Sample records for narrow qrs heart

  1. Association of intraventricular mechanical dyssynchrony with response to cardiac resynchronization therapy in heart failure patients with a narrow QRS complex

    PubMed Central

    van Bommel, Rutger J.; Tanaka, Hidekazu; Delgado, Victoria; Bertini, Matteo; Borleffs, Carel Jan Willem; Ajmone Marsan, Nina; Holzmeister, Johannes; Ruschitzka, Frank; Schalij, Martin J.; Bax, Jeroen J.; Gorcsan, John

    2010-01-01

    Aims Current criteria for cardiac resynchronization therapy (CRT) are restricted to patients with a wide QRS complex (>120 ms). Overall, only 30% of heart failure patients demonstrate a wide QRS complex, leaving the majority of heart failure patients without this treatment option. However, patients with a narrow QRS complex exhibit left ventricular (LV) mechanical dyssynchrony, as assessed with echocardiography. To further elucidate the possible beneficial effect of CRT in heart failure patients with a narrow QRS complex, this two-centre, non-randomized observational study focused on different echocardiographic parameters of LV mechanical dyssynchrony reflecting atrioventricular, interventricular and intraventricular dyssynchrony, and the response to CRT in these patients. Methods and results A total of 123 consecutive heart failure patients with a narrow QRS complex (<120 ms) undergoing CRT was included at two centres. Several widely accepted measures of mechanical dyssynchrony were evaluated: LV filling ratio (LVFT/RR), LV pre-ejection time (LPEI), interventricular mechanical dyssynchrony (IVMD), opposing wall delay (OWD), and anteroseptal posterior wall delay with speckle tracking (ASPWD). Response to CRT was defined as a reduction ≥15% in left ventricular end-systolic volume at 6 months follow-up. Measures of dyssynchrony can frequently be observed in patients with a narrow QRS complex. Nonetheless, for LVFT/RR, LPEI, and IVMD, presence of predefined significant dyssynchrony is <20%. Significant intraventricular dyssynchrony is more widely observed in these patients. With receiver operator characteristic curve analyses, both OWD and ASPWD demonstrated usefulness in predicting response to CRT in narrow QRS patients with a cut-off value of 75 and 107 ms, respectively. Conclusion Mechanical dyssynchrony can be widely observed in heart failure patients with a narrow QRS complex. In particular, intraventricular measures of mechanical dyssynchrony may be useful in

  2. Cardiac-resynchronization therapy in heart failure with a narrow QRS complex.

    PubMed

    Ruschitzka, Frank; Abraham, William T; Singh, Jagmeet P; Bax, Jeroen J; Borer, Jeffrey S; Brugada, Josep; Dickstein, Kenneth; Ford, Ian; Gorcsan, John; Gras, Daniel; Krum, Henry; Sogaard, Peter; Holzmeister, Johannes

    2013-10-10

    Cardiac-resynchronization therapy (CRT) reduces morbidity and mortality in chronic systolic heart failure with a wide QRS complex. Mechanical dyssynchrony also occurs in patients with a narrow QRS complex, which suggests the potential usefulness of CRT in such patients. We conducted a randomized trial involving 115 centers to evaluate the effect of CRT in patients with New York Heart Association class III or IV heart failure, a left ventricular ejection fraction of 35% or less, a QRS duration of less than 130 msec, and echocardiographic evidence of left ventricular dyssynchrony. All patients underwent device implantation and were randomly assigned to have CRT capability turned on or off. The primary efficacy outcome was the composite of death from any cause or first hospitalization for worsening heart failure. On March 13, 2013, the study was stopped for futility on the recommendation of the data and safety monitoring board. At study closure, the 809 patients who had undergone randomization had been followed for a mean of 19.4 months. The primary outcome occurred in 116 of 404 patients in the CRT group, as compared with 102 of 405 in the control group (28.7% vs. 25.2%; hazard ratio, 1.20; 95% confidence interval [CI], 0.92 to 1.57; P=0.15). There were 45 deaths in the CRT group and 26 in the control group (11.1% vs. 6.4%; hazard ratio, 1.81; 95% CI, 1.11 to 2.93; P=0.02). In patients with systolic heart failure and a QRS duration of less than 130 msec, CRT does not reduce the rate of death or hospitalization for heart failure and may increase mortality. (Funded by Biotronik and GE Healthcare; EchoCRT ClinicalTrials.gov number, NCT00683696.).

  3. Reduced long-term overall mortality in heart failure patients with prolonged QRS treated with CRT combined with ICD vs. heart failure patients with narrow QRS treated with ICD only.

    PubMed

    Palmisano, Pietro; Accogli, Michele; Pisanò, Ennio Carmine Luigi; Zaccaria, Maria; De Blasi, Sergio; Ponzetta, Maria Antonietta; Valsecchi, Sergio; Milanese, Giovanni; Lauretti, Maurelio; Magliari, Francesco

    2016-09-01

    It is not known whether heart failure (HF) patients with prolonged QRS who undergo cardiac resynchronization therapy combined with a defibrillator (CRT-D) have a prognostic advantage over HF patients with narrow QRS (therefore without indication for CRT) treated with an implantable cardioverter defibrillator (ICD) only. The aim of this study was to compare the long-term mortality of a group of HF patients with prolonged QRS receiving CRT-D with that of a similar group of patients with narrow QRS receiving ICD only. A total of 312 patients (mean age 66 ± 13 years; 84% male, mean left ventricular ejection fraction 25 ± 4%, mean New York Heart Association class 2.6 ± 0.5) were included in the analysis. Of these, 138 with a QRS complex duration ≥120 ms received a CRT-D. During follow-up, the time and cause of death were assessed. During a median follow-up of 46 months, CRT-D patients showed significantly lower overall mortality (P = 0.038). Compared with patients receiving ICD only, CRT-D patients showed lower HF mortality (P = 0.003). Coronary mortality, non-cardiac mortality, and sudden mortality were similar in both groups (all P > 0.05). A positive response to CRT was an independent predictor of reduced mortality on multivariate analysis (hazard ratio: 0.27; P = 0.047). In HF patients treated with ICD, the subgroup of patients with prolonged QRS who receive CRT-D displays better long-term survival than narrow QRS ICD recipients, owing to their reduced HF mortality. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. Multipoint Pacing versus conventional ICD in Patients with a Narrow QRS complex (MPP Narrow QRS trial): study protocol for a pilot randomized controlled trial.

    PubMed

    Gasparini, Maurizio; Galimberti, Paola; Bragato, Renato; Ghio, Stefano; Raineri, Claudia; Landolina, Maurizio; Chieffo, Enrico; Lunati, Maurizio; Mulargia, Ederina; Proclemer, Alessandro; Facchin, Domenico; Rordorf, Roberto; Vicentini, Alessandro; Marcantoni, Lina; Zanon, Francesco; Klersy, Catherine

    2016-12-03

    Despite an intensive search for predictors of the response to cardiac resynchronization therapy (CRT), the QRS duration remains the simplest and most robust predictor of a positive response. QRS duration of ≥ 130 ms is considered to be a prerequisite for CRT; however, some studies have shown that CRT may also be effective in heart failure (HF) patients with a narrow QRS (<130 ms). Since CRT can now be performed by pacing the left ventricle from multiple vectors via a single quadripolar lead, it is possible that multipoint pacing (MPP) might be effective in HF patients with a narrow QRS. This article reports the design of the MPP Narrow QRS trial, a prospective, randomized, multicenter, controlled feasibility study to investigate the efficacy of MPP using two LV pacing vectors in patients with a narrow QRS complex (100-130 ms). Fifty patients with a standard ICD indication will be enrolled and randomized (1:1) to either an MPP group or a Standard ICD group. All patients will undergo a low-dose dobutamine stress echo test and only those with contractile reserve will be included in the study and randomized. The primary endpoint will be the percentage of patients in each group that have reverse remodeling at 12 months, defined as a reduction in left ventricular end-systolic volume (LVESV) of >15% from the baseline. This feasibility study will determine whether MPP improves reverse remodeling, as compared with standard ICD, in HF patients who have a narrow QRS complex (100-130 ms). ClinicalTrials.gov, NCT02402816 . Registered on 25 March 2015.

  5. A narrow QRS tachycardia and cannon A waves: What is the mechanism?

    PubMed

    Ali, Hussam; Epicoco, Gianluca; De Ambroggi, Guido; Lupo, Pierpaolo; Foresti, Sara; Cappato, Riccardo

    2017-07-01

    Regular narrow QRS tachycardia, particularly if well-tolerated, is usually considered a "benign" arrhythmia of a supraventricular origin. This case concerns an 82-year-old male with ischemic heart disease who presented with recurrent episodes of a narrow QRS tachycardia that was initially diagnosed and treated as atrial tachyarrhythmia. However, careful physical examination and ECG analysis established the correct diagnosis, and the patient was managed appropriately. Remarkably, the observation of irregular cannon A waves, and Lewis lead recording, confirmed atrioventricular dissociation during tachycardia and indicated its underlying mechanism. © 2016 Wiley Periodicals, Inc.

  6. Sudden cardiac death in adults with congenital heart disease: does QRS-complex fragmentation discriminate in structurally abnormal hearts?

    PubMed

    Vehmeijer, Jim T; Koyak, Zeliha; Bokma, Jouke P; Budts, Werner; Harris, Louise; Mulder, Barbara J M; de Groot, Joris R

    2018-06-01

    Sudden cardiac death (SCD) causes a large portion of all mortality in adult congenital heart disease (ACHD) patients. However, identification of high-risk patients remains challenging. Fragmented QRS-complexes (fQRS) are a marker for SCD in patients with acquired heart disease but data in ACHD patients are lacking. We therefore aim to evaluate the prognostic value of fQRS for SCD in ACHD patients. From a multicentre cohort of 25 790 ACHD patients, we included tachyarrhythmic SCD cases (n = 147), and controls (n = 266) matched by age, gender, congenital defect and (surgical) intervention. fQRS was defined as ≥1 discontinuous deflection in narrow QRS-complexes, and ≥2 in wide QRS-complexes (>120 ms), in two contiguous ECG leads. We calculated odds ratios (OR) using univariable and multivariable conditional logistic regression models correcting for impaired systemic ventricular function, heart failure and QRS duration >120 ms. ECGs of 147 SCD cases (65% male, median age of death 34 years) and of 266 controls were assessed. fQRS was present in 51% of cases and 34% of controls (OR 2.0, P = 0.003). In multivariable analysis, fQRS was independently associated with SCD (OR 1.9, P = 0.01). The most common diagnose of SCD cases was tetralogy of Fallot (ToF, 34 cases). In ToF, fQRS was present in 71% of cases vs. 43% of controls (OR for SCD 2.8, P = 0.03). fQRS was independently associated with SCD in ACHD patients in a cohort of SCD patients and matched controls. fQRS may therefore contribute to the decision when evaluating ACHD patients for primary prevention of SCD.

  7. Clinical and electrophysiological characteristics of patients with paroxysmal intra-His block with narrow QRS complexes.

    PubMed

    Ragupathi, Loheetha; Johnson, Drew; Greenspon, Arnold; Frisch, Daniel; Ho, Reginald T; Pavri, Behzad B

    2018-04-18

    Atrioventricular (AV) block is usually due to infranodal disease and associated with a wide QRS complex; such patients often progress to complete AV block and pacemaker dependency. Uncommonly, infranodal AV block can occur within the His bundle with a narrow QRS complex. The aims of this study were to define clinical/echocardiographic characteristics of patients with AV block within the His bundle and report progression to pacemaker dependency. We retrospectively identified patients with narrow QRS complexes and documented intra-His delay or block at electrophysiology study (group A) or with electrocardiogram-documented Mobitz II AV block/paroxysmal AV block (group B). Clinical, electrophysiological, and echocardiographic variables at presentation and pacemaker parameters at the last follow-up visit were evaluated. Twenty-seven patients (19 women) were identified (mean age 64 ± 13 years; range, 38-85 years). Four patients who had <1 month of follow-up were excluded. There were 12 patients in group A and 11 in group B; 21 of 23 presented with syncope/presyncope. All patients received pacemakers: 8 single chamber and 15 dual chamber. After a median follow-up of 6.4 years, the median percentage of ventricular pacing was 1% (interquartile range 0%-4.66%). One patient developed true pacemaker dependency. Aortic and/or mitral annular calcification was present in 13 of 22 patients with available echocardiograms. Patients who present with syncope and narrow QRS complexes with intra-His delay or Mobitz II paroxysmal AV block with narrow QRS complexes rarely progress to pacemaker dependency and require infrequent pacing. This entity is more common in women, with a higher prevalence of aortic and/or mitral annular calcification. If confirmed by additional studies, single-chamber pacemaker may be sufficient. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  8. Assessment of the relationship between a narrow fragmented QRS complex and coronary slow flow.

    PubMed

    Cakmak, Huseyin Altug; Aslan, Serkan; Gul, Mehmet; Kalkan, Ali Kemal; Ozturk, Derya; Celik, Omer; Tasbulak, Omer; Satilmisoglu, Muhammet Hulusi

    2015-01-01

    The coronary slow flow (CSF) phenomenon is a delayed antegrade progression of contrast agent to the distal branch of a coronary artery in the absence of obstructive coronary artery disease (CAD). A narrow fragmented QRS (fQRS) has been reported as a significant predictor of sudden cardiac death in patients with idiopathic dilated cardiomyopathy. The present study aimed to investigate the relationship between a narrow fQRS on the admission electrocardiogram (ECG) and CSF on coronary angiography. This study included 165 consecutive patients (112 CSF, 53 controls) who underwent first-time diagnostic conventional coronary angiography for suspected CAD. Coronary flow was quantified by thrombolysis in myocardial infarction (TIMI) frame count (TFC). The patients were divided into two groups according to the presence or absence of a narrow fQRS complex on the admission ECG. Forty four patients were in the fQRS group (mean age, 52.97 ± 3.13 years). There was no difference between the two groups with respect to age, gender, body mass index, family history, hyperlipidemia, hypertension, or diabetes mellitus. The extent of CSF was significantly greater in the fQRS group compared to the non-fragmented group (p < 0.001). A significant correlation was also found between mean TFC values and fQRS (p < 0.001). On multivariate analysis, only CSF (p = 0.03) was a significant independent predictor for narrow fQRS, after adjustment for other parameters. The narrow fQRS is a simple, inexpensive, and readily available noninvasive ECG parameter that may be a new potential indicator of myocardial damage in patients with CSF.

  9. Effect of study design on the reported effect of cardiac resynchronization therapy (CRT) on quantitative physiological measures: stratified meta-analysis in narrow-QRS heart failure and implications for planning future studies.

    PubMed

    Jabbour, Richard J; Shun-Shin, Matthew J; Finegold, Judith A; Afzal Sohaib, S M; Cook, Christopher; Nijjer, Sukhjinder S; Whinnett, Zachary I; Manisty, Charlotte H; Brugada, Josep; Francis, Darrel P

    2015-01-06

    Biventricular pacing (CRT) shows clear benefits in heart failure with wide QRS, but results in narrow QRS have appeared conflicting. We tested the hypothesis that study design might have influenced findings. We identified all reports of CRT-P/D therapy in subjects with narrow QRS reporting effects on continuous physiological variables. Twelve studies (2074 patients) met these criteria. Studies were stratified by presence of bias-resistance steps: the presence of a randomized control arm over a single arm, and blinded outcome measurement. Change in each endpoint was quantified using a standardized effect size (Cohen's d). We conducted separate meta-analyses for each variable in turn, stratified by trial quality. In non-randomized, non-blinded studies, the majority of variables (10 of 12, 83%) showed significant improvement, ranging from a standardized mean effect size of +1.57 (95%CI +0.43 to +2.7) for ejection fraction to +2.87 (+1.78 to +3.95) for NYHA class. In the randomized, non-blinded study, only 3 out of 6 variables (50%) showed improvement. For the randomized blinded studies, 0 out of 9 variables (0%) showed benefit, ranging from -0.04 (-0.31 to +0.22) for ejection fraction to -0.1 (-0.73 to +0.53) for 6-minute walk test. Differences in degrees of resistance to bias, rather than choice of endpoint, explain the variation between studies of CRT in narrow-QRS heart failure addressing physiological variables. When bias-resistance features are implemented, it becomes clear that these patients do not improve in any tested physiological variable. Guidance from studies without careful planning to resist bias may be far less useful than commonly perceived. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  10. The prognostic impact of dynamic ventricular dyssynchrony in patients with idiopathic dilated cardiomyopathy and narrow QRS.

    PubMed

    D'Andrea, Antonello; Mele, Donato; Nistri, Stefano; Riegler, Lucia; Galderisi, Maurizio; Agricola, Eustachio; Losi, Maria Angela; Ballo, Piercarlo; Mondillo, Sergio; Badano, Luigi P

    2013-02-01

    Asynchronous myocardial contraction adversely influences left ventricular (LV) function and is therefore associated with a poor prognosis in heart failure. Exercise-induced change in ventricular dyssynchrony may be an important determinant of dynamic changes in cardiac output and mitral regurgitation. A prospective, longitudinal study was designed with pre-defined dyssynchrony index and outcome variables to test the hypothesis that dynamic dyssynchrony is associated with worse long-term event-free survival in patients with dilated cardiomyopathy (DCM) and 'narrow' QRS complex. One-hundred eighty patients (62 ± 8 years; 110 males) with NYHA class II-III, idiopathic DCM, ejection fraction ≤35%, and QRS duration <120 ms were selected. All the patients underwent standard Doppler echo, colour tissue velocity imaging (DTI), and supine bicycle exercise stress echocardiography. Cardiac synchronicity was defined, at rest and at peak exercise, as DTI velocity opposing-wall delay (significant if ≥65 ms). Outcome was defined as freedom from death, heart transplantation, or LV-assist device implantation, over a median follow-up of 48 months, and a Cox proportional hazards model was used for survival analysis. At baseline examination, DCM patients showed a reduced LV ejection fraction (31 + 4%). A significant electromechanical delay in 58 patients (32%). At the peak of physical exercise, a significant electromechanical delay was detected in 103 patients (57%). There were 41 events during the follow-up (23%): 28 cardiac deaths, 8 heart transplantations, and 5 LV-assist device implantations over 4 years. When adjusted for confounding baseline variables, LV end-diastolic volume, restrictive mitral flow pattern, severity of mitral regurgitation, and the presence of exercise-induced intraventricular dyssynchrony were the only independent determinants of an adverse outcome. In patients with idiopathic DCM and narrow QRS, the increase in echocardiographic dyssynchrony during

  11. QRS peak detection for heart rate monitoring on Android smartphone

    NASA Astrophysics Data System (ADS)

    Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto

    2017-11-01

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.

  12. Improved symptoms, physical limitation, and self-efficacy after resynchronization in a patient with heart failure and a prolonged QRS duration.

    PubMed

    Conaway, Darcy G; Sullivan, Robbie; McCullough, Peter A

    2004-01-01

    This report examines the impact of resynchronization therapy in a patient with class IV heart failure and a prolonged QRS duration on electrocardiogram. The Kansas City Cardiomyopathy Questionnaire (KCCQ) was used to assess the patient's health status prior to, immediately after, and 2 months after placement of a biventricular pacemaker. B-type natriuretic peptide (BNP) values and electrocardiogram QRS duration were recorded to further document clinical status. Our patient experienced statistically significant improvements in 7 of 10 KCCQ domains after resynchronization. QRS duration narrowed following the procedure and BNP values decreased. Resynchronization therapy improved this patient's symptoms, physical limitations, and self-efficacy when maximal medical therapy failed.

  13. Distinctive Left Ventricular Activations Associated With ECG Pattern in Heart Failure Patients.

    PubMed

    Derval, Nicolas; Duchateau, Josselin; Mahida, Saagar; Eschalier, Romain; Sacher, Frederic; Lumens, Joost; Cochet, Hubert; Denis, Arnaud; Pillois, Xavier; Yamashita, Seigo; Komatsu, Yuki; Ploux, Sylvain; Amraoui, Sana; Zemmoura, Adlane; Ritter, Philippe; Hocini, Mélèze; Haissaguerre, Michel; Jaïs, Pierre; Bordachar, Pierre

    2017-06-01

    In contrast to patients with left bundle branch block (LBBB), heart failure patients with narrow QRS and nonspecific intraventricular conduction delay (NICD) display a relatively limited response to cardiac resynchronization therapy. We sought to compare left ventricular (LV) activation patterns in heart failure patients with narrow QRS and NICD to patients with LBBB using high-density electroanatomic activation maps. Fifty-two heart failure patients (narrow QRS [n=18], LBBB [n=11], NICD [n=23]) underwent 3-dimensional electroanatomic mapping with a high density of mapping points (387±349 LV). Adjunctive scar imaging was available in 37 (71%) patients and was analyzed in relation to activation maps. LBBB patients typically demonstrated (1) a single LV breakthrough at the septum (38±15 ms post-QRS onset); (2) prolonged right-to-left transseptal activation with absence of direct LV Purkinje activity; (3) homogeneous propagation within the LV cavity; and (4) latest activation at the basal lateral LV. In comparison, both NICD and narrow QRS patients demonstrated (1) multiple LV breakthroughs along the posterior or anterior fascicles: narrow QRS versus LBBB, 5±2 versus 1±1; P =0.0004; NICD versus LBBB, 4±2 versus 1±1; P =0.001); (2) evidence of early/pre-QRS LV electrograms with Purkinje potentials; (3) rapid propagation in narrow QRS patients and more heterogeneous propagation in NICD patients; and (4) presence of limited areas of late activation associated with LV scar with high interindividual heterogeneity. In contrast to LBBB patients, narrow QRS and NICD patients are characterized by distinct mechanisms of LV activation, which may predict poor response to cardiac resynchronization therapy. © 2017 American Heart Association, Inc.

  14. Systolic blood pressure but not electrocardiogram QRS duration is associated with heart rate variability (HRV): a cross-sectional study in rural Australian non-diabetics.

    PubMed

    Lee, Yvonne Yin Leng; Jelinek, Herbert F; McLachlan, Craig S

    2017-01-01

    A positive correlation between ECG derived QRS duration and heart rate variability (HRV) parameters had previously been reported in young healthy adults. We note this study used a narrow QRS duration range, and did not adjust for systolic blood pressure. Our aims are to investigate associations between systolic blood pressure (SBP), QRS duration and HRV in a rural aging population. A retrospective cross sectional population was obtained from the CSU Diabetes Screening Research Initiative data base where 200 participants had no diabetes or pre-diabetes. SBP data were matched with ECG derived QRS duration and HRV parameters. HRV parameters were calculated from R-R intervals. Resting 12-lead electrocardiograms were obtained from each subject using a Welch Allyn PC-Based ECG system. Pearson correlation analysis revealed no statistically significant associations between HRV parameters and QRS duration. No significant mean differences in HRV parameter subgroups across defined QRS cut-offs were found. SBP > 146 mmHg was associated with increasing QRS durations, however this association disappeared once models were adjusted for age and gender. SBP was also significantly associated with a number of HRV parameters using Pearson correlation analysis, including high frequency (HF) ( p  < 0.05), HFln ( p  < 0.02), RMSDD ( p  < 0.02) and non-linear parameters; ApEN ( p  < 0.001) were negatively correlated with increasing SBP while the low frequency to high frequency ratio (LF/HF) increased with increasing SBP ( p  < 0.03). Our results do not support associations between ECG derived R-R derived HRV parameters and QRS duration in aging populations. We suggest that ventricular conduction as determined by QRS duration is independent of variations in SA-node heart rate variability.

  15. Comparison of QRS Duration and Associated Cardiovascular Events in American Indian Men Versus Women (The Strong Heart Study).

    PubMed

    Deen, Jason F; Rhoades, Dorothy A; Noonan, Carolyn; Best, Lyle G; Okin, Peter M; Devereux, Richard B; Umans, Jason G

    2017-06-01

    Electrocardiographic QRS duration at rest is associated with sudden cardiac death and death from coronary heart disease in the general population. However, its relation to cardiovascular events in American Indians, a population with persistently high cardiovascular disease mortality, is unknown. The relation of QRS duration to incident cardiovascular disease during 17.2 years of follow-up was assessed in 1,851 male and female Strong Heart Study participants aged 45 to 74 years without known cardiovascular disease at baseline. Cox regression with robust standard error estimates was used to determine the association between quintiles of QRS duration and incident cardiovascular disease in gender-stratified analyses, adjusted for age, systolic blood pressure, hypertension, antihypertensive medication use, body mass index, current smoking, diabetes, total cholesterol, high-density lipoprotein cholesterol, and albuminuria. In women only, QRS duration in the highest quintile (≥105 ms) conferred significantly higher risk of cardiovascular disease than QRS duration in the lowest quintile (64 to 84 ms) (hazard ratio 1.6, 95% CI 1.1 to 2.4) likely because of higher risks of coronary heart disease (hazard ratio 1.8, 95% CI 1.1 to 3.1) and myocardial infarction (hazard ratio 2.1, 95% CI 1.0 to 4.7). Furthermore, when added to the Strong Heart Study Coronary Heart Disease Risk Calculator, QRS duration significantly improved prediction of future coronary heart disease events in women (Net Reclassification Index 0.17, 95% CI 0.06 to 0.47). In conclusion, QRS duration is an independent predictor of cardiovascular disease in women in the Strong Heart Study cohort and may have value in estimating risk in populations with similar risk profiles and a high lifetime incidence of cardiovascular disease. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Fetal QRS detection and heart rate estimation: a wavelet-based approach.

    PubMed

    Almeida, Rute; Gonçalves, Hernâni; Bernardes, João; Rocha, Ana Paula

    2014-08-01

    Fetal heart rate monitoring is used for pregnancy surveillance in obstetric units all over the world but in spite of recent advances in analysis methods, there are still inherent technical limitations that bound its contribution to the improvement of perinatal indicators. In this work, a previously published wavelet transform based QRS detector, validated over standard electrocardiogram (ECG) databases, is adapted to fetal QRS detection over abdominal fetal ECG. Maternal ECG waves were first located using the original detector and afterwards a version with parameters adapted for fetal physiology was applied to detect fetal QRS, excluding signal singularities associated with maternal heartbeats. Single lead (SL) based marks were combined in a single annotator with post processing rules (SLR) from which fetal RR and fetal heart rate (FHR) measures can be computed. Data from PhysioNet with reference fetal QRS locations was considered for validation, with SLR outperforming SL including ICA based detections. The error in estimated FHR using SLR was lower than 20 bpm for more than 80% of the processed files. The median error in 1 min based FHR estimation was 0.13 bpm, with a correlation between reference and estimated FHR of 0.48, which increased to 0.73 when considering only records for which estimated FHR > 110 bpm. This allows us to conclude that the proposed methodology is able to provide a clinically useful estimation of the FHR.

  17. Ischemic Ventricular Tachycardia Presenting as a Narrow Complex Tachycardia

    PubMed Central

    Page, Stephen P; Watts, Troy; Yeo, Wee Tiong; Mehul, Dhinoja

    2014-01-01

    This report describes a patient presenting with a narrow complex tachycardia in the context of prior myocardial infarction and impaired ventricular function. Electrophysiological studies confirmed ventricular tachycardia and activation and entrainment mapping demonstrated a critical isthmus within an area of scar involving the His-Purkinje system accounting for the narrow QRS morphology. This very rare case shares some similarities with upper septal ventricular tachycardia seen in patients with structurally normal hearts, but to our knowledge has not been seen previously in patients with ischemic heart disease. PMID:25057222

  18. A new method for QRS detection in ECG signals using QRS-preserving filtering techniques.

    PubMed

    Sharma, Tanushree; Sharma, Kamalesh K

    2018-03-28

    Detection of QRS complexes in ECG signals is required for various purposes such as determination of heart rate, feature extraction and classification. The problem of automatic QRS detection in ECG signals is complicated by the presence of noise spectrally overlapping with the QRS frequency range. As a solution to this problem, we propose the use of least-squares-optimisation-based smoothing techniques that suppress the noise peaks in the ECG while preserving the QRS complexes. We also propose a novel nonlinear transformation technique that is applied after the smoothing operations, which equalises the QRS amplitudes without boosting the supressed noise peaks. After these preprocessing operations, the R-peaks can finally be detected with high accuracy. The proposed technique has a low computational load and, therefore, it can be used for real-time QRS detection in a wearable device such as a Holter monitor or for fast offline QRS detection. The offline and real-time versions of the proposed technique have been evaluated on the standard MIT-BIH database. The offline implementation is found to perform better than state-of-the-art techniques based on wavelet transforms, empirical mode decomposition, etc. and the real-time implementation also shows improved performance over existing real-time QRS detection techniques.

  19. Comparison of the calculation QRS angle for bundle branch block detection

    NASA Astrophysics Data System (ADS)

    Goeirmanto, L.; Mengko, R.; Rajab, T. L.

    2016-04-01

    QRS angle represent condition of blood circulation in the heart. Normally QRS angle is between -30 until 90 degree. Left Axis Defiation (LAD) and Right Axis Defiation (RAD) are abnormality conditions that lead to Bundle Branch Block. QRS angle is calculated using common method from physicians and compared to mathematical method using difference amplitudos and difference areas. We analyzed the standard 12 lead electrocardiogram data from MITBIH physiobank database. All methods using lead I and lead avF produce similar QRS angle and right QRS axis quadrant. QRS angle from mathematical method using difference areas is close to common method from physician. Mathematical method using difference areas can be used as a trigger for detecting heart condition.

  20. Detecting drug-induced prolongation of the QRS complex: New insights for cardiac safety assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cros, C., E-mail: caroline.cros@hotmail.co.uk; Skinner, M., E-mail: Matthew.Skinner@astrazeneca.com; Moors, J.

    Background: Drugs slowing the conduction of the cardiac action potential and prolonging QRS complex duration by blocking the sodium current (I{sub Na}) may carry pro-arrhythmic risks. Due to the frequency-dependent block of I{sub Na}, this study assesses whether activity-related spontaneous increases in heart rate (HR) occurring during standard dog telemetry studies can be used to optimise the detection of class I antiarrhythmic-induced QRS prolongation. Methods: Telemetered dogs were orally dosed with quinidine (class Ia), mexiletine (class Ib) or flecainide (class Ic). QRS duration was determined standardly (5 beats averaged at rest) but also prior to and at the plateau ofmore » each acute increase in HR (3 beats averaged at steady state), and averaged over 1 h period from 1 h pre-dose to 5 h post-dose. Results: Compared to time-matched vehicle, at rest, only quinidine and flecainide induced increases in QRS duration (E{sub max} 13% and 20% respectively, P < 0.01–0.001) whereas mexiletine had no effect. Importantly, the increase in QRS duration was enhanced at peak HR with an additional effect of + 0.7 ± 0.5 ms (quinidine, NS), + 1.8 ± 0.8 ms (mexiletine, P < 0.05) and + 2.8 ± 0.8 ms (flecainide, P < 0.01) (calculated as QRS at basal HR-QRS at high HR). Conclusion: Electrocardiogram recordings during elevated HR, not considered during routine analysis optimised for detecting QT prolongation, can be used to sensitise the detection of QRS prolongation. This could prove useful when borderline QRS effects are detected. Analysing during acute increases in HR could also be useful for detecting drug-induced effects on other aspects of cardiac function. -- Highlights: ► We aimed to improve detection of drug-induced QRS prolongation in safety screening. ► We used telemetered dogs to test class I antiarrhythmics at low and high heart rate. ► At low heart rate only quinidine and flecainide induced an increase in QRS duration. ► At high heart rate the effects

  1. Association between QRS duration and obstructive sleep apnea.

    PubMed

    Gupta, Shuchita; Cepeda-Valery, Beatriz; Romero-Corral, Abel; Shamsuzzaman, Abu; Somers, Virend K; Pressman, Gregg S

    2012-12-15

    Both obstructive sleep apnea (OSA) and prolonged QRS duration are associated with hypertension, heart failure, and sudden cardiac death. However, possible links between QRS duration and OSA have not been explored. Cross-sectional study of 221 patients who underwent polysomnography at our center. Demographics, cardiovascular risk factors and ECG were collected to explore a relationship between OSA and QRS duration. The apnea-hypopnea index (AHI) was positively correlated with QRS duration (r = 0.141, p = 0.03). Patients were divided into 3 groups: AHI < 5 (61), AHI 5-29 (104), and AHI > 30 (55). The mean QRS duration prolonged significantly as OSA worsened (AHI < 5, 85 ± 9.5; AHI 5-29, 89 ± 11.9; and AHI > 30, 95 ± 19.9 ms, p = 0.001). QRS ≥ 100 ms was present in 12.7% of patients with severe OSA compared with 0% in the rest of the sample (p < 0.0001). After adjustment for age, race, and cardiovascular risk factors, this association remained significant in women but not in men. QRS duration and OSA were significantly associated. Severity of OSA independently predicted prolonged QRS in women but not men. Nevertheless, prolongation of QRS duration in either sex may potentiate arrhythmic risks associated with OSA.

  2. QRS duration predicts death and hospitalization among patients with atrial fibrillation irrespective of heart failure: evidence from the AFFIRM study

    PubMed Central

    Whitbeck, Matthew G.; Charnigo, Richard J.; Shah, Jignesh; Morales, Gustavo; Leung, Steve W.; Fornwalt, Brandon; Bailey, Alison L.; Ziada, Khaled; Sorrell, Vincent L.; Zegarra, Milagros M.; Thompson, Jenks; Hosn, Neil Aboul; Campbell, Charles L.; Gurley, John; Anaya, Paul; Booth, David C.; Biase, Luigi Di; Natale, Andrea; Smyth, Susan; Moliterno, David J.; Elayi, Claude S.

    2014-01-01

    Aims The association of QRS duration (QRSd) with morbidity and mortality is understudied in patients with atrial fibrillation (AF). We sought to assess any association of prolonged QRS with increased risk of death or hospitalization among patients with AF. Methods and results QRS duration was retrieved from the baseline electrocardiograms of patients enroled in the Atrial Fibrillation Follow-Up Investigation of Rhythm Management (AFFIRM) study and divided into three categories: <90, 90–119, ≥120 ms. Cox models were applied relating the hazards of mortality and hospitalizations to QRSd. Among 3804 patients with AF, 593 died and 2305 were hospitalized. Compared with those with QRS < 90 ms, patients with QRS ≥ 120 ms, had an increased mortality [hazard ratio (HR) 1.61, 95% confidence interval (CI): 1.29–2.03, P < 0.001] and hospitalizations (HR 1.14, 95% CI: 1.07–1.34, P = 0.043) over an average follow-up of 3.5 years. Importantly, for patients with QRS 90–119 ms, mortality and hospitalization were also increased (HR 1.31, P = 0.005 and 1.11, P = 0.026, respectively). In subgroup analysis based on heart failure (HF) status (previously documented or ejection fraction <40%), mortality was increased for QRS ≥ 120 ms patients with (HR 1.87, P < 0.001) and without HF (HR 1.63, P = 0.02). In the QRS 90–119 ms group, mortality was increased (HR 1.38, P = 0.03) for those with HF, but not significantly among those without HF (HR 1.23, P = 0.14). Conclusion Among patients with AF, QRSd ≥ 120 ms was associated with a substantially increased risk for mortality (all-cause, cardiovascular, and arrhythmic) and hospitalization. Interestingly, an increased mortality was also observed among those with QRS 90–119 ms and concomitant HF. PMID:24368753

  3. Assessments of the QT/QRS restitution in perfused guinea-pig heart can discriminate safe and arrhythmogenic drugs.

    PubMed

    Osadchii, Oleg E

    2017-09-01

    Drug-induced arrhythmia remains a matter of serious clinical concern, partly due to low prognostic value of currently available arrhythmic biomarkers. This study examined whether arrhythmogenic risks can be predicted through assessments of the rate adaptation of QT interval, ventricular effective refractory period (ERP), or the QT/QRS ratio, in perfused guinea-pig hearts. When the maximum restitution slope was taken as a metric of proarrhythmia, neither QT interval nor ERP measurements at progressively increased pacing rates were found to fully discriminate arrhythmogenic drugs (dofetilide, quinidine, flecainide, and procainamide) from those recognized as safe antiarrhythmics (lidocaine and mexiletine). For example, the slope of QT restitution was increased by dofetilide and quinidine, but remained unchanged by flecainide, procainamide, lidocaine, and mexiletine. With ERP rate adaptation, even though the restitution slope was increased by dofetilide, all class I agents reduced the slope value independently of their safety profile. The QRS measurements revealed variable drug effects, ranging from significant use-dependent conduction slowing (flecainide, quinidine, and procainamide) to only modest increase in QRS (lidocaine and mexiletine), or no change at all (dofetilide). However, with the QT/QRS rate adaptation, the restitution slope was significantly increased by all agents which have been reported to produce proarrhythmic effects (dofetilide, quinidine, flecainide, and procainamide), but not changed by lidocaine and mexiletine. These findings suggest that the slope of the QT/QRS rate adaptation can be considered as a novel electrophysiological biomarker in predicting potential arrhythmic risks associated with pharmacotherapy in cardiac patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Association between QRS Duration and Obstructive Sleep Apnea

    PubMed Central

    Gupta, Shuchita; Cepeda-Valery, Beatriz; Romero-Corral, Abel; Shamsuzzaman, Abu; Somers, Virend K.; Pressman, Gregg S.

    2012-01-01

    Background: Both obstructive sleep apnea (OSA) and prolonged QRS duration are associated with hypertension, heart failure, and sudden cardiac death. However, possible links between QRS duration and OSA have not been explored. Methods: Cross-sectional study of 221 patients who underwent polysomnography at our center. Demographics, cardiovascular risk factors and ECG were collected to explore a relationship between OSA and QRS duration. Results: The apnea-hypopnea index (AHI) was positively correlated with QRS duration (r = 0.141, p = 0.03). Patients were divided into 3 groups: AHI < 5 (61), AHI 5-29 (104), and AHI > 30 (55). The mean QRS duration prolonged significantly as OSA worsened (AHI < 5, 85 ± 9.5; AHI 5-29, 89 ± 11.9; and AHI > 30, 95 ± 19.9 ms, p = 0.001). QRS ≥ 100 ms was present in 12.7% of patients with severe OSA compared with 0% in the rest of the sample (p < 0.0001). After adjustment for age, race, and cardiovascular risk factors, this association remained significant in women but not in men. Conclusion: QRS duration and OSA were significantly associated. Severity of OSA independently predicted prolonged QRS in women but not men. Nevertheless, prolongation of QRS duration in either sex may potentiate arrhythmic risks associated with OSA. Citation: Gupta S; Cepeda-Valery B; Romero-Corral A; Shamsuzzaman A; Somers VK; Pressman GS. Association between QRS duration and obstructive sleep apnea. J Clin Sleep Med 2012;8(6):649-654. PMID:23243398

  5. Prolonged QRS Widening After Aripiprazole Overdose.

    PubMed

    Mazer-Amirshahi, Maryann; Porter, Robert; Dewey, Kayla

    2018-05-05

    Aripiprazole is an atypical antipsychotic with a long half-life. Overdose can result in protracted somnolence and cardiac disturbances, particularly QT interval prolongation. This is a single case report of a 14-year-old boy who took an overdose of aripiprazole and developed QRS widening. A 14-year-old boy intentionally ingested 20 tablets of aripiprazole (5 mg). He was brought to the emergency department when his ingestion was discovered. The patient's vital signs were as follows: temperature, 37.7°C; heart rate, 108 beats/min; blood pressure, 138/98 mm Hg; and respirations, 16 breaths/min. Activated charcoal was administered within 90 minutes of ingestion. Initial electrocardiogram (EKG) showed sinus tachycardia, with a QRS of 138 ms and QT interval of 444 ms. QRS duration was 90 ms on an EKG performed 3 months earlier. A bolus of sodium bicarbonate was administered, and the patient was transferred to the pediatric intensive care unit. Repeat EKG demonstrated a QRS of 156 ms, and a sodium bicarbonate infusion was initiated. The patient continued to have QRS prolongation for the next 8 days, reaching a peak of 172 ms 3 days postingestion. Despite aggressive treatment with sodium bicarbonate, there was persistent QRS prolongation; however, the patient did not have any dysrhythmias and remained hemodynamically stable. The patient was discharged 9 days postingestion when the QRS duration normalized to 82 ms. Genetic testing revealed that the patient was a CYP2D6 poor metabolizer. This case suggests that aripiprazole toxicity may possibly be associated with QRS prolongation without associated dysrhythmias or cardiovascular compromise. In addition, toxicity may be prolonged in patients who are CYP2D6 poor metabolizers.

  6. Fragmented QRS and prediction of paroxysmal atrial fibrillation episodes

    PubMed Central

    Temiz, Ahmet; Gazi, Emine; Güngör, Ömer; Altun, Burak; Barutcu, Ahmet; Bekler, Adem; Tan, Yusuf Ziya; Ozcan, Sedat; Yener, Ali Ümit; Kurt, Tolga

    2014-01-01

    Objective: Prior studies have demonstrated the relationship between cardiovascular diseases and fragmented QRS (fQRS). fQRS was also associated with ventricular arrhythmias. Our objective was to find out the relationship between fQRS and paroxysmal atrial fibrillation (PAF). Method: A total of 301 patients without overt structural heart disease were prospectively included in the study. Patients were divided in to 2 groups according to presence of fQRS. Multivariate logistic regression analysis was used to assess the predictive value of fQRS for predicting PAF. Results: One hundred and three patients had fQRS. Patients with fQRS were older (53±16.8 vs 45.3±17.2, p<0.001), with larger left atrium (LA) (33.2±5.9 vs 30.1±5.9 mm, p=0.001), with thicker interventricular septum (IVS) (10.2±1.9 vs 9.5±2.3 mm, p=0.032), more diabetic (19.8 vs 10.6%, p=0.029) and have more PAF episodes (22.3 vs 4.1%, p<0.001) in comparison with patients without fQRS. fQRS was an independent predictor of detecting PAF episode (odds ratio, 9.69; 95% confidence interval, 2.46-38.15, p=0.001). Hypertension and diabetes mellitus were also predictive. Conclusion: The presence of fQRS independently predicted PAF episodes in holter monitoring (HM). Further studies are needed to clarify the clinical implications of this finding. PMID:25097533

  7. Wide QRS tachycardia: what is the rhythm?

    PubMed

    Rosman, Jonathan; Tawil, Joseph; Hanon, Sam; Schweitzer, Paul

    2006-10-01

    We report a case of an elderly man who presented to the emergency room complaining of palpitations. Electrocardiogram revealed wide QRS tachycardia with a narrow beat within the tachycardia. Most commonly, a narrow complex beat during a wide complex tachycardia suggests a capture or fusion beat in the setting of ventricular tachycardia. However, there are situations where supraventricular tachycardia can also manifest this way. In our patient a pacemaker interrogation clarified the diagnosis.

  8. Algorithm for detection the QRS complexes based on support vector machine

    NASA Astrophysics Data System (ADS)

    Van, G. V.; Podmasteryev, K. V.

    2017-11-01

    The efficiency of computer ECG analysis depends on the accurate detection of QRS-complexes. This paper presents an algorithm for QRS complex detection based of support vector machine (SVM). The proposed algorithm is evaluated on annotated standard databases such as MIT-BIH Arrhythmia database. The QRS detector obtained a sensitivity Se = 98.32% and specificity Sp = 95.46% for MIT-BIH Arrhythmia database. This algorithm can be used as the basis for the software to diagnose electrical activity of the heart.

  9. Sodium channel blockade with QRS widening after an escitalopram overdose.

    PubMed

    Schreffler, Susan M; Marraffa, Jeanna M; Stork, Christine M; Mackey, Jennifer

    2013-09-01

    Escitalopram is rarely associated with prolongation of the QTc interval; however, there are no reported cases of QRS complex widening associated with escitalopram overdose. We report a case of a patient who presented with both QRS complex widening and QTc interval prolongation after an escitalopram overdose. A 16-year-old girl presented to the emergency department after ingestion of escitalopram, tramadol/acetaminophen, and hydrocodone/acetaminophen. Laboratory results were significant for 4-hour acetaminophen 21.1 μg/mL. Serum electrolytes including potassium, magnesium, and calcium were all normal. Initial electrocardiogram (ECG) revealed a widened QRS with an incomplete right bundle branch pattern. After administration of 100-mEq sodium bicarbonate, a repeat ECG revealed narrowing of the QRS complex and a prolonged QTc interval. Magnesium sulfate 2 g intravenous and sodium bicarbonate drip were initiated. A repeat ECG, 1 hour after the second, revealed normalization of the QRS complex and QTc interval. Prolongation of the QTc interval is an expected effect of escitalopram. Both escitalopram and citalopram are metabolized to the cardiotoxic metabolite S-didesmethylcitalopram and didesmethylcitalopram, respectively, which have been implicated in numerous cardiac abnormalities including widening of the QRS complex. Although never previously described with escitalopram, this mechanism provides a reasonable explanation for the QRS complex widening and incomplete right bundle branch block that occurred in our patient. Both QRS complex widening and QTc interval prolongation should be monitored in cases of escitalopram and citalopram overdoses.

  10. Microcontroller-based real-time QRS detection.

    PubMed

    Sun, Y; Suppappola, S; Wrublewski, T A

    1992-01-01

    The authors describe the design of a system for real-time detection of QRS complexes in the electrocardiogram based on a single-chip microcontroller (Motorola 68HC811). A systematic analysis of the instrumentation requirements for QRS detection and of the various design techniques is also given. Detection algorithms using different nonlinear transforms for the enhancement of QRS complexes are evaluated by using the ECG database of the American Heart Association. The results show that the nonlinear transform involving multiplication of three adjacent, sign-consistent differences in the time domain gives a good performance and a quick response. When implemented with an appropriate sampling rate, this algorithm is also capable of rejecting pacemaker spikes. The eight-bit single-chip microcontroller provides sufficient throughput and shows a satisfactory performance. Implementation of multiple detection algorithms in the same system improves flexibility and reliability. The low chip count in the design also favors maintainability and cost-effectiveness.

  11. Envelopment filter and K-means for the detection of QRS waveforms in electrocardiogram.

    PubMed

    Merino, Manuel; Gómez, Isabel María; Molina, Alberto J

    2015-06-01

    The electrocardiogram (ECG) is a well-established technique for determining the electrical activity of the heart and studying its diseases. One of the most common pieces of information that can be read from the ECG is the heart rate (HR) through the detection of its most prominent feature: the QRS complex. This paper describes an offline version and a real-time implementation of a new algorithm to determine QRS localization in the ECG signal based on its envelopment and K-means clustering algorithm. The envelopment is used to obtain a signal with only QRS complexes, deleting P, T, and U waves and baseline wander. Two moving average filters are applied to smooth data. The K-means algorithm classifies data into QRS and non-QRS. The technique is validated using 22 h of ECG data from five Physionet databases. These databases were arbitrarily selected to analyze different morphologies of QRS complexes: three stored data with cardiac pathologies, and two had data with normal heartbeats. The algorithm has a low computational load, with no decision thresholds. Furthermore, it does not require any additional parameter. Sensitivity, positive prediction and accuracy from results are over 99.7%. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  12. Analysis Spectrum of ECG Signal and QRS Detection during Running on Treadmill

    NASA Astrophysics Data System (ADS)

    Agung Suhendra, M.; Ilham R., M.; Simbolon, Artha I.; Faizal A., M.; Munandar, A.

    2018-03-01

    The heart is an important organ in our metabolism in which it controls circulatory and oxygen. The heart exercise is needed one of them using the treadmill to prevent health. To analysis, it using electrocardiograph (ECG) to investigating and diagnosing anomalies of the heart. In this paper, we would like to analysis ECG signals during running on the treadmill with kinds of speeds. There are two analysis ECG signals i.e. QRS detection and power spectrum density (PSD). The result of PSD showed that subject 3 has highly for all subject and the result of QRS detection using pan Tomkins algorithm that a percentage of failed detection is an approaching to 0 % for all subject.

  13. Ventricular conduction and long-term heart failure outcomes and mortality in African Americans: insights from the Jackson Heart Study.

    PubMed

    Mentz, Robert J; Greiner, Melissa A; DeVore, Adam D; Dunlay, Shannon M; Choudhary, Gaurav; Ahmad, Tariq; Khazanie, Prateeti; Randolph, Tiffany C; Griswold, Michael E; Eapen, Zubin J; O'Brien, Emily C; Thomas, Kevin L; Curtis, Lesley H; Hernandez, Adrian F

    2015-03-01

    QRS prolongation is associated with adverse outcomes in mostly white populations, but its clinical significance is not well established for other groups. We investigated the association between QRS duration and mortality in African Americans. We analyzed data from 5146 African Americans in the Jackson Heart Study stratified by QRS duration on baseline 12-lead ECG. We defined QRS prolongation as QRS≥100 ms. We assessed the association between QRS duration and all-cause mortality using Cox proportional hazards models and reported the cumulative incidence of heart failure hospitalization. We identified factors associated with the development of QRS prolongation in patients with normal baseline QRS. At baseline, 30% (n=1528) of participants had QRS prolongation. The cumulative incidences of mortality and heart failure hospitalization were greater with versus without baseline QRS prolongation: 12.6% (95% confidence interval [CI], 11.0-14.4) versus 7.1% (95% CI, 6.3-8.0) and 8.2% (95% CI, 6.9-9.7) versus 4.4% (95% CI, 3.7-5.1), respectively. After risk adjustment, QRS prolongation was associated with increased mortality (hazard ratio, 1.27; 95% CI, 1.03-1.56; P=0.02). There was a linear relationship between QRS duration and mortality (hazard ratio per 10 ms increase, 1.06; 95% CI, 1.01-1.12). Older age, male sex, prior myocardial infarction, lower ejection fraction, left ventricular hypertrophy, and left ventricular dilatation were associated with the development of QRS prolongation. QRS prolongation in African Americans was associated with increased mortality and heart failure hospitalization. Factors associated with developing QRS prolongation included age, male sex, prior myocardial infarction, and left ventricular structural abnormalities. © 2015 American Heart Association, Inc.

  14. Robust QRS peak detection by multimodal information fusion of ECG and blood pressure signals.

    PubMed

    Ding, Quan; Bai, Yong; Erol, Yusuf Bugra; Salas-Boni, Rebeca; Zhang, Xiaorong; Hu, Xiao

    2016-11-01

    QRS peak detection is a challenging problem when ECG signal is corrupted. However, additional physiological signals may also provide information about the QRS position. In this study, we focus on a unique benchmark provided by PhysioNet/Computing in Cardiology Challenge 2014 and Physiological Measurement focus issue: robust detection of heart beats in multimodal data, which aimed to explore robust methods for QRS detection in multimodal physiological signals. A dataset of 200 training and 210 testing records are used, where the testing records are hidden for evaluating the performance only. An information fusion framework for robust QRS detection is proposed by leveraging existing ECG and ABP analysis tools and combining heart beats derived from different sources. Results show that our approach achieves an overall accuracy of 90.94% and 88.66% on the training and testing datasets, respectively. Furthermore, we observe expected performance at each step of the proposed approach, as an evidence of the effectiveness of our approach. Discussion on the limitations of our approach is also provided.

  15. QRS Width as a Predictor of Right Ventricular Remodeling After Percutaneous Pulmonary Valve Implantation.

    PubMed

    Paech, C; Dähnert, I; Riede, F T; Wagner, R; Kister, T; Nieschke, K; Wagner, F; Gebauer, R A

    2017-08-01

    Recent data showed a right ventricular dyssynchrony in patients with tetralogy of Fallot (TOF). Percutaneous pulmonary valve implantation (PPVI) has become an important procedure to treat a pulmonary stenosis and/or regurgitation of the right ventricular outflow tract in these patients. Despite providing good results, there is still a considerable number of nonresponders to PPVI. The authors speculated that electrical dysfunction of the right ventricle plays an underestimated role in the outcome of patients after PPVI. This study aimed to investigate the influence of right ventricular electrical dysfunction, i.e., right bundle branch block (RBBB) on the RV remodeling after PPVI. The study included consecutive patients after correction of TOF with or without RBBB, who had received a PPVI previously at the Heart Center of the University of Leipzig, Germany during the period from 2012 to 2015. 24 patients were included. Patients without RBBB, i.e., with narrow QRS complexes pre-intervention, had significantly better RV function and had smaller right ventricular volumes. Patients with pre-interventionally QRS width below 150 ms showed a post-interventional remodeling of the right ventricle with the decreasing RV volumes (p = 0.001). The parameters of LV function and volume as well as RV ejection fraction remained unaffected by RBBB. The presented data indicate that the QRS width seems to be a valuable parameter in the prediction of right ventricular remodeling after PPVI, as it represents both electrical and mechanical functions of the right ventricle and may serve as an additional parameter for optimal timing of a PPVI.

  16. Relation of QRS duration to mortality in a community-based cohort with hypertrophic cardiomyopathy.

    PubMed

    Bongioanni, Sergio; Bianchi, Francesca; Migliardi, Alessandro; Gnavi, Roberto; Pron, Paolo Giay; Casetta, Marzia; Conte, Maria Rosa

    2007-08-01

    A prolonged QRS duration on the standard electrocardiogram is associated with an increased risk of cardiovascular death in cardiomyopathies of different origin. However, the relation between QRS duration and prognosis in hypertrophic cardiomyopathy (HC) remains undefined. We assessed the relation between QRS duration and cardiovascular death in 241 consecutive patients with HC. The study cohort was divided into 2 groups according to QRS duration: <120 and > or =120 ms. Of the 241 patients, 191 (79%) had a QRS duration <120 ms and 50 (21%) a QRS duration > or =120 ms. During a mean follow-up of 7.9 +/- 5.1 years, 35 patients died of cardiovascular causes related to HC. Of these 35 patients, 13 (6%) had a QRS duration <120 ms and 22 (43%) had a QRS duration > or =120 ms (p <0.01). Risk of cardiovascular death was significantly higher in patients with a QRS duration > or =120 ms than in those with a QRS duration <120 ms (relative risk 5.2, p <0.0001). At 8-year follow-up, cumulative risks of HC-related death were 7.1% in patients with a QRS duration <120 ms and 55% in those with a QRS duration > or =120 ms. Multivariate analysis confirmed that a QRS duration > or =120 ms was independently associated with an increased risk of cardiovascular death (hazard ratio 3.2, p = 0.007). New York Heart Association functional class III/IV was the only other clinical variable significantly and independently associated with an increased risk of cardiovascular death. In conclusion, in patients with HC, QRS duration on standard electrocardiogram is directly related to cardiovascular mortality, and a QRS duration > or =120 ms is a strong and independent predictor of prognosis.

  17. Where is the exact origin of narrow premature ventricular contractions manifesting qR in inferior wall leads?

    PubMed

    Zheng, Cheng; Li, Jin; Lin, Jia-Xuan; Wang, Lu-Ping; Lin, Jia-Feng

    2016-04-04

    In recent years, radiofrequency catheter ablation(RFCA) has been established as an effective therapy for idiopathic premature ventricular contractions (PVCs), however, its effect on the narrow PVCs (QRS duration < 130 msec) with qR pattern in inferior leads, may not been fully concluded. Characteristics of 12-lead electrocardiogram (ECG) and electrophysiologic recordings were analyzed in 40 patients with symptomatic PVCs manifesting narrow QRS complex with qR pattern in inferior leads. The procedure of RFCA was performed based on pace mapping and activation mapping. Among the 40 patients with narrow PVCs, complete elimination of PVCs was achieved by RFCA in 35 patients during a median follow-up period of 23 months. Successful ablation was achieved on 19 patients at the sites where earliest Purkinje potentials were recorded in left ventricular anterosuperior septum, thus PVCs arising from left anterior fascicle (LAF) were confirmed, for these PVCs, the QRS morphology were right bundle branch and left posterior fascicle block (RBBB + LPFB) with rightward axis, the average QRS duration 116.07 ± 7.96 ms, R or rsR'in lead V1,with transition zone ahead of lead V1 in precordial leads. Another 16 successful RFCA were achieved by energy delivery at interleaflet triangle(ILT) between right coronary cusp(RCC) and left coronary cusp(LCC) where no Purkinje potentials were recorded, for narrow PVCs arising from the L-RCC ILT, the QRS morphology were similar to the PVCs arising from LAF but much narrower in QRS duration (100.44 ± 3.49 vs. 116.07 ± 7.96 ms, p < 0.05), they were also R or Rs in lead V1 with the transition zone ahead of lead V1. For 5 symptomatic narrow PVCs failed to the procedure of RFCA, their electrocardiographic characteristics showed that the narrowest QRS duration (91.80 ± 6.94 vs. 100.44 ± 3.49, 116.07 ± 7.96 ms, p < 0.05), rs or rS (r/s or r/S≦1) morphology in lead V1 with the precordial transition zone behind lead V3. Most of idiopathic PVCs of

  18. A QRS Detection and R Point Recognition Method for Wearable Single-Lead ECG Devices.

    PubMed

    Chen, Chieh-Li; Chuang, Chun-Te

    2017-08-26

    In the new-generation wearable Electrocardiogram (ECG) system, signal processing with low power consumption is required to transmit data when detecting dangerous rhythms and to record signals when detecting abnormal rhythms. The QRS complex is a combination of three of the graphic deflection seen on a typical ECG. This study proposes a real-time QRS detection and R point recognition method with low computational complexity while maintaining a high accuracy. The enhancement of QRS segments and restraining of P and T waves are carried out by the proposed ECG signal transformation, which also leads to the elimination of baseline wandering. In this study, the QRS fiducial point is determined based on the detected crests and troughs of the transformed signal. Subsequently, the R point can be recognized based on four QRS waveform templates and preliminary heart rhythm classification can be also achieved at the same time. The performance of the proposed approach is demonstrated using the benchmark of the MIT-BIH Arrhythmia Database, where the QRS detected sensitivity (Se) and positive prediction (+P) are 99.82% and 99.81%, respectively. The result reveals the approach's advantage of low computational complexity, as well as the feasibility of the real-time application on a mobile phone and an embedded system.

  19. Benefits of Permanent His Bundle Pacing Combined With Atrioventricular Node Ablation in Atrial Fibrillation Patients With Heart Failure With Both Preserved and Reduced Left Ventricular Ejection Fraction.

    PubMed

    Huang, Weijian; Su, Lan; Wu, Shengjie; Xu, Lei; Xiao, Fangyi; Zhou, Xiaohong; Ellenbogen, Kenneth A

    2017-04-01

    Clinical benefits from His bundle pacing (HBP) in heart failure patients with preserved and reduced left ventricular ejection fraction are still inconclusive. This study evaluated clinical outcomes of permanent HBP in atrial fibrillation patients with narrow QRS who underwent atrioventricular node ablation for heart failure symptoms despite rate control by medication. The study enrolled 52 consecutive heart failure patients who underwent attempted atrioventricular node ablation and HBP for symptomatic atrial fibrillation. Echocardiographic left ventricular ejection fraction and left ventricular end-diastolic dimension, New York Heart Association classification and use of diuretics for heart failure were assessed during follow-up visits after permanent HBP. Of 52 patients, 42 patients (80.8%) received permanent HBP and atrioventricular node ablation with a median 20-month follow-up. There was no significant change between native and paced QRS duration (107.1±25.8 versus 105.3±23.9 milliseconds, P =0.07). Left ventricular end-diastolic dimension decreased from the baseline ( P <0.001), and left ventricular ejection fraction increased from baseline ( P <0.001) in patients with a greater improvement in heart failure with reduced ejection fraction patients (N=20) than in heart failure with preserved ejection fraction patients (N=22). New York Heart Association classification improved from a baseline 2.9±0.6 to 1.4±0.4 after HBP in heart failure with reduced ejection fraction patients and from a baseline 2.7±0.6 to 1.4±0.5 after HBP in heart failure with preserved ejection fraction patients. After 1 year of HBP, the numbers of patients who used diuretics for heart failure decreased significantly ( P <0.001) when compared to the baseline diuretics use. Permanent HBP post-atrioventricular node ablation significantly improved echocardiographic measurements and New York Heart Association classification and reduced diuretics use for heart failure management in atrial

  20. Clinical significance of fragmented QRS complexes or J waves in patients with idiopathic ventricular arrhythmias.

    PubMed

    Seong, Choong Sil; Gwag, Hye Bin; Hwang, Jin Kyung; Park, Seung Jung; Park, Kyoung-Min; Kim, June Soo; On, Young Keun

    2018-01-01

    Idiopathic ventricular fibrillation (IVF) can cause sudden cardiac death. Previous studies have reported that J waves and fragmented QRS complexes (f-QRS) are arrhythmogenic markers and predictors of cardiac events. We evaluated the prevalence and clinical significance of J waves and f-QRS in patients with IVF. We studied 81 patients who received an implantable cardioverter defibrillator (ICD) due to IVF between October 1999 and June 2015. We assessed the prevalence of J waves and f-QRS using electrocardiograms (ECGs). Patients were classified into three groups: J wave group (n = 35), f-QRS group (n = 20), or normal ECG group (n = 26). The control group included 81 subjects without heart disease who were matched for age, sex, and race. We compared syncope, sudden cardiac arrest, and appropriate ICD shock between the three groups. The follow-up duration was 4.1 years. J waves and f-QRS were more frequent in patients with IVF than in control subjects (43.2%, 21% vs. 24.7%, 19.7%, P < 0.001). Out of the three groups, clinical cardiac events were most frequent in the f-QRS group (50% vs. 45.7% vs. 11.5%, P = 0.028). A comparison of the combined group of J wave and f-QRS versus the normal ECG group revealed that the combined group had a higher frequency of clinical cardiac events than the normal ECG group (47.3% vs. 11.5%, respectively, P = 0.009). Patients with IVF had higher prevalence of f-QRS or J waves. And patients with f-QRS or J waves were at higher risk of recurrent ventricular fibrillation.

  1. QRS complex detection based on continuous density hidden Markov models using univariate observations

    NASA Astrophysics Data System (ADS)

    Sotelo, S.; Arenas, W.; Altuve, M.

    2018-04-01

    In the electrocardiogram (ECG), the detection of QRS complexes is a fundamental step in the ECG signal processing chain since it allows the determination of other characteristics waves of the ECG and provides information about heart rate variability. In this work, an automatic QRS complex detector based on continuous density hidden Markov models (HMM) is proposed. HMM were trained using univariate observation sequences taken either from QRS complexes or their derivatives. The detection approach is based on the log-likelihood comparison of the observation sequence with a fixed threshold. A sliding window was used to obtain the observation sequence to be evaluated by the model. The threshold was optimized by receiver operating characteristic curves. Sensitivity (Sen), specificity (Spc) and F1 score were used to evaluate the detection performance. The approach was validated using ECG recordings from the MIT-BIH Arrhythmia database. A 6-fold cross-validation shows that the best detection performance was achieved with 2 states HMM trained with QRS complexes sequences (Sen = 0.668, Spc = 0.360 and F1 = 0.309). We concluded that these univariate sequences provide enough information to characterize the QRS complex dynamics from HMM. Future works are directed to the use of multivariate observations to increase the detection performance.

  2. Device therapy in heart failure with reduced ejection fraction-cardiac resynchronization therapy and more.

    PubMed

    Duncker, D; Veltmann, C

    2018-05-09

    In patients with heart failure with reduced ejection fraction (HFrEF), optimal medical treatment includes beta-blockers, ACE inhibitors/angiotensinreceptor-neprilysin inhibitors (ARNI), mineralocorticoid receptor antagonists, and ivabradine when indicated. In device therapy of HFrEF, implantable cardioverter-defibrillators and cardiac resynchronization therapy (CRT) have been established for many years. CRT is the therapy of choice (class I indication) in symptomatic patients with HFrEF and a broad QRS complex with a left bundle branch block (LBBB) morphology. However, the vast majority of heart failure patients show a narrow QRS complex or a non-LBBB morphology. These patients are not candidates for CRT and alternative electrical therapies such as baroreflex activation therapy (BAT) and cardiac contractility modulation (CCM) may be considered. BAT modulates vegetative dysregulation in heart failure. CCM improves contractility, functional capacity, and symptoms. Although a broad data set is available for BAT and CCM, mortality data are still lacking for both methods. This article provides an overview of the device-based therapeutic options for patients with HFrEF.

  3. The Shortest QRS Duration of an Electrocardiogram Might Be an Optimal Electrocardiographic Predictor for Response to Cardiac Resynchronization Therapy.

    PubMed

    Chen, Jan-Yow; Lin, Kuo-Hung; Chang, Kuan-Cheng; Chou, Che-Yi

    2017-08-03

    QRS duration has been associated with the response to cardiac resynchronization therapy (CRT). However, the methods for defining QRS duration to predict the outcome of CRT have discrepancies in previous reports. The aim of this study was to determine an optimal measurement of QRS duration to predict the response to CRT.Sixty-one patients who received CRT were analyzed. All patients had class III-IV heart failure, left ventricular ejection fraction not more than 35%, and complete left bundle branch block. The shortest, longest, and average QRS durations from the 12 leads of each electrocardiogram (ECG) were measured. The responses to CRT were determined using the changes in echocardiography after 6 months. Thirty-five (57.4%) patients were responders and 26 (42.6%) patients were non-responders. The pre-procedure shortest, average, and longest QRS durations and the QRS shortening (ΔQRS) of the shortest QRS duration were significantly associated with the response to CRT in a univariate logistic regression analysis (P = 0.002, P = 0.03, P = 0.04 and P = 0.04, respectively). Based on the measurement of the area under curve of the receiver operating characteristic curve, only the pre-procedure shortest QRS duration and the ΔQRS of the shortest QRS duration showed significant discrimination for the response to CRT (P = 0.002 and P = 0.038, respectively). Multivariable logistic regression showed the pre-procedure shortest QRS duration is an independent predictor for the response to CRT.The shortest QRS duration from the 12 leads of the electrocardiogram might be an optimal measurement to predict the response to CRT.

  4. A vector-free ECG interpretation with P, QRS & T waves as unbalanced transitions between stable configurations of the heart electric field during P-R, S-T & T-P segments

    PubMed Central

    2014-01-01

    Since cell membranes are weak sources of electrostatic fields, this ECG interpretation relies on the analogy between cells and electrets. It is here assumed that cell-bound electric fields unite, reach the body surface and the surrounding space and form the thoracic electric field that consists from two concentric structures: the thoracic wall and the heart. If ECG leads measure differences in electric potentials between skin electrodes, they give scalar values that define position of the electric field center along each lead. Repolarised heart muscle acts as a stable positive electric source, while depolarized heart muscle produces much weaker negative electric field. During T-P, P-R and S-T segments electric field is stable, only subtle changes are detectable by skin electrodes. Diastolic electric field forms after ventricular depolarization (T-P segments in the ECG recording). Telediastolic electric field forms after the atria have been depolarized (P-Q segments in the ECG recording). Systolic electric field forms after the ventricular depolarization (S-T segments in the ECG recording). The three ECG waves (P, QRS and T) can then be described as unbalanced transitions of the heart electric field from one stable configuration to the next and in that process the electric field center is temporarily displaced. In the initial phase of QRS, the rapidly diminishing septal electric field makes measured potentials dependent only on positive charges of the corresponding parts of the left and the right heart that lie within the lead axes. If more positive charges are near the "DOWN" electrode than near the "UP" electrode, a Q wave will be seen, otherwise an R wave is expected. Repolarization of the ventricular muscle is dampened by the early septal muscle repolarization that reduces deflection of T waves. Since the "UP" electrode of most leads is near the usually larger left ventricle muscle, T waves are in these leads positive, although of smaller amplitude and longer

  5. Fragmented QRS and mortality in patients undergoing percutaneous intervention for ST-elevation myocardial infarction: Systematic review and meta-analysis.

    PubMed

    Kanjanahattakij, Napatt; Rattanawong, Pattara; Riangwiwat, Tanawan; Prasitlumkum, Narut; Limpruttidham, Nath; Chongsathidkiet, Pakawat; Vutthikraivit, Wasawat; Crossey, Erin

    2018-06-22

    Fragmented QRS reflects disturbances in the myocardium predisposing the heart to ventricular tachyarrhythmias. Recent studies suggest that fragmented QRS (fQRS) is associated with mortality in ST-elevation myocardial infarction (STEMI) patients who underwent percutaneous coronary intervention (PCI). However, a systematic review and meta-analysis of the literature has not been done. We assessed the association between fQRS and overall mortality in STEMI patients who subsequently underwent PCI by a systematic review and meta-analysis. We comprehensively searched the databases of MEDLINE and EMBASE from inception to September 2017. Studies included in our analysis were published cohort (prospective or retrospective) and case-control studies that compared overall mortality among STEMI patient with and without fQRS who underwent PCI. Data from each study were combined using the random-effects, generic inverse variance method of DerSimonian, and Laird to calculate risk ratios and 95% confidence intervals. Six studies from 2014 to 2017 were included in this meta-analysis involving 2,516 subjects with STEMI who underwent PCI (888 fQRS and 1,628 non-fQRS). Fragmented QRS was associated with overall mortality in STEMI patients who underwent PCI (pooled risk ratio = 3.87; 95% CI 1.96-7.66, I 2  = 43%). Fragmented QRS was associated with increased overall mortality up to threefold. Our study suggests that fQRS could be an important tool for risk assessment in STEMI patients who underwent PCI. © 2018 Wiley Periodicals, Inc.

  6. Fragmented QRS complex is a prognostic marker of microvascular reperfusion and changes in LV function occur in patients with ST elevation myocardial infarction who underwent primary percutaneous coronary intervention.

    PubMed

    Zhang, Ruoxi; Chen, Shuyuan; Zhao, Qi; Sun, Meng; Yu, Bo; Hou, Jingbo

    2017-06-01

    The present study aimed to investigate the in-hospital and long-term prognostic value of fragmented QRS complex (fQRS) for microvascular reperfusion and changes in left ventricular (LV) function in patients with ST elevation myocardial infarction (STEMI) who underwent primary percutaneous coronary intervention (PCI). A total of 216 patients with STEMI undergoing primary PCI were included in the current study. Patients were divided into two groups based on the presence (n=126) or absence (n=90) of fQRS following electrocardiograms (ECGs) on admission. Following primary PCI and follow up, patients were divided into four groups based on new onset, resolution, persistence and absence of fQRS. Major adverse cardiac events were defined to include cardiovascular death, arrhythmia, heart failure, reinfarction and target vessel revascularization. The percentage of patients with heart failure and microvascular reperfusion differed significantly between the fQRS(+) and fQRS(-) groups. Levels of N-terminal pro-brain natriuretic peptide (NT-proBNP), Peak creatine kinase-MB (CK-MB) and Troponin I levels were observed to be significantly higher in the fQRS(+) group compared with the fQRS(-) group. In univariate logistic regression analysis, left ventricular ejection fraction (LVEF), NT-proBNP, Troponin I, Peak CK-MB and microvascular reperfusion were found to be associated with fQRS. Multivariate analysis identified that LVEF, NT-proBNP, Troponin I and microvascular reperfusion may be independent predictors of fQRS. The presence of fQRS was demonstrated to be associated with left ventricular dysfunction at follow up assessments. The presence of fQRS was not only significantly associated with myocardial microvascular reperfusion and left ventricular function, but was also a prognostic marker in STEMI.

  7. Data fusion for QRS complex detection in multi-lead electrocardiogram recordings

    NASA Astrophysics Data System (ADS)

    Ledezma, Carlos A.; Perpiñan, Gilberto; Severeyn, Erika; Altuve, Miguel

    2015-12-01

    Heart diseases are the main cause of death worldwide. The first step in the diagnose of these diseases is the analysis of the electrocardiographic (ECG) signal. In turn, the ECG analysis begins with the detection of the QRS complex, which is the one with the most energy in the cardiac cycle. Numerous methods have been proposed in the bibliography for QRS complex detection, but few authors have analyzed the possibility of taking advantage of the information redundancy present in multiple ECG leads (simultaneously acquired) to produce accurate QRS detection. In our previous work we presented such an approach, proposing various data fusion techniques to combine the detections made by an algorithm on multiple ECG leads. In this paper we present further studies that show the advantages of this multi-lead detection approach, analyzing how many leads are necessary in order to observe an improvement in the detection performance. A well known QRS detection algorithm was used to test the fusion techniques on the St. Petersburg Institute of Cardiological Technics database. Results show improvement in the detection performance with as little as three leads, but the reliability of these results becomes interesting only after using seven or more leads. Results were evaluated using the detection error rate (DER). The multi-lead detection approach allows an improvement from DER = 3:04% to DER = 1:88%. Further works are to be made in order to improve the detection performance by implementing further fusion steps.

  8. Noninvasive fetal QRS detection using an echo state network and dynamic programming.

    PubMed

    Lukoševičius, Mantas; Marozas, Vaidotas

    2014-08-01

    We address a classical fetal QRS detection problem from abdominal ECG recordings with a data-driven statistical machine learning approach. Our goal is to have a powerful, yet conceptually clean, solution. There are two novel key components at the heart of our approach: an echo state recurrent neural network that is trained to indicate fetal QRS complexes, and several increasingly sophisticated versions of statistics-based dynamic programming algorithms, which are derived from and rooted in probability theory. We also employ a standard technique for preprocessing and removing maternal ECG complexes from the signals, but do not take this as the main focus of this work. The proposed approach is quite generic and can be extended to other types of signals and annotations. Open-source code is provided.

  9. High Frequency QRS ECG Accurately Detects Cardiomyopathy

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Arenare, Brian; Poulin, Gregory; Moser, Daniel R.; Delgado, Reynolds

    2005-01-01

    High frequency (HF, 150-250 Hz) analysis over the entire QRS interval of the ECG is more sensitive than conventional ECG for detecting myocardial ischemia. However, the accuracy of HF QRS ECG for detecting cardiomyopathy is unknown. We obtained simultaneous resting conventional and HF QRS 12-lead ECGs in 66 patients with cardiomyopathy (EF = 23.2 plus or minus 6.l%, mean plus or minus SD) and in 66 age- and gender-matched healthy controls using PC-based ECG software recently developed at NASA. The single most accurate ECG parameter for detecting cardiomyopathy was an HF QRS morphological score that takes into consideration the total number and severity of reduced amplitude zones (RAZs) present plus the clustering of RAZs together in contiguous leads. This RAZ score had an area under the receiver operator curve (ROC) of 0.91, and was 88% sensitive, 82% specific and 85% accurate for identifying cardiomyopathy at optimum score cut-off of 140 points. Although conventional ECG parameters such as the QRS and QTc intervals were also significantly longer in patients than controls (P less than 0.001, BBBs excluded), these conventional parameters were less accurate (area under the ROC = 0.77 and 0.77, respectively) than HF QRS morphological parameters for identifying underlying cardiomyopathy. The total amplitude of the HF QRS complexes, as measured by summed root mean square voltages (RMSVs), also differed between patients and controls (33.8 plus or minus 11.5 vs. 41.5 plus or minus 13.6 mV, respectively, P less than 0.003), but this parameter was even less accurate in distinguishing the two groups (area under ROC = 0.67) than the HF QRS morphologic and conventional ECG parameters. Diagnostic accuracy was optimal (86%) when the RAZ score from the HF QRS ECG and the QTc interval from the conventional ECG were used simultaneously with cut-offs of greater than or equal to 40 points and greater than or equal to 445 ms, respectively. In conclusion 12-lead HF QRS ECG employing

  10. Ethnic differences in the association of QRS duration with ejection fraction and outcome in heart failure

    PubMed Central

    Gijsberts, Crystel M; Benson, Lina; Dahlström, Ulf; Sim, David; Yeo, Daniel P S; Ong, Hean Yee; Jaufeerally, Fazlur; Leong, Gerard K T; Ling, Lieng H; Richards, A Mark; de Kleijn, Dominique P V; Lund, Lars H; Lam, Carolyn S P

    2016-01-01

    Background QRS duration (QRSd) criteria for device therapy in heart failure (HF) were derived from predominantly white populations and ethnic differences are poorly understood. Methods We compared the association of QRSd with ejection fraction (EF) and outcomes between 839 Singaporean Asian and 11 221 Swedish white patients with HF having preserved EF (HFPEF)and HF having reduced EF (HFREF) were followed in prospective population-based HF studies. Results Compared with whites, Asian patients with HF were younger (62 vs 74 years, p<0.001), had smaller body size (height 163 vs 171 cm, weight 70 vs 80 kg, both p<0.001) and had more severely impaired EF (EF was <30% in 47% of Asians vs 28% of whites). Overall, unadjusted QRSd was shorter in Asians than whites (101 vs 104 ms, p<0.001). Lower EF was associated with longer QRSd (p<0.001), with a steeper association among Asians than whites (pinteraction<0.001), independent of age, sex and clinical covariates (including body size). Excluding patients with left bundle branch block (LBBB) and adjusting for clinical covariates, QRSd was similar in Asians and whites with HFPEF, but longer in Asians compared with whites with HFREF (p=0.001). Longer QRSd was associated with increased risk of HF hospitalisation or death (absolute 2-year event rate for ≤120 ms was 40% and for >120 ms it was 52%; HR for 10 ms increase of QRSd was 1.04 (1.03 to 1.06), p<0.001), with no interaction by ethnicity. Conclusion We found ethnic differences in the association between EF and QRSd among patients with HF. QRS prolongation was similarly associated with increased risk, but the implications for ethnicity-specific QRSd cut-offs in clinical decision-making require further study. PMID:27402805

  11. [Basic mechanisms of QRS voltage changes on ECG of healthy subjects during the exercise test].

    PubMed

    Saltykova, M M

    2015-01-01

    Electrocardiography is the most commonly used technique for detection stress-induced myocardial ischemia. However, the sensitivity of ECG-criteria is not high. One of the major problem is the difficulty in differentiating ECG changes caused by various factors. The aim of this study was to evaluate the dependence of the QRS voltage changes during exercise on parameters of central hemodynamics, gender particularities and to reveal mechanisms causing these changes. To eliminate the effect of changes in cardiomyocytes transmembrane potentials under the influence of the neurotransmitters of the autonomic nervous system during stepwise increasing exercises and/or due to a lack of ATP results from inadequate myocardial blood flow only healthy subjects not older than 35 years were included in the study (7 men and 7 women) and only periods of ventricular depolarization (QRS complex on the ECG) were included in the analysis. We compared the changes of QRS waves during exercise sessions with two upper and one lower limbs in both men and women. The exercise load was twice bigger in exercise with one leg relative to exercise with two arms. Responses of heart rate and systolic arterial pressure were similar. Amplitude of S-wave in left chest leads significantly increased in both sessions without significant difference between augmentations in the sessions and in groups of men and women. Significant relationship between the S wave augmentation and the peak systolic arterial pressure were revealed. Furthermore, the QRS changes during the exercise with vertical and a horizontal torso position were compared to assess the impact of diastolic arterial pressure and displacement of the diaphragm and heart rotation due to increase of abdominal pressure during the last steps of exercise. The obtained results allow us to exclude the impact of the heart position and size changes, as well as the exercise load on S-wave changes and make a conclusion about the dependence of this parameter on

  12. Robust QRS detection for HRV estimation from compressively sensed ECG measurements for remote health-monitoring systems.

    PubMed

    Pant, Jeevan K; Krishnan, Sridhar

    2018-03-15

    To present a new compressive sensing (CS)-based method for the acquisition of ECG signals and for robust estimation of heart-rate variability (HRV) parameters from compressively sensed measurements with high compression ratio. CS is used in the biosensor to compress the ECG signal. Estimation of the locations of QRS segments is carried out by applying two algorithms on the compressed measurements. The first algorithm reconstructs the ECG signal by enforcing a block-sparse structure on the first-order difference of the signal, so the transient QRS segments are significantly emphasized on the first-order difference of the signal. Multiple block-divisions of the signals are carried out with various block lengths, and multiple reconstructed signals are combined to enhance the robustness of the localization of the QRS segments. The second algorithm removes errors in the locations of QRS segments by applying low-pass filtering and morphological operations. The proposed CS-based method is found to be effective for the reconstruction of ECG signals by enforcing transient QRS structures on the first-order difference of the signal. It is demonstrated to be robust not only to high compression ratio but also to various artefacts present in ECG signals acquired by using on-body wireless sensors. HRV parameters computed by using the QRS locations estimated from the signals reconstructed with a compression ratio as high as 90% are comparable with that computed by using QRS locations estimated by using the Pan-Tompkins algorithm. The proposed method is useful for the realization of long-term HRV monitoring systems by using CS-based low-power wireless on-body biosensors.

  13. Distribution and determinants of QRS rotation of black and white persons in the general population.

    PubMed

    Prineas, Ronald J; Zhang, Zhu-Ming; Stevens, Cladd E; Soliman, Elsayed Z

    The prevalence and determinants of QRS transition zones are not well established. We examined the distributions of Normal, clockwise (CW) and counterclockwise (CCW)) QRS transition zones and their relations to disease, body size and demographics in 4624 black and white men and women free of cardiovascular disease and major ECG abnormalities enrolled in the NHANES-III survey. CW transition zones were least observed (6.2%) and CCW were most prevalent (60.1%) with Normal in an intermediate position (33.7%). In multivariable logistic regression analysis, the adjusted, significant predictors for CCW compared to Normal were a greater proportion of blacks and women, fewer thin people (BMI<20, thin), a greater ratio of chest depth to chest width, and an LVMass index <80g. By contrast, CW persons were older, had larger QRS/T angles, smaller ratio of chest depth to chest width, had a greater proportion of subjects with low voltage QRS, more pulmonary disease, a greater proportion with high heart rates, shorter QRS duration and were more obese (BMI≥30). Normal rather than being the most prevalent transition zone was intermediate in frequency between the most frequently encountered CCW and the least frequently encountered transition zone CW. Differences in the predictors of CW and CCW exist. This requires further investigation to examine how far these differences explain the differences in the published prognostic differences between CW and CCW. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Potential role of biventricular pacing beyond advanced systolic heart failure.

    PubMed

    Fang, Fang; Sanderson, John E; Yu, Cheuk-Man

    2013-01-01

    Cardiac resynchronization therapy (CRT) is an effective therapy for advanced heart failure (HF) patients. The indications are well defined in recent guidelines and broadly indicate that CRT is suitable for chronic HF patients with left ventricular ejection fraction (EF) ≤35% and in NYHA class III or IV (Class I), and those with prolonged QRS duration ≥120 ms with left bundle branch block (LBBB) QRS morphology, or QRS duration ≥150 ms irrespective of QRS morphology (Class IIa). For patients with NYHA class II symptoms, CRT is recommended for patients with EF ≤30% and QRS duration ≥130 ms with LBBB QRS morphology (Class I, level of evidence: A), or QRS duration ≥150 ms irrespective of QRS morphology (Class IIa, level of evidence: A). However, CRT may benefit additional patients outside these criteria. In this review, we summarize the role of CRT in some subgroups, including patients with mild and moderate HF, upgrading to CRT from right ventricular (RV) pacing, bradycardia patients with routine pacing indications, congenital heart disease and specific cardiomyopathies. It is possible that CRT can give symptomatic and mortality benefits in some of these subgroups in the future and further clinical trials are warranted.  

  15. Aviation System Analysis Capability (ASAC) Quick Response System (QRS) Test Report

    NASA Technical Reports Server (NTRS)

    Roberts, Eileen; Villani, James A.; Ritter, Paul

    1997-01-01

    This document is the Aviation System Analysis Capability (ASAC) Quick Response System (QRS) Test Report. The purpose of this document is to present the results of the QRS unit and system tests in support of the ASAC QRS development effort. This document contains an overview of the project background and scope, defines the QRS system and presents the additions made to the QRS this year, explains the assumptions, constraints, and approach used to conduct QRS Unit and System Testing, and presents the schedule used to perform QRS Testing. The document also presents an overview of the Logistics Management Institute (LMI) Test Facility and testing environment and summarizes the QRS Unit and System Test effort and results.

  16. Accuracy of computer-calculated and manual QRS duration assessments: Clinical implications to select candidates for cardiac resynchronization therapy.

    PubMed

    De Pooter, Jan; El Haddad, Milad; Stroobandt, Roland; De Buyzere, Marc; Timmermans, Frank

    2017-06-01

    QRS duration (QRSD) plays a key role in the field of cardiac resynchronization therapy (CRT). Computer-calculated QRSD assessments are widely used, however inter-manufacturer differences have not been investigated in CRT candidates. QRSD was assessed in 377 digitally stored ECGs: 139 narrow QRS, 140 LBBB and 98 ventricular paced ECGs. Manual QRSD was measured as global QRSD, using digital calipers, by two independent observers. Computer-calculated QRSD was assessed by Marquette 12SL (GE Healthcare, Waukesha, WI, USA) and SEMA3 (Schiller, Baar, Switzerland). Inter-manufacturer differences of computer-calculated QRSD assessments vary among different QRS morphologies: narrow QRSD: 4 [2-9] ms (median [IQR]), p=0.010; LBBB QRSD: 7 [2-10] ms, p=0.003 and paced QRSD: 13 [6-18] ms, p=0.007. Interobserver differences of manual QRSD assessments measured: narrow QRSD: 4 [2-6] ms, p=non-significant; LBBB QRSD: 6 [3-12] ms, p=0.006; paced QRSD: 8 [4-18] ms, p=0.001. In LBBB ECGs, intraclass correlation coefficients (ICCs) were comparable for inter-manufacturer and interobserver agreement (ICC 0.830 versus 0.837). When assessing paced QRSD, manual measurements showed higher ICC compared to inter-manufacturer agreement (ICC 0.902 versus 0.776). Using guideline cutoffs of 130ms, up to 15% of the LBBB ECGs would be misclassified as <130ms or ≥130ms by at least one method. Using a cutoff of 150ms, this number increases to 33% of ECGs being misclassified. However, by combining LBBB-morphology and QRSD, the number of misclassified ECGs can be decreased by half. Inter-manufacturer differences in computer-calculated QRSD assessments are significant and may compromise adequate selection of individual CRT candidates when using QRSD as sole parameter. Paced QRSD should preferentially be assessed by manual QRSD measurements. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. A lightweight QRS detector for single lead ECG signals using a max-min difference algorithm.

    PubMed

    Pandit, Diptangshu; Zhang, Li; Liu, Chengyu; Chattopadhyay, Samiran; Aslam, Nauman; Lim, Chee Peng

    2017-06-01

    Detection of the R-peak pertaining to the QRS complex of an ECG signal plays an important role for the diagnosis of a patient's heart condition. To accurately identify the QRS locations from the acquired raw ECG signals, we need to handle a number of challenges, which include noise, baseline wander, varying peak amplitudes, and signal abnormality. This research aims to address these challenges by developing an efficient lightweight algorithm for QRS (i.e., R-peak) detection from raw ECG signals. A lightweight real-time sliding window-based Max-Min Difference (MMD) algorithm for QRS detection from Lead II ECG signals is proposed. Targeting to achieve the best trade-off between computational efficiency and detection accuracy, the proposed algorithm consists of five key steps for QRS detection, namely, baseline correction, MMD curve generation, dynamic threshold computation, R-peak detection, and error correction. Five annotated databases from Physionet are used for evaluating the proposed algorithm in R-peak detection. Integrated with a feature extraction technique and a neural network classifier, the proposed ORS detection algorithm has also been extended to undertake normal and abnormal heartbeat detection from ECG signals. The proposed algorithm exhibits a high degree of robustness in QRS detection and achieves an average sensitivity of 99.62% and an average positive predictivity of 99.67%. Its performance compares favorably with those from the existing state-of-the-art models reported in the literature. In regards to normal and abnormal heartbeat detection, the proposed QRS detection algorithm in combination with the feature extraction technique and neural network classifier achieves an overall accuracy rate of 93.44% based on an empirical evaluation using the MIT-BIH Arrhythmia data set with 10-fold cross validation. In comparison with other related studies, the proposed algorithm offers a lightweight adaptive alternative for R-peak detection with good

  18. Ethnic differences in the association of QRS duration with ejection fraction and outcome in heart failure.

    PubMed

    Gijsberts, Crystel M; Benson, Lina; Dahlström, Ulf; Sim, David; Yeo, Daniel P S; Ong, Hean Yee; Jaufeerally, Fazlur; Leong, Gerard K T; Ling, Lieng H; Richards, A Mark; de Kleijn, Dominique P V; Lund, Lars H; Lam, Carolyn S P

    2016-09-15

    QRS duration (QRSd) criteria for device therapy in heart failure (HF) were derived from predominantly white populations and ethnic differences are poorly understood. We compared the association of QRSd with ejection fraction (EF) and outcomes between 839 Singaporean Asian and 11 221 Swedish white patients with HF having preserved EF (HFPEF)and HF having reduced EF (HFREF) were followed in prospective population-based HF studies. Compared with whites, Asian patients with HF were younger (62 vs 74 years, p<0.001), had smaller body size (height 163 vs 171 cm, weight 70 vs 80 kg, both p<0.001) and had more severely impaired EF (EF was <30% in 47% of Asians vs 28% of whites). Overall, unadjusted QRSd was shorter in Asians than whites (101 vs 104 ms, p<0.001). Lower EF was associated with longer QRSd (p<0.001), with a steeper association among Asians than whites (pinteraction<0.001), independent of age, sex and clinical covariates (including body size). Excluding patients with left bundle branch block (LBBB) and adjusting for clinical covariates, QRSd was similar in Asians and whites with HFPEF, but longer in Asians compared with whites with HFREF (p=0.001). Longer QRSd was associated with increased risk of HF hospitalisation or death (absolute 2-year event rate for ≤120 ms was 40% and for >120 ms it was 52%; HR for 10 ms increase of QRSd was 1.04 (1.03 to 1.06), p<0.001), with no interaction by ethnicity. We found ethnic differences in the association between EF and QRSd among patients with HF. QRS prolongation was similarly associated with increased risk, but the implications for ethnicity-specific QRSd cut-offs in clinical decision-making require further study. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Mobile/android application for QRS detection using zero cross method

    NASA Astrophysics Data System (ADS)

    Rizqyawan, M. I.; Simbolon, A. I.; Suhendra, M. A.; Amri, M. F.; Kusumandari, D. E.

    2018-03-01

    In automatic ECG signal processing, one of the main topics of research is QRS complex detection. Detecting correct QRS complex or R peak is important since it is used to measure several other ECG metrics. One of the robust methods for QRS detection is Zero Cross method. This method uses an addition of high-frequency signal and zero crossing count to detect QRS complex which has a low-frequency oscillation. This paper presents an application of QRS detection using Zero Cross algorithm in the Android-based system. The performance of the algorithm in the mobile environment is measured. The result shows that this method is suitable for real-time QRS detection in a mobile application.

  20. Fragmented QRS in patients with systemic lupus erythematosus.

    PubMed

    Demır, Kenan; Avcı, Ahmet; Yılmaz, Sema; Demır, Tarık; Ersecgın, Ahmet; Altunkeser, Bulent Behlul

    2014-08-01

    Systemic lupus erythematosus (SLE) is a systemic autoimmune disease with a variety of clinical features. Cardiac involvement is present in more than half of the patients with SLE. Fragmentation of QRS (fQRS) is presumed marker of cardiovascular risk and has not been previously evaluated in SLE. A total of 56 women previously diagnosed with SLE were recruited. In addition, a control group consisting of 51 healthy people was formed. QRS complexes were also evaluated in terms of fragmentations. All patients with SLE and control subjects underwent transthoracic echocardiographic examination. Erythrocyte sedimentation rate and C-reactive protein levels were also obtained. Frequency of fQRS was higher in patients with SLE (41% vs. 21%, p = 0.03). Left ventricular posterior wall thickness and mass index were higher in the patients with SLE. CRP levels and age were significantly higher, and disease duration was significantly longer in the fQRS(+) group (p = 0.02, 0.01, and 0.006, respectively). A careful cardiovascular evaluation and follow-up is essential to continuously improve survival in SLE. For this purpose, fQRS may be used for the early detection in patients with SLE.

  1. Prognostic Estimation of Advanced Heart Failure With Low Left Ventricular Ejection Fraction and Wide QRS Interval.

    PubMed

    Oh, Changmyung; Chang, Hyuk-Jae; Sung, Ji Min; Kim, Ji Ye; Yang, Wooin; Shim, Jiyoung; Kang, Seok-Min; Ha, Jongwon; Rim, Se-Joong; Chung, Namsik

    2012-10-01

    Cardiac resynchronization therapy (CRT) has been known to improve the outcome of advanced heart failure (HF) but is still underutilized in clinical practice. We investigated the prognosis of patients with advanced HF who were suitable for CRT but were treated with conventional strategies. We also developed a risk model to predict mortality to improve the facilitation of CRT. Patients with symptomatic HF with left ventricular ejection fraction ≤35% and QRS interval >120 ms were consecutively enrolled at cardiovascular hospital. After excluding those patients who had received device therapy, 239 patients (160 males, mean 67±11 years) were eventually recruited. During a follow-up of 308±236 days, 56 (23%) patients died. Prior stroke, heart rate >90 bpm, serum Na ≤135 mEq/L, and serum creatinine ≥1.5 mg/dL were identified as independent factors using Cox proportional hazards regression. Based on the risk model, points were assigned to each of the risk factors proportional to the regression coefficient, and patients were stratified into three risk groups: low- (0), intermediate-(1-5), and high-risk (>5 points). The 2-year mortality rates of each risk group were 5, 31, and 64 percent, respectively. The C statistic of the risk model was 0.78, and the model was validated in a cohort from a different institution where the C statistic was 0.80. The mortality of patients with advanced HF who were managed conventionally was effectively stratified using a risk model. It may be useful for clinicians to be more proactive about adopting CRT to improve patient prognosis.

  2. Counterclockwise and Clockwise Rotation of QRS Transitional Zone: Prospective Correlates of Change and Time-Varying Associations With Cardiovascular Outcomes.

    PubMed

    Patel, Siddharth; Kwak, Lucia; Agarwal, Sunil K; Tereshchenko, Larisa G; Coresh, Josef; Soliman, Elsayed Z; Matsushita, Kunihiro

    2017-11-03

    A few studies have recently reported clockwise and counterclockwise rotations of QRS transition zone as predictors of mortality. However, their prospective correlates and associations with individual cardiovascular disease (CVD) outcomes are yet to be investigated. Among 13 567 ARIC (Atherosclerosis Risk in Communities) study participants aged 45 to 64 years, we studied key correlates of changes in the status of clockwise and counterclockwise rotation over time as well as the association of rotation status with incidence of coronary heart disease (2408 events), heart failure (2196 events), stroke (991 events), composite CVD (4124 events), 898 CVD deaths, and 3469 non-CVD deaths over 23 years of follow-up. At baseline, counterclockwise rotation was most prevalent (52.9%), followed by no (40.5%) and clockwise (6.6%) rotation. Of patients with no rotation, 57.9% experienced counterclockwise or clockwise rotation during follow-up, with diabetes mellitus and black race significantly predicting clockwise and counterclockwise conversion, respectively. Clockwise rotation was significantly associated with higher risk of heart failure (hazard ratio, 1.20; 95% confidence interval [CI], 1.02-1.41) and non-CVD death (hazard ratio, 1.28; 95% CI, 1.12-1.46) after adjusting for potential confounders including other ECG parameters. On the contrary, counterclockwise rotation was significantly related to lower risk of composite CVD (hazard ratio, 0.93; 95% CI, 0.87-0.99]), CVD mortality (hazard ratio, 0.76; 95% CI, 0.65-0.88), and non-CVD deaths (hazard ratio, 0.92; 95% CI, 0.85-0.99 [borderline significance with heart failure]). Counterclockwise rotation, the most prevalent QRS transition zone pattern, demonstrated the lowest risk of CVD and mortality, whereas clockwise rotation was associated with the highest risk of heart failure and non-CVD mortality. These results have implications on how to interpret QRS transition zone rotation when ECG was recorded. © 2017 The Authors

  3. Value of the Qrs-T Angle in Predicting the Induction of Ventricular Tachyarrhythmias in Patients with Chagas Disease.

    PubMed

    Zampa, Hugo Bizetto; Moreira, Dalmo Ar; Ferreira Filho, Carlos Alberto Brandão; Souza, Charles Rios; Menezes, Camila Caldas; Hirata, Henrique Seichii; Armaganijan, Luciana Vidal

    2014-10-28

    Background: The QRS-T angle correlates with prognosis in patients with heart failure and coronary artery disease, reflected by an increase in mortality proportional to an increase in the difference between the axes of the QRS complex and T wave in the frontal plane. The value of this correlation in patients with Chagas heart disease is currently unknown. Objective: Determine the correlation of the QRS-T angle and the risk of induction of ventricular tachycardia / ventricular fibrillation (VT / VF) during electrophysiological study (EPS) in patients with Chagas disease. Methods: Case-control study at a tertiary center. Patients without induction of VT / VF on EPS were used as controls. The QRS-T angle was categorized as normal (0-105º), borderline (105-135º) or abnormal (135-180º). Differences between groups for continuous variables were analyzed with the t test or Mann-Whitney test, and for categorical variables with Fisher's exact test. P values < 0.05 were considered significant. Results: Of 116 patients undergoing EPS, 37.9% were excluded due to incomplete information / inactive records or due to the impossibility to correctly calculate the QRS-T angle (presence of left bundle branch block and atrial fibrillation). Of 72 patients included in the study, 31 induced VT / VF on EPS. Of these, the QRS-T angle was normal in 41.9%, borderline in 12.9% and abnormal in 45.2%. Among patients without induction of VT / VF on EPS, the QRS-T angle was normal in 63.4%, borderline in 14.6% and abnormal in 17.1% (p = 0.04). When compared with patients with normal QRS-T angle, those with abnormal angle had a fourfold higher risk of inducing ventricular tachycardia / ventricular fibrillation on EPS [odds ratio (OR) 4; confidence interval (CI) 1.298-12.325; p = 0.028]. After adjustment for other variables such as age, ejection fraction (EF) and QRS size, there was a trend for the abnormal QRS-T angle to identify patients with increased risk of inducing VT / VF during EPS (OR 3

  4. High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P less than 0.00l). Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

  5. High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

    NASA Technical Reports Server (NTRS)

    Rahman, Atiar

    2006-01-01

    Background: Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). Methods and Results: 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P<0.001). Conclusions: Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

  6. QRS Detection Algorithm for Telehealth Electrocardiogram Recordings.

    PubMed

    Khamis, Heba; Weiss, Robert; Xie, Yang; Chang, Chan-Wei; Lovell, Nigel H; Redmond, Stephen J

    2016-07-01

    QRS detection algorithms are needed to analyze electrocardiogram (ECG) recordings generated in telehealth environments. However, the numerous published QRS detectors focus on clean clinical data. Here, a "UNSW" QRS detection algorithm is described that is suitable for clinical ECG and also poorer quality telehealth ECG. The UNSW algorithm generates a feature signal containing information about ECG amplitude and derivative, which is filtered according to its frequency content and an adaptive threshold is applied. The algorithm was tested on clinical and telehealth ECG and the QRS detection performance is compared to the Pan-Tompkins (PT) and Gutiérrez-Rivas (GR) algorithm. For the MIT-BIH Arrhythmia database (virtually artifact free, clinical ECG), the overall sensitivity (Se) and positive predictivity (+P) of the UNSW algorithm was >99%, which was comparable to PT and GR. When applied to the MIT-BIH noise stress test database (clinical ECG with added calibrated noise) after artifact masking, all three algorithms had overall Se >99%, and the UNSW algorithm had higher +P (98%, p < 0.05) than PT and GR. For 250 telehealth ECG records (unsupervised recordings; dry metal electrodes), the UNSW algorithm had 98% Se and 95% +P which was superior to PT (+P: p < 0.001) and GR (Se and +P: p < 0.001). This is the first study to describe a QRS detection algorithm for telehealth data and evaluate it on clinical and telehealth ECG with superior results to published algorithms. The UNSW algorithm could be used to manage increasing telehealth ECG analysis workloads.

  7. Diagnostic value of QRS and S wave variation in patients with suspicion of acute pulmonary embolism.

    PubMed

    Çağdaş, Metin; Karakoyun, Süleyman; Rencüzoğulları, İbrahim; Karabağ, Yavuz; Artaç, İnanç; İliş, Doğan; Hamideyin, Şerif; Karayol, Sibel; Çiftçi, Handan; Çınar, Tufan

    2018-03-29

    This study aimed to investigate the diagnostic value of QRS and S wave variation in patients admitted to the emergency department with suspicion of acute pulmonary embolism (APE). Computerized tomographic pulmonary angiography (CTPA) was performed in 118 consecutive patients to evaluate patients with suspected APE, and 106 subjects with appropriate electrocardiogram and CT images constituted the study population. Using CTPA, APE was diagnosed in 48.1% (n:51) of the study population. The comparison of patients with APE and those without APE revealed that increased heart rate, right axis deviation of QRS axis, complete or incomplete right bundle branch block, prominent S wave in lead D1, increased QRS duration, percentage of QRS (9,8[4,8-19,0] vs 3,8[2,7-71]; p<0,001), S wave variation (22,3[9,6-31,9] vs 4,8 [2-8]; p<0,001) and ΔS wave amplitude (1.1[0.5-1.5] vs 0.2[0.1-0.5]; p<0.001) were significantly associated with APE, but no relationship was detected with respect to the presence of atrial arrhythmias, clockwise rotation of the horizontal axis, fragmentation, ST segment deviation, T wave inversion, and S1Q3T3 and S1S2S3 patterns. The percentage of S wave variation (OR: 1072 per 1% increase, 95% CI:1011-1137) was found to be an independent predictor of APE. ΔS wave amplitude>0.5mm predicted APE with a sensitivity of 72.6% and a specificity of 74.6% (AUC:0.805, 95% CI: 0.717-0.876; p<0.001). The present study demonstrated that QRS and S wave variation could be useful electrocardiographic signs for the diagnosis of APE. Copyright © 2018. Published by Elsevier Inc.

  8. Automatic QRS complex detection using two-level convolutional neural network.

    PubMed

    Xiang, Yande; Lin, Zhitao; Meng, Jianyi

    2018-01-29

    The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especially in the transform domains. In addition, fixed features and parameters are not suitable for detecting various kinds of QRS complexes under different circumstances. In this study, based on 1-D convolutional neural network (CNN), an accurate method for QRS complex detection is proposed. The CNN consists of object-level and part-level CNNs for extracting different grained ECG morphological features automatically. All the extracted morphological features are used by multi-layer perceptron (MLP) for QRS complex detection. Additionally, a simple ECG signal preprocessing technique which only contains difference operation in temporal domain is adopted. Based on the MIT-BIH arrhythmia (MIT-BIH-AR) database, the proposed detection method achieves overall sensitivity Sen = 99.77%, positive predictivity rate PPR = 99.91%, and detection error rate DER = 0.32%. In addition, the performance variation is performed according to different signal-to-noise ratio (SNR) values. An automatic QRS detection method using two-level 1-D CNN and simple signal preprocessing technique is proposed for QRS complex detection. Compared with the state-of-the-art QRS complex detection approaches, experimental results show that the proposed method acquires comparable accuracy.

  9. [A research on real-time ventricular QRS classification methods for single-chip-microcomputers].

    PubMed

    Peng, L; Yang, Z; Li, L; Chen, H; Chen, E; Lin, J

    1997-05-01

    Ventricular QRS classification is key technique of ventricular arrhythmias detection in single-chip-microcomputer based dynamic electrocardiogram real-time analyser. This paper adopts morphological feature vector including QRS amplitude, interval information to reveal QRS morphology. After studying the distribution of QRS morphology feature vector of MIT/BIH DB ventricular arrhythmia files, we use morphological feature vector cluster to classify multi-morphology QRS. Based on the method, morphological feature parameters changing method which is suitable to catch occasional ventricular arrhythmias is presented. Clinical experiments verify missed ventricular arrhythmia is less than 1% by this method.

  10. Colorado Qualistar. QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Colorado's Qualistar prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  11. Cardiac-resynchronization therapy for mild-to-moderate heart failure.

    PubMed

    Tang, Anthony S L; Wells, George A; Talajic, Mario; Arnold, Malcolm O; Sheldon, Robert; Connolly, Stuart; Hohnloser, Stefan H; Nichol, Graham; Birnie, David H; Sapp, John L; Yee, Raymond; Healey, Jeffrey S; Rouleau, Jean L

    2010-12-16

    Cardiac-resynchronization therapy (CRT) benefits patients with left ventricular systolic dysfunction and a wide QRS complex. Most of these patients are candidates for an implantable cardioverter-defibrillator (ICD). We evaluated whether adding CRT to an ICD and optimal medical therapy might reduce mortality and morbidity among such patients. We randomly assigned patients with New York Heart Association (NYHA) class II or III heart failure, a left ventricular ejection fraction of 30% or less, and an intrinsic QRS duration of 120 msec or more or a paced QRS duration of 200 msec or more to receive either an ICD alone or an ICD plus CRT. The primary outcome was death from any cause or hospitalization for heart failure. We followed 1798 patients for a mean of 40 months. The primary outcome occurred in 297 of 894 patients (33.2%) in the ICD-CRT group and 364 of 904 patients (40.3%) in the ICD group (hazard ratio in the ICD-CRT group, 0.75; 95% confidence interval [CI], 0.64 to 0.87; P<0.001). In the ICD-CRT group, 186 patients died, as compared with 236 in the ICD group (hazard ratio, 0.75; 95% CI, 0.62 to 0.91; P = 0.003), and 174 patients were hospitalized for heart failure, as compared with 236 in the ICD group (hazard ratio, 0.68; 95% CI, 0.56 to 0.83; P<0.001). However, at 30 days after device implantation, adverse events had occurred in 124 patients in the ICD-CRT group, as compared with 58 in the ICD group (P<0.001). Among patients with NYHA class II or III heart failure, a wide QRS complex, and left ventricular systolic dysfunction, the addition of CRT to an ICD reduced rates of death and hospitalization for heart failure. This improvement was accompanied by more adverse events. (Funded by the Canadian Institutes of Health Research and Medtronic of Canada; ClinicalTrials.gov number, NCT00251251.).

  12. A deep learning approach for fetal QRS complex detection.

    PubMed

    Zhong, Wei; Liao, Lijuan; Guo, Xuemei; Wang, Guoli

    2018-04-20

    Non-invasive foetal electrocardiography (NI-FECG) has the potential to provide more additional clinical information for detecting and diagnosing fetal diseases. We propose and demonstrate a deep learning approach for fetal QRS complex detection from raw NI-FECG signals by using a convolutional neural network (CNN) model. The main objective is to investigate whether reliable fetal QRS complex detection performance can still be obtained from features of single-channel NI-FECG signals, without canceling maternal ECG (MECG) signals. A deep learning method is proposed for recognizing fetal QRS complexes. Firstly, we collect data from set-a of the PhysioNet/computing in Cardiology Challenge database. The sample entropy method is used for signal quality assessment. Part of the bad quality signals is excluded in the further analysis. Secondly, in the proposed method, the features of raw NI-FECG signals are normalized before they are fed to a CNN classifier to perform fetal QRS complex detection. We use precision, recall, F-measure and accuracy as the evaluation metrics to assess the performance of fetal QRS complex detection. The proposed deep learning method can achieve relatively high precision (75.33%), recall (80.54%), and F-measure scores (77.85%) compared with three other well-known pattern classification methods, namely KNN, naive Bayes and SVM. the proposed deep learning method can attain reliable fetal QRS complex detection performance from the raw NI-FECG signals without canceling MECG signals. In addition, the influence of different activation functions and signal quality assessment on classification performance are evaluated, and results show that Relu outperforms the Sigmoid and Tanh on this particular task, and better classification performance is obtained with the signal quality assessment step in this study.

  13. The electrical heart axis and ST events in fetal monitoring: A post-hoc analysis following a multicentre randomised controlled trial.

    PubMed

    Vullings, Rik; Verdurmen, Kim M J; Hulsenboom, Alexandra D J; Scheffer, Stephanie; de Lau, Hinke; Kwee, Anneke; Wijn, Pieter F F; Amer-Wåhlin, Isis; van Laar, Judith O E H; Oei, S Guid

    2017-01-01

    Reducing perinatal morbidity and mortality is one of the major challenges in modern health care. Analysing the ST segment of the fetal electrocardiogram was thought to be the breakthrough in fetal monitoring during labour. However, its implementation in clinical practice yields many false alarms and ST monitoring is highly dependent on cardiotocogram assessment, limiting its value for the prediction of fetal distress during labour. This study aims to evaluate the relation between physiological variations in the orientation of the fetal electrical heart axis and the occurrence of ST events. A post-hoc analysis was performed following a multicentre randomised controlled trial, including 1097 patients from two participating centres. All women were monitored with ST analysis during labour. Cases of fetal metabolic acidosis, poor signal quality, missing blood gas analysis, and congenital heart disease were excluded. The orientation of the fetal electrical heart axis affects the height of the initial T/QRS baseline, and therefore the incidence of ST events. We grouped tracings with the same initial baseline T/QRS value. We depicted the number of ST events as a function of the initial baseline T/QRS value with a linear regression model. A significant increment of ST events was observed with increasing height of the initial T/QRS baseline, irrespective of the fetal condition; correlation coefficient 0.63, p<0.001. The most frequent T/QRS baseline is 0.12. The orientation of the fetal electrical heart axis and accordingly the height of the initial T/QRS baseline should be taken into account in fetal monitoring with ST analysis.

  14. Total Mortality, Major Adverse Cardiac Events, and Echocardiographic-Derived Cardiac Parameters with Fragmented QRS Complex.

    PubMed

    Gong, Bojun; Li, Zicheng

    2016-07-01

    Fragmented QRS complex (fQRS), an easily evaluated noninvasive electrocardiographic parameter, is associated with worse outcomes in patients with several cardiovascular conditions. The presence of fQRS on ECG may be an indicator of myocardial damage in patients with coronary artery disease (CAD). In this article, we performed a meta-analysis in order to characterize the presence of fQRS on ECG in patients with CAD. We searched English-language randomized controlled trials involving fQRS on ECG in patients with CAD (n = 3279 patients, 12 trials). Two reviewers independently extracted data. Data on LVEF, LVESD, LVEDD, LVESV, LVEDV, total mortality, stroke, and MACE were collected. fQRS was performed a comparison with non-fQRS, calculating pooled relatives risk (RRs) and weighted mean difference (WMD), and associated 95% confidence intervals (CIs). fQRS was associated with significant increased WMD of LVEDD (WMD, 2.26; 95%CI, 0.92 to 0.36, P = 0.0009), LVESD (WMD, 2.71; 95%CI, 1.23 to 4.19, P = 0.0003), LVEDV (WMD, 31.37; 95%CI, 24.82 to 37.92, P < 0.00001), and LVESV (WMD, 28.45; 95%CI, 22.92 to 33.98, P < 0.00001). As compared to non-fQRS, fQRS increased risk of total mortality (RR, 3.09; 95%CI, 1.76 to 5.44, P < 0.0001) and MACE (RR, 2.85; 95%CI, 1.98 to 4.09, P < 0.00001) in patients with CAD. However, a decreased trend was observed for LVEF (WMD, -3.59; 95%CI, -7.05 to -0.12, P = 0.04). For the incidence of stoke, there was no difference between fQRS and non-fQRS group. Our findings indicate that fQRS is a valuable factor to predict total mortality and MACE in patients with CAD. © 2015 Wiley Periodicals, Inc.

  15. Pennsylvania Keystone STARS: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Pennsylvania's Keystone STARS prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  16. Illinois Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Illinois' Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  17. Minnesota Parent Aware: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Minnesota's Parent Aware prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  18. Combined assessment of myocardial damage and electrical disturbance in chronic heart failure

    PubMed Central

    Kadowaki, Shinpei; Watanabe, Tetsu; Otaki, Yoichiro; Narumi, Taro; Honda, Yuki; Takahashi, Hiroki; Arimoto, Takanori; Shishido, Tetsuro; Miyamoto, Takuya; Kubota, Isao

    2017-01-01

    AIM To investigate feasibility of combined assessment of biochemical and electrophysiological myocardial impairment markers risk-stratifying patients with chronic heart failure (CHF). METHODS Serum levels of heart-type fatty acid binding protein (H-FABP) as a marker of ongoing myocardial damage and QRS duration on electrocardiogram were measured at admission in 322 consecutive patients with CHF. A prolonged QRS duration was defined as 120 ms or longer. The cut-off value for H-FABP level (4.5 ng/mL) was determined from a previous study. Patients were prospectively followed during a median follow up period of 534 d. The primary endpoint was cardiac deaths and rehospitalization for worsening CHF. RESULTS There were 117 primary events, including 27 cardiac deaths and 90 rehospitalizations. Patients were stratified into four groups according to H-FABP level and QRS duration (≥ 120 ms). Multivariate analysis demonstrated that high H-FABP levels [hazard ratio (HR) = 1.745, P = 0.021] and QRS prolongation (HR 1.612, P = 0.0258) were independent predictors of cardiac events. Kaplan-Meier analysis demonstrated that the combination of high H-FABP levels and QRS prolongation could be used to reliably stratify patients at high risk for cardiac events (log rank test P < 0.0001). CONCLUSION Combined assessment of myocardial damage and electrical disturbance can be used to risk-stratify patients with CHF. PMID:28603594

  19. The prognostic value of the frontal QRS-T angle is comparable to cardiovascular autonomic neuropathy regarding long-term mortality in people with diabetes. A population based study.

    PubMed

    May, O; Graversen, C B; Johansen, M Ø; Arildsen, H

    2018-06-09

    Cardiovascular autonomic neuropathy (CAN) is a well known prognostic marker in diabetes. A large angle between the QRS- and the T-wave vector (QRS-T angle) in the electrocardiogram (ECG) has recently been introduced as another marker of poor prognosis. To assess and compare the long-term predictive power of the frontal plane QRS-T angle with CAN in people with diabetes. In 1992-93 people with diabetes in the municipality of Horsens, Denmark, were identified by the prescription method andan age and gender stratified sample of 240 individuals with diabetes were randomly selected. The presence of CAN was defined using the heart rate response to Valsalva manoeuvre. The QRS-T angle was read using the method described by Gandhi. In July 2015 vital statistics were obtained fromthe Danish Civil Registration System. 178 individuals accepted to participate in the study, of which 153 (86%) completed the Valsalva manoeuvre and had sinus rhythm. Total observation time was 21.5 (0.18) years, in which 99 (65%) individuals died. An elevated QRS-T angle and the presence of cardiovascular autonomic neuropathy were both found to be significant predictors of death. In Cox regression analyses, adjusting for the effect of gender, age, duration of diabetes, BMI, total-cholesterol, diabetes type, haemoglobin A1c, smoking status, hypertension and previous MI, an independent prognostic value was found for the QRS-T angle as well as the Valsalva ratio. A large QRS-T angle and the presence of cardiovascular autonomic neuropathy are both strong and independent long-term predictors of all-cause mortality in people with diabetes. Copyright © 2018. Published by Elsevier B.V.

  20. Virginia Star Quality Initiative: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Virginia's Star Quality Initiative prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators…

  1. Mississippi Quality Step System: QRS Profile. The Child Care Quality Rating System (QRS)Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Mississippi's Quality Step System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Application…

  2. Cadmium stress assessment based on the electrocardiogram characteristics of zebra fish (Danio rerio): QRS complex could play an important role.

    PubMed

    Xing, Na; Ji, Lizhen; Song, Jie; Ma, Jingchun; Li, Shangge; Ren, Zongming; Xu, Fei; Zhu, Jianping

    2017-10-01

    The electrocardiogram (ECG) of zebra fish (Danio rerio) expresses cardiac features that are similar to humans. Here we use sharp microelectrode measurements to obtain ECG characteristics in adult zebra fish and analyze the effects of cadmium chloride (CdCl 2 ) on the heart. We observe the overall changes of ECG parameters in different treatments (0.1 TU, 0.5 TU and 1.0 TU CdCl 2 ), including P wave, Q wave, R wave, S wave, T wave, PR interval (atrial contraction), QRS complex (ventricular depolarization), ST segment, and QT interval (ventricular repolarization). The trends of the ECG parameters showed some responses to the concentration and exposure time of CdCl 2 , but it was difficult to obtain more information about the useful indicators in water quality assessment depending on tendency analysis alone. A self-organizing map (SOM) showed that P values, R values, and T values were similar; R wave and T wave amplitude were similar; and most important, QRS value was similar to the CdCl 2 stress according to the classified data patterns including CdCl 2 stress (E) and ECG components based on the Ward linkage. It suggested that the duration of QRS complex was related to environmental stress E directly. The specification and evaluation of ECG parameters in Cd 2+ pollution suggested that there is a markedly significant correlation between QRS complex and CdCl 2 stress with the highest r (0.729) and the smallest p (0.002) among all ECG characteristics. In this case, it is concluded that QRS complex can be used as an indicator in the CdCl 2 stress assessment due to the lowest AIC data abased on the linear regression model between the CdCl 2 stress and ECG parameters. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Analysis of the temporal regression of the QRS widening induced by bupivacaine after Intralipid administration. Study in an experimental porcine model.

    PubMed

    Zaballos, M; Sevilla, R; González, J; Callejo, D; de Diego, C; Almendral, J; Quintela, O; Anadón, M J

    2016-01-01

    The principal mechanism of cardiac toxicity of bupivacaine relates to the blockade of myocardial sodium channels, which leads to an increase in the QRS duration. Recently, experimental studies suggest that lipid emulsion is effective in reversing bupivacaine cardiac toxicity. We aimed to evaluate the temporal evolution of the QRS widening induced by bupivacaine with the administration of Intralipid. Twelve pigs were anesthetized with intravenous sodium thiopental 5mg kg(-1) and sevoflurane 1 MAC (2.6%). Femoral artery and vein were canalized for invasive monitoring, analysis of blood gases and determination of bupivacaine levels. After instrumentation and monitoring, a bupivacaine bolus of 4-6 mg kg(-1) was administered in order to induce a 150% increase in QRS duration (defined as the toxic point). The pigs were randomized into two groups of six individuals. Intralipid group (IL) received 1.5 mL kg(-1)of IL over one minute, followed by an infusion of 0.25 mL kg min(-1). Control group (C) received the same volume of a saline solution. The electrocardiographic parameters were recorded, and blood samples were taken after bupivacaine and 1, 5, 10 and 30 minutes after Intralipid/saline administration. Bupivacaine (4.33±0.81 mg/kg in IL group and 4.66±1.15 mg/kg in C group) induced similar electrocardiographic changes in both groups; mean maximal percent increase in QRS interval was 184±62% in IL group, and 230±56% in control group (NS). Lipid administration reversed the QRS widening previously impaired by bupivacaine. After ten minutes of the administration of IL, the mean QRS interval decreased to 132±56% vs. 15±76% relative to the maximum widening induced by bupivacaine, in IL and C group, respectively. Intralipid reversed the lengthening of QRS interval induced by the injection of bupivacaine. Time to normalization of electrocardiographic parameters can last more than 10 minutes. While the phenomena of cardiac toxicity persist, resuscitation measures and

  4. Electrocardiographic signal-averaging during atrial pacing and effect of cycle length on the terminal QRS in patients with and without inducible ventricular tachycardia.

    PubMed

    Kremers, M S; Black, W H; Lange, R; Wells, P J; Solo, M

    1990-11-01

    Electrocardiographic signal-averaging during sinus rhythm (61 to 99 beats/min) and atrial pacing (100 to 171 beats/min) were performed to determine the effect of heart rate on late potentials in 15 patients without (group 1) and 7 patients with (group 2) inducible sustained ventricular tachycardia (VT). In sinus rhythm (79 +/- 12 vs 77 +/- 12 beats/min, difference not significant), the duration of the low-amplitude signal less than 40 microV was longer in group 2 than group 1 (43 +/- 21 vs 26 +/- 8 ms, p = 0.034) and more patients had late potentials (57 vs 7%, p = 0.021), but QRS duration (121 +/- 32 vs 98 +/- 19 ms) and terminal voltage (33 +/- 33 vs 50 +/- 26 ms) were not significantly different. With atrial pacing in group 1 (128 +/- 16 beats/min), 3 patients developed a simultaneous decrease in terminal voltage and an increase in terminal QRS duration consistent with a late potential, but mean total and terminal durations were unchanged. Terminal voltage increased (50 +/- 26 to 59 +/- 40) but not significantly. With atrial pacing in group 2 (119 +/- 12 beats/min) all patients either had a late potential or developed a simultaneous decrease in terminal voltage and an increase in terminal QRS duration (p = 0.001 vs group 1). Root mean square (p = 0.001 vs group 1). Root mean square voltage decreased (33 +/- 23 to 22 +/- 23) and became significantly different from group 1 (p = 0.017). Mean QRS duration, root mean square terminal voltage and low-amplitude terminal QRS duration, however, were unchanged.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Palm Beach Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Palm Beach's Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  6. Maine Quality for ME: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Maine's Quality for ME prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  7. Missouri Quality Rating System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Missouri's Quality Rating System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  8. Miami-Dade Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Miami-Dade's Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  9. Indiana Paths to Quality: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Indiana's Paths to Quality prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  10. Early Changes in QRS Frequency Following Cardiac Resynchronization Predict Hemodynamic Response in Left Bundle Branch Block Patients.

    PubMed

    Niebauer, Mark J; Rickard, John; Tchou, Patrick J; Varma, Niraj

    2016-05-01

    QRS characteristics are the cornerstone of patient selection in cardiac resynchronization therapy (CRT) and the presence of left bundle branch block (LBBB) and baseline QRS ≥150 milliseconds portends a good outcome. We previously showed that baseline QRS frequency analysis adds predictive value to LBBB alone and have hypothesized that a change in frequency characteristics following CRT may produce additional predictive value. We examined the QRS frequency characteristics of 182 LBBB patients before and soon after CRT. Patients were assigned to responder and nonresponder groups. Responders were defined by a decrease in left ventricular end-systolic volume (LVESV) ≥15% following CRT. We analyzed the QRS in ECG leads I, AVF, and V3 before and soon after CRT using the discrete Fourier transform algorithm. The percentage of total QRS power within discrete frequency intervals before and after CRT was calculated. The reduction in lead V3 power <10 Hz was the best indicator of response. Baseline QRS width was similar between the responders and nonresponders (162.2 ± 17.2 milliseconds vs. 158 ± 22.1 milliseconds, respectively; P = 0.180). Responders exhibited a greater reduction in QRS power <10 Hz (-17.0 ± 11.9% vs. -6.6 ± 12.5%; P < 0.001) and a significant AUC (0.743; P < 0.001). A ≥8% decline in QRS power <10 Hz produced the best predictive values (PPV = 84%, NPV = 59%). Importantly, when patients with baseline QRS <150 milliseconds were compared, the AUC improved (0.892, P < 0.001). Successful CRT produces a significant reduction in QRS power below 10 Hz, particularly when baseline QRS <150 milliseconds. These results indicate that QRS frequency changes after CRT provide additional predictive value to QRS alone. © 2016 Wiley Periodicals, Inc.

  11. QT Interval Prolongation and QRS Voltage Reduction in Patients with Liver Cirrhosis.

    PubMed

    Cichoż-Lach, Halina; Tomaszewski, Michał; Kowalik, Agnieszka; Lis, Emilia; Tomaszewski, Andrzej; Lach, Tomasz; Boczkowska, Sylwia; Celiński, Krzysztof

    2015-01-01

    Liver cirrhosis is associated with functional abnormalities of the cardiovascular system with co-existing electrocardiographic (ECG) abnormalities. The aim was to analyze ECG changes in patients with cirrhosis, to evaluate whether alcoholic etiology of cirrhosis and ascites has an impact on ECG changes. The study involved 81 patients with previously untreated alcoholic cirrhosis (64 patients with ascites, classes B and C according to the Child-Pugh classification; and 17 without ascites, categorized as class A); 41 patients with previously untreated cirrhosis due to chronic hepatitis C (HCV--30 patients with ascites, classes B and C; and 11 without ascites, class A); 42 with alcoholic steatohepatitis and 46 with alcoholic steatosis. The control group consisted of 32 healthy volunteers. Twelve-lead ECG recordings were performed and selected parameters were measured. Significantly longer QT and QTc intervals and lower QRS voltage were found in patients with alcoholic and HCV cirrhosis compared to the controls. Significantly lower QRS voltage was found in subjects with ascites than in those without ascites. Removal of ascites significantly increased QRS voltage. In cirrhosis, irrespective of etiology, ECG changes involved prolonged QT and QTc intervals and reduced QRS voltage. Prolonged QT and QTc intervals were not related to the severity of cirrhosis or to the presence of ascites. However, low QRS voltage was associated with the presence of ascites. Removal of ascites reverses low QRS voltage.

  12. Relationship between a fragmented QRS and microalbuminuria in patients with type 2 diabetes mellitus.

    PubMed

    Cetin, Sukru; Yıldız, Suleyman Sezai; Mazı, Emrah Erkan; Keskin, Kudret; Cetinkal, Gokhan; Gurdal, Ahmet; Karabay, Umut; Orta Kilickesmez, Kadriye

    2017-11-01

    Microalbuminuria (MAU), a complication of diabetes, is closely related to cardiovascular events. A fragmented QRS (fQRS) in the electrocardiogram (ECG) was found to be strongly associated to cardiovascular morbidity and mortality. The aim of this study was to assess the association between a fQRS and MAU in patients with type 2 diabetes mellitus (T2DM). One hundred and twenty-seven patients (mean age, 50.49 years; 44.01% male) with T2DM of at least six months duration and at least two urine albumin/creatinine ratios (ACRs) available were enrolled into the study between December 2015 and May 2016. All patients underwent ECG and echocardiography, and were taken blood and urine samples. Patients were divided into two groups according to presence of fQRS (group 1) or absence of fQRS (group 2). Both groups had similar baseline characteristics. MAU and glycosylated hemoglobin (HbA1c) levels and left ventricular end-diastolic diameter (LVEDd) were increased in patients with a fQRS in the ECG (p=0.002, p=0.02, and p=0.007, respectively). Univariate and multivariate logistic regression analysis showed MAU and an increased LVEDd to be independent risk factors for the presence of a fQRS in the ECG of T2DM patients. In this study, a fQRS was associated to MAU. In T2DM, MAU may be related to subclinical diastolic and systolic dysfunction. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  13. Fragmented QRS may predict new onset atrial fibrillation in patients with ST-segment elevation myocardial infarction.

    PubMed

    Yesin, Mahmut; Kalçık, Macit; Çağdaş, Metin; Karabağ, Yavuz; Rencüzoğulları, İbrahim; Gürsoy, Mustafa Ozan; Efe, Süleyman Çağan; Karakoyun, Süleyman

    Fragmented QRS (fQRS) has been shown to be a marker of local myocardial conduction abnormalities, cardiac fibrosis in previous studies. It was also reported to be a predictor of sudden cardiac death and increased morbidity and mortality in selected populations. However, there is no study investigating the role of fQRS in the development of atrial fibrillation in patients with ST segment elevation myocardial infarction (STEMI). In this study we aimed to investigate the relationship between the presence of fQRS after primary percutaneous coronary intervention (pPCI) and in-hospital development of new-onset atrial fibrilation (AF) in patients with STEMI. This study enrolled 171 patients undergoing pPCI for STEMI. Among these patients 24 patients developed AF and the remaining 147 patients were designated as the controls. All clinical, demographical and laboratory parameters were entered into a dataset and compared between AF group and the controls. The presence of fQRS was higher in the AF group than in the controls (P=0.001). Diabetes mellitus and fQRS was significantly more common in the AF group (P=0.003 and P=0.001 respectively) Logistic regression analysis demonstrated that the presence of fQRS was the independent determinant of AF (OR: 3.243, 95% CI 1.016-10.251, P=0.042). Increased atrial fibrillation was observed more frequently in STEMI patients with fQRS than in patients without fQRS. fQRS is an important determinant of AF in STEMI after pPCI. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Aiding the Detection of QRS Complex in ECG Signals by Detecting S Peaks Independently.

    PubMed

    Sabherwal, Pooja; Singh, Latika; Agrawal, Monika

    2018-03-30

    In this paper, a novel algorithm for the accurate detection of QRS complex by combining the independent detection of R and S peaks, using fusion algorithm is proposed. R peak detection has been extensively studied and is being used to detect the QRS complex. Whereas, S peaks, which is also part of QRS complex can be independently detected to aid the detection of QRS complex. In this paper, we suggest a method to first estimate S peak from raw ECG signal and then use them to aid the detection of QRS complex. The amplitude of S peak in ECG signal is relatively weak than corresponding R peak, which is traditionally used for the detection of QRS complex, therefore, an appropriate digital filter is designed to enhance the S peaks. These enhanced S peaks are then detected by adaptive thresholding. The algorithm is validated on all the signals of MIT-BIH arrhythmia database and noise stress database taken from physionet.org. The algorithm performs reasonably well even for the signals highly corrupted by noise. The algorithm performance is confirmed by sensitivity and positive predictivity of 99.99% and the detection accuracy of 99.98% for QRS complex detection. The number of false positives and false negatives resulted while analysis has been drastically reduced to 80 and 42 against the 98 and 84 the best results reported so far.

  15. Delaware Stars for Early Success. QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Delaware's Stars for Early Success prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators…

  16. Vermont STep Ahead Recognition System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Vermont's STep Ahead Recognition System (STARS) prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for All Child Care Programs;…

  17. Kentucky STARS for KIDS NOW: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Kentucky's STARS for KIDS NOW prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  18. New Hampshire Quality Rating System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of New Hampshire's Quality Rating System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4)…

  19. 2D.03: IMPROVING DIAGNOSTIC STRATEGY IN PATIENTS WITH LONG-STANDING HYPERTENSION, CHEST PAIN AND NORMAL RESTING ECG: VALUE OF THE EXERCISE HIGH-FREQUENCY QRS VERSUS ST-SEGMENT ANALYSIS.

    PubMed

    Conti, A; Bianchi, S; Grifoni, C; Trausi, F; Angeli, E; Paolini, D; Catarzi, S; Perrotta, M E; Covelli, A; Renzi, N; Bertolini, P; Mazzucchelli, M

    2015-06-01

    The novel exercise computer-assisted high-frequency QRS-analysis (ex-HF/QRS) has demonstrated improved sensitivity and specificity over the conventional exercise-ST/ECG-segment-analysis (ex-ST/ECG) in the detection of myocardial ischemia. The aim of the present study was to test the implementation in diagnostic value of the ex-HF/QRS in patient with hypertension and chest pain (CP) versus the conventional ex-ST/ECG anlysis alone. Patients with long-standing hypertension, CP, normal ECG, troponin and echocardiography were enrolled. All patients underwent the ex-ST/ECG and ex-HF/QRS. A decrease >/=50% of the signal of ex-HF/QRS intensity recorded in two contiguous leads, at least, was considered as index of ischaemia, as ST-segment depression >/=2 mm or >/=1 mm and CP on ex-ST/ECG. Exclusion criteria were QRS duration >/=120 msec and inability to exercise. The end-point was the composite of coronary stenosis >50% or acute coronary syndrome, revascularization, cardiovascular death at 3-month follow-up. Six-hundred thirty-one patients were enrolled (age 61+/-15 y). The percentage of age-adjusted maximal predicted heart rate was 88+/-10 beat-per-minute and the maximal systolic blood pressure was 169+/-22 mmHg. Twenty-seven patients achieved the end-point. On multivariate analysis, both the ex-ST/ECG and ex-HF/QRS were predictors of the end-point. The ex-HF/QRS showed higher sensitivity (88% vs 50%; p = 0.003), lower specificity (77% vs 97%; p = 0.245) and comparable negative predictive value (99% vs 99%; p = NS) when compared to ex-ST/ECG. Receiver operator characteristics (ROC) analysis showed the incremental diagnostic value of the ex-HF/QRS (area: 0.64, 95% Confidence Intervals, CI 0.51-0.77) over conventional ex-ST/ECG (0.60, CI 0.52-0.66) and Chest Pain Score (0.53, CI 0.48-0.59); p = NS on pairwise C-statistic. In patients with long-standing hypertension and CP submitted to risk stratification with exercise tolerance test, the novel ex-HF/QRS

  20. Prolonged QRS duration on surface electrocardiogram is associated with left ventricular restrictive filling pattern.

    PubMed

    Erdoğan, Turan; Durakoğlugil, Murtaza Emre; Çiçek, Yüksel; Çetin, Mustafa; Duman, Hakan; Şatiroğlu, Ömer; Çelik, Şükrü

    2017-03-01

    Prolonged QRS duration is associated with decreased left ventricular (LV) systolic function. However, the relation between LV restrictive filling pattern (RFP) and QRS duration has not been investigated yet. The purpose of our study was to assess this relationship. We analyzed standard 12-lead surface electrocardiogram (ECG) of 155 consecutive patients. Mitral inflow and septal tissue velocities were obtained using the apical 4-chamber view with pulsed Doppler echocardiography. Patients were divided into 2 groups according to measured deceleration time (DT): restrictive (with DT ≤130 ms) or non-restrictive (with DT >130 ms). QRS duration was significantly longer in the restrictive group than in the non-restrictive group (0.101 vs. 0.090 s, p  < 0.0001). QRS duration of >0.10 s was highly specific (82.6%), but modestly sensitive (64.7%), for the prediction of LV RFP. Multivariate analyses demonstrated that E/A ratio, peak E, peak A, septal e', and a' velocities were significantly associated with RFP. Prolonged QRS duration (>0.10 s) obtained from a standard resting 12-lead ECG is associated with LV RFP. However, the relationship of QRS duration with RFP was not independent of echocardiographic parameters.

  1. Ohio Step Up to Quality: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Ohio's Step Up to Quality prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  2. Electrical remodeling reflected by QRS and T vector changes following cardiac resynchronization therapy is related to survival in heart failure patients with left bundle branch block.

    PubMed

    Floré, V; Bartunek, J; Goethals, M; Verstreken, S; Timmermans, W; De Pauw, F; Van Bockstal, K; Vanderheyden, M

    2015-01-01

    We investigated changes in electrocardiographic spatial QRS and T vectors as markers of electrical remodeling before and after cardiac resynchronization therapy (CRT) and their association with altered outcome. In 41 patients with LBBB, ECGpost was recorded during intrinsic rhythm after interrupting CRT pacing and compared to the pre-implant ECGpre and the ECG during CRT (ECGCRT). Mean spatial angles between QRS and T vectors were determined with the Kors matrix conversion. Left ventricular ejection fraction (LVEF) was determined with nuclear isotope ventriculography before CRT implantation (LVEFpre) and at inclusion (LVEFpost). Following CRT, LVEF improved significantly from 26 ± 10 to 36 ± 14% (p=0.01). Duration of QRSpre (168 ± 15 ms) was not different from QRSpost (166 ± 15 ms). A smaller angle between QRSCRT and Tpost was related to a greater angle between Tpre and Tpost (Pearson's R -0.61 - p<0.001). During follow-up (30 ± 2 months) 9 patients (22%) died. Univariate Cox regression revealed higher mortality in the patients with lower LVEFpost (HR 1.10, p=0.01), a larger angle QRSCRTTpost (HR 1.03, p=0.03), a smaller angle QRSpreQRSpost (HR 0.97, p=0.03) and smaller angle TpreTpost (HR 0.95, p<0.01). After adjusting for LVEFpost, only smaller angle TpreTpost was associated with mortality (HR 0.96, p=0.03). Electrical remodeling can be quantified by measuring the angles between spatial QRS and T vectors before, during and after CRT. In absence of QRS duration changes, more extensive electrical remodeling is associated with a significantly better survival. QRS and T vector changes deserve further investigation to better understand the individual response to CRT. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Mechanical Dyssynchrony Precedes QRS Widening in ATP‐Sensitive K+ Channel–Deficient Dilated Cardiomyopathy

    PubMed Central

    Yamada, Satsuki; Arrell, D. Kent; Kane, Garvan C.; Nelson, Timothy J.; Perez‐Terzic, Carmen M.; Behfar, Atta; Purushothaman, Saranya; Prinzen, Frits W.; Auricchio, Angelo; Terzic, Andre

    2013-01-01

    Background Contractile discordance exacerbates cardiac dysfunction, aggravating heart failure outcome. Dissecting the genesis of mechanical dyssynchrony would enable an early diagnosis before advanced disease. Methods and Results High‐resolution speckle‐tracking echocardiography was applied in a knockout murine surrogate of adult‐onset human cardiomyopathy caused by mutations in cardioprotective ATP‐sensitive K+ (KATP) channels. Preceding the established criteria of cardiac dyssynchrony, multiparametric speckle‐based strain resolved nascent erosion of dysfunctional regions within cardiomyopathic ventricles of the KATP channel–null mutant exposed to hemodynamic stress. Not observed in wild‐type counterparts, intraventricular disparity in wall motion, validated by the degree, direction, and delay of myocardial speckle patterns, unmasked the disease substrate from asymptomatic to overt heart failure. Mechanical dyssynchrony preceded widening of the QRS complex and exercise intolerance and progressed into global myocardial discoordination and decompensated cardiac pump function, precipitating a low output syndrome. Conclusions The present study, with the use of high‐resolution imaging, prospectively resolved the origin and extent of intraventricular motion disparity in a KATP channel–knockout model of dilated cardiomyopathy. Mechanical dyssynchrony established as an early marker of cardiomyopathic disease offers novel insight into the pathodynamics of dyssynchronous heart failure. PMID:24308936

  4. Prolonged QRS duration on surface electrocardiogram is associated with left ventricular restrictive filling pattern

    PubMed Central

    Erdoğan, Turan; Durakoğlugil, Murtaza Emre; Çiçek, Yüksel; Çetin, Mustafa; Duman, Hakan; Şatiroğlu, Ömer; Çelik, Şükrü

    2017-01-01

    Background Prolonged QRS duration is associated with decreased left ventricular (LV) systolic function. However, the relation between LV restrictive filling pattern (RFP) and QRS duration has not been investigated yet. The purpose of our study was to assess this relationship. Methods We analyzed standard 12-lead surface electrocardiogram (ECG) of 155 consecutive patients. Mitral inflow and septal tissue velocities were obtained using the apical 4-chamber view with pulsed Doppler echocardiography. Patients were divided into 2 groups according to measured deceleration time (DT): restrictive (with DT ≤130 ms) or non-restrictive (with DT >130 ms). Results QRS duration was significantly longer in the restrictive group than in the non-restrictive group (0.101 vs. 0.090 s, p < 0.0001). QRS duration of >0.10 s was highly specific (82.6%), but modestly sensitive (64.7%), for the prediction of LV RFP. Multivariate analyses demonstrated that E/A ratio, peak E, peak A, septal e’, and a’ velocities were significantly associated with RFP. Conclusions Prolonged QRS duration (>0.10 s) obtained from a standard resting 12-lead ECG is associated with LV RFP. However, the relationship of QRS duration with RFP was not independent of echocardiographic parameters. PMID:28932490

  5. Tennessee Star-Quality Child Care Program: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Tennessee's Star-Quality Child Care Program prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4)…

  6. North Carolina Star Rated License System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of North Carolina's Star Rated License System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4)…

  7. Oregon Child Care Quality Indicators Program: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Oregon's Child Care Quality Indicators Program prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4)…

  8. Rapid recovery from congestive heart failure following successful radiofrequency catheter ablation in a patient with late onset of Wolff-Parkinson-White syndrome.

    PubMed

    Yodogawa, Kenji; Ono, Norihiko; Seino, Yoshihiko

    2012-01-01

    A 56-year-old man was admitted because of palpitations and dyspnea. A 12-lead electrocardiogram showed irregular wide QRS complex tachycardia with a slur at the initial portion of the QRS complex. He had preexisting long-standing persistent atrial fibrillation, but early excitation syndrome had never been noted. Chest X-ray showed heart enlargement and pulmonary congestion. He was diagnosed with late onset of Wolff-Parkinson-White syndrome, and congestive heart failure was probably caused by rapid ventricular response of atrial fibrillation through the accessory pathway. Emergency catheter ablation for the accessory pathway was undertaken, and heart failure was dramatically improved.

  9. Real-time, high frequency QRS electrocardiograph

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T. (Inventor); DePalma, Jude L. (Inventor); Moradi, Saeed (Inventor)

    2006-01-01

    Real time cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed in real time in a useful form on a computer screen or monitor. The monitor displays the high frequency data from the QRS complex in units of microvolts, juxtaposed with a display of conventional ECG data in units of millivolts or microvolts. The high frequency data are analyzed for their root mean square (RMS) voltage values and the discrete RMS values and related parameters are displayed in real time. The high frequency data from the QRS complex are analyzed with imbedded algorithms to determine the presence or absence of reduced amplitude zones, referred to herein as RAZs. RAZs are displayed as go, no-go signals on the computer monitor. The RMS and related values of the high frequency components are displayed as time varying signals, and the presence or absence of RAZs may be similarly displayed over time.

  10. The roles of the Q (q) wave in lead I and QRS frontal axis for diagnosing loss of left ventricular capture during cardiac resynchronization therapy.

    PubMed

    Cao, Yuan-Yuan; Su, Yan-Gang; Bai, Jin; Wang, Wei; Wang, Jing-Feng; Qin, Sheng-Mei; Ge, Jun-Bo

    2015-01-01

    Loss of left ventricular (LV) capture may lead to deterioration of heart failure in patients with cardiac resynchronization therapy (CRT). Recognition of loss of LV capture in time is important in clinical practice. A total of 422 electrocardiograms were acquired and analyzed from 53 CRT patients at 8 different pacing settings (LV only, right ventricle [RV] only, biventricular [BV] pacing with LV preactivation of 60, 40, 20, and 0 milliseconds and RV preactivation of 20 and 40 milliseconds). A modified Ammann algorithm by adding a third step-presence of Q (q, or QS) wave-to the original 2-step Ammann algorithm and a QRS axis shift method were devised to identify the loss of LV capture. The accuracy of modified Ammann algorithm was significantly higher than that of Ammann algorithm (78.9% vs. 69.1%, P < 0.001). The accuracy of the axis shift method was 66.4%, which was significantly lower than the modified Ammann algorithm (P < 0.001) and similar to the original one (P = 0.412). However, in the ECGs with QRS axis shift, 96.8% were correctly classified. LV preactivation or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall could elevate the accuracies of the modified Ammann algorithm and the QRS axis shift method. The accuracy of the modified Ammann algorithm is greatly improved. The QRS axis shift method can help diagnose LV capture. The LV preactivation, or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall can increase the diagnostic power of the modified Ammann algorithm and QRS axis shift method. © 2014 Wiley Periodicals, Inc.

  11. Identification of QRS complex in non-stationary electrocardiogram of sick infants.

    PubMed

    Kota, S; Swisher, C B; Al-Shargabi, T; Andescavage, N; du Plessis, A; Govindan, R B

    2017-08-01

    Due to the high-frequency of routine interventions in an intensive care setting, electrocardiogram (ECG) recordings from sick infants are highly non-stationary, with recurrent changes in the baseline, alterations in the morphology of the waveform, and attenuations of the signal strength. Current methods lack reliability in identifying QRS complexes (a marker of individual cardiac cycles) in the non-stationary ECG. In the current study we address this problem by proposing a novel approach to QRS complex identification. Our approach employs lowpass filtering, half-wave rectification, and the use of instantaneous Hilbert phase to identify QRS complexes in the ECG. We demonstrate the application of this method using ECG recordings from eight preterm infants undergoing intensive care, as well as from 18 normal adult volunteers available via a public database. We compared our approach to the commonly used approaches including Pan and Tompkins (PT), gqrs, wavedet, and wqrs for identifying QRS complexes and then compared each with manually identified QRS complexes. For preterm infants, a comparison between the QRS complexes identified by our approach and those identified through manual annotations yielded sensitivity and positive predictive values of 99% and 99.91%, respectively. The comparison metrics for each method are as follows: PT (sensitivity: 84.49%, positive predictive value: 99.88%), gqrs (85.25%, 99.49%), wavedet (95.24%, 99.86%), and wqrs (96.99%, 96.55%). Thus, the sensitivity values of the four methods previously described, are lower than the sensitivity of the method we propose; however, the positive predictive values of these other approaches is comparable to those of our method, with the exception of the wqrs approach, which yielded a slightly lower value. For adult ECG, our approach yielded a sensitivity of 99.78%, whereas PT yielded 99.79%. The positive predictive value was 99.42% for both our approach as well as for PT. We propose a novel method for

  12. QRS analysis using wavelet transformation for the prediction of response to cardiac resynchronization therapy: a prospective pilot study.

    PubMed

    Vassilikos, Vassilios P; Mantziari, Lilian; Dakos, Georgios; Kamperidis, Vasileios; Chouvarda, Ioanna; Chatzizisis, Yiannis S; Kalpidis, Panagiotis; Theofilogiannakos, Efstratios; Paraskevaidis, Stelios; Karvounis, Haralambos; Mochlas, Sotirios; Maglaveras, Nikolaos; Styliadis, Ioannis H

    2014-01-01

    Wider QRS and left bundle branch block morphology are related to response to cardiac resynchronization therapy (CRT). A novel time-frequency analysis of the QRS complex may provide additional information in predicting response to CRT. Signal-averaged electrocardiograms were prospectively recorded, before CRT, in orthogonal leads and QRS decomposition in three frequency bands was performed using the Morlet wavelet transformation. Thirty eight patients (age 65±10years, 31 males) were studied. CRT responders (n=28) had wider baseline QRS compared to non-responders and lower QRS energies in all frequency bands. The combination of QRS duration and mean energy in the high frequency band had the best predicting ability (AUC 0.833, 95%CI 0.705-0.962, p=0.002) followed by the maximum energy in the high frequency band (AUC 0.811, 95%CI 0.663-0.960, p=0.004). Wavelet transformation of the QRS complex is useful in predicting response to CRT. © 2013.

  13. Iowa Child Care Quality Rating System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Iowa's Child Care Quality Rating System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile is divided into the following categories: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family Child Care Programs;…

  14. The value of electrocardiography for differential diagnosis in wide QRS complex tachycardia.

    PubMed

    Sousa, Pedro A; Pereira, Salomé; Candeias, Rui; de Jesus, Ilídio

    2014-03-01

    Correct diagnosis in wide QRS complex tachycardia remains a challenge. Differential diagnosis between ventricular and supraventricular tachycardia has important therapeutic and prognostic implications, and although data from clinical history and physical examination may suggest a particular origin, it is the 12-lead surface electrocardiogram that usually enables this differentiation. Since 1978, various electrocardiographic criteria have been proposed for the differential diagnosis of wide complex tachycardias, particularly the presence of atrioventricular dissociation, and the axis, duration and morphology of QRS complexes. Despite the wide variety of criteria, diagnosis is still often difficult, and errors can have serious consequences. To reduce such errors, several differential diagnosis algorithms have been proposed since 1991. However, in a small percentage of wide QRS tachycardias the diagnosis remains uncertain and in these the wisest decision is to treat them as ventricular tachycardias. The authors' objective was to review the main electrocardiographic criteria and differential diagnosis algorithms of wide QRS tachycardia. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  15. Louisiana Quality Start Child Care Rating System: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Louisiana's Quality Start Child Care Rating System prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs;…

  16. Los Angeles County Steps to Excellence Project: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Los Angeles County's Steps to Excellence Project prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs;…

  17. Perspectives of human verification via binary QRS template matching of single-lead and 12-lead electrocardiogram.

    PubMed

    Krasteva, Vessela; Jekova, Irena; Schmid, Ramun

    2018-01-01

    This study aims to validate the 12-lead electrocardiogram (ECG) as a biometric modality based on two straightforward binary QRS template matching characteristics. Different perspectives of the human verification problem are considered, regarding the optimal lead selection and stability over sample size, gender, age, heart rate (HR). A clinical 12-lead resting ECG database, including a population of 460 subjects with two-session recordings (>1 year apart) is used. Cost-effective strategies for extraction of personalized QRS patterns (100ms) and binary template matching estimate similarity in the time scale (matching time) and dissimilarity in the amplitude scale (mismatch area). The two-class person verification task, taking the decision to validate or to reject the subject identity is managed by linear discriminant analysis (LDA). Non-redundant LDA models for different lead configurations (I,II,III,aVF,aVL,aVF,V1-V6) are trained on the first half of 230 subjects by stepwise feature selection until maximization of the area under the receiver operating characteristic curve (ROC AUC). The operating point on the training ROC at equal error rate (EER) is tested on the independent dataset (second half of 230 subjects) to report unbiased validation of test-ROC AUC and true verification rate (TVR = 100-EER). The test results are further evaluated in groups by sample size, gender, age, HR. The optimal QRS pattern projection for single-lead ECG biometric modality is found in the frontal plane sector (60°-0°) with best (Test-AUC/TVR) for lead II (0.941/86.8%) and slight accuracy drop for -aVR (-0.017/-1.4%), I (-0.01/-1.5%). Chest ECG leads have degrading accuracy from V1 (0.885/80.6%) to V6 (0.799/71.8%). The multi-lead ECG improves verification: 6-chest (0.97/90.9%), 6-limb (0.986/94.3%), 12-leads (0.995/97.5%). The QRS pattern matching model shows stable performance for verification of 10 to 230 individuals; insignificant degradation of TVR in women by (1.2-3.6%), adults

  18. Association of QRS duration and survival in dogs with dilated cardiomyopathy: a retrospective study of 266 clinical cases.

    PubMed

    Pedro, Brigite M; Alves, Joana V; Cripps, Peter J; Stafford Johnson, Mike J; Martin, Mike W S

    2011-12-01

    The purpose of this study was to investigate the prognostic value of QRS duration in dogs with dilated cardiomyopathy (DCM) by studying its relationship with survival time. The medical records of dogs diagnosed with DCM were retrospectively searched for good quality ECG tracings. The QRS duration was measured from the ECG tracing and two different models were used: binary variable (dogs were divided into 2 groups based on a QRS duration of <60 ms or ≥60 ms) and continuous variable. The survival times were analysed by the Kaplan-Meier method and Cox's proportional hazard model. 266 dogs met the inclusion and exclusion criteria. A QRS duration ≥60 ms was associated with a reduced survival time compared to those with a QRS duration <60 ms (Hazard Ratio of 1.34, 95% CI 1.05-1.71, P = 0.02). When considered as a continuous variable the Hazard Ratio was 1.015 for each increase in QRS duration of 1 ms (95% CI 1.006-1.024, p = 0.001).Dogs with a QRS duration < 60 ms had a median survival time (IQ range) of 25 weeks (97-65) and dogs with a QRS duration ≥60 ms had a median survival time (IQ range) of 13 weeks (3-34). The measurement of QRS duration is relatively simple to perform from a surface ECG recording. A duration ≥60 ms is associated with shorter survival times in dogs with DCM, which may provide practitioners with additional prognostic information. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Response of the ECG to short-term diuresis in patients with heart failure.

    PubMed

    Madias, John E; Song, Jessica; White, C Michael; Kalus, James S; Kluger, Jeffrey

    2005-07-01

    Increase in the amplitude of electrocardiogram (ECG) QRS complexes has been observed in patients treated for heart failure (HF), but the underlying mechanism has not been delineated. Also, correlation of augmentation of the QRS potentials with loss of weight has been noted in patients recovering from anasarca of varying etiology, or after hemodialysis. We assessed the effect of diuresis-based fluid loss in patients treated for HF on the amplitude of ECG QRS complexes. This is a cohort study based on ECG and other data from a previously published investigation of patients with HF conducted at a university affiliated hospital, which used new measurements and analysis, performed by a totally blinded investigator based at another institution. Twenty-one patients (10 men) aged 70.5+/-12.7 years, 13 with ischemic, and 8 with nonischemic cardiomyopathy, were admitted to the hospital for management of exacerbated HF and were observed for 48 hours. The patients received diuresis, and had routine laboratory testing, documentation of the net fluid lost, and recording of ECGs prior to the initiation of therapy and at 24 and 48 hours. Percent change (%Delta) over the course of observation in the sums of the amplitude of QRS complexes from 12 leads (SigmaQRS12), 6-limb leads (SigmaQRS6), and leads 1+2 (SigmaQRS2) in mm of standard ECGs were correlated with net fluid loss corrected for admission weight in mL/kg. Fluid loss amounted to 3204.9+/-1399.5 mL in the course of 40+/-23 hours of diuresis. SigmaQRS12 was 160.9+/-42.3 mm before and 170.0+/-50.7 mm after diuresis (P=0. 024). Percent change in SigmaQRS12, SigmaQRS6, and SigmaQRS2 correlated well with the net fluid loss (r=-0.70, -0.82, -0.61, and P=0.002, 0.0005, 0.001) correspondingly. Changes in sums of the amplitude of QRS complexes of the standard ECG correlates well with net fluid loss in response to short-term diuresis in patients with HF. Change in the SigmaQRS12, SigmaQRS6, and SigmaQRS2 from ECGs before and after

  20. QRS slopes for assessment of myocardial damage in chronic chagasic patients

    NASA Astrophysics Data System (ADS)

    Pueyo, E.; Laciar, E.; Anzuola, E.; Laguna, P.; Jané, R.

    2007-11-01

    In this study the slopes of the QRS complex are evaluated for determination of the degree of myocardial damage in chronic chagasic patients. Previous studies have demonstrated the ability of the slope indices to reflect alterations in the conduction velocity of the cardiac impulse. Results obtained in the present study show that chronic chagasic patients have significantly flatter QRS slopes as compared to healthy subjects. Not only that but the extent of slope lessening turns out to be proportional to the degree of myocardial damage caused by the disease. Additionally, when incorporating the slope indices into a classification analysis together with other indices indicative of the presence of ventricular late potentials obtained from high resolution electrocardiography, results show that the percentages of correct classification increase up to 62.5%, which means eight points above the percentages obtained prior to incorporation of the slope indices. It can be concluded that QRS slopes have great potential for assessing the degree of severity associated with Chagas' disease.

  1. New Mexico Look for the STARS--AIM HIGH: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of New Mexico's Look for the STARS--AIM HIGH prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4)…

  2. Intramyocardial arterial narrowing in dogs with subaortic stenosis.

    PubMed

    Falk, T; Jönsson, L; Pedersen, H D

    2004-09-01

    Earlier studies have described intramyocardial arterial narrowing based on hyperplasia and hypertrophy of the vessel wall in dogs with subaortic stenosis (SAS). In theory, such changes might increase the risk of sudden death, as they seem to do in heart disease in other species. This retrospective pathological study describes and quantifies intramyocardial arterial narrowing in 44 dogs with naturally occurring SAS and in eight control dogs. The majority of the dogs with SAS died suddenly (n=27); nine had died or been euthanased with signs of heart failure and eight were euthanased without clinical signs. Dogs with SAS had significantly narrower intramyocardial arteries (P<0.001) and more myocardial fibrosis (P<0.001) than control dogs. Male dogs and those with more severe hypertrophy had more vessel narrowing (P=0.02 and P=0.02, respectively), whereas dogs with dilated hearts had slightly less pronounced arterial thickening (P=0.01). Arterial narrowing was not related to age, but fibrosis increased with age (P=0.047). Dogs that died suddenly did not have a greater number of arterial changes than other dogs with SAS. This study suggests that most dogs with SAS have intramyocardial arterial narrowing and that the risk of dying suddenly is not significantly related to the overall degree of vessel obliteration.

  3. Analysis of the QRS complex for apnea-bradycardia characterization in preterm infants

    PubMed Central

    Altuve, Miguel; Carrault, Guy; Cruz, Julio; Beuchée, Alain; Pladys, Patrick; Hernandez, Alfredo I.

    2009-01-01

    This work presents an analysis of the information content of new features derived from the electrocardiogram (ECG) for the characterization of apnea-bradycardia events in preterm infants. Automatic beat detection and segmentation methods have been adapted to the ECG signals from preterm infants, through the application of two evolutionary algorithms. ECG data acquired from 32 preterm infants with persistent apnea-bradycardia have been used for quantitative evaluation. The adaptation procedure led to an improved sensitivity and positive predictive value, and a reduced jitter for the detection of the R-wave, QRS onset, QRS offset, and iso-electric level. Additionally, time series representing the RR interval, R-wave amplitude and QRS duration, were automatically extracted for periods at rest, before, during and after apnea-bradycardia episodes. Significant variations (p<0.05) were observed for all time-series when comparing the difference between values at rest versus values just before the bradycardia event, with the difference between values at rest versus values during the bradycardia event. These results reveal changes in the R-wave amplitude and QRS duration, appearing at the onset and termination of apnea-bradycardia episodes, which could be potentially useful for the early detection and characterization of these episodes. PMID:19963984

  4. An individual patient meta-analysis of five randomized trials assessing the effects of cardiac resynchronization therapy on morbidity and mortality in patients with symptomatic heart failure.

    PubMed

    Cleland, John G; Abraham, William T; Linde, Cecilia; Gold, Michael R; Young, James B; Claude Daubert, J; Sherfesee, Lou; Wells, George A; Tang, Anthony S L

    2013-12-01

    Cardiac resynchronization therapy (CRT) with or without a defibrillator reduces morbidity and mortality in selected patients with heart failure (HF) but response can be variable. We sought to identify pre-implantation variables that predict the response to CRT in a meta-analysis using individual patient-data. An individual patient meta-analysis of five randomized trials, funded by Medtronic, comparing CRT either with no active device or with a defibrillator was conducted, including the following baseline variables: age, sex, New York Heart Association class, aetiology, QRS morphology, QRS duration, left ventricular ejection fraction (LVEF), and systolic blood pressure. Outcomes were all-cause mortality and first hospitalization for HF or death. Of 3782 patients in sinus rhythm, median (inter-quartile range) age was 66 (58-73) years, QRS duration was 160 (146-176) ms, LVEF was 24 (20-28)%, and 78% had left bundle branch block. A multivariable model suggested that only QRS duration predicted the magnitude of the effect of CRT on outcomes. Further analysis produced estimated hazard ratios for the effect of CRT on all-cause mortality and on the composite of first hospitalization for HF or death that suggested increasing benefit with increasing QRS duration, the 95% confidence bounds excluding 1.0 at ∼140 ms for each endpoint, suggesting a high probability of substantial benefit from CRT when QRS duration exceeds this value. QRS duration is a powerful predictor of the effects of CRT on morbidity and mortality in patients with symptomatic HF and left ventricular systolic dysfunction who are in sinus rhythm. QRS morphology did not provide additional information about clinical response. NCT00170300, NCT00271154, NCT00251251.

  5. The T/QRS ratio values in pregnancies complicated by threatened preterm labour treated with intravenous infusions of fenoterol.

    PubMed

    Fuchs, Tomasz; Pomorski, Michał; Grobelak, Krzysztof; Zimmer, Mariusz

    2015-07-01

    To evaluate values of foetal T/QRS ratios in pregnancies complicated by threatened preterm labour treated with intravenous infusions of fenoterol using non-invasive methods with transabdominal electrodes. The study group consisted of 451 Caucasian women (63 preterm pregnancies and 327 healthy controls) whose pregnancies ranged from 28 to 37 gestational weeks. Foetal electrocardiograms were recorded and T/QRS ratios were calculated by KOMPOREL software (ITAM, Zabrze, Poland). The first recording was performed 30 min after the start of fenoterol infusion and the second 2 days after finishing tocolysis. T/QRS ratio variables were calculated. One-way analysis of variance was carried out. Significantly higher mean values of the T/QRS ratio were observed in pregnancies during tocolytic treatment in comparison to controls and pregnancies after tocolysis (P=0.0158 and P=0.0071, respectively). The T/QRS ratio values fall again shortly after finishing intravenous tocolysis. The T/QRS ratio is one of the methods used for non-invasive foetal distress assessment that can be used in antepartum foetal monitoring in complicated pregnancies. Raised values of the T/QRS ratio in the foetus during tocolysis with fenoterol and next its fall to values observed in physiological pregnancies may indicate transient worsening of fetal well-being, however, additional research is required.

  6. Comparison between fragmented QRS and Q waves in myocardial scar detection using myocardial perfusion single photon emission computed tomography.

    PubMed

    Dabbagh Kakhki, Vahid Reza; Ayati, Narjess; Zakavi, Seyed Rasoul; Sadeghi, Ramin; Tayyebi, Mohammad; Shariati, Farzaneh

    2015-01-01

    Accurate diagnosis of myocardial infarction (MI) is of paramount importance in patient management, which necessitates the development of efficient and accurate diagnostic methods. Q wave is not present in all patients with MI, and its prevalence is declining. Recently, fragmented QRS (fQRS) complex has been introduced as a marker of prior MI. To investigate diagnostic value of fQRS compared to Q wave. We included 500 consecutive patients with known or suspected coronary artery disease who underwent two days of gated myocardial perfusion imaging using dipyridamole pharmacologic stress. Electrocardiogram (ECG) was evaluated to detect fQRS as well as Q-wave. Finally, subjects were compared in terms of ventricular perfusion and function indices. A total of 207 men and 269 women with mean age of 57.06 ± 12 years were studied. ECG analysis showed that 14.3% of the patients had both fQRS and Q waves, 30.7% had fQRS, and 3.8% had Q waves. Fixed myocardial perfusion defect was noted in 22.3% of patients according to MPIs. Sensitivity, specificity, and positive and negative predictive values for myocardial scar detection were 78%, 65%, 39%, and 91%, respectively, for fQRS and 61%, 94%, 76%, and 89%, respectively, for Q wave. Although fQRS had lower specificity compared to Q wave in the detection of myocardial scar, due to higher sensitivity and negative predictive value can be an invaluable diagnostic index. There is also an incremental value for fQRS in association with Q-wave in myocardial scar assessment.

  7. Echocardiographic evaluation of cardiac dyssynchrony in patients with congestive heart failure.

    PubMed

    Qin, Chuan; Zhang, Li; Zhang, Zi-Ming; Wang, Bin; Ye, Zhou; Wang, Yong; Nanda, Navin C; Xie, Ming-Xing

    2016-06-01

    The present study investigated the application of echocardiography to evaluation of cardiac dyssynchrony in patients with congestive heart failure (CHF). A total of 348 consecutive CHF patients who were admitted for cardiac resynchronization (CRT) and presented with low ejection fraction (EF) and wide QRS duration were enrolled in this study, along with 388 healthy individuals. Dyssynchrony was assessed based on filling time ratio (FT/RR), left ventricular pre-ejection delay (PED), interventricular mechanical delay (IVMD), longitudinal opposing wall delay (LOWD) and radial septal to posterior wall delay (RSPWD). Response to CRT was defined as a ≥15% increase in EF. The results showed that FT/RR was decreased while PED, IVMD, LOWD and RSPWD were increased in the CHF group compared with the control group (P<0.01). In the CHF group, FT/RR was negatively correlated with the QRS duration, LV end-diastolic diameter (LVESd), LV end-diastolic volume (LVEDV) and LV end-systolic volume (LVESV) (P<0.01), but positively with the LVEF (P<0.01). Additionally, PED, IVMD, LOWD and RSPWD were positively correlated with the QRS duration, LVESd, LVEDV and LVESV (P<0.01), but negatively with the LVEF (P<0.01). The CHF group was divided into three subgroups according to the varying degrees of LVEF. FT/RR decreased successively from the LVEF-1 group to the LVEF-2 group to the LVEF-3 group, while the PED, IVMD, LOWD and RSPWD successively increased in the same order (P<0.01). The CHF group was divided into three subgroups according to the varying degrees of QRS duration, and FT/RR decreased successively in a sequence from the QRS-1 group to the QRS-2 group to the QRS-3 group, while the PED, IVMD, LOWD and RSPWD successively increased in the same order (P<0.01). Speckle tracking radial dyssynchrony ≥130 ms was predictive of an EF response in patients in QRS-1 group (78% sensitivity, 83% specificity), those in QRS-2 group (83% sensitivity, 77% specificity) and in QRS-3 group (89

  8. Revisiting QRS detection methodologies for portable, wearable, battery-operated, and wireless ECG systems.

    PubMed

    Elgendi, Mohamed; Eskofier, Björn; Dokos, Socrates; Abbott, Derek

    2014-01-01

    Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices.

  9. Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems

    PubMed Central

    Elgendi, Mohamed; Eskofier, Björn; Dokos, Socrates; Abbott, Derek

    2014-01-01

    Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices. PMID:24409290

  10. Investigation of mindin levels in hypertensive patients with left ventricular hypertrophy and QRS fragmentation on electrocardiography.

    PubMed

    Doğan, Tolga; Yetim, Mucahit; Çelik, Oğuzhan; Kalçık, Macit; Özcan, Oğuzhan; Doğan, İbrahim; Erenler, Ali Kemal; Bekar, Lütfü; Karavelioğlu, Yusuf

    2017-12-21

    Mindin was associated with diabetic nephropathy, podocyte injury, colitis, allergic asthma, liver ischaemia and reperpusion injury and ischaemic brain injury. On the other hand, it was reported as a protective factor against obesity, cardiac hypertrophy, fibrosis and remodelling. Fragmented QRS complexes (fQRS) are markers of altered ventricular depolarisation owing to a prior myocardial scar and fibrosis. In this study, we aimed to investigate mindin levels in hypertensive patients with left ventricular hypertrophy and fQRS on electrocardiography. This observational case-control study enrolled 70 (36 female) hypertensive patients with fQRS and 38 (23 female) hypertensive control patients. All patients were evaluated by transthoracic echocardiography. Mindin levels were measured by the enzyme-linked immunosorbent assay (ELISA). Clinical, echocardiographic and laboratory data were compared between patient and control groups. There was no significant difference between patient and control groups in terms of clinical, echocardiographic and routine laboratory parameters. The mindin levels were significantly higher in the patient group than controls (11.3 (7.21-19.31) vs 4.15 (2.86-6.34); p < .001). Multiple logistic regression analyses defined increased mindin levels as an independent predictor for the presence of fQRS (Odds ratio: 1.733; p = .034). Mindin levels >6.74 predicted the presence of fQRS with a sensitifity of 84.3% and specificity of 79.9% on receiver operating characteristic (ROC) curve analysis (The area under the curve:0.889; Confidence Interval: 0.827-0.951; p < .001). Mindin expressin is upregulated in hypertensive patients with fQRS complexes. In contrary to previous studies, increased mindin levels may be associated with myocardial fibrosis.

  11. On the normal scalar ECG. A new classification system considering age, sex and heart position.

    PubMed

    Lundh, B

    1984-01-01

    472 randomly selected men and women from the city of Lund were examined for disease in the heart, lungs and for hypertension. 163 men and 194 women who had no symptom or sign of disease were accepted for the further study. The prevalence of various exclusion criterias, such as symptoms and signs of heart disease, lung disease and other diseases which may possibly affect the ECG are reported as well as the distribution of blood pressures in the sample. A computer-averaged standard 12-lead ECG (leads aVL, I, -aVR, II, aVF, III, V1-V6) was recorded. All measurements of ECG-deflections have been made visually using a magnifying glass (6 times). ST-segments were classified according to the Punsar code by independent visual observers as well as by the computer. The mean frontal QRS-axis shifted to the left with advancing age, but the shift was statistically significant only in men. In both men and women there was a leftward shift of the mean frontal QRS-axis with increased weight, increased chest circumference and increased obesity index. The normal range of axis was found to be 0 degrees to 90 degrees in men and +15 degrees to 90 degrees in women. The problems concerning the definition of the electrical heart position is discussed. The concept of a Q-axis is introduced as an alternative way to indicate electrical heart position. There is a statistical significant relationship between the Q-axis and the QRS-axis in the frontal plane, although this relationship is not always apparent in the individual ECG. The presence or absence of a Q-wave in an individual lead was used to denote a lead as being a left ventricular lead or not. Using the Q-wave as a marker of heart position in the individual lead is more practical than to use the QRS-axis or the transitional zone. Duration and amplitude of the Q-wave have been measured. The upper limit of normal duration exceeded 0.03 s in leads aVL and aVF in men but not in women. The R-wave amplitudes proved to vary with age and heart

  12. QRS detection based ECG quality assessment.

    PubMed

    Hayn, Dieter; Jammerbund, Bernhard; Schreier, Günter

    2012-09-01

    Although immediate feedback concerning ECG signal quality during recording is useful, up to now not much literature describing quality measures is available. We have implemented and evaluated four ECG quality measures. Empty lead criterion (A), spike detection criterion (B) and lead crossing point criterion (C) were calculated from basic signal properties. Measure D quantified the robustness of QRS detection when applied to the signal. An advanced Matlab-based algorithm combining all four measures and a simplified algorithm for Android platforms, excluding measure D, were developed. Both algorithms were evaluated by taking part in the Computing in Cardiology Challenge 2011. Each measure's accuracy and computing time was evaluated separately. During the challenge, the advanced algorithm correctly classified 93.3% of the ECGs in the training-set and 91.6 % in the test-set. Scores for the simplified algorithm were 0.834 in event 2 and 0.873 in event 3. Computing time for measure D was almost five times higher than for other measures. Required accuracy levels depend on the application and are related to computing time. While our simplified algorithm may be accurate for real-time feedback during ECG self-recordings, QRS detection based measures can further increase the performance if sufficient computing power is available.

  13. When Deriving the Spatial QRS-T Angle from the 12-lead ECG, which Transform is More Frank: Regression or Inverse Dower?

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Cortez, Daniel

    2010-01-01

    Our primary objective was to ascertain which commonly used 12-to-Frank-lead transformation yields spatial QRS-T angle values closest to those obtained from simultaneously collected true Frank-lead recordings. Simultaneous 12-lead and Frank XYZ-lead recordings were analyzed for 100 post-myocardial infarction patients and 50 controls. Relative agreement, with true Frank-lead results, of 12-to-Frank-lead transformed results for the spatial QRS-T angle using Kors regression versus inverse Dower was assessed via ANOVA, Lin s concordance and Bland-Altman plots. Spatial QRS-T angles from the true Frank leads were not significantly different than those derived from the Kors regression-related transformation but were significantly smaller than those derived from the inverse Dower-related transformation (P less than 0.001). Independent of method, spatial mean QRS-T angles were also always significantly larger than spatial maximum (peaks) QRS-T angles. Spatial QRS-T angles are best approximated by regression-related transforms. Spatial mean and spatial peaks QRS-T angles should also not be used interchangeably.

  14. QRS/T-wave and calcium alternans in a type I diabetic mouse model for spontaneous postmyocardial infarction ventricular tachycardia: A mechanism for the antiarrhythmic effect of statins.

    PubMed

    Jin, Hongwei; Welzig, Charles M; Aronovitz, Mark; Noubary, Farzad; Blanton, Robert; Wang, Bo; Rajab, Mohammad; Albano, Alfred; Link, Mark S; Noujaim, Sami F; Park, Ho-Jin; Galper, Jonas B

    2017-09-01

    The incidence of sudden arrhythmic death is markedly increased in diabetics. The purpose of this study was to develop a mouse model for postmyocardial infarction (post-MI) ventricular tachycardia (VT) in the diabetic heart and determine the mechanism of an antiarrhythmic effect of statins. ECG transmitters were implanted in wild-type (WT), placebo, and pravastatin-treated type I diabetic Akita mice. MIs were induced by coronary ligation, and Ca 2+ transients were studied by optical mapping, and Ca 2+ transients and sparks in left ventricular myocytes (VM) by the Ionoptix system and confocal microscopy. Burst pacing of Akita mouse hearts resulted in rate-related QRS/T-wave alternans, which was attenuated in pravastatin-treated mice. Post-MI Akita mice developed QRS/T-wave alternans and VT at 2820 ± 879 beats per mouse, which decreased to 343 ± 115 in pravastatin-treated mice (n = 13, P <.05). Optical mapping demonstrated pacing-induced VT originating in the peri-infarction zone and Ca 2+ alternans, both attenuated in hearts of statin-treated mice. Akita VM displayed Ca 2+ alternans, and triggered activity as well as increased Ca 2+ transient decay time (Tau), Ca 2+ sparks, and cytosolic Ca 2+ and decreased SR Ca 2+ stores all of which were in part reversed in cells from statin treated mice. Homogenates of Akita ventricles demonstrated decreased SERCA2a/PLB ratio and increased ratio of protein phosphatase (PP-1) to the PP-1 inhibitor PPI-1 which were reversed in homogenates of pravastatin-treated Akita mice. Pravastatin decreased the incidence of post-MI VT and Ca 2+ alternans in Akita mouse hearts in part by revering abnormalities of Ca 2+ handling via the PP-1/PPI-1 pathway. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  15. Compendium of Quality Rating Systems and Evaluations: The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Tout, Kathryn; Starr, Rebecca; Soli, Margaret; Moodie, Shannon; Kirby, Gretchen; Boller, Kimberly

    2010-01-01

    Quality Rating Systems (QRS) are currently operating, under development, or being piloted in over 25 states or local areas. As the QRS model becomes integrated into the landscape of child care and education service delivery, policy, and the decisions parents make about child care across the United States, there is an increasing need for…

  16. Case report: an unstable wide QRS complexes tachycardia after ablation of a poster-septal accessory pathway: What is the mechanism?

    PubMed

    Wang, Huan; Che, Xiaoru

    2018-03-01

    Differentiation of wide QRS complex tachycardia required repeated electrophysiological stimuli and mapping. However, instability of tachycardia would increase the difficulty in differential diagnosis. In this paper, we reported a wide QRS tachycardia following ablation of an atrioventricular reentrant tachycardia participated by a poster-septal accessory pathway. Limited differentiation strategy was performed because the wide QRS tachycardia was self-limited and with unstable hemodynamics. We analyzed the mechanism of the wide QRS tachycardia by only 4 beats ventricular overpacing. On the basis of the last ventricular pacing, an atypical atrioventricular nodal reentrant tachycardia was confirmed. After slow-pathway modification, the wide QRS tachycardia was eliminated. It was an atypical atrial-ventricular node reentrant tachycardia with right bundle branch block. Reasonable analysis based on electrophysiological electrophysiologic knowledge was the basis of successful diagnosis and treatment.

  17. The energy-efficient implementation of an adaptive-filtering-based QRS complex detection method for wearable devices

    NASA Astrophysics Data System (ADS)

    Tian, Shudong; Han, Jun; Yang, Jianwei; Zeng, Xiaoyang

    2017-10-01

    Electrocardiogram (ECG) can be used as a valid way for diagnosing heart disease. To fulfill ECG processing in wearable devices by reducing computation complexity and hardware cost, two kinds of adaptive filters are designed to perform QRS complex detection and motion artifacts removal, respectively. The proposed design achieves a sensitivity of 99.49% and a positive predictivity of 99.72%, tested under the MIT-BIH ECG database. The proposed design is synthesized under the SMIC 65-nm CMOS technology and verified by post-synthesis simulation. Experimental results show that the power consumption and area cost of this design are of 160 μW and 1.09 × 10 5 μm2, respectively. Project supported by the National Natural Science Foundation of China (Nos. 61574040, 61234002, 61525401).

  18. District of Columbia Going for the Gold Tiered Rate Reimbursement System. QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of District of Columbia's Going for the Gold Tiered Rate Reimbursement Systemp repared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for…

  19. Left Axis Deviation in Children Without Previously Known Heart Disease.

    PubMed

    Schneider, Andrew E; Cannon, Bryan C; Johnson, Jonathan N; Ackerman, Michael J; Wackel, Philip L

    2018-02-01

    Left axis deviation (LAD) discovered in children via electrocardiogram (ECG) is uncommon but can be associated with heart disease (HD). The optimal diagnostic approach in a seemingly healthy child with LAD is unclear. We sought to better stratify which patients with LAD but without previously known HD may warrant additional workup. A retrospective chart review was performed to identify patients ≥1 to <18 years of age with LAD (QRS frontal plane axis 0 to -90) on an ECG between January 2002 and December 2014. Patients with known HD before their initial ECG were excluded. Overall, 296 patients were identified ( n = 181 [61%] male; mean age: 10.8 ± 4.6 years; mean QRS axis: -24 ± 22°). An echocardiogram was performed in 158 (53%) patients, with 24 (15%) having HD. Compared with those with an echocardiogram but without HD ( n = 134), patients with HD had a more negative mean QRS axis (-42 vs -27°; P = .002) and were more likely to have a QRS axis ≤-42° (58% vs 26%; P = .003), ECG chamber enlargement or hypertrophy (38% vs 5%; P < .0001), and abnormal cardiac physical examination findings (75% vs 8%; P < .0001). LAD discovered in isolation in the asymptomatic pediatric patient may not necessitate further cardiovascular investigation. Clinicians should consider obtaining an echocardiogram in patients with LAD and ECG cardiac chamber enlargement or hypertrophy, a QRS axis ≤-42°, and/or the presence of abnormal cardiac physical examination findings. Copyright © 2018 by the American Academy of Pediatrics.

  20. Data on association between QRS duration on prehospital ECG and mortality in patients with confirmed STEMI.

    PubMed

    Hansen, Rikke; Frydland, Martin; Møller-Helgestad, Ole Kristian; Lindholm, Matias Greve; Jensen, Lisette Okkels; Holmvang, Lene; Ravn, Hanne Berg; Kjærgaard, Jesper; Hassager, Christian; Møller, Jacob Eifer

    2017-12-01

    Data presented in this article relates to the research article entitled " Association between QRS duration on prehospital ECG and mortality in patients with suspected STEMI" (Hansen et al., in press) [1]. Data on the prognostic effect of automatically recoded QRS duration on prehospital ECG and presence of classic left and right bundle branch block in 1777 consecutive patients with confirmed ST segment elevation AMI is presented. Multivariable analysis, suggested that QRS duration >111 ms, left bundle branch block and right bundle branch block were independent predictors of 30 days all-cause mortality. For interpretation and discussion of these data, refer to the research article referenced above.

  1. Linear Phase Sharp Transition BPF to Detect Noninvasive Maternal and Fetal Heart Rate.

    PubMed

    Marchon, Niyan; Naik, Gourish; Pai, K R

    2018-01-01

    Fetal heart rate (FHR) detection can be monitored using either direct fetal scalp electrode recording (invasive) or by indirect noninvasive technique. Weeks before delivery, the invasive method poses a risk factor to the fetus, while the latter provides accurate fetal ECG (FECG) information which can help diagnose fetal's well-being. Our technique employs variable order linear phase sharp transition (LPST) FIR band-pass filter which shows improved stopband attenuation at higher filter orders. The fetal frequency fiduciary edges form the band edges of the filter characterized by varying amounts of overlap of maternal ECG (MECG) spectrum. The one with the minimum maternal spectrum overlap was found to be optimum with no power line interference and maximum fetal heart beats being detected. The improved filtering is reflected in the enhancement of the performance of the fetal QRS detector (FQRS). The improvement has also occurred in fetal heart rate obtained using our algorithm which is in close agreement with the true reference (i.e., invasive fetal scalp ECG). The performance parameters of the FQRS detector such as sensitivity (Se), positive predictive value (PPV), and accuracy (F 1 ) were found to improve even for lower filter order. The same technique was extended to evaluate maternal QRS detector (MQRS) and found to yield satisfactory maternal heart rate (MHR) results.

  2. Differentiating hypertrophic cardiomyopathy from athlete's heart: An electrocardiographic and echocardiographic approach.

    PubMed

    Grazioli, Gonzalo; Usín, Domingo; Trucco, Emilce; Sanz, Maria; Montserrat, Silvia; Vidal, Bàrbara; Gutierrez, Josep; Canal, Ramon; Brugada, Josep; Mont, Lluis; Sitges, Marta

    2016-01-01

    Differential diagnosis of hypertrophic cardiomyopathy (HCM) vs athlete's heart is challenging in individuals with mild-moderate left-ventricular hypertrophy. This study aimed to assess ECG and echocardiographic parameters proposed for the differential diagnosis of HCM. The study included 75 men in three groups: control (n=30), "gray zone" athletes with interventricular septum (IVS) measuring 13-15mm (n=25) and HCM patients with IVS of 13-18mm (n=20). The most significant differences were found in relative septal thickness (RST), calculated as the ratio of 2 x IVS to left ventricle end-diastolic diameter (LV-EDD) (0.37, 0.51, 0.71, respectively; p<0.01) and in spatial QRS-T angle as visually estimated (9.8, 33.6, 66.2, respectively; p<0.01). The capacity for differential HCM diagnosis of each of the 5 criteria was assessed using the area under the curve (AUC), as follows: LV-EDD<54 (0.60), family history (0.61), T-wave inversion (TWI) (0.67), spatial QRS-T angle>45 (0.75) and RST>0.54 (0.92). Pearson correlation between spatial QRS-T angle>45 and TWI was 0.76 (p 0.01). The combination of spatial QRS-T angle>45 and RST>0.54 for diagnosis of HCM had an AUC of 0.79. The best diagnostic criteria for HCM was RST>0.54. The spatial QRS-T angle>45 did not add sensitivity if TWI was present. No additional improvement in differential diagnosis was obtained by combining parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. [Shock shape representation of sinus heart rate based on cloud model].

    PubMed

    Yin, Wenfeng; Zhao, Jie; Chen, Tiantian; Zhang, Junjian; Zhang, Chunyou; Li, Dapeng; An, Baijing

    2014-04-01

    The present paper is to analyze the trend of sinus heart rate RR interphase sequence after a single ventricular premature beat and to compare it with the two parameters, turbulence onset (TO) and turbulence slope (TS). Based on the acquisition of sinus rhythm concussion sample, we in this paper use a piecewise linearization method to extract its linear characteristics, following which we describe shock form with natural language through cloud model. In the process of acquisition, we use the exponential smoothing method to forecast the position where QRS wave may appear to assist QRS wave detection, and use template to judge whether current cardiac is sinus rhythm. And we choose some signals from MIT-BIH Arrhythmia Database to detect whether the algorithm is effective in Matlab. The results show that our method can correctly detect the changing trend of sinus heart rate. The proposed method can achieve real-time detection of sinus rhythm shocks, which is simple and easily implemented, so that it is effective as a supplementary method.

  4. A 300-mV 220-nW event-driven ADC with real-time QRS detection for wearable ECG sensors.

    PubMed

    Zhang, Xiaoyang; Lian, Yong

    2014-12-01

    This paper presents an ultra-low-power event-driven analog-to-digital converter (ADC) with real-time QRS detection for wearable electrocardiogram (ECG) sensors in wireless body sensor network (WBSN) applications. Two QRS detection algorithms, pulse-triggered (PUT) and time-assisted PUT (t-PUT), are proposed based on the level-crossing events generated from the ADC. The PUT detector achieves 97.63% sensitivity and 97.33% positive prediction in simulation on the MIT-BIH Arrhythmia Database. The t-PUT improves the sensitivity and positive prediction to 97.76% and 98.59% respectively. Fabricated in 0.13 μm CMOS technology, the ADC with QRS detector consumes only 220 nW measured under 300 mV power supply, making it the first nanoWatt compact analog-to-information (A2I) converter with embedded QRS detector.

  5. Fine-mapping, novel loci identification, and SNP association transferability in a genome-wide association study of QRS duration in African Americans.

    PubMed

    Evans, Daniel S; Avery, Christy L; Nalls, Mike A; Li, Guo; Barnard, John; Smith, Erin N; Tanaka, Toshiko; Butler, Anne M; Buxbaum, Sarah G; Alonso, Alvaro; Arking, Dan E; Berenson, Gerald S; Bis, Joshua C; Buyske, Steven; Carty, Cara L; Chen, Wei; Chung, Mina K; Cummings, Steven R; Deo, Rajat; Eaton, Charles B; Fox, Ervin R; Heckbert, Susan R; Heiss, Gerardo; Hindorff, Lucia A; Hsueh, Wen-Chi; Isaacs, Aaron; Jamshidi, Yalda; Kerr, Kathleen F; Liu, Felix; Liu, Yongmei; Lohman, Kurt K; Magnani, Jared W; Maher, Joseph F; Mehra, Reena; Meng, Yan A; Musani, Solomon K; Newton-Cheh, Christopher; North, Kari E; Psaty, Bruce M; Redline, Susan; Rotter, Jerome I; Schnabel, Renate B; Schork, Nicholas J; Shohet, Ralph V; Singleton, Andrew B; Smith, Jonathan D; Soliman, Elsayed Z; Srinivasan, Sathanur R; Taylor, Herman A; Van Wagoner, David R; Wilson, James G; Young, Taylor; Zhang, Zhu-Ming; Zonderman, Alan B; Evans, Michele K; Ferrucci, Luigi; Murray, Sarah S; Tranah, Gregory J; Whitsel, Eric A; Reiner, Alex P; Sotoodehnia, Nona

    2016-10-01

    The electrocardiographic QRS duration, a measure of ventricular depolarization and conduction, is associated with cardiovascular mortality. While single nucleotide polymorphisms (SNPs) associated with QRS duration have been identified at 22 loci in populations of European descent, the genetic architecture of QRS duration in non-European populations is largely unknown. We therefore performed a genome-wide association study (GWAS) meta-analysis of QRS duration in 13,031 African Americans from ten cohorts and a transethnic GWAS meta-analysis with additional results from populations of European descent. In the African American GWAS, a single genome-wide significant SNP association was identified (rs3922844, P = 4 × 10 -14 ) in intron 16 of SCN5A, a voltage-gated cardiac sodium channel gene. The QRS-prolonging rs3922844 C allele was also associated with decreased SCN5A RNA expression in human atrial tissue (P = 1.1 × 10 -4 ). High density genotyping revealed that the SCN5A association region in African Americans was confined to intron 16. Transethnic GWAS meta-analysis identified novel SNP associations on chromosome 18 in MYL12A (rs1662342, P = 4.9 × 10 -8 ) and chromosome 1 near CD1E and SPTA1 (rs7547997, P = 7.9 × 10 -9 ). The 22 QRS loci previously identified in populations of European descent were enriched for significant SNP associations with QRS duration in African Americans (P = 9.9 × 10 -7 ), and index SNP associations in or near SCN5A, SCN10A, CDKN1A, NFIA, HAND1, TBX5 and SETBP1 replicated in African Americans. In summary, rs3922844 was associated with QRS duration and SCN5A expression, two novel QRS loci were identified using transethnic meta-analysis, and a significant proportion of QRS-SNP associations discovered in populations of European descent were transferable to African Americans when adequate power was achieved. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions

  6. Fine-mapping, novel loci identification, and SNP association transferability in a genome-wide association study of QRS duration in African Americans

    PubMed Central

    Evans, Daniel S.; Avery, Christy L.; Nalls, Mike A.; Li, Guo; Barnard, John; Smith, Erin N.; Tanaka, Toshiko; Butler, Anne M.; Buxbaum, Sarah G.; Alonso, Alvaro; Arking, Dan E.; Berenson, Gerald S.; Bis, Joshua C.; Buyske, Steven; Carty, Cara L.; Chen, Wei; Chung, Mina K.; Cummings, Steven R.; Deo, Rajat; Eaton, Charles B.; Fox, Ervin R.; Heckbert, Susan R.; Heiss, Gerardo; Hindorff, Lucia A.; Hsueh, Wen-Chi; Isaacs, Aaron; Jamshidi, Yalda; Kerr, Kathleen F.; Liu, Felix; Liu, Yongmei; Lohman, Kurt K.; Magnani, Jared W.; Maher, Joseph F.; Mehra, Reena; Meng, Yan A.; Musani, Solomon K.; Newton-Cheh, Christopher; North, Kari E.; Psaty, Bruce M.; Redline, Susan; Rotter, Jerome I.; Schnabel, Renate B.; Schork, Nicholas J.; Shohet, Ralph V.; Singleton, Andrew B.; Smith, Jonathan D.; Soliman, Elsayed Z.; Srinivasan, Sathanur R.; Taylor, Herman A.; Van Wagoner, David R.; Wilson, James G.; Young, Taylor; Zhang, Zhu-Ming; Zonderman, Alan B.; Evans, Michele K.; Ferrucci, Luigi; Murray, Sarah S.; Tranah, Gregory J.; Whitsel, Eric A.; Reiner, Alex P.; Sotoodehnia, Nona

    2016-01-01

    The electrocardiographic QRS duration, a measure of ventricular depolarization and conduction, is associated with cardiovascular mortality. While single nucleotide polymorphisms (SNPs) associated with QRS duration have been identified at 22 loci in populations of European descent, the genetic architecture of QRS duration in non-European populations is largely unknown. We therefore performed a genome-wide association study (GWAS) meta-analysis of QRS duration in 13,031 African Americans from ten cohorts and a transethnic GWAS meta-analysis with additional results from populations of European descent. In the African American GWAS, a single genome-wide significant SNP association was identified (rs3922844, P = 4 × 10−14) in intron 16 of SCN5A, a voltage-gated cardiac sodium channel gene. The QRS-prolonging rs3922844 C allele was also associated with decreased SCN5A RNA expression in human atrial tissue (P = 1.1 × 10−4). High density genotyping revealed that the SCN5A association region in African Americans was confined to intron 16. Transethnic GWAS meta-analysis identified novel SNP associations on chromosome 18 in MYL12A (rs1662342, P = 4.9 × 10−8) and chromosome 1 near CD1E and SPTA1 (rs7547997, P = 7.9 × 10−9). The 22 QRS loci previously identified in populations of European descent were enriched for significant SNP associations with QRS duration in African Americans (P = 9.9 × 10−7), and index SNP associations in or near SCN5A, SCN10A, CDKN1A, NFIA, HAND1, TBX5 and SETBP1 replicated in African Americans. In summary, rs3922844 was associated with QRS duration and SCN5A expression, two novel QRS loci were identified using transethnic meta-analysis, and a significant proportion of QRS–SNP associations discovered in populations of European descent were transferable to African Americans when adequate power was achieved. PMID:27577874

  7. Low QRS Voltage on Presenting Electrocardiogram Predicts Multi-vessel Disease in Anterior ST-segment Elevation Myocardial Infarction.

    PubMed

    Kobayashi, Akihiro; Misumida, Naoki; Aoi, Shunsuke; Kanei, Yumiko

    Low QRS voltage was reported to predict adverse outcomes in acute myocardial infarction in the pre-thrombolytic era. However, the association between low voltage and angiographic findings has not been fully addressed. We performed a retrospective analysis of patients with anterior ST-segment elevation myocardial infarction (STEMI). Low QRS voltage was defined as either peak to peak QRS complex voltage <1.0mV in all precordial leads or <0.5mV in all limb leads. Among 190 patients, 37 patients (19%) had low voltage. Patients with low voltage had a higher rate of multi-vessel disease (MVD) (76% vs. 52%, p=0.01). Patients with low voltage were more likely to undergo coronary artery bypass grafting (CABG) during admission (11% vs. 2%, p=0.028). Low voltage was an independent predictor for MVD (OR 2.50; 95% CI 1.12 to 6.03; p=0.032). Low QRS voltage was associated with MVD and in-hospital CABG in anterior STEMI. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Tp-e Interval, Tp-e/QTc Ratio, and Fragmented QRS Are Correlated with the Severity of Liver Cirrhosis.

    PubMed

    Akboga, Mehmet Kadri; Yuksel, Mahmut; Balci, Kevser Gulcihan; Kaplan, Mustafa; Cay, Serkan; Gokbulut, Volkan; Yayla, Cagri; Ertem, Ahmet Goktug; Ayhan, Meral Akdogan; Topaloglu, Serkan; Aras, Dursun

    2017-01-01

    Arrhythmias and electrocardiographic changes are reported in several noncardiac diseases, including liver cirrhosis (LC). We intended to evaluate the interval from the peak to the end of the electrocardiographic T wave (Tp-e), Tp-e/QTc ratio, and fQRS as presumed markers of arrhythmias in LC. In this cross-sectional study, a total of 88 consecutive patients with LC according to clinical, biological, ultrasonographic, or histological criteria and 73 control subjects were enrolled. The severity of cirrhosis was classified according to Pugh-Child's classification and Model for End-Stage Liver Disease (MELD) score. Tp-e interval, Tp-e/QTc ratio, and fQRS rates were measured from the 12-lead electrocardiogram. Tp-e interval, Tp-e/QTc ratio and fQRS rates were significantly increased in parallel to the severity of LC (P < 0.001, P < 0.001, and P = 0.003, respectively). In correlation analysis, Pugh-Child stage showed a significantly positive correlation with Tp-e interval (r = 0.462, P < 0.001), QTc interval (r = 0.373, P < 0.001), Tp-e/QTc ratio (r = 0.352, P < 0.001), and fQRS (r = 0.407, P < 0.001). Furthermore, Tp-e interval (r = 0.414, P < 0.001) and Tp-e/QTc ratio (r = 0.426, P< 0.001) had significant positive correlation with MELD score. Our study demonstrated that Tp-e interval, Tp-e/QTc ratios, and fQRS rates were significantly increased in parallel to the severity of LC. Thus, these findings may implicate that Tp-e interval, Tp-e/QTc ratio, and fQRS may be novel and useful indicators for prediction of arrhythmias in LC. © 2016 Wiley Periodicals, Inc.

  9. QRS-fragmentation: Case report and review of the literature.

    PubMed

    Illescas-González, Edgar; Araiza-Garaygordobil, Diego; Sierra Lara, Jorge Daniel; Ramirez-Salazar, Aristoteles; Sierra-Fernández, Carlos; Alexanderson-Rosas, Erick

    Fragmentation of QRS complex (QRSf) is an easily evaluable, non-invasive electrocardiographic parameter that represents depolarisation anomalies and has been associated with several adverse outcomes, such as sudden death, fibrosis, arrhythmic burden, and a worse prognosis in different conditions, including coronary artery disease (CAD). The case is presented of a 69-year old male referred due to symptoms of chronic stable angina. His electrocardiogram showed sinus rhythm, absence of Q waves, but the presence of QRSf in the inferior leads and V4-V6. A Tc-99 myocardial perfusion SPECT scan revealed a fixed perfusion defect in the inferolateral region, corresponding to the finding of QRSf. QRSf is an easily valuable electrocardiographic marker with relative sensitivity, but poor specificity. Its routine clinical application could contribute to an increase in the suspicion of coronary artery disease. The presence of fragmented QRS represents distortion of signal conduction and depolarisation, which is related to myocardial scar or myocardial fibrosis. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  10. Field programmable gate array based fuzzy neural signal processing system for differential diagnosis of QRS complex tachycardia and tachyarrhythmia in noisy ECG signals.

    PubMed

    Chowdhury, Shubhajit Roy

    2012-04-01

    The paper reports of a Field Programmable Gate Array (FPGA) based embedded system for detection of QRS complex in a noisy electrocardiogram (ECG) signal and thereafter differential diagnosis of tachycardia and tachyarrhythmia. The QRS complex has been detected after application of entropy measure of fuzziness to build a detection function of ECG signal, which has been previously filtered to remove power line interference and base line wander. Using the detected QRS complexes, differential diagnosis of tachycardia and tachyarrhythmia has been performed. The entire algorithm has been realized in hardware on an FPGA. Using the standard CSE ECG database, the algorithm performed highly effectively. The performance of the algorithm in respect of QRS detection with sensitivity (Se) of 99.74% and accuracy of 99.5% is achieved when tested using single channel ECG with entropy criteria. The performance of the QRS detection system has been compared and found to be better than most of the QRS detection systems available in literature. Using the system, 200 patients have been diagnosed with an accuracy of 98.5%.

  11. Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Kulecz, Walter B.; DePalma, Jude L.; Feiveson, Alan H.; Wilson, John S.; Rahman, M. Atiar; Bungo, Michael W.

    2004-01-01

    Several studies have shown that diminution of the high-frequency (HF; 150-250 Hz) components present within the central portion of the QRS complex of an electrocardiogram (ECG) is a more sensitive indicator for the presence of myocardial ischemia than are changes in the ST segments of the conventional low-frequency ECG. However, until now, no device has been capable of displaying, in real time on a beat-to-beat basis, changes in these HF QRS ECG components in a continuously monitored patient. Although several software programs have been designed to acquire the HF components over the entire QRS interval, such programs have involved laborious off-line calculations and postprocessing, limiting their clinical utility. We describe a personal computer-based ECG software program developed recently at the National Aeronautics and Space Administration (NASA) that acquires, analyzes, and displays HF QRS components in each of the 12 conventional ECG leads in real time. The system also updates these signals and their related derived parameters in real time on a beat-to-beat basis for any chosen monitoring period and simultaneously displays the diagnostic information from the conventional (low-frequency) 12-lead ECG. The real-time NASA HF QRS ECG software is being evaluated currently in multiple clinical settings in North America. We describe its potential usefulness in the diagnosis of myocardial ischemia and coronary artery disease.

  12. Real-Time, High-Frequency QRS Electrocardiograph

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; DePalma, Jude L.; Moradi, Saeed

    2003-01-01

    An electronic system that performs real-time analysis of the low-amplitude, high-frequency, ordinarily invisible components of the QRS portion of an electrocardiographic signal in real time has been developed. Whereas the signals readily visible on a conventional electrocardiogram (ECG) have amplitudes of the order of a millivolt and are characterized by frequencies <100 Hz, the ordinarily invisible components have amplitudes in the microvolt range and are characterized by frequencies from about 150 to about 250 Hz. Deviations of these high-frequency components from a normal pattern can be indicative of myocardial ischemia or myocardial infarction

  13. Summation and Cancellation Effects on QRS and ST-Segment Changes Induced by Simultaneous Regional Myocardial Ischemia.

    PubMed

    Vives-Borrás, Miquel; Jorge, Esther; Amorós-Figueras, Gerard; Millán, Xavier; Arzamendi, Dabit; Cinca, Juan

    2018-01-01

    Simultaneous ischemia in two myocardial regions is a potentially lethal clinical condition often unrecognized whose corresponding electrocardiographic (ECG) patterns have not yet been characterized. Thus, this study aimed to determine the QRS complex and ST-segment changes induced by concurrent ischemia in different myocardial regions elicited by combined double occlusion of the three main coronary arteries. For this purpose, 12 swine were randomized to combination of 5-min single and double coronary artery occlusion: Group 1: left Circumflex (LCX) and right (RCA) coronary arteries ( n = 4); Group 2: left anterior descending artery (LAD) and LCX ( n = 4) and; Group 3: LAD and RCA ( n = 4). QRS duration and ST-segment displacement were measured in 15-lead ECG. As compared with single occlusion, double LCX+RCA blockade induced significant QRS widening of about 40 ms in nearly all ECG leads and magnification of the ST-segment depression in leads V1-V3 (maximal 228% in lead V3, p < 0.05). In contrast, LAD+LCX or LAD+RCA did not induce significant QRS widening and markedly attenuated the ST-segment elevation in precordial leads (maximal attenuation of 60% in lead V3 in LAD+LCX and 86% in lead V5 in LAD+RCA, p < 0.05). ST-segment elevation in leads V7-V9 was a specific sign of single LCX occlusion. In conclusion, concurrent infero-lateral ischemia was associated with a marked summation effect of the ECG changes previously elicited by each single ischemic region. By contrast, a cancellation effect on ST-segment changes with no QRS widening was observed when the left anterior descending artery was involved.

  14. Detection of segments with fetal QRS complex from abdominal maternal ECG recordings using support vector machine

    NASA Astrophysics Data System (ADS)

    Delgado, Juan A.; Altuve, Miguel; Nabhan Homsi, Masun

    2015-12-01

    This paper introduces a robust method based on the Support Vector Machine (SVM) algorithm to detect the presence of Fetal QRS (fQRS) complexes in electrocardiogram (ECG) recordings provided by the PhysioNet/CinC challenge 2013. ECG signals are first segmented into contiguous frames of 250 ms duration and then labeled in six classes. Fetal segments are tagged according to the position of fQRS complex within each one. Next, segment features extraction and dimensionality reduction are obtained by applying principal component analysis on Haar-wavelet transform. After that, two sub-datasets are generated to separate representative segments from atypical ones. Imbalanced class problem is dealt by applying sampling without replacement on each sub-dataset. Finally, two SVMs are trained and cross-validated using the two balanced sub-datasets separately. Experimental results show that the proposed approach achieves high performance rates in fetal heartbeats detection that reach up to 90.95% of accuracy, 92.16% of sensitivity, 88.51% of specificity, 94.13% of positive predictive value and 84.96% of negative predictive value. A comparative study is also carried out to show the performance of other two machine learning algorithms for fQRS complex estimation, which are K-nearest neighborhood and Bayesian network.

  15. [The relationship between fragmented QRS complex and coronary collateral circulation in patients with chronic total occlusion lesion without prior myocardial infarction].

    PubMed

    Gu, X J; Shan, S J; Liu, Z Z; Jin, G Z; Hu, Z Y; Zhu, L L; Zhang, J

    2017-04-24

    Objective: To explore the relationship between fragmented QRS complex(fQRS) and coronary collateral circulation(CCC) in patients with chronic total occlusion(CTO)lesion without prior myocardial infarction. Methods: This retrospective study analyzed 238 consecutive patients with CTO lesion in one of the major coronary arteries from May 2014 to October 2015 in our department. Patients were divided into poor CCC group (grade 0 and 1, 58 cases) and good CCC group(grade 2 and 3, 180 cases) based on Rentrop's classification of CCC. The fQRS was defined as the presence of an additional R wave or notching of R or S wave or the presence of fragmentation in two contiguous electrocardiogram leads corresponding to a major coronary artery territory. Multivariate logistic regression was used to analyze the relationship between CCC and fQRS on electrocardiogram. Results: Compared with good CCC group, patients in poor CCC group had older age((65.2±8.9)years old vs. (60.3±10.1) years old, P =0.03), higher plasma glucose ((7.22±3.00) mmol/L vs.(6.31±1.83)mmol/L, P =0.04), and lower left ventricular ejection fraction ((45.2±11.4)% vs. (51.2±13.5)%, P =0.02). None of patients had Rentrop grade 0, the presence of fQRS on ECG in patients with Rentrop grade 1, grade 2, and grade 3 CCC was 69.0% (40/58), 48.6% (35/72) , and 19.4% (21/108), respectively ( P <0.01). The presence of fQRS were higher in poor CCC group than in good CCC group (69.0%(40/58)vs. 31.1%(56/180), P <0.01), and number of leads with fQRS were higher in poor CCC group than in good CCC group (3(0, 4)vs.0(0, 3), P <0.01). Multivariate logistic regression analysis demonstrated that poor CCC growth in patients with CTO lesion without prior myocardial infarction was independently related to the presence of fQRS ( OR =3.659, 95% CI 1.619-8.217, P <0.01). Conclusion: Poor CCC in patients with CTO lesion without prior myocardial infarction is independently related to the presence of fQRS on electrocardiogram.

  16. Ventricular Tachycardia or not? An Unexpected Reason of Wide QRS Complex Tachycardia in a Young Healthy Man: Sodium Bicarbonate.

    PubMed

    Eyuboglu, Mehmet

    2016-10-01

    Ventricular tachycardia (VT) is life-threatening subgroup of wide QRS complex tachycardia (WCT). VT is usually associated with structural heart diseases, but it can occur in the absence of any cardiovascular diseases. Adverse cardiac effect of sodium bicarbonate in healthy subjects is not well described. A 30-year-old healthy man with excessive intake of sodium bicarbonate-related VT is presented. He was using sodium bicarbonate during last 2 months to lose weight. He has no risk factors and any cardiovascular or systemic diseases. After intravenous administration of amiodarone, tachycardia ended and his rhythm converted to sinus rhythm with normal electrocardiogram. Patient is asymptomatic, and no VT was observed without any medications at 1 year of follow-up.

  17. [Electrocardiographic diagnosis: when QRS is wide.

    PubMed

    Conti, Matilde; Bregani, Enrico Rino

    2018-04-01

    Differential diagnosis of one or more wide QRS complexes on an electrocardiogram under emergency conditions takes into account three main sets of clinical conditions: ventricular pre-excitation, aberrant conduction and ventricular beats and it is based on the morphological analysis of the ECG and patient's anamnestic data. Several criteria can facilitate the differential diagnosis and if properly used and integrated with clinic data they can achieve good diagnostic accuracy in most cases. In this review several criteria based on evidence and literature are presented, paying attention in recognizing some morphologic pathways that can be used in emergency room and allow a correct ECG assessment.

  18. A real time QRS detection using delay-coordinate mapping for the microcontroller implementation.

    PubMed

    Lee, Jeong-Whan; Kim, Kyeong-Seop; Lee, Bongsoo; Lee, Byungchae; Lee, Myoung-Ho

    2002-01-01

    In this article, we propose a new algorithm using the characteristics of reconstructed phase portraits by delay-coordinate mapping utilizing lag rotundity for a real-time detection of QRS complexes in ECG signals. In reconstructing phase portrait the mapping parameters, time delay, and mapping dimension play important roles in shaping of portraits drawn in a new dimensional space. Experimentally, the optimal mapping time delay for detection of QRS complexes turned out to be 20 ms. To explore the meaning of this time delay and the proper mapping dimension, we applied a fill factor, mutual information, and autocorrelation function algorithm that were generally used to analyze the chaotic characteristics of sampled signals. From these results, we could find the fact that the performance of our proposed algorithms relied mainly on the geometrical property such as an area of the reconstructed phase portrait. For the real application, we applied our algorithm for designing a small cardiac event recorder. This system was to record patients' ECG and R-R intervals for 1 h to investigate HRV characteristics of the patients who had vasovagal syncope symptom and for the evaluation, we implemented our algorithm in C language and applied to MIT/BIH arrhythmia database of 48 subjects. Our proposed algorithm achieved a 99.58% detection rate of QRS complexes.

  19. Evaluation of heart rate variability indices using a real-time handheld remote ECG monitor.

    PubMed

    Singh, Swaroop S; Carlson, Barbara W; Hsiao, Henry S

    2007-12-01

    Studies on retrospective electrocardiogram (ECG) recordings of patients during cardiac arrest have shown significant changes in heart rate variability (HRV) indices prior to the onset of cardiac arrhythmia. The early detection of these changes in HRV indices increases the chances for a successful medical intervention by increasing the response time window. A portable, handheld remote ECG monitor designed in this research detects the QRS complex and calculates short-term HRV indices in real-time. The QRS detection of the ECG recordings of subjects from the MIT-Arrhythmia database yielded a mean sensitivity of 99.34% and a specificity of 99.31%. ECG recordings from normal subjects and subjects with congestive heart failure were used to identify the differences in HRV indices. An increase in heart rate, high-frequency spectral power (HFP), total spectral power, the ratio of HFP to low-frequency spectral power (LFP), and a decrease in root mean square sum of RR differences were observed. No difference was found on comparison of the standard deviation of normal to normal interval between adjacent R-waves, LFP, and very-low-frequency spectral power. Based on these, additional analytical calculations could be made to provide early warnings of impending cardiac conditions.

  20. Month-to-month and year-to-year reproducibility of high frequency QRS ECG signals

    NASA Technical Reports Server (NTRS)

    Batdorf, Niles J.; Feiveson, Alan H.; Schlegel, Todd T.

    2004-01-01

    High frequency electrocardiography analyzing the entire QRS complex in the frequency range of 150 to 250 Hz may prove useful in the detection of coronary artery disease, yet the long-term stability of these waveforms has not been fully characterized. Therefore, we prospectively investigated the reproducibility of the root mean squared voltage, kurtosis, and the presence versus absence of reduced amplitude zones in signal averaged 12-lead high frequency QRS recordings acquired in the supine position one month apart in 16 subjects and one year apart in 27 subjects. Reproducibility of root mean squared voltage and kurtosis was excellent over these time intervals in the limb leads, and acceptable in the precordial leads using both the V-lead and CR-lead derivations. The relative error of root mean squared voltage was 12% month-to-month and 16% year-to-year in the serial recordings when averaged over all 12 leads. Reduced amplitude zones were also reproducible up to a rate of 87% and 81%, respectively, for the month-to-month and year-to-year recordings. We conclude that 12-lead high frequency QRS electrocardiograms are sufficiently reproducible for clinical use.

  1. Month-to-Month and Year-to-Year Reproducibility of High Frequency QRS ECG signals

    NASA Technical Reports Server (NTRS)

    Batdorf, Niles; Feiveson, Alan H.; Schlegel, Todd T.

    2006-01-01

    High frequency (HF) electrocardiography analyzing the entire QRS complex in the frequency range of 150 to 250 Hz may prove useful in the detection of coronary artery disease, yet the long-term stability of these waveforms has not been fully characterized. We therefore prospectively investigated the reproducibility of the root mean squared (RMS) voltage, kurtosis, and the presence versus absence of reduced amplitude zones (RAzs) in signal averaged 12-lead HF QRS recordings acquired in the supine position one month apart in 16 subjects and one year apart in 27 subjects. Reproducibility of RMS voltage and kurtosis was excellent over these time intervals in the limb leads, and acceptable in the precordial leads using both the V-lead and CR-lead derivations. The relative error of RMS voltage was 12% month-to-month and 16% year-to-year in the serial recordings when averaged over all 12 leads. RAzs were also reproducible at a rate of up to 87% and 8 1 %, respectively, for the month-to-month and year-to-year recordings. We conclude that 12-lead HF QRS electrocardiograms are sufficiently reproducible for clinical use.

  2. Atrial fibrillation with wide QRS tachycardia and undiagnosed Wolff-Parkinson-White syndrome: diagnostic and therapeutic dilemmas in a pediatric patient.

    PubMed

    Panduranga, Prashanth; Al-Farqani, Abdullah; Al-Rawahi, Najib

    2012-11-01

    A 10-year-old girl presented to the emergency department of a regional hospital with 1 episode of generalized tonic-clonic seizures. Postictal monitoring followed by a 12-lead electrocardiogram showed fast atrial fibrillation with intermittent wide QRS regular tachycardia. Immediately following this, her rhythm changed to wide QRS irregular tachycardia without hemodynamic compromise. She was suspected to have ventricular tachycardia and was treated with intravenous amiodarone with cardioversion to sinus rhythm. Subsequent electrocardiogram in sinus rhythm showed typical features of manifest Wolff-Parkinson-White (WPW) accessory pathway. This case illustrates the diagnostic and therapeutic dilemmas in patients with atrial fibrillation, wide QRS tachycardia, and undiagnosed WPW syndrome with antidromic conduction of atrial arrhythmias through the accessory pathway. Furthermore, this case demonstrates that undiagnosed wide QRS tachycardias need to be treated with drugs acting on the accessory pathway, thus keeping in mind underlying WPW syndrome as a possibility to avoid potentially catastrophic events.

  3. QRS Score at Presentation Electrocardiogram Is Correlated With Infarct Size and Mortality in ST-Segment Elevation Myocardial Infarction Patients Undergoing Primary Percutaneous Coronary Intervention.

    PubMed

    Shiomi, Hiroki; Kosuge, Masami; Morimoto, Takeshi; Watanabe, Hiroki; Taniguchi, Tomohiko; Nakatsuma, Kenji; Toyota, Toshiaki; Yamamoto, Erika; Shizuta, Satoshi; Tada, Tomohisa; Furukawa, Yutaka; Nakagawa, Yoshihisa; Ando, Kenji; Kadota, Kazushige; Kimura, Kazuo; Kimura, Takeshi

    2017-07-25

    In ST-segment elevation myocardial infarction (STEMI), QRS score at presentation ECG may reflect the progression of infarction and facilitate prediction of the degree of myocardial salvage achieved by reperfusion therapy.Methods and Results:Admission electrocardiogram (ECG) was studied in 2,607 patients with STEMI undergoing primary percutaneous coronary intervention (PCI) within 24 h of symptom onset. Patients were classified into 3 groups according to QRS score: low (0-3, n=1,227), intermediate (4-7, n=810), and high (≥8, n=570). An increase of infarct size estimated by median peak creatine phosphokinase was observed as QRS score increased (low score, 1,836 IU/L; inter-quartile range (IQR), 979-3,190 IU/L; intermediate score, 2,488 IU/L; IQR, 1,126-4,640 IU/L; high score, 3,454 IU/L; IQR, 1,759-5,639 IU/L; P<0.001). Higher QRS score was associated with higher long-term mortality (low, intermediate, and high score, 15.6%, 19.7%, and 23.7% at 5 years, respectively; log-rank P<0.001). The positive relationship of QRS score with mortality was consistently seen when stratified by infarct location. The association of high QRS score with increased mortality was most remarkably seen in patients with early (≤2 h) presentation (low, intermediate, and high score: 16.7%, 16.6%, and 28.1% at 5 years, respectively; log-rank P<0.001). Higher QRS score at presentation ECG was associated with larger infarct size, and higher long-term mortality in patients with STEMI undergoing primary PCI. QRS score appears to be important in the early risk stratification for STEMI.

  4. Pulmonary Right Ventricular Resynchronization in Congenital Heart Disease: Acute Improvement in Right Ventricular Mechanics and Contraction Efficiency.

    PubMed

    Janoušek, Jan; Kovanda, Jan; Ložek, Miroslav; Tomek, Viktor; Vojtovič, Pavel; Gebauer, Roman; Kubuš, Peter; Krejčíř, Miroslav; Lumens, Joost; Delhaas, Tammo; Prinzen, Frits

    2017-09-01

    Electromechanical discoordination may contribute to long-term pulmonary right ventricular (RV) dysfunction in patients after surgery for congenital heart disease. We sought to evaluate changes in RV function after temporary RV cardiac resynchronization therapy. Twenty-five patients aged median 12.0 years after repair of tetralogy of Fallot and similar lesions were studied echocardiographically (n=23) and by cardiac catheterization (n=5) after primary repair (n=4) or after surgical RV revalvulation for significant pulmonary regurgitation (n=21). Temporary RV cardiac resynchronization therapy was applied in the presence of complete right bundle branch block by atrial-synchronized RV free wall pacing in complete fusion with spontaneous ventricular depolarization using temporary electrodes. The q-RV interval at the RV free wall pacing site (mean 77.2% of baseline QRS duration) confirmed pacing from a late activated RV area. RV cardiac resynchronization therapy carried significant decrease in QRS duration ( P <0.001) along with elimination of the right bundle branch block QRS morphology, increase in RV filling time ( P =0.002), pulmonary artery velocity time integral ( P =0.006), and RV maximum +dP/dt ( P <0.001), and decrease in RV index of myocardial performance ( P =0.006). RV mechanical synchrony improved: septal-to-lateral RV mechanical delay decreased ( P <0.001) and signs of RV dyssynchrony pattern were significantly abolished. RV systolic stretch fraction reflecting the ratio of myocardial stretching and contraction during systole diminished ( P =0.001). In patients with congenital heart disease and right bundle branch block, RV cardiac resynchronization therapy carried multiple positive effects on RV mechanics, synchrony, and contraction efficiency. © 2017 American Heart Association, Inc.

  5. Real-time, high frequency QRS electrocardiograph with reduced amplitude zone detection

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T. (Inventor); DePalma, Jude L. (Inventor); Moradi, Saeed (Inventor)

    2009-01-01

    Real time cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed in real time in a useful form on a computer screen or monitor. The monitor displays the high frequency data from the QRS complex in units of microvolts, juxtaposed with a display of conventional ECG data in units of millivolts or microvolts. The high frequency data are analyzed for their root mean square (RMS) voltage values and the discrete RMS values and related parameters are displayed in real time. The high frequency data from the QRS complex are analyzed with imbedded algorithms to determine the presence or absence of reduced amplitude zones, referred to herein as ''RAZs''. RAZs are displayed as ''go, no-go'' signals on the computer monitor. The RMS and related values of the high frequency components are displayed as time varying signals, and the presence or absence of RAZs may be similarly displayed over time.

  6. Heart Disease in Women

    MedlinePlus

    ... United States, 1 in 4 women dies from heart disease. The most common cause of heart disease in both men and women is narrowing ... the blood vessels that supply blood to the heart itself. This is called coronary artery disease, and ...

  7. Are classic predictors of voltage valid in cardiac amyloidosis? A contemporary analysis of electrocardiographic findings.

    PubMed

    Sperry, Brett W; Vranian, Michael N; Hachamovitch, Rory; Joshi, Hariom; McCarthy, Meghann; Ikram, Asad; Hanna, Mazen

    2016-07-01

    Low voltage electrocardiography (ECG) coupled with increased ventricular wall thickness is the hallmark of cardiac amyloidosis. However, patient characteristics influencing voltage in the general population, including bundle branch block, have not been evaluated in amyloid heart disease. A retrospective analysis was performed of patients with newly diagnosed cardiac amyloidosis from 2002 to 2014. ECG voltage was calculated using limb (sum of QRS complex in leads I, II and III) and precordial (Sokolow: S in V1 plus R in V5-V6) criteria. The associations between voltage and clinical variables were tested using multivariable linear regression. A Cox model assessed the association of voltage with mortality. In 389 subjects (transthyretin ATTR 186, light chain AL 203), 30% had conduction delay (QRS >120ms). In those with narrow QRS, 68% met low limb, 72% low Sokolow and 57% both criteria, with lower voltages found in AL vs ATTR. LV mass index as well as other typical factors that impact voltage (age, sex, race, hypertension, BSA, and smoking) in the general population were not associated with voltage in this cardiac amyloidosis cohort. Patients with LBBB and IVCD had similar voltages when compared to those with narrow QRS. Voltage was significantly associated with mortality (p<0.001 for both criteria) after multivariable adjustment. Classic predictors of ECG voltage in the general population are not valid in cardiac amyloidosis. In this cohort, the prevalence estimates of ventricular conduction delay and low voltage are higher than previously reported. Voltage predicts mortality after multivariable adjustment. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Depolarization changes during acute myocardial ischemia by evaluation of QRS slopes: standard lead and vectorial approach.

    PubMed

    Romero, Daniel; Ringborn, Michael; Laguna, Pablo; Pahlm, Olle; Pueyo, Esther

    2011-01-01

    Diagnosis and risk stratification of patients with acute coronary syndromes can be improved by adding information from the depolarization phase (QRS complex) to the conventionally used ST-T segment changes. In this study, ischemia-induced changes in the main three slopes of the QRS complex, upward ( ℑ(US)) and downward ( ℑ(DS) ) slopes of the R wave as well as the upward ( ℑ(TS)) slope of the terminal S wave, were evaluated as to represent a robust measure of pathological changes within the depolarization phase. From ECG recordings both in a resting state (control recordings) and during percutaneous coronary intervention (PCI)-induced transmural ischemia, we developed a method for quantification of ℑ(US), ℑ(DS), and ℑ(TS) that incorporates dynamic ECG normalization so as to improve the sensitivity in the detection of ischemia-induced changes. The same method was also applied on leads obtained by projection of QRS loops onto their dominant directions. We show that ℑ(US), ℑ(DS), and ℑ(TS) present high stability in the resting state, thus providing a stable reference for ischemia characterization. Maximum relative factors of change ( ℜ(ℑ)) during PCI were found in leads derived from the QRS loop, reaching 10.5 and 13.7 times their normal variations in the control for ℑ(US) and ℑ(DS), respectively. For standard leads, the relative factors of change were 6.01 and 9.31. The ℑ(TS) index presented a similar behavior to that of ℑ(DS). The timing for the occurrence of significant changes in ℑ(US) and ℑ(DS) varied with lead, ranging from 30 s to 2 min after initiation of coronary occlusion. In the present ischemia model, relative ℑ(DS) changes were smaller than ST changes in most leads, however with only modest correlation between the two indices, suggesting they present different information about the ischemic process. We conclude that QRS slopes offer a robust tool for evaluating depolarization changes during myocardial ischemia.

  9. Are the QRS duration and ST depression cut-points from the Seattle criteria too conservative?

    PubMed

    Dunn, Tim; Abdelfattah, Ramy; Aggarwal, Sonya; Pickham, David; Hadley, David; Froelicher, Victor

    2015-01-01

    Screening athletes with ECGs is aimed at identifying "at-risk" individuals who may have a cardiac condition predisposing them to sudden cardiac death. The Seattle criteria highlight QRS duration greater than 140 ms and ST segment depression in two or more leads greater than 50 μV as two abnormal ECG patterns associated with sudden cardiac death. High school, college, and professional athletes underwent 12 lead ECGs as part of routine pre-participation physicals. Prevalence of prolonged QRS duration was measured using cut-points of 120, 125, 130, and 140 ms. ST segment depression was measured in all leads except leads III, aVR, and V1 with cut-points of 25 μV and 50 μV. Between June 2010 and November 2013, 1595 participants including 297 (167 male, mean age 16.2) high school athletes, 1016 (541 male, mean age 18.8) college athletes, and 282 (mean age 26.6) male professional athletes underwent screening with an ECG. Only 3 athletes (0.2%) had a QRS duration greater than 125 ms. ST segment depression in two or more leads greater than 50 μV was uncommon (0.8%), while the prevalence of ST segment depression in two or more leads increased to 4.5% with a cut-point of 25 μV. Changing the QRS duration cut-point to 125 ms would increase the sensitivity of the screening ECG, without a significant increase in false-positives. However, changing the ST segment depression cut-point to 25 μV would lead to a significant increase in false-positives and would therefore not be justified. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Sympathetic neural activation does not mediate heart rate variability during repeated brief umbilical cord occlusions in near-term fetal sheep.

    PubMed

    Lear, Christopher A; Galinsky, Robert; Wassink, Guido; Mitchell, Clinton J; Davidson, Joanne O; Westgate, Jennifer A; Bennet, Laura; Gunn, Alistair J

    2016-03-01

    Changes in fetal heart rate variability (FHRV) and ST segment elevation (measured as the T/QRS ratio) are used to evaluate fetal adaptation to labour. The sympathetic nervous system (SNS) is an important contributor to FHRV under healthy normoxic conditions, and is critical for rapid support of blood pressure during brief labour-like asphyxia. However, although it has been assumed that SNS activity contributes to FHRV during labour; this has never been tested, and it is unclear whether the SNS contributes to the rapid increase in T/QRS ratio during brief asphyxia. Thirteen chronically instrumented fetal sheep at 0.85 of gestation received either chemical sympathectomy with 6-hydroxydopamine (6-OHDA; n = 6) or sham treatment (control; n = 7), followed 4-5 days later by 2 min episodes of complete umbilical cord occlusion repeated every 5 min for up to 4 h, or until mean arterial blood pressure fell to <20 mmHg for two successive occlusions. FHRV was decreased before occlusions in the 6-OHDA group (P < 0.05) and 2-4.5 h during recovery after occlusions (P < 0.05) compared to the control group. During each occlusion there was a rapid increase in T/QRS ratio. Between successive occlusions the T/QRS ratio rapidly returned to baseline, and FHRV increased above baseline in both groups (P < 0.05), with no significant effect of sympathectomy on FHRV or T/QRS ratio. In conclusion, these data show that SNS activity does not mediate the increase in FHRV between repeated episodes of brief umbilical cord occlusion or the transient increase in T/QRS ratio during occlusions. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.

  11. Une tachycardie à QRS large mal tolérée chez un nourrisson

    PubMed Central

    Affangla, Désiré Alain; Leye, Mohamed; Simo, Angèle Wabo; D’Almeida, Franck; Sarr, Thérèse Yandé; Phiri, Adamson; Kane, Adama

    2017-01-01

    Les tachycardies à QRS large mal tolérées du nourrisson posent le problème de leur diagnostic et de la prise en charge en urgence. Nous rapportons un cas de tachycardie à QRS large chez un nourrisson de 35 jours reçu pour détresse cardio-circulatoire. Le cœur était morphologiquement normal à l’échographie cardiaque Doppler. Un traitement par une dose charge d’Amiodarone n’a pas permis de réduire cette tachycardie. Un retour en rythme sinusal a été obtenu après cardioversion par un défibrillateur externe semi-automatique type Lifeline. Un traitement d’entretien par Amiodarone per os est institué et le patient est en rythme sinusal à 03 mois. PMID:28904685

  12. Living with heart disease and angina

    MedlinePlus

    ... medlineplus.gov/ency/patientinstructions/000576.htm Living with heart disease and angina To use the sharing features on ... pain and reduce your risks from heart disease. Heart Disease and Angina CHD is a narrowing of the ...

  13. Electrocardiogram voltage discordance: Interpretation of low QRS voltage only in the precordial leads.

    PubMed

    Kim, Diana H; Verdino, Ralph J

    To define clinical correlates of low voltage isolated to precordial leads on the surface electrocardiogram (ECG). Low voltage (V) on the ECG is defined as QRS V<5mm in all limb leads and <10mm in all precordial leads. The diagnostic use of ECGs with low voltage isolated to the precordial leads with normal limb lead voltages is unclear. Twelve-lead ECGs with QRS V>5mm in one or more limb leads and <10mm in all precordial leads were collected. Associated clinical conditions were determined from clinical data, echocardiograms, and chest radiographs. Low precordial voltage was found in 256 of 150,000 ECGs (~0.2%). 50.4% of patients had discordant ECGs that correlated with classic etiologies, with a higher incidence of LV dilation in those with classic etiologies than those without. Low precordial voltage is associated with classic etiologies and LV dilation. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Absence of Rapid Propagation through the Purkinje Network as a Potential Cause of Line Block in the Human Heart with Left Bundle Branch Block.

    PubMed

    Okada, Jun-Ichi; Washio, Takumi; Nakagawa, Machiko; Watanabe, Masahiro; Kadooka, Yoshimasa; Kariya, Taro; Yamashita, Hiroshi; Yamada, Yoko; Momomura, Shin-Ichi; Nagai, Ryozo; Hisada, Toshiaki; Sugiura, Seiryo

    2018-01-01

    Background: Cardiac resynchronization therapy is an effective device therapy for heart failure patients with conduction block. However, a problem with this invasive technique is the nearly 30% of non-responders. A number of studies have reported a functional line of block of cardiac excitation propagation in responders. However, this can only be detected using non-contact endocardial mapping. Further, although the line of block is considered a sign of responders to therapy, the mechanism remains unclear. Methods: Herein, we created two patient-specific heart models with conduction block and simulated the propagation of excitation based on a cellmodel of electrophysiology. In one model with a relatively narrow QRS width (176 ms), we modeled the Purkinje network using a thin endocardial layer with rapid conduction. To reproduce a wider QRS complex (200 ms) in the second model, we eliminated the Purkinje network, and we simulated the endocardial mapping by solving the inverse problem according to the actual mapping system. Results: We successfully observed the line of block using non-contact mapping in the model without the rapid propagation of excitation through the Purkinje network, although the excitation in the wall propagated smoothly. This model of slow conduction also reproduced the characteristic properties of the line of block, including dense isochronal lines and fractionated local electrocardiograms. Further, simulation of ventricular pacing from the lateral wall shifted the location of the line of block. By contrast, in the model with the Purkinje network, propagation of excitation in the endocardial map faithfully followed the actual propagation in the wall, without showing the line of block. Finally, switching the mode of propagation between the two models completely reversed these findings. Conclusions: Our simulation data suggest that the absence of rapid propagation of excitation through the Purkinje network is the major cause of the functional line

  15. Quick detection of QRS complexes and R-waves using a wavelet transform and K-means clustering.

    PubMed

    Xia, Yong; Han, Junze; Wang, Kuanquan

    2015-01-01

    Based on the idea of telemedicine, 24-hour uninterrupted monitoring on electrocardiograms (ECG) has started to be implemented. To create an intelligent ECG monitoring system, an efficient and quick detection algorithm for the characteristic waveforms is needed. This paper aims to give a quick and effective method for detecting QRS-complexes and R-waves in ECGs. The real ECG signal from the MIT-BIH Arrhythmia Database is used for the performance evaluation. The method proposed combined a wavelet transform and the K-means clustering algorithm. A wavelet transform is adopted in the data analysis and preprocessing. Then, based on the slope information of the filtered data, a segmented K-means clustering method is adopted to detect the QRS region. Detection of the R-peak is based on comparing the local amplitudes in each QRS region, which is different from other approaches, and the time cost of R-wave detection is reduced. Of the tested 8 records (total 18201 beats) from the MIT-BIH Arrhythmia Database, an average R-peak detection sensitivity of 99.72 and a positive predictive value of 99.80% are gained; the average time consumed detecting a 30-min original signal is 5.78s, which is competitive with other methods.

  16. Prognostic Factors in Severe Chagasic Heart Failure

    PubMed Central

    Costa, Sandra de Araújo; Rassi, Salvador; Freitas, Elis Marra da Madeira; Gutierrez, Natália da Silva; Boaventura, Fabiana Miranda; Sampaio, Larissa Pereira da Costa; Silva, João Bastista Masson

    2017-01-01

    Background Prognostic factors are extensively studied in heart failure; however, their role in severe Chagasic heart failure have not been established. Objectives To identify the association of clinical and laboratory factors with the prognosis of severe Chagasic heart failure, as well as the association of these factors with mortality and survival in a 7.5-year follow-up. Methods 60 patients with severe Chagasic heart failure were evaluated regarding the following variables: age, blood pressure, ejection fraction, serum sodium, creatinine, 6-minute walk test, non-sustained ventricular tachycardia, QRS width, indexed left atrial volume, and functional class. Results 53 (88.3%) patients died during follow-up, and 7 (11.7%) remained alive. Cumulative overall survival probability was approximately 11%. Non-sustained ventricular tachycardia (HR = 2.11; 95% CI: 1.04 - 4.31; p<0.05) and indexed left atrial volume ≥ 72 mL/m2 (HR = 3.51; 95% CI: 1.63 - 7.52; p<0.05) were the only variables that remained as independent predictors of mortality. Conclusions The presence of non-sustained ventricular tachycardia on Holter and indexed left atrial volume > 72 mL/m2 are independent predictors of mortality in severe Chagasic heart failure, with cumulative survival probability of only 11% in 7.5 years. PMID:28443956

  17. Comparison of the QRS Complex, ST-Segment, and T-Wave Among Patients with Left Bundle Branch Block with and without Acute Myocardial Infarction.

    PubMed

    Dodd, Kenneth W; Elm, Kendra D; Smith, Stephen W

    2016-07-01

    The modified Sgarbossa criteria have been validated as a rule for diagnosis of acute coronary occlusion (ACO) in left bundle branch block (LBBB). However, no analysis has been done on differences in the QRS complex, T-wave, or ST-segment concordance of < 1 mm in the derivation or validation studies. Furthermore, there was no comparison of patients with acute myocardial infarction (AMI) but without ACO (i.e., non-ST-elevation myocardial infarction [non-STEMI]) to patients with ACO or without AMI (no MI). We compare findings involving the QRS amplitude, ST-segment morphology, ST-concordance < 1 mm, and T-waves in patients with LBBB with ACO, non-STEMI, and no MI. Retrospectively, emergency department patients were identified with LBBB and ischemic symptoms but no MI, with angiographically proven ACO, and with non-STEMI. ACO, non-STEMI, and no MI groups consisted of 33, 24, and 105 patients. The sum of the maximum deflection of the QRS amplitude across all leads (ΣQRS) was smaller in patients with ACO than those without ACO (101.5 mm vs. 132.5 mm; p < 0.0001) and a cutoff of ΣQRS < 90 mm was 92% specific. For ACO, non-concave ST-segment morphology was 91% specific, any ST concordance ≥ 1 mm was 95% specific, and any ST concordance ≥ 0.5 mm was 94% sensitive. For non-STEMI, terminal T-wave concordance, analogous to biphasic T-waves, was moderately sensitive at 79%. We found differences in QRS amplitude, ST-segment morphology, and T-waves between patients with LBBB and ACO, non-STEMI, and no MI. However, none of these criteria outperformed the modified Sgarbossa criteria for diagnosis of ACO in LBBB. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Chronic Heart Failure: Contemporary Diagnosis and Management

    PubMed Central

    Ramani, Gautam V.; Uber, Patricia A.; Mehra, Mandeep R.

    2010-01-01

    Chronic heart failure (CHF) remains the only cardiovascular disease with an increasing hospitalization burden and an ongoing drain on health care expenditures. The prevalence of CHF increases with advancing life span, with diastolic heart failure predominating in the elderly population. Primary prevention of coronary artery disease and risk factor management via aggressive blood pressure control are central in preventing new occurrences of left ventricular dysfunction. Optimal therapy for CHF involves identification and correction of potentially reversible precipitants, target-dose titration of medical therapy, and management of hospitalizations for decompensation. The etiological phenotype, absolute decrease in left ventricular ejection fraction and a widening of QRS duration on electrocardiography, is commonly used to identify patients at increased risk of progression of heart failure and sudden death who may benefit from prophylactic implantable cardioverter-defibrillator placement with or without cardiac resynchronization therapy. Patients who transition to advanced stages of disease despite optimal traditional medical and device therapy may be candidates for hemodynamically directed approaches such as a left ventricular assist device; in selected cases, listing for cardiac transplant may be warranted. PMID:20118395

  19. Cardiac resynchronization therapy with His bundle pacing as a method of treatment of chronic heart failure in patients with permanent atrial fibrillation and left bundle branch block.

    PubMed

    Boczar, Krzysztof; Sławuta, Agnieszka; Ząbek, Andrzej; Dębski, Maciej; Gajek, Jacek; Lelakowski, Jacek; Małecka, Barbara

    CRT is a therapeutic option for patients with heart failure, sinus rhythm, prolonged QRS complex duration and reduced ejection fraction. We present a case of 71-year-old woman with dilated cardiomyopathy, NYHA functional class III and AF. We implanted CRT combined with direct His-bundle pacing. The indication for such a therapy was a left bundle branch block with a QRS complex of 178ms and a left ventricular EF of 15%, left ventricular end-diastolic diameter (LVEDD) of 75mm. After 8months of follow-up the LVEDD was 60mm with EF 35-40%. Copyright © 2017. Published by Elsevier Inc.

  20. Accurate derivation of heart rate variability signal for detection of sleep disordered breathing in children.

    PubMed

    Chatlapalli, S; Nazeran, H; Melarkod, V; Krishnam, R; Estrada, E; Pamula, Y; Cabrera, S

    2004-01-01

    The electrocardiogram (ECG) signal is used extensively as a low cost diagnostic tool to provide information concerning the heart's state of health. Accurate determination of the QRS complex, in particular, reliable detection of the R wave peak, is essential in computer based ECG analysis. ECG data from Physionet's Sleep-Apnea database were used to develop, test, and validate a robust heart rate variability (HRV) signal derivation algorithm. The HRV signal was derived from pre-processed ECG signals by developing an enhanced Hilbert transform (EHT) algorithm with built-in missing beat detection capability for reliable QRS detection. The performance of the EHT algorithm was then compared against that of a popular Hilbert transform-based (HT) QRS detection algorithm. Autoregressive (AR) modeling of the HRV power spectrum for both EHT- and HT-derived HRV signals was achieved and different parameters from their power spectra as well as approximate entropy were derived for comparison. Poincare plots were then used as a visualization tool to highlight the detection of the missing beats in the EHT method After validation of the EHT algorithm on ECG data from the Physionet, the algorithm was further tested and validated on a dataset obtained from children undergoing polysomnography for detection of sleep disordered breathing (SDB). Sensitive measures of accurate HRV signals were then derived to be used in detecting and diagnosing sleep disordered breathing in children. All signal processing algorithms were implemented in MATLAB. We present a description of the EHT algorithm and analyze pilot data for eight children undergoing nocturnal polysomnography. The pilot data demonstrated that the EHT method provides an accurate way of deriving the HRV signal and plays an important role in extraction of reliable measures to distinguish between periods of normal and sleep disordered breathing (SDB) in children.

  1. Electrocardiographic Findings in Brazilian Adults without Heart Disease: ELSA-Brasil.

    PubMed

    Pinto, Marcelo Martins; Brant, Luisa C C; Padilha-da-Silva, José Luiz; Foppa, Murilo; Lotufo, Paulo A; Mill, José Geraldo; Vasconcelo-Silva, Paulo R; Almeida, Maria da Conceição C; Barreto, Sandhi Maria; Ribeiro, Antônio Luiz Pinho

    2017-11-01

    The electrocardiogram (ECG) is widely used in population-based studies. However, there are few studies on electrocardiographic findings in Latin America and in Brazil. The Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) comprised 15,105 participants (35-74 years) from six Brazilian capitals. To describe electrocardiographic findings in Brazilian adults without heart disease, stratified by sex, age and race/skin color. Cross-sectional study with baseline data of 11,094 adults (44.5% men) without heart disease from ELSA-Brasil. The ECGs were recorded with the Burdick Atria 6100 machine and stored at the Pyramis System. ECG analysis was automatically performed using the Glasgow University software. A descriptive analysis of heart rate (HR), P, QRS and T waves' duration, PR and QT intervals, and P, R and T axes was performed. After stratification by sex, race/color and age, the groups were compared by the Wilcoxon and Kruskal-Wallis test at a significance level of 5%. Linear regression models were used to evaluate the behavior of electrocardiographic parameters over age. Major electrocardiographic abnormalities defined by the Minnesota code were manually revised. Medians values of the electrocardiographic parameters were different between men and women: HR 63 vs. 66 bpm, PR 164 vs.158 ms, QT corrected 410 vs. 421 ms, QRS duration 92 vs. 86 ms, P-wave duration 112 vs. 108 ms, P-wave axis 54 vs. 57 degrees, R-wave axis 35 vs. 39 degrees, T-wave axis 39 vs. 45 degrees (p < 0.001 for all). The 2nd and the 98th percentiles of each variable were also obtained, and graphs were constructed to illustrate the behavior of the electrocardiographic findings over age of participants stratified by sex and race/skin color. The values for the electrocardiographic measurements herein described can be used as reference for Brazilian adults free of heart disease, stratified by sex. Our results suggest that self-reported race/skin color have no significant influence on

  2. Electrocardiographic Findings in Brazilian Adults without Heart Disease: ELSA-Brasil

    PubMed Central

    Pinto Filho, Marcelo Martins; Brant, Luisa C. C.; Padilha-da-Silva, José Luiz; Foppa, Murilo; Lotufo, Paulo A.; Mill, José Geraldo; Vasconcelo-Silva, Paulo R.; Almeida, Maria da Conceição C.; Barreto, Sandhi Maria; Ribeiro, Antônio Luiz Pinho

    2017-01-01

    Background The electrocardiogram (ECG) is widely used in population-based studies. However, there are few studies on electrocardiographic findings in Latin America and in Brazil. The Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) comprised 15,105 participants (35-74 years) from six Brazilian capitals. Objectives To describe electrocardiographic findings in Brazilian adults without heart disease, stratified by sex, age and race/skin color. Methods Cross-sectional study with baseline data of 11,094 adults (44.5% men) without heart disease from ELSA-Brasil. The ECGs were recorded with the Burdick Atria 6100 machine and stored at the Pyramis System. ECG analysis was automatically performed using the Glasgow University software. A descriptive analysis of heart rate (HR), P, QRS and T waves’ duration, PR and QT intervals, and P, R and T axes was performed. After stratification by sex, race/color and age, the groups were compared by the Wilcoxon and Kruskal-Wallis test at a significance level of 5%. Linear regression models were used to evaluate the behavior of electrocardiographic parameters over age. Major electrocardiographic abnormalities defined by the Minnesota code were manually revised. Results Medians values of the electrocardiographic parameters were different between men and women: HR 63 vs. 66 bpm, PR 164 vs.158 ms, QT corrected 410 vs. 421 ms, QRS duration 92 vs. 86 ms, P-wave duration 112 vs. 108 ms, P-wave axis 54 vs. 57 degrees, R-wave axis 35 vs. 39 degrees, T-wave axis 39 vs. 45 degrees (p < 0.001 for all). The 2nd and the 98th percentiles of each variable were also obtained, and graphs were constructed to illustrate the behavior of the electrocardiographic findings over age of participants stratified by sex and race/skin color. Conclusions The values for the electrocardiographic measurements herein described can be used as reference for Brazilian adults free of heart disease, stratified by sex. Our results suggest that self-reported race

  3. [Study on effect of aqueous extracts from aconite on "dose-time-toxicity" relationships in mice hearts].

    PubMed

    Feng, Qun; Li, Xiao-yu; Luan, Yong-fu; Sun, Sai-nan; Sun, Rong

    2015-03-01

    To study the effect of single administration of aqueous extracts from aconite on "dose-toxicity" relationship and "time-toxicity" relationship of mice hearts, through changes in electrocardiogram (ECG) and serum biochemical indexes. Mice were grouped according to different drug doses and time points, and orally administered with water extracts from aconite for once to observe the changes of mice ECG before and after the administration, calculate visceral indexes heart, liver and kidney, and detect levels of CK, LDH, BNP and CTn-I in serum. According to the "time-toxicity" relationship study, at 5 min after oral administration with aqueous extracts from aconite in mice, the heart rate of mice began rising, reached peak at 60 min and then slowly reduced; QRS, R amplitude, T duration and amplitude and QT interval declined at 5 min, reduced to the bottom at 60 min and then gradually elevated. The levels of CK, LDH, BNP and CTn-I in serum elevated at 5 min and reached the peak at 60 min, with no significant change in ratios of organs to body at different time points. On the basis of the "dose-toxicity" relationship, with the increase in single dose of aqueous extracts from aconite, the heart rate of mice. QRS, T duration and amplitude and QT interval declined gradually, and levels of CK, LDH, BNP and CTn-I in serum slowly elevated, with a certain dose dependence and no significant change in ratios of organs to body in mice. Single oral administration of different doses of aqueous extracts from aconite could cause different degrees of heart injury at different time points, with a certain dose dependence. Its peak time of toxicity is at 60 min after the administration of aqueous extracts from aconite.

  4. Clinical and Electrocardiographic Characteristics of Electrical Storms Due to Monomorphic Ventricular Tachycardia Refractory to Intravenous Amiodarone.

    PubMed

    Murata, Hiroshige; Miyauchi, Yasushi; Hayashi, Meiso; Iwasaki, Yu-Ki; Yodogawa, Kenji; Ueno, Akira; Hayashi, Hiroshi; Tsuboi, Ippei; Uetake, Shunsuke; Takahashi, Kenta; Yamamoto, Teppei; Maruyama, Mitsunori; Akutsu, Koichi; Yamamoto, Takeshi; Kobayashi, Yoshinori; Tanaka, Keiji; Atarashi, Hirotsugu; Katoh, Takao; Shimizu, Wataru

    2015-01-01

    Few reports are available on the characteristics of electrical storms of ventricular tachycardia (VT storm) refractory to intravenous (IV) amiodarone. IV-amiodarone was administered to 60 patients with ventricular tachyarrhythmia between 2007 and 2012. VT storms, defined as 3 or more episodes of VT within 24 h, occurred in 30 patients (68±12 years, 7 female), with 12 having ischemic and 18 non-ischemic heart disease. We compared the clinical and electrocardiographic characteristics of the patients with VT storms suppressed by IV-amiodarone (Effective group) to those of patients not affected by the treatment (Refractory group). IV-amiodarone could not control recurrence of VT in 9 patients (30%). The Refractory group comprised 5 patients with acute myocardial infarctions. Although there was no difference in the VT cycle length, the QRS duration of both the VT and premature ventricular contractions (PVCs) followed by VT was narrower in the Refractory group than in the Effective group (140±30 vs. 178±25 ms, P<0.01; 121±14 vs. 179±22 ms, P<0.01). In the Refractory group, additional administration of IV-mexiletine and/or Purkinje potential-guided catheter ablation was effective. IV-amiodarone-refractory VT exhibited a relatively narrow QRS tachycardia. The narrow triggering PVCs, suggesting a Purkinje fiber origin, may be treated by additional IV-mexiletine and endocardial catheter ablation.

  5. Prognostic significance of inverse spatial QRS-T angle circadian pattern in myocardial infarction survivors.

    PubMed

    Giannopoulos, Georgios; Dilaveris, Polychronis; Batchvarov, Velislav; Synetos, Andreas; Hnatkova, Katerina; Gatzoulis, Konstantinos; Malik, Marek; Stefanadis, Christodoulos

    2009-01-01

    We investigated the predictive value of the spatial QRS-T angle (QRSTA) circadian variation in myocardial infarction (MI) patients. Analyzing 24-hour recordings (SEER MC, GE Marquette) from 151 MI patients (age 63 +/- 12.7), the QRSTA was computed in derived XYZ leads. QRS-T angle values were compared between daytime and night time. The end point was cardiac death or life-threatening ventricular arrhythmia in 1 year. Overall, QRSTA was slightly higher during the day vs. the night (91 degrees vs. 87 degrees, P = .005). However, 33.8% of the patients showed an inverse diurnal QRSTA variation (higher values at night), which was correlated to the outcome (P = .001, odds ratio 6.7). In multivariate analysis, after entering all factors exhibiting univariate trend towards significance, inverse QRSTA circadian pattern remained significant (P = .036). Inverse QRSTA circadian pattern was found to be associated with adverse outcome (22.4%) in MI patients, whereas a normal pattern was associated (96%) with a favorable outcome.

  6. Atrial Premature Depolarization-Induced Changes in QRS and T Wave Morphology on Resting Electrocardiograms in Horses.

    PubMed

    Broux, B; De Clercq, D; Decloedt, A; Van Der Vekens, N; Verheyen, T; Ven, S; Pardon, B; van Loon, G

    2016-07-01

    The electrocardiographic differentiation between atrial (APDs) and ventricular (VPDs) premature depolarizations is important. P wave prematurity and normal QRS and T wave morphology generally are used as discriminating criteria for APDs. The aim of this study was to determine whether P, Q, R, S, and T wave amplitude, PQ interval, QRS and P wave duration and P and T wave morphology differ between APDs and sinus beats. To determine the relationship between the RR coupling interval and the change in S wave amplitude between sinus beats and APDs. Case-control study. From a modified base-apex configuration of 30 horses with APDs at rest, sinus beat and APD associated preceding RR interval, P, PQ and QRS duration and P, R, S, and T wave amplitudes were measured. Linear mixed models and logistic regression were used to determine the effect of APDs on the ECG variables studied. In comparison to sinus beats, APDs were associated with a significant (P < .001) change in P amplitude (-0.03 ± 0.01 mV) and increase in S (0.20 ± 0.02 mV) and T (0.08 ± 0.03 mV) amplitude. PQ (-20.3 ± 5.2 ms) and RR (-519 ± 14 ms) interval and P duration (-21.1 ± 3.0 ms) decreased (P < .001). APDs were significantly associated with a singular positive P wave (OR: 11.0, P < .001) and were more likely to have a monophasic positive T wave (OR: 9.2, P < .001). A smaller RR coupling interval was associated with an increased relative difference in S amplitude (P < .01). Atrial premature depolarizations may lead to changes in QRS and T wave morphology. Knowledge of these changes is important to avoid interpreting certain APDs as VPDs. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  7. Onset of decreased heart work is correlated with increased heart rate and shortened QT interval in high-carbohydrate fed overweight rats.

    PubMed

    Durak, Aysegul; Olgar, Yusuf; Tuncay, Erkan; Karaomerlioglu, Irem; Kayki Mutlu, Gizem; Arioglu Inan, Ebru; Altan, Vecdi Melih; Turan, Belma

    2017-11-01

    Mechanical activity of the heart is adversely affected in metabolic syndrome (MetS) characterized by increased body mass and marked insulin resistance. Herein, we examined the effects of high carbohydrate intake on cardiac function abnormalities by evaluating in situ heart work, heart rate, and electrocardiograms (ECGs) in rats. MetS was induced in male Wistar rats by adding 32% sucrose to drinking water for 22-24 weeks and was confirmed by insulin resistance, increased body weight, increased blood glucose and serum insulin, and increased systolic and diastolic blood pressures in addition to significant loss of left ventricular integrity and increased connective tissue around myofibrils. Analysis of in situ ECG recordings showed a markedly shortened QT interval and decreased QRS amplitude with increased heart rate. We also observed increased oxidative stress and decreased antioxidant defense characterized by decreases in serum total thiol level and attenuated paraoxonase and arylesterase activities. Our data indicate that increased heart rate and a shortened QT interval concomitant with higher left ventricular developed pressure in response to β-adrenoreceptor stimulation as a result of less cyclic AMP release could be regarded as a natural compensation mechanism in overweight rats with MetS. In addition to the persistent insulin resistance and obesity associated with MetS, one should consider the decreased heart work, increased heart rate, and shortened QT interval associated with high carbohydrate intake, which may have more deleterious effects on the mammalian heart.

  8. [Wide QRS tachycardia preceded by pacemaker spikes].

    PubMed

    Romero, M; Aranda, A; Gómez, F J; Jurado, A

    2014-04-01

    The differential diagnosis and therapeutic management of wide QRS tachycardia preceded by pacemaker spike is presented. The pacemaker-mediated tachycardia, tachycardia fibrillo-flutter in patients with pacemakers, and runaway pacemakers, have a similar surface electrocardiogram, but respond to different therapeutic measures. The tachycardia response to the application of a magnet over the pacemaker could help in the differential diagnosis, and in some cases will be therapeutic, as in the case of a tachycardia-mediated pacemaker. Although these conditions are diagnosed and treated in hospitals with catheterization laboratories using the application programmer over the pacemaker, patients presenting in primary care clinic and emergency forced us to make a diagnosis and treat the haemodynamically unstable patient prior to referral. Copyright © 2012 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  9. Peak oxygen uptake, ventilatory efficiency and QRS-duration predict event free survival in patients late after surgical repair of tetralogy of Fallot.

    PubMed

    Müller, Jan; Hager, Alfred; Diller, Gerhard-Paul; Derrick, Graham; Buys, Roselien; Dubowy, Karl-Otto; Takken, Tim; Orwat, Stefan; Inuzuka, Ryo; Vanhees, Luc; Gatzoulis, Michael; Giardini, Alessandro

    2015-10-01

    Patients with repaired tetralogy of Fallot (ToF) have an increased long-term risk of cardiovascular morbidity and mortality. Risk stratification in this population is difficult. Initial evidence suggests that cardiopulmonary exercise testing (CPET) may be helpful to risk-stratify patients with repaired ToF. We studied 875 patients after surgical repair for ToF (358 females, age 25.5 ± 11.7 year, range 7-75 years) who underwent CPET between 1999 and 2009. During a mean follow-up of 4.1 ± 2.6 years after CPET, 30 patients (3.4%) died or had sustained ventricular tachycardia (VT). 225 patients (25.7%) had other cardiac related events (emergency admission, surgery, or catheter interventions). On multivariable Cox regression-analysis, %predicted peak oxygen uptake (V˙O2 %) (p=0.001), resting QRS duration (p=0.030) and age (p<0.001) emerged as independent predictors of mortality or sustained VT. Patients with a peak V˙O2 ≤ 65% of predicted and a resting QRS duration ≥ 170 ms had a 11.4-fold risk of death or sustained VT. Ventilatory efficiency expressed as V˙E/V˙CO2 slope (p<0.001), peak V˙O2 % (p=.001), QRS duration (p=.001) and age (p=0.046) independently predicted event free survival. V˙E/V˙CO2 slope ≥ 31.0, peak V˙O2 % ≤ 65% and QRS duration ≥ 170 ms were the cut-off points with best sensitivity and specificity to detect an unfavorable outcome. CPET is an important predictive tool that may assist in the risk stratification of patients with ToF. Subjects with a poor exercise capacity in addition to a prolonged QRS duration have a substantially increased risk for death or sustained ventricular tachycardia, as well as for cardiac-related hospitalizations. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Utility of heart rate turbulence and T-Wave alternans to assess risk for Re-admission and cardiac death in hospitalized heart failure patients.

    PubMed

    Yamada, Shinya; Yoshihisa, Akiomi; Sato, Yu; Sato, Takamasa; Kamioka, Masashi; Kaneshiro, Takashi; Oikawa, Masayoshi; Kobayashi, Atsushi; Suzuki, Hitoshi; Ishida, Takafumi; Takeishi, Yasuchika

    2018-05-18

    Heart failure (HF) patients have a higher risk of recurrent HF and cardiac death, and electrical remodeling is considered to be an important factor for HF progression. The present study aimed to validate the utility of electrocardiogram and Holter monitoring for the risk stratification of HF patients. Our study comprised 215 patients (144 males, mean age 62 years) who had been hospitalized due to acute decompensated HF. Electrocardiogram (QRS duration and QTc interval) and 24-hour Holter monitoring (heart rate variability, heart rate turbulence and T-wave alternans [TWA]) were performed in stable condition before discharge. The clinical characteristics and outcomes were then investigated. During a median follow-up period of 2.7 years, there were 83 (38.6%) cardiac events (re-hospitalization due to worsening HF [n = 51] or cardiac death [n = 32]). The patients with cardiac events had a lower turbulence slope (TS) and higher TWA compared to those without cardiac events (TS, 3.0±5.5 ms/RR vs. 5.3±5.6 ms/RR, P = 0.001; TWA, 66.1±19.6 μV vs. 54.7±15.1 μV, P < 0.001). Univariable analysis showed that TS, TWA, QRS duration, and QTc interval were associated with cardiac events (P = 0.004, P < 0.001, P = 0.037 and P = 0.024, respectively), while the multivariable analysis after the adjustment of multiple confounders showed that TS and TWA were independent predictive factors of cardiac events with a hazard ratio of 0.936 and 1.015 (95% confidence interval [CI]: 0.860-0.974, P = 0.006; and 95% CI: 1.003-1.027, p = 0.016), respectively. The measurement of TS and TWA is useful for assessing risk for re-hospitalization and cardiac death in HF patients. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  11. Development of a Multi-Channel, High Frequency QRS Electrocardiograph

    NASA Technical Reports Server (NTRS)

    DePalma, Jude L.

    2003-01-01

    With the advent of the ISS era and the potential requirement for increased cardiovascular monitoring of crewmembers during extended EVAs, NASA flight surgeons would stand to benefit from an evolving technology that allows for a more rapid diagnosis of myocardial ischemia compared to standard electrocardiography. Similarly, during the astronaut selection process, NASA flight surgeons and other physicians would also stand to benefit from a completely noninvasive technology that, either at rest or during maximal exercise tests, is more sensitive than standard ECG in identifying the presence of ischemia. Perhaps most importantly, practicing cardiologists and emergency medicine physicians could greatly benefit from such a device as it could augment (or even replace) standard electrocardiography in settings where the rapid diagnosis of myocardial ischemia (or the lack thereof) is required for proper clinical decision-making. A multi-channel, high-frequency QRS electrocardiograph is currently under development in the Life Sciences Research Laboratories at JSC. Specifically the project consisted of writing software code, some of which contained specially-designed digital filters, which will be incorporated into an existing commercial software program that is already designed to collect, plot and analyze conventional 12-lead ECG signals on a desktop, portable or palm PC. The software will derive the high-frequency QRS signals, which will be analyzed (in numerous ways) and plotted alongside of the conventional ECG signals, giving the PC-viewing clinician advanced diagnostic information that has never been available previously in all 12 ECG leads simultaneously. After the hardware and software for the advanced digital ECG monitor have been fully integrated, plans are to use the monitor to begin clinical studies both on healthy subjects and on patients with known coronary artery disease in both the outpatient and hospital settings. The ultimate goal is to get the technology

  12. Left ventricular outflow tract arrhythmias with divergent QRS morphology: mapping of different exits and ablation strategy.

    PubMed

    Reithmann, Christopher; Fiek, Michael

    2018-01-01

    Ventricular arrhythmias (VAs) from the left ventricular outflow tract (LVOT) can have multiple exits exhibiting divergent ECG features. In a series of 131 patients with VAs with LVOT origin, 10 patients presented with divergent QRS morphologies. Multisite endo- and epicardial mapping of different exit sites was performed. The earliest ventricular activity of 23 LVOT VAs in 10 patients was detected in the endocardium of the LV in 7 patients, the aortic sinuses of Valsalva (SoV) in 3 patients, the distal coronary sinus in 6 patients, the anterior interventricular vein in 3 patients, and the posterior right ventricular outflow tract (RVOT) in 4 patients. Simultaneous elimination of two divergent QRS morphologies of LVOT VAs by ablation from a single site was achieved in 5 patients (aorto-mitral continuity in 3 patients, SoV and RVOT in each 1 patient) using a mean maximum ablation energy of 46 ± 5 W. Sequential ablation from two or three different sites, including trans-pericardial and distal coronary sinus ablation in each 2 patients, led to elimination of the divergent VA QRS morphologies in the other 5 patients. During the follow-up of 28 ± 29 months, 4 of the 10 patients had recurrence of at least one LVOT VA. A 43-year-old patient with muscular dystrophy Curschmann-Steinert had recurrence of sustained LVOT VTs and died of sudden cardiac death. Multisite mapping of different exit sites of LVOT VAs can guide ablation of intramural foci but the recurrence rate after initially successful ablation was high.

  13. Continuous ECG Monitoring in Patients With Acute Coronary Syndrome or Heart Failure: EASI Versus Gold Standard.

    PubMed

    Lancia, Loreto; Toccaceli, Andrea; Petrucci, Cristina; Romano, Silvio; Penco, Maria

    2018-05-01

    The purpose of the study was to compare the EASI system with the standard 12-lead surface electrocardiogram (ECG) for the accuracy in detecting the main electrocardiographic parameters (J point, PR, QT, and QRS) commonly monitored in patients with acute coronary syndromes or heart failure. In this observational comparative study, 253 patients who were consecutively admitted to the coronary care unit with acute coronary syndrome or heart failure were evaluated. In all patients, two complete 12-lead ECGs were acquired simultaneously. A total of 6,072 electrocardiographic leads were compared (3,036 standard and 3,036 EASI). No significant differences were found between the investigate parameters of the two measurement methods, either in patients with acute coronary syndrome or in those with heart failure. This study confirmed the accuracy of the EASI system in monitoring the main ECG parameters in patients admitted to the coronary care unit with acute coronary syndrome or heart failure.

  14. Medical Tests and Procedures for Finding and Treating Heart and Blood Vessel Disease

    MedlinePlus

    ... the narrowed or blocked blood vessel. Then the balloon is inflated, opening the narrowed artery. Awire mesh tube, called a stent, may be left in place to help keep the artery open. Angioplasty may be done during a heart attack. There are many medical tests and procedures to find and treat heart ...

  15. A systematic review of prenatal screening for congenital heart disease by fetal electrocardiography.

    PubMed

    Verdurmen, Kim M J; Eijsvoogel, Noortje B; Lempersz, Carlijn; Vullings, Rik; Schroer, Christian; van Laar, Judith O E H; Oei, S Guid

    2016-11-01

    Congenital heart disease (CHD) is the most common severe congenital anomaly worldwide. Diagnosis early in pregnancy is important, but the detection rate by two-dimensional ultrasonography is only 65%-81%. To evaluate existing data on CHD and noninvasive abdominal fetal electrocardiography (ECG). A systematic review was performed through a search of the Cochrane Library, PubMed, and Embase for studies published up to April 2016 using the terms "congenital heart disease," "fetal electrocardiogram," and other similar keywords. Primary articles that described changes in fetal ECG among fetuses with CHD published in English were included. Outcomes of interest were changes in fetal ECG parameters observed for fetuses with congenital heart disease. Findings were reported descriptively. Only five studies described changes observed in the fetal electrocardiogram for fetuses with CHD, including heart rate, heart rate variability, and PR, QRS, and QT intervals. Fetal ECG reflects the intimate relationship between the cardiac nerve conduction system and the structural morphology of the heart. It seems particularly helpful in detecting the electrophysiological effects of cardiac anatomic defects (e.g. hypotrophy, hypertrophy, and conduction interruption). Fetal ECG might be a promising clinical tool to complement ultrasonography in the screening program for CHD. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  16. Programming Cardiac Resynchronization Therapy for Electrical Synchrony: Reaching Beyond Left Bundle Branch Block and Left Ventricular Activation Delay.

    PubMed

    Varma, Niraj; O'Donnell, David; Bassiouny, Mohammed; Ritter, Philippe; Pappone, Carlo; Mangual, Jan; Cantillon, Daniel; Badie, Nima; Thibault, Bernard; Wisnoskey, Brian

    2018-02-06

    QRS narrowing following cardiac resynchronization therapy with biventricular (BiV) or left ventricular (LV) pacing is likely affected by patient-specific conduction characteristics (PR, qLV, LV-paced propagation interval), making a universal programming strategy likely ineffective. We tested these factors using a novel, device-based algorithm (SyncAV) that automatically adjusts paced atrioventricular delay (default or programmable offset) according to intrinsic atrioventricular conduction. Seventy-five patients undergoing cardiac resynchronization therapy (age 66±11 years; 65% male; 32% with ischemic cardiomyopathy; LV ejection fraction 28±8%; QRS duration 162±16 ms) with intact atrioventricular conduction (PR interval 194±34, range 128-300 ms), left bundle branch block, and optimized LV lead position were studied at implant. QRS duration (QRSd) reduction was compared for the following pacing configurations: nominal simultaneous BiV (Mode I: paced/sensed atrioventricular delay=140/110 ms), BiV+SyncAV with 50 ms offset (Mode II), BiV+SyncAV with offset that minimized QRSd (Mode III), or LV-only pacing+SyncAV with 50 ms offset (Mode IV). The intrinsic QRSd (162±16 ms) was reduced to 142±17 ms (-11.8%) by Mode I, 136±14 ms (-15.6%) by Mode IV, and 132±13 ms (-17.8%) by Mode II. Mode III yielded the shortest overall QRSd (123±12 ms, -23.9% [ P <0.001 versus all modes]) and was the only configuration without QRSd prolongation in any patient. QRS narrowing occurred regardless of QRSd, PR, or LV-paced intervals, or underlying ischemic disease. Post-implant electrical optimization in already well-selected patients with left bundle branch block and optimized LV lead position is facilitated by patient-tailored BiV pacing adjusted to intrinsic atrioventricular timing using an automatic device-based algorithm. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  17. Electrocardiographic repolarization-related variables as predictors of coronary heart disease death in the women's health initiative study.

    PubMed

    Rautaharju, Pentti M; Zhang, Zhu-Ming; Vitolins, Mara; Perez, Marco; Allison, Matthew A; Greenland, Philip; Soliman, Elsayed Z

    2014-07-28

    We evaluated 25 repolarization-related ECG variables for the risk of coronary heart disease (CHD) death in 52 994 postmenopausal women from the Women's Health Initiative study. Hazard ratios from Cox regression were computed for subgroups of women with and without cardiovascular disease (CVD). During the average follow-up of 16.9 years, 941 CHD deaths occurred. Based on electrophysiological considerations, 2 sets of ECG variables with low correlations were considered as candidates for independent predictors of CHD death: Set 1, Ѳ(Tp|Tref), the spatial angle between T peak (Tp) and normal T reference (Tref) vectors; Ѳ(Tinit|Tterm), the angle between the initial and terminal T vectors; STJ depression in V6 and rate-adjusted QTp interval (QTpa); and Set 2, TaVR and TV1 amplitudes, heart rate, and QRS duration. Strong independent predictors with over 2-fold increased risk for CHD death in women with and without CVD were Ѳ(Tp|Tref) >42° from Set 1 and TaVR amplitude >-100 μV from Set 2. The risk for these CHD death predictors remained significant after multivariable adjustment for demographic/clinical factors. Other significant predictors for CHD death in fully adjusted risk models were Ѳ(Tinit|Tterm) >30°, TV1 >175 μV, and QRS duration >100 ms. Ѳ(Tp|Tref) angle and TaVR amplitude are associated with CHD mortality in postmenopausal women. The use of these measures to identify high-risk women for further diagnostic evaluation or more intense preventive intervention warrants further study. http://www.clinicaltrials.gov. Unique identifier: NCT00000611. © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  18. Heart rate turbulence predicts all-cause mortality and sudden death in congestive heart failure patients.

    PubMed

    Cygankiewicz, Iwona; Zareba, Wojciech; Vazquez, Rafael; Vallverdu, Montserrat; Gonzalez-Juanatey, Jose R; Valdes, Mariano; Almendral, Jesus; Cinca, Juan; Caminal, Pere; de Luna, Antoni Bayes

    2008-08-01

    Abnormal heart rate turbulence (HRT) has been documented as a strong predictor of total mortality and sudden death in postinfarction patients, but data in patients with congestive heart failure (CHF) are limited. The aim of this study was to evaluate the prognostic significance of HRT for predicting mortality in CHF patients in New York Heart Association (NYHA) class II-III. In 651 CHF patients with sinus rhythm enrolled into the MUSIC (Muerte Subita en Insuficiencia Cardiaca) study, the standard HRT parameters turbulence onset (TO) and slope (TS), as well as HRT categories, were assessed for predicting total mortality and sudden death. HRT was analyzable in 607 patients, mean age 63 years (434 male), 50% of ischemic etiology. During a median follow up of 44 months, 129 patients died, 52 from sudden death. Abnormal TS and HRT category 2 (HRT2) were independently associated with increased all-cause mortality (HR: 2.10, CI: 1.41 to 3.12, P <.001 and HR: 2.52, CI: 1.56 to 4.05, P <.001; respectively), sudden death (HR: 2.25, CI: 1.13 to 4.46, P = .021 for HRT2), and death due to heart failure progression (HR: 4.11, CI: 1.84 to 9.19, P <.001 for HRT2) after adjustment for clinical covariates in multivariate analysis. The prognostic value of TS for predicting total mortality was similar in various groups dichotomized by age, gender, NYHA class, left ventricular ejection fraction, and CHF etiology. TS was found to be predictive for total mortality only in patients with QRS > 120 ms. HRT is a potent risk predictor for both heart failure and arrhythmic death in patients with class II and III CHF.

  19. The electrocardiographic manifestations of athlete's heart and their association with exercise exposure.

    PubMed

    Bessem, Bram; De Bruijn, Matthijs C; Nieuwland, Wybe; Zwerver, Johannes; Van Den Berg, Maarten

    2018-05-01

    The aim of this study was to define the minimum amount of exercise per week ('current exposure') and the total amount of exercise ('lifetime exposure') needed to lead to the electrocardiographic changes fitting athlete's heart. All the pre-participation screenings (including electrocardiograms (ECGs)) from collegiate athletes performed at University Sports Medical Center in 2013 and 2014 were collected. Data on height, weight, sex, age, current sport(s) participation and lifetime sport(s) participation were collected. Current exposure was categorised into 0-3, 3-6, 6-10 and >10 hours/week. Lifetime sport exposure was divided into five categories: 0-1000, 1001-2000, 2001-3000, 3001-4000 and >4000 hours. The study population consisted of 1229 athletes (current exposure) and 1104 athletes (lifetime exposure). Current sport exposure: There was a significant increase in training-related ECG changes in the category 3-6 vs. <3 hours/week. When looking at individual parameters, we found an association with a significant difference in sinus bradycardia and QRS voltage (<3 vs. 3-6 hours/week) and first-degree AV-block (<3 vs. >10 hours/week).Lifetime sport exposure: There was an increase in training-related ECG changes that reached significance at an exposure >3000 hours. When looking at individual parameters, we found an association with a significant difference in sinus bradycardia (0-1000 vs. 2001-3000), QRS voltage (0-1000 vs. 3001-4000) and first-degree AV-block (0-1000 vs. >4000). A minimum of ≥3 hours/week of current exposure and a lifetime exposure of >3000 hours is needed to lead to the electrocardiographic changes fitting athlete's heart.

  20. Determination of heart rate variability with an electronic stethoscope.

    PubMed

    Kamran, Haroon; Naggar, Isaac; Oniyuke, Francisca; Palomeque, Mercy; Chokshi, Priya; Salciccioli, Louis; Stewart, Mark; Lazar, Jason M

    2013-02-01

    Heart rate variability (HRV) is widely used to characterize cardiac autonomic function by measuring beat-to-beat alterations in heart rate. Decreased HRV has been found predictive of worse cardiovascular (CV) outcomes. HRV is determined from time intervals between QRS complexes recorded by electrocardiography (ECG) for several minutes to 24 h. Although cardiac auscultation with a stethoscope is performed routinely on patients, the human ear cannot detect heart sound time intervals. The electronic stethoscope digitally processes heart sounds, from which cardiac time intervals can be obtained. Accordingly, the objective of this study was to determine the feasibility of obtaining HRV from electronically recorded heart sounds. We prospectively studied 50 subjects with and without CV risk factors/disease and simultaneously recorded single lead ECG and heart sounds for 2 min. Time and frequency measures of HRV were calculated from R-R and S1-S1 intervals and were compared using intra-class correlation coefficients (ICC). The majority of the indices were strongly correlated (ICC 0.73-1.0), while the remaining indices were moderately correlated (ICC 0.56-0.63). In conclusion, we found HRV measures determined from S1-S1 are in agreement with those determined by single lead ECG, and we demonstrate and discuss differences in the measures in detail. In addition to characterizing cardiac murmurs and time intervals, the electronic stethoscope holds promise as a convenient low-cost tool to determine HRV in the hospital and outpatient settings as a practical extension of the physical examination.

  1. Analysis of the High-Frequency Content in Human QRS Complexes by the Continuous Wavelet Transform: An Automatized Analysis for the Prediction of Sudden Cardiac Death.

    PubMed

    García Iglesias, Daniel; Roqueñi Gutiérrez, Nieves; De Cos, Francisco Javier; Calvo, David

    2018-02-12

    Fragmentation and delayed potentials in the QRS signal of patients have been postulated as risk markers for Sudden Cardiac Death (SCD). The analysis of the high-frequency spectral content may be useful for quantification. Forty-two consecutive patients with prior history of SCD or malignant arrhythmias (patients) where compared with 120 healthy individuals (controls). The QRS complexes were extracted with a modified Pan-Tompkins algorithm and processed with the Continuous Wavelet Transform to analyze the high-frequency content (85-130 Hz). Overall, the power of the high-frequency content was higher in patients compared with controls (170.9 vs. 47.3 10³nV²Hz -1 ; p = 0.007), with a prolonged time to reach the maximal power (68.9 vs. 64.8 ms; p = 0.002). An analysis of the signal intensity (instantaneous average of cumulative power), revealed a distinct function between patients and controls. The total intensity was higher in patients compared with controls (137.1 vs. 39 10³nV²Hz -1 s -1 ; p = 0.001) and the time to reach the maximal intensity was also prolonged (88.7 vs. 82.1 ms; p < 0.001). The high-frequency content of the QRS complexes was distinct between patients at risk of SCD and healthy controls. The wavelet transform is an efficient tool for spectral analysis of the QRS complexes that may contribute to stratification of risk.

  2. Analysis of the High-Frequency Content in Human QRS Complexes by the Continuous Wavelet Transform: An Automatized Analysis for the Prediction of Sudden Cardiac Death

    PubMed Central

    García Iglesias, Daniel; Roqueñi Gutiérrez, Nieves; De Cos, Francisco Javier; Calvo, David

    2018-01-01

    Background: Fragmentation and delayed potentials in the QRS signal of patients have been postulated as risk markers for Sudden Cardiac Death (SCD). The analysis of the high-frequency spectral content may be useful for quantification. Methods: Forty-two consecutive patients with prior history of SCD or malignant arrhythmias (patients) where compared with 120 healthy individuals (controls). The QRS complexes were extracted with a modified Pan-Tompkins algorithm and processed with the Continuous Wavelet Transform to analyze the high-frequency content (85–130 Hz). Results: Overall, the power of the high-frequency content was higher in patients compared with controls (170.9 vs. 47.3 103nV2Hz−1; p = 0.007), with a prolonged time to reach the maximal power (68.9 vs. 64.8 ms; p = 0.002). An analysis of the signal intensity (instantaneous average of cumulative power), revealed a distinct function between patients and controls. The total intensity was higher in patients compared with controls (137.1 vs. 39 103nV2Hz−1s−1; p = 0.001) and the time to reach the maximal intensity was also prolonged (88.7 vs. 82.1 ms; p < 0.001). Discussion: The high-frequency content of the QRS complexes was distinct between patients at risk of SCD and healthy controls. The wavelet transform is an efficient tool for spectral analysis of the QRS complexes that may contribute to stratification of risk. PMID:29439530

  3. Stream computing for biomedical signal processing: A QRS complex detection case-study.

    PubMed

    Murphy, B M; O'Driscoll, C; Boylan, G B; Lightbody, G; Marnane, W P

    2015-01-01

    Recent developments in "Big Data" have brought significant gains in the ability to process large amounts of data on commodity server hardware. Stream computing is a relatively new paradigm in this area, addressing the need to process data in real time with very low latency. While this approach has been developed for dealing with large scale data from the world of business, security and finance, there is a natural overlap with clinical needs for physiological signal processing. In this work we present a case study of streams processing applied to a typical physiological signal processing problem: QRS detection from ECG data.

  4. Dynamic Changes of QRS Morphology of Premature Ventricular Contractions During Ablation in the Right Ventricular Outflow Tract: A Case Report.

    PubMed

    Yue-Chun, Li; Jia-Feng, Lin; Jia-Xuan, Lin

    2015-10-01

    Electrocardiographic characteristics can be useful in differentiating between right ventricular outflow tract (RVOT) and aortic sinus cusp (ASC) ventricular arrhythmias. Ventricular arrhythmias originating from ASC, however, show preferential conduction to RVOT that may render the algorithms of electrocardiographic characteristics less reliable. Even though there are few reports describing ventricular arrhythmias with ASC origins and endocardial breakout sites of RVOT, progressive dynamic changes in QRS morphology of the ventricular arrhythmias during ablation obtained were rare.This case report describes a patient with symptomatic premature ventricular contractions of left ASC origin presenting an electrocardiogram (ECG) characteristic of right ventricular outflow tract before ablation. Pacing at right ventricular outflow tract reproduced an excellent pace map. When radiofrequency catheter ablation was applied to the right ventricular outflow tract, the QRS morphology of premature ventricular contractions progressively changed from ECG characteristics of right ventricular outflow tract origin to ECG characteristics of left ASC origin.Successful radiofrequency catheter ablation was achieved at the site of the earliest ventricular activation in the left ASC. The distance between the successful ablation site of the left ASC and the site with an excellent pace map of the RVOT was 20 mm.The ndings could be strong evidence for a preferential conduction via the myocardial bers from the ASC origin to the breakout site in the right ventricular outflow tract. This case demonstrates that ventricular arrhythmias with a single origin and exit shift may exhibit QRS morphology changes.

  5. Analysis of QRS loop changes in the beat-to-beat Vectocardiogram of ischemic patients undergoing PTCA.

    PubMed

    Correa, Raul; Laciar, Eric; Arini, Pedro; Jane, Raimon

    2009-01-01

    In the present work, we have studied dynamic changes of QRS loop in the Vectocardiogram (VCG) of 80 patients that underwent Percutaneous Transluminal Coronary Angioplasty (PTCA). The VCG was obtained for each patient using the XYZ orthogonal leads of their electrocardiographic (ECG) records acquired before, during and after PTCA procedure. In order to analyze the variations of VCG, it has been proposed in this study the following parameters a) Maximum module of the cardiac depolarization vector, b) Volume, c) and Area of vectocardiographic loop corresponding to the QRS complex of each beat, d) Maximum distance between Centroid and the Loop, e) Angle between the XY plane and the Optimum Plane, f) Relation between the Area and Perimeter. The results obtained indicate that the parameters proposed show significant statistics differences (p-value<0.05) before, during (with some exceptions at the first minute of balloon inflation) and after PTCA. We conclude that the variations observed in the proposed parameters correctly represent not only the morphological changes in the depolarization VCG but also they reflect the modifications in the levels of cardiac ischemia induced by PTCA.

  6. Reconstruction of electrocardiogram using ionic current models for heart muscles.

    PubMed

    Yamanaka, A; Okazaki, K; Urushibara, S; Kawato, M; Suzuki, R

    1986-11-01

    A digital computer model is presented for the simulation of the electrocardiogram during ventricular activation and repolarization (QRS-T waves). The part of the ventricular septum and the left ventricular free wall of the heart are represented by a two dimensional array of 730 homogeneous functional units. Ionic currents models are used to determine the spatial distribution of the electrical activities of these units at each instant of time during simulated cardiac cycle. In order to reconstruct the electrocardiogram, the model is expanded three-dimensionally with equipotential assumption along the third axis and then the surface potentials are calculated using solid angle method. Our digital computer model can be used to improve the understanding of the relationship between body surface potentials and intracellular electrical events.

  7. Measuring the electric activity of chick embryos heart through 16 bit audio card monitored by the Goldwavetm software

    NASA Astrophysics Data System (ADS)

    Silva, Dilson; Cortez, Celia Martins

    2015-12-01

    In the present work we used a high-resolution, low-cost apparatus capable of detecting waves fit inside the sound bandwidth, and the software package GoldwaveTM for graphical display, processing and monitoring the signals, to study aspects of the electric heart activity of early avian embryos, specifically at the 18th Hamburger & Hamilton stage of the embryo development. The species used was the domestic chick (Gallus gallus), and we carried out 23 experiments in which cardiographic spectra of QRS complex waves representing the propagation of depolarization waves through ventricles was recorded using microprobes and reference electrodes directly on the embryos. The results show that technique using 16 bit audio card monitored by the GoldwaveTM software was efficient to study signal aspects of heart electric activity of early avian embryos.

  8. Electrocardiogram of Clinically Healthy Mithun (Bos frontalis): Variation among Strains

    PubMed Central

    Sanyal, Sagar; Das, Pradip Kumar; Ghosh, Probal Ranjan; Das, Kinsuk; Vupru, Kezha V.; Rajkhowa, Chandan; Mondal, Mohan

    2010-01-01

    A study was conducted to establish the normal electrocardiogram in four different genetic strains of mithun (Bos frontalis). Electrocardiography, cardiac electrical axis, heart rate, rectal temperature and respiration rate were recorded in a total of 32 adult male mithun of four strains (n = 8 each). It was found that the respiration and heart rates were higher (P < .05) in Manipur than other three strains. Amplitude (P < .05) and duration of P wave and QRS complex differed (P < .01) among the strains. Mizoram strain had the highest amplitude and duration of P wave and QRS complex. On the other hand, higher (P < .05) amplitude and duration of T wave were recorded in Arunachalee and Mizoram strains. The mean electrical axis of QRS complex that were recorded for Arunachalee and Manipur strains were similar to that reported for other bovine species; whereas the electrical axis of QRS for Nagamese and Mizoram strains were more close to feline and caprine species, respectively. In conclusion, electrocardiogram of mithun revealed that the amplitude and duration of P wave, QRS complex and T wave were different among four different genetic strains of mithun and the electrical axis of QRS complex for Nagamese and Mizoram mithuns are dissimilar to bovine species. PMID:20886013

  9. Diagnostic Accuracy of Commercially Available Automated External Defibrillators.

    PubMed

    Nishiyama, Takahiko; Nishiyama, Ako; Negishi, Masachika; Kashimura, Shin; Katsumata, Yoshinori; Kimura, Takehiro; Nishiyama, Nobuhiro; Tanimoto, Yoko; Aizawa, Yoshiyasu; Mitamura, Hideo; Fukuda, Keiichi; Takatsuki, Seiji

    2015-12-01

    Although automated external defibrillators (AEDs) have contributed to a better survival of out-of-hospital cardiac arrests, there have been reports of their malfunctioning. We investigated the diagnostic accuracy of commercially available AEDs using surface ECGs of ventricular fibrillation (VF), ventricular tachycardia (VT), and supraventricular tachycardia (SVT). ECGs(VF 31, VT 48, SVT 97) were stored during electrophysiological studies and transmitted to 4 AEDs, the LifePak CR Plus (CR Plus), HeartStart FR3 (FR3), and CardioLife AED-2150 (CL2150) and -9231 (CL9231), through the pad electrode cables. For VF, the CL2150 and CL9231 advised shocks in all cases, and the CR Plus and FR3 advised shocks in all but one VF case. For VTs faster than 180 bpm, the ratios for advising shocks were 79%, 36%, 89%, and 96% for the CR Plus, FR3, CL2150, and CL9231, respectively. The FR3 and CR Plus did not advise shocks for narrow QRS SVTs, whereas the CL9231 tended to treat high-rate tachycardias faster than 180 bpm even with narrow QRS complexes. The characteristics of the shock advice for the FR3 differed from that for the CL9231 (kappa coefficient [κ]=0.479, P<0.001), and the CR Plus and CL2150 had characteristics somewhere between the 2 former AEDs (κ=0.818, P<0.001). Commercially available AEDs diagnosed VF almost always correctly. For VT and SVT diagnoses, a discrepancy was evident among the 4 investigated AEDs. The differences in the arrhythmia diagnosis algorithms for differentiating SVT from VT were thought to account for these differences. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  10. Deletion of neurturin impairs development of cholinergic nerves and heart rate control in postnatal mouse hearts.

    PubMed

    Downs, Anthony M; Jalloh, Hawa B; Prater, Kayla J; Fregoso, Santiago P; Bond, Cherie E; Hampton, Thomas G; Hoover, Donald B

    2016-05-01

    The neurotrophic factor neurturin is required for normal cholinergic innervation of adult mouse heart and bradycardic responses to vagal stimulation. Our goals were to determine effects of neurturin deletion on development of cardiac chronotropic and dromotropic functions, vagal baroreflex response, and cholinergic nerve density in nodal regions of postnatal mice. Experiments were performed on postnatal C57BL/6 wild-type (WT) and neurturin knockout (KO) mice. Serial electrocardiograms were recorded noninvasively from conscious pups using an ECGenie apparatus. Mice were treated with atenolol to evaluate and block sympathetic effects on heart rate (HR) and phenylephrine (PE) to stimulate the baroreflex. Immunohistochemistry was used to label cholinergic nerves in paraffin sections. WT and KO mice showed similar age-dependent increases in HR and decreases in PR interval between postnatal days (P) 2.5 and 21. Treatment with atenolol reduced HR significantly in WT and KO pups at P7.5. PE caused a reflex bradycardia that was significantly smaller in KO pups. Cholinergic nerve density was significantly less in nodal regions of P7.5 KO mice. We conclude that cholinergic nerves have minimal influence on developmental changes in HR and PR, QRS, and QTc intervals in mouse pups. However, cholinergic nerves mediate reflex bradycardia by 1 week postnatally. Deletion of neurturin impairs cholinergic innervation of the heart and the vagal efferent component of the baroreflex early during postnatal development. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  11. Cardiac Repolarization Abnormalities and Potential Evidence for Loss of Cardiac Sodium Currents on ECGs of Patients with Chagas' Heart Disease

    NASA Technical Reports Server (NTRS)

    Schlegel, T. T.; Medina, R.; Jugo, D.; Nunez, T. J.; Borrego, A.; Arellano, E.; Arenare, B.; DePalma, J. L.; Greco, E. C.; Starc, V.

    2007-01-01

    Some individuals with Chagas disease develop right precordial lead ST segment elevation in response to an ajmaline challenge test, and the prevalence of right bundle branch block (RBBB) is also high in Chagas disease. Because these same electrocardiographic abnormalities occur in the Brugada syndrome, which involves genetically defective cardiac sodium channels, acquired damage to cardiac sodium channels may also occur in Chagas disease. We studied several conventional and advanced resting 12-lead/derived Frank-lead ECG parameters in 34 patients with Chagas -related heart disease (mean age 39 14 years) and in 34 age-/gender-matched healthy controls. All ECG recordings were of 5-10 min duration, obtained in the supine position using high fidelity hardware/software (CardioSoft, Houston, TX). Even after excluding those Chagas patients who had resting BBBs, tachycardia and/or pathologic arrhythmia (n=8), significant differences remained in multiple conventional and advanced ECG parameters between the Chagas and control groups (n=26/group), especially in their respective QT interval variability indices, maximal spatial QRS-T angles and low frequency HRV powers (p=0.0006, p=0.0015 and p=0.0314 respectively). In relation to the issue of potential damage to cardiac sodium channels, the Chagas patients had: 1) greater than or equal to twice the incidence of resting ST segment elevation in leads V1-V3 (n=10/26 vs. n=5/26) and of both leftward (n=5/26 versus n=0/26) and rightward (n=7/26 versus n=3/26) QRS axis deviation than controls; 2) significantly increased filtered (40-250 Hz) QRS interval durations (92.1 8.5 versus 85.3 plus or minus 9.0 ms, p=0.022) versus controls; and 3) significantly decreased QT and especially JT interval durations versus controls (QT interval: 387.5 plus or minus 26.4 versus 408.9 plus or minus 34.6 ms, p=0.013; JT interval: 290.5 plus or minus 26.3 versus 314.8 plus or minus 31.3 ms; p=0.0029). Heart rates and Bazett-corrected QTc/JTc intervals

  12. Noise-tolerant instantaneous heart rate and R-peak detection using short-term autocorrelation for wearable healthcare systems.

    PubMed

    Fujii, Takahide; Nakano, Masanao; Yamashita, Ken; Konishi, Toshihiro; Izumi, Shintaro; Kawaguchi, Hiroshi; Yoshimoto, Masahiko

    2013-01-01

    This paper describes a robust method of Instantaneous Heart Rate (IHR) and R-peak detection from noisy electrocardiogram (ECG) signals. Generally, the IHR is calculated from the R-wave interval. Then, the R-waves are extracted from the ECG using a threshold. However, in wearable bio-signal monitoring systems, noise increases the incidence of misdetection and false detection of R-peaks. To prevent incorrect detection, we introduce a short-term autocorrelation (STAC) technique and a small-window autocorrelation (SWAC) technique, which leverages the similarity of QRS complex waveforms. Simulation results show that the proposed method improves the noise tolerance of R-peak detection.

  13. Electrophysiological effects of the aqueous extract of Averrhoa carambola L. leaves on the guinea pig heart.

    PubMed

    Vasconcelos, C M L; Araújo, M S; Conde-Garcia, E A

    2006-07-01

    This work aims to describe some electrophysiological changes promoted by the aqueous extract (AEx) from Averrhoa carambola leaves in guinea pig heart. The experiments were carried out on isolated heart or on right atrium-ventricle preparations. In 6 hearts, the extract induced many kinds of atrioventricular blocks (1st, 2nd, and 3rd degrees); increased the QT interval from 229+/-23 to 264+/-19 ms; increased the QRS complex duration from 27+/-3.1 to 59+/-11 ms, and depressed the cardiac rate from 136+/-17 to 89+/-14b pm. Furthermore, it decreased the conduction velocity of atrial impulse (17+/-3%); reduced the intraventricular pressure (86+/-6%), and increased the conduction time between the right atrium and the His bundle (27+/-6.5%). The conduction time from the His bundle to the right ventricle was not altered. Atropine sulfate did not change either the electrocardiographic parameters or the intraventricular pressure effects promoted by the A. carambola AEx. Based on these results, the popular use of such extracts should be avoided because it can promote electrical and mechanical changes in the normal heart.

  14. Bisphenol A exposure and cardiac electrical conduction in excised rat hearts.

    PubMed

    Posnack, Nikki Gillum; Jaimes, Rafael; Asfour, Huda; Swift, Luther M; Wengrowski, Anastasia M; Sarvazyan, Narine; Kay, Matthew W

    2014-04-01

    Bisphenol A (BPA) is used to produce polycarbonate plastics and epoxy resins that are widely used in everyday products, such as food and beverage containers, toys, and medical devices. Human biomonitoring studies have suggested that a large proportion of the population may be exposed to BPA. Recent epidemiological studies have reported correlations between increased urinary BPA concentrations and cardiovascular disease, yet the direct effects of BPA on the heart are unknown. The goal of our study was to measure the effect of BPA (0.1-100 μM) on cardiac impulse propagation ex vivo using excised whole hearts from adult female rats. We measured atrial and ventricular activation times during sinus and paced rhythms using epicardial electrodes and optical mapping of transmembrane potential in excised rat hearts exposed to BPA via perfusate media. Atrioventricular activation intervals and epicardial conduction velocities were computed using recorded activation times. Cardiac BPA exposure resulted in prolonged PR segment and decreased epicardial conduction velocity (0.1-100 μM BPA), prolonged action potential duration (1-100 μM BPA), and delayed atrioventricular conduction (10-100 μM BPA). These effects were observed after acute exposure (≤ 15 min), underscoring the potential detrimental effects of continuous BPA exposure. The highest BPA concentration used (100 μM) resulted in prolonged QRS intervals and dropped ventricular beats, and eventually resulted in complete heart block. Our results show that acute BPA exposure slowed electrical conduction in excised hearts from female rats. These findings emphasize the importance of examining BPA's effect on heart electrophysiology and determining whether chronic in vivo exposure can cause or exacerbate conduction abnormalities in patients with preexisting heart conditions and in other high-risk populations.

  15. Systematic review and meta-analysis of left ventricular endocardial pacing in advanced heart failure: Clinically efficacious but at what cost?

    PubMed

    Graham, Adam J; Providenica, Rui; Honarbakhsh, Shohreh; Srinivasan, Neil; Sawhney, Vinit; Hunter, Ross; Lambiase, Pier

    2018-04-01

    Cardiac resynchronization using a left ventricular (LV) epicardial lead placed in the coronary sinus is now routinely used in the management of heart failure patients. LV endocardial pacing is an alternative when this is not feasible, with outcomes data sparse. To review the available evidence on the efficacy and safety of endocardial LV pacing via meta-analysis. EMBASE, MEDLINE, and COCHRANE databases with the search term "endocardial biventricular pacing" or "endocardial cardiac resynchronization" or "left ventricular endocardial" or "endocardial left ventricular." Comparisons of pre-and post-QRS width, LV ejection fraction (LVEF), and New York Heart Association (NYHA) functional classification was performed, and mean differences (and respective 95% confidence interval [CI]) applied as a measurement of treatment effect. Fifteen studies, including 362 patients, were selected. During a mean follow-up of 40 ± 24.5 months, death occurred in 72 patients (11 per 100 patient-years). Significant improvements in LVEF (mean difference 7.9%, 95% CI 5-10%, P < 0.0001; I 2  = 73%), QRS width (mean difference: -41% 95% -75 to -7%; P < 0.0001; I 2  = 94%), and NYHA class (mean difference: -1.06, 95% CI -1.2 to -0.9, P < 0.0001; I 2  = 60%), (all P < 0.0001) occurred. Stroke rate was 3.3-4.2 per 100 patient-years, which is higher than equivalent heart failure trial populations and recent meta-analysis that included small case series. LV endocardial lead implantation is a potentially efficacious alternative to CS lead placement, but preliminary data suggest a potentially higher risk of stroke during follow-up when compared to the expected incidence of stroke in similar cohorts of patients. © 2018 Wiley Periodicals, Inc.

  16. ECG on the road: robust and unobtrusive estimation of heart rate.

    PubMed

    Wartzek, Tobias; Eilebrecht, Benjamin; Lem, Jeroen; Lindner, Hans-Joachim; Leonhardt, Steffen; Walter, Marian

    2011-11-01

    Modern automobiles include an increasing number of assistance systems to increase the driver's safety. This feasibility study investigated unobtrusive capacitive ECG measurements in an automotive environment. Electrodes integrated into the driving seat allowed to measure a reliable ECG in 86% of the drivers; when only (light) cotton clothing was worn by the drivers, this value increased to 95%. Results show that an array of sensors is needed that can adapt to the different drivers and sitting positions. Measurements while driving show that traveling on the highway does not distort the signal any more than with the car engine turned OFF, whereas driving in city traffic results in a lowered detection rate due to the driver's heavier movements. To enable robust and reliable estimation of heart rate, an algorithm is presented (based on principal component analysis) to detect and discard time intervals with artifacts. This, then, allows a reliable estimation of heart rate of up to 61% in city traffic and up to 86% on the highway: as a percentage of the total driving period with at least four consecutive QRS complexes.

  17. Origins location of the outflow tract ventricular arrhythmias exhibiting qrS pattern or QS pattern with a notch on the descending limb in lead V1.

    PubMed

    Lin, Cong; Zheng, Cheng; Zhou, De-Pu; Li, Xiao-Wei; Wu, Shu-Jie; Lin, Jia-Feng

    2017-05-15

    Ventricular outflow tract(VOT) ventricular arrhythmias(VAs) presenting qrS pattern or QS pattern with a notch on the descending limb in lead V1 were consistently thought of arising from the commissure between left and right coronary cusp (L-RCC) by previous studies. However, we found they could originate from other anatomic structures in VOT. This study aimed to investigate the exact origin of this kind VAs. Forty-nine patients of VOT premature ventricular contrations/ventricular tachycardia(PVCs/VT) with lead V1 presenting qrS pattern or QS pattern with a notch on the descending limb undergoing successful radiofrequency catheter ablation(RFCA) in our center were analyzed. 12-lead electrocardiogram(ECG) of these PVCs/VT were summarized. Among these PVCs/VT, 37 cases exhibited qrS morphology in lead V1, 12 cases presented QS pattern with a notch on the descending limb in the same lead. Based on the successful ablation sites, these PVCs/VT were divided into 2 groups: (1)Right ventricular outflow tract(RVOT) group (26 cases), and (2) Left ventricular outflow tract (LVOT) group(23 cases, 4 cases originating from the left coronary cusp(LCC), 2 from the right coronary cusp(RCC), 16 from the L-RCC, 1 from the area inferior to LCC(ILCC)). The ECG characteristics of each PVCs/VT were analyzed. Among these PVCs/VT, applying the precordial transitional zone index(TZ index) < 0 to predict LVOT origin was demonstrated with sensitivity of 95.65%, specificity of 96.15%, positive predicting value(PPV) of 95.65% and negative predicting value(NPV) of 96.15%. In LVOT group, further applying the r, R, m,or Rs morphology in lead I to predict L-RCC and RCC origin was demonstrated with sensitivity of 94.44%, specificity of 60.00%, PPV of 89.47% and NPV of 75.00%. Ventricular outflow tract PVCs/VT with lead V1 presenting qrS pattern or QS pattern with a notch on descending limb not only arising from L-RCC, but also RVOT, LCC, RCC and ILCC. Combining TZ index and QRS morphology in lead I

  18. Cardio-pulmonary fitness test by ultra-short heart rate variability.

    PubMed

    Aslani, Arsalan; Aslani, Amir; Kheirkhah, Jalal; Sobhani, Vahid

    2011-10-01

    It is known that exercise induces cardio-respiratory autonomic modulation. The aim of this study was to assess the cardio-pulmonary fitness by ultra-short heart rate variability. Study population was divided into 3 groups: Group-1 (n = 40) consisted of military sports man. Group-2 (n = 40) were healthy age-matched sedentary male subjects with normal body mass index [BMI = 19 - 25 kg/m(2)). Group-3 (n = 40) were healthy age-matched obese male subjects [BMI > 29 kg/m(2)). Standard deviation of normal-to-normal QRS intervals (SDNN) was recorded over 15 minutes. Bruce protocol treadmill test was used; and, maximum oxygen consumption (VO(2)max) was calculated. WHEN THE STUDY POPULATION WAS DIVIDED INTO QUARTILES OF SDNN (FIRST QUARTILE: < 60 msec; second quartile: > 60 and < 100 msec; third quartile: > 100 and <140 msec; and fourth quartile: >140 msec), progressive increase was found in VO(2)max; and, SDNN was significantly linked with estimated VO(2)max. In conclusion, the results of this study demonstrate that exercise training improves cardio-respiratory autonomic function (and increases heart rate variability). Improvement in cardio-respiratory autonomic function seems to translate into a lower rate of long term mortality. Ultra-short heart rate variability is a simple cardio-pulmonary fitness test which just requires 15 minutes, and involves no exercise such as in the treadmill or cycle test.

  19. Design of a cardiac monitor in terms of parameters of QRS complex.

    PubMed

    Chen, Zhen-cheng; Ni, Li-li; Su, Ke-ping; Wang, Hong-yan; Jiang, Da-zong

    2002-08-01

    Objective. To design a portable cardiac monitor system based on the available ordinary ECG machine and works on the basis of QRS parameters. Method. The 80196 single chip microcomputer was used as the central microprocessor and real time electrocardiac signal was collected and analyzed [correction of analysized] in the system. Result. Apart from the performance of an ordinary monitor, this machine possesses also the following functions: arrhythmia analysis, HRV analysis, alarm, freeze, and record of automatic papering. Convenient in carrying, the system is powered by AC or DC sources. Stability, low power and low cost are emphasized in the hardware design; and modularization method is applied in software design. Conclusion. Popular in usage and low cost made the portable monitor system suitable for use under simple conditions.

  20. The relationship between J waves and contact of lung cancer with the heart.

    PubMed

    Hayashi, Hideki; Wu, Qi; Horie, Minoru

    2017-09-01

    J waves result mainly from an increased density of transient outward current (I to ). Mechanical stretch to the heart activates multiple signal transduction pathways, in which I to may be involved. The purpose of this study was to test the hypothesis that mechanical contact of lung cancer with the heart may manifest J waves. We reviewed 12-lead electrocardiograms to examine whether J waves were associated with contact of lung cancer with the heart. J waves were defied as an elevation of ≥0.1 mV at the junction between QRS complex and ST segment with either notching or slurring morphology. The locational interaction between lung cancer and the heart was determined by computed tomography image. A total of 264 patients (176 men; mean 68.5 ± 10.7 years) with lung cancer were evaluated. The prevalence of J waves was 25.4% in the total population. J waves were present in 40 of 44 (90.9%) patients with the contact. In contrast, J waves were present in 25 of 220 (11.4%) patients without the contact. The sensitivity and specificity of the contact for J waves were 90.9% and 88.6%, respectively. The odds ratio of the contact with the heart to the presence of J waves was 78 (95% confidence interval 25.7-236.4). The appearance of J waves that coincided with the development of lung cancer was observed in 12 patients. The presence of J waves was associated with the contact of lung cancer with the heart. © 2017 Wiley Periodicals, Inc.

  1. A novel method for the detection of R-peaks in ECG based on K-Nearest Neighbors and Particle Swarm Optimization

    NASA Astrophysics Data System (ADS)

    He, Runnan; Wang, Kuanquan; Li, Qince; Yuan, Yongfeng; Zhao, Na; Liu, Yang; Zhang, Henggui

    2017-12-01

    Cardiovascular diseases are associated with high morbidity and mortality. However, it is still a challenge to diagnose them accurately and efficiently. Electrocardiogram (ECG), a bioelectrical signal of the heart, provides crucial information about the dynamical functions of the heart, playing an important role in cardiac diagnosis. As the QRS complex in ECG is associated with ventricular depolarization, therefore, accurate QRS detection is vital for interpreting ECG features. In this paper, we proposed a real-time, accurate, and effective algorithm for QRS detection. In the algorithm, a proposed preprocessor with a band-pass filter was first applied to remove baseline wander and power-line interference from the signal. After denoising, a method combining K-Nearest Neighbor (KNN) and Particle Swarm Optimization (PSO) was used for accurate QRS detection in ECGs with different morphologies. The proposed algorithm was tested and validated using 48 ECG records from MIT-BIH arrhythmia database (MITDB), achieved a high averaged detection accuracy, sensitivity and positive predictivity of 99.43, 99.69, and 99.72%, respectively, indicating a notable improvement to extant algorithms as reported in literatures.

  2. Cardiac conductive disturbance in patients with polycystic ovary syndrome.

    PubMed

    Huang, Jen-Hung; Tsai, Jen-Chen; Hsu, Ming-I; Chen, Yi-Jen

    2010-12-01

    Polycystic ovary syndrome (PCOS) is the most common endocrine abnormality of reproductive-aged women and increases the risk of cardiovascular disease. However, the effects of PCOS on electrocardiograms (ECGs) are not fully elucidated. The aim of this study was to evaluate the characteristics of ECGs in patients with PCOS. This study included 24 patients with PCOS and 12 patients without PCOS. The heart rate, PR interval, QRS duration, Sokolow-Lyon voltage (SV1 + RV5/6), Cornell voltage (RaVL + SV3), QT interval and QTc interval were measured in 12-lead ECGs. The QRS duration was wider in patients with PCOS than those without PCOS (91 ± 8 vs. 81 ± 10 ms, p < 0.05). The heart rate, PR interval, Sokolow-Lyon voltage, product of the QRS duration times Cornell voltage combination, QT interval, QTc interval, QT dispersion and QTc dispersion were similar between the two groups. PCOS is associated with a widening QRS duration, which may contribute to its increased cardiovascular risks.

  3. Improving pacemaker therapy in congenital heart disease: contractility and resynchronization.

    PubMed

    Karpawich, Peter P

    2015-01-01

    Designed as effective therapy for patients with symptomatic bradycardia, implantable cardiac pacemakers initially served to improve symptoms and survival. With initial applications to the elderly and those with severe myocardial disease, extended longevity was not a major concern. However, with design technology advances in leads and generators since the 1980s, pacemaker therapy is now readily applicable to all age patients, including children with congenital heart defects. As a result, emphasis and clinical interests have advanced beyond simply quantity to quality of life. Adverse cardiac effects of pacing from right ventricular apical or epicardial sites with resultant left bundle branch QRS configurations have been recognized. As a result, and with the introduction of newer catheter-delivered pacing leads, more recent studies have focused on alternative or select pacing sites such as septal, outflow tract, and para-bundle of His. This is especially important in dealing with pacemaker therapy among younger patients and those with congenital heart disease, with expected decades of artificial cardiac stimulation, in which adverse myocellular changes secondary to pacing itself have been reported. As a correlate to these alternate or select pacing sites, applications of left ventricular pacing, either via the coronary sinus, intraseptal or epicardial, alone or in combination with right ventricular pacing, have gained interest for patients with heart failure. Although cardiac resynchronization pacing has, to date, had limited clinical applications among patients with congenital heart disease, the few published reports do indicate potential benefits as a bridge to cardiac transplant. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Ventricular arrhythmias in the absence of structural heart disease.

    PubMed

    Prystowsky, Eric N; Padanilam, Benzy J; Joshi, Sandeep; Fogel, Richard I

    2012-05-15

    Ventricular arrhythmia (VA) in structurally normal hearts can be broadly considered under non-life-threatening monomorphic and life-threatening polymorphic rhythms. Monomorphic VA is classified on the basis of site of origin in the heart, and the most common areas are the ventricular outflow tracts and left ventricular fascicles. The morphology of the QRS complexes on electrocardiogram is an excellent tool to identify the site of origin of the rhythm. Although these arrhythmias are common and generally carry an excellent prognosis, rare sudden death events have been reported. Very frequent ventricular ectopy may also result in a cardiomyopathy in a minority of patients. Suppression of VA may be achieved using calcium-channel blockers, beta-adrenergic blockers, and class I or III antiarrhythmic drugs. Radiofrequency ablation has emerged as an excellent option to eliminate these arrhythmias, although certain foci including aortic cusps and epicardium may be technically challenging. Polymorphic ventricular tachycardia (VT) is rare and generally occurs in patients with genetic ion channel disorders including long QT syndrome, Brugada syndrome, catecholaminergic polymorphic VT, and short QT syndrome. Unlike monomorphic VT, these arrhythmic syndromes are associated with sudden death. While the cardiac gross morphology is normal, suggesting a structurally normal heart, abnormalities exist at the molecular level and predispose them to arrhythmias. Another fascinating area, idiopathic ventricular fibrillation and early repolarization syndrome, are undergoing research for a genetic basis. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Effect of propranolol on heart rate variability in hyperthyroidism.

    PubMed

    Tankeu, Aurel T; Azabji-Kenfack, Marcel; Nganou, Chris-Nadège; Ngassam, Eliane; Kuate-Mfeukeu, Liliane; Mba, Camille; Dehayem, Mesmin Y; Mbanya, Jean-Claude; Sobngwi, Eugene

    2018-02-22

    We aimed to determine the effect of propanolol on heart rate variability (HRV) in hyperthyroidism before antithyroid treatment. This was a before and after study, on ten patients presenting overt hyperthyroidism naïve to treatment. In each patient, a resting electrocardiogram was done followed by estimation of cardiac autonomic dysfunction during five maneuvers (Ewing battery tests). Long term HRV measurement was done using 24 h ambulatory electrocardiographic recording. This automatically provided estimation of HRV using SDNN and RMSSD index, LF, HF, and HF/LF ratio. After baseline investigations, 40 mg of propanolol was given twice a day for 3 days and same parameters were measured after 72 h of treatment. Our patients were aged 40 ± 10 years. Propanolol significantly reduced RR and HR interval (669 ms vs 763 ms and 91 vs 79 bpm; p < 0.01). QT and PR space were significantly extended (360 vs 384 ms and 133 vs 172 ms; p = 0.01). It increases QRS complex and blood pressure response to sustained handgrip but failed to modify previously decreased heart response to deep breathing. HRV parameters such as SDNN, RMSSD, LF, HF and sympathovagal balance estimate by HF/LF ratio remained unchanged. Although a significant reduction in heart excitability, propanolol failed to restore a good sympathovagal balance in hyperthyroidism. Trial registration NCT03393728 "Retrospectively registered".

  6. Dose-related ethanol intake, Cx43 and Nav1.5 remodeling: Exploring insights of altered ventricular conduction and QRS fragmentation in excessive alcohol users.

    PubMed

    Hung, Chung-Lieh; Lai, Yu-Jun; Chi, Po-Ching; Chen, Liang-Chia; Tseng, Ya-Ming; Kuo, Jen-Yuan; Lin, Cheng-I; Chen, Yao-Chang; Lin, Shing-Jong; Yeh, Hung-I

    2018-01-01

    Chronic, excessive ethanol intake has been linked with various electrical instabilities, conduction disturbances, and even sudden cardiac death, but the underlying cause for the latter is insufficiently delineated. We studied surface electrocardiography (ECG) in a community-dwelling cohort with moderate-to-heavy daily alcohol intake (grouped as >90g/day, ≤90g/day, and nonintake). Compared with nonintake, heavier alcohol users showed markedly widened QRS duration and higher prevalence of QRS fragmentation (64.3%, 50.9%, and 33.7%, respectively, χ 2 12.0, both p<0.05) on surface ECG across the 3 groups. These findings were successfully recapitulated in 14-week-old C57BL/6 mice that were chronically given a 4% or 6% alcohol diet and showed dose-related slower action potential upstroke, reduced resting membrane potential, and disorganized or decreased intraventricular conduction (all p<0.05). Immunodetection further revealed increased ventricular collagen I depots with Cx43 downregulation and remodeling, together with clustered and diminished membrane Nav1.5 distribution. Administration of Cx43 blocker (heptanol) and Nav1.5 inhibitor (tetrodotoxin) in the mice each attenuated the suppression ventricular conduction compared with nonintake mice (p<0.05). Chronic excessive alcohol ingestion is associated with dose-related phenotypic intraventricular conduction disturbances and QRS fragmentation that can be recapitulated in mice. The mechanisms may involve suppressed gap junction and sodium channel functions, together with enhanced cardiac fibrosis that may contribute to arrhythmogenesis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Photoplethysmographic imaging via spectrally demultiplexed erythema fluctuation analysis for remote heart rate monitoring

    NASA Astrophysics Data System (ADS)

    Deglint, Jason; Chung, Audrey G.; Chwyl, Brendan; Amelard, Robert; Kazemzadeh, Farnoud; Wang, Xiao Yu; Clausi, David A.; Wong, Alexander

    2016-03-01

    Traditional photoplethysmographic imaging (PPGI) systems use the red, green, and blue (RGB) broadband measurements of a consumer digital camera to remotely estimate a patients heart rate; however, these broadband RGB signals are often corrupted by ambient noise, making the extraction of subtle fluctuations indicative of heart rate difficult. Therefore, the use of narrow-band spectral measurements can significantly improve the accuracy. We propose a novel digital spectral demultiplexing (DSD) method to infer narrow-band spectral information from acquired broadband RGB measurements in order to estimate heart rate via the computation of motion- compensated skin erythema fluctuation. Using high-resolution video recordings of human participants, multiple measurement locations are automatically identified on the cheeks of an individual, and motion-compensated broadband reflectance measurements are acquired at each measurement location over time via measurement location tracking. The motion-compensated broadband reflectance measurements are spectrally demultiplexed using a non-linear inverse model based on the spectral sensitivity of the camera's detector. A PPG signal is then computed from the demultiplexed narrow-band spectral information via skin erythema fluctuation analysis, with improved signal-to-noise ratio allowing for reliable remote heart rate measurements. To assess the effectiveness of the proposed system, a set of experiments involving human motion in a front-facing position were performed under ambient lighting conditions. Experimental results indicate that the proposed system achieves robust and accurate heart rate measurements and can provide additional information about the participant beyond the capabilities of traditional PPGI methods.

  8. Heart rate, body temperature and physical activity are variously affected during insulin treatment in alloxan-induced type 1 diabetic rat.

    PubMed

    Howarth, F C; Jacobson, M; Shafiullah, M; Ljubisavljevic, M; Adeghate, E

    2011-01-01

    Diabetes mellitus is associated with a variety of cardiovascular complications including impaired cardiac muscle function. The effects of insulin treatment on heart rate, body temperature and physical activity in the alloxan (ALX)-induced diabetic rat were investigated using in vivo biotelemetry techniques. The electrocardiogram, physical activity and body temperature were recorded in vivo with a biotelemetry system for 10 days before ALX treatment, for 20 days following administration of ALX (120 mg/kg) and thereafter, for 15 days whilst rats received daily insulin. Heart rate declined rapidly after administration of ALX. Pre-ALX heart rate was 321+/-9 beats per minute, falling to 285+/-12 beats per minute 15-20 days after ALX and recovering to 331+/-10 beats per minute 5-10 days after commencement of insulin. Heart rate variability declined and PQ, QRS and QT intervals were prolonged after administration of ALX. Physical activity and body temperature declined after administration of ALX. Pre-ALX body temperature was 37.6+/-0.1 °C, falling to 37.3+/-0.1 °C 15-20 days after ALX and recovering to 37.8+/-0.1 °C 5-10 days after commencement insulin. ALX-induced diabetes is associated with disturbances in heart rhythm, physical activity and body temperature that are variously affected during insulin treatment.

  9. Bisphenol A Exposure and Cardiac Electrical Conduction in Excised Rat Hearts

    PubMed Central

    Jaimes, Rafael; Asfour, Huda; Swift, Luther M.; Wengrowski, Anastasia M.; Sarvazyan, Narine; Kay, Matthew W.

    2014-01-01

    Background: Bisphenol A (BPA) is used to produce polycarbonate plastics and epoxy resins that are widely used in everyday products, such as food and beverage containers, toys, and medical devices. Human biomonitoring studies have suggested that a large proportion of the population may be exposed to BPA. Recent epidemiological studies have reported correlations between increased urinary BPA concentrations and cardiovascular disease, yet the direct effects of BPA on the heart are unknown. Objectives: The goal of our study was to measure the effect of BPA (0.1–100 μM) on cardiac impulse propagation ex vivo using excised whole hearts from adult female rats. Methods: We measured atrial and ventricular activation times during sinus and paced rhythms using epicardial electrodes and optical mapping of transmembrane potential in excised rat hearts exposed to BPA via perfusate media. Atrioventricular activation intervals and epicardial conduction velocities were computed using recorded activation times. Results: Cardiac BPA exposure resulted in prolonged PR segment and decreased epicardial conduction velocity (0.1–100 μM BPA), prolonged action potential duration (1–100 μM BPA), and delayed atrioventricular conduction (10–100 μM BPA). These effects were observed after acute exposure (≤ 15 min), underscoring the potential detrimental effects of continuous BPA exposure. The highest BPA concentration used (100 μM) resulted in prolonged QRS intervals and dropped ventricular beats, and eventually resulted in complete heart block. Conclusions: Our results show that acute BPA exposure slowed electrical conduction in excised hearts from female rats. These findings emphasize the importance of examining BPA’s effect on heart electrophysiology and determining whether chronic in vivo exposure can cause or exacerbate conduction abnormalities in patients with preexisting heart conditions and in other high-risk populations. Citation: Posnack NG, Jaimes R III, Asfour H

  10. Acoustic heart. Interpretation of Phonocardiograms by computer

    NASA Astrophysics Data System (ADS)

    Granados, J.; Tavera, F.; Velázquez, J. M.; López, G.; Hernández, R. T.; Morales, A.

    2015-01-01

    In the field of Cardiology have been identified several heart pathologies associated with problems in valves and narrowing in veins. Each case is associated with a specific sound emitted by the heart, detected in cardiac auscultation. On the Phonocardiogram, sound is visualized as a peak in the wave. In the Optics Laboratory of the Universidad Autonoma Metropolitana - Azcapotzalco, we have developed a simulation of the Phonocardiograms of heart sounds associated with the main pathologies and a computer program of recognition of images that allows you to quickly identify the respective diseases. This is a novel way to analyze Phonocardiograms and the foundation for building a portable non-invasive cardiac diagnostic computerized analyzer system.

  11. Nutrition in the prevention of Coronary Heart Disease and the management of lipoprotein disorders

    USDA-ARS?s Scientific Manuscript database

    Cardiovascular disease (CVD) is comprised of coronary heart disease (CHD), stroke, and peripheral vascular disease (PVD). CVD is caused by progressive narrowing and blockage of arteries supplying the heart, brain, and other tissues and organs. CVD is the leading cause of death and disability in our ...

  12. A consensus algorithm for approximate string matching and its application to QRS complex detection

    NASA Astrophysics Data System (ADS)

    Alba, Alfonso; Mendez, Martin O.; Rubio-Rincon, Miguel E.; Arce-Santana, Edgar R.

    2016-08-01

    In this paper, a novel algorithm for approximate string matching (ASM) is proposed. The novelty resides in the fact that, unlike most other methods, the proposed algorithm is not based on the Hamming or Levenshtein distances, but instead computes a score for each symbol in the search text based on a consensus measure. Those symbols with sufficiently high scores will likely correspond to approximate instances of the pattern string. To demonstrate the usefulness of the proposed method, it has been applied to the detection of QRS complexes in electrocardiographic signals with competitive results when compared against the classic Pan-Tompkins (PT) algorithm. The proposed method outperformed PT in 72% of the test cases, with no extra computational cost.

  13. The arterial baroreflex effectiveness index in risk stratification of chronic heart failure patients who are candidates for cardiac resynchronization therapy.

    PubMed

    Fernandes Serôdio, João; Martins Oliveira, Mário; Matoso Laranjo, Sérgio; Tavares, Cristiano; Silva Cunha, Pedro; Abreu, Ana; Branco, Luísa; Alves, Sandra; Rocha, Isabel; Cruz Ferreira, Rui

    2016-06-01

    Baroreflex function is an independent marker of prognosis in heart failure (HF). However, little is known about its relation to response to cardiac resynchronization therapy (CRT). The aim of this study is to assess arterial baroreflex function in HF patients who are candidates for CRT. The study population consisted of 25 patients with indication for CRT, aged 65±10 years, NYHA functional class ≥III in 52%, QRS width 159±15 ms, left ventricular ejection fraction (LVEF) 29±5%, left ventricular end-systolic volume (LVESV) 150±48 ml, B-type natriuretic peptide (BNP) 357±270 pg/ml, and peak oxygen consumption (peak VO2) 18.4±5.0 ml/kg/min. An orthostatic tilt test was performed to assess the baroreflex effectiveness index (BEI) by the sequence method. This group was compared with 15 age-matched healthy individuals. HF patients showed a significantly depressed BEI during tilt (31±12% vs. 49±18%, p=0.001). A lower BEI was associated with higher BNP (p=0.038), lower peak VO2 (p=0.048), and higher LVESV (p=0.031). By applying a cut-off value of 25% for BEI, two clusters of patients were identified: lower risk cluster (BEI >25%) QRS 153 ms, LVESV 129 ml, BNP 146 pg/ml, peak VO2 19.0 ml/kg/min; and higher risk cluster (IEB ≤25%) QRS 167 ms, LVESV 189 ml, BNP 590 pg/ml, peak VO2 16.2 ml/kg/min. Candidates for CRT show depressed arterial baroreflex function. Lower BEI was observed in high-risk HF patients. Baroreflex function correlated closely with other clinical HF parameters. Therefore, BEI may improve risk stratification in HF patients undergoing CRT. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  14. Kubios HRV--heart rate variability analysis software.

    PubMed

    Tarvainen, Mika P; Niskanen, Juha-Pekka; Lipponen, Jukka A; Ranta-Aho, Perttu O; Karjalainen, Pasi A

    2014-01-01

    Kubios HRV is an advanced and easy to use software for heart rate variability (HRV) analysis. The software supports several input data formats for electrocardiogram (ECG) data and beat-to-beat RR interval data. It includes an adaptive QRS detection algorithm and tools for artifact correction, trend removal and analysis sample selection. The software computes all the commonly used time-domain and frequency-domain HRV parameters and several nonlinear parameters. There are several adjustable analysis settings through which the analysis methods can be optimized for different data. The ECG derived respiratory frequency is also computed, which is important for reliable interpretation of the analysis results. The analysis results can be saved as an ASCII text file (easy to import into MS Excel or SPSS), Matlab MAT-file, or as a PDF report. The software is easy to use through its compact graphical user interface. The software is available free of charge for Windows and Linux operating systems at http://kubios.uef.fi. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. Electrocardiographic parameters predict super-response in cardiac resynchronization therapy.

    PubMed

    Cvijić, Marta; Žižek, David; Antolič, Bor; Zupan, Igor

    2015-01-01

    Cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients. However, determinants of response to CRT remain elusive. The aim of the study was to assess the value of ECG parameters to predict super-response in CRT patients. A 12-lead surface ECG was recorded at baseline and immediately after CRT-device implantation. Baseline ECG parameters (QRS duration, bundle branch morphology, axis, PR interval, QTc, intrinsicoid deflection) and post-implant paced QRS duration were analyzed; relative change in QRS duration was calculated. Decrease of left ventricular end-systolic volume ≥30% after 12 months was classified as super-response. In group of 101 patients, 32 (31.7%) were super-responders. There were no significant differences in baseline ECG parameters between super-responders and other patients. Post-implant QRS duration was shorter in super-responders (148 ± 22 ms vs. 162 ± 28 ms; P=0.010). Only in super-responders was significant QRS reduction observed after implantation. Relative QRS shortening was higher in super-responders (12.1% (6.8 to 22.2) vs. 1.7% (-11.9 to 11.8); P=0.005). In a multivariable analysis post-implant QRS duration and relative QRS shortening remained independent predictor of super-response. Absolute post-implant QRS duration and relative QRS shortening are the only ECG parameters associated with super-response in CRT. Further prospective studies on larger population are warranted to determine our findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Is Perceptual Narrowing Too Narrow?

    ERIC Educational Resources Information Center

    Cashon, Cara H.; Denicola, Christopher A.

    2011-01-01

    There is a growing list of examples illustrating that infants are transitioning from having earlier abilities that appear more "universal," "broadly tuned," or "unconstrained" to having later abilities that appear more "specialized," "narrowly tuned," or "constrained." Perceptual narrowing, a well-known phenomenon related to face, speech, and…

  17. Electrocardiographic Impact of Myocardial Diffuse Fibrosis and Scar: MESA (Multi-Ethnic Study of Atherosclerosis)

    PubMed Central

    Inoue, Yuko Y.; Ambale-Venkatesh, Bharath; Mewton, Nathan; Volpe, Gustavo J.; Ohyama, Yoshiaki; Sharma, Ravi K.; Wu, Colin O.; Liu, Chia-Ying; Bluemke, David A.; Soliman, Elsayed Z.; Lima, João A. C.

    2017-01-01

    Purpose To examine the associations of myocardial diffuse fibrosis and scar with surface electrocardiographic (ECG) parameters in individuals free of prior coronary heart disease in four different ethnicities. Materials and Methods This prospective cross-sectional study was approved by the institutional review boards, and all participants gave informed consent. A total of 1669 participants in the Multi-Ethnic Study of Atherosclerosis, or MESA, who were free of prior myocardial infarction underwent both ECG and cardiac magnetic resonance imaging. In individuals without a late gadolinium enhancement–defined myocardial scar (n = 1131), T1 mapping was used to assess left ventricular (LV) interstitial diffuse fibrosis. The associations of LV diffuse fibrosis or myocardial scar with ECG parameters (QRS voltage, QRS duration, and corrected QT interval [QTc]) were evaluated by using multivariable regression analyses adjusted for demographic data, risk factors for scar, LV end-diastolic volume, and LV mass. Results The mean age of the 1669 participants was 67.4 years ± 8.7 (standard deviation); 49.8% were women. Lower postcontrast T1 time at 12 minutes was significantly associated with lower QRS Sokolow-Lyon voltage (β = 15.1 µV/10 msec, P = .004), lower QRS Cornell voltage (β = 9.2 µV/10 msec, P = .031), and shorter QRS duration (β = 0.16 msec/10 msec, P = .049). Greater extracellular volume (ECV) fraction was also significantly associated with lower QRS Sokolow-Lyon voltage (β = −35.2 µV/1% ECV increase, P < .001) and Cornell voltage (β = −23.7 µV/1% ECV increase, P < .001), independent of LV structural indexes. In contrast, the presence of LV scar (n = 106) was associated with longer QTc (β = 4.3 msec, P = .031). Conclusion In older adults without prior coronary heart disease, underlying greater LV diffuse fibrosis is associated with lower QRS voltage and shorter QRS duration at surface ECG, whereas clinically unrecognized myocardial scar is associated

  18. The role of electrocardiography in evaluation of severity of chronic obstructive pulmonary disease in daily clinical practice.

    PubMed

    Aktürk, Faruk; Bıyık, İsmail; Kocaş, Cüneyt; Ertürk, Mehmet; Yalçın, Ahmet Arif; Savaş, Ayfer Utku; Kuzer, Firuzan Pınar; Uzun, Fatih; Yıldırım, Aydın; Uslu, Nevzat; Çuhadaroğlu, Çağlar

    2013-01-01

    Chronic obstructive pulmonary disease (COPD) is the fourth leading cause of chronic morbidity and mortality. Bronchial obstruction and increased pulmonary vascular resistance impairs right atrial functions. In this study, we aimed to investigate the effect of bronchial obstruction on p wave axis in patients with COPD and usefulness of electrocardiography (ECG) in the evaluation of the severity of COPD. Ninety five patients (64 male and 31 female) included to the study. Patients were in sinus rhythm, with normal ejection fraction and heart chamber sizes. Their respiratory function tests and 12 lead electrocardiograms were obtained at same day. Correlations with severity of COPD and ECG findings including p wave axis, p wave duration, QRS axis, QRS duration were studied. The mean age was 58 ± 12 years. Their mean p wave axis was 62 ± 18 degrees. In this study, p wave axis has demonstrated significant positive correlations with stages of COPD and QRS axis but significant negative correlations with FEV1, FEF, BMI and QRS duration. P wave axis increases with increasing stages of COPD. Verticalization of the frontal p wave axis may be an early finding of worsening of COPD before occurrences of other ECG changes of hypertrophy and enlargement of right heart chambers such as p pulmonale. Verticalization of the frontal p wave axis reflecting right atrial electrical activity and right heart strain may be a useful parameter for quick estimation of the severity of COPD in an out-patient cared.

  19. Effects of amitriptyline and clomipramine in the isolated, perfused rabbit heart.

    PubMed

    Nielsen-Kudsk, F; Quist, S

    1980-04-01

    The cardiac effects of supratherapeutic concentrations of two tricyclic antidepressants were studied in isolated rabbit hearts, which were perfused with a modified Krebs-Henseleit solution containing 0.25 or 0.50 micrograms ml-1 of amitriptyline or 0.28 micrograms mg-1 of clomipramine. The following parameters were continuously recorded:heart rate, amplitude and rate of contraction, coronary flow rate, myocardial oxygen consumption and ECG. The lowest concentration of amitriptyline caused a time correlated decrease (20%) in the frequency of spontaneous beating and a pronounced decrease in the amplitude (62%) and rate of cardiac contraction (58%). Maximum increases of the PQ-interval of about 46% and of the QRS-complex of about 100% were observed. At the higher amitriptyline concentration these effect further increased. Clomipramine 0.28 micrograms ml-1 also had a very pronounced and time correlated negative inotropic effect, but the effects upon the conduction velocities were substantially lesser than those produced by the equimilar concentration of amitriptyline. The compounds caused only insignificant changes in coronary flow. The oxygen consumption did not decrease in proportion to the decrease in contractility, as an expression of decreased myocardial efficiency. The effects of the drugs are discussed in relation to theri myocardial accumulation pharmacokinetics and influence upon the membraneous sodium and calcium flux and intracellular metabolism.

  20. Time frequency power profile of QRS complex obtained with wavelet transform in spontaneously hypertensive rats.

    PubMed

    Takano, Nami K; Tsutsumi, Takeshi; Suzuki, Hiroshi; Okamoto, Yoshiwo; Nakajima, Toshiaki

    2012-02-01

    We evaluated whether frequency analysis could detect the development of interstitial fibrosis in rats. SHR/Izm and age-matched WKY/Izm were used. Limb lead II electrocardiograms were recorded. Continuous wavelet transform (CWT) was applied for the time-frequency analysis. The integrated time-frequency power (ITFP) between QRS complexes was measured and compared between groups. The ITFP at low-frequency bands (≤125Hz) was significantly higher in SHR/Izm. The percent change of ITFP showed the different patterns between groups. Prominent interstitial fibrosis with an increase in TIMP-1 mRNA expression was also observed in SHR/Izm. These results were partly reproduced in a computer simulation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Effects of atomoxetine on heart rhythm in children and adolescents.

    PubMed

    Tanidir, Ibrahim Cansaran; Tanidir, Canan; Ozturk, Erkut; Bahali, Kayhan; Gunes, Hatice; Ergul, Yakup; Uneri, Ozden Sukran; Akdeniz, Celal; Tuzcu, Volkan

    2015-12-01

    The aim of this study was to examine the effects of atomoxetine on heart rhythm using 12-lead electrocardiography (ECG) and 24 h Holter monitoring. Children and adolescents who were diagnosed with attention deficit-hyperactivity disorder according to DSM-IV-TR were referred to a pediatric cardiology clinic for cardiologic examination before and after 4 or 5 weeks of atomoxetine treatment. Cardiac examination, complete blood count, biochemistry, thyroid function tests, 12-lead ECG and 24 h Holter monitoring were performed routinely in all patients. Each subject underwent 24 h Holter ECG monitoring before atomoxetine was started and after 4 or 5 weeks of effective dose atomoxetine treatment. Forty-one patients were included in this prospective study. No statistically significant change was found in QT, QTc or QT interval dispersion or blood pressure before and after 4 or 5 weeks of atomoxetine treatment. There was a statistically significant increase in heart rate (both during the day and at night) and QRS duration, and a statistically significant decrease in P wave dispersion. Three patients had rhythm disturbances. All of these three patients were asymptomatic and none of these arrhythmias reached clinical significance. Atomoxetine did not cause significant changes in ECG or Holter variables. In two patients, who had undiagnosed subclinical extrasystoles, extra beats were increased after 4th week of treatment, but still remained clinically insignificant. Before and after atomoxetine treatment, listening to the heart sounds for a longer time, may help clinicians to notice an extra beat. If an extra beat is identified then 24 Holter monitoring is recommended. © 2015 Japan Pediatric Society.

  2. By the Numbers: Mortality Burden of Heart Disease and Cancer, 1950-2014.

    PubMed

    2016-10-01

    Although the number of deaths due to heart disease began a relatively steady decline in the 1990s, it remains the leading cause of death overall in the United States, followed by cancer. However, the gap between them has narrowed greatly since 1950, and in 2014, cancer deaths outnumbered deaths due to heart disease in 22 states. ©2016 American Association for Cancer Research.

  3. Ivabradine, a novel heart rate slower: is it a sword of double blades in patients with idiopathic dilated cardiomyopathy?

    PubMed

    Rayan, Mona; Tawfik, Mazen; Alabd, Ali; Gamal, Amr

    2011-08-01

    To prospectively assess the safety and efficacy of ivabradine in patients with idiopathic dilated cardiomyopathy. We included 35 patients with idiopathic dilated cardiomyopathy with an ejection fraction (EF) <40% and heart rate >70 beats/min despite optimal medical therapy, according to the international guidelines in this prospective, non-randomized, single-arm, open-label safety study. Ivabradine was used as an add-on therapy to the maximally tolerated b-blocker in an increasing titrated dose till a target dose of 15 mg/day or resting heart rate of 60 beats/min for 3 months. During follow-up period the safety, patient tolerance and efficacy of this drug were assessed. All patients underwent 12-lead resting electrocardiography and Holter monitoring at inclusion and after 3 months. Statistical analysis was accomplished using paired t-test and Pearson correlation analysis. We found a significant reduction in the resting heart rate by a mean of 25.9 ± 9.4%, without a significant change of blood pressure. There was no prolongation of PR, QTc or QRS durations. Ventricular ectopic activity showed significant reduction (p<0.001). There was a significant correlation between the resting heart rate, NYHA and left ventricular ejection fraction (p<0.001 for both). One patient developed photopsia and decompensation was observed in another patient. Ivabradine is a safe and effective drug in reducing resting heart rate, improving NYHA functional class without undesirable effects on conduction parameters or ectopic activity.

  4. A novel handheld device for use in remote patient monitoring of heart failure patients--design and preliminary validation on healthy subjects.

    PubMed

    Pollonini, Luca; Rajan, Nithin O; Xu, Shuai; Madala, Sridhar; Dacso, Clifford C

    2012-04-01

    Remote patient monitoring (RPM) holds great promise for reducing the burden of congestive heart failure (CHF). Improved sensor technology and effective predictive algorithms can anticipate sudden decompensation events. Enhanced telemonitoring systems would promote patient independence and facilitate communication between patients and their physicians. We report the development of a novel hand-held device, called Blue Box, capable of collecting and wirelessly transmitting key cardiac parameters derived from three integrated biosensors: 2 lead electrocardiogram (ECG), photoplethysmography and bioelectrical impedance (bioimpedance). Blue Box measurements include time intervals between consecutive ECG R-waves (RR interval), time duration of the ECG complex formed by the Q, R and S waves (QRS duration), bioimpedance, heart rate and systolic time intervals. In this study, we recruited 24 healthy subjects to collect several parameters measured by Blue Box and assess their value in correlating with cardiac output measured with Echo-Doppler. Linear correlation between the heart rate measured with Blue Box and cardiac output from Echo-Doppler had a group average correlation coefficient of 0.80. We found that systolic time intervals did not improve the model significantly. However, STIs did inversely correlate with increasing workloads.

  5. Late Gadolinium Enhancement Amount As an Independent Risk Factor for the Incidence of Adverse Cardiovascular Events in Patients with Stage C or D Heart Failure

    PubMed Central

    Liu, Tong; Ma, Xiaohai; Liu, Wei; Ling, Shukuan; Zhao, Lei; Xu, Lei; Song, Deli; Liu, Jie; Sun, Zhonghua; Fan, Zhanming; Luo, Taiyang; Kang, Junping; Liu, Xiaohui; Dong, Jianzeng

    2016-01-01

    Background: Myocardial fibrosis (MF) is a risk factor for poor prognosis in dilated cardiomyopathy (DCM). Late gadolinium enhancement (LGE) of the myocardium on cardiac magnetic resonance (CMR) represents MF. We examined whether the LGE amount increases the incidence of adverse cardiovascular events in patients with stage C or D heart failure (HF). Methods: Eighty-four consecutive patients with stage C or D HF, either ischemic or non-ischemic, were enrolled. Comprehensive clinical and CMR evaluations were performed. All patients were followed up for a composite endpoint of cardiovascular death, heart transplantation, and cardiac resynchronization therapy with defibrillator (CRT-D). Results: LGE was present in 79.7% of the end-stage HF patients. LGE distribution patterns were mid-wall, epi-myocardial, endo-myocardial, and the morphological patterns were patchy, transmural, and diffuse. During the average follow-up of 544 days, 13 (15.5%) patients had endpoint events: 7 patients cardiac death, 2 patients heart transplantation, and 4 patients underwent CRT-D implantation. On univariate analysis, LGE quantification on cardiac magnetic resonance, blood urine nitrogen, QRS duration on electrocardiogram, left ventricular end-diastolic diameter (LVEDD), and left ventricular end-diastolic volume (LVEDV) on CMR had the strongest associations with the composite endpoint events. However, on multivariate analysis for both Model I (after adjusting for age, sex, and body mass index) and Model II (after adjusting for age, sex, BMI, renal function, QRS duration, and atrial fibrillation on electrocardiogram, the etiology of HF, LVEF, CMR-LVEDD, and CMR-LVEDV), LGE amount was a significant risk factor for composite endpoint events (Model I 6SD HR 1.037, 95%CI 1.005–1.071, p = 0.022; Model II 6SD HR 1.045, 95%CI 1.001–1.084, p = 0.022). Conclusion: LGE amount from high-scale threshold on CMR increased the incidence of adverse cardiovascular events for patients in either stage C or

  6. Construction and Use of Resting 12-Lead High Fidelity ECG "SuperScores" in Screening for Heart Disease

    NASA Technical Reports Server (NTRS)

    Schlegel, T. T.; Arenare, B.; Greco, E. C.; DePalma, J. L.; Starc, V.; Nunez, T.; Medina, R.; Jugo, D.; Rahman, M.A.; Delgado, R.

    2007-01-01

    We investigated the accuracy of several conventional and advanced resting ECG parameters for identifying obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. Multiple conventional and advanced ECG parameters were studied for their individual and combined retrospective accuracies in detecting underlying disease, the advanced parameters falling within the following categories: 1) Signal averaged ECG, including 12-lead high frequency QRS (150-250 Hz) plus multiple filtered and unfiltered parameters from the derived Frank leads; 2) 12-lead P, QRS and T-wave morphology via singular value decomposition (SVD) plus signal averaging; 3) Multichannel (12-lead, derived Frank lead, SVD lead) beat-to-beat QT interval variability; 4) Spatial ventricular gradient (and gradient component) variability; and 5) Heart rate variability. Several multiparameter ECG SuperScores were derivable, using stepwise and then generalized additive logistic modeling, that each had 100% retrospective accuracy in detecting underlying CM or CAD. The performance of these same SuperScores was then prospectively evaluated using a test set of another 120 individuals (40 new individuals in each of the CM, CAD and control groups, respectively). All 12-lead ECG SuperScores retrospectively generated for CM continued to perform well in prospectively identifying CM (i.e., areas under the ROC curve greater than 0.95), with one such score (containing just 4 components) maintaining 100% prospective accuracy. SuperScores retrospectively generated for CAD performed somewhat less accurately, with prospective areas under the ROC curve typically in the 0.90-0.95 range. We conclude that resting 12-lead

  7. [Monitor of ECG signal and heart rate using a mobile phone with Bluetooth communication protocol].

    PubMed

    Becerra-Luna, Brayans; Dávila-García, Rodrigo; Salgado-Rodríguez, Paola; Martínez-Memije, Raúl; Infante-Vázquez, Oscar

    2012-01-01

    To develop a portable signal monitoring equipment for electrocardiography (ECG) and heart rate (HR), communicated with a mobile phone using the Bluetooth (BT) communication protocol for display of the signal on screen. A monitoring system was designed in which the electronic section performs the ECG signal acquisition, as well as amplification, filtering, analog to digital conversion and transmission of the ECG and HR using BT. Two programs were developed for the system. The first one calculates HR through QRS identification and sends the ECG signals and HR to the mobile, and the second program is an application to acquire and display them on the mobile screen. We developed a portable electronic system powered by a 9 volt battery, with amplification and bandwidth meeting the international standards for ECG monitoring. The QRS complex identification was performed using the second derivative algorithm, while the programs allow sending and receiving information from the ECG and HR via BT, and viewing it on the mobile screen. The monitoring is feasible within distances of 15 m and it has been tested in various mobiles telephones of brands Nokia®, Sony Ericsson® and Samsung®. This system shows an alternative for mobile monitoring using BT and Java 2 Micro Edition (J2ME) programming. It allows the register of the ECG trace and HR, and it can be implemented in different phones. Copyright © 2011 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  8. Variations of intrathoracic amount of blood as a reason of ECG voltage changes.

    PubMed

    Saltykova, Marina; Capderou, Andre; Atkov, Oleg; Gusakov, Victor; Konovalov, Gennagiy; Voronin, Leonid; Kaspranskiy, Rustem; Morgun, Valeriy; Bailliart, Olivier; Cermack, Milan; Vaïda, Pierre

    2003-10-01

    It is known that electroconduction of intrathoracic organs and tissues significantly influences the ECG voltage. It changes during therapy or exercise test due to redistribution and/or volume variations of blood and body fluids and their electroconductivity variations. This fact must be taken into consideration during interpretation of corresponding ECG. But there are no quantitative estimations of this influence on human ECG. The goals of this study were to estimate the influence of variations of thoracic electroconduction, and heart volume on QRS voltage in humans, due to gravity change. ECGs of 26 healthy volunteers were analyzed in upright and supine position. Experimental conditions-acute change of gravity--are created in a special aircraft flying on Kepler's parabola trajectory. Each parabola includes phases of normo-, hypergravity (blood shifts in caudal direction), and microgravity (blood redistributes in cranial direction). Amplitude of QRS in Frank leads in all phases has been analyzed. 2-D echo studies for six subjects were used for estimation of heart volume change. In an upright position during hypergravity the amplitude of R wave in Z increases in 95% of cases (mean 0.19 mV). During microgravity amplitude of R wave in Z decreases in 95% (mean 0.24 mV). In supine position changes of QRS voltage are not significantly. Blood redistribution during gravity change leads to changes of QRS voltage, which is more expressed and steady on R in Z lead: an average near 0.2 mV. It is due to the balance between two factors: (a). changes of degree of short circuiting by variations in the amount of blood in thorax (b). changes of distance between heart and electrodes as a result of change in the position, form, and volume of the heart.

  9. Noninvasive Diagnosis of Coronary Artery Disease Using 12-Lead High-Frequency Electrocardiograms

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Arenare, Brian

    2006-01-01

    A noninvasive, sensitive method of diagnosing certain pathological conditions of the human heart involves computational processing of digitized electrocardiographic (ECG) signals acquired from a patient at all 12 conventional ECG electrode positions. In the processing, attention is focused on low-amplitude, high-frequency components of those portions of the ECG signals known in the art as QRS complexes. The unique contribution of this method lies in the utilization of signal features and combinations of signal features from various combinations of electrode positions, not reported previously, that have been found to be helpful in diagnosing coronary artery disease and such related pathological conditions as myocardial ischemia, myocardial infarction, and congestive heart failure. The electronic hardware and software used to acquire the QRS complexes and perform some preliminary analyses of their high-frequency components were summarized in Real-Time, High-Frequency QRS Electrocardiograph (MSC- 23154), NASA Tech Briefs, Vol. 27, No. 7 (July 2003), pp. 26-28. To recapitulate, signals from standard electrocardiograph electrodes are preamplified, then digitized at a sampling rate of 1,000 Hz, then analyzed by the software that detects R waves and QRS complexes and analyzes them from several perspectives. The software includes provisions for averaging signals over multiple beats and for special-purpose nonrecursive digital filters with specific low- and high-frequency cutoffs. These filters, applied to the averaged signal, effect a band-pass operation in the frequency range from 150 to 250 Hz. The output of the bandpass filter is the desired high-frequency QRS signal. Further processing is then performed in real time to obtain the beat-to-beat root mean square (RMS) voltage amplitude of the filtered signal, certain variations of the RMS voltage, and such standard measures as the heart rate and R-R interval at any given time. A key signal feature analyzed in the present

  10. QRS classification and spatial combination for robust heart rate detection in low-quality fetal ECG recordings.

    PubMed

    Warmerdam, G; Vullings, R; Van Pul, C; Andriessen, P; Oei, S G; Wijn, P

    2013-01-01

    Non-invasive fetal electrocardiography (ECG) can be used for prolonged monitoring of the fetal heart rate (FHR). However, the signal-to-noise-ratio (SNR) of non-invasive ECG recordings is often insufficient for reliable detection of the FHR. To overcome this problem, source separation techniques can be used to enhance the fetal ECG. This study uses a physiology-based source separation (PBSS) technique that has already been demonstrated to outperform widely used blind source separation techniques. Despite the relatively good performance of PBSS in enhancing the fetal ECG, PBSS is still susceptible to artifacts. In this study an augmented PBSS technique is developed to reduce the influence of artifacts. The performance of the developed method is compared to PBSS on multi-channel non-invasive fetal ECG recordings. Based on this comparison, the developed method is shown to outperform PBSS for the enhancement of the fetal ECG.

  11. Diagnosis and ablation of multiform fascicular tachycardia.

    PubMed

    Sung, Raphael K; Kim, Albert M; Tseng, Zian H; Han, Frederick; Inada, Keiichi; Tedrow, Usha B; Viswanathan, Mohan N; Badhwar, Nitish; Varosy, Paul D; Tanel, Ronn; Olgin, Jeffrey E; Stephenson, William G; Scheinman, Melvin

    2013-03-01

    Fascicular tachycardia (FT) is an uncommon cause of monomorphic sustained ventricular tachycardia (VT). We describe 6 cases of FT with multiform QRS morphologies. Six of 823 consecutive VT cases were retrospectively analyzed and found attributable to FT with multiform QRS patterns, with 3 cases exhibiting narrow QRS VT as well. All underwent electrophysiology study including fascicular potential mapping, entrainment pacing, and electroanatomic mapping. The first 3 cases describe similar multiform VT patterns with successful ablation in the upper mid septum. Initially, a right bundle branch block (RBBB) VT with superior axis was induced. Radiofrequency catheter ablation (RFCA) targeting the left posterior fascicle (LPF) resulted in a second VT with RBBB inferior axis. RFCA in the upper septum just apical to the LBB potential abolished VT in all cases. Cases 4 and 5 showed RBBB VT with alternating fascicular block compatible with upper septal dependent VT, resulting in bundle branch reentrant VT (BBRT) after ablation of LPF and left anterior fascicle (LAF). Finally, Cases 5 and 6 demonstrated spontaneous shift in QRS morphology during VT, implicating participation of a third fascicle. In Case 6, successful ablation was achieved over the proximal LAF, likely representing insertion of the auxiliary fascicle near the proximal LAF. Multiform FTs show a reentrant mechanism using multiple fascicular branches. We hypothesize that retrograde conduction over the septal fascicle produces alternate fascicular patterns as well as narrow VT forms. Ablation of the respective fascicle was successful in abolishing FT but does not preclude development of BBRT unless septal fascicle is targeted and ablated. © 2012 Wiley Periodicals, Inc.

  12. Development and significance of a fetal electrocardiogram recorded by signal-averaged high-amplification electrocardiography.

    PubMed

    Hayashi, Risa; Nakai, Kenji; Fukushima, Akimune; Itoh, Manabu; Sugiyama, Toru

    2009-03-01

    Although ultrasonic diagnostic imaging and fetal heart monitors have undergone great technological improvements, the development and use of fetal electrocardiograms to evaluate fetal arrhythmias and autonomic nervous activity have not been fully established. We verified the clinical significance of the novel signal-averaged vector-projected high amplification ECG (SAVP-ECG) method in fetuses from 48 gravidas at 32-41 weeks of gestation and in 34 neonates. SAVP-ECGs from fetuses and newborns were recorded using a modified XYZ-leads system. Once noise and maternal QRS waves were removed, the P, QRS, and T wave intervals were measured from the signal-averaged fetal ECGs. We also compared fetal and neonatal heart rates (HRs), coefficients of variation of heart rate variability (CV) as a parasympathetic nervous activity, and the ratio of low to high frequency (LF/HF ratio) as a sympathetic nervous activity. The rate of detection of a fetal ECG by SAVP-ECG was 72.9%, and the fetal and neonatal QRS and QTc intervals were not significantly different. The neonatal CVs and LF/HF ratios were significantly increased compared with those in the fetus. In conclusion, we have developed a fetal ECG recording method using the SAVP-ECG system, which we used to evaluate autonomic nervous system development.

  13. Effect of Loss of Heart Rate Variability on T-Wave Heterogeneity and QT Variability in Heart Failure Patients: Implications in Ventricular Arrhythmogenesis.

    PubMed

    Nayyar, Sachin; Hasan, Muhammad A; Roberts-Thomson, Kurt C; Sullivan, Thomas; Baumert, Mathias

    2017-06-01

    Heart rate variability (HRV) modulates dynamics of ventricular repolarization. A diminishing value of HRV is associated with increased vulnerability to life-threatening ventricular arrhythmias, however the causal relationship is not well-defined. We evaluated if fixed-rate atrial pacing that abolishes the effect of physiological HRV, will alter ventricular repolarization wavefronts and is relevant to ventricular arrhythmogenesis. The study was performed in 16 subjects: 8 heart failure patients with spontaneous ventricular tachycardia [HFVT], and 8 subjects with structurally normal hearts (H Norm ). The T-wave heterogeneity descriptors [total cosine angle between QRS and T-wave loop vectors (TCRT, negative value corresponds to large difference in the 2 loops), T-wave morphology dispersion, T-wave loop dispersion] and QT intervals were analyzed in a beat-to-beat manner on 3-min records of 12-lead surface ECG at baseline and during atrial pacing at 80 and 100 bpm. The global T-wave heterogeneity was expressed as mean values of each of the T-wave morphology descriptors and variability in QT intervals (QTV) as standard deviation of QT intervals. Baseline T-wave morphology dispersion and QTV were higher in HFVT compared to H Norm subjects (p ≤ 0.02). While group differences in T-wave morphology dispersion and T-wave loop dispersion remained unaltered with atrial pacing, TCRT tended to fall more in HFVT patients compared to H Norm subjects (interaction p value = 0.086). Atrial pacing failed to reduce QTV in both groups, however group differences were augmented (p < 0.0001). Atrial pacing and consequent loss of HRV appears to introduce unfavorable changes in ventricular repolarization in HFVT subjects. It widens the spatial relationship between wavefronts of ventricular depolarization and repolarization. This may partly explain the concerning relation between poorer HRV and the risk of ventricular arrhythmias.

  14. Mechanical dyssynchrony is additive to ECG criteria and independently associated with reverse remodelling and clinical response to cardiac resynchronisation therapy in patients with advanced heart failure

    PubMed Central

    Bank, Alan J; Gage, Ryan M; Marek, Josef J; Onishi, Toshinari; Burns, Kevin V; Schwartzman, David; Saba, Samir; Gorcsan, John

    2015-01-01

    Background QRS duration and morphology are known established predictors of cardiac resynchronisation therapy (CRT) response, whereas mechanical dyssynchrony is not. Our aim was to determine if mechanical dyssynchrony provides independent prognostic information on CRT response. Methods We studied 369 consecutive patients with heart failure (HF) with low ejection fraction (EF) and widened QRS receiving CRT. Radial dyssynchrony (septal-posterior radial peak strain delay ≥130 ms by speckle tracking) assessment was possible in 318 patients (86%). Associations with left ventricular end-systolic volume (LVESV) changes were examined using linear regression, and clinical outcomes analysed using Cox regression adjusted for multiple established outcome correlates. Results Patients with radial dyssynchrony before CRT (64%) had greater improvements in EF (8.8±9.4 vs 6.1±9.7 units, p=0.04) and LVESV (−30±41 vs −10±30 mL, p<0.01). Radial dyssynchrony was independently associated with reduction in LVESV (regression coefficient −10.5 mL, 95% CI −20.5 to −0.5, p=0.040) as was left bundle-branch block (−17.7 mL, −27.6 to −7.7, p=0.001). Patients with radial dyssynchrony had a 46% lower incidence of death, transplant or implantation of a left ventricular assist device (adjusted HR 0.54, 95% CI 0.31 to 0.92, p=0.02) and a 39% lower incidence of death or HF hospitalisation (0.61, 0.40 to 0.93, p=0.02) over 2 years. Conclusions Radial dyssynchrony was associated with significant improvements in LVESV and clinical outcomes following CRT and is independent of QRS duration or morphology, and additive to current ECG selection criteria to predict response to CRT. PMID:25973213

  15. The Narrow-Line Region of Narrow-Line Seyfert 1 Galaxies

    NASA Astrophysics Data System (ADS)

    Rodríguez-Ardila, A.; Binette, Luc; Pastoriza, Miriani G.; Donzelli, Carlos J.

    2000-08-01

    This work studies the optical emission-line properties and physical conditions of the narrow-line region (NLR) of seven narrow-line Seyfert 1 galaxies (NLS1's) for which high signal-to-noise ratio spectroscopic observations were available. The resolution is 340 km s-1 (at Hα) over the wavelength interval 3700-9500 Å, enabling us to separate the broad and narrow components of the permitted emission lines. Our results show that the flux carried out by the narrow component of Hβ is, on average, 50% of the total line flux. As a result, the [O III] λ5007/Hβ ratio emitted in the NLR varies from 1 to 5, instead of the universally adopted value of 10. This has strong implications for the required spectral energy distribution that ionizes the NLR gas. Photoionization models that consider a NLR composed of a combination of matter-bounded and ionization-bounded clouds are successful at explaining the low [O III] λ5007/Hβ ratio and the weakness of low-ionization lines of NLS1's. Variation of the relative proportion of these two type of clouds nicely reproduces the dispersion of narrow-line ratios found among the NLS1 sample. Assuming similar physical model parameters of both NLS1's and the normal Seyfert 1 galaxy NGC 5548, we show that the observed differences of emission-line ratios between these two groups of galaxies can be explained, to a first approximation, in terms of the shape of the input ionizing continuum. Narrow emission-line ratios of NLS1's are better reproduced by a steep power-law continuum in the EUV-soft X-ray region, with spectral index α~-2. Flatter spectral indices (α~-1.5) match the observed line ratios of NGC 5548 but are unable to provide a good match to the NLS1 ratios. This result is consistent with ROSAT observations of NLS1's, which show that these objects are characterized by steeper power-law indices than those of Seyfert 1 galaxies with strong broad optical lines. Based on observations made at CASLEO. Complejo Astronómico El Leoncito

  16. Cardiac pacemaker battery discharge after external electrical cardioversion for broad QRS Complex Tachycardia.

    PubMed

    Annamaria, Martino; Andrea, Scapigliati; Michela, Casella; Tommaso, Sanna; Gemma, Pelargonio; Antonio, Dello Russo; Roberto, Zamparelli; Stefano, De Paulis; Fulvio, Bellocci; Rocco, Schiavello

    2008-08-01

    External electrical cardioversion or defibrillation may be necessary in patients with implanted cardiac pacemaker (PM) or implantable cardioverter defibrillator (ICD). Sudden discharge of high electrical energy employed in direct current (DC) transthoracic countershock may damage the PM/ICD system resulting in a series of possible device malfunctions. For this reason, when defibrillation or cardioversion must be attempted in a patient with a PM or ICD, some precautions should be taken, particularly in PM dependent patients, in order to prevent damage to the device. We report the case of a 76-year-old woman with a dual chamber PM implanted in the right subclavicular region, who received two consecutive transthoracic DC shocks to treat haemodynamically unstable broad QRS complex tachycardia after cardiac surgery performed with a standard sternotomic approach. Because of the sternal wound and thoracic drainage tubes together with the severe clinical compromise, the anterior paddle was positioned near the pulse generator. At the following PM test, a complete battery discharge was detected.

  17. Machine Learning Algorithm Predicts Cardiac Resynchronization Therapy Outcomes: Lessons From the COMPANION Trial.

    PubMed

    Kalscheur, Matthew M; Kipp, Ryan T; Tattersall, Matthew C; Mei, Chaoqun; Buhr, Kevin A; DeMets, David L; Field, Michael E; Eckhardt, Lee L; Page, C David

    2018-01-01

    Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in heart failure patients with reduced left ventricular function and intraventricular conduction delay. However, individual outcomes vary significantly. This study sought to use a machine learning algorithm to develop a model to predict outcomes after CRT. Models were developed with machine learning algorithms to predict all-cause mortality or heart failure hospitalization at 12 months post-CRT in the COMPANION trial (Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure). The best performing model was developed with the random forest algorithm. The ability of this model to predict all-cause mortality or heart failure hospitalization and all-cause mortality alone was compared with discrimination obtained using a combination of bundle branch block morphology and QRS duration. In the 595 patients with CRT-defibrillator in the COMPANION trial, 105 deaths occurred (median follow-up, 15.7 months). The survival difference across subgroups differentiated by bundle branch block morphology and QRS duration did not reach significance ( P =0.08). The random forest model produced quartiles of patients with an 8-fold difference in survival between those with the highest and lowest predicted probability for events (hazard ratio, 7.96; P <0.0001). The model also discriminated the risk of the composite end point of all-cause mortality or heart failure hospitalization better than subgroups based on bundle branch block morphology and QRS duration. In the COMPANION trial, a machine learning algorithm produced a model that predicted clinical outcomes after CRT. Applied before device implant, this model may better differentiate outcomes over current clinical discriminators and improve shared decision-making with patients. © 2018 American Heart Association, Inc.

  18. Bridging Computational Genetics and Vectorcardiography: A Robust Platform for the Early Detection of Heart Disease

    NASA Astrophysics Data System (ADS)

    Sridhar, S.

    2017-12-01

    By 2030, it is predicted that over 14 million people will die of heart disease annually, many of whom will discover their risk when it is too late to seek effective treatment or pursue lifestyle changes. In this research study, I sought to design a robust computational platform to gauge a patient's risk for cardiac diseases (CDs) based on demographics, genotype, and cardiac action potentials through machine learning, statistical analysis, and vectorcardiography. By analyzing previously published data, I discovered that certain polymorphisms in the ACE and MTHFR genes contribute significantly to CD risk. The deletion allele of the ACE insertion/deletion polymorphism increases ACE serum levels, promoting CD phenotypes. A point mutation in the MTHFR gene curbs the metabolism of folic acid, giving rise to CD phenotypes. I analyzed over 9000 British Medical Journal and American Heart Association patients to determine the CD risk associated with each ACE and MTHFR genotype. In the vectorcardiography phase of my study, I investigated trends in the maximal vectors of the QRS loop of the cardiac wave. Using a database with both normal and diseased vectorcardiographic action potentials, I plotted the maximal vectors on a 3D RAS coordinate plane to analyze their magnitude and direction. From the ACE datasets, I discovered that female patients over 45 and of Indian descent with two ACE deletion alleles exhibited the highest CD risk. Using this spectrum, I successfully constructed a neural network with an accuracy score of 0.867 that predicts CD risk based on ACE genotype, gender, region, and age. Investigation of the MTHFR genome showed that those with a homozygous mutated gene had a significantly higher CD risk. In my vectorcardiography study, I found that healthy QRS vectors pointed predominantly to the right-anterior region of the coordinate plane and exhibited short, consistent magnitudes. On the other hand, diseased vectors pointed to the left-posterior region and

  19. Right ventricular dyssynchrony in idiopathic pulmonary arterial hypertension: determinants and impact on pump function.

    PubMed

    Badagliacca, Roberto; Poscia, Roberto; Pezzuto, Beatrice; Papa, Silvia; Gambardella, Cristina; Francone, Marco; Mezzapesa, Mario; Nocioni, Martina; Nona, Alfred; Rosati, Riccardo; Sciomer, Susanna; Fedele, Francesco; Dario Vizza, Carmine

    2015-03-01

    Right ventricular (RV) dyssynchrony has been described in pulmonary arterial hypertension (PAH), but no evidence is available on its morphologic determinants and its effect on systolic function. The aim of this study was to evaluate the morphologic determinants of RV dyssynchrony by echocardiographic and cardiac magnetic resonance imaging and its effect on systolic function. In 60 consecutive idiopathic PAH (IPAH) patients with narrow QRS, RV dyssynchrony was evaluated by 2D speckle-tracking echocardiography, calculating the standard deviation of the times to peak systolic strain for the four mid-basal RV segments (RV-SD4). Patients were grouped by the median value of RV-SD4 (19 milliseconds) and compared for RV remodeling and systolic function parameters, WHO class, pulmonary hemodynamics and 6-minute walk test (6MWT). Despite similar pulmonary vascular resistance and mean pulmonary arterial pressure, patients with RV-SD4 at >19 milliseconds had advanced WHO class and worse 6MWT, RV hemodynamics, RV remodeling and systolic function parameters compared with patients at ≤19 milliseconds. The morphologic determinants of RV dyssynchrony resulted RV end-diastolic area, LV diastolic eccentricity index and RV mass volume ratio (r = 0.69, r(2) = 0.47, p < 0.0001). Finally, we found a significant inverse correlation between RV mid-basal segments post-systolic shortening time and cardiac index (r = -0.64, r(2) = 0.41, p = 0.001), accounting for the significant correlation between RV-SD4 and cardiac index (r = 0.57, r(2) = 0.32, p = 0.003). In IPAH with narrow QRS, RV dyssynchrony is associated with RV dilation and eccentric hypertrophy pattern, suggesting a role of segmental wall stress heterogeneity as the major determinant of mechanical delay. Post-systolic shortening, as inefficient contraction, contributes to pump dysfunction. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  20. Clinical significance of exercise pulmonary hypertension in secondary mitral regurgitation.

    PubMed

    Lancellotti, Patrizio; Magne, Julien; Dulgheru, Raluca; Ancion, Arnaud; Martinez, Christophe; Piérard, Luc A

    2015-05-15

    In patients with heart failure, exercise echocardiography can help in risk stratification and decision making. The prognostic significance of exercise pulmonary hypertension (PH) in patients with secondary mitral regurgitation (MR) remains unknown. The aim of the present study was to assess the prognostic value of exercise PH in patients with secondary MR and narrow QRS intervals. From 2005 to 2012, 159 consecutive patients with secondary MR, narrow QRS intervals, left ventricular dysfunction (mean ejection fraction 36 ± 7%), and measurable systolic pulmonary arterial pressure (SPAP) during exercise echocardiography were included. Resting and exercise PH were defined as SPAP >50 and >60 mm Hg, respectively. Exercise PH was more frequent than resting PH (40% vs 13%, p <0.0001). On multivariate logistic regression, the independent determinants of exercise PH were resting SPAP (p <0.0001), exercise MR severity (p <0.0001), and e'-wave velocity (p = 0.004). The incidence of cardiac events during follow-up was significantly higher in patients with exercise PH compared with those without exercise PH (4 years: 40 ± 7% vs 20 ± 5%, p <0.0001). Patients with exercise PH exhibited higher rates of cardiac events and death than those with resting PH. In a multivariate Cox proportional hazards model, exercise PH was independently associated with the occurrence of cardiac events (p <0.0001). In conclusion, in patients with secondary MR, exercise PH is determined mainly by resting SPAP, left ventricular diastolic burden, and exercise MR severity. Exercise PH is a powerful predictor of poor outcomes, with a 5.3-fold increased risk for cardiac-related death during follow-up. These results highlight the added value of exercise echocardiography in secondary MR. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Differentiating fasciculoventricular pathway from Wolff-Parkinson-White syndrome by electrocardiography.

    PubMed

    Suzuki, Tsugutoshi; Nakamura, Yoshihide; Yoshida, Shuichiro; Yoshida, Yoko; Shintaku, Haruo

    2014-04-01

    In school-based cardiovascular screening programs in Japan, Wolff-Parkinson-White (WPW) syndrome is diagnosed based on the presence of an electrocardiographic (ECG) delta wave without differentiation from the fasciculoventricular pathway (FVP), although the risk of sudden death is associated only with the former. The purpose of this study was to differentiate FVP patients among children diagnosed with WPW syndrome by ECG. Children who were diagnosed with WPW syndrome through school screening between April 2006 and March 2008 and had QRS width ≤120 ms were included. Patients with asthma and/or coronary heart disease were excluded. FVP and WPW syndrome were differentiated based on ECG responses to adenosine triphosphate (ATP) injection. Age, PR interval, QRS width, and Rosenbaum classification were compared among patients. Thirty patients (median age 12.7 years, range 6.5-15.7 years) participated in the study. FVP was diagnosed in 23 patients (76.7%), and WPW syndrome in 7 (23.3%). In Rosenbaum type A patients, all six patients had WPW syndrome, whereas FVP was diagnosed in 23 of 24 and WPW syndrome was diagnosed in 1 of 24 of type B patients. Age, PR interval, and QRS width were not significantly different between the two conditions. ATP stress test was reliable in differentiating FVP from WPW syndrome. Although FVP is considered rare, the results of our study indicate that many WPW syndrome patients with QRS width ≤120 ms may actually have FVP. Patients categorized as type B are more likely to have FVP, whereas type A patients are most likely to have WPW syndrome. © 2013 Heart Rhythm Society Published by Heart Rhythm Society All rights reserved.

  2. A new technique to determine the correlation between the QT interval and heart-rate for control and SIDS babies

    NASA Technical Reports Server (NTRS)

    Sadeh, D.; Shannon, D. C.; Abboud, S.; Akselrod, S.; Cohen, R. J.

    1987-01-01

    The ability of the autonomic nervous system to alter the QT interval in response to heart rate changes is essential to cardiovascular control. An accurate way to determine the relation between QT intervals and their corresponding RR intervals is described. A computer algorithm measures the RR intervals using digital filtering and cross-correlating the QRS sections of consecutive waveforms. The QT intervals is calculated by choosing a section of, the ECG that includes the T wave and cross-correlating it with all the consecutive T waves. At least 4000 pairs of QT-RR intervals are computed for each subject and a best fit correlation function determines the relations between the QT and RR intervals. This technique enables to establish a precise correlation between RR and QT in order to distinguish between control and SIDS babies.

  3. Narrow band gap amorphous silicon semiconductors

    DOEpatents

    Madan, A.; Mahan, A.H.

    1985-01-10

    Disclosed is a narrow band gap amorphous silicon semiconductor comprising an alloy of amorphous silicon and a band gap narrowing element selected from the group consisting of Sn, Ge, and Pb, with an electron donor dopant selected from the group consisting of P, As, Sb, Bi and N. The process for producing the narrow band gap amorphous silicon semiconductor comprises the steps of forming an alloy comprising amorphous silicon and at least one of the aforesaid band gap narrowing elements in amount sufficient to narrow the band gap of the silicon semiconductor alloy below that of amorphous silicon, and also utilizing sufficient amounts of the aforesaid electron donor dopant to maintain the amorphous silicon alloy as an n-type semiconductor.

  4. Assessment of atherosclerotic luminal narrowing of coronary arteries based on morphometrically generated visual guides.

    PubMed

    Barth, Rolf F; Kellough, David A; Allenby, Patricia; Blower, Luke E; Hammond, Scott H; Allenby, Greg M; Buja, L Maximilian

    Determination of the degree of stenosis of atherosclerotic coronary arteries is an important part of postmortem examination of the heart, but, unfortunately, estimation of the degree of luminal narrowing can be imprecise and tends to be approximations. Visual guides can be useful to assess this, but earlier attempts to develop such guides did not employ digital technology. Using this approach, we have developed two computer-generated morphometric guides to estimate the degree of luminal narrowing of atherosclerotic coronary arteries. The first is based on symmetric or eccentric circular or crescentic narrowing of the vessel lumen and the second on either slit-like or irregularly shaped narrowing of the vessel lumens. Using the Aperio ScanScope XT at a magnification of 20× we created digital whole-slide images of 20 representative microscopic cross sections of the left anterior descending (LAD) coronary artery, stained with either hematoxylin and eosin (H&E) or Movat's pentachrome stain. These cross sections illustrated a variety of luminal profiles and degrees of stenosis. Three representative types of images were selected and a visual guide was constructed with Adobe Photoshop CS5. Using the "Scale" and "Measurement" tools, we created a series of representations of stenosis with luminal cross sections depicting 20%, 40%, 60%, 70%, 80%, and 90% occlusion of the LAD branch. Four pathologists independently reviewed and scored the degree of atherosclerotic luminal narrowing based on our visual guides. In addition, digital technology was employed to determine the degree of narrowing by measuring the cross-sectional area of the 20 microscopic sections of the vessels, first assuming no narrowing and then comparing this to the percent of narrowing determined by precise measurement. Two of the observers were very experienced general autopsy pathologists, one was a first-year pathology resident on his first rotation on the autopsy service, and the fourth observer was a

  5. Itraconazole decreases left ventricular contractility in isolated rabbit heart: Mechanism of action

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qu, Yusheng, E-mail: yqu@amgen.com; Fang, Mei; Gao, BaoXi

    Itraconazole (ITZ) is an approved antifungal agent that carries a “black box warning” in its label regarding a risk of negative cardiac inotropy based on clinical findings. Since the mechanism of the negative inotropic effect is unknown, we performed a variety of preclinical and mechanistic studies to explore the pharmacological profile of ITZ and understand the negative inotropic mechanism. ITZ was evaluated in: (1) an isolated rabbit heart (IRH) preparation using Langendorff retrograde perfusion; (2) ion channel studies; (3) a rat heart mitochondrial function profiling screen; (4) a mitochondrial membrane potential (MMP) assay; (5) in vitro pharmacology profiling assays (148more » receptors, ion channels, transporters, and enzymes); and (6) a kinase selectivity panel (451 kinases). In the IRH, ITZ decreased cardiac contractility (> 30%) at 0.3 μM, with increasing effect at higher concentrations, which indicated a direct negative inotropic effect upon the heart. It also decreased heart rate and coronary flow (≥ 1 μM) and prolonged PR/QRS intervals (3 μM). In mechanistic studies, ITZ inhibited the cardiac NaV channel (IC{sub 50}: 4.2 μM) and was devoid of any functional inhibitory effect at the remaining pharmacological targets. Lastly, ITZ did not affect MMP, nor interfere with mitochondrial enzymes or processes involved with fuel substrate utilization or energy formation. Overall, the cardiovascular and mechanistic data suggest that ITZ-induced negative inotropy is a direct effect on the heart, in addition, the potential involvement of mitochondria function and L-type Ca{sup 2+} channels are eliminated. The exact mechanism underlying the negative inotropy is uncertain, and requires further study. - Highlights: ► Effect of itraconazole (ITZ) was assessed in the isolated rabbit heart (IRH) assay. ► ITZ decreased ventricular contractility in IRH, indicating a direct effect. ► IC{sub 50} of ITZ on L-type I{sub Ca} was greater than 30 μM, on I

  6. The effect of respiratory oscillations in heart rate on detrended fluctuation analysis

    NASA Astrophysics Data System (ADS)

    Govindan, Rathinaswamy B.; Kota, Srinivas; Al-Shargabi, Tareq; Swisher, Christopher B.; du Plessis, Adre

    2017-10-01

    Characterization of heart rate using detrended fluctuation analysis (DFA) is impeded by respiratory oscillations. In particular, the short-term exponent measured from 15 to 30 beats is compromised in the DFA. We reconstruct respiratory signal from electrocardiograms and attenuate the respiratory oscillation in the heart rate using a frequency-dependent subtraction approach. We validate this method by applying it to an electrocardiogram signal simulated using a coupled differential equation with the respiratory oscillation modelled using a sine function. The exponent estimated using the proposed approach agreed with the exponent incorporated in the model within a narrow range. In contrast, the exponent obtained from the raw data deviated from the expected value. Furthermore, the exponents obtained for the raw heart rate are smaller than the exponents obtained for the respiration oscillation attenuated heart rate. We apply this approach to heart rate measured from 12 preterm infants that were being treated for prematurity related complications. As observed in the simulated data, we show that compared to the raw heart rate, the respiratory oscillation attenuated heart rate shows higher short-term exponent (p < 0.001).

  7. Matched Filtering for Heart Rate Estimation on Compressive Sensing ECG Measurements.

    PubMed

    Da Poian, Giulia; Rozell, Christopher J; Bernardini, Riccardo; Rinaldo, Roberto; Clifford, Gari D

    2017-09-14

    Compressive Sensing (CS) has recently been applied as a low complexity compression framework for long-term monitoring of electrocardiogram signals using Wireless Body Sensor Networks. Long-term recording of ECG signals can be useful for diagnostic purposes and to monitor the evolution of several widespread diseases. In particular, beat to beat intervals provide important clinical information, and these can be derived from the ECG signal by computing the distance between QRS complexes (R-peaks). Numerous methods for R-peak detection are available for uncompressed ECG. However, in case of compressed sensed data, signal reconstruction can be performed with relatively complex optimisation algorithms, which may require significant energy consumption. This article addresses the problem of hearth rate estimation from compressive sensing electrocardiogram (ECG) recordings, avoiding the reconstruction of the entire signal. We consider a framework where the ECG signals are represented under the form of CS linear measurements. The QRS locations are estimated in the compressed domain by computing the correlation of the compressed ECG and a known QRS template. Experiments on actual ECG signals show that our novel solution is competitive with methods applied to the reconstructed signals. Avoiding the reconstruction procedure, the proposed method proves to be very convenient for real-time, low-power applications.

  8. Diagnostic electrocardiographic dyad criteria of emphysema in left ventricular hypertrophy

    PubMed Central

    Lanjewar, Swapnil S; Chhabra, Lovely; Chaubey, Vinod K; Joshi, Saurabh; Kulkarni, Ganesh; Kothagundla, Chandrasekhar; Kaul, Sudesh; Spodick, David H

    2013-01-01

    Background The electrocardiographic diagnostic dyad of emphysema, namely a combination of the frontal vertical P-vector and a narrow QRS duration, can serve as a quasidiagnostic marker for emphysema, with specificity close to 100%. We postulated that the presence of left ventricular hypertrophy in emphysema may affect the sensitivity of this electrocardiographic criterion given that left ventricular hypertrophy generates prominent left ventricular forces and may increase the QRS duration. Methods We reviewed the electrocardiograms and echocardiograms for 73 patients with emphysema. The patients were divided into two groups based on the presence or absence of echocardiographic evidence of left ventricular hypertrophy. The P-vector, QRS duration, and forced expiratory volume in one second (FEV1) were computed and compared between the two subgroups. Results There was no statistically significant difference in qualitative lung function (FEV1) between the subgroups. There was no statistically significant difference in mean P-vector between the subgroups. The mean QRS duration was significantly longer in patients with left ventricular hypertrophy as compared with those without left ventricular hypertrophy. Conclusion The presence of left ventricular hypertrophy may not affect the sensitivity of the P-vector verticalization when used as a lone criterion for diagnosing emphysema. However, the presence of left ventricular hypertrophy may significantly reduce the sensitivity of the electrocardiographic diagnostic dyad in emphysema, as it causes a widening of the QRS duration. PMID:24293995

  9. Diagnostic electrocardiographic dyad criteria of emphysema in left ventricular hypertrophy.

    PubMed

    Lanjewar, Swapnil S; Chhabra, Lovely; Chaubey, Vinod K; Joshi, Saurabh; Kulkarni, Ganesh; Kothagundla, Chandrasekhar; Kaul, Sudesh; Spodick, David H

    2013-01-01

    The electrocardiographic diagnostic dyad of emphysema, namely a combination of the frontal vertical P-vector and a narrow QRS duration, can serve as a quasidiagnostic marker for emphysema, with specificity close to 100%. We postulated that the presence of left ventricular hypertrophy in emphysema may affect the sensitivity of this electrocardiographic criterion given that left ventricular hypertrophy generates prominent left ventricular forces and may increase the QRS duration. We reviewed the electrocardiograms and echocardiograms for 73 patients with emphysema. The patients were divided into two groups based on the presence or absence of echocardiographic evidence of left ventricular hypertrophy. The P-vector, QRS duration, and forced expiratory volume in one second (FEV1) were computed and compared between the two subgroups. There was no statistically significant difference in qualitative lung function (FEV1) between the subgroups. There was no statistically significant difference in mean P-vector between the subgroups. The mean QRS duration was significantly longer in patients with left ventricular hypertrophy as compared with those without left ventricular hypertrophy. The presence of left ventricular hypertrophy may not affect the sensitivity of the P-vector verticalization when used as a lone criterion for diagnosing emphysema. However, the presence of left ventricular hypertrophy may significantly reduce the sensitivity of the electrocardiographic diagnostic dyad in emphysema, as it causes a widening of the QRS duration.

  10. Left ventricular dyssynchrony in patients with normal ventricular systolic function referred for exercise echocardiography.

    PubMed

    Bernheim, Alain M; Nakajima, Yoshie; Pellikka, Patricia A

    2008-10-01

    Exercise testing is often normal despite the presence of exertional symptoms. We hypothesized that left ventricular (LV) dyssynchrony might occur in some patients in the absence of ischemia, LV dysfunction, or wide QRS, and might contribute to exertional symptoms and diminished exercise capacity. Echocardiographic parameters were assessed before and with exercise in 40 patients (age 62 +/- 8 years, 27 with exertional symptoms). All had normal clinically indicated exercise echocardiograms and narrow QRS. The time to peak systolic velocity (Ts) was measured in 12 segments to calculate the standard deviation (Ts-SD) and the maximal difference (Ts-diff). At rest, 25 patients (63%) had dyssynchrony by Ts-SD. With exercise, mean Ts-SD did not increase significantly (34.9 +/- 19.3 ms vs 39.5 +/- 27.2 ms, P = .28). However, Ts-SD increased by greater than 40% in 15 patients (37.5%), remained stable in 19 patients (47.5%), and decreased by greater than 40% in 6 patients (15%). Similar responses were observed for Ts-diff. Patients with exercise-induced dyssynchrony were not more likely to have symptoms. Exercise capacity was inversely correlated with resting Ts-SD (r = -0.37, P = .02) and resting Ts-diff (r = -0.38, P = .02), but not with exercise-induced changes in dyssynchrony. Patients with resting dyssynchrony had higher resting heart rate (73 +/- 12 vs 63 +/- 11 beats/min, P = .02). LV dyssynchrony may occur more frequently than previously thought and may develop with exercise in the absence of ischemia. Exercise-induced LV dyssynchrony was not related to exertional symptoms or exercise capacity. Patients with dyssynchrony at rest had a higher resting heart rate and achieved a lower workload; this may indicate early myocardial impairment.

  11. Reproducibility of HTS-SQUID magnetocardiography in an unshielded clinical environment.

    PubMed

    Leder, U; Schrey, F; Haueisen, J; Dörrer, L; Schreiber, J; Liehr, M; Schwarz, G; Solbrig, O; Figulla, H R; Seidel, P

    2001-07-01

    A new technology has been developed which measures the magnetic field of the human heart (magnetocardiogram, MCG) by using high temperature superconducting (HTS) sensors. These sensors can be operated at the temperature of liquid nitrogen without electromagnetic shielding. We tested the reproducibility of HTS-MCG measurements in healthy volunteers. Unshielded HTS-MCG measurements were performed in 18 healthy volunteers in left precordial position in two separate sessions in a clinical environment. The heart cycles of 10 min were averaged, smoothed, the baselines were adjusted, and the data were standardized to the respective areas under the curves (AUC) of the absolute values of the QRST amplitudes. The QRS complexes and the ST-T intervals were used to assess the reproducibility of the two measurements. Ratios (R(QRS), R(STT)) were calculated by dividing the AUC of the first measurement by the ones of the second measurement. The linear correlation coefficients (CORR(QRS), CORR(STT)) of the time intervals of the two measurements were calculated, too. The HTS-MCG signal was completely concealed by the high noise level in the raw data. The averaging and smoothing algorithms unmasked the QRS complex and the ST segment. A high reproducibility was found for the QRS complex (R(QRS)=1.2+/-0.3, CORR(QRS)=0.96+/-0.06). Similarly to the shape of the ECG it was characterized by three bends, the Q, R, and S waves. In the ST-T interval, the reproducibility was considerably lower (R(STT)=0.9+/-0.2, CORR(STT)=0.66+/-0.28). In contrast to the shape of the ECG, a baseline deflection after the T wave which may belong to U wave activity was found in a number of volunteers. HTS-MCG devices can be operated in a clinical environment without shielding. Whereas the reproducibility was found to be high for the depolarization interval, it was considerably lower for the ST segment and for the T wave. Therefore, before clinically applying HTS-MCG systems to the detection of repolarization

  12. Detection of ischemical dyssynchrony in patients with normal duration of QRS at rest and during exercise echocardiography (Dyssynchrony in coronary artery disease patients during exercise).

    PubMed

    Zagatina, A; Guseva, O; Bartosh-Zelenaya, S Y; Zhuravskaya, N

    2014-04-01

    Ischemic segments cannot develop a sufficient amount of strength during systole, so theoretically they begin to contract later in comparison with non-ischemic zones. There is a lack of information about methods that can detect dyssynchrony during exercise in patients with QRS not longer 100 ms. The aim of the study was to compare different methods of detection regarding left ventricular moving dyssynchrony in patients with significant coronary stenosis artery lesions: pulsed-wave of PW-TDI, strain (S) and strain rate (SR). The study included 133 subjects: 106 consecutive patients who were scheduled for coronary angiography with previous stress-echocardiography and 27 healthy persons. All the patients underwent a supine bicycle exercise test. Seventy-six patients had stenoses and 30 subjects had no significant lesions by coronary angiography. There was a detectable difference between time parameters of left ventricle contraction for the two groups and controls before and during exercise using all Doppler methods. Subgroups of patients without previous myocardial infarction and without hypertrophy of left ventricle had the same results. Maximal difference was observed using strain method. There was a moderate correlation between time parameters and the existence of significant lesions of coronary arteries. Patients without prolongations of QRS with significant lesions of coronary arteries have detectable left ventricular dyssynchrony before and during exercise.

  13. Medicare Program Associated With Narrowing Hospital Readmission Disparities Between Black And White Patients.

    PubMed

    Figueroa, José F; Zheng, Jie; Orav, E John; Epstein, Arnold M; Jha, Ashish K

    2018-04-01

    The Hospital Readmissions Reduction Program has been associated with improvements in readmission rates, yet little is known about its effect on racial disparities. We compared trends in thirty-day readmission rates for congestive heart failure, acute myocardial infarction, and pneumonia among non-Hispanic whites versus non-Hispanic blacks, and among minority-serving hospitals versus others. During the penalty-free implementation period (April 2010-September 2012), readmission rates improved over pre-implementation trends (January 2007-March 2010) for both whites and blacks, with a significantly greater decline among blacks than among whites (-0.45 percent versus -0.36 percent per quarter, respectively). In the period October 2012-December 2014, after penalties began, readmission improvements slowed for both races. Following a similar pattern, minority-serving hospitals saw greater reductions in readmissions than other hospitals did. Despite the narrowing of the two race-based gaps after announcement of the Hospital Readmissions Reduction Program, both persist. It remains to be seen whether new policy efforts will narrow these gaps and reduce the disproportionately high penalties that minority-serving hospitals face.

  14. Value of the Electrocardiographic (P Wave, T Wave, QRS) Axis as a Predictor of Mortality in 14 Years in a Population With a High Prevalence of Chagas Disease from the Bambuí Cohort Study of Aging.

    PubMed

    Moraes, Diego N; Nascimento, Bruno R; Beaton, Andrea Z; Soliman, Elsayed Z; Lima-Costa, Maria Fernanda; Dos Reis, Rodrigo C P; Ribeiro, Antonio Luiz P

    2018-02-01

    We sought to investigate the prognostic value of the electrocardiogram (ECG) electrical axes (P wave, T wave and QRS) as predictors of mortality in the 14-year follow-up of the prospective cohort of all residents ≥60 years living in the southeastern Brazilian city of Bambuí, a population with high prevalence of Chagas disease (ChD). Baseline ECG axes were automatically measured with normal values defined as follows: P-wave axis 0° to 75°, QRS axis -30° to 90°, and T axis 15° to 75°. Participants underwent annual follow-up visits and death was verified using death certificates. Cox proportional hazards regression was used to assess the prognostic value of ECG axes for all-cause mortality, after adjustment for potential confounders. From 1,742 qualifying residents, 1,462 were enrolled, of whom 557 (38.1%) had ChD. Mortality rate was 51.9%. In multivariable adjusted models, abnormal P-wave axis was associated with a 48% (hazard ratio [HR] = 1.48 [95% confidence interval (CI) 1.16-1.88]) increased mortality risk in patients with ChD and 43% (HR = 1.43 [CI 1.13-1.81]) in patients without ChD. Abnormal QRS axis was associated with a 34% (HR = 1.34 [CI 1.04-1.73]) increased mortality risk in patients with ChD, but not in individuals without ChD. Similarly, in the ChD group, abnormal T-wave axis was associated with a 35% (HR = 1.35 [CI 1.07-1.71]) increased mortality, but not in patients without ChD. In conclusion, abnormal P-wave, QRS, and T-wave axes were associated with increased all-cause mortality in patients with ChD. Abnormal P-wave axis was associated with mortality also among those without ChD, being the strongest predictor among ECG variables. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Reconstitution of coronary vasculature by an active fraction of Geum japonicum in ischemic hearts

    NASA Astrophysics Data System (ADS)

    Chen, Hao; Cheng, Lei; Lin, Xiaoli; Zhou, Xiaping; Cai, Zhiming; Li, Ming

    2014-02-01

    Chronic coronary heart disease (cCHD) is characterized by atherosclerosis, which progressively narrows the coronary artery lumen and impairs myocardial blood flow. Restoration of occluded coronary vessels with newly formed collaterals remains an ideal therapeutic approach due to the need for redirecting blood flow into the ischemic heart. In this study, we investigated the effect of an active fraction isolated from Geum joponicum (AFGJ) on angiogenesis in cCHD hearts. Our results demonstrated that AFGJ not only enhanced capillary tube formation of endothelial cells, but also promoted the growth of new coronary collaterals (at the diameter 0.021-0.21 mm) in the ischemic region of hearts in rat cCHD model. Our study also indicated that the growth of new collaterals in ischemic hearts resulted in improved functional recovery of the cCHD hearts as demonstrated by ECG and echocardiography analyses. These data suggest that AFGJ may provide a novel therapeutic method for effective treatment of cCHD.

  16. Effect of Mobile Phone Radiofrequency Electromagnetic Fields on.

    PubMed

    Umar, Z U; Abubakar, M B; Ige, J; Igbokwe, U V; Mojiminiyi, F B O; Isezuo, S A

    2014-12-29

    Since cell phones emit radiofrequency electromagnetic fields (EMFs), this study tested the hypothesis that cell phones placed near the heart may interfere with the electrical rhythm of the heart or affect the blood pressure. Following informed consent, eighteen randomly selected apparently healthy male volunteers aged 21.44 ± 0.53 years had their blood pressure, pulse rates and ECG measured before and after acute exposure to a cell phone. The ECG parameters obtained were: heart rate (HR), QRS complex duration (QRS), PR interval (PR) and Corrected QT interval (QTc). Results are presented as mean ± SEM. Statistical analyses were done using two-tailed paired t test for blood pressure and pulse rate data and one way ANOVA with a post hoc Tukey test for the ECG data. P<0.05 was considered statistically significant. The blood pressure and pulse rates before and after exposure to the cell phone showed no significant difference. The ECG parameters (HR: beats/min, QRS:ms, PR:ms and QTc respectively) did not differ before (66.33 ± 2.50, 91.78 ± 1.36, 151.67 ± 5.39 and 395.44 ± 4.96), during (66.33 ± 2.40, 91.11 ± 1.61, 153.67 ± 5.06 and 394.33 ± 4.05) and after calls (67.22 ± 2.77, 91.11 ± 1.67, 157.44 ± 4.46 and 396.56 ± 4.93) compared to baseline (67.17 ± 2.19, 94.33 ± 1.57, 150.56 ± 4.93 and 399.56 ± 3.88). These results suggest that acute exposure to EMFs from cell phones placed near the heart may not interfere with the electrical activity of the heart or blood pressure in healthy individuals.

  17. Heart morphogenesis gene regulatory networks revealed by temporal expression analysis.

    PubMed

    Hill, Jonathon T; Demarest, Bradley; Gorsi, Bushra; Smith, Megan; Yost, H Joseph

    2017-10-01

    During embryogenesis the heart forms as a linear tube that then undergoes multiple simultaneous morphogenetic events to obtain its mature shape. To understand the gene regulatory networks (GRNs) driving this phase of heart development, during which many congenital heart disease malformations likely arise, we conducted an RNA-seq timecourse in zebrafish from 30 hpf to 72 hpf and identified 5861 genes with altered expression. We clustered the genes by temporal expression pattern, identified transcription factor binding motifs enriched in each cluster, and generated a model GRN for the major gene batteries in heart morphogenesis. This approach predicted hundreds of regulatory interactions and found batteries enriched in specific cell and tissue types, indicating that the approach can be used to narrow the search for novel genetic markers and regulatory interactions. Subsequent analyses confirmed the GRN using two mutants, Tbx5 and nkx2-5 , and identified sets of duplicated zebrafish genes that do not show temporal subfunctionalization. This dataset provides an essential resource for future studies on the genetic/epigenetic pathways implicated in congenital heart defects and the mechanisms of cardiac transcriptional regulation. © 2017. Published by The Company of Biologists Ltd.

  18. Atrial fibrillation driver mechanisms: Insight from the isolated human heart.

    PubMed

    Csepe, Thomas A; Hansen, Brian J; Fedorov, Vadim V

    2017-01-01

    Although there have been great technological advances in the treatment of atrial fibrillation (AF), current therapies remain limited due to a narrow understanding of AF mechanisms in the human heart. This review will highlight our recent studies on explanted human hearts where we developed and employed a novel functional-structural mapping approach by integrating high-resolution simultaneous endo-epicardial and panoramic optical mapping with 3D gadolinium-enhanced MRI to define the spatiotemporal characteristics of AF drivers and their structural substrates. The results allow us to postulate that the primary mechanism of AF maintenance in human hearts is a limited number of localized intramural microanatomic reentrant AF drivers anchored to heart-specific 3D fibrotically insulated myobundle tracks, which may remain hidden to clinical single-surface electrode mapping. We suggest that ex vivo human heart studies, by using an integrated 3D functional and structural mapping approach, will help to reveal defining features of AF drivers as well as validate and improve clinical approaches to detect and target these AF drivers in patients with cardiac diseases. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Significant impact of electrical storm on mortality in patients with structural heart disease and an implantable cardiac defibrillator.

    PubMed

    Noda, Takashi; Kurita, Takashi; Nitta, Takashi; Chiba, Yasutaka; Furushima, Hiroshi; Matsumoto, Naoki; Toyoshima, Takeshi; Shimizu, Akihiko; Mitamura, Hideo; Okumura, Ken; Ohe, Tohru; Aizawa, Yoshifusa

    2018-03-15

    Electrical storm (E-Storm), defined as multiple episodes of ventricular arrhythmias within a short period of time, is an important clinical problem in patients with an implantable cardiac defibrillator (ICD) including cardiac resynchronization therapy devices capable of defibrillation. The detailed clinical aspects of E-Storm in large populations especially for non-ischemic dilated cardiomyopathy (DCM), however, remain unclear. This study was performed to elucidate the detailed clinical aspects of E-Storm, such as its predictors and prevalence among patients with structural heart disease including DCM. We analyzed the data of the Nippon Storm Study, which was a prospective observational study involving 1570 patients enrolled from 48 ICD centers. For the purpose of this study, we evaluated 1274 patients with structural heart disease, including 482 (38%) patients with ischemic heart disease (IHD) and 342 (27%) patients with DCM. During a median follow-up of 28months (interquartile range: 23 to 33months), E-Storm occurred in 84 (6.6%) patients. The incidence of E-Storm was not significantly different between patients with IHD and patients with DCM (log-rank p=0.52). Proportional hazard regression analyses showed that ICD implantation for secondary prevention of sudden cardiac death (p=0.0001) and QRS width (p=0.015) were the independent risk factors for E-storm. In a comparison between patients with and without E-Storm, survival curves after adjustment for clinical characteristics showed a significant difference in mortality. E-Storm was associated with subsequent mortality in patients with structural heart disease including DCM. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Transvenous versus open chest lead placement for resynchronization therapy in patients with heart failure: comparison of ventricular electromechanical synchronicity.

    PubMed

    Zhang, Hai-Bo; Meng, Xu; Han, Jie; Li, Yan; Zhang, Ye; Jiang, Teng-Yong; Zhao, Ying-Xin; Zhou, Yu-Jie

    2017-04-01

    Transvenous lead placement is the standard approach for left ventricular (LV) pacing in cardiac resynchronization therapy (CRT), while the open chest access epicardial lead placement is currently the most frequently used second choice. Our study aimed to compare the ventricular electromechanical synchronicity in patients with heart failure after CRT with these two different LV pacing techniques. We enrolled 33 consecutive patients with refractory heart failure secondly to dilated cardiomyopathy who were eligible for CRT in this study. Nineteen patients received transvenous (TV group) while 14 received open chest (OP group) LV lead pacing. Intra- and inter-ventricular electromechanical synchronicity was assessed by tissue Doppler imaging (TDI) before and one year after CRT procedure. Before CRT procedure, the mean QRS-duration, maximum time difference to systolic peak velocity among 12 left ventricle segments (LV Ts-12), standard deviation of time difference to systolic peak velocity of 12 left ventricle segments (LV Ts-SD), and inter-ventricular mechanical delay (IVMD) in OP and TV group were 166 ± 17 ms and 170 ± 21 ms, 391 ± 42 ms and 397 ± 36 ms, 144 ± 30 ms and 148 ± 22 ms, 58 ± 25 ms and 60 ± 36 ms, respectively (all P > 0.05). At one year after the CRT, the mean QRS-duration, LV Ts-12, LV Ts-SD, and IVMD in TV and OP group were 128 ± 14 ms and 141 ± 22 ms ( P = 0.031), 136 ± 37 ms and 294 ± 119 ms ( P = 0.023), 50 ± 22 ms and 96 ± 34 ms ( P = 0.015), 27 ± 11 ms and 27 ± 26 ms ( P = 0.86), respectively. The LV lead implantation procedure time was 53.4 ± 16.3 min for OP group and 136 ± 35.1 min for TV group ( P = 0.016). The mean LV pacing threshold increased significantly from 1.7 ± 0.6 V/0.5 ms to 2.3 ± 1.6 V/0.5 ms ( P < 0.05) in TV group while it remained stable in the OP group. Compared to conventional endovascular approach, open chest access of LV pacing for CRT leads to better improvement of the intraventricular synchronization.

  1. Association of low-moderate urine arsenic and QT interval: Cross-sectional and longitudinal evidence from the Strong Heart Study.

    PubMed

    Moon, Katherine A; Zhang, Yiyi; Guallar, Eliseo; Francesconi, Kevin A; Goessler, Walter; Umans, Jason G; Best, Lyle G; Howard, Barbara V; Devereux, Richard B; Okin, Peter M; Navas-Acien, Ana

    2018-05-21

    Epidemiologic studies suggest that chronic exposure to arsenic is related to cardiovascular disease (CVD), but the pathophysiological link remains uncertain. We evaluated the association of chronic low-moderate arsenic exposure and arsenic metabolism with baseline difference and annual change in ECG measures (QT interval, JT interval, PR interval, QRS duration, and QT dispersion) using linear mixed models in the Strong Heart Study main cohort (N = 1174, median age 55 years) and family study (N = 1695 diabetes-free, median age 36 years). At baseline, arsenic exposure was measured as the sum of inorganic and methylated species in urine (ΣAs) and arsenic metabolism was measured as the relative percentage of arsenic species. Median ΣAs and Bazett heart rate-corrected QT interval (QTc) were 8.6 μg/g creatinine and 424 ms in the main cohort and 4.3 μg/g and 414 ms in the family study, respectively. In the main cohort, a comparison of the highest to lowest ΣAs quartile (>14.4 vs. <5.2 μg/g creatinine) was associated with a 5.3 (95% CI: 1.2, 9.5) ms higher mean baseline QTc interval but no difference in annual change in QTc interval. In the family study, a comparison of the highest to lowest quartile (>7.1 vs. <2.9 μg/g creatinine) was associated with a 3.2 (95% CI: 0.6, 5.7) ms higher baseline QTc interval and a 0.6 (95% CI: 0.04, 1.2) ms larger annual increase in QTc interval. Associations with JTc interval were similar but stronger in magnitude compared to QTc interval. Arsenic exposure was largely not associated with PR interval, QRS duration or QT dispersion. Similar to arsenic exposure, a pattern of lower %MMA and higher %DMA was associated with longer baseline QTc interval in both cohorts and with a larger annual change in QTc interval in the family study. Chronic low-moderate arsenic exposure and arsenic metabolism were associated with prolonged ventricular repolarization. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. The heart tube forms and elongates through dynamic cell rearrangement coordinated with foregut extension.

    PubMed

    Kidokoro, Hinako; Yonei-Tamura, Sayuri; Tamura, Koji; Schoenwolf, Gary C; Saijoh, Yukio

    2018-03-29

    In the initiation of cardiogenesis, the heart primordia transform from bilateral flat sheets of mesoderm into an elongated midline tube. Here, we discover that this rapid architectural change is driven by actomyosin-based oriented cell rearrangement and resulting dynamic tissue reshaping (convergent extension, CE). By labeling clusters of cells spanning the entire heart primordia, we show that the heart primordia converge toward the midline to form a narrow tube, while extending perpendicularly to rapidly lengthen it. Our data for the first time visualize the process of early heart tube formation from both the medial (second) and lateral (first) heart fields, revealing that both fields form the early heart tube by essentially the same mechanism. Additionally, the adjacent endoderm coordinately forms the foregut through previously unrecognized movements that parallel those of the heart mesoderm and elongates by CE. In conclusion, our data illustrate how initially two-dimensional flat primordia rapidly change their shapes and construct the three-dimensional morphology of emerging organs in coordination with neighboring morphogenesis. © 2018. Published by The Company of Biologists Ltd.

  3. A systematic approach to designing reliable VV optimization methodology: assessment of internal validity of echocardiographic, electrocardiographic and haemodynamic optimization of cardiac resynchronization therapy.

    PubMed

    Kyriacou, Andreas; Li Kam Wa, Matthew E; Pabari, Punam A; Unsworth, Beth; Baruah, Resham; Willson, Keith; Peters, Nicholas S; Kanagaratnam, Prapa; Hughes, Alun D; Mayet, Jamil; Whinnett, Zachary I; Francis, Darrel P

    2013-08-10

    In atrial fibrillation (AF), VV optimization of biventricular pacemakers can be examined in isolation. We used this approach to evaluate internal validity of three VV optimization methods by three criteria. Twenty patients (16 men, age 75 ± 7) in AF were optimized, at two paced heart rates, by LVOT VTI (flow), non-invasive arterial pressure, and ECG (minimizing QRS duration). Each optimization method was evaluated for: singularity (unique peak of function), reproducibility of optimum, and biological plausibility of the distribution of optima. The reproducibility (standard deviation of the difference, SDD) of the optimal VV delay was 10 ms for pressure, versus 8 ms (p=ns) for QRS and 34 ms (p<0.01) for flow. Singularity of optimum was 85% for pressure, 63% for ECG and 45% for flow (Chi(2)=10.9, p<0.005). The distribution of pressure optima was biologically plausible, with 80% LV pre-excited (p=0.007). The distributions of ECG (55% LV pre-excitation) and flow (45% LV pre-excitation) optima were no different to random (p=ns). The pressure-derived optimal VV delay is unaffected by the paced rate: SDD between slow and fast heart rate is 9 ms, no different from the reproducibility SDD at both heart rates. Using non-invasive arterial pressure, VV delay optimization by parabolic fitting is achievable with good precision, satisfying all 3 criteria of internal validity. VV optimum is unaffected by heart rate. Neither QRS minimization nor LVOT VTI satisfy all validity criteria, and therefore seem weaker candidate modalities for VV optimization. AF, unlinking interventricular from atrioventricular delay, uniquely exposes resynchronization concepts to experimental scrutiny. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. The spatial QRS-T angle in the Frank vectorcardiogram: accuracy of estimates derived from the 12-lead electrocardiogram.

    PubMed

    Schreurs, Charlotte A; Algra, Annemijn M; Man, Sum-Che; Cannegieter, Suzanne C; van der Wall, Ernst E; Schalij, Martin J; Kors, Jan A; Swenne, Cees A

    2010-01-01

    The spatial QRS-T angle (SA), a predictor of sudden cardiac death, is a vectorcardiographic variable. Gold standard vertorcardiograms (VCGs) are recorded by using the Frank electrode positions. However, with the commonly available 12-lead ECG, VCGs must be synthesized by matrix multiplication (inverse Dower matrix/Kors matrix). Alternatively, Rautaharju proposed a method to calculate SA directly from the 12-lead ECG. Neither spatial angles computed by using the inverse Dower matrix (SA-D) nor by using the Kors matrix (SA-K) or by using Rautaharju's method (SA-R) have been validated with regard to the spatial angles as directly measured in the Frank VCG (SA-F). Our present study aimed to perform this essential validation. We analyzed SAs in 1220 simultaneously recorded 12-lead ECGs and VCGs, in all data, in SA-F-based tertiles, and after stratification according to pathology or sex. Linear regression of SA-K, SA-D, and SA-R on SA-F yielded offsets of 0.01 degree, 20.3 degrees, and 28.3 degrees and slopes of 0.96, 0.86, and 0.79, respectively. The bias of SA-K with respect to SA-F (mean +/- SD, -3.2 degrees +/- 13.9 degrees) was significantly (P < .001) smaller than the bias of both SA-D and SA-R with respect to SA-F (8.0 degrees +/- 18.6 degrees and 9.8 degrees +/- 24.6 degrees, respectively); tertile analysis showed a much more homogeneous behavior of the bias in SA-K than of both the bias in SA-D and in SA-R. In pathologic ECGs, there was no significant bias in SA-K; bias in men and women did not differ. SA-K resembled SA-F best. In general, when there is no specific reason either to synthesize VCGs with the inverse Dower matrix or to calculate the spatial QRS-T angle with Rautaharju's method, it seems prudent to use the Kors matrix. Copyright 2010 Elsevier Inc. All rights reserved.

  5. 52 Genetic Loci Influencing Myocardial Mass

    PubMed Central

    van der Harst, Pim; van Setten, Jessica; Verweij, Niek; Vogler, Georg; Franke, Lude; Maurano, Matthew T.; Wang, Xinchen; Leach, Irene Mateo; Eijgelsheim, Mark; Sotoodehnia, Nona; Hayward, Caroline; Sorice, Rossella; Meirelles, Osorio; Lyytikäinen, Leo-Pekka; Polašek, Ozren; Tanaka, Toshiko; Arking, Dan E.; Ulivi, Sheila; Trompet, Stella; Müller-Nurasyid, Martina; Smith, Albert V.; Dörr, Marcus; Kerr, Kathleen F.; Magnani, Jared W.; Fabiola Del Greco, M.; Zhang, Weihua; Nolte, Ilja M.; Silva, Claudia T.; Padmanabhan, Sandosh; Tragante, Vinicius; Esko, Tõnu; Abecasis, Gonçalo R.; Adriaens, Michiel E.; Andersen, Karl; Barnett, Phil; Bis, Joshua C.; Bodmer, Rolf; Buckley, Brendan M.; Campbell, Harry; Cannon, Megan V.; Chakravarti, Aravinda; Chen, Lin Y.; Delitala, Alessandro; Devereux, Richard B.; Doevendans, Pieter A.; Dominiczak, Anna F.; Ferrucci, Luigi; Ford, Ian; Gieger, Christian; Harris, Tamara B.; Haugen, Eric; Heinig, Matthias; Hernandez, Dena G.; Hillege, Hans L.; Hirschhorn, Joel N.; Hofman, Albert; Hubner, Norbert; Hwang, Shih-Jen; Iorio, Annamaria; Kähönen, Mika; Kellis, Manolis; Kolcic, Ivana; Kooner, Ishminder K.; Kooner, Jaspal S.; Kors, Jan A.; Lakatta, Edward G.; Lage, Kasper; Launer, Lenore J.; Levy, Daniel; Lundby, Alicia; Macfarlane, Peter W.; May, Dalit; Meitinger, Thomas; Metspalu, Andres; Nappo, Stefania; Naitza, Silvia; Neph, Shane; Nord, Alex S.; Nutile, Teresa; Okin, Peter M.; Olsen, Jesper V.; Oostra, Ben A.; Penninger, Josef M.; Pennacchio, Len A.; Pers, Tune H.; Perz, Siegfried; Peters, Annette; Pinto, Yigal M.; Pfeufer, Arne; Pilia, Maria Grazia; Pramstaller, Peter P.; Prins, Bram P.; Raitakari, Olli T.; Raychaudhuri, Soumya; Rice, Ken M.; Rossin, Elizabeth J.; Rotter, Jerome I.; Schafer, Sebastian; Schlessinger, David; Schmidt, Carsten O.; Sehmi, Jobanpreet; Silljé, Herman H.W.; Sinagra, Gianfranco; Sinner, Moritz F.; Slowikowski, Kamil; Soliman, Elsayed Z.; Spector, Timothy D.; Spiering, Wilko; Stamatoyannopoulos, John A.; Stolk, Ronald P.; Strauch, Konstantin; Tan, Sian-Tsung; Tarasov, Kirill V.; Trinh, Bosco; Uitterlinden, Andre G.; van den Boogaard, Malou; van Duijn, Cornelia M.; van Gilst, Wiek H.; Viikari, Jorma S.; Visscher, Peter M.; Vitart, Veronique; Völker, Uwe; Waldenberger, Melanie; Weichenberger, Christian X.; Westra, Harm-Jan; Wijmenga, Cisca; Wolffenbuttel, Bruce H.; Yang, Jian; Bezzina, Connie R.; Munroe, Patricia B.; Snieder, Harold; Wright, Alan F.; Rudan, Igor; Boyer, Laurie A.; Asselbergs, Folkert W.; van Veldhuisen, Dirk J.; Stricker, Bruno H.; Psaty, Bruce M.; Ciullo, Marina; Sanna, Serena; Lehtimäki, Terho; Wilson, James F.; Bandinelli, Stefania; Alonso, Alvaro; Gasparini, Paolo; Jukema, J. Wouter; Kääb, Stefan; Gudnason, Vilmundur; Felix, Stephan B.; Heckbert, Susan R.; de Boer, Rudolf A.; Newton-Cheh, Christopher; Hicks, Andrew A.; Chambers, John C.; Jamshidi, Yalda; Visel, Axel; Christoffels, Vincent M.; Isaacs, Aaron; Samani, Nilesh J.; de Bakker, Paul I.W.

    2017-01-01

    BACKGROUND Myocardial mass is a key determinant of cardiac muscle function and hypertrophy. Myocardial depolarization leading to cardiac muscle contraction is reflected by the amplitude and duration of the QRS complex on the electrocardiogram (ECG). Abnormal QRS amplitude or duration reflect changes in myocardial mass and conduction, and are associated with increased risk of heart failure and death. OBJECTIVES This meta-analysis sought to gain insights into the genetic determinants of myocardial mass. METHODS We carried out a genome-wide association meta-analysis of 4 QRS traits in up to 73,518 individuals of European ancestry, followed by extensive biological and functional assessment. RESULTS We identified 52 genomic loci, of which 32 are novel, that are reliably associated with 1 or more QRS phenotypes at p < 1 × 10−8. These loci are enriched in regions of open chromatin, histone modifications, and transcription factor binding, suggesting that they represent regions of the genome that are actively transcribed in the human heart. Pathway analyses provided evidence that these loci play a role in cardiac hypertrophy. We further highlighted 67 candidate genes at the identified loci that are preferentially expressed in cardiac tissue and associated with cardiac abnormalities in Drosophila melanogaster and Mus musculus. We validated the regulatory function of a novel variant in the SCN5A/SCN10A locus in vitro and in vivo. CONCLUSIONS Taken together, our findings provide new insights into genes and biological pathways controlling myocardial mass and may help identify novel therapeutic targets. PMID:27659466

  6. Heart disease versus cancer: understanding perceptions of population prevalence and personal risk.

    PubMed

    Scheideler, Jennifer K; Taber, Jennifer M; Ferrer, Rebecca A; Grenen, Emily G; Klein, William M P

    2017-10-01

    Although the gap is narrowing, Americans are more likely to be diagnosed with and die from heart disease than cancer, and yet many believe cancer is more common and their personal risk of cancer is higher than their heart disease risk. Using nationally representative 2013 Health Information National Trends Survey data, we assessed such beliefs and examined sociodemographic and psychological factors and health behaviors associated with these beliefs. 42.8% of participants rated cancer as more common and 78.5% rated their own cancer risk as equal to or exceeding their heart disease risk. These misperceptions were only modestly correlated. Beliefs about relative population risk were associated with various psychological factors, whereas beliefs about relative personal risk were not. Both beliefs were inconsistently associated with health behaviors. Accuracy in beliefs about cancer and heart disease relative risk and prevalence is low and future research should explore antecedents and consequences of these beliefs.

  7. Effects of ice massage of the head and spine on heart rate variability in healthy volunteers.

    PubMed

    Mooventhan, A; Nivethitha, L

    2016-07-01

    Ice massage (IM) is one of the treatment procedures used in hydrotherapy. Though its various physiological/therapeutic effects have been reported, effects of IM of the head and spine on heart rate variability (HRV) have not been studied. Thus, this study evaluated the effects of IM of the head and spine on HRV in healthy volunteers. Thirty subjects were randomly divided into 3 sessions: (1) IM, (2) tap water massage (TWM) and (3) prone rest (PR). Heart rate (HR) and HRV were assessed before and after each intervention session. A significant increase in the mean of the intervals between adjacent QRS complexes or the instantaneous HR (RRI), square root of mean of sum of squares of differences between adjacent normal to normal (NN) intervals (RMSSD), number of interval differences of successive NN intervals greater than 50 milliseconds (NN50), proportion derived by dividing NN50 by total number of NN intervals along with significant reduction in HR after IM session; significant increase in RRI along with significant reduction in HR after TWM, and a significant increase only in RMSSD after PR were observed. However, there was no significant difference between the sessions. Results of this study suggest that 20 min of IM of the head and spine is effective in reducing HR and improving HRV through vagal dominance in healthy volunteers.

  8. Narrow-headed garter snake (Thamnophis rufipunctatus)

    USGS Publications Warehouse

    Nowak, Erika M.

    2006-01-01

    The narrow-headed garter snake is a harmless, nonvenomous snake that is distinguished by its elongated, triangular-shaped head and the red or dark spots on its olive to tan body. Today, the narrow-headed garter snake is a species of special concern in the United States because of its decline over much of its historic range. Arizona's Oak Creek has historically contained the largest population of narrow-headed garter snakes in the United States. The U.S. Geological Survey (USGS) and the Arizona Game and Fish Department jointly funded research by USGS scientists in Oak Creek to shed light on the factors causing declining population numbers. The research resulted in better understanding of the snake's habitat needs, winter and summer range, and dietary habits. Based on the research findings, the U.S. Forest Service has developed recommendations that visitors and local residents can adopt to help slow the decline of the narrow-headed garter snake in Oak Creek.

  9. A three-lead, programmable, and microcontroller-based electrocardiogram generator with frequency domain characteristics of heart rate variability.

    PubMed

    Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing

    2012-04-01

    The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment. © 2012 American Institute of Physics

  10. A three-lead, programmable, and microcontroller-based electrocardiogram generator with frequency domain characteristics of heart rate variability

    NASA Astrophysics Data System (ADS)

    Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing

    2012-04-01

    The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment.

  11. Frozen Plains in the Heart of Pluto Heart

    NASA Image and Video Library

    2015-07-17

    At center left of Pluto vast heart-shaped feature "Tombaugh Regio" -- lies a vast, craterless plain that appears to be no more than 100 million years old, and is possibly still being shaped by geologic processes as seen by NASA New Horizons spacecraft. This frozen region is north of Pluto's icy mountains and has been informally named Sputnik Planum (Sputnik Plain), after Earth's first artificial satellite. The surface appears to be divided into irregularly-shaped segments that are ringed by narrow troughs. Features that appear to be groups of mounds and fields of small pits are also visible. This image was acquired by the Long Range Reconnaissance Imager (LORRI) on July 14 from a distance of 48,000 miles (77,000 kilometers). Features as small as one-half mile (1 kilometer) across are visible. The blocky appearance of some features is due to compression of the image. http://photojournal.jpl.nasa.gov/catalog/PIA19841

  12. The impact of trans-catheter aortic valve replacement induced left-bundle branch block on cardiac reverse remodeling.

    PubMed

    Dobson, Laura E; Musa, Tarique A; Uddin, Akhlaque; Fairbairn, Timothy A; Bebb, Owen J; Swoboda, Peter P; Haaf, Philip; Foley, James; Garg, Pankaj; Fent, Graham J; Malkin, Christopher J; Blackman, Daniel J; Plein, Sven; Greenwood, John P

    2017-02-22

    Left bundle branch block (LBBB) is common following trans-catheter aortic valve replacement (TAVR) and has been linked to increased mortality, although whether this is related to less favourable cardiac reverse remodeling is unclear. The aim of the study was to investigate the impact of TAVR induced LBBB on cardiac reverse remodeling. 48 patients undergoing TAVR for severe aortic stenosis were evaluated. 24 patients with new LBBB (LBBB-T) following TAVR were matched with 24 patients with a narrow post-procedure QRS (nQRS). Patients underwent cardiovascular magnetic resonance (CMR) prior to and 6 m post-TAVR. Measured cardiac reverse remodeling parameters included left ventricular (LV) size, ejection fraction (LVEF) and global longitudinal strain (GLS). Inter- and intra-ventricular dyssynchrony were determined using time to peak radial strain derived from CMR Feature Tracking. In the LBBB-T group there was an increase in QRS duration from 96 ± 14 to 151 ± 12 ms (P < 0.001) leading to inter- and intra-ventricular dyssynchrony (inter: LBBB-T 130 ± 73 vs nQRS 23 ± 86 ms, p < 0.001; intra: LBBB-T 118 ± 103 vs. nQRS 13 ± 106 ms, p = 0.001). Change in indexed LV end-systolic volume (LVESVi), LVEF and GLS was significantly different between the two groups (LVESVi: nQRS -7.9 ± 14.0 vs. LBBB-T -0.6 ± 10.2 ml/m 2 , p = 0.02, LVEF: nQRS +4.6 ± 7.8 vs LBBB-T -2.1 ± 6.9%, p = 0.002; GLS: nQRS -2.1 ± 3.6 vs. LBBB-T +0.2 ± 3.2%, p = 0.024). There was a significant correlation between change in QRS and change in LVEF (r = -0.434, p = 0.002) and between change in QRS and change in GLS (r = 0.462, p = 0.001). Post-procedure QRS duration was an independent predictor of change in LVEF and GLS at 6 months. TAVR-induced LBBB is associated with less favourable cardiac reverse remodeling at medium term follow up. In view of this, every effort should be made to prevent TAVR-induced LBBB

  13. Accuracy of Heart Rate Watches: Implications for Weight Management.

    PubMed

    Wallen, Matthew P; Gomersall, Sjaan R; Keating, Shelley E; Wisløff, Ulrik; Coombes, Jeff S

    2016-01-01

    Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established. To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha) to measure heart rate and energy expenditure at rest and during exercise. Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years) completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate) and indirect calorimetry (energy expenditure). None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67-0.95 [0.35 to 0.98]) and weak to strong for energy expenditure (0.16-0.86 [-0.25 to 0.95]). All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1-9%) but greater for energy expenditure (9-43%). Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm) than energy expenditure (ranging from -266.7 to 65.7 kcals) across devices. These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss.

  14. Association between Serum Uric Acid Level and Ventricular Tachyarrhythmia in Heart Failure Patients with Implantable Cardioverter-Defibrillator.

    PubMed

    Nodera, Minoru; Suzuki, Hitoshi; Matsumoto, Yoshiyuki; Kamioka, Masashi; Kaneshiro, Takashi; Yoshihisa, Akiomi; Ohira, Tetsuya; Takeishi, Yasuchika

    2018-05-25

    The uric acid (UA) level is related to cardiac events and mortality, but little is known about the clinical significance of serum UA with regard to the ventricular tachyarrhythmia (VT) risk in patients with heart failure. The present study enrolled 56 patients with ischemic and nonischemic cardiomyopathy (37 males, mean age 64.7 ± 11.1 years) who received prophylactic implantable cardioverter-defibrillator (ICD) implantation. Based on a median serum UA value, study subjects were divided into two groups: serum UA < 6.1 mg/dL (group L, n = 29) and ≥6.1 mg/dL (group H, n = 27). Echo- and electrocardiograms (QRS duration and QTc intervals) were examined in each group. During the follow-up period (30 ± 8 months), 22 (39%) patients had appropriate ICD therapies for sustained VT. There was no significant difference in the electro- and echocardiographic data between both groups. However, appropriate ICD therapies were significantly higher in group H than in group L (p  =  0.02). In multivariate analysis, UA was an independent predictor of appropriate ICD therapies (hazard ratio 1.826, 95% confidence interval 1.248-2.671, p = 0.002). Serum UA levels might be a predictor of VT, providing new aspects regarding the decision to adapt ICD implantation in patients with heart failure. © 2018 S. Karger AG, Basel.

  15. An advanced algorithm for fetal heart rate estimation from non-invasive low electrode density recordings.

    PubMed

    Dessì, Alessia; Pani, Danilo; Raffo, Luigi

    2014-08-01

    Non-invasive fetal electrocardiography is still an open research issue. The recent publication of an annotated dataset on Physionet providing four-channel non-invasive abdominal ECG traces promoted an international challenge on the topic. Starting from that dataset, an algorithm for the identification of the fetal QRS complexes from a reduced number of electrodes and without any a priori information about the electrode positioning has been developed, entering into the top ten best-performing open-source algorithms presented at the challenge.In this paper, an improved version of that algorithm is presented and evaluated exploiting the same challenge metrics. It is mainly based on the subtraction of the maternal QRS complexes in every lead, obtained by synchronized averaging of morphologically similar complexes, the filtering of the maternal P and T waves and the enhancement of the fetal QRS through independent component analysis (ICA) applied on the processed signals before a final fetal QRS detection stage. The RR time series of both the mother and the fetus are analyzed to enhance pseudoperiodicity with the aim of correcting wrong annotations. The algorithm has been designed and extensively evaluated on the open dataset A (N = 75), and finally evaluated on datasets B (N = 100) and C (N = 272) to have the mean scores over data not used during the algorithm development. Compared to the results achieved by the previous version of the algorithm, the current version would mark the 5th and 4th position in the final ranking related to the events 1 and 2, reserved to the open-source challenge entries, taking into account both official and unofficial entrants. On dataset A, the algorithm achieves 0.982 median sensitivity and 0.976 median positive predictivity.

  16. Role of Hyperkalemia in Heart Failure and the Therapeutic Use of Potassium Binders.

    PubMed

    Sarwar, Chaudhry M S; Bhagat, Aditi A; Anker, Stefan D; Butler, Javed

    2017-01-01

    Hyperkalemia can be a life-threatening disorder, especially for at-risk patients with heart failure, chronic kidney disease, with diabetes, and patients on certain drugs like renin-angiotensin-aldosterone system antagonists and mineralocorticoid receptor antagonists. There are limited therapeutic options available for hyperkalemia, and they have narrow effectiveness because of their unfavorable side effects profile in long-term and high cost utilization requiring inpatient care. Patiromersorbitex calcium and sodium zirconium cyclosilicate are novel potassium-lowering compounds for the treatment and prevention of hyperkalemia in at-risk population. These therapeutic agents have shown encouraging results in early phase II and phase III clinical trials. However, there is need to further study their efficacy and safety in heart failure population in order to establish their clinical use. The focus of this chapter will be to promote better understanding of potassium homeostasis in heart failure patients and the mechanistic overview of novel drugs, with emphasis on heart failure population.

  17. Universal algorithm for diagnosis of biventricular capture in patients with cardiac resynchronization therapy.

    PubMed

    Jastrzebski, Marek; Kukla, Piotr; Fijorek, Kamil; Czarnecka, Danuta

    2014-08-01

    An accurate and universal method for diagnosis of biventricular (BiV) capture using a standard 12-lead electrocardiogram (ECG) would be useful for assessment of cardiac resynchronization therapy (CRT) patients. Our objective was to develop and validate such an ECG method for BiV capture diagnosis that would be independent of pacing lead positions-a major confounder that significantly influences the morphologies of paced QRS complexes. On the basis of an evaluation of 789 ECGs of 443 patients with heart failure and various right ventricular (RV) and left ventricular (LV) lead positions, the following algorithm was constructed and validated. BiV capture was diagnosed if the QRS in lead I was predominantly negative and either V1 QRS was predominantly positive or V6 QRS was of negative onset and predominantly negative (step 1), or if QRS complex duration was <160 ms (step 2). All other ECGs were classified as loss of LV capture. The algorithm showed good accuracy (93%), sensitivity (97%), and specificity (90%) for detection of loss of LV capture. The performance of the algorithm did not differ among apical, midseptal, and outflow tract RV lead positions and various LV lead positions. LV capture leaves diagnostic hallmarks in the fused BiV QRS related to different vectors of depolarization and more rapid depolarization of the ventricles. An accurate two-step ECG algorithm for BiV capture diagnosis was developed and validated. This algorithm is universally applicable to all CRT patients, regardless of the positions of the pacing leads. ©2014 Wiley Periodicals, Inc.

  18. Narrow Networks on the Individual Marketplace in 2017.

    PubMed

    Polski, Daniel; Weiner, Janet; Zhang, Yuehan

    2017-09-01

    This Issue Brief describes the breadth of physician networks on the ACA marketplaces in 2017. We find that the overall rate of narrow networks is 21%, which is a decline since 2014 (31%) and 2016 (25%). Narrow networks are concentrated in plans sold on state-based marketplaces, at 42%, compared to 10% of plans on federally-facilitated marketplaces. Issuers that have traditionally offered Medicaid coverage have the highest prevalence of narrow network plans at 36%, with regional/local plans and provider-based plans close behind at 27% and 30%. We also find large differences in narrow networks by state and by plan type.

  19. Vasodilators and α-adrenoceptor antagonists in hypertension and heart failure

    PubMed Central

    Taylor, S. H.

    1981-01-01

    1 The mechanism of the increase in arteriolar resistance in hypertension and heart failure is differently derived. In hypertension, venous compliance is normal and the concentric narrowing of the arteriolar resistance vessels is `anatomical'; it is not due to increased stimulation or enhanced sensitivity of the vascular smooth muscle. In heart failure narrowing of both the arteriolar resistance and venous capacitance vessels derives predominantly from increased sympathoadrenal stimulation of α1-adrenoceptors in the vascular smooth muscle. 2 Vasodilator drugs which relax vascular smooth muscle differ widely in their site of activity. None are entirely specific for arteries, arterioles or veins, but they may be grouped for therapeutic convenience into those predominantly acting on arterioles (for example hydralazine) and those acting on veins (for example nitrates). 3 Control of the resting blood pressure in stable essential hypertension appears to be equally well achieved with non-specific arteriolar dilators (for example hydralazine, minoxidil, calcium antagonists) as those with specific α1-adrenoceptor blocking properties (for example prazosin, indoramin). Pressure surges due to dynamic exercise and mental stress are little influenced by either category of drug. In contrast, α-adrenoceptor antagonists appear to be capable of partly suppressing increase in ambulatory pressure and the pressor responses to isometric exercise and cold, particularly in patients pre-treated with β-blocking drugs. 4 In acute heart failure, non-selective α-blocking drugs (for example phentolamine) produce an equal reduction in left ventricular filling pressure but greater increase in cardiac output than vasodilator drugs with a more balanced relaxing effect on arterioles and venules. 5 In chronic heart failure, the little information available indicates that non-selective arteriolar dilatation is probably associated with a greater increase in cardiac output lesser reduction in left

  20. Association between obesity and ECG variables in children and adolescents: A cross-sectional study.

    PubMed

    Sun, Guo-Zhe; Li, Yang; Zhou, Xing-Hu; Guo, Xiao-Fan; Zhang, Xin-Gang; Zheng, Li-Qiang; Li, Yuan; Jiao, Yun-DI; Sun, Ying-Xian

    2013-12-01

    Obesity exhibits a wide variety of electrocardiogram (ECG) abnormalities in adults, which often lead to cardiovascular events. However, there is currently no evidence of an association between obesity and ECG variables in children and adolescents. The present study aimed to explore the associations between obesity and ECG intervals and axes in children and adolescents. A cross-sectional observational study of 5,556 students aged 5-18 years was performed. Anthropometric data, blood pressure and standard 12-lead ECGs were collected for each participant. ECG variables were measured manually based on the temporal alignment of simultaneous 12 leads using a CV200 ECG Work Station. Overweight and obese groups demonstrated significantly longer PR intervals, wider QRS durations and leftward shifts of frontal P-wave, QRS and T-wave axes, while the obese group also demonstrated significantly higher heart rates, compared with normal weight groups within normotensive or hypertensive subjects (P<0.05). Abdominal obesity was also associated with longer PR intervals, wider QRS duration and a leftward shift of frontal ECG axes compared with normal waist circumference (WC) within normotensive or hypertensive subjects (P<0.05). Gender was a possible factor affecting the ECG variables. Furthermore, the ECG variables, including PR interval, QRS duration and frontal P-wave, QRS and T-wave axes, were significantly linearly correlated with body mass index, WC and waist-to-height ratio adjusted for age, gender, ethnicity and blood pressure. However, there was no significant association between obesity and the corrected QT interval (P>0.05). The results of the current study indicate that in children and adolescents, general and abdominal obesity is associated with longer PR intervals, wider QRS duration and a leftward shift of frontal P-wave, QRS and T-wave axes, independent of age, gender, ethnicity and blood pressure.

  1. The Role of Echocardiography in the Optimization of Cardiac Resynchronization Therapy: Current Evidence and Future Perspectives.

    PubMed

    Spartalis, Michael; Tzatzaki, Eleni; Spartalis, Eleftherios; Damaskos, Christos; Athanasiou, Antonios; Livanis, Efthimios; Voudris, Vassilis

    2017-01-01

    Cardiac resynchronization therapy (CRT) has become a mainstay in the management of heart failure. Up to one-third of patients who received resynchronization devices do not experience the full benefits of CRT. The clinical factors influencing the likelihood to respond to the therapy are wide QRS complex, left bundle branch block, female gender, non-ischaemic cardiomyopathy (highest responders), male gender, ischaemic cardiomyopathy (moderate responders) and narrow QRS complex, non-left bundle branch block (lowest, non-responders). This review provides a conceptual description of the role of echocardiography in the optimization of CRT. A literature survey was performed using PubMed database search to gather information regarding CRT and echocardiography. A total of 70 studies met selection criteria for inclusion in the review. Echocardiography helps in the initial selection of the patients with dyssynchrony, which will benefit the most from optimal biventricular pacing and provides a guide to left ventricular (LV) lead placement during implantation. Different echocardiographic parameters have shown promise and can offer the possibility of patient selection, response prediction, lead placement optimization strategies and optimization of device configurations. LV ejection fraction along with specific electrocardiographic criteria remains the cornerstone of CRT patient selection. Echocardiography is a non-invasive, cost-effective, highly reproducible method with certain limitations and accuracy that is affected by measurement errors. Echocardiography can assist with the identification of the appropriate electromechanical substrate of CRT response and LV lead placement. The targeted approach can improve the haemodynamic response, as also the patient-specific parameters estimation.

  2. The Role of Echocardiography in the Optimization of Cardiac Resynchronization Therapy: Current Evidence and Future Perspectives

    PubMed Central

    Spartalis, Michael; Tzatzaki, Eleni; Spartalis, Eleftherios; Damaskos, Christos; Athanasiou, Antonios; Livanis, Efthimios; Voudris, Vassilis

    2017-01-01

    Background: Cardiac resynchronization therapy (CRT) has become a mainstay in the management of heart failure. Up to one-third of patients who received resynchronization devices do not experience the full benefits of CRT. The clinical factors influencing the likelihood to respond to the therapy are wide QRS complex, left bundle branch block, female gender, non-ischaemic cardiomyopathy (highest responders), male gender, ischaemic cardiomyopathy (moderate responders) and narrow QRS complex, non-left bundle branch block (lowest, non-responders). Objective: This review provides a conceptual description of the role of echocardiography in the optimization of CRT. Method: A literature survey was performed using PubMed database search to gather information regarding CRT and echocardiography. Results: A total of 70 studies met selection criteria for inclusion in the review. Echocardiography helps in the initial selection of the patients with dyssynchrony, which will benefit the most from optimal biventricular pacing and provides a guide to left ventricular (LV) lead placement during implantation. Different echocardiographic parameters have shown promise and can offer the possibility of patient selection, response prediction, lead placement optimization strategies and optimization of device configurations. Conclusion: LV ejection fraction along with specific electrocardiographic criteria remains the cornerstone of CRT patient selection. Echocardiography is a non-invasive, cost-effective, highly reproducible method with certain limitations and accuracy that is affected by measurement errors. Echocardiography can assist with the identification of the appropriate electromechanical substrate of CRT response and LV lead placement. The targeted approach can improve the haemodynamic response, as also the patient-specific parameters estimation. PMID:29387277

  3. Time Course of Electrical Remodeling of Native Conduction After Cardiac Resynchronization Therapy and Its Impact on Clinical Outcome.

    PubMed

    Cvijić, Marta; Žižek, David; Antolič, Bor; Zupan, Igor

    2017-03-01

    Cardiac resynchronization therapy (CRT) induces structural and electrical remodeling (ER) in heart failure (HF) patients. Our aim was to assess time course of ER of native conduction and mechanical remodeling after CRT and impact of CRT-induced ER on clinical outcome. We prospectively included 62 patients (aged 66 ± 10 years). Echocardiographic and ECG parameters were measured at baseline and 1, 3, 6, 9, and 12 months after implantation. Biventricular pacing was temporary inhibited during each follow-up to record intrinsic ECG. ER was defined as a decrease in native pre-implantation QRS duration ≥10 ms. During follow-up HF hospitalizations, cardiovascular death and transplantation (combined end point) were recorded. There were significant changes in intrinsic ECG parameters during follow-up; the narrowing of QRS duration was already observed after 1 month (median 185 ms [interquartile range (IQR) 175-194] vs 180 ms [170-194]; P < .001). Left ventricular (LV) volumes decreased only after 3 months of CRT (median end-systolic volume 167 mL [137-206] vs 140 mL [112-196]; P < .001). Only patients with ER (n = 24) exhibited significant mechanical remodeling and showed superior survival free from the combined end point compared with patients without ER (log-rank P = .028). Electrical remodeling of native conduction precedes detectable left ventricular structural changes after CRT. ER of native conduction is associated with better clinical outcome following CRT. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Accuracy of Heart Rate Watches: Implications for Weight Management

    PubMed Central

    2016-01-01

    Background Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established. Aim To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha) to measure heart rate and energy expenditure at rest and during exercise. Methods Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years) completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate) and indirect calorimetry (energy expenditure). Results None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67–0.95 [0.35 to 0.98]) and weak to strong for energy expenditure (0.16–0.86 [-0.25 to 0.95]). All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1–9%) but greater for energy expenditure (9–43%). Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm) than energy expenditure (ranging from -266.7 to 65.7 kcals) across devices. Conclusion These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss. PMID:27232714

  5. Ring resonator based narrow-linewidth semiconductor lasers

    NASA Technical Reports Server (NTRS)

    Ksendzov, Alexander (Inventor)

    2005-01-01

    The present invention is a method and apparatus for using ring resonators to produce narrow linewidth hybrid semiconductor lasers. According to one embodiment of the present invention, the narrow linewidths are produced by combining the semiconductor gain chip with a narrow pass band external feedback element. The semi conductor laser is produced using a ring resonator which, combined with a Bragg grating, acts as the external feedback element. According to another embodiment of the present invention, the proposed integrated optics ring resonator is based on plasma enhanced chemical vapor deposition (PECVD) SiO.sub.2 /SiON/SiO.sub.2 waveguide technology.

  6. Differentiating Electromechanical From Non-Electrical Substrates of Mechanical Discoordination to Identify Responders to Cardiac Resynchronization Therapy.

    PubMed

    Lumens, Joost; Tayal, Bhupendar; Walmsley, John; Delgado-Montero, Antonia; Huntjens, Peter R; Schwartzman, David; Althouse, Andrew D; Delhaas, Tammo; Prinzen, Frits W; Gorcsan, John

    2015-09-01

    Left ventricular (LV) mechanical discoordination, often referred to as dyssynchrony, is often observed in patients with heart failure regardless of QRS duration. We hypothesized that different myocardial substrates for LV mechanical discoordination exist from (1) electromechanical activation delay, (2) regional differences in contractility, or (3) regional scar and that we could differentiate electromechanical substrates responsive to cardiac resynchronization therapy (CRT) from unresponsive non-electrical substrates. First, we used computer simulations to characterize mechanical discoordination patterns arising from electromechanical and non-electrical substrates and accordingly devise the novel systolic stretch index (SSI), as the sum of posterolateral systolic prestretch and septal systolic rebound stretch. Second, 191 patients with heart failure (QRS duration ≥120 ms; LV ejection fraction ≤35%) had baseline SSI quantified by automated echocardiographic radial strain analysis. Patients with SSI≥9.7% had significantly less heart failure hospitalizations or deaths 2 years after CRT (hazard ratio, 0.32; 95% confidence interval, 0.19-0.53; P<0.001) and less deaths, transplants, or LV assist devices (hazard ratio, 0.28; 95% confidence interval, 0.15-0.55; P<0.001). Furthermore, in a subgroup of 113 patients with intermediate electrocardiographic criteria (QRS duration of 120-149 ms or non-left bundle branch block), SSI≥9.7% was independently associated with significantly less heart failure hospitalizations or deaths (hazard ratio, 0.41; 95% confidence interval, 0.23-0.79; P=0.004) and less deaths, transplants, or LV assist devices (hazard ratio, 0.27; 95% confidence interval, 0.12-0.60; P=0.001). Computer simulations differentiated patterns of LV mechanical discoordination caused by electromechanical substrates responsive to CRT from those related to regional hypocontractility or scar unresponsive to CRT. The novel SSI identified patients who benefited more

  7. Ocular Biometrics of Myopic Eyes With Narrow Angles.

    PubMed

    Chong, Gabriel T; Wen, Joanne C; Su, Daniel Hsien-Wen; Stinnett, Sandra; Asrani, Sanjay

    2016-02-01

    The purpose of this study was to compare the ocular biometrics between myopic patients with and without narrow angles. Patients with a stable myopic refraction (myopia worse than -1.00 D spherical equivalent) were prospectively recruited. Angle status was assessed using gonioscopy and biometric measurements were performed using an anterior segment optical coherence tomography and an IOLMaster. A total of 29 patients (58 eyes) were enrolled with 13 patients (26 eyes) classified as having narrow angles and 16 patients (32 eyes) classified as having open angles. Baseline demographics of age, sex, and ethnicity did not differ significantly between the 2 groups. The patients with narrow angles were on average older than those with open angles but the difference did not reach statistical significance (P=0.12). The central anterior chamber depth was significantly less in the eyes with narrow angles (P=0.05). However, the average lens thickness, although greater in the eyes with narrow angles, did not reach statistical significance (P=0.10). Refractive error, axial lengths, and iris thicknesses did not differ significantly between the 2 groups (P=0.32, 0.47, 0.15). Narrow angles can occur in myopic eyes. Routine gonioscopy is therefore recommended for all patients regardless of refractive error.

  8. Detection of heart rate and rhythm with a smartphone-based electrocardiograph versus a reference standard electrocardiograph in dogs and cats.

    PubMed

    Kraus, Marc S; Gelzer, Anna R; Rishniw, Mark

    2016-07-15

    OBJECTIVE To evaluate the diagnostic utility of ECGs acquired with a smartphone-based device, compared with reference 6-lead ECGs, for identification of heart rate and rhythm in dogs and cats. DESIGN Prospective study. ANIMALS 51 client-owned dogs and 27 client-owned cats. PROCEDURES Patients examined by a small animal referral cardiology service between April 2012 and January 2013 were enrolled consecutively. In each patient, a 30-second ECG was simultaneously acquired with a smartphone-based device (a bipolar, single-lead recorder coupled to a smartphone with an ECG application) and a standard 6-lead ECG machine. Recordings were evaluated by 3 board-certified cardiologists, and intra- and interobserver agreement were evaluated for both rhythm diagnosis and QRS polarity identification. RESULTS Values for instantaneous and mean heart rates for the smartphone-acquired and reference ECGs were within 1 beat of each other when mean heart rates were calculated. Intraobserver agreement for rhythm assessment was very high, with maximum disagreement for any observer for only 2 of 51 dogs and only 4 of 27 cats. There was minimal disagreement in the polarity of depolarization between the smartphone-acquired and reference ECGs in dogs but frequent disagreement in cats. Interobserver agreement for smartphone-acquired ECGs was similar to that for reference ECGs. with all 3 observers agreeing on the rhythm analysis and minimal disagreement on polarity. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that ECGs acquired with the smartphone-based device accurately identified heart rate and rhythm in dogs and cats. Thus, the device may allow veterinarians to evaluate and manage cardiac arrhythmias relatively inexpensively at the cage side and could also allow clinicians to rapidly share information via email for further consultation, potentially enhancing patient care.

  9. Variability in heart rate recovery measurements over 1 year in healthy, middle-aged adults.

    PubMed

    Mellis, M G; Ingle, L; Carroll, S

    2014-02-01

    This study assessed the longer-term (12-month) variability in post-exercise heart rate recovery following a submaximal exercise test. Longitudinal data was analysed for 97 healthy middle-aged adults (74 male, 23 female) from 2 occasions, 12 months apart. Participants were retrospectively selected if they had stable physical activity habits, submaximal treadmill fitness and anthropometric measurements between the 2 assessment visits. A submaximal Bruce treadmill test was performed to at least 85% age-predicted maximum heart rate. Absolute heart rate and Δ heart rate recovery (change from peak exercise heart rate) were recorded for 1 and 2 min post-exercise in an immediate supine position. Heart rate recovery at both time-points was shown to be reliable with intra-class correlation coefficient values ≥ 0.714. Absolute heart rate 1-min post-exercise showed the strongest agreement between repeat tests (r = 0.867, P < 0.001). Lower coefficient of variation (≤ 10.2%) and narrower limits of agreement were found for actual heart rate values rather than Δ heart rate recovery, and for 1-min rather than 2-min post-exercise recovery time points. Log-transformed values generated better variability with acceptable coefficient of variation for all measures (2.2-10%). Overall, 1 min post-exercise heart rate recovery data had least variability over the 12-month period in apparently healthy middle-aged adults. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Fetal Heart Rate Monitoring Using Maternal Abdominal Surface Electrodes in Third Trimester: Can We Obtain Additional Information Other than CTG Trace?

    PubMed

    Fuchs, Tomasz; Grobelak, Krzysztof; Pomorski, Michał; Zimmer, Mariusz

    2016-01-01

    Cardiotocography (CTG) is the most widely used procedure despite its low specificity for fetal acidosis and poor perinatal outcome. Fetal electrocardiography (fECG) with transabdominal electrodes is a new, non-invasive and promising method with greater potential for detecting impairment of fetal circulation. This study is the first that attempts to assess the usefulness of fECG in comparison to CTG during antepartum period. To determine if a single fECG examination along with CTG tracing and Doppler flow measurement in the fetal vessels has any additional clinical value in normal and intrauterine growth restricted (IUGR) fetuses. The study included 93 pregnancies with IUGR, 37 pregnancies with IUGR and brain sparing effect, and 324 healthy pregnant women. The T/QRS ratio, cerebro-placental ratio (CRP), and CTG tracings were analyzed. One-way analysis of variance and Spearman's rank correlation coefficient were applied. The relationship between results of the T/QRS ratio and CTG examination among the study groups was analyzed. The highest average mean value of the T/QRS ratio was recorded in the IUGR group with a normal CPR and a pathologic CTG (0.235 ± 0.014). The highest average maximum values were observed in the groups of IUGR pregnancies with a reduced CPR with normal (0.309 ± 0.100), suspicious (0.330 ± 0.102) and pathologic (0.319 ± 0.056) CTGs. Analysis of variance revealed differences between study groups regarding maximum values and the difference between maximum and minimal values of T/QRS. Correlations between groups were insignificant. Higher values of T/QRS ratio in IUGR pregnancies with normal and reduced CPR than in control group regardless of the result of CTG examination may indicate minimal worsening of intrauterine fetal well-being in growth retarded fetuses. No relationship between fECG examination and CTG tracings suggests that a single fECG does not provide any additional clinically significant information determining the condition of the

  11. Dynamics and rate-dependence of the spatial angle between ventricular depolarization and repolarization wave fronts during exercise ECG.

    PubMed

    Kenttä, Tuomas; Karsikas, Mari; Kiviniemi, Antti; Tulppo, Mikko; Seppänen, Tapio; Huikuri, Heikki V

    2010-07-01

    QRS/T angle and the cosine of the angle between QRS and T-wave vectors (TCRT), measured from standard 12-lead electrocardiogram (ECG), have been used in risk stratification of patients. This study assessed the possible rate dependence of these variables during exercise ECG in healthy subjects. Forty healthy volunteers, 20 men and 20 women, aged 34.6 +/- 3.4, underwent an exercise ECG testing. Twelve-lead ECG was recorded from each test subject and the spatial QRS/T angle and TCRT were automatically analyzed in a beat-to-beat manner with custom-made software. The individual TCRT/RR and QRST/RR patterns were fitted with seven different regression models, including a linear model and six nonlinear models. TCRT and QRS/T angle showed a significant rate dependence, with decreased values at higher heart rates (HR). In individual subjects, the second-degree polynomic model was the best regression model for TCRT/RR and QRST/RR slopes. It provided the best fit for both exercise and recovery. The overall TCRT/RR and QRST/RR slopes were similar between men and women during exercise and recovery. However, women had predominantly higher TCRT and QRS/T values. With respect to time, the dynamics of TCRT differed significantly between men and women; with a steeper exercise slope in women (women, -0.04/min vs -0.02/min in men, P < 0.0001). In addition, evident hysteresis was observed in the TCRT/RR slopes; with higher TCRT values during exercise. The individual patterns of TCRT and QRS/T angle are affected by HR and gender. Delayed rate adaptation creates hysteresis in the TCRT/RR slopes.

  12. Narrow-linewidth Q-switched random distributed feedback fiber laser.

    PubMed

    Xu, Jiangming; Ye, Jun; Xiao, Hu; Leng, Jinyong; Wu, Jian; Zhang, Hanwei; Zhou, Pu

    2016-08-22

    A narrow-linewidth Q-switched random fiber laser (RFL) based on a half-opened cavity, which is realized by narrow-linewidth fiber Bragg grating (FBG) and a section of 3 km passive fiber, has been proposed and experimentally investigated. The narrow-linewidth lasing is generated by the spectral filtering of three FBGs with linewidth of 1.21 nm, 0.56 nm, and 0.12 nm, respectively. The Q switching of the distributed cavity is achieved by placing an acousto-optical modulator (AOM) between the FBG and the passive fiber. The maximal output powers of the narrow-linewidth RFLs with the three different FBGs are 0.54 W, 0.27 W, and 0.08 W, respectively. Furthermore, the repetition rates of the output pulses are 500 kHz, and the pulse durations are about 500 ns. The corresponding pulse energies are about 1.08 μJ, 0.54 μJ, and 0.16 μJ, accordingly. The linewidth of FBG can influence the output characteristics in full scale. The narrower the FBG, the higher the pump threshold; the lower the output power at the same pump level, the more serious the linewidth broadening; and thus the higher the proportion of the CW-ground exists in the output pulse trains. Thanks to the assistance of the band-pass filter (BPF), the proportion of the CW-ground of narrow-linewidth Q-switched RFL under the relative high-pump-low-output condition can be reduced effectively. The experimental results indicate that it is challenging to demonstrate a narrow-linewidth Q-switched RFL with high quality output. But further power scaling and linewidth narrowing is possible in the case of operating parameters, optimization efforts, and a more powerful pump source. To the best of our knowledge, this is the first demonstration of narrow-linewidth generation in a Q-switched RFL.

  13. Discovery of a narrow line quasar

    NASA Technical Reports Server (NTRS)

    Stocke, J.; Liebert, J.; Maccacaro, T.; Griffiths, R. E.; Steiner, J. E.

    1982-01-01

    A stellar object is reported which, while having X-ray and optical luminosities typical of quasars, has narrow permitted and forbidden emission lines over the observed spectral range. The narrow-line spectrum is high-excitation, the Balmer lines seem to be recombinational, and a redder optical spectrum than that of most quasars is exhibited, despite detection as a weak radio source. The object does not conform to the relationships between H-beta parameters and X-ray flux previously claimed for a large sample of the active galactic nuclei. Because reddish quasars with narrow lines, such as the object identified, may not be found by the standard techniques for the discovery of quasars, the object may be a prototype of a new class of quasars analogous to high-luminosity Seyfert type 2 galaxies. It is suggested that these objects cannot comprise more than 10% of all quasars.

  14. Infants Experience Perceptual Narrowing for Nonprimate Faces

    ERIC Educational Resources Information Center

    Simpson, Elizabeth A.; Varga, Krisztina; Frick, Janet E.; Fragaszy, Dorothy

    2011-01-01

    Perceptual narrowing--a phenomenon in which perception is broad from birth, but narrows as a function of experience--has previously been tested with primate faces. In the first 6 months of life, infants can discriminate among individual human and monkey faces. Though the ability to discriminate monkey faces is lost after about 9 months, infants…

  15. The effect of sport on computerized electrocardiogram measurements in college athletes.

    PubMed

    Gademan, Maaike G J; Uberoi, Abhimanyu; Le, Vy-Van; Mandic, Sandra; van Oort, Eddy R; Myers, Jonathan; Froelicher, Victor F

    2012-02-01

    Broad criteria for abnormal electrocardiogram (ECG) findings, requiring additional testing, have been recommended for preparticipation exams (PPE) of athletes. As these criteria have not considered the sport in which athletes participate, we examined the effect of sports on the computerized ECG measurements obtained in college athletes. During the Stanford 2007 PPE, computerized 12-lead ECGs (Schiller AG) were obtained in 641 athletes (350 male/291 female, age 19.5 ± 2 years). Athletes were engaged in 22 different sports and were grouped into 16 categories: baseball/softball, basketball, crew, crosscountry, fencing, field events, football linemen, football other positions, golf, gymnastics, racquet sports, sailing, track/field, volleyball, water sports, and wrestling. The analysis focused on ECG leads V2, aVF and V5 which provide a three-dimensional representation of the heart's electrical activity. As marked ECG differences exist between males and females, the data are presented by gender. In males, ANOVA analysis yielded significant ECG differences between sports for heart rate, QRS duration, QTc, J-amplitude in V2 and V5, spatial vector length (SVL) of the P wave, SVL R wave, and SVL T wave, and RS(sum) (p < 0.05). In females ECG differences between sports were found for heart rate, QRS duration, QRS axis and SVL T wave (p < 0.05). Poor correlations were found between body dimensions and ECG measurements (r < 0.50). Significant ECG changes exist between college athletes participating in different sports, and these differences were more apparent in males than females. Therefore, sport-specific ECG criteria for abnormal ECG findings should be developed to obtain a more useful approach to ECG screening in athletes.

  16. Presetting ECG electrodes for earlier heart rate detection in the delivery room.

    PubMed

    Gulati, Rashmi; Zayek, Michael; Eyal, Fabien

    2018-07-01

    To determine whether heart rate (HR) could be detected earlier than by pulse oximeter (POX), using a novel method of application of electrocardiogram (ECG) electrodes during neonatal resuscitation in the delivery room. ECG electrodes were set before delivery to be applied to the back of infants' thorax. Time to detect HR was recorded as soon as a numerical HR along with a recognizable and persistent QRS complex was observed on ECG monitor (HRECG) and a plethysmographic waveform was seen on POX monitor (HRPOX). Out of 334 infants, 49 were <31 weeks of gestational age. Overall, the median (interquartile range, IQR) time to detect HRECG was significantly shorter [29 (5, 60) seconds] than time by POX [60 (45,120) seconds], (p < 0.001). Similarly, in <31-week infants, the median (IQR) time to detect HRECG was 10 (2, 40) seconds compared to 60 (30,120) seconds by POX, (p < 0.001). Failure to have HR detected by 1 minute occurred in 30%, 54% and 20% of infants by ECG, POX and either of the devices, respectively. In the delivery room, electrodes applied by the study method are more effective than pulse oximetry in providing the neonatal team with timely HR information that is necessary for proper resuscitative actions. Published by Elsevier B.V.

  17. Non-responders to cardiac resynchronization therapy: Insights from multimodality imaging and electrocardiography. A brief review.

    PubMed

    Carità, Patrizia; Corrado, Egle; Pontone, Gianluca; Curnis, Antonio; Bontempi, Luca; Novo, Giuseppina; Guglielmo, Marco; Ciaramitaro, Gianfranco; Assennato, Pasquale; Novo, Salvatore; Coppola, Giuseppe

    2016-12-15

    Cardiac resynchronization therapy (CRT) is a successful strategy for heart failure (HF) patients. The pre-requisite for the response is the evidence of electrical dyssynchrony on the surface electrocardiogram usually as left bundle branch block (LBBB). Non-response to CRT is a significant problem in clinical practice. Patient selection, inadequate delivery and sub-optimal left ventricle lead position may be important causes. In an effort to improve CRT response multimodality imaging (especially echocardiography, computed tomography and cardiac magnetic resonance) could play a decisive role and extensive literature has been published on the matter. However, we are so far from routinary use in clinical practice. Electrocardiography (with respect to left ventricle capture and QRS narrowing) may represent a simple and low cost approach for early prediction of potential non-responder, with immediate practical implications. This brief review covers the current recommendations for CRT in HF patients with particular attention to the potential benefits of multimodality imaging and electrocardiography in improving response rate. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. [Continuous registration of micropotentials of the human heart. Initial experiences with a new high resolution ECG amplifier system].

    PubMed

    Hombach, V; Kebbel, U; Höpp, H W; Winter, U J; Braun, V; Deutsch, H; Hirche, H; Hilger, H H

    1982-12-24

    A new ECG-amplifier system for recording cardiac microvolt potentials from the body surface is described. The improvement in signal-to-noise ratio was achieved by using specially designed suction electrodes, which were isolated from each other; by applying parallel signal averaging from four electrode pairs via four low-noise amplifiers; and by conducting the registration in Faraday cage. in 14 normal subjects, 12 patients with coronary heart disease and one patient with surgically corrected ventricular septal defect and pulmonary stenosis, pre-P-potentials (possible sinus node activity), His bundle potentials and ventricular late potentials were recorded with differing degrees of success. Variations of the time intervals to the preceding QRS complex were observed within the S-T segment in six of nine patients with demonstrable ventricular late ventricular late potentials. The advantage of such continuously recording ECG system lies in the highly accurate registration of cardiac micropotentials, particularly with ventricular late potentials that are changing in time, whereas the signal-averaging technique does not provide such possibilities.

  19. [The Lived Experience of Patients with Heart Transplantation: A Phenomenological Study].

    PubMed

    Hwang, Younghui; Yi, Myungsun

    2017-02-01

    The purpose of this study was to describe the lived experience of patients with heart transplantation in Korea. Individual indepth interviews and a focus group interview were used to collect the data from nine patients who had heart transplantations in 2015. All interviews were audio-taped and verbatim transcripts were made for the analysis. Data were analyzed using Colaizzi's phenomenological method. Among the nine participants, eight were men. Mean age was 57.30 years. Six theme clusters emerged from the analysis. 'Joy of rebirth obtained by good luck' describes the pleasure and expectation of new life after narrow survival. 'Suffering from adverse drug effects' illustrates various psychosocial difficulties, such as low self-esteem, helplessness, alienation, and burnout, arising from the side effects of medications. 'Body and mind of being bewildered' illustrates disintegrated health and haunting fear of death. 'Alienation disconnected with society' describes isolated feeling of existence due to misunderstandings from society. 'Suffering overcome with gratitude and responsibility' includes overcoming experience through various social supports and suitable jobs. Finally, 'acceptance of suffering accompanied with new heart' illustrate changed perspective of life itself. The findings in this study provide deep understanding and insights of the lived experience of heart related illness for these patients and should help in the development of tailored-interventions for patients with heart transplantation. © 2017 Korean Society of Nursing Science

  20. Development of heart failure is independent of K+ channel-interacting protein 2 expression

    PubMed Central

    Speerschneider, Tobias; Grubb, Søren; Metoska, Artina; Olesen, Søren-Peter; Calloe, Kirstine; Thomsen, Morten B

    2013-01-01

    Abnormal ventricular repolarization in ion channelopathies and heart disease is a major cause of ventricular arrhythmias and sudden cardiac death. K+ channel-interacting protein 2 (KChIP2) expression is significantly reduced in human heart failure (HF), contributing to a loss of the transient outward K+ current (Ito). We aim to investigate the possible significance of a changed KChIP2 expression on the development of HF and proarrhythmia. Transverse aortic constrictions (TAC) and sham operations were performed in wild-type (WT) and KChIP2−/− mice. Echocardiography was performed before and every 2 weeks after the operation. Ten weeks post-surgery, surface ECG was recorded and we paced the heart in vivo to induce arrhythmias. Afterwards, tissue from the left ventricle was used for immunoblotting. Time courses of HF development were comparable in TAC-operated WT and KChIP2−/− mice. Ventricular protein expression of KChIP2 was reduced by 70% after 10 weeks TAC in WT mice. The amplitudes of the J and T waves were enlarged in KChIP2−/− control mice. Ventricular effective refractory period, RR, QRS and QT intervals were longer in mice with HF compared to sham-operated mice of either genotype. Pacing-induced ventricular tachycardia (VT) was observed in 5/10 sham-operated WT mice compared with 2/10 HF WT mice with HF. Interestingly, and contrary to previously published data, sham-operated KChIP2−/− mice were resistant to pacing-induced VT resulting in only 1/10 inducible mice. KChIP2−/− with HF mice had similar low vulnerability to inducible VT (1/9). Our results suggest that although KChIP2 is downregulated in HF, it is not orchestrating the development of HF. Moreover, KChIP2 affects ventricular repolarization and lowers arrhythmia susceptibility. Hence, downregulation of KChIP2 expression in HF may be antiarrhythmic in mice via reduction of the fast transient outward K+ current. PMID:24099801

  1. Gene-environment interaction between SCN5A-1103Y and hypokalemia influences QT interval prolongation in African Americans: the Jackson Heart Study.

    PubMed

    Akylbekova, Ermeg L; Payne, John P; Newton-Cheh, Christopher; May, Warren L; Fox, Ervin R; Wilson, James G; Sarpong, Daniel F; Taylor, Herman A; Maher, Joseph F

    2014-01-01

    African-American ancestry, hypokalemia, and QT interval prolongation on the electrocardiogram are all risk factors for sudden cardiac death (SCD), but their interactions remain to be characterized. SCN5A-1103Y is a common missense variant, of African ancestry, of the cardiac sodium channel gene. SCN5A-1103Y is known to interact with QT-prolonging factors to promote ventricular arrhythmias in persons at high risk for SCD, but its clinical impact in the general African-American population has not been established. We genotyped SCN5A-S1103Y in 4,476 participants of the Jackson Heart Study, a population-based cohort of African Americans. We investigated the effect of SCN5A-1103Y, including interaction with hypokalemia, on QT interval prolongation, a widely-used indicator of prolonged myocardial repolarization and predisposition to SCD. We then evaluated the two sub-components of the QT interval: QRS duration and JT interval. The carrier frequency for SCN5A-1103Y was 15.4%. SCN5A-1103Y was associated with QT interval prolongation (2.7 milliseconds; P < .001) and potentiated the effect of hypokalemia on QT interval prolongation (14.6 milliseconds; P = .02). SCN5A-1103Y had opposing effects on the two sub-components of the QT interval, with shortening of QRS duration (-1.5 milliseconds; P = .001) and prolongation of the JT interval (3.4 milliseconds; P < .001). Hypokalemia was associated with diuretic use (78%; P < .001). SCN5A-1103Y potentiates the effect of hypokalemia on prolonging myocardial repolarization in the general African-American population. These findings have clinical implications for modification of QT prolonging factors, such as hypokalemia, in the 15% of African Americans who are carriers of SCN5A-1103Y. © 2014.

  2. Narrow-Line Seyfert 1 Galaxies

    NASA Technical Reports Server (NTRS)

    Leighly, Karen M.

    2000-01-01

    The primary work during this year has been the analysis and interpretation of our HST spectra from two extreme Narrow-line Seyfert 1 galaxies (NLS1s) Infrared Astronomy Satellite (IRAS) 13224-3809 and 1H 0707-495. This work has been presented as an invited talk at the workshop entitled "Observational and theoretical progress in the Study of Narrow-line Seyfert 1 Galaxies" held in Bad Honnef, Germany December 8-11, as a contributed talk at the January 2000 AAS meeting in Atlanta, Georgia, and as a contributed talk at the workshop "Probing the Physics of Active Galactic Nuclei by Multiwavelength Monitoring" held at Goddard Space Flight Center June 20-22, 2000.

  3. Combination Chemotherapy with Suboptimal Doses of Benznidazole and Pentoxifylline Sustains Partial Reversion of Experimental Chagas' Heart Disease

    PubMed Central

    Vilar-Pereira, Glaucia; Resende Pereira, Isabela; de Souza Ruivo, Leonardo Alexandre; Cruz Moreira, Otacilio; da Silva, Andrea Alice; Britto, Constança

    2016-01-01

    Chronic chagasic cardiomyopathy (CCC) progresses with parasite persistence, fibrosis, and electrical alterations associated with an unbalanced immune response such as high plasma levels of tumor necrosis factor (TNF) and nitric oxide (NO). Presently, the available treatments only mitigate the symptoms of CCC. To improve CCC prognosis, we interfered with the parasite load and unbalanced immune response using the trypanocidal drug benznidazole (Bz) and the immunoregulator pentoxifylline (PTX). C57BL/6 mice chronically infected with the Colombian strain of Trypanosoma cruzi and with signs of CCC were treated for 30 days with a suboptimal dose of Bz (25 mg/kg of body weight), PTX (20 mg/kg), or their combination (Bz plus PTX) and analyzed for electrocardiographic, histopathological, and immunological changes. Bz (76%) and Bz-plus-PTX (79%) therapies decreased parasite loads. Although the three therapies reduced myocarditis and fibrosis and ameliorated electrical alterations, only Bz plus PTX restored normal heart rate-corrected QT (QTc) intervals. Bz-plus-PTX-treated mice presented complementary effects of Bz and PTX, which reduced TNF expression (37%) in heart tissue and restored normal TNF receptor 1 expression on CD8+ T cells, respectively. Bz (85%) and PTX (70%) therapies reduced the expression of inducible nitric oxide synthase (iNOS/NOS2) in heart tissue, but only Bz (58%) reduced NO levels in serum. These effects were more pronounced after Bz-plus-PTX therapy. Moreover, 30 to 50 days after treatment cessation, reductions of the prolonged QTc and QRS intervals were sustained in Bz-plus-PTX-treated mice. Our findings support the importance of interfering with the etiological agent and immunological abnormalities to improve CCC prognosis, opening an opportunity for a better quality of life for Chagas' disease (CD) patients. PMID:27161638

  4. 2. Photocopied July 1971 from photostat Jordan Narrows Folder #1, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Photocopied July 1971 from photostat Jordan Narrows Folder #1, Engineering Department, Utah Power and Light Co., Salt Lake City, Utah. JORDAN NARROWS STATION. PLAN AND SECTION. - Salt Lake City Water & Electrical Power Company, Jordan Narrows Hydroelectric Plant, Jordan River, Riverton, Salt Lake County, UT

  5. Bicarbonate refractory QRS prolongation and left bundle-branch block following escitalopram and lamotrigine overdose: A case report and literature review of toxic left bundle-branch block.

    PubMed

    Farkas, A N; Marcott, M; Yanta, J H; Pizon, A F

    2018-05-02

    Toxic prolongation of the QRS interval most often results from blockade of cardiac voltage-gated sodium channels and manifests on electrocardiogram with a right bundle-branch block-like morphology. Rarely, a left bundle-branch block (LBBB) morphology has been reported. We report a case of transient LBBB resultant from ingestion of lamotrigine and citalopram which was refractory to sodium bicarbonate therapy and eventually resolved spontaneously. Cases of toxic LBBB are less likely to respond to bicarbonate therapy, suggesting that this finding is due to a mechanism other than sodium channel blockade. © 2018 John Wiley & Sons Ltd.

  6. An enhanced narrow-band imaging method for the microvessel detection

    NASA Astrophysics Data System (ADS)

    Yu, Feng; Song, Enmin; Liu, Hong; Wan, Youming; Zhu, Jun; Hung, Chih-Cheng

    2018-02-01

    A medical endoscope system combined with the narrow-band imaging (NBI), has been shown to be a superior diagnostic tool for early cancer detection. The NBI can reveal the morphologic changes of microvessels in the superficial cancer. In order to improve the conspicuousness of microvessel texture, we propose an enhanced NBI method to improve the conspicuousness of endoscopic images. To obtain the more conspicuous narrow-band images, we use the edge operator to extract the edge information of the narrow-band blue and green images, and give a weight to the extracted edges. Then, the weighted edges are fused with the narrow-band blue and green images. Finally, the displayed endoscopic images are reconstructed with the enhanced narrow-band images. In addition, we evaluate the performance of enhanced narrow-band images with different edge operators. Experimental results indicate that the Sobel and Canny operators achieve the best performance of all. Compared with traditional NBI method of Olympus company, our proposed method has more conspicuous texture of microvessel.

  7. Acquisition and visualization techniques for narrow spectral color imaging.

    PubMed

    Neumann, László; García, Rafael; Basa, János; Hegedüs, Ramón

    2013-06-01

    This paper introduces a new approach in narrow-band imaging (NBI). Existing NBI techniques generate images by selecting discrete bands over the full visible spectrum or an even wider spectral range. In contrast, here we perform the sampling with filters covering a tight spectral window. This image acquisition method, named narrow spectral imaging, can be particularly useful when optical information is only available within a narrow spectral window, such as in the case of deep-water transmittance, which constitutes the principal motivation of this work. In this study we demonstrate the potential of the proposed photographic technique on nonunderwater scenes recorded under controlled conditions. To this end three multilayer narrow bandpass filters were employed, which transmit at 440, 456, and 470 nm bluish wavelengths, respectively. Since the differences among the images captured in such a narrow spectral window can be extremely small, both image acquisition and visualization require a novel approach. First, high-bit-depth images were acquired with multilayer narrow-band filters either placed in front of the illumination or mounted on the camera lens. Second, a color-mapping method is proposed, using which the input data can be transformed onto the entire display color gamut with a continuous and perceptually nearly uniform mapping, while ensuring optimally high information content for human perception.

  8. Differentiating the origin of outflow tract ventricular arrhythmia using a simple, novel approach.

    PubMed

    Efimova, Elena; Dinov, Borislav; Acou, Willem-Jan; Schirripa, Valentina; Kornej, Jelena; Kosiuk, Jedrzej; Rolf, Sascha; Sommer, Philipp; Richter, Sergio; Bollmann, Andreas; Hindricks, Gerhard; Arya, Arash

    2015-07-01

    Numerous electrocardiographic (ECG) criteria have been proposed to identify localization of outflow tract ventricular arrhythmias (OT-VAs); however, in some cases, it is difficult to accurately localize the origin of OT-VA using the surface ECG. The purpose of this study was to assess a simple criterion for localization of OT-VAs during electrophysiology study. We measured the interval from the onset of the earliest QRS complex of premature ventricular contractions (PVCs) to the distal right ventricular apical signal (the QRS-RVA interval) in 66 patients (31 men aged 53.3 ± 14.0 years; right ventricular outflow tract [RVOT] origin in 37) referred for ablation of symptomatic outflow tract PVCs. We prospectively validated this criterion in 39 patients (22 men aged 52 ± 15 years; RVOT origin in 19). Compared with patients with RVOT PVCs, the QRS-RVA interval was significantly longer in patients with left ventricular outflow tract (LVOT) PVCs (70 ± 14 vs 33.4±10 ms, P < .001). Receiver operating characteristic analysis showed that a QRS-RVA interval ≥49 ms had sensitivity, specificity, and positive and negative predictive values of 100%, 94.6%, 93.5%, and 100%, respectively, for prediction of an LVOT origin. The same analysis in the validation cohort showed sensitivity, specificity, and positive and negative predictive values of 94.7%, 95%, 95%, and 94.7%, respectively. When these data were combined, a QRS-RVA interval ≥49 ms had sensitivity, specificity, and positive and negative predictive values of 98%, 94.6%, 94.1%, and 98.1%, respectively, for prediction of an LVOT origin. A QRS-RVA interval ≥49 ms suggests an LVOT origin. The QRS-RVA interval is a simple and accurate criterion for differentiating the origin of outflow tract arrhythmia during electrophysiology study; however, the accuracy of this criterion in identifying OT-VA from the right coronary cusp is limited. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  9. Patients with left bundle branch block and left axis deviation show a specific left ventricular asynchrony pattern: Implications for left ventricular lead placement during CRT implantation.

    PubMed

    Sciarra, Luigi; Golia, Paolo; Palamà, Zefferino; Scarà, Antonio; De Ruvo, Ermenegildo; Borrelli, Alessio; Martino, Anna Maria; Minati, Monia; Fagagnini, Alessandro; Tota, Claudia; De Luca, Lucia; Grieco, Domenico; Delise, Pietro; Calò, Leonardo

    Left bundle branch block (LBBB) and left axis deviation (LAD) patients may have poor response to resynchronization therapy (CRT). We sought to assess if LBBB and LAD patients show a specific pattern of mechanical asynchrony. CRT candidates with non-ischemic cardiomyopathy and LBBB were categorized as having normal QRS axis (within -30° and +90°) or LAD (within -30° and -90°). Patients underwent tissue Doppler imaging (TDI) to measure time interval between onset of QRS complex and peak systolic velocity in ejection period (Q-peak) at basal segments of septal, inferior, lateral and anterior walls, as expression of local timing of mechanical activation. Thirty patients (mean age 70.6years; 19 males) were included. Mean left ventricular ejection fraction was 0.28±0.06. Mean QRS duration was 172.5±13.9ms. Fifteen patients showed LBBB with LAD (QRS duration 173±14; EF 0.27±0.06). The other 15 patients had LBBB with a normal QRS axis (QRS duration 172±14; EF 0.29±0.05). Among patients with LAD, Q-peak interval was significantly longer at the anterior wall in comparison to each other walls (septal 201±46ms, inferior 242±58ms, lateral 267±45ms, anterior 302±50ms; p<0.0001). Conversely, in patients without LAD Q-peak interval was longer at lateral wall, when compared to each other (septal 228±65ms, inferior 250±64ms, lateral 328±98ms, anterior 291±86ms; p<0.0001). Patients with heart failure, presenting LBBB and LAD, show a specific pattern of ventricular asynchrony, with latest activation at anterior wall. This finding could affect target vessel selection during CRT procedures in these patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Right precordial-directed electrocardiographical markers identify arrhythmogenic right ventricular cardiomyopathy in the absence of conventional depolarization or repolarization abnormalities.

    PubMed

    Cortez, Daniel; Svensson, Anneli; Carlson, Jonas; Graw, Sharon; Sharma, Nandita; Brun, Francesca; Spezzacatene, Anita; Mestroni, Luisa; Platonov, Pyotr G

    2017-10-13

    Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) carries a risk of sudden death. We aimed to assess whether vectorcardiographic (VCG) parameters directed toward the right heart and a measured angle of the S-wave would help differentiate ARVD/C with otherwise normal electrocardiograms from controls. Task Force 2010 definite ARVD/C criteria were met for all patients. Those who did not fulfill Task Force depolarization or repolarization criteria (-ECG) were compared with age and gender-matched control subjects. Electrocardiogram measures of a 3-dimentional spatial QRS-T angle, a right-precordial-directed orthogonal QRS-T (RPD) angle, a root mean square of the right sided depolarizing forces (RtRMS-QRS), QRS duration (QRSd) and the corrected QT interval (QTc), and a measured angle including the upslope and downslope of the S-wave (S-wave angle) were assessed. Definite ARVD/C was present in 155 patients by 2010 Task Force criteria (41.7 ± 17.6 years, 65.2% male). -ECG ARVD/C patients (66 patients) were compared to 66 control patients (41.7 ± 17.6 years, 65.2% male). All parameters tested except the QRSd and QTc significantly differentiated -ECG ARVD/C from control patients (p < 0.004 to p < 0.001). The RPD angle and RtRMS-QRS best differentiated the groups. Combined, the 2 novel criteria gave 81.8% sensitivity, 90.9% specificity and odds ratio of 45.0 (95% confidence interval 15.8 to 128.2). ARVD/C disease process may lead to development of subtle ECG abnormalities that can be distinguishable using right-sided VCG or measured angle markers better than the spatial QRS-T angle, the QRSd or QTc, in the absence of Taskforce ECG criteria.

  11. Associations between narrow angle and adult anthropometry: the Liwan Eye Study.

    PubMed

    Jiang, Yuzhen; He, Mingguang; Friedman, David S; Khawaja, Anthony P; Lee, Pak Sang; Nolan, Winifred P; Yin, Qiuxia; Foster, Paul J

    2014-06-01

    To assess the associations between narrow angle and adult anthropometry. Chinese adults aged 50 years and older were recruited from a population-based survey in the Liwan District of Guangzhou, China. Narrow angle was defined as the posterior trabecular meshwork not visible under static gonioscopy in at least three quadrants (i.e. a circumference of at least 270°). Logistic regression models were used to examine the associations between narrow angle and anthropomorphic measures (height, weight and body mass index, BMI). Among the 912 participants, lower weight, shorter height, and lower BMI were significantly associated with narrower angle width (tests for trend: mean angle width in degrees vs weight p < 0.001; vs height p < 0.001; vs BMI p = 0.012). In univariate analyses, shorter height, lower weight and lower BMI were all significantly associated with greater odds of narrow angle. The crude association between height and narrow angle was largely attributable to a stronger association with age and sex. Lower BMI and weight remained significantly associated with narrow angle after adjustment for height, age, sex, axial ocular biometric measures and education. In analyses stratified by sex, the association between BMI and narrow angle was only observed in women. Lower BMI and weight were associated with significantly greater odds of narrow angle after adjusting for age, education, axial ocular biometric measures and height. The odds of narrow angle increased 7% per 1 unit decrease in BMI. This association was most evident in women.

  12. Hot Wax Sweeps Debris From Narrow Passages

    NASA Technical Reports Server (NTRS)

    Ricklefs, Steven K.

    1990-01-01

    Safe and effective technique for removal of debris and contaminants from narrow passages involves entrainment of undesired material in thermoplastic casting material. Semisolid wax slightly below melting temperature pushed along passage by pressurized nitrogen to remove debris. Devised to clean out fuel passages in main combustion chamber of Space Shuttle main engine. Also applied to narrow, intricate passages in internal-combustion-engine blocks, carburetors, injection molds, and other complicated parts.

  13. Diabetes Mellitus and Outcomes of Cardiac Resynchronization With Implantable Cardioverter-Defibrillator Therapy in Older Patients With Heart Failure.

    PubMed

    Echouffo-Tcheugui, Justin B; Masoudi, Frederick A; Bao, Haikun; Spatz, Erica S; Fonarow, Gregg C

    2016-08-01

    Large-scale data on outcomes with cardiac resynchronization therapy with defibrillator in patients with diabetes mellitus are limited. We compared outcomes after cardiac resynchronization therapy with defibrillator implantation among patients with heart failure who have diabetes mellitus versus those without diabetes mellitus. Survival curves and covariate adjusted hazard ratio (HR) or odds ratio were used to assess the risks for death, readmission, and device-related complications by diabetes mellitus status among 18 428 patients at least 65 years old receiving cardiac resynchronization therapy with defibrillator from the National Cardiovascular Data Registry, implantable cardioverter-defibrillator registry between 2006 and 2009, with up to 3 years of follow-up. Accounting for differences between groups, compared with those without diabetes mellitus (n=11 345), patients with diabetes mellitus (n=7083) had a higher risk of death both at 1 year (HR, 1.16 [95% confidence interval (CI), 1.05-1.29]; P=0.0037) and 3 years (HR, 1.21 [1.14-1.29]; P<0.001) after device implantation and higher risks of all-cause readmission (sub-HR, 1.16 [1.11-1.21] at 1 year; P<0.0001; sub-HR, 1.15 [1.11-1.19] at 3 years; P<0.0001) and heart failure-related readmission (sub-HR, 1.18 [1.09-1.28] at 1 year; P<0.0001; and sub-HR, 1.22 [1.15-1.30] at 3 years; P<0.0001). Device-related complications within 90 days did not differ between those with and without diabetes mellitus (odds ratio: 0.90 [0.77-1.06]; P=0.37). Interactions of age, sex, ischemic cardiomyopathy, renal failure, or QRS duration were not significant. In older patients with heart failure receiving cardiac resynchronization therapy with defibrillator, diabetes mellitus was independently associated with greater risks of death and rehospitalization, but similar risks of procedural complications. © 2016 American Heart Association, Inc.

  14. Electrocardiogram reference intervals for clinically normal wild-born chimpanzees (Pan troglodytes).

    PubMed

    Atencia, Rebeca; Revuelta, Luis; Somauroo, John D; Shave, Robert E

    2015-08-01

    To generate reference intervals for ECG variables in clinically normal chimpanzees (Pan troglodytes). 100 clinically normal (51 young [< 10 years old] and 49 adult [≥ 10 years old]) wild-born chimpanzees. Electrocardiograms collected between 2009 and 2013 at the Tchimpounga Chimpanzee Rehabilitation Centre were assessed to determine heart rate, PR interval, QRS duration, QT interval, QRS axis, P axis, and T axis. Electrocardiographic characteristics for left ventricular hypertrophy (LVH) and morphology of the ST segment, T wave, and QRS complex were identified. Reference intervals for young and old animals were calculated as mean ± 1.96•SD for normally distributed data and as 5th to 95th percentiles for data not normally distributed. Differences between age groups were assessed by use of unpaired Student t tests. RESULTS Reference intervals were generated for young and adult wild-born chimpanzees. Most animals had sinus rhythm with small or normal P wave morphology; 24 of 51 (47%) young chimpanzees and 30 of 49 (61%) adult chimpanzees had evidence of LVH as determined on the basis of criteria for humans. Cardiac disease has been implicated as the major cause of death in captive chimpanzees. Species-specific ECG reference intervals for chimpanzees may aid in the diagnosis and treatment of animals with, or at risk of developing, heart disease. Chimpanzees with ECG characteristics outside of these intervals should be considered for follow-up assessment and regular cardiac monitoring.

  15. Fracture strength and probability of survival of narrow and extra-narrow dental implants after fatigue testing: In vitro and in silico analysis.

    PubMed

    Bordin, Dimorvan; Bergamo, Edmara T P; Fardin, Vinicius P; Coelho, Paulo G; Bonfante, Estevam A

    2017-07-01

    To assess the probability of survival (reliability) and failure modes of narrow implants with different diameters. For fatigue testing, 42 implants with the same macrogeometry and internal conical connection were divided, according to diameter, as follows: narrow (Ø3.3×10mm) and extra-narrow (Ø2.9×10mm) (21 per group). Identical abutments were torqued to the implants and standardized maxillary incisor crowns were cemented and subjected to step-stress accelerated life testing (SSALT) in water. The use-level probability Weibull curves, and reliability for a mission of 50,000 and 100,000 cycles at 50N, 100, 150 and 180N were calculated. For the finite element analysis (FEA), two virtual models, simulating the samples tested in fatigue, were constructed. Loading at 50N and 100N were applied 30° off-axis at the crown. The von-Mises stress was calculated for implant and abutment. The beta (β) values were: 0.67 for narrow and 1.32 for extra-narrow implants, indicating that failure rates did not increase with fatigue in the former, but more likely were associated with damage accumulation and wear-out failures in the latter. Both groups showed high reliability (up to 97.5%) at 50 and 100N. A decreased reliability was observed for both groups at 150 and 180N (ranging from 0 to 82.3%), but no significant difference was observed between groups. Failure predominantly involved abutment fracture for both groups. FEA at 50N-load, Ø3.3mm showed higher von-Mises stress for abutment (7.75%) and implant (2%) when compared to the Ø2.9mm. There was no significant difference between narrow and extra-narrow implants regarding probability of survival. The failure mode was similar for both groups, restricted to abutment fracture. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Associations between Narrow Angle and Adult Anthropometry: The Liwan Eye Study

    PubMed Central

    Jiang, Yuzhen; He, Mingguang; Friedman, David S.; Khawaja, Anthony P.; Lee, Pak Sang; Nolan, Winifred P.; Yin, Qiuxia; Foster, Paul J.

    2015-01-01

    Purpose To assess the associations between narrow angle and adult anthropometry. Methods Chinese adults aged 50 years and older were recruited from a population-based survey in the Liwan District of Guangzhou, China. Narrow angle was defined as the posterior trabecular meshwork not visible under static gonioscopy in at least three quadrants (i.e. a circumference of at least 270°). Logistic regression models were used to examine the associations between narrow angle and anthropomorphic measures (height, weight and body mass index, BMI). Results Among the 912 participants, lower weight, shorter height, and lower BMI were significantly associated with narrower angle width (tests for trend: mean angle width in degrees vs weight p<0.001; vs height p<0.001; vs BMI p = 0.012). In univariate analyses, shorter height, lower weight and lower BMI were all significantly associated with greater odds of narrow angle. The crude association between height and narrow angle was largely attributable to a stronger association with age and sex. Lower BMI and weight remained significantly associated with narrow angle after adjustment for height, age, sex, axial ocular biometric measures and education. In analyses stratified by sex, the association between BMI and narrow angle was only observed in women. Conclusion Lower BMI and weight were associated with significantly greater odds of narrow angle after adjusting for age, education, axial ocular biometric measures and height. The odds of narrow angle increased 7% per 1 unit decrease in BMI. This association was most evident in women. PMID:24707840

  17. Regulatory systems for hypoxia-inducible gene expression in ischemic heart disease gene therapy.

    PubMed

    Kim, Hyun Ah; Rhim, Taiyoun; Lee, Minhyung

    2011-07-18

    Ischemic heart diseases are caused by narrowed coronary arteries that decrease the blood supply to the myocardium. In the ischemic myocardium, hypoxia-responsive genes are up-regulated by hypoxia-inducible factor-1 (HIF-1). Gene therapy for ischemic heart diseases uses genes encoding angiogenic growth factors and anti-apoptotic proteins as therapeutic genes. These genes increase blood supply into the myocardium by angiogenesis and protect cardiomyocytes from cell death. However, non-specific expression of these genes in normal tissues may be harmful, since growth factors and anti-apoptotic proteins may induce tumor growth. Therefore, tight gene regulation is required to limit gene expression to ischemic tissues, to avoid unwanted side effects. For this purpose, various gene expression strategies have been developed for ischemic-specific gene expression. Transcriptional, post-transcriptional, and post-translational regulatory strategies have been developed and evaluated in ischemic heart disease animal models. The regulatory systems can limit therapeutic gene expression to ischemic tissues and increase the efficiency of gene therapy. In this review, recent progresses in ischemic-specific gene expression systems are presented, and their applications to ischemic heart diseases are discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Ultra-thin narrow-band, complementary narrow-band, and dual-band metamaterial absorbers for applications in the THz regime

    NASA Astrophysics Data System (ADS)

    Astorino, Maria Denise; Frezza, Fabrizio; Tedeschi, Nicola

    2017-02-01

    In this paper, ultra-thin narrow-band, complementary narrow-band, and dual-band metamaterial absorbers (MMAs), exploiting the same electric ring resonator configuration, are investigated at normal and oblique incidence for both transverse electric (TE) and transverse magnetic (TM) polarizations, and with different physical properties in the THz regime. In the analysis of the ultra-thin narrow-band MMA, the limit of applicability of the transmission line model has been overcome with the introduction of a capacitance which considers the z component of the electric field. These absorbing structures have shown a wide angular response and a polarization-insensitive behavior due to the introduction of a conducting ground plane and to the four-fold rotational symmetry of the resonant elements around the propagation axis. We have adopted a retrieval procedure to extract the effective electromagnetic parameters of the proposed MMAs and we have compared the simulated and analytical results through the interference theory.

  19. Narrow-band generation in random distributed feedback fiber laser.

    PubMed

    Sugavanam, Srikanth; Tarasov, Nikita; Shu, Xuewen; Churkin, Dmitry V

    2013-07-15

    Narrow-band emission of spectral width down to ~0.05 nm line-width is achieved in the random distributed feedback fiber laser employing narrow-band fiber Bragg grating or fiber Fabry-Perot interferometer filters. The observed line-width is ~10 times less than line-width of other demonstrated up to date random distributed feedback fiber lasers. The random DFB laser with Fabry-Perot interferometer filter provides simultaneously multi-wavelength and narrow-band (within each line) generation with possibility of further wavelength tuning.

  20. Late deterioration of left ventricular function after right ventricular pacemaker implantation.

    PubMed

    Bellmann, Barbara; Muntean, Bogdan G; Lin, Tina; Gemein, Christopher; Schmitz, Kathrin; Schauerte, Patrick

    2016-09-01

    Right ventricular (RV) pacing induces a left bundle branch block pattern on ECG and may promote heart failure. Patients with dual chamber pacemakers (DCPs) who present with progressive reduction in left ventricular ejection fraction (LVEF) secondary to RV pacing are candidates for cardiac resynchronization therapy (CRT). This study analyzes whether upgrading DCP to CRT with the additional implantation of a left ventricular (LV) lead improves LV function in patients with reduced LVEF following DCP implantation. Twenty-two patients (13 males) implanted with DCPs and a high RV pacing percentage (>90%) were evaluated in term of new-onset heart failure symptoms. The patients were enrolled in this retrospective single-center study after obvious causes for a reduced LVEF were excluded with echocardiography and coronary angiography. In all patients, DCPs were then upgraded to biventricular devices. LVEF was analyzed with a two-sided t-test. QRS duration and brain natriuretic peptide (BNP) levels were analyzed with the unpaired t-test. LVEF declined after DCP implantation from 54±10% to 31±7%, and the mean QRS duration was 161±20 ms during RV pacing. NT-pro BNP levels were elevated (3365±11436 pmol/L). After upgrading to a biventricular device, a biventricular pacing percentage of 98.1±2% was achieved. QRS duration decreased to 108±16 ms and 106±20 ms after 1 and 6 months, respectively. There was a significant increase in LVEF to 38±8% and 41±11% and a decrease in NT-pro BNP levels to 3088±2326 pmol/L and 1860±1838 pmol/L at 1 and 6 months, respectively. Upgrading to CRT may be beneficial in patients with DCPs and heart failure induced by a high RV pacing percentage.

  1. Consequences of narrow cyclotron emission from Hercules X-1

    NASA Technical Reports Server (NTRS)

    Weaver, R. P.

    1978-01-01

    The implications of the recent observations of a narrow cyclotron line in the hard X-ray spectrum of Hercules X-1 are studied. A Monte Carlo code is used to simulate the X-ray transfer of an intrinsically narrow feature at approximately 56 keV through an opaque, cold magnetospheric shell. The results of this study indicate that if a narrow line can be emitted by the source region, then only about 10% of the photons remain in a narrow feature after scattering through the shell. The remaining photons are scattered into a broad feature (FWHM approximately 30 keV) that peaks near 20 keV. Thus, these calculations indicate that the intrinsic source luminosity of the cyclotron line is at least an order of magnitude greater than the observed luminosity.

  2. Design, Construction, Demonstration and Delivery of an Automated Narrow Gap Welding System.

    DTIC Science & Technology

    1982-06-29

    DESIGN, CONSTRUCTION, DEMONSTRATION AND DELIVERY OF WE DA4I &NARROW GAP CONTRACT NO. NOOGOO-81-C-E923 TO DAVID TAYLOR NAVAL RESEARCH AND DEVELOPMENT...the automated * Narrow Gap welding process, is the narrow (3/8 - inch), square-butt joint *design. This narrow joint greatly reduces the volume of weld...AD-i45 495 DESIGN CONSTRUCTION DEMONSTRATION AiND DELIVERY OF RN 1/j AUrOMATED NARROW GAP WELDING SYSTEMI() CRC AUTOMATIC WELDING CO HOUSTON TX 29

  3. Bayesian Face Recognition and Perceptual Narrowing in Face-Space

    PubMed Central

    Balas, Benjamin

    2012-01-01

    During the first year of life, infants’ face recognition abilities are subject to “perceptual narrowing,” the end result of which is that observers lose the ability to distinguish previously discriminable faces (e.g. other-race faces) from one another. Perceptual narrowing has been reported for faces of different species and different races, in developing humans and primates. Though the phenomenon is highly robust and replicable, there have been few efforts to model the emergence of perceptual narrowing as a function of the accumulation of experience with faces during infancy. The goal of the current study is to examine how perceptual narrowing might manifest as statistical estimation in “face space,” a geometric framework for describing face recognition that has been successfully applied to adult face perception. Here, I use a computer vision algorithm for Bayesian face recognition to study how the acquisition of experience in face space and the presence of race categories affect performance for own and other-race faces. Perceptual narrowing follows from the establishment of distinct race categories, suggesting that the acquisition of category boundaries for race is a key computational mechanism in developing face expertise. PMID:22709406

  4. Narrow Escape of Interacting Diffusing Particles

    NASA Astrophysics Data System (ADS)

    Agranov, Tal; Meerson, Baruch

    2018-03-01

    The narrow escape problem deals with the calculation of the mean escape time (MET) of a Brownian particle from a bounded domain through a small hole on the domain's boundary. Here we develop a formalism which allows us to evaluate the nonescape probability of a gas of diffusing particles that may interact with each other. In some cases the nonescape probability allows us to evaluate the MET of the first particle. The formalism is based on the fluctuating hydrodynamics and the recently developed macroscopic fluctuation theory. We also uncover an unexpected connection between the narrow escape of interacting particles and thermal runaway in chemical reactors.

  5. Heart Health - Brave Heart

    MedlinePlus

    ... Bar Home Current Issue Past Issues Cover Story Heart Health Brave Heart Past Issues / Winter 2009 Table of Contents For ... you can have a good life after a heart attack." Lifestyle Changes Surviving—and thriving—after such ...

  6. Parametric Dynamic Load Prediction of a Narrow Gauge Rocket Sled

    DTIC Science & Technology

    2006-12-01

    Monorail λ Compared to Sled Tests.......................................................... 11 Figure 2.1 Application of Vertical λ to a Narrow Gauge sled...Three distinct sled configurations are used: monorail , dual rail wide gauge, and dual rail narrow gauge. Of the three, the narrow gauge...weight and the resulting value was termed λ. Monorail λ factor loading was first documented by Mixon (1971) where a few measured data points were

  7. Pulse stretcher for narrow pulses

    NASA Technical Reports Server (NTRS)

    Lindsey, R. S., Jr. (Inventor)

    1974-01-01

    A pulse stretcher for narrow pulses is presented. The stretcher is composed of an analog section for processing each arriving analog pulse and a digital section with logic for providing command signals to the gates and switches in the analog section.

  8. Studies on deflection area vectors of QRS and T and ventricular gradient in right ventricular hypertrophy.

    PubMed

    Kawaguchi, Y

    1985-04-01

    QRS deflection area vector (Aqrs), T deflection area vector (At) and ventricular gradient (G) in right ventricular hypertrophy were studied in 53 subjects divided on the basis of cardiac catheterization data into four subgroups; normal controls, mild MS group, right ventricular pressure overload group and right ventricular volume overload group. Aqrs, At and G of the four subgroups were calculated using a microcomputer and compared. Aqrs in right ventricular pressure overload group and volume overload group was shifted to the right and slightly anteriorly from that in normal control group. At in right ventricular pressure overload group and volume overload group was shifted slightly upwards and significantly posteriorly from that in the normal control and mild MS groups. G in right ventricular pressure overload group and volume overload group was shifted to the right and significantly posteriorly from that in normal control and mild MS groups. Using multivariative analysis, we developed criteria for diagnosing right ventricular hypertrophy with At: 0.059At(Z) - 0.0145 [At] - 0.2608 less than or equal to 0. Application of this criteria achieved 82.4% (28 of 34) sensitivity in the patients with right ventricular hypertrophy and 90.9% (10 of 11) specificity in the normal control subjects.

  9. New echocardiographic predictors of clinical outcome in patients presenting with heart failure and a preserved left ventricular ejection fraction: a subanalysis of the Ka (Karolinska) Ren (Rennes) Study.

    PubMed

    Donal, Erwan; Lund, Lars H; Oger, Emmanuel; Hage, Camilla; Persson, Hans; Reynaud, Amélie; Ennezat, Pierre-Vladimir; Bauer, Fabrice; Drouet, Elodie; Linde, Cecilia; Daubert, Claude

    2015-07-01

    To identify electrocardiographic and echocardiographic predictors of mortality and hospitalizations for heart failure (HF) in the KaRen study. KaRen is a prospective, observational study of the long-term outcomes of patients presenting with heart failure and a preserved ejection fraction (HFpEF). We identified 538 patients who presented with acute cardiac decompensation, a >100 pg/mL serum b-type natriuretic peptide (BNP) or >300 pg/mL N-terminal pro-brain natriuretic peptide (NT-proBNP) concentration and a left ventricular ejection fraction (LVEF) >45%. After 4-8 weeks of standard treatment, 413 patients (mean age = 76 ± 9 years, 55.9% women) returned for analyses of their clinical status, laboratory screen, and detailed electrocardiographic and Doppler echocardiographic recordings. They were followed for a mean of 28 months thereafter. The primary study endpoint was time to death from all causes or first hospitalization for heart failure. Mean LVEF was 62.4 ± 6.9% and median NT-proBNP 1410 pmol/L. PR interval >200 ms was present in 11.2% of patients and 14.9% had a >120 ms QRS duration, with left bundle branch block in only 6.3%. Over a mean follow-up of 28 months, 177 patients (42.9%) reached a primary study endpoint, including 61 deaths and 116 hospitalizations for heart failure. After adjustment for age, gender, New York Heart Association class, atrial fibrillation history, creatinine, sodium, BNP, ejection fraction, and right ventricular fractional shortening, only E/e' remained as a predictor, with a hazard ratio = 1.49 and P = 0.0012. The incidence of hospitalizations for HF and deaths in KaRen was high and E/e' predicted adverse clinical outcomes. These observations should help in the risk stratification and therapy of HFpEF. © 2015 The Authors. European Journal of Heart Failure © 2015 European Society of Cardiology.

  10. The narrow pentaquark

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diakonov, Dmitri

    2007-02-27

    The experimental status of the pentaquark searches is briefly reviewed. Recent null results by the CLAS collaboration are commented, and new strong evidence of a very narrow {theta}+ resonance by the DIANA collaboration is presented. On the theory side, I revisit the argument against the existence of the pentaquark - that of Callan and Klebanov - and show that actually a strong resonance is predicted in that approach, however its width is grossly overestimated. A recent calculation gives 2 MeV for the pentaquark width, and this number is probably still an upper bound.

  11. Electrocardiographic Characterization of Cardiac Hypertrophy in Mice that Overexpress the ErbB2 Receptor Tyrosine Kinase

    PubMed Central

    Sysa-Shah, Polina; Sørensen, Lars L; Abraham, M Roselle; Gabrielson, Kathleen L

    2015-01-01

    Electrocardiography is an important method for evaluation and risk stratification of patients with cardiac hypertrophy. We hypothesized that the recently developed transgenic mouse model of cardiac hypertrophy (ErbB2tg) will display distinct ECG features, enabling WT (wild type) mice to be distinguished from transgenic mice without using conventional PCR genotyping. We evaluated more than 2000 mice and developed specific criteria for genotype determination by using cageside ECG, during which unanesthetized mice were manually restrained for less than 1 min. Compared with those from WT counterparts, the ECG recordings of ErbB2tg mice were characterized by higher P- and R-wave amplitudes, broader QRS complexes, inverted T waves, and ST interval depression. Pearson's correlation matrix analysis of combined WT and ErbB2tg data revealed significant correlation between heart weight and the ECG parameters of QT interval (corrected for heart rate), QRS interval, ST height, R amplitude, P amplitude, and PR interval. In addition, the left ventricular posterior wall thickness as determined by echocardiography correlated with ECG-determined ST height, R amplitude, QRS interval; echocardiographic left ventricular mass correlated with ECG-determined ST height and PR interval. In summary, we have determined phenotypic ECG criteria to differentiate ErbB2tg from WT genotypes in 98.8% of mice. This inexpensive and time-efficient ECG-based phenotypic method might be applied to differentiate between genotypes in other rodent models of cardiac hypertrophy. Furthermore, with appropriate modifications, this method might be translated for use in other species. PMID:26310459

  12. Galaxy properties from J-PAS narrow-band photometry

    NASA Astrophysics Data System (ADS)

    Mejía-Narváez, A.; Bruzual, G.; Magris, C. G.; Alcaniz, J. S.; Benítez, N.; Carneiro, S.; Cenarro, A. J.; Cristóbal-Hornillos, D.; Dupke, R.; Ederoclite, A.; Marín-Franch, A.; de Oliveira, C. Mendes; Moles, M.; Sodre, L.; Taylor, K.; Varela, J.; Ramió, H. Vázquez

    2017-11-01

    We study the consistency of the physical properties of galaxies retrieved from spectral energy distribution (SED) fitting as a function of spectral resolution and signal-to-noise ratio (SNR). Using a selection of physically motivated star formation histories, we set up a control sample of mock galaxy spectra representing observations of the local Universe in high-resolution spectroscopy, and in 56 narrow-band and 5 broad-band photometry. We fit the SEDs at these spectral resolutions and compute their corresponding stellar mass, the mass- and luminosity-weighted age and metallicity, and the dust extinction. We study the biases, correlations and degeneracies affecting the retrieved parameters and explore the role of the spectral resolution and the SNR in regulating these degeneracies. We find that narrow-band photometry and spectroscopy yield similar trends in the physical properties derived, the former being considerably more precise. Using a galaxy sample from the Sloan Digital Sky Survey (SDSS), we compare more realistically the results obtained from high-resolution and narrow-band SEDs (synthesized from the same SDSS spectra) following the same spectral fitting procedures. We use results from the literature as a benchmark to our spectroscopic estimates and show that the prior probability distribution functions, commonly adopted in parametric methods, may introduce biases not accounted for in a Bayesian framework. We conclude that narrow-band photometry yields the same trend in the age-metallicity relation in the literature, provided it is affected by the same biases as spectroscopy, albeit the precision achieved with the latter is generally twice as large as with the narrow-band, at SNR values typical of the different kinds of data.

  13. The Effect of Divided Attention on Emotion-Induced Memory Narrowing

    PubMed Central

    Steinmetz, Katherine R. Mickley; Waring, Jill D.; Kensinger, Elizabeth A.

    2014-01-01

    Individuals are more likely to remember emotional than neutral information, but this benefit does not always extend to the surrounding background information. This memory narrowing is theorized to be linked to the availability of attentional resources at encoding. In contrast to the predictions of this theoretical account, altering participants’ attentional resources at encoding, by dividing attention, did not affect the emotion-induced memory narrowing. Attention was divided using three separate manipulations: a digit ordering task (Experiment 1), an arithmetic task (Experiment 2), and an auditory discrimination task (Experiment 3). Across all three experiments, divided attention decreased memory across-the-board but did not affect the degree of memory narrowing. These findings suggest that theories to explain memory narrowing must be expanded to include other potential mechanisms beyond limitations of attentional resources. PMID:24295041

  14. The effect of divided attention on emotion-induced memory narrowing.

    PubMed

    Mickley Steinmetz, Katherine R; Waring, Jill D; Kensinger, Elizabeth A

    2014-01-01

    Individuals are more likely to remember emotional than neutral information, but this benefit does not always extend to the surrounding background information. This memory narrowing is theorised to be linked to the availability of attentional resources at encoding. In contrast to the predictions of this theoretical account, altering participants' attentional resources at encoding by dividing attention did not affect emotion-induced memory narrowing. Attention was divided using three separate manipulations: a digit ordering task (Experiment 1), an arithmetic task (Experiment 2) and an auditory discrimination task (Experiment 3). Across all three experiments, divided attention decreased memory across the board but did not affect the degree of memory narrowing. These findings suggest that theories to explain memory narrowing must be expanded to include other potential mechanisms beyond the limitations of attentional resources.

  15. Bayesian Face Recognition and Perceptual Narrowing in Face-Space

    ERIC Educational Resources Information Center

    Balas, Benjamin

    2012-01-01

    During the first year of life, infants' face recognition abilities are subject to "perceptual narrowing", the end result of which is that observers lose the ability to distinguish previously discriminable faces (e.g. other-race faces) from one another. Perceptual narrowing has been reported for faces of different species and different races, in…

  16. Very narrow excited Ωc baryons

    NASA Astrophysics Data System (ADS)

    Karliner, Marek; Rosner, Jonathan L.

    2017-06-01

    Recently, LHCb reported the discovery of five extremely narrow excited Ωc baryons decaying into Ξc+K-. We interpret these baryons as bound states of a c quark and a P -wave s s diquark. For such a system, there are exactly five possible combinations of spin and orbital angular momentum. The narrowness of the states could be a signal that it is hard to pull apart the two s quarks in a diquark. We predict two of spin 1 /2 , two of spin 3 /2 , and one of spin 5 /2 , all with negative parity. Of the five states, two can decay in S -wave, and three can decay in D -wave. Some of the D -wave states might be narrower than the S -wave states. We discuss the relations among the five masses expected in the quark model and the likely spin assignments, and we compare them with the data. A similar pattern is expected for negative-parity excited Ωb states. An alternative interpretation is noted in which the heaviest two states are 2 S excitations with JP=1 /2+ and 3 /2+, while the lightest three are those with JP=3 /2- , 3 /2- , 5 /2- , expected to decay via D -waves. In this case, we expect JP=1 /2- Ωc states around 2904 and 2978 MeV.

  17. The total right/left-volume index: a new and simplified cardiac magnetic resonance measure to evaluate the severity of Ebstein anomaly of the tricuspid valve: a comparison with heart failure markers from various modalities.

    PubMed

    Hösch, Olga; Sohns, Jan Martin; Nguyen, Thuy-Trang; Lauerer, Peter; Rosenberg, Christina; Kowallick, Johannes Tammo; Kutty, Shelby; Unterberg, Christina; Schuster, Andreas; Faßhauer, Martin; Staab, Wieland; Paul, Thomas; Lotz, Joachim; Steinmetz, Michael

    2014-07-01

    The classification of clinical severity of Ebstein anomaly still remains a challenge. The aim of this study was to focus on the interaction of the pathologically altered right heart with the anatomically-supposedly-normal left heart and to derive from cardiac magnetic resonance (CMR) a simple imaging measure for the clinical severity of Ebstein anomaly. Twenty-five patients at a mean age of 26±14 years with unrepaired Ebstein anomaly were examined in a prospective study. Disease severity was classified using CMR volumes and functional measurements in comparison with heart failure markers from clinical data, ECG, laboratory and cardiopulmonary exercise testing, and echocardiography. All examinations were completed within 24 hours. A total right/left-volume index was defined from end-diastolic volume measurements in CMR: total right/left-volume index=(RA+aRV+fRV)/(LA+LV). Mean total right/left-volume index was 2.6±1.7 (normal values: 1.1±0.1). This new total right/left-volume index correlated with almost all clinically used biomarkers of heart failure: brain natriuretic peptide (r=0.691; P=0.0003), QRS (r=0.432; P=0.039), peak oxygen consumption/kg (r=-0.479; P=0.024), ventilatory response to carbon dioxide production at anaerobic threshold (r=0.426; P=0.048), the severity of tricuspid regurgitation (r=0.692; P=0.009), tricuspid valve offset (r=0.583; P=0.004), and tricuspid annular plane systolic excursion (r=0.554; P=0.006). Previously described severity indices ([RA+aRV]/[fRV+LA+LV]) and fRV/LV end-diastolic volume corresponded only to some parameters. In patients with Ebstein anomaly, the easily acquired index of right-sided to left-sided heart volumes from CMR correlated well with established heart failure markers. Our data suggest that the total right/left-volume index should be used as a new and simplified CMR measure, allowing more accurate assessment of disease severity than previously described scoring systems. © 2014 American Heart Association, Inc.

  18. Impaired T-wave amplitude adaptation to heart-rate induced by cardiac deconditioning after 5-days of head-down bed-rest

    NASA Astrophysics Data System (ADS)

    Caiani, Enrico G.; Pellegrini, Alessandro; Bolea, Juan; Sotaquira, Miguel; Almeida, Rute; Vaïda, Pierre

    2013-10-01

    The study of QT/RR relationship is important for the clinical evaluation of possible risk of acquired or congenital ventricular tachyarrhythmias. In the hypothesis that microgravity exposure could induce changes in the repolarization mechanisms, our aim was to test if a short 5-days strict 6° head-down bed-rest (HDBR) could induce alterations in the QT/RR relationship and spatial repolarization heterogeneity. Twenty-two healthy men (mean age 31±6) were enrolled as part of the European Space Agency HDBR studies. High fidelity (1000 Hz) 24 h Holter ECG (12-leads, Mortara Instrument) was acquired before (PRE), the last day of HDBR (HDT5), and four days after its conclusion (POST). The night period (23:00-06:30) was selected for analysis. X, Y, Z leads were derived and the vectorcardiogram computed. Selective beat averaging was used to obtain averages of P-QRS-T complexes preceded by the same RR (10 ms bin amplitude, in the range 900-1200 ms). For each averaged waveform (i.e., one for each bin), T-wave maximum amplitude (Tmax), T-wave area (Tarea), RTapex, RTend, ventricular gradient (VG) magnitude and spatial QRS-T angle were computed. Non-parametric Friedman test was applied. Compared to PRE, at HDT5 both RTapex and RTend resulted shortened (-4%), with a decrease in T-wave amplitude (-8%) and area (-13%). VG was diminished by 10%, and QRS-T angle increased by 14°. At POST, QT duration and area parameters, as well as QRS-T angle were restored while Tmax resulted larger than PRE (+5%) and VG was still decreased by 3%. Also, a marked loss in strength of the linear regression with RR was found at HDT5 in Tmax and Tarea, that could represent a new dynamic marker of increased risk for life-threatening arrhythmias. Despite the short-term HDBR, ventricular repolarization during the night period was affected. This should be taken into account in astronauts for risk assessment during space flight.

  19. Is Heart Disease or Cancer the Leading Cause of Death in United States Women?

    PubMed

    Pathak, Elizabeth B

    This paper compares the mortality burden of heart disease versus cancer among women by age, race, and ethnicity. U.S. death and population data for the years 2000 through 2013 were used to calculate heart disease and cancer death rates. Detailed analyses focused on age (15-19 years old to ≥100 years old) and race and ethnicity (Whites, Blacks, Hispanics, Asians and Pacific Islanders (A/PIs), and American Indians and Alaska Natives (AI/ANs)). Among women aged 15 years and older, there were 289,467 heart disease deaths and 276,716 cancer deaths in 2013. The majority of heart disease deaths (51.6%) occurred among women 85 years or older, compared with 18.9% of female cancer deaths. The age-adjusted death rates (per 100,000 population) were 171 (95% confidence interval [CI], 170-171) for heart disease versus 177 (95% CI, 176-178) for cancer. For all racial and ethnic groups, cancer mortality was significantly higher than heart disease mortality among women younger than 80 years of age. For all ages combined, cancer deaths exceeded heart disease deaths among Hispanics, A/PIs, and AI/ANs. Black non-Hispanic women were the only racial/ethnic group who had a higher age-adjusted death rate for heart disease than for cancer: 224 (95% CI, 222-226) versus 207 (95% CI, 205-209). Heart disease remains the leading cause of death among all women combined in the United States by a narrow margin. However, cancer predominantly kills middle-aged and young women, whereas heart disease predominantly kills the very old. New research on the overreporting of heart disease on death certificates for elderly women is needed. National summary statistics obscure the fact that cancer is already the overall leading cause of death for Hispanic women, Asian and Pacific Islander women, and American Indian and Alaska Native women. Copyright © 2016 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  20. Evaluation of mechanical dyssynchrony and myocardial perfusion using phase analysis of gated SPECT imaging in patients with left ventricular dysfunction

    PubMed Central

    Trimble, Mark A.; Borges-Neto, Salvador; Honeycutt, Emily F.; Shaw, Linda K.; Pagnanelli, Robert; Chen, Ji; Iskandrian, Ami E.; Garcia, Ernest V.; Velazquez, Eric J.

    2010-01-01

    Background Using phase analysis of gated single photon emission computed tomography (SPECT) imaging, we examined the relation between myocardial perfusion, degree of electrical dyssynchrony, and degree of SPECT-derived mechanical dyssynchrony in patients with left ventricular (LV) dysfunction. Methods and Results We retrospectively examined 125 patients with LV dysfunction and ejection fraction of 35% or lower. Fourier analysis converts regional myocardial counts into a continuous thickening function, allowing resolution of phase of onset of myocardial thickening. The SD of LV phase distribution (phase SD) and histogram bandwidth describe LV phase dispersion as a measure of dyssynchrony. Heart failure (HF) patients with perfusion abnormalities ities have higher degrees of dyssynchrony measured by median phase SD (45.5° vs 27.7°, P < .0001) and bandwidth (117.0° vs 73.0°, P = .0006). HF patients with prolonged QRS durations have higher degrees of dyssynchrony measured by median phase SD (54.1° vs 34.7°, P < .0001) and bandwidth (136.5° vs 99.0°, P = .0005). Mild to moderate correlations exist between QRS duration and phase analysis indices of phase SD (r = 0.50) and bandwidth (r = 0.40). Mechanical dyssynchrony (phase SD >43°) was 43.2%. Conclusions HF patients with perfusion abnormalities or prolonged QRS durations QRS durations have higher degrees of mechanical dyssynchrony. Gated SPECT myocardial perfusion imaging can quantify myocardial function, perfusion, and dyssynchrony and may help in evaluating patients for cardiac resynchronization therapy. PMID:18761269

  1. Preattentive processing of heart cues and the perception of heart symptoms in congenital heart disease.

    PubMed

    Karsdorp, Petra A; Kindt, Merel; Everaerd, Walter; Mulder, Barbara J M

    2007-08-01

    The present study was aimed at clarifying whether preattentive processing of heart cues results in biased perception of heart sensations in patients with congenital heart disease (ConHD) who are also highly trait anxious. Twenty-six patients with ConHD and 22 healthy participants categorized heart-related (heart rate) or neutral sensations (constant vibration) as either heart or neutral. Both sensations were evoked using a bass speaker that was attached on the chest of the participant. Before each physical sensation, a subliminal heart-related or neutral prime was presented. Biased perception of heart-sensations would become evident by a delayed categorization of the heart-related sensations. In line with the prediction, a combination of high trait anxiety and ConHD resulted in slower responses after a heart-related sensation that was preceded by a subliminal heart cue. Preattentive processing of harmless heart cues may easily elicit overperception of heart symptoms in highly trait anxious patients with ConHD.

  2. Factors Associated With Inadequate Effectiveness of a Multidisciplinary Disease Management Program in Heart Failure Patients Stratified by Galectin 3 Level.

    PubMed

    Liu, Min-Hui; Wang, Chao-Hung; Chiou, Ai-Fu; Yang, Ning-I; Kuo, Li-Tang

    2016-07-21

    This study investigated whether multidisciplinary disease management programs (MDPs) exert the same effects in heart failure (HF) patients across risk levels stratified by galectin-3 (Gal-3) level and what factors are associated with inadequate effectiveness of MDP. We used a longitudinal follow-up design based on a previous randomized trial. A total of 355 stabilized hospitalized HF patients were enrolled. The effects of MDP on death and HF-related rehospitalization were analyzed according to Gal-3 levels. During the 4-year follow-up, Gal-3 levels predicted mortality and composite events (p < .001). Multivariable analysis demonstrated the event-lowering effect of MDP (hazard ratio [HR] = 0.49, p = .001 for death and HR = 0.50, p < .001 for composite events). However, the effect of MDP was inadequate for those with high Gal-3 levels (≥17.9 ng/ml), whose 4-year composite event rate was 43% in the MDP arm. Further analysis showed that, in patients with Gal-3 ≥ 17.9 ng/ml, the independent factors associated with a high composite event rate were no MDP, older age, worse New York Heart Association functional class, no angiotensin-converting enzyme inhibitor or angiotensin II receptor blocker use, higher predischarge natriuretic peptide levels, and wider QRS complexes. The effectiveness of MDP for HF patients at high risk was inadequate. Our findings identified the characteristics of these MDP nonresponders. Better integration of advanced care plans based on strategies guided by Gal-3 level is needed to improve care quality. © The Author(s) 2016.

  3. Bandwidth-narrowed Bragg gratings inscribed in double-cladding fiber by femtosecond laser.

    PubMed

    Shi, Jiawei; Li, Yuhua; Liu, Shuhui; Wang, Haiyan; Liu, Ningliang; Lu, Peixiang

    2011-01-31

    Bragg gratings with the bandwidth(FWHM) narrowed up to 79 pm were inscribed in double-cladding fiber with femtosecond radiation and a phase mask followed by an annealing treatment. With the annealing temperature below a critical value, the bandwidth of Bragg gratings induced by Type I-IR and Type II-IR index change was narrowed without the reduction of reflectivity. The bandwidth narrowing is due to the profile transformation of the refractive index modulation caused by the annealing treatment. This mechanism was verified by comparing bandwidth narrowing processes of FBGs written with different power densities.

  4. 3. Photocopied July 1971 from Photo 741, Jordan Narrows Folder ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Photocopied July 1971 from Photo 741, Jordan Narrows Folder #1, Engineering Department, Utah Power and Light Co., Salt Lake City, Utah. INTERIOR VIEW, JULY 2, 1909. - Salt Lake City Water & Electrical Power Company, Jordan Narrows Hydroelectric Plant, Jordan River, Riverton, Salt Lake County, UT

  5. Reconditioning of Cassini Narrow-Angle Camera

    NASA Image and Video Library

    2002-07-23

    These five images of single stars, taken at different times with the narrow-angle camera on NASA Cassini spacecraft, show the effects of haze collecting on the camera optics, then successful removal of the haze by warming treatments.

  6. Heart Disease

    MedlinePlus

    ... receive Heart Disease and Stroke email updates Submit Heart disease Heart disease is the number one killer of ... about heart disease on other websites View more Heart disease resources Related information Heart-healthy eating Diabetes Stress ...

  7. 1. Photocopied July 1971 from Photo 745, Jordan Narrows Folder ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Photocopied July 1971 from Photo 745, Jordan Narrows Folder #1, Engineering Department, Utah Power and Light Co., Salt Lake City, Utah. JORDAN STATION, JULY 2, 1909. GENERAL VIEW. - Salt Lake City Water & Electrical Power Company, Jordan Narrows Hydroelectric Plant, Jordan River, Riverton, Salt Lake County, UT

  8. Heart transplantation in adults with congenital heart disease.

    PubMed

    Houyel, Lucile; To-Dumortier, Ngoc-Tram; Lepers, Yannick; Petit, Jérôme; Roussin, Régine; Ly, Mohamed; Lebret, Emmanuel; Fadel, Elie; Hörer, Jürgen; Hascoët, Sébastien

    2017-05-01

    With the advances in congenital cardiac surgery and postoperative care, an increasing number of children with complex congenital heart disease now reach adulthood. There are already more adults than children living with a congenital heart defect, including patients with complex congenital heart defects. Among these adults with congenital heart disease, a significant number will develop ventricular dysfunction over time. Heart failure accounts for 26-42% of deaths in adults with congenital heart defects. Heart transplantation, or heart-lung transplantation in Eisenmenger syndrome, then becomes the ultimate therapeutic possibility for these patients. This population is deemed to be at high risk of mortality after heart transplantation, although their long-term survival is similar to that of patients transplanted for other reasons. Indeed, heart transplantation in adults with congenital heart disease is often challenging, because of several potential problems: complex cardiac and vascular anatomy, multiple previous palliative and corrective surgeries, and effects on other organs (kidney, liver, lungs) of long-standing cardiac dysfunction or cyanosis, with frequent elevation of pulmonary vascular resistance. In this review, we focus on the specific problems relating to heart and heart-lung transplantation in this population, revisit the indications/contraindications, and update the long-term outcomes. Copyright © 2017. Published by Elsevier Masson SAS.

  9. Advanced ECG in 2016: is there more than just a tracing?

    PubMed

    Reichlin, Tobias; Abächerli, Roger; Twerenbold, Raphael; Kühne, Michael; Schaer, Beat; Müller, Christian; Sticherling, Christian; Osswald, Stefan

    2016-01-01

    The 12-lead electrocardiogram (ECG) is the most frequently used technology in clinical cardiology. It is critical for evidence-based management of patients with most cardiovascular conditions, including patients with acute myocardial infarction, suspected chronic cardiac ischaemia, cardiac arrhythmias, heart failure and implantable cardiac devices. In contrast to many other techniques in cardiology, the ECG is simple, small, mobile, universally available and cheap, and therefore particularly attractive. Standard ECG interpretation mainly relies on direct visual assessment. The progress in biomedical computing and signal processing, and the available computational power offer fascinating new options for ECG analysis relevant to all fields of cardiology. Several digital ECG markers and advanced ECG technologies have shown promise in preliminary studies. This article reviews promising novel surface ECG technologies in three different fields. (1) For the detection of myocardial ischaemia and infarction, QRS morphology feature analysis, the analysis of high frequency QRS components (HF-QRS) and methods using vectorcardiography as well as ECG imaging are discussed. (2) For the identification and management of patients with cardiac arrhythmias, methods of advanced P-wave analysis are discussed and the concept of ECG imaging for noninvasive localisation of cardiac arrhythmias is presented. (3) For risk stratification of sudden cardiac death and the selection of patients for medical device therapy, several novel markers including an automated QRS-score for scar quantification, the QRS-T angle or the T-wave peak-to-end-interval are discussed. Despite the existing preliminary data, none of the advanced ECG markers and technologies has yet accomplished the transition into clinical practice. Further refinement of these technologies and broader validation in large unselected patient cohorts are the critical next step needed to facilitate translation of advanced ECG technologies

  10. Decreased airway narrowing and smooth muscle contraction in hyperresponsive pigs.

    PubMed

    Turner, Debra J; Noble, Peter B; Lucas, Matthew P; Mitchell, Howard W

    2002-10-01

    Increased smooth muscle contractility or reduced smooth muscle mechanical loads could account for the excessive airway narrowing and hyperresponsiveness seen in asthma. These mechanisms were investigated by using an allergen-induced porcine model of airway hyperresponsiveness. Airway narrowing to electric field stimulation was measured in isolated bronchial segments, over a range of transmural pressures (0-20 cmH(2)O). Contractile responses to ACh were measured in bronchial segments and in isolated tracheal smooth muscle strips isolated from control and test (ovalbumin sensitized and challenged) pigs. Test airways narrowed less than controls (P < 0.0001). Test pigs showed reduced contractility to ACh, both in isolated bronchi (P < 0.01) and smooth muscle strips (P < 0.01). Thus isolated airways from pigs exhibiting airway hyperresponsiveness in vivo are hyporesponsive in vitro. The decreased narrowing in bronchi from hyperresponsive pigs may be related to decreased smooth muscle contractility. These data suggest that mechanisms external to the airway wall may be important to the hyperresponsive nature of sensitized lungs.

  11. Photovoltaic measurement of bandgap narrowing in moderately doped silicon

    NASA Astrophysics Data System (ADS)

    del Alamo, Jesus A.; Swanson, Richard M.; Lietoila, Arto

    1983-05-01

    Solar cells have been fabricated on n-type and p-type moderately doped Si. The shrinkage of the Si bandgap has been obtained by measuring the internal quantum efficiency in the near infrared spectrum ( hv = 1.00-1.25 eV) around the fundamental absorption edge. The results agree with previous optical measurements of bandgap narrowing in Si. It is postulated that this optically-determined bandgap narrowing is the rigid shrinkage of the forbidden gap due to many-body effects. The "device bandgap narrowing" obtained by measuring the pn product in bipolar devices leads to discrepant values because (i) the density of states in the conduction and valence band is modified due to the potential fluctuations originated in the variations in local impurity density, and (ii) the influence of Fermi-Dirac statistics.

  12. Women's Heart Disease: Heart Attack Symptoms

    MedlinePlus

    ... this page please turn JavaScript on. Feature: Women's Heart Disease Heart Attack Symptoms Past Issues / Winter 2014 Table ... NHLBI has uncovered some of the causes of heart diseases and conditions, as well as ways to prevent ...

  13. The effects of narrow and elevated path walking on aperture crossing.

    PubMed

    Hackney, Amy L; Cinelli, Michael E; Denomme, Luke T; Frank, James S

    2015-06-01

    The study investigated the impact that action capabilities have on identifying possibilities for action, particularly how postural threat influences the passability of apertures. To do this, the ability to maintain balance was challenged by manipulating the level of postural threat while walking. First, participants walked along a 7m path and passed through two vertical obstacles spaced 1.1-1.5×the shoulder width apart during normal walking. Next, postural threat was manipulated by having participants complete the task either walking on a narrow, ground level path or on an elevated/narrow path. Despite a decrease in walking speed as well as an increase in trunk sway in both the narrow and elevated/narrow walking conditions, the passability of apertures was only affected when the consequence of instability was greatest. In the elevated/narrow walking condition, individuals maintained a larger critical point (rotated their shoulders for larger aperture widths) compared to normal walking. However, this effect was not observed for the narrow path walking suggesting that the level of postural threat was not enough to impose similar changes to the critical point. Therefore, it appears that manipulating action capabilities by increasing postural threat does indeed influence aperture crossing behavior, however the consequence associated with instability must be high before both gait characteristics and the critical point are affected. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Perfect narrow band absorber for sensing applications.

    PubMed

    Luo, Shiwen; Zhao, Jun; Zuo, Duluo; Wang, Xinbing

    2016-05-02

    We design and numerically investigate a perfect narrow band absorber based on a metal-metal-dielectric-metal structure which consists of periodic metallic nanoribbon arrays. The absorber presents an ultra narrow absorption band of 1.11 nm with a nearly perfect absorption of over 99.9% in the infrared region. For oblique incidence, the absorber shows an absorption more than 95% for a wide range of incident angles from 0 to 50°. Structure parameters to the influence of the performance are investigated. The structure shows high sensing performance with a high sensitivity of 1170 nm/RIU and a large figure of merit of 1054. The proposed structure has great potential as a biosensor.

  15. Assessment of left ventricular mechanical dyssynchrony by phase analysis of gated-SPECT myocardial perfusion imaging and tissue Doppler imaging: comparison between QGS and ECTb software packages.

    PubMed

    Rastgou, Fereydoon; Shojaeifard, Maryam; Amin, Ahmad; Ghaedian, Tahereh; Firoozabadi, Hasan; Malek, Hadi; Yaghoobi, Nahid; Bitarafan-Rajabi, Ahmad; Haghjoo, Majid; Amouzadeh, Hedieh; Barati, Hossein

    2014-12-01

    Recently, the phase analysis of gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) has become feasible via several software packages for the evaluation of left ventricular mechanical dyssynchrony. We compared two quantitative software packages, quantitative gated SPECT (QGS) and Emory cardiac toolbox (ECTb), with tissue Doppler imaging (TDI) as the conventional method for the evaluation of left ventricular mechanical dyssynchrony. Thirty-one patients with severe heart failure (ejection fraction ≤35%) and regular heart rhythm, who referred for gated-SPECT MPI, were enrolled. TDI was performed within 3 days after MPI. Dyssynchrony parameters derived from gated-SPECT MPI were analyzed by QGS and ECTb and were compared with the Yu index and septal-lateral wall delay measured by TDI. QGS and ECTb showed a good correlation for assessment of phase histogram bandwidth (PHB) and phase standard deviation (PSD) (r = 0.664 and r = 0.731, P < .001, respectively). However, the mean value of PHB and PSD by ECTb was significantly higher than that of QGS. No significant correlation was found between ECTb and QGS and the Yu index. Nevertheless, PHB, PSD, and entropy derived from QGS revealed a significant (r = 0.424, r = 0.478, r = 0.543, respectively; P < .02) correlation with septal-lateral wall delay. Despite a good correlation between QGS and ECTb software packages, different normal cut-off values of PSD and PHB should be defined for each software package. There was only a modest correlation between phase analysis of gated-SPECT MPI and TDI data, especially in the population of heart failure patients with both narrow and wide QRS complex.

  16. T wave alternans threshold late after repair of tetralogy of Fallot

    NASA Technical Reports Server (NTRS)

    Cheung, Michael M H.; Weintraub, Robert G.; Cohen, Richard J.; Karl, Tom R.; Wilkinson, James L.; Davis, Andrew M.

    2002-01-01

    INTRODUCTION: Sustained microvolt-level T wave alternans (TWA) is a marker of increased risk for malignant ventricular arrhythmia. There is a significant risk of arrhythmia and sudden death after repair of congenital heart disease. The aim of this study was to determine the prevalence and characteristics of TWA after repair of tetralogy of Fallot (TOF). METHODS AND RESULTS: TWA was evaluated during bicycle exercise in 49 subjects who had consecutively undergone transatrial-transpulmonary repair. Median values for age, age at repair, and follow-up duration were 14.9 years (11.5-20.8), 1.6 years (0.2-4.9), and 11.6 years (9.4-17.2), respectively. All patients were in New York Heart Association functional class I and were asymptomatic. Median QRS duration was 120 msec (80-150). Sustained TWA was detected in 7 (23%) of 31 subjects with adequate tests. In these 7 subjects, median onset heart rate (HR) was 120 (98-155). Median HR threshold as a percentage of predicted maximum HR (220 - age) was 58% (48-77). Sustained TWA prevalence was not significantly different compared with normal subjects (7/31 vs 9/83; P = 0.1). Onset HR in the TOF group was significantly lower [mean (SD) of 122 (20) vs 139 (12), P < 0.05]. In the TOF group with sustained TWA, the TWA occurred in 4 of 7 at <60% predicted maximum HR versus 1 of 9 normal subjects (P < 0.05); 3 of 7 had onset HR <120 versus 0 of 9 normal subjects (P < 0.03). There was no significant difference in age, gender, transannular patch use, restrictive right ventricular physiology, QRS duration, QTc, QT/QRS dispersion, or nonsustained ventricular tachycardia in subjects with or those without sustained TWA. CONCLUSION: The onset HR for sustained TWA is significantly lower after repair of TOF. Further study is required to determine whether this represents an increased risk for arrhythmia in this patient group.

  17. Heart murmurs

    MedlinePlus

    Chest sounds - murmurs; Heart sounds - abnormal; Murmur - innocent; Innocent murmur; Systolic heart murmur; Diastolic heart murmur ... The heart has 4 chambers: Two upper chambers (atria) Two lower chambers (ventricles) The heart has valves that close ...

  18. Influence of the narrow {111} planes on axial and planar ion channeling.

    PubMed

    Motapothula, M; Dang, Z Y; Venkatesan, T; Breese, M B H; Rana, M A; Osman, A

    2012-05-11

    We report channeling patterns where clearly resolved effects of the narrow {111} planes are observed in axial and planar alignments for 2 MeV protons passing through a 55 nm [001] silicon membrane. At certain axes, such as <213> and <314>, the offset in atomic rows forming the narrow {111} planes results in shielding from the large potential at the wide {111} planes, producing a region of shallow, asymmetric potential from which axial channeling patterns have no plane of symmetry. At small tilts from such axes, different behavior is observed from the wide and narrow {111} planes. At planar alignment, distinctive channeling effects due to the narrow planes are observed. As a consequence of the shallow potential well at the narrow planes, incident protons suffer dechanneled trajectories which are excluded from channeling within the wide planes, resulting in an anomalously large scattered beam at {111} alignment.

  19. Prospective Heart Tracking for Whole-heart Magnetic Resonance Angiography

    PubMed Central

    Moghari, Mehdi H.; Geva, Tal; Powell, Andrew J.

    2015-01-01

    Purpose To develop a prospective respiratory-gating technique (Heart-NAV) for use with contrast-enhanced 3D inversion recovery (IR) whole-heart magnetic resonance angiography (MRA) acquisitions that directly tracks heart motion without creating image inflow artifact. Methods With Heart-NAV, 1 of the startup pulses for the whole-heart steady-state free precession MRA sequence is used to collect the centerline of k-space, and its 1-dimensional reconstruction is fed into the standard diaphragm-navigator (NAV) signal analysis process to prospectively gate and track respiratory-induced heart displacement. Ten healthy volunteers underwent non-contrast whole-heart MRA acquisitions using the conventional diaphragm-NAV and Heart-NAV with 5 and 10 mm acceptance windows in a 1.5T scanner. Five patients underwent contrast-enhanced IR whole-heart MRA using a diaphragm-NAV and Heart-NAV with a 5 mm acceptance window. Results For non-contrast whole-heart MRA with both the 5 and 10 mm acceptance windows, Heart-NAV yielded coronary artery vessel sharpness and subjective visual scores that were not significantly different than those using a conventional diaphragm-NAV. Scan time for Heart-NAV was 10% shorter (p<0.05). In patients undergoing contrast-enhanced IR whole-heart MRA, inflow artifact was seen with the diaphragm-NAV but not with Heart-NAV. Conclusion Compared to a conventional diaphragm-NAV, Heart-NAV achieves similar image quality in a slightly shorter scan time and eliminates inflow artifact. PMID:26843458

  20. Changes in the Leading Cause of Death: Recent Patterns in Heart Disease and Cancer Mortality.

    PubMed

    Heron, Melonie; Anderson, Robert N

    2016-08-01

    Data from the National Vital Statistics System •Heart disease has consistently been the leading cause of death in the United States and remained so in 2014. •The gap between the number of heart disease and cancer deaths generally widened from 1950 through 1968, narrowed from 1968 through 2012, and then slightly widened again from 2012 through 2014. •The mortality burden of cancer has surpassed that of heart disease in several states. In 2000, there were only 2 states where cancer was the leading cause of death; in 2014, there were 22. •Heart disease remained the leading cause of death for the non-Hispanic white and non-Hispanic black populations in 2014. •Cancer is now the leading cause of death for the non-Hispanic Asian or Pacific Islander and Hispanic populations. The timing of the leading-cause crossover varied by group. For the total U.S. population, heart disease has been the leading cause of death for decades, with cancer the second leading cause (1). However, the ranking of these causes has varied across demographic group and geographic unit over time. Rankings are based on the number of deaths and reflect mortality burden rather than risk of death (2). This report highlights changes in the mortality burden of heart disease and cancer and presents findings by state, race, and Hispanic origin. All material appearing in this report is in the public domain and may be reproduced or copied without permission; citation as to source, however, is appreciated.

  1. Narrow Angle movie

    NASA Technical Reports Server (NTRS)

    1999-01-01

    This brief three-frame movie of the Moon was made from three Cassini narrow-angle images as the spacecraft passed by the Moon on the way to its closest approach with Earth on August 17, 1999. The purpose of this particular set of images was to calibrate the spectral response of the narrow-angle camera and to test its 'on-chip summing mode' data compression technique in flight. From left to right, they show the Moon in the green, blue and ultraviolet regions of the spectrum in 40, 60 and 80 millisecond exposures, respectively. All three images have been scaled so that the brightness of Crisium basin, the dark circular region in the upper right, is the same in each image. The spatial scale in the blue and ultraviolet images is 1.4 miles per pixel (2.3 kilometers). The original scale in the green image (which was captured in the usual manner and then reduced in size by 2x2 pixel summing within the camera system) was 2.8 miles per pixel (4.6 kilometers). It has been enlarged for display to the same scale as the other two. The imaging data were processed and released by the Cassini Imaging Central Laboratory for Operations (CICLOPS) at the University of Arizona's Lunar and Planetary Laboratory, Tucson, AZ.

    Photo Credit: NASA/JPL/Cassini Imaging Team/University of Arizona

    Cassini, launched in 1997, is a joint mission of NASA, the European Space Agency and Italian Space Agency. The mission is managed by NASA's Jet Propulsion Laboratory, Pasadena, CA, for NASA's Office of Space Science, Washington DC. JPL is a division of the California Institute of Technology, Pasadena, CA.

  2. Narrowing the Gap in Outcomes: Early Years (0-5 Years)

    ERIC Educational Resources Information Center

    Springate, Ian; Atkinson, Mary; Straw, Suzanne; Lamont, Emily; Grayson, Hilary

    2008-01-01

    This report was commissioned by the Local Government Association (LGA) to inform the Department for Children, Schools and Families (DCSF) and LGA work on "Narrowing the Gap." It focuses on early years' provision and presents findings from a review of the best evidence on narrowing the gap in outcomes across the five Every Child Matters…

  3. Spectrally narrowed lasing of a self-injection KrF excimer laser

    NASA Astrophysics Data System (ADS)

    Shimada, Yasuhiro; Wani, Koichi; Miki, Tadaaki; Kawahara, Hidehito; Mimasu, Mutsumi; Ogata, Yoshiro

    1990-08-01

    Spectrally nantwed lasing of a KrF excimer laser has teen ahieved by a self-injection technique using abeam splitter for power extraction aixi intravity etalons for spectral-narrowing. The laser cavity is divithi into an amplifying branch aix! a spectralnarrowing branch. The spectral bandwidth was narrowed to <3pm FWHM with air-sed etalons placed in the spectral-narrowing branch. A laser propagation model was intrOdUced for describing the laser intensity traveling in the laser cavity. The calculated intensityincident onthe intracavityetalons wassmaller thanthat in theconventional Fabry-Perotcavity withplane-parallel mirrors.

  4. Prospective heart tracking for whole-heart magnetic resonance angiography.

    PubMed

    Moghari, Mehdi H; Geva, Tal; Powell, Andrew J

    2017-02-01

    To develop a prospective respiratory-gating technique (Heart-NAV) for use with contrast-enhanced three-dimensional (3D) inversion recovery (IR) whole-heart magnetic resonance angiography (MRA) acquisitions that directly tracks heart motion without creating image inflow artifact. With Heart-NAV, one of the startup pulses for the whole-heart steady-state free precession MRA sequence is used to collect the centerline of k-space, and its one-dimensional reconstruction is fed into the standard diaphragm-navigator (NAV) signal analysis process to prospectively gate and track respiratory-induced heart displacement. Ten healthy volunteers underwent non-contrast whole-heart MRA acquisitions using the conventional diaphragm-NAV and Heart-NAV with 5 and 10-mm acceptance windows in a 1.5T scanner. Five patients underwent contrast-enhanced IR whole-heart MRA using a diaphragm-NAV and Heart-NAV with a 5-mm acceptance window. For non-contrast whole-heart MRA with both the 5 and 10-mm acceptance windows, Heart-NAV yielded coronary artery vessel sharpness and subjective visual scores that were not significantly different than those using a conventional diaphragm-NAV. Scan time for Heart-NAV was 10% shorter (p < 0.05). In patients undergoing contrast-enhanced IR whole-heart MRA, inflow artifact was seen with the diaphragm-NAV but not with Heart-NAV. Compared with a conventional diaphragm-NAV, Heart-NAV achieves similar image quality in a slightly shorter scan time and eliminates inflow artifact. Magn Reson Med 77:759-765, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  5. Heart Failure

    MedlinePlus

    Heart failure is a condition in which the heart can't pump enough blood to meet the body's needs. Heart failure does not mean that your heart has stopped ... and shortness of breath Common causes of heart failure are coronary artery disease, high blood pressure and ...

  6. Transitioning to a narrow path: the impact of fear of falling in older adults.

    PubMed

    Dunlap, Pamela; Perera, Subashan; VanSwearingen, Jessie M; Wert, David; Brach, Jennifer S

    2012-01-01

    Everyday ambulation requires navigation of variable terrain, transitions from wide to narrow pathways, and avoiding obstacles. While the effect of age on the transition to a narrow path has been examined briefly, little is known about the impact of fear of falling on gait during the transition to a narrow path. The purpose was to examine the effect of age and fear of falling on gait during transition to a narrow path. In 31 young, mean age=25.3 years, and 30 older adults, mean age=79.6 years, step length, step time, step width and gait speed were examined during usual and transition to narrow pathway using an instrumented walkway. During the transition to narrow walk condition, fearful older adults compared to young had a wider step width (0.06 m vs 0.04 m) prior to the narrow path and took shorter steps (0.53 m vs 0.72 m; p<0.001). Compared to non-fearful older adults, fearful older adults walked slower and took shorter steps during narrow path walking (gait speed: 1.1m/s vs 0.82 m/s; p=0.01; step length: 0.60 m vs 0.47 m; p=0.03). In young and non-fearful older adults narrow path gait was similar to usual gait. Whereas older adults who were fearful, walked slower (0.82 m/s vs 0.91 m/s; p=0.001) and took shorter steps (0.44 m vs 0.53 m; p=0.004) during narrow path walking compared to usual walking. Changes in gait characteristics with transitioning to a narrow pathway were greater for fear of falling than for age. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. A narrow band pattern-matching model of vowel perception

    NASA Astrophysics Data System (ADS)

    Hillenbrand, James M.; Houde, Robert A.

    2003-02-01

    The purpose of this paper is to propose and evaluate a new model of vowel perception which assumes that vowel identity is recognized by a template-matching process involving the comparison of narrow band input spectra with a set of smoothed spectral-shape templates that are learned through ordinary exposure to speech. In the present simulation of this process, the input spectra are computed over a sufficiently long window to resolve individual harmonics of voiced speech. Prior to template creation and pattern matching, the narrow band spectra are amplitude equalized by a spectrum-level normalization process, and the information-bearing spectral peaks are enhanced by a ``flooring'' procedure that zeroes out spectral values below a threshold function consisting of a center-weighted running average of spectral amplitudes. Templates for each vowel category are created simply by averaging the narrow band spectra of like vowels spoken by a panel of talkers. In the present implementation, separate templates are used for men, women, and children. The pattern matching is implemented with a simple city-block distance measure given by the sum of the channel-by-channel differences between the narrow band input spectrum (level-equalized and floored) and each vowel template. Spectral movement is taken into account by computing the distance measure at several points throughout the course of the vowel. The input spectrum is assigned to the vowel template that results in the smallest difference accumulated over the sequence of spectral slices. The model was evaluated using a large database consisting of 12 vowels in /hVd/ context spoken by 45 men, 48 women, and 46 children. The narrow band model classified vowels in this database with a degree of accuracy (91.4%) approaching that of human listeners.

  8. Heart MRI

    MedlinePlus

    Magnetic resonance imaging - cardiac; Magnetic resonance imaging - heart; Nuclear magnetic resonance - cardiac; NMR - cardiac; MRI of the heart; Cardiomyopathy - MRI; Heart failure - MRI; Congenital heart disease - MRI

  9. Heart rate as an independent risk factor in patients with multiple organ dysfunction: a prospective, observational study.

    PubMed

    Hoke, Robert S; Müller-Werdan, Ursula; Lautenschläger, Christine; Werdan, Karl; Ebelt, Henning

    2012-02-01

    To study the association between baseline heart rate and outcome in patients with multiple organ dysfunction (MODS) as well as the course of heart rate over the first 4 days during MODS. Prospective observational study in 89 patients with MODS, defined as an APACHE-II score ≥20. Baseline heart rate (HR(0)) was determined over a 60-minute period at the time of MODS diagnosis. 28-day all-cause mortality was the primary endpoint of the study, a fall of the APACHE-II score by 4 points or more from day 0 to day 4 constituted the secondary endpoint. Hazard ratios for heart rate of 90 beats per minute (bpm) or greater relative to less than 90 bpm were calculated using Cox proportional hazards model and adjusted for confounding variables. Median baseline heart rate was 83 bpm in survivors and 92 bpm in non-survivors (p = 0.048). 28-day mortality was 32 and 61% in patients with HR(0) < 90 bpm and HR(0) ≥ 90 bpm, respectively. The adjusted hazard ratio for 28-day mortality was 2.30 (95% confidence interval 1.21-4.36, p = 0.001) for HR(0) ≥ 90 bpm relative to HR(0) < 90 bpm. No correlation was found between baseline heart rate and the secondary endpoint. From day 0 to day 4, heart rate remained elevated in all patients, as well as in survivors and non-survivors. A heart rate ≥90 bpm at the time of MODS diagnosis is an independent risk factor for increased 28-day mortality. As in patients with cardiovascular conditions such as coronary heart disease or chronic heart failure, heart rate might constitute a target for heart rate-lowering therapy in the narrow initial treatment window of MODS.

  10. The extremely narrow-caliber esophagus is a treatment-resistant subphenotype of eosinophilic esophagitis.

    PubMed

    Eluri, Swathi; Runge, Thomas M; Cotton, Cary C; Burk, Caitlin M; Wolf, W Asher; Woosley, John T; Shaheen, Nicholas J; Dellon, Evan S

    2016-06-01

    Some patients with eosinophilic esophagitis (EoE) have an extremely narrow esophagus, but the characteristics of this group have not been extensively described. We aimed to characterize the narrow-caliber phenotype of EoE, determine associated risk factors, and identify differences in treatment response in this subgroup of patients. This retrospective cohort study from 2001 to 2014 included subjects with a new diagnosis of EoE per consensus guidelines. Demographic, endoscopic, histologic, and treatment response data were extracted from medical records. An extremely narrow-caliber esophagus was defined when a neonatal endoscope was required to traverse the esophagus due to the inability to pass an adult endoscope. Patients with and without an extremely narrow-caliber esophagus were compared. Multivariable logistical regression was performed to assess treatment outcomes. Of 513 patients with EoE, 46 (9%) had an extremely narrow-caliber esophagus. These patients were older (33 vs 22 years; P < .01), had longer symptom duration (11 vs 3 years; P < .01), more dysphagia (98% vs 66%; P < .01), and food impactions (53% vs 31%; P < .01). Dilation was more common with extreme narrowing (69% vs 17%; P < .01). Patients with a narrow-caliber esophagus were more refractory to steroid treatment, with lower symptom (56% vs 85%), endoscopic (52% vs 76%), and histologic (33% vs 63%) responses (P < .01 for all), and these differences persisted after multivariate analysis. The extremely narrow-caliber esophagus is a more treatment-resistant subphenotype of EoE and is characterized by longer symptom duration and the need for multiple dilations. Recognition of an extremely narrow-caliber esophagus at diagnosis of EoE can provide important prognostic information. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  11. Heart Health - Heart Disease: Symptoms, Diagnosis, Treatment

    MedlinePlus

    ... Bar Home Current Issue Past Issues Cover Story Heart Health Heart Disease: Symptoms, Diagnosis, Treatment Past Issues / Winter 2009 ... of this page please turn Javascript on. Most heart attacks happen when a clot in the coronary ...

  12. Alkaline phosphatase levels in patients with coronary heart disease saliva and its relation with periodontal status

    NASA Astrophysics Data System (ADS)

    Yunita, Dina Suci; Masulili, Sri Lelyati C.; Tadjoedin, Fatimah M.; Radi, Basuni

    2017-02-01

    Coronary heart disease (CHD) is a disease that causes narrowing of the coronary arteries. Currently, there is a hypothesis regarding periodontal infection that increases risk for heart disease. Alkaline phosphatase (ALP) as a marker of inflammation will increase in atherosclerosis and periodontal disease. The objective of this research is analyzing the relationship between the levels of alkaline phosphatase in saliva with periodontal status in patients with CHD and non CHD. Here, saliva of 104 subjects were taken, each 1 ml, and levels of Alkaline Phosphatase was analyzed using Abbott ci4100 architect. We found that no significant difference of Alkaline Phosphatase levels in saliva between CHD patients and non CHD. Therefore, it can be concluded that Alkaline Phosphatase levels in patients with CHD saliva was higher than non CHD and no association between ALP levels with periodontal status.

  13. Heart Health: The Heart Truth Campaign 2009

    MedlinePlus

    ... Bar Home Current Issue Past Issues Cover Story Heart Health The Heart Truth Campaign 2009 Past Issues / Winter 2009 Table ... one of the celebrities supporting this year's The Heart Truth campaign. Both R&B singer Ashanti (center) ...

  14. Women's Heart Disease: Heart Disease Risk Factors

    MedlinePlus

    ... this page please turn JavaScript on. Feature: Women's Heart Disease Heart Disease Risk Factors Past Issues / Winter 2014 Table ... or habits may raise your risk for coronary heart disease (CHD). These conditions are known as risk ...

  15. Reliability and failure modes of narrow implant systems.

    PubMed

    Hirata, Ronaldo; Bonfante, Estevam A; Anchieta, Rodolfo B; Machado, Lucas S; Freitas, Gileade; Fardin, Vinicius P; Tovar, Nick; Coelho, Paulo G

    2016-09-01

    Narrow implants are indicated in areas of limited bone width or when grafting is nonviable. However, the reduction of implant diameter may compromise their performance. This study evaluated the reliability of several narrow implant systems under fatigue, after restored with single-unit crowns. Narrow implant systems were divided (n = 18 each), as follows: Astra (ASC); BioHorizons (BSC); Straumann Roxolid (SNC), Intra-Lock (IMC), and Intra-Lock one-piece abutment (ILO). Maxillary central incisor crowns were cemented and subjected to step-stress accelerated life testing in water. Use level probability Weibull curves and reliability for a mission of 100,000 cycles at 130- and 180-N loads (90 % two-sided confidence intervals) were calculated. Scanning electron microscopy was used for fractography. Reliability for 100,000 cycles at 130 N was ∼99 % in group ASC, ∼99 % in BSC, ∼96 % in SNC, ∼99 % in IMC, and ∼100 % in ILO. At 180 N, reliability of ∼34 % resulted for the ASC group, ∼91 % for BSC, ∼53 % for SNC, ∼70 % for IMC, and ∼99 % for ILO. Abutment screw fracture was the main failure mode for all groups. Reliability was not different between systems for 100,000 cycles at the 130-N load. A significant decrease was observed at the 180-N load for ASC, SNC, and IMC, whereas it was maintained for BSC and ILO. The investigated narrow implants presented mechanical performance under fatigue that suggests their safe use as single crowns in the anterior region.

  16. Abnormalities of capillary microarchitecture in a rat model of coronary ischemic congestive heart failure

    PubMed Central

    Chen, Jiqiu; Yaniz-Galende, Elisa; Kagan, Heather J.; Liang, Lifan; Hekmaty, Saboor; Giannarelli, Chiara

    2015-01-01

    The aim of the present study is to explore the role of capillary disorder in coronary ischemic congestive heart failure (CHF). CHF was induced in rats by aortic banding plus ischemia-reperfusion followed by aortic debanding. Coronary arteries were perfused with plastic polymer containing fluorescent dye. Multiple fluorescent images of casted heart sections and scanning electric microscope of coronary vessels were obtained to characterize changes in the heart. Cardiac function was assessed by echocardiography and in vivo hemodynamics. Stenosis was found in all levels of the coronary arteries in CHF. Coronary vasculature volume and capillary density in remote myocardium were significantly increased in CHF compared with control. This occurred largely in microvessels with a diameter of ≤3 μm. Capillaries in CHF had a tortuous structure, while normal capillaries were linear. Capillaries in CHF had inconsistent diameters, with assortments of narrowed and bulged segments. Their surfaces appeared rough, potentially indicating endothelial dysfunction in CHF. Segments of main capillaries between bifurcations were significantly shorter in length in CHF than in control. Transiently increasing preload by injecting 50 μl of 30% NaCl demonstrated that the CHF heart had lower functional reserve; this may be associated with congestion in coronary microcirculation. Ischemic coronary vascular disorder is not limited to the main coronary arteries, as it occurs in arterioles and capillaries. Capillary disorder in CHF included stenosis, deformed structure, proliferation, and roughened surfaces. This disorder in the coronary artery architecture may contribute to the reduction in myocyte contractility in the setting of heart failure. PMID:25659485

  17. Narrowing of the Coronary Sinus: A Device-Based Therapy for Persistent Angina Pectoris.

    PubMed

    Konigstein, Maayan; Verheye, Stefan; Jolicœur, E Marc; Banai, Shmuel

    2016-01-01

    Alongside the remarkable advances in medical and invasive therapies for the treatment of ischemic heart disease, an increasing number of patients with advanced coronary artery disease unsuitable for revascularization continue to suffer from angina pectoris despite optimal medical therapy. Patients with chronic angina have poor quality of life and increased levels of anxiety and depression. A considerable number of innovative therapeutic modalities for the treatment of chronic angina have been investigated over the years; however, none of these therapeutic options has become a standard of care, and none are widely utilized. Current treatment options for refractory angina focus on medical therapy and secondary risk factor modification. Interventions to create increased pressure in the coronary sinus may alleviate myocardial ischemia by forcing redistribution of coronary blood flow from the less ischemic subepicardium to the more ischemic subendocardium, thus relieving symptoms of ischemia. Percutaneous, transvenous implantation of a balloon expandable, hourglass-shaped, stainless steel mesh in the coronary sinus to create a fixed focal narrowing and to increase backwards pressure, may serve as a new device-based therapy destined for the treatment of refractory angina pectoris.

  18. 76 FR 60733 - Drawbridge Operation Regulations; Narrow Bay, Smith Point, NY

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-30

    ... Operation Regulations; Narrow Bay, Smith Point, NY AGENCY: Coast Guard, DHS. ACTION: Notice of temporary... deviation from the regulation governing the operation of the Smith Point Bridge, 6.1, across Narrow Bay, between Smith Point and Fire Island, New York. The deviation is necessary to facilitate bridge...

  19. Electronic structure descriptor for the discovery of narrow-band red-emitting phosphors

    DOE PAGES

    Wang, Zhenbin; Chu, Iek -Heng; Zhou, Fei; ...

    2016-05-09

    Narrow-band red-emitting phosphors are a critical component of phosphor-converted light-emitting diodes for highly efficient illumination-grade lighting. In this work, we report the discovery of a quantitative descriptor for narrow-band Eu 2+-activated emission identified through a comparison of the electronic structures of known narrow-band and broad-band phosphors. We find that a narrow emission bandwidth is characterized by a large splitting of more than 0.1 eV between the two highest Eu 2+ 4 f 7 bands. By incorporating this descriptor in a high-throughput first-principles screening of 2259 nitride compounds, we identify five promising new nitride hosts for Eu 2+-activated red-emitting phosphors thatmore » are predicted to exhibit good chemical stability, thermal quenching resistance, and quantum efficiency, as well as narrow-band emission. Lastly, our findings provide important insights into the emission characteristics of rare-earth activators in phosphor hosts and a general strategy to the discovery of phosphors with a desired emission peak and bandwidth.« less

  20. Electronic structure descriptor for the discovery of narrow-band red-emitting phosphors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zhenbin; Chu, Iek -Heng; Zhou, Fei

    Narrow-band red-emitting phosphors are a critical component of phosphor-converted light-emitting diodes for highly efficient illumination-grade lighting. In this work, we report the discovery of a quantitative descriptor for narrow-band Eu 2+-activated emission identified through a comparison of the electronic structures of known narrow-band and broad-band phosphors. We find that a narrow emission bandwidth is characterized by a large splitting of more than 0.1 eV between the two highest Eu 2+ 4 f 7 bands. By incorporating this descriptor in a high-throughput first-principles screening of 2259 nitride compounds, we identify five promising new nitride hosts for Eu 2+-activated red-emitting phosphors thatmore » are predicted to exhibit good chemical stability, thermal quenching resistance, and quantum efficiency, as well as narrow-band emission. Lastly, our findings provide important insights into the emission characteristics of rare-earth activators in phosphor hosts and a general strategy to the discovery of phosphors with a desired emission peak and bandwidth.« less

  1. A novel LabVIEW-based multi-channel non-invasive abdominal maternal-fetal electrocardiogram signal generator.

    PubMed

    Martinek, Radek; Kelnar, Michal; Koudelka, Petr; Vanus, Jan; Bilik, Petr; Janku, Petr; Nazeran, Homer; Zidek, Jan

    2016-02-01

    This paper describes the design, construction, and testing of a multi-channel fetal electrocardiogram (fECG) signal generator based on LabVIEW. Special attention is paid to the fetal heart development in relation to the fetus' anatomy, physiology, and pathology. The non-invasive signal generator enables many parameters to be set, including fetal heart rate (FHR), maternal heart rate (MHR), gestational age (GA), fECG interferences (biological and technical artifacts), as well as other fECG signal characteristics. Furthermore, based on the change in the FHR and in the T wave-to-QRS complex ratio (T/QRS), the generator enables manifestations of hypoxic states (hypoxemia, hypoxia, and asphyxia) to be monitored while complying with clinical recommendations for classifications in cardiotocography (CTG) and fECG ST segment analysis (STAN). The generator can also produce synthetic signals with defined properties for 6 input leads (4 abdominal and 2 thoracic). Such signals are well suited to the testing of new and existing methods of fECG processing and are effective in suppressing maternal ECG while non-invasively monitoring abdominal fECG. They may also contribute to the development of a new diagnostic method, which may be referred to as non-invasive trans-abdominal CTG +  STAN. The functional prototype is based on virtual instrumentation using the LabVIEW developmental environment and its associated data acquisition measurement cards (DAQmx). The generator also makes it possible to create synthetic signals and measure actual fetal and maternal ECGs by means of bioelectrodes.

  2. Efficiency of timing delays and electrode positions in optimization of biventricular pacing: a simulation study.

    PubMed

    Miri, Raz; Graf, Iulia M; Dössel, Olaf

    2009-11-01

    Electrode positions and timing delays influence the efficacy of biventricular pacing (BVP). Accordingly, this study focuses on BVP optimization, using a detailed 3-D electrophysiological model of the human heart, which is adapted to patient-specific anatomy and pathophysiology. The research is effectuated on ten heart models with left bundle branch block and myocardial infarction derived from magnetic resonance and computed tomography data. Cardiac electrical activity is simulated with the ten Tusscher cell model and adaptive cellular automaton at physiological and pathological conduction levels. The optimization methods are based on a comparison between the electrical response of the healthy and diseased heart models, measured in terms of root mean square error (E(RMS)) of the excitation front and the QRS duration error (E(QRS)). Intra- and intermethod associations of the pacing electrodes and timing delays variables were analyzed with statistical methods, i.e., t -test for dependent data, one-way analysis of variance for electrode pairs, and Pearson model for equivalent parameters from the two optimization methods. The results indicate that lateral the left ventricle and the upper or middle septal area are frequently (60% of cases) the optimal positions of the left and right electrodes, respectively. Statistical analysis proves that the two optimization methods are in good agreement. In conclusion, a noninvasive preoperative BVP optimization strategy based on computer simulations can be used to identify the most beneficial patient-specific electrode configuration and timing delays.

  3. Real-world cardiovascular assessment of mirabegron treatment in patients with overactive bladder and concomitant cardiovascular disease: Results of a Japanese post-marketing study.

    PubMed

    Katoh, Takao; Kuwamoto, Kana; Kato, Daisuke; Kuroishi, Kentarou

    2016-12-01

    To assess the effect of 25 or 50 mg mirabegron on cardiovascular end-points and adverse drug reactions in real-world Japanese patients with overactive bladder and cardiovascular disease. Participants had overactive bladder, a history of/coexisting cardiovascular disease and a 12-lead electrocardiogram carried out ≤7 days before initiating 4 weeks of mirabegron treatment. Patients with "serious cardiovascular disease" (class III or IV on the New York Heart Association functional classification and further confirmed by expert analysis) were excluded. Patient demographics, physical characteristics and cardiovascular history were recorded. After 4 weeks, patients underwent another electrocardiogram. Incidence of cardiovascular adverse drug reactions and change from baseline in electrocardiogram parameters (RR, PR, QRS intervals, Fridericia's corrected QT and heart rate) were assessed. Of 316 patients registered, 236 met criteria and had baseline/post-dose electrocardiograms: 61.9% male; 60.2% aged ≥75 years; 93.6% with coexisting cardiovascular disease, notably, arrhythmia (67.8%) and angina pectoris (19.1%). Starting mirabegron daily doses were 25 mg (19.9%) or 50 mg (80.1%). The incidence of cardiovascular adverse drug reactions was 5.51%. After 4 weeks, the mean heart rate increased by 1.24 b.p.m. (statistically significant, but clinically acceptable as per previous trials). No significant changes were observed in PR, QRS or Fridericia's corrected QT. No significant correlations in the total population or age-/sex-segregated subgroups were observed between baseline Fridericia's corrected QT and change at 4 weeks. No correlation for heart rate versus change from baseline heart rate with treatment was observed. Mirabegron was well tolerated in real-world Japanese patients with overactive bladder and coexisting cardiovascular disease. No unexpected cardiovascular safety concerns were observed. © 2016 The Japanese Urological Association.

  4. Narrow-Band Applications of Communications Satellites.

    ERIC Educational Resources Information Center

    Cowlan, Bert; Horowitz, Andrew

    This paper attempts to describe the advantages of "narrow-band" applications of communications satellites for education. It begins by discussing the general controversy surrounding the use of satellites in education, by placing the concern within the larger context of the general debate over the uses of new technologies in education, and by…

  5. CHARACTERIZATION OF A NARROW SPECTRUM ANTIMICROBIAL THAT EXHIBITS SPECIFIC ACTIVITY AGAINST UROPATHOGENIC BACTERIA

    DTIC Science & Technology

    2017-08-28

    NARROW-SPECTRUM ANTIMICROBIAL THAT EXHIBITS SPECIFIC ACTIVITY AGAINST UROPATHOGENIC BACTERIA by Caitlin M. Barrows Courtney M. Cowell Jennifer...From - To) October 2015 – September 2016 4. TITLE AND SUBTITLE CHARACTERIZATION OF A NARROW-SPECTRUM ANTIMICROBIAL THAT EXHIBITS SPECIFIC ACTIVITY ...objective of the work described in this report is to identify a narrow-spectrum antimicrobial that exhibits targeted activity against uropathogenic

  6. Design, Construction, Demonstration and Delivery of an Automated Narrow Gap Welding System.

    DTIC Science & Technology

    1983-03-31

    evaluated on the Narrow Gap welding system. By using the combinational qas shielding assembly, it is now possible to reduce the gas flow rates to a value...AD-A145 496 DESIGN CONSTRUCTION DEMONSTRATION AND DE IVER OF AN AUTOMATED NARROW GAP WELDING SYSTEM(U) CRC AUTOMATIC WELDING CO HODSTON SX 31 MAR 83...STANDARDS-963 - A CRC REPORT NO. NAV A/W 7 0PHASE 3 REPORT ON SDESIGN, CONSTRUCTION, DEMONSTRATION AND DELIVERY OF AN AUTOMATED NARROW GAP WELDING

  7. Heart Attack

    MedlinePlus

    Each year almost 800,000 Americans have a heart attack. A heart attack happens when blood flow to the heart suddenly ... it's important to know the symptoms of a heart attack and call 9-1-1 if you or ...

  8. Temporal intensity interferometry for characterization of very narrow spectral lines

    NASA Astrophysics Data System (ADS)

    Tan, P. K.; Kurtsiefer, C.

    2017-08-01

    Some stellar objects exhibit very narrow spectral lines in the visible range additional to their blackbody radiation. Natural lasing has been suggested as a mechanism to explain narrow lines in Wolf-Rayet stars. However, the spectral resolution of conventional astronomical spectrographs is still about two orders of magnitude too low to test this hypothesis. We want to resolve the linewidth of narrow spectral emissions in starlight. A combination of spectral filtering with single-photon-level temporal correlation measurements breaks the resolution limit of wavelength-dispersing spectrographs by moving the linewidth measurement into the time domain. We demonstrate in a laboratory experiment that temporal intensity interferometry can determine a 20-MHz-wide linewidth of Doppler-broadened laser light and identify a coherent laser light contribution in a blackbody radiation background.

  9. Narrow-line magneto-optical cooling and trapping of strongly magnetic atoms.

    PubMed

    Berglund, Andrew J; Hanssen, James L; McClelland, Jabez J

    2008-03-21

    Laser cooling on weak transitions is a useful technique for reaching ultracold temperatures in atoms with multiple valence electrons. However, for strongly magnetic atoms a conventional narrow-line magneto-optical trap (MOT) is destabilized by competition between optical and magnetic forces. We overcome this difficulty in Er by developing an unusual narrow-line MOT that balances optical and magnetic forces using laser light tuned to the blue side of a narrow (8 kHz) transition. The trap population is spin polarized with temperatures reaching below 2 muK. Our results constitute an alternative method for laser cooling on weak transitions, applicable to rare-earth-metal and metastable alkaline earth elements.

  10. 78 FR 23845 - Drawbridge Operation Regulations; Narrow Bay, Smith Point, NY

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-23

    ... Operation Regulations; Narrow Bay, Smith Point, NY AGENCY: Coast Guard, DHS. ACTION: Notice of temporary... deviation from the regulation governing the operation of the Smith Point Bridge, mile 6.1, across Narrow Bay, between Smith Point and Fire Island, New York. The deviation is necessary to facilitate the Smith Point...

  11. Heart Transplantation

    MedlinePlus

    A heart transplant removes a damaged or diseased heart and replaces it with a healthy one. The healthy heart comes from a donor who has died. It is the last resort for people with heart failure when all other treatments have failed. The ...

  12. Heart Diseases

    MedlinePlus

    ... you're like most people, you think that heart disease is a problem for others. But heart disease is the number one killer in the ... of disability. There are many different forms of heart disease. The most common cause of heart disease ...

  13. Ultra-narrow-linewidth Brillouin/erbium fiber laser

    NASA Astrophysics Data System (ADS)

    Chen, Mo; Wang, Chenyu; Wang, Jianfei; Luo, Hong; Meng, Zhou

    2018-02-01

    Ultra-narrow-linewidth lasers are of great interest in many applications, such as precise spectroscopy, optical communications, and sensors. Stimulated Brillouin scattering (SBS), as one of the main nonlinear effects in fibers, is capable of generating narrow-linewidth light emission. We establish a compact Brillouin/erbium fiber laser (BEFL) utilizing 4-m erbium-doped fiber as both the Brillouin gain and linear media. A 360-kHz-linewidth laser diode is injected into the cavity as the Brillouin pump (BP) light and generates Brillouin Stokes lasing light. Both of the phase noise of the BP and BEFL output are measured by a high-accuracy unbalanced Michelson interferometer. It is demonstrated that 53- dB phase noise reduction is achieved after the BP is transferred into Brillouin Stokes emission. The linewidth of the BEFL is indicated at Hz-range by both calculation and experiment.

  14. 2013 update on congenital heart disease, clinical cardiology, heart failure, and heart transplant.

    PubMed

    Subirana, M Teresa; Barón-Esquivias, Gonzalo; Manito, Nicolás; Oliver, José M; Ripoll, Tomás; Lambert, Jose Luis; Zunzunegui, José L; Bover, Ramon; García-Pinilla, José Manuel

    2014-03-01

    This article presents the most relevant developments in 2013 in 3 key areas of cardiology: congenital heart disease, clinical cardiology, and heart failure and transplant. Within the area of congenital heart disease, we reviewed contributions related to sudden death in adult congenital heart disease, the importance of specific echocardiographic parameters in assessing the systemic right ventricle, problems in patients with repaired tetralogy of Fallot and indication for pulmonary valve replacement, and confirmation of the role of specific factors in the selection of candidates for Fontan surgery. The most recent publications in clinical cardiology include a study by a European working group on correct diagnostic work-up in cardiomyopathies, studies on the cost-effectiveness of percutaneous aortic valve implantation, a consensus document on the management of type B aortic dissection, and guidelines on aortic valve and ascending aortic disease. The most noteworthy developments in heart failure and transplantation include new American guidelines on heart failure, therapeutic advances in acute heart failure (serelaxin), the management of comorbidities such as iron deficiency, risk assessment using new biomarkers, and advances in ventricular assist devices. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  15. Quantification of ventricular resynchronization reserve by radionuclide phase analysis in heart failure patients: a prospective long-term study.

    PubMed

    Dauphin, Raphael; Nonin, Emilie; Bontemps, Laurence; Vincent, Madeleine; Pinel, Alain; Bonijoly, Serge; Barborier, Denis; Ribier, Arnaud; Fernandes, Christine Mestre; Bert-Marcaz, Patrick; Itti, Roland; Chevalier, Philippe

    2011-03-01

    Phase analysis, developed to assess dyssynchrony from ECG-gated radionuclide ventriculography, has shown promising results. We hypothesized that quantifying the cardiac resynchronization reserve, that is, the extent of response to cardiac resynchronization therapy (CRT), by radionuclide imaging could potentially identify patients who are best suited for CRT. Seventy-four patients ages 64.8±10.1 years were prospectively studied from July 2004 to July 2006, of whom 62.2% and 37.8%, respectively, were in New York Heart Association class 3 and 4. Mean QRS width was 173±25 ms. ECG-gated radionuclide ventriculography to quantify interventricular and intraventricular dyssynchrony was performed at baseline with and without CRT and at the 3-month follow-up visit. Amino-terminal-pro-brain natriuretic peptide (NT-pro-BNP) levels were also determined at baseline and at 3 months. During a mean follow-up of 10.1±7.6 months, there were 37 (50%) clinical events that defined the nonresponder group, including cardiac death or readmission for worsening heart failure. In multivariate Cox model analysis, higher NT-pro-BNP blood levels were associated with a significant increase in the risk for event (hazard ratio=1.085 for a 100 pg/L increase in NT-pro-BNP; 95% confidence interval, 1.014 to 1.161). Each 10° elevation in intraventricular dyssynchrony was associated with a decrease in the risk of events (hazard ratio=0.456, 95% confidence interval, 0.304 to 0.683). Receiver operating characteristic curve analysis demonstrated that an interventricular dyssynchrony cutoff value of 25.5° for intraventricular synchrony yielded 91.4% sensitivity and 84.4% specificity for predicting a good response to CRT. The quantification of interventricular dyssynchrony with radionuclide phase analysis suggests that early postimplantation interventricular dyssynchrony may provide identification of CRT responders.

  16. A technique for production of nanocrystalline cellulose with a narrow size distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bai, Wen; Holbery, James D.; Li, Kaichang

    2009-02-01

    Nanocrystalline cellulose (NCC) was prepared by sulfuric acid hydrolysis of microcrystalline cellulose. A differential centrifugation technique was studied to obtain NCC whiskers with a narrow size distribution. It was shown that the volume of NCC in different fractions had an inverse relationship with relative centrifugal force (RCF). The length of NCC whiskers was also fractionized by differential RCF. The aspect ratio of NCC in different fractions had a relatively narrow range. This technique provides an easy way of producing NCC whiskers with a narrow size distribution.

  17. Adverse effects of prohibiting narrow provider networks.

    PubMed

    Howard, David H

    2014-08-14

    Many insurers participating in the new insurance exchanges are controlling costs by offering plans with narrow provider networks. Proposed regulations would promote network adequacy, but a pro-provider stance may not be inherently pro-consumer or even pro-patient.

  18. Pediatric heart surgery

    MedlinePlus

    Heart surgery - pediatric; Heart surgery for children; Acquired heart disease; Heart valve surgery - children ... There are many kinds of heart defects. Some are minor, and others are more serious. Defects can occur inside the heart or in the large blood vessels ...

  19. Accuracy of manual QRS duration assessment: its importance in patient selection for cardiac resynchronization and implantable cardioverter defibrillator therapy.

    PubMed

    Tomlinson, David R; Bashir, Yaver; Betts, Timothy R; Rajappan, Kim

    2009-05-01

    Patients with left ventricular systolic dysfunction and electrocardiographic QRS duration (QRSd) >or=120 ms may obtain symptomatic and prognostic benefits from cardiac resynchronization therapy (CRT). However, clinical trials do not describe the methods used to measure QRSd. We investigated the effect of electrocardiogram (ECG) display format and paper speed on the accuracy of manual QRSd assessment and concordance of manual QRSd with computer-calculated mean and maximal QRSd. Six cardiologists undertook QRSd measurements on ECGs, with computer-calculated mean QRSd close to 120 ms. Display formats were 12-lead, 6-limb, and 6-precordial leads, each at 25 and 50 mm/s. When the computer-calculated mean was used to define QRSd, manual assessment demonstrated 97 and 83% concordance at categorizing QRSd as < and >or=120 ms, respectively. Using the computer-calculated maximal QRSd, manual assessment demonstrated 83% concordance when QRSd was <120 ms and 19% concordance when QRSd was >or=120 ms. The six-precordial lead format demonstrated significantly less intra and inter-observer variabilities than the 12-lead, but this did not improve concordance rates. Manual QRSd assessments demonstrate significant variability, and concordance with computer-calculated measurement depends on whether QRSd is defined as the mean or maximal value. Consensus is required both on the most appropriate definition of QRSd and its measurement.

  20. Magnetocardiography measurements with 4He vector optically pumped magnetometers at room temperature

    NASA Astrophysics Data System (ADS)

    Morales, S.; Corsi, M. C.; Fourcault, W.; Bertrand, F.; Cauffet, G.; Gobbo, C.; Alcouffe, F.; Lenouvel, F.; Le Prado, M.; Berger, F.; Vanzetto, G.; Labyt, E.

    2017-09-01

    In this paper, we present a proof of concept study which demonstrates for the first time the possibility of recording magnetocardiography (MCG) signals with 4He vector optically pumped magnetometers (OPM) operated in a gradiometer mode. Resulting from a compromise between sensitivity, size and operability in a clinical environment, the developed magnetometers are based on the parametric resonance of helium in a zero magnetic field. Sensors are operated at room temperature and provide a tri-axis vector measurement of the magnetic field. Measured sensitivity is around 210 f T (√Hz)-1 in the bandwidth (2 Hz; 300 Hz). MCG signals from a phantom and two healthy subjects are successfully recorded. Human MCG data obtained with the OPMs are compared to reference electrocardiogram recordings: similar heart rates, shapes of the main patterns of the cardiac cycle (P/T waves, QRS complex) and QRS widths are obtained with both techniques.

  1. Learning about Turner Syndrome

    MedlinePlus

    ... heart murmur, sometimes associated with narrowing of the aorta (blood vessel exiting the heart). A tendency to ... with a heart murmur or narrowing of the aorta may need surgery to correct the problem. A ...

  2. Lacosamide-Induced Recurrent Ventricular Tachycardia in the Acute Care Setting.

    PubMed

    Berei, Theodore J; Lillyblad, Matthew P; Almquist, Adrian K

    2018-04-01

    Lacosamide is a new-generation antiepileptic drug (AED) most commonly used adjunctively in the setting of partial-onset seizures refractory to traditional therapy. We describe the first case report, to our knowledge, of a patient who developed recurrent, sustained ventricular tachycardia with multiple administrations of lacosamide in an acute setting. A 70-year-old woman with a history significant for valvular heart disease was admitted to the inpatient cardiology service for worsening heart failure. On hospital day 7, she received a bioprosthetic aortic valve. Prior to surgery and immediately after, the patient's electrocardiogram (ECG) was normal. After developing multiple generalized tonic-clonic seizures refractory to levetiracetam, fosphenytoin, and valproic acid, the decision was made to initiate lacosamide. Two hours following the second lacosamide dose, the patient developed a wide complex QRS that transitioned into sustained ventricular tachycardia requiring electrical cardioversion. Sustained ventricular tachycardia occurred again, just hours after the third dose of lacosamide was given. Following cessation of lacosamide, the patient's QRS interval normalized and has since had no documented episodes of ventricular tachycardia. Clinicians should be aware of the potential for life-threatening rhythmic disturbances in patients initiated on lacosamide and the need for vigilant ECG, electrolyte, and drug-drug monitoring.

  3. Combined heart-kidney transplantation after total artificial heart insertion.

    PubMed

    Ruzza, A; Czer, L S C; Ihnken, K A; Sasevich, M; Trento, A; Ramzy, D; Esmailian, F; Moriguchi, J; Kobashigawa, J; Arabia, F

    2015-01-01

    We present the first single-center report of 2 consecutive cases of combined heart and kidney transplantation after insertion of a total artificial heart (TAH). Both patients had advanced heart failure and developed dialysis-dependent renal failure after implantation of the TAH. The 2 patients underwent successful heart and kidney transplantation, with restoration of normal heart and kidney function. On the basis of this limited experience, we consider TAH a safe and feasible option for bridging carefully selected patients with heart and kidney failure to combined heart and kidney transplantation. Recent FDA approval of the Freedom driver may allow outpatient management at substantial cost savings. The TAH, by virtue of its capability of providing pulsatile flow at 6 to 10 L/min, may be the mechanical circulatory support device most likely to recover patients with marginal renal function and advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Assessing the Utility of Compound Trait Estimates of Narrow Personality Traits.

    PubMed

    Credé, Marcus; Harms, Peter D; Blacksmith, Nikki; Wood, Dustin

    2016-01-01

    It has been argued that approximations of narrow traits can be made through linear combinations of broad traits such as the Big Five personality traits. Indeed, Hough and Ones ( 2001 ) used a qualitative analysis of scale content to arrive at a taxonomy of how Big Five traits might be combined to approximate various narrow traits. However, the utility of such compound trait approximations has yet to be established beyond specific cases such as integrity and customer service orientation. Using data from the Eugene-Springfield Community Sample (Goldberg, 2008 ), we explore the ability of linear composites of scores on Big Five traits to approximate scores on 127 narrow trait measures from 5 well-known non-Big-Five omnibus measures of personality. Our findings indicate that individuals' standing on more than 30 narrow traits can be well estimated from 3 different types of linear composites of scores on Big Five traits without a substantial sacrifice in criterion validity. We discuss theoretical accounts for why such relationships exist as well as the theoretical and practical implications of these findings for researchers and practitioners.

  5. Grassy Narrows Reserve: Mercury Pollution, Social Disruption, and Natural Resources: A Question of Autonomy.

    ERIC Educational Resources Information Center

    Vecsey, Christopher

    1987-01-01

    Presents chronological socio-economic account of Grassy Narrows Reserve, focusing on the 1962-1970 mercury pollution that poisoned the reserve's river system and on resulting negotiations between the Ojibway people of Grassy Narrows, the government, and the polluting company. Examines the question of Grassy Narrows people gaining autonomy over the…

  6. Canine left ventricle electromechanical behavior under different pacing modes.

    PubMed

    Vo Thang, Thanh-Thuy; Thibault, Bernard; Finnerty, Vincent; Pelletier-Galarneau, Matthieu; Khairy, Paul; Grégoire, Jean; Harel, François

    2012-10-01

    Cardiac resynchronization therapy may improve survival and quality of life in patients suffering from heart failure with left ventricular (LV) contraction dyssynchrony. While several studies have investigated electrical or mechanical determinants of synchronous contraction, few have focused on activation contraction coupling at a macroscopic level. The objective of the study was to characterize LV electromechanical behavior and response to pacing in a heart failure model. We analyzed data from 3D electroanatomic non-contact mapping and blood pool SPECT for 12 dogs with right ventricular (RV) tachycardia pacing-induced dilated cardiomyopathy. Surfaces generated by the two modalities were registered. Electrical signals were analyzed, and endocardial wall displacement curves were portrayed. Rapid pacing decreased the mean LV ejection fraction (LVEF) to 20.9 % and prolonged the QRS duration to 79 ± 10 ms (normal range: 40-50 ms). QRS duration remained unchanged with biventricular pacing (88.5 ms), while single site pacing further prolonged the QRS duration (113.3 ms for RV pacing and 111.6 ms for LV pacing). No trend was observed in LV systolic function. Activation duration time was significantly increased with all pacing modes compared to baseline. Finally, electromechanical delay, as defined by the delay between electrical activation and mechanical response, was increased by single site pacing (172.9 ms for RV pacing and 174.6 ms for LV pacing) but not by biventricular pacing (162.4 ms). Combined temporal and spatial coregistration electroanatomic maps and baseline gated blood pool SPECT imaging allowed us to quantify activation duration time, electromechanical delay, and LVEF for different pacing modes. Even if pacing modes did not significantly modify LVEF or activation duration, they produced alterations in electromechanical delay, with biventricular pacing significantly decreasing the electromechanical delay as measured by surface tracings and endocardial

  7. Can Functional Cardiac Age be Predicted from ECG in a Normal Healthy Population

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd; Starc, Vito; Leban, Manja; Sinigoj, Petra; Vrhovec, Milos

    2011-01-01

    In a normal healthy population, we desired to determine the most age-dependent conventional and advanced ECG parameters. We hypothesized that changes in several ECG parameters might correlate with age and together reliably characterize the functional age of the heart. Methods: An initial study population of 313 apparently healthy subjects was ultimately reduced to 148 subjects (74 men, 84 women, in the range from 10 to 75 years of age) after exclusion criteria. In all subjects, ECG recordings (resting 5-minute 12-lead high frequency ECG) were evaluated via custom software programs to calculate up to 85 different conventional and advanced ECG parameters including beat-to-beat QT and RR variability, waveform complexity, and signal-averaged, high-frequency and spatial/spatiotemporal ECG parameters. The prediction of functional age was evaluated by multiple linear regression analysis using the best 5 univariate predictors. Results: Ignoring what were ultimately small differences between males and females, the functional age was found to be predicted (R2= 0.69, P < 0.001) from a linear combination of 5 independent variables: QRS elevation in the frontal plane (p<0.001), a new repolarization parameter QTcorr (p<0.001), mean high frequency QRS amplitude (p=0.009), the variability parameter % VLF of RRV (p=0.021) and the P-wave width (p=0.10). Here, QTcorr represents the correlation between the calculated QT and the measured QT signal. Conclusions: In apparently healthy subjects with normal conventional ECGs, functional cardiac age can be estimated by multiple linear regression analysis of mostly advanced ECG results. Because some parameters in the regression formula, such as QTcorr, high frequency QRS amplitude and P-wave width also change with disease in the same direction as with increased age, increased functional age of the heart may reflect subtle age-related pathologies in cardiac electrical function that are usually hidden on conventional ECG.

  8. Einstein-Podolsky-Rosen Entanglement of Narrow-Band Photons from Cold Atoms.

    PubMed

    Lee, Jong-Chan; Park, Kwang-Kyoon; Zhao, Tian-Ming; Kim, Yoon-Ho

    2016-12-16

    Einstein-Podolsky-Rosen (EPR) entanglement introduced in 1935 deals with two particles that are entangled in their positions and momenta. Here we report the first experimental demonstration of EPR position-momentum entanglement of narrow-band photon pairs generated from cold atoms. By using two-photon quantum ghost imaging and ghost interference, we demonstrate explicitly that the narrow-band photon pairs violate the separability criterion, confirming EPR entanglement. We further demonstrate continuous variable EPR steering for positions and momenta of the two photons. Our new source of EPR-entangled narrow-band photons is expected to play an essential role in spatially multiplexed quantum information processing, such as, storage of quantum correlated images, quantum interface involving hyperentangled photons, etc.

  9. Einstein-Podolsky-Rosen Entanglement of Narrow-Band Photons from Cold Atoms

    NASA Astrophysics Data System (ADS)

    Lee, Jong-Chan; Park, Kwang-Kyoon; Zhao, Tian-Ming; Kim, Yoon-Ho

    2016-12-01

    Einstein-Podolsky-Rosen (EPR) entanglement introduced in 1935 deals with two particles that are entangled in their positions and momenta. Here we report the first experimental demonstration of EPR position-momentum entanglement of narrow-band photon pairs generated from cold atoms. By using two-photon quantum ghost imaging and ghost interference, we demonstrate explicitly that the narrow-band photon pairs violate the separability criterion, confirming EPR entanglement. We further demonstrate continuous variable EPR steering for positions and momenta of the two photons. Our new source of EPR-entangled narrow-band photons is expected to play an essential role in spatially multiplexed quantum information processing, such as, storage of quantum correlated images, quantum interface involving hyperentangled photons, etc.

  10. Experimental study on occupant evacuation in narrow seat aisle

    NASA Astrophysics Data System (ADS)

    Huang, Shenshi; Lu, Shouxiang; Lo, Siuming; Li, Changhai; Guo, Yafei

    2018-07-01

    Narrow seat aisle is an important area in the train car interior due to the large passenger population, however evacuation therein has not gained enough concerns. In this experimental study, the occupant evacuation of the narrow seat aisle area is investigated, with the aisle width of 0.4-0.6 m and the evacuation direction of forward and backward. The evacuation behaviors are analyzed based on the video record, and the discussion is carried out in the aspect of evacuation time, crowdedness, evacuation order, and aisle conflicts. The result shows that with the increasing aisle width, total evacuation time and the average specific evacuation rate decrease. The aisle is crowded for some time, with a large linear occupant densities. The evacuation order of each occupant is mainly related to the seat position. Moreover, it is found that the aisle conflicts can be well described by Burstedde's model. This study gives a useful benchmark for evacuation simulation of narrow seat aisle, and provides reference to safety design of seat area in train cars.

  11. Comparison of standard and Lewis ECG in detection of atrioventricular dissociation in patients with wide QRS tachycardia.

    PubMed

    Aksu, Uğur; Kalkan, Kamuran; Gülcü, Oktay; Topcu, Selim; Sevimli, Serdar; Aksakal, Enbiya; Ipek, Emrah; Açıkel, Mahmut; Tanboğa, Ibrahim Halil

    2016-12-15

    The atrioventricular (AV) dissociation, which is frequently used in differential diagnosis of wide QRS complex tachycardia (WQCT), is the most specific finding of ventricular tachycardia (VT) with lower sensitivity. Herein, we aimed to show the importance of Lewis lead ECG records to detect 'visible p waves' during WQCT. A total of 21 consecutive patients who underwent electrophysiologic study (EPS) were included in the study. During EPS, by using a quadripolar diagnostic catheter directed to the right ventricular apex, a fixed stimulus was given and the ventriculoatrial (VA) Wenkebach point was found, and a VT was simulated by a RV apical stimulus at 300ms. The standard and Lewis lead ECG records were taken during this procedure. We detected 'visible p waves' in 7 (33.3%) and 14 (66.7%) patients in the standard and Lewis lead ECG groups, respectively. In terms of the 'visible p waves', there was a statistically significant difference between groups (p=0.022). The sensitivity of standard and Lewis lead ECG in determination of the visible p waves was 33.3% and 66.7%, respectively. The Lewis lead ECG can be more informative about AV dissociation than the standard 12 lead ECG. As a result, we could suggest the assessment of the Lewis lead ECG recording in addition to the standard 12 lead ECG in differential diagnosis of VT in patients with WQCT. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Healthy Body, Happy Heart: Improve Your Heart Health

    MedlinePlus

    ... November 2017 Print this issue Healthy Body, Happy Heart Improve Your Heart Health En español Send us your comments Every moment of the day, your heart is pumping blood throughout your body. In silent ...

  13. Regression equations for calculation of z scores for echocardiographic measurements of left heart structures in healthy Han Chinese children.

    PubMed

    Wang, Shan-Shan; Hong, Wen-Jing; Zhang, Yu-Qi; Chen, Shu-Bao; Huang, Guo-Ying; Zhang, Hong-Yan; Chen, Li-Jun; Wu, Lan-Ping; Shen, Rong; Liu, Yi-Qing; Zhu, Jun-Xue

    2018-06-01

    Clinical decision making in children with heart disease relies on detailed measurements of cardiac structures using two-dimensional and M-mode echocardiography. However, no echocardiographic reference values are available for the Chinese children. We aimed to establish z-score regression equations for left heart structures in a population-based cohort of healthy Chinese Han children. Echocardiography was performed in 545 children with a normal heart. The dimensions of the aortic valve annulus (AVA), aortic sinuses of Valsalva (ASV), sinotubular junction (STJ), ascending aorta (AAO), left atrium (LA), mitral valve annulus (MVA), interventricular septal end-diastolic thickness (IVSd), interventricular septal end-systolic thickness (IVSs), left ventricular end-diastolic diameter (LVIDd), left ventricular end-systolic diameter (LVIDs), left ventricular posterior wall end-diastolic thickness (LVPWd), left ventricular posterior wall end-systolic thickness (LVPWs) were measured. Regression analyses were conducted to relate the measurements of left heart structures to body surface area (BSA). Left ventricular ejection fraction (LVEF) and left ventricular fractional shortening (LVFS) were calculated. Several models were used, and the adjusted R2 values were compared for each model. AVA, ASV, STJ, AAO, LA, MVA, IVSd, IVSs, LVIDd, LVIDs, LVPWd, and LVPWs had a cubic relationship with BSA. LVEF and LVFS fell within a narrow range. Our results provide reference values for z scores and regression equations for left heart structures in Han Chinese children. These data may help make a quick and accurate judgment of the routine clinical measurement of left heart structures in children with heart disease. © 2018 Wiley Periodicals, Inc.

  14. Participation in Heart-Healthy Behaviors: A Secondary Analysis of the American Heart Association Go Red Heart Match Data.

    PubMed

    Arslanian-Engoren, Cynthia; Eastwood, Jo-Ann; De Jong, Marla J; Berra, Kathy

    2015-01-01

    The American Heart Association created Go Red Heart Match, a free and secure online program that enables women to connect with each other to fight heart disease either personally or as a caregiver for someone with heart disease. Through these connections, participants have an opportunity to develop a personal, private, and supportive relationship with other women; share common experiences; and motivate and encourage each other to follow a heart-healthy lifestyle. The aims of this study were to describe the demographic characteristics of the Go Red Heart Match responders and to determine whether participation in the program prompted participants to engage in heart-healthy behaviors. A secondary analysis of data collected as part of a needs assessment survey from the American Heart Association Go Red Heart Match was conducted. A total of 117 (35%) of the 334 invited women completed the survey. Most responders were female, married, and college educated. A total of 105 (90%) responders were diagnosed with a type of heart disease or stroke and 77 (73%) responders had undergone treatment. As a result of participating in the program, 75% of the responders reported the following improvements in heart-healthy behaviors: eating a more heart-healthy diet (54%), exercising more frequently (53%), losing weight (47%), and quitting smoking (10%). Responders who had a diagnosis of heart attack (n = 48) were more likely (P = .003) to quit smoking than were those with other diagnoses (n = 69). Notably, 48% of responders reported encouraging someone else in their life to speak to their doctor about their risk for heart disease. Most women who participated in Heart Match reported engaging in new heart-healthy behaviors. The findings support expanding the existing program in a more diverse population as a potentially important way to reach women and encourage cardiovascular disease risk reduction for those with heart disease and stroke.

  15. Role of echocardiography before cardiac resynchronization therapy: new advances and current developments.

    PubMed

    Marechaux, Sylvestre; Menet, Aymeric; Guyomar, Yves; Ennezat, Pierre-Vladimir; Guerbaai, Raphaëlle Ashley; Graux, Pierre; Tribouilloy, Christophe

    2016-11-01

    The role of echocardiography in improving the selection of patients who will benefit from cardiac resynchronization therapy (CRT) remains a source of debate. Although previous landmark reports have demonstrated a link between mechanical dyssynchrony, assessed by delays between left ventricle (LV) walls and response to CRT, the predictive value of these findings has not yet been confirmed in multicenter trials. Indeed, recent studies demonstrated that the classical assessment of LV mechanical dyssynchrony using delay between walls by echocardiography depends not only on LV electrical activation delay (electrical dyssynchrony), but also on abnormalities in regional contractility of the LV and/or loading conditions, which do not represent an appropriate target for CRT. Recent reports highlighted the value of new indices of electromechanical dyssynchrony obtained by echocardiography, to predict LV response and outcome after CRT including septal flash, left bundle branch block-typical pattern by longitudinal strain, apical rocking, septal strain patterns, and systolic stretch index. This was achieved using a mechanistic approach, based on the contractile consequences of electrical dyssynchrony. These indices are rarely found in patients with narrow QRS (<120 ms), whereas their frequency rises in patients with an increase in QRS duration (>120 ms). Theses indices should improve candidate selection for CRT in clinical practice, especially for patients in whom the benefit of CRT remains uncertain, for example, patients with intermediate QRS width (120-150 ms). © 2016, Wiley Periodicals, Inc.

  16. Enlarged Heart

    MedlinePlus

    ... rheumatic fever, a heart defect, infections (infectious endocarditis), connective tissue disorders, certain medications or radiation treatments for cancer, your heart may enlarge. Disease of the heart ...

  17. About Heart Attacks

    MedlinePlus

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More About Heart Attacks Updated:Jan 11,2018 A heart attack is ... coronary artery damage leads to a heart attack . Heart Attack Questions and Answers What is a heart attack? ...

  18. Rapid water transportation through narrow one-dimensional channels by restricted hydrogen bonds.

    PubMed

    Ohba, Tomonori; Kaneko, Katsumi; Endo, Morinobu; Hata, Kenji; Kanoh, Hirofumi

    2013-01-29

    Water plays an important role in controlling chemical reactions and bioactivities. For example, water transportation through water channels in a biomembrane is a key factor in bioactivities. However, molecular-level mechanisms of water transportation are as yet unknown. Here, we investigate water transportation through narrow and wide one-dimensional (1D) channels on the basis of water-vapor adsorption rates and those determined by molecular dynamics simulations. We observed that water in narrow 1D channels was transported 3-5 times faster than that in wide 1D channels, although the narrow 1D channels provide fewer free nanospaces for water transportation. This rapid transportation is attributed to the formation of fewer hydrogen bonds between water molecules adsorbed in narrow 1D channels. The water-transportation mechanism provides the possibility of rapid communication through 1D channels and will be useful in controlling reactions and activities in water systems.

  19. Too Narrow a Vision

    ERIC Educational Resources Information Center

    Crowther, Jim

    2011-01-01

    "Meeting the needs of the learner is at the heart of all our proposals", is the claim in the ministerial foreword to "Putting Learners at the Centre", the document in which recent pre-legislative proposals for reforming the post-16 education sector are set out by the Scottish Government. Such a grand claim warrants scepticism.…

  20. Women's Heart Disease: Join the Heart Truth Community

    MedlinePlus

    ... this page please turn JavaScript on. Feature: Women's Heart Disease Join The Heart Truth Community Past Issues / Winter 2014 Table of Contents National Symbol The centerpiece of The Heart Truth ® is The Red Dress ® which was introduced ...

  1. CT demonstration of pharyngeal narrowing in adult obstructive sleep apnea

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bohlman, M.E.; Haponik, E.F.; Smith, P.L.

    Sleep apnea is a major cause of daytime hypersomnolence. Among the proposed etiologies, focal obstruction of the airways at the level of the pharynx has been suggested but not proven. Using computed tomography, the cross-sectional area of the airway can be readily assessed. Thirty-three adults with clinically proven sleep apnea and 12 normal adults underwent systematic computed tomography of the neck. Significant airway narrowing was demonstrated in all the patients with obstructive sleep apnea, whereas no such narrowing was seen in the controls. In 11, the narrowing was at a single level, whereas in 22 patients two or more levelsmore » were affected. This study has shown that a structurally abnormal airway may serve as an anatomic substrate for the development of sleep apnea. On the basis of this evidence, uvulopalatopharyngoplasty has been performed in two patients with relief of symptoms in one.« less

  2. Pressure Fluctuation Characteristics of Narrow Gauge Train Running Through Tunnel

    NASA Astrophysics Data System (ADS)

    Suzuki, Masahiro; Sakuma, Yutaka

    Pressure fluctuations on the sides of narrow (1067 mm) gauge trains running in tunnels are measured for the first time to investigate the aerodynamic force acting on the trains. The present measurements are compared with earlier measurements obtained with the Shinkansen trains. The results are as follows: (1) The aerodynamic force, which stems from pressure fluctuations on the sides of cars, puts the energy into the vibration of the car body running through a tunnel. (2) While the pressure fluctuations appear only on one of the two sides of the trains running in double-track tunnels, the fluctuations in opposite phase on both sides in single-track tunnels. (3) The on-track test data of the narrow gauge trains show the same tendency as those of the Shinkansen trains, although it is suggested that the pressure fluctuations develop faster along the narrow gauge trains than the Shinkansen trains.

  3. Heart to Heart Art: Empowering Homeless Children and Youth

    ERIC Educational Resources Information Center

    Shepard, Jerri; Booth, Deborah

    2009-01-01

    This article describes Heart to Heart Art, an after-school program developed for homeless children and youth at the YWCA in Spokane, Washington. Pre-service teacher candidates from a local university create meaningful activities that engage homeless students in visual art, music, drama, cooking, and community service. Heart to Heart Art was…

  4. Computational Modeling of Blood Flow and Valve Dynamics in Hearts with Hypertrophic Cardiomyopathy

    NASA Astrophysics Data System (ADS)

    Zheng, Xudong; Mittal, Rajat; Abraham, Theodore; Pinheiro, Aurelio

    2010-11-01

    Hypertrophic Cardiomyopathy (HCM) is a cardiovascular disease manifested by the thickening of the ventricular wall and often leads to a partial obstruction to the blood flow out of the left ventricle. HCM is recognized as one of the most common causes of sudden cardiac death in athletes. In a heart with HCM, the hypertrophy usually narrows the blood flow pathway to the aorta and produces a low pressure zone between the mitral valve and the hypertrophy during systole. This low pressure can suck the mitral valve leaflet back and completely block the blood flow into the aorta. In the current study, a sharp interface immersed boundary method flow solver is employed to study the hemodynamics and valve dynamics inside a heart with HCM. The three-dimensional motion and configuration of the left ventricle including mitral valve leaflets and aortic valves are reconstructed based on echo-cardio data sets. The mechanisms of aortic obstruction associated with HCM are investigated. The long term objective of this study is to develop a computational tool to aid in the assessment and surgical management of HCM.

  5. Narrowing the Achievement Gap: A Case Study of an Urban School

    ERIC Educational Resources Information Center

    Lugo, Rosalinda

    2010-01-01

    The goal of this case study was to identify the cultural norms, practices, and programs of an urban school that narrowed the achievement gap. The reason for identifying these factors in a successful school was to add to the body of literature regarding the achievement gap and what a struggling school was able to do to narrow the gap. This case…

  6. Heart Health: Learn the Truth About Your Heart

    MedlinePlus

    ... Bar Home Current Issue Past Issues Cover Story Heart Health Learn the Truth About Your Heart Past Issues / Winter 2009 Table of Contents For ... turn Javascript on. Photo: iStock February is American Heart Month. Now is the time to make sure ...

  7. Sokolow-Lyon voltage is suitable for monitoring improvement in cardiac function and prognosis of patients with idiopathic dilated cardiomyopathy.

    PubMed

    Fukaya, Kenji; Takeshita, Kyosuke; Okumura, Takahiro; Hiraiwa, Hiroaki; Aoki, Soichiro; Ichii, Takeo; Sugiura, Yuki; Kitagawa, Katsuhide; Kondo, Toru; Watanabe, Naoki; Kano, Naoaki; Furusawa, Kenji; Sawamura, Akinori; Morimoto, Ryota; Bando, Yasuko; Murohara, Toyoaki

    2017-09-01

    The clinical significance of electrocardiogram in the assessment of patients with idiopathic dilated cardiomyopathy (IDCM) is currently unknown. The aim of this study was to determine the feasibility of recording serial changes in Sokolow-Lyon voltage (∆%QRS-voltage) in one year to estimate left ventricular reverse remodeling (LVRR) and predict a prognosis of IDCM patients under tailored medical therapy. Sixty-eight consecutive patients with mild symptoms (52.1 ± 13 years old; 69% men; NYHA I/II/III/IV; 33/29/6/0) underwent electrocardiography and echocardiography at baseline and 12 month follow-up (follow-up period: 3.9 years). LVRR was observed in 30 patients (44.1%). The ∆%QRS-voltage was significantly lower in the LVRR group (LVRR; -26.9%, non-LVRR: -9.2%, p < .001). Univariate analysis showed that ∆%QRS-voltage correlated with ∆%LV end-diastolic diameter (r = .634, p < .001), and with ∆%LV ejection fraction and ∆%LV mass index (r = -.412, p < .001; r = .429, p < .001 respectively). Using receiver operating characteristic curve analysis for the estimation of LVRR, ∆%QRS of -14.7% showed optimal sensitivity (63.2%) and specificity (83.3%) (AUC = 0.775, p < .001). The composite endpoints of cardiac death (n = 0), hospitalization for advanced heart failure (n = 11) and fatal arrhythmia (n = 2) were observed in 13 patients during the follow-up period. Kaplan-Meier analysis showed significantly higher event-free rate in patients of the low ∆%QRS-voltage group (<-14.7%) (83%) than those of the high group (66%, p = .022). The present study showed that decrease in Sokolow-Lyon voltage is associated with improvement in cardiac function and favorable prognosis in IDCM patients on medical therapy, suggesting that this index is a feasible marker for response to treatment of IDCM. © 2017 Wiley Periodicals, Inc.

  8. Ischemia episode detection in ECG using kernel density estimation, support vector machine and feature selection

    PubMed Central

    2012-01-01

    Background Myocardial ischemia can be developed into more serious diseases. Early Detection of the ischemic syndrome in electrocardiogram (ECG) more accurately and automatically can prevent it from developing into a catastrophic disease. To this end, we propose a new method, which employs wavelets and simple feature selection. Methods For training and testing, the European ST-T database is used, which is comprised of 367 ischemic ST episodes in 90 records. We first remove baseline wandering, and detect time positions of QRS complexes by a method based on the discrete wavelet transform. Next, for each heart beat, we extract three features which can be used for differentiating ST episodes from normal: 1) the area between QRS offset and T-peak points, 2) the normalized and signed sum from QRS offset to effective zero voltage point, and 3) the slope from QRS onset to offset point. We average the feature values for successive five beats to reduce effects of outliers. Finally we apply classifiers to those features. Results We evaluated the algorithm by kernel density estimation (KDE) and support vector machine (SVM) methods. Sensitivity and specificity for KDE were 0.939 and 0.912, respectively. The KDE classifier detects 349 ischemic ST episodes out of total 367 ST episodes. Sensitivity and specificity of SVM were 0.941 and 0.923, respectively. The SVM classifier detects 355 ischemic ST episodes. Conclusions We proposed a new method for detecting ischemia in ECG. It contains signal processing techniques of removing baseline wandering and detecting time positions of QRS complexes by discrete wavelet transform, and feature extraction from morphology of ECG waveforms explicitly. It was shown that the number of selected features were sufficient to discriminate ischemic ST episodes from the normal ones. We also showed how the proposed KDE classifier can automatically select kernel bandwidths, meaning that the algorithm does not require any numerical values of the parameters

  9. Usefulness of Derived Frank Lead Parameters in Screening for Coronary Artery Disease and Cardiomyopathy

    NASA Technical Reports Server (NTRS)

    DePalma, J. L.; Schlegel, T. T.; Arenare, B.; Greco, E. C.; Starc, V.; Rahman, M. A.; Delgado, R.

    2007-01-01

    We investigated the accuracy of several known as well as newly-introduced derived Frank-lead ECG parameters in differentiating healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. The following derived Frank lead parameters were studied for their accuracy in detecting CAD and CM: the spatial ventricular gradient (VG), including its beat-to-beat coefficient of variability (VG CV); the spatial mean QRS (SM-QRS) and T-waves (SM-T) and their beat-to-beat coefficients of variability; the spatial ventricular activation time (VAT); the mean and maximum spatial QRS-T angles; and standard late potentials parameters (RMS40, fQRSD and LAS). Several of these parameters were accurate in discriminating between the control group and both diseased groups at p less than 0.0001. For example the fQRSD, VG CV, mean spatial QRS-T angle and VG minus SM-QRS (which is similar to the SM-T) had retrospective areas under the ROC curve of 0.78, 0.78, 0.80, and 0.84 (CAD vs. controls) and 0.93, 0.88, 0.98 and 0.99 (CM vs. controls), respectively. The single most effective parameter in discriminating between the CAD and CM groups was the spatial VAT (44 plus or minus 5.8 vs. 53 plus or minus 9.9 ms, p less than 0.0001), with an area under the ROC curve of 0.80. Since subsequent prospective analyses using new groups of patients and healthy subjects have yielded only slightly less accurate results, we conclude that derived Frank-lead parameters show great promise for potentially contributing to the development of a rapid and inexpensive resting ECG-based screening test for heart disease.

  10. Heart transplantation in adult congenital heart disease.

    PubMed

    Burchill, Luke J

    2016-12-01

    Heart failure (HF) in adult congenital heart disease (ACHD) is vastly different to that observed in acquired heart disease. Unlike acquired HF in which pharmacological strategies are the cornerstone for protecting and improving ventricular function, ACHD-related HF relies heavily upon structural and other interventions to achieve these aims. patients with ACHD constitute a small percentage of the total adult heart transplant population (∼3%), although the number of ACHD heart transplant recipients is growing rapidly with a 40% increase over the last two decades. The worldwide experience to date has confirmed heart transplantation as an effective life-extending treatment option in carefully selected patients with ACHD with end-stage cardiac disease. Opportunities for improving outcomes in patients with ACHD-related HF include (i) earlier recognition and referral to centres with combined expertise in ACHD and HF, (ii) increased awareness of arrhythmia and sudden cardiac death risk in this population, (iii) greater collaboration between HF and ACHD specialists at the time of heart transplant assessment, (iv) expert surgical planning to reduce ischaemic time and bleeding risk at the time of transplant, (v) tailored immunosuppression in the post-transplant period and (vi) development and validation of ACHD-specific risk scores to predict mortality and guide patient selection. The purpose of this article is to review current approaches to diagnosing and treating advanced HF in patients with ACHD including indications, contraindications and clinical outcomes after heart transplantation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Heart attack

    MedlinePlus

    ... infarction; Non-ST - elevation myocardial infarction; NSTEMI; CAD - heart attack; Coronary artery disease - heart attack ... made up of cholesterol and other cells. A heart attack may occur when: A tear in the ...

  12. [Influence of the duration of recording in the reproducibility of the signal averaged electrocardiogram].

    PubMed

    Copie, X; Blankoff, I; Hnatkova, K; Fei, L; Camm, A J; Malik, M

    1996-06-01

    The authors studied the possibility of improving the reproducibility of the signal averaged ECG by increasing the number of averaged QRS complexes. One hundred patients were included in the study. In each cases, 400 QRS complexes were recorded on twice, consecutively, in strictly identical conditions. During each recording, the total duration of the amplified and averaged QRS complex (tQRS), the duration of the terminal signal below 40 microV (LAS) and the root mean square of the amplitude of the last 40 ms (RMS) were determined for 100, 200, 300 and 400 recorded QRS complexes. The presence of late potentials was defined as the positivity of two of the following criteria: tQRS > 114 ms, LAS > 38 ms, RMS < 20 microV. The number of contradictory diagnostic conclusions between two successive recordings of the same duration decreased progressively with the number of averaged QRS complexes: 10 for 100 QRS, 10 for 200 QRS, 9 for 300 QRS and 6 for 400 QRS complexes, but this improvement was not statistically significant. The absolute differences of tQRS and RMS between two successive recordings of the same duration were statistically different for the four durations of recording (p = 0.05) and there was a tendency towards statistical significance for LAS (p = 0.09). The best quantitative reproducibility of the 3 parameters was obtained with the recording of 300 QRS complexes. In conclusion, the reproducibility of the signal averaged ECG is improved when the number of average QRS complexes is increased. The authors' results suggests that reproducibility this is optimal with the amplification and averaging of 300 QRS complexes.

  13. High prevalence of narrow angles among Chinese-American glaucoma and glaucoma suspect patients.

    PubMed

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data were collected for sex, age, race (self-declared), refraction (spherical equivalent), intraocular pressure, gonioscopy, and vertical cup-to-disk ratio. Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade < or = 2 in 3 or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the 2 groups did not differ in terms of sex, refraction, intraocular pressure, or cup-to-disk ratio (all, P > or = 0.071). In a multivariate model including age, sex, and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of sex or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed.

  14. Metabolic support for the heart: complementary therapy for heart failure?

    PubMed

    Heggermont, Ward A; Papageorgiou, Anna-Pia; Heymans, Stephane; van Bilsen, Marc

    2016-12-01

    The failing heart has an increased metabolic demand and at the same time suffers from impaired energy efficiency, which is a detrimental combination. Therefore, therapies targeting the energy-deprived failing heart and rewiring cardiac metabolism are of great potential, but are lacking in daily clinical practice. Metabolic impairment in heart failure patients has been well characterized for patients with reduced ejection fraction, and is coming of age in patients with 'preserved' ejection fraction. Targeting cardiomyocyte metabolism in heart failure could complement current heart failure treatments that do improve cardiovascular haemodynamics, but not the energetic status of the heart. In this review, we discuss the hallmarks of normal cardiac metabolism, typical metabolic disturbances in heart failure, and past and present therapeutic targets that impact on cardiac metabolism. © 2016 The Authors. European Journal of Heart Failure © 2016 European Society of Cardiology.

  15. Keeping the Edges Sharp I: Honing the Theory of Narrow Rings

    NASA Astrophysics Data System (ADS)

    Hamilton, Douglas P.; Rimlinger, Thomas; Hahn, Joseph M.

    2016-05-01

    Most of the rings that encircle Saturn, Uranus, and Neptune are very narrow structures with typical radial widths of just a few kilometers. Such extreme sharpness is surprising, as even slightly different orbital periods should allow ring particles to continually jostle one another in collisions that preserve angular momentum whileinexorably draining energy. Sharp edges should blur as rings spread in response to collisions and yet they do not. The generally accepted solution to this dilemma is to bracket each narrow ring with a pair of shepherding satellites that can pump energy back into the ring to replace that lost by collisions. But only a disappointing two of roughly twenty narrow rings actually have known attendant satellites. We present a compelling alternative in which the slight eccentricities and inclinations of narrow ringlets act as internal energy sources that can be tapped to prevent ring spreading. When unattended circular rings dissipate energy they must spread radially in order to preserve angular momentum. By contrast, eccentric or inclined rings have an extra degree of freedom that can be exploited to prevent radial spreading; energy is dissipated while keeping z-component of angular momentum, sqrt(a(1-e^2))cos(i), constant by simply decreasing the overall eccentricity (e) and/or inclination (i) of the entire ring. A real narrow ring moves inward as a unit, circularizes, and drops into the equatorial plane in a process that deters radial spreading for millions or billions of years. Using secular theory with dissipation (Zhang et al. 2013), we show that narrow rings are secular eigenstates in which ellipses are nested with pericenters almost, but not exactly aligned. The misalignment of pericenters is crucial in allowing energy dissipation to be shared evenly across the ring. We predict ring surface densities that are roughly constant across the ring's width, in contrast to profiles expected for shepherded rings. Rimlinger et al. (this meeting

  16. Simple, heart-smart substitutions

    MedlinePlus

    Coronary artery disease - heart smart substitutions; Atherosclerosis - heart smart substitutions; Cholesterol - heart smart substitutions; Coronary heart disease - heart smart substitutions; Healthy diet - heart ...

  17. Heart disease - resources

    MedlinePlus

    Resources - heart disease ... The following organizations are good resources for information on heart disease: American Heart Association -- www.heart.org Centers for Disease Control and Prevention -- www.cdc.gov/heartdisease

  18. Coronary heart disease

    MedlinePlus

    Heart disease, Coronary heart disease, Coronary artery disease; Arteriosclerotic heart disease; CHD; CAD ... buildup of plaque in the arteries to your heart. This may also be called hardening of the ...

  19. Application of narrow-band television to industrial and commercial communications

    NASA Technical Reports Server (NTRS)

    Embrey, B. C., Jr.; Southworth, G. R.

    1974-01-01

    The development of narrow-band systems for use in space systems is presented. Applications of the technology to future spacecraft requirements are discussed along with narrow-band television's influence in stimulating development within the industry. The transferral of the technology into industrial and commercial communications is described. Major areas included are: (1) medicine; (2) education; (3) remote sensing for traffic control; and (5) weather observation. Applications in data processing, image enhancement, and information retrieval are provided by the combination of the TV camera and the computer.

  20. Narrow-band filters for the lightning imager

    NASA Astrophysics Data System (ADS)

    Piegari, Angela; Di Sarcina, Ilaria; Grilli, Maria Luisa; Menchini, Francesca; Scaglione, Salvatore; Sytchkova, Anna; Zola, Danilo; Cuevas, Leticia P.

    2017-11-01

    The study of lightning phenomena will be carried out by a dedicated instrument, the lightning imager, that will make use of narrow-band transmission filters for separating the Oxygen emission lines in the clouds, from the background signal. The design, manufacturing and testing of these optical filters will be described here.

  1. Determinants of lens vault and association with narrow angles in patients from Singapore.

    PubMed

    Tan, Gavin S; He, Mingguang; Zhao, Wanting; Sakata, Lisandro M; Li, Jialiang; Nongpiur, Monisha E; Lavanya, Raghavan; Friedman, David S; Aung, Tin

    2012-07-01

    To describe the distribution and determinants of lens vault and to investigate the association of lens vault with narrow angles. Prospective cross-sectional study. Phakic subjects 50 years and older were evaluated at a primary healthcare clinic with gonioscopy, partial laser interferometry, and anterior segment optical coherence tomography (AS-OCT). Narrow angles were defined as posterior trabecular meshwork not visible for ≥2 quadrants on non-indentation gonioscopy. Lens vault was defined as the perpendicular distance between the anterior pole of the crystalline lens and the horizontal line joining the 2 scleral spurs on horizontal AS-OCT scans. Analysis of covariance, multivariate logistic regression, and area under the receiver operating characteristic curves (AUC) were performed. Of the 2047 subjects recruited, 582 were excluded because of poor image quality or inability to locate scleral spurs, leaving 1465 subjects for analysis. Eyes with narrow angles had greater lens vault compared to eyes with open angles (775.6 µm vs 386.5 µm, P < .0001). Women had significantly greater lens vault than men (497.28 µm vs 438.56 µm, P < .001), and lens vault increased significantly with age (P for trend <.001). Adjusted for age and sex, significant associations with greater lens vault were shorter axial length, shallower anterior chamber depth(ACD), higher intraocular pressure, and more hyperopic spherical equivalent (all P < .001). On multivariate analysis, subjects with lens vault >667.6 µm were more likely to have narrow angles (OR 2.201, 95% CI: 1.070-4.526) compared to those with lens vault ≤462.7 µm. The AUC for lens vault (0.816) and ACD (0.822) for detecting narrow angles were similar (P = .582). Lens vault was independently associated with narrow angles and may be useful in screening to detect eyes with narrow angles. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. High Prevalence of Narrow Angles among Chinese-American Glaucoma and Glaucoma Suspect Patients

    PubMed Central

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    Purpose To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Patients and Methods Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data was collected for gender, age, race (self-declared), refraction (spherical equivalent), intraocular pressure (IOP), gonioscopy and vertical cup-to-disk ratio (CDR). Results Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade ≤2 in three or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the two groups did not differ in terms of gender, refraction, IOP or CDR (all, P≥0.071). In a multivariate model including age, gender and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). Conclusions A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of gender or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed. PMID:19826385

  3. Neural activity underlying motor-action preparation and cognitive narrowing in approach-motivated goal states.

    PubMed

    Gable, Philip A; Threadgill, A Hunter; Adams, David L

    2016-02-01

    High-approach-motivated (pre-goal) positive affect states encourage tenacious goal pursuit and narrow cognitive scope. As such, high approach-motivated states likely enhance the neural correlates of motor-action preparation to aid in goal acquisition. These neural correlates may also relate to the cognitive narrowing associated with high approach-motivated states. In the present study, we investigated motor-action preparation during pre-goal and post-goal states using an index of beta suppression over the motor cortex. The results revealed that beta suppression was greatest in pre-goal positive states, suggesting that higher levels of motor-action preparation occur during high approach-motivated positive states. Furthermore, beta and alpha suppression in the high approach-motivated positive states predicted greater cognitive narrowing. These results suggest that approach-motivated pre-goal states engage the neural substrates of motor-action preparation and cognitive narrowing. Individual differences in motor-action preparation relate to the degree of cognitive narrowing.

  4. Electrocardiographic abnormalities and arrhythmic risk markers in adult patients with beta thalassemia major.

    PubMed

    Kolios, Marios; Korantzopoulos, Panagiotis; Vlahos, Antonios P; Kapsali, Eleni; Briasoulis, Evangelos; Goudevenos, John A

    2016-10-15

    There seems to be a significant arrhythmia burden in β-thalassemia major (TM) patients without overt cardiomyopathy. Apart from conventional electrocardiographic (ECG) and arrhythmic risk markers we studied novel markers of ventricular repolarization and autonomic imbalance both at rest and after exercise testing. We studied 47 adult TM patients without systolic heart failure and 47 age and sex-matched healthy control subjects. The median age of the studied population was 36 [32-43] years, 57% men. Baseline demographic and clinical characteristics were recorded while 12-lead electrocardiograms, 24-hour ECG Holter recordings, and treadmill exercise stress tests were analyzed. TM patients exhibited increased QTc intervals in both 12-lead ECG recordings and in 24-hour Holter recordings. In addition, they had increased indexes of ventricular repolarization heterogeneity such as QT dispersion, and T peak-to-end/QT ratios. Furthermore, TM patients had decreased indexes of heart rate variability while the heart rate recovery after exercise was significantly attenuated compared to controls. Also, they had increased P wave and QRS duration while the QRS fragmentation was very prevalent. Finally, premature atrial extrasystoles and paroxysmal atrial fibrillation episodes were more frequent in TM patients. TM patients with preserved left ventricular systolic function have several ECG abnormalities including alterations in ventricular depolarization and repolarization. Also, cardiac autonomic dysfunction is evident in 24-hour ECG monitoring as well as in the recovery phase after exercise testing. The prognostic value of specific arrhythmic risk indexes in this setting remains to be elucidated. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Heart regeneration.

    PubMed

    Breckwoldt, Kaja; Weinberger, Florian; Eschenhagen, Thomas

    2016-07-01

    Regenerating an injured heart holds great promise for millions of patients suffering from heart diseases. Since the human heart has very limited regenerative capacity, this is a challenging task. Numerous strategies aiming to improve heart function have been developed. In this review we focus on approaches intending to replace damaged heart muscle by new cardiomyocytes. Different strategies for the production of cardiomyocytes from human embryonic stem cells or human induced pluripotent stem cells, by direct reprogramming and induction of cardiomyocyte proliferation are discussed regarding their therapeutic potential and respective advantages and disadvantages. Furthermore, different methods for the transplantation of pluripotent stem cell-derived cardiomyocytes are described and their clinical perspectives are discussed. This article is part of a Special Issue entitled: Cardiomyocyte Biology: Integration of Developmental and Environmental Cues in the Heart edited by Marcus Schaub and Hughes Abriel. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Hypoplastic left heart syndrome

    MedlinePlus

    HLHS; Congenital heart - hypoplastic left heart; Cyanotic heart disease - hypoplastic left heart ... Hypoplastic left heart is a rare type of congenital heart disease. It is more common in males than in females. As ...

  7. Why Hart found narrow ecospheres--a minor science mystery solved.

    PubMed

    Levenson, Barton Paul

    2015-05-01

    To explain why two NASA computer simulation studies in the 1970s (Hart, 1978 , 1979 ) briefly rocked the subfield of astrobiology and SETI studies by showing very narrow habitable zones (HZs) for solar-type stars. Although other studies later supported wider HZs, it was never clear why the Hart simulations found the narrow limits they did. Investigation of the state of climate studies and radiative transfer models in the period 1960-1970 provides a likely explanation. Hart's findings were in line with earlier results, preventing him from noticing that his radiation model was inadequate.

  8. HEART OF MYTH – HEART OF SCIENCE Part I

    PubMed Central

    Bound Alberti, Fay

    2015-01-01

    This article explores the history and meanings of the heart and its diseases as aspects of the histories of science and emotion. Analyzing the twofold meanings of the heart as both bodily object and cultural symbol, it explores the reasons for the apparent conflict in meanings of the heart of science and the heart of emotion in Western medical culture since the 19th century. In Part I, a case study of the writer, economist, and philosopher Harriet Martineau is used to demonstrate and trace that conflict, while Part II highlights the manifold meanings of the heart both in the past and in the present. PMID:26167117

  9. Narrow band imaging combined with water immersion technique in the diagnosis of celiac disease.

    PubMed

    Valitutti, Francesco; Oliva, Salvatore; Iorfida, Donatella; Aloi, Marina; Gatti, Silvia; Trovato, Chiara Maria; Montuori, Monica; Tiberti, Antonio; Cucchiara, Salvatore; Di Nardo, Giovanni

    2014-12-01

    The "multiple-biopsy" approach both in duodenum and bulb is the best strategy to confirm the diagnosis of celiac disease; however, this increases the invasiveness of the procedure itself and is time-consuming. To evaluate the diagnostic yield of a single biopsy guided by narrow-band imaging combined with water immersion technique in paediatric patients. Prospective assessment of the diagnostic accuracy of narrow-band imaging/water immersion technique-driven biopsy approach versus standard protocol in suspected celiac disease. The experimental approach correctly diagnosed 35/40 children with celiac disease, with an overall diagnostic sensitivity of 87.5% (95% CI: 77.3-97.7). An altered pattern of narrow-band imaging/water immersion technique endoscopic visualization was significantly associated with villous atrophy at guided biopsy (Spearman Rho 0.637, p<0.001). Concordance of narrow-band imaging/water immersion technique endoscopic assessments was high between two operators (K: 0.884). The experimental protocol was highly timesaving compared to the standard protocol. An altered narrow-band imaging/water immersion technique pattern coupled with high anti-transglutaminase antibodies could allow a single guided biopsy to diagnose celiac disease. When no altered mucosal pattern is visible even by narrow-band imaging/water immersion technique, multiple bulbar and duodenal biopsies should be obtained. Copyright © 2014. Published by Elsevier Ltd.

  10. Women and Heart Disease: Sharing Advice from the Heart

    MedlinePlus

    ... page please turn JavaScript on. Feature: Women and Heart Disease Sharing Advice From The Heart Past Issues / Spring 2016 Table of Contents This ... inspired you to get involved in the American Heart Association's Go Red For Women movement and Red ...

  11. [Understanding heart failure].

    PubMed

    Boo, José Fernando Guadalajara

    2006-01-01

    Heart failure is a disease with several definitions. The term "heart failure" is used by has brougth about confusion in the terminology. For this reason, the value of the ejection fraction (< 0.40 or < 0.35) is used in most meganalyses on the treatment of heart failure, avoiding the term "heart failure" that is a confounding concept. In this paper we carefully analyze the meaning of contractility, ventricular function or performance, preload, afterload, heart failure, compensation mechanisms in heart failure, myocardial oxygen consumption, inadequate, adequate and inappropriate hypertrophy, systole, diastole, compliance, problems of relaxation, and diastolic dysfunction. Their definitions are supported by the original scientific descriptions in an attempt to clarify the concepts about ventricular function and heart failure and, in this way, use the same scientific language about the meaning of ventricular function, heart failure, and diastolic dysfunction.

  12. CDC Vital Signs: Heart Age - Is Your Heart Older Than You?

    MedlinePlus

    ... Digital Press Kit Read the MMWR Science Clips Heart Age Is Your Heart Older Than You? Language: ... that increase heart age. Problem US adults have hearts 7 years older than they should be. Though ...

  13. Looking through an adolescent literacy lens at the narrow view of reading.

    PubMed

    Ehren, Barbara J

    2009-04-01

    This commentary is a personal reaction to A. G. Kamhi's (2007) article on the "narrow view" of reading and his suggestion that this view be adopted as a way to address the reading problems of children and adolescents. In this article, I consider the narrow view of reading from an adolescent literacy perspective and discuss the practical implications of adopting this view in the schools. Discussion revolves around the complexities of reading comprehension, comprehension as a teachable set of complex processes, and the speech-language pathologist's role in reading comprehension. Although I acknowledge that the narrow view of reading may have merit, I opine that it may create more problems than it solves.

  14. Employment after heart transplantation among adults with congenital heart disease.

    PubMed

    Tumin, Dmitry; Chou, Helen; Hayes, Don; Tobias, Joseph D; Galantowicz, Mark; McConnell, Patrick I

    2017-12-01

    Adults with congenital heart disease may require heart transplantation for end-stage heart failure. Whereas heart transplantation potentially allows adults with congenital heart disease to resume their usual activities, employment outcomes in this population are unknown. Therefore, we investigated the prevalence and predictors of work participation after heart transplantation for congenital heart disease. Retrospective review of a prospective registry. United Network for Organ Sharing registry of transplant recipients in the United States. Adult recipients of first-time heart transplantation with a primary diagnosis of congenital heart disease, performed between 2004 and 2015. None. Employment status reported by transplant centers at required follow-up intervals up to 5 y posttransplant. Among 470 patients included in the analysis (mean follow-up: 5 ± 3 y), 127 (27%) worked after transplant, 69 (15%) died before beginning or returning to work, and 274 (58%) survived until censoring, but did not participate in paid work. Multivariable competing-risks regression analysis examined characteristics associated with posttransplant employment, accounting for mortality as a competing outcome. In descriptive and multivariable analysis, pretransplant work participation was associated with a greater likelihood of posttransplant employment, while the use of Medicaid insurance at the time of transplant was associated with a significantly lower likelihood of working after transplant (subhazard ratio compared to private insurance: 0.55; 95% confidence interval: 0.32, 0.95; P = .032). Employment was rare after heart transplantation for congenital heart disease, and was significantly less common than in the broader population of adults with congenital heart disease. Differences in return to work were primarily related to pretransplant employment and the use of public insurance, rather than clinical characteristics. © 2017 Wiley Periodicals, Inc.

  15. Histone methylations in heart development, congenital and adult heart diseases.

    PubMed

    Zhang, Qing-Jun; Liu, Zhi-Ping

    2015-01-01

    Heart development comprises myocyte specification, differentiation and cardiac morphogenesis. These processes are regulated by a group of core cardiac transcription factors in a coordinated temporal and spatial manner. Histone methylation is an emerging epigenetic mechanism for regulating gene transcription. Interplay among cardiac transcription factors and histone lysine modifiers plays important role in heart development. Aberrant expression and mutation of the histone lysine modifiers during development and in adult life can cause either embryonic lethality or congenital heart diseases, and influences the response of adult hearts to pathological stresses. In this review, we describe current body of literature on the role of several common histone methylations and their modifying enzymes in heart development, congenital and adult heart diseases.

  16. Cervical spinal canal narrowing in idiopathic syringomyelia.

    PubMed

    Struck, Aaron F; Carr, Carrie M; Shah, Vinil; Hesselink, John R; Haughton, Victor M

    2016-08-01

    The cervical spine in Chiari I patient with syringomyelia has significantly different anteroposterior diameters than it does in Chiari I patients without syringomyelia. We tested the hypothesis that patients with idiopathic syringomyelia (IS) also have abnormal cervical spinal canal diameters. The finding in both groups may relate to the pathogenesis of syringomyelia. Local institutional review boards approved this retrospective study. Patients with IS were compared to age-matched controls with normal sagittal spine MR. All subjects had T1-weighted spin-echo (500/20) and T2-weighted fast spin-echo (2000/90) sagittal cervical spine images at 1.5 T. Readers blinded to demographic data and study hypothesis measured anteroposterior diameters at each cervical level. The spinal canal diameters were compared with a Mann-Whitney U test. The overall difference was assessed with a Friedman test. Seventeen subjects were read by two reviewers to assess inter-rater reliability. Fifty IS patients with 50 age-matched controls were studied. IS subjects had one or more syrinxes varying from 1 to 19 spinal segments. Spinal canal diameters narrowed from C1 to C3 and then enlarged from C5 to C7 in both groups. Diameters from C2 to C4 were narrower in the IS group (p < 0.005) than in controls. The ratio of the C3 to the C7 diameters was also smaller (p = 0.004) in IS than controls. Collectively, the spinal canal diameters in the IS were significantly different from controls (Friedman test p < 0.0001). Patients with IS have abnormally narrow upper and mid cervical spinal canal diameters and greater positive tapering between C3 and C7.

  17. High Interfacial Barriers at Narrow Carbon Nanotube-Water Interfaces.

    PubMed

    Varanasi, Srinivasa Rao; Subramanian, Yashonath; Bhatia, Suresh K

    2018-06-26

    Water displays anomalous fast diffusion in narrow carbon nanotubes (CNTs), a behavior that has been reproduced in both experimental and simulation studies. However, little is reported on the effect of bulk water-CNT interfaces, which is critical to exploiting the fast transport of water across narrow carbon nanotubes in actual applications. Using molecular dynamics simulations, we investigate here the effect of such interfaces on the transport of water across arm-chair CNTs of different diameters. Our results demonstrate that diffusion of water is significantly retarded in narrow CNTs due to bulk regions near the pore entrance. The slowdown of dynamics can be attributed to the presence of large energy barriers at bulk water-CNT interfaces. The presence of such intense barriers at the bulk-CNT interface arises due to the entropy contrast between the bulk and confined regions, with water molecules undergoing high translational and rotational entropy gain on entering from the bulk to the CNT interior. The intensity of such energy barriers decreases with increase in CNT diameter. These results are very important for emerging technological applications of CNTs and other nanoscale materials, such as in nanofluidics, water purification, nanofiltration, and desalination, as well as for biological transport processes.

  18. Photonic bandgap narrowing in conical hollow core Bragg fibers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ozturk, Fahri Emre; Yildirim, Adem; Kanik, Mehmet

    2014-08-18

    We report the photonic bandgap engineering of Bragg fibers by controlling the thickness profile of the fiber during the thermal drawing. Conical hollow core Bragg fibers were produced by thermal drawing under a rapidly alternating load, which was applied by introducing steep changes to the fiber drawing speed. In conventional cylindrical Bragg fibers, light is guided by omnidirectional reflections from interior dielectric mirrors with a single quarter wave stack period. In conical fibers, the diameter reduction introduced a gradient of the quarter wave stack period along the length of the fiber. Therefore, the light guided within the fiber encountered slightlymore » smaller dielectric layer thicknesses at each reflection, resulting in a progressive blueshift of the reflectance spectrum. As the reflectance spectrum shifts, longer wavelengths of the initial bandgap cease to be omnidirectionally reflected and exit through the cladding, which narrows the photonic bandgap. A narrow transmission bandwidth is particularly desirable in hollow waveguide mid-infrared sensing schemes, where broadband light is coupled to the fiber and the analyte vapor is introduced into the hollow core to measure infrared absorption. We carried out sensing simulations using the absorption spectrum of isopropyl alcohol vapor to demonstrate the importance of narrow bandgap fibers in chemical sensing applications.« less

  19. High prevalence of narrow angles among Filipino-American patients.

    PubMed

    Seider, Michael I; Sáles, Christopher S; Lee, Roland Y; Agadzi, Anthony K; Porco, Travis C; Weinreb, Robert N; Lin, Shan C

    2011-03-01

    To determine the prevalence of gonioscopically narrow anterior chamber angles in a Filipino-American clinic population. The records of 122 consecutive, new, self-declared Filipino-American patients examined in a comprehensive ophthalmology clinic in Vallejo, California were reviewed retrospectively. After exclusion, 222 eyes from 112 patients remained for analysis. Data were collected for anterior chamber angle grade as determined by gonioscopy (Shaffer system), age, sex, manifest refraction (spherical equivalent), intraocular pressure, and cup-to-disk ratio. Data from both eyes of patients were included and modeled using standard linear mixed-effects regression. As a comparison, data were also collected from a group of 30 consecutive White patients from the same clinic. After exclusion, 50 eyes from 25 White patients remained for comparison. At least 1 eye of 24% of Filipino-American patients had a narrow anterior chamber angle (Shaffer grade ≤ 2). Filipino-American angle grade significantly decreased with increasingly hyperopic refraction (P=0.007) and larger cup-to-disk ratio (P=0.038). Filipino-American women had significantly decreased angle grades compared with men (P=0.028), but angle grade did not vary by intraocular pressure or age (all, P≥ 0.059). Narrow anterior chamber angles are highly prevalent in Filipino-American patients in our clinic population.

  20. The Radio-Loud Narrow-Line Quasar SDSS J172206.03+565451.6

    NASA Astrophysics Data System (ADS)

    Komossa, Stefanie; Voges, Wolfgang; Adorf, Hans-Martin; Xu, Dawei; Mathur, Smita; Anderson, Scott F.

    2006-03-01

    We report identification of the radio-loud narrow-line quasar SDSS J172206.03+565451.6, which we found in the course of a search for radio-loud narrow-line active galactic nuclei (AGNs). SDSS J172206.03+565451.6 is only about the fourth securely identified radio-loud narrow-line quasar and the second-most radio loud, with a radio index R1.4~100-700. Its black hole mass, MBH~=(2-3)×107 Msolar estimated from Hβ line width and 5100 Å luminosity, is unusually small given its radio loudness, and the combination of mass and radio index puts SDSS J172206.03+565451.6 in a scarcely populated region of MBH-R diagrams. SDSS J172206.03+565451.6 is a classical narrow-line Seyfert 1-type object with FWHMHβ~=1490 km s-1, an intensity ratio of [O III]/Hβ~=0.7, and Fe II emission complexes with Fe II λ4570/Hβ~=0.7. The ionization parameter of its narrow-line region, estimated from the line ratio [O II]/[O III], is similar to Seyferts, and its high ratio of [Ne V]/[Ne III] indicates a strong EUV-to-soft X-ray excess. We advertise the combined usage of [O II]/[O III] and [Ne V]/[Ne III] diagrams as a useful diagnostic tool to estimate ionization parameters and to constrain the EUV-soft X-ray continuum shape relatively independently from other parameters.

  1. Timing of left heart base descent in dogs with dilated cardiomyopathy and normal dogs.

    PubMed

    Simpson, Kerry E; Devine, Bryan C; Woolley, Richard; Corcoran, Brendan M; French, Anne T

    2008-01-01

    The identification and assessment of myocardial failure in canine idiopathic dilated cardiomyopathy (DCM) is achieved using a variety of two-dimensional and Doppler echocardiographic techniques. More recently, the availability of tissue Doppler imaging (TDI) has raised the potential for development of new ways of more accurately identifying a disease phenotype. Nevertheless, TDI has not been universally adapted to veterinary clinical cardiology primarily because of the lack of information on its utility in diagnosis. We assessed the application of timing of left heart base descent using TDI in the identification of differences between DCM and normal dogs. The times from the onset of the QRS complex on a simultaneously recorded electrocardiograph to the onset (Q--S'), peak (Q--peak S'), and end (Q--end S') of the systolic velocity peak were measured in the interventricular septum (IVS) and the left ventricular free wall. The duration of S' was also calculated. The Q--S' (FW), Q--end S' (FW), and duration S' (FW) were correlated with ejection fraction in the diseased group (P < 0.05). In addition, Q--S', Q--peak S', Q--end S', and the peak S' velocity were prolonged in the diseased dogs at both the free wall and in the IVS (P < 0.01). The duration of S' was unaffected by disease status. These findings provide insight into the electromechanical uncoupling that occurs in canine DCM and identifies new TDI parameters that can be added to the range of Doppler and echocardiographic parameters used for detecting myocardial failure in the dog.

  2. Narrow beam neutron dosimetry.

    PubMed

    Ferenci, M Sutton

    2004-01-01

    Organ and effective doses have been estimated for male and female anthropomorphic mathematical models exposed to monoenergetic narrow beams of neutrons with energies from 10(-11) to 1000 MeV. Calculations were performed for anterior-posterior, posterior-anterior, left-lateral and right-lateral irradiation geometries. The beam diameter used in the calculations was 7.62 cm and the phantoms were irradiated at a height of 1 m above the ground. This geometry was chosen to simulate an accidental scenario (a worker walking through the beam) at Flight Path 30 Left (FP30L) of the Weapons Neutron Research (WNR) Facility at Los Alamos National Laboratory. The calculations were carried out using the Monte Carlo transport code MCNPX 2.5c.

  3. Heart failure.

    PubMed

    Metra, Marco; Teerlink, John R

    2017-10-28

    Heart failure is common in adults, accounting for substantial morbidity and mortality worldwide. Its prevalence is increasing because of ageing of the population and improved treatment of acute cardiovascular events, despite the efficacy of many therapies for patients with heart failure with reduced ejection fraction, such as angiotensin converting enzyme (ACE) inhibitors, angiotensin receptor blockers (ARBs), β blockers, and mineralocorticoid receptor antagonists, and advanced device therapies. Combined angiotensin receptor blocker neprilysin inhibitors (ARNIs) have been associated with improvements in hospital admissions and mortality from heart failure compared with enalapril, and guidelines now recommend substitution of ACE inhibitors or ARBs with ARNIs in appropriate patients. Improved safety of left ventricular assist devices means that these are becoming more commonly used in patients with severe symptoms. Antidiabetic therapies might further improve outcomes in patients with heart failure. New drugs with novel mechanisms of action, such as cardiac myosin activators, are under investigation for patients with heart failure with reduced left ventricular ejection fraction. Heart failure with preserved ejection fraction is a heterogeneous disorder that remains incompletely understood and will continue to increase in prevalence with the ageing population. Although some data suggest that spironolactone might improve outcomes in these patients, no therapy has conclusively shown a significant effect. Hopefully, future studies will address these unmet needs for patients with heart failure. Admissions for acute heart failure continue to increase but, to date, no new therapies have improved clinical outcomes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Dynamic film thickness between bubbles and wall in a narrow channel

    NASA Astrophysics Data System (ADS)

    Ito, Daisuke; Damsohn, Manuel; Prasser, Horst-Michael; Aritomi, Masanori

    2011-09-01

    The present paper describes a novel technique to characterize the behavior of the liquid film between gas bubbles and the wall in a narrow channel. The method is based on the electrical conductance. Two liquid film sensors are installed on both opposite walls in a narrow rectangular channel. The liquid film thickness underneath the gas bubbles is recorded by the first sensor, while the void fraction information is obtained by measuring the conductance between the pair of opposite sensors. Both measurements are taken on a large two-dimensional domain and with a high speed. This makes it possible to obtain the two-dimensional distribution of the dynamic liquid film between the bubbles and the wall. In this study, this method was applied to an air-water flow ranging from bubbly to churn regimes in the narrow channel with a gap width of 1.5 mm.

  5. Potential implications of the helical heart in congenital heart defects.

    PubMed

    Corno, Antonio F; Kocica, Mladen J

    2007-01-01

    The anatomic and functional observations made by Francisco Torrent-Guasp, in particular his discovery of the helical ventricular myocardial band (HVMB), have challenged what has been taught to cardiologists and cardiac surgeons over centuries. A literature debate is ongoing, with interdependent articles and comments from supporters and critics. Adequate understanding of heart structure and function is obviously indispensable for the decision-making process in congenital heart defects. The HVMB described by Torrent-Guasp and the potential impact on the understanding and treatment of congenital heart defects has been analyzed in the following settings: embryology, ventriculo-arterial discordance (transposition of great arteries), Ebstein's anomaly, pulmonary valve regurgitation after repair of tetralogy of Fallot, Ross operation, and other congenital heart defects. The common structural spiral feature is only one of the elements responsible for the functional interaction of right and left ventricles, and understanding the form/function relationship in congenital heart defects is more difficult than for acquired heart disease because of the variety and complexity of congenital heart defects. Individuals involved in the care of patients with congenital heart defects have to be stimulated to consider further investigations and alternative surgical strategies.

  6. Million Hearts: Key to Collaboration to Reduce Heart Disease

    ERIC Educational Resources Information Center

    Brinkman, Patricia

    2016-01-01

    Extension has taught successful classes to address heart disease, yet heart disease remains the number one killer in the United States. The U.S. government's Million Hearts initiative seeks collaboration among colleges, local and state health departments, Extension and other organizations, and medical providers in imparting a consistent message…

  7. Method for shaping and aiming narrow beams. [sonar mapping and target identification

    NASA Technical Reports Server (NTRS)

    Heyser, R. C. (Inventor)

    1981-01-01

    A sonar method and apparatus is discribed which utilizes a linear frequency chirp in a transmitter/receiver having a correlator to synthesize a narrow beamwidth pattern from otherwise broadbeam transducers when there is relative velocity between the transmitter/receiver and the target. The chirp is so produced in a generator in bandwidth, B, and time, T, as to produce a time bandwidth product, TB, that is increased for a narrower angle. A replica of the chirp produced in a generator is time delayed and Doppler shifted for use as a reference in the receiver for correlation of received chirps from targets. This reference is Doppler shifted to select targets preferentially, thereby to not only synthesize a narrow beam but also aim the beam in azimuth and elevation.

  8. Pediatric heart surgery - discharge

    MedlinePlus

    ... of the aorta repair - discharge; Heart surgery for children - discharge; Atrial septal defect repair - discharge; Ventricular septal ... discharge; Acquired heart disease - discharge; Heart valve surgery - ... Heart surgery - pediatric - discharge; Heart transplant - pediatric - ...

  9. Wine and heart health

    MedlinePlus

    Health and wine; Wine and heart disease; Preventing heart disease - wine; Preventing heart disease - alcohol ... more often just to lower your risk of heart disease. Heavier drinking can harm the heart and ...

  10. Auxiliary total artificial heart: A compact electromechanical artificial heart working simultaneously with the natural heart.

    PubMed

    Andrade, A; Nicolosi, D; Lucchi, J; Biscegli, J; Arruda, A C; Ohashi, Y; Mueller, J; Tayama, E; Glueck, J; Nosé, Y

    1999-09-01

    Leading international institutions are designing and developing various types of ventricular assist devices (VAD) and total artificial hearts (TAH). Some of the commercially available pulsatile VADs are not readily implantable into the thoracic cavity of smaller size patients because of size limitation. The majority of the TAH dimensions requires the removal of the patients' native heart. A miniaturized artificial heart, the auxiliary total artificial heart (ATAH), is being developed in these authors' laboratories. This device is an electromechanically driven ATAH using a brushless direct current (DC) motor fixed in a center metallic piece. This pusher plate-type ATAH control is based on Frank-Starling's law. The beating frequency is regulated through the change of the left preload, assisting the native heart in obtaining adequate blood flow. With the miniaturization of this pump, the average sized patient can have the surgical implantation procedure in the right thoracic cavity without removing the native heart. The left and right stroke volumes are 35 and 32 ml, respectively. In vitro tests were conducted, and the performance curves demonstrate that the ATAH produces 5 L/min of cardiac output at 180 bpm (10 mmHg of left inlet mean pressure and 100 mm Hg of left outlet mean pressure). Taking into account that this ATAH is working along with the native heart, this output is more than satisfactory for such a device.

  11. Enhanced tunable narrow-band THz emission from laser-modulated electron beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiang, D.; Stupakov, G.; /SLAC

    2009-06-19

    We propose and analyze a scheme to generate enhanced narrow-band terahertz (THz) radiation through down-conversion of the frequency of optical lasers using laser-modulated electron beams. In the scheme the electron beam is first energy modulated by two lasers with wave numbers k{sub 1} and k2, respectively. After passing through a dispersion section, the energy modulation is converted to density modulation. Due to the nonlinear conversion process, the beam will have density modulation at wave number k = nk{sub 1} + mk{sub 2}, where n and m are positive or negative integers. By properly choosing the parameters for the lasers andmore » dispersion section, one can generate density modulation at THz frequency in the beam using optical lasers. This density-modulated beam can be used to generate powerful narrow-band THz radiation. Since the THz radiation is in tight synchronization with the lasers, it should provide a high temporal resolution for the optical-pump THz-probe experiments. The central frequency of the THz radiation can be easily tuned by varying the wavelength of the two lasers and the energy chirp of the electron beam. The proposed scheme is in principle able to generate intense narrow-band THz radiation covering the whole THz range and offers a promising way towards the tunable intense narrow-band THz sources.« less

  12. Technology Advances to Improve Response to Cardiac Resynchronization Therapy: What Clinicians Should Know.

    PubMed

    Auricchio, Angelo; Heggermont, Ward A

    2018-06-01

    Cardiac resynchronization therapy (CRT) is a well-established treatment for symptomatic heart failure patients with reduced left ventricular ejection fraction, prolonged QRS duration, and abnormal QRS morphology. The ultimate goals of modern CRT are to improve the proportion of patients responding to CRT and to maximize the response to CRT in patients who do respond. While the rate of CRT nonresponders has moderately but progressively decreased over the last 20 years, mostly in patients with left bundle branch block, in patients without left bundle branch block the response rate is almost unchanged. A number of technological advances have already contributed to achieve some of the objectives of modern CRT. They include novel lead design (the left ventricular quadripolar lead, and multipoint pacing), or the possibility to go beyond conventional delivery of CRT (left ventricular endocardial pacing, His bundle pacing). Furthermore, to improve CRT response, a triad of actions is paramount: reducing the burden of atrial fibrillation, reducing the number of appropriate and inappropriate interventions, and adequately predicting heart failure episodes. As in other fields of cardiology, technology and innovations for CRT delivery have been at the forefront in transforming-improving-patient care; therefore, these innovations are discussed in this review. Copyright © 2018 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  13. Precise measurement of ultra-narrow laser linewidths using the strong coherent envelope

    NASA Astrophysics Data System (ADS)

    Huang, Shihong; Zhu, Tao; Liu, Min; Huang, Wei

    2017-02-01

    Laser linewidth narrowing down to kHz or even Hz is an important topic in areas like clock synchronization technology, laser radars, quantum optics, and high-precision detection. Conventional decoherence measurement methods like delayed self-heterodyne/homodyne interferometry cannot measure such narrow linewidths accurately. This is because a broadening of the Gaussian spectrum, which hides the laser’s intrinsic Lorentzian linewidth, cannot be avoided. Here, we introduce a new method using the strong coherent envelope to characterize the laser’s intrinsic linewidth through self-coherent detection. This method can eliminate the effect of the broadened Gaussian spectrum induced by the 1/f frequency noise. We analyze, in detail, the relationship between intrinsic laser linewidth, contrast difference with the second peak and the second trough (CDSPST) of the strong coherent envelope, and the length of the delaying fiber. The correct length for the delaying fiber can be chosen by combining the estimated laser linewidth (Δfest) with a specific CDSPST (ΔS) to obtain the accurate laser linewidth (Δf). Our results indicate that this method can be used as an accurate detection tool for measurements of narrow or super-narrow linewidths.

  14. Heart Disease and Stroke

    MedlinePlus

    ... receive Heart Disease and Stroke email updates Submit Heart Disease and Stroke Heart disease and stroke are important ... Stroke Stroke symptoms Stroke risk factors View more Heart Disease and Stroke resources Related information Heart-healthy eating ...

  15. Passive fetal heart rate monitoring apparatus and method with enhanced fetal heart beat discrimination

    NASA Technical Reports Server (NTRS)

    Zahorian, Stephen A. (Inventor); Livingston, David L. (Inventor); Pretlow, III, Robert A. (Inventor)

    1996-01-01

    An apparatus for acquiring signals emitted by a fetus, identifying fetal heart beats and determining a fetal heart rate. Multiple sensor signals are outputted by a passive fetal heart rate monitoring sensor. Multiple parallel nonlinear filters filter these multiple sensor signals to identify fetal heart beats in the signal data. A processor determines a fetal heart rate based on these identified fetal heart beats. The processor includes the use of a figure of merit weighting of heart rate estimates based on the identified heart beats from each filter for each signal. The fetal heart rate thus determined is outputted to a display, storage, or communications channel. A method for enhanced fetal heart beat discrimination includes acquiring signals from a fetus, identifying fetal heart beats from the signals by multiple parallel nonlinear filtering, and determining a fetal heart rate based on the identified fetal heart beats. A figure of merit operation in this method provides for weighting a plurality of fetal heart rate estimates based on the identified fetal heart beats and selecting the highest ranking fetal heart rate estimate.

  16. Passive fetal heart rate monitoring apparatus and method with enhanced fetal heart beat discrimination

    NASA Technical Reports Server (NTRS)

    Zahorian, Stephen A. (Inventor); Livingston, David L. (Inventor); Pretlow, Robert A., III (Inventor)

    1994-01-01

    An apparatus for acquiring signals emitted by a fetus, identifying fetal heart beats and determining a fetal heart rate is presented. Multiple sensor signals are outputted by a passive fetal heart rate monitoring sensor. Multiple parallel nonlinear filters filter these multiple sensor signals to identify fetal heart beats in the signal data. A processor determines a fetal heart rate based on these identified fetal heart beats. The processor includes the use of a figure of merit weighting of heart rate estimates based on the identified heart beats from each filter for each signal. The fetal heart rate thus determined is outputted to a display, storage, or communications channel. A method for enhanced fetal heart beat discrimination includes acquiring signals from a fetus, identifying fetal heart beats from the signals by multiple parallel nonlinear filtering, and determining a fetal heart rate based on the identified fetal heart beats. A figure of merit operation in this method provides for weighting a plurality of fetal heart rate estimates based on the identified fetal heart beats and selecting the highest ranking fetal heart rate estimate.

  17. Six-Year Outcome of Subjects Without Overt Heart Disease With an Early Repolarization/J Wave Electrocardiographic Pattern.

    PubMed

    Lanza, Gaetano Antonio; Argirò, Alessia; Mollo, Roberto; De Vita, Antonio; Spera, Francesco; Golino, Michele; Rota, Elisabetta; Filice, Monica; Crea, Filippo

    2017-12-01

    "Early repolarization" (ER) is a frequent finding at standard electrocardiogram (ECG). In this study we assessed whether ER is associated with an increased risk of events, as recently suggested by some studies. We prospectively enrolled 4,176 consecutive subjects without any heart disease who underwent routine ECG recording. ER was diagnosed in case of typical concave ST-segment elevation ≥0.1 mV; a J wave was diagnosed when the QRS showed a notch or a slur in its terminal part. In this study we compared the 6-year outcome of all 687 subjects with ER/J wave and 687 matched subjects without ER/J wave (controls). Both groups included 335 males and 352 females, and age was 48.8 ± 18 years. Overall, 145 deaths occurred (11%), only 11 of which attributed to cardiac causes. No sudden death was reported. Cardiac deaths occurred in 5 (0.8%) and 6 (0.9%) ER/J wave subjects and controls, respectively (odds ratio [OR] 0.85, 95% confidence interval [CI] 0.26 to 2.80, p = 0.79). Both ER (OR 1.68, 95% CI 0.21 to 13.3, p = 0.62) and J wave (OR 0.91, 95% CI 0.28 to 3.00, p = 0.88) showed no association with cardiac death. Total mortality was 11.5% in the ER/J wave group and 10.6% in the control group (OR 1.10, 95% CI 0.78 to 1.56, p = 0.58). Both ER (OR 0.44, 95% CI 0.16 to 1.24, p = 0.12) and J wave (OR 1.20, 95% CI 0.85 to 1.70, p = 0.30) showed also no association with all-cause death. In subjects without any evidence of heart disease, we found no significant association of ER/J wave with the risk of cardiac, as well as all-cause, death at medium-term follow-up. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. ECG parameters predict left ventricular conduction delay in patients with left ventricular dysfunction.

    PubMed

    Pastore, Gianni; Maines, Massimiliano; Marcantoni, Lina; Zanon, Francesco; Noventa, Franco; Corbucci, Giorgio; Baracca, Enrico; Aggio, Silvio; Picariello, Claudio; Lanza, Daniela; Rigatelli, Gianluca; Carraro, Mauro; Roncon, Loris; Barold, S Serge

    2016-12-01

    Estimating left ventricular electrical delay (Q-LV) from a 12-lead ECG may be important in evaluating cardiac resynchronization therapy (CRT). The purpose of this study was to assess the impact of Q-LV interval on ECG configuration. One hundred ninety-two consecutive patients undergoing CRT implantation were divided electrocardiographically into 3 groups: left bundle branch block (LBBB), right bundle branch block (RBBB), and nonspecific intraventricular conduction delay (IVCD). The IVCD group was further subdivided into 81 patients with left (L)-IVCD and 15 patients with right (R)-IVCD (resembling RBBB, but without S wave in leads I and aVL). The Q-LV interval in the different groups and the relationship between ECG parameters and the maximum Q-LV interval were analyzed. Patients with LBBB presented a long Q-LV interval (147.7 ± 14.6 ms, all exceeding cutoff value of 110 ms), whereas RBBB patients presented a very short Q-LV interval (75.2 ± 16.3 ms, all <110 ms). Patients with an IVCD displayed a wide range of Q-LV intervals. In L-IVCD, mid-QRS notching/slurring showed the strongest correlation with a longer Q-LV interval, followed, in decreasing order, by QRS duration >150 ms and intrinsicoid deflection >60 ms. Isolated mid-QRS notching/slurring predicted Q-LV interval >110 ms in 68% of patients. The R-IVCD group presented an unexpectedly longer Q-LV interval (127.0 ± 12.5 ms; 13/15 patients had Q-LV >110 ms). Patients with LBBB have a very prolonged Q-LV interval. Mid-QRS notching in lateral leads strongly predicts a longer Q-LV interval in L-IVCD patients. Patients with R-IVCD constitute a subgroup of patients with a long Q-LV interval. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  19. Electrocardiogram abnormalities and coronary calcification in postmenopausal women.

    PubMed

    Sabour, Siamak; Grobbee, Diederick; Rutten, Annemarieke; Prokop, Mathias; Bartelink, Marie-Louise; van der Schouw, Yvonne; Bots, Michiel

    2010-01-01

    An electrocardiogram (ECG) can provide information on subclinical myocardial damage. The presence, and more importantly, the quantity of coronary artery calcification (CAC), relates well with the overall severity of the atherosclerotic process. A strong relation has been demonstrated between coronary calcium burden and the incidence of myocardial infarction, a relation independent of age. The aim of this study was to assess the relation of left ventricular hypertrophy (LVH) and ECG abnormalities with CAC. The study population comprised 566 postmenopausal women selected from a population-based cohort study. Information on LVH and repolarization abnormalities (T-axis and QRS-T angle) was obtained using electrocardiography. Modular ECG Analysis System (MEANS) was used to assess ECG abnormalities. The women underwent a multi detector-row computed tomography (MDCT) scan (Philips Mx 8000 IDT 16) to assess CAC. The Agatston score was used to quantify CAC; scores greater than zero were considered as the presence of coronary calcium. Logistic regression was used to assess the relation of ECG abnormality with coronary calcification. LVH was found in 2.7% (n = 15) of the women. The prevalence of T-axis abnormality was 6% (n = 34), whereas 8.5% (n = 48) had a QRS-T angle abnormality. CAC was found in 62% of the women. Compared to women with a normal T-axis, women with borderline or abnormal T-axes were 3.8 fold more likely to have CAC (95% CI: 1.4-10.2). Similarly, compared to women with a normal QRS-T angle, in women with borderline or abnormal QRS-T angle, CAC was 2.0 fold more likely to be present (95% CI: 1.0-4.1). Among women with ECG abnormalities reflecting subclinical ischemia, CAC is commonly found and may in part explain the increased coronary heart disease risk associated with these ECG abnormalities.

  20. Electrocardiogram Abnormalities and Coronary Calcification in Postmenopausal Women

    PubMed Central

    Sabour, Siamak; Grobbee, Diederick; Rutten, Annemarieke; Prokop, Mathias; Bartelink, Marie-Louise; van der Schouw, Yvonne; Bots, Michiel

    2010-01-01

    Background: An electrocardiogram (ECG) can provide information on subclinical myocardial damage. The presence, and more importantly, the quantity of coronary artery calcification (CAC), relates well with the overall severity of the atherosclerotic process. A strong relation has been demonstrated between coronary calcium burden and the incidence of myocardial infarction, a relation independent of age. The aim of this study was to assess the relation of left ventricular hypertrophy (LVH) and ECG abnormalities with CAC. Methods: The study population comprised 566 postmenopausal women selected from a population-based cohort study. Information on LVH and repolarization abnormalities (T-axis and QRS-T angle) was obtained using electrocardiography. Modular ECG Analysis System (MEANS) was used to assess ECG abnormalities. The women underwent a multi detector-row computed tomography (MDCT) scan (Philips Mx 8000 IDT 16) to assess CAC. The Agatston score was used to quantify CAC; scores greater than zero were considered as the presence of coronary calcium. Logistic regression was used to assess the relation of ECG abnormality with coronary calcification. Results: LVH was found in 2.7% (n = 15) of the women. The prevalence of T-axis abnormality was 6% (n = 34), whereas 8.5% (n = 48) had a QRS-T angle abnormality. CAC was found in 62% of the women. Compared to women with a normal T-axis, women with borderline or abnormal T-axes were 3.8 fold more likely to have CAC (95% CI: 1.4–10.2). Similarly, compared to women with a normal QRS-T angle, in women with borderline or abnormal QRS-T angle, CAC was 2.0 fold more likely to be present (95% CI: 1.0–4.1). Conclusion: Among women with ECG abnormalities reflecting subclinical ischemia, CAC is commonly found and may in part explain the increased coronary heart disease risk associated with these ECG abnormalities. PMID:23074563