNAs by employing T7 phage--a bacteria-specific virus nanoparticle--as a surrogate. The phage is genetically engineered to become fluorescent and capable of binding a miRNA-capturing gold nanoparticle (GNP) in a one-to-one manner. Target miRNAs crosslink the resultant phage-GNP couple and miRNA-capturing magnetic microparticles, forming a sandwich complex containing equimolar phage and miRNA. The phage is then released from the complex and developed into one macroscopic fluorescent plaque in a Petri dish by plating it in a host bacterial medium. Counting the plaques by the naked eye enables the quantification of miRNAs with detection limits of ~3 and ~5 aM for single-target and two-target miRNAs, respectively. This approach offers ultrasensitive and convenient quantification of disease biomarkers by the naked eye.

  16. A naked eye refractive index sensor with a visible multiple peak metamaterial absorber.

    PubMed

    Ma, Heli; Song, Kun; Zhou, Liang; Zhao, Xiaopeng

    2015-03-26

    We report a naked eye refractive index sensor with a visible metamaterial absorber. The visible metamaterial absorber consisting of a silver dendritic/dielectric/metal structure shows multiple absorption peaks. By incorporating a gain material (rhodamine B) into the dielectric layer, the maximal magnitude of the absorption peak can be improved by about 30%. As the metamaterial absorber is sensitive to the refractive index of glucose solutions, it can function as a sensor that quickly responds to variations of the refractive index of the liquid. Meanwhile, since the response is presented via color changes, it can be clearly observed by the naked eyes. Further experiments have confirmed that the sensor can be used repeatedly.

  17. A paper-based cantilever array sensor: Monitoring volatile organic compounds with naked eye.

    PubMed

    Fraiwan, Arwa; Lee, Hankeun; Choi, Seokheun

    2016-09-01

    Volatile organic compound (VOC) detection is critical for controlling industrial and commercial emissions, environmental monitoring, and public health. Simple, portable, rapid and low-cost VOC sensing platforms offer the benefits of on-site and real-time monitoring anytime and anywhere. The best and most practically useful approaches to monitoring would include equipment-free and power-free detection by the naked eye. In this work, we created a novel, paper-based cantilever sensor array that allows simple and rapid naked-eye VOC detection without the need for power, electronics or readout interface/equipment. This simple VOC detection method was achieved using (i) low-cost paper materials as a substrate and (ii) swellable thin polymers adhered to the paper. Upon exposure to VOCs, the polymer swelling adhered to the paper-based cantilever, inducing mechanical deflection that generated a distinctive composite pattern of the deflection angles for a specific VOC. The angle is directly measured by the naked eye on a 3-D protractor printed on a paper facing the cantilevers. The generated angle patterns are subjected to statistical algorithms (linear discriminant analysis (LDA)) to classify each VOC sample and selectively detect a VOC. We classified four VOC samples with 100% accuracy using LDA. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. GRB 080319B: A Naked-Eye Stellar Blast from the Distant Universe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Racusin, J. L.; Burrows, D. N.

    On behalf of a large international collaboration [1], we present the unprecedented broadband observations of GRB 080319B, whose prompt optical emission peaked at a visual magnitude of 5.3, making it briefly visible with the naked eye. GRB 080319B was discovered by Swift and captured in exquisite detail by ground based wide-field telescopes, imaging the burst location from before the time of the explosion. The combination of these unique optical data with simultaneous {gamma}-ray observations provides powerful diagnostics of the detailed physics of this explosion within seconds of its formation. We show that the prompt optical and {gamma}-ray emissions from thismore » event arise from different spectral components within the same physical region located at a large distance from the source, implying an extremely relativistic outflow. Our observations also provide good evidence for a bright reverse shock component. The chromatic behavior of the broadband afterglow is consistent with viewing the GRB down the very narrow inner core of a two-component jet that is expanding into a wind-like environment consistent with the massive star origin of long GRBs.« less

  19. Optical effects related to Keplerian discs orbiting Kehagias-Sfetsos naked singularities

    NASA Astrophysics Data System (ADS)

    Stuchlík, Zdeněk; Schee, Jan

    2014-10-01

    We demonstrate possible optical signatures of the Kehagias-Sfetsos (KS) naked singularity spacetimes representing a spherically symmetric vacuum solution of the modified Hořava gravity. In such spacetimes, accretion structures significantly different from those present in standard black hole spacetimes occur due to the ‘antigravity’ effect, which causes an internal static sphere surrounded by Keplerian discs. We focus our attention on the optical effects related to the Keplerian accretion discs, constructing the optical appearance of the Keplerian discs, the spectral continuum due to their thermal radiation, and the spectral profiled lines generated in the innermost parts of such discs. The KS naked singularity signature is strongly encoded in the characteristics of predicted optical effects, especially in cases where the spectral continuum and spectral lines are profiled by the strong gravity of the spacetimes due to the vanishing region of the angular velocity gradient influencing the effectiveness of the viscosity mechanism. We can conclude that optical signatures of KS naked singularities can be well distinguished from the signatures of standard black holes.

  20. Novel cellulose-based halochromic test strips for naked-eye detection of alkaline vapors and analytes.

    PubMed

    Abou-Yousef, Hussein; Khattab, Tawfik A; Youssef, Yehia A; Al-Balakocy, Naser; Kamel, Samir

    2017-08-01

    A simple, portable and highly sensitive naked-eye test strip is successfully prepared for optical detection of gaseous and aqueous alkaline analytes. Novel pH-sensory tricyanofuran-hydrazone (TCFH) disperse colorant containing a hydrazone recognition functional moiety is successfully synthesized via azo-coupling reaction between active methyl-containing tricyanofuran (TCF) heterocycle and diazonium salt of 4-aminobenzaldehyde followed by Knoevenagel condensation with malononitrile. UV-vis absorption spectra display solvatochromism and reversible color changes of the TCFH solution in dimethyl sulfoxide in response to pH variations. We investigate the preparation of hydrophobic cellulose/polyethylene terephthalate composites characterized by their high affinity for disperse dyes. Composite films made from CA, Cell/CA, PET/CA, and Cell/PET-CA are produced via solvent-casting procedure using 10-30% modified cellulose or modified polyethylene terephthalate. The mechanical properties and morphologies of these composite films are investigated. The prepared pH-sensory hydrazone-based disperse dye is then applied to dye the produced cellulose-based composite films employing the high temperature pressure dyeing procedure. The produced halochromic PET-CA-TCFH test strip provide an instant visible signal from orange to purple upon exposure to alkaline conditions as proved by the coloration measurements. The sensor strip exhibits high sensitivity and quick detection toward ammonia in both of aqueous and vapor phases by naked-eye observations at room temperature and atmospheric pressure. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Naked-eye sensor for rapid determination of mercury ion.

    PubMed

    Liu, Jing; Wu, Dapeng; Yan, Xiaohui; Guan, Yafeng

    2013-11-15

    A naked-eye paper sensor for rapid determination of trace mercury ion in water samples was designed and demonstrated. The mercury-sensing rhodamine B thiolactone was immobilized in silica matrices and the silica matrices were impregnated firmly and uniformly in the filter paper. As water samples flow through the filter paper, the membrane color will change from white to purple red, which could be observed obviously with naked eye, when concentration of mercury ions equals to or exceeds 10nM, the maximum residue level in drinking water recommended by U.S. EPA. The color change can also be recorded by a flatbed scanner and then digitized, reducing the detection limit of Hg(2+) down to 1.2 nM. Moreover, this method is extremely specific for Hg(2+) and shows a high tolerance ratio of interferent coexisting ions. The presence of Na(+) (2 mM), K(+) (2 mM), Fe(3+) (0.1 mM), Zn(2+) (0.1 mM), Mg(2+) (0.1 mM), Ni(2+) (50 μM), Co(2+) (50 μM), Cd(2+) (50 μM), Pb(2+) (50 μM), Cu(2+) (50 μM) and Ag(+) (3.5 μM) did not interfere with the detection of Hg(2+) (25 nM). Finally, the present method was applied in the detection of Hg(2+) in mineral water, tap water and pond water. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Plasmonic ELISA for the ultrasensitive detection of disease biomarkers with the naked eye

    NASA Astrophysics Data System (ADS)

    de La Rica, Roberto; Stevens, Molly M.

    2012-12-01

    In resource-constrained countries, affordable methodologies for the detection of disease biomarkers at ultralow concentrations can potentially improve the standard of living. However, current strategies for ultrasensitive detection often require sophisticated instruments that may not be available in laboratories with fewer resources. Here, we circumvent this problem by introducing a signal generation mechanism for biosensing that enables the detection of a few molecules of analyte with the naked eye. The enzyme label of an enzyme-linked immunosorbent assay (ELISA) controls the growth of gold nanoparticles and generates coloured solutions with distinct tonality when the analyte is present. Prostate specific antigen (PSA) and HIV-1 capsid antigen p24 were detected in whole serum at the ultralow concentration of 1 × 10-18 g ml-1. p24 was also detected with the naked eye in the sera of HIV-infected patients showing viral loads undetectable by a gold standard nucleic acid-based test.

  3. Phototoxic effects of commercial photographic flash lamp on rat eyes.

    PubMed

    Inoue, Makoto; Shinoda, Kei; Ohde, Hisao; Tezuka, Keiji; Hida, Tetsuo

    2006-11-01

    To determine whether exposure of the cornea and retina of rats to flashes from a commercial photographic flash lamp is phototoxic. Sprague-Dawley rats were exposed to 10, 100, or 1,000 flashes of the OPTICAM 16M photographic flash lamp (Fujikoeki, Japan) placed 0.1, 1, or 3 m from the eyes. Corneal damage was assessed by a fluorescein staining score, and the retinal damage by eletroretinography (ERG) and histology before and 24 h after exposure. Exposure of the eyes to 1,000 flashes at 0.1 m increased the fluorescein staining score significantly (P = 0.009, the Mann-Whitney test). Scanning electron microscopy (SEM) of the cornea showed a detachment of the epithelial cells from the surface after this exposure. The amplitude of the a-wave was decreased significantly by 23.0% (P = 0.026) of the amplitude before the exposure, and the b-wave by 19.7% (P = 0.0478) following 1,000 flashes at 0.1 m but not by the other exposures. TUNEL-positive cells were present in the outer nuclear layer only after the extreme exposure, but no significant decrease in retinal thickness was seen under any condition. The fluorescein staining score and ERGs recovered to control levels within 1 week. Light exposure to a photographic flash lamp does not induce damage to the cornea and retina except when they are exposed to 1,000 flashes at 0.1 m.

  4. Naked eye detection of mutagenic DNA photodimers using gold nanoparticles.

    PubMed

    Kim, Joong Hyun; Chung, Bong Hyun

    2011-01-15

    We developed a method to detect mutagenic DNA photodimers by the naked eye using gold nanoparticles. The stability of gold nanoparticles in a high ionic strength solution is maintained by straight ssDNA adsorbed physically on the AuNPs. However, we found that UV-irradiated DNA was less adsorptive onto gold nanoparticles because of a conformational change of UV-irradiated DNA. The accumulated deformation of the DNA structure by multiple-dimer formation triggered aggregation of the gold nanoparticles mixed with the UV-irradiated DNA and thus red to purple color changes of the mixture, which allowed colorimetric detection of the DNA photodimers by the naked eye. No fragmented mass and reactive oxygen species production under the UVB irradiation confirmed that the aggregation of gold nanoparticles was solely attributed to the accumulated deformation of the UV irradiated DNA. The degree of gold nanoparticles-aggregation was dependent on the UVB irradiated time and base compositions of the UV-irradiated oligonucleotides. In addition, we successfully demonstrated how to visually qualify the photosensitizing effect of chemical compounds in parallel within only 10 min by applying this new method. Since our method does not require any chemical or biochemical treatments or special instruments for purifying and qualifying the DNA photolesions, it should provide a feasible tool for the studies of the UV-induced mutagenic or carcinogenic DNA dimers and accelerate screening of a large number of drug candidates. Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.

  5. Naked-eye fingerprinting of single nucleotide polymorphisms on psoriasis patients

    NASA Astrophysics Data System (ADS)

    Valentini, Paola; Marsella, Alessandra; Tarantino, Paolo; Mauro, Salvatore; Baglietto, Silvia; Congedo, Maurizio; Paolo Pompa, Pier

    2016-05-01

    We report a low-cost test, based on gold nanoparticles, for the colorimetric (naked-eye) fingerprinting of a panel of single nucleotide polymorphisms (SNPs), relevant for the personalized therapy of psoriasis. Such pharmacogenomic tests are not routinely performed on psoriasis patients, due to the high cost of standard technologies. We demonstrated high sensitivity and specificity of our colorimetric test by validating it on a cohort of 30 patients, through a double-blind comparison with two state-of-the-art instrumental techniques, namely reverse dot blotting and sequencing, finding 100% agreement. This test offers high parallelization capabilities and can be easily generalized to other SNPs of clinical relevance, finding broad utility in diagnostics and pharmacogenomics.We report a low-cost test, based on gold nanoparticles, for the colorimetric (naked-eye) fingerprinting of a panel of single nucleotide polymorphisms (SNPs), relevant for the personalized therapy of psoriasis. Such pharmacogenomic tests are not routinely performed on psoriasis patients, due to the high cost of standard technologies. We demonstrated high sensitivity and specificity of our colorimetric test by validating it on a cohort of 30 patients, through a double-blind comparison with two state-of-the-art instrumental techniques, namely reverse dot blotting and sequencing, finding 100% agreement. This test offers high parallelization capabilities and can be easily generalized to other SNPs of clinical relevance, finding broad utility in diagnostics and pharmacogenomics. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr02200f

  6. One-step detection of pathogens and cancer biomarkers by the naked eye based on aggregation of immunomagnetic beads

    NASA Astrophysics Data System (ADS)

    Chen, Yiping; Xianyu, Yunlei; Sun, Jiashu; Niu, Yajing; Wang, Yu; Jiang, Xingyu

    2015-12-01

    This report shows that immunomagnetic beads (IMBs) can act as the optical readout for assays, in addition to serving as the carrier for purification/separation. Under the influence of an external magnet, IMBs are attracted to coat one side of a test tube. IMBs specifically bound to targets can form a narrow brown stripe, whereas free IMBs will form a diffuse, yellow coating on the side of the test tube. Target analytes can aggregate initially dispersed IMBs in a sample concentration-dependent manner, yielding a color change from yellow to brown that can be seen with the naked eye. This assay combines the convenience of a lateral flow assay, allowing a one-step assay to finish within 15 min, with the sensitivity of an enzyme-linked immonosorbent assay.This report shows that immunomagnetic beads (IMBs) can act as the optical readout for assays, in addition to serving as the carrier for purification/separation. Under the influence of an external magnet, IMBs are attracted to coat one side of a test tube. IMBs specifically bound to targets can form a narrow brown stripe, whereas free IMBs will form a diffuse, yellow coating on the side of the test tube. Target analytes can aggregate initially dispersed IMBs in a sample concentration-dependent manner, yielding a color change from yellow to brown that can be seen with the naked eye. This assay combines the convenience of a lateral flow assay, allowing a one-step assay to finish within 15 min, with the sensitivity of an enzyme-linked immonosorbent assay. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07044a

  7. Electro-optical muzzle flash detection

    NASA Astrophysics Data System (ADS)

    Krieg, Jürgen; Eisele, Christian; Seiffer, Dirk

    2016-10-01

    Localizing a shooter in a complex scenario is a difficult task. Acoustic sensors can be used to detect blast waves. Radar technology permits detection of the projectile. A third method is to detect the muzzle flash using electro-optical devices. Detection of muzzle flash events is possible with focal plane arrays, line and single element detectors. In this paper, we will show that the detection of a muzzle flash works well in the shortwave infrared spectral range. Important for the acceptance of an operational warning system in daily use is a very low false alarm rate. Using data from a detector with a high sampling rate the temporal signature of a potential muzzle flash event can be analyzed and the false alarm rate can be reduced. Another important issue is the realization of an omnidirectional view required on an operational level. It will be shown that a combination of single element detectors and simple optics in an appropriate configuration is a capable solution.

  8. Rapid micromotor-based naked-eye immunoassay.

    PubMed

    de Ávila, Berta Esteban-Fernández; Zhao, Mingjiao; Campuzano, Susana; Ricci, Francesco; Pingarrón, José M; Mascini, Marcello; Wang, Joseph

    2017-05-15

    A dynamic micromotor-based immunoassay, exemplified by cortisol detection, based on the use of tubular micromotors functionalized with a specific antibody is described. The use of antibody-functionalized micromotors offers huge acceleration of both direct and competitive cortisol immunoassays, along with greatly enhanced sensitivity of direct and competitive immunoassays. The dramatically improved speed and sensitivity reflect the greatly increased likelihood of antibody-cortisol contacts and fluid mixing associated with the dynamic movement of these microtube motors and corresponding bubble generation that lead to a highly efficient and rapid recognition process. Rapid naked-eye detection of cortisol in the sample is achieved in connection to use of horseradish peroxidase (HRP) tag and TMB/H 2 O 2 system. Key parameters of the competitive immunoassay (e.g., incubation time and reaction volume) were optimized. This fast visual micromotor-based sensing approach enables "on the move" specific detection of the target cortisol down to 0.1μgmL -1 in just 2min, using ultrasmall (50µL) sample volumes. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Eye light flashes on the Mir space station.

    PubMed

    Avdeev, S; Bidoli, V; Casolino, M; De Grandis, E; Furano, G; Morselli, A; Narici, L; De Pascale, M P; Picozza, P; Reali, E; Sparvoli, R; Boezio, M; Carlson, P; Bonvicini, W; Vacchi, A; Zampa, N; Castellini, G; Fuglesang, C; Galper, A; Khodarovich, A; Ozerov, Yu; Popov, A; Vavilov, N; Mazzenga, G; Ricci, M; Sannita, W G; Spillantini, P

    2002-04-01

    The phenomenon of light flashes (LF) in eyes for people in space has been investigated onboard Mir. Data on particles hitting the eye have been collected with the SilEye detectors, and correlated with human observations. It is found that a nucleus in the radiation environment of Mir has roughly a 1% probability to cause an LF, whereas the proton probability is almost three orders of magnitude less. As a function of LET, the LF probability increases above 10 keV/micrometer, reaching about 5% at around 50 keV/micrometer. c 2002 Elsevier Science Ltd. All rights reserved.

  10. Naked eye determination of the dawn for Sinai and Assiut of Egypt

    NASA Astrophysics Data System (ADS)

    Hassan, A. H.; Issa, I. A.; Mousa, M.; Abdel-Hadi, Yasser A.

    2016-06-01

    Twilight observations were carried out by naked eye in the period (2010-2012) for north Sinai (Lat. 31°4‧N, Long. 32°52‧E) where the background is desert, and for Assiut (Lat. 27°10‧N, Long. 31°10‧E) in the period (2012-2014) where the background is agricultural land. The purpose of these observations is to calculate the depression of the sun below the horizon at which the normal eye can discriminate the dawn (morning white thread) for two sites. The results indicated that this discrimination takes place at vertical sun depression angles, Do = 14.61° and 13.665° at Sinai and Assiut respectively.

  11. [Impacts of rotating or lifting-thrusting manipulation on distant vision of naked eye in patients of juvenile myopia: a randomized controlled trial].

    PubMed

    Tao, Xiao-Yan; Zhao, Bai-Yiao; Han, Xiao; Dong, Xiao-Yu; Yan, An; Ren, Xu-Ru; Liu, Yan-Wen; Qu, Chang; Xia, Shu-Fen; Yang, Jia-Le

    2014-05-01

    To compare the differences in the efficacy on distant version of naked eye in the patients of juvenile myopia between rotating manipulation and lifting-thrusting manipulation of acupuncture. One hundred and twenty cases (240 eyes) were randomized into a rotating manipulation group and a lifting-thrusting manipulation group, 60 cases (120 eyes) in each group. Additionally, a corrective lenses group, 60 cases (120 eyes), was set up as the control. In both manipulation groups, Cuanzhu (BL 2),Yuyao (EX-HN 4), Sizhukong (TE 23), Taiyang (EX-HN 5), Fengchi (GB 20), Zusanli (ST 36), Guangming (GB 37) and Sanyinjiao (SP 6) were punctured, but stimulated with rotating manipulation and lifting-thrusting manipulation respectively three times per week, 10 times as a treatment session and totally one session was required. In the corrective lenses group, the glasses were applied at daytime. The clinical efficacy and the changes in distant vision of naked eye before and after treatment were compared among the three groups. The total effective rate was 87.5% (105/120) in the rotating manipulation group, which was better than 69.2% (83/120) in the lifting-thrusting manipulation group (P < 0.05). The distant vision of naked eye was improved apparently in the rotating manipulation group and the lifting-thrusting manipulation group after treatment (both P < 0.05). But it was not improved in the corrective lenses group (P > 0.05). The distant vision of naked eye was improved more apparently after treatment in the rotating manipulation group as compared with that in the lifting-thrusting manipulation group (0.75 +/- 0.23 vs 0.68 +/- 0.24, P < 0.05). For 96 cases (192 eyes) with acupuncture treatment, in 3-month follow-up, 87.0% (167/192) of the cases maintained the stable vision as the original level and 13.0% (25/192) of them were reduced in the vision In the acupuncture groups, it was found that the improvement of distant vision of naked eye was more obvious after treatment with

  12. A naked-eye colorimetric "PCR developer"

    NASA Astrophysics Data System (ADS)

    Valentini, Paola; Pompa, Pier Paolo

    2016-04-01

    Despite several advances in molecular biology and diagnostics, Polymerase Chain Reaction (PCR) is currently the gold standard for nucleic acids amplification and detection, due to its versatility, low-cost and universality, with estimated <10 billion reactions per year and a worldwide market of several billion dollars/year. Nevertheless, PCR still relies on the laborious, time-consuming, and multi-step gel electrophoresis-based detection, which includes gel casting, electrophoretic run, gel staining, and gel visualization. In this work, we propose a "PCR developer", namely a universal one-step, one-tube method, based on controlled aggregation of gold nanoparticles (AuNPs), to detect PCR products by naked eye in few minutes, with no need for any instrumentation. We demonstrated the specificity and sensitivity of the PCR developer on different model targets, suitable for a qualitative detection in real-world diagnostics (i.e., gene rearrangements, genetically modified organisms, and pathogens). The PCR developer proved to be highly specific and ultra-sensitive, discriminating down to few copies of HIV viral DNA, diluted in an excess of interfering human genomic DNA, which is a clinically relevant viral load. Hence, it could be a valuable tool for both academic research and clinical applications.

  13. The properties of optical lightning flashes and the clouds they illuminate

    NASA Astrophysics Data System (ADS)

    Peterson, Michael; Deierling, Wiebke; Liu, Chuntao; Mach, Douglas; Kalb, Christina

    2017-01-01

    Optical lightning sensors like the Optical Transient Detector and Lightning Imaging Sensor (LIS) measure total lightning across large swaths of the globe with high detection efficiency. With two upcoming missions that employ these sensors - LIS on the International Space Station and the Geostationary Lightning Mapper on the GOES-R satellite - there has been increased interest in what these measurements can reveal about lightning and thunderstorms in addition to total flash activity. Optical lightning imagers are capable of observing the characteristics of individual flashes that include their sizes, durations, and radiative energies. However, it is important to exercise caution when interpreting trends in optical flash measurements because they can be affected by the scene. This study uses coincident measurements from the Tropical Rainfall Measuring Mission (TRMM) satellite to examine the properties of LIS flashes and the surrounding cloud regions they illuminate. These combined measurements are used to assess to what extent optical flash characteristics can be used to make inferences about flash structure and energetics. Clouds illuminated by lightning over land and ocean regions that are otherwise similar based on TRMM measurements are identified. Even when LIS flashes occur in similar clouds and background radiances, oceanic flashes are still shown to be larger, brighter, longer lasting, more prone to horizontal propagation, and to contain more groups than their land-based counterparts. This suggests that the optical trends noted in literature are not entirely the result of radiative transfer effects but rather stem from physical differences in the flashes.

  14. Seeing Beyond the Naked Eye in a Planetarium

    NASA Astrophysics Data System (ADS)

    Fairall, A.

    2005-12-01

    I have a philosophy that the traditional naked-eye sky, as usually shown in planetariums, should only be an introductory step in portraying the Universe. Consequently, over the years I have produced 'inter alia' various versions of an enhanced Milky Way (the latest based on Axel Mellenger's panorama), the extragalactic sky and the radio sky for projection on planetarium domes. I also put together a three-dimensional planetarium show-the audience being equipped with ChromDepth(tm) spectacles- which stepped from the Solar System to the cosmic microwave background. The advent of digital technology now makes all this much easier. Currently, Labyrinth, a visualization program developed in-house, serves much the same function as the Hayden Planetarium's Partiview, but also permits rendering and fl y-throughs of large-scale structures. It allows viewers to explore local cosmography. Labyrinth can produce images that operate with the 3-D spectacles; we have also produced a version of Partiview that does the same.

  15. The Evolution and Structure of Extreme Optical Lightning Flashes.

    PubMed

    Peterson, Michael; Rudlosky, Scott; Deierling, Wiebke

    2017-12-27

    This study documents the composition, morphology, and motion of extreme optical lightning flashes observed by the Lightning Imaging Sensor (LIS). The furthest separation of LIS events (groups) in any flash is 135 km (89 km), the flash with the largest footprint had an illuminated area of 10,604 km 2 , and the most dendritic flash has 234 visible branches. The longest-duration convective LIS flash lasted 28 s and is overgrouped and not physical. The longest-duration convective-to-stratiform propagating flash lasted 7.4 s, while the longest-duration entirely stratiform flash lasted 4.3 s. The longest series of nearly consecutive groups in time lasted 242 ms. The most radiant recorded LIS group (i.e., "superbolt") is 735 times more radiant than the average group. Factors that impact these optical measures of flash morphology and evolution are discussed. While it is apparent that LIS can record the horizontal development of the lightning channel in some cases, radiative transfer within the cloud limits the flash extent and level of detail measured from orbit. These analyses nonetheless suggest that lightning imagers such as LIS and Geostationary Lightning Mapper can complement ground-based lightning locating systems for studying physical lightning phenomena across large geospatial domains.

  16. The Evolution and Structure of Extreme Optical Lightning Flashes

    PubMed Central

    Peterson, Michael; Rudlosky, Scott; Deierling, Wiebke

    2018-01-01

    This study documents the composition, morphology, and motion of extreme optical lightning flashes observed by the Lightning Imaging Sensor (LIS). The furthest separation of LIS events (groups) in any flash is 135 km (89 km), the flash with the largest footprint had an illuminated area of 10,604 km2, and the most dendritic flash has 234 visible branches. The longest-duration convective LIS flash lasted 28 s and is overgrouped and not physical. The longest-duration convective-to-stratiform propagating flash lasted 7.4 s, while the longest-duration entirely stratiform flash lasted 4.3 s. The longest series of nearly consecutive groups in time lasted 242 ms. The most radiant recorded LIS group (i.e., “superbolt”) is 735 times more radiant than the average group. Factors that impact these optical measures of flash morphology and evolution are discussed. While it is apparent that LIS can record the horizontal development of the lightning channel in some cases, radiative transfer within the cloud limits the flash extent and level of detail measured from orbit. These analyses nonetheless suggest that lightning imagers such as LIS and Geostationary Lightning Mapper can complement ground-based lightning locating systems for studying physical lightning phenomena across large geospatial domains. PMID:29527425

  17. Interaction of Thermus thermophilus, ArsC enzyme and gold nanoparticles naked-eye assays speciation between As(III) and As(V)

    NASA Astrophysics Data System (ADS)

    Politi, Jane; Spadavecchia, Jolanda; Fiorentino, Gabriella; Antonucci, Immacolata; Casale, Sandra; De Stefano, Luca

    2015-10-01

    The thermophilic bacterium Thermus thermophilus HB27 encodes chromosomal arsenate reductase (TtArsC), the enzyme responsible for resistance to the harmful effects of arsenic. We report on adsorption of TtArsC onto gold nanoparticles for naked-eye monitoring of biomolecular interaction between the enzyme and arsenic species. Synthesis of hybrid biological-metallic nanoparticles has been characterized by transmission electron microscopy (TEM), ultraviolet-visible (UV-vis), dynamic light scattering (DLS) and phase modulated infrared reflection absorption (PM-IRRAS) spectroscopies. Molecular interactions have been monitored by UV-vis and Fourier transform-surface plasmon resonance (FT-SPR). Due to the nanoparticles’ aggregation on exposure to metal salts, pentavalent and trivalent arsenic solutions can be clearly distinguished by naked-eye assay, even at 85 μM concentration. Moreover, the assay shows partial selectivity against other heavy metals.

  18. Dew inspired breathing-based detection of genetic point mutation visualized by naked eye

    PubMed Central

    Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan

    2014-01-01

    A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions. PMID:25199907

  19. Dew inspired breathing-based detection of genetic point mutation visualized by naked eye

    NASA Astrophysics Data System (ADS)

    Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan

    2014-09-01

    A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions.

  20. Dew inspired breathing-based detection of genetic point mutation visualized by naked eye.

    PubMed

    Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan

    2014-09-09

    A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions.

  1. Honeywell optical investigations on FLASH program

    NASA Astrophysics Data System (ADS)

    O'Rourke, Ken; Peterson, Eric; Yount, Larry

    1995-05-01

    The increasing performance and reduction of life cycle cost requirements placed on commercial and military transport aircraft are resulting in more complex, highly integrated aircraft control and management systems. The use of fiber optic data transmission media can make significant contributions in achieving these performance and cost goals. The Honeywell portion of Task 2A on the Fly-by-Light Advanced System Hardware (FLASH) program is evaluating a Primary Flight Control System (PFCS) using pilot and copilot inputs from Active Hand Controllers (AHC) which are optically linked to the primary flight Control Computers (PFCC). Customer involvement is an important element of the Task 2A activity. Establishing customer requirements and perspectives on productization of systems developed under FLASH are key to future product success. The Honeywell elements of the PFCS demonstrator provide a command path that is optically interfaced from crew inputs to commands of distributed, smart actuation subsystems commands. Optical communication architectures are implemented using several protocols including the new AS-1773A 20 Mbps data bus standard. The interconnecting fiber optic cable plant is provided by our Task 1A teammate McDonnell Douglas Aerospace (West). Fiber optic cable plant fabrication uses processed, tools and materials reflecting necessary advances in manufacturing required to make fly-by-light avionics systems marketable.

  2. Naked eye instant reversible sensing of Cu(2+) and its in situ imaging in live brine shrimp Artemia.

    PubMed

    Nair, Ratish R; Raju, M; Patel, Neha P; Raval, Ishan H; Suresh, E; Haldar, Soumya; Chatterjee, Pabitra B

    2015-08-21

    A Cu(2+)-specific colorimetric reversible fluorescent receptor was designed and synthesized which showed a naked eye observable colour change from colourless to pink on addition of an aqueous buffer (pH 7.4) solution of 30 ppb Cu(2+). Short response time (≤5 s) and low detection limit (nearly 3 ppb) make suitable as a reliable "dip-in" open eye sensor for Cu(2+). Bio-imaging application in live brine shrimp Artemia enabled to detect Cu(2+) at as low as 10 ppb exposure.

  3. Role of Cerenkov radiation in the eye-flashes observed by Apollo astronauts.

    PubMed

    McNulty, P J; Pease, V P; Bond, V P

    1976-01-01

    Visual phenomena in the form of colorless flashes of light were observed by astronauts in deep space when their eyes were closed and adapted to darkness. We describe in this paper laboratory experiments and calculations which indicate that many of these flashes are the result of visible light generated within the astronauts' eyeball in the form of Cerenkov radiation when a relativistic HZE particle traverses it. The sensitivity to Cerenkov radiation measured for three subjects exposed to pulses of pions and muons and the visual phenomena observed were found to be consistent with the reports of flashes observed at rates as high as 2 per minute on Apollo missions 11 through 17.

  4. Large-area, uniform and low-cost dual-mode plasmonic naked-eye colorimetry and SERS sensor with handheld Raman spectrometer

    NASA Astrophysics Data System (ADS)

    Xu, Zhida; Jiang, Jing; Wang, Xinhao; Han, Kevin; Ameen, Abid; Khan, Ibrahim; Chang, Te-Wei; Liu, Gang Logan

    2016-03-01

    We demonstrated a highly-sensitive, wafer-scale, highly-uniform plasmonic nano-mushroom substrate based on plastic for naked-eye plasmonic colorimetry and surface-enhanced Raman spectroscopy (SERS). We gave it the name FlexBrite. The dual-mode functionality of FlexBrite allows for label-free qualitative analysis by SERS with an enhancement factor (EF) of 108 and label-free quantitative analysis by naked-eye colorimetry with a sensitivity of 611 nm RIU-1. The SERS EF of FlexBrite in the wet state was found to be 4.81 × 108, 7 times stronger than in the dry state, making FlexBrite suitable for aqueous environments such as microfluid systems. The label-free detection of biotin-streptavidin interaction by both SERS and colorimetry was demonstrated with FlexBrite. The detection of trace amounts of the narcotic drug methamphetamine in drinking water by SERS was implemented with a handheld Raman spectrometer and FlexBrite. This plastic-based dual-mode nano-mushroom substrate has the potential to be used as a sensing platform for easy and fast analysis in chemical and biological assays.We demonstrated a highly-sensitive, wafer-scale, highly-uniform plasmonic nano-mushroom substrate based on plastic for naked-eye plasmonic colorimetry and surface-enhanced Raman spectroscopy (SERS). We gave it the name FlexBrite. The dual-mode functionality of FlexBrite allows for label-free qualitative analysis by SERS with an enhancement factor (EF) of 108 and label-free quantitative analysis by naked-eye colorimetry with a sensitivity of 611 nm RIU-1. The SERS EF of FlexBrite in the wet state was found to be 4.81 × 108, 7 times stronger than in the dry state, making FlexBrite suitable for aqueous environments such as microfluid systems. The label-free detection of biotin-streptavidin interaction by both SERS and colorimetry was demonstrated with FlexBrite. The detection of trace amounts of the narcotic drug methamphetamine in drinking water by SERS was implemented with a handheld Raman

  5. PAIR-DOMINATED GeV-OPTICAL FLASH IN GRB 130427A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vurm, Indrek; Hascoët, Romain; Beloborodov, Andrei M., E-mail: indrek.vurm@gmail.com

    2014-07-10

    We show that the light curve of the double GeV+optical flash in GRB 130427A is consistent with radiation from the blast wave in a wind-type medium with density parameter A = ρr {sup 2} ∼ 5 × 10{sup 10} g cm{sup –1}. The peak of the flash is emitted by copious e {sup ±} pairs created and heated in the blast wave; our first-principle calculation determines the pair-loading factor and temperature of the shocked plasma. Using detailed radiative transfer simulations, we reconstruct the observed double flash. The optical flash is dominated by synchrotron emission from the thermal plasma behind the forward shock, andmore » the GeV flash is produced via inverse Compton (IC) scattering by the same plasma. The seed photons for IC scattering are dominated by the prompt MeV radiation during the first tens of seconds, and by the optical to X-ray afterglow thereafter. IC cooling of the thermal plasma behind the forward shock reproduces all GeV data from a few seconds to ∼1 day. We find that the blast wave Lorentz factor at the peak of the flash is Γ ≈ 200, and the forward shock magnetization is ε{sub B} ∼ 2 × 10{sup –4}. An additional source is required by the data in the optical and X-ray bands at times >10{sup 2} s; we speculate that this additional source may be a long-lived reverse shock in the explosion ejecta.« less

  6. Twilight observation by the naked eye of the dawn sincere at Hail and other areas in Saudi Arabia

    NASA Astrophysics Data System (ADS)

    Khalifa, N. S.; Hassan, A. H.; Taha, A. I.

    2018-06-01

    Naked eye observations of morning twilight phenomenon at Hail and other areas of Saudi Arabia are recorded. During the interval from 2014 to 2015, about 80 morning twilight observations were carried out in Hail at longitude λ = 41°42‧E and latitude φ = 27°31‧N for a desert background. The phenomena was followed over azimuth angles ranged from 0° to 20° of solar vertical direction and from 0° to 10° along the altitudinal range. By selecting 32 days with a very good visibility, it was found that Sun depression, Do, lies in a range between 13.48° and 14.69° with an average of 14.014° ±0.317. The difference between our obtained value and that one which is currently applicable in Saudi Arabia is about 4°. The results indicate that dawn (white thread browser) occurs at a sun vertical depression angle Do = 14.66° (mean + 2SD) according to the normal eye estimations. The results at different areas in the deep desert in KSA showed that the beginning of morning twilight and true dawn is at sun vertical depression Do = 14.88° (mean + 1SD). The current study shows significant results, which are comparable with both naked eye observations and photoelectric measurements of true dawn in both Egypt and Libya for desert background.

  7. C-H oxidation and chelation of a dipyrromethane mediated rapid colorimetric naked-eye Cu(ii) chemosensor.

    PubMed

    Rajmohan, Rajamani; Ayaz Ahmed, Khan Behlol; Sangeetha, Sampathkumar; Anbazhagan, Veerappan; Vairaprakash, Pothiappan

    2017-09-08

    Copper(ii) ion mediated C-H oxidation of dipyrromethanes (DPMs) to the corresponding dipyrrins followed by complexation invoked the selective sensing of copper(ii) ions in aqueous solutions. On the addition of copper, the colour of the DPM solution instantaneously changes from yellow to pink with the detection limit of 0.104 μM measured by absorption spectroscopy, whereas visible colour changes could be observed by the naked eye for concentrations as low as 3 μM.

  8. Large-area, uniform and low-cost dual-mode plasmonic naked-eye colorimetry and SERS sensor with handheld Raman spectrometer.

    PubMed

    Xu, Zhida; Jiang, Jing; Wang, Xinhao; Han, Kevin; Ameen, Abid; Khan, Ibrahim; Chang, Te-Wei; Liu, Gang Logan

    2016-03-21

    We demonstrated a highly-sensitive, wafer-scale, highly-uniform plasmonic nano-mushroom substrate based on plastic for naked-eye plasmonic colorimetry and surface-enhanced Raman spectroscopy (SERS). We gave it the name FlexBrite. The dual-mode functionality of FlexBrite allows for label-free qualitative analysis by SERS with an enhancement factor (EF) of 10(8) and label-free quantitative analysis by naked-eye colorimetry with a sensitivity of 611 nm RIU(-1). The SERS EF of FlexBrite in the wet state was found to be 4.81 × 10(8), 7 times stronger than in the dry state, making FlexBrite suitable for aqueous environments such as microfluid systems. The label-free detection of biotin-streptavidin interaction by both SERS and colorimetry was demonstrated with FlexBrite. The detection of trace amounts of the narcotic drug methamphetamine in drinking water by SERS was implemented with a handheld Raman spectrometer and FlexBrite. This plastic-based dual-mode nano-mushroom substrate has the potential to be used as a sensing platform for easy and fast analysis in chemical and biological assays.

  9. Electrochromic Asymmetric Supercapacitor Windows Enable Direct Determination of Energy Status by the Naked Eye.

    PubMed

    Zhong, Ying; Chai, Zhisheng; Liang, Zhimin; Sun, Peng; Xie, Weiguang; Zhao, Chuanxi; Mai, Wenjie

    2017-10-04

    Because of the popularity of smart electronics, multifunctional energy storage devices, especially electrochromic supercapacitors (SCs), have attracted tremendous research interest. Herein, a solid-state electrochromic asymmetric SC (ASC) window is designed and fabricated by introducing WO 3 and polyaniline as the negative and positive electrodes, respectively. The two complementary materials contribute to the outstanding electrochemical and electrochromic performances of the fabricated device. With an operating voltage window of 1.4 V and an areal capacitance of 28.3 mF cm -2 , the electrochromic devices show a high energy density of 7.7 × 10 -3 mW h cm -2 . Meanwhile, they exhibit an obvious and reversible color transition between light green (uncharged state) and dark blue (charged state), with an optical transmittance change between 55 and 12% at a wavelength of 633 nm. Hence, the energy storage level of the ASC is directly related to its color and can be determined by the naked eye, which means it can be incorporated with other energy cells to visual display their energy status. Particularly, a self-powered and color-indicated system is achieved by combining the smart windows with commercial solar cell panels. We believe that the novel electrochromic ASC windows will have great potential application for both smart electronics and smart buildings.

  10. A light-up probe with aggregation-induced emission characteristics (AIE) for selective imaging, naked-eye detection and photodynamic killing of Gram-positive bacteria.

    PubMed

    Feng, Guangxue; Yuan, Youyong; Fang, Hu; Zhang, Ruoyu; Xing, Bengang; Zhang, Guanxin; Zhang, Deqing; Liu, Bin

    2015-08-11

    We report the design and synthesis of a red fluorescent AIE light-up probe for selective recognition, naked-eye detection, and image-guided photodynamic killing of Gram-positive bacteria, including vancomycin-resistant Enterococcus strains.

  11. Highly Sensitive Naked-Eye Assay for Enterovirus 71 Detection Based on Catalytic Nanoparticle Aggregation and Immunomagnetic Amplification.

    PubMed

    Xiong, Ling-Hong; He, Xuewen; Xia, Junjie; Ma, Hanwu; Yang, Fan; Zhang, Qian; Huang, Dana; Chen, Long; Wu, Chunli; Zhang, Xiaomin; Zhao, Zheng; Wan, Chengsong; Zhang, Renli; Cheng, Jinquan

    2017-05-03

    Development of sensitive, convenient, and cost-effective virus detection product is of great significance to meet the growing demand of clinical diagnosis at the early stage of virus infection. Herein, a naked-eye readout of immunoassay by means of virion bridged catalase-mediated in situ reduction of gold ions and growth of nanoparticles, has been successfully proposed for rapid visual detection of Enterovirus 71 (EV71). Through tailoring the morphologies of the produced gold nanoparticles (GNPs) varying between dispersion and aggregation, a distinguishing color changing was ready for observation. This colorimetric detection assay, by further orchestrating the efficient magnetic enrichment and the high catalytic activity of enzyme, is managed to realize highly sensitive detection of EV71 virions with the limit of detection (LOD) down to 0.65 ng/mL. Our proposed method showed a much lower LOD value than the commercial ELISA for EV71 virion detection. Comparing to the current clinical gold standard polymerase chain reaction (PCR) method, our strategy provided the same diagnostic outcomes after testing real clinical samples. Besides, this strategy has no need of complicated sample pretreatment or expensive instruments. Our presented naked-eye immunoassay method holds a promising prospect for the early detection of virus-infectious disease especially in resource-constrained settings.

  12. Differences in the Optical Characteristics of Continental US Ground and Cloud Flashes as Observed from Space

    NASA Technical Reports Server (NTRS)

    Koshak, William

    2007-01-01

    Continental US lightning flashes observed by the Optical Transient Detector (OTD) are categorized according to flash type (ground or cloud flash) using US National Lightning Detection Network (TM) (NLDN) data. The statistics of the ground and cloud flash optical parameters (e.g., radiance, area, duration, number of optical groups, and number of optical events) are inter-compared. On average, the ground flash cloud-top emissions are more radiant, illuminate a larger area, are longer lasting, and have more optical groups and optical events than those cloud-top emissions associated with cloud flashes. Given these differences, it is suggested that the methods of Bayesian Inference could be used to help discriminate between ground and cloud flashes. The ability to discriminate flash type on-orbit is highly desired since such information would help researchers and operational decision makers better assess the intensification, evolutionary state, and severe weather potential of thunderstorms. This work supports risk reduction activities presently underway for the future launch of the GOES-R Geostationary Lightning Mapper (GLM).

  13. HUMAN EYE OPTICS: Determination of positions of optical elements of the human eye

    NASA Astrophysics Data System (ADS)

    Galetskii, S. O.; Cherezova, T. Yu

    2009-02-01

    An original method for noninvasive determining the positions of elements of intraocular optics is proposed. The analytic dependence of the measurement error on the optical-scheme parameters and the restriction in distance from the element being measured are determined within the framework of the method proposed. It is shown that the method can be efficiently used for determining the position of elements in the classical Gullstrand eye model and personalised eye models. The positions of six optical surfaces of the Gullstrand eye model and four optical surfaces of the personalised eye model can be determined with an error of less than 0.25 mm.

  14. [Synthesis and Spectroscopic Study of a Chemosensor for Naked Eye Recognition of Cu2+ and Hg2+].

    PubMed

    Cao, Li; Qian, Ya-ao; Huang, Yan; Cao, Juan; Jia, Chun-man; Liu, Chun-ling; Zhang, Qi; Lu, Zheng-rong

    2015-07-01

    Compound L, as the procedural sensor for the detection of Cu2+ and Hg2+, was designed and synthesized based on the coumarin-modified rhodamine derivative. The structure of compound L was characterized by NMR, high resolution mass spectrometry and infrared method. Its sensing behavior toward various metal ions was investigated with absorbance methods. The study found that L had good selectivity and sensitivity for Cu2+. When addition of various metal ions (Zn2+, Hg2+, Cu2+, Fe3+, Cd2+, CO2+, Ni2+, Mg2+, Ca2+, Al3+, La3+, K+, Na+, Mn2+, Pb2+ and Ag+), only Cu2+ could induce a visible change of solution from colourless to pink and a new absorption band centered at 534 nm appear, which indicated that compound L could be used for the naked eye detection of Cu2+. From UV titration, the detection limit was about 1.9 X 10(-8) mol x L(-1). Test strips based on L were fabricated, and this test strips could act as a convenient and efficient Cu2+ test kit. The binding ratio of the complex of L-Cu2+ was 1:1 according to the Job's plot and high resolution mass spectrometer (HRMS) experiments. Moreover, Upon addition of 1 equiv. EDTA to the mixture of L and Cu2+ in DMSO solution, colour changed from pink to almost colourless, indicating that the EDTA replaced the receptor L to coordinate with Cu2+. Therefore, L could be classified as a reversible sensor for Cu2+. In addition, when adding Hg2+ to L-Cu2+ complexes, a visible change of solution from pink to colourless was observed, while other metal ions didn't cause this change. Thus, L-Cu2+ complex also could be used for the naked eye recognition of Hg2+, and the detection limit was calculated about 2.9 x 10(-1) mol x L(-1) according to the UV titration. Consequently, this procedural sensor L could be use for the orderly naked eye recognition of Cu2+ and Hg2+.

  15. Novel salicylic acid-oriented thiourea-type receptors as colorimetric chemosensor: Synthesis, characterizations and selective naked-eye recognition properties

    NASA Astrophysics Data System (ADS)

    Li, Shaowei; Cao, Xiufang; Chen, Changshui; Ke, Shaoyong

    2012-10-01

    Based on the salicylic acid backbone, three highly sensitive and selective colorimetric chemosensors with an acylthiourea binding unit have been designed, synthesized and characterized. These chemosensors have been utilized for selective recognition of fluoride anions in dry DMSO solution by typical spectroscopic titration techniques. Furthermore, the obtained chemosensors AR1-3 have shown naked-eye sensitivity for detection of biologically important fluoride ion over other anions in solution.

  16. Global optical lightning flash rates determined with the Forte satellite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Light, T.; Davis, S. M.; Boeck, W. L.

    2003-01-01

    Using FORTE photodiode detector (PDD) observations of lightning, we have determined the geographic distribution of nighttime flash rate density. We estimate the PDD flash detection efficiency to be 62% for total lightning through comparison to lightning observations by the TRMM satellite's Lightning Imaging Sensor (LIS), using cases in which FORTE and TRMM viewed the same storm. We present here both seasonal and l,ot,al flash rate maps. We examine some characteristics of the optical emissions of lightning in both high and low flash rate environments, and find that while lightning occurs less frequently over ocean, oceanic lightning flashes are somewhat moremore » powerful, on average, than those over land.« less

  17. Back to Basics: Naked-Eye Astronomical Observation

    ERIC Educational Resources Information Center

    Barclay, Charles

    2003-01-01

    For pupils of both sexes and all ages from about six upwards, the subject of Astronomy holds many fascinations--the rapid changes in knowledge, the large resource of available IT packages and above all the beautiful pictures from Hubble and the large Earth-based telescopes. This article, however, stresses the excitement and importance of naked-eye…

  18. Micro-optical artificial compound eyes.

    PubMed

    Duparré, J W; Wippermann, F C

    2006-03-01

    Natural compound eyes combine small eye volumes with a large field of view at the cost of comparatively low spatial resolution. For small invertebrates such as flies or moths, compound eyes are the perfectly adapted solution to obtaining sufficient visual information about their environment without overloading their brains with the necessary image processing. However, to date little effort has been made to adopt this principle in optics. Classical imaging always had its archetype in natural single aperture eyes which, for example, human vision is based on. But a high-resolution image is not always required. Often the focus is on very compact, robust and cheap vision systems. The main question is consequently: what is the better approach for extremely miniaturized imaging systems-just scaling of classical lens designs or being inspired by alternative imaging principles evolved by nature in the case of small insects? In this paper, it is shown that such optical systems can be achieved using state-of-the-art micro-optics technology. This enables the generation of highly precise and uniform microlens arrays and their accurate alignment to the subsequent optics-, spacing- and optoelectronics structures. The results are thin, simple and monolithic imaging devices with a high accuracy of photolithography. Two different artificial compound eye concepts for compact vision systems have been investigated in detail: the artificial apposition compound eye and the cluster eye. Novel optical design methods and characterization tools were developed to allow the layout and experimental testing of the planar micro-optical imaging systems, which were fabricated for the first time by micro-optics technology. The artificial apposition compound eye can be considered as a simple imaging optical sensor while the cluster eye is capable of becoming a valid alternative to classical bulk objectives but is much more complex than the first system.

  19. Detection of CIN by naked eye visualization after application of acetic acid.

    PubMed

    Londhe, M; George, S S; Seshadri, L

    1997-06-01

    A prospective study was undertaken to determine the sensitivity and specificity of acetic application to the cervix followed by naked eye visualization as a screening test for detection of cervical intraepithelial neoplasia. Three hundred and seventy two sexually active woman in the reproductive age group were studied. All the women underwent Papanicolaou test, acetic acid test and colposcopy. One hundred and seventy five woman were acetic acid test negative, 197 women were acetic acid test positive. The sensitivity of acetic acid test was 72.4%, specificity 54% and false negative rate 15.2%, as compared to papanicolaou test which had a sensitivity of 13.2%, specificity of 96.3% and false negative rate of 24.4%. The advantage of the acetic acid test lies in its easy technique, low cost and high sensitivity which are important factors for determining the efficacy of any screening programme in developing countries.

  20. CONSTRAINTS ON THE EMISSION MODEL OF THE 'NAKED-EYE BURST' GRB 080319B

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdo, A. A.; Abeysekara, A. U.; Linnemann, J. T.

    On 2008 March 19, one of the brightest gamma-ray bursts (GRBs) ever recorded was detected by several ground- and space-based instruments spanning the electromagnetic spectrum from radio to gamma rays. With a peak visual magnitude of 5.3, GRB 080319B was dubbed the 'naked-eye' GRB, as an observer under dark skies could have seen the burst without the aid of an instrument. Presented here are results from observations of the prompt phase of GRB 080319B taken with the Milagro TeV observatory. The burst was observed at an elevation angle of 47 Degree-Sign . Analysis of the data is performed using bothmore » the standard air shower method and the scaler or single-particle technique, which results in a sensitive energy range that extends from {approx}5 GeV to >20 TeV. These observations provide the only direct constraints on the properties of the high-energy gamma-ray emission from GRB 080319B at these energies. No evidence for emission is found in the Milagro data, and upper limits on the gamma-ray flux above 10 GeV are derived. The limits on emission between {approx}25 and 200 GeV are incompatible with the synchrotron self-Compton model of gamma-ray production and disfavor a corresponding range (2 eV-16 eV) of assumed synchrotron peak energies. This indicates that the optical photons and soft ({approx}650 keV) gamma rays may not be produced by the same electron population.« less

  1. "Naked-eye" colorimetric and "turn-on" fluorometric chemosensors for reversible Hg2+ detection.

    PubMed

    Wanichacheva, Nantanit; Praikaew, Panida; Suwanich, Thanapat; Sukrat, Kanjarat

    2014-01-24

    Two new Hg(2+)-colorimetric and fluorescent sensors based on 2-[3-(2-aminoethylsulfanyl) propylsulfanyl]ethanamine covalently bound to one and two units of rhodamine-6G moieties, 1 and 2, were synthesised, and their sensing behaviors toward metal ions were investigated by UV/Vis and fluorescence spectroscopy. Upon the addition of Hg(2+), the sensors exhibited highly sensitive "turn-on" fluorescence enhancement as well as a color change from colorless to pink, which was readily noticeable for naked eye detection. Especially, 1 exhibited the reversible behavior and revealed a very high selectivity in the presence of competitive ions, particularly Cu(2+), Ag(+), Pb(2+), Ca(2+), Cd(2+), Co(2+), Fe(2+), Mn(2+), Na(+), Ni(2+), K(+), Ba(2+), Li(+) and Zn(2+), with a low detection limit of 1.7 ppb toward Hg(2+). Copyright © 2013 Elsevier B.V. All rights reserved.

  2. [Modernized study on eye's signs of blood-stasis syndrome].

    PubMed

    Wu, Rui; Xie, Jian-xiang; Zhao, Feng-da

    2011-03-01

    To make out a computerized formula to diagnose eye's signs of blood-stasis syndrome (BSS), and to improve the previous diagnostic methods by naked eyes. The formula was created by detecting and analyzing the changes of eye's signs in 544 patients (261 of non-BSS and 283 of BSS) quantitatively, adopting computer's color scale principle. And the sensitivity, specificity and accuracy of the formula were verified in 382 patients (97 non-BSS and 285 of BSS). The computerized integral was compared with the naked eye integral, and the normal reference value was calculated with percentile. Various observatory indices of eye's sign were positively correlated with BSS. The specificity of the computerized method was 83.5%, and the diagnostic sensitivity was 89.8%, the accuracy 88.2%, and the correct index 0.733. Comparisons between the computerized integral method and the naked eye integral method showed significant difference in patients of non-BSS or of BSS in various degrees (including mild, moderate and severe) (P < 0.01). The reference value of the naked eye method was below 15. The computerized formula of eye's signs has higher specificity and sensitivity in the diagnosis of BSS, while the naked eye integral method is proved to be useful.

  3. Broadband observations of the naked-eye gamma-ray burst GRB 080319B.

    PubMed

    Racusin, J L; Karpov, S V; Sokolowski, M; Granot, J; Wu, X F; Pal'shin, V; Covino, S; van der Horst, A J; Oates, S R; Schady, P; Smith, R J; Cummings, J; Starling, R L C; Piotrowski, L W; Zhang, B; Evans, P A; Holland, S T; Malek, K; Page, M T; Vetere, L; Margutti, R; Guidorzi, C; Kamble, A P; Curran, P A; Beardmore, A; Kouveliotou, C; Mankiewicz, L; Melandri, A; O'Brien, P T; Page, K L; Piran, T; Tanvir, N R; Wrochna, G; Aptekar, R L; Barthelmy, S; Bartolini, C; Beskin, G M; Bondar, S; Bremer, M; Campana, S; Castro-Tirado, A; Cucchiara, A; Cwiok, M; D'Avanzo, P; D'Elia, V; Valle, M Della; de Ugarte Postigo, A; Dominik, W; Falcone, A; Fiore, F; Fox, D B; Frederiks, D D; Fruchter, A S; Fugazza, D; Garrett, M A; Gehrels, N; Golenetskii, S; Gomboc, A; Gorosabel, J; Greco, G; Guarnieri, A; Immler, S; Jelinek, M; Kasprowicz, G; La Parola, V; Levan, A J; Mangano, V; Mazets, E P; Molinari, E; Moretti, A; Nawrocki, K; Oleynik, P P; Osborne, J P; Pagani, C; Pandey, S B; Paragi, Z; Perri, M; Piccioni, A; Ramirez-Ruiz, E; Roming, P W A; Steele, I A; Strom, R G; Testa, V; Tosti, G; Ulanov, M V; Wiersema, K; Wijers, R A M J; Winters, J M; Zarnecki, A F; Zerbi, F; Mészáros, P; Chincarini, G; Burrows, D N

    2008-09-11

    Long-duration gamma-ray bursts (GRBs) release copious amounts of energy across the entire electromagnetic spectrum, and so provide a window into the process of black hole formation from the collapse of massive stars. Previous early optical observations of even the most exceptional GRBs (990123 and 030329) lacked both the temporal resolution to probe the optical flash in detail and the accuracy needed to trace the transition from the prompt emission within the outflow to external shocks caused by interaction with the progenitor environment. Here we report observations of the extraordinarily bright prompt optical and gamma-ray emission of GRB 080319B that provide diagnostics within seconds of its formation, followed by broadband observations of the afterglow decay that continued for weeks. We show that the prompt emission stems from a single physical region, implying an extremely relativistic outflow that propagates within the narrow inner core of a two-component jet.

  4. Naked eye and spectrophotometric detection of chromogenic insecticide in aquaculture using amine functionalized gold nanoparticles in the presence of major interferents

    NASA Astrophysics Data System (ADS)

    Loganathan, C.; John, S. Abraham

    2017-02-01

    Detection of a chromogenic insecticide, malachite green (MG) using 3,5-diamino-1,2,4-triazole capped gold nanoparticles (DAT-AuNPs) by both naked eye and spectrophotometry was described in this paper. The DAT-AuNPs were prepared by wet chemical method and show absorption maximum at 518 nm. The zeta potential of DAT-AuNPs was found to be - 39.9 mV, suggesting that one of the amine groups of DAT adsorbed on the surface of AuNPs and the other amine group stabilizes the AuNPs from aggregation. The wine red color DAT-AuNPs changes to violet while adding 25 μM MG whereas the absorption band at 518 nm was increased and shifted towards longer wavelength. However, addition of 70 μM MG leads to the aggregation of DAT-AuNPs. This is due to strong electrostatic interaction between ammonium ion of MG and the free amine group of DAT. Based on the color change and shift in SPR band, 25 and 5 μM MG can be easily detected by naked eye and spectrophotometry. The DAT-AuNPs show high selectivity towards MG even in the presence of 5000-fold higher concentrations of common interferents. The practical application was successfully demonstrated by determining MG in fish farm water.

  5. Gravitational lensing by rotating naked singularities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gyulchev, Galin N.; Yazadjiev, Stoytcho S.; Institut fuer Theoretische Physik, Universitaet Goettingen, Friedrich-Hund-Platz 1, D-37077 Goettingen

    We model massive compact objects in galactic nuclei as stationary, axially symmetric naked singularities in the Einstein-massless scalar field theory and study the resulting gravitational lensing. In the weak deflection limit we study analytically the position of the two weak field images, the corresponding signed and absolute magnifications as well as the centroid up to post-Newtonian order. We show that there are static post-Newtonian corrections to the signed magnification and their sum as well as to the critical curves, which are functions of the scalar charge. The shift of the critical curves as a function of the lens angular momentummore » is found, and it is shown that they decrease slightly for the weakly naked and vastly for the strongly naked singularities with the increase of the scalar charge. The pointlike caustics drift away from the optical axis and do not depend on the scalar charge. In the strong deflection limit approximation, we compute numerically the position of the relativistic images and their separability for weakly naked singularities. All of the lensing quantities are compared to particular cases as Schwarzschild and Kerr black holes as well as Janis-Newman-Winicour naked singularities.« less

  6. The Origin of the Optical Flashes: The Case Study of GRB 080319B and GRB 130427A

    NASA Astrophysics Data System (ADS)

    Fraija, N.; Veres, P.

    2018-05-01

    Correlations between optical flashes and gamma-ray emissions in gamma-ray bursts (GRBs) have been searched in order to clarify the question of whether these emissions occur at internal and/or external shocks. Among the most powerful GRBs ever recorded are GRB 080319B and GRB 130427A, which at early phases presented bright optical flashes possibly correlated with γ-ray components. Additionally, both bursts were fortuitously located within the field of view of the TeV γ-ray Milagro and HAWC observatories, and although no statistically significant excess of counts were collected, upper limits were placed on the GeV–TeV emission. Considering the synchrotron self-Compton emission from internal shocks and requiring the GeV–TeV upper limits, we found that the optical flashes and the γ-ray components are produced by different electron populations. Analyzing the optical flashes together with the multiwavelength afterglow observation, we found that these flashes can be interpreted in the framework of the synchrotron reverse shock model when outflows have arbitrary magnetizations.

  7. Adaptive Optics for the Human Eye

    NASA Astrophysics Data System (ADS)

    Williams, D. R.

    2000-05-01

    Adaptive optics can extend not only the resolution of ground-based telescopes, but also the human eye. Both static and dynamic aberrations in the cornea and lens of the normal eye limit its optical quality. Though it is possible to correct defocus and astigmatism with spectacle lenses, higher order aberrations remain. These aberrations blur vision and prevent us from seeing at the fundamental limits set by the retina and brain. They also limit the resolution of cameras to image the living retina, cameras that are a critical for the diagnosis and treatment of retinal disease. I will describe an adaptive optics system that measures the wave aberration of the eye in real time and compensates for it with a deformable mirror, endowing the human eye with unprecedented optical quality. This instrument provides fresh insight into the ultimate limits on human visual acuity, reveals for the first time images of the retinal cone mosaic responsible for color vision, and points the way to contact lenses and laser surgical methods that could enhance vision beyond what is currently possible today. Supported by the NSF Science and Technology Center for Adaptive Optics, the National Eye Institute, and Bausch and Lomb, Inc.

  8. Flashes and Floaters.

    PubMed

    Sharma, Priya; Sridhar, Jayanth; Mehta, Sonia

    2015-09-01

    Flashes and floaters are common ocular complaints. Flashes refer to aberrations of light that are seen in a patient's field of gaze. The flashes can be of varying sizes, colors, frequency, and durations, depending on the cause. Floaters are another common visual phenomenon caused by particles or debris in the vitreous gel of the eye that cause shadows and thus visual changes, especially against bright backgrounds and in brightly lit environments. Flashes and floaters can occur individually or together. This article discusses common causes of flashes and floaters to help with the triaging and management of these patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. A newly synthesized thiazole derivative as a fluoride ion chemosensor: naked-eye, spectroscopic, electrochemical and NMR studies.

    PubMed

    Sarıgüney, Ahmet Burak; Saf, Ahmet Özgür; Coşkun, Ahmet

    2014-07-15

    2,3-Indoledione 3-thiosemicarbazone (TSCI) and a novel compound 3-(2-(4-(4-phenoxyphenyl)thiazol-2-yl)hydrazono)indolin-2-one (FTHI) were synthesized with high yield and characterized by spectroscopic techniques. The complexation behaviors of TSCI and FTHI for various anionic species (F(-), Cl(-), Br(-), I(-), NO2(-), NO3(-), BzO(-), HSO4(-), ClO4(-)) in CH3CN were investigated and compared by UV-vis spectroscopy, cyclic voltammetry and (1)H NMR titration techniques. FTHI showed high degree of selectivity for fluoride over other anions. This selectivity could be easily observed by the naked eye, indicating that FTHI is potential colorimetric sensor for fluoride anion. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Daylight Observations of Venus with Naked Eye in the Goryeosa

    NASA Astrophysics Data System (ADS)

    Lee, Ki-Won

    2017-03-01

    In this paper, we investigate the observations of Venus in daytime that are recorded in the Goryeosa (History of the Goryeo Dynasty, A.D. 918-1392). There are a total of 167 accounts of such observations in this historical book, spanning a period of 378 yr (from 1014 to 1392). These include six accounts where the days of the observation are not specified and two accounts where the phase angles are outside the calculation range of the equation used in our study. We analyze the number distribution of 164 accounts in 16 yr intervals covering the period from 1023 to 1391. We find that this distribution shows its minimum at around 1232, when the Goryeo dynasty moved the capital to the Ganghwa Island because of the Mongol invasion, and its maximum at around 1390, about the time when the dynasty fell. In addition, we calculate the azimuth, altitude, solar elongation, and apparent magnitude of Venus at sunset for 159 observations, excluding the eight accounts mentioned above, using the DE 406 ephemeris and modern astronomical algorithms. We find that the average elongation and magnitude of Venus on the days of those accounts were and -4.5, respectively, whereas the minimum magnitude was -3.8. The results of this study are useful for estimating the practical conditions for observing Venus in daylight with the naked eye and they also provide additional insight into the corresponding historical accounts contained in the Goryeosa.

  11. Development of a Textile Nanocomposite as Naked Eye Indicator of the Exposition to Strong Acids

    PubMed Central

    Pallás, Isabel; Marcos, Maria D.

    2017-01-01

    Chemical burns, mainly produced by acids, are a topic of concern. A new sensing material for the detection of strong acids able to be incorporated into textiles has been developed. The material is prepared by the covalent attachment of 2,2′,4,4′,4″-pentamethoxy triphenyl methanol to a mesoporous material which further is included in a nitro resin to obtain a colourless composite. The response of this composite to diverse acid solutions was tested showing the appearance of an intense purple colour (with a colour difference higher than 160) that can be monitored by the naked eye or could be easily digitised to feed an instrumental sensor. Reversibility and resistance to washing cycles were studied with positive results. Finally, the response of the sensing composite to acid vapours was assayed, observing a colour change similar to that found in solution. PMID:28926950

  12. Optical quality of the living cat eye

    PubMed Central

    Bonds, A. B.

    1974-01-01

    1. The optical quality of the living cat eye was measured under conditions similar to those of cat retinal ganglion cell experiments by recording the aerial image of a nearly monochromatic thin line of light. 2. Experiments were performed to assess the nature of the fundal reflexion of the cat eye, which was found to behave essentially as a diffuser. 3. The optical Modulation Transfer Function (MTF) was calculated from the measured aerial linespread using Fourier mathematics; the MTF of a `typical' cat eye was averaged from data collected from ten eyes. 4. The state of focus of the optical system, the pupil size and the angle of the light incident on the eye were all varied to determine their effect on image quality. 5. By using an image rotator, the aerial linespread was measured for several orientations of the line; these measurements yielded an approximation of the two-dimensional pointspread completely characterizing the optical system. 6. Evidence is reviewed to show that the optical resolution of the cat, albeit some 3-5 times worse than that of human, appears to be better than the neural resolution of its retina and its visual system as a whole. PMID:4449081

  13. Optical quality of the living cat eye.

    PubMed

    Bonds, A B

    1974-12-01

    1. The optical quality of the living cat eye was measured under conditions similar to those of cat retinal ganglion cell experiments by recording the aerial image of a nearly monochromatic thin line of light.2. Experiments were performed to assess the nature of the fundal reflexion of the cat eye, which was found to behave essentially as a diffuser.3. The optical Modulation Transfer Function (MTF) was calculated from the measured aerial linespread using Fourier mathematics; the MTF of a ;typical' cat eye was averaged from data collected from ten eyes.4. The state of focus of the optical system, the pupil size and the angle of the light incident on the eye were all varied to determine their effect on image quality.5. By using an image rotator, the aerial linespread was measured for several orientations of the line; these measurements yielded an approximation of the two-dimensional pointspread completely characterizing the optical system.6. Evidence is reviewed to show that the optical resolution of the cat, albeit some 3-5 times worse than that of human, appears to be better than the neural resolution of its retina and its visual system as a whole.

  14. Visual recovery from optic atrophy following acute optic neuropathy in the fellow eye.

    PubMed

    Ornek, Kemal; Ornek, Nurgül

    2012-06-01

    The left eye of a 65-year-old male was blind due to optic atrophy and only seeing eye had also dry type age-related macular degeneration. An anterior ischemic optic neuropathy developed in the better seeing eye. Vision recovered in the blind eye in a short time after losing the better eye. Gaining some vision in a blind eye may be an adaptation of visual pathway in such patients.

  15. An efficient probe for rapid detection of cyanide in water at parts per billion levels and naked-eye detection of endogenous cyanide.

    PubMed

    Kumari, Namita; Jha, Satadru; Bhattacharya, Santanu

    2014-03-01

    A new molecular probe based on an oxidized bis-indolyl skeleton has been developed for rapid and sensitive visual detection of cyanide ions in water and also for the detection of endogenously bound cyanide. The probe allows the "naked-eye" detection of cyanide ions in water with a visual color change from red to yellow (Δλmax =80 nm) with the immediate addition of the probe. It shows high selectivity towards the cyanide ion without any interference from other anions. The detection of cyanide by the probe is ratiometric, thus making the detection quantitative. A Michael-type addition reaction of the probe with the cyanide ion takes place during this chemodosimetric process. In water, the detection limit was found to be at the parts per million level, which improved drastically when a neutral micellar medium was employed, and it showed a parts-per-billion-level detection, which is even 25-fold lower than the permitted limits of cyanide in water. The probe could also efficiently detect the endogenously bound cyanide in cassava (a staple food) with a clear visual color change without requiring any sample pretreatment and/or any special reaction conditions such as pH or temperature. Thus the probe could serve as a practical naked-eye probe for "in-field" experiments without requiring any sophisticated instruments. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. A novel pyridyl triphenylamine-BODIPY aldoxime: Naked-eye visible and fluorometric chemodosimeter for hypochlorite

    NASA Astrophysics Data System (ADS)

    Xu, Xiu-xiu; Qian, Ying

    2017-08-01

    An aldoxime containing fluorescent probe based on vinylpydine-appended triphenylamine-BODIPY has been designed and used for hypochlorite detection. OX-PPA-BODIPY was developed by introducing an aldoxime group into the 2-position of BODIPY, which can be used for the detection of hypochlorite with a sharp color change from pink to green. The attachment of 4-vinylpyridine moiety to triphenylamine-BODIPY constructs a fluorogen with desirable conjugated system. The probe, which displays extremely weak fluorescence owing to the Cdbnd N isomerization mechanism at 2-position of BODIPY, responds to HClO/ClO- through a dramatic enhancement of its fluorescence intensity. This new probe, a naked-eye visible and fluorometric chemodosimeter, exhibits high selectivity and sensitivity toward hypochlorite over other reactive oxygen species (ROS) and anions. The detection is accompanied by a 20-fold increase in fluorescent intensity (ΦF from 0.02 to 0.43). The detection limit of the probe for hypochlorite is 7.37 × 10- 7 M. Moreover, OX-PPA-BODIPY can be used to detect hypochlorite in real water samples.

  17. OTD Observations of Continental US Ground and Cloud Flashes

    NASA Technical Reports Server (NTRS)

    Koshak, William

    2007-01-01

    Lightning optical flash parameters (e.g., radiance, area, duration, number of optical groups, and number of optical events) derived from almost five years of Optical Transient Detector (OTD) data are analyzed. Hundreds of thousands of OTD flashes occurring over the continental US are categorized according to flash type (ground or cloud flash) using US National Lightning Detection Network TM (NLDN) data. The statistics of the optical characteristics of the ground and cloud flashes are inter-compared on an overall basis, and as a function of ground flash polarity. A standard two-distribution hypothesis test is used to inter-compare the population means of a given lightning parameter for the two flash types. Given the differences in the statistics of the optical characteristics, it is suggested that statistical analyses (e.g., Bayesian Inference) of the space-based optical measurements might make it possible to successfully discriminate ground and cloud flashes a reasonable percentage of the time.

  18. Optical properties of the mouse eye

    PubMed Central

    Geng, Ying; Schery, Lee Anne; Sharma, Robin; Dubra, Alfredo; Ahmad, Kamran; Libby, Richard T.; Williams, David R.

    2011-01-01

    The Shack-Hartmann wavefront sensor (SHWS) spots upon which ocular aberration measurements depend have poor quality in mice due to light reflected from multiple retinal layers. We have designed and implemented a SHWS that can favor light from a specific retinal layer and measured monochromatic aberrations in 20 eyes from 10 anesthetized C57BL/6J mice. Using this instrument, we show that mice are myopic, not hyperopic as is frequently reported. We have also measured longitudinal chromatic aberration (LCA) of the mouse eye and found that it follows predictions of the water-filled schematic mouse eye. Results indicate that the optical quality of the mouse eye assessed by measurement of its aberrations is remarkably good, better for retinal imaging than the human eye. The dilated mouse eye has a much larger numerical aperture (NA) than that of the dilated human eye (0.5 NA vs. 0.2 NA), but it has a similar amount of root mean square (RMS) higher order aberrations compared to the dilated human eye. These measurements predict that adaptive optics based on this method of wavefront sensing will provide improvements in retinal image quality and potentially two times higher lateral resolution than that in the human eye. PMID:21483598

  19. Optical eye simulator for laser dazzle events.

    PubMed

    Coelho, João M P; Freitas, José; Williamson, Craig A

    2016-03-20

    An optical simulator of the human eye and its application to laser dazzle events are presented. The simulator combines optical design software (ZEMAX) with a scientific programming language (MATLAB) and allows the user to implement and analyze a dazzle scenario using practical, real-world parameters. Contrary to conventional analytical glare analysis, this work uses ray tracing and the scattering model and parameters for each optical element of the eye. The theoretical background of each such element is presented in relation to the model. The overall simulator's calibration, validation, and performance analysis are achieved by comparison with a simpler model based uponCIE disability glare data. Results demonstrate that this kind of advanced optical eye simulation can be used to represent laser dazzle and has the potential to extend the range of applicability of analytical models.

  20. Data processing from lobster eye type optics

    NASA Astrophysics Data System (ADS)

    Nentvich, Ondrej; Stehlikova, Veronika; Urban, Martin; Hudec, Rene; Sieger, Ladislav

    2017-05-01

    Wolter I optics are commonly used for imaging in X-Ray spectrum. This system uses two reflections, and at higher energies, this system is not so much efficient but has a very good optical resolution. Here is another type of optics Lobster Eye, which is using also two reflections for focusing rays in Schmidt's or Angel's arrangement. Here is also possible to use Lobster eye optics as two one dimensional independent optics. This paper describes advantages of one dimensional and two dimensional Lobster Eye optics in Schmidt's arrangement and its data processing - find out a number of sources in wide field of view. Two dimensional (2D) optics are suitable to detect the number of point X-ray sources and their magnitude, but it is necessary to expose for a long time because a 2D system has much lower transitivity, due to double reflection, compared to one dimensional (1D) optics. Not only for this reason, two 1D optics are better to use for lower magnitudes of sources. In this case, additional image processing is necessary to achieve a 2D image. This article describes of approach an image reconstruction and advantages of two 1D optics without significant losses of transitivity.

  1. Optics of human eye: 400 years of exploration from Galileo's time.

    PubMed

    Artal, Pablo; Tabernero, Juan

    2010-06-01

    We present a brief historical background and a description of the main features of the eye's optical properties: the eye is a simple, but rather optimized, optical instrument. It is only since Galileo's time that the importance of the eye as a part of different optical instruments has driven a continuous scientific exploration of ocular optics. In the past decade, the use of wavefront sensing technology allowed us to complete our understating of eye optics as a robust aplanatic system.

  2. Synthesis and characterization of azo-guanidine based alcoholic media naked eye DNA sensor

    PubMed Central

    Hashmat, Uzma; Yousaf, Muhammad; Lal, Bhajan; Ullah, Shafiq; Holder, Alvin A.; Badshah, Amin

    2016-01-01

    DNA sensing always has an open meadow of curiosity for biotechnologists and other researchers. Recently, in this field, we have introduced an emerging class of molecules containing azo and guanidine functionalities. In this study, we have synthesized three new compounds (UA1, UA6 and UA7) for potential application in DNA sensing in alcoholic medium. The synthesized materials were characterized by elemental analysis, FTIR, UV-visible, 1H NMR and 13C NMR spectroscopies. Their DNA sensing potential were investigated by UV-visible spectroscopy. The insight of interaction with DNA was further investigated by electrochemical (cyclic voltammetry) and hydrodynamic (viscosity) studies. The results showed that compounds have moderate DNA binding properties, with the binding constants range being 7.2 × 103, 2.4 × 103 and 0.2 × 103 M−1, for UA1, UA6 and UA7, respectively. Upon binding with DNA, there was a change in colour (a blue shift in the λmax value) which was observable with a naked eye. These results indicated the potential of synthesized compounds as DNA sensors with detection limit 1.8, 5.8 and 4.0 ng µl−1 for UA1, UA6 and UA7, respectively. PMID:28018613

  3. Flash protection controller

    DOEpatents

    Galbraith, L.K.

    1979-12-07

    A controller provides a high voltage to maintain an electro-optic shutter in a transparent condition until a flash of light which would be harmful to personnel is sensed by a phototransistor. The controller then shorts the shutter to ground to minimize light transmission to the user and maintains light transmission at the pre-flash level for a predetermined time to allow the flash to subside. A log converter and differential trigger circuit keep the controller from being triggered by other light flashes which are not dangerous.

  4. Flash protection controller

    DOEpatents

    Galbraith, Lee K.

    1981-01-01

    A controller provides a high voltage to maintain an electro-optic shutter in a transparent condition until a flash of light which would be harmful to personnel is sensed by a phototransistor. The controller then shorts the shutter to ground to minimize light transmission to the user and maintains light transmission at the pre-flash level for a predetermined time to allow the flash to subside. A log converter and differential trigger circuit keep the controller from being triggered by other light flashes which are not dangerous.

  5. Correcting highly aberrated eyes using large-stroke adaptive optics.

    PubMed

    Sabesan, Ramkumar; Ahmad, Kamran; Yoon, Geunyoung

    2007-11-01

    To investigate the optical performance of a large-stroke deformable mirror in correcting large aberrations in highly aberrated eyes. A large-stroke deformable mirror (Mirao 52D; Imagine Eyes) and a Shack-Hartmann wavefront sensor were used in an adaptive optics system. Closed-loop correction of the static aberrations of a phase plate designed for an advanced keratoconic eye was performed for a 6-mm pupil. The same adaptive optics system was also used to correct the aberrations in one eye each of two moderate keratoconic and three normal human eyes for a 6-mm pupil. With closed-loop correction of the phase plate, the total root-mean-square (RMS) over a 6-mm pupil was reduced from 3.54 to 0.04 microm in 30 to 40 iterations, corresponding to 3 to 4 seconds. Adaptive optics closed-loop correction reduced an average total RMS of 1.73+/-0.998 to 0.10+/-0.017 microm (higher order RMS of 0.39+/-0.124 to 0.06+/-0.004 microm) in the three normal eyes and 2.73+/-1.754 to 0.10+/-0.001 microm (higher order RMS of 1.82+/-1.058 to 0.05+/-0.017 microm) in the two keratoconic eyes. Aberrations in both normal and highly aberrated eyes were successfully corrected using the large-stroke deformable mirror to provide almost perfect optical quality. This mirror can be a powerful tool to assess the limit of visual performance achievable after correcting the aberrations, especially in eyes with abnormal corneal profiles.

  6. A novel pyridyl triphenylamine-BODIPY aldoxime: Naked-eye visible and fluorometric chemodosimeter for hypochlorite.

    PubMed

    Xu, Xiu-Xiu; Qian, Ying

    2017-08-05

    An aldoxime containing fluorescent probe based on vinylpydine-appended triphenylamine-BODIPY has been designed and used for hypochlorite detection. OX-PPA-BODIPY was developed by introducing an aldoxime group into the 2-position of BODIPY, which can be used for the detection of hypochlorite with a sharp color change from pink to green. The attachment of 4-vinylpyridine moiety to triphenylamine-BODIPY constructs a fluorogen with desirable conjugated system. The probe, which displays extremely weak fluorescence owing to the CN isomerization mechanism at 2-position of BODIPY, responds to HClO/ClO - through a dramatic enhancement of its fluorescence intensity. This new probe, a naked-eye visible and fluorometric chemodosimeter, exhibits high selectivity and sensitivity toward hypochlorite over other reactive oxygen species (ROS) and anions. The detection is accompanied by a 20-fold increase in fluorescent intensity (Φ F from 0.02 to 0.43). The detection limit of the probe for hypochlorite is 7.37×10 -7 M. Moreover, OX-PPA-BODIPY can be used to detect hypochlorite in real water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Eye vision system using programmable micro-optics and micro-electronics

    NASA Astrophysics Data System (ADS)

    Riza, Nabeel A.; Amin, M. Junaid; Riza, Mehdi N.

    2014-02-01

    Proposed is a novel eye vision system that combines the use of advanced micro-optic and microelectronic technologies that includes programmable micro-optic devices, pico-projectors, Radio Frequency (RF) and optical wireless communication and control links, energy harvesting and storage devices and remote wireless energy transfer capabilities. This portable light weight system can measure eye refractive powers, optimize light conditions for the eye under test, conduct color-blindness tests, and implement eye strain relief and eye muscle exercises via time sequenced imaging. Described is the basic design of the proposed system and its first stage system experimental results for vision spherical lens refractive error correction.

  8. Laser Measurement of Optical Errors of the Eye

    ERIC Educational Resources Information Center

    Colicchia, Giuseppe; Wiesner, Hartmut

    2006-01-01

    One way to motivate students' interest in physics is to teach it in the context of medicine. Optics, for example, can be taught with examples from the eye. For many years simple optics of lenses has been taught using a model of the eye. However, recent advances in using lasers for ophthalmological (ocular) examinations can be used to increase…

  9. Objective measurement of the optical image quality in the human eye

    NASA Astrophysics Data System (ADS)

    Navarro, Rafael M.

    2001-05-01

    This communication reviews some recent studies on the optical performance of the human eye. Although the retinal image cannot be recorded directly, different objective methods have been developed, which permit to determine optical quality parameters, such as the Point Spread Function (PSF), the Modulation Transfer Function (MTF), the geometrical ray aberrations or the wavefront distortions, in the living human eye. These methods have been applied in both basic and applied research. This includes the measurement of the optical performance of the eye across visual field, the optical quality of eyes with intraocular lens implants, the aberrations induced by LASIK refractive surgery, or the manufacture of customized phase plates to compensate the wavefront aberration in the eye.

  10. Bilateral Glaucomatous Optic Neuropathy Caused by Eye Rubbing.

    PubMed

    Savastano, Alfonso; Savastano, Maria Cristina; Carlomusto, Laura; Savastano, Silvio

    2015-01-01

    In this report, we describe a particular condition of a 52-year-old man who showed advanced bilateral glaucomatous-like optic disc damage, even though the intraocular pressure resulted normal during all examinations performed. Visual field test, steady-state pattern electroretinogram, retinal nerve fiber layer and retinal tomographic evaluations were performed to evaluate the optic disc damage. Over a 4-year observational period, his visual acuity decreased to 12/20 in the right eye and counting fingers in the left eye. Visual fields were severely compromised, and intraocular pressure values were not superior to 14 mm Hg during routine examinations. An accurate anamnesis and the suspicion of this disease represent a crucial aspect to establish the correct diagnosis. In fact, our patient strongly rubbed his eyes for more than 10 h per day. Recurrent and continuous eye rubbing can induce progressive optic neuropathy, causing severe visual field damage similar to the pathology of advanced glaucoma.

  11. Naked eye screening of 11 phenolic compounds and colorimetric determination using polydiacetylene vesicles with α-cyclodextrin

    NASA Astrophysics Data System (ADS)

    Anekthirakun, Pimpimon; Sukwattanasinitt, Mongkol; Tuntulani, Thawatchai; Imyim, Apichat

    2013-07-01

    The colorimetric response (CR) of poly(10,12-pentacosadiynoic acid) vesicles (PPCDA) induced by α-cyclodextrin (α-CD) in an aqueous solution has been studied. Various parameters affecting the CR, such as response time and concentration were investigated. The blue color of 0.01 mM PPCDA solution became pinkish red with the addition of α-CD at the concentration higher than 3 mM. The inhibition of the color transition from blue to red was investigated using 11 phenolic compounds. The color transition could be inhibited and observed by naked eye in the presence of 4 phenolic compounds, i.e. 4-nitrophenol (4-NP) and 4-bromophenol (4-BP) and 4-chlorophenol (4-CP) and 3-nitrophenol (3-NP). A colorimetric method for the determination of these compounds was validated and applied for surface water analysis. The linear range from the plot of CR against phenolic compounds concentration was in the order of 0.5-2.0 mM with R2 more than 0.99. The recoveries were 90-95% with good precision (1-4%RSD, n = 10).

  12. An ancient eye test--using the stars.

    PubMed

    Bohigian, George M

    2008-01-01

    Vision testing in ancient times was as important as it is today. The predominant vision testing in some cultures was the recognition and identification of constellations and celestial bodies of the night sky. A common ancient naked eye test used the double star of the Big Dipper in the constellation Ursa Major or the Big Bear. The second star from the end of the handle of the Big Dipper is an optical double star. The ability to perceive this separation of these two stars, Mizar and Alcor, was considered a test of good vision and was called the "test" or presently the Arab Eye Test. This article is the first report of the correlation of this ancient eye test to the 20/20 line in the current Snellen visual acuity test. This article describes the astronomy, origin, history, and the practicality of this test and how it correlates with the present day Snellen visual acuity test.

  13. Using the human eye to image space radiation or the history and status of the light flash phenomena

    NASA Astrophysics Data System (ADS)

    Fuglesang, C.

    2007-10-01

    About 80% of people who travel in space experience sudden phosphenes, commonly called light flashes (LF). Although the detailed physiological process is still not known, the LFs are caused by particles in the cosmic radiation field. Indeed, by counting LFs one can even make a crude image of the radiation environment around the Earth. Studies on the space station Mir with the SilEye experiment correlated LFs with charged particles traversing the eye. It was found that a nucleus in the radiation environment has roughly a 1% probability of causing a light flash, whereas the proton's probability is almost three orders of magnitude less. As a function of linear energy transfer (LET), the probability increased with ionization above 10 keV/μm, reaching about 5% at 50 keV/μm. The investigations are continuing on the International Space Station (ISS) with the Alteino/SileEye-3 detector, which is also a precursor to the large Anomalous Long Term Effects on Astronauts (ALTEA) facility. These detectors are also measuring—imaging—the radiation environment inside the ISS, which will be compared to Geant4 simulations from the DESIRE project. To further the understanding of the LF phenomena, a survey among current NASA and ESA astronauts was recently conducted. The LFs are predominantly noticed before sleep and some respondents even thought it disturbed their sleep. The LFs appear white, have elongated shapes, and most interestingly, often come with a sense of motion. Comparing the shapes quoted from space observations with ground experiments done by researchers in the 1970s, it seems likely that some 5-10% of the LFs in space are due to Cherenkov light in the eye. However, the majority is most likely caused by some direct interaction in the retina.

  14. An artificial elementary eye with optic flow detection and compositional properties.

    PubMed

    Pericet-Camara, Ramon; Dobrzynski, Michal K; Juston, Raphaël; Viollet, Stéphane; Leitel, Robert; Mallot, Hanspeter A; Floreano, Dario

    2015-08-06

    We describe a 2 mg artificial elementary eye whose structure and functionality is inspired by compound eye ommatidia. Its optical sensitivity and electronic architecture are sufficient to generate the required signals for the measurement of local optic flow vectors in multiple directions. Multiple elementary eyes can be assembled to create a compound vision system of desired shape and curvature spanning large fields of view. The system configurability is validated with the fabrication of a flexible linear array of artificial elementary eyes capable of extracting optic flow over multiple visual directions. © 2015 The Author(s).

  15. Study of multi-channel optical system based on the compound eye

    NASA Astrophysics Data System (ADS)

    Zhao, Yu; Fu, Yuegang; Liu, Zhiying; Dong, Zhengchao

    2014-09-01

    As an important part of machine vision, compound eye optical systems have the characteristics of high resolution and large FOV. By applying the compound eye optical systems to target detection and recognition, the contradiction between large FOV and high resolution in the traditional single aperture optical systems could be solved effectively and also the parallel processing ability of the optical systems could be sufficiently shown. In this paper, the imaging features of the compound eye optical systems are analyzed. After discussing the relationship between the FOV in each subsystem and the contact ratio of the FOV in the whole system, a method to define the FOV of the subsystem is presented. And a compound eye optical system is designed, which is based on the large FOV synthesized of multi-channels. The compound eye optical system consists with a central optical system and array subsystem, in which the array subsystem is used to capture the target. The high resolution image of the target could be achieved by the central optical system. With the advantage of small volume, light weight and rapid response speed, the optical system could detect the objects which are in 3km and FOV of 60°without any scanning device. The objects in the central field 2w=5.1°could be imaged with high resolution so that the objects could be recognized.

  16. Laser Measurement of Optical Errors of the Eye

    NASA Astrophysics Data System (ADS)

    Colicchia, Giuseppe; Wiesner, Hartmut

    2006-11-01

    One way to motivate students' interest in physics is to teach it in the context of medicine. Optics, for example, can be taught with examples from the eye. For many years simple optics of lenses has been taught using a model of the eye.2 However, recent advances in using lasers for ophthalmological (ocular) examinations3 can be used to increase motivation and provide a look at sophisticated use of lasers in ophthalmology. This paper describes a set of experiments that help students learn about contemporary methods of ophthalmological examinations that do not require the traditional approach of placing many lenses in front of the patient's eyes.

  17. MAGNETIC TOPOLOGY OF A NAKED SUNSPOT: IS IT REALLY NAKED?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sainz Dalda, A.; Vargas Dominguez, S.; Tarbell, T. D.

    The high spatial, temporal, and spectral resolution achieved by Hinode instruments gives much better understanding of the behavior of some elusive solar features, such as pores and naked sunspots. Their fast evolution and, in some cases, their small sizes have made their study difficult. The moving magnetic features (MMFs) have been studied during the last 40 years. They have been always associated with sunspots, especially with the penumbra. However, a recent observation of a naked sunspot (one with no penumbra) has shown MMF activity. The authors of this reported observation expressed their reservations about the explanation given to the bipolarmore » MMF activity as an extension of the penumbral filaments into the moat. How can this type of MMF exist when a penumbra does not? In this Letter, we study the full magnetic and (horizontal) velocity topology of the same naked sunspot, showing how the existence of a magnetic field topology similar to that observed in sunspots can explain these MMFs, even when the intensity map of the naked sunspot does not show a penumbra.« less

  18. Tree-based solvers for adaptive mesh refinement code FLASH - I: gravity and optical depths

    NASA Astrophysics Data System (ADS)

    Wünsch, R.; Walch, S.; Dinnbier, F.; Whitworth, A.

    2018-04-01

    We describe an OctTree algorithm for the MPI parallel, adaptive mesh refinement code FLASH, which can be used to calculate the gas self-gravity, and also the angle-averaged local optical depth, for treating ambient diffuse radiation. The algorithm communicates to the different processors only those parts of the tree that are needed to perform the tree-walk locally. The advantage of this approach is a relatively low memory requirement, important in particular for the optical depth calculation, which needs to process information from many different directions. This feature also enables a general tree-based radiation transport algorithm that will be described in a subsequent paper, and delivers excellent scaling up to at least 1500 cores. Boundary conditions for gravity can be either isolated or periodic, and they can be specified in each direction independently, using a newly developed generalization of the Ewald method. The gravity calculation can be accelerated with the adaptive block update technique by partially re-using the solution from the previous time-step. Comparison with the FLASH internal multigrid gravity solver shows that tree-based methods provide a competitive alternative, particularly for problems with isolated or mixed boundary conditions. We evaluate several multipole acceptance criteria (MACs) and identify a relatively simple approximate partial error MAC which provides high accuracy at low computational cost. The optical depth estimates are found to agree very well with those of the RADMC-3D radiation transport code, with the tree-solver being much faster. Our algorithm is available in the standard release of the FLASH code in version 4.0 and later.

  19. A plasmonic ELISA for the naked-eye detection of chromium ions in water samples.

    PubMed

    Yao, Cuize; Yu, Shiting; Li, Xiuqing; Wu, Ze; Liang, Jiajie; Fu, Qiangqiang; Xiao, Wei; Jiang, Tianjiu; Tang, Yong

    2017-02-01

    Here, we describe the development of a triangular silver nanoprism (AgNPR) etching-based plasmonic ELISA for the colorimetric determination of Cr(III) levels in environmental water samples. This involved the creation of a novel signal generation system (substrate reaction solution) for a competitive ELISA in which hydrogen peroxide (H 2 O 2 ) is used to etch triangular AgNPRs, inducing a change in color. This is achieved by controlling the H 2 O 2 concentration that remains after degradation by catalase, which is conjugated to the secondary antibody of the ELISA. Because the degree of color change and the shift in the absorption spectrum of the substrate reaction solution are closely correlated with the Cr(III) concentration, this plasmonic ELISA can be used not only for the quantification of Cr(III) concentrations ranging from 3.13 to 50 ng/mL, with a limit of detection (LOD) of 3.13 ng/mL, but also for the visual detection (indicated by a color change from blue to mauve) of Cr(III) with a sensitivity of 6.25 ng/mL by the naked eye. Therefore, the plasmonic ELISA developed in this work represents a new strategy for heavy metal ion detection and has high potential applicability in resource-constrained areas. Graphical Abstract Schematic diagram of triangular silver nanoprism etching-based signal generation system.

  20. Optical aberrations, retinal image quality and eye growth: Experimentation and modeling

    NASA Astrophysics Data System (ADS)

    Tian, Yibin

    2007-12-01

    Retinal image quality is important for normal eye growth. Optical aberrations are of interest for two reasons: first, they degrade retinal images; second, they might provide some cues to defocus. Higher than normal ocular aberrations have been previously associated with human myopia. However, these studies were cross-sectional in design, and only reported aberrations in terms of root mean square (RMS) errors of Zernike coefficients, a poor metric of optical quality. This dissertation presents results from investigations of ocular optical aberrations, retinal image quality and eye growth in chicks and humans. A number of techniques were utilized, including Shack-Hartmann aberrometry, high-frequency A-scan ultrasonography, ciliary nerve section (CNX), photorefractive keratectomy (PRK) as well as computer simulations and modeling. A technique to extract light scatter information from Shack-Hartmann images was also developed. The main findings of the dissertation are summarized below. In young chicks, most ocular aberrations decreased with growth in both normal and CNX eyes, and there were diurnal fluctuations in some aberrations. Modeling suggested active reduction in higher order aberrations (HOAs) during early development. Although CNX eyes manifested greater than normal HOAs, they showed near normal growth. Retinal image degradation varied greatly among individual eyes post-PRK in young chicks. Including light scatter information into analyses of retinal image quality better estimated the latter. Albino eyes showed more severe retinal image degradation than normal eyes, due to increased optical aberrations and light scatter, but their growth was similar to those of normal eyes, implying that they are relatively insensitive to retina image quality. Although the above results questioned the influence of optical aberrations on early ocular growth, some optical quality metrics, derived from optical aberrations data, could predict how much the eyes of young chicks

  1. Torsion Induced Traumatic Optic Neuropathy (TITON): Animal Model for Diagnostics, Drugs Delivery, and Therapeutics for Injuries to the Cental Nervous System

    DTIC Science & Technology

    2016-06-01

    neck and the eye coils are actively decoupled. The following parameters will be used: slice thickness = 1 mm, TR = 4 s, TE = 13 ms, label duration... Eyes were removed with 3-5 mm of optic nerve intact taking care not to stretch or otherwise injure the nerve. Eyes were flash frozen in liquid...nitrogen, then stored at -80°C. The eyes were then sectioned through the optic nerve using a cryostat, then transferred to indium titanium oxide-coated

  2. Test strips based on iron(iii)-impregnated alginate/polyacrylonitrile nanofibers for naked eye screening of tetracycline.

    PubMed

    Li, Yan; Mohammed, Abedalwafa; Li, De; Wang, Lu

    2018-05-03

    Tetracycline (TC) is an inexpensive broad-spectrum antibiotic used to treat infectious diseases and to promote growth in animals. However, driven by economic interest, abuse of TC poses a serious threat to human beings, and it remains a significant challenge to create easy-to-use TC colorimetric test strips for public use. Herein, we present a strategy to prepare free-standing, nanofibrous structured test strips with tortuous porous structure and large surface area by combining polyacrylonitrile nanofibrous membranes (PAN NMs), alginate, and Fe3+. In this approach, alginate was first functionalized on the PAN NMs and then, Fe3+ was assembled into the alginate to construct a TC-sensing surface. The resultant test strips exhibited the following integrated properties: fast sensing process (10 min), low naked eye detection limit (5 μg kg-1), excellent anti-interference ability, and satisfactory reusability. Furthermore, the TC concentration-dependent color change (yellow to maroon) was quantitatively visualized by an iPhone read-out hue parameter. All the findings indicate that this intriguing approach may pave the way for versatile designing of NMs to serve as a preventive treatment for the public.

  3. A Multifunctional Bimetallic Molecular Device for Ultrasensitive Detection, Naked-Eye Recognition, and Elimination of Cyanide Ions.

    PubMed

    Chow, Cheuk-Fai; Ho, Pui-Yu; Wong, Wing-Leung; Gong, Cheng-Bin

    2015-09-07

    A new bimetallic Fe(II) -Cu(II) complex was synthesized, characterized, and applied as a selective and sensitive sensor for cyanide detection in water. This complex is the first multifunctional device that can simultaneously detect cyanide ions in real water samples, amplify the colorimetric signal upon detection for naked-eye recognition at the parts-per-million (ppb) level, and convert the toxic cyanide ion into the much safer cyanate ion in situ. The mechanism of the bimetallic complex for high-selectivity recognition and signaling toward cyanide ions was investigated through a series of binding kinetics of the complex with different analytes, including CN(-) , SO4 (2-) , HCO3 (-) , HPO4 (2-) , N3 (-) , CH3 COO(-) , NCS(-) , NO3 (-) , and Cl(-) ions. In addition, the use of the indicator/catalyst displacement assay (ICDA) is demonstrated in the present system in which one metal center acts as a receptor and inhibitor and is bridged to another metal center that is responsible for signal transduction and catalysis, thus showing a versatile approach to the design of new multifunctional devices. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Flash!

    NASA Astrophysics Data System (ADS)

    Schilling, Govert

    2002-04-01

    About three times a day our sky flashes with a powerful pulse of gamma ray bursts (GRB), invisible to human eyes but not to astronomers' instruments. The sources of this intense radiation are likely to be emitting, within the span of seconds or minutes, more energy than the sun will in its entire 10 billion years of life. Where these bursts originate, and how they come to have such incredible energies, is a mystery scientists have been trying to solve for three decades. The phenomenon has resisted study -- the flashes come from random directions in space and vanish without trace -- until very recently. In what could be called a cinematic conflation of Flash Gordon and The Hunt for Red October, Govert Schilling's Flash!: The Hunt for the Biggest Explosions in the Universe describes the exciting and ever-changing field of GRB research. Based on interviews with leading scientists, Flash! provides an insider's account of the scientific challenges involved in unravelling the enigmatic nature of GRBs. A science writer who has followed the drama from the very start, Schilling describes the ambition and jealousy, collegiality and competition, triumph and tragedy, that exists among those who have embarked on this recherche. Govert Schilling is a Dutch science writer and astronomy publicist. He is a contributing editor of Sky and Telescope magazine, and regularly writes for the news sections of Science and New Scientist. Schilling is the astronomy writer for de Volkskrant, one of the largest national daily newspapers in The Netherlands, and frequently talks about the Universe on Dutch radio broadcasts. He is the author of more than twenty popular astronomy books, and hundreds of newspaper and magazine articles on astronomy.

  5. Employing a hydrazine linked asymmetric double naphthalene hybrid for efficient naked eye detection of F-: Crystal structure with real application for F-

    NASA Astrophysics Data System (ADS)

    Bhattacharyya, Arghyadeep; Makhal, Subhash Chandra; Ghosh, Soumen; Guchhait, Nikhil

    2018-06-01

    An asymmetric hydrazide, (12E, 13E)-2-((naphthalen-1-yl) methylene)-1-(1-(2-hydroxynaphthalen-6-yl) ethylidene) hydrazine (abbreviated as AH) is synthesized and characterized by standard techniques and crystal structure of AH has been obtained. The naked eye detection of F- in aqueous acetonitrile (acetonitrile: water = 7:3/v:v) by AH has been investigated by UV-Visible titration and in presence of other anions, the limit of detection being 1.31 × 10-6(M). The mechanism of F- sensing has been explored by 1H NMR titration. AH undergoes hydrogen bonding with F- followed by deprotonation. The practical utility of AH has been explored by successful test kit response and color change in toothpaste solution.

  6. Changes of the eye optics after iris constriction☆

    PubMed Central

    Montés-Micó, Robert; Hernández, Patricio; Fernández-Sánchez, Vicente; Bonaque, Sergio; Lara, Francisco; López-Gil, Norberto

    2011-01-01

    Purpose To evaluate the possible change in the optics of the human eye after iris constriction. Methods Ocular aberrations were measured under natural viewing conditions in 26 eyes. The measured eyes fixated on a dim target while the contralateral eye was either occluded (so the measured eye had a large pupil) or highly illuminated (so the measured eye had a small pupil). The measured eyes fixated to a dim target placed 0.5 D beyond the subject’s far point. Zernike values obtained in both situations were compared within the same pupil diameter corresponding to the one obtained under the high illumination condition. Results Significant variation in some aberration coefficients were found between the two illumination conditions. Specially, spherical aberration (SA) increased significantly after pupil miosis (P = .0017). The mean increase of SA measured was 0.018 microns, for a 3-mm pupil. Mean values of other ocular aberrations also vary significantly after pupil miosis (changes were larger than the standard deviation of the repeated measurements). A mean paraxial hyperopic shift of one third of diopter was found after iris constriction. Conclusion Iris constriction slightly modifies the optics of the eye. The small hyperopic shift of the best image plane after iris constriction may be explained by a change in the lens shape and/or position.

  7. [The eye, the optic system and its anomalies].

    PubMed

    Cohen, S Y

    1993-09-15

    The eye is a perceptive system with extremely complex physiology, although its optical properties can be assimilated to those of spherical diopters. Various approximations make it possible to reduce the eyeball to a single convex diopter. With a normal eye the image of an object situated ad infinitum focuses on the retina. The normal eye is called emmetropic. Otherwise, the eye is called ametropic. Several types of ametropy exist. When the image focuses in front of the retina the eye is said to be myopic. When the image focuses behind the retina the eye is called hypermetropic (or hyperopic). When the image of an object differs according to various focusing axes, the eye is said to be astigmatic.

  8. Longitudinal assessment of optical quality and intraocular scattering using the double-pass instrument in normal eyes and eyes with short tear breakup time.

    PubMed

    Kobashi, Hidenaga; Kamiya, Kazutaka; Yanome, Kyohei; Igarashi, Akihito; Shimizu, Kimiya

    2013-01-01

    To assess the longitudinal changes in optical quality including intraocular scattering in normal eyes and eyes with short tear breakup time (TBUT). We prospectively examined twenty eyes of 20 healthy subjects, and age-matched twenty eyes of 20 short TBUT subjects. The modulation transfer function (MTF) cutoff frequency, the Strehl ratio, and the objective scattering index (OSI) were quantitatively assessed using an Optical Quality Analysis System. We investigated the changes in these variables measured consecutively at the initial examination, 5, and 10 seconds without blinking. We also compared these variables in eyes with short TBUT with those in normal eyes. No significant differences in the MTF cutoff frequency, Strehl ratio, or OSI were detected over a 10-second period in normal eyes. These variables also became significantly degraded even over a 5-second period in eyes with short TBUT (p<0.01). We found significant differences in these variables at 5 and 10 seconds (p<0.05), but none immediately after the blink between normal and short TBUT eyes. Optical quality including intraocular scattering deteriorated significantly with time in eyes with short TBUT, whereas we found significant differences over a 10-second period in normal eyes. Eyes with short TBUT showed greater deterioration in optical quality after the blink than normal eyes. The longitudinal assessment of optical quality may be effective in distinguishing eyes with short TBUT from normal eyes.

  9. Multiconjugate adaptive optics applied to an anatomically accurate human eye model.

    PubMed

    Bedggood, P A; Ashman, R; Smith, G; Metha, A B

    2006-09-04

    Aberrations of both astronomical telescopes and the human eye can be successfully corrected with conventional adaptive optics. This produces diffraction-limited imagery over a limited field of view called the isoplanatic patch. A new technique, known as multiconjugate adaptive optics, has been developed recently in astronomy to increase the size of this patch. The key is to model atmospheric turbulence as several flat, discrete layers. A human eye, however, has several curved, aspheric surfaces and a gradient index lens, complicating the task of correcting aberrations over a wide field of view. Here we utilize a computer model to determine the degree to which this technology may be applied to generate high resolution, wide-field retinal images, and discuss the considerations necessary for optimal use with the eye. The Liou and Brennan schematic eye simulates the aspheric surfaces and gradient index lens of real human eyes. We show that the size of the isoplanatic patch of the human eye is significantly increased through multiconjugate adaptive optics.

  10. Evaluation of Internet websites about floaters and light flashes in patient education.

    PubMed

    Barbosa, Andréa Lima; Martins, Elisabeth Nogueira

    2007-01-01

    Flashes of light and floaters are most commonly caused by posterior vitreous separation but may be associated with sight-threatening disorders. Prevention of severe sequelae requires prompt dilated eye examination. Thus, information dissemination is crucial. This study aimed to evaluate the quality of information about floaters and light flashes available for patients on the Internet. Cross-sectional study. In July 2005 we evaluated information available on the Internet regarding floaters and light flashes, using two search engines (MetaCrawler and MSN) and three key terms ("floaters", "dark spots eye", and "light flashes eye"). The quality of each website was evaluated using a score system. The sites were classified as academic, organizational or commercial. Readability, general quality of the website (based on: ownership, purpose, authorship, author qualification, attribution, interactivity, and currency) and quality of the specific content (definition, causes, epidemiology, diagnosis, treatment, and prognosis) were analyzed. Of 145 websites evaluated, 49 were included. Four sites (8.2%) were academic, 9 (18.4%) organizational, and 36 (73.4%) commercial. In the majority of the sites (53.0%) information was poor and quality was not correlated with website classification. Information about floaters and light flashes available on the Internet is poor.

  11. Near-to-eye electroholography via guided-wave acousto-optics for augmented reality

    NASA Astrophysics Data System (ADS)

    Jolly, Sundeep; Savidis, Nickolaos; Datta, Bianca; Smalley, Daniel; Bove, V. Michael

    2017-03-01

    Near-to-eye holographic displays act to directly project wavefronts into a viewer's eye in order to recreate 3-D scenes for augmented or virtual reality applications. Recently, several solutions for near-to-eye electroholography have been proposed based on digital spatial light modulators in conjunction with supporting optics, such as holographic waveguides for light delivery; however, such schemes are limited by the inherent low space-bandwidth product available with current digital SLMs. In this paper, we depict a fully monolithic, integrated optical platform for transparent near-to-eye holographic display requiring no supporting optics. Our solution employs a guided-wave acousto-optic spatial light modulator implemented in lithium niobate in conjunction with an integrated Bragg-regime reflection volume hologram.

  12. A Compact Fiber Optic Eye Diagnostic System

    NASA Technical Reports Server (NTRS)

    Ansari, Rafat R.; Suh, Kwang I.; Dubin, Stephen; Dellavecchia, Michael A.

    1995-01-01

    A new fiber optic probe developed for determining transport properties of sub-micron particles in fluid experiments in a microgravity environment has been applied to study different parts of an eye. The probe positioned in front of an eye, delivers a low power (approximately few microW) light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like materials in the vitreous humor. In a clinical setting, the probe can be mounted on a standard slit-lamp apparatus simply using a Hruby lens holder. The capability of detecting cataracts, both nuclear and cortical, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before the surgery becomes necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber and their complications, e.g., posterior vitreous detachment and diabetic retinopathy.

  13. A Compact Fiber Optic Eye Diagnostics System

    NASA Technical Reports Server (NTRS)

    Ansari, Rafat R.; Suh, Kwang I.; DellaVecchia, Michael A.; Dubin, Stephen; Zigler, J. Samuel, Jr.

    1995-01-01

    A new fiber optic probe development for determining transport properties of sub-micron particles in fluids experiments in a microgravity environment has been applied to study different parts of the eye. The probe positioned in front of an eye, delivers a low power (approximately a few mu W) light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like material in the vitreous humor. For a clinical use, the probe is mounted on a standard slit-lamp apparatus simply using Hruby lens holder. The capability of detecting cataracts, both nuclear and cortical, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before the surgery becomes necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber and their complications, e.g., posterior vitreous detachment and diabetic retinopathy.

  14. An optical supernova associated with the X-ray flash XRF 060218.

    PubMed

    Pian, E; Mazzali, P A; Masetti, N; Ferrero, P; Klose, S; Palazzi, E; Ramirez-Ruiz, E; Woosley, S E; Kouveliotou, C; Deng, J; Filippenko, A V; Foley, R J; Fynbo, J P U; Kann, D A; Li, W; Hjorth, J; Nomoto, K; Patat, F; Sauer, D N; Sollerman, J; Vreeswijk, P M; Guenther, E W; Levan, A; O'Brien, P; Tanvir, N R; Wijers, R A M J; Dumas, C; Hainaut, O; Wong, D S; Baade, D; Wang, L; Amati, L; Cappellaro, E; Castro-Tirado, A J; Ellison, S; Frontera, F; Fruchter, A S; Greiner, J; Kawabata, K; Ledoux, C; Maeda, K; Møller, P; Nicastro, L; Rol, E; Starling, R

    2006-08-31

    Long-duration gamma-ray bursts (GRBs) are associated with type Ic supernovae that are more luminous than average and that eject material at very high velocities. Less-luminous supernovae were not hitherto known to be associated with GRBs, and therefore GRB-supernovae were thought to be rare events. Whether X-ray flashes--analogues of GRBs, but with lower luminosities and fewer gamma-rays--can also be associated with supernovae, and whether they are intrinsically 'weak' events or typical GRBs viewed off the axis of the burst, is unclear. Here we report the optical discovery and follow-up observations of the type Ic supernova SN 2006aj associated with X-ray flash XRF 060218. Supernova 2006aj is intrinsically less luminous than the GRB-supernovae, but more luminous than many supernovae not accompanied by a GRB. The ejecta velocities derived from our spectra are intermediate between these two groups, which is consistent with the weakness of both the GRB output and the supernova radio flux. Our data, combined with radio and X-ray observations, suggest that XRF 060218 is an intrinsically weak and soft event, rather than a classical GRB observed off-axis. This extends the GRB-supernova connection to X-ray flashes and fainter supernovae, implying a common origin. Events such as XRF 060218 are probably more numerous than GRB-supernovae.

  15. [Fluorescence property of a chemical probe for naked-eye and detection of Fe3+].

    PubMed

    Song, Yu-Min; Ma, Xin-Xian; Yang, Wu

    2012-12-01

    A higher selective and sensitive probe for the detection of Fe(III) in aqueous media was made using 2,4-Diisocyanatotoluene (TDI) as a bridge to couple Fe3 O4 nanoparticles(NPs) and Rhodamine-6G hydrazide. The characterization of composite materials with Infrared spectra(IR), Thermal Gravimetric analysis(TGA) and Transmission Emission Microscopy(TEM) points to the graft of Rhodamine-6G hydrazide onto the surface of the Fe3O4. The obvious color change of the probe solution from light grey to pink upon the addition of Fe3+ demonstrated the probe could be used for "naked-eye" detection of Fe3+ in water at pH 7. The presence of 1 equivalent (10 micromol x L(-1) microm) of each of these metal ions, including Mn2+, Ni2+, Y2+, Eu3+, Ce3+, La3+, Pr3+, Cd2+, Cr3+, Sm3+, Fe2+, Cu2+ and Zn2+ ions, did not demonstrate any obvious fluorescence change of the probe water solution, which confirmed the probe was a probe with remarkable selectivity for Fe3+. And the fluorescence images of HeLa cells in physiological solutions after incubation with Fe3+ and then further incubated with the probe leading to a strong intracellular fluorescence, which suggested the probe could penetrate the HeLa cell membrane and could respond to Fe3+ in intracellular within living cells.

  16. dlx and sp6-9 Control Optic Cup Regeneration in a Prototypic Eye

    PubMed Central

    Lapan, Sylvain W.; Reddien, Peter W.

    2011-01-01

    Optic cups are a structural feature of diverse eyes, from simple pit eyes to camera eyes of vertebrates and cephalopods. We used the planarian prototypic eye as a model to study the genetic control of optic cup formation and regeneration. We identified two genes encoding transcription factors, sp6-9 and dlx, that were expressed in the eye specifically in the optic cup and not the photoreceptor neurons. RNAi of these genes prevented formation of visible optic cups during regeneration. Planarian regeneration requires an adult proliferative cell population with stem cell-like properties called the neoblasts. We found that optic cup formation occurred only after migration of progressively differentiating progenitor cells from the neoblast population. The eye regeneration defect caused by dlx and sp6-9 RNAi can be explained by a failure to generate these early optic cup progenitors. Dlx and Sp6-9 genes function as a module during the development of diverse animal appendages, including vertebrate and insect limbs. Our work reveals a novel function for this gene pair in the development of a fundamental eye component, and it utilizes these genes to demonstrate a mechanism for total organ regeneration in which extensive cell movement separates new cell specification from organ morphogenesis. PMID:21852957

  17. Integrating the Advanced Human Eye Model (AHEM) and optical instrument models to model complete visual optical systems inclusive of the typical or atypical eye

    NASA Astrophysics Data System (ADS)

    Donnelly, William J., III

    2012-06-01

    PURPOSE: To present a commercially available optical modeling software tool to assist the development of optical instrumentation and systems that utilize and/or integrate with the human eye. METHODS: A commercially available flexible eye modeling system is presented, the Advanced Human Eye Model (AHEM). AHEM is a module that the engineer can use to perform rapid development and test scenarios on systems that integrate with the eye. Methods include merging modeled systems initially developed outside of AHEM and performing a series of wizard-type operations that relieve the user from requiring an optometric or ophthalmic background to produce a complete eye inclusive system. Scenarios consist of retinal imaging of targets and sources through integrated systems. Uses include, but are not limited to, optimization, telescopes, microscopes, spectacles, contact and intraocular lenses, ocular aberrations, cataract simulation and scattering, and twin eye model (binocular) systems. RESULTS: Metrics, graphical data, and exportable CAD geometry are generated from the various modeling scenarios.

  18. Modeling the Diffuse Cloud-Top Optical Emissions from Ground and Cloud Flashes

    NASA Technical Reports Server (NTRS)

    Solakiewicz, Richard; Koshak, William

    2008-01-01

    A number of studies have indicated that the diffuse cloud-top optical emissions from intra-cloud (IC) lightning are brighter than that from normal negative cloud-to-ground (CG) lightning, and hence would be easier to detect from a space-based sensor. The primary reason provided to substantiate this claim has been that the IC is at a higher altitude within the cloud and therefore is less obscured by the cloud multiple scattering medium. CGs at lower altitudes embedded deep within the cloud are more obscured, so CG detection is thought to be more difficult. However, other authors claim that because the CG source current (and hence luminosity) is typically substantially larger than IC currents, the greater CG source luminosity is large enough to overcome the effects of multiple scattering. These investigators suggest that the diffuse cloud top emissions from CGs are brighter than from ICs, and hence are easier to detect from space. Still other investigators claim that the detection efficiency of CGs and ICs is about the same because modern detector sensitivity is good enough to "see" either flash type no matter which produces a brighter cloud top emission. To better assess which of these opinions should be accepted, we introduce an extension of a Boltzmann lightning radiative transfer model previously developed. It considers characteristics of the cloud (geometry, dimensions, scattering properties) and specific lightning channel properties (length, geometry, location, current, optical wave front propagation speed/direction). As such, it represents the most detailed modeling effort to date. At least in the few cases studied thus far, it was found that IC flashes appear brighter at cloud top than the lower altitude negative ground flashes, but additional model runs are to be examined before finalizing our general conclusions.

  19. Temporal Binding Window of the Sound-Induced Flash Illusion in Amblyopia.

    PubMed

    Narinesingh, Cindy; Goltz, Herbert C; Wong, Agnes M F

    2017-03-01

    Amblyopia is a neurodevelopmental visual disorder caused by abnormal visual experience in childhood. In addition to known visual deficits, there is evidence for changes in audiovisual integration in amblyopia using explicit tasks. We examined audiovisual integration in amblyopia using an implicit task that is more relevant in a real-world context. A total of 11 participants with amblyopia and 16 controls were tested binocularly and monocularly on the sound-induced flash illusion, in which flashes and beeps are presented concurrently and the perceived number of flashes is influenced by the number of beeps. The task used 1 to 2 rapid peripheral flashes presented with 0 to 2 beeps, at 5 stimulus onset asynchronies, that is, beep (-200 milliseconds, -100 milliseconds) or flash leading (100 milliseconds, 200 milliseconds) or simultaneous (0 milliseconds). Participants reported the number of perceived flashes. Susceptibility was indicated by a "2 flashes" response to "fission" (1 flash, 2 beeps) or "1 flash" to "fusion" (2 flashes, 1 beep). For fission with the beep leading during binocular viewing, controls showed an expected decrease in illusion strength as stimulus onset asynchronies increased, whereas the illusion strength remained constant in participants with amblyopia, indicating a wider temporal binding window in amblyopia (P = 0.007). For fusion, participants with amblyopia showed reduced illusion strength during amblyopic eye viewing (P = 0.044) with the flash leading. Amblyopia is associated with the widening of the temporal binding window, specifically for fission when viewing binocularly with the beep leading. This suggests a developmental adaptation to delayed amblyopic eye visual processing to optimize audiovisual integration.

  20. A visual understanding of optical rotation using corn syrup

    NASA Astrophysics Data System (ADS)

    Nixon, M.; Hughes, I. G.

    2017-07-01

    In this paper a visual demonstration of optical rotation is presented, with content appropriate for use in a lecture demonstration as well as quantitative techniques suitable for an undergraduate-laboratory experiment. Linearly polarised lasers of various wavelengths are propagated through a glass tube containing corn syrup. The rotation of the plane of polarisation of the light is visible with the naked eye, making the experiment dramatic and engaging and aiding understanding of the phenomenon of optical rotation. In addition, we present a simple approach to quantitatively analyse data using only equipment commonly found in undergraduate teaching laboratories.

  1. Peripheral refraction with eye and head rotation with contact lenses.

    PubMed

    Lopes-Ferreira, Daniela P; Neves, Helena I F; Faria-Ribeiro, Miguel; Queirós, António; Fernandes, Paulo R B; González-Méijome, José M

    2015-04-01

    To evaluate the impact of eye and head rotation in the measurement of peripheral refraction with an open-field autorefractometer in myopic eyes wearing two different center-distance designs of multifocal contact lenses (MFCLs). Nineteen right eyes from 19 myopic patients (average central M ± SD = -2.67 ± 1.66 D) aged 20-27 years (mean ± SD = 23.2 ± 3.3 years) were evaluated using a Grand-Seiko autorefractometer. Patients were fitted with one multifocal aspheric center-distance contact lens (Biofinity Multifocal D(®)) and with one multi-concentric MFCL (Acuvue Oasys for Presbyopia). Axial and peripheral refraction were evaluated by eye rotation and by head rotation under naked eye condition and with each MFCL fitted randomly and in independent sessions. For the naked eye, refractive pattern (M, J0 and J45) across the central 60° of the horizontal visual field values did not show significant changes measured by rotating the eye or rotating the head (p > 0.05). Similar results were obtained wearing the Biofinity D, for both testing methods, no obtaining significant differences to M, J0 and J45 values (p > 0.05). For Acuvue Oasys for presbyopia, also no differences were found when comparing measurements obtained by eye and head rotation (p > 0.05). Multivariate analysis did not showed a significant interaction between testing method and lens type neither with measuring locations (MANOVA, p > 0.05). There were significant differences in M and J0 values between naked eyes and each MFCL. Measurements of peripheral refraction by rotating the eye or rotating the head in myopic patients wearing dominant design or multi-concentric multifocal silicone hydrogel contact lens are comparable. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  2. Retinitis pigmentosa inversa with unilateral high myopia with fellow eye optic disc pitting.

    PubMed

    Sheth, Saumil; Rush, Ryan; Narayanan, Raja

    2011-01-01

    To report a possible rare association of bilateral retinitis pigmentosa inversa (RPI) with unilateral high myopia with fellow eye optic disc pitting. A 55-year-old man with a history of reduced vision in the right eye since childhood presented with gradually decreasing vision in the left eye. On examination, a -23.00 diopter refractive error and diffuse chorioretinal atrophy consistent with pathologic myopia was found in the right eye. An optic disc pit with posterior pole pigmentary alterations thought to be consequent to a previous neurosensory detachment was found in the left eye. Though the retinal arteriolar attenuation seen in both eyes with an inconsistent history of night blindness since childhood pointed towards the possibility of a concurrently existing rod or rod-cone dystrophy, the posterior pole pigmentary alterations characteristic of RPI were clearly masked by the above pathologies. Optical coherence tomography demonstrated prominent foveal atrophy and an optic disc pit in the left eye. Electroretinography (ERG) demonstrated moderately attenuated amplitudes with prolonged implicit times of rod and cone responses bilaterally. The patient was diagnosed with bilateral RPI and anisometropic amblyopia in the right eye. This report documents a unique constellation of findings which include bilateral RPI and unilateral high myopia with an optic disc pit in the fellow eye. An ERG confirmation of a dystrophic etiology should be sought in suspicious cases, especially when findings are masked by the concurrent presence of other pathologies.

  3. Flash LIDAR Systems for Planetary Exploration

    NASA Astrophysics Data System (ADS)

    Dissly, Richard; Weinberg, J.; Weimer, C.; Craig, R.; Earhart, P.; Miller, K.

    2009-01-01

    Ball Aerospace offers a mature, highly capable 3D flash-imaging LIDAR system for planetary exploration. Multi mission applications include orbital, standoff and surface terrain mapping, long distance and rapid close-in ranging, descent and surface navigation and rendezvous and docking. Our flash LIDAR is an optical, time-of-flight, topographic imaging system, leveraging innovations in focal plane arrays, readout integrated circuit real time processing, and compact and efficient pulsed laser sources. Due to its modular design, it can be easily tailored to satisfy a wide range of mission requirements. Flash LIDAR offers several distinct advantages over traditional scanning systems. The entire scene within the sensor's field of view is imaged with a single laser flash. This directly produces an image with each pixel already correlated in time, making the sensor resistant to the relative motion of a target subject. Additionally, images may be produced at rates much faster than are possible with a scanning system. And because the system captures a new complete image with each flash, optical glint and clutter are easily filtered and discarded. This allows for imaging under any lighting condition and makes the system virtually insensitive to stray light. Finally, because there are no moving parts, our flash LIDAR system is highly reliable and has a long life expectancy. As an industry leader in laser active sensor system development, Ball Aerospace has been working for more than four years to mature flash LIDAR systems for space applications, and is now under contract to provide the Vision Navigation System for NASA's Orion spacecraft. Our system uses heritage optics and electronics from our star tracker products, and space qualified lasers similar to those used in our CALIPSO LIDAR, which has been in continuous operation since 2006, providing more than 1.3 billion laser pulses to date.

  4. Hypothesis on human eye perceiving optical spectrum rather than an image

    NASA Astrophysics Data System (ADS)

    Zheng, Yufeng; Szu, Harold

    2015-05-01

    It is a common knowledge that we see the world because our eyes can perceive an optical image. A digital camera seems a good example of simulating the eye imaging system. However, the signal sensing and imaging on human retina is very complicated. There are at least five layers (of neurons) along the signal pathway: photoreceptors (cones and rods), bipolar, horizontal, amacrine and ganglion cells. To sense an optical image, it seems that photoreceptors (as sensors) plus ganglion cells (converting to electrical signals for transmission) are good enough. Image sensing does not require ununiformed distribution of photoreceptors like fovea. There are some challenging questions, for example, why don't we feel the "blind spots" (never fibers exiting the eyes)? Similar situation happens to glaucoma patients who do not feel their vision loss until 50% or more nerves died. Now our hypothesis is that human retina initially senses optical (i.e., Fourier) spectrum rather than optical image. Due to the symmetric property of Fourier spectrum the signal loss from a blind spot or the dead nerves (for glaucoma patients) can be recovered. Eye logarithmic response to input light intensity much likes displaying Fourier magnitude. The optics and structures of human eyes satisfy the needs of optical Fourier spectrum sampling. It is unsure that where and how inverse Fourier transform is performed in human vision system to obtain an optical image. Phase retrieval technique in compressive sensing domain enables image reconstruction even without phase inputs. The spectrum-based imaging system can potentially tolerate up to 50% of bad sensors (pixels), adapt to large dynamic range (with logarithmic response), etc.

  5. Active eye-tracking for an adaptive optics scanning laser ophthalmoscope

    PubMed Central

    Sheehy, Christy K.; Tiruveedhula, Pavan; Sabesan, Ramkumar; Roorda, Austin

    2015-01-01

    We demonstrate a system that combines a tracking scanning laser ophthalmoscope (TSLO) and an adaptive optics scanning laser ophthalmoscope (AOSLO) system resulting in both optical (hardware) and digital (software) eye-tracking capabilities. The hybrid system employs the TSLO for active eye-tracking at a rate up to 960 Hz for real-time stabilization of the AOSLO system. AOSLO videos with active eye-tracking signals showed, at most, an amplitude of motion of 0.20 arcminutes for horizontal motion and 0.14 arcminutes for vertical motion. Subsequent real-time digital stabilization limited residual motion to an average of only 0.06 arcminutes (a 95% reduction). By correcting for high amplitude, low frequency drifts of the eye, the active TSLO eye-tracking system enabled the AOSLO system to capture high-resolution retinal images over a larger range of motion than previously possible with just the AOSLO imaging system alone. PMID:26203370

  6. A dual-responsive colorimetric and fluorescent chemosensor based on diketopyrrolopyrrole derivative for naked-eye detection of Fe3 + and its practical application

    NASA Astrophysics Data System (ADS)

    Zhang, Shanshan; Sun, Tao; Xiao, Dejun; Yuan, Fang; Li, Tianduo; Wang, Enhua; Liu, Haixia; Niu, Qingfen

    2018-01-01

    A novel dual-responsive colorimetric and fluorescent chemosensor L based on diketopyrrolopyrrole derivative for Fe3 + detection was designed and synthesized. In presence of Fe3 +, sensor L displayed strong colorimetric response as amaranth to rose pink and significant fluorescence enhancement and chromogenic change, which served as a naked-eye indicator by an obvious color change from purple to red. The binding constant for L-Fe3 + complex was found as 2.4 × 104 with the lower detection limit of 14.3 nM. The sensing mechanism was investigated in detail by fluorescence measurements, IR and 1H NMR spectra. Sensor L for Fe3 + detection also exhibited high anti-interference performance, good reversibility, wide pH response range and instantaneous response time. Furthermore, the sensor L has been used to quantify Fe3 + ions in practical water samples with good recovery.

  7. A rapid, naked-eye detection of hypochlorite and bisulfite using a robust and highly-photostable indicator dye Quinaldine Red in aqueous medium

    NASA Astrophysics Data System (ADS)

    Dutta, Tanoy; Chandra, Falguni; Koner, Apurba L.

    2018-02-01

    A ;naked-eye; detection of health hazardous bisulfite (HSO3-) and hypochlorite (ClO-) using an indicator dye (Quinaldine Red, QR) in a wide range of pH is demonstrated. The molecule contains a quinoline moiety linked to an N,N-dimethylaniline moiety with a conjugated double bond. Treatment of QR with HSO3- and ClO-, in aqueous solution at near-neutral pH, resulted in a colorless product with high selectivity and sensitivity. The detection limit was 47.8 μM and 0.2 μM for HSO3- and ClO- respectively. However, ClO- was 50 times more sensitive and with 2 times faster response compared to HSO3-. The detail characterization and related analysis demonstrate the potential of QR for a rapid, robust and highly efficient colorimetric sensor for the practical applications to detect hypochlorite in water samples.

  8. The bright optical flash and afterglow from the gamma-ray burst GRB 130427A.

    PubMed

    Vestrand, W T; Wren, J A; Panaitescu, A; Wozniak, P R; Davis, H; Palmer, D M; Vianello, G; Omodei, N; Xiong, S; Briggs, M S; Elphick, M; Paciesas, W; Rosing, W

    2014-01-03

    The optical light generated simultaneously with x-rays and gamma rays during a gamma-ray burst (GRB) provides clues about the nature of the explosions that occur as massive stars collapse. We report on the bright optical flash and fading afterglow from powerful burst GRB 130427A. The optical and >100-megaelectron volt (MeV) gamma-ray flux show a close correlation during the first 7000 seconds, which is best explained by reverse shock emission cogenerated in the relativistic burst ejecta as it collides with surrounding material. At later times, optical observations show the emergence of emission generated by a forward shock traversing the circumburst environment. The link between optical afterglow and >100-MeV emission suggests that nearby early peaked afterglows will be the best candidates for studying gamma-ray emission at energies ranging from gigaelectron volts to teraelectron volts.

  9. Micrometric Control of the Optics of the Human Eye: Environment or Genes?

    PubMed

    Tabernero, Juan; Hervella, Lucía; Benito, Antonio; Colodro-Conde, Lucía; Ordoñana, Juan R; Ruiz-Sanchez, Marcos; Marín, José María; Artal, Pablo

    2017-04-01

    The human eye has typically more optical aberrations than conventional artificial optical systems. While the lower order modes (defocus and astigmatism) are well studied, our purpose is to explore the influence of genes versus the environment on the higher order aberrations of the optical components of the eye. We have performed a classical twin study in a sample from the Region of Murcia (Spain). Optical aberrations using a Hartmann-Shack sensor (AOnEye Voptica SL, Murcia, Spain) and corneal aberrations (using corneal topography data) were measured in 138 eyes corresponding to 69 twins; 36 monozygotic (MZ) and 33 dizygotic (DZ) pairs (age 55 years, SD 7 years). Intraclass correlation coefficients (ICCs) were used to estimate how strongly aberrations of twins resemble each other, and genetic models were fitted to quantify heritability in the selected phenotypes. Genes had a significant influence in the variance of most of the higher order aberration terms (heritability from 40% to 70%). This genetic influence was observed similarly in both cornea and complete eye aberrations. Additionally, the compensation factor of spherical aberration in the eye (i.e., how much corneal spherical aberration was compensated by internal spherical aberration) was found under genetic influence (heritability of 68%). There is a significant genetic contribution to the variance of aberrations of the eye, not only at macroscopic levels, as in myopia or astigmatism, but also at microscopic levels, where a few micrometers changes in surface topography can produce a large difference in the value of the optical aberrations.

  10. High-speed adaptive optics line scan confocal retinal imaging for human eye.

    PubMed

    Lu, Jing; Gu, Boyu; Wang, Xiaolin; Zhang, Yuhua

    2017-01-01

    Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye's optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss.

  11. Neurophysiological intraoperative monitoring during an optic nerve schwannoma removal.

    PubMed

    San-Juan, Daniel; Escanio Cortés, Manuel; Tena-Suck, Martha; Orozco Garduño, Adolfo Josué; López Pizano, Jesús Alejandro; Villanueva Domínguez, Jonathan; Fernández Gónzalez-Aragón, Maricarmen; Gómez-Amador, Juan Luis

    2017-10-01

    This paper reports the case of a patient with optic nerve schwannoma and the first use of neurophysiological intraoperative monitoring of visual evoked potentials during the removal of such tumor with no postoperative visual damage. Schwannomas are benign neoplasms of the peripheral nervous system arising from the neural crest-derived Schwann cells, these tumors are rarely located in the optic nerve and the treatment consists on surgical removal leading to high risk of damage to the visual pathway. Case report of a thirty-year-old woman with an optic nerve schwannoma. The patient underwent surgery for tumor removal on the left optic nerve through a left orbitozygomatic approach with intraoperative monitoring of left II and III cranial nerves. We used Nicolet Endeavour CR IOM (Carefusion, Middleton WI, USA) to performed visual evoked potentials stimulating binocularly with LED flash goggles with the patient´s eyes closed and direct epidural optic nerve stimulation delivering rostral to the tumor a rectangular current pulse. At follow up examinations 7 months later, the left eye visual acuity was 20/60; Ishihara score was 8/8 in both eyes; the right eye photomotor reflex was normal and left eye was mydriatic and arreflectic; optokinetic reflex and ocular conjugate movements were normal. In this case, the epidural direct electrical stimulation of optic nerve provided stable waveforms during optic nerve schwannoma resection without visual loss.

  12. Optical coherence tomography measurement of the retinal nerve fiber layer in normal and juvenile glaucomatous eyes.

    PubMed

    Mrugacz, Malgorzata; Bakunowicz-Lazarczyk, Alina

    2005-01-01

    The aim of this study was to quantitatively assess and compare the thickness of the retinal nerve fiber layer (RNFL) in normal and glaucomatous eyes of children using the optical coherence tomograph. The mean RNFL thickness of normal eyes (n=26) was compared with that of glaucomatous eyes (n=26). The eyes were classified into diagnostic groups based on conventional ophthalmological physical examination, Humphrey 30-2 visual fields, stereoscopic optic nerve head photography, and optical coherence tomography. The mean RNFL was significantly thinner in glaucomatous eyes than in normal eyes: 95+/-26.3 and 132+/-24.5 microm, respectively. More specifically, the RNFL was significantly thinner in glaucomatous eyes than in normal eyes in the inferior quadrant: 87+/-23.5 and 122+/-24.2 microm, respectively. The mean and inferior quadrant RFNL thicknesses as measured by the optical coherence tomograph showed a statistically significant correlation with glaucoma. Optical coherence tomography may contribute to tracking of juvenile glaucoma progression. Copyright (c) 2005 S. Karger AG, Basel.

  13. A colorimetric turn-on optical chemosensor for Cu2+ ions and its application as solid state sensor

    NASA Astrophysics Data System (ADS)

    Pannipara, Mehboobali; Al-Sehemi, Abdullah G.; Assiri, Mohammed; Kalam, Abul

    2018-05-01

    We report a novel coumarin based optical chemosensor (Probe 1) for the selective and sensitive detection of Cu2+ ions in aqueous medium. The addition of Cu2+ ions to Probe 1 shows distinct color change from light yellow to pinkish red color under visible light with the sensing limit of 1.54 μM. Moreover, practical utility of Probe 1 as solid state optical sensor (test paper, TLC plates) for sensing Cu2+ has been demonstrated by instantaneous "naked eye" response.

  14. Double peacock eye optical element for extended focal depth imaging with ophthalmic applications.

    PubMed

    Romero, Lenny A; Millán, María S; Jaroszewicz, Zbigniew; Kolodziejczyk, Andrzej

    2012-04-01

    The aged human eye is commonly affected by presbyopia, and therefore, it gradually loses its capability to form images of objects placed at different distances. Extended depth of focus (EDOF) imaging elements can overcome this inability, despite the introduction of a certain amount of aberration. This paper evaluates the EDOF imaging performance of the so-called peacock eye phase diffractive element, which focuses an incident plane wave into a segment of the optical axis and explores the element's potential use for ophthalmic presbyopia compensation optics. Two designs of the element are analyzed: the single peacock eye, which produces one focal segment along the axis, and the double peacock eye, which is a spatially multiplexed element that produces two focal segments with partial overlapping along the axis. The performances of the peacock eye elements are compared with those of multifocal lenses through numerical simulations as well as optical experiments in the image space. The results demonstrate that the peacock eye elements form sharper images along the focal segment than the multifocal lenses and, therefore, are more suitable for presbyopia compensation. The extreme points of the depth of field in the object space, which represent the remote and the near object points, have been experimentally obtained for both the single and the double peacock eye optical elements. The double peacock eye element has better imaging quality for relatively short and intermediate distances than the single peacock eye, whereas the latter seems better for far distance vision.

  15. Naked singularity resolution in cylindrical collapse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurita, Yasunari; Yukawa Institute for Theoretical Physics, Kyoto University, Kyoto, 606-8502; Nakao, Ken-ichi

    In this paper, we study the gravitational collapse of null dust in cylindrically symmetric spacetime. The naked singularity necessarily forms at the symmetry axis. We consider the situation in which null dust is emitted again from the naked singularity formed by the collapsed null dust and investigate the backreaction by this emission for the naked singularity. We show a very peculiar but physically important case in which the same amount of null dust as that of the collapsed one is emitted from the naked singularity as soon as the ingoing null dust hits the symmetry axis and forms the nakedmore » singularity. In this case, although this naked singularity satisfies the strong curvature condition by Krolak (limiting focusing condition), geodesics which hit the singularity can be extended uniquely across the singularity. Therefore, we may say that the collapsing null dust passes through the singularity formed by itself and then leaves for infinity. Finally, the singularity completely disappears and the flat spacetime remains.« less

  16. Computing Optic Flow with ArduEye Vision Sensor

    DTIC Science & Technology

    2013-01-01

    processing algorithm that can be applied to the flight control of other robotic platforms. 15. SUBJECT TERMS Optical flow, ArduEye, vision based ...2 Figure 2. ArduEye vision chip on Stonyman breakout board connected to Arduino Mega (8) (left) and the Stonyman vision chips (7...robotic platforms. There is a significant need for small, light , less power-hungry sensors and sensory data processing algorithms in order to control the

  17. Coincidental Optic Nerve Meningioma and Thyroid Eye Disease.

    PubMed

    Garg, Aakriti; Patel, Payal; Lignelli, Angela; Baron, Edward; Kazim, Michael

    2015-01-01

    A 57-year-old woman with diabetes mellitus, hypertension, obesity, and Graves disease presented with clinical evidence of thyroid eye disease (TED) and optic neuropathy. She was referred when a tapered dose of steroids prompted worsening of her TED. CT and MRI were consistent with TED and bilateral optic nerve meningioma. To the authors' knowledge, this is the first reported case of concurrent TED and unsuspected bilateral optic nerve meningioma. When investigating the etiology of TED-associated optic neuropathy, careful attention to orbital imaging is required because coexisting pathology may exist.

  18. Periodicity analysis on cat-eye reflected beam profiles of optical detectors

    NASA Astrophysics Data System (ADS)

    Gong, Mali; He, Sifeng

    2017-05-01

    The cat-eye effect reflected beam profiles of most optical detectors have a certain characteristic of periodicity, which is caused by array arrangement of sensors at their optical focal planes. It is the first time to find and prove that the reflected beam profile becomes several periodic spots at the reflected propagation distance corresponding to half the imaging distance of a CCD camera. Furthermore, the spatial cycle of these spots is approximately constant, independent of the CCD camera's imaging distance, which is related only to the focal length and pixel size of the CCD sensor. Thus, we can obtain the imaging distance and intrinsic parameters of the optical detector by analyzing its cat-eye reflected beam profiles. This conclusion can be applied in the field of non-cooperative cat-eye target recognition.

  19. Comparison of two methods of visual magnification for removal of adhesive flash during bracket placement using two types of orthodontic bonding agents

    PubMed Central

    Alencar, Estefania Queiroga de Santana e; Nobrega, Maria de Lourdes Martins; Dametto, Fabio Roberto; dos Santos, Patrícia Bittencourt Dutra; Pinheiro, Fabio Henrique de Sá Leitão

    2016-01-01

    ABSTRACT Objective: This study aimed to evaluate the effectiveness of two methods of visual magnification (operating microscope and light head magnifying glass) for removal of composite flash around orthodontic metal brackets. Material and Methods: Brackets were bonded in the center of the clinical crown of sixty well-preserved human premolars. Half of the sample was bonded with conventional Transbond XT (3M Unitek TM, USA), whereas the other half was bonded with Transbond TM Plus Color Change (3M Unitek TM, USA). For each type of composite, the choice of method to remove the flash was determined by randomly distributing the teeth into the following subgroups: A (removal by naked eye, n = 10), B (removal with the aid of light head magnifying glass, under 4x magnification, n = 10), and C (removal with the aid of an operating microscope, under 40x magnification, n = 10). Brackets were debonded and teeth taken to a scanning electron microscope (SS-x-550, Shimadzu, Japan) for visualization of their buccal surface. Quantification of composite flash was performed with Image Pro Plus software, and values were compared by Kruskal-Wallis test and Dunn’s post-hoc test at 5% significance level. Results: Removal of pigmented orthodontic adhesive with the aid of light head magnifying glass proved, in general, to be advantageous in comparison to all other methods. Conclusion: There was no advantage in using Transbond TM Plus Color Change alone. Further studies are necessary to draw a more definitive conclusion in regards to the benefits of using an operating microscope. PMID:28125139

  20. Optical countermeasures against CLOS weapon systems

    NASA Astrophysics Data System (ADS)

    Toet, Alexander; Benoist, Koen W.; van Lingen, Joost N. J.; Schleijpen, H. Ric M. A.

    2013-10-01

    There are many weapon systems in which a human operator acquires a target, tracks it and designates it. Optical countermeasures against this type of systems deny the operator the possibility to fulfill this visual task. We describe the different effects that result from stimulation of the human visual system with high intensity (visible) light, and the associated potential operational impact. Of practical use are flash blindness, where an intense flash of light produces a temporary "blind-spot" in (part of) the visual field, flicker distraction, where strong intensity and/or color changes at a discomfortable frequency are produced, and disability glare where a source of light leads to contrast reduction. Hence there are three possibilities to disrupt the visual task of an operator with optical countermeasures such as flares or lasers or a combination of these; namely, by an intense flash of light, by an annoying light flicker or by a glare source. A variety of flares for this purpose is now available or under development: high intensity flash flares, continuous burning flares or strobe flares which have an oscillating intensity. The use of flare arrays seems particularly promising as an optical countermeasure. Lasers are particularly suited to interfere with human vision, because they can easily be varied in intensity, color and size, but they have to be directed at the (human) target, and issues like pointing and eye-safety have to be taken into account. Here we discuss the design issues and the operational impact of optical countermeasures against human operators.

  1. Flashes and floaters - a practical approach to assessment and management.

    PubMed

    Kahawita, Shyalle; Simon, Sumu; Gilhotra, Jolly

    2014-04-01

    Flashes and floaters are common ophthalmic issues for which patients may initially present to their general practitioner. It may be a sign of benign, 
age-related changes of the vitreous or more serious retinal detachment. This article provides a guide to the assessment and management of a patient presenting with flashes and floaters. Although most patients presenting with flashes and floaters have benign 
age-related changes, they must be referred to an ophthalmologist to rule out sight-threatening conditions. Key examination features include the nature of the flashes and floaters, whether one or both eyes are affected and changes in visual acuity or visual field.

  2. Modeling the influence of LASIK surgery on optical properties of the human eye

    NASA Astrophysics Data System (ADS)

    Szul-Pietrzak, Elżbieta; Hachoł, Andrzej; Cieślak, Krzysztof; Drożdż, Ryszard; Podbielska, Halina

    2011-11-01

    The aim was to model the influence of LASIK surgery on the optical parameters of the human eye and to ascertain which factors besides the central corneal radius of curvature and central thickness play the major role in postsurgical refractive change. Ten patients were included in the study. Pre- and postsurgical measurements included standard refraction, anterior corneal curvature and pachymetry. The optical model used in the analysis was based on the Le Grand and El Hage schematic eye, modified by the measured individual parameters of corneal geometry. A substantial difference between eye refractive error measured after LASIK and estimated from the eye model was observed. In three patients, full correction of the refractive error was achieved. However, analysis of the visual quality in terms of spot diagrams and optical transfer functions of the eye optical system revealed some differences in these measurements. This suggests that other factors besides corneal geometry may play a major role in postsurgical refraction. In this paper we investigated whether the biomechanical properties of the eyeball and changes in intraocular pressure could account for the observed discrepancies.

  3. Wavefront sensorless adaptive optics ophthalmoscopy in the human eye

    PubMed Central

    Hofer, Heidi; Sredar, Nripun; Queener, Hope; Li, Chaohong; Porter, Jason

    2011-01-01

    Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the wavefront sensor ‘beacon’ can interfere with visual experiments. We demonstrate real-time (25 Hz), wavefront sensorless adaptive optics imaging in the living human eye with image quality rivaling that of wavefront sensor based control in the same system. A stochastic parallel gradient descent algorithm directly optimized the mean intensity in retinal image frames acquired with a confocal adaptive optics scanning laser ophthalmoscope (AOSLO). When imaging through natural, undilated pupils, both control methods resulted in comparable mean image intensities. However, when imaging through dilated pupils, image intensity was generally higher following wavefront sensor-based control. Despite the typically reduced intensity, image contrast was higher, on average, with sensorless control. Wavefront sensorless control is a viable option for imaging the living human eye and future refinements of this technique may result in even greater optical gains. PMID:21934779

  4. Macular retinoschisis in eyes with glaucomatous optic neuropathy: Vitrectomy and natural course.

    PubMed

    Yoshikawa, Tadanobu; Yamanaka, Chihiro; Kinoshita, Takamasa; Morikawa, Shohei; Ogata, Nahoko

    2018-02-01

    Our purpose was to determine the effectiveness of vitrectomy in resolving the macular retinoschisis in an eye with glaucomatous optic neuropathy and also to determine the natural course of macular retinoschisis. This was a retrospective case series of patients who were diagnosed with macular retinoschisis and glaucomatous optic neuropathy. Fourteen eyes of 13 patients were studied. Patients with high myopia, vitreomacular traction syndrome, and the pit macular syndrome were excluded. There were three men and ten women, and 12 had unilateral and one had bilateral macular retinoschisis. Vitrectomy was performed for a serous retinal detachment, macular hole, or severe visual loss in five eyes. The mean follow-up time was 68.8 months in these five eyes, and the macular retinoschisis was resolved and the best-corrected visual acuity (BCVA) at the final visit was significantly improved in all eyes (P = 0.007). However, two of these fiv e eyes developed a macular hole and required a second vitrectomy. Of the nine eyes without treatment with a mean follow-up time of 29.0 months, the BCVA at the final visit remained unchanged from the baseline BCVA in all eyes. The macular retinoschisis was resolved or reduced in three eyes without treatment. Vitrectomy was effective for the resolution of macular retinoschisis in eyes with glaucomatous optic neuropathy and serous retinal detachment or macular hole or severe reduction of the BCVA. Macular retinoschisis can be resolved without a reduction of the BCVA in some cases without treatment.

  5. Naked singularity, firewall, and Hawking radiation.

    PubMed

    Zhang, Hongsheng

    2017-06-21

    Spacetime singularity has always been of interest since the proof of the Penrose-Hawking singularity theorem. Naked singularity naturally emerges from reasonable initial conditions in the collapsing process. A recent interesting approach in black hole information problem implies that we need a firewall to break the surplus entanglements among the Hawking photons. Classically, the firewall becomes a naked singularity. We find some vacuum analytical solutions in R n -gravity of the firewall-type and use these solutions as concrete models to study the naked singularities. By using standard quantum theory, we investigate the Hawking radiation emitted from the black holes with naked singularities. Here we show that the singularity itself does not destroy information. A unitary quantum theory works well around a firewall-type singularity. We discuss the validity of our result in general relativity. Further our result demonstrates that the temperature of the Hawking radiation still can be expressed in the form of the surface gravity divided by 2π. This indicates that a naked singularity may not compromise the Hakwing evaporation process.

  6. Eye investigation with optical microradar techniques

    NASA Astrophysics Data System (ADS)

    Molebny, Vasyl V.; Pallikaris, Ioannis G.; Naoumidis, Leonidas P.; Kurashov, Vitalij N.; Chyzh, Igor H.

    1997-08-01

    Many problems exist in ophthalmology, where accurate measurements of eye structure and its parameters can be provided using optical radar concept is of remote sensing. Coherent and non-coherent approaches are reviewed aiming cornea shape measurement and measurement of aberration distribution in the elements and media of an eye. Coherent radar techniques are analyzed taking into account non- reciprocity of eye media and anisoplanatism of the fovea, that results in an exiting image being not an auto- correlation of the point-spread function of a single pass, even in the approximation of spatial invariance of the system. It is found, that aberrations of the cornea and lens are not additive, and may not be brought to summary aberrations on the entrance aperture of the lens. Anisoplanatism of the fovea and its roughness lead to low degree of coherence in scattered light. To estimate the result of measurements, methodology has been developed using Zernike polynomials expansions. Aberration distributions were gotten from measurements in 16 points of an eye situated on two concentric circles. Wave aberration functions have been approximated using least-square criterion. Thus, all data were provided necessary for cornea ablation with PRK procedure.

  7. High-speed adaptive optics line scan confocal retinal imaging for human eye

    PubMed Central

    Wang, Xiaolin; Zhang, Yuhua

    2017-01-01

    Purpose Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. Methods A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye’s optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. Results The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. Conclusions We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss. PMID:28257458

  8. The impact of red light running camera flashes on younger and older drivers' attention and oculomotor control.

    PubMed

    Wright, Timothy J; Vitale, Thomas; Boot, Walter R; Charness, Neil

    2015-12-01

    Recent empirical evidence has suggested that the flashes associated with red light running cameras (RLRCs) distract younger drivers, pulling attention away from the roadway and delaying processing of safety-relevant events. Considering the perceptual and attentional declines that occur with age, older drivers may be especially susceptible to the distracting effects of RLRC flashes, particularly in situations in which the flash is more salient (a bright flash at night compared with the day). The current study examined how age and situational factors potentially influence attention capture by RLRC flashes using covert (cuing effects) and overt (eye movement) indices of capture. We manipulated the salience of the flash by varying its luminance and contrast with respect to the background of the driving scene (either day or night scenes). Results of 2 experiments suggest that simulated RLRC flashes capture observers' attention, but, surprisingly, no age differences in capture were observed. However, an analysis examining early and late eye movements revealed that older adults may have been strategically delaying their eye movements in order to avoid capture. Additionally, older adults took longer to disengage attention following capture, suggesting at least 1 age-related disadvantage in capture situations. Findings have theoretical implications for understanding age differences in attention capture, especially with respect to capture in real-world scenes, and inform future work that should examine how the distracting effects of RLRC flashes influence driver behavior. (c) 2015 APA, all rights reserved).

  9. The Impact of Red Light Running Camera Flashes on Younger and Older Drivers' Attention and Oculomotor Control

    PubMed Central

    Wright, Timothy J.; Vitale, Thomas; Boot, Walter R; Charness, Neil

    2015-01-01

    Recent empirical evidence suggests that the flashes associated with red light running cameras (RLRCs) distract younger drivers, pulling attention away from the roadway and delaying processing of safety-relevant events. Considering the perceptual and attentional declines that occur with age, older drivers may be especially susceptible to the distracting effects of RLRC flashes, particularly in situations in which the flash is more salient (a bright flash at night compared to the day). The current study examined how age and situational factors potentially influence attention capture by RLRC flashes using covert (cuing effects) and overt (eye movement) indices of capture. We manipulated the salience of the flash by varying its luminance and contrast with respect to the background of the driving scene (either day or night scenes). Results of two experiments suggest that simulated RLRC flashes capture observers' attention, but, surprisingly, no age differences in capture were observed. However, an analysis examining early and late eye movements revealed that older adults may have been strategically delaying their eye movements in order to avoid capture. Additionally, older adults took longer to disengage attention following capture, suggesting at least one age-related disadvantage in capture situations. Findings have theoretical implications for understanding age differences in attention capture, especially with respect to capture in real-world scenes, and inform future work that should examine how the distracting effects of RLRC flashes influence driver behavior. PMID:26479014

  10. Optical clearing of the eye using the See Deep Brain technique.

    PubMed

    Hohberger, B; Baumgart, C; Bergua, A

    2017-10-01

    PurposeTissue clearing has been used in anatomy for the first time in Germany over a century ago. Neuronal tissue, like cortex, was investigated in mice using a water-based optical clearing method termed See Deep Brain (SeeDB). However, although the eye belongs to the central nervous system, this histological technique was not applied in the eye up to date. We applied SeeDB for the visualization of intraocular structures.Patients and methodsFour eyes of cornea donors (two male, two female: 73-84 years) obtained from the Cornea Bank of the Department of Ophthalmology Erlangen, four chicken eyes and two mices' optic nerve were used. Bulbi were fixed in 4% paraformaldehyde in phosphate-buffered saline and treated with increasing concentrations of aqueous fructose solution with 0.5% α-thioglycerol. After SeeDB, transscleral macrophotographs of the choroid were performed.ResultsComplete transparency of the sclera was obtained in enucleated human and chicken eyes after SeeDB treatment. Macroscopical anatomy of the choroid (partially transparent due to the remaining retinal pigment epithelium and melanocytes) showing vessels and other related structures was possible without preparing slides. Mice optic nerves were also transparent after SeeDB treatment.ConclusionThe SeeDB method allows visualization of intraocular structures through a completely translucent sclera. This innovative processing technique could facilitate comprehensive qualitative and quantitative topographical anatomical studies of human and animal eyes, preserving their 3D architecture. Supra- and intrachoroidal ganglionic plexus could potentially be visualized transsclerally. Finally, clinical-pathological correlations of intraocular diseases-for example, retinal tumors-will be possible in non-dissected eyes.

  11. A dual-responsive colorimetric and fluorescent chemosensor based on diketopyrrolopyrrole derivative for naked-eye detection of Fe3+ and its practical application.

    PubMed

    Zhang, Shanshan; Sun, Tao; Xiao, Dejun; Yuan, Fang; Li, Tianduo; Wang, Enhua; Liu, Haixia; Niu, Qingfen

    2018-01-15

    A novel dual-responsive colorimetric and fluorescent chemosensor L based on diketopyrrolopyrrole derivative for Fe 3+ detection was designed and synthesized. In presence of Fe 3+ , sensor L displayed strong colorimetric response as amaranth to rose pink and significant fluorescence enhancement and chromogenic change, which served as a naked-eye indicator by an obvious color change from purple to red. The binding constant for L-Fe 3+ complex was found as 2.4×10 4 with the lower detection limit of 14.3nM. The sensing mechanism was investigated in detail by fluorescence measurements, IR and 1 H NMR spectra. Sensor L for Fe 3+ detection also exhibited high anti-interference performance, good reversibility, wide pH response range and instantaneous response time. Furthermore, the sensor L has been used to quantify Fe 3+ ions in practical water samples with good recovery. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Questions Students Ask: The Red-Eye Effect.

    ERIC Educational Resources Information Center

    Physics Teacher, 1985

    1985-01-01

    Addresses the question of why a dog's eyes appear red and glow when a flash photograph is taken. Conditions for the red-eye effect, light paths involved, structure of the eye, and typical cameras and lenses are discussed. Also notes differences between the eyes of nocturnal animals and humans. (JN)

  13. Inter-eye Asymmetry of Optical Coherence Tomography Angiography Vessel Density in Bilateral Glaucoma, Glaucoma Suspect, and Healthy Eyes.

    PubMed

    Hou, Huiyuan; Moghimi, Sasan; Zangwill, Linda M; Shoji, Takuhei; Ghahari, Elham; Manalastas, Patricia Isabel C; Penteado, Rafaella C; Weinreb, Robert N

    2018-03-23

    To investigate inter-eye retinal vessel density asymmetry in healthy, glaucoma suspect, and mild to moderate glaucoma subjects, and its potential utility for early detection of glaucomatous damage. Cross-sectional study. 153 subjects including 55 healthy, 32 glaucoma suspect, and 66 glaucoma subjects enrolled in the Diagnostic Innovations in Glaucoma Study(DIGS). Vessel density was obtained from optical coherence tomography angiography (OCT-A) macular and optic nerve head scans. Thickness of peripapillary retinal nerve fiber layer (RNFL) and macular ganglion cell complex (mGCC) was measured with spectral-domain optical coherence tomography (SD-OCT) scans. Inter-eye asymmetry was calculated by taking the absolute value of difference in vessel density and thickness between the right and left eyes. Inter-eye retinal vessel density asymmetry parameters were significantly different among the three groups. Glaucoma suspects had significantly higher peripapillary and macular inter-eye vessel density asymmetries compared to healthy groups in univariate (1.1% vs. 2.0%, P=0.014 and 1.2% vs. 2.5%, P=0.027, respectively) and multivariate analyses (P=0.007 and 0.038, respectively). No significant differences in asymmetry of thickness parameters were found between glaucoma suspect and healthy groups (all P> 0.718). However significant differences in asymmetry of thickness parameters between glaucoma suspects and glaucoma patients (P<0.01) were found for all parameters. Inter-eye vessel density asymmetry can be quantified by OCT-A measurement. Glaucoma suspects have significantly greater vessel density asymmetry than healthy eyes. Longitudinal studies are needed to better characterize the relationship of vessel density asymmetry with the development and progression of glaucoma. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Obtaining the Grobner Initialization for the Ground Flash Fraction Retrieval Algorithm

    NASA Technical Reports Server (NTRS)

    Solakiewicz, R.; Attele, R.; Koshak, W.

    2011-01-01

    At optical wavelengths and from the vantage point of space, the multiple scattering cloud medium obscures one's view and prevents one from easily determining what flashes strike the ground. However, recent investigations have made some progress examining the (easier, but still difficult) problem of estimating the ground flash fraction in a set of N flashes observed from space In the study by Koshak, a Bayesian inversion method was introduced for retrieving the fraction of ground flashes in a set of flashes observed from a (low earth orbiting or geostationary) satellite lightning imager. The method employed a constrained mixed exponential distribution model to describe the lightning optical measurements. To obtain the optimum model parameters, a scalar function of three variables (one of which is the ground flash fraction) was minimized by a numerical method. This method has formed the basis of a Ground Flash Fraction Retrieval Algorithm (GoFFRA) that is being tested as part of GOES-R GLM risk reduction.

  15. FLASH2: Operation, beamlines, and photon diagnostics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plönjes, Elke, E-mail: elke.ploenjes@desy.de; Faatz, Bart; Kuhlmann, Marion

    2016-07-27

    FLASH2, a major extension of the soft X-ray free-electron laser FLASH at DESY, turns FLASH into a multi-user FEL facility. A new undulator line is located in a separate accelerator tunnel and driven additionally by the FLASH linear accelerator. First lasing of FLASH2 was achieved in August 2014 with simultaneous user operation at FLASH1. The new FLASH2 experimental hall offers space for up to six experimental end stations, some of which will be installed permanently. The wide wavelength range spans from 4-60 nm and 0.8 nm in the 5{sup th} harmonic and in the future deep into the water windowmore » in the fundamental. While this is of high interest to users, it is challenging from the beamline instrumentation point of view. Online diagnostics - which are mostly pulse resolved - for beam intensity, position, wavelength, wave front, and pulse length have been to a large extent developed at FLASH(1) and have now been optimized for FLASH2. Pump-probe facilities for XUV-XUV, XUV optical and XUV-THz experiments will complete the FLASH2 user facility.« less

  16. Naked singularities as particle accelerators. II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patil, Mandar; Joshi, Pankaj S.; Malafarina, Daniele

    We generalize here our earlier results on particle acceleration by naked singularities. We showed recently [M. Patil and P. S. Joshi, Phys. Rev. D 82, 104049 (2010).] that the naked singularities that form due to the gravitational collapse of massive stars provide a suitable environment where particles could get accelerated and collide at arbitrarily high center-of-mass energies. However, we focused there only on the spherically symmetric gravitational collapse models, which were also assumed to be self-similar. In this paper, we broaden and generalize the result to all gravitational collapse models leading to the formation of a naked singularity as themore » final state of collapse, evolving from a regular initial data, without making any prior restrictive assumptions about the spacetime symmetries such as above. We show that, when the particles interact and collide near the Cauchy horizon, the energy of collision in the center-of-mass frame will be arbitrarily high, thus offering a window to the Planck scale physics. We also consider the issue of various possible physical mechanisms of generation of such very high-energy particles from the vicinity of naked singularity. We then construct a model of gravitational collapse to a timelike naked singularity to demonstrate the working of these ideas, where the pressure is allowed to be negative, but the energy conditions are respected. We show that a finite amount of mass-energy density has to be necessarily radiated away from the vicinity of the naked singularity as the collapse evolves. Therefore, the nature of naked singularities, both at the classical and quantum level, could play an important role in the process of particle acceleration, explaining the occurrence of highly energetic outgoing particles in the vicinity of the Cauchy horizon that participate in extreme high-energy collisions.« less

  17. Working sketch of an anatomically and optically equivalent physical model eye

    NASA Astrophysics Data System (ADS)

    Bakaraju, Ravi Chandra; Ehrmann, Klaus; Falk, Darrin; Papas, Eric B.; Ho, Arthur

    2009-02-01

    Our aim was to fabricate a bench-top physical model eye that closely replicates anatomical and optical properties of the average human eye, and to calibrate and standardize this model to suit normal viewing conditions and subsequently utilize it to understand the optical performance of corrective lens designs; especially multifocal soft contact lenses. Using available normative data on ocular biometrics and Zemax ray-tracing software as a tool, we modeled 25, 45 and 55 year-old average adult human eyes with discrete accommodation levels and pupil sizes. Specifications for the components were established following manufacturing tolerance analyses. The cornea was lathed from an optical material with refractive index of 1.376 @ 589 nm and the crystalline lenses were made of Boston RGP polymers with refractive indices of 1.423 (45 & 55yr) and 1.429 (25yr) @ 589 nm. These two materials served to model the equivalent crystalline lens of the different age-groups. A camera, the acting retina, was hosted on the motor-base having translatory and rotary functions to facilitate the simulation of different states of ametropia and peripheral refraction respectively. We report on the implementation of the first prototype and present some simulations of the optical performance of certain contact lenses with specific levels of ametropia, to demonstrate the potential use of such a physical model eye. On completion of development, calibration and standardization, optical quality assessment and performance predictions of different ophthalmic lenses can be studied in great detail. Optical performance with corrective lenses may be reliably simulated and predicted by customized combined computational and physical models giving insight into the merits and pitfalls of their designs

  18. Naked singularities as particle accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patil, Mandar; Joshi, Pankaj S.

    We investigate here the particle acceleration by naked singularities to arbitrarily high center of mass energies. Recently it has been suggested that black holes could be used as particle accelerators to probe the Planck scale physics. We show that the naked singularities serve the same purpose and probably would do better than their black hole counterparts. We focus on the scenario of a self-similar gravitational collapse starting from a regular initial data, leading to the formation of a globally naked singularity. It is seen that when particles moving along timelike geodesics interact and collide near the Cauchy horizon, the energymore » of collision in the center of mass frame will be arbitrarily high, thus offering a window to Planck scale physics.« less

  19. Full ocular biometry through dual-depth whole-eye optical coherence tomography

    PubMed Central

    Kim, Hyung-Jin; Kim, Minji; Hyeon, Min Gyu; Choi, Youngwoon; Kim, Beop-Min

    2018-01-01

    We propose a new method of determining the optical axis (OA), pupillary axis (PA), and visual axis (VA) of the human eye by using dual-depth whole-eye optical coherence tomography (OCT). These axes, as well as the angles “α” between the OA and VA and “κ” between PA and VA, are important in many ophthalmologic applications, especially in refractive surgery. Whole-eye images are reconstructed based on simultaneously acquired images of the anterior segment and retina. The light from a light source is split into two orthogonal polarization components for imaging the anterior segment and retina, respectively. The OA and PA are identified based on their geometric definitions by using the anterior segment image only, while the VA is detected through accurate correlation between the two images. The feasibility of our approach was tested using a model eye and human subjects. PMID:29552378

  20. Graded-Index Optics are Matched to Optical Geometry in the Superposition Eyes of Scarab Beetles

    NASA Astrophysics Data System (ADS)

    McIntyre, P.; Caveney, S.

    1985-11-01

    Detailed measurements were made of the gradients of refractive index (g.r.i.) and relevant optical properties of the lens components in the ventral superposition eyes of three crepuscular species of the dung-beetle genus Onitis (Scarabaeinae). Each ommatidial lens has two components, a corneal facet and a crystalline cone; in both of these, the gradients provide a significant proportion of the refractive power. The spatial relationship between the lenses and the retina (optical geometry) was also determined. A computer ray-trace model based on these data was used to analyse the optical properties of the lenses and of the eye as a whole. Ray traces were done in two and three dimensions. The ommatidial lenses in all three species are afocal g.r.i. telescopes of low angular magnification. Parallel incident rays emerge approximately parallel for all angles of incidence up to the maximum. The superposition image of a distant point source is a small patch of light about the size of a rhabdom. There are obvious differences in the lens properties of the three species, most significantly in the shape of the refractive-index gradients in the crystalline cone, in the extent of the g.r.i. region in the two lens components and in the front-surface curvature of the corneal facet lens. These give rise to different angular magnifications M of the ommatidial lenses, the values for the three species being 1.7, 1.3, 1.0. This variation in M is matched by a variation in optical geometry, most evident in the different clear-zone widths. As a result, the level of the best superposition image lies close to the retina in the model eyes of all three species. The angular magnification also sets the maximum aperture or pupil of the eye and hence the brightness of the image on the retina. The smaller M, the larger the aperture and the brighter the image. By adopting a suitable value for M and the appropriate eye geometry, an eye can set image brightness and hence sensitivity within a certain

  1. Photorefraction of the Eye

    ERIC Educational Resources Information Center

    Colicchia, Giuseppe; Wiesner, Hartmut; Zollman, Dean

    2015-01-01

    Photorefraction is a method to easily estimate the refractive state of the eye. The principle of photorefraction involves projecting light into the eye during flash photography and then examining the paths of light that emerge from the pupil after scattering on the back portion of the interior of the eyeball (fundus). We will explain the optical…

  2. The research of the style of angel lobster eye x-ray optical system

    NASA Astrophysics Data System (ADS)

    Cheng, HuaQi; Liu, YuJiao; Zhang, ShaoWei; Hou, LinBao; Li, XingLong

    2018-01-01

    This paper has developed the theory research of wide field Angel lobster eye X-ray optical system based on the principle of entirely incidence. Combine the configuration characteristic of lobster eye, recommend the conclusion of beam of light focus on the half of radius whether point or parallel light. Designed the microchannel through the principle of real ray trace and got the relationship among different parameters about it using numerical value emulation. Got pixels and illumination pictures validated the wide field focus characteristic of Angel lobster eye by simulating the optical system.

  3. Optical coherence tomography of the eye

    NASA Astrophysics Data System (ADS)

    Hee, Michael Richard

    1997-10-01

    Optical Coherence Tomography (OCT) is a new technique for high-resolution, cross-sectional imaging of tissue in which the time-of-flight delay of light reflected from internal tissue structures is resolved with high precision using interferometry. Tomographic images are obtained which are analogous to those provided by ultrasound except that image contrast relies on differences in optical rather than acoustic properties of tissue. The use of light rather than sound enables higher resolution (10 μm) and non-contact imaging. A clinically viable high-sensitivity, fiber-optic based OCT instrument has been constructed based on engineering principles derived from optical communication theory. Computer algorithms have also been developed for quantitative image analysis and restoration. OCT has been used to image patients with a variety of ocular diseases. In patients with macular pathology, OCT images have been correlated with conventional clinical examination and fluorescein angiography. Optical coherence tomograms are effective in staging macular holes, evaluating the vitreoretinal interface in eyes at risk for a macular hole, and providing a structural assessment of macular hole surgery. In eyes with central serous chorioretinopathy, OCT can evaluate sensory retinal separations undetected at the slit-lamp. Serial OCT images of macular edema are able to track both the progression of macular thickening and the resolution of macular edema following laser photocoagulation. In patients with diabetic retinopathy, measurements of macular thickness correlate with visual acuity and OCT is more sensitive to small changes in retinal thickness than slit-lamp biomicroscopy. OCT may provide a novel method of defining occult choroidal neovascular membranes in patients with age-related macular degeneration. OCT can also profile the thickness of the retinal nerve fiber layer with high resolution which is potentially important for the objective assessment of early glaucoma progression

  4. [Plastics on the eye - plastics in the eye. Human-optic materials].

    PubMed

    Geyer, Otto-Christian; Schwabe, Peter; Wingler, Frank

    2002-01-01

    Materials of identical or similiar chemical classes are used for contact optics as well as for implantable intraocular devices. All of them derive from the chemistry of industrial product developments. Materials used in and on the eye should behave indifferent. They should not provoke any reaction in the eye and not themselves be altered by the biological surroundings. For materials used in the eye an especially high purity of the polymers utilized as well as a long term light stability is to be demanded. Optical properties like transparency have to be stable over extended time periods under normal light influence. The long time stability of UV-absorbing additives in the materials used has to be verified. All materials used for IOL's - with the exception of the homopolymer of methylmethacrylate - consist of polymer mixtures forming socalled interpenetrating networks which appear as an uniform material. For the manufacturing of intraocular lense materials standardized or unanimous producer prescriptions are not existing. Based on the different polymer formulations different aging and fatigue properties are the outcome. In addition only inadequate knowledge about the long term light stability of the incorporated UV blockers is submitted. Polymeric materials used for IOL's should be subjected in addition to the test methods listed in EN-ISO 11 979/5 to chemical, polymeranalytic and mechanical substance examinations. As a standard in such examinations a polymethylmethacrylate, free of methylacrylate is proposed. Examinations of each lot should be compulsory. Identification of all ingredients of the intraocular materials should be prescribed and labeled in line with the revelations of common medical drugs prescriptions. The relevations commit the medical doctor to inform his patient about possible side effects of the intraocular implants.

  5. Reconstruction of the optical system of personalized eye models by using magnetic resonance imaging.

    PubMed

    Sun, Han-Yin; Lee, Chi-Hung; Chuang, Chun-Chao

    2016-11-10

    This study presents a practical method for reconstructing the optical system of personalized eye models by using magnetic resonance imaging (MRI). Monocular images were obtained from a young (20-year-old) healthy subject viewing at a near point (10 cm). Each magnetic resonance image was first analyzed using several commercial software to capture the profile of each optical element of the human eye except for the anterior lens surface, which could not be determined because it overlapped the ciliary muscle. The missing profile was substituted with a modified profile from a generic eye model. After the data-including the refractive indices from a generic model-were input in ZEMAX, we obtained a reasonable initial layout. By further considering the resolution of the MRI, the model was optimized to match the optical performance of a healthy eye. The main benefit of having a personalized eye model is the ability to quantitatively identify wide-angle ocular aberrations, which were corrected by the designed free-form spectacle lens.

  6. Context-Based Questions: Optics in Animal Eyes

    ERIC Educational Resources Information Center

    Kaltakci, Derya; Eryilmaz, Ali

    2011-01-01

    Context is important as a motivational factor for student involvement with physics. The diversity in the types and the functions of animal eyes is an excellent context in which to achieve this goal. There exists a range of subtopics in optics including pinhole, reflection, refraction, and superposition that can be discussed in the context of the…

  7. A phenolic acid based colourimetric 'naked-eye' chemosensor for the rapid detection of Cu(II) ions

    NASA Astrophysics Data System (ADS)

    Sengupta, Priti; Ganguly, Aniruddha; Bose, Adity

    2018-06-01

    The crucial role of chemosensor for the immediate recognition of environment pollutant motivates the researchers to develop variety of sensing protocols. Of various chemosensory protocols, the colour change observed by the naked eye is considered to be a conceivable and on-site way to indicate the presence of an analyte. We herein report a colourimetric and commercially available absorption probe, sinapic acid (SA) that is completely ready to use for "on-site" visual determination of copper ions. The molecule, SA is well-known phenolic acid, often utilized for its antibacterial activity. In this work, for the first time, we are exploring its ability to work as an efficient Cu2+ sensor. This sensor molecule selectively detected Cu2+ ions by changing its colour from colourless to pink within detection limit of 64.5 nM, which is much lower than other reported sensor molecules and the suggested limit by World Health Organization (WHO) and U. S. Environmental Protection Agency (EPA) guidelines. The sensing mechanism was investigated through UV-vis and 1H NMR titration along with ESI-MS spectroscopy and further confirmed by DFT computational studies. Studies revealed the participation of hydroxyl group (sbnd OH) and methoxy group (sbnd OMe) of SA in complexation with Cu2+. The binding stoichiometry of SA to Cu2+ was found to be 1:2 through Job's plot and ESI-MS analysis. Importantly, paper strips of SA were prepared which could be used for a rapid "on-site" determination of Cu2+ containing samples.

  8. Covalent Binding of Antibodies to Cellulose Paper Discs and Their Applications in Naked-eye Colorimetric Immunoassays.

    PubMed

    Peng, Yanfen; Gelder, Victor Van; Amaladoss, Anburaj; Patel, Kadamb Haribhai

    2016-10-21

    This report presents two methods for the covalent immobilization of capture antibodies on cellulose filter paper grade No. 1 (medium-flow filter paper) discs and grade No. 113 (fast-flow filter paper) discs. These cellulose paper discs were grafted with amine functional groups through a silane coupling technique before the antibodies were immobilized on them. Periodate oxidation and glutaraldehyde cross-linking methods were used to graft capture antibodies on the cellulose paper discs. In order to ensure the maximum binding capacity of the capture antibodies to their targets after immobilization, the effects of various concentrations of sodium periodate, glutaraldehyde, and capture antibodies on the surface of the paper discs were investigated. The antibodies that were coated on the amine-functionalized cellulose paper discs through a glutaraldehyde cross-linking agent showed enhanced binding activity to the target when compared to the periodate oxidation method. IgG (in mouse reference serum) was used as a reference target in this study to test the application of covalently immobilized antibodies through glutaraldehyde. A new paper-based, enzyme-linked immunosorbent assay (ELISA) was successfully developed and validated for the detection of IgG. This method does not require equipment, and it can detect 100 ng/ml of IgG. The fast-flow filter paper was more sensitive than the medium-flow filter paper. The incubation period of this assay was short and required small sample volumes. This naked-eye, colorimetric immunoassay can be extended to detect other targets that are identified with conventional ELISA.

  9. A phenolic acid based colourimetric 'naked-eye' chemosensor for the rapid detection of Cu(II) ions.

    PubMed

    Sengupta, Priti; Ganguly, Aniruddha; Bose, Adity

    2018-06-05

    The crucial role of chemosensor for the immediate recognition of environment pollutant motivates the researchers to develop variety of sensing protocols. Of various chemosensory protocols, the colour change observed by the naked eye is considered to be a conceivable and on-site way to indicate the presence of an analyte. We herein report a colourimetric and commercially available absorption probe, sinapic acid (SA) that is completely ready to use for "on-site" visual determination of copper ions. The molecule, SA is well-known phenolic acid, often utilized for its antibacterial activity. In this work, for the first time, we are exploring its ability to work as an efficient Cu 2+ sensor. This sensor molecule selectively detected Cu 2+ ions by changing its colour from colourless to pink within detection limit of 64.5nM, which is much lower than other reported sensor molecules and the suggested limit by World Health Organization (WHO) and U. S. Environmental Protection Agency (EPA) guidelines. The sensing mechanism was investigated through UV-vis and 1 H NMR titration along with ESI-MS spectroscopy and further confirmed by DFT computational studies. Studies revealed the participation of hydroxyl group (OH) and methoxy group (OMe) of SA in complexation with Cu 2+ . The binding stoichiometry of SA to Cu 2+ was found to be 1:2 through Job's plot and ESI-MS analysis. Importantly, paper strips of SA were prepared which could be used for a rapid "on-site" determination of Cu 2+ containing samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Impact Flash Physics: Modeling and Comparisons With Experimental Results

    NASA Astrophysics Data System (ADS)

    Rainey, E.; Stickle, A. M.; Ernst, C. M.; Schultz, P. H.; Mehta, N. L.; Brown, R. C.; Swaminathan, P. K.; Michaelis, C. H.; Erlandson, R. E.

    2015-12-01

    Hypervelocity impacts frequently generate an observable "flash" of light with two components: a short-duration spike due to emissions from vaporized material, and a long-duration peak due to thermal emissions from expanding hot debris. The intensity and duration of these peaks depend on the impact velocity, angle, and the target and projectile mass and composition. Thus remote sensing measurements of planetary impact flashes have the potential to constrain the properties of impacting meteors and improve our understanding of impact flux and cratering processes. Interpreting impact flash measurements requires a thorough understanding of how flash characteristics correlate with impact conditions. Because planetary-scale impacts cannot be replicated in the laboratory, numerical simulations are needed to provide this insight for the solar system. Computational hydrocodes can produce detailed simulations of the impact process, but they lack the radiation physics required to model the optical flash. The Johns Hopkins University Applied Physics Laboratory (APL) developed a model to calculate the optical signature from the hot debris cloud produced by an impact. While the phenomenology of the optical signature is understood, the details required to accurately model it are complicated by uncertainties in material and optical properties and the simplifications required to numerically model radiation from large-scale impacts. Comparisons with laboratory impact experiments allow us to validate our approach and to draw insight regarding processes that occur at all scales in impact events, such as melt generation. We used Sandia National Lab's CTH shock physics hydrocode along with the optical signature model developed at APL to compare with a series of laboratory experiments conducted at the NASA Ames Vertical Gun Range. The experiments used Pyrex projectiles to impact pumice powder targets with velocities ranging from 1 to 6 km/s at angles of 30 and 90 degrees with respect to

  11. "Staying in Focus"--An Online Optics Tutorial on the Eye

    ERIC Educational Resources Information Center

    Hoeling, Barbara M.

    2011-01-01

    The human eye and its vision problems are often used as an entry subject and attention grabber in the teaching of geometrical optics. While this is a real-life application students can relate to, it is difficult to visualize how the eye forms images by studying the still pictures and drawings in a textbook. How to draw a principal ray diagram or…

  12. Influence of changes in an eye's optical system on refraction

    NASA Astrophysics Data System (ADS)

    Bartkowska, Janina

    1998-10-01

    The optical system of eye is composed of cornea, lens, anterior chamber, and vitreous body. In the standard schematic eye there are 6 refracting surfaces. The changes of the curvature radii, of the distances between them, of the refractive indices influence the ametropia, refractive power of the eye and retinal image size. The influence of these changes can be appreciated by ray tracing or by an analytical method. There are presented simplified formulae for the differentials of ametropia and refractive power of the eye with respect to the surfaces curvatures, refracting power of cornea and lens, refractive indices. The relations are valid too for bigger changes if ametropia is measured in the cornea vertex. The formulae for the differentials with respect to distances, lens translation, eye axis length are valid if ametropia is measured in the object focus of the eye.

  13. 'Naked-eye' detection of biologically important anions in aqueous media by colorimetric receptor and its real life applications

    NASA Astrophysics Data System (ADS)

    Singh, Archana; Trivedi, Darshak R.

    2017-05-01

    A colorimetric receptor R 2-[(2-Hydroxy-naphthalen-1-ylmethylene)-hydrazonomethyl]-quinolin-8-ol has been designed and synthesized with good yield and characterized by the standard spectroscopic techniques such as FT-IR, UV-Visible, 1H NMR, 13C NMR and ESI-MS. The receptor R showed naked-eye detection and spectral change in the presence of F-, AcO- and H2PO4- over other anions. Interestingly, receptor R displaying high selective recognition towards F-, AcO- ion with a drastic color change from pale yellow to red in dry DMSO solvent and orange in mixed solvent DMSO/H2O (9:1, v/v). The behavior of receptor R towards F-, AcO- ion was investigated using UV-Vis and 1H NMR experiment. The detailed 1H NMR experiment result revealed that the receptor R is forming the hydrogen bonding between imine nitrogen and phenolic sbnd OH proton towards anions. The receptor R is able to detect sodium salts of flouride (NaF) and acetate (NaAcO) in aqueous medium and it exhibited dramatic color change from pale yellow to red. The receptor R demonstrated itself to be useful for real life application by detecting flouride and acetate ion in sea-water and commercially available product such as toothpaste, mouthwash and vinegar solution.

  14. FLASH fly-by-light flight control demonstration results overview

    NASA Astrophysics Data System (ADS)

    Halski, Don J.

    1996-10-01

    The Fly-By-Light Advanced Systems Hardware (FLASH) program developed Fly-By-Light (FBL) and Power-By-Wire (PBW) technologies for military and commercial aircraft. FLASH consists of three tasks. Task 1 developed the fiber optic cable, connectors, testers and installation and maintenance procedures. Task 3 developed advanced smart, rotary thin wing and electro-hydrostatic (EHA) actuators. Task 2, which is the subject of this paper,l focused on integration of fiber optic sensors and data buses with cable plant components from Task 1 and actuators from Task 3 into centralized and distributed flight control systems. Both open loop and piloted hardware-in-the-loop demonstrations were conducted with centralized and distributed flight control architectures incorporating the AS-1773A optical bus, active hand controllers, optical sensors, optimal flight control laws in high speed 32-bit processors, and neural networks for EHA monitoring and fault diagnosis. This paper overviews the systems level testing conducted under the FLASH Flight Control task. Preliminary results are summarized. Companion papers provide additional information.

  15. Modeling the focusing efficiency of lobster-eye optics for image shifting depending on the soft x-ray wavelength.

    PubMed

    Su, Luning; Li, Wei; Wu, Mingxuan; Su, Yun; Guo, Chongling; Ruan, Ningjuan; Yang, Bingxin; Yan, Feng

    2017-08-01

    Lobster-eye optics is widely applied to space x-ray detection missions and x-ray security checks for its wide field of view and low weight. This paper presents a theoretical model to obtain spatial distribution of focusing efficiency based on lobster-eye optics in a soft x-ray wavelength. The calculations reveal the competition mechanism of contributions to the focusing efficiency between the geometrical parameters of lobster-eye optics and the reflectivity of the iridium film. In addition, the focusing efficiency image depending on x-ray wavelengths further explains the influence of different geometrical parameters of lobster-eye optics and different soft x-ray wavelengths on focusing efficiency. These results could be beneficial to optimize parameters of lobster-eye optics in order to realize maximum focusing efficiency.

  16. A Theoretical Analysis of a New Polarimetric Optical Scheme for Glucose Sensing in the Human Eye

    NASA Technical Reports Server (NTRS)

    Rovati, Luigi L.; Boeckle, Stefan; Ansari, Rafat R.; Salzman, Jack A. (Technical Monitor)

    2002-01-01

    The challenging task of in vivo polarimetric glucose sensing is the identification and selection of a scheme to optically access the aqueous humor of the human eye. In this short communication an earlier approach of Cote et al. is theoretically compared with our new optical scheme. Simulations of the new scheme using the eye model of Navarro, suggest that the new optical geometry can overcome the limitations of the previous approach for in vivo measurements of glucose in a human eye.

  17. Analytic Perturbation Method for Estimating Ground Flash Fraction from Satellite Lightning Observations

    NASA Technical Reports Server (NTRS)

    Koshak, William; Solakiewicz, Richard

    2013-01-01

    An analytic perturbation method is introduced for estimating the lightning ground flash fraction in a set of N lightning flashes observed by a satellite lightning mapper. The value of N is large, typically in the thousands, and the observations consist of the maximum optical group area produced by each flash. The method is tested using simulated observations that are based on Optical Transient Detector (OTD) and Lightning Imaging Sensor (LIS) data. National Lightning Detection NetworkTM (NLDN) data is used to determine the flash-type (ground or cloud) of the satellite-observed flashes, and provides the ground flash fraction truth for the simulation runs. It is found that the mean ground flash fraction retrieval errors are below 0.04 across the full range 0-1 under certain simulation conditions. In general, it is demonstrated that the retrieval errors depend on many factors (i.e., the number, N, of satellite observations, the magnitude of random and systematic measurement errors, and the number of samples used to form certain climate distributions employed in the model).

  18. Timelike naked singularity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goswami, Rituparno; Joshi, Pankaj S.; Vaz, Cenalo

    We construct a class of spherically symmetric collapse models in which a naked singularity may develop as the end state of collapse. The matter distribution considered has negative radial and tangential pressures, but the weak energy condition is obeyed throughout. The singularity forms at the center of the collapsing cloud and continues to be visible for a finite time. The duration of visibility depends on the nature of energy distribution. Hence the causal structure of the resulting singularity depends on the nature of the mass function chosen for the cloud. We present a general model in which the naked singularitymore » formed is timelike, neither pointlike nor null. Our work represents a step toward clarifying the necessary conditions for the validity of the Cosmic Censorship Conjecture.« less

  19. Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging.

    PubMed

    Corcoran, Anthony; Muyo, Gonzalo; van Hemert, Jano; Gorman, Alistair; Harvey, Andrew R

    2015-12-15

    Optical coherence tomography (OCT) and reflectance imaging are used in clinical practice to measure the thickness and transverse dimensions of retinal features. The recent trend towards increasing the field of view (FOV) of these devices has led to an increasing significance of the optical aberrations of both the human eye and the device. We report the design, manufacture and application of the first phantom eye that reproduces the off-axis optical characteristics of the human eye, and allows the performance assessment of wide-field ophthalmic devices. We base our design and manufacture on the wide-field schematic eye, [Navarro, R. J. Opt. Soc. Am. A , 1985, 2 .] as an accurate proxy to the human eye and enable assessment of ophthalmic imaging performance for a [Formula: see text] external FOV. We used multi-material 3D-printed retinal targets to assess imaging performance of the following ophthalmic instruments: the Optos 200Tx, Heidelberg Spectralis, Zeiss FF4 fundus camera and Optos OCT SLO and use the phantom to provide an insight into some of the challenges of wide-field OCT.

  20. Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging

    NASA Astrophysics Data System (ADS)

    Corcoran, Anthony; Muyo, Gonzalo; van Hemert, Jano; Gorman, Alistair; Harvey, Andrew R.

    2015-12-01

    Optical coherence tomography (OCT) and reflectance imaging are used in clinical practice to measure the thickness and transverse dimensions of retinal features. The recent trend towards increasing the field of view (FOV) of these devices has led to an increasing significance of the optical aberrations of both the human eye and the device. We report the design, manufacture and application of the first phantom eye that reproduces the off-axis optical characteristics of the human eye, and allows the performance assessment of wide-field ophthalmic devices. We base our design and manufacture on the wide-field schematic eye, [Navarro, R. J. Opt. Soc. Am. A, 1985, 2.] as an accurate proxy to the human eye and enable assessment of ophthalmic imaging performance for a ? external FOV. We used multi-material 3D-printed retinal targets to assess imaging performance of the following ophthalmic instruments: the Optos 200Tx, Heidelberg Spectralis, Zeiss FF4 fundus camera and Optos OCT SLO and use the phantom to provide an insight into some of the challenges of wide-field OCT.

  1. Increased Expression of CCN2 in the Red Flashing Light-Induced Myopia in Guinea Pigs

    PubMed Central

    Wang, Hong; Zhuang, Kang; Gao, Lei; Zhang, Linna; Yang, Hongling

    2013-01-01

    Visual environment plays an important role in the occurrence of myopia. We previously showed that the different flashing lights could result in distinct effects on the ocular growth and development of myopia. CCN2 has been reported to regulate various cellular functions and biological processes. However, whether CCN2 signaling was involved in the red flashing light-induced myopia still remains unknown. In the present study, we investigated the effects of the red flashing lights exposure on the refraction and axial length of the eyes in vivo and then evaluated their effects on the expression of CCN2 and TGF-β in sclera tissues. Our data showed that the eyes exposed to the red flashing light became more myopic with a significant increase of the axial length and decrease of the refraction. Both CCN2 and TGF-β, as well as p38 MAPK and PI3K, were highly expressed in the sclera tissues exposed to the red flashing light. Both CCN2 and TGF-β were found to have the same gene expression profile in vivo. In conclusion, our findings found that CCN2 signaling pathway plays an important role in the red flashing light-induced myopia in vivo. Moreover, our study establishes a useful animal model for experimental myopia research. PMID:23936844

  2. Special technical services for investigation of light flash phenomena

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Details are presented of an investigation aimed at an explanation of the phenomenon of light flashes observed by Apollo crew members. The various theories considered include: penetration of the eye by cosmic particles resulting in retinal stimulation; production of phosphenes or sensations of light through ionization or excitation; appearance of heavily ionized single tracks misinterpreted as light flashes; Cerenkov radiation; and direct excitation of neural tissue by penetrating cosmic rays. It is concluded that the latter two theories are the likeliest mechanisms for the development of a definitive explanation.

  3. Lobster eye X-ray optics: Data processing from two 1D modules

    NASA Astrophysics Data System (ADS)

    Nentvich, O.; Urban, M.; Stehlikova, V.; Sieger, L.; Hudec, R.

    2017-07-01

    The X-ray imaging is usually done by Wolter I telescopes. They are suitable for imaging of a small part of the sky, not for all-sky monitoring. This monitoring could be done by a Lobster eye optics which can theoretically have a field of view up to 360 deg. All sky monitoring system enables a quick identification of source and its direction. This paper describes the possibility of using two independent one-dimensional Lobster Eye modules for this purpose instead of Wolter I and their post-processing into an 2D image. This arrangement allows scanning with less energy loss compared to Wolter I or two-dimensional Lobster Eye optics. It is most suitable especially for very weak sources.

  4. Visual optics and ecomorphology of the growing shark eye: a comparison between deep and shallow water species.

    PubMed

    Litherland, Lenore; Collin, Shaun P; Fritsches, Kerstin A

    2009-11-01

    Elasmobranch fishes utilise their vision as an important source of sensory information, and a range of visual adaptations have been shown to reflect the ecological diversity of this vertebrate group. This study investigates the hypotheses that visual optics can predict differences in habitat and behaviour and that visual optics change with ontogenetic growth of the eye to maintain optical performance. The study examines eye structure, pupillary movement, transmission properties of the ocular media, focal properties of the lens, tapetum structure and variations in optical performance with ontogenetic growth in two elasmobranch species: the carcharhinid sandbar shark, Carcharhinus plumbeus, inhabiting nearshore coastal waters, and the squalid shortspine spurdog, Squalus mitsukurii, inhabiting deeper waters of the continental shelf and slope. The optical properties appear to be well tuned for the visual needs of each species. Eyes continue to grow throughout life, resulting in an ontogenetic shift in the focal ratio of the eye. The eyes of C. plumbeus are optimised for vision under variable light conditions, which change during development as the animal probes new light environments in its search for food and mates. By contrast, the eyes of S. mitsukurii are specifically adapted to enhance retinal illumination within a dim light environment, and the detection of bioluminescent prey may be optimised with the use of lenticular short-wavelength-absorbing filters. Our findings suggest that the light environment strongly influences optical features in this class of vertebrates and that optical properties of the eye may be useful predictors of habitat and behaviour for lesser-known species of this vertebrate group.

  5. Effect of the internal optics on the outcome of custom-LASIK in an eye model

    NASA Astrophysics Data System (ADS)

    Manns, Fabrice; Ho, Arthur; Parel, Jean-Marie

    2004-07-01

    Purpose. The purpose of this study was to evaluate if changes in the aberration-contribution of the internal optics of the eye have a significant effect on the outcome of wavefront-guided corneal reshaping. Methods. The Navarro-Escudero eye model was simulated using optical analysis software. The eye was rendered myopic by shifting the plane of the retina. Custom-LASIK was simulated by changing the radius of curvature and asphericity of the anterior corneal surface of the eye model. The radius of curvature was adjusted to provide a retinal conjugate at infinity. Three approaches were used to determine the postoperative corneal asphericity: minimizing third-order spherical aberration, minimizing third-order coma, and maximizing the Strehl ratio. The aberration contribution of the anterior corneal surface and internal optics was calculated before and after each simulated customized correction. Results. For a 5.2mm diameter pupil, the contribution of the anterior corneal surface to third-order spherical aberration and coma (in micrometers) was 2.22 and 2.49 preop, -0.36 and 2.83 postop when spherical aberration is minimized, 5.88 and 1.10 postop when coma is minimized, and -0.63 and 2.91 postop when Strehl ratio is maximized. The contribution of the internal optics of the eye to spherical aberration and coma for the same four conditions was: 0.43 and -1.13, 0.37 and -1.10, 0.37 and -1.10 and 0.37 and -1.10, respectively. Conclusion. In the model eye, the contribution of the internal optics of the eye to the change in the ocular aberration state is negligible.

  6. A Grobner Basis Solution for Lightning Ground Flash Fraction Retrieval

    NASA Technical Reports Server (NTRS)

    Solakiewicz, Richard; Attele, Rohan; Koshak, William

    2011-01-01

    A Bayesian inversion method was previously introduced for retrieving the fraction of ground flashes in a set of flashes observed from a (low earth orbiting or geostationary) satellite lightning imager. The method employed a constrained mixed exponential distribution model to describe the lightning optical measurements. To obtain the optimum model parameters, a scalar function was minimized by a numerical method. In order to improve this optimization, we introduce a Grobner basis solution to obtain analytic representations of the model parameters that serve as a refined initialization scheme to the numerical optimization. Using the Grobner basis, we show that there are exactly 2 solutions involving the first 3 moments of the (exponentially distributed) data. When the mean of the ground flash optical characteristic (e.g., such as the Maximum Group Area, MGA) is larger than that for cloud flashes, then a unique solution can be obtained.

  7. Functional delivery of synthetic naked siRNA to the human trabecular meshwork in perfused organ cultures.

    PubMed

    Comes, Nuria; Borrás, Teresa

    2007-08-01

    To investigate whether naked short-interfering RNA (siRNA) molecules could be directly delivered to perfused intact human trabecular meshwork (TM) tissue, whether this siRNA could silence a trabecular meshwork preferred gene, and whether it could counteract the downstream effect of a deleterious agent (dexamethasone, DEX) by silencing its receptor. Anterior segments from post-mortem normal human donors were perfused at 3.4+/-0.3 microl/min-constant flow or 15 mmHg-constant pressure to stable baseline (outflow facility, C=0.22+/-0.19 microl/min/mmHg; n=14). Commercial siRNAs were diluted in DMEM (Dulbecco's Modified Eagle's Medium) perfusion medium and used without coupling to transfection reagents ("naked"). Perfusion of Cy3-labeled siRNA was performed at 100 nM for 48 h followed by 24 h with DMEM medium (two pairs). Perfusions of Matrix GLA protein (MGP) siRNA (100 nM; right eye [Oculus Dexter]; OD) and scramble-siRNA (control; left eye [Oculus Sinster]; OS) were performed for 48 h (two pairs). Perfusions of glucocorticoid receptor (GR)-siRNA (OD) and scramble-control (OS) were performed for 48 h and continued by adding 100 nM DEX to the perfusion media for an additional 24 h (two pairs). Frozen sections of labeled anterior segments were analyzed by confocal fluorescence microscopy. Differential expression of GR, MGP, myocilin (MYOC), cornea-derived transcript 6 (CDT6), and 18S genes was determined by reverse-transcriptase TaqMan polymerase chain reacion (RT-TaqMan PCR) on RNA extracted from dissected trabecular meshwork. Primary human trabecular meshwork cells were generated from single individuals and transfected using the nucleofector electroporator with program T-23. Levels of secreted MYOC in the effluents were analyzed by western blot. Histological evaluation of anterior segments perfused with Cy3 labeled siRNA followed by unlabeled medium showed intense fluorescence in the trabecular meshwork region. MGP gene expression was silenced in the trabecular

  8. Can accretion disk properties observationally distinguish black holes from naked singularities?

    NASA Astrophysics Data System (ADS)

    Kovács, Z.; Harko, T.

    2010-12-01

    Naked singularities are hypothetical astrophysical objects, characterized by a gravitational singularity without an event horizon. Penrose has proposed a conjecture, according to which there exists a cosmic censor who forbids the occurrence of naked singularities. Distinguishing between astrophysical black holes and naked singularities is a major challenge for present day observational astronomy. In the context of stationary and axially symmetrical geometries, a possibility of differentiating naked singularities from black holes is through the comparative study of thin accretion disks properties around rotating naked singularities and Kerr-type black holes, respectively. In the present paper, we consider accretion disks around axially-symmetric rotating naked singularities, obtained as solutions of the field equations in the Einstein-massless scalar field theory. A first major difference between rotating naked singularities and Kerr black holes is in the frame dragging effect, the angular velocity of a rotating naked singularity being inversely proportional to its spin parameter. Because of the differences in the exterior geometry, the thermodynamic and electromagnetic properties of the disks (energy flux, temperature distribution and equilibrium radiation spectrum) are different for these two classes of compact objects, consequently giving clear observational signatures that could discriminate between black holes and naked singularities. For specific values of the spin parameter and of the scalar charge, the energy flux from the disk around a rotating naked singularity can exceed by several orders of magnitude the flux from the disk of a Kerr black hole. In addition to this, it is also shown that the conversion efficiency of the accreting mass into radiation by rotating naked singularities is always higher than the conversion efficiency for black holes, i.e., naked singularities provide a much more efficient mechanism for converting mass into radiation than black

  9. Mismatch between the eye and the optic lobe in the giant squid.

    PubMed

    Liu, Yung-Chieh; Liu, Tsung-Han; Yu, Chun-Chieh; Su, Chia-Hao; Chiao, Chuan-Chin

    2017-07-01

    Giant squids ( Architeuthis ) are a legendary species among the cephalopods. They live in the deep sea and are well known for their enormous body and giant eyes. It has been suggested that their giant eyes are not adapted for the detection of either mates or prey at distance, but rather are best suited for monitoring very large predators, such as sperm whales, at distances exceeding 120 m and at a depth below 600 m (Nilsson et al. 2012 Curr. Biol. 22 , 683-688. (doi:10.1016/j.cub.2012.02.031)). However, it is not clear how the brain of giant squids processes visual information. In this study, the optic lobe of a giant squid ( Architeuthis dux , male, mantle length 89 cm), which was caught by local fishermen off the northeastern coast of Taiwan, was scanned using high-resolution magnetic resonance imaging in order to examine its internal structure. It was evident that the volume ratio of the optic lobe to the eye in the giant squid is much smaller than that in the oval squid ( Sepioteuthis lessoniana ) and the cuttlefish ( Sepia pharaonis ). Furthermore, the cell density in the cortex of the optic lobe is significantly higher in the giant squid than in oval squids and cuttlefish, with the relative thickness of the cortex being much larger in Architeuthis optic lobe than in cuttlefish. This indicates that the relative size of the medulla of the optic lobe in the giant squid is disproportionally smaller compared with these two cephalopod species. This morphological study of the giant squid brain, though limited only to the optic lobe, provides the first evidence to support that the optic lobe cortex, the visual information processing area in cephalopods, is well developed in the giant squid. In comparison, the optic lobe medulla, the visuomotor integration centre in cephalopods, is much less developed in the giant squid than other species. This finding suggests that, despite the giant eye and a full-fledged cortex within the optic lobe, the brain of giant

  10. Optic neuropathy in thyroid eye disease: results of the balanced decompression technique.

    PubMed

    Baril, Catherine; Pouliot, Denis; Molgat, Yvonne

    2014-04-01

    To determine the efficacy of combined endoscopic medial and external lateral orbital decompression for the treatment of compressive optic neuropathy (CON) in thyroid eye disease (TED). A retrospective review of all patients undergoing combined surgical orbital decompression for CON between 2000 and 2010 was conducted. Fifty-nine eyes of 34 patients undergoing combined surgical orbital decompression for CON. Clinical outcome measures included visual acuity, Hardy-Rand-Rittler (HRR) colour plate testing, relative afferent pupillary defect, intraocular pressure measurement, and Hertel exophthalmometry. A CON score was calculated preoperatively and postoperatively based on the visual acuity and the missed HRR plates. A higher CON score correlates with more severe visual dysfunction. All patients had improvement of their optic neuropathy after surgical decompression. CON score was calculated for 54 eyes and decreased significantly from a mean of 13.2 ± 10.35 preoperatively to a mean of 8.51 ± 10.24 postoperatively (p < 0.0001). Optic neuropathy was completely resolved in 93.22% (55/59 eyes). Eighteen of 34 patients (52.94%) experienced development of new-onset postoperative strabismus that required subsequent surgical intervention. Endoscopic medial combined with external lateral orbital decompression is an effective technique for the treatment of TED-associated CON. © 2013 Canadian Ophthalmological Society Published by Canadian Ophthalmological Society All rights reserved.

  11. Measurement and standardization of eye safety for optical radiation of LED products

    NASA Astrophysics Data System (ADS)

    Mou, Tongsheng; Peng, Zhenjian

    2013-06-01

    The blue light hazard (BLH) to human eye's retina is now a new issue emerging in applications of artificial light sources. Especially for solid state lighting sources based on the blue chip-LED(GaN), the photons with their energy more than 2.4 eV show photochemical effects on the retina significantly, raising damage both in photoreceptors and retinal pigment epithelium. The photobiological safety of artificial light sources emitting optical radiation has gained more and more attention worldwide and addressed by international standards IEC 62471-2006(CIE S009/E: 2002). Meanwhile, it is involved in IEC safety specifications of LED lighting products and covered by European Directive 2006/25/EC on the minimum health and safety requirements regarding the exposure of the workers to artificial optical radiation. In practical applications of the safety standards, the measuring methods of optical radiation from LED products to eyes are important in establishment of executable methods in the industry. In 2011, a new project to develop the international standard of IEC TR62471-4,that is "Measuring methods of optical radiation related to photobiological safety", was approved and are now under way. This paper presents the concerned methods for the assessment of optical radiation hazards in the standards. Furthermore, a retina radiance meter simulating eye's optical geometry is also described, which is a potential tool for blue light hazard assessment of retinal exposure to optical radiation. The spectroradiometric method integrated with charge-coupled device(CCD) imaging system is introduced to provide more reliable results.

  12. Fish eye optics

    NASA Astrophysics Data System (ADS)

    Hudec, R.; Michalova, S.

    2017-07-01

    We report on small student (high—school) project of the Czech Academy of Sciences dealing with animal (fish) eyes and possible application in science and technology. Albeit most fishes have refractive eyes, the recent discoveries confirm that some fishes have reflective eyes with strange arrangements as well.

  13. Highly sensitive on-site detection of glucose in human urine with naked eye based on enzymatic-like reaction mediated etching of gold nanorods.

    PubMed

    Zhang, Zhiyang; Chen, Zhaopeng; Cheng, Fangbin; Zhang, Yaowen; Chen, Lingxin

    2017-03-15

    Based on enzymatic-like reaction mediated etching of gold nanorods (GNRs), an ultrasensitive visual method was developed for on-site detection of urine glucose. With the catalysis of MoO 4 2 - , GNRs were efficiently etched by H 2 O 2 which was generated by glucose-glucose oxidase enzymatic reaction. The etching of GNRs lead to a blue-shift of logitudinal localized surface plasmon resonance of GNRs, accompanied by an obvious color change from blue to red. The peak-shift and the color change can be used for detection of glucose by the spectrophotometer and the naked eyes. Under optimal condition, an excellent sensitivity toward glucose is obtained with a detection limit of 0.1μM and a visual detection limit of 3μM in buffer solution. Benefiting from the high sensitivity, the successful colorimetric detection of glucose in original urine samples was achieved, which indicates the practical applicability to the on-site determination of urine glucose. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Effect of the incidence angle to free space optical communication based on cat-eye modulating retro-reflector

    NASA Astrophysics Data System (ADS)

    Zhang, Lai-xian; Sun, Hua-yan; Zhao, Yan-zhong; Zheng, Yong-hui; Shan, Cong-miao

    2013-08-01

    Based on the cat-eye effect of optical system, free space optical communication based on cat-eye modulating retro-reflector can build communication link rapidly. Compared to classical free space optical communication system, system based on cat-eye modulating retro-reflector has great advantages such as building communication link more rapidly, a passive terminal is smaller, lighter and lower power consuming. The incident angle is an important factor of cat-eye effect, so it will affect the retro-reflecting communication link. In this paper, the principle and work flow of free space optical communication based on cat-eye modulating retro-reflector were introduced. Then, using the theory of geometric optics, the equivalent model of modulating retro-reflector with incidence angle was presented. The analytical solution of active area and retro-reflected light intensity of cat-eye modulating retro-reflector were given. Noise of PIN photodetector was analyzed, based on which, bit error rate of free space optical communication based on cat-eye modulating retro-reflector was presented. Finally, simulations were done to study the effect of incidence angle to the communication. The simulation results show that the incidence angle has little effect on active area and retro-reflected light intensity when the incidence beam is in the active field angle of cat-eye modulating retro-reflector. With certain system and condition, the communication link can rapidly be built when the incidence light beam is in the field angle, and the bit error rate increases greatly with link range. When link range is smaller than 35Km, the bit error rate is less than 10-16.

  15. A circadian rhythm in optic nerve impulses from an isolated eye in darkness.

    NASA Technical Reports Server (NTRS)

    Jacklet, J. W.

    1971-01-01

    Study of the circadian rhythm of optic nerve potentials recorded from the isolated eye of the sea hare Aplysia. The optic nerve activity in constant conditions is found to be clearly circadian and to obey the circadian rule for diurnal animals. In addition, the period length depends on the in vitro culturing solution. In seawater it is about 22 hr, but in culture medium it is 27 hr. The rhythm can be completely phase-shifted in one trial if the phase of the LD 12:12 Zeitgeber is advanced or delayed 4 hr. The rhythm in one eye can be phase-shifted in vivo independently of the other eye and in vitro independently of the rest of the animal. Thus, in the animal, the eye oscillators are, at most, only slightly influenced by each other or by other oscillators in the animal.

  16. The Classification Ability with Naked Eyes According to the Understanding Level about Rocks of Pre-service Science Teachers

    NASA Astrophysics Data System (ADS)

    Seong, Cho Kyu; Ho, Chung Duk; Pyo, Hong Deok; Kyeong Jin, Park

    2016-04-01

    This study aimed to investigate the classification ability with naked eyes according to the understanding level about rocks of pre-service science teachers. We developed a questionnaire concerning misconception about minerals and rocks. The participant were 132 pre-service science teachers. Data were analyzed using Rasch model. Participants were divided into a master group and a novice group according to their understanding level. Seventeen rocks samples (6 igneous, 5 sedimentary, and 6 metamorphic rocks) were presented to pre-service science teachers to examine their classification ability, and they classified the rocks according to the criteria we provided. The study revealed three major findings. First, the pre-service science teachers mainly classified rocks according to textures, color, and grain size. Second, while they relatively easily classified igneous rocks, participants were confused when distinguishing sedimentary and metamorphic rocks from one another by using the same classification criteria. On the other hand, the understanding level of rocks has shown a statistically significant correlation with the classification ability in terms of the formation mechanism of rocks, whereas there was no statically significant relationship found with determination of correct name of rocks. However, this study found that there was a statistically significant relationship between the classification ability with regard the formation mechanism of rocks and the determination of correct name of rocks Keywords : Pre-service science teacher, Understanding level, Rock classification ability, Formation mechanism, Criterion of classification

  17. How Else Can We Detect Fast Radio Bursts?

    NASA Astrophysics Data System (ADS)

    Lyutikov, Maxim; Lorimer, Duncan R.

    2016-06-01

    We discuss possible electromagnetic signals accompanying Fast Radio Bursts (FRBs) that are expected in the scenario where FRBs originate in neutron star magnetospheres. For models involving Crab-like giant pulses, no appreciable contemporaneous emission is expected at other wavelengths. However, magnetar giant flares, driven by the reconfiguration of the magnetosphere, can produce both contemporaneous bursts at other wavelengths as well as afterglow-like emission. We conclude that the best chances are: (I) prompt short GRB-like emission, (II) a contemporaneous optical flash that can reach naked eye peak luminosity (but only for a few milliseconds), and (III) a high-energy afterglow emission. Case (I) could be tested by coordinated radio and high-energy experiments. Case (II) could be seen in a coordinated radio-optical surveys, e.g., by the Palomar Transient Factory in a 60 s frame as a transient object of m = 15-20 mag with an expected optical detection rate of about 0.1 hr-1, an order of magnitude higher than in radio. Shallow, but large-area sky surveys such as ASAS-SN and EVRYSCOPE could also detect prompt optical flashes from the more powerful Lorimer-burst clones. The best constraints on the optical to radio power for this kind of emission could be provided by future observations with facilities like Large Synoptic Survey Telescope. Case (III) might be seen in relatively rare cases that the relativistically ejected magnetic blob is moving along the line of sight.

  18. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study.

    PubMed

    Barsingerhorn, A D; Boonstra, F N; Goossens, H H L M

    2017-02-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different stereo eye-tracking methods. We found that pupil size, gaze direction and head position all influence the reconstruction of gaze. Resulting errors range between ± 1.0 degrees at best. This shows that stereo eye-tracking may be an option if reliable calibration is not possible, but the applied eye-model should account for the actual optics of the cornea.

  19. Naked singularities in higher dimensional Vaidya space-times

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghosh, S. G.; Dadhich, Naresh

    We investigate the end state of the gravitational collapse of a null fluid in higher-dimensional space-times. Both naked singularities and black holes are shown to be developing as the final outcome of the collapse. The naked singularity spectrum in a collapsing Vaidya region (4D) gets covered with the increase in dimensions and hence higher dimensions favor a black hole in comparison to a naked singularity. The cosmic censorship conjecture will be fully respected for a space of infinite dimension.

  20. Towards femtosecond laser surgery guidance in the posterior eye: utilization of optical coherence tomography and adaptive optics for focus positioning and shaping

    NASA Astrophysics Data System (ADS)

    Krüger, Alexander; Hansen, Anja; Matthias, Ben; Ripken, Tammo

    2014-02-01

    Although fs-laser surgery is clinically established in the field of corneal flap cutting for laser in situ keratomileusis, surgery with fs-laser in the posterior part of the eye is impaired by focus degradation due to aberrations. Precise targeting and keeping of safety distance to the retina also relies on an intraoperative depth resolved imaging. We demonstrate a concept for image guided fs-laser surgery in the vitreous body combining adaptive optics (AO) for focus reshaping and optical coherence tomography (OCT) for focus position guidance. The setup of the laboratory system consist of an 800 nm fs-laser which is focused into a simple eye model via a closed loop adaptive optics system with Hartmann-Shack sensor and a deformable mirror to correct for wavefront aberrations. A spectral domain optical coherence tomography system is used to target phantom structures in the eye model. Both systems are set up to share the same scanner and focusing optics. The use of adaptive optics results in a lowered threshold energy for laser induced breakdown and an increased cutting precision. 3D OCT imaging of porcine retinal tissue prior and immediately after fs-laser cutting is also demonstrated. In the near future OCT and AO will be two essential assistive components in possible clinical systems for fs-laser based eye surgery beyond the cornea.

  1. Light flash phenomena induced by HzE particles

    NASA Technical Reports Server (NTRS)

    Mcnulty, P. J.; Pease, V. P.

    1980-01-01

    Astronauts and Apollo and Skylab missions have reported observing a variety of visual phenomena when their eyes are closed and adapted to darkness. These phenomena have been collectively labelled as light flashes. Visual phenomena which are similar in appearance to those observed in space have been demonstrated at the number of accelerator facilities by expressing the eyes of human subjects to beams of various types of radiation. In some laboratory experiments Cerenkov radiation was found to be the basis for the flashes observed while in other experiments Cerenkov radiation could apparently be ruled out. Experiments that differentiate between Cerenkov radiation and other possible mechanisms for inducing visual phenomena was then compared. The phenomena obtained in the presence and absence of Cerenkov radiation were designed and conducted. A new mechanism proposed to explain the visual phenomena observed by Skylab astronauts as they passed through the South Atlantic Anomaly, namely nuclear interactions in and near the sensitive layer of the retina, is covered. Also some studies to search for similar transient effects of space radiation on sensors and microcomputer memories are described.

  2. Paired-pulse flash-visual evoked potentials: new methods revive an old test.

    PubMed

    Cantello, Roberto; Strigaro, Gionata; Prandi, Paolo; Varrasi, Claudia; Mula, Marco; Monaco, Francesco

    2011-08-01

    We aimed at reviving with modern technology the paired flash-visual evoked potential (F-VEP) testing of the visual system excitability. In the 1960s, methodological problems hindered this test, which was expected to provide important physiologic information. We studied 22 consenting healthy subjects (10 men). We recorded F-VEPs from electrodes over occipital and central brain regions. We delivered single flashes, mixed at random to flash pairs at the interstimulus interval (ISI) of 333, 125, 62.5, 50, 33, and 16.5 ms, (i.e. an internal frequency (IF) of 3, 8, 16, 20, 30, and 60 Hz). Recordings were performed with the subject's eyes closed and opened. The F-VEP was split into a "main complex" and an "afterdischarge", which we analyzed statistically in relation to the eye state (closed or open) and to the changes due to paired stimulation. The eye state affected the single F-VEP size, latency and shape significantly (p<0.05). On paired stimulation, the test (second) F-VEP exhibited significant (p<0.05), ISI-dependent size changes, such as a progressive decrease for ISIs from 62.5 to 16.5 ms (IFs of 16-60 Hz), whose timing/amount varied significantly (p<0.05) according to the eye state and to the F-VEP epoch considered. Suppression of the test F-VEP was never complete, even for the shortest ISI (ISI=16.5 ms, IF=60 Hz). The eye state (closed or open) must be considered meticulously when studying F-VEPs. F-VEP changes on paired stimulation express neural inhibition within the visual system, which can be depicted as ISI-dependent curves. Modern equipment and simplified measures render this an easy test, with statistical validity, providing specific information on the excitability properties of the visual system. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy

    PubMed Central

    Hunter, Jennifer J.; Masella, Benjamin; Dubra, Alfredo; Sharma, Robin; Yin, Lu; Merigan, William H.; Palczewska, Grazyna; Palczewski, Krzysztof; Williams, David R.

    2011-01-01

    In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images of the macaque cone mosaic were obtained using a fluorescence adaptive optics scanning laser ophthalmoscope, overcoming the challenges of a low numerical aperture, imperfect optics of the eye, high required light levels, and eye motion. Although the specific fluorophores are as yet unknown, strong in vivo intrinsic fluorescence allowed images of the cone mosaic. Imaging intact ex vivo retina revealed that the strongest two-photon excited fluorescence signal comes from the cone inner segments. The fluorescence response increased following light stimulation, which could provide a functional measure of the effects of light on photoreceptors. PMID:21326644

  4. Experimental Test of Spatial Updating Models for Monkey Eye-Head Gaze Shifts

    PubMed Central

    Van Grootel, Tom J.; Van der Willigen, Robert F.; Van Opstal, A. John

    2012-01-01

    How the brain maintains an accurate and stable representation of visual target locations despite the occurrence of saccadic gaze shifts is a classical problem in oculomotor research. Here we test and dissociate the predictions of different conceptual models for head-unrestrained gaze-localization behavior of macaque monkeys. We adopted the double-step paradigm with rapid eye-head gaze shifts to measure localization accuracy in response to flashed visual stimuli in darkness. We presented the second target flash either before (static), or during (dynamic) the first gaze displacement. In the dynamic case the brief visual flash induced a small retinal streak of up to about 20 deg at an unpredictable moment and retinal location during the eye-head gaze shift, which provides serious challenges for the gaze-control system. However, for both stimulus conditions, monkeys localized the flashed targets with accurate gaze shifts, which rules out several models of visuomotor control. First, these findings exclude the possibility that gaze-shift programming relies on retinal inputs only. Instead, they support the notion that accurate eye-head motor feedback updates the gaze-saccade coordinates. Second, in dynamic trials the visuomotor system cannot rely on the coordinates of the planned first eye-head saccade either, which rules out remapping on the basis of a predictive corollary gaze-displacement signal. Finally, because gaze-related head movements were also goal-directed, requiring continuous access to eye-in-head position, we propose that our results best support a dynamic feedback scheme for spatial updating in which visuomotor control incorporates accurate signals about instantaneous eye- and head positions rather than relative eye- and head displacements. PMID:23118883

  5. DETECTION OF MICROVASCULAR CHANGES IN EYES OF PATIENTS WITH DIABETES BUT NOT CLINICAL DIABETIC RETINOPATHY USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    PubMed

    de Carlo, Talisa E; Chin, Adam T; Bonini Filho, Marco A; Adhi, Mehreen; Branchini, Lauren; Salz, David A; Baumal, Caroline R; Crawford, Courtney; Reichel, Elias; Witkin, Andre J; Duker, Jay S; Waheed, Nadia K

    2015-11-01

    To evaluate the ability of optical coherence tomography angiography to detect early microvascular changes in eyes of diabetic individuals without clinical retinopathy. Prospective observational study of 61 eyes of 39 patients with diabetes mellitus and 28 control eyes of 22 age-matched healthy subjects that received imaging using optical coherence tomography angiography between August 2014 and March 2015. Eyes with concomitant retinal, optic nerve, and vitreoretinal interface diseases and/or poor-quality images were excluded. Foveal avascular zone size and irregularity, vessel beading and tortuosity, capillary nonperfusion, and microaneurysm were evaluated. Foveal avascular zone size measured 0.348 mm² (0.1085-0.671) in diabetic eyes and 0.288 mm² (0.07-0.434) in control eyes (P = 0.04). Foveal avascular zone remodeling was seen more often in diabetic than control eyes (36% and 11%, respectively; P = 0.01). Capillary nonperfusion was noted in 21% of diabetic eyes and 4% of control eyes (P = 0.03). Microaneurysms and venous beading were noted in less than 10% of both diabetic and control eyes. Both diabetic and healthy control eyes demonstrated tortuous vessels in 21% and 25% of eyes, respectively. Optical coherence tomography angiography was able to image foveal microvascular changes that were not detected by clinical examination in diabetic eyes. Changes to the foveal avascular zone and capillary nonperfusion were more prevalent in diabetic eyes, whereas vessel tortuosity was observed with a similar frequency in normal and diabetic eyes. Optical coherence tomography angiography may be able to detect diabetic eyes at risk of developing retinopathy and to screen for diabetes quickly and noninvasively before the systemic diagnosis is made.

  6. Structural changes of macula and optic disk of the fellow eye in patients with nonarteritic anterior ischemic optic neuropathy.

    PubMed

    Duman, R; Yavas, G F; Veliyev, I; Dogan, M; Duman, R

    2018-05-10

    The aim was to assess the ganglion cell complex (GCC) thickness, retinal nerve fiber layer (RNFL) thickness and optic disk features in the affected eyes (AE) and unaffected fellow eyes (FE) of subjects with unilateral nonarteritic anterior ischemic optic neuropathy (NAION) and to compare with healthy control eyes (CE) using spectral domain-optical coherence tomography (SD-OCT). This study included 28 patients and age, sex and refraction-matched 28 control subjects. Mean GCC thickness and peripapillary RNFL thickness in four quadrants measured by cirrus SD-OCT were evaluated in both AE and FE of patients and CE. In addition, optic disk measurements obtained with OCT were evaluated. Mean GCC thickness was significantly lower in AE compared with both FE and CE (P < 0.001), and mean GCC thickness in FE was significantly lower than CE (P = 0.022). In addition, mean RNFL thickness in superior and nasal quadrants significantly decreased in FE compared with CE (P = 0.020 and 0.010, respectively). Furthermore, AE had significantly greater optic disk cupping compared with both FE and CE (P < 0.001). GCC and RNFL thickness decreased significantly at late stages of NAION, in both AE and FE compared with CE, suggesting that some subclinical structural changes may occur in FE despite lack of obvious visual symptoms. In addition, there was no significant difference in optic disk features between the CE and FE. And significantly greater optic disk cupping in the AE compared with both FE and CE supports the acquired enlargement of cupping after the onset of NAION.

  7. Human Stereopsis is not Limited by the Optics of the Well-focused Eye

    PubMed Central

    Vlaskamp, Björn N.S.; Yoon, Geunyoung; Banks, Martin S.

    2011-01-01

    Human stereopsis—the perception of depth from differences in the two eyes’ images—is very precise: Image differences smaller than a single photoreceptor can be converted into a perceived difference in depth. To better understand what determines this precision, we examined how the eyes’ optics affects stereo resolution. We did this by comparing performance with normal, well-focused optics and with optics improved by eliminating chromatic aberration and correcting higher-order aberrations. We first measured luminance contrast sensitivity in both eyes and showed that we had indeed improved optical quality significantly. We then measured stereo resolution in two ways: by finding the finest corrugation in depth that one can perceive, and by finding the smallest disparity one can perceive as different from zero. Our optical manipulation had no effect on stereo performance. We checked this by redoing the experiments at low contrast and again found no effect of improving optical quality. Thus, the resolution of human stereopsis is not limited by the optics of the well-focused eye. We discuss the implications of this remarkable finding. PMID:21734272

  8. Remote artificial eyes using micro-optical circuit for long-distance 3D imaging perception.

    PubMed

    Thammawongsa, Nopparat; Yupapin, Preecha P

    2016-01-01

    A small-scale optical device incorporated with an optical nano-antenna is designed to operate as the remote artificial eye using a tiny conjugate mirror. A basic device known as a conjugate mirror can be formed using the artificial eye device, the partially reflected light intensities from input source are interfered and the 3D whispering gallery modes formed within the ring centers, which can be modulated and propagated to the object. The image pixel is obtained at the center ring and linked with the optic nerve in the remote area via the nano-antenna, which is useful for blind people.

  9. Design of an ultra-thin near-eye display with geometrical waveguide and freeform optics

    NASA Astrophysics Data System (ADS)

    Tsai, Meng-Che; Lee, Tsung-Xian

    2017-02-01

    Due to the worldwide portable devices and illumination technology trends, researches interest in laser diodes applications are booming in recent years. One of the popular and potential LDs applications is near-eye display used in VR/AR. An ideal near-eye display needs to provide high resolution, wide FOV imagery with compact magnifying optics, and long battery life for prolonged use. However, previous studies still cannot reach high light utilization efficiency in illumination and imaging optical systems which should be raised as possible to increase wear comfort. To meet these needs, a waveguide illumination system of near-eye display is presented in this paper. We focused on proposing a high efficiency RGB LDs light engine which could reduce power consumption and increase flexibility of mechanism design by using freeform TIR reflectors instead of beam splitters. By these structures, the total system efficiency of near-eye display is successfully increased, and the improved results in efficiency and fabrication tolerance of near-eye displays are shown in this paper.

  10. NELIOTA: First temperature measurement of lunar impact flashes

    NASA Astrophysics Data System (ADS)

    Bonanos, A. Z.; Avdellidou, C.; Liakos, A.; Xilouris, E. M.; Dapergolas, A.; Koschny, D.; Bellas-Velidis, I.; Boumis, P.; Charmandaris, V.; Fytsilis, A.; Maroussis, A.

    2018-04-01

    We report the first scientific results from the NELIOTA (NEO Lunar Impacts and Optical TrAnsients) project, which has recently begun lunar monitoring observations with the 1.2-m Kryoneri telescope. NELIOTA aims to detect faint impact flashes produced by near-Earth meteoroids and asteroids and thereby help constrain the size-frequency distribution of near-Earth objects in the decimeter to meter range. The NELIOTA setup, consisting of two fast-frame cameras observing simultaneously in the R and I bands, enables - for the first time - direct analytical calculation of the flash temperatures. We present the first ten flashes detected, for which we find temperatures in the range 1600 to 3100 K, in agreement with theoretical values. Two of these flashes were detected on multiple frames in both filters and therefore yield the first measurements of the temperature drop for lunar flashes. In addition, we compute the impactor masses, which range between 100 g and 50 kg.

  11. Enhanced visual acuity and image perception following correction of highly aberrated eyes using an adaptive optics visual simulator.

    PubMed

    Rocha, Karolinne Maia; Vabre, Laurent; Chateau, Nicolas; Krueger, Ronald R

    2010-01-01

    To evaluate the changes in visual acuity and visual perception generated by correcting higher order aberrations in highly aberrated eyes using a large-stroke adaptive optics visual simulator. A crx1 Adaptive Optics Visual Simulator (Imagine Eyes) was used to correct and modify the wavefront aberrations in 12 keratoconic eyes and 8 symptomatic postoperative refractive surgery (LASIK) eyes. After measuring ocular aberrations, the device was programmed to compensate for the eye's wavefront error from the second order to the fifth order (6-mm pupil). Visual acuity was assessed through the adaptive optics system using computer-generated ETDRS opto-types and the Freiburg Visual Acuity and Contrast Test. Mean higher order aberration root-mean-square (RMS) errors in the keratoconus and symptomatic LASIK eyes were 1.88+/-0.99 microm and 1.62+/-0.79 microm (6-mm pupil), respectively. The visual simulator correction of the higher order aberrations present in the keratoconus eyes improved their visual acuity by a mean of 2 lines when compared to their best spherocylinder correction (mean decimal visual acuity with spherocylindrical correction was 0.31+/-0.18 and improved to 0.44+/-0.23 with higher order aberration correction). In the symptomatic LASIK eyes, the mean decimal visual acuity with spherocylindrical correction improved from 0.54+/-0.16 to 0.71+/-0.13 with higher order aberration correction. The visual perception of ETDRS letters was improved when correcting higher order aberrations. The adaptive optics visual simulator can effectively measure and compensate for higher order aberrations (second to fifth order), which are associated with diminished visual acuity and perception in highly aberrated eyes. The adaptive optics technology may be of clinical benefit when counseling patients with highly aberrated eyes regarding their maximum subjective potential for vision correction. Copyright 2010, SLACK Incorporated.

  12. Significant and variable linear polarization during the prompt optical flash of GRB 160625B.

    PubMed

    Troja, E; Lipunov, V M; Mundell, C G; Butler, N R; Watson, A M; Kobayashi, S; Cenko, S B; Marshall, F E; Ricci, R; Fruchter, A; Wieringa, M H; Gorbovskoy, E S; Kornilov, V; Kutyrev, A; Lee, W H; Toy, V; Tyurina, N V; Budnev, N M; Buckley, D A H; González, J; Gress, O; Horesh, A; Panasyuk, M I; Prochaska, J X; Ramirez-Ruiz, E; Lopez, R Rebolo; Richer, M G; Román-Zúñiga, C; Serra-Ricart, M; Yurkov, V; Gehrels, N

    2017-07-26

    Newly formed black holes of stellar mass launch collimated outflows (jets) of ionized matter that approach the speed of light. These outflows power prompt, brief and intense flashes of γ-rays known as γ-ray bursts (GRBs), followed by longer-lived afterglow radiation that is detected across the electromagnetic spectrum. Measuring the polarization of the observed GRB radiation provides a direct probe of the magnetic fields in the collimated jets. Rapid-response polarimetric observations of newly discovered bursts have probed the initial afterglow phase, and show that, minutes after the prompt emission has ended, the degree of linear polarization can be as high as 30 per cent-consistent with the idea that a stable, globally ordered magnetic field permeates the jet at large distances from the central source. By contrast, optical and γ-ray observations during the prompt phase have led to discordant and often controversial results, and no definitive conclusions have been reached regarding the origin of the prompt radiation or the configuration of the magnetic field. Here we report the detection of substantial (8.3 ± 0.8 per cent from our most conservative simulation), variable linear polarization of a prompt optical flash that accompanied the extremely energetic and long-lived prompt γ-ray emission from GRB 160625B. Our measurements probe the structure of the magnetic field at an early stage of the jet, closer to its central black hole, and show that the prompt phase is produced via fast-cooling synchrotron radiation in a large-scale magnetic field that is advected from the black hole and distorted by dissipation processes within the jet.

  13. Significant and variable linear polarization during the prompt optical flash of GRB 160625B.

    NASA Astrophysics Data System (ADS)

    Troja, E.; Lipunov, V. M.; Mundell, C. G.; Butler, N. R.; Watson, A. M.; Kobayashi, S.; Cenko, S. B.; Marshall, F. E.; Ricci, R.; Fruchter, A.; Wieringa, M. H.; Gorbovskoy, E. S.; Kornilov, V.; Kutyrev, A.; Lee, W. H.; Toy, V.; Tyurina, N. V.; Budnev, N. M.; Buckley, D. A. H.; González, J.; Gress, O.; Horesh, A.; Panasyuk, M. I.; Prochaska, J. X.; Ramirez-Ruiz, E.; Rebolo Lopez, R.; Richer, M. G.; Roman-Zuniga, C.; Serra-Ricart, M.; Yurkov, V.; Gehrels, N.

    2017-07-01

    Newly formed black holes of stellar mass launch collimated outflows (jets) of ionized matter that approach the speed of light. These outflows power prompt, brief and intense flashes of γ-rays known as γ-ray bursts (GRBs), followed by longer-lived afterglow radiation that is detected across the electromagnetic spectrum. Measuring the polarization of the observed GRB radiation provides a direct probe of the magnetic fields in the collimated jets. Rapid-response polarimetric observations of newly discovered bursts have probed the initial afterglow phase, and show that, minutes after the prompt emission has ended, the degree of linear polarization can be as high as 30 per cent - consistent with the idea that a stable, globally ordered magnetic field permeates the jet at large distances from the central source. By contrast, optical and γ-ray observations during the prompt phase have led to discordant and often controversial results, and no definitive conclusions have been reached regarding the origin of the prompt radiation or the configuration of the magnetic field. Here we report the detection of substantial (8.3 ± 0.8 per cent from our most conservative simulation), variable linear polarization of a prompt optical flash that accompanied the extremely energetic and long-lived prompt γ-ray emission from GRB 160625B. Our measurements probe the structure of the magnetic field at an early stage of the jet, closer to its central black hole, and show that the prompt phase is produced via fast-cooling synchrotron radiation in a large-scale magnetic field that is advected from the black hole and distorted by dissipation processes within the jet.

  14. Cyclosporine A does not prevent second-eye involvement in Leber's hereditary optic neuropathy.

    PubMed

    Leruez, Stéphanie; Verny, Christophe; Bonneau, Dominique; Procaccio, Vincent; Lenaers, Guy; Amati-Bonneau, Patrizia; Reynier, Pascal; Scherer, Clarisse; Prundean, Adriana; Orssaud, Christophe; Zanlonghi, Xavier; Rougier, Marie-Bénédicte; Tilikete, Caroline; Miléa, Dan

    2018-02-17

    Evaluation of the efficacy of oral cyclosporine A as a prophylactic agent in preventing second-eye involvement in Leber's hereditary optic neuropathy (LHON) in a prospective, open-label, non-randomized, multicenter pilot study. Only LHON patients aged 18 years or more, with confirmed primary mitochondrial DNA mutations and strictly unilateral optic neuropathy occurring within 6 months prior to enrolment, were included in the study. All these patients, receiving treatment with oral cyclosporine (Neoral®, Novartis) at 2.5 mg/kg/day, were examined at three-month intervals for a year. The primary endpoint was the best corrected visual acuity in the unaffected eye; the secondary endpoints were the best corrected visual acuity in the first eye affected, the mean visual field defect on automated perimetry, the thickness of the perifoveal retinal ganglion cell inner plexiform layer, and the thickness of the peripapillary retinal nerve fiber layer in both eyes. Among the 24 patients referred to our institution with genetically confirmed LHON, between July 2011 and April 2014, only five patients, four males and one female, fulfilled the inclusion criteria. Age at enrolment ranged from 19 to 42 years (mean: 27.2 years; median: 26 years), four patients harbored the m.11778G > A pathogenic variant, and one the m.14484 T > C pathogenic variant. The time-interval between the onset of symptoms and inclusion in the study ranged from 7 to 17 weeks (mean: 11.8 weeks; median: 9 weeks). Despite treatment with oral cyclosporine A, all patients eventually experienced bilateral eye involvement, occurring within 11-65 weeks after the initiation of treatment. Over the study time period, the average best corrected visual acuity worsened in the first eye affected; by the end of the study, both eyes were equally affected. Oral cyclosporine, at 2.5 mg/kg/day, did not prevent second-eye involvement in patients with strictly unilateral Leber's hereditary optic neuropathy

  15. On the timing between terrestrial gamma ray flashes, radio atmospherics, and optical lightning emission

    NASA Astrophysics Data System (ADS)

    Gjesteland, Thomas; Østgaard, Nikolai; Bitzer, Phillip; Christian, Hugh J.

    2017-07-01

    On 25 October 2012 the Reuven Ramaty High Energy Solar Spectroscope Imager (RHESSI) and the Tropical Rainfall Measuring Mission (TRMM) satellites passed over a thunderstorm on the coast of Sri Lanka. RHESSI observed a terrestrial gamma ray flash (TGF) originating from this thunderstorm. Optical measurements of the causative lightning stroke were made by the lightning imaging sensor (LIS) on board TRMM. The World Wide Lightning Location Network (WWLLN) detected the very low frequency (VLF) radio emissions from the lightning stroke. The geolocation from WWLLN, which we also assume is the TGF source location, was in the convective core of the cloud. By using new information about both RHESSI and LIS timing accuracy, we find that the peak in the TGF light curve occurs 230 μs before the WWLLN time. Analysis of the optical signal from LIS shows that within the uncertainties, we cannot conclude which comes first: the gamma emission or the optical emission. We have also applied the new information about the LIS timing on a previously published event by Østgaard et al. (2012). Also for this event we are not able to conclude which signal comes first. More accurate instruments are needed in order to get the exact timing between the TGF and the optical signal.

  16. Structural and optical properties of the naked and passivated Al{sub 5}Au{sub 5} bimetallic nanoclusters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grande-Aztatzi, Rafael; Formoso, Elena; Matxain, Jon M.

    The structural and optical properties of both the naked and passivated bimetallic Al{sub 5}Au{sub 5} nanoclusters have been analyzed based on data obtained from ab initio density functional theory and quantum molecular dynamics simulations. It has been found that the Al{sub 5}Au{sub 5} nanocluster possesses a hollow shaped minimum energy structure with segregated Al and Au layered domains, the former representing the electrophilic domain and the latter the nucleophilic domain. In particular, it has been shown that alkali metal cations attach in the nucleophilic domain and hop from one Au site to the next one in the picoseconds time scale,more » while anions are bound tightly to the Al atoms of the electrophilic domain. Simulating annealing studies are very suggestive of the proneness of the nanocluster towards coalescence into large cluster units, when the cluster is left unprotected by appropriate ligands. Further passivation studies with NaF salt suggest, nonetheless, the possibility of the isolation of the Al{sub 5}Au{sub 5} cluster in molten salts or ionic liquids.« less

  17. Particle creation by naked singularities in higher dimensions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyamoto, Umpei; Nemoto, Hiroya; Shimano, Masahiro

    Recently, the possibility was pointed out by one of the present authors and his collaborators that an effective naked singularity referred to as ''a visible border of spacetime'' is generated by high-energy particle collision in the context of large extra dimensions or TeV-scale gravity. In this paper, we investigate the particle creation by a naked singularity in general dimensions, while adopting a model in which a marginally naked singularity forms in the collapse of a homothetic lightlike pressureless fluid. We find that the spectrum deviates from that of Hawking radiation due to scattering near the singularity but can be recastmore » in quasithermal form. The temperature is always higher than that of Hawking radiation of a same-mass black hole, and can be arbitrarily high depending on a parameter in the model. This implies that, in principle, the naked singularity may be distinguished from a black hole in collider experiments.« less

  18. Gamma ray flashes add to mystery of upper atmosphere

    NASA Astrophysics Data System (ADS)

    Atmospheric electricity research has come a long way since Benjamin Franklin's kite-flying days. But what researchers have been learning lately about above-thunderstorm electricity has wrought a whole new era of mysteries.For a start, last summer a Colorado meteorologist sparked interest in a terrestrial phenomenon that the community first observed more than 100 years ago: optical flashes that occur above thunderstorms—at least 30 km above Earth. Walter Lyons with the Ft. Collins-based Mission Research Corporation, demonstrated that such flashes are not anomalies, as conventional scientific wisdom had held. He filmed hundreds of flashes during a 2-week period.

  19. Structural and optical properties of tin disulphide thin films grown by flash evaporation

    NASA Astrophysics Data System (ADS)

    Banotra, Arun; Padha, Naresh

    2018-04-01

    Tin Disulphide thin films were deposited by Flash Evaporation method on corning Glass Substrate at different substrate temperatures. The deposited films were undertaken for Structural, Optical and compositional characterizations. Compositional analysis of the films exhibited decrease in the sulphur content enabling S/Sn ratio to vary from 2.05 to 1.32 with increasing substrate temperature. X-ray diffraction reveals amorphous nature of the as-deposited films with varying substrate temperatures. Optical measurements estimated from absorbance spectra suggest higher absorbance at λ≤500nm and higher transmission at λ≥500nm with bandgap changes from 2.45eV to 2.09eV. The 323K as-deposited films were undertaken for annealing which transforms the films into crystalline form corresponding to hexagonal SnS2 phase at 423K and above. However, the optical response for the annealed samples shows a higher transmission of 70% in the visible region which increases further in the Infrared region of the spectrum achieving maximum transmission upto 98%. This higher transmission in the Visible to Infrared region of the solar spectrum in amorphous as well as crystalline form makes the film suitable for their use as a window layer in the Solar Cell Design.

  20. Measurement of retinal nerve fiber layer thickness in eyes with optic disc swelling by using scanning laser polarimetry and optical coherence tomography.

    PubMed

    Hata, Masayuki; Miyamoto, Kazuaki; Oishi, Akio; Kimura, Yugo; Nakagawa, Satoko; Horii, Takahiro; Yoshimura, Nagahisa

    2014-01-01

    The retinal nerve fiber layer thickness (RNFLT) in patients with optic disc swelling of different etiologies was compared using scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (OCT). Forty-seven patients with optic disc swelling participated in the cross-sectional study. Both GDx SLP (enhanced corneal compensation) and Spectralis spectral-domain OCT measurements of RNFLT were made in 19 eyes with papilledema (PE), ten eyes with optic neuritis (ON), and 18 eyes with nonarteritic anterior ischemic optic neuropathy (NAION) at the neuro-ophthalmology clinic at Kyoto University Hospital. Differences in SLP (SLP-RNFLT) and OCT (OCT-RNFLT) measurements among different etiologies were investigated. No statistical differences in average OCT-RNFLT among PE, ON, and NAION patients were noted. Average SLP-RNFLT in NAION patients was smaller than in PE (P<0.01) or ON (P=0.02) patients. When RNFLT in each retinal quadrant was compared, no difference among etiologies was noted on OCT, but on SLP, the superior quadrant was thinner in NAION than in PE (P<0.001) or ON (P=0.001) patients. Compared with age-adjusted normative data of SLP-RNFLT, average SLP-RNFLT in PE (P<0.01) and ON (P<0.01) patients was greater. Superior SLP-RNFLT in NAION patients was smaller (P=0.026). The ratio of average SLP-RNFLT to average OCT-RNFLT was smaller in NAION than in PE (P=0.001) patients. In the setting of RNFL thickening, despite increased light retardance in PE and ON eyes, SLP revealed that NAION eyes have less retardance, possibly associated with ischemic axonal loss.

  1. Measurement of retinal nerve fiber layer thickness in eyes with optic disc swelling by using scanning laser polarimetry and optical coherence tomography

    PubMed Central

    Hata, Masayuki; Miyamoto, Kazuaki; Oishi, Akio; Kimura, Yugo; Nakagawa, Satoko; Horii, Takahiro; Yoshimura, Nagahisa

    2014-01-01

    Background The retinal nerve fiber layer thickness (RNFLT) in patients with optic disc swelling of different etiologies was compared using scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (OCT). Methods Forty-seven patients with optic disc swelling participated in the cross-sectional study. Both GDx SLP (enhanced corneal compensation) and Spectralis spectral-domain OCT measurements of RNFLT were made in 19 eyes with papilledema (PE), ten eyes with optic neuritis (ON), and 18 eyes with nonarteritic anterior ischemic optic neuropathy (NAION) at the neuro-ophthalmology clinic at Kyoto University Hospital. Differences in SLP (SLP-RNFLT) and OCT (OCT-RNFLT) measurements among different etiologies were investigated. Results No statistical differences in average OCT-RNFLT among PE, ON, and NAION patients were noted. Average SLP-RNFLT in NAION patients was smaller than in PE (P<0.01) or ON (P=0.02) patients. When RNFLT in each retinal quadrant was compared, no difference among etiologies was noted on OCT, but on SLP, the superior quadrant was thinner in NAION than in PE (P<0.001) or ON (P=0.001) patients. Compared with age-adjusted normative data of SLP-RNFLT, average SLP-RNFLT in PE (P<0.01) and ON (P<0.01) patients was greater. Superior SLP-RNFLT in NAION patients was smaller (P=0.026). The ratio of average SLP-RNFLT to average OCT-RNFLT was smaller in NAION than in PE (P=0.001) patients. Conclusion In the setting of RNFL thickening, despite increased light retardance in PE and ON eyes, SLP revealed that NAION eyes have less retardance, possibly associated with ischemic axonal loss. PMID:24379653

  2. Potential Use of a Bayesian Network for Discriminating Flash Type from Future GOES-R Geostationary Lightning Mapper (GLM) data

    NASA Technical Reports Server (NTRS)

    Solakiewiz, Richard; Koshak, William

    2008-01-01

    Continuous monitoring of the ratio of cloud flashes to ground flashes may provide a better understanding of thunderstorm dynamics, intensification, and evolution, and it may be useful in severe weather warning. The National Lighting Detection Network TM (NLDN) senses ground flashes with exceptional detection efficiency and accuracy over most of the continental United States. A proposed Geostationary Lightning Mapper (GLM) aboard the Geostationary Operational Environmental Satellite (GOES-R) will look at the western hemisphere, and among the lightning data products to be made available will be the fundamental optical flash parameters for both cloud and ground flashes: radiance, area, duration, number of optical groups, and number of optical events. Previous studies have demonstrated that the optical flash parameter statistics of ground and cloud lightning, which are observable from space, are significantly different. This study investigates a Bayesian network methodology for discriminating lightning flash type (ground or cloud) using the lightning optical data and ancillary GOES-R data. A Directed Acyclic Graph (DAG) is set up with lightning as a "root" and data observed by GLM as the "leaves." This allows for a direct calculation of the joint probability distribution function for the lighting type and radiance, area, etc. Initially, the conditional probabilities that will be required can be estimated from the Lightning Imaging Sensor (LIS) and the Optical Transient Detector (OTD) together with NLDN data. Directly manipulating the joint distribution will yield the conditional probability that a lightning flash is a ground flash given the evidence, which consists of the observed lightning optical data [and possibly cloud data retrieved from the GOES-R Advanced Baseline Imager (ABI) in a more mature Bayesian network configuration]. Later, actual GLM and NLDN data can be used to refine the estimates of the conditional probabilities used in the model; i.e., the Bayesian

  3. Shadow image on the retina of a defocused eye

    NASA Astrophysics Data System (ADS)

    Lenskii, A. V.

    1994-04-01

    Some visual conditions for transparent objects positioned within and beyond the accommodation limits on the path of the light traveling from a remote source of a small angular size are theoretically considered for the naked eye with a strong ametropia. The resolving power and admissible angular size of the light source are evaluated. The predicted possibility of seeing sufficiently extended transparent gratings at such distances has found that the density of ruling of the grating-object is higher than the ultimate angular resolution of the normal eye.

  4. Cat-eye effect reflected beam profiles of an optical system with sensor array.

    PubMed

    Gong, Mali; He, Sifeng; Guo, Rui; Wang, Wei

    2016-06-01

    In this paper, we propose an applicable propagation model for Gaussian beams passing through any cat-eye target instead of traditional simplification consisting of only a mirror placed at the focal plane of a lens. According to the model, the cat-eye effect of CCD cameras affected by defocus is numerically simulated. An excellent agreement of experiment results with theoretical analysis is obtained. It is found that the reflectivity distribution at the focal plane of the cat-eye optical lens has great influence on the results, while the cat-eye effect reflected beam profiles of CCD cameras show obvious periodicity.

  5. Computerized Scheimpflug densitometry as a measure of corneal optical density after excimer laser refractive surgery in myopic eyes.

    PubMed

    Cennamo, Gilda; Forte, Raimondo; Aufiero, Bernardino; La Rana, Agostino

    2011-08-01

    To evaluate changes in anterior corneal optical density and the refractive index after photorefractive keratectomy (PRK) using a rotating Scheimpflug system. Department of Ophthalmology, University Federico II, Naples, Italy. Comparative case series. Anterior corneal optical density was evaluated with a rotating Scheimpflug system at baseline and 3 months and 12 months after PRK in eyes with a refractive error between -6.00 diopters (D) and -12.00 D (study group). A control group of unoperated eyes with the same refraction range was used to calculate corneal optical density and the Gladstone-Dale constant in unoperated eyes using the Gladstone-Dale formula. In the study group, changes in the anterior corneal optical density were evaluated over time and variations in the anterior corneal refractive index were obtained using the Gladstone-Dale constant. The study group comprised 37 eyes and the control group, 200 eyes. In the study group, the mean anterior corneal optical density and refractive index, respectively, were 27.71 ± 4.39 and 1.360 ± 0.05 at baseline, 37.812 ± 12.31 and 1.491 ± 0.16 after 3 months (P<.001 compared with baseline), and 26.29 ± 4.93 and 1.341 ± 0.06 after 12 months (P=.03 compared with baseline). The mean corneal optical density in the control group was 27.71 ± 4.31 (SD), and the resultant Gladstone-Dale constant was 0.013. An early increase and a subsequent reduction in anterior corneal optical density and the refractive index were present in myopic eyes during 1 year after PRK. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Aberrations in square pore micro-channel optics used for x-ray lobster eye telescopes

    NASA Astrophysics Data System (ADS)

    Willingale, R.; Pearson, J. F.; Martindale, A.; Feldman, C. H.; Fairbend, R.; Schyns, E.; Petit, S.; Osborne, J. P.; O'Brien, P. T.

    2016-07-01

    We identify all the significant aberrations that limit the performance of square pore micro-channel plate optics (MPOs) used as an X-ray lobster eye. These include aberrations intrinsic to the geometry, intrinsic errors associated with the slumping process used to introduce a spherical form to the plates and imperfections associated with the plate manufacturing process. The aberrations are incorporated into a comprehensive software model of the X-ray response of the optics and the predicted imaging response is compared with the measured X-ray performance obtained from a breadboard lobster eye. The results reveal the manufacturing tolerances which limit the current performance of MPOs and enable us to identify particular intrinsic aberrations which will limit the ultimate performance we can expect from MPO-lobster eye telescopes.

  7. Flashes of light-radiation therapy to the brain.

    PubMed

    Blumenthal, Deborah T; Corn, Benjamin W; Shtraus, Natan

    2015-08-01

    We present a series of three patients who received therapeutic external beam radiation to the brain and experienced a phenomenon of the sensation of flashes of bright or blue light, simultaneous with radiation delivery. We relate this benign phenomenon to low-dose exposure to the eye fields and postulate that the occurrence is underreported in this treated population. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. HOW ELSE CAN WE DETECT FAST RADIO BURSTS?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyutikov, Maxim; Lorimer, Duncan R., E-mail: lyutikov@purdue.edu

    We discuss possible electromagnetic signals accompanying Fast Radio Bursts (FRBs) that are expected in the scenario where FRBs originate in neutron star magnetospheres. For models involving Crab-like giant pulses, no appreciable contemporaneous emission is expected at other wavelengths. However, magnetar giant flares, driven by the reconfiguration of the magnetosphere, can produce both contemporaneous bursts at other wavelengths as well as afterglow-like emission. We conclude that the best chances are: (i) prompt short GRB-like emission, (ii) a contemporaneous optical flash that can reach naked eye peak luminosity (but only for a few milliseconds), and (iii) a high-energy afterglow emission. Case (i)more » could be tested by coordinated radio and high-energy experiments. Case (ii) could be seen in a coordinated radio-optical surveys, e.g., by the Palomar Transient Factory in a 60 s frame as a transient object of m = 15–20 mag with an expected optical detection rate of about 0.1 hr{sup −1}, an order of magnitude higher than in radio. Shallow, but large-area sky surveys such as ASAS-SN and EVRYSCOPE could also detect prompt optical flashes from the more powerful Lorimer-burst clones. The best constraints on the optical to radio power for this kind of emission could be provided by future observations with facilities like Large Synoptic Survey Telescope. Case (iii) might be seen in relatively rare cases that the relativistically ejected magnetic blob is moving along the line of sight.« less

  9. Efferent control of temporal response properties of the Limulus lateral eye

    PubMed Central

    1990-01-01

    The sensitivity of the Limulus lateral eye exhibits a pronounced circadian rhythm. At night a circadian oscillator in the brain activates efferent fibers in the optic nerve, inducing multiple changes in the physiological and anatomical characteristics of retinal cells. These changes increase the sensitivity of the retina by about five orders of magnitude. We investigated whether this increase in retinal sensitivity is accompanied by changes in the ability of the retina to process temporal information. We measured the frequency transfer characteristic (FTC) of single receptors (ommatidia) by recording the response of their optic nerve fibers to sinusoidally modulated light. We first measured the FTC in the less sensitive daytime state and then after converting the retina to the more sensitive nighttime state by electrical stimulation of the efferent fibers. The activation of these fibers shifted the peak of the FTC to lower frequencies and reduced the slope of the low-frequency limb. These changes reduce the eye's ability to detect rapid changes in light intensity but enhance its ability to detect dim flashes of light. Apparently Limulus sacrifices temporal resolution for increased visual sensitivity at night. PMID:2307958

  10. REPRODUCIBILITY OF VESSEL DENSITY MEASUREMENT WITH OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IN EYES WITH AND WITHOUT RETINOPATHY.

    PubMed

    You, Qisheng; Freeman, William R; Weinreb, Robert N; Zangwill, Linda; Manalastas, Patricia I C; Saunders, Luke J; Nudleman, Eric

    2017-08-01

    To determine the intravisit and intervisit reproducibility of optical coherence tomography angiography measurements of macular vessel density in eyes with and without retinal diseases. Fifteen healthy volunteers and 22 patients with retinal diseases underwent repeated optical coherence tomography angiography (Angiovue Imaging System, Optovue Inc) scans after pupil dilation on 2 separate visit days. For each visit day, the eyes were scanned twice. Vessel density defined as the proportion of vessel area with flowing blood over the total measurement area was calculated using Angiovue software. Intravisit and intervisit reproducibility were summarized as coefficient of variations and intraclass correlation coefficients were calculated from variance component models. The coefficient of variations representing the intravisit reproducibility of the superficial macular vessel density measurements for different quadrants on 3 mm × 3-mm scans varied from 2.1% to 4.9% and 3.4% to 6.8% for healthy and diseased eyes, respectively, and for the intervisit it was 2.9% to 5.1% and 4.0% to 6.8%, respectively. The coefficient of variations were lower in healthy eyes than in diseased eyes, lower for intravisit than for intervisit, lower on 3 mm × 3-mm scans than on 6 mm × 6-mm scans, and lower for paracentral subfields than for central subfield. The evidence presented here demonstrates good reproducibility of optical coherence tomography angiography for measurement of superficial macula vessel density in both healthy eyes and eyes with diabetic retinopathy without diabetic macular edema.

  11. The Remarkable Afterglow of GRB 061007: Implications for Optical Flashes and GRB Fireballs

    NASA Astrophysics Data System (ADS)

    Mundell, C. G.; Melandri, A.; Guidorzi, C.; Kobayashi, S.; Steele, I. A.; Malesani, D.; Amati, L.; D'Avanzo, P.; Bersier, D. F.; Gomboc, A.; Rol, E.; Bode, M. F.; Carter, D.; Mottram, C. J.; Monfardini, A.; Smith, R. J.; Malhotra, S.; Wang, J.; Bannister, N.; O'Brien, P. T.; Tanvir, N. R.

    2007-05-01

    We present a multiwavelength analysis of Swift GRB 061007. The 2 m robotic Faulkes Telescope South began observing 137 s after the onset of the γ-ray emission, when the optical counterpart was already decaying from R~10.3 mag, and continued observing for the next 5.5 hr. These observations begin during the final γ-ray flare and continue through and beyond a long, soft tail of γ-ray emission whose flux shows an underlying simple power-law decay identical to that seen at optical and X-ray wavelengths, with temporal slope α~1.7 (F~t-α). This remarkably simple decay in all of these bands is rare for Swift bursts, which often show much more complex light curves. We suggest the afterglow emission begins as early as 30-100 s and is contemporaneous with the ongoing variable prompt emission from the central engine, but originates from a physically distinct region dominated by the forward shock. The observed multiwavelength evolution of GRB 061007 is explained by an expanding fireball whose optical, X-ray, and late-time γ-ray emission is dominated by emission from a forward shock with typical synchrotron frequency, νm, that is already below the optical band as early as t=137 s and a cooling frequency, νc, above the X-ray band to at least t=105 s. In contrast, the typical frequency of the reverse shock lies in the radio band at early time. We suggest that the unexpected lack of bright optical flashes from the majority of Swift GRBs may be explained with a low νm originating from small microphysics parameters, ɛe and ɛB. Finally, the optical light curves imply a minimum jet opening angle θ=4.7deg, and no X-ray jet break before t~106 s makes GRB 061007 a secure outlier to spectral energy correlations.

  12. Reliability of unaided naked-eye examination as a screening test for cervical lesions in a developing country setup.

    PubMed

    Darwish, Atef M; Abdulla, Sayed A; Zahran, Kamal M; Abdel-Fattah, Nermat A

    2013-04-01

    This study aimed to test the reliability of unaided naked-eye examination (UNEE) of the cervix as a sole cervical cancer screening test in a developing country setup compared with the standard cervical cytology. A total of 3,500 nonpregnant women aged between 25 and 55 years were included. An unlubricated bivalve speculum was inserted into the vagina under good light to visualize the cervix. A thorough UNEE of the cervix was done to detect any apparent lesions. Cervical smears were obtained using the long tip of an Ayre spatula. An additional endocervical sample was obtained by cytobrush. Women with abnormal Pap smears or visible cervical lesions by UNEE were scheduled for colposcopic examination. A biopsy specimen was obtained in every abnormal colposcopic examination. Of 3,500 cases, there were 9 (2.57%) preinvasive cervical lesions (cervical intraepithelial neoplasia 1-3) diagnosed with various diagnostic tools used in the study and confirmed by histopathologic examination. Of 3,500 cases, invasive cervical lesions were diagnosed in 6 (1.71%). The sensitivity of UNEE is much better than that of Pap smear (80% vs 60%) but less than that of colposcopy (86.7%). However, the specificity of UNEE (100%) is lower than that of Pap smear (91.16%) and better than that colposcopy (83.12%). The UNEE has a poor positive predictive value (3.75%) when compared with Pap smear (100%) and colposcopy (20%). The negative predictive values of the 3 tests were nearly comparable. Whenever access to Pap smear is limited, UNEE performed by general gynecologists and well-trained nurses is an acceptable alternative for detecting cervical premalignant or malignant lesions especially in low-resource settings.

  13. Versatile aptasensor for electrochemical quantification of cell surface glycan and naked-eye tracking glycolytic inhibition in living cells.

    PubMed

    Zhang, Jing-Jing; Cheng, Fang-Fang; Zheng, Ting-Ting; Zhu, Jun-Jie

    2017-03-15

    Quantifying the glycan expression status on cell surfaces is of vital importance for insight into the glycan function in biological processes and related diseases. Here we developed a versatile aptasensor for electrochemical quantification of cell surface glycan by taking advantage of the cell-specific aptamer, and the lectin-functionalized gold nanoparticles acting as both a glycan recognition unit and a signal amplification probe. To construct the aptasensor, amine-functionalized mucin 1 protein (MUC1) aptamer was first covalently conjugated to carboxylated-magnetic beads (MBs) using the succinimide coupling (EDC-NHS) method. On the basis of the specific recognition between aptamer and MUC1 protein that overexpressed on the surface of MCF-7 cells, the aptamer conjugated MBs showed a predominant capability for cell capture with high selectivity. Moreover, a lectin-based nanoprobe was designed by noncovalent assembly of concanavalin A (ConA) on gold nanoparticles (AuNPs). This nanoprobe incorporated the abilities of both the specific carbohydrate recognition and the signal amplification based on the gold-promoted reduction of silver ions. By coupling with electrochemical stripping analysis, the proposed sandwich-type cytosensor showed an excellent analytical performance for the ultrasensitive detection of MCF-7 cells and quantification of cell surface glycan. More importantly, taking advantage of Con A-gold nanoprobe catalyzed silver enhancement, the proposed method was further used for naked-eye tracking glycolytic inhibition in living cells. This aptasensor holds great promise as a new point-of-care diagnostic tool for analyzing glycan expression on living cells and further helps cancer diagnosis and treatment. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Echo scintillation Index affected by cat-eye target's caliber with Cassegrain lens

    NASA Astrophysics Data System (ADS)

    Shan, Cong-miao; Sun, Hua-yan; Zhao, Yan-zhong; Zheng, Yong-hui

    2015-10-01

    The optical aperture of cat-eye target has the aperture averaging effect to the active detecting laser of active laser detection system, which can be used to identify optical targets. The echo scintillation characteristics of the transmission-type lens target have been studied in previous work. Discussing the differences of the echo scintillation characteristics between the transmission-type lens target and Cassegrain lens target can be helpful to targets classified. In this paper, the echo scintillation characteristics of Cat-eye target's caliber with Cassegrain lens has been discussed . By using the flashing theory of spherical wave in the weak atmospheric turbulence, the annular aperture filter function and the Kolmogorov power spectrum, the analytic expression of the scintillation index of the cat-eye target echo of the horizontal path two-way transmission was given when the light is normal incidence. Then the impact of turbulence inner and outer scale to the echo scintillation index and the analytic expression of the echo scintillation index at the receiving aperture were presented using the modified Hill spectrum and the modified Von Karman spectrum. Echo scintillation index shows the tendency of decreasing with the target aperture increases and different ratios of the inner and outer aperture diameter show the different echo scintillation index curves. This conclusion has a certain significance for target recognition in the active laser detection system that can largely determine the target type by largely determining the scope of the cat-eye target which depending on echo scintillation index.

  15. Profile and Determinants of Retinal Optical Intensity in Normal Eyes with Spectral Domain Optical Coherence Tomography.

    PubMed

    Chen, Binyao; Gao, Enting; Chen, Haoyu; Yang, Jianling; Shi, Fei; Zheng, Ce; Zhu, Weifang; Xiang, Dehui; Chen, Xinjian; Zhang, Mingzhi

    2016-01-01

    To investigate the profile and determinants of retinal optical intensity in normal subjects using 3D spectral domain optical coherence tomography (SD OCT). A total of 231 eyes from 231 healthy subjects ranging in age from 18 to 80 years were included and underwent a 3D OCT scan. Forty-four eyes were randomly chosen to be scanned by two operators for reproducibility analysis. Distribution of optical intensity of each layer and regions specified by the Early Treatment of Diabetic Retinopathy Study (ETDRS) were investigated by analyzing the OCT raw data with our automatic graph-based algorithm. Univariate and multivariate analyses were performed between retinal optical intensity and sex, age, height, weight, spherical equivalent (SE), axial length, image quality, disc area and rim/disc area ratio (R/D area ratio). For optical intensity measurements, the intraclass correlation coefficient of each layer ranged from 0.815 to 0.941, indicating good reproducibility. Optical intensity was lowest in the central area of retinal nerve fiber layer, ganglion cell layer, inner plexiform layer, inner nuclear layer, outer plexiform layer and photoreceptor layer, except for the retinal pigment epithelium (RPE). Optical intensity was positively correlated with image quality in all retinal layers (0.553<β<0.851, p<0.01), and negatively correlated with age in most retinal layers (-0.362<β<-0.179, p<0.01), except for the RPE (β = 0.456, p<0.01), outer nuclear layer and photoreceptor layer (p>0.05). There was no relationship between retinal optical intensity and sex, height, weight, SE, axial length, disc area and R/D area ratio. There was a specific pattern of distribution of retinal optical intensity in different regions. The optical intensity was affected by image quality and age. Image quality can be used as a reference for normalization. The effect of age needs to be taken into consideration when using OCT for diagnosis.

  16. Naked-eye inspection of the cervix after acetic acid application may improve the predictive value of negative cytologic screening.

    PubMed

    Frisch, L E; Milner, F H; Ferris, D G

    1994-11-01

    The purpose of this study was to assess the predictive value of naked-eye inspection of the cervix (NIC) after acetic acid application as an adjunct to Papanicolaou (Pap) testing for cervical cancer screening. Study subjects were women attending a medical college student health clinic either for cervical cytologic screening (67%) or because of a recent atypical cytologic screening result (33%). All study participants received cytologic screening, cervicography, and NIC. Of the 95 patients, 71 (75%) had abnormal findings on NIC. Fifty-one patients underwent colposcopy with biopsy, including 48 of the 71 with an abnormal finding on NIC. The results of 40 of the biopsies were abnormal: 36 showed human papillomavirus or low-grade squamous intraepithelial lesions, 3 showed high-grade squamous intraepithelial lesions, and 1 showed invasive cervical cancer. Sixty-five percent (26) of the abnormal biopsy findings occurred in women with normal cytologic test results. NIC and cervicography both were effective in identifying patients with abnormalities, but the combination of NIC followed by cervicography referred fewer women for colposcopy than did a positive result on NIC alone (52% vs 75%). The combination of a negative Pap smear and a negative NIC result had a 91% predictive value for the absence of cervical intraepithelial neoplasia. This was a significant improvement over cytologic screening alone. In this study, the combination of cytologic screening (Pap smear) and NIC increased the screening yield as compared with a Pap smear alone but with some loss of positive predictive value. NIC significantly improved the predictive value of negative cytologic screening results.

  17. Role of nuclear stars in the light flashes observed on Skylab 4.

    PubMed

    McNulty, P J; Filz, R C; Rothwell, P L

    1977-01-01

    The astronauts on Skylab 4 observed bursts of intense visual light-flash activity when their spacecraft passed through the portion of the earth's inner trapped radiation belt known as the South Atlantic Anomaly (SAA). Two experimental sessions were carried out on board Skylab 4 under the auspices of Pinsky et al. who compare the flash rates with the measured flux of Z > or = 1 particles that would pass through the astronaut's eyes. They concluded that the flash rates, which became as great as 20/min, were anomalously high. We explored a number of alternative explanations for the anomalous flash rates that would be consistent with the accepted SAA flux values and the laboratory data on particle induced visual sensations and found that when one includes the effect of nuclear interactions in and near the retina which result in star formation (the emission of slow protons, neutrons and alpha particles form the nucleus in an evaporation-like process) the apparent anomaly is removed.

  18. Cone structure imaged with adaptive optics scanning laser ophthalmoscopy in eyes with nonneovascular age-related macular degeneration.

    PubMed

    Zayit-Soudry, Shiri; Duncan, Jacque L; Syed, Reema; Menghini, Moreno; Roorda, Austin J

    2013-11-15

    To evaluate cone spacing using adaptive optics scanning laser ophthalmoscopy (AOSLO) in eyes with nonneovascular AMD, and to correlate progression of AOSLO-derived cone measures with standard measures of macular structure. Adaptive optics scanning laser ophthalmoscopy images were obtained over 12 to 21 months from seven patients with AMD including four eyes with geographic atrophy (GA) and four eyes with drusen. Adaptive optics scanning laser ophthalmoscopy images were overlaid with color, infrared, and autofluorescence fundus photographs and spectral domain optical coherence tomography (SD-OCT) images to allow direct correlation of cone parameters with macular structure. Cone spacing was measured for each visit in selected regions including areas over drusen (n = 29), at GA margins (n = 14), and regions without drusen or GA (n = 13) and compared with normal, age-similar values. Adaptive optics scanning laser ophthalmoscopy imaging revealed continuous cone mosaics up to the GA edge and overlying drusen, although reduced cone reflectivity often resulted in hyporeflective AOSLO signals at these locations. Baseline cone spacing measures were normal in 13/13 unaffected regions, 26/28 drusen regions, and 12/14 GA margin regions. Although standard clinical measures showed progression of GA in all study eyes, cone spacing remained within normal ranges in most drusen regions and all GA margin regions. Adaptive optics scanning laser ophthalmoscopy provides adequate resolution for quantitative measurement of cone spacing at the margin of GA and over drusen in eyes with AMD. Although cone spacing was often normal at baseline and remained normal over time, these regions showed focal areas of decreased cone reflectivity. These findings may provide insight into the pathophysiology of AMD progression. (ClinicalTrials.gov number, NCT00254605).

  19. A simple, reversible, colorimetric and water-soluble fluorescent chemosensor for the naked-eye detection of Cu2 + in 100% aqueous media and application to real samples

    NASA Astrophysics Data System (ADS)

    Sun, Tao; Niu, Qingfen; Li, Tianduo; Guo, Zongrang; Liu, Haixia

    2018-01-01

    A simple, reversible, colorimetric and water-soluble fluorescent chemosensor ADA for the naked-eye detection of Cu2 + was developed. Sensor ADA showed high selectivity and sensitivity toward Cu2 + in 100% aqueous media over wide pH range. Sensor ADA exhibited a red-shift in the absorption spectra from 466 to 480 nm that is accompanied by significant color change from light yellow to yellowish brown instantaneously. The Cu2 + recognition is based on the chelation-enhanced fluorescence quenching (CHEQ) effect of the paramagnetic nature. The lowest detection limit is determined to be 15.8 nM, which is much lower than the allowable level of Cu2 + in drinking water set by U.S. Environmental Protection Agency ( 20 μM) and the World Health Organization ( 30 μM). The 1:1 binding process was confirmed by fluorescence measurements, IR analysis and DFT studies. Moreover, sensor ADA was successfully applied for determination of trace level of Cu2 + with 4 reuse cycles in various water samples, which affords promising potential in ion-detection field.

  20. Optical coherence tomography of the preterm eye: from retinopathy of prematurity to brain development

    PubMed Central

    Rothman, Adam L; Mangalesh, Shwetha; Chen, Xi; Toth, Cynthia A

    2016-01-01

    Preterm infants with retinopathy of prematurity are at increased risk of poor neurodevelopmental outcomes. Because the neurosensory retina is an extension of the central nervous system, anatomic abnormalities in the anterior visual pathway often relate to system and central nervous system health. We describe optical coherence tomography as a powerful imaging modality that has recently been adapted to the infant population and provides noninvasive, high-resolution, cross-sectional imaging of the infant eye at the bedside. Optical coherence tomography has increased understanding of normal eye development and has identified several potential biomarkers of brain abnormalities and poorer neurodevelopment. PMID:28539807

  1. A standard model eye with micro scale multilayer structure for ophthalmic optical coherence tomography equipment

    NASA Astrophysics Data System (ADS)

    Cao, Zhenggang; Ding, Zengqian; Hu, Zhixiong; Wen, Tao; Qiao, Wen; Liu, Wenli

    2016-10-01

    Optical coherence tomography (OCT) has been widely applied in diagnosis of eye diseases during the last 20 years. Differing from traditional two-dimension imaging technologies, OCT could also provide cross-sectional information of target tissues simultaneously and precisely. As well known, axial resolution is one of the most critical parameters impacting the OCT image quality, which determines whether an accurate diagnosis could be obtained. Therefore, it is important to evaluate the axial resolution of an OCT equipment. Phantoms always play an important role in the standardization and validation process. Here, a standard model eye with micro-scale multilayer structure was custom designed and manufactured. Mimicking a real human eye, analyzing the physical characteristic of layer structures of retina and cornea in-depth, appropriate materials were selected by testing the scattering coefficient of PDMS phantoms with difference concentration of TiO2 or BaSO4 particles. An artificial retina and cornea with multilayer-films which have a thickness of 10 to 60 micrometers for each layer were fabricated using spin coating technology. Considering key parameters of the standard model eye need to be traceable as well as accurate, the optical refractive index and layer structure thicknesses of phantoms were verified by utilizing Thickness Monitoring System. Consequently, a standard OCT model eye was obtained after the retinal or corneal phantom was embedded into a water-filled model eye which has been fabricated by 3D printing technology to simulate ocular dispersion and emmetropic refraction. The eye model was manufactured with a transparent resin to simulate realistic ophthalmic testing environment, and most key optical elements including cornea, lens and vitreous body were realized. By investigating with a research and a clinical OCT system respectively, the OCT model eye was demonstrated with similar physical properties as natural eye, and the multilayer film measurement

  2. Perfect fluid tori orbiting Kehagias-Sfetsos naked singularities

    NASA Astrophysics Data System (ADS)

    Stuchlík, Z.; Pugliese, D.; Schee, J.; Kučáková, H.

    2015-09-01

    We construct perfect fluid tori in the field of the Kehagias-Sfetsos (K-S) naked singularities. These are spherically symmetric vacuum solutions of the modified Hořava quantum gravity, characterized by a dimensionless parameter ω M^2, combining the gravitational mass parameter M of the spacetime with the Hořava parameter ω reflecting the role of the quantum corrections. In dependence on the value of ω M^2, the K-S naked singularities demonstrate a variety of qualitatively different behavior of their circular geodesics that is fully reflected in the properties of the toroidal structures, demonstrating clear distinction to the properties of the torii in the Schwarzschild spacetimes. In all of the K-S naked singularity spacetimes the tori are located above an "antigravity" sphere where matter can stay in a stable equilibrium position, which is relevant for the stability of the orbiting fluid toroidal accretion structures. The signature of the K-S naked singularity is given by the properties of marginally stable tori orbiting with the uniform distribution of the specific angular momentum of the fluid, l= const. In the K-S naked singularity spacetimes with ω M^2 > 0.2811, doubled tori with the same l= const can exist; mass transfer between the outer torus and the inner one is possible under appropriate conditions, while only outflow to the outer space is allowed in complementary conditions. In the K-S spacetimes with ω M^2 < 0.2811, accretion from cusped perfect fluid tori is not possible due to the non-existence of unstable circular geodesics.

  3. A RESCUE THERAPY FOR PERSISTENT OPTIC DISK PIT MACULOPATHY IN PREVIOUSLY VITRECTOMIZED EYES.

    PubMed

    Figueroa, Marta S; Nadal, Jeroni; Contreras, Inés

    2018-01-01

    To report the results of vitrectomy with platelet-rich plasma (PRP) application and gas tamponade as a rescue therapy in previously vitrectomized eyes with optic disk pit (ODP) maculopathy. Three patients with visual loss due to persistent or recurrent ODP maculopathy who had undergone previous vitrectomy were offered application of PRP. Platelet-rich plasma was obtained by centrifugation of a blood sample from each patient. Surgery consisted of vitrectomy and internal limiting membrane peeling if the membrane had not been already removed (in two eyes). After fluid/air exchange, three drops of PRP were applied on the ODP followed by 8% C3F8 tamponade. Immediately after surgery, the patient remained supine for 30 minutes and then kept a face-down position for 2 weeks. Optic disk pit maculopathy improved as soon as two weeks after surgery and resolved in all eyes between six and eight months after PRP application. Patients were followed up for three years, with no recurrences. Visual acuity remained stable in one eye and improved in two eyes. Vitrectomy with PRP application may be useful as a rescue therapy in patients with refractory ODP maculopathy. Platelet-rich plasma may act by promoting the closure of the communication between the vitreous and the intraretinal/subretinal space at the pit. This treatment may avoid potentially harmful maneuvers that have been used to treat ODP maculopathy.

  4. Post-Cataract Surgery Optic Neuropathy: Prevalence, Incidence, Temporal Relationship, and Fellow Eye Involvement.

    PubMed

    Moradi, Ahmadreza; Kanagalingam, Sivashakthi; Diener-West, Marie; Miller, Neil R

    2017-03-01

    To reassess the prevalence and incidence of post-cataract surgery optic neuropathy (PCSON) in the modern era. Retrospective cohort study. Setting: Single-center tertiary care practice. All patients with a diagnosis of nonarteritic anterior ischemic optic neuropathy (NAION) seen in the Wilmer Eye Network system between January 1, 2010 and December 31, 2014 were included. Inclusion was based on the following: (1) a history of an acute unilateral decrease in vision, (2) a visual field defect consistent with NAION, (3) a relative afferent pupillary defect, (4) observed optic disc swelling, and (5) no other etiology being found. The prevalence and incidence of PCSON and the temporal association between surgery and onset of PCSON. The secondary outcome was the risk of PCSON in the fellow eye of patients with prior unilateral spontaneous NAION. One hundred eighty-eight patients had developed NAION during the study period. Of these, 18 (9.6%) had undergone cataract surgery (CS) during the year prior to developing NAION. There was no significant temporal pattern associated with the distribution of NAION cases (P = .28). The incidence of PCSON in patients who had noncomplex CS was 10.9 cases per 100 000 (95% CI, 1.3, 39.4). Our data indicate that both the prevalence and incidence of NAION after modern CS are comparable to those of the general population and that there is no significant temporal relationship between modern CS and the subsequent development of NAION in the operated eye. Thus, although this study has inherent biases owing to its retrospective nature, concern regarding an increased risk of PCSON in the fellow eye in patients who have experienced it or spontaneous NAION in 1 eye may be unwarranted. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Tracking the eye non-invasively: simultaneous comparison of the scleral search coil and optical tracking techniques in the macaque monkey

    PubMed Central

    Kimmel, Daniel L.; Mammo, Dagem; Newsome, William T.

    2012-01-01

    From human perception to primate neurophysiology, monitoring eye position is critical to the study of vision, attention, oculomotor control, and behavior. Two principal techniques for the precise measurement of eye position—the long-standing sclera-embedded search coil and more recent optical tracking techniques—are in use in various laboratories, but no published study compares the performance of the two methods simultaneously in the same primates. Here we compare two popular systems—a sclera-embedded search coil from C-N-C Engineering and the EyeLink 1000 optical system from SR Research—by recording simultaneously from the same eye in the macaque monkey while the animal performed a simple oculomotor task. We found broad agreement between the two systems, particularly in positional accuracy during fixation, measurement of saccade amplitude, detection of fixational saccades, and sensitivity to subtle changes in eye position from trial to trial. Nonetheless, certain discrepancies persist, particularly elevated saccade peak velocities, post-saccadic ringing, influence of luminance change on reported position, and greater sample-to-sample variation in the optical system. Our study shows that optical performance now rivals that of the search coil, rendering optical systems appropriate for many if not most applications. This finding is consequential, especially for animal subjects, because the optical systems do not require invasive surgery for implantation and repair of search coils around the eye. Our data also allow laboratories using the optical system in human subjects to assess the strengths and limitations of the technique for their own applications. PMID:22912608

  6. Apollo-Soyuz light-flash observations.

    PubMed

    Budinger, T F; Tobias, C A; Huesman, R H; Upham, F T; Wieskamp, T F; Hoffman, R A

    1977-01-01

    While dark adapted, two Apollo-Soyuz astronauts saw eighty-two light flash events during a complete 51 degrees orbit which passed near the north magnetic pole and through the South Atlantic Anomaly. The frequency of events at the polar parts of the orbit is 25 times that noted in equatorial latitudes and no increased frequency was noted in the South Atlantic Anomaly at the 225-km altitude. The expected flux of heavy particles at the northern and southern points is 1-2 min-1 per eye, and the efficiency for seeing HZE particles which were below the Cerenkov threshold is 50%.

  7. Eye-motion-corrected optical coherence tomography angiography using Lissajous scanning.

    PubMed

    Chen, Yiwei; Hong, Young-Joo; Makita, Shuichi; Yasuno, Yoshiaki

    2018-03-01

    To correct eye motion artifacts in en face optical coherence tomography angiography (OCT-A) images, a Lissajous scanning method with subsequent software-based motion correction is proposed. The standard Lissajous scanning pattern is modified to be compatible with OCT-A and a corresponding motion correction algorithm is designed. The effectiveness of our method was demonstrated by comparing en face OCT-A images with and without motion correction. The method was further validated by comparing motion-corrected images with scanning laser ophthalmoscopy images, and the repeatability of the method was evaluated using a checkerboard image. A motion-corrected en face OCT-A image from a blinking case is presented to demonstrate the ability of the method to deal with eye blinking. Results show that the method can produce accurate motion-free en face OCT-A images of the posterior segment of the eye in vivo .

  8. Overcoming Presbyopia by Manipulating the Eyes' Optics

    NASA Astrophysics Data System (ADS)

    Zheleznyak, Leonard A.

    Presbyopia, the age-related loss of accommodation, is a visual condition affecting all adults over the age of 45 years. In presbyopia, individuals lose the ability to focus on nearby objects, due to a lifelong growth and stiffening of the eye's crystalline lens. This leads to poor near visual performance and affects patients' quality of life. The objective of this thesis is aimed towards the correction of presbyopia and can be divided into four aims. First, we examined the characteristics and limitations of currently available strategies for the correction of presbyopia. A natural-view wavefront sensor was used to objectively measure the accommodative ability of patients implanted with an accommodative intraocular lens (IOL). Although these patients had little accommodative ability based on changes in power, pupil miosis and higher order aberrations led to an improvement in through-focus retinal image quality in some cases. To quantify the through-focus retinal image quality of accommodative and multifocal IOLs directly, an adaptive optics (AO) IOL metrology system was developed. Using this system, the impact of corneal aberrations in regard to presbyopia-correcting IOLs was assessed, providing an objective measure of through-focus retinal image quality and practical guidelines for patient selection. To improve upon existing multifocal designs, we investigated retinal image quality metrics for the prediction of through-focus visual performance. The preferred metric was based on the fidelity of an image convolved with an aberrated point spread function. Using this metric, we investigated the potential of higher order aberrations and pupil amplitude apodization to increase the depth of focus of the presbyopic eye. Thirdly, we investigated modified monovision, a novel binocular approach to presbyopia correction using a binocular AO vision simulator. In modified monovision, different magnitudes of defocus and spherical aberration are introduced to each eye, thereby

  9. The Charles F. Prentice Award Lecture 2005: optics of the human eye: progress and problems.

    PubMed

    Charman, W Neil

    2006-06-01

    The history of measurements of ocular aberration is briefly reviewed and recent work using much-improved aberrometers and large samples of eyes is summarized. When on-axis, higher-order, monochromatic aberrations are averaged, undercorrected, positive, fourth-order spherical aberration dominates; other Zernike wavefront aberration coefficients have average values near zero. Individually, however, many eyes show substantial amounts of third-order and other fourth-order aberrations; the value of these varies idiosyncratically about zero. Most normal eyes show only small amounts of axial monochromatic aberration for photopic pupils up to around 3 mm; the limits to retinal image quality are then usually set by diffraction, uncorrected or imperfectly corrected spherocylindrical refractive error, accommodation error, and chromatic aberration. Longitudinal chromatic aberration varies very little across the population. With larger mesopic and scotopic pupils, monochromatic aberration plays a more important optical role, but overall visual performance is increasingly dominated by neural factors. Some remaining problems in measuring and modeling the eye's optical performance are discussed.

  10. 'Naked' radiopharmaceuticals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallner, Paul E.

    The term 'naked' radiopharmaceuticals, more appropriately, 'unbound' radiopharmaceuticals, refers to any radioisotope used for clinical research or clinical purposes that is not attached to a chemical or biological carrier, and that localizes in various tissues because of a physiologic or chemical propensity/affinity, or secondary to focal anatomic placement. Although they remain useful in selected clinical circumstances, the available agents (except for Iodine-131) have been relegated to an unfortunate and somewhat secondary role. The agents remain useful and worthy of consideration for new clinical investigation and clinical use.

  11. Correlation of individual cosmic ray nuclei with the observation of light flashes by Apollo astronauts. [nuclear emulsion detector design and operation

    NASA Technical Reports Server (NTRS)

    Pinsky, L. S.; Osborne, W. Z.; Bailey, J. V.

    1975-01-01

    A nuclear emulsion detector known as the Apollo Light Flash Moving Emulsion Detector (ALFMED) was designed: (1) to record tracks of primary cosmic rays; (2) to provide time-of-passage information via a relative plate translation technique; (3) to provide particle trajectory information; and (4) to fit into a masklike device that could be located about the head and eyes of an astronaut. An ALFMED device was worn by an astronaut observing light flashes for 60 minutes on each of the last two Apollo missions. During the Apollo 17 experiment seventeen separate flashes were reported by the observer. With one-third of the total plate area completely analyzed, two definite correlations have been found between Z greater than 8 cosmic ray nuclei traversing an eye and the reports of visual sensations.

  12. Anatomy of the eye from the view of Ibn Al-Haitham (965-1039). The founder of modern optics.

    PubMed

    Unal, Nedim; Elcioglu, Omur

    2009-03-01

    Ibn Al-Haitham (known as Alhazen in Latin [965 Basra, Iraq-1039, Cairo, Egypt]) was a scientist who played an important role in the middle age Islam world. He wrote many books and novels, but only 90 of them are known. His main book Kitab al-Manazir was translated into Western languages in the late twelfth century, and in the early thirteenth century. In this book, he formulated many hypotheses on optical science. The book, which is also known as Optic treasure (opticae thesaurus), affected many famous Western scientists. He became an authority until the seventeenth century in the Eastern and Western countries. Roger Bacon (1212-1294), who made radical changes in the Western optical traditions, reconfirmed Ibn Al-Haitham's findings. Ibn al-Haitham began his book Kitab al-Manazir with the anatomy and physiology of the eye. He specifically described cornea, humor aqueous, lens, and corpus vitreum. He examined the effect of light on seeing. He caused changes in the prevailing ideas of his age, and suggested that light came from objects, not from the eye. He provided information regarding the optic nerve, retina, iris, and conjunctiva. He showed the system of the eye as a dioptric, and the relations between the parts of the eye. It is understood that he mastered all knowledge on the structure of the eye in his century. The best proof of this is the eye picture that he drew.

  13. Visual Discomfort From Flash Afterimages of Riloid Patterns.

    PubMed

    O'Hare, Louise

    2017-06-01

    Op-art-based stimuli have been shown to be uncomfortable, possibly due to a combination of fixational eye movements (microsaccades) and excessive cortical responses. Efforts have been made to measure illusory phenomena arising from these stimuli in the absence of microsaccades, but there has been no attempt thus far to decouple the effects of the cortical response from the effect of fixational eye movements. This study uses flash afterimages to stabilise the image on the retina and thus reduce the systematic effect of eye movements, in order to investigate the role of the brain in discomfort from op-art-based stimuli. There was a relationship between spatial frequency and the magnitude of the P300 response, showing a similar pattern to that of discomfort judgements, which suggests that there might be a role of discomfort and excessive neural responses independently from the effects of microsaccades.

  14. High-resolution imaging of the retinal nerve fiber layer in normal eyes using adaptive optics scanning laser ophthalmoscopy.

    PubMed

    Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Arakawa, Naoko; Oshima, Susumu; Shibata, Naohisa; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa

    2012-01-01

    To conduct high-resolution imaging of the retinal nerve fiber layer (RNFL) in normal eyes using adaptive optics scanning laser ophthalmoscopy (AO-SLO). AO-SLO images were obtained in 20 normal eyes at multiple locations in the posterior polar area and a circular path with a 3-4-mm diameter around the optic disc. For each eye, images focused on the RNFL were recorded and a montage of AO-SLO images was created. AO-SLO images for all eyes showed many hyperreflective bundles in the RNFL. Hyperreflective bundles above or below the fovea were seen in an arch from the temporal periphery on either side of a horizontal dividing line to the optic disc. The dark lines among the hyperreflective bundles were narrower around the optic disc compared with those in the temporal raphe. The hyperreflective bundles corresponded with the direction of the striations on SLO red-free images. The resolution and contrast of the bundles were much higher in AO-SLO images than in red-free fundus photography or SLO red-free images. The mean hyperreflective bundle width around the optic disc had a double-humped shape; the bundles at the temporal and nasal sides of the optic disc were narrower than those above and below the optic disc (P<0.001). RNFL thickness obtained by optical coherence tomography correlated with the hyperreflective bundle widths on AO-SLO (P<0.001) AO-SLO revealed hyperreflective bundles and dark lines in the RNFL, believed to be retinal nerve fiber bundles and Müller cell septa. The widths of the nerve fiber bundles appear to be proportional to the RNFL thickness at equivalent distances from the optic disc.

  15. Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies.

    PubMed

    Nowinska, Anna K; Teper, Sławomir J; Janiszewska, Dominika A; Lyssek-Boron, Anita; Dobrowolski, Dariusz; Koprowski, Robert; Wylegala, Edward

    2015-01-01

    To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.

  16. Hot Flashes

    MedlinePlus

    ... report menopausal hot flashes than do women of European descent. Hot flashes are less common in women of Japanese and Chinese descent than in white European women. Complications Nighttime hot flashes (night sweats) can ...

  17. Multi-contrast imaging of human posterior eye by Jones matrix optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Yasuno, Yoshiaki

    2017-04-01

    A multi-contrast imaging of pathologic posterior eyes is demonstrated by Jones matrix optical coherence tomography (Jones matrix OCT). The Jones matrix OCT provides five tomographies, which includes scattering, local attenuation, birefringence, polarization uniformity, and optical coherence angiography, by a single scan. The hardware configuration, algorithms of the Jones matrix OCT as well as its application to ophthalmology is discussed.

  18. Effect of diquafosol ophthalmic solution on the optical quality of the eyes in patients with aqueous-deficient dry eye.

    PubMed

    Koh, Shizuka; Maeda, Naoyuki; Ikeda, Chikako; Oie, Yoshinori; Soma, Takeshi; Tsujikawa, Motokazu; Watanabe, Hitoshi; Nishida, Kohji

    2014-12-01

    To investigate the short- and long-term effects of diquafosol ophthalmic solution on the optical quality of the eyes in patients with aqueous-deficient dry eye. Sixteen eyes in 16 patients with mild or moderate aqueous-deficient dry eye were treated with 3% diquafosol ophthalmic solution. Ocular higher-order aberrations (HOAs) were measured with a wavefront sensor before and at 15 min after diquafosol instillation at the baseline visit and at 4 weeks after treatment initiation. Dry eye symptoms, tear break-up time (BUT), corneal/conjunctival fluorescein staining and Schirmer's test were also evaluated before and after treatment with diquafosol. Treatment with diquafosol ophthalmic solution significantly improved dry eye symptoms, corneal staining and BUT. Compared with mean total HOAs at baseline (0.180 ± 0.06 μm), those at 4 weeks after treatment significantly decreased (0.148 ± 0.039 μm; p = 0.035), whereas those 15 min after diquafosol instillation at the baseline visit did not change significantly (0.170 ± 0.049 μm; p = 0.279). Although no significant change in HOAs was observed as a short-term effect of a single-drop instillation of diquafosol, long-term use of diquafosol to treat aqueous-deficient dry eye reduced HOAs as well as improved corneal epithelial damage and tear film stability. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  19. Light Flashes Observed by Astronauts on Apollo 11 through Apollo 17.

    PubMed

    Pinsky, L S; Osborne, W Z; Bailey, J V; Benson, R E; Thompson, L F

    1974-03-08

    The crew members on the last seven Apollo flights observed light flashes that are tentatively attributed to cosmic ray nuclei (atomic number >/= 6) penetrating the head and eyes of the observers. Analyses of the event rates for all missions has revealed an anomalously low rate for transearth coast observations with respect to translunar coast observations.

  20. The fascinating early history of optics! Archaeological optics 2009: our knowledge of the early history of lenses, mirrors, and artificial eyes!

    NASA Astrophysics Data System (ADS)

    Enoch, Jay M.

    2009-08-01

    The early history of optics and vision science (older term: physiological optics) is indeed fascinating. The earliest known true lenses have been found in "eyes" of Egyptian statues which contain superb, complex, and well-polished eye-lens units. The oldest ones known are dated circa 2575 BCE = BC, Dynasty IV, Old Kingdom. These eye-lens units induce a fascinating and powerful visual illusion, but they are just too good to have been the first lenses, or even the first lenses of this design! So saying, no earlier dateable lenses have been found in Egypt or elsewhere. Recently, at the Boston Museum of Fine Arts, the writer noted a previously undetected lens in this series (a first in the Western Hemisphere). Oddly, dateable simpler magnifying lenses and burning glasses seem to have appeared later in time (?)! Manufactured mirrors are quite a bit older, dating from circa 6000 BCE in atal Hyk, located in south-central modern-day Turkey. Using these ancient mirrors, the image quality obtained is remarkable! Recently discovered ancient artificial eyes, located, in situ, in exhumed corpses, have been dated circa 3000 BCE (one discovered in Iran) 5000 BCE (one found in Spain). On the 3000 BCE artificial eye, there are drawn light rays (the writer believes these to be the oldest known depiction of light rays!) spreading out from (or passing into) the iris/ pupil border! Added interesting aspects associated with the early development of light-rays are considered. Thus, early optics can be readily traced back to the Neolithic era (the new stone age), and in some cases before that time period. We have deep roots indeed!

  1. Laser head for simultaneous optical pumping of several dye lasers. [with single flash lamp

    NASA Technical Reports Server (NTRS)

    Mumola, P. B.; Mcalexander, B. T. (Inventor)

    1975-01-01

    The invention is a laser head for simultaneous pumping several dye lasers with a single flash lamp. The laser head includes primarily a multi-elliptical cylinder cavity with a single flash lamp placed along the common focal axis of the cavity and with capillary tube dye cells placed along each of the other focal axes of the cavity. The inside surface of the cavity is polished. Hence, the single flash lamp supplies the energy to the several dye cells.

  2. Comparison of optic disc topography in non-glaucomatous eyes of children with juvenile diabetes mellitus and normal children.

    PubMed

    Elgin, Ufuk; Cankaya, Bülent; Simsek, Tulay; Batman, Aygen

    2010-01-01

    To compare the optic disc topography parameters of children with juvenile diabetes mellitus and normal children using the Heidelberg Retinal Tomograph (HRT III) (Heidelberg Engineering, Heidelberg, Germany). The topographic optic disc parameters (cup volume, cup area, rim volume, rim area, disc area, mean cup-to-disc ratio, and mean cup depth) of 28 non-glaucomatous eyes of 28 children with type 1 diabetes mellitus and 28 eyes of 28 age-matched healthy children were compared using the nonparametric Mann-Whitney U test. No statistically significant differences were found between cup volume (P = .782), cup area (P = .878), rim volume (P = .853), disc area (P = .452), mean cup-to-disc ratio (P = .852), and mean cup depth (P = .711) of eyes of cases with diabetes mellitus and normal subjects. This result suggests that non-glaucomatous eyes of children with type 1 diabetes mellitus and healthy subjects have similar topographic optic disc characteristics. Copyright 2010, SLACK Incorporated.

  3. Comparison of Optical versus Ultrasonic Biometry in Keratoconic Eyes

    PubMed Central

    Çınar, Yasin; Cingü, Abdullah Kürşat; Şahin, Muhammed; Yüksel, Harun; Türkcü, Fatih Mehmet; Çınar, Tuba; Çaça, İhsan

    2013-01-01

    Purpose. To compare the measurements of optical versus ultrasonic biometry devices in keratoconic eyes. Materials and Methods. Forty-two eyes of 42 keratoconus (KC) patients enrolled in the study were examined. Clinical and demographic characteristics of the patients were noted, and detailed ophthalmological examination was performed. Following Pentacam measurements, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were obtained using the Lenstar and US biometer to determine the reproducibility of the measurements between the two devices in keratoconic eyes. The Bland-Altman method was used to describe the agreement between the two devices. Results. The Lenstar could not measure at least one of the biometric properties in one eye and did not automatically give the corrected ACD in 2/3 of our study population. The Lenstar measured CCT (average difference 5.4 ± 19.6 µm; ICC = 0.90; P < 0.001), LT (average difference 0.13 ± 0.17 mm; ICC = 0.67; P < 0.001), and AL (average difference 0.10 ± 0.76 mm; ICC = 0.75; P < 0.001) thinner than US biometer, whereas it measured ACD (average difference 0.18 ± 0.17 mm; ICC = 0.85; P < 0.001) deeper than US biometer in keratoconic eyes. Conclusion. Although the difference between the measurements obtained using the two devices might be clinically acceptable, US biometry and Lenstar should not be used interchangeably for biometric measurements in KC patients. PMID:23986865

  4. Comparison of Optical versus Ultrasonic Biometry in Keratoconic Eyes.

    PubMed

    Cınar, Yasin; Cingü, Abdullah Kürşat; Sahin, Muhammed; Sahin, Alparslan; Yüksel, Harun; Türkcü, Fatih Mehmet; Cınar, Tuba; Caça, Ihsan

    2013-01-01

    Purpose. To compare the measurements of optical versus ultrasonic biometry devices in keratoconic eyes. Materials and Methods. Forty-two eyes of 42 keratoconus (KC) patients enrolled in the study were examined. Clinical and demographic characteristics of the patients were noted, and detailed ophthalmological examination was performed. Following Pentacam measurements, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were obtained using the Lenstar and US biometer to determine the reproducibility of the measurements between the two devices in keratoconic eyes. The Bland-Altman method was used to describe the agreement between the two devices. Results. The Lenstar could not measure at least one of the biometric properties in one eye and did not automatically give the corrected ACD in 2/3 of our study population. The Lenstar measured CCT (average difference 5.4 ± 19.6 µm; ICC = 0.90; P < 0.001), LT (average difference 0.13 ± 0.17 mm; ICC = 0.67; P < 0.001), and AL (average difference 0.10 ± 0.76 mm; ICC = 0.75; P < 0.001) thinner than US biometer, whereas it measured ACD (average difference 0.18 ± 0.17 mm; ICC = 0.85; P < 0.001) deeper than US biometer in keratoconic eyes. Conclusion. Although the difference between the measurements obtained using the two devices might be clinically acceptable, US biometry and Lenstar should not be used interchangeably for biometric measurements in KC patients.

  5. Modern optics in exceptionally preserved eyes of Early Cambrian arthropods from Australia

    NASA Astrophysics Data System (ADS)

    Lee, Michael S. Y.; Jago, James B.; García-Bellido, Diego C.; Edgecombe, Gregory D.; Gehling, James G.; Paterson, John R.

    2011-06-01

    Despite the status of the eye as an ``organ of extreme perfection'', theory suggests that complex eyes can evolve very rapidly. The fossil record has, until now, been inadequate in providing insight into the early evolution of eyes during the initial radiation of many animal groups known as the Cambrian explosion. This is surprising because Cambrian Burgess-Shale-type deposits are replete with exquisitely preserved animals, especially arthropods, that possess eyes. However, with the exception of biomineralized trilobite eyes, virtually nothing is known about the details of their optical design. Here we report exceptionally preserved fossil eyes from the Early Cambrian (~515 million years ago) Emu Bay Shale of South Australia, revealing that some of the earliest arthropods possessed highly advanced compound eyes, each with over 3,000 large ommatidial lenses and a specialized `bright zone'. These are the oldest non-biomineralized eyes known in such detail, with preservation quality exceeding that found in the Burgess Shale and Chengjiang deposits. Non-biomineralized eyes of similar complexity are otherwise unknown until about 85 million years later. The arrangement and size of the lenses indicate that these eyes belonged to an active predator that was capable of seeing in low light. The eyes are more complex than those known from contemporaneous trilobites and are as advanced as those of many living forms. They provide further evidence that the Cambrian explosion involved rapid innovation in fine-scale anatomy as well as gross morphology, and are consistent with the concept that the development of advanced vision helped to drive this great evolutionary event.

  6. Microfabricated ommatidia using a laser induced self-writing process for high resolution artificial compound eye optical systems.

    PubMed

    Jung, Hyukjin; Jeong, Ki-Hun

    2009-08-17

    A microfabricated compound eye, comparable to a natural compound eye shows a spherical arrangement of integrated optical units called artificial ommatidia. Each consists of a self-aligned microlens and waveguide. The increase of waveguide length is imperative to obtain high resolution images through an artificial compound eye for wide field-of - view imaging as well as fast motion detection. This work presents an effective method for increasing the waveguide length of artificial ommatidium using a laser induced self-writing process in a photosensitive polymer resin. The numerical and experimental results show the uniform formation of waveguides and the increment of waveguide length over 850 microm. (c) 2009 Optical Society of America

  7. Saccade Modulation by Optical and Electrical Stimulation in the Macaque Frontal Eye Field

    PubMed Central

    Grimaldi, Piercesare; Schweers, Nicole

    2013-01-01

    Recent studies have demonstrated that strong neural modulations can be evoked with optogenetic stimulation in macaque motor cortex without observing any evoked movements (Han et al., 2009, 2011; Diester et al., 2011). It remains unclear why such perturbations do not generate movements and if conditions exist under which they may evoke movements. In this study, we examine the effects of five optogenetic constructs in the macaque frontal eye field and use electrical microstimulation to assess whether optical perturbation of the local network leads to observable motor changes during optical, electrical, and combined stimulation. We report a significant increase in the probability of evoking saccadic eye movements when low current electrical stimulation is coupled to optical stimulation compared with when electrical stimulation is used alone. Experiments combining channelrhodopsin 2 (ChR2) and electrical stimulation with simultaneous fMRI revealed no discernible fMRI activity at the electrode tip with optical stimulation but strong activity with electrical stimulation. Our findings suggest that stimulation with current ChR2 optogenetic constructs generates subthreshold activity that contributes to the initiation of movements but, in most cases, is not sufficient to evoke a motor response. PMID:24133271

  8. Quantitative analysis of eyes and other optical systems in linear optics.

    PubMed

    Harris, William F; Evans, Tanya; van Gool, Radboud D

    2017-05-01

    To show that 14-dimensional spaces of augmented point P and angle Q characteristics, matrices obtained from the ray transference, are suitable for quantitative analysis although only the latter define an inner-product space and only on it can one define distances and angles. The paper examines the nature of the spaces and their relationships to other spaces including symmetric dioptric power space. The paper makes use of linear optics, a three-dimensional generalization of Gaussian optics. Symmetric 2 × 2 dioptric power matrices F define a three-dimensional inner-product space which provides a sound basis for quantitative analysis (calculation of changes, arithmetic means, etc.) of refractive errors and thin systems. For general systems the optical character is defined by the dimensionally-heterogeneous 4 × 4 symplectic matrix S, the transference, or if explicit allowance is made for heterocentricity, the 5 × 5 augmented symplectic matrix T. Ordinary quantitative analysis cannot be performed on them because matrices of neither of these types constitute vector spaces. Suitable transformations have been proposed but because the transforms are dimensionally heterogeneous the spaces are not naturally inner-product spaces. The paper obtains 14-dimensional spaces of augmented point P and angle Q characteristics. The 14-dimensional space defined by the augmented angle characteristics Q is dimensionally homogenous and an inner-product space. A 10-dimensional subspace of the space of augmented point characteristics P is also an inner-product space. The spaces are suitable for quantitative analysis of the optical character of eyes and many other systems. Distances and angles can be defined in the inner-product spaces. The optical systems may have multiple separated astigmatic and decentred refracting elements. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  9. Periastron shift for a spinning test particle around naked singularities

    NASA Astrophysics Data System (ADS)

    Mukherjee, Sajal

    2018-06-01

    In the present article, we investigate the Periastron precession for a spinning test particle moving in nearly circular orbits around naked singularities. We consider two well-known solutions that can produce a spacetime with naked singularity—(a) first, the Reissner-Nordström metric, which is a static charged solution with spherical symmetry, and (b) second, the stationary, axisymmetric Kerr metric. For simplicity, we only consider the motion confined on the equatorial plane in both these cases and solve exactly the Mathisson-Papapetrou equations. In addition, we analytically compute the Periastron precession within the framework of linear spin approximation. The inclusion of the spin parameter modifies the results with nonspinning particles and also reflects some interesting properties of the naked geometries. Furthermore, we carried out a numerical approach without any assumptions to probe the large order spin values. The implication of the spin-curvature coupling in connection with the naked geometries is also discussed.

  10. Optic nerve head component responses of the multifocal electroretinogram in MS.

    PubMed

    Frohman, Teresa C; Beh, Shin Chien; Saidha, Shiv; Schnurman, Zane; Conger, Darrel; Conger, Amy; Ratchford, John N; Lopez, Carmen; Galetta, Steven L; Calabresi, Peter A; Balcer, Laura J; Green, Ari J; Frohman, Elliot M

    2013-08-06

    To employ a novel stimulation paradigm in order to elicit multifocal electroretinography (mfERG)-induced optic nerve head component (ONHC) responses, believed to be contingent upon the transformation in electrical transmission properties of retinal ganglion cell axons from membrane to saltatory conduction mechanisms, as they traverse the lamina cribrosa and obtain oligodendrocyte myelin. We further sought to characterize abnormalities in ONHC responses in eyes from patients with multiple sclerosis (MS). In 10 normal subjects and 7 patients with MS (including eyes with and without a history of acute optic neuritis), we utilized a novel mfERG stimulation paradigm that included interleaved global flashes in order to elicit the ONHC responses from 103 retinal patches of pattern-reversal stimulation. The number of abnormal or absent ONHC responses was significantly increased in MS patient eyes compared to normal subject eyes (p < 0.001, by general estimating equation modeling, and accounting for age and within-subject, intereye correlations). Studying the relationship between ONHC abnormalities and alterations in validated structural and functional measures of the visual system may facilitate the ability to dissect and characterize the pathobiological mechanisms that contribute to tissue damage in MS, and may have utility to detect and monitor neuroprotective or restorative effects of novel therapies.

  11. Marangoni Flowers and the Evil Eye: Overhead Presentations of Marangoni Flow

    ERIC Educational Resources Information Center

    Mundell, Donald W.

    2009-01-01

    Intermolecular forces and surface tension gradients in solutions lead to remarkable flows, known as Marangoni flows, where liquid flows from a region of low surface tension towards higher surface tension. Details of these flows, not visible to the naked eye, are made visible on an overhead projector owing to variation in the index of refraction.…

  12. Fly's Eye camera system: optical imaging using a hexapod platform

    NASA Astrophysics Data System (ADS)

    Jaskó, Attila; Pál, András.; Vida, Krisztián.; Mészáros, László; Csépány, Gergely; Mező, György

    2014-07-01

    The Fly's Eye Project is a high resolution, high coverage time-domain survey in multiple optical passbands: our goal is to cover the entire visible sky above the 30° horizontal altitude with a cadence of ~3 min. Imaging is going to be performed by 19 wide-field cameras mounted on a hexapod platform resembling a fly's eye. Using a hexapod developed and built by our team allows us to create a highly fault-tolerant instrument that uses the sky as a reference to define its own tracking motion. The virtual axis of the platform is automatically aligned with the Earth's rotational axis; therefore the same mechanics can be used independently from the geographical location of the device. Its enclosure makes it capable of autonomous observing and withstanding harsh environmental conditions. We briefly introduce the electrical, mechanical and optical design concepts of the instrument and summarize our early results, focusing on sidereal tracking. Due to the hexapod design and hence the construction is independent from the actual location, it is considerably easier to build, install and operate a network of such devices around the world.

  13. Forward light scatter analysis of the eye in a spatially-resolved double-pass optical system.

    PubMed

    Nam, Jayoung; Thibos, Larry N; Bradley, Arthur; Himebaugh, Nikole; Liu, Haixia

    2011-04-11

    An optical analysis is developed to separate forward light scatter of the human eye from the conventional wavefront aberrations in a double pass optical system. To quantify the separate contributions made by these micro- and macro-aberrations, respectively, to the spot image blur in the Shark-Hartmann aberrometer, we develop a metric called radial variance for spot blur. We prove an additivity property for radial variance that allows us to distinguish between spot blurs from macro-aberrations and micro-aberrations. When the method is applied to tear break-up in the human eye, we find that micro-aberrations in the second pass accounts for about 87% of the double pass image blur in the Shack-Hartmann wavefront aberrometer under our experimental conditions. © 2011 Optical Society of America

  14. Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies

    PubMed Central

    Teper, Sławomir J.; Janiszewska, Dominika A.; Lyssek-Boron, Anita; Dobrowolski, Dariusz; Koprowski, Robert; Wylegala, Edward

    2015-01-01

    Purpose. To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Methods. Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Results. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Conclusions. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements. PMID:26457303

  15. Enhanced neural function in highly aberrated eyes following perceptual learning with adaptive optics.

    PubMed

    Sabesan, Ramkumar; Barbot, Antoine; Yoon, Geunyoung

    2017-03-01

    Highly aberrated keratoconic (KC) eyes do not elicit the expected visual advantage from customized optical corrections. This is attributed to the neural insensitivity arising from chronic visual experience with poor retinal image quality, dominated by low spatial frequencies. The goal of this study was to investigate if targeted perceptual learning with adaptive optics (AO) can stimulate neural plasticity in these highly aberrated eyes. The worse eye of 2 KC subjects was trained in a contrast threshold test under AO correction. Prior to training, tumbling 'E' visual acuity and contrast sensitivity at 4, 8, 12, 16, 20, 24 and 28 c/deg were measured in both the trained and untrained eyes of each subject with their routine prescription and with AO correction for a 6mm pupil. The high spatial frequency requiring 50% contrast for detection with AO correction was picked as the training frequency. Subjects were required to train on a contrast detection test with AO correction for 1h for 5 consecutive days. During each training session, threshold contrast measurement at the training frequency with AO was conducted. Pre-training measures were repeated after the 5 training sessions in both eyes (i.e., post-training). After training, contrast sensitivity under AO correction improved on average across spatial frequency by a factor of 1.91 (range: 1.77-2.04) and 1.75 (1.22-2.34) for the two subjects. This improvement in contrast sensitivity transferred to visual acuity with the two subjects improving by 1.5 and 1.3 lines respectively with AO following training. One of the two subjects denoted an interocular transfer of training and an improvement in performance with their routine prescription post-training. This training-induced visual benefit demonstrates the potential of AO as a tool for neural rehabilitation in patients with abnormal corneas. Moreover, it reveals a sufficient degree of neural plasticity in normally developed adults who have a long history of abnormal visual

  16. ASSOCIATIONS BETWEEN MACULAR EDEMA AND CIRCULATORY STATUS IN EYES WITH RETINAL VEIN OCCLUSION: An Adaptive Optics Scanning Laser Ophthalmoscopy Study.

    PubMed

    Iida, Yuto; Muraoka, Yuki; Uji, Akihito; Ooto, Sotaro; Murakami, Tomoaki; Suzuma, Kiyoshi; Tsujikawa, Akitaka; Arichika, Shigeta; Takahashi, Ayako; Miwa, Yuko; Yoshimura, Nagahisa

    2017-10-01

    To investigate associations between parafoveal microcirculatory status and foveal pathomorphology in eyes with macular edema (ME) secondary to retinal vein occlusion (RVO). Ten consecutive patients (10 eyes) with acute retinal vein occlusion were enrolled, 9 eyes of which received intravitreal ranibizumab (IVR) injections. Foveal morphologic changes were examined via optical coherence tomography (OCT), and parafoveal circulatory status was assessed via adaptive optics scanning laser ophthalmoscopy (AO-SLO). The mean parafoveal aggregated erythrocyte velocity (AEV) measured by adaptive optics scanning laser ophthalmoscopy in eyes with retinal vein occlusion was 0.99 ± 0.43 mm/second at baseline, which was significantly lower than that of age-matched healthy subjects (1.41 ± 0.28 mm/second, P = 0.042). The longitudinal adaptive optics scanning laser ophthalmoscopy examinations of each patient showed that parafoveal AEV was strongly inversely correlated with optical coherence tomography-measured central foveal thickness (CFT) over the entire observation period. Using parafoveal AEV and central foveal thickness measurements obtained at the first and second examinations, we investigated associations between differences in parafoveal AEV and central foveal thickness, which were significantly and highly correlated (r = -0.84, P = 0.002). Using adaptive optics scanning laser ophthalmoscopy in eyes with retinal vein occlusion macular edema, we could quantitatively evaluate the parafoveal AEV. A reduction or an increase in parafoveal AEV may be a clinical marker for the resolution or development/progression of macular edema respectively.

  17. A simple, reversible, colorimetric and water-soluble fluorescent chemosensor for the naked-eye detection of Cu2+ in ~100% aqueous media and application to real samples.

    PubMed

    Sun, Tao; Niu, Qingfen; Li, Tianduo; Guo, Zongrang; Liu, Haixia

    2018-01-05

    A simple, reversible, colorimetric and water-soluble fluorescent chemosensor ADA for the naked-eye detection of Cu 2+ was developed. Sensor ADA showed high selectivity and sensitivity toward Cu 2+ in ~100% aqueous media over wide pH range. Sensor ADA exhibited a red-shift in the absorption spectra from 466 to 480nm that is accompanied by significant color change from light yellow to yellowish brown instantaneously. The Cu 2+ recognition is based on the chelation-enhanced fluorescence quenching (CHEQ) effect of the paramagnetic nature. The lowest detection limit is determined to be 15.8nM, which is much lower than the allowable level of Cu 2+ in drinking water set by U.S. Environmental Protection Agency (~20μM) and the World Health Organization (~30μM). The 1:1 binding process was confirmed by fluorescence measurements, IR analysis and DFT studies. Moreover, sensor ADA was successfully applied for determination of trace level of Cu 2+ with 4 reuse cycles in various water samples, which affords promising potential in ion-detection field. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Epidemic optic neuropathy in Cuba. Eye findings.

    PubMed

    Sadun, A A; Martone, J F; Muci-Mendoza, R; Reyes, L; DuBois, L; Silva, J C; Roman, G; Caballero, B

    1994-05-01

    To characterize and establish a clinical definition of the optic neuropathy that appeared in epidemic form in Cuba in 1992 and 1993. At the invitation of the Cuban Ministry of Health, Havana, members of ORBIS International and the Pan American Health Organization, assembled teams that traveled to Cuba in May 1993. We were initially briefed by Cuban national experts in the areas of virology, nutrition, toxicology, ophthalmology, neurology, and public health. We then examined 20 patients on our own. Thirteen of these patients underwent a comprehensive neuro-ophthalmologic examination, including neurologic examination, ophthalmologic examination, visual fields, optic nerve function studies, contrast sensitivity studies, and funduscopy. We returned 4 months later to perform an additional 12 comprehensive neuro-ophthalmologic and follow-up examinations. Only seven of the 13 patients who were alleged to have the optic form of the epidemic and who were rigorously and systematically examined on the first visit demonstrated a bilateral optic neuropathy. These seven patients had several features that included decreased visual acuity, poor color vision, central scotomas, decreased contrast sensitivity, saccadic eye movements, and most prominent and distinctive of all, nerve fiber layer wedge defects of the papillomacular bundle. Our clinical definition was then implemented by the Cuban ophthalmologists and epidemiologists. On returning 4 months later, we found that all newly presented patients were correctly diagnosed to have the epidemic disease. With the new case definition and the application of a few simple psychophysical tests, the false-positive rate of diagnosis became much lower. After vitamin therapy, we reexamined the patients seen on our initial visit, and all showed marked improvement. The Cuban epidemic was characterized by an optic neuropathy with features that were similar to those of tobacco/alcohol amblyopia and Leber's optic atrophy. Recent political

  19. Sustainable Utilization of Bio waste towards the Green Synthesis of Nanoparticles and its Utility in the Naked Eye Detection of Metals Coupled with its Larvicidal and Antimicrobial Properties

    NASA Astrophysics Data System (ADS)

    Nikhila, P. S.; Satheesh, Namitha; Sreejitha, V. S.; Pillai, Anandu R.; Saritha, A.; Smitha Chandran, S.

    2018-02-01

    Green synthesis of nanoparticles has become a prominent zone of attention in the field of nanotechnology, as it is a nontoxic, economically feasible and green approach. In the present work we have developed an eco-friendly and zero cost method for the synthesis of silver nanoparticles using common a bio waste banana blossom peel. The well-known characteristic phenomenon of surface Plasmon resonance (SPR) has been exploited towards the characterization of the green synthesized nanoparticles. The aforementioned nanoparticles were characterized by UV spectroscopy and the behaviour of these particles towards naked eye detection of metal ions were observed. The sensitivity of the nanoparticles towards the detection of metal ions was carefully monitored by the shift in the SPR band. Moreover the larvicidal potential of these green synthesized silver nanoparticles were evaluated as per WHO standards. The synthesized silver nanoparticles were found to be an effective antibacterial agent against Gram negative bacteria-E.coli. The method we followed for the synthesis of silver nanoparticles is economically feasible as well as environment friendly and also capable of rapid synthesis of nanoparticles at ambient conditions.

  20. Optical Coherence Tomography Angiography Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes

    PubMed Central

    Yarmohammadi, Adeleh; Zangwill, Linda M.; Diniz-Filho, Alberto; Suh, Min Hee; Manalastas, Patricia Isabel; Fatehee, Naeem; Yousefi, Siamak; Belghith, Akram; Saunders, Luke J.; Medeiros, Felipe A.; Huang, David; Weinreb, Robert N.

    2016-01-01

    Purpose The purpose of this study was to compare retinal nerve fiber layer (RNFL) thickness and optical coherence tomography angiography (OCT-A) retinal vasculature measurements in healthy, glaucoma suspect, and glaucoma patients. Methods Two hundred sixty-one eyes of 164 healthy, glaucoma suspect, and open-angle glaucoma (OAG) participants from the Diagnostic Innovations in Glaucoma Study with good quality OCT-A images were included. Retinal vasculature information was summarized as a vessel density map and as vessel density (%), which is the proportion of flowing vessel area over the total area evaluated. Two vessel density measurements extracted from the RNFL were analyzed: (1) circumpapillary vessel density (cpVD) measured in a 750-μm-wide elliptical annulus around the disc and (2) whole image vessel density (wiVD) measured over the entire image. Areas under the receiver operating characteristic curves (AUROC) were used to evaluate diagnostic accuracy. Results Age-adjusted mean vessel density was significantly lower in OAG eyes compared with glaucoma suspects and healthy eyes. (cpVD: 55.1 ± 7%, 60.3 ± 5%, and 64.2 ± 3%, respectively; P < 0.001; and wiVD: 46.2 ± 6%, 51.3 ± 5%, and 56.6 ± 3%, respectively; P < 0.001). For differentiating between glaucoma and healthy eyes, the age-adjusted AUROC was highest for wiVD (0.94), followed by RNFL thickness (0.92) and cpVD (0.83). The AUROCs for differentiating between healthy and glaucoma suspect eyes were highest for wiVD (0.70), followed by cpVD (0.65) and RNFL thickness (0.65). Conclusions Optical coherence tomography angiography vessel density had similar diagnostic accuracy to RNFL thickness measurements for differentiating between healthy and glaucoma eyes. These results suggest that OCT-A measurements reflect damage to tissues relevant to the pathophysiology of OAG. PMID:27409505

  1. Optical imaging through turbid media with a degenerate four-wave mixing correlation time gate

    DOEpatents

    Sappey, Andrew D.

    1998-04-14

    Optical imaging through turbid media is demonstrated using a degenerate four-wave mixing correlation time gate. An apparatus and method for detecting ballistic and/or snake light while rejecting unwanted diffusive light for imaging structures within highly scattering media are described. Degenerate four-wave mixing (DFWM) of a doubled YAG laser in rhodamine 590 is used to provide an ultrafast correlation time gate to discriminate against light that has undergone multiple scattering and therefore has lost memory of the structures within the scattering medium. Images have been obtained of a test cross-hair pattern through highly turbid suspensions of whole milk in water that are opaque to the naked eye, which demonstrates the utility of DFWM for imaging through turbid media. Use of DFWM as an ultrafast time gate for the detection of ballistic and/or snake light in optical mammography is discussed.

  2. Dynamic Imaging of the Eye, Optic Nerve, and Extraocular Muscles With Golden Angle Radial MRI

    PubMed Central

    Smith, David S.; Smith, Alex K.; Welch, E. Brian; Smith, Seth A.

    2017-01-01

    Purpose The eye and its accessory structures, the optic nerve and the extraocular muscles, form a complex dynamic system. In vivo magnetic resonance imaging (MRI) of this system in motion can have substantial benefits in understanding oculomotor functioning in health and disease, but has been restricted to date to imaging of static gazes only. The purpose of this work was to develop a technique to image the eye and its accessory visual structures in motion. Methods Dynamic imaging of the eye was developed on a 3-Tesla MRI scanner, based on a golden angle radial sequence that allows freely selectable frame-rate and temporal-span image reconstructions from the same acquired data set. Retrospective image reconstructions at a chosen frame rate of 57 ms per image yielded high-quality in vivo movies of various eye motion tasks performed in the scanner. Motion analysis was performed for a left–right version task where motion paths, lengths, and strains/globe angle of the medial and lateral extraocular muscles and the optic nerves were estimated. Results Offline image reconstructions resulted in dynamic images of bilateral visual structures of healthy adults in only ∼15-s imaging time. Qualitative and quantitative analyses of the motion enabled estimation of trajectories, lengths, and strains on the optic nerves and extraocular muscles at very high frame rates of ∼18 frames/s. Conclusions This work presents an MRI technique that enables high-frame-rate dynamic imaging of the eyes and orbital structures. The presented sequence has the potential to be used in furthering the understanding of oculomotor mechanics in vivo, both in health and disease. PMID:28813574

  3. AMISH EYE STUDY: Baseline Spectral Domain Optical Coherence Tomography Characteristics of Age-Related Macular Degeneration.

    PubMed

    Nittala, Muneeswar G; Song, Yeunjoo E; Sardell, Rebecca; Adams, Larry D; Pan, Samuel; Velaga, Swetha B; Horst, Violet; Dana, Debra; Caywood, Laura; Laux, Renee; Fuzzell, Denise; Fuzzell, Sarada; Scott, William K; Cooke Bailey, Jessica N; Igo, Robert P; Haines, Jonathan; Pericak-Vance, Margaret A; Sadda, SriniVas R; Stambolian, Dwight

    2018-05-09

    To describe spectral domain optical coherence tomography (SD-OCT) findings in an Amish cohort to assess SD-OCT markers for early age-related macular degeneration (AMD). The authors performed a family-based prospective cohort study of 1,146 elderly Amish subjects (age range 50-99 years) (2,292 eyes) who had a family history of at least 1 individual with AMD. All subjects underwent complete ophthalmic examinations, SD-OCT using both Cirrus and Spectralis (20 × 20° scan area) instruments, fundus autofluorescence, infrared imaging, and color fundus photography. Spectral domain optical coherence tomography characteristics were analyzed in subjects with AMD (with and without subretinal drusenoid deposits [SDDs]) and normal healthy cohorts. Participants' mean age was 65.2 years (SD ± 11). Color fundus photographic findings in 596 (53%) subjects (1,009 eyes) were consistent with AMD; the remaining 478 (43%) subjects showed no signs of AMD. The choroid was significantly thinner on OCT (242 ± 76 µm, P < 0.001) in those with AMD compared with those without (263 ± 63 µm). Subretinal drusenoid deposits were found in 143 eyes (7%); 11 of the 143 eyes (8%) had no other manifestations of AMD. Drusen volume (P < 0.001) and area of geographic atrophy (P < 0.001) were significantly greater, and choroid was significantly (P < 0.001) thinner in subjects with SDDs versus those without SDDs. The authors describe spectral domain optical coherence tomography characteristics in an elderly Amish population with and without AMD, including the frequency of SDD. Although relatively uncommon in this population, the authors confirmed that SDDs can be found in the absence of other features of AMD and that eyes with SDDs have thinner choroids.

  4. Optimal flash rate and duty cycle for flashing visual indicators.

    NASA Technical Reports Server (NTRS)

    Markowitz, J.

    1971-01-01

    This experiment examined the ability of observers to determine, as quickly as possible, whether a visual indicator was steadily on or flashing. Six flash rates (periods) were combined factorially with three duty cycles (on-off ratios) to define 18 ?types' of intermittent signals. Experimental sessions were divided into six runs of 100 trials, each run utilizing one of the six flash rates. On any given trial in a run, the probability of a steady signal occurring was 0.5 and the probability of a flashing signal occurring was 0.5. A different duty cycle was employed daily for each experimental session. In all, 400 trials were devoted to each of the flash rates at each duty cycle. Accuracy and latency of response were the dependent variables of interest. The results show that the observers view the light for an interval of time appropriate to the expected flash rate and duty cycle; whether they judge the light to be steady or intermittent depends upon whether the light is extinguished during the predetermined waiting period. Adoption of this temporal criterion delays responding in comparison to those tasks involving responses to light onset. The decision or response criteria held by the observers are also sensitive to the parameters of the flashing light: observers become increasingly willing to call a flashing light ?steady' as flash duration increases.

  5. Naked-eye point-of-care testing platform based on a pH-responsive superwetting surface: toward the non-invasive detection of glucose

    NASA Astrophysics Data System (ADS)

    Gao, Zhong Feng; Sann, Ei Ei; Lou, Xiaoding; Liu, Renyi; Dai, Jun; Zuo, Xiaolei; Xia, Fan; Jiang, Lei

    2018-04-01

    Herein, we demonstrate a contact angle (CA)-based naked-eye point-of-care testing platform with rapid pH-responsive superwettability that can switch between superhydrophilic and superhydrophobic properties for quantitative biosensing. The CA of the droplet on the pH-responsive surface approached 0° at pH 1 and conversely reached 161.4° ± 6.2° at pH 13. We realized the sensitive detection of the pH, urea, and glucose by monitoring the changes in the CA. The traditional invasive diagnosis of diabetes causes pain and brings the risk of infections, such as acquired immune deficiency syndrome (AIDS), hepatitis B, hepatitis C, and syphilis, to the user. To address this issue, we implemented a method for the non-invasive diagnosis of diabetes in human saliva and urine, which avoided the significant drawbacks mentioned above. The accuracy of this method was demonstrated by comparing the results with those from commercial glucometers and theoretical calculations. Interestingly, we successfully monitored glucose levels in sweat before, during, and after cycling. The sensing performance was barely influenced by the temperature, elevation, and droplet color, illustrating promise for expansion to hundreds of millions of potential customers, especially those with color blindness or color weakness. Given its low cost, lack of instruments, and rapid response (within 1 s), this strategy might overcome the limitations of the mechanical stability and durability of superwettable materials and thus might extend the industrial-scale application of bioinspired superwettable systems.

  6. Gun muzzle flash detection using a CMOS single photon avalanche diode

    NASA Astrophysics Data System (ADS)

    Merhav, Tomer; Savuskan, Vitali; Nemirovsky, Yael

    2013-10-01

    Si based sensors, in particular CMOS Image sensors, have revolutionized low cost imaging systems but to date have hardly been considered as possible candidates for gun muzzle flash detection, due to performance limitations, and low SNR in the visible spectrum. In this study, a CMOS Single Photon Avalanche Diode (SPAD) module is used to record and sample muzzle flash events in the visible spectrum, from representative weapons, common on the modern battlefield. SPADs possess two crucial properties for muzzle flash imaging - Namely, very high photon detection sensitivity, coupled with a unique ability to convert the optical signal to a digital signal at the source pixel, thus practically eliminating readout noise. This enables high sampling frequencies in the kilohertz range without SNR degradation, in contrast to regular CMOS image sensors. To date, the SPAD has not been utilized for flash detection in an uncontrolled environment, such as gun muzzle flash detection. Gun propellant manufacturers use alkali salts to suppress secondary flashes ignited during the muzzle flash event. Common alkali salts are compounds based on Potassium or Sodium, with spectral emission lines around 769nm and 589nm, respectively. A narrow band filter around the Potassium emission doublet is used in this study to favor the muzzle flash signal over solar radiation. This research will demonstrate the SPAD's ability to accurately sample and reconstruct the temporal behavior of the muzzle flash in the visible wavelength under the specified imaging conditions. The reconstructed signal is clearly distinguishable from background clutter, through exploitation of flash temporal characteristics.

  7. Using optical coherence tomography to evaluate glaucoma implant healing response in rabbit eyes

    NASA Astrophysics Data System (ADS)

    Gossage, Kirk W.; Tkaczyk, Tomasz S.; Barton, Jennifer K.

    2002-06-01

    Glaucoma is a set of diseases that cause optic nerve damage and visual field loss. The most important risk factor for the development of glaucoma is elevated intraocular pressure. One approach used to alleviate the pressure increase is to surgically install glaucoma implants. Two standard Ahmed and ten experimental ePTFE implants were evaluated in this study in rabbit eyes. The implants were imaged with optical coherence tomography (OCT) at 0, 7, 15, 30, and 90 days after implantation. Histology was collected at days 7, 15, 30, and 90 and compared to the OCT images. Preliminary analysis of images indicates that OCT can visualize the development of fibrous encapsulation of the implant, tissue erosion, fibrin accumulation in the implant tube, and tube position in the anterior chamber. A new OCT handheld probe was developed to facilitate in vivo imaging in rabbit eye studies. The OCT probe consists of a mechanical scaffold designed to allow the imaging fiber to be held in a fixed position with respect to the rabbit eye, with minimal anesthesia. A piezo electric lateral scanning device allows the imaging fiber to be scanned across the tissue so that 2D images may be acquired.

  8. Tests of the Grobner Basis Solution for Lightning Ground Flash Fraction Retrieval

    NASA Technical Reports Server (NTRS)

    Koshak, William; Solakiewicz, Richard; Attele, Rohan

    2011-01-01

    Satellite lightning imagers such as the NASA Tropical Rainfall Measuring Mission Lightning Imaging Sensor (TRMM/LIS) and the future GOES-R Geostationary Lightning Mapper (GLM) are designed to detect total lightning (ground flashes + cloud flashes). However, there is a desire to discriminate ground flashes from cloud flashes from the vantage point of space since this would enhance the overall information content of the satellite lightning data and likely improve its operational and scientific applications (e.g., in severe weather warning, lightning nitrogen oxides studies, and global electric circuit analyses). A Bayesian inversion method was previously introduced for retrieving the fraction of ground flashes in a set of flashes observed from a satellite lightning imager. The method employed a constrained mixed exponential distribution model to describe the lightning optical measurements. To obtain the optimum model parameters (one of which is the ground flash fraction), a scalar function was minimized by a numerical method. In order to improve this optimization, a Grobner basis solution was introduced to obtain analytic representations of the model parameters that serve as a refined initialization scheme to the numerical optimization. In this study, we test the efficacy of the Grobner basis initialization using actual lightning imager measurements and ground flash truth derived from the national lightning network.

  9. Flash/crazing effects on simulator pursuit tracking performance

    NASA Astrophysics Data System (ADS)

    Stamper, D. A.; Lund, D. J.; Levine, R. R.; Molchany, J. W.; Best, P.

    1986-03-01

    Day sights which are purposefully or inadvertently irradiated with laser radiation may become nonfunctional due to cracking or crazing of the optical glass. The degree of performance degradation may be related to the amount of damage to the glass and possible flash blindness from reradiation. Thirty-two male enlisted men and officers tracked a scale model tank through a constant arc at a simulated distance of 1 km, using a laboratory constructed viscous-damped tracking device. There were four crazing groups (4 men/group) under bright and dim ambient light conditions for a total of eight groups. Each man tracked the target during three flash/crazing and three crazing only trials, which were randomly presented during 30 trials. The simulated countermeasure which included the flash and crazing had dramatic effects on tracking performance, even under daylight conditions. Under the most severe degree of crazing, tracking performance was not possible under either ambient light condition. The relatively small amounts of laser radiation used to craze the BK-7 glass used in this study, which lead to significant performance decrements, demonstrates the potential impact of flash/crazing effects on operators of day sights.

  10. NAND FLASH Radiation Tolerant Intelligent Memory Stack (RTIMS FLASH)

    NASA Astrophysics Data System (ADS)

    Sellier, Charles; Wang, Pierre

    2014-08-01

    The NAND Flash Radiation Tolerant and Intelligent Memory Stack (RTIMS FLASH) is a User's Friendly, Plug-and- Play and Radiation Protected high density NAND Flash Memory. It provides a very high density, radiation hardened by design and non-volatile memory module suitable for all space applications such as commercial or scientific geo-stationary missions, earth observation, navigation, manned space vehicles and deep space scientific exploration. The Intelligent Memory Module embeds a very high density of non-volatile NAND Flash memory and one Intelligent Flash Memory Controller (FMC). The FMC provides the module with a full protection against the radiation effects such as SEL, SEFI and SEU. It's also granting the module with bad block immunity as well as high level service functions that will benefit to the user's applications.

  11. Monitoring scaling and dental calculus removal with an optical fluorescence system

    NASA Astrophysics Data System (ADS)

    Sivieri-Araujo, G.; Fontana, C. R.; Costa, M. M.; Rastelli, A. N. S.; Pereira, L. P. C.; Kurachi, C.; Bagnato, V. S.

    2014-08-01

    Fluorescence results from a process that occurs under certain conditions in molecules known as fluorophores, fluorochromes or fluorescent dyes when they absorb light. The molecule is excited to a higher energy state and emits fluorescent light. The emission wavelength is always higher than the excitation wavelength. Optical diagnoses by fluorescence can be used in medicine and dentistry. It does not cause injury to tissues because it is a noninvasive method and can add benefits to clinical treatments. The aim of this case report was to apply an optical fluorescence system for wide-field image viewing and visual monitoring of the management of plaque and dental calculus before and after periodontal scaling to improve the diagnoses and follow-up of patients with periodontal disease. The results suggest that it is possible to observe, with a fluorescence system, residual plaque and calculus that were not easily seen by the naked eye during oral inspection. Thus, the optical technique can potentially improve periodontal screening efforts, especially in patients undergoing periodontal maintenance.

  12. Design of an ultra-thin near-eye display with geometrical waveguide and freeform optics.

    PubMed

    Cheng, Dewen; Wang, Yongtian; Xu, Chen; Song, Weitao; Jin, Guofan

    2014-08-25

    Small thickness and light weight are two important requirements for a see-through near-eye display which are achieved in this paper by using two advanced technologies: geometrical waveguide and freeform optics. A major problem associated with the geometrical waveguide is the stray light which can severely degrade the display quality. The causes and solutions to this problem are thoroughly studied. A mathematical model of the waveguide is established and a non-sequential ray tracing algorithm is developed, which enable us to carefully examine the stray light of the planar waveguide and explore a global searching method to find an optimum design with the least amount of stray light. A projection optics using freeform surfaces on a wedge shaped prism is also designed. The near-eye display integrating the projection optics and the waveguide has a field of view of 28°, an exit pupil diameter of 9.6mm and an exit pupil distance of 20mm. In our final design, the proportion of the stray light energy over the image output energy of the waveguide is reduced to 2%, the modulation transfer function values across the entire field of the eyepiece are above 0.5 at 30 line pairs/mm (lps/mm). A proof-of-concept prototype of the proposed geometrical waveguide near-eye display is developed and demonstrated.

  13. Rotational symmetric HMD with eye-tracking capability

    NASA Astrophysics Data System (ADS)

    Liu, Fangfang; Cheng, Dewen; Wang, Qiwei; Wang, Yongtian

    2016-10-01

    As an important auxiliary function of head-mounted displays (HMDs), eye tracking has an important role in the field of intelligent human-machine interaction. In this paper, an eye-tracking HMD system (ET-HMD) is designed based on the rotational symmetric system. The tracking principle in this paper is based on pupil-corneal reflection. The ET-HMD system comprises three optical paths for virtual display, infrared illumination, and eye tracking. The display optics is shared by three optical paths and consists of four spherical lenses. For the eye-tracking path, an extra imaging lens is added to match the image sensor and achieve eye tracking. The display optics provides users a 40° diagonal FOV with a ״ 0.61 OLED, the 19 mm eye clearance, and 10 mm exit pupil diameter. The eye-tracking path can capture 15 mm × 15 mm of the users' eyes. The average MTF is above 0.1 at 26 lp/mm for the display path, and exceeds 0.2 at 46 lp/mm for the eye-tracking path. Eye illumination is simulated using LightTools with an eye model and an 850 nm near-infrared LED (NIR-LED). The results of the simulation show that the illumination of the NIR-LED can cover the area of the eye model with the display optics that is sufficient for eye tracking. The integrated optical system HMDs with eye-tracking feature can help improve the HMD experience of users.

  14. Time delay and magnification centroid due to gravitational lensing by black holes and naked singularities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Virbhadra, K. S.; Keeton, C. R.; Department of Physics and Astronomy, Rutgers University, 136 Frelinghuysen Road, Piscataway, NJ 08854

    We model the massive dark object at the center of the Galaxy as a Schwarzschild black hole as well as Janis-Newman-Winicour naked singularities, characterized by the mass and scalar charge parameters, and study gravitational lensing (particularly time delay, magnification centroid, and total magnification) by them. We find that the lensing features are qualitatively similar (though quantitatively different) for Schwarzschild black holes, weakly naked, and marginally strongly naked singularities. However, the lensing characteristics of strongly naked singularities are qualitatively very different from those due to Schwarzschild black holes. The images produced by Schwarzschild black hole lenses and weakly naked and marginallymore » strongly naked singularity lenses always have positive time delays. On the other hand, strongly naked singularity lenses can give rise to images with positive, zero, or negative time delays. In particular, for a large angular source position the direct image (the outermost image on the same side as the source) due to strongly naked singularity lensing always has a negative time delay. We also found that the scalar field decreases the time delay and increases the total magnification of images; this result could have important implications for cosmology. As the Janis-Newman-Winicour metric also describes the exterior gravitational field of a scalar star, naked singularities as well as scalar star lenses, if these exist in nature, will serve as more efficient cosmic telescopes than regular gravitational lenses.« less

  15. Glaucoma-induced optic disc morphometric changes and glaucoma diagnostic ability of Heidelberg Retina Tomograph II in highly myopic eyes.

    PubMed

    Mayama, Chihiro; Tsutsumi, Tae; Saito, Hitomi; Asaoka, Ryo; Tomidokoro, Atsuo; Iwase, Aiko; Otani, Shinichiro; Miyata, Kazunori; Araie, Makoto

    2014-01-01

    This study was performed to first investigate the morphological differences in the optic nerve head between highly myopic non-glaucomatous controls and highly myopic glaucomatous eyes in comparison with the differences between emmetropic non-glaucomatous controls and emmetropic glaucomatous eyes using confocal scanning laser ophthalmoscopy. Further, the ability of the apparatus in glaucoma diagnosis in highly myopic eyes was compared with that in emmetropic eyes. Healthy subjects and age-matched patients with early-stage open-angle glaucoma were divided into two groups: emmetropic eyes (-1.0 to +1.0 diopters) and highly myopic eyes (-12.0 to -5.0 diopters).The participants were comprised of 65 emmetropic normal eyes, 59 emmetropic glaucomatous eyes, 62 highly myopic normal eyes, and 68 highly myopic glaucomatous eyes and eyes with pathologic myopia were carefully excluded. Confocal scanning laser tomographic parameters were compared among all subjects after adjustment for age and disc area. The ROC curves and sensitivity and specificity for glaucoma detection using several clinical methods were then compared between the emmetropic and highly myopic eyes. Rim area, cup/disc area ratio, mean cup depth, and cup shape measure of glaucoma eyes are significantly different from those of normal eyes in both highly myopic eyes and emmetropic eyes. Methodological overestimation of retinal nerve fiber layer cross sectional area due to optic disc tilting was suggested in the highly myopic eyes. The diagnostic performance of glaucoma using several discriminant methods significantly deteriorated in the highly myopic eyes. In the highly myopic glaucomatous eyes, confocal scanning laser tomographic parameters were significantly different from that of non-glaucomatous highly myopic eyes but diagnostic performance of glaucoma was deteriorated than that in emmetropic eyes. These findings demonstrate the utility and limitations of the apparatus in diagnosing glaucoma in highly myopic

  16. Lowered threshold energy for femtosecond laser induced optical breakdown in a water based eye model by aberration correction with adaptive optics.

    PubMed

    Hansen, Anja; Géneaux, Romain; Günther, Axel; Krüger, Alexander; Ripken, Tammo

    2013-06-01

    In femtosecond laser ophthalmic surgery tissue dissection is achieved by photodisruption based on laser induced optical breakdown. In order to minimize collateral damage to the eye laser surgery systems should be optimized towards the lowest possible energy threshold for photodisruption. However, optical aberrations of the eye and the laser system distort the irradiance distribution from an ideal profile which causes a rise in breakdown threshold energy even if great care is taken to minimize the aberrations of the system during design and alignment. In this study we used a water chamber with an achromatic focusing lens and a scattering sample as eye model and determined breakdown threshold in single pulse plasma transmission loss measurements. Due to aberrations, the precise lower limit for breakdown threshold irradiance in water is still unknown. Here we show that the threshold energy can be substantially reduced when using adaptive optics to improve the irradiance distribution by spatial beam shaping. We found that for initial aberrations with a root-mean-square wave front error of only one third of the wavelength the threshold energy can still be reduced by a factor of three if the aberrations are corrected to the diffraction limit by adaptive optics. The transmitted pulse energy is reduced by 17% at twice the threshold. Furthermore, the gas bubble motions after breakdown for pulse trains at 5 kilohertz repetition rate show a more transverse direction in the corrected case compared to the more spherical distribution without correction. Our results demonstrate how both applied and transmitted pulse energy could be reduced during ophthalmic surgery when correcting for aberrations. As a consequence, the risk of retinal damage by transmitted energy and the extent of collateral damage to the focal volume could be minimized accordingly when using adaptive optics in fs-laser surgery.

  17. Lowered threshold energy for femtosecond laser induced optical breakdown in a water based eye model by aberration correction with adaptive optics

    PubMed Central

    Hansen, Anja; Géneaux, Romain; Günther, Axel; Krüger, Alexander; Ripken, Tammo

    2013-01-01

    In femtosecond laser ophthalmic surgery tissue dissection is achieved by photodisruption based on laser induced optical breakdown. In order to minimize collateral damage to the eye laser surgery systems should be optimized towards the lowest possible energy threshold for photodisruption. However, optical aberrations of the eye and the laser system distort the irradiance distribution from an ideal profile which causes a rise in breakdown threshold energy even if great care is taken to minimize the aberrations of the system during design and alignment. In this study we used a water chamber with an achromatic focusing lens and a scattering sample as eye model and determined breakdown threshold in single pulse plasma transmission loss measurements. Due to aberrations, the precise lower limit for breakdown threshold irradiance in water is still unknown. Here we show that the threshold energy can be substantially reduced when using adaptive optics to improve the irradiance distribution by spatial beam shaping. We found that for initial aberrations with a root-mean-square wave front error of only one third of the wavelength the threshold energy can still be reduced by a factor of three if the aberrations are corrected to the diffraction limit by adaptive optics. The transmitted pulse energy is reduced by 17% at twice the threshold. Furthermore, the gas bubble motions after breakdown for pulse trains at 5 kilohertz repetition rate show a more transverse direction in the corrected case compared to the more spherical distribution without correction. Our results demonstrate how both applied and transmitted pulse energy could be reduced during ophthalmic surgery when correcting for aberrations. As a consequence, the risk of retinal damage by transmitted energy and the extent of collateral damage to the focal volume could be minimized accordingly when using adaptive optics in fs-laser surgery. PMID:23761849

  18. Study of lobster eye optics with iridium coated x-ray mirrors for a rocket experiment

    NASA Astrophysics Data System (ADS)

    Stehlikova, Veronika; Urban, Martin; Nentvich, Ondrej; Inneman, Adolf; Döhring, Thorsten; Probst, Anne-Catherine

    2017-05-01

    In the field of astronomical X-ray telescopes, different types of optics based on grazing incidence mirrors can be used. This contribution describes the special design of a lobster-eye optics in Schmidt's arrangement, which uses dual reflection to increase the collecting area. The individual mirrors of this wide-field telescope are made of at silicon wafers coated with reflecting iridium layers. This iridium coatings have some advantages compared to more common gold layers as is shown in corresponding simulations. The iridium coating process for the X-ray mirrors was developed within a cooperation of the Aschaffenburg University of Applied Sciences and the Czech Technical University in Prague. Different mirror parameters essential for a proper function of the X-ray optics, like the surface microroughness and the problematic of a good adhesion quality of the coatings were studied. After integration of the individual mirrors into the final lobster-eye optics and the corresponding space qualification testing it is planned to fly the telescope in a recently proposed NASA rocket experiment.

  19. Adaptive optics retinal imaging in the living mouse eye

    PubMed Central

    Geng, Ying; Dubra, Alfredo; Yin, Lu; Merigan, William H.; Sharma, Robin; Libby, Richard T.; Williams, David R.

    2012-01-01

    Correction of the eye’s monochromatic aberrations using adaptive optics (AO) can improve the resolution of in vivo mouse retinal images [Biss et al., Opt. Lett. 32(6), 659 (2007) and Alt et al., Proc. SPIE 7550, 755019 (2010)], but previous attempts have been limited by poor spot quality in the Shack-Hartmann wavefront sensor (SHWS). Recent advances in mouse eye wavefront sensing using an adjustable focus beacon with an annular beam profile have improved the wavefront sensor spot quality [Geng et al., Biomed. Opt. Express 2(4), 717 (2011)], and we have incorporated them into a fluorescence adaptive optics scanning laser ophthalmoscope (AOSLO). The performance of the instrument was tested on the living mouse eye, and images of multiple retinal structures, including the photoreceptor mosaic, nerve fiber bundles, fine capillaries and fluorescently labeled ganglion cells were obtained. The in vivo transverse and axial resolutions of the fluorescence channel of the AOSLO were estimated from the full width half maximum (FWHM) of the line and point spread functions (LSF and PSF), and were found to be better than 0.79 μm ± 0.03 μm (STD)(45% wider than the diffraction limit) and 10.8 μm ± 0.7 μm (STD)(two times the diffraction limit), respectively. The axial positional accuracy was estimated to be 0.36 μm. This resolution and positional accuracy has allowed us to classify many ganglion cell types, such as bistratified ganglion cells, in vivo. PMID:22574260

  20. FLASH Interface; a GUI for managing runtime parameters in FLASH simulations

    NASA Astrophysics Data System (ADS)

    Walker, Christopher; Tzeferacos, Petros; Weide, Klaus; Lamb, Donald; Flocke, Norbert; Feister, Scott

    2017-10-01

    We present FLASH Interface, a novel graphical user interface (GUI) for managing runtime parameters in simulations performed with the FLASH code. FLASH Interface supports full text search of available parameters; provides descriptions of each parameter's role and function; allows for the filtering of parameters based on categories; performs input validation; and maintains all comments and non-parameter information already present in existing parameter files. The GUI can be used to edit existing parameter files or generate new ones. FLASH Interface is open source and was implemented with the Electron framework, making it available on Mac OSX, Windows, and Linux operating systems. The new interface lowers the entry barrier for new FLASH users and provides an easy-to-use tool for experienced FLASH simulators. U.S. Department of Energy (DOE), NNSA ASC/Alliances Center for Astrophysical Thermonuclear Flashes, U.S. DOE NNSA ASC through the Argonne Institute for Computing in Science, U.S. National Science Foundation.

  1. Flash Platform Examination

    DTIC Science & Technology

    2011-03-01

    than would be performed in software”[108]. Uro Tinic, one of the Flash player’s engineers, further clarifies exactly what Flash player 10 hardware...www.adobe.com/products/flashplayer/features/ (Access date: 28 Sep 2009). [109] Uro , T. What Does GPU Acceleration Mean? (online), http...133] Shorten, A. (2009), Design to Development: Flash Catalyst to Flash Builder, In Proceedings of Adobe Max 2009, Los Angeles, CA. 142 DRDC

  2. Beta-zone parapapillary atrophy and multifocal visual evoked potentials in eyes with glaucomatous optic neuropathy

    PubMed Central

    Ketner, Scott; Teng, Christopher C.; Ehrlich, Joshua R.; Raza, Ali S.; Liebmann, Jeffrey M.; Ritch, Robert; Hood, Donald C.

    2015-01-01

    We investigated changes in multifocal visual evoked potential (mfVEP) responses due to beta-zone parapapillary atrophy (βPPA). Patients with glaucomatous optic neuropathy (GON) with or without standard achromatic perimetry (SAP) abnormalities were referred for mfVEP testing during a 2-year period. Eyes with good quality optic disc stereophotographs and reliable SAP results were included. The mfVEP monocular mean latency delays (ms) and amplitudes (SNR) were analyzed. Age, SAP mean deviation (MD), pattern standard deviation (PSD), and spherical equivalent (SE) were analyzed in the multivariate model. Generalized estimated equations were used for comparisons between groups after adjusting for inter-eye associations. Of 394 eyes of 200 patients, 223 (57%) had βPPA. The βPPA eyes were older (59.6 ± 13.7 vs. 56.5 ± 13.7 year, P = 0.02), more myopic (−4.0 ± 3.5 vs. −1.3 ± 3.5 D, P < 0.01), and had poorer SAP scores (MD: −4.9 ± 5.2 vs. −2.6 ± 5.2 dB, P < 0.01; PSD: 4.3 ± 2.9 vs. 2.5 ± 3.0 dB, P < 0.01). By univariate analysis, mean latencies were longer in βPPA eyes (6.1 ± 5.3 vs. 4.0 ± 5.5 ms, P < 0.01). After adjusting for differences in SE, age, and SAP MD, there was no significant difference between the two groups (P = 0.09). βPPA eyes had lower amplitude log SNR (0.49 ± 0.16 vs. 0.56 ± 0.15, P < 0.01), which lost significance (P = 0.51) after adjusting for MD and PSD. Although eyes with βPPA had significantly lower amplitudes and prolonged latencies than eyes without βPPA, these differences were attributable to differences in SAP severity, age, and refractive error. Thus, βPPA does not appear to be an independent factor affecting mfVEP responses in eyes with GON. PMID:21735265

  3. Nonarteritic ischemic optic neuropathy secondary to severe ocular hypertension masked by interface fluid in a post-LASIK eye.

    PubMed

    Pham, Mai T; Peck, Rachel E; Dobbins, Kendall R B

    2013-06-01

    We report a case of ischemic optic neuropathy arising from elevated intraocular pressure (IOP) masked by interface fluid in a post-laser in situ keratomileusis (LASIK) eye. A 51-year-old man, who had had LASIK 6 years prior to presentation, sustained blunt trauma to the left eye that resulted in a hyphema and ocular hypertension. Elevated IOP resulted in accumulation of fluid in the stromal bed-LASIK flap interface, leading to underestimation of IOP when measured centrally over the flap. After days of unrecognized ocular hypertension, ischemic optic neuropathy developed. To our knowledge, this is the first reported case of ischemic optic neuropathy resulting from underestimated IOP measurements in a post-LASIK patient. It highlights the inaccuracy of IOP measurements in post-LASIK eyes and a vision-threatening potential complication. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. A new experimental device to evaluate eye ulcers using a multispectral electrical impedance technique

    NASA Astrophysics Data System (ADS)

    Bellotti, Mariela I.; Bast, Walter; Berra, Alejandro; Bonetto, Fabián J.

    2011-07-01

    We present a novel experimental technique to determine eye ulcers in animals using a spectral electrical impedance technique. We expect that this technique will be useful in dry eye syndrome. We used a sensor that is basically a platinum (Pt) microelectrode electrically insulated by glass from a cylindrical stainless steel counter-electrode. This sensor was applied to the naked eye of New Zealand rabbits (2.0-3.5 kg in weight). Whereas half of the eyes were normal (control), we applied to the remainder a few drops of 20% (v/v) alcohol to produce an ulcer in the eye. Using a multispectral electrical impedance system we measured ulcerated and control eyes and observed significant difference between normal and pathological samples. We also investigated the effects of different applied pressures and natural degradation of initially normal eyes as a function of time. We believe that this technique could be sufficiently sensitive and repetitive to help diagnose ocular surface diseases such as dry eye syndrome.

  5. A new experimental device to evaluate eye ulcers using a multispectral electrical impedance technique.

    PubMed

    Bellotti, Mariela I; Bast, Walter; Berra, Alejandro; Bonetto, Fabián J

    2011-07-01

    We present a novel experimental technique to determine eye ulcers in animals using a spectral electrical impedance technique. We expect that this technique will be useful in dry eye syndrome. We used a sensor that is basically a platinum (Pt) microelectrode electrically insulated by glass from a cylindrical stainless steel counter-electrode. This sensor was applied to the naked eye of New Zealand rabbits (2.0-3.5 kg in weight). Whereas half of the eyes were normal (control), we applied to the remainder a few drops of 20% (v/v) alcohol to produce an ulcer in the eye. Using a multispectral electrical impedance system we measured ulcerated and control eyes and observed significant difference between normal and pathological samples. We also investigated the effects of different applied pressures and natural degradation of initially normal eyes as a function of time. We believe that this technique could be sufficiently sensitive and repetitive to help diagnose ocular surface diseases such as dry eye syndrome.

  6. Combined application of BDNF to the eye and brain enhances ganglion cell survival and function in the cat after optic nerve injury.

    PubMed

    Weber, Arthur J; Viswanáthan, Suresh; Ramanathan, Chidambaram; Harman, Christine D

    2010-01-01

    To determine whether application of BDNF to the eye and brain provides a greater level of neuroprotection after optic nerve injury than treatment of the eye alone. Retinal ganglion cell survival and pattern electroretinographic responses were compared in normal cat eyes and in eyes that received (1) a mild nerve crush and no treatment, (2) a single intravitreal injection of BDNF at the time of the nerve injury, or (3) intravitreal treatment combined with 1 to 2 weeks of continuous delivery of BDNF to the visual cortex, bilaterally. Relative to no treatment, administration of BDNF to the eye alone resulted in a significant increase in ganglion cell survival at both 1 and 2 weeks after nerve crush (1 week, 79% vs. 55%; 2 weeks, 60% vs. 31%). Combined treatment of the eye and visual cortex resulted in a modest additional increase (17%) in ganglion cell survival in the 1-week eyes, a further significant increase (55%) in the 2-week eyes, and ganglion cell survival levels for both that were comparable to normal (92%-93% survival). Pattern ERG responses for all the treated eyes were comparable to normal at 1 week after injury; however, at 2 weeks, only the responses of eyes receiving the combined BDNF treatment remained so. Although treatment of the eye alone with BDNF has a significant impact on ganglion cell survival after optic nerve injury, combined treatment of the eye and brain may represent an even more effective approach and should be considered in the development of future optic neuropathy-related neuroprotection strategies.

  7. Effective algorithm for ray-tracing simulations of lobster eye and similar reflective optical systems

    NASA Astrophysics Data System (ADS)

    Tichý, Vladimír; Hudec, René; Němcová, Šárka

    2016-06-01

    The algorithm presented is intended mainly for lobster eye optics. This type of optics (and some similar types) allows for a simplification of the classical ray-tracing procedure that requires great many rays to simulate. The method presented performs the simulation of a only few rays; therefore it is extremely effective. Moreover, to simplify the equations, a specific mathematical formalism is used. Only a few simple equations are used, therefore the program code can be simple as well. The paper also outlines how to apply the method to some other reflective optical systems.

  8. Influence of the corneal optical zone on the point-spread function of the human eye

    NASA Astrophysics Data System (ADS)

    Rol, Pascal O.; Parel, Jean-Marie A.

    1992-08-01

    In refractive surgery, a number of surgical techniques have been developed to correct ametropia (refractive defaults) of the eye by changing the exterior shape of the cornea. Because the air-cornea interface makes up for about two thirds of the refractive power of the eye, a refractive correction can be obtained by a suitable reshaping of the cornea. Postoperatively, it is usually observed that the corneal region consists of two or more zones which are characterized by different optical parameters exhibiting in particular different focal distances. Under normal circumstances, only the central area of the cornea is involved in the formation of the retinal image. However, if part of the light entering the eye through peripheral portions of the cornea with refractive properties different from the central area can pass the pupil, an out-of-focus `ghost' image may be overlaid on the retina causing a blur. In such a case the resolution, and the contrast performance of the eye which is expected from a successful operation, may be reduced. This study is an attempt to quantify the vision blur as a function of the diameter of the central zone, i.e., the optical zone which is of importance for vision.

  9. Christoph Scheiner and the optics of the eye. (German Title: Christoph Scheiner und die Optik des Auges)

    NASA Astrophysics Data System (ADS)

    Daxecker, Franz

    Some of Scheiner's discoveries and experiments are taken from the books «Oculus», (Innsbruck 1619) and «Rosa Ursina sive Sol» (Rome 1626-1630): determination of the radius of curvature of the cornea, discovery of the nasal exit of the visual nerve, increase in the curvature of the lens in case of accommodation, anatomy of the eye, light reaction of the pupil, contraction of the pupil during accommodation, Scheiner's test (double images caused by ametropia), stenopeic effect, crossing rays in the eye, aperture, description of the cataract treatment, refractive indices of various parts of the eye, eye model, visual pivot angle of the eye, proof of crossing rays on the retina, comparison of the camera obscura and the optics of the eye.

  10. Retinal Capillary Network and Foveal Avascular Zone in Eyes with Vein Occlusion and Fellow Eyes Analyzed With Optical Coherence Tomography Angiography.

    PubMed

    Adhi, Mehreen; Filho, Marco A Bonini; Louzada, Ricardo N; Kuehlewein, Laura; de Carlo, Talisa E; Baumal, Caroline R; Witkin, Andre J; Sadda, Srinivas R; Sarraf, David; Reichel, Elias; Duker, Jay S; Waheed, Nadia K

    2016-07-01

    To evaluate the perifoveolar retinal capillary network at different depths and to quantify the foveal avascular zone (FAZ) in eyes with retinal vein occlusion (RVO) compared with their fellow eyes and healthy controls using spectral-domain optical coherence tomography angiography (SD-OCTA). We prospectively recruited 23 patients with RVO including 15 eyes with central RVO (CRVO) and 8 eyes with branch RVO (BRVO), their fellow eyes, and 8 age-matched healthy controls (8 eyes) for imaging on prototype OCTA software within RTVue-XR Avanti. The 3 × 3 mm and 6 × 6 mm en face angiograms of superficial and deep retinal capillary plexuses were segmented. Perifoveolar retinal capillary network was analyzed and FAZ was quantified. Decrease in vascular perfusion at the deep plexus was observed in all eyes with CRVO (8/8, 100%) and BRVO (6/6, 100%) without cystoid macular edema, and in 8 of 15 (53%) and 2 of 8 (25%) of the fellow eyes, respectively. Vascular tortuosity was observed in 13 of 15 (87%) CRVO and 5 of 8 (63%) BRVO eyes. Collaterals were seen in 10 of 15 (67%) CRVO and 5 of 8 (63%) BRVO eyes. Mean FAZ area was larger in eyes with RVO than their fellow eyes (1.13 ± 0.25 mm2 versus 0.58 ± 0.28 mm2; P = 0.007) and controls (1.13 ± 0.25 mm2 versus 0.30 ± 0.09 mm2; P < 0.0001), and in fellow eyes of RVO patients when compared to controls (0.58 ± 0.28 mm2 versus 0.30 ± 0.09 mm2; P = 0.01). Spectral-domain OCTA reveals abnormalities at different levels of perifoveolar retinal capillary network and is able to quantify the FAZ in RVO. Longitudinal studies may be considered to evaluate the clinical utility of OCTA in RVO and other retinal vascular diseases.

  11. Virtually Naked: Virtual Environment Reveals Sex-Dependent Nature of Skin Disclosure

    PubMed Central

    Lomanowska, Anna M.; Guitton, Matthieu J.

    2012-01-01

    The human tendency to reveal or cover naked skin reflects a competition between the individual propensity for social interactions related to sexual appeal and interpersonal touch versus climatic, environmental, physical, and cultural constraints. However, due to the ubiquitous nature of these constraints, isolating on a large scale the spontaneous human tendency to reveal naked skin has remained impossible. Using the online 3-dimensional virtual world of Second Life, we examined spontaneous human skin-covering behavior unhindered by real-world climatic, environmental, and physical variables. Analysis of hundreds of avatars revealed that virtual females disclose substantially more naked skin than virtual males. This phenomenon was not related to avatar hypersexualization as evaluated by measurement of sexually dimorphic body proportions. Furthermore, analysis of skin-covering behavior of a population of culturally homogeneous avatars indicated that the propensity of female avatars to reveal naked skin persisted despite explicit cultural norms promoting less revealing attire. These findings have implications for further understanding how sex-specific aspects of skin disclosure influence human social interactions in both virtual and real settings. PMID:23300580

  12. Virtually naked: virtual environment reveals sex-dependent nature of skin disclosure.

    PubMed

    Lomanowska, Anna M; Guitton, Matthieu J

    2012-01-01

    The human tendency to reveal or cover naked skin reflects a competition between the individual propensity for social interactions related to sexual appeal and interpersonal touch versus climatic, environmental, physical, and cultural constraints. However, due to the ubiquitous nature of these constraints, isolating on a large scale the spontaneous human tendency to reveal naked skin has remained impossible. Using the online 3-dimensional virtual world of Second Life, we examined spontaneous human skin-covering behavior unhindered by real-world climatic, environmental, and physical variables. Analysis of hundreds of avatars revealed that virtual females disclose substantially more naked skin than virtual males. This phenomenon was not related to avatar hypersexualization as evaluated by measurement of sexually dimorphic body proportions. Furthermore, analysis of skin-covering behavior of a population of culturally homogeneous avatars indicated that the propensity of female avatars to reveal naked skin persisted despite explicit cultural norms promoting less revealing attire. These findings have implications for further understanding how sex-specific aspects of skin disclosure influence human social interactions in both virtual and real settings.

  13. Capture of visual direction in dynamic vergence is reduced with flashed monocular lines.

    PubMed

    Jaschinski, Wolfgang; Jainta, Stephanie; Schürer, Michael

    2006-08-01

    The visual direction of a continuously presented monocular object is captured by the visual direction of a closely adjacent binocular object, which questions the reliability of nonius lines for measuring vergence. This was shown by Erkelens, C. J., and van Ee, R. (1997a,b) [Capture of the visual direction: An unexpected phenomenon in binocular vision. Vision Research, 37, 1193-1196; Capture of the visual direction of monocular objects by adjacent binocular objects. Vision Research, 37, 1735-1745] stimulating dynamic vergence by a counter phase oscillation of two square random-dot patterns (one to each eye) that contained a smaller central dot-free gap (of variable width) with a vertical monocular line oscillating in phase with the random-dot pattern of the respective eye; subjects adjusted the motion-amplitude of the line until it was perceived as (nearly) stationary. With a continuously presented monocular line, we replicated capture of visual direction provided the dot-free gap was narrow: the adjusted motion-amplitude of the line was similar as the motion-amplitude of the random-dot pattern, although large vergence errors occurred. However, when we flashed the line for 67 ms at the moments of maximal and minimal disparity of the vergence stimulus, we found that the adjusted motion-amplitude of the line was smaller; thus, the capture effect appeared to be reduced with flashed nonius lines. Accordingly, we found that the objectively measured vergence gain was significantly correlated (r=0.8) with the motion-amplitude of the flashed monocular line when the separation between the line and the fusion contour was at least 32 min arc. In conclusion, if one wishes to estimate the dynamic vergence response with psychophysical methods, effects of capture of visual direction can be reduced by using flashed nonius lines.

  14. Q2122-444: A NAKED ACTIVE GALACTIC NUCLEUS FULLY DRESSED

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gliozzi, M.; Satyapal, S.; Panessa, F.

    Based on previous spectral and temporal optical studies, Q2122-444 has been classified as a naked active galactic nucleus (AGN) or true type 2 AGN, that is, an AGN that genuinely lacks a broad-line region (BLR). Its optical spectrum seemed to possess only narrow forbidden emission lines that are typical of type 2 (obscured) AGNs, but the long-term optical light curve, obtained from a monitoring campaign over more than two decades, showed strong variability, apparently ruling out the presence of heavy obscuration. Here we present the results from a {approx}40 ks XMM-Newton observation of Q2122-444 carried out to shed light onmore » the energetics of this enigmatic AGN. The X-ray analysis was complemented with Australia Telescope Compact Array radio data to assess the possible presence of a jet, and with new NTT/EFOSC2 optical spectroscopic data to verify the actual absence of a BLR. The higher-quality optical data revealed the presence of strong and broad Balmer lines that are at odds with the previous spectral classification of this AGN. The lack of detection of radio emission rules out the presence of a jet. The X-ray data combined with simultaneous UV observations carried out by the Optical Monitor (OM) aboard XMM-Newton confirm that Q2122-444 is a typical type 1 AGN without any significant intrinsic absorption. New estimates of the black hole mass independently obtained from the broad Balmer lines and from a new scaling technique based on X-ray spectral data suggest that Q2122-444 is accreting at a relatively high rate in Eddington units.« less

  15. Orbital Radiotherapy Combined With Corticosteroid Treatment for Thyroid Eye Disease-Compressive Optic Neuropathy.

    PubMed

    Gold, Katherine G; Scofield, Stacy; Isaacson, Steven R; Stewart, Michael W; Kazim, Michael

    To evaluate the effectiveness of orbital radiotherapy (ORT) in the treatment of thyroid eye disease (TED)-compressive optic neuropathy. A retrospective review of patients with corticosteroid-responsive compressive optic neuropathy due to TED treated with ORT. Study was conducted in compliance with Health Insurance Portability and Accountability Act. One hundred four patients (163 orbits) with a mean age of 61.7 years met inclusion criteria. Seventy-four percent (77/104) were female, and 32.7% (34/104) were current or previous smokers. A total absorbed dose of 2000 cGy fractionated in 10 treatment doses over the course of 2 weeks was administered to the retroocular tissues according to a standard protocol. The primary end point was failure of ORT, defined as persistent optic neuropathy following completion of radiotherapy that mandated urgent orbital decompression surgery. Ninety-eight of 104 (94%) patients or 152 of 163 (93.3%) orbits did not require orbital decompression surgery during the acute phase. Patients who responded successfully to ORT had similar improvements in visual acuity, color vision, Humphrey threshold visual field testing, and afferent pupillary defects compared with patients who failed ORT and underwent urgent decompression surgery. Only 36.7% of successfully treated patients ultimately underwent elective surgery, including orbital decompression, strabismus, or eyelid surgery, during the inactive phase of TED. The data from this study, the largest retrospective review reported to date, supports the use of ORT in eyes with corticosteroid-responsive TED-compressive optic neuropathy. ORT may favorably alter the natural history of active-phase TED by preventing recurrent compressive optic neuropathy after withdrawal of corticosteroids.

  16. Optical interferometer testbed

    NASA Technical Reports Server (NTRS)

    Blackwood, Gary H.

    1991-01-01

    Viewgraphs on optical interferometer testbed presented at the MIT Space Research Engineering Center 3rd Annual Symposium are included. Topics covered include: space-based optical interferometer; optical metrology; sensors and actuators; real time control hardware; controlled structures technology (CST) design methodology; identification for MIMO control; FEM/ID correlation for the naked truss; disturbance modeling; disturbance source implementation; structure design: passive damping; low authority control; active isolation of lightweight mirrors on flexible structures; open loop transfer function of mirror; and global/high authority control.

  17. All-digital full waveform recording photon counting flash lidar

    NASA Astrophysics Data System (ADS)

    Grund, Christian J.; Harwit, Alex

    2010-08-01

    Current generation analog and photon counting flash lidar approaches suffer from limitation in waveform depth, dynamic range, sensitivity, false alarm rates, optical acceptance angle (f/#), optical and electronic cross talk, and pixel density. To address these issues Ball Aerospace is developing a new approach to flash lidar that employs direct coupling of a photocathode and microchannel plate front end to a high-speed, pipelined, all-digital Read Out Integrated Circuit (ROIC) to achieve photon-counting temporal waveform capture in each pixel on each laser return pulse. A unique characteristic is the absence of performance-limiting analog or mixed signal components. When implemented in 65nm CMOS technology, the Ball Intensified Imaging Photon Counting (I2PC) flash lidar FPA technology can record up to 300 photon arrivals in each pixel with 100 ps resolution on each photon return, with up to 6000 range bins in each pixel. The architecture supports near 100% fill factor and fast optical system designs (f/#<1), and array sizes to 3000×3000 pixels. Compared to existing technologies, >60 dB ultimate dynamic range improvement, and >104 reductions in false alarm rates are anticipated, while achieving single photon range precision better than 1cm. I2PC significantly extends long-range and low-power hard target imaging capabilities useful for autonomous hazard avoidance (ALHAT), navigation, imaging vibrometry, and inspection applications, and enables scannerless 3D imaging for distributed target applications such as range-resolved atmospheric remote sensing, vegetation canopies, and camouflage penetration from terrestrial, airborne, GEO, and LEO platforms. We discuss the I2PC architecture, development status, anticipated performance advantages, and limitations.

  18. Spin precession in a black hole and naked singularity spacetimes

    NASA Astrophysics Data System (ADS)

    Chakraborty, Chandrachur; Kocherlakota, Prashant; Joshi, Pankaj S.

    2017-02-01

    We propose here a specific criterion to address the existence or otherwise of Kerr naked singularities, in terms of the precession of the spin of a test gyroscope due to the frame dragging by the central spinning body. We show that there is indeed an important characteristic difference in the behavior of gyro spin precession frequency in the limit of approach to these compact objects, and this can be used, in principle, to differentiate the naked singularity from a black hole. Specifically, if gyroscopes are fixed all along the polar axis up to the horizon of a Kerr black hole, the precession frequency becomes arbitrarily high, blowing up as the event horizon is approached. On the other hand, in the case of naked singularity, this frequency remains always finite and well behaved. Interestingly, this behavior is intimately related to and is governed by the geometry of the ergoregion in each of these cases, which we analyze here. One intriguing behavior that emerges is, in the Kerr naked singularity case, the Lense-Thirring precession frequency (ΩLT ) of the gyroscope due to frame-dragging effect decreases as (ΩLT∝r ) after reaching a maximum, in the limit of r =0 , as opposed to r-3 dependence in all other known astrophysical cases.

  19. Do you see what I see? Optical morphology and visual capability of ‘disco’ clams (Ctenoides ales)

    PubMed Central

    Dubielzig, Richard R.; Schobert, Charles S.; Teixeira, Leandro B.; Li, Jingchun

    2017-01-01

    ABSTRACT The ‘disco’ clam Ctenoides ales (Finlay, 1927) is a marine bivalve that has a unique, vivid flashing display that is a result of light scattering by silica nanospheres and rapid mantle movement. The eyes of C. ales were examined to determine their visual capabilities and whether the clams can see the flashing of conspecifics. Similar to the congener C. scaber, C. ales exhibits an off-response (shadow reflex) and an on-response (light reflex). In field observations, a shadow caused a significant increase in flash rate from a mean of 3.9 Hz to 4.7 Hz (P=0.0016). In laboratory trials, a looming stimulus, which increased light intensity, caused a significant increase in flash rate from a median of 1.8 Hz to 2.2 Hz (P=0.0001). Morphological analysis of the eyes of C. ales revealed coarsely-packed photoreceptors lacking sophisticated structure, resulting in visual resolution that is likely too low to detect the flashing of conspecifics. As the eyes of C. ales are incapable of perceiving conspecific flashing, it is likely that their vision is instead used to detect predators. PMID:28396488

  20. Enhanced optical discrimination system based on switchable retroreflective films

    NASA Astrophysics Data System (ADS)

    Schultz, Phillip; Heikenfeld, Jason

    2016-04-01

    Reported herein is the design, characterization, and demonstration of a laser interrogation and response optical discrimination system based on large-area corner-cube retroreflective films. The switchable retroreflective films use light-scattering liquid crystal to modulate retroreflected intensity. The system can operate with multiple wavelengths (visible to infrared) and includes variable divergence optics for irradiance adjustments and ease of system alignment. The electronic receiver and switchable retroreflector offer low-power operation (<4 mW standby) on coin cell batteries with rapid interrogation to retroreflected signal reception response times (<15 ms). The entire switchable retroreflector film is <1 mm thick and is flexible for optimal placement and increased angular response. The system was demonstrated in high ambient lighting conditions (daylight, 18k lux) with a visible 10-mW output 635-nm source out to a distance of 400 m (naked eye detection). Nighttime demonstrations were performed using a 1.5-mW, 850-nm infrared laser diode out to a distance of 400 m using a night vision camera. This system could have tagging and conspicuity applications in commercial or military settings.

  1. Lunar Impact Flash Locations

    NASA Technical Reports Server (NTRS)

    Moser, D. E.; Suggs, R. M.; Kupferschmidt, L.; Feldman, J.

    2015-01-01

    A bright impact flash detected by the NASA Lunar Impact Monitoring Program in March 2013 brought into focus the importance of determining the impact flash location. A process for locating the impact flash, and presumably its associated crater, was developed using commercially available software tools. The process was successfully applied to the March 2013 impact flash and put into production on an additional 300 impact flashes. The goal today: provide a description of the geolocation technique developed.

  2. Laser flash photolysis studies of atmospheric free radical chemistry using optical diagnostic techniques

    NASA Technical Reports Server (NTRS)

    Wine, Paul H.; Nicovich, J. M.; Hynes, Anthony J.; Stickel, Robert E.; Thorn, R. P.; Chin, Mian; Cronkhite, Jeffrey A.; Shackelford, Christie J.; Zhao, Zhizhong; Daykin, Edward P.

    1993-01-01

    Some recent studies carried out in our laboratory are described where laser flash photolytic production of reactant free radicals has been combined with reactant and/or product detection using time-resolved optical techniques to investigate the kinetics and mechanisms of important atmospheric chemical reactions. Discussed are (1) a study of the radical-radical reaction O + BrO yields Br + O2 where two photolysis lasers are employed to prepare the reaction mixture and where the reactants O and BrO are monitored simultaneously using atomic resonance fluorescence to detect O and multipass UV absorption to detect BrO; (2) a study of the reaction of atomic chlorine with dimethylsulfide (CH3SCH3) where atomic resonance fluorescence detection of Cl is employed to elucidate the kinetics and tunable diode laser absorption spectroscopy is employed to investigate the HCl product yield; and (3) a study of the aqueous phase chemistry of Cl2(-) radicals where longpath UV absorption spectroscopy is employed to investigate the kinetics of the Cl2(-) + H2O reaction.

  3. Optical Coherence Tomography Angiography in Optic Disc Swelling.

    PubMed

    Fard, Masoud Aghsaei; Jalili, Jalil; Sahraiyan, Alireza; Khojasteh, Hassan; Hejazi, Marjane; Ritch, Robert; Subramanian, Prem S

    2018-05-04

    To compare optical coherence tomography angiography (OCT-A) of peripapillary total vasculature and capillaries in patients with optic disc swelling. Cross-sectional study. Twenty nine eyes with acute nonarteritic anterior ischemic optic neuropathy (NAION), 44 eyes with papilledema, 8 eyes with acute optic neuritis, and 48 eyes of normal subjects were imaged using OCT-A. Peripapillary total vasculature information was recorded using a commercial vessel density map. Customized image analysis with major vessel removal was also used to measure whole-image capillary density and peripapillary capillary density (PCD). Mixed models showed that the peripapillary total vasculature density values were significantly lower in NAION eyes, followed by papilledema eyes and control eyes, using commercial software (P < .0001 for all comparisons). The customized software also showed significantly lower PCD of NAION eyes compared with papilledema eyes (all P < .001), but did not show significant differences between papilledema and control subjects. Our software showed significantly lower whole image and PCD in eyes with optic neuritis than papilledema. There was no significant difference between NAION and optic neuritis using our software. The area under the receiver operating curves for discriminating NAION from papilledema eyes and optic neuritis from papilledema eyes was highest for whole-image capillary density (0.94 and 0.80, respectively) with our software, followed by peripapillary total vasculature (0.9 and 0.74, respectively ) with commercial software. OCT-A is helpful to distinguish NAION and papillitis from papilledema. Whole-image capillary density had the greatest diagnostic accuracy for differentiating disc swelling. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. The Evaluation of Anatomic and Functional Changes in Unilateral Moderate Amblyopic Eyes Using Optical Coherence Tomography and Pupil Cycle Time.

    PubMed

    Kusbeci, Tuncay; Karti, Omer; Karahan, Eyyup; Oguztoreli, Mustafa

    2017-12-01

    To investigate whether macular anatomic structure and afferent visual system function differ among amblyopic eyes, non-amblyopic fellow eyes, and controls, using spectral-domain optical coherence tomography (SD-OCT), and pupil cycle time (PCT). This observational, cross-sectional study included 30 patients with unilateral amblyopia and 30 healthy subjects. Optical coherence tomography (OCT) and pupil cycle time (PCT) were used to evaluate patients with unilateral amblyopia and were compared with their non-amblyopic fellow eyes and age- and gender-matched healthy eyes (30 participants). The amblyopic eyes were separated into two groups: anisometropic amblyopia (n = 16) and strabismic amblyopia (n = 14). OCT maps were used to calculate central macular thickness (CMT), retinal nerve fiber layer thickness (RNFLT), and ganglion cell-inner plexiform layer (GC-IPL) thickness. The average RNFLT, GC-IPL thickness, and CMT did not show any significant differences among the amblyopic eyes, non-amblyopic fellow eyes and controls (p > 0.05, Kruskal-Wallis test). Mean PCT was 773.57 ± 64 msn in strabismic eyes, 771.25 ± 58 msn in anisometropic eyes, 778.00 ± 72 msn in non-amblyopic fellow eyes, and 774.75 ± 69 msn in control eyes. The differences among the amblyopic eyes, its fellow and control eyes were not statistically significant (p > 0.05, Kruskal-Wallis test). In this study, we investigated morphological and functional differences among amblyopic eyes, non-amblyopic fellow eyes and controls by using SD-OCT and PCT. We did not find anatomical or functional changes in amblyopic eyes.

  5. Hartmann wavefront sensors and their application at FLASH.

    PubMed

    Keitel, Barbara; Plönjes, Elke; Kreis, Svea; Kuhlmann, Marion; Tiedtke, Kai; Mey, Tobias; Schäfer, Bernd; Mann, Klaus

    2016-01-01

    Different types of Hartmann wavefront sensors are presented which are usable for a variety of applications in the soft X-ray spectral region at FLASH, the free-electron laser (FEL) in Hamburg. As a typical application, online measurements of photon beam parameters during mirror alignment are reported on. A compact Hartmann sensor, operating in the wavelength range from 4 to 38 nm, was used to determine the wavefront quality as well as aberrations of individual FEL pulses during the alignment procedure. Beam characterization and alignment of the focusing optics of the FLASH beamline BL3 were performed with λ(13.5 nm)/116 accuracy for wavefront r.m.s. (w(rms)) repeatability, resulting in a reduction of w(rms) by 33% during alignment.

  6. Energy and Emission Characteristics of a Short-Arc Xenon Flash Lamp Under "Saturated" Optical Brightness Conditions

    NASA Astrophysics Data System (ADS)

    Kamrukov, A. S.; Kireev, S. G.; Kozlov, N. P.; Shashkovskii, S. G.

    2017-09-01

    We present the results of a study of the electrical, energy, and spectral brightness characteristics of an experimental three-electrode high-pressure xenon flash lamp under conditions ensuring close to maximum possible spectral brightness for the xenon emission. We show that under saturated optical brightness conditions (brightness temperature in the visible region of the spectrum 30,000 K), emission of a pulsed discharge in xenon is quite different from the emission from an ideal blackbody: the maximum brightness temperatures are 24,000 K in the short-wavelength UV region and 19,000 K in the near IR range. The relative fraction of UV radiation in the emission spectrum of the lamp is >50%, which lets us consider such lamps as promising broadband sources of radiation with high spectral brightness for many important practical applications.

  7. A light writable microfluidic "flash memory": optically addressed actuator array with latched operation for microfluidic applications.

    PubMed

    Hua, Zhishan; Pal, Rohit; Srivannavit, Onnop; Burns, Mark A; Gulari, Erdogan

    2008-03-01

    This paper presents a novel optically addressed microactuator array (microfluidic "flash memory") with latched operation. Analogous to the address-data bus mediated memory address protocol in electronics, the microactuator array consists of individual phase-change based actuators addressed by localized heating through focused light patterns (address bus), which can be provided by a modified projector or high power laser pointer. A common pressure manifold (data bus) for the entire array is used to generate large deflections of the phase change actuators in the molten phase. The use of phase change material as the working media enables latched operation of the actuator array. After the initial light "writing" during which the phase is temporarily changed to molten, the actuated status is self-maintained by the solid phase of the actuator without power and pressure inputs. The microfluidic flash memory can be re-configured by a new light illumination pattern and common pressure signal. The proposed approach can achieve actuation of arbitrary units in a large-scale array without the need for complex external equipment such as solenoid valves and electrical modules, which leads to significantly simplified system implementation and compact system size. The proposed work therefore provides a flexible, energy-efficient, and low cost multiplexing solution for microfluidic applications based on physical displacements. As an example, the use of the latched microactuator array as "normally closed" or "normally open" microvalves is demonstrated. The phase-change wax is fully encapsulated and thus immune from contamination issues in fluidic environments.

  8. A psychological perspective of eye floaters.

    PubMed

    Cipolletta, Sabrina; Beccarello, Alessandra; Galan, Alessandro

    2012-11-01

    Patients experiencing flashes and spots in their perceptive fields often resort to consulting an ophthalmologist without finding an answer, mainly because these symptoms are not necessarily associated with pathology of the eye. The purpose of our research study was to understand the experience of these patients, differentiate among them, and propose different ways of treating them. We carried out an eye examination and echography, individual semistructured interviews, and dependency grids with 11 patients at the ophthalmology department of a public hospital in northern Italy. We found that individuals' ways of experiencing and reacting to eye floaters might be different and might depend on the perception of the disease, the personal explanation, the solutions tried, the trust placed in medicine, self-construction, and the dispersion of dependency. Understanding the experiences of patients suffering from eye floaters might help health care professionals to personalize their approaches to these patients.

  9. The Naked Mole-Rat Response to Oxidative Stress: Just Deal with It

    PubMed Central

    Lewis, Kaitlyn N.; Andziak, Blazej; Yang, Ting

    2013-01-01

    Abstract Significance: The oxidative stress theory of aging has been the most widely accepted theory of aging providing insights into why we age and die for over 50 years, despite mounting evidence from a multitude of species indicating that there is no direct relationship between reactive oxygen species (ROS) and longevity. Here we explore how different species, including the longest lived rodent, the naked mole-rat, have defied the most predominant aging theory. Recent Advances: In the case of extremely long-lived naked mole-rat, levels of ROS production are found to be similar to mice, antioxidant defenses unexceptional, and even under constitutive conditions, naked mole-rats combine a pro-oxidant intracellular milieu with high, steady state levels of oxidative damage. Clearly, naked mole-rats can tolerate this level of oxidative stress and must have mechanisms in place to prevent its translation into potentially lethal diseases. Critical Issues: In addition to the naked mole-rat, other species from across the phylogenetic spectrum and even certain mouse strains do not support this theory. Moreover, overexpressing or knocking down antioxidant levels alters levels of oxidative damage and even cancer incidence, but does not modulate lifespan. Future Directions: Perhaps, it is not oxidative stress that modulates healthspan and longevity, but other cytoprotective mechanisms that allow animals to deal with high levels of oxidative damage and stress, and nevertheless live long, relatively healthy lifespans. Studying these mechanisms in uniquely long-lived species, like the naked mole-rat, may help us tease out the key contributors to aging and longevity. Antioxid. Redox Signal. 19, 1388–1399. PMID:23025341

  10. Beta-zone parapapillary atrophy and multifocal visual evoked potentials in eyes with glaucomatous optic neuropathy.

    PubMed

    De Moraes, Carlos Gustavo; Ketner, Scott; Teng, Christopher C; Ehrlich, Joshua R; Raza, Ali S; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C

    2011-08-01

    We investigated changes in multifocal visual evoked potential (mfVEP) responses due to beta-zone parapapillary atrophy (ßPPA). Patients with glaucomatous optic neuropathy (GON) with or without standard achromatic perimetry (SAP) abnormalities were referred for mfVEP testing during a 2-year period. Eyes with good quality optic disc stereophotographs and reliable SAP results were included. The mfVEP monocular mean latency delays (ms) and amplitudes (SNR) were analyzed. Age, SAP mean deviation (MD), pattern standard deviation (PSD), and spherical equivalent (SE) were analyzed in the multivariate model. Generalized estimated equations were used for comparisons between groups after adjusting for inter-eye associations. Of 394 eyes of 200 patients, 223 (57%) had ßPPA. The ßPPA eyes were older (59.6 ± 13.7 vs. 56.5 ± 13.7 year, P = 0.02), more myopic (-4.0 ± 3.5 vs. -1.3 ± 3.5 D, P < 0.01), and had poorer SAP scores (MD: -4.9 ± 5.2 vs. -2.6 ± 5.2 dB, P < 0.01; PSD: 4.3 ± 2.9 vs. 2.5 ± 3.0 dB, P < 0.01). By univariate analysis, mean latencies were longer in ßPPA eyes (6.1 ± 5.3 vs. 4.0 ± 5.5 ms, P < 0.01). After adjusting for differences in SE, age, and SAP MD, there was no significant difference between the two groups (P = 0.09). ßPPA eyes had lower amplitude log SNR (0.49 ± 0.16 vs. 0.56 ± 0.15, P < 0.01), which lost significance (P = 0.51) after adjusting for MD and PSD. Although eyes with ßPPA had significantly lower amplitudes and prolonged latencies than eyes without ßPPA, these differences were attributable to differences in SAP severity, age, and refractive error. Thus, ßPPA does not appear to be an independent factor affecting mfVEP responses in eyes with GON.

  11. Age-related changes in optical and biometric characteristics of emmetropic eyes.

    PubMed

    Atchison, David A; Markwell, Emma L; Kasthurirangan, Sanjeev; Pope, James M; Smith, George; Swann, Peter G

    2008-04-28

    We measured optical and biometric parameters of emmetropic eyes as a function of age. There were approximately 20 subjects each in age groups 18-29, 30-39, 40-49, 50-59, and 60-69 years with similar male and female numbers. One eye was tested for each subject, having spherical equivalent in the range -0.88 D to +0.75 D and eye length increased 0.011 mm/year, anterior lens radius of curvature decreased 0.044 mm/year, and lens equivalent refractive index decreased 0.0003/year. Males had higher anterior corneal radii of curvature (0.16 mm), lower lens equivalent refractive index (0.006), longer vitreous lengths (0.51 mm), and longer axial lengths (0.62 mm) than females. Superficially, the results suggest that eyes get bigger as they age. However, results can be related to refraction patterns in which refraction is stable in 20s to 40s and then moves in the hypermetropic direction. It is likely that several young subjects will become hypermetropic as they age, and it is possible that some of the older subjects were myopic when younger.

  12. Myopic Maculopathy and Optic Disc Changes in Highly Myopic Young Asian Eyes and Impact on Visual Acuity.

    PubMed

    Koh, Victor; Tan, Colin; Tan, Pei Ting; Tan, Marcus; Balla, Vinay; Nah, Gerard; Cheng, Ching-Yu; Ohno-Matsui, Kyoko; Tan, Mellisa M H; Yang, Adeline; Zhao, Paul; Wong, Tien Yin; Saw, Seang-Mei

    2016-04-01

    To determine the prevalence and risk factors of myopic maculopathy and specific optic disc and macular changes in highly myopic eyes of young Asian adults and their impact on visual acuity. Prospective cross-sectional study. In total, 593 highly myopic (spherical equivalent refraction [SER] less than -6.00 diopters [D]) and 156 emmetropic (SER between -1.00 and +1.00 D) male participants from a population-based survey were included. All participants underwent standardized medical interviews, ophthalmic examination, and color fundus photographs. These photographs were graded systematically to determine the presence of optic disc and macular lesions. Myopic maculopathy was classified based on the International Classification of Myopic Maculopathy. The mean age was 21.1 ± 1.2 years. The mean SER for the highly myopic and emmetropic group was -8.87 ± 2.11 D and 0.40 ± 0.39 D, respectively (P < .001). Compared to emmetropic eyes, highly myopic eyes were significantly more likely to have optic disc tilt, peripapillary atrophy (PPA), posterior staphyloma, chorioretinal atrophy, and myopic maculopathy (all P < .001). The main findings included PPA (98.3%), disc tilt (22.0%), posterior staphyloma (32.0%), and chorioretinal atrophy (8.3%). Myopic maculopathy was present in 8.3% of highly myopic eyes and was associated with older age (odds ratio [OR] 1.66; 95% CI: 1.22, 2.26), reduced choroidal thickness (OR 0.99; 95% CI: 0.98, 0.99), and increased axial length (AL) (OR 1.52; 95% CI: 1.06, 2.19). The presence of disc tilt, posterior staphyloma, and chorioretinal atrophy were associated with reduced visual acuity. Our study showed that myopia-related changes of the optic disc and macula were common in highly myopic eyes even at a young age. The risk factors for myopic maculopathy include increased age, longer AL, and reduced choroidal thickness. Some of these changes were associated with reduced central visual function. Copyright © 2016 Elsevier Inc. All rights

  13. Effect of optical aberrations on intraocular pressure measurements using a microscale optical implant in ex vivo rabbit eyes

    NASA Astrophysics Data System (ADS)

    Han, Samuel J.; Park, Haeri; Lee, Jeong Oen; Choo, Hyuck

    2018-04-01

    Elevated intraocular pressure (IOP) is the only modifiable major risk factor of glaucoma. Recently, accurate and continuous IOP monitoring has been demonstrated in vivo using an implantable sensor based on optical resonance with remote optical readout to improve patient outcomes. Here, we investigate the relationship between optical aberrations of ex vivo rabbit eyes and the performance of the IOP sensor using a custom-built setup integrated with a Shack-Hartmann sensor. The sensor readouts became less accurate as the aberrations increased in magnitude, but they remained within the clinically acceptable range. For root-mean-square wavefront errors of 0.10 to 0.94 μm, the accuracy and the signal-to-noise ratio were 0.58 ± 0.32 mm Hg and 15.57 ± 4.85 dB, respectively.

  14. Volatile-nanoparticle-assisted optical visualization of individual carbon nanotubes and other nanomaterials

    NASA Astrophysics Data System (ADS)

    Jian, Muqiang; Xie, Huanhuan; Wang, Qi; Xia, Kailun; Yin, Zhe; Zhang, Mingyu; Deng, Ningqin; Wang, Luning; Ren, Tianling; Zhang, Yingying

    2016-07-01

    The development of nanomaterials has put forward high requirements for characterization techniques. Optical microscopy (OM), with easy accessibility and open operating spaces as compared to scanning electron microscopy, is a good choice to quickly locate materials and to be integrated with other equipment. However, OM is limited by its low resolution. Herein, we present a facile and non-destructive approach for optical observation of nanomaterials under conventional OMs with the aid of volatile nanoparticles (NPs), which can be deposited and removed in a controlled manner. The NPs deposited on the surface of nanomaterials render strong light scattering to enable the nanomaterials to become optically visible. For example, this approach enables the observation of individual carbon nanotubes (CNTs) with OMs at low magnification or even with the naked eye. Both supported CNTs on various substrates and suspended CNTs can be observed with this approach. Most importantly, the NPs can be completely removed through moderate heat treatment or laser irradiation, avoiding potential influence on the properties or subsequent applications of nanomaterials. Furthermore, we systematically investigate the deposition of various volatile NPs (up to 14 kinds) for the optical observation of nanomaterials. We also demonstrated the application of this approach on other nanomaterials, including nanowires and graphene. We showed that this approach is facile, controllable, non-destructive, and contamination-free, indicating wide potential applications.The development of nanomaterials has put forward high requirements for characterization techniques. Optical microscopy (OM), with easy accessibility and open operating spaces as compared to scanning electron microscopy, is a good choice to quickly locate materials and to be integrated with other equipment. However, OM is limited by its low resolution. Herein, we present a facile and non-destructive approach for optical observation of

  15. There may be more to reaching than meets the eye: re-thinking optic ataxia.

    PubMed

    Jackson, Stephen R; Newport, Roger; Husain, Masud; Fowlie, Jane E; O'Donoghue, Michael; Bajaj, Nin

    2009-05-01

    Optic ataxia (OA) is generally thought of as a disorder of visually guided reaching movements that cannot be explained by any simple deficit in visual or motor processing. In this paper we offer a new perspective on optic ataxia; we argue that the popular characterisation of this disorder is misleading and is unrepresentative of the pattern of reaching errors typically observed in OA patients. We begin our paper by reviewing recent neurophysiological, neuropsychological, and functional brain imaging studies that have led to the proposal that the medial parietal cortex in the vicinity of the parietal-occipital junction (POJ) - the key anatomical site associated with OA - represents reaching movements in eye-centred coordinates, and that this ability is impaired in optic ataxia. Our perspective stresses the importance of the POJ and superior parietal regions of the human PPC for representing reaching movements in both extrinsic (eye-centred) and intrinsic (postural) coordinates, and proposes that it is the ability to simultaneously represent multiple spatial locations that must be directly compared with one another that is impaired in non-foveal OA patients. In support of this idea we review recent fMRI and behavioural studies conducted by our group that have investigated the anatomical correlates of posturally guided movements, and the movements guided by postural cues in patients presenting with optic ataxia.

  16. Assessment of the posterior segment of the cat eye by optical coherence tomography (OCT).

    PubMed

    Gekeler, Florian; Gmeiner, Helmut; Völker, Michael; Sachs, Helmut; Messias, Andre; Eule, Corinna; Bartz-Schmidt, Karl Ulrich; Zrenner, Eberhart; Shinoda, Kei

    2007-01-01

    To assess the feasibility of optical coherence tomography (OCT) for examining the cat ocular fundus, to provide normative data on retinal thickness in different fundus regions, and to demonstrate selected surgically induced vitreoretinal pathologies in the cat. Forty-five eyes of 28 healthy domestic cats and two eyes of domestic cats that had undergone subretinal implantation surgery for a visual prosthesis were examined. An optical coherence tomograph (Zeiss-Humphrey) was used to examine the anesthetized animals. At least five vertical and five horizontal scans in regular distribution were recorded for each cat including (1) the peripapillary region, (2) the area centralis, and (3) the peripheral retina. Thickness was measured manually at five locations in each scan. Retinal thickness was compared in the three above-mentioned fundus regions, between eyes and between vertical and horizontal scans. OCT was additionally performed in animals with retinal detachment and a subretinal visual prosthesis. OCT measurements required only minimal adjustments of human settings and yielded high quality images. In comparison to humans intraretinal layers were more difficult to differentiate. Retinal thickness was highest in the peripapillary region (245 +/- 21 microm), followed by the peripheral retina (204 +/- 11 microm) and the area centralis (182 +/- 11 microm; all P < 0.0001). There was no statistically significant difference between right and left eye or between vertical and horizontal scans. OCT demonstrated retinal detachment, an iatrogenic break and a subretinal prosthetic device in high detail. Retinal thickness was measurable with high precision; values compare well to older histologic studies. OCT bears significant advantages over histology in enabling one to repeat measurements in living animals and thus allowing longitudinal studies. Various vitreoretinal pathologies common in feline eyes are detectable and quantifiable by OCT.

  17. Comparison of EyeCam and anterior segment optical coherence tomography in detecting angle closure.

    PubMed

    Baskaran, Mani; Aung, Tin; Friedman, David S; Tun, Tin A; Perera, Shamira A

    2012-12-01

    To compare the diagnostic performance of EyeCam (Clarity Medical Systems, Pleasanton, CA, USA) and anterior segment optical coherence tomography (ASOCT, Visante; Carl Zeiss Meditec, Dublin, CA, USA) in detecting angle closure, using gonioscopy as the reference standard. Ninety-eight phakic patients, recruited from a glaucoma clinic, underwent gonioscopy by a single examiner, and EyeCam and ASOCT imaging by another examiner. Another observer, masked to gonioscopy findings, graded EyeCam and ASOCT images. For both gonioscopy and EyeCam, a closed angle in a particular quadrant was defined if the posterior trabecular meshwork was not visible. For ASOCT, angle closure was defined by any contact between the iris and angle anterior to the scleral spur. An eye was diagnosed as having angle closure if ≥2 quadrants were closed. Agreement and area under the receiver operating characteristic curves (AUC) were evaluated. The majority of subjects were Chinese (69/98, 70.4%) with a mean age of 60.6 years. Angle closure was diagnosed in 39/98 (39.8%) eyes with gonioscopy, 40/98 (40.8%) with EyeCam and 56/97 (57.7%) with ASOCT. The agreement (kappa statistic) for angle closure diagnosis for gonioscopy versus EyeCam was 0.89; gonioscopy versus ASOCT and EyeCam versus ASOCT were both 0.56. The AUC for detecting eyes with gonioscopic angle closure with EyeCam was 0.978 (95% CI: 0.93-1.0) and 0.847 (95% CI: 0.76-0.92, p < 0.01) for ASOCT. The diagnostic performance of EyeCam was better than ASOCT in detecting angle closure when gonioscopic grading was used as the reference standard. The agreement between the two imaging modalities was moderate. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  18. Three-dimensional OCT based guinea pig eye model: relating morphology and optics.

    PubMed

    Pérez-Merino, Pablo; Velasco-Ocana, Miriam; Martinez-Enriquez, Eduardo; Revuelta, Luis; McFadden, Sally A; Marcos, Susana

    2017-04-01

    Custom Spectral Optical Coherence Tomography (SOCT) provided with automatic quantification and distortion correction algorithms was used to measure the 3-D morphology in guinea pig eyes (n = 8, 30 days; n = 5, 40 days). Animals were measured awake in vivo under cyclopegia. Measurements showed low intraocular variability (<4% in corneal and anterior lens radii and <8% in the posterior lens radii, <1% interocular distances). The repeatability of the surface elevation was less than 2 µm. Surface astigmatism was the individual dominant term in all surfaces. Higher-order RMS surface elevation was largest in the posterior lens. Individual surface elevation Zernike terms correlated significantly across corneal and anterior lens surfaces. Higher-order-aberrations (except spherical aberration) were comparable with those predicted by OCT-based eye models.

  19. Exploration of peripapillary vessel density in highly myopic eyes with peripapillary intrachoroidal cavitation and its relationship with ocular parameters using optical coherence tomography angiography.

    PubMed

    Chen, Qiuying; He, Jiangnan; Hua, Yihong; Fan, Ying

    2017-12-01

    Identifying changes of peripapillary vessel density in highly myopic eyes with peripapillary intrachoroidal cavitation by optical coherence tomography angiography. To investigate peripapillary vessel density and its relationship with other ocular parameters in highly myopic eyes with peripapillary intrachoroidal cavitation. Hospital-based, cross-sectional study. Thirty-five highly myopic eyes with peripapillary intrachoroidal cavitation, 46 highly myopic eyes without peripapillary intrachoroidal cavitation and 36 normal eyes were included in this study. All participants underwent optical coherence tomography angiography to image the retinal vasculature in the peripapillary areas, including the radial peripapillary capillaries and optic nerve head layer. Correlations between vessel density and ocular metrics were analysed. Peripapillary vessel density. In highly myopic eyes, vessel density was significantly lower in eyes with peripapillary intrachoroidal cavitation than in those without in peripapillary (P = 0.014, P = 0.037), inferotemporal (P < 0.001, P < 0.001) and superotemporal (P = 0.014, P = 0.009) areas. In the radial peripapillary capillaries layer, vessel density was negatively correlated with peripapillary atrophy area (P = 0.012) and myopic maculopathy (P = 0.002), and in the optic nerve head layer, it was negatively associated with a diagnosis of peripapillary intrachoroidal cavitation (P = 0.012) and myopic maculopathy (P < 0.001). In addition, it was positively correlated with retinal nerve fibre layer thickness in both layers (P < 0.001). Highly myopic eyes with peripapillary intrachoroidal cavitation had lower peripapillary vessel densities, especially in the temporal area, than those without. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  20. Integrated Model of the Eye/Optic Nerve Head Biomechanical Environment

    NASA Technical Reports Server (NTRS)

    Ethier, C. R.; Feola, A.; Myers, J. G.; Nelson, E.; Raykin, J.; Samuels, B.

    2017-01-01

    Visual Impairment and Intracranial Pressure (VIIP) syndrome is a concern for long-duration space flight. Previously, it has been suggested that ocular changes observed in VIIP syndrome are related to the cephalad fluid shift that results in altered fluid pressures [1]. We are investigating the impact of changes in intracranial pressure (ICP) using a combination of numerical models, which simulate the effects of various environment conditions, including finite element (FE) models of the posterior eye. The specific interest is to understand how altered pressures due to gravitational changes affect the biomechanical environment of tissues of the posterior eye and optic nerve sheath. METHODS: Additional description of the numerical modeling is provided in the IWS abstract by Nelson et al. In brief, to simulate the effects of a cephalad fluid shift on the cardiovascular and ocular systems, we utilized a lumped-parameter compartment model of these systems. The outputs of this lumped-parameter model then inform boundary conditions (pressures) for a finite element model of the optic nerve head (Figure 1). As an example, we show here a simulation of postural change from supine to 15 degree head-down tilt (HDT), with primary outcomes being the predicted change in strains at the optic nerve head (ONH) region, specifically in the lamina cribrosa (LC), retrolaminar optic nerve, and prelaminar neural tissue (PLNT). The strain field can be decomposed into three orthogonal components, denoted as the first, second and third principal strains. We compare the peak tensile (first principal) and compressive (third principal) strains, since elevated strain alters cell phenotype and induces tissue remodeling. RESULTS AND CONCLUSIONS: Our lumped-parameter model predicted an IOP increase of c. 7 mmHg after 21 minutes of 15 degree HDT, which agreed with previous reports of IOP in HDT [1]. The corresponding FEM simulations predicted a relative increase in the magnitudes of the peak tensile

  1. Flash fire propensity of materials

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Cumming, H. J.

    1977-01-01

    Flash fire test results on 86 materials, evaluated using the USF flash fire screening test, are presented. The materials which appear least prone to flash fires are PVC, polyphenylene oxide and sulfide, and polyether and polyaryl sulfone; these did not produce flash fires under these particular test conditions. The principal value of these screening tests at the present time is in identifying materials which appear prone to flash fires, and in identifying which formulations of a generic material are more or less prone to flash fires.

  2. A selective naked-eye chemosensor derived from 2-methoxybenzylamine and 2,3-dihydroxybenzaldehyde - synthesis, spectral characterization and electrochemistry of its bis-bidentates Schiff bases metal complexes

    NASA Astrophysics Data System (ADS)

    Djouhra, Aggoun; Ali, Ourari; Ramiro, Ruiz-Rosas; Emilia, Morallon

    2017-09-01

    A new colorimetric receptor HL, acting as a bidentate Schiff base ligand, has been synthesized by condensation of 2-methoxybenzylamine on 2,3-dihydroxybenzaldehyde in a methanolic solution. Interestingly, this chelating agent can selectively detect Cu2 +, Co2 +, Fe2 + and Fe3 + ions with a simple and an easy-to-make, well defined naked-eye visible color changes in two different solvents like acetonitrile and methanol. This bidentate ligand coordinates three metal ions of Co(II), Cu(II) and Fe(II) via nitrogen and oxygen atoms. The molecular structures of the synthesized compounds were elucidated by various physicochemical properties such as the elemental analysis, FT-IR, HNMR, UV-Vis and the Mass spectrometry. The resulting general formulae [M(L)2·H2O] (M(II) = Cu, Fe, Co) are proposed as mononuclear complexes. The solvatochromism properties of these compounds were studied with their absorption spectra using different solvents as methanol (MeOH), acetonitrile (AN), tetrahydrofuran (THF), dimethylformamid (DMF), dimethylsulfoxid (DMSO) and dichloromethane (DC). The Electrochemical behavior of copper complex was explored in DMF solutions by cyclic voltammetry (CV) with two working electrodes: glassy carbon (GC) and platinum electrode (Pt). This study reveals that copper complex shows successively two redox systems as CuIII/II and CuII/I. The FeIII/II and CoII/I redox systems have also been studied in DMF and DMSO media.

  3. Imaging slit-coupled surface plasmon polaritons using conventional optical microscopy.

    PubMed

    Mehfuz, R; Chowdhury, F A; Chau, K J

    2012-05-07

    We develop a technique that now enables surface plasmon polaritons (SPPs) coupled by nano-patterned slits in a metal film to be detected using conventional optical microscopy with standard objective lenses. The crux of this method is an ultra-thin polymer layer on the metal surface, whose thickness can be varied over a nanoscale range to enable controllable tuning of the SPP momentum. At an optimal layer thickness for which the SPP momentum matches the momentum of light emerging from the slit, the SPP coupling efficiency is enhanced about six times relative to that without the layer. The enhanced efficiency results in distinctive and bright plasmonic signatures near the slit visible by naked eye under an optical microscope. We demonstrate how this capability can be used for parallel measurement through a simple experiment in which the SPP propagation distance is extracted from a single microscope image of an illuminated array of nano-patterned slits on a metal surface. We also use optical microscopy to image the focal region of a plasmonic lens and obtain results consistent with a previously-reported results using near-field optical microscopy. Measurement of SPPs near a nano-slit using conventional and widely-available optical microscopy is an important step towards making nano-plasmonic device technology highly accessible and easy-to-use.

  4. Novel short-pulse laser diode source for high-resolution 3D flash lidar

    NASA Astrophysics Data System (ADS)

    Canal, Celine; Laugustin, Arnaud; Kohl, Andreas; Rabot, Olivier

    2017-06-01

    Imaging based on laser illumination is present in various fields of applications such as medicine, security, defense, civil engineering and in the automotive sector. In this last domain, research and development to bring autonomous vehicles on the roads has been intensified the recent years. Among the various technologies currently studied, automotive lidars are a fast-growing one due to their accuracy to detect a wide range of objects at distances up to a few hundreds of meters in various weather conditions. First commercialized devices for ADAS were laser scanners. Since then, new architectures have recently appeared such as solid-state lidar and flash lidar that offer a higher compactness, robustness and a cost reduction. Flash lidars are based on time-of-flight measurements, with the particularity that they do not require beam scanners because only one short laser pulse with a large divergence is used to enlighten the whole scene. Depth of encountered objects can then be recovered from measurement of echoed light at once, hence enabling real-time 3D mapping of the environment. This paper will bring into the picture a cutting edge laser diode source that can deliver millijoule pulses as short as 12 ns, which makes them highly suitable for integration in flash lidars. They provide a 100-kW peak power highly divergent beam in a footprint of 4x5 cm2 (including both the laser diode and driver) and with a 30-% electrical-to-optical efficiency, making them suitable for integration in environments in which compactness and power consumption are a priority. Their emission in the range of 800-1000 nm is considered to be eye safe when taking into account the high divergence of the output beam. An overview of architecture of these state-of-the-art pulsed laser diode sources will be given together with some solutions for their integration in 3D mapping systems. Future work leads will be discussed for miniaturization of the laser diode and drastic cost reduction.

  5. Eye morphogenesis driven by epithelial flow into the optic cup facilitated by modulation of bone morphogenetic protein

    PubMed Central

    Heermann, Stephan; Schütz, Lucas; Lemke, Steffen; Krieglstein, Kerstin; Wittbrodt, Joachim

    2015-01-01

    The hemispheric, bi-layered optic cup forms from an oval optic vesicle during early vertebrate eye development through major morphological transformations. The overall basal surface, facing the developing lens, is increasing, while, at the same time, the space basally occupied by individual cells is decreasing. This cannot be explained by the classical view of eye development. Using zebrafish (Danio rerio) as a model, we show that the lens-averted epithelium functions as a reservoir that contributes to the growing neuroretina through epithelial flow around the distal rims of the optic cup. We propose that this flow couples morphogenesis and retinal determination. Our 4D data indicate that future stem cells flow from their origin in the lens-averted domain of the optic vesicle to their destination in the ciliary marginal zone. BMP-mediated inhibition of the flow results in ectopic neuroretina in the RPE domain. Ultimately the ventral fissure fails to close resulting in coloboma. DOI: http://dx.doi.org/10.7554/eLife.05216.001 PMID:25719386

  6. Escaping compound eye ancestry: the evolution of single-chamber eyes in holometabolous larvae.

    PubMed

    Buschbeck, Elke K

    2014-08-15

    Stemmata, the eyes of holometabolous insect larvae, have gained little attention, even though they exhibit remarkably different optical solutions, ranging from compound eyes with upright images, to sophisticated single-chamber eyes with inverted images. Such optical differences raise the question of how major transitions may have occurred. Stemmata evolved from compound eye ancestry, and optical differences are apparent even in some of the simplest systems that share strong cellular homology with adult ommatidia. The transition to sophisticated single-chamber eyes occurred many times independently, and in at least two different ways: through the fusion of many ommatidia [as in the sawfly (Hymenoptera)], and through the expansion of single ommatidia [as in tiger beetles (Coleoptera), antlions (Neuroptera) and dobsonflies (Megaloptera)]. Although ommatidia-like units frequently have multiple photoreceptor layers (tiers), sophisticated image-forming stemmata tend to only have one photoreceptor tier, presumably a consequence of the lens only being able to efficiently focus light on to one photoreceptor layer. An interesting exception is found in some diving beetles [Dytiscidae (Coleoptera)], in which two retinas receive sharp images from a bifocal lens. Taken together, stemmata represent a great model system to study an impressive set of optical solutions that evolved from a relatively simple ancestral organization. © 2014. Published by The Company of Biologists Ltd.

  7. Fast ray-tracing of human eye optics on Graphics Processing Units.

    PubMed

    Wei, Qi; Patkar, Saket; Pai, Dinesh K

    2014-05-01

    We present a new technique for simulating retinal image formation by tracing a large number of rays from objects in three dimensions as they pass through the optic apparatus of the eye to objects. Simulating human optics is useful for understanding basic questions of vision science and for studying vision defects and their corrections. Because of the complexity of computing such simulations accurately, most previous efforts used simplified analytical models of the normal eye. This makes them less effective in modeling vision disorders associated with abnormal shapes of the ocular structures which are hard to be precisely represented by analytical surfaces. We have developed a computer simulator that can simulate ocular structures of arbitrary shapes, for instance represented by polygon meshes. Topographic and geometric measurements of the cornea, lens, and retina from keratometer or medical imaging data can be integrated for individualized examination. We utilize parallel processing using modern Graphics Processing Units (GPUs) to efficiently compute retinal images by tracing millions of rays. A stable retinal image can be generated within minutes. We simulated depth-of-field, accommodation, chromatic aberrations, as well as astigmatism and correction. We also show application of the technique in patient specific vision correction by incorporating geometric models of the orbit reconstructed from clinical medical images. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Balance of corneal horizontal coma by internal optics in eyes with intraocular artificial lenses: evidence of a passive mechanism.

    PubMed

    Marcos, Susana; Rosales, Patricia; Llorente, Lourdes; Barbero, Sergio; Jiménez-Alfaro, I

    2008-01-01

    It is well known that the aberrations of the cornea are partially compensated by the aberrations of the internal optics of the eye (primarily the crystalline lens) in young subjects. This effect has been found not only for the spherical aberration, but also for horizontal coma. It has been debated whether the compensation of horizontal coma is the result of passive mechanism [Artal, P., Benito, A., & Tabernero, J. (2006). The human eye is an example of robust optical design. Journal of Vision, 6 (1), 1-7] or through an active developmental feedback process [Kelly, J. E., Mihashi, T., & Howland, H. C. (2004). Compensation of corneal horizontal/vertical astigmatism, lateral coma, and spherical aberration by internal optics of the eye. Journal of Vision, 4 (4), 262-271]. In this study we investigate the active or passive nature of the horizontal coma compensation using eyes with artificial lenses, where no active developmental process can be present. We measured total and corneal aberrations, and lens tilt and decentration in a group of 38 eyes implanted with two types of intraocular lenses designed to compensate the corneal spherical aberration of the average population. We found that spherical aberration was compensated by 66%, and horizontal coma by 87% on average. The spherical aberration is not compensated at an individual level, but horizontal coma is compensated individually (coefficients of correlation corneal/internal aberration: -0.946, p<0.0001). The fact that corneal (but not total) horizontal coma is highly correlated with angle lamda (computed from the shift of the 1st Purkinje image from the pupil center, for foveal fixation) indicates that the compensation arises primarily from the geometrical configuration of the eye (which generates horizontal coma of opposite signs in the cornea and internal optics). The amount and direction of tilts and misalignments of the lens are comparable to those found in young eyes, and on average tend to compensate (rather

  9. Daily Physical Activity and Hot Flashes in the Study of Women's Health Across the Nation FLASHES Study

    PubMed Central

    Gibson, Carolyn; Matthews, Karen; Thurston, Rebecca

    2014-01-01

    Objective To examine the role of physical activity in menopausal hot flashes. Competing models conceptualize physical activity as a risk or protective factor for hot flashes. Few studies have examined this relationship prospectively using physiologic measures of hot flashes and physical activity. Design Over two 48 hour-periods, 51 participants wore a physiologic hot flash monitor and activity monitor, and reported their hot flashes in an electronic diary. Physiologic hot flashes, reported hot flashes and reported hot flashes without physiological corroboration were related to activity changes using hierarchical generalized linear modeling, adjusting for potential confounders. Setting Community. Patients Midlife women. Interventions None. Main Outcome Measures Physiologically-detected hot flashes and reported hot flashes with and without physiologic corroboration. Results Hot flash reports without physiologic corroboration were more likely after activity increases (OR 1.04, 95% CI: 1.00-1.10, p=.01), particularly among women with higher levels of depressive symptoms (interaction p=.02). No other types of hot flashes were related to physical activity. Conclusion Acute increases in physical activity were associated with increased reporting of hot flashes lacking physiologic corroboration, particularly among women with depressive symptoms. Clinicians should consider the role of symptom perception and reporting in relations between physical activity and hot flashes. PMID:24491454

  10. Active Flash: Out-of-core Data Analytics on Flash Storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boboila, Simona; Kim, Youngjae; Vazhkudai, Sudharshan S

    2012-01-01

    Next generation science will increasingly come to rely on the ability to perform efficient, on-the-fly analytics of data generated by high-performance computing (HPC) simulations, modeling complex physical phenomena. Scientific computing workflows are stymied by the traditional chaining of simulation and data analysis, creating multiple rounds of redundant reads and writes to the storage system, which grows in cost with the ever-increasing gap between compute and storage speeds in HPC clusters. Recent HPC acquisitions have introduced compute node-local flash storage as a means to alleviate this I/O bottleneck. We propose a novel approach, Active Flash, to expedite data analysis pipelines bymore » migrating to the location of the data, the flash device itself. We argue that Active Flash has the potential to enable true out-of-core data analytics by freeing up both the compute core and the associated main memory. By performing analysis locally, dependence on limited bandwidth to a central storage system is reduced, while allowing this analysis to proceed in parallel with the main application. In addition, offloading work from the host to the more power-efficient controller reduces peak system power usage, which is already in the megawatt range and poses a major barrier to HPC system scalability. We propose an architecture for Active Flash, explore energy and performance trade-offs in moving computation from host to storage, demonstrate the ability of appropriate embedded controllers to perform data analysis and reduction tasks at speeds sufficient for this application, and present a simulation study of Active Flash scheduling policies. These results show the viability of the Active Flash model, and its capability to potentially have a transformative impact on scientific data analysis.« less

  11. Eyes with Suspicious Appearance of the Optic Disc and Normal Intraocular Pressure: Using Clinical and Epidemiological Characteristics to Differentiate Those with and without Glaucoma.

    PubMed

    Dias, Diego T; Ushida, Michele; Sousa, Marina C; Dorairaj, Syril; Biteli, Luis G; Leite, Mauro T; Paranhos, Augusto; Prata, Tiago S

    2016-01-01

    Among all glaucoma suspects, eyes with optic nerve head features suspicious or suggestive of early glaucoma are probably those that offer the greatest challenge for clinicians. In contrast with the robust longitudinal data published on ocular hypertension, there is no specific management guideline for these patients. Therefore, evaluating eyes with suspicious optic disc appearance and normal intraocular pressure (IOP), we sought to investigate potential differences in clinical and epidemiological characteristics to differentiate those with normal-tension glaucoma (NTG) from those with presumed large physiological optic disc cups (pLPC). In this observational case-control study, we consecutively enrolled individuals with pLPC and NTG. All eyes had vertical cup-to-disc ratio (VCDR)≥0.6 and untreated IOP<21 mmHg. Glaucomatous eyes had reproducible visual field defects. Eyes with pLPC required normal visual fields and ≥30 months of follow-up with no evidence of glaucomatous neuropathy. Clinical and epidemiological parameters were compared between groups. Eighty-four individuals with pLPC and 40 NTG patients were included. Regarding our main results, NTG patients were significantly older and with a higher prevalence of Japanese descendants (p<0.01). Not only did pLPC eyes have smaller mean VCDR, but also larger optic discs (p≤0.04). There were no significant differences for gender, central corneal thickness, and spherical equivalent (p≥0.38). Significant odds ratios (OR) were found for race (OR = 2.42; for Japanese ancestry), age (OR = 1.05), VCDR (OR = 5.03), and disc size (OR = 0.04; p≤0.04). In conclusion, in patients with suspicious optic disc and normal IOP, those with older age, Japanese ancestry, smaller optic discs, and larger VCDR are more likely to have NTG, and therefore, deserve deeper investigation and closer monitoring.

  12. Naked-eye” colorimetric and “turn-on” fluorometric chemosensors for reversible Hg2+ detection

    NASA Astrophysics Data System (ADS)

    Wanichacheva, Nantanit; Praikaew, Panida; Suwanich, Thanapat; Sukrat, Kanjarat

    2014-01-01

    Two new Hg2+-colorimetric and fluorescent sensors based on 2-[3-(2-aminoethylsulfanyl) propylsulfanyl]ethanamine covalently bound to one and two units of rhodamine-6G moieties, 1 and 2, were synthesised, and their sensing behaviors toward metal ions were investigated by UV/Vis and fluorescence spectroscopy. Upon the addition of Hg2+, the sensors exhibited highly sensitive “turn-on” fluorescence enhancement as well as a color change from colorless to pink, which was readily noticeable for naked eye detection. Especially, 1 exhibited the reversible behavior and revealed a very high selectivity in the presence of competitive ions, particularly Cu2+, Ag+, Pb2+, Ca2+, Cd2+, Co2+, Fe2+, Mn2+, Na+, Ni2+, K+, Ba2+, Li+ and Zn2+, with a low detection limit of 1.7 ppb toward Hg2+.

  13. Menopausal hot flashes: Randomness or rhythmicity

    NASA Astrophysics Data System (ADS)

    Kronenberg, Fredi

    1991-10-01

    Menopausal hot flashes are episodes of flushing, increased heart rate, skin blood flow and skin temperature, and a sensation of heat. The thermoregulatory and cardiovascular concomitants of hot flashes are associated with peaks in the levels of various hormones and neurotransmitters in the peripheral circulation. Although hot flashes affect about 75% of women, and are the primary reason that women at menopause seek medical attention, the mechanism of hot flashes is still not understood. Hot flashes vary in frequency and intensity both within and between individuals, and have been thought of as occurring randomly. Yet, some women report that their hot flashes are worse at a particular time of day or year. Initial examination of subjects' recordings of their hot flashes showed diurnal patterns of hot flash occurrence. There also seems to be a diurnal rhythm of hot flash intensity. Continuous physiological monitoring of hot flashes is facilitating the analysis of these patterns, which is revealing circadian and ultradian periodicities. The occurrence of hot flashes can be modulated by external and internal factors, including ambient temperature and fever. Rhythms of thermoregulatory and endocrine functions also may influence hot flash patterns. Examination of the interrelationships between the various systems of the body involved in hot flashes, and a multidisciplinary approach to the analysis of hot flash patterns, will aid our understanding of this complex phenomenon.

  14. Kin discrimination and female mate choice in the naked mole-rat Heterocephalus glaber.

    PubMed

    Clarke, F M; Faulkes, C G

    1999-10-07

    Naked mole-rats are fossorial, eusocial rodents that naturally exhibit high levels of inbreeding. Persistent inbreeding in animals often results in a substantial decline in fitness and, thus, dispersal and avoidance of kin as mates are two common inbreeding avoidance mechanisms. In the naked mole-rat evidence for the former has recently been found. Here we address the latter mechanism by investigating kin recognition and female mate choice using a series of choice tests in which the odour, social and mate preferences of females were determined. Discrimination by females appears to be dependent on their reproductive status. Reproductively active females prefer to associate with unfamiliar males, whereas reproductively inactive females do not discriminate. Females do not discriminate between kin and non-kin suggesting that the criterion for recognition is familiarity, not detection of genetic similarity per se. In the wild, naked mole-rats occupy discrete burrow systems and dispersal and mixing with non-kin is thought to be comparatively rare. Thus, recognition by familiarity may function as a highly efficient kin recognition mechanism in the naked mole-rat. A preference by reproductively active females for unfamiliar males is interpreted as inbreeding avoidance. These findings suggest that, despite an evolutionary history of close inbreeding, naked mole-rats may not be exempt from the effects of inbreeding depression and will attempt to outbreed should the opportunity arise.

  15. High temporal resolution aberrometry in a 50-eye population and implications for adaptive optics error budget.

    PubMed

    Jarosz, Jessica; Mecê, Pedro; Conan, Jean-Marc; Petit, Cyril; Paques, Michel; Meimon, Serge

    2017-04-01

    We formed a database gathering the wavefront aberrations of 50 healthy eyes measured with an original custom-built Shack-Hartmann aberrometer at a temporal frequency of 236 Hz, with 22 lenslets across a 7-mm diameter pupil, for a duration of 20 s. With this database, we draw statistics on the spatial and temporal behavior of the dynamic aberrations of the eye. Dynamic aberrations were studied on a 5-mm diameter pupil and on a 3.4 s sequence between blinks. We noted that, on average, temporal wavefront variance exhibits a n -2 power-law with radial order n and temporal spectra follow a f -1.5 power-law with temporal frequency f . From these statistics, we then extract guidelines for designing an adaptive optics system. For instance, we show the residual wavefront error evolution as a function of the number of corrected modes and of the adaptive optics loop frame rate. In particular, we infer that adaptive optics performance rapidly increases with the loop frequency up to 50 Hz, with gain being more limited at higher rates.

  16. High temporal resolution aberrometry in a 50-eye population and implications for adaptive optics error budget

    PubMed Central

    Jarosz, Jessica; Mecê, Pedro; Conan, Jean-Marc; Petit, Cyril; Paques, Michel; Meimon, Serge

    2017-01-01

    We formed a database gathering the wavefront aberrations of 50 healthy eyes measured with an original custom-built Shack-Hartmann aberrometer at a temporal frequency of 236 Hz, with 22 lenslets across a 7-mm diameter pupil, for a duration of 20 s. With this database, we draw statistics on the spatial and temporal behavior of the dynamic aberrations of the eye. Dynamic aberrations were studied on a 5-mm diameter pupil and on a 3.4 s sequence between blinks. We noted that, on average, temporal wavefront variance exhibits a n−2 power-law with radial order n and temporal spectra follow a f−1.5 power-law with temporal frequency f. From these statistics, we then extract guidelines for designing an adaptive optics system. For instance, we show the residual wavefront error evolution as a function of the number of corrected modes and of the adaptive optics loop frame rate. In particular, we infer that adaptive optics performance rapidly increases with the loop frequency up to 50 Hz, with gain being more limited at higher rates. PMID:28736657

  17. Gravitational radiation from a cylindrical naked singularity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakao, Ken-ichi; Morisawa, Yoshiyuki

    We construct an approximate solution which describes the gravitational emission from a naked singularity formed by the gravitational collapse of a cylindrical thick shell composed of dust. The assumed situation is that the collapsing speed of the dust is very large. In this situation, the metric variables are obtained approximately by a kind of linear perturbation analysis in the background Morgan solution which describes the motion of cylindrical null dust. The most important problem in this study is what boundary conditions for metric and matter variables should be imposed at the naked singularity. We find a boundary condition that allmore » the metric and matter variables are everywhere finite at least up to the first order approximation. This implies that the spacetime singularity formed by this high-speed dust collapse is very similar to that formed by the null dust and the final singularity will be a conical one. Weyl curvature is completely released from the collapsed dust.« less

  18. Why Flash Type Matters: A Statistical Analysis

    NASA Astrophysics Data System (ADS)

    Mecikalski, Retha M.; Bitzer, Phillip M.; Carey, Lawrence D.

    2017-09-01

    While the majority of research only differentiates between intracloud (IC) and cloud-to-ground (CG) flashes, there exists a third flash type, known as hybrid flashes. These flashes have extensive IC components as well as return strokes to ground but are misclassified as CG flashes in current flash type analyses due to the presence of a return stroke. In an effort to show that IC, CG, and hybrid flashes should be separately classified, the two-sample Kolmogorov-Smirnov (KS) test was applied to the flash sizes, flash initiation, and flash propagation altitudes for each of the three flash types. The KS test statistically showed that IC, CG, and hybrid flashes do not have the same parent distributions and thus should be separately classified. Separate classification of hybrid flashes will lead to improved lightning-related research, because unambiguously classified hybrid flashes occur on the same order of magnitude as CG flashes for multicellular storms.

  19. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes.

    PubMed

    Mao, Xinjie; Banta, James T; Ke, Bilian; Jiang, Hong; He, Jichang; Liu, Che; Wang, Jianhua

    2016-01-01

    To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor. Twenty-eight adult subjects (32 pseudophakic eyes) having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR) and intraclass correlation coefficient (ICC) were calculated. Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951. The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye.

  20. Bio-inspired hemispherical compound eye camera

    NASA Astrophysics Data System (ADS)

    Xiao, Jianliang; Song, Young Min; Xie, Yizhu; Malyarchuk, Viktor; Jung, Inhwa; Choi, Ki-Joong; Liu, Zhuangjian; Park, Hyunsung; Lu, Chaofeng; Kim, Rak-Hwan; Li, Rui; Crozier, Kenneth B.; Huang, Yonggang; Rogers, John A.

    2014-03-01

    Compound eyes in arthropods demonstrate distinct imaging characteristics from human eyes, with wide angle field of view, low aberrations, high acuity to motion and infinite depth of field. Artificial imaging systems with similar geometries and properties are of great interest for many applications. However, the challenges in building such systems with hemispherical, compound apposition layouts cannot be met through established planar sensor technologies and conventional optics. We present our recent progress in combining optics, materials, mechanics and integration schemes to build fully functional artificial compound eye cameras. Nearly full hemispherical shapes (about 160 degrees) with densely packed artificial ommatidia were realized. The number of ommatidia (180) is comparable to those of the eyes of fire ants and bark beetles. The devices combine elastomeric compound optical elements with deformable arrays of thin silicon photodetectors, which were fabricated in the planar geometries and then integrated and elastically transformed to hemispherical shapes. Imaging results and quantitative ray-tracing-based simulations illustrate key features of operation. These general strategies seem to be applicable to other compound eye devices, such as those inspired by moths and lacewings (refracting superposition eyes), lobster and shrimp (reflecting superposition eyes), and houseflies (neural superposition eyes).

  1. Temporal characterization of small arms muzzle flash in the broadband visible

    NASA Astrophysics Data System (ADS)

    Burke, Tom; Bratlie, Duane

    2010-04-01

    The authors have developed a simple system for characterizing the muzzle flash duration of common military small-arms ammunition as a feeder for system design configurations. This paper is a synopsis of the efforts and results of the effort to characterize the broadband optical signature of modern small arms.

  2. Bias-corrected diagnostic performance of the naked-eye single-tube red-cell osmotic fragility test (NESTROFT): an effective screening tool for beta-thalassemia.

    PubMed

    Mamtani, Manju; Jawahirani, Anil; Das, Kishor; Rughwani, Vinky; Kulkarni, Hemant

    2006-08-01

    It is being increasingly recognized that a majority of the countries in the thalassemia-belt need a cost-effective screening program as the first step towards control of thalassemia. Although the naked eye single tube red cell osmotic fragility test (NESTROFT) has been considered to be a very effective screening tool for beta-thalassemia trait, assessment of its diagnostic performance has been affected with the reference test- and verification-bias. Here, we set out to provide estimates of sensitivity and specificity of NESTROFT corrected for these potential biases. We conducted a cross-sectional diagnostic test evaluation study using data from 1563 subjects from Central India with a high prevalence of beta-thalassemia. We used latent class modelling after ensuring its validity to account for the reference test bias and global sensitivity analysis to control the verification bias. We also compared the results of latent class modelling with those of five discriminant indexes. We observed that across a range of cut-offs for the mean corpuscular volume (MCV) and the hemoglobin A2 (HbA2) concentration the average sensitivity and specificity of NESTROFT obtained from latent class modelling was 99.8 and 83.7%, respectively. These estimates were comparable to those characterizing the diagnostic performance of HbA2, which is considered by many as the reference test to detect beta-thalassemia. After correction for the verification bias these estimates were 93.4 and 97.2%, respectively. Combined with the inexpensive and quick disposition of NESTROFT, these results strongly support its candidature as a screening tool-especially in the resource-poor and high-prevalence settings.

  3. Efficiency of optical-electronic systems: methods application for the analysis of structural changes in the process of eye grounds diagnosis

    NASA Astrophysics Data System (ADS)

    Saldan, Yosyp R.; Pavlov, Sergii V.; Vovkotrub, Dina V.; Saldan, Yulia Y.; Vassilenko, Valentina B.; Mazur, Nadia I.; Nikolaichuk, Daria V.; Wójcik, Waldemar; Romaniuk, Ryszard; Suleimenov, Batyrbek; Bainazarov, Ulan

    2017-08-01

    Process of eye tomogram obtaining by means of optical coherent tomography is studied. Stages of idiopathic macula holes formation in the process of eye grounds diagnostics are considered. Main stages of retina pathology progression are determined: Fuzzy logic units for obtaining reliable conclusions regarding the result of diagnosis are developed. By the results of theoretical and practical research system and technique of retinal macular region of the eye state analysis is developed ; application of the system, based on fuzzy logic device, improves the efficiency of eye retina complex.

  4. [Macular thickness measured by optical coherence tomography in pseudoaphakic eyes with clear vs yellow implant].

    PubMed

    Chamorro, E; Bonnin-Arias, C; Pérez-Carrasco, M J; Alvarez-Rementería, L; Villa-Collar, C; Armadá-Maresca, F; Sánchez-Ramos, C

    2014-04-01

    To study the use of optical coherence tomography (OCT), for measuring the macular thickness variations produced over time in elderly pseudophakic subjects implanted with a clear intraocular lens (IOL) in one eye, and a yellow IOL in the other eye. Macular thickness measurements were obtained in the 36 eyes of 18 subjects over 65 years, with cataracts surgically removed from both eyes and implanted with different absorbance (clear and yellow) IOLs in 2 separate surgeries. Stratus-OCT was used to determine the macular thickness in 2 sessions with 5 years of difference. After 5 years of follow-up, the eyes implanted with clear IOLs revealed a significant decrease in macular thickness. However, in eyes implanted with yellow IOLs the macular thickness remained stable. The mean overall decrease in macular thickness in eyes implanted with clear IOLs was 5 ± 8 μm (P=.02), and foveal thickness reduction was 10 ± 17 μm (P=.02). The macular thickness changes produced in eyes implanted with a yellow IOL differ from those with a clear IOL. These observation point to a possible protective effect of yellow IOL against the harmful effects of light in elderly pseudophakic subjects. However, studies with a longer follow-up are still needed to confirm that the protection provided by this IOL model is clinically significant. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  5. Optical progression characteristics of an interesting natural downward bipolar lightning flash

    NASA Astrophysics Data System (ADS)

    Chen, Luwen; Lu, Weitao; Zhang, Yijun; Wang, Daohong

    2015-01-01

    high-speed cameras, Lightning Attachment Process Observation Systems, and fast and slow electrical antennas, we documented a downward bipolar lightning flash that contained one first positive stroke with a peak current of 142 kA and five subsequent negative strokes hitting on a 90 m tall structure on 29 July 2010 in Guangzhou City, China. All the six strokes propagated along the same viewed channel established by the first positive return stroke. The leader which preceded the positive return stroke propagated downward without any branches at a two-dimensional (2-D) speed of 2.5 × 106 m/s. An upward connecting leader with a length of about 80 m was observed in response to the downward positive leader. The 10-90% risetimes of the return strokes' optical pulses ranged from 2.2 µs to 3.2 µs, while the widths from the 10% wavefront to the 50% wave tail ranged from 56.5 µs to 83.1 µs, and the half peak widths ranged from 53.4 µs to 81.6 µs. All the return strokes exhibited similar speeds, ranging from 1.0 × 108 m/s to 1.3 × 108 m/s. Each of the return strokes was followed by a continuing current stage (CC). The first positive stroke CC lasted more than 150 ms, much larger than all the subsequent negative stroke CC, ranging from 13 ms to 70 ms.

  6. Pseudo-cat's eye for improved tilt-immune interferometry.

    PubMed

    Speake, Clive C; Bradshaw, Miranda J

    2015-08-20

    We present a new simple optical design for a cat's eye retroreflector. We describe the design of the new optical configuration and its use in tilt-immune interferometry where it enables the tracking of the displacement of a plane target mirror with minimum sensitivity to its tilt about axes orthogonal to the interferometer's optical axis. In this application the new cat's eye does not behave as a perfect retroreflector and we refer to it as a "pseudo"-cat's eye (PCE). The device allows, for the first time, tilt-immune interferometric displacement measurements in cases where the nominal distance to the target mirror is significantly larger than the length of the cat's eye. We describe the general optical characteristics of the PCE and compare its performance in our application with that of a conventional cat's eye optical configuration using ABCD matrices and Zemax analyses. We further suggest a simple modification to the design that would enable the PCE to behave as a perfect cat's eye, and this design may provide an advantageous solution for other applications.

  7. Corneal thickness and elevation measurements using swept-source optical coherence tomography and slit scanning topography in normal and keratoconic eyes.

    PubMed

    Jhanji, Vishal; Yang, Bingzhi; Yu, Marco; Ye, Cong; Leung, Christopher K S

    2013-11-01

    To compare corneal thickness and corneal elevation using swept source optical coherence tomography and slit scanning topography. Prospective study. 41 normal and 46 keratoconus subjects. All eyes were imaged using swept source optical coherence tomography and slit scanning tomography during the same visit. Mean corneal thickness and best-fit sphere measurements were compared between the instruments. Agreement of measurements between swept source optical coherence tomography and scanning slit topography was analyzed. Intra-rater reproducibility coefficient and intraclass correlation coefficient were evaluated. In normal eyes, central corneal thickness measured by swept source optical coherence tomography was thinner compared with slit scanning topography (p < 0.0001) and ultrasound pachymetry (p = < .0001). Ultrasound pachymetry readings had better 95% limits of agreement with swept source optical coherence tomography than slit scanning topography. In keratoconus eyes, central corneal thickness was thinner on swept source optical coherence tomography than slit scanning topography (p = 0.081) and ultrasound pachymetry (p = 0.001). There were significant differences between thinnest corneal thickness, and, anterior and posterior best-fit sphere measurements between both instruments (p < 0.05 for all). Overall, reproducibility coefficients and intraclass correlation coefficients were significantly better with swept source optical coherence tomography for measurement of central corneal thickness, anterior best-fit sphere and, posterior best-fit sphere (all p < 0.001). Corneal thickness and elevation measurements were significantly different between swept source optical coherence tomography and slit scanning topography. With better reproducibility coefficients and intraclass correlation coefficients, swept source optical coherence tomography may provide a reliable alternative for measurement of corneal parameters. © 2013 The Authors. Clinical

  8. Minimizing camera-eye optical aberrations during the 3D reconstruction of retinal structures

    NASA Astrophysics Data System (ADS)

    Aldana-Iuit, Javier; Martinez-Perez, M. Elena; Espinosa-Romero, Arturo; Diaz-Uribe, Rufino

    2010-05-01

    3D reconstruction of blood vessels is a powerful visualization tool for physicians, since it allows them to refer to qualitative representation of their subject of study. In this paper we propose a 3D reconstruction method of retinal vessels from fundus images. The reconstruction method propose herein uses images of the same retinal structure in epipolar geometry. Images are preprocessed by RISA system for segmenting blood vessels and obtaining feature points for correspondences. The correspondence points process is solved using correlation. The LMedS analysis and Graph Transformation Matching algorithm are used for outliers suppression. Camera projection matrices are computed with the normalized eight point algorithm. Finally, we retrieve 3D position of the retinal tree points by linear triangulation. In order to increase the power of visualization, 3D tree skeletons are represented by surfaces via generalized cylinders whose radius correspond to morphological measurements obtained by RISA. In this paper the complete calibration process including the fundus camera and the optical properties of the eye, the so called camera-eye system is proposed. On one hand, the internal parameters of the fundus camera are obtained by classical algorithms using a reference pattern. On the other hand, we minimize the undesirable efects of the aberrations induced by the eyeball optical system assuming that contact enlarging lens corrects astigmatism, spherical and coma aberrations are reduced changing the aperture size and eye refractive errors are suppressed adjusting camera focus during image acquisition. Evaluation of two self-calibration proposals and results of 3D blood vessel surface reconstruction are presented.

  9. Gun muzzle flash detection using a single photon avalanche diode array in 0.18µm CMOS technology

    NASA Astrophysics Data System (ADS)

    Savuskan, Vitali; Jakobson, Claudio; Merhav, Tomer; Shoham, Avi; Brouk, Igor; Nemirovsky, Yael

    2015-05-01

    In this study, a CMOS Single Photon Avalanche Diode (SPAD) 2D array is used to record and sample muzzle flash events in the visible spectrum, from representative weapons. SPADs detect the emission peaks of alkali salts, potassium or sodium, with spectral emission lines around 769nm and 589nm, respectively. The alkali salts are included in the gunpowder to suppress secondary flashes ignited during the muzzle flash event. The SPADs possess two crucial properties for muzzle flash imaging: (i) very high photon detection sensitivity, (ii) a unique ability to convert the optical signal to a digital signal at the source pixel, thus practically eliminating readout noise. The sole noise sources are the ones prior to the readout circuitry (optical signal distribution, avalanche initiation distribution and nonphotonic generation). This enables high sampling frequencies in the kilohertz range without significant SNR degradation, in contrast to regular CMOS image sensors. This research will demonstrate the SPAD's ability to accurately sample and reconstruct the temporal behavior of the muzzle flash in the visible wavelength, in the presence of sunlight. The reconstructed signal is clearly distinguishable from background clutter, through exploitation of flash temporal characteristics and signal processing, which will be reported. The frame rate of ~16 KHz was chosen as an optimum between SNR degradation and temporal profile recognition accuracy. In contrast to a single SPAD, the 2D array allows for multiple events to be processed simultaneously. Moreover, a significant field of view is covered, enabling comprehensive surveillance and imaging.

  10. Pathogenesis of the dry eye syndrome observed by optical coherence tomography in vitro

    NASA Astrophysics Data System (ADS)

    Kray, Oya; Lenz, Markus; Spöler, Felix; Kray, Stefan; Kurz, Heinrich

    2011-06-01

    Three dimensional optical coherence tomography (OCT) is introduced as a valuable tool to analyze the pathogenesis of corneal diseases. Here, OCT in combination with a novel in vitro model for the dry eye syndrome enables an improved understanding of the underlying damaging process of the ocular surface. En-face OCT projections indicate a deep structural damage of the epithelium and anterior stroma by osmotic forces.

  11. Application of eye movement measuring system OBER 2 to medicine and technology

    NASA Astrophysics Data System (ADS)

    Ober, Jozef; Hajda, Janusz; Loska, Jacek; Jamicki, Michal

    1997-08-01

    The OBER 2 is an infrared light eye movement measuring system and it works with IBM PC compatible computers. As one of the safest systems for measuring of eye movement it uses a very short period of infrared light flashing time (80 microsecond for each measure point). System has an advanced analog-digital controller, which includes background suppression and prediction mechanisms guaranteeing elimination of slow changes and fluctuations of external illumination frequency up to 100 Hz, with effectiveness better than 40 dB. Setting from PC the active measure axis, sampling rate (25 - 4000 Hz) and making start and stop the measure, make it possible to control the outside environment in real-time. By proper controlling of gain it is possible to get high time and position resolution of 0.5 minute of arc even for big amplitude of eye movement (plus or minus 20 degree of visual angle). The whole communication system can also be driven directly by eye movement in real time. The possibility of automatic selection of the most essential elements of eye movement, individual for each person and those that take place for each person in determined situations of life independently from personal features, is a key to practical application. Hence one of conducted research topic is a personal identification based on personal features. Another task is a research project of falling asleep detection, which can be applied to warn the drivers before falling asleep while driving. This measuring system with a proper expert system can also be used to detect a dyslexia and other disabilities of the optic system.

  12. Comparison of objective optical quality measured by double-pass aberrometry in patients with moderate dry eye: Normal saline vs. artificial tears: A pilot study.

    PubMed

    Vandermeer, G; Chamy, Y; Pisella, P-J

    2018-02-01

    Dry eye is defined by a tear film instability resulting in variable but systematic fluctuations in quality of vision. Variability in optical quality can be demonstrated using a double pass aberrometer such as the Optical Quality Analyzing System, Visiometrics (OQAS). The goal of this work is to compare fluctuations in objective quality of vision measured by OQAS between treatment with normal saline eye drops and treatment with carmellose 0.5% and hyaluronic acid 0.1% (Optive Fusion [OF], Allergan) in patients with moderate dry eye syndrome. Optical quality was measured by evaluating the variations in the Optical Scattering Index (OSI) over 20seconds using the OQAS. Inclusion criteria were dry eye syndrome with an ocular surface disease index (OSDI) score >23 treated only with artificial tears. The patients were their own controls: OF in one eye and normal saline in the fellow eye. The choice of the subject eye and control eye was determined in a randomized fashion. OSI variations were measured in each eye before instillation, 5minutes and 2hours after instillation. The primary endpoint was OSI fluctuation over 20seconds of measurement. Secondary endpoints were the number of blinks and patient preference (preferred eye). Preliminary results were obtained on 19 patients. Average OSDI score was 36.8. Visual acuity was 10/10 with no significant difference between the two eyes. Prior to instillation, there was no significant difference between "normal saline" and "OF" eyes in terms of OSI, OSI variability or number of blinks. In the normal saline eye, there were no significant variations in mean OSI, OSI variability, OSI slope, or number of blinks. However, in the "OF" eye, there was a significant variation between initial and 2-hour OSI variability (0.363 versus 0.204, P<0.05), the average slope of OSI (0.04 versus 0.01, P<0.05) and the number of blinks (4.2 versus 2.8, P<0.05). Among the patients, 65% preferred the OF eye, 24% did not have a preference, and 11

  13. [Comparison of objective optical quality measured by double-pass aberrometry in patients with moderate dry eye: Normal saline vs. artificial tears: A pilot study].

    PubMed

    Vandermeer, G; Chamy, Y; Pisella, P-J

    2018-03-01

    Dry eye is defined by a tear film instability resulting in variable but systematic fluctuations in the quality of vision. Variability in optical quality can be demonstrated using a double pass aberrometer such as the OQAS (Optical Quality Analyzing System, Visiometrics). The goal of this work is to compare fluctuations in objective quality of vision measured by OQAS between treatment with normal saline eye drops and treatment with carmellose 0.5% and hyaluronic acid 0.1% (Optive Fusion [OF], Allergan) in patients with moderate dry eye syndrome. Optical quality was measured by evaluating the variations in the Optical Scattering Index (OSI) over 20seconds using the OQAS. Inclusion criteria were dry eye syndrome with an Ocular Surface Disease Index (OSDI) score>23 treated only with artificial tears. The patients were their own controls: OF in one eye and normal saline in the fellow eye. The choice of the subject eye and control eye was determined in a randomized fashion. OSI variations were measured in each eye before instillation, 5minutes and 2hours after instillation. The primary endpoint was OSI fluctuation over 20seconds of measurement. Secondary endpoints were the number of blinks and patient's preference (preferred eye). Preliminary results were obtained on 19 patients. Average OSDI score was 36.8. Visual acuity was 10/10 with no significant difference between the two eyes. Prior to instillation, there was no significant difference between "normal saline" and "OF" eyes in terms of OSI, OSI variability or number of blinks. In the normal saline eye, there was no significant variation in mean OSI, OSI variability, OSI slope, or number of blinks. However, in the "OF" eye, there was a significant variation between initial and 2-hour OSI variability (0.363 versus 0.204; P<0.05), the average slope of OSI (0.04 versus 0.01; P<0.05) and the number of blinks (4.2 versus 2.8; P<0.05). Sixty-five percent of patients preferred the OF eye, 24% did not have a preference, and

  14. Peripapillary Retinoschisis in Glaucomatous Eyes

    PubMed Central

    Lee, Eun Ji; Kim, Tae-Woo; Kim, Mijin; Choi, Yun Jeong

    2014-01-01

    Purpose To investigate the structural and clinical characteristics of peripapillary retinoschisis observed in glaucomatous eyes using spectral-domain optical coherence tomography (SD-OCT). Methods Circumpapillary retinal nerve fiber layer (cpRNFL) and macular cross-hair SD-OCT scans and infrared fundus images of the glaucoma patients from the Investigating Glaucoma Progression Study (IGPS) and healthy volunteers were reviewed. Optic disc images obtained using enhanced depth imaging (EDI) SD-OCT were also evaluated. The structural characteristics and clinical course of the retinoschisis associated with glaucoma were investigated. Results Twenty-five retinoschisis areas were found in 22 of the 372 patients (5.9%) included in the IGPS, and in 1 area in 1 of 187 healthy control subjects (0.5%). In the 22 glaucomatous eyes with retinoschisis, the schisis was attached to the optic disc and overlapped with the retinal nerve fiber layer (RNFL) defect. The RNFL was the layer most commonly affected by the retinoschisis, either alone or together with other deeper layers. Acquired optic disc pit was identified in 8 eyes on disc photography and/or B-scan images obtained by EDI SD-OCT. Spontaneous resolution of this condition was observed in nine eyes. No retinal detachment or macular involvement of the retinoschisis was observed in any of the eyes. Multivariate analysis showed a significant influence of a higher intraocular pressure at SD-OCT scanning on the presence of retinoschisis (Odds ratio  = 1.418, P = 0.001). Conclusions The present study investigated 22 cases of peripapillary retinoschisis in glaucomatous eyes. The retinoschisis was attached to the optic nerve and topographically correlated with RNFL defect. It often resolved spontaneously without causing severe visual disturbance. Care should be taken not to overestimate the RNFL thickness in eyes with retinoschisis, and also not to misinterpret the resolution of retinoschisis as a rapid glaucomatous RNFL

  15. Multifocal visual evoked potential in optic neuritis, ischemic optic neuropathy and compressive optic neuropathy

    PubMed Central

    Jayaraman, Manju; Gandhi, Rashmin Anilkumar; Ravi, Priya; Sen, Parveen

    2014-01-01

    Purpose: To investigate the effect of optic neuritis (ON), ischemic optic neuropathy (ION) and compressive optic neuropathy (CON) on multifocal visual evoked potential (mfVEP) amplitudes and latencies, and to compare the parameters among three optic nerve disorders. Materials and Methods: mfVEP was recorded for 71 eyes of controls and 48 eyes of optic nerve disorders with subgroups of optic neuritis (ON, n = 21 eyes), ischemic optic neuropathy (ION, n = 14 eyes), and compressive optic neuropathy (CON, n = 13 eyes). The size of defect in mfVEP amplitude probability plots and relative latency plots were analyzed. The pattern of the defect in amplitude probability plot was classified according to the visual field profile of optic neuritis treatment trail (ONTT). Results: Median of mfVEP amplitude (log SNR) averaged across 60 sectors were reduced in ON (0.17 (0.13-0.33)), ION (0.14 (0.12-0.21)) and CON (0.21 (0.14-0.30)) when compared to controls. The median mfVEP relative latencies compared to controls were significantly prolonged in ON and CON group of 10.53 (2.62-15.50) ms and 5.73 (2.67-14.14) ms respectively compared to ION group (2.06 (-4.09-13.02)). The common mfVEP amplitude defects observed in probability plots were diffuse pattern in ON, inferior altitudinal defect in ION and temporal hemianopia in CON eyes. Conclusions: Optic nerve disorders cause reduction in mfVEP amplitudes. The extent of delayed latency noted in ischemic optic neuropathy was significantly lesser compared to subjects with optic neuritis and compressive optic neuropathy. mfVEP amplitudes can be used to objectively assess the topography of the visual field defect. PMID:24088641

  16. The Optic Nerve Head in Primary Open-Angle Glaucoma Eyes With High Myopia: Characteristics and Association With Visual Field Defects.

    PubMed

    Chen, Li-Wei; Lan, Yu-Wen; Hsieh, Jui-Wen

    2016-06-01

    To evaluate the morphologic characteristics of optic neuropathy and its association with visual field (VF) defects in primary open-angle glaucoma (POAG) eyes with high myopia. In this cross-sectional study, we reviewed data from 375 Taiwanese patients (375 eyes) of POAG, ages 20 to 60 years. Optic disc photographs were used for planimetric measurements of morphologic variables. The myopic refraction was divided into high myopia (<-6.0 D) and nonhigh myopia (moderate myopia to hyperopia). The optic disc area was classified as moderate (1.59 to 2.85 mm), large, and small. Differences in characteristics between groups, correlations with the disc area, and factors associated with VF defects were determined. Of the 142 highly myopic eyes, 33 (23%) had a large disc, 26 (18%) had a small disc, and 55 (39%) had a tilted disc. Large discs had a higher cup-to-disc (C/D) area ratio and a higher tilt ratio; small discs had a smaller rim area and a lower tilt ratio (all P<0.05). Characteristics associated with high myopia included a smaller rim area, a higher C/D area ratio, and a lower tilt ratio (all P<0.001). In logistic regression, the refraction, the C/D area ratio, the rim area, and the tilt ratio (all P<0.05) were associated with VF defects. In Taiwanese individuals with POAG, our study found that tilted, large, or small discs were prevalent in highly myopic eyes. Of these characteristics, only the disc tilt and high myopia by itself were associated with the severity of glaucomatous optic neuropathy.

  17. Saccadic Suppression of Flash Detection: the Uncertainty Theory VS. Alternative Theories.

    NASA Astrophysics Data System (ADS)

    Greenhouse, Daniel Stephen

    Helmholtz('1) and others have proposed that when a saccadic eye movement occurs, stability of the visual world is maintained by a process that utilizes a corollary to the efferent motor signal for the eye movement, allowing the visual frame of reference to translate equal in magnitude, but opposite in sign, to the movement itself. This process is now known to be synchronous neither with the saccadic trajectory('2,3) nor in all parts of the visual field.('4) In addition, this process has been shown to have variability('2) whereby the perceived visual direction of a flash presented to a fixed retinal locus during a saccade may change from trial to trial. Hence, uncertainty with respect to visual location of a stimulus may exist during and just before a saccade. It has been established for normal vision that uncertainty produces a decline in detectability of a weak stimulus.('5,6,7) The research reported in this dissertation was performed to test the notion, first suggested by L. Matin,('8) that uncertainty is responsible for saccadic suppression, the decline in detectability that has been reported('9,10,11) for a brief flash presented during a saccade. After having established the existence of suppression under the conditions we employed (1(DEGREES) foveal flash occurring 2 1/2(DEGREES) into a 10(DEGREES) voluntary saccade, presented against an illuminated background) we conducted an initial test of the uncertainty theory. We employed a pedestal (flash at the spatial, temporal, and chromatic locus of the stimulus, occurring on all trials, and sufficiently intense as to be visible during saccades) in an attempt to reduce uncertainty. Suppression was nearly eliminated for all subjects. We interpreted this result in terms of the uncertainty theory, but were unable to reject alternative theories of suppression, which include forms of neural inhibition,('10,11) increaed noise level in the retina during saccades,('12) and metacontrast masking.('13). The next experiment

  18. Multi- and unisensory visual flash illusions.

    PubMed

    Courtney, Jon R; Motes, Michael A; Hubbard, Timothy L

    2007-01-01

    The role of stimulus structure in multisensory and unisensory interactions was examined. When a flash (17 ms) was accompanied by multiple tones (each 7 ms, SOA < or =100 ms) multiple flashes were reported, and this effect has been suggested to reflect the role of stimulus continuity in multisensory interactions. In experiments 1 and 2 we examined if stimulus continuity would affect concurrently presented stimuli. When a relatively longer flash (317 ms) was accompanied by multiple tones (each 7 ms), observers reported perceiving multiple flashes. In experiment 3 we tested whether a flash presented near fixation would induce an illusory flash further in the periphery. One flash (17 ms) presented 5 degrees below fixation was reported as multiple flashes if presented with two flashes (each 17 ms, SOA =100 ms) 2 degrees above fixation. The extent to which these data support a phenomenological continuity principle and whether this principle applies to unisensory perception is discussed.

  19. Two-flash thresholds as a function of flash luminance and area.

    DOT National Transportation Integrated Search

    1968-09-01

    The recent use of strobe lights in aviation suggests the possibility of using temporal patterns of short duration flashes as information-carrying signals. Under night flight conditions, two-flash thresholds were obtained using a two-interval, tempora...

  20. Subretinal delivery and electroporation in pigmented and nonpigmented adult mouse eyes

    PubMed Central

    Nickerson, John M.; Goodman, Penny; Chrenek, Micah A.; Johnson, Christiana J.; Berglin, Lennart; Redmond, T. Michael.; Boatright, Jeffrey H.

    2013-01-01

    Subretinal injection offers one of the best ways to deliver many classes of drugs, reagents, cells and treatments to the photoreceptor, Müller, and retinal pigment epithelium (RPE) cells of the retina. Agents delivered to this space are placed within microns of the intended target cell, accumulating to high concentrations because there is no dilution due to transport processes or diffusion. Dilution in the interphotoreceptor space (IPS) is minimal because the IPS volume is only 10-20 microliters in the human eye and less than 1 microliter in the mouse eye. For gene delivery purposes, we wished to transfect the cells adjacent to the IPS in adult mouse eyes. Others transfect these cells in neonatal rats to study the development of the retina. In both neonates and adults, electroporation is found to be effective Here we describe the optimization of electroporation conditions for RPE cells in the adult mouse eye with naked plasmids. However, both techniques, subretinal injection and electroporation, present some technical challenges that require skill on the part of the surgeon to prevent untoward damage to the eye. Here we describe methods that we have used for the past ten years (1). PMID:22688698

  1. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes

    PubMed Central

    Mao, Xinjie; Banta, James T.; Ke, Bilian; Jiang, Hong; He, Jichang; Liu, Che; Wang, Jianhua

    2016-01-01

    Purpose To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor. Methods Twenty-eight adult subjects (32 pseudophakic eyes) having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR) and intraclass correlation coefficient (ICC) were calculated. Results Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951. Conclusions The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye. PMID:27010674

  2. The fields of a naked singularity and a black hole in mutual equilibrium

    NASA Astrophysics Data System (ADS)

    Paolino, Armando; Pizzi, Marco

    2008-01-01

    Recently Alekseev and Belinski have presented a new exact solution of the Einstein-Maxwell equation which describes two Reissner-Nordstrom (RN) sources in reciprocal equilibrium (no struts nor strings) one source is a naked singularity, the other is a black hole. In this paper we use the Alekseev-Belinki solution in the special case in which the charge of the black hole is zero-therefore we have a naked singularity near a neutral black hole. We give the plots of the electric force lines in both the cases in which the naked singularity has a mass comparable with the black hole and in which it is much smaller. The analysis of this latter case confirm the goodness of the Hanni-Ruffini approximation.

  3. Flash characteristics of plasma induced by hypervelocity impact

    NASA Astrophysics Data System (ADS)

    Zhang, Kai; Long, Renrong; Zhang, Qingming; Xue, Yijiang; Ju, Yuanyuan

    2016-08-01

    Using a two-stage light gas gun, a series of hypervelocity impact experiments was conducted in which 6.4-mm-diameter spherical 2024-aluminum projectiles impact 23-mm-thick targets made of the same material at velocities of 5.0, 5.6, and 6.3 km/s. Both an optical pyrometer composed of six photomultiplier tubes and a spectrograph were used to measure the flash of the plasma during hypervelocity impact. Experimental results show that, at a projectile velocity of 6.3 km/s, the strong flash lasted about 10 μs and reached a temperature of 4300 K. Based on the known emission lines of AL I, spectral methods can provide the plasma electron temperature. An electron-temperature comparison between experiment and theoretical calculation indicates that single ionization and secondary ionization are the two main ionizing modes at velocities 5.0-6.3 km/s.

  4. Orbiting naked singularities in large-ω Brans-Dicke gravity

    NASA Astrophysics Data System (ADS)

    Chauvineau, Bertrand

    2017-11-01

    Brans-Dicke gravity admits spherical solutions describing naked singularities rather than black holes. Depending on some parameters entering such a solution, stable circular orbits exist for all radii. One shows that, despite the fact a naked singularity is an infinite redshift location, the far observed orbital motion frequency is unbounded for an adiabatically decreasing radius. We then argue that this feature remains true in a wide set of scalar(s)-tensor theories if gravity. This is a salient difference with general relativity, and the repercussion on the gravitational radiation by EMRI systems is stressed. Since this behaviour survives the ω \\longrightarrow ∞ limit, the possibility of such solutions is of utmost interest in the new gravitational wave astronomy context, despite the current constraints on scalar-tensor gravity.

  5. A Method for Retrieving Ground Flash Fraction from Satellite Lightning Imager Data

    NASA Technical Reports Server (NTRS)

    Koshak, William J.

    2009-01-01

    A general theory for retrieving the fraction of ground flashes in N lightning observed by a satellite-based lightning imager is provided. An "exponential model" is applied as a physically reasonable constraint to describe the measured optical parameter distributions, and population statistics (i.e., mean, variance) are invoked to add additional constraints to the retrieval process. The retrieval itself is expressed in terms of a Bayesian inference, and the Maximum A Posteriori (MAP) solution is obtained. The approach is tested by performing simulated retrievals, and retrieval error statistics are provided. The ability to retrieve ground flash fraction has important benefits to the atmospheric chemistry community. For example, using the method to partition the existing satellite global lightning climatology into separate ground and cloud flash climatologies will improve estimates of lightning nitrogen oxides (NOx) production; this in turn will improve both regional air quality and global chemistry/climate model predictions.

  6. Communication using eye roll reflective signalling

    USGS Publications Warehouse

    Flamarique, I.N.; Mueller, G.A.; Cheng, C.L.; Figiel, C.R.

    2007-01-01

    Body reflections in the ultraviolet (UV) are a common occurrence in nature. Despite the abundance of such signals and the presence of UV cones in the retinas of many vertebrates, the function of UV cones in the majority of taxa remains unclear. Here, we report on an unusual communication system in the razorback sucker, Xyrauchen texanus, that involves flash signals produced by quick eye rolls. Behavioural experiments and field observations indicate that this form of communication is used to signal territorial presence between males. The flash signal shows highest contrast in the UV region of fhe visual spectrum (??max???380 nm), corresponding to the maximum wavelength of absorption of the UV cone mechanism in suckers. Furthermore, these cones are restricted to the dorsal retina of the animal and the upwelling light background is such that their relative sensitivity would be enhanced by chromatic adaptation of the other cone mechanisms. Thus, the UV cones in the sucker have optimal characteristics (both in terms of absorbance and retinal topography) to constitute the main detectors of the flash signal. Our findings provide the first ecological evidence for restricted distribution of UV cones in the retina of a vertebrate. ?? 2007 The Royal Society.

  7. Involuntary eye motion correction in retinal optical coherence tomography: Hardware or software solution?

    PubMed

    Baghaie, Ahmadreza; Yu, Zeyun; D'Souza, Roshan M

    2017-04-01

    In this paper, we review state-of-the-art techniques to correct eye motion artifacts in Optical Coherence Tomography (OCT) imaging. The methods for eye motion artifact reduction can be categorized into two major classes: (1) hardware-based techniques and (2) software-based techniques. In the first class, additional hardware is mounted onto the OCT scanner to gather information about the eye motion patterns during OCT data acquisition. This information is later processed and applied to the OCT data for creating an anatomically correct representation of the retina, either in an offline or online manner. In software based techniques, the motion patterns are approximated either by comparing the acquired data to a reference image, or by considering some prior assumptions about the nature of the eye motion. Careful investigations done on the most common methods in the field provides invaluable insight regarding future directions of the research in this area. The challenge in hardware-based techniques lies in the implementation aspects of particular devices. However, the results of these techniques are superior to those obtained from software-based techniques because they are capable of capturing secondary data related to eye motion during OCT acquisition. Software-based techniques on the other hand, achieve moderate success and their performance is highly dependent on the quality of the OCT data in terms of the amount of motion artifacts contained in them. However, they are still relevant to the field since they are the sole class of techniques with the ability to be applied to legacy data acquired using systems that do not have extra hardware to track eye motion. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Polarizing optics in a spider eye.

    PubMed

    Mueller, Kaspar P; Labhart, Thomas

    2010-05-01

    Many arthropods including insects and spiders exploit skylight polarization for navigation. One of the four eye pairs of the spider Drassodes cupreus is dedicated to detect skylight polarization. These eyes are equipped with a tapetum that strongly plane-polarizes reflected light. This effectively enhances the polarization-sensitivity of the photoreceptors, improving orientation performance. With a multidisciplinary approach, we demonstrate that D. cupreus exploits reflective elements also present in non-polarizing tapetal eyes of other species such as Agelena labyrinthica. By approximately orthogonal arrangement of two multilayer reflectors consisting of reflecting guanine platelets, the tapetum uses the mechanism of polarization by reflection for polarizing reflected light.

  9. On-eye optical quality of daily disposable contact lenses for different wearing times.

    PubMed

    Montés-Micó, Robert; Belda-Salmerón, Lurdes; Ferrer-Blasco, Teresa; Albarrán-Diego, César; García-Lázaro, Santiago

    2013-09-01

    To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analysed by fitting Zernike polynomials up to the 5th-order for 3 and 5-mm pupils. The optical quality under each condition and at each point in time was described by means of the Root-Mean-Square (RMS) value of wavefront aberration, Modulation Transfer Function (MTF), Point Spread Function and cut-off spatial frequency. A RMS increase was observed after contact lens fitting as well as over time, both for a 3-mm and a 5-mm pupil. Each type of lens induced a different amount of wavefront aberrations, which vary over time also in a different manner. Dailies Total1 showed the lowest RMS values both at baseline and at the end of the day. In addition, Dailies Total1 provided the best MTF out of all the contact lenses that were assessed. These observations were reflected in higher cut-off spatial frequencies and visual resolution both at baseline and after 12 h of wearing time. Aberrometry makes it possible to analyse accurately and in vivo the optical quality of contact lenses and to assess how lenses having different characteristics - such as material or water content - behave for different wearing times. These variations across contact lenses may result in differences in visual performance. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  10. Cosmic ray effects on the eyes of rats flown on Cosmos no. 782, Experiment K-007

    NASA Technical Reports Server (NTRS)

    Philpott, D. E.; Corbett, R.; Turnbill, C.; Harrison, G.; Leaffer, D.; Black, S.; Sapp, W.; Klein, G.; Savik, L. F.

    1978-01-01

    A study was undertaken to determine if, and to what extent, pathological damage results from high-energy particles (HZE) transversing the eye. Light flashes experienced by space travellers indicate that HZE do indeed pass through and activate the retina, but whether actual biological damage occurs has not been investigated thoroughly. Thus, autopsies were performed on the eyes of rats which has been flown in Cosmos 782 satellite for 19.5 days. Comparisons with a control sample subjected to 1000 rads of Ar and Ne radiation show that pathological damage, when it occurs, affects the nucleus of the retina; simple light flashes are not thought to indicate a pathology, and result from activation of (but not damage to) the retina's outer segments.

  11. Fast uncooled module 32×32 array of polycrystalline PbSe used for muzzle flash detection

    NASA Astrophysics Data System (ADS)

    Kastek, Mariusz; Dulski, Rafał; Trzaskawka, Piotr; Bieszczad, Grzegorz

    2011-06-01

    The paper presents some aspects of muzzle flash detection using low resolution polycrystalline PbSe uncooled 32×32 detectors array. This system for muzzle flash detection works in MWIR (3 - 5 microns) region and it is based on VPD (Vapor Phase Deposition) technology. The low density uncooled 32×32 array is suitable for being used in low cost IR imagers sensitive in the MWIR band with frame rates exceeding 1.000 Hz. The FPA detector, read-out electronics and processing electronics (allowing the implementation of some algorithms for muzzle flash detection) has been presented. The system has been tested at field test ground. Results of detection range measurement with two types of optical systems (wide and narrow field of view) have been shown. The initial results of testing of some algorithms for muzzle flash detection have been also presented.

  12. The Pupil Light Reflex in Leber's Hereditary Optic Neuropathy: Evidence for Preservation of Melanopsin-Expressing Retinal Ganglion Cells

    PubMed Central

    Moura, Ana Laura A.; Nagy, Balázs V.; La Morgia, Chiara; Barboni, Piero; Oliveira, André Gustavo Fernandes; Salomão, Solange R.; Berezovsky, Adriana; de Moraes-Filho, Milton Nunes; Chicani, Carlos Filipe; Belfort, Rubens; Carelli, Valerio; Sadun, Alfredo A.; Hood, Donald C.; Ventura, Dora Fix

    2013-01-01

    Purpose. To investigate the pupillary light reflex (PLR) of patients with severe loss of vision due to Leber's Hereditary Optic Neuropathy (LHON) in the context of a proposed preservation of melanopsin-expressing retinal ganglion cells (mRGCs). Methods. Ten LHON patients (7 males; 51.6 ± 14.1 years), with visual acuities ranging from 20/400 to hand motion perception and severe visual field losses, were tested and compared with 16 healthy subjects (7 males; 42.15 ± 15.4 years) tested as controls. PLR was measured with an eye tracker and the stimuli were controlled with a Ganzfeld system. Pupil responses were measured monocularly, to 1 second of blue (470 nm) and red (640 nm) flashes with 1, 10, 100, and 250 cd/m2 luminances. The normalized amplitude of peak of the transient PLR and the amplitude of the sustained PLR at 6 seconds after the flash offset were measured. In addition, optical coherence topography (OCT) scans of the peripapillary retinal nerve fiber layer were obtained. Results. The patient's peak PLR responses were on average 15% smaller than controls (P < 0.05), but 5 out of 10 patients had amplitudes within the range of controls. The patients' sustained PLRs were comparable with controls at lower flash intensities, but on average, 27% smaller to the 250 cd/m2 blue light, although there was considerable overlap with the PLR amplitudes of control. All patients had severe visual field losses and the retinal nerve fiber layer thickness was reduced to a minimum around the optic disc in 8 of the 10 patients. Conclusions. The PLR is maintained overall in LHON patients despite the severity of optic atrophy. These results are consistent with previous evidence of selective preservation of mRGCs. PMID:23737476

  13. ``Staying in Focus'' - An Online Optics Tutorial on the Eye

    NASA Astrophysics Data System (ADS)

    Hoeling, Barbara M.

    2011-02-01

    The human eye and its vision problems are often used as an entry subject and attention grabber in the teaching of geometrical optics. While this is a real-life application students can relate to, it is difficult to visualize how the eye forms images by studying the still pictures and drawings in a textbook. How to draw a principal ray diagram or how to calculate the image distance from a given object distance and focal length might be clear to most students after studying the book, but even then they often lack an understanding of the "big picture." Where is the image of a very far away object located? How come we can see both far away and close-by objects focused (although not simultaneously)? Computer animations,2 popular with our computer-game savvy students, provide considerably more information than the still images, especially if they allow the user to manipulate parameters and to observe the outcome of a "virtual" experiment. However, as stand-alone learning tools, they often don't provide the students with the necessary physics background or instruction on how to use them.

  14. Naked Black Hole Firewalls.

    PubMed

    Chen, Pisin; Ong, Yen Chin; Page, Don N; Sasaki, Misao; Yeom, Dong-Han

    2016-04-22

    In the firewall proposal, it is assumed that the firewall lies near the event horizon and should not be observable except by infalling observers, who are presumably terminated at the firewall. However, if the firewall is located near where the horizon would have been, based on the spacetime evolution up to that time, later quantum fluctuations of the Hawking emission rate can cause the "teleological" event horizon to have migrated to the inside of the firewall location, rendering the firewall naked. In principle, the firewall can be arbitrarily far outside the horizon. This casts doubt about the notion that firewalls are the "most conservative" solution to the information loss paradox.

  15. Naked Black Hole Firewalls

    NASA Astrophysics Data System (ADS)

    Chen, Pisin; Ong, Yen Chin; Page, Don N.; Sasaki, Misao; Yeom, Dong-han

    2016-04-01

    In the firewall proposal, it is assumed that the firewall lies near the event horizon and should not be observable except by infalling observers, who are presumably terminated at the firewall. However, if the firewall is located near where the horizon would have been, based on the spacetime evolution up to that time, later quantum fluctuations of the Hawking emission rate can cause the "teleological" event horizon to have migrated to the inside of the firewall location, rendering the firewall naked. In principle, the firewall can be arbitrarily far outside the horizon. This casts doubt about the notion that firewalls are the "most conservative" solution to the information loss paradox.

  16. A precocious adult visual center in the larva defines the unique optic lobe of the split-eyed whirligig beetle Dineutus sublineatus

    PubMed Central

    2013-01-01

    Introduction Whirligig beetles (Coleoptera: Gyrinidae) are aquatic insects living on the water surface. They are equipped with four compound eyes, an upper pair viewing above the water surface and a lower submerged pair viewing beneath the water surface, but little is known about how their visual brain centers (optic lobes) are organized to serve such unusual eyes. We show here, for the first time, the peculiar optic lobe organization of the larval and adult whirligig beetle Dineutus sublineatus. Results The divided compound eyes of adult whirligig beetles supply optic lobes that are split into two halves, an upper half and lower half, comprising an upper and lower lamina, an upper and lower medulla and a bilobed partially split lobula. However, the lobula plate, a neuropil that in flies is known to be involved in mediating stabilized flight, exists only in conjunction with the lower lobe of the lobula. We show that, as in another group of predatory beetle larvae, in the whirligig beetle the aquatic larva precociously develops a lobula plate equipped with wide-field neurons. It is supplied by three larval laminas serving the three dorsal larval stemmata, which are adjacent to the developing upper compound eye. Conclusions In adult whirligig beetles, dual optic neuropils serve the upper aerial eyes and the lower subaquatic eyes. The exception is the lobula plate. A lobula plate develops precociously in the larva where it is supplied by inputs from three larval stemmata that have a frontal-upper field of view, in which contrasting objects such as prey items trigger a body lunge and mandibular grasp. This precocious lobula plate is lost during pupal metamorphosis, whereas another lobula plate develops normally during metamorphosis and in the adult is associated with the lower eye. The different roles of the upper and lower lobula plates in supporting, respectively, larval predation and adult optokinetic balance are discussed. Precocious development of the upper lobula

  17. High-speed adaptive optics for imaging of the living human eye

    PubMed Central

    Yu, Yongxin; Zhang, Tianjiao; Meadway, Alexander; Wang, Xiaolin; Zhang, Yuhua

    2015-01-01

    The discovery of high frequency temporal fluctuation of human ocular wave aberration dictates the necessity of high speed adaptive optics (AO) correction for high resolution retinal imaging. We present a high speed AO system for an experimental adaptive optics scanning laser ophthalmoscope (AOSLO). We developed a custom high speed Shack-Hartmann wavefront sensor and maximized the wavefront detection speed based upon a trade-off among the wavefront spatial sampling density, the dynamic range, and the measurement sensitivity. We examined the temporal dynamic property of the ocular wavefront under the AOSLO imaging condition and improved the dual-thread AO control strategy. The high speed AO can be operated with a closed-loop frequency up to 110 Hz. Experiment results demonstrated that the high speed AO system can provide improved compensation for the wave aberration up to 30 Hz in the living human eye. PMID:26368408

  18. Optical transmission and laser ablation of pathologically changed eye lens capsule

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gamidov, A A; Bolshunov, A V; Yuzhakov, A V

    Optical transmission and ablation mechanisms in the secondary cataract films under the impact of 1.06-mm laser radiation are studied. The comparison of incident and transmitted (paraxial) radiation power at different values of the power density is carried out for two types of the eye lens capsule tissue (hard and soft) possessing different optical and mechanical properties. It is found that the effective attenuation coefficient for soft films is almost five times as large as that for the hard ones. The obtained measurement data on the transparency variation in the process of laser action allow the temperature evaluation and the determinationmore » of dominant mechanism of laser ablation, as well as the development of recommendations, providing the prevention or reduction of possible side effects. The obtained results can be used to optimise the regimes of laser impact in the process of the opacified lens capsule removal.« less

  19. Method and apparatus for implementing material thermal property measurement by flash thermal imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Jiangang

    A method and apparatus are provided for implementing measurement of material thermal properties including measurement of thermal effusivity of a coating and/or film or a bulk material of uniform property. The test apparatus includes an infrared camera, a data acquisition and processing computer coupled to the infrared camera for acquiring and processing thermal image data, a flash lamp providing an input of heat onto the surface of a two-layer sample with an enhanced optical filter covering the flash lamp attenuating an entire infrared wavelength range with a series of thermal images is taken of the surface of the two-layer sample.

  20. Improved thermal stability of oxide-supported naked gold nanoparticles by ligand-assisted pinning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreno, C; Divins, N. J.; Gazquez, Jaume

    We report a method to improve the thermal stability, up to 900 C, of bare-metal (naked) gold nanoparticles supported on top of SiO{sub 2} and SrTiO{sub 3} substrates via ligand-assisted pinning. This approach leads to monodisperse naked gold nanoparticles without significant sintering after thermal annealing in air at 900 C. The ligand-assisted pinning mechanism is described.

  1. Effects of background stimulation upon eye-movement information.

    PubMed

    Nakamura, S

    1996-04-01

    To investigate the effects of background stimulation upon eye-movement information (EMI), the perceived deceleration of the target motion during pursuit eye movement (Aubert-Fleishl paradox) was analyzed. In the experiment, a striped pattern was used as a background stimulus with various brightness contrasts and spatial frequencies for serially manipulating the attributions of the background stimulus. Analysis showed that the retinal-image motion of the background stimulus (optic flow) affected eye-movement information and that the effects of optic flow became stronger when high contrast and low spatial frequency stripes were presented as the background stimulus. In conclusion, optic flow is one source of eye-movement information in determining real object motion, and the effectiveness of optic flow depends on the attributes of the background stimulus.

  2. Analysis of Retinal Thinning Using Spectral-domain Optical Coherence Tomography Imaging of Sickle Cell Retinopathy Eyes Compared to Age- and Race-Matched Control Eyes.

    PubMed

    Lim, Jennifer I; Cao, Dingcai

    2018-03-17

    To determine whether the retina is thinner in sickle cell patients than in race- and age-matched controls, and, if it is thinner, whether there is any association with systemic diseases. Sickle cell and control (age- and race-matched) patients were prospectively enrolled from a university retina clinic into this observational study. Participants underwent visual acuity testing, slit-lamp biomicroscopy, dilated ophthalmoscopy, and spectral-domain optical coherence tomography imaging. Sickle cell retinal lesions, degree of vascular tortuosity, caliber of arteriovenous anastomosis, and stage of retinopathy were noted. Early Treatment Diabetic Retinopathy Study (ETDRS) subfield measurements were compared between sickle cell and control subjects and also among sickle cell hemoglobin subtypes. Associations between ETDRS subfield measurements and hemoglobin subtype, retinopathy stage, and systemic diseases were assessed. A total of 513 sickle cell eyes (260 patients) and 75 control eyes (39 patients) had median visual acuities of 20/20. ETDRS central (P = .002), inner (nasal P = .009, superior P = .021, temporal P < .001, inferior P = .017), and temporal outer (P = .012) subfield measurements were thinner in sickle cell eyes compared to control eyes. Hemoglobin SS eyes had significantly thinner inner ETDRS subfield measurements compared to SC and SThal eyes. Retinal thinning in all subfields was associated with age (P = .017) for sickle cell and control eyes. No association was found between retinal thinning and hydroxyurea use or arteriovenous anastomosis caliber. The macula is thinner in sickle cell eyes compared to control eyes; retinal thickness decreases with increasing age and sickle cell retinopathy stage and is most severe in hemoglobin SS subtypes. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Unilateral Anterior Ischemic Optic Neuropathy: Chromatic Pupillometry in Affected, Fellow Non-Affected and Healthy Control Eyes

    PubMed Central

    Herbst, Kristina; Sander, Birgit; Lund-Andersen, Henrik; Wegener, Marianne; Hannibal, Jens; Milea, Dan

    2013-01-01

    The intrinsically photosensitive retinal ganglion cells (ipRGCs) express the photopigment melanopsin, which is sensitive to blue light. Previous chromatic pupillometry studies have shown that the post-illumination response is considered an indicator of the melanopsin activation. The aim of this study was to investigate the ipRGC mediated pupil response in patients with a unilateral non-arteritic anterior ischemic optic neuropathy (NAION). Consensual pupil responses during and after exposure to continuous 20 s blue (470 nm) or red (660 nm) light of high intensity (300 cd/m2) were recorded in each eye for 10 patients. Comparisons were performed both intra-individually (affected versus non-affected eyes) and inter-individually (compared with healthy controls). The pupil response was calculated both during the illumination and during the post-illumination phase. The pupil responses to blue and red colors were significantly reduced in the NAION-affected eyes, compared with the fellow non-affected eyes. When comparing the affected eyes with the healthy control eyes, the post-illumination responses were not significantly different. In addition, the post-illumination pupil responses after blue light exposure were increased in the fellow non-affected patients’ eyes, compared with the healthy controls. However, significance was only reached for the late post-illumination response. In conclusion, chromatic pupillometry disclosed reduced post-illumination pupil responses in the NAION-affected eyes, compared with the non-affected fellow eyes, suggesting dysfunction of the ipRGCs. Compared with the responses of the healthy controls, the blue light post-illumination pupil responses were similar in the affected eyes and increased in the fellow non-affected eyes. This suggests a possible adaptive phenomenon, involving the ipRGCs of both eyes after unilateral NAION. PMID:23717301

  4. Bright half-cycle optical radiation from relativistic wavebreaking

    NASA Astrophysics Data System (ADS)

    Miao, Bo; Goers, Andy; Hine, George; Feder, Linus; Salehi, Fatholah; Wahlstrand, Jared; Milchberg, Howard

    2015-11-01

    Wavebreaking injection of electrons into relativistic plasma wakes generated in near-critical density hydrogen plasmas by sub-terawatt laser pulses is observed to generate an extremely energetic and ultra-broadband radiation flash. The flash is coherent, with a bandwidth of Δλ / λ ~ 0 . 7 consistent with half-cycle optical emission of duration ~ 1 fs from violent unidirectional acceleration of electrons to light speed from rest over a distance much less than the radiated wavelength. We studied the temporal duration and coherence of the flash by interfering it in the frequency domain with a well-characterized Xe supercontinuum pulse. Fringes across the full flash spectrum were observed with high visibility, and the extracted flash spectral phase supports it being a nearly transform-limited pulse. To our knowledge, this is the first evidence of bright half-cycle optical emission. This research is supported by the Defense Threat Reduction Agency, the US Department of Energy, and the Air Force Office of Scientific Research.

  5. The effect of actinoquinol with hyaluronic acid in eye drops on the optical properties and oxidative damage of the rabbit cornea irradiated with UVB rays.

    PubMed

    Čejka, Čestmír; Luyckx, Jacques; Ardan, Taras; Pláteník, Jan; Širc, Jakub; Michálek, Jiří; Čejková, Jitka

    2010-01-01

    Irradiation of the cornea with UVB rays leads to its oxidative damage, swelling and increased light absorption. We investigated changes in the corneal optics (evaluated by changes of corneal hydration and light absorption) and microscopical disturbances of corneas irradiated with UVB rays as influenced by eye drops containing actinoquinol with hyaluronic acid. Rabbit corneas were irradiated with a daily dose of 0.5 or 1.01 J cm(-2) of UVB rays (312 nm) for 4 days. During irradiation, the eye drops were applied on the right eye and buffered saline (or hyaluronic acid) on the left eye. On day 5 the rabbits were sacrificed and the corneas examined spectrophotometrically for light absorption. The corneal thickness (hydration) was measured using a pachymeter. Corneas of some other rabbits were examined immunohistochemically. After buffered saline treatment UVB rays evoked changes in the corneal optics and induced oxidative damage of the corneas. After actinoquinol-hyaluronic acid application, these changes were diminished. Hyaluronic acid alone was less effective. In conclusion, actinoquinol-hyaluronic acid eye drops decreased changes in corneal optics and suppressed oxidative damage in the UVB-irradiated cornea. However, the effective corneal protection by these eye drops was limited to the lower UVB dose. © 2010 The Authors. Journal Compilation. The American Society of Photobiology.

  6. Apollo-Soyuz light-flash observations. [ionizing radiation effects measurement

    NASA Technical Reports Server (NTRS)

    Budinger, T. F.; Tobias, C. A.; Huesman, R. H.; Upham, F. T.; Wieskamp, T. F.; Hoffman, R. A.

    1977-01-01

    While dark adapted, two Apollo-Soyuz astronauts saw eighty-two light flash events during a complete 51 deg orbit which passed near the north magnetic pole and through the South Atlantic Anomaly. The frequency of events at the polar parts of the orbit is 25 times that noted in equatorial latitudes and no increased frequency was noted in the South Atlantic Anomaly at the 225-km altitude. The expected flux of heavy particles at the northern and southern points is 1-2/min per eye, and the efficiency for seeing high Z-high energy (HZE) particles which were below the Cerenkov threshold is 50%.

  7. Flash-Type Discrimination

    NASA Technical Reports Server (NTRS)

    Koshak, William J.

    2010-01-01

    This viewgraph presentation describes the significant progress made in the flash-type discrimination algorithm development. The contents include: 1) Highlights of Progress for GLM-R3 Flash-Type discrimination Algorithm Development; 2) Maximum Group Area (MGA) Data; 3) Retrieval Errors from Simulations; and 4) Preliminary Global-scale Retrieval.

  8. Whole eye axial biometry during accommodation using ultra-long scan depth optical coherence tomography

    PubMed Central

    Zhong, Jianguang; Tao, Aizhu; Xu, Zhe; Jiang, Hong; Shao, Yilei; Zhang, Huicheng; Liu, Che; Wang, Jianhua

    2014-01-01

    PURPOSE To investigate changes of whole eye axial biometry during accommodation using ultra-long scan depth optical coherence tomography (UL-OCT). DESIGN Prospective, observational case series. METHODS Twenty-one adult subjects were enrolled. Using UL-OCT, the left eye of each subject was imaged with relaxed (0 D) and accommodative stimuli (+6 D). Full eye biometry included central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness, vitreous length and axial length (AL). RESULTS During accommodation (+6 D), the axial biometry of the whole eye changed significantly. Compared to the rest state, ACD at the accommodative state decreased significantly from 3.128 ± 0.305 mm to 2.961 ± 0.298 mm (paired t-test, P < 0.001). The lens thickness increased significantly from 3.723 ± 0.237 mm to 3.963 ± 0.234 mm (P < 0.001). The vitreous length decreased significantly from 17.129 ± 0.864 mm to 17.057± 0.848 mm (P < 0.001). AL was 24.519 ± 0.917 mm at the rest state and increased to 24.545±0.915 mm with +6 D accommodation stimulus. The elongated AL of 26.1 ± 13.4 μm between the rest and accommodative states was significant (P < 0.001). CONCLUSIONS During accommodation, whole eye axial biometry changed, including a decrease in ACD and vitreous length, and an increase in lens thickness and AL. UL-OCT provides an alternative method that is suitable for full eye biometry during accommodation. PMID:24487051

  9. Anterior Eye Imaging with Optical Coherence Tomography

    NASA Astrophysics Data System (ADS)

    Huang, David; Li, Yan; Tang, Maolong

    The development of corneal and anterior segment optical coherence tomography (OCT) technology has advanced rapidly in recently years. The scan geometry and imaging wavelength are both important choices to make in designing anterior segment OCT systems. Rectangular scan geometry offers the least image distortion and is now used in most anterior OCT systems. The wavelength of OCT light source affects resolution and penetration. An optimal choice of the OCT imaging wavelength (840, 1,050, or 1,310 nm) depends on the application of interest. Newer generation Fourier-domain OCT technology can provide scan speed 100-1000 times faster than the time-domain technology. Various commercial anterior OCT systems are available on the market. A wide spectrum of diagnostic and surgical applications using anterior segment OCT had been investigated, including mapping of corneal and epithelial thicknesses, keratoconus screening, measuring corneal refractive power, corneal surgery planning and evaluation in LASIK, intracorneal ring implantation, assessment of angle closure glaucoma, anterior chamber biometry and intraocular lens implants, intraocular lens power calculation, and eye bank donor cornea screening.

  10. Optical clearing of skin using flash lamp-induced enhancement of epidermal permeability.

    PubMed

    Tuchin, V V; Altshuler, G B; Gavrilova, A A; Pravdin, A B; Tabatadze, D; Childs, J; Yaroslavsky, I V

    2006-10-01

    Strong light scattering in skin prevents precise targeting of optical energy in therapeutic and diagnostic applications. Optical immersion based on matching refractive index of scattering centers with that of surrounding matter through introduction of an exogenous index-matching agent can alleviate the problem. However, slow diffusion of the index-matching agent through skin barrier makes practical implementation of this approach difficult. We propose a method of accelerating penetration of the index-matching compounds by enhancing skin permeability through creating a lattice of micro-zones (islets) of limited thermal damage in the stratum corneum (SC). A flash lamp (intense pulsed light) system and an island mask with a pattern of absorbing centers (center size approximately 75-120 microm, lattice pitch approximately 450-500 microm) were used to create the lattice of islets of damage (LID). Index-matching agents, such as glucose solution, propylene glycol solution, and glycerol solution, were applied. Experimental results of optical clearing ex vivo rat and pig skin, and ex vivo and in vivo human skin are presented. Optical transmission spectra of the skin samples with LID were measured during some 2 hours after application of index-matching chemical agents. In order to assess and compare the clearing rate under different treatment and clearing agents we calculated the quantity that we call "relative transmittance": T(rel) = I(t)(lambda)/I(0)(lambda), were I(t)(lambda) is the intensity measured at elapsed time t. The dynamics of relative transmittance of skin samples at 470 and 650 nm shows that the implementation of limited thermal damage technique leads to a 3-10-fold increase of optical clearing (rise of transmittance) rate compared to the results obtained when the samples were treated with high-intensity light pulses but without the use of island damage mask (IDM). It was observed from the plotted spectra of relative transmittance that the maximum increase of

  11. Comparison of peripapillary retinal nerve fiber layer loss and visual outcome in fellow eyes following sequential bilateral non-arteritic anterior ischemic optic neuropathy.

    PubMed

    Dotan, Gad; Kesler, Anat; Naftaliev, Elvira; Skarf, Barry

    2015-05-01

    To report on the correlation of structural damage to the axons of the optic nerve and visual outcome following bilateral non-arteritic anterior ischemic optic neuropathy. A retrospective review of the medical records of 25 patients with bilateral sequential non-arteritic anterior ischemic optic neuropathy was performed. Outcome measures were peripapillary retinal nerve fiber layer thickness measured with the Stratus optical coherence tomography scanner, visual acuity and visual field loss. Median peripapillary retinal nerve fiber layer (RNFL) thickness, mean deviation (MD) of visual field, and visual acuity of initially involved NAION eyes (54.00 µm, -17.77 decibels (dB), 0.4, respectively) were comparable to the same parameters measured following development of second NAION event in the other eye (53.70 µm, p = 0.740; -16.83 dB, p = 0.692; 0.4, p = 0.942, respectively). In patients with bilateral NAION, there was a significant correlation of peripapillary RNFL thickness (r = 0.583, p = 0.002) and MD of the visual field (r = 0.457, p = 0.042) for the pairs of affected eyes, whereas a poor correlation was found in visual acuity of these eyes (r = 0.279, p = 0.176). Peripapillary RNFL thickness following NAION was positively correlated with MD of visual field (r = 0.312, p = 0.043) and negatively correlated with logMAR visual acuity (r = -0.365, p = 0.009). In patients who experience bilateral NAION, the magnitude of RNFL loss is similar in each eye. There is a greater similarity in visual field loss than in visual acuity between the two affected eyes with NAION of the same individual.

  12. Enantiomer analysis of chiral carboxylic acids by AIE molecules bearing optically pure aminol groups.

    PubMed

    Zheng, Yan-Song; Hu, Yu-Jian; Li, Dong-Mi; Chen, Yi-Chang

    2010-01-15

    Pure enantiomers of carboxylic acids are a class of important biomolecules, chiral drugs, chiral reagents, etc. Analysis of the enantiomers usually needs expensive instrument or complex chiral receptors. However, to develop simple and reliable methods for the enantiomer analysis of acids is difficult. In this paper, chiral recognition of 2,3-dibenzoyltartaric acid and mandelic acid was first carried out by aggregation-induced emission molecules bearing optically pure aminol group, which was easily synthesized. The chiral recognition is not only seen by naked eyes but also measured by fluorophotometer. The difference of fluorescence intensity between the two enantiomers of the acids aroused by the aggregation-induced emission molecules was up to 598. The chiral recognition could be applied to quantitative analysis of enantiomer content of chiral acids. More chiral AIE amines need to be developed for enantiomer analysis of more carboxylic acids.

  13. Enhanced depth imaging optical coherence tomography of choroidal metastasis in 14 eyes.

    PubMed

    Al-Dahmash, Saad A; Shields, Carol L; Kaliki, Swathi; Johnson, Timothy; Shields, Jerry A

    2014-08-01

    To describe the imaging features of choroidal metastasis using enhanced depth imaging optical coherence tomography (EDI-OCT). This retrospective observational case series included 31 eyes with choroidal metastasis. Spectral domain EDI-OCT was performed using Heidelberg Spectralis HRA + OCT. The main outcome measures were imaging features by EDI-OCT. Of 31 eyes with choroidal metastasis imaged with EDI-OCT, 14 (45%) eyes displayed image detail suitable for study. The metastasis originated from carcinoma of the breast (n = 7, 50%), lung (n = 5, 36%), pancreas (n = 1, 7%), and thyroid gland (n = 1, 7%). The mean tumor basal diameter was 6.4 mm, and mean thickness was 2.3 mm by B-scan ultrasonography. The tumor location was submacular in 6 (43%) eyes and extramacular in 8 (57%) eyes. By EDI-OCT, the mean tumor thickness was 987 μm. The most salient EDI-OCT features of the metastasis included anterior compression/obliteration of the overlying choriocapillaris (n = 13, 93%), an irregular (lumpy bumpy) anterior contour (n = 9, 64%), and posterior shadowing (n = 12, 86%). Overlying retinal pigment epithelial abnormalities were noted (n = 11, 78%). Outer retinal features included structural loss of the interdigitation of the cone outer segment tips (n = 9, 64%), the ellipsoid portion of photoreceptors (n = 8, 57%), external limiting membrane (n = 4, 29%), outer nuclear layer (n = 1, 7%), and outer plexiform layer (n = 1, 7%). The inner retinal layers (inner nuclear layer to nerve fiber layer) were normal. Subretinal fluid (n = 11, 79%), subretinal lipofuscin pigment (n = 1, 7%), and intraretinal edema (n = 2, 14%) were identified. The EDI-OCT of choroidal metastasis shows a characteristic lumpy bumpy anterior tumor surface and outer retinal layer disruption with preservation of inner retinal layers.

  14. The October 2014 United States Treasury bond flash crash and the contributory effect of mini flash crashes

    PubMed Central

    Levine, Zachary S.; Floridi, Luciano

    2017-01-01

    We investigate the causal uncertainty surrounding the flash crash in the U.S. Treasury bond market on October 15, 2014, and the unresolved concern that no clear link has been identified between the start of the flash crash at 9:33 and the opening of the U.S. equity market at 9:30. We consider the contributory effect of mini flash crashes in equity markets, and find that the number of equity mini flash crashes in the three-minute window between market open and the Treasury Flash Crash was 2.6 times larger than the number experienced in any other three-minute window in the prior ten weekdays. We argue that (a) this statistically significant finding suggests that mini flash crashes in equity markets both predicted and contributed to the October 2014 U.S. Treasury Bond Flash Crash, and (b) mini-flash crashes are important phenomena with negative externalities that deserve much greater scholarly attention. PMID:29091931

  15. Characterizing Intraorbital Optic Nerve Changes on Diffusion Tensor Imaging in Thyroid Eye Disease Before Dysthyroid Optic Neuropathy.

    PubMed

    Lee, Hwa; Lee, Young Hen; Suh, Sang-Il; Jeong, Eun-Kee; Baek, Sehyun; Seo, Hyung Suk

    The aim of this study was to determine whether the optic nerve is affected by thyroid eye disease (TED) before the development of dysthyroid optic neuropathy with diffusion-tensor imaging (DTI). Twenty TED patients and 20 controls were included. The mean, axial, and radial diffusivities and fractional anisotropy (FA) value were measured at the optic nerves in DTI. Extraocular muscle diameters were measured on computed tomography. The diffusivities and FA of the optic nerves were compared between TED and controls and between active and inactive stages of TED. The correlations between these DTI parameters and the clinical features were determined. The mean, axial, and radial diffusivities were lower in TED compared with the controls (P < 0.05). In contrast, FA was higher in TED (P = 0.001). Radial diffusivity was lower in the active stage of TED than the inactive stage (P = 0.035). The FA was higher in the TED group than in the control group (P = 0.021) and was positively correlated with clinical activity score (r = 0.364, P = 0.021), modified NOSPECS score (r = 0.469, P = 0.002), and extraocular muscle thickness (r = 0.325, P = 0.041) in the TED group. Radial diffusivity was negatively correlated with modified NOSPECS score (r = -0.384, P = 0.014), and axial diffusivity was positively correlated with exophthalmos degree (r = 0.363, P = 0.025). The diffusivities and FA reflected changes in the optic nerve before dysthyroid optic neuropathy in TED. The FA, in particular, reflected TED activity and severity.

  16. Versatile optical coherence tomography for imaging the human eye

    PubMed Central

    Tao, Aizhu; Shao, Yilei; Zhong, Jianguang; Jiang, Hong; Shen, Meixiao; Wang, Jianhua

    2013-01-01

    We demonstrated the feasibility of a CMOS-based spectral domain OCT (SD-OCT) for versatile ophthalmic applications of imaging the corneal epithelium, limbus, ocular surface, contact lens, crystalline lens, retina, and full eye in vivo. The system was based on a single spectrometer and an alternating reference arm with four mirrors. A galvanometer scanner was used to switch the reference beam among the four mirrors, depending on the imaging application. An axial resolution of 7.7 μm in air, a scan depth of up to 37.7 mm in air, and a scan speed of up to 70,000 A-lines per second were achieved. The approach has the capability to provide high-resolution imaging of the corneal epithelium, contact lens, ocular surface, and tear meniscus. Using two reference mirrors, the zero delay lines were alternatively placed on the front cornea or on the back lens. The entire ocular anterior segment was imaged by registering and overlapping the two images. The full eye through the pupil was measured when the reference arm was switched among the four reference mirrors. After mounting a 60 D lens in the sample arm, this SD-OCT was used to image the retina, including the macula and optical nerve head. This system demonstrates versatility and simplicity for multi-purpose ophthalmic applications. PMID:23847729

  17. Flash characteristics of plasma induced by hypervelocity impact

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Kai; Beijing Automotive Technology Center, Beijing 100021; Long, Renrong, E-mail: longrenrong@bit.edu.cn, E-mail: qmzhang@bit.edu.cn

    2016-08-15

    Using a two-stage light gas gun, a series of hypervelocity impact experiments was conducted in which 6.4-mm-diameter spherical 2024-aluminum projectiles impact 23-mm-thick targets made of the same material at velocities of 5.0, 5.6, and 6.3 km/s. Both an optical pyrometer composed of six photomultiplier tubes and a spectrograph were used to measure the flash of the plasma during hypervelocity impact. Experimental results show that, at a projectile velocity of 6.3 km/s, the strong flash lasted about 10 μs and reached a temperature of 4300 K. Based on the known emission lines of AL I, spectral methods can provide the plasma electron temperature. An electron-temperaturemore » comparison between experiment and theoretical calculation indicates that single ionization and secondary ionization are the two main ionizing modes at velocities 5.0–6.3 km/s.« less

  18. Terrestrial gamma-ray flashes monitor demonstrator on CubeSat

    NASA Astrophysics Data System (ADS)

    Dániel, V.; Pína, L.; Inneman, A.; Zadražil, V.; Báča, T.; Platkevič, M.; Stehlíková, V.; Nentvich, O.; Urban, M.

    2016-09-01

    The CubeSat mission with the demonstrator of miniaturized X-ray telescope is presented. The paper presents one of the mission objectives of using the instrument for remote sensing of the Terrestrial Gamma-ray Flashes (TGFs). TGFs are intense sources of gamma-rays associated with lightning bolt activity and tropical thunderstorms. The measurement of TGFs exists and was measured by sounding rockets, high altitude balloons or several satellite missions. Past satellite missions were equipped with different detectors working from 10 keV up to 10 MeV. The RHESSI mission spectrum measurement of TGFs shows the maximum counts per second around 75 keV. The used detectors were in general big in volume and cannot be utilized by the CubeSat mission. The presented CubeSat is equipped with miniaturized X-ray telescope using the Timepix non-cooled pixel detector. The detector works between 3 and 60 keV in counting mode (dosimetry) or in spectrum mode with resolution 5 keV. The wide-field X-ray "Lobster-eye" optics/collimator (depending on energy) is used with a view angle of 3 degrees for the source location definition. The UV detectors with FOV 30 degrees and 1.5 degrees are added parallel with the optic as a part of the telescope. The telescope is equipped with software distinguishing between the photons and other particles. Using this software the TGF's detection is possible also in the field of South Atlantic anomaly. For the total ionization dose, the additional detector is used based on Silicone (12-60 keV) and CdTe (20 keV - 1 MeV). The presented instruments are the demonstrators suitable also for the astrophysical, sun and moon observation. The paper shows the details of TGF's observation modes, detectors details, data processing and handling system and mission. The CubeSat launch is planned to summer 2016.

  19. Development of a helmet-mounted PLZT thermal/flash protection system. [Protective goggles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, J.O. Jr.; Cutchen, J.T.; Pfoff, B.J.

    1976-01-01

    Sandia Laboratories is developing PLZT thermal/flash protective devices (TFPD's) goggles to prevent exposure and resultant eye damage from nuclear weapon detonations. The primary emphasis of the present program is to transfer technology and establish production capability for helmet-mounted PLZT/TFPD goggles for USAF flight crews, with a non-helmet-mounted configuration to follow. The first production units are anticipated in the fall of 1977. The operating principles of the PLZT/TFPD goggle device are briefly outlined, and the device configuration and operational characteristics are described.

  20. Reproducibility of retinal nerve fiber layer thickness measures using eye tracking in children with nonglaucomatous optic neuropathy.

    PubMed

    Rajjoub, Raneem D; Trimboli-Heidler, Carmelina; Packer, Roger J; Avery, Robert A

    2015-01-01

    To determine the intra- and intervisit reproducibility of circumpapillary retinal nerve fiber layer (RNFL) thickness measures using eye tracking-assisted spectral-domain optical coherence tomography (SD OCT) in children with nonglaucomatous optic neuropathy. Prospective longitudinal study. Circumpapillary RNFL thickness measures were acquired with SD OCT using the eye-tracking feature at 2 separate study visits. Children with normal and abnormal vision (visual acuity ≥ 0.2 logMAR above normal and/or visual field loss) who demonstrated clinical and radiographic stability were enrolled. Intra- and intervisit reproducibility was calculated for the global average and 9 anatomic sectors by calculating the coefficient of variation and intraclass correlation coefficient. Forty-two subjects (median age 8.6 years, range 3.9-18.2 years) met inclusion criteria and contributed 62 study eyes. Both the abnormal and normal vision cohort demonstrated the lowest intravisit coefficient of variation for the global RNFL thickness. Intervisit reproducibility remained good for those with normal and abnormal vision, although small but statistically significant increases in the coefficient of variation were observed for multiple anatomic sectors in both cohorts. The magnitude of visual acuity loss was significantly associated with the global (ß = 0.026, P < .01) and temporal sector coefficient of variation (ß = 0.099, P < .01). SD OCT with eye tracking demonstrates highly reproducible RNFL thickness measures. Subjects with vision loss demonstrate greater intra- and intervisit variability than those with normal vision. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Retina imaging system with adaptive optics for the eye with or without myopia

    NASA Astrophysics Data System (ADS)

    Li, Chao; Xia, Mingliang; Jiang, Baoguang; Mu, Quanquan; Chen, Shaoyuan; Xuan, Li

    2009-04-01

    An adaptive optics system for the retina imaging is introduced in the paper. It can be applied to the eye with myopia from 0 to 6 diopters without any adjustment of the system. A high-resolution liquid crystal on silicon (LCOS) device is used as the wave-front corrector. The aberration is detected by a Shack-Harmann wave-front sensor (HASO) that has a Root Mean Square (RMS) measurement accuracy of λ/100 ( λ = 0.633 μm). And an equivalent scale model eye is constructed with a short focal length lens (˜18 mm) and a diffuse reflection object (paper screen) as the retina. By changing the distance between the paper screen and the lens, we simulate the eye with larger diopters than 5 and the depth of field. The RMS value both before and after correction is obtained by the wave-front sensor. After correction, the system reaches the diffraction-limited resolution approximately 230 cycles/mm at the object space. It is proved that if the myopia is smaller than 6 diopters and the depth of field is between -40 and +50 mm, the system can correct the aberration very well.

  2. Evaluation of Optical Quality: Ocular Scattering and Aberrations in Eyes Implanted with Diffractive Multifocal or Monofocal Intraocular Lenses.

    PubMed

    Liao, Xuan; Lin, Jia; Tian, Jing; Wen, BaiWei; Tan, QingQing; Lan, ChangJun

    2018-06-01

    To compare objective optical quality, ocular scattering and aberrations of eyes implanted with an aspheric monofocal intraocular lens (IOL) or an aspheric apodized diffractive multifocal IOL three months after surgery. Prospective consecutive nonrandomized comparative cohort study. A total of 80 eyes from 57 cataract patients were bilaterally or unilaterally implanted with monofocal (AcrySof IQ SN60WF) or multifocal (AcrySof IQ ReSTOR SN6AD1) IOLs. Respectively, 40 eyes of 27 patients were implanted with monofocal IOLs, and 40 eyes of 30 patients were implanted with multifocal IOLs. Ocular high-order aberration (HOA) values were obtained using Hartmann-Shack aberrometer; objective scatter index (OSI), modulation transfer function (MTF) cutoff, Strehl ratio (SR), and contrast visual acuity OV at 100%, 20%, and 9% were measured using Objective Quality Analysis System II (OQAS II). Ocular aberrations performed similar in both groups (p > 0.05). However, significantly higher values of OSI and lower values of MTF cutoff, SR and OV were found in the SN6AD1 group (p < 0.05). Both ocular scattering and wave-front aberrations play essential role in retinal image quality, which may be overestimated when only aberrations were taken into account. Combining the effect of ocular scattering with HOA will result in a more accurate assessment of the visual and optical quality.

  3. Determination of the Global-Average Charge Moment of a Lightning Flash Using Schumann Resonances and the LIS/OTD Lightning Data

    NASA Astrophysics Data System (ADS)

    Boldi, Robert; Williams, Earle; Guha, Anirban

    2018-01-01

    In this paper, we use (1) the 20 year record of Schumann resonance (SR) signals measured at West Greenwich Rhode Island, USA, (2) the 19 year Lightning Imaging Sensor (LIS)/Optical Transient Detector (OTD) lightning data, and (3) the normal mode equations for a uniform cavity model to quantify the relationship between the observed Schumann resonance modal intensity and the global-average vertical charge moment change M (C km) per lightning flash. This work, by integrating SR measurements with satellite-based optical measurements of global flash rate, accomplishes this quantification for the first time. To do this, we first fit the intensity spectra of the observed SR signals to an eight-mode, three parameter per mode, (symmetric) Lorentzian line shape model. Next, using the LIS/OTD lightning data and the normal mode equations for a uniform cavity model, we computed the expected climatological-daily-average intensity spectra. We then regressed the observed modal intensity values against the expected modal intensity values to find the best fit value of the global-average vertical charge moment change of a lightning flash (M) to be 41 C km per flash with a 99% confidence interval of ±3.9 C km per flash, independent of mode. Mode independence argues that the model adequately captured the modal intensity, the most important fit parameter herein considered. We also tested this relationship for the presence of residual modal intensity at zero lightning flashes per second and found no evidence that modal intensity is significantly different than zero at zero lightning flashes per second, setting an upper limit to the amount of nonlightning contributions to the observed modal intensity.

  4. Acute Solar Retinopathy Imaged With Adaptive Optics, Optical Coherence Tomography Angiography, and En Face Optical Coherence Tomography.

    PubMed

    Wu, Chris Y; Jansen, Michael E; Andrade, Jorge; Chui, Toco Y P; Do, Anna T; Rosen, Richard B; Deobhakta, Avnish

    2018-01-01

    Solar retinopathy is a rare form of retinal injury that occurs after direct sungazing. To enhance understanding of the structural changes that occur in solar retinopathy by obtaining high-resolution in vivo en face images. Case report of a young adult woman who presented to the New York Eye and Ear Infirmary with symptoms of acute solar retinopathy after viewing the solar eclipse on August 21, 2017. Results of comprehensive ophthalmic examination and images obtained by fundus photography, microperimetry, spectral-domain optical coherence tomography (OCT), adaptive optics scanning light ophthalmoscopy, OCT angiography, and en face OCT. The patient was examined after viewing the solar eclipse. Visual acuity was 20/20 OD and 20/25 OS. The patient was left-eye dominant. Spectral-domain OCT images were consistent with mild and severe acute solar retinopathy in the right and left eye, respectively. Microperimetry was normal in the right eye but showed paracentral decreased retinal sensitivity in the left eye with a central absolute scotoma. Adaptive optics images of the right eye showed a small region of nonwaveguiding photoreceptors, while images of the left eye showed a large area of abnormal and nonwaveguiding photoreceptors. Optical coherence tomography angiography images were normal in both eyes. En face OCT images of the right eye showed a small circular hyperreflective area, with central hyporeflectivity in the outer retina of the right eye. The left eye showed a hyperreflective lesion that intensified in area from inner to middle retina and became mostly hyporeflective in the outer retina. The shape of the lesion on adaptive optics and en face OCT images of the left eye corresponded to the shape of the scotoma drawn by the patient on Amsler grid. Acute solar retinopathy can present with foveal cone photoreceptor mosaic disturbances on adaptive optics scanning light ophthalmoscopy imaging. Corresponding reflectivity changes can be seen on en face OCT, especially

  5. High resolution macroscopy (HRMac) of the eye using nonlinear optical imaging

    NASA Astrophysics Data System (ADS)

    Winkler, Moritz; Jester, Bryan E.; Nien-Shy, Chyong; Chai, Dongyul; Brown, Donald J.; Jester, James V.

    2010-02-01

    Non-linear optical (NLO) imaging using femtosecond lasers provides a non-invasive means of imaging the structural organization of the eye through the generation of second harmonic signals (SHG). While NLO imaging is able to detect collagen, the small field of view (FoV) limits the ability to study how collagen is structurally organized throughout the larger tissue. To address this issue we have used computed tomography on optical and mechanical sectioned tissue to greatly expand the FoV and provide high resolution macroscopic (HRMac) images that cover the entire tissue (cornea and optic nerve head). Whole, fixed cornea (13 mm diameter) or optic nerve (3 mm diameter) were excised and either 1) embedded in agar and sectioned using a vibratome (200-300 um), or 2) embedded in LR White plastic resin and serially sectioned (2 um). Vibratome and plastic sections were then imaged using a Zeiss LSM 510 Meta and Chameleon femtosecond laser to generate NLO signals and assemble large macroscopic 3-dimensional tomographs with high resolution that varied in size from 9 to 90 Meg pixels per plane having a resolution of 0.88 um lateral and 2.0 um axial. 3-D reconstructions allowed for regional measurements within the cornea and optic nerve to quantify collagen content, orientation and organization over the entire tissue. We conclude that NLO based tomography to generate HRMac images provides a powerful new tool to assess collagen structural organization. Biomechanical testing combined with NLO tomography may provide new insights into the relationship between the extracellular matrix and tissue mechanics.

  6. Phenomenology of the sound-induced flash illusion.

    PubMed

    Abadi, Richard V; Murphy, Jonathan S

    2014-07-01

    Past studies, using pairings of auditory tones and visual flashes, which were static and coincident in space but variable in time, demonstrated errors in judging the temporal patterning of the visual flashes-the sound-induced flash illusion. These errors took one of the two forms: under-reporting (sound-induced fusion) or over-reporting (sound-induced fission) of the flash numbers. Our study had three objectives: to examine the robustness of both illusions and to consider the effects of stimulus set and response bias. To this end, we used an extended range of fixed spatial location flash-tone pairings, examined stimuli that were variable in space and time and measured confidence in judging flash numbers. Our results indicated that the sound-induced flash illusion is a robust percept, a finding underpinned by the confidence measures. Sound-induced fusion was found to be more robust than sound-induced fission and a most likely outcome when high numbers of flashes were incorporated within an incongruent flash-tone pairing. Conversely, sound-induced fission was the most likely outcome for the flash-tone pairing which contained two flashes. Fission was also shown to be strongly driven by stimuli confounds such as categorical boundary conditions (e.g. flash-tone pairings with ≤2 flashes) and compressed response options. These findings suggest whilst both fission and fusion are associated with 'auditory driving', the differences in the occurrence and strength of the two illusions not only reflect the separate neuronal mechanisms underlying audio and visual signal processing, but also the test conditions that have been used to investigate the sound-induced flash illusion.

  7. Jitter-correction for IR/UV-XUV pump-probe experiments at the FLASH free-electron laser

    DOE PAGES

    Savelyev, Evgeny; Boll, Rebecca; Bomme, Cedric; ...

    2017-04-10

    In pump-probe experiments employing a free-electron laser (FEL) in combination with a synchronized optical femtosecond laser, the arrival-time jitter between the FEL pulse and the optical laser pulse often severely limits the temporal resolution that can be achieved. Here, we present a pump-probe experiment on the UV-induced dissociation of 2,6-difluoroiodobenzene C 6H 3F 2I) molecules performed at the FLASH FEL that takes advantage of recent upgrades of the FLASH timing and synchronization system to obtain high-quality data that are not limited by the FEL arrival-time jitter. Here, we discuss in detail the necessary data analysis steps and describe the originmore » of the time-dependent effects in the yields and kinetic energies of the fragment ions that we observe in the experiment.« less

  8. Ground- and Space-based Observations of Horizontally-extensive Lightning Flashes

    NASA Astrophysics Data System (ADS)

    Zhang, D.; Cummins, K. L.; Bitzer, P. M.

    2017-12-01

    Horizontally-extensive lightning flashes occur frequently in association with mature and late phases of multicellular thunderstorms, both in trailing stratiform regions and horizontally-extensive anvils. The spatial relationship between these flashes and the parent cloud volume is of importance for space launch operational decision making, and is of broader scientific interest. Before this question can be accurately addressed, there is a need to understand the degree to which current lightning observation systems can depict the spatial extent of these long flashes. In this ongoing work, we will intercompare the depiction of horizontally-extensive flashes using several ground-based lightning locating systems (LLSs) located at Kennedy Space Center (KSC) with space-based observations observed by the recently-launched Geostationary Lightning Mapper (GLM) onboard the GOES-16 satellite. Ground-based datasets include the KSC Lightning Mapping Array (KSCLMA), the operational narrowband digital interferometer network MERLIN, and the combined cloud-to-ground and cloud lightning dataset produced by the U.S. National Lightning Detection Network (NLDN). The KSCLMA system is a network of VHF time-of-arrival sensors that preferentially report breakdown processes, and MERLIN is a network of VHF interferometers that point to the discharges in the horizontal plane. Observations to date indicate that MERLIN and the KSCSLMA provide similar overall descriptions of the spatial and temporal extent of these flashes, while the NLDN does not provide adequate spatial mapping of these flashes. The KSC LMA system has much better location accuracy, and provides excellent 3-dimensional representation within 100 km of KSC. It also has sufficient sensitivity to provide 2-dimensional flash mapping within 250 km of KSC. The MERLIN system provides a more-detailed representation of fast leader propagation (in 2 dimensions) with 100 km of KSC. Earlier work during the CHUVA campaign in Brazil with

  9. Accessing the genomic effects of naked nanoceria in murine neuronal cells.

    PubMed

    Lee, Tin-Lap; Raitano, Joan M; Rennert, Owen M; Chan, Siu-Wai; Chan, Wai-Yee

    2012-07-01

    Cerium oxide nanoparticles (nanoceria) are engineered nanoparticles whose versatility is due to their unique redox properties. We and others have demonstrated that naked nanoceria can act as antioxidants to protect cells against oxidative damage. Although the redox properties may be beneficial, the genome-wide effects of nanoceria on gene transcription and associated biological processes remain elusive. Here we applied a functional genomic approach to examine the genome-wide effects of nanoceria on global gene transcription and cellular functions in mouse neuronal cells. Importantly, we demonstrated that nanoceria induced chemical- and size-specific changes in the murine neuronal cell transcriptome. The nanoceria contributed more than 83% of the population of uniquely altered genes and were associated with a unique spectrum of genes related to neurological disease, cell cycle control, and growth. These observations suggest that an in-depth assessment of potential health effects of naked nanoceria and other naked nanoparticles is both necessary and imminent. Cerium oxide nanoparticles are important antioxidants, with potential applications in neurodegenerative conditions. This team of investigators demonstrated the genomic effects of nanoceria, showing that it induced chemical- and size-specific changes in the murine neuronal cell transcriptome. Published by Elsevier Inc.

  10. Laser speckle flowgraphy for differentiating between nonarteritic ischemic optic neuropathy and anterior optic neuritis.

    PubMed

    Maekubo, Tomoyuki; Chuman, Hideki; Nao-I, Nobuhisa

    2013-07-01

    The aim of this study was to investigate the usefulness of laser speckle flowgraphy (LSFG) for the differentiation of acute nonarteritic ischemic optic neuropathy (NAION) from anterior optic neuritis (ON). To investigate blood flow in the optic disc under normal conditions, NAION, and anterior ON, we compared the tissue blood flow of the right eye with that of the left eye in the control group, and that of the affected eye with that of the unaffected eye in the NAION and anterior ON groups. In the normal control group, the tissue blood flow did not significantly differ between the right and left eyes. In the NAION group, all 6 patients had decreased optic disc blood flow in the NAION eye when compared with the unaffected eye. By contrast, in the anterior ON group, all 6 patients had increased optic disc blood flow in the anterior ON eye when compared with the unaffected eye. In the NAION group, the mean blur rate (MBR) of the affected eyes was 29.5 % lower than that of the unaffected eyes. In the anterior ON group, the MBR of the affected eyes was 15.9 % higher than that of the unaffected eyes. LSFG could be useful in differentiating between NAION and anterior ON. In addition, this imaging technique saves time and is noninvasive.

  11. Light transmission and preference of eye patches for occlusion treatment.

    PubMed

    Heo, Hwan; Park, Jung Won; Park, Sang Woo

    2013-01-01

    To investigate light transmission and preference for six eye patches for occlusion therapy. Six patches were examined, including; Ortopad Fun Pack, Ortopad Flesh, Kawamoto A-1, Kawamoto A-2, 3M Opticlude, and Everade Eye Guard. The size and the presence of a light blocking pad of patches were investigated. The amount of light transmitted through the patches was evaluated, using a digital light meter and a model eye, in three different environments; indoors with fluorescent light, outdoors on a sunny day, and strong light from illuminator. After patching the normal eye, the flash visual evoked potential (VEP) was measured. Thirty patients with amblyopia or horizontal strabismus, who received occlusion therapy as initial treatment, were included. After using all six patches, patients completed a 7-item questionnaire regarding the patch preference for size, color and shape, adhesive power, pain with removal, skin irritation after removing patch, parent's preference and overall opinion. All patches had a light-blocking pad, except the 3M Nexcare. Ortopad had the strongest light blocking power in the three environments, and the 3M Nexcare had the weakest power. In flash VEP, Ortopad and Kawamoto patches showed flat, but 3M Nexcare and Everade Eye Guard showed normal response. There were significant preferential differences among the patches in all the items of the questionnaire (P<0.05). In comparison between the patches respectively, 3M Nexcare received the lowest satisfaction in pain when removing a patch and skin irritation after removing a patch. Kawamoto A-2 received the lowest score in the overall satisfaction. We found differences in the light-blocking power and in the preference of the various patches for the occlusion treatment. This is a pilot study regarding only characteristics and preferences of patches. Further clinical studies regarding the relationship between characteristics or preferences of patches and outcomes of occlusion treatment are needed.

  12. Hydrothermal crystal growth, piezoelectricity, and triboluminescence of KNaNbOF{sub 5}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Kelvin B.; Edwards, Bryce W.; Frazer, Laszlo

    Single crystals of the noncentrosymmetric KNaNbOF{sub 5} polymorph were grown for piezoelectric and triboluminescent measurements. Piezoelectric measurements yielded a d{sub 33} value of ±6.3 pCN{sup −1} and an effective electromechanical coupling coefficient of up to 0.1565 in the frequency range 1960–2080 kHz. Crystals of KNaNbOF{sub 5} were found to exhibit a strong triboluminscence effect visible to the naked eye as blue sparks when crystals are crushed. This triboluminescence effect is uncommon in that it is likely independent from both the piezoelectric effect and atmospheric electrical discharge. Instead, triboluminescence may originate from crystal defects or be related to an electroluminescence effect.more » - Graphical abstract: An optical emission visible to the naked eye as blue sparks is observed when KNaNbOF{sub 5} single crystals are fractured. - Highlights: • Single crystals of KNaNbOF{sub 5} were grown under hydrothermal conditions. • Piezoelectric and triboluminescent properties were characterized. • Piezoelectric measurements yielded a d{sub 33} value of ±pCN{sup −1}. • KNaNbOF{sub 5} exhibits strong triboluminscence visible to the naked eye as blue sparks.« less

  13. Statistical Evolution of the Lightning Flash

    NASA Astrophysics Data System (ADS)

    Zoghzoghy, F. G.; Cohen, M.; Said, R.; Inan, U. S.

    2012-12-01

    Natural lightning is one of the most fascinating and powerful electrical processes on Earth. To date, the physics behind this natural phenomenon are not fully understood, due primarily to the difficulty of obtaining measurements inside thunderstorms and to the wide range of timescales involved (from nanoseconds to seconds). Our aim is to use accurate lightning geo-location data from the National Lightning Detection Network (NLDN) to study statistical patterns in lightning, taking advantage of the fact that millions of lightning flashes occur around the globe every day. We present two sets of results, one involving the patterns of flashes in a storm, and a second involving the patterns of strokes in a flash. These patterns can provide a surrogate measure of the timescales and the spatial extents of the underlying physical processes. First, we study the timescales of charge buildup inside thunderstorms. We find that, following a lightning flash, the probability of another neighboring flash decreases and takes tens of seconds to recover. We find that this suppression effect is a function of flash type, stroke peak current, cloud-to-ground (CG) stroke multiplicity, and other lightning and geographical parameters. We find that the probabilities of subsequent flashes are more suppressed following oceanic lightning, or following flashes with higher peak currents and/or higher multiplicities (for CG flashes). Second, we use NLDN data to study the evolution of the strokes within a CG flash. A CG flash typically includes multiple return strokes, which can occur in the same channel or in multiple channels within a few kilometers. We cluster NLDN stroke data into flashes and produce the probability density function of subsequent strokes as a function of distance and time-delays relative to the previous stroke. Using this technique, we investigate processes which occur during the CG lightning flash with nanosecond to millisecond timescales. For instance, our results suggest

  14. FLASH LIDAR Based Relative Navigation

    NASA Technical Reports Server (NTRS)

    Brazzel, Jack; Clark, Fred; Milenkovic, Zoran

    2014-01-01

    Relative navigation remains the most challenging part of spacecraft rendezvous and docking. In recent years, flash LIDARs, have been increasingly selected as the go-to sensors for proximity operations and docking. Flash LIDARS are generally lighter and require less power that scanning Lidars. Flash LIDARs do not have moving parts, and they are capable of tracking multiple targets as well as generating a 3D map of a given target. However, there are some significant drawbacks of Flash Lidars that must be resolved if their use is to be of long-term significance. Overcoming the challenges of Flash LIDARs for navigation-namely, low technology readiness level, lack of historical performance data, target identification, existence of false positives, and performance of vision processing algorithms as intermediaries between the raw sensor data and the Kalman filter-requires a world-class testing facility, such as the Lockheed Martin Space Operations Simulation Center (SOSC). Ground-based testing is a critical step for maturing the next-generation flash LIDAR-based spacecraft relative navigation. This paper will focus on the tests of an integrated relative navigation system conducted at the SOSC in January 2014. The intent of the tests was to characterize and then improve the performance of relative navigation, while addressing many of the flash LIDAR challenges mentioned above. A section on navigation performance and future recommendation completes the discussion.

  15. Retinal cross talk in the mammalian visual system

    PubMed Central

    Tang, Xiaolan; Tzekov, Radouil

    2016-01-01

    The existence and functional relevance of efferent optic nerve fibers in mammals have long been debated. While anatomical evidence for cortico-retinal and retino-retinal projections is substantial, physiological evidence is lacking, as efferent fibers are few in number and are severed in studies of excised retinal tissue. Here we show that interocular connections contribute to retinal bioelectrical activity in adult mammals. Full-field flash electroretinograms (ERGs) were recorded from one or both eyes of Brown-Norway rats under dark-adapted (n = 16) and light-adapted (n = 11) conditions. Flashes were confined to each eye by an opaque tube that blocked stray light. Monocular flashes evoked a small (5–15 μV) signal in the nonilluminated eye, which was named “crossed ERG” (xERG). The xERG began under dark-adapted conditions with a positive (xP1) wave that peaked at 70–90 ms and ended with slower negative (xN1) and positive (xP2) waves from 200 to 400 ms. xN1 was absent under light-adapted conditions. Injection of tetrodotoxin in either eye (n = 15) eliminated the xERG. Intraocular pressure elevation of the illuminated eye (n = 6) had the same effect. The treatments also altered the ERG b-wave in both eyes, and the alterations correlated with xERG disappearance. Optic nerve stimulation (n = 3) elicited a biphasic compound action potential in the nonstimulated nerve with 10- to 13-ms latency, implying that the xERG comes from slow-conducting (W type) fibers. Monocular dye application (n = 7) confirmed the presence of retino-retinal ganglion cells in adult rats. We conclude that mammalian eyes communicate directly with each other via a handful of optic nerve fibers. The cross talk alters retinal activity in rats, and perhaps other animals. PMID:26984426

  16. Visual field defects of the contralateral eye of non-arteritic ischemic anterior optic neuropathy: are they related to sleep apnea?

    PubMed

    Aptel, Florent; Aryal-Charles, Nischal; Tamisier, Renaud; Pépin, Jean-Louis; Lesoin, Antoine; Chiquet, Christophe

    2017-06-01

    To evaluate whether obstructive sleep apnea (OSA) is responsible for the visual field defects found in the fellow eyes of patients with non-arteritic ischemic optic neuropathy (NAION). Prospective cross-sectional study. The visual fields of the fellow eyes of NAION subjects with OSA were compared to the visual fields of control OSA patients matched for OSA severity. All patients underwent comprehensive ophthalmological and general examination including Humphrey 24.2 SITA-Standard visual field and polysomnography. Visual field defects were classified according the Ischemic Optic Neuropathy Decompression Trial (IONDT) classification. From a cohort of 78 consecutive subjects with NAION, 34 unaffected fellow eyes were compared to 34 control eyes of subjects matched for OSA severity (apnea-hypopnea index [AHI] 35.5 ± 11.6 vs 35.4 ± 9.4 events per hour, respectively, p = 0.63). After adjustment for age and body mass index, all visual field parameters were significantly different between the NAION fellow eyes and those of the control OSA groups, including mean deviation (-4.5 ± 3.7 vs -1.3 ± 1.8 dB, respectively, p < 0.05), visual field index (91.6 ± 10 vs 97.4 ± 3.5%, respectively, p = 0.002), pattern standard deviation (3.7 ± 2.3 vs 2.5 ± 2 dB, respectively, p = 0.015), and number of subjects with at least one defect on the IONDT classification (20 vs 10, respectively, p < 0.05). OSA alone does not explain the visual field defects frequently found in the fellow eyes of NAION patients.

  17. NIR small arms muzzle flash

    NASA Astrophysics Data System (ADS)

    Montoya, Joseph; Kennerly, Stephen; Rede, Edward

    2010-04-01

    Utilization of Near-Infrared (NIR) spectral features in a muzzle flash will allow for small arms detection using low cost silicon (Si)-based imagers. Detection of a small arms muzzle flash in a particular wavelength region is dependent on the intensity of that emission, the efficiency of source emission transmission through the atmosphere, and the relative intensity of the background scene. The NIR muzzle flash signature exists in the relatively large Si spectral response wavelength region of 300 nm-1100 nm, which allows for use of commercial-off-the-shelf (COTS) Si-based detectors. The alkali metal origin of the NIR spectral features in the 7.62 × 39-mm round muzzle flash is discussed, and the basis for the spectral bandwidth is examined, using a calculated Voigt profile. This report will introduce a model of the 7.62 × 39-mm NIR muzzle flash signature based on predicted source characteristics. Atmospheric limitations based on NIR spectral regions are investigated in relation to the NIR muzzle flash signature. A simple signal-to-clutter ratio (SCR) metric is used to predict sensor performance based on a model of radiance for the source and solar background and pixel registered image subtraction.

  18. Menopausal Hot Flashes and White Matter Hyperintensities

    PubMed Central

    Thurston, Rebecca C.; Aizenstein, Howard J.; Derby, Carol A.; Sejdić, Ervin; Maki, Pauline M.

    2015-01-01

    Objective Hot flashes are the classic menopausal symptom. Emerging data links hot flashes to cardiovascular disease (CVD) risk, yet how hot flashes are related to brain health is poorly understood. We examined the relationship between hot flashes - measured via physiologic monitor and self-report - and white matter hyperintensities (WMH) among midlife women. Methods Twenty midlife women ages 40-60 without clinical CVD, with their uterus and both ovaries, and not taking hormone therapy were recruited. Women underwent 24 hours of ambulatory physiologic and diary hot flash monitoring to quantify hot flashes; magnetic resonance imaging to assess WMH burden; 72 hours of actigraphy and questionnaires to quantify sleep; and a blood draw, questionnaires, and physical measures to quantify demographics and CVD risk factors. Test of a priori hypotheses regarding relations between physiologically-monitored and self-reported wake and sleep hot flashes and WMH were conducted in linear regression models. Results More physiologically-monitored hot flashes during sleep were associated with greater WMH, controlling for age, race, and body mass index [beta(standard error)=.0002 (.0001), p=.03]. Findings persisted controlling for sleep characteristics and additional CVD risk factors. No relations were observed for self-reported hot flashes. Conclusions More physiologically-monitored hot flashes during sleep were associated with greater WMH burden among midlife women free of clinical CVD. Results suggest that relations between hot flashes and CVD risk observed in the periphery may extend to the brain. Future work should consider the unique role of sleep hot flashes in brain health. PMID:26057822

  19. Gun muzzle blast and flash

    NASA Astrophysics Data System (ADS)

    Klingenberg, Guenter; Heimerl, Joseph M.

    A repository of fundamental experimental and analytical data concerning the complex phenomena associated with gun-muzzle blast and flash effects is presented, proceeding from gun muzzle signatures to modern gun-propulsion concepts, interior and transitional ballistics, and characterizations of blast-wave research and muzzle flash. Data are presented in support of a novel hypothesis which explains the ignition of secondary flash and elucidates the means for its suppression. Both chemical and mechanical (often competing) methods of flash suppression are treated. The historical work of Kesslau and Ladenburg is noted, together with French, British, Japanese and American research efforts and current techniques of experimental characterization for gun muzzle phenomena.

  20. Muzzle flash localization for the dismounted soldier

    NASA Astrophysics Data System (ADS)

    Kennedy Scott, Will

    2015-05-01

    The ability to accurately and rapidly know the precise location of enemy fire would be a substantial capability enhancement to the dismounted soldier. Acoustic gun-shot detections systems can provide an approximate bearing but it is desired to precisely know the location (direction and range) of enemy fire; for example to know from `which window' the fire is coming from. Funded by the UK MOD (via Roke Manor Research) QinetiQ is developing an imaging solution built around an InGaAs camera. This paper presents work that QinetiQ has undertaken on the Muzzle Flash Locator system. Key technical challenges that have been overcome are explained and discussed in this paper. They include; the design of the optical sensor and processing hardware to meet low size, weight and power requirements; the algorithm approach required to maintain sensitivity whilst rejecting false alarms from sources such as close passing insects and sun glint from scene objects; and operation on the move. This work shows that such a sensor can provide sufficient sensitivity to detect muzzle flash events to militarily significant ranges and that such a system can be combined with an acoustic gunshot detection system to minimize the false alarm rate. The muzzle flash sensor developed in this work operates in real-time and has a field of view of approximately 29° (horizontal) by 12° (vertical) with a pixel resolution of 0.13°. The work has demonstrated that extension to a sensor with realistic angular rotation rate is feasible.

  1. Naked mole-rat mortality rates defy Gompertzian laws by not increasing with age

    PubMed Central

    Ruby, J Graham; Smith, Megan

    2018-01-01

    The longest-lived rodent, the naked mole-rat (Heterocephalus glaber), has a reported maximum lifespan of >30 years and exhibits delayed and/or attenuated age-associated physiological declines. We questioned whether these mouse-sized, eusocial rodents conform to Gompertzian mortality laws by experiencing an exponentially increasing risk of death as they get older. We compiled and analyzed a large compendium of historical naked mole-rat lifespan data with >3000 data points. Kaplan-Meier analyses revealed a substantial portion of the population to have survived at 30 years of age. Moreover, unlike all other mammals studied to date, and regardless of sex or breeding-status, the age-specific hazard of mortality did not increase with age, even at ages 25-fold past their time to reproductive maturity. This absence of hazard increase with age, in defiance of Gompertz’s law, uniquely identifies the naked mole-rat as a non-aging mammal, confirming its status as an exceptional model for biogerontology. PMID:29364116

  2. Intact unconscious processing of eye contact in schizophrenia.

    PubMed

    Seymour, Kiley; Rhodes, Gillian; Stein, Timo; Langdon, Robyn

    2016-03-01

    The perception of eye gaze is crucial for social interaction, providing essential information about another person's goals, intentions, and focus of attention. People with schizophrenia suffer a wide range of social cognitive deficits, including abnormalities in eye gaze perception. For instance, patients have shown an increased bias to misjudge averted gaze as being directed toward them. In this study we probed early unconscious mechanisms of gaze processing in schizophrenia using a technique known as continuous flash suppression. Previous research using this technique to render faces with direct and averted gaze initially invisible reveals that direct eye contact gains privileged access to conscious awareness in healthy adults. We found that patients, as with healthy control subjects, showed the same effect: faces with direct eye gaze became visible significantly faster than faces with averted gaze. This suggests that early unconscious processing of eye gaze is intact in schizophrenia and implies that any misjudgments of gaze direction must manifest at a later conscious stage of gaze processing where deficits and/or biases in attributing mental states to gaze and/or beliefs about being watched may play a role.

  3. Adaptive optics scanning laser ophthalmoscope using liquid crystal on silicon spatial light modulator: Performance study with involuntary eye movement

    NASA Astrophysics Data System (ADS)

    Huang, Hongxin; Toyoda, Haruyoshi; Inoue, Takashi

    2017-09-01

    The performance of an adaptive optics scanning laser ophthalmoscope (AO-SLO) using a liquid crystal on silicon spatial light modulator and Shack-Hartmann wavefront sensor was investigated. The system achieved high-resolution and high-contrast images of human retinas by dynamic compensation for the aberrations in the eyes. Retinal structures such as photoreceptor cells, blood vessels, and nerve fiber bundles, as well as blood flow, could be observed in vivo. We also investigated involuntary eye movements and ascertained microsaccades and drifts using both the retinal images and the aberrations recorded simultaneously. Furthermore, we measured the interframe displacement of retinal images and found that during eye drift, the displacement has a linear relationship with the residual low-order aberration. The estimated duration and cumulative displacement of the drift were within the ranges estimated by a video tracking technique. The AO-SLO would not only be used for the early detection of eye diseases, but would also offer a new approach for involuntary eye movement research.

  4. The Columbia Thyroid Eye Disease-Compressive Optic Neuropathy Formula.

    PubMed

    Callahan, Alison B; Campbell, Ashley A; Oropesa, Susel; Baraban, Aryeh; Kazim, Michael

    2018-06-13

    Diagnosing thyroid eye disease-compressive optic neuropathy (TED-CON) is challenging, particularly in cases lacking a relative afferent pupillary defect. Large case series of TED-CON patients and accessible diagnostic tools are lacking in the current literature. This study aims to create a mathematical formula that accurately predicts the presence or absence of CON based on the most salient clinical measures of optic neuropathy. A retrospective case series compares 108 patients (216 orbits) with either unilateral or bilateral TED-CON and 41 age-matched patients (82 orbits) with noncompressive TED. Utilizing clinical variables assessing optic nerve function and/or risk of compressive disease, and with the aid of generalized linear regression modeling, the authors create a mathematical formula that weighs the relative contribution of each clinical variable in the overall prediction of CON. Data from 213 orbits in 110 patients derived the formula: y = -0.69 + 2.58 × (afferent pupillary defect) - 0.31 × (summed limitation of ductions) - 0.2 × (mean deviation on Humphrey visual field testing) - 0.02 × (% color plates). This accurately predicted the presence of CON (y > 0) versus non-CON (y < 0) in 82% of cases with 83% sensitivity and 81% specificity. When there was no relative afferent pupillary defect, which was the case in 63% of CON orbits, the formula correctly predicted CON in 78% of orbits with 73% sensitivity and 83% specificity. The authors developed a mathematical formula, the Columbia TED-CON Formula (CTD Formula), that can help guide clinicians in accurately diagnosing TED-CON, particularly in the presence of bilateral disease and when no relative afferent pupillary defect is present.

  5. Hold-up power supply for flash memory

    NASA Technical Reports Server (NTRS)

    Ott, William E. (Inventor)

    2004-01-01

    A hold-up power supply for flash memory systems is provided. The hold-up power supply provides the flash memory with the power needed to temporarily operate when a power loss exists. This allows the flash memory system to complete any erasures and writes, and thus allows it to shut down gracefully. The hold-up power supply detects when a power loss on a power supply bus is occurring and supplies the power needed for the flash memory system to temporally operate. The hold-up power supply stores power in at least one capacitor. During normal operation, power from a high voltage supply bus is used to charge the storage capacitors. When a power supply loss is detected, the power supply bus is disconnected from the flash memory system. A hold-up controller controls the power flow from the storage capacitors to the flash memory system. The hold-up controller uses feedback to assure that the proper voltage is provided from the storage capacitors to the flash memory system. This power supplied by the storage capacitors allows the flash memory system to complete any erasures and writes, and thus allows the flash memory system to shut down gracefully.

  6. Eye Choice for Acquisition of Targets in Alternating Strabismus

    PubMed Central

    Economides, John R.; Adams, Daniel L.

    2014-01-01

    In strabismus, potentially either eye can inform the brain about the location of a target so that an accurate saccade can be made. Sixteen human subjects with alternating exotropia were tested dichoptically while viewing stimuli on a tangent screen. Each trial began with a fixation cross visible to only one eye. After the subject fixated the cross, a peripheral target visible to only one eye flashed briefly. The subject's task was to look at it. As a rule, the eye to which the target was presented was the eye that acquired the target. However, when stimuli were presented in the far nasal visual field, subjects occasionally performed a “crossover” saccade by placing the other eye on the target. This strategy avoided the need to make a large adducting saccade. In such cases, information about target location was obtained by one eye and used to program a saccade for the other eye, with a corresponding latency increase. In 10/16 subjects, targets were presented on some trials to both eyes. Binocular sensory maps were also compiled to delineate the portions of the visual scene perceived with each eye. These maps were compared with subjects' pattern of eye choice for target acquisition. There was a correspondence between suppression scotoma maps and the eye used to acquire peripheral targets. In other words, targets were fixated by the eye used to perceive them. These studies reveal how patients with alternating strabismus, despite eye misalignment, manage to localize and capture visual targets in their environment. PMID:25355212

  7. Christoph Scheiner's eye studies.

    PubMed

    Daxecker, F

    1992-01-01

    Christoph Scheiner was born in 1573 or 1575. In 1595 he entered into the Order of the Jesuits; he died in 1650. In 1619 his book Oculus, dealing with the optics of the eye, appeared in Innsbruck. The invention of the telescope was of utmost importance for progress in astronomical and physical research. Scheiner himself built telescopes and discovered the sunspots. As a result, an unpleasant priority dispute with Galilei ensued. From 1624 onwards, Scheiner was in Rome, where his main work Rosa Ursina was published in 1630. A part of this book deals with the physiological optics of the eye as well. Some of his discoveries and experiments are taken from these two books: determination of the radius of curvature of the cornea, discovery of the nasal exit of the optic nerve, increase in the radius of curvature of the lens in case of accommodation, Scheiner's procedure (double images with ametropia), refractive indices of various parts of the eye, Scheiner's experiment. Without any doubt, Christoph Scheiner belongs to the foremost scientists of the first half of the 17th century.

  8. 49 CFR 234.217 - Flashing light units.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Flashing light units. 234.217 Section 234.217..., Inspection, and Testing Maintenance Standards § 234.217 Flashing light units. (a) Each flashing light unit.... (b) Each flashing light unit shall be maintained to prevent dust and moisture from entering the...

  9. 49 CFR 234.217 - Flashing light units.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Flashing light units. 234.217 Section 234.217..., Inspection, and Testing Maintenance Standards § 234.217 Flashing light units. (a) Each flashing light unit.... (b) Each flashing light unit shall be maintained to prevent dust and moisture from entering the...

  10. Optical ID Tags for Secure Verification of Multispectral Visible and NIR Signatures

    NASA Astrophysics Data System (ADS)

    Pérez-Cabré, Elisabet; Millán, María S.; Javidi, Bahram

    2008-04-01

    We propose to combine information from visible (VIS) and near infrared (NIR) spectral bands to increase robustness on security systems and deter from unauthorized use of optical tags that permit the identification of a given person or object. The signature that identifies the element under surveillance will be only obtained by the appropriate combination of the visible content and the NIR data. The fully-phase encryption technique is applied to avoid an easy recognition of the resultant signature at the naked eye and an easy reproduction using conventional devices for imaging or scanning. The obtained complex-amplitude encrypted distribution is encoded on an identity (ID) tag. Spatial multiplexing of the encrypted signature allows us to build a distortion-invariant ID tag, so that remote authentication can be achieved even if the tag is captured under rotation or at different distances. We explore the possibility of using partial information of the encrypted distribution. Simulation results are provided and discussed.

  11. Deterministic filtering of breakdown flashing at telecom wavelengths

    NASA Astrophysics Data System (ADS)

    Marini, Loris; Camphausen, Robin; Eggleton, Benjamin J.; Palomba, Stefano

    2017-11-01

    Breakdown flashes are undesired photo-emissions from the active area of single-photon avalanche photo-diodes. They arise from radiative recombinations of hot carriers generated during an avalanche and can induce crosstalk, compromise the measurement of optical quantum states, and hinder the security of quantum communications. Although the spectrum of this emission extends over hundreds of nanometers, active quenching may lead to a smaller uncertainty in the time of emission, thus enabling deterministic filtering. Our results pave the way to broadband interference mitigation in time-correlated single-photon applications.

  12. Measuring hot flash phenomenonology using ambulatory prospective digital diaries

    PubMed Central

    Fisher, William I.; Thurston, Rebecca C.

    2016-01-01

    Objective This study provides the description, protocol, and results from a novel prospective ambulatory digital hot flash phenomenon diary. Methods This study included 152 midlife women with daily hot flashes who completed an ambulatory electronic hot flash diary continuously for the waking hours of 3 consecutive days. In this diary, women recorded their hot flashes and accompanying characteristics and associations as the hot flashes occurred. Results Self-reported hot flash severity on the digital diaries indicated that the majority of hot flashes were rated as mild (41.3%) or moderate (43.7%). Severe (13.1%) and very severe (1.8%) hot flashes were less common. Hot flash bother ratings were rated as mild (43%), or moderate (33.5%), with fewer hot flashes reported bothersome (17.5%) or very bothersome (6%). The majority of hot flashes were reported as occurring on the on the face (78.9%), neck (74.7%), and chest (61.3%). Prickly skin was reported concurrently with 32% of hot flashes, 7% with anxiety and 5% with nausea. A novel finding, 38% of hot flashes were accompanied by a premonitory aura. Conclusion A prospective electronic digital hot flash diary allows for a more precise quantitation of hot flashes while overcoming many of the limitations of commonly employed retrospective questionnaires and paper diaries. Unique insights into the phenomenology, loci and associated characteristics of hot flashes were obtained using this device. The digital hot flash phenomenology diary is recommended for future ambulatory studies of hot flashes as a prospective measure of the hot flash experience. PMID:27404030

  13. Measuring hot flash phenomenonology using ambulatory prospective digital diaries.

    PubMed

    Fisher, William I; Thurston, Rebecca C

    2016-11-01

    This study provides the description, protocol, and results from a novel prospective ambulatory digital hot flash phenomenon diary. This study included 152 midlife women with daily hot flashes who completed an ambulatory electronic hot flash diary continuously for the waking hours of three consecutive days. In this diary, women recorded their hot flashes and accompanying characteristics and associations as the hot flashes occurred. Self-reported hot flash severity on the digital diaries indicated that the majority of hot flashes were rated as mild (41.3%) or moderate (43.7%). Severe (13.1%) and very severe (1.8%) hot flashes were less common. Hot flash bother ratings were rated as mild (43%), or moderate (33.5%), with fewer hot flashes reported bothersome (17.5%) or very bothersome (6%). The majority of hot flashes were reported as occurring on the face (78.9%), neck (74.7%), and chest (61.3%). Of all reported hot flashes, 32% occurred concurrently with prickly skin, 7% with anxiety, and 5% with nausea. A novel finding from the study was that 38% of hot flashes were accompanied by a premonitory aura. A prospective electronic digital hot flash diary allows for a more precise quantitation of hot flashes while overcoming many of the limitations of commonly used retrospective questionnaires and paper diaries. Unique insights into the phenomenology, loci, and associated characteristics of hot flashes were obtained using this device. The digital hot flash phenomenology diary is recommended for future ambulatory studies of hot flashes as a prospective measure of the hot flash experience.

  14. Analysis of Fundus Shape in Highly Myopic Eyes by Using Curvature Maps Constructed from Optical Coherence Tomography

    PubMed Central

    Miyake, Masahiro; Yamashiro, Kenji; Akagi-Kurashige, Yumiko; Oishi, Akio; Tsujikawa, Akitaka; Hangai, Masanori; Yoshimura, Nagahisa

    2014-01-01

    Purpose To evaluate fundus shape in highly myopic eyes using color maps created through optical coherence tomography (OCT) image analysis. Methods We retrospectively evaluated 182 highly myopic eyes from 113 patients. After obtaining 12 lines of 9-mm radial OCT scans with the fovea at the center, the Bruch’s membrane line was plotted and its curvature was measured at 1-µm intervals in each image, which was reflected as a color topography map. For the quantitative analysis of the eye shape, mean absolute curvature and variance of curvature were calculated. Results The color maps allowed staphyloma visualization as a ring of green color at the edge and as that of orange-red color at the bottom. Analyses of mean and variance of curvature revealed that eyes with myopic choroidal neovascularization tended to have relatively flat posterior poles with smooth surfaces, while eyes with chorioretinal atrophy exhibited a steep, curved shape with an undulated surface (P<0.001). Furthermore, eyes with staphylomas and those without clearly differed in terms of mean curvature and the variance of curvature: 98.4% of eyes with staphylomas had mean curvature ≥7.8×10−5 [1/µm] and variance of curvature ≥0.26×10−8 [1/µm]. Conclusions We established a novel method to analyze posterior pole shape by using OCT images to construct curvature maps. Our quantitative analysis revealed that fundus shape is associated with myopic complications. These values were also effective in distinguishing eyes with staphylomas from those without. This tool for the quantitative evaluation of eye shape should facilitate future research of myopic complications. PMID:25259853

  15. [Clinical feature of chronic compressive optic neuropathy without optic atrophy].

    PubMed

    Jiang, Libin; Shi, Jitong; Liu, Wendong; Kang, Jun; Wang, Ningli

    2014-12-01

    To investigate the clinical feature of the chronic compressive optic neuropathy without optic atrophy. Retrospective cases series study. The clinical data of 25 patients (37 eyes) with chronic compressive optic neuropathy without optic atrophy, treated in Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, from October, 2005 to March, 2014, were collected. Those patients had been showing visual symptoms for 6 months or longer, but missed diagnosed or misdiagnosed as other eye diseases due to their normal or slightly changed fundi. The collected data including visual acuities, visual fields, neuroimaging and/or pathologic diagnosis were analyzed. Among the 25 patients, there were 5 males and 20 females, and their ages range from 9 to 74 years [average (47.5 ± 13.4) years]. All patients suffered progressive impaired vision in single eye or both eyes, without exophthalmos or abnormal eye movements. Except one patient had a headache, other patients did not show systemic symptoms. The corrected visual acuities were between HM to 1.0, and their appearances of optic discs and colors of fundi were normal. After neuroimaging and/or pathological examination, it was proven that 14 patients suffered tuberculum sellae meningiomas, 5 patients with hypophysoma, 3 patient with optic nerve sheath meningioma in orbital apex, 1 patient with cavernous hemangioma, 1 patient with vascular malformation in orbital apex and 1 patient with optic nerve glioma. Among the 19 patients whose suffered occupied lesions of saddle area, 14 patients underwent visual field examinations, and only 4 patients showed classic visual field defects caused by optic chiasmal lesions. Occult progressive visual loss was the most important clinical feature of the disease.

  16. Optical properties of honeycomb photonic structures

    NASA Astrophysics Data System (ADS)

    Sinelnik, Artem D.; Rybin, Mikhail V.; Lukashenko, Stanislav Y.; Limonov, Mikhail F.; Samusev, Kirill B.

    2017-06-01

    We study, theoretically and experimentally, optical properties of different types of honeycomb photonic structures, known also as "photonic graphene." First, we employ the two-photon polymerization method to fabricate the honeycomb structures. In the experiment, we observe a strong diffraction from a finite number of elements, thus providing a unique tool to define the exact number of scattering elements in the structure with the naked eye. Next, we study theoretically the transmission spectra of both honeycomb single layer and two-dimensional (2D) structures of parallel dielectric circular rods. When the dielectric constant of the rod materials ɛ is increasing, we reveal that a 2D photonic graphene structure transforms into a metamaterial when the lowest TE 01 Mie gap opens up below the lowest Bragg band gap. We also observe two Dirac points in the band structure of 2D photonic graphene at the K point of the Brillouin zone and demonstrate a manifestation of Dirac lensing for the TM polarization. The performance of the Dirac lens is that the 2D photonic graphene layer converts a wave from point source into a beam with flat phase surfaces at the Dirac frequency for the TM polarization.

  17. The Advanced Human Eye Model (AHEM): a personal binocular eye modeling system inclusive of refraction, diffraction, and scatter.

    PubMed

    Donnelly, William

    2008-11-01

    To present a commercially available software tool for creating eye models to assist the development of ophthalmic optics and instrumentation, simulate ailments or surgery-induced changes, explore vision research questions, and provide assistance to clinicians in planning treatment or analyzing clinical outcomes. A commercially available eye modeling system was developed, the Advanced Human Eye Model (AHEM). Two mainstream optical software engines, ZEMAX (ZEMAX Development Corp) and ASAP (Breault Research Organization), were used to construct a similar software eye model and compared. The method of using the AHEM is described and various eye modeling scenarios are created. These scenarios consist of retinal imaging of targets and sources; optimization capability; spectacles, contact lens, and intraocular lens insertion and correction; Zernike surface deformation on the cornea; cataract simulation and scattering; a gradient index lens; a binocular mode; a retinal implant; system import/export; and ray path exploration. Similarity of the two different optical software engines showed validity to the mechanism of the AHEM. Metrics and graphical data are generated from the various modeling scenarios particular to their input specifications. The AHEM is a user-friendly commercially available software tool from Breault Research Organization, which can assist the design of ophthalmic optics and instrumentation, simulate ailments or refractive surgery-induced changes, answer vision research questions, or assist clinicians in planning treatment or analyzing clinical outcomes.

  18. New Observational Evidence of Flash Mixing on the White Dwarf Cooling Curve

    NASA Technical Reports Server (NTRS)

    Brown, T. M.; Lanz, T.; Sweigart, A. V.; Cracraft, Misty; Hubeny, Ivan; Landsman, W. B.

    2011-01-01

    Blue hook stars are a class of subluminous extreme horizontal branch stars that were discovered in UV images of the massive globular clusters w Cen and NGC 2808. These stars occupy a region of the HR diagram that is unexplained by canonical stellar evolution theory. Using new theoretical evolutionary and atmospheric models, we have shown that the blue hook stars are very likely the progeny of stars that undergo extensive internal mixing during a late helium-core flash on the white dwarf cooling curve. This "flash mixing" produces hotter-than-normal EHB stars with atmospheres significantly enhanced in helium and carbon. The larger bolometric correction, combined with the decrease in hydrogen opacity, makes these stars appear sub luminous in the optical and UV. Flash mixing is more likely to occur in stars born with a high helium abundance, due to their lower mass at the main sequence turnoff. For this reason, the phenomenon is more common in those massive globular clusters that show evidence for secondary populations enhanced in helium. However, a high helium abundance does not, by itself, explain the presence of blue hook stars in massive globular clusters. Here, we present new observational evidence for flash mixing, using recent HST observations. These include UV color-magnitude diagrams of six massive globular clusters and far-UV spectroscopy of hot subdwarfs in one of these clusters (NGC 2808).

  19. Biologically inspired artificial compound eyes.

    PubMed

    Jeong, Ki-Hun; Kim, Jaeyoun; Lee, Luke P

    2006-04-28

    This work presents the fabrication of biologically inspired artificial compound eyes. The artificial ommatidium, like that of an insect's compound eyes, consists of a refractive polymer microlens, a light-guiding polymer cone, and a self-aligned waveguide to collect light with a small angular acceptance. The ommatidia are omnidirectionally arranged along a hemispherical polymer dome such that they provide a wide field of view similar to that of a natural compound eye. The spherical configuration of the microlenses is accomplished by reconfigurable microtemplating, that is, polymer replication using the deformed elastomer membrane with microlens patterns. The formation of polymer waveguides self-aligned with microlenses is also realized by a self-writing process in a photosensitive polymer resin. The angular acceptance is directly measured by three-dimensional optical sectioning with a confocal microscope, and the detailed optical characteristics are studied in comparison with a natural compound eye.

  20. Subretinal fluid in eyes with active ocular toxoplasmosis observed using spectral domain optical coherence tomography.

    PubMed

    Ouyang, Yanling; Li, Fuqiang; Shao, Qing; Heussen, Florian M; Keane, Pearse A; Stübiger, Nicole; Sadda, Srinivas R; Pleyer, Uwe

    2015-01-01

    To describe the clinical finding of subretinal fluid (SRF) in the posterior pole by spectral domain optical coherence tomography (SD-OCT) in eyes with active ocular toxoplasmosis (OT). Retrospective case series. Thirty-nine eyes from 38 patients with active OT [corrected].. Eyes with active OT which underwent SD-OCT were reviewed. SRFs in the posterior pole were further analyzed. Presence of SRF; its accompanying features, e.g. retinal necrosis, cystoid macular edema (CME), choroidal neovascularization (CNV); and longitudinal changes of SRF, including maximum height and total volume before and after treatment. SRF presented in 45.5% (or 15/33) of eyes with typical active OT and in 51.3% (or 20/39) of eyes with active OT. The mean maximum height and total volume of SRF were 161.0 (range: 23-478) µm and 0.47 (range: 0.005-4.12) mm3, respectively. For 12 eyes with SRF related to active retinal necrosis, SRF was observed with complete absorption after conventional anti-toxoplasmosis treatment. The mean duration for observation of SRF clearance was 33.8 (range: 7-84) days. The mean rate of SRF clearance was 0.0128 (range: 0.0002-0.0665) mm3/day. SRF (i.e., serous retinal detachment) is a common feature in patients with active OT when SD-OCT is performed. The majority of SRF was associated with retinal necrosis and reacted well to conventional therapy, regardless of total fluid volume. However, SRF accompanying with CME or CNV responded less favorably or remained refractory to conventional or combined intravitreal treatment, even when the SRF was small in size.

  1. Optic nerve head cupping in glaucomatous and non-glaucomatous optic neuropathy.

    PubMed

    Fard, Masoud Aghsaei; Moghimi, Sasan; Sahraian, Alireza; Ritch, Robert

    2018-05-23

    Enlargement of optic disc cupping is seen both in glaucoma and in neurological disorders. We used enhanced depth imaging with spectral-domain optical coherence tomography to differentiate glaucoma from non-glaucomatous optic neuropathy. The optic discs were scanned in this prospective comparative study, and the lamina cribrosa (LC) thickness and anterior laminar depth (ALD) in the central, superior and inferior optic nerve head, and peripapillary choroidal thicknesses, were measured. There were 31 eyes of 31 patients with severe glaucoma and 33 eyes of 19 patients with non-glaucomatous cupping. Eyes of 29 healthy controls were also enrolled. There was no significant difference in the cup-to-disc ratio and in the average peripapillary nerve fibre layer thickness between the glaucoma and non-glaucomatous cupping groups (p>0.99). The average peripapillary choroidal thickness was thinner in glaucoma eyes than in the control eyes after adjusting for age and axial length. Glaucomatous and non-glaucomatous eyes had greater ALD and thinner LC than the control eyes (p<0.001 for both). ALDs of glaucoma eyes were deeper than non-glaucomatous eyes (p=0.01 for central ALD) when age, axial length and peripapillary choroidal thickness were included in the linear mixed model. Prelaminar thickness and LC thickness of glaucoma eyes were not different from non-glaucomatous eyes after adjusting. Deeper ALD was observed in glaucoma than non-glaucomatous cupping after adjusting for choroidal thickness. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Cortexin diffusion in human eye sclera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Genina, Elina A; Bashkatov, A N; Tuchin, Valerii V

    2011-05-31

    Investigation of the diffusion of cytamines, a typical representative of which is cortexin, is important for evaluating the drug dose, necessary to provide sufficient concentration of the preparation in the inner tissues of the eye. In the present paper, the cortexin diffusion rate in the eye sclera is measured using the methods of optical coherence tomography (OCT) and reflectance spectroscopy. The technique for determining the diffusion coefficient is based on the registration of temporal dependence of the eye sclera scattering parameters caused by partial replacement of interstitial fluid with the aqueous cortexin solution, which reduces the level of the OCTmore » signal and decreases the reflectance of the sclera. The values of the cortexin diffusion coefficient obtained using two independent optical methods are in good agreement. (optical technologies in biophysics and medicine)« less

  3. Four Cases of Spontaneous Neoplasia in the Naked Mole-Rat (Heterocephalus glaber), A Putative Cancer-Resistant Species.

    PubMed

    Taylor, Kyle R; Milone, Nicholas A; Rodriguez, Carlos E

    2017-01-01

    The naked mole-rat (Heterocephalus glaber) is widely acclaimed to be cancer-resistant and of considerable research interest based on a paucity of reports of neoplasia in this species. We have, however, encountered four spontaneous cases of neoplasia and one presumptive case of neoplasia through routine necropsy and biopsy of individuals in a zoo collection of nonhybrid naked mole-rats bred from a single pair. One case each of metastasizing hepatocellular carcinoma, nephroblastoma (Wilms' tumor), and multicentric lymphosarcoma, as well as presumptive esophageal adenocarcinoma (Barrett's esophagus-like) was identified postmortem among 37 nonautolyzed necropsy submissions of naked mole-rats over 1-year-old that were submitted for necropsy between 1998 and August 2015. One incidental case of cutaneous hemangioma was also identified antemortem by skin biopsy from one naked mole-rat examined for trauma. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Diagnostic Accuracy of Optical Coherence Tomography and Scanning Laser Tomography for Identifying Glaucoma in Myopic Eyes.

    PubMed

    Malik, Rizwan; Belliveau, Anne C; Sharpe, Glen P; Shuba, Lesya M; Chauhan, Balwantray C; Nicolela, Marcelo T

    2016-06-01

    Ruling out glaucoma in myopic eyes often poses a diagnostic challenge because of atypical optic disc morphology and visual field defects that can mimic glaucoma. We determined whether neuroretinal rim assessment based on Bruch's membrane opening (BMO), rather than conventional optic disc margin (DM)-based assessment or retinal nerve fiber layer (RNFL) thickness, yielded higher diagnostic accuracy in myopic patients with glaucoma. Case-control, cross-sectional study. Myopic patients with glaucoma (n = 56) and myopic normal controls (n = 74). Myopic subjects with refraction error greater than -2 diopters (D) (spherical equivalent) and typical myopic optic disc morphology, with and without glaucoma, were recruited from a glaucoma clinic and a local optometry practice. The final classification of myopic glaucoma or myopic control was based on consensus assessment by 3 clinicians of visual fields and optic disc photographs. Participants underwent imaging with confocal scanning laser tomography for measurement of DM rim area (DM-RA) and with spectral domain optical coherence tomography (SD OCT) for quantification of a BMO-based neuroretinal rim parameter, minimum rim width (BMO-MRW), and RNFL thickness. Sensitivity of DM-RA, BMO-MRW, and RNFL thickness at a fixed specificity of 90% and partial area under the curves (pAUCs) for global and sectoral parameters for specificities ≥90%. Sensitivities at 90% specificity were 30% for DM-RA and 71% for both BMO-MRW and RNFL thickness. The pAUC was higher for the BMO-MRW compared with DM-RA (P < 0.001), but similar to RNFL thickness (P > 0.5). Sectoral values of BMO-MRW tended to have a higher, but nonsignificant, pAUC across all sectors compared with RNFL thickness. Bruch's membrane opening MRW is more sensitive than DM-RA and similar to RNFL thickness for the identification of glaucoma in myopic eyes and offers a valuable diagnostic tool for patients with glaucoma with myopic optic discs. Copyright © 2016 American Academy

  5. Emmetropization and Eye Growth in Young Aphakic Chickens

    PubMed Central

    Ai, Likun; Li, Jing; Guan, Huan; Wildsoet, Christine F.

    2009-01-01

    Purpose To establish a chick model to investigate the trends of eye growth and emmetropization after early lensectomy for congenital cataract. Methods Four monocular treatments were applied: lens extraction (LX); sham surgery/-30 D lens; LX/+20 D lens; and LX/+30-D lens (nine per group). Lens powers were selected to slightly undercorrect or overcorrect the induced hyperopia in LX eyes and to induce comparable hyperopia in sham-surgery eyes. Refractive errors and axial ocular dimensions were measured over a 28-day period. External ocular dimensions were obtained when the eyes were enucleated on the last day. Results The growth patterns of experimental (Exp) eyes varied with the type of manipulation. All eyes experiencing hyperopia initially grew more than their fellow eyes and exhibited myopic shifts in refraction. The sham/-30 D lens group showed the greatest increase in optical axial length, followed by the LX group, and then the LX/+20 D lens group. The Exp eyes of the LX/+30 D lens group, which were initially slightly myopic, grew least, and showed a small hyperopic shift. Lensectomized eyes enlarged more equatorially than axially (i.e., oblate), irrespective of the optical treatment applied. Conclusions The refractive changes observed in young, aphakic eyes are consistent with compensation for the defocus experienced, and thus emmetropization. However, differences in the effects of lensectomy compared to those of sham surgery raise the possibility that the lens is a source of essential growth factors. Alterative optical and mechanical explanations are offered for the oblate shapes of aphakic eyes. PMID:18719085

  6. Electronic Flash In Data Acquisition

    NASA Astrophysics Data System (ADS)

    Miller, C. E.

    1982-02-01

    Photographic acquisition of data often may be simplified, or the data quality improved upon by employing electronic flash sources with traditional equipment or techniques. The relatively short flash duration compared to movie camera shutters, or to the long integration time of video camera provides improved spatial resolution through blur reduction, particularly important as image movement becomes a significant fraction of film format dimension. Greater accuracy typically is achieved in velocity and acceleration determinations by using a stroboscopic light source rather than a movie camera frame-rate control as a time standard. Electrical efficiency often is an important advantage of electronic flash sources since almost any necessary light level for exposure may be produced, yet the source typically is "off" most of the time. Various synchronization techniques greatly expand the precise control of exposure. Biomechanical and sports equipment studies may involve velocities up to 200 feet-per-second, and often will have associated very rapid actions of interest. The need for brief exposures increases H.s one "ZOOMS in on the action." In golf, for example, the swing may be examined using 100 microsecond (Us) flashes at rates of 60 or 120 flashes-per-second (FPS). Accurate determination of linear and rotational velocity of the ball requires 10 Us flashes at 500-1,000 FPS, while sub-Us flashes at 20,000-50,000 FPS are required to resolve the interaction of the ball and the club, head. Some seldom. used techniques involving streak photography are described, with enhanced results obtained by combining strobe with the usual continuous light source. The combination of strobe and a fast electro-mechanical shutter is considered for Us photography under daylight conditions.

  7. In vivo photothermal optical coherence tomography of gold nanorods in the mouse eye (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Lapierre-Landry, Maryse; Gordon, Andrew Y.; Penn, John S.; Skala, Melissa C.

    2017-02-01

    Optical coherence tomography (OCT) has become standard in retinal imaging at the pre-clinical and clinical level by allowing non-invasive, three-dimensional imaging of the tissue structure. However, OCT lacks specificity to contrast agents that could be used for in vivo molecular imaging. We have performed in vivo photothermal optical coherence tomography (PT-OCT) of targeted gold nanorods in the mouse retina after the mice were injected systemically with the contrast agent. To our knowledge, we are the first to perform PT-OCT in the eye and image targeted gold nanorods with this technology. As a model of age-related wet macular degeneration, lesions were induced by laser photocoagulation in each mouse retina (n=12 eyes). Untargeted and targeted (anti-mouse CD102 antibody, labeling neovasculature) gold nanorods (peak absorption λ=750nm) were injected intravenously by tail-vein injection five days after lesion induction, and imaged the same day with PT-OCT. Our instrument is a spectral domain OCT system (λ=860nm) with a Titanium:Sapphire laser (λ=750nm) added to the beam path using a 50:50 coupler to heat the gold nanorods. We acquired PT-OCT volumes of one lesion per mouse eye. There was a significant increase in photothermal intensity per unit area of the lesion in the targeted gold nanorods group versus the saline control group and the untargeted gold nanorods group. This experiment demonstrates the feasibility of PT-OCT to image the distribution of molecular contrast agents in the mouse retina, including in highly scattering lesions. In the future we will use this method to identify new biomarkers linked with retinal disease.

  8. A comparison of techniques to assess cervicovaginal irritation and evaluation of the variability between two observers.

    PubMed

    Ballagh, Susan A; Mauck, Christine K; Henry, Deborah; Archer, David F; Abercrombie, Theresa; Callahan, Marianne M; Gabelnick, Henry L

    2004-09-01

    Colposcopy is used to evaluate effects of new vaginal products on cervicovaginal epithelium as part of the US Food and Drug Administration-mandated product approval process, yet few aspects of its use have been investigated. To determine the effect of the colposcopic examination itself on the number and type of findings seen, to compare colposcopy with the AviScope hand-held device and the naked eye and to compare the findings reported by two examiners during a single visit. Fourteen healthy women volunteered for five paired examinations in random order: (1) naked eye inspection plus colposcopy done twice by a single examiner; (2) naked eye inspection plus AviScope examination, then naked eye inspection plus colposcopy by a single examiner; (3) Examination 2 repeated with the order of device reversed; (4) naked eye inspection plus colposcopy done by two examiners; (5) Examination 4 repeated with the order of examiner reversed. The colposcopic examinations were done per published standards but were limited to the areas visible without manipulation of the speculum. Length of colposcopic examination averaged 7 min. The number of colposcopic findings found when the examination was done twice by the same clinician was not statistically different (p = 0.12), suggesting that the examination itself did not induce findings. More findings were seen using magnification than naked eye. A similar number of findings were seen by AviScope compared to the colposcope (p = 0.99), but clinically significant findings were "undercalled" or "overcalled" by the AviScope. A weighted kappa score of the "worst" colposcopic finding was 0.32 (SE 0.10, p = 0.00), indicating moderate agreement between examiners. The colposcopic examination is not burdensome nor does it induce findings. If naked eye observation were used alone in practice, these data suggest that half the colposcopically detected findings would be missed. Using the naked eye observation for screening would minimally reduce the

  9. Herpes Zoster Optic Neuropathy.

    PubMed

    Kaufman, Aaron R; Myers, Eileen M; Moster, Mark L; Stanley, Jordan; Kline, Lanning B; Golnik, Karl C

    2018-06-01

    Herpes zoster optic neuropathy (HZON) is a rare manifestation of herpes zoster ophthalmicus (HZO). The aim of our study was to better characterize the clinical features, therapeutic choices, and visual outcomes in HZON. A retrospective chart review was performed at multiple academic eye centers with the inclusion criteria of all eyes presenting with optic neuropathy within 1 month of cutaneous zoster of the ipsilateral trigeminal dermatome. Data were collected regarding presenting features, treatment regimen, and visual acuity outcomes. Six patients meeting the HZON inclusion criteria were identified. Mean follow-up was 2.75 months (range 0.5-4 months). Herpes zoster optic neuropathy developed at a mean of 14.1 days after initial rash (range 6-30 days). Optic neuropathy was anterior in 2 eyes and retrobulbar in 4 eyes. Other manifestations of HZO included keratoconjunctivitis (3 eyes) and iritis (4 eyes). All patients were treated with systemic antiviral therapy in addition to topical and/or systemic corticosteroids. At the last follow-up, visual acuity in 3 eyes had improved relative to presentation, 2 eyes had worsened, and 1 eye remained the same. The 2 eyes that did not receive systemic corticosteroids had the best observed final visual acuity. Herpes zoster optic neuropathy is an unusual but distinctive complication of HZO. Visual recovery after HZON is variable. Identification of an optimal treatment regiment for HZON could not be identified from our patient cohort. Systemic antiviral agents are a component of HZON treatment regimens. Efficacy of systemic corticosteroids for HZON remains unclear and should be considered on a case-by-case basis.

  10. Novel shadowless imaging for eyes-like diagnosis in vivo

    NASA Astrophysics Data System (ADS)

    Xue, Ning; Jiang, Kai; Li, Qi; Zhang, Lili; Ma, Li; Huang, Guoliang

    2016-10-01

    Eyes-like diagnosis was a traditional Chinese medicine method for many diseases, such as chronic gastritis, diabetes, hypertension etc. There was a close relationship between viscera and eyes-like. White-Eye was divided into fourteen sections, which corresponded to different viscera, so eyes-like was the reflection of status of viscera, in another words, it was an epitome of viscera health condition. In this paper, we developed a novel shadowless imaging technology and system for eyes-like diagnosis in vivo, which consisted of an optical shadowless imaging device for capturing and saving images of patients' eyes-like, and a computer linked to the device for image processing. A character matching algorithm was developed to extract the character of white-eye in corresponding sections of eyes-like images taken by the optical shadowless imaging device, according to the character of eyes-like, whether there were viscera diseases could be learned. A series of assays were carried out, and the results verified the feasibility of eyes-like diagnosis technique.

  11. Technology of uncooled fast polycrystalline PbSe focal plane arrays in systems for muzzle flash detection

    NASA Astrophysics Data System (ADS)

    Kastek, Mariusz; PiÄ tkowski, Tadeusz; Polakowski, Henryk; Barela, Jaroslaw; Firmanty, Krzysztof; Trzaskawka, Piotr; Vergara, German; Linares, Rodrigo; Gutierrez, Raul; Fernandez, Carlos; Montojo Supervielle, Maria Teresa

    2014-05-01

    The paper presents some aspects of muzzle flash detection using low resolution polycrystalline PbSe 32×32 and 80×80 detectors FPA operating at room temperature (uncooled performance). These sensors, which detect in MWIR (3 - 5 microns region) and are manufactured using proprietary technology from New Infrared Technologies (VPD PbSe - Vapor Phase Deposition of polycrystalline PbSe), can be applied to muzzle flash detection. The system based in the uncooled 80×80 FPA monolithically integrated with the CMOS readout circuitry has allowed image recording with frame rates over 2000 Hz (true snapshot acquisition), whereas the lower density, uncooled 32×32 FPA is suitable for being used in low cost infrared imagers sensitive in the MWIR band with frame rates above 1000 Hz. The FPA detector, read-out electronics and processing electronics (allows the implementation of some algorithms for muzzle flash detection) of both systems are presented. The systems have been tested at field test ground. Results of detection range measurement with two types of optical systems (wide and narrow field of view) have been shown. The theoretical analysis of possibility detection of muzzle flash and initial results of testing of some algorithms for muzzle flash detection have been presented too.

  12. Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch.

    PubMed

    Ruggeri, Marco; Uhlhorn, Stephen R; De Freitas, Carolina; Ho, Arthur; Manns, Fabrice; Parel, Jean-Marie

    2012-07-01

    An optical switch was implemented in the reference arm of an extended depth SD-OCT system to sequentially acquire OCT images at different depths into the eye ranging from the cornea to the retina. A custom-made accommodation module was coupled with the delivery of the OCT system to provide controlled step stimuli of accommodation and disaccommodation that preserve ocular alignment. The changes in the lens shape were imaged and ocular distances were dynamically measured during accommodation and disaccommodation. The system is capable of dynamic in vivo imaging of the entire anterior segment and eye-length measurement during accommodation in real-time.

  13. A Model of the Human Eye

    ERIC Educational Resources Information Center

    Colicchia, G.; Wiesner, H.; Waltner, C.; Zollman, D.

    2008-01-01

    We describe a model of the human eye that incorporates a variable converging lens. The model can be easily constructed by students with low-cost materials. It shows in a comprehensible way the functionality of the eye's optical system. Images of near and far objects can be focused. Also, the defects of near and farsighted eyes can be demonstrated.

  14. A Comparison of Lightning Flashes as Observed by the Lightning Imaging Sensor and the North Alabama Lightning Mapping Array

    NASA Technical Reports Server (NTRS)

    Bateman, M. G.; Mach, D. M.; McCaul, M. G.; Bailey, J. C.; Christian, H. J.

    2008-01-01

    The Lightning Imaging Sensor (LIS) aboard the TRMM satellite has been collecting optical lightning data since November 1997. A Lightning Mapping Array (LMA) that senses VHF impulses from lightning was installed in North Alabama in the Fall of 2001. A dataset has been compiled to compare data from both instruments for all times when the LIS was passing over the domain of our LMA. We have algorithms for both instruments to group pixels or point sources into lightning flashes. This study presents the comparison statistics of the flash data output (flash duration, size, and amplitude) from both algorithms. We will present the results of this comparison study and show "point-level" data to explain the differences. AS we head closer to realizing a Global Lightning Mapper (GLM) on GOES-R, better understanding and ground truth of each of these instruments and their respective flash algorithms is needed.

  15. Two visual observations of relevance to the search for optical counterparts of gamma-ray sources

    NASA Astrophysics Data System (ADS)

    Warner, B.

    1986-05-01

    The authors draw attention to a visual observation of a brief flash from ζ Lyrae, observed by Heis in 1850, which resembles the optical burst detected electronically by Wdowiak and Clifton (1985) from β Cam in 1969. Visual observation by the author of a second magnitude flash of very short duration is shown to originate from planar reflection from a very distant satellite. Such flashes will contribute to the "noise" in all-sky searches for optical counterparts of γ-ray bursters.

  16. Scleral birefringence as measured by polarization-sensitive optical coherence tomography and ocular biometric parameters of human eyes in vivo.

    PubMed

    Yamanari, Masahiro; Nagase, Satoko; Fukuda, Shinichi; Ishii, Kotaro; Tanaka, Ryosuke; Yasui, Takeshi; Oshika, Tetsuro; Miura, Masahiro; Yasuno, Yoshiaki

    2014-05-01

    The relationship between scleral birefringence and biometric parameters of human eyes in vivo is investigated. Scleral birefringence near the limbus of 21 healthy human eyes was measured using polarization-sensitive optical coherence tomography. Spherical equivalent refractive error, axial eye length, and intraocular pressure (IOP) were measured in all subjects. IOP and scleral birefringence of human eyes in vivo was found to have statistically significant correlations (r = -0.63, P = 0.002). The slope of linear regression was -2.4 × 10(-2) deg/μm/mmHg. Neither spherical equivalent refractive error nor axial eye length had significant correlations with scleral birefringence. To evaluate the direct influence of IOP to scleral birefringence, scleral birefringence of 16 ex vivo porcine eyes was measured under controlled IOP of 5-60 mmHg. In these ex vivo porcine eyes, the mean linear regression slope between controlled IOP and scleral birefringence was -9.9 × 10(-4) deg/μm/mmHg. In addition, porcine scleral collagen fibers were observed with second-harmonic-generation (SHG) microscopy. SHG images of porcine sclera, measured on the external surface at the superior side to the cornea, showed highly aligned collagen fibers parallel to the limbus. In conclusion, scleral birefringence of healthy human eyes was correlated with IOP, indicating that the ultrastructure of scleral collagen was correlated with IOP. It remains to show whether scleral collagen ultrastructure of human eyes is affected by IOP as a long-term effect.

  17. Depth-estimation-enabled compound eyes

    NASA Astrophysics Data System (ADS)

    Lee, Woong-Bi; Lee, Heung-No

    2018-04-01

    Most animals that have compound eyes determine object distances by using monocular cues, especially motion parallax. In artificial compound eye imaging systems inspired by natural compound eyes, object depths are typically estimated by measuring optic flow; however, this requires mechanical movement of the compound eyes or additional acquisition time. In this paper, we propose a method for estimating object depths in a monocular compound eye imaging system based on the computational compound eye (COMPU-EYE) framework. In the COMPU-EYE system, acceptance angles are considerably larger than interommatidial angles, causing overlap between the ommatidial receptive fields. In the proposed depth estimation technique, the disparities between these receptive fields are used to determine object distances. We demonstrate that the proposed depth estimation technique can estimate the distances of multiple objects.

  18. The “Naked Coral” Hypothesis Revisited – Evidence for and Against Scleractinian Monophyly

    PubMed Central

    Forêt, Sylvain; Huttley, Gavin; Miller, David J.; Chen, Chaolun Allen

    2014-01-01

    The relationship between Scleractinia and Corallimorpharia, Orders within Anthozoa distinguished by the presence of an aragonite skeleton in the former, is controversial. Although classically considered distinct groups, some phylogenetic analyses have placed the Corallimorpharia within a larger Scleractinia/Corallimorpharia clade, leading to the suggestion that the Corallimorpharia are “naked corals” that arose via skeleton loss during the Cretaceous from a Scleractinian ancestor. Scleractinian paraphyly is, however, contradicted by a number of recent phylogenetic studies based on mt nucleotide (nt) sequence data. Whereas the “naked coral” hypothesis was based on analysis of the sequences of proteins encoded by a relatively small number of mt genomes, here a much-expanded dataset was used to reinvestigate hexacorallian phylogeny. The initial observation was that, whereas analyses based on nt data support scleractinian monophyly, those based on amino acid (aa) data support the “naked coral” hypothesis, irrespective of the method and with very strong support. To better understand the bases of these contrasting results, the effects of systematic errors were examined. Compared to other hexacorallians, the mt genomes of “Robust” corals have a higher (A+T) content, codon usage is far more constrained, and the proteins that they encode have a markedly higher phenylalanine content, leading us to suggest that mt DNA repair may be impaired in this lineage. Thus the “naked coral” topology could be caused by high levels of saturation in these mitochondrial sequences, long-branch effects or model violations. The equivocal results of these extensive analyses highlight the fundamental problems of basing coral phylogeny on mitochondrial sequence data. PMID:24740380

  19. E2F4 is required for early eye patterning.

    PubMed

    Ruzhynsky, Vladimir A; Furimsky, Marosh; Park, David S; Wallace, Valerie A; Slack, Ruth S

    2009-01-01

    Increasingly, studies reveal novel functions for cell cycle proteins during development. Here, we investigated the role of E2F4 in eye development. E2F4-deficient mouse embryos exhibit severe early eye patterning defects, which are evident from embryonic day 11.5 and characterized by aberrant shape of the optic cup, coloboma as well as abnormal eye pigmentation. Loss of E2F4 is associated with proximal-distal patterning defects in the optic vesicle. These defects are characterized by the expansion of optic stalk marker gene expression to the optic cup and reduced expression of ventral optic cup markers. These defects are associated with a split of Shh expression domain at the ventral midline of the forebrain and expansion of the Shh activity into the ventral optic cup. Despite these patterning defects, early neuronal differentiation and Shh expression in the retina are not affected by E2F4 deletion. Overall, the results of our studies show a novel role of E2F4 in the early eye development. 2009 S. Karger AG, Basel.

  20. Registration of a tufted-naked seed upland cotton germplasm

    USDA-ARS?s Scientific Manuscript database

    A tufted-naked cotton (Gossypium hirsutum L.) mutant, 9023n4t (Reg. No. GP-971, PI 667553) was developed from the cultivar SC 9023 (9023) (PI 590933) through chemical mutagenesis. Germplasm line 9023n4t was developed by the Department of Plant and Soil Science, Texas Tech University, and released in...

  1. Changes in Tear Volume after 3% Diquafosol Treatment in Patients with Dry Eye Syndrome: An Anterior Segment Spectral-domain Optical Coherence Tomography Study.

    PubMed

    Lee, Kwan Bok; Koh, Kyung Min; Kwon, Young A; Song, Sang Wroul; Kim, Byoung Yeop; Chung, Jae Lim

    2017-08-01

    To evaluate changes in the tear meniscus area and tear meniscus height over time in patients with dry eye syndrome, using anterior segment spectral-domain optical coherence tomography after the instillation of 3% diquafosol ophthalmic solution. Sixty eyes from 30 patients with mild to moderate dry eye syndrome were included. Tear meniscus images acquired by anterior segment spectral-domain optical coherence tomography were analyzed using National Institutes of Health's image-analysis software (ImageJ 1.44p). Tear meniscus area and tear meniscus height were measured at baseline, 5 minutes, 10 minutes, and 30 minutes after instillation of a drop of diquafosol in one eye and normal saline in the other eye. Changes in ocular surface disease index score, tear film break-up time, corneal staining score by Oxford schema, and meibomian expressibility were also evaluated at baseline, and after 1 week and 1 month of a diquafosol daily regimen. Sixty eyes from 30 subjects (mean age, 29.3 years; 8 men and 22 women) were included. In eyes receiving diquafosol, tear volume was increased at 5 and 10 minutes compared with baseline. It was also higher than saline instilled eyes at 5, 10, and 30 minutes. Changes in tear volume with respect to baseline were not statistically different after the use of diquafosol for 1 month. Ocular surface disease index score, tear film break-up time, and Oxford cornea stain score were significantly improved after 1 week and 1 month of daily diquafosol instillation, but meibomian expressibility did not change. Topical diquafosol ophthalmic solution effectively increased tear volume for up to 30 minutes, compared to normal saline in patients with dry eye syndrome. © 2017 The Korean Ophthalmological Society

  2. An Analysis of Total Lightning Flash Rates Over Florida

    NASA Astrophysics Data System (ADS)

    Mazzetti, Thomas O.; Fuelberg, Henry E.

    2017-12-01

    Although Florida is known as the "Sunshine State", it also contains the greatest lightning flash densities in the United States. Flash density has received considerable attention in the literature, but lightning flash rate has received much less attention. We use data from the Earth Networks Total Lightning Network (ENTLN) to produce a 5 year (2010-2014) set of statistics regarding total flash rates over Florida and adjacent regions. Instead of tracking individual storms, we superimpose a 0.2° × 0.2° grid over the study region and count both cloud-to-ground (CG) and in-cloud (IC) flashes over 5 min intervals. Results show that the distribution of total flash rates is highly skewed toward small values, whereas the greatest rate is 185 flashes min-1. Greatest average annual flash rates ( 3 flashes min-1) are located near Orlando. The southernmost peninsula, North Florida, and the Florida Panhandle exhibit smaller average annual flash rates ( 1.5 flashes min-1). Large flash rates > 100 flashes min-1 can occur during any season, at any time during the 24 h period, and at any location within the domain. However, they are most likely during the afternoon and early evening in East Central Florida during the spring and summer months.

  3. A global flash flood forecasting system

    NASA Astrophysics Data System (ADS)

    Baugh, Calum; Pappenberger, Florian; Wetterhall, Fredrik; Hewson, Tim; Zsoter, Ervin

    2016-04-01

    The sudden and devastating nature of flash flood events means it is imperative to provide early warnings such as those derived from Numerical Weather Prediction (NWP) forecasts. Currently such systems exist on basin, national and continental scales in Europe, North America and Australia but rely on high resolution NWP forecasts or rainfall-radar nowcasting, neither of which have global coverage. To produce global flash flood forecasts this work investigates the possibility of using forecasts from a global NWP system. In particular we: (i) discuss how global NWP can be used for flash flood forecasting and discuss strengths and weaknesses; (ii) demonstrate how a robust evaluation can be performed given the rarity of the event; (iii) highlight the challenges and opportunities in communicating flash flood uncertainty to decision makers; and (iv) explore future developments which would significantly improve global flash flood forecasting. The proposed forecast system uses ensemble surface runoff forecasts from the ECMWF H-TESSEL land surface scheme. A flash flood index is generated using the ERIC (Enhanced Runoff Index based on Climatology) methodology [Raynaud et al., 2014]. This global methodology is applied to a series of flash floods across southern Europe. Results from the system are compared against warnings produced using the higher resolution COSMO-LEPS limited area model. The global system is evaluated by comparing forecasted warning locations against a flash flood database of media reports created in partnership with floodlist.com. To deal with the lack of objectivity in media reports we carefully assess the suitability of different skill scores and apply spatial uncertainty thresholds to the observations. To communicate the uncertainties of the flash flood system output we experiment with a dynamic region-growing algorithm. This automatically clusters regions of similar return period exceedence probabilities, thus presenting the at-risk areas at a spatial

  4. Quantum Backreaction on Three-Dimensional Black Holes and Naked Singularities.

    PubMed

    Casals, Marc; Fabbri, Alessandro; Martínez, Cristián; Zanelli, Jorge

    2017-03-31

    We analytically investigate backreaction by a quantum scalar field on two rotating Bañados-Teitelboim-Zanelli (BTZ) geometries: that of a black hole and that of a naked singularity. In the former case, we explore the quantum effects on various regions of relevance for a rotating black hole space-time. We find that the quantum effects lead to a growth of both the event horizon and the radius of the ergosphere, and to a reduction of the angular velocity, compared to the unperturbed values. Furthermore, they give rise to the formation of a curvature singularity at the Cauchy horizon and show no evidence of the appearance of a superradiant instability. In the case of a naked singularity, we find that quantum effects lead to the formation of a horizon that shields it, thus supporting evidence for the rôle of quantum mechanics as a cosmic censor in nature.

  5. Ability of Cirrus™ HD-OCT Optic Nerve Head Parameters to Discriminate Normal from Glaucomatous Eyes

    PubMed Central

    Mwanza, Jean-Claude; Oakley, Jonathan D; Budenz, Donald L; Anderson, Douglas R

    2010-01-01

    Purpose To determine the ability of optic nerve head (ONH) parameters measured with spectral domain Cirrus™ HD-OCT to discriminate between normal and glaucomatous eyes and to compare them to the discriminating ability of peripapillary retinal nerve fiber layer (RNFL) thickness measurements performed with Cirrus™ HD-OCT. Design Evaluation of diagnostic test or technology. Participants Seventy-three subjects with glaucoma and one hundred and forty-six age-matched normal subjects. Methods Peripapillary ONH parameters and RNFL thickness were measured in one randomly selected eye of each participant within a 200×200 pixel A-scan acquired with Cirrus™ HD-OCT centered on the ONH. Main Outcome Measures ONH topographic parameters, peripapillary RNFL thickness, and the area under receiver operating characteristic curves (AUCs). Results For distinguishing normal from glaucomatous eyes, regardless of disease stage, the six best parameters (expressed as AUC) were vertical rim thickness (VRT, 0.963), rim area (RA, 0.962), RNFL thickness at clock-hour 7 (0.957), RNFL thickness of the inferior quadrant (0.953), vertical cup-to-disc ratio (VCDR, 0.951) and average RNFL thickness (0.950). The AUC for distinguishing between normal and eyes with mild glaucoma was greatest for RNFL thickness of clock-hour 7 (0.918), VRT (0.914), RA (0.912), RNFL thickness of inferior quadrant (0.895), average RNFL thickness (0.893) and VCDR (0.890). There were no statistically significant differences between AUCs for the best ONH parameters and RNFL thickness measurements (p > 0.05). Conclusions Cirrus™ HD-OCT ONH parameters are able to discriminate between eyes that are normal from those with glaucoma or even mild glaucoma. There is no difference in the ability of ONH parameters and RNFL thickness measurement, as measured with Cirrus™ OCT, to distinguish between normal and glaucomatous eyes. PMID:20920824

  6. Sex-specific but not sexually explicit: pupillary responses to dressed and naked adults.

    PubMed

    Attard-Johnson, Janice; Bindemann, Markus

    2017-05-01

    Dilation of the pupils is an indicator of an observer's sexual interest in other people, but it remains unresolved whether this response is strengthened or diminished by sexually explicit material. To address this question, this study compared pupillary responses of heterosexual men and women to naked and dressed portraits of male and female adult film actors. Pupillary responses corresponded with observers' self-reported sexual orientation, such that dilation occurred during the viewing of opposite-sex people, but were comparable for naked and dressed targets. These findings indicate that pupillary responses provide a sex-specific measure, but are not sensitive to sexually explicit content.

  7. Evaluation of white-to-white distance and anterior chamber depth measurements using the IOL Master, slit-lamp adapted optical coherence tomography and digital photographs in phakic eyes.

    PubMed

    Wilczyński, Michał; Pośpiech-Zabierek, Aleksandra

    2015-01-01

    The accurate measurement of the anterior chamber internal diameter and depth is important in ophthalmic diagnosis and before some eye surgery procedures. The purpose of the study was to compare the white-to-white distance measurements performed using the IOL-Master and photography with internal anterior chamber diameter determined using slit lamp adapted optical coherence tomography in healthy eyes, and to compare anterior chamber depth measurements by IOL-Master and slit lamp adapted optical coherence tomography. The data were gathered prospectively from a non-randomized consecutive series of patients. The examined group consisted of 46 eyes of 39 patients. White-to-white was measured using IOL-Master and photographs of the eye were taken with a digital camera. Internal anterior chamber diameter was measured with slit-lamp adapted optical coherence tomography. Anterior chamber depth was measured using the IOL Master and slit-lamp adapted optical coherence tomography. Statistical analysis was performed using parametric tests. A Bland-Altman plot was drawn. White-to-white distance by the IOL Master was 11.8 +/- 0.40 mm, on photographs it was 11.29 +/- 0.58 mm and internal anterior chamber diameter by slit-lamp adapted optical coherence tomography was 11.34?0.54 mm. A significant difference was found between IOL-Master and slit-lamp adapted optical coherence tomography (p<0.01), as well as between IOL Master and digital photographs (p<0.01). There was no difference between SL-OCT and digital photographs (p>0.05). All measurements were correlated (Spearman p<0.001). Mean anterior chamber depth determined using the IOL-Master was 2.99 +/- 0.50 mm and by slit-lamp adapted optical coherence tomography was 2.56 +/- 0.46 mm. The difference was statistically significant (p<0.001). The correlation between the values was also statistically significant (Spearman, p<0.001). Automated measurements using IOL-Master yield constantly higher values than measurements based on direct

  8. Lightweight helmet-mounted eye movement measurement system

    NASA Technical Reports Server (NTRS)

    Barnes, J. A.

    1978-01-01

    The helmet-mounted eye movement measuring system, weighs 1,530 grams; the weight of the present aviators' helmet in standard form with the visor is 1,545 grams. The optical head is standard NAC Eye-Mark. This optical head was mounted on a magnesium yoke which in turn was attached to a slide cam mounted on the flight helmet. The slide cam allows one to adjust the eye-to-optics system distance quite easily and to secure it so that the system will remain in calibration. The design of the yoke and slide cam is such that the subject can, in an emergency, move the optical head forward and upward to the stowed and locked position atop the helmet. This feature was necessary for flight safety. The television camera that is used in the system is a solid state General Electric TN-2000 with a charged induced device imager used as the vidicon.

  9. Simulation of flashing signal operations.

    DOT National Transportation Integrated Search

    1982-01-01

    Various guidelines that have been proposed for the operation of traffic signals in the flashing mode were reviewed. The use of existing traffic simulation procedures to evaluate flashing signals was examined and a study methodology for simulating and...

  10. RNA Sequencing Reveals Differential Expression of Mitochondrial and Oxidation Reduction Genes in the Long-Lived Naked Mole-Rat When Compared to Mice

    PubMed Central

    Holmes, Andrew; Szafranski, Karol; Faulkes, Chris G.; Coen, Clive W.; Buffenstein, Rochelle; Platzer, Matthias; de Magalhães, João Pedro; Church, George M.

    2011-01-01

    The naked mole-rat (Heterocephalus glaber) is a long-lived, cancer resistant rodent and there is a great interest in identifying the adaptations responsible for these and other of its unique traits. We employed RNA sequencing to compare liver gene expression profiles between naked mole-rats and wild-derived mice. Our results indicate that genes associated with oxidoreduction and mitochondria were expressed at higher relative levels in naked mole-rats. The largest effect is nearly 300-fold higher expression of epithelial cell adhesion molecule (Epcam), a tumour-associated protein. Also of interest are the protease inhibitor, alpha2-macroglobulin (A2m), and the mitochondrial complex II subunit Sdhc, both ageing-related genes found strongly over-expressed in the naked mole-rat. These results hint at possible candidates for specifying species differences in ageing and cancer, and in particular suggest complex alterations in mitochondrial and oxidation reduction pathways in the naked mole-rat. Our differential gene expression analysis obviated the need for a reference naked mole-rat genome by employing a combination of Illumina/Solexa and 454 platforms for transcriptome sequencing and assembling transcriptome contigs of the non-sequenced species. Overall, our work provides new research foci and methods for studying the naked mole-rat's fascinating characteristics. PMID:22073188

  11. Flash Inactivation of Oxygen Evolution

    PubMed Central

    Frasch, Wayne D.; Cheniae, George M.

    1980-01-01

    Brief saturating light flashes were used to probe the mechanism of inactivation of O2 evolution by Tris in chloroplasts. Maximum inactivation with a single flash and an oscillation with period of four on subsequent flashes was observed. Analyses of the oscillations suggested that only the charge-collecting O2-evolving catalyst of photosystem II (S2-state) was a target of inactivation by Tris. This conclusion was supported by the following observations: (a) hydroxylamine preequilibration caused a three-flash delay in the inactivation pattern; (b) the lifetimes of the Tris-inactivable and S2-states were similar; and (c) reagents accelerating S2 deactivation decreased the lifetime of the inactivable state. Inactivation proved to be moderated by F, the precursor of Signal IIs, as shown by a one flash delay with chloroplasts having high abundance of F. Evidence was obtained for cooperativity effects in inactivation and NH3 was shown to be a competitive inhibitor of the Tris-induced inactivation. S2-dependent inactivation was inhibited by glutaraldehyde fixation of chloroplasts, possibly suggesting that inactivation proceeds via conformational changes of the S2-state. PMID:16661270

  12. Combined hostile fire and optics detection

    NASA Astrophysics Data System (ADS)

    Brännlund, Carl; Tidström, Jonas; Henriksson, Markus; Sjöqvist, Lars

    2013-10-01

    Snipers and other optically guided weapon systems are serious threats in military operations. We have studied a SWIR (Short Wave Infrared) camera-based system with capability to detect and locate snipers both before and after shot over a large field-of-view. The high frame rate SWIR-camera allows resolution of the temporal profile of muzzle flashes which is the infrared signature associated with the ejection of the bullet from the rifle. The capability to detect and discriminate sniper muzzle flashes with this system has been verified by FOI in earlier studies. In this work we have extended the system by adding a laser channel for optics detection. A laser diode with slit-shaped beam profile is scanned over the camera field-of-view to detect retro reflection from optical sights. The optics detection system has been tested at various distances up to 1.15 km showing the feasibility to detect rifle scopes in full daylight. The high speed camera gives the possibility to discriminate false alarms by analyzing the temporal data. The intensity variation, caused by atmospheric turbulence, enables discrimination of small sights from larger reflectors due to aperture averaging, although the targets only cover a single pixel. It is shown that optics detection can be integrated in combination with muzzle flash detection by adding a scanning rectangular laser slit. The overall optics detection capability by continuous surveillance of a relatively large field-of-view looks promising. This type of multifunctional system may become an important tool to detect snipers before and after shot.

  13. [Study on the discharge properties of xeon flash lamp and experimental measurement].

    PubMed

    Zhao, You-Quan; Miao, Pei-Liang; He, Feng; Gu, Jian; Zhai, Rui-Wei

    2014-07-01

    The Xenon flash lamp is a new type of light source for analytical instrument. The present paper analyzed the discharge process of xenon flash lamp, presented the discharge test system, and conducted experimental measurement of the voltage, current and optical pulse signal in the process of discharge. The results show that in the preliminary discharge, the free electron concentration was at a low level, so the energy was at a low level, then following the gas discharge, numerous free electrons formed in the lamp, resultin in the increase in the concentration of free electrons, therefore discharge current rised rapidly and voltage reduced. The lamp released photons to generate light pulse in the moment of ionic recombination, The pulse xenon lamp light energy output and spectral characteristic is related to electron energy in recombination and combination level of xenon, if the input energy and the energy consumption of the xenon lamp is inconsistent, it will lead to repeated capacitor charging and discharging and produce oscillation waveform. This paper is very useful for understanding the process of xenon lamp discharge, optimizing the driver circuit and the production of xenon flash lamp.

  14. Hybrid nanoporous silicon optical biosensor architectures for biological sample analysis

    NASA Astrophysics Data System (ADS)

    Bonanno, Lisa M.; Zheng, Hong; DeLouise, Lisa A.

    2010-02-01

    This work focuses on demonstrating proof-of-concept for a novel nanoparticle optical signal amplification scheme employing hybrid porous silicon (PSi) sensors. We are investigating the development of target responsive hydrogels integrated with PSi optical transducers. These hybrid-PSi sensors can be designed to provide a tunable material response to target concentration ranging from swelling to complete chain dissolution. The corresponding refractive index changes are significant and readily detected by the PSi transducer. However, to increase signal to noise, lower the limit of detection, and provide a visual read out capability, we are investigating the incorporation of high refractive index nanoparticles (NP) into the hydrogel for optical signal amplification. These NPs can be nonspecifically encapsulated, or functionalized with bioactive ligands to bind polymer chains or participate in cross linking. In this work, we demonstrate encapsulation of high refractive index QD nanoparticles into a 5wt% polyacrylamide hydrogel crosslinked with N,N'-methylenebisacrylamide (BIS) and N,N Bis-acryloyl cystamine (BAC). A QD loading (~0.29 wt%) produced a 2X larger optical shift compared to the control. Dissolution of disulphide crosslinks, using Tris[2-carboxyethyl] phosphine (TCEP) reducing agent, induced gel swelling and efficient QD release. We believe this hybrid sensor concept constitutes a versatile technology platform capable of detecting a wide range of bio/chemical targets provided target analogs can be linked to the polymer backbone and crosslinks can be achieved with target responsive multivalent receptors, such a antibodies. The optical signal amplification scheme will enable a lower limit of detection sensitivity not yet demonstrated with PSi technology and colorimetric readout visible to the naked eye.

  15. Gis-Based Crop Support System For Common Oatand Naked Oat in China

    NASA Astrophysics Data System (ADS)

    Wan, Fan; Wang, Zhen; Li, Fengmin; Cao, Huhua; Sun, Guojun

    The identification of the suitable areas for common oat (Avena sativa L.) and naked oat (Avena nuda L.) in China using Multi-Criteria Evaluation (MCE) approach based on GIS is presented in the current article. Climate, topography, soil, land use and oat variety databases were created. Relevant criteria,suitability levels and their weights for each factor were defined. Then the criteria maps were obtained and turned into the MCE process, and suitability maps for common oat and naked oat were created. The land use and the suitability maps were crossed to identify the suitable areas for each crop. The results identified 397,720 km2 of suitable areas for common oats of forage purpose distributed in 744 counties in 17 provinces, and 556,232 km2 of suitable areas for naked oats of grain purpose distributed in 779 counties in 19 provinces. This result is in accordance with the distribution of farmingpastoral ecozones located in semi-arid regions of northern China. The mapped areas can help define the working limits and serve as indicative zones for oat in China. The created databases, mapped results, interface of expert system and relevant hardware facilities could construct a complete crop support system for oats.

  16. A holographic waveguide based eye tracker

    NASA Astrophysics Data System (ADS)

    Liu, Changgeng; Pazzucconi, Beatrice; Liu, Juan; Liu, Lei; Yao, Xincheng

    2018-02-01

    We demonstrated the feasibility of using holographic waveguide for eye tracking. A custom-built holographic waveguide, a 20 mm x 60 mm x 3 mm flat glass substrate with integrated in- and out-couplers, was used for the prototype development. The in- and out-couplers, photopolymer films with holographic fringes, induced total internal reflection in the glass substrate. Diffractive optical elements were integrated into the in-coupler to serve as an optical collimator. The waveguide captured images of the anterior segment of the eye right in front of it and guided the images to a processing unit distant from the eye. The vector connecting the pupil center (PC) and the corneal reflex (CR) of the eye was used to compute eye position in the socket. An eye model, made of a high quality prosthetic eye, was used prototype validation. The benchtop prototype demonstrated a linear relationship between the angular eye position and the PC/CR vector over a range of 60 horizontal degrees and 30 vertical degrees at a resolution of 0.64-0.69 degrees/pixel by simple pixel count. The uncertainties of the measurements at different angular positions were within 1.2 pixels, which indicated that the prototype exhibited a high level of repeatability. These results confirmed that the holographic waveguide technology could be a feasible platform for developing a wearable eye tracker. Further development can lead to a compact, see-through eye tracker, which allows continuous monitoring of eye movement during real life tasks, and thus benefits diagnosis of oculomotor disorders.

  17. Influence of optic disc leakage on objective optic nerve head assessment in patients with uveitis.

    PubMed

    Heinz, Carsten; Kogelboom, Katy; Heiligenhaus, Arnd

    2016-02-01

    Secondary glaucoma is a common complication in patients with uveitis. Heidelberg Retina Tomography (HRT) and retinal nerve fiber layer (RNFL) thickness on optical coherence tomography (OCT) are widely used for examining optic nerve head changes. We evaluated these parameters in patients with uveitis and secondary glaucoma and with inflammatory papillary leakage on fluorescein angiography. Prospective single-center analysis of patients with uveitis, evaluating the impact of optic disc leakage on objective optic disc imaging parameters. Overall, 96 eyes of 59 patients were included. Papillary leakage was found in 42 eyes (43.8 %), and secondary glaucoma was found in 41 eyes (42.7 %). Glaucoma and papillary leakage were present in 12 (29 %) eyes with leakage and in 29 (54 %) eyes without leakage (p = 0.023). Neuroretinal rim area (p = 0.004), rim volume on HRT (p = 0.004), and RNFL thickness on OCT (p = 0.0008) were significantly increased in eyes with papillary leakage, while RNFL on HRT was unchanged (p = 0.255). When only eyes with normal IOP were examined, all objective parameters on OCT and HRT were significantly increased, whereas in eyes with secondary glaucoma, there was only a trend in the same direction, which did not reach significance. A comparison of eyes with secondary glaucoma and optic disc leakage to normal eyes with no glaucoma or leakage revealed no difference in any of the parameters. The objective parameters of optic nerve head imaging tools are significantly influenced by papillary leakage. In patients with secondary glaucoma and papillary leakage, these techniques are unable to detect and monitor glaucomatous damage.

  18. Study of the Radial Peripapillary Capillary Network in Congenital Optic Disc Anomalies With Optical Coherence Tomography Angiography.

    PubMed

    Cennamo, Gilda; Rossi, Claudia; Ruggiero, Pasquale; de Crecchio, Giuseppe; Cennamo, Giovanni

    2017-04-01

    To evaluate the radial peripapillary capillary network with optical coherence tomography angiography (angio-OCT) in morning glory syndrome (MGS), optic disc colobomas, and optic disc pits, and to explore possible correlations between the neural vascular structure and the pathogenesis of congenital optic disc anomalies. Prospective observational comparative case series. Fifteen eyes of 15 patients with congenital optic disc anomalies were enrolled in this study. All patients underwent angio-OCT. The scans were centered on optic discs. The mean age at presentation was 33 years (range: 19-50 years). Congenital optic disc anomalies were identified in all 15 eyes. Three eyes had the characteristic funduscopic signs of MGS, and angio-OCT scans of the peripapillary retina revealed a dense microvascular network. Optic disc colobomas were found in 5 eyes, and the characteristic funduscopic signs of optic pits were found in 7 eyes. Angio-OCT showed the absence of a radial peripapillary microvascular network in these 12 eyes. The finding that angio-OCT scans confirmed the presence of a peripapillary microvascular network only in MGS cases supports the hypothesis that a primary neuroectodermal abnormality and a secondary mesenchymal abnormality leads to MGS. Angio-OCT is a safe, rapid imaging technique that could shed light on the pathogenesis of rare diseases of the optic disc. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. The Ground Flash Fraction Retrieval Algorithm Employing Differential Evolution: Simulations and Applications

    NASA Technical Reports Server (NTRS)

    Koshak, William; Solakiewicz, Richard

    2012-01-01

    The ability to estimate the fraction of ground flashes in a set of flashes observed by a satellite lightning imager, such as the future GOES-R Geostationary Lightning Mapper (GLM), would likely improve operational and scientific applications (e.g., severe weather warnings, lightning nitrogen oxides studies, and global electric circuit analyses). A Bayesian inversion method, called the Ground Flash Fraction Retrieval Algorithm (GoFFRA), was recently developed for estimating the ground flash fraction. The method uses a constrained mixed exponential distribution model to describe a particular lightning optical measurement called the Maximum Group Area (MGA). To obtain the optimum model parameters (one of which is the desired ground flash fraction), a scalar function must be minimized. This minimization is difficult because of two problems: (1) Label Switching (LS), and (2) Parameter Identity Theft (PIT). The LS problem is well known in the literature on mixed exponential distributions, and the PIT problem was discovered in this study. Each problem occurs when one allows the numerical minimizer to freely roam through the parameter search space; this allows certain solution parameters to interchange roles which leads to fundamental ambiguities, and solution error. A major accomplishment of this study is that we have employed a state-of-the-art genetic-based global optimization algorithm called Differential Evolution (DE) that constrains the parameter search in such a way as to remove both the LS and PIT problems. To test the performance of the GoFFRA when DE is employed, we applied it to analyze simulated MGA datasets that we generated from known mixed exponential distributions. Moreover, we evaluated the GoFFRA/DE method by applying it to analyze actual MGAs derived from low-Earth orbiting lightning imaging sensor data; the actual MGA data were classified as either ground or cloud flash MGAs using National Lightning Detection Network[TM] (NLDN) data. Solution error

  20. Optimal proximity correction: application for flash memory design

    NASA Astrophysics Data System (ADS)

    Chen, Y. O.; Huang, D. L.; Sung, K. T.; Chiang, J. J.; Yu, M.; Teng, F.; Chu, Lung; Rey, Juan C.; Bernard, Douglas A.; Li, Jiangwei; Li, Junling; Moroz, V.; Boksha, Victor V.

    1998-06-01

    Proximity Correction is the technology for which the most of IC manufacturers are committed already. The final intended result of correction is affected by many factors other than the optical characteristics of the mask-stepper system, such as photoresist exposure, post-exposure bake and development parameters, etch selectivity and anisotropy, and underlying topography. The most advanced industry and research groups already reported immediate need to consider wafer topography as one of the major components during a Proximity Correction procedure. In the present work we are discussing the corners rounding effect (which eventually cause electrical leakage) observed for the elements of Poly2 layer for a Flash Memory Design. It was found that the rounding originated by three- dimensional effects due to variation of photoresist thickness resulting from the non-planar substrate. Our major goal was to understand the reasons and correct corner rounding. As a result of this work highly effective layout correction methodology was demonstrated and manufacturable Depth Of Focus was achieved. Another purpose of the work was to demonstrate complete integration flow for a Flash Memory Design based on photolithography; deposition/etch; ion implantation/oxidation/diffusion; and device simulators.