Rhodes, Victoria L; Thomas, Matthew B; Michel, Kristin
2018-08-01
The Toll pathway is a central regulator of antifungal immunity in insects. In mosquitoes, the Toll pathway affects infections with the fungal entomopathogen, Beauveria bassiana, which is considered a potential mosquito biopesticide. We report here the use of B. bassiana strain I93-825 in Anopheles gambiae to analyze the impact of Toll pathway modulation on mosquito survival. Exposure to a narrow dose range of conidia by direct contact decreased mosquito longevity and median survival. In addition, fungal exposure dose correlated positively and linearly with hazard ratio. Increased Toll signaling by knockdown of its inhibitor, cactus, decreased survivorship of uninfected females, increased mosquito survival after low dose B. bassiana exposure, but had little effect following exposure to higher doses. This observed trade-off could have implications for development of B. bassiana as a prospective vector control tool. On the one hand, selection for small increases in mosquito immune signaling across a narrow dose range could impair efficacy of B. bassiana. On the other hand, costs of immunity and the capacity for higher doses of fungus to overwhelm immune responses could limit evolution of resistance. Copyright © 2018 Elsevier Ltd. All rights reserved.
Midazolam: An Improved Anticonvulsant Treatment for Nerve Agent-Induced Seizures
2002-01-01
variety of compounds that different authors had championed as being capable of stopping or moderating nerve agent seizures (e.g., memantine , clonidine...e.g., memantine , neuroactive steroids; EEG seizures were still evident) or required such a narrow dose range or specific treatment conditions that
Radulović, Niko; Dorđević, Nevenka; Denić, Marija; Pinheiro, Mariana Martins Gomes; Fernandes, Patricia Dias; Boylan, Fabio
2012-02-01
2-Pentylpiperidine, named conmaculatin, a novel volatile alkaloid related to coniine was identified from the renowned toxic weed Conium maculatum L. (Apiaceae). The structure of conmaculatin was corroborated by synthesis (8 steps starting from cyclohexanol, overall yield 12%). Conmaculatin's strong peripheral and central antinociceptive activity in mice was observed in a narrow dose range (10-20mg/kg). It was found to be lethal in doses higher than 20mg/kg. Copyright © 2011 Elsevier Ltd. All rights reserved.
Plasma-Filled Rod-Pinch Diode Research on Gamble II
2007-06-01
by the dashed red line in Fig. 3. CaF2 thermoluminescent dosimeters ( TLDs ) located on the front surface of the rolled edge measure the dose. The...half-maximum line-spread function] and high dose [23 rad(CaF2) at 1 m] with 1-2 MeV electron energies are unique capabilities that the PFRP offers...for radiographic imaging in this electron -energy range. The source distribution has a narrow central peak that can enhance the spatial resolution
Estimating thyroid dose in pediatric CT exams from surface dose measurement
NASA Astrophysics Data System (ADS)
Al-Senan, Rani; Mueller, Deborah L.; Hatab, Mustapha R.
2012-07-01
The purpose of this study was to investigate the possibility of estimating pediatric thyroid doses from CT using surface neck doses. Optically stimulated luminescence dosimeters were used to measure the neck surface dose of 25 children ranging in ages between one and three years old. The neck circumference for each child was measured. The relationship between obtained surface doses and thyroid dose was studied using acrylic phantoms of various sizes and with holes of different depths. The ratios of hole-to-surface doses were used to convert patients' surface dose to thyroid dose. ImPACT software was utilized to calculate thyroid dose after applying the appropriate age correction factors. A paired t-test was performed to compare thyroid doses from our approach and ImPACT. The ratio of thyroid to surface dose was found to be 1.1. Thyroid doses ranged from 20 to 80 mGy. Comparison showed no statistical significance (p = 0.18). In addition, the average of surface dose variation along the z-axis in helical scans was studied and found to range between 5% (in 10 cm diameter phantom/24 mm collimation/pitch 1.0) and 8% (in 16 cm diameter phantom/12 mm collimation/pitch 0.7). We conclude that surface dose is an acceptable predictor for pediatric thyroid dose from CT. The uncertainty due to surface dose variability may be reduced if narrower collimation is used with a pitch factor close to 1.0. Also, the results did not show any effect of thyroid depth on the measured dose.
Proposed linear energy transfer areal detector for protons using radiochromic film.
Mayer, Rulon; Lin, Liyong; Fager, Marcus; Douglas, Dan; McDonough, James; Carabe, Alejandro
2015-04-01
Radiation therapy depends on predictably and reliably delivering dose to tumors and sparing normal tissues. Protons with kinetic energy of a few hundred MeV can selectively deposit dose to deep seated tumors without an exit dose, unlike x-rays. The better dose distribution is attributed to a phenomenon known as the Bragg peak. The Bragg peak is due to relatively high energy deposition within a given distance or high Linear Energy Transfer (LET). In addition, biological response to radiation depends on the dose, dose rate, and localized energy deposition patterns or LET. At present, the LET can only be measured at a given fixed point and the LET spatial distribution can only be inferred from calculations. The goal of this study is to develop and test a method to measure LET over extended areas. Traditionally, radiochromic films are used to measure dose distribution but not for LET distribution. We report the first use of these films for measuring the spatial distribution of the LET deposited by protons. The radiochromic film sensitivity diminishes for large LET. A mathematical model correlating the film sensitivity and LET is presented to justify relating LET and radiochromic film relative sensitivity. Protons were directed parallel to radiochromic film sandwiched between solid water slabs. This study proposes the scaled-normalized difference (SND) between the Treatment Planning system (TPS) and measured dose as the metric describing the LET. The SND is correlated with a Monte Carlo (MC) calculation of the LET spatial distribution for a large range of SNDs. A polynomial fit between the SND and MC LET is generated for protons having a single range of 20 cm with narrow Bragg peak. Coefficients from these fitted polynomial fits were applied to measured proton dose distributions with a variety of ranges. An identical procedure was applied to the protons deposited from Spread Out Bragg Peak and modulated by 5 cm. Gamma analysis is a method for comparing the calculated LET with the LET measured using radiochromic film at the pixel level over extended areas. Failure rates using gamma analysis are calculated for areas in the dose distribution using parameters of 25% of MC LET and 3 mm. The processed dose distributions find 5%-10% failure rates for the narrow 12.5 and 15 cm proton ranges and 10%-15% for proton ranges of 15, 17.5, and 20 cm and modulated by 5 cm. It is found through gamma analysis that the measured proton energy deposition in radiochromic film and TPS can be used to determine LET. This modified film dosimetry provides an experimental areal LET measurement that can verify MC calculations, support LET point measurements, possibly enhance biologically based proton treatment planning, and determine the polymerization process within the radiochromic film.
Impact of Monoenergetic Photon Sources on Nonproliferation Applications Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geddes, Cameron; Ludewigt, Bernhard; Valentine, John
Near-monoenergetic photon sources (MPSs) have the potential to improve sensitivity at greatly reduced dose in existing applications and enable new capabilities in other applications, particularly where passive signatures do not penetrate or are insufficiently accurate. MPS advantages include the ability to select energy, energy spread, flux, and pulse structures to deliver only the photons needed for the application, while suppressing extraneous dose and background. Some MPSs also offer narrow angular divergence photon beams which can target dose and/or mitigate scattering contributions to image contrast degradation. Current bremsstrahlung photon sources (e.g., linacs and betatrons) produce photons over a broad range ofmore » energies, thus delivering unnecessary dose that in some cases also interferes with the signature to be detected and/or restricts operations. Current sources must be collimated (reducing flux) to generate narrow divergence beams. While MPSs can in principle resolve these issues, they remain at relatively low TRL status. Candidate MPS technologies for nonproliferation applications are now being developed, each of which has different properties (e.g. broad vs. narrow angular divergence). Within each technology, source parameters trade off against one another (e.g. flux vs. energy spread), representing a large operation space. This report describes a broad survey of potential applications, identification of high priority applications, and detailed simulations addressing those priority applications. Requirements were derived for each application, and analysis and simulations were conducted to define MPS parameters that deliver benefit. The results can inform targeting of MPS development to deliver strong impact relative to current systems.« less
Selby, P. J.; Lopes, N.; Mundy, J.; Crofts, M.; Millar, J. L.; McElwain, T. J.
1987-01-01
A small pre-treatment 'priming' dose of cyclophosphamide will reduce gut damage due to high dose i.v. melphalan in mice and sheep but efforts to demonstrate this effect in man have been hampered by difficulty in the measurement of gut damage. We have evaluated the 51CR EDTA absorption test, a new method for measuring intestinal permeability, as a means of assessing damage due to high dose melphalan. The test was reliable, with a narrow normal range, easy to use and well tolerated. It detected an increase in intestinal permeability after high dose melphalan with a maximum occurring between 9 and 15 days after treatment and subsequently returning to normal. It was shown in 19 patients that a pre-treatment dose of cyclophosphamide was capable of significantly reducing the abnormalities in intestinal permeability which resulted from high dose melphalan. PMID:3111515
Radon Exposure and the Definition of Low Doses-The Problem of Spatial Dose Distribution.
Madas, Balázs G
2016-07-01
Investigating the health effects of low doses of ionizing radiation is considered to be one of the most important fields in radiological protection research. Although the definition of low dose given by a dose range seems to be clear, it leaves some open questions. For example, the time frame and the target volume in which absorbed dose is measured have to be defined. While dose rate is considered in the current system of radiological protection, the same cancer risk is associated with all exposures, resulting in a given amount of energy absorbed by a single target cell or distributed among all the target cells of a given organ. However, the biological effects and so the health consequences of these extreme exposure scenarios are unlikely to be the same. Due to the heterogeneous deposition of radon progeny within the lungs, heterogeneous radiation exposure becomes a practical issue in radiological protection. While the macroscopic dose is still within the low dose range, local tissue doses on the order of Grays can be reached in the most exposed parts of the bronchial airways. It can be concluded that progress in low dose research needs not only low dose but also high dose experiments where small parts of a biological sample receive doses on the order of Grays, while the average dose over the whole sample remains low. A narrow interpretation of low dose research might exclude investigations with high relevance to radiological protection. Therefore, studies important to radiological protection should be performed in the frame of low dose research even if the applied doses do not fit in the dose range used for the definition of low doses.
Proposed linear energy transfer areal detector for protons using radiochromic film
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayer, Rulon; Lin, Liyong; Fager, Marcus
2015-04-15
Radiation therapy depends on predictably and reliably delivering dose to tumors and sparing normal tissues. Protons with kinetic energy of a few hundred MeV can selectively deposit dose to deep seated tumors without an exit dose, unlike x-rays. The better dose distribution is attributed to a phenomenon known as the Bragg peak. The Bragg peak is due to relatively high energy deposition within a given distance or high Linear Energy Transfer (LET). In addition, biological response to radiation depends on the dose, dose rate, and localized energy deposition patterns or LET. At present, the LET can only be measured atmore » a given fixed point and the LET spatial distribution can only be inferred from calculations. The goal of this study is to develop and test a method to measure LET over extended areas. Traditionally, radiochromic films are used to measure dose distribution but not for LET distribution. We report the first use of these films for measuring the spatial distribution of the LET deposited by protons. The radiochromic film sensitivity diminishes for large LET. A mathematical model correlating the film sensitivity and LET is presented to justify relating LET and radiochromic film relative sensitivity. Protons were directed parallel to radiochromic film sandwiched between solid water slabs. This study proposes the scaled-normalized difference (SND) between the Treatment Planning system (TPS) and measured dose as the metric describing the LET. The SND is correlated with a Monte Carlo (MC) calculation of the LET spatial distribution for a large range of SNDs. A polynomial fit between the SND and MC LET is generated for protons having a single range of 20 cm with narrow Bragg peak. Coefficients from these fitted polynomial fits were applied to measured proton dose distributions with a variety of ranges. An identical procedure was applied to the protons deposited from Spread Out Bragg Peak and modulated by 5 cm. Gamma analysis is a method for comparing the calculated LET with the LET measured using radiochromic film at the pixel level over extended areas. Failure rates using gamma analysis are calculated for areas in the dose distribution using parameters of 25% of MC LET and 3 mm. The processed dose distributions find 5%–10% failure rates for the narrow 12.5 and 15 cm proton ranges and 10%–15% for proton ranges of 15, 17.5, and 20 cm and modulated by 5 cm. It is found through gamma analysis that the measured proton energy deposition in radiochromic film and TPS can be used to determine LET. This modified film dosimetry provides an experimental areal LET measurement that can verify MC calculations, support LET point measurements, possibly enhance biologically based proton treatment planning, and determine the polymerization process within the radiochromic film.« less
EPR and photoluminescence study of irradiated anion-defective alumina single crystals
NASA Astrophysics Data System (ADS)
Kortov, V. S.; Ananchenko, D. V.; Konev, S. F.; Pustovarov, V. A.
2017-09-01
Electron paramagnetic resonance (EPR) and photoluminescence (PL) spectra of anion-defective alumina single crystals were measured. Exposure to a dose 10 Gy-1 kGy causes isotropic EPR signal of a complex form, this signal contains narrow and broad components. At the same time, in the PL spectrum alongside with a band of F+-centers (3.8 eV) an additional emission band with the maximum of 2.25 eV is registered. This band corresponds to aggregate F22+-centers which were create under irradiation. By comparing measurements in EPR and PL spectra with further stepped annealing in the temperature range of 773-1473 K of the samples exposed to the same doses, we were able to conclude that a narrow component of isotropic EPR signal is associated with the formation of paramagnetic F22+-centers under irradiation. A wide component can be caused by deep hole traps which are created by a complex defect (VAl2- - F+) with a localized hole.
Korner, P I; Angus, J A
1992-01-01
The average internal radius (ri) of the resistance vessels of the hindquarter (HQ) bed was narrower in renovascular and genetic hypertension than in normotensive controls. The narrowing was approximately uniform over the full range of vasomotor tone, which accounted for the bed's property as an 'amplifier' of vascular resistance (R) (increased slope (S) of the dose-R response curve) and for the elevated R at maximum dilatation (Rmin). In the model we examined the effects on the dose-R curve parameters of altering wall/internal radius (w/ri) ratio, ri and wall 'stiffness' one at a time, whilst the others were held constant: only narrowing of ri led to increases in both S and Rmin; with hypertrophy alone, S increased but Rmin was reduced, whilst increased wall stiffness increased Rmin but lowered S. Thus, for hypertrophy to be associated with rises of both S and Rmin, it must be linked to lumen narrowing, to increased wall stiffness, or to both. Preferential deposition of new material towards the lumen will link hypertrophy to narrowing. It has been suggested that narrowing can occur without hypertrophy ('remodelling'). In the model an increase of only 1-2% WV was required to produce rises in w/ri of congruent to 30-50% when associated with congruent to 10-15% reduction in ri, which is close to the limit of detection. From the literature, the sites of greater narrowing in hypertension extend down to small arteries and large arterioles. The rise in BP upstream from those sites, due to the vascular amplifier, offsets the down-stream effects of vascular narrowing on blood flow and this negative feedback system helps to maintain elevation of BP at a stable level. We also examined developmental rise in R between 4 and 50 weeks, which affected SHR and WKY in the same proportion: structural factors (vascular length of larger arteries, 'rarefaction' of arterioles and capillaries) accounted for only about half the rise in R, and the remainder was probably due to developmental changes in muscle function.
Energy spectrum control for modulated proton beams.
Hsi, Wen C; Moyers, Michael F; Nichiporov, Dmitri; Anferov, Vladimir; Wolanski, Mark; Allgower, Chris E; Farr, Jonathan B; Mascia, Anthony E; Schreuder, Andries N
2009-06-01
In proton therapy delivered with range modulated beams, the energy spectrum of protons entering the delivery nozzle can affect the dose uniformity within the target region and the dose gradient around its periphery. For a cyclotron with a fixed extraction energy, a rangeshifter is used to change the energy but this produces increasing energy spreads for decreasing energies. This study investigated the magnitude of the effects of different energy spreads on dose uniformity and distal edge dose gradient and determined the limits for controlling the incident spectrum. A multilayer Faraday cup (MLFC) was calibrated against depth dose curves measured in water for nonmodulated beams with various incident spectra. Depth dose curves were measured in a water phantom and in a multilayer ionization chamber detector for modulated beams using different incident energy spreads. Some nozzle entrance energy spectra can produce unacceptable dose nonuniformities of up to +/-21% over the modulated region. For modulated beams and small beam ranges, the width of the distal penumbra can vary by a factor of 2.5. When the energy spread was controlled within the defined limits, the dose nonuniformity was less than +/-3%. To facilitate understanding of the results, the data were compared to the measured and Monte Carlo calculated data from a variable extraction energy synchrotron which has a narrow spectrum for all energies. Dose uniformity is only maintained within prescription limits when the energy spread is controlled. At low energies, a large spread can be beneficial for extending the energy range at which a single range modulator device can be used. An MLFC can be used as part of a feedback to provide specified energy spreads for different energies.
UV inactivation of pathogenic and indicator microorganisms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, J.C.; Ossoff, S.F.; Lobe, D.C.
1985-06-01
Survival was measured as a function of the dose of germicidal UV light for the bacteria Escherichia coli, Salmonella typhi, Shigella sonnei, Streptococcus faecalis, Staphylococcus aureus, and Bacillus subtilis spores, the enteric viruses poliovirus type 1 and simian rotavirus SA11, the cysts of the protozoan Acanthamoeba castellanii, as well as for total coliforms and standard plate count microorganisms from secondary effluent. The doses of UV light necessary for a 99.9% inactivation of the cultured vegetative bacteria, total coliforms, and standard plate count microorganisms were comparable. However, the viruses, the bacterial spores, and the amoebic cysts required about 3 to 4more » times, 9 times, and 15 times, respectively, the dose required for E. coli. These ratios covered a narrower relative dose range than that previously reported for chlorine disinfection of E. coli, viruses, spores, and cysts.« less
Vancomycin Dosing in Obese Patients: Special Considerations and Novel Dosing Strategies.
Durand, Cheryl; Bylo, Mary; Howard, Brian; Belliveau, Paul
2018-06-01
To review the literature regarding vancomycin pharmacokinetics in obese patients and strategies used to improve dosing in this population. PubMed, EMBASE (1974 to November 2017), and Google Scholar searches were conducted using the search terms vancomycin, obese, obesity, pharmacokinetics, strategy, and dosing. Additional articles were selected from reference lists of selected studies. Included articles were those published in English with a primary focus on vancomycin pharmacokinetic parameters in obese patients and practical vancomycin dosing strategies, clinical experiences, or challenges of dosing vancomycin in this population. Volume of distribution and clearance are the pharmacokinetic parameters that most often affect vancomycin dosing in obese patients; both are increased in this population. Challenges with dosing in obese patients include inconsistent and inadequate dosing, observations that the obese population may not be homogeneous, and reports of an increased likelihood of supratherapeutic trough concentrations. Investigators have revised and developed dosing and monitoring protocols to address these challenges. These approaches improved target trough attainment to varying degrees. Some of the vancomycin dosing approaches provided promising results in obese patients, but there were notable differences in methods used to develop these approaches, and sample sizes were small. Although some approaches can be considered for validation in individual institutions, further research is warranted. This may include validating approaches in larger populations with narrower obesity severity ranges, investigating target attainment in indication-specific target ranges, and evaluating the impact of different dosing weights and methods of creatinine clearance calculation.
Craven, Meghan; Frank, Graeme R
2018-06-27
Congenital hypothyroidism (CH) is the most common preventable cause of intellectual disability. The recommended starting dose of levothyroxine (LT4) is between 10 and 15 μg/kg, an extremely wide range. We hypothesized that a sizable proportion of newborns treated for CH at the higher end of the dosage range become biochemically hyperthyroid at a follow-up visit. This study is a retrospective chart review of infants with CH between 2002 and 2012. Of the 104 patients included in this analysis, the average age at diagnosis was 11 days and the average starting dose of LT4 was 12±2.5 μg/kg. At follow-up, 36.5% required a dose reduction because of iatrogenic hyperthyroxinemia, 51% required no dose adjustment and 12.5% required a dose increase due to an elevated thyroid stimulating hormone (TSH). The starting doses of LT4 for those requiring a dose reduction, those not requiring an adjustment and those requiring an increase in the dose were 13.2±2.4, 11.5±2.1 and 10.3±2.6 μg/kg/day, respectively (p≤0.0001). Of the 34% of infants treated with an initial dose of >12.5 μg/day, 57.1% required a dose reduction at follow-up, compared to 26.1% of those whose initial starting dose was ≤12.5 μg/kg/day (p=0.007). Following the guidelines for initiating therapy for CH, 36.5% of the infants required a dose reduction for iatrogenic hyperthyroxinemia. These infants received a higher dose of LT4 than the infants who either required no adjustment or required an increase in the dose. A narrower range for initial dosing in CH may be appropriate.
Nariyama, Nobuteru
2017-12-01
Scanning of dosimeters facilitates dose distribution measurements with fine spatial resolutions. This paper presents a method of conversion of the scanning results to water-dose profiles and provides an experimental verification. An Advanced Markus chamber and a diamond detector were scanned at a resolution of 6 μm near the beam edges during irradiation with a 25-μm-wide white narrow x-ray beam from a synchrotron radiation source. For comparison, GafChromic films HD-810 and HD-V2 were also irradiated. The conversion procedure for the water dose values was simulated with Monte Carlo photon-electron transport code as a function of the x-ray incidence position. This method was deduced from nonstandard beam reference-dosimetry protocols used for high-energy x-rays. Among the calculated nonstandard beam correction factors, P wall , which is the ratio of the absorbed dose in the sensitive volume of the chamber with water wall to that with a polymethyl methacrylate wall, was found to be the most influential correction factor in most conditions. The total correction factor ranged from 1.7 to 2.7 for the Advanced Markus chamber and from 1.15 to 1.86 for the diamond detector as a function of the x-ray incidence position. The water dose values obtained with the Advanced Markus chamber and the HD-810 film were in agreement in the vicinity of the beam, within 35% and 18% for the upper and lower sides of the beam respectively. The beam width obtained from the diamond detector was greater, and the doses out of the beam were smaller than the doses of the others. The comparison between the Advanced Markus chamber and HD-810 revealed that the dose obtained with the scanned chamber could be converted to the water dose around the beam by applying nonstandard beam reference-dosimetry protocols. © 2017 American Association of Physicists in Medicine.
Sookpeng, S; Martin, C J; Gentle, D J; Lopez-Gonzalez, M R
2014-03-01
Automatic tube current modulation (ATCM) systems are now used for the majority of CT scans. The principles of ATCM operation are different in CT scanners from different manufacturers. Toshiba and GE scanners base the current modulation on a target noise setting, while Philips and Siemens scanners use reference image and reference mAs concepts respectively. Knowledge of the relationships between patient size, dose and image noise are important for CT patient dose optimisation. In this study, the CT patient doses were surveyed for 14 CT scanners from four different CT scanner manufacturers. The patient cross sectional area, the tube current modulation and the image noise from the CT images were analysed using in-house software. The Toshiba and GE scanner results showed that noise levels are relatively constant but tube currents are dependent on patient size. As a result of this there is a wide range in tube current values across different patient sizes, and doses for large patients are significantly higher in these scanners. In contrast, in the Philips and Siemens scanners, tube currents are less dependent on patient size, the range in tube current is narrower, and the doses for larger patients are not as high. Image noise is more dependent on the patient size.
Ohnishi, S; Odano, N; Nariyama, N; Saito, K
2004-01-01
In usual personal dosimetry, whole body irradiation is assumed. However, the opportunity of partial irradiation is increasing and the tendencies of protection quantities caused under those irradiation conditions are different. The code system has been developed and effective dose and organ absorbed doses have been calculated in the case of horizontal narrow photon beam irradiated from various directions at three representative body sections, 40, 50 and 60 cm originating from the top of the head. This work covers 24 beam directions, each 15 degrees angle ranging from 0 degrees to 345 degrees, three energy levels, 45 keV, 90 keV and 1.25 MeV, and three beam diameters of 1, 2 and 4 cm. These results show that the beam injected from diagonally front or other specific direction causes peak dose in the case of partial irradiation.
Dual-resolution dose assessments for proton beamlet using MCNPX 2.6.0
NASA Astrophysics Data System (ADS)
Chao, T. C.; Wei, S. C.; Wu, S. W.; Tung, C. J.; Tu, S. J.; Cheng, H. W.; Lee, C. C.
2015-11-01
The purpose of this study is to access proton dose distribution in dual resolution phantoms using MCNPX 2.6.0. The dual resolution phantom uses higher resolution in Bragg peak, area near large dose gradient, or heterogeneous interface and lower resolution in the rest. MCNPX 2.6.0 was installed in Ubuntu 10.04 with MPI for parallel computing. FMesh1 tallies were utilized to record the energy deposition which is a special designed tally for voxel phantoms that converts dose deposition from fluence. 60 and 120 MeV narrow proton beam were incident into Coarse, Dual and Fine resolution phantoms with pure water, water-bone-water and water-air-water setups. The doses in coarse resolution phantoms are underestimated owing to partial volume effect. The dose distributions in dual or high resolution phantoms agreed well with each other and dual resolution phantoms were at least 10 times more efficient than fine resolution one. Because the secondary particle range is much longer in air than in water, the dose of low density region may be under-estimated if the resolution or calculation grid is not small enough.
Donck, Jan; Gonzalez-Tabares, Lourdes; Chanliau, Jacques; Martin, Heike; Stamatelou, Kyriaki; Manamley, Nick; Farouk, Mourad; Addison, Janet
2014-11-01
There is scant real-world information on switching treatment for anemia associated with chronic kidney disease (CKD) from methoxy polyethylene glycol-epoetin beta (PEG-Epo) to darbepoetin alfa (DA). TRANSFORM was a multi-center, observational study designed to describe the time course of hemoglobin (Hb) concentration (primary outcome measure) and other parameters of clinical management of anemia in European hemodialysis patients in clinical practice before and after a switch from PEG-Epo to DA. Eligible subjects were adult patients with CKD dialyzed at European dialysis centers for ≥26 weeks and treated with PEG-Epo for ≥14 weeks immediately prior to being switched to DA and no earlier than January 2011. Erythropoiesis-stimulating agent doses and Hb values were recorded for the 14-week pre-switch and 26-week post-switch periods. Of the 1,027 eligible patients enrolled at 42 hemodialysis centers in 7 European countries, 785 were included in analyses. Mean (95% confidence interval [CI]) Hb was generally stable: 11.19 (11.11, 11.26), 11.48 (11.40, 11.57), and 11.29 (11.20, 11.37) g/dL at month -1 pre-switch and months 3 and 6 post-switch, respectively. The geometric mean (95% CI) PEG-Epo dose at month -1 was 27.4 (26.0, 28.8) µg/week; DA dose was 29.4 (27.9, 30.9), 23.3 (21.9, 24.9), and 25.6 (24.1, 27.1) µg/week at months 1, 4, and 6, respectively. The geometric mean (95% CI) dose ratio at switching was 1.06 (1.01, 1.11). When stratifying by dose-ratio categories <0.8, 0.8-1.2, and >1.2 at switching, mean DA dose and Hb converged within narrow ranges by month 6 post-switch: 23.9-27.0 µg/week and 11.1-11.5 g/dL, respectively. Hb excursions <10 g/dL were less frequent post-switch versus pre-switch. Mean Hb values remained within a narrow range following switching from PEG-Epo to DA in this population of hemodialysis patients. Time trends of mean Hb and DA dose indicate that physicians titrated DA doses post-switch, to attain Hb concentrations comparable to those attained pre-switch with PEG-Epo.
Nagappan, Raja
2012-09-01
To evaluate aqueous and ethanol extract of Cassia didymobotrya leaves against immature stages of Culex quinquefasciatus. The mortality rate of immature mosquitoes was tested in wide and narrow range concentration of the plant extract based on WHO standard protocol. The wide range concentration tested in the present study was 10 000, 1 000, 100, 10 and 1 mg/L and narrow range concentration was 50, 100, 150, 200 and 250 mg/L. 2nd instar larvae exposed to 100 mg/L and above concentration of ethanol extract showed 100% mortality. Remaining stages such as 3rd, 4th and pupa, 100% mortality was observed at 1 000 mg/L and above concentration after 24 h exposure period. In aqueous extract all the stages 100% mortality was recorded at 1 000 mg/L and above concentration. In narrow range concentration 2nd instar larvae 100% mortality was observed at 150 mg/L and above concentration of ethanol extract. The remaining stages 100% mortality was recorded at 250 mg/L. In aqueous extract all the tested immature stages 100% mortality was observed at 250 mg/L concentration after 24 h exposure period. The results clearly indicate that the rate of mortality was based dose of the plant extract and stage of the mosquitoes. From this study it is confirmed and concluded that Cassia didymobotrya is having active principle which is responsible for controlling Culex quinquefasciatus. The isolation of bioactive molecules and development of simple formulation technique is important for large scale implementation.
Dopamine modulates episodic memory persistence in old age
Chowdhury, Rumana; Guitart-Masip, Marc; Bunzeck, Nico; Dolan, Raymond J; Düzel, Emrah
2013-01-01
Activation of the hippocampus is required in order to encode memories for new events (or episodes). Observations from animal studies suggest that for these memories to persist beyond 4 to 6 hours, a release of dopamine generated by strong hippocampal activation is needed. This predicts that dopaminergic enhancement should improve human episodic memory persistence also for events encoded with weak hippocampal activation. Here, using pharmacological fMRI in an elderly population where there is a loss of dopamine neurons as part of normal aging, we show this very effect. The dopamine precursor levodopa led to a dose-dependent (inverted U-shape) persistent episodic memory benefit for images of scenes when tested after 6 hours, independent of whether encoding-related hippocampal fMRI activity was weak or strong (U-shaped dose-response relationship). This lasting improvement even for weakly encoded events supports a role for dopamine in human episodic memory consolidation albeit operating within a narrow dose range. PMID:23055489
LaSala, Anthony; Bower, Bruce; Windemuth, Andreas; White, C. Michael; Kocherla, Mohan; Seip, Richard; Duconge, Jorge; Ruaño, Gualberto
2013-01-01
Warfarin is a well established oral anticoagulant for the treatment of thromboembolic disorders. Warfarin therapy is complicated by a narrow therapeutic index and marked inter-individual dose variability with therapeutic doses ranging from 1 mg to 10 mg/day.1 Recently genetic variation and resultant drug metabolizing polymorphisms have been found to contribute to warfarin dose variability with resultant hemorrhagic or thromboembolic complications. Cytochrome P450 2C9 alters the rate of warfarin metabolism and clearance. A second enzyme, vitamin K epoxide reductase comple (VKOR) binds and reduces vitamin K which is necessary for activation of clotting Factors II, VII, IX and X. The VKORC1 gene encodes for vitamin K epoxide reductase complex subunit 1, a key component of VKOR. The combination of physiologic factors (30%), CYP2C9 variations (20%) and VKORC1 variants (25%) accounts for approximately 75% of warfarin dose variability. This illustrative case report demonstrates the clinical importance of this new information. Clinicians need to incorporate these new genomic findings into appropriate management of warfarin dose anticoagulation. PMID:18763667
Poppinga, D; Meyners, J; Delfs, B; Muru, A; Harder, D; Poppe, B; Looe, H K
2015-12-21
This study aims at the experimental determination of the detector-specific 1D lateral dose response function K(x) and of its associated rotational symmetric counterpart K(r) for a set of high-resolution detectors presently used in narrow-beam photon dosimetry. A combination of slit-beam, radiochromic film, and deconvolution techniques served to accomplish this task for four detectors with diameters of their sensitive volumes ranging from 1 to 2.2 mm. The particular aim of the experiment was to examine the existence of significant negative portions of some of these response functions predicted by a recent Monte-Carlo-simulation (Looe et al 2015 Phys. Med. Biol. 60 6585-607). In a 6 MV photon slit beam formed by the Siemens Artiste collimation system and a 0.5 mm wide slit between 10 cm thick lead blocks serving as the tertiary collimator, the true cross-beam dose profile D(x) at 3 cm depth in a large water phantom was measured with radiochromic film EBT3, and the detector-affected cross-beam signal profiles M(x) were recorded with a silicon diode, a synthetic diamond detector, a miniaturized scintillation detector, and a small ionization chamber. For each detector, the deconvolution of the convolution integral M(x) = K(x) ∗ D(x) served to obtain its specific 1D lateral dose response function K(x), and K(r) was calculated from it. Fourier transformations and back transformations were performed using function approximations by weighted sums of Gaussian functions and their analytical transformation. The 1D lateral dose response functions K(x) of the four types of detectors and their associated rotational symmetric counterparts K(r) were obtained. Significant negative curve portions of K(x) and K(r) were observed in the case of the silicon diode and the diamond detector, confirming the Monte-Carlo-based prediction (Looe et al 2015 Phys. Med. Biol. 60 6585-607). They are typical for the perturbation of the secondary electron field by a detector with enhanced electron density compared with the surrounding water. In the cases of the scintillation detector and the small ionization chamber, the negative curve portions of K(x) practically vanish. It is planned to use the measured functions K(x) and K(r) to deconvolve clinical narrow-beam signal profiles and to correct the output factor values obtained with various high-resolution detectors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perisinakis, Kostas; Seimenis, Ioannis; Tzedakis, Antonis
Purpose: To determine patient-specific absorbed peak doses to skin, eye lens, brain parenchyma, and cranial red bone marrow (RBM) of adult individuals subjected to low-dose brain perfusion CT studies on a 256-slice CT scanner, and investigate the effect of patient head size/shape, head position during the examination and bowtie filter used on peak tissue doses. Methods: The peak doses to eye lens, skin, brain, and RBM were measured in 106 individual-specific adult head phantoms subjected to the standard low-dose brain perfusion CT on a 256-slice CT scanner using a novel Monte Carlo simulation software dedicated for patient CT dosimetry. Peakmore » tissue doses were compared to corresponding thresholds for induction of cataract, erythema, cerebrovascular disease, and depression of hematopoiesis, respectively. The effects of patient head size/shape, head position during acquisition and bowtie filter used on resulting peak patient tissue doses were investigated. The effect of eye-lens position in the scanned head region was also investigated. The effect of miscentering and use of narrow bowtie filter on image quality was assessed. Results: The mean peak doses to eye lens, skin, brain, and RBM were found to be 124, 120, 95, and 163 mGy, respectively. The effect of patient head size and shape on peak tissue doses was found to be minimal since maximum differences were less than 7%. Patient head miscentering and bowtie filter selection were found to have a considerable effect on peak tissue doses. The peak eye-lens dose saving achieved by elevating head by 4 cm with respect to isocenter and using a narrow wedge filter was found to approach 50%. When the eye lies outside of the primarily irradiated head region, the dose to eye lens was found to drop to less than 20% of the corresponding dose measured when the eye lens was located in the middle of the x-ray beam. Positioning head phantom off-isocenter by 4 cm and employing a narrow wedge filter results in a moderate reduction of signal-to-noise ratio mainly to the peripheral region of the phantom. Conclusions: Despite typical peak doses to skin, eye lens, brain, and RBM from the standard low-dose brain perfusion 256-slice CT protocol are well below the corresponding thresholds for the induction of erythema, cataract, cerebrovascular disease, and depression of hematopoiesis, respectively, every effort should be made toward optimization of the procedure and minimization of dose received by these tissues. The current study provides evidence that the use of the narrower bowtie filter available may considerably reduce peak absorbed dose to all above radiosensitive tissues with minimal deterioration in image quality. Considerable reduction in peak eye-lens dose may also be achieved by positioning patient head center a few centimeters above isocenter during the exposure.« less
Stepanenko, Valeriy F; Hoshi, Masaharu; Dubasov, Yuriy V; Sakaguchi, Aya; Yamamoto, Masayoshi; Orlov, Mark Y; Bailiff, Ian K; Ivannikov, Alexander I; Skvortsov, Valeriy G; Iaskova, Elena K; Kryukova, Irina G; Zhumadilov, Kassym S; Endo, Satoru; Tanaka, Kenichi; Apsalikov, Kazbek N; Gusev, Boris I
2006-02-01
Spatial distributions of soil contamination by 137Cs (89 sampling points) and 239+240Pu (76 points) near and within Dolon village were analyzed. An essential exponential decrease of contamination was found in Dolon village: the distance of a half reduction in contamination is about 0.87-1.25 km (in a northwest-southeast direction from the supposed centerline of the radioactive trace). This fact is in agreement with the available exposure rate measurements near Dolon (September 1949 archive data): on the basis of a few measurements the pattern of the trace was estimated to comprise a narrow 2 km corridor of maximum exposure rate. To compare computed external doses in air with local dose estimates by retrospective luminescence dosimetry (RLD) the gradient of radioactive soil contamination within the village was accounted for. The computed dose associated with the central axis of the trace was found to be equal to 2260 mGy (calculations based on archive exposure rate data). Local doses near the RLD sampling points (southeast of the village) were calculated to be in the range 466-780 mGy (averaged value: 645+/-70 mGy), which is comparable with RLD data (averaged value 460+/-92 mGy with range 380-618 mGy). A comparison of the computed mean dose in the settlement with dose estimates by ESR tooth enamel dosimetry makes it possible to estimate the "upper level" of the "shielding and behavior" factor in dose reduction for inhabitants of Dolon village which was found to be 0.28+/-0.068.
Grover, Anita; Benet, Leslie Z.
2013-01-01
Intermittent drug dosing intervals are usually initially guided by the terminal pharmacokinetic half life and are dependent on drug formulation. For chronic multiple dosing and for extended release dosage forms, the terminal half life often does not predict the plasma drug accumulation or fluctuation observed. We define and advance applications for the operational multiple dosing half lives for drug accumulation and fluctuation after multiple oral dosing at steady-state. Using Monte Carlo simulation, our results predict a way to maximize the operational multiple dosing half lives relative to the terminal half life by using a first-order absorption rate constant close to the terminal elimination rate constant in the design of extended release dosage forms. In this way, drugs that may be eliminated early in the development pipeline due to a relatively short half life can be formulated to be dosed at intervals three times the terminal half life, maximizing compliance, while maintaining tight plasma concentration accumulation and fluctuation ranges. We also present situations in which the operational multiple dosing half lives will be especially relevant in the determination of dosing intervals, including for drugs that follow a direct PKPD model and have a narrow therapeutic index, as the rate of concentration decrease after chronic multiple dosing (that is not the terminal half life) can be determined via simulation. These principles are illustrated with case studies on valproic acid, diazepam, and anti-hypertensives. PMID:21499748
SU-F-I-71: Fetal Protection During Fluoroscopy: To Shield Or Not to Shield?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joshi, S; Vanderhoek, M
Purpose: Lead aprons are routinely used to shield the fetus from radiation during fluoroscopically guided interventions (FGI) involving pregnant patients. When placed in the primary beam, lead aprons often reduce image quality and increase fluoroscopic radiation output, which can adversely affect fetal dose. The purpose of this work is to identify an effective and practical method to reduce fetal dose without affecting image quality. Methods: A pregnant patient equivalent abdominal phantom is set on the table along with an image quality test object (CIRS model 903) representing patient anatomy of interest. An ion chamber is positioned at the x-ray beammore » entrance to the phantom, which is used to estimate the relative fetal dose. For three protective methods, image quality and fetal dose measurements are compared to baseline (no protection):1. Lead apron shielding the entire abdomen; 2. Lead apron shielding part of the abdomen, including the fetus; 3. Narrow collimation such that fetus is excluded from the primary beam. Results: With lead shielding the entire abdomen, the dose is reduced by 80% relative to baseline along with a drastic deterioration of image quality. With lead shielding only the fetus, the dose is reduced by 65% along with complete preservation of image quality, since the image quality test object is not shielded. However, narrow collimation results in 90% dose reduction and a slight improvement of image quality relative to baseline. Conclusion: The use of narrow collimation to protect the fetus during FGI is a simple and highly effective method that simultaneously reduces fetal dose and maintains sufficient image quality. Lead aprons are not as effective at fetal dose reduction, and if placed improperly, they can severely degrade image quality. Future work aims to investigate a wider variety of fluoroscopy systems to confirm these results across many different system geometries.« less
Total ionizing dose effect in an input/output device for flash memory
NASA Astrophysics Data System (ADS)
Liu, Zhang-Li; Hu, Zhi-Yuan; Zhang, Zheng-Xuan; Shao, Hua; Chen, Ming; Bi, Da-Wei; Ning, Bing-Xu; Zou, Shi-Chang
2011-12-01
Input/output devices for flash memory are exposed to gamma ray irradiation. Total ionizing dose has been shown great influence on characteristic degradation of transistors with different sizes. In this paper, we observed a larger increase of off-state leakage in the short channel device than in long one. However, a larger threshold voltage shift is observed for the narrow width device than for the wide one, which is well known as the radiation induced narrow channel effect. The radiation induced charge in the shallow trench isolation oxide influences the electric field of the narrow channel device. Also, the drain bias dependence of the off-state leakage after irradiation is observed, which is called the radiation enhanced drain induced barrier lowing effect. Finally, we found that substrate bias voltage can suppress the off-state leakage, while leading to more obvious hump effect.
Effect of common building materials in narrow shaped X-ray fields transmission
NASA Astrophysics Data System (ADS)
Vlachos, I.; Tsantilas, X.; Fountos, G.; Delis, H.; Kandarakis, I.; Panayiotakis, G.
2015-09-01
Diagnostic and interventional radiology, are an essential part of present day medical practice. Advances in X-ray imaging technology, together with developments in digital imaging have had a significant impact on the practice of radiology. This includes improvement in image quality, reduction in dose and a broader range of available applications resulting to better patient diagnosis and treatment. X-rays have the potential for damaging healthy cells and tissues, therefore all medical procedures employing X-ray equipment must be carefully managed. In all facilities and for all equipment types, procedures must be in place in order to ensure that exposures to patients, staff and the public are kept as low as reasonably achievable. Commonly used construction materials such as, ceramic tiles and plasterboards can provide a certain degree of protection against X-radiation. In this study, the secondary radiation transmission through common building materials is investigated, in the case of narrow shaped X-ray fields. Double plasterboard and double reinforced in thickness ceramic tile provided better radiation protection results.
Choi, Kyu-Won; Kim, Ki-Ho
2009-01-01
Background Determination of the minimal erythema dose (MED) is important for developing a phototherapy protocol and to diagnosis photosensitivity disorders. But obtaining a precise and reproducible MED is quite difficult because a phototest for erythema is based on subjective assessment. Objective The objective of our study was to compare the gross interpretation of a phototest and the objective measurement using a spectrophotometer for determining the parameters of cutaneous narrow-band UVB (NBUVB) therapy. Methods A total of 14 psoriasis and 10 vitiligo patients who receiving NBUVB phototherapy with skin types III and IV were selected for this study. To perform phototesting, ten sites on the skin of the back were vertically exposed to a series of 10 NBUVB doses among 14 doses between 340 and 1,400 mJ/cm2. We interpreted the gross findings of erythema and measured the L*a*b* values with using a spectrophotometer at each phototest spot and at the control skin. Also, we evaluate the relationship between the gross presentation and the spectrophotometric analysis by delta E for the assessment of the minimal perceptible erythema (MPE) and MED. Results For all the subjects, the MEDs were measured in the 490~1,000 mJ/cm2 range. The average of the colorimetric values for the control skin were L*: 64.8, a*: 7.9 and b*: 19.8. Among them, the L* value and MED value were shown to be inversely correlated, and as the L* value was decreased, the MED was increased. For the MPE, the delta E, which was the color difference of the normal skin and the phototest area, was within the range of 1.5~3.0 in 17 of the 21 patients, and 4 patients were within the range of 1.0~1.5. For the MED, among the 21 patients, the delta E of 17 patients was within the range of 3.0~6.0, and 4 patients were within the range of 6.0~12.0. Conclusion A spectrophotometer enables UV erythema to be assessed objectively and quantitatively, and this can compensate for the disadvantages of subjective gross interpretation when determining the MED. Delta E is a good novel and objective indicator for determining the MPE and MED. So, a spectrophotometer is a very useful instrument for developing a phototherapy protocol for psoriasis and other dermatoses and for making the diagnosis of photosensitivity disorders. PMID:20523771
Choi, Kyu-Won; Kim, Ki-Ho; Kim, Young-Hun
2009-05-01
Determination of the minimal erythema dose (MED) is important for developing a phototherapy protocol and to diagnosis photosensitivity disorders. But obtaining a precise and reproducible MED is quite difficult because a phototest for erythema is based on subjective assessment. The objective of our study was to compare the gross interpretation of a phototest and the objective measurement using a spectrophotometer for determining the parameters of cutaneous narrow-band UVB (NBUVB) therapy. A total of 14 psoriasis and 10 vitiligo patients who receiving NBUVB phototherapy with skin types III and IV were selected for this study. To perform phototesting, ten sites on the skin of the back were vertically exposed to a series of 10 NBUVB doses among 14 doses between 340 and 1,400 mJ/cm(2). We interpreted the gross findings of erythema and measured the L*a*b* values with using a spectrophotometer at each phototest spot and at the control skin. Also, we evaluate the relationship between the gross presentation and the spectrophotometric analysis by delta E for the assessment of the minimal perceptible erythema (MPE) and MED. For all the subjects, the MEDs were measured in the 490~1,000 mJ/cm(2) range. The average of the colorimetric values for the control skin were L*: 64.8, a*: 7.9 and b*: 19.8. Among them, the L* value and MED value were shown to be inversely correlated, and as the L* value was decreased, the MED was increased. For the MPE, the delta E, which was the color difference of the normal skin and the phototest area, was within the range of 1.5~3.0 in 17 of the 21 patients, and 4 patients were within the range of 1.0~1.5. For the MED, among the 21 patients, the delta E of 17 patients was within the range of 3.0~6.0, and 4 patients were within the range of 6.0~12.0. A spectrophotometer enables UV erythema to be assessed objectively and quantitatively, and this can compensate for the disadvantages of subjective gross interpretation when determining the MED. Delta E is a good novel and objective indicator for determining the MPE and MED. So, a spectrophotometer is a very useful instrument for developing a phototherapy protocol for psoriasis and other dermatoses and for making the diagnosis of photosensitivity disorders.
Optimisation of environmental remediation: how to select and use the reference levels.
Balonov, M; Chipiga, L; Kiselev, S; Sneve, M; Yankovich, T; Proehl, G
2018-06-01
A number of past industrial activities and accidents have resulted in the radioactive contamination of large areas at many sites around the world, giving rise to a need for remediation. According to the International Commission on Radiological Protection (ICRP) and International Atomic Energy Agency (IAEA), such situations should be managed as existing exposure situations (ExESs). Control of exposure to the public in ExESs is based on the application of appropriate reference levels (RLs) for residual doses. The implementation of this potentially fruitful concept for the optimisation of remediation in various regions is hampered by a lack of practical experience and relevant guidance. This paper suggests a generic methodology for the selection of numeric values of relevant RLs both in terms of residual annual effective dose and derived RLs (DRLs) based on an appropriate dose assessment. The value for an RL should be selected in the range of the annual residual effective dose of 1-20 mSv, depending on the prevailing circumstances for the exposure under consideration. Within this range, RL values should be chosen by the following assessment steps: (a) assessment of the projected dose, i.e. the dose to a representative person without remedial actions by means of a realistic model as opposed to a conservative model; (b) modelling of the residual dose to a representative person following application of feasible remedial actions; and (c) selection of an RL value between the projected and residual doses, taking account of the prevailing social and economic conditions. This paper also contains some recommendations for practical implementation of the selected RLs for the optimisation of public protection. The suggested methodology used for the selection of RLs (in terms of dose) and the calculation of DRLs (in terms of activity concentration in food, ambient dose rate, etc) has been illustrated by a retrospective analysis of post-Chernobyl monitoring and modelling data from the Bryansk region, Russia, 2001. From this example, it follows that analysis of real data leads to the selection of an RL from a relatively narrow annual dose range (in this case, about 2-3 mSv), from which relevant DRLs can be calculated and directly used for optimisation of the remediation programme.
Mori, Yutaka; Taniguchi, Yukiko; Miyazaki, Shigeru; Yokoyama, Junichi; Utsunomiya, Kazunori
2013-03-01
In an earlier continuous glucose monitoring (CGM)-based study, we reported that sitagliptin not only reduced 24-h mean glucose levels but also suppressed postprandial glucose increases, thus reducing the range of glycemic fluctuations in type 2 diabetes patients. In this study, we investigated whether sitagliptin might provide similar benefits in type 2 diabetes patients receiving insulin therapy by using CGM. The study included a total of 13 type 2 diabetes patients in whom stable glycemic control had been achieved after admission for glycemic control. Insulin regimens used included long-acting insulin preparations once daily in four patients and biphasic insulin preparations twice daily in nine, with the daily insulin dose being 19.0±12.7 U. During the CGM-based study, the patients were given insulin therapy alone on Days 1 and 2 and were given sitagliptin 50 mg/day as add-on treatment on Days 3-6, with their daily insulin doses maintained. The add-on treatment with sitagliptin led to significant decreases in 24-h mean glucose levels and SDs of 288 glucose levels measured by CGM for 24 h, as well as in the indices for magnitude of glucose variability and proportion of time in hyperglycemia, compared with insulin therapy alone (P<0.01), whereas there was no significant change seen in regard to the proportion of time in hypoglycemia with or without add-on treatment with sitagliptin. This CGM-based study clearly demonstrated that insulin therapy alone, whether with long-acting or biphasic insulin preparations, does not provide adequate glycemic control in type 2 diabetes patients. In contrast, add-on sitagliptin was shown to narrow the range of 24-h glucose fluctuations in these patients, suggesting that add-on treatment with sitagliptin is effective for postprandial glucose control in type 2 diabetes patients receiving insulin therapy.
Figueroa, Isabel; Leipold, Doug; Leong, Steve; Zheng, Bing; Triguero-Carrasco, Montserrat; Fourie-O'Donohue, Aimee; Kozak, Katherine R; Xu, Keyang; Schutten, Melissa; Wang, Hong; Polson, Andrew G; Kamath, Amrita V
2018-05-14
For antibody-drug conjugates (ADCs) that carry a cytotoxic drug, doses that can be administered in preclinical studies are typically limited by tolerability, leading to a narrow dose range that can be tested. For molecules with non-linear pharmacokinetics (PK), this limited dose range may be insufficient to fully characterize the PK of the ADC and limits translation to humans. Mathematical PK models are frequently used for molecule selection during preclinical drug development and for translational predictions to guide clinical study design. Here, we present a practical approach that uses limited PK and receptor occupancy (RO) data of the corresponding unconjugated antibody to predict ADC PK when conjugation does not alter the non-specific clearance or the antibody-target interaction. We used a 2-compartment model incorporating non-specific and specific (target mediated) clearances, where the latter is a function of RO, to describe the PK of anti-CD33 ADC with dose-limiting neutropenia in cynomolgus monkeys. We tested our model by comparing PK predictions based on the unconjugated antibody to observed ADC PK data that was not utilized for model development. Prospective prediction of human PK was performed by incorporating in vitro binding affinity differences between species for varying levels of CD33 target expression. Additionally, this approach was used to predict human PK of other previously tested anti-CD33 molecules with published clinical data. The findings showed that, for a cytotoxic ADC with non-linear PK and limited preclinical PK data, incorporating RO in the PK model and using data from the corresponding unconjugated antibody at higher doses allowed the identification of parameters to characterize monkey PK and enabled human PK predictions.
Leyden, James J; Sniukiene, Vilma; Berk, David R; Kaoukhov, Alexandre
2018-03-01
There is a need for new oral antibiotics for acne with improved safety profiles and targeted antibacterial spectra. Sarecycline is a novel, tetracycline-class antibiotic specifically designed for acne, offering a narrow spectrum of activity compared with currently available tetracyclines, including less activity against enteric Gram-negative bacteria. This phase 2 study evaluated the efficacy and safety of three doses of sarecycline for moderate to severe facial acne vulgaris. In this multicenter, double-blind, placebo-controlled study, patients aged 12 to 45 years were randomized to once-daily sarecycline 0.75 mg/kg, 1.5 mg/kg, 3.0 mg/kg, or placebo. Efficacy analyses included change from baseline in inflammatory and noninflammatory lesion counts at week 12, with between-group comparisons using analysis of covariance. Safety assessments included adverse events (AEs), clinical laboratories, vital signs, electrocardiograms, and physical examinations. Overall, 285 randomized patients received at least one dose of study drug. At week 12, sarecycline 1.5 mg/kg and 3.0 mg/kg groups demonstrated significantly reduced inflammatory lesions from baseline (52.7% and 51.8%, respectively) versus placebo (38.3%; P=0.02 and P=0.03, respectively). Sarecycline was safe and well tolerated, with similar gastrointestinal AE rates in sarecycline and placebo groups. Vertigo and photosensitivity AEs occurred in less than 1% of patients when pooling sarecycline groups; no vulvovaginal candidiasis AEs occurred. Discontinuation rates due to AEs were low. No serious AEs occurred. Once-daily sarecycline 1.5 mg/kg significantly reduced inflammatory lesions versus placebo and was safe and well tolerated with low rates of AEs, including gastrointestinal AEs. Sarecycline 3.0 mg/kg did not result in additional efficacy versus 1.5 mg/kg. Sarecycline may represent a novel, once-daily treatment for patients with moderate to severe acne. It offers a narrow antibacterial spectrum relative to other tetracycline options, which may lead to less selective pressure on enteric Gram-negative bacteria, resulting in less disruption of commensal organisms and less potential for antibiotic resistance.
J Drugs Dermatol. 2018;17(3):333-338.
.Myristicin and phenytoin toxicity in an infant
Sivathanu, Shobhana; Sampath, Sowmya; David, Henry Suresh; Rajavelu, Kulandai Kasthuri
2014-01-01
A developmentally normal infant presented with repeated episodes of afebrile status epilepticus following nutmeg ingestion. He had developed two episodes of afebrile status epilepticus and had received different treatments earlier, but the details of treatment were not available. On admission, he redeveloped convulsions and loading doses of phenytoin, phenobarbitone and midazolam were administered. However, seizures persisted and extrapyramidal movements, nystagmus and visual dysfunction were noted. Iatrogenic phenytoin toxicity was considered and confirmed by drug levels. His symptoms completely disappeared after discontinuation of phenytoin therapy. The initial seizures were attributed to myristicin, an active component of nutmeg, because of the temporal association. However, the subsequent seizures were due to phenytoin toxicity caused by administration of multiple loading doses. This case highlights that nutmeg, a spice, can cause serious toxic effects like status epilepticus. Furthermore, treatment of status epilepticus with phenytoin can cause iatrogenic seizures due to its narrow therapeutic range. PMID:24903724
A study on the suitability of the PTW microDiamond detector for kilovoltage x-ray beam dosimetry.
Damodar, Joshita; Odgers, David; Pope, Dane; Hill, Robin
2018-05-01
Kilovoltage x-ray beams are widely used in treating skin cancers and in biological irradiators. In this work, we have evaluated four dosimeters (ionization chambers and solid state detectors) in their suitability for relative dosimetry of kilovoltage x-ray beams in the energy range of 50 - 280kVp. The solid state detectors, which have not been investigated with low energy x-rays, were the PTW 60019 microDiamond synthetic diamond detector and the PTW 60012 diode. The two ionization chambers used were the PTW Advanced Markus parallel plate chamber and the PTW PinPoint small volume chamber. For each of the dosimeters, percentage depth doses were measured in water over the full range of x-ray beams and for field sizes ranging from 2cm diameter to 12 × 12cm. In addition, depth doses were measured for a narrow aperture (7mm diameter) using the PTW microDiamond detector. For comparison, the measured data was compared with Monte Carlo calculated doses using the EGSnrc Monte Carlo package. The depth dose results indicate that the Advanced Markus parallel plate and PinPoint ionization chambers were suitable for depth dose measurements in the beam quality range with an uncertainty of less than 3%, including in the regions closer to the surface of the water as compared with Monte Carlo depth dose data for all six energy beams. The response of the PTW Diode E detector was accurate to within 4% for all field sizes in the energy range of 50-125kVp but showed larger variations for higher energies of up to 12% with the 12 × 12cm field size. In comparison, the microDiamond detector had good agreement over all energies for both smaller and larger field sizes generally within 1% as compared to the Advanced Markus chamber field and Monte Carlo calculations. The only exceptions were in measuring the dose at the surface of the water phantom where larger differences were found. For the 7mm diameter field, the agreement between the microDiamond detector and Monte Carlo calculations was good being better than 1% except at the surface. Based on these results, the PTW microDiamond detector has shown to be a suitable detector for relative dosimetry of low energy x-ray beams over a wide range of x-ray beam energies. Copyright © 2018 Elsevier Ltd. All rights reserved.
Current clinical use of reteplase for thrombolysis. A pharmacokinetic-pharmacodynamic perspective.
Martin, U; Kaufmann, B; Neugebauer, G
1999-04-01
Clinical evaluation of a new thrombolytic agent should start with a dose that provides adequate efficacy and has an acceptably low bleeding risk; this results in a narrow therapeutic window at the upper end of the dose-response curve. Angiographic patency of the infarct-related artery is still the clinical surrogate end-point for mortality in phase II dose-ranging studies. There is experimental and clinical evidence that the area under the concentration-time curve (AUC) for plasminogenolytic activity of a thrombolytic agent is positively correlated with patency of the infarct-related artery. Dose-ranging studies of the novel recombinant plasminogen activator reteplase in healthy volunteers enabled computation of a linear regression curve by which a clinical starting dose could be calculated for an adapted target AUC that would be clinically effective. Pharmacokinetic analysis also revealed that the half-life of reteplase is 4 times longer than that of the reference thrombolytic alteplase, thus allowing bolus injection. The suggested single bolus starting dose of 10U was supported by results from studies in a canine model of coronary thrombolysis. The feedback of insufficiently high patency rates compared with the increased efficacy of front-loaded and accelerated alteplase demanded optimisation strategies for reteplase. Animal experiments suggested that a double bolus regimen of reteplase would be preferable to doubling the single bolus dose. Pharmacokinetic modelling suggested a time interval of 30 min between the 2 bolus injections. Selection of the tested double bolus regimens was conservative and empirical. First, the previously tested single bolus of 15U was divided to 10 + 5U; secondly, the second bolus dose was increased to 10U. This strategy proved to be successful. The current dosage recommendation for reteplase is a double bolus intravenous injection of 10 + 10U, each over 2 min, 30 min apart. This produces a reduction in mortality in patients with acute myocardial infarction that is equivalent to that produced by front-loaded and accelerated infusion of alteplase.
Are bioequivalence studies of levothyroxine sodium formulations in euthyroid volunteers reliable?
Blakesley, Vicky; Awni, Walid; Locke, Charles; Ludden, Thomas; Granneman, G Richard; Braverman, Lewis E
2004-03-01
Levothyroxine (LT4) has a narrow therapeutic index. Consequently, precise standards for assessing the bioequivalence of different LT4 products are vital. We examined the methodology that the Food and Drug Administration (FDA) recommends for comparing the bioavailability of LT4 products, as well as three modifications to correct for endogenous, thyroxine (T4) levels, to determine if the methodology could distinguish LT4 products that differ by 12.5%, 25%, or 33%. With no baseline correction for the endogenous T4 pool, differences in administered LT4 doses that differed by 25%-33% could not be detected (450 microg and 400 microg doses versus 600 microg dose, respectively). The three mathematical correction methods could distinguish the doses that differed by 25% and 33%. None of the correction methods could distinguish dosage strengths that differed by 12.5% (450 microg versus 400 microg). Dose differences within this range are known to result in clinically relevant differences in safety and effectiveness. Methods of analysis of bioequivalence data that do not consider endogenous T4 concentrations confound accurate quantitation and interpretation of LT4 bioavailability. As a result, products inappropriately deemed bioequivalent may put patients at risk for iatrogenic hyperthyroidism or hypothyroidism. More precise methods for defining bioequivalence are required in order to ensure that LT4 products accepted as bioequivalent will perform equivalently in patients without the need for further monitoring and retitration of their dose.
NASA Astrophysics Data System (ADS)
Adamus-Górka, Magdalena; Mavroidis, Panayiotis; Brahme, Anders; Lind, Bengt K.
2008-11-01
Radiobiological models for estimating normal tissue complication probability (NTCP) are increasingly used in order to quantify or optimize the clinical outcome of radiation therapy. A good NTCP model should fulfill at least the following two requirements: (a) it should predict the sigmoid shape of the corresponding dose-response curve and (b) it should accurately describe the probability of a specified response for arbitrary non-uniform dose delivery for a given endpoint as accurately as possible, i.e. predict the volume dependence. In recent studies of the volume effect of a rat spinal cord after irradiation with narrow and broad proton beams the authors claim that none of the existing NTCP models is able to describe their results. Published experimental data have been used here to try to quantify the change in the effective dose (D50) causing 50% response for different field sizes. The present study was initiated to describe the induction of white matter necrosis in a rat spinal cord after irradiation with narrow proton beams in terms of the mean dose to the effective volume of the functional subunit (FSU). The physically delivered dose distribution was convolved with a function describing the effective size or, more accurately, the sensitivity distribution of the FSU to obtain the effective mean dose deposited in it. This procedure allows the determination of the mean D50 value of the FSUs of a certain size which is of interest for example if the cell nucleus of the oligodendrocyte is the sensitive target. Using the least-squares method to compare the effective doses for different sizes of the functional subunits with the experimental data the best fit was obtained with a length of about 9 mm. For the non-uniform dose distributions an effective FSU length of 8 mm gave the optimal fit with the probit dose-response model. The method could also be used to interpret the so-called bath and shower experiments where the heterogeneous dose delivery was used in the convolution process. The assumption of an effective FSU size is consistent with most of the effects seen when different portions of the rat spinal cord are irradiated to different doses. The effective FSU length from these experiments is about 8.5 ± 0.5 mm. This length could be interpreted as an effective size of the functional subunits in a rat spinal cord, where multiple myelin sheaths are connected by a single oligodendrocyte and repair is limited by the range of oligodendrocyte progenitor cell diffusion. It was even possible to suggest a more likely than uniform effective FSU sensitivity distribution from the experimental data.
Severgnini, Mara; de Denaro, Mario; Bortul, Marina; Vidali, Cristiana; Beorchia, Aulo
2014-01-08
Intraoperative electron radiation therapy (IOERT) cannot usually benefit, as conventional external radiotherapy, from software systems of treatment planning based on computed tomography and from common dose verify procedures. For this reason, in vivo film dosimetry (IVFD) proves to be an effective methodology to evaluate the actual radiation dose delivered to the target. A practical method for IVFD during breast IOERT was carried out to improve information on the dose actually delivered to the tumor target and on the alignment of the shielding disk with respect to the electron beam. Two EBT3 GAFCHROMIC films have been positioned on the two sides of the shielding disk in order to obtain the dose maps at the target and beyond the disk. Moreover the postprocessing analysis of the dose distribution measured on the films provides a quantitative estimate of the misalignment between the collimator and the disk. EBT3 radiochromic films have been demonstrated to be suitable dosimeters for IVD due to their linear dose-optical density response in a narrow range around the prescribed dose, as well as their capability to be fixed to the shielding disk without giving any distortion in the dose distribution. Off-line analysis of the radiochromic film allowed absolute dose measurements and this is indeed a very important verification of the correct exposure to the target organ, as well as an estimate of the dose to the healthy tissue underlying the shielding. These dose maps allow surgeons and radiation oncologists to take advantage of qualitative and quantitative feedback for setting more accurate treatment strategies and further optimized procedures. The proper alignment using elastic bands has improved the absolute dose accuracy and the collimator disk alignment by more than 50%.
Bel, E. H.; Zwinderman, A. H.; Timmers, M. C.; Dijkman, J. H.; Sterk, P. J.
1991-01-01
Beta 2 agonists reduce airway hypersensitivity to bronchoconstrictor stimuli acutely in patients with asthma and chronic obstructive lung disease. To determine whether these drugs also protect against excessive airway narrowing, the effect of inhaled salbutamol on the position and shape of the dose-response curves for histamine or methacholine was investigated in 12 patients with asthma and 11 with chronic obstructive lung disease. After pretreatment with salbutamol (200 or 400 micrograms) or placebo in a double blind manner dose-response curves for inhaled histamine and methacholine were obtained by a standard method on six days in random order. Airway sensitivity was defined as the concentration of histamine or methacholine causing a 20% fall in FEV1 (PC20). A maximal response plateau on the log dose-response curve was considered to be present if two or more data points for FEV1 fell within a 5% response range. In the absence of a plateau, the test was continued until a predetermined level of severe bronchoconstriction was reached. Salbutamol caused an acute increase in FEV1 (mean increase 11.5% predicted in asthma, 7.2% in chronic obstructive lung disease), and increase in PC20 (mean 15 fold in asthma, fivefold in chronic obstructive lung disease), and an increase in the slope of the dose-response curves in both groups. In subjects in whom a plateau of FEV1 response could be measured salbutamol did not change the level of the plateau. In subjects without a plateau salbutamol did not lead to the development of a plateau, despite achieving a median FEV1 of 44% predicted in asthma and 39% in chronic obstructive lung disease. These results show that, although beta 2 agonists acutely reduce the airway response to a given strength of bronchoconstrictor stimulus, they do not protect against excessive airflow obstruction if there is exposure to relatively strong stimuli. This, together with the steepening of the dose-response curve, could be a disadvantage of beta 2 agonists in the treatment of moderate and severe asthma or chronic obstructive lung disease. PMID:1871705
Kavuzlu, Ali; Arslan, Necmi; Tastan, Eren; Islam, Ahmet; Ustun, Huseyin; Aydogan, Filiz
2011-11-01
The aim of our study was to investigate the effect of the topical use of mitomycin C (MMC) intraoperatively in single dose and intra-postoperatively in two doses on the narrowing of antrostomy in maxillary rabbit sinus antrostomies created experimentally. And also to determine the local and systemic side effects of topical MMC. With this objective, 0.6 mg/ml MMC was used to the first group at single dose and to the second group intraoperatively and on third day postoperatively in two doses topically for 5 min. After 8 weeks, although the mean area of antrostomy was larger than that in the control side in the first group, which received single dose MMC, the difference was not statistically significant (p = 0.287). The second group received two doses, and the antrostomy areas were found to be significantly larger than the controls (p = 0.05). Overall, the sides that received MMC were significantly larger (p = 0.029). From the point of histopathological examination of the tissue, it was seen that two-dose MMC increased the edema indicating inflammation and antrostomy resolved with normal respiratory tract epithelium. It was shown by measuring the blood values that nephrotoxic and myelosupressant effect of MMC occurring in systemic use did not occur with single or double dose topical use. Our results demonstrate that even if the number of cases was low, two doses of topical MMC usage prevent the narrowing of antrostomy while single dose MMC does not. And two-dose topical MMC usage does not have local and systemic side effects.
de Denaro, Mario; Bortul, Marina; Vidali, Cristiana; Beorchia, Aulo
2014-01-01
Intraoperative electron radiation therapy (IOERT) cannot usually benefit, as conventional external radiotherapy, from software systems of treatment planning based on computed tomography and from common dose verify procedures. For this reason, in vivo film dosimetry (IVFD) proves to be an effective methodology to evaluate the actual radiation dose delivered to the target. A practical method for IVFD during breast IOERT was carried out to improve information on the dose actually delivered to the tumor target and on the alignment of the shielding disk with respect to the electron beam. Two EBT3 GAFCHROMIC films have been positioned on the two sides of the shielding disk in order to obtain the dose maps at the target and beyond the disk. Moreover the postprocessing analysis of the dose distribution measured on the films provides a quantitative estimate of the misalignment between the collimator and the disk. EBT3 radiochromic films have been demonstrated to be suitable dosimeters for IVD due to their linear dose‐optical density response in a narrow range around the prescribed dose, as well as their capability to be fixed to the shielding disk without giving any distortion in the dose distribution. Off‐line analysis of the radiochromic film allowed absolute dose measurements and this is indeed a very important verification of the correct exposure to the target organ, as well as an estimate of the dose to the healthy tissue underlying the shielding. These dose maps allow surgeons and radiation oncologists to take advantage of qualitative and quantitative feedback for setting more accurate treatment strategies and further optimized procedures. The proper alignment using elastic bands has improved the absolute dose accuracy and the collimator disk alignment by more than 50%. PACS number: 87.55.kh
Markle, Tricia M; Kozak, Kenneth H
2018-05-01
Thermal acclimation is hypothesized to offer a selective advantage in seasonal habitats and may underlie disparities in geographic range size among closely-related species with similar ecologies. Understanding this relationship is also critical for identifying species that are more sensitive to warming climates. Here, we study North American plethodontid salamanders to investigate whether acclimation ability is associated with species' latitudinal extents and the thermal range of the environments they inhabit. We quantified variation in thermal physiology by measuring standard metabolic rate (SMR) at different test and acclimation temperatures for 16 species of salamanders with varying latitudinal extents. A phylogenetically-controlled Markov chain Monte Carlo generalized linear mixed model (MCMCglmm) was then employed to determine whether there are differences in SMR between wide- and narrow-ranging species at different acclimation temperatures. In addition, we tested for a relationship between the acclimation ability of species and the environmental temperature ranges they inhabit. Further, we investigated if there is a trade-off between critical thermal maximum (CTMax) and thermal acclimation ability. MCMCglmm results show a significant difference in acclimation ability between wide and narrow-ranging temperate salamanders. Salamanders with wide latitudinal distributions maintain or slightly increase SMR when subjected to higher test and acclimation temperatures, whereas several narrow-ranging species show significant metabolic depression. We also found significant, positive relationships between acclimation ability and environmental thermal range, and between acclimation ability and CTMax. Wide-ranging salamander species exhibit a greater capacity for thermal acclimation than narrow-ranging species, suggesting that selection for acclimation ability may have been a key factor enabling geographic expansion into areas with greater thermal variability. Further, given that narrow-ranging salamanders are found to have both poor acclimation ability and lower tolerance to warm temperatures, they are likely to be more susceptible to environmental warming associated with anthropogenic climate change.
A review on therapeutic drug monitoring of immunosuppressant drugs.
Mohammadpour, Niloufar; Elyasi, Sepideh; Vahdati, Naser; Mohammadpour, Amir Hooshang; Shamsara, Jamal
2011-11-01
: Immunosuppressants require therapeutic drug monitoring because of their narrow therapeutic index and significant inter-individual variability in blood concentrations. This variability can be because of factors like drug-nutrient interactions, drug-disease interactions, renal-insufficiency, inflammation and infection, gender, age, polymorphism and liver mass. Drug monitoring is widely practiced especially for cyclosporine, tacrolimus, sirolimus and mycophenolic acid. CYCLOSPORINE: Therapeutic monitoring of immunosuppressive therapy with cyclosporine is a critical requirement because of intra- and inter-patient variability of drug absorption, narrow therapeutic window and drug induced nephrotoxicity. MYCOPHENOLIC ACID MPA: Some reasons for therapeutic drug monitoring of MPA during post-transplant period include: relationship between MPA pharmacokinetic parameters and clinical outcomes, Inter-patient pharmacokinetic variability for MPA despite fixed MMF doses, alternations of MPA pharmacokinetics during the first months after transplantation, drug- drug interaction and influence of kidney function on MPA pharmacokinetic. SIROLIMUS: A recent review of the pharmacokinetics of sirolimus suggested a therapeutic range of 5 to 10 μg l(-1) in whole blood. However, the only consensus guidelines published on the therapeutic monitoring of sirolimus concluded that there was not enough information available about the clinical use of the drug to make recommendations. TACROLIMUS: Sudies have shown, in kidney and liver transplant patients, significant associations of low tacrolimus concentrations with rejection and of high concentrations with nephrotoxicity. Although the feasibility of a limited sampling scheme to predict AUC has been demonstrated, as yet, trough, or pre-dose, whole blood concentration monitoring is still the method of choice.
Damage buildup in Ar-ion-irradiated 3 C-SiC at elevated temperatures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wallace, J. B.; Bayu Aji, L. B.; Li, T. T.
Above room temperature, the accumulation of radiation damage in 3 C-SiC is strongly influenced by dynamic defect interaction processes and remains poorly understood. Here, we use a combination of ion channeling and transmission electron microscopy to study lattice disorder in 3 C-SiC irradiated with 500 keV Ar ions in the temperature range of 25–250 °C. Results reveal sigmoidal damage buildup for all the temperatures studied. For 150 °C and below, the damage level monotonically increases with ion dose up to amorphization. Starting at 200 °C, the shape of damage–depth profiles becomes anomalous, with the damage peak narrowing and moving tomore » larger depths and an additional shoulder forming close to the ion end of range. As a result, damage buildup curves for 200 and 250 °C exhibit an anomalous two-step shape, with a damage saturation stage followed by rapid amorphization above a critical ion dose, suggesting a nucleation-limited amorphization behavior. Despite their complexity, all damage buildup curves are well described by a phenomenological model based on an assumption of a linear dependence of the effective amorphization cross section on ion dose. Here, in contrast to the results of previous studies, 3 C-SiC can be amorphized by bombardment with 500 keV Ar ions even at 250 °C with a relatively large dose rate of ~2×10 13 cm -2 s -1, revealing a dominant role of defect interaction dynamics at elevated temperatures.« less
Damage buildup in Ar-ion-irradiated 3 C-SiC at elevated temperatures
Wallace, J. B.; Bayu Aji, L. B.; Li, T. T.; ...
2015-09-14
Above room temperature, the accumulation of radiation damage in 3 C-SiC is strongly influenced by dynamic defect interaction processes and remains poorly understood. Here, we use a combination of ion channeling and transmission electron microscopy to study lattice disorder in 3 C-SiC irradiated with 500 keV Ar ions in the temperature range of 25–250 °C. Results reveal sigmoidal damage buildup for all the temperatures studied. For 150 °C and below, the damage level monotonically increases with ion dose up to amorphization. Starting at 200 °C, the shape of damage–depth profiles becomes anomalous, with the damage peak narrowing and moving tomore » larger depths and an additional shoulder forming close to the ion end of range. As a result, damage buildup curves for 200 and 250 °C exhibit an anomalous two-step shape, with a damage saturation stage followed by rapid amorphization above a critical ion dose, suggesting a nucleation-limited amorphization behavior. Despite their complexity, all damage buildup curves are well described by a phenomenological model based on an assumption of a linear dependence of the effective amorphization cross section on ion dose. Here, in contrast to the results of previous studies, 3 C-SiC can be amorphized by bombardment with 500 keV Ar ions even at 250 °C with a relatively large dose rate of ~2×10 13 cm -2 s -1, revealing a dominant role of defect interaction dynamics at elevated temperatures.« less
Neurosurgical applications of ion beams
NASA Astrophysics Data System (ADS)
Fabrikant, Jacob I.; Levy, Richard P.; Phillips, Mark H.; Frankel, Kenneth A.; Lyman, John T.
1989-04-01
The program at Donner Pavilion has applied nuclear medicine research to the diagnosis and radiosurgical treatment of life-threatening intracranial vascular disorders that affect more than half a million Americans. Stereotactic heavy-charged-particle Bragg peak radiosurgery, using narrow beams of heavy ions, demonstrates superior biological and physical characteristics in brain over X-and γ-rays, viz., improved dose distribution in the Bragg peak and sharp lateral and distal borders and less scattering of the beam. Examination of CNS tissue response and alteration of cerebral blood-flow dynamics related to heavy-ion Bragg peak radiosurgery is carried out using three-dimensional treatment planning and quantitative imaging utilizing cerebral angiography, computerized tomography (CT), magnetic resonance imaging (MRI), cine-CT, xenon X-ray CT and positron emission tomography (PET). Also under examination are the physical properties of narrow heavy-ion beams for improving methods of dose delivery and dose distribution and for establishing clinical RBE/LET and dose-response relationships for human CNS tissues. Based on the evaluation and treatment with stereotactically directed narrow beams of heavy charged particles of over 300 patients, with cerebral angiography, CT scanning and MRI and PET scanning of selected patients, plus extensive clinical and neuroradiological followup, it appears that Stereotactic charged-particle Bragg peak radiosurgery obliterates intracranial arteriovenous malformations or protects against rebleeding with reduced morbidity and no mortality. Discussion will include the method of evaluation, the clinical research protocol, the Stereotactic neuroradiological preparation, treatment planning, the radiosurgery procedure and the protocol for followup. Emphasis will be placed on the neurological results, including the neuroradiological and clinical response and early and late delayed injury in brain leading to complications (including vasogenic edema, arterial occlusion, venous thrombosis and radiation necrosis). Clinical results in both children and adults will be illustrated and health outcome will be related to the advantages of charged-particle treatment planning, the radiosurgical procedure, dose distribution and dose localization.
Tsutsui-Kimura, Iku; Ohmura, Yu; Yoshida, Takayuki; Yoshioka, Mitsuhiro
2017-07-01
Serotonin/noradrenaline reuptake inhibitors (SNRIs) are widely used for the treatment for major depressive disorder, but these drugs induce several side effects including increased aggression and impulsivity, which are risk factors for substance abuse, criminal involvement, and suicide. To address this issue, milnacipran (0, 3, 10, or 30 mg/kg), an SNRI and antidepressant, was intraperitoneally administered to mice prior to the 3-choice serial reaction time task, resident-intruder test, and forced swimming test to measure impulsive, aggressive, and depressive-like behaviors, respectively. A milnacipran dose of 10 mg/kg suppressed all behaviors, which was accompanied by increased dopamine and serotonin levels in the medial prefrontal cortex (mPFC) but not in the nucleus accumbens (NAc). Although the most effective dose for depressive-like behavior was 30 mg/kg, the highest dose increased aggressive behavior and unaffected impulsive behavior. Increased dopamine levels in the NAc could be responsible for the effects. In addition, the mice basal impulsivity was negatively correlated with the latency to the first agonistic behavior. Thus, the optimal dose range of milnacipran is narrower than previously thought. Finding drugs that increase serotonin and dopamine levels in the mPFC without affecting dopamine levels in the NAc is a potential strategy for developing novel antidepressants. Copyright © 2017 The Authors. Production and hosting by Elsevier B.V. All rights reserved.
Santibáñez, M; Saavedra, R; Vásquez, M; Malano, F; Pérez, P; Valente, M; Figueroa, R G
2017-11-01
The present work is devoted to optimizing the sensitivity-doses relationship of a bench-top EDXRF system, with the aim of achieving a detection limit of 0.010mg/ml of gold nanoparticles in tumor tissue (clinical values expected), for doses below 10mGy (value fixed for in vivo application). Tumor phantoms of 0.3cm 3 made of a suspension of gold nanoparticles (15nm AurovistTM, Nanoprobes Inc.) were studied at depths of 0-4mm in a tissue equivalent cylindrical phantom. The optimization process was implemented configuring several tube voltages and aluminum filters, to obtain non-symmetrical narrow spectra with fixed FWHM of 5keV and centered among the 11.2-20.3keV. The used statistical figure of merit was the obtained sensitivity (with each spectrum at each depth) weighted by the delivered surface doses. The detection limit of the system was determined measuring several gold nanoparticles concentrations ranging from 0.0010 to 5.0mg/ml and a blank sample into tumor phantoms, considering a statistical fluctuation within 95% of confidence. The results show the possibility of obtaining a detection limit for gold nanoparticles concentrations around 0.010mg/ml for surface tumor phantoms requiring doses around 2mGy. Copyright © 2017 Elsevier Ltd. All rights reserved.
Diabetes Prevention Program Community Outreach Perspectives on Lifestyle Training and Translation
Venditti, Elizabeth M.; Kramer, M. Kaye
2013-01-01
The gap between what is known from clinical efficacy research and the systematic community translation of diabetes prevention programs is narrowing. During the past 5 years, numerous randomized and nonrandomized dissemination studies have evaluated the modified delivery of structured Diabetes Prevention Program (DPP) interventions in diverse real-world settings. Programs of sufficient dose and duration, implemented with fidelity, have reported weight losses in the range of 4%–7% with associated improvements in cardiometabolic risk factors at 6 and 12 months from baseline. The current article describes some of the experiences and perspectives of a team of University of Pittsburgh researchers as they have engaged in these efforts. PMID:23498296
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jensen, Ingelise, E-mail: inje@rn.d; Carl, Jesper; Lund, Bente
2011-07-01
Dose escalation in prostate radiotherapy is limited by normal tissue toxicities. The aim of this study was to assess the impact of margin size on tumor control and side effects for intensity-modulated radiation therapy (IMRT) and 3D conformal radiotherapy (3DCRT) treatment plans with increased dose. Eighteen patients with localized prostate cancer were enrolled. 3DCRT and IMRT plans were compared for a variety of margin sizes. A marker detectable on daily portal images was presupposed for narrow margins. Prescribed dose was 82 Gy within 41 fractions to the prostate clinical target volume (CTV). Tumor control probability (TCP) calculations based on themore » Poisson model including the linear quadratic approach were performed. Normal tissue complication probability (NTCP) was calculated for bladder, rectum and femoral heads according to the Lyman-Kutcher-Burman method. All plan types presented essentially identical TCP values and very low NTCP for bladder and femoral heads. Mean doses for these critical structures reached a minimum for IMRT with reduced margins. Two endpoints for rectal complications were analyzed. A marked decrease in NTCP for IMRT plans with narrow margins was seen for mild RTOG grade 2/3 as well as for proctitis/necrosis/stenosis/fistula, for which NTCP <7% was obtained. For equivalent TCP values, sparing of normal tissue was demonstrated with the narrow margin approach. The effect was more pronounced for IMRT than 3DCRT, with respect to NTCP for mild, as well as severe, rectal complications.« less
Hodel, Eva Maria; Kaur, Harparkash; Terlouw, Dianne J
2017-02-08
Dihydroartemisinin-piperaquine (DP) is recommended for the treatment of uncomplicated malaria, used in efforts to contain artemisinin resistance, and increasingly considered for mass drug administration. Because of the narrow therapeutic dose range and available tablet strengths, the manufacturers and World Health Organization recommended regimens involve breaking tablets into halves to accurately dose children according to body weight. Use of tablet fractions in programmatic settings under tropical conditions requires a highly stable product; however, the stability of DP tablet fractions is unknown. We aged full and half DP (Eurartesim ® ) tablets in a stability chamber at 30°C and 70% humidity level. The active pharmaceutical ingredients dihydroartemisinin and piperaquine remained at ≥ 95% over the 3 months' period of ageing in light and darkness. These findings are reassuring for DP, but highlight the need to assess drug stability under real-life settings during the drug development process, particularly for key drugs of global disease control programs. © The American Society of Tropical Medicine and Hygiene.
An autopsy case of acetyl fentanyl intoxication caused by insufflation of 'designer drugs'.
Takase, Izumi; Koizumi, Takako; Fujimoto, Ihoko; Yanai, Aya; Fujimiya, Tatsuya
2016-07-01
We present a fatal case of intoxication due to insufflation of acetyl fentanyl. His blood concentration of acetyl fentanyl was 270ng/mL, and the manner of death was classified as an accident. This is the first report of an autopsy case of acetyl fentanyl delivered by insufflation, rather than intravenous administration. He had been snoring loudly for at least 12h prior to death, and transport to a hospital during this time and treatment with naloxone may have saved his life. In this sense, it can be said that his death was preventable. This case reemphasizes the risk of death associated with drug overdose and the narrow range of acetyl fentanyl between the effective dose (ED50) and lethal dose (LD50). The case should also raise awareness among medical professionals of the effectiveness of naloxone and the need to establish a comprehensive system for toxicological analysis while keeping the possibility of use of 'designer drugs' in mind. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Capote, Roberto; Sánchez-Doblado, Francisco; Leal, Antonio; Lagares, Juan Ignacio; Arráns, Rafael; Hartmann, Günther H
2004-09-01
Intensity modulated radiation therapy (IMRT) has evolved toward the use of many small radiation fields, or "beamlets," to increase the resolution of the intensity map. The size of smaller beamlets can be typically about 1-5 cm2. Therefore small ionization chambers (IC) with sensitive volumes < or = 0.1 cm3 are generally used for dose verification of IMRT treatment. The dosimetry of these narrow photon beams pertains to the so-called nonreference conditions for beam calibration. The use of ion chambers for such narrow beams remains questionable due to the lack of electron equilibrium in most of the field. The present contribution aims to estimate, by the Monte Carlo (MC) method, the total correction needed to convert the IBA-Wellhöfer NAC007 micro IC measured charge in such radiation field to the absolute dose to water. Detailed geometrical simulation of the microionization chamber was performed. The ion chamber was always positioned at a 10 cm depth in water, parallel to the beam axis. The delivered doses to air and water cavity were calculated using the CAVRZ EGSnrc user code. The 6 MV phase-spaces for Primus Clinac (Siemens) used as an input to the CAVRZnrc code were derived by BEAM/EGS4 modeling of the treatment head of the machine along with the multileaf collimator [Sánchez-Doblado et al., Phys. Med. Biol. 48, 2081-2099 (2003)] and contrasted with experimental measurements. Dose calculations were carried out for two irradiation geometries, namely, the reference 10x10 cm2 field and an irregular (approximately 2x2 cm2) IMRT beamlet. The dose measured by the ion chamber is estimated by MC simulation as a dose averaged over the air cavity inside the ion-chamber (Dair). The absorbed dose to water is derived as the dose deposited inside the same volume, in the same geometrical position, filled and surrounded by water (Dwater) in the absence of the ionization chamber. Therefore, the Dwater/Dair dose ratio is a MC direct estimation of the total correction factor needed to convert the absorbed dose in air to absorbed dose to water. The dose ratio was calculated for several chamber positions, starting from the penumbra region around the beamlet along the two diagonals crossing the radiation field. For this quantity from 0 up to a 3% difference is observed between the dose ratio values obtained within the small irregular IMRT beamlet in comparison with the dose ratio derived for the reference 10x10 cm2 field. Greater differences from the reference value up to 9% were obtained in the penumbra region of the small IMRT beamlet.
NASA Astrophysics Data System (ADS)
Pritchard, M.; Craven, T.; Mkandawire, T.; Edmondson, A. S.; O'Neill, J. G.
The powder obtained from the seeds of the Moringa oleifera tree has been shown to be an effective primary coagulant for water treatment. When the seeds are dried, dehusked, crushed and added to water, the powder acts as a coagulant binding colloidal particles and bacteria to form agglomerated particles (flocs), which settle allowing the clarified supernatant to be poured off. Very little research has been undertaken on the parameters affecting the effectiveness of M. oleifera, especially in Malawi, for purification of drinking water and there is a great need for further testing in this area. Conclusive data needs to be compiled to demonstrate the effects of various water parameters have on the efficiency of the seeds. A parametric study was undertaken at Leeds Metropolitan University, UK, with the aim to establish the most appropriate dosing method; the optimum dosage for removal of turbidity; the influence of pH and temperature; together with the shelf life of the M. oleifera seeds. The study revealed that the most suitable dosing method was to mix the powder into a concentrated paste, hence forming a stock suspension. The optimum M. oleifera dose, for turbidity values between 40 and 200 NTU, ranged between 30 and 55 mg/l. With turbidity set at 130 NTU and a M. oleifera dose within the optimum range at 50 mg/l, pH levels were varied between 4 and 9. It was discovered that the coagulant performance was not too sensitive to pH fluctuations when conditions were within the optimum range. The most efficient coagulation, determined by the greatest reduction in turbidity, occurred at pH 6.5. Alkaline conditions were overall more favourable than acidic conditions; pH 9 had an efficiency of 65% of optimum, whilst at pH 5 the efficiency dropped to around 55%. The efficiency further dropped at pH 4, where the powder only produced results of around 10% of optimum conditions. A temperature range of 4-60 °C was studied in this research. Colder waters (<15 °C) were found to hinder the effectiveness of the coagulation process. The higher the temperature the more effective was the coagulation. It was also found that the age of the seeds, up to 18 months, did not have any noticeable effect on dose level and percentage reduction in turbidity, although at 18 months the seeds had a narrower dosing range to produce near-optimum reduction. Seeds aged 24 months showed a significant decline in coagulant efficiency.
SU-F-P-21: Study of Dosimetry Accuracy of Small Passively Scattered Proton Beam Fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Y; Gautam, A; Kerr, M
2016-06-15
Purpose: To study the accuracy of the dose distribution of very small irregular fields of passively scattered proton beams calculated by the analytical pencil beam model of the Eclipse treatment planning system (TPS). Methods: An irregular field with a narrow region (width < 1 cm) that was used for the treatment of a small volume adjacent to a previously treated area were chosen for this investigation. Point doses at different locations inside the field were measured with a small volume ion chamber (A26, Standard Imaging). 2-D dose distributions were measured using a 2-D ion chamber array (MatriXX, IBA). All themore » measurements were done in plastic water phantom. The measured dose distributions were compared with the verification plan dose calculated in a water like phantom for the patient treatment field without the use of the compensator. Results: Point doses measured with the ion chamber in the narrowest section of the field were found to differ as much as 10% from the Eclipse calculated dose at some of the points. The 2-D dose distribution measured with the MatriXX which was validated by comparison with limited film measurement, at the proximal 95%, center of the spread out Bragg Peak and distal 90% depths agreed reasonably well with the TPS calculated dose distribution with more than 92% of the pixels passing the 2% / 2 mm dose distance agreement. Conclusion: The dose calculated by the pencil beam model of the Eclipse TPS for narrow irregular fields may not be accurate within 5% at some locations of the field, especially at the points close to the field edge due to the limitation of the dose calculation model. Overall accuracy of the calculated 2-D dose distribution was found to be acceptable for the 2%/2 mm dose/distance agreement with the measurement.« less
Potential High Resolution Dosimeters For MRT
NASA Astrophysics Data System (ADS)
Bräuer-Krisch, E.; Rosenfeld, A.; Lerch, M.; Petasecca, M.; Akselrod, M.; Sykora, J.; Bartz, J.; Ptaszkiewicz, M.; Olko, P.; Berg, A.; Wieland, M.; Doran, S.; Brochard, T.; Kamlowski, A.; Cellere, G.; Paccagnella, A.; Siegbahn, E. A.; Prezado, Y.; Martinez-Rovira, I.; Bravin, A.; Dusseau, L.; Berkvens, P.
2010-07-01
Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow (˜25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 μm microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic® films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al2O3:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1×1 cm5 field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.
2012-01-01
Background Hemorrhagic events are frequent in patients on treatment with antivitamin-K oral anticoagulants due to their narrow therapeutic margin. Studies performed with acenocoumarol have shown the relationship between demographic, clinical and genotypic variants and the response to these drugs. Once the influence of these genetic and clinical factors on the dose of acenocoumarol needed to maintain a stable international normalized ratio (INR) has been demonstrated, new strategies need to be developed to predict the appropriate doses of this drug. Several pharmacogenetic algorithms have been developed for warfarin, but only three have been developed for acenocoumarol. After the development of a pharmacogenetic algorithm, the obvious next step is to demonstrate its effectiveness and utility by means of a randomized controlled trial. The aim of this study is to evaluate the effectiveness and efficiency of an acenocoumarol dosing algorithm developed by our group which includes demographic, clinical and pharmacogenetic variables (VKORC1, CYP2C9, CYP4F2 and ApoE) in patients with venous thromboembolism (VTE). Methods and design This is a multicenter, single blind, randomized controlled clinical trial. The protocol has been approved by La Paz University Hospital Research Ethics Committee and by the Spanish Drug Agency. Two hundred and forty patients with VTE in which oral anticoagulant therapy is indicated will be included. Randomization (case/control 1:1) will be stratified by center. Acenocoumarol dose in the control group will be scheduled and adjusted following common clinical practice; in the experimental arm dosing will be following an individualized algorithm developed and validated by our group. Patients will be followed for three months. The main endpoints are: 1) Percentage of patients with INR within the therapeutic range on day seven after initiation of oral anticoagulant therapy; 2) Time from the start of oral anticoagulant treatment to achievement of a stable INR within the therapeutic range; 3) Number of INR determinations within the therapeutic range in the first six weeks of treatment. Discussion To date, there are no clinical trials comparing pharmacogenetic acenocoumarol dosing algorithm versus routine clinical practice in VTE. Implementation of this pharmacogenetic algorithm in the clinical practice routine could reduce side effects and improve patient safety. Trial registration Eudra CT. Identifier: 2009-016643-18. PMID:23237631
NASA Astrophysics Data System (ADS)
Hunter, Craig R.; Jones, Brynmor E.; Schlosser, Peter; Sørensen, Simon Toft; Strain, Michael J.; McKnight, Loyd J.
2018-02-01
This paper will present developments in narrow-linewidth semiconductor-disk-laser systems using novel frequencystabilisation schemes for reduced sensitivity to mechanical vibrations, a critical requirement for mobile applications. Narrow-linewidth single-frequency lasers are required for a range of applications including metrology and highresolution spectroscopy. Stabilisation of the laser was achieved using a monolithic fibre-optic ring resonator with free spectral range of 181 MHz and finesse of 52 to act as passive reference cavity for the laser. Such a cavity can operate over a broad wavelength range and is immune to a wide band of vibrational frequency noise due to its monolithic implementation. The frequency noise of the locked system has been measured and compared to typical Fabry-Perotlocked lasers using vibration equipment to simulate harsh environments, and analysed here. Locked linewidths of < 40 kHz have been achieved. These developments offer a portable, narrow-linewidth laser system for harsh environments that can be flexibly designed for a range of applications.
SU-D-201-02: Prediction of Delivered Dose Based On a Joint Histogram of CT and FDG PET Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, M; Choi, Y; Cho, A
2015-06-15
Purpose: To investigate whether pre-treatment images can be used in predicting microsphere distribution in tumors. When intra-arterial radioembolization using Y90 microspheres was performed, the microspheres were often delivered non-uniformly within the tumor, which could lead to an inefficient therapy. Therefore, it is important to estimate the distribution of microspheres. Methods: Early arterial phase CT and FDG PET images were acquired for patients with primary liver cancer prior to radioembolization (RE) using Y90 microspheres. Tumor volume was delineated on CT images and fused with FDG PET images. From each voxel (3.9×3.9×3.3 mm3) in the tumor, the Hounsfield unit (HU) from themore » CT and SUV values from the FDG PET were harvested. We binned both HU and SUV into 11 bins and then calculated a normalized joint-histogram in an 11×11 array.Patients also underwent a post-treatment Y90 PET imaging. Radiation dose for the tumor was estimated using convolution of the Y90 distribution with a dose-point kernel. We also calculated a fraction of the tumor volume that received a radiation dose great than 100Gy. Results: Averaged over 40 patients, 55% of tumor volume received a dose greater than 100Gy (range : 1.1 – 100%). The width of the joint histogram was narrower for patients with a high dose. For patients with a low dose, the width was wider and a larger fraction of tumor volume had low HU. Conclusion: We have shown the pattern of joint histogram of the HU and SUV depends on delivered dose. The patterns can predict the efficacy of uniform intra-arterial delivery of Y90 microspheres.« less
Lemoine, Adrien; Mazoit, Jean X; Bonnet, Francis
2016-11-01
Spinal bupivacaine is used for day-case surgery but the appropriate dose that guarantees hospital discharge is unknown. We sought to determine the spinal bupivacaine dose that prevents delayed hospital discharge in ambulatory surgery. Systematic review of clinical trials. Comprehensive search in electronic databases of studies published between 1996 and 2014 reporting the use of spinal bupivacaine in ambulatory patients. Additional articles were retrieved through hyperlinks and by manually searching reference lists in original articles, review articles and correspondence published in English and French. Data were used to calculate, motor block duration and discharge time, an estimated maximal effect (Emax: maximum theoretical time of motor block) and the effective dose to obtain half of Emax (D50) with 95% confidence intervals (CIs). A simulation was performed to determine the dose corresponding to a time to recovery of 300 min for motor function, and 360 min for discharge, in 95% of the patients. In total, 23 studies (1062 patients) were included for analysis of the time to recovery of motor function, and 12 studies (618 patients) for the time to hospital discharge. The Emax for recovery of motor function was 268 min [95% CI (189 to 433 min)] and the D50 was 3.9 mg [95% CI (2.3 to 6.2 mg)]. A 7.5-mg dose of bupivacaine enables resolution of motor block and ambulation within 300 min in 95% of the patients. A 5-mg dose or less was associated with an unacceptable failure rate. Ambulatory surgery is possible under spinal anaesthesia with bupivacaine although the dose range that ensures reliable anaesthesia with duration short enough to guarantee ambulatory management is narrow.
Freitas, Kelen; Carroll, F. Ivy; Negus, S. Stevens
2015-01-01
Intracranial self-stimulation (ICSS) is one type of preclinical procedure for research on pharmacological mechanisms that mediate abuse potential of drugs acting at various targets including nicotinic acetylcholine receptors (nAChRs). This study compared effects of the non-selective nAChR agonist nicotine (0.032-1.0 mg/kg) and the α4β2-selective nAChR agonist 5-I-A-85380 (0.01-1.0 mg/kg) on ICSS in male Sprague-Dawley rats. Rats were implanted with electrodes targeting the medial forebrain bundle at the level of the lateral hypothalamus and trained to respond under a fixed-ratio 1 schedule for a range of brain stimulation frequencies (158-56 Hz). A broad range of 5-I-A-85380 doses produced an abuse-related increase (or “facilitation”) of low ICSS rates maintained by low brain-stimulation frequencies, and this effect was blocked by both the nonselective nAChR antagonist mecamylamine and the selective α4β2 antagonist dihyrdo-ß-erythroidine (DHßE). Conversely, nicotine produced weaker ICSS facilitation across a narrower range of doses, and higher nicotine doses decreased high rates of ICSS maintained by high brain- stimulation frequencies. The rate-decreasing effects of a high nicotine dose were blocked by mecamylamine but not DHßE. Chronic nicotine treatment produced selective tolerance to rate-decreasing effects of nicotine but did not alter ICSS rate-increasing effects of nicotine. These results suggest that α4β2 receptors are sufficient to mediate abuse-related rate-increasing effects of nAChR agonists in this ICSS procedure. Conversely, nicotine effects at non-α4β2 nAChRs appear to oppose and limit abuse-related effects mediated by α4β2 receptors, although tolerance can develop to these non-α4β2 effects. Selective α4β2 agonists may have higher abuse potential than nicotine. PMID:26461167
Terkola, R; Czejka, M; Bérubé, J
2017-08-01
Medication errors are a significant cause of morbidity and mortality especially with antineoplastic drugs, owing to their narrow therapeutic index. Gravimetric workflow software systems have the potential to reduce volumetric errors during intravenous antineoplastic drug preparation which may occur when verification is reliant on visual inspection. Our aim was to detect medication errors with possible critical therapeutic impact as determined by the rate of prevented medication errors in chemotherapy compounding after implementation of gravimetric measurement. A large-scale, retrospective analysis of data was carried out, related to medication errors identified during preparation of antineoplastic drugs in 10 pharmacy services ("centres") in five European countries following the introduction of an intravenous workflow software gravimetric system. Errors were defined as errors in dose volumes outside tolerance levels, identified during weighing stages of preparation of chemotherapy solutions which would not otherwise have been detected by conventional visual inspection. The gravimetric system detected that 7.89% of the 759 060 doses of antineoplastic drugs prepared at participating centres between July 2011 and October 2015 had error levels outside the accepted tolerance range set by individual centres, and prevented these doses from reaching patients. The proportion of antineoplastic preparations with deviations >10% ranged from 0.49% to 5.04% across sites, with a mean of 2.25%. The proportion of preparations with deviations >20% ranged from 0.21% to 1.27% across sites, with a mean of 0.71%. There was considerable variation in error levels for different antineoplastic agents. Introduction of a gravimetric preparation system for antineoplastic agents detected and prevented dosing errors which would not have been recognized with traditional methods and could have resulted in toxicity or suboptimal therapeutic outcomes for patients undergoing anticancer treatment. © 2017 The Authors. Journal of Clinical Pharmacy and Therapeutics Published by John Wiley & Sons Ltd.
Barnes, M P; Ebert, M A
2008-03-01
The concept of electron pencil-beam dose distributions is central to pencil-beam algorithms used in electron beam radiotherapy treatment planning. The Hogstrom algorithm, which is a common algorithm for electron treatment planning, models large electron field dose distributions by the superposition of a series of pencil beam dose distributions. This means that the accurate characterisation of an electron pencil beam is essential for the accuracy of the dose algorithm. The aim of this study was to evaluate a measurement based approach for obtaining electron pencil-beam dose distributions. The primary incentive for the study was the accurate calculation of dose distributions for narrow fields as traditional electron algorithms are generally inaccurate for such geometries. Kodak X-Omat radiographic film was used in a solid water phantom to measure the dose distribution of circular 12 MeV beams from a Varian 21EX linear accelerator. Measurements were made for beams of diameter, 1.5, 2, 4, 8, 16 and 32 mm. A blocked-field technique was used to subtract photon contamination in the beam. The "error function" derived from Fermi-Eyges Multiple Coulomb Scattering (MCS) theory for corresponding square fields was used to fit resulting dose distributions so that extrapolation down to a pencil beam distribution could be made. The Monte Carlo codes, BEAM and EGSnrc were used to simulate the experimental arrangement. The 8 mm beam dose distribution was also measured with TLD-100 microcubes. Agreement between film, TLD and Monte Carlo simulation results were found to be consistent with the spatial resolution used. The study has shown that it is possible to extrapolate narrow electron beam dose distributions down to a pencil beam dose distribution using the error function. However, due to experimental uncertainties and measurement difficulties, Monte Carlo is recommended as the method of choice for characterising electron pencil-beam dose distributions.
NASA Astrophysics Data System (ADS)
Kuess, Peter; Böhlen, Till T.; Lechner, Wolfgang; Elia, Alessio; Georg, Dietmar; Palmans, Hugo
2017-12-01
Large area ionization chambers (LAICs) can be used to measure output factors of narrow beams. Dose area product measurements are proposed as an alternative to central-axis point dose measurements. Using such detectors requires detailed information on the uniformity of the response along the sensitive area. Eight LAICs were investigated in this study: four of type PTW-34070 (LAICThick) and four of type PTW-34080 (LAICThin). Measurements were performed in an x-ray unit using peak voltages of 100-200 kVp and a collimated beam of 3.1 mm (FWHM). The LAICs were moved with a step size of 5 mm to measure the chamber response at lateral positions. To account for beam positions where only a fraction of the beam impinged within the sensitive area of the LAICs, a corrected response was calculated which was the basis to calculate the relative response. The impact of a heterogeneous LAIC response, based on the obtained response maps was henceforth investigated for proton pencil beams and small field photon beams. A pronounced heterogeneity of the responses was observed in the investigated LAICs. The response of LAICThick generally decreased with increasing radius, resulting in a response correction of up to 5%. This correction was more pronounced and more diverse (up to 10%) for LAICThin. Considering a proton pencil beam the systematic offset for reference dosimetry was 2.4-4.1% for LAICThick and -9.5 to 9.4% for LAICThin. For relative dosimetry (e.g. integral depth-dose curves) systematic response variation by 0.8-1.9% were found. For a decreasing photon field size the systematic offset for absolute dose measurements showed a 2.5-4.5% overestimation of the response for 6 × 6 mm2 field sizes for LAICThick. For LAICThin the response varied even over a range of 20%. This study highlights the need for chamber-dependent response maps when using LAICs for absolute and relative dosimetry with proton pencil beams or small photon beams.
Jensen, Ingelise; Carl, Jesper; Lund, Bente; Larsen, Erik H; Nielsen, Jane
2011-01-01
Dose escalation in prostate radiotherapy is limited by normal tissue toxicities. The aim of this study was to assess the impact of margin size on tumor control and side effects for intensity-modulated radiation therapy (IMRT) and 3D conformal radiotherapy (3DCRT) treatment plans with increased dose. Eighteen patients with localized prostate cancer were enrolled. 3DCRT and IMRT plans were compared for a variety of margin sizes. A marker detectable on daily portal images was presupposed for narrow margins. Prescribed dose was 82 Gy within 41 fractions to the prostate clinical target volume (CTV). Tumor control probability (TCP) calculations based on the Poisson model including the linear quadratic approach were performed. Normal tissue complication probability (NTCP) was calculated for bladder, rectum and femoral heads according to the Lyman-Kutcher-Burman method. All plan types presented essentially identical TCP values and very low NTCP for bladder and femoral heads. Mean doses for these critical structures reached a minimum for IMRT with reduced margins. Two endpoints for rectal complications were analyzed. A marked decrease in NTCP for IMRT plans with narrow margins was seen for mild RTOG grade 2/3 as well as for proctitis/necrosis/stenosis/fistula, for which NTCP <7% was obtained. For equivalent TCP values, sparing of normal tissue was demonstrated with the narrow margin approach. The effect was more pronounced for IMRT than 3DCRT, with respect to NTCP for mild, as well as severe, rectal complications. Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kan, Tomoko, E-mail: tkan@grape.med.tottori-u.ac.j; Kodani, Kazuhiko; Michimoto, Koichi
Purpose: To elucidate the radiation-induced damage to the microstructure of the parotid gland using high-resolution magnetic resonance imaging. Methods and Materials: High-resolution magnetic resonance imaging of the parotid gland was performed before radiotherapy (RT) and during the RT period or {<=}3 weeks after RT completion for 12 head-and-neck cancer patients using a 1.5-T scanner with a microscopy coil. The maximal cross-sectional area of the gland was evaluated, and changes in the internal architecture of the gland were assessed both visually and quantitatively. Results: Magnetic resonance images were obtained at a median parotid gland dose of 36 Gy (range, 11-64). Accordingmore » to the quantitative analysis, the maximal cross-sectional area of the gland was reduced, the width of the main duct was narrowed, and the intensity ratio of the main duct lumen to background was significantly decreased after RT (p <.0001). According to the visual assessment, the width of the main duct tended to narrow and the contrast of the duct lumen tended to be decreased, but no significant differences were noted. The visibility of the duct branches was unclear in 10 patients (p = .039), and the septum became dense in 11 patients (p = .006) after RT. Conclusion: High-resolution magnetic resonance imaging is a noninvasive method of evaluating radiation-induced changes to the internal architecture of the parotid gland. Morphologic changes in the irradiated parotid gland were demonstrated during the RT course even when a relatively small dose was delivered to the gland.« less
Ultraviolet radiation effects on the infrared damage rate of a thermal control coating
NASA Technical Reports Server (NTRS)
Bass, J. A.
1972-01-01
The effects of ultraviolet radiation on the infrared reflectance of ZnO silicone white thermal coatings were investigated. Narrow band ultraviolet radiation for wavelengths in the 2200A to 3500A range by a monochromator and a high pressure, 150-W Eimac xenon lamp. The sample was irradiated while in a vacuum of at least 0.000001 torr, and infrared reflectance was measured in situ with a spectroreflectometer at 19,500A. Reflectance degradation was studied as a function of wavelength, time, intensity, and dose. Damage was wavelength dependent at constant exposure, but no maximum was evident above the shortest wavelength investigated here. The degradation rate at constant intensity was an exponential function of time and varies with intensity.
Wang, Xiaomeng; Li, Minghui; Song, Xiaojie; Chen, Zhihao; Wu, Bingdang; Zhang, Shujuan
2016-09-06
The nontoxicity of titanium (Ti) and the potential to produce valuable photocatalysts from the final coagulated sludge constitute the main advantages of Ti-based coagulants over conventional ones. However, the low effluent pH and the too-fast hydrolysis limit the wide application of Ti-salt coagulants. Prehydrolysis, to some extent, is helpful to improve the coagulation performance of Ti-salt coagulants. However, the prehydrolyzed polytitanium chloride (PTC) still suffers from narrow applicable dose/pH range. A novel and efficient Ti-based coagulant, denoted as titanium xerogel coagulant (TXC), was successfully prepared by the sol-gel method with TiCl4 as the precursor and acetylacetone as a modifying agent. Compared with TiCl4, a PTC, and a commercial polyferric sulfate, the resulting TXC possessed a larger floc size, better settling property, and wider applicable coagulant dose/pH range. Moreover, the effluent pH after TXC coagulation was not significantly reduced, avoiding the corrosion problem sometimes caused by the low effluent pH. TXC exhibited good coagulation performance for several real wastewaters, especially for the wastewaters of low turbidity. These results demonstrate that gelation was a more effective strategy than prehydrolysis to overcome the inherent weaknesses of Ti salts as a type of promising coagulants.
Lesche, Dorothea; Sigurdardottir, Vilborg; Setoud, Raschid; Englberger, Lars; Fiedler, Georg M; Largiadèr, Carlo R; Mohacsi, Paul; Sistonen, Johanna
2015-12-01
Everolimus (ERL) has become an alternative to calcineurin inhibitors (CNIs) due to its renal-sparing properties, especially in heart transplant (HTx) recipients with kidney dysfunction. However, ERL dosing is challenging due to its narrow therapeutic window combined with high interindividual pharmacokinetic variability. Our aim was to evaluate the effect of clinical and genetic factors on ERL dosing in a pilot cohort of 37 HTx recipients. Variants in CYP3A5, CYP3A4, CYP2C8, POR, NR1I2, and ABCB1 were genotyped, and clinical data were retrieved from patient charts. While ERL trough concentration (C0 ) was within the targeted range for most patients, over 30-fold variability in the dose-adjusted ERL C0 was observed. Regression analysis revealed a significant effect of the non-functional CYP3A5*3 variant on the dose-adjusted ERL C0 (p = 0.031). ERL dose requirement was 0.02 mg/kg/d higher in patients with CYP3A5*1/*3 genotype compared to patients with CYP3A5*3/*3 to reach the targeted C0 (p = 0.041). ERL therapy substantially improved estimated glomerular filtration rate (28.6 ± 6.6 mL/min/1.73 m(2)) in patients with baseline kidney dysfunction. Everolimus pharmacokinetics in HTx recipients is highly variable. Our preliminary data on patients on a CNI-free therapy regimen suggest that CYP3A5 genetic variation may contribute to this variability. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Total Dose Effects on Error Rates in Linear Bipolar Systems
NASA Technical Reports Server (NTRS)
Buchner, Stephen; McMorrow, Dale; Bernard, Muriel; Roche, Nicholas; Dusseau, Laurent
2007-01-01
The shapes of single event transients in linear bipolar circuits are distorted by exposure to total ionizing dose radiation. Some transients become broader and others become narrower. Such distortions may affect SET system error rates in a radiation environment. If the transients are broadened by TID, the error rate could increase during the course of a mission, a possibility that has implications for hardness assurance.
Chaswal, Vibha; Weldon, Michael; Gupta, Nilendu; Chakravarti, Arnab; Rong, Yi
2014-07-08
We present commissioning and comprehensive evaluation for ArcCHECK as a QA equipment for volumetric-modulated arc therapy (VMAT), using the 6 MV photon beam with and without the flattening filter, and the SNC patient software (version 6.2). In addition to commissioning involving absolute dose calibration, array calibration, and PMMA density verification, ArcCHECK was evaluated for its response dependency on linac dose rate, instantaneous dose rate, radiation field size, beam angle, and couch insertion. Scatter dose characterization, consistency and symmetry of response, and dosimetry accuracy evaluation for fixed aperture arcs and clinical VMAT patient plans were also investigated. All the evaluation tests were performed with the central plug inserted and the homogeneous PMMA density value. Results of gamma analysis demonstrated an overall agreement between ArcCHECK-measured and TPS-calculated reference doses. The diode based field size dependency was found to be within 0.5% of the reference. The dose rate-based dependency was well within 1% of the TPS reference, and the angular dependency was found to be ± 3% of the reference, as tested for BEV angles, for both beams. Dosimetry of fixed arcs, using both narrow and wide field widths, resulted in clinically acceptable global gamma passing rates on the 3%/3mm level and 10% threshold. Dosimetry of narrow arcs showed an improvement over published literature. The clinical VMAT cases demonstrated high level of dosimetry accuracy in gamma passing rates.
The practice and clinical implications of tablet splitting in international health
Elliott, Ivo; Mayxay, Mayfong; Yeuichaixong, Sengchanh; Lee, Sue J; Newton, Paul N
2014-01-01
Objective Tablet splitting is frequently performed to facilitate correct dosing, but the practice and implications in low-income settings have rarely been discussed. Methods We selected eight drugs, with narrow therapeutic indices or critical dosages, frequently divided in the Lao PDR (Laos). These were split, by common techniques used in Laos, by four nurses and four laypersons. The mean percentage deviation from the theoretical expected weight and weight loss of divided tablets/capsules were recorded. Results Five of eight study drugs failed, on splitting, to meet European Pharmacopoeia recommendations for tablet weight deviation from the expected weight of tablet/capsule halves with 10% deviating by more than 25%. There was a significant difference in splitting accuracy between nurses and laypersons (P = 0.027). Coated and unscored tablets were less accurately split than uncoated (P = 0.03 and 0.0019 for each half) and scored (0.0001 for both halves) tablets. Conclusion These findings have potential clinical implications on treatment outcome and the development of antimicrobial resistance. Investment by drug companies in a wider range of dosage units, particularly for narrow therapeutic index and critical dosage medicines, is strongly recommended. PMID:24702766
Narrow-headed garter snake (Thamnophis rufipunctatus)
Nowak, Erika M.
2006-01-01
The narrow-headed garter snake is a harmless, nonvenomous snake that is distinguished by its elongated, triangular-shaped head and the red or dark spots on its olive to tan body. Today, the narrow-headed garter snake is a species of special concern in the United States because of its decline over much of its historic range. Arizona's Oak Creek has historically contained the largest population of narrow-headed garter snakes in the United States. The U.S. Geological Survey (USGS) and the Arizona Game and Fish Department jointly funded research by USGS scientists in Oak Creek to shed light on the factors causing declining population numbers. The research resulted in better understanding of the snake's habitat needs, winter and summer range, and dietary habits. Based on the research findings, the U.S. Forest Service has developed recommendations that visitors and local residents can adopt to help slow the decline of the narrow-headed garter snake in Oak Creek.
Landscape heterogeneity-biodiversity relationship: effect of range size.
Katayama, Naoki; Amano, Tatsuya; Naoe, Shoji; Yamakita, Takehisa; Komatsu, Isamu; Takagawa, Shin-ichi; Sato, Naoto; Ueta, Mutsuyuki; Miyashita, Tadashi
2014-01-01
The importance of landscape heterogeneity to biodiversity may depend on the size of the geographic range of species, which in turn can reflect species traits (such as habitat generalization) and the effects of historical and contemporary land covers. We used nationwide bird survey data from Japan, where heterogeneous landscapes predominate, to test the hypothesis that wide-ranging species are positively associated with landscape heterogeneity in terms of species richness and abundance, whereas narrow-ranging species are positively associated with landscape homogeneity in the form of either open or forest habitats. We used simultaneous autoregressive models to explore the effects of climate, evapotranspiration, and landscape heterogeneity on the richness and abundance of breeding land-bird species. The richness of wide-ranging species and the total species richness were highest in heterogeneous landscapes, where many wide-ranging species showed the highest abundance. In contrast, the richness of narrow-ranging species was not highest in heterogeneous landscapes; most of those species were abundant in either open or forest landscapes. Moreover, in open landscapes, narrow-ranging species increased their species richness with decreasing temperature. These results indicate that heterogeneous landscapes are associated with rich bird diversity but that most narrow-ranging species prefer homogeneous landscapes--particularly open habitats in colder regions, where grasslands have historically predominated. There is a need to reassess the generality of the heterogeneity-biodiversity relationship, with attention to the characteristics of species assemblages determined by environments at large spatiotemporal scales.
Landscape Heterogeneity–Biodiversity Relationship: Effect of Range Size
Katayama, Naoki; Amano, Tatsuya; Naoe, Shoji; Yamakita, Takehisa; Komatsu, Isamu; Takagawa, Shin-ichi; Sato, Naoto; Ueta, Mutsuyuki; Miyashita, Tadashi
2014-01-01
The importance of landscape heterogeneity to biodiversity may depend on the size of the geographic range of species, which in turn can reflect species traits (such as habitat generalization) and the effects of historical and contemporary land covers. We used nationwide bird survey data from Japan, where heterogeneous landscapes predominate, to test the hypothesis that wide-ranging species are positively associated with landscape heterogeneity in terms of species richness and abundance, whereas narrow-ranging species are positively associated with landscape homogeneity in the form of either open or forest habitats. We used simultaneous autoregressive models to explore the effects of climate, evapotranspiration, and landscape heterogeneity on the richness and abundance of breeding land-bird species. The richness of wide-ranging species and the total species richness were highest in heterogeneous landscapes, where many wide-ranging species showed the highest abundance. In contrast, the richness of narrow-ranging species was not highest in heterogeneous landscapes; most of those species were abundant in either open or forest landscapes. Moreover, in open landscapes, narrow-ranging species increased their species richness with decreasing temperature. These results indicate that heterogeneous landscapes are associated with rich bird diversity but that most narrow-ranging species prefer homogeneous landscapes—particularly open habitats in colder regions, where grasslands have historically predominated. There is a need to reassess the generality of the heterogeneity-biodiversity relationship, with attention to the characteristics of species assemblages determined by environments at large spatiotemporal scales. PMID:24675969
Glaser, Adam K; Zhang, Rongxiao; Gladstone, David J; Pogue, Brian W
2014-07-21
Recent studies have proposed that light emitted by the Cherenkov effect may be used for a number of radiation therapy dosimetry applications. There is a correlation between the captured light and expected dose under certain conditions, yet discrepancies have also been observed and a complete examination of the theoretical differences has not been done. In this study, a fundamental comparison between the Cherenkov emission and absorbed dose was explored for x-ray photons, electrons, and protons using both a theoretical and Monte Carlo-based analysis. Based on the findings of where dose correlates with Cherenkov emission, it was concluded that for x-ray photons the light emission would be optimally suited for narrow beam stereotactic radiation therapy and surgery validation studies, for verification of dynamic intensity-modulated and volumetric modulated arc therapy treatment plans in water tanks, near monoenergetic sources (e.g., Co-60 and brachy therapy sources) and also for entrance and exit surface imaging dosimetry of both narrow and broad beams. For electron use, Cherenkov emission was found to be only suitable for surface dosimetry applications. Finally, for proton dosimetry, there exists a fundamental lack of Cherenkov emission at the Bragg peak, making the technique of little use, although post-irradiation detection of light emission from radioisotopes could prove to be useful.
ERIC Educational Resources Information Center
Inagaki, Shunji
1997-01-01
Investigated the acquisition of narrow-range rules governing the dative alternation by adult learners of English as a Second Language, native English speakers, and Japanese and Chinese speakers. Suggests that the Japanese and Chinese learners' acquisition of the dative alternation in English is governed by the properties of an equivalent structure…
Benz, Mark G; Benz, Matthew W; Birnbaum, Steven B; Chason, Eric; Sheldon, Brian W; McGuire, Dale
2014-08-01
This feasibility study has shown that improved spatial resolution and reduced radiation dose can be achieved in pediatric CT by narrowing the X-ray photon energy spectrum. This is done by placing a hafnium filter between the X-ray generator and a pediatric abdominal phantom. A CT system manufactured in 1999 that was in the process of being remanufactured was used as the platform for this study. This system had the advantage of easy access to the X-ray generator for modifications to change the X-ray photon energy spectrum; it also had the disadvantage of not employing the latest post-imaging noise reduction iterative reconstruction technology. Because we observed improvements after changing the X-ray photon energy spectrum, we recommend a future study combining this change with an optimized iterative reconstruction noise reduction technique.
Bronchoscopic phototherapy at comparable dose rates: Early results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pass, H.I.; Delaney, T.; Smith, P.D.
1989-05-01
Photodynamic therapy is a recently introduced treatment for surface malignancies. Since January 1987, 10 patients with endobronchial neoplasms have had bronchoscopic photodynamic therapy at similar dose rates (400 mW/cm) for total atelectasis (2), carinal narrowing with respiratory insufficiency (2), or partial obstruction without collapse (4). Two patients underwent photodynamic therapy as a preliminary to immunotherapy. Histologies included endobronchial metastases (colon, ovary, melanoma, and sarcoma, 1 each; and renal cell, 3) and primary lung cancer (3). The 2 patients with total atelectasis had complete reexpansion after photodynamic therapy, which permitted eventual sleeve lobectomy in 1. Carinal narrowing was ameliorated in themore » 2 patients seen with inspiratory stridor, thereby permitting hospital discharge. Endoscopically resected fragments after photodynamic therapy exhibited avascular necrosis. These data support further controlled studies of photodynamic therapy by thoracic surgical oncologists to define its limitations as well as to improve and expand its efficacy as a palliative or surgical adjuvant.« less
Ethylene Inhibits Aflatoxin Biosynthesis in Aspergillus parasiticus Grown on Peanuts
Gunterus, A.; Roze, L.V.; Beaudry, R.; Linz, J. E.
2007-01-01
The filamentous fungi Aspergillus parasiticus and A. flavus synthesize aflatoxins when they grow on a variety of susceptible food and feed crops. These mycotoxins are among the most carcinogenic naturally occurring compounds known and they pose significant health risks to humans and animals. We previously demonstrated that ethylene and CO2 act alone and together to reduce aflatoxin synthesis by A. parasiticus grown on laboratory media. To demonstrate the potential efficacy of treatment of stored seeds and grains with these gases, we tested ethylene and CO2 for ability to inhibit aflatoxin accumulation on Georgia Green peanuts stored for up to 5 days. We demonstrated an inverse relationship between A. parasiticus spore inoculum size and the level of toxin accumulation. We showed that ethylene inhibits aflatoxin synthesis in a dose-dependent manner on peanuts; CO2 also inhibits aflatoxin synthesis over a narrow dose range. Treatments had not discernable effect on mold growth. These observations support further exploration of this technology to reduce aflatoxin contamination of susceptible crops in the field and during storage. PMID:17418318
Chaswal, Vibha; Weldon, Michael; Gupta, Nilendu; Chakravarti, Arnab
2014-01-01
We present commissioning and comprehensive evaluation for ArcCHECK as a QA equipment for volumetric‐modulated arc therapy (VMAT), using the 6 MV photon beam with and without the flattening filter, and the SNC patient software (version 6.2). In addition to commissioning involving absolute dose calibration, array calibration, and PMMA density verification, ArcCHECK was evaluated for its response dependency on linac dose rate, instantaneous dose rate, radiation field size, beam angle, and couch insertion. Scatter dose characterization, consistency and symmetry of response, and dosimetry accuracy evaluation for fixed aperture arcs and clinical VMAT patient plans were also investigated. All the evaluation tests were performed with the central plug inserted and the homogeneous PMMA density value. Results of gamma analysis demonstrated an overall agreement between ArcCHECK‐measured and TPS‐calculated reference doses. The diode based field size dependency was found to be within 0.5% of the reference. The dose rate‐based dependency was well within 1% of the TPS reference, and the angular dependency was found to be ± 3% of the reference, as tested for BEV angles, for both beams. Dosimetry of fixed arcs, using both narrow and wide field widths, resulted in clinically acceptable global gamma passing rates on the 3%/3 mm level and 10% threshold. Dosimetry of narrow arcs showed an improvement over published literature. The clinical VMAT cases demonstrated high level of dosimetry accuracy in gamma passing rates. PACS numbers: 87.56.Fc, 87.55.kh, 87.55.Qr PMID:25207411
Space: The Final Frontier-Research Relevant to Mars.
Boice, John D
2017-04-01
A critically important gap in knowledge surrounds the health consequences of exposure to radiation received gradually over time. Much is known about the health effects of brief high-dose exposures, such as from the atomic bombings in Japan, but the concerns today focus on the frequent low-dose exposures received by members of the public, workers, and, as addressed in this paper, astronauts. Additional guidance is needed by the National Aeronautics and Space Administration (NASA) for planning long-term missions where the rate of radiation exposure is gradual over years and the cumulative amounts high. The direct study of low doses and low-dose rates is of immeasurable value in understanding the possible range of health effects from gradual exposures and in providing guidance for radiation protection, not only of workers and the public but also astronauts. The ongoing Million Person Study (MPS) is 10 times larger than the study of the Japanese atomic bomb survivors of 86,000 survivors with estimated doses. The number of workers with >100 mSv career dose is substantially greater. The large study size, broad range of doses, and long follow-up indicate substantial statistical ability to quantify the risk of exposures that are received gradually over time. The study consists of 360,000 U.S. Department of Energy workers from the Manhattan Project; 150,000 nuclear utility workers from the inception of the nuclear age; 115,000 atomic veterans who participated in above-ground atmospheric tests at the Nevada Test Site and the Bikini and Enewetak Atolls and Johnston Island in the Pacific Proving Grounds (PPG); 250,000 radiologists and medical workers; and 130,000 industrial radiographers. NASA uses an individual risk-based system for radiation protection in contrast to the system of dose limits for occupational exposures used by terrestrial-based organizations. The permissible career exposure limit set by NASA for each astronaut is a 3% risk of exposure-induced death (REID) from cancer at a 95% confidence level to account for uncertainties in risk projections. The large size of the MPS will reduce the uncertainty in the risk estimates, narrowing the 95% confidence interval, and thus allow more time in space for astronauts. Further differences between men and women in their response to radiation can be more fully examined, and non-cancer outcomes, such as neurological disorders and cardiovascular disease, can be evaluated in a way not hitherto possible.
EMBOLIZATION OF DOG PROSTATES WITH YTTRIUM-90 MICROSPHERES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greene, W.M.
1963-10-01
Experiments exploring means for the protection of adjacent normal tissue while delivering a destructive dose of radiation to malignant tissue were conducted. By injection of radioactive ceramic spheres or particles, too large to pass through capillaries or arteriovenous shunts, relatively high doses of radiation can be distributed homogeneously to a circumscribed area. Attempts were made to determine the uniformity of distribution and the radiation effect of varying doses of spheres injected into the arterial supply of the dog prostate. Nonradioactive and radioactive ceramic microspheres of 60 mu dia were used since this size exceeds the diameter of capillaries and arteriovenousmore » shunts. Yttrium-90 microspheres of varying radioactivity were used. Doses injected into right and left hypogastric arteries varied from 0.69 to 28.4 mc/side (92-1260 mc/ g prostate). Homogeneous distribution of radioactivity within the prostate was demonstrated by autoradiography. Distribution to some other organs (rectum, penis, and bladder) occurred because arterial supply to these structures was not isolated and occluded. The amount of radioactivity found in the lungs suggested more venous drainage in some cases than seemed apparent, and because of the infarctions of pelvic organs may have leaked radioactive spheres into the venous circuit. In 6 of the 8 dogs which died prematurely (2 to 7 days after surgery) obvious infarction of the prostate and in some other pelvic structures had occurred. That the radioactivity contributed to the infarction is suggested by the results in the dogs which received large doses of radioactivity (18.9 and 28.4 mc per side) in minimal amounts of spheres (100to 150 mg per side). The intensely concentrated radioactivity within the arteriolar lumens may have caused vasculitis and subsequent thrombosis. Although homogeneous destruction of the prostate gland occurred, the effect of a given dose ranged unpredictably through three groups: no apparent effect at all, destruction of the prostate, and early death with infarction of the prostate and other pelvic organs. It was concluded that with the present technique the range between the dose of radioactivity which caused no obvious response and the dose which is related to acute death is too narrow to allow reasonably predictable results, but that further refinement of technique might increase control over tissue destruction.« less
Würl, M; Englbrecht, F; Parodi, K; Hillbrand, M
2016-01-21
Due to the low-dose envelope of scanned proton beams, the dose output depends on the size of the irradiated field or volume. While this field size dependence has already been extensively investigated by measurements and Monte Carlo (MC) simulations for single pencil beams or monoenergetic fields, reports on the relevance of this effect for analytical dose calculation models are limited. Previous studies on this topic only exist for specific beamline designs. However, the amount of large-angle scattered primary and long-range secondary particles and thus the relevance of the low-dose envelope can considerably be influenced by the particular design of the treatment nozzle. In this work, we therefore addressed the field size dependence of the dose output at the commercially available ProBeam(®) beamline, which is being built in several facilities worldwide. We compared treatment planning dose calculations with ionization chamber (IC) measurements and MC simulations, using an experimentally validated FLUKA MC model of the scanning beamline. To this aim, monoenergetic square fields of three energies, as well as spherical target volumes were studied, including the investigation on the influence of the lateral spot spacing on the field size dependence. For the spherical target volumes, MC as well as analytical dose calculation were found in excellent agreement with the measurements in the center of the spread-out Bragg peak. In the plateau region, the treatment planning system (TPS) tended to overestimate the dose compared to MC calculations and IC measurements by up to almost 5% for the smallest investigated sphere and for small monoenergetic square fields. Narrower spot spacing slightly enhanced the field size dependence of the dose output. The deviations in the plateau dose were found to go in the clinically safe direction, i.e. the actual deposited dose outside the target was found to be lower than predicted by the TPS. Thus, the moderate overestimation of dose to normal tissue by the TPS is likely to result in no severe consequences in clinical cases, even for the most critical cases of small target volumes.
Motivation Matters: Differing Effects of Pre-Goal and Post-Goal Emotions on Attention and Memory
Kaplan, Robin L.; Van Damme, Ilse; Levine, Linda J.
2012-01-01
People often show enhanced memory for information that is central to emotional events and impaired memory for peripheral details. The intensity of arousal elicited by an emotional event is commonly held to be the mechanism underlying memory narrowing, with the implication that all sources of emotional arousal should have comparable effects. Discrete emotions differ in their effects on memory, however, with some emotions broadening rather than narrowing the range of information attended to and remembered. Thus, features of emotion other than arousal appear to play a critical role in memory narrowing. We review theory and research on emotional memory narrowing and argue that motivation matters. Recent evidence suggests that emotions experienced prior to goal attainment or loss lead to memory narrowing whereas emotions experienced after goal attainment or loss broaden the range of information encoded in memory. The motivational component of emotion is an important but understudied feature that can help to clarify the conditions under which emotions enhance and impair attention and memory. PMID:23162490
Motivation matters: differing effects of pre-goal and post-goal emotions on attention and memory.
Kaplan, Robin L; Van Damme, Ilse; Levine, Linda J
2012-01-01
People often show enhanced memory for information that is central to emotional events and impaired memory for peripheral details. The intensity of arousal elicited by an emotional event is commonly held to be the mechanism underlying memory narrowing, with the implication that all sources of emotional arousal should have comparable effects. Discrete emotions differ in their effects on memory, however, with some emotions broadening rather than narrowing the range of information attended to and remembered. Thus, features of emotion other than arousal appear to play a critical role in memory narrowing. We review theory and research on emotional memory narrowing and argue that motivation matters. Recent evidence suggests that emotions experienced prior to goal attainment or loss lead to memory narrowing whereas emotions experienced after goal attainment or loss broaden the range of information encoded in memory. The motivational component of emotion is an important but understudied feature that can help to clarify the conditions under which emotions enhance and impair attention and memory.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siauw, Timmy; Cunha, Adam; Berenson, Dmitry
Purpose: In this study, the authors introduce skew line needle configurations for high dose rate (HDR) brachytherapy and needle planning by integer program (NPIP), a computational method for generating these configurations. NPIP generates needle configurations that are specific to the anatomy of the patient, avoid critical structures near the penile bulb and other healthy structures, and avoid needle collisions inside the body. Methods: NPIP consisted of three major components: a method for generating a set of candidate needles, a needle selection component that chose a candidate needle subset to be inserted, and a dose planner for verifying that the finalmore » needle configuration could meet dose objectives. NPIP was used to compute needle configurations for prostate cancer data sets from patients previously treated at our clinic. NPIP took two user-parameters: a number of candidate needles, and needle coverage radius, {delta}. The candidate needle set consisted of 5000 needles, and a range of {delta} values was used to compute different needle configurations for each patient. Dose plans were computed for each needle configuration. The number of needles generated and dosimetry were analyzed and compared to the physician implant. Results: NPIP computed at least one needle configuration for every patient that met dose objectives, avoided healthy structures and needle collisions, and used as many or fewer needles than standard practice. These needle configurations corresponded to a narrow range of {delta} values, which could be used as default values if this system is used in practice. The average end-to-end runtime for this implementation of NPIP was 286 s, but there was a wide variation from case to case. Conclusions: The authors have shown that NPIP can automatically generate skew line needle configurations with the aforementioned properties, and that given the correct input parameters, NPIP can generate needle configurations which meet dose objectives and use as many or fewer needles than the current HDR brachytherapy workflow. Combined with robot assisted brachytherapy, this system has the potential to reduce side effects associated with treatment. A physical trial should be done to test the implant feasibility of NPIP needle configurations.« less
Assessment of the actual light dose in photodynamic therapy.
Schaberle, Fabio A
2018-06-09
Photodynamic therapy (PDT) initiates with the absorption of light, which depends on the spectral overlap between the light source emission and the photosensitizer absorption, resulting in the number of photons absorbed, the key parameter starting PDT processes. Most papers report light doses regardless if the light is only partially absorbed or shifted relatively to the absorption peak, misleading the actual light dose value and not allowing quantitative comparisons between photosensitizers and light sources. In this manuscript a method is presented to calculate the actual light dose delivered by any light source for a given photosensitizer. This method allows comparing light doses delivered for any combination of light source (broad or narrow band or daylight) and photosensitizer. Copyright © 2018. Published by Elsevier B.V.
Cyclopamine-induced synophthalmia in sheep: defining a critical window and toxicokinetic evaluation.
Welch, K D; Panter, K E; Lee, S T; Gardner, D R; Stegelmeier, B L; Cook, D
2009-07-01
Cyclopamine, a steroidal alkaloid, from the plant Veratrum californicum is teratogenic, causing a range of different birth defects. The critical window for cyclopamine-induced synophthalmia formation has been reported to be gestational day (GD) 14. The objectives of this study were to better describe cyclopamine-induced craniofacial deformities, to better define the window of susceptibility to synophthalmia formation, and to characterize cyclopamine toxicokinetics in sheep. Ewes were dosed i.v. with purified cyclopamine for toxicokinetic analysis. Another four groups of ewes were dosed orally twice daily with 0.88 g/kg of V. californicum on GD 13, 14 or 15 or consecutively on GD days 13-15. Pregnancy and pre-partum fetal malformations were determined by ultrasound imaging on GD 60. At parturition lambs were assessed for gross malformations. The elimination half-life of cyclopamine in ewes was determined to be 1.1 +/- 0.1 h. The rapid clearance of cyclopamine indicates that ingestion of V. californicum must occur during a very narrow window for synophthalmia formation to occur. Ewes dosed with V. californicum on GD 13 or 14 had lambs with various craniofacial malformations including cyclopia, maxillary dysplasia and mandibular micrognathia. Ewes dosed on GD 15 delivered normal lambs. Ewes dosed consecutively on GD 13-15 were not pregnant at GD 60 and Veratrum-induced embryonic death was assumed to be the cause. Interestingly, lambs with cyclopia were smaller, under-developed and appeared premature even though their twin appeared fully developed. Initial evaluations suggest this was due to placental dysplasia. 2009 by John Wiley & Sons, Ltd.
A Characterization of the Radiation from a Rod-Pinch Diode
NASA Astrophysics Data System (ADS)
Swanekamp, Stephen B.; Allen, Raymond J.; Hinshelwood, David D.; Mosher, David; Schumer, Joseph W.
2002-12-01
Coupled PIC-Monte-Carlo simulations of the electron-flow and radiation production in a rod-pinch diode show that multiple scatterings in the rod produce incident electron energies that ranging from zero to slightly higher than the applied voltage. It is speculated that those electrons that gain energy do so by remaining in phase with a rapidly varying electric field near the tip of the rod. The simulations also show that multiple passes in the rod produce a wide spread in incident electron angles. For diode voltages of V=2 MV, the angular distribution of electrons incident on the rod is broad and peaked near 90° to the axis of the rod with a larger fraction of electrons striking the rod at angles less than 90°. The electron angular distribution for V=4 MV is narrower and peaked at 105° with a larger fraction of electrons incident on the rod with angles greater than 90°. The photon distributions are peaked along the direction of the high-energy electrons. For V=2 MV the dose filtered through 21/4-cm thick Plexiglas is peaked at 90° and is 1.8 times higher than the forward-directed [0°] dose. For V=4 MV the dose filtered through 21/4-cm thick Plexiglas is peaked at 120° and is 2.3 times higher than the forward-directed dose. Similar angular variation of the dose has been observed on the 4-MV Asterix accelerator [2] and on 1-2 MV accelerators at the Atomic Weapons Establishment [8].
Chandra, Navin; Singh, Deepesh Kumar; Sharma, Meenakshi; Upadhyay, Ravi Kant; Amritphale, S S; Sanghi, S K
2010-02-15
For the first time, single reverse microemulsion-assisted direct precipitation route has been successfully used to synthesize tetragonal zirconia nanoparticles in narrow size range. The synthesized powder was characterized using FT-IR, XRD and HRTEM techniques. The zirconia nanoparticles obtained were spherical in shape and has narrow particle size distribution in the range of 13-31nm and crystallite size in the range of 13-23nm. Copyright 2009 Elsevier Inc. All rights reserved.
Winter Precipitation Efficiency of Mountain Ranges in the Colorado Rockies Under Climate Change
NASA Astrophysics Data System (ADS)
Eidhammer, Trude; Grubišić, Vanda; Rasmussen, Roy; Ikdea, Kyoko
2018-03-01
Orographic precipitation depends on the environmental conditions and the barrier shape. In this study we examine the sensitivity of the precipitation efficiency (i.e., drying ratio (DR)), defined as the ratio of precipitation to incoming water flux, to mountain shape, temperature, stability, and horizontal velocity of the incoming air mass. Furthermore, we explore how the DR of Colorado mountain ranges might change under warmer and moister conditions in the future. For given environmental conditions, we find the DR to be primarily dependent on the upwind slope for mountain ranges wider than about 70 km and on both the slope and width for narrower ranges. Temperature is found to exert an influence on the DR for all Colorado mountain ranges, with DR decreasing with increasing temperature, under both the current and future climate conditions. The decrease of DR with temperature under warmer climate was found to be stronger for wider mountains than the narrower ones. We attribute this asymmetry to the sensitivity of DR to reduced horizontal velocity under warmer conditions. Specifically, while DR for wider mountains shows no sensitivity to changes in horizontal velocity, the DR for narrow ranges increases as the horizontal velocity decreases and more time is provided for precipitation to form. Thus, for narrower ranges, the horizontal velocity appears to offset the temperature effect slightly. The percentagewise decrease of DR for all examined mountain ranges is about 4%K-1. In comparison, the increase in precipitation is about 6%K-1 while the vapor flux increase is about 9%K-1.
Eckmann, Karen; Michaud, Laura B; Rivera, Edgardo; Madden, Timothy L; Esparza-Guerra, Laura; Kawedia, Jitesh; Booser, Daniel J; Green, Marjorie C; Hortobagyi, Gabriel N; Valero, Vicente
2014-04-01
Limited clinical data are available regarding the safety of docetaxel in metastatic breast cancer patients with liver dysfunction. Eligible patients had breast cancer with impaired liver function secondary to hepatic metastases and were candidates for docetaxel therapy. They were assigned to one of five groups on the basis of total bilirubin, alanine aminotransferase, aspartate aminotransferase, and alkaline phosphatase levels. All other causes of liver dysfunction were excluded, and bile duct obstruction was corrected, if possible, prior to study entry. Patients received docetaxel every three weeks. The chemotherapy dose was chosen on the basis of the patient's level of hepatic dysfunction and escalated as tolerated. The primary outcome of this study was safety. The secondary outcomes were pharmacokinetic data and efficacy in terms of time to disease progression. Twenty-three patients were enrolled. No unexpected toxicities occurred. Grade 3/4 fatigue (65%), neutropenia (30%), myalgias (26%), neutropenic fever (26%), vomiting (9%), and rash (9%) were the most common serious adverse events. The median time to progression was three months (range 1-18 months). Pharmacokinetic results indicated that patients with more severe hepatic dysfunction may have been underdosed based on our conservative dosing strategy. Docetaxel can be administered to patients with metastatic breast cancer and liver dysfunction after dose attenuation. However, because of a narrow therapeutic index in this clinical setting, therapy should be closely monitored with subsequent dose escalation when possible.
LeToquin, Ronan P; Tong, Tao; Glass, Robert C
2014-12-30
Light emitting devices include a light emitting diode ("LED") and a recipient luminophoric medium that is configured to down-convert at least some of the light emitted by the LED. In some embodiments, the recipient luminophoric medium includes a first broad-spectrum luminescent material and a narrow-spectrum luminescent material. The broad-spectrum luminescent material may down-convert radiation emitted by the LED to radiation having a peak wavelength in the red color range. The narrow-spectrum luminescent material may also down-convert radiation emitted by the LED into the cyan, green or red color range.
Freitas, Kelen; Carroll, F Ivy; Negus, S Stevens
2016-02-01
Intracranial self-stimulation (ICSS) is one type of preclinical procedure for research on pharmacological mechanisms that mediate abuse potential of drugs acting at various targets, including nicotinic acetylcholine receptors (nAChRs). This study compared effects of the nonselective nAChR agonist nicotine (0.032-1.0 mg/kg) and the α4β2-selective nAChR agonist 5-I-A-85380 (0.01-1.0 mg/kg) on ICSS in male Sprague-Dawley rats. Rats were implanted with electrodes targeting the medial forebrain bundle at the level of the lateral hypothalamus and trained to respond under a fixed-ratio 1 schedule for a range of brain stimulation frequencies (158-56 Hz). A broad range of 5-I-A-85380 doses produced an abuse-related increase (or "facilitation") of low ICSS rates maintained by low brain-stimulation frequencies, and this effect was blocked by both the nonselective nAChR antagonist mecamylamine and the selective α4β2 antagonist dihyrdo-β-erythroidine (DHβE). Conversely, nicotine produced weaker ICSS facilitation across a narrower range of doses, and higher nicotine doses decreased high rates of ICSS maintained by high brain-stimulation frequencies. The rate-decreasing effects of a high nicotine dose were blocked by mecamylamine but not DHβE. Chronic nicotine treatment produced selective tolerance to rate-decreasing effects of nicotine but did not alter ICSS rate-increasing effects of nicotine. These results suggest that α4β2 receptors are sufficient to mediate abuse-related rate-increasing effects of nAChR agonists in this ICSS procedure. Conversely, nicotine effects at non-α4β2 nAChRs appear to oppose and limit abuse-related effects mediated by α4β2 receptors, although tolerance can develop to these non-α4β2 effects. Selective α4β2 agonists may have higher abuse potential than nicotine. PsycINFO Database Record (c) 2016 APA, all rights reserved.
Steen, V M; Tysnes, O B; Holmsen, H
1988-01-01
We have studied synergism between adrenaline (epinephrine) and low concentrations of thrombin in gel-filtered human platelets prelabelled with [32P]Pi. Suspensions of platelets, which did not contain added fibrinogen, were incubated at 37 degrees C to measure changes in the levels of 32P-labelled phosphatidylinositol 4,5-bisphosphate (PIP2), phosphatidylinositol 4-phosphate (PIP) and phosphatidate (PA), aggregation and dense-granule secretion after stimulation. Adrenaline alone (3.5-4.0 microM) did not cause a change in any parameter (phosphoinositide metabolism, aggregation and dense-granule secretion), but markedly enhanced the thrombin-induced responses over a narrow range of thrombin concentrations (0.03-0.08 units/ml). The thrombin-induced hydrolysis of inositol phospholipids by phospholipase C, which was measured as the formation of [32P]PA, was potentiated by adrenaline, as was the increase in the levels of [32P]PIP2 and [32P]PIP. The presence of adrenaline caused a shift to the left for the thrombin-induced changes in the phosphoinositide metabolism, without affecting the maximal levels of 32P-labelled compounds obtained. A similar shift by adrenaline in the dose-response relationship was previously demonstrated for thrombin-induced aggregation and dense-granule secretion. Also, the narrow range of concentrations of thrombin over which adrenaline potentiates thrombin-induced platelet responses is the same for changes in phosphoinositide metabolism and physiological responses (aggregation and dense-granule secretion). Our observations clearly indicate that adrenaline directly or indirectly influences thrombin-induced changes in phosphoinositide metabolism. PMID:2845924
Comparative analysis of Beggiatoa from hypersaline and marine environments.
de Albuquerque, Julia Peixoto; Keim, Carolina Neumann; Lins, Ulysses
2010-07-01
The main criterion to classify a microorganism as belonging to the genus Beggiatoa is its morphology. All multicellular, colorless, gliding bacterial filaments containing sulfur globules described so far belong to this genus. At the ultrastructural level, they show also a very complex cell envelope structure. Here we describe uncultured vacuolated and non-vacuolated bacteria from two different environments showing all characteristics necessary to assign a bacterium to the genus Beggiatoa. We also intended to investigate whether narrow and vacuolate Beggiatoa do differ morphologically as much as they do phylogenetically. Both large, vacuolated trichomes and narrow filaments devoid of vacuoles were observed. We confirmed the identity of the narrow filaments by 16S rRNA phylogenetic analysis. The diameters of the trichomes ranged from 2.4 to 34 microm, and their lengths ranged from 10 microm to over 30 mm. Narrow trichomes moved by gliding at 3.0 microm/s; large filaments moved at 1.5 microm/s. Periplasmic sulfur inclusions were observed in both types of filaments, whereas phosphorus-rich bodies were found only in narrow trichomes. On the other hand, nitrate vacuoles were observed only in large trichomes. Ultra-thin section transmission electron microscopy showed differences between the cell ultrastructure of narrow (non-vacuolated) and large (vacuolated) Beggiatoa. We observed that cell envelopes from narrow Beggiatoa consist of five layers, whereas cell envelopes from large trichomes contain four layers. Copyright 2010 Elsevier Ltd. All rights reserved.
Three-Body Recombination near a Narrow Feshbach Resonance in
NASA Astrophysics Data System (ADS)
Li, Jiaming; Liu, Ji; Luo, Le; Gao, Bo
2018-05-01
We experimentally measure and theoretically analyze the three-atom recombination rate, L3, around a narrow s -wave magnetic Feshbach resonance of
A technique for production of nanocrystalline cellulose with a narrow size distribution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bai, Wen; Holbery, James D.; Li, Kaichang
2009-02-01
Nanocrystalline cellulose (NCC) was prepared by sulfuric acid hydrolysis of microcrystalline cellulose. A differential centrifugation technique was studied to obtain NCC whiskers with a narrow size distribution. It was shown that the volume of NCC in different fractions had an inverse relationship with relative centrifugal force (RCF). The length of NCC whiskers was also fractionized by differential RCF. The aspect ratio of NCC in different fractions had a relatively narrow range. This technique provides an easy way of producing NCC whiskers with a narrow size distribution.
1986-01-24
P-29508BW Range: 1.12 million kilometers (690,000 miles) This clear-filter view of the Uranian rings delta, gamma, eta, beta and alpha (from top) was taken with Voyager 2's narrow-angle camera and clearly illustrates the broad outer component and narrow inner component of the eta ring, which orbits Uranus at a radius of some 47,000 km (29,000 mi). The broad component is considerably more transparent than the dense, narrow inner eta component, as well as the other narrow rings shown. Resolution here is about 10 km (6 mi).
Kono, Momoko; Hasegawa, Jumpei; Ogawa, Hina; Yoshikawa, Kanae; Ishiwatari, Ayumi; Wakai, Sachiko; Tanabe, Kazunari; Shirakawa, Hiroki
2018-05-01
Tacrolimus is the most commonly used immunosuppressant. Because of its narrow therapeutic range, it is necessary to frequently monitor its concentration. We report the case of a 25-year-old man who underwent kidney transplantation whose tacrolimus concentrations, as measured by an affinity column-mediated immunoassay, were falsely elevated. As we reduced the dose of tacrolimus, the recipient developed T cell-mediated rejection. Using the same blood samples, an enzyme-multiplied immunoassay technique showed that the patient's levels of tacrolimus were extremely low. A further examination indicated that the false increase in the tacrolimus concentration was likely due to an unknown interfering substance. We administered methylprednisolone and antithymocyte-globulin. The patient's serum creatinine level decreased and remained stable after these treatments.
Anticoagulant management in the cardiovascular setting.
Verheugt, Freek W A
2012-02-01
Vitamin K antagonists have been used as oral anticoagulants (OACs) for over five decades, yet their use in real-world practice is problematic primarily because of their narrow therapeutic window, exacerbated by extensive food and drug interactions, necessitating regular coagulation monitoring and dose adjustment. Around half of patients receiving warfarin are within the therapeutic range, exposing them to the dangers of under-anticoagulation (i.e. thrombosis formation) or over-anticoagulation (i.e. bleeding). A new generation of OACs with improved pharmacology promises to revolutionize antithrombotic management. Rivaroxaban, apixaban (both oral direct Factor Xa inhibitors) and dabigatran (a direct thrombin inhibitor) all exhibit predictable anticoagulant responses and few drug-drug interactions and do not require routine coagulation monitoring. © 2011 The Author Fundamental and Clinical Pharmacology © 2011 Société Française de Pharmacologie et de Thérapeutique.
Toxicity of nano- and micro-sized ZnO particles in human lung epithelial cells
NASA Astrophysics Data System (ADS)
Lin, Weisheng; Xu, Yi; Huang, Chuan-Chin; Ma, Yinfa; Shannon, Katie B.; Chen, Da-Ren; Huang, Yue-Wern
2009-01-01
This is the first comprehensive study to evaluate the cytotoxicity, biochemical mechanisms of toxicity, and oxidative DNA damage caused by exposing human bronchoalveolar carcinoma-derived cells (A549) to 70 and 420 nm ZnO particles. Particles of either size significantly reduced cell viability in a dose- and time-dependent manner within a rather narrow dosage range. Particle mass-based dosimetry and particle-specific surface area-based dosimetry yielded two distinct patterns of cytotoxicity in both 70 and 420 nm ZnO particles. Elevated levels of reactive oxygen species (ROS) resulted in intracellular oxidative stress, lipid peroxidation, cell membrane leakage, and oxidative DNA damage. The protective effect of N-acetylcysteine on ZnO-induced cytotoxicity further implicated oxidative stress in the cytotoxicity. Free Zn2+ and metal impurities were not major contributors of ROS induction as indicated by limited free Zn2+ cytotoxicity, extent of Zn2+ dissociation in the cell culture medium, and inductively-coupled plasma-mass spectrometry metal analysis. We conclude that (1) exposure to both sizes of ZnO particles leads to dose- and time-dependent cytotoxicity reflected in oxidative stress, lipid peroxidation, cell membrane damage, and oxidative DNA damage, (2) ZnO particles exhibit a much steeper dose-response pattern unseen in other metal oxides, and (3) neither free Zn2+ nor metal impurity in the ZnO particle samples is the cause of cytotoxicity.
Animal investigation program, 1981 annual report: Nevada Test Site and vicinity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, D.D.; Giles, K.R.
1982-01-01
Data are presented from the radioanalysis of tissues, collected from animals that resided on or near the Nevada Test Site (NTS). Other than naturally occurring potassium-40, cesium-137 was the only gamma-emitting radionuclide frequently detected and was within a narrow range of activity. For example, 12 of 14 cattle muscle samples contained 15 to 65 pCi of cesium-137 per kilogram. Strontium-90 and plutonium-238 or -239 tissue concentrations were similar to those of recent years. Nanocurie levels of tritium were found in tissue from two deer that drank contaminated water draining from the tunnel test areas. Annual dose estimates to man weremore » calculated based on the daily consumption of 0.5 kg of tissue with peak radionuclide levels. The highest postulated dose was 45 millirems to the whole body from ingestion of deer muscle that drank from the tritium contaminated waters. This dose is about 9% of the radiation protection guide. Movement of deer on the NTS is discussed. In general, deer from Pahute Mesa winter in the Timber Mt. area with some movement off the NTS, while deer from Rainier Mesa winter in the Shoshone Mt. area. The sudden death of an offsite goat kid was investigated and death was attributed to enterotoxemia. No gross or microscopic lesions in necropsied animals were found that could be attributed to the effect of ionizing radiation.« less
Mould, Diane R; Dubinsky, Marla C
2015-03-01
Many marketed drugs exhibit high variability in exposure and response. While these drugs are efficacious in their approved indications, finding appropriate dose regimens for individual patients is not straightforward. Similar dose adjustment problems are also seen with drugs that have a complex relationship between exposure and response and/or a narrow therapeutic window. This is particularly true for monoclonal antibodies, where prolonged dosing at a sub-therapeutic dose can also elicit anti-drug antibodies which will further compromise safety and efficacy. Thus, finding appropriate doses quickly would represent a substantial improvement in healthcare. Dashboard systems, which are decision-support tools, offer an improved, convenient means of tailoring treatment for individual patients. This article reviews the clinical need for this approach, particularly with monoclonal antibodies, the design, development, and testing of such systems, and the likely benefits of dashboard systems in clinical practice. We focus on infliximab for reference. © 2015, The American College of Clinical Pharmacology.
The effect of mixing on fermentation of primary solids, glycerol, and biodiesel waste.
Ghasemi, Marzieh; Randall, Andrew A
2018-03-01
In this study, the effect of mixing on volatile fatty acid (VFA) production and composition was investigated through running five identical bench-scale reactors that were filled with primary solid and dosed with either pure glycerol or biodiesel waste. Experimental results revealed that there was an inverse correlation between the mixing intensity and the VFA production. The total VFA production in the un-mixed reactor was 9,787 ± 3,601 mg COD/L, whereas in the reactor mixed at 100 rpm this dropped to 3,927 ± 1,175 mg COD/L, while both types of reactor were dosed with pure glycerol at the beginning of each cycle to reach the initial concentration of 1,000 mg/L (1,217 mg COD/L). Propionic acid was the dominant VFA in all the reactors except the reactor mixed at 30 rpm. It is hypothesized that low mixing facilitated hydrogen transfer between obligate hydrogen producing acetogens (OHPA) and hydrogen consuming acidogens in these non-methanogenic reactors. Also, in a narrower range of mixing (0 or 7 rpm), the total VFA production in biodiesel waste-fed reactors was considerably higher than that of pure glycerol-fed reactors.
Quantitative evaluation of potential irradiation geometries for carbon-ion beam grid therapy.
Tsubouchi, Toshiro; Henry, Thomas; Ureba, Ana; Valdman, Alexander; Bassler, Niels; Siegbahn, Albert
2018-03-01
Radiotherapy using grids containing cm-wide beam elements has been carried out sporadically for more than a century. During the past two decades, preclinical research on radiotherapy with grids containing small beam elements, 25 μm-0.7 mm wide, has been performed. Grid therapy with larger beam elements is technically easier to implement, but the normal tissue tolerance to the treatment is decreasing. In this work, a new approach in grid therapy, based on irradiations with grids containing narrow carbon-ion beam elements was evaluated dosimetrically. The aim formulated for the suggested treatment was to obtain a uniform target dose combined with well-defined grids in the irradiated normal tissue. The gain, obtained by crossfiring the carbon-ion beam grids over a simulated target volume, was quantitatively evaluated. The dose distributions produced by narrow rectangular carbon-ion beams in a water phantom were simulated with the PHITS Monte Carlo code. The beam-element height was set to 2.0 cm in the simulations, while the widths varied from 0.5 to 10.0 mm. A spread-out Bragg peak (SOBP) was then created for each beam element in the grid, to cover the target volume with dose in the depth direction. The dose distributions produced by the beam-grid irradiations were thereafter constructed by adding the dose profiles simulated for single beam elements. The variation of the valley-to-peak dose ratio (VPDR) with depth in water was thereafter evaluated. The separation of the beam elements inside the grids were determined for different irradiation geometries with a selection criterion. The simulated carbon-ion beams remained narrow down to the depths of the Bragg peaks. With the formulated selection criterion, a beam-element separation which was close to the beam-element width was found optimal for grids containing 3.0-mm-wide beam elements, while a separation which was considerably larger than the beam-element width was found advantageous for grids containing 0.5-mm-wide beam elements. With the single-grid irradiation setup, the VPDRs were close to 1.0 already at a distance of several cm from the target. The valley doses given to the normal tissue at 0.5 cm distance from the target volume could be limited to less than 10% of the mean target dose if a crossfiring setup with four interlaced grids was used. The dose distributions produced by grids containing 0.5- and 3.0-mm wide beam elements had characteristics which could be useful for grid therapy. Grids containing mm-wide carbon-ion beam elements could be advantageous due to the technical ease with which these beams can be produced and delivered, despite the reduced threshold doses observed for early and late responding normal tissue for beams of millimeter width, compared to submillimetric beams. The treatment simulations showed that nearly homogeneous dose distributions could be created inside the target volumes, combined with low valley doses in the normal tissue located close to the target volume, if the carbon-ion beam grids were crossfired in an interlaced manner with optimally selected beam-element separations. The formulated selection criterion was found useful for the quantitative evaluation of the dose distributions produced by the different irradiation setups. © 2018 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Sheth, Seema N; Angert, Amy L
2014-10-01
The geographic ranges of closely related species can vary dramatically, yet we do not fully grasp the mechanisms underlying such variation. The niche breadth hypothesis posits that species that have evolved broad environmental tolerances can achieve larger geographic ranges than species with narrow environmental tolerances. In turn, plasticity and genetic variation in ecologically important traits and adaptation to environmentally variable areas can facilitate the evolution of broad environmental tolerance. We used five pairs of western North American monkeyflowers to experimentally test these ideas by quantifying performance across eight temperature regimes. In four species pairs, species with broader thermal tolerances had larger geographic ranges, supporting the niche breadth hypothesis. As predicted, species with broader thermal tolerances also had more within-population genetic variation in thermal reaction norms and experienced greater thermal variation across their geographic ranges than species with narrow thermal tolerances. Species with narrow thermal tolerance may be particularly vulnerable to changing climatic conditions due to lack of plasticity and insufficient genetic variation to respond to novel selection pressures. Conversely, species experiencing high variation in temperature across their ranges may be buffered against extinction due to climatic changes because they have evolved tolerance to a broad range of temperatures. © 2014 The Author(s). Evolution © 2014 The Society for the Study of Evolution.
Vilches, M; García-Pareja, S; Guerrero, R; Anguiano, M; Lallena, A M
2009-09-01
In this work, recent results from experiments and simulations (with EGSnrc) performed by Ross et al. [Med. Phys. 35, 4121-4131 (2008)] on electron scattering by foils of different materials and thicknesses are compared to those obtained using several Monte Carlo codes. Three codes have been used: GEANT (version 3.21), Geant4 (version 9.1, patch03), and PENELOPE (version 2006). In the case of PENELOPE, mixed and fully detailed simulations have been carried out. Transverse dose distributions in air have been obtained in order to compare with measurements. The detailed PENELOPE simulations show excellent agreement with experiment. The calculations performed with GEANT and PENELOPE (mixed) agree with experiment within 3% except for the Be foil. In the case of Geant4, the distributions are 5% narrower compared to the experimental ones, though the agreement is very good for the Be foil. Transverse dose distribution in water obtained with PENELOPE (mixed) is 4% wider than those calculated by Ross et al. using EGSnrc and is 1% narrower than the transverse dose distributions in air, as considered in the experiment. All the codes give a reasonable agreement (within 5%) with the experimental results for all the material and thicknesses studied.
NASA Astrophysics Data System (ADS)
Mon, K. K.
2018-05-01
In this paper, the virial series expansion and constant pressure Monte Carlo method are used to study the longitudinal pressure equation of state for hard spheres in narrow cylindrical pores. We invoke dimensional reduction and map the model into an effective one-dimensional fluid model with interacting internal degrees of freedom. The one-dimensional model is extensive. The Euler relation holds, and longitudinal pressure can be probed with the standard virial series expansion method. Virial coefficients B2 and B3 were obtained analytically, and numerical quadrature was used for B4. A range of narrow pore widths (2 Rp) , Rp<(√{3 }+2 ) /4 =0.9330 ... (in units of the hard sphere diameter) was used, corresponding to fluids in the important single-file formations. We have also computed the virial pressure series coefficients B2', B3', and B4' to compare a truncated virial pressure series equation of state with accurate constant pressure Monte Carlo data. We find very good agreement for a wide range of pressures for narrow pores. These results contribute toward increasing the rather limited understanding of virial coefficients and the equation of state of hard sphere fluids in narrow cylindrical pores.
Potency of a tau fibrillization inhibitor is influenced by its aggregation state
Congdon, Erin E.; Necula, Mihaela; Blackstone, Robert D.; Kuret, Jeff
2007-01-01
Tau fibrillization is a potential therapeutic target for Alzheimer’s and other neurodegenerative diseases. Several small molecule inhibitors of tau aggregation have been developed for this purpose. One of them, 3,3′-bis(β-hydroxyethyl)-9-ethyl-5,5′-dimethoxythiacarbocyanine iodide (N744), is a cationic thiacarbocyanine dye that inhibits recombinant tau filament formation when present at submicromolar concentrations. To prepare dosing regimens for testing N744 activity in biological models, its full concentration-effect relationship in the range 0.01 – 60 μM was examined in vitro by electron microscopy and laser light scattering methods. Results revealed that N744 concentration dependence was biphasic, with fibrillization inhibitory activity appearing at submicromolar concentration, but with relief of inhibition and increases in fibrillization apparent above 10 μM. Therefore, fibrillization was inhibited ≥50% only over a narrow concentration range, which was further reduced by filament stabilizing modifications such as tau pseudophosphorylation. N744 inhibitory activity also was paralleled by changes in its aggregation state, with dimer predominating at inhibitory concentrations and large dye aggregates appearing at high concentrations. Ligand dimerization was promoted by the presence of tau protein, which lowered the equilibrium dissociation constant for dimerization more than an order of magnitude relative to controls. The results suggest that ligand aggregation may play an important role in both inhibitory and disinhibitory phases of the concentration-effect curve, and may lead to complex dose response relationships in model systems. PMID:17559794
1986-01-14
Range : 2.52 million miles (1.56 million miles) P-29481B/W Voyager 2 returned this photograph with all nine known Uranus rings visible from a 15 sec. exposure through the narrow angle camera. The rings are quite dark and very narrow. The most prominent and outermost of the nine, Epsilon, is seen at top. The next three in toward Uranus, called Delta, Gamma, and Eta, are much fainter and more narrow than Epsilon ring. Then come Beta and Alpha rings, and finally, the innermost grouping, known simply as the 4,5, & 6 rings. The last three are very faint and are at the limit of detection for the Voyager camera. Uranus' rings range in width from about 100 km. (60 mi.) at the widest part of the Epsilon ring, to only a few kilometers for most of the others. this iamge was processed to enhance narrow features; the bright dots are imperfections on the camera detector. The resolution scale is about 50 km. (30 mi.)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geddes, Cameron; Ludewigt, Bernhard; Valentine, John
Near-monoenergetic photon sources (MPSs) have the potential to improve sensitivity at greatly reduced dose in existing applications and enable new capabilities in other applications. MPS advantages include the ability to select energy, energy spread, flux, and pulse structures to deliver only the photons needed for the application, while suppressing extraneous dose and background. Some MPSs also offer narrow divergence photon beams which can target dose and/or mitigate scattering contributions to image contrast degradation. Current broad-band, bremsstrahlung photon sources (e.g., linacs and betatrons) deliver unnecessary dose that in some cases also interferes with the signature to be detected and/or restricts operations,more » and must be collimated (reducing flux) to generate narrow divergence beams. While MPSs can in principle resolve these issues, they are technically challenging to produce. Candidate MPS technologies for nonproliferation applications are now being developed, each of which have different properties (e.g. broad divergence vs. narrow). Within each technology, source parameters trade off against one another (e.g. flux vs. energy spread), representing a large operation space. To guide development, requirements for each application of interest must be defined and simulations conducted to define MPS parameters that deliver benefit relative to current systems. The present project conducted a broad assessment of potential nonproliferation applications where MPSs may provide new capabilities or significant performance enhancement (reported separately), which led to prioritization of several applications for detailed analysis. The applications prioritized were: cargo screening and interdiction of Special Nuclear Materials (SNM), detection of hidden SNM, treaty/dismantlement verification, and spent fuel dry storage cask content verification. High resolution imaging for stockpile stewardship was considered as a sub-area of the treaty topic, as it is also of interest for future treaty use. This report presents higher-fidelity calculations and modeling results to quantitatively evaluate the prioritized applications, and to derive the key MPS properties that drive application benefit. Simulations focused on the conventional signatures of radiography, photofission, and NRF to enable comparison to present methods and evaluation of benefit.« less
Heavy-ion dominance near Cluster perigees
NASA Astrophysics Data System (ADS)
Ferradas, C. P.; Zhang, J.-C.; Kistler, L. M.; Spence, H. E.
2015-12-01
Time periods in which heavy ions dominate over H+ in the energy range of 1-40 keV were observed by the Cluster Ion Spectrometry (CIS)/COmposition DIstribution Function (CODIF) instrument onboard Cluster Spacecraft 4 at L values less than 4. The characteristic feature is a narrow flux peak at around 10 keV that extends into low L values, with He+ and/or O+ dominating. In the present work we perform a statistical study of these events and examine their temporal occurrence and spatial distribution. The observed features, both the narrow energy range and the heavy-ion dominance, can be interpreted using a model of ion drift from the plasma sheet, subject to charge exchange losses. The narrow energy range corresponds to the only energy range that has direct drift access from the plasma sheet during quiet times. The drift time to these locations from the plasma sheet is > 30 h, so that charge exchange has a significant impact on the population. We show that a simple drift/loss model can explain the dependence on L shell and MLT of these heavy-ion-dominant time periods.
Looe, Hui Khee; Delfs, Björn; Poppinga, Daniela; Harder, Dietrich; Poppe, Björn
2017-06-21
The distortion of detector reading profiles across photon beams in the presence of magnetic fields is a developing subject of clinical photon-beam dosimetry. The underlying modification by the Lorentz force of a detector's lateral dose response function-the convolution kernel transforming the true cross-beam dose profile in water into the detector reading profile-is here studied for the first time. The three basic convolution kernels, the photon fluence response function, the dose deposition kernel, and the lateral dose response function, of wall-less cylindrical detectors filled with water of low, normal and enhanced density are shown by Monte Carlo simulation to be distorted in the prevailing direction of the Lorentz force. The asymmetric shape changes of these convolution kernels in a water medium and in magnetic fields of up to 1.5 T are confined to the lower millimetre range, and they depend on the photon beam quality, the magnetic flux density and the detector's density. The impact of this distortion on detector reading profiles is demonstrated using a narrow photon beam profile. For clinical applications it appears as favourable that the magnetic flux density dependent distortion of the lateral dose response function, as far as secondary electron transport is concerned, vanishes in the case of water-equivalent detectors of normal water density. By means of secondary electron history backtracing, the spatial distribution of the photon interactions giving rise either directly to secondary electrons or to scattered photons further downstream producing secondary electrons which contribute to the detector's signal, and their lateral shift due to the Lorentz force is elucidated. Electron history backtracing also serves to illustrate the correct treatment of the influences of the Lorentz force in the EGSnrc Monte Carlo code applied in this study.
SU-F-T-673: Effects of Cardiac Induced Brain Pulsations On Proton Minibeams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eagle, J; Marsh, S; Lee, E
Purpose: To quantify the dosimetric impact of internal motion within the brain on spatially modulated proton minibeam radiation therapy (pMRT) for small animal research. Methods: The peak-to-valley dose ratio (PVDR) is an essential dosimetric factor for pMRT. Motion of an animal brain caused by cardiac-induced pulsations (CIP) can impact dose deposition. For synchrotron generated high dose rate X-ray microbeams this effect is evaded due to the quasi-instantaneous delivery. By comparison, pMRT potentially suffers increased spread due to lower dose rates. However, for a given dose rate it is less susceptible to beam spread than microbeams, due to the spatial modulationmore » being an order of magnitude larger. Monte Carlo simulations in TOPAS were used to model the beam spread for a 50.5MeV pMRT beam. Motion effects were simulated for a 50mm thick brass collimator with 0.3mm slit width and 1.0mm center-to-center spacing in a water phantom. The maximum motion in a rat brain due to CIP has been reported to be 0.06mm. Motion was simulated with a peak amplitude in the range 0–0.2mm. Results: The impact of 0.06mm peak motion was minimal and reduced the PVDR by about 1% at a depth of 10mm. For 0.2mm peak motion the PVDR was reduced by 16% at a depth of 10mm. Conclusion: For the pMRT beam the magnitude of cardiac-induced brain motion has minimal impact on the PVDR for the investigated collimator geometry. For more narrow beams the effect is likely to be larger. This indicates that delivery of pMRT to small animal brains should not be affected considerably by beamlines with linac compatible dose rates.« less
Compact MEMS external cavity tunable laser with ultra-narrow linewidth for coherent detection.
Zhang, Di; Zhao, Jianyi; Yang, Qi; Liu, Wen; Fu, Yanfeng; Li, Chao; Luo, Ming; Hu, Shenglei; Hu, Qianggao; Wang, Lei
2012-08-27
A compact and ultra-narrow linewidth tunable laser with an external cavity based on a simple single-axis-MEMS mirror is presented in this paper. We discuss the simulation of this tunable laser using a two-step hybrid analysis method to obtain an optimal design of the device. A wide wavelength tuning range about 40 nm in C-band with a narrow linewidth of less than 50 kHz and wavelength accuracy of ± 1 GHz over the entire tuning range can be achieved experimentally. We also conduct several experiments under different conditions to test the tunable laser. This device shows an excellent performance in both single-carrier polarization-multiplexed quadrature phase-shift keying (PM-QPSK) and multi-carrier orthogonal frequency division multiplexing (OFDM) coherent systems.
Tsuruoka, Chizuru; Blyth, Benjamin J; Morioka, Takamitsu; Kaminishi, Mutsumi; Shinagawa, Mayumi; Shimada, Yoshiya; Kakinuma, Shizuko
2016-10-01
Recently reported studies have led to a heightened awareness of the risks of cancer induced by diagnostic radiological imaging, and in particular, the risk of brain cancer after childhood CT scans. One feature of Ptch1 +/- mice is their sensitivity to radiation-induced medulloblastomas (an embryonic cerebellar tumor) during a narrow window of time centered on the days around birth. Little is known about the dynamics of how dose protraction interacts with such narrow windows of sensitivity in individual tissues. Using medulloblastomas from irradiated Ptch1 +/- mice with a hybrid C3H × C57BL/6 F1 genetic background, we previously showed that the alleles retained on chromosome 13 (which harbors the Ptch1 gene) reveal two major mechanisms of loss of the wild-type allele. The loss of parental alleles from the telomere extending up to or past the Ptch1 locus by recombination (spontaneous type) accounts for almost all medulloblastomas in nonirradiated mice, while tumors in irradiated mice often exhibited interstitial deletions, which start downstream of the wild-type Ptch1 and extend up varying lengths towards the centromere (radiation type). In this study, Ptch1 +/- mice were exposed to an acute dose of either 100 or 500 mGy gamma rays in utero or postnatally, or the same radiation doses protracted over a four-day period, and were monitored for medulloblastoma development. The results showed dose- and age-dependent radiation-induced type tumors. Furthermore, the size of the radiation-induced deletion differed with the dose rate. The results of this work suggest that tumor latency may be related to the size of the deletion. In this study, 500 mGy exposure produced radiation-induced type tumors at all ages and dose rates, while 100 mGy exposure did not significantly produce radiation-induced type tumors. The radiation signature allows for unique mechanistic insight into the action of radiation to induce DNA lesions with known causal relationship to a specific tumor type, particularly for doses and dose rates that are relevant to both diagnostic and accidental radiological exposures.
Theory of electric resonance in the neocortical apical dendrite.
Kasevich, Ray S; LaBerge, David
2011-01-01
Pyramidal neurons of the neocortex display a wide range of synchronous EEG rhythms, which arise from electric activity along the apical dendrites of neocortical pyramidal neurons. Here we present a theoretical description of oscillation frequency profiles along apical dendrites which exhibit resonance frequencies in the range of 10 to 100 Hz. The apical dendrite is modeled as a leaky coaxial cable coated with a dielectric, in which a series of compartments act as coupled electric circuits that gradually narrow the resonance profile. The tuning of the peak frequency is assumed to be controlled by the average amplitude of voltage-gated outward currents, which in turn are regulated by the subthreshold noise in the thousands of synaptic spines that are continuously bombarded by local circuits. The results of simulations confirmed the ability of the model both to tune the peak frequency in the 10-100 Hz range and to gradually narrow the resonance profile. Considerable additional narrowing of the resonance profile is provided by repeated looping through the apical dendrite via the corticothalamocortical circuit, which reduced the width of each resonance curve (at half-maximum) to approximately 1 Hz. Synaptic noise in the neural circuit is discussed in relation to the ways it can influence the narrowing process.
Theory of Electric Resonance in the Neocortical Apical Dendrite
Kasevich, Ray S.; LaBerge, David
2011-01-01
Pyramidal neurons of the neocortex display a wide range of synchronous EEG rhythms, which arise from electric activity along the apical dendrites of neocortical pyramidal neurons. Here we present a theoretical description of oscillation frequency profiles along apical dendrites which exhibit resonance frequencies in the range of 10 to 100 Hz. The apical dendrite is modeled as a leaky coaxial cable coated with a dielectric, in which a series of compartments act as coupled electric circuits that gradually narrow the resonance profile. The tuning of the peak frequency is assumed to be controlled by the average amplitude of voltage-gated outward currents, which in turn are regulated by the subthreshold noise in the thousands of synaptic spines that are continuously bombarded by local circuits. The results of simulations confirmed the ability of the model both to tune the peak frequency in the 10–100 Hz range and to gradually narrow the resonance profile. Considerable additional narrowing of the resonance profile is provided by repeated looping through the apical dendrite via the corticothalamocortical circuit, which reduced the width of each resonance curve (at half-maximum) to approximately 1 Hz. Synaptic noise in the neural circuit is discussed in relation to the ways it can influence the narrowing process. PMID:21853129
Tompson, Debra J; Crean, Christopher S; Buraglio, Mauro; Arumugham, Thangam
2014-01-01
Introduction The potential for ezogabine/retigabine (EZG/RTG) and its N-acetyl metabolite (NAMR) to inhibit the transporter protein P-glycoprotein-(P-gp)-mediated digoxin transport was tested in vitro. EZG/RTG did not inhibit P-gp. However, NAMR inhibited P-gp in a concentration-dependent manner. Based on these in vitro results, NAMR had the potential to inhibit P-gp at therapeutic doses of EZG/RTG (600–1,200 mg/day). As digoxin has a narrow therapeutic index, inhibition of digoxin clearance may have an impact on its safety. Methods An open-label, single-center, two session, fixed-sequence study was conducted to assess the effect of co-administration of therapeutic doses of EZG/RTG on digoxin pharmacokinetics in healthy adults. In session 1, subjects received a single dose of digoxin 0.25 mg. In session 2, EZG/RTG was up-titrated over 6 weeks. Digoxin 0.25 mg was co-administered at EZG/RTG steady-state doses of 600, 900, and, based on tolerability, 1,050/1,200 mg/day. Blood samples were collected over 144 hours for determination of digoxin, EZG/RTG, and NAMR concentrations. Urine samples were collected over 48 hours for determination of digoxin concentrations. Results Of 30 subjects enrolled, 29 were included in the pharmacokinetic analysis. Compared with digoxin alone, co-administration with EZG/RTG led to small increases in the digoxin plasma area under the concentration–time curve (AUC)0–120 at doses of 600, 900, and 1,050/1,200 mg (geometric mean ratio 1.08, 90% confidence interval [CI] 1.01–1.15; 1.18, 90% CI 1.10–1.27; 1.13, 90% CI 1.05–1.21, respectively). Safety was consistent with previous repeat-dose studies of EZG/RTG in healthy subjects. Conclusion Co-administration of EZG/RTG across the therapeutic range resulted in small, non-dose-dependent and non-clinically relevant increases in digoxin systemic exposure, suggesting that digoxin dose adjustment is not necessary. PMID:25342921
Gasparini, Maurizio; Galimberti, Paola; Bragato, Renato; Ghio, Stefano; Raineri, Claudia; Landolina, Maurizio; Chieffo, Enrico; Lunati, Maurizio; Mulargia, Ederina; Proclemer, Alessandro; Facchin, Domenico; Rordorf, Roberto; Vicentini, Alessandro; Marcantoni, Lina; Zanon, Francesco; Klersy, Catherine
2016-12-03
Despite an intensive search for predictors of the response to cardiac resynchronization therapy (CRT), the QRS duration remains the simplest and most robust predictor of a positive response. QRS duration of ≥ 130 ms is considered to be a prerequisite for CRT; however, some studies have shown that CRT may also be effective in heart failure (HF) patients with a narrow QRS (<130 ms). Since CRT can now be performed by pacing the left ventricle from multiple vectors via a single quadripolar lead, it is possible that multipoint pacing (MPP) might be effective in HF patients with a narrow QRS. This article reports the design of the MPP Narrow QRS trial, a prospective, randomized, multicenter, controlled feasibility study to investigate the efficacy of MPP using two LV pacing vectors in patients with a narrow QRS complex (100-130 ms). Fifty patients with a standard ICD indication will be enrolled and randomized (1:1) to either an MPP group or a Standard ICD group. All patients will undergo a low-dose dobutamine stress echo test and only those with contractile reserve will be included in the study and randomized. The primary endpoint will be the percentage of patients in each group that have reverse remodeling at 12 months, defined as a reduction in left ventricular end-systolic volume (LVESV) of >15% from the baseline. This feasibility study will determine whether MPP improves reverse remodeling, as compared with standard ICD, in HF patients who have a narrow QRS complex (100-130 ms). ClinicalTrials.gov, NCT02402816 . Registered on 25 March 2015.
Narrow beam neutron dosimetry.
Ferenci, M Sutton
2004-01-01
Organ and effective doses have been estimated for male and female anthropomorphic mathematical models exposed to monoenergetic narrow beams of neutrons with energies from 10(-11) to 1000 MeV. Calculations were performed for anterior-posterior, posterior-anterior, left-lateral and right-lateral irradiation geometries. The beam diameter used in the calculations was 7.62 cm and the phantoms were irradiated at a height of 1 m above the ground. This geometry was chosen to simulate an accidental scenario (a worker walking through the beam) at Flight Path 30 Left (FP30L) of the Weapons Neutron Research (WNR) Facility at Los Alamos National Laboratory. The calculations were carried out using the Monte Carlo transport code MCNPX 2.5c.
H-tailored surface conductivity in narrow band gap In(AsN)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Velichko, A. V., E-mail: amalia.patane@nottingham.ac.uk, E-mail: anton.velychko@nottingham.ac.uk; Patanè, A., E-mail: amalia.patane@nottingham.ac.uk, E-mail: anton.velychko@nottingham.ac.uk; Makarovsky, O.
2015-01-12
We show that the n-type conductivity of the narrow band gap In(AsN) alloy can be increased within a thin (∼100 nm) channel below the surface by the controlled incorporation of H-atoms. This channel has a large electron sheet density of ∼10{sup 18 }m{sup −2} and a high electron mobility (μ > 0.1 m{sup 2}V{sup −1}s{sup −1} at low and room temperature). For a fixed dose of impinging H-atoms, its width decreases with the increase in concentration of N-atoms that act as H-traps thus forming N-H donor complexes near the surface.
Dose in bone and tissue near bone-tissue interface from electron beam.
Shiu, A S; Hogstrom, K R
1991-08-01
This work has quantitatively studied the variation of dose both within bone and in unit density tissue near bone-tissue interfaces. Dose upstream of a bone-tissue interface is increased because of an increase in the backscattered electrons from the bone. The magnitude of this effect was measured using a thin parallel-plate ionization chamber upstream of a polymethyl methacrylate (PMMA)-hard bone interface. The electron backscatter factor (EBF) increased rapidly with bone thickness until a full EBF was achieved. This occurred at approximately 3.5 mm at 2 MeV and 6 mm at 13.1 MeV. The full EBF at the interface ranged from approximately 1.018 at 13.1 MeV to 1.05 at 2 MeV. It was also observed that the EBF had a dependence on the energy spectrum at the interface. The penetration of the backscattered electrons in the upstream direction of PMMA was also measured. The dose penetration fell off rapidly in the upstream direction of the interface. Dose enhancement to unit density tissue in bone was measured for an electron beam by placing thermoluminescent dosimeters (TLDs) in a PMMA-bone-PMMA phantom. The maximum dose enhancement in bone was approximately 7% of the maximum dose in water. However, the pencil-beam algorithm of Hogstrom et al. predicted an increase of only 1%, primarily owing to the inverse-square correction. Film was also used to measure the dose enhancement in bone. The film plane was aligned either perpendicular or parallel to the central axis of the beam. The film data indicated that the maximum dose enhancement in bone was approximately 8% for the former film alignment (which was similarly predicted by the TLD measurements) and 13% for the latter film alignment. These results confirm that the X ray film is not suitable to be irritated "edge on" in an inhomogeneous phantom without making perturbation corrections resulting from the film acting as a long narrow inhomogeneous cavity within the bone. In addition, the results give the radiotherapist a basis for clinical judgment when electron beams are used to treat lesions behind bone or near bony structures. We feel these data enhance the ability to recognize the shortcomings of the current dose calculation algorithm used clinically.
Effects of the increase in neuronal fatty acids availability on food intake and satiety in mice.
Coccurello, Roberto; Caprioli, Antonio; Bellantuono, Sara; D'Amato, Francesca R; Conti, Roberto; Giannessi, Fabio; Borsini, Franco; Moles, Anna
2010-05-01
Neurons detect free fatty acids (FFAs) availability and use this nutritional status to modulate feeding and control body weight. The work is designed to characterize the impact on feeding behavior of either oleic acid (OA) administration (experiment 1) or the inhibition (experiment 2) of the enzyme carnitine palmitoyltransferase-1 (CPT-1). The structure of feeding behavior and satiation time course were examined through the behavioral satiety sequence (BSS) paradigm. Adult male mice were initially habituated to a palatable diet, then subjected to intracerebroventricular (i.c.v.) infusion of different doses of OA or the CPT-1 inhibitor ST1326. Food intake at different time points, duration, and frequencies of feeding and non-feeding-related behaviors were continuously monitored over 40 min and satiety development profiled according to BSS. Intra-i.c.v. infusion of oleic acid (300 nM) and ST1326 (50 and 75 pM) suppressed food intake. As indicated by the earlier leftward shifting of the normal transition from eating to resting, both strategies similarly accelerated the onset of satiety. The premature onset of satiety resulted in a dose-related fashion with 50 pM of ST1326 producing a marked premature onset than the lower dose. However, at the highest dose injected, the inhibition of CPT-1 disrupted the BSS profile. The increased neuronal availability of FFAs mediates a significant anorectic response which is mirrored by an early occurrence of satiety onset. Besides supporting the role of central nutrient sensing in feeding, the present data demonstrate that the modulation of satiety enhancement can produce appetite suppressant effects within narrow range of neuronal FFAs availability.
McLean, Samantha L; Grayson, Ben; Marsh, Samuel; Zarroug, Samah H O; Harte, Michael K; Neill, Jo C
2016-04-01
Cholinergic dysfunction has been shown to be central to the pathophysiology of Alzheimer's disease and has also been postulated to contribute to cognitive dysfunction observed in various psychiatric disorders, including schizophrenia. Deficits are found across a number of cognitive domains and in spite of several attempts to develop new therapies, these remain an unmet clinical need. In the current study we investigated the efficacy of donepezil, risperidone and selective nicotinic α7 and α4β2 receptor agonists to reverse a delay-induced deficit in recognition memory. Adult female Hooded Lister rats received drug treatments and were tested in the novel object recognition (NOR) task following a 6h inter-trial interval (ITI). In all treatment groups, there was no preference for the left or right identical objects in the acquisition trial. Risperidone failed to enhance recognition memory in this paradigm whereas donepezil was effective such that rats discriminated between the novel and familiar object in the retention trial following a 6h ITI. Although a narrow dose range of PNU-282987 and RJR-2403 was tested, only one dose of each increased recognition memory, the highest dose of PNU-282987 (10mg/kg) and the lowest dose of RJR-2403 (0.1mg/kg), indicative of enhanced cognitive performance. Interestingly, these compounds were also efficacious when administered either before the acquisition or the retention trial of the task, suggesting an important role for nicotinic receptor subtypes in the formation and retrieval of recognition memory. Copyright © 2016. Published by Elsevier B.V.
A clinical assay for the measurement of milrinone in plasma by HPLC mass spectrometry.
Chihoho, B; Sage, A B; Smolenski, R T; Vazir, A; Rose, M L; Banner, N R; Leaver, N V
2012-05-01
Milrinone is a bipyridine phosphodiesterase inhibitor with positive inotropic and vasodilatory effects. As interest in longer term use of intravenous therapy increases, it becomes essential to monitor its plasma concentration owing to a narrow therapeutic range, an increased half-life in renal failure and toxicity associated with high levels. A high-performance liquid chromatography (HPLC) method with mass (MS) detection using a triple quadrupole mass spectrometer is presented. The method was compared with the UV/HPLC method and validated according to current international guidelines. Coefficients of variation of less than 7.5% were obtained across the therapeutic range and 18.3% at 2.4 ng/mL, the lower limit of quantitation. Plasma from 13 cardiac surgery patients receiving standard intravenous doses of milrinone were measured. Eight patients achieved therapeutic milrinone levels within 3-4 h post start of infusion, one was borderline sub-therapeutic and four patients achieved levels that were above the upper limit of the therapeutic range and potentially toxic. This method offers high sensitivity, is rapid, easy to use and requires minimal amount of sample. We believe this method could become the reference procedure for clinical monitoring of milrinone and help to improve the safety of the use of this drug in patients with cardiac failure. Copyright © 2011 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Posada-Ramírez, B.; Durán-Sánchez, M.; Álvarez-Tamayo, R. I.; Ibarra-Escamilla, B.; Hernández-Arriaga, M. V.; Sánchez-de-la-Llave, D.; Kuzin, E. A.
2017-08-01
We propose an all-fiber Tm-doped fiber laser with a tunable and narrow laser line generated in a wavelength region of 2 µm. A single laser line with a linewidth below 0.05 nm, tunable in a wavelength range of 44.25 nm, is obtained. The laser linewidth and the discrete wavelength tuning range depend on the characteristics of the two fiber optical loop mirrors with high birefringence in the loop that forms the cavity. Dual-wavelength laser operation is also observed at tuning range limits with a wavelength separation of 47 nm. Alternate wavelength switching is also observed.
NASA Technical Reports Server (NTRS)
Gardner, William N.; Edmondson, James L.
1950-01-01
A flight test was made to determine the servoplane effectiveness and stability characteristics of the free-floating horizontal stabilizer to be used on the XF10F airplane. The results of this test indicate that servoplane effectiveness is practically constant through the speed range up to a Mach number of 1.15, and the stabilizer static stability is satisfactory. A loss of damping occurs over a narrow Mach number range near M = 1.0, resulting in dynamic instability of the stabilizer in this narrow range. Above M = 1.0 there is a gradual positive trim change of the stabilizer.
A Healthy Dose of Race? White Students' and Teachers' Unintentional Brushes with Whiteness
ERIC Educational Resources Information Center
Schulz, Samantha; Fane, Jennifer
2015-01-01
This paper reports on efforts by three Australian academics to develop students' sociocultural awareness (in particular, their racial literacy) during a time of mounting pressure on teacher educators to narrow and standardise their approaches. The field of health education provides a vehicle for research; however, it is not the paper's central…
NASA Astrophysics Data System (ADS)
Garmire, Gordon
2016-09-01
We propose to observe a complete sample of 10 galaxy clusters at 1e14 < M500 < 5e14 and 0.7 < z < 0.8. These systems were selected from the 100 deg^2 deep field of the SPT-Pol SZ survey. This survey are has significant complementary data, including uniform depth ATCA, Herschel, Spitzer, and DES imaging, enabling a wide variety of astrophysical and cosmological studies. This sample complements the successful SPT-XVP survey, which has a broad redshift range and a narrow mass range, by including clusters over a narrow redshift range and broad mass range. These systems are such low mass and high redshift that they will not be detected in the eRosita all-sky survey.
NASA Astrophysics Data System (ADS)
Chardin, Jonathan; Haehnelt, Martin G.; Bosman, Sarah E. I.; Puchwein, Ewald
2018-01-01
High signal-to-noise observations of the Ly α forest transmissivity in the z = 7.085 quasi-stellar object (QSO) ULAS J1120+0641 show seven narrow transmission spikes followed by a long 240 cMpc h-1 trough. Here, we use radiative transfer simulations of cosmic reionization previously calibrated to match a wider range of Ly α forest data to show that the occurrence of seven transmission spikes in the narrow redshift range z = 5.85-6.1 is very sensitive to the exact timing of reionization. Occurrence of the spikes requires the most underdense regions of the intergalactic medium to be already fully ionized. The rapid onset of a long trough at z = 6.12 requires a strong decrease of the photoionization rate Γ at z ≳ 6.1 in this line of sight, consistent with the end of percolation at this redshift. The narrow range of reionization histories that we previously found to be consistent with a wider range of Ly α forest data have a reasonable probability of showing seven spikes and the mock absorption spectra provide an excellent match to the spikes and the trough in the observed spectrum of ULAS J1120+0641. Larger samples of high signal-to-noise searches for rare Ly α transmission spikes at z > 5.8 should therefore provide important further insights into the exact timing of the percolation of H II bubbles at the tail end of reionization.
Schoville, Sean D; Slatyer, Rachel A; Bergdahl, James C; Valdez, Glenda A
2015-07-01
For many terrestrial species, habitat associations and range size are dependent on physiological limits, which in turn may influence large-scale patterns of species diversity. The temperature range experienced by individuals is considered to shape the breadth of the thermal niche, with species occupying temporally and/or geographically stable climates tolerating a narrow temperature range. High-elevation environments experience large temperature fluctuations, with frequent periods below 0 °C, but Grylloblatta (Grylloblattodea: Grylloblattidae) occupy climatically stable microhabitats within this region. Here we test critical thermal limits and supercooling points for five Grylloblatta populations from across a large geographic area, to examine whether the stable microhabitats of this group are associated with a narrow thermal niche and assess their capacity to tolerate cold conditions. Thermal limits are highly conserved in Grylloblatta, despite substantial genetic divergence among populations spanning 1500 m elevation and being separated by over 500 km. Further, Grylloblatta show exceptionally narrow thermal limits compared to other insect taxa with little capacity to improve cold tolerance via plasticity. In contrast, upper thermal limits were significantly depressed by cold acclimation. Grylloblatta maintain coordinated movement until they freeze, and they die upon freezing. Convergence of the critical thermal minima, supercooling point and lower lethal limits point to adaptation to a cold but, importantly, constant thermal environment. These physiological data provide an explanation for the high endemism and patchy distribution of Grylloblatta, which relies on subterranean retreats to accommodate narrow thermal limits. These retreats are currently buffered from temperature fluctuations by snow cover, and a declining snowpack thus places Grylloblatta at risk of exposure to temperatures beyond its tolerance capacity. Copyright © 2015 Elsevier Ltd. All rights reserved.
Johnson, JA; Gong, L; Whirl-Carrillo, M; Gage, BF; Scott, SA; Stein, CM; Anderson, JL; Kimmel, SE; Lee, MTM; Pirmohamed, M; Wadelius, M; Klein, TE; Altman, RB
2011-01-01
Warfarin is a widely used anticoagulant with a narrow therapeutic index and large interpatient variability in the dose required to achieve target anticoagulation. Common genetic variants in the cytochrome P450-2C9 (CYP2C9) and vitamin K–epoxide reductase complex (VKORC1) enzymes, in addition to known nongenetic factors, account for ~50% of warfarin dose variability. The purpose of this article is to assist in the interpretation and use of CYP2C9 and VKORC1 geno-type data for estimating therapeutic warfarin dose to achieve an INR of 2–3, should genotype results be available to the clinician. The Clinical Pharmacogenetics Implementation Consortium (CPIC) of the National Institutes of Health Pharmacogenomics Research Network develops peer-reviewed gene–drug guidelines that are published and updated periodically on http://www.pharmgkb.org based on new developments in the field.1 PMID:21900891
Warfarin therapy: in need of improvement after all these years
Kimmel, Stephen E
2010-01-01
Background Warfarin therapy has been used clinically for over 60 years, yet continues to be problematic because of its narrow therapeutic index and large inter-individual variability in patient response. As a result, warfarin is a leading cause of serious medication-related adverse events, and its efficacy is also suboptimal. Objective To review factors that are responsible for variable response to warfarin, including clinical, environmental, and genetic factors, and to explore some possible approaches to improving warfarin therapy. Results Recent efforts have focused on developing dosing algorithms that included genetic information to try to improve warfarin dosing. These dosing algorithms hold promise, but have not been fully validated or tested in rigorous clinical trials. Perhaps equally importantly, adherence to warfarin is a major problem that should be addressed with innovative and cost-effective interventions. Conclusion Additional research is needed to further test whether interventions can be used to improve warfarin dosing and outcomes. PMID:18345947
Glavičić, Snježana; Anić, Ivica; Braut, Alen; Miletić, Ivana; Borčić, Josipa
2011-08-01
The purpose was to measure and analyse the vertical force and torque developed in the wider and narrower root canals during hand ProTaper instrumentation. Twenty human incisors were divided in two groups. Upper incisors were experimental model for the wide, while the lower incisors for the narrow root canals. Measurements of the force and torque were done by a device constructed for this purpose. Differences between the groups were statistically analysed by Mann-Whitney U-test with the significance level set to P<0.05. Vertical force in the upper incisors ranged 0.25-2.58 N, while in the lower incisors 0.38-6.94 N. Measured torque in the upper incisors ranged 0.53-12.03 Nmm, while in the lower incisor ranged 0.94-10.0 Nmm. Vertical force and torque were higher in the root canals of smaller diameter. The increase in the contact surface results in increase of the vertical force and torque as well in both narrower and wider root canals. © 2010 The Authors. Australian Endodontic Journal © 2010 Australian Society of Endodontology.
A protein-dye hybrid system as a narrow range tunable intracellular pH sensor.
Anees, Palapuravan; Sudheesh, Karivachery V; Jayamurthy, Purushothaman; Chandrika, Arunkumar R; Omkumar, Ramakrishnapillai V; Ajayaghosh, Ayyappanpillai
2016-11-18
Accurate monitoring of pH variations inside cells is important for the early diagnosis of diseases such as cancer. Even though a variety of different pH sensors are available, construction of a custom-made sensor array for measuring minute variations in a narrow biological pH window, using easily available constituents, is a challenge. Here we report two-component hybrid sensors derived from a protein and organic dye nanoparticles whose sensitivity range can be tuned by choosing different ratios of the components, to monitor the minute pH variations in a given system. The dye interacts noncovalently with the protein at lower pH and covalently at higher pH, triggering two distinguishable fluorescent signals at 700 and 480 nm, respectively. The pH sensitivity region of the probe can be tuned for every unit of the pH window resulting in custom-made pH sensors. These narrow range tunable pH sensors have been used to monitor pH variations in HeLa cells using the fluorescence imaging technique.
Ultra-narrow pulse generator with precision-adjustable pulse width
NASA Astrophysics Data System (ADS)
Fu, Zaiming; Liu, Hanglin
2018-05-01
In this paper, a novel ultra-narrow pulse generation approach is proposed. It is based on the decomposition and synthesis of pulse edges. Through controlling their relative delay, an ultra-narrow pulse could be generated. By employing field programmable gate array digital synthesis technology, the implemented pulse generator is with programmable ability. The amplitude of pulse signals is controlled by the radio frequency amplifiers and bias tees, and high precision can be achieved. More importantly, the proposed approach can break through the limitation of device's propagation delay and optimize the resolution and the accuracy of the pulse width significantly. The implemented pulse generator has two channels, whose minimum pulse width, frequency range, and amplitude range are 100 ps, 15 MHz-1.5 GHz, and 0.1 Vpp-1.8 Vpp, respectively. Both resolution of pulse width and channel delay are 1 ps, and amplitude resolution is 10 mVpp.
Evaluation of the uncertainties in the TLD radiosurgery postal dose system
NASA Astrophysics Data System (ADS)
Campos, L. T.; Leite, S. P.; de Almeida, C. E. V.; Magalhães, L. A. G.
2018-03-01
Stereotactic radiosurgery is a single-fraction radiation therapy procedure for treating intracranial lesions using a stereotactic apparatus and multiple narrow beams delivered through noncoplanar isocentric arcs. To guarantee a high quality standard, a comprehensive Quality Assurance programme is extremely important to ensure that the measured dose is consistent with the tolerance considered to improve treatment quality. The Radiological Science Laboratory operates a postal audit programme in SRT and SRS. The purpose of the programme is to verify the target localization accuracy in known geometry and the dosimetric conditions of the TPS. The programme works in such a way those thermoluminescence dosimeters, consisting of LiF chips, are sent to the centre where they are to be irradiated to a certain dose. The TLD are then returned, where they are evaluated and the absorbed dose is obtained from TLDs readings. The aim of the present work is estimate the uncertainties in the process of dose determination, using experimental data.
Intersession reliability of self-selected and narrow stance balance testing in older adults.
Riemann, Bryan L; Piersol, Kelsey
2017-10-01
Despite the common practice of using force platforms to assess balance of older adults, few investigations have examined the reliability of postural screening tests in this population. We sought to determine the test-retest reliability of self-selected and narrow stance balance testing with eyes open and eyes closed in healthy older adults. Thirty older adults (>65 years) completed 45 s trials of eyes open and eyes closed stability tests using self-selected and narrow stances on two separate days (1.9 ± .7 days). Average medial-lateral center of pressure velocity was computed. The ICC results ranged from .74 to .86, and no significant systematic changes (P < .05) occurred between the testing sessions for any of the tests. The standard error of measurement ranged from 15.9 to 23.6%. Reliability estimates were similar between the two stances and visual conditions assessed. Slightly higher coefficients were identified for the self-selected stances compared to the narrow stances under both visual conditions; however, there were negligible differences between the sessions. The within subject session-to-session variability provides a basis for further research to consider differences between fallers and non-fallers. Reliability for eyes open and closed balance testing using self-selected and narrow stances in older adults was established which should provide a foundation for the development of fall risk screening tests.
Wu, Wenda; Zhou, Hui-Ren; Bursian, Steven J.; Pan, Xiao; Link, Jane E.; Berthiller, Franz; Adam, Gerhard; Krantis, Anthony; Durst, Tony; Pestka, James J.
2014-01-01
The mycotoxin deoxynivalenol (DON) elicits robust anorectic and emetic effects in several animal species. However, less is known about the potential for naturally occurring and synthetic congeners of this trichothecene to cause analogous responses. Here we tested the hypothesis that alterations in DON structure found in the plant metabolite deoxynivalenol-3-glucoside (D3G) and two pharmacologically active synthetic DON derivatives, EN139528 and EN139544, differentially impact their potential to evoke food refusal and emesis. In a nocturnal mouse food consumption model, oral administration with DON, D3G, EN139528, or EN139544 at doses from 2.5 to 10 mg/kg BW induced anorectic responses that lasted up to 16, 6, 6, and 3 h, respectively. Anorectic potency rank orders were EN139544>DON>EN139528>D3G from 0 to 0.5 h but DON>D3G>EN139528>EN139544 from 0 to 3 h. Oral exposure to each of the four compounds at a common dose (2.5 mg/kg BW) stimulated plasma elevations of the gut satiety peptides cholecystokinin and to a lesser extent, peptide YY3–36 that corresponded to reduced food consumption. In a mink emesis model, oral administration of increasing doses of the congeners differentially induced emesis, causing marked decreases in latency to emesis with corresponding increases in both the duration and number of emetic events. The minimum emetic doses for DON, EN139528, D3G, and EN139544 were 0.05, 0.5, 2, and 5 mg/kg BW, respectively. Taken together, the results suggest that although all three DON congeners elicited anorectic responses that mimicked DON over a narrow dose range, they were markedly less potent than the parent mycotoxin at inducing emesis. PMID:25173790
Smooth muscle in the maintenance of increased airway resistance elicited by methacholine in humans.
Chapman, David G; Pascoe, Chris D; Lee-Gosselin, Audrey; Couture, Christian; Seow, Chun Y; Paré, Peter D; Salome, Cheryl M; King, Gregory G; Bossé, Ynuk
2014-10-15
Airway narrowing is maintained for a prolonged period after acute bronchoconstriction in humans in the absence of deep inspirations (DIs). To determine whether maintenance of airway smooth muscle (ASM) shortening is responsible for the persistence of airway narrowing in healthy subjects following transient methacholine (MCh)-induced bronchoconstriction. On two separate visits, five healthy subjects underwent MCh challenges until respiratory system resistance (Rrs) had increased by approximately 1.5 cm H2O/L/s. Subjects took a DI either immediately after or 30 minutes after the last dose. The extent of renarrowing following the bronchodilator effect of DI was used to assess the continued action of MCh (calculated as percent change in Rrs from the pre-DI Rrs). We then used human bronchial rings to determine whether ASM can maintain shortening during a progressive decrease of carbachol concentration. The increased Rrs induced by MCh was maintained for 30 minutes despite waning of MCh concentration over that period, measured as attenuated renarrowing when the DI was taken 30 minutes after compared with immediately after the last dose (7 min post-DI, -36.2 ± 11.8 vs. 14.4 ± 13.2%; 12 min post-DI, -39.5 ± 9.8 vs. 15.2 ± 17.8%). Ex vivo, ASM shortening was largely maintained during a progressive decrease of carbachol concentration, even down to concentrations that would not be expected to induce shortening. The maintenance of airway narrowing despite MCh clearance in humans is attributed to an intrinsic ability of ASM to maintain shortening during a progressive decrease of contractile stimulation.
Effects of radiotherapy on parotid salivary sialochemistry in head and neck cancer patients.
Gupta, S C; Singla, Alok; Singh, Mangal; Thaliath, B Paul; Geeta, Jaiswal
2009-12-01
To determine the effects of high dose irradiation on parotid salivary sodium and pH concentration at subsequent duration of 1.5, 3 and 6 months following radiotherapy. Eighty parotid glands of head and neck cancer patients were irradiated with mean dose of 66 Gy. The stimulated parotid flow (PF) was collected by a cannulation of Stenson's duct followed by analysis of sodium (PF sodium) by Easylyte Sodium/Potassium auto analyzer and pH by litmus narrow band pH paper. A steep elevation of PF sodium was found in post-RT period after 1.5 months of starting RT followed by gradual increase up to 6 months and pH changed towards acidity. A high dose of 66 Gy causes irreversible damage to parotid salivary duct system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reft, C; Lu, Z; Noonan, J
2015-06-15
Purpose: An innovative small high intensity electron beams with energies from 6 to 12 MeV is being developed at Argonne National Laboratory to deliver an absorbed dose via a catheter to small malignant and nonmalignant lesions. This study reports on the initial dosimetric characteristics of this electron beam. These include output calibration, percent depth dose, beam profiles and leakage through the catheter. Methods: To simulate the narrow electron beam, the Argonne Wakefield Accelerator is used to produce high energy electron beams. The electron beam from the accelerator is monitored by measuring the current through a transmission coil while the beammore » shape is observed with a fluorescent screen. The dosimetry properties of the electron beam transmitting through bone and tissue-like materials are measured with nanodot optically stimulated luminescent dosimeters and EDR radiographic film. The 6 MV photon beam from a Varian True beam linac is used to calibrate both the OSLDs and the film. Results: The beam characteristics of the 12 MeV beam were measured. The properties of the small diameter, 5 mm, beam differs from that of broad clinical electron beams from radiotherapy linacs. Due to the lack of scatter from the narrow beam, the maximum dose is at the surface and the depth of the 50% depth dose is 35 mm compared to 51 mm for a clinical 12 MeV. The widths of the 90% isodose measured at the surface and depths of 2, 6, 12, and 16 mm varied from 6.6 to 8.8 mm while the widths of the FWHM isodose varied from 7.8 to 25.5 mm. Conclusion: Initial beam measurements show favorable dosimetric properties for its use in treating either small surface or internal lesions, particularly to deliver radiation at the time of surgery to maximize the dose to the lesion and spare normal tissue.« less
Narrow Angle Wide Spectral Range Radiometer Design FEANICS/REEFS Radiometer Design Report
NASA Technical Reports Server (NTRS)
Camperchioli, William
2005-01-01
A critical measurement for the Radiative Enhancement Effects on Flame Spread (REEFS) microgravity combustion experiment is the net radiative flux emitted from the gases and from the solid fuel bed. These quantities are measured using a set of narrow angle, wide spectral range radiometers. The radiometers are required to have an angular field of view of 1.2 degrees and measure over the spectral range of 0.6 to 30 microns, which presents a challenging design effort. This report details the design of this radiometer system including field of view, radiometer response, radiometric calculations, temperature effects, error sources, baffling and amplifiers. This report presents some radiometer specific data but does not present any REEFS experiment data.
Steady-state turbulence with a narrow inertial range
NASA Technical Reports Server (NTRS)
Weatherall, J. C.; Nicholson, D. R.; Goldman, M. V.
1983-01-01
Coupled two-dimensional wave equations are solved on a computer to model Langmuir wave turbulence excited by a weak electron beam. The model includes wave growth due to beam-plasma interaction, and dissipation by Landau damping. The inertial range is limited to a relatively small number of modes such as could occur when the ratio of masses between the negative and positive ions is larger than in a hydrogen plasma, or when there is damping in long wavelength Langmuir waves. A steady state is found consisting of quasistable, collapsed wave packets. The effects of different beam parameters and the assumed narrow inertial range are considered. The results may be relevant to plasma turbulence observed in connection with type III solar bursts.
A Chandra Survey of low-mass clusters at 0.8 < z < 0.9 selected in the 100 deg^2 SPT-Pol Deep Field
NASA Astrophysics Data System (ADS)
Kraft, Ralph
2016-09-01
We propose to observe a complete sample of 4 galaxy clusters at 1e14 < M500 < 3e14 and 0.8 < z < 0.9. These systems were selected from the 100 deg^2 deep field of the SPT-Pol SZ survey. This survey are has significant complementary data, including uniform depth ATCA, Herschel, Spitzer, and DES imaging, enabling a wide variety of astrophysical and cosmological studies. This sample complements the successful SPT-XVP survey, which has a broad redshift range and a narrow mass range, by including clusters over a narrow redshift range and broad mass range. These systems are such low mass and high redshift that they will not be detected in the eRosita all-sky survey.
A Chandra Survey of low-mass clusters at 0.7 < z < 0.8 selected in the 100 deg^2 SPT-Pol Deep Field
NASA Astrophysics Data System (ADS)
Kraft, Ralph
2016-09-01
We propose to observe a complete sample of 4 galaxy clusters at 1e14 < M500 < 3e14 and 0.7 < z < 0.8. These systems were selected from the 100 deg^2 deep field of the SPT-Pol SZ survey. This survey are has significant complementary data, including uniform depth ATCA, Herschel, Spitzer, and DES imaging, enabling a wide variety of astrophysical and cosmological studies. This sample complements the successful SPT-XVP survey, which has a broad redshift range and a narrow mass range, by including clusters over a narrow redshift range and broad mass range. These systems are such low mass and high redshift that they will not be detected in the eRosita all-sky survey.
McCarron, David A; Kazaks, Alexandra G; Geerling, Joel C; Stern, Judith S; Graudal, Niels A
2013-10-01
The recommendation to restrict dietary sodium for management of hypertensive cardiovascular disease assumes that sodium intake exceeds physiologic need, that it can be significantly reduced, and that the reduction can be maintained over time. In contrast, neuroscientists have identified neural circuits in vertebrate animals that regulate sodium appetite within a narrow physiologic range. This study further validates our previous report that sodium intake, consistent with the neuroscience, tracks within a narrow range, consistent over time and across cultures. Peer-reviewed publications reporting 24-hour urinary sodium excretion (UNaV) in a defined population that were not included in our 2009 publication were identified from the medical literature. These datasets were combined with those in our previous report of worldwide dietary sodium consumption. The new data included 129 surveys, representing 50,060 participants. The mean value and range of 24-hour UNaV in each of these datasets were within 1 SD of our previous estimate. The combined mean and normal range of sodium intake of the 129 datasets were nearly identical to that we previously reported (mean = 158.3±22.5 vs. 162.4±22.4 mmol/d). Merging the previous and new datasets (n = 190) yielded sodium consumption of 159.4±22.3 mmol/d (range = 114-210 mmol/d; 2,622-4,830mg/d). Human sodium intake, as defined by 24-hour UNaV, is characterized by a narrow range that is remarkably reproducible over at least 5 decades and across 45 countries. As documented here, this range is determined by physiologic needs rather than environmental factors. Future guidelines should be based on this biologically determined range.
Temporal intensity interferometry for characterization of very narrow spectral lines
NASA Astrophysics Data System (ADS)
Tan, P. K.; Kurtsiefer, C.
2017-08-01
Some stellar objects exhibit very narrow spectral lines in the visible range additional to their blackbody radiation. Natural lasing has been suggested as a mechanism to explain narrow lines in Wolf-Rayet stars. However, the spectral resolution of conventional astronomical spectrographs is still about two orders of magnitude too low to test this hypothesis. We want to resolve the linewidth of narrow spectral emissions in starlight. A combination of spectral filtering with single-photon-level temporal correlation measurements breaks the resolution limit of wavelength-dispersing spectrographs by moving the linewidth measurement into the time domain. We demonstrate in a laboratory experiment that temporal intensity interferometry can determine a 20-MHz-wide linewidth of Doppler-broadened laser light and identify a coherent laser light contribution in a blackbody radiation background.
Why some plant species are rare.
Wieger Wamelink, G W; Wamelink, G W Weiger; Goedhart, Paul W; Frissel, Joep; Frissel, Josep Y
2014-01-01
Biodiversity, including plant species diversity, is threatened worldwide as a result of anthropogenic pressures such as an increase of pollutants and climate change. Rare species in particular are on the verge of becoming extinct. It is still unclear as to why some plant species are rare and others are not. Are they rare due to: intrinsic reasons, dispersal capacity, the effects of management or abiotic circumstances? Habitat preference of rare plant species may play an important role in determining why some species are rare. Based on an extensive data set of soil parameters we investigated if rarity is due to a narrow habitat preference for abiotic soil parameters. For 23 different abiotic soil parameters, of which the most influential were groundwater-table, soil-pH and nutrient-contents, we estimated species responses for common and rare species. Based on the responses per species we calculated the range of occurrence, the range between the 5 and 95 percentile of the response curve giving the habitat preference. Subsequently, we calculated the average response range for common and rare species. In addition, we designed a new graphic in order to provide a better means for presentation of the results. The habitat preferences of rare species for abiotic soil conditions are significantly narrower than for common species. Twenty of the twenty-three abiotic parameters showed on average significantly narrower habitat preferences for rare species than for common species; none of the abiotic parameters showed on average a narrower habitat preference for common species. The results have major implications for the conservation of rare plant species; accordingly management and nature development should be focussed on the maintenance and creation of a broad range of environmental conditions, so that the requirements of rare species are met. The conservation of (abiotic) gradients within ecosystems is particularly important for preserving rare species.
Knies, Jennifer L.; Kingsolver, Joel G.
2013-01-01
The initial rise of fitness that occurs with increasing temperature is attributed to Arrhenius kinetics, in which rates of reaction increase exponentially with increasing temperature. Models based on Arrhenius typically assume single rate-limiting reaction(s) over some physiological temperature range for which all the rate-limiting enzymes are in 100% active conformation. We test this assumption using datasets for microbes that have measurements of fitness (intrinsic rate of population growth) at many temperatures and over a broad temperature range, and for diverse ectotherms that have measurements at fewer temperatures. When measurements are available at many temperatures, strictly Arrhenius kinetics is rejected over the physiological temperature range. However, over a narrower temperature range, we cannot reject strictly Arrhenius kinetics. The temperature range also affects estimates of the temperature dependence of fitness. These results indicate that Arrhenius kinetics only apply over a narrow range of temperatures for ectotherms, complicating attempts to identify general patterns of temperature dependence. PMID:20528477
Knies, Jennifer L; Kingsolver, Joel G
2010-08-01
The initial rise of fitness that occurs with increasing temperature is attributed to Arrhenius kinetics, in which rates of reaction increase exponentially with increasing temperature. Models based on Arrhenius typically assume single rate-limiting reactions over some physiological temperature range for which all the rate-limiting enzymes are in 100% active conformation. We test this assumption using data sets for microbes that have measurements of fitness (intrinsic rate of population growth) at many temperatures and over a broad temperature range and for diverse ectotherms that have measurements at fewer temperatures. When measurements are available at many temperatures, strictly Arrhenius kinetics are rejected over the physiological temperature range. However, over a narrower temperature range, we cannot reject strictly Arrhenius kinetics. The temperature range also affects estimates of the temperature dependence of fitness. These results indicate that Arrhenius kinetics only apply over a narrow range of temperatures for ectotherms, complicating attempts to identify general patterns of temperature dependence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Z; Nath, R
Purpose: To measure the energy dependence of TLD sensitivity in lowenergy photon beams with equivalent mono-energetic energy matching those of 103Pd, 125I and 131Cs brachytherapy sources. Methods: A Pantek DXT 300 x-ray unit (Precision X-ray, Branford, CT), with stable digital voltage control down to 20 kV, was used to establish three lowenergy photon beams with narrow energy spread and equivalent monoenergetic energies matching those of 103Pd, 125I and 131Cs brachytherapy sources. The low-energy x-ray beams and a reference 6 MV photon beam were calibrated according to the AAPM TG-61 and TG-51 protocols, respectively, using a parallel-plate low-energy chamber and amore » Farmer cylindrical chamber with NIST traceable calibration factors. The dose response of model TLD-100 micro-cubes (1×1×1 mm{sup 3}) in each beam was measured for five different batches of TLDs (each contained approximately 100 TLDs) that have different histories of irradiation and usage. Relative absorbed dose sensitivity was determined as the quotient of the slope of dose response for a beam-of-interest to that of the reference beam. Results: Equivalent mono-energetic photon energies of the low-energy beams established for 103Pd, 125I and 131Cs sources were 20.5, 27.5, and 30.1 keV, respectively. Each beam exhibited narrow spectral spread with energyhomogeneity index close to 90%. The relative absorbed-dose sensitivity was found to vary between different batches of TLD with maximum differences of up to 8%. The mean and standard deviation determined from the five TLD batches was 1.453 ± 0.026, 1.541 ± 0.035 and 1.529 ± 0.051 for the simulated 103P, 125I and 131Cs beams, respectively. Conclusion: Our measured relative absorbed-dose sensitivities are greater than the historically measured value of 1.41. We find that the relative absorbed-dose sensitivity of TLD in the 103P beam is approximately 5% lower than that of 125I and 131Cs beams. Comparison of our results with other studies will be presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chungbin, S; Fatyga, M
Purpose: To verify that a photon total body irradiation (TBI) calculation method scales properly from adult to pediatric dimensions and to determine TBI in-vivo dosimetry correction factors for diodes and optically stimulated luminescent dosimeters (OSLD's). Methods: TBI technique used is 400 SAD 18 MV opposed laterals with beam spoiler. Water bags are used to supplement narrower lateral dimensions for patient treatments. To verify that dose calculations scale properly with decreasing dimensions, CAX doses were measured and compared to calculations for different rectangular phantom geometries: (L=length(cm), H=height(cm), d=depth(cm)): L(30)xH(30) (d=3-25), L(30)xH(12)(d=2–20), L(13)xH(13) (d=5–13), L(30)x(H=10–40) d=15, L(30–150) x H(10) (d=15). In infantmore » geometry, measured off axis “leg” dose (L(30)xH(2.5–10.6), d=7)) was compared to CAX (“body” L(30)xH(10)(d=7) adjacent to “leg”). Entrance and exit doses were measured with surface diodes, diodes with buildup, OSLD's, as well as ion chambers for comparison. Correction factors ((ion chamber CAX dose)/(in vivo dose)) were calculated for surface diodes, diodes with buildup, OSLD's, and ion chamber. Results: All rectangular phantom measurements agree with calculated within 2.5%. For L(30)xH(30), L(30)xH(12), L(13)xH(13), L(30)x(H=10–40) and L(30–80)xH(10) agreement was within 1%. For the infant geometry, the ratio of leg dose to CAX varies from 0.956 (h=2.5) to 0.995 (h=10.6). The range of in-vivo dosimetry entrance+exit to CAX dose correction factors varied by dosimeter (diode: 0.883–1.015, surface diode: 1.008–1.214, ion chamber: 0.924–1.084, OSLD: 0.920–1.106). Conclusion: TBI calculations scaled properly to pediatric dimensions. In-vivo dosimetry with various detectors demonstrated similar trends with different magnitudes. OSLD measurements agreed well with ion chamber measurements.« less
Paradoxical Seizure Response to Phenytoin in an Epileptic Heroin Addict.
Vasagar, Brintha; Verma, Beni R; Dewberry, Robert G; Pula, Thaddeus
2015-06-01
Phenytoin has a narrow therapeutic window and seizures can occur at both ends of the spectrum. A 41-year-old man with a history of a seizure disorder and heroin addiction presented with dizziness following 2 generalized tonic-clonic seizures that occurred earlier that day. The patient had received a loading dose of phenytoin for seizures associated with a subtherapeutic level 5 days previously. Initial evaluation revealed an elevated phenytoin level of 32.6 mcg/mL and an opiate-positive toxicology screen. Levetiracetam was started on the day of presentation and phenytoin was held until the level returned to the therapeutic range. The patient's dizziness resolved and he had no additional seizures. Evaluation for reversible causes of seizure activity along with anticonvulsant administration is generally the standard of care for breakthrough seizures. Phenytoin blood levels, if supratherapeutic, may be at least partially responsible for breakthrough seizure activity; in this circumstance, holding phenytoin and temporarily adding another anticonvulsant may be indicated.
Hou, D X; Fukuda, M; Fujii, M; Fuke, Y
2000-12-20
Wasabi is a very popular pungent spice in Japan. This study examined the ability of 6-(methylsufinyl)hexyl isothiocyanate (6-MITC), an active principle of wasabi, to induce the cellular expression of nicotinamide adenine dinucleotide phosphate: quinone oxidoreductase (QR) in Hepa 1c1c7 cells. The cells were treated with various concentrations of 6-MITC, and were then assessed for cell growth, QR activity and QR mRNA expression. The induction of QR activity and QR mRNA expression was time- and dose-responsive over a narrow range of 0.1-5 microM, with declining induction at higher concentrations due to cell toxicity. Furthermore, transfection studies demonstrated that the induction of transcription of the QR gene by 6-MITC involved an antioxidant/electrophile-responsive element (ARE/EpRE) activation. Our results suggest a novel mechanism by which dietary wasabi 6-MITC may be implicated in cancer chemoprevention.
Massillon-J L, G; Cabrera-Santiago, A; Minniti, R; O'Brien, M; Soares, C G
2014-08-07
LiF:Mg,Ti, are widely used to estimate absorbed-dose received by patients during diagnostic or medical treatment. Conveniently, measurements are usually made in plastic phantoms. However, experimental conditions vary from one group to another and consequently, a lack of consensus data exists for the energy dependence of thermoluminescent (TL) response. This work investigated the energy dependence of TLD-100 TL-response and the effect of irradiating the dosimeters in different phantom materials for a broad range of energy photons in an attempt to understand the parameters that affect the discrepancies reported by various research groups. TLD-100s were exposed to 20-300 kV narrow x-ray spectra, (137)Cs and (60)Co photons. Measurements were performed in air, PMMA, wt1, polystyrene and TLDS as surrounding material. Total air-kerma values delivered were between 50 and 150 mGy for x-rays and 50 mGy for (137)Cs and (60)Co beams; each dosimeter was irradiated individually. Relative response, R, defined as the TL-response per air-kerma and relative efficiency, RE, described as the TL-response per absorbed-dose (obtained through Monte Carlo (MC) and analytically) were used to describe the TL-response. Both R and RE are normalized to the responses in a (60)Co beam. The results indicate that the use of different phantom materials affects the TL-response and this response varies with energy and material type. MC simulations reproduced qualitatively the experimental data: a) R increases, reaches a maximum at ~25 keV and decreases; b) RE decreases, down to a minimum at ~60 keV, increases to a maximum at ~150 keV and after decreases. Independent of the phantom materials, RE strongly depends on how the absorbed dose is evaluated and the discrepancies between RE evaluated analytically and by MC simulation are around 4% and 18%, dependent on the photon energy. The comparison between our results and that reported in the literature suggests that the discrepancy observed between different research groups appears to be most likely related to supralinearity effect, phantom materials, difference on the energy-spectra and geometry conditions during each experiment rather than parameters such as heating-rate or annealing procedure, which was supported by MC simulation. From the results obtained in this work and the strict analysis performed, we can conclude that for clinical applications of TLD-100, special attention must be taken when published data are used to convert TL calibration curve from (60)Co to low-energy photons. Otherwise, this can lead to incorrect results when later used to measure absorbed dose in human tissue.
Decreased airway narrowing and smooth muscle contraction in hyperresponsive pigs.
Turner, Debra J; Noble, Peter B; Lucas, Matthew P; Mitchell, Howard W
2002-10-01
Increased smooth muscle contractility or reduced smooth muscle mechanical loads could account for the excessive airway narrowing and hyperresponsiveness seen in asthma. These mechanisms were investigated by using an allergen-induced porcine model of airway hyperresponsiveness. Airway narrowing to electric field stimulation was measured in isolated bronchial segments, over a range of transmural pressures (0-20 cmH(2)O). Contractile responses to ACh were measured in bronchial segments and in isolated tracheal smooth muscle strips isolated from control and test (ovalbumin sensitized and challenged) pigs. Test airways narrowed less than controls (P < 0.0001). Test pigs showed reduced contractility to ACh, both in isolated bronchi (P < 0.01) and smooth muscle strips (P < 0.01). Thus isolated airways from pigs exhibiting airway hyperresponsiveness in vivo are hyporesponsive in vitro. The decreased narrowing in bronchi from hyperresponsive pigs may be related to decreased smooth muscle contractility. These data suggest that mechanisms external to the airway wall may be important to the hyperresponsive nature of sensitized lungs.
Relationship between relative lens position and appositional closure in eyes with narrow angles.
Otori, Yasumasa; Tomita, Yuki; Hamamoto, Ayumi; Fukui, Kanae; Usui, Shinichi; Tatebayashi, Misako
2011-03-01
To investigate the relationship between relative lens position (RLP) and appositional closure in eyes with narrow angles. Ultrasound biomicroscopy (UBM) was used to measure anterior chamber depth (ACD) and lens thickness (LT), and the IOLMaster to measure axial length (AL). The number of quadrants with appositional closure was assessed by UBM under dark conditions. The RLP was calculated thus: RLP = 10 × (ACD + 0.5 LT) /AL. This study comprised 30 consecutive patients (30 eyes) with narrow-angle eyes defined as Shaffer grade 2 or lower and without peripheral anterior synechiae (24 women, 6 men; mean age ± SD, 67.3 ± 10.4 years; range, 42-87 years). Under dark conditions, 66.7% of the eyes with narrow angles showed appositional closure in at least one quadrant. Of the various ocular biometric parameters, only the RLP significantly decreased with appositional closure in at least one quadrant (P = 0.005). A decrease in the RLP can be predictive of appositional closure for narrow-angle eyes under dark conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holland, O.W.; El-Ghor, M.K.; White, C.W.
1989-01-01
Damage nucleation/growth in single-crystal Si during ion irradiation is discussed. For MeV ions, the rate of growth as well as the damage morphology are shown to vary widely along the track of the ion. This is attributed to a change in the dominant, defect-related reactions as the ion penetrates the crystal. The nature of these reactions were elucidated by studying the interaction of MeV ions with different types of defects. The defects were introduced into the Si crystal prior to high-energy irradiation by self-ion implantation at a medium energy (100 keV). Varied damage morphologies were produced by implanting different ionmore » fluences. Electron microscopy and ion-channeling measurements, in conjunction with annealing studies, were used to characterize the damage. Subtle changes in the predamage morphology are shown to result in markedly different responses to the high-energy irradiation, ranging from complete annealing of the damage to rapid growth. These divergent responses occur over a narrow range of dose (2--3 /times/ 10/sup 14/ cm/sup /minus/2/) of the medium-energy ions; this range also marks a transition in the growth behavior of the damage during the predamage implantation. A model is proposed which accounts for these observations and provides insight into ion-induced growth of amorphous layers in Si and the role of the amorphous/crystalline interface in this process. 15 refs, 9 figs.« less
Effect of food on absorption of Dilantin Kapseals and Mylan extended phenytoin sodium capsules.
Wilder, B J; Leppik, I; Hietpas, T J; Cloyd, J C; Randinitis, E J; Cook, J
2001-08-28
Because of phenytoin's narrow therapeutic index and nonlinear pharmacokinetics, food-induced alterations in absorption may markedly influence drug concentrations and, in turn, safety and effectiveness. Potential food-associated differences between 100-mg Mylan (Mylan Pharmaceuticals) extended-release phenytoin sodium capsules and Parke-Davis 100-mg Dilantin Kapseals were examined. A single-dose, two-way crossover study was conducted in 24 healthy subjects to determine the effect of a high-fat meal on the pharmacokinetics of both formulations. Pharmacokinetic parameters were estimated by noncompartmental methods. The impact of switching products on steady-state phenytoin concentrations was investigated through simulation using pharmacokinetic data previously obtained from 30 epileptic patients. Based on AUC(0-infinity), bioavailability of the Mylan product administered with food was 13% lower than that observed with Dilantin Kapseals. Simulations of substituting the Mylan product for Dilantin suggested that the 13% decrease in bioavailability would result in a median 37% decrease (range 19 to 58%) in plasma phenytoin concentrations when the drug is given with food; in 46% of patients, phenytoin concentrations would likely fall below the therapeutic range of 10 to 20 mg/L. Simulations of substituting Dilantin for the Mylan product suggested that the 15% increase in bioavailability would result in a median 102% increase (range 24 to >150%) in plasma phenytoin concentrations, with 84% of patients having phenytoin concentrations above the therapeutic range. Results suggest that when taking phenytoin sodium with food, product switches may result in either side effects or loss of seizure control.
Sawers, Andrew; Hafner, Brian J
2018-05-08
Challenging clinical balance tests are needed to expose balance deficits in lower-limb prost-hesis users. This study examined whether narrowing beam-walking could overcome conceptual and practical limitations identified in fixed-width beam-walking. Cross-sectional. Unilateral lower-limb prosthesis users. Participants walked 10 times along a low, narrowing beam. Performance was quantified using the normalized distance walked. Heuristic rules were applied to determine whether the narrowing beam task was "too easy," "too hard," or "appropriately challenging" for each participant. Linear regression and Bland-Altman plots were used to determine whether combinations of the first 5 trials could predict participants' stable beam-walking performance. Forty unilateral lower-limb prosthesis users participated. Narrowing beam-walking was appropriately challenging for 98% of participants. Performance stabilized for 93% of participants within 5 trials, while 62% were stable across all trials. The mean of trials 3-5 accurately predicted stable performance. A clinical narrowing beam-walking test is likely to challenge a range of lower-limb prosthesis users, have minimal administrative burden, and exhibit no floor or ceiling effects. Narrowing beam-walking is therefore a clinically viable method to evaluate lower-limb prosthesis users' balance ability, but requires psychometric testing before it is used to assess fall risk.
Acquisition and visualization techniques for narrow spectral color imaging.
Neumann, László; García, Rafael; Basa, János; Hegedüs, Ramón
2013-06-01
This paper introduces a new approach in narrow-band imaging (NBI). Existing NBI techniques generate images by selecting discrete bands over the full visible spectrum or an even wider spectral range. In contrast, here we perform the sampling with filters covering a tight spectral window. This image acquisition method, named narrow spectral imaging, can be particularly useful when optical information is only available within a narrow spectral window, such as in the case of deep-water transmittance, which constitutes the principal motivation of this work. In this study we demonstrate the potential of the proposed photographic technique on nonunderwater scenes recorded under controlled conditions. To this end three multilayer narrow bandpass filters were employed, which transmit at 440, 456, and 470 nm bluish wavelengths, respectively. Since the differences among the images captured in such a narrow spectral window can be extremely small, both image acquisition and visualization require a novel approach. First, high-bit-depth images were acquired with multilayer narrow-band filters either placed in front of the illumination or mounted on the camera lens. Second, a color-mapping method is proposed, using which the input data can be transformed onto the entire display color gamut with a continuous and perceptually nearly uniform mapping, while ensuring optimally high information content for human perception.
Improving Control in a Joule-Thomson Refrigerator
NASA Technical Reports Server (NTRS)
Borders, James; Pearson, David; Prina, Mauro
2005-01-01
A report discusses a modified design of a Joule-Thomson (JT) refrigerator under development to be incorporated into scientific instrumentation aboard a spacecraft. In most other JT refrigerators (including common household refrigerators), the temperature of the evaporator (the cold stage) is kept within a desired narrow range by turning a compressor on and off as needed. This mode of control is inadequate for the present refrigerator because a JT-refrigerator compressor performs poorly when the flow from its evaporator varies substantially, and this refrigerator is required to maintain adequate cooling power. The proposed design modifications include changes in the arrangement of heat exchangers, addition of a clamp that would afford a controlled heat leak from a warmer to a cooler stage to smooth out temperature fluctuations in the cooler stage, and incorporation of a proportional + integral + derivative (PID) control system that would regulate the heat leak to maintain the temperature of the evaporator within a desired narrow range while keeping the amount of liquid in the evaporator within a very narrow range in order to optimize the performance of the compressor. Novelty lies in combining the temperature- and cooling-power-regulating controls into a single control system.
Precursor of superfluidity in a strongly interacting Fermi gas with negative effective range
NASA Astrophysics Data System (ADS)
Tajima, Hiroyuki
2018-04-01
We investigate theoretically the effects of pairing fluctuations in an ultracold Fermi gas near a Feshbach resonance with a negative effective range. By employing a many-body T -matrix theory with a coupled fermion-boson model, we show that the single-particle density of states exhibits the so-called pseudogap phenomenon, which is a precursor of superfluidity induced by strong pairing fluctuations. We clarify the region where strong pairing fluctuations play a crucial role in single-particle properties, from the broad-resonance region to the narrow-resonance limit at the divergent two-body scattering length. We also extrapolate the effects of pairing fluctuations to the positive-effective-range region from our results near the narrow Feshbach resonance. Results shown in this paper are relevant to the connection between ultracold Fermi gases and low-density neutron matter from the viewpoint of finite-effective-range corrections.
Narrow pH Range of Surface Water Bodies Receiving Pesticide Input in Europe.
Bundschuh, Mirco; Weyers, Arnd; Ebeling, Markus; Elsaesser, David; Schulz, Ralf
2016-01-01
Fate and toxicity of the active ingredients (AI's) of plant protection products in surface waters is often influenced by pH. Although a general range of pH values is reported in literature, an evaluation targeting aquatic ecosystems with documented AI inputs is lacking at the larger scale. Results show 95% of European surface waters (n = 3075) with a documented history of AI exposure fall within a rather narrow pH range, between 7.0 and 8.5. Spatial and temporal variability in the data may at least be partly explained by the calcareous characteristics of parental rock material, the affiliation of the sampling site to a freshwater ecoregion, and the photosynthetic activity of macrophytes (i.e., higher pH values with photosynthesis). Nonetheless, the documented pH range fits well with the standard pH of most ecotoxicological test guidelines, confirming the fate and ecotoxicity of AIs are usually adequately addressed.
Longitudinal waves in a perpendicular collisionless plasma shock. IV - Gradient B.
NASA Technical Reports Server (NTRS)
Gary, S. P.
1972-01-01
The consideration of elastic waves in a Vlasov plasma of unmagnetized ions and magnetized electrons undergoing E x B electron drift and gradient B drift, pursued in the earlier three parts, is brought to conclusion in this last part of the longitudinal wave study in a collisionless plasma shock. Detailed calculations of the effects of the beta sub e dimensionless parameter on the E x B electron drift instability are presented. It is shown that the range of propagation of the elastic waves about the perpendicular remains quite narrow, and that, for oblique propagation, the already narrow angular range of unstable waves is decreased by increases in the value of the beta sub e dimensionless parameter. Also, increases in wave number generally reduce the growth rate and the angular range of propagation.
Effects of the food additive, citric acid, on kidney cells of mice.
Chen, Xg; Lv, Qx; Liu, Ym; Deng, W
2015-01-01
Citric acid is a food additive that is widely used in the food and drink industry. We investigated the effects of citric acid injection on mouse kidney. Forty healthy mice were divided into four groups of 10 including one control group and three citric acid-treated groups. Low dose, middle dose and high dose groups were given doses of 120, 240 and 480 mg/kg of citric acid, respectively. On day 7, kidney tissues were collected for histological, biochemical and molecular biological examination. We observed shrinkage of glomeruli, widened urinary spaces and capillary congestion, narrowing of the tubule lumen, edema and cytoplasmic vacuolated tubule cells, and appearance of pyknotic nuclei. The relation between histopathological changes and citric acid was dose dependent. Compared to the control, T-SOD and GSH-Px activities in the treated groups decreased with increasing doses of citric acid, NOS activity tended to increase, and H2O2 and MDA contents gradually decreased, but the differences between any treated group and the control were not statistically significant. The apoptosis assay showed a dose-dependent increase of caspase-3 activity after administering citrate that was statistically significant. DNA ladder formation occurred after treatment with any dose of citric acid. We concluded that administration of citric acid may cause renal toxicity in mice.
Electronic characterization of defects in narrow gap semiconductors
NASA Technical Reports Server (NTRS)
Patterson, James D.
1993-01-01
The study of point defects in semiconductors has a long and honorable history. In particular, the detailed understanding of shallow defects in common semiconductors traces back to the classic work of Kohn and Luttinger. However, the study of defects in narrow gap semiconductors represents a much less clear story. Here, both shallow defects (caused by long range potentials) and deep defects (from short range potentials) are far from being completely understood. In this study, all results are calculational and our focus is on the chemical trend of deep levels in narrow gap semiconductors. We study substitutional (including antisite), interstitial and ideal vacancy defects. For substitutional and interstitial impurities, the efects of relaxation are included. For materials like Hg(1-x)Cd(x)Te, we study how the deep levels vary with x, of particular interest is what substitutional and interstitial atoms yield energy levels in the gap i.e. actually produce deep ionized levels. Also, since the main technique utilized is Green's functions, we include some summary of that method.
Swiercz, Miroslaw; Swiat, Maciej; Pawlak, Mikolaj; Weigele, John; Tarasewicz, Roman; Sobolewski, Andrzej; Hurst, Robert W; Mariak, Zenon D; Melhem, Elias R; Krejza, Jaroslaw
2010-01-01
The goal of the study was to compare performances of transcranial color-coded duplex sonography (TCCS) and transcranial Doppler sonography (TCD) in the diagnosis of the middle cerebral artery (MCA) narrowing in the same population of patients using statistical and nonstatistical intelligent models for data analysis. We prospectively collected data from 179 consecutive routine digital subtraction angiography (DSA) procedures performed in 111 patients (mean age 54.17+/-14.4 years; 59 women, 52 men) who underwent TCD and TCCS examinations simultaneously. Each patient was examined independently using both ultrasound techniques, 267 M1 segments of MCA were assessed and narrowings were classified as < or =50% and >50% lumen reduction. Diagnostic performance was estimated by two statistical and two artificial neural networks (ANN) classification methods. Separate models were constructed for the TCD and TCCS sonographic data, as well as for detection of "any narrowing" and "severe narrowing" of the MCA. Input for each classifier consisted of the peak-systolic, mean and end-diastolic velocities measured with each sonographic method; the output was MCA narrowing. Arterial narrowings less or equal 50% of lumen reduction were found in 55 and >50% narrowings in 26 out of 267 arteries, as indicated by DSA. In the category of "any narrowing" the rate of correct assignment by all models was 82% to 83% for TCCS and 79% to 81% for TCD. In the diagnosis of >50% narrowing the overall classification accuracy remained in the range of 89% to 90% for TCCS data and 90% to 91% for TCD data. For the diagnosis of any narrowing, the sensitivity of the TCCS was significantly higher than that of the TCD, while for diagnosis of >50% MCA narrowing, sensitivity of the TCCS was similar to sensitivity of the TCD. Our study showed that TCCS outperforms conventional TCD in detection of < or =50% MCA narrowing, whereas no significant difference in accuracy between both methods was found in the diagnosis of >50% MCA narrowing. (E-mail: jaroslaw.krejza@uphs.upenn.edu).
VKORC1 polymorphisms and warfarin maintenance dose in population of Sakha (Yakuts).
Chertovskikh, Y V; Malova, E U; Maksimova, N R; Popova, N V; Sychev, D A
2015-01-01
Vitamin K antagonists are effective in the prevention and treatment of thromboembolic disorders. Warfarin is one of the most widely prescribed vitamin K antagonists in the world [1, 2]. It has a narrow therapeutic range and a given dose may result in a large inter-individual variation of response. Insufficient dose may fail to prevent thromboembolism, while an overdose increases the risk of bleeding. Patient-specific factors (e.g., age, body size, race, concurrent diseases, and medications) explain some of the variability in warfarin dosage, but genetic factors influencing warfarin response explain a significantly higher proportion of this variability [3]. Molecular analysis of the gene that encodes the target enzyme vitamin K epoxide reductase complex 1 (VKORC1) strongly suggests that its genetic variations greatly affect the individual response to oral anticoagulants [4-7]. To evaluate effects of VKORC1 polymorphisms on warfarin dose excess anticoagulation (INR >4.0) in the population of Sakha (S) patients. 53 patients (29-women, 24-men) with atrial fibrillation (68%), congestive heart failure (60%), hypertension (49%) and cardiac valve replacement (26%) were recruited. The age range was 26-80 years, with a mean age of 62.87 ± 12.57 years.International normalized ratio and plasma warfarin concentrations were determined. Genotyping was carried out by RT-PCR (real-time PCR). The three genetic polymorphisms of the gene VKORC1 G3673A (rs9923231) were studied: normal (GG), heterozygous (GA) and homozygous (AA). Fisher exact probability test and chi-square test (with Yates correction) were applied to compare data among the AA and GG + GA groups; also Mann-Whitney test was used. The median maintenance daily dose of warfarin among AA carriers was 3.0 mg/day [1.25-7.5 mg], while in GG and GA patients it was 3.13 mg/day [1.88-7.92 mg]. The mean daily warfarin dosage was higher in GG and GA genotype carriers 4.05 mg/day (SD ± 1.7) than in patients with AA genotype 3.13 (SD ± 1.5). Differences are of borderline significance (p = 0.054). Of the 41 patients who required warfarin doses of less than 5 mg, 28 (63%) were found to be AA carriers and 14 (37%) were GG, GA carriers. Differences were not quite significant (p = 0.072). Among 31 homozygous polymorphism carriers 2 (4%) patients developed overanticoagulation (INR >4.0), while among 22 normal and heterozygous polymorphisms carriers only 3 (6%) patients developed overanticoagulation (INR >4.0). Differences were not statistically significant (p = 0.36). No significant association between VKORC1 polymorphisms and the frequency of excess anticoagulation (INR >4.0) was found. This may be explained by the number of cases included. AA polymorphisms compared to other polymorphisms shows borderline difference in the warfarin dose. The results can be used for the development of a pharmacogenetic-guided warfarin dosing algorithm.
Schwarze, Susanne; Schneider, Nils-Lasse; Reichl, Thomas; Dreyer, David; Lefeldt, Nele; Engels, Svenja; Baker, Neville; Hore, P. J.; Mouritsen, Henrik
2016-01-01
Magnetic compass orientation in night-migratory songbirds is embedded in the visual system and seems to be based on a light-dependent radical pair mechanism. Recent findings suggest that both broadband electromagnetic fields ranging from ~2 kHz to ~9 MHz and narrow-band fields at the so-called Larmor frequency for a free electron in the Earth’s magnetic field can disrupt this mechanism. However, due to local magnetic fields generated by nuclear spins, effects specific to the Larmor frequency are difficult to understand considering that the primary sensory molecule should be organic and probably a protein. We therefore constructed a purpose-built laboratory and tested the orientation capabilities of European robins in an electromagnetically silent environment, under the specific influence of four different oscillating narrow-band electromagnetic fields, at the Larmor frequency, double the Larmor frequency, 1.315 MHz or 50 Hz, and in the presence of broadband electromagnetic noise covering the range from ~2 kHz to ~9 MHz. Our results indicated that the magnetic compass orientation of European robins could not be disrupted by any of the relatively strong narrow-band electromagnetic fields employed here, but that the weak broadband field very efficiently disrupted their orientation. PMID:27047356
Impact of common cytostatic drugs on pollen fertility in higher plants.
Mišík, Miroslav; Kundi, Michael; Pichler, Clemens; Filipic, Metka; Rainer, Bernhard; Mišíková, Katarina; Nersesyan, Armen; Knasmueller, Siegfried
2016-08-01
Cytostatic drugs are among the most toxic chemicals which are produced. Many of them cause damage of the genetic material which may affect the fertility of higher organisms. To study the impact of the widely used anticancer drugs [cisplatin (CisPt), etoposide (Et), and 5-fluorouracil (5-FU)] on the reproduction of higher plants, pollen abortion experiments were conducted with species which belong to major plant families, namely with Tradescantia paludosa (Commelinaceae), Arabidopsis thaliana (Brassicaceae), Chelidonium majus (Papaveraceae), and Alisma plantago-aquatica (Alismataceae). All compounds increased the frequencies of abortive grains. The lowest effective doses were in general in a narrow range (i.e., 1 and 10 mg/kg of dry soil). The effects of the individual drugs were similar in T. paludosa, A. plantago-aquatica, and Ch. majus, while A. thaliana was consistently less sensitive. The highest abortion rate was obtained in most experiments with CisPt, followed by 5-FU and Et. Comparisons of the doses which caused effects in the present experiments in the different species with the predicted environment concentrations and with the levels of the cytostatics which were detected in hospital wastewaters show that the realistic environmental concentrations of the drugs are 4-6 orders of magnitude lower. Therefore, it is unlikely that these drugs affect the fertility of higher plants in aquatic and terrestrial ecosystems.
Pharmacogenetics of warfarin: challenges and opportunities
Ta Michael Lee, Ming; Klein, Teri E
2014-01-01
Since the introduction in the 1950s, warfarin has become the commonly used oral anticoagulant for the prevention of thromboembolism in patients with deep vein thrombosis, atrial fibrillation or prosthetic heart valve replacement. Warfarin is highly efficacious; however, achieving the desired anticoagulation is difficult because of its narrow therapeutic window and highly variable dose response among individuals. Bleeding is often associated with overdose of warfarin. There is overwhelming evidence that an individual's warfarin maintenance is associated with clinical factors and genetic variations, most notably polymorphisms in cytochrome P450 2C9 and vitamin K epoxide reductase subunit 1. Numerous dose-prediction algorithms incorporating both genetic and clinical factors have been developed and tested clinically. However, results from major clinical trials are not available yet. This review aims to provide an overview of the field of warfarin which includes information about the drug, genetics of warfarin dose requirements, dosing algorithms developed and the challenges for the clinical implementation of warfarin pharmacogenetics. PMID:23657428
Limited PCB antagonism of TCDD-induced malformations in mice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morrissey, R.E.; Harris, M.W.; Diliberto, J.J.
1992-01-01
Mice used to model induction of cleft palate and kidney malformations in offspring following maternal treatment with TCDD, were dosed on gestation day with hexachlorobiphenyl (HCB) and/or with tetrachlorodibenzo-p-dioxin (TCDD) to investigate the potential protective effects of HCB against TCDD-induced teratogenicity. At the doses used in the study, there was no effect of either compound on number of live or dead offspring. Fetal body weight was slightly decreased in all groups dosed with = or > 250 mg HCB/kg. HCB did not induce cleft palate at a dose of 1000 mg/kg, but did induce increases in hydronephrosis and hydroureter atmore » 500 and 1000 mg/kg. Combinations of HCB and TCDD decreased the incidence of cleft palate induced by TCDD alone, but only at doses of 15 microgram TCDD/kg combined with 125-500 mg HCB/kg. The window for antagonism of hydronephrosis (incidence and severity) appeared narrower (15 microgram TCDD/kg + 500 mg HCB/kg). HCB induced increases (3 fold) in EROD activity at doses of 500 and 1000 mg/kg, suggesting that the limited antagonism of TCDD teratogenicity by HCB would be consistent with control by Ah receptor. (Copyright (c) 1992 Elsevier Science Publishers B.V.)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geng, C; Nanjing University of Aeronautics and Astronautics, Nanjing; Daartz, J
Purpose: To evaluate the accuracy of dose calculations by analytical dose calculation methods (ADC) for small field proton therapy in a gantry based passive scattering facility. Methods: 50 patients with intra-cranial disease were evaluated in the study. Treatment plans followed standard prescription and optimization procedures of proton stereotactic radiosurgery. Dose distributions calculated with the Monte Carlo (MC) toolkit TOPAS were used to represent delivered treatments. The MC dose was first adjusted using the output factor (OF) applied clinically. This factor is determined from the field size and the prescribed range. We then introduced a normalization factor to measure the differencemore » in mean dose between the delivered dose (MC dose with OF) and the dose calculated by ADC for each beam. The normalization was determined by the mean dose of the center voxels of the target area. We compared delivered dose distributions and those calculated by ADC in terms of dose volume histogram parameters and beam range distributions. Results: The mean target dose for a whole treatment is generally within 5% comparing delivered dose (MC dose with OF) and ADC dose. However, the differences can be as great as 11% for shallow and small target treated with a thick range compensator. Applying the normalization factor to the MC dose with OF can reduce the mean dose difference to less than 3%. Considering range uncertainties, the generally applied margins (3.5% of the prescribed range + 1mm) to cover uncertainties in range might not be sufficient to guarantee tumor coverage. The range difference for R90 (90% distal dose falloff) is affected by multiple factors, such as the heterogeneity index. Conclusion: This study indicates insufficient accuracy calculating proton doses using ADC. Our results suggest that uncertainties of target doses are reduced using MC techniques, improving the dosimetric accuracy for proton stereotactic radiosurgery. The work was supported by NIH/NCI under CA U19 021239. CG was partially supported by the Chinese Scholarship Council (CSC) and the National Natural Science Foundation of China (Grant No. 11475087).« less
Discovery of a narrow line quasar
NASA Technical Reports Server (NTRS)
Stocke, J.; Liebert, J.; Maccacaro, T.; Griffiths, R. E.; Steiner, J. E.
1982-01-01
A stellar object is reported which, while having X-ray and optical luminosities typical of quasars, has narrow permitted and forbidden emission lines over the observed spectral range. The narrow-line spectrum is high-excitation, the Balmer lines seem to be recombinational, and a redder optical spectrum than that of most quasars is exhibited, despite detection as a weak radio source. The object does not conform to the relationships between H-beta parameters and X-ray flux previously claimed for a large sample of the active galactic nuclei. Because reddish quasars with narrow lines, such as the object identified, may not be found by the standard techniques for the discovery of quasars, the object may be a prototype of a new class of quasars analogous to high-luminosity Seyfert type 2 galaxies. It is suggested that these objects cannot comprise more than 10% of all quasars.
Dynamic film thickness between bubbles and wall in a narrow channel
NASA Astrophysics Data System (ADS)
Ito, Daisuke; Damsohn, Manuel; Prasser, Horst-Michael; Aritomi, Masanori
2011-09-01
The present paper describes a novel technique to characterize the behavior of the liquid film between gas bubbles and the wall in a narrow channel. The method is based on the electrical conductance. Two liquid film sensors are installed on both opposite walls in a narrow rectangular channel. The liquid film thickness underneath the gas bubbles is recorded by the first sensor, while the void fraction information is obtained by measuring the conductance between the pair of opposite sensors. Both measurements are taken on a large two-dimensional domain and with a high speed. This makes it possible to obtain the two-dimensional distribution of the dynamic liquid film between the bubbles and the wall. In this study, this method was applied to an air-water flow ranging from bubbly to churn regimes in the narrow channel with a gap width of 1.5 mm.
Novel narrow-host-range vectors for direct cloning of foreign DNA in Pseudomonas.
Boivin, R; Bellemare, G; Dion, P
1994-01-01
Narrow-host-range vectors, based on an indigenous replicon and containing a multiple cloning site, have been constructed in a Pseudomonas host capable of growth on unusual substrates. The new cloning vectors yield sufficient amounts of DNA for preparative purposes and belong to an incompatibility group different from that of the incP and incQ broad-host-range vectors. One of these vectors, named pDB47F, was used to clone, directly in Pseudomonas, DNA fragments from Agrobacterium, Pseudomonas, and Rhizobium. A clone containing Agrobacterium and KmR gene sequences was transformed with a higher efficiency than an RSF1010-derived vector (by as much as 1250-fold) in four out of five Pseudomonas strains tested. The considerable efficiency obtained with this system makes possible the direct cloning and phenotypic selection of foreign DNA in Pseudomonas.
Paugh, SW; Stocco, G; McCorkle, JR; Diouf, B; Crews, KR; Evans, WE
2013-01-01
Pharmacogenomics research is yielding molecular diagnostic tools that can be used to optimize the selection of medications and their doses for individual patients. Given the narrow therapeutic index of most anticancer agents and the serious consequences of undertreatment, cancer chemotherapy is a compelling therapeutic area for translation of pharmacogenomics to the clinic. This review addresses how inherited (germline) and acquired (somatic) sources of genome variability can alter the toxicity or efficacy of cancer chemotherapy. PMID:21796115
Space radiation risk limits and Earth-Moon-Mars environmental models
NASA Astrophysics Data System (ADS)
Cucinotta, Francis A.; Hu, Shaowen; Schwadron, Nathan A.; Kozarev, K.; Townsend, Lawrence W.; Kim, Myung-Hee Y.
2010-12-01
We review NASA's short-term and career radiation limits for astronauts and methods for their application to future exploration missions outside of low Earth orbit. Career limits are intended to restrict late occurring health effects and include a 3% risk of exposure-induced death from cancer and new limits for central nervous system and heart disease risks. Short-term dose limits are used to prevent in-flight radiation sickness or death through restriction of the doses to the blood forming organs and to prevent clinically significant cataracts or skin damage through lens and skin dose limits, respectively. Large uncertainties exist in estimating the health risks of space radiation, chiefly the understanding of the radiobiology of heavy ions and dose rate and dose protraction effects, and the limitations in human epidemiology data. To protect against these uncertainties NASA estimates the 95% confidence in the cancer risk projection intervals as part of astronaut flight readiness assessments and mission design. Accurate organ dose and particle spectra models are needed to ensure astronauts stay below radiation limits and to support the goal of narrowing the uncertainties in risk projections. Methodologies for evaluation of space environments, radiation quality, and organ doses to evaluate limits are discussed, and current projections for lunar and Mars missions are described.
Perfect narrow band absorber for sensing applications.
Luo, Shiwen; Zhao, Jun; Zuo, Duluo; Wang, Xinbing
2016-05-02
We design and numerically investigate a perfect narrow band absorber based on a metal-metal-dielectric-metal structure which consists of periodic metallic nanoribbon arrays. The absorber presents an ultra narrow absorption band of 1.11 nm with a nearly perfect absorption of over 99.9% in the infrared region. For oblique incidence, the absorber shows an absorption more than 95% for a wide range of incident angles from 0 to 50°. Structure parameters to the influence of the performance are investigated. The structure shows high sensing performance with a high sensitivity of 1170 nm/RIU and a large figure of merit of 1054. The proposed structure has great potential as a biosensor.
WE-AB-209-10: Optimizing the Delivery of Sequential Fluence Maps for Efficient VMAT Delivery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craft, D; Balvert, M
2016-06-15
Purpose: To develop an optimization model and solution approach for computing MLC leaf trajectories and dose rates for high quality matching of a set of optimized fluence maps to be delivered sequentially around a patient in a VMAT treatment. Methods: We formulate the fluence map matching problem as a nonlinear optimization problem where time is discretized but dose rates and leaf positions are continuous variables. For a given allotted time, which is allocated across the fluence maps based on the complexity of each fluence map, the optimization problem searches for the best leaf trajectories and dose rates such that themore » original fluence maps are closely recreated. Constraints include maximum leaf speed, maximum dose rate, and leaf collision avoidance, as well as the constraint that the ending leaf positions for one map are the starting leaf positions for the next map. The resulting model is non-convex but smooth, and therefore we solve it by local searches from a variety of starting positions. We improve solution time by a custom decomposition approach which allows us to decouple the rows of the fluence maps and solve each leaf pair individually. This decomposition also makes the problem easily parallelized. Results: We demonstrate method on a prostate case and a head-and-neck case and show that one can recreate fluence maps to high degree of fidelity in modest total delivery time (minutes). Conclusion: We present a VMAT sequencing method that reproduces optimal fluence maps by searching over a vast number of possible leaf trajectories. By varying the total allotted time given, this approach is the first of its kind to allow users to produce VMAT solutions that span the range of wide-field coarse VMAT deliveries to narrow-field high-MU sliding window-like approaches.« less
Kiliç, Mehtap Gülsün; Hoşten, Cetin; Demirci, Sahinde
2009-11-15
This paper attempts to compare electrocoagulation using aluminum anodes and stainless steel cathodes with conventional coagulation by aluminum sulfate dosing on aqueous suspensions of ultrafine quartz. Several key parameters affecting the efficiency of electrocoagulation and coagulation were investigated with laboratory scale experiments in search of optimal parameter values. Optimal values of the parameters were determined on the basis of the efficiency of turbidity removal from ultrafine quartz suspensions. The parameters investigated in the study were suspension pH, electrical potential, current density, electrocoagulation time, and aluminum dosage. A comparison between electrocoagulation and coagulation was made on the basis of total dissolved aluminum, revealing that electrocoagulation and coagulation were equally effective at the same aluminum dosage for the removal of quartz particles from suspensions. Coagulation, however, was more effective in a wider pH range (pH 6-9) than electrocoagulation which yielded optimum effectiveness in a relatively narrower pH range around 9, where, in both methods, these pH values corresponded to near-zero zeta potentials of quartz particles. Furthermore, experimental results confirmed that electrocoagulation could display some pH buffering capacity. The kinetics of electrocoagulation was very fast (<10 min) in approaching a residual turbidity, which could be modeled with a second-order rate equation.
Yamasaki, Kanji; Sawaki, Masakuni; Ohta, Ryo; Okuda, Hirokazu; Katayama, Seiichi; Yamada, Tomoya; Ohta, Takafumi; Kosaka, Tadashi; Owens, William
2003-12-01
The Organisation for Economic Co-operation and Development has initiated the development of new guidelines for the screening and testing of potential endocrine disruptors. The Hershberger assay is one of the assays selected for validation based on the need for in vivo screening to detect androgen agonists or antagonists by measuring the response of five sex accessory organs and tissues of castrated juvenile male rats: the ventral prostate, the seminal vesicles with coagulating glands, the levator ani and bulbocavernosus muscle complex, the Cowper's glands, and the glans penis. The phase 1 feasibility demonstration stage of the Hershberger validation program has been successfully completed with a single androgen agonist and a single antagonist as reference substances. The phase 2 validation program employs a range of additional androgen agonists and antagonists as well as 5alpha-reductase inhibitors. Seven Japanese laboratories have contributed phase 2 validation studies of the Hershberger assay using methyltestosterone, vinclozolin, and 2,2-bis (4-chlorophenyl)-1,1-dichloroethylene (p,p'-DDE). The methyltestosterone doses were 0, 0.05, 0.5, 5, and 50 mg/kg/day, and the vinclozolin and p,p'-DDE doses were 0, 3, 10, 30, and 100 mg/kg/day. All chemicals were orally administered by gavage for 10 consecutive days. In the antagonist version of the assay using vinclozolin and p,p'-DDE, 0.2 mg/kg/day of testosterone propionate was coadministered by subcutaneous injection. All five accessory sex preproductive organs and tissues consistently responded with statistically significant changes in weight within a narrow window. Therefore, the Japanese studies support the Hershberger assay as a reliable and reproducible screening assay for the detection of androgen agonistic and antagonistic effects.
Chen, W-Y; Lee, C-Y; Lin, P-Y; Hsieh, C-E; Ko, C-J; Lin, K-H; Lin, C-C; Ming, Y-Z; Chen, Y-L
2017-03-01
Studies have shown that arecoline, the major alkaloid component of betel nuts, alters the activity of enzymes in the cytochrome P450 (CYP-450) family. Tacrolimus, an immunosuppressant that protects against organ rejection in transplant recipients, not only is mainly metabolized by CYP3A enzymes but also has a narrow therapeutic range. We aimed to investigate whether dose-adjusted blood trough levels of tacrolimus differed over time between betel nut-chewing and non-betel nut-chewing liver transplant recipients. In this retrospective case-control study, 14 active betel nut-using liver recipients were matched at a 1:2 ratio to 28 non-betel nut-using liver recipients by sex, age, graft source, duration of follow-up after liver transplantation, and estimated glomerular filtration rate. Differences in liver function index, renal function index, and dose-adjusted blood trough levels of tacrolimus over an 18-month period were compared between the 2 groups by using the Generalized Estimating Equation approach. Dose-adjusted blood trough levels of tacrolimus tended to be significantly (P = .04) lower in betel nut chewers (mean = 0.81, medium = 0.7, 95% confidence interval [CI] = 0.73 to 0.90) than in nonchewers (mean = 1.12, medium = 0.88, 95% CI = 1.03 to 1.22) during the 18-month study period. However, there was no significant difference in renal and liver function index between the 2 groups. Liver transplant recipients receiving tacrolimus tend to have lower blood trough levels of the drug over time if they chew betel nuts. Copyright © 2016 Elsevier Inc. All rights reserved.
Acetylcholinesterase inhibition and locomotor function after motor-sensory cortex impact injury.
Holschneider, Daniel P; Guo, Yumei; Roch, Margareth; Norman, Keith M; Scremin, Oscar U
2011-09-01
Traumatic brain injury (TBI) induces transient or persistent dysfunction of gait and balance. Enhancement of cholinergic transmission has been reported to accelerate recovery of cognitive function after TBI, but the effects of this intervention on locomotor activity remain largely unexplored. The hypothesis that enhancement of cholinergic function by inhibition of acetylcholinesterase (AChE) improves locomotion following TBI was tested in Sprague-Dawley male rats after a unilateral controlled cortical impact (CCI) injury of the motor-sensory cortex. Locomotion was tested by time to fall on the constant speed and accelerating Rotarod, placement errors and time to cross while walking through a horizontal ladder, activity monitoring in the home cages, and rearing behavior. Assessments were performed the 1st and 2nd day and the 1st, 2nd, and 3rd week after TBI. The AChE inhibitor physostigmine hemisulfate (PHY) was administered continuously via osmotic minipumps implanted subcutaneously at the rates of 1.6-12.8 μmol/kg/day. All measures of locomotion were impaired by TBI and recovered to initial levels between 1 and 3 weeks post-TBI, with the exception of the maximum speed achievable on the accelerating Rotarod, as well as rearing in the open field. PHY improved performance in the accelerating Rotarod at 1.6 and 3.2 μmol/kg/day (AChE activity 95 and 78% of control, respectively), however, higher doses induced progressive deterioration. No effect or worsening of outcomes was observed at all PHY doses for home cage activity, rearing, and horizontal ladder walking. Potential benefits of cholinesterase inhibition on locomotor function have to be weighed against the evidence of the narrow range of useful doses.
The electrospray and its application to targeted drug inhalation.
Gomez, Alessandro
2002-12-01
This review explains the fundamentals of electrostatic spray (electrospray) atomization, with emphasis on operation in the so called cone-jet mode, which produces droplets with a very narrow size distribution. Since the control of droplet size is key to maximizing distal lung deposition, the electrospray should be well-suited to targeted drug inhalation. Electrospray droplets are a few micrometers in diameter, but they originate from a much larger nozzle, which allows nebulization of suspensions without clogging. Also discussed are: the physical principles of the break-up of the liquid ligament; droplet dispersion by Coulombic forces; and the most important scaling law linking the droplet size to liquid flow rate and liquid physical properties. The effects of the most critical of those properties may result in some restrictions on drug formulation. Droplets produced by electrospray are electrically charged, so to prevent electrostatic image forces from causing upper respiratory tract deposition. The charge is neutralized by generating a corona discharge of opposite polarity. Briefly discussed are the main differences between the laboratory systems (with which the electrospray has been quantitatively characterized during research in the past 10 years) and commercial electrospray inhalers under development at BattellePharma. Some remarkable miniaturization has incorporated liquid pump, power supply, breath activation, and dose counter into a palm-size portable device. The maximum flow rates dispersed from these devices are in the range of 8-16 microL/s, which makes them suitable for practical drug inhalation therapy. Fabrication is economically competitive with inexpensive nebulizers. Dramatic improvements in respirable dose efficiency (up to 78% by comparison with commercial metered-dose inhalers and dry powder inhalers) should ensure the commercialization of this promising technology for targeted drug inhalation.
Yamasaki, Kanji; Sawaki, Masakuni; Ohta, Ryo; Okuda, Hirokazu; Katayama, Seiichi; Yamada, Tomoya; Ohta, Takafumi; Kosaka, Tadashi; Owens, William
2003-01-01
The Organisation for Economic Co-operation and Development has initiated the development of new guidelines for the screening and testing of potential endocrine disruptors. The Hershberger assay is one of the assays selected for validation based on the need for in vivo screening to detect androgen agonists or antagonists by measuring the response of five sex accessory organs and tissues of castrated juvenile male rats: the ventral prostate, the seminal vesicles with coagulating glands, the levator ani and bulbocavernosus muscle complex, the Cowper's glands, and the glans penis. The phase 1 feasibility demonstration stage of the Hershberger validation program has been successfully completed with a single androgen agonist and a single antagonist as reference substances. The phase 2 validation program employs a range of additional androgen agonists and antagonists as well as 5alpha-reductase inhibitors. Seven Japanese laboratories have contributed phase 2 validation studies of the Hershberger assay using methyltestosterone, vinclozolin, and 2,2-bis (4-chlorophenyl)-1,1-dichloroethylene (p,p'-DDE). The methyltestosterone doses were 0, 0.05, 0.5, 5, and 50 mg/kg/day, and the vinclozolin and p,p'-DDE doses were 0, 3, 10, 30, and 100 mg/kg/day. All chemicals were orally administered by gavage for 10 consecutive days. In the antagonist version of the assay using vinclozolin and p,p'-DDE, 0.2 mg/kg/day of testosterone propionate was coadministered by subcutaneous injection. All five accessory sex preproductive organs and tissues consistently responded with statistically significant changes in weight within a narrow window. Therefore, the Japanese studies support the Hershberger assay as a reliable and reproducible screening assay for the detection of androgen agonistic and antagonistic effects. PMID:14644666
Yang, Mina; Choi, Rihwa; Kim, June Soo; On, Young Keun; Bang, Oh Young; Cho, Hyun-Jung; Lee, Soo-Youn
2016-12-01
The purpose of this study was to evaluate the performance of 16 previously published warfarin dosing algorithms in Korean patients. The 16 algorithms were selected through a literature search and evaluated using a cohort of 310 Korean patients with atrial fibrillation or cerebral infarction who were receiving warfarin therapy. A large interindividual variation (up to 11-fold) in warfarin dose was observed (median, 25 mg/wk; range, 7-77 mg/wk). Estimated dose and actual maintenance dose correlated well overall (r range, 0.52-0.73). Mean absolute error (MAE) of the 16 algorithms ranged from -1.2 to -20.1 mg/wk. The percentage of patients whose estimated dose fell within 20% of the actual dose ranged from 1.0% to 49%. All algorithms showed poor accuracy with increased MAE in a higher dose range. Performance of the dosing algorithms was worse in patients with VKORC1 1173TC or CC than in total (r range, 0.38-0.61 vs 0.52-0.73; MAE range, -2.6 to -28.0 mg/wk vs -1.2 to -20.1 mg/wk). The algorithms had comparable prediction abilities but showed limited accuracy depending on ethnicity, warfarin dose, and VKORC1 genotype. Further studies are needed to develop genotype-guided warfarin dosing algorithms with greater accuracy in the Korean population. Copyright © 2016 Elsevier HS Journals, Inc. All rights reserved.
Challenges of stroke prevention in patients with atrial fibrillation in clinical practice.
Hobbs, F D Richard; Leach, I
2011-09-01
Strokes and transient ischaemic attacks in patients with atrial fibrillation (AF) can be largely prevented. Risk stratification and appropriate prophylactic regimens help to alleviate the burden of AF-related thromboembolism. Guidelines recommend routine anticoagulation with oral vitamin K antagonists (VKAs) for patients at moderate-to-high risk of stroke, and acetylsalicylic acid (ASA) for those at low risk of stroke. ASA is less effective at reducing the risk of stroke than VKAs; however, ASA does not require monitoring or dose adjustment. Trials of anticoagulants show consistent benefits of oral VKAs for primary and secondary stroke prevention in patients with AF. Nevertheless, VKAs do require frequent coagulation monitoring and dose adjustment because of their variable dose-response profile, narrow therapeutic window, increased risk for bleeding complications and numerous food and drug interactions. This review aims to provide an overview of the clinical challenges of anticoagulant therapy for the prevention of stroke in patients with AF.
Nelson, Anita L
2017-08-01
A new five-year low dose, smaller-framed, levonorgestrel-releasing intrauterine contraceptive system (LNG-IUS 12) has been introduced to complement the currently available systems. Areas Covered: This article will provide an overview of this new intrauterine system - its composition and its mechanisms of action as well as the results of the Phase II and III clinical trials of its efficacy, safety and tolerability. Expert Commentary: This new LNG-IUS 12 provides five-year contraceptive protection a pregnancy rate (less than 1%) in first year of use, which puts it into the top tier with the existing LNG-IUS 20 products; however, the LNG-IUS 12 does not have the high rates of amenorrhea often seen with the higher dose devices. On the other hand, this new IUD shares the smaller frame and narrower insertion tube with the lower dose LNG-IUS 8, but offers longer effective life.
Weber, Damien C; Ares, Carmen; Lomax, Antony J; Kurtz, John M
2006-01-01
Postoperative radiation therapy substantially decreases local relapse and moderately reduces breast cancer mortality, but can be associated with increased late mortality due to cardiovascular morbidity and secondary malignancies. Sophistication of breast irradiation techniques, including conformal radiotherapy and intensity modulated radiation therapy, has been shown to markedly reduce cardiac and lung irradiation. The delivery of more conformal treatment can also be achieved with particle beam therapy using protons. Protons have superior dose distributional qualities compared to photons, as dose deposition occurs in a modulated narrow zone, called the Bragg peak. As a result, further dose optimization in breast cancer treatment can be reasonably expected with protons. In this review, we outline the potential indications and benefits of breast cancer radiotherapy with protons. Comparative planning studies and preliminary clinical data are detailed and future developments are considered. PMID:16857055
Phase behavior of mixtures of DPPC and POPG.
Wiedmann, T; Salmon, A; Wong, V
1993-04-07
The phase relation of dipalmitoylphosphatidylcholine (DPPC) and 1-palmitoyl-2-oleoyl-phosphatidylglycerol (POPG) has been determined by measurement of the endothermic transitions of mixtures of DPPC and POPG in 100 mM NaCl, 50 mM PIPES (pH 7.0). With the use of differential scanning calorimetry, the gel-liquid crystalline phase transitions of pure POPG and DPPC were estimated to be 274 K and 315.8 K, respectively. With mixtures, there was considerable broadening of the endotherms, but there was no evidence of immiscibility. At high and low mole fractions of DPPC, the observed transition regions are not different from that calculated assuming ideal behavior. However in the central region of the phase diagram, there were deviations from both the ideal liquidus and solidus curves. The chemical shift anisotropy of the 13C-labelled carbonyl carbon of pure DPPC was determined as a function of temperature. At 298 K, a broad peak characteristic of axially symmetric motional averaging of the shielding tensor was observed. At a temperature of 300 K, a narrow peak at 173 ppm was superimposed upon the broad peak. The magnitude of the narrow resonance increased with temperature over the range of 300 to 315 K with the spectrum obtained at the latter point almost completely devoid of any broad features. Spectra obtained with a 9:1 mole ratio of DPPC/POPG was very similar to that obtained with pure DPPC. However, with increasing amounts of POPG, both the temperature at which the narrow resonance appeared and the temperature at which only a narrow resonance was observed were reduced. Over the range of 0 to 50 mol % POPG, there was no major change in the width or shape of the spectra which contained only a broad or narrow resonance. Also for mol % of POPG of 20% and less, there was agreement between the temperature at which only the narrow component was observed and the completion of the main phase transition based on the DSC scans. However, at the two higher mol % of 33 and 50%, the temperature at which only the narrow component was observed was lower than the temperature established for the completion of the main phase transition.
Shapiro, Stuart L
2017-05-15
We have performed magnetohydrodynamic simulations in general relativity of binary neutron star and binary black hole-neutron star mergers, as well as the magnetorotational collapse of supermassive stars. In many cases the outcome is a spinnng black hole (BH) immersed in a magnetized disk, with a jet emanating from the poles of the BH. While their formation scenarios differ and their BH masses, as well as their disk masses, densities, and magnetic field strengths, vary by orders of magnitude, these features conspire to generate jet Poynting luminosities that all lie in the same, narrow range of ~10 52±1 erg s -1 . A similar result applies to their BH accretion rates upon jet launch, which is ~0.1-10 M ⊙ s -1 . We provide a simple model that explains these unanticipated findings. Interestingly, these luminosities reside in the same narrow range characterizing the observed luminosity distributions of over 400 short and long GRBs with distances inferred from spectroscopic redshifts or host galaxies. This result, together with the GRB lifetimes predicted by the model, supports the belief that a compact binary merger is the progenitor of an SGRB, while a massive, stellar magnetorotational collapse is the progenitor of an LGRB.
Shapiro, Stuart L.
2018-01-01
We have performed magnetohydrodynamic simulations in general relativity of binary neutron star and binary black hole-neutron star mergers, as well as the magnetorotational collapse of supermassive stars. In many cases the outcome is a spinnng black hole (BH) immersed in a magnetized disk, with a jet emanating from the poles of the BH. While their formation scenarios differ and their BH masses, as well as their disk masses, densities, and magnetic field strengths, vary by orders of magnitude, these features conspire to generate jet Poynting luminosities that all lie in the same, narrow range of ~1052±1 erg s−1. A similar result applies to their BH accretion rates upon jet launch, which is ~0.1–10 M⊙ s−1. We provide a simple model that explains these unanticipated findings. Interestingly, these luminosities reside in the same narrow range characterizing the observed luminosity distributions of over 400 short and long GRBs with distances inferred from spectroscopic redshifts or host galaxies. This result, together with the GRB lifetimes predicted by the model, supports the belief that a compact binary merger is the progenitor of an SGRB, while a massive, stellar magnetorotational collapse is the progenitor of an LGRB. PMID:29881790
Improved pulse laser ranging algorithm based on high speed sampling
NASA Astrophysics Data System (ADS)
Gao, Xuan-yi; Qian, Rui-hai; Zhang, Yan-mei; Li, Huan; Guo, Hai-chao; He, Shi-jie; Guo, Xiao-kang
2016-10-01
Narrow pulse laser ranging achieves long-range target detection using laser pulse with low divergent beams. Pulse laser ranging is widely used in military, industrial, civil, engineering and transportation field. In this paper, an improved narrow pulse laser ranging algorithm is studied based on the high speed sampling. Firstly, theoretical simulation models have been built and analyzed including the laser emission and pulse laser ranging algorithm. An improved pulse ranging algorithm is developed. This new algorithm combines the matched filter algorithm and the constant fraction discrimination (CFD) algorithm. After the algorithm simulation, a laser ranging hardware system is set up to implement the improved algorithm. The laser ranging hardware system includes a laser diode, a laser detector and a high sample rate data logging circuit. Subsequently, using Verilog HDL language, the improved algorithm is implemented in the FPGA chip based on fusion of the matched filter algorithm and the CFD algorithm. Finally, the laser ranging experiment is carried out to test the improved algorithm ranging performance comparing to the matched filter algorithm and the CFD algorithm using the laser ranging hardware system. The test analysis result demonstrates that the laser ranging hardware system realized the high speed processing and high speed sampling data transmission. The algorithm analysis result presents that the improved algorithm achieves 0.3m distance ranging precision. The improved algorithm analysis result meets the expected effect, which is consistent with the theoretical simulation.
Shielding properties of lead-free protective clothing and their impact on radiation doses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schlattl, Helmut; Zankl, Maria; Eder, Heinrich
2007-11-15
The shielding properties of two different lead-free materials--tin and a compound of 80% tin and 20% bismuth--for protective clothing are compared with those of lead for three typical x-ray spectra generated at tube voltages of 60, 75, and 120 kV. Three different quantities were used to compare the shielding capability of the different materials: (1) Air-kerma attenuation factors in narrow-beam geometry, (2) air-kerma attenuation factors in broad-beam geometry, and (3) ratios of organ and effective doses in the human body for a whole-body irradiation with a parallel beam directed frontally at the body. The thicknesses of tin (0.45 mm) andmore » the tin/bismuth compound (0.41 mm) to be compared against lead correspond to a lead equivalence value of 0.35 mm for the 75 kV spectrum. The narrow-beam attenuation factors for 0.45 mm tin are 54% and 32% lower than those for 0.35 mm lead for 60 and 120 kV; those for 0.41 mm tin/bismuth are 12% and 32% lower, respectively. The decrease of the broad-beam air-kerma attenuation factors compared to lead is 74%, 46%, and 41% for tin and 42%, 26%, and 33% for tin/bismuth and the spectra at 60, 75, and 120 kV, respectively. Therefore, it is recommended that the characterization of the shielding potential of a material should be done by measurements in broad-beam geometry. Since the secondary radiation that is mainly responsible for the shielding reduction in broad-beam geometry is of low penetrability, only more superficially located organs receive significantly enhanced doses. The increase for the dose to the glandular breast tissue (female) compared to being shielded by lead is 143%, 37%, and 45% when shielded by tin, and 35%, 15%, and 39% when shielded by tin/bismuth for 60, 75, and 120 kV, respectively. The effective dose rises by 60%, 6%, and 38% for tin, and 14%, 3% and, 35% for tin/bismuth shielding, respectively.« less
Nutritive quality and protein production from grain legumes in a boreal climate.
Lizarazo, Clara I; Lampi, Anna-Maija; Liu, Jingwei; Sontag-Strohm, Tuula; Piironen, Vieno; Stoddard, Frederick L
2015-08-15
Boreal cropping systems are heavily focused on the production of small-grain cereals; to improve their resilience to climate change and to achieve food and feed security, diversification is needed. This study investigated the potential of faba bean, narrow-leafed lupin and lentil as protein crops in southern Finland, where faba bean is traditional but the other two are novel. Early cultivars of narrow-leafed lupin and lentil matured adequately. Protein concentration in faba bean was, at 32%, higher than the world average of 29%, while those of narrow-leafed lupin and lentil were close to their world averages. Protein yields decreased in the order faba bean > narrow-leafed lupin > lentil. Lipid content of faba bean and lentil was about 1.2% and that of narrow-leafed lupin about 5.5%, and fatty acid composition was largely oleic and linoleic in all three species. Both lentil and narrow-leafed lupin can be added to the range of feed and food crops produced at high latitudes in Europe. While faba bean produces the greatest protein yield and lysine concentration, the higher sulfur amino acid concentration in lupin, its oil content and its adaptation to acid, sandy soils not suitable for faba bean make it an attractive alternative. © 2014 Society of Chemical Industry.
Lockard, Laura; Rowe, Christopher L; Heyes, Andrew
2013-04-01
Selenium (Se) is an essential micronutrient with a narrow therapeutic concentration range. The relative toxicity of Se increases as it is biotransformed into organic compounds, primarily selenomethionine (SeMet), within the aquatic food chain. Effects of aquatic Se contamination are well quantified for many freshwater fish and aquatic bird species, but impacts on amphibians are not well known. This study investigated the responses of larval Cope's gray tree frogs (Hyla chrysoscelis) fed a diet enriched with one of two concentrations of SeMet (50.1 and 489.9 μg Se g(-1) dw [low and high groups, respectively]) by way of a food-limited (ration) or ad libitum (ad lib) feeding regimen. The high dose caused 100 % mortality during the larval period independent of resource provision levels. Regardless of feeding regimen, the low dose decreased larval survival and successful metamorphosis relative to control treatments. The low dose also induced rear limb deformities in ≤73 % of individuals initiating metamorphosis. Providing low-dose food by way of a rationed feeding regimen decreased observed toxicity, likely because of decreased dietary exposure to SeMet relative to the low ad lib treatment. Individuals from the low ration treatment had decreased wet mass at initiation and completion of metamorphic climax (Gosner stages 42 through 46) compared with those from the control ad lib treatment, indicating that resource limitation combined with Se exposure might negatively affect energy stores after metamorphosis. However, lipid content analyses of recently metamorphosed individuals did not reveal any influence of treatment or resource provision on energy stored as lipids. The mean tissue Se concentration of individuals that received the low dose and completed metamorphosis was significantly greater than that of control ad lib or ration individuals at the same developmental stage. This study demonstrates that larval exposure to dietary SeMet can decrease growth and survival and induce deformities in a developing amphibian. Furthermore, retention of Se body burdens through metamorphosis suggests that surviving individuals can transport Se accumulated from contaminated aquatic environments into terrestrial food webs.
Determining harmful levels of contaminants for a wide range of species is limited by available toxicological data. Ecological risk assessments typically depend on empirical data from only a few species that represent a narrow range of the life history spectrum. Extrapolation mo...
Application of Methods of Numerical Analysis to Physical and Engineering Data.
1980-10-15
directed algorithm would seem to be called for. However, 1(0) is itself a random process, making its gradient too unreliable for such a sensitive algorithm...radiation energy on the detector . Active laser systems, on the other hand, have created now the possibility for extremely narrow path band systems...emitted by the earth and its atmosphere. The broad spectral range was selected so that the field of view of the detector could be narrowed to obtain
Wilson, Uzma S.; Kaf, Wafaa A.; Danesh, Ali A.; Lichtenhan, Jeffery T.
2016-01-01
Objective To determine the clinical utility of narrow-band chirp evoked 40-Hz sinusoidal auditory steady state responses (s-ASSR) in the assessment of low-frequency hearing in noisy participants. Design Tone bursts and narrow-band chirps were used to respectively evoke auditory brainstem responses (tb-ABR) and 40-Hz s-ASSR thresholds with the Kalman-weighted filtering technique and were compared to behavioral thresholds at 500, 2000, and 4000 Hz. A repeated measure ANOVA and post-hoc t-tests, and simple regression analyses were performed for each of the three stimulus frequencies. Study Sample Thirty young adults aged 18–25 with normal hearing participated in this study. Results When 4000 equivalent responses averages were used, the range of mean s-ASSR thresholds from 500, 2000, and 4000 Hz were 17–22 dB lower (better) than when 2000 averages were used. The range of mean tb-ABR thresholds were lower by 11–15 dB for 2000 and 4000 Hz when twice as many equivalent response averages were used, while mean tb-ABR thresholds for 500 Hz were indistinguishable regardless of additional response averaging Conclusion Narrow band chirp evoked 40-Hz s-ASSR requires a ~15 dB smaller correction factor than tb-ABR for estimating low-frequency auditory threshold in noisy participants when adequate response averaging is used. PMID:26795555
Band gap narrowing in BaTiO{sub 3} nanoparticles facilitated by multiple mechanisms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramakanth, S.; James Raju, K. C., E-mail: kcjrsp@uohyd.ernet.in; School of Physics, University of Hyderabad, Hyderabad 500046
2014-05-07
In the present work, BaTiO{sub 3} nanoparticles of four different size ranges were prepared by sol-gel method. The optical band gap of these particles at some size ranges has come down to 2.53 eV from 3.2 eV, resulting in substantial increase in optical absorption by these ferroelectric nanoparticles making them potential candidates for light energy harvesting. XRD results show the presence of higher compressive strain in 23 nm and 54 nm size particles, they exhibit a higher band gap narrowing, whereas tensile strain is observed in 31 nm and 34 nm particles, and they do not show the marginal band gap narrowing. The 23 nm and 54 nmmore » particles also show a coupling of free carriers to phonons by increasing the intensity of LO phonon mode at 715 cm{sup −1}. The higher surface charge density is expected in case of enhanced surface optical Raman modes (638 cm{sup −1}) contained in 31 and 34 nm size particles. In addition to this, the red shift in an LO mode Raman spectral line at 305 cm{sup −1} with decrease in particle size depicts the presence of phonon confinement in it. The enhanced optical absorption in 23 nm and 54 nm size particles with a narrowed band gap of 3 eV and 2.53 eV is due to exchange correlation interactions between the carriers present in these particles. In 31 nm and 34 nm range particles, the absorption got bleached exhibiting increased band gaps of 3.08 eV and 3.2 eV, respectively. It is due to filling up of conduction band resulting from weakening of exchange correlation interactions between the charge carriers. Hence, it is concluded that the band gap narrowing in the nanoparticles of average size 23 nm/54 nm is a consequence of multiple effects like strain, electron-phonon interaction, and exchange correlation interactions between the carriers which is subdued in some other size ranges like 31 nm/34 nm.« less
Taylor, Carolyn W; Wang, Zhe; Macaulay, Elizabeth; Jagsi, Reshma; Duane, Frances; Darby, Sarah C
2015-11-15
Breast cancer radiation therapy cures many women, but where the heart is exposed, it can cause heart disease. We report a systematic review of heart doses from breast cancer radiation therapy that were published during 2003 to 2013. Eligible studies were those reporting whole-heart dose (ie, dose averaged over the whole heart). Analyses considered the arithmetic mean of the whole-heart doses for the CT plans for each regimen in each study. We termed this "mean heart dose." In left-sided breast cancer, mean heart dose averaged over all 398 regimens reported in 149 studies from 28 countries was 5.4 Gy (range, <0.1-28.6 Gy). In regimens that did not include the internal mammary chain (IMC), average mean heart dose was 4.2 Gy and varied with the target tissues irradiated. The lowest average mean heart doses were from tangential radiation therapy with either breathing control (1.3 Gy; range, 0.4-2.5 Gy) or treatment in the lateral decubitus position (1.2 Gy; range, 0.8-1.7 Gy), or from proton radiation therapy (0.5 Gy; range, 0.1-0.8 Gy). For intensity modulated radiation therapy mean heart dose was 5.6 Gy (range, <0.1-23.0 Gy). Where the IMC was irradiated, average mean heart dose was around 8 Gy and varied little according to which other targets were irradiated. Proton radiation therapy delivered the lowest average mean heart dose (2.6 Gy, range, 1.0-6.0 Gy), and tangential radiation therapy with a separate IMC field the highest (9.2 Gy, range, 1.9-21.0 Gy). In right-sided breast cancer, the average mean heart dose was 3.3 Gy based on 45 regimens in 23 studies. Recent estimates of typical heart doses from left breast cancer radiation therapy vary widely between studies, even for apparently similar regimens. Maneuvers to reduce heart dose in left tangential radiation therapy were successful. Proton radiation therapy delivered the lowest doses. Inclusion of the IMC doubled typical heart dose. Copyright © 2015 Elsevier Inc. All rights reserved.
Ragupathi, Loheetha; Johnson, Drew; Greenspon, Arnold; Frisch, Daniel; Ho, Reginald T; Pavri, Behzad B
2018-04-18
Atrioventricular (AV) block is usually due to infranodal disease and associated with a wide QRS complex; such patients often progress to complete AV block and pacemaker dependency. Uncommonly, infranodal AV block can occur within the His bundle with a narrow QRS complex. The aims of this study were to define clinical/echocardiographic characteristics of patients with AV block within the His bundle and report progression to pacemaker dependency. We retrospectively identified patients with narrow QRS complexes and documented intra-His delay or block at electrophysiology study (group A) or with electrocardiogram-documented Mobitz II AV block/paroxysmal AV block (group B). Clinical, electrophysiological, and echocardiographic variables at presentation and pacemaker parameters at the last follow-up visit were evaluated. Twenty-seven patients (19 women) were identified (mean age 64 ± 13 years; range, 38-85 years). Four patients who had <1 month of follow-up were excluded. There were 12 patients in group A and 11 in group B; 21 of 23 presented with syncope/presyncope. All patients received pacemakers: 8 single chamber and 15 dual chamber. After a median follow-up of 6.4 years, the median percentage of ventricular pacing was 1% (interquartile range 0%-4.66%). One patient developed true pacemaker dependency. Aortic and/or mitral annular calcification was present in 13 of 22 patients with available echocardiograms. Patients who present with syncope and narrow QRS complexes with intra-His delay or Mobitz II paroxysmal AV block with narrow QRS complexes rarely progress to pacemaker dependency and require infrequent pacing. This entity is more common in women, with a higher prevalence of aortic and/or mitral annular calcification. If confirmed by additional studies, single-chamber pacemaker may be sufficient. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Genomes: At the edge of chaos with maximum information capacity
NASA Astrophysics Data System (ADS)
Kong, Sing-Guan; Chen, Hong-Da; Torda, Andrew; Lee, H. C.
2016-12-01
We propose an order index, ϕ, which quantifies the notion of “life at the edge of chaos” when applied to genome sequences. It maps genomes to a number from 0 (random and of infinite length) to 1 (fully ordered) and applies regardless of sequence length and base composition. The 786 complete genomic sequences in GenBank were found to have ϕ values in a very narrow range, 0.037 ± 0.027. We show this implies that genomes are halfway towards being completely random, namely, at the edge of chaos. We argue that this narrow range represents the neighborhood of a fixed-point in the space of sequences, and genomes are driven there by the dynamics of a robust, predominantly neutral evolution process.
Injection-seeded tunable mid-infrared pulses generated by difference frequency mixing
NASA Astrophysics Data System (ADS)
Miyamoto, Yuki; Hara, Hideaki; Masuda, Takahiko; Hiraki, Takahiro; Sasao, Noboru; Uetake, Satoshi
2017-03-01
We report on the generation of nanosecond mid-infrared pulses having frequency tunability, a narrow linewidth, and a high pulse energy. These pulses are obtained by frequency mixing between injection-seeded near-infrared pulses in potassium titanyl arsenate crystals. A continuous-wave external cavity laser diode or a Ti:sapphire ring laser is used as a tunable seeding source for the near-infrared pulses. The typical energy of the generated mid-infrared pulses is in the range of 0.4-1 mJ/pulse. The tuning wavelength ranges from 3142 to 4806 nm. A narrow linewidth of 1.4 GHz and good frequency reproducibility of the mid-infrared pulses are confirmed by observing a rovibrational absorption line of gaseous carbon monoxide at 4587 nm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shirey, R; Wu, H
2016-06-15
Purpose: Treatment planning systems (TPS) may not accurately model superficial dose distributions of range shifted proton pencil beam scanning (PBS) treatments. Numerous patient-specific QA tests performed on superficially treated PBS plans have shown a consistent overestimate of dose by the TPS. This study quantifies variations between TPS planned dose and measured dose as a function of range shifter air gap and treatment depths up to 5 cm. Methods: PBS treatment plans were created in the TPS to uniformly irradiate a volume of solid water. One plan was created for each range shifter position analyzed, and all plans utilized identical dosemore » optimization parameters. Each optimized plan was analyzed in the TPS to determine the planned dose at varying depths. A PBS proton therapy system with a 3.5 cm lucite range shifter delivered the treatment plans, and a parallel plate chamber embedded in RW3 solid water measured dose at shallow depths for each air gap. Differences between measured and planned doses were plotted and analyzed. Results: The data show that the TPS more accurately models superficial dose as the air gap between the range shifter and patient surface decreases. Air gaps less than 10 cm have an average dose difference of only 1.6%, whereas air gaps between 10 and 20 cm differ by 3.0% and gaps greater than 20 cm differ by 4.4%. Conclusion: This study has shown that the TPS is unable to accurately model superficial dose with a large range shifter air gap. Dose differences greater than 3% will likely cause QA failure, as many institutions analyze patient QA with a 3%/3mm gamma analysis. For superficial PBS therapy, range shifter positions should be chosen to keep the air gap less then 10 cm when patient setup and gantry geometry allow.« less
Fan-beam intensity modulated proton therapy.
Hill, Patrick; Westerly, David; Mackie, Thomas
2013-11-01
This paper presents a concept for a proton therapy system capable of delivering intensity modulated proton therapy using a fan beam of protons. This system would allow present and future gantry-based facilities to deliver state-of-the-art proton therapy with the greater normal tissue sparing made possible by intensity modulation techniques. A method for producing a divergent fan beam of protons using a pair of electromagnetic quadrupoles is described and particle transport through the quadrupole doublet is simulated using a commercially available software package. To manipulate the fan beam of protons, a modulation device is developed. This modulator inserts or retracts acrylic leaves of varying thickness from subsections of the fan beam. Each subsection, or beam channel, creates what effectively becomes a beam spot within the fan area. Each channel is able to provide 0-255 mm of range shift for its associated beam spot, or stop the beam and act as an intensity modulator. Results of particle transport simulations through the quadrupole system are incorporated into the MCNPX Monte Carlo transport code along with a model of the range and intensity modulation device. Several design parameters were investigated and optimized, culminating in the ability to create topotherapy treatment plans using distal-edge tracking on both phantom and patient datasets. Beam transport calculations show that a pair of electromagnetic quadrupoles can be used to create a divergent fan beam of 200 MeV protons over a distance of 2.1 m. The quadrupole lengths were 30 and 48 cm, respectively, with transverse field gradients less than 20 T/m, which is within the range of water-cooled magnets for the quadrupole radii used. MCNPX simulations of topotherapy treatment plans suggest that, when using the distal edge tracking delivery method, many delivery angles are more important than insisting on narrow beam channel widths in order to obtain conformal target coverage. Overall, the sharp distal falloff of a proton depth-dose distribution was found to provide sufficient control over the dose distribution to meet objectives, even with coarse lateral resolution and channel widths as large as 2 cm. Treatment plans on both phantom and patient data show that dose conformity suffers when treatments are delivered from less than approximately ten angles. Treatment time for a sample prostate delivery is estimated to be on the order of 10 min, and neutron production is estimated to be comparable to that found for existing collimated systems. Fan beam proton therapy is a method of delivering intensity modulated proton therapy which may be employed as an alternative to magnetic scanning systems. A fan beam of protons can be created by a set of quadrupole magnets and modified by a dual-purpose range and intensity modulator. This can be used to deliver inversely planned treatments, with spot intensities optimized to meet user defined dose objectives. Additionally, the ability of a fan beam delivery system to effectively treat multiple beam spots simultaneously may provide advantages as compared to spot scanning deliveries.
Gwosch, K; Hartmann, B; Jakubek, J; Granja, C; Soukup, P; Jäkel, O; Martišíková, M
2013-06-07
Radiotherapy with narrow scanned carbon ion beams enables a highly accurate treatment of tumours while sparing the surrounding healthy tissue. Changes in the patient's geometry can alter the actual ion range in tissue and result in unfavourable changes in the dose distribution. Consequently, it is desired to verify the actual beam delivery within the patient. Real-time and non-invasive measurement methods are preferable. Currently, the only technically feasible method to monitor the delivered dose distribution within the patient is based on tissue activation measurements by means of positron emission tomography (PET). An alternative monitoring method based on tracking of prompt secondary ions leaving a patient irradiated with carbon ion beams has been previously suggested. It is expected to help in overcoming the limitations of the PET-based technique like physiological washout of the beam induced activity, low signal and to allow for real-time measurements. In this paper, measurements of secondary charged particle tracks around a head-sized homogeneous PMMA phantom irradiated with pencil-like carbon ion beams are presented. The investigated energies and beam widths are within the therapeutically used range. The aim of the study is to deduce properties of the primary beam from the distribution of the secondary charged particles. Experiments were performed at the Heidelberg Ion Beam Therapy Center, Germany. The directions of secondary charged particles emerging from the PMMA phantom were measured using an arrangement of two parallel pixelated silicon detectors (Timepix). The distribution of the registered particle tracks was analysed to deduce its dependence on clinically important beam parameters: beam range, width and position. Distinct dependencies of the secondary particle tracks on the properties of the primary carbon ion beam were observed. In the particular experimental set-up used, beam range differences of 1.3 mm were detectable. In addition, variations in the beam width could be measured with a precision of 0.9 mm. Furthermore, shifts of the lateral beam position could be monitored with a sub-millimetre precision. The presented investigations demonstrate experimentally that the non-invasive measurement and analysis of secondary ion distributions around head-sized homogeneous objects provide information on the actual beam delivery. Beam range, width and position could be monitored with a precision attractive for therapeutic situations.
Performance of commercial platforms for rapid genotyping of polymorphisms affecting warfarin dose.
King, Cristi R; Porche-Sorbet, Rhonda M; Gage, Brian F; Ridker, Paul M; Renaud, Yannick; Phillips, Michael S; Eby, Charles
2008-06-01
Initiation of warfarin therapy is associated with bleeding owing to its narrow therapeutic window and unpredictable therapeutic dose. Pharmacogenetic-based dosing algorithms can improve accuracy of initial warfarin dosing but require rapid genotyping for cytochrome P-450 2C9 (CYP2C9) *2 and *3 single nucleotide polymorphisms (SNPs) and a vitamin K epoxide reductase (VKORC1) SNP. We evaluated 4 commercial systems: INFINITI analyzer (AutoGenomics, Carlsbad, CA), Invader assay (Third Wave Technologies, Madison, WI), Tag-It Mutation Detection assay (Luminex Molecular Diagnostics, formerly Tm Bioscience, Toronto, Canada), and Pyrosequencing (Biotage, Uppsala, Sweden). We genotyped 112 DNA samples and resolved any discrepancies with bidirectional sequencing. The INFINITI analyzer was 100% accurate for all SNPs and required 8 hours. Invader and Tag-It were 100% accurate for CYP2C9 SNPs, 99% accurate for VKORC1 -1639/3673 SNP, and required 3 hours and 8 hours, respectively. Pyrosequencing was 99% accurate for CYP2C9 *2, 100% accurate for CYP2C9 *3, and 100% accurate for VKORC1 and required 4 hours. Current commercial platforms provide accurate and rapid genotypes for pharmacogenetic dosing during initiation of warfarin therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Viel, Francis; Duzenli, Cheryl; British Columbia Cancer Agency, Department of Medical Physics, Vancouver Centre
2014-08-15
Introduction: Radiation detector responses can be affected by dose rate. Due to higher dose per pulse and wider range of mu rates in FFF beams, detector responses should be characterized prior to implementation of QA protocols for FFF beams. During VMAT delivery, the MU rate may also vary dramatically within a treatment fraction. This study looks at the dose per pulse variation throughout a 3D volume for typical VMAT plans and the response characteristics for a variety of detectors, and makes recommendations on the design of QA protocols for FFF VMAT QA. Materials and Methods: Linac log file data andmore » a simplified dose calculation algorithm are used to calculate dose per pulse for a variety of clinical VMAT plans, on a voxel by voxel basis, as a function of time in a cylindrical phantom. Diode and ion chamber array responses are characterized over the relevant range of dose per pulse and dose rate. Results: Dose per pulse ranges from <0.1 mGy/pulse to 1.5 mGy/pulse in a typical VMAT treatment delivery using the 10XFFF beam. Diode detector arrays demonstrate increased sensitivity to dose (+./− 3%) with increasing dose per pulse over this range. Ion chamber arrays demonstrate decreased sensitivity to dose (+/− 1%) with increasing dose rate over this range. Conclusions: QA protocols should be designed taking into consideration inherent changes in detector sensitivity with dose rate. Neglecting to account for changes in detector response with dose per pulse can lead to skewed QA results.« less
Dose rate calculations around 192Ir brachytherapy sources using a Sievert integration model
NASA Astrophysics Data System (ADS)
Karaiskos, P.; Angelopoulos, A.; Baras, P.; Rozaki-Mavrouli, H.; Sandilos, P.; Vlachos, L.; Sakelliou, L.
2000-02-01
The classical Sievert integral method is a valuable tool for dose rate calculations around brachytherapy sources, combining simplicity with reasonable computational times. However, its accuracy in predicting dose rate anisotropy around 192 Ir brachytherapy sources has been repeatedly put into question. In this work, we used a primary and scatter separation technique to improve an existing modification of the Sievert integral (Williamson's isotropic scatter model) that determines dose rate anisotropy around commercially available 192 Ir brachytherapy sources. The proposed Sievert formalism provides increased accuracy while maintaining the simplicity and computational time efficiency of the Sievert integral method. To describe transmission within the materials encountered, the formalism makes use of narrow beam attenuation coefficients which can be directly and easily calculated from the initially emitted 192 Ir spectrum. The other numerical parameters required for its implementation, once calculated with the aid of our home-made Monte Carlo simulation code, can be used for any 192 Ir source design. Calculations of dose rate and anisotropy functions with the proposed Sievert expression, around commonly used 192 Ir high dose rate sources and other 192 Ir elongated source designs, are in good agreement with corresponding accurate Monte Carlo results which have been reported by our group and other authors.
NASA Astrophysics Data System (ADS)
Talamonti, C.; Bucciolini, M.; Marrazzo, L.; Menichelli, D.; Bruzzi, M.; Cirrone, G. A. P.; Cuttone, G.; LoJacono, P.
2008-10-01
Due to the features of the modern radiotherapy techniques, namely intensity modulated radiation therapy and proton therapy, where high spatial dose gradients are often present, detectors to be employed for 2D dose verifications have to satisfy very narrow requirements. In particular they have to show high spatial resolution. In the framework of the European Integrated Project—Methods and Advanced Equipment for Simulation and Treatment in Radio-Oncology (MAESTRO, no. LSHC-CT-2004-503564), a dosimetric detector adequate for 2D pre-treatment dose verifications was developed. It is a modular detector, based on a monolithic silicon-segmented sensor, with an n-type implantation on an epitaxial p-type layer. Each pixel element is 2×2 mm 2 and the distance center-to-center is 3 mm. The sensor is composed of 21×21 pixels. In this paper, we report the dosimetric characterization of the system with a proton beam. The sensor was irradiated with 62 MeV protons for clinical treatments at INFN-Laboratori Nazionali del Sud (LNS) Catania. The studied parameters were repeatability of a same pixel, response linearity versus absorbed dose, and dose rate and dependence on field size. The obtained results are promising since the performances are within the project specifications.
Kuang, Qiao-Ting; Zhao, Jing-Jing; Ye, Chun-Ling; Wang, Jing-Ru; Ye, Kai-He; Zhang, Xiao-Qi; Wang, Ying; Ye, Wen-Cai
2012-01-01
To investigate the nephro-protective effects of total triterpenoids from Psidium guajava leaves (TTPGL) on type 2 diabetic rats. Diabetic rats were induced by intraperitoneal injection of streptozotocin (STZ, 35 mg/kg) and a high-fat diet. Diabetic rats were divided into five groups: diabetic model control, low-dose TTPGL-treated (60 mg/kg, L-TTPGL), medium-dose TTPGL-treated (120 mg/kg, M-TTPGL), high-dose TTPGL-treated (240 mg/kg, H-TTPGL) and rosiglitazone-treated (3 mg/kg, RSG). The rats received daily treatment for six weeks. At the end of the period,the levels of fasting blood glucose (FPG), fasting insulin (FINS), creatinine (Cr) and blood urea nitrogen (BUN) in serum were measured. Kidneys for histopathological evaluation were stained with Hematoxylin and Eosin (HE). Compared with normal control group, the level of FPG was increased, the insulin and insulin sensitivity index were decreased in the model group; The levels of BUN and Cr were increased with histopathological changes related to diabetic nephropathy in the kidney, which were the glomerular endothelium and mesangial cell proliferation, capillary narrowed, the base-membrane incrassation, glomerular swelling, cysts narrowed and tubules edema. Compared with the model group, the levels of FPG were decreased, serum insulin and insulin sensitivity index were increased significantly in M-TTPGL and H-TTPGL groups (P<0.01 or P<0.05); The levels of BUN and Cr were decreased significantly (P<0.01 or P<0.05) and the renal structural damages were improved significantly. TTPGL could decrease the level of blood glucose of diabetic rat effectively, increase the insulin sensitivity index and protect renal lesions in diabetic rats.
Polaron theory of high- Tc superconductors
NASA Astrophysics Data System (ADS)
Alexandrov, A. S.
1989-05-01
It is shown that the ordinary electron-phonon interaction can produce a high Tc as a result of the polaron narrowing of the band, which is not considered by the traditional theory of strong-coupling superconductors based on Migdal-Eliashberg equations, which are violated even in the range of moderate values λ ⪖1. Numerous experimental data are discussed which seem to favour a phonon-mediated attraction, polaron mass enhancement, narrow band and nonadiabatic motion of carriers and charged Bose-like excitations in high Tc metallic oxides.
Lukianova-Hleb, Ekaterina Y; Volkov, Alexey N; Wu, Xiangwei; Lapotko, Dmitri O
2013-02-06
The transient 100-fold enhancement and spectral narrowing to 2 nm of the photothermal conversion by solid gold nanospheres under near-infrared excitation with a short laser pulse is reported. This non-stationary effect was observed for a wide range of optical fluences starting from 10 mJ cm(-2) for single nanospheres, their ensembles and aggregated clusters in water, in vitro and in vivo. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Shirasaka, Takashi; Funama, Yoshinori; Hayashi, Mutsukazu; Awamoto, Shinichi; Kondo, Masatoshi; Nakamura, Yasuhiko; Hatakenaka, Masamitsu; Honda, Hiroshi
2012-01-01
Our purpose in this study was to assess the radiation dose reduction and the actual exposed scan length of over-range areas using a spiral dynamic z-collimator at different beam pitches and detector coverage. Using glass rod dosimeters, we measured the unilateral over-range scan dose between the beginning of the planned scan range and the beginning of the actual exposed scan range. Scanning was performed at detector coverage of 80.0 and 40.0 mm, with and without the spiral dynamic z-collimator. The dose-saving ratio was calculated as the ratio of the unnecessary over-range dose, with and without the spiral dynamic z-collimator. In 80.0 mm detector coverage without the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 108, 120, and 126 mm, corresponding to a beam pitch of 0.60, 0.80, and 0.99, respectively. With the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 48, 66, and 84 mm with a beam pitch of 0.60, 0.80, and 0.99, respectively. The dose-saving ratios with and without the spiral dynamic z-collimator for a beam pitch of 0.60, 0.80, and 0.99 were 35.07, 24.76, and 13.51%, respectively. With 40.0 mm detector coverage, the dose-saving ratios with and without the spiral dynamic z-collimator had the highest value of 27.23% with a low beam pitch of 0.60. The spiral dynamic z-collimator is important for a reduction in the unnecessary over-range dose and makes it possible to reduce the unnecessary dose by means of a lower beam pitch.
Sun, Junjie; Wang, Zefeng; Wang, Meng; Zhou, Zhiyue; Tang, Ni; Chen, Jinbao; Gu, Xijia
2017-11-10
A watt-level tunable 1.5 μm narrow linewidth fiber ring laser using a temperature tuning π-phase-shifted fiber Bragg grating (π-PSFBG) is demonstrated here, to the best of our knowledge, for the first time. The π-PSFBG is employed as both a narrow band filter and a wavelength tuning component, and its central wavelength is thermally tuned by a thermo-electric cooler. The maximum laser power is about 1.1 W with a linewidth of ∼318 MHz (∼2.57 pm) and a power fluctuation of less than 3%. The wavelength tuning range of the laser is about 1.29 nm with a sensitivity of ∼14.33 pm/°C, and the wavelength fluctuation is about 0.2 pm. This work provides important reference for tunable fiber lasers with both high power and narrow linewidth.
Fear, Worry, and Ritualistic Behaviour in Childhood: Developmental Trends and Interrelations
ERIC Educational Resources Information Center
Laing, Sarah V.; Fernyhough, Charles; Turner, Michelle; Freeston, Mark H.
2009-01-01
Previous studies of childhood fear, worry, and ritualistic behaviour have been limited by restricted age ranges, narrow ranges of anxiety phenomena, non-comparable methodologies, and assessment of typical behaviour within a pathological context. Content and intensity of fear, worry, and ritualistic behaviour, and associations among these…
Endosulfan Toxicity to Anabas testudineus and Histopathological Changes on Vital Organs
NASA Astrophysics Data System (ADS)
Nordin, I. L.; Ibrahim, N.; Ahmad, S. A.; Hamidin, N. l.; Dahalan, F. A.; Abd. Shukor, M. Y.
2018-03-01
The toxicity of endosulfan, an organochlorine type insecticide to a commonly consumed freshwater fish species, A. testudineus (40.68±9.03 g; 13.49±0.99 cm), was investigated under static conditions. The nominal endosulfan concentrations ranging from 10 to 80 μg/L subjected to the fish population results in 96-hour median lethal concentration, LC50, of 35.2±3.99 μg/L. The toxicity is a function of both endosulfan concentration and exposure time (p>0.05). Histopathological analysis on vital organs exposed to sublethal concentrations indicates that structural changes started at sublethal dose and the effects aggravated with increasing endosulfan concentration. Gill was found to experience aneurism, hyperplasia in lamellar and autolysis of mast cell. Pyknotic nuclei and necrosis were observed in liver cell, while the lumen of renal tubule was found to narrow and haemorrhage was observed in cytoplasm cell. High LC50 compared to other fishes indicates that A. testudineus has high tolerant to endosulfan, however, endosulfan slowly alters the fish biochemistry and is potentially transferable to human
Kanematsu, Nobuyuki; Komori, Masataka; Yonai, Shunsuke; Ishizaki, Azusa
2009-04-07
The pencil-beam algorithm is valid only when elementary Gaussian beams are small enough compared to the lateral heterogeneity of a medium, which is not always true in actual radiotherapy with protons and ions. This work addresses a solution for the problem. We found approximate self-similarity of Gaussian distributions, with which Gaussian beams can split into narrower and deflecting daughter beams when their sizes have overreached lateral heterogeneity in the beam-transport calculation. The effectiveness was assessed in a carbon-ion beam experiment in the presence of steep range compensation, where the splitting calculation reproduced a detour effect amounting to about 10% in dose or as large as the lateral particle disequilibrium effect. The efficiency was analyzed in calculations for carbon-ion and proton radiations with a heterogeneous phantom model, where the beam splitting increased computing times by factors of 4.7 and 3.2. The present method generally improves the accuracy of the pencil-beam algorithm without severe inefficiency. It will therefore be useful for treatment planning and potentially other demanding applications.
Boda, Zoltán
2016-03-20
Only vitamin K antagonists could be applied as oral anticoagulants over the past six decades. Coumarols have narrow therapeutic range, and unpredictable anticoagulant effects are resulted by multiple drug interactions. Therefore, regular routine monitoring of the international normalized ratio is necessary. There are two groups of factor-specific anticoagulants: molecules with anti-FIIa (dabigatran) and anti-FXa (rivaroxaban, apixaban and edoxaban) effect. Author summarizes the most important clinical features of the new oral anticoagulants, their indications and the possibilities of laboratory controls. Bleedings are the most important side effects of anticoagulants. This review summarizes the current published evidences for new oral anticoagulants reversal (non-specific and specific) agents, especially in cases with severe acute bleedings or urgent surgery procedures. It reports on how to use inhibitors, the recommended doses and the most important clinical results. The review focuses on idarucizumab - already approved by the U.S. Food and Drug Administration and the European Medicines Agency - which has a key role as the first specific inhibitor of dabigatran.
Lukášová, Ivana; Muselík, Jan; Franc, Aleš; Goněc, Roman; Mika, Filip; Vetchý, David
2017-11-15
Warfarin is intensively discussed drug with narrow therapeutic range. There have been cases of bleeding attributed to varying content or altered quality of the active substance. Factor analysis is useful for finding suitable technological parameters leading to high content uniformity of tablets containing low amount of active substance. The composition of tabletting blend and technological procedure were set with respect to factor analysis of previously published results. The correctness of set parameters was checked by manufacturing and evaluation of tablets containing 1-10mg of warfarin sodium. The robustness of suggested technology was checked by using "worst case scenario" and statistical evaluation of European Pharmacopoeia (EP) content uniformity limits with respect to Bergum division and process capability index (Cpk). To evaluate the quality of active substance and tablets, dissolution method was developed (water; EP apparatus II; 25rpm), allowing for statistical comparison of dissolution profiles. Obtained results prove the suitability of factor analysis to optimize the composition with respect to batches manufactured previously and thus the use of metaanalysis under industrial conditions is feasible. Copyright © 2017 Elsevier B.V. All rights reserved.
Zink, F E; McCollough, C H
1994-08-01
The unique geometry of electron-beam CT (EBCT) scanners produces radiation dose profiles with widths which can be considerably different from the corresponding nominal scan width. Additionally, EBCT scanners produce both complex (multiple-slice) and narrow (3 mm) radiation profiles. This work describes the measurement of the axial dose distribution from EBCT within a scattering phantom using film dosimetry methods, which offer increased convenience and spatial resolution compared to thermoluminescent dosimetry (TLD) techniques. Therapy localization film was cut into 8 x 220 mm strips and placed within specially constructed light-tight holders for placement within the cavities of a CT Dose Index (CTDI) phantom. The film was calibrated using a conventional overhead x-ray tube with spectral characteristics matched to the EBCT scanner (130 kVp, 10 mm A1 HVL). The films were digitized at five samples per mm and calibrated dose profiles plotted as a function of z-axis position. Errors due to angle-of-incidence and beam hardening were estimated to be less than 5% and 10%, respectively. The integral exposure under film dose profiles agreed with ion-chamber measurements to within 15%. Exposures measured along the radiation profile differed from TLD measurements by an average of 5%. The film technique provided acceptable accuracy and convenience in comparison to conventional TLD methods, and allowed high spatial-resolution measurement of EBCT radiation dose profiles.
Cameron, Danielle B; Melvin, Patrice; Graham, Dionne A; Glass, Charity C; Serres, Stephanie K; Kronman, Matthew P; Saito, Jacqueline M; Rangel, Shawn J
2018-07-01
The aim of this study was to compare the effectiveness of extended versus narrow spectrum antibiotics in preventing surgical site infections (SSIs) and hospital revisits in children with uncomplicated appendicitis. There is a paucity of high-quality evidence in the pediatric literature comparing the effectiveness of extended versus narrow-spectrum antibiotics in the prevention of SSIs associated with uncomplicated appendicitis. Clinical data from the ACS NSQIP-Pediatric Appendectomy Pilot Project were merged with antibiotic utilization data from the Pediatric Health Information System database for patients undergoing appendectomy for uncomplicated appendicitis at 17 hospitals from January 1, 2013 to June 30, 2015. Patients who received piperacillin/tazobactam (extended spectrum) were compared with those who received either cefoxitin or ceftriaxone with metronidazole (narrow spectrum) after propensity matching on demographic and severity characteristics. Study outcomes were 30-day SSI and hospital revisit rates. Of the 1389 patients included, 39.1% received piperacillin/tazobactam (range by hospital: 0% to 100%), and the remainder received narrow-spectrum agents. No differences in demographics or severity characteristics were found between groups following matching. In the matched analysis, the rates of SSI were similar between groups [extended spectrum: 2.4% vs narrow spectrum 1.8% (odds ratio, OR: 1.05, 95% confidence interval, 95% CI 0.34-3.26)], as was the rate of revisits [extended spectrum: 7.9% vs narrow spectrum 5.1% (OR: 1.46, 95% CI 0.75-2.87)]. Use of extended-spectrum antibiotics was not associated with lower rates of SSI or hospital revisits when compared with narrow-spectrum antibiotics in children with uncomplicated appendicitis. Our results challenge the routine use of extended-spectrum antibiotics observed at many hospitals, particularly given the increasing incidence of antibiotic-resistant organisms.
Current status and recent research achievements in ferritic/martensitic steels
NASA Astrophysics Data System (ADS)
Tavassoli, A.-A. F.; Diegele, E.; Lindau, R.; Luzginova, N.; Tanigawa, H.
2014-12-01
When the austenitic stainless steel 316L(N) was selected for ITER, it was well known that it would not be suitable for DEMO and fusion reactors due to its irradiation swelling at high doses. A parallel programme to ITER collaboration already had been put in place, under an IEA fusion materials implementing agreement for the development of a low activation ferritic/martensitic steel, known for their excellent high dose irradiation swelling resistance. After extensive screening tests on different compositions of Fe-Cr alloys, the chromium range was narrowed to 7-9% and the first RAFM was industrially produced in Japan (F82H: Fe-8%Cr-2%W-TaV). All IEA partners tested this steel and contributed to its maturity. In parallel several other RAFM steels were produced in other countries. From those experiences and also for improving neutron efficiency and corrosion resistance, European Union opted for a higher chromium lower tungsten grade, Fe-9%Cr-1%W-TaV steel (Eurofer), and in 1997 ordered the first industrial heats. Other industrial heats have been produced since and characterised in different states, including irradiated up to 80 dpa. China, India, Russia, Korea and US have also produced their grades of RAFM steels, contributing to overall maturity of these steels. This paper reviews the work done on RAFM steels by the fusion materials community over the past 30 years, in particular on the Eurofer steel and its design code qualification for RCC-MRx.
Nonlinear dynamic range transformation in visual communication channels.
Alter-Gartenberg, R
1996-01-01
The article evaluates nonlinear dynamic range transformation in the context of the end-to-end continuous-input/discrete processing/continuous-display imaging process. Dynamic range transformation is required when we have the following: (i) the wide dynamic range encountered in nature is compressed into the relatively narrow dynamic range of the display, particularly for spatially varying irradiance (e.g., shadow); (ii) coarse quantization is expanded to the wider dynamic range of the display; and (iii) nonlinear tone scale transformation compensates for the correction in the camera amplifier.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, Carolyn W., E-mail: carolyn.taylor@ctsu.ox.ac.uk; Wang, Zhe; Macaulay, Elizabeth
Purpose: Breast cancer radiation therapy cures many women, but where the heart is exposed, it can cause heart disease. We report a systematic review of heart doses from breast cancer radiation therapy that were published during 2003 to 2013. Methods and Materials: Eligible studies were those reporting whole-heart dose (ie, dose averaged over the whole heart). Analyses considered the arithmetic mean of the whole-heart doses for the CT plans for each regimen in each study. We termed this “mean heart dose.” Results: In left-sided breast cancer, mean heart dose averaged over all 398 regimens reported in 149 studies from 28more » countries was 5.4 Gy (range, <0.1-28.6 Gy). In regimens that did not include the internal mammary chain (IMC), average mean heart dose was 4.2 Gy and varied with the target tissues irradiated. The lowest average mean heart doses were from tangential radiation therapy with either breathing control (1.3 Gy; range, 0.4-2.5 Gy) or treatment in the lateral decubitus position (1.2 Gy; range, 0.8-1.7 Gy), or from proton radiation therapy (0.5 Gy; range, 0.1-0.8 Gy). For intensity modulated radiation therapy mean heart dose was 5.6 Gy (range, <0.1-23.0 Gy). Where the IMC was irradiated, average mean heart dose was around 8 Gy and varied little according to which other targets were irradiated. Proton radiation therapy delivered the lowest average mean heart dose (2.6 Gy, range, 1.0-6.0 Gy), and tangential radiation therapy with a separate IMC field the highest (9.2 Gy, range, 1.9-21.0 Gy). In right-sided breast cancer, the average mean heart dose was 3.3 Gy based on 45 regimens in 23 studies. Conclusions: Recent estimates of typical heart doses from left breast cancer radiation therapy vary widely between studies, even for apparently similar regimens. Maneuvers to reduce heart dose in left tangential radiation therapy were successful. Proton radiation therapy delivered the lowest doses. Inclusion of the IMC doubled typical heart dose.« less
Dose rate mapping of VMAT treatments
NASA Astrophysics Data System (ADS)
Podesta, Mark; Antoniu Popescu, I.; Verhaegen, Frank
2016-06-01
Human tissues exhibit a varying response to radiation dose depending on the dose rate and fractionation scheme used. Dose rate effects have been reported for different radiations, and tissue types. The literature indicates that there is not a significant difference in response for low-LET radiation when using dose rates between 1 Gy min-1 and 12 Gy min-1 but lower dose rates have an observable sparing effect on tissues and a differential effect between tissues. In intensity-modulated radiotherapy such as volumetric modulated arc therapy (VMAT) the dose can be delivered with a wide range of dose rates. In this work we developed a method based on time-resolved Monte Carlo simulations to quantify the dose rate frequency distribution for clinical VMAT treatments for three cancer sites, head and neck, lung, and pelvis within both planning target volumes (PTV) and normal tissues. The results show a wide range of dose rates are used to deliver dose in VMAT and up to 75% of the PTV can have its dose delivered with dose rates <1 Gy min-1. Pelvic plans on average have a lower mean dose rate within the PTV than lung or head and neck plans but a comparable mean dose rate within the organs at risk. Two VMAT plans that fulfil the same dose objectives and constraints may be delivered with different dose rate distributions, particularly when comparing single arcs to multiple arc plans. It is concluded that for dynamic plans, the dose rate range used varies to a larger degree than previously assumed. The effect of the dose rate range in VMAT on clinical outcome is unknown.
Rees, Frances; Doherty, Sally; Hui, Michelle; Maciewicz, Rose; Muir, Kenneth; Zhang, Weiya; Doherty, Michael
2012-04-01
To determine the distribution of clinically palpable hand interphalangeal (IP) nodes at each finger and thumb joint in a population with nodes, the influence of left or right hand dominance and sex on the development of nodes, and the association between nodes and underlying radiographic features of osteoarthritis (OA). We performed a cross-sectional analysis of participants in the Genetics of Osteoarthritis and Lifestyle (GOAL) study who had ≥1 Heberden's nodes or Bouchard's nodes on clinical examination. Frequencies (%) of nodes were described for each IP joint in the hand. Associations between nodes and underlying radiographic OA were shown with odds ratios (ORs) and 95% confidence intervals. A logistic regression model was used to adjust for the following confounding factors: age, sex, body mass index, left or right hand dominance, hand trauma, occupation with heavy manual activity, and participation in sports. Of the 3,170 GOAL participants, 1,939 had ≥1 nodes (mean age 68 years, 54% women). The distal IP joints of the index finger were the most frequently affected, followed by the thumb IP joint. Nodes were more common in dominant hands and women. There was a significant association between nodes and underlying radiographic OA (OR range 2.26-21.23). This association was stronger for joint space narrowing than for osteophytes. A dose-response relationship was found between clinical severity of Heberden's nodes and underlying radiographic change. Our study supports the positive association between nodes and radiographic OA, especially narrowing, and the influence of sex and left or right hand dominance on development of nodes. In this age group, presence of nodes may be taken as an indication of underlying small joint OA. Copyright © 2012 by the American College of Rheumatology.
Shirey, Robert J; Wu, Hsinshun Terry
2018-01-01
This study quantifies the dosimetric accuracy of a commercial treatment planning system as functions of treatment depth, air gap, and range shifter thickness for superficial pencil beam scanning proton therapy treatments. The RayStation 6 pencil beam and Monte Carlo dose engines were each used to calculate the dose distributions for a single treatment plan with varying range shifter air gaps. Central axis dose values extracted from each of the calculated plans were compared to dose values measured with a calibrated PTW Markus chamber at various depths in RW3 solid water. Dose was measured at 12 depths, ranging from the surface to 5 cm, for each of the 18 different air gaps, which ranged from 0.5 to 28 cm. TPS dosimetric accuracy, defined as the ratio of calculated dose relative to the measured dose, was plotted as functions of depth and air gap for the pencil beam and Monte Carlo dose algorithms. The accuracy of the TPS pencil beam dose algorithm was found to be clinically unacceptable at depths shallower than 3 cm with air gaps wider than 10 cm, and increased range shifter thickness only added to the dosimetric inaccuracy of the pencil beam algorithm. Each configuration calculated with Monte Carlo was determined to be clinically acceptable. Further comparisons of the Monte Carlo dose algorithm to the measured spread-out Bragg Peaks of multiple fields used during machine commissioning verified the dosimetric accuracy of Monte Carlo in a variety of beam energies and field sizes. Discrepancies between measured and TPS calculated dose values can mainly be attributed to the ability (or lack thereof) of the TPS pencil beam dose algorithm to properly model secondary proton scatter generated in the range shifter. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Priyadarshika, R C U; Crosbie, J C; Kumar, B; Rogers, P A W
2011-01-01
Objectives Microbeam radiotherapy (MRT) with wafers of microscopically narrow, synchrotron generated X-rays is being used for pre-clinical cancer trials in animal models. It has been shown that high dose MRT can be effective at destroying tumours in animal models, while causing unexpectedly little damage to normal tissue. The aim of this study was to use a dermatopathological scoring system to quantify and compare the acute biological response of normal mouse skin with microplanar and broad-beam (BB) radiation as a basis for biological dosimetry. Method The skin flaps of three groups of mice were irradiated with high entrance doses (200 Gy, 400 Gy and 800 Gy) of MRT and BB and low dose BB (11 Gy, 22 Gy and 44 Gy). The mice were culled at different time-points post-irradiation. Skin sections were evaluated histologically using the following parameters: epidermal cell death, nuclear enlargement, spongiosis, hair follicle damage and dermal inflammation. The fields of irradiation were identified by γH2AX-positive immunostaining. Results The acute radiation damage in skin from high dose MRT was significantly lower than from high dose BB and, importantly, similar to low dose BB. Conclusion The integrated MRT dose was more relevant than the peak or valley dose when comparing with BB fields. In MRT-treated skin, the apoptotic cells of epidermis and hair follicles were not confined to the microbeam paths. PMID:21849367
Limoges, D; Dieterich, H A; Yeh, C-M; Vaidyanathan, S; Howard, D; Dole, W P
2008-05-01
To evaluate the dose-proportionality of the pharmacokinetics of aliskiren, the first in a new class of orally active direct renin inhibitors approved for the treatment of hypertension. This was an open-label, single-center, single-dose, randomized, 4-period crossover study. Following a 21-day screening period, 32 healthy male or female subjects (ages 18 - 45 years) were randomized to 1 of 4 aliskiren dosing sequence groups (8 subjects per group): 75, 150, 300 and 600 mg. Blood samples were obtained for determination of plasma aliskiren concentrations (HPLC/MS/MS) for 96 h post dose. Log-transformed pharmacokinetic parameters AUC and C(max) were analyzed to determine dose-proportionality using the power model, parameter = A*(Dose)(beta), where A = intercept and beta = dose-proportionality coefficient. The predefined dose-proportionality criteria over the dose range 75 â 600 mg were 90% confidence intervals (CI) for beta contained within the range 0.89 - 1.11. AUC and Cmax values increased with increasing doses of aliskiren. Both AUC and C(max) were associated with high variability (coefficient of variation 55 - 64% for AUC and 59 - 117% for C(max)). The estimated proportionality coefficients (beta) for AUC(0-infiniti), AUC(0-t) and C(max) were 1.18 (90% CI 1.10, 1.25), 1.29 (90% CI 1.22, 1.36) and 1.42 (90% CI 1.31, 1.52), respectively. Dose-proportionality was, therefore, not demonstrated across the entire 8-fold dose range. For the clinical dose range of 150 â 300 mg, increases of 2.3- and 2.6-fold were observed for AUC and C(max), respectively. All doses of aliskiren were well tolerated. Exposure to aliskiren was greater than proportional over the dose range of 75 - 600 mg. Over the therapeutic dose range of 150 â 300 mg approved for the treatment of hypertension, AUC and Cmax increased by 2.3- and 2.6-fold, respectively. The pharmacokinetics of aliskiren show relatively high intersubject variability.
NASA Astrophysics Data System (ADS)
Ullrich, B.; Schroeder, R.
2001-08-01
Thin (10 µm) film CdS on Pyrex® formed by spray pyrolysis is excited below the gap at 804 nm with 200 fs laser pulses at room temperature. Excitation intensities up to 250 GW cm-2 evoke green bandgap emission due to two-photon transitions. This two-photon photoluminescence does not show a red emission contribution in contrast to the single-photon excited emission, which is dominated by broad emission in the red spectral range. It is demonstrated that two-photon excitation causes photo-induced bandgap narrowing due to Debye screening. At 250 GW cm-2 bandgap narrowing of 47 meV is observed, which corresponds to an excited electron density of 1.6×1018 cm-3.
Derivative Analysis of AVIRIS Data for Crop Stress Detection
NASA Technical Reports Server (NTRS)
Estep, Lee; Carter, Gregory A.; Berglund, Judith
2003-01-01
Low-altitude Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) hyperspectral imagery of a cornfield in Nebraska was used to determine whether derivative analysis methods provided enhanced plant stress detection compared with narrow-band ratios. The field was divided into 20 plots representing 4 replicates each of 5 nitrogen (N) fertilization treatments that ranged from 0 to 200 kg N/ha in 50 kg/ha increments. The imagery yielded a 3 m ground pixel size for 224 spectral bands. Derivative analysis provided no advantage in stress detection compared with the performance of narrow-band indices derived from the literature. This result was attributed to a high leaf area index at the time of overflight (LAI approx. equal to 5 to 6t) and the high signal-to-noise character of the narrow AVIRIS bands.
Bordin, Dimorvan; Bergamo, Edmara T P; Fardin, Vinicius P; Coelho, Paulo G; Bonfante, Estevam A
2017-07-01
To assess the probability of survival (reliability) and failure modes of narrow implants with different diameters. For fatigue testing, 42 implants with the same macrogeometry and internal conical connection were divided, according to diameter, as follows: narrow (Ø3.3×10mm) and extra-narrow (Ø2.9×10mm) (21 per group). Identical abutments were torqued to the implants and standardized maxillary incisor crowns were cemented and subjected to step-stress accelerated life testing (SSALT) in water. The use-level probability Weibull curves, and reliability for a mission of 50,000 and 100,000 cycles at 50N, 100, 150 and 180N were calculated. For the finite element analysis (FEA), two virtual models, simulating the samples tested in fatigue, were constructed. Loading at 50N and 100N were applied 30° off-axis at the crown. The von-Mises stress was calculated for implant and abutment. The beta (β) values were: 0.67 for narrow and 1.32 for extra-narrow implants, indicating that failure rates did not increase with fatigue in the former, but more likely were associated with damage accumulation and wear-out failures in the latter. Both groups showed high reliability (up to 97.5%) at 50 and 100N. A decreased reliability was observed for both groups at 150 and 180N (ranging from 0 to 82.3%), but no significant difference was observed between groups. Failure predominantly involved abutment fracture for both groups. FEA at 50N-load, Ø3.3mm showed higher von-Mises stress for abutment (7.75%) and implant (2%) when compared to the Ø2.9mm. There was no significant difference between narrow and extra-narrow implants regarding probability of survival. The failure mode was similar for both groups, restricted to abutment fracture. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lee, Ji-Hyun; Kim, Sang-Soo; Kim, Geun-Tae
2013-01-01
Although a series of trials support systemic lupus erythematosus (SLE) is associated with increased atherosclerosis and cardiovascular events, the link between microvascular structural change and the disease activity of SLE is not defined. We measured retinal microvasculature change by fundus photography with fluorescein angiography (FAG) and investigated the association between retinal vasculature and clinical parameters of SLE. Fifty SLE patients and fifty healthy controls were included. Morphometric and quantitative features of the capillary image including retinal vascular sign and vessel diameters were measured with fundus photography and FAG. Information concerning SLE duration, cumulative dose of steroids and/or immunosuppressive drug intake was recorded, and autoantibodies were checked. SLE activity was assessed by SLE disease activity index (SLEDAI). The mean central retinal arteriolar equivalent (CRAE) was 89.7±14.5 μm in SLE patients, showing narrower arteriole than that of controls (102.2±11.3 μm). The mean central retinal venular equivalents (CRVE) was 127.7±14.8 μm in SLE patients, also, narrower than that of controls (144.1±14.2 μm), but both reached no statistical significance (p=0.154, p=0.609, respectively). Retinopathy was found in 26% of SLE patients. SLE patients with retinopathy were older than those without it, but reached no statistical significance. Disease duration, antidsDNA, and complement levels had no effect on the presence of retinopathy. SLE patients with retinopathy had a tendency to have higher cumulative steroid doses, hsCRP and IgG aCL levels than those without retinopathy. With multiple regression analysis, hsCRP and IgG aCL were identified as contributing factors to the decreased CRAE, whereas no contributing factor was found to CRVE. Retinopathy and retinal arteriolar narrowing were more common in SLE patients, and retinal arteriolar diameter had significant correlation with hsCRP and IgG aCL levels. Retinal imaging is a comparative method for the assessment of microvascular findings of SLE patients.
2011-01-01
Background Many countries, such as Niger, are considering changing their vaccine vial size presentation and may want to evaluate the subsequent impact on their supply chains, the series of steps required to get vaccines from their manufacturers to patients. The measles vaccine is particularly important in Niger, a country prone to measles outbreaks. Methods We developed a detailed discrete event simulation model of the vaccine supply chain representing every vaccine, storage location, refrigerator, freezer, and transport device (e.g., cold trucks, 4 × 4 trucks, and vaccine carriers) in the Niger Expanded Programme on Immunization (EPI). Experiments simulated the impact of replacing the 10-dose measles vial size with 5-dose, 2-dose and 1-dose vial sizes. Results Switching from the 10-dose to the 5-dose, 2-dose and 1-dose vial sizes decreased the average availability of EPI vaccines for arriving patients from 83% to 82%, 81% and 78%, respectively for a 100% target population size. The switches also changed transport vehicle's utilization from a mean of 58% (range: 4-164%) to means of 59% (range: 4-164%), 62% (range: 4-175%), and 67% (range: 5-192%), respectively, between the regional and district stores, and from a mean of 160% (range: 83-300%) to means of 161% (range: 82-322%), 175% (range: 78-344%), and 198% (range: 88-402%), respectively, between the district to integrated health centres (IHC). The switch also changed district level storage utilization from a mean of 65% to means of 64%, 66% and 68% (range for all scenarios: 3-100%). Finally, accounting for vaccine administration, wastage, and disposal, replacing the 10-dose vial with the 5 or 1-dose vials would increase the cost per immunized patient from $0.47US to $0.71US and $1.26US, respectively. Conclusions The switch from the 10-dose measles vaccines to smaller vial sizes could overwhelm the capacities of many storage facilities and transport vehicles as well as increase the cost per vaccinated child. PMID:21635774
Pardo, Beatriz; Paz-Ares, Luis; Tabernero, Josep; Ciruelos, Eva; García, Margarita; Salazar, Ramón; López, Ana; Blanco, María; Nieto, Antonio; Jimeno, José; Izquierdo, Miguel Angel; Trigo, José Manuel
2008-02-15
A dose-escalation, phase I study evaluated the safety, pharmacokinetics, and efficacy of a weekly 1-h regimen of kahalalide F, a cyclic depsipeptide isolated from the marine mollusk Elysia rufescens, in adult patients with advanced solid tumors and no standard treatment available. Patients received an i.v. 1-h infusion of kahalalide F once weekly until disease progression or unacceptable toxicity. The starting kahalalide F dose was 266 microg/m(2), and dose escalation proceeded based on the worst toxicity found in the previous cohort. Thirty-eight patients were enrolled at three Spanish institutions and received once-weekly kahalalide F 1-h infusions at doses between 266 and 1,200 microg/m(2). Dose-limiting toxicities consisted of transient grade 3/4 increases in transaminase blood levels. The maximum tolerated dose for this kahalalide F schedule was 800 microg/m(2), and the recommended dose for phase II studies was 650 microg/m(2). No accumulated toxicity was found. One patient with malignant melanoma had unconfirmed partial response, one patient with metastatic lung adenocarcinoma had minor response, and six patients with different types of metastatic solid tumors had stable disease for 2.8 to 12.7 months. The noncompartmental pharmacokinetics of this kahalalide F schedule was linear and showed a narrow distribution and short body residence. The transaminitis associated with kahalalide F was dose dependent. The maximum tolerated dose was 800 microg/m(2). Dose-limiting toxicities with weekly kahalalide F 1-h i.v. infusions were transient grade 3/4 increases in blood transaminase levels, and 650 microg/m(2) was declared the recommended dose for phase II studies. This schedule showed a favorable safety profile and hints of antitumor activity.
1992-04-16
the two major ranges is the narrow valley of the ...although lower, is also prominent and rises south of the Northern Plains to form the Aravalli Range in the west and the jungle- covered Chota Nagpur... The global components of the United States’ national security are defined by its national interests. These are delineated in the
Re-Os Isotope Systematics in Lunar Soils and Breccias
NASA Technical Reports Server (NTRS)
Chen, J. H.; Papanastassiou, D. A; Wasserburg, G. J.
2002-01-01
Lunar soil and breccia samples show a narrow range in 187Os/188Os, in the range for H-chondrites and unfractionated irons. All samples show enrichments in 187Re/188Os, possibly reflecting loss of Os, associated with the terminal lunar cataclysm. Additional information is contained in the original extended abstract.
RL10 ignition limits test for Shuttle Centaur
NASA Technical Reports Server (NTRS)
1987-01-01
During routine development testing of the RL10A-3-3B engine a potential no-ignition condition was encountered when operating at certain propellant inlet conditions within the Shuttle Centaur G operating region. The conditions, the resulting investigative program, and methods to correct the potential problem are discussed. The Shuttle Centaur program was cancelled prior to completion of this effort. Although the RL10 engine in the Atlas Centaur vehicle is required by specification to operate over a wide range of propellant inlet conditions. The vehicle actually operates over a narrow range of conditions. This factor, combined with configuration differences between Atlas Centaur (or Titan Centaur) and the Shuttle Centaur RL10 engines, indicates the ignition problem does not exist for these vehicles. As a precautionary measure the vehicle manufacturer was requested to coordinate with Pratt and Whitney any anticipated changes in propellant inlet conditions from the current narrow range. An engineering change will be proposed for future RL10 deliveries to provide more consistent propellant flow to the igniter. This will permit operation of the engine throughout the wide range specification inlet conditions if desired.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucconi, G; Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA; Bentefour, E
Purpose: The clinical commissioning of a workflow for pre-treatment range verification/adjustment for the head treatment of pediatric medulloblastoma patients, including dose monitoring during treatment. Methods: An array of Si-diodes (DIODES Incorporated) is placed on the patient skin on the opposite side to the beam entrance. A “scout” SOBP beam, with a longer beam range to cover the diodes in its plateau, is delivered; the measured signal is analyzed and the extracted water equivalent path lengths (WEPL) are compared to the expected values, revealing if a range correction is needed. Diodes stay in place during treatment to measure dose. The workflowmore » was tested in solid water and head phantoms and validated against independent WEPL measurements. Both measured WEPL and skin doses were compared to computed values from the TPS (XiO); a Markus chamber was used for reference dose measurements. Results: The WEPL accuracy of the method was verified by comparing it with the dose extinction method. It resulted, for both solid water and head phantom, in the sub-millimeter range, with a deviation less than 1% to the value extracted from the TPS. The accuracy of dose measurements in the fall-off part of the dose profile was validated against the Markus chamber. The entire range verification workflow was successfully tested for the mock-treatment of head phantom with the standard delivery of 90 cGy per field per fraction. The WEPL measurement revealed no need for range correction. The dose measurements agreed to better than 4% with the prescription dose. The robustness of the method and workflow, including detector array, hardware set and software functions, was successfully stress-tested with multiple repetitions. Conclusion: The performance of the in-vivo range verification system and related workflow meet the clinical requirements in terms of the needed WEPL accuracy for pretreatment range verification with acceptable dose to the patient.« less
Development of a flexible γ-ray detector using a liquid scintillation light guide (LSLG).
Nomura, Kiyoshi; Yunoki, Akira; Hara, Masayuki; Morito, Yuko; Fujishima, Akira
2018-04-10
A flexible γ detector using a liquid scintillation light guide (LSLG) was developed. The analyzed pulse height (PHA) spectrum depended on the diameter, length and scintillator concentration of the LSLG, and the distance of a γ ray irradiation point from the head of photomultiplier tube (PMT). From the analysis of PHA spectrum, it was found that the count ratio of two divided channel regions linearly decreases as the distance from the PMT head increases. It was further found that the radiation dose rate can be estimated by setting the flexible LSLG tube to a circular shape since the count rate is proportional to the dose rate measured by a conventional NaI (Tl) scintillation detector. Therefore, a flexible and long LSLG detector using a single PMT is useful for determination of the dose rate and has a potential to detect local contaminations in a certain narrow space. Copyright © 2018. Published by Elsevier Ltd.
Overshoot and Non-Overshoot Pathways to 1.5oC and Above: The Temperature Tunnel
NASA Astrophysics Data System (ADS)
Feijoo, F.; Edmonds, J.; Wise, M. A.; Mignone, B.; Kheshgi, H. S.
2017-12-01
We create 3000 temperature pathways that lead to a wide range of outcomes in 2100 from below 1.5oC to over 3oC. We use the Global Change Assessment Model (GCAM), which includes the HECTOR physical Earth system model, to generate emission, climate forcing and global temperature trajectories driven by a wide range of assumed carbon price trajectories. While no probability is estimated for the generated trajectories, we report the central estimate of temperature response to emissions from HECTOR. We find that despite the wide range of generated carbon emission trajectories, temperature pathways were constrained to a narrow range until shortly before mid-century. This "temperature tunnel" was the result of two phenomena: first, a narrow range of radiative forcing for 10-15 years created by the concurrent reduction of carbon and aerosol emissions; and second, the thermal lag of the climate response to radiative forcing change of roughly 10-15 years. Scenarios consistent with 1.5oC showed higher short-term temperatures than scenarios consistent with higher temperature outcomes. No scenarios were found that peak below approximately 1.9oC.
SU-E-J-232: Feasibility of MRI-Based Preplan On Low Dose Rate Prostate Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Y; Tward, J; Rassiah-Szegedi, P
Purpose: To investigate the feasibility of using MRI-based preplan for low dose rate prostate brachytherapy. Methods: 12 patients who received transrectal ultrasound (TRUS) guided prostate brachytherapy with Pd-103 were retrospectively studied. Our care-standard of the TRUS-based preplan served as the control. One or more prostate T2-weighted wide and/or narrow-field of view MRIs obtained within the 3 months prior to the implant were imported into the MIM Symphony software v6.3 (MIM Software Inc., Cleveland, OH) for each patient. In total, 37 MRI preplans (10 different image sequences with average thickness of 4.8mm) were generated. The contoured prostate volume and the seedmore » counts required to achieve adequate dosimetric coverage from TRUS and MRI preplans were compared for each patient. The effects of different MRI sequences and image thicknesses were also investigated statistically using Student’s t-test. Lastly, the nomogram from the MRI preplan and TRUS preplan from our historical treatment data were compared. Results: The average prostate volume contoured on the TRUS and MRI were 26.6cc (range: 12.6∼41.3cc), and 27.4 cc (range: 14.3∼50.0cc), respectively. Axial MRI thicknesses (range: 3.5∼8.1mm) did not significantly affect the contoured volume or the number of seeds required on the preplan (R2 = 0.0002 and 0.0012, respectively). Four of the MRI sequences (AX-T2, AX-T2-Whole-Pelvis, AX-T2-FSE, and AXIALT2- Hi-Res) showed statistically significant better prostate volume agreement with TRUS than the other seven sequences (P <0.01). Nomogram overlay between the MRI and TRUS preplans showed good agreement; indicating volumes contoured on MRI preplan scan reliably predict how many seeds are needed for implant. Conclusion: Although MRI does not allow for determination of the actual implant geometry, it can give reliable volumes for seed ordering purposes. Our future work will investigate if MRI is sufficient to reliably replace TRUS preplanning in patients where preplan TRUS may be technically challenging.« less
WE-F-16A-02: Design, Fabrication, and Validation of a 3D-Printed Proton Filter for Range Spreading
DOE Office of Scientific and Technical Information (OSTI.GOV)
Remmes, N; Courneyea, L; Corner, S
2014-06-15
Purpose: To design, fabricate and test a 3D-printed filter for proton range spreading in scanned proton beams. The narrow Bragg peak in lower-energy synchrotron-based scanned proton beams can result in longer treatment times for shallow targets due to energy switching time and plan quality degradation due to minimum monitor unit limitations. A filter with variable thicknesses patterned on the same scale as the beam's lateral spot size will widen the Bragg peak. Methods: The filter consists of pyramids dimensioned to have a Gaussian distribution in thickness. The pyramids are 2.5mm wide at the base, 0.6 mm wide at the peak,more » 5mm tall, and are repeated in a 2.5mm pseudo-hexagonal lattice. Monte Carlo simulations of the filter in a proton beam were run using TOPAS to assess the change in depth profiles and lateral beam profiles. The prototypes were constrained to a 2.5cm diameter disk to allow for micro-CT imaging of promising prototypes. Three different 3D printers were tested. Depth-doses with and without the prototype filter were then measured in a ~70MeV proton beam using a multilayer ion chamber. Results: The simulation results were consistent with design expectations. Prototypes printed on one printer were clearly unacceptable on visual inspection. Prototypes on a second printer looked acceptable, but the micro-CT image showed unacceptable voids within the pyramids. Prototypes from the third printer appeared acceptable visually and on micro-CT imaging. Depth dose scans using the prototype from the third printer were consistent with simulation results. Bragg peak width increased by about 3x. Conclusions: A prototype 3D printer pyramid filter for range spreading was successfully designed, fabricated and tested. The filter has greater design flexibility and lower prototyping and production costs compared to traditional ridge filters. Printer and material selection played a large role in the successful development of the filter.« less
Elschot, Mattijs; Nijsen, Johannes F W; Lam, Marnix G E H; Smits, Maarten L J; Prince, Jip F; Viergever, Max A; van den Bosch, Maurice A A J; Zonnenberg, Bernard A; de Jong, Hugo W A M
2014-10-01
Radiation pneumonitis is a rare but serious complication of radioembolic therapy of liver tumours. Estimation of the mean absorbed dose to the lungs based on pretreatment diagnostic (99m)Tc-macroaggregated albumin ((99m)Tc-MAA) imaging should prevent this, with administered activities adjusted accordingly. The accuracy of (99m)Tc-MAA-based lung absorbed dose estimates was evaluated and compared to absorbed dose estimates based on pretreatment diagnostic (166)Ho-microsphere imaging and to the actual lung absorbed doses after (166)Ho radioembolization. This prospective clinical study included 14 patients with chemorefractory, unresectable liver metastases treated with (166)Ho radioembolization. (99m)Tc-MAA-based and (166)Ho-microsphere-based estimation of lung absorbed doses was performed on pretreatment diagnostic planar scintigraphic and SPECT/CT images. The clinical analysis was preceded by an anthropomorphic torso phantom study with simulated lung shunt fractions of 0 to 30 % to determine the accuracy of the image-based lung absorbed dose estimates after (166)Ho radioembolization. In the phantom study, (166)Ho SPECT/CT-based lung absorbed dose estimates were more accurate (absolute error range 0.1 to -4.4 Gy) than (166)Ho planar scintigraphy-based lung absorbed dose estimates (absolute error range 9.5 to 12.1 Gy). Clinically, the actual median lung absorbed dose was 0.02 Gy (range 0.0 to 0.7 Gy) based on posttreatment (166)Ho-microsphere SPECT/CT imaging. Lung absorbed doses estimated on the basis of pretreatment diagnostic (166)Ho-microsphere SPECT/CT imaging (median 0.02 Gy, range 0.0 to 0.4 Gy) were significantly better predictors of the actual lung absorbed doses than doses estimated on the basis of (166)Ho-microsphere planar scintigraphy (median 10.4 Gy, range 4.0 to 17.3 Gy; p < 0.001), (99m)Tc-MAA SPECT/CT imaging (median 2.5 Gy, range 1.2 to 12.3 Gy; p < 0.001), and (99m)Tc-MAA planar scintigraphy (median 5.5 Gy, range 2.3 to 18.2 Gy; p < 0.001). In clinical practice, lung absorbed doses are significantly overestimated by pretreatment diagnostic (99m)Tc-MAA imaging. Pretreatment diagnostic (166)Ho-microsphere SPECT/CT imaging accurately predicts lung absorbed doses after (166)Ho radioembolization.
Kaminsky, David A; Daud, Anees; Chapman, David G
2014-10-01
Ventilation heterogeneity (VH) has been linked to airway responsiveness (AR) based on various measures of VH involving inert gas washout, forced oscillation and lung imaging. We explore whether VH at baseline, as measured by the simple ratio of single breath alveolar volume to plethysmographically determined total lung capacity (VA/TLC), would correlate with AR as measured by methacholine challenge testing. We analysed data from spirometry, lung volumes, diffusing capacity and methacholine challenge to derive the VA/TLC and the dose-response slope (DRS) of forced expiratory volume in 1 s (DRS-FEV1) during methacholine challenge from 136 patients. We separated out airway closure versus narrowing by examining the DRS for forced vital capacity (DRS-FVC) and the DRS for FEV1/FVC (DRS-FEV1/FVC), respectively. Similarly, we calculated the DRS for sGaw (DRS-sGaw) as another measure of airway narrowing. We performed statistical analysis using Spearman rank correlation and multifactor linear regression using a backward stepwise modelling procedure. We found that the DRS-FEV1 correlated with baseline VA/TLC (rho = -0.26, P < 0.01), and VA/TLC and FEV1 were independently associated with DRS-FEV1 (R(2) = 0.14, P = 0.01). In addition, VA/TLC was associated with both airway narrowing and closure in response to methacholine. These results confirm that baseline VA/TLC is associated with AR, and reflects both airway closure and airway narrowing following methacholine challenge. © 2014 Asian Pacific Society of Respirology.
Zhao, Yantao; Han, Liwei; Yan, Jun; Li, Zhonghai; Wang, Fuli; Xia, Yang; Hou, Shuxun; Zhong, Hongbin; Zhang, Feimin; Gu, Ning
2017-01-01
Injectable gelatin gels offer an attractive option for filling bone defects. The challenge is to fabricate gelatin gels with optimal gelation properties, which can be irradiation sterilized. Here, a gelatin-water-glycerol (GWG) gel is reported for use as a broad-spectrum injectable carrier. This ternary gel is high in glycerol and low in water, and remains stable after gamma irradiation at doses (25 kGy). As an injectable gel, it remains a viscous solution at gelatin concentrations ≤2.0%, at room temperature. Its storage modulus increases dramatically and eventually exceeds the loss modulus around 46-50 °C, indicating a transition from a liquid-like state to an elastic gel-like state. This ternary gel ranges significantly in terms of storage modulus (12-1700 Pa) while demonstrating a narrow pH range (5.58-5.66), depending on the gelatin concentration. Therefore, it can be loaded with a variety of materials. It is highly cytocompatible compared with saline in vivo and culture media in vitro. When loaded with demineralized bone matrix, the composites show favorable injectability, and excellent osteogenesis performance, after irradiation. These features can be attributed to high hydrophilicity and fast degradability. These findings justify that this ternary gel is promising as an irradiation-sterilized and universal injectable delivery system. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Two-dimensional silicon-based detectors for ion beam therapy
NASA Astrophysics Data System (ADS)
Martišíková, M.; Granja, C.; Jakůbek, J.; Hartmann, B.; Telsemeyer, J.; Huber, L.; Brons, S.; Pospíšil, S.; Jäkel, O.
2012-02-01
Radiation therapy with ion beams is a highly precise kind of cancer treatment. As ion beams traverse material, the highest ionization density occurs at the end of their path. Due to this Bragg-peak, ion beams enable higher dose conformation to the tumor and increased sparing of the surrounding tissue, in comparison to standard radiation therapy using high energy photons. Ions heavier than protons offer in addition increased biological effectiveness and lower scattering. The Heidelberg Ion Beam Therapy Center (HIT) is a state-of-the-art ion beam therapy facility and the first hospital-based facility in Europe. It provides proton and carbon ion treatments. A synchrotron is used for ion acceleration. For dose delivery to the patient, narrow pencil-like beams are scanned over the target volume.
NASA Astrophysics Data System (ADS)
Sánchez-Doblado, Francisco; Capote, Roberto; Leal, Antonio; Roselló, Joan V.; Lagares, Juan I.; Arráns, Rafael; Hartmann, Günther H.
2005-03-01
Intensity modulated radiotherapy (IMRT) has become a treatment of choice in many oncological institutions. Small fields or beamlets with sizes of 1 to 5 cm2 are now routinely used in IMRT delivery. Therefore small ionization chambers (IC) with sensitive volumes <=0.1 cm3are generally used for dose verification of an IMRT treatment. The measurement conditions during verification may be quite different from reference conditions normally encountered in clinical beam calibration, so dosimetry of these narrow photon beams pertains to the so-called non-reference conditions for beam calibration. This work aims at estimating the error made when measuring the organ at risk's (OAR) absolute dose by a micro ion chamber (μIC) in a typical IMRT treatment. The dose error comes from the assumption that the dosimetric parameters determining the absolute dose are the same as for the reference conditions. We have selected two clinical cases, treated by IMRT, for our dose error evaluations. Detailed geometrical simulation of the μIC and the dose verification set-up was performed. The Monte Carlo (MC) simulation allows us to calculate the dose measured by the chamber as a dose averaged over the air cavity within the ion-chamber active volume (Dair). The absorbed dose to water (Dwater) is derived as the dose deposited inside the same volume, in the same geometrical position, filled and surrounded by water in the absence of the ion chamber. Therefore, the Dwater/Dair dose ratio is the MC estimator of the total correction factor needed to convert the absorbed dose in air into the absorbed dose in water. The dose ratio was calculated for the μIC located at the isocentre within the OARs for both clinical cases. The clinical impact of the calculated dose error was found to be negligible for the studied IMRT treatments.
Narrow-band double-pass superluminescent diodes emitting at 1060 nm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lobintsov, A A; Perevozchikov, M V; Shramenko, M V
2009-09-30
Experimental data are presented which show that double-pass superluminescent diodes (SLDs) with fibre Bragg grating (FBG) based spectrally selective external reflectors offer emission linewidths in the range 0.1-1.0 nm, i.e., one to two orders of magnitude narrower in comparison with conventional SLDs and considerably broader in comparison with single-frequency semiconductor lasers. Their optical power at the single-mode fibre output reaches 5.0-8.0 mW, and can be raised to 50 mW using a semiconductor optical amplifier. (lasers)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piot, P.; Sun, Y. -E; Maxwell, T. J.
2011-06-27
We experimentally demonstrate the production of narrow-band (δf/f ~ =20% at f ~ = 0.5 THz) THz transition radiation with tunable frequency over [0.37, 0.86] THz. The radiation is produced as a train of sub-picosecond relativistic electron bunches transits at the vacuum-aluminum interface of an aluminum converter screen. In addition, we show a possible application of modulated beams to extend the dynamical range of a popular bunch length diagnostic technique based on the spectral analysis of coherent radiation.
NASA Astrophysics Data System (ADS)
Moretto, G.; Kuhn, J.; Langlois, M.; Berdugyna, S.; Tallon, M.
2017-09-01
Telescopes larger than currently planned 30-m class instruments must break the mass-aperture scaling relationship of the Keck-generation of multi-segmented telescopes. Partially filled aperture, but highly redundant baseline interferometric instruments may achieve both large aperture and high dynamic range. The PLANETS FOUNDATION group has explored hybrid telescope-interferometer concepts for narrow-field optical systems that exhibit coronagraphic performance over narrow fields-of-view. This paper describes how the Colossus and Exo-Life Finder telescope designs achieve 10x lower moving masses than current Extremely Large Telescopes.
NASA Astrophysics Data System (ADS)
Hopper, E.; Gaherty, J. B.; Shillington, D. J.
2016-12-01
Continental extension comes in many guises, often described in terms of two endmembers. Narrow rifting is typified by a rift valley narrower than lithospheric thickness (50-100 km), presumed to result in steep lateral changes in crustal and lithospheric topography; wide rifting by a broad zone (<1000 km) of normal faulting associated with much smaller topographic gradients. A type example for the former is the East African Rift Valley; for the latter, the Basin and Range in the western U.S.A. An important control on rift development is the state of the lithosphere: for example, its strength and thickness. We analyse common conversion point stacked Sp converted wave images of the lithosphere beneath rift systems in the contiguous U.S., both the wide Basin and Range, and narrow rift systems such as the Rio Grande Rift and Salton Trough. We use Sp waves recorded by EarthScope's Transportable Array and other available permanent and temporary broadband stations. Beneath the Basin and Range, we observe a very strong, shallow velocity decrease (the lithosphere-asthenosphere boundary, or LAB) that is relatively uniform over 100s of km. The strength of this feature indicates melt has ponded at this transition. We have not observed a clear relationship between lithospheric thickness beneath the Basin and Range, and total degree of extension, current extension rate, or age since surface volcanism. Beneath narrow rifts in the western U.S., however, more localised thinning of the lithosphere has been observed. We also compare these observations with seismic images of the Malawi Rift, at the southern end of the Western Branch of the East African Rift System, using broadband data acquired as part of the Study of Extension and MaGmatism in Malawi aNd Tanzania (SEGMeNT) experiment. The Malawi Rift is extending slowly in a magma-poor region of relatively strong lithosphere. We constrain the pattern of plate-scale extension by observations of crustal thinning, and image complex variations in deeper lithospheric structure.
NASA Astrophysics Data System (ADS)
Hopper, E.; Gaherty, J. B.; Shillington, D. J.
2017-12-01
Continental extension comes in many guises, often described in terms of two endmembers. Narrow rifting is typified by a rift valley narrower than lithospheric thickness (50-100 km), presumed to result in steep lateral changes in crustal and lithospheric topography; wide rifting by a broad zone (<1000 km) of normal faulting associated with much smaller topographic gradients. A type example for the former is the East African Rift Valley; for the latter, the Basin and Range in the western U.S.A. An important control on rift development is the state of the lithosphere: for example, its strength and thickness. We analyse common conversion point stacked Sp converted wave images of the lithosphere beneath rift systems in the contiguous U.S., both the wide Basin and Range, and narrow rift systems such as the Rio Grande Rift and Salton Trough. We use Sp waves recorded by EarthScope's Transportable Array and other available permanent and temporary broadband stations. Beneath the Basin and Range, we observe a very strong, shallow velocity decrease (the lithosphere-asthenosphere boundary, or LAB) that is relatively uniform over 100s of km. The strength of this feature indicates melt has ponded at this transition. We have not observed a clear relationship between lithospheric thickness beneath the Basin and Range, and total degree of extension, current extension rate, or age since surface volcanism. Beneath narrow rifts in the western U.S., however, more localised thinning of the lithosphere has been observed. We also compare these observations with seismic images of the Malawi Rift, at the southern end of the Western Branch of the East African Rift System, using broadband data acquired as part of the Study of Extension and MaGmatism in Malawi aNd Tanzania (SEGMeNT) experiment. The Malawi Rift is extending slowly in a magma-poor region of relatively strong lithosphere. We constrain the pattern of plate-scale extension by observations of crustal thinning, and image complex variations in deeper lithospheric structure.
US antibiotic stewardship and penicillin allergy.
Wada, Kara J; Calhoun, Karen H
2017-06-01
The purpose of this review is to improve otolaryngologists' antibiotic stewardship by detailing current approaches to penicillin allergy. Although up to 15% of hospitalized patients in the United States have a penicillin allergy recorded on their charts, fewer than 10% of these have a true penicillin allergy. Using a combination of a detailed allergy history, skin testing and graded-dose administration, many patients whose charts say 'penicillin-allergic' can safely be treated with penicillin and cross-reacting antibiotics. This permits use of narrower-spectrum antibiotics and saves money.
Eagle, Benjamin; Williams, David J; Dingley, John
2017-08-01
An ideal electronic anesthesia recording system would be capable of not only recording physiological data but also injectable drug doses given, including those given incrementally from one syringe, without recourse to manual data entry. We compared 2 prototype devices which wirelessly recognized individual syringes and measured changes in their plunger positions via 2 different optical noncontact means, allowing calculation of incremental drug doses given. Both devices incorporated a radio-frequency identification reader, which wirelessly read a unique code from a radio-frequency identification tag within syringe drug labels. A custom-designed cradle oriented any inserted 1-mL to 20-mL syringe in a repeatable position. The "laser" device had a moving laser beam broken by the end of the syringe plunger. The infrared (IR) device measured time of travel of IR light from a sender to a syringe plunger and back to a receiver. Both devices could therefore determine the drug and volume administered since the previous occasion when any syringe had been used. For each syringe size of 1, 2, 5, 10, and 20 mL, 121 plunger-length measurements were made over their full range, with each machine against a reference method of water filling and weighing using a randomized de Bruijn sequence. For every syringe size, the laser device showed greater accuracy and precision, lower bias, and narrower limits of agreement (95% confidence intervals = bias ± 1.96 SD) than the IR device when compared to the reference method. For all syringe sizes, the range of bias was -0.05 to 0.32 mL for the laser and -2.42 to 1.38 mL for the IR. Lin concordance correlation coefficient values for the IR versus reference methods ranged from 0.6259 to 0.9255, with the lowest coefficients seen in syringes with the shortest distance of plunger travel (2 and 5 mL), while in laser versus reference comparisons, these coefficients were similar (0.9641-0.9981) over all syringe lengths. Both devices measured syringe volume changes, demonstrating potential for measuring incremental drug doses, recording these, and also the time of each measurement. The IR device had no moving parts, which would be advantageous in a clinical situation. However, the current embodiment was not deemed accurate enough for clinical use, potentially remediable through improvements in hardware and software design. The laser device showed high accuracy and precision over all syringe sizes and contained volumes, and was considered potentially accurate enough for clinical use with suitable development.
Mutagenic effects of gamma rays on soybean (Glycine max L.) germination and seedlings
NASA Astrophysics Data System (ADS)
Kusmiyati, F.; Sutarno; Sas, M. G. A.; Herwibawa, B.
2018-01-01
Narrow genetic diversity is a main problem restricting the progress of soybean breeding. One way to improve genetic diversity of plant is through mutation. The purpose of this study was to investigate effect of different dose of gamma rays as induced mutagen on physiological, morphological, and anatomical markers during seed germination and seedling growth of soybean. Seeds of soybean cultivars Dering-1 were irradiated with 11 doses of gamma rays (0, 5, 10, 20, 40, 80, 160, 320, 640, 1280, and 2560 Gy [Gray]. The research design was arranged in a completely randomized block design in three replicates. Results showed that soybean seed exposed at high doses (640, 1280, and 2560 Gy) did not survive more than 20 days, the doses were then removed from anatomical evaluation. Higher doses of gamma rays siginificantly reduced germination percentage at the first count and final count, coefficient of germination velocity, germination rate index, germination index, seedling height and seedling root length, and significantly increased mean germination time, first day of germination, last day of germination, and time spread of germination. However, the effects of gamma rays were varies for density, width, and length of stomata. The LD50 obtained based on survival percentage was 314.78 Gy. It can be concluded that very low and low doses of gamma rays (5-320 Gy) might be used to study the improvement of soybean diversity.
High and low energy gamma beam dump designs for the gamma beam delivery system at ELI-NP
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yasin, Zafar, E-mail: zafar.yasin@eli-np.ro; Matei, Catalin; Ur, Calin A.
The Extreme Light Infrastructure - Nuclear Physics (ELI-NP) is under construction in Magurele, Bucharest, Romania. The facility will use two 10 PW lasers and a high intensity, narrow bandwidth gamma beam for stand-alone and combined laser-gamma experiments. The accurate estimation of particle doses and their restriction within the limits for both personel and general public is very important in the design phase of any nuclear facility. In the present work, Monte Carlo simulations are performed using FLUKA and MCNPX to design 19.4 and 4 MeV gamma beam dumps along with shielding of experimental areas. Dose rate contour plots from both FLUKAmore » and MCNPX along with numerical values of doses in experimental area E8 of the facility are performed. The calculated doses are within the permissible limits. Furthermore, a reasonable agreement between both codes enhances our confidence in using one or both of them for future calculations in beam dump designs, radiation shielding, radioactive inventory, and other calculations releated to radiation protection. Residual dose rates and residual activity calculations are also performed for high-energy beam dump and their effect is negligible in comparison to contributions from prompt radiation.« less
Vitamin K for improved anticoagulation control in patients receiving warfarin.
Mahtani, Kamal R; Heneghan, Carl J; Nunan, David; Roberts, Nia W
2014-05-15
Effective use of warfarin involves keeping the international normalised ratio (INR) within a relatively narrow therapeutic range. However, patients respond widely to their dose of warfarin. Overcoagulation can lead to an increased risk of excessive bleeding, while undercoagulation can lead to increased clot formation. There is some evidence that patients with a variable response to warfarin may benefit from a concomitant low dose of vitamin K. To assess the effects of concomitant supplementation of low-dose oral vitamin K for anticoagulation control in patients being initiated on or taking a maintenance dose of warfarin. To identify previous reviews, we searched the Database of Abstracts of Reviews of Effects (DARE via The Cochrane Library, Wiley) (Issue 2, 2011). To identify primary studies, we searched the Cochrane Central Register of Controlled Trials (CENTRAL via The Cochrane Library, Wiley) (Issue 2, 2014), Ovid MEDLINE (R) In-Process & Other Non-Indexed Citations database and Ovid MEDLINE (R) (OvidSP) (1946 to 25 February 2014), Embase (OvidSP) (1974 to week 8 of 2014), Science Citation Index Expanded™ & Conference Proceedings Citation Index - Science (Web of Science™) (1945 to 27 February 2014), and the NHS Economics Evaluations Database (NHS EED) (via The Cochrane Library, Wiley) (Issue 2, 2014). We did not apply any language or date restrictions. We used additional methods to identify grey literature and ongoing studies. Randomised controlled trials comparing the addition of vitamin K versus placebo in patients initiating warfarin or already taking warfarin. Two review authors independently selected and extracted data from included studies. When disagreement arose, a third author helped reached a consensus. We also assessed risk of bias. We identified two studies with a total of 100 participants for inclusion in the review. We found the overall risk of bias to be unclear in a number of domains. Neither study reported the time taken to the first INR in range. Only one study (70 participants) reported the mean time in therapeutic range as a percentage. This study found that in the group of participants deemed to have poor INR control, the addition of 150 micrograms (mcg) oral vitamin K significantly improved anticoagulation control in those with unexplained instability of response to warfarin. The second study (30 participants) reported the effect of 175 mcg oral vitamin K versus placebo on participants with high variability in their INR levels. The study concluded that vitamin K supplementation did not significantly improve the stability of anticoagulation for participants on chronic anticoagulation therapy. However, the study was only available in abstract form, and communication with the lead author confirmed that there were no further publications. Therefore, we interpreted this conclusion with caution. Neither study reported any thromboembolic events, haemorrhage, or death from the addition of vitamin K supplementation. Two included studies in this review compared whether the addition of a low dose (150 to 175 mcg) of vitamin K given to participants with a high-variability response to warfarin improved their INR control. One study demonstrated a significant improvement, while another smaller study (published in abstract only) suggested no overall benefit. Currently, there are insufficient data to suggest an overall benefit. Larger, higher quality trials are needed to examine if low-dose vitamin K improves INR control in those starting or already taking warfarin.
Hagmar, Lars; Wirfält, Elisabet; Paulsson, Birgit; Törnqvist, Margareta
2005-02-07
The variation in dietary exposure to acrylamide (AA) has been studied through measurement of hemoglobin adduct levels from AA, as a measurement of internal dose, in a sample from the blood bank of the Malmö Diet and Cancer Cohort (n=28,098). The blood donors are well characterised with regard to their food habits, and 142 individuals were selected to obtain highest possible variation in the adduct levels from AA (none, random or high intake of coffee, fried potato, crisp bread and snacks, food items estimated to have high levels of AA). Among 70 non-smokers the AA-adduct levels varied by a factor of 5, and ranged between 0.02 and 0.1 nmol/g, with considerable overlap in AA-adduct levels between the different dietary groups. There was a significant difference between men with high dietary exposure to AA compared to men with low dietary exposure (P=0.04). No such difference was found for women. As expected a higher level (range: 0.03-0.43 nmol/g) of the AA-adduct, due to AA in tobacco smoke, was found in smokers. Smoking women with high dietary exposure to AA had significantly higher AA-adduct levels compared to smoking women with low dietary exposure (P=0.01). No such significant difference was found in smoking men. The median hemoglobin (Hb) adduct level in the randomly selected group of non-smokers was compatible with earlier studies (0.031 nmol/g). The variation in the average internal dose, measured as Hb adducts, was somewhat smaller than estimated for daily intake by food consumption questionnaires in other studies. Thus, the observed relatively narrow inter-individual variation in AA-adduct levels means that estimates of individual dietary AA intake have to be very precise if they should be useful in future cancer epidemiology.
Focal spot motion of linear accelerators and its effect on portal image analysis.
Sonke, Jan-Jakob; Brand, Bob; van Herk, Marcel
2003-06-01
The focal spot of a linear accelerator is often considered to have a fully stable position. In practice, however, the beam control loop of a linear accelerator needs to stabilize after the beam is turned on. As a result, some motion of the focal spot might occur during the start-up phase of irradiation. When acquiring portal images, this motion will affect the projected position of anatomy and field edges, especially when low exposures are used. In this paper, the motion of the focal spot and the effect of this motion on portal image analysis are quantified. A slightly tilted narrow slit phantom was placed at the isocenter of several linear accelerators and images were acquired (3.5 frames per second) by means of an amorphous silicon flat panel imager positioned approximately 0.7 m below the isocenter. The motion of the focal spot was determined by converting the tilted slit images to subpixel accurate line spread functions. The error in portal image analysis due to focal spot motionwas estimated by a subtraction of the relative displacement of the projected slit from the relative displacement of the field edges. It was found that the motion of the focal spot depends on the control system and design of the accelerator. The shift of the focal spot at the start of irradiation ranges between 0.05-0.7 mm in the gun-target (GT) direction. In the left-right (AB) direction the shift is generally smaller. The resulting error in portal image analysis due to focal spotmotion ranges between 0.05-1.1 mm for a dose corresponding to two monitor units (MUs). For 20 MUs, the effect of the focal spot motion reduces to 0.01-0.3 mm. The error in portal image analysis due to focal spot motion can be reduced by reducing the applied dose rate.
FINAL SAFETY ANALYSIS REPORT--SNAP 1A RADIOISOTOPE FUELED THERMOELECTRIC GENERATOR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dix, G.P.
1960-06-30
The safety aspects involved in utilizing the Task 2 radioisotope-powered thermoelectric generator in a terrestrial satellite are described. It is based upon a generalized satellite mission having a 600-day orbital lifetime. A description of the basic design of the generator is presented in order to establish the analytical model. This includes the generator design, radiocerium fuel properties, and the fuel core. The transport of the generator to the launch site is examined, including the shipping cask, shipping procedures, and shipping hazards. A description of ground handling and vehicle integration is presented including preparation for fuel transfer, transfer, mating of generatorsmore » to final stage, mating final stage to booster, and auxiliary support equipment. The flight vehicle is presented to complete the analytical model. Contained in this chapter are descriptions of the booster-sustainer, final stage, propellants, and built-in safety systems. The typical missile range is examined with respect to the launch complex and range safety characteristics. The shielding of the fuel is discussed and includes both dose rates and shield thicknesses required. The bare core, shielded generator, fuel transfer operation and dose rates for accidental conditions are treated. mechanism of re-entry from the successful mission is covered. Radiocerium inventories with respect to time and the chronology of re-entry are specifically treated. The multiplicity of conditions for aborted missions is set forth. The definition of aborted missions is treated first in order to present the initial conditions. Following this, a definition of the forces imposed upon the generator is presented. The aborted missions is presented. A large number of initial vehicle failure cases is narrowed down into categories of consequences. Since stratospheric injection of fuel results in cases where the fuel is not contained after re-entry, an extensive discussion of the fall-out mechanism is presented. (auth)« less
Population Pharmacokinetic Analyses of Lithium: A Systematic Review.
Methaneethorn, Janthima
2018-02-01
Even though lithium has been used for the treatment of bipolar disorder for several decades, its toxicities are still being reported. The major limitation in the use of lithium is its narrow therapeutic window. Several methods have been proposed to predict lithium doses essential to attain therapeutic levels. One of the methods used to guide lithium therapy is population pharmacokinetic approach which accounts for inter- and intra-individual variability in predicting lithium doses. Several population pharmacokinetic studies of lithium have been conducted. The objective of this review is to provide information on population pharmacokinetics of lithium focusing on nonlinear mixed effect modeling approach and to summarize significant factors affecting lithium pharmacokinetics. A literature search was conducted from PubMed database from inception to December, 2016. Studies conducted in humans, using lithium as a study drug, providing population pharmacokinetic analyses of lithium by means of nonlinear mixed effect modeling, were included in this review. Twenty-four articles were identified from the database. Seventeen articles were excluded based on the inclusion and exclusion criteria. A total of seven articles were included in this review. Of these, only one study reported a combined population pharmacokinetic-pharmacodynamic model of lithium. Lithium pharmacokinetics were explained using both one- and two-compartment models. The significant predictors of lithium clearance identified in most studies were renal function and body size. One study reported a significant effect of age on lithium clearance. The typical values of lithium clearance ranged from 0.41 to 9.39 L/h. The magnitude of inter-individual variability on lithium clearance ranged from 12.7 to 25.1%. Only two studies evaluated the models using external data sets. Model methodologies in each study are summarized and discussed in this review. For future perspective, a population pharmacokinetic-pharmacodynamic study of lithium is recommended. Moreover, external validation of previously published models should be performed.
High brightness diode lasers controlled by volume Bragg gratings
NASA Astrophysics Data System (ADS)
Glebov, Leonid
2017-02-01
Volume Bragg gratings (VBGs) recorded in photo-thermo-refractive (PTR) glass are holographic optical elements that are effective spectral and angular filters withstanding high power laser radiation. Reflecting VBGs are narrow-band spectral filters while transmitting VBGs are narrow-band angular filters. The use of these optical elements in external resonators of semiconductor lasers enables extremely resonant feedback that provides dramatic spectral and angular narrowing of laser diodes radiation without significant power and efficiency penalty. Spectral narrowing of laser diodes by reflecting VBGs demonstrated in wide spectral region from near UV to 3 μm. Commercially available VBGs have spectral width ranged from few nanometers to few tens of picometers. Efficient spectral locking was demonstrated for edge emitters (single diodes, bars, modules, and stacks), vertical cavity surface emitting lasers (VCSELs), grating coupled surface emitting lasers (GCSELs), and interband cascade lasers (ICLs). The use of multiplexed VBGs provides multiwavelength emission from a single emitter. Spectrally locked semiconductor lasers demonstrated CW power from milliwatts to a kilowatt. Angular narrowing by transmitting VBGs enables single transverse mode emission from wide aperture diode lasers having resonators with great Fresnel numbers. This feature provides close to diffraction limit divergence along a slow axis of wide stripe edge emitters. Radiation exchange between lasers by means of spatially profiled or multiplexed VBGs enables coherent combining of diode lasers. Sequence of VBGs or multiplexed VBGs enable spectral combining of spectrally narrowed diode lasers or laser modules. Thus the use of VBGs for diode lasers beam control provides dramatic increase of brightness.
Song, Mee Hyun; Bae, Mi Ran; Kim, Hee Nam; Lee, Won-Sang; Yang, Won Sun; Choi, Jae Young
2010-08-01
Cochlear implantation in patients with narrow internal auditory canal (IAC) can result in variable outcomes; however, preoperative evaluations have limitations in accurately predicting outcomes. In this study, we analyzed the outcomes of cochlear implantation in patients with narrow IAC and correlated the intracochlear electrically evoked auditory brainstem response (EABR) findings to postoperative performance to determine the prognostic significance of intracochlear EABR. Retrospective case series at a tertiary hospital. Thirteen profoundly deaf patients with narrow IAC who received cochlear implantation from 2002 to 2008 were included in this study. Postoperative performance was evaluated after at least 12 months of follow-up, and postoperative intracochlear EABR was measured to determine its correlation with outcome. The clinical significance of electrically evoked compound action potential (ECAP) was also analyzed. Patients with narrow IAC showed postoperative auditory performances ranging from CAP 0 to 4 after cochlear implantation. Intracochlear EABR measured postoperatively demonstrated prognostic value in the prediction of long-term outcomes, whereas ECAP measurements failed to show a significant correlation with outcome. Consistent with the advantages of intracochlear EABR over extracochlear EABR, this study demonstrates that intracochlear EABR has prognostic significance in predicting long-term outcomes in patients with narrow IAC. Intracochlear EABR measured either intraoperatively or in the early postoperative period may play an important role in deciding whether to continue with auditory rehabilitation using a cochlear implant or to switch to an auditory brainstem implant so as not to miss the optimal timing for language development.
Spatial variation of dosimetric leaf gap and its impact on dose delivery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumaraswamy, Lalith K., E-mail: Lalith.Kumaraswamy@roswellpark.org; Schmitt, Jonathan D.; Bailey, Daniel W.
Purpose: During dose calculation, the Eclipse treatment planning system (TPS) retracts the multileaf collimator (MLC) leaf positions by half of the dosimetric leaf gap (DLG) value (measured at central axis) for all leaf positions in a dynamic MLC plan to accurately model the rounded leaf ends. The aim of this study is to map the variation of DLG along the travel path of each MLC leaf pair and quantify how this variation impacts delivered dose. Methods: 6 MV DLG values were measured for all MLC leaf pairs in increments of 1.0 cm (from the line intersecting the CAX and perpendicularmore » to MLC motion) to 13.0 cm off axis distance at dmax. The measurements were performed on two Varian linear accelerators, both employing the Millennium 120-leaf MLCs. The measurements were performed at several locations in the beam with both a Sun Nuclear MapCHECK device and a PTW pinpoint ion chamber. Results: The measured DLGs for the middle 40 MLC leaf pairs (each 0.5 cm width) at positions along a line through the CAX and perpendicular to MLC leaf travel direction were very similar, varying maximally by only 0.2 mm. The outer 20 MLC leaf pairs (each 1.0 cm width) have much lower DLG values, about 0.3–0.5 mm lower than the central MLC leaf pair, at their respective central line position. Overall, the mean and the maximum variation between the 0.5 cm width leaves and the 1.0 cm width leaf pairs are 0.32 and 0.65 mm, respectively. Conclusions: The spatial variation in DLG is caused by the variation of intraleaf transmission through MLC leaves. Fluences centered on the CAX would not be affected since DLG does not vary; but any fluences residing significantly off axis with narrow sweeping leaves may exhibit significant dose differences. This is due to the fact that there are differences in DLG between the true DLG exhibited by the 1.0 cm width outer leaves and the constant DLG value utilized by the TPS for dose calculation. Since there are large differences in DLG between the 0.5 cm width leaf pairs and 1.0 cm width leaf pairs, there is a need to correct the TPS plans, especially those with high modulation (narrow dynamic MLC gap), with 2D variation of DLG.« less
Ultra-narrow-linewidth Brillouin/erbium fiber laser
NASA Astrophysics Data System (ADS)
Chen, Mo; Wang, Chenyu; Wang, Jianfei; Luo, Hong; Meng, Zhou
2018-02-01
Ultra-narrow-linewidth lasers are of great interest in many applications, such as precise spectroscopy, optical communications, and sensors. Stimulated Brillouin scattering (SBS), as one of the main nonlinear effects in fibers, is capable of generating narrow-linewidth light emission. We establish a compact Brillouin/erbium fiber laser (BEFL) utilizing 4-m erbium-doped fiber as both the Brillouin gain and linear media. A 360-kHz-linewidth laser diode is injected into the cavity as the Brillouin pump (BP) light and generates Brillouin Stokes lasing light. Both of the phase noise of the BP and BEFL output are measured by a high-accuracy unbalanced Michelson interferometer. It is demonstrated that 53- dB phase noise reduction is achieved after the BP is transferred into Brillouin Stokes emission. The linewidth of the BEFL is indicated at Hz-range by both calculation and experiment.
Spectral properties of rf emission from high Tc films
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jung, G.; Konopka, J.; Vitale, S.
1990-09-15
Spectral properties of rf radiation from intrinsic Josephson junctions in high {Tc} Y-Ba-Cu-O thin film have been measured in the frequency range up to 1.5 GHz. Narrow emission lines with the 3 dB bandwidth of the order of 20 MHz were detected indicating that Josephson clusters radiate coherently. Synchronization conditions are determined by dc current and external magnetic field bias. Frequency locking of radiation to external resonant circuit was also observed. Spectral line narrowing due to resonant lock was distinguished from the coherence-induced narrowing by different tuning properties of the emission line. Noncoherent Josephson radiation manifests itself as a broadbandmore » background noise increase. A pronounced 1/{ital f}-like tail sensitive to dc bias and magnetic field was observed in a low frequency part of the spectrum.« less
FEM design and simulation of a short, 10 MV, S-band Linac with Monte Carlo dose simulations.
Baillie, Devin; St Aubin, J; Fallone, B G; Steciw, S
2015-04-01
Current commercial 10 MV Linac waveguides are 1.5 m. The authors' current 6 MV linear accelerator-magnetic resonance imager (Linac-MR) system fits in typical radiotherapy vaults. To allow 10 MV treatments with the Linac-MR and still fit within typical vaults, the authors design a 10 MV Linac with an accelerator waveguide of the same length (27.5 cm) as current 6 MV Linacs. The first design stage is to design a cavity such that a specific experimental measurement for breakdown is applicable to the cavity. This is accomplished through the use of finite element method (FEM) simulations to match published shunt impedance, Q factor, and ratio of peak to mean-axial electric field strength from an electric breakdown study. A full waveguide is then designed and tuned in FEM simulations based on this cavity design. Electron trajectories are computed through the resulting radio frequency fields, and the waveguide geometry is modified by shifting the first coupling cavity in order to optimize the electron beam properties until the energy spread and mean energy closely match values published for an emulated 10 MV Linac. Finally, Monte Carlo dose simulations are used to compare the resulting photon beam depth dose profile and penumbra with that produced by the emulated 10 MV Linac. The shunt impedance, Q factor, and ratio of peak to mean-axial electric field strength are all matched to within 0.1%. A first coupling cavity shift of 1.45 mm produces an energy spectrum width of 0.347 MeV, very close to the published value for the emulated 10 MV of 0.315 MeV, and a mean energy of 10.53 MeV, nearly identical to the published 10.5 MeV for the emulated 10 MV Linac. The depth dose profile produced by their new Linac is within 1% of that produced by the emulated 10 MV spectrum for all depths greater than 1.5 cm. The penumbra produced is 11% narrower, as measured from 80% to 20% of the central axis dose. The authors have successfully designed and simulated an S-band waveguide of length of 27.5 cm capable of producing a 10 MV photon beam. This waveguide operates well within the breakdown threshold determined for the cavity geometry used. The designed Linac produces depth dose profiles similar to those of the emulated 10 MV Linac (waveguide-length of 1.5 m) but yields a narrower penumbra.
FEM design and simulation of a short, 10 MV, S-band Linac with Monte Carlo dose simulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baillie, Devin; Aubin, J. St.; Steciw, S., E-mail: ssteciw@ualberta.ca
2015-04-15
Purpose: Current commercial 10 MV Linac waveguides are 1.5 m. The authors’ current 6 MV linear accelerator–magnetic resonance imager (Linac–MR) system fits in typical radiotherapy vaults. To allow 10 MV treatments with the Linac–MR and still fit within typical vaults, the authors design a 10 MV Linac with an accelerator waveguide of the same length (27.5 cm) as current 6 MV Linacs. Methods: The first design stage is to design a cavity such that a specific experimental measurement for breakdown is applicable to the cavity. This is accomplished through the use of finite element method (FEM) simulations to match publishedmore » shunt impedance, Q factor, and ratio of peak to mean-axial electric field strength from an electric breakdown study. A full waveguide is then designed and tuned in FEM simulations based on this cavity design. Electron trajectories are computed through the resulting radio frequency fields, and the waveguide geometry is modified by shifting the first coupling cavity in order to optimize the electron beam properties until the energy spread and mean energy closely match values published for an emulated 10 MV Linac. Finally, Monte Carlo dose simulations are used to compare the resulting photon beam depth dose profile and penumbra with that produced by the emulated 10 MV Linac. Results: The shunt impedance, Q factor, and ratio of peak to mean-axial electric field strength are all matched to within 0.1%. A first coupling cavity shift of 1.45 mm produces an energy spectrum width of 0.347 MeV, very close to the published value for the emulated 10 MV of 0.315 MeV, and a mean energy of 10.53 MeV, nearly identical to the published 10.5 MeV for the emulated 10 MV Linac. The depth dose profile produced by their new Linac is within 1% of that produced by the emulated 10 MV spectrum for all depths greater than 1.5 cm. The penumbra produced is 11% narrower, as measured from 80% to 20% of the central axis dose. Conclusions: The authors have successfully designed and simulated an S-band waveguide of length of 27.5 cm capable of producing a 10 MV photon beam. This waveguide operates well within the breakdown threshold determined for the cavity geometry used. The designed Linac produces depth dose profiles similar to those of the emulated 10 MV Linac (waveguide-length of 1.5 m) but yields a narrower penumbra.« less
Intensity Variations of Narrow Bands of Solar UV Radiation during Descending Phases of SACs 21-23
NASA Astrophysics Data System (ADS)
Gigolashvili, M.; Kapanadze, N.
2014-12-01
The study of variations of four narrow bands of solar spectral irradiance (SSI) in the ultraviolet (UV) range for period 1981-2008 is presented. Observational data obtained by space-flight missions SORCE, UARS, SME and daily meanings of international sunspot number (ISN) have been used. The investigated data cover the decreasing phases of the solar activity cycles (SACs) 21, 22 and 23. We have revealed a peculiar behavior of intensity variability of some solar ultraviolet spectral lines originated in the solar chromospheres for period corresponding to the declining phase of the solar cycle 23. It is found that variability of emission of different solar spectral narrow bands (289.5 nm, 300.5 nm) does not agree equally well with ISN variability during decreasing phase of the solar activity cycle 23. The negative correlations between total solar irradiance and the solar spectral narrow bands of UV emission (298.5 nm, 300.5 nm) had been revealed. The existence of the negative correlation can be explained by the sensitivity of SSI of some emission lines to the solar global magnetic field.
Qin, Peng; Song, Youjian; Kim, Hyoji; Shin, Junho; Kwon, Dohyeon; Hu, Minglie; Wang, Chingyue; Kim, Jungwon
2014-11-17
Fiber lasers mode-locked with normal cavity dispersion have recently attracted great attention due to large output pulse energy and femtosecond pulse duration. Here we accurately characterized the timing jitter of normal-dispersion fiber lasers using a balanced cross-correlation method. The timing jitter characterization experiments show that the timing jitter of normal-dispersion mode-locked fiber lasers can be significantly reduced by using narrow band-pass filtering (e.g., 7-nm bandwidth filtering in this work). We further identify that the timing jitter of the fiber laser is confined in a limited range, which is almost independent of cavity dispersion map due to the amplifier-similariton formation by insertion of the narrow bandpass filter. The lowest observed timing jitter reaches 0.57 fs (rms) integrated from 10 kHz to 10 MHz Fourier frequency. The rms relative intensity noise (RIN) is also reduced from 0.37% to 0.02% (integrated from 1 kHz to 5 MHz Fourier frequency) by the insertion of narrow band-pass filter.
Murayama, Takashi; Maruyama, Ichiro N
2015-11-01
Animals can survive only within a narrow pH range. This requires continual monitoring of environmental and body-fluid pH. Although a variety of acidic pH sensor molecules have been reported, alkaline pH sensor function is not well understood. This Review describes neuronal alkaline pH sensors, grouped according to whether they monitor extracellular or intracellular alkaline pH. Extracellular sensors include the receptor-type guanylyl cyclase, the insulin receptor-related receptor, ligand-gated Cl- channels, connexin hemichannels, two-pore-domain K+ channels, and transient receptor potential (TRP) channels. Intracellular sensors include TRP channels and gap junction channels. Identification of molecular mechanisms underlying alkaline pH sensing is crucial for understanding how animals respond to environmental alkaline pH and how body-fluid pH is maintained within a narrow range. © 2015 Wiley Periodicals, Inc.
Good, Philipp; Cooper, Thomas; Querci, Marco; Wiik, Nicolay; Ambrosetti, Gianluca; Steinfeld, Aldo
2016-03-01
The spectral specular reflectance of conventional and novel reflective materials for solar concentrators is measured with an acceptance angle of 17.5 mrad over the wavelength range 300-2500 nm at incidence angles 15-60° using a spectroscopic goniometry system. The same experimental setup is used to determine the spectral narrow-angle transmittance of semi-transparent materials for solar collector covers at incidence angles 0-60°. In addition, the angle-resolved surface scattering of reflective materials is recorded by an area-scan CCD detector over the spectral range 350-1050 nm. A comprehensive summary, discussion, and interpretation of the results are included in the associated research article "Spectral reflectance, transmittance, and angular scattering of materials for solar concentrators" in Solar Energy Materials and Solar Cells.
Fixation of virgin lunar surface soil
NASA Technical Reports Server (NTRS)
Conley, J. M.; Frazer, R.; Cannon, W. A.
1972-01-01
Two systems are shown to be suitable for fixing loose particulate soils with a polymer film, without visually detectable disturbance of the soil particle spatial relationships. A two-component system is described, which uses a gas monomer condensible at the soil temperature and a gas phase catalyst acting to polymerize the monomer. A one-component system using a monomer which polymerizes spontaneously on and within the top few millimeters of the soil is also considered. The two-component system employs a simpler apparatus, but it operates over a narrower temperature range (approximately -40 to -10 C). Other two-component systems were identified which may operate at soil temperatures as high as +100 C, at relatively narrow temperature ranges of approximately 30 C. The one-component system was demonstrated to operate successfully with initial soil temperatures from -70 C or lower to +150 C.
Acoustic-assisted fluidic hourglasses
NASA Astrophysics Data System (ADS)
Guimaraes, Tamara; Marin, Alvaro; Kaehler, Christian J.; Barnkob, Rune
2017-11-01
Microfluidic devices are prone to get clogged when suspensions are forced through narrow passages. Such clogging events occur when particles form arches that block the channel. In this work we study the clogging probabilities in a microfluidic hourglass when subject to ultrasound. We measure the clogging probabilities for certain ranges of sound amplitudes and particle-to-neck size ratios in which clogging events are more likely to occur. The ultrasound induces acoustic radiation forces on the suspended particles, leading to particle migration perpendicular to the channel flow direction. The transverse particle rearrangement can significantly reduce the clogging probability by decreasing the chances of arching in the narrowing of the passage. We show that by choosing proper sound actuation conditions, the method is reliable, non-intrusive, preventive, and allows to increase the life of fluidic devices (microfluidic or larger) with particles in a wide range of sizes.
Quantum-Well Thermophotovoltaic Cells
NASA Technical Reports Server (NTRS)
Freudlich, Alex; Ignatiev, Alex
2009-01-01
Thermophotovoltaic cells containing multiple quantum wells have been invented as improved means of conversion of thermal to electrical energy. The semiconductor bandgaps of the quantum wells can be tailored to be narrower than those of prior thermophotovoltaic cells, thereby enabling the cells to convert energy from longer-wavelength photons that dominate the infrared-rich spectra of typical thermal sources with which these cells would be used. Moreover, in comparison with a conventional single-junction thermophotovoltaic cell, a cell containing multiple narrow-bandgap quantum wells according to the invention can convert energy from a wider range of wavelengths. Hence, the invention increases the achievable thermal-to-electrical energy-conversion efficiency. These thermophotovoltaic cells are expected to be especially useful for extracting electrical energy from combustion, waste-heat, and nuclear sources having temperatures in the approximate range from 1,000 to 1,500 C.
Improved wavelength coded optical time domain reflectometry based on the optical switch.
Zhu, Ninghua; Tong, Youwan; Chen, Wei; Wang, Sunlong; Sun, Wenhui; Liu, Jianguo
2014-06-16
This paper presents an improved wavelength coded time-domain reflectometry based on the 2 × 1 optical switch. In this scheme, in order to improve the signal-noise-ratio (SNR) of the beat signal, the improved system used an optical switch to obtain wavelength-stable, low-noise and narrow optical pulses for probe and reference. Experiments were set up to demonstrate a spatial resolution of 2.5m within a range of 70km and obtain the beat signal with line width narrower than 15 MHz within a range of 50 km in fiber break detection. A system for wavelength-division-multiplexing passive optical network (WDM-PON) monitoring was also constructed to detect the fiber break of different channels by tuning the current applied on the gating section of the distributed Bragg reflector (DBR) laser.
Computational model for behavior shaping as an adaptive health intervention strategy.
Berardi, Vincent; Carretero-González, Ricardo; Klepeis, Neil E; Ghanipoor Machiani, Sahar; Jahangiri, Arash; Bellettiere, John; Hovell, Melbourne
2018-03-01
Adaptive behavioral interventions that automatically adjust in real-time to participants' changing behavior, environmental contexts, and individual history are becoming more feasible as the use of real-time sensing technology expands. This development is expected to improve shortcomings associated with traditional behavioral interventions, such as the reliance on imprecise intervention procedures and limited/short-lived effects. JITAI adaptation strategies often lack a theoretical foundation. Increasing the theoretical fidelity of a trial has been shown to increase effectiveness. This research explores the use of shaping, a well-known process from behavioral theory for engendering or maintaining a target behavior, as a JITAI adaptation strategy. A computational model of behavior dynamics and operant conditioning was modified to incorporate the construct of behavior shaping by adding the ability to vary, over time, the range of behaviors that were reinforced when emitted. Digital experiments were performed with this updated model for a range of parameters in order to identify the behavior shaping features that optimally generated target behavior. Narrowing the range of reinforced behaviors continuously in time led to better outcomes compared with a discrete narrowing of the reinforcement window. Rapid narrowing followed by more moderate decreases in window size was more effective in generating target behavior than the inverse scenario. The computational shaping model represents an effective tool for investigating JITAI adaptation strategies. Model parameters must now be translated from the digital domain to real-world experiments so that model findings can be validated.
Deformation across the Pacific-North America plate boundary near San Francisco, California
Prescott, W.H.; Savage, J.C.; Svarc, J.L.; Manaker, D.
2001-01-01
We have detected a narrow zone of compression between the Coast Ranges and the Great Valley, and we have estimated slip rates for the San Andreas, Rodgers Creek, and Green Valley faults just north of San Francisco. These results are based on an analysis of campaign and continuous Global Positioning System (GPS) data collected between 1992 and 2000 in central California. The zone of compression between the Coast Ranges and the Great Valley is 25 km wide. The observations clearly show 3.8??1.5 mm yr-1 of shortening over this narrow zone. The strike slip components are best fit by a model with 20.8??1.9 mm yr-1 slip on the San Andreas fault, 10.3??2.6 mm yr-1 on the Rodgers Creek fault, and 8.1??2.1 mm yr-1 on the Green Valley fault. The Pacific-Sierra Nevada-Great Valley motion totals 39.2??3.8 mm yr-1 across a zone that is 120 km wide (at the latitude of San Francisco). Standard deviations are one ??. The geodetic results suggest a higher than geologic rate for the Green Valley fault. The geodetic results also suggest an inconsistency between geologic estimates of the San Andreas rate and seismologic estimates of the depth of locking on the San Andreas fault. The only convergence observed is in the narrow zone along the border between the Great Valley and the Coast Ranges.
Wei, Haoran; Deng, Shubo; Hu, Bingyin; Chen, Zhenhe; Wang, Bin; Huang, Jun; Yu, Gang
2012-12-01
Cost-effective biomass-derived activated carbons with a high CO(2) adsorption capacity are attractive for carbon capture. Bamboo was found to be a suitable precursor for activated carbon preparation through KOH activation. The bamboo size in the range of 10-200 mesh had little effect on CO(2) adsorption, whereas the KOH/C mass ratio and activation temperature had a significant impact on CO(2) adsorption. The bamboo-derived activated carbon had a high adsorption capacity and excellent selectivity for CO(2) , and also the adsorption process was highly reversible. The adsorbed amount of CO(2) on the granular activated carbon was up to 7.0 mmol g(-1) at 273 K and 1 bar, which was higher than almost all carbon materials. The pore characteristics of activated carbons responsible for high CO(2) adsorption were fully investigated. Based on the analysis of narrow micropore size distribution of several activated carbons prepared under different conditions, a more accurate micropore range contributing to CO(2) adsorption was proposed. The volume of micropores in the range of 0.33-0.82 nm had a good linear relationship with CO(2) adsorption at 273 K and 1 bar, and the narrow micropores of about 0.55 nm produced the major contribution, which could be used to evaluate CO(2) adsorption on activated carbons. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Tessonnier, Thomas; Marcelos, Tiago; Mairani, Andrea; Brons, Stephan; Parodi, Katia
2015-01-01
In the field of radiation therapy, accurate and robust dose calculation is required. For this purpose, precise modeling of the irradiation system and reliable computational platforms are needed. At the Heidelberg Ion Therapy Center (HIT), the beamline has been already modeled in the FLUKA Monte Carlo (MC) code. However, this model was kept confidential for disclosure reasons and was not available for any external team. The main goal of this study was to create efficiently phase space (PS) files for proton and carbon ion beams, for all energies and foci available at HIT. PSs are representing the characteristics of each particle recorded (charge, mass, energy, coordinates, direction cosines, generation) at a certain position along the beam path. In order to achieve this goal, keeping a reasonable data size but maintaining the requested accuracy for the calculation, we developed a new approach of beam PS generation with the MC code FLUKA. The generated PSs were obtained using an infinitely narrow beam and recording the desired quantities after the last element of the beamline, with a discrimination of primaries or secondaries. In this way, a unique PS can be used for each energy to accommodate the different foci by combining the narrow-beam scenario with a random sampling of its theoretical Gaussian beam in vacuum. PS can also reproduce the different patterns from the delivery system, when properly combined with the beam scanning information. MC simulations using PS have been compared to simulations, including the full beamline geometry and have been found in very good agreement for several cases (depth dose distributions, lateral dose profiles), with relative dose differences below 0.5%. This approach has also been compared with measured data of ion beams with different energies and foci, resulting in a very satisfactory agreement. Hence, the proposed approach was able to fulfill the different requirements and has demonstrated its capability for application to clinical treatment fields. It also offers a powerful tool to perform investigations on the contribution of primary and secondary particles produced in the beamline. These PSs are already made available to external teams upon request, to support interpretation of their measurements.
Blood pressure normalization post-jugular venous balloon angioplasty.
Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael
2015-05-01
This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the association between blood pressure deviation and internal jugular veins narrowing, and whether blood pressure normalization affects Patient's clinical outcomes. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poplawski, L; Li, T; Chino, J
Purpose: In brachytherapy, structures surrounding the target have the potential to move between treatments and receive unknown dose. Deformable image registration could overcome challenges through dose accumulation. This study uses two possible deformable dose summation techniques and compares the results to point dose summation currently performed in clinic. Methods: Data for ten patients treated with a Syed template was imported into the MIM software (Cleveland, OH). The deformable registration was applied to structures by masking other image data to a single intensity. The registration flow consisted of the following steps: 1) mask CTs so that each of the structures-of-interest hadmore » one unique intensity; 2) perform applicator — based rigid registration; 3) Perform deformable registration; 4) Refine registration by changing local alignments manually; 5) Repeat steps 1 to 3 until desired structure adequately deformed; 5) Transfer each deformed contours to the first CT. The deformed structure accuracy was determined by a dice similarity coefficient (DSC) comparison with the first fraction. Two dose summation techniques were investigated: a deformation and recalculation on the structure; and a dose deformation and accumulation method. Point doses were used as a comparison value. Results: The Syed deformations have DSC ranging from 0.53 to 0.97 and 0.75 and 0.95 for the bladder and rectum, respectively. For the bladder, contour deformation addition ranged from −34.8% to 0.98% and dose deformation accumulation ranged from −35% to 29.3% difference from clinical calculations. For the rectum, contour deformation addition ranged from −5.2% to 16.9% and the dose deformation accumulation ranged from −29.1% to 15.3% change. Conclusion: Deforming dose for summation leads to different volumetric doses than when dose is recalculated on deformed structures, raising concerns about the accuracy of the deformed dose. DSC alone cannot be used to establish the accuracy of a deformation for brachy dose summation purpose.« less
TH-A-19A-06: Site-Specific Comparison of Analytical and Monte Carlo Based Dose Calculations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuemann, J; Grassberger, C; Paganetti, H
2014-06-15
Purpose: To investigate the impact of complex patient geometries on the capability of analytical dose calculation algorithms to accurately predict dose distributions and to verify currently used uncertainty margins in proton therapy. Methods: Dose distributions predicted by an analytical pencilbeam algorithm were compared with Monte Carlo simulations (MCS) using TOPAS. 79 complete patient treatment plans were investigated for 7 disease sites (liver, prostate, breast, medulloblastoma spine and whole brain, lung and head and neck). A total of 508 individual passively scattered treatment fields were analyzed for field specific properties. Comparisons based on target coverage indices (EUD, D95, D90 and D50)more » were performed. Range differences were estimated for the distal position of the 90% dose level (R90) and the 50% dose level (R50). Two-dimensional distal dose surfaces were calculated and the root mean square differences (RMSD), average range difference (ARD) and average distal dose degradation (ADD), the distance between the distal position of the 80% and 20% dose levels (R80- R20), were analyzed. Results: We found target coverage indices calculated by TOPAS to generally be around 1–2% lower than predicted by the analytical algorithm. Differences in R90 predicted by TOPAS and the planning system can be larger than currently applied range margins in proton therapy for small regions distal to the target volume. We estimate new site-specific range margins (R90) for analytical dose calculations considering total range uncertainties and uncertainties from dose calculation alone based on the RMSD. Our results demonstrate that a reduction of currently used uncertainty margins is feasible for liver, prostate and whole brain fields even without introducing MC dose calculations. Conclusion: Analytical dose calculation algorithms predict dose distributions within clinical limits for more homogeneous patients sites (liver, prostate, whole brain). However, we recommend treatment plan verification using Monte Carlo simulations for patients with complex geometries.« less
SU-F-BRD-05: Robustness of Dose Painting by Numbers in Proton Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Montero, A Barragan; Sterpin, E; Lee, J
Purpose: Proton range uncertainties may cause important dose perturbations within the target volume, especially when steep dose gradients are present as in dose painting. The aim of this study is to assess the robustness against setup and range errors for high heterogeneous dose prescriptions (i.e., dose painting by numbers), delivered by proton pencil beam scanning. Methods: An automatic workflow, based on MATLAB functions, was implemented through scripting in RayStation (RaySearch Laboratories). It performs a gradient-based segmentation of the dose painting volume from 18FDG-PET images (GTVPET), and calculates the dose prescription as a linear function of the FDG-uptake value on eachmore » voxel. The workflow was applied to two patients with head and neck cancer. Robustness against setup and range errors of the conventional PTV margin strategy (prescription dilated by 2.5 mm) versus CTV-based (minimax) robust optimization (2.5 mm setup, 3% range error) was assessed by comparing the prescription with the planned dose for a set of error scenarios. Results: In order to ensure dose coverage above 95% of the prescribed dose in more than 95% of the GTVPET voxels while compensating for the uncertainties, the plans with a PTV generated a high overdose. For the nominal case, up to 35% of the GTVPET received doses 5% beyond prescription. For the worst of the evaluated error scenarios, the volume with 5% overdose increased to 50%. In contrast, for CTV-based plans this 5% overdose was present only in a small fraction of the GTVPET, which ranged from 7% in the nominal case to 15% in the worst of the evaluated scenarios. Conclusion: The use of a PTV leads to non-robust dose distributions with excessive overdose in the painted volume. In contrast, robust optimization yields robust dose distributions with limited overdose. RaySearch Laboratories is sincerely acknowledged for providing us with RayStation treatment planning system and for the support provided.« less
NASA Astrophysics Data System (ADS)
Percoco, Gianluca; Sánchez Salmerón, Antonio J.
2015-09-01
The measurement of millimetre and micro-scale features is performed by high-cost systems based on technologies with narrow working ranges to accurately control the position of the sensors. Photogrammetry would lower the costs of 3D inspection of micro-features and would be applicable to the inspection of non-removable micro parts of large objects too. Unfortunately, the behaviour of photogrammetry is not known when photogrammetry is applied to micro-features. In this paper, the authors address these issues towards the application of digital close-range photogrammetry (DCRP) to the micro-scale, taking into account that in literature there are research papers stating that an angle of view (AOV) around 10° is the lower limit to the application of the traditional pinhole close-range calibration model (CRCM), which is the basis of DCRP. At first a general calibration procedure is introduced, with the aid of an open-source software library, to calibrate narrow AOV cameras with the CRCM. Subsequently the procedure is validated using a reflex camera with a 60 mm macro lens, equipped with extension tubes (20 and 32 mm) achieving magnification of up to 2 times approximately, to verify literature findings with experimental photogrammetric 3D measurements of millimetre-sized objects with micro-features. The limitation experienced by the laser printing technology, used to produce the bi-dimensional pattern on common paper, has been overcome using an accurate pattern manufactured with a photolithographic process. The results of the experimental activity prove that the CRCM is valid for AOVs down to 3.4° and that DCRP results are comparable with the results of existing and more expensive commercial techniques.
Schad, L R; Boesecke, R; Schlegel, W; Hartmann, G H; Sturm, V; Strauss, L G; Lorenz, W J
1987-01-01
A treatment planning system for stereotactic convergent beam irradiation of deeply localized brain tumors is reported. The treatment technique consists of several moving field irradiations in noncoplanar planes at a linear accelerator facility. Using collimated narrow beams, a high concentration of dose within small volumes with a dose gradient of 10-15%/mm was obtained. The dose calculation was based on geometrical information of multiplanar CT or magnetic resonance (MR) imaging data. The patient's head was fixed in a stereotactic localization system, which is usable at CT, MR, and positron emission tomography (PET) installations. Special computer programs for correction of the geometrical MR distortions allowed a precise correlation of the different imaging modalities. The therapist can use combinations of CT, MR, and PET data for defining target volume. For instance, the superior soft tissue contrast of MR coupled with the metabolic features of PET may be a useful addition in the radiation treatment planning process. Furthermore, other features such as calculated dose distribution to critical structures can also be transferred from one set of imaging data to another and can be displayed as three-dimensional shaded structures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsai, YC; Lu, SH; Chen, LH
2016-06-15
Purpose: Patient-specific quality assurance (QA) is necessary to accurately deliver high dose radiation to the target, especially for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT). Unlike previous 2 dimensional (D) array QA devices, Delta{sup 4} can verify the dose delivery in 3D. In this study, the difference between calculated and measured dose distribution was compared with two QA devices (MATRIXX and Delta{sup 4}) to evaluate the delivery accuracy. Methods: Twenty-seven SRS/SBRT plans with VMAT were verified with point-dose and dose-map analysis. We use an ion chamber (A1SL, 0.053cc) for point-dose measurement. For verification of the dose map, themore » differences between the calculated and measured doses were analyzed with a gamma index using MATRIXX and Delta{sup 4} devices. The passing criteria for gamma evaluation were set at 3 mm for distance-to-agreement (DTA) and 3% for dose-difference. A gamma index less than 1 was defined as the verification passing the criteria and satisfying at least 95% of the points. Results: The mean prescribed dose and fraction was 40 ± 14.41 Gy (range: 16–60) and 10 ± 2.35 fractions (range: 1–8), respectively. In point dose analysis, the differences between the calculated and measured doses were all less than 5% (mean: 2.12 ± 1.13%; range: −0.55% to 4.45%). In dose-map analysis, the average passing rates were 99.38 ± 0.96% (range: 95.31–100%) and 100 ± 0.12% (range: 99.5%–100%) for MATRIXX and Delta{sup 4}, respectively. Even using criteria of 2%/2 mm, the passing rate of Delta{sup 4} was still more than 95% (mean: 99 ± 1.08%; range: 95.6%–100%). Conclusion: Both MATRIXX and Delta{sup 4} offer accurate and efficient verification for SRS/SBRT plans. The results measured by MATRIXX and Delta{sup 4} dosimetry systems are similar for SRS/SBRT performed with the VMAT technique.« less
NASA Astrophysics Data System (ADS)
Piroonpan, Thananchai; Katemake, Pichayada; Panritdam, Eagkapong; Pasanphan, Wanvimol
2017-12-01
Chitosan biopolymer is proposed as an alternative EPR dosimeter. Its ability to be EPR dosimeter was studied in comparison with the conventional alanine, sugars (i.e., glucose and sucrose), formate derivatives (i.e., lithium (Li), magnesium (Mg), and calcium (Ca) formate). Ethylene vinyl acetate (EVA) and paraffin were used as binder for the preparation of composite EPR dosimeter. Dose responses of all materials were investigated in a wide dose range of radiation doses, i.e., low-level (0-1 kGy), medium-level (1-10 kGy) and high-level (10-100 kGy). The EPR dosimeter properties were studied under different parameters, i.e., microwave power, materials contents, absorbed doses, storage conditions and post-irradiation effects. Li-formate showed a simple EPR spectrum and exhibited superior radiation response for low-dose range; whereas chitosan and sucrose exhibited linear dose response in all studied dose ranges. The EPR signals of chitosan exhibited similar stability as glucose, Li-formate and alanine at ambient temperature after irradiation as long as a year. All EPR signals of the studied materials were affected post-irradiation temperature and humidity after gamma irradiation. The EPR signal of chitosan exhibited long-term stability and it was not sensitive to high storage temperatures and humidity values after irradiation. Chitosan has a good merit as the alternative bio-based material for a stable EPR dosimeter in a wide range of radiation-absorbed doses.
The Effect of Broadened Ranges of Expectancy on Satisfaction with Performance
1988-08-01
Campbell, D.T. (1971). Hedonic relativism and planning the good society . In M.H. Appley (Ed.), Adaptation-level theory. New York: Academic Press. "€ Brickman...a lower plausible outcome within the expectancy range and see the current outcome as favorable (e.g. This is a good score. It was possible that I...improvement). Persons with narrow ranges of expectancies cannot make these hedonically preferable selective comparisons. Giving Up Too Early and
NASA Astrophysics Data System (ADS)
Augustine, Kurt E.; Walsh, Timothy J.; Beltran, Chris J.; Stoker, Joshua B.; Mundy, Daniel W.; Parry, Mark D.; Bues, Martin; Fatyga, Mirek
2016-04-01
The use of radiation therapy for the treatment of cancer has been carried out clinically since the late 1800's. Early on however, it was discovered that a radiation dose sufficient to destroy cancer cells can also cause severe injury to surrounding healthy tissue. Radiation oncologists continually strive to find the perfect balance between a dose high enough to destroy the cancer and one that avoids damage to healthy organs. Spot scanning or "pencil beam" proton radiotherapy offers another option to improve on this. Unlike traditional photon therapy, proton beams stop in the target tissue, thus better sparing all organs beyond the targeted tumor. In addition, the beams are far narrower and thus can be more precisely "painted" onto the tumor, avoiding exposure to surrounding healthy tissue. To safely treat patients with proton beam radiotherapy, dose verification should be carried out for each plan prior to treatment. Proton dose verification systems are not currently commercially available so the Department of Radiation Oncology at the Mayo Clinic developed its own, called DOSeCHECK, which offers two distinct dose simulation methods: GPU-based Monte Carlo and CPU-based analytical. The three major components of the system include the web-based user interface, the Linux-based dose verification simulation engines, and the supporting services and components. The architecture integrates multiple applications, libraries, platforms, programming languages, and communication protocols and was successfully deployed in time for Mayo Clinic's first proton beam therapy patient. Having a simple, efficient application for dose verification greatly reduces staff workload and provides additional quality assurance, ultimately improving patient safety.
A novel method to correct for pitch and yaw patient setup errors in helical tomotherapy.
Boswell, Sarah A; Jeraj, Robert; Ruchala, Kenneth J; Olivera, Gustavo H; Jaradat, Hazim A; James, Joshua A; Gutierrez, Alonso; Pearson, Dave; Frank, Gary; Mackie, T Rock
2005-06-01
An accurate means of determining and correcting for daily patient setup errors is important to the cancer outcome in radiotherapy. While many tools have been developed to detect setup errors, difficulty may arise in accurately adjusting the patient to account for the rotational error components. A novel, automated method to correct for rotational patient setup errors in helical tomotherapy is proposed for a treatment couch that is restricted to motion along translational axes. In tomotherapy, only a narrow superior/inferior section of the target receives a dose at any instant, thus rotations in the sagittal and coronal planes may be approximately corrected for by very slow continuous couch motion in a direction perpendicular to the scanning direction. Results from proof-of-principle tests indicate that the method improves the accuracy of treatment delivery, especially for long and narrow targets. Rotational corrections about an axis perpendicular to the transverse plane continue to be implemented easily in tomotherapy by adjustment of the initial gantry angle.
SU-F-I-33: Estimating Radiation Dose in Abdominal Fat Quantitative CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, X; Yang, K; Liu, B
Purpose: To compare size-specific dose estimate (SSDE) in abdominal fat quantitative CT with another dose estimate D{sub size,L} that also takes into account scan length. Methods: This study complied with the requirements of the Health Insurance Portability and Accountability Act. At our institution, abdominal fat CT is performed with scan length = 1 cm and CTDI{sub vol} = 4.66 mGy (referenced to body CTDI phantom). A previously developed CT simulation program was used to simulate single rotation axial scans of 6–55 cm diameter water cylinders, and dose integral of the longitudinal dose profile over the central 1 cm length wasmore » used to predict the dose at the center of one-cm scan range. SSDE and D{sub size,L} were assessed for 182 consecutive abdominal fat CT examinations with mean water-equivalent diameter (WED) of 27.8 cm ± 6.0 (range, 17.9 - 42.2 cm). Patient age ranged from 18 to 75 years, and weight ranged from 39 to 163 kg. Results: Mean SSDE was 6.37 mGy ± 1.33 (range, 3.67–8.95 mGy); mean D{sub size,L} was 2.99 mGy ± 0.85 (range, 1.48 - 4.88 mGy); and mean D{sub size,L}/SSDE ratio was 0.46 ± 0.04 (range, 0.40 - 0.55). Conclusion: The conversion factors for size-specific dose estimate in AAPM Report No. 204 were generated using 15 - 30 cm scan lengths. One needs to be cautious in applying SSDE to small length CT scans. For abdominal fat CT, SSDE was 80–150% higher than the dose of 1 cm scan length.« less
Analysis of lomustine drug content in FDA-approved and compounded lomustine capsules.
KuKanich, Butch; Warner, Matt; Hahn, Kevin
2017-02-01
OBJECTIVE To determine the lomustine content (potency) in compounded and FDA-approved lomustine capsules. DESIGN Evaluation study. SAMPLE 2 formulations of lomustine capsules (low dose [7 to 11 mg] and high dose [40 to 48 mg]; 5 capsules/dose/source) from 3 compounders and from 1 manufacturer of FDA-approved capsules. PROCEDURES Lomustine content was measured by use of a validated high-pressure liquid chromatography method. An a priori acceptable range of 90% to 110% of the stated lomustine content was selected on the basis of US Pharmacopeia guidelines. RESULTS The measured amount of lomustine in all compounded capsules was less than the stated content (range, 59% to 95%) and was frequently outside the acceptable range (failure rate, 2/5 to 5/5). Coefficients of variation for lomustine content ranged from 4.1% to 16.7% for compounded low-dose capsules and from 1.1% to 10.8% for compounded high-dose capsules. The measured amount of lomustine in all FDA-approved capsules was slightly above the stated content (range, 104% to 110%) and consistently within the acceptable range. Coefficients of variation for lomustine content were 0.5% for low-dose and 2.3% for high-dose FDA-approved capsules. CONCLUSIONS AND CLINICAL RELEVANCE Compounded lomustine frequently did not contain the stated content of active drug and had a wider range of lomustine content variability than did the FDA-approved product. The sample size was small, and larger studies are needed to confirm these findings; however, we recommend that compounded veterinary formulations of lomustine not be used when appropriate doses can be achieved with FDA-approved capsules or combinations of FDA-approved capsules.
Dondi, Daniele; Merli, Daniele; Pretali, Luca; Fagnoni, Maurizio; Albini, Angelo; Serpone, Nick
2007-11-01
A series of prebiotic mixtures of simple molecules, sources of C, H, N, and O, were examined under conditions that may have prevailed during the Hadean eon (4.6-3.8 billion years), namely an oxygen-free atmosphere and a significant UV radiation flux over a large wavelength range due to the absence of an ozone layer. Mixtures contained a C source (methanol, acetone or other ketones), a N source (ammonia or methylamine), and an O source (water) at various molar ratios of C : H : N : O. When subjected to UV light or heated for periods of 7 to 45 days under an argon atmosphere, they yielded a narrow product distribution of a few principal compounds. Different initial conditions produced different distributions. The nature of the products was ascertained by gas chromatographic-mass spectral analysis (GC-MS). UVC irradiation of an aqueous methanol-ammonia-water prebiotic mixture for 14 days under low UV dose (6 x 10(-2) Einstein) produced methylisourea, hexamethylenetetramine (HMT), methyl-HMT and hydroxy-HMT, whereas under high UV dose (45 days; 1.9 x 10(-1) Einstein) yielded only HMT. By contrast, the prebiotic mixture composed of acetone-ammonia-water produced five principal species with acetamide as the major component; thermally the same mixture produced a different product distribution of four principal species. UVC irradiation of the CH(3)CN-NH(3)-H(2)O prebiotic mixture for 7 days gave mostly trimethyl-s-triazine, whereas in the presence of two metal oxides (TiO(2) or Fe(2)O(3)) also produced some HMT; the thermal process yielded only acetamide.
Evaluation and comparison of absorbed dose for electron beams by LiF and diamond dosimeters
NASA Astrophysics Data System (ADS)
Mosia, G. J.; Chamberlain, A. C.
2007-09-01
The absorbed dose response of LiF and diamond thermoluminescent dosimeters (TLDs), calibrated in 60Co γ-rays, has been determined using the MCNP4B Monte Carlo code system in mono-energetic megavoltage electron beams from 5 to 20 MeV. Evaluation of the dose responses was done against the dose responses of published works by other investigators. Dose responses of both dosimeters were compared to establish if any relation exists between them. The dosimeters were irradiated in a water phantom with the centre of their top surfaces (0.32×0.32 cm 2), placed at dmax perpendicular to the radiation beam on the central axis. For LiF TLD, dose responses ranged from 0.945±0.017 to 0.997±0.011. For the diamond TLD, the dose response ranged from 0.940±0.017 to 1.018±0.011. To correct for dose responses by both dosimeters, energy correction factors were generated from dose response results of both TLDs. For LiF TLD, these correction factors ranged from 1.003 up to 1.058 and for diamond TLD the factors ranged from 0.982 up to 1.064. The results show that diamond TLDs can be used in the place of the well-established LiF TLDs and that Monte Carlo code systems can be used in dose determinations for radiotherapy treatment planning.
Site-specific range uncertainties caused by dose calculation algorithms for proton therapy
NASA Astrophysics Data System (ADS)
Schuemann, J.; Dowdell, S.; Grassberger, C.; Min, C. H.; Paganetti, H.
2014-08-01
The purpose of this study was to assess the possibility of introducing site-specific range margins to replace current generic margins in proton therapy. Further, the goal was to study the potential of reducing margins with current analytical dose calculations methods. For this purpose we investigate the impact of complex patient geometries on the capability of analytical dose calculation algorithms to accurately predict the range of proton fields. Dose distributions predicted by an analytical pencil-beam algorithm were compared with those obtained using Monte Carlo (MC) simulations (TOPAS). A total of 508 passively scattered treatment fields were analyzed for seven disease sites (liver, prostate, breast, medulloblastoma-spine, medulloblastoma-whole brain, lung and head and neck). Voxel-by-voxel comparisons were performed on two-dimensional distal dose surfaces calculated by pencil-beam and MC algorithms to obtain the average range differences and root mean square deviation for each field for the distal position of the 90% dose level (R90) and the 50% dose level (R50). The average dose degradation of the distal falloff region, defined as the distance between the distal position of the 80% and 20% dose levels (R80-R20), was also analyzed. All ranges were calculated in water-equivalent distances. Considering total range uncertainties and uncertainties from dose calculation alone, we were able to deduce site-specific estimations. For liver, prostate and whole brain fields our results demonstrate that a reduction of currently used uncertainty margins is feasible even without introducing MC dose calculations. We recommend range margins of 2.8% + 1.2 mm for liver and prostate treatments and 3.1% + 1.2 mm for whole brain treatments, respectively. On the other hand, current margins seem to be insufficient for some breast, lung and head and neck patients, at least if used generically. If no case specific adjustments are applied, a generic margin of 6.3% + 1.2 mm would be needed for breast, lung and head and neck treatments. We conclude that the currently used generic range uncertainty margins in proton therapy should be redefined site specific and that complex geometries may require a field specific adjustment. Routine verifications of treatment plans using MC simulations are recommended for patients with heterogeneous geometries.
Marchand, Sandrine; Lamarche, Isabelle; Gobin, Patrice; Couet, William
2010-08-01
The aim of this study was to evaluate the effect of colistin methanesulphonate (CMS) dose on CMS and colistin pharmacokinetics in rats. Three rats per group received an intravenous bolus of CMS at a dose of 5, 15, 30, 60 or 120 mg/kg. Arterial blood samples were drawn at 0, 5, 15, 30, 60, 90, 120, 150 and 180 min. CMS and colistin plasma concentrations were determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The pharmacokinetic parameters of CMS and colistin were calculated by non-compartmental analysis. Linear relationships were observed between CMS and colistin AUCs to infinity and CMS doses, as well as between CMS and colistin C(max) and CMS doses. CMS and colistin pharmacokinetics were linear for a range of colistin concentrations covering the range of values encountered and recommended in patients even during treatment with higher doses.
Dose density in adjuvant chemotherapy for breast cancer.
Citron, Marc L
2004-01-01
Dose-dense chemotherapy increases the dose intensity of the regimen by delivering standard-dose chemotherapy with shorter intervals between the cycles. This article discusses the rationale for dose-dense therapy and reviews the results with dose-dense adjuvant regimens in recent clinical trials in breast cancer. The papers for this review covered evidence of a dose-response relation in cancer chemotherapy; the rationale for dose-intense (and specifically dose-dense) therapy; and clinical experience with dose-dense regimens in adjuvant chemotherapy for breast cancer, with particular attention to outcomes and toxicity. Evidence supports maintaining the dose intensity of adjuvant chemotherapy within the conventional dose range. Disease-free and overall survival with combination cyclophosphamide, methotrexate, and fluorouracil are significantly improved when patients receive within 85% of the planned dose. Moderate and high dose cyclophosphamide, doxorubicin, and fluorouracil within the standard range results in greater disease-free and overall survival than the low dose regimen. The sequential addition of paclitaxel after concurrent doxorubicin and cyclophosphamide also significantly improves survival. Disease-free and overall survival with dose-dense sequential or concurrent doxorubicin, cyclophosphamide, and paclitaxel with filgrastim (rhG-CSF; NEUPOGEN) support are significantly greater than with conventional schedules (q21d). The delivered dose intensity of adjuvant chemotherapy within the standard dose range is an important predictor of the clinical outcome. Prospective trials of high-dose chemotherapy have shown no improvement over standard regimens, and toxicity was greater. Dose-dense adjuvant chemotherapy improves the clinical outcomes with doxorubicin-containing regimens. Filgrastim support enables the delivery of dose-dense chemotherapy and reduces the risk of neutropenia and its complications.
A Population Pharmacokinetic Model for 51Cr EDTA to Estimate Renal Function.
Kuan, Isabelle H S; Duffull, Stephen B; Putt, Tracey L; Schollum, John B W; Walker, Robert J; Wright, Daniel F B
2017-06-01
51 Cr EDTA clearance (CL) from plasma is used to estimate glomerular filtration rate (GFR). We propose that current methods for analysing the raw 51 Cr EDTA measurements over-simplifies the disposition of 51 Cr EDTA and therefore could produce biased GFR estimates. The aim of this study was to develop a population pharmacokinetic model for 51 Cr EDTA disposition and to compare model-predicted GFR to other methods of estimating renal function. Data from 40 individuals who received ~7.4 MBq of 51 Cr EDTA, as an intravenous bolus, were available for analysis. Plasma radioactivity (counts/min) was measured from timed collection points at 2, 4, 6 and 24 h after the dose. A population analysis was conducted using NONMEM ® version 7.2. Model-predicted GFR was compared with other methods for estimating renal function using mean prediction error (MPE). A two-compartment pharmacokinetic model with first-order elimination best fit the data. Compared with the model predictions, creatinine CL from 24 h urine data was unbiased. The commonly used 'slope-intercept' method for estimating isotopic GFR was positively biased compared with the model (MPE 15.5 mL/min/1.73 m 2 [95% confidence interval {CI} 8.9-22.2]. The Cockcroft Gault, Modification of Diet in Renal Disease (MDRD) and Chronic Kidney Disease Epidemiology Collaboration (CKD-Epi) equations led to negatively biased GFR estimates (MPE -19.0 [95% CI -25.4 to -12.7], -20.1 [95% CI -27.2 to -13.1] and -16.5 [95% CI -22.2 to -10.1] mL/min/1.73 m 2 , respectively). The biased GFR estimates were most obvious in patients with relatively normal renal function. This may lead to inaccurate dosing in patients who are receiving drugs with a narrow therapeutic range where dosing is adjusted according to GFR estimates (e.g. carboplatin). The study is registered with the Australian New Zealand Clinical Trials Registry (ANZCTR), number: ACTRN 12611000035921.
Defining Nitrogen Kinetics for Air Break in Prebreath
NASA Technical Reports Server (NTRS)
Conkin, Johnny
2010-01-01
Actual tissue nitrogen (N2) kinetics are complex; the uptake and elimination is often approximated with a single half-time compartment in statistical descriptions of denitrogenation [prebreathe(PB)] protocols. Air breaks during PB complicate N2 kinetics. A comparison of symmetrical versus asymmetrical N2 kinetics was performed using the time to onset of hypobaric decompression sickness (DCS) as a surrogate for actual venous N2 tension. METHODS: Published results of 12 tests involving 179 hypobaric exposures in altitude chambers after PB, with and without airbreaks, provide the complex protocols from which to model N2 kinetics. DCS survival time for combined control and airbreaks were described with an accelerated log logistic model where N2 uptake and elimination before, during, and after the airbreak was computed with a simple exponential function or a function that changed half-time depending on ambient N2 partial pressure. P1N2-P2 = (Delta)P defined decompression dose for each altitude exposure, where P2 was the test altitude and P1N2 was computed N2 pressure at the beginning of the altitude exposure. RESULTS: The log likelihood (LL) without decompression dose (null model) was -155.6, and improved (best-fit) to -97.2 when dose was defined with a 240 min half-time for both N2 elimination and uptake during the PB. The description of DCS survival time was less precise with asymmetrical N2 kinetics, for example, LL was -98.9 with 240 min half-time elimination and 120 min half-time uptake. CONCLUSION: The statistical regression described survival time mechanistically linked to symmetrical N2 kinetics during PBs that also included airbreaks. The results are data-specific, and additional data may change the conclusion. The regression is useful to compute additional PB time to compensate for an airbreak in PB within the narrow range of tested conditions.
Herb-drug pharmacokinetic interaction between carica papaya extract and amiodarone in rats.
Rodrigues, Márcio; Alves, Gilberto; Francisco, Joana; Fortuna, Ana; Falcão, Amílcar
2014-01-01
Carica papaya has been traditionally used worldwide in folk medicine to treat a wide range of ailments in humans, including the management of obesity and digestive disorders. However, scientific information about its potential to interact with conventional drugs is lacking. Thus, this work aimed to investigate the interference of a standardized C. papaya extract (GMP certificate) on the systemic exposure to amiodarone (a narrow therapeutic index drug) in rats. In the first pharmacokinetic study, rats were simultaneously co-administered with a single-dose of C. papaya (1230 mg/kg, p.o.) and amiodarone (50 mg/kg, p.o.); in the second study, rats were pre-treated for 14 days with C. papaya (1230 mg/kg/day, p.o.) and received amiodarone (50 mg/kg, p.o.) on the 15th day. Rats of the control groups received the herbal extract vehicle. Blood samples were collected before dosing and at 0.25, 0.5, 1, 2, 4, 6, 8 and 12 h following amiodarone administration; in addition, at 24 h post-dose, blood and tissues (heart, liver, kidneys and lungs) were also harvested. Thereafter, the concentrations of amiodarone and its major metabolite (mono-N-desethylamiodarone) were determined in plasma and tissue samples employing a high-performance liquid chromatography-diode array detection method previously developed and validated. In both studies was observed a delay in attaining the maximum plasma concentrations of amiodarone (tmax) in the rats treated with the extract. Nevertheless, it must be highlighted the marked increase (60-70%) of the extent of amiodarone systemic exposure (as assessed by AUC0-t and AUC0-∞) in the rats pre-treated with C. papaya comparatively with the control (vehicle) group. The results herein found suggest an herb-drug interaction between C. papaya extract and amiodarone, which clearly increase the drug bioavailability. To reliably assess the clinical impact of these findings appropriate human studies should be conducted.
Defining Nitrogen Kinetics for Air Break in Prebreathe
NASA Technical Reports Server (NTRS)
Conkin, Johnny
2009-01-01
Actual tissue nitrogen (N2) kinetics are complex; the uptake and elimination is often approximated with a single half-time compartment in statistical descriptions of denitrogenation [prebreathe (PB)] protocols. Air breaks during PB complicate N2 kinetics. A comparison of symmetrical versus asymmetrical N2 kinetics was performed using the time to onset of hypobaric decompression sickness (DCS) as a surrogate for actual venous N2 tension. Published results of 12 tests involving 179 hypobaric exposures in altitude chambers after PB, with and without air breaks, provide the complex protocols from which to model N2 kinetics. DCS survival time for combined control and air breaks were described with an accelerated log logistic model where N2 uptake and elimination before, during, and after the air break was computed with a simple exponential function or a function that changed half-time depending on ambient N2 partial pressure. P1N2-P2 = delta P defined DCS dose for each altitude exposure, where P2 was the test altitude and P1N2 was computed N2 pressure at the beginning of the altitude exposure. The log likelihood (LL) without DCS dose (null model) was -155.6, and improved (best-fit) to -97.2 when dose was defined with a 240 min half-time for both N2 elimination and uptake during the PB. The description of DCS survival time was less precise with asymmetrical N2 kinetics, for example, LL was -98.9 with 240 min half-time elimination and 120 min half-time uptake. The statistical regression described survival time mechanistically linked to symmetrical N2 kinetics during PBs that also included air breaks. The results are data-specific, and additional data may change the conclusion. The regression is useful to compute additional PB time to compensate for an air break in PB within the narrow range of tested conditions.
Narrow Quasar Absorption Lines and the History of the Universe
NASA Astrophysics Data System (ADS)
Liebscher, Dierck-Ekkehard
In order to get an estimation of the parameters of the cosmological model the statistics of narrow absorption lines in quasar spectra is evaluated. To this end a phenomenological model of the evolution of the corresponding absorbers in density, size, number and dimension is presented and compared with the observed evolution in the spectral density of the lines and their column density seen in the equivalent width. In spite of the wide range of possible models, the Einstein-deSitter model is shown to be unlikely because of the implied fast evolution in mass.
Cavity mode-width spectroscopy with widely tunable ultra narrow laser.
Cygan, Agata; Lisak, Daniel; Morzyński, Piotr; Bober, Marcin; Zawada, Michał; Pazderski, Eugeniusz; Ciuryło, Roman
2013-12-02
We explore a cavity-enhanced spectroscopic technique based on determination of the absorbtion coefficient from direct measurement of spectral width of the mode of the optical cavity filled with absorbing medium. This technique called here the cavity mode-width spectroscopy (CMWS) is complementary to the cavity ring-down spectroscopy (CRDS). While both these techniques use information on interaction time of the light with the cavity to determine absorption coefficient, the CMWS does not require to measure very fast signals at high absorption conditions. Instead the CMWS method require a very narrow line width laser with precise frequency control. As an example a spectral line shape of P7 Q6 O₂ line from the B-band was measured with use of an ultra narrow laser system based on two phase-locked external cavity diode lasers (ECDL) having tunability of ± 20 GHz at wavelength range of 687 to 693 nm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bentefour, El H., E-mail: hassan.bentefour@iba-group.com; Prieels, Damien; Tang, Shikui
Purpose: In-vivo dosimetry and beam range verification in proton therapy could play significant role in proton treatment validation and improvements. In-vivo beam range verification, in particular, could enable new treatment techniques one of which could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. This paper reports validation study of an in-vivo range verification method which can reduce the range uncertainty to submillimeter levels and potentially allow for in-vivo dosimetry. Methods: An anthropomorphic pelvic phantom is used to validate the clinical potential of the time-resolved dose method for range verification inmore » the case of prostrate treatment using range modulated anterior proton beams. The method uses a 3 × 4 matrix of 1 mm diodes mounted in water balloon which are read by an ADC system at 100 kHz. The method is first validated against beam range measurements by dose extinction measurements. The validation is first completed in water phantom and then in pelvic phantom for both open field and treatment field configurations. Later, the beam range results are compared with the water equivalent path length (WEPL) values computed from the treatment planning system XIO. Results: Beam range measurements from both time-resolved dose method and the dose extinction method agree with submillimeter precision in water phantom. For the pelvic phantom, when discarding two of the diodes that show sign of significant range mixing, the two methods agree with ±1 mm. Only a dose of 7 mGy is sufficient to achieve this result. The comparison to the computed WEPL by the treatment planning system (XIO) shows that XIO underestimates the protons beam range. Quantifying the exact XIO range underestimation depends on the strategy used to evaluate the WEPL results. To our best evaluation, XIO underestimates the treatment beam range between a minimum of 1.7% and maximum of 4.1%. Conclusions: Time-resolved dose measurement method satisfies the two basic requirements, WEPL accuracy and minimum dose, necessary for clinical use, thus, its potential for in-vivo protons range verification. Further development is needed, namely, devising a workflow that takes into account the limits imposed by proton range mixing and the susceptibility of the comparison of measured and expected WEPLs to errors on the detector positions. The methods may also be used for in-vivo dosimetry and could benefit various proton therapy treatments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makhnovskii, Yurii A.; Berezhkovskii, Alexander M.; Antipov, Anatoly E.
This paper is devoted to particle transport in a tube formed by alternating wide and narrow sections, in the presence of an external biasing force. The focus is on the effective transport coefficients—mobility and diffusivity, as functions of the biasing force and the geometric parameters of the tube. Dependences of the effective mobility and diffusivity on the tube geometric parameters are known in the limiting cases of no bias and strong bias. The approximations used to obtain these results are inapplicable at intermediate values of the biasing force. To bridge the two limits Brownian dynamics simulations were run to determinemore » the transport coefficients at intermediate values of the force. The simulations were performed for a representative set of tube geometries over a wide range of the biasing force. They revealed that there is a range of the narrow section length, where the force dependence of the mobility has a maximum. In contrast, the diffusivity is a monotonically increasing function of the force. A simple formula is proposed, which reduces to the known dependences of the diffusivity on the tube geometric parameters in both limits of zero and strong bias. At intermediate values of the biasing force, the formula catches the diffusivity dependence on the narrow section length, if the radius of these sections is not too small.« less
Support for the beam focusing hypothesis in the false killer whale.
Kloepper, Laura N; Buck, John R; Smith, Adam B; Supin, Alexander Ya; Gaudette, Jason E; Nachtigall, Paul E
2015-08-01
The odontocete sound production system is complex and composed of tissues, air sacs and a fatty melon. Previous studies suggested that the emitted sonar beam might be actively focused, narrowing depending on target distance. In this study, we further tested this beam focusing hypothesis in a false killer whale. Using three linear arrays of hydrophones, we recorded the same emitted click at 2, 4 and 7 m distance and calculated the beamwidth, intensity, center frequency and bandwidth as recorded on each array at every distance. If the whale did not focus her beam, acoustics predicts the intensity would decay with range as a function of spherical spreading and the angular beamwidth would remain constant. On the contrary, our results show that as the distance from the whale to the array increases, the beamwidth is narrower and the received click intensity is higher than that predicted by a spherical spreading function. Each of these measurements is consistent with the animal focusing her beam on a target at a given range. These results support the hypothesis that the false killer whale is 'focusing' its sonar beam, producing a narrower and more intense signal than that predicted by spherical spreading. © 2015. Published by The Company of Biologists Ltd.
Brinkløv, Signe; Jakobsen, Lasse; Ratcliffe, John M; Kalko, Elisabeth K V; Surlykke, Annemarie
2011-01-01
The directionality of bat echolocation calls defines the width of bats' sonar "view," while call intensity directly influences detection range since adequate sound energy must impinge upon objects to return audible echoes. Both are thus crucial parameters for understanding biosonar signal design. Phyllostomid bats have been classified as low intensity or "whispering bats," but recent data indicate that this designation may be inaccurate. Echolocation beam directionality in phyllostomids has only been measured through electrode brain-stimulation of restrained bats, presumably excluding active beam control via the noseleaf. Here, a 12-microphone array was used to measure echolocation call intensity and beam directionality in the frugivorous phyllostomid, Carollia perspicillata, echolocating in flight. The results showed a considerably narrower beam shape (half-amplitude beam angles of approximately 16° horizontally and 14° vertically) and louder echolocation calls [source levels averaging 99 dB sound pressure level (SPL) root mean square] for C. perspicillata than was found for this species when stationary. This suggests that naturally behaving phyllostomids shape their sound beam to achieve a longer and narrower sonar range than previously thought. C. perspicillata orient and forage in the forest interior and the narrow beam might be adaptive in clutter, by reducing the number and intensity of off-axis echoes.
Determination of gonad doses during robotic stereotactic radiosurgery for various tumor sites
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zorlu, Faruk; Dugel, Gozde; Ozyigit, Gokhan
Purpose: The authors evaluated the absorbed dose received by the gonads during robotic stereotactic radiosurgery (SRS) for the treatment of different tumor localizations. Methods: The authors measured the gonad doses during the treatment of head and neck, thoracic, abdominal, or pelvic tumors in both RANDO phantom and actual patients. The computerized tomography images were transferred to the treatment planning system. The contours of tumor and critical organs were delineated on each slice, and treatment plans were generated. Measurements for gonad doses were taken from the geometric projection of the ovary onto the skin for female patients, and from the scrotalmore » skin for male patients by attaching films and Thermoluminescent dosimeters (TLDs). SRS was delivered with CyberKnife (Accuray Inc., Sunnyvale, CA). Results: The median gonadal doses with TLD and film dosimeter in actual patients were 0.19 Gy (range, 0.035-2.71 Gy) and 0.34 Gy (range, 0.066-3.18 Gy), respectively. In the RANDO phantom, the median ovarian doses with TLD and film dosimeter were 0.08 Gy (range, 0.03-0.159 Gy) and 0.05 Gy (range, 0.015-0.13 Gy), respectively. In the RANDO phantom, the median testicular doses with TLD and film dosimeter were 0.134 Gy (range 0.056-1.97 Gy) and 0.306 Gy (range, 0.065-2.25 Gy). Conclusions: Gonad doses are below sterility threshold in robotic SRS for different tumor localizations. However, particular attention should be given to gonads during robotic SRS for pelvic tumors.« less
Julie Beckstead; Susan E. Meyer; Toby S. Ishizuka; Kelsey M. McEvoy; Craig E. Coleman
2016-01-01
Generalist plant pathogens may have wide host ranges, but many exhibit varying degrees of host specialization, with multiple pathogen races that have narrower host ranges. These races are often genetically distinct, with each race causing highest disease incidence on its host of origin. We examined host specialization in the seed pathogen Pyrenophora...
Chahl, J S
2014-01-20
This paper describes an application for arrays of narrow-field-of-view sensors with parallel optical axes. These devices exhibit some complementary characteristics with respect to conventional perspective projection or angular projection imaging devices. Conventional imaging devices measure rotational egomotion directly by measuring the angular velocity of the projected image. Translational egomotion cannot be measured directly by these devices because the induced image motion depends on the unknown range of the viewed object. On the other hand, a known translational motion generates image velocities which can be used to recover the ranges of objects and hence the three-dimensional (3D) structure of the environment. A new method is presented for computing egomotion and range using the properties of linear arrays of independent narrow-field-of-view optical sensors. An approximate parallel projection can be used to measure translational egomotion in terms of the velocity of the image. On the other hand, a known rotational motion of the paraxial sensor array generates image velocities, which can be used to recover the 3D structure of the environment. Results of tests of an experimental array confirm these properties.
Preoperative single fraction partial breast radiotherapy for early-stage breast cancer.
Palta, Manisha; Yoo, Sua; Adamson, Justus D; Prosnitz, Leonard R; Horton, Janet K
2012-01-01
Several recent series evaluating external beam accelerated partial breast irradiation (PBI) have reported adverse cosmetic outcomes, possibly related to large volumes of normal tissue receiving near-prescription doses. We hypothesized that delivery of external beam PBI in a single fraction to the preoperative tumor volume would be feasible and result in a decreased dose to the uninvolved breast compared with institutional postoperative PBI historical controls. A total of 17 patients with unifocal Stage T1 breast cancer were identified. Contrast-enhanced subtraction magnetic resonance images were loaded into an Eclipse treatment planning system and used to define the target volumes. A "virtual plan" was created using four photon beams in a noncoplanar beam arrangement and optimized to deliver 15 Gy to the planning target volume. The median breast volume was 1,713 cm(3) (range: 1,014-2,140), and the median clinical target volume was 44 cm(3) (range: 26-73). In all cases, 100% of the prescription dose covered 95% of the clinical target volume. The median conformity index was 0.86 (range: 0.70-1.12). The median percentage of the ipsilateral breast volume receiving 100% and 50% of the prescribed dose was 3.8% (range: 2.2-6.9) and 13.3% (range: 7.5-20.8) compared with 18% (range: 3-42) and 53% (range: 24-65) in the institutional historical controls treated with postoperative external beam PBI (p = .002). The median maximum skin dose was 9 Gy. The median dose to 1 and 10 cm(3) of skin was 6.7 and 4.9 Gy. The doses to the heart and ipsilateral lung were negligible. Preoperative PBI resulted in a substantial reduction in ipsilateral breast tissue dose compared with postoperative PBI. The skin dose appeared reasonable, given the small volumes. A prospective Phase I trial evaluating this technique is ongoing. Copyright © 2012 Elsevier Inc. All rights reserved.
Troeller, A; Soehn, M; Yan, D
2012-06-01
Introducing an extended, phenomenological, generalized equivalent uniform dose (eEUD) that incorporates multiple volume-effect parameters for different dose-ranges. The generalized EUD (gEUD) was introduced as an estimate of the EUD that incorporates a single, tissue-specific parameter - the volume-effect-parameter (VEP) 'a'. As a purely phenomenological concept, its radio-biological equivalency to a given inhomogeneous dose distribution is not a priori clear and mechanistic models based on radio-biological parameters are assumed to better resemble the underlying biology. However, for normal organs mechanistic models are hard to derive, since the structural organization of the tissue plays a significant role. Consequently, phenomenological approaches might be especially useful in order to describe dose-response for normal tissues. However, the single parameter used to estimate the gEUD may not suffice in accurately representing more complex biological effects that have been discussed in the literature. For instance, radio-biological parameters and hence the effects of fractionation are known to be dose-range dependent. Therefore, we propose an extended phenomenological eEUD formula that incorporates multiple VEPs accounting for dose-range dependency. The eEUD introduced is a piecewise polynomial expansion of the gEUD formula. In general, it allows for an arbitrary number of VEPs, each valid for a certain dose-range. We proved that the formula fulfills required mathematical and physical criteria such as invertibility of the underlying dose-effect and continuity in dose. Furthermore, it contains the gEUD as a special case, if all VEPs are equal to 'a' from the gEUD model. The eEUD is a concept that expands the gEUD such that it can theoretically represent dose-range dependent effects. Its practicality, however, remains to be shown. As a next step, this will be done by estimating the eEUD from patient data using maximum-likelihood based NTCP modelling in the same way it is commonly done for the gEUD. © 2012 American Association of Physicists in Medicine.
Enhanced tunable narrow-band THz emission from laser-modulated electron beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiang, D.; Stupakov, G.; /SLAC
2009-06-19
We propose and analyze a scheme to generate enhanced narrow-band terahertz (THz) radiation through down-conversion of the frequency of optical lasers using laser-modulated electron beams. In the scheme the electron beam is first energy modulated by two lasers with wave numbers k{sub 1} and k2, respectively. After passing through a dispersion section, the energy modulation is converted to density modulation. Due to the nonlinear conversion process, the beam will have density modulation at wave number k = nk{sub 1} + mk{sub 2}, where n and m are positive or negative integers. By properly choosing the parameters for the lasers andmore » dispersion section, one can generate density modulation at THz frequency in the beam using optical lasers. This density-modulated beam can be used to generate powerful narrow-band THz radiation. Since the THz radiation is in tight synchronization with the lasers, it should provide a high temporal resolution for the optical-pump THz-probe experiments. The central frequency of the THz radiation can be easily tuned by varying the wavelength of the two lasers and the energy chirp of the electron beam. The proposed scheme is in principle able to generate intense narrow-band THz radiation covering the whole THz range and offers a promising way towards the tunable intense narrow-band THz sources.« less
Yoshida, Ken; Yamazaki, Hideya; Takenaka, Tadashi; Kotsuma, Tadayuki; Yoshida, Mineo; Furuya, Seiichi; Tanaka, Eiichi; Uegaki, Tadaaki; Kuriyama, Keiko; Matsumoto, Hisanobu; Yamada, Shigetoshi; Ban, Chiaki
2010-07-01
To investigate the feasibility of our novel image-based high-dose-rate interstitial brachytherapy (HDR-ISBT) for uterine cervical cancer, we evaluated the dose-volume histogram (DVH) according to the recommendations of the Gynecological GEC-ESTRO Working Group for image-based intracavitary brachytherapy (ICBT). Between June 2005 and June 2007, 18 previously untreated cervical cancer patients were enrolled. We implanted magnetic resonance imaging (MRI)-available plastic applicators by our unique ambulatory technique. Total treatment doses were 30-36 Gy (6 Gy per fraction) combined with external beam radiotherapy (EBRT). Treatment plans were created based on planning computed tomography with MRI as a reference. DVHs of the high-risk clinical target volume (HR CTV), intermediate-risk CTV (IR CTV), and the bladder and rectum were calculated. Dose values were biologically normalized to equivalent doses in 2-Gy fractions (EQD(2)). The median D90 (HR CTV) and D90 (IR CTV) per fraction were 6.8 Gy (range, 5.5-7.5) and 5.4 Gy (range, 4.2-6.3), respectively. The median V100 (HR CTV) and V100 (IR CTV) were 98.4% (range, 83-100) and 81.8% (range, 64-93.8), respectively. When the dose of EBRT was added, the median D90 and D100 of HR CTV were 80.6 Gy (range, 65.5-96.6) and 62.4 Gy (range, 49-83.2). The D(2cc) of the bladder was 62 Gy (range, 51.4-89) and of the rectum was 65.9 Gy (range, 48.9-76). Although the targets were advanced and difficult to treat effectively by ICBT, MRI-aided image-based ISBT showed favorable results for CTV and organs at risk compared with previously reported image-based ICBT results. (c) 2010 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Ambrogi, F.; Asilar, E.; Bergauer, T.; Brandstetter, J.; Brondolin, E.; Dragicevic, M.; Erö, J.; Escalante Del Valle, A.; Flechl, M.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Grossmann, J.; Hrubec, J.; Jeitler, M.; König, A.; Krammer, N.; Krätschmer, I.; Liko, D.; Madlener, T.; Mikulec, I.; Pree, E.; Rad, N.; Rohringer, H.; Schieck, J.; Schöfbeck, R.; Spanring, M.; Spitzbart, D.; Taurok, A.; Waltenberger, W.; Wittmann, J.; Wulz, C.-E.; Zarucki, M.; Chekhovsky, V.; Mossolov, V.; Suarez Gonzalez, J.; De Wolf, E. A.; Di Croce, D.; Janssen, X.; Lauwers, J.; Pieters, M.; Van De Klundert, M.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Abu Zeid, S.; Blekman, F.; D'Hondt, J.; De Bruyn, I.; De Clercq, J.; Deroover, K.; Flouris, G.; Lontkovskyi, D.; Lowette, S.; Marchesini, I.; Moortgat, S.; Moreels, L.; Python, Q.; Skovpen, K.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Parijs, I.; Beghin, D.; Bilin, B.; Brun, H.; Clerbaux, B.; De Lentdecker, G.; Delannoy, H.; Dorney, B.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Kalsi, A. K.; Lenzi, T.; Luetic, J.; Seva, T.; Starling, E.; Vander Velde, C.; Vanlaer, P.; Vannerom, D.; Yonamine, R.; Cornelis, T.; Dobur, D.; Fagot, A.; Gul, M.; Khvastunov, I.; Poyraz, D.; Roskas, C.; Trocino, D.; Tytgat, M.; Verbeke, W.; Vermassen, B.; Vit, M.; Zaganidis, N.; Bakhshiansohi, H.; Bondu, O.; Brochet, S.; Bruno, G.; Caputo, C.; Caudron, A.; David, P.; De Visscher, S.; Delaere, C.; Delcourt, M.; Francois, B.; Giammanco, A.; Krintiras, G.; Lemaitre, V.; Magitteri, A.; Mertens, A.; Musich, M.; Piotrzkowski, K.; Quertenmont, L.; Saggio, A.; Vidal Marono, M.; Wertz, S.; Zobec, J.; Aldá Júnior, W. L.; Alves, F. L.; Alves, G. A.; Brito, L.; Correia Silva, G.; Hensel, C.; Moraes, A.; Pol, M. E.; Rebello Teles, P.; Belchior Batista Das Chagas, E.; Carvalho, W.; Chinellato, J.; Coelho, E.; Da Costa, E. M.; Da Silveira, G. G.; De Jesus Damiao, D.; Fonseca De Souza, S.; Malbouisson, H.; Medina Jaime, M.; Melo De Almeida, M.; Mora Herrera, C.; Mundim, L.; Nogima, H.; Sanchez Rosas, L. J.; Santoro, A.; Sznajder, A.; Thiel, M.; Tonelli Manganote, E. J.; Torres Da Silva De Araujo, F.; Vilela Pereira, A.; Ahuja, S.; Bernardes, C. A.; Calligaris, L.; Tomei, T. R. Fernandez Perez; Gregores, E. M.; Mercadante, P. G.; Novaes, S. F.; Padula, Sandra S.; Romero Abad, D.; Ruiz Vargas, J. C.; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Marinov, A.; Misheva, M.; Rodozov, M.; Shopova, M.; Sultanov, G.; Dimitrov, A.; Litov, L.; Pavlov, B.; Petkov, P.; Fang, W.; Gao, X.; Yuan, L.; Ahmad, M.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Chen, Y.; Jiang, C. H.; Leggat, D.; Liao, H.; Liu, Z.; Romeo, F.; Shaheen, S. M.; Spiezia, A.; Tao, J.; Wang, C.; Wang, Z.; Yazgan, E.; Zhang, H.; Zhao, J.; Ban, Y.; Chen, G.; Li, J.; Li, Q.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Wang, Y.; Avila, C.; Cabrera, A.; Carrillo Montoya, C. A.; Chaparro Sierra, L. F.; Florez, C.; González Hernández, C. F.; Segura Delgado, M. A.; Courbon, B.; Godinovic, N.; Lelas, D.; Puljak, I.; Ribeiro Cipriano, P. M.; Sculac, T.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Ferencek, D.; Kadija, K.; Mesic, B.; Starodumov, A.; Susa, T.; Ather, M. W.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Finger, M.; Finger, M.; Carrera Jarrin, E.; Assran, Y.; Elgammal, S.; Mahmoud, M. A.; Bhowmik, S.; Dewanjee, R. K.; Kadastik, M.; Perrini, L.; Raidal, M.; Veelken, C.; Eerola, P.; Kirschenmann, H.; Pekkanen, J.; Voutilainen, M.; Havukainen, J.; Heikkilä, J. K.; Järvinen, T.; Karimäki, V.; Kinnunen, R.; Lampén, T.; Lassila-Perini, K.; Laurila, S.; Lehti, S.; Lindén, T.; Luukka, P.; Mäenpää, T.; Siikonen, H.; Tuominen, E.; Tuominiemi, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Faure, J. L.; Ferri, F.; Ganjour, S.; Ghosh, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Leloup, C.; Locci, E.; Machet, M.; Malcles, J.; Negro, G.; Rander, J.; Rosowsky, A.; Sahin, M. Ö.; Titov, M.; Abdulsalam, A.; Amendola, C.; Antropov, I.; Baffioni, S.; Beaudette, F.; Busson, P.; Cadamuro, L.; Charlot, C.; Granier de Cassagnac, R.; Jo, M.; Kucher, I.; Lisniak, S.; Lobanov, A.; Martin Blanco, J.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Pigard, P.; Salerno, R.; Sauvan, J. B.; Sirois, Y.; Stahl Leiton, A. G.; Yilmaz, Y.; Zabi, A.; Zghiche, A.; Agram, J.-L.; Andrea, J.; Bloch, D.; Brom, J.-M.; Chabert, E. C.; Collard, C.; Conte, E.; Coubez, X.; Drouhin, F.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Jansová, M.; Juillot, P.; Le Bihan, A.-C.; Tonon, N.; Van Hove, P.; Gadrat, S.; Beauceron, S.; Bernet, C.; Boudoul, G.; Chanon, N.; Chierici, R.; Contardo, D.; Depasse, P.; El Mamouni, H.; Fay, J.; Finco, L.; Gascon, S.; Gouzevitch, M.; Grenier, G.; Ille, B.; Lagarde, F.; Laktineh, I. B.; Lattaud, H.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Popov, A.; Sordini, V.; Vander Donckt, M.; Viret, S.; Zhang, S.; Toriashvili, T.; Tsamalaidze, Z.; Autermann, C.; Feld, L.; Kiesel, M. K.; Klein, K.; Lipinski, M.; Preuten, M.; Rauch, M. P.; Schomakers, C.; Schulz, J.; Teroerde, M.; Wittmer, B.; Zhukov, V.; Albert, A.; Duchardt, D.; Endres, M.; Erdmann, M.; Erdweg, S.; Esch, T.; Fischer, R.; Güth, A.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Knutzen, S.; Merschmeyer, M.; Meyer, A.; Millet, P.; Mukherjee, S.; Pook, T.; Radziej, M.; Reithler, H.; Rieger, M.; Scheuch, F.; Teyssier, D.; Thüer, S.; Flügge, G.; Kargoll, B.; Kress, T.; Künsken, A.; Müller, T.; Nehrkorn, A.; Nowack, A.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Arndt, T.; Asawatangtrakuldee, C.; Beernaert, K.; Behnke, O.; Behrens, U.; Bermúdez Martínez, A.; Bin Anuar, A. A.; Borras, K.; Botta, V.; Campbell, A.; Connor, P.; Contreras-Campana, C.; Costanza, F.; Danilov, V.; De Wit, A.; Diez Pardos, C.; Domínguez Damiani, D.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Elwood, A.; Eren, E.; Gallo, E.; Garay Garcia, J.; Geiser, A.; Grados Luyando, J. M.; Grohsjean, A.; Gunnellini, P.; Guthoff, M.; Harb, A.; Hauk, J.; Jung, H.; Kasemann, M.; Keaveney, J.; Kleinwort, C.; Knolle, J.; Korol, I.; Krücker, D.; Lange, W.; Lelek, A.; Lenz, T.; Lipka, K.; Lohmann, W.; Mankel, R.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Meyer, M.; Missiroli, M.; Mittag, G.; Mnich, J.; Mussgiller, A.; Pitzl, D.; Raspereza, A.; Savitskyi, M.; Saxena, P.; Shevchenko, R.; Stefaniuk, N.; Tholen, H.; Van Onsem, G. P.; Walsh, R.; Wen, Y.; Wichmann, K.; Wissing, C.; Zenaiev, O.; Aggleton, R.; Bein, S.; Blobel, V.; Centis Vignali, M.; Dreyer, T.; Garutti, E.; Gonzalez, D.; Haller, J.; Hinzmann, A.; Hoffmann, M.; Karavdina, A.; Kasieczka, G.; Klanner, R.; Kogler, R.; Kovalchuk, N.; Kurz, S.; Kutzner, V.; Lange, J.; Marconi, D.; Multhaup, J.; Niedziela, M.; Nowatschin, D.; Peiffer, T.; Perieanu, A.; Reimers, A.; Scharf, C.; Schleper, P.; Schmidt, A.; Schumann, S.; Schwandt, J.; Sonneveld, J.; Stadie, H.; Steinbrück, G.; Stober, F. M.; Stöver, M.; Troendle, D.; Usai, E.; Vanhoefer, A.; Vormwald, B.; Akbiyik, M.; Barth, C.; Baselga, M.; Baur, S.; Butz, E.; Caspart, R.; Chwalek, T.; Colombo, F.; De Boer, W.; Dierlamm, A.; Faltermann, N.; Freund, B.; Friese, R.; Giffels, M.; Harrendorf, M. A.; Hartmann, F.; Heindl, S. M.; Husemann, U.; Kassel, F.; Kudella, S.; Mildner, H.; Mozer, M. U.; Müller, Th.; Plagge, M.; Quast, G.; Rabbertz, K.; Schröder, M.; Shvetsov, I.; Sieber, G.; Simonis, H. J.; Ulrich, R.; Wayand, S.; Weber, M.; Weiler, T.; Williamson, S.; Wöhrmann, C.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Kyriakis, A.; Loukas, D.; Topsis-Giotis, I.; Karathanasis, G.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Tziaferi, E.; Kousouris, K.; Papakrivopoulos, I.; Evangelou, I.; Foudas, C.; Gianneios, P.; Katsoulis, P.; Kokkas, P.; Mallios, S.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Strologas, J.; Triantis, F. A.; Tsitsonis, D.; Csanad, M.; Filipovic, N.; Pasztor, G.; Surányi, O.; Veres, G. I.; Bencze, G.; Hajdu, C.; Horvath, D.; Hunyadi, Á.; Sikler, F.; Veszpremi, V.; Vesztergombi, G.; Vámi, T. Á.; Beni, N.; Czellar, S.; Karancsi, J.; Makovec, A.; Molnar, J.; Szillasi, Z.; Bartók, M.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Choudhury, S.; Komaragiri, J. R.; Bahinipati, S.; Mal, P.; Mandal, K.; Nayak, A.; Sahoo, D. K.; Swain, S. K.; Bansal, S.; Beri, S. B.; Bhatnagar, V.; Chauhan, S.; Chawla, R.; Dhingra, N.; Gupta, R.; Kaur, A.; Kaur, M.; Kaur, S.; Kumar, R.; Kumari, P.; Lohan, M.; Mehta, A.; Sharma, S.; Singh, J. B.; Walia, G.; Kumar, Ashok; Shah, Aashaq; Bhardwaj, A.; Choudhary, B. C.; Garg, R. B.; Keshri, S.; Kumar, A.; Malhotra, S.; Naimuddin, M.; Ranjan, K.; Sharma, R.; Bhardwaj, R.; Bhattacharya, R.; Bhattacharya, S.; Bhawandeep, U.; Bhowmik, D.; Dey, S.; Dutt, S.; Dutta, S.; Ghosh, S.; Majumdar, N.; Mondal, K.; Mukhopadhyay, S.; Nandan, S.; Purohit, A.; Rout, P. K.; Roy, A.; Roy Chowdhury, S.; Sarkar, S.; Sharan, M.; Singh, B.; Thakur, S.; Behera, P. K.; Chudasama, R.; Dutta, D.; Jha, V.; Kumar, V.; Mohanty, A. K.; Netrakanti, P. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Dugad, S.; Mahakud, B.; Mitra, S.; Mohanty, G. B.; Sur, N.; Sutar, B.; Banerjee, S.; Bhattacharya, S.; Chatterjee, S.; Das, P.; Guchait, M.; Jain, Sa.; Kumar, S.; Maity, M.; Majumder, G.; Mazumdar, K.; Sahoo, N.; Sarkar, T.; Wickramage, N.; Chauhan, S.; Dube, S.; Hegde, V.; Kapoor, A.; Kothekar, K.; Pandey, S.; Rane, A.; Sharma, S.; Chenarani, S.; Eskandari Tadavani, E.; Etesami, S. M.; Khakzad, M.; Mohammadi Najafabadi, M.; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Colaleo, A.; Creanza, D.; Cristella, L.; De Filippis, N.; De Palma, M.; Di Florio, A.; Errico, F.; Fiore, L.; Gelmi, A.; Iaselli, G.; Lezki, S.; Maggi, G.; Maggi, M.; Marangelli, B.; Miniello, G.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Ranieri, A.; Selvaggi, G.; Sharma, A.; Silvestris, L.; Venditti, R.; Verwilligen, P.; Zito, G.; Abbiendi, G.; Battilana, C.; Bonacorsi, D.; Borgonovi, L.; Braibant-Giacomelli, S.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Chhibra, S. S.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Grandi, C.; Guiducci, L.; Iemmi, F.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Albergo, S.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Chatterjee, K.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Latino, G.; Lenzi, P.; Meschini, M.; Paoletti, S.; Russo, L.; Sguazzoni, G.; Strom, D.; Viliani, L.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Primavera, F.; Calvelli, V.; Ferro, F.; Ravera, F.; Robutti, E.; Tosi, S.; Benaglia, A.; Beschi, A.; Brianza, L.; Brivio, F.; Ciriolo, V.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Ghezzi, A.; Govoni, P.; Malberti, M.; Malvezzi, S.; Manzoni, R. A.; Menasce, D.; Moroni, L.; Paganoni, M.; Pauwels, K.; Pedrini, D.; Pigazzini, S.; Ragazzi, S.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; Di Guida, S.; Fabozzi, F.; Fienga, F.; Galati, G.; Iorio, A. O. M.; Khan, W. A.; Lista, L.; Meola, S.; Paolucci, P.; Sciacca, C.; Thyssen, F.; Voevodina, E.; Azzi, P.; Bacchetta, N.; Benato, L.; Bisello, D.; Boletti, A.; Carlin, R.; Carvalho Antunes De Oliveira, A.; Checchia, P.; De Castro Manzano, P.; Dorigo, T.; Dosselli, U.; Gasparini, F.; Gasparini, U.; Gozzelino, A.; Lacaprara, S.; Margoni, M.; Meneguzzo, A. T.; Pozzobon, N.; Ronchese, P.; Rossin, R.; Simonetto, F.; Tiko, A.; Torassa, E.; Zanetti, M.; Zotto, P.; Zumerle, G.; Braghieri, A.; Magnani, A.; Montagna, P.; Ratti, S. P.; Re, V.; Ressegotti, M.; Riccardi, C.; Salvini, P.; Vai, I.; Vitulo, P.; Alunni Solestizi, L.; Biasini, M.; Bilei, G. M.; Cecchi, C.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Leonardi, R.; Manoni, E.; Mantovani, G.; Mariani, V.; Menichelli, M.; Rossi, A.; Santocchia, A.; Spiga, D.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Bianchini, L.; Boccali, T.; Borrello, L.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Fedi, G.; Giannini, L.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Manca, E.; Mandorli, G.; Messineo, A.; Palla, F.; Rizzi, A.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Barone, L.; Cavallari, F.; Cipriani, M.; Daci, N.; Del Re, D.; Di Marco, E.; Diemoz, M.; Gelli, S.; Longo, E.; Marzocchi, B.; Meridiani, P.; Organtini, G.; Pandolfi, F.; Paramatti, R.; Preiato, F.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bartosik, N.; Bellan, R.; Biino, C.; Cartiglia, N.; Castello, R.; Cenna, F.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Kiani, B.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Monteil, E.; Monteno, M.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Romero, A.; Ruspa, M.; Sacchi, R.; Shchelina, K.; Sola, V.; Solano, A.; Staiano, A.; Belforte, S.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; Zanetti, A.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Lee, J.; Lee, S.; Lee, S. W.; Moon, C. S.; Oh, Y. D.; Sekmen, S.; Son, D. C.; Yang, Y. C.; Kim, H.; Moon, D. H.; Oh, G.; Brochero Cifuentes, J. A.; Goh, J.; Kim, T. J.; Cho, S.; Choi, S.; Go, Y.; Gyun, D.; Ha, S.; Hong, B.; Jo, Y.; Kim, Y.; Lee, K.; Lee, K. S.; Lee, S.; Lim, J.; Park, S. K.; Roh, Y.; Almond, J.; Kim, J.; Kim, J. S.; Lee, H.; Lee, K.; Nam, K.; Oh, S. B.; Radburn-Smith, B. C.; Seo, S. h.; Yang, U. K.; Yoo, H. D.; Yu, G. B.; Kim, H.; Kim, J. H.; Lee, J. S. H.; Park, I. C.; Choi, Y.; Hwang, C.; Lee, J.; Yu, I.; Dudenas, V.; Juodagalvis, A.; Vaitkus, J.; Ahmed, I.; Ibrahim, Z. A.; Md Ali, M. A. B.; Mohamad Idris, F.; Wan Abdullah, W. A. T.; Yusli, M. N.; Zolkapli, Z.; Reyes-Almanza, R.; Ramirez-Sanchez, G.; Duran-Osuna, M. C.; Castilla-Valdez, H.; De La Cruz-Burelo, E.; Heredia-De La Cruz, I.; Rabadan-Trejo, R. I.; Lopez-Fernandez, R.; Mejia Guisao, J.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Oropeza Barrera, C.; Vazquez Valencia, F.; Eysermans, J.; Pedraza, I.; Salazar Ibarguen, H. A.; Uribe Estrada, C.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Saddique, A.; Shah, M. A.; Shoaib, M.; Waqas, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Szleper, M.; Traczyk, P.; Zalewski, P.; Bunkowski, K.; Byszuk, A.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Misiura, M.; Olszewski, M.; Pyskir, A.; Walczak, M.; Bargassa, P.; Beirão Da Cruz E Silva, C.; Di Francesco, A.; Faccioli, P.; Galinhas, B.; Gallinaro, M.; Hollar, J.; Leonardo, N.; Lloret Iglesias, L.; Nemallapudi, M. V.; Seixas, J.; Strong, G.; Toldaiev, O.; Vadruccio, D.; Varela, J.; Afanasiev, S.; Bunin, P.; Gavrilenko, M.; Golutvin, I.; Gorbunov, I.; Kamenev, A.; Karjavin, V.; Lanev, A.; Malakhov, A.; Matveev, V.; Moisenz, P.; Palichik, V.; Perelygin, V.; Shmatov, S.; Shulha, S.; Skatchkov, N.; Smirnov, V.; Voytishin, N.; Zarubin, A.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Levchenko, P.; Murzin, V.; Oreshkin, V.; Smirnov, I.; Sosnov, D.; Sulimov, V.; Uvarov, L.; Vavilov, S.; Vorobyev, A.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Karneyeu, A.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Spiridonov, A.; Stepennov, A.; Stolin, V.; Toms, M.; Vlasov, E.; Zhokin, A.; Aushev, T.; Bylinkin, A.; Chistov, R.; Danilov, M.; Parygin, P.; Philippov, D.; Polikarpov, S.; Tarkovskii, E.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Rusakov, S. V.; Terkulov, A.; Baskakov, A.; Belyaev, A.; Boos, E.; Dubinin, M.; Dudko, L.; Ershov, A.; Gribushin, A.; Klyukhin, V.; Kodolova, O.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Snigirev, A.; Blinov, V.; Shtol, D.; Skovpen, Y.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Elumakhov, D.; Godizov, A.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Mandrik, P.; Petrov, V.; Ryutin, R.; Sobol, A.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Babaev, A.; Adzic, P.; Cirkovic, P.; Devetak, D.; Dordevic, M.; Milosevic, J.; Alcaraz Maestre, J.; Bachiller, I.; Barrio Luna, M.; Cerrada, M.; Colino, N.; De La Cruz, B.; Delgado Peris, A.; Fernandez Bedoya, C.; Fernández Ramos, J. P.; Flix, J.; Fouz, M. C.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Moran, D.; Pérez-Calero Yzquierdo, A.; Puerta Pelayo, J.; Redondo, I.; Romero, L.; Soares, M. S.; Triossi, A.; Álvarez Fernández, A.; Albajar, C.; de Trocóniz, J. F.; Cuevas, J.; Erice, C.; Fernandez Menendez, J.; Folgueras, S.; Gonzalez Caballero, I.; González Fernández, J. R.; Palencia Cortezon, E.; Sanchez Cruz, S.; Vischia, P.; Vizan Garcia, J. M.; Cabrillo, I. J.; Calderon, A.; Chazin Quero, B.; Duarte Campderros, J.; Fernandez, M.; Fernández Manteca, P. J.; Garcia-Ferrero, J.; García Alonso, A.; Gomez, G.; Lopez Virto, A.; Marco, J.; Martinez Rivero, C.; Martinez Ruiz del Arbol, P.; Matorras, F.; Piedra Gomez, J.; Prieels, C.; Rodrigo, T.; Ruiz-Jimeno, A.; Scodellaro, L.; Trevisani, N.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Akgun, B.; Auffray, E.; Baillon, P.; Ball, A. H.; Barney, D.; Bendavid, J.; Bianco, M.; Bocci, A.; Botta, C.; Camporesi, T.; Cepeda, M.; Cerminara, G.; Chapon, E.; Chen, Y.; d'Enterria, D.; Dabrowski, A.; Daponte, V.; David, A.; De Gruttola, M.; De Roeck, A.; Deelen, N.; Dobson, M.; du Pree, T.; Dünser, M.; Dupont, N.; Elliott-Peisert, A.; Everaerts, P.; Fallavollita, F.; Franzoni, G.; Fulcher, J.; Funk, W.; Gigi, D.; Gilbert, A.; Gill, K.; Glege, F.; Gulhan, D.; Hegeman, J.; Innocente, V.; Jafari, A.; Janot, P.; Karacheban, O.; Kieseler, J.; Knünz, V.; Kornmayer, A.; Krammer, M.; Lange, C.; Lecoq, P.; Lourenço, C.; Lucchini, M. T.; Malgeri, L.; Mannelli, M.; Martelli, A.; Meijers, F.; Merlin, J. A.; Mersi, S.; Meschi, E.; Milenovic, P.; Moortgat, F.; Mulders, M.; Neugebauer, H.; Ngadiuba, J.; Orfanelli, S.; Orsini, L.; Pantaleo, F.; Pape, L.; Perez, E.; Peruzzi, M.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Pierini, M.; Pitters, F. M.; Rabady, D.; Racz, A.; Reis, T.; Rolandi, G.; Rovere, M.; Sakulin, H.; Schäfer, C.; Schwick, C.; Seidel, M.; Selvaggi, M.; Sharma, A.; Silva, P.; Sphicas, P.; Stakia, A.; Steggemann, J.; Stoye, M.; Tosi, M.; Treille, D.; Tsirou, A.; Veckalns, V.; Verweij, M.; Zeuner, W. D.; Bertl, W.; Caminada, L.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Rohe, T.; Wiederkehr, S. A.; Backhaus, M.; Bäni, L.; Berger, P.; Casal, B.; Chernyavskaya, N.; Dissertori, G.; Dittmar, M.; Donegà, M.; Dorfer, C.; Grab, C.; Heidegger, C.; Hits, D.; Hoss, J.; Klijnsma, T.; Lustermann, W.; Marionneau, M.; Meinhard, M. T.; Meister, D.; Micheli, F.; Musella, P.; Nessi-Tedaldi, F.; Pata, J.; Pauss, F.; Perrin, G.; Perrozzi, L.; Quittnat, M.; Reichmann, M.; Ruini, D.; Sanz Becerra, D. A.; Schönenberger, M.; Shchutska, L.; Tavolaro, V. R.; Theofilatos, K.; Vesterbacka Olsson, M. L.; Wallny, R.; Zhu, D. H.; Aarrestad, T. K.; Amsler, C.; Brzhechko, D.; Canelli, M. F.; De Cosa, A.; Del Burgo, R.; Donato, S.; Galloni, C.; Hreus, T.; Kilminster, B.; Neutelings, I.; Pinna, D.; Rauco, G.; Robmann, P.; Salerno, D.; Schweiger, K.; Seitz, C.; Takahashi, Y.; Zucchetta, A.; Candelise, V.; Chang, Y. H.; Cheng, K. y.; Doan, T. H.; Jain, Sh.; Khurana, R.; Kuo, C. M.; Lin, W.; Pozdnyakov, A.; Yu, S. S.; Kumar, Arun; Chang, P.; Chao, Y.; Chen, K. F.; Chen, P. H.; Fiori, F.; Hou, W.-S.; Hsiung, Y.; Liu, Y. F.; Lu, R.-S.; Paganis, E.; Psallidas, A.; Steen, A.; Tsai, J. f.; Asavapibhop, B.; Kovitanggoon, K.; Singh, G.; Srimanobhas, N.; Bat, A.; Boran, F.; Cerci, S.; Damarseckin, S.; Demiroglu, Z. S.; Dozen, C.; Dumanoglu, I.; Girgis, S.; Gokbulut, G.; Guler, Y.; Hos, I.; Kangal, E. E.; Kara, O.; Kiminsu, U.; Oglakci, M.; Onengut, G.; Ozdemir, K.; Sunar Cerci, D.; Tali, B.; Tok, U. G.; Topakli, H.; Turkcapar, S.; Zorbakir, I. S.; Zorbilmez, C.; Karapinar, G.; Ocalan, K.; Yalvac, M.; Zeyrek, M.; Atakisi, I. O.; Gülmez, E.; Kaya, M.; Kaya, O.; Tekten, S.; Yetkin, E. A.; Agaras, M. N.; Atay, S.; Cakir, A.; Cankocak, K.; Komurcu, Y.; Grynyov, B.; Levchuk, L.; Ball, F.; Beck, L.; Brooke, J. J.; Burns, D.; Clement, E.; Cussans, D.; Davignon, O.; Flacher, H.; Goldstein, J.; Heath, G. P.; Heath, H. F.; Kreczko, L.; Newbold, D. M.; Paramesvaran, S.; Sakuma, T.; Seif El Nasr-storey, S.; Smith, D.; Smith, V. J.; Bell, K. W.; Belyaev, A.; Brew, C.; Brown, R. M.; Cieri, D.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Linacre, J.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Womersley, W. J.; Auzinger, G.; Bainbridge, R.; Bloch, P.; Borg, J.; Breeze, S.; Buchmuller, O.; Bundock, A.; Casasso, S.; Colling, D.; Corpe, L.; Dauncey, P.; Davies, G.; Della Negra, M.; Di Maria, R.; Haddad, Y.; Hall, G.; Iles, G.; James, T.; Komm, M.; Lane, R.; Laner, C.; Lyons, L.; Magnan, A.-M.; Malik, S.; Mastrolorenzo, L.; Matsushita, T.; Nash, J.; Nikitenko, A.; Palladino, V.; Pesaresi, M.; Richards, A.; Rose, A.; Scott, E.; Seez, C.; Shtipliyski, A.; Strebler, T.; Summers, S.; Tapper, A.; Uchida, K.; Vazquez Acosta, M.; Virdee, T.; Wardle, N.; Winterbottom, D.; Wright, J.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Morton, A.; Reid, I. D.; Teodorescu, L.; Zahid, S.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Smith, C.; Bartek, R.; Dominguez, A.; Buccilli, A.; Cooper, S. I.; Henderson, C.; Rumerio, P.; West, C.; Arcaro, D.; Avetisyan, A.; Bose, T.; Gastler, D.; Rankin, D.; Richardson, C.; Rohlf, J.; Sulak, L.; Zou, D.; Benelli, G.; Cutts, D.; Hadley, M.; Hakala, J.; Heintz, U.; Hogan, J. M.; Kwok, K. H. M.; Laird, E.; Landsberg, G.; Lee, J.; Mao, Z.; Morrison, T.; Narain, M.; Pazzini, J.; Piperov, S.; Sagir, S.; Syarif, R.; Yu, D.; Band, R.; Brainerd, C.; Breedon, R.; Burns, D.; Calderon De La Barca Sanchez, M.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Flores, C.; Funk, G.; Ko, W.; Lander, R.; Mclean, C.; Mulhearn, M.; Pellett, D.; Pilot, J.; Shalhout, S.; Shi, M.; Smith, J.; Stolp, D.; Taylor, D.; Tos, K.; Tripathi, M.; Wang, Z.; Zhang, F.; Bachtis, M.; Bravo, C.; Cousins, R.; Dasgupta, A.; Florent, A.; Hauser, J.; Ignatenko, M.; Mccoll, N.; Regnard, S.; Saltzberg, D.; Schnaible, C.; Valuev, V.; Bouvier, E.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Ghiasi Shirazi, S. M. A.; Hanson, G.; Karapostoli, G.; Kennedy, E.; Lacroix, F.; Long, O. R.; Olmedo Negrete, M.; Paneva, M. I.; Si, W.; Wang, L.; Wei, H.; Wimpenny, S.; Yates, B. R.; Branson, J. G.; Cittolin, S.; Derdzinski, M.; Gerosa, R.; Gilbert, D.; Hashemi, B.; Holzner, A.; Klein, D.; Kole, G.; Krutelyov, V.; Letts, J.; Masciovecchio, M.; Olivito, D.; Padhi, S.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Vartak, A.; Wasserbaech, S.; Wood, J.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Amin, N.; Bhandari, R.; Bradmiller-Feld, J.; Campagnari, C.; Citron, M.; Dishaw, A.; Dutta, V.; Franco Sevilla, M.; Gouskos, L.; Heller, R.; Incandela, J.; Ovcharova, A.; Qu, H.; Richman, J.; Stuart, D.; Suarez, I.; Yoo, J.; Anderson, D.; Bornheim, A.; Bunn, J.; Lawhorn, J. M.; Newman, H. B.; Nguyen, T. Q.; Pena, C.; Spiropulu, M.; Vlimant, J. R.; Wilkinson, R.; Xie, S.; Zhang, Z.; Zhu, R. Y.; Andrews, M. B.; Ferguson, T.; Mudholkar, T.; Paulini, M.; Russ, J.; Sun, M.; Vogel, H.; Vorobiev, I.; Weinberg, M.; Cumalat, J. P.; Ford, W. T.; Jensen, F.; Johnson, A.; Krohn, M.; Leontsinis, S.; MacDonald, E.; Mulholland, T.; Stenson, K.; Ulmer, K. A.; Wagner, S. R.; Alexander, J.; Chaves, J.; Cheng, Y.; Chu, J.; Datta, A.; Mcdermott, K.; Mirman, N.; Patterson, J. R.; Quach, D.; Rinkevicius, A.; Ryd, A.; Skinnari, L.; Soffi, L.; Tan, S. M.; Tao, Z.; Thom, J.; Tucker, J.; Wittich, P.; Zientek, M.; Abdullin, S.; Albrow, M.; Alyari, M.; Apollinari, G.; Apresyan, A.; Apyan, A.; Banerjee, S.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Canepa, A.; Cerati, G. B.; Cheung, H. W. K.; Chlebana, F.; Cremonesi, M.; Duarte, J.; Elvira, V. D.; Freeman, J.; Gecse, Z.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Hanlon, J.; Harris, R. M.; Hasegawa, S.; Hirschauer, J.; Hu, Z.; Jayatilaka, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Klima, B.; Kortelainen, M. J.; Kreis, B.; Lammel, S.; Lincoln, D.; Lipton, R.; Liu, M.; Liu, T.; Lopes De Sá, R.; Lykken, J.; Maeshima, K.; Magini, N.; Marraffino, J. M.; Mason, D.; McBride, P.; Merkel, P.; Mrenna, S.; Nahn, S.; O'Dell, V.; Pedro, K.; Prokofyev, O.; Rakness, G.; Ristori, L.; Savoy-Navarro, A.; Schneider, B.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Stoynev, S.; Strait, J.; Strobbe, N.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vernieri, C.; Verzocchi, M.; Vidal, R.; Wang, M.; Weber, H. A.; Whitbeck, A.; Wu, W.; Acosta, D.; Avery, P.; Bortignon, P.; Bourilkov, D.; Brinkerhoff, A.; Carnes, A.; Carver, M.; Curry, D.; Field, R. D.; Furic, I. K.; Gleyzer, S. V.; Joshi, B. M.; Konigsberg, J.; Korytov, A.; Kotov, K.; Ma, P.; Matchev, K.; Mei, H.; Mitselmakher, G.; Shi, K.; Sperka, D.; Terentyev, N.; Thomas, L.; Wang, J.; Wang, S.; Yelton, J.; Joshi, Y. R.; Linn, S.; Markowitz, P.; Rodriguez, J. L.; Ackert, A.; Adams, T.; Askew, A.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Kolberg, T.; Martinez, G.; Perry, T.; Prosper, H.; Saha, A.; Santra, A.; Sharma, V.; Yohay, R.; Baarmand, M. M.; Bhopatkar, V.; Colafranceschi, S.; Hohlmann, M.; Noonan, D.; Roy, T.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Cavanaugh, R.; Chen, X.; Dittmer, S.; Evdokimov, O.; Gerber, C. E.; Hangal, D. A.; Hofman, D. J.; Jung, K.; Kamin, J.; Sandoval Gonzalez, I. D.; Tonjes, M. B.; Varelas, N.; Wang, H.; Wu, Z.; Zhang, J.; Bilki, B.; Clarida, W.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Snyder, C.; Tiras, E.; Wetzel, J.; Yi, K.; Blumenfeld, B.; Cocoros, A.; Eminizer, N.; Fehling, D.; Feng, L.; Gritsan, A. V.; Hung, W. T.; Maksimovic, P.; Roskes, J.; Sarica, U.; Swartz, M.; Xiao, M.; You, C.; Al-bataineh, A.; Baringer, P.; Bean, A.; Boren, S.; Bowen, J.; Castle, J.; Khalil, S.; Kropivnitskaya, A.; Majumder, D.; Mcbrayer, W.; Murray, M.; Rogan, C.; Royon, C.; Sanders, S.; Schmitz, E.; Tapia Takaki, J. D.; Wang, Q.; Ivanov, A.; Kaadze, K.; Maravin, Y.; Modak, A.; Mohammadi, A.; Saini, L. K.; Skhirtladze, N.; Rebassoo, F.; Wright, D.; Baden, A.; Baron, O.; Belloni, A.; Eno, S. C.; Feng, Y.; Ferraioli, C.; Hadley, N. J.; Jabeen, S.; Jeng, G. Y.; Kellogg, R. G.; Kunkle, J.; Mignerey, A. C.; Ricci-Tam, F.; Shin, Y. H.; Skuja, A.; Tonwar, S. C.; Abercrombie, D.; Allen, B.; Azzolini, V.; Barbieri, R.; Baty, A.; Bauer, G.; Bi, R.; Brandt, S.; Busza, W.; Cali, I. A.; D'Alfonso, M.; Demiragli, Z.; Gomez Ceballos, G.; Goncharov, M.; Harris, P.; Hsu, D.; Hu, M.; Iiyama, Y.; Innocenti, G. M.; Klute, M.; Kovalskyi, D.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Maier, B.; Marini, A. C.; Mcginn, C.; Mironov, C.; Narayanan, S.; Niu, X.; Paus, C.; Roland, C.; Roland, G.; Stephans, G. S. F.; Sumorok, K.; Tatar, K.; Velicanu, D.; Wang, J.; Wang, T. W.; Wyslouch, B.; Zhaozhong, S.; Benvenuti, A. C.; Chatterjee, R. M.; Evans, A.; Hansen, P.; Kalafut, S.; Kubota, Y.; Lesko, Z.; Mans, J.; Nourbakhsh, S.; Ruckstuhl, N.; Rusack, R.; Turkewitz, J.; Wadud, M. A.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bloom, K.; Claes, D. R.; Fangmeier, C.; Golf, F.; Gonzalez Suarez, R.; Kamalieddin, R.; Kravchenko, I.; Monroy, J.; Siado, J. E.; Snow, G. R.; Stieger, B.; Godshalk, A.; Harrington, C.; Iashvili, I.; Nguyen, D.; Parker, A.; Rappoccio, S.; Roozbahani, B.; Alverson, G.; Barberis, E.; Freer, C.; Hortiangtham, A.; Massironi, A.; Morse, D. M.; Orimoto, T.; Teixeira De Lima, R.; Wamorkar, T.; Wang, B.; Wisecarver, A.; Wood, D.; Bhattacharya, S.; Charaf, O.; Hahn, K. A.; Mucia, N.; Odell, N.; Schmitt, M. H.; Sung, K.; Trovato, M.; Velasco, M.; Bucci, R.; Dev, N.; Hildreth, M.; Hurtado Anampa, K.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Li, W.; Loukas, N.; Marinelli, N.; Meng, F.; Mueller, C.; Musienko, Y.; Planer, M.; Reinsvold, A.; Ruchti, R.; Siddireddy, P.; Smith, G.; Taroni, S.; Wayne, M.; Wightman, A.; Wolf, M.; Woodard, A.; Alimena, J.; Antonelli, L.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Francis, B.; Hart, A.; Hill, C.; Ji, W.; Ling, T. Y.; Luo, W.; Winer, B. L.; Wulsin, H. W.; Cooperstein, S.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Higginbotham, S.; Kalogeropoulos, A.; Lange, D.; Luo, J.; Marlow, D.; Mei, K.; Ojalvo, I.; Olsen, J.; Palmer, C.; Piroué, P.; Salfeld-Nebgen, J.; Stickland, D.; Tully, C.; Malik, S.; Norberg, S.; Barker, A.; Barnes, V. E.; Das, S.; Gutay, L.; Jones, M.; Jung, A. W.; Khatiwada, A.; Miller, D. H.; Neumeister, N.; Peng, C. C.; Qiu, H.; Schulte, J. F.; Sun, J.; Wang, F.; Xiao, R.; Xie, W.; Cheng, T.; Dolen, J.; Parashar, N.; Chen, Z.; Ecklund, K. M.; Freed, S.; Geurts, F. J. M.; Guilbaud, M.; Kilpatrick, M.; Li, W.; Michlin, B.; Padley, B. P.; Roberts, J.; Rorie, J.; Shi, W.; Tu, Z.; Zabel, J.; Zhang, A.; Bodek, A.; de Barbaro, P.; Demina, R.; Duh, Y. t.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Han, J.; Hindrichs, O.; Khukhunaishvili, A.; Lo, K. H.; Tan, P.; Verzetti, M.; Ciesielski, R.; Goulianos, K.; Mesropian, C.; Agapitos, A.; Chou, J. P.; Gershtein, Y.; Gómez Espinosa, T. A.; Halkiadakis, E.; Heindl, M.; Hughes, E.; Kaplan, S.; Kunnawalkam Elayavalli, R.; Kyriacou, S.; Lath, A.; Montalvo, R.; Nash, K.; Osherson, M.; Saka, H.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Delannoy, A. G.; Heideman, J.; Riley, G.; Rose, K.; Spanier, S.; Thapa, K.; Bouhali, O.; Castaneda Hernandez, A.; Celik, A.; Dalchenko, M.; De Mattia, M.; Delgado, A.; Dildick, S.; Eusebi, R.; Gilmore, J.; Huang, T.; Kamon, T.; Mueller, R.; Pakhotin, Y.; Patel, R.; Perloff, A.; Perniè, L.; Rathjens, D.; Safonov, A.; Tatarinov, A.; Akchurin, N.; Damgov, J.; De Guio, F.; Dudero, P. R.; Faulkner, J.; Gurpinar, E.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Mengke, T.; Muthumuni, S.; Peltola, T.; Undleeb, S.; Volobouev, I.; Wang, Z.; Greene, S.; Gurrola, A.; Janjam, R.; Johns, W.; Maguire, C.; Melo, A.; Ni, H.; Padeken, K.; Ruiz Alvarez, J. D.; Sheldon, P.; Tuo, S.; Velkovska, J.; Xu, Q.; Arenton, M. W.; Barria, P.; Cox, B.; Hirosky, R.; Joyce, M.; Ledovskoy, A.; Li, H.; Neu, C.; Sinthuprasith, T.; Wang, Y.; Wolfe, E.; Xia, F.; Harr, R.; Karchin, P. E.; Poudyal, N.; Sturdy, J.; Thapa, P.; Zaleski, S.; Brodski, M.; Buchanan, J.; Caillol, C.; Carlsmith, D.; Dasu, S.; Dodd, L.; Duric, S.; Gomber, B.; Grothe, M.; Herndon, M.; Hervé, A.; Hussain, U.; Klabbers, P.; Lanaro, A.; Levine, A.; Long, K.; Loveless, R.; Rekovic, V.; Ruggles, T.; Savin, A.; Smith, N.; Smith, W. H.; Woods, N.; CMS Collaboration
2018-05-01
A search for narrow resonances decaying to bottom quark-antiquark pairs is presented, using a data sample of proton-proton collisions at √{s }=8 TeV corresponding to an integrated luminosity of 19.7 fb-1 . The search is extended to masses lower than those reached in typical searches for resonances decaying into jet pairs at the LHC, by taking advantage of triggers that identify jets originating from bottom quarks. No significant excess of events is observed above the background predictions. Limits are set on the product of cross section and branching fraction to bottom quarks for spin 0, 1, and 2 resonances in the mass range of 325-1200 GeV. These results improve on the limits for resonances decaying into jet pairs in the 325-500 GeV mass range.
NASA Technical Reports Server (NTRS)
1976-01-01
Wide field measurements, namely, measurements of relative angular separations between stars over a relatively wide field for parallax and proper motion determinations, were made with the third fine guidance sensor. Narrow field measurements, i.e., double star measurements, are accomplished primarily with the area photometer or faint object camera at f/96. The wavelength range required can be met by the fine guidance sensor which has a spectral coverage from 3000 to 7500 A. The field of view of the fine guidance sensor also exceeds that required for the wide field astrometric instrument. Requirements require a filter wheel for the wide field astrometer, and so one was incorporated into the design of the fine guidance sensor. The filter wheel probably would contain two neutral density filters to extend the dynamic range of the sensor and three spectral filters for narrowing effective double star magnitude difference.
Li, Guoqi; Deng, Lei; Wang, Dong; Wang, Wei; Zeng, Fei; Zhang, Ziyang; Li, Huanglong; Song, Sen; Pei, Jing; Shi, Luping
2016-01-01
Chunking refers to a phenomenon whereby individuals group items together when performing a memory task to improve the performance of sequential memory. In this work, we build a bio-plausible hierarchical chunking of sequential memory (HCSM) model to explain why such improvement happens. We address this issue by linking hierarchical chunking with synaptic plasticity and neuromorphic engineering. We uncover that a chunking mechanism reduces the requirements of synaptic plasticity since it allows applying synapses with narrow dynamic range and low precision to perform a memory task. We validate a hardware version of the model through simulation, based on measured memristor behavior with narrow dynamic range in neuromorphic circuits, which reveals how chunking works and what role it plays in encoding sequential memory. Our work deepens the understanding of sequential memory and enables incorporating it for the investigation of the brain-inspired computing on neuromorphic architecture. PMID:28066223
Sirunyan, A. M.; Tumasyan, A.; Adam, W.; ...
2018-05-14
A search for narrow resonances decaying to bottom quark-antiquark pairs is presented, using a data sample of proton-proton collisions at s=8 TeV corresponding to an integrated luminosity of 19.7 fb -1. The search is extended to masses lower than those reached in typical searches for resonances decaying into jet pairs at the LHC, by taking advantage of triggers that identify jets originating from bottom quarks. No significant excess of events is observed above the background predictions. Limits are set on the product of cross section and branching fraction to bottom quarks for spin 0, 1, and 2 resonances in themore » mass range of 325–1200 GeV. These results improve on the limits for resonances decaying into jet pairs in the 325–500 GeV mass range.« less
Sirunyan, A M; Tumasyan, A; Adam, W; Ambrogi, F; Asilar, E; Bergauer, T; Brandstetter, J; Brondolin, E; Dragicevic, M; Erö, J; Escalante Del Valle, A; Flechl, M; Friedl, M; Frühwirth, R; Ghete, V M; Grossmann, J; Hrubec, J; Jeitler, M; König, A; Krammer, N; Krätschmer, I; Liko, D; Madlener, T; Mikulec, I; Pree, E; Rad, N; Rohringer, H; Schieck, J; Schöfbeck, R; Spanring, M; Spitzbart, D; Taurok, A; Waltenberger, W; Wittmann, J; Wulz, C-E; Zarucki, M; Chekhovsky, V; Mossolov, V; Suarez Gonzalez, J; De Wolf, E A; Di Croce, D; Janssen, X; Lauwers, J; Pieters, M; Van De Klundert, M; Van Haevermaet, H; Van Mechelen, P; Van Remortel, N; Abu Zeid, S; Blekman, F; D'Hondt, J; De Bruyn, I; De Clercq, J; Deroover, K; Flouris, G; Lontkovskyi, D; Lowette, S; Marchesini, I; Moortgat, S; Moreels, L; Python, Q; Skovpen, K; Tavernier, S; Van Doninck, W; Van Mulders, P; Van Parijs, I; Beghin, D; Bilin, B; Brun, H; Clerbaux, B; De Lentdecker, G; Delannoy, H; Dorney, B; Fasanella, G; Favart, L; Goldouzian, R; Grebenyuk, A; Kalsi, A K; Lenzi, T; Luetic, J; Seva, T; Starling, E; Vander Velde, C; Vanlaer, P; Vannerom, D; Yonamine, R; Cornelis, T; Dobur, D; Fagot, A; Gul, M; Khvastunov, I; Poyraz, D; Roskas, C; Trocino, D; Tytgat, M; Verbeke, W; Vermassen, B; Vit, M; Zaganidis, N; Bakhshiansohi, H; Bondu, O; Brochet, S; Bruno, G; Caputo, C; Caudron, A; David, P; De Visscher, S; Delaere, C; Delcourt, M; Francois, B; Giammanco, A; Krintiras, G; Lemaitre, V; Magitteri, A; Mertens, A; Musich, M; Piotrzkowski, K; Quertenmont, L; Saggio, A; Vidal Marono, M; Wertz, S; Zobec, J; Aldá Júnior, W L; Alves, F L; Alves, G A; Brito, L; Correia Silva, G; Hensel, C; Moraes, A; Pol, M E; Rebello Teles, P; Belchior Batista Das Chagas, E; Carvalho, W; Chinellato, J; Coelho, E; Da Costa, E M; Da Silveira, G G; De Jesus Damiao, D; Fonseca De Souza, S; Malbouisson, H; Medina Jaime, M; Melo De Almeida, M; Mora Herrera, C; Mundim, L; Nogima, H; Sanchez Rosas, L J; Santoro, A; Sznajder, A; Thiel, M; Tonelli Manganote, E J; Torres Da Silva De Araujo, F; Vilela Pereira, A; Ahuja, S; Bernardes, C A; Calligaris, L; Tomei, T R Fernandez Perez; Gregores, E M; Mercadante, P G; Novaes, S F; Padula, Sandra S; Romero Abad, D; Ruiz Vargas, J C; Aleksandrov, A; Hadjiiska, R; Iaydjiev, P; Marinov, A; Misheva, M; Rodozov, M; Shopova, M; Sultanov, G; Dimitrov, A; Litov, L; Pavlov, B; Petkov, P; Fang, W; Gao, X; Yuan, L; Ahmad, M; Bian, J G; Chen, G M; Chen, H S; Chen, M; Chen, Y; Jiang, C H; Leggat, D; Liao, H; Liu, Z; Romeo, F; Shaheen, S M; Spiezia, A; Tao, J; Wang, C; Wang, Z; Yazgan, E; Zhang, H; Zhao, J; Ban, Y; Chen, G; Li, J; Li, Q; Liu, S; Mao, Y; Qian, S J; Wang, D; Xu, Z; Wang, Y; Avila, C; Cabrera, A; Carrillo Montoya, C A; Chaparro Sierra, L F; Florez, C; González Hernández, C F; Segura Delgado, M A; Courbon, B; Godinovic, N; Lelas, D; Puljak, I; Ribeiro Cipriano, P M; Sculac, T; Antunovic, Z; Kovac, M; Brigljevic, V; Ferencek, D; Kadija, K; Mesic, B; Starodumov, A; Susa, T; Ather, M W; Attikis, A; Mavromanolakis, G; Mousa, J; Nicolaou, C; Ptochos, F; Razis, P A; Rykaczewski, H; Finger, M; Finger, M; Carrera Jarrin, E; Assran, Y; Elgammal, S; Mahmoud, M A; Bhowmik, S; Dewanjee, R K; Kadastik, M; Perrini, L; Raidal, M; Veelken, C; Eerola, P; Kirschenmann, H; Pekkanen, J; Voutilainen, M; Havukainen, J; Heikkilä, J K; Järvinen, T; Karimäki, V; Kinnunen, R; Lampén, T; Lassila-Perini, K; Laurila, S; Lehti, S; Lindén, T; Luukka, P; Mäenpää, T; Siikonen, H; Tuominen, E; Tuominiemi, J; Tuuva, T; Besancon, M; Couderc, F; Dejardin, M; Denegri, D; Faure, J L; Ferri, F; Ganjour, S; Ghosh, S; Givernaud, A; Gras, P; Hamel de Monchenault, G; Jarry, P; Leloup, C; Locci, E; Machet, M; Malcles, J; Negro, G; Rander, J; Rosowsky, A; Sahin, M Ö; Titov, M; Abdulsalam, A; Amendola, C; Antropov, I; Baffioni, S; Beaudette, F; Busson, P; Cadamuro, L; Charlot, C; Granier de Cassagnac, R; Jo, M; Kucher, I; Lisniak, S; Lobanov, A; Martin Blanco, J; Nguyen, M; Ochando, C; Ortona, G; Paganini, P; Pigard, P; Salerno, R; Sauvan, J B; Sirois, Y; Stahl Leiton, A G; Yilmaz, Y; Zabi, A; Zghiche, A; Agram, J-L; Andrea, J; Bloch, D; Brom, J-M; Chabert, E C; Collard, C; Conte, E; Coubez, X; Drouhin, F; Fontaine, J-C; Gelé, D; Goerlach, U; Jansová, M; Juillot, P; Le Bihan, A-C; Tonon, N; Van Hove, P; Gadrat, S; Beauceron, S; Bernet, C; Boudoul, G; Chanon, N; Chierici, R; Contardo, D; Depasse, P; El Mamouni, H; Fay, J; Finco, L; Gascon, S; Gouzevitch, M; Grenier, G; Ille, B; Lagarde, F; Laktineh, I B; Lattaud, H; Lethuillier, M; Mirabito, L; Pequegnot, A L; Perries, S; Popov, A; Sordini, V; Vander Donckt, M; Viret, S; Zhang, S; Toriashvili, T; Tsamalaidze, Z; Autermann, C; Feld, L; Kiesel, M K; Klein, K; Lipinski, M; Preuten, M; Rauch, M P; Schomakers, C; Schulz, J; Teroerde, M; Wittmer, B; Zhukov, V; Albert, A; Duchardt, D; Endres, M; Erdmann, M; Erdweg, S; Esch, T; Fischer, R; Güth, A; Hebbeker, T; Heidemann, C; Hoepfner, K; Knutzen, S; Merschmeyer, M; Meyer, A; Millet, P; Mukherjee, S; Pook, T; Radziej, M; Reithler, H; Rieger, M; Scheuch, F; Teyssier, D; Thüer, S; Flügge, G; Kargoll, B; Kress, T; Künsken, A; Müller, T; Nehrkorn, A; Nowack, A; Pistone, C; Pooth, O; Stahl, A; Aldaya Martin, M; Arndt, T; Asawatangtrakuldee, C; Beernaert, K; Behnke, O; Behrens, U; Bermúdez Martínez, A; Bin Anuar, A A; Borras, K; Botta, V; Campbell, A; Connor, P; Contreras-Campana, C; Costanza, F; Danilov, V; De Wit, A; Diez Pardos, C; Domínguez Damiani, D; Eckerlin, G; Eckstein, D; Eichhorn, T; Elwood, A; Eren, E; Gallo, E; Garay Garcia, J; Geiser, A; Grados Luyando, J M; Grohsjean, A; Gunnellini, P; Guthoff, M; Harb, A; Hauk, J; Jung, H; Kasemann, M; Keaveney, J; Kleinwort, C; Knolle, J; Korol, I; Krücker, D; Lange, W; Lelek, A; Lenz, T; Lipka, K; Lohmann, W; Mankel, R; Melzer-Pellmann, I-A; Meyer, A B; Meyer, M; Missiroli, M; Mittag, G; Mnich, J; Mussgiller, A; Pitzl, D; Raspereza, A; Savitskyi, M; Saxena, P; Shevchenko, R; Stefaniuk, N; Tholen, H; Van Onsem, G P; Walsh, R; Wen, Y; Wichmann, K; Wissing, C; Zenaiev, O; Aggleton, R; Bein, S; Blobel, V; Centis Vignali, M; Dreyer, T; Garutti, E; Gonzalez, D; Haller, J; Hinzmann, A; Hoffmann, M; Karavdina, A; Kasieczka, G; Klanner, R; Kogler, R; Kovalchuk, N; Kurz, S; Kutzner, V; Lange, J; Marconi, D; Multhaup, J; Niedziela, M; Nowatschin, D; Peiffer, T; Perieanu, A; Reimers, A; Scharf, C; Schleper, P; Schmidt, A; Schumann, S; Schwandt, J; Sonneveld, J; Stadie, H; Steinbrück, G; Stober, F M; Stöver, M; Troendle, D; Usai, E; Vanhoefer, A; Vormwald, B; Akbiyik, M; Barth, C; Baselga, M; Baur, S; Butz, E; Caspart, R; Chwalek, T; Colombo, F; De Boer, W; Dierlamm, A; Faltermann, N; Freund, B; Friese, R; Giffels, M; Harrendorf, M A; Hartmann, F; Heindl, S M; Husemann, U; Kassel, F; Kudella, S; Mildner, H; Mozer, M U; Müller, Th; Plagge, M; Quast, G; Rabbertz, K; Schröder, M; Shvetsov, I; Sieber, G; Simonis, H J; Ulrich, R; Wayand, S; Weber, M; Weiler, T; Williamson, S; Wöhrmann, C; Wolf, R; Anagnostou, G; Daskalakis, G; Geralis, T; Kyriakis, A; Loukas, D; Topsis-Giotis, I; Karathanasis, G; Kesisoglou, S; Panagiotou, A; Saoulidou, N; Tziaferi, E; Kousouris, K; Papakrivopoulos, I; Evangelou, I; Foudas, C; Gianneios, P; Katsoulis, P; Kokkas, P; Mallios, S; Manthos, N; Papadopoulos, I; Paradas, E; Strologas, J; Triantis, F A; Tsitsonis, D; Csanad, M; Filipovic, N; Pasztor, G; Surányi, O; Veres, G I; Bencze, G; Hajdu, C; Horvath, D; Hunyadi, Á; Sikler, F; Veszpremi, V; Vesztergombi, G; Vámi, T Á; Beni, N; Czellar, S; Karancsi, J; Makovec, A; Molnar, J; Szillasi, Z; Bartók, M; Raics, P; Trocsanyi, Z L; Ujvari, B; Choudhury, S; Komaragiri, J R; Bahinipati, S; Mal, P; Mandal, K; Nayak, A; Sahoo, D K; Swain, S K; Bansal, S; Beri, S B; Bhatnagar, V; Chauhan, S; Chawla, R; Dhingra, N; Gupta, R; Kaur, A; Kaur, M; Kaur, S; Kumar, R; Kumari, P; Lohan, M; Mehta, A; Sharma, S; Singh, J B; Walia, G; Kumar, Ashok; Shah, Aashaq; Bhardwaj, A; Choudhary, B C; Garg, R B; Keshri, S; Kumar, A; Malhotra, S; Naimuddin, M; Ranjan, K; Sharma, R; Bhardwaj, R; Bhattacharya, R; Bhattacharya, S; Bhawandeep, U; Bhowmik, D; Dey, S; Dutt, S; Dutta, S; Ghosh, S; Majumdar, N; Mondal, K; Mukhopadhyay, S; Nandan, S; Purohit, A; Rout, P K; Roy, A; Roy Chowdhury, S; Sarkar, S; Sharan, M; Singh, B; Thakur, S; Behera, P K; Chudasama, R; Dutta, D; Jha, V; Kumar, V; Mohanty, A K; Netrakanti, P K; Pant, L M; Shukla, P; Topkar, A; Aziz, T; Dugad, S; Mahakud, B; Mitra, S; Mohanty, G B; Sur, N; Sutar, B; Banerjee, S; Bhattacharya, S; Chatterjee, S; Das, P; Guchait, M; Jain, Sa; Kumar, S; Maity, M; Majumder, G; Mazumdar, K; Sahoo, N; Sarkar, T; Wickramage, N; Chauhan, S; Dube, S; Hegde, V; Kapoor, A; Kothekar, K; Pandey, S; Rane, A; Sharma, S; Chenarani, S; Eskandari Tadavani, E; Etesami, S M; Khakzad, M; Mohammadi Najafabadi, M; Naseri, M; Paktinat Mehdiabadi, S; Rezaei Hosseinabadi, F; Safarzadeh, B; Zeinali, M; Felcini, M; Grunewald, M; Abbrescia, M; Calabria, C; Colaleo, A; Creanza, D; Cristella, L; De Filippis, N; De Palma, M; Di Florio, A; Errico, F; Fiore, L; Gelmi, A; Iaselli, G; Lezki, S; Maggi, G; Maggi, M; Marangelli, B; Miniello, G; My, S; Nuzzo, S; Pompili, A; Pugliese, G; Radogna, R; Ranieri, A; Selvaggi, G; Sharma, A; Silvestris, L; Venditti, R; Verwilligen, P; Zito, G; Abbiendi, G; Battilana, C; Bonacorsi, D; Borgonovi, L; Braibant-Giacomelli, S; Campanini, R; Capiluppi, P; Castro, A; Cavallo, F R; Chhibra, S S; Codispoti, G; Cuffiani, M; Dallavalle, G M; Fabbri, F; Fanfani, A; Fasanella, D; Giacomelli, P; Grandi, C; Guiducci, L; Iemmi, F; Marcellini, S; Masetti, G; Montanari, A; Navarria, F L; Perrotta, A; Rossi, A M; Rovelli, T; Siroli, G P; Tosi, N; Albergo, S; Costa, S; Di Mattia, A; Giordano, F; Potenza, R; Tricomi, A; Tuve, C; Barbagli, G; Chatterjee, K; Ciulli, V; Civinini, C; D'Alessandro, R; Focardi, E; Latino, G; Lenzi, P; Meschini, M; Paoletti, S; Russo, L; Sguazzoni, G; Strom, D; Viliani, L; Benussi, L; Bianco, S; Fabbri, F; Piccolo, D; Primavera, F; Calvelli, V; Ferro, F; Ravera, F; Robutti, E; Tosi, S; Benaglia, A; Beschi, A; Brianza, L; Brivio, F; Ciriolo, V; Dinardo, M E; Fiorendi, S; Gennai, S; Ghezzi, A; Govoni, P; Malberti, M; Malvezzi, S; Manzoni, R A; Menasce, D; Moroni, L; Paganoni, M; Pauwels, K; Pedrini, D; Pigazzini, S; Ragazzi, S; Tabarelli de Fatis, T; Buontempo, S; Cavallo, N; Di Guida, S; Fabozzi, F; Fienga, F; Galati, G; Iorio, A O M; Khan, W A; Lista, L; Meola, S; Paolucci, P; Sciacca, C; Thyssen, F; Voevodina, E; Azzi, P; Bacchetta, N; Benato, L; Bisello, D; Boletti, A; Carlin, R; Carvalho Antunes De Oliveira, A; Checchia, P; De Castro Manzano, P; Dorigo, T; Dosselli, U; Gasparini, F; Gasparini, U; Gozzelino, A; Lacaprara, S; Margoni, M; Meneguzzo, A T; Pozzobon, N; Ronchese, P; Rossin, R; Simonetto, F; Tiko, A; Torassa, E; Zanetti, M; Zotto, P; Zumerle, G; Braghieri, A; Magnani, A; Montagna, P; Ratti, S P; Re, V; Ressegotti, M; Riccardi, C; Salvini, P; Vai, I; Vitulo, P; Alunni Solestizi, L; Biasini, M; Bilei, G M; Cecchi, C; Ciangottini, D; Fanò, L; Lariccia, P; Leonardi, R; Manoni, E; Mantovani, G; Mariani, V; Menichelli, M; Rossi, A; Santocchia, A; Spiga, D; Androsov, K; Azzurri, P; Bagliesi, G; Bianchini, L; Boccali, T; Borrello, L; Castaldi, R; Ciocci, M A; Dell'Orso, R; Fedi, G; Giannini, L; Giassi, A; Grippo, M T; Ligabue, F; Lomtadze, T; Manca, E; Mandorli, G; Messineo, A; Palla, F; Rizzi, A; Spagnolo, P; Tenchini, R; Tonelli, G; Venturi, A; Verdini, P G; Barone, L; Cavallari, F; Cipriani, M; Daci, N; Del Re, D; Di Marco, E; Diemoz, M; Gelli, S; Longo, E; Marzocchi, B; Meridiani, P; Organtini, G; Pandolfi, F; Paramatti, R; Preiato, F; Rahatlou, S; Rovelli, C; Santanastasio, F; Amapane, N; Arcidiacono, R; Argiro, S; Arneodo, M; Bartosik, N; Bellan, R; Biino, C; Cartiglia, N; Castello, R; Cenna, F; Costa, M; Covarelli, R; Degano, A; Demaria, N; Kiani, B; Mariotti, C; Maselli, S; Migliore, E; Monaco, V; Monteil, E; Monteno, M; Obertino, M M; Pacher, L; Pastrone, N; Pelliccioni, M; Pinna Angioni, G L; Romero, A; Ruspa, M; Sacchi, R; Shchelina, K; Sola, V; Solano, A; Staiano, A; Belforte, S; Casarsa, M; Cossutti, F; Della Ricca, G; Zanetti, A; Kim, D H; Kim, G N; Kim, M S; Lee, J; Lee, S; Lee, S W; Moon, C S; Oh, Y D; Sekmen, S; Son, D C; Yang, Y C; Kim, H; Moon, D H; Oh, G; Brochero Cifuentes, J A; Goh, J; Kim, T J; Cho, S; Choi, S; Go, Y; Gyun, D; Ha, S; Hong, B; Jo, Y; Kim, Y; Lee, K; Lee, K S; Lee, S; Lim, J; Park, S K; Roh, Y; Almond, J; Kim, J; Kim, J S; Lee, H; Lee, K; Nam, K; Oh, S B; Radburn-Smith, B C; Seo, S H; Yang, U K; Yoo, H D; Yu, G B; Kim, H; Kim, J H; Lee, J S H; Park, I C; Choi, Y; Hwang, C; Lee, J; Yu, I; Dudenas, V; Juodagalvis, A; Vaitkus, J; Ahmed, I; Ibrahim, Z A; Md Ali, M A B; Mohamad Idris, F; Wan Abdullah, W A T; Yusli, M N; Zolkapli, Z; Reyes-Almanza, R; Ramirez-Sanchez, G; Duran-Osuna, M C; Castilla-Valdez, H; De La Cruz-Burelo, E; Heredia-De La Cruz, I; Rabadan-Trejo, R I; Lopez-Fernandez, R; Mejia Guisao, J; Sanchez-Hernandez, A; Carrillo Moreno, S; Oropeza Barrera, C; Vazquez Valencia, F; Eysermans, J; Pedraza, I; Salazar Ibarguen, H A; Uribe Estrada, C; Morelos Pineda, A; Krofcheck, D; Butler, P H; Ahmad, A; Ahmad, M; Hassan, Q; Hoorani, H R; Saddique, A; Shah, M A; Shoaib, M; Waqas, M; Bialkowska, H; Bluj, M; Boimska, B; Frueboes, T; Górski, M; Kazana, M; Nawrocki, K; Szleper, M; Traczyk, P; Zalewski, P; Bunkowski, K; Byszuk, A; Doroba, K; Kalinowski, A; Konecki, M; Krolikowski, J; Misiura, M; Olszewski, M; Pyskir, A; Walczak, M; Bargassa, P; Beirão Da Cruz E Silva, C; Di Francesco, A; Faccioli, P; Galinhas, B; Gallinaro, M; Hollar, J; Leonardo, N; Lloret Iglesias, L; Nemallapudi, M V; Seixas, J; Strong, G; Toldaiev, O; Vadruccio, D; Varela, J; Afanasiev, S; Bunin, P; Gavrilenko, M; Golutvin, I; Gorbunov, I; Kamenev, A; Karjavin, V; Lanev, A; Malakhov, A; Matveev, V; Moisenz, P; Palichik, V; Perelygin, V; Shmatov, S; Shulha, S; Skatchkov, N; Smirnov, V; Voytishin, N; Zarubin, A; Ivanov, Y; Kim, V; Kuznetsova, E; Levchenko, P; Murzin, V; Oreshkin, V; Smirnov, I; Sosnov, D; Sulimov, V; Uvarov, L; Vavilov, S; Vorobyev, A; Andreev, Yu; Dermenev, A; Gninenko, S; Golubev, N; Karneyeu, A; Kirsanov, M; Krasnikov, N; Pashenkov, A; Tlisov, D; Toropin, A; Epshteyn, V; Gavrilov, V; Lychkovskaya, N; Popov, V; Pozdnyakov, I; Safronov, G; Spiridonov, A; Stepennov, A; Stolin, V; Toms, M; Vlasov, E; Zhokin, A; Aushev, T; Bylinkin, A; Chistov, R; Danilov, M; Parygin, P; Philippov, D; Polikarpov, S; Tarkovskii, E; Andreev, V; Azarkin, M; Dremin, I; Kirakosyan, M; Rusakov, S V; Terkulov, A; Baskakov, A; Belyaev, A; Boos, E; Dubinin, M; Dudko, L; Ershov, A; Gribushin, A; Klyukhin, V; Kodolova, O; Lokhtin, I; Miagkov, I; Obraztsov, S; Petrushanko, S; Savrin, V; Snigirev, A; Blinov, V; Shtol, D; Skovpen, Y; Azhgirey, I; Bayshev, I; Bitioukov, S; Elumakhov, D; Godizov, A; Kachanov, V; Kalinin, A; Konstantinov, D; Mandrik, P; Petrov, V; Ryutin, R; Sobol, A; Troshin, S; Tyurin, N; Uzunian, A; Volkov, A; Babaev, A; Adzic, P; Cirkovic, P; Devetak, D; Dordevic, M; Milosevic, J; Alcaraz Maestre, J; Bachiller, I; Barrio Luna, M; Cerrada, M; Colino, N; De La Cruz, B; Delgado Peris, A; Fernandez Bedoya, C; Fernández Ramos, J P; Flix, J; Fouz, M C; Gonzalez Lopez, O; Goy Lopez, S; Hernandez, J M; Josa, M I; Moran, D; Pérez-Calero Yzquierdo, A; Puerta Pelayo, J; Redondo, I; Romero, L; Soares, M S; Triossi, A; Álvarez Fernández, A; Albajar, C; de Trocóniz, J F; Cuevas, J; Erice, C; Fernandez Menendez, J; Folgueras, S; Gonzalez Caballero, I; González Fernández, J R; Palencia Cortezon, E; Sanchez Cruz, S; Vischia, P; Vizan Garcia, J M; Cabrillo, I J; Calderon, A; Chazin Quero, B; Duarte Campderros, J; Fernandez, M; Fernández Manteca, P J; Garcia-Ferrero, J; García Alonso, A; Gomez, G; Lopez Virto, A; Marco, J; Martinez Rivero, C; Martinez Ruiz Del Arbol, P; Matorras, F; Piedra Gomez, J; Prieels, C; Rodrigo, T; Ruiz-Jimeno, A; Scodellaro, L; Trevisani, N; Vila, I; Vilar Cortabitarte, R; Abbaneo, D; Akgun, B; Auffray, E; Baillon, P; Ball, A H; Barney, D; Bendavid, J; Bianco, M; Bocci, A; Botta, C; Camporesi, T; Cepeda, M; Cerminara, G; Chapon, E; Chen, Y; d'Enterria, D; Dabrowski, A; Daponte, V; David, A; De Gruttola, M; De Roeck, A; Deelen, N; Dobson, M; du Pree, T; Dünser, M; Dupont, N; Elliott-Peisert, A; Everaerts, P; Fallavollita, F; Franzoni, G; Fulcher, J; Funk, W; Gigi, D; Gilbert, A; Gill, K; Glege, F; Gulhan, D; Hegeman, J; Innocente, V; Jafari, A; Janot, P; Karacheban, O; Kieseler, J; Knünz, V; Kornmayer, A; Krammer, M; Lange, C; Lecoq, P; Lourenço, C; Lucchini, M T; Malgeri, L; Mannelli, M; Martelli, A; Meijers, F; Merlin, J A; Mersi, S; Meschi, E; Milenovic, P; Moortgat, F; Mulders, M; Neugebauer, H; Ngadiuba, J; Orfanelli, S; Orsini, L; Pantaleo, F; Pape, L; Perez, E; Peruzzi, M; Petrilli, A; Petrucciani, G; Pfeiffer, A; Pierini, M; Pitters, F M; Rabady, D; Racz, A; Reis, T; Rolandi, G; Rovere, M; Sakulin, H; Schäfer, C; Schwick, C; Seidel, M; Selvaggi, M; Sharma, A; Silva, P; Sphicas, P; Stakia, A; Steggemann, J; Stoye, M; Tosi, M; Treille, D; Tsirou, A; Veckalns, V; Verweij, M; Zeuner, W D; Bertl, W; Caminada, L; Deiters, K; Erdmann, W; Horisberger, R; Ingram, Q; Kaestli, H C; Kotlinski, D; Langenegger, U; Rohe, T; Wiederkehr, S A; Backhaus, M; Bäni, L; Berger, P; Casal, B; Chernyavskaya, N; Dissertori, G; Dittmar, M; Donegà, M; Dorfer, C; Grab, C; Heidegger, C; Hits, D; Hoss, J; Klijnsma, T; Lustermann, W; Marionneau, M; Meinhard, M T; Meister, D; Micheli, F; Musella, P; Nessi-Tedaldi, F; Pata, J; Pauss, F; Perrin, G; Perrozzi, L; Quittnat, M; Reichmann, M; Ruini, D; Sanz Becerra, D A; Schönenberger, M; Shchutska, L; Tavolaro, V R; Theofilatos, K; Vesterbacka Olsson, M L; Wallny, R; Zhu, D H; Aarrestad, T K; Amsler, C; Brzhechko, D; Canelli, M F; De Cosa, A; Del Burgo, R; Donato, S; Galloni, C; Hreus, T; Kilminster, B; Neutelings, I; Pinna, D; Rauco, G; Robmann, P; Salerno, D; Schweiger, K; Seitz, C; Takahashi, Y; Zucchetta, A; Candelise, V; Chang, Y H; Cheng, K Y; Doan, T H; Jain, Sh; Khurana, R; Kuo, C M; Lin, W; Pozdnyakov, A; Yu, S S; Kumar, Arun; Chang, P; Chao, Y; Chen, K F; Chen, P H; Fiori, F; Hou, W-S; Hsiung, Y; Liu, Y F; Lu, R-S; Paganis, E; Psallidas, A; Steen, A; Tsai, J F; Asavapibhop, B; Kovitanggoon, K; Singh, G; Srimanobhas, N; Bat, A; Boran, F; Cerci, S; Damarseckin, S; Demiroglu, Z S; Dozen, C; Dumanoglu, I; Girgis, S; Gokbulut, G; Guler, Y; Hos, I; Kangal, E E; Kara, O; Kiminsu, U; Oglakci, M; Onengut, G; Ozdemir, K; Sunar Cerci, D; Tali, B; Tok, U G; Topakli, H; Turkcapar, S; Zorbakir, I S; Zorbilmez, C; Karapinar, G; Ocalan, K; Yalvac, M; Zeyrek, M; Atakisi, I O; Gülmez, E; Kaya, M; Kaya, O; Tekten, S; Yetkin, E A; Agaras, M N; Atay, S; Cakir, A; Cankocak, K; Komurcu, Y; Grynyov, B; Levchuk, L; Ball, F; Beck, L; Brooke, J J; Burns, D; Clement, E; Cussans, D; Davignon, O; Flacher, H; Goldstein, J; Heath, G P; Heath, H F; Kreczko, L; Newbold, D M; Paramesvaran, S; Sakuma, T; Seif El Nasr-Storey, S; Smith, D; Smith, V J; Bell, K W; Belyaev, A; Brew, C; Brown, R M; Cieri, D; Cockerill, D J A; Coughlan, J A; Harder, K; Harper, S; Linacre, J; Olaiya, E; Petyt, D; Shepherd-Themistocleous, C H; Thea, A; Tomalin, I R; Williams, T; Womersley, W J; Auzinger, G; Bainbridge, R; Bloch, P; Borg, J; Breeze, S; Buchmuller, O; Bundock, A; Casasso, S; Colling, D; Corpe, L; Dauncey, P; Davies, G; Della Negra, M; Di Maria, R; Haddad, Y; Hall, G; Iles, G; James, T; Komm, M; Lane, R; Laner, C; Lyons, L; Magnan, A-M; Malik, S; Mastrolorenzo, L; Matsushita, T; Nash, J; Nikitenko, A; Palladino, V; Pesaresi, M; Richards, A; Rose, A; Scott, E; Seez, C; Shtipliyski, A; Strebler, T; Summers, S; Tapper, A; Uchida, K; Vazquez Acosta, M; Virdee, T; Wardle, N; Winterbottom, D; Wright, J; Zenz, S C; Cole, J E; Hobson, P R; Khan, A; Kyberd, P; Morton, A; Reid, I D; Teodorescu, L; Zahid, S; Borzou, A; Call, K; Dittmann, J; Hatakeyama, K; Liu, H; Pastika, N; Smith, C; Bartek, R; Dominguez, A; Buccilli, A; Cooper, S I; Henderson, C; Rumerio, P; West, C; Arcaro, D; Avetisyan, A; Bose, T; Gastler, D; Rankin, D; Richardson, C; Rohlf, J; Sulak, L; Zou, D; Benelli, G; Cutts, D; Hadley, M; Hakala, J; Heintz, U; Hogan, J M; Kwok, K H M; Laird, E; Landsberg, G; Lee, J; Mao, Z; Morrison, T; Narain, M; Pazzini, J; Piperov, S; Sagir, S; Syarif, R; Yu, D; Band, R; Brainerd, C; Breedon, R; Burns, D; Calderon De La Barca Sanchez, M; Chertok, M; Conway, J; Conway, R; Cox, P T; Erbacher, R; Flores, C; Funk, G; Ko, W; Lander, R; Mclean, C; Mulhearn, M; Pellett, D; Pilot, J; Shalhout, S; Shi, M; Smith, J; Stolp, D; Taylor, D; Tos, K; Tripathi, M; Wang, Z; Zhang, F; Bachtis, M; Bravo, C; Cousins, R; Dasgupta, A; Florent, A; Hauser, J; Ignatenko, M; Mccoll, N; Regnard, S; Saltzberg, D; Schnaible, C; Valuev, V; Bouvier, E; Burt, K; Clare, R; Ellison, J; Gary, J W; Ghiasi Shirazi, S M A; Hanson, G; Karapostoli, G; Kennedy, E; Lacroix, F; Long, O R; Olmedo Negrete, M; Paneva, M I; Si, W; Wang, L; Wei, H; Wimpenny, S; Yates, B R; Branson, J G; Cittolin, S; Derdzinski, M; Gerosa, R; Gilbert, D; Hashemi, B; Holzner, A; Klein, D; Kole, G; Krutelyov, V; Letts, J; Masciovecchio, M; Olivito, D; Padhi, S; Pieri, M; Sani, M; Sharma, V; Simon, S; Tadel, M; Vartak, A; Wasserbaech, S; Wood, J; Würthwein, F; Yagil, A; Zevi Della Porta, G; Amin, N; Bhandari, R; Bradmiller-Feld, J; Campagnari, C; Citron, M; Dishaw, A; Dutta, V; Franco Sevilla, M; Gouskos, L; Heller, R; Incandela, J; Ovcharova, A; Qu, H; Richman, J; Stuart, D; Suarez, I; Yoo, J; Anderson, D; Bornheim, A; Bunn, J; Lawhorn, J M; Newman, H B; Nguyen, T Q; Pena, C; Spiropulu, M; Vlimant, J R; Wilkinson, R; Xie, S; Zhang, Z; Zhu, R Y; Andrews, M B; Ferguson, T; Mudholkar, T; Paulini, M; Russ, J; Sun, M; Vogel, H; Vorobiev, I; Weinberg, M; Cumalat, J P; Ford, W T; Jensen, F; Johnson, A; Krohn, M; Leontsinis, S; MacDonald, E; Mulholland, T; Stenson, K; Ulmer, K A; Wagner, S R; Alexander, J; Chaves, J; Cheng, Y; Chu, J; Datta, A; Mcdermott, K; Mirman, N; Patterson, J R; Quach, D; Rinkevicius, A; Ryd, A; Skinnari, L; Soffi, L; Tan, S M; Tao, Z; Thom, J; Tucker, J; Wittich, P; Zientek, M; Abdullin, S; Albrow, M; Alyari, M; Apollinari, G; Apresyan, A; Apyan, A; Banerjee, S; Bauerdick, L A T; Beretvas, A; Berryhill, J; Bhat, P C; Bolla, G; Burkett, K; Butler, J N; Canepa, A; Cerati, G B; Cheung, H W K; Chlebana, F; Cremonesi, M; Duarte, J; Elvira, V D; Freeman, J; Gecse, Z; Gottschalk, E; Gray, L; Green, D; Grünendahl, S; Gutsche, O; Hanlon, J; Harris, R M; Hasegawa, S; Hirschauer, J; Hu, Z; Jayatilaka, B; Jindariani, S; Johnson, M; Joshi, U; Klima, B; Kortelainen, M J; Kreis, B; Lammel, S; Lincoln, D; Lipton, R; Liu, M; Liu, T; Lopes De Sá, R; Lykken, J; Maeshima, K; Magini, N; Marraffino, J M; Mason, D; McBride, P; Merkel, P; Mrenna, S; Nahn, S; O'Dell, V; Pedro, K; Prokofyev, O; Rakness, G; Ristori, L; Savoy-Navarro, A; Schneider, B; Sexton-Kennedy, E; Soha, A; Spalding, W J; Spiegel, L; Stoynev, S; Strait, J; Strobbe, N; Taylor, L; Tkaczyk, S; Tran, N V; Uplegger, L; Vaandering, E W; Vernieri, C; Verzocchi, M; Vidal, R; Wang, M; Weber, H A; Whitbeck, A; Wu, W; Acosta, D; Avery, P; Bortignon, P; Bourilkov, D; Brinkerhoff, A; Carnes, A; Carver, M; Curry, D; Field, R D; Furic, I K; Gleyzer, S V; Joshi, B M; Konigsberg, J; Korytov, A; Kotov, K; Ma, P; Matchev, K; Mei, H; Mitselmakher, G; Shi, K; Sperka, D; Terentyev, N; Thomas, L; Wang, J; Wang, S; Yelton, J; Joshi, Y R; Linn, S; Markowitz, P; Rodriguez, J L; Ackert, A; Adams, T; Askew, A; Hagopian, S; Hagopian, V; Johnson, K F; Kolberg, T; Martinez, G; Perry, T; Prosper, H; Saha, A; Santra, A; Sharma, V; Yohay, R; Baarmand, M M; Bhopatkar, V; Colafranceschi, S; Hohlmann, M; Noonan, D; Roy, T; Yumiceva, F; Adams, M R; Apanasevich, L; Berry, D; Betts, R R; Cavanaugh, R; Chen, X; Dittmer, S; Evdokimov, O; Gerber, C E; Hangal, D A; Hofman, D J; Jung, K; Kamin, J; Sandoval Gonzalez, I D; Tonjes, M B; Varelas, N; Wang, H; Wu, Z; Zhang, J; Bilki, B; Clarida, W; Dilsiz, K; Durgut, S; Gandrajula, R P; Haytmyradov, M; Khristenko, V; Merlo, J-P; Mermerkaya, H; Mestvirishvili, A; Moeller, A; Nachtman, J; Ogul, H; Onel, Y; Ozok, F; Penzo, A; Snyder, C; Tiras, E; Wetzel, J; Yi, K; Blumenfeld, B; Cocoros, A; Eminizer, N; Fehling, D; Feng, L; Gritsan, A V; Hung, W T; Maksimovic, P; Roskes, J; Sarica, U; Swartz, M; Xiao, M; You, C; Al-Bataineh, A; Baringer, P; Bean, A; Boren, S; Bowen, J; Castle, J; Khalil, S; Kropivnitskaya, A; Majumder, D; Mcbrayer, W; Murray, M; Rogan, C; Royon, C; Sanders, S; Schmitz, E; Tapia Takaki, J D; Wang, Q; Ivanov, A; Kaadze, K; Maravin, Y; Modak, A; Mohammadi, A; Saini, L K; Skhirtladze, N; Rebassoo, F; Wright, D; Baden, A; Baron, O; Belloni, A; Eno, S C; Feng, Y; Ferraioli, C; Hadley, N J; Jabeen, S; Jeng, G Y; Kellogg, R G; Kunkle, J; Mignerey, A C; Ricci-Tam, F; Shin, Y H; Skuja, A; Tonwar, S C; Abercrombie, D; Allen, B; Azzolini, V; Barbieri, R; Baty, A; Bauer, G; Bi, R; Brandt, S; Busza, W; Cali, I A; D'Alfonso, M; Demiragli, Z; Gomez Ceballos, G; Goncharov, M; Harris, P; Hsu, D; Hu, M; Iiyama, Y; Innocenti, G M; Klute, M; Kovalskyi, D; Lee, Y-J; Levin, A; Luckey, P D; Maier, B; Marini, A C; Mcginn, C; Mironov, C; Narayanan, S; Niu, X; Paus, C; Roland, C; Roland, G; Stephans, G S F; Sumorok, K; Tatar, K; Velicanu, D; Wang, J; Wang, T W; Wyslouch, B; Zhaozhong, S; Benvenuti, A C; Chatterjee, R M; Evans, A; Hansen, P; Kalafut, S; Kubota, Y; Lesko, Z; Mans, J; Nourbakhsh, S; Ruckstuhl, N; Rusack, R; Turkewitz, J; Wadud, M A; Acosta, J G; Oliveros, S; Avdeeva, E; Bloom, K; Claes, D R; Fangmeier, C; Golf, F; Gonzalez Suarez, R; Kamalieddin, R; Kravchenko, I; Monroy, J; Siado, J E; Snow, G R; Stieger, B; Godshalk, A; Harrington, C; Iashvili, I; Nguyen, D; Parker, A; Rappoccio, S; Roozbahani, B; Alverson, G; Barberis, E; Freer, C; Hortiangtham, A; Massironi, A; Morse, D M; Orimoto, T; Teixeira De Lima, R; Wamorkar, T; Wang, B; Wisecarver, A; Wood, D; Bhattacharya, S; Charaf, O; Hahn, K A; Mucia, N; Odell, N; Schmitt, M H; Sung, K; Trovato, M; Velasco, M; Bucci, R; Dev, N; Hildreth, M; Hurtado Anampa, K; Jessop, C; Karmgard, D J; Kellams, N; Lannon, K; Li, W; Loukas, N; Marinelli, N; Meng, F; Mueller, C; Musienko, Y; Planer, M; Reinsvold, A; Ruchti, R; Siddireddy, P; Smith, G; Taroni, S; Wayne, M; Wightman, A; Wolf, M; Woodard, A; Alimena, J; Antonelli, L; Bylsma, B; Durkin, L S; Flowers, S; Francis, B; Hart, A; Hill, C; Ji, W; Ling, T Y; Luo, W; Winer, B L; Wulsin, H W; Cooperstein, S; Driga, O; Elmer, P; Hardenbrook, J; Hebda, P; Higginbotham, S; Kalogeropoulos, A; Lange, D; Luo, J; Marlow, D; Mei, K; Ojalvo, I; Olsen, J; Palmer, C; Piroué, P; Salfeld-Nebgen, J; Stickland, D; Tully, C; Malik, S; Norberg, S; Barker, A; Barnes, V E; Das, S; Gutay, L; Jones, M; Jung, A W; Khatiwada, A; Miller, D H; Neumeister, N; Peng, C C; Qiu, H; Schulte, J F; Sun, J; Wang, F; Xiao, R; Xie, W; Cheng, T; Dolen, J; Parashar, N; Chen, Z; Ecklund, K M; Freed, S; Geurts, F J M; Guilbaud, M; Kilpatrick, M; Li, W; Michlin, B; Padley, B P; Roberts, J; Rorie, J; Shi, W; Tu, Z; Zabel, J; Zhang, A; Bodek, A; de Barbaro, P; Demina, R; Duh, Y T; Ferbel, T; Galanti, M; Garcia-Bellido, A; Han, J; Hindrichs, O; Khukhunaishvili, A; Lo, K H; Tan, P; Verzetti, M; Ciesielski, R; Goulianos, K; Mesropian, C; Agapitos, A; Chou, J P; Gershtein, Y; Gómez Espinosa, T A; Halkiadakis, E; Heindl, M; Hughes, E; Kaplan, S; Kunnawalkam Elayavalli, R; Kyriacou, S; Lath, A; Montalvo, R; Nash, K; Osherson, M; Saka, H; Salur, S; Schnetzer, S; Sheffield, D; Somalwar, S; Stone, R; Thomas, S; Thomassen, P; Walker, M; Delannoy, A G; Heideman, J; Riley, G; Rose, K; Spanier, S; Thapa, K; Bouhali, O; Castaneda Hernandez, A; Celik, A; Dalchenko, M; De Mattia, M; Delgado, A; Dildick, S; Eusebi, R; Gilmore, J; Huang, T; Kamon, T; Mueller, R; Pakhotin, Y; Patel, R; Perloff, A; Perniè, L; Rathjens, D; Safonov, A; Tatarinov, A; Akchurin, N; Damgov, J; De Guio, F; Dudero, P R; Faulkner, J; Gurpinar, E; Kunori, S; Lamichhane, K; Lee, S W; Mengke, T; Muthumuni, S; Peltola, T; Undleeb, S; Volobouev, I; Wang, Z; Greene, S; Gurrola, A; Janjam, R; Johns, W; Maguire, C; Melo, A; Ni, H; Padeken, K; Ruiz Alvarez, J D; Sheldon, P; Tuo, S; Velkovska, J; Xu, Q; Arenton, M W; Barria, P; Cox, B; Hirosky, R; Joyce, M; Ledovskoy, A; Li, H; Neu, C; Sinthuprasith, T; Wang, Y; Wolfe, E; Xia, F; Harr, R; Karchin, P E; Poudyal, N; Sturdy, J; Thapa, P; Zaleski, S; Brodski, M; Buchanan, J; Caillol, C; Carlsmith, D; Dasu, S; Dodd, L; Duric, S; Gomber, B; Grothe, M; Herndon, M; Hervé, A; Hussain, U; Klabbers, P; Lanaro, A; Levine, A; Long, K; Loveless, R; Rekovic, V; Ruggles, T; Savin, A; Smith, N; Smith, W H; Woods, N
2018-05-18
A search for narrow resonances decaying to bottom quark-antiquark pairs is presented, using a data sample of proton-proton collisions at sqrt[s]=8 TeV corresponding to an integrated luminosity of 19.7 fb^{-1}. The search is extended to masses lower than those reached in typical searches for resonances decaying into jet pairs at the LHC, by taking advantage of triggers that identify jets originating from bottom quarks. No significant excess of events is observed above the background predictions. Limits are set on the product of cross section and branching fraction to bottom quarks for spin 0, 1, and 2 resonances in the mass range of 325-1200 GeV. These results improve on the limits for resonances decaying into jet pairs in the 325-500 GeV mass range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sirunyan, A. M.; Tumasyan, A.; Adam, W.
A search for narrow resonances decaying to bottom quark-antiquark pairs is presented, using a data sample of proton-proton collisions at s=8 TeV corresponding to an integrated luminosity of 19.7 fb -1. The search is extended to masses lower than those reached in typical searches for resonances decaying into jet pairs at the LHC, by taking advantage of triggers that identify jets originating from bottom quarks. No significant excess of events is observed above the background predictions. Limits are set on the product of cross section and branching fraction to bottom quarks for spin 0, 1, and 2 resonances in themore » mass range of 325–1200 GeV. These results improve on the limits for resonances decaying into jet pairs in the 325–500 GeV mass range.« less
Heat conduction in cooling flows. [in clusters of galaxies
NASA Technical Reports Server (NTRS)
Bregman, Joel N.; David, L. P.
1988-01-01
It has been suggested that electron conduction may significantly reduce the accretion rate (and star foramtion rate) for cooling flows in clusters of galaxies. A numerical hydrodynamics code was used to investigate the time behavior of cooling flows with conduction. The usual conduction coefficient is modified by an efficiency factor, mu, to realize the effects of tangled magnetic field lines. Two classes of models are considered, one where mu is independent of position and time, and one where inflow stretches the field lines and changes mu. In both cases, there is only a narrow range of initial conditions for mu in which the cluster accretion rate is reduced while a significant temperature gradient occurs. In the first case, no steady solution exists in which both conditions are met. In the second case, steady state solutions occur in which both conditions are met, but only for a narrow range of initial values where mu = 0.001.
NASA Technical Reports Server (NTRS)
Gorjian, V.; Cleary, K.; Werner, M. W.; Lawrence, C. R.
2007-01-01
We present a strong correlation between the [Ne v] 14.3 mm and [Ne III] 15.6 mm emission lines arising from the narrow-line regions (NLRs) of active galactic nuclei (AGNs), spanning 4 orders of magnitude in luminosity. The data are compiled primarily from Spitzer Space Telescope observations of nearby Seyfert galaxies (median z p 0.01) and 3C radio sources (median z p 0.52). This correlation is consistent with earlier studies in the optical/UV bands showing that line ratios arising in the NLRs are remarkably constant across AGNs. We also show that the correlation allows only a very narrow range in ionization parameter for simple photoionization models. The observed correlation will place tight constraints on alternative models, which predict constant line ratios over a broader range in ionization parameter.
Costion, Craig M; Kress, W John; Crayn, Darren M
2016-01-01
The taxonomic status of a single island, narrow range endemic plant species from Palau, Micronesia (Timonius salsedoi) was assessed using DNA barcode markers, additional plastid loci, and morphology in order to verify its conservation status. DNA barcode loci distinguished T. salsedoi from all other Timonius species sampled from Palau, and were supported by sequence data from the atpB-rbcL intergenic spacer region. Timonius salsedoi was only known from two mature individual trees in 2012. Due to its extremely narrow range and population size, it had previously been recommended to be listed as Critically Endangered Status under three separate IUCN Criteria. In 2014 a second survey of the population following a typhoon revealed that the only two known trees had died suggesting that this species may now be extinct. Comprehensive follow up surveys of suitable habitat for this species are urgently required.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hou, Huilong; Hamilton, Reginald F., E-mail: rfhamilton@psu.edu; Horn, Mark W.
NiTi shape memory alloy (SMA) thin films were fabricated using biased target ion beam deposition (BTIBD), which is a new technique for fabricating submicrometer-thick SMA thin films, and the capacity to exhibit shape memory behavior was investigated. The thermally induced shape memory effect (SME) was studied using the wafer curvature method to report the stress-temperature response. The films exhibited the SME in a temperature range above room temperature and a narrow thermal hysteresis with respect to previous reports. To confirm the underlying phase transformation, in situ x-ray diffraction was carried out in the corresponding phase transformation temperature range. The B2more » to R-phase martensitic transformation occurs, and the R-phase transformation is stable with respect to the expected conversion to the B19′ martensite phase. The narrow hysteresis and stable R-phase are rationalized in terms of the unique properties of the BTIBD technique.« less
Threshold-type dose response for induction of neoplastic transformation by 1 GeV/nucleon iron ions.
Elmore, E; Lao, X-Y; Kapadia, R; Redpath, J L
2009-06-01
Neoplastic transformation of HeLa x skin fibroblast human hybrid cells by doses of 1 GeV/nucleon iron ions in the range 1 cGy to 1 Gy to exposed cultures has been examined. The data indicate a threshold-type dose-response curve with no increase in transformation frequency until doses above 20 cGy. At doses <10 cGy, not all exposed cells receive a direct traversal of an iron-ion track core, but all exposed cells receive up to several mGy of low-LET radiation associated with the delta-ray penumbra. It is proposed that the threshold-type response seen is a consequence of an adaptive response associated with the delta-ray exposure. For comparison purposes, the dose response for (137)Cs gamma rays over the same dose range was examined using the same experimental procedure. As we have shown previously, the dose response for (137)Cs gamma radiation was J-shaped. The iron ions were 1.5 to 1.7 times more biologically effective than the gamma radiation over the dose range examined.
Marincek, Nicolas; Jörg, Ann-Catherine; Brunner, Philippe; Schindler, Christian; Koller, Michael T; Rochlitz, Christoph; Müller-Brand, Jan; Maecke, Helmut R; Briel, Matthias; Walter, Martin A
2013-01-15
We describe the long-term outcome after clinical introduction and dose escalation of somatostatin receptor targeted therapy with [90Y-DOTA]-TOC in patients with metastasized neuroendocrine tumors. In a clinical phase I dose escalation study we treated patients with increasing [90Y-DOTA]-TOC activities. Multivariable Cox regression and competing risk regression were used to compare efficacy and toxicities of the different dosage protocols. Overall, 359 patients were recruited; 60 patients were enrolled for low dose (median: 2.4 GBq/cycle, range 0.9-7.8 GBq/cycle), 77 patients were enrolled for intermediate dose (median: 3.3 GBq/cycle, range: 2.0-7.4 GBq/cycle) and 222 patients were enrolled for high dose (median: 6.7 GBq/cycle, range: 3.7-8.1 GBq/cycle) [90Y-DOTA]-TOC treatment. The incidences of hematotoxicities grade 1-4 were 65.0%, 64.9% and 74.8%; the incidences of grade 4/5 kidney toxicities were 8.4%, 6.5% and 14.0%, and the median survival was 39 (range: 1-158) months, 34 (range: 1-118) months and 29 (range: 1-113) months. The high dose protocol was associated with an increased risk of kidney toxicity (Hazard Ratio: 3.12 (1.13-8.59) vs. intermediate dose, p = 0.03) and a shorter overall survival (Hazard Ratio: 2.50 (1.08-5.79) vs. low dose, p = 0.03). Increasing [90Y-DOTA]-TOC activities may be associated with increasing hematological toxicities. The dose related hematotoxicity profile of [90Y-DOTA]-TOC could facilitate tailoring [90Y-DOTA]-TOC in patients with preexisting hematotoxicities. The results of the long-term outcome suggest that fractionated [90Y-DOTA]-TOC treatment might allow to reduce renal toxicity and to improve overall survival. (ClinicalTrials.gov number NCT00978211).
2013-01-01
Background We describe the long-term outcome after clinical introduction and dose escalation of somatostatin receptor targeted therapy with [90Y-DOTA]-TOC in patients with metastasized neuroendocrine tumors. Methods In a clinical phase I dose escalation study we treated patients with increasing [90Y-DOTA]-TOC activities. Multivariable Cox regression and competing risk regression were used to compare efficacy and toxicities of the different dosage protocols. Results Overall, 359 patients were recruited; 60 patients were enrolled for low dose (median: 2.4 GBq/cycle, range 0.9-7.8 GBq/cycle), 77 patients were enrolled for intermediate dose (median: 3.3 GBq/cycle, range: 2.0-7.4 GBq/cycle) and 222 patients were enrolled for high dose (median: 6.7 GBq/cycle, range: 3.7-8.1 GBq/cycle) [90Y-DOTA]-TOC treatment. The incidences of hematotoxicities grade 1–4 were 65.0%, 64.9% and 74.8%; the incidences of grade 4/5 kidney toxicities were 8.4%, 6.5% and 14.0%, and the median survival was 39 (range: 1–158) months, 34 (range: 1–118) months and 29 (range: 1–113) months. The high dose protocol was associated with an increased risk of kidney toxicity (Hazard Ratio: 3.12 (1.13-8.59) vs. intermediate dose, p = 0.03) and a shorter overall survival (Hazard Ratio: 2.50 (1.08-5.79) vs. low dose, p = 0.03). Conclusions Increasing [90Y-DOTA]-TOC activities may be associated with increasing hematological toxicities. The dose related hematotoxicity profile of [90Y-DOTA]-TOC could facilitate tailoring [90Y-DOTA]-TOC in patients with preexisting hematotoxicities. The results of the long-term outcome suggest that fractionated [90Y-DOTA]-TOC treatment might allow to reduce renal toxicity and to improve overall survival. Trial registration ClinicalTrials.gov number:NCT00978211 PMID:23320604
NASA Astrophysics Data System (ADS)
Kairn, T.; Crowe, S. B.; Charles, P. H.; Trapp, J. V.
2014-03-01
This study investigates the variation of photon field penumbra shape with initial electron beam diameter, for very narrow beams. A Varian Millenium MLC (Varian Medical Systems, Palo Alto, USA) and a Brainlab m3 microMLC (Brainlab AB. Feldkirchen, Germany) were used, with one Varian iX linear accelerator, to produce fields that were (nominally) 0.20 cm across. Dose profiles for these fields were measured using radiochromic film and compared with the results of simulations completed using BEAMnrc and DOSXYZnrc, where the initial electron beam was set to FWHM = 0.02, 0.10, 0.12, 0.15, 0.20 and 0.50 cm. Increasing the electron-beam FWHM produced increasing occlusion of the photon source by the closely spaced collimator leaves and resulted in blurring of the simulated profile widths from 0.24 to 0.58 cm, for the MLC, from 0.11 to 0.40 cm, for the microMLC. Comparison with measurement data suggested that the electron spot size in the clinical linear accelerator was between FWHM = 0.10 and 0.15 cm, encompassing the result of our previous output-factor based work, which identified a FWHM of 0.12 cm. Investigation of narrow-beam penumbra variation has been found to be a useful procedure, with results varying noticeably with linear accelerator spot size and allowing FWHM estimates obtained using other methods to be verified.
A photoacoustic tool for therapeutic drug monitoring of heparin (Conference Presentation)
NASA Astrophysics Data System (ADS)
Wang, Junxin; Hartanto, James; Jokerst, Jesse V.
2017-03-01
Heparin is used broadly in cardiac, pulmonary, surgical, and vascular medicine to treat thrombotic disorders with over 500 million doses per year globally. Despite this widespread use, it has a narrow therapeutic window and is one of the top three medication errors. The active partial thromboplastin time (PTT) monitors heparin, but this blood test suffers from long turnaround times, a variable reference range, and limited utility with low molecular weight heparin. Here, we describe an imaging technique that can monitor heparin concentration and activity in real time using photoacoustic spectroscopy via methylene blue as a simple and Federal Drug Agency-approved contrast agent. We found a strong correlation between heparin concentration and photoacoustic signal measured in phosphate buffered saline (PBS) and blood (R2>0.90). Clinically relevant concentrations were detected in blood with a heparin detection limit of 0.28 U/mL and a low molecular weight heparin (enoxaparin) detection limit of 72 μg/mL. We validated this imaging approach by correlation to the PTT (Pearson's r = 0.86; p<0.05) as well as with protamine sulfate treatment. To the best of our knowledge, this is the first report to use imaging data to monitor anticoagulation.
Pitt, Bertram; Garza, Dahlia
2018-05-01
Hyperkalemia (HK) occurs often among patients with chronic kidney disease (CKD) and heart failure (HF) and those treated with renin-angiotensin-aldosterone system inhibitors (RAASI). Even small deviations from normal potassium levels carry increased risk of mortality. Patiromer is approved for treatment of HK and has been shown in clinical trials to reduce serum potassium among patients with HK and comorbid conditions. Areas covered: We review pooled data from two clinical trials of patiromer in patients with CKD and HK, safety of patiromer in special populations, drug-drug interaction (DDI) studies, and other studies in healthy volunteers. Expert opinion: Potassium must be maintained within a narrow range to avoid increased risk of mortality. Patients with CKD and HF and those receiving RAASI require careful monitoring of potassium levels. Patiromer effectively reduces serum potassium, and gastrointestinal adverse events (AEs) are the most common patiromer-associated AEs. Effective management of HK with patiromer may allow use of RAASI at optimal doses as recommended by treatment guidelines. Future research should examine the potential for potassium binders, including patiromer, to extend use of RAASI in appropriate patient populations.
A novel method for computing effective diffusivity: Application to helium implanted α-Fe thin films
NASA Astrophysics Data System (ADS)
Dunn, Aaron; Agudo-Merida, Laura; Martin-Bragado, Ignacio; McPhie, Mathieu; Cherkaoui, Mohammed; Capolungo, Laurent
2014-05-01
The effective diffusivity of helium in thin iron films is quantified using spatially resolved stochastic cluster dynamics and object kinetic Monte Carlo simulations. The roles of total displacement dose (in DPA), damage rate, helium to DPA ratio, layer thickness, and damage type (cascade damage vs Frenkel pair implantation) on effective He diffusivity are investigated. Helium diffusivity is found to decrease with increasing total damage and decreasing damage rate. Arrhenius plots show strongly increased helium diffusivity at high temperatures, high total implantation, and low implantation rates due to decreased vacancy and vacancy cluster concentrations. At low temperatures, effective diffusivity is weakly dependent on foil thickness while at high temperatures, narrower foils prevent defect accumulation by releasing all defects at the free surfaces. Helium to DPA ratio is not shown to strongly change helium diffusivity in the range of irradiation conditions simulated. Frenkel pair implantation is shown to cause higher effective diffusivity and more complex diffusion mechanisms than cascade implantation. The results of these simulations indicate that the differences in damage rates between implantation experiments and fission or fusion environments may result in differences in the final microstructure.
NASA Astrophysics Data System (ADS)
Yu, Wen; Hallinen, Kelsey; Wood, Kevin
Enterococcus faecalis are commonly associated with hospital acquired infections, because they readily form biofilms on instruments and medical devices. Biofilms are inherently more resistant to killing by antibiotics compared to planktonic bacteria, in part because of their heterogeneous spatial structure. Surprisingly, however, subminimal inhibitory concentrations (sub-MICs) of some antibiotics can actually promote biofilm formation. Unfortunately, much is still unknown about how low drug doses affect the composition and spatial structure of the biofilm. In this work, we investigate the effects of sub-MICs of ampicillin on the formation of E. faecalis biofilms. First, we quantified biofilm mass using crystal violet staining in polystyrene microtiter plates. We found that total biofilm mass is increased over a narrow range of ampicillin concentrations before ultimately declining at higher concentrations. Second, we show that sub-MICs of ampicillin can increase mass of E. faecalis biofilms while simultaneously increasing extracellular DNA/RNA and changing total number of viable cells under confocal microscopy. Further, we use RNA-seq to identify genes differentially expressed under sub-MICs of ampicillin. Finally, we show a mathematical model to explain this phenomenon. This work was funded by The Hartwell Foundation Individual Biomedical Research Award and NSF CAREER 1553208 to KBW.
Issues of Commonality. Volume II. Issue Analysis.
1980-12-01
lubricating oil, and residual oil. 68 ° B Diesel fuel and kerosene make up what are known as the middle distillates. Jet fuels are blends from this...group of distillates which include some gasoline and some heavier oils. The range of hydrocarbons selected for this blending determines the "cut" of...the fuel. Wide-cut fuels are blended fram a wide range of hydrocarbons; narrow-cut fuels include only a small range of hydrocarbons from the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, J; Park, S; Kim, J
2016-06-15
Purpose: To investigate the effect of multi-leaf collimators (MLCs) with leaf width of 1.25 mm on the plan quality of volumetric modulated arc therapy (VMAT) for prostate cancer. Methods: A total of 20 patients with prostate cancer were retrospectively selected. Using a high definition MLC (HD MLC), primary and boost VMAT plans with two full arcs were generated for each patient (original plan). After that, by shifting patient CT images by 1.25 mm in the cranio-caudal direction between the 1st and the 2nd arc, we simulated fluences made with MLCs with leaf width of 1.25 mm. After shifting, primary andmore » boost plans were generated for each patient (shifted plan). A sum plan was generated by summation of the primary and boost plan for each patient. Dose-volumetric parameters were calculated and compared. Results: Both homogeneity index (HI) and conformity index (CI) of the shifted plans were better than those of the original plans in primary plans (HI = 0.044 vs. 0.040 with p < 0.001 and CI = 1.056 vs. 1.044 with p = 0.006). Similarly, the shifted plans for boost target volume showed better homogeneity and conformity than did the original plans (HI = 0.042 vs. 0.037 with p = 0.006 and CI = 1.015 vs. 1.009 with p < 0.001). The total body volumes of the original plans irradiated by the prescription dose were larger than those of the shifted plans in sum plans (60.9 cc vs. 49.0 cc with p = 0.007). Conclusion: Use of extremely narrow MLCs could increase dose homogeneity and conformity of the target volume for prostate VMAT. This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIP) (No. 2015R1C1A1A02036331).« less
NASA Astrophysics Data System (ADS)
Kwa, William
1998-11-01
In this thesis the dosimetric characteristics of asymmetric fields are investigated and a new computation method for the dosimetry of asymmetric fields is described and implemented into an existing treatment planning algorithm. Based on this asymmetric field treatment planning algorithm, the clinical use of asymmetric fields in cancer treatment is investigated, and new treatment techniques for conformal therapy are developed. Dose calculation is verified with thermoluminescent dosimeters in a body phantom. In this thesis, an analytical approach is proposed to account for the dose reduction when a corresponding symmetric field is collimated asymmetrically to a smaller asymmetric field. This is represented by a correction factor that uses the ratio of the equivalent field dose contributions between the asymmetric and symmetric fields. The same equation used in the expression of the correction factor can be used for a wide range of asymmetric field sizes, photon energies and linear accelerators. This correction factor will account for the reduction in scatter contributions within an asymmetric field, resulting in the dose profile of an asymmetric field resembling that of a wedged field. The output factors of some linear accelerators are dependent on the collimator settings and whether the upper or lower collimators are used to set the narrower dimension of a radiation field. In addition to this collimator exchange effect for symmetric fields, asymmetric fields are also found to exhibit some asymmetric collimator backscatter effect. The proposed correction factor is extended to account for these effects. A set of correction factors determined semi-empirically to account for the dose reduction in the penumbral region and outside the radiated field is established. Since these correction factors rely only on the output factors and the tissue maximum ratios, they can easily be implemented into an existing treatment planning system. There is no need to store either additional sets of asymmetric field profiles or databases for the implementation of these correction factors into an existing in-house treatment planning system. With this asymmetric field algorithm, the computation time is found to be 20 times faster than a commercial system. This computation method can also be generalized to the dose representation of a two-fold asymmetric field whereby both the field width and length are set asymmetrically, and the calculations are not limited to points lying on one of the principal planes. The dosimetric consequences of asymmetric fields on the dose delivery in clinical situations are investigated. Examples of the clinical use of asymmetric fields are given and the potential use of asymmetric fields in conformal therapy is demonstrated. An alternative head and neck conformal therapy is described, and the treatment plan is compared to the conventional technique. The dose distributions calculated for the standard and alternative techniques are confirmed with thermoluminescent dosimeters in a body phantom at selected dose points. (Abstract shortened by UMI.)
Blanco-Pastor, J L; Fernández-Mazuecos, M; Vargas, P
2013-08-01
Anthropogenic global climate change is expected to cause severe range contractions among alpine plants. Alpine areas in the Mediterranean region are of special concern because of the high abundance of endemic species with narrow ranges. This study combined species distribution models, population structure analyses and Bayesian skyline plots to trace the past and future distribution and diversity of Linaria glacialis, an endangered narrow endemic species that inhabits summits of Sierra Nevada (Spain). The results showed that: (i) the habitat of this alpine-Mediterranean species in Sierra Nevada suffered little changes during glacial and interglacial stages of late Quaternary; (ii) climatic oscillations in the last millennium (Medieval Warm Period and Little Ice Age) moderately affected the demographic trends of L. glacialis; (iii) future warming conditions will cause severe range contractions; and (iv) genetic diversity will not diminish at the same pace as the distribution range. As a consequence of the low population structure of this species, genetic impoverishment in the alpine zones of Sierra Nevada should be limited during range contraction. We conclude that maintenance of large effective population sizes via high mutation rates and high levels of gene flow may promote the resilience of alpine plant species when confronted with global warming. © 2013 John Wiley & Sons Ltd.
Radiation sensitivity and EPR dosimetric potential of gallic acid and its esters
NASA Astrophysics Data System (ADS)
Tuner, Hasan; Oktay Bal, M.; Polat, Mustafa
2015-02-01
In the preset work the radiation sensitivities of Gallic Acid anhydrous and monohydrate, Octyl, Lauryl, and Ethyl Gallate (GA, GAm, OG, LG, and EG) were investigated in the intermediate (0.5-20 kGy) and low radiation (<10 Gy) dose range using Electron Paramagnetic Resonance (EPR) spectroscopy. While OG, LG, and EG are presented a singlet EPR spectra, their radiation sensitivity found to be very different in the intermediate dose range. At low radiation dose range (<10 Gy) only LG is found to be present a signal that easily distinguished from the noise signals. The intermediate and low dose range radiation sensitivities are compared using well known EPR dosimeter alanine. The radiation yields (G) of the interested material were found to be 1.34×10-2, 1.48×10-2, 4.14×10-2, and 6.03×10-2, 9.44×10-2 for EG, GA, GAm, OG, and LG, respectively at the intermediate dose range. It is found that the simple EPR spectra and the noticeable EPR signal of LG make it a promising dosimetric material to be used below 10 Gy of radiation dose.
SparseCT: interrupted-beam acquisition and sparse reconstruction for radiation dose reduction
NASA Astrophysics Data System (ADS)
Koesters, Thomas; Knoll, Florian; Sodickson, Aaron; Sodickson, Daniel K.; Otazo, Ricardo
2017-03-01
State-of-the-art low-dose CT methods reduce the x-ray tube current and use iterative reconstruction methods to denoise the resulting images. However, due to compromises between denoising and image quality, only moderate dose reductions up to 30-40% are accepted in clinical practice. An alternative approach is to reduce the number of x-ray projections and use compressed sensing to reconstruct the full-tube-current undersampled data. This idea was recognized in the early days of compressed sensing and proposals for CT dose reduction appeared soon afterwards. However, no practical means of undersampling has yet been demonstrated in the challenging environment of a rapidly rotating CT gantry. In this work, we propose a moving multislit collimator as a practical incoherent undersampling scheme for compressed sensing CT and evaluate its application for radiation dose reduction. The proposed collimator is composed of narrow slits and moves linearly along the slice dimension (z), to interrupt the incident beam in different slices for each x-ray tube angle (θ). The reduced projection dataset is then reconstructed using a sparse approach, where 3D image gradients are employed to enforce sparsity. The effects of the collimator slits on the beam profile were measured and represented as a continuous slice profile. SparseCT was tested using retrospective undersampling and compared against commercial current-reduction techniques on phantoms and in vivo studies. Initial results suggest that SparseCT may enable higher performance than current-reduction, particularly for high dose reduction factors.
Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models.
Tian, Xiaoyu; Li, Xiang; Segars, W Paul; Frush, Donald P; Paulson, Erik K; Samei, Ehsan
2013-12-21
Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDI(vol)-normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2-180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2-80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57-180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDI(vol)-normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDIvol/DLP values may be used to estimate organ dose, effective dose, and risk index in abdominopelvic CT based on the coefficients derived from a large population of pediatric and adult patients.
Feasibility of RACT for 3D dose measurement and range verification in a water phantom.
Alsanea, Fahed; Moskvin, Vadim; Stantz, Keith M
2015-02-01
The objective of this study is to establish the feasibility of using radiation-induced acoustics to measure the range and Bragg peak dose from a pulsed proton beam. Simulation studies implementing a prototype scanner design based on computed tomographic methods were performed to investigate the sensitivity to proton range and integral dose. Derived from thermodynamic wave equation, the pressure signals generated from the dose deposited from a pulsed proton beam with a 1 cm lateral beam width and a range of 16, 20, and 27 cm in water using Monte Carlo methods were simulated. The resulting dosimetric images were reconstructed implementing a 3D filtered backprojection algorithm and the pressure signals acquired from a 71-transducer array with a cylindrical geometry (30 × 40 cm) rotated over 2π about its central axis. Dependencies on the detector bandwidth and proton beam pulse width were performed, after which, different noise levels were added to the detector signals (using 1 μs pulse width and a 0.5 MHz cutoff frequency/hydrophone) to investigate the statistical and systematic errors in the proton range (at 20 cm) and Bragg peak dose (of 1 cGy). The reconstructed radioacoustic computed tomographic image intensity was shown to be linearly correlated to the dose within the Bragg peak. And, based on noise dependent studies, a detector sensitivity of 38 mPa was necessary to determine the proton range to within 1.0 mm (full-width at half-maximum) (systematic error < 150 μm) for a 1 cGy Bragg peak dose, where the integral dose within the Bragg peak was measured to within 2%. For existing hydrophone detector sensitivities, a Bragg peak dose of 1.6 cGy is possible. This study demonstrates that computed tomographic scanner based on ionizing radiation-induced acoustics can be used to verify dose distribution and proton range with centi-Gray sensitivity. Realizing this technology into the clinic has the potential to significantly impact beam commissioning, treatment verification during particle beam therapy and image guided techniques.
Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models
NASA Astrophysics Data System (ADS)
Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Frush, Donald P.; Paulson, Erik K.; Samei, Ehsan
2013-12-01
Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDIvol-normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2-180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2-80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57-180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDIvol-normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDIvol/DLP values may be used to estimate organ dose, effective dose, and risk index in abdominopelvic CT based on the coefficients derived from a large population of pediatric and adult patients.
DSC studies on gamma irradiated poly(vinylidene fluoride) applied to high gamma dose dosimetry
NASA Astrophysics Data System (ADS)
Batista, Adriana S. M.; Faria, Luiz O.
2017-11-01
Poly(vinylidene fluoride) homopolymer (PVDF) was investigated for use on high gamma dose dosimetry. Samples were irradiated with gamma doses ranging from 100 kGy to 3000 kGy. Differential scanning calorimetry (DSC) was used to construct an unambiguous relationship between the melting transition latent heat (LM) and the absorbed dose (D). DSC thermograms were taken immediately, 1, 2 and 8 months after the irradiation process revealing that the LMx D relationship presented no change for doses ranging from 100 to 2750 kGy. FTIR and UV-Vis spectroscopy data revealed the radio-induction of C˭O and C˭C bonds. These radio-induced bonds were responsible by the chain stiffening and chain oxidation, respectively. SEM microscopy demonstrates that the spherulitic large crystalline structures present in pristine PVDF are destroyed with doses as low as 100 kGy. The DRX analysis revealed that the main effect of high gamma doses in the crystalline structure of PVDF is to provoke a change from the pristine PVDF α-phase to the γ-phase. Both the ability to detect gamma doses in a large dose range and the low fading features make PVDF homopolymers good candidates to be investigated as high gamma dose dosimeters.
Papadopoulou, D; Yakoumakis, Em; Sandilos, P; Thanopoulos, V; Makri, Tr; Gialousis, G; Houndas, D; Yakoumakis, N; Georgiou, Ev
2005-01-01
The purpose of this study was to estimate the radiation exposure of children, during cardiac catheterisations for the diagnosis or treatment of congenital heart disease. Radiation doses were estimated for 45 children aged from 1 d to 13 y old. Thermoluminescent dosemeters (TLDs) were used to estimate the posterior entrance dose (DP), the lateral entrance dose (DLAT), the thyroid dose and the gonads dose. A dose-area product (DAP) meter was also attached externally to the tube of the angiographic system and gave a direct value in mGy cm2 for each procedure. Posterior and lateral entrance dose values during cardiac catheterisations ranged from 1 to 197 mGy and from 1.1 to 250.3 mGy, respectively. Radiation exposure to the thyroid and the gonads ranged from 0.3 to 8.4 mGy to 0.1 and 0.7 mGy, respectively. Finally, the DAP meter values ranged between 360 and 33,200 mGy cm2. Radiation doses measured in this study are comparable with those reported to previous studies. Moreover, strong correlation was found between the DAP values and the entrance radiation dose measured with TLDs.
2011-05-01
for the research in the next year. The aims in the next year include further develop- ment of the prior image- based , narrowly collimated CBCT imaging...further investigation planned for the next year. 5 BODY 1 Research Accomplishments 1.1 Implement narrow beam collimation for CBCT ROI imaging I have...noise level to mimic different mAs used in clinical and research modes of the CBCT system. Based upon experiences with the numerical phantom, I designed
Narrow-Host-Range Bacteriophages That Infect Rhizobium etli Associate with Distinct Genomic Types
Santamaría, Rosa Isela; Bustos, Patricia; Sepúlveda-Robles, Omar; Lozano, Luis; Rodríguez, César; Fernández, José Luis; Juárez, Soledad; Kameyama, Luis; Guarneros, Gabriel; Dávila, Guillermo
2014-01-01
In this work, we isolated and characterized 14 bacteriophages that infect Rhizobium etli. They were obtained from rhizosphere soil of bean plants from agricultural lands in Mexico using an enrichment method. The host range of these phages was narrow but variable within a collection of 48 R. etli strains. We obtained the complete genome sequence of nine phages. Four phages were resistant to several restriction enzymes and in vivo cloning, probably due to nucleotide modifications. The genome size of the sequenced phages varied from 43 kb to 115 kb, with a median size of ∼45 to 50 kb. A large proportion of open reading frames of these phage genomes (65 to 70%) consisted of hypothetical and orphan genes. The remainder encoded proteins needed for phage morphogenesis and DNA synthesis and processing, among other functions, and a minor percentage represented genes of bacterial origin. We classified these phages into four genomic types on the basis of their genomic similarity, gene content, and host range. Since there are no reports of similar sequences, we propose that these bacteriophages correspond to novel species. PMID:24185856
Amplitude equation and long-range interactions in underwater sand ripples in one dimension
NASA Astrophysics Data System (ADS)
Schnipper, Teis; Mertens, Keith; Ellegaard, Clive; Bohr, Tomas
2008-10-01
We present an amplitude equation for sand ripples under oscillatory flow in a situation where the sand is moving in a narrow channel and the height profile is practically one dimensional. The equation has the form ht=-γ(h- hmacr )+((hx)2-1)hxx-hxxxx+δ((hx)2)xx which, due to the first term, is neither completely local (it has long-range coupling through the average height hmacr ) nor has local sand conservation. We argue that this is reasonable and show that the equation compares well with experimental observations in narrow channels. We focus in particular on the so-called doubling transition, a secondary instability caused by the sudden decrease in the amplitude of the water motion, leading to the appearance of a new ripple in each trough. This transition is well reproduced for sufficiently large δ (asymmetry between trough and crest). We finally present surprising experimental results showing that long-range coupling is indeed seen in the initial details of the doubling transition, where in fact two small ripples are initially formed, followed by global symmetry breaking removing one of them.
Flying and swimming animals cruise at a Strouhal number tuned for high power efficiency.
Taylor, Graham K; Nudds, Robert L; Thomas, Adrian L R
2003-10-16
Dimensionless numbers are important in biomechanics because their constancy can imply dynamic similarity between systems, despite possible differences in medium or scale. A dimensionless parameter that describes the tail or wing kinematics of swimming and flying animals is the Strouhal number, St = fA/U, which divides stroke frequency (f) and amplitude (A) by forward speed (U). St is known to govern a well-defined series of vortex growth and shedding regimes for airfoils undergoing pitching and heaving motions. Propulsive efficiency is high over a narrow range of St and usually peaks within the interval 0.2 < St < 0.4 (refs 3-8). Because natural selection is likely to tune animals for high propulsive efficiency, we expect it to constrain the range of St that animals use. This seems to be true for dolphins, sharks and bony fish, which swim at 0.2 < St < 0.4. Here we show that birds, bats and insects also converge on the same narrow range of St, but only when cruising. Tuning cruise kinematics to optimize St therefore seems to be a general principle of oscillatory lift-based propulsion.
Narrow bandpass steep edge optical filter for the JAST/T80 telescope instrumentation
NASA Astrophysics Data System (ADS)
Reichel, S.; Brauneck, U.; Bourquin, S.; Marín-Franch, A.
2013-09-01
The Observatorio Astrofisico de Javalambre in Spain observes with its JAST/T80 telescope galaxies in the Local Universe in a systematic study. This is accomplished with a multi-band photometric all sky survey called Javalambre Photometric Local Universe Survey (J-PLUS). A wide field camera receives the signals from universe via optical filters. In this presentation the development and design of a narrow bandpass steep edge filter with wide suppression will be shown. The filter has a full width half maximum in the range of 13-15 nm (with <1 nm tolerance) with central wavelengths in the range 350-860nm and an average transmission larger than 90% in the passband. Signals beyond the passband (blocking range) have to be suppressed down to 250nm and up to 1050nm (spectral regime), where a blocking of OD 5 (transmission < 10-5) is required. The edges have to be steep for a small transition width from 5% to 80%. The spectral requirements result in a large number of layers which are deposited with magnetron sputtering. The transmitted wavefront error of the optical filter must be less than lambda/2 over the 100mm aperture and the central wavelength uniformity must be better than +/- 0.4% over the clear aperture. The filter consists of optical filter glass and a coated substrate in order to reach the spectral requirements. The substrate is coated with more than 120 layers. The total filter thickness was specified to be 8.0mm. Results of steep edge narrow bandpass filters will be demonstrated fulfilling all these demanding requirements.
Matsuda, Osamu; Hara, Masashi; Tobita, Hiroyuki; Yazaki, Kenichi; Nakagawa, Toshinori; Shimizu, Kuniyoshi; Uemura, Akira; Utsugi, Hajime
2015-01-01
Regeneration of planted forests of Cryptomeria japonica (sugi) and Chamaecyparis obtuse (hinoki) is the pressing importance to the forest administration in Japan. Low seed germination rate of these species, however, has hampered low-cost production of their seedlings for reforestation. The primary cause of the low germinability has been attributed to highly frequent formation of anatomically unsound seeds, which are indistinguishable from sound germinable seeds by visible observation and other common criteria such as size and weight. To establish a method for sound seed selection in these species, hyperspectral imaging technique was used to identify a wavelength range where reflectance spectra differ clearly between sound and unsound seeds. In sound seeds of both species, reflectance in a narrow waveband centered at 1,730 nm, corresponding to a lipid absorption band in the short-wavelength infrared (SWIR) range, was greatly depressed relative to that in adjacent wavebands on either side. Such depression was absent or less prominent in unsound seeds. Based on these observations, a reflectance index SQI, abbreviated for seed quality index, was formulated using reflectance at three narrow SWIR wavebands so that it represents the extent of the depression. SQI calculated from seed area-averaged reflectance spectra and spatial distribution patterns of pixelwise SQI within each seed area were both proven as reliable criteria for sound seed selection. Enrichment of sound seeds was accompanied by an increase in germination rate of the seed lot. Thus, the methods described are readily applicable toward low-cost seedling production in combination with single seed sowing technology. PMID:26083366
What we need to know about the effect of lithium on the kidney.
Gong, Rujun; Wang, Pei; Dworkin, Lance
2016-12-01
Lithium has been a valuable treatment for bipolar affective disorders for decades. Clinical use of lithium, however, has been problematic due to its narrow therapeutic index and concerns for its toxicity in various organ systems. Renal side effects associated with lithium include polyuria, nephrogenic diabetes insipidus, proteinuria, distal renal tubular acidosis, and reduction in glomerular filtration rate. Histologically, chronic lithium nephrotoxicity is characterized by interstitial nephritis with microcyst formation and occasional focal segmental glomerulosclerosis. Nevertheless, this type of toxicity is uncommon, with the strongest risk factors being high serum levels of lithium and longer time on lithium therapy. In contrast, in experimental models of acute kidney injury and glomerular disease, lithium has antiproteinuric, kidney protective, and reparative effects. This paradox may be partially explained by lower lithium doses and short duration of therapy. While long-term exposure to higher psychiatric doses of lithium may be nephrotoxic, short-term low dose of lithium may be beneficial and ameliorate kidney and podocyte injury. Mechanistically, lithium targets glycogen synthase kinase-3β, a ubiquitously expressed serine/threonine protein kinase implicated in the processes of tissue injury, repair, and regeneration in multiple organ systems, including the kidney. Future studies are warranted to discover the exact "kidney-protective dose" of lithium and test the effects of low-dose lithium on acute and chronic kidney disease in humans. Copyright © 2016 the American Physiological Society.
van den Heuvel, Maria Elisabeth Nicoletta; van Zanten, Henriette A; Bachman, Tom E; Te Pas, Arjan B; van Kaam, Anton H; Onland, Wes
2018-06-01
To investigate the effect of different pulse oximetry (SpO 2 ) target range settings during automated fraction of inspired oxygen control (A-FiO 2 ) on time spent within a clinically set SpO 2 alarm range in oxygen-dependent infants on noninvasive respiratory support. Forty-one preterm infants (gestational age [median] 26 weeks, age [median] 21 days) on FiO 2 >0.21 receiving noninvasive respiratory support were subjected to A-FiO 2 using 3 SpO 2 target ranges (86%-94%, 88%-92%, or 89%-91%) in random order for 24 hours each. Before switching to the next target range, SpO 2 was manually controlled for 24 hours (washout period). The primary outcome was the time spent within the clinically set alarm limits of 86%-94%. The percent time within the 86%-94% SpO 2 alarm range was similar for all 3 A-FiO 2 target ranges (74%). Time spent in hyperoxemia was not significantly different between target ranges. However, the time spent in severe hypoxemia (SpO 2 <80%) was significantly reduced during the narrowed target ranges of A-FiO 2 (88%-92%; 1.9%, 89%-91%; 1.7%) compared with the wide target range (86%-94%; 3.4%, P < .001). There were no differences between the 88%-92% and 89-91% target range. Narrowing the target range of A-FiO 2 to the desired median ±2% is effective in reducing the time spent in hypoxemia, without increasing the risk of hyperoxemia. www.trialregister.nl: NTR4368. Copyright © 2018 Elsevier Inc. All rights reserved.
Radiation dose reduction in parasinus CT by spectral shaping.
May, Matthias S; Brand, Michael; Lell, Michael M; Sedlmair, Martin; Allmendinger, Thomas; Uder, Michael; Wuest, Wolfgang
2017-02-01
Spectral shaping aims to narrow the X-ray spectrum of clinical CT. The aim of this study was to determine the image quality and the extent of radiation dose reduction that can be achieved by tin prefiltration for parasinus CT. All scans were performed with a third generation dual-source CT scanner. A study protocol was designed using 100 kV tube voltage with tin prefiltration (200 mAs) that provides image noise levels comparable to a low-dose reference protocol using 100 kV without spectral shaping (25 mAs). One hundred consecutive patients were prospectively enrolled and randomly assigned to the study or control group. All patients signed written informed consent. The study protocol was approved by the local Institutional Review Board and applies to the HIPAA. Subjective and objective image quality (attenuation values, image noise, and contrast-to-noise ratio (CNR)) were assessed. Radiation exposure was assessed as volumetric CT dose index, and effective dose was estimated. Mann-Whitney U test was performed for radiation exposure and for image noise comparison. All scans were of diagnostic image quality. Image noise in air, in the retrobulbar fat, and in the eye globe was comparable between both groups (all p > 0.05). CNR eye globe/air did not differ significantly between both groups (p = 0.7). Radiation exposure (1.7 vs. 2.1 mGy, p < 0.01) and effective dose (0.055 vs. 0.066 mSv, p < 0.01) were significantly reduced in the study group. Radiation dose can be further reduced by 17% for low-dose parasinus CT by tin prefiltration maintaining diagnostic image quality.
The effects of phototherapy and melanocytes on keratinocytes
Tang, Luyan; Wu, Wenyu; Fu, Wenwen; Hu, Yao
2018-01-01
Phototherapy is widely used in the treatment of vitiligo. Previous studies have focused on the effects of ultraviolet (UV) radiation on melanocytes; however, the biological effects of phototherapy and melanocytes on keratinocytes remain to be elucidated. To investigate and assess the effects of clinically doses of broad band (BB)-UVA, narrow band (NB)-UVB and melanocytes on human keratinocytes in vitro, clinical doses of BB-UVA or NB-UVB radiation and human melanoma cell A375 co-culture were performed as stress divisors to HaCaT cells. Cell proliferation, expression of protease-activated receptor-2 (PAR-2) and nuclear factor E2-related factor 2 mRNA, lipid peroxidation and intracellular antioxidant level of keratinocytes were analyzed. It was demonstrated that UV radiation inhibited the proliferation of cells apart from following exposure to low dose (1 J/cm2) UVA. Medium dose (5 J/cm2) UVA radiation had no adverse effects on lipid peroxidation and increased antioxidant levels in HaCaT cells. Medium (200 mJ/cm2) and high (400 mJ/cm2) doses of UVB radiation induced cellular damage due to increased lipid peroxidation as indicated by levels of malondialdehyde. Furthermore, A375 co-culture treatment induced a similar effect on the lipid peroxidation of HaCaT as with low dose UVB radiation. Therefore, the results of the present study determined that clinical doses of BB-UVA and NB-UVB radiation had varying effects on proliferation and related protein levels in HaCaT cells. Co-culture with A375 had similar effects as those of low dose UVA and UVB radiation, in which the PAR-2 expression was significantly upregulated. PMID:29545869
Sizes of particles formed during municipal wastewater treatment.
Lech, Smoczynski; Marta, Kosobucka; Michal, Smoczynski; Harsha, Ratnaweera; Krystyna, Pieczulis-Smoczynska
2017-02-01
Volumetric diameters Dv and specific surface area SpS of sludge particles formed during chemical coagulation and electrocoagulation of sewage were determined. The obtained aggregate-flocs differed substantially in both Dv and SpS values. The differences in Dv and SpS values of the analyzed particles were interpreted based on theoretical models for expanding aggregates. The most uniform particles were formed under exposure to: (a) optimal and maximal doses of PIX, (b) optimal doses of PAX, (c) maximal doses of the Al electro-coagulant. The lowest PIX dose produced the least uniform particles. Sludge aggregates-particles produced under exposure to minimal doses of PIX and the Al electro-coagulant were characterized by the lowest SpS values. Sludge particles coagulated by PAX and the particles formed at higher doses of PIX and the Al electro-coagulant had higher SpS values. The particles formed at all doses of the applied coagulants and electro-coagulants were generally classified into two size ranges: the main range and the secondary range. Most particles belonged to the main size range. An increase in the percentage of colloidal hydroxide particles in sewage sludge increased SpS.
NASA Astrophysics Data System (ADS)
Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Asilar, E.; Bergauer, T.; Brandstetter, J.; Brondolin, E.; Dragicevic, M.; Erö, J.; Flechl, M.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Hartl, C.; Hörmann, N.; Hrubec, J.; Jeitler, M.; König, A.; Krätschmer, I.; Liko, D.; Matsushita, T.; Mikulec, I.; Rabady, D.; Rad, N.; Rahbaran, B.; Rohringer, H.; Schieck, J.; Strauss, J.; Treberer-Treberspurg, W.; Waltenberger, W.; Wulz, C.-E.; Mossolov, V.; Shumeiko, N.; Suarez Gonzalez, J.; Alderweireldt, S.; De Wolf, E. A.; Janssen, X.; Knutsson, A.; Lauwers, J.; Van De Klundert, M.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Van Spilbeeck, A.; Abu Zeid, S.; Blekman, F.; D'Hondt, J.; Daci, N.; De Bruyn, I.; Deroover, K.; Heracleous, N.; Lowette, S.; Moortgat, S.; Moreels, L.; Olbrechts, A.; Python, Q.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Parijs, I.; Brun, H.; Caillol, C.; Clerbaux, B.; De Lentdecker, G.; Delannoy, H.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Karapostoli, G.; Lenzi, T.; Léonard, A.; Luetic, J.; Maerschalk, T.; Marinov, A.; Randle-conde, A.; Seva, T.; Vander Velde, C.; Vanlaer, P.; Yonamine, R.; Zenoni, F.; Zhang, F.; Cimmino, A.; Cornelis, T.; Dobur, D.; Fagot, A.; Garcia, G.; Gul, M.; Mccartin, J.; Poyraz, D.; Salva, S.; Schöfbeck, R.; Tytgat, M.; Van Driessche, W.; Yazgan, E.; Zaganidis, N.; Beluffi, C.; Bondu, O.; Brochet, S.; Bruno, G.; Caudron, A.; Ceard, L.; De Visscher, S.; Delaere, C.; Delcourt, M.; Forthomme, L.; Francois, B.; Giammanco, A.; Jafari, A.; Jez, P.; Komm, M.; Lemaitre, V.; Magitteri, A.; Mertens, A.; Musich, M.; Nuttens, C.; Piotrzkowski, K.; Quertenmont, L.; Selvaggi, M.; Vidal Marono, M.; Wertz, S.; Beliy, N.; Aldá Júnior, W. L.; Alves, F. L.; Alves, G. A.; Brito, L.; Correa Martins Junior, M.; Hensel, C.; Moraes, A.; Pol, M. E.; Rebello Teles, P.; Belchior Batista Das Chagas, E.; Carvalho, W.; Chinellato, J.; Custódio, A.; Da Costa, E. M.; Da Silveira, G. G.; De Jesus Damiao, D.; De Oliveira Martins, C.; Fonseca De Souza, S.; Huertas Guativa, L. M.; Malbouisson, H.; Matos Figueiredo, D.; Mora Herrera, C.; Mundim, L.; Nogima, H.; Prado Da Silva, W. L.; Santoro, A.; Sznajder, A.; Tonelli Manganote, E. J.; Vilela Pereira, A.; Ahuja, S.; Bernardes, C. A.; Dogra, S.; Fernandez Perez Tomei, T. R.; Gregores, E. M.; Mercadante, P. G.; Moon, C. S.; Novaes, S. F.; Padula, Sandra S.; Romero Abad, D.; Ruiz Vargas, J. C.; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Rodozov, M.; Stoykova, S.; Sultanov, G.; Vutova, M.; Dimitrov, A.; Glushkov, I.; Litov, L.; Pavlov, B.; Petkov, P.; Fang, W.; Ahmad, M.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Chen, Y.; Cheng, T.; Du, R.; Jiang, C. H.; Leggat, D.; Liu, Z.; Romeo, F.; Shaheen, S. M.; Spiezia, A.; Tao, J.; Wang, C.; Wang, Z.; Zhang, H.; Zhao, J.; Asawatangtrakuldee, C.; Ban, Y.; Li, Q.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Avila, C.; Cabrera, A.; Chaparro Sierra, L. F.; Florez, C.; Gomez, J. P.; González Hernández, C. F.; Ruiz Alvarez, J. D.; Sanabria, J. C.; Godinovic, N.; Lelas, D.; Puljak, I.; Ribeiro Cipriano, P. M.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Ferencek, D.; Kadija, K.; Micanovic, S.; Sudic, L.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Finger, M.; Finger, M.; Carrera Jarrin, E.; Elgammal, S.; Mohamed, A.; Mohammed, Y.; Salama, E.; Calpas, B.; Kadastik, M.; Murumaa, M.; Perrini, L.; Raidal, M.; Tiko, A.; Veelken, C.; Eerola, P.; Pekkanen, J.; Voutilainen, M.; Härkönen, J.; Karimäki, V.; Kinnunen, R.; Lampén, T.; Lassila-Perini, K.; Lehti, S.; Lindén, T.; Luukka, P.; Peltola, T.; Tuominiemi, J.; Tuovinen, E.; Wendland, L.; Talvitie, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Fabbro, B.; Faure, J. L.; Favaro, C.; Ferri, F.; Ganjour, S.; Ghosh, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Kucher, I.; Locci, E.; Machet, M.; Malcles, J.; Rander, J.; Rosowsky, A.; Titov, M.; Zghiche, A.; Abdulsalam, A.; Antropov, I.; Baffioni, S.; Beaudette, F.; Busson, P.; Cadamuro, L.; Chapon, E.; Charlot, C.; Davignon, O.; Granier de Cassagnac, R.; Jo, M.; Lisniak, S.; Miné, P.; Naranjo, I. N.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Pigard, P.; Regnard, S.; Salerno, R.; Sirois, Y.; Strebler, T.; Yilmaz, Y.; Zabi, A.; Agram, J.-L.; Andrea, J.; Aubin, A.; Bloch, D.; Brom, J.-M.; Buttignol, M.; Chabert, E. C.; Chanon, N.; Collard, C.; Conte, E.; Coubez, X.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Le Bihan, A.-C.; Merlin, J. A.; Skovpen, K.; Van Hove, P.; Gadrat, S.; Beauceron, S.; Bernet, C.; Boudoul, G.; Bouvier, E.; Carrillo Montoya, C. A.; Chierici, R.; Contardo, D.; Courbon, B.; Depasse, P.; El Mamouni, H.; Fan, J.; Fay, J.; Gascon, S.; Gouzevitch, M.; Grenier, G.; Ille, B.; Lagarde, F.; Laktineh, I. B.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Popov, A.; Sabes, D.; Sordini, V.; Vander Donckt, M.; Verdier, P.; Viret, S.; Toriashvili, T.; Lomidze, D.; Autermann, C.; Beranek, S.; Feld, L.; Heister, A.; Kiesel, M. K.; Klein, K.; Lipinski, M.; Ostapchuk, A.; Preuten, M.; Raupach, F.; Schael, S.; Schomakers, C.; Schulte, J. F.; Schulz, J.; Verlage, T.; Weber, H.; Zhukov, V.; Brodski, M.; Dietz-Laursonn, E.; Duchardt, D.; Endres, M.; Erdmann, M.; Erdweg, S.; Esch, T.; Fischer, R.; Güth, A.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Knutzen, S.; Merschmeyer, M.; Meyer, A.; Millet, P.; Mukherjee, S.; Olschewski, M.; Padeken, K.; Papacz, P.; Pook, T.; Radziej, M.; Reithler, H.; Rieger, M.; Scheuch, F.; Sonnenschein, L.; Teyssier, D.; Thüer, S.; Cherepanov, V.; Erdogan, Y.; Flügge, G.; Hoehle, F.; Kargoll, B.; Kress, T.; Künsken, A.; Lingemann, J.; Nehrkorn, A.; Nowack, A.; Nugent, I. M.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Asin, I.; Beernaert, K.; Behnke, O.; Behrens, U.; Bin Anuar, A. A.; Borras, K.; Campbell, A.; Connor, P.; Contreras-Campana, C.; Costanza, F.; Diez Pardos, C.; Dolinska, G.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Gallo, E.; Garay Garcia, J.; Geiser, A.; Gizhko, A.; Grados Luyando, J. M.; Gunnellini, P.; Harb, A.; Hauk, J.; Hempel, M.; Jung, H.; Kalogeropoulos, A.; Karacheban, O.; Kasemann, M.; Keaveney, J.; Kieseler, J.; Kleinwort, C.; Korol, I.; Lange, W.; Lelek, A.; Leonard, J.; Lipka, K.; Lobanov, A.; Lohmann, W.; Mankel, R.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Mittag, G.; Mnich, J.; Mussgiller, A.; Ntomari, E.; Pitzl, D.; Placakyte, R.; Raspereza, A.; Roland, B.; Sahin, M. Ö.; Saxena, P.; Schoerner-Sadenius, T.; Seitz, C.; Spannagel, S.; Stefaniuk, N.; Trippkewitz, K. D.; Van Onsem, G. P.; Walsh, R.; Wissing, C.; Blobel, V.; Centis Vignali, M.; Draeger, A. R.; Dreyer, T.; Erfle, J.; Garutti, E.; Goebel, K.; Gonzalez, D.; Görner, M.; Haller, J.; Hoffmann, M.; Höing, R. S.; Junkes, A.; Klanner, R.; Kogler, R.; Kovalchuk, N.; Lapsien, T.; Lenz, T.; Marchesini, I.; Marconi, D.; Meyer, M.; Niedziela, M.; Nowatschin, D.; Ott, J.; Pantaleo, F.; Peiffer, T.; Perieanu, A.; Pietsch, N.; Poehlsen, J.; Sander, C.; Scharf, C.; Schleper, P.; Schlieckau, E.; Schmidt, A.; Schumann, S.; Schwandt, J.; Stadie, H.; Steinbrück, G.; Stober, F. M.; Stöver, M.; Tholen, H.; Troendle, D.; Usai, E.; Vanelderen, L.; Vanhoefer, A.; Vormwald, B.; Barth, C.; Baus, C.; Berger, J.; Butz, E.; Chwalek, T.; Colombo, F.; De Boer, W.; Dierlamm, A.; Fink, S.; Friese, R.; Giffels, M.; Gilbert, A.; Haitz, D.; Hartmann, F.; Heindl, S. M.; Husemann, U.; Katkov, I.; Kornmayer, A.; Lobelle Pardo, P.; Maier, B.; Mildner, H.; Mozer, M. U.; Müller, T.; Müller, Th.; Plagge, M.; Quast, G.; Rabbertz, K.; Röcker, S.; Roscher, F.; Schröder, M.; Sieber, G.; Simonis, H. J.; Ulrich, R.; Wagner-Kuhr, J.; Wayand, S.; Weber, M.; Weiler, T.; Williamson, S.; Wöhrmann, C.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Giakoumopoulou, V. A.; Kyriakis, A.; Loukas, D.; Topsis-Giotis, I.; Agapitos, A.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Tziaferi, E.; Evangelou, I.; Flouris, G.; Foudas, C.; Kokkas, P.; Loukas, N.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Filipovic, N.; Bencze, G.; Hajdu, C.; Hidas, P.; Horvath, D.; Sikler, F.; Veszpremi, V.; Vesztergombi, G.; Zsigmond, A. J.; Beni, N.; Czellar, S.; Karancsi, J.; Molnar, J.; Szillasi, Z.; Bartók, M.; Makovec, A.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Bahinipati, S.; Choudhury, S.; Mal, P.; Mandal, K.; Nayak, A.; Sahoo, D. K.; Sahoo, N.; Swain, S. K.; Bansal, S.; Beri, S. B.; Bhatnagar, V.; Chawla, R.; Gupta, R.; Bhawandeep, U.; Kalsi, A. K.; Kaur, A.; Kaur, M.; Kumar, R.; Mehta, A.; Mittal, M.; Singh, J. B.; Walia, G.; Kumar, Ashok; Bhardwaj, A.; Choudhary, B. C.; Garg, R. B.; Keshri, S.; Kumar, A.; Malhotra, S.; Naimuddin, M.; Nishu, N.; Ranjan, K.; Sharma, R.; Sharma, V.; Bhattacharya, R.; Bhattacharya, S.; Chatterjee, K.; Dey, S.; Dutt, S.; Dutta, S.; Ghosh, S.; Majumdar, N.; Modak, A.; Mondal, K.; Mukhopadhyay, S.; Nandan, S.; Purohit, A.; Roy, A.; Roy, D.; Roy Chowdhury, S.; Sarkar, S.; Sharan, M.; Thakur, S.; Behera, P. K.; Chudasama, R.; Dutta, D.; Jha, V.; Kumar, V.; Mohanty, A. K.; Netrakanti, P. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Dugad, S.; Kole, G.; Mahakud, B.; Mitra, S.; Mohanty, G. B.; Sur, N.; Sutar, B.; Banerjee, S.; Bhowmik, S.; Dewanjee, R. K.; Ganguly, S.; Guchait, M.; Jain, Sa.; Kumar, S.; Maity, M.; Majumder, G.; Mazumdar, K.; Parida, B.; Sarkar, T.; Wickramage, N.; Chauhan, S.; Dube, S.; Kapoor, A.; Kothekar, K.; Rane, A.; Sharma, S.; Bakhshiansohi, H.; Behnamian, H.; Chenarani, S.; Eskandari Tadavani, E.; Etesami, S. M.; Fahim, A.; Khakzad, M.; Mohammadi Najafabadi, M.; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Caputo, C.; Colaleo, A.; Creanza, D.; Cristella, L.; De Filippis, N.; De Palma, M.; Fiore, L.; Iaselli, G.; Maggi, G.; Maggi, M.; Miniello, G.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Ranieri, A.; Selvaggi, G.; Silvestris, L.; Venditti, R.; Abbiendi, G.; Battilana, C.; Bonacorsi, D.; Braibant-Giacomelli, S.; Brigliadori, L.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Chhibra, S. S.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Grandi, C.; Guiducci, L.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Albergo, S.; Chiorboli, M.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Gori, V.; Lenzi, P.; Meschini, M.; Paoletti, S.; Sguazzoni, G.; Viliani, L.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Primavera, F.; Calvelli, V.; Ferro, F.; Lo Vetere, M.; Monge, M. R.; Robutti, E.; Tosi, S.; Brianza, L.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Ghezzi, A.; Govoni, P.; Malvezzi, S.; Manzoni, R. A.; Marzocchi, B.; Menasce, D.; Moroni, L.; Paganoni, M.; Pedrini, D.; Pigazzini, S.; Ragazzi, S.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; De Nardo, G.; Di Guida, S.; Esposito, M.; Fabozzi, F.; Iorio, A. O. M.; Lanza, G.; Lista, L.; Meola, S.; Merola, M.; Paolucci, P.; Sciacca, C.; Thyssen, F.; Azzi, P.; Bacchetta, N.; Benato, L.; Bisello, D.; Boletti, A.; Carlin, R.; Carvalho Antunes De Oliveira, A.; Checchia, P.; Dall'Osso, M.; De Castro Manzano, P.; Dorigo, T.; Dosselli, U.; Gasparini, F.; Gasparini, U.; Gozzelino, A.; Lacaprara, S.; Margoni, M.; Meneguzzo, A. T.; Pazzini, J.; Pozzobon, N.; Ronchese, P.; Simonetto, F.; Torassa, E.; Tosi, M.; Zanetti, M.; Zotto, P.; Zucchetta, A.; Zumerle, G.; Braghieri, A.; Magnani, A.; Montagna, P.; Ratti, S. P.; Re, V.; Riccardi, C.; Salvini, P.; Vai, I.; Vitulo, P.; Alunni Solestizi, L.; Bilei, G. M.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Leonardi, R.; Mantovani, G.; Menichelli, M.; Saha, A.; Santocchia, A.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Bernardini, J.; Boccali, T.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Donato, S.; Fedi, G.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Martini, L.; Messineo, A.; Palla, F.; Rizzi, A.; Savoy-Navarro, A.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Barone, L.; Cavallari, F.; Cipriani, M.; D'imperio, G.; Del Re, D.; Diemoz, M.; Gelli, S.; Jorda, C.; Longo, E.; Margaroli, F.; Meridiani, P.; Organtini, G.; Paramatti, R.; Preiato, F.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bartosik, N.; Bellan, R.; Biino, C.; Cartiglia, N.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Finco, L.; Kiani, B.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Monteil, E.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Ravera, F.; Romero, A.; Ruspa, M.; Sacchi, R.; Shchelina, K.; Sola, V.; Solano, A.; Staiano, A.; Traczyk, P.; Belforte, S.; Candelise, V.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; La Licata, C.; Schizzi, A.; Zanetti, A.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Lee, S.; Lee, S. W.; Oh, Y. D.; Sekmen, S.; Son, D. C.; Yang, Y. C.; Kim, H.; Lee, A.; Brochero Cifuentes, J. A.; Kim, T. J.; Cho, S.; Choi, S.; Go, Y.; Gyun, D.; Ha, S.; Hong, B.; Jo, Y.; Kim, Y.; Lee, B.; Lee, K.; Lee, K. S.; Lee, S.; Lim, J.; Park, S. K.; Roh, Y.; Almond, J.; Kim, J.; Oh, S. B.; Seo, S. h.; Yang, U. K.; Yoo, H. D.; Yu, G. B.; Choi, M.; Kim, H.; Kim, H.; Kim, J. H.; Lee, J. S. H.; Park, I. C.; Ryu, G.; Ryu, M. S.; Choi, Y.; Goh, J.; Kim, D.; Kwon, E.; Lee, J.; Yu, I.; Dudenas, V.; Juodagalvis, A.; Vaitkus, J.; Ahmed, I.; Ibrahim, Z. A.; Komaragiri, J. R.; Md Ali, M. A. B.; Mohamad Idris, F.; Wan Abdullah, W. A. T.; Yusli, M. N.; Zolkapli, Z.; Casimiro Linares, E.; Castilla-Valdez, H.; De La Cruz-Burelo, E.; Heredia-De La Cruz, I.; Hernandez-Almada, A.; Lopez-Fernandez, R.; Mejia Guisao, J.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Vazquez Valencia, F.; Pedraza, I.; Salazar Ibarguen, H. A.; Uribe Estrada, C.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Khan, W. A.; Qazi, S.; Shoaib, M.; Waqas, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Romanowska-Rybinska, K.; Szleper, M.; Zalewski, P.; Bunkowski, K.; Byszuk, A.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Misiura, M.; Olszewski, M.; Walczak, M.; Bargassa, P.; Beirão Da Cruz E Silva, C.; Di Francesco, A.; Faccioli, P.; Ferreira Parracho, P. G.; Gallinaro, M.; Hollar, J.; Leonardo, N.; Lloret Iglesias, L.; Nemallapudi, M. V.; Rodrigues Antunes, J.; Seixas, J.; Toldaiev, O.; Vadruccio, D.; Varela, J.; Vischia, P.; Bunin, P.; Gavrilenko, M.; Golutvin, I.; Gorbounov, N.; Gorbunov, I.; Karjavin, V.; Kozlov, G.; Lanev, A.; Malakhov, A.; Matveev, V.; Moisenz, P.; Palichik, V.; Perelygin, V.; Savina, M.; Shmatov, S.; Shulha, S.; Skatchkov, N.; Smirnov, V.; Zarubin, A.; Chtchipounov, L.; Golovtsov, V.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Murzin, V.; Oreshkin, V.; Sulimov, V.; Vorobyev, A.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Karneyeu, A.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Spiridonov, A.; Toms, M.; Vlasov, E.; Zhokin, A.; Chadeeva, M.; Danilov, M.; Zhemchugov, E.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Leonidov, A.; Rusakov, S. V.; Terkulov, A.; Baskakov, A.; Belyaev, A.; Boos, E.; Dubinin, M.; Dudko, L.; Ershov, A.; Gribushin, A.; Klyukhin, V.; Kodolova, O.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Snigirev, A.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Elumakhov, D.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Krychkine, V.; Petrov, V.; Ryutin, R.; Sobol, A.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Adzic, P.; Cirkovic, P.; Devetak, D.; Milosevic, J.; Rekovic, V.; Alcaraz Maestre, J.; Calvo, E.; Cerrada, M.; Chamizo Llatas, M.; Colino, N.; De La Cruz, B.; Delgado Peris, A.; Escalante Del Valle, A.; Fernandez Bedoya, C.; Fernández Ramos, J. P.; Flix, J.; Fouz, M. C.; Garcia-Abia, P.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Navarro De Martino, E.; Pérez-Calero Yzquierdo, A.; Puerta Pelayo, J.; Quintario Olmeda, A.; Redondo, I.; Romero, L.; Soares, M. S.; de Trocóniz, J. F.; Missiroli, M.; Moran, D.; Cuevas, J.; Fernandez Menendez, J.; Gonzalez Caballero, I.; Palencia Cortezon, E.; Sanchez Cruz, S.; Vizan Garcia, J. M.; Cabrillo, I. J.; Calderon, A.; Castiñeiras De Saa, J. R.; Curras, E.; Fernandez, M.; Garcia-Ferrero, J.; Gomez, G.; Lopez Virto, A.; Marco, J.; Martinez Rivero, C.; Matorras, F.; Piedra Gomez, J.; Rodrigo, T.; Ruiz-Jimeno, A.; Scodellaro, L.; Trevisani, N.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Auffray, E.; Auzinger, G.; Bachtis, M.; Baillon, P.; Ball, A. H.; Barney, D.; Bloch, P.; Bocci, A.; Bonato, A.; Botta, C.; Camporesi, T.; Castello, R.; Cepeda, M.; Cerminara, G.; D'Alfonso, M.; d'Enterria, D.; Dabrowski, A.; Daponte, V.; David, A.; De Gruttola, M.; De Guio, F.; De Roeck, A.; Di Marco, E.; Dobson, M.; Dordevic, M.; Dorney, B.; du Pree, T.; Duggan, D.; Dünser, M.; Dupont, N.; Elliott-Peisert, A.; Fartoukh, S.; Franzoni, G.; Fulcher, J.; Funk, W.; Gigi, D.; Gill, K.; Girone, M.; Glege, F.; Gundacker, S.; Guthoff, M.; Hammer, J.; Harris, P.; Hegeman, J.; Innocente, V.; Janot, P.; Kirschenmann, H.; Knünz, V.; Kortelainen, M. J.; Kousouris, K.; Krammer, M.; Lecoq, P.; Lourenço, C.; Lucchini, M. T.; Magini, N.; Malgeri, L.; Mannelli, M.; Martelli, A.; Meijers, F.; Mersi, S.; Meschi, E.; Moortgat, F.; Morovic, S.; Mulders, M.; Neugebauer, H.; Orfanelli, S.; Orsini, L.; Pape, L.; Perez, E.; Peruzzi, M.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Pierini, M.; Racz, A.; Reis, T.; Rolandi, G.; Rovere, M.; Ruan, M.; Sakulin, H.; Sauvan, J. B.; Schäfer, C.; Schwick, C.; Seidel, M.; Sharma, A.; Silva, P.; Simon, M.; Sphicas, P.; Steggemann, J.; Stoye, M.; Takahashi, Y.; Treille, D.; Triossi, A.; Tsirou, A.; Veckalns, V.; Veres, G. I.; Wardle, N.; Zagozdzinska, A.; Zeuner, W. D.; Bertl, W.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Rohe, T.; Bachmair, F.; Bäni, L.; Bianchini, L.; Casal, B.; Dissertori, G.; Dittmar, M.; Donegà, M.; Eller, P.; Grab, C.; Heidegger, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Lecomte, P.; Lustermann, W.; Mangano, B.; Marionneau, M.; Martinez Ruiz del Arbol, P.; Masciovecchio, M.; Meinhard, M. T.; Meister, D.; Micheli, F.; Musella, P.; Nessi-Tedaldi, F.; Pandolfi, F.; Pata, J.; Pauss, F.; Perrin, G.; Perrozzi, L.; Quittnat, M.; Rossini, M.; Schönenberger, M.; Starodumov, A.; Takahashi, M.; Tavolaro, V. R.; Theofilatos, K.; Wallny, R.; Aarrestad, T. K.; Amsler, C.; Caminada, L.; Canelli, M. F.; Chiochia, V.; De Cosa, A.; Galloni, C.; Hinzmann, A.; Hreus, T.; Kilminster, B.; Lange, C.; Ngadiuba, J.; Pinna, D.; Rauco, G.; Robmann, P.; Salerno, D.; Yang, Y.; Doan, T. H.; Jain, Sh.; Khurana, R.; Konyushikhin, M.; Kuo, C. M.; Lin, W.; Lu, Y. J.; Pozdnyakov, A.; Yu, S. S.; Kumar, Arun; Chang, P.; Chang, Y. H.; Chang, Y. W.; Chao, Y.; Chen, K. F.; Chen, P. H.; Dietz, C.; Fiori, F.; Hou, W.-S.; Hsiung, Y.; Liu, Y. F.; Lu, R.-S.; Miñano Moya, M.; Paganis, E.; Psallidas, A.; Tsai, J. f.; Tzeng, Y. M.; Asavapibhop, B.; Singh, G.; Srimanobhas, N.; Suwonjandee, N.; Adiguzel, A.; Cerci, S.; Damarseckin, S.; Demiroglu, Z. S.; Dozen, C.; Dumanoglu, I.; Girgis, S.; Gokbulut, G.; Guler, Y.; Gurpinar, E.; Hos, I.; Kangal, E. E.; Onengut, G.; Ozdemir, K.; Sunar Cerci, D.; Tali, B.; Topakli, H.; Zorbilmez, C.; Bilin, B.; Bilmis, S.; Isildak, B.; Karapinar, G.; Yalvac, M.; Zeyrek, M.; Gülmez, E.; Kaya, M.; Kaya, O.; Yetkin, E. A.; Yetkin, T.; Cakir, A.; Cankocak, K.; Sen, S.; Vardarlı, F. I.; Grynyov, B.; Levchuk, L.; Sorokin, P.; Aggleton, R.; Ball, F.; Beck, L.; Brooke, J. J.; Burns, D.; Clement, E.; Cussans, D.; Flacher, H.; Goldstein, J.; Grimes, M.; Heath, G. P.; Heath, H. F.; Jacob, J.; Kreczko, L.; Lucas, C.; Meng, Z.; Newbold, D. M.; Paramesvaran, S.; Poll, A.; Sakuma, T.; Seif El Nasr-storey, S.; Senkin, S.; Smith, D.; Smith, V. J.; Bell, K. W.; Belyaev, A.; Brew, C.; Brown, R. M.; Calligaris, L.; Cieri, D.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Baber, M.; Bainbridge, R.; Buchmuller, O.; Bundock, A.; Burton, D.; Casasso, S.; Citron, M.; Colling, D.; Corpe, L.; Dauncey, P.; Davies, G.; De Wit, A.; Della Negra, M.; Dunne, P.; Elwood, A.; Futyan, D.; Haddad, Y.; Hall, G.; Iles, G.; Lane, R.; Laner, C.; Lucas, R.; Lyons, L.; Magnan, A.-M.; Malik, S.; Mastrolorenzo, L.; Nash, J.; Nikitenko, A.; Pela, J.; Penning, B.; Pesaresi, M.; Raymond, D. M.; Richards, A.; Rose, A.; Seez, C.; Tapper, A.; Uchida, K.; Vazquez Acosta, M.; Virdee, T.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Leslie, D.; Reid, I. D.; Symonds, P.; Teodorescu, L.; Turner, M.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Charaf, O.; Cooper, S. I.; Henderson, C.; Rumerio, P.; Arcaro, D.; Avetisyan, A.; Bose, T.; Gastler, D.; Rankin, D.; Richardson, C.; Rohlf, J.; Sulak, L.; Zou, D.; Benelli, G.; Berry, E.; Cutts, D.; Ferapontov, A.; Garabedian, A.; Hakala, J.; Heintz, U.; Jesus, O.; Laird, E.; Landsberg, G.; Mao, Z.; Narain, M.; Piperov, S.; Sagir, S.; Spencer, E.; Syarif, R.; Breedon, R.; Breto, G.; Burns, D.; Calderon De La Barca Sanchez, M.; Chauhan, S.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Flores, C.; Funk, G.; Gardner, M.; Ko, W.; Lander, R.; Mclean, C.; Mulhearn, M.; Pellett, D.; Pilot, J.; Ricci-Tam, F.; Shalhout, S.; Smith, J.; Squires, M.; Stolp, D.; Tripathi, M.; Wilbur, S.; Yohay, R.; Cousins, R.; Everaerts, P.; Florent, A.; Hauser, J.; Ignatenko, M.; Saltzberg, D.; Takasugi, E.; Valuev, V.; Weber, M.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Hanson, G.; Heilman, J.; Jandir, P.; Kennedy, E.; Lacroix, F.; Long, O. R.; Malberti, M.; Olmedo Negrete, M.; Paneva, M. I.; Shrinivas, A.; Wei, H.; Wimpenny, S.; Yates, B. R.; Branson, J. G.; Cerati, G. B.; Cittolin, S.; D'Agnolo, R. T.; Derdzinski, M.; Gerosa, R.; Holzner, A.; Kelley, R.; Klein, D.; Letts, J.; Macneill, I.; Olivito, D.; Padhi, S.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Vartak, A.; Wasserbaech, S.; Welke, C.; Wood, J.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Bhandari, R.; Bradmiller-Feld, J.; Campagnari, C.; Dishaw, A.; Dutta, V.; Flowers, K.; Franco Sevilla, M.; Geffert, P.; George, C.; Golf, F.; Gouskos, L.; Gran, J.; Heller, R.; Incandela, J.; Mccoll, N.; Mullin, S. D.; Ovcharova, A.; Richman, J.; Stuart, D.; Suarez, I.; West, C.; Yoo, J.; Anderson, D.; Apresyan, A.; Bendavid, J.; Bornheim, A.; Bunn, J.; Chen, Y.; Duarte, J.; Mott, A.; Newman, H. B.; Pena, C.; Spiropulu, M.; Vlimant, J. R.; Xie, S.; Zhu, R. Y.; Andrews, M. B.; Azzolini, V.; Calamba, A.; Carlson, B.; Ferguson, T.; Paulini, M.; Russ, J.; Sun, M.; Vogel, H.; Vorobiev, I.; Cumalat, J. P.; Ford, W. T.; Jensen, F.; Johnson, A.; Krohn, M.; Mulholland, T.; Stenson, K.; Wagner, S. R.; Alexander, J.; Chaves, J.; Chu, J.; Dittmer, S.; Mirman, N.; Nicolas Kaufman, G.; Patterson, J. R.; Rinkevicius, A.; Ryd, A.; Skinnari, L.; Sun, W.; Tan, S. M.; Tao, Z.; Thom, J.; Tucker, J.; Wittich, P.; Winn, D.; Abdullin, S.; Albrow, M.; Apollinari, G.; Banerjee, S.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Cheung, H. W. K.; Chlebana, F.; Cihangir, S.; Cremonesi, M.; Elvira, V. D.; Fisk, I.; Freeman, J.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Hare, D.; Harris, R. M.; Hasegawa, S.; Hirschauer, J.; Hu, Z.; Jayatilaka, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Klima, B.; Kreis, B.; Lammel, S.; Linacre, J.; Lincoln, D.; Lipton, R.; Liu, T.; Lopes De Sá, R.; Lykken, J.; Maeshima, K.; Marraffino, J. M.; Maruyama, S.; Mason, D.; McBride, P.; Merkel, P.; Mrenna, S.; Nahn, S.; Newman-Holmes, C.; O'Dell, V.; Pedro, K.; Prokofyev, O.; Rakness, G.; Ristori, L.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Stoynev, S.; Strobbe, N.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vernieri, C.; Verzocchi, M.; Vidal, R.; Wang, M.; Weber, H. A.; Whitbeck, A.; Acosta, D.; Avery, P.; Bortignon, P.; Bourilkov, D.; Brinkerhoff, A.; Carnes, A.; Carver, M.; Curry, D.; Das, S.; Field, R. D.; Furic, I. K.; Konigsberg, J.; Korytov, A.; Ma, P.; Matchev, K.; Mei, H.; Milenovic, P.; Mitselmakher, G.; Rank, D.; Shchutska, L.; Sperka, D.; Thomas, L.; Wang, J.; Wang, S.; Yelton, J.; Linn, S.; Markowitz, P.; Martinez, G.; Rodriguez, J. L.; Ackert, A.; Adams, J. R.; Adams, T.; Askew, A.; Bein, S.; Diamond, B.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Khatiwada, A.; Prosper, H.; Santra, A.; Weinberg, M.; Baarmand, M. M.; Bhopatkar, V.; Colafranceschi, S.; Hohlmann, M.; Kalakhety, H.; Noonan, D.; Roy, T.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Bucinskaite, I.; Cavanaugh, R.; Evdokimov, O.; Gauthier, L.; Gerber, C. E.; Hofman, D. J.; Kurt, P.; O'Brien, C.; Sandoval Gonzalez, I. D.; Turner, P.; Varelas, N.; Wu, Z.; Zakaria, M.; Zhang, J.; Bilki, B.; Clarida, W.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Snyder, C.; Tiras, E.; Wetzel, J.; Yi, K.; Anderson, I.; Blumenfeld, B.; Cocoros, A.; Eminizer, N.; Fehling, D.; Feng, L.; Gritsan, A. V.; Maksimovic, P.; Osherson, M.; Roskes, J.; Sarica, U.; Swartz, M.; Xiao, M.; Xin, Y.; You, C.; Al-bataineh, A.; Baringer, P.; Bean, A.; Bowen, J.; Bruner, C.; Castle, J.; Kenny, R. P.; Kropivnitskaya, A.; Majumder, D.; Mcbrayer, W.; Murray, M.; Sanders, S.; Stringer, R.; Tapia Takaki, J. D.; Wang, Q.; Ivanov, A.; Kaadze, K.; Khalil, S.; Makouski, M.; Maravin, Y.; Mohammadi, A.; Saini, L. K.; Skhirtladze, N.; Toda, S.; Lange, D.; Rebassoo, F.; Wright, D.; Anelli, C.; Baden, A.; Baron, O.; Belloni, A.; Calvert, B.; Eno, S. C.; Ferraioli, C.; Gomez, J. A.; Hadley, N. J.; Jabeen, S.; Kellogg, R. G.; Kolberg, T.; Kunkle, J.; Lu, Y.; Mignerey, A. C.; Shin, Y. H.; Skuja, A.; Tonjes, M. B.; Tonwar, S. C.; Apyan, A.; Barbieri, R.; Baty, A.; Bi, R.; Bierwagen, K.; Brandt, S.; Busza, W.; Cali, I. A.; Demiragli, Z.; Di Matteo, L.; Gomez Ceballos, G.; Goncharov, M.; Gulhan, D.; Hsu, D.; Iiyama, Y.; Innocenti, G. M.; Klute, M.; Kovalskyi, D.; Krajczar, K.; Lai, Y. S.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Marini, A. C.; Mcginn, C.; Mironov, C.; Narayanan, S.; Niu, X.; Paus, C.; Roland, C.; Roland, G.; Salfeld-Nebgen, J.; Stephans, G. S. F.; Sumorok, K.; Tatar, K.; Varma, M.; Velicanu, D.; Veverka, J.; Wang, J.; Wang, T. W.; Wyslouch, B.; Yang, M.; Zhukova, V.; Benvenuti, A. C.; Chatterjee, R. M.; Dahmes, B.; Evans, A.; Finkel, A.; Gude, A.; Hansen, P.; Kalafut, S.; Kao, S. C.; Klapoetke, K.; Kubota, Y.; Lesko, Z.; Mans, J.; Nourbakhsh, S.; Ruckstuhl, N.; Rusack, R.; Tambe, N.; Turkewitz, J.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bartek, R.; Bloom, K.; Bose, S.; Claes, D. R.; Dominguez, A.; Fangmeier, C.; Gonzalez Suarez, R.; Kamalieddin, R.; Knowlton, D.; Kravchenko, I.; Meier, F.; Monroy, J.; Siado, J. E.; Snow, G. R.; Stieger, B.; Alyari, M.; Dolen, J.; George, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Kaisen, J.; Kharchilava, A.; Kumar, A.; Parker, A.; Rappoccio, S.; Roozbahani, B.; Alverson, G.; Barberis, E.; Baumgartel, D.; Chasco, M.; Hortiangtham, A.; Massironi, A.; Morse, D. M.; Nash, D.; Orimoto, T.; Teixeira De Lima, R.; Trocino, D.; Wang, R.-J.; Wood, D.; Bhattacharya, S.; Hahn, K. A.; Kubik, A.; Low, J. F.; Mucia, N.; Odell, N.; Pollack, B.; Schmitt, M. H.; Sung, K.; Trovato, M.; Velasco, M.; Dev, N.; Hildreth, M.; Hurtado Anampa, K.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Marinelli, N.; Meng, F.; Mueller, C.; Musienko, Y.; Planer, M.; Reinsvold, A.; Ruchti, R.; Rupprecht, N.; Smith, G.; Taroni, S.; Valls, N.; Wayne, M.; Wolf, M.; Woodard, A.; Alimena, J.; Antonelli, L.; Brinson, J.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Francis, B.; Hart, A.; Hill, C.; Hughes, R.; Ji, W.; Liu, B.; Luo, W.; Puigh, D.; Rodenburg, M.; Winer, B. L.; Wulsin, H. W.; Cooperstein, S.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Luo, J.; Marlow, D.; Medvedeva, T.; Mooney, M.; Olsen, J.; Palmer, C.; Piroué, P.; Stickland, D.; Tully, C.; Zuranski, A.; Malik, S.; Barker, A.; Barnes, V. E.; Benedetti, D.; Folgueras, S.; Gutay, L.; Jha, M. K.; Jones, M.; Jung, A. W.; Jung, K.; Miller, D. H.; Neumeister, N.; Radburn-Smith, B. C.; Shi, X.; Sun, J.; Svyatkovskiy, A.; Wang, F.; Xie, W.; Xu, L.; Parashar, N.; Stupak, J.; Adair, A.; Akgun, B.; Chen, Z.; Ecklund, K. M.; Geurts, F. J. M.; Guilbaud, M.; Li, W.; Michlin, B.; Northup, M.; Padley, B. P.; Redjimi, R.; Roberts, J.; Rorie, J.; Tu, Z.; Zabel, J.; Betchart, B.; Bodek, A.; de Barbaro, P.; Demina, R.; Duh, Y. t.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Han, J.; Hindrichs, O.; Khukhunaishvili, A.; Lo, K. H.; Tan, P.; Verzetti, M.; Chou, J. P.; Contreras-Campana, E.; Gershtein, Y.; Gómez Espinosa, T. A.; Halkiadakis, E.; Heindl, M.; Hidas, D.; Hughes, E.; Kaplan, S.; Kunnawalkam Elayavalli, R.; Kyriacou, S.; Lath, A.; Nash, K.; Saka, H.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Foerster, M.; Heideman, J.; Riley, G.; Rose, K.; Spanier, S.; Thapa, K.; Bouhali, O.; Castaneda Hernandez, A.; Celik, A.; Dalchenko, M.; De Mattia, M.; Delgado, A.; Dildick, S.; Eusebi, R.; Gilmore, J.; Huang, T.; Juska, E.; Kamon, T.; Krutelyov, V.; Mueller, R.; Pakhotin, Y.; Patel, R.; Perloff, A.; Perniè, L.; Rathjens, D.; Rose, A.; Safonov, A.; Tatarinov, A.; Ulmer, K. A.; Akchurin, N.; Cowden, C.; Damgov, J.; Dragoiu, C.; Dudero, P. R.; Faulkner, J.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Libeiro, T.; Undleeb, S.; Volobouev, I.; Wang, Z.; Delannoy, A. G.; Greene, S.; Gurrola, A.; Janjam, R.; Johns, W.; Maguire, C.; Melo, A.; Ni, H.; Sheldon, P.; Tuo, S.; Velkovska, J.; Xu, Q.; Arenton, M. W.; Barria, P.; Cox, B.; Goodell, J.; Hirosky, R.; Ledovskoy, A.; Li, H.; Neu, C.; Sinthuprasith, T.; Sun, X.; Wang, Y.; Wolfe, E.; Xia, F.; Clarke, C.; Harr, R.; Karchin, P. E.; Lamichhane, P.; Sturdy, J.; Belknap, D. A.; Dasu, S.; Dodd, L.; Duric, S.; Gomber, B.; Grothe, M.; Herndon, M.; Hervé, A.; Klabbers, P.; Lanaro, A.; Levine, A.; Long, K.; Loveless, R.; Ojalvo, I.; Perry, T.; Pierro, G. A.; Polese, G.; Ruggles, T.; Savin, A.; Sharma, A.; Smith, N.; Smith, W. H.; Taylor, D.; Verwilligen, P.; Woods, N.; CMS Collaboration
2016-07-01
A search for narrow resonances decaying into dijet final states is performed on data from proton-proton collisions at a center-of-mass energy of 8 TeV, corresponding to an integrated luminosity of 18.8 fb-1 . The data were collected with the CMS detector using a novel technique called data scouting, in which the information associated with these selected events is much reduced, permitting collection of larger data samples. This technique enables CMS to record events containing jets at a rate of 1 kHz, by collecting the data from the high-level-trigger system. In this way, the sensitivity to low-mass resonances is increased significantly, allowing previously inaccessible couplings of new resonances to quarks and gluons to be probed. The resulting dijet mass distribution yields no evidence of narrow resonances. Upper limits are presented on the resonance cross sections as a function of mass, and compared with a variety of models predicting narrow resonances. The limits are translated into upper limits on the coupling of a leptophobic resonance ZB' to quarks, improving on the results obtained by previous experiments for the mass range from 500 to 800 GeV.
NASA Astrophysics Data System (ADS)
Goldenstein, Christopher S.; Jeffries, Jay B.; Hanson, Ronald K.
2013-11-01
Absorption lineshapes for two unresolved H2O doublets near 4029.52 and 4041.92 cm-1 were measured at high-resolution in a heated static cell using two distributed-feedback diode lasers. Measurements were acquired for H2O, CO2, and N2 perturbers over a temperature and pressure range of 650-1325 K and 2-760 Torr, respectively. Strong collisional narrowing effects were observed in CO2 and N2, but not in pure H2O. The Galatry profile was used to infer collisional-broadening and -narrowing coefficients and their respective temperature dependence for CO2 and N2 perturbers. The collisional-broadening and -narrowing coefficients for CO2 perturbers were found to decrease with increasing temperature in a similar manner. For N2 perturbers, the collisional-broadening coefficients increased with temperature while the collisional-narrowing coefficients decreased with increasing temperature. Self-broadening coefficients were inferred from Voigt profile fits and are compared with HITEMP 2010. The linestrengths of 17 H2O transitions are also reported.
Kampouraki, Emmanouela; Avery, Peter J; Wynne, Hilary; Biss, Tina; Hanley, John; Talks, Kate; Kamali, Farhad
2017-09-01
Current guidelines advocate using fixed-doses of oral vitamin K to reverse excessive anticoagulation in warfarinised patients who are either asymptomatic or have minor bleeds. Over-anticoagulated patients present with a wide range of International Normalised Ratio (INR) values and response to fixed doses of vitamin K varies. Consequently a significant proportion of patients remain outside their target INR after vitamin K administration, making them prone to either haemorrhage or thromboembolism. We compared the performance of a novel tailored vitamin K dosing regimen to that of a fixed-dose regimen with the primary measure being the proportion of over-anticoagulated patients returning to their target INR within 24 h. One hundred and eighty-one patients with an index INR > 6·0 (asymptomatic or with minor bleeding) were randomly allocated to receive oral administration of either a tailored dose (based upon index INR and body surface area) or a fixed-dose (1 or 2 mg) of vitamin K. A greater proportion of patients treated with the tailored dose returned to within target INR range compared to the fixed-dose regimen (68·9% vs. 52·8%; P = 0·026), whilst a smaller proportion of patients remained above target INR range (12·2% vs. 34·0%; P < 0·001). Individualised vitamin K dosing is more accurate than fixed-dose regimen in lowering INR to within target range in excessively anticoagulated patients. © 2017 John Wiley & Sons Ltd.
Preparation of metallic nanoparticles by irradiation in starch aqueous solution
NASA Astrophysics Data System (ADS)
NemÅ£anu, Monica R.; Braşoveanu, Mirela; Iacob, Nicuşor
2014-11-01
Colloidal silver nanoparticles (AgNPs) were synthesized in a single step by electron beam irradiation reduction of silver ions in aqueous solution containing starch. The nanoparticles were characterized by spectrophotocolorimetry and compared with those obtained by chemical (thermal) reduction method. The results showed that the smaller sizes of AgNPs were prepared with higher yields as the irradiation dose increased. The broadening of particle size distribution occurred by increasing of irradiation dose and dose rate. Chromatic parameters such as b* (yellow-blue coordinate), C* (chroma) and ΔEab (total color difference) could characterize the nanoparticles with respect of their concentration. Hue angle ho was correlated to the particle size distribution. Experimental data of the irradiated samples were also subjected to factor analysis using principal component extraction and varimax rotation in order to reveal the relation between dependent variables and independent variables and to reduce their number. The radiation-based method provided silver nanoparticles with higher concentration and narrower size distribution than those produced by chemical reduction method. Therefore, the electron beam irradiation is effective for preparation of silver nanoparticles using starch aqueous solution as dispersion medium.
Feasibility of online IMPT adaptation using fast, automatic and robust dose restoration
NASA Astrophysics Data System (ADS)
Bernatowicz, Kinga; Geets, Xavier; Barragan, Ana; Janssens, Guillaume; Souris, Kevin; Sterpin, Edmond
2018-04-01
Intensity-modulated proton therapy (IMPT) offers excellent dose conformity and healthy tissue sparing, but it can be substantially compromised in the presence of anatomical changes. A major dosimetric effect is caused by density changes, which alter the planned proton range in the patient. Three different methods, which automatically restore an IMPT plan dose on a daily CT image were implemented and compared: (1) simple dose restoration (DR) using optimization objectives of the initial plan, (2) voxel-wise dose restoration (vDR), and (3) isodose volume dose restoration (iDR). Dose restorations were calculated for three different clinical cases, selected to test different capabilities of the restoration methods: large range adaptation, complex dose distributions and robust re-optimization. All dose restorations were obtained in less than 5 min, without manual adjustments of the optimization settings. The evaluation of initial plans on repeated CTs showed large dose distortions, which were substantially reduced after restoration. In general, all dose restoration methods improved DVH-based scores in propagated target volumes and OARs. Analysis of local dose differences showed that, although all dose restorations performed similarly in high dose regions, iDR restored the initial dose with higher precision and accuracy in the whole patient anatomy. Median dose errors decreased from 13.55 Gy in distorted plan to 9.75 Gy (vDR), 6.2 Gy (DR) and 4.3 Gy (iDR). High quality dose restoration is essential to minimize or eventually by-pass the physician approval of the restored plan, as long as dose stability can be assumed. Motion (as well as setup and range uncertainties) can be taken into account by including robust optimization in the dose restoration. Restoring clinically-approved dose distribution on repeated CTs does not require new ROI segmentation and is compatible with an online adaptive workflow.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, J; Strauss, D; Langner, U
Purpose: To establish patient surface dose dosimetry for scanning proton beam therapy (SPBT) for breast cancer using optically stimulated luminescence dosimeters (OSLD). Methods: OSLDs were calibrated with SPB under the similar conditions as the treatments for breast cancer. A range shifter (RS) of 5 cm water equivalent thickness (WET) was used. The air gap from the surface of the range shifter to the surface of the phantom was 15 cm. A uniform planar dose generated by nominal energy of 118 MeV was delivered. The range of 118 MeV proton beam after the 5cm RS is approximately 5 cm in water,more » which is the common range for breast treatments. The OSLDs were placed on the surface of high density polyethylene slabs, and a bolus of 1.06 cm WET was used for buildup. A variety of dose levels in the range of 0.5 to 8 Gy were delivered. Under the same condition, an ADCL calibrated parallel plate (PP) chamber was used to measure the reference dose. The correlation between the output signals of OSLDs and the reference doses was established. The calibration of OSLD was verified against the PP chamber measurements for two SPBT breast plans calculated for two patients. Results: the least squares fitting for the OSLD calibration curve was a polynomial function to the order of 2 in the range of 0.5 to 8 Gy (RBE). The differences between the dose measured with OSLDs and PP chamber were within 3% for the two breast proton plans. Conclusion: the calibrated OSLDs under the similar conditions as the treatments can be used for patient surface dose measurements.« less
Zhao, Li; Chen, Chunxia; Li, Bei; Dong, Li; Guo, Yingqiang; Xiao, Xijun; Zhang, Eryong; Qin, Li
2014-01-01
Objective To study the performance of pharmacogenetics-based warfarin dosing algorithms in the initial and the stable warfarin treatment phases in a cohort of Han-Chinese patients undertaking mechanic heart valve replacement. Methods We searched PubMed, Chinese National Knowledge Infrastructure and Wanfang databases for selecting pharmacogenetics-based warfarin dosing models. Patients with mechanic heart valve replacement were consecutively recruited between March 2012 and July 2012. The predicted warfarin dose of each patient was calculated and compared with the observed initial and stable warfarin doses. The percentage of patients whose predicted dose fell within 20% of their actual therapeutic dose (percentage within 20%), and the mean absolute error (MAE) were utilized to evaluate the predictive accuracy of all the selected algorithms. Results A total of 8 algorithms including Du, Huang, Miao, Wei, Zhang, Lou, Gage, and International Warfarin Pharmacogenetics Consortium (IWPC) model, were tested in 181 patients. The MAE of the Gage, IWPC and 6 Han-Chinese pharmacogenetics-based warfarin dosing algorithms was less than 0.6 mg/day in accuracy and the percentage within 20% exceeded 45% in all of the selected models in both the initial and the stable treatment stages. When patients were stratified according to the warfarin dose range, all of the equations demonstrated better performance in the ideal-dose range (1.88–4.38 mg/day) than the low-dose range (<1.88 mg/day). Among the 8 algorithms compared, the algorithms of Wei, Huang, and Miao showed a lower MAE and higher percentage within 20% in both the initial and the stable warfarin dose prediction and in the low-dose and the ideal-dose ranges. Conclusions All of the selected pharmacogenetics-based warfarin dosing regimens performed similarly in our cohort. However, the algorithms of Wei, Huang, and Miao showed a better potential for warfarin prediction in the initial and the stable treatment phases in Han-Chinese patients undertaking mechanic heart valve replacement. PMID:24728385
Zhao, Li; Chen, Chunxia; Li, Bei; Dong, Li; Guo, Yingqiang; Xiao, Xijun; Zhang, Eryong; Qin, Li
2014-01-01
To study the performance of pharmacogenetics-based warfarin dosing algorithms in the initial and the stable warfarin treatment phases in a cohort of Han-Chinese patients undertaking mechanic heart valve replacement. We searched PubMed, Chinese National Knowledge Infrastructure and Wanfang databases for selecting pharmacogenetics-based warfarin dosing models. Patients with mechanic heart valve replacement were consecutively recruited between March 2012 and July 2012. The predicted warfarin dose of each patient was calculated and compared with the observed initial and stable warfarin doses. The percentage of patients whose predicted dose fell within 20% of their actual therapeutic dose (percentage within 20%), and the mean absolute error (MAE) were utilized to evaluate the predictive accuracy of all the selected algorithms. A total of 8 algorithms including Du, Huang, Miao, Wei, Zhang, Lou, Gage, and International Warfarin Pharmacogenetics Consortium (IWPC) model, were tested in 181 patients. The MAE of the Gage, IWPC and 6 Han-Chinese pharmacogenetics-based warfarin dosing algorithms was less than 0.6 mg/day in accuracy and the percentage within 20% exceeded 45% in all of the selected models in both the initial and the stable treatment stages. When patients were stratified according to the warfarin dose range, all of the equations demonstrated better performance in the ideal-dose range (1.88-4.38 mg/day) than the low-dose range (<1.88 mg/day). Among the 8 algorithms compared, the algorithms of Wei, Huang, and Miao showed a lower MAE and higher percentage within 20% in both the initial and the stable warfarin dose prediction and in the low-dose and the ideal-dose ranges. All of the selected pharmacogenetics-based warfarin dosing regimens performed similarly in our cohort. However, the algorithms of Wei, Huang, and Miao showed a better potential for warfarin prediction in the initial and the stable treatment phases in Han-Chinese patients undertaking mechanic heart valve replacement.
Sánchez-Doblado, F; Andreo, P; Capote, R; Leal, A; Perucha, M; Arráns, R; Núñez, L; Mainegra, E; Lagares, J I; Carrasco, E
2003-07-21
Absolute dosimetry with ionization chambers of the narrow photon fields used in stereotactic techniques and IMRT beamlets is constrained by lack of electron equilibrium in the radiation field. It is questionable that stopping-power ratio in dosimetry protocols, obtained for broad photon beams and quasi-electron equilibrium conditions, can be used in the dosimetry of narrow fields while keeping the uncertainty at the same level as for the broad beams used in accelerator calibrations. Monte Carlo simulations have been performed for two 6 MV clinical accelerators (Elekta SL-18 and Siemens Mevatron Primus), equipped with radiosurgery applicators and MLC. Narrow circular and Z-shaped on-axis and off-axis fields, as well as broad IMRT configured beams, have been simulated together with reference 10 x 10 cm2 beams. Phase-space data have been used to generate 3D dose distributions which have been compared satisfactorily with experimental profiles (ion chamber, diodes and film). Photon and electron spectra at various depths in water have been calculated, followed by Spencer-Attix (delta = 10 keV) stopping-power ratio calculations which have been compared to those used in the IAEA TRS-398 code of practice. For water/air and PMMA/air stopping-power ratios, agreements within 0.1% have been obtained for the 10 x 10 cm2 fields. For radiosurgery applicators and narrow MLC beams, the calculated s(w,air) values agree with the reference within +/-0.3%, well within the estimated standard uncertainty of the reference stopping-power ratios (0.5%). Ionization chamber dosimetry of narrow beams at the photon qualities used in this work (6 MV) can therefore be based on stopping-power ratios data in dosimetry protocols. For a modulated 6 MV broad beam used in clinical IMRT, s(w,air) agrees within 0.1% with the value for 10 x 10 cm2, confirming that at low energies IMRT absolute dosimetry can also be based on data for open reference fields. At higher energies (24 MV) the difference in s(w,air) was up to 1.1%, indicating that the use of protocol data for narrow beams in such cases is less accurate than at low energies, and detailed calculations of the dosimetry parameters involved should be performed if similar accuracy to that of 6 MV is sought.
Krösser, S; Tillner, J; Fluck, M; Ungethüm, W; Wolna, P; Kovar, A
2007-05-01
Sarizotan is a 5-HTIA receptor agonist with high affinity for D3 and D4 receptors. Here we report the pharmacokinetic and tolerability results from four Phase 1 studies. Two single-dose (5 -25 mg, n = 25, 0.5 - 5 mg, n = 16) and two multiple-dose (10 and 20 mg b.i.d., n = 30, 5 mg b.i.d., n = 12) studies with orally administered sarizotan HCl were carried out in healthy subjects. Plasma sarizotan HCl concentrations were measured using a validated HPLC method and fluorescence or MS/MS detection. Pharmacokinetic parameters were obtained using standard non-compartmental methods. Sarizotan was rapidly absorbed, group-median times to reach maximum concentration (tmax) ranged from 0.5 -2.25 h after single doses and during steady state. Maximum plasma concentration (Cmax) and tmax were slightly dependent on formulation and food intake, whereas area under the curve (AUC) was unaffected by these factors. AUC and Cmax increased dose-proportionally over the tested dose range. Independently of dose and time, sarizotan HCl plasma concentrations declined polyexponentially with a terminal elimination half-life (t1/2) of 5 - 7 h. Accumulation factors corresponded to t1/2 values, and steady state was reached within 24 h. Plasma metabolite concentrations were considerably lower than those of the parent drug. The ratio metabolite AUC : parent drug AUC was time- and dose-independent for all three metabolites suggesting that the metabolism of sarizotan is non-saturable in the tested dose range. The pharmacokinetics of sarizotan were dose-proportional and time-independent for the dose range 0.5 -25 mg). The drug was well-tolerated by healthy subjects up to a single dose of 20 mg.
Radiation dose and magnification in pelvic X-ray: EOS™ imaging system versus plain radiographs.
Chiron, P; Demoulin, L; Wytrykowski, K; Cavaignac, E; Reina, N; Murgier, J
2017-12-01
In plain pelvic X-ray, magnification makes measurement unreliable. The EOS™ (EOS Imaging, Paris France) imaging system is reputed to reproduce patient anatomy exactly, with a lower radiation dose. This, however, has not been assessed according to patient weight, although both magnification and irradiation are known to vary with weight. We therefore conducted a prospective comparative study, to compare: (1) image magnification and (2) radiation dose between the EOS imaging system and plain X-ray. The EOS imaging system reproduces patient anatomy exactly, regardless of weight, unlike plain X-ray. A single-center comparative study of plain pelvic X-ray and 2D EOS radiography was performed in 183 patients: 186 arthroplasties; 104 male, 81 female; mean age 61.3±13.7years (range, 24-87years). Magnification and radiation dose (dose-area product [DAP]) were compared between the two systems in 186 hips in patients with a mean body-mass index (BMI) of 27.1±5.3kg/m 2 (range, 17.6-42.3kg/m 2 ), including 7 with morbid obesity. Mean magnification was zero using the EOS system, regardless of patient weight, compared to 1.15±0.05 (range, 1-1.32) on plain X-ray (P<10 -5 ). In patients with BMI<25, mean magnification on plain X-ray was 1.15±0.05 (range, 1-1.25) and, in patients with morbid obesity, 1.22±0.06 (range, 1.18-1.32). The mean radiation dose was 8.19±2.63dGy/cm 2 (range, 1.77-14.24) with the EOS system, versus 19.38±12.37dGy/cm 2 (range, 4.77-81.75) with plain X-ray (P<10 -4 ). For BMI >40, mean radiation dose was 9.36±2.57dGy/cm 2 (range, 7.4-14.2) with the EOS system, versus 44.76±22.21 (range, 25.2-81.7) with plain X-ray. Radiation dose increased by 0.20dGy with each extra BMI point for the EOS system, versus 0.74dGy for plain X-ray. Magnification did not vary with patient weight using the EOS system, unlike plain X-ray, and radiation dose was 2.5-fold lower. 3, prospective case-control study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moore, Bria M.; Brady, Samuel L., E-mail: samuel.brady@stjude.org; Kaufman, Robert A.
Purpose: To investigate the correlation of size-specific dose estimate (SSDE) with absorbed organ dose, and to develop a simple methodology for estimating patient organ dose in a pediatric population (5–55 kg). Methods: Four physical anthropomorphic phantoms representing a range of pediatric body habitus were scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations to determine absolute organ dose. Phantom absolute organ dose was divided by phantom SSDE to determine correlation between organ dose and SSDE. Organ dose correlation factors (CF{sub SSDE}{sup organ}) were then multiplied by patient-specific SSDE to estimate patient organ dose. Themore » CF{sub SSDE}{sup organ} were used to retrospectively estimate individual organ doses from 352 chest and 241 abdominopelvic pediatric CT examinations, where mean patient weight was 22 kg ± 15 (range 5–55 kg), and mean patient age was 6 yrs ± 5 (range 4 months to 23 yrs). Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm; thus, showing appropriate scalability of the phantoms across the entire pediatric population in this study. IndividualCF{sub SSDE}{sup organ} were determined for a total of 23 organs in the chest and abdominopelvic region across nine weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7–1.4) and abdominopelvic region (average 0.9; range 0.7–1.3) was near unity. For organ/tissue that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1–0.4) for both the chest and abdominopelvic regions, respectively. A means to estimate patient organ dose was demonstrated. Calculated patient organ dose, using patient SSDE and CF{sub SSDE}{sup organ}, was compared to previously published pediatric patient doses that accounted for patient size in their dose calculation, and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusions: For organs fully covered within the scan volume, the average correlation of SSDE and organ absolute dose was found to be better than ±10%. In addition, this study provides a complete list of organ dose correlation factors (CF{sub SSDE}{sup organ}) for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE.« less
Method and Apparatus for Improving the Resolution of Digitally Sampled Analog Data
NASA Technical Reports Server (NTRS)
Liaghati, Amir L. (Inventor)
2017-01-01
A system and method is described for converting an analog signal into a digital signal. The gain and offset of an ADC is dynamically adjusted so that the N-bits of input data are assigned to a narrower channel instead of the entire input range of the ADC. This provides greater resolution in the range of interest without generating longer digital data strings.
Low-Energy, Hydrogen-Free Method of Diamond Synthesis
NASA Technical Reports Server (NTRS)
Varshney, Deepak (Inventor); Morell, Gerardo (Inventor); Weiner, Brad R. (Inventor); Makarov, Vladimir (Inventor)
2013-01-01
Diamond thin films were deposited on copper substrate by the Vapor Solid (VS) deposition method using a mixture of fullerene C(sub 60) and graphite as the source material. The deposition took place only when the substrate was kept in a narrow temperature range of approximately 550-650 C. Temperatures below and above this range results in the deposition of fullerenes and other carbon compounds, respectively.
ERIC Educational Resources Information Center
Strimaitis, Anna M.; Southerland, Sherry A.; Sampson, Victor; Enderle, Patrick; Grooms, Jonathon
2017-01-01
This study examines what students enrolled in the honors and general sections of a high school biology course offered at the same school learn when they have an opportunity to participate in a broad or narrow range of science practices during their laboratory experiences. The results of our analysis suggest that the students enrolled in the…
Thermoluminescence glow-curve characteristics of LiF phosphors at high doses of gamma radiation
NASA Astrophysics Data System (ADS)
Benny, P. G.; Khader, S. A.; Sarma, K. S. S.
2013-05-01
High doses of ionising radiation are becoming increasingly common for radiation-processing applications of various medical, agricultural and polymer products using gamma and electron beams. The objective of this work was to study thermoluminescence (TL) glow-curve characteristics of commonly used commercial LiF TL phosphors at high doses of radiation with a view to use them in dosimetry of radiation-processing applications. The TL properties of TLD 100 and 700 phosphors, procured from the Thermo-Scientific (previously Harshaw) company, have been studied in the dose range of 1-60 kGy. The shift in glow peaks was observed in this dose range. Integral TL responses of TLD 100 and TLD 700 were found to decrease as a linear function of dose in the range of 5-50 kGy. The paper describes initial results related to the glow-curve characteristics of these phosphors.
Gotanda, Tatsuhiro; Katsuda, Toshizo; Gotanda, Rumi; Kuwano, Tadao; Akagawa, Takuya; Tanki, Nobuyoshi; Tabuchi, Akihiko; Shimono, Tetsunori; Kawaji, Yasuyuki
2016-01-01
Radiochromic film dosimeters have a disadvantage in comparison with an ionization chamber in that the dosimetry process is time-consuming for creating a density-absorbed dose calibration curve. The purpose of this study was the development of a simplified method of creating a density-absorbed dose calibration curve from radiochromic film within a short time. This simplified method was performed using Gafchromic EBT3 film with a low energy dependence and step-shaped Al filter. The simplified method was compared with the standard method. The density-absorbed dose calibration curves created using the simplified and standard methods exhibited approximately similar straight lines, and the gradients of the density-absorbed dose calibration curves were -32.336 and -33.746, respectively. The simplified method can obtain calibration curves within a much shorter time compared to the standard method. It is considered that the simplified method for EBT3 film offers a more time-efficient means of determining the density-absorbed dose calibration curve within a low absorbed dose range such as the diagnostic range.
Gotanda, Tatsuhiro; Katsuda, Toshizo; Gotanda, Rumi; Kuwano, Tadao; Akagawa, Takuya; Tanki, Nobuyoshi; Tabuchi, Akihiko; Shimono, Tetsunori; Kawaji, Yasuyuki
2016-01-01
Radiochromic film dosimeters have a disadvantage in comparison with an ionization chamber in that the dosimetry process is time-consuming for creating a density-absorbed dose calibration curve. The purpose of this study was the development of a simplified method of creating a density-absorbed dose calibration curve from radiochromic film within a short time. This simplified method was performed using Gafchromic EBT3 film with a low energy dependence and step-shaped Al filter. The simplified method was compared with the standard method. The density-absorbed dose calibration curves created using the simplified and standard methods exhibited approximately similar straight lines, and the gradients of the density-absorbed dose calibration curves were −32.336 and −33.746, respectively. The simplified method can obtain calibration curves within a much shorter time compared to the standard method. It is considered that the simplified method for EBT3 film offers a more time-efficient means of determining the density-absorbed dose calibration curve within a low absorbed dose range such as the diagnostic range. PMID:28144120
Scanning Shack-Hartmann wavefront sensor
NASA Astrophysics Data System (ADS)
Molebny, Vasyl V.
2004-09-01
Criss-crossing of focal images is the cause of a narrow dynamic range in Shack-Hartmann sensors. Practically, aberration range wider than +/-3 diopters can not be measured. A method has been proposed for ophthalmologic applications using a rarefied lenslet array through which a wave front is projected with the successive step-by-step changing of the global tilt. The data acquired in each step are accumulated and processed. In experimental setup, a doubled dynamic range was achieved with four steps of wave front tilting.
Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu
2005-07-01
We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (microg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r=0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r=0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA.
Gafchromic EBT-XD film: Dosimetry characterization in high-dose, volumetric-modulated arc therapy.
Miura, Hideharu; Ozawa, Shuichi; Hosono, Fumika; Sumida, Naoki; Okazue, Toshiya; Yamada, Kiyoshi; Nagata, Yasushi
2016-11-08
Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-dose volumetric-modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0-4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter-free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose-rate dependence. For clinical examinations, we compared the dose distribu-tion measured with EBT-XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT-XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ~ 3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ~ 1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ~ 1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film- measured and treatment planning system (TPS)-calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%. © 2016 The Authors.
Emission study on the gamma-ray irradiation effects on the ferroelectric Pb(Zr,Ti)O3 thin films
NASA Astrophysics Data System (ADS)
Lee, Yunsang; Lim, Junwhi; Yang, Sun A.; Bu, S. D.
We investigated the photoluminescence of the gammy-ray irradiated Pb(Zr,Ti)O3 (PZT) thin films with the various total doses up to 1000 kGy. The PZT thin films were prepared on the Pt/Ti/SiO2/Si substrates by using a sol-gel method with a spin-coating process. It was found that the visible emission emerges near 550 nm with the gamma-ray irradiation. The intensity of the emission increased with the increasing dose amount. The spectral feature of the gamma-ray induced emission was quite narrow, which was distinguished from that formed by normal defects such as oxygen vacancy. We suggest that the gamma-ray irradiation should generate a specific type of defect state inside the PZT films, which could be detected by the low temperature photoluminescence spectroscopy.
NASA Astrophysics Data System (ADS)
Lim, Junhwi; Lee, Y. S.; Yang, Sun A.; Bu, Sang Don
2016-06-01
We investigated the visible emission property of Pb(Zr,Ti)O3 (PZT) thin films irradiated with gammy-ray (γ-ray) irradiated at various total doses up to 1000 kGy. The PZT thin films were prepared on Pt/Ti/SiO2/Si substrates by using a sol-gel method with a spin-coating process. The visible emission was found to emerge near 550 nm upon γ-ray irradiation, and the intensity of the emission increased with increasing dose. The spectrum of the γ-ray-induced emission was quite narrow, which was quite different from that due to normal defects such as oxygen vacancies. We suggest that the γ-ray irradiation generates inside the PZT films a specific type of defect state that can be detected by using low-temperature photoluminescence spectroscopy.
Total Dose Effects on Bipolar Integrated Circuits at Low Temperature
NASA Technical Reports Server (NTRS)
Johnston, A. H.; Swimm, R. T.; Thorbourn, D. O.
2012-01-01
Total dose damage in bipolar integrated circuits is investigated at low temperature, along with the temperature dependence of the electrical parameters of internal transistors. Bandgap narrowing causes the gain of npn transistors to decrease far more at low temperature compared to pnp transistors, due to the large difference in emitter doping concentration. When irradiations are done at temperatures of -140 deg C, no damage occurs until devices are warmed to temperatures above -50 deg C. After warm-up, subsequent cooling shows that damage is then present at low temperature. This can be explained by the very strong temperature dependence of dispersive transport in the continuous-time-random-walk model for hole transport. For linear integrated circuits, low temperature operation is affected by the strong temperature dependence of npn transistors along with the higher sensitivity of lateral and substrate pnp transistors to radiation damage.
Ren, Xiaochen; Riley, James R.; Koleske, Daniel; ...
2015-07-14
In this study, atom probe tomography (APT) is used to characterize the influence of hydrogen dosing duringGaN barrier growth on the indium distribution of In xGa 1-xN quantum wells, and correlatedmicro-photoluminescence is used to measure changes in the emission spectrum and efficiency. We found that relative to the control growth, hydrogen dosing leads to a 50% increase in emission intensity arising from discontinuous quantum wells that are narrower, of lower indium content, and with more abrupt interfaces. Additionally, simulations of carrier distributions based on APT composition profiles indicate that the greater carrier confinement leads to an increased radiative recombination rate.more » Furthermore, APT analysis of quantum well profiles enables refinement of x-ray diffractionanalysis for more accurate nondestructive measurements of composition.« less
Genetics Home Reference: DNMT3A overgrowth syndrome
... eyes (narrowed palpebral fissures). Additionally, the upper front teeth are often larger than normal. Intellectual disability in DNMT3A overgrowth syndrome ranges from mild to severe. Individuals may have features of autism spectrum disorder , which are characterized by impaired communication ...
The U.S. Media: Supermarket or Assembly Line?
ERIC Educational Resources Information Center
Bagdikian, Ben H.
1985-01-01
Considers whether the media as a whole provide a rich marketplace of ideas. Concludes that the range of ideas and information is relatively narrow due to the nature of ownership and media economics, resulting in a homogenization of content. (PD)
SUBCELLULAR PHARMACOKINETICS AND ITS POTENTIAL FOR LIBRARY FOCUSING (R826652)
Subcellular pharmacokinetics (SP) optimizes biology-related factors in the design of libraries for high throughput screening by defining comparatively narrow ranges of properties (lipophilicity, amphiphilicity, acidity, reactivity, 3D-structural features) of t...
Mukhopadhyay, Pranab K; Gupta, Pradeep K; Singh, Amarjeet; Sharma, Sunil K; Bindra, Kushvinder S; Oak, Shrikant M
2014-05-01
A multimode interference filter with narrow transmission bandwidth and large self-imaging wavelength interval is constructed and implemented in an ytterbium doped fiber laser in all-fiber format for broad wavelength tunability as well as narrow spectral width of the output beam. The peak transmission wavelength of the multimode interference filter was tuned with the help of a standard in-fiber polarization controller. With this simple mechanism more than 30 nm (1038 nm-1070 nm) tuning range is demonstrated. The spectral width of the output beam from the laser was measured to be 0.05 nm.
NASA Astrophysics Data System (ADS)
Mukhopadhyay, Pranab K.; Gupta, Pradeep K.; Singh, Amarjeet; Sharma, Sunil K.; Bindra, Kushvinder S.; Oak, Shrikant M.
2014-05-01
A multimode interference filter with narrow transmission bandwidth and large self-imaging wavelength interval is constructed and implemented in an ytterbium doped fiber laser in all-fiber format for broad wavelength tunability as well as narrow spectral width of the output beam. The peak transmission wavelength of the multimode interference filter was tuned with the help of a standard in-fiber polarization controller. With this simple mechanism more than 30 nm (1038 nm-1070 nm) tuning range is demonstrated. The spectral width of the output beam from the laser was measured to be 0.05 nm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piot, P.; Maxwell, T. J.; Accelerator Physics Center, Fermi National Accelerator Laboratory, Batavia, Illinois 60510
2011-06-27
We experimentally demonstrate the production of narrow-band ({delta}f/f{approx_equal}20% at f{approx_equal}0.5THz) transition radiation with tunable frequency over [0.37, 0.86] THz. The radiation is produced as a train of sub-picosecond relativistic electron bunches transits at the vacuum-aluminum interface of an aluminum converter screen. The bunch train is generated via a transverse-to-longitudinal phase space exchange technique. We also show a possible application of modulated beams to extend the dynamical range of a popular bunch length diagnostic technique based on the spectral analysis of coherent radiation.
Investigation of narrow-band thermal emission from intersubband transitions in quantum wells
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Zoysa, M.; Hakubi Center, Kyoto University, Yoshida, Kyoto 606-8501; Asano, T.
2015-09-14
We investigate thermal emission from n-doped GaAs/AlGaAs quantum wells (QWs). Emission peaks with Lorentzian shapes (linewidth 11∼19 meV) that reflect transitions between the first and second conduction subbands are observed in the mid-infrared range. It is demonstrated that the emission characteristics can be tuned by modifying the QW parameters. The peak emissivity is increased from 0.3 to 0.9 by modifying the doping density, and the peak wavelength is tuned from 6 to 10 μm by changing the well width. The obtained results are useful for the design of narrow-band thermal emitters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukhopadhyay, Pranab K., E-mail: pkm@rrcat.gov.in; Gupta, Pradeep K.; Singh, Amarjeet
2014-05-15
A multimode interference filter with narrow transmission bandwidth and large self-imaging wavelength interval is constructed and implemented in an ytterbium doped fiber laser in all-fiber format for broad wavelength tunability as well as narrow spectral width of the output beam. The peak transmission wavelength of the multimode interference filter was tuned with the help of a standard in-fiber polarization controller. With this simple mechanism more than 30 nm (1038 nm–1070 nm) tuning range is demonstrated. The spectral width of the output beam from the laser was measured to be 0.05 nm.
The nonuniformity of antibody distribution in the kidney and its influence on dosimetry.
Flynn, Aiden A; Pedley, R Barbara; Green, Alan J; Dearling, Jason L; El-Emir, Ethaar; Boxer, Geoffrey M; Boden, Robert; Begent, Richard H J
2003-02-01
The therapeutic efficacy of radiolabeled antibody fragments can be limited by nephrotoxicity, particularly when the kidney is the major route of extraction from the circulation. Conventional dose estimates in kidney assume uniform dose deposition, but we have shown increased antibody localization in the cortex after glomerular filtration. The purpose of this study was to measure the radioactivity in cortex relative to medulla for a range of antibodies and to assess the validity of the assumption of uniformity of dose deposition in the whole kidney and in the cortex for these antibodies with a range of radionuclides. Storage phosphor plate technology (radioluminography) was used to acquire images of the distributions of a range of antibodies of various sizes, labeled with 125I, in kidney sections. This allowed the calculation of the antibody concentration in the cortex relative to the medulla. Beta-particle point dose kernels were then used to generate the dose-rate distributions from 14C, 131I, 186Re, 32P and 90Y. The correlation between the actual dose-rate distribution and the corresponding distribution calculated assuming uniform antibody distribution throughout the kidney was used to test the validity of estimating dose by assuming uniformity in the kidney and in the cortex. There was a strong inverse relationship between the ratio of the radioactivity in the cortex relative to that in the medulla and the antibody size. The nonuniformity of dose deposition was greatest with the smallest antibody fragments but became more uniform as the range of the emissions from the radionuclide increased. Furthermore, there was a strong correlation between the actual dose-rate distribution and the distribution when assuming a uniform source in the kidney for intact antibodies along with medium- to long-range radionuclides, but there was no correlation for small antibody fragments with any radioisotope or for short-range radionuclides with any antibody. However, when the cortex was separated from the whole kidney, the correlation between the actual dose-rate distribution and the assumed dose-rate distribution, if the source was uniform, increased significantly. During radioimmunotherapy, the extent of nonuniformity of dose deposition in the kidney depends on the properties of the antibody and radionuclide. For dosimetry estimates, the cortex should be taken as a separate source region when the radiopharmaceutical is small enough to be filtered by the glomerulus.
Lee, Eunsol; Goo, Hyun Woo; Lee, Jae-Yeong
2015-08-01
It is necessary to develop a mechanism to estimate and analyze cumulative radiation risks from multiple CT exams in various clinical scenarios in children. To identify major contributors to high cumulative CT dose estimates using actual dose-length product values collected for 5 years in children. Between August 2006 and July 2011 we reviewed 26,937 CT exams in 13,803 children. Among them, we included 931 children (median age 3.5 years, age range 0 days-15 years; M:F = 533:398) who had 5,339 CT exams. Each child underwent at least three CT scans and had accessible radiation dose reports. Dose-length product values were automatically extracted from DICOM files and we used recently updated conversion factors for age, gender, anatomical region and tube voltage to estimate CT radiation dose. We tracked the calculated CT dose estimates to obtain a 5-year cumulative value for each child. The study population was divided into three groups according to the cumulative CT dose estimates: high, ≥30 mSv; moderate, 10-30 mSv; and low, <10 mSv. We reviewed clinical data and CT protocols to identify major contributors to high and moderate cumulative CT dose estimates. Median cumulative CT dose estimate was 5.4 mSv (range 0.5-71.1 mSv), and median number of CT scans was 4 (range 3-36). High cumulative CT dose estimates were most common in children with malignant tumors (57.9%, 11/19). High frequency of CT scans was attributed to high cumulative CT dose estimates in children with ventriculoperitoneal shunt (35 in 1 child) and malignant tumors (range 18-49). Moreover, high-dose CT protocols, such as multiphase abdomen CT (median 4.7 mSv) contributed to high cumulative CT dose estimates even in children with a low number of CT scans. Disease group, number of CT scans, and high-dose CT protocols are major contributors to higher cumulative CT dose estimates in children.
Dose dependence of helium bubble formation in nano-engineered SiC at 700 °C
Chen, Chien -Hung; Zhang, Yanwen; Wang, Yongqiang; ...
2016-02-03
Knowledge of radiation-induced helium bubble nucleation and growth in SiC is essential for applications in fusion and fission environments. Here we report the evolution of microstructure in nano-engineered (NE) 3C SiC, pre-implanted with helium, under heavy ion irradiation at 700 °C up to doses of 30 displacements per atom (dpa). Elastic recoil detection analysis confirms that the as-implanted helium depth profile does not change under irradiation to 30 dpa at 700 °C. While the helium bubble size distribution becomes narrower with increasing dose, the average size of bubbles remains unchanged and the density of bubbles increases somewhat with dose. Thesemore » results are consistent with a long helium bubble incubation process under continued irradiation at 700 °C up to 30 dpa, similar to that reported under dual and triple beam irradiation at much higher temperatures. The formation of bubbles at this low temperature is enhanced by the nano-layered stacking fault structure in the NE SiC, which enhances point defect mobility parallel to the stacking faults. Here, this stacking fault structure is stable at 700 °C up to 30 dpa and suppresses the formation of dislocation loops normally observed under these irradiation conditions.« less
Analysis of patient CT dose data using virtualdose
NASA Astrophysics Data System (ADS)
Bennett, Richard
X-ray computer tomography has many benefits to medical and research applications. Recently, over the last decade CT has had a large increase in usage in hospitals and medical diagnosis. In pediatric care, from 2000 to 2006, abdominal CT scans increased by 49 % and chest CT by 425 % in the emergency room (Broder 2007). Enormous amounts of effort have been performed across multiple academic and government groups to determine an accurate measure of organ dose to patients who undergo a CT scan due to the inherent risks with ionizing radiation. Considering these intrinsic risks, CT dose estimating software becomes a necessary tool that health care providers and radiologist must use to determine many metrics to base the risks versus rewards of having an x-ray CT scan. This thesis models the resultant organ dose as body mass increases for patients with all other related scan parameters fixed. In addition to this,this thesis compares a modern dose estimating software, VirtualDose CT to two other programs, CT-Expo and ImPACT CT. The comparison shows how the software's theoretical basis and the phantom they use to represent the human body affect the range of results in organ dose. CT-Expo and ImPACT CT dose estimating software uses a different model for anatomical representation of the organs in the human body and the results show how that approach dramatically changes the outcome. The results categorizes four datasets as compared to the three software types where the appropriate phantom was available. Modeling was done to simulate chest abdominal pelvis scans and whole body scans. Organ dose difference versus body mass index shows as body mass index (BMI) ranges from 23.5 kg/m 2 to 45 kg/m2 the amount of organ dose also trends a percent change from -4.58 to -176.19 %. Comparing organ dose difference with increasing x-ray tube potential from 120 kVp to 140 kVp the percent change in organ dose increases from 55 % to 65 % across all phantoms. In comparing VirtualDose to CT-Expo for organ dose difference versus age, male phantoms show percent difference of -19 % to 25 % for various organs minus bone surface and breast tissues results. Finally, for organ dose difference across all software for average adult phantom the results range from -45 % to 6 % in the comparison of ImPACT CT to VirtualDose and -27 % to 66 % for the comparison of CT-Expo to VirtualDose. In the comparison for increased BMI (done only in VirtualDose), results show that with all other parameters fixed, the organ dose goes down as BMI increases, which is due to the increase in adipose tissue and bulk of the patient model. The range of results when comparing all the three softwares have a wide range, in some cases greater than 150 %, it is evident that using a different anatomical basis for the human phantom and the theoretical basis for the dose estimation will cause fluctuation in the results. Therefore, choosing the software with the most accurate human phantom will provide a closer range to the true dose to the organ.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liebl, Jakob, E-mail: jakob.liebl@medaustron.at; Francis H. Burr Proton Therapy Center, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114; Department of Therapeutic Radiology and Oncology, Medical University of Graz, 8036 Graz
2014-09-15
Purpose: Proton radiotherapy allows radiation treatment delivery with high dose gradients. The nature of such dose distributions increases the influence of patient positioning uncertainties on their fidelity when compared to photon radiotherapy. The present work quantitatively analyzes the influence of setup uncertainties on proton range and dose distributions. Methods: Thirty-eight clinical passive scattering treatment fields for small lesions in the head were studied. Dose distributions for shifted and rotated patient positions were Monte Carlo-simulated. Proton range uncertainties at the 50%- and 90%-dose falloff position were calculated considering 18 arbitrary combinations of maximal patient position shifts and rotations for two patientmore » positioning methods. Normal tissue complication probabilities (NTCPs), equivalent uniform doses (EUDs), and tumor control probabilities (TCPs) were studied for organs at risk (OARs) and target volumes of eight patients. Results: The authors identified a median 1σ proton range uncertainty at the 50%-dose falloff of 2.8 mm for anatomy-based patient positioning and 1.6 mm for fiducial-based patient positioning as well as 7.2 and 5.8 mm for the 90%-dose falloff position, respectively. These range uncertainties were correlated to heterogeneity indices (HIs) calculated for each treatment field (38% < R{sup 2} < 50%). A NTCP increase of more than 10% (absolute) was observed for less than 2.9% (anatomy-based positioning) and 1.2% (fiducial-based positioning) of the studied OARs and patient shifts. For target volumes TCP decreases by more than 10% (absolute) occurred in less than 2.2% of the considered treatment scenarios for anatomy-based patient positioning and were nonexistent for fiducial-based patient positioning. EUD changes for target volumes were up to 35% (anatomy-based positioning) and 16% (fiducial-based positioning). Conclusions: The influence of patient positioning uncertainties on proton range in therapy of small lesions in the human brain as well as target and OAR dosimetry were studied. Observed range uncertainties were correlated with HIs. The clinical practice of using multiple fields with smeared compensators while avoiding distal OAR sparing is considered to be safe.« less
Liebl, Jakob; Paganetti, Harald; Zhu, Mingyao; Winey, Brian A.
2014-01-01
Purpose: Proton radiotherapy allows radiation treatment delivery with high dose gradients. The nature of such dose distributions increases the influence of patient positioning uncertainties on their fidelity when compared to photon radiotherapy. The present work quantitatively analyzes the influence of setup uncertainties on proton range and dose distributions. Methods: Thirty-eight clinical passive scattering treatment fields for small lesions in the head were studied. Dose distributions for shifted and rotated patient positions were Monte Carlo-simulated. Proton range uncertainties at the 50%- and 90%-dose falloff position were calculated considering 18 arbitrary combinations of maximal patient position shifts and rotations for two patient positioning methods. Normal tissue complication probabilities (NTCPs), equivalent uniform doses (EUDs), and tumor control probabilities (TCPs) were studied for organs at risk (OARs) and target volumes of eight patients. Results: The authors identified a median 1σ proton range uncertainty at the 50%-dose falloff of 2.8 mm for anatomy-based patient positioning and 1.6 mm for fiducial-based patient positioning as well as 7.2 and 5.8 mm for the 90%-dose falloff position, respectively. These range uncertainties were correlated to heterogeneity indices (HIs) calculated for each treatment field (38% < R2 < 50%). A NTCP increase of more than 10% (absolute) was observed for less than 2.9% (anatomy-based positioning) and 1.2% (fiducial-based positioning) of the studied OARs and patient shifts. For target volumes TCP decreases by more than 10% (absolute) occurred in less than 2.2% of the considered treatment scenarios for anatomy-based patient positioning and were nonexistent for fiducial-based patient positioning. EUD changes for target volumes were up to 35% (anatomy-based positioning) and 16% (fiducial-based positioning). Conclusions: The influence of patient positioning uncertainties on proton range in therapy of small lesions in the human brain as well as target and OAR dosimetry were studied. Observed range uncertainties were correlated with HIs. The clinical practice of using multiple fields with smeared compensators while avoiding distal OAR sparing is considered to be safe. PMID:25186386
Qu, Xing-min; Li, Gang; Ludlow, John B; Zhang, Zu-yan; Ma, Xu-chen
2010-12-01
The aim of this study was to compare effective doses resulting from different scan protocols for cone-beam computerized tomography (CBCT) using International Commission on Radiological Protection (ICRP) 1990 and 2007 calculations of dose. Average tissue-absorbed dose, equivalent dose, and effective dose for a ProMax 3D CBCT with different dental protocols were calculated using thermoluminescent dosimeter chips in a human equivalent phantom. Effective doses were derived using ICRP 1990 and the superseding 2007 recommendations. Effective doses (ICRP 2007) for default patient sizes from small to large ranged from 102 to 298 μSv. The coefficient of determination (R(2)) between tube current and effective dose (ICRP 2007) was 0.90. When scanning with lower resolution settings, the effective doses were reduced significantly (P < .05). ProMax 3D can provide a wide range of radiation dose levels. Reduction in radiation dose can be achieved when using lower settings of exposure parameters. Copyright © 2010 Mosby, Inc. All rights reserved.
Dalton, Hillary A; Wood, Benjamin J; Widowski, Tina M; Guerin, Michele T; Torrey, Stephanie
2017-01-01
The objective of this study was to assess beak shape variation in domestic turkeys (Meleagris gallopavo) and determine the effects of age, sex, and beak size on beak shape variation using geometric morphometrics. Dorsal and right lateral images were taken of 2442 turkeys at 6 and 18.5 weeks of age. Landmarks were digitized in tpsDig in three analyses of the dorsal upper mandible, lateral upper mandible, and lateral lower mandible shape of each turkey at both ages. The coordinate data were then subjected to a principal components analysis (PCA), multivariate regression, and a canonical variates analysis (CVA) with a Procrustes ANOVA in MorphoJ. For the dorsal images, three principal components (PCs) showed beak shape variation ranged from long, narrow, and pointed to short, wide, and blunt upper mandibles at both ages (6 weeks: 95.36%, 18.5 weeks: 92.21%). Three PCs showed the lateral upper mandible shape variation ranged from long, wide beaks with long, curved beak tips to short, narrow beaks with short, pointed beak tips at both ages (6 weeks: 94.91%, 18.5 weeks: 94.33%). Three PCs also explained 97.80% (6 weeks) and 97.11% (18.5 weeks) of the lateral lower mandible shape variation ranging from wide and round to narrow and thin lower mandibles with superior/inferior beak tip shifts. Beak size accounted for varying proportions of the beak shape variation (0.96-54.76%; P < 0.0001) in the three analyses of each age group. For all the analyses, the CVA showed sexual dimorphism in beak shape (P < 0.0001) with female upper mandibles appearing wider and blunter dorsally with long, curved beak tips laterally. Whereas male turkey upper mandibles had a narrow, pointed dorsal appearance and short, pointed beak tips laterally. Future applications of beak shape variability could have a genetic and welfare value by incorporating beak shape variation to select for specific turkey beak phenotypes as an alternative to beak treatment.
Widowski, Tina M.; Guerin, Michele T.
2017-01-01
The objective of this study was to assess beak shape variation in domestic turkeys (Meleagris gallopavo) and determine the effects of age, sex, and beak size on beak shape variation using geometric morphometrics. Dorsal and right lateral images were taken of 2442 turkeys at 6 and 18.5 weeks of age. Landmarks were digitized in tpsDig in three analyses of the dorsal upper mandible, lateral upper mandible, and lateral lower mandible shape of each turkey at both ages. The coordinate data were then subjected to a principal components analysis (PCA), multivariate regression, and a canonical variates analysis (CVA) with a Procrustes ANOVA in MorphoJ. For the dorsal images, three principal components (PCs) showed beak shape variation ranged from long, narrow, and pointed to short, wide, and blunt upper mandibles at both ages (6 weeks: 95.36%, 18.5 weeks: 92.21%). Three PCs showed the lateral upper mandible shape variation ranged from long, wide beaks with long, curved beak tips to short, narrow beaks with short, pointed beak tips at both ages (6 weeks: 94.91%, 18.5 weeks: 94.33%). Three PCs also explained 97.80% (6 weeks) and 97.11% (18.5 weeks) of the lateral lower mandible shape variation ranging from wide and round to narrow and thin lower mandibles with superior/inferior beak tip shifts. Beak size accounted for varying proportions of the beak shape variation (0.96–54.76%; P < 0.0001) in the three analyses of each age group. For all the analyses, the CVA showed sexual dimorphism in beak shape (P < 0.0001) with female upper mandibles appearing wider and blunter dorsally with long, curved beak tips laterally. Whereas male turkey upper mandibles had a narrow, pointed dorsal appearance and short, pointed beak tips laterally. Future applications of beak shape variability could have a genetic and welfare value by incorporating beak shape variation to select for specific turkey beak phenotypes as an alternative to beak treatment. PMID:28934330
Dipasquale, Giovanna; Nouet, Philippe; Rouzaud, Michel; Dubouloz, Angèle; Miralbell, Raymond; Zilli, Thomas
2014-06-01
To assess in vivo dose distribution using cone-beam computed tomography scans (CBCTs) and thermoluminescent dosimeters (TLDs) in patients with anal or rectal cancer treated with volumetric modulated arc therapy (VMAT). Intracavitary (IC) in vivo dosimetry (IVD) was performed in 11 patients using adapted endorectal probes containing TLDs, with extra measurements at the perianal skin (PS) for anal margin tumors. Measured doses were compared to calculated ones obtained from image fusion of CBCT with CT treatments plans. A total of 55 IC and 6 PS measurements were analyzed. IC TLD median planned and measured doses were 1.81 Gy (range, 0.25-2.02 Gy) and 1.82 Gy (range, 0.19-2.12 Gy), respectively. In comparison to the planned doses all IC TLD dose measurements differed by a median dose of 0.02 Gy (range, -0.11/+0.19 Gy, p=0.102) (median difference of 1.1%, range -6.1%/+10.6%). Overall, 95% of IC measurements were within ±7.7% of the expected percentage doses and only 1 value was above +10%. For PS measurements, only one was not within ±7.7% of expected values (i.e., -8.9%). Image guidance using CBCT for IVD with TLDs is helpful to validate the delivered doses in patients treated with VMAT for ano-rectal tumors. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Estimated ultraviolet radiation doses in wetlands in six national parks
Diamond, S.A.; Trenham, P.C.; Adams, Michael J.; Hossack, B.R.; Knapp, R.A.; Stark, L.; Bradford, D.; Corn, P.S.; Czarnowski, K.; Brooks, P.D.; Fagre, D.B.; Breen, B.; Dentenbeck, N.E.; Tonnessen, K.
2005-01-01
Ultraviolet-B radiation (UV-B, 280–320-nm wavelengths) doses were estimated for 1024 wetlands in six national parks: Acadia (Acadia), Glacier (Glacier), Great Smoky Mountains (Smoky), Olympic (Olympic), Rocky Mountain (Rocky), and Sequoia/Kings Canyon (Sequoia). Estimates were made using ground-based UV-B data (Brewer spectrophotometers), solar radiation models, GIS tools, field characterization of vegetative features, and quantification of DOC concentration and spectral absorbance. UV-B dose estimates were made for the summer solstice, at a depth of 1 cm in each wetland. The mean dose across all wetlands and parks was 19.3 W-h m−2 (range of 3.4–32.1 W-h m−2). The mean dose was lowest in Acadia (13.7 W-h m−2) and highest in Rocky (24.4 W-h m−2). Doses were significantly different among all parks. These wetland doses correspond to UV-B flux of 125.0 μW cm−2 (range 21.4–194.7 μW cm−2) based on a day length, averaged among all parks, of 15.5 h. Dissolved organic carbon (DOC), a key determinant of water-column UV-B flux, ranged from 0.6 (analytical detection limit) to 36.7 mg C L−1 over all wetlands and parks, and reduced potential maximal UV-B doses at 1-cm depth by 1%–87 %. DOC concentration, as well as its effect on dose, was lowest in Sequoia and highest in Acadia (DOC was equivalent in Acadia, Glacier, and Rocky). Landscape reduction of potential maximal UV-B doses ranged from zero to 77% and was lowest in Sequoia. These regional differences in UV-B wetland dose illustrate the importance of considering all aspects of exposure in evaluating the potential impact of UV-B on aquatic organisms.
Hard, Marjie L.; Mills, Richard J.; Sadler, Brian M.; Turncliff, Ryan Z.; Citrome, Leslie
2017-01-01
Abstract Background Aripiprazole lauroxil is an extended-release prodrug of aripiprazole for intramuscular injection, approved for schizophrenia treatment. We developed a population pharmacokinetic (PopPK) model to characterize aripiprazole lauroxil PK and evaluate dosing scenarios likely to be encountered in clinical practice. Methods Data from 616 patients with schizophrenia, collected from 5 clinical studies, were used to construct the PopPK model. The model was subsequently used to evaluate various dose levels and frequency and the impact of dosing delay on aripiprazole concentrations. Findings The results of the model indicate that aripiprazole is released into the systemic circulation after 5 to 6 days, and release continues for an additional 36 days. The slow increase in aripiprazole concentration after injection necessitates the coadministration of oral aripiprazole for 21 days with the first injection. Based on the PopPK model simulations, a dosing interval of 882 mg every 6 weeks results in aripiprazole concentrations that fall within the concentration range associated with the efficacious aripiprazole lauroxil dose range (441–882 mg dosed monthly). A 662-mg monthly dose also resulted in aripiprazole concentrations within the efficacious dose range. Aripiprazole lauroxil administration results in prolonged exposure, such that dose delays of 2 to 4 weeks, depending on the dose regimen, do not require oral aripiprazole supplementation upon resumption of dosing. Conclusions This PopPK model and model-based simulations were effective means for evaluating aripiprazole lauroxil dosing regimens and management of missed doses. Such analyses play an important role in determining the use of this long-acting antipsychotic in clinical practice. PMID:28350572
Tablet splitting of a narrow therapeutic index drug: a case with levothyroxine sodium.
Shah, Rakhi B; Collier, Jarrod S; Sayeed, Vilayat A; Bryant, Arthur; Habib, Muhammad J; Khan, Mansoor A
2010-09-01
Levothyroxine is a narrow therapeutic index, and to avoid adverse effect associated with under or excessive dosage, the dose response is carefully titrated. The tablets are marketed with a score providing an option to split. However, there are no systematic studies evaluating the effect of splitting on dose accuracy, and current study was undertaken to evaluate effects of splitting and potential causes for uniformity failures by measuring assay and content uniformity in whole and split tablets. Stability was evaluated by assaying drug for a period of 8 weeks. Effect of formulation factors on splittability was evaluated by a systematic investigation of formulation factors by preparing levothyroxine tablets in house by varying the type of excipients (binder, diluent, disintegrant, glidant) or by varying the processing factors (granulating liquid, mixing type, compression pressure). The tablets were analyzed using novel analytical tool such as near infrared chemical imaging to visualize the distribution of levothyroxine. Assay was not significantly different for whole versus split tablets irrespective of method of splitting (hand or splitter), and splitting also had no measurable impact on the stability. Split tablets either by hand or splitter showed higher rate of content uniformity failures as compared to whole tablets. Tablet splitter produced more fragmentation and, hence, more content uniformity and friability failures. Chemical imaging data revealed that the distribution of levothyroxine was heterogeneous and was dependent on type of binder and the process used in the manufacture of tablets. Splitting such tablets could prove detrimental if sub- or super-potency becomes an issue.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, J; Kino, A; Newman, B
2014-06-01
Purpose: To investigate the radiation dose for pediatric high pitch cardiac CTA Methods: A total of 14 cases were included in this study, with mean age of 6.2 years (ranges from 2 months to 15 years). Cardiac CTA was performed using a dual-source CT system (Definition Flash, Siemens). Tube voltage (70, 80 and 100kV) was chosen based on patient weight. All patients were scanned using a high-pitch spiral mode (pitch ranges from 2.5 to 3) with tube current modulation technique (CareDose4D, Siemens). For each case, the three dimensional dose distributions were calculated using a Monte Carlo software package (IMPACT-MC, CTmore » Image GmbH). Scanning parameters of each exam, including tube voltage, tube current, beamshaping filters, beam collimation, were defined in the Monte Carlo calculation. Tube current profile along projection angles was obtained from projection data of each tube, which included data within the over-scanning range along z direction. The volume of lungs was segmented out with CT images (3DSlicer). Lung doses of all patients were calculated and compared with CTDIvol, DLP, and SSDE. Results: The average (range) of CTDIvol, DLP and SSDE of all patients was 1.19 mGy (0.58 to 3.12mGy), 31.54 mGy*cm (12.56 to 99 mGy*cm), 2.26 mGy (1.19 to 6.24 mGy), respectively. Radiation dose to the lungs ranged from 0.83 to 4.18 mGy. Lung doses correlated with CTDIvol, DLP and SSDE with correlation coefficients(k) at 0.98, 0.93, and 0.99. However, for the cases with CTDIvol less than 1mGy, only SSDE preserved a strong correlation with lung doses (k=0.83), while much weaker correlations were found for CTDIvol (k=0.29) and DLP (k=-0.47). Conclusion: Lung doses to pediatric patients during Cardiac CTA were estimated. SSDE showed the most robust correlation with lung doses in contrast to CTDIvol and DLP.« less
Synthesis and characterization of mesoporous ZnS with narrow size distribution of small pores
NASA Astrophysics Data System (ADS)
Nistor, L. C.; Mateescu, C. D.; Birjega, R.; Nistor, S. V.
2008-08-01
Pure, nanocrystalline cubic ZnS forming a stable mesoporous structure was synthesized at room temperature by a non-toxic surfactant-assisted liquid liquid reaction, in the 9.5 10.5 pH range of values. The appearance of an X-ray diffraction (XRD) peak in the region of very small angles (˜ 2°) reveals the presence of a porous material with a narrow pore size distribution, but with an irregular arrangement of the pores, a so-called worm hole or sponge-like material. The analysis of the wide angle XRD diffractograms shows the building blocks to be ZnS nanocrystals with cubic structure and average diameter of 2 nm. Transmission electron microscopy (TEM) investigations confirm the XRD results; ZnS crystallites of 2.5 nm with cubic (blende) structure are the building blocks of the pore walls with pore sizes from 1.9 to 2.5 nm, and a broader size distribution for samples with smaller pores. Textural measurements (N2 adsorption desorption isotherms) confirm the presence of mesoporous ZnS with a narrow range of small pore sizes. The relatively lower surface area of around 100 m2/g is attributed to some remaining organic molecules, which are filling the smallest pores. Their presence, confirmed by IR spectroscopy, seems to be responsible for the high stability of the resulting mesoporous ZnS as well.
Analytical probabilistic proton dose calculation and range uncertainties
NASA Astrophysics Data System (ADS)
Bangert, M.; Hennig, P.; Oelfke, U.
2014-03-01
We introduce the concept of analytical probabilistic modeling (APM) to calculate the mean and the standard deviation of intensity-modulated proton dose distributions under the influence of range uncertainties in closed form. For APM, range uncertainties are modeled with a multivariate Normal distribution p(z) over the radiological depths z. A pencil beam algorithm that parameterizes the proton depth dose d(z) with a weighted superposition of ten Gaussians is used. Hence, the integrals ∫ dz p(z) d(z) and ∫ dz p(z) d(z)2 required for the calculation of the expected value and standard deviation of the dose remain analytically tractable and can be efficiently evaluated. The means μk, widths δk, and weights ωk of the Gaussian components parameterizing the depth dose curves are found with least squares fits for all available proton ranges. We observe less than 0.3% average deviation of the Gaussian parameterizations from the original proton depth dose curves. Consequently, APM yields high accuracy estimates for the expected value and standard deviation of intensity-modulated proton dose distributions for two dimensional test cases. APM can accommodate arbitrary correlation models and account for the different nature of random and systematic errors in fractionated radiation therapy. Beneficial applications of APM in robust planning are feasible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, L; Hu, W; Moyers, M
2015-06-15
Purpose: Positron-emitting isotope distributions can be used for the image fusion of the carbon ion planning CT and online target verification PETCT, after radiation in the same decay period,the relationship between the same target volume and the SUV value of different every single fraction dose can be found,then the range of SUV for the radiation target could be decided.So this online range also can provide reference for the correlation and consistency in planning target dose verification and evaluation for the clinical trial. Methods: The Rando head phantom can be used as real body,the 10cc cube volume target contouring is done,beammore » ISO Center depth is 7.6cm and the 90 degree fixed carbon ion beams should be delivered in single fraction effective dose of 2.5GyE,5GyE and 8GyE.After irradiation,390 seconds later the 30 minutes PET-CT scanning is performed,parameters are set to 50Kg virtual weight,0.05mCi activity.MIM Maestro is used for the image processing and fusion,five 16mm diameter SUV spheres have been chosen in the different direction in the target.The average SUV in target for different fraction dose can be found by software. Results: For 10cc volume target,390 seconds decay period,the Single fraction effective dose equal to 2.5Gy,Ethe SUV mean value is 3.42,the relative range is 1.72 to 6.83;Equal to 5GyE,SUV mean value is 9.946,the relative range is 7.016 to 12.54;Equal or above to 8GyE,SUV mean value is 20.496,the relative range is 11.16 to 34.73. Conclusion: Making an evaluation for accuracy of the dose distribution using the SUV range which is from the planning CT with after treatment online PET-CT fusion for the normal single fraction carbon ion treatment is available.Even to the plan which single fraction dose is above 2GyE,in the condition of other parameters all the same,the SUV range is linearly dependent with single fraction dose,so this method also can be used in the hyper-fraction treatment plan.« less
WE-A-17A-12: The Influence of Eye Plaque Design On Dose Distributions and Dose- Volume Histograms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aryal, P; Molloy, JA; Rivard, MJ
Purpose: To investigate the effect of slot design of the model EP917 plaque on dose distributions and dose-volume histograms (DVHs). Methods: The dimensions and orientation of the slots in EP917 plaques were measured. In the MCNP5 radiation simulation geometry, dose distributions on orthogonal planes and DVHs for a tumor and sclera were generated for comparisons. 27 slot designs and 13 plaques were evaluated and compared with the published literature and the Plaque Simulator clinical treatment planning system. Results: The dosimetric effect of the gold backing composition and mass density was < 3%. Slot depth, width, and length changed the centralmore » axis (CAX) dose distributions by < 1% per 0.1 mm in design variation. Seed shifts in the slot towards the eye and shifts of the {sup 125} I-coated Ag rod within the capsule had the greatest impact on CAX dose distribution, increasing by 14%, 9%, 4%, and 2.5% at 1, 2, 5, and 10 mm, respectively, from the inner sclera. Along the CAX, dose from the full plaque geometry using the measured slot design was 3.4% ± 2.3% higher than the manufacturer-provided geometry. D{sub 10} for the simulated tumor, inner sclera, and outer sclera for the measured plaque was also higher, but 9%, 10%, and 20%, respectively. In comparison to the measured plaque design, a theoretical plaque having narrow and deep slots delivered 30%, 37%, and 62% lower D{sub 10} doses to the tumor, inner sclera, and outer sclera, respectively. CAX doses at −1, 0, 1, and 2 mm were also lower by a factor of 2.6, 1.4, 1.23, and 1.13, respectively. Conclusion: The study identified substantial sensitivity of the EP917 plaque dose distributions to slot design. However, it did not identify substantial dosimetric variations based on radionuclide choice ({sup 125}I, {sup 103}Pd, or {sup 131}Cs). COMS plaques provided lower scleral doses with similar tumor dose coverage.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mead, H; St. Jude Children’s Research Hospital, Memphis, TN; Brady, S
Purpose: To discover if a previously published methodology for estimating patient-specific organ dose in a pediatric population (5–55kg) is translatable to the adult sized patient population (> 55 kg). Methods: An adult male anthropomorphic phantom was scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations in the chest and abdominopelvic regions to determine absolute organ dose. Organ-dose-to-SSDE correlation factors were developed by dividing individual phantom organ doses by SSDE of the phantom; where SSDE was calculated at the center of the scan volume of the chest and abdomen/pelvis separately. Organ dose correlation factors developedmore » in phantom were multiplied by 28 chest and 22 abdominopelvic patient SSDE values to estimate organ dose. The median patient weight from the CT examinations was 68.9 kg (range 57–87 kg) and median age was 17 years (range 13–28 years). Calculated organ dose estimates were compared to published Monte Carlo simulated patient and phantom results. Results: Organ-dose-to-SSDE correlation was determined for a total of 23 organs in the chest and abdominopelvic regions. For organs fully covered by the scan volume, correlation in the chest (median 1.3; range 1.1–1.5) and abdominopelvic (median 0.9; range 0.7–1.0) was 1.0 ± 10%. For organs that extended beyond the scan volume (i.e. skin bone marrow and bone surface) correlation was determined to be a median of 0.3 (range 0.1–0.4). Calculated patient organ dose using patient SSDE agreed to better than 6% (chest) and 15% (abdominopelvic) to published values. Conclusion: This study demonstrated that our previous published methodology for calculating organ dose using patient-specific SSDE for the chest and abdominopelvic regions is translatable to adult sized patients for organs fully covered by the scan volume.« less
Han, Yi; Ayalasomayajula, Surya; Pan, Wei; Yang, Fan; Yuan, Yaozong; Langenickel, Thomas; Hinder, Markus; Kalluri, Sampath; Pal, Parasar; Sunkara, Gangadhar
2017-02-01
Sacubitril/valsartan (LCZ696) is a first-in-class angiotensin receptor neprilysin inhibitor (ARNI) and has been recently approved in several countries for the treatment of patients with heart failure and reduced ejection fraction. This was the first study conducted to characterise the pharmacokinetics of LCZ696 analytes (pro-drug sacubitril, active neprilysin inhibitor LBQ657 and valsartan) after single-dose administration of LCZ696 in healthy Chinese subjects. In this open-label, randomised, parallel-group study, following screening and baseline evaluation, eligible healthy subjects received single oral doses of LCZ696 50, 100, 200 or 400 mg. The pharmacokinetics, safety and tolerability of LCZ696 were assessed up to 72 h after dosing. A total of 40 healthy male subjects were enrolled, and all completed the study. Following oral administration, LCZ696 delivered systemic exposure to sacubitril, LBQ657 and valsartan with a median time to reach maximum plasma concentration (T max ) ranging from 0.50 to 1.25, 2.00 to 3.00 and 1.50 to 2.50 h, respectively, over the investigated dose range. The mean terminal elimination half-life (T 1/2 ) ranged from 0.89 to 1.35, 8.57 to 9.24 and 5.33 to 7.91 h for sacubitril, LBQ657 and valsartan, respectively. The area under the plasma concentration-time curve from time zero to the time of the last quantifiable concentration (AUC 0-last ), and maximum plasma concentration (C max ) for LBQ657 increased dose proportionally over the entire dose range. Dose linear increase in the exposure was observed across the dose range for sacubitril and valsartan. LCZ696 was safe and well tolerated at all doses in this study. Adverse events of only mild intensity, which required no treatment, were reported in 6 (15 %) subjects. The pharmacokinetic profiles of LCZ696 analytes in Chinese subjects are similar to those reported previously in Caucasian subjects.
Observation of Kilohertz Quasiperiodic Oscillations from the Atoll Source 4U 1702-429 by RXTE
NASA Technical Reports Server (NTRS)
Markwardt, C. B.; Strohmayer, Tod E.; Swank, Jean H.
1998-01-01
We present results of Rossi X-Ray Timing Explorer (RXTE) observations of the atoll source 4U 1702-429 in the middle of its luminosity range. Kilohertz-range quasiperiodic oscillations (QPOS) were observed first as a narrow (FWHM approximately 7 Hz) peak near 900 Hz, and later as a pair consisting of a narrow peak in the range 625 825 Hz and a faint broad (FWHM 91 Hz) peak. When the two peaks appeared simultaneously the separation was 333 +/- 5 Hz. Six type I thermonuclear bursts were detected, of which five exhibited almost coherent oscillations near 330 Hz, which makes 4U 1702-429 only the second source to show burst oscillations very close to the kilohertz QPO separation frequency. The energy spectrum and color-color diagram indicate that the source executed variations in the range between the "island" and "lower banana" atoll states. In addition to the kilohertz variability, oscillations at approximately 10, approximately 35, and 80 Hz were also detected at various times, superimposed on a red noise continuum. The centroid of the approximately 35 Hz QPO tracks the frequency of the kilohertz oscillation when they were both present. A Lense-Thirring gravitomagnetic precession interpretation appears more plausible in this case, compared to other atoll sources with low frequency QPOs.
Trait correlates of distribution trends in the Odonata of Britain and Ireland
Cham, Steve S.A.; Smallshire, Dave; Isaac, Nick J.B.
2015-01-01
A major challenge in ecology is understanding why certain species persist, while others decline, in response to environmental change. Trait-based comparative analyses are useful in this regard as they can help identify the key drivers of decline, and highlight traits that promote resistance to change. Despite their popularity trait-based comparative analyses tend to focus on explaining variation in range shift and extinction risk, seldom being applied to actual measures of species decline. Furthermore they have tended to be taxonomically restricted to birds, mammals, plants and butterflies. Here we utilise a novel approach to estimate occurrence trends for the Odonata in Britain and Ireland, and examine trait correlates of these trends using a recently available trait dataset. We found the dragonfly fauna in Britain and Ireland has undergone considerable change between 1980 and 2012, with 22 and 53% of species declining and increasing, respectively. Distribution region, habitat specialism and range size were the key traits associated with these trends, where habitat generalists that occupy southern Britain tend to have increased in comparison to the declining narrow-ranged specialist species. In combination with previous evidence, we conclude that the lower trend estimates for the narrow-ranged specialists could be a sign of biotic homogenization with ecological specialists being replaced by warm-adapted generalists. PMID:26618083
Dosimetric properties of a proton beamline dedicated to the treatment of ocular disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slopsema, R. L., E-mail: rslopsema@floridaproton.org; Mamalui, M.; Yeung, D.
2014-01-15
Purpose: A commercial proton eyeline has been developed to treat ocular disease. Radiotherapy of intraocular lesions (e.g., uveal melanoma, age-related macular degeneration) requires sharp dose gradients to avoid critical structures like the macula and optic disc. A high dose rate is needed to limit patient gazing times during delivery of large fractional dose. Dose delivery needs to be accurate and predictable, not in the least because current treatment planning algorithms have limited dose modeling capabilities. The purpose of this paper is to determine the dosimetric properties of a new proton eyeline. These properties are compared to those of existing systemsmore » and evaluated in the context of the specific clinical requirements of ocular treatments. Methods: The eyeline is part of a high-energy, cyclotron-based proton therapy system. The energy at the entrance of the eyeline is 105 MeV. A range modulator (RM) wheel generates the spread-out Bragg peak, while a variable range shifter system adjusts the range and spreads the beam laterally. The range can be adjusted from 0.5 up to 3.4 g/cm{sup 2}; the modulation width can be varied in steps of 0.3 g/cm{sup 2} or less. Maximum field diameter is 2.5 cm. All fields can be delivered with a dose rate of 30 Gy/min or more. The eyeline is calibrated according to the IAEA TRS-398 protocol using a cylindrical ionization chamber. Depth dose distributions and dose/MU are measured with a parallel-plate ionization chamber; lateral profiles with radiochromic film. The dose/MU is modeled as a function of range, modulation width, and instantaneous MU rate with fit parameters determined per option (RM wheel). Results: The distal fall-off of the spread-out Bragg peak is 0.3 g/cm{sup 2}, larger than for most existing systems. The lateral penumbra varies between 0.9 and 1.4 mm, except for fully modulated fields that have a larger penumbra at skin. The source-to-axis distance is found to be 169 cm. The dose/MU shows a strong dependence on range (up to 4%/mm). A linear increase in dose/MU as a function of instantaneous MU rate is observed. The dose/MU model describes the measurements with an accuracy of ±2%. Neutron dose is found to be 146 ± 102 μSv/Gy at the contralateral eye and 19 ± 13 μSv/Gy at the chest. Conclusions: Measurements show the proton eyeline meets the requirements to effectively treat ocular disease.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slopsema, R. L., E-mail: rslopsema@floridaproton.org; Mamalui, M.; Yeung, D.
Purpose: A commercial proton eyeline has been developed to treat ocular disease. Radiotherapy of intraocular lesions (e.g., uveal melanoma, age-related macular degeneration) requires sharp dose gradients to avoid critical structures like the macula and optic disc. A high dose rate is needed to limit patient gazing times during delivery of large fractional dose. Dose delivery needs to be accurate and predictable, not in the least because current treatment planning algorithms have limited dose modeling capabilities. The purpose of this paper is to determine the dosimetric properties of a new proton eyeline. These properties are compared to those of existing systemsmore » and evaluated in the context of the specific clinical requirements of ocular treatments. Methods: The eyeline is part of a high-energy, cyclotron-based proton therapy system. The energy at the entrance of the eyeline is 105 MeV. A range modulator (RM) wheel generates the spread-out Bragg peak, while a variable range shifter system adjusts the range and spreads the beam laterally. The range can be adjusted from 0.5 up to 3.4 g/cm{sup 2}; the modulation width can be varied in steps of 0.3 g/cm{sup 2} or less. Maximum field diameter is 2.5 cm. All fields can be delivered with a dose rate of 30 Gy/min or more. The eyeline is calibrated according to the IAEA TRS-398 protocol using a cylindrical ionization chamber. Depth dose distributions and dose/MU are measured with a parallel-plate ionization chamber; lateral profiles with radiochromic film. The dose/MU is modeled as a function of range, modulation width, and instantaneous MU rate with fit parameters determined per option (RM wheel). Results: The distal fall-off of the spread-out Bragg peak is 0.3 g/cm{sup 2}, larger than for most existing systems. The lateral penumbra varies between 0.9 and 1.4 mm, except for fully modulated fields that have a larger penumbra at skin. The source-to-axis distance is found to be 169 cm. The dose/MU shows a strong dependence on range (up to 4%/mm). A linear increase in dose/MU as a function of instantaneous MU rate is observed. The dose/MU model describes the measurements with an accuracy of ±2%. Neutron dose is found to be 146 ± 102 μSv/Gy at the contralateral eye and 19 ± 13 μSv/Gy at the chest. Conclusions: Measurements show the proton eyeline meets the requirements to effectively treat ocular disease.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deshpande, S; Dhote, D; Kumar, R
Purpose: To measure actual patient eye lens dose for different cone beam computed tomography (CBCT) acquisition protocol of Varian’s On Board Imagining (OBI) system using Optically Stimulated Luminescence (OSL) dosimeter and study the eye lens dose with patient geometry and distance of isocenter to the eye lens Methods: OSL dosimeter was used to measure eye lens dose of patient. OSL dosimeter was placed on patient forehead center during CBCT image acquisition to measure eye lens dose. For three different cone beam acquisition protocol (standard dose head, low dose head and high quality head) of Varian On-Board Imaging, eye lens dosesmore » were measured. Measured doses were correlated with patient geometry and distance between isocenter to eye lens. Results: Measured eye lens dose for standard dose head was in the range of 1.8 mGy to 3.2 mGy, for high quality head protocol dose was in range of 4.5mGy to 9.9 mGy whereas for low dose head was in the range of 0.3mGy to 0.7mGy. Dose to eye lens is depends upon position of isocenter. For posterioraly located tumor eye lens dose is less. Conclusion: From measured doses it can be concluded that by proper selection of imagining protocol and frequency of imaging, it is possible to restrict the eye lens dose below the new limit set by ICRP. However, undoubted advantages of imaging system should be counter balanced by careful consideration of imaging protocol especially for very intense imaging sequences for Adoptive Radiotherapy or IMRT.« less
Real-Time Patient and Staff Radiation Dose Monitoring in IR Practice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sailer, Anna M., E-mail: karmanna@stanford.edu; Paulis, Leonie, E-mail: leonie.paulis@mumc.nl; Vergoossen, Laura
PurposeKnowledge of medical radiation exposure permits application of radiation protection principles. In our center, the first dedicated real-time, automated patient and staff dose monitoring system (DoseWise Portal, Philips Healthcare) was installed. Aim of this study was to obtain insight in the procedural and occupational doses.Materials and MethodsAll interventional radiologists, vascular surgeons, and technicians wore personal dose meters (PDMs, DoseAware, Philips Healthcare). The dose monitoring system simultaneously registered for each procedure dose-related data as the dose area product (DAP) and effective staff dose (E) from PDMs. Use and type of shielding were recorded separately. All procedures were analyzed according to proceduremore » type; these included among others cerebral interventions (n = 112), iliac and/or caval venous recanalization procedures (n = 68), endovascular aortic repair procedures (n = 63), biliary duct interventions (n = 58), and percutaneous gastrostomy procedure (n = 28).ResultsMedian (±IQR) DAP doses ranged from 2.0 (0.8–3.1) (percutaneous gastrostomy) to 84 (53–147) Gy cm{sup 2} (aortic repair procedures). Median (±IQR) first operator doses ranged from 1.6 (1.1–5.0) μSv to 33.4 (12.1–125.0) for these procedures, respectively. The relative exposure, determined as first operator dose normalized to procedural DAP, ranged from 1.9 in biliary interventions to 0.1 μSv/Gy cm{sup 2} in cerebral interventions, indicating large variation in staff dose per unit DAP among the procedure types.ConclusionReal-time dose monitoring was able to identify the types of interventions with either an absolute or relatively high staff dose, and may allow for specific optimization of radiation protection.« less
Port, M; Pieper, B; Dörr, H D; Hübsch, A; Majewski, M; Abend, M
2018-05-01
The degree of severity of hematologic acute radiation syndrome (HARS) may vary across the range of radiation doses, such that dose alone may be a less reliable predictor of clinical course. We sought to elucidate the relationship between absorbed dose and risk of clinically relevant HARS in humans. We used the database SEARCH (System for Evaluation and Archiving of Radiation Accidents based on Case Histories), which contains the histories of radiation accident victims. From 153 cases we extracted data on dose estimates using the dicentric assay to measure individual biological dosimetry. The data were analyzed according to the corresponding hematological response categories of clinical significance (H1-4). These categories are derived from the medical treatment protocols for radiation accident victims (METREPOL) and represent the clinical outcome of HARS based on severity categories ranging from 1-4. In addition, the category H0 represents a post-exposure hematological response that is within the normal range for nonexposed individuals. Age at exposure, gender and ethnicity were considered as potential confounders in unconditional cumulative logistic regression analysis. In most cases, victims were Caucasian (82.4%) and male (92.8%), who originated from either the Chernobyl (69.3%) or Goiânia (10.5%) accident, and nearly 60% were aged 20-40 years at time of exposure. All individuals were whole-body exposed (mean 3.8 Gy, stdev ±3.1), and single exposures were predominantly reported (79%). Seventy percent of victims in category H0 were exposed to ≤1 Gy, with rapidly decreasing proportions of H0 seen at doses up to 5 Gy. There were few HARS H4 cases reported at exposed dose of 1-2 Gy, while 82% of H4 cases received doses of >5 Gy. HARS H1-3 cases varied among dose ranges from 1-5 Gy. In summary, single whole-body radiation doses <1 Gy and >5 Gy corresponded in general with H0 and H3-4, respectively, and this was consistent with medical expectations. This underlines the usefulness of dose estimates for HARS prediction. However, whole-body doses between 1-5 Gy poorly corresponded to HARS H1-3. The dose range of 1-5 Gy was of limited value for medical decision-making regarding, e.g., hospitalization for H2-3, but not H1 and treatment decisions that differ between H1-3. Also, there were some H0 cases at high doses and H2-4 cases at low doses, thereby challenging an individual recommendation based solely on dose.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Chih-Yuan, E-mail: chen6563@gmail.com; Department of Materials Science and Engineering, National Taiwan University, Taipei 10617, Taiwan; Yang, Jer-Ren, E-mail: jryang@ntu.edu.tw
Nanometer-sized carbides that precipitated in a Ti–Mo bearing steel after interrupted continuous cooling in a temperature range of 620–700 °C with or without hot deformation were investigated by field-emission-gun transmission electron microscopy. The nanometer-sized carbides were identified as randomly homogeneous precipitation carbides and interphase precipitation carbides coexisting in the ferrite matrix. It is found that this dual precipitation morphology of carbides in the steel leads to the non-uniform mechanical properties of individual ferrite grains. Vickers hardness data mainly revealed that, in the specimens cooled at a rate of 0.5 °C/s without hot deformation, the range of Vickers hardness distribution wasmore » 230–340 HV 0.1 when cooling was interrupted at 680 °C, and 220–360 HV 0.1 when cooling was interrupted at 650 °C. For the specimens cooled at a rate of 0.5 °C/s with hot deformation, the range of Vickers hardness distribution was 290–360 HV 0.1 when cooling was interrupted at 680 °C, and 280–340 HV 0.1 when cooling was interrupted at 650 °C. Therefore, a narrower range of hardness distribution occurred in the specimens that underwent hot deformation and were then cooled with a lower interrupted cooling temperature. The uniform precipitation status in each ferrite grain can lead to ferrite grains with a narrower Vickers hardness distribution. On the other hand, interrupted cooling produced a maximum Vickers hardness of 320–330 HV 0.1 for the hot deformed specimens and 290–310 HV 0.1 for the non-deformed specimens with cooling interrupted in the temperature range of 660–670 °C. The maximum Vickers hardness obtained in such a temperature range can be ascribed to the full precipitation of the microalloying elements in the supersaturated ferrite matrix with a tiny size (~ 4–7 nm). - Highlight: • The interrupted continuous cooling temperatures were 620 °C to 700 °C. • Precipitation carbides with dual dispersed morphology coexisted in the matrix. • Heavy hot deformation narrowed the range of hardness distribution. • Full precipitation of nano-sized carbides achieved maximum hardening.« less
An end-to-end assessment of range uncertainty in proton therapy using animal tissues.
Zheng, Yuanshui; Kang, Yixiu; Zeidan, Omar; Schreuder, Niek
2016-11-21
Accurate assessment of range uncertainty is critical in proton therapy. However, there is a lack of data and consensus on how to evaluate the appropriate amount of uncertainty. The purpose of this study is to quantify the range uncertainty in various treatment conditions in proton therapy, using transmission measurements through various animal tissues. Animal tissues, including a pig head, beef steak, and lamb leg, were used in this study. For each tissue, an end-to-end test closely imitating patient treatments was performed. This included CT scan simulation, treatment planning, image-guided alignment, and beam delivery. Radio-chromic films were placed at various depths in the distal dose falloff region to measure depth dose. Comparisons between measured and calculated doses were used to evaluate range differences. The dose difference at the distal falloff between measurement and calculation depends on tissue type and treatment conditions. The estimated range difference was up to 5, 6 and 4 mm for the pig head, beef steak, and lamb leg irradiation, respectively. Our study shows that the TPS was able to calculate proton range within about 1.5% plus 1.5 mm. Accurate assessment of range uncertainty in treatment planning would allow better optimization of proton beam treatment, thus fully achieving proton beams' superior dose advantage over conventional photon-based radiation therapy.
SU-F-T-313: Clinical Results of a New Customer Acceptance Test for Elekta VMAT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rusk, B; Fontenot, J
Purpose: To report the results of a customer acceptance test (CAT) for VMAT treatments for two matched Elekta linear accelerators. Methods: The CAT tests were performed on two clinically matched Elekta linear accelerators equipped with a 160-leaf MLC. Functional tests included performance checks of the control system during dynamic movements of the diaphragms, MLC, and gantry. Dosimetric tests included MLC picket fence tests at static and variable dose rates and a diaphragm alignment test, all performed using the on-board EPID. Additionally, beam symmetry during arc delivery was measured at the four cardinal angles for high and low dose rate modesmore » using a 2D detector array. Results of the dosimetric tests were analyzed using the VMAT CAT analysis tool. Results: Linear accelerator 1 (LN1) met all stated CAT tolerances. Linear accelerator 2 (LN2) passed the geometric, beam symmetry, and MLC position error tests but failed the relative dose average test for the diaphragm abutment and all three picket fence fields. Though peak doses in the abutment regions were consistent, the average dose was below the stated tolerance corresponding to a leaf junction that was too narrow. Despite this, no significant differences in patient specific VMAT quality assurance measured were observed between the accelerators and both passed monthly MLC quality assurance performed with the Hancock test. Conclusion: Results from the CAT showed LN2 with relative dose averages in the abutment regions of the diaphragm and MLC tests outside the tolerances resulting from differences in leaf gap distances. Tolerances of the dose average tests from the CAT may be small enough to detect MLC errors which do not significantly affect patient QA or the routine MLC tests.« less
Lundh, O; Rechatin, C; Faure, J; Ben-Ismaïl, A; Lim, J; De Wagter, C; De Neve, W; Malka, V
2012-06-01
To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced. A secondary laser beam is used to optically control and to tune the electron beam energy and charge. The potential use of this beam for radiation treatment is evaluated experimentally by measurements of dose deposition in a polystyrene phantom. The results are compared to Monte Carlo simulations using the geant4 code. It has been shown that the laser-plasma accelerated electron beam can deliver a peak dose of more than 1 Gy at the entrance of the phantom in a single laser shot by direct irradiation, without the use of intermediate magnetic transport or focusing. The dose distribution is peaked on axis, with narrow lateral penumbra. Monte Carlo simulations of electron beam propagation and dose deposition indicate that the propagation of the intense electron beam (with large self-fields) can be described by standard models that exclude collective effects in the response of the material. The measurements show that the high-energy electron beams produced by an optically injected laser-plasma accelerator can deliver high enough dose at penetration depths of interest for electron beam radiotherapy of deep-seated tumors. Many engineering issues must be resolved before laser-accelerated electrons can be used for cancer therapy, but they also represent exciting challenges for future research. © 2012 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Piao, Daqing; Sypniewski, Lara A.; Bartels, Kenneth E.
2017-02-01
Photobiomodulation (PBM) has been used successfully for the treatment of nervous system and has been demonstrated in the rodent model. In contrast, the percutaneous use of PBM to treat spinal cord of companion animals is expected to be challenging due to the significant attenuation of light energy as it travels through the thick and heterogeneous layers of tissue and bone to reach the level of the spinal cord. This pilot study was performed on a cadaverous dog to determine if the recommended bio-stimulatory treatment dose can be delivered to the spinal canal via percutaneous application of a clinically acceptable surface dose. The dose reaching the spinal canal after percutaneous application was measured at 980nm by using a miniature photo-diode sensor with a dose-response sensitivity of 1V per 1mW/cm2 dose and a 2mm spherical isotropic fiber-optical diffusor probe. The two sensors were embedded in different longitudinal positions along the dorsal portion of the spinal canal just below the soft tissues and vertebral processes in a 40lbs cadaverous dog. The spinal cord was then accessed via a hemilaminectomy. Once embedded in the target tissue, 1W-10 W surface irradiation was applied. At the T12/13 and T13/L1 intervertebral disc positions, photo-diode sensors detected the intra-spinal dose above the noise floor at the 10W surface dose. A narrow treatment window for percutaneous PBM in large dog may exist only for the shallowest segment of the spinal cord, which may be important to avoid potential collateral photothermal effects. Works for simultaneous multi-site intra-spinal measurements are on-going.
Cheung, D; Timmers, M C; Zwinderman, A H; den Hartigh, J; Dijkman, J H; Sterk, P J
1993-12-01
In a previous study we have shown that inhibition of the endogenous neuropeptide-degrading enzyme, neutral endopeptidase (NEP), potentiates airway narrowing to neurokinin A (NKA) in normal humans in vivo. In the present study, we tested the hypothesis that hyperresponsiveness to NKA in asthma is caused by a reduction in endogenous NEP activity. To that end, we used the NEP inhibitor, thiorphan, or placebo as inhaled pretreatment to NKA challenge in eight atopic asthmatic men, who were controlled by on-demand usage of beta 2-agonists alone. The dose of thiorphan pretreatment was obtained from pilot experiments in which 0.5 ml of a 2.5-mg/ml concentration appeared to be the maximally effective nebulized dose. Dose-response curves to inhaled NKA (1 to 125 micrograms/ml, 0.5 ml/dose) were recorded on 2 randomized days 1 wk apart, in a cross-over study. To detect any effects of thiorphan on bronchoconstriction per se, we also investigated the effect of thiorphan or placebo on the dose-response curve to inhaled methacholine in a separate set of experiments. The response was measured by FEV1 and by partial expiratory flow-volume curves (V40p). The position of the dose-response curves was expressed as the concentration causing a 20% fall in FEV1 (PC20FEV1) or a 40% fall in V40p (PC40V40p). Baseline FEV1 and V40p were not affected by either pretreatment (p > 0.06). PC20FEV1 and PC40V40p to NKA were significantly lower after thiorphan pretreatment as compared with placebo (mean difference +/- SEM: 2.3 +/- 0.6 and 1.6 +/- 0.5 doubling dose, respectively; p < 0.015).(ABSTRACT TRUNCATED AT 250 WORDS)
NASA Astrophysics Data System (ADS)
Cunningham, E.; Cribb, J. W.
2017-12-01
The northern Oregon Cascade Range has been dominated by andesite to rhyodacite lavas at both Mt. Jefferson (Conrey, 1991) and at Mt. Hood (Cribb and Barton, 1996) during the Quaternary period. Eruptive sequences at both Mt. Hood and Mt. Jefferson have been attributed to open-system mama mixing (Kent et al., 2010) (Ferrell et al., 2015), and the narrow range of lavas erupted at both centers has been derived from repeated cycles of magma mixing-fractionation (Cribb and Barton, 1996). This research examines major and trace element geochemistry as well as the petrographic characteristics of Clear Lake Butte (CLB), Pinhead Butte (PB), and Olallie Butte (OB), all of which are located between Mt. Hood and Mt. Jefferson, and have ben active in the Quaternary period. The research investigates whether the same type of open-system magma mixing known to have occurred at Mt. Hood and Mt. Jefferson has also occurred at CLB, PB, or OB, or whether those systems were closed to mixing and dominated by fractional crystallization. One of the main goals of this project is to highlight the similarities and differences exhibited by neighboring magmatic systems of similar age, but different scale. Disequilibrium textures observed in thin sections from CLB, OB, and PB suggest open-system magma mixing is likely occurring beneath all three buttes. This petrographic evidence includes plagioclase and pyroxene zoning, embayed margins, sieving, and reaction rims. Major element oxide trends at all three buttes are consistent with fractional crystallization, but show narrow concentrations and non-overlapping compositions between PB, CLB, and OB. All three buttes are characterized by narrow ranges of incompatible and compatible trace element concentrations. CLB, PB, and OB all exhibit LREE enrichment and lack significant HFSE depletions, with PB exhibiting greatest enrichment in REE.
Photodiode Preamplifier for Laser Ranging With Weak Signals
NASA Technical Reports Server (NTRS)
Abramovici, Alexander; Chapsky, Jacob
2007-01-01
An improved preamplifier circuit has been designed for processing the output of an avalanche photodiode (APD) that is used in a high-resolution laser ranging system to detect laser pulses returning from a target. The improved circuit stands in contrast to prior such circuits in which the APD output current pulses are made to pass, variously, through wide-band or narrow-band load networks before preamplification. A major disadvantage of the prior wide-band load networks is that they are highly susceptible to noise, which degrades timing resolution. A major disadvantage of the prior narrow-band load networks is that they make it difficult to sample the amplitudes of the narrow laser pulses ordinarily used in ranging. In the improved circuit, a load resistor is connected to the APD output and its value is chosen so that the time constant defined by this resistance and the APD capacitance is large, relative to the duration of a laser pulse. The APD capacitance becomes initially charged by the pulse of current generated by a return laser pulse, so that the rise time of the load-network output is comparable to the duration of the return pulse. Thus, the load-network output is characterized by a fast-rising leading edge, which is necessary for accurate pulse timing. On the other hand, the resistance-capacitance combination constitutes a lowpass filter, which helps to suppress noise. The long time constant causes the load network output pulse to have a long shallow-sloping trailing edge, which makes it easy to sample the amplitude of the return pulse. The output of the load network is fed to a low-noise, wide-band amplifier. The amplifier must be a wide-band one in order to preserve the sharp pulse rise for timing. The suppression of noise and the use of a low-noise amplifier enable the ranging system to detect relatively weak return pulses.
Monolithically integrated mid-infrared sensor using narrow mode operation and temperature feedback
NASA Astrophysics Data System (ADS)
Ristanic, Daniela; Schwarz, Benedikt; Reininger, Peter; Detz, Hermann; Zederbauer, Tobias; Andrews, Aaron Maxwell; Schrenk, Werner; Strasser, Gottfried
2015-01-01
A method to improve the sensitivity and selectivity of a monolithically integrated mid-infrared sensor using a distributed feedback laser (DFB) is presented in this paper. The sensor is based on a quantum cascade laser/detector system built from the same epitaxial structure and with the same fabrication approach. The devices are connected via a dielectric-loaded surface plasmon polariton waveguide with a twofold function: it provides high light coupling efficiency and a strong interaction of the light with the environment (e.g., a surrounding fluid). The weakly coupled DFB quantum cascade laser emits narrow mode light with a FWHM of 2 cm-1 at 1586 cm-1. The room temperature laser threshold current density is 3 kA/cm2 and a pulsed output power of around 200 mW was measured. With the superior laser noise performance, due to narrow mode emission and the compensation of thermal fluctuations, the lower limit of detection was expanded by one order of magnitude to the 10 ppm range.
[Study on the Spectral Characteristics of the Narrow-Band Filter in SHS].
Luo, Hai-yan; Shi, Hai-liang; Li, Zhi-wei; Li, Shuang; Xiong, Wei; Hong, Jin
2015-04-01
The spectral response of spatial heterodyne spectroscopy (SHS) is determined by the spectrum property of narrow-band filter. As discussed in previous studies, the symmetric heterodyned interferogram of high frequency waves modulated by SHS and lack of sample lead to spectral confusion, which is associated with the true and ghost spectra. Because of the deviation from theoretical index of narrow-band filter in the process of coating, the boarded spectral response and middle wave shift are presented, and conditions in the theoretical Littrow wavelength made the effective wavelength range of SHS reduced. According to the measured curve of filter, a new wavenumber of zero spatial frequency can be reset by tunable laser, and it is easy for SHS to improve the spectral aliasing distortion. The results show that it is utilized to the maximum extent of the effective bandwidth by adjusting the grating angle of rotation to change the Littrow wavelength of the basic frequency, and the spectral region increased to 14.9 nm from original 12.9 nm.
A filterless, visible-blind, narrow-band, and near-infrared photodetector with a gain
NASA Astrophysics Data System (ADS)
Shen, Liang; Zhang, Yang; Bai, Yang; Zheng, Xiaopeng; Wang, Qi; Huang, Jinsong
2016-06-01
In many applications of near-infrared (NIR) light detection, a band-pass filter is needed to exclude the noise caused by visible light. Here, we demonstrate a filterless, visible-blind, narrow-band NIR photodetector with a full-width at half-maximum of <50 nm for the response spectrum. These devices have a thick (>4 μm) nanocomposite absorbing layers made of polymer-fullerene:lead sulfide (PbS) quantum dots (QDs). The PbS QDs yield a photoconductive gain due to their hole-trapping effect, which effectively enhances both the responsivity and the visible rejection ratio of the external quantum efficiency by >10 fold compared to those without PbS QDs. Encouragingly, the inclusion of the PbS QDs does not increase the device noise. We directly measured a noise equivalent power (NEP) of 6.1 pW cm-2 at 890 nm, and a large linear dynamic range (LDR) over 11 orders of magnitude. The highly sensitive visible-blind NIR narrow-band photodetectors may find applications in biomedical engineering.
Ultranarrow-bandwidth filter based on a thermal EIT medium.
Wang, Gang; Wang, Yu-Sheng; Huang, Emily Kay; Hung, Weilun; Chao, Kai-Lin; Wu, Ping-Yeh; Chen, Yi-Hsin; Yu, Ite A
2018-05-21
We present high-contrast electromagnetically-induced-transparency (EIT) spectra in a heated vapor cell of single isotope 87 Rb atoms. The EIT spectrum has both high resonant transmission up to 67% and narrow linewidth of 1.1 MHz. We get rid of the possible amplification resulted from the effects of amplification without population inversion and four-wave mixing. Therefore, this high transmitted light is not artificial. The theoretical prediction of the probe transmission agrees well with the data and the experimental parameters can be derived reasonably from the model. Such narrow and high-contrast spectral profile can be employed as a high precision bandpass filter, which provides a significant advantage in terms of stability and tunability. The central frequency tuning range of the filter is larger than 100 MHz with out-of-band blocking ≥15 dB. This bandpass filter can effectively produce light fields with subnatural linewidth. Nonlinearity associating with the narrow-linewidth and high-contrast EIT profile can be very useful in the applications utilizing the EIT effect.
High power narrow-band fiber-based ASE source.
Schmidt, O; Rekas, M; Wirth, C; Rothhardt, J; Rhein, S; Kliner, A; Strecker, M; Schreiber, T; Limpert, J; Eberhardt, R; Tünnermann, A
2011-02-28
In this paper we describe a high power narrow-band amplified spontaneous emission (ASE) light source at 1030 nm center wavelength generated in an Yb-doped fiber-based experimental setup. By cutting a small region out of a broadband ASE spectrum using two fiber Bragg gratings a strongly constrained bandwidth of 12±2 pm (3.5±0.6 GHz) is formed. A two-stage high power fiber amplifier system is used to boost the output power up to 697 W with a measured beam quality of M2≤1.34. In an additional experiment we demonstrate a stimulated Brillouin scattering (SBS) suppression of at least 17 dB (theoretically predicted ~20 dB), which is only limited by the dynamic range of the measurement and not by the onset of SBS when using the described light source. The presented narrow-band ASE source could be of great interest for brightness scaling applications by beam combination, where SBS is known as a limiting factor.
Cieri, Domenico; Vicario, Mattia; Giacomello, Marta; Vallese, Francesca; Filadi, Riccardo; Wagner, Tina; Pozzan, Tullio; Pizzo, Paola; Scorrano, Luca; Brini, Marisa; Calì, Tito
2018-06-01
Contact sites are discrete areas of organelle proximity that coordinate essential physiological processes across membranes, including Ca 2+ signaling, lipid biosynthesis, apoptosis, and autophagy. However, tools to easily image inter-organelle proximity over a range of distances in living cells and in vivo are lacking. Here we report a split-GFP-based contact site sensor (SPLICS) engineered to fluoresce when organelles are in proximity. Two SPLICS versions efficiently measured narrow (8-10 nm) and wide (40-50 nm) juxtapositions between endoplasmic reticulum and mitochondria, documenting the existence of at least two types of contact sites in human cells. Narrow and wide ER-mitochondria contact sites responded differently to starvation, ER stress, mitochondrial shape modifications, and changes in the levels of modulators of ER-mitochondria juxtaposition. SPLICS detected contact sites in soma and axons of D. rerio Rohon Beard (RB) sensory neurons in vivo, extending its use to analyses of organelle juxtaposition in the whole animal.
Narrow-band radio flares from red dwarf stars
NASA Technical Reports Server (NTRS)
White, Stephen M.; Kundu, Mukul R.; Jackson, Peter D.
1986-01-01
VLA observations of narrow-band behavior in 20 cm flares from two red dwarf stars, L726 - 8A and AD Leo, are reported. The flare on L726 - 8A was observed at 1415 and 1515 MHz; the flux and the evolution differed significantly at the two frequencies. The flare on AD Leo lasted for 2 hr at 1415 MHz but did not appear at 1515 MHz. The AD Leo flare appears to rule out a source drifting through the stellar corona and is unlikely to be due to plasma emission. In the cyclotron maser model the narrow-band behavior reflects the range of magnetic fields present within the source. The apparent constancy of this field for 2 hr is difficult to understand if magnetic reconnection is the source of energy for the flare. The consistent polarization exhibited by red dwarf flares at 20 cm may be related to stellar activity cycles, and changes in this polarization will permit measuring the length of these cycles.
Methods for Probabilistic Radiological Dose Assessment at a High-Level Radioactive Waste Repository.
NASA Astrophysics Data System (ADS)
Maheras, Steven James
Methods were developed to assess and evaluate the uncertainty in offsite and onsite radiological dose at a high-level radioactive waste repository to show reasonable assurance that compliance with applicable regulatory requirements will be achieved. Uncertainty in offsite dose was assessed by employing a stochastic precode in conjunction with Monte Carlo simulation using an offsite radiological dose assessment code. Uncertainty in onsite dose was assessed by employing a discrete-event simulation model of repository operations in conjunction with an occupational radiological dose assessment model. Complementary cumulative distribution functions of offsite and onsite dose were used to illustrate reasonable assurance. Offsite dose analyses were performed for iodine -129, cesium-137, strontium-90, and plutonium-239. Complementary cumulative distribution functions of offsite dose were constructed; offsite dose was lognormally distributed with a two order of magnitude range. However, plutonium-239 results were not lognormally distributed and exhibited less than one order of magnitude range. Onsite dose analyses were performed for the preliminary inspection, receiving and handling, and the underground areas of the repository. Complementary cumulative distribution functions of onsite dose were constructed and exhibited less than one order of magnitude range. A preliminary sensitivity analysis of the receiving and handling areas was conducted using a regression metamodel. Sensitivity coefficients and partial correlation coefficients were used as measures of sensitivity. Model output was most sensitive to parameters related to cask handling operations. Model output showed little sensitivity to parameters related to cask inspections.
Philosophe, Benjamin; Leca, Nicolae; West-Thielke, Patricia M; Horwedel, Timothy; Culkin-Gemmell, Christine; Kistler, Kristin; Stevens, Daniel R
2018-02-20
The majority of United States kidney transplant patients are treated with tacrolimus, a drug effective in preventing graft rejection, but with a narrow therapeutic range, necessitating close monitoring to avoid increased risks of transplant rejection or toxicity if the tacrolimus concentration is too low or too high, respectively. The trough drug concentration tests are time sensitive; patients treated on a twice-daily basis have blood draws exactly 12 hours after their previous dose. The schedule's rigidity causes problems for both patients and health care providers. Novel once-daily tacrolimus formulations such as LCPT (an extended-release tablet by Veloxis Pharmaceuticals, Inc., Cary, North Carolina) have allowed for blood draws on a once-daily basis; however, even that schedule can be restrictive. Results from tests taken either before or after that 24-hour target time may be discarded, or worse, may lead to inappropriate dose changes. Data from ASTCOFF, a phase 3B pharmacokinetic clinical trial (NCT02339246), demonstrated that the unique pharmacokinetic curve of LCPT may allow for a therapeutic monitoring window that extends for 3 hours before or after the 24-hour monitoring target. Furthermore, important tools to help clinicians interpret these levels, such as formulas to estimate the 24-hour trough level if an alternative monitoring time is used, were constructed from these data. These study results give treating clinicians access to data that allow them to safely use and monitor LCPT in their patients and expand the body of evidence surrounding differentiation and practical application of the novel LCPT tacrolimus formulation. © 2018, The Authors. The Journal of Clinical Pharmacology published by Wiley Periodicals, Inc. on behalf of American College of Clinical Pharmacology.
Microtomographic studies of subdivision of modified-release tablets.
Wilczyński, Sławomir; Koprowski, Robert; Duda, Piotr; Banyś, Anna; Błońska-Fajfrowska, Barbara
2016-09-25
The uniformity of dosage units within a certain batch is ensured when each unit contains the active pharmaceutical ingredient (API) within a narrow range around the label claim. For tablets containing a score-line authorised for dose reductions, the European Pharmacopoeia (Ph. Eur.) considers that the uniformity of the tablet parts may be based on weight measurements regardless of the tablet type (immediate or modified release). This is because it is up to the regulatory authorities first to assess whether the tablet may contain a score-line for such use. X-ray microtomography was applied to assess the symmetry of 36 modified release tablets, containing 300mg of theophylline. The sum of the volume and surface area of the pellets in the subdivided tablets were compared. Simulations were carried out to identify the optimal amount of pellets in the tablet mass. The maximum difference in the API content between two subdivided halves was 165.18mg vs 133.83mg. If the amount of pellets in the tablet mass would drop below 13% on the basis of the pellet surface area, then the Ph. Eur. requirements would be exceeded. The amount of pellets in the tablet halves resulting in the greatest variability in API content was 38%. The results of this study indicate that the pellets were not distributed uniformly in the tablet mass. Thus, the uniformity of the dose in both halves of a tablet containing pellets cannot be based on the weight measurements i.e. it is necessary to develop further standards for tablet subdivision. Microtomographic methods are a very interesting alternative to expensive and time-consuming pharmacokinetic studies. Copyright © 2016 Elsevier B.V. All rights reserved.
Tan, Judith Zhi-Yie; Crossett, Marcus; Ditchfield, Michael
2013-04-01
The aim of this study was to evaluate the dynamic volumetric CT in the assessment of the paediatric airway. Ethics board approval was obtained for this retrospective review. Eight infants (median age 6 months, range 3 weeks to 1 year, 50% female) at a tertiary paediatric centre with complex clinical respiratory presentation underwent volumetric CT assessment of their airways. The entire lungs were examined over 1-2 respiratory cycles. In four patients, intravenous contrast was administered to assess for vascular airway compression. The patients were not intubated. CT findings were correlated with bronchography and bronchoscopy, where available. Two patients had diffuse tracheobronchomalacia associated with chronic lung disease. One patient demonstrated focal severe cervical tracheomalacia. One patient had a double aortic arch causing fixed narrowing with superimposed malacia of the distal trachea. Four patients had normal airways; one with chronic lung disease, one demonstrating air trapping. CT findings were concordant with bronchography (one case) and bronchoscopy (four cases) in all but one (CT negative, bronchoscopy positive) but did not alter patient management. The assessment of the paediatric airway, and in particular for tracheobronchomalacia, is difficult. Assessment with bronchography, bronchoscopy, helical CT and MR have issues with reliability, intubation, intratracheal/bronchial contrast administration and ionising radiation. Volumetric CT assesses the entire central airway in children at much lower radiation dose compared with previous dynamic CT imaging. This non-invasive, rapid assessment obviates the need for patient cooperation and enables evaluation of extratracheal intrathoracic structures. Volumetric CT enables four-dimensional assessment for paediatric tracheobronchomalacia without intubation or patient cooperation and at low radiation dose. © 2012 The Authors. Journal of Medical Imaging and Radiation Oncology © 2012 The Royal Australian and New Zealand College of Radiologists.
A novel filter bank for biotelemetry.
Karagözoglu, B
2001-03-01
In a multichannel biotelemetry system, signals taken from a patient are distributed along the available frequency range (bandwidth) of the system through frequency-division-multiplexing, and combined into a single composite signal. Biological signals that are limited to low frequencies (below 10 Hz) modulate the frequencies of respective sub-carriers. Other biological signals are carried in amplitude-modulated forms. It is recognized that recovering original signals from a composite signal at the receiver side is a technical challenge when a telemetry system with narrow bandwidth capacity is used, since such a system leaves little frequency spacing between information channels. A filter bank is therefore utilized for recovering biological signals that are transmitted. The filter bank contains filter units comprising switched-capacitor filter integrated circuits. The filters have two distinct and opposing outputs (band-stop (notch) and band-pass). Since most biological signals are at low frequencies, and modulated signals occupy a narrow band around the carrier, notch filters can be used to efficiently stop signals in the narrow frequency range. Once the interim channels are removed, other channels become well separated from each other, and band-pass filters can select them. In the proposed system, efficient filtering of closely packed channels is achieved, with low interference, from neighboring channels. The filter bank is applied to a system that carries four biological signals and a battery status indicator signal. Experimental results reinforce theoretical predictions that the filter bank successfully de-multiplexes closely packed information channels with low crosstalk between them. It is concluded that the proposed filter bank allows utilization of cost-effective multichannel biotelemetry systems that are designed around commercial audio devices, and that it can be readily adapted to a broad range of physiological recording requirements.
Ruff, Christian T; Giugliano, Robert P; Braunwald, Eugene; Morrow, David A; Murphy, Sabina A; Kuder, Julia F; Deenadayalu, Naveen; Jarolim, Petr; Betcher, Joshua; Shi, Minggao; Brown, Karen; Patel, Indravadan; Mercuri, Michele; Antman, Elliott M
2015-06-06
New oral anticoagulants for stroke prevention in atrial fibrillation were developed to be given in fixed doses without the need for the routine monitoring that has hindered usage and acceptance of vitamin K antagonists. A concern has emerged, however, that measurement of drug concentration or anticoagulant activity might be needed to prevent excess drug concentrations, which significantly increase bleeding risk. In the ENGAGE AF-TIMI 48 trial, higher-dose and lower-dose edoxaban were compared with warfarin in patients with atrial fibrillation. Each regimen incorporated a 50% dose reduction in patients with clinical features known to increase edoxaban drug exposure. We aim to assess whether adjustment of edoxaban dose in this trial prevented excess drug concentration and the risk of bleeding events. We analysed data from the randomised, double-blind ENGAGE AF-TIMI 48 trial. We correlated edoxaban dose, plasma concentration, and anti-Factor Xa (FXa) activity and compared efficacy and safety outcomes with warfarin stratified by dose reduction status. Patients with atrial fibrillation and at moderate to high risk of stroke were randomly assigned in a 1:1:1 ratio to receive warfarin, dose adjusted to an international normalised ratio of 2·0-3·0, higher-dose edoxaban (60 mg once daily), or lower-dose edoxaban (30 mg once daily). Randomisation was done with use of a central, 24 h, interactive, computerised response system. International normalised ratio was measured using an encrypted point-of-care device. To maintain masking, sham international normalised ratio values were generated for patients assigned to edoxaban. Edoxaban (or placebo-edoxaban in warfarin group) doses were halved at randomisation or during the trial if patients had creatinine clearance 30-50 mL/min, bodyweight 60 kg or less, or concomitant medication with potent P-glycoprotein interaction. Efficacy outcomes included the primary endpoint of all-cause stroke or systemic embolism, ischaemic stroke, and all-cause mortality. Safety outcomes included the primary safety endpoint of major bleeding, fatal bleeding, intracranial haemorrhage, and gastrointestinal bleeding. This trial is registered with ClinicalTrials.gov, number NCT00781391. Between Nov 19, 2008 and Nov 22, 2010, 21 105 patients were recruited. Patients who met clinical criteria for dose reduction at randomisation (n=5356) had higher rates of stroke, bleeding, and death compared with those who did not have a dose reduction (n=15 749). Edoxaban dose ranged from 15 mg to 60 mg, resulting in a two-fold to three fold gradient of mean trough drug exposure (16·0-48·5 ng/mL in 6780 patients with data available) and mean trough anti-FXa activity (0·35-0·85 IU/mL in 2865 patients). Dose reduction decreased mean exposure by 29% (from 48·5 ng/mL [SD 45·8] to 34·6 ng/mL [30·9]) and 35% (from 24·5 ng/mL [22·7] to 16·0 ng/mL [14·5]) and mean anti-FXa activity by 25% (from 0·85 IU/mL [0·76] to 0·64 IU/mL [0·54]) and 20% (from 0·44 IU/mL [0·37] to 0·35 IU/mL [0·28]) in the higher-dose and lower-dose regimens, respectively. Despite the lower anti-FXa activity, dose reduction preserved the efficacy of edoxaban compared with warfarin (stroke or systemic embolic event: higher dose pinteraction=0·85, lower dose pinteraction=0·99) and provided even greater safety (major bleeding: higher dose pinteraction 0·02, lower dose pinteraction=0·002). These findings validate the strategy that tailoring of the dose of edoxaban on the basis of clinical factors alone achieves the dual goal of preventing excess drug concentrations and helps to optimise an individual patient's risk of ischaemic and bleeding events and show that the therapeutic window for edoxaban is narrower for major bleeding than thromboembolism. Daiichi-Sankyo Pharma Development. Copyright © 2015 Elsevier Ltd. All rights reserved.
Current national initiatives about drug policies and cost control in Europe: the Italy example.
Rocchi, Francesca; Addis, Antonio; Martini, Nello
2004-01-01
Pharmaceutical expenditure is a challenge to the financial compatibility of health systems because it is growing faster (+11% per year in the last 5 years in Italy) than any other health sector. In order to curb public pharmaceutical expenditure 2 interventions are commonly used: delisting (de-reimbursement) and reference price, with the difference being paid by patients. The Italian Ministry of Health implemented a set of interventions with the general aim of pharmaceutical governance based on the following criteria: (a) to assure a complete coverage of all clinically and epidemiologically relevant diseases; (b) to provide health professionals with a range of different active drugs with the same therapeutic indications within the same therapeutic class; and (c) to identify a reimbursement threshold in order to save public money by narrowing the (wide) price differentials among drugs with comparable efficacy and safety. In this context, interventions have been undertaken at several levels including drug price reduction, generic drug promotion, delisting of drugs reimbursed, and direct distribution of medicines (by hospital services). Furthermore, a new National Pharmaceutical Formulary has been implemented. Medicines have been classified into homogeneous categories (ie, medicines with the same main indication(s) and with similar clinical efficacy and safety profile). Within each homogeneous category, a reimbursement level (cutoff) was then identified and, accordingly, pharmaceutical companies were asked to adjust their price. This adjustment was based on price per daily drug dose (DDD), cumulative expenditure (at least 50%), and cumulative utilization (at least 60%). This readjustment, at no cost for patients, is expected to save more than Euro 280 million of public money. Seventy-seven percent of this saving will be due to price readjustment of antiulcers, calcium channel blockers, angiotensin-converting enzyme (ACE) inhibitors, and some antibiotics (mainly cephalosporins). The Italian system was able to cover all relevant diseases and ensured citizens and health professionals a choice among a wide range of valid pharmacological therapies. At the same time it was able to save public money by narrowing wide price differentials among drugs with comparable clinical properties. The set of interventions yielded a new national formulary that was able to have a significant influence on the trend of drug expenditure in Italy. This experience can be a useful reference for other European and non-European states.
SU-F-J-197: A Novel Intra-Beam Range Detection and Adaptation Strategy for Particle Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, M; Jiang, S; Shao, Y
2016-06-15
Purpose: In-vivo range detection/verification is crucial in particle therapy for effective and safe delivery. The state-of-art techniques are not sufficient for in-vivo on-line range verification due to conflicts among patient dose, signal statistics and imaging time. We propose a novel intra-beam range detection and adaptation strategy for particle therapy. Methods: This strategy uses the planned mid-range spots as probing beams without adding extra radiation to patients. Such choice of probing beams ensures the Bragg peaks to remain inside the tumor even with significant range variation from the plan. It offers sufficient signal statistics for in-beam positron emission tomography (PET) duemore » to high positron activity of therapeutic dose. The probing beam signal can be acquired and reconstructed using in-beam PET that allows for delineation of the Bragg peaks and detection of range shift with ease of detection enabled by single-layered spots. If the detected range shift is within a pre-defined tolerance, the remaining spots will be delivered as the original plan. Otherwise, a fast re-optimization using range-shifted beamlets and accounting for the probing beam dose is applied to consider the tradeoffs posed by the online anatomy. Simulated planning and delivery studies were used to demonstrate the effectiveness of the proposed techniques. Results: Simulations with online range variations due to shifts of various foreign objects into the beam path showed successful delineation of the Bragg peaks as a result of delivering probing beams. Without on-line delivery adaptation, dose distribution was significantly distorted. In contrast, delivery adaptation incorporating detected range shift recovered well the planned dose. Conclusion: The proposed intra-beam range detection and adaptation utilizing the planned mid-range spots as probing beams, which illuminate the beam range with strong and accurate PET signals, is a safe, practical, yet effective approach to address range uncertainty issues in particle therapy.« less
McCune, Jeannine S.; Baker, K. Scott; Blough, David K.; Gamis, Alan; Bemer, Meagan J.; Kelton-Rehkopf, Megan C.; Winter, Laura; Barrett, Jeffrey S.
2016-01-01
Personalizing intravenous (IV) busulfan doses in children using therapeutic drug monitoring (TDM) is an integral component of hematopoietic cell transplant. The authors sought to characterize initial dosing and TDM of IV busulfan, along with factors associated with busulfan clearance, in 729 children who underwent busulfan TDM from December 2005 to December 2008. The initial IV busulfan dose in children weighing ≤12 kg ranged 4.8-fold, with only 19% prescribed the package insert dose of 1.1 mg/kg. In those children weighing >12 kg, the initial dose ranged 5.4-fold, and 79% were prescribed the package insert dose. The initial busulfan dose achieved the target exposure in only 24.3% of children. A wide range of busulfan exposures were targeted for children with the same disease (eg, 39 target busulfan exposures for the 264 children diagnosed with acute myeloid leukemia). Considerable heterogeneity exists regarding when TDM is conducted and the number of pharmacokinetic samples obtained. Busulfan clearance varied by age and dosing frequency but not by underlying disease. The authors’ group is currently evaluating how using population pharmacokinetics to optimize initial busulfan dose and TDM (eg, limited sampling schedule in conjunction with maximum a posteriori Bayesian estimation) may affect clinical outcomes in children. PMID:23444282
Dose Response Data for Hormonally Active Chemicals ...
The shape of the dose response curve in the low dose region has been debated since the late 1940s. The debate originally focused on linear no threshold (LNT) vs threshold responses in the low dose range for cancer and noncancer related effects. For noncancer effects the default assumption is that noncancer effects generally display threshold rather than LNT responses. More recently, claims have arisen that the chemicals, like endocrine disrupters (EDS), which act via high affinity, low capacity nuclear receptors, may display LNT or nonmonotonic low dose responses: responses that could be missed in multigenerational guideline toxicity testing. This presentation will discuss LNT, threshold and nonmonotonic dose response relationships from case studies of chemicals that disrupt reproductive development and function via the ER, AR and AhR pathways and will include in vitro and in vivo multigenerational data. The in vivo studies in this discussion include only robust, well designed, comprehensive studies that administered the chemical via a relevant route(s) of exposure over a broad dose response range, including low dose(s) in the microgram/kg/d range. The chemicals include ethinyl estradiol, estradiol, genistein, bisphenol a, trenbolone, finasteride, flutamide, phthalate esters and 2,3,7,8 TCDD. The objective is to critically evaluate the data from well done studies in this field to address concerns that current multigenerational reproductive test gui
Browning, David J; Lee, Chong; Rotberg, David
2014-01-01
To determine how algorithms for ideal body weight (IBW) affect hydroxychloroquine dosing in women. This was a retrospective study of 520 patients screened for hydroxychloroquine retinopathy. Charts were reviewed for sex, height, weight, and daily dose. The outcome measures were ranges of IBW across algorithms; rates of potentially toxic dosing; height thresholds below which 400 mg/d dosing is potentially toxic; and rates for which actual body weight (ABW) was less than IBW. Women made up 474 (91%) of the patients. The IBWs for a height varied from 30-34 pounds (13.6-15.5 kg) across algorithms. The threshold heights below which toxic dosing occurred varied from 62-70 inches (157.5-177.8 cm). Different algorithms placed 16%-98% of women in the toxic dosing range. The proportion for whom dosing should have been based on ABW rather than IBW ranged from 5%-31% across algorithms. Although hydroxychloroquine dosing should be based on the lesser of ABW and IBW, there is no consensus about the definition of IBW. The Michaelides algorithm is associated with the most frequent need to adjust dosing; the Metropolitan Life Insurance, large frame, mean value table with the least frequent need. No evidence indicates that one algorithm is superior to others.
NASA Astrophysics Data System (ADS)
Denis-Bacelar, Ana M.; Chittenden, Sarah J.; Murray, Iain; Divoli, Antigoni; McCready, V. Ralph; Dearnaley, David P.; O'Sullivan, Joe M.; Johnson, Bernadette; Flux, Glenn D.
2017-04-01
Skeletal tumour burden is a biomarker of prognosis and survival in cancer patients. This study proposes a novel method based on the linear quadratic model to predict the reduction in metastatic tumour burden as a function of the absorbed doses delivered from molecular radiotherapy treatments. The range of absorbed doses necessary to eradicate all the bone lesions and to reduce the metastatic burden was investigated in a cohort of 22 patients with bone metastases from castration-resistant prostate cancer. A metastatic burden reduction curve was generated for each patient, which predicts the reduction in metastatic burden as a function of the patient mean absorbed dose, defined as the mean of all the lesion absorbed doses in any given patient. In the patient cohort studied, the median of the patient mean absorbed dose predicted to reduce the metastatic burden by 50% was 89 Gy (interquartile range: 83-105 Gy), whilst a median of 183 Gy (interquartile range: 107-247 Gy) was found necessary to eradicate all metastases in a given patient. The absorbed dose required to eradicate all the lesions was strongly correlated with the variability of the absorbed doses delivered to multiple lesions in a given patient (r = 0.98, P < 0.0001). The metastatic burden reduction curves showed a potential large reduction in metastatic burden for a small increase in absorbed dose in 91% of patients. The results indicate the range of absorbed doses required to potentially obtain a significant survival benefit. The metastatic burden reduction method provides a simple tool that could be used in routine clinical practice for patient selection and to indicate the required administered activity to achieve a predicted patient mean absorbed dose and reduction in metastatic tumour burden.
Food irradiation dosimetry by opti-chromic technique
NASA Astrophysics Data System (ADS)
Zhan-Jun, Liu; Radak, B. B.; McLaughlin, W. L.
The measurement of gamma-radiation quantities, e.g., absorbed dose in materials such as water, plastics, foodstuffs, is a convenient means of quality assurance in radiation processing. A new dosimetry system, called the "Opti-Chromic" dosimeter, is commercially available in large batches for use as a routine measurement system in the absorbed dose range 10 to 2x10 4 Gy. This dose range covers most food irradiation applications. A statistical evaluation was made of the reproducibility of this dosimeter for measuring doses appropriate for the disinfestation and shelf-life extension of many foods, namely 10 to 2x10 3 Gy. In addition, the small dosimeters were used to map absorbed dose distributions in boxes of foods having four different bulk densities (grapefruit, lemons, peanuts, and wheat bran). It is demonstrated that the dosimeters are rugged and stable enough to be used over a wide temperature and humidity range, and, in fact, can be placed in such environments as the inside of citrus fruits without adverse effects on their ability to give satisfactory dose assessment.
Hard, Marjie L; Mills, Richard J; Sadler, Brian M; Turncliff, Ryan Z; Citrome, Leslie
2017-06-01
Aripiprazole lauroxil is an extended-release prodrug of aripiprazole for intramuscular injection, approved for schizophrenia treatment. We developed a population pharmacokinetic (PopPK) model to characterize aripiprazole lauroxil PK and evaluate dosing scenarios likely to be encountered in clinical practice. Data from 616 patients with schizophrenia, collected from 5 clinical studies, were used to construct the PopPK model. The model was subsequently used to evaluate various dose levels and frequency and the impact of dosing delay on aripiprazole concentrations. The results of the model indicate that aripiprazole is released into the systemic circulation after 5 to 6 days, and release continues for an additional 36 days. The slow increase in aripiprazole concentration after injection necessitates the coadministration of oral aripiprazole for 21 days with the first injection. Based on the PopPK model simulations, a dosing interval of 882 mg every 6 weeks results in aripiprazole concentrations that fall within the concentration range associated with the efficacious aripiprazole lauroxil dose range (441-882 mg dosed monthly). A 662-mg monthly dose also resulted in aripiprazole concentrations within the efficacious dose range. Aripiprazole lauroxil administration results in prolonged exposure, such that dose delays of 2 to 4 weeks, depending on the dose regimen, do not require oral aripiprazole supplementation upon resumption of dosing. This PopPK model and model-based simulations were effective means for evaluating aripiprazole lauroxil dosing regimens and management of missed doses. Such analyses play an important role in determining the use of this long-acting antipsychotic in clinical practice.
Karlsson, Kristin; Nyman, Jan; Baumann, Pia; Wersäll, Peter; Drugge, Ninni; Gagliardi, Giovanna; Johansson, Karl-Axel; Persson, Jan-Olov; Rutkowska, Eva; Tullgren, Owe; Lax, Ingmar
2013-11-01
To evaluate the dose-response relationship between radiation-induced atelectasis after stereotactic body radiation therapy (SBRT) and bronchial dose. Seventy-four patients treated with SBRT for tumors close to main, lobar, or segmental bronchi were selected. The association between incidence of atelectasis and bronchial dose parameters (maximum point-dose and minimum dose to the high-dose bronchial volume [ranging from 0.1 cm(3) up to 2.0 cm(3)]) was statistically evaluated with survival analysis models. Prescribed doses varied between 4 and 20 Gy per fraction in 2-5 fractions. Eighteen patients (24.3%) developed atelectasis considered to be radiation-induced. Statistical analysis showed a significant correlation between the incidence of radiation-induced atelectasis and minimum dose to the high-dose bronchial volumes, of which 0.1 cm(3) (D(0.1cm3)) was used for further analysis. The median value of D(0.1cm3) (α/β = 3 Gy) was EQD(2,LQ) = 147 Gy3 (range, 20-293 Gy3). For patients who developed atelectasis the median value was EQD(2,LQ) = 210 Gy3, and for patients who did not develop atelectasis, EQD(2,LQ) = 105 Gy3. Median time from treatment to development of atelectasis was 8.0 months (range, 1.1-30.1 months). In this retrospective study a significant dose-response relationship between the incidence of atelectasis and the dose to the high-dose volume of the bronchi is shown. Copyright © 2013 Elsevier Inc. All rights reserved.
Gafchromic EBT‐XD film: Dosimetry characterization in high‐dose, volumetric‐modulated arc therapy
Ozawa, Shuichi; Hosono, Fumika; Sumida, Naoki; Okazue, Toshiya; Yamada, Kiyoshi; Nagata, Yasushi
2016-01-01
Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT‐XD films have been designed for optimal performance in the 40–4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose‐response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high‐dose volumetric‐modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0–4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter‐free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose‐rate dependence. For clinical examinations, we compared the dose distribution measured with EBT‐XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT‐XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ∼3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ∼1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ∼1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film‐ measured and treatment planning system (TPS)‐calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%. PACS number(s): 87.56 Fc PMID:27929504
Bailiff, I K; Stepanenko, V F; Göksu, H Y; Jungner, H; Balmukhanov, S B; Balmukhanov, T S; Khamidova, L G; Kisilev, V I; Kolyado, I B; Kolizshenkov, T V; Shoikhet, Y N; Tsyb, A F
2004-12-01
Luminescence retrospective dosimetry techniques have been applied with ceramic bricks to determine the cumulative external gamma dose due to fallout, primarily from the 1949 test, in populated regions lying NE of the Semipalatinsk Nuclear Test Site in Altai, Russia, and the Semipalatinsk region, Kazakhstan. As part of a pilot study, nine settlements were examined, three within the regions of highest predicted dose (Dolon in Kazakshstan; Laptev Log and Leshoz Topolinskiy in Russia) and the remainder of lower predicted dose (Akkol, Bolshaya Vladimrovka, Kanonerka, and Izvestka in Kazakshstan; Rubtsovsk and Kuria in Russia) within the lateral regions of the fallout trace due to the 1949 test. The settlement of Kainar, mainly affected by the 24 September 1951 nuclear test, was also examined. The bricks from this region were found to be generally suitable for use with the luminescence method. Estimates of cumulative absorbed dose in air due to fallout for Dolon and Kanonerka in Kazakshstan and Leshoz Topolinskiy were 475 +/- 110 mGy, 240 +/- 60 mGy, and 230 +/- 70 mGy, respectively. The result obtained in Dolon village is in agreement with published calculated estimates of dose normalized to Cs concentration in soil. At all the other locations (except Kainar) the experimental values of cumulative absorbed dose obtained indicated no significant dose due to fallout that could be detected within a margin of about 25 mGy. The results demonstrate the potential suitability of the luminescence method to map variations in cumulative dose within the relatively narrow corridor of fallout distribution from the 1949 test. Such work is needed to provide the basis for accurate dose reconstruction in settlements since the predominance of short-lived radionuclides in the fallout and a high degree of heterogeneity in the distribution of fallout are problematic for the application of conventional dosimetry techniques.
SU-F-T-671: Effects of Collimator Material On Proton Minibeams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, E; Sandison, G; Cao, N
2016-06-15
Purpose: To investigate the dosimetric effects of collimator material on spatially modulated proton minibeams (pMBRT). Methods: pMBRT holds promise to exhibit shallow depth normal-tissue sparing effects similar to synchrotron based microbeams while also retaining potential for uniform dose distributions for tumor targets. TOPAS Monte Carlo simulations were performed for a 5cm thick multislit collimator with 0.3mm slits and 1mm center-to-center spacing for a 50.5MeV proton minibeam while varying collimator material between brass, tungsten, and iron. The collimator was placed both “flush” at the water phantom surface and at 5cm distance to investigate the effects on surface dose, peak-to-valley-dose-ratio (PVDR) andmore » neutron contribution. Results: For flush placement, the neutron dose at the phantom surface for the tungsten collimator was approximately 20% higher than for brass and iron. This was not reflected in the overall surface dose, which was comparable for all materials due to the relatively low neutron contribution of <0.1%. When the collimator was retracted, the overall neutron contribution was essentially identical for all three collimators. Surface dose dropped by ∼40% for all collimator materials with air gap compared to being flush with the phantom surface. This surface dose reduction was at the cost of increase in valley dose for all collimator materials due to increased angular divergence of the mini-beams at the surface and their consequent geometric penumbra at depth. When the collimator was placed at distance from the phantom surface the PVDR decreased. The peak-to-entrance-dose ratio was highest for the iron collimator with 5cm air gap. Conclusion: The dosimetric difference between the collimator materials is minimal despite the relatively higher neutron contribution at the phantom surface for the tungsten collimator when placed flush. The air gap between the collimator and phantom surface strongly influences all dosimetry parameters due to the influence of scatter on the narrow spatial modulation.« less
Manchado de Sola, Francisco; Vilches, Manuel; Prezado, Yolanda; Lallena, Antonio M
2018-05-15
The purpose of this study was to assess the effects of brain movements induced by heartbeat on dose distributions in synchrotron micro- and minibeam radiation therapy and to develop a model to help guide decisions and planning for future clinical trials. The Monte Carlo code PENELOPE was used to simulate the irradiation of a human head phantom with a variety of micro- and minibeam arrays, with beams narrower than 100 μm and above 500 μm, respectively, and with radiation fields of 1 × 2 cm and 2 × 2 cm. The dose in the phantom due to these beams was calculated by superposing the dose profiles obtained for a single beam of 1 μm × 2 cm. A parameter δ, accounting for the total displacement of the brain during the irradiation and due to the cardiosynchronous pulsation, was used to quantify the impact on peak-to-valley dose ratios and the full width at half maximum. The difference between the maximum (at the phantom entrance) and the minimum (at the phantom exit) values of the peak-to-valley dose ratio reduces when the parameter δ increases. The full width at half maximum remains almost constant with depth for any δ value. Sudden changes in the two quantities are observed at the interfaces between the various tissues (brain, skull, and skin) present in the head phantom. The peak-to-valley dose ratio at the center of the head phantom reduces when δ increases, remaining above 70% of the static value only for minibeams and δ smaller than ∼200 μm. Optimal setups for brain treatments with synchrotron radiation micro- and minibeam combs depend on the brain displacement due to cardiosynchronous pulsation. Peak-to-valley dose ratios larger than 90% of the maximum values obtained in the static case occur only for minibeams and relatively large dose rates. © 2018 American Association of Physicists in Medicine.
Earth observations taken from Space Shuttle Columbia during STS-80 mission
1996-11-25
STS080-758-065 (19 Nov.-7 Dec. 1996) --- The island of Oahu, state of Hawaii was photographed by the crew members aboard the Earth-orbiting Space Shuttle Columbia. The western portion (lower part of photograph) of the well eroded extinct volcano is quite clear. The northeastern coastal area and Koolau Range of mountains, which runs the length of the island (30 miles) are cloud covered. This is an unusual case. This is the windward side of the island (great for surfing) and the warm moist Pacific winds sweep up the mountains thus causing the clouds and an unusually high rainfall. The city of Honolulu is along the right side with the Honolulu International Airport clearly seen. Below the airport is the narrow entrance to Pearl Harbor and nearby Hickam Air Force Base. The narrow sand beaches of the Waikiki Beach resort area, just above Diamond Head - on the lower right, appear as narrow white lines along the coast above the airport and port of Honolulu. The sharp point at the lower portion of the photo is Kaena Point. The cliffs there are so steep that there is no developed roadway although a narrow gauge railway was carved into the cliffs and operated the first half of the century.
Khachatryan, V; Sirunyan, A M; Tumasyan, A; Adam, W; Asilar, E; Bergauer, T; Brandstetter, J; Brondolin, E; Dragicevic, M; Erö, J; Flechl, M; Friedl, M; Frühwirth, R; Ghete, V M; Hartl, C; Hörmann, N; Hrubec, J; Jeitler, M; König, A; Krätschmer, I; Liko, D; Matsushita, T; Mikulec, I; Rabady, D; Rad, N; Rahbaran, B; Rohringer, H; Schieck, J; Strauss, J; Treberer-Treberspurg, W; Waltenberger, W; Wulz, C-E; Mossolov, V; Shumeiko, N; Suarez Gonzalez, J; Alderweireldt, S; De Wolf, E A; Janssen, X; Knutsson, A; Lauwers, J; Van De Klundert, M; Van Haevermaet, H; Van Mechelen, P; Van Remortel, N; Van Spilbeeck, A; Abu Zeid, S; Blekman, F; D'Hondt, J; Daci, N; De Bruyn, I; Deroover, K; Heracleous, N; Lowette, S; Moortgat, S; Moreels, L; Olbrechts, A; Python, Q; Tavernier, S; Van Doninck, W; Van Mulders, P; Van Parijs, I; Brun, H; Caillol, C; Clerbaux, B; De Lentdecker, G; Delannoy, H; Fasanella, G; Favart, L; Goldouzian, R; Grebenyuk, A; Karapostoli, G; Lenzi, T; Léonard, A; Luetic, J; Maerschalk, T; Marinov, A; Randle-Conde, A; Seva, T; Vander Velde, C; Vanlaer, P; Yonamine, R; Zenoni, F; Zhang, F; Cimmino, A; Cornelis, T; Dobur, D; Fagot, A; Garcia, G; Gul, M; Mccartin, J; Poyraz, D; Salva, S; Schöfbeck, R; Tytgat, M; Van Driessche, W; Yazgan, E; Zaganidis, N; Beluffi, C; Bondu, O; Brochet, S; Bruno, G; Caudron, A; Ceard, L; De Visscher, S; Delaere, C; Delcourt, M; Forthomme, L; Francois, B; Giammanco, A; Jafari, A; Jez, P; Komm, M; Lemaitre, V; Magitteri, A; Mertens, A; Musich, M; Nuttens, C; Piotrzkowski, K; Quertenmont, L; Selvaggi, M; Vidal Marono, M; Wertz, S; Beliy, N; Aldá Júnior, W L; Alves, F L; Alves, G A; Brito, L; Correa Martins Junior, M; Hensel, C; Moraes, A; Pol, M E; Rebello Teles, P; Belchior Batista Das Chagas, E; Carvalho, W; Chinellato, J; Custódio, A; Da Costa, E M; Da Silveira, G G; De Jesus Damiao, D; De Oliveira Martins, C; Fonseca De Souza, S; Huertas Guativa, L M; Malbouisson, H; Matos Figueiredo, D; Mora Herrera, C; Mundim, L; Nogima, H; Prado Da Silva, W L; Santoro, A; Sznajder, A; Tonelli Manganote, E J; Vilela Pereira, A; Ahuja, S; Bernardes, C A; Dogra, S; Fernandez Perez Tomei, T R; Gregores, E M; Mercadante, P G; Moon, C S; Novaes, S F; Padula, Sandra S; Romero Abad, D; Ruiz Vargas, J C; Aleksandrov, A; Hadjiiska, R; Iaydjiev, P; Rodozov, M; Stoykova, S; Sultanov, G; Vutova, M; Dimitrov, A; Glushkov, I; Litov, L; Pavlov, B; Petkov, P; Fang, W; Ahmad, M; Bian, J G; Chen, G M; Chen, H S; Chen, M; Chen, Y; Cheng, T; Du, R; Jiang, C H; Leggat, D; Liu, Z; Romeo, F; Shaheen, S M; Spiezia, A; Tao, J; Wang, C; Wang, Z; Zhang, H; Zhao, J; Asawatangtrakuldee, C; Ban, Y; Li, Q; Liu, S; Mao, Y; Qian, S J; Wang, D; Xu, Z; Avila, C; Cabrera, A; Chaparro Sierra, L F; Florez, C; Gomez, J P; González Hernández, C F; Ruiz Alvarez, J D; Sanabria, J C; Godinovic, N; Lelas, D; Puljak, I; Ribeiro Cipriano, P M; Antunovic, Z; Kovac, M; Brigljevic, V; Ferencek, D; Kadija, K; Micanovic, S; Sudic, L; Attikis, A; Mavromanolakis, G; Mousa, J; Nicolaou, C; Ptochos, F; Razis, P A; Rykaczewski, H; Finger, M; Finger, M; Carrera Jarrin, E; Elgammal, S; Mohamed, A; Mohammed, Y; Salama, E; Calpas, B; Kadastik, M; Murumaa, M; Perrini, L; Raidal, M; Tiko, A; Veelken, C; Eerola, P; Pekkanen, J; Voutilainen, M; Härkönen, J; Karimäki, V; Kinnunen, R; Lampén, T; Lassila-Perini, K; Lehti, S; Lindén, T; Luukka, P; Peltola, T; Tuominiemi, J; Tuovinen, E; Wendland, L; Talvitie, J; Tuuva, T; Besancon, M; Couderc, F; Dejardin, M; Denegri, D; Fabbro, B; Faure, J L; Favaro, C; Ferri, F; Ganjour, S; Ghosh, S; Givernaud, A; Gras, P; Hamel de Monchenault, G; Jarry, P; Kucher, I; Locci, E; Machet, M; Malcles, J; Rander, J; Rosowsky, A; Titov, M; Zghiche, A; Abdulsalam, A; Antropov, I; Baffioni, S; Beaudette, F; Busson, P; Cadamuro, L; Chapon, E; Charlot, C; Davignon, O; Granier de Cassagnac, R; Jo, M; Lisniak, S; Miné, P; Naranjo, I N; Nguyen, M; Ochando, C; Ortona, G; Paganini, P; Pigard, P; Regnard, S; Salerno, R; Sirois, Y; Strebler, T; Yilmaz, Y; Zabi, A; Agram, J-L; Andrea, J; Aubin, A; Bloch, D; Brom, J-M; Buttignol, M; Chabert, E C; Chanon, N; Collard, C; Conte, E; Coubez, X; Fontaine, J-C; Gelé, D; Goerlach, U; Le Bihan, A-C; Merlin, J A; Skovpen, K; Van Hove, P; Gadrat, S; Beauceron, S; Bernet, C; Boudoul, G; Bouvier, E; Carrillo Montoya, C A; Chierici, R; Contardo, D; Courbon, B; Depasse, P; El Mamouni, H; Fan, J; Fay, J; Gascon, S; Gouzevitch, M; Grenier, G; Ille, B; Lagarde, F; Laktineh, I B; Lethuillier, M; Mirabito, L; Pequegnot, A L; Perries, S; Popov, A; Sabes, D; Sordini, V; Vander Donckt, M; Verdier, P; Viret, S; Toriashvili, T; Lomidze, D; Autermann, C; Beranek, S; Feld, L; Heister, A; Kiesel, M K; Klein, K; Lipinski, M; Ostapchuk, A; Preuten, M; Raupach, F; Schael, S; Schomakers, C; Schulte, J F; Schulz, J; Verlage, T; Weber, H; Zhukov, V; Brodski, M; Dietz-Laursonn, E; Duchardt, D; Endres, M; Erdmann, M; Erdweg, S; Esch, T; Fischer, R; Güth, A; Hebbeker, T; Heidemann, C; Hoepfner, K; Knutzen, S; Merschmeyer, M; Meyer, A; Millet, P; Mukherjee, S; Olschewski, M; Padeken, K; Papacz, P; Pook, T; Radziej, M; Reithler, H; Rieger, M; Scheuch, F; Sonnenschein, L; Teyssier, D; Thüer, S; Cherepanov, V; Erdogan, Y; Flügge, G; Hoehle, F; Kargoll, B; Kress, T; Künsken, A; Lingemann, J; Nehrkorn, A; Nowack, A; Nugent, I M; Pistone, C; Pooth, O; Stahl, A; Aldaya Martin, M; Asin, I; Beernaert, K; Behnke, O; Behrens, U; Bin Anuar, A A; Borras, K; Campbell, A; Connor, P; Contreras-Campana, C; Costanza, F; Diez Pardos, C; Dolinska, G; Eckerlin, G; Eckstein, D; Eichhorn, T; Gallo, E; Garay Garcia, J; Geiser, A; Gizhko, A; Grados Luyando, J M; Gunnellini, P; Harb, A; Hauk, J; Hempel, M; Jung, H; Kalogeropoulos, A; Karacheban, O; Kasemann, M; Keaveney, J; Kieseler, J; Kleinwort, C; Korol, I; Lange, W; Lelek, A; Leonard, J; Lipka, K; Lobanov, A; Lohmann, W; Mankel, R; Melzer-Pellmann, I-A; Meyer, A B; Mittag, G; Mnich, J; Mussgiller, A; Ntomari, E; Pitzl, D; Placakyte, R; Raspereza, A; Roland, B; Sahin, M Ö; Saxena, P; Schoerner-Sadenius, T; Seitz, C; Spannagel, S; Stefaniuk, N; Trippkewitz, K D; Van Onsem, G P; Walsh, R; Wissing, C; Blobel, V; Centis Vignali, M; Draeger, A R; Dreyer, T; Erfle, J; Garutti, E; Goebel, K; Gonzalez, D; Görner, M; Haller, J; Hoffmann, M; Höing, R S; Junkes, A; Klanner, R; Kogler, R; Kovalchuk, N; Lapsien, T; Lenz, T; Marchesini, I; Marconi, D; Meyer, M; Niedziela, M; Nowatschin, D; Ott, J; Pantaleo, F; Peiffer, T; Perieanu, A; Pietsch, N; Poehlsen, J; Sander, C; Scharf, C; Schleper, P; Schlieckau, E; Schmidt, A; Schumann, S; Schwandt, J; Stadie, H; Steinbrück, G; Stober, F M; Stöver, M; Tholen, H; Troendle, D; Usai, E; Vanelderen, L; Vanhoefer, A; Vormwald, B; Barth, C; Baus, C; Berger, J; Butz, E; Chwalek, T; Colombo, F; De Boer, W; Dierlamm, A; Fink, S; Friese, R; Giffels, M; Gilbert, A; Haitz, D; Hartmann, F; Heindl, S M; Husemann, U; Katkov, I; Kornmayer, A; Lobelle Pardo, P; Maier, B; Mildner, H; Mozer, M U; Müller, T; Müller, Th; Plagge, M; Quast, G; Rabbertz, K; Röcker, S; Roscher, F; Schröder, M; Sieber, G; Simonis, H J; Ulrich, R; Wagner-Kuhr, J; Wayand, S; Weber, M; Weiler, T; Williamson, S; Wöhrmann, C; Wolf, R; Anagnostou, G; Daskalakis, G; Geralis, T; Giakoumopoulou, V A; Kyriakis, A; Loukas, D; Topsis-Giotis, I; Agapitos, A; Kesisoglou, S; Panagiotou, A; Saoulidou, N; Tziaferi, E; Evangelou, I; Flouris, G; Foudas, C; Kokkas, P; Loukas, N; Manthos, N; Papadopoulos, I; Paradas, E; Filipovic, N; Bencze, G; Hajdu, C; Hidas, P; Horvath, D; Sikler, F; Veszpremi, V; Vesztergombi, G; Zsigmond, A J; Beni, N; Czellar, S; Karancsi, J; Molnar, J; Szillasi, Z; Bartók, M; Makovec, A; Raics, P; Trocsanyi, Z L; Ujvari, B; Bahinipati, S; Choudhury, S; Mal, P; Mandal, K; Nayak, A; Sahoo, D K; Sahoo, N; Swain, S K; Bansal, S; Beri, S B; Bhatnagar, V; Chawla, R; Gupta, R; Bhawandeep, U; Kalsi, A K; Kaur, A; Kaur, M; Kumar, R; Mehta, A; Mittal, M; Singh, J B; Walia, G; Kumar, Ashok; Bhardwaj, A; Choudhary, B C; Garg, R B; Keshri, S; Kumar, A; Malhotra, S; Naimuddin, M; Nishu, N; Ranjan, K; Sharma, R; Sharma, V; Bhattacharya, R; Bhattacharya, S; Chatterjee, K; Dey, S; Dutt, S; Dutta, S; Ghosh, S; Majumdar, N; Modak, A; Mondal, K; Mukhopadhyay, S; Nandan, S; Purohit, A; Roy, A; Roy, D; Roy Chowdhury, S; Sarkar, S; Sharan, M; Thakur, S; Behera, P K; Chudasama, R; Dutta, D; Jha, V; Kumar, V; Mohanty, A K; Netrakanti, P K; Pant, L M; Shukla, P; Topkar, A; Aziz, T; Dugad, S; Kole, G; Mahakud, B; Mitra, S; Mohanty, G B; Sur, N; Sutar, B; Banerjee, S; Bhowmik, S; Dewanjee, R K; Ganguly, S; Guchait, M; Jain, Sa; Kumar, S; Maity, M; Majumder, G; Mazumdar, K; Parida, B; Sarkar, T; Wickramage, N; Chauhan, S; Dube, S; Kapoor, A; Kothekar, K; Rane, A; Sharma, S; Bakhshiansohi, H; Behnamian, H; Chenarani, S; Eskandari Tadavani, E; Etesami, S M; Fahim, A; Khakzad, M; Mohammadi Najafabadi, M; Naseri, M; Paktinat Mehdiabadi, S; Rezaei Hosseinabadi, F; Safarzadeh, B; Zeinali, M; Felcini, M; Grunewald, M; Abbrescia, M; Calabria, C; Caputo, C; Colaleo, A; Creanza, D; Cristella, L; De Filippis, N; De Palma, M; Fiore, L; Iaselli, G; Maggi, G; Maggi, M; Miniello, G; My, S; Nuzzo, S; Pompili, A; Pugliese, G; Radogna, R; Ranieri, A; Selvaggi, G; Silvestris, L; Venditti, R; Abbiendi, G; Battilana, C; Bonacorsi, D; Braibant-Giacomelli, S; Brigliadori, L; Campanini, R; Capiluppi, P; Castro, A; Cavallo, F R; Chhibra, S S; Codispoti, G; Cuffiani, M; Dallavalle, G M; Fabbri, F; Fanfani, A; Fasanella, D; Giacomelli, P; Grandi, C; Guiducci, L; Marcellini, S; Masetti, G; Montanari, A; Navarria, F L; Perrotta, A; Rossi, A M; Rovelli, T; Siroli, G P; Tosi, N; Albergo, S; Chiorboli, M; Costa, S; Di Mattia, A; Giordano, F; Potenza, R; Tricomi, A; Tuve, C; Barbagli, G; Ciulli, V; Civinini, C; D'Alessandro, R; Focardi, E; Gori, V; Lenzi, P; Meschini, M; Paoletti, S; Sguazzoni, G; Viliani, L; Benussi, L; Bianco, S; Fabbri, F; Piccolo, D; Primavera, F; Calvelli, V; Ferro, F; Lo Vetere, M; Monge, M R; Robutti, E; Tosi, S; Brianza, L; Dinardo, M E; Fiorendi, S; Gennai, S; Ghezzi, A; Govoni, P; Malvezzi, S; Manzoni, R A; Marzocchi, B; Menasce, D; Moroni, L; Paganoni, M; Pedrini, D; Pigazzini, S; Ragazzi, S; Tabarelli de Fatis, T; Buontempo, S; Cavallo, N; De Nardo, G; Di Guida, S; Esposito, M; Fabozzi, F; Iorio, A O M; Lanza, G; Lista, L; Meola, S; Merola, M; Paolucci, P; Sciacca, C; Thyssen, F; Azzi, P; Bacchetta, N; Benato, L; Bisello, D; Boletti, A; Carlin, R; Carvalho Antunes De Oliveira, A; Checchia, P; Dall'Osso, M; De Castro Manzano, P; Dorigo, T; Dosselli, U; Gasparini, F; Gasparini, U; Gozzelino, A; Lacaprara, S; Margoni, M; Meneguzzo, A T; Pazzini, J; Pozzobon, N; Ronchese, P; Simonetto, F; Torassa, E; Tosi, M; Zanetti, M; Zotto, P; Zucchetta, A; Zumerle, G; Braghieri, A; Magnani, A; Montagna, P; Ratti, S P; Re, V; Riccardi, C; Salvini, P; Vai, I; Vitulo, P; Alunni Solestizi, L; Bilei, G M; Ciangottini, D; Fanò, L; Lariccia, P; Leonardi, R; Mantovani, G; Menichelli, M; Saha, A; Santocchia, A; Androsov, K; Azzurri, P; Bagliesi, G; Bernardini, J; Boccali, T; Castaldi, R; Ciocci, M A; Dell'Orso, R; Donato, S; Fedi, G; Giassi, A; Grippo, M T; Ligabue, F; Lomtadze, T; Martini, L; Messineo, A; Palla, F; Rizzi, A; Savoy-Navarro, A; Spagnolo, P; Tenchini, R; Tonelli, G; Venturi, A; Verdini, P G; Barone, L; Cavallari, F; Cipriani, M; D'imperio, G; Del Re, D; Diemoz, M; Gelli, S; Jorda, C; Longo, E; Margaroli, F; Meridiani, P; Organtini, G; Paramatti, R; Preiato, F; Rahatlou, S; Rovelli, C; Santanastasio, F; Amapane, N; Arcidiacono, R; Argiro, S; Arneodo, M; Bartosik, N; Bellan, R; Biino, C; Cartiglia, N; Costa, M; Covarelli, R; Degano, A; Demaria, N; Finco, L; Kiani, B; Mariotti, C; Maselli, S; Migliore, E; Monaco, V; Monteil, E; Obertino, M M; Pacher, L; Pastrone, N; Pelliccioni, M; Pinna Angioni, G L; Ravera, F; Romero, A; Ruspa, M; Sacchi, R; Shchelina, K; Sola, V; Solano, A; Staiano, A; Traczyk, P; Belforte, S; Candelise, V; Casarsa, M; Cossutti, F; Della Ricca, G; La Licata, C; Schizzi, A; Zanetti, A; Kim, D H; Kim, G N; Kim, M S; Lee, S; Lee, S W; Oh, Y D; Sekmen, S; Son, D C; Yang, Y C; Kim, H; Lee, A; Brochero Cifuentes, J A; Kim, T J; Cho, S; Choi, S; Go, Y; Gyun, D; Ha, S; Hong, B; Jo, Y; Kim, Y; Lee, B; Lee, K; Lee, K S; Lee, S; Lim, J; Park, S K; Roh, Y; Almond, J; Kim, J; Oh, S B; Seo, S H; Yang, U K; Yoo, H D; Yu, G B; Choi, M; Kim, H; Kim, H; Kim, J H; Lee, J S H; Park, I C; Ryu, G; Ryu, M S; Choi, Y; Goh, J; Kim, D; Kwon, E; Lee, J; Yu, I; Dudenas, V; Juodagalvis, A; Vaitkus, J; Ahmed, I; Ibrahim, Z A; Komaragiri, J R; Md Ali, M A B; Mohamad Idris, F; Wan Abdullah, W A T; Yusli, M N; Zolkapli, Z; Casimiro Linares, E; Castilla-Valdez, H; De La Cruz-Burelo, E; Heredia-De La Cruz, I; Hernandez-Almada, A; Lopez-Fernandez, R; Mejia Guisao, J; Sanchez-Hernandez, A; Carrillo Moreno, S; Vazquez Valencia, F; Pedraza, I; Salazar Ibarguen, H A; Uribe Estrada, C; Morelos Pineda, A; Krofcheck, D; Butler, P H; Ahmad, A; Ahmad, M; Hassan, Q; Hoorani, H R; Khan, W A; Qazi, S; Shoaib, M; Waqas, M; Bialkowska, H; Bluj, M; Boimska, B; Frueboes, T; Górski, M; Kazana, M; Nawrocki, K; Romanowska-Rybinska, K; Szleper, M; Zalewski, P; Bunkowski, K; Byszuk, A; Doroba, K; Kalinowski, A; Konecki, M; Krolikowski, J; Misiura, M; Olszewski, M; Walczak, M; Bargassa, P; Beirão Da Cruz E Silva, C; Di Francesco, A; Faccioli, P; Ferreira Parracho, P G; Gallinaro, M; Hollar, J; Leonardo, N; Lloret Iglesias, L; Nemallapudi, M V; Rodrigues Antunes, J; Seixas, J; Toldaiev, O; Vadruccio, D; Varela, J; Vischia, P; Bunin, P; Gavrilenko, M; Golutvin, I; Gorbounov, N; Gorbunov, I; Karjavin, V; Kozlov, G; Lanev, A; Malakhov, A; Matveev, V; Moisenz, P; Palichik, V; Perelygin, V; Savina, M; Shmatov, S; Shulha, S; Skatchkov, N; Smirnov, V; Zarubin, A; Chtchipounov, L; Golovtsov, V; Ivanov, Y; Kim, V; Kuznetsova, E; Murzin, V; Oreshkin, V; Sulimov, V; Vorobyev, A; Andreev, Yu; Dermenev, A; Gninenko, S; Golubev, N; Karneyeu, A; Kirsanov, M; Krasnikov, N; Pashenkov, A; Tlisov, D; Toropin, A; Epshteyn, V; Gavrilov, V; Lychkovskaya, N; Popov, V; Pozdnyakov, I; Safronov, G; Spiridonov, A; Toms, M; Vlasov, E; Zhokin, A; Chadeeva, M; Danilov, M; Zhemchugov, E; Andreev, V; Azarkin, M; Dremin, I; Kirakosyan, M; Leonidov, A; Rusakov, S V; Terkulov, A; Baskakov, A; Belyaev, A; Boos, E; Dubinin, M; Dudko, L; Ershov, A; Gribushin, A; Klyukhin, V; Kodolova, O; Lokhtin, I; Miagkov, I; Obraztsov, S; Petrushanko, S; Savrin, V; Snigirev, A; Azhgirey, I; Bayshev, I; Bitioukov, S; Elumakhov, D; Kachanov, V; Kalinin, A; Konstantinov, D; Krychkine, V; Petrov, V; Ryutin, R; Sobol, A; Troshin, S; Tyurin, N; Uzunian, A; Volkov, A; Adzic, P; Cirkovic, P; Devetak, D; Milosevic, J; Rekovic, V; Alcaraz Maestre, J; Calvo, E; Cerrada, M; Chamizo Llatas, M; Colino, N; De La Cruz, B; Delgado Peris, A; Escalante Del Valle, A; Fernandez Bedoya, C; Fernández Ramos, J P; Flix, J; Fouz, M C; Garcia-Abia, P; Gonzalez Lopez, O; Goy Lopez, S; Hernandez, J M; Josa, M I; Navarro De Martino, E; Pérez-Calero Yzquierdo, A; Puerta Pelayo, J; Quintario Olmeda, A; Redondo, I; Romero, L; Soares, M S; de Trocóniz, J F; Missiroli, M; Moran, D; Cuevas, J; Fernandez Menendez, J; Gonzalez Caballero, I; Palencia Cortezon, E; Sanchez Cruz, S; Vizan Garcia, J M; Cabrillo, I J; Calderon, A; Castiñeiras De Saa, J R; Curras, E; Fernandez, M; Garcia-Ferrero, J; Gomez, G; Lopez Virto, A; Marco, J; Martinez Rivero, C; Matorras, F; Piedra Gomez, J; Rodrigo, T; Ruiz-Jimeno, A; Scodellaro, L; Trevisani, N; Vila, I; Vilar Cortabitarte, R; Abbaneo, D; Auffray, E; Auzinger, G; Bachtis, M; Baillon, P; Ball, A H; Barney, D; Bloch, P; Bocci, A; Bonato, A; Botta, C; Camporesi, T; Castello, R; Cepeda, M; Cerminara, G; D'Alfonso, M; d'Enterria, D; Dabrowski, A; Daponte, V; David, A; De Gruttola, M; De Guio, F; De Roeck, A; Di Marco, E; Dobson, M; Dordevic, M; Dorney, B; du Pree, T; Duggan, D; Dünser, M; Dupont, N; Elliott-Peisert, A; Fartoukh, S; Franzoni, G; Fulcher, J; Funk, W; Gigi, D; Gill, K; Girone, M; Glege, F; Gundacker, S; Guthoff, M; Hammer, J; Harris, P; Hegeman, J; Innocente, V; Janot, P; Kirschenmann, H; Knünz, V; Kortelainen, M J; Kousouris, K; Krammer, M; Lecoq, P; Lourenço, C; Lucchini, M T; Magini, N; Malgeri, L; Mannelli, M; Martelli, A; Meijers, F; Mersi, S; Meschi, E; Moortgat, F; Morovic, S; Mulders, M; Neugebauer, H; Orfanelli, S; Orsini, L; Pape, L; Perez, E; Peruzzi, M; Petrilli, A; Petrucciani, G; Pfeiffer, A; Pierini, M; Racz, A; Reis, T; Rolandi, G; Rovere, M; Ruan, M; Sakulin, H; Sauvan, J B; Schäfer, C; Schwick, C; Seidel, M; Sharma, A; Silva, P; Simon, M; Sphicas, P; Steggemann, J; Stoye, M; Takahashi, Y; Treille, D; Triossi, A; Tsirou, A; Veckalns, V; Veres, G I; Wardle, N; Zagozdzinska, A; Zeuner, W D; Bertl, W; Deiters, K; Erdmann, W; Horisberger, R; Ingram, Q; Kaestli, H C; Kotlinski, D; Langenegger, U; Rohe, T; Bachmair, F; Bäni, L; Bianchini, L; Casal, B; Dissertori, G; Dittmar, M; Donegà, M; Eller, P; Grab, C; Heidegger, C; Hits, D; Hoss, J; Kasieczka, G; Lecomte, P; Lustermann, W; Mangano, B; Marionneau, M; Martinez Ruiz Del Arbol, P; Masciovecchio, M; Meinhard, M T; Meister, D; Micheli, F; Musella, P; Nessi-Tedaldi, F; Pandolfi, F; Pata, J; Pauss, F; Perrin, G; Perrozzi, L; Quittnat, M; Rossini, M; Schönenberger, M; Starodumov, A; Takahashi, M; Tavolaro, V R; Theofilatos, K; Wallny, R; Aarrestad, T K; Amsler, C; Caminada, L; Canelli, M F; Chiochia, V; De Cosa, A; Galloni, C; Hinzmann, A; Hreus, T; Kilminster, B; Lange, C; Ngadiuba, J; Pinna, D; Rauco, G; Robmann, P; Salerno, D; Yang, Y; Doan, T H; Jain, Sh; Khurana, R; Konyushikhin, M; Kuo, C M; Lin, W; Lu, Y J; Pozdnyakov, A; Yu, S S; Kumar, Arun; Chang, P; Chang, Y H; Chang, Y W; Chao, Y; Chen, K F; Chen, P H; Dietz, C; Fiori, F; Hou, W-S; Hsiung, Y; Liu, Y F; Lu, R-S; Miñano Moya, M; Paganis, E; Psallidas, A; Tsai, J F; Tzeng, Y M; Asavapibhop, B; Singh, G; Srimanobhas, N; Suwonjandee, N; Adiguzel, A; Cerci, S; Damarseckin, S; Demiroglu, Z S; Dozen, C; Dumanoglu, I; Girgis, S; Gokbulut, G; Guler, Y; Gurpinar, E; Hos, I; Kangal, E E; Onengut, G; Ozdemir, K; Sunar Cerci, D; Tali, B; Topakli, H; Zorbilmez, C; Bilin, B; Bilmis, S; Isildak, B; Karapinar, G; Yalvac, M; Zeyrek, M; Gülmez, E; Kaya, M; Kaya, O; Yetkin, E A; Yetkin, T; Cakir, A; Cankocak, K; Sen, S; Vardarlı, F I; Grynyov, B; Levchuk, L; Sorokin, P; Aggleton, R; Ball, F; Beck, L; Brooke, J J; Burns, D; Clement, E; Cussans, D; Flacher, H; Goldstein, J; Grimes, M; Heath, G P; Heath, H F; Jacob, J; Kreczko, L; Lucas, C; Meng, Z; Newbold, D M; Paramesvaran, S; Poll, A; Sakuma, T; Seif El Nasr-Storey, S; Senkin, S; Smith, D; Smith, V J; Bell, K W; Belyaev, A; Brew, C; Brown, R M; Calligaris, L; Cieri, D; Cockerill, D J A; Coughlan, J A; Harder, K; Harper, S; Olaiya, E; Petyt, D; Shepherd-Themistocleous, C H; Thea, A; Tomalin, I R; Williams, T; Baber, M; Bainbridge, R; Buchmuller, O; Bundock, A; Burton, D; Casasso, S; Citron, M; Colling, D; Corpe, L; Dauncey, P; Davies, G; De Wit, A; Della Negra, M; Dunne, P; Elwood, A; Futyan, D; Haddad, Y; Hall, G; Iles, G; Lane, R; Laner, C; Lucas, R; Lyons, L; Magnan, A-M; Malik, S; Mastrolorenzo, L; Nash, J; Nikitenko, A; Pela, J; Penning, B; Pesaresi, M; Raymond, D M; Richards, A; Rose, A; Seez, C; Tapper, A; Uchida, K; Vazquez Acosta, M; Virdee, T; Zenz, S C; Cole, J E; Hobson, P R; Khan, A; Kyberd, P; Leslie, D; Reid, I D; Symonds, P; Teodorescu, L; Turner, M; Borzou, A; Call, K; Dittmann, J; Hatakeyama, K; Liu, H; Pastika, N; Charaf, O; Cooper, S I; Henderson, C; Rumerio, P; Arcaro, D; Avetisyan, A; Bose, T; Gastler, D; Rankin, D; Richardson, C; Rohlf, J; Sulak, L; Zou, D; Benelli, G; Berry, E; Cutts, D; Ferapontov, A; Garabedian, A; Hakala, J; Heintz, U; Jesus, O; Laird, E; Landsberg, G; Mao, Z; Narain, M; Piperov, S; Sagir, S; Spencer, E; Syarif, R; Breedon, R; Breto, G; Burns, D; Calderon De La Barca Sanchez, M; Chauhan, S; Chertok, M; Conway, J; Conway, R; Cox, P T; Erbacher, R; Flores, C; Funk, G; Gardner, M; Ko, W; Lander, R; Mclean, C; Mulhearn, M; Pellett, D; Pilot, J; Ricci-Tam, F; Shalhout, S; Smith, J; Squires, M; Stolp, D; Tripathi, M; Wilbur, S; Yohay, R; Cousins, R; Everaerts, P; Florent, A; Hauser, J; Ignatenko, M; Saltzberg, D; Takasugi, E; Valuev, V; Weber, M; Burt, K; Clare, R; Ellison, J; Gary, J W; Hanson, G; Heilman, J; Jandir, P; Kennedy, E; Lacroix, F; Long, O R; Malberti, M; Olmedo Negrete, M; Paneva, M I; Shrinivas, A; Wei, H; Wimpenny, S; Yates, B R; Branson, J G; Cerati, G B; Cittolin, S; D'Agnolo, R T; Derdzinski, M; Gerosa, R; Holzner, A; Kelley, R; Klein, D; Letts, J; Macneill, I; Olivito, D; Padhi, S; Pieri, M; Sani, M; Sharma, V; Simon, S; Tadel, M; Vartak, A; Wasserbaech, S; Welke, C; Wood, J; Würthwein, F; Yagil, A; Zevi Della Porta, G; Bhandari, R; Bradmiller-Feld, J; Campagnari, C; Dishaw, A; Dutta, V; Flowers, K; Franco Sevilla, M; Geffert, P; George, C; Golf, F; Gouskos, L; Gran, J; Heller, R; Incandela, J; Mccoll, N; Mullin, S D; Ovcharova, A; Richman, J; Stuart, D; Suarez, I; West, C; Yoo, J; Anderson, D; Apresyan, A; Bendavid, J; Bornheim, A; Bunn, J; Chen, Y; Duarte, J; Mott, A; Newman, H B; Pena, C; Spiropulu, M; Vlimant, J R; Xie, S; Zhu, R Y; Andrews, M B; Azzolini, V; Calamba, A; Carlson, B; Ferguson, T; Paulini, M; Russ, J; Sun, M; Vogel, H; Vorobiev, I; Cumalat, J P; Ford, W T; Jensen, F; Johnson, A; Krohn, M; Mulholland, T; Stenson, K; Wagner, S R; Alexander, J; Chaves, J; Chu, J; Dittmer, S; Mirman, N; Nicolas Kaufman, G; Patterson, J R; Rinkevicius, A; Ryd, A; Skinnari, L; Sun, W; Tan, S M; Tao, Z; Thom, J; Tucker, J; Wittich, P; Winn, D; Abdullin, S; Albrow, M; Apollinari, G; Banerjee, S; Bauerdick, L A T; Beretvas, A; Berryhill, J; Bhat, P C; Bolla, G; Burkett, K; Butler, J N; Cheung, H W K; Chlebana, F; Cihangir, S; Cremonesi, M; Elvira, V D; Fisk, I; Freeman, J; Gottschalk, E; Gray, L; Green, D; Grünendahl, S; Gutsche, O; Hare, D; Harris, R M; Hasegawa, S; Hirschauer, J; Hu, Z; Jayatilaka, B; Jindariani, S; Johnson, M; Joshi, U; Klima, B; Kreis, B; Lammel, S; Linacre, J; Lincoln, D; Lipton, R; Liu, T; Lopes De Sá, R; Lykken, J; Maeshima, K; Marraffino, J M; Maruyama, S; Mason, D; McBride, P; Merkel, P; Mrenna, S; Nahn, S; Newman-Holmes, C; O'Dell, V; Pedro, K; Prokofyev, O; Rakness, G; Ristori, L; Sexton-Kennedy, E; Soha, A; Spalding, W J; Spiegel, L; Stoynev, S; Strobbe, N; Taylor, L; Tkaczyk, S; Tran, N V; Uplegger, L; Vaandering, E W; Vernieri, C; Verzocchi, M; Vidal, R; Wang, M; Weber, H A; Whitbeck, A; Acosta, D; Avery, P; Bortignon, P; Bourilkov, D; Brinkerhoff, A; Carnes, A; Carver, M; Curry, D; Das, S; Field, R D; Furic, I K; Konigsberg, J; Korytov, A; Ma, P; Matchev, K; Mei, H; Milenovic, P; Mitselmakher, G; Rank, D; Shchutska, L; Sperka, D; Thomas, L; Wang, J; Wang, S; Yelton, J; Linn, S; Markowitz, P; Martinez, G; Rodriguez, J L; Ackert, A; Adams, J R; Adams, T; Askew, A; Bein, S; Diamond, B; Hagopian, S; Hagopian, V; Johnson, K F; Khatiwada, A; Prosper, H; Santra, A; Weinberg, M; Baarmand, M M; Bhopatkar, V; Colafranceschi, S; Hohlmann, M; Kalakhety, H; Noonan, D; Roy, T; Yumiceva, F; Adams, M R; Apanasevich, L; Berry, D; Betts, R R; Bucinskaite, I; Cavanaugh, R; Evdokimov, O; Gauthier, L; Gerber, C E; Hofman, D J; Kurt, P; O'Brien, C; Sandoval Gonzalez, I D; Turner, P; Varelas, N; Wu, Z; Zakaria, M; Zhang, J; Bilki, B; Clarida, W; Dilsiz, K; Durgut, S; Gandrajula, R P; Haytmyradov, M; Khristenko, V; Merlo, J-P; Mermerkaya, H; Mestvirishvili, A; Moeller, A; Nachtman, J; Ogul, H; Onel, Y; Ozok, F; Penzo, A; Snyder, C; Tiras, E; Wetzel, J; Yi, K; Anderson, I; Blumenfeld, B; Cocoros, A; Eminizer, N; Fehling, D; Feng, L; Gritsan, A V; Maksimovic, P; Osherson, M; Roskes, J; Sarica, U; Swartz, M; Xiao, M; Xin, Y; You, C; Al-Bataineh, A; Baringer, P; Bean, A; Bowen, J; Bruner, C; Castle, J; Kenny, R P; Kropivnitskaya, A; Majumder, D; Mcbrayer, W; Murray, M; Sanders, S; Stringer, R; Tapia Takaki, J D; Wang, Q; Ivanov, A; Kaadze, K; Khalil, S; Makouski, M; Maravin, Y; Mohammadi, A; Saini, L K; Skhirtladze, N; Toda, S; Lange, D; Rebassoo, F; Wright, D; Anelli, C; Baden, A; Baron, O; Belloni, A; Calvert, B; Eno, S C; Ferraioli, C; Gomez, J A; Hadley, N J; Jabeen, S; Kellogg, R G; Kolberg, T; Kunkle, J; Lu, Y; Mignerey, A C; Shin, Y H; Skuja, A; Tonjes, M B; Tonwar, S C; Apyan, A; Barbieri, R; Baty, A; Bi, R; Bierwagen, K; Brandt, S; Busza, W; Cali, I A; Demiragli, Z; Di Matteo, L; Gomez Ceballos, G; Goncharov, M; Gulhan, D; Hsu, D; Iiyama, Y; Innocenti, G M; Klute, M; Kovalskyi, D; Krajczar, K; Lai, Y S; Lee, Y-J; Levin, A; Luckey, P D; Marini, A C; Mcginn, C; Mironov, C; Narayanan, S; Niu, X; Paus, C; Roland, C; Roland, G; Salfeld-Nebgen, J; Stephans, G S F; Sumorok, K; Tatar, K; Varma, M; Velicanu, D; Veverka, J; Wang, J; Wang, T W; Wyslouch, B; Yang, M; Zhukova, V; Benvenuti, A C; Chatterjee, R M; Dahmes, B; Evans, A; Finkel, A; Gude, A; Hansen, P; Kalafut, S; Kao, S C; Klapoetke, K; Kubota, Y; Lesko, Z; Mans, J; Nourbakhsh, S; Ruckstuhl, N; Rusack, R; Tambe, N; Turkewitz, J; Acosta, J G; Oliveros, S; Avdeeva, E; Bartek, R; Bloom, K; Bose, S; Claes, D R; Dominguez, A; Fangmeier, C; Gonzalez Suarez, R; Kamalieddin, R; Knowlton, D; Kravchenko, I; Meier, F; Monroy, J; Siado, J E; Snow, G R; Stieger, B; Alyari, M; Dolen, J; George, J; Godshalk, A; Harrington, C; Iashvili, I; Kaisen, J; Kharchilava, A; Kumar, A; Parker, A; Rappoccio, S; Roozbahani, B; Alverson, G; Barberis, E; Baumgartel, D; Chasco, M; Hortiangtham, A; Massironi, A; Morse, D M; Nash, D; Orimoto, T; Teixeira De Lima, R; Trocino, D; Wang, R-J; Wood, D; Bhattacharya, S; Hahn, K A; Kubik, A; Low, J F; Mucia, N; Odell, N; Pollack, B; Schmitt, M H; Sung, K; Trovato, M; Velasco, M; Dev, N; Hildreth, M; Hurtado Anampa, K; Jessop, C; Karmgard, D J; Kellams, N; Lannon, K; Marinelli, N; Meng, F; Mueller, C; Musienko, Y; Planer, M; Reinsvold, A; Ruchti, R; Rupprecht, N; Smith, G; Taroni, S; Valls, N; Wayne, M; Wolf, M; Woodard, A; Alimena, J; Antonelli, L; Brinson, J; Bylsma, B; Durkin, L S; Flowers, S; Francis, B; Hart, A; Hill, C; Hughes, R; Ji, W; Liu, B; Luo, W; Puigh, D; Rodenburg, M; Winer, B L; Wulsin, H W; Cooperstein, S; Driga, O; Elmer, P; Hardenbrook, J; Hebda, P; Luo, J; Marlow, D; Medvedeva, T; Mooney, M; Olsen, J; Palmer, C; Piroué, P; Stickland, D; Tully, C; Zuranski, A; Malik, S; Barker, A; Barnes, V E; Benedetti, D; Folgueras, S; Gutay, L; Jha, M K; Jones, M; Jung, A W; Jung, K; Miller, D H; Neumeister, N; Radburn-Smith, B C; Shi, X; Sun, J; Svyatkovskiy, A; Wang, F; Xie, W; Xu, L; Parashar, N; Stupak, J; Adair, A; Akgun, B; Chen, Z; Ecklund, K M; Geurts, F J M; Guilbaud, M; Li, W; Michlin, B; Northup, M; Padley, B P; Redjimi, R; Roberts, J; Rorie, J; Tu, Z; Zabel, J; Betchart, B; Bodek, A; de Barbaro, P; Demina, R; Duh, Y T; Ferbel, T; Galanti, M; Garcia-Bellido, A; Han, J; Hindrichs, O; Khukhunaishvili, A; Lo, K H; Tan, P; Verzetti, M; Chou, J P; Contreras-Campana, E; Gershtein, Y; Gómez Espinosa, T A; Halkiadakis, E; Heindl, M; Hidas, D; Hughes, E; Kaplan, S; Kunnawalkam Elayavalli, R; Kyriacou, S; Lath, A; Nash, K; Saka, H; Salur, S; Schnetzer, S; Sheffield, D; Somalwar, S; Stone, R; Thomas, S; Thomassen, P; Walker, M; Foerster, M; Heideman, J; Riley, G; Rose, K; Spanier, S; Thapa, K; Bouhali, O; Castaneda Hernandez, A; Celik, A; Dalchenko, M; De Mattia, M; Delgado, A; Dildick, S; Eusebi, R; Gilmore, J; Huang, T; Juska, E; Kamon, T; Krutelyov, V; Mueller, R; Pakhotin, Y; Patel, R; Perloff, A; Perniè, L; Rathjens, D; Rose, A; Safonov, A; Tatarinov, A; Ulmer, K A; Akchurin, N; Cowden, C; Damgov, J; Dragoiu, C; Dudero, P R; Faulkner, J; Kunori, S; Lamichhane, K; Lee, S W; Libeiro, T; Undleeb, S; Volobouev, I; Wang, Z; Delannoy, A G; Greene, S; Gurrola, A; Janjam, R; Johns, W; Maguire, C; Melo, A; Ni, H; Sheldon, P; Tuo, S; Velkovska, J; Xu, Q; Arenton, M W; Barria, P; Cox, B; Goodell, J; Hirosky, R; Ledovskoy, A; Li, H; Neu, C; Sinthuprasith, T; Sun, X; Wang, Y; Wolfe, E; Xia, F; Clarke, C; Harr, R; Karchin, P E; Lamichhane, P; Sturdy, J; Belknap, D A; Dasu, S; Dodd, L; Duric, S; Gomber, B; Grothe, M; Herndon, M; Hervé, A; Klabbers, P; Lanaro, A; Levine, A; Long, K; Loveless, R; Ojalvo, I; Perry, T; Pierro, G A; Polese, G; Ruggles, T; Savin, A; Sharma, A; Smith, N; Smith, W H; Taylor, D; Verwilligen, P; Woods, N
2016-07-15
A search for narrow resonances decaying into dijet final states is performed on data from proton-proton collisions at a center-of-mass energy of 8 TeV, corresponding to an integrated luminosity of 18.8 fb^{-1}. The data were collected with the CMS detector using a novel technique called data scouting, in which the information associated with these selected events is much reduced, permitting collection of larger data samples. This technique enables CMS to record events containing jets at a rate of 1 kHz, by collecting the data from the high-level-trigger system. In this way, the sensitivity to low-mass resonances is increased significantly, allowing previously inaccessible couplings of new resonances to quarks and gluons to be probed. The resulting dijet mass distribution yields no evidence of narrow resonances. Upper limits are presented on the resonance cross sections as a function of mass, and compared with a variety of models predicting narrow resonances. The limits are translated into upper limits on the coupling of a leptophobic resonance Z_{B}^{'} to quarks, improving on the results obtained by previous experiments for the mass range from 500 to 800 GeV.
Khachatryan, Vardan
2016-07-14
A search for narrow resonances decaying into dijet final states is performed on data from proton-proton collisions at a center-of-mass energy of 8 TeV, corresponding to an integrated luminosity of 18.8 fb -1. The data were collected with the CMS detector using a novel technique called data scouting, in which the information associated with these selected events is much reduced, permitting collection of larger data samples. This technique enables CMS to record events containing jets at a rate of 1 kHz, by collecting the data from the high-level-trigger system. In this way, the sensitivity to low-mass resonances is increased significantly, allowing previouslymore » inaccessible couplings of new resonances to quarks and gluons to be probed. The resulting dijet mass distribution yields no evidence of narrow resonances. Upper limits are presented on the resonance cross sections as a function of mass, and compared with a variety of models predicting narrow resonances. Furthermore, the limits are translated into upper limits on the coupling of a leptophobic resonance Z' B to quarks, improving on the results obtained by previous experiments for the mass range from 500 to 800 GeV.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moteabbed, M; Trofimov, A; Testa, M
2014-06-01
Purpose: With the anticipated introduction of in vivo range verification methods, the use of anterior fields for proton therapy of prostate cancer may become an attractive treatment option, and improve upon the dose distributions achievable with conventional lateral-opposed fields. This study aimed to evaluate and compare the planned dose accuracy for lateral versus anterior oblique field arrangements. Methods: Four patients with low/intermediate risk prostate cancer, participating in a clinical trial at our institution, were selected for this study. All patients were treated using lateral-opposed fields (LAT). The clinical target volume (CTV) received a total dose of 79.2 Gy in 44more » fractions. Anterior oblique research plans (ANT) were created using the clinical planning system, and featured beams with ±35-degree gantry angle, 1.2 cm aperture margins, 3-mm range compensator smearing and no range uncertainty margins. Monte Carlo (MC) simulations were performed for both beam arrangements using TOPAS. Dose volume histograms were analyzed and compared for planned and MC dose distributions. Differences between MC and planned DVH parameters were computed as a percentage of the total prescribed dose. Results: For all patients, CTV dose was systematically lower (∼2–2.5%) for MC than the plan. This discrepancy was slightly larger (∼0.5%) for LAT compared to ANT plans for all cases. Although the dose differences for bladder and anterior rectal wall remained within 0.7% for all LAT cases, they were slightly larger for ANT plans, especially for case 3 due to larger patient size and MC-plan range difference. The EUD difference for femoral heads was within 0.6% for both LAT and ANT cases. Conclusion: The dose calculated by the treatment planning system using pencil beam algorithm agrees with MC to within 2.5% and is comparable for lateral and anterior scenarios. The dose agreement in the anterior rectal wall is range- and hence, patient-dependent for ANT treatments.« less
Competitive Electricity Prices: An Update
1998-01-01
Illustrates a third impact of the move to competitive generation pricing -- the narrowing of the range of prices across regions of the country. This feature article updates information in Electricity Prices in a Competitive Environment: Marginal Cost Pricing of Generation Services and Financial Status of Electric Utilities.
NEW ADVANCES IN BORON SOIL CHEMISTRY
Boron is an essential plant micronutrient for which the range between deficiency and toxicity is narrower than for any other nutrient element. Plants respond directly to the amount of B in soil solution and only indirectly to the amount of B adsorbed on soil particle surfaces. ...
NEW ADVANCES IN BORON SOIL CHEMISTRY - Paper
Boron is an essential plant micronutrient for which the range between deficiency and toxicity is narrower than for any other nutrient element. Plants respond directly to the amount of B in soil solution and only indirectly to the amount of B adsorbed on soil particle surfaces. ...
Wedge measures parallax separations...on large-scale 70-mm
Steven L. Wert; Richard J. Myhre
1967-01-01
A new parallax wedge (range: 1.5 to 2 inches) has been designed for use with large-scaled 70-mm. aerial photographs. The narrow separation of the wedge allows the user to measure small parallax separations that are characteristic of large-scale photographs.
DNA Polymorphism Among American Watermelon Cultivars Based on DNA Methylation
USDA-ARS?s Scientific Manuscript database
American watermelon heirlooms are diverse in their growth habits, fruit qualities and responses to biotic and abiotic stress. Wide ranging DNA marker tools resolved a narrow molecular diversity among these collections. The current research explored additional insights such as extent of diversity a...
Effect of comfort pads and incubator design on neonatal radiography.
Jiang, Xia; Baad, Michael; Reiser, Ingrid; Feinstein, Kate A; Lu, Zhengfeng
2016-01-01
There has been increasing interest in patient dose reduction in neonatal intensive care units. Removing comfort pads for radiography has been identified as a potential means to decrease patient dose. To assess the effect of comfort pads and support trays on detector entrance exposure (DEE) and image quality for neonatal radiography, and its implication for patient dose. Comfort pads and support trays from three incubator and warmer systems were examined. The attenuation of the primary beam by these structures was measured using a narrow beam geometry. Their effect on DEE and image quality was then assessed using typical neonatal chest radiography techniques with three configurations: 1) both the comfort pad and support included in the beam, 2) only the support tray included and 3) both the comfort pad and support tray removed. Comfort pads and support trays were found to attenuate the primary beam by 6-15%. Eliminating these structures from the X-ray beam's path was found to increase the detector entrance exposure by 28-36% and increase contrast-to-noise ratio by more than 21%, suggesting room for patient dose reduction when the same image quality is maintained. Comfort pads and tray support devices can have a considerable effect on DEE and image quality, with large variations among different incubator designs. Positioning the image detector directly underneath neonatal patients for radiography is a potential means for patient dose reduction. However, such benefit should be weighed against the risks of moving the patient.
IMRT and RapidArc commissioning of a TrueBeam linear accelerator using TG-119 protocol cases.
Wen, Ning; Zhao, Bo; Kim, Jinkoo; Chin-Snyder, Karen; Bellon, Maria; Glide-Hurst, Carri; Barton, Kenneth; Chen, Daiquan; Chetty, Indrin J
2014-09-08
The purpose of this study is to evaluate the overall accuracy of intensity-modulated radiation therapy (IMRT) and RapidArc delivery using both flattening filter (FF) and flattening filter-free (FFF) modalities based on test cases developed by AAPM Task Group 119. Institutional confidence limits (CLs) were established as the baseline for patient specific treatment plan quality assurance (QA). The effects of gantry range, gantry speed, leaf speed, dose rate, as well as the capability to capture intentional errors, were evaluated by measuring a series of Picket Fence (PF) tests using the electronic portal imaging device (EPID) and EBT3 films. Both IMRT and RapidArc plans were created in a Solid Water phantom (30 × 30 × 15 cm3) for the TG-119 test cases representative of normal clinical treatment sites for all five photon energies (6X, 10X, 15X, 6X-FFF, 10X-FFF) and the Exact IGRT couch was included in the dose calculation. One high-dose point in the PTV and one low-dose point in the avoidance structure were measured with an ion chamber in each case for each energy. Similarly, two GAFCHROMIC EBT3 films were placed in the coronal planes to measure planar dose distributions in both high- and low-dose regions. The confidence limit was set to have 95% of the measured data fall within the tolerance. The mean of the absolute dose deviation for variable dose rate and gantry speed during RapidArc delivery was within 0.5% for all energies. The corresponding results for leaf speed tests were all within 0.4%. The combinations of dynamic leaf gap (DLG) and MLC transmission factor were optimized based on the ion chamber measurement results of RapidArc delivery for each energy. The average 95% CLs for the high-dose point in the PTV were 0.030 ± 0.007 (range, 0.022-0.038) for the IMRT plans and 0.029 ± 0.011 (range, 0.016-0.043) for the RapidArc plans. For low-point dose in the avoidance structures, the CLs were 0.029 ± 0.006 (range, 0.024-0.039) for the IMRT plans and 0.027 ± 0.013 (range, 0.017-0.047) for the RapidArc plans. The average 95% CLs using 3%/3 mm gamma criteria in the high-dose region were 5.9 ± 2.7 (range, 1.4-8.6) and 3.9 ± 2.9 (range, 1.5-8.8) for IMRT and RapidArc plans, respectively. The average 95% CLs in the low-dose region were 5.3 ± 2.6 (range, 1.2-7.4) and 3.7 ± 2.8 (range, 1.8-8.3) for IMRT and RapidArc plans, respectively. Based on ion chamber, as well as film measurements, we have established CLs values to ensure the high precision of IMRT and RapidArc delivery for both FF and FFF modalities.
What is "theory of mind"? Concepts, cognitive processes and individual differences.
Apperly, Ian A
2012-01-01
Research on "theory of mind" has traditionally focused on a narrow participant group (preschool children) using a narrow range of experimental tasks (most notably, false-belief tasks). Recent work has greatly expanded the age range of human participants tested to include human infants, older children, and adults, has devised new tasks, and has adopted methods from cognitive psychology and neuroscience. However, theoretical work has not kept pace with these changes, with the result that studies using one kind of method or participant group often inherit assumptions about the nature of theory of mind from other research, with little regard for whether these assumptions are appropriate. I argue that three distinct approaches to thinking about theory of mind are already implicit in research practice, and that future work, whether with infants, children, or adults, will benefit from articulating these approaches more clearly and following their different implications for what theory of mind is and how it should be studied.
High Amplitude Acoustic Behavior of a Slit-Orifice Backed by a Cavity
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Gaeta, R. J., Jr.; DAgostino, M.; Jones, Mike (Technical Monitor)
2000-01-01
The objective of the study reported here was to acquire detailed acoustic data and limited and flow visualization data for numerical validation a new model of sound absorption by a very narrow rectangular slit backed by a cavity. The sound absorption model is being developed by Dr. C. K. W. Tam of Florida State University. This report documents normal incidence impedance measurements of a singular rectangular slit orifice with no mean flow. All impedance measurements are made within a 1.12 inch (28.5 mm) diameter impedance tube using the two-microphone method for several frequencies in the range 1000-6000Hz and incident sound pressure levels in the range 130 - 150 dB. In the interest of leaving the analysis of the data to the developers of more advanced analytical and computational models of sound absorption by narrow slits, we have refrained from giving our own explanations of the observed results, although many of the observed results can be explained using the classical explanations of sound absorption by orifices.
High Amplitude Acoustic Behavior of a Slit-Orifice Backed by a Cavity
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Gaeta, R. J., Jr.; DAgostino, M.
2000-01-01
The objective of this study was to acquire detailed acoustic data and limited flow visualization data for numerical validation of a new model of sound absorption by a very narrow rectangular slit backed by a cavity. The sound absorption model is that being developed by Dr. C. K. W. Tam of Florida State University. This report documents normal incidence impedance measurements of a singular rectangular slit orifice with no mean flow. All impedance measurements are made within a 1.12 inch (28.5 mm) diameter impedance tube using the two-microphone method for several frequencies in the range 1000 - 6000Hz and incident sound pressure levels in the range 130 - 150 dB. In the interest of leaving the analysis of the data to the developers of more advanced Analytical and computational models of sound absorption by narrow slits, we authors have refrained from giving our own explanations of the observed results, although many of the observed results can be explained using the classical understanding of sound absorption by orifices.
Optical polarimetry of Comet NEAT C/2001 Q4
NASA Astrophysics Data System (ADS)
Ganesh, S.; Joshi, U. C.; Baliyan, K. S.
2009-06-01
Comet NEAT C/2001 Q4 was observed for linear polarization using the optical polarimeter mounted at the 1.2 m telescope at Mt. Abu Observatory, during the months of May and June 2004. Observations were conducted through the International Halley Watch narrow band (continuum) and BVR broad band filters. During the observing run the phase angle ranged from 85.6° in May to 55° in June. As expected, polarization increases with wavelength in this phase angle range. Polarization colour in the narrow bands changes at different epochs, perhaps related to cometary activity or molecular emission contamination. The polarization was also measured in the cometary coma at different locations along a line, in the direction of the tail. As expected, we notice minor decrease in the polarization as photocenter (nucleus) is traversed while brightness decreases sharply away from it. Based on these polarization observations we infer that the Comet NEAT C/2001 Q4 has high polarization and a typical grain composition—mixture of silicates and organics.
Radosinski, Lukasz; Labus, Karolina
2017-10-05
Polyvinyl alcohol (PVA) is a material with a variety of applications in separation, biotechnology, and biomedicine. Using combined Monte Carlo and molecular dynamics techniques, we present an extensive comparative study of second- and third-generation force fields Universal, COMPASS, COMPASS II, PCFF, and the newly developed INTERFACE, as applied to this system. In particular, we show that an INTERFACE force field provides a possibility of composing a reliable atomistic model to reproduce density change of PVA matrix in a narrow temperature range (298-348 K) and calculate a thermal expansion coefficient with reasonable accuracy. Thus, the INTERFACE force field may be used to predict mechanical properties of the PVA system, being a scaffold for hydrogels, with much greater accuracy than latter approaches. Graphical abstract Molecular Dynamics and Monte Carlo studies indicate that it is possible to predict properties of the PVA in narrow temperature range by using the INTERFACE force field.
Peng, Peng; Li, Xinzhong; Li, Jiangong; Su, Yanqing; Guo, Jingjie
2016-01-01
An oscillatory microstructure has been observed during deep-cellular growth of directionally solidified Sn–36at.%Ni hyperperitectic alloy containing intermetallic compounds with narrow solubility range. This oscillatory microstructure with a dimension of tens of micrometers has been observed for the first time. The morphology of this wave-like oscillatory structure is similar to secondary dendrite arms, and can be observed only in some local positions of the sample. Through analysis such as successive sectioning of the sample, it can be concluded that this oscillatory microstructure is caused by oscillatory convection of the mushy zone during solidification. And the influence of convection on this oscillatory microstructure was characterized through comparison between experimental and calculations results on the wavelength. Besides, the change in morphology of this oscillatory microstructure has been proved to be caused by peritectic transformation during solidification. Furthermore, the melt concentration increases continuously during solidification of intermetallic compounds with narrow solubility range, which helps formation of this oscillatory microstructure. PMID:27066761
Peng, Peng; Li, Xinzhong; Li, Jiangong; Su, Yanqing; Guo, Jingjie
2016-04-12
An oscillatory microstructure has been observed during deep-cellular growth of directionally solidified Sn-36at.%Ni hyperperitectic alloy containing intermetallic compounds with narrow solubility range. This oscillatory microstructure with a dimension of tens of micrometers has been observed for the first time. The morphology of this wave-like oscillatory structure is similar to secondary dendrite arms, and can be observed only in some local positions of the sample. Through analysis such as successive sectioning of the sample, it can be concluded that this oscillatory microstructure is caused by oscillatory convection of the mushy zone during solidification. And the influence of convection on this oscillatory microstructure was characterized through comparison between experimental and calculations results on the wavelength. Besides, the change in morphology of this oscillatory microstructure has been proved to be caused by peritectic transformation during solidification. Furthermore, the melt concentration increases continuously during solidification of intermetallic compounds with narrow solubility range, which helps formation of this oscillatory microstructure.
Performance analysis of higher mode spoof surface plasmon polariton for terahertz sensing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yao, Haizi; Tu, Wanli; Zhong, Shuncong, E-mail: zhongshuncong@hotmail.com
2015-04-07
We investigated the spoof surface plasmon polaritons (SSPPs) on 1D grooved metal surface for terahertz sensing of refractive index of the filling analyte through a prism-coupling attenuated total reflection setup. From the dispersion relation analysis and the finite element method-based simulation, we revealed that the dispersion curve of SSPP got suppressed as the filling refractive index increased, which cause the coupling resonance frequency redshifting in the reflection spectrum. The simulated results for testing various refractive indexes demonstrated that the incident angle of terahertz radiation has a great effect on the performance of sensing. Smaller incident angle will result in amore » higher sensitive sensing with a narrower detection range. In the meanwhile, the higher order mode SSPP-based sensing has a higher sensitivity with a narrower detection range. The maximum sensitivity is 2.57 THz/RIU for the second-order mode sensing at 45° internal incident angle. The proposed SSPP-based method has great potential for high sensitive terahertz sensing.« less
Hua, Xia
2016-07-27
Being invoked as one of the candidate mechanisms for the latitudinal patterns in biodiversity, Janzen's hypothesis states that the limited seasonal temperature variation in the tropics generates greater temperature stratification across elevations, which makes tropical species adapted to narrower ranges of temperatures and have lower effective dispersal across elevations than species in temperate regions. Numerous empirical studies have documented latitudinal patterns in species elevational ranges and thermal niche breadths that are consistent with the hypothesis, but the theoretical underpinnings remain unclear. This study presents the first mathematical model to examine the evolutionary processes that could back up Janzen's hypothesis and assess the effectiveness of limited seasonal temperature variation to promote speciation along elevation in the tropics. Results suggest that trade-offs in thermal tolerances provide a mechanism for Janzen's hypothesis. Limited seasonal temperature variation promotes gradient speciation not due to the reduction in gene flow that is associated with narrow thermal niche, but due to the pleiotropic effects of more stable divergent selection of thermal tolerance on the evolution of reproductive incompatibility. The proposed modelling approach also provides a potential way to test a speciation model against genetic data. © 2016 The Author(s).
SU-E-T-75: A Simple Technique for Proton Beam Range Verification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burgdorf, B; Kassaee, A; Garver, E
2015-06-15
Purpose: To develop a measurement-based technique to verify the range of proton beams for quality assurance (QA). Methods: We developed a simple technique to verify the proton beam range with in-house fabricated devices. Two separate devices were fabricated; a clear acrylic rectangular cuboid and a solid polyvinyl chloride (PVC) step wedge. For efficiency in our clinic, we used the rectangular cuboid for double scattering (DS) beams and the step wedge for pencil beam scanning (PBS) beams. These devices were added to our QA phantom to measure dose points along the distal fall-off region (between 80% and 20%) in addition tomore » dose at mid-SOBP (spread out Bragg peak) using a two-dimensional parallel plate chamber array (MatriXX™, IBA Dosimetry, Schwarzenbruck, Germany). This method relies on the fact that the slope of the distal fall-off is linear and does not vary with small changes in energy. Using a multi-layer ionization chamber (Zebra™, IBA Dosimetry), percent depth dose (PDD) curves were measured for our standard daily QA beams. The range (energy) for each beam was then varied (i.e. ±2mm and ±5mm) and additional PDD curves were measured. The distal fall-off of all PDD curves was fit to a linear equation. The distal fall-off measured dose for a particular beam was used in our linear equation to determine the beam range. Results: The linear fit of the fall-off region for the PDD curves, when varying the range by a few millimeters for a specific QA beam, yielded identical slopes. The calculated range based on measured point dose(s) in the fall-off region using the slope resulted in agreement of ±1mm of the expected beam range. Conclusion: We developed a simple technique for accurately verifying the beam range for proton therapy QA programs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Young-Hoon; Department of Neurosurgery, Seoul National University College of Medicine, Seoul; Kim, Dong Gyu, E-mail: gknife@plaza.snu.ac.kr
2012-11-01
Purpose: This study was performed to assess the radiosurgical results of meningiomas extending into the internal acoustic canal (para-IAC meningiomas), with a particular focus on the effect of radiation dose to the cochlea on hearing outcome. Methods and Materials: A total of 50 patients who underwent radiosurgery for para-IAC meningiomas between 1998 and 2009, which were followed for 2 years, were enrolled. The mean age was 55.8 years (range, 15-75). The mean tumor volume was 6.1 cm{sup 3} (range, 1.0-19.0), the mean tumor length in the IAC was 6.9 mm (range, 1.3-13.3), and the mean prescribed marginal dose was 13.1more » Gy (range, 10-15) at an isodose line of 50%. The mean follow-up duration was 46 months (range, 24-122). Results: Eight (16.0%) patients had nonserviceable hearing at the time of surgery. At the last follow-up, the tumor control rate was 94%; unchanged in 17 patients, decreased in 30 patients, and increased in 3 patients. Among 42 patients with serviceable hearing at the time of radiosurgery, it was preserved in 41 (97.6%) patients at the last follow-up. The maximal and mean radiation doses to the cochleae of these 41 patients were 5.8 Gy {+-} 0.3 (range, 3.1-11.5) and 4.3 Gy {+-} 0.2 (range, 2.2-7.5), respectively. The maximal dose to the cochlea of the patient who lost hearing after radiosurgery was 4.7 Gy. Conclusions: The radiation dose to the cochlea may have the minimal toxic effect on the hearing outcome in patients who undergo radiosurgery for para-IAC meningiomas.« less
Extended range radiation dose-rate monitor
Valentine, Kenneth H.
1988-01-01
An extended range dose-rate monitor is provided which utilizes the pulse pileup phenomenon that occurs in conventional counting systems to alter the dynamic response of the system to extend the dose-rate counting range. The current pulses from a solid-state detector generated by radiation events are amplified and shaped prior to applying the pulses to the input of a comparator. The comparator generates one logic pulse for each input pulse which exceeds the comparator reference threshold. These pulses are integrated and applied to a meter calibrated to indicate the measured dose-rate in response to the integrator output. A portion of the output signal from the integrator is fed back to vary the comparator reference threshold in proportion to the output count rate to extend the sensitive dynamic detection range by delaying the asymptotic approach of the integrator output toward full scale as measured by the meter.
Dosimetry study of diagnostic X-ray using doped iodide normoxic polymer gels
NASA Astrophysics Data System (ADS)
Huang, Y. R.; Chang, Y. J.; Hsieh, L. L.; Liu, M. H.; Liu, J. S.; Chu, C. H.; Hsieh, B. T.
2014-11-01
In radiotherapy, polymer gel dosimeters are used for three-dimensional (3D) dose distribution. However, the doses are within the Gy range. In this study, we attempted to develop a low-dose 3D dosimeter within the mGy range for diagnostic radiology. The effect of the iodinated compound was used as a dose enhancement sensitizer to enhance the dose sensitivity of normoxic polymer gel dosimeters. This study aims to use N-isopropylacrylamide(NIPAM)-based and methacrylic acid (MAGAT)-based gels to evaluate the potential dose enhancement sensitizer, as well as to compare two gels that may be suitable for measuring diagnostic radiation doses. The suitable formulation of NIPAM gel [5% (w/w) gelatin, 5% (w/w) NIPAM, 3% (w/w) N,N‧-methylenebisacrylamide (BIS), 5 mM tetrakis (hydroxymethyl) phosphonium chloride (THPC), and 87% (w/w) deionized distilled water] and MAGAT gel (4% MAA, 9% gelatin, 87% deionized water, and 10 mM THPC) were used and loaded with clinical iodinated contrast medium agent (Iobitridol, Xenetix® 350). Irradiation was conducted using X-ray computed tomography. The irradiation doses ranged from 0 mGy to 80 mGy. Optical computed tomography was the employed gel measurement system. The results indicate that the iodinated contrast agent yields a quantifiable dose enhancement ratio. The dose enhancement ratios of NIPAM and MAGAT gels are 3.35±0.6 and 1.36±0.3, respectively. The developed NIPAM gel in this study could be suitable for measuring diagnostic radiation doses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baly, L.; Otazo, M. R.; Molina, D.
2006-09-08
A study of the phototransference of charges from deep to dosimetric traps in GR-200 material is presented and its convenience for dose re-estimation in the dose range between 2 and 100mSv is also analyzed. The recovering coefficient (RC) defined as the ratio between the phototransferred thermoluminescence (PTTL) and the original thermoluminescence (TL) of the dosimetric trap was used to evaluate the ratio of phototransferred charges from deep traps and the original charges in the dosimetric traps. The results show the convenience of this method for dose re-estimation for this material in the selected range of doses.
Flat Ge-doped optical fibres for food irradiation dosimetry
NASA Astrophysics Data System (ADS)
Noor, N. Mohd; Jusoh, M. A.; Razis, A. F. Abdull; Alawiah, A.; Bradley, D. A.
2015-04-01
Exposing food to radiation can improve hygiene quality, germination control, retard sprouting, and enhance physical attributes of the food product. To provide for food safety, radiation dosimetry in irradiated food is required. Herein, fabricated germanium doped (Ge-doped) optical fibres have been used. The fibres have been irradiated using a gamma source irradiator, doses in the range 1 kGy to 10 kGy being delivered. Using Ge-doped optical fibres of variable size, type and dopant concentration, study has been made of linearity, reproducibility, and fading. The thermoluminescence (TL) yield of the fibres were obtained and compared. The fibres exhibit a linear dose response over the investigated range of doses, with mean reproducibility to within 2.69 % to 8.77 %, exceeding the dose range of all commercial dosimeters used in evaluating high doses for the food irradiation industry. TL fading of the Ge-doped flat fibres has been found to be < 13%.
Components of Individual Differences in Human Intelligence.
1983-02-01
York: Macmillan, 1978. Craik , F. I. M. & Lockhart , R. S. Levels of processing : A framework for memory research. Journal of Verbal Learning and Verbal...what might be referred to as the " level of processing " to which they seek to ascribe the antecedents of intelligent performance, with levels ranging...in terns of processes operating at just a single level (or narrow range of levels , since levels are best conceived of as continuous), most theorists
Startup and mode competition in a 420 GHz gyrotron
NASA Astrophysics Data System (ADS)
Qixiang Zhao, A.; Sheng Yu, B.; Tianzhong Zhang, C.
2017-09-01
In the experiments of a 420 GHz second-harmonic gyrotron, it is found that the electron beam voltage and current ranges for single mode operation of TE17.4 are slightly narrower than those in the simulation. To explain this phenomenon, the startup scenario has been investigated with special emphasis on mode competition. The calculations indicate that the decreases of the operating ranges are caused by the voltage overshoot in the startup scenario.
EPR TOOTH DOSIMETRY OF SNTS AREA INHABITANTS.
Sholom, Sergey; Desrosiers, Marc; Bouville, André; Luckyanov, Nicholas; Chumak, Vadim; Simon, Steven L
2007-07-01
The determination of external dose to teeth of inhabitants of settlements near the Semipalatinsk Nuclear Test Site (SNTS) was conducted using the EPR dosimetry technique to assess radiation doses associated with exposure to radioactive fallout from the test site. In this study, tooth doses have been reconstructed for 103 persons with all studied teeth having been formed before the first nuclear test in 1949. Doses above those received from natural background radiation, termed "accident doses", were found to lie in the range from zero to approximately 2 Gy, with one exception, a dose for one person from Semipalatinsk city was approximately 9 Gy. The variability of reconstructed doses within each of the settlements demonstrated heterogeneity of the deposited fallout as well as variations in lifestyle. The village mean external gamma doses for residents of nine[ settlements were in the range from a few tens of mGy to approximately 100 mGy.
Lim, Mi-sun; Seong, Sook Jin; Park, Jeonghyeon; Seo, Jeong Ju; Lee, Joomi; Yu, Kyung-Sang; Lee, Hae Won; Yoon, Young-Ran
2012-04-01
Levofloxacin and cyclosporine show different pharmacokinetic properties, but are known to be dose proportional within the therapeutic range. The authors evaluated the pharmacokinetic proportionality of levofloxacin and cyclosporine over a 100-fold dose range in healthy human volunteers, by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Two independent, randomized, crossover studies were performed. For levofloxacin, eight volunteers were randomly assigned in a 1:1 ratio to receive a low dose (7.5 mg) orally or intravenously, followed by a 1-week washout period and administration via the alternate route. After another 1-week washout period, a therapeutic dose (750 mg) was administered to all eight subjects. For cyclosporine, another eight volunteers received a low dose (2 mg) or a therapeutic dose (200 mg) orally with a 1-week washout period. Drug concentrations were determined by LC-MS/MS. For levofloxacin, the mean values for dose-normalized C(max) and AUC(last) with the two doses were as follows: therapeutic dose, 15.2 ± 4.6 ng/ml/mg and 103.6 ± 15.5 ng·h/ml/mg, respectively; low dose, 17.1 ± 6.5 ng/ml/mg and 72.6 ± 8.7 ng·h/ml/mg, respectively. For cyclosporine, the mean values for dose-normalized C(max) and AUC(last) were as follows: therapeutic dose, 4.9 ± 1.5 ng/ml/mg and 15.4 ± 4.9 ng·h/ml/mg, respectively; low dose, 1.6 ± 0.6 ng/ml/mg and 9.3 ± 7.3 ng·h/ml/mg, respectively. In this study levofloxacin, which is completely absorbed and primarily eliminated renally without modification, showed better pharmacokinetic proportionality than cyclosporine, which is poorly absorbed and extensively metabolized.
Schultze-Mosgau, Marcus-Hillert; Schuett, Barbara; Hafner, Frank-Thorsten; Zollmann, Frank; Kaiser, Andreas; Hoechel, Joachim; Rohde, Beate
2017-01-01
Vilaprisan is a novel, potent, and highly selective progesterone receptor modulator, which might offer a promising option for the treatment of uterine fibroids. In this randomized, placebo-controlled, parallel-group phase 1 study, the pharmacokinetics and safety of vilaprisan were investigated in healthy postmenopausal women. Subjects received a single oral dose of vilaprisan (1, 5, 15, or 30 mg) or placebo and - after a wash-out period - daily doses of the same strength over 28 days. Safety assessments included vital signs, ECGs, clinical laboratory tests, and adverse events. Blood samples for pharmacokinetic (PK) profiles were collected over 14 days after single dose (sd) and multiple dose (md; day 28). Vilaprisan was well tolerated. Mild to moderate adverse events occurred with similar frequency at all dose levels. Following single dose, maximum vilaprisan concentrations were observed 1 - 2 hours post-dose. Terminal half-lives ranged from 31 to 38 hours. Maximum concentrations of vilaprisan (Cmax) and exposure to vilaprisan (AUC) increased roughly dose-proportionally from 3.74 µg/L (1 mg) to 68.6 µg/L (30 mg) and 58.5 µg×h/L to 1,590 µg×h/L, respectively. With daily dosing, accumulation consistent with the long terminal half-life was observed (AUC(0-24)md/AUC(0-24)sd ratios: 1.9 to 3.2). The ratio AUC(0-24)md/AUCsd increased with dose from ~ 1 (1 mg) to 1.5 (30 mg). Exposure to vilaprisan increased roughly dose-proportionally in the dose range studied and accumulated after multiple dosing as expected based on t1/2, indicating linear pharmacokinetics of vilaprisan in the expected therapeutic dose range. .
Sky-radiance gradient measurements at narrow bands in the visible.
Winter, E M; Metcalf, T W; Stotts, L B
1995-07-01
Accurate calibrated measurements of the radiance of the daytime sky were made in narrow bands in the visible portion of the spectrum. These measurements were made over several months and were tabulated in a sun-referenced coordinate system. The radiance as a function of wavelength at angles ranging from 5 to 90 deg was plotted. A best-fit inverse power-law fit shows inversely linear behavior of the radiance versus wavelength near the Sun (5 deg) and a slope approaching inverse fourth power far from the Sun (60 deg). This behavior fits a Mie-scattering interpretation near the Sun and a Rayleigh-scattering interpretation away from the Sun. The results are also compared with LOWTRAN models.
Narrow-band tunable terahertz emission from ferrimagnetic Mn{sub 3-x}Ga thin films
DOE Office of Scientific and Technical Information (OSTI.GOV)
Awari, N.; University of Groningen, 9747 AG Groningen; Kovalev, S., E-mail: s.kovalev@hzdr.de, E-mail: c.fowley@hzdr.de, E-mail: rodek@tcd.ie
2016-07-18
Narrow-band terahertz emission from coherently excited spin precession in metallic ferrimagnetic Mn{sub 3-x}Ga Heusler alloy nanofilms has been observed. The efficiency of the emission, per nanometer film thickness, is comparable or higher than that of classical laser-driven terahertz sources based on optical rectification. The center frequency of the emission from the films can be tuned precisely via the film composition in the range of 0.20–0.35 THz, making this type of metallic film a candidate for efficient on-chip terahertz emitters. Terahertz emission spectroscopy is furthermore shown to be a sensitive probe of magnetic properties of ultra-thin films.
Magnetic agglomeration method for size control in the synthesis of magnetic nanoparticles
Huber, Dale L [Albuquerque, NM
2011-07-05
A method for controlling the size of chemically synthesized magnetic nanoparticles that employs magnetic interaction between particles to control particle size and does not rely on conventional kinetic control of the reaction to control particle size. The particles are caused to reversibly agglomerate and precipitate from solution; the size at which this occurs can be well controlled to provide a very narrow particle size distribution. The size of particles is controllable by the size of the surfactant employed in the process; controlling the size of the surfactant allows magnetic control of the agglomeration and precipitation processes. Agglomeration is used to effectively stop particle growth to provide a very narrow range of particle sizes.
The influence of temperature on narrow I 1 and I 2 lines in the luminescence spectrum of Ni0.6Zn0.4O
NASA Astrophysics Data System (ADS)
Sokolov, V. I.; Pustovarov, V. A.; Ivanov, V. Yu.; Gruzdev, N. B.; Sokolov, P. S.; Baranov, A. N.
2014-05-01
The behavior of the luminescence spectrum of solid solution Ni0.6Zn0.4O, in which two intense narrow lines were recently discovered, is investigated as a function of temperature. It is shown that the intensity of one of the lines drops in accordance with the Mott law with increasing temperature in the range between 10 and 50 K. The lines experience broadening, and the ratio of their intensities changes. In addition, the lines shift toward lower energies. This shift and broadening of both lines occur differently, suggesting that they are of different nature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, X; Kantor, M; Zhu, X
2014-06-01
Purpose: To evaluate the dosimetric accuracy for proton therapy patients with metal implants in CT using metal deletion technique (MDT) artifacts reduction. Methods: Proton dose accuracies under CT metal artifacts were first evaluated using a water phantom with cylindrical inserts of different materials (titanium and steel). Ranges and dose profiles along different beam angles were calculated using treatment planning system (Eclipse version 8.9) on uncorrected CT, MDT CT, and manually-corrected CT, where true Hounsfield units (water) were assigned to the streak artifacts. In patient studies, the treatment plans were developed on manually-corrected CTs, then recalculated on MDT and uncorrected CTs.more » DVH indices were compared between the dose distributions on all the CTs. Results: For water phantom study with 1/2 inch titanium insert, the proton range differences estimated by MDT CT were with 1% for all beam angles, while the range error can be up to 2.6% for uncorrected CT. For the study with 1 inch stainless steel insert, the maximum range error calculated by MDT CT was 1.09% among all the beam angles compared with maximum range error with 4.7% for uncorrected CT. The dose profiles calculated on MDT CTs for both titanium and steel inserts showed very good agreements with the ones calculated on manually-corrected CTs, while large dose discrepancies calculated using uncorrected CTs were observed in the distal end region of the proton beam. The patient study showed similar dose distribution and DVHs for organs near the metal artifacts recalculated on MDT CT compared with the ones calculated on manually-corrected CT, while the differences between uncorrected and corrected CTs were much pronounced. Conclusion: In proton therapy, large dose error could occur due to metal artifact. The MDT CT can be used for proton dose calculation to achieve similar dose accuracy as the current clinical practice using manual correction.« less
Howell, Rebecca M; Burgett, Eric A; Isaacs, Daniel; Price Hedrick, Samantha G; Reilly, Michael P; Rankine, Leith J; Grantham, Kevin K; Perkins, Stephanie; Klein, Eric E
2016-05-01
To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth-dose data to in-air H* (10) values. For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10(6) to 1.04 × 10(7) n/cm(2)/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy. For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.