Sample records for nanoindentation specimen holder

  1. Specimen Holder for Analytical Electron Microscopes

    NASA Technical Reports Server (NTRS)

    Clanton, U. S.; Isaacs, A. M.; Mackinnon, I.

    1985-01-01

    Reduces spectral contamination by spurious X-ray. Specimen holder made of compressed carbon, securely retains standard electron microscope grid (disk) 3 mm in diameter and absorbs backscattered electrons that otherwise generate spurious X-rays. Since holder inexpensive, dedicated to single specimen when numerous samples examined.

  2. 16 CFR Figure 3 to Part 1610 - Specimen Holder Supported in Specimen Rack

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Specimen Holder Supported in Specimen Rack 3 Figure 3 to Part 1610 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT... Holder Supported in Specimen Rack ER25MR08.002 ...

  3. A simple cryo-holder facilitates specimen observation under a conventional scanning electron microscope.

    PubMed

    Tang, Chih-Yuan; Huang, Rong-Nan; Kuo-Huang, Ling-Long; Kuo, Tai-Chih; Yang, Ya-Yun; Lin, Ching-Yeh; Jane, Wann-Neng; Chen, Shiang-Jiuun

    2012-02-01

    A pre-cryogenic holder (cryo-holder) facilitating cryo-specimen observation under a conventional scanning electron microscope (SEM) is described. This cryo-holder includes a specimen-holding unit (the stub) and a cryogenic energy-storing unit (a composite of three cylinders assembled with a screw). After cooling, the cryo-holder can continue supplying cryogenic energy to extend the observation time for the specimen in a conventional SEM. Moreover, the cryogenic energy-storing unit could retain appropriate liquid nitrogen that can evaporate to prevent frost deposition on the surface of the specimen. This device is proved feasible for various tissues and cells, and can be applied to the fields of both biology and material science. We have employed this novel cryo-holder for observation of yeast cells, trichome, and epidermal cells in the leaf of Arabidopsis thaliana, compound eyes of insects, red blood cells, filiform papillae on the surface of rat tongue, agar medium, water molecules, penicillium, etc. All results suggested that the newly designed cryo-holder is applicable for cryo-specimen observation under a conventional SEM without cooling system. Most importantly, the design of this cryo-holder is simple and easy to operate and could adapt a conventional SEM to a plain type cryo-SEM affordable for most laboratories. Copyright © 2011 Wiley Periodicals, Inc.

  4. A cylindrical specimen holder for electron cryo-tomography

    PubMed Central

    Palmer, Colin M.; Löwe, Jan

    2014-01-01

    The use of slab-like flat specimens for electron cryo-tomography restricts the range of viewing angles that can be used. This leads to the “missing wedge” problem, which causes artefacts and anisotropic resolution in reconstructed tomograms. Cylindrical specimens provide a way to eliminate the problem, since they allow imaging from a full range of viewing angles around the tilt axis. Such specimens have been used before for tomography of radiation-insensitive samples at room temperature, but never for frozen-hydrated specimens. Here, we demonstrate the use of thin-walled carbon tubes as specimen holders, allowing the preparation of cylindrical frozen-hydrated samples of ribosomes, liposomes and whole bacterial cells. Images acquired from these cylinders have equal quality at all viewing angles, and the accessible tilt range is restricted only by the physical limits of the microscope. Tomographic reconstructions of these specimens demonstrate that the effects of the missing wedge are substantially reduced, and could be completely eliminated if a full tilt range was used. The overall quality of these tomograms is still lower than that obtained by existing methods, but improvements are likely in future. PMID:24275523

  5. A cylindrical specimen holder for electron cryo-tomography.

    PubMed

    Palmer, Colin M; Löwe, Jan

    2014-02-01

    The use of slab-like flat specimens for electron cryo-tomography restricts the range of viewing angles that can be used. This leads to the "missing wedge" problem, which causes artefacts and anisotropic resolution in reconstructed tomograms. Cylindrical specimens provide a way to eliminate the problem, since they allow imaging from a full range of viewing angles around the tilt axis. Such specimens have been used before for tomography of radiation-insensitive samples at room temperature, but never for frozen-hydrated specimens. Here, we demonstrate the use of thin-walled carbon tubes as specimen holders, allowing the preparation of cylindrical frozen-hydrated samples of ribosomes, liposomes and whole bacterial cells. Images acquired from these cylinders have equal quality at all viewing angles, and the accessible tilt range is restricted only by the physical limits of the microscope. Tomographic reconstructions of these specimens demonstrate that the effects of the missing wedge are substantially reduced, and could be completely eliminated if a full tilt range was used. The overall quality of these tomograms is still lower than that obtained by existing methods, but improvements are likely in future. © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Development of a specimen heating holder with an evaporator and gas injector and its application for catalyst.

    PubMed

    Takeo, Kamino; Toshie, Yaguchi; Mitsuru, Konno; Akira, Watabe; Yasuhira, Nagakubo

    2006-10-01

    A specimen heating holder equipped with a gas injector and an evaporator has been developed for use with conventional transmission electron microscopes (TEMs). The developed specimen holder allows both synthesis of metal oxide support and deposition of catalyst nano-particles in situ. Since the holder is designed to be used in small gapped high-resolution objective lens pole-piece, all the procedure from the synthesis of support material to the deposition of catalyst as well as the behavior of the catalyst nano-particles on the support can be observed at near atomic resolution. The developed specimen holder was applied to the study of AuPd catalyst. First, air was injected onto heated aluminum particles via a gas injector to synthesize Al(2)O(3) support. Then, nano-particles of AuPd were deposited on the Al(2)O(3) support. After the deposition, the synthesized Al(2)O(3) support was heated and air was injected again to observe behaviors of the deposited AuPd nano-particles at elevated temperatures in the aerial environment. Behaviors of the AuPd nano-particles such as coalescence, segmentation and diffusion to the Al(2)O(3) support were dynamically observed at atomic level high resolution.

  7. Sample holder for axial rotation of specimens in 3D microscopy.

    PubMed

    Bruns, T; Schickinger, S; Schneckenburger, H

    2015-10-01

    In common light microscopy, observation of samples is only possible from one perspective. However, especially for larger three-dimensional specimens observation from different views is desirable. Therefore, we are presenting a sample holder permitting rotation of the specimen around an axis perpendicular to the light path of the microscope. Thus, images can be put into a defined multidimensional context, enabling reliable three-dimensional reconstructions. The device can be easily adapted to a great variety of common light microscopes and is suitable for various applications in science, education and industry, where the observation of three-dimensional specimens is essential. Fluorescence z-projection images of copepods and ixodidae ticks at different rotation angles obtained by confocal laser scanning microscopy and light sheet fluorescence microscopy are reported as representative results. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  8. Relationship between Yield Point Phenomena and the Nanoindentation Pop-in Behavior of Steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahn, T.-H.; Oh, C.-S.; Lee, K.

    2012-01-01

    Pop-ins on nanoindentation load-displacement curves of a ferritic steel were correlated with yield drops on its tensile stress-strain curves. To investigate the relationship between these two phenomena, nanoindentation and tensile tests were performed on annealed specimens, prestrained specimens, and specimens aged for various times after prestraining. Clear nanoindentation pop-ins were observed on annealed specimens, which disappeared when specimens were indented right after the prestrain, but reappeared to varying degrees after strain aging. Yield drops in tensile tests showed similar disappearance and appearance, indicating that the two phenomena, at the nano- and macro-scale, respectively, are closely related and influenced by dislocationmore » locking by solutes (Cottrell atmospheres).« less

  9. Experimental method to account for structural compliance in nanoindentation measurements

    Treesearch

    Joseph E. Jakes; Charles R. Frihart; James F. Beecher; Robert J. Moon; D. S. Stone

    2008-01-01

    The standard Oliver–Pharr nanoindentation analysis tacitly assumes that the specimen is structurally rigid and that it is both semi-infinite and homogeneous. Many specimens violate these assumptions. We show that when the specimen flexes or possesses heterogeneities, such as free edges or interfaces between regions of different properties, artifacts arise...

  10. Interfacial modulus mapping of layered dental ceramics using nanoindentation

    PubMed Central

    Bushby, Andrew J; P'ng, Ken MY; Wilson, Rory M

    2016-01-01

    PURPOSE The aim of this study was to test the modulus of elasticity (E) across the interfaces of yttria stabilized zirconia (YTZP) / veneer multilayers using nanoindentation. MATERIALS AND METHODS YTZP core material (KaVo-Everest, Germany) specimens were either coated with a liner (IPS e.max ZirLiner, Ivoclar-Vivadent) (Type-1) or left as-sintered (Type-2) and subsequently veneered with a pressable glass-ceramic (IPS e.max ZirPress, Ivoclar-Vivadent). A 5 µm (nominal tip diameter) spherical indenter was used with a UMIS CSIRO 2000 (ASI, Canberra, Australia) nanoindenter system to test E across the exposed and polished interfaces of both specimen types. The multiple point load – partial unload method was used for E determination. All materials used were characterized using Scanning Electron Microscopy (SEM) and X – ray powder diffraction (XRD). E mappings of the areas tested were produced from the nanoindentation data. RESULTS A significantly (P<.05) lower E value between Type-1 and Type-2 specimens at a distance of 40 µm in the veneer material was associated with the liner. XRD and SEM characterization of the zirconia sample showed a fine grained bulk tetragonal phase. IPS e-max ZirPress and IPS e-max ZirLiner materials were characterized as amorphous. CONCLUSION The liner between the YTZP core and the heat pressed veneer may act as a weak link in this dental multilayer due to its significantly (P<.05) lower E. The present study has shown nanoindentation using spherical indentation and the multiple point load - partial unload method to be reliable predictors of E and useful evaluation tools for layered dental ceramic interfaces. PMID:28018566

  11. Specimen loading list for the varying temperature experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qualls, A.L.; Sitterson, R.G.

    1998-09-01

    The varying temperature experiment HFIR-RB-13J has been assembled and inserted in the reactor. Approximately 5300 specimens were cleaned, inspected, matched, and loaded into four specimen holders. A listing of each specimen loaded into the steady temperature holder, its position in the capsule, and the identification of the corresponding specimen loaded into the varying temperature holder is presented in this report.

  12. A Method for Measuring the Hardness of the Surface Layer on Hot Forging Dies Using a Nanoindenter

    NASA Astrophysics Data System (ADS)

    Mencin, P.; van Tyne, C. J.; Levy, B. S.

    2009-11-01

    The properties and characteristics of the surface layer of forging dies are critical for understanding and controlling wear. However, the surface layer is very thin, and appropriate property measurements are difficult to obtain. The objective of the present study is to determine if nanoindenter testing provides a reliable method, which could be used to measure the surface hardness in forging die steels. To test the reliability of nanoindenter testing, nanoindenter values for two quenched and tempered steels (FX and H13) are compared to microhardness and macrohardness values. These steels were heat treated for various times to produce specimens with different values of hardness. The heat-treated specimens were tested using three different instruments—a Rockwell hardness tester for macrohardness, a Vickers hardness tester for microhardness, and a nanoindenter tester for fine scale evaluation of hardness. The results of this study indicate that nanoindenter values obtained using a Nanoindenter XP Machine with a Berkovich indenter reliably correlate with Rockwell C macrohardness values, and with Vickers HV microhardness values. Consequently, nanoindenter testing can provide reliable results for analyzing the surface layer of hot forging dies.

  13. Comparisons of nanoindentation, 3-point bending, and tension tests for orthodontic wires.

    PubMed

    Iijima, Masahiro; Muguruma, Takeshi; Brantley, William A; Mizoguchi, Itaru

    2011-07-01

    The purposes of this study were to obtain information about mechanical properties with the nanoindentation test for representative wire alloys and compare the results with conventional mechanical tests. Archwires having 0.016 × 0.022-in cross sections were obtained of 1 stainless steel, 1 cobalt-chromium-nickel, 1 beta-titanium alloy, and 2 nickel-titanium products. Specimens of as-received wires were subjected to nanoindentation testing along the external surfaces and over polished cross sections to obtain values of hardness and elastic modulus. Other specimens of as-received wires were subjected to Vickers hardness, 3-point bending, and tension tests. All testing was performed at 25°C. Differences were found in hardness and elastic modulus obtained with the nanoindentation test at the external and cross-sectioned surfaces and with the conventional mechanical-property tests. Mechanical properties obtained with the nanoindentation test generally varied with indentation depth. The 3 testing methods did not yield identical values of hardness and elastic modulus, although the order among the 5 wire products was the same. Variations in results for the nanoindentation and conventional mechanical property tests can be attributed to the different material volumes sampled, different work-hardening levels, and an oxide layer on the wire surface. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  14. A novel sample preparation method to avoid influence of embedding medium during nano-indentation

    Treesearch

    Yujie Meng; Siqun Wang; Zhiyong Cai; Timothy M. Young; Guanben Du; Yanjun Li

    2012-01-01

    The effect of the embedding medium on the nano-indentation measurements of lignocellulosic materials was investigated experimentally using nano-indentation. Both the reduced elastic modulus and the hardness of nonembedded cell walls were found to be lower than those of the embedded samples, proving that the embedding medium used for specimen preparation on cellulosic...

  15. Modeling and Simulation of Nanoindentation

    NASA Astrophysics Data System (ADS)

    Huang, Sixie; Zhou, Caizhi

    2017-11-01

    Nanoindentation is a hardness test method applied to small volumes of material which can provide some unique effects and spark many related research activities. To fully understand the phenomena observed during nanoindentation tests, modeling and simulation methods have been developed to predict the mechanical response of materials during nanoindentation. However, challenges remain with those computational approaches, because of their length scale, predictive capability, and accuracy. This article reviews recent progress and challenges for modeling and simulation of nanoindentation, including an overview of molecular dynamics, the quasicontinuum method, discrete dislocation dynamics, and the crystal plasticity finite element method, and discusses how to integrate multiscale modeling approaches seamlessly with experimental studies to understand the length-scale effects and microstructure evolution during nanoindentation tests, creating a unique opportunity to establish new calibration procedures for the nanoindentation technique.

  16. Automatic grinding apparatus to control uniform specimen thicknesses

    DOEpatents

    Bryner, Joseph S.

    1982-01-01

    This invention is directed to a new and improved grinding apparatus comprising (1) a movable grinding surface, (2) a specimen holder, (3) a displacing device for moving the holder and/or grinding surface toward one another, and (4) at least three devices for limiting displacement of the holder to the grinding surface.

  17. Automatic grinding apparatus to control uniform specimen thicknesses

    DOEpatents

    Bryner, J.S.

    1981-01-07

    This invention is directed to a new and improved grinding apparatus comprisng: (1) a movable grinding surface; (2) a specimen holder; (3) a dislacing means for moving the holder and/or grinding surface toward one another; and (4) at least three means for limiting displacement of the holder to the grinding surface.

  18. Durability of crystalline phase in concrete microstructure modified by the mineral powders: evaluation by nanoindentation tests

    NASA Astrophysics Data System (ADS)

    Rajczakowska, Magdalena; Łydżba, Dariusz

    2016-03-01

    This paper presents the nanoindentation investigation of the evolution of concrete microstructure modified by the Internal Crystallization Technology mineral powders. The samples under study were retrieved from a fragment of a circular concrete lining of the vertical mine shaft at a depth of approximately 1,000 m. Due to the aggressive environment and exposure to contaminated water, the internal surface of the structure was deteriorated, decreasing its strength significantly. The mineral powders were applied directly on the surface lining. The specimens were investigated one month, three months and one year after the application of the aforementioned substance in order to verify the time dependence of the strengthening processes and durability of the crystalline phase. The microstructural changes of concrete were assessed with the use of nanoindentation technique. The testing procedure involved including the previously cut specimens in the epoxy resin and grinding and polishing in order to reduce the surface roughness. As a result of the nanoindentation tests the hardness as well as Young's modulus of the material were evaluated. The results were then compared and statistically analyzed. As a consequence, the disintegration time of the crystalline network in the pores of concrete was identified.

  19. Report on the Installation and Preparedness of a Protochips Fusion in-situ Heating Holder for TEM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edmondson, Philip D.

    2017-03-01

    This brief report documents the procurement and installation of a Protochips Fusion (formerly Aduro) high-temperature, high stability transmission electron microscopy (TEM) specimen holder that allows for the high spatial resolution characterization of material specimens at high temperature in situ of an electron microscope. This specimen holder was specifically procured for use with The FEI Talos F200X Scanning/Transmission Electron Microscope (STEM) in Oak Ridge National Laboratory’s (ORNL’s) Low Activation Materials Development and Analysis (LAMDA) Laboratory. The Protochips Fusion holder will enable high-resolution structural and chemical analysis of irradiated materials at high temperature, becoming a unique capability worldwide, and would encourage high-qualitymore » in situ experiments to be conducted on irradiated materials.« less

  20. Nano-indentation investigation on the mechanical stability of individual austenite in high-carbon steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qiao, Xun; Han, Lizhan; Zhang, Weimin

    2015-12-15

    Quenching (AQ) and cryogenic treatments (QC) were conducted on the high-carbon SAE 52100 steel to investigate the mechanical stability of individual retained austenite (RA) by nano-indentation. The cross-sections of indented RA region prepared by focused ion beam (FIB) were examined by using transmission electron microscopy (TEM). For the first time, it was directly observed that some parts of RA grain, closest to the indent, in AQ specimen had transformed into strain-induced martensite (SIM). However, not any pop-in or transformation was detected in the indented QC specimen. This clearly indicates that the mechanical stability of RA in QC seems significantly enhanced,more » which is mainly attributed to the cryogenic treatment resulting in a higher carbon enrichment of RA compared to that in AQ. Furthermore, a higher load of external stress may need to trigger its martensitic transformation in QC specimen. - Highlights: • Mechanical stability of retained austenite was studied by nano-indentation and TEM. • The strain-induced martensite transformation in RA was observed under applied load. • Cryogenic treatment enhances mechanical stability of RA due to carbon enrichment.« less

  1. High-Throughput Nanoindentation for Statistical and Spatial Property Determination

    NASA Astrophysics Data System (ADS)

    Hintsala, Eric D.; Hangen, Ude; Stauffer, Douglas D.

    2018-04-01

    Standard nanoindentation tests are "high throughput" compared to nearly all other mechanical tests, such as tension or compression. However, the typical rates of tens of tests per hour can be significantly improved. These higher testing rates enable otherwise impractical studies requiring several thousands of indents, such as high-resolution property mapping and detailed statistical studies. However, care must be taken to avoid systematic errors in the measurement, including choosing of the indentation depth/spacing to avoid overlap of plastic zones, pileup, and influence of neighboring microstructural features in the material being tested. Furthermore, since fast loading rates are required, the strain rate sensitivity must also be considered. A review of these effects is given, with the emphasis placed on making complimentary standard nanoindentation measurements to address these issues. Experimental applications of the technique, including mapping of welds, microstructures, and composites with varying length scales, along with studying the effect of surface roughness on nominally homogeneous specimens, will be presented.

  2. Motorized manipulator for positioning a TEM specimen

    DOEpatents

    Schmid, Andreas Karl; Andresen, Nord

    2010-12-14

    The invention relates to a motorized manipulator for positioning a TEM specimen holder with sub-micron resolution parallel to a y-z plane and rotating the specimen holder in the y-z plane, the manipulator comprising a base (2), and attachment means (30) for attaching the specimen holder to the manipulator, characterized in that the manipulator further comprises at least three nano-actuators (3.sup.a, 3.sup.b, 3.sup.c) mounted on the base, each nano-actuator showing a tip (4.sup.a, 4.sup.b, 4.sup.c), the at least three tips defining the y-z plane, each tip capable of moving with respect to the base in the y-z plane; a platform (5) in contact with the tips of the nano-actuators; and clamping means (6) for pressing the platform against the tips of the nano-actuators; as a result of which the nano-actuators can rotate the platform with respect to the base in the y-z plane and translate the platform parallel to the y-z plane.

  3. In Situ TEM Study of Interaction between Dislocations and a Single Nanotwin under Nanoindentation.

    PubMed

    Wang, Bo; Zhang, Zhenyu; Cui, Junfeng; Jiang, Nan; Lyu, Jilei; Chen, Guoxin; Wang, Jia; Liu, Zhiduo; Yu, Jinhong; Lin, Chengte; Ye, Fei; Guo, Dongming

    2017-09-06

    Nanotwinned (nt) materials exhibit excellent mechanical properties, and have been attracting much more attention of late. Nevertheless, the fundamental mechanism of interaction between dislocations and a single nanotwin is not understood. In this study, in situ transmission electron microscopy (TEM) nanoindentation is performed, on a specimen of a nickel (Ni) alloy containing a single nanotwin of 89 nm in thickness. The specimen is prepared using focused ion beam (FIB) technique from an nt surface, which is formed by a novel approach under indentation using a developed diamond panel with tips array. The stiffness of the specimen is ten times that of the pristine counterparts during loading. The ultrahigh stiffness is attributed to the generation of nanotwins and the impediment of the single twin to the dislocations. Two peak loads are induced by the activation of a new slip system and the penetration of dislocations over the single nanotwin, respectively. One slip band is parallel to the single nanotwin, indicating the slip of dislocations along the nanotwin. In situ TEM observation of nanoindentation reveals a new insight for the interaction between dislocations and a single nanotwin. This paves the way for design and preparation of high-performance nt surfaces of Ni alloys used for aircraft engines, gas turbines, turbocharger components, ducts, and absorbers.

  4. Fracture toughness of bleached enamel: Effect of applying three different nanobiomaterials by nanoindentation test.

    PubMed

    Khoroushi, Maryam; Mazaheri, Hamid; Saneie, Tahere; Samimi, Pouran

    2016-01-01

    Despite the absence of dispute about the efficacy of bleaching agents, a prime concern is about their compromising effect on the enamel structure. This in vitro study investigated whether the addition of three different biomaterials, including nano-bioactive glass (n-BG)/nano-hydroxy apetite (n-HA)/nano-amorphous calcium phosphate (n-ACP), to bleaching agents can affect the fracture toughness (FT) and vickers hardness number (VHN) of bovine enamel. The crowns of the newly extracted permanent bovine incisors teeth were separated from the root and sectioned along their central line; one half serving as the control specimen and the other half as the test specimen. After mounting and polishing procedure, all the control specimens (C) were subjected to nano-indentation test to obtain the baseline values of FT. Then, the control specimens were exposed to a 38% hydrogen peroxide for four times, each time for 10 min. The test specimens were divided into three groups and treated as follows, with the same protocol used for the control specimens: Group 1; ACP + hydrogen peroxide (HP) mixed gel; Group 2 BG + HP mixed gel; and Group 3 HA + HP mixed gel. FT measurements with nano-indentation were carried out subsequent to bleaching experiments. Data were analyzed using SPSS and Kruskal-Wallis test (α = 0.05). A significant difference in young's modulus (YM), VHN, and FT at baseline and subsequent to bleaching in control group was observed. However, no significant differences were found in YM, VHN, and FT between the test groups, compared to the respective baseline values. Under the limitations of the current study, it can be concluded that the n-HA, n-ACP, and n-BG could be potential biomaterials used to reduce the adverse effects of tooth bleaching.

  5. Fracture toughness of bleached enamel: Effect of applying three different nanobiomaterials by nanoindentation test

    PubMed Central

    Khoroushi, Maryam; Mazaheri, Hamid; Saneie, Tahere; Samimi, Pouran

    2016-01-01

    Background: Despite the absence of dispute about the efficacy of bleaching agents, a prime concern is about their compromising effect on the enamel structure. This in vitro study investigated whether the addition of three different biomaterials, including nano-bioactive glass (n-BG)/nano-hydroxy apetite (n-HA)/nano-amorphous calcium phosphate (n-ACP), to bleaching agents can affect the fracture toughness (FT) and vickers hardness number (VHN) of bovine enamel. Materials and Methods: The crowns of the newly extracted permanent bovine incisors teeth were separated from the root and sectioned along their central line; one half serving as the control specimen and the other half as the test specimen. After mounting and polishing procedure, all the control specimens (C) were subjected to nano-indentation test to obtain the baseline values of FT. Then, the control specimens were exposed to a 38% hydrogen peroxide for four times, each time for 10 min. The test specimens were divided into three groups and treated as follows, with the same protocol used for the control specimens: Group 1; ACP + hydrogen peroxide (HP) mixed gel; Group 2 BG + HP mixed gel; and Group 3 HA + HP mixed gel. FT measurements with nano-indentation were carried out subsequent to bleaching experiments. Data were analyzed using SPSS and Kruskal–Wallis test (α = 0.05). Results: A significant difference in young's modulus (YM), VHN, and FT at baseline and subsequent to bleaching in control group was observed. However, no significant differences were found in YM, VHN, and FT between the test groups, compared to the respective baseline values. Conclusion: Under the limitations of the current study, it can be concluded that the n-HA, n-ACP, and n-BG could be potential biomaterials used to reduce the adverse effects of tooth bleaching. PMID:27307669

  6. Spherical nanoindentation stress-strain analysis, Version 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weaver, Jordan S.; Turner, David; Miller, Calvin

    Nanoindentation is a tool that allows the mechanical response of a variety of materials at the nano to micron length scale to be measured. Recent advances in spherical nanoindentation techniques have allowed for a more reliable and meaningful characterization of the mechanical response from nanoindentation experiments in the form on an indentation stress-strain curve. This code base, Spin, is written in MATLAB (The Mathworks, Inc.) and based on the analysis protocols developed by S.R. Kalidindi and S. Pathak [1, 2]. The inputs include the displacement, load, harmonic contact stiffness, harmonic displacement, and harmonic load from spherical nanoindentation tests in themore » form of an Excel (Microsoft) spreadsheet. The outputs include indentation stress-strain curves and indentation properties as well their variance due to the uncertainty of the zero-point correction in the form of MATLAB data (.mat) and figures (.png). [1] S. Pathak, S.R. Kalidindi. Spherical nanoindentation stress–strain curves, Mater. Sci. Eng R-Rep 91 (2015). [2] S.R. Kalidindi, S. Pathak. Determination of the effective zero-point and the extraction of spherical nanoindentation stress-strain curves, Acta Materialia 56 (2008) 3523-3532.« less

  7. TEM-nanoindentation studies of semiconducting structures.

    PubMed

    Le Bourhis, E; Patriarche, G

    2007-01-01

    This paper reviews the application of nanoindentation coupled with transmission electron microscopy (TEM) to investigations of the plastic behaviour of semiconducting structures and its implication for device design. Instrumented nanoindentation has been developed to extract the mechanical behaviour of small volumes scaled to those encountered in semiconductor heterostructures. We illustrate that TEM is a powerful complementary tool for the study of local plasticity induced by nanoindentation. TEM-nanoindentation allows for detailed understanding of the plastic deformation in semiconducting structures and opens practical routes for improvement of devices. Performances of heterostructures are deteriously affected by dislocations that relax the lattice mismatched layers. Different ways to obtain compliant substructures are being developed in order to concentrate the plastic relaxation underneath the heterostructure. Such approaches allow for mechanical design of micro- and opto-electronic devices to be considered throughout the fabrication process.

  8. Mechanical response of dental cements as determined by nanoindentation and scanning electron microscopy.

    PubMed

    Saghiri, Mohammad Ali; Nazari, Amir; Garcia-Godoy, Franklin; Asatourian, Armen; Malekzadeh, Mansour; Elyasi, Maryam

    2013-12-01

    This study evaluated the effects of nanoindentation on the surface of white mineral trioxide aggregate (WMTA), Bioaggregate and Nano WMTA cements. Cements were mixed according to the manufacturer directions, condensed inside glass tubes, and randomly divided into three groups (n = 8). Specimens were soaked in synthetic tissue fluid (pH = 7.4) and incubated for 3 days. Cement pellets were subjected to nanoindentation tests and observed by scanning electron microscopy. Then, the images were processed and the number of cracks and total surface area of defects on the surface were calculated and analyzed using ImageJ. Data were submitted to one-way analysis of variance and a post hoc Tukey's test. The lowest number of cracks and total surface of defects were detected in Nano WMTA samples; however, it was not significantly different from WMTA samples (p = 0.588), while the highest values were noticed in Bioaggregate specimens that were significantly different from Nano WMTA and WMTA (p = 0.0001). The surface of WMTA and Nano WMTA showed more resistance after exposure to nano-compressive forces which indicated a better surface tolerance against these forces and crack formation. This suggests these substances are more tolerant cement materials which can predictably withstand loaded situations in a clinical scenario.

  9. A novel sample preparation method to avoid influence of embedding medium during nano-indentation

    NASA Astrophysics Data System (ADS)

    Meng, Yujie; Wang, Siqun; Cai, Zhiyong; Young, Timothy M.; Du, Guanben; Li, Yanjun

    2013-02-01

    The effect of the embedding medium on the nano-indentation measurements of lignocellulosic materials was investigated experimentally using nano-indentation. Both the reduced elastic modulus and the hardness of non-embedded cell walls were found to be lower than those of the embedded samples, proving that the embedding medium used for specimen preparation on cellulosic material during nano-indentation can modify cell-wall properties. This leads to structural and chemical changes in the cell-wall constituents, changes that may significantly alter the material properties. Further investigation was carried out to detect the influence of different vacuum times on the cell-wall mechanical properties during the embedding procedure. Interpretation of the statistical analysis revealed no linear relationships between vacuum time and the mechanical properties of cell walls. The quantitative measurements confirm that low-viscosity resin has a rapid penetration rate early in the curing process. Finally, a novel sample preparation method aimed at preventing resin diffusion into lignocellulosic cell walls was developed using a plastic film to wrap the sample before embedding. This method proved to be accessible and straightforward for many kinds of lignocellulosic material, but is especially suitable for small, soft samples.

  10. Atomistic simulation study of influence of Al2O3-Al interface on dislocation interaction and prismatic loop formation during nano-indentation on Al2O3-coated aluminum.

    PubMed

    Mishra, Srishti; Meraj, Md; Pal, Snehanshu

    2018-06-19

    A large-scale molecular dynamics (MD) simulation of nano-indentation was carried out to provide insight into the influence of the Al-Al 2 O 3 interface on dislocation evolution and deformation behavior of Al substrate coated with Al 2 O 3 thin film. Adaptive common neighbor analysis (a-CNA), centro-symmetry parameter (CSP) estimation, and dislocation extraction algorithm (DXA) were implemented to represent structural evolution during nano-indentation deformation. The absence of elastic regime was observed in the P-h curve for this simulated nano-indentation test of Al 2 O 3 thin film coated Al specimen. The displacement of oxygen atoms from Al 2 O 3 to Al partly through the interface greatly influences the plastic deformation behavior of the specimen during nano-indentation. Prismatic dislocation loops, which are formed due to pinning of Shockley partials (1/6 < 112>) by Stair-rod (1/6 < 110>) and Hirth dislocation (1/3 < 001>), were observed in all cases studied in this work. Pile-up of atoms was also observed and the extent of the pile-up was found to vary with the test temperature. A distorted stacking fault tetrahedron (SFT) is formed when a nano-indentation test is carried out at 100 K. The presence of a prismatic dislocation loop, SFT and dislocation forest caused strain hardening and, consequently, there is an increase in hardness as indentation depth increases. Graphical abstract Figure illustrates nano-indentation model set up along with load vs. depth curve and distorted stacking fault tetrahedron.

  11. Flame Holder System

    NASA Technical Reports Server (NTRS)

    Haskin, Henry H. (Inventor); Vasquez, Peter (Inventor)

    2013-01-01

    A flame holder system includes a modified torch body and a ceramic flame holder. Catch pin(s) are coupled to and extend radially out from the torch body. The ceramic flame holder has groove(s) formed in its inner wall that correspond in number and positioning to the catch pin(s). Each groove starts at one end of the flame holder and can be shaped to define at least two 90.degree.turns. Each groove is sized to receive one catch pin therein when the flame holder is fitted over the end of the torch body. The flame holder is then manipulated until the catch pin(s) butt up against the end of the groove(s).

  12. Quantitative prediction of phase transformations in silicon during nanoindentation

    NASA Astrophysics Data System (ADS)

    Zhang, Liangchi; Basak, Animesh

    2013-08-01

    This paper establishes the first quantitative relationship between the phases transformed in silicon and the shape characteristics of nanoindentation curves. Based on an integrated analysis using TEM and unit cell properties of phases, the volumes of the phases emerged in a nanoindentation are formulated as a function of pop-out size and depth of nanoindentation impression. This simple formula enables a fast, accurate and quantitative prediction of the phases in a nanoindentation cycle, which has been impossible before.

  13. Nanomechanical investigation of ion implanted single crystals - Challenges, possibilities and pitfall traps related to nanoindentation

    NASA Astrophysics Data System (ADS)

    Kurpaska, Lukasz

    2017-10-01

    Nanoindentation technique have developed considerably over last thirty years. Nowadays, commercially available systems offer very precise measurement in nano- and microscale, environmental noise cancelling (or at least noise suppressing), in situ high temperature indentation in controlled atmosphere and vacuum conditions and different additional options, among them dedicated indentation is one of the most popular. Due to its high precision, and ability to measure mechanical properties from very small depths (tens of nm), this technique become quite popular in the nuclear society. It is known that ion implantation (to some extent) can simulate the influence of neutron flux. However, depth of the material damage is very limited resulting in creation of thin layer of modified material over unmodified bulk. Therefore, only very precise technique, offering possibility to control depth of the measurement can be used to study functional properties of the material. For this reason, nanoindentation technique seems to be a perfect tool to investigate mechanical properties of ion implanted specimens. However, conducting correct nanomechanical experiment and extracting valuable mechanical parameters is not an easy task. In this paper a discussion about the nanoindentation tests performed on ion irradiated YSZ single crystal is presented. The goal of this paper is to discuss possible traps when studying mechanical properties of such materials and thin coatings.

  14. Nanoindentation of Electropolished FeCrAl Alloy Welds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weaver, Jordan; Aydogan, Eda; Mara, Nathan Allan

    The present report summarizes Berkovich nanoindentation modulus and hardness measurements on two candidate FeCrAl alloys (C35M and C37M) on as-received (AR) and welded samples. In addition, spherical nanoindentation stress-strain measurements were performed on individual grains to provide further information and demonstrate the applicability of these protocols to mechanically characterizing welds in FeCrAl alloys. The indentation results are compared against the reported tensile properties for these alloys to provide relationships between nanoindentation and tensile tests and insight into weldsoftening for these FeCrAl alloys. Hardness measurements revealed weld-softening for both alloys in good agreement with tensile test results. C35M showed a largermore » reduction in hardness at the weld center from the AR material compared to C37M; this is also consistent with tensile tests. In general, nanohardness was shown to be a good predictor of tensile yield strength and ultimate tensile stress for FeCrAl alloys. Spherical nanoindentation measurements revealed that the fusion zone (FZ) + heat affected zone (HAZ) has a very low defect density typical of well-annealed metals as indicated by the frequent pop-in events. Spherical nanoindentation yield strength, Berkovich hardness, and tensile yield strength measurements on the welded material all show that the C37M welded material has a higher strength than C35M welded material. From the comparison of nanoindentation and tensile tests, EBSD microstructure analysis, and information on the processing history, it can be deduced that the primary driver for weld-softening is a change in the defect structure at the grain-scale between the AR and welded material. These measurements serve as baseline data for utilizing nanoindentation for studying the effects of radiation damage on these alloys.« less

  15. Experimental research on a modular miniaturization nanoindentation device

    NASA Astrophysics Data System (ADS)

    Huang, Hu; Zhao, Hongwei; Mi, Jie; Yang, Jie; Wan, Shunguang; Yang, Zhaojun; Yan, Jiwang; Ma, Zhichao; Geng, Chunyang

    2011-09-01

    Nanoindentation technology is developing toward the in situ test which requires miniaturization of indentation instruments. This paper presents a miniaturization nanoindentation device based on the modular idea. It mainly consists of macro-adjusting mechanism, x-y precise positioning platform, z axis precise driving unit, and the load-depth measuring unit. The device can be assembled with different forms and has minimum dimensions of 200 mm × 135 mm × 200 mm. The load resolution is about 0.1 mN and the displacement resolution is about 10 nm. A new calibration method named the reference-mapping method is proposed to calibrate the developed device. Output performance tests and indentation experiments indicate the feasibility of the developed device and calibration method. This paper gives an example that combining piezoelectric actuators with flexure hinge to realize nanoindentation tests. Integrating a smaller displacement sensor, a more compact nanoindentation device can be designed in the future.

  16. Nanoindentation of silicon implanted with hydrogen: effect of implantation dose on silicon’s mechanical properties and nanoindentation-induced phase transformation

    NASA Astrophysics Data System (ADS)

    Jelenković, Emil V.; To, Suet; Goncharova, Lyudmila V.; Wong, Sing Fai

    2017-07-01

    Implantation of hydrogen in single-crystal silicon (c-Si) is known to affect its machining. However, very little is reported on the material and mechanical properties of hydrogen-implanted silicon (Si). In this article, near-surface regions (~0-500 nm) of lightly doped (1 0 0) Si were modified by varying the hydrogen concentration using ion implantation. The maximum hydrogen concentration was varied from ~4  ×  1020 to ~3.2  ×  1021 cm-3. The implanted Si was investigated by nanoindentation. From the dynamic nanoindentation test, it was found that in hydrogen-implanted Si hardness is increased significantly, while the elastic modulus is reduced. The nanoindentation-induced Si phase transformation was studied under different load/unload rates and loads. Raman spectroscopy revealed that the hydrogen implantation tends to suppress Si-XII and Si-III phases and facilitates amorphous Si formation during the unloading stage of nanoindentation. Both the mechanical properties and phase transformations were qualitatively related not only to the hydrogen concentration, but also to the implantation-generated defects and strain.

  17. Ultra high vacuum heating and rotating specimen stage

    DOEpatents

    Coombs, III, Arthur W.

    1995-01-01

    A heating and rotating specimen stage provides for simultaneous specimen heating and rotating. The stage is ideally suited for operation in ultrahigh vacuum (1.times.10.sup.-9 torr or less), but is useful at atmosphere and in pressurized systems as well. A specimen is placed on a specimen holder that is attached to a heater that, in turn, is attached to a top housing. The top housing is rotated relative to a bottom housing and electrically connected thereto by electrically conductive brushes. This stage is made of materials that are compatible with UHV, able to withstand high temperatures, possess low outgassing rates, are gall and seize resistant, and are able to carry substantial electrical loading without overheating.

  18. DIY Tomography sample holder

    NASA Astrophysics Data System (ADS)

    Lari, L.; Wright, I.; Boyes, E. D.

    2015-10-01

    A very simple tomography sample holder at minimal cost was developed in-house. The holder is based on a JEOL single tilt fast exchange sample holder where its exchangeable tip was modified to allow high angle degree tilt. The shape of the tip was designed to retain mechanical stability while minimising the lateral size of the tip. The sample can be mounted on as for a standard 3mm Cu grids as well as semi-circular grids from FIB sample preparation. Applications of the holder on different sample systems are shown.

  19. Interfacial diffusion aided deformation during nanoindentation

    DOE PAGES

    Samanta, Amit; E., Weinan

    2015-07-06

    Nanoindentation is commonly used to quantify the mechanical response of material surfaces. Despite its widespread use, a detailed understanding of the deformation mechanisms responsible for plasticity during these experiments has remained elusive. Nanoindentation measurements often show stress values close to a material’s ideal strength which suggests that dislocation nucleation and subsequent dislocation activity dominates the deformation. However, low strain-rate exponents and small activation volumes have also been reported which indicates high temperature sensitivity of the deformation processes. Using an order parameter aided temperature accelerated sampling technique called adiabatic free energy dynamics [J. B. Abrams and M. E. Tuckerman, J. Phys.more » Chem. B, 112, 15742 (2008)], and molecular dynamics we have probed the diffusive mode of deformation during nanoindentation. Localized processes such as surface vacancy and ad-atom pair formation, vacancy diffusion are found to play an important role during indentation. Furthermore, our analysis suggests a change in the dominant deformation mode from dislocation mediated plasticity to diffusional flow at high temperatures, slow indentation rates and small indenter tip radii.« less

  20. A Nano-indentation Identification Technique for Viscoelastic Constitutive Characteristics of Periodontal Ligaments

    PubMed Central

    Ashrafi, H.; Shariyat, M.

    2016-01-01

    Introduction Nano-indentation has recently been employed as a powerful tool for determining the mechanical properties of biological tissues on nano and micro scales. A majority of soft biological tissues such as ligaments and tendons exhibit viscoelastic or time-dependent behaviors. The constitutive characterization of soft tissues is among very important subjects in clinical medicine and especially, biomechanics fields. Periodontal ligament plays an important role in initiating tooth movement when loads are applied to teeth with orthodontic appliances. It is also the most accessible ligament in human body as it can be directly manipulated without any surgical intervention. From a mechanical point of view, this ligament can be considered as a thin interface made by a solid phase, consisting mainly of collagen fibers, which is immersed into a so-called ground substance. However, the viscoelastic constitutive effects of biological tissues are seldom considered rigorous during Nano-indentation tests. Methods In the present paper, a mathematical contact approach is developed to enable determining creep compliance and relaxation modulus of distinct periodontal ligaments, using constant–rate indentation and loading time histories, respectively. An adequate curve-fitting method is presented to determine these characteristics based on the Nano-indentation of rigid Berkovich tips. Generalized Voigt-Kelvin and Wiechert models are used to model constitutive equations of periodontal ligaments, in which the relaxation and creep functions are represented by series of decaying exponential functions of time. Results Time-dependent creep compliance and relaxation function have been obtained for tissue specimens of periodontal ligaments. Conclusion To improve accuracy, relaxation and creep moduli are measured from two tests separately. Stress relaxation effects appear more rapidly than creep in the periodontal ligaments. PMID:27672630

  1. A Nano-indentation Identification Technique for Viscoelastic Constitutive Characteristics of Periodontal Ligaments.

    PubMed

    Ashrafi, H; Shariyat, M

    2016-06-01

    Nano-indentation has recently been employed as a powerful tool for determining the mechanical properties of biological tissues on nano and micro scales. A majority of soft biological tissues such as ligaments and tendons exhibit viscoelastic or time-dependent behaviors. The constitutive characterization of soft tissues is among very important subjects in clinical medicine and especially, biomechanics fields. Periodontal ligament plays an important role in initiating tooth movement when loads are applied to teeth with orthodontic appliances. It is also the most accessible ligament in human body as it can be directly manipulated without any surgical intervention. From a mechanical point of view, this ligament can be considered as a thin interface made by a solid phase, consisting mainly of collagen fibers, which is immersed into a so-called ground substance. However, the viscoelastic constitutive effects of biological tissues are seldom considered rigorous during Nano-indentation tests. In the present paper, a mathematical contact approach is developed to enable determining creep compliance and relaxation modulus of distinct periodontal ligaments, using constant-rate indentation and loading time histories, respectively. An adequate curve-fitting method is presented to determine these characteristics based on the Nano-indentation of rigid Berkovich tips. Generalized Voigt-Kelvin and Wiechert models are used to model constitutive equations of periodontal ligaments, in which the relaxation and creep functions are represented by series of decaying exponential functions of time. Time-dependent creep compliance and relaxation function have been obtained for tissue specimens of periodontal ligaments. To improve accuracy, relaxation and creep moduli are measured from two tests separately. Stress relaxation effects appear more rapidly than creep in the periodontal ligaments.

  2. Ultra high vacuum heating and rotating specimen stage

    DOEpatents

    Coombs, A.W. III

    1995-05-02

    A heating and rotating specimen stage provides for simultaneous specimen heating and rotating. The stage is ideally suited for operation in ultrahigh vacuum (1{times}10{sup {minus}9} torr or less), but is useful at atmosphere and in pressurized systems as well. A specimen is placed on a specimen holder that is attached to a heater that, in turn, is attached to a top housing. The top housing is rotated relative to a bottom housing and electrically connected thereto by electrically conductive brushes. This stage is made of materials that are compatible with UHV, able to withstand high temperatures, possess low outgassing rates, are gall and seize resistant, and are able to carry substantial electrical loading without overheating. 5 figs.

  3. EBSD and Nanoindentation-Correlated Study of Delamination Fracture in Al-Li Alloy 2090

    NASA Technical Reports Server (NTRS)

    Tayon, Wesley A.; Crooks, Roy E.; Domack, Marcia S.; Wagner, John A.; Elmustafa, A. A.

    2008-01-01

    Al-Li alloys offer attractive combinations of high strength and low density. However, a tendency for delamination fracture has limited their use. A better understanding of the delamination mechanisms may identify methods to control delaminations through processing modifications. A combination of new techniques has been used to evaluate delamination fracture in Al-Li alloys. Both high quality electron backscattered diffraction (EBSD) information and valid nanoindentation measurements were obtained from fractured test specimens. Correlations were drawn between nano-scale hardness variations and local texture along delaminating boundaries. Intriguing findings were observed for delamination fracture through the combined analysis of grain orientation, Taylor factor, and kernel average misorientation.

  4. Characterization of Viscoelastic Properties of Polymeric Materials Through Nanoindentation

    NASA Technical Reports Server (NTRS)

    Odegard, G. M.; Bandorawalla, T.; Herring, H. M.; Gates, T. S.

    2003-01-01

    Nanoindentation is used to determine the dynamic viscoelastic properties of six polymer materials. It is shown that varying the harmonic frequency of the nanoindentation does not have any significant effect on the measured storage and loss moduli of the polymers. Agreement is found between these results and data from DMA testing of the same materials. Varying the harmonic amplitude of the nanoindentation does not have a significant effect on the measured properties of the high performance resins, however, the storage modulus of the polyethylene decreases as the harmonic amplitude increases. Measured storage and loss moduli are also shown to depend on the density of the polyethylene.

  5. Characterization of phase properties and deformation in ferritic-austenitic duplex stainless steels by nanoindentation and finite element method

    DOE PAGES

    Schwarm, Samuel C.; Kolli, R. Prakash; Aydogan, Eda; ...

    2016-11-03

    The phase properties and deformation behavior of the δ–ferrite and γ–austenite phases of CF–3 and CF–8 cast duplex stainless steels were characterized by nanoindentation and microstructure-based finite element method (FEM) models. We evaluated the elastic modulus of each phase and the results indicate that the mean elastic modulus of the δ–ferrite phase is greater than that of the γ–austenite phase, and the mean nanoindentation hardness values of each phase are approximately the same. Furthermore, the elastic FEM model results illustrate that greater von Mises stresses are located within the δ–ferrite phase, while greater von Mises strains are located in themore » γ–austenite phase in response to elastic deformation. The elastic moduli calculated by FEM agree closely with those measured by tensile testing. Finally, the plastically deformed specimens exhibit an increase in misorientation, deformed grains, and subgrain structure formation as measured by electron backscatter diffraction (EBSD).« less

  6. Characterization of phase properties and deformation in ferritic-austenitic duplex stainless steels by nanoindentation and finite element method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwarm, Samuel C.; Kolli, R. Prakash; Aydogan, Eda

    The phase properties and deformation behavior of the δ–ferrite and γ–austenite phases of CF–3 and CF–8 cast duplex stainless steels were characterized by nanoindentation and microstructure-based finite element method (FEM) models. We evaluated the elastic modulus of each phase and the results indicate that the mean elastic modulus of the δ–ferrite phase is greater than that of the γ–austenite phase, and the mean nanoindentation hardness values of each phase are approximately the same. Furthermore, the elastic FEM model results illustrate that greater von Mises stresses are located within the δ–ferrite phase, while greater von Mises strains are located in themore » γ–austenite phase in response to elastic deformation. The elastic moduli calculated by FEM agree closely with those measured by tensile testing. Finally, the plastically deformed specimens exhibit an increase in misorientation, deformed grains, and subgrain structure formation as measured by electron backscatter diffraction (EBSD).« less

  7. Preset pivotal tool holder

    DOEpatents

    Asmanes, Charles

    1979-01-01

    A tool fixture is provided for precise pre-alignment of a radiused edge cutting tool in a tool holder relative to a fixed reference pivot point established on said holder about which the tool holder may be selectively pivoted relative to the fixture base member to change the contact point of the tool cutting edge with a workpiece while maintaining the precise same tool cutting radius relative to the reference pivot point.

  8. Sample holder with optical features

    DOEpatents

    Milas, Mirko; Zhu, Yimei; Rameau, Jonathan David

    2013-07-30

    A sample holder for holding a sample to be observed for research purposes, particularly in a transmission electron microscope (TEM), generally includes an external alignment part for directing a light beam in a predetermined beam direction, a sample holder body in optical communication with the external alignment part and a sample support member disposed at a distal end of the sample holder body opposite the external alignment part for holding a sample to be analyzed. The sample holder body defines an internal conduit for the light beam and the sample support member includes a light beam positioner for directing the light beam between the sample holder body and the sample held by the sample support member.

  9. Apparatus for X-ray diffraction microscopy and tomography of cryo specimens

    DOE PAGES

    Beetz, T.; Howells, M. R.; Jacobsen, C.; ...

    2005-03-14

    An apparatus for diffraction microscopy of biological and materials science specimens is described. In this system, a coherent soft X-ray beam is selected with a pinhole, and the illuminated specimen is followed by an adjustable beamstop and CCD camera to record diffraction data from non-crystalline specimens. In addition, a Fresnel zone plate can be inserted to allow for direct imaging. The system makes use of a cryogenic specimen holder with cryotransfer capabilities to allow frozen hydrated specimens to be loaded. The specimen can be tilted over a range of ± 80 ° degrees for three-dimensional imaging; this is done bymore » computer-controlled motors, enabling automated alignment of the specimen through a tilt series. The system is now in use for experiments in soft X-ray diffraction microscopy.« less

  10. Specimen illumination apparatus with optical cavity for dark field illumination

    DOEpatents

    Pinkel, Daniel; Sudar, Damir; Albertson, Donna

    1999-01-01

    An illumination apparatus with a specimen slide holder, an illumination source, an optical cavity producing multiple reflection of illumination light to a specimen comprising a first and a second reflective surface arranged to achieve multiple reflections of light to a specimen is provided. The apparatus can further include additional reflective surfaces to achieve the optical cavity, a slide for mounting the specimen, a coverslip which is a reflective component of the optical cavity, one or more prisms for directing light within the optical cavity, antifading solutions for improving the viewing properties of the specimen, an array of materials for analysis, fluorescent components, curved reflective surfaces as components of the optical cavity, specimen detection apparatus, optical detection equipment, computers for analysis of optical images, a plane polarizer, fiberoptics, light transmission apertures, microscopic components, lenses for viewing the specimen, and upper and lower mirrors above and below the specimen slide as components of the optical cavity. Methods of using the apparatus are also provided.

  11. Evaluation of the phase properties of hydrating cement composite using simulated nanoindentation technique

    NASA Astrophysics Data System (ADS)

    Gautham, S.; Sindu, B. S.; Sasmal, Saptarshi

    2017-10-01

    Properties and distribution of the products formed during the hydration of cementitious composite at the microlevel are investigated using a nanoindentation technique. First, numerical nanoindentation using nonlinear contact mechanics is carried out on three different phase compositions of cement paste, viz. mono-phase Tri-calcium Silicate (C3S), Di-calcium Silicate (C2S) and Calcium-Silicate-Hydrate (CSH) individually), bi-phase (C3S-CSH, C2S-CSH) and multi-phase (more than 10 individual phases including water pores). To reflect the multi-phase characteristics of hydrating cement composite, a discretized multi-phase microstructural model of cement composite during the progression of hydration is developed. Further, a grid indentation technique for simulated nanoindentation is established, and employed to evaluate the mechanical characteristics of the hydrated multi-phase cement paste. The properties obtained from the numerical studies are compared with those obtained from experimental grid nanoindentation. The influence of composition and distribution of individual phase properties on the properties obtained from indentation are closely investigated. The study paves the way to establishing the procedure for simulated grid nanoindentation to evaluate the mechanical properties of heterogeneous composites, and facilitates the design of experimental nanoindentation.

  12. The evolution of machining-induced surface of single-crystal FCC copper via nanoindentation

    NASA Astrophysics Data System (ADS)

    Zhang, Lin; Huang, Hu; Zhao, Hongwei; Ma, Zhichao; Yang, Yihan; Hu, Xiaoli

    2013-05-01

    The physical properties of the machining-induced new surface depend on the performance of the initial defect surface and deformed layer in the subsurface of the bulk material. In this paper, three-dimensional molecular dynamics simulations of nanoindentation are preformed on the single-point diamond turning surface of single-crystal copper comparing with that of pristine single-crystal face-centered cubic copper. The simulation results indicate that the nucleation of dislocations in the nanoindentation test on the machining-induced surface and pristine single-crystal copper is different. The dislocation embryos are gradually developed from the sites of homogeneous random nucleation around the indenter in the pristine single-crystal specimen, while the dislocation embryos derived from the vacancy-related defects are distributed in the damage layer of the subsurface beneath the machining-induced surface. The results show that the hardness of the machining-induced surface is softer than that of pristine single-crystal copper. Then, the nanocutting simulations are performed along different crystal orientations on the same crystal surface. It is shown that the crystal orientation directly influences the dislocation formation and distribution of the machining-induced surface. The crystal orientation of nanocutting is further verified to affect both residual defect generations and their propagation directions which are important in assessing the change of mechanical properties, such as hardness and Young's modulus, after nanocutting process.

  13. Effects of specimen preparation on the electromagnetic property measurements of solid materials with an automatic network analyzer

    NASA Technical Reports Server (NTRS)

    Long, E. R., Jr.

    1986-01-01

    Effects of specimen preparation on measured values of an acrylic's electomagnetic properties at X-band microwave frequencies, TE sub 1,0 mode, utilizing an automatic network analyzer have been studied. For 1 percent or less error, a gap between the specimen edge and the 0.901-in. wall of the specimen holder was the most significant parameter. The gap had to be less than 0.002 in. The thickness variation and alignment errors in the direction parallel to the 0.901-in. wall were equally second most significant and had to be less than 1 degree. Errors in the measurement f the thickness were third most significant. They had to be less than 3 percent. The following parameters caused errors of 1 percent or less: ratios of specimen-holder thicknesses of more than 15 percent, gaps between the specimen edge and the 0.401-in. wall less than 0.045 in., position errors less than 15 percent, surface roughness, hickness variation in the direction parallel to the 0.401-in. wall less than 35 percent, and specimen alignment in the direction parallel to the 0.401-in. wall mass than 5 degrees.

  14. Solid-state-laser-rod holder

    DOEpatents

    Gettemy, D.J.; Barnes, N.P.; Griggs, J.E.

    1981-08-11

    The disclosure relates to a solid state laser rod holder comprising Invar, copper tubing, and epoxy joints. Materials and coefficients of expansion of the components of the holder combine with the rod to produce a joint which will give before the rod itself will. The rod may be lased at about 70 to 80/sup 0/K and returned from such a temperature to room temperature repeatedly without its or the holder's destruction.

  15. Mechanical properties of multilayered films using different nanoindenters.

    PubMed

    Fang, Te-Hua; Wang, Tong Hong; Wu, Jia-Hung

    2010-07-01

    The effects of interface, contact hardness, deformation, and adhesion of Al/Ni multilayered films under nanoindentation were investigated using molecular dynamics (MD) simulations. The results show that the indentation force of the sphere indenter is the largest among nanoindentations using sphere, cone, Vickers, or Berkovich type indenters at the same penetration depth. Force increasing, relaxation and adhesion took place during loading, holding depth and unloading, respectively. The interface occurred along the {111} (110) slip systems and the maximum width of the glide bands was about 1 nm. The reaction force and plastic energy of the indented films are also discussed.

  16. Method for determining the effects of oxygen plasma on a specimen

    NASA Technical Reports Server (NTRS)

    Whitaker, Ann F. (Inventor)

    1991-01-01

    A method for determining the effects of exposure of oxygen plasma on a specimen such as a thin film polymer or thin metals. The method includes providing an apparatus with a chamber having a holder supporting the polymer specimen in a plasma environment provided in the chamber. The chamber is regulated to a predetermined pressure and set temperature prior to the introduction of oxygen plasma therein. The specimen is then subjected to the plasma environment for a predetermined time during which time the temperature of the specimen is sensed and regulated to be maintained at the set temperature. Temperature sensing is accomplished by a probe which senses any changes in bulk sample temperature. Temperature regulation is provided by a thermoelectric module and by a coolant flow tube.

  17. On the failure load and mechanism of polycrystalline graphene by nanoindentation

    PubMed Central

    Sha, Z. D.; Wan, Q.; Pei, Q. X.; Quek, S. S.; Liu, Z. S.; Zhang, Y. W.; Shenoy, V. B.

    2014-01-01

    Nanoindentation has been recently used to measure the mechanical properties of polycrystalline graphene. However, the measured failure loads are found to be scattered widely and vary from lab to lab. We perform molecular dynamics simulations of nanoindentation on polycrystalline graphene at different sites including grain center, grain boundary (GB), GB triple junction, and holes. Depending on the relative position between the indenter tip and defects, significant scattering in failure load is observed. This scattering is found to arise from a combination of the non-uniform stress state, varied and weakened strengths of different defects, and the relative location between the indenter tip and the defects in polycrystalline graphene. Consequently, the failure behavior of polycrystalline graphene by nanoindentation is critically dependent on the indentation site, and is thus distinct from uniaxial tensile loading. Our work highlights the importance of the interaction between the indentation tip and defects, and the need to explicitly consider the defect characteristics at and near the indentation site in polycrystalline graphene during nanoindentation. PMID:25500732

  18. 3D printing scanning electron microscopy sample holders: A quick and cost effective alternative for custom holder fabrication.

    PubMed

    Meloni, Gabriel N; Bertotti, Mauro

    2017-01-01

    A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM) sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder.

  19. 3D printing scanning electron microscopy sample holders: A quick and cost effective alternative for custom holder fabrication

    PubMed Central

    Bertotti, Mauro

    2017-01-01

    A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM) sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder. PMID:28753638

  20. Double acting bit holder

    DOEpatents

    Morrell, Roger J.; Larson, David A.; Ruzzi, Peter L.

    1994-01-01

    A double acting bit holder that permits bits held in it to be resharpened during cutting action to increase energy efficiency by reducing the amount of small chips produced. The holder consist of: a stationary base portion capable of being fixed to a cutter head of an excavation machine and having an integral extension therefrom with a bore hole therethrough to accommodate a pin shaft; a movable portion coextensive with the base having a pin shaft integrally extending therefrom that is insertable in the bore hole of the base member to permit the moveable portion to rotate about the axis of the pin shaft; a recess in the movable portion of the holder to accommodate a shank of a bit; and a biased spring disposed in adjoining openings in the base and moveable portions of the holder to permit the moveable portion to pivot around the pin shaft during cutting action of a bit fixed in a turret to allow front, mid and back positions of the bit during cutting to lessen creation of small chip amounts and resharpen the bit during excavation use.

  1. Calculation of recirculating flow behind flame-holders

    NASA Astrophysics Data System (ADS)

    Zeng, Q.; Sheng, Y.; Zhou, Q.

    1985-10-01

    Adoptability of standard K-epsilon turbulence model for numerical calculation of recirculating flow is discussed. Many computations of recirculating flows behind bluff-bodies used as flame-holders in afterburner of aeroengine have been completed. Blocking-off method to treat the incline walls of the flame-holder gives good results. In isothermal recirculating flows the flame-holder wall is assumed to be isolated. Therefore, it is possible to remove the inactive zone from the calculation domain in programming to save computer time. The computation for a V-shaped flame-holder exhibits an interesting phenomenon that the recirculation zone extends to the cavity of the flame-holder.

  2. Nanoindentation size effects in wood

    Treesearch

    Joseph E. Jakes; Donald S. Stone; Charles R. Frihart

    2007-01-01

    The purpose of this work was to test some of the assumptions underlying methods currently employed to investigate nanoindentation properties of wood. We examined whether hardness and modulus depend on load. We employed a surface preparation technique that minimizes alterations of cell wall properties. Areas were determined using both (a) Oliver-Pharr method and (b) a...

  3. Electromyographic comparison of forearm muscle movements for fine skin suturing between an enlarged pen needle holder and a webster needle holder.

    PubMed

    Ohata, Erika; Matsuo, Kiyoshi; Ban, Ryokuya; Shiba, Masato; Yasunaga, Yoshichika

    2013-01-01

    For surgical suturing, a Webster needle holder uses wrist supinating with supinator and extrinsic muscles, whereas a pen needle holder uses finger twisting with intrinsic and extrinsic muscles. Because the latter is better suited to microsurgery, which requires fine suturing with less forearm muscle movement, we have recently adopted an enlarged pen needle holder scaled from a micro needle holder for fine skin suturing. In this study, we assessed whether the enlarged pen needle holder reduced forearm muscle movement during fine skin suturing as compared with the Webster needle holder. A fine skin-suturing task was performed using pen holding with the enlarged micro needle holder or scissor holding with the Webster needle holder by 9 experienced and 6 inexperienced microsurgeons. The task lasted for 60 seconds and was randomly performed 3 times for each method. Forearm flexor and extensor muscular activities were evaluated by surface electromyography. The enlarged pen needle holder method required significantly less forearm muscle movement for experienced microsurgeons despite it being their first time using the instrument. There was no significant difference between 2 methods for inexperienced microsurgeons. Experienced microsurgeons conserved forearm muscle movement by finger twisting in fine skin suturing with the enlarged pen needle holder. Inexperienced microsurgeons may benefit from the enlarged pen needle holder, even for fine skin suturing, to develop their internal acquisition model of the dynamics of finger twisting.

  4. 19 CFR 10.7 - Substantial containers or holders.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Substantial containers or holders. 10.7 Section 10... Exported and Returned § 10.7 Substantial containers or holders. (a) Substantial containers or holders... domestic products exported and returned. When such containers or holders are imported not containing or...

  5. Nanoindentation on SnAgCu lead-free solder joints and analysis

    NASA Astrophysics Data System (ADS)

    Xu, Luhua; Pang, John H. L.

    2006-12-01

    The lead-free SnAgCu (SAC) solder joint on copper pad with organic solderability preservative (Cu-OSP) and electroless nickel and immersion gold (ENIG) subjected to thermal testing leads to intermetallic growth. It causes corresponding reliability concerns at the interface. Nanoindentation characterization on SnAgCu solder alloy, intermetallic compounds (IMCs), and the substrates subjected to thermal aging is reported. The modulus and hardness of thin IMC layers were measured by nanoindentation continuous stiffness measurement (CSM) from planar IMC surface. When SAC/Ni(Au) solder joints were subject to thermal aging, the Young’s modulus of the NiCuSn IMC at the SAC/ENIG specimen changed from 207 GPa to 146 GPa with different aging times up to 500 h. The hardness decreased from 10.0 GPa to 7.3 GPa. For the SAC/Cu-OSP reaction couple, the Young’s modulus of Cu6Sn5 stayed constant at 97.0 GPa and hardness about 5.7 GPa. Electron-probe microanalysis (EPMA) was used to thermal aging. The creep effect on the measured result was analyzed when measuring SnAgCu solder; it was found that the indentation penetration, and thus the hardness, is loading rate dependent. With the proposed constant P/P experiment, a constant indentation strain rate h/h and hardness could be achieved. The log-log plot of indentation strain rate versus hardness for the data from the constant P/P experiments yields a slope of 7.52. With the optimized test method and CSM Technique, the Modulus of SAC387 solder alloy and all the layers in a solder joint were investigated.

  6. 24 CFR 290.19 - Restrictions concerning nondiscrimination against Section 8 certificate holders and voucher holders.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... PROPERTIES DISPOSITION OF MULTIFAMILY PROJECTS AND SALE OF HUD-HELD MULTIFAMILY MORTGAGES Disposition of Multifamily Projects § 290.19 Restrictions concerning nondiscrimination against Section 8 certificate holders and voucher holders. The purchaser of any multifamily housing project shall not refuse unreasonably to...

  7. 24 CFR 290.19 - Restrictions concerning nondiscrimination against Section 8 certificate holders and voucher holders.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... PROPERTIES DISPOSITION OF MULTIFAMILY PROJECTS AND SALE OF HUD-HELD MULTIFAMILY MORTGAGES Disposition of Multifamily Projects § 290.19 Restrictions concerning nondiscrimination against Section 8 certificate holders and voucher holders. The purchaser of any multifamily housing project shall not refuse unreasonably to...

  8. 24 CFR 290.19 - Restrictions concerning nondiscrimination against Section 8 certificate holders and voucher holders.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... PROPERTIES DISPOSITION OF MULTIFAMILY PROJECTS AND SALE OF HUD-HELD MULTIFAMILY MORTGAGES Disposition of Multifamily Projects § 290.19 Restrictions concerning nondiscrimination against Section 8 certificate holders and voucher holders. The purchaser of any multifamily housing project shall not refuse unreasonably to...

  9. 24 CFR 290.19 - Restrictions concerning nondiscrimination against Section 8 certificate holders and voucher holders.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... PROPERTIES DISPOSITION OF MULTIFAMILY PROJECTS AND SALE OF HUD-HELD MULTIFAMILY MORTGAGES Disposition of Multifamily Projects § 290.19 Restrictions concerning nondiscrimination against Section 8 certificate holders and voucher holders. The purchaser of any multifamily housing project shall not refuse unreasonably to...

  10. Electromyographic Comparison of Forearm Muscle Movements for Fine Skin Suturing Between an Enlarged Pen Needle Holder and a Webster Needle Holder

    PubMed Central

    Ohata, Erika; Matsuo, Kiyoshi; Ban, Ryokuya; Shiba, Masato; Yasunaga, Yoshichika

    2013-01-01

    Background: For surgical suturing, a Webster needle holder uses wrist supinating with supinator and extrinsic muscles, whereas a pen needle holder uses finger twisting with intrinsic and extrinsic muscles. Because the latter is better suited to microsurgery, which requires fine suturing with less forearm muscle movement, we have recently adopted an enlarged pen needle holder scaled from a micro needle holder for fine skin suturing. In this study, we assessed whether the enlarged pen needle holder reduced forearm muscle movement during fine skin suturing as compared with the Webster needle holder. Methods: A fine skin-suturing task was performed using pen holding with the enlarged micro needle holder or scissor holding with the Webster needle holder by 9 experienced and 6 inexperienced microsurgeons. The task lasted for 60 seconds and was randomly performed 3 times for each method. Forearm flexor and extensor muscular activities were evaluated by surface electromyography. Results: The enlarged pen needle holder method required significantly less forearm muscle movement for experienced microsurgeons despite it being their first time using the instrument. There was no significant difference between 2 methods for inexperienced microsurgeons. Conclusions: Experienced microsurgeons conserved forearm muscle movement by finger twisting in fine skin suturing with the enlarged pen needle holder. Inexperienced microsurgeons may benefit from the enlarged pen needle holder, even for fine skin suturing, to develop their internal acquisition model of the dynamics of finger twisting. PMID:23691259

  11. Practical aspects of the use of the X(2) holder for HRTEM-quality TEM sample preparation by FIB.

    PubMed

    van Mierlo, Willem; Geiger, Dorin; Robins, Alan; Stumpf, Matthias; Ray, Mary Louise; Fischione, Paul; Kaiser, Ute

    2014-12-01

    The X(2) holder enables the effective production of thin, electron transparent samples for high-resolution transmission electron microscopy (HRTEM). Improvements to the X(2) holder for high-quality transmission electron microscopy (TEM) sample preparation are presented in this paper. We discuss the influence of backscattered electrons (BSE) from the sample holder in determining the lamella thickness in situ and demonstrate that a significant improvement in thickness determination can be achieved by comparatively simple means using the relative BSE intensity. We show (using Monte Carlo simulations) that by taking into account the finite collection angle of the electron backscatter detector, an approximately 20% underestimation of the lamella thickness in a silicon sample can be avoided. However, a correct thickness determination for light-element lamellas still remains a problem with the backscatter method; we introduce a more accurate method using the energy dispersive X-ray spectroscopy (EDX) signal for in situ thickness determination. Finally, we demonstrate how to produce a thin lamella with a nearly damage-free surface using the X(2) holder in combination with sub-kV polishing in the Fischione Instruments׳ NanoMill(®) TEM specimen preparation system. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Invited Article: Indenter materials for high temperature nanoindentation

    NASA Astrophysics Data System (ADS)

    Wheeler, J. M.; Michler, J.

    2013-10-01

    As nanoindentation at high temperatures becomes increasingly popular, a review of indenter materials for usage at high temperatures is instructive for identifying appropriate indenter-sample materials combinations to prevent indenter loss or failure due to chemical reactions or wear during indentation. This is an important consideration for nanoindentation as extremely small volumes of reacted indenter material will have a significant effect on measurements. The high temperature hardness, elastic modulus, thermal properties, and chemical reactivities of diamond, boron carbide, silicon carbide, tungsten carbide, cubic boron nitride, and sapphire are discussed. Diamond and boron carbide show the best elevated temperature hardness, while tungsten carbide demonstrates the lowest chemical reactivity with the widest array of elements.

  13. Suppression of nanoindentation-induced phase transformation in crystalline silicon implanted with hydrogen

    NASA Astrophysics Data System (ADS)

    Jelenković, Emil V.; To, Suet

    2017-09-01

    In this paper the effect of hydrogen implantation in silicon on nanoindentation-induced phase transformation is investigated. Hydrogen ions were implanted in silicon through 300 nm thick oxide with double energy implantation (75 and 40 keV). For both energies implantation dose was 4 × 1016 cm-2. Some samples were thermally annealed at 400 °C. The micro-Raman spectroscopy was applied on nanoindentation imprints and the obtained results were related to the pop out/elbow appearances in nanoindentatioin unloading-displacement curves. The Raman spectroscopy revealed a suppression of Si-XII and Si-III phases and formation of a-Si in the indents of hydrogen implanted Si. The high-resolution x-ray diffraction measurements were taken to support the analysis of silicon phase formation during nanoindentation. Implantation induced strain, high hydrogen concentration, and platelets generation were found to be the factors that control suppression of c-Si phases Si-XII and Si-III, as well as a-Si phase enhancement during nanoindentation. [Figure not available: see fulltext.

  14. Structure-property-glass transition relationships in non-isocyanate polyurethanes investigated by dynamic nanoindentation

    NASA Astrophysics Data System (ADS)

    Weyand, Stephan; Blattmann, Hannes; Schimpf, Vitalij; Mülhaupt, Rolf; Schwaiger, Ruth

    2016-07-01

    Newly developed green-chemistry approaches towards the synthesis of non-isocyanate polyurethane (NIPU) systems represent a promising alternative to polyurethanes (PU) eliminating the need for harmful ingredients. A series of NIPU systems were studied using different nanoindentation techniques in order to understand the influence of molecular parameters on the mechanical behavior. Nanoindentation revealed a unique characteristic feature of those materials, i.e. stiffening with increasing deformation. It is argued that the origin of this observed stiffening is a consequence of the thermodynamic state of the polymer network, the molecular characteristics of the chemical building blocks and resulting anisotropic elastic response of the network structure. Flat-punch nanoindentation was applied in order to characterize the constitutive viscoelastic nature of the materials. The complex modulus shows distinct changes as a function of the NIPU network topology illustrating the influence of the chemical building blocks. The reproducibility of the data indicates that the materials are homogeneous over the volumes sampled by nanoindentation. Our study demonstrates that nanoindentation is very well-suited to investigate the molecular characteristics of NIPU materials that cannot be quantified in conventional experiments. Moreover, the technique provides insight into the functional significance of complex molecular architectures thereby supporting the development of NIPU materials with tailored properties.

  15. Deformation Mechanisms of Gum Metals Under Nanoindentation

    NASA Astrophysics Data System (ADS)

    Sankaran, Rohini Priya

    defect structures to applied loading, we perform ex-situ nanoindentation. Nanoindentation is a convenient method as the plastic deformation is localized and probes a nominally defect free volume of the material. We subsequently characterize the defect structures in these alloys with both conventional TEM and advanced techniques such as HAADF HRSTEM and nanoprobe diffraction. These advanced techniques allow for a more thorough understanding of the observed deformation features. The main findings from this investigation are as follows. As expected we observe that a non-equilibrium phase, o, is present in the leaner beta-stabilized alloy, ST Ref-1. We do not find any direct evidence of secondary phases in STGM, and we find the beta phase in CWGM, along with lath microstructure with subgrain structure consisting of dislocation cell networks. Upon nanoindentation, we find twinning accompanied by beta nucleation on the twin boundary in ST Ref-1 samples. This result is consistent with previous findings and is reasonable considering the alloy is unstable with respect to beta transformation. We find deformation nanotwinning in cold worked gum metals under nanoindentation, which is initially surprising. We argue that when viewed as a nanocrystalline material, such a deformation mechanism is consistent with previous work, and furthermore, a deformation nanotwinned structure does not preclude an ideal shear mechanism from operating in the alloy. Lastly, we observe continuous lattice rotations in STGM under nanoindentation via nanoprobe diffraction. With this technique, for the first time we can demonstrate that the lattice rotations are truly continuous at the nanoscale. We can quantify this lattice rotation, and find that even though the rotation is large, it may be mediated by a reasonable geometrically necessary dislocation density, and note that similar rotations are typically observed in other materials under nanoindentation. HRSTEM and conventional TEM data confirm the

  16. Manipulator for rotating and translating a sample holder

    DOEpatents

    van de Water, Jeroen [Breugel, NL; van den Oetelaar, Johannes [Eindhoven, NL; Wagner, Raymond [Gorinchem, NL; Slingerland, Hendrik Nicolaas [Venlo, NL; Bruggers, Jan Willem [Eindhoven, NL; Ottevanger, Adriaan Huibert Dirk [Malden, NL; Schmid, Andreas [Berkeley, CA; Olson, Eric A [Champaign, IL; Petrov, Ivan G [Champaign, IL; Donchev, Todor I [Urbana, IL; Duden, Thomas [Kensington, CA

    2011-02-08

    A manipulator for use in e.g. a Transmission Electron Microscope (TEM) is described, said manipulator capable of rotating and translating a sample holder (4). The manipulator clasps the round sample holder between two members (3A, 3B), said members mounted on actuators (2A, 2B). Moving the actuators in the same direction results in a translation of the sample holder, while moving the actuators in opposite directions results in a rotation of the sample holder.

  17. Parameter estimation of a nonlinear Burger's model using nanoindentation and finite element-based inverse analysis

    NASA Astrophysics Data System (ADS)

    Hamim, Salah Uddin Ahmed

    Nanoindentation involves probing a hard diamond tip into a material, where the load and the displacement experienced by the tip is recorded continuously. This load-displacement data is a direct function of material's innate stress-strain behavior. Thus, theoretically it is possible to extract mechanical properties of a material through nanoindentation. However, due to various nonlinearities associated with nanoindentation the process of interpreting load-displacement data into material properties is difficult. Although, simple elastic behavior can be characterized easily, a method to characterize complicated material behavior such as nonlinear viscoelasticity is still lacking. In this study, a nanoindentation-based material characterization technique is developed to characterize soft materials exhibiting nonlinear viscoelasticity. Nanoindentation experiment was modeled in finite element analysis software (ABAQUS), where a nonlinear viscoelastic behavior was incorporated using user-defined subroutine (UMAT). The model parameters were calibrated using a process called inverse analysis. In this study, a surrogate model-based approach was used for the inverse analysis. The different factors affecting the surrogate model performance are analyzed in order to optimize the performance with respect to the computational cost.

  18. Transmission electron microscope sample holder with optical features

    DOEpatents

    Milas, Mirko [Port Jefferson, NY; Zhu, Yimei [Stony Brook, NY; Rameau, Jonathan David [Coram, NY

    2012-03-27

    A sample holder for holding a sample to be observed for research purposes, particularly in a transmission electron microscope (TEM), generally includes an external alignment part for directing a light beam in a predetermined beam direction, a sample holder body in optical communication with the external alignment part and a sample support member disposed at a distal end of the sample holder body opposite the external alignment part for holding a sample to be analyzed. The sample holder body defines an internal conduit for the light beam and the sample support member includes a light beam positioner for directing the light beam between the sample holder body and the sample held by the sample support member.

  19. Porous coolant tube holder for fuel cell stack

    DOEpatents

    Guthrie, Robin J.

    1981-01-01

    A coolant tube holder for a stack of fuel cells is a gas porous sheet of fibrous material adapted to be sandwiched between a cell electrode and a nonporous, gas impervious flat plate which separates adjacent cells. The porous holder has channels in one surface with coolant tubes disposed therein for carrying coolant through the stack. The gas impervious plate is preferably bonded to the opposite surface of the holder, and the channel depth is the full thickness of the holder.

  20. Mechanical Properties of Uranium Silicides by Nanoindentation and Finite Elements Modeling

    NASA Astrophysics Data System (ADS)

    Carvajal-Nunez, U.; Elbakhshwan, M. S.; Mara, N. A.; White, J. T.; Nelson, A. T.

    2018-02-01

    Three methods were used to measure the mechanical properties of {U}3{Si}, {U}_3{Si}2, and USi. Quasi-static and continuous stiffness measurement nanoindentation were used to determine hardness and Young's modulus, and microindentation was used to evaluate the bulk hardness. Hardness and Young's modulus of the three U-Si compounds were both observed to increase with Si content. Finally, finite elements modelling was used to validate the nanoindentation data calculated for {U}3{Si}2 and estimate its yield strength.

  1. 78 FR 44957 - Agency Information Collection Activities: BioWatch Filter Holder Log, Filter Holder Log DHS Form...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-25

    ... DEPARTMENT OF HOMELAND SECURITY Agency Information Collection Activities: BioWatch Filter Holder Log, Filter Holder Log DHS Form 9500 AGENCY: Office of Health Affairs, DHS. ACTION: 60-Day Notice and....: Daniel Yereb, [email protected] 703- 647-8052. SUPPLEMENTARY INFORMATION: Following collection, the filter...

  2. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  3. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  4. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  5. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  6. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  7. Mechanical Properties of Uranium Silicides by Nanoindentation and Finite Elements Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carvajal-Nunez, U.; Elbakhshwan, M. S.; Mara, N. A.

    Three methods were used to measure the mechanical properties of U 3Si, U 3Si 2, and USi. Quasi-static and continuous stiffness measurement nanoindentation were used to determine hardness and Young’s modulus, and microindentation was used to evaluate the bulk hardness. Hardness and Young’s modulus of the three U-Si compounds were both observed to increase with Si content. In conclusion, finite elements modelling was used to validate the nanoindentation data calculated for U 3Si 2 and estimate its yield strength.

  8. Mechanical Properties of Uranium Silicides by Nanoindentation and Finite Elements Modeling

    DOE PAGES

    Carvajal-Nunez, U.; Elbakhshwan, M. S.; Mara, N. A.; ...

    2017-12-04

    Three methods were used to measure the mechanical properties of U 3Si, U 3Si 2, and USi. Quasi-static and continuous stiffness measurement nanoindentation were used to determine hardness and Young’s modulus, and microindentation was used to evaluate the bulk hardness. Hardness and Young’s modulus of the three U-Si compounds were both observed to increase with Si content. In conclusion, finite elements modelling was used to validate the nanoindentation data calculated for U 3Si 2 and estimate its yield strength.

  9. Spherical nanoindentation stress-strain curves of commercially pure titanium and Ti-6Al-4V

    DOE Data Explorer

    Weaver, Jordan S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Priddy, Matthew W. [Georgia Inst. of Technology, Atlanta, GA (United States); McDowell, David L. [Georgia Inst. of Technology, Atlanta, GA (United States); Kalidindi, Surya R. [Georgia Inst. of Technology, Atlanta, GA (United States)

    2016-07-27

    Spherical nanoindentation combined with electron back-scattered diffraction was employed to characterize the grain-scale elastic and plastic anisotropy of single crystal alpha-Ti for commercially pure (CP-Ti) and alloyed (Ti-64) titanium. In addition, alpha-beta Ti (single colony) grains were characterized. The data set includes the nanoindentation force, displacement, and contact stiffness, the nanoindentation stress-strain analysis, and the alpha-Ti crystal orientations. Details of the samples and experimental protocols can be found in Weaver et al. (2016) Acta Materialia doi:10.1016/j.actamat.2016.06.053.

  10. Methodologies in determining mechanical properties of thin films using nanoindentation

    NASA Astrophysics Data System (ADS)

    Han, Seung Min Jane

    Thin films are critical components of microelectronic and MEMS devices, and evaluating their mechanical properties is of current interest. As the dimensions of the devices become smaller and smaller, however, understanding the mechanical properties of materials at sub-micron length scales becomes more challenging. The conventional methods for evaluating strengths of materials in bulk form cannot be applied, and new methodologies are required for accurately evaluating mechanical properties of thin films. In this work, development of methodologies using the nanoindenter was pursued in three parts: (1) creation of a new method for extracting thin film hardness, (2) use of combinatorial methods for determining compositions with desired mechanical properties, and (3) use of microcompression testing of sub-micron sized pillars to understand plasticity in Al-Sc multilayers. The existing nanoindentation hardness model by Oliver & Pharr is unable to accurately determine the hardness of thin films on substrates with an elastic mismatch. Thus, a new method of analysis for extracting thin film hardness from film/substrate systems, that eliminates the effect of elastic mismatch of the underlying substrate, surface roughness, and also pile-up/sink-in, is needed. Such a method was developed in the first part of this study. The feasibility of using the nanoindentation hardness together with combinatorial methods to efficiently scan through mechanical properties of Ti-Al metallic alloys was examined in the second part of this study. The combinatorial approach provides an efficient method that can be used to determine alloy compositions that might merit further exploration and development as bulk materials. Finally, the mechanical properties of Al-Al3Sc multilayers with bilayer periods ranging from 6-100 nm were examined using microcompression. The sub-micron sized pillars were prepared using the focused ion beam (FIB) and compression tested with the flat tip of the nanoindenter

  11. Gas permeation measurements on small polymer specimens

    NASA Technical Reports Server (NTRS)

    Burns, Karen S.; Vannorman, John D.

    1988-01-01

    Mass spectrometry was used to measure oxygen and nitrogen permeabilities while polarography was used to measure oxygen permeabilities for several contact lens materials. Applicable sample holders were designed and fabricated to accommodate curved and flat specimens. A prepared standard was used to calibrate the mass spectrometric analyses. The oxygen permeability values determined by mass spectrometry were significantly greater than those determined by polarography. This was attributed to the phase boundary phenomena and the limiting oxygen permeance of water inherent in the polarographic technique. Polarographic values determined were in good agreement with proprietary values obtained by polarography, with the exception of one material.

  12. Diabetes management in Commercial Driver License holders.

    PubMed

    Kerr, Jessica L; Frichtl, Kelsey D; Behnen, Erin M

    2015-04-01

    The purpose of this study is to evaluate diabetes management in Commercial Driver License (CDL) holders, how prescribing habits change when treating this patient population, and health care providers' knowledge of regulations concerning insulin use in CDL holders. A survey was posted on the American Association of Diabetes Educators (AADE) Communities of Interest websites and was open for 2 weeks. The anonymous survey collected demographic data and evaluated the perspectives of health care providers on diabetes management in CDL holders. Descriptive statistics were used to analyze the survey results. A total of 139 AADE members responded to the survey, and 22.2% were prescribing providers. Findings from the survey indicated an overall lack of knowledge by health care professionals regarding the current laws affecting diabetes management in CDL holders. Most participants emphasized the need for making decisions on CDL suspension on a case-by-case basis, and some expressed concern that current laws may not be appropriate. Additional diabetes education for health care providers who treat CDL holders is warranted as many health care providers were not familiar with current regulations and management strategies. © 2015 The Author(s).

  13. A microelectromechanical systems (MEMS) force-displacement transducer for sub-5 nm nanoindentation and adhesion measurements

    NASA Astrophysics Data System (ADS)

    Zhang, Youfeng; Oh, Yunje; Stauffer, Douglas; Polycarpou, Andreas A.

    2018-04-01

    We present a highly sensitive force-displacement transducer capable of performing ultra-shallow nanoindentation and adhesion measurements. The transducer utilizes electrostatic actuation and capacitive sensing combined with microelectromechanical fabrication technologies. Air indentation experiments report a root-mean-square (RMS) force resolution of 1.8 nN and an RMS displacement resolution of 0.019 nm. Nanoindentation experiments on a standard fused quartz sample report a practical RMS force resolution of 5 nN and an RMS displacement resolution of 0.05 nm at sub-10 nm indentation depths, indicating that the system has a very low system noise for indentation experiments. The high sensitivity and low noise enables the transducer to obtain high-resolution nanoindentation data at sub-5 nm contact depths. The sensitive force transducer is used to successfully perform nanoindentation measurements on a 14 nm thin film. Adhesion measurements were also performed, clearly capturing the pull-on and pull-off forces during approach and separation of two contacting surfaces.

  14. 49 CFR 192.175 - Pipe-type and bottle-type holders.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Pipe-type and bottle-type holders. 192.175 Section....175 Pipe-type and bottle-type holders. (a) Each pipe-type and bottle-type holder must be designed so... equipment, that might cause corrosion or interfere with the safe operation of the holder. (b) Each pipe-type...

  15. 49 CFR 192.175 - Pipe-type and bottle-type holders.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Pipe-type and bottle-type holders. 192.175 Section....175 Pipe-type and bottle-type holders. (a) Each pipe-type and bottle-type holder must be designed so... equipment, that might cause corrosion or interfere with the safe operation of the holder. (b) Each pipe-type...

  16. Utility of a Newly Designed Film Holder for Premolar Bitewing Radiography.

    PubMed

    Safi, Yaser; Esmaeelinejad, Mohammad; Vasegh, Zahra; Valizadeh, Solmaz; Aghdasi, Mohammad Mehdi; Sarani, Omid; Afsahi, Mahmoud

    2015-11-01

    Bitewing radiography is a valuable technique for assessment of proximal caries, alveolar crest and periodontal status. Technical errors during radiography result in erroneous radiographic interpretation, misdiagnosis, possible mistreatment or unnecessary exposure of patient for taking a repeat radiograph. In this study, we aimed to evaluate the efficacy of a film holder modified from the conventional one and compared it with that of conventional film holder. Our study population comprised of 70 patients who were referred to the Radiology Department for bilateral premolar bitewing radiographs as requested by their attending clinician. Bitewing radiographs in each patient were taken using the newly designed holder in one side and the conventional holder in the other side. The acceptability of the two holders from the perspectives of the technician and patients was determined using a 0-20 point scale. The frequency of overlap and film positioning errors was calculated for each method. The conventional holder had greater acceptability among patients compared to the newly designed holder (mean score of 16.59 versus 13.37). From the technicians' point of view, the newly designed holder was superior to the conventional holder (mean score of 17.33 versus 16.44). The frequency of overlap was lower using the newly designed holder (p<0.001) and it allowed more accurate film positioning (p=0.005). The newly designed holder may facilitate the process of radiography for technicians and may be associated with less frequency of radiographic errors compared to the conventional holder.

  17. Acceptance Testing of Thermoluminescent Dosimeter Holders.

    PubMed

    Romanyukha, Alexander; Grypp, Matthew D; Sharp, Thad J; DiRito, John N; Nelson, Martin E; Mavrogianis, Stanley T; Torres, Jeancarlo; Benevides, Luis A

    2018-05-01

    The U.S. Navy uses the Harshaw 8840/8841 dosimetric (DT-702/PD) system, which employs LiF:Mg,Cu,P thermoluminescent dosimeters (TLDs), developed and produced by Thermo Fisher Scientific (TFS). The dosimeter consists of four LiF:Mg,Cu,P elements, mounted in Teflon® on an aluminum card and placed in a plastic holder. The holder contains a unique filter for each chip made of copper, acrylonitrile butadiene styrene (ABS), Mylar®, and tin. For accredited dosimetry labs, the ISO/IEC 17025:2005(E) requires an acceptance procedure for all new equipment. The Naval Dosimetry Center (NDC) has developed and tested a new non-destructive procedure, which enables the verification and the evaluation of embedded filters in the holders. Testing is based on attenuation measurements of low-energy radiation transmitted through each filter in a representative sample group of holders to verify that the correct filter type and thickness are present. The measured response ratios are then compared with the expected response ratios. In addition, each element's measured response is compared to the mean response of the group. The test was designed and tested to identify significant nonconformities, such as missing copper or tin filters, double copper or double tin filters, or other nonconformities that may impact TLD response ratios. During the implementation of the developed procedure, testing revealed a holder with a double copper filter. To complete the evaluation, the impact of the nonconformities on proficiency testing was examined. The evaluation revealed failures in proficiency testing categories III and IV when these dosimeters were irradiated to high-energy betas.

  18. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures. (b...

  19. 21 CFR 892.1920 - Radiographic head holder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic head holder. 892.1920 Section 892.1920 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1920 Radiographic head holder. (a...

  20. Mechanical Characterization of Nanoporous Thin Films by Nanoindentation and Laser-induced Surface Acoustic Waves

    NASA Astrophysics Data System (ADS)

    Chow, Gabriel

    Thin films represent a critical sector of modern engineering that strives to produce functional coatings at the smallest possible length scales. They appear most commonly in semiconductors where they form the foundation of all electronic circuits, but exist in many other areas to provide mechanical, electrical, chemical, and optical properties. The mechanical characterization of thin films has been a continued challenge due foremost to the length scales involved. However, emerging thin films focusing on materials with significant porosity, complex morphologies, and nanostructured surfaces produce additional difficulties towards mechanical analysis. Nanoindentation has been the dominant thin film mechanical characterization technique for the last decade because of the quick results, wide range of sample applicability, and ease of sample preparation. However, the traditional nanoindentation technique encounters difficulties for thin porous films. For such materials, alternative means of analysis are desirable and the lesser known laser-induced surface acoustic wave technique (LiSAW) shows great potential in this area. This dissertation focuses on studying thin, porous, and nanostructured films by nanoindentation and LiSAW techniques in an effort to directly correlate the two methodologies and to test the limits and applicabilities of each technique on challenging media. The LiSAW technique is particularly useful for thin porous films because unlike indentation, the substrate is properly accounted for in the wave motion analysis and no plastic deformation is necessary. Additionally, the use of lasers for surface acoustic wave generation and detection allows the technique to be fully non-contact. This is desirable in the measurement of thin, delicate, and porous films where physical sample probing may not be feasible. The LiSAW technique is also valuable in overcoming nanoscale roughness, particularly for films that cannot be mechanically polished, since typical SAW

  1. Broadband nanoindentation of glassy polymers: Part II. Viscoplasticity

    Treesearch

    Joseph E. Jakes; Rod S. Lakes; Don S. Stone

    2012-01-01

    The relationship between hardness and flow stress in glassy polymers is examined. Materials studied include poly(methylmethacrylate), polystyrene, and polycarbonate. Properties are strongly rate dependent, so broadband nanoindentation creep (BNC) is used to measure hardness across a broad range of indentation strain rates (10-4 to 10 s

  2. 21 CFR 872.1905 - Dental x-ray film holder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental x-ray film holder. 872.1905 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1905 Dental x-ray film holder. (a) Identification. A dental x-ray film holder is a device intended to position and to hold x-ray film inside the mouth...

  3. 21 CFR 872.1905 - Dental x-ray film holder.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental x-ray film holder. 872.1905 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1905 Dental x-ray film holder. (a) Identification. A dental x-ray film holder is a device intended to position and to hold x-ray film inside the mouth...

  4. 21 CFR 872.1905 - Dental x-ray film holder.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental x-ray film holder. 872.1905 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1905 Dental x-ray film holder. (a) Identification. A dental x-ray film holder is a device intended to position and to hold x-ray film inside the mouth...

  5. 21 CFR 872.1905 - Dental x-ray film holder.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental x-ray film holder. 872.1905 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1905 Dental x-ray film holder. (a) Identification. A dental x-ray film holder is a device intended to position and to hold x-ray film inside the mouth...

  6. 21 CFR 872.1905 - Dental x-ray film holder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental x-ray film holder. 872.1905 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1905 Dental x-ray film holder. (a) Identification. A dental x-ray film holder is a device intended to position and to hold x-ray film inside the mouth...

  7. Ergonomic design and evaluation of a diagnostic ultrasound transducer holder.

    PubMed

    Ghasemi, Mohamad Sadegh; Hosseinzadeh, Payam; Zamani, Farhad; Ahmadpoor, Hossein; Dehghan, Naser

    2017-12-01

    Work-related musculoskeletal disorders (WMSDs) are injuries and disorders that affect the body's movement and musculoskeletal system. Awkward postures represent one of the major ergonomic risk factors that cause WMSDs among sonographers while working with an ultrasound transducer. This study aimed to design and evaluate a new holder for the ultrasound transducer. In the first phase a new holder was designed for the transducer, considering design principles. Evaluation of the new holder was then carried out by electrogoniometry and a locally perceived discomfort (LPD) scale. The application of design principles to the new holder resulted in an improvement of wrist posture and comfort. Wrist angles in extension, flexion, radial deviation and ulnar deviation were lower with utilization of the new holder. The severity of discomfort based on the LPD method in the two modes of work with and without the new holder was reported with values of 1.3 and 1.8, respectively (p < 0.05). Overall, this study indicated that applying ergonomics design principles was effective in minimizing wrist deviation and increasing comfort while working with the new holder.

  8. Experimental determination of micromachined discrete and continuous device spring constants using nanoindentation method

    NASA Astrophysics Data System (ADS)

    Chan, M. L.; Tay, Francis E.; Logeeswaran, V. J.; Zeng, Kaiyang; Shen, Lu; Chau, Fook S.

    2002-04-01

    A rapid and accurate static and quasi-static method for determining the out-of-plane spring constraints of cantilevers and a micromachined vibratory sensor is presented. In the past, much of the effort in nanoindentation application was to investigate the thin-film mechanical properties. In this paper, we have utilized the nanoindentation method to measure directly some micromachined device (e.g. microgyroscope) spring constants. The cantilevers and devices tested were fabricated using the MUMPS process and an SOI process (patent pending). Spring constants are determined using a commercial nanoindentation apparatus UMIS-2000 configured with both Berkovich and spherical indenter tip that can be placed onto the device with high accuracy. Typical load resolution is 20micrometers N to 0.5N and a displacement resolution of 0.05nm. Information was deduced from the penetration depth versus load curves during both loading and unloading.

  9. Broadband nanoindentation of glassy polymers: Part I Viscoelasticity

    Treesearch

    Joesph E. Jakes; Rod S. Lakes; Don S. Stone

    2012-01-01

    Protocols are developed to assess viscoelastic moduli from unloading slopes in Berkovich nanoindentation across four orders of magnitude in time scale (0.01-100 s unloading time). Measured viscoelastic moduli of glassy polymers poly(methyl methacrylate), polystyrene, and polycarbonate follow the same trends with frequency (1/unloading time) as viscoelastic moduli...

  10. Elastic properties of single-walled carbon nanotube thin film by nanoindentation test.

    PubMed

    Tang, Xingling; El-Hami, Abdelkhalak; El-Hami, Khalil; Eid, Mohamed; Si, Chaorun

    2017-09-12

    This paper carries out a preliminary study for the elastic properties of single walled carbon nanotube (SWCNT) thin film. The SWCNT thin films (~250 nm) are prepared by a simple and cost effective method of spin-coating technology. Nanoindentation test with a Berkovich indenter is used to determine the hardness and elastic modulus of the SWCNT thin film. It is important to note that the elastic properties of SWCNT film are indirectly derived from the information of load and displacement of the indenter under certain assumptions, deviation of the 'test value' is inevitable. In this regard, uncertainty analysis is an effective process in guarantying the validity of the material properties. This paper carries out uncertainty estimation for the tested elastic properties of SWCNT film by nanoindentation. Experimental results and uncertainty analysis indicates that nanoindentation test could be an effective and reliable method in determine the elastic properties of SWCNT thin film. Moreover, the obtained values of hardness and elastic modulus can further benefit the design of SWCNT thin film based components.

  11. 12 CFR 569.3 - Holders of proxies.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Holders of proxies. 569.3 Section 569.3 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY PROXIES § 569.3 Holders of proxies. No proxy of a mutual savings association with a term greater than eleven months or solicited at...

  12. The Physical Mechanism of Frictional Aging Revealed by Nanoindentation Creep

    NASA Astrophysics Data System (ADS)

    Thom, C.; Carpick, R. W.; Goldsby, D. L.

    2017-12-01

    A classical observation from rock friction experiments is that friction increases linearly with the logarithm of the time of stationary contact, a phenomenon sometimes referred to as aging. Aging is most often attributed to an increase in the real area of contact due to asperity creep. However, recent atomic force microscopy (AFM) experiments and molecular dynamics simulations suggest that time-dependent siloxane (Si—O—Si) bonding gives rise to aging in silica-silica contacts in the absence of plastic deformation. Determining whether an increase in contact `quantity' (due to creep), contact `quality' (due to chemical bonding), or another unknown mechanism causes aging is a challenging experimental task, despite its importance for developing a physical basis for rate and state friction laws. An intriguing observation is that aging is absent in friction experiments on quartz rocks and gouge at humidities <5% and returns upon exposure of the test specimens to humid air. This behavior has been attributed to the effects of water on asperity creep (via hydrolytic weakening) or on the adhesive strength of contacts. To discern between these possibilities, we have conducted nanoindentation experiments on single crystals of quartz to measure their indentation hardness and creep behavior at humidities of 2% to 50%, and in vacuum. Samples were loaded at 1000 mN/s to a peak load of 15, 40, or 400 mN, which was then held constant for 10 s. After the peak load is reached, the tip sinks into the material with time due to creep of the indentation contact. Our experiments reveal that there is no effect of varying humidity on either indentation hardness or indentation creep behavior over the full range of humidities investigated. If asperity creep were the dominant mechanism of frictional aging for quartz in the experiments cited above, then significant increases in hardness and decreases in the growth rate of indentation contacts at low humidities is expected, in stark contrast

  13. Lexan Linear Shaped Charge Holder with Magnets and Backing Plate

    NASA Technical Reports Server (NTRS)

    Maples, Matthew W.; Dutton, Maureen L.; Hacker, Scott C.; Dean, Richard J.; Kidd, Nicholas; Long, Chris; Hicks, Robert C.

    2013-01-01

    A method was developed for cutting a fabric structural member in an inflatable module, without damaging the internal structure of the module, using linear shaped charge. Lexan and magnets are used in a charge holder to precisely position the linear shaped charge over the desired cut area. Two types of charge holders have been designed, each with its own backing plate. One holder cuts fabric straps in the vertical configuration, and the other charge holder cuts fabric straps in the horizontal configuration.

  14. 7 CFR 4279.78 - Repurchase from holder.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... repurchase, less the lender's servicing fee, within 30 days after written demand to the Agency from the... portion of the loan from a holder within 30 days of written demand by the holder when the borrower is in default not less than 60 days on principal or interest due on the loan; or the lender has failed to remit...

  15. 7 CFR 4279.78 - Repurchase from holder.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... repurchase, less the lender's servicing fee, within 30 days after written demand to the Agency from the... portion of the loan from a holder within 30 days of written demand by the holder when the borrower is in default not less than 60 days on principal or interest due on the loan; or the lender has failed to remit...

  16. Plasticity performance of Al 0.5 CoCrCuFeNi high-entropy alloys under nanoindentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Li-ping; Chen, Shu-ying; Ren, Jing-li

    2017-04-01

    The statistical and dynamic behaviors of the displacement-load curves of a high-entropy alloy, Al0.5 CoCrCuFeNi, were analyzed for the nanoindentation performed at two temperatures. Critical behavior of serrations at room temperature and chaotic flows at 200 °C were detected. These results are attributed to the interaction among a large number of slip bands. For the nanoindentation at room temperature, recurrent partial events between slip bands introduce a hierarchy of length scales, leading to a critical state. For the nanoindentation at 200 °C, there is no spatial interference between two slip bands, which is corresponding to the evolution of separated trajectorymore » of chaotic behavior« less

  17. Characterisation of Asphalt Concrete Using Nanoindentation

    PubMed Central

    Barbhuiya, Salim; Caracciolo, Benjamin

    2017-01-01

    In this study, nanoindentation was conducted to extract the load-displacement behaviour and the nanomechanical properties of asphalt concrete across the mastic, matrix, and aggregate phases. Further, the performance of hydrated lime as an additive was assessed across the three phases. The hydrated lime containing samples have greater resistance to deformation in the mastic and matrix phases, in particular, the mastic. There is strong evidence suggesting that hydrated lime has the most potent effect on the mastic phase, with significant increase in hardness and stiffness. PMID:28773181

  18. Loading simulation of lumbar spine vertebrae during a compression test using the finite elements method and trabecular bone strength properties, determined by means of nanoindentations.

    PubMed

    Bouzakis, K D; Mitsi, S; Michailidis, N; Mirisidis, I; Mesomeris, G; Maliaris, G; Korlos, A; Kapetanos, G; Antonarakos, P; Anagnostidis, K

    2004-06-01

    The mechanical strength properties of lumbar spine vertebrae are of great importance in a wide range of applications. Herein, through nanoindentations and appropriate evaluation of the corresponding results, trabecular bone struts stress-strain characteristics can be determined. In the frame of the present paper, an L2 fresh cadaveric vertebra, from which posterior elements were removed, was subjected to compression. With the aid of developed finite elements method based algorithms, the cortical shell and the cancellous core bulk elasticity moduli and stresses were determined, whereas the tested vertebra geometrical model used in these algorithms was considered as having a compound structure, consisting of the cancellous bone surrounded by the cortical shell. Moreover nanoindentations were conducted and an appropriate evaluation method of the obtained results was applied to extract stress-strain curves of individual lumbar spine vertebra trabecular bone struts. These data were used in the mathematical description of the vertebrae compression test. The vertebral cancellous bone structure was simulated by a beam elements network, possessing an equivalent porosity and different stiffnesses in vertical and horizontal direction. Thus, the measured course of the compression load versus the occurring specimen deformation was verified.

  19. Hierarchical structure observation and nanoindentation size effect characterization for a limnetic shell

    NASA Astrophysics Data System (ADS)

    Song, Jingru; Fan, Cuncai; Ma, Hansong; Wei, Yueguang

    2015-06-01

    In the present research, hierarchical structure observation and mechanical property characterization for a type of biomaterial are carried out. The investigated biomaterial is Hyriopsis cumingii, a typical limnetic shell, which consists of two different structural layers, a prismatic "pillar" structure and a nacreous "brick and mortar" structure. The prismatic layer looks like a "pillar forest" with variation-section pillars sized on the order of several tens of microns. The nacreous material looks like a "brick wall" with bricks sized on the order of several microns. Both pillars and bricks are composed of nanoparticles. The mechanical properties of the hierarchical biomaterial are measured by using the nanoindentation test. Hardness and modulus are measured for both the nacre layer and the prismatic layer, respectively. The nanoindentation size effects for the hierarchical structural materials are investigated experimentally. The results show that the prismatic nanostructured material has a higher stiffness and hardness than the nacre nanostructured material. In addition, the nanoindentation size effects for the hierarchical structural materials are described theoretically, by using the trans-scale mechanics theory considering both strain gradient effect and the surface/interface effect. The modeling results are consistent with experimental ones.

  20. Berkovich Nanoindentation on AlN Thin Films

    PubMed Central

    2010-01-01

    Berkovich nanoindentation-induced mechanical deformation mechanisms of AlN thin films have been investigated by using atomic force microscopy (AFM) and cross-sectional transmission electron microscopy (XTEM) techniques. AlN thin films are deposited on the metal-organic chemical-vapor deposition (MOCVD) derived Si-doped (2 × 1017 cm−3) GaN template by using the helicon sputtering system. The XTEM samples were prepared by means of focused ion beam (FIB) milling to accurately position the cross-section of the nanoindented area. The hardness and Young’s modulus of AlN thin films were measured by a Berkovich nanoindenter operated with the continuous contact stiffness measurements (CSM) option. The obtained values of the hardness and Young’s modulus are 22 and 332 GPa, respectively. The XTEM images taken in the vicinity regions just underneath the indenter tip revealed that the multiple “pop-ins” observed in the load–displacement curve during loading are due primarily to the activities of dislocation nucleation and propagation. The absence of discontinuities in the unloading segments of load–displacement curve suggests that no pressure-induced phase transition was involved. Results obtained in this study may also have technological implications for estimating possible mechanical damages induced by the fabrication processes of making the AlN-based devices. PMID:20672096

  1. Berkovich Nanoindentation on AlN Thin Films.

    PubMed

    Jian, Sheng-Rui; Chen, Guo-Ju; Lin, Ting-Chun

    2010-03-31

    Berkovich nanoindentation-induced mechanical deformation mechanisms of AlN thin films have been investigated by using atomic force microscopy (AFM) and cross-sectional transmission electron microscopy (XTEM) techniques. AlN thin films are deposited on the metal-organic chemical-vapor deposition (MOCVD) derived Si-doped (2 × 1017 cm-3) GaN template by using the helicon sputtering system. The XTEM samples were prepared by means of focused ion beam (FIB) milling to accurately position the cross-section of the nanoindented area. The hardness and Young's modulus of AlN thin films were measured by a Berkovich nanoindenter operated with the continuous contact stiffness measurements (CSM) option. The obtained values of the hardness and Young's modulus are 22 and 332 GPa, respectively. The XTEM images taken in the vicinity regions just underneath the indenter tip revealed that the multiple "pop-ins" observed in the load-displacement curve during loading are due primarily to the activities of dislocation nucleation and propagation. The absence of discontinuities in the unloading segments of load-displacement curve suggests that no pressure-induced phase transition was involved. Results obtained in this study may also have technological implications for estimating possible mechanical damages induced by the fabrication processes of making the AlN-based devices.

  2. Direct comparison of nanoindentation and tensile test results on reactor-irradiated materials

    DOE PAGES

    Krumweide, David L; Yamamoto, Takuya; Saleh, Tarik A.; ...

    2018-03-13

    Nanoindentation testing has been used for decades to assess materials on a local scale and to obtain fundamental mechanical property parameters. Nuclear materials research often faces the challenge of testing rather small samples due to the hazardous nature, limited space in reactors, and shallow ion-irradiated zones, fostering the need for small-scale mechanical testing (SSMT). As such, correlating the results from SSMT to bulk properties is particularly of interest. Here, this study compares macroscopic tensile test data (yield and flow stresses) to nanoindentation data (hardness) obtained on a number of different neutron-irradiated materials in order to understand the scaling behavior onmore » radiation-damaged samples.« less

  3. Direct comparison of nanoindentation and tensile test results on reactor-irradiated materials

    NASA Astrophysics Data System (ADS)

    Krumwiede, D. L.; Yamamoto, T.; Saleh, T. A.; Maloy, S. A.; Odette, G. R.; Hosemann, P.

    2018-06-01

    Nanoindentation testing has been used for decades to assess materials on a local scale and to obtain fundamental mechanical property parameters. Nuclear materials research often faces the challenge of testing rather small samples due to the hazardous nature, limited space in reactors, and shallow ion-irradiated zones, fostering the need for small-scale mechanical testing (SSMT). As such, correlating the results from SSMT to bulk properties is particularly of interest. This study compares macroscopic tensile test data (yield and flow stresses) to nanoindentation data (hardness) obtained on a number of different neutron-irradiated materials in order to understand the scaling behavior on radiation-damaged samples.

  4. Direct comparison of nanoindentation and tensile test results on reactor-irradiated materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krumweide, David L; Yamamoto, Takuya; Saleh, Tarik A.

    Nanoindentation testing has been used for decades to assess materials on a local scale and to obtain fundamental mechanical property parameters. Nuclear materials research often faces the challenge of testing rather small samples due to the hazardous nature, limited space in reactors, and shallow ion-irradiated zones, fostering the need for small-scale mechanical testing (SSMT). As such, correlating the results from SSMT to bulk properties is particularly of interest. Here, this study compares macroscopic tensile test data (yield and flow stresses) to nanoindentation data (hardness) obtained on a number of different neutron-irradiated materials in order to understand the scaling behavior onmore » radiation-damaged samples.« less

  5. Biological and nano-indentation properties of polybenzoxazine-based composites reinforced with zirconia particles as a novel biomaterial.

    PubMed

    Lotfi, L; Javadpour, J; Naimi-Jamal, M R

    2018-01-01

    The biological and mechanical properties of substances are relevant to their application as biomaterials and there are many efforts to enhance biocompatibility and mechanical properties of bio-medical materials. In this study, to achieve a low rate of shrinkage during polymerization, good mechanical properties, and excellent biocompatibility, benzoxazine based composites were synthesized. Benzoxazine monomer was synthesized using a solventless method. FTIR and DSC analysis were carried out to determine the appropriate polymerization temperature. The low viscosity of the benzoxazine monomer at 70°C attract us to use in situ polymerization after high speed ball milling of the benzoxazine and it mixture with different weight fractions of zirconia particles. Dispersion and adhesion between the ceramic and polymer components were evaluate by SEM. To evaluate the biological properties and toxicity of the polybenzoxazine-based composite samples reinforced with zirconia particles, 3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide assay was conducted. The micromechanical properties of each composite were evaluated by more than 20 nanoindentation tests and 3 nanoscratching tests. Surface topography of scratched regions was investigated using Atomic Force Microscopy. Shrinkage was simulated by Materials Studio software. SEM images showed good dispersion and adhesion between the ceramic and polymer components. Biocompatibility assay showed excellent in vitro biocompatibility. Nano-indentation force-displacement curves showed matrix, reinforcement and interphase regions in specimens and excellent homogeneity in mechanical properties. The nanoindentation results showed that the addition of zirconia particles to the polybenzoxazine matrix increased the modulus and hardness of the neat polybenzoxazine; however, by adding more than an optimum level of reinforcement particles, the mechanical properties decreased due to the agglomeration of reinforcement particles and

  6. Mining planer with pivotal tool holder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braun, E.; Braun, G.

    1983-10-04

    A planer assembly is disclosed for winning minerals from a mineral face comprising, a planer guide member, at least two planers slidably engaged on the guide member for movement in a travel direction along the face, a hinge interconnecting the two planers for transferring rotational moment applied to the planers and a planer tool holder mounted on each planer which carries a tool. The planer tool holder is positionable at an angle to make a cut of a selected depth with the depth increasing from planer to planer in a direction opposite the travel direction.

  7. Filter holder assembly having extended collar spacer ring

    DOEpatents

    Alvin, Mary Anne; Bruck, Gerald J.

    2002-01-01

    A filter holder assembly is provided that utilizes a fail-safe regenerator unit with an annular spacer ring having an extended metal collar for containment and positioning of a compliant ceramic gasket used in the assembly. The filter holder assembly is disclosed for use with advanced composite, filament wound, and metal candle filters.

  8. Nanoindentation cannot accurately predict the tensile strength of graphene or other 2D materials

    NASA Astrophysics Data System (ADS)

    Han, Jihoon; Pugno, Nicola M.; Ryu, Seunghwa

    2015-09-01

    Due to the difficulty of performing uniaxial tensile testing, the strengths of graphene and its grain boundaries have been measured in experiments by nanoindentation testing. From a series of molecular dynamics simulations, we find that the strength measured in uniaxial simulation and the strength estimated from the nanoindentation fracture force can differ significantly. Fracture in tensile loading occurs simultaneously with the onset of crack nucleation near 5-7 defects, while the graphene sheets often sustain the indentation loads after the crack initiation because the sharply concentrated stress near the tip does not give rise to enough driving force for further crack propagation. Due to the concentrated stress, strength estimation is sensitive to the indenter tip position along the grain boundaries. Also, it approaches the strength of pristine graphene if the tip is located slightly away from the grain boundary line. Our findings reveal the limitations of nanoindentation testing in quantifying the strength of graphene, and show that the loading-mode-specific failure mechanism must be taken into account in designing reliable devices from graphene and other technologically important 2D materials.Due to the difficulty of performing uniaxial tensile testing, the strengths of graphene and its grain boundaries have been measured in experiments by nanoindentation testing. From a series of molecular dynamics simulations, we find that the strength measured in uniaxial simulation and the strength estimated from the nanoindentation fracture force can differ significantly. Fracture in tensile loading occurs simultaneously with the onset of crack nucleation near 5-7 defects, while the graphene sheets often sustain the indentation loads after the crack initiation because the sharply concentrated stress near the tip does not give rise to enough driving force for further crack propagation. Due to the concentrated stress, strength estimation is sensitive to the indenter tip

  9. 10 CFR 1016.5 - Submission of procedures by access permit holder.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Submission of procedures by access permit holder. 1016.5 Section 1016.5 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA General Provisions § 1016.5 Submission of procedures by access permit holder. No access permit holder shall have...

  10. 10 CFR 1016.5 - Submission of procedures by access permit holder.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Submission of procedures by access permit holder. 1016.5 Section 1016.5 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA General Provisions § 1016.5 Submission of procedures by access permit holder. No access permit holder shall have...

  11. Nanoindentation study of bulk zirconium hydrides at elevated temperatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cinbiz, Mahmut Nedim; Balooch, Mehdi; Hu, Xunxiang

    Here, the mechanical properties of zirconium hydrides was studied using nano-indentation technique at a temperature range of 25 – 400 °C. Temperature dependency of reduced elastic modulus and hardness of δ- and ε-zirconium hydrides were obtained by conducting nanoindentation experiments on the bulk hydride samples with independently heating capability of indenter and heating stage. The reduced elastic modulus of δ-zirconium hydride (H/Zr ratio =1.61) decreased from ~113 GPa to ~109 GPa while temperature increased from room temperature to 400°C. For ε-zirconium hydrides (H/Zr ratio=1.79), the reduced elastic modulus decreased from 61 GPa to 54 GPa as temperature increased from roommore » temperature to 300 °C. Whereas, hardness of δ-zirconium hydride significantly decreased from 4.1 GPa to 2.41 GPa when temperature increased from room temperature to 400 °C. Similarly, hardness of ε-zirconium hydride decreased from 3.06 GPa to 2.19 GPa with temperature increase from room temperature to 300°C.« less

  12. Nanoindentation study of bulk zirconium hydrides at elevated temperatures

    DOE PAGES

    Cinbiz, Mahmut Nedim; Balooch, Mehdi; Hu, Xunxiang; ...

    2017-08-02

    Here, the mechanical properties of zirconium hydrides was studied using nano-indentation technique at a temperature range of 25 – 400 °C. Temperature dependency of reduced elastic modulus and hardness of δ- and ε-zirconium hydrides were obtained by conducting nanoindentation experiments on the bulk hydride samples with independently heating capability of indenter and heating stage. The reduced elastic modulus of δ-zirconium hydride (H/Zr ratio =1.61) decreased from ~113 GPa to ~109 GPa while temperature increased from room temperature to 400°C. For ε-zirconium hydrides (H/Zr ratio=1.79), the reduced elastic modulus decreased from 61 GPa to 54 GPa as temperature increased from roommore » temperature to 300 °C. Whereas, hardness of δ-zirconium hydride significantly decreased from 4.1 GPa to 2.41 GPa when temperature increased from room temperature to 400 °C. Similarly, hardness of ε-zirconium hydride decreased from 3.06 GPa to 2.19 GPa with temperature increase from room temperature to 300°C.« less

  13. 14 CFR 26.45 - Holders of type certificates-Alterations and repairs to alterations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRPLANES Aging Airplane Safety-Damage Tolerance Data for Repairs and Alterations § 26.45 Holders of type... alteration data developed by the holder of a type certificate, the holder must— (1) Review existing... Repairs Made to Alterations. For existing and future repair data developed by a holder of a type...

  14. 14 CFR 26.45 - Holders of type certificates-Alterations and repairs to alterations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AIRPLANES Aging Airplane Safety-Damage Tolerance Data for Repairs and Alterations § 26.45 Holders of type... alteration data developed by the holder of a type certificate, the holder must— (1) Review alteration data... Repairs Made to Alterations. For existing and future repair data developed by a holder of a type...

  15. 14 CFR 26.45 - Holders of type certificates-Alterations and repairs to alterations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AIRPLANES Aging Airplane Safety-Damage Tolerance Data for Repairs and Alterations § 26.45 Holders of type... alteration data developed by the holder of a type certificate, the holder must— (1) Review alteration data... Repairs Made to Alterations. For existing and future repair data developed by a holder of a type...

  16. 14 CFR 26.45 - Holders of type certificates-Alterations and repairs to alterations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AIRPLANES Aging Airplane Safety-Damage Tolerance Data for Repairs and Alterations § 26.45 Holders of type... alteration data developed by the holder of a type certificate, the holder must— (1) Review alteration data... Repairs Made to Alterations. For existing and future repair data developed by a holder of a type...

  17. A spectral approach for discrete dislocation dynamics simulations of nanoindentation

    NASA Astrophysics Data System (ADS)

    Bertin, Nicolas; Glavas, Vedran; Datta, Dibakar; Cai, Wei

    2018-07-01

    We present a spectral approach to perform nanoindentation simulations using three-dimensional nodal discrete dislocation dynamics. The method relies on a two step approach. First, the contact problem between an indenter of arbitrary shape and an isotropic elastic half-space is solved using a spectral iterative algorithm, and the contact pressure is fully determined on the half-space surface. The contact pressure is then used as a boundary condition of the spectral solver to determine the resulting stress field produced in the simulation volume. In both stages, the mechanical fields are decomposed into Fourier modes and are efficiently computed using fast Fourier transforms. To further improve the computational efficiency, the method is coupled with a subcycling integrator and a special approach is devised to approximate the displacement field associated with surface steps. As a benchmark, the method is used to compute the response of an elastic half-space using different types of indenter. An example of a dislocation dynamics nanoindentation simulation with complex initial microstructure is presented.

  18. Energy absorption characterization of human enamel using nanoindentation.

    PubMed

    He, Li Hong; Swain, Michael V

    2007-05-01

    Enamel is a natural composite, which has much higher toughness than its major component, crystalline hydroxyapatite. In this study, the energy absorption behavior of human sound enamel was investigated with nanoindentation techniques. A UMIS nanoindenter system as well as a Berkovich and two spherical indenters with nominal tip radii of 5 and 20 microm were used to indent enamel at different loading forces in the direction parallel to enamel prisms. Inelastic energy dissipation versus depth of indenter penetration (U%-h(p) curve) as well as a function of indentation strain (U%-epsilon curve) of enamel was determined. Enamel showed much higher energy absorption capacity than a ceramic material with equivalent modulus (fused silica). Even at the lowest forces (1 mN) for the 20 microm indenter, inelastic response was found. Additional tests done at different force loading rates illustrated that load rate has little influence on P-h response of enamel. The top surface of enamel has the plastic work of indentation of approximately 5.2 nJ/microm(3). The energy absorbing ability is influenced by the very small protein rich component that exists between the hydroxyapatite nanocrystals as well as within the sheath structure surrounding the enamel rods. Copyright 2006 Wiley Periodicals, Inc.

  19. Tool holder for preparation and inspection of a radiused edge cutting tool

    DOEpatents

    Asmanes, Charles

    1979-01-01

    A tool holding fixture is provided for removably holding a radiused edge cutting tool in a tool edge lapping apparatus. The fixture allows the operator to preset the lapping radius and angle before the tool holder is placed in the fixture and the holder may be removed from the lapping apparatus to inspect the tool and simply replaced in the fixture to continue lapping in accordance with a precise alignment without realignment of the tool relative to the lap. The tool holder includes a pair of self aligning bearings in the form of precision formed steel balls connected together by a rigid shaft. The tool is held by an arm extending from the shaft and the balls set in fixed position bearing cups and the holder is oscillated back and forth about a fixed axis of rotation to lap the tool radius by means of a reversibly driven belt-pulley arrangement coupled to the shaft between the bearings. To temporarily remove the holder, the drive belt is slipped over the rearward end of the holder and the holder is lifted out of the bearing cups.

  20. The Applications of Modern Nanoindentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Buskirk, Caleb Griffith

    2017-03-16

    The TI-950 TriboIndenter is a nanoindentation device that obtains nanometer resolution material topography images using Scanning Probe Microscopy (SPM), modulus maps of material using nano-Dynamic Mechanical Analysis, and provides hardness measurements with a resolution of 0.2 nm. The instrument applies a force to a material through a sharp tip and used a transducer to measure the force a material applies back to the tip to derive information about the material. The information can be used to study the homogeneity of material surfaces as well as the homogeneity of the material as a function of depth and can lead to importantmore » information on the aging of the material as well as the consistency of the production of the material.« less

  1. 49 CFR 192.177 - Additional provisions for bottle-type holders.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... performed on the holder after it has been heat treated or stress relieved, except that copper wires may be... produces a hoop stress at least equal to 85 percent of the SMYS. (5) The holder, connection pipe, and...

  2. 49 CFR 192.177 - Additional provisions for bottle-type holders.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... performed on the holder after it has been heat treated or stress relieved, except that copper wires may be... produces a hoop stress at least equal to 85 percent of the SMYS. (5) The holder, connection pipe, and...

  3. 49 CFR 192.177 - Additional provisions for bottle-type holders.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... performed on the holder after it has been heat treated or stress relieved, except that copper wires may be... produces a hoop stress at least equal to 85 percent of the SMYS. (5) The holder, connection pipe, and...

  4. Quick-Change Ceramic Flame Holder for High-Output Torches

    NASA Technical Reports Server (NTRS)

    Haskin, Henry

    2010-01-01

    Researchers at NASA's Langley Research Center have developed a new ceramic design flame holder with a service temperature of 4,000 F (2,204 C). The combination of high strength and high temperature capability, as well as a twist-lock mounting method to the steel burner, sets this flame holder apart from existing technology.

  5. 38 CFR 36.4341 - Death or insolvency of holder.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Death or insolvency of... Death or insolvency of holder. (a) Immediately upon the death of the holder and without the necessity of... expiration of charter, by forfeiture, or otherwise shall be treated as is the death of an individual as...

  6. 38 CFR 36.4341 - Death or insolvency of holder.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Death or insolvency of... Death or insolvency of holder. (a) Immediately upon the death of the holder and without the necessity of... expiration of charter, by forfeiture, or otherwise shall be treated as is the death of an individual as...

  7. 38 CFR 36.4341 - Death or insolvency of holder.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2014-07-01 2014-07-01 false Death or insolvency of... Death or insolvency of holder. (a) Immediately upon the death of the holder and without the necessity of... expiration of charter, by forfeiture, or otherwise shall be treated as is the death of an individual as...

  8. 38 CFR 36.4341 - Death or insolvency of holder.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2012-07-01 2012-07-01 false Death or insolvency of... Death or insolvency of holder. (a) Immediately upon the death of the holder and without the necessity of... expiration of charter, by forfeiture, or otherwise shall be treated as is the death of an individual as...

  9. 38 CFR 36.4341 - Death or insolvency of holder.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2013-07-01 2013-07-01 false Death or insolvency of... Death or insolvency of holder. (a) Immediately upon the death of the holder and without the necessity of... expiration of charter, by forfeiture, or otherwise shall be treated as is the death of an individual as...

  10. 30 CFR 250.1010 - General requirements for pipeline right-of-way holders.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... United States or its lessees or right-of-way holders, as the case may be, the full value of all damages...). The right-of-way holder shall make available all records relative to the design, construction... site. Furthermore, the holder is responsible for accidents or damages which might occur as a result of...

  11. Spherical Nanoindentation Stress-Strain Measurements of BOR-60 14YWT-NFA1 Irradiated Tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weaver, Jordan; Carvajal Nunez, Ursula; Krumwiede, David

    Spherical nanoindentation stress-strain protocols were applied to characterize unirradiated and fast neutron irradiated nanostructured ferritic alloy (NFA) 14YWT and compared against Berkovich nanohardness and available tensile data. The predicted uniaxial yield strength from spherical, 100 and 5 micron radii, indentation yield strength measurements was 1100-1400 MPa which compares well with the predictions from Berkovich nanohardness, 1200 MPa, and available tensile data, ~1100 MPa. However, spherical indentation measurements predict an increase in the uniaxial yield strength of ~1 GPa while Berkovich nanohardness measurements predict an increase of only ~250 MPa. No tensile data exists on the irradiated condition. It is believedmore » the difference in the predicted uniaxial yield strength between spherical and Berkovich nanoindentation are due to a low number of tests on the irradiated sample combined with the significant heterogeneity in the microstructure, the differences in sensitivity to sample preparation on the irradiated sample between the two indentation protocols , and/or in how strain localizes under the indenter with the possibility of dislocation channeling under Berkovich hardness indents leading to strain softening. Nanoindentation capabilities to test neutron irradiated samples in a radiological area were realized.« less

  12. Investigation of thermally activated deformation in amorphous PMMA and Zr-Cu-Al bulk metallic glasses with broadband nanoindentation creep

    Treesearch

    J.B. Puthoff; J.E. Jakes; H. Cao; D.S. Stone

    2009-01-01

    The development of nanoindentation test systems with high data collection speeds has made possible a novel type of indentation creep test: broadband nanoindentation creep (BNC). Using the high density of data points generated and analysis techniques that can model the instantaneous projected indent area at all times during a constant-load indentation experiment, BNC...

  13. Laser Plasma Soft X-ray Microscope with Wolter Mirrors for Observation of Biological Specimens in Air

    NASA Astrophysics Data System (ADS)

    Hoshino, Masato; Aoki, Sadao

    2006-02-01

    A laser plasma soft X-ray microscope with Wolter mirrors was developed so that specimens could be set in the atmosphere. Silicon nitride membranes 100 nm thick were used as vacuum-tight windows. Using relatively large windows (0.46× 0.46 mm2), an adequate working distance for samples, which was approximately 1.2 mm, was assured. The endurance of the vacuum-tight window was measured briefly. Dry biological cells could be observed with resolution better than 100 nm. A preliminary observation of wet biological cells was carried out using a wet environmental sample holder which was composed of only two sheets of silicon nitride membrane. An X-ray micrograph of wet red blood cells from a chicken was obtained without apparent effects of radiation damage. The properties of a vacuum-tight window and a wet sample holder are discussed.

  14. 75 FR 59711 - Audit Program for Texas Flexible Permit Holders

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-28

    ... ENVIRONMENTAL PROTECTION AGENCY [EPA-R06-OAR-2010-0510; FRL-9207-4] Audit Program for Texas... Act (CAA) voluntary audit compliance program for flexible permit holders in the State of Texas (hereinafter ``Audit Program''); response to public comments. SUMMARY: EPA is offering holders of Texas...

  15. Advanced Nanoindentation Testing for Studying Strain-Rate Sensitivity and Activation Volume

    NASA Astrophysics Data System (ADS)

    Maier-Kiener, Verena; Durst, Karsten

    2017-11-01

    Nanoindentation became a versatile tool for testing local mechanical properties beyond hardness and modulus. By adapting standard nanoindentation test methods, simple protocols capable of probing thermally activated deformation processes can be accomplished. Abrupt strain-rate changes within one indentation allow determining the strain-rate dependency of hardness at various indentation depths. For probing lower strain-rates and excluding thermal drift influences, long-term creep experiments can be performed by using the dynamic contact stiffness for determining the true contact area. From both procedures hardness and strain-rate, and consequently strain-rate sensitivity and activation volume can be reliably deducted within one indentation, permitting information on the locally acting thermally activated deformation mechanism. This review will first discuss various testing protocols including possible challenges and improvements. Second, it will focus on different examples showing the direct influence of crystal structure and/or microstructure on the underlying deformation behavior in pure and highly alloyed material systems.

  16. A Nanoindentation Study of the Plastic Deformation and Fracture Mechanisms in Single-Crystalline CaFe2As2

    NASA Astrophysics Data System (ADS)

    Frawley, Keara G.; Bakst, Ian; Sypek, John T.; Vijayan, Sriram; Weinberger, Christopher R.; Canfield, Paul C.; Aindow, Mark; Lee, Seok-Woo

    2018-04-01

    The plastic deformation and fracture mechanisms in single-crystalline CaFe2As2 has been studied using nanoindentation and density functional theory simulations. CaFe2As2 single crystals were grown in a Sn-flux, resulting in homogeneous and nearly defect-free crystals. Nanoindentation along the [001] direction produces strain bursts, radial cracking, and lateral cracking. Ideal cleavage simulations along the [001] and [100] directions using density functional theory calculations revealed that cleavage along the [001] direction requires a much lower stress than cleavage along the [100] direction. This strong anisotropy of cleavage strength implies that CaFe2As2 has an atomic-scale layered structure, which typically exhibits lateral cracking during nanoindentation. This special layered structure results from weak atomic bonding between the (001) Ca and Fe2As2 layers.

  17. System for loading slab-gel holders for electrophoresis separation

    DOEpatents

    Anderson, Norman G.; Anderson, Norman L.

    1979-01-01

    A slab-gel loading system includes a prismatic chamber for filling a plurality of slab-gel holders simultaneously. Each slab-gel holder comprises a pair of spaced apart plates defining an intermediate volume for gel containment. The holders are vertically positioned in the chamber with their major surfaces parallel to the chamber end walls. A liquid inlet is provided at the corner between the bottom and a side wall of the chamber for distributing a polymerizable monomer solution or a coagulable colloidal solution into each of the holders. The chamber is rotatably supported so that filling can begin with the corner having the liquid inlet directed downwardly such that the solution is gently funneled upwardly, without mixing, along the diverging side and bottom surfaces. As filling proceeds, the chamber is gradually rotated to position the bottom wall in a horizontal mode. The liquid filling means includes a plastic envelope with a septum dividing it into two compartments for intermixing two solutions of different density and thereby providing a liquid flow having a density gradient. The resulting gels have a density gradient between opposite edges for subsequent use in electrophoresis separations.

  18. 21 CFR 1311.20 - Coordinators for CSOS digital certificate holders.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Coordinators for CSOS digital certificate holders... REQUIREMENTS FOR ELECTRONIC ORDERS AND PRESCRIPTIONS (Eff. 6-1-10) Obtaining and Using Digital Certificates for Electronic Orders § 1311.20 Coordinators for CSOS digital certificate holders. (a) Each registrant...

  19. 32 CFR 767.9 - Content of permit holder's final report.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 5 2014-07-01 2014-07-01 false Content of permit holder's final report. 767.9 Section 767.9 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS... JURISDICATION OF THE DEPARTMENT OF THE NAVY Permit Guidelines § 767.9 Content of permit holder's final report...

  20. 32 CFR 767.9 - Content of permit holder's final report.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 5 2013-07-01 2013-07-01 false Content of permit holder's final report. 767.9 Section 767.9 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS... JURISDICATION OF THE DEPARTMENT OF THE NAVY Permit Guidelines § 767.9 Content of permit holder's final report...

  1. Nanoindentation and the micromechanics of Van Gogh oil paints

    NASA Astrophysics Data System (ADS)

    Salvant, Johanna; Barthel, Etienne; Menu, Michel

    2011-08-01

    Understanding the mechanical properties of ancient paintings is a major issue for conservation and restoration. One strategy is to measure the mechanical properties of reconstructed paints: however, the aging process is poorly known, so it is also desirable to measure mechanical properties directly on ancient paint samples. Using nanoindentation, we have characterized submillimetric samples recovered from restoration of two Van Gogh paintings and compared the results with reconstructed paint samples. We demonstrate that the reduced modulus and hardness of historical paints can be measured at a very local scale, even differentiating between each paint layer. Our reconstructed paint samples exhibit elastic moduli comparable to values of the literature, but the values measured on the two 19th century paint samples are found to be significantly larger. Similarly, the compositional dependence of the elastic modulus is consistent with literature results for our reconstructed samples while our preliminary results for ancient samples do not readily fall into the same pattern. These results all point out to a significant impact of long term aging, in a manner which is difficult to predict in our present state of understanding. They demonstrate that nanoindentation is a very adequate tool to improve our knowledge of art paint mechanics and aging.

  2. A Nanoindentation Study of the Plastic Deformation and Fracture Mechanisms in Single-Crystalline CaFe 2As 2

    DOE PAGES

    Frawley, Keara G.; Bakst, Ian; Sypek, John T.; ...

    2018-04-10

    In this paper, the plastic deformation and fracture mechanisms in single-crystalline CaFe 2As 2 has been studied using nanoindentation and density functional theory simulations. CaFe 2As 2 single crystals were grown in a Sn-flux, resulting in homogeneous and nearly defect-free crystals. Nanoindentation along the [001] direction produces strain bursts, radial cracking, and lateral cracking. Ideal cleavage simulations along the [001] and [100] directions using density functional theory calculations revealed that cleavage along the [001] direction requires a much lower stress than cleavage along the [100] direction. This strong anisotropy of cleavage strength implies that CaFe 2As 2 has an atomic-scalemore » layered structure, which typically exhibits lateral cracking during nanoindentation. This special layered structure results from weak atomic bonding between the (001) Ca and Fe 2As 2 layers.« less

  3. A Nanoindentation Study of the Plastic Deformation and Fracture Mechanisms in Single-Crystalline CaFe 2As 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frawley, Keara G.; Bakst, Ian; Sypek, John T.

    In this paper, the plastic deformation and fracture mechanisms in single-crystalline CaFe 2As 2 has been studied using nanoindentation and density functional theory simulations. CaFe 2As 2 single crystals were grown in a Sn-flux, resulting in homogeneous and nearly defect-free crystals. Nanoindentation along the [001] direction produces strain bursts, radial cracking, and lateral cracking. Ideal cleavage simulations along the [001] and [100] directions using density functional theory calculations revealed that cleavage along the [001] direction requires a much lower stress than cleavage along the [100] direction. This strong anisotropy of cleavage strength implies that CaFe 2As 2 has an atomic-scalemore » layered structure, which typically exhibits lateral cracking during nanoindentation. This special layered structure results from weak atomic bonding between the (001) Ca and Fe 2As 2 layers.« less

  4. Filter holder and gasket assembly for candle or tube filters

    DOEpatents

    Lippert, Thomas Edwin; Alvin, Mary Anne; Bruck, Gerald Joseph; Smeltzer, Eugene E.

    1999-03-02

    A filter holder and gasket assembly for holding a candle filter element within a hot gas cleanup system pressure vessel. The filter holder and gasket assembly includes a filter housing, an annular spacer ring securely attached within the filter housing, a gasket sock, a top gasket, a middle gasket and a cast nut.

  5. Correction of the post -- necking true stress -- strain data using instrumented nanoindentation

    NASA Astrophysics Data System (ADS)

    Romero Fonseca, Ivan Dario

    The study of large plastic deformations has been the focus of numerous studies particularly in the metal forming processes and fracture mechanics fields. A good understanding of the plastic flow properties of metallic alloys and the true stresses and true strains induced during plastic deformation is crucial to optimize the aforementioned processes, and to predict ductile failure in fracture mechanics analyzes. Knowledge of stresses and strains is extracted from the true stress-strain curve of the material from the uniaxial tensile test. In addition, stress triaxiality is manifested by the neck developed during the last stage of a tensile test performed on a ductile material. This necking phenomenon is the factor responsible for deviating from uniaxial state into a triaxial one, then, providing an inaccurate description of the material's behavior after the onset of necking. The research of this dissertation is aimed at the development of a correction method for the nonuniform plastic deformation (post-necking) portion of the true stress-strain curve. The correction proposed is based on the well-known relationship between hardness and flow (yield) stress, except that instrumented nanoindentation hardness is utilized rather than conventional macro or micro hardness. Three metals with different combinations of strain hardening behavior and crystal structure were subjected to quasi-static tensile tests: power-law strain hardening low carbon G10180 steel (BCC) and electrolytic tough pitch copper C11000 (FCC), and linear strain hardening austenitic stainless steel S30400 (FCC). Nanoindentation hardness values, measured on the broken tensile specimen, were converted into flow stress values by means of the constraint factor C from Tabor's, the representative plastic strainepsilonr and the post-test true plastic strains measured. Micro Vickers hardness testing was carried out on the sample as well. The constraint factors were 5.5, 4.5 and 4.5 and the representative plastic

  6. Nanoindentation study of interphases in epoxy/amine thermosetting systems modified with thermoplastics.

    PubMed

    Ramos, Jose Angel; Blanco, Miren; Zalakain, Iñaki; Mondragon, Iñaki

    2009-08-15

    The characterization of a mixture of epoxy/amine with different stoichiometric ratios was carried out by means of nanoindentation. The epoxy system was composed by diglycidyl ether of bisphenol-A and 4,4'-methylene bis-(3-chloro 2,6-diethylaniline). Diffusion through interface formed by epoxy/amine system in stoichiometric ratio and several thermoplastic polymers was also analyzed by means of stiffness analysis, as studied by atomic force microscopy (AFM) and coupled nanoindentation tests. Used thermoplastics were an amorphous, atactic polystyrene, and two semicrystalline, syndiotactic polystyrene and poly(phenylene sulfide). Larger range diffusion was obtained in epoxy/amine systems modified with atactic polystyrene while the study of the influence of stoichiometric ratio suggests that the excess of epoxy generated stiffer material. In addition, larger indentation loads resulted in higher apparent stiffness because of the more number of polymer chains that had to re-accommodate owing to the increase in contact area.

  7. The effect of grain orientation on nanoindentation behavior of model austenitic alloy Fe-20Cr-25Ni

    DOE PAGES

    Chen, Tianyi; Tan, Lizhen; Lu, Zizhe; ...

    2017-07-26

    Instrumented nanoindentation was used in this paper to investigate the hardness, elastic modulus, and creep behavior of an austenitic Fe-20Cr-25Ni model alloy at room temperature, with the indented grain orientation being the variant. The samples indented close to the {111} surfaces exhibited the highest hardness and modulus. However, nanoindentation creep tests showed the greatest tendency for creep in the {111} indented samples, compared with the samples indented close to the {001} and {101} surfaces. Scanning electron microscopy and cross-sectional transmission electron microscopy revealed slip bands and dislocations in all samples. The slip band patterns on the indented surfaces were influencedmore » by the grain orientations. Deformation twinning was observed only under the {001} indented surfaces. Finally, microstructural analysis and molecular dynamics modeling correlated the anisotropic nanoindentation-creep behavior with the different dislocation substructures formed during indentation, which resulted from the dislocation reactions of certain active slip systems that are determined by the indented grain orientations.« less

  8. Mechanical properties of amorphous and devitrified Ni-Zr alloy thin films: A cyclic nanoindentation study

    NASA Astrophysics Data System (ADS)

    Bhattacharya, Debarati; Chatterjee, Arnomitra; Jana, Swapan

    2018-04-01

    Thin films of Ni-Zr glassy alloy were deposited at room temperature by magnetron co-sputtering. The alloy films were vacuum annealed in steps of 200°C from room temperature up to 800 °C, where devitrification finally occurred. Mechanical properties of the films were measured after each thermal anneal, through (cyclic) nanoindentation technique. The hardness values were observed to steadily increase with annealing temperature, as the alloy films underwent an amorphous to crystalline transformation. Grazing incidence X-ray diffraction measurements were performed on the as-deposited and annealed films both before and after nanoindentation. The resistance to plastic deformation was strongly linked to the (nano)structure of the material.

  9. Research on the tool holder mode in high speed machining

    NASA Astrophysics Data System (ADS)

    Zhenyu, Zhao; Yongquan, Zhou; Houming, Zhou; Xiaomei, Xu; Haibin, Xiao

    2018-03-01

    High speed machining technology can improve the processing efficiency and precision, but also reduce the processing cost. Therefore, the technology is widely regarded in the industry. With the extensive application of high-speed machining technology, high-speed tool system has higher and higher requirements on the tool chuck. At present, in high speed precision machining, several new kinds of clip heads are as long as there are heat shrinkage tool-holder, high-precision spring chuck, hydraulic tool-holder, and the three-rib deformation chuck. Among them, the heat shrinkage tool-holder has the advantages of high precision, high clamping force, high bending rigidity and dynamic balance, etc., which are widely used. Therefore, it is of great significance to research the new requirements of the machining tool system. In order to adapt to the requirement of high speed machining precision machining technology, this paper expounds the common tool holder technology of high precision machining, and proposes how to select correctly tool clamping system in practice. The characteristics and existing problems are analyzed in the tool clamping system.

  10. Accounting for structural compliance in nanoindentation measurements of bioceramic bone scaffolds

    Treesearch

    Juan Vivanco; Joseph E. Jakes; Josh Slane; Heidi-Lynn Ploeg

    2014-01-01

    Structural properties have been shown to be critical in the osteoconductive capacity and strength of bioactive ceramic bone scaffolds. Given the cellular foam-like structure of bone scaffolds, nanoindentation has been used as a technique to assess the mechanical properties of individual components of the scaffolds. Nevertheless, nanoindents placed on scaffolds may...

  11. 19 CFR 134.23 - Containers or holders designed for or capable of reuse.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 1 2011-04-01 2011-04-01 false Containers or holders designed for or capable of reuse. 134.23 Section 134.23 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY COUNTRY OF ORIGIN MARKING Marking of Containers or Holders § 134.23 Containers or holders designed for or...

  12. Filter holder and gasket assembly for candle or tube filters

    DOEpatents

    Lippert, T.E.; Alvin, M.A.; Bruck, G.J.; Smeltzer, E.E.

    1999-03-02

    A filter holder and gasket assembly are disclosed for holding a candle filter element within a hot gas cleanup system pressure vessel. The filter holder and gasket assembly includes a filter housing, an annular spacer ring securely attached within the filter housing, a gasket sock, a top gasket, a middle gasket and a cast nut. 9 figs.

  13. Simulation and experimental analysis of nanoindentation and mechanical properties of amorphous NiAl alloys.

    PubMed

    Wang, Chih-Hao; Fang, Te-Hua; Cheng, Po-Chien; Chiang, Chia-Chin; Chao, Kuan-Chi

    2015-06-01

    This paper used numerical and experimental methods to investigate the mechanical properties of amorphous NiAl alloys during the nanoindentation process. A simulation was performed using the many-body tight-binding potential method. Temperature, plastic deformation, elastic recovery, and hardness were evaluated. The experimental method was based on nanoindentation measurements, allowing a precise prediction of Young's modulus and hardness values for comparison with the simulation results. The indentation simulation results showed a significant increase of NiAl hardness and elastic recovery with increasing Ni content. Furthermore, the results showed that hardness and Young's modulus increase with increasing Ni content. The simulation results are in good agreement with the experimental results. Adhesion test of amorphous NiAl alloys at room temperature is also described in this study.

  14. 12 CFR 611.1215 - Communications with the public and equity holders.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Communications with the public and equity holders. 611.1215 Section 611.1215 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM... holders. (a) Communications after commencement resolution and before termination. The terminating...

  15. Nano-Indentation of Aluminium Reinforced Metallic Glass Composites: A Molecular Dynamics Study

    NASA Astrophysics Data System (ADS)

    Yadav, D.; Gupta, P.; Yedla, N.

    2018-03-01

    Molecular dynamics (MD) simulations are performed for nanoindentation on metal (Al)-metallic glass (Cu50Zr50) reinforced composites to investigate the mechanical properties and the effects of volume percentage on behavior of the load-displacement curves. The interaction among Al-Cu-Zr is modelled using a EAM (Embedded Atom Method) potential. Simulation box size of 100 Å (x) × 100 Å (y) × 100 Å (z) is modelled for investigating the properties of the sintered models by altering the volume percentage on the scale of 5%-20%. Nanoindentation is done along y-direction with a spherical diamond indenter at temperature of 300 K with constant indentation speed of 100 m/s. NVT ensemble is used with a timestep of 0.002 ps. Investigations on the effect of volume percentage show that as volume percentage of Metallic Glass (MG) increases, the corresponding Load required to penetrate inside the sample also increases. As a result of this Hardness also increase as volume percentage varies from 5% to 20%.

  16. Nano-indentation used to study pyramidal slip in GaN single crystals

    NASA Astrophysics Data System (ADS)

    Krimsky, E.; Jones, K. A.; Tompkins, R. P.; Rotella, P.; Ligda, J.; Schuster, B. E.

    2018-02-01

    The nucleation and structure of dislocations created by the nano-indentation of GaN samples with dislocation densities ≈103, 106 or 109 ⊥/cm2 were studied in the interest of learning how dislocations can be created to relieve the mismatch strain in ternary nitride films grown on (0001) oriented binary nitride substrates. Using transmission electron microscopy and stress analyses to assist in interpreting the nano-indentation data, we determined that the pop-ins in the indenter load vs. penetration depth curves are created by an avalanche process at stresses well above the typical yield stress. The process begins by the homogeneous formation of a basal plane screw dislocation that triggers the formation of pyramidal and other basal plane dislocations that relieve the excess stored elastic energy. It appears that pyramidal slip can occur on either the {1122} or {0111} planes, as there is little resistance to the cross slip of screw dislocations.

  17. Lathe tool bit and holder for machining fiberglass materials

    NASA Technical Reports Server (NTRS)

    Winn, L. E. (Inventor)

    1972-01-01

    A lathe tool and holder combination for machining resin impregnated fiberglass cloth laminates is described. The tool holder and tool bit combination is designed to accommodate a conventional carbide-tipped, round shank router bit as the cutting medium, and provides an infinite number of cutting angles in order to produce a true and smooth surface in the fiberglass material workpiece with every pass of the tool bit. The technique utilizes damaged router bits which ordinarily would be discarded.

  18. Multiscale characteristics of mechanical and mineralogical heterogeneity using nanoindentation and Maps Mineralogy in Mancos Shale

    NASA Astrophysics Data System (ADS)

    Yoon, H.; Mook, W. M.; Dewers, T. A.

    2017-12-01

    Multiscale characteristics of textural and compositional (e.g., clay, cement, organics, etc.) heterogeneity profoundly influence the mechanical properties of shale. In particular, strongly anisotropic (i.e., laminated) heterogeneities are often observed to have a significant influence on hydrological and mechanical properties. In this work, we investigate a sample of the Cretaceous Mancos Shale to explore the importance of lamination, cements, organic content, and the spatial distribution of these characteristics. For compositional and structural characterization, the mineralogical distribution of thin core sample polished by ion-milling is analyzed using QEMSCAN® with MAPS MineralogyTM (developed by FEI Corporoation). Based on mineralogy and organic matter distribution, multi-scale nanoindentation testing was performed to directly link compositional heterogeneity to mechanical properties. With FIB-SEM (3D) and high-magnitude SEM (2D) images, key nanoindentation patterns are analyzed to evaluate elastic and plastic responses. Combined with MAPs Mineralogy data and fine-resolution BSE images, nanoindentation results are explained as a function of compositional and structural heterogeneity. Finite element modeling is used to quantitatively evaluate the link between the heterogeneity and mechanical behavior during nanoindentation. In addition, the spatial distribution of compositional heterogeneity, anisotropic bedding patterns, and mechanical anisotropy are employed as inputs for multiscale brittle fracture simulations using a phase field model. Comparison of experimental and numerical simulations reveal that proper incorporation of additional material information, such as bedding layer thickness and other geometrical attributes of the microstructures, may yield improvements on the numerical predictions of the mesoscale fracture patterns and hence the macroscopic effective toughness. Sandia National Laboratories is a multimission laboratory managed and operated by

  19. 7 CFR 1463.105 - Base quota levels for eligible quota holders.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 10 2011-01-01 2011-01-01 false Base quota levels for eligible quota holders. 1463.105 Section 1463.105 Agriculture Regulations of the Department of Agriculture (Continued) COMMODITY... TRANSITION PROGRAM Tobacco Transition Payment Program § 1463.105 Base quota levels for eligible quota holders...

  20. 7 CFR 1463.105 - Base quota levels for eligible quota holders.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 10 2012-01-01 2012-01-01 false Base quota levels for eligible quota holders. 1463.105 Section 1463.105 Agriculture Regulations of the Department of Agriculture (Continued) COMMODITY... TRANSITION PROGRAM Tobacco Transition Payment Program § 1463.105 Base quota levels for eligible quota holders...

  1. Holder for rotating glass body

    DOEpatents

    Kolleck, Floyd W.

    1978-04-04

    A device is provided for holding and centering a rotating glass body such as a rod or tube. The device includes a tubular tip holder which may be held in a lathe chuck. The device can utilize a variety of centering tips each adapted for a particular configuration, such as a glass O-ring joint or semi-ball joint.

  2. Nanoindentation of the interphase region of a wood-reinforced polypropylene composite

    Treesearch

    Joseph E. Jakes; John C. Hermanson; Donald S. Stone

    2007-01-01

    The interphase region of a wood-reinforced polypropylene (PP) composite was investigated with nanoindentation techniques capable of separating intrinsic properties of PP in the interphase region from the effect of elastic discontinuity caused by the nearby wood cell wall. From data collected in this experiment, no differences in hardness or Young’s modulus for PP were...

  3. Spherical nanoindentation of proton irradiated 304 stainless steel: A comparison of small scale mechanical test techniques for measuring irradiation hardening

    NASA Astrophysics Data System (ADS)

    Weaver, Jordan S.; Pathak, Siddhartha; Reichardt, Ashley; Vo, Hi T.; Maloy, Stuart A.; Hosemann, Peter; Mara, Nathan A.

    2017-09-01

    Experimentally quantifying the mechanical effects of radiation damage in reactor materials is necessary for the development and qualification of new materials for improved performance and safety. This can be achieved in a high-throughput fashion through a combination of ion beam irradiation and small scale mechanical testing in contrast to the high cost and laborious nature of bulk testing of reactor irradiated samples. The current work focuses on using spherical nanoindentation stress-strain curves on unirradiated and proton irradiated (10 dpa at 360 °C) 304 stainless steel to quantify the mechanical effects of radiation damage. Spherical nanoindentation stress-strain measurements show a radiation-induced increase in indentation yield strength from 1.36 GPa to 2.72 GPa and a radiation-induced increase in indentation work hardening rate of 10 GPa-30 GPa. These measurements are critically compared against Berkovich nanohardness, micropillar compression, and micro-tension measurements on the same material and similar grain orientations. The ratio of irradiated to unirradiated yield strength increases by a similar factor of 2 when measured via spherical nanoindentation or Berkovich nanohardness testing. A comparison of spherical indentation stress-strain curves to uniaxial (micropillar and micro-tension) stress-strain curves was achieved using a simple scaling relationship which shows good agreement for the unirradiated condition and poor agreement in post-yield behavior for the irradiated condition. The disagreement between spherical nanoindentation and uniaxial stress-strain curves is likely due to the plastic instability that occurs during uniaxial tests but is absent during spherical nanoindentation tests.

  4. Spherical nanoindentation of proton irradiated 304 stainless steel: A comparison of small scale mechanical test techniques for measuring irradiation hardening

    DOE PAGES

    Weaver, Jordan S.; Pathak, Siddhartha; Reichardt, Ashley; ...

    2017-06-27

    Experimentally quantifying the mechanical effects of radiation damage in reactor materials is necessary for the development and qualification of new materials for improved performance and safety. This can be achieved in a high-throughput fashion through a combination of ion beam irradiation and small scale mechanical testing in contrast to the high cost and laborious nature of bulk testing of reactor irradiated samples. The current paper focuses on using spherical nanoindentation stress-strain curves on unirradiated and proton irradiated (10 dpa at 360 °C) 304 stainless steel to quantify the mechanical effects of radiation damage. Spherical nanoindentation stress-strain measurements show a radiation-inducedmore » increase in indentation yield strength from 1.36 GPa to 2.72 GPa and a radiation-induced increase in indentation work hardening rate of 10 GPa–30 GPa. These measurements are critically compared against Berkovich nanohardness, micropillar compression, and micro-tension measurements on the same material and similar grain orientations. The ratio of irradiated to unirradiated yield strength increases by a similar factor of 2 when measured via spherical nanoindentation or Berkovich nanohardness testing. A comparison of spherical indentation stress-strain curves to uniaxial (micropillar and micro-tension) stress-strain curves was achieved using a simple scaling relationship which shows good agreement for the unirradiated condition and poor agreement in post-yield behavior for the irradiated condition. Finally, the disagreement between spherical nanoindentation and uniaxial stress-strain curves is likely due to the plastic instability that occurs during uniaxial tests but is absent during spherical nanoindentation tests.« less

  5. Spherical nanoindentation of proton irradiated 304 stainless steel: A comparison of small scale mechanical test techniques for measuring irradiation hardening

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weaver, Jordan S.; Pathak, Siddhartha; Reichardt, Ashley

    Experimentally quantifying the mechanical effects of radiation damage in reactor materials is necessary for the development and qualification of new materials for improved performance and safety. This can be achieved in a high-throughput fashion through a combination of ion beam irradiation and small scale mechanical testing in contrast to the high cost and laborious nature of bulk testing of reactor irradiated samples. The current paper focuses on using spherical nanoindentation stress-strain curves on unirradiated and proton irradiated (10 dpa at 360 °C) 304 stainless steel to quantify the mechanical effects of radiation damage. Spherical nanoindentation stress-strain measurements show a radiation-inducedmore » increase in indentation yield strength from 1.36 GPa to 2.72 GPa and a radiation-induced increase in indentation work hardening rate of 10 GPa–30 GPa. These measurements are critically compared against Berkovich nanohardness, micropillar compression, and micro-tension measurements on the same material and similar grain orientations. The ratio of irradiated to unirradiated yield strength increases by a similar factor of 2 when measured via spherical nanoindentation or Berkovich nanohardness testing. A comparison of spherical indentation stress-strain curves to uniaxial (micropillar and micro-tension) stress-strain curves was achieved using a simple scaling relationship which shows good agreement for the unirradiated condition and poor agreement in post-yield behavior for the irradiated condition. Finally, the disagreement between spherical nanoindentation and uniaxial stress-strain curves is likely due to the plastic instability that occurs during uniaxial tests but is absent during spherical nanoindentation tests.« less

  6. 14 CFR 121.652 - Landing weather minimums: IFR: All certificate holders.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Landing weather minimums: IFR: All certificate holders. 121.652 Section 121.652 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... Rules § 121.652 Landing weather minimums: IFR: All certificate holders. (a) If the pilot in command of...

  7. 14 CFR 121.652 - Landing weather minimums: IFR: All certificate holders.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Landing weather minimums: IFR: All certificate holders. 121.652 Section 121.652 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... Rules § 121.652 Landing weather minimums: IFR: All certificate holders. (a) If the pilot in command of...

  8. 14 CFR 121.652 - Landing weather minimums: IFR: All certificate holders.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Landing weather minimums: IFR: All certificate holders. 121.652 Section 121.652 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... Rules § 121.652 Landing weather minimums: IFR: All certificate holders. (a) If the pilot in command of...

  9. 14 CFR 121.652 - Landing weather minimums: IFR: All certificate holders.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Landing weather minimums: IFR: All certificate holders. 121.652 Section 121.652 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... Rules § 121.652 Landing weather minimums: IFR: All certificate holders. (a) If the pilot in command of...

  10. 14 CFR 121.652 - Landing weather minimums: IFR: All certificate holders.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Landing weather minimums: IFR: All certificate holders. 121.652 Section 121.652 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... Rules § 121.652 Landing weather minimums: IFR: All certificate holders. (a) If the pilot in command of...

  11. Nanoindentation characterisation of human colorectal cancer cells considering cell geometry, surface roughness and hyperelastic constitutive behaviour

    NASA Astrophysics Data System (ADS)

    Boccaccio, Antonio; Uva, Antonio E.; Papi, Massimiliano; Fiorentino, Michele; De Spirito, Marco; Monno, Giuseppe

    2017-01-01

    Characterisation of the mechanical behaviour of cancer cells is an issue of crucial importance as specific cell mechanical properties have been measured and utilized as possible biomarkers of cancer progression. Atomic force microscopy certainly occupies a prominent place in the field of the mechanical characterisation devices. We developed a hybrid approach to characterise different cell lines (SW620 and SW480) of the human colon carcinoma submitted to nanoindentation measurements. An ad hoc algorithm was written that compares the force-indentation curves experimentally retrieved with those predicted by a finite element model that simulates the nanoindentation process and reproduces the cell geometry and the surface roughness. The algorithm perturbs iteratively the values of the cell mechanical properties implemented in the finite element model until the difference between the experimental and numerical force-indentation curves reaches the minimum value. The occurrence of this indicates that the implemented material properties are very close to the real ones. Different hyperelastic constitutive models, such as Arruda-Boyce, Mooney-Rivlin and Neo-Hookean were utilized to describe the structural behaviour of indented cells. The algorithm was capable of separating, for all the cell lines investigated, the mechanical properties of cell cortex and cytoskeleton. Material properties determined via the algorithm were different with respect to those obtained with the Hertzian contact theory. This demonstrates that factors such as: the cell geometry/anatomy and the hyperelastic constitutive behaviour, which are not contemplated in the Hertz’s theory hypotheses, do affect the nanoindentation measurements. The proposed approach represents a powerful tool that, only on the basis of nanoindentation measurements, is capable of characterising material at the subcellular level.

  12. Study on the influence of leucine-rich amelogenin peptide (LRAP) on the remineralization of enamel defects via micro-focus x-ray computed tomography and nanoindentation.

    PubMed

    Bagheri G, Hossein; Sadr, Alireza; Espigares, Jorge; Hariri, Ilnaz; Nakashima, Syozi; Hamba, Hidenori; Shafiei, Farhad; Moztarzadeh, Fathollah; Tagami, Junji

    2015-06-04

    Regeneration of severely damaged enamel (e.g. deep demineralized lesions) is currently not possible, because the structural units of enamel crystal construction are removed after its maturation. The aim of this in vitro study was to evaluate the effect of surface impregnation by leucine-rich amelogenin peptide (LRAP) on the remineralization of eroded enamel using micro-focus x-ray computed tomography (µCT). Fifteen bovine enamel blocks were embedded in resin and three zones (sound, demineralization, and remineralization) were defined on each specimen. Lesions were prepared by immersing the samples in demineralization solution for 7 d. The samples were soaked in distilled water or 60 or 120 µg mL(-1) solution of LRAP in water for 30 min. After the surface treatment, specimens were incubated in artificial saliva for either 5 or 10 d at 37 °C. The amount of mineral gain (dΔZ%) and the relative changes in the lesion depth (dLD%), obtained from µCT, were used to evaluate the effect of LRAP on the remineralization of lesions. The effects of LRAP on cross-sectional integrated hardness ΔINH were studied after 10 d using nanoindentation. ANOVA test was used to determine the effect of time and/or LRAP concentration on dΔZ%, dLD% and ΔINH mean values. Tukey's analysis was used for multiple comparison testing (α = 0.05). Analysis of µCT data showed significant effect of time and LRAP concentration on the dΔZ% (p = 0.013, p = 0.003) and the dLD% (p  <  0.001, p = 0.002) mean values. The nanoindentation hardness was significantly improved by 120 µg mL(-1) LRAP (p = 0.02). Also, the peptide treatment affected the mineral distribution throughout the lesion by inhibiting of superficial deposition. This study showed that the treatment of eroded lesions in enamel by LRAP can improve and regulate the pattern of remineralization in vitro.

  13. Double-tilt in situ TEM holder with ultra-high stability.

    PubMed

    Xu, Mingjie; Dai, Sheng; Blum, Thomas; Li, Linze; Pan, Xiaoqing

    2018-05-06

    A double tilting holder with high stability is essential for acquiring atomic-scale information by transmission electron microscopy (TEM), but the availability of such holders for in situ TEM studies under various external stimuli is limited. Here, we report a unique design of seal-bearing components that provides ultra-high stability and multifunctionality (including double tilting) in an in situ TEM holder. The seal-bearing subsystem provides superior vibration damping and electrical insulation while maintaining excellent vacuum sealing and small form factor. A wide variety of in situ TEM applications including electrical measurement, STM mapping, photovoltaic studies, and CL spectroscopy can be performed on this platform with high spatial resolution imaging and electrical sensitivity at the pA scale. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. 42 CFR 60.53 - Notification to lender or holder of change in enrollment status.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... different), the student's Social Security number, the date of the change in the enrollment status, or... 42 Public Health 1 2010-10-01 2010-10-01 false Notification to lender or holder of change in... holder of change in enrollment status. Each school must notify the holder of a HEAL loan of any change in...

  15. Quick-Change Optical-Filter Holder

    NASA Technical Reports Server (NTRS)

    Leone, Peter

    1988-01-01

    Dark slide and interlock protect against ambient light. Quick-change filter holder contains interlocking mechanism preventing simultaneous removal of both dark slide and filter drawer. Designed for use with Band pass optical filters in 10 channels leading to photomultiplier tubes in water-vapor lidar/ozone instrument, mechanism can be modified to operate in other optical systems requiring optical change in filters.

  16. The deformation of gum metal under nanoindentation and sub-micron pillar compression

    NASA Astrophysics Data System (ADS)

    Withey, Elizabeth Ann

    Reaching ideal strength has proven to be difficult in most materials. Dislocation slip, phase transformations, twinning, and fracture all tend to occur at stresses well below the ideal strength of a material. Only on very small scales has it been possible to approach ideal strength. Thus, it was of great interest when a set of beta-Ti alloys, Gum Metal, were found to have a bulk yield strength close to half of its ideal strength. However, some recent studies have questioned the reliability of this claim. Several studies have suggested Gum Metal deforms by dislocation slip. Others have suggested the possibility of transformation-induced plasticity. The present study was undertaken in order to help clarify if and how Gum Metal can reach ideal strength. Two different experiments, ex situ nanoindentation and quantitative in situ nanopillar compression in a transmission electron microscope to correlate real-time deformation behavior, were performed on a single composition of Gum Metal, Ti-23Nb-0.7Ta-2Zr-1.20 at. %, obtained from Toyota Central R&D Laboratories. Nanoindented specimens were thinned from the bottom surface until the pits of multiple indentations became electron-transparent allowing for qualitative analysis of the deformation microstructure in both fully cold-worked and solution-treated specimens. Real-time load-displacement behavior from the nanopillar compression tests was correlated with real-time video recorded during each compression to determine both the compressive strength of each pillar and the timing and strengths of different deformation behaviors observed. Combining the results from both experiments provided several important conclusions. First, Gum Metal approaches and can attain ideal strength in nanopillars regardless of processing condition. While dislocations exist in Gum Metal, they can be tightly pinned by obstacles with spacing less than ˜20 nm, which should inhibit their motion at strengths below the ideal shear strength. The plastic

  17. The hardness of the hydroxyapatite-titania bilayer coatings by microindentation and nanoindentation testing

    NASA Astrophysics Data System (ADS)

    SIDANE, Djahida; KHIREDDINE, Hafit; YALA, Sabeha

    2017-12-01

    The aim of this paper is to investigate the effect of the addition of titania (TiO2) inner-layer on the morphological and mechanical properties of hydroxyapatite (HAP) bioceramic coatings deposited on 316L stainless steel (316L SS) by sol-gel method in order to improve the properties of hydroxyapatite and expand its clinical application. The addition of TiO2 as sublayer of a hydroxyapatite coating results in changes in surface morphology as well as an increase of the microhardness. The deposition of the inner-layer provides the formation of new types of hydroxyapatite coatings at the same condition of annealing. This represents an advantage for the various applications of the hydroxyapatite bioceramic in the medical field. Classical hardness measurements conducted on the coated systems under the same indentation load (10g) indicated that the microhardness of the HAP coating is improved by the addition of TiO2 inner-layer on the 316L stainless steel substrate. The hardness values obtained from both classical tests in microindentation and the continuous stiffness measurement mode in nanoindentation are slightly different. This is because nanoindentation is more sensitive to the surface roughness and the influence of defects that could be present into the material. Moreover, nanoindentation is the most useful method to separate the contribution of each layer in the bilayer coatings. In this study, the hardness is comparable with those reported previously for pure HAP ceramics (1.0-5.5 GPa) which are close to the properties of natural teeth.

  18. Determination of Mechanical Properties of Spatially Heterogeneous Breast Tissue Specimens Using Contact Mode Atomic Force Microscopy (AFM)

    PubMed Central

    Roy, Rajarshi; Desai, Jaydev P.

    2016-01-01

    This paper outlines a comprehensive parametric approach for quantifying mechanical properties of spatially heterogeneous thin biological specimens such as human breast tissue using contact-mode Atomic Force Microscopy. Using inverse finite element (FE) analysis of spherical nanoindentation, the force response from hyperelastic material models is compared with the predicted force response from existing analytical contact models, and a sensitivity study is carried out to assess uniqueness of the inverse FE solution. Furthermore, an automation strategy is proposed to analyze AFM force curves with varying levels of material nonlinearity with minimal user intervention. Implementation of our approach on an elastic map acquired from raster AFM indentation of breast tissue specimens indicates that a judicious combination of analytical and numerical techniques allow more accurate interpretation of AFM indentation data compared to relying on purely analytical contact models, while keeping the computational cost associated an inverse FE solution with reasonable limits. The results reported in this study have several implications in performing unsupervised data analysis on AFM indentation measurements on a wide variety of heterogeneous biomaterials. PMID:25015130

  19. 77 FR 69650 - Agency Information Collection Activities: Holders or Containers Which Enter the United States...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-20

    ... Activities: Holders or Containers Which Enter the United States Duty Free AGENCY: U.S. Customs and Border... information collection requirement concerning the Holders or Containers which Enter the United States Duty... concerning the following information collection: Title: Holders or Containers which Enter the United States...

  20. Nanoindentation hardness of particles used in magnetorheological finishing (MRF).

    PubMed

    Shorey, A B; Kwong, K M; Johnson, K M; Jacobs, S D

    2000-10-01

    Knowledge of the hardness of abrasive particles that are used in polishing is a key to the fundamental understanding of the mechanisms of material removal. The magnetorheological-finishing process uses both magnetic and nonmagnetic abrasive particles during polishing. The nanohardnesses of the micrometer-sized magnetic carbonyl iron and nonmagnetic abrasive particles have been measured successfully by use of novel, to our knowledge, sample-preparation and nanoindentation techniques. Some of the results reported compare favorably with existing microhardness data found in the literature, whereas other results are new.

  1. Development and positioning reliability of a TMS coil holder for headache research.

    PubMed

    Chronicle, Edward P; Pearson, A Jane; Matthews, Cheryl

    2005-01-01

    Accurate and reproducible coil positioning is important for headache research using transcranial magnetic stimulation protocols. We aimed to design a transcranial magnetic stimulation coil holder and demonstrate reliability of test-retest coil positioning. A coil holder was developed and manufactured according to three principles of stability, durability, and three-dimensional positional accuracy. Reliability of coil positioning was assessed by stimulating over the motor cortex of four neurologically normal subjects and recording finger muscle responses, both at a test phase and a retest phase several hours later. In all four subjects, repositioning of the transcranial magnetic stimulation coil solely on the basis of coil holder coordinates was accurate to within 2 mm. The coil holder demonstrated good test-retest reliability of coil positioning, and is thus a promising tool for transcranial magnetic stimulation-based headache research, particularly studies of prophylactic drug effect where several laboratory visits with identical coil positioning are necessary.

  2. Plastic deformation behaviors of Ni- and Zr-based bulk metallic glasses subjected to nanoindentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weizhong, Liang, E-mail: wzliang1966@126.com; Zhiliang, Ning; Zhenqian, Dang

    2013-12-15

    Plastic deformation behaviors of Ni{sub 42}Ti{sub 20}Zr{sub 21.5}Al{sub 8}Cu{sub 5}Si{sub 3.5} and Zr{sub 51}Ti{sub 5}Ni{sub 10}Cu{sub 25}Al{sub 9} bulk metallic glasses at room temperature were studied by nanoindentation testing and atomic force microscopy under equivalent indentation experimental conditions. The different chemical composition of these two bulk metallic glasses produced variant tendencies for displacement serrated flow to occur during the loading process. The nanoindentation strain rate was calculated as a function of indentation displacement in order to verify the occurrence of displacement serrated flow at different loading rates. Atomic force microscopy revealed decreasing numbers of discrete shear bands around the indentationmore » sites as loading rates increased from 0.025 to 2.5 mNs{sup −1}. Variations in plastic deformation behaviors between Ni and Zr-based glasses materials can be explained by the different metastable microstructures and thermal stabilities of the two materials. The mechanism governing plastic deformation of these metallic glasses was analyzed in terms of an established model of the shear transformation zone. - Highlights: • Plastic deformation of Ni- and Zr-based BMG is studied under identical conditions • Zr-based BMG undergoes a greater extent of plastic deformation than Ni-based BMG • Nanoindentation strain rate is studied to clarify variation in plastic deformation • Metastable microstructure, thermal stability affect BMG plastic deformation.« less

  3. An improved FIB sample preparation technique for site-specific plan-view specimens: A new cutting geometry.

    PubMed

    Li, Chen; Habler, Gerlinde; Baldwin, Lisa C; Abart, Rainer

    2018-01-01

    Focused ion beam (FIB) sample preparation technique in plan-view geometry allows direct correlations of the atomic structure study via transmission electron microscopy with micrometer-scale property measurements. However, one main technical difficulty is that a large amount of material must be removed underneath the specimen. Furthermore, directly monitoring the milling process is difficult unless very large material volumes surrounding the TEM specimen site are removed. In this paper, a new cutting geometry is introduced for FIB lift-out sample preparation with plan-view geometry. Firstly, an "isolated" cuboid shaped specimen is cut out, leaving a "bridge" connecting it with the bulk material. Subsequently the two long sides of the "isolated" cuboid are wedged, forming a triangular prism shape. A micromanipulator needle is used for in-situ transfer of the specimen to a FIB TEM grid, which has been mounted parallel with the specimen surface using a simple custom-made sample slit. Finally, the grid is transferred to the standard FIB grid holder for final thinning with standard procedures. This new cutting geometry provides clear viewing angles for monitoring the milling process, which solves the difficulty of judging whether the specimen has been entirely detached from the bulk material, with the least possible damage to the surrounding materials. With an improved success rate and efficiency, this plan-view FIB lift-out specimen preparation technique should have a wide application for material science. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  4. A novel method for single sample multi-axial nanoindentation of hydrated heterogeneous tissues based on testing great white shark jaws.

    PubMed

    Ferrara, Toni L; Boughton, Philip; Slavich, Eve; Wroe, Stephen

    2013-01-01

    Nanomechanical testing methods that are suitable for a range of hydrated tissues are crucial for understanding biological systems. Nanoindentation of tissues can provide valuable insights into biology, tissue engineering and biomimetic design. However, testing hydrated biological samples still remains a significant challenge. Shark jaw cartilage is an ideal substrate for developing a method to test hydrated tissues because it is a unique heterogeneous composite of both mineralized (hard) and non-mineralized (soft) layers and possesses a jaw geometry that is challenging to test mechanically. The aim of this study is to develop a novel method for obtaining multidirectional nanomechanical properties for both layers of jaw cartilage from a single sample, taken from the great white shark (Carcharodon carcharias). A method for obtaining multidirectional data from a single sample is necessary for examining tissue mechanics in this shark because it is a protected species and hence samples may be difficult to obtain. Results show that this method maintains hydration of samples that would otherwise rapidly dehydrate. Our study is the first analysis of nanomechanical properties of great white shark jaw cartilage. Variation in nanomechanical properties were detected in different orthogonal directions for both layers of jaw cartilage in this species. The data further suggest that the mineralized layer of shark jaw cartilage is less stiff than previously posited. Our method allows multidirectional nanomechanical properties to be obtained from a single, small, hydrated heterogeneous sample. Our technique is therefore suitable for use when specimens are rare, valuable or limited in quantity, such as samples obtained from endangered species or pathological tissues. We also outline a method for tip-to-optic calibration that facilitates nanoindentation of soft biological tissues. Our technique may help address the critical need for a nanomechanical testing method that is applicable

  5. Financial Statistics of Noncommercial Television License Holders: Fiscal Year 1970. Revised Edition.

    ERIC Educational Resources Information Center

    Pedone, Ronald J.; And Others

    Fiscal year 1970 financial data for 129 educational television license holders responsible for 195 stations in the aggregate United States are presented. The data are grouped by type of license holder (institution of higher education, local public school system, state authority, or community organization) and region (North Atlantic, Great Lakes…

  6. Recent advances in small-scale mechanical property measurement by nanoindentation

    DOE PAGES

    Pharr, George Mathews

    2015-08-25

    Since its initial development in the early 1980’s [1], nanoindentation has matured into one of the premier testing techniques for measuring mechanical properties at the micrometer and sub-micrometer scales and has emerged as a critical tool that has helped to shape the nanotechnology revolution. At the heart of the technique are testing systems with simple but precise force actuators and displacement measuring devices that record the force–displacement record as a diamond indenter, usually the form of a pyramid or a sphere, is pressed into and withdrawn from a small region in the surface of a material of interest. The nano-scalemore » force–displacement data, which can be obtained with a spatial resolution as small as a few nanometers, contains a wealth of information about the local mechanical properties [2], [3] and [4]. This enables the mechanical characterization of very thin films, like those used in the semiconductor, magnetic storage, and hard coatings industries, as well as very small precipitates, particles and second phases, many of which may not exist in bulk form and cannot be characterized by traditional mechanical testing methods. Here, computer automation of nanoindentation testing systems now routinely provides for complete two-dimensional mapping of properties over regions stretching from sub-micron to millimeters in scale.« less

  7. Light-Curing Volumetric Shrinkage in Dimethacrylate-Based Dental Composites by Nanoindentation and PAL Study.

    PubMed

    Shpotyuk, Olha; Adamiak, Stanislaw; Bezvushko, Elvira; Cebulski, Jozef; Iskiv, Maryana; Shpotyuk, Oleh; Balitska, Valentina

    2017-12-01

    Light-curing volumetric shrinkage in dimethacrylate-based dental resin composites Dipol® is examined through comprehensive kinetics research employing nanoindentation measurements and nanoscale atomic-deficient study with lifetime spectroscopy of annihilating positrons. Photopolymerization kinetics determined through nanoindentation testing is shown to be described via single-exponential relaxation function with character time constants reaching respectively 15.0 and 18.7 s for nanohardness and elastic modulus. Atomic-deficient characteristics of composites are extracted from positron lifetime spectra parameterized employing unconstrained x3-term fitting. The tested photopolymerization kinetics can be adequately reflected in time-dependent changes observed in average positron lifetime (with 17.9 s time constant) and fractional free volume of positronium traps (with 18.6 s time constant). This correlation proves that fragmentation of free-volume positronium-trapping sites accompanied by partial positronium-to-positron traps conversion determines the light-curing volumetric shrinkage in the studied composites.

  8. 26 CFR 1.860C-1 - Taxation of holders of residual interests.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Taxation of holders of residual interests. 1.860C-1 Section 1.860C-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Real Estate Investment Trusts § 1.860C-1 Taxation of holders...

  9. Nanoindentation hardness of intertubular dentin in sound, demineralized and natural caries-affected dentin.

    PubMed

    Joves, Gerardo José; Inoue, Go; Sadr, Alireza; Nikaido, Toru; Tagami, Junji

    2014-04-01

    The purpose of this study was to investigate the mechanical properties of intertubular dentin in sound, natural caries-affected (NCAD) and artificial caries-affected dentin (ACAD) using nanoindentation. Non-caries molars and caries molars with International Caries Detection and Assessment System (ICDAS II) score 5 at the occlusal site were used and caries was excavated using a spoon excavator, a round bur at low speed without water and a dye solution as guidance to detect the infected tissue. Specimens with remaining dentin thickness (RDT) >2mm were selected. ACAD teeth were created from sound teeth over 7 days in a demineralizing solution. Specimens were embedded into plastic rings with acrylic resin and then sagittal mesial-distal sectioned from crown to the long axis of the root under cooling water using a low-speed diamond blade. The surface of interest was fine polished sequentially. Hardness measurement was performed within an axial depth of 1000μm with at least of 320 indentations on each sample. Mann-Whitney U Test was used to compare the hardness as the variable among different dentin types (SOUND, NCAD and ACAD) at each dentin depth level. There was no significant difference in nanohardness between NCAD and ACAD up to a depth of 130μm (p>0.05). NCAD consistently showed lower hardness. ACAD showed no significant difference in hardness with SOUND dentin beyond 190μm (p<0.05). The lesion front in ACAD was considered to be located around the depth of 180μm. Natural and artificial caries-affected dentin tissues were superficially comparable in intertubular nanohardness. There is a certain layer within the natural caries-affected dentin with higher hardness; however the long-term effects of caries beneath the lesion extend deeply through intertubular dentin. Sound dentin at deep areas (close to the pulp chamber) is considered to be soft. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. 7 CFR 1463.103 - Eligible quota holder.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Eligible quota holder. 1463.103 Section 1463.103 Agriculture Regulations of the Department of Agriculture (Continued) COMMODITY CREDIT CORPORATION, DEPARTMENT OF AGRICULTURE LOANS, PURCHASES, AND OTHER OPERATIONS 2005-2014 TOBACCO TRANSITION PROGRAM Tobacco...

  11. 21 CFR 316.30 - Annual reports of holder of orphan-drug designation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Annual reports of holder of orphan-drug... SERVICES (CONTINUED) DRUGS FOR HUMAN USE ORPHAN DRUGS Designation of an Orphan Drug § 316.30 Annual reports of holder of orphan-drug designation. Within 14 months after the date on which a drug was designated...

  12. Deformation mechanisms during nanoindentation of sodium borosilicate glasses of nuclear interest.

    PubMed

    Kilymis, D A; Delaye, J-M

    2014-07-07

    In this paper we analyze results of Molecular Dynamics simulations of Vickers nanoindentation, performed for sodium borosilicate glasses of interest in the nuclear industry. Three glasses have been studied in their pristine form, as well as a disordered one that is analogous to the real irradiated glass. We focused in the behavior of the glass during the nanoindentation in order to reveal the mechanisms of deformation and how they are affected by microstructural characteristics. Results have shown a strong dependence on the SiO2 content of the glass, which promotes densification due to the open structure of SiO4 tetrahedra and also due to the strength of Si-O bonds. Densification for the glasses is primarily expressed by the relative decrease of the Si-O-Si and Si-O-B angles, indicating rotation of the structural units and decrease of free volume. The increase of alkali content on the other hand results to higher plasticity of the matrix and increased shear flow. The most important effect on the deformation mechanism of the disordered glasses is that of the highly depolymerized network that will also induce shear flow and, in combination with the increased free volume, will result in the decreased hardness of these glasses, as has been previously observed.

  13. Measurement of process-dependent material properties of pharmaceutical solids by nanoindentation.

    PubMed

    Liao, Xiangmin; Wiedmann, Timothy Scott

    2005-01-01

    The purpose of this work was to evaluate nanoindentation as a means to characterize the material properties of pharmaceutical solids. X-ray diffraction of potassium chloride and acetaminophen showed that samples prepared by cooling a melt to a crystalline sample as opposed to slow recrystallization had the same crystal structure. With analysis of the force-displacement curves, the KCl quenched samples had a hardness that was 10 times higher than the recrystallized KCl, while acetaminophen quenched samples were 25% harder than the recrystallized samples. The elastic moduli of the quenched samples were also much greater than that observed for the recrystallized samples. Although the elasticity was independent of load, the hardness increased with load for acetaminophen. With each sample, the flow at constant load increased with applied load. Etching patterns obtained by atomic force microscopy showed that the KCl quenched sample had a higher dislocation density than the recrystallized sample, although there was no evident difference in the acetaminophen samples. Overall, the differences in the observed sample properties may be related to the dislocation density. Thus, nanoindentation has been shown to be a sensitive method for determining a processed-induced change in the hardness, creep, and elasticity of KCl and acetaminophen. (c) 2004 Wiley-Liss, Inc.

  14. Imaging the Material Properties of Bone Specimens using Reflection-Based Infrared Microspectroscopy

    PubMed Central

    Acerbo, Alvin S.; Carr, G. Lawrence; Judex, Stefan; Miller, Lisa M.

    2012-01-01

    Fourier Transform InfraRed Microspectroscopy (FTIRM) is a widely used method for mapping the material properties of bone and other mineralized tissues, including mineralization, crystallinity, carbonate substitution, and collagen cross-linking. This technique is traditionally performed in a transmission-based geometry, which requires the preparation of plastic-embedded thin sections, limiting its functionality. Here, we theoretically and empirically demonstrate the development of reflection-based FTIRM as an alternative to the widely adopted transmission-based FTIRM, which reduces specimen preparation time and broadens the range of specimens that can be imaged. In this study, mature mouse femurs were plastic-embedded and longitudinal sections were cut at a thickness of 4 μm for transmission-based FTIRM measurements. The remaining bone blocks were polished for specular reflectance-based FTIRM measurements on regions immediately adjacent to the transmission sections. Kramers-Kronig analysis of the reflectance data yielded the dielectric response from which the absorption coefficients were directly determined. The reflectance-derived absorbance was validated empirically using the transmission spectra from the thin sections. The spectral assignments for mineralization, carbonate substitution, and collagen cross-linking were indistinguishable in transmission and reflection geometries, while the stoichiometric/non-stoichiometric apatite crystallinity parameter shifted from 1032 / 1021 cm−1 in transmission-based to 1035 / 1025 cm−1 in reflection-based data. This theoretical demonstration and empirical validation of reflection-based FTIRM eliminates the need for thin sections of bone and more readily facilitates direct correlations with other methods such nanoindentation and quantitative backscatter electron imaging (qBSE) from the same specimen. It provides a unique framework for correlating bone’s material and mechanical properties. PMID:22455306

  15. A simple cryogenic holder for tensile testing of soft biological tissues.

    PubMed

    Lepetit, J; Favier, R; Grajales, A; Skjervold, P O

    2004-04-01

    To overcome the difficulty of gripping soft biological materials for tensile test, a simple inexpensive cryogenic holder was developed which allows rapid (3 min) preparation of samples. It is made of 6 parts, built in a bakelite cloth, which is an excellent thermal isolant, and is used with rectangular (8x10(-2)x10(-2)x10(-2)m) samples. The holder with the sample inside is completely immersed in liquid nitrogen for 50 s. This duration allows the freezing of the sample ends on a 10(-2)m length and gives a very flat freezing surface throughout the sample cross section. The 6x10(-2)m central part of the sample remained at ambient temperature. Two parts of the holder help maintain the sample until its ends are vertically gripped in the tensile machine thus avoiding any sample deformation during this step. No pressure was applied on the frozen part of the sample by grips of the tensile machine and this avoids breaks in this region. The sample is fixed by adhesion forces (>1 kN) between its frozen parts and 2 pieces of the holder. The procedure has been successfully tested with bovine and salmon muscle samples and results show tensile breaks randomly distributed in the unfrozen region of the samples. Particular attention has been paid to obtain a very flat freezing surface so that the axial strain is equal throughout the sample and therefore any strain-related mechanical parameters can be accurately determined. The dimensions of the holder can be easily modified to fit other sample geometries and can be used with other biological materials.

  16. CFD analysis of a scramjet combustor with cavity based flame holders

    NASA Astrophysics Data System (ADS)

    Kummitha, Obula Reddy; Pandey, Krishna Murari; Gupta, Rajat

    2018-03-01

    Numerical analysis of a scramjet combustor with different cavity flame holders has been carried out using ANSYS 16 - FLUENT tool. In this research article the internal fluid flow behaviour of the scramjet combustor with different cavity based flame holders have been discussed in detail. Two dimensional Reynolds-Averaged Navier-Stokes governing(RANS) equations and shear stress turbulence (SST) k - ω model along with finite rate/eddy dissipation chemistry turbulence have been considered for modelling chemical reacting flows. Due to the advantage of less computational time, global one step reaction mechanism has been used for combustion modelling of hydrogen and air. The performance of the scramjet combustor with two different cavities namely spherical and step cavity has been compared with the standard DLR scramjet. From the comparison of numerical results, it is found that the development of recirculation regions and additional shock waves from the edge of cavity flame holder is increased. And also it is observed that with the cavity flame holder the residence time of air in the scramjet combustor is also increased and achieved stabilized combustion. From this research analysis, it has been found that the mixing and combustion efficiency of scramjet combustor with step cavity design is optimum as compared to other models.

  17. Sample Holder for Cryogenic Adhesive Shear Test

    NASA Technical Reports Server (NTRS)

    Ledbetter, F. E.; Clemons, J. M.; White, W. T.; Penn, B.; Semmel, M. L.

    1983-01-01

    Five samples tested in one cooldown. Holder mounted in testing machine. Submerged in cryogenic liquid held in cryostat. Movable crosshead of testing machine moves gradually downward. Samples placed under tension, one after another, starting with top one; each sample fails in turn before next is stressed.

  18. Ebola Virus and Marburg Virus in Human Milk Are Inactivated by Holder Pasteurization.

    PubMed

    Hamilton Spence, Erin; Huff, Monica; Shattuck, Karen; Vickers, Amy; Yun, Nadezda; Paessler, Slobodan

    2017-05-01

    Potential donors of human milk are screened for Ebola virus (EBOV) using standard questions, but testing for EBOV and Marburg virus (MARV) is not part of routine serological testing performed by milk banks. Research aim: This study tested the hypothesis that EBOV would be inactivated in donor human milk (DHM) by standard pasteurization techniques (Holder) used in all North American nonprofit milk banks. Milk samples were obtained from a nonprofit milk bank. They were inoculated with EBOV (Zaire strain) and MARV (Angola strain) and processed by standard Holder pasteurization technique. Plaque assays for EBOV and MARV were performed to detect the presence of virus after pasteurization. Neither EBOV nor MARV was detectable by viral plaque assay in DHM or culture media samples, which were pasteurized by the Holder process. EBOV and MARV are safely inactivated in human milk by standard Holder pasteurization technique. Screening for EBOV or MARV beyond questionnaire and self-deferral is not needed to ensure safety of DHM for high-risk infants.

  19. Effects of Document Holder on Postural Neck Muscles Activity among Computer Users: A Preliminary Study.

    PubMed

    Ambusam, Subramaniam; Omar, Baharudin; Joseph, Leonard; Deepashini, Harithasan

    2015-01-01

    Computer users are exposed to work related neck disorders due to repetitive movement and static posture for prolonged period. Viewing document and typing simultaneously are one of the contributing factors for neck disorders. This preliminary study was conducted to evaluate the effects of the document holder on the postural neck muscles activity among computer users. Nine healthy participants with pre-defined inclusion and exclusion criteria were recruited for the study. Neck muscles activity were analyzed using the surface electromyography (EMG) in five different document location such as flat right, flat left, flat center, stand right and stand left during a 5 min typing task. The mean and standard deviation results showed a least amount of muscles activity using a document holder compared to without document holder. Nevertheless, the statistical analysis showed no significant differences between the using of a document holder. The effects of document holder on head excursion and neck muscle activity is recommended in clinical neck pain population.

  20. Nanoindentation testing as a powerful screening tool for assessing phase stability of nanocrystalline high-entropy alloys

    DOE PAGES

    Maier-Kiener, Verena; Schuh, Benjamin; George, Easo P.; ...

    2016-11-19

    The equiatomic high-entropy alloy (HEA), CrMnFeCoNi, has recently been shown to be microstructurally unstable, resulting in a multi-phase microstructure after intermediate-temperature annealing treatments. The decomposition occurs rapidly in the nanocrystalline (NC) state and after longer annealing times in coarse-grained states. To characterize the mechanical properties of differently annealed NC states containing multiple phases, nanoindentation was used in this paper. The results revealed besides drastic changes in hardness, also for the first time significant changes in the Young's modulus and strain rate sensitivity. Finally, nanoindentation of NC HEAs is, therefore, a useful complementary screening tool with high potential as a highmore » throughput approach to detect phase decomposition, which can also be used to qualitatively predict the long-term stability of single-phase HEAs.« less

  1. Note: Rigid holder to host and bend a crystal for multiple volume reflection of a particle beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carassiti, V.; Melchiorri, M.; Dalpiaz, P.

    2010-06-15

    A holder to lodge and bend a silicon crystal to excite multivolume reflection of a high-energy particle beam has been designed and fabricated. A mechanically robust and stable structure fastens a crystal at best condition for experiments. The holder has allowed the observation of 12-time repeated volume reflection with very high efficiency. We detail the most important features behind the construction of the holder together with the characterization of the crystal being bent by the holder.

  2. Preparation of Regular Specimens for Atom Probes

    NASA Technical Reports Server (NTRS)

    Kuhlman, Kim; Wishard, James

    2003-01-01

    A method of preparation of specimens of non-electropolishable materials for analysis by atom probes is being developed as a superior alternative to a prior method. In comparison with the prior method, the present method involves less processing time. Also, whereas the prior method yields irregularly shaped and sized specimens, the present developmental method offers the potential to prepare specimens of regular shape and size. The prior method is called the method of sharp shards because it involves crushing the material of interest and selecting microscopic sharp shards of the material for use as specimens. Each selected shard is oriented with its sharp tip facing away from the tip of a stainless-steel pin and is glued to the tip of the pin by use of silver epoxy. Then the shard is milled by use of a focused ion beam (FIB) to make the shard very thin (relative to its length) and to make its tip sharp enough for atom-probe analysis. The method of sharp shards is extremely time-consuming because the selection of shards must be performed with the help of a microscope, the shards must be positioned on the pins by use of micromanipulators, and the irregularity of size and shape necessitates many hours of FIB milling to sharpen each shard. In the present method, a flat slab of the material of interest (e.g., a polished sample of rock or a coated semiconductor wafer) is mounted in the sample holder of a dicing saw of the type conventionally used to cut individual integrated circuits out of the wafers on which they are fabricated in batches. A saw blade appropriate to the material of interest is selected. The depth of cut and the distance between successive parallel cuts is made such that what is left after the cuts is a series of thin, parallel ridges on a solid base. Then the workpiece is rotated 90 and the pattern of cuts is repeated, leaving behind a square array of square posts on the solid base. The posts can be made regular, long, and thin, as required for samples

  3. 17 CFR 240.14c-3 - Annual report to be furnished security holders.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Notice of Internet Availability of Proxy Materials, annual report to security holders or information... 17 Commodity and Securities Exchanges 3 2011-04-01 2011-04-01 false Annual report to be furnished security holders. 240.14c-3 Section 240.14c-3 Commodity and Securities Exchanges SECURITIES AND EXCHANGE...

  4. 17 CFR 240.14c-3 - Annual report to be furnished security holders.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Notice of Internet Availability of Proxy Materials, annual report to security holders or information... 17 Commodity and Securities Exchanges 3 2012-04-01 2012-04-01 false Annual report to be furnished security holders. 240.14c-3 Section 240.14c-3 Commodity and Securities Exchanges SECURITIES AND EXCHANGE...

  5. 17 CFR 240.14c-3 - Annual report to be furnished security holders.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Notice of Internet Availability of Proxy Materials, annual report to security holders or information... 17 Commodity and Securities Exchanges 4 2014-04-01 2014-04-01 false Annual report to be furnished security holders. 240.14c-3 Section 240.14c-3 Commodity and Securities Exchanges SECURITIES AND EXCHANGE...

  6. 17 CFR 240.14c-3 - Annual report to be furnished security holders.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Notice of Internet Availability of Proxy Materials, annual report to security holders or information... 17 Commodity and Securities Exchanges 3 2013-04-01 2013-04-01 false Annual report to be furnished security holders. 240.14c-3 Section 240.14c-3 Commodity and Securities Exchanges SECURITIES AND EXCHANGE...

  7. Highly identified power-holders feel responsible: The interplay between social identification and social power within groups.

    PubMed

    Scholl, Annika; Sassenberg, Kai; Ellemers, Naomi; Scheepers, Daan; de Wit, Frank

    2018-01-01

    Power relations affect dynamics within groups. Power-holders' decisions not only determine their personal outcomes, but also the outcomes of others in the group that they control. Yet, power-holders often tend to overlook this responsibility to take care of collective interests. The present research investigated how social identification - with the group to which both the powerful and the powerless belong - alters perceived responsibility among power-holders (and the powerless). Combining research on social power and social identity, we argue that power-holders perceive more responsibility than the powerless when strongly (rather than when weakly) identifying with the group. A study among leaders and an experiment supported this, highlighting that although power-holders are often primarily concerned about personal outcomes, they do feel responsible for considering others' interests when these others are included in the (social) self. © 2017 The British Psychological Society.

  8. Spherical nanoindentation study of the deformation micromechanisms of LiTaO{sub 3} single crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anasori, B.; Barsoum, M. W.; Sickafus, K. E.

    2011-07-15

    Herein, spherical nanoindentation (NI) was used to investigate the room temperature deformation behavior of C-plane LiTaO{sub 3} single crystals loaded along the [0001] direction as a function of ion irradiation. When the NI load-displacement curves of 3 different nanoindenter radii (1.4 {mu}m, 5 {mu}m, and 21 {mu}m) were converted to NI stress-strain curves, good agreement between them was found. The surface first deforms elastically - with a Young's modulus of 205 {+-} 5 GPa, calculated from the stiffness versus contact radii curves and 207 {+-} 3 GPa measured using a Berkovich tip - and then plastically deforms at {approx_equal} 6more » GPa. Repeated loading into the same location results in large, reproducible, fully reversible, nested hysteresis loops attributed to the formation of incipient kink bands (IKBs). The latter are coaxial fully reversible dislocation loops that spontaneously shrink when the load is removed. The IKBs most probably nucleate within the (1012) twins that form near the surface. The sharper radii resulted in twin nucleation at lower stresses. The changes in the reversible loops' shape and areas can be related to the width of the twins that form. The latter were proportional to the nanoindenter tip radii and confirmed by scanning electron microscopy and by the fact that larger threshold stresses were needed for IKB nucleation with the smaller tip sizes. No effect of irradiation was observed on the NI response, presumably because of the mildness of the irradiation damage.« less

  9. Novel Concept of Attaching Endoscope Holder to Microscope for Two Handed Endoscopic Tympanoplasty.

    PubMed

    Khan, Mubarak M; Parab, Sapna R

    2016-06-01

    The well established techniques in tympanoplasty are routinely performed with operating microscopes for many decades now. Endoscopic ear surgeries provide minimally invasive approach to the middle ear and evolving new science in the field of otology. The disadvantage of endoscopic ear surgeries is that it is one-handed surgical technique as the non-dominant left hand of the surgeon is utilized for holding and manipulating the endoscope. This necessitated the need for development of the endoscope holder which would allow both hands of surgeon to be free for surgical manipulation and also allow alternate use of microscope during tympanoplasty. To report the preliminary utility of our designed and developed endoscope holder attachment gripping to microscope for two handed technique of endoscopic tympanoplasty. Prospective Non Randomized Clinical Study. Our endoscope holder attachment for microscope was designed and developed to aid in endoscopic ear surgery and to overcome the disadvantage of single handed endoscopic surgery. It was tested for endoscopic Tympanoplasty. The design of the endoscope holder attachment is described in detail along with its manipulation and manoeuvreing. A total of 78 endoholder assisted type 1 endoscopic cartilage tympanoplasties were operated to evaluate its feasibility for the two handed technique and to evaluate the results of endoscopic type 1 cartilage tympanoplasty. In early follow up period ranging from 6 to 20 months, the graft uptake was seen in 76 ears with one residual perforation and 1 recurrent perforations giving a success rate of 97.435 %. Our endocsope holder attachment for gripping microscope is a good option for two handed technique in endoscopic type 1 cartilage tympanoplasty. The study reports the successful application and use of our endoscope holder attachment for gripping microscope in two handed technique of endoscopic type 1 cartilage tympanoplasty and comparable results with microscopic techniques. IV.

  10. 37 CFR 2.59 - Filing substitute specimen(s).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Filing substitute specimen(s..., DEPARTMENT OF COMMERCE RULES OF PRACTICE IN TRADEMARK CASES Drawing § 2.59 Filing substitute specimen(s). (a... specimen(s), the applicant must: (1) For an amendment to allege use under § 2.76, verify by affidavit or...

  11. 7 CFR 762.144 - Repurchase of guaranteed portion from a secondary market holder.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... discrepancy is resolved. (iii) In the case of a request for Agency purchase, the Agency will only pay interest... and the amount due the holder. (ii) Any discrepancy between the amount claimed by the holder and the... approved by the Agency. The Agency will not participate in resolution of any such discrepancy. When there...

  12. NOTE: Monte Carlo simulation of correction factors for IAEA TLD holders

    NASA Astrophysics Data System (ADS)

    Hultqvist, Martha; Fernández-Varea, José M.; Izewska, Joanna

    2010-03-01

    The IAEA standard thermoluminescent dosimeter (TLD) holder has been developed for the IAEA/WHO TLD postal dose program for audits of high-energy photon beams, and it is also employed by the ESTRO-QUALity assurance network (EQUAL) and several national TLD audit networks. Factors correcting for the influence of the holder on the TL signal under reference conditions have been calculated in the present work from Monte Carlo simulations with the PENELOPE code for 60Co γ-rays and 4, 6, 10, 15, 18 and 25 MV photon beams. The simulation results are around 0.2% smaller than measured factors reported in the literature, but well within the combined standard uncertainties. The present study supports the use of the experimentally obtained holder correction factors in the determination of the absorbed dose to water from the TL readings; the factors calculated by means of Monte Carlo simulations may be adopted for the cases where there are no measured data.

  13. Thermal Stress FE Analysis of Large-scale Gas Holder Under Sunshine Temperature Field

    NASA Astrophysics Data System (ADS)

    Li, Jingyu; Yang, Ranxia; Wang, Hehui

    2018-03-01

    The temperature field and thermal stress of Man type gas holder is simulated by using the theory of sunshine temperature field based on ASHRAE clear-sky model and the finite element method. The distribution of surface temperature and thermal stress of gas holder under the given sunshine condition is obtained. The results show that the thermal stress caused by sunshine can be identified as one of the important factors for the failure of local cracked oil leakage which happens on the sunny side before on the shady side. Therefore, it is of great importance to consider the sunshine thermal load in the stress analysis, design and operation of large-scale steel structures such as the gas holder.

  14. Length-Scale Effects and Material Models at Numerical Simulations of Nanoindentation of A Metallic Alloy

    NASA Astrophysics Data System (ADS)

    Nikolov, N.; Avdjieva, T.; Altaparmakov, I.

    2014-06-01

    Some specially designed metallic alloys crystallize during process of rapid quenching which aims their amorphization. Nevertheless, change in their mechanical properties could be seen compared to these obtained during conventional technological regimes of cooling. That attracts the attention in this elaboration. Full 3-D numerical simulations of nanoindentation process of two material models are performed. The models reflect equivalent elastic and different plastic material properties. The plastic behaviour of the first one is subjected to yield criterion of Dracker-Prager and this of the second one to yield criterion of Mises. The reported numerical results depending on the nanoindentation scale length of 1000 nanometers, suggest different adequacy of the two yield criteria to the data obtained experimentally with a Zr-Al-Cu-Ni-Mo alloy. It could be speculated that the different effects developed depending on the indenter travel of 1000 nanometers and taken into account in the two yield criteria stand behind this fact and determinate three structural levels of plastic deformation.

  15. A study of the micro- and nanoscale deformation behavior of individual austenitic dendrites in a FeCrMoVC cast alloy using micro- and nanoindentation experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeisig, J., E-mail: j.zeisig@ifw-dresden.de; Hufenbach, J.; Wendrock, H.

    2016-04-04

    Micro- and nanoindentation experiments were conducted to investigate the deformation mechanisms in a Fe79.4Cr13Mo5V1C1.6 (wt. %) cast alloy. This alloy consists of an as cast microstructure mainly composed of austenite, martensite, and a complex carbide network. During microhardness testing, metastable austenite transforms partially into martensite confirmed by electron backscatter diffraction. For nanoindentation tests, two different indenter geometries were applied (Berkovich and cube corner type). Load-displacement curves of nanoindentation in austenitic dendrites depicted pop-ins after transition into plastic deformation for both nanoindenters. Characterizations of the region beneath a nanoindent by transmission electron microscopy revealed a martensitic transformation as an activated deformationmore » mechanism and suggest a correlation with the pop-in phenomena of the load-displacement curves. Furthermore, due to an inhomogeneous chemical composition within the austenitic dendrites, more stabilized regions deform by mechanical twinning. This additional deformation mechanism was only observed for the cube corner indenter with the sharper geometry since higher shear stresses are induced beneath the contact area.« less

  16. Towards a compact and precise sample holder for macromolecular crystallography.

    PubMed

    Papp, Gergely; Rossi, Christopher; Janocha, Robert; Sorez, Clement; Lopez-Marrero, Marcos; Astruc, Anthony; McCarthy, Andrew; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent

    2017-10-01

    Most of the sample holders currently used in macromolecular crystallography offer limited storage density and poor initial crystal-positioning precision upon mounting on a goniometer. This has now become a limiting factor at high-throughput beamlines, where data collection can be performed in a matter of seconds. Furthermore, this lack of precision limits the potential benefits emerging from automated harvesting systems that could provide crystal-position information which would further enhance alignment at beamlines. This situation provided the motivation for the development of a compact and precise sample holder with corresponding pucks, handling tools and robotic transfer protocols. The development process included four main phases: design, prototype manufacture, testing with a robotic sample changer and validation under real conditions on a beamline. Two sample-holder designs are proposed: NewPin and miniSPINE. They share the same robot gripper and allow the storage of 36 sample holders in uni-puck footprint-style pucks, which represents 252 samples in a dry-shipping dewar commonly used in the field. The pucks are identified with human- and machine-readable codes, as well as with radio-frequency identification (RFID) tags. NewPin offers a crystal-repositioning precision of up to 10 µm but requires a specific goniometer socket. The storage density could reach 64 samples using a special puck designed for fully robotic handling. miniSPINE is less precise but uses a goniometer mount compatible with the current SPINE standard. miniSPINE is proposed for the first implementation of the new standard, since it is easier to integrate at beamlines. An upgraded version of the SPINE sample holder with a corresponding puck named SPINEplus is also proposed in order to offer a homogenous and interoperable system. The project involved several European synchrotrons and industrial companies in the fields of consumables and sample-changer robotics. Manual handling of mini

  17. Position of document holder and work related risk factors for neck pain among computer users: a narrative review.

    PubMed

    Ambusam, S; Baharudin, O; Roslizawati, N; Leonard, J

    2015-01-01

    Document holder is used as a remedy to address occupational neck pain among computer users. An understanding on the effects of the document holder along with other work related risk factors while working in computer workstation requires attention. A comprehensive knowledge on the optimal location of the document holder in computer use and associated work related factors that may contribute to neck pain reviewed in this article. A literature search has been conducted over the past 14 years based on the published articles from January 1990 to January 2014 in both Science Direct and PubMed databases. Medical Subject Headings (MeSH) keywords for search were neck muscle OR head posture OR muscle tension' OR muscle activity OR work related disorders OR neck pain AND/OR document location OR document holder OR source document OR copy screen holder.Document holder placed lateral to the screen was most preferred to reduce neck discomfort among occupational typists. Document without a holder was placed flat on the surface is least preferred. The head posture and muscle activity increases when the document is placed flat on the surface compared to when placed on the document holder. Work related factors such as static posture, repetitive movement, prolong sitting and awkward positions were the risk factors for chronic neck pain. This review highlights the optimal location for document holder for computer users to reduce neck pain. Together, the importance of work related risk factors for to neck pain on occupational typist is emphasized for the clinical management.

  18. Correlation between porosity and space holder content at different sintering temperatures of aluminum foam

    NASA Astrophysics Data System (ADS)

    Rushdi, N. M. F. M.; Jamaludin, S. B.; Mazlee, M. N.; Jamal, Z. A. Z.

    2016-07-01

    Aluminum foam is the most popular metal foam that can be used as energy absorbers, heat exchangers, air-oil separators and structure core of fuel cells. Melt-foaming agent, melt-gas injection, investment casting and powder-foaming agent techniques can be used to manufacture aluminum foam, but these techniques are too expensive. In this study, the aluminum foam was manufactured via a sintering dissolution process (SDP). Powders of aluminum and sodium chloride as space holder (25, 40, 50 wt. %) were mixed together to produce a homogeneous mixture. The mixture was compacted at 200 MPa followed by sintering at 500, 550 and 600˚C for 2 hours. A warm running water stream was used to dissolve the space holder that was embedded in the aluminum. The result showed that, the space holder content performed a significant role to control the total porosity to a value between 18 and 40%, and the porosity increased with increasing content of space holder and sintering temperature.

  19. 7 CFR 4279.78 - Repurchase from holder.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... default not less than 60 days on principal or interest due on the loan; or the lender has failed to remit... holder on the guaranteed loan accruing after 90 days from the date of the demand letter to the lender... repurchase. The lender is encouraged to repurchase the loan to facilitate the accounting of funds, resolve...

  20. 7 CFR 4279.78 - Repurchase from holder.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... default not less than 60 days on principal or interest due on the loan; or the lender has failed to remit... holder on the guaranteed loan accruing after 90 days from the date of the demand letter to the lender... repurchase. The lender is encouraged to repurchase the loan to facilitate the accounting of funds, resolve...

  1. 7 CFR 4279.78 - Repurchase from holder.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... default not less than 60 days on principal or interest due on the loan; or the lender has failed to remit... holder on the guaranteed loan accruing after 90 days from the date of the demand letter to the lender... repurchase. The lender is encouraged to repurchase the loan to facilitate the accounting of funds, resolve...

  2. 19 CFR 10.41b - Clearance of serially numbered substantial holders or outer containers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... or outer containers. 10.41b Section 10.41b Customs Duties U.S. CUSTOMS AND BORDER PROTECTION... holders or outer containers. (a) The holders and containers described in this section may be released... intermodal and similar containers or containers which are themselves vehicles or vehicle appurtenances and...

  3. 19 CFR 10.41b - Clearance of serially numbered substantial holders or outer containers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... or outer containers. 10.41b Section 10.41b Customs Duties U.S. CUSTOMS AND BORDER PROTECTION... holders or outer containers. (a) The holders and containers described in this section may be released... intermodal and similar containers or containers which are themselves vehicles or vehicle appurtenances and...

  4. 19 CFR 10.41b - Clearance of serially numbered substantial holders or outer containers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... or outer containers. 10.41b Section 10.41b Customs Duties U.S. CUSTOMS AND BORDER PROTECTION... holders or outer containers. (a) The holders and containers described in this section may be released... intermodal and similar containers or containers which are themselves vehicles or vehicle appurtenances and...

  5. 19 CFR 10.41b - Clearance of serially numbered substantial holders or outer containers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... or outer containers. 10.41b Section 10.41b Customs Duties U.S. CUSTOMS AND BORDER PROTECTION... holders or outer containers. (a) The holders and containers described in this section may be released... intermodal and similar containers or containers which are themselves vehicles or vehicle appurtenances and...

  6. 19 CFR 10.41b - Clearance of serially numbered substantial holders or outer containers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... or outer containers. 10.41b Section 10.41b Customs Duties U.S. CUSTOMS AND BORDER PROTECTION... holders or outer containers. (a) The holders and containers described in this section may be released... intermodal and similar containers or containers which are themselves vehicles or vehicle appurtenances and...

  7. Indentation Schmid factor and orientation dependence of nanoindentation pop-in behavior of NiAl single crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Tianlei; Gao, Yanfei; Bei, Hongbin

    2011-01-01

    Instrumented nanoindentation techniques have been widely used to characterize the small-scale mechanical behavior of materials. The elastic-plastic transition during nanoindentation is often indicated by a sudden displacement burst (pop-in) in the measured load-displacement curve. In defect-free single crystals, the pop-in is believed to be the result of homogeneous dislocation nucleation because the maximum shear stress corresponding to the pop-in load approaches the theoretical strength of the materials and because the statistical distribution of pop-in stresses is consistent with what is expected for a thermally activated process of homogeneous dislocation nucleation. This paper investigates whether this process is affected by crystallographymore » and stress components other than the resolved shear stress. A Stroh formalism coupled with the two-dimensional Fourier transformation is used to derive the analytical stress fields in elastically anisotropic solids under Hertzian contact, which allows the determination of an indentation Schmid factor, namely, the ratio of maximum resolved shear stress to the maximum contact pressure. Nanoindentation tests were conducted on B2-structured NiAl single crystals with different surface normal directions. This material was chosen because it deforms at room temperature by {110}<001> slip and thus avoids the complexity of partial dislocation nucleation. Good agreement is obtained between the experimental data and the theoretically predicted orientation dependence of pop-in loads based on the indentation Schmid factor. Pop-in load is lowest for indentation directions close to <111> and highest for those close to <001>. In nanoindentation, since the stress component normal to the slip plane is typically comparable in magnitude to the resolved shear stress, we find that the pressure sensitivity of homogeneous dislocation nucleation cannot be determined from pop-in tests. Our statistical measurements generally confirm the

  8. Nanoindentation of Pseudomonas aeruginosa bacterial biofilm using atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Baniasadi, Mahmoud; Xu, Zhe; Gandee, Leah; Du, Yingjie; Lu, Hongbing; Zimmern, Philippe; Minary-Jolandan, Majid

    2014-12-01

    Bacterial biofilms are a source of many chronic infections. Biofilms and their inherent resistance to antibiotics are attributable to a range of health issues including affecting prosthetic implants, hospital-acquired infections, and wound infection. Mechanical properties of biofilm, in particular, at micro- and nano-scales, are governed by microstructures and porosity of the biofilm, which in turn may contribute to their inherent antibiotic resistance. We utilize atomic force microscopy (AFM)-based nanoindentation and finite element simulation to investigate the nanoscale mechanical properties of Pseudomonas aeruginosa bacterial biofilm. This biofilm was derived from human samples and represents a medically relevant model.

  9. Nanoindentation creep behavior of human enamel.

    PubMed

    He, Li-Hong; Swain, Michael V

    2009-11-01

    In this study, the indentation creep behavior of human enamel was investigated with a nanoindentation system and a Berkovich indenter at a force of 250 mN with one-step loading and unloading method. A constant hold period of 900 s was incorporated into each test at the maximum load as well at 5 mN minimum load during unloading. The indentation creep at the maximum load and creep recovery at the minimum load was described with a double exponential function and compared with other classic viscoelastic models (Debye/Maxwell and Kohlrausch-Williams-Watts). Indentation creep rate sensitivity, m, of human enamel was measured for the first time with a value of approximately 0.012. Enamel displayed both viscoelastic and viscoplastic behavior similar to that of bone. These results indicate that, associated with entrapment of particulates between teeth under functional loading and sliding wear conditions, the enamel may inelastically deform but recover upon its release. This behavior may be important in explaining the excellent wear resistance, antifatigue, and crack resistant abilities of natural tooth structure. (c) 2008 Wiley Periodicals, Inc.

  10. Stability of Cortisol and Cortisone in Human Breast Milk During Holder Pasteurization.

    PubMed

    van der Voorn, Bibian; de Waard, Marita; Dijkstra, Lisette R; Heijboer, Annemieke C; Rotteveel, Joost; van Goudoever, Johannes B; Finken, Martijn J J

    2017-12-01

    Human donor milk is the feeding of choice for preterm infants, when own mother's milk is not available. Holder pasteurization is necessary to secure the safety of donor milk, although it can affect milk quality by reduction of nutritional and bioactive components. Recently, research has focused on the potential role of breast milk glucocorticoids for infant development. At this moment, it is unknown whether pasteurization affects milk glucocorticoid levels. Therefore, we assessed whether Holder pasteurization, the most frequently used method nowadays, reduces breast milk cortisol and cortisone levels, using breast milk samples from 30 women who delivered at term. We found tight correlations between pre- and postpasteurization levels of cortisol (R = 0.99) and cortisone (R = 0.98), and good agreement in Passing and Bablok regression analysis. In conclusion, cortisol and cortisone in human term breast milk are not significantly affected by Holder pasteurization.

  11. On capturing the grain-scale elastic and plastic anisotropy of alpha-Ti with spherical nanoindentation and electron back-scattered diffraction

    DOE PAGES

    Weaver, Jordan S.; Priddy, Matthew W.; McDowell, David L.; ...

    2016-09-01

    Here, spherical nanoindentation combined with electron back-scattered diffraction has been employed to characterize the grain-scale elastic and plastic anisotropy of single crystal alpha-Ti of two different compositions (in two different titanium alloys). Data analyses protocols needed to reliably extract the desired properties of interest are extended and demonstrated in this paper. Specifically, the grain-scale mechanical response is extracted in the form of indentation stress-strain curves for commercially pure (CP-Ti) alpha-Ti and alloyed (Ti-64) titanium from measurements on polycrystalline samples. The results are compared with responses of single crystals and nanoindentation tests (hardness and modulus) from the literature, and the measuredmore » indentation moduli are validated using crystal-elastic finite element simulations. The results obtained in this study show that (i) it is possible to characterize reliably the elastic and plastic anisotropy of alpha-Ti (hcp) of varying alloying contents with spherical nanoindentation stress-strain curves, (ii) the indentation modulus of alpha-Ti-64 is 5–10% less than CP-Ti, and (iii) the indentation yield strength of alpha-Ti-64 is 50–80% higher than CP-Ti.« less

  12. Research Amplitudo Vibration On Holder Due To The Process Of Lathe Nozzle Rocket RX 450

    NASA Astrophysics Data System (ADS)

    Ediwan; Budi Djatmiko, Agus; Dody Arisandi, EfFendy; Purnomo, Heri; Ibadi, Mahfud

    2018-04-01

    The main function of the rocket nozzle is to convert the enthalpy efficiency from combustion gas to kinetic energy and also to make high velocity out of the gas. The rocket nozzle usually consists of a converging and diverging part. With a smaller area on the neck and enlarged at the exit area. The velocity flow through the nozzle enlarges into the speed of sound through the neck and then becomes super sonic in the divergent part. Nozzle making or machining using conventional lathes, first performed is drilling on a massive metal that is bonded to the veneer, then after a sufficient gap is done deep-boring. At the time of the process of lathe in the nozzle RX 450 there is an obstacle that is vibrating tool holder chisel or holder so it is worried about not precision of the process of lathe. This should not happen because it can cause failure in the latter for it needs to be studied and studied further so that the lathe process goes accordingly. The holder material of ST 60 with a modulus of elasticity 200 GPa and a nozzle material of AISI 4340 alloy steel with σyield = 470 MPa, Shear Modulus G = 80 GPa. The purpose of this research is to observe the amplitude of vibration on the holder due to RX- 450 nozzle lathe processing for the purpose of amplitude that occurs in accordance with the desired so that the nozzle structure is no damage process. The result of the research was obtained holder with length (L) 80cm, profile width (B) 5 cm, height of profile (H) 10 cm, turning machine ω = 8.98 rad / sec and natural holder frequency ωn = 89.8 rad / second, Amplitude of vibration of δ = 1.21 mm, while the amplitude of the design X = 1.22 mm From the results of this study it can be said that the holder of a chisel or holder can be used as a tool at the time of RX nozzle retrieval process and is quite safe because it works under the condition ω/ω n <0 3 (Plans and Specifications of A Suborbital Rocket Payload "AKPV Engineering University of Wyoming 2009 )

  13. An in vitro study of the microstructure, composition and nanoindentation mechanical properties of remineralizing human dental enamel

    NASA Astrophysics Data System (ADS)

    Arsecularatne, J. A.; Hoffman, M.

    2014-08-01

    This paper describes the results of an in vitro investigation on the interrelations among microstructure, composition and mechanical properties of remineralizing human dental enamel. Polished enamel samples have been demineralized for 10 min in an acetic acid solution (at pH 3) followed by remineralization in human saliva for 30 and 120 min. Microstructure variations of sound, demineralized and remineralized enamel samples have been analysed using focused ion beam, scanning electron microscopy and transmission electron microscopy, while their compositions have been analysed using energy dispersive x-ray. Variations in the mechanical properties of enamel samples have been assessed using nanoindentation. The results reveal that, under the selected conditions, only partial remineralization of the softened enamel surface layer occurs where some pores remain unrepaired. As a result, while the nanoindentation elastic modulus shows an improvement following remineralization, hardness does not.

  14. Sample holder for X-ray diffractometry

    DOEpatents

    Hesch, Victor L.

    1992-01-01

    A sample holder for use with X-ray diffractometers with the capability to rotate the sample, as well as to adjust the position of the sample in the x, y, and z directions. Adjustment in the x direction is accomplished through loosening set screws, moving a platform, and retightening the set screws. Motion translators are used for adjustment in the y and z directions. An electric motor rotates the sample, and receives power from the diffractometer.

  15. 48 CFR 339.7001 - Request for approval to make an award to other than a GSA BPA holder.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... make an award to other than a GSA BPA holder. 339.7001 Section 339.7001 Federal Acquisition Regulations... Services 339.7001 Request for approval to make an award to other than a GSA BPA holder. The Contracting... micro-purchase threshold, that obtaining the required services from a source other than a GSA BPA holder...

  16. 48 CFR 339.7001 - Request for approval to make an award to other than a GSA BPA holder.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... make an award to other than a GSA BPA holder. 339.7001 Section 339.7001 Federal Acquisition Regulations... Services 339.7001 Request for approval to make an award to other than a GSA BPA holder. The Contracting... micro-purchase threshold, that obtaining the required services from a source other than a GSA BPA holder...

  17. 48 CFR 339.7001 - Request for approval to make an award to other than a GSA BPA holder.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... make an award to other than a GSA BPA holder. 339.7001 Section 339.7001 Federal Acquisition Regulations... Services 339.7001 Request for approval to make an award to other than a GSA BPA holder. The Contracting... micro-purchase threshold, that obtaining the required services from a source other than a GSA BPA holder...

  18. 48 CFR 339.7001 - Request for approval to make an award to other than a GSA BPA holder.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... make an award to other than a GSA BPA holder. 339.7001 Section 339.7001 Federal Acquisition Regulations... Services 339.7001 Request for approval to make an award to other than a GSA BPA holder. The Contracting... micro-purchase threshold, that obtaining the required services from a source other than a GSA BPA holder...

  19. 48 CFR 339.7001 - Request for approval to make an award to other than a GSA BPA holder.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... make an award to other than a GSA BPA holder. 339.7001 Section 339.7001 Federal Acquisition Regulations... Services 339.7001 Request for approval to make an award to other than a GSA BPA holder. The Contracting... micro-purchase threshold, that obtaining the required services from a source other than a GSA BPA holder...

  20. Implant image quality in dental radiographs recorded using a customized imaging guide or a standard film holder.

    PubMed

    Schropp, Lars; Stavropoulos, Andreas; Spin-Neto, Rubens; Wenzel, Ann

    2012-01-01

    To compare a customized imaging guide and a standard film holder for obtaining optimally projected intraoral radiographs of dental implants. Intraoral radiographs of four screw-type implants with different inclination placed in an upper or lower dental phantom model were recorded by 32 groups of examiners after a short instruction in the use of the RB-RB/LB-LB mnemonic rule. Half of the examiners recorded the images using a standard film holder and the other half used a customized imaging guide. Each radiograph was assessed under blinded conditions with regard to rendering of the implant threads and was assigned to one of four quality categories: (1) perfect, (2) not perfect, but clinically acceptable, (3) not acceptable, and (4) hopeless. For the upper jaw, the same number of exposures per implant were made to achieve an acceptable image (P=0.86) by the standard film holder method (median=2) and the imaging guide method (median=2). For the lower jaw, medians for the imaging guide method and the film holder method were 1 and 2, respectively (P=0.004). For the imaging guide method, the first exposure was rated as perfect/acceptable in 62% of the cases and for the film holder method in 41% of the cases (P=0.013). After ≤ 2 exposures, 78% (imaging guide method) and 69% (film holder method) of the implant images were perfect/acceptable (P=0.23). The implant inclination did not have a major influence on the outcomes. Perfect or acceptable images were achieved after two exposures with the same frequency either using a customized imaging guide method or a standard film holder method. However, the use of a customized imaging guide method was overall significantly superior to a standard film holder method in terms of obtaining perfect or acceptable images with only one exposure. © 2011 John Wiley & Sons A/S.

  1. 19 CFR 134.25 - Containers or holders for repacked J-list articles and articles incapable of being marked.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Containers or holders for repacked J-list articles... Containers or Holders § 134.25 Containers or holders for repacked J-list articles and articles incapable of...—Repacked J-List Articles and Articles Incapable of Being Marked (Port of entry) I,of, certify that if the...

  2. Nano-indentation and laser-induced damage testing in optical multilayer-dielectric gratings [Nanomechanics and laser-induced damage in optical multilayer dielectric gratings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mehrotra, K.; Corning Research & Development Corp., Coming, NY; Taylor, B. N.

    Here, we demonstrate how a nanomechanical test can be used to generate metrics to complement laser-induced–damage testing (LIDT) measurements and show that differences in optical performance of the gratings (arising from changes in cleaning process and/or fabrication methods) can be related to their mechanical reliability. Data are presented on LIDT measurements in diffractive gratings of silica deposited on optical multilayers. The nano-indentation response of the diffraction gratings is measured in a new mode that allows for the extraction of a measurable metric characterizing the brittleness of the gratings, as well as their ductility. We show that lower LIDT’s are positivelymore » correlated with an increased grating brittleness, and therefore identify a nanomechanical approach to describe LIDT’s. We present extensive numerical simulations of nano-indentation tests and identify different deformation modes including stretching, shear concentration, and bending as precursors to mechanical failure in the nano-indentation test. The effects of geometrical inhomogeneities on enhanced stress generation in these gratings are specifically examined and addressed.« less

  3. Nano-indentation and laser-induced damage testing in optical multilayer-dielectric gratings [Nanomechanics and laser-induced damage in optical multilayer dielectric gratings

    DOE PAGES

    Mehrotra, K.; Corning Research & Development Corp., Coming, NY; Taylor, B. N.; ...

    2017-03-16

    Here, we demonstrate how a nanomechanical test can be used to generate metrics to complement laser-induced–damage testing (LIDT) measurements and show that differences in optical performance of the gratings (arising from changes in cleaning process and/or fabrication methods) can be related to their mechanical reliability. Data are presented on LIDT measurements in diffractive gratings of silica deposited on optical multilayers. The nano-indentation response of the diffraction gratings is measured in a new mode that allows for the extraction of a measurable metric characterizing the brittleness of the gratings, as well as their ductility. We show that lower LIDT’s are positivelymore » correlated with an increased grating brittleness, and therefore identify a nanomechanical approach to describe LIDT’s. We present extensive numerical simulations of nano-indentation tests and identify different deformation modes including stretching, shear concentration, and bending as precursors to mechanical failure in the nano-indentation test. The effects of geometrical inhomogeneities on enhanced stress generation in these gratings are specifically examined and addressed.« less

  4. Microstructure and nanoindentation of the rostrum of Curculio longinasus Chittenden, 1927 (Coleoptera: Curculionidae)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Sudhanshu S.

    2016-08-15

    The rostrum is an extension of the cuticle of the head of weevils (Coleoptera: Curculionidae) and is often used to bore holes for oviposition (the process of laying eggs) into host plant tissue where larval development occurs. In members of the genus Curculio Linnaeus, 1758, the rostrum is long, slender, and strongly curved, but is nevertheless used to excavate straight bore-holes in the fruit of various host plants, through significant deformation of this structure. In this study, scanning electron microscopy (SEM) was used to examine the rostrum of Curculio longinasus Chittenden, 1927, leading to a microstructural model that describes itsmore » deformation behavior. Specifically, we used the continuous stiffness measurement (CSM) technique in nanoindentation to measure the Young's modulus and hardness of rostrum. The values of Young's modulus and hardness for the endocuticle were measured to be 8.91 ± 0.93 GPa and 558 ± 60 MPa, respectively. These results are critical for generating accurate finite element models of the head's mechanical behavior while it undergoes deformation. - Highlights: •SEM was used to examine the rostrum of Curculio longinasus Chittenden, 1927. •Nanoindentation to measure the Young's modulus and hardness of rostrum. •Results are critical for finite element models of the head's mechanical behavior.« less

  5. Transmission Kikuchi diffraction and transmission electron forescatter imaging of electropolished and FIB manufactured TEM specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zieliński, W., E-mail: wiziel@inmat.pw.edu.pl; Płociński, T.; Kurzydłowski, K.J.

    2015-06-15

    We present a study of the efficiency of the utility of scanning electron microscope (SEM)-based transmission methods for characterizing grain structure in thinned bulk metals. Foils of type 316 stainless steel were prepared by two methods commonly used for transmission electron microscopy — double-jet electropolishing and focused ion beam milling. A customized holder allowed positioning of the foils in a configuration appropriate for both transmission electron forward scatter diffraction, and for transmission imaging by the use of a forescatter detector with two diodes. We found that both crystallographic orientation maps and dark-field transmitted images could be obtained for specimens preparedmore » by either method. However, for both methods, preparation-induced artifacts may affect the quality or accuracy of transmission SEM data, especially those acquired by the use of transmission Kikuchi diffraction. Generally, the quality of orientation data was better for specimens prepared by electropolishing, due to the absence of ion-induced damage. - Highlights: • The transmission imaging and diffraction techniques are emerging in scanning electron microscopy (SEM) as promising new field of materials characterization. • The manuscript titled: “Transmission Kikuchi Diffraction and Transmission Electron Forescatter Imaging of Electropolished and FIB Manufactured TEM Specimens” documents how different specimen thinning procedures can effect efficiency of transmission Kikuchi diffraction and transmission electron forescatter imaging. • The abilities to make precision crystallographic orientation maps and dark-field images in transmission was studied on electropolished versus focus ion beam manufactured TEM specimens. • Depending on the need, electropolished and focused ion beam technique may produce suitable specimens for transmission imaging and diffraction in SEM.« less

  6. Hardness evaluation of cured urea-formaldehyde resins with different formaldehyde/urea mole ratios using nanoindentation method

    Treesearch

    Byung-Dae Park; Charles R. Frihart; Yan Yu; Adya P. Singh

    2013-01-01

    To understand the influence of formaldehyde/urea (F/U) mole ratio on the properties of urea–formaldehyde (UF) resins, this study investigated hardness of cured UF resins with different F/U mole ratios using a nanoindentation method. The traditional Brinell hardness (HB) method was also used...

  7. 78 FR 9720 - Agency Information Collection Activities: Holders or Containers Which Enter the United States...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-11

    ... Activities: Holders or Containers Which Enter the United States Duty Free AGENCY: U.S. Customs and Border... or Containers which enter the United States Duty Free. This is a proposed extension of an information..., or other technological techniques or other forms of information. Title: Holders or Containers which...

  8. Book Holder And Page Turner For The Elderly And Handicapped

    NASA Technical Reports Server (NTRS)

    Kerley, James; Eklund, Wayne

    1993-01-01

    Device holds reading matter and facilitates page turning for person not having use of arms and hands. Accommodates variety of publication formats, whether book, magazine, or newspaper. Holder sits on hospital-bed table and adjusted to convenient viewing angle. Includes flat upright back support for reading matter, hinged base, and main bracket with bent-wire page holders. Top support on back extended for such large items as newspapers. Wings on back support extended for oversize materials. Reader turns page by gripping special rod via mouthpiece, applying friction cup at its tip to page, and manipulating rod. Mouthpiece wide and tapered so user grips with teeth and uses jaws to move it, rather than using tongue or lips. Helpful to older people, whose facial and mouth muscles weak.

  9. 30 CFR 14.1 - Purpose, effective date for approval holders.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CONVEYOR BELTS General Provisions § 14.1 Purpose, effective date for approval holders. This Part establishes the flame resistance requirements for MSHA approval of conveyor belts for use in underground coal...

  10. 42 CFR 60.42 - Records, reports, inspection, and audit requirements for HEAL lenders and holders.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OF HEALTH AND HUMAN SERVICES GRANTS HEALTH EDUCATION ASSISTANCE LOAN PROGRAM The Lender and Holder... must maintain for each borrower a payment history showing the date and amount of each payment received... lender or holder must also maintain for each loan a collection history showing the date and subject of...

  11. Understanding pop-ins in spherical nanoindentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pathak, Siddhartha, E-mail: pathak@lanl.gov, E-mail: siddharthapathak@gmail.com; Riesterer, Jessica L.; Michler, Johann

    2014-10-20

    Pop-ins, or sudden displacement-bursts at constant load in a nanoindentation test, are typically attributed to the difficulty of setting up potent dislocation sources in the very small indentation zones in these experiments. Such displacement (and strain) bursts would intuitively indicate a sharp drop in stress during the pop-in event itself. However, spherical indentation stress-strain curves routinely exhibit a high and stable indentation stress value during the pop-in, and the indentation stresses decrease only after a further finite amount of additional indentation displacement has been applied. In order to understand this discrepancy, we utilize a combination of interrupted spherical indentation testsmore » along with depth profiling of the residual indentation surfaces using in-situ atomic force microscopy (AFM) to study pop-ins. The AFM surface profile maps show that there is an asymmetric profile change over a limited region around the indentation contact area for a single pop-in; the asymmetry disappears upon further loading beyond the pop-in. A plausible sequence of physical processes (related to metal plasticity) occurring underneath the indenter during and immediately after the occurrence of the pop-in is proposed to explain these observations.« less

  12. Evaluation of Different Holder Devices for Freeze-Drying in Dual-Chamber Cartridges With a Focus on Energy Transfer.

    PubMed

    Korpus, Christoph; Friess, Wolfgang

    2017-04-01

    For freeze-drying in dual-chamber cartridges, a holder device to enable handling and safe positioning in the freeze-dryer is necessary. The aim of this study was to analyze 4 different types of holder devices and to define the best system based on energy transfer. The main criteria were drying homogeneity, ability to minimize the influence of atypical radiation on product temperatures, and heat transfer effectiveness. The shell holder reduced the influence of atypical radiation by almost 60% compared to a block system and yielded the most homogenous sublimation rates. Besides the most efficient heat transfer with values of 1.58E-4 ± 2.06E-6 cal/(s*cm 2 *K) at 60 mTorr to 3.63E-4 ± 1.85E-5 cal/(s*cm 2 *K) at 200 mTorr for K tot , reaction times to shelf temperature changes were up to 4 times shorter compared to the other holder systems and even faster than for vials. The flexible holder provided a comparable shielding against atypical radiation as the shell but introduced a third barrier against energy transfer. Block and guardrail holder were the least efficient system tested. Hence, the shell holder provided the best radiation shielding, enhanced the transferability of the results to a larger scale, and improved the homogeneity between the dual-chamber cartridges. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  13. 10 CFR 72.160 - Licensee and certificate holder inspection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... WASTE Quality Assurance § 72.160 Licensee and certificate holder inspection. The licensee, applicant for... inspection of activities affecting quality by or for the organization performing the activity to verify.... Examinations, measurements, or tests of material or products processed must be performed for each work...

  14. 10 CFR 72.160 - Licensee and certificate holder inspection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... WASTE Quality Assurance § 72.160 Licensee and certificate holder inspection. The licensee, applicant for... inspection of activities affecting quality by or for the organization performing the activity to verify.... Examinations, measurements, or tests of material or products processed must be performed for each work...

  15. 10 CFR 72.160 - Licensee and certificate holder inspection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... WASTE Quality Assurance § 72.160 Licensee and certificate holder inspection. The licensee, applicant for... inspection of activities affecting quality by or for the organization performing the activity to verify.... Examinations, measurements, or tests of material or products processed must be performed for each work...

  16. 10 CFR 72.160 - Licensee and certificate holder inspection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... WASTE Quality Assurance § 72.160 Licensee and certificate holder inspection. The licensee, applicant for... inspection of activities affecting quality by or for the organization performing the activity to verify.... Examinations, measurements, or tests of material or products processed must be performed for each work...

  17. 10 CFR 72.160 - Licensee and certificate holder inspection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... WASTE Quality Assurance § 72.160 Licensee and certificate holder inspection. The licensee, applicant for... inspection of activities affecting quality by or for the organization performing the activity to verify.... Examinations, measurements, or tests of material or products processed must be performed for each work...

  18. Spherical nanoindentation stress–strain curves

    DOE PAGES

    Pathak, Siddhartha; Kalidindi, Surya R.

    2015-03-24

    Although indentation experiments have long been used to measure the hardness and Young's modulus, the utility of this technique in analyzing the complete elastic–plastic response of materials under contact loading has only been realized in the past few years – mostly due to recent advances in testing equipment and analysis protocols. This paper provides a timely review of the recent progress made in this respect in extracting meaningful indentation stress–strain curves from the raw datasets measured in instrumented spherical nanoindentation experiments. These indentation stress–strain curves have produced highly reliable estimates of the indentation modulus and the indentation yield strength inmore » the sample, as well as certain aspects of their post-yield behavior, and have been critically validated through numerical simulations using finite element models as well as direct in situ scanning electron microscopy (SEM) measurements on micro-pillars. Much of this recent progress was made possible through the introduction of a new measure of indentation strain and the development of new protocols to locate the effective zero-point of initial contact between the indenter and the sample in the measured datasets. As a result, this has led to an important key advance in this field where it is now possible to reliably identify and analyze the initial loading segment in the indentation experiments.« less

  19. Contact mechanics at nanometric scale using nanoindentation technique for brittle and ductile materials.

    PubMed

    Roa, J J; Rayon, E; Morales, M; Segarra, M

    2012-06-01

    In the last years, Nanoindentation or Instrumented Indentation Technique has become a powerful tool to study the mechanical properties at micro/nanometric scale (commonly known as hardness, elastic modulus and the stress-strain curve). In this review, the different contact mechanisms (elastic and elasto-plastic) are discussed, the recent patents for each mechanism (elastic and elasto-plastic) are summarized in detail, and the basic equations employed to know the mechanical behaviour for brittle and ductile materials are described.

  20. In situ SEM Observation of Column-like and Foam-like CNT Array Nanoindentation

    DTIC Science & Technology

    2011-03-02

    frompyrolization of iron(II) phthalocyanine , producing vertically aligned CNTs with a nominal outer diameter of 50 nm.11,12 The array was indented using a 40 40 μm...www.acsami.org In situ SEM Observation of Column-like and Foam-like CNT Array Nanoindentation Matthew R. Maschmann,†,‡Qiuhong Zhang,†,§ Robert Wheeler...multiple length scales. Their behavior is expected to rely heavily on the properties of individual constituent CNTs , interactions and load distribution

  1. 42 CFR 60.42 - Records, reports, inspection, and audit requirements for HEAL lenders and holders.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Records, reports, inspection, and audit requirements for HEAL lenders and holders. 60.42 Section 60.42 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS HEALTH EDUCATION ASSISTANCE LOAN PROGRAM The Lender and Holder § 60.42 Records, reports, inspection, and audit...

  2. 21 CFR 892.1880 - Wall-mounted radiographic cassette holder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wall-mounted radiographic cassette holder. 892.1880 Section 892.1880 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1880 Wall-mounted...

  3. 51. (no plate) Lens, lens pedestal, mercury float, shade holder ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. (no plate) Lens, lens pedestal, mercury float, shade holder installation, drawing # 3101, sheet 2 of 2. Approved April 6, 1928. - Block Island Southeast Light, Spring Street & Mohegan Trail at Mohegan Bluffs, New Shoreham, Washington County, RI

  4. Oxide Dissolution and Oxygen Diffusion in Solid-State Recycled Ti-6Al-4V: Numerical Modeling, Verification by Nanoindentation, and Effects on Grain Growth and Recrystallization

    NASA Astrophysics Data System (ADS)

    Lui, E. W.; Palanisamy, S.; Dargusch, M. S.; Xia, K.

    2017-12-01

    The oxide dissolution and oxygen diffusion during annealing of Ti-6Al-4V solid-state recycled from machining chips by equal-channel angular pressing (ECAP) have been investigated using nanoindentation and numerical modeling. The hardness profile from nanoindentation was converted into the oxygen concentration distribution using the Fleisher and Friedel model. An iterative fitting method was then employed to revise the ideal model proposed previously, leading to correct predictions of the oxide dissolution times and oxygen concentration profiles and verifying nanoindentation as an effective method to measure local oxygen concentrations. Recrystallization started at the prior oxide boundaries where local strains were high from the severe plastic deformation incurred in the ECAP recycling process, forming a band of ultrafine grains whose growth was retarded by solute dragging thanks to high oxygen concentrations. The recrystallized fine-grained region would advance with time to eventually replace the lamellar structure formed during ECAP.

  5. Towards the modeling of nanoindentation of virus shells: Do substrate adhesion and geometry matter?

    NASA Astrophysics Data System (ADS)

    Bousquet, Arthur; Dragnea, Bogdan; Tayachi, Manel; Temam, Roger

    2016-12-01

    Soft nanoparticles adsorbing at surfaces undergo deformation and buildup of elastic strain as a consequence of interfacial adhesion of similar magnitude with constitutive interactions. An example is the adsorption of virus particles at surfaces, a phenomenon of central importance for experiments in virus nanoindentation and for understanding of virus entry. The influence of adhesion forces and substrate corrugation on the mechanical response to indentation has not been studied. This is somewhat surprising considering that many single-stranded RNA icosahedral viruses are organized by soft intermolecular interactions while relatively strong adhesion forces are required for virus immobilization for nanoindentation. This article presents numerical simulations via finite elements discretization investigating the deformation of a thick shell in the context of slow evolution linear elasticity and in presence of adhesion interactions with the substrate. We study the influence of the adhesion forces in the deformation of the virus model under axial compression on a flat substrate by comparing the force-displacement curves for a shell having elastic constants relevant to virus capsids with and without adhesion forces derived from the Lennard-Jones potential. Finally, we study the influence of the geometry of the substrate in two-dimensions by comparing deformation of the virus model adsorbed at the cusp between two cylinders with that on a flat surface.

  6. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Neurosurgical head holder (skull clamp). 882.4460 Section 882.4460 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4460 Neurosurgical head...

  7. Mechanical Degradation of Porous NiTi Alloys Under Static and Cyclic Loading

    NASA Astrophysics Data System (ADS)

    Hosseini, Seyyed Alireza

    2017-12-01

    Pore characteristics and morphology have significant effect on mechanical behavior of porous NiTi specimens. In this research, porous NiTi with different pore sizes, shapes and morphology were produced by powder metallurgy methods using space-holder materials. The effect of the pore characteristics on the mechanical properties was investigated by static and cyclic compression tests at body temperature. The results show that specimens with low porosity and isolated pores exhibit more mechanical strength and recoverable strain. The specimen with 36% porosity produced without space holder could preserve its properties up to 10% strain and its strain recovery was complete after cyclic compression tests. On the other hand, the specimens produced by a urea space holder with more than 60% interconnected porosity show rapid degradation of their scaffolds. The highly porous specimens degraded even below 5% strain due to crack formation and propagation in the thin pore walls. For highly porous specimens produced by a NaCl space holder, the pores are partially interconnected with a cubic shape; nevertheless, their mechanical behavior is close to low-porosity specimens.

  8. 31 CFR 212.7 - Notice to the account holder.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Notice to the account holder. 212.7 Section 212.7 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) FISCAL... readily understandable language. (1) Means of contacting a local free attorney or legal aid service. (2...

  9. Surface crystalline phases and nanoindentation hardness of explanted zirconia femoral heads.

    PubMed

    Catledge, Shane A; Cook, Monique; Vohra, Yogesh K; Santos, Erick M; McClenny, Michelle D; David Moore, K

    2003-10-01

    One new and nine explanted zirconia femoral heads were studied using glancing angle X-ray diffraction, scanning electron microscopy, and nanoindentation hardness techniques. All starting zirconia implants consisted only of tetragonal zirconia polycrystals (TZP). For comparison, one explanted alumina femoral head was also studied. Evidence for a surface tetragonal-to-monoclinic zirconia phase transformation was observed in some implants, the extent of which was varied for different in-service conditions. A strong correlation was found between increasing transformation to the monoclinic phase and decreasing surface hardness. Microscopic investigations of some of the explanted femoral heads revealed ultra high molecular weight polyethylene and metallic transfer wear debris.

  10. Positron and nanoindentation study of helium implanted high chromium ODS steels

    NASA Astrophysics Data System (ADS)

    Veternikova, Jana Simeg; Fides, Martin; Degmova, Jarmila; Sojak, Stanislav; Petriska, Martin; Slugen, Vladimir

    2017-12-01

    Three oxide dispersion strengthened (ODS) steels with different chromium content (MA 956, MA 957 and ODM 751) were studied as candidate materials for new nuclear reactors in term of their radiation stability. The radiation damage was experimentally simulated by helium ion implantation with energy of ions up to 500 keV. The study was focused on surface and sub-surface structural change due to the ion implantation observed by mostly non-destructive techniques: positron annihilation lifetime spectroscopy and nanoindentation. The applied techniques demonstrated the best radiation stability of the steel ODM 751. Blistering effect occurred due to high implantation dose (mostly in MA 956) was studied in details.

  11. A correlation between micro- and nano-indentation on materials irradiated by high-energy heavy ions

    NASA Astrophysics Data System (ADS)

    Yang, Yitao; Zhang, Chonghong; Ding, Zhaonan; Su, Changhao; Yan, Tingxing; Song, Yin; Cheng, Yuguang

    2018-01-01

    Hardness testing is an efficient means of assessing the mechanical properties of materials due to the small sampling volume requirement. Previous studies have established the correlation between flow stress and Vickers hardness. However, the damage layer produced by ions irradiation with low energy is too thin to perform Vickers hardness test, which is usually measured by nano-indentation. Therefore, it is necessary to correlate the Vickers hardness and nano-hardness for the convenience of assessing mechanical properties of materials under irradiation. In this study, various materials (pure nickel, nickel base alloys and oxide dispersion strengthened steel) were irradiated with high-energy heavy ions to different damage levels. After irradiation, micro- and nano-indentation were performed to characterize the change in hardness. Due to indentation size effect (ISE), the hardness was dependent of load or depth. Therefore, Nix-Gao model was used to obtain the hardness without ISE (Hv0 and Hnano_0). The determined Hv0 was plotted as a function of the corresponding Hnano_0, then a good linear relation was found between Vickers hardness and nano-hardness, and a coefficient was determined to be 81.0 ± 10.5, namely, Hv 0 = 81.0Hnano _ 0 (Hv0 with unit of kgf/mm2, Hnano_0 with unit of GPa). This correlation was based on the data from various materials, therefore it was independent of materials. Based on the established correlation and nano-indentation results, the change fraction in yield stress of Inconel 718 and pure Ni with ion irradiation was compared with that with neutron irradiation. The data of Inconel 718 with heavy ion irradiation was in good agreement with the data with neutron irradiation, which was a good demonstration for the validation of the established correlation. However, a distinctive difference in change fraction of yield stress was seen for pure Ni under heavy ion irradiation and neutron irradiation, which was attributed to the difference in samples

  12. A SIMPLE TUMBLING DEVICE USED IN PREPARING ALGAL SPECIMENS FOR ELECTRON MICROSCOPY.

    PubMed

    Berlagnolli, B L; Nadakavukaren, M J

    1969-06-01

    Screw cap vials are held in a wooden holder which rotates at a 90° angle to the horizontal. The. shaft of a small electric motor with built-in gear box is attached perpendicularly to the wooden vial holder via a hole drilled in the center of the wooden holder. The rotation of the vial holder is about 6 rpm. This motion ensures a thorough tumbling of the contents of the vials. Even viscous embedding media are kept in constant agitation, which provides for superior penetration of the tissue. Tumbling devices to hold a range of vial sizes can be constructed with a minimum of labor at a cost of $10-20 each.

  13. 15. VIEW OF DUMMY FUEL ELEMENT ON FUEL ELEMENT HOLDER. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. VIEW OF DUMMY FUEL ELEMENT ON FUEL ELEMENT HOLDER. SHOWS AIR FORCE MAN AT EDGE OF TANK. INEL PHOTO NUMBER 65-6176, TAKEN NOVEMBER 10, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  14. Understanding pop-ins in spherical nanoindentation

    DOE PAGES

    Pathak, Siddhartha; Riesterer, Jessica L.; Kalidindi, Surya R.; ...

    2014-10-24

    In this study, pop-ins, or sudden displacement-bursts at constant load in a nanoindentation test, are typically attributed to the difficulty of setting up potent dislocation sources in the very small indentation zones in these experiments. Such displacement (and strain) bursts would intuitively indicate a sharp drop in stress during the pop-in event itself. However, spherical indentation stress-strain curves routinely exhibit a high and stable indentation stress value during the pop-in, and the indentation stresses decrease only after a further finite amount of additional indentation displacement has been applied. In order to understand this discrepancy, we utilize a combination of interruptedmore » spherical indentation tests along with depth profiling of the residual indentation surfaces using in-situ atomic force microscopy (AFM) to study pop-ins. The AFM surface profile maps show that there is an asymmetric profile change over a limited region around the indentation contact area for a single pop-in; the asymmetry disappears upon further loading beyond the pop-in. A plausible sequence of physical processes (related to metal plasticity) occurring underneath the indenter during and immediately after the occurrence of the pop-in is proposed to explain these observations.« less

  15. Scholarly Productivity in Developing Countries: An Analysis of Levels and Patterns among Doctoral Holders in Uganda

    ERIC Educational Resources Information Center

    Wamala, Robert; Ssembatya, Vincent A.

    2013-01-01

    Doctoral holders are considered to be key actors in the creation of innovation and knowledge. However, this generalization may not hold true for doctoral holders in all countries. This study sought to assess the scholarly productivity of these highly qualified individuals in Uganda. The investigation is based on data sourced from the 2012 Careers…

  16. 17 CFR 240.14a-7 - Obligations of registrants to provide a list of, or mail soliciting material to, security holders.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., form of proxy or other communication to such holders, including to the extent known or reasonably... provided for under applicable state law identifying the proposal or other corporate action that will be the subject of the security holder's solicitation or communication and attesting that: (i) The security holder...

  17. Micromechanical characterization of shales through nanoindentation and energy dispersive x-ray spectrometry

    DOE PAGES

    Veytskin, Yuriy B.; Tammina, Vamsi K.; Bobko, Christopher P.; ...

    2017-03-01

    Shales are heterogeneous sedimentary rocks which typically comprise a variable mineralogy (including compacted clay particles sub-micrometer in size), silt grains, and nanometer sized pores collectively arranged with transversely isotropic symmetry. Moreover, a detailed understanding of the micro- and sub-microscale geomechanics of these minerals is required to improve models of shale strength and stiffness properties. In this paper, we propose a linked experimental–computational approach and validate a combination of grid nanoindentation and Scanning Electron Microscopy (SEM) with Energy and Wavelength Dispersive X-ray Spectrometry (EDS/WDS) at the same spatial locations to identify both the nano-mechanical morphology and local mineralogy of these nanocomposites.more » The experimental parameters of each method are chosen to assess a similar volume of material. By considering three different shales of varying mineralogy and mechanical diversity, we show through the EMMIX statistical iterative technique that the constituent phases, including highly compacted plate- or sheet-like clay particles, carbonates, silicates, and sulfides, have distinct nano-mechanical morphologies and associated indentation moduli and hardness. Nanoindentation-based strength homogenization analysis determines an average clay packing density, friction coefficient, and solid cohesion for each tested shale sample. Comparison of bulk to microscale geomechanical properties, through bulk porosimetry measurements, reveals a close correspondence between bulk and microscale clay packing densities. Determining the mechanical microstructure and material properties is useful for predictive microporomechanical models of the stiffness and strength properties of shale. Furthermore, the experimental and computational approaches presented here also apply to other chemically and mechanically complex materials exhibiting nanogranular, composite behavior.« less

  18. Effects of coating materials on nanoindentation hardness of enamel and adjacent areas.

    PubMed

    Alsayed, Ehab Z; Hariri, Ilnaz; Nakashima, Syozi; Shimada, Yasushi; Bakhsh, Turki A; Tagami, Junji; Sadr, Alireza

    2016-06-01

    Materials that can be applied as thin coatings and actively release fluoride or other bioavailable ions for reinforcing dental hard tissue deserve further investigation. In this study we assessed the potential of resin coating materials in protection of underlying and adjacent enamel against demineralization challenge using nanoindentation. Enamel was coated using Giomer (PRG Barrier Coat, PBC), resin-modified glass-ionomer (Clinpro XT Varnish, CXT), two-step self-etch adhesive (Clearfil SE Protect, SEP) or no coating (control). After 5000 thermal cycles and one-week demineralization challenge, Martens hardness of enamel beneath the coating, uncoated area and intermediate areas was measured using a Berkovich tip under 2mN load up to 200μm depth. Integrated hardness and 10-μm surface zone hardness were compared among groups. Nanoindentation and scanning electron microscopy suggested that all materials effectively prevented demineralization in coated area. Uncoated areas presented different hardness trends; PBC showed a remarkable peak at the surface zone before reaching as low as the control, while CXT showed relatively high hardness values at all depths. Ion-release from coating materials affects different layers of enamel. Coatings with fluoride-releasing glass fillers contributed to reinforcement of adjacent enamel. Surface prereacted glass filler-containing PBC superficially protected neighboring enamel against demineralization, while resin-modified glass-ionomer with calcium (CXT) improved in-depth protection. Cross-sectional hardness mapping of enamel on a wide range of locations revealed minute differences in its structure. Copyright © 2016 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  19. Effect of tip radius on the incipient plasticity of chromium studied by nanoindentation

    DOE PAGES

    Wu, Dong; Morris, James R.; Nieh, T. G.

    2014-10-01

    The onset of plasticity in Cr was investigated by nanoindentation using indenters with tip radii ranging from 60 to 759 nm. The stress for incipient plasticity was found to increase with decreasing tip radius. We find that the cumulative pop-in probability on load could be described successfully by a combined model over the full range of tip radius, indicating that the incipient plasticity might be triggered either by the homogeneous nucleation of dislocation or by the activation of existing dislocations underneath the indenter.

  20. Direct observation of twin deformation in YBa2Cu3O7-x thin films by in situ nanoindentation in TEM

    NASA Astrophysics Data System (ADS)

    Lee, Joon Hwan; Zhang, Xinghang; Wang, Haiyan

    2011-04-01

    The deformation behaviors of YBa2Cu3O7-x (YBCO) thin films with twinning structures were studied via in situ nanoindentation experiments in a transmission electron microscope. The YBCO films were grown on SrTiO3 (001) substrates by pulsed laser deposition. Both ex situ (conventional) and in situ nanoindentation were conducted to reveal the deformation of the YBCO films from the directions perpendicular and parallel to the twin interfaces. The hardness measured perpendicular to the twin interfaces is ˜50% and 40% higher than that measured parallel to the twin interfaces ex situ and in situ, respectively. Detailed in situ movie analysis reveals that the twin structures play an important role in deformation and strengthening mechanisms in YBCO thin films.

  1. Further improvement of an intraocular lens holder for more physiological measurements within a mechanical eye model

    NASA Astrophysics Data System (ADS)

    Reutterer, Bernd; Traxler, Lukas; Bayer, Natascha; Drauschke, Andreas

    2017-04-01

    To evaluate the performance of intraocular lenses to treat cataract, an optomechanical eye model was developed. One of the most crucial components is the IOL holder, which should guarantee a physiological representation of the capsular bag and a stable position during measurement sequences. Individual holders are required due to the fact that every IOL has different geometric parameters. A method which allows obtaining the correct dimensions for the holder of a special IOL was developed and tested, by verifying the position of the IOL before and after a measurement sequence. Results of telecentric measurements and MTF measurements show that the IOL position does not change during the displacement sequence induced by the stepper motors of the eye model.

  2. Foot-controlled robotic-enabled endoscope holder for endoscopic sinus surgery: A cadaveric feasibility study.

    PubMed

    Chan, Jason Y K; Leung, Iris; Navarro-Alarcon, David; Lin, Weiyang; Li, Peng; Lee, Dennis L Y; Liu, Yun-hui; Tong, Michael C F

    2016-03-01

    To evaluate the feasibility of a unique prototype foot-controlled robotic-enabled endoscope holder (FREE) in functional endoscopic sinus surgery. Cadaveric study. Using human cadavers, we investigated the feasibility, advantages, and disadvantages of the robotic endoscope holder in performing endoscopic sinus surgery with two hands in five cadaver heads, mimicking a single nostril three-handed technique. The FREE robot is relatively easy to use. Setup was quick, taking less than 3 minutes from docking the robot at the head of the bed to visualizing the middle meatus. The unit is also relatively small, takes up little space, and currently has four degrees of freedom. The learning curve for using the foot control was short. The use of both hands was not hindered by the presence of the endoscope in the nasal cavity. The tremor filtration also aided in the smooth movement of the endoscope, with minimal collisions. The FREE endoscope holder in an ex-vivo cadaver test corroborated the feasibility of the robotic prototype, which allows for a two-handed approach to surgery equal to a single nostril three-handed technique without the holder that may reduce operating time. Further studies will be needed to evaluate its safety profile and use in other areas of endoscopic surgery. NA. Laryngoscope, 126:566-569, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  3. Proposal of a Budget-Friendly Camera Holder for Endoscopic Ear Surgery.

    PubMed

    Ozturan, Orhan; Yenigun, Alper; Aksoy, Fadlullah; Ertas, Burak

    2018-01-01

    Endoscopic ear surgery (EES) is increasingly a preferred technique in otologic society. It offers excellent visualization of the anatomical structures directly and behind the corners with variable angled telescopes. It also provides reduced operative morbidity due to being able to perform surgical interventions with less invasive approaches. Operative preparation and setup time and cost of endoscopy system are less expensive compared with surgical microscopes. On the other hand, the main disadvantage of EES is that the surgery has to be performed with 1 single hand. It is certainly restrictive for an ear surgeon who has been operating with 2 hands under otologic microscopic views for years and certainly requires a learning period and perseverance. Holding the endoscope by a second surgeon is not executable because of insufficient surgical space.Endoscope/camera holders have been developed for those who need the comfort and convenience afforded by double-handed microscopic ear surgery. An ideal endoscope holder should be easy-to-set up, easily controlled, providing a variety of angled views, allowing the surgeon to operate with 2 hands and, budget-friendly. In this article, a commercially available 11-inch magic arm camera holder is proposed by the authors to be used in EES due to its versatile, convenient, and budget-friendly features. It allows 2-handed EES through existing technology and is affordable for surgeons looking for a low-cost and practical solution.

  4. 78 FR 48456 - Notice of Cancellation of Customs Broker Licenses Due to Death of the License Holder

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-08

    ... Customs Broker Licenses Due to Death of the License Holder AGENCY: U.S. Customs and Border Protection, Department of Homeland Security. ACTION: Customs broker license cancellation due to death of the broker... without prejudice due to the death of the license holders. SUPPLEMENTARY INFORMATION: Notice is hereby...

  5. Bacteria and Bioactivity in Holder Pasteurized and Shelf-Stable Human Milk Products

    PubMed Central

    2017-01-01

    Abstract Background: Historically, Holder pasteurization has been used to pasteurize donor human milk available in a hospital setting. There is extensive research that provides an overview of the impact of Holder pasteurization on bioactive components of human milk. A shelf-stable (SS) human milk product, created using retort processing, recently became available; however, to our knowledge, little has been published about the effect of retort processing on human milk. Objective: We aimed to assess the ability of retort processing to eliminate bacteria and to quantify the difference in lysozyme and secretory immunoglobulin A (sIgA) activity between Holder pasteurized (HP) and SS human milk. Methods: Milk samples from 60 mothers were pooled. From this pool, 36 samples were taken: 12 samples were kept raw, 12 samples were HP, and 12 samples were retort processed to create an SS product. All samples were analyzed for total aerobic bacteria, coliform bacteria, Bacillus cereus, sIgA activity, and lysozyme activity. Raw samples served as the control. Results: One raw sample and 3 HP samples contained B. cereus at the time of culture. There were no detectable bacteria in SS samples at the time of culture. Raw samples had significantly greater lysozyme and sIgA activity than HP and SS samples (P < 0.0001). HP samples retained significantly more lysozyme and sIgA activity (54% and 87%, respectively) than SS samples (0% and 11%, respectively). Conclusions: Human milk processed using Holder pasteurization should continue to be screened for the presence of B. cereus. Clinicians should be aware of the differences in the retention of lysozyme and sIgA activity in HP and SS products when making feeding decisions for medically fragile or immunocompromised infants to ensure that patients are receiving the maximum immune protection. PMID:29955718

  6. Holder and Topic Based Analysis of Emotions on Blog Texts: A Case Study for Bengali

    NASA Astrophysics Data System (ADS)

    Das, Dipankar; Bandyopadhyay, Sivaji

    The paper presents an extended approach of analyzing emotions of the blog users on different topics. The rule based techniques to identify emotion holders and topics with respect to their corresponding emotional expressions helps to develop the baseline system. On the other hand, the Support Vector Machine (SVM) based supervised framework identifies the holders, topics and emotional expressions from the blog sentences by outperforming the baseline system. The existence of many to many relations between the holders and the topics with respect to Ekman's six different emotion classes has been examined using two way evaluation techniques, one is with respect to holder and other is from the perspective of topic. The results of the system were found satisfactory in comparison with the agreement of the subjective annotation. The error analysis shows that the topic of a blog at document level is not always conveyed at the sentence level. Moreover, the difficulty in identifying topic from a blog document is due to the problem of identifying some features like bigrams, Named Entities and sentiment. Thus, we employed a semantic clustering approach along with these features to identify the similarity between document level topic and sentential topic as well as to improve the results of identifying the document level topic.

  7. A hybrid approach to determining cornea mechanical properties in vivo using a combination of nano-indentation and inverse finite element analysis.

    PubMed

    Abyaneh, M H; Wildman, R D; Ashcroft, I A; Ruiz, P D

    2013-11-01

    An analysis of the material properties of porcine corneas has been performed. A simple stress relaxation test was performed to determine the viscoelastic properties and a rheological model was built based on the Generalized Maxwell (GM) approach. A validation experiment using nano-indentation showed that an isotropic GM model was insufficient for describing the corneal material behaviour when exposed to a complex stress state. A new technique was proposed for determining the properties, using a combination of nano-indentation experiment, an isotropic and orthotropic GM model and inverse finite element method. The good agreement using this method suggests that this is a promising technique for measuring material properties in vivo and further work should focus on the reliability of the approach in practice. © 2013 Elsevier Ltd. All rights reserved.

  8. Nanoindentation and thermal characterization of poly (vinylidenefluoride)/MWCNT nanocomposites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eggedi, Obulapathi; Valiyaneerilakkal, Uvais; Varghese, Soney, E-mail: soneyva@nitc.ac.in

    2014-04-15

    We report the preparation, thermal and micro/nanomechanical behavior of poly (vinylidine diflouride) (PVDF)/multiwalled carbon nanotube (MWCNT) nanocomposites. It has been found that the addition of MWCNT considerably enhances the β-phase formation, thermal and mechanical properties of PVDF. Atomic force microscope (AFM) studies have been performed on the composites under stress conditions to measure the mechanical properties. The nanoscale mechanical properties of the composites like Young's modulus and hardness of the nanocomposites were investigated by nanoindentation technique. Morphological studies of the nanocomposites were also studied, observations show a uniform distribution of MWCNT in the matrix and interfacial adhesion between PVDF andmore » MWCNT was achieved, which was responsible for enhancement in the hardness and Young's modulus. Differential scanning calorimetry (DSC) studies indicate that the melting temperature of the composites have been slightly increased while the heat of fusion markedly decreased with increasing MWCNT content.« less

  9. Nanoindentation near the edge

    Treesearch

    J.E. Jakes; C.R. Frihart; J.F. Beecher; R.J. Moon; P.J. Resto; Z.H. Melgarejo; O.M. Saurez; H. Baumgart; A.A. Elmustafa; D.S. Stone

    2009-01-01

    Whenever a nanoindent is placed near an edge, such as the free edge of the specimen or heterophase interface intersecting the surface, the elastic discontinuity associated with the edge produces artifacts in the load-depth data. Unless properly handled in the data analysis, the artifacts can produce spurious results that obscure any real trends in properties as...

  10. Virtual Specimens

    NASA Astrophysics Data System (ADS)

    de Paor, D. G.

    2009-12-01

    Virtual Field Trips have been around almost as long as the Worldwide Web itself yet virtual explorers do not generally return to their desktops with folders full of virtual hand specimens. Collection of real specimens on fields trips for later analysis in the lab (or at least in the pub) has been an important part of classical field geoscience education and research for generations but concern for the landscape and for preservation of key outcrops from wanton destruction has lead to many restrictions. One of the author’s favorite outcrops was recently vandalized presumably by a geologist who felt the need to bash some of the world’s most spectacular buckle folds with a rock sledge. It is not surprising, therefore, that geologists sometimes leave fragile localities out of field trip itineraries. Once analyzed, most specimens repose in drawers or bins, never to be seen again. Some end up in teaching collections but recent pedagogical research shows that undergraduate students have difficulty relating specimens both to their collection location and ultimate provenance in the lithosphere. Virtual specimens can be created using 3D modeling software and imported into virtual globes such as Google Earth (GE) where, they may be linked to virtual field trip stops or restored to their source localities on the paleo-globe. Sensitive localities may be protected by placemark approximation. The GE application program interface (API) has a distinct advantage over the stand-alone GE application when it comes to viewing and manipulating virtual specimens. When instances of the virtual globe are embedded in web pages using the GE plug-in, Collada models of specimens can be manipulated with javascript controls residing in the enclosing HTML, permitting specimens to be magnified, rotated in 3D, and sliced. Associated analytical data may be linked into javascript and localities for comparison at various points on the globe referenced by ‘fetching’ KML. Virtual specimens open up

  11. Shape-memory NiTi foams produced by replication of NaCl space-holders.

    PubMed

    Bansiddhi, A; Dunand, D C

    2008-11-01

    NiTi foams were created with a structure (32-36% open pores 70-400 microm in size) and mechanical properties (4-25 GPa stiffness, >1000 MPa compressive strength, >42% compressive ductility, and shape-memory strains up to 4%) useful for bone implant applications. A mixture of NiTi and NaCl powders was hot-isostatically pressed at 950 and 1065 degrees C and the NaCl phase was then dissolved in water. The resulting NiTi foams show interconnected pores that replicate the shape and size of the NaCl powders, indicating that NiTi powders densified significantly before NaCl melted at 801 degrees C. Densifying NiTi or other metal powders above the melting point of the space-holder permits the use of NaCl, with the following advantages compared with higher-melting, solid space-holders such as oxides and fluorides used to date: (i) no temperature limit for densification; (ii) lower cost; (iii) greater flexibility in powder (and thus pore) shape; (iv) faster dissolution; (v) reduced metal corrosion during dissolution; (vi) lower toxicity if space-holder residues remain in the foam.

  12. OMNY PIN—A versatile sample holder for tomographic measurements at room and cryogenic temperatures

    NASA Astrophysics Data System (ADS)

    Holler, M.; Raabe, J.; Wepf, R.; Shahmoradian, S. H.; Diaz, A.; Sarafimov, B.; Lachat, T.; Walther, H.; Vitins, M.

    2017-11-01

    Nowadays ptychographic tomography in the hard x-ray regime, i.e., at energies above about 2 keV, is a well-established measurement technique. At the Paul Scherrer Institut, currently two instruments are available: one is measuring at room temperature and atmospheric pressure, and the other, the so-called OMNY (tOMography Nano crYo) instrument, is operating at ultra-high vacuum and offering cryogenic sample temperatures down to 10 K. In this manuscript, we present the sample mounts that were developed for these instruments. Aside from excellent mechanical stability and thermal conductivity, they also offer highly reproducible mounting. Various types were developed for different kinds of samples and are presented in detail, including examples of how specimens can be mounted on these holders. We also show the first hard x-ray ptychographic tomography measurements of high-pressure frozen biological samples, in the present case Chlamydomonas cells, the related sample pins and preparation steps. For completeness, we present accessories such as transportation containers for both room temperature and cryogenic samples and a gripper mechanism for automatic sample changing. The sample mounts are not limited to x-ray tomography or hard x-ray energies, and we believe that they can be very useful for other instrumentation projects.

  13. Nano-indentation creep properties of the S2 cell wall lamina and compound corner middle lamella [abstract

    Treesearch

    Joseph E. Jakes; Charles R. Frihart; James F. Beecher; Donald S. Stone

    2010-01-01

    Bulk wood properties are derived from an ensemble of processes taking place at the micron-scale, and at this level the properties differ dramatically in going from cell wall layers to the middle lamella. To better understand the properties of these micron-scaled regions of wood, we have developed a unique set of nano-indentation tools that allow us to measure local...

  14. 16 CFR 1615.4 - Test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) Specimen holder. The specimen holder is designed to permit suspension of the specimen in a fixed vertical... series of loads for char length determinations. Suitable metal hooks consist of No. 19 gauge steel wire... least 8 h at 21±1.1 °C (70±2 °F) and 65±2 pct relative humidity. Shorter conditioning times may be used...

  15. Fabrication of Metallic Biomedical Scaffolds with the Space Holder Method: A Review

    PubMed Central

    Arifvianto, Budi; Zhou, Jie

    2014-01-01

    Bone tissue engineering has been increasingly studied as an alternative approach to bone defect reconstruction. In this approach, new bone cells are stimulated to grow and heal the defect with the aid of a scaffold that serves as a medium for bone cell formation and growth. Scaffolds made of metallic materials have preferably been chosen for bone tissue engineering applications where load-bearing capacities are required, considering the superior mechanical properties possessed by this type of materials to those of polymeric and ceramic materials. The space holder method has been recognized as one of the viable methods for the fabrication of metallic biomedical scaffolds. In this method, temporary powder particles, namely space holder, are devised as a pore former for scaffolds. In general, the whole scaffold fabrication process with the space holder method can be divided into four main steps: (i) mixing of metal matrix powder and space-holding particles; (ii) compaction of granular materials; (iii) removal of space-holding particles; (iv) sintering of porous scaffold preform. In this review, detailed procedures in each of these steps are presented. Technical challenges encountered during scaffold fabrication with this specific method are addressed. In conclusion, strategies are yet to be developed to address problematic issues raised, such as powder segregation, pore inhomogeneity, distortion of pore sizes and shape, uncontrolled shrinkage and contamination. PMID:28788638

  16. Thermomagnetic processing of liquid-crystalline epoxy resins and their mechanical characterization using nanoindentation.

    PubMed

    Li, Yuzhan; Rios, Orlando; Kessler, Michael R

    2014-11-12

    A thermomagnetic processing method was used to produce a biphenyl-based liquid-crystalline epoxy resin (LCER) with oriented liquid-crystalline (LC) domains. The orientation of the LCER was confirmed and quantified using two-dimensional X-ray diffraction. The effect of molecular alignment on the mechanical and thermomechanical properties of the LCER was investigated using nanoindentation and thermomechanical analysis, respectively. The effect of the orientation on the fracture behavior was also examined. The results showed that macroscopic orientation of the LC domains was achieved, resulting in an epoxy network with an anisotropic modulus, hardness, creep behavior, and thermal expansion.

  17. The nano-epsilon dot method for strain rate viscoelastic characterisation of soft biomaterials by spherical nano-indentation.

    PubMed

    Mattei, G; Gruca, G; Rijnveld, N; Ahluwalia, A

    2015-10-01

    Nano-indentation is widely used for probing the micromechanical properties of materials. Based on the indentation of surfaces using probes with a well-defined geometry, the elastic and viscoelastic constants of materials can be determined by relating indenter geometry and measured load and displacement to parameters which represent stress and deformation. Here we describe a method to derive the viscoelastic properties of soft hydrated materials at the micro-scale using constant strain rates and stress-free initial conditions. Using a new self-consistent definition of indentation stress and strain and corresponding unique depth-independent expression for indentation strain rate, the epsilon dot method, which is suitable for bulk compression testing, is transformed to nano-indentation. We demonstrate how two materials can be tested with a displacement controlled commercial nano-indentor using the nano-espilon dot method (nano-ε̇M) to give values of instantaneous and equilibrium elastic moduli and time constants with high precision. As samples are tested in stress-free initial conditions, the nano-ε̇M could be useful for characterising the micro-mechanical behaviour of soft materials such as hydrogels and biological tissues at cell length scales. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Nanoindentation of the pristine and irradiated forms of a sodium borosilicate glass: Insights from molecular dynamics simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kilymis, D. A.; Ispas, S., E-mail: simona.ispas-crouzet@umontpellier.fr; Delaye, J.-M.

    2016-07-28

    We have carried out classical molecular dynamics simulations in order to get insight into the atomistic mechanisms of the deformation during nanoindentation of the pristine and irradiated forms of a sodium borosilicate glass. In terms of the glass hardness, we have found that the primary factor affecting the decrease of hardness after irradiation is depolymerization rather than free volume, and we argue that this is a general trend applicable to other borosilicate glasses with similar compositions. We have analyzed the changes of the short- and medium-range structures under deformation and found that the creation of oxygen triclusters is an importantmore » mechanism in order to describe the deformation of highly polymerized borosilicate glasses and is essential in the understanding of the folding of large rings under stress. We have equally found that the less polymerized glasses present a higher amount of relative densification, while the analysis of bond-breaking during the nanoindentation has showed that shear flow is more likely to appear around sodium atoms. The results provided in this study can be proven to be useful in the interpretation of experimental results.« less

  19. Design and burn-up analyses of new type holder for silicon neutron transmutation doping.

    PubMed

    Komeda, Masao; Arai, Masaji; Tamai, Kazuo; Kawasaki, Kozo

    2016-07-01

    We have developed a new silicon irradiation holder with a neutron filter to increase the irradiation efficiency. The neutron filter is made of an alloy of aluminum and B4C particles. We fabricated a new holder based on the results of design analyses. This filter has limited use in applications requiring prolonged use due to a decrease in the amount of (10)B in B4C particles. We investigated the influence of (10)B reduction on doping distribution in a silicon ingot by using the Monte Carlo Code MVP. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Gritty Surface Sample Holder Invented To Obtain Correct X-ray Absorption Fine Structure Spectra for Concentrated Materials by Fluorescence Yield.

    PubMed

    Abe, Hitoshi; Niwa, Yasuhiro; Kimura, Masao; Murakami, Youichi; Yokoyama, Toshiharu; Hosono, Hideo

    2016-04-05

    A gritty surface sample holder has been invented to obtain correct XAFS spectra for concentrated samples by fluorescence yield (FY). Materials are usually mixed with boron nitride (BN) to prepare proper concentrations to measure XAFS spectra. Some materials, however, could not be mixed with BN and would be measured in too concentrated conditions to obtain correct XAFS spectra. Consequently, XAFS spectra will be incorrect typically with decreased intensities of the peaks. We have invented the gritty surface sample holders to obtain correct XAFS spectra even for concentrated materials for FY measurements. Pure Cu and CuO powders were measured mounted on the sample holders, and the same spectra were obtained as transmission spectra of properly prepared samples. This sample holder is useful to measure XAFS for any concentrated materials.

  1. Impact of specimen adequacy on the assessment of renal allograft biopsy specimens.

    PubMed

    Cimen, S; Geldenhuys, L; Guler, S; Imamoglu, A; Molinari, M

    2016-01-01

    The Banff classification was introduced to achieve uniformity in the assessment of renal allograft biopsies. The primary aim of this study was to evaluate the impact of specimen adequacy on the Banff classification. All renal allograft biopsies obtained between July 2010 and June 2012 for suspicion of acute rejection were included. Pre-biopsy clinical data on suspected diagnosis and time from renal transplantation were provided to a nephropathologist who was blinded to the original pathological report. Second pathological readings were compared with the original to assess agreement stratified by specimen adequacy. Cohen's kappa test and Fisher's exact test were used for statistical analyses. Forty-nine specimens were reviewed. Among these specimens, 81.6% were classified as adequate, 6.12% as minimal, and 12.24% as unsatisfactory. The agreement analysis among the first and second readings revealed a kappa value of 0.97. Full agreement between readings was found in 75% of the adequate specimens, 66.7 and 50% for minimal and unsatisfactory specimens, respectively. There was no agreement between readings in 5% of the adequate specimens and 16.7% of the unsatisfactory specimens. For the entire sample full agreement was found in 71.4%, partial agreement in 20.4% and no agreement in 8.2% of the specimens. Statistical analysis using Fisher's exact test yielded a P value above 0.25 showing that - probably due to small sample size - the results were not statistically significant. Specimen adequacy may be a determinant of a diagnostic agreement in renal allograft specimen assessment. While additional studies including larger case numbers are required to further delineate the impact of specimen adequacy on the reliability of histopathological assessments, specimen quality must be considered during clinical decision making while dealing with biopsy reports based on minimal or unsatisfactory specimens.

  2. 7 CFR 1463.105 - Base quota levels for eligible quota holders.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Base quota levels for eligible quota holders. 1463.105 Section 1463.105 Agriculture Regulations of the Department of Agriculture (Continued) COMMODITY CREDIT CORPORATION, DEPARTMENT OF AGRICULTURE LOANS, PURCHASES, AND OTHER OPERATIONS 2005-2014 TOBACCO...

  3. Mechanical Properties of Stable Glasses Using Nanoindentation

    NASA Astrophysics Data System (ADS)

    Wolf, Sarah; Liu, Tianyi; Jiang, Yijie; Ablajan, Keyume; Zhang, Yue; Walsh, Patrick; Turner, Kevin; Fakhraai, Zahra

    Glasses with enhanced stability over ordinary, liquid quenched glasses have been formed via the process of Physical Vapor Deposition (PVD) by using a sufficiently slow deposition rate and a substrate temperature slightly below the glass transition temperature. These stable glasses have been shown to exhibit higher density, lower enthalpy, and better kinetic stability over ordinary glass, and are typically optically birefringent, due to packing and orientational anisotropy. Given these exceptional properties, it is of interest to further investigate how the properties of stable glasses compare to those of ordinary glass. In particular, the mechanical properties of stable glasses remain relatively under-investigated. While the speed of sound and elastic moduli have been shown to increase with increased stability, little is known about their hardness and fracture toughness compared to ordinary glasses. In this study, glasses of 9-(3,5-di(naphthalen-1-yl)phenyl)anthracene were deposited at varying temperatures relative to their glass transition temperature, and their mechanical properties measured by nanoindentation. Hardness and elastic modulus of the glasses were compared across substrate temperatures. After indentation, the topography of these films were studied using Atomic Force Microscopy (AFM) in order to further compare the relationship between thermodynamic and kinetic stability and mechanical failure. Z.F. and P.W. acknowledge funding from NSF(DMREF-1628407).

  4. Cinemicrographic specimen housing

    NASA Technical Reports Server (NTRS)

    Wilkins, J. R.

    1979-01-01

    Housing used to observe gravitation effects on specimens embedded in support media, such as agar, supports microbial specimens vertically for time-lapsed cinemicrographic studies. Procedure cannot be performed with conventional microscopes which see specimens in horizontal plane only.

  5. 49 CFR 192.177 - Additional provisions for bottle-type holders.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... in accordance with § 192.327. (b) Each bottle-type holder manufactured from steel that is not... steel must meet the chemical and tensile requirements for the various grades of steel in ASTM A 372/A 372M. (2) The actual yield-tensile ratio of the steel may not exceed 0.85. (3) Welding may not be...

  6. 49 CFR 192.177 - Additional provisions for bottle-type holders.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... in accordance with § 192.327. (b) Each bottle-type holder manufactured from steel that is not... steel must meet the chemical and tensile requirements for the various grades of steel in ASTM A 372/A 372M. (2) The actual yield-tensile ratio of the steel may not exceed 0.85. (3) Welding may not be...

  7. Phase transformation dependence on initial plastic deformation mode in Si via nanoindentation

    DOE PAGES

    Wong, Sherman; Haberl, Bianca; Williams, James S.; ...

    2016-09-30

    Silicon in its diamond-cubic phase is known to phase transform to a technologically interesting mixture of the body-centred cubic and rhombohedral phases under nanoindentation pressure. In this study, we demonstrate that during plastic deformation the sample can traverse two distinct pathways, one that initially nucleates a phase transformation while the other initially nucleates crystalline defects. These two pathways remain distinct even after sufficient pressure is applied such that both deformation mechanisms are present within the sample. Here, it is further shown that the indents that initially nucleate a phase transformation generate larger, more uniform volumes of the phase transformed materialmore » than indents that initially nucleate crystalline defects.« less

  8. 17 CFR 240.14c-3 - Annual report to be furnished security holders.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) A registrant will be considered to have delivered a Notice of Internet Availability of Proxy... Notice of Internet Availability of Proxy Materials, annual report to security holders or information...

  9. 26 CFR 1.1272-3 - Election by a holder to treat all interest on a debt instrument as OID.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., OID, de minimis OID, market discount, de minimis market discount, and unstated interest, as adjusted... the rules provided by this section. (ii) Debt instrument with market discount. (A) A holder may make the election under this section for a debt instrument with market discount only if the holder is...

  10. 26 CFR 1.1272-3 - Election by a holder to treat all interest on a debt instrument as OID.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., OID, de minimis OID, market discount, de minimis market discount, and unstated interest, as adjusted... the rules provided by this section. (ii) Debt instrument with market discount. (A) A holder may make the election under this section for a debt instrument with market discount only if the holder is...

  11. 26 CFR 1.1272-3 - Election by a holder to treat all interest on a debt instrument as OID.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., OID, de minimis OID, market discount, de minimis market discount, and unstated interest, as adjusted... the rules provided by this section. (ii) Debt instrument with market discount. (A) A holder may make the election under this section for a debt instrument with market discount only if the holder is...

  12. Ion-irradiation-induced damage of steels characterized by means of nanoindentation

    NASA Astrophysics Data System (ADS)

    Heintze, C.; Recknagel, C.; Bergner, F.; Hernández-Mayoral, M.; Kolitsch, A.

    2009-05-01

    Self-ion irradiation was used to simulate the damage caused by fast neutrons in the austenitic stainless steel SS 304 SA, the ferritic/martensitic steel Eurofer'97 and a Fe-9 at.%Cr model alloy. The irradiation-induced hardness change in the damage layer was evaluated by means of nanoindentation. Three-step irradiations were performed at room temperature and 300 °C up to 1 and 10 dpa. An irradiation-induced hardness change was shown for all materials. No influence of irradiation temperature could be resolved. Irradiation-induced hardening exhibits different fluence dependencies in Eurofer'97 and Fe-9 at.%Cr. While the data indicate a saturation-like behaviour for Fe-9 at.%Cr, an increase of hardness with fluence up to 10 dpa was found for Eurofer'97.

  13. 26 CFR 1.1272-3 - Election by a holder to treat all interest on a debt instrument as OID.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., market discount, de minimis market discount, and unstated interest, as adjusted by any amortizable bond... provided by this section. (ii) Debt instrument with market discount. (A) A holder may make the election under this section for a debt instrument with market discount only if the holder is eligible to make an...

  14. Precision tool holder with flexure-adjustable, three degrees of freedom for a four-axis lathe

    DOEpatents

    Bono, Matthew J [Pleasanton, CA; Hibbard, Robin L [Livermore, CA

    2008-03-04

    A precision tool holder for precisely positioning a single point cutting tool on 4-axis lathe, such that the center of the radius of the tool nose is aligned with the B-axis of the machine tool, so as to facilitate the machining of precision meso-scale components with complex three-dimensional shapes with sub-.mu.m accuracy on a four-axis lathe. The device is designed to fit on a commercial diamond turning machine and can adjust the cutting tool position in three orthogonal directions with sub-micrometer resolution. In particular, the tool holder adjusts the tool position using three flexure-based mechanisms, with two flexure mechanisms adjusting the lateral position of the tool to align the tool with the B-axis, and a third flexure mechanism adjusting the height of the tool. Preferably, the flexures are driven by manual micrometer adjusters. In this manner, this tool holder simplifies the process of setting a tool with sub-.mu.m accuracy, to substantially reduce the time required to set the tool.

  15. An MR/MRI compatible core holder with the RF probe immersed in the confining fluid

    NASA Astrophysics Data System (ADS)

    Shakerian, M.; Balcom, B. J.

    2018-01-01

    An open frame RF probe for high pressure and high temperature MR/MRI measurements was designed, fabricated, and tested. The open frame RF probe was installed inside an MR/MRI compatible metallic core holder, withstanding a maximum pressure and temperature of 5000 psi and 80 °C. The open frame RF probe was tunable for both 1H and 19F resonance frequencies with a 0.2 T static magnetic field. The open frame structure was based on simple pillars of PEEK polymer upon which the RF probe was wound. The RF probe was immersed in the high pressure confining fluid during operation. The open frame structure simplified fabrication of the RF probe and significantly reduced the amount of polymeric materials in the core holder. This minimized the MR background signal detected. Phase encoding MRI methods were employed to map the spin density of a sulfur hexafluoride gas saturating a Berea core plug in the core holder. The SF6 was imaged as a high pressure gas and as a supercritical fluid.

  16. An MR/MRI compatible core holder with the RF probe immersed in the confining fluid.

    PubMed

    Shakerian, M; Balcom, B J

    2018-01-01

    An open frame RF probe for high pressure and high temperature MR/MRI measurements was designed, fabricated, and tested. The open frame RF probe was installed inside an MR/MRI compatible metallic core holder, withstanding a maximum pressure and temperature of 5000 psi and 80 °C. The open frame RF probe was tunable for both 1 H and 19 F resonance frequencies with a 0.2 T static magnetic field. The open frame structure was based on simple pillars of PEEK polymer upon which the RF probe was wound. The RF probe was immersed in the high pressure confining fluid during operation. The open frame structure simplified fabrication of the RF probe and significantly reduced the amount of polymeric materials in the core holder. This minimized the MR background signal detected. Phase encoding MRI methods were employed to map the spin density of a sulfur hexafluoride gas saturating a Berea core plug in the core holder. The SF 6 was imaged as a high pressure gas and as a supercritical fluid. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Inactivation of high-risk human papillomaviruses by Holder pasteurization: implications for donor human milk banking.

    PubMed

    Donalisio, Manuela; Cagno, Valeria; Vallino, Marta; Moro, Guido E; Arslanoglu, Sertac; Tonetto, Paola; Bertino, Enrico; Lembo, David

    2014-01-01

    Several studies have recently reported the detection of oncogenic human papillomaviruses (HPV) in human milk of a minority of lactating mothers. These findings raised safety concerns in the context of human donor milk banking given the potential risk of HPV transmission to recipient infants. The aim of this study was to investigate whether the Holder pasteurization, a procedure currently in use in human donor milk banks for milk pasteurization, completely inactivates high-risk and low-risk HPV. HPV pseudoviruses (PsV) were generated, spiked into cell culture medium or donor human milk and subjected to thermal inactivation. HPV PsV infectivity and morphological integrity was analyzed by cell-based assay and by electron microscopy, respectively. The Holder pasteurization completely inactivated the infectivity of high-risk (types 16 and 18) and low-risk (type 6) HPV both in cell culture medium and in human milk causing PsV particle disassembly. The results presented here indicate that the Holder pasteurization is an efficient procedure to inactivate high-risk and low-risk HPV thus preventing the potential risk of their transmission through human donor milk.

  18. [Measurement of external pressure of peroneal nerve tract coming in contact with lithotomy leg holders using pressure distribution measurement system BIG-MAT®].

    PubMed

    Mizuno, Ju; Namba, Chikara; Takahashi, Toru

    2014-10-01

    We investigated external pressure on peroneal nerve tract coming in contact with two kinds of leg holders using pressure distribution measurement system BIG- MAT® (Nitta Corp., Osaka) in the lithotomy position Peak contact (active) pressure at the left fibular head region coming in contact with knee-crutch-type leg holder M® (Takara Belmont Corp., Osaka), which supports the left popliteal fossa, was 78.0 ± 26.4 mmHg. On the other hand, peak contact pressure at the left lateral lower leg region coming in contact with boot-support-type leg holder Bel Flex® (Takara Belmont Corp., Osaka), which supports the left lower leg and foot was 26.3±7.9 mmHg. These results suggest that use of knee-crutch-type leg holder is more likely to induce common peroneal nerve palsy at the fibular head region, but use of boot-support-type leg holder dose not easily induce superficial peroneal nerve palsy at the lateral lower leg region, because capillary blood pressure is known to be 32 mmHg. Safer holders for positioning will be developed to prevent nerve palsy based on the analysis of chronological change in external pressure using BIG-MAT® system during anesthesia.

  19. Temperature-dependent mechanical properties of single-layer molybdenum disulphide: Molecular dynamics nanoindentation simulations

    NASA Astrophysics Data System (ADS)

    Zhao, Junhua; Jiang, Jin-Wu; Rabczuk, Timon

    2013-12-01

    The temperature-dependent mechanical properties of single-layer molybdenum disulphide (MoS2) are obtained using molecular dynamics (MD) nanoindentation simulations. The Young's moduli, maximum load stress, and maximum loading strain decrease with increasing temperature from 4.2 K to 500 K. The obtained Young's moduli are in good agreement with those using our MD uniaxial tension simulations and the available experimental results. The tendency of maximum loading strain with different temperature is opposite with that of metal materials due to the short range Stillinger-Weber potentials in MoS2. Furthermore, the indenter tip radius and fitting strain effect on the mechanical properties are also discussed.

  20. Note: A sample holder design for sensitive magnetic measurements at high temperatures in a magnetic properties measurement system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arauzo, A.; Guerrero, E.; Urtizberea, A.

    2012-06-15

    A sample holder design for high temperature measurements in a commercial MPMS SQUID magnetometer from Quantum Design is presented. It fulfills the requirements for the simultaneous use of the oven and reciprocating sample option (RSO) options, thus allowing sensitive magnetic measurements up to 800 K. Alternating current susceptibility can also be measured, since the holder does not induce any phase shift relative to the ac driven field. It is easily fabricated by twisting Constantan Copyright-Sign wires into a braid nesting the sample inside. This design ensures that the sample be placed tightly into a tough holder with its orientation fixed,more » and prevents any sample displacement during the fast movements of the RSO transport, up to high temperatures.« less

  1. 76 FR 42130 - Agency Information Collection Activities: BioWatch Filter Holder Log

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-18

    ... DEPARTMENT OF HOMELAND SECURITY Agency Information Collection Activities: BioWatch Filter Holder...) assigned responsibility for installing and removing filters from aerosol collection devices and transportation to local laboratories for sample analysis. A standard filter log form is completed for each sample...

  2. 76 FR 24504 - Agency Information Collection Activities: BioWatch Filter Holder Log

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-02

    ... DEPARTMENT OF HOMELAND SECURITY Agency Information Collection Activities: BioWatch Filter Holder...) assigned responsibility for installing and removing filters from aerosol collection devices and transportation to local laboratories for sample analysis. A standard filter log form is completed for each sample...

  3. Electron back-scattered diffraction and nanoindentation analysis of nanostructured Al tubes processed by multipass tubular-channel angular pressing

    NASA Astrophysics Data System (ADS)

    Mesbah, Mohsen; Faraji, Ghader; Bushroa, A. R.

    2016-03-01

    Microstructural evolution and mechanical properties of nanostructured 1060 aluminum alloy tubes processed by tubular-channel angular pressing (TCAP) process were investigated using electron back-scattered diffraction (EBSD), transmission electron microscopy (TEM) and nanoindentation analyzes. EBSD scans revealed a homogeneous ultrafine grained microstructure after the third passes of the TCAP process. Apart from that the mean grain sizes of the TCAP processed tubes were refined to 566 nm, 500 nm and 480 nm respectively after the first, second and third passes. The results showed that after the three TCAP passes, the grain boundaries with a high angle comprised 78% of all the boundaries. This is in comparison to the first pass processed sample that includes approximately 20% HAGBs. The TEM inspection afforded an appreciation of the role of very low-angle misorientation boundaries in the process of refining microstructure. Nanoindentation results showed that hardness was the smallest form of an unprocessed sample while the largest form of the processed sample after the three passes of TCAP indicated the highest resistant of the material. In addition, the module of elasticity of the TCAP processed samples was greater from that of the unprocessed sample.

  4. 19 CFR 134.23 - Containers or holders designed for or capable of reuse.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... containers or holders are subject to the treatment specified in General Rule of Interpretation 5(b... cologne bottles reusable as flower vases, and other containers which have a lasting value or decorative...

  5. 19 CFR 134.23 - Containers or holders designed for or capable of reuse.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... containers or holders are subject to the treatment specified in General Rule of Interpretation 5(b... cologne bottles reusable as flower vases, and other containers which have a lasting value or decorative...

  6. 19 CFR 134.23 - Containers or holders designed for or capable of reuse.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... containers or holders are subject to the treatment specified in General Rule of Interpretation 5(b... cologne bottles reusable as flower vases, and other containers which have a lasting value or decorative...

  7. 19 CFR 134.23 - Containers or holders designed for or capable of reuse.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... containers or holders are subject to the treatment specified in General Rule of Interpretation 5(b... cologne bottles reusable as flower vases, and other containers which have a lasting value or decorative...

  8. 17 CFR 270.32a-2 - Exemption for initial period from vote of security holders on independent public accountant for...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... from vote of security holders on independent public accountant for certain registered separate accounts... from vote of security holders on independent public accountant for certain registered separate accounts... 32(a) of the Act that selection of an independent public accountant shall have been submitted for...

  9. 17 CFR 270.32a-2 - Exemption for initial period from vote of security holders on independent public accountant for...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... from vote of security holders on independent public accountant for certain registered separate accounts... from vote of security holders on independent public accountant for certain registered separate accounts... 32(a) of the Act that selection of an independent public accountant shall have been submitted for...

  10. 17 CFR 270.32a-2 - Exemption for initial period from vote of security holders on independent public accountant for...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... from vote of security holders on independent public accountant for certain registered separate accounts... from vote of security holders on independent public accountant for certain registered separate accounts... 32(a) of the Act that selection of an independent public accountant shall have been submitted for...

  11. 17 CFR 270.32a-2 - Exemption for initial period from vote of security holders on independent public accountant for...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... from vote of security holders on independent public accountant for certain registered separate accounts... from vote of security holders on independent public accountant for certain registered separate accounts... 32(a) of the Act that selection of an independent public accountant shall have been submitted for...

  12. 17 CFR 270.32a-2 - Exemption for initial period from vote of security holders on independent public accountant for...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... from vote of security holders on independent public accountant for certain registered separate accounts... from vote of security holders on independent public accountant for certain registered separate accounts... 32(a) of the Act that selection of an independent public accountant shall have been submitted for...

  13. Spring loaded thermocouple module

    DOEpatents

    McKelvey, T.E.; Guarnieri, J.J.

    1984-03-13

    A thermocouple arrangement is provided for mounting in a blind hole of a specimen. The thermocouple arrangement includes a cup-like holder member, which receives an elongated thermal insulator, one end of which is seated at an end wall of the holder. A pair of thermocouple wires, threaded through passageways in the insulator, extend beyond the insulator member, terminating in free ends which are joined together in a spherical weld bead. A spring, held captive within the holder, applies a bias force to the weld bead, through the insulator member. The outside surface of the holder is threaded for engagement with the blind hole of the specimen. When the thermocouple is installed in the specimen, the spherical contact surface of the weld bead is held in contact with the end wall of the blind hole, with a predetermined bias force.

  14. Spring loaded thermocouple module

    DOEpatents

    McKelvey, Thomas E.; Guarnieri, Joseph J.

    1985-01-01

    A thermocouple arrangement is provided for mounting in a blind hole of a specimen. The thermocouple arrangement includes a cup-like holder member, which receives an elongated thermal insulator, one end of which is seated at an end wall of the holder. A pair of thermocouple wires, threaded through passageways in the insulator, extend beyond the insulator member, terminating in free ends which are joined together in a spherical weld bead. A spring, held captive within the holder, applies a bias force to the weld bead, through the insulator member. The outside surface of the holder is threaded for engagement with the blind hole of the specimen. When the thermocouple is installed in the specimen, the spherical contact surface of the weld bead is held in contact with the end wall of the blind hole, with a predetermined bias force.

  15. Investigation of Interface Bonding Mechanism of an Explosively Welded Tri-Metal Titanium/Aluminum/Magnesium Plate by Nanoindentation

    NASA Astrophysics Data System (ADS)

    Zhang, T. T.; Wang, W. X.; Zhou, J.; Cao, X. Q.; Yan, Z. F.; Wei, Y.; Zhang, W.

    2018-04-01

    A tri-metal titanium/aluminum/magnesium (Ti/Al/Mg) cladding plate, with an aluminum alloy interlayer plate, was fabricated for the first time by explosive welding. Nanoindentation tests and associated microstructure analysis were conducted to investigate the interface bonding mechanisms of the Ti/Al/Mg cladding plate. A periodic wavy bonding interface (with an amplitude of approximately 30 μm and a wavelength of approximately 160 μm) without a molten zone was formed between the Ti and Al plates. The bonding interface between the Al and the Mg demonstrated a similar wavy shape, but the wave at this location was much larger with an amplitude of approximately 390 μm and a wavelength of approximately 1580 μm, and some localized melted zones also existed at this location. The formation of the wavy interface was found to result from a severe deformation at the interface, which was caused by the strong impact or collision. The nanoindentation tests showed that the material hardness decreased with increasing distance from the bonding interface. Material hardness at a location was found to be correlated with the degree of plastic deformation at that site. A larger plastic deformation was correlated with an increase in hardness.

  16. Influence and evolution mechanism of different sharpness contact forms to mechanical property of cortical bone by nanoindentation

    NASA Astrophysics Data System (ADS)

    Sun, Xingdong; Guo, Yue; Li, Lijia; Liu, Zeyang; Wu, Di; Shi, Dong; Zhao, Hongwei; Zhang, Shizhong

    2018-03-01

    Based on different damage forms of various contact forms to bone, the mechanical response and mechanism were investigated by nanoindentation under different sharpness contact forms. For the purpose of simulating the different sharpness contact forms, two kinds of indenters were used in experiments and finite elements simulations. Through nanoindentation experiments, it was concluded that the residual depth of sharp indenter was bigger than that of blunt indenter with small penetration depth. However, the contrary law was obtained with bigger penetration depth. There was a turning point of transition from blunt tendency to sharp tendency. By calculation, it was concluded that the sharper the indenter was, the bigger the proportion of plastic energy in total energy was. Basically, results of finite elements simulation could correspond with the experimental conclusions. By the observation of FE-SEM, the surface of cortical bone compressed was more seriously directly below the blunt indenter than the lateral face. For the berkovich indenter, the surface of indentation compressed was less directly below the indenter, but seriously on three lateral faces. This research may provide some new references to the studies of bone fracture mechanism in different load patterns in the initial press-in stage and offer new explanation for bone trauma diagnosis in clinical treatment and criminal investigation.

  17. Nanomechanical properties of dental resin-composites.

    PubMed

    El-Safty, S; Akhtar, R; Silikas, N; Watts, D C

    2012-12-01

    To determine by nanoindentation the hardness and elastic modulus of resin-composites, including a series with systematically varied filler loading, plus other representative materials that fall into the categories of flowable, bulk-fill and conventional nano-hybrid types. Ten dental resin-composites: three flowable, three bulk-fill and four conventional were investigated using nanoindentation. Disc specimens (15mm×2mm) were prepared from each material using a metallic mold. Specimens were irradiated in the mold at top and bottom surfaces in multiple overlapping points (40s each) with light curing unit at 650mW/cm(2). Specimens were then mounted in 3cm diameter phenolic ring forms and embedded in a self-curing polystyrene resin. After grinding and polishing, specimens were stored in distilled water at 37°C for 7 days. Specimens were investigated using an Agilent Technologies XP nanoindenter equipped with a Berkovich diamond tip (100nm radius). Each specimen was loaded at one loading rate and three different unloading rates (at room temperature) with thirty indentations, per unloading rate. The maximum load applied by the nanoindenter to examine the specimens was 10mN. Dependent on the type of the resin-composite material, the mean values ranged from 0.73GPa to 1.60GPa for nanohardness and from 14.44GPa to 24.07GPa for elastic modulus. There was a significant positive non-linear correlation between elastic modulus and nanohardness (r(2)=0.88). Nonlinear regression revealed a significant positive correlation (r(2)=0.62) between elastic moduli and filler loading and a non-significant correlation (r(2)=0.50) between nanohardness and filler loading of the studied materials. Varying the unloading rates showed no consistent effect on the elastic modulus and nanohardness of the studied materials. For a specific resin matrix, both elastic moduli and nanohardness correlated positively with filler loading. For the resin-composites investigated, the group-average elastic

  18. Specimen Preparation

    NASA Astrophysics Data System (ADS)

    Williams, David B.; Carter, C. Barry

    Specimen preparation is a very broad subject; there are books devoted to this topic alone. The intention here is to summarize the techniques, suggest routes that you might follow, and above all to emphasize that there are many ways to produce a TEM specimen; the one you choose will depend on the information you need, time constraints, availability of equipment, your skill, and the material. So we’ll concentrate on the ‘principles of cooking,’ but won’t try to list all the possible ‘recipes.’ One important point to bear in mind is that your technique must not affect what you see or measure, or if it does, then you must know how. Specimen preparation artifacts may be interesting but they are not usually what you want to study. Incidentally, we’ll make ‘specimens’ from the ‘sample’ we’re investigating so we’ll look at ‘TEM specimens,’ but sometimes we, and everyone else, will interchange the two words.

  19. 33 CFR 125.33 - Holders of Coast Guard Port Security Cards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Holders of Coast Guard Port... Card are such as to warrant the belief that his presence on waterfront facilities and port and harbor... as to warrant the belief that his presence on waterfront facilities, and port and harbor areas...

  20. 33 CFR 125.33 - Holders of Coast Guard Port Security Cards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Holders of Coast Guard Port... Card are such as to warrant the belief that his presence on waterfront facilities and port and harbor... as to warrant the belief that his presence on waterfront facilities, and port and harbor areas...

  1. 33 CFR 125.33 - Holders of Coast Guard Port Security Cards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Holders of Coast Guard Port... Card are such as to warrant the belief that his presence on waterfront facilities and port and harbor... as to warrant the belief that his presence on waterfront facilities, and port and harbor areas...

  2. 33 CFR 125.33 - Holders of Coast Guard Port Security Cards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Holders of Coast Guard Port... Card are such as to warrant the belief that his presence on waterfront facilities and port and harbor... as to warrant the belief that his presence on waterfront facilities, and port and harbor areas...

  3. 33 CFR 125.33 - Holders of Coast Guard Port Security Cards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Holders of Coast Guard Port... Card are such as to warrant the belief that his presence on waterfront facilities and port and harbor... as to warrant the belief that his presence on waterfront facilities, and port and harbor areas...

  4. 14 CFR 26.33 - Holders of type certificates: Fuel tank flammability.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... in the Airworthiness Limitations Section (ALS) of the ICA required by 14 CFR 25.1529 or paragraph (f... 27, 2010, holders of type certificates affected by this section must establish an ALS of the... submit it to the FAA Oversight Office for approval. The ALS must include a section that contains the...

  5. 14 CFR 26.33 - Holders of type certificates: Fuel tank flammability.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... in the Airworthiness Limitations Section (ALS) of the ICA required by 14 CFR 25.1529 or paragraph (f... 27, 2010, holders of type certificates affected by this section must establish an ALS of the... submit it to the FAA Oversight Office for approval. The ALS must include a section that contains the...

  6. 14 CFR 26.33 - Holders of type certificates: Fuel tank flammability.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... in the Airworthiness Limitations Section (ALS) of the ICA required by 14 CFR 25.1529 or paragraph (f... 27, 2010, holders of type certificates affected by this section must establish an ALS of the... submit it to the FAA Oversight Office for approval. The ALS must include a section that contains the...

  7. 14 CFR 26.33 - Holders of type certificates: Fuel tank flammability.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... in the Airworthiness Limitations Section (ALS) of the ICA required by 14 CFR 25.1529 or paragraph (f... 27, 2010, holders of type certificates affected by this section must establish an ALS of the... submit it to the FAA Oversight Office for approval. The ALS must include a section that contains the...

  8. 14 CFR 26.33 - Holders of type certificates: Fuel tank flammability.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... in the Airworthiness Limitations Section (ALS) of the ICA required by 14 CFR 25.1529 or paragraph (f... 27, 2010, holders of type certificates affected by this section must establish an ALS of the... submit it to the FAA Oversight Office for approval. The ALS must include a section that contains the...

  9. Clinical evaluation of a mobile digital specimen radiography system for intraoperative specimen verification.

    PubMed

    Wang, Yingbing; Ebuoma, Lilian; Saksena, Mansi; Liu, Bob; Specht, Michelle; Rafferty, Elizabeth

    2014-08-01

    Use of mobile digital specimen radiography systems expedites intraoperative verification of excised breast specimens. The purpose of this study was to evaluate the performance of a such a system for verifying targets. A retrospective review included 100 consecutive pairs of breast specimen radiographs. Specimens were imaged in the operating room with a mobile digital specimen radiography system and then with a conventional digital mammography system in the radiology department. Two expert reviewers independently scored each image for image quality on a 3-point scale and confidence in target visualization on a 5-point scale. A target was considered confidently verified only if both reviewers declared the target to be confidently detected. The 100 specimens contained a total of 174 targets, including 85 clips (49%), 53 calcifications (30%), 35 masses (20%), and one architectural distortion (1%). Although a significantly higher percentage of mobile digital specimen radiographs were considered poor quality by at least one reviewer (25%) compared with conventional digital mammograms (1%), 169 targets (97%), were confidently verified with mobile specimen radiography; 172 targets (98%) were verified with conventional digital mammography. Three faint masses were not confidently verified with mobile specimen radiography, and conventional digital mammography was needed for confirmation. One faint mass and one architectural distortion were not confidently verified with either method. Mobile digital specimen radiography allows high diagnostic confidence for verification of target excision in breast specimens across target types, despite lower image quality. Substituting this modality for conventional digital mammography can eliminate delays associated with specimen transport, potentially decreasing surgical duration and increasing operating room throughput.

  10. Successive measurements of streaming potential and electroosmotic pressure with the same core-holder

    NASA Astrophysics Data System (ADS)

    Yin, Chenggang; Hu, Hengshan; Yu, Chunhao; Wang, Jun

    2018-05-01

    Successive measurements of the streaming potential and electroosmotic pressure of each core sample are important for understanding the mechanisms of electrokinetic effects. In previous studies, one plug of the core-holder needs to be replaced in these two experiments, which causes the change of the fluid parameters and the boundary conditions in the core. We design a new core-holder to permit successive experiments without plug replacement, which ensures the consistency of the measurement environment. A two-direction harmonic pressure-driving source is accordingly designed. Using this new equipment, electrokinetic experiments conducted ten core samples at 0.4 mol/L NaCl solution. The results show good agreement between the electrokinetically deduced permeability and premeasured gas permeability. For high salinity saturated samples, the permeability can be inverted from electroosmotic effect instead of the streaming potential.

  11. Probing elastically or plastically induced structural heterogeneities in bulk metallic glasses by nanoindentation pop-in tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Tingkun; Gao, Yanfei; Bei, Hongbin

    Shear banding dynamics in bulk metallic glasses (BMGs) is manifested by the spatiotemporal evolution of strain fields which in turn depend on structural heterogeneities. The spacing of these heterogeneities, as a characteristic length scale, was determined from the analysis of nanoindentation pop-in tests using a stochastic model. Furthermore, the pre-stress by elastic bending and residual stress by plastic bending of BMG plates were found to dramatically decrease such spacings, thus increasing heterogeneity density and mechanically rejuvenating the glass structure.

  12. Probing elastically or plastically induced structural heterogeneities in bulk metallic glasses by nanoindentation pop-in tests

    DOE PAGES

    Liu, Tingkun; Gao, Yanfei; Bei, Hongbin

    2017-07-21

    Shear banding dynamics in bulk metallic glasses (BMGs) is manifested by the spatiotemporal evolution of strain fields which in turn depend on structural heterogeneities. The spacing of these heterogeneities, as a characteristic length scale, was determined from the analysis of nanoindentation pop-in tests using a stochastic model. Furthermore, the pre-stress by elastic bending and residual stress by plastic bending of BMG plates were found to dramatically decrease such spacings, thus increasing heterogeneity density and mechanically rejuvenating the glass structure.

  13. Nanoindentation mapping of a wood-adhesive bond

    NASA Astrophysics Data System (ADS)

    Konnerth, J.; Valla, A.; Gindl, W.

    2007-08-01

    A mapping experiment of a wood phenol-resorcinol-formaldehyde adhesive bond was performed by means of grid nanoindentation. The variability of the modulus of elasticity and the hardness was evaluated for an area of 17 μm by 90 μm. Overall, the modulus of elasticity of the adhesive was clearly lower than the modulus of wood cell walls, whereas the hardness of the adhesive was slightly higher compared to cell walls. A very slight trend of decreasing modulus of elasticity was found with increasing distance from the immediate bond line. However, the trend was superimposed by a high variability of the modulus of elasticity in dependence on the position in the wood cell wall. The unexpectedly high variation of the modulus between 12 and 24 GPa may be explained by the interaction between the helical orientation of the cellulose microfibrils in the S2 layer of the wood cell wall and the geometry of the three-sided Berkovich type indenter pyramid used. Corresponding to the very slight decrease in modulus with increasing distance from the bond line, a similar but clearer trend was found for hardness. Both trends of changing mechanical properties of wood cell walls with varying distance from the bond line are attributed to effects of adhesive penetration into the wood cell wall.

  14. Nanoindentation data analysis of loading curve performed on DLC thin films: Effect of residual stress on the elasto-plastic properties

    NASA Astrophysics Data System (ADS)

    Ouchabane, M.; Dublanche-Tixier, Ch.; Dergham, D.

    2017-11-01

    The present work is a contribution to the understanding of the mechanical behavior of DLC thin films through nanoindentation tests. DLC films of different thicknesses deposited by the PECVD process on a silicon substrate contain high residual compressive stresses when they are very thin and the stresses become relatively low and more relaxed as the film thickens. These different levels of residual stress influence the values of hardness (H) and Young's modulus (E) obtained when probing the film-substrate system by nanoindentation. It is observed that the DLC layers exhibit different mechanical behaviors even when they are deposited under the same conditions. It is proposed that the compressive stress induces structural modifications resulting in modifying the elasto-plastic properties of each thin film-substrate system. Data analysis of the loading curve can provide information on the elasto-plastic properties of DLC thin films, particularly the stiffness (S) and Er2/H, as a function of residual compressive stresses. The structural changes induced by residual stresses were probed by using Raman spectroscopy and correlated to the mechanical properties.

  15. Method of fission heat flux determination from experimental data

    DOEpatents

    Paxton, Frank A.

    1999-01-01

    A method is provided for determining the fission heat flux of a prime specimen inserted into a specimen of a test reactor. A pair of thermocouple test specimens are positioned at the same level in the holder and a determination is made of various experimental data including the temperature of the thermocouple test specimens, the temperature of bulk water channels located in the test holder, the gamma scan count ratios for the thermocouple test specimens and the prime specimen, and the thicknesses of the outer clads, the fuel fillers, and the backclad of the thermocouple test specimen. Using this experimental data, the absolute value of the fission heat flux for the thermocouple test specimens and prime specimen can be calculated.

  16. Molten metal holder furnace and casting system incorporating the molten metal holder furnace

    DOEpatents

    Kinosz, Michael J.; Meyer, Thomas N.

    2003-02-11

    A bottom heated holder furnace (12) for containing a supply of molten metal includes a storage vessel (30) having sidewalls (32) and a bottom wall (34) defining a molten metal receiving chamber (36). A furnace insulating layer (42) lines the molten metal receiving chamber (36). A thermally conductive heat exchanger block (54) is located at the bottom of the molten metal receiving chamber (36) for heating the supply of molten metal. The heat exchanger block (54) includes a bottom face (65), side faces (66), and a top face (67). The heat exchanger block (54) includes a plurality of electrical heaters (70) extending therein and projecting outward from at least one of the faces of the heat exchanger block (54), and further extending through the furnace insulating layer (42) and one of the sidewalls (32) of the storage vessel (30) for connection to a source of electrical power. A sealing layer (50) covers the bottom face (65) and side faces (66) of the heat exchanger block (54) such that the heat exchanger block (54) is substantially separated from contact with the furnace insulating layer (42).

  17. A New Micro-holder Device for Local Drug Delivery during In Vivo Whole-cell Recordings.

    PubMed

    Sáez, María; Ketzef, Maya; Alegre-Cortés, Javier; Reig, Ramón; Silberberg, Gilad

    2018-06-15

    Focal administration of pharmacological agents during in vivo recordings is a useful technique to study the functional properties of neural microcircuits. However, the lack of visual control makes this task difficult and inaccurate, especially when targeting small and deep regions where spillover to neighboring regions is likely to occur. An additional problem with recording stability arises when combining focal drug administration with in vivo intracellular recordings, which are highly sensitive to mechanical vibrations. To address these technical issues, we designed a micro-holder that enables accurate local application of pharmacological agents during in vivo whole-cell recordings. The holder couples the recording and drug delivery pipettes with adjustable distance between the respective tips adapted to the experimental needs. To test the efficacy of the micro-holder we first performed whole-cell recordings in mouse primary somatosensory cortex (S1) with simultaneous extracellular recordings in S1 and motor cortex (M1), before and after local application of bicuculline methiodide (BMI 200 µM). The blockade of synaptic inhibition resulted in increased amplitudes and rising slopes of "Up states", and shortening of their duration. We then checked the usability of the micro-holder in a deeper brain structure, the striatum. We applied tetrodotoxin (TTX 10 µM) during whole-cell recordings in the striatum, while simultaneously obtaining extracellular recordings in S1 and M1. The focal application of TTX in the striatum blocked Up states in the recorded striatal neurons, without affecting the cortical activity. We also describe two different approaches for precisely releasing the drugs without unwanted leakage along the pipette approach trajectory. Copyright © 2018 IBRO. Published by Elsevier Ltd. All rights reserved.

  18. Effect of thermo-mechanical refining pressure on the properties of wood fibers as measured by nanoindentation and atomic force microscopy

    Treesearch

    Cheng Xing; Siqun Wang; George M. Pharr; Leslie H. Groom

    2008-01-01

    Refined wood fibers of a 54-year-old loblolly pine (Pinus taeda L.) mature wood were investigated by nanoindentation and atomic force microscopy (AFM). The effect of steam pressure, in the range of 2?18 bar, during thermomechanical refining was investigated and the nanomechanical properties and nano- or micro-level damages of the cell wall were...

  19. Development of porous titanium for biomedical applications: A comparison between loose sintering and space-holder techniques.

    PubMed

    Torres, Yadir; Lascano, Sheila; Bris, Jorge; Pavón, Juan; Rodriguez, José A

    2014-04-01

    One of the most important concerns in long-term prostheses is bone resorption as a result of the stress shielding due to stiffness mismatch between bone and implant. The aim of this study was to obtain porous titanium with stiffness values similar to that exhibited by cortical bone. Porous samples of commercial pure titanium grade-4 were obtained by following both loose-sintering processing and space-holder technique with NaCl between 40 and 70% in volume fraction. Both mechanical properties and porosity morphology were assessed. Young's modulus was measured using uniaxial compression testing, as well as ultrasound methodology. Complete characterization and mechanical testing results allowed us to determine some important findings: (i) optimal parameters for both processing routes; (ii) better mechanical response was obtained by using space-holder technique; (iii) pore geometry of loose sintering samples becomes more regular with increasing sintering temperature; in the case of the space-holder technique that trend was observed for decreasing volume fraction; (iv) most reliable Young's modulus measurements were achieved by ultrasound technique. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. New tool holder design for cryogenic machining of Ti6Al4V

    NASA Astrophysics Data System (ADS)

    Bellin, Marco; Sartori, Stefano; Ghiotti, Andrea; Bruschi, Stefania

    2017-10-01

    The renewed demand of increasing the machinability of the Ti6Al4V titanium alloy to produce biomedical and aerospace parts working at high temperature has recently led to the application of low-temperature coolants instead of conventional cutting fluids to increase both the tool life and the machined surface integrity. In particular, the liquid nitrogen directed to the tool rake face has shown a great capability of reducing the temperature at the chip-tool interface, as well as the chemical interaction between the tool coating and the titanium to be machined, therefore limiting the tool crater wear, and improving, at the same time, the chip breakability. Furthermore, the nitrogen is a safe, non-harmful, non-corrosive, odorless, recyclable, non-polluting and abundant gas, characteristics that further qualify it as an environmental friendly coolant to be applied to machining processes. However, the behavior of the system composed by the tool and the tool holder, exposed to the cryogenics temperatures may represent a critical issue in order to obtain components within the required geometrical tolerances. On this basis, the paper aims at presenting the design of an innovative tool holder installed on a CNC lathe, which includes the cryogenic coolant provision system, and which is able to hinder the part possible distortions due to the liquid nitrogen adduction by stabilizing its dimensions through the use of heating cartridges and appropriate sensors to monitor the temperature evolution of the tool holder.

  1. Initial experience using a robotic-driven laparoscopic needle holder with ergonomic handle: assessment of surgeons' task performance and ergonomics.

    PubMed

    Sánchez-Margallo, Juan A; Sánchez-Margallo, Francisco M

    2017-12-01

    The objective of this study is to assess the surgeons' performance and ergonomics during the use of a robotic-driven needle holder in laparoscopic suturing tasks. Six right-handed laparoscopic surgeons with different levels of experience took part in this study. Participants performed a set of three different intracorporeal suturing tasks organized in ten trials during a period of five weeks. Surgeons used both conventional (Conv) and robotic (Rob) laparoscopic needle holders. Precision using the surgical needle, quality of the intracorporeal suturing performance, execution time and leakage pressure for the urethrovesical anastomosis, as well as the ergonomics of the surgeon's hand posture, were analyzed during the first, fifth and last trials. No statistically significant differences in precision and quality of suturing performance were obtained between both groups of instruments. Surgeons required more time using the robotic instrument than using the conventional needle holder to perform the urethrovesical anastomosis, but execution time was significantly reduced after training ([Formula: see text] 0.05). There were no differences in leakage pressure for the anastomoses carried out by both instruments. After training, novice surgeons significantly improved the ergonomics of the wrist ([Formula: see text] 0.05) and index finger (Conv: 36.381[Formula: see text], Rob: 30.389[Formula: see text]; p = 0.024) when using the robotic instrument compared to the conventional needle holder. Results have shown that, although both instruments offer similar technical performance, the robotic-driven instrument results in better ergonomics for the surgeon's hand posture compared to the use of a conventional laparoscopic needle holder in intracorporeal suturing.

  2. Nanoindentation of virus capsids in a molecular model

    NASA Astrophysics Data System (ADS)

    Cieplak, Marek; Robbins, Mark O.

    2010-01-01

    A molecular-level model is used to study the mechanical response of empty cowpea chlorotic mottle virus (CCMV) and cowpea mosaic virus (CPMV) capsids. The model is based on the native structure of the proteins that constitute the capsids and is described in terms of the Cα atoms. Nanoindentation by a large tip is modeled as compression between parallel plates. Plots of the compressive force versus plate separation for CCMV are qualitatively consistent with continuum models and experiments, showing an elastic region followed by an irreversible drop in force. The mechanical response of CPMV has not been studied, but the molecular model predicts an order of magnitude higher stiffness and a much shorter elastic region than for CCMV. These large changes result from small structural changes that increase the number of bonds by only 30% and would be difficult to capture in continuum models. Direct comparison of local deformations in continuum and molecular models of CCMV shows that the molecular model undergoes a gradual symmetry breaking rotation and accommodates more strain near the walls than the continuum model. The irreversible drop in force at small separations is associated with rupturing nearly all of the bonds between capsid proteins in the molecular model, while a buckling transition is observed in continuum models.

  3. Development of miniaturized light endoscope-holder robot for laparoscopic surgery.

    PubMed

    Long, Jean-Alexandre; Cinquin, Philippe; Troccaz, Jocelyne; Voros, Sandrine; Berkelman, Peter; Descotes, Jean-Luc; Letoublon, Christian; Rambeaud, Jean-Jacques

    2007-08-01

    We have conducted experiments with an innovatively designed robot endoscope holder for laparoscopic surgery that is small and low cost. A compact light endoscope robot (LER) that is placed on the patient's skin and can be used with the patient in the lateral or dorsal supine position was tested on cadavers and laboratory pigs in order to allow successive modifications. The current control system is based on voice recognition. The range of vision is 360 degrees with an angle of 160 degrees . Twenty-three procedures were performed. The tests made it possible to advance the prototype on a variety of aspects, including reliability, steadiness, ergonomics, and dimensions. The ease of installation of the robot, which takes only 5 minutes, and the easy handling made it possible for 21 of the 23 procedures to be performed without an assistant. The LER is a camera holder guided by the surgeon's voice that can eliminate the need for an assistant during laparoscopic surgery. The ease of installation and manufacture should make it an effective and inexpensive system for use on patients in the lateral and dorsal supine positions. Randomized clinical trials will soon validate a new version of this robot prior to marketing.

  4. Design selection of an innovative tool holder for ultrasonic vibration assisted turning (IN-UVAT) using finite element analysis simulation

    NASA Astrophysics Data System (ADS)

    Rachmat, Haris; Ibrahim, M. Rasidi; Hasan, Sulaiman bin

    2017-04-01

    On of high technology in machining is ultrasonic vibration assisted turning. The design of tool holder was a crucial step to make sure the tool holder is enough to handle all forces on turning process. Because of the direct experimental approach is expensive, the paper studied to predict feasibility of tool holder displacement and effective stress was used the computational in finite element simulation. SS201 and AISI 1045 materials were used with sharp and ramp corners flexure hinges on design. The result shows that AISI 1045 material and which has ramp corner flexure hinge was the best choice to be produced. The displacement is around 11.3 micron and effective stress is 1.71e+008 N/m2 and also the factor of safety is 3.10.

  5. Adaptable Holders for Arc-Jet Screening Candidate Thermal Protection System Repair Materials

    NASA Technical Reports Server (NTRS)

    Riccio, Joe; Milhoan, Jim D.

    2010-01-01

    Reusable holders have been devised for evaluating high-temperature, plasma-resistant re-entry materials, especially fabrics. Typical material samples tested support thermal-protection-system damage repair requiring evaluation prior to re-entry into terrestrial atmosphere. These tests allow evaluation of each material to withstand the most severe predicted re-entry conditions.

  6. Preparation and characterization of porous Mg-Zn-Ca alloy by space holder technique

    NASA Astrophysics Data System (ADS)

    Annur, D.; Lestari, Franciska P.; Erryani, A.; Sijabat, Fernando A.; G. P. Astawa, I. N.; Kartika, I.

    2018-04-01

    Magnesium had been recently researched as a future biodegradable implant material. In the recent study, porous Mg-Zn-Ca alloys were developed using space holder technique in powder metallurgy process. Carbamide (10-20%wt) was added into Mg-6Zn-1Ca (in wt%) alloy system as a space holder to create porous structure material. Sintering process was done in a tube furnace under Argon atmosphere in 610 °C for 5 hours. Porous structure of the resulted alloy was examined using Scanning Electron Microscope (SEM), while the phase formation was characterized by X-ray diffraction analysis (XRD). Further, mechanical properties of porous Mg-Zn-Ca alloy was examined through compression testing. Microstructure characterization showed higher content of Carbamide in the alloy would give different type of pores. However, compression test showed that mechanical properties of Mg-Zn-Ca alloy would decrease significantly when higher content of carbamide was added.

  7. 26 CFR 1.860C-1 - Taxation of holders of residual interests.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 9 2013-04-01 2013-04-01 false Taxation of holders of residual interests. 1.860C-1 Section 1.860C-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Real Estate Investment Trusts § 1.860C-1 Taxation...

  8. 26 CFR 1.860C-1 - Taxation of holders of residual interests.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 9 2014-04-01 2014-04-01 false Taxation of holders of residual interests. 1.860C-1 Section 1.860C-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Real Estate Investment Trusts § 1.860C-1 Taxation...

  9. 26 CFR 1.860C-1 - Taxation of holders of residual interests.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 9 2012-04-01 2012-04-01 false Taxation of holders of residual interests. 1.860C-1 Section 1.860C-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Real Estate Investment Trusts § 1.860C-1 Taxation...

  10. 26 CFR 1.860C-1 - Taxation of holders of residual interests.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 9 2011-04-01 2011-04-01 false Taxation of holders of residual interests. 1.860C-1 Section 1.860C-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Real Estate Investment Trusts § 1.860C-1 Taxation...

  11. Thermal activation in Au-based bulk metallic glass characterized by high-temperature nanoindentation

    NASA Astrophysics Data System (ADS)

    Yang, Bing; Wadsworth, Jeffrey; Nieh, Tai-Gang

    2007-02-01

    High-temperature nanoindentation experiments have been conducted on a Au49Ag5.5Pd2.3Cu26.9Si16.3 bulk metallic glass from 30to140°C, utilizing loading rates ranging from 0.1to100mN/s. Generally, the hardness decreased with increasing temperature. An inhomogeneous-to-homogeneous flow transition was clearly observed when the test temperature approached the glass transition temperature. Analyses of the pop-in pattern and hardness variation showed that the inhomogeneous-to-homogeneous transition temperature was loading-rate dependent. Using a free-volume model, the authors deduced the size of the basic flow units and the activation energy for the homogeneous flow. In addition, the strain rate dependency of the transition temperature was predicted.

  12. Nanomechanical characterization of nanostructured bainitic steel: Peak Force Microscopy and Nanoindentation with AFM.

    PubMed

    Morales-Rivas, Lucia; González-Orive, Alejandro; Garcia-Mateo, Carlos; Hernández-Creus, Alberto; Caballero, Francisca G; Vázquez, Luis

    2015-11-25

    The full understanding of the deformation mechanisms in nanostructured bainite requires the local characterization of its mechanical properties, which are expected to change from one phase, bainitic ferrite, to another, austenite. This study becomes a challenging process due to the bainitic nanostructured nature and high Young's modulus. In this work, we have carried out such study by means of the combination of AFM-based techniques, such as nanoindentation and Peak Force Quantitative Nanomechanical Mapping (PF-QNM) measurements. We have addressed critically the limits and advantages of these techniques and been able to measure some elastoplastic parameters of both phases. Specifically, we have analyzed by PF-QNM two nanostructured bainitic steels, with a finer and a coarser structure, and found that both phases have a similar Young's modulus.

  13. Nonlinear finite-element analysis of nanoindentation of viral capsids

    NASA Astrophysics Data System (ADS)

    Gibbons, Melissa M.; Klug, William S.

    2007-03-01

    Recent atomic force microscope (AFM) nanoindentation experiments measuring mechanical response of the protein shells of viruses have provided a quantitative description of their strength and elasticity. To better understand and interpret these measurements, and to elucidate the underlying mechanisms, this paper adopts a course-grained modeling approach within the framework of three-dimensional nonlinear continuum elasticity. Homogeneous, isotropic, elastic, thick-shell models are proposed for two capsids: the spherical cowpea chlorotic mottle virus (CCMV), and the ellipsocylindrical bacteriophage ϕ29 . As analyzed by the finite-element method, these models enable parametric characterization of the effects of AFM tip geometry, capsid dimensions, and capsid constitutive descriptions. The generally nonlinear force response of capsids to indentation is shown to be insensitive to constitutive particulars, and greatly influenced by geometric and kinematic details. Nonlinear stiffening and softening of the force response is dependent on the AFM tip dimensions and shell thickness. Fits of the models capture the roughly linear behavior observed in experimental measurements and result in estimates of Young’s moduli of ≈280-360MPa for CCMV and ≈4.5GPa for ϕ29 .

  14. 17 CFR 240.14a-7 - Obligations of registrants to provide a list of, or mail soliciting material to, security holders.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Internet Availability of Proxy Materials (as described in § 240.14a-16), furnished by the security holder... security holder shall be sent to that address, provided that if multiple copies of the Notice of Internet... 17 Commodity and Securities Exchanges 3 2013-04-01 2013-04-01 false Obligations of registrants to...

  15. 17 CFR 240.14a-7 - Obligations of registrants to provide a list of, or mail soliciting material to, security holders.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Internet Availability of Proxy Materials (as described in § 240.14a-16), furnished by the security holder... security holder shall be sent to that address, provided that if multiple copies of the Notice of Internet... 17 Commodity and Securities Exchanges 4 2014-04-01 2014-04-01 false Obligations of registrants to...

  16. 17 CFR 240.14a-7 - Obligations of registrants to provide a list of, or mail soliciting material to, security holders.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Internet Availability of Proxy Materials (as described in § 240.14a-16), furnished by the security holder... security holder shall be sent to that address, provided that if multiple copies of the Notice of Internet... 17 Commodity and Securities Exchanges 3 2011-04-01 2011-04-01 false Obligations of registrants to...

  17. 17 CFR 240.14a-7 - Obligations of registrants to provide a list of, or mail soliciting material to, security holders.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Internet Availability of Proxy Materials (as described in § 240.14a-16), furnished by the security holder... security holder shall be sent to that address, provided that if multiple copies of the Notice of Internet... 17 Commodity and Securities Exchanges 3 2012-04-01 2012-04-01 false Obligations of registrants to...

  18. Investigation of holder pressure and size effects in micro deep drawing of rectangular work pieces driven by piezoelectric actuator.

    PubMed

    Aminzahed, Iman; Mashhadi, Mahmoud Mosavi; Sereshk, Mohammad Reza Vaziri

    2017-02-01

    Micro forming is a manufacturing process to fabricate micro parts with high quality and a cost effective manner. Deep drawing could be a favorable method for production of complicated parts in macro and micro sizes. In this paper piezoelectric actuator is used as a novel approach in the field of micro manufacturing. Also, in current work, investigations are conducted with four rectangular punches and blanks with various thicknesses. Blank holder pressure effects on thickness distributions, punch force, and springback are studied. According to the results of this work, increasing of blank holder pressure in scaled deep drawing, in contrast to thickness of drawn part, leads to decrease in the punch forces and springback. Furthermore, it is shown that in micro deep drawing, the effects of holder pressure on mentioned parameters can be ignored. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Sequencing historical specimens: successful preparation of small specimens with low amounts of degraded DNA.

    PubMed

    Sproul, John S; Maddison, David R

    2017-11-01

    Despite advances that allow DNA sequencing of old museum specimens, sequencing small-bodied, historical specimens can be challenging and unreliable as many contain only small amounts of fragmented DNA. Dependable methods to sequence such specimens are especially critical if the specimens are unique. We attempt to sequence small-bodied (3-6 mm) historical specimens (including nomenclatural types) of beetles that have been housed, dried, in museums for 58-159 years, and for which few or no suitable replacement specimens exist. To better understand ideal approaches of sample preparation and produce preparation guidelines, we compared different library preparation protocols using low amounts of input DNA (1-10 ng). We also explored low-cost optimizations designed to improve library preparation efficiency and sequencing success of historical specimens with minimal DNA, such as enzymatic repair of DNA. We report successful sample preparation and sequencing for all historical specimens despite our low-input DNA approach. We provide a list of guidelines related to DNA repair, bead handling, reducing adapter dimers and library amplification. We present these guidelines to facilitate more economical use of valuable DNA and enable more consistent results in projects that aim to sequence challenging, irreplaceable historical specimens. © 2017 John Wiley & Sons Ltd.

  20. "Shelby County v. Holder": What It Means for the Voting Rights Act

    ERIC Educational Resources Information Center

    Schwinn, Steven D.

    2013-01-01

    This summer, the U.S. Supreme Court ruled in "Shelby County v. Holder" that Congress had exceeded its Fifteenth Amendment enforcement authority when it reauthorized a part of the Voting Rights Act (a coverage formula) that forced places with a history of discrimination to get federal approval before making changes to their election laws.…

  1. Reducing the nucleation barrier in magnetocaloric Heusler alloys by nanoindentation

    NASA Astrophysics Data System (ADS)

    Niemann, R.; Hahn, S.; Diestel, A.; Backen, A.; Schultz, L.; Nielsch, K.; Wagner, M. F.-X.; Fähler, S.

    2016-06-01

    Magnetocaloric materials are promising as solid state refrigerants for more efficient and environmentally friendly cooling devices. The highest effects have been observed in materials that exhibit a first-order phase transition. These transformations proceed by nucleation and growth which lead to a hysteresis. Such irreversible processes are undesired since they heat up the material and reduce the efficiency of any cooling application. In this article, we demonstrate an approach to decrease the hysteresis by locally changing the nucleation barrier. We created artificial nucleation sites and analyzed the nucleation and growth processes in their proximity. We use Ni-Mn-Ga, a shape memory alloy that exhibits a martensitic transformation. Epitaxial films serve as a model system, but their high surface-to-volume ratio also allows for a fast heat transfer which is beneficial for a magnetocaloric regenerator geometry. Nanoindentation is used to create a well-defined defect. We quantify the austenite phase fraction in its proximity as a function of temperature which allows us to determine the influence of the defect on the transformation.

  2. Atomic force microscopy based nanoindentation study of onion abaxial epidermis walls in aqueous environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xi, Xiaoning; Tittmann, Bernhard; Kim, Seong H.

    An atomic force microscopy based nanoindentation method was employed to study how the structure of cellulose microfibril packing and matrix polymers affect elastic modulus of fully hydrated primary plant cell walls. The isolated, single-layered abaxial epidermis cell wall of an onion bulb was used as a test system since the cellulose microfibril packing in this cell wall is known to vary systematically from inside to outside scales and the most abundant matrix polymer, pectin, can easily be altered through simple chemical treatments such as ethylenediaminetetraacetic acid and calcium ions. Experimental results showed that the pectin network variation has significant impactsmore » on the cell wall modulus, and not the cellulose microfibril packing.« less

  3. Temperature dependent mechanical property of PZT film: an investigation by nanoindentation.

    PubMed

    Li, Yingwei; Feng, Shangming; Wu, Wenping; Li, Faxin

    2015-01-01

    Load-depth curves of an unpoled Lead Zirconate Titanate (PZT) film composite as a function of temperature were measured by nanoindentation technique. Its reduce modulus and hardness were calculated by the typical Oliver-Pharr method. Then the true modulus and hardness of the PZT film were assessed by decoupling the influence of substrate using methods proposed by Zhou et al. and Korsunsky et al., respectively. Results show that the indentation depth and modulus increase, but the hardness decreases at elevated temperature. The increasing of indentation depth and the decreasing of hardness are thought to be caused by the decreasing of the critical stress needed to excite dislocation initiation at high temperature. The increasing of true modulus is attributed to the reducing of recoverable indentation depth induced by back-switched domains. The influence of residual stress on the indentation behavior of PZT film composite was also investigated by measuring its load-depth curves with pre-load strains.

  4. Temperature Dependent Mechanical Property of PZT Film: An Investigation by Nanoindentation

    PubMed Central

    Li, Yingwei; Feng, Shangming; Wu, Wenping; Li, Faxin

    2015-01-01

    Load-depth curves of an unpoled Lead Zirconate Titanate (PZT) film composite as a function of temperature were measured by nanoindentation technique. Its reduce modulus and hardness were calculated by the typical Oliver-Pharr method. Then the true modulus and hardness of the PZT film were assessed by decoupling the influence of substrate using methods proposed by Zhou et al. and Korsunsky et al., respectively. Results show that the indentation depth and modulus increase, but the hardness decreases at elevated temperature. The increasing of indentation depth and the decreasing of hardness are thought to be caused by the decreasing of the critical stress needed to excite dislocation initiation at high temperature. The increasing of true modulus is attributed to the reducing of recoverable indentation depth induced by back-switched domains. The influence of residual stress on the indentation behavior of PZT film composite was also investigated by measuring its load-depth curves with pre-load strains. PMID:25768957

  5. 7 CFR 762.144 - Repurchase of guaranteed portion from a secondary market holder.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 7 2014-01-01 2014-01-01 false Repurchase of guaranteed portion from a secondary market holder. 762.144 Section 762.144 Agriculture Regulations of the Department of Agriculture (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS GUARANTEED FARM LOANS § 762.144...

  6. 49 CFR Appendix C to Part 172 - Dimensional Specifications for Recommended Placard Holder

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Dimensional Specifications for Recommended Placard Holder C Appendix C to Part 172 Transportation Other Regulations Relating to Transportation PIPELINE AND... INFORMATION, TRAINING REQUIREMENTS, AND SECURITY PLANS Pt. 172, App. C Appendix C to Part 172—Dimensional...

  7. 49 CFR Appendix C to Part 172 - Dimensional Specifications for Recommended Placard Holder

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Dimensional Specifications for Recommended Placard Holder C Appendix C to Part 172 Transportation Other Regulations Relating to Transportation PIPELINE AND... INFORMATION, TRAINING REQUIREMENTS, AND SECURITY PLANS Pt. 172, App. C Appendix C to Part 172—Dimensional...

  8. The production of calibration specimens for impact testing of subsize Charpy specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alexander, D.J.; Corwin, W.R.; Owings, T.D.

    1994-09-01

    Calibration specimens have been manufactured for checking the performance of a pendulum impact testing machine that has been configured for testing subsize specimens, both half-size (5.0 {times} 5.0 {times} 25.4 mm) and third-size (3.33 {times} 3.33 {times} 25.4 mm). Specimens were fabricated from quenched-and-tempered 4340 steel heat treated to produce different microstructures that would result in either high or low absorbed energy levels on testing. A large group of both half- and third-size specimens were tested at {minus}40{degrees}C. The results of the tests were analyzed for average value and standard deviation, and these values were used to establish calibration limitsmore » for the Charpy impact machine when testing subsize specimens. These average values plus or minus two standard deviations were set as the acceptable limits for the average of five tests for calibration of the impact testing machine.« less

  9. Holder pasteurization affects S100B concentrations in human milk.

    PubMed

    Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Li Volti, Giovanni; Galvano, Fabio; Visser, Gerard H A; Gazzolo, Diego

    2018-02-01

    Donor milk (DM) represents an important nutrition source for high-risk newborns. Holder pasteurization (HoP) is the most recommended procedure for DM treatment, providing a good compromise between microbiological safety and biological quality. HoP was previously shown to affect DM cytokines, growth factors and hormones levels, whilst no data concerning the possible effects of HoP on neurobiomarkers (NB) are available. Therefore, our study investigated whether the concentration in DM of a well-known NB involved in brain development/damage, namely S100B, changes due to HoP. We conducted a pretest-test study in 11 mothers, whose DM samples were sub-divided into two parts: the first was immediately frozen (-80 °C); the second was pasteurized with Holder method before freezing. S100B DM levels were measured using a commercially available immunoluminometric assay. S100B protein was detected in all milk samples. Results showed significant differences between groups (p < 0.05) in S100B levels after HoP. Our data provide evidence that S100B is present in preterm milk as well as in term milk during maturation degree. Moreover, the results confirm the susceptibility of this neurotrophic factor to pasteurization stresses and the need to develop new storage techniques to preserve the biological quality of human milk.

  10. 31 CFR Appendix A to Part 212 - Model Notice to Account Holder

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 2 2011-07-01 2011-07-01 false Model Notice to Account Holder A Appendix A to Part 212 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... to satisfy a debt that you have not paid. In other words, if you owe money to a person or company...

  11. 31 CFR Appendix A to Part 212 - Model Notice to Account Holder

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance: Treasury 2 2014-07-01 2014-07-01 false Model Notice to Account Holder A Appendix A to Part 212 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... to satisfy a debt that you have not paid. In other words, if you owe money to a person or company...

  12. 31 CFR Appendix A to Part 212 - Model Notice to Account Holder

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 2 2012-07-01 2012-07-01 false Model Notice to Account Holder A Appendix A to Part 212 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... to satisfy a debt that you have not paid. In other words, if you owe money to a person or company...

  13. 31 CFR Appendix A to Part 212 - Model Notice to Account Holder

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 2 2013-07-01 2013-07-01 false Model Notice to Account Holder A Appendix A to Part 212 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... to satisfy a debt that you have not paid. In other words, if you owe money to a person or company...

  14. Positioning apparatus

    DOEpatents

    Vogel, Max A.; Alter, Paul

    1986-05-06

    An apparatus for precisely positioning materials test specimens within the optimum neutron flux path emerging from a neutron source located in a housing. The test specimens are retained in a holder mounted on the free end of a support pivotably mounted and suspended from a movable base plate. The support is gravity biased to urge the holder in a direction longitudinally of the flux path against the housing. Means are provided for moving the base plate in two directions to effect movement of the holder in two mutually perpendicular directions normal to the axis of the flux path.

  15. Positioning apparatus

    DOEpatents

    Vogel, Max A.; Alter, Paul

    1986-01-01

    An apparatus for precisely positioning materials test specimens within the optimum neutron flux path emerging from a neutron source located in a housing. The test specimens are retained in a holder mounted on the free end of a support pivotably mounted and suspended from a movable base plate. The support is gravity biased to urge the holder in a direction longitudinally of the flux path against the housing. Means are provided for moving the base plate in two directions to effect movement of the holder in two mutually perpendicular directions normal to the axis of the flux path.

  16. Actin cytoskeleton stiffness grades metastatic potential of ovarian carcinoma Hey A8 cells via nanoindentation mapping.

    PubMed

    Zhou, Z L; Sun, X X; Ma, J; Tong, M H; To, S K Y; Wong, A S T; Ngan, A H W

    2017-07-26

    Recent studies have indicated that the nanoindentation measured stiffness of carcinoma adherent cells is in general lower than normal cells, thus suggesting that cell stiffness may serve as a bio-marker for carcinoma. However, the proper establishment of such a conclusion would require biophysical understanding of the underlying mechanism of the cell stiffness. In this work, we compared the elastic moduli of the actin cytoskeletons of Hey A8 ovarian carcinoma cells with and without metastasis (HM and NM), as measured by 2D atomic force microscopy (AFM) with low-depth nanoindentation via a rate-jump method. The results indicate clearly that HM cells showed lower actin cytoskeleton stiffness atop of their nucleus position and higher actin cytoskeleton stiffness at their rims, compared to NM cells, suggesting that the local stiffness on the cytoskeleton can reflect actin filament distribution. Immunofluorescence staining and scanning electron microscopy (SEM) also indicated that the difference in stiffness in Hey A8 cells with different metastasis is associated with their F-actin rearrangement. Finite-element modelling (FEM) shows that a migrating cell would have its actin filaments bundled together to form stress fibers, which would exhibit lower indentation stiffness than the less aligned arrangement of filaments in a non-migrating cell. The results here indicate that the actin cytoskeleton stiffness can serve as a reliable marker for grading the metastasis of adherent carcinoma cells due to their cytoskeleton change and potentially predicting the migration direction of the cells. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Practical soil analysis by laser induced breakdown spectroscopy employing subtarget supported micro mesh as a powder sample holder

    NASA Astrophysics Data System (ADS)

    Suyanto, Hery; Lie, Tjung Jie; Kurniawan, Koo Hendrik; Kagawa, Kiichiro; Tjia, May On

    2017-11-01

    A practical alternative of sample preparation technique is proposed for direct powder analysis using laser-induced breakdown spectroscopy (LIBS) instead of the commonly adopted treatment of pelletizing the powder. The resulted pellet is known to suffer from reduced sensitivity of emission. Besides, it may also give rise to interfering effect from the binder emission. We introduce in this report a more practical technique of using a subtarget supported micro mesh (SSMM) powder sample holder. The LIBS spectrum of standard soil powder measured with 13 mJ 1064 nm Nd:YAG laser in 0.65 kPa ambient air is shown to exhibit the sharp emission lines of all the major elements in the sample. A comparison with the emission spectra measured from the pelletized powder, the spectrum obtained using the SSMM sample holder shows distinctly superior spectral quality marked by the absence of matrix effect found in pelletized powder samples, and the much stronger intensity due to the more effective shock wave plasma induced thermal excitation process produced by the hard subtarget in the sample holder. Repeating the measurement on a number of the standard soil samples of various Pb contents is shown to yield a linear calibration line with practically zero intercept and a detection limit of less than 10 ppm. We have thus demonstrated the viability of the proposed powder sample holder for the development of practical and quantitative powder analysis in the field.

  18. 13 CFR 120.651 - Claim to FTA by Registered Holder to replace Certificate.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Claim to FTA by Registered Holder to replace Certificate. 120.651 Section 120.651 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Secondary Market Miscellaneous Provisions § 120.651 Claim to FTA by Registered...

  19. Modeling of the minimum variable blank holder force based on forming limit diagram (FLD) in deep drawing process

    NASA Astrophysics Data System (ADS)

    Candra, S.; Batan, I. M. L.; Berata, W.; Pramono, A. S.

    2017-11-01

    This paper presents the mathematical approach of minimum blank holder force to prevent wrinkling in deep drawing process of the cylindrical cup. Based on the maximum of minor-major strain ratio, the slab method was applied to determine the modeling of minimum variable blank holder force (VBHF) and it compared to FE simulation. The Tin steel sheet of T4-CA grade, with the thickness of 0.2 mm was used in this study. The modeling of minimum VBHF can be used as a simple reference to prevent wrinkling in deep drawing.

  20. Comparison of linear and square superposition hardening models for the surface nanoindentation of ion-irradiated materials

    NASA Astrophysics Data System (ADS)

    Xiao, Xiazi; Yu, Long

    2018-05-01

    Linear and square superposition hardening models are compared for the surface nanoindentation of ion-irradiated materials. Hardening mechanisms of both dislocations and defects within the plasticity affected region (PAR) are considered. Four sets of experimental data for ion-irradiated materials are adopted to compare with theoretical results of the two hardening models. It is indicated that both models describe experimental data equally well when the PAR is within the irradiated layer; whereas, when the PAR is beyond the irradiated region, the square superposition hardening model performs better. Therefore, the square superposition model is recommended to characterize the hardening behavior of ion-irradiated materials.

  1. In Situ Nanoindentation Studies on Detwinning and Work Hardening in Nanotwinned Monolithic Metals

    DOE PAGES

    Liu, Y.; Li, N.; Bufford, D.; ...

    2015-07-14

    Certain nanotwinned (nt) metals have rare combinations of high mechanical strength and ductility. Here, we review recent in situ nanoindentation studies (using transmission electron microscopes) on the deformation mechanisms of nt face-centered cubic metals including Cu, Ni, and Al with a wide range of stacking fault energy (SFE). Moreover, in nt Cu with low-to-intermediate SFE, detwinning (accompanied by rapid twin boundary migration) occurs at ultralow stress. In Ni with relatively high SFE, coherent {111} twin boundaries lead to substantial work hardening. Twinned Al has abundant {112} incoherent twin boundaries, which induce significant work-hardening capability and plasticity in Al. Finally, twinmore » boundaries in Al also migrate but at very high stresses. Furthermore, molecular dynamics simulations reveal the influence of SFE on deformation mechanisms in twinned metals.« less

  2. Nanomechanical characterization of nanostructured bainitic steel: Peak Force Microscopy and Nanoindentation with AFM

    PubMed Central

    Morales-Rivas, Lucia; González-Orive, Alejandro; Garcia-Mateo, Carlos; Hernández-Creus, Alberto; Caballero, Francisca G.; Vázquez, Luis

    2015-01-01

    The full understanding of the deformation mechanisms in nanostructured bainite requires the local characterization of its mechanical properties, which are expected to change from one phase, bainitic ferrite, to another, austenite. This study becomes a challenging process due to the bainitic nanostructured nature and high Young’s modulus. In this work, we have carried out such study by means of the combination of AFM-based techniques, such as nanoindentation and Peak Force Quantitative Nanomechanical Mapping (PF-QNM) measurements. We have addressed critically the limits and advantages of these techniques and been able to measure some elastoplastic parameters of both phases. Specifically, we have analyzed by PF-QNM two nanostructured bainitic steels, with a finer and a coarser structure, and found that both phases have a similar Young’s modulus. PMID:26602631

  3. Effect of electromigration-induced back stress gradient on nanoindentation marker movement in SnAgCu solder joints

    NASA Astrophysics Data System (ADS)

    Xu, Luhua; Pang, John H. L.; Tu, K. N.

    2006-11-01

    The electromigration-induced back stress in Pb-free SnAgCu solder was studied by an area array of nanoindentation markers on the cross section of a solder joint. The marker movements driven by combined electron wind force and electromigration-induced back stress gradient were measured at different locations. The back stress gradient was determined from the observation of marker motion using the proposed model. With the applied current density of 104A/cm2 at 125°C, the stress gradient near the anode is 97kPa/μm.

  4. Fabrication and Compressive Properties of Low to Medium Porosity Closed-Cell Porous Aluminum Using PMMA Space Holder Technique

    PubMed Central

    Jamal, Nur Ayuni; Tan, Ai Wen; Yusof, Farazila; Katsuyoshi, Kondoh; Hisashi, Imai; Singh, S.; Anuar, Hazleen

    2016-01-01

    In recent years, closed-cell porous Aluminum (Al) has drawn increasing attention, particularly in the applications requiring reduced weight and energy absorption capability such as in the automotive and aerospace industries. In the present work, porous Al with closed-cell structure was successfully fabricated by powder metallurgy technique using PMMA as a space holder. The effects of the amount of PMMA powder on the porosity, density, microstructure and compressive behaviors of the porous specimens were systematically evaluated. The results showed that closed-cell porous Al having different porosities (12%–32%) and densities (1.6478 g/cm3, 1.5125 g/cm3 and 1.305 g/cm3) could be produced by varying the amount of PMMA (20–30 wt %). Meanwhile, the compressive behavior results demonstrated that the plateau stress decreased and the energy absorption capacity increased with increasing amount of PMMA. However, the maximum energy absorption capacity was achieved in the closed-cell porous Al with the addition of 25 wt % PMMA. Therefore, fabrication of closed-cell porous Al using 25 wt % PMMA is considered as the optimal condition in the present study since the resultant closed-cell porous Al possessed good combinations of porosity, density and plateau stress, as well as energy absorption capacity. PMID:28773377

  5. 12 CFR 611.1210 - Advance notices-commencement resolution and notice to equity holders.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Advance notices-commencement resolution and notice to equity holders. 611.1210 Section 611.1210 Banks and Banking FARM CREDIT ADMINISTRATION FARM..., within 10 days of adopting the commencement resolution, your bank and the other Farm Credit banks must...

  6. Effects of Holder pasteurization on the protein profile of human milk.

    PubMed

    Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Cavaletto, Maria; Spertino, Stefano; Icardi, Sara; Tortone, Claudia; Visser, Gerard H A; Gazzolo, Diego

    2016-04-07

    The most widespread method for the treatment of donor milk is the Holder pasteurization (HoP). The available literature data show that HoP may cause degradation of some bioactive components. The aim of this study was to determine the effect of HoP on the protein profile of human milk (HM) using a GeLC-MS method, a proteomic approach and a promising technique able to offer a qualitative HM protein profile. HM samples were collected by standardized methods from 20 mothers carrying both preterm and term newborns. A aliquot of each sample was immediately frozen at -80 °C, whilst another one was Holder pasteurized and then frozen. All samples were then analyzed by GeLC-MS. The protein bands of interest were excised from the gel, digested with trypsin and identified by nano-HPLC-MS/MS analysis. The protein profile before and after HoP showed qualitative differences only in 6 samples out of 20, while in the remaining 14 no detectable differences were found. The differences interested only colostrums and transitional milk samples and regarded the decrease of the electrophoretic bands corresponding to alpha and beta-casein, tenascin, lactoferrin and immunoglobulin. In the majority of samples, HoP did not cause any modification, thereby preserving the biological activity of HM proteins.

  7. Optimising probe holder design for sentinel lymph node imaging using clinical photoacoustic system with Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Sivasubramanian, Kathyayini; Periyasamy, Vijitha; Wen, Kew Kok; Pramanik, Manojit

    2017-03-01

    Photoacoustic tomography is a hybrid imaging modality that combines optical and ultrasound imaging. It is rapidly gaining attention in the field of medical imaging. The challenge is to translate it into a clinical setup. In this work, we report the development of a handheld clinical photoacoustic imaging system. A clinical ultrasound imaging system is modified to integrate photoacoustic imaging with the ultrasound imaging. Hence, light delivery has been integrated with the ultrasound probe. The angle of light delivery is optimized in this work with respect to the depth of imaging. Optimization was performed based on Monte Carlo simulation for light transport in tissues. Based on the simulation results, the probe holders were fabricated using 3D printing. Similar results were obtained experimentally using phantoms. Phantoms were developed to mimic sentinel lymph node imaging scenario. Also, in vivo sentinel lymph node imaging was done using the same system with contrast agent methylene blue up to a depth of 1.5 cm. The results validate that one can use Monte Carlo simulation as a tool to optimize the probe holder design depending on the imaging needs. This eliminates a trial and error approach generally used for designing a probe holder.

  8. Microstructural evolution and micromechanical properties of gamma-irradiated Au ball bonds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yusoff, Wan Yusmawati Wan, E-mail: yusmawati@upnm.edu.my; Ismail, Roslina, E-mail: roslina.ismail@ukm.my; Jalar, Azman, E-mail: azmn@ukm.my

    2014-07-01

    The effect of gamma radiation on the mechanical and structural properties of gold ball bonds was investigated. Gold wires from thermosonic wire bonding were exposed to gamma rays from a Cobalt-60 source at a low dose (5 Gy). The load–depth curve of nanoindentation for the irradiated gold wire bond has an apparent staircase shape during loading compared to the as-received sample. The hardness of the specimens calculated from the nanoindentation shows an increase in value from 0.91 to 1.09 GPa for specimens after exposure. The reduced elastic modulus for irradiated specimens significantly increased as well, with values from 75.18 tomore » 98.55 GPa. The change in intrinsic properties due to gamma radiation was investigated using dual-focused ion beam and high-resolution transmission electron microscope analysis. The dual-focused ion beam and high-resolution transmission electron microscope images confirmed the changes in grain structure and the presence of dislocations. The scanning electron microscope micrographs of focused ion beam cross sections showed that the grain structure of the gold became elongated and smaller after exposure to gamma rays. Meanwhile, high-resolution transmission electron microscopy provided evidence that gamma radiation induced dislocation of the atomic arrangement. - Highlights: • Nanoindentation technique provides a detailed characterisation of Au ball bond. • P–h curve of irradiated Au ball bond shows an apparent pop-in event. • Hardness and reduced modulus increased after exposure. • Elongated and smaller grain structure in irradiated specimens • Prevalent presence of dislocations in the atomic arrangement.« less

  9. Use of globally unique identifiers (GUIDs) to link herbarium specimen records to physical specimens.

    PubMed

    Nelson, Gil; Sweeney, Patrick; Gilbert, Edward

    2018-02-01

    With the advent of the U.S. National Science Foundation's Advancing Digitization of Biodiversity Collections program and related worldwide digitization initiatives, the rate of herbarium specimen digitization in the United States has expanded exponentially. As the number of electronic herbarium records proliferates, the importance of linking these records to the physical specimens they represent as well as to related records from other sources will intensify. Although a rich and diverse literature has developed over the past decade that addresses the use of specimen identifiers for facilitating linking across the internet, few implementable guidelines or recommended practices for herbaria have been advanced. Here we review this literature with the express purpose of distilling a specific set of recommendations especially tailored to herbarium specimen digitization, curation, and management. We argue that associating globally unique identifiers (GUIDs) with physical herbarium specimens and including these identifiers in all electronic records about those specimens is essential to effective digital data curation. We also address practical applications for ensuring these associations.

  10. Heavy section fracture toughness screening specimen

    NASA Technical Reports Server (NTRS)

    Shannon, J. L., Jr.; Donald, J. K.; Brown, W. F., Jr.

    1976-01-01

    Size requirements for a pin loaded double edge notch + crack tension specimen proposed for fracture toughness screening heavy section alloys were studied. Ranking of eight selected alloys based on the specimen's net strength was compared with that based on the valid plane strain fracture toughness separately determined. Performance of the specimen was judged on the basis of that comparison. The specimen's net strength was influenced by three critical specimen dimensions: distance between the crack plane and the loading hole, specimen width, and specimen thickness. Interaction between the stress fields of the crack and the loading holes reduced the net strength, but this effect disappeared as the separation reached a dimension equal to the specimen width. The effects of specimen width and thickness are interrelated and affect the net strength through their influence on the development of the crack tip plastic zone.

  11. 14 CFR 121.651 - Takeoff and landing weather minimums: IFR: All certificate holders.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Takeoff and landing weather minimums: IFR... Flight Release Rules § 121.651 Takeoff and landing weather minimums: IFR: All certificate holders. (a) Notwithstanding any clearance from ATC, no pilot may begin a takeoff in an airplane under IFR when the weather...

  12. 14 CFR 121.651 - Takeoff and landing weather minimums: IFR: All certificate holders.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Takeoff and landing weather minimums: IFR... Flight Release Rules § 121.651 Takeoff and landing weather minimums: IFR: All certificate holders. (a) Notwithstanding any clearance from ATC, no pilot may begin a takeoff in an airplane under IFR when the weather...

  13. 14 CFR 121.651 - Takeoff and landing weather minimums: IFR: All certificate holders.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Takeoff and landing weather minimums: IFR... Flight Release Rules § 121.651 Takeoff and landing weather minimums: IFR: All certificate holders. (a) Notwithstanding any clearance from ATC, no pilot may begin a takeoff in an airplane under IFR when the weather...

  14. 14 CFR 121.651 - Takeoff and landing weather minimums: IFR: All certificate holders.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Takeoff and landing weather minimums: IFR... Flight Release Rules § 121.651 Takeoff and landing weather minimums: IFR: All certificate holders. (a) Notwithstanding any clearance from ATC, no pilot may begin a takeoff in an airplane under IFR when the weather...

  15. 14 CFR 121.651 - Takeoff and landing weather minimums: IFR: All certificate holders.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Takeoff and landing weather minimums: IFR... Flight Release Rules § 121.651 Takeoff and landing weather minimums: IFR: All certificate holders. (a) Notwithstanding any clearance from ATC, no pilot may begin a takeoff in an airplane under IFR when the weather...

  16. 10 CFR 26.165 - Testing split specimens and retesting single specimens.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Testing split specimens and retesting single specimens. 26.165 Section 26.165 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories... laboratory or maintained in secure storage at the licensee testing facility, as required by § 26.135(a) and...

  17. Insights into the deformation behavior of the CrMnFeCoNi high-entropy alloy revealed by elevated temperature nanoindentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maier-Kiener, Verena; Schuh, Benjamin; George, Easo P.

    A CrMnFeCoNi high-entropy alloy was investigated by nanoindentation from room temperature to 400 °C in the nanocrystalline state and cast plus homogenized coarse-grained state. In the latter case a < 100 >-orientated grain was selected by electron back scatter diffraction for nanoindentation. It was found that hardness decreases more strongly with increasing temperature than Young’s modulus, especially for the coarse-grained state. The modulus of the nanocrystalline state was slightly higher than that of the coarse-grained one. For the coarse-grained sample a strong thermally activated deformation behavior was found up to 100–150 °C, followed by a diminishing thermally activated contribution atmore » higher testing temperatures. For the nanocrystalline state, different temperature dependent deformation mechanisms are proposed. At low temperatures, the governing processes appear to be similar to those in the coarse-grained sample, but with increasing temperature, dislocation-grain boundary interactions likely become more dominant. Finally, at 400 °C, decomposition of the nanocrystalline alloy causes a further reduction in thermal activation. Furthermore, this is rationalized by a reduction of the deformation controlling internal length scale by precipitate formation in conjunction with a diffusional contribution.« less

  18. Specimen Collection and Submission Manual

    DTIC Science & Technology

    2016-06-01

    immunoassays Specimen: tissue or bone marrow (100 mg); Whole EDTA blood or serum (0.5 ml) Nasopharyngeal or throat swab, dry or in transport medium; Sputum... Syndrome Coronavirus (MERS-CoV) – detection in clinical samples Methodology: molecular Specimen: If possible collect 3 specimen types (lower...guidelines-clinical-specimens.html) Shipping: ship cold on wet ice or ice packs. For delays exceeding 72 hours, ship frozen on dry ice. Turnaround: 1-2

  19. 17 CFR 240.14a-3 - Information to be furnished to security holders.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Information to be furnished to... Information to be furnished to security holders. (a) No solicitation subject to this regulation shall be made..., containing the information specified in Schedule 14A (§ 240.14a-101); (2) A preliminary or definitive written...

  20. Delamination analysis of metal-ceramic multilayer coatings subject to nanoindentation

    DOE PAGES

    Jamison, Ryan Dale; Shen, Yu -Lin

    2016-01-22

    Internal damage has been experimentally observed in aluminum (Al)/silicon carbide (SiC) multilayer coatings subject to nanoindentation loading. Post-indentation characterization has identified that delamination at the coating/substrate interface is the most prominent form of damage. In this study the finite element method is employed to study the effect of delamination on indentation-derived hardness and Young's modulus. The model features alternating Al/SiC nanolayers above a silicon (Si) substrate, in consistence with the actual material system used in earlier experiments. Cohesive elements with a traction–separation relationship are used to facilitate delamination along the coating/substrate interface. Delamination is observed numerically to be sensitive tomore » the critical normal and shear stresses that define the cohesive traction–separation behavior. Axial tensile stress below the edge of indentation contact is found to be the largest contributor to damage initiation and evolution. Delamination results in a decrease in both indentation-derived hardness and Young's modulus. As a result, a unique finding is that delamination can occur during the unloading process of indentation, depending on the loading condition and critical tractions.« less

  1. 75 FR 62345 - Minimum Balance Requirement and Automatic Replenishment Option for Deposit Account Holders

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-08

    ... LIBRARY OF CONGRESS Copyright Office 37 CFR Part 201 [Docket No. RM 2009-4] Minimum Balance... transactions per year; require deposit account holders to maintain a minimum balance in that account; mandate... against the balance instead of sending separate payments with applications and other requests for services...

  2. A new head holder for reducing axial movement and repositioning errors during physiological CT imaging.

    PubMed

    Shrawder, S; Lapin, G D; Allen, C V; Vick, N A; Groothuis, D R

    1994-01-01

    We designed a new head holder for immobilization and repositioning in dynamic CT studies of the brain. A customized thermoplastic face mask and foam head rest were made to restrict movement of the head in all directions, but particularly out of the axial plane (z-movement). This design provided a rigid, detailed mold of the face and back of the head that minimized motion during lengthy CT studies and enabled accurate repositioning of the head for follow-up studies. Markers applied directly to the skin were used to quantify z-movement. When tested on 12 subjects, immobilization was limited to < 2.0 mm under worst-case conditions when the subject was asked to attempt forced movements. Repositioning was accurate to < 1.5 mm when the subject was removed from the head holder and then placed back into it.

  3. 17 CFR 240.14a-3 - Information to be furnished to security holders.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... may provide the information in Article 8 of Regulation S-X (§ 210.8 of this chapter) in lieu of the... 17 Commodity and Securities Exchanges 3 2013-04-01 2013-04-01 false Information to be furnished to... Information to be furnished to security holders. (a) No solicitation subject to this regulation shall be made...

  4. 17 CFR 240.14a-3 - Information to be furnished to security holders.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... may provide the information in Article 8 of Regulation S-X (§ 210.8 of this chapter) in lieu of the... 17 Commodity and Securities Exchanges 3 2012-04-01 2012-04-01 false Information to be furnished to... Information to be furnished to security holders. (a) No solicitation subject to this regulation shall be made...

  5. 17 CFR 240.14a-3 - Information to be furnished to security holders.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... may provide the information in Article 8 of Regulation S-X (§ 210.8 of this chapter) in lieu of the... 17 Commodity and Securities Exchanges 4 2014-04-01 2014-04-01 false Information to be furnished to... Information to be furnished to security holders. (a) No solicitation subject to this regulation shall be made...

  6. 17 CFR 240.14a-3 - Information to be furnished to security holders.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... may provide the information in Article 8 of Regulation S-X (§ 210.8 of this chapter) in lieu of the... 17 Commodity and Securities Exchanges 3 2011-04-01 2011-04-01 false Information to be furnished to... Information to be furnished to security holders. (a) No solicitation subject to this regulation shall be made...

  7. A Flexure-Based Tool Holder for Sub-(micro)m Positioning of a Single Point Cutting Tool on a Four-axis Lathe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bono, M J; Hibbard, R L

    2005-12-05

    A tool holder was designed to facilitate the machining of precision meso-scale components with complex three-dimensional shapes with sub-{micro}m accuracy on a four-axis lathe. A four-axis lathe incorporates a rotary table that allows the cutting tool to swivel with respect to the workpiece to enable the machining of complex workpiece forms, and accurately machining complex meso-scale parts often requires that the cutting tool be aligned precisely along the axis of rotation of the rotary table. The tool holder designed in this study has greatly simplified the process of setting the tool in the correct location with sub-{micro}m precision. The toolmore » holder adjusts the tool position using flexures that were designed using finite element analyses. Two flexures adjust the lateral position of the tool to align the center of the nose of the tool with the axis of rotation of the B-axis, and another flexure adjusts the height of the tool. The flexures are driven by manual micrometer adjusters, each of which provides a minimum increment of motion of 20 nm. This tool holder has simplified the process of setting a tool with sub-{micro}m accuracy, and it has significantly reduced the time required to set a tool.« less

  8. Nanoindentation study of the mechanical behavior of TiO2 nanotube arrays

    NASA Astrophysics Data System (ADS)

    Xu, Y. N.; Liu, M. N.; Wang, M. C.; Oloyede, A.; Bell, J. M.; Yan, C.

    2015-10-01

    Titanium dioxide (TiO2) nanotube arrays are attracting increasing attention for use in solar cells, lithium-ion batteries, and biomedical implants. To take full advantage of their unique physical properties, such arrays need to maintain adequate mechanical integrity in applications. However, the mechanical performance of TiO2 nanotube arrays is not well understood. In this work, we investigate the deformation and failure of TiO2 nanotube arrays using the nanoindentation technique. We found that the load-displacement response of the arrays strongly depends on the indentation depth and indenter shape. Substrate-independent elastic modulus and hardness can be obtained when the indentation depth is less than 2.5% of the array height. The deformation mechanisms of TiO2 nanotube arrays by Berkovich and conical indenters are closely associated with the densification of TiO2 nanotubes under compression. A theoretical model for deformation of the arrays under a large-radius conical indenter is also proposed.

  9. In Situ Measurement of Ground-Surface Flow Resistivity

    NASA Technical Reports Server (NTRS)

    Zuckerwar, A. J.

    1984-01-01

    New instrument allows in situ measurement of flow resistivity on Earth's ground surface. Nonintrusive instrument includes specimen holder inserted into ground. Flow resistivity measured by monitoring compressed air passing through flow-meters; pressure gages record pressure at ground surface. Specimen holder with knife-edged inner and outer cylinders easily driven into ground. Air-stream used in measuring flow resistivity of ground enters through quick-connect fitting and exits through screen and venthole.

  10. [Complaints by private health insurance policy-holders to the Consumer Protection Bureau in Argentina, 2000-2008].

    PubMed

    Luzuriaga, María José; Spinelli, Hugo

    2014-05-01

    This paper analyzes problems experienced by policy-holders of voluntary private health insurance plans in Argentina when insurance companies fail to comply with the Consumer Protection Code. The sample consisted of consumer complaints filed with the Consumer Protection Bureau and rulings by the Bureau from 2000 to 2008. One striking issue was recurrent non-compliance with services included in the Mandatory Medical Program and the companies' attempts to blame policy-holders. According to the study, the lack of an information system hinders scientific studies to adequately address the problem. Thus, a comparison with studies on health insurance in other Latin American countries highlighted the importance of such research, the relationship to health systems, constraints on use and denial of citizens' rights to healthcare, and the increasing judicialization of healthcare provision.

  11. 10 CFR 39.43 - Inspection, maintenance, and opening of a source or source holder.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Inspection, maintenance, and opening of a source or source holder. 39.43 Section 39.43 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY..., for defects before each use to ensure that the equipment is in good working condition and that...

  12. 10 CFR 39.43 - Inspection, maintenance, and opening of a source or source holder.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Inspection, maintenance, and opening of a source or source holder. 39.43 Section 39.43 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY..., for defects before each use to ensure that the equipment is in good working condition and that...

  13. 10 CFR 39.43 - Inspection, maintenance, and opening of a source or source holder.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Inspection, maintenance, and opening of a source or source holder. 39.43 Section 39.43 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY..., for defects before each use to ensure that the equipment is in good working condition and that...

  14. 10 CFR 39.43 - Inspection, maintenance, and opening of a source or source holder.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Inspection, maintenance, and opening of a source or source holder. 39.43 Section 39.43 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY..., for defects before each use to ensure that the equipment is in good working condition and that...

  15. 10 CFR 39.43 - Inspection, maintenance, and opening of a source or source holder.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Inspection, maintenance, and opening of a source or source holder. 39.43 Section 39.43 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY..., for defects before each use to ensure that the equipment is in good working condition and that...

  16. 17 CFR 240.14d-6 - Disclosure of tender offer information to security holders.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Disclosure of tender offer information to security holders. 240.14d-6 Section 240.14d-6 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, SECURITIES EXCHANGE ACT OF 1934 Rules and...

  17. Electrode holder useful in a corrosion testing device

    DOEpatents

    Murphy, R.J. Jr.; Jamison, D.E.

    1986-08-19

    The present invention is directed to an apparatus and method for holding one or more test electrodes of precisely known exposed surface area. The present invention is particularly useful in a device for determining the corrosion properties of the materials from which the test electrodes have been formed. The present invention relates to a device and method for holding the described electrodes wherein the exposed surface area of the electrodes is only infinitesimally decreased. Further, in the present invention the exposed, electrically conductive surface area of the contact devices is small relative to the test electrode surface area. The holder of the present invention conveniently comprises a device for contacting and engaging each test electrode at two point contacts infinitesimally small in relation to the exposed surface area of the electrodes. 4 figs.

  18. Electrode holder useful in a corrosion testing device

    DOEpatents

    Murphy, Jr., Robert J.; Jamison, Dale E.

    1986-01-01

    The present invention is directed to an apparatus and method for holding one or more test electrodes of precisely known exposed surface area. The present invention is particularly useful in a device for determining the corrosion properties of the materials from which the test electrodes have been formed. The present invention relates to a device and method for holding the described electrodes wherein the exposed surface area of the electrodes is only infinitesimally decreased. Further, in the present invention the exposed, electrically conductive surface area of the contact devices is small relative to the test electrode surface area. The holder of the present invention conveniently comprises a device for contacting and engaging each test electrode at two point contacts infinitesimally small in relation to the exposed surface area of the electrodes.

  19. Silicon sample holder for molecular beam epitaxy on pre-fabricated integrated circuits

    NASA Technical Reports Server (NTRS)

    Hoenk, Michael E. (Inventor); Grunthaner, Paula J. (Inventor); Grunthaner, Frank J. (Inventor)

    1994-01-01

    The sample holder of the invention is formed of the same semiconductor crystal as the integrated circuit on which the molecular beam expitaxial process is to be performed. In the preferred embodiment, the sample holder comprises three stacked micro-machined silicon wafers: a silicon base wafer having a square micro-machined center opening corresponding in size and shape to the active area of a CCD imager chip, a silicon center wafer micro-machined as an annulus having radially inwardly pointing fingers whose ends abut the edges of and center the CCD imager chip within the annulus, and a silicon top wafer micro-machined as an annulus having cantilevered membranes which extend over the top of the CCD imager chip. The micro-machined silicon wafers are stacked in the order given above with the CCD imager chip centered in the center wafer and sandwiched between the base and top wafers. The thickness of the center wafer is about 20% less than the thickness of the CCD imager chip. Preferably, four titanium wires, each grasping the edges of the top and base wafers, compress all three wafers together, flexing the cantilever fingers of the top wafer to accommodate the thickness of the CCD imager chip, acting as a spring holding the CCD imager chip in place.

  20. Nanoindentation hardness and atomic force microscope imaging studies of pressure-quenched zirconium metal

    NASA Astrophysics Data System (ADS)

    Catledge, Shane A.; Spencer, Philemon T.; Vohra, Yogesh K.

    2000-11-01

    We have carried out mechanical property measurements on zirconium metal compressed in a diamond anvil cell to 19 GPa at room temperature with subsequent quenching to room pressure. The irreversible transformation from the ambient hexagonal-close-packed phase to the simple hexagonal ω phase (AlB2 structure) is confirmed by synchrotron energy dispersive x-ray diffraction followed by nanoindentation of the pressure-quenched sample. We document an 80% increase in hardness as a consequence of the pressure-induced transformation to the ω phase at room temperature. This is a large increase for a metallic phase transformation and can be attributed to the presence of sp2-hybrid bonds forming graphite-like nets in the (0001) plane of the AlB2 structure. Atomic force microscopy of the indents shows that a plastic deformation of 2 μm in depth was achieved with a force of 200 mN.

  1. Hardness of AISI type 410 martensitic steels after high temperature irradiation via nanoindentation

    NASA Astrophysics Data System (ADS)

    Waseem, Owais Ahmed; Jeong, Jong-Ryul; Park, Byong-Guk; Maeng, Cheol-Soo; Lee, Myoung-Goo; Ryu, Ho Jin

    2017-11-01

    The hardness of irradiated AISI type 410 martensitic steel, which is utilized in structural and magnetic components of nuclear power plants, is investigated in this study. Proton irradiation of AISI type 410 martensitic steel samples was carried out by exposing the samples to 3 MeV protons up to a 1.0 × 1017 p/cm2 fluence level at a representative nuclear reactor coolant temperature of 350 °C. The assessment of deleterious effects of irradiation on the micro-structure and mechanical behavior of the AISI type 410 martensitic steel samples via transmission electron microscopy-energy dispersive spectroscopy and cross-sectional nano-indentation showed no significant variation in the microscopic or mechanical characteristics. These results ensure the integrity of the structural and magnetic components of nuclear reactors made of AISI type 410 martensitic steel under high-temperature irradiation damage levels up to approximately 5.2 × 10-3 dpa.

  2. Hardness and deformation mechanisms of highly elastic carbon nitride thin films as studied by nanoindentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hainsworth, S.V.; Page, T.F.; Sjoestroem, H.

    1997-05-01

    Carbon nitride (CN{sub x}) thin films (0.18 < x < 0.43), deposited by magnetron sputtering of C in a N{sub 2} discharge, have been observed to be extremely resistant to plastic deformation during surface contact (i.e., exhibit a purely elastic response over large strains). Elastic recoveries as high as 90% have been measured by nanoindentation. This paper addresses the problems of estimating Young`s modulus (E) and hardness (H) in such cases and shows how different strategies involving analysis of both loading and unloading curves and measuring the work of indentation each present their own problems. The results of some cyclicmore » contact experiments are also presented and possible deformation mechanisms in the fullerene-like CN{sub x} structures discussed.« less

  3. 76 FR 61999 - Policy Statement: Inappropriate Design Approval Holder (DAH) Restrictions on the Use and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-06

    .... FOR FURTHER INFORMATION CONTACT: John Cerra, Aerospace Engineer, Federal Aviation Administration..., distribution, and use of ICAs, by submitting such written data, views, or arguments to the address or FAX... holder of a design approval to furnish at least one set of complete Instructions for Continued...

  4. 42 CFR 60.53 - Notification to lender or holder of change in enrollment status.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... failure to enroll as scheduled for any academic period as a full-time student, the student's latest known... identify or locate the student. If the school does not know the identity of the current holder of the HEAL... do not exceed one academic term. (Approved by the Office of Management and Budget under control...

  5. 42 CFR 60.53 - Notification to lender or holder of change in enrollment status.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... failure to enroll as scheduled for any academic period as a full-time student, the student's latest known... identify or locate the student. If the school does not know the identity of the current holder of the HEAL... do not exceed one academic term. (Approved by the Office of Management and Budget under control...

  6. 42 CFR 60.53 - Notification to lender or holder of change in enrollment status.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... failure to enroll as scheduled for any academic period as a full-time student, the student's latest known... identify or locate the student. If the school does not know the identity of the current holder of the HEAL... do not exceed one academic term. (Approved by the Office of Management and Budget under control...

  7. An Analysis of Job Evaluation Committee and Job Holder Gender Effects on Job Evaluation.

    ERIC Educational Resources Information Center

    Lewis, Chad T.; Stevens, Cynthia Kay

    1990-01-01

    A total of 204 business students organized in committees evaluated jobs for accountability, knowledge and skills, and mental demands. The same position was rated more highly when held by a male rather than a female, regardless of whether the committee was predominantly male or female. The importance of anonymity of job holders when conducting job…

  8. Effect of Holder pasteurization on macronutrients and immunoglobulin profile of pooled donor human milk.

    PubMed

    Adhisivam, B; Vishnu Bhat, B; Rao, Krishna; Kingsley, S M; Plakkal, Nishad; Palanivel, C

    2018-03-27

    The objective of this study was to study the effect of Holder pasteurization on macronutrients and immunoglobulin profile of pooled donor human milk. This descriptive study was conducted in a Human Milk Bank of a tertiary care teaching institute in south India. Thirty random paired pooled donor human milk samples (before and after pasteurization) were analyzed for macronutrients (protein, fat, carbohydrates) using infrared spectroscopy. Similarly, immunoglobulin profile (IgA and IgG) before and after pasteurization was quantified using ELISA. The mean values of protein, fat, and carbohydrates in pooled donor milk pre-pasteurization were 1.6, 3.6, and 6.1 g/dl compared with post-pasteurization values 1.4, 2.7, and 5.9 g/dl, respectively. Pasteurization reduced protein, fat, and energy content of pooled donor milk by 12.5%, 25%, and 16%, respectively. However, carbohydrates were not significantly reduced. Pasteurization decreased IgA by 30% and IgG by 60%. Holder pasteurization of pooled donor human milk decreases protein, fat, and energy content and also reduces the levels of IgA and IgG.

  9. Cultures of Holder-pasteurized donor human milk after use in a neonatal intensive care unit.

    PubMed

    Cohen, Ronald S; Huang, Chien-Fang Riva; Xiong, Sean C; Sakamoto, Pauline

    2012-08-01

    Current guidelines state that human milk, once thawed, should be kept in a refrigerator for only 24 hours. We cultured Holder-pasteurized donor human milk (DHM) after thawing and refrigeration under clinical conditions. Bottles of pasteurized DHM were thawed and used in a regional level 3 neonatal intensive care unit (NICU) in standard clinical fashion and kept refrigerated when not in use. Once no longer needed clinically, aliquots were cultured for bacteria. In total, 30 bottles were returned for culture; six were excluded from analysis because human milk fortifier had been added, and two had been left out of the refrigerator. The remaining 22 bottles were culture-negative after having been thawed for 7-122 hours. DHM without additives was culture-negative for 24 hours or longer after thawing and routine NICU handling. These data indicate that unfortified Holder-pasteurized DHM handled appropriately and refrigerated remains sterile for 24 hours after thawing and perhaps longer. Further study is needed to confirm this.

  10. Laser-heated rotating specimen autoignition test

    NASA Technical Reports Server (NTRS)

    Au, A. C.

    1988-01-01

    Specimens of 440 C steel were rotated in a chamber pressurized with oxygen gas and heated with a 5-kW CO2 laser to determine the temperature required for autoignition to occur. Tests included exposures of static and rotating (25,000 rpm) specimens in oxygen pressurized to 5.51 MPa, and with focused laser fluences of more than 3.5 billion W/sq m. Specimen surface temperatures were monitored with a scanning infrared camera. Temperature measurement difficulties were experienced due to a problem with internal reflection inside the test chamber; however, posttest specimen examinations confirmed that surface melt (1371 C) was achieved in several tests. No sustained combustion was initiated in any rotating specimen. One static specimen was ignited. Results indicated that conditions necessary for autoignition of 440 C steel are more dependent on specimen geometry and available heat removal mechanisms. Sustained combustion occurred in the ignited static specimen with an estimated 130 C/sec cooling rate due to conduction. The rotating specimens could not sustain combustion due to a greater conductive/convective cooling rate of about 4000 C/sec and ejection of molten material. These results were applied to the Space Shuttle Main Engine (SSME) oxygen turbopump bearings to conclude that the LOX-cooled 440 C steel bearings cannot sustain combustion initiated by skidding friction.

  11. Janka hardness using nonstandard specimens

    Treesearch

    David W. Green; Marshall Begel; William Nelson

    2006-01-01

    Janka hardness determined on 1.5- by 3.5-in. specimens (2×4s) was found to be equivalent to that determined using the 2- by 2-in. specimen specified in ASTM D 143. Data are presented on the relationship between Janka hardness and the strength of clear wood. Analysis of historical data determined using standard specimens indicated no difference between side hardness...

  12. Nondestructive DNA extraction from museum specimens.

    PubMed

    Hofreiter, Michael

    2012-01-01

    Natural history museums around the world hold millions of animal and plant specimens that are potentially amenable to genetic analyses. With more and more populations and species becoming extinct, the importance of these specimens for phylogenetic and phylogeographic analyses is rapidly increasing. However, as most DNA extraction methods damage the specimens, nondestructive extraction methods are useful to balance the demands of molecular biologists, morphologists, and museum curators. Here, I describe a method for nondestructive DNA extraction from bony specimens (i.e., bones and teeth). In this method, the specimens are soaked in extraction buffer, and DNA is then purified from the soaking solution using adsorption to silica. The method reliably yields mitochondrial and often also nuclear DNA. The method has been adapted to DNA extraction from other types of specimens such as arthropods.

  13. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 160A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, B. J.; Miller, D. T.

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 160A which were measured by the Radiation Measurements Laboratory (RML).

  14. A review of chevron-notched fracture specimens

    NASA Technical Reports Server (NTRS)

    Newman, J. C., Jr.

    1984-01-01

    The historical development of chevron notched fracture specimens is reviewed. Stress intensity factors and load line displacement solutions proposed for some of these specimens are compared. The original bend bar configurations up to the present day short rod and bar specimens are reviewed. The results of an analytical round robin that was conducted on chevron-notched specimens are presented. In the round robin, stress-intensity factors for either the chevron notched round rod or square bar specimens were calculated. The consensus stress intensity factor (compliance) solution for these specimens is assessed. The stress intensity factor solutions proposed for three and four point bend chevron notched specimens are reviewed.

  15. Biomechanical Analysis of Hearing in Whales Using Nanoindentation and the Finite Element Method

    NASA Astrophysics Data System (ADS)

    Tubelli, Andrew A.; Zosuls, Aleks; Ketten, Darlene R.; Mountain, David C.

    2011-11-01

    The detailed biomechanics of hearing in baleen whales are almost entirely unknown. As a first step to predicting the audiogram for these species, a linear three-dimensional finite-element model of the minke whale (Balaenoptera acutorostrata) middle ear was developed. A reconstruction of the ear was made from CT scans and imported into a finite element solver. Young's modulus of the bone was estimated via nanoindentation. The middle-ear transfer function was estimated by applying a pressure to the glove finger (the thick, everted equivalent of the tympanic membrane) with velocity calculated at the stapes footplate. It was found that the most sensitive frequencies corresponded with vocalization frequencies. For all frequencies tested, the malleus-incus complex flexed about the anterior process of the malleus and the stapes rotated within the oval window. Results indictae that finite element modeling is a useful approach for studying the mechanics of hearing in species that are difficult to study in vivo.

  16. The mechanical properties of as-grown noncubic organic molecular crystals assessed by nanoindentation

    DOE PAGES

    Taw, Matthew R.; Yeager, John D.; Hooks, Daniel E.; ...

    2017-06-19

    Organic molecular crystals are often noncubic and contain significant steric hindrance within their structure to resist dislocation motion. Plastic deformation in these systems can be imparted during processing (tableting and comminution of powders), and the defect density impacts subsequent properties and performance. This paper measured the elastic and plastic properties of representative monoclinic, orthorhombic, and triclinic molecular crystalline structures using nanoindentation of as-grown sub-mm single crystals. The variation in modulus due to in-plane rotational orientation, relative to a Berkovich tip, was approximately equal to the variation of a given crystal at a fixed orientation. The onset of plasticity occurs consistentlymore » at shear stresses between 1 and 5% of the elastic modulus in all three crystal systems, and the hardness to modulus ratio suggests conventional Berkovich tips do not generate fully self-similar plastic zones in these materials. Finally, this provides guidance for mechanical models of tableting, machining, and property assessment of molecular crystals.« less

  17. Single versus successive pop-in modes in nanoindentation tests of single crystals

    DOE PAGES

    Xia, Yuzhi; Gao, Yanfei; Pharr, George M.; ...

    2016-05-24

    From recent nanoindentation experiments, two types of pop-in modes have been identified: a single pop-in with a large displacement excursion, or a number of pop-ins with comparable and small displacement excursions. Theoretical analyses are developed here to study the roles played by indenter tip radius, pre-existing defect density, heterogeneous nucleation source type, and lattice resistance on the pop-in modes. The evolution of dislocation structures in earlier pop-ins provides input to modeling a stochastic, heterogeneous mechanism that may be responsible for the subsequent pop-ins. It is found that when the first pop-in occurs near theoretical shear stress, the pop-in mode ismore » determined by the lattice resistance and tip radius. When the first pop-in occurs at low shear stress, whether the successive pop-in mode occurs depends on how the heterogeneous dislocation nucleation source density increases as compared to the increase of the total dislocation density. Lastly, the above transitions are found to correlate well with the ratio of indenter tip radius to the mean spacing of dislocation nucleation sources.« less

  18. Nanoindentation investigation of heavy ion irradiated Ti 3(Si,Al)C 2

    NASA Astrophysics Data System (ADS)

    Liu, X. M.; Le Flem, M.; Béchade, J. L.; Monnet, I.

    2010-06-01

    Because of good damage tolerance, thermal stability and interesting mechanical properties, Ti 3SiC 2, belonging to M n+1AX n phases, has been considered as a potential candidate material for applications in the future Gas Fast nuclear Reactors (GFR) such as components of fuel cladding working between 500 °C and 800 °C. However, the outstanding mechanical properties of Ti 3SiC 2 related to a layered microstructure could be impacted by irradiation. In this work, high energy Kr and Xe ion irradiated Ti 3Si 0.95Al 0.05C 2 and Ti 3Si 0.90Al 0.10C 2 samples, provided by IMR Shenyang, Chinese Academy of Science, were characterized by nanoindentation technique. After irradiation at room temperature, an increase in hardness with irradiation dose was highlighted. Nevertheless, some damage tolerance remained because of preservation of the typical MAX layered structure. Irradiations at 300 °C and 500 °C lead to less significant increase suggesting irradiation defect annealing. A complete recovery of the properties at 800 °C seems to be obtained.

  19. Nanoindentation of HMX and Idoxuridine to Determine Mechanical Similarity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burch, Alexandra; Yeager, John; Bahr, David

    Assessing the mechanical behavior (elastic properties, plastic properties, and fracture phenomena) of molecular crystals is often complicated by the difficulty in preparing samples. Pharmaceuticals and energetic materials in particular are often used in composite structures or tablets, where the individual grains can strongly impact the solid behavior. Nanoindentation is a convenient method to experimentally assess these properties, and it is used here to demonstrate the similarity in the mechanical properties of two distinct systems: individual crystals of the explosive cyclotetramethylene tetranitramine (HMX) and the pharmaceutical idoxuridine were tested in their as-precipitated state, and the effective average modulus and hardness (whichmore » can be orientation dependent) were determined. Both exhibit a hardness of 1.0 GPa, with an effective reduced modulus of 25 and 23 GPa for the HMX and idoxuridine, respectively. They also exhibit similar yield point behavior. This indicates idoxuridine may be a suitable mechanical surrogate (or “mock”) for HMX. While the methodology to assess elastic and plastic properties was relatively insensitive to specific crystal orientation (i.e., a uniform distribution in properties was observed for all random crystals tested), the indentation-induced fracture properties appear to be much more sensitive to tip-crystal orientation, and an unloading slope analysis is used to demonstrate the need for further refinement in relating toughness to orientation in these materials with relatively complex slip systems and crystal structures. View Full-Text« less

  20. Nanoindentation of HMX and Idoxuridine to Determine Mechanical Similarity

    DOE PAGES

    Burch, Alexandra; Yeager, John; Bahr, David

    2017-11-01

    Assessing the mechanical behavior (elastic properties, plastic properties, and fracture phenomena) of molecular crystals is often complicated by the difficulty in preparing samples. Pharmaceuticals and energetic materials in particular are often used in composite structures or tablets, where the individual grains can strongly impact the solid behavior. Nanoindentation is a convenient method to experimentally assess these properties, and it is used here to demonstrate the similarity in the mechanical properties of two distinct systems: individual crystals of the explosive cyclotetramethylene tetranitramine (HMX) and the pharmaceutical idoxuridine were tested in their as-precipitated state, and the effective average modulus and hardness (whichmore » can be orientation dependent) were determined. Both exhibit a hardness of 1.0 GPa, with an effective reduced modulus of 25 and 23 GPa for the HMX and idoxuridine, respectively. They also exhibit similar yield point behavior. This indicates idoxuridine may be a suitable mechanical surrogate (or “mock”) for HMX. While the methodology to assess elastic and plastic properties was relatively insensitive to specific crystal orientation (i.e., a uniform distribution in properties was observed for all random crystals tested), the indentation-induced fracture properties appear to be much more sensitive to tip-crystal orientation, and an unloading slope analysis is used to demonstrate the need for further refinement in relating toughness to orientation in these materials with relatively complex slip systems and crystal structures. View Full-Text« less

  1. Modelling the Holderness coast, eastern England: Past, present and future

    NASA Astrophysics Data System (ADS)

    Barkwith, A.; Limber, P. W.; Thomas, C. W.; Murray, A.; Jordan, H. M.; Ellis, M. A.

    2012-12-01

    The Holderness coast of eastern Yorkshire, England, is the most rapidly eroding coastline in Europe. Erosion can locally exceed 10 m in a single year and rates average 0.5 to 3 m yr-1, generally increasing from north to south. Pinned in the north by a chalk headland, the soft till coastline has a characteristic open spiral form terminated by a spit to the south. Erosion currently threatens local communities and infrastructure, including nationally important gas installations. Interventions to restrict local erosion usually result in enhanced erosion in adjacent, unprotected sections of coast, mirroring morphology seen on the large scale. We have initiated a modelling study to investigate the key controls on the form and evolution of this coastline, and its response to climate change, building on the Coastline Evolution Model (CEM) developed at Duke University, NC. We have adapted the CEM to permit an ensemble of simulations to be undertaken, based upon modified offshore wave climates, initial conditions and forcing factors. The CEM follows a standard 1d approach, where the cross-shore is collapsed into a single data point, allowing the planform shoreline shape and dynamics to be simulated. The model facilitates study of a coast with variable erosion rates, and enables simulation of coastline evolution when sediment is supplied from an eroding shoreface. Additionally, the CEM is adapted to use an observed two year, offshore wave climate data set as input. Initial work focussed on reconstruction of current coastline shape from an ensemble of hypothetical early Holocene shoreface positions and past wave climates. First order reconstruction of shoreline shape was achieved using several differing initial conditions and wave climates. For the majority of successful simulations, a steady state was noted for proceeding years, where erosion proceeds at an equal rate along the length of the coast south of the headland. Together with a sensitivity analysis, the derivation of

  2. 27 CFR 70.145 - Purchasers, holders of security interests, mechanic's lienors, and judgment lien creditors.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... security interests, mechanic's lienors, and judgment lien creditors. 70.145 Section 70.145 Alcohol, Tobacco... Lien for Taxes § 70.145 Purchasers, holders of security interests, mechanic's lienors, and judgment... in § 70.143(a) of this part), mechanic's lienor (as defined in § 70.143(b) of this part), or judgment...

  3. 27 CFR 70.145 - Purchasers, holders of security interests, mechanic's lienors, and judgment lien creditors.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... security interests, mechanic's lienors, and judgment lien creditors. 70.145 Section 70.145 Alcohol, Tobacco... Lien for Taxes § 70.145 Purchasers, holders of security interests, mechanic's lienors, and judgment... in § 70.143(a) of this part), mechanic's lienor (as defined in § 70.143(b) of this part), or judgment...

  4. 27 CFR 70.145 - Purchasers, holders of security interests, mechanic's lienors, and judgment lien creditors.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... security interests, mechanic's lienors, and judgment lien creditors. 70.145 Section 70.145 Alcohol, Tobacco... Lien for Taxes § 70.145 Purchasers, holders of security interests, mechanic's lienors, and judgment... in § 70.143(a) of this part), mechanic's lienor (as defined in § 70.143(b) of this part), or judgment...

  5. 27 CFR 70.145 - Purchasers, holders of security interests, mechanic's lienors, and judgment lien creditors.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... security interests, mechanic's lienors, and judgment lien creditors. 70.145 Section 70.145 Alcohol, Tobacco... Lien for Taxes § 70.145 Purchasers, holders of security interests, mechanic's lienors, and judgment... in § 70.143(a) of this part), mechanic's lienor (as defined in § 70.143(b) of this part), or judgment...

  6. 27 CFR 70.145 - Purchasers, holders of security interests, mechanic's lienors, and judgment lien creditors.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... security interests, mechanic's lienors, and judgment lien creditors. 70.145 Section 70.145 Alcohol, Tobacco... Lien for Taxes § 70.145 Purchasers, holders of security interests, mechanic's lienors, and judgment... in § 70.143(a) of this part), mechanic's lienor (as defined in § 70.143(b) of this part), or judgment...

  7. The Two-Year College as a First Choice, Second Chance Institution for Baccalaureate-Degree Holders

    ERIC Educational Resources Information Center

    Townsend, Barbara K.

    2009-01-01

    This study focused on degree-seeking baccalaureate-degree holders at one two-year technical institute in the Midsouth to determine why they chose to study at the two-year college and how they compared their two-year college experience with their baccalaureate educational experience. Findings indicated the technical college was their first choice…

  8. 42 CFR 60.42 - Records, reports, inspection, and audit requirements for HEAL lenders and holders.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... must maintain for each borrower a payment history showing the date and amount of each payment received... lender or holder must also maintain for each loan a collection history showing the date and subject of... original copy of an unpaid promissory note, but may store all other records in microform or computer format...

  9. 42 CFR 60.42 - Records, reports, inspection, and audit requirements for HEAL lenders and holders.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... must maintain for each borrower a payment history showing the date and amount of each payment received... lender or holder must also maintain for each loan a collection history showing the date and subject of... original copy of an unpaid promissory note, but may store all other records in microform or computer format...

  10. 42 CFR 60.42 - Records, reports, inspection, and audit requirements for HEAL lenders and holders.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... must maintain for each borrower a payment history showing the date and amount of each payment received... lender or holder must also maintain for each loan a collection history showing the date and subject of... original copy of an unpaid promissory note, but may store all other records in microform or computer format...

  11. 10 CFR 26.135 - Split specimens.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Split specimens. 26.135 Section 26.135 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.135 Split specimens. (a) If the FFD program follows split-specimen procedures, as described in § 26.113, the licensee testing...

  12. 10 CFR 26.135 - Split specimens.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Split specimens. 26.135 Section 26.135 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.135 Split specimens. (a) If the FFD program follows split-specimen procedures, as described in § 26.113, the licensee testing...

  13. 10 CFR 26.135 - Split specimens.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Split specimens. 26.135 Section 26.135 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.135 Split specimens. (a) If the FFD program follows split-specimen procedures, as described in § 26.113, the licensee testing...

  14. 10 CFR 26.135 - Split specimens.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Split specimens. 26.135 Section 26.135 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.135 Split specimens. (a) If the FFD program follows split-specimen procedures, as described in § 26.113, the licensee testing...

  15. 10 CFR 26.135 - Split specimens.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Split specimens. 26.135 Section 26.135 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.135 Split specimens. (a) If the FFD program follows split-specimen procedures, as described in § 26.113, the licensee testing...

  16. Effect of Holder pasteurization and frozen storage on macronutrients and energy content of breast milk.

    PubMed

    García-Lara, Nadia Raquel; Vieco, Diana Escuder; De la Cruz-Bértolo, Javier; Lora-Pablos, David; Velasco, Noelia Ureta; Pallás-Alonso, Carmen Rosa

    2013-09-01

    The aim of this study was to explore the effect of Holder pasteurization and frozen storage at -20°C after pasteurization on fat, total nitrogen, lactose, and energy content of breast milk. Both procedures are routinely practiced in human milk banks. A total of 34 samples of frozen breast milk, donated by 28 women, were collected. Once thawed, an aliquot of each sample was analyzed before pasteurization; the remaining milk was pasteurized (Holder method) and split into 8 aliquots. One aliquot was analyzed after pasteurization and the remainder frozen at -20°C and analyzed 30, 60, 90, 120, and 180 days later. For every aliquot, fat, total nitrogen, lactose, and energy content were determined using the device human Milk Analyzer. We observed a significant reduction in fat (3.5%; -0.17 (-0.29; -0.04) g/dL) and energy content (2.8%; -2.03 (-3.60; -0.46) g/dL) after pasteurization. A significant decrease over time was observed for fat, lactose and energy content. No significant changes were observed for nitrogen content. Mean differences between day 0 postpasteurization and day 180 were -0.13 (-0.21; -0.06) g/dL for fat, -0.08 (-0.13; -0.03) g/dL for lactose, and -1.55 (-2.38; -0.71) kcal/dL for energy content. The relative decreases were 2.8%, 1.7%, and 2.2%, respectively. Overall (postpasteurization + frozen storage), a 6.2% and 5% decrease were observed for fat and energy, respectively. Holder pasteurization decreased fat and energy content of human milk. Frozen storage at -20°C of pasteurized milk significantly reduced fat, lactose, and energy content of human milk.

  17. Vise holds specimens for microscope

    NASA Technical Reports Server (NTRS)

    Greule, W. N.

    1980-01-01

    Convenient, miniature, spring-loaded clamp holds specimens for scanning electron microscope. Clamp is made out of nesting sections of studded angle-aluminum. Specimens are easier to mount and dismount with vise than with conductive adhesive or paint.

  18. Influence of Specimen Preparation and Specimen Size on Composite Transverse Tensile Strength and Scatter

    NASA Technical Reports Server (NTRS)

    OBrien, T. Kevin; Chawan, Arun D.; DeMarco, Kevin; Paris, Isabelle

    2001-01-01

    The influence of specimen polishing, configuration, and size on the transverse tension strength of two glass-epoxy materials, and one carbon-epoxy material, loaded in three and four point bending was evaluated. Polishing machined edges, arid/or tension side failure surfaces, was detrimental to specimen strength characterization instead of yielding a higher, more accurate, strength as a result of removing inherent manufacture and handling flaws. Transverse tension strength was typically lower for longer span lengths due to the classical weakest link effect. However, strength was less sensitive to volume changes achieved by increasing specimen width. The Weibull scaling law typically over-predicted changes in transverse tension strengths in three point bend tests and under-predicted changes in transverse tension strengths in four point bend tests. Furthermore, the Weibull slope varied with specimen configuration, volume, and sample size. Hence, this scaling law was not adequate for predicting transverse tension strength of heterogeneous, fiber-reinforced, polymer matrix composites.

  19. Characterization of Mechanical Properties of Nuclear Graphite Using Subsize Specimens and Reusing Tested Specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ji Hyun, Yoon; Byun, Thak Sang; Strizak, Joe P

    2011-01-01

    The mechanical properties of NBG-18 nuclear grade graphite have been characterized using small specimen test techniques and statistical treatment on the test results. New fracture strength and toughness test techniques were developed to use subsize cylindrical specimens with glued heads and to reuse their broken halves. Three sets of subsize cylindrical specimens with the different diameters of 4 mm, 8 mm, and 12 mm were tested to obtain tensile fracture strength. The longer piece of the broken halves was cracked from side surfaces and tested under three-point bend loading to obtain fracture toughness. Both the strength and fracture toughness datamore » were analyzed using Weibull distribution models focusing on size effect. The mean fracture strength decreased from 22.9 MPa to 21.5 MPa as the diameter increased from 4 mm to 12 mm, and the mean strength of 15.9 mm diameter standard specimen, 20.9 MPa, was on the extended trend line. These fracture strength data indicate that in the given diameter range the size effect is not significant and much smaller than that predicted by the Weibull statistics-based model. Further, no noticeable size effect existed in the fracture toughness data, whose mean values were in a narrow range of 1.21 1.26 MPa. The Weibull moduli measured for fracture strength and fracture toughness datasets were around 10. It is therefore believed that the small or negligible size effect enables to use the subsize specimens and that the new fracture toughness test method to reuse the broken specimens to help minimize irradiation space and radioactive waste.« less

  20. Evaluation of the effect of a laparoscopic robotized needle holder on ergonomics and skills.

    PubMed

    Bensignor, Thierry; Morel, Guillaume; Reversat, David; Fuks, David; Gayet, Brice

    2016-02-01

    Laparoscopy generates technical and ergonomics difficulties due to limited degrees of freedom (DOF) of forceps. To reduce this limitation, a new 5-mm robotized needle holder with two intracorporeal DOF, Jaimy(®), has been developed. The aim of this study was to evaluate its effects on ergonomics and skills. Fourteen surgeons including eight senior and six residents were crossover randomized and stratified based on experience. Three suturing tasks were performed with both Jaimy(®) and a classic needle holder (NH): task 1: Peg-Board; task 2: hexagonal suture; task 3: frontal suture. Postural ergonomics of the dominant arm were evaluated with an ergonomics score (RULA score) thanks to motion capture, and muscular ergonomics with electromyography of six muscular groups (flexor and extensor carpis, biceps, triceps, deltoid, trapeze). Performance outcomes are a quantitative and qualitative score, and skills outcomes are the measurement of the number of movements and the path length travelled by the instrument. The RULA score showed a statistically improved posture with Jaimy(®) (p < 0.001). The cumulative muscular workload (CMW) of four muscles was not different. However, the CMW was in favor of the NH for the flexor carpi ulnaris (p < 0.001) and the triceps (p = 0.027). The number of movements was not different (p = 0.39) although the path length was shorter with Jaimy(®) (p = 0.012). The score for task 1 was in favor of the NH (p = 0.006) with a higher quantity score. Task 2 score was not different (p = 0.086): The quality part of the score was in favor of Jaimy(®) (p = 0.009) and the quantity part was higher with the NH (p = 0.04). The score for task 3 was higher with Jaimy(®) (p = 0.001). This study suggests that the use of a robotized needle holder improves both posture and the quality of laparoscopic sutures.